WorldWideScience

Sample records for release system consisting

  1. Maintaining consistency in distributed systems

    Science.gov (United States)

    Birman, Kenneth P.

    1991-01-01

    In systems designed as assemblies of independently developed components, concurrent access to data or data structures normally arises within individual programs, and is controlled using mutual exclusion constructs, such as semaphores and monitors. Where data is persistent and/or sets of operation are related to one another, transactions or linearizability may be more appropriate. Systems that incorporate cooperative styles of distributed execution often replicate or distribute data within groups of components. In these cases, group oriented consistency properties must be maintained, and tools based on the virtual synchrony execution model greatly simplify the task confronting an application developer. All three styles of distributed computing are likely to be seen in future systems - often, within the same application. This leads us to propose an integrated approach that permits applications that use virtual synchrony with concurrent objects that respect a linearizability constraint, and vice versa. Transactional subsystems are treated as a special case of linearizability.

  2. Self-consistent nuclear energy systems

    International Nuclear Information System (INIS)

    Shimizu, A.; Fujiie, Y.

    1995-01-01

    A concept of self-consistent energy systems (SCNES) has been proposed as an ultimate goal of the nuclear energy system in the coming centuries. SCNES should realize a stable and unlimited energy supply without endangering the human race and the global environment. It is defined as a system that realizes at least the following four objectives simultaneously: (a) energy generation -attain high efficiency in the utilization of fission energy; (b) fuel production - secure inexhaustible energy source: breeding of fissile material with the breeding ratio greater than one and complete burning of transuranium through recycling; (c) burning of radionuclides - zero release of radionuclides from the system: complete burning of transuranium and elimination of radioactive fission products by neutron capture reactions through recycling; (d) system safety - achieve system safety both for the public and experts: eliminate criticality-related safety issues by using natural laws and simple logic. This paper describes the concept of SCNES and discusses the feasibility of the system. Both ''neutron balance'' and ''energbalance'' of the system are introduced as the necessary conditions to be satisfied at least by SCNES. Evaluations made so far indicate that both the neutron balance and the energy balance can be realized by fast reactors but not by thermal reactors. Concerning the system safety, two safety concepts: ''self controllability'' and ''self-terminability'' are introduced to eliminate the criticality-related safety issues in fast reactors. (author)

  3. Sticky continuous processes have consistent price systems

    DEFF Research Database (Denmark)

    Bender, Christian; Pakkanen, Mikko; Sayit, Hasanjan

    Under proportional transaction costs, a price process is said to have a consistent price system, if there is a semimartingale with an equivalent martingale measure that evolves within the bid-ask spread. We show that a continuous, multi-asset price process has a consistent price system, under...

  4. On the existence of consistent price systems

    DEFF Research Database (Denmark)

    Bayraktar, Erhan; Pakkanen, Mikko S.; Sayit, Hasanjan

    2014-01-01

    We formulate a sufficient condition for the existence of a consistent price system (CPS), which is weaker than the conditional full support condition (CFS). We use the new condition to show the existence of CPSs for certain processes that fail to have the CFS property. In particular this condition...

  5. Consistent thermodynamic properties of lipids systems

    DEFF Research Database (Denmark)

    Cunico, Larissa; Ceriani, Roberta; Sarup, Bent

    different pressures, with azeotrope behavior observed. Available thermodynamic consistency tests for TPx data were applied before performing parameter regressions for Wilson, NRTL, UNIQUAC and original UNIFAC models. The relevance of enlarging experimental databank of lipids systems data in order to improve......Physical and thermodynamic properties of pure components and their mixtures are the basic requirement for process design, simulation, and optimization. In the case of lipids, our previous works[1-3] have indicated a lack of experimental data for pure components and also for their mixtures...... the performance of predictive thermodynamic models was confirmed in this work by analyzing the calculated values of original UNIFAC model. For solid-liquid equilibrium (SLE) data, new consistency tests have been developed [2]. Some of the developed tests were based in the quality tests proposed for VLE data...

  6. Do Health Systems Have Consistent Performance Across Locations and Is Consistency Associated With Higher Performance?

    Science.gov (United States)

    Crespin, Daniel J; Christianson, Jon B; McCullough, Jeffrey S; Finch, Michael D

    This study addresses whether health systems have consistent diabetes care performance across their ambulatory clinics and whether increasing consistency is associated with improvements in clinic performance. Study data included 2007 to 2013 diabetes care intermediate outcome measures for 661 ambulatory clinics in Minnesota and bordering states. Health systems provided more consistent performance, as measured by the standard deviation of performance for clinics in a system, relative to propensity score-matched proxy systems created for comparison purposes. No evidence was found that improvements in consistency were associated with higher clinic performance. The combination of high performance and consistent care is likely to enhance a health system's brand reputation, allowing it to better mitigate the financial risks of consumers seeking care outside the organization. These results suggest that larger health systems are most likely to deliver the combination of consistent and high-performance care. Future research should explore the mechanisms that drive consistent care within health systems.

  7. A Consistent System for Coding Laboratory Samples

    Science.gov (United States)

    Sih, John C.

    1996-07-01

    A formal laboratory coding system is presented to keep track of laboratory samples. Preliminary useful information regarding the sample (origin and history) is gained without consulting a research notebook. Since this system uses and retains the same research notebook page number for each new experiment (reaction), finding and distinguishing products (samples) of the same or different reactions becomes an easy task. Using this system multiple products generated from a single reaction can be identified and classified in a uniform fashion. Samples can be stored and filed according to stage and degree of purification, e.g. crude reaction mixtures, recrystallized samples, chromatographed or distilled products.

  8. Self-consistent phonons in disordered systems

    International Nuclear Information System (INIS)

    Das, M.P.

    1990-01-01

    The time is now ripe for the development of a microscopic theory of the disordered systems in the context of phonons. The adiabatic approximation has helped to separate the electronic motion from that of the ions. In the microscopic dielectric formulation we have been able to obtain the interatomic forces for ordered systems by incorporating the effect of the electronic motion. The nature of the electronic states in disordered systems is now better understood with realistic coherent potential approximation calculations. Therefore, it will not be too ambitious to construct an average dielectric function for a disordered system. Then we can obtain a properly screened pair potential in terms of this dielectric function. In view of the availability of super fast computers, the development of the microscopic theories are expected to get a new direction. (author). 36 refs

  9. Techniques for Reducing Consistency-Related Communication in Distributed Shared Memory System

    OpenAIRE

    Zwaenepoel, W; Bennett, J.K.; Carter, J.B.

    1995-01-01

    Distributed shared memory 8DSM) is an abstraction of shared memory on a distributed memory machine. Hardware DSM systems support this abstraction at the architecture level; software DSM systems support the abstraction within the runtime system. One of the key problems in building an efficient software DSM system is to reduce the amount of communication needed to keep the distributed memories consistent. In this paper we present four techniques for doing so: 1) software release consistency; 2)...

  10. Liver cancer cells: targeting and prolonged-release drug carriers consisting of mesoporous silica nanoparticles and alginate microspheres.

    Science.gov (United States)

    Liao, Yu-Te; Liu, Chia-Hung; Yu, Jiashing; Wu, Kevin C-W

    2014-01-01

    A new microsphere consisting of inorganic mesoporous silica nanoparticles (MSNs) and organic alginate (denoted as MSN@Alg) was successfully synthesized by air-dynamic atomization and applied to the intracellular drug delivery systems (DDS) of liver cancer cells with sustained release and specific targeting properties. MSN@Alg microspheres have the advantages of MSN and alginate, where MSN provides a large surface area for high drug loading and alginate provides excellent biocompatibility and COOH functionality for specific targeting. Rhodamine 6G was used as a model drug, and the sustained release behavior of the rhodamine 6G-loaded MSN@Alg microspheres can be prolonged up to 20 days. For targeting therapy, the anticancer drug doxorubicin was loaded into MSN@Alg microspheres, and the (lysine)4-tyrosine-arginine-glycine-aspartic acid (K4YRGD) peptide was functionalized onto the surface of MSN@Alg for targeting liver cancer cells, hepatocellular carcinoma (HepG2). The results of the 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT) assay and confocal laser scanning microscopy indicate that the MSN@Alg microspheres were successfully uptaken by HepG2 without apparent cytotoxicity. In addition, the intracellular drug delivery efficiency was greatly enhanced (ie, 3.5-fold) for the arginine-glycine-aspartic acid (RGD)-labeled, doxorubicin-loaded MSN@Alg drug delivery system compared with the non-RGD case. The synthesized MSN@Alg microspheres show great potential as drug vehicles with high biocompatibility, sustained release, and targeting features for future intracellular DDS.

  11. Liver cancer cells: targeting and prolonged-release drug carriers consisting of mesoporous silica nanoparticles and alginate microspheres

    Directory of Open Access Journals (Sweden)

    Liao YT

    2014-06-01

    Full Text Available Yu-Te Liao,1 Chia-Hung Liu,2 Jiashing Yu,1 Kevin C-W Wu1,3 1Department of Chemical Engineering, National Taiwan University, Taipei, Taiwan; 2Department of Urology, Taipei Medical University-Shuang Ho Hospital, New Taipei City, Taiwan; 3Division of Medical Engineering Research, National Health Research Institutes, Zhunan Township, Miaoli County, Taiwan Abstract: A new microsphere consisting of inorganic mesoporous silica nanoparticles (MSNs and organic alginate (denoted as MSN@Alg was successfully synthesized by air-dynamic atomization and applied to the intracellular drug delivery systems (DDS of liver cancer cells with sustained release and specific targeting properties. MSN@Alg microspheres have the advantages of MSN and alginate, where MSN provides a large surface area for high drug loading and alginate provides excellent biocompatibility and COOH functionality for specific targeting. Rhodamine 6G was used as a model drug, and the sustained release behavior of the rhodamine 6G-loaded MSN@Alg microspheres can be prolonged up to 20 days. For targeting therapy, the anticancer drug doxorubicin was loaded into MSN@Alg microspheres, and the (lysine4-tyrosine-arginine-glycine-aspartic acid (K4YRGD peptide was functionalized onto the surface of MSN@Alg for targeting liver cancer cells, hepatocellular carcinoma (HepG2. The results of the 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT assay and confocal laser scanning microscopy indicate that the MSN@Alg microspheres were successfully uptaken by HepG2 without apparent cytotoxicity. In addition, the intracellular drug delivery efficiency was greatly enhanced (ie, 3.5-fold for the arginine-glycine-aspartic acid (RGD-labeled, doxorubicin-loaded MSN@Alg drug delivery system compared with the non-RGD case. The synthesized MSN@Alg microspheres show great potential as drug vehicles with high biocompatibility, sustained release, and targeting features for future intracellular DDS. Keywords

  12. Consistency of a system of equations: What does that mean?

    NARCIS (Netherlands)

    Still, Georg J.; Kern, Walter; Koelewijn, Jaap; Bomhoff, M.J.

    2010-01-01

    The concept of (structural) consistency also called structural solvability is an important basic tool for analyzing the structure of systems of equations. Our aim is to provide a sound and practically relevant meaning to this concept. The implications of consistency are expressed in terms of

  13. An approach to a self-consistent nuclear energy system

    International Nuclear Information System (INIS)

    Fujii-e, Yoichi; Arie, Kazuo; Endo, Hiroshi

    1992-01-01

    A nuclear energy system should provide a stable supply of energy without endangering the environment or humans. If there is fear about exhausting world energy resources, accumulating radionuclides, and nuclear reactor safety, tension is created in human society. Nuclear energy systems of the future should be able to eliminate fear from people's minds. In other words, the whole system, including the nuclear fuel cycle, should be self-consistent. This is the ultimate goal of nuclear energy. If it can be realized, public acceptance of nuclear energy will increase significantly. In a self-consistent nuclear energy system, misunderstandings between experts on nuclear energy and the public should be minimized. The way to achieve this goal is to explain using simple logic. This paper proposes specific targets for self-consistent nuclear energy systems and shows that the fast breeder reactor (FBR) lies on the route to attaining the final goal

  14. Electrosprayed nanoparticle delivery system for controlled release

    Energy Technology Data Exchange (ETDEWEB)

    Eltayeb, Megdi, E-mail: megdi.eltayeb@sustech.edu [Department of Biomedical Engineering, Sudan University of Science and Technology, PO Box 407, Khartoum (Sudan); Stride, Eleanor, E-mail: eleanor.stride@eng.ox.ac.uk [Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building, Headington OX3 7DQ (United Kingdom); Edirisinghe, Mohan, E-mail: m.edirisinghe@ucl.ac.uk [Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE (United Kingdom); Harker, Anthony, E-mail: a.harker@ucl.ac.uk [London Centre for Nanotechnology, Gordon Street, London WC1H 0AH (United Kingdom); Department of Physics & Astronomy, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2016-09-01

    This study utilises an electrohydrodynamic technique to prepare core-shell lipid nanoparticles with a tunable size and high active ingredient loading capacity, encapsulation efficiency and controlled release. Using stearic acid and ethylvanillin as model shell and active ingredients respectively, we identify the processing conditions and ratios of lipid:ethylvanillin required to form nanoparticles. Nanoparticles with a mean size ranging from 60 to 70 nm at the rate of 1.37 × 10{sup 9} nanoparticles per minute were prepared with different lipid:ethylvanillin ratios. The polydispersity index was ≈ 21% and the encapsulation efficiency ≈ 70%. It was found that the rate of ethylvanillin release was a function of the nanoparticle size, and lipid:ethylvanillin ratio. The internal structure of the lipid nanoparticles was studied by transmission electron microscopy which confirmed that the ethylvanillin was encapsulated within a stearic acid shell. Fourier transform infrared spectroscopy analysis indicated that the ethylvanillin had not been affected. Extensive analysis of the release of ethylvanillin was performed using several existing models and a new diffusive release model incorporating a tanh function. The results were consistent with a core-shell structure. - Highlights: • Electrohydrodynamic spraying is used to produce lipid-coated nanoparticles. • A new model is proposed for the release rates of active components from nanoparticles. • The technique has potential applications in food science and medicine. • Electrohydrodynamic processing controlled release lipid nanoparticles.

  15. Multi-component nuclear energy system to meet requirement of self-consistency

    International Nuclear Information System (INIS)

    Saito, Masaki; Artisyuk, Vladimir; Shmelev, Anotolii; Korovin, Yorii

    2000-01-01

    Environmental harmonization of nuclear energy technology is considered as an absolutely necessary condition in its future successful development for peaceful use. Establishment of Self-Consistent Nuclear Energy System, that simultaneously meets four requirements - energy production, fuel production, burning of radionuclides and safety, strongly relies on the neutron excess generation. Implementation of external non-fission based neutron sources into fission energy system would open the possibility of approaching Multicomponent Self-Consistent Nuclear Energy System with unlimited fuel resources, zero radioactivity release and high protection against uncontrolled proliferation of nuclear materials. (author)

  16. The consistency service of the ATLAS Distributed Data Management system

    CERN Document Server

    Serfon, C; The ATLAS collaboration

    2011-01-01

    With the continuously increasing volume of data produced by ATLAS and stored on the WLCG sites, the probability of data corruption or data losses, due to software and hardware failures is increasing. In order to ensure the consistency of all data produced by ATLAS a Consistency Service has been developed as part of the DQ2 Distributed Data Management system. This service is fed by the different ATLAS tools, i.e. the analysis tools, production tools, DQ2 site services or by site administrators that report corrupted or lost files. It automatically corrects the errors reported and informs the users in case of irrecoverable file loss.

  17. The Consistency Service of the ATLAS Distributed Data Management system

    CERN Document Server

    Serfon, C; The ATLAS collaboration

    2010-01-01

    With the continuously increasing volume of data produced by ATLAS and stored on the WLCG sites, the probability of data corruption or data losses, due to software and hardware failure is increasing. In order to ensure the consistency of all data produced by ATLAS a Consistency Service has been developed as part of the DQ2 Distributed Data Management system. This service is fed by the different ATLAS tools, i.e. the analysis tools, production tools, DQ2 site services or by site administrators that report corrupted or lost files. It automatically correct the errors reported and informs the users in case of irrecoverable file loss.

  18. Nicotine content of electronic cigarettes, its release in vapour and its consistency across batches: regulatory implications.

    Science.gov (United States)

    Goniewicz, Maciej L; Hajek, Peter; McRobbie, Hayden

    2014-03-01

    Electronic cigarettes (EC) may have a potential for public health benefit as a safer alternative to smoking, but questions have been raised about whether EC should be licensed as a medicine, with accurate labelling of nicotine content. This study determined the nicotine content of the cartridges of the most popular EC brands in the United Kingdom and the nicotine levels they deliver in the vapour, and estimated the safety and consistency of nicotine delivery across batches of the same product as a proxy for quality control for individual brands and within the industry. We studied five UK brands (six products) with high internet popularity. Two samples of each brand were purchased 4 weeks apart, and analysed for nicotine content in the cartridges and nicotine delivery in vapour. The nicotine content of cartridges within the same batch varied by up to 12% relative standard deviation (RSD) and the mean difference between different batches of the same brand ranged from 1% [95% confidence interval (CI) = -5 to 7%] to 20% (95% CI=14-25%) for five brands and 31% (95% CI=21-39%) for the sixth. The puffing schedule used in this study vaporized 10-81% of the nicotine present in the cartridges. The nicotine delivery from 300 puffs ranged from ∼2 mg to ∼15 mg and was not related significantly to the variation of nicotine content in e-liquid (r=0.06, P=0.92). None of the tested products allowed access to e-liquid or produced vapour nicotine concentrations as high as conventional cigarettes. There is very little risk of nicotine toxicity from major electronic cigarette (EC) brands in the United Kingdom. Variation in nicotine concentration in the vapour from a given brand is low. Nicotine concentration in e-liquid is not well related to nicotine in vapour. Other EC brands may be of lower quality and consumer protection regulation needs to be implemented, but in terms of accuracy of labelling of nicotine content and risks of nicotine overdose, regulation over and above

  19. Consistent approach to air-cleaning system duct design

    International Nuclear Information System (INIS)

    Miller, W.H.; Ornberg, S.C.; Rooney, K.L.

    1981-01-01

    Nuclear power plant air-cleaning system effectiveness is dependent on the capability of a duct system to safely convey contaminated gas to a filtration unit and subsequently to a point of discharge. This paper presents a logical and consistent design approach for selecting sheet metal ductwork construction to meet applicable criteria. The differences in design engineers' duct construction specifications are acknowledged. Typical duct construction details and suggestions for their effective use are presented. Improvements in duct design sections of ANSI/ASME N509-80 are highlighted. A detailed leakage analysis of a control room HVAC system is undertaken to illustrate the effects of conceptual design variations on duct construction requirements. Shortcomings of previously published analyses and interpretations of a current standard are included

  20. Thermodynamically consistent Bayesian analysis of closed biochemical reaction systems

    Directory of Open Access Journals (Sweden)

    Goutsias John

    2010-11-01

    Full Text Available Abstract Background Estimating the rate constants of a biochemical reaction system with known stoichiometry from noisy time series measurements of molecular concentrations is an important step for building predictive models of cellular function. Inference techniques currently available in the literature may produce rate constant values that defy necessary constraints imposed by the fundamental laws of thermodynamics. As a result, these techniques may lead to biochemical reaction systems whose concentration dynamics could not possibly occur in nature. Therefore, development of a thermodynamically consistent approach for estimating the rate constants of a biochemical reaction system is highly desirable. Results We introduce a Bayesian analysis approach for computing thermodynamically consistent estimates of the rate constants of a closed biochemical reaction system with known stoichiometry given experimental data. Our method employs an appropriately designed prior probability density function that effectively integrates fundamental biophysical and thermodynamic knowledge into the inference problem. Moreover, it takes into account experimental strategies for collecting informative observations of molecular concentrations through perturbations. The proposed method employs a maximization-expectation-maximization algorithm that provides thermodynamically feasible estimates of the rate constant values and computes appropriate measures of estimation accuracy. We demonstrate various aspects of the proposed method on synthetic data obtained by simulating a subset of a well-known model of the EGF/ERK signaling pathway, and examine its robustness under conditions that violate key assumptions. Software, coded in MATLAB®, which implements all Bayesian analysis techniques discussed in this paper, is available free of charge at http://www.cis.jhu.edu/~goutsias/CSS%20lab/software.html. Conclusions Our approach provides an attractive statistical methodology for

  1. Toward a consistent model for strain accrual and release for the New Madrid Seismic Zone, central United States

    Science.gov (United States)

    Hough, S.E.; Page, M.

    2011-01-01

    At the heart of the conundrum of seismogenesis in the New Madrid Seismic Zone is the apparently substantial discrepancy between low strain rate and high recent seismic moment release. In this study we revisit the magnitudes of the four principal 1811–1812 earthquakes using intensity values determined from individual assessments from four experts. Using these values and the grid search method of Bakun and Wentworth (1997), we estimate magnitudes around 7.0 for all four events, values that are significantly lower than previously published magnitude estimates based on macroseismic intensities. We further show that the strain rate predicted from postglacial rebound is sufficient to produce a sequence with the moment release of one Mmax6.8 every 500 years, a rate that is much lower than previous estimates of late Holocene moment release. However, Mw6.8 is at the low end of the uncertainty range inferred from analysis of intensities for the largest 1811–1812 event. We show that Mw6.8 is also a reasonable value for the largest main shock given a plausible rupture scenario. One can also construct a range of consistent models that permit a somewhat higher Mmax, with a longer average recurrence rate. It is thus possible to reconcile predicted strain and seismic moment release rates with alternative models: one in which 1811–1812 sequences occur every 500 years, with the largest events being Mmax∼6.8, or one in which sequences occur, on average, less frequently, with Mmax of ∼7.0. Both models predict that the late Holocene rate of activity will continue for the next few to 10 thousand years.

  2. Improving risk assessment by defining consistent and reliable system scenarios

    Directory of Open Access Journals (Sweden)

    B. Mazzorana

    2009-02-01

    Full Text Available During the entire procedure of risk assessment for hydrologic hazards, the selection of consistent and reliable scenarios, constructed in a strictly systematic way, is fundamental for the quality and reproducibility of the results. However, subjective assumptions on relevant impact variables such as sediment transport intensity on the system loading side and weak point response mechanisms repeatedly cause biases in the results, and consequently affect transparency and required quality standards. Furthermore, the system response of mitigation measures to extreme event loadings represents another key variable in hazard assessment, as well as the integral risk management including intervention planning. Formative Scenario Analysis, as a supplement to conventional risk assessment methods, is a technique to construct well-defined sets of assumptions to gain insight into a specific case and the potential system behaviour. By two case studies, carried out (1 to analyse sediment transport dynamics in a torrent section equipped with control measures, and (2 to identify hazards induced by woody debris transport at hydraulic weak points, the applicability of the Formative Scenario Analysis technique is presented. It is argued that during scenario planning in general and with respect to integral risk management in particular, Formative Scenario Analysis allows for the development of reliable and reproducible scenarios in order to design more specifically an application framework for the sustainable assessment of natural hazards impact. The overall aim is to optimise the hazard mapping and zoning procedure by methodologically integrating quantitative and qualitative knowledge.

  3. A self-consistent nuclear energy supply system

    International Nuclear Information System (INIS)

    Fujii-e, Y.; Morita, T.; Kawakami, H.; Arie, K.; Suzuki, M.; Iida, M.; Yamazaki, H.

    1992-01-01

    A self-consistent nuclear energy supply system (SCNESS) is investigated for a Fast Reactor. SCNESS is proposed as a future stable energy supplier with no harmful influence on humans or environment for the ultimate goal of nuclear energy development. SCNESS should be inherently safe, be able to breed fissionable material, and transmute long-lived radioactive nuclides (i.e., minor actinides and long-lived fission products). The relationship between these characteristics and the spatial assignment of excess neutrons (v-1) for each characteristic are analyzed. The analysis shows that excess neutrons play an intrinsic role in realizing SCNESS. The reactor concept of SCNESS is investigated by considering utilization of excess neutrons. Results show that a small-size axially double-layered annular core with metal fuel is a choice candidate for SCNESS. SCNESS is concluded feasible. (author). 4 refs., 9 figs

  4. Consistent Steering System using SCTP for Bluetooth Scatternet Sensor Network

    Science.gov (United States)

    Dhaya, R.; Sadasivam, V.; Kanthavel, R.

    2012-12-01

    Wireless communication is the best way to convey information from source to destination with flexibility and mobility and Bluetooth is the wireless technology suitable for short distance. On the other hand a wireless sensor network (WSN) consists of spatially distributed autonomous sensors to cooperatively monitor physical or environmental conditions, such as temperature, sound, vibration, pressure, motion or pollutants. Using Bluetooth piconet wireless technique in sensor nodes creates limitation in network depth and placement. The introduction of Scatternet solves the network restrictions with lack of reliability in data transmission. When the depth of the network increases, it results in more difficulties in routing. No authors so far focused on the reliability factors of Scatternet sensor network's routing. This paper illustrates the proposed system architecture and routing mechanism to increase the reliability. The another objective is to use reliable transport protocol that uses the multi-homing concept and supports multiple streams to prevent head-of-line blocking. The results show that the Scatternet sensor network has lower packet loss even in the congestive environment than the existing system suitable for all surveillance applications.

  5. Consistency conditions for data base systems: a new problem of systems analysis

    International Nuclear Information System (INIS)

    Schlageter, G.

    1976-01-01

    A data base can be seen as a model of a system in the real world. During the systems analysis conditions must be derived which guarantee a close correspondence between the real system and the data base. These conditions are called consistency constraints. The notion of consistency is analyzed; different types of consistency constraints are presented. (orig.) [de

  6. Student Consistency and Implications for Feedback in Online Assessment Systems

    Science.gov (United States)

    Madhyastha, Tara M.; Tanimoto, Steven

    2009-01-01

    Most of the emphasis on mining online assessment logs has been to identify content-specific errors. However, the pattern of general "consistency" is domain independent, strongly related to performance, and can itself be a target of educational data mining. We demonstrate that simple consistency indicators are related to student outcomes,…

  7. Understanding and Improving the Performance Consistency of Distributed Computing Systems

    NARCIS (Netherlands)

    Yigitbasi, M.N.

    2012-01-01

    With the increasing adoption of distributed systems in both academia and industry, and with the increasing computational and storage requirements of distributed applications, users inevitably demand more from these systems. Moreover, users also depend on these systems for latency and throughput

  8. An Evaluation of Information Consistency in Grid Information Systems

    CERN Document Server

    Field, Laurence

    2017-01-01

    A Grid information system resolves queries that may need to consider all information sources (Grid services), which are widely distributed geographically, in order to enable efficient Grid functions that may utilise multiple cooperating services. Fundamentally this can be achieved by either moving the query to the data (query shipping) or moving the data to the query (data shipping). Existing Grid information system implementations have adopted one of the two approaches. This paper explores the two approaches in further detail by evaluating them to the best possible extent with respect to Grid information system benchmarking metrics. A Grid information system that follows the data shipping approach based on the replication of information that aims to improve the currency for highly-mutable information is presented. An implementation of this, based on an Enterprise Messaging System, is evaluated using the benchmarking method and the consequence of the results for the design of Grid information systems is discu...

  9. Promoting consistent use of the communication function classification system (CFCS).

    Science.gov (United States)

    Cunningham, Barbara Jane; Rosenbaum, Peter; Hidecker, Mary Jo Cooley

    2016-01-01

    We developed a Knowledge Translation (KT) intervention to standardize the way speech-language pathologists working in Ontario Canada's Preschool Speech and Language Program (PSLP) used the Communication Function Classification System (CFCS). This tool was being used as part of a provincial program evaluation and standardizing its use was critical for establishing reliability and validity within the provincial dataset. Two theoretical foundations - Diffusion of Innovations and the Communication Persuasion Matrix - were used to develop and disseminate the intervention to standardize use of the CFCS among a cohort speech-language pathologists. A descriptive pre-test/post-test study was used to evaluate the intervention. Fifty-two participants completed an electronic pre-test survey, reviewed intervention materials online, and then immediately completed an electronic post-test survey. The intervention improved clinicians' understanding of how the CFCS should be used, their intentions to use the tool in the standardized way, and their abilities to make correct classifications using the tool. Findings from this work will be shared with representatives of the Ontario PSLP. The intervention may be disseminated to all speech-language pathologists working in the program. This study can be used as a model for developing and disseminating KT interventions for clinicians in paediatric rehabilitation. The Communication Function Classification System (CFCS) is a new tool that allows speech-language pathologists to classify children's skills into five meaningful levels of function. There is uncertainty and inconsistent practice in the field about the methods for using this tool. This study used combined two theoretical frameworks to develop an intervention to standardize use of the CFCS among a cohort of speech-language pathologists. The intervention effectively increased clinicians' understanding of the methods for using the CFCS, ability to make correct classifications, and

  10. Flavor release measurement from gum model system.

    Science.gov (United States)

    Ovejero-López, Isabel; Haahr, Anne-Mette; van den Berg, Frans; Bredie, Wender L P

    2004-12-29

    Flavor release from a mint-flavored chewing gum model system was measured by atmospheric pressure chemical ionization mass spectroscopy (APCI-MS) and sensory time-intensity (TI). A data analysis method for handling the individual curves from both methods is presented. The APCI-MS data are ratio-scaled using the signal from acetone in the breath of subjects. Next, APCI-MS and sensory TI curves are smoothed by low-pass filtering. Principal component analysis of the individual curves is used to display graphically the product differentiation by APCI-MS or TI signals. It is shown that differences in gum composition can be measured by both instrumental and sensory techniques, providing comparable information. The peppermint oil level (0.5-2% w/w) in the gum influenced both the retronasal concentration and the perceived peppermint flavor. The sweeteners' (sorbitol or xylitol) effect is less apparent. Sensory adaptation and sensitivity differences of human perception versus APCI-MS detection might explain the divergence between the two dynamic measurement methods.

  11. Overview study of LNG release prevention and control systems

    Energy Technology Data Exchange (ETDEWEB)

    Pelto, P.J.; Baker, E.G.; Holter, G.M.; Powers, T.B.

    1982-03-01

    The liquefied natural gas (LNG) industry employs a variety of release prevention and control techniques to reduce the likelihood and the consequences of accidental LNG releases. A study of the effectiveness of these release prevention and control systems is being performed. Reference descriptions for the basic types of LNG facilities were developed. Then an overview study was performed to identify areas that merit subsequent and more detailed analyses. The specific objectives were to characterize the LNG facilities of interest and their release prevention and control systems, identify possible weak links and research needs, and provide an analytical framework for subsequent detailed analyses. The LNG facilities analyzed include a reference export terminal, marine vessel, import terminal, peakshaving facility, truck tanker, and satellite facility. A reference description for these facilities, a preliminary hazards analysis (PHA), and a list of representative release scenarios are included. The reference facility descriptions outline basic process flows, plant layouts, and safety features. The PHA identifies the important release prevention operations. Representative release scenarios provide a format for discussing potential initiating events, effects of the release prevention and control systems, information needs, and potential design changes. These scenarios range from relatively frequent but low consequence releases to unlikely but large releases and are the principal basis for the next stage of analysis.

  12. Dual-controlled release system of drugs for bone regeneration.

    Science.gov (United States)

    Kim, Yang-Hee; Tabata, Yasuhiko

    2015-11-01

    Controlled release systems have been noted to allow drugs to enhance their ability for bone regeneration. To this end, various biomaterials have been used as the release carriers of drugs, such as low-molecular-weight drugs, growth factors, and others. The drugs are released from the release carriers in a controlled fashion to maintain their actions for a long time period. Most research has been focused on the controlled release of single drugs to demonstrate the therapeutic feasibility. Controlled release of two combined drugs, so-called dual release systems, are promising and important for tissue regeneration. This is because the tissue regeneration process of bone formation is generally achieved by multiple bioactive molecules, which are produced from cells by other molecules. If two types of bioactive molecules, (i.e., drugs), are supplied in an appropriate fashion, the regeneration process of living bodies will be efficiently promoted. This review focuses on the bone regeneration induced by dual-controlled release of drugs. In this paper, various dual-controlled release systems of drugs aiming at bone regeneration are overviewed explaining the type of drugs and their release materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Introduction to CRRIS: a computerized radiological risk investigation system for assessing atmospheric releases of radionuclides

    International Nuclear Information System (INIS)

    Baes, C.F. III; Miller, C.W.; Kocher, D.C.; Sjoreen, A.L.; Murphy, B.D.

    1985-08-01

    The CRRIS is a Computerized Radiological Risk Investigation System consisting of eight fully integrated computer codes which calculate environmental transport of atmospheric releases of radionuclides and resulting doses and health risks to individuals or populations. Each code may also be used alone for various assessment applications. Radionuclides are handled by the CRRIS either in terms of the released radionuclides or the exposure radionuclides which consist of both the released nuclides and decay products that grow in during environmental transport. The CRRIS is not designed to simulate short-term effects. 51 refs

  14. FACTORS AFFECTING THE RELEASE RATE OF A HIGHLY SOLUBLE DRUG FROM A PROGRAMMED RELEASE MEGALOPOROUS SYSTEM

    NARCIS (Netherlands)

    VANDERVEEN, C; MENGER, NR; LERK, CF

    The present study reports on the successful incorporation of a highly soluble drug, procaine HCl, in a programmed-release megaloporous system. This solid two-phase system is composed of housing phase matrix granules (HMG), controlling liquid penetration into the system, and of restraining phase

  15. The role of interactive control systems in obtaining internal consistency in the management control system package

    DEFF Research Database (Denmark)

    Toldbod, Thomas; Israelsen, Poul

    2014-01-01

    Companies rely on multiple Management Control Systems to obtain their short and long term objectives. When applying a multifaceted perspective on Management Control System the concept of internal consistency has been found to be important in obtaining goal congruency in the company. However, to d...... management is aware of this shortcoming they use the cybernetic controls more interactively to overcome this shortcoming, whereby the cybernetic controls are also used as a learning platform and not just for performance control....

  16. Controlled release system for ametryn using polymer microspheres: Preparation, characterization and release kinetics in water

    International Nuclear Information System (INIS)

    Grillo, Renato; Pereira, Anderson do Espirito Santo; Ferreira Silva de Melo, Nathalie; Porto, Raquel Martins; Feitosa, Leandro Oliveira; Tonello, Paulo Sergio; Dias Filho, Newton L.; Rosa, Andre Henrique; Lima, Renata; Fraceto, Leonardo Fernandes

    2011-01-01

    The purpose of this work was to develop a modified release system for the herbicide ametryn by encapsulating the active substance in biodegradable polymer microparticles produced using the polymers poly(hydroxybutyrate) (PHB) or poly(hydroxybutyrate-valerate) (PHBV), in order to both improve the herbicidal action and reduce environmental toxicity. PHB or PHBV microparticles containing ametryn were prepared and the efficiencies of herbicide association and loading were evaluated, presenting similar values of approximately 40%. The microparticles were characterized by scanning electron microscopy (SEM), which showed that the average sizes of the PHB and PHBV microparticles were 5.92 ± 0.74 μm and 5.63 ± 0.68 μm, respectively. The ametryn release profile was modified when it was encapsulated in the microparticles, with slower and more sustained release compared to the release profile of pure ametryn. When ametryn was associated with the PHB and PHBV microparticles, the amount of herbicide released in the same period of time was significantly reduced, declining to 75% and 87%, respectively. For both types of microparticle (PHB and PHBV) the release of ametryn was by diffusion processes due to anomalous transport (governed by diffusion and relaxation of the polymer chains), which did not follow Fick's laws of diffusion. The results presented in this paper are promising, in view of the successful encapsulation of ametryn in PHB or PHBV polymer microparticles, and indications that this system may help reduce the impacts caused by the herbicide, making it an environmentally safer alternative.

  17. Defined drug release from 3D-printed composite tablets consisting of drug-loaded polyvinylalcohol and a water-soluble or water-insoluble polymer filler.

    Science.gov (United States)

    Tagami, Tatsuaki; Nagata, Noriko; Hayashi, Naomi; Ogawa, Emi; Fukushige, Kaori; Sakai, Norihito; Ozeki, Tetsuya

    2018-05-30

    3D-printed tablets are a promising new approach for personalized medicine. In this study, we fabricated composite tablets consisting of two components, a drug and a filler, by using a fused deposition modeling-type 3D printer. Polyvinylalcohol (PVA) polymer containing calcein (a model drug) was used as the drug component and PVA or polylactic acid (PLA) polymer without drug was used as the water-soluble or water-insoluble filler, respectively. Various kinds of drug-PVA/PVA and drug-PVA/PLA composite tablets were designed, and the 3D-printed tablets exhibited good formability. The surface area of the exposed drug component is highly correlated with the initial drug release rate. Composite tablets with an exposed top and a bottom covered with a PLA layer were fabricated. These tablets showed zero-order drug release by maintaining the surface area of the exposed drug component during drug dissolution. In contrast, the drug release profile varied for tablets whose exposed surface area changed. Composite tablets with different drug release lag times were prepared by changing the thickness of the PVA filler coating the drug component. These results which used PVA and PLA filler will provide useful information for preparing the tablets with multi-components and tailor-made tablets with defined drug release profiles using 3D printers. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Nutrient Release from Disturbance of Infiltration System Soils during Construction

    OpenAIRE

    Daniel P. Treese; Shirley E. Clark; Katherine H. Baker

    2012-01-01

    Subsurface infiltration and surface bioretention systems composed of engineered and/or native soils are preferred tools for stormwater management. However, the disturbance of native soils, especially during the process of adding amendments to improve infiltration rates and pollutant removal, may result in releases of nutrients in the early life of these systems. This project investigated the nutrient release from two soils, one disturbed and one undisturbed. The disturbed soil was collected i...

  19. Monoterpenes released from fruit, plant, and vegetable systems.

    Science.gov (United States)

    Iqbal, Mohammad Asif; Kim, Ki-Hyun; Ahn, Jeong Hyeon

    2014-09-29

    To quantify the emission rate of monoterpenes (MTs) from diverse natural sources, the sorbent tube (ST)-thermal desorption (TD) method was employed to conduct the collection and subsequent detection of MTs by gas chromatography. The calibration of MTs, when made by both mass spectrometric (MS) and flame ionization detector (FID), consistently exhibited high coefficient of determination values (R2 > 0.99). This approach was employed to measure their emission rate from different fruit/plant/vegetable (F/P/V) samples with the aid of an impinger-based dynamic headspace sampling system. The results obtained from 10 samples (consisting of carrot, pine needle (P. sylvestris), tangerine, tangerine peel, strawberry, sepals of strawberry, plum, apple, apple peel, and orange juice) marked α-pinene, β-pinene, myrcene, α-terpinene, R-limonene, γ-terpinene, and p-cymene as the most common MTs. R-limonene was the major species emitted from citrus fruits and beverages with its abundance exceeding 90%. In contrast, α-pinene was the most abundant MT (37%) for carrot, while it was myrcene (31%) for pine needle. The overall results for F/P/V samples confirmed α-pinene, β-pinene, myrcene, α-terpinene, and γ-terpinene as common MTs. Nonetheless, the types and magnitude of MTs released from fruits were distinguished from those of vegetables and plants.

  20. Monoterpenes Released from Fruit, Plant, and Vegetable Systems

    Directory of Open Access Journals (Sweden)

    Mohammad Asif Iqbal

    2014-09-01

    Full Text Available To quantify the emission rate of monoterpenes (MTs from diverse natural sources, the sorbent tube (ST-thermal desorption (TD method was employed to conduct the collection and subsequent detection of MTs by gas chromatography. The calibration of MTs, when made by both mass spectrometric (MS and flame ionization detector (FID, consistently exhibited high coefficient of determination values (R2 > 0.99. This approach was employed to measure their emission rate from different fruit/plant/vegetable (F/P/V samples with the aid of an impinger-based dynamic headspace sampling system. The results obtained from 10 samples (consisting of carrot, pine needle (P. sylvestris, tangerine, tangerine peel, strawberry, sepals of strawberry, plum, apple, apple peel, and orange juice marked α-pinene, β-pinene, myrcene, α-terpinene, R-limonene, γ-terpinene, and p-cymene as the most common MTs. R-limonene was the major species emitted from citrus fruits and beverages with its abundance exceeding 90%. In contrast, α-pinene was the most abundant MT (37% for carrot, while it was myrcene (31% for pine needle. The overall results for F/P/V samples confirmed α-pinene, β-pinene, myrcene, α-terpinene, and γ-terpinene as common MTs. Nonetheless, the types and magnitude of MTs released from fruits were distinguished from those of vegetables and plants.

  1. Release mitigation spray safety systems for chemical demilitarization applications.

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Jonathan; Tezak, Matthew Stephen; Brockmann, John E.; Servantes, Brandon; Sanchez, Andres L.; Tucker, Mark David; Allen, Ashley N.; Wilson, Mollye C.; Lucero, Daniel A.; Betty, Rita G.

    2010-06-01

    Sandia National Laboratories has conducted proof-of-concept experiments demonstrating effective knockdown and neutralization of aerosolized CBW simulants using charged DF-200 decontaminant sprays. DF-200 is an aqueous decontaminant, developed by Sandia National Laboratories, and procured and fielded by the US Military. Of significance is the potential application of this fundamental technology to numerous applications including mitigation and neutralization of releases arising during chemical demilitarization operations. A release mitigation spray safety system will remove airborne contaminants from an accidental release during operations, to protect personnel and limit contamination. Sandia National Laboratories recently (November, 2008) secured funding from the US Army's Program Manager for Non-Stockpile Chemical Materials Agency (PMNSCMA) to investigate use of mitigation spray systems for chemical demilitarization applications. For non-stockpile processes, mitigation spray systems co-located with the current Explosive Destruction System (EDS) will provide security both as an operational protective measure and in the event of an accidental release. Additionally, 'tented' mitigation spray systems for native or foreign remediation and recovery operations will contain accidental releases arising from removal of underground, unstable CBW munitions. A mitigation spray system for highly controlled stockpile operations will provide defense from accidental spills or leaks during routine procedures.

  2. Microelectromechanical high-density energy storage/rapid release system

    Science.gov (United States)

    Rodgers, M. Steven; Allen, James J.; Meeks, Kent D.; Jensen, Brian D.; Miller, Samuel L.

    1999-08-01

    One highly desirable characteristic of electrostatically driven microelectromechanical systems (MEMS) is that they consume very little power. The corresponding drawback is that the force they produce may be inadequate for many applications. It has previously been demonstrated that gear reduction units or microtransmissions can substantially increase the torque generated by microengines. Operating speed, however, is also reduced by the transmission gear ratio. Some applications require both high speed and high force. If this output is only required for a limited period of time, then energy could be stored in a mechanical system and rapidly released upon demand. We have designed, fabricated, and demonstrated a high-density energy storage/rapid release system that accomplishes this task. Built using a 5-level surface micromachining technology, the assembly closely resembles a medieval crossbow. Energy releases on the order of tens of nanojoules have already been demonstrated, and significantly higher energy systems are under development.

  3. Optimal integration and test plans for software releases of lithographic systems

    NARCIS (Netherlands)

    Boumen, R.; Jong, de I.S.M.; Mortel - Fronczak, van de J.M.; Rooda, J.E.

    2007-01-01

    This paper describes a method to determine the optimal integration and test plan for embedded systems software releases. The method consists of four steps: 1)describe the integration and test problem in an integration and test model which is introduced in this paper, 2) determine possible test

  4. A multifunctional multimaterial system for on-demand protein release.

    Science.gov (United States)

    Tuncaboylu, Deniz Ceylan; Friess, Fabian; Wischke, Christian; Lendlein, Andreas

    2018-06-15

    In order to provide best control of the regeneration process for each individual patient, the release of protein drugs administered during surgery may need to be timely adapted and/or delayed according to the progress of healing/regeneration. This study aims to establish a multifunctional implant system for a local on-demand release, which is applicable for various types of proteins. It was hypothesized that a tubular multimaterial container kit, which hosts the protein of interest as a solution or gel formulation, would enable on-demand release if equipped with the capacity of diameter reduction upon external stimulation. Using devices from poly(ɛ-caprolactone) networks, it could be demonstrated that a shape-memory effect activated by heat or NIR light enabled on-demand tube shrinkage. The decrease of diameter of these shape-memory tubes (SMT) allowed expelling the payload as demonstrated for several proteins including SDF-1α, a therapeutically relevant chemotactic protein, to achieve e.g. continuous release with a triggered add-on dosing (open tube) or an on-demand onset of bolus or sustained release (sealed tube). Considering the clinical relevance of protein factors in (stem) cell attraction to lesions and the progress in monitoring biomarkers in body fluids, such on-demand release systems may be further explored e.g. in heart, nerve, or bone regeneration in the future. Copyright © 2018. Published by Elsevier B.V.

  5. Release Early, Release Often: Predicting Change in Versioned Knowledge Organization Systems on the Web

    OpenAIRE

    Meroño-Peñuela, Albert; Guéret, Christophe; Schlobach, Stefan

    2015-01-01

    The Semantic Web is built on top of Knowledge Organization Systems (KOS) (vocabularies, ontologies, concept schemes) that provide a structured, interoperable and distributed access to Linked Data on the Web. The maintenance of these KOS over time has produced a number of KOS version chains: subsequent unique version identifiers to unique states of a KOS. However, the release of new KOS versions pose challenges to both KOS publishers and users. For publishers, updating a KOS is a knowledge int...

  6. Solution of degenerate hypergeometric system of Horn consisting of three equations

    Science.gov (United States)

    Tasmambetov, Zhaksylyk N.; Zhakhina, Ryskul U.

    2017-09-01

    The possibilities of constructing normal-regular solutions of a system consisting of three partial differential equations of the second order are studied by the Frobenius-Latysheva method. The method of determining unknown coefficients is shown and the relationship of the studied system with the system, which solution is Laguerre's polynomial of three variables is indicated. The generalization of the Frobenius-Latysheva method to the case of a system consisting of three equations makes it possible to clarify the relationship of such systems, which solutions are special functions of three variables. These systems include the functions of Whittaker and Bessel, 205 special functions of three variables from the list of M. Srivastava and P.W. Carlsson, as well as orthogonal polynomials of three variables. All this contributes to the further development of the analytic theory of systems consisting of three partial differential equations of the second order.

  7. The Atmospheric Release Advisory Capability Site Workstation System

    International Nuclear Information System (INIS)

    Foster, K.T.; Sumikawa, D.A.; Foster, C.S.; Baskett, R.L.

    1993-01-01

    The Atmospheric Release Advisory Capability (ARAC) is a centralized emergency response service that assesses the consequences that may result from an atmospheric release of toxic material. ARAC was developed by the Lawrence Livermore National Laboratory (LLNL) for the Departments of Energy (DOE) and Defense (DOD) and responds principally to radiological accidents. ARAC provides radiological health and safety guidance to decision makers in the form of computer-generated estimates of the effects of an actual, or potential release of radioactive material into the atmosphere. Upon receipt of the release scenario, the ARAC assessment staff extracts meteorological, topographic, and geographic data from resident world-wide databases for use in complex, three-dimensional transport and diffusion models. These dispersion models generate air concentration (or dose) and ground deposition contour plots showing estimates of the contamination patterns produced as the toxic material is carried by the prevailing winds. To facilitate the ARAC response to a release from specific DOE and DOD sites and to provide these sites with a local emergency response tool, a remote Site Workstation System (SWS) is being placed at various ARAC-supported facilities across the country.. This SWS replaces the existing antiquated ARAC Site System now installed at many of these sites. The new system gives users access to complex atmospheric dispersion models that may be run either by the ARAC staff at LLNL, or (in a later phase of the system) by site personnel using the computational resources of the SWS. Supporting this primary function are a variety of SWS-resident supplemental capabilities that include meteorological data acquisition, manipulation of release-specific databases, computer-based communications, and the use of a simpler Gaussian trajectory puff model that is based on Environmental Protection Agency's INPUFF code

  8. Nutrient Release from Disturbance of Infiltration System Soils during Construction

    Directory of Open Access Journals (Sweden)

    Daniel P. Treese

    2012-01-01

    Full Text Available Subsurface infiltration and surface bioretention systems composed of engineered and/or native soils are preferred tools for stormwater management. However, the disturbance of native soils, especially during the process of adding amendments to improve infiltration rates and pollutant removal, may result in releases of nutrients in the early life of these systems. This project investigated the nutrient release from two soils, one disturbed and one undisturbed. The disturbed soil was collected intact, but had to be air-dried, and the columns repacked when soil shrinkage caused bypassing of water along the walls of the column. The undisturbed soil was collected and used intact, with no repacking. The disturbed soil showed elevated releases of nitrogen and phosphorus compared to the undisturbed soil for approximately 0.4 and 0.8 m of runoff loading, respectively. For the undisturbed soil, the nitrogen release was delayed, indicating that the soil disturbance accelerated the release of nitrogen into a very short time period. Leaving the soil undisturbed resulted in lower but still elevated effluent nitrogen concentrations over a longer period of time. For phosphorus, these results confirm prior research which demonstrated that the soil, if shown to be phosphorus-deficient during fertility testing, can remove phosphorus from runoff even when disturbed.

  9. Consistency of direct integral estimator for partially observed systems of ordinary differential equations

    NARCIS (Netherlands)

    Vujačić, Ivan; Dattner, Itai

    In this paper we use the sieve framework to prove consistency of the ‘direct integral estimator’ of parameters for partially observed systems of ordinary differential equations, which are commonly used for modeling dynamic processes.

  10. Generation of static solutions of the self-consistent system of Einstein-Maxwell equations

    International Nuclear Information System (INIS)

    Anchikov, A.M.; Daishev, R.A.

    1988-01-01

    A theorem is proved, according to which to each solution of the Einstein equations with an arbitrary momentum-energy tensor in the right hand side there corresponds a static solution of the self-consistent system of Einstein-Maxwell equations. As a consequence of this theorem, a method is established of generating static solutions of the self-consistent system of Einstein-Maxwell equations with a charged grain as a source of vacuum solutions of the Einstein equations

  11. A novel fluoride anion modified gelatin nanogel system for ultrasound-triggered drug release.

    Science.gov (United States)

    Wu, Daocheng; Wan, Mingxi

    2008-01-01

    Controlled drug release, especially tumor-targeted drug release, remains a great challenge. Here, we prepare a novel fluoride anion-modified gelatin nanogel system and investigate its characteristics of ultrasound-triggered drug release. Adriamycin gelatin nanogel modified with fluoride anion (ADM-GNMF) was prepared by a modified co-precipitation method with fluoride anion and sodium sulfate. The loading and encapsulation efficiency of the anti-neoplastic agent adriamycin (ADM) were measured by high performance liquid chromatography (HPLC). The size and shape of ADM-GNMF were determined by electron microscopy and photo-correlation spectroscopy. The size distribution and drug release efficiency of ADM-GNMF, before and after sonication, were measured by two designed measuring devices that consisted of either a submicron particle size analyzer and an ultrasound generator as well as an ultrasound generator, automatic sampler, and HPLC. The ADM-GNMF was stable in solution with an average diameter of 46+/-12 nm; the encapsulation and loading efficiency of adriamycin were 87.2% and 6.38%, respectively. The ultrasound-triggered drug release and size change were most efficient at a frequency of 20 kHz, power density of 0.4w/cm2, and a 1~2 min duration. Under this ultrasound-triggered condition, 51.5% of drug in ADM-GNMF was released within 1~2 min, while the size of ADM-GNMF changed from 46 +/- 12 nm to 1212 +/- 35 nm within 1~2 min of sonication and restored to its previous size in 2~3 min after the ultrasound stopped. In contrast, 8.2% of drug in ADM-GNMF was released within 2~3 min without sonication, and only negligible size changes were found. The ADM-GNMF system efficiently released the encompassed drug in response to ultrasound, offering a novel and promising controlled drug release system for targeted therapy for cancer or other diseases.

  12. Formal modelling and verification of interlocking systems featuring sequential release

    DEFF Research Database (Denmark)

    Vu, Linh Hong; Haxthausen, Anne Elisabeth; Peleska, Jan

    2017-01-01

    In this article, we present a method and an associated toolchain for the formal verification of the new Danish railway interlocking systems that are compatible with the European Train Control System (ETCS) Level 2. We have made a generic and reconfigurable model of the system behaviour and generic...... safety properties. This model accommodates sequential release - a feature in the new Danish interlocking systems. To verify the safety of an interlocking system, first a domain-specific description of interlocking configuration data is constructed and validated. Then the generic model and safety...

  13. Multicompartment Drug Release System for Dynamic Modulation of Tissue Responses.

    Science.gov (United States)

    Morris, Aaron H; Mahal, Rajwant S; Udell, Jillian; Wu, Michelle; Kyriakides, Themis R

    2017-10-01

    Pharmacological modulation of responses to injury is complicated by the need to deliver multiple drugs with spatiotemporal resolution. Here, a novel controlled delivery system containing three separate compartments with each releasing its contents over different timescales is fabricated. Core-shell electrospun fibers create two of the compartments in the system, while electrosprayed spheres create the third. Utility is demonstrated by targeting the foreign body response to implants because it is a dynamic process resulting in implant failure. Sequential delivery of a drug targeting nuclear factor-κB (NF-κB) and an antifibrotic is characterized in in vitro experiments. Specifically, macrophage fusion and p65 nuclear translocation in the presence of releasate or with macrophages cultured on the surfaces of the constructs are evaluated. In addition, releasate from pirfenidone scaffolds is shown to reduce transforming growth factor-β (TGF-β)-induced pSMAD3 nuclear localization in fibroblasts. In vivo, drug eluting constructs successfully mitigate macrophage fusion at one week and fibrotic encapsulation in a dose-dependent manner at four weeks, demonstrating effective release of both drugs over different timescales. Future studies can employ this system to improve and prolong implant lifetimes, or load it with other drugs to modulate other dynamic processes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Injectable In-Situ Gelling Controlled Release Drug Delivery System

    OpenAIRE

    Kulwant Singh; S. L. HariKumar

    2012-01-01

    The administration of poorly bioavailable drug through parenteral route is regarded the most efficient for drug delivery. Parenteral delivery provides rapid onset even for the drug with narrow therapeutic window, but to maintain the systemic drug level repeated installation are required which cause the patient discomfort. This can be overcome by designing the drug into a system, which control the drug release even through parenteral delivery, which improve patient compliance as well as pharma...

  15. Method used to test the imaging consistency of binocular camera's left-right optical system

    Science.gov (United States)

    Liu, Meiying; Wang, Hu; Liu, Jie; Xue, Yaoke; Yang, Shaodong; Zhao, Hui

    2016-09-01

    To binocular camera, the consistency of optical parameters of the left and the right optical system is an important factor that will influence the overall imaging consistency. In conventional testing procedure of optical system, there lacks specifications suitable for evaluating imaging consistency. In this paper, considering the special requirements of binocular optical imaging system, a method used to measure the imaging consistency of binocular camera is presented. Based on this method, a measurement system which is composed of an integrating sphere, a rotary table and a CMOS camera has been established. First, let the left and the right optical system capture images in normal exposure time under the same condition. Second, a contour image is obtained based on the multiple threshold segmentation result and the boundary is determined using the slope of contour lines near the pseudo-contour line. Third, the constraint of gray level based on the corresponding coordinates of left-right images is established and the imaging consistency could be evaluated through standard deviation σ of the imaging grayscale difference D (x, y) between the left and right optical system. The experiments demonstrate that the method is suitable for carrying out the imaging consistency testing for binocular camera. When the standard deviation 3σ distribution of imaging gray difference D (x, y) between the left and right optical system of the binocular camera does not exceed 5%, it is believed that the design requirements have been achieved. This method could be used effectively and paves the way for the imaging consistency testing of the binocular camera.

  16. Consistency properties of chaotic systems driven by time-delayed feedback

    Science.gov (United States)

    Jüngling, T.; Soriano, M. C.; Oliver, N.; Porte, X.; Fischer, I.

    2018-04-01

    Consistency refers to the property of an externally driven dynamical system to respond in similar ways to similar inputs. In a delay system, the delayed feedback can be considered as an external drive to the undelayed subsystem. We analyze the degree of consistency in a generic chaotic system with delayed feedback by means of the auxiliary system approach. In this scheme an identical copy of the nonlinear node is driven by exactly the same signal as the original, allowing us to verify complete consistency via complete synchronization. In the past, the phenomenon of synchronization in delay-coupled chaotic systems has been widely studied using correlation functions. Here, we analytically derive relationships between characteristic signatures of the correlation functions in such systems and unequivocally relate them to the degree of consistency. The analytical framework is illustrated and supported by numerical calculations of the logistic map with delayed feedback for different replica configurations. We further apply the formalism to time series from an experiment based on a semiconductor laser with a double fiber-optical feedback loop. The experiment constitutes a high-quality replica scheme for studying consistency of the delay-driven laser and confirms the general theoretical results.

  17. The Development of Australia's National Training System: A Dynamic Tension between Consistency and Flexibility. Occasional Paper

    Science.gov (United States)

    Bowman, Kaye; McKenna, Suzy

    2016-01-01

    This occasional paper provides an overview of the development of Australia's national training system and is a key knowledge document of a wider research project "Consistency with flexibility in the Australian national training system." This research project investigates the various approaches undertaken by each of the jurisdictions to…

  18. A consistent description of kinetics and hydrodynamics of quantum Bose-systems

    Directory of Open Access Journals (Sweden)

    P.A.Hlushak

    2004-01-01

    Full Text Available A consistent approach to the description of kinetics and hydrodynamics of many-Boson systems is proposed. The generalized transport equations for strongly and weakly nonequilibrium Bose systems are obtained. Here we use the method of nonequilibrium statistical operator by D.N. Zubarev. New equations for the time distribution function of the quantum Bose system with a separate contribution from both the kinetic and potential energies of particle interactions are obtained. The generalized transport coefficients are determined accounting for the consistent description of kinetic and hydrodynamic processes.

  19. Controlled release systems containing solid dispersions: strategies and mechanisms.

    Science.gov (United States)

    Tran, Phuong Ha-Lien; Tran, Thao Truong-Dinh; Park, Jun Bom; Lee, Beom-Jin

    2011-10-01

    In addition to a number of highly soluble drugs, most new chemical entities under development are poorly water-soluble drugs generally characterized by an insufficient dissolution rate and a small absorption window, leading to the low bioavailability. Controlled-release (CR) formulations have several potential advantages over conventional dosage forms, such as providing a uniform and prolonged therapeutic effect to improve patient compliance, reducing the frequency of dosing, minimizing the number of side effects, and reducing the strength of the required dose while increasing the effectiveness of the drug. Solid dispersions (SD) can be used to enhance the dissolution rate of poorly water-soluble drugs and to sustain the drug release by choosing an appropriate carrier. Thus, a CR-SD comprises both functions of SD and CR for poorly water-soluble drugs. Such CR dosage forms containing SD provide an immediately available dose for an immediate action followed by a gradual and continuous release of subsequent doses to maintain the plasma concentration of poorly water-soluble drugs over an extended period of time. This review aims to summarize all currently known aspects of controlled release systems containing solid dispersions, focusing on the preparation methods, mechanisms of action and characterization of physicochemical properties of the system.

  20. A proposed grading system for standardizing tumor consistency of intracranial meningiomas.

    Science.gov (United States)

    Zada, Gabriel; Yashar, Parham; Robison, Aaron; Winer, Jesse; Khalessi, Alexander; Mack, William J; Giannotta, Steven L

    2013-12-01

    Tumor consistency plays an important and underrecognized role in the surgeon's ability to resect meningiomas, especially with evolving trends toward minimally invasive and keyhole surgical approaches. Aside from descriptors such as "hard" or "soft," no objective criteria exist for grading, studying, and conveying the consistency of meningiomas. The authors designed a practical 5-point scale for intraoperative grading of meningiomas based on the surgeon's ability to internally debulk the tumor and on the subsequent resistance to folding of the tumor capsule. Tumor consistency grades and features are as follows: 1) extremely soft tumor, internal debulking with suction only; 2) soft tumor, internal debulking mostly with suction, and remaining fibrous strands resected with easily folded capsule; 3) average consistency, tumor cannot be freely suctioned and requires mechanical debulking, and the capsule then folds with relative ease; 4) firm tumor, high degree of mechanical debulking required, and capsule remains difficult to fold; and 5) extremely firm, calcified tumor, approaches density of bone, and capsule does not fold. Additional grading categories included tumor heterogeneity (with minimum and maximum consistency scores) and a 3-point vascularity score. This grading system was prospectively assessed in 50 consecutive patients undergoing craniotomy for meningioma resection by 2 surgeons in an independent fashion. Grading scores were subjected to a linear weighted kappa analysis for interuser reliability. Fifty patients (100 scores) were included in the analysis. The mean maximal tumor diameter was 4.3 cm. The distribution of overall tumor consistency scores was as follows: Grade 1, 4%; Grade 2, 9%; Grade 3, 43%; Grade 4, 44%; and Grade 5, 0%. Regions of Grade 5 consistency were reported only focally in 14% of heterogeneous tumors. Tumors were designated as homogeneous in 68% and heterogeneous in 32% of grades. The kappa analysis score for overall tumor consistency

  1. Non-linear phenomena in electronic systems consisting of coupled single-electron oscillators

    International Nuclear Information System (INIS)

    Kikombo, Andrew Kilinga; Hirose, Tetsuya; Asai, Tetsuya; Amemiya, Yoshihito

    2008-01-01

    This paper describes non-linear dynamics of electronic systems consisting of single-electron oscillators. A single-electron oscillator is a circuit made up of a tunneling junction and a resistor, and produces simple relaxation oscillation. Coupled with another, single electron oscillators exhibit complex behavior described by a combination of continuous differential equations and discrete difference equations. Computer simulation shows that a double-oscillator system consisting of two coupled oscillators produces multi-periodic oscillation with a single attractor, and that a quadruple-oscillator system consisting of four oscillators also produces multi-periodic oscillation but has a number of possible attractors and takes one of them determined by initial conditions

  2. Generation of static solutions of self-consistent system of Einstein-Maxwell equations

    International Nuclear Information System (INIS)

    Anchikov, A.M.; Daishev, R.A.

    1988-01-01

    The theorem, according to which the static solution of the self-consistent system of the Einstein-Maxwell equations is assigned to energy static solution of the Einstein equations with the arbitrary energy-momentum tensor in the right part, is proved. As a consequence of this theorem, the way of the generation of the static solutions of the self-consistent system of the Einstein-Maxwell equations with charged dust as a source of the vacuum solutions of the Einstein equations is shown

  3. Self-consistent cluster theory for systems with off-diagonal disorder

    International Nuclear Information System (INIS)

    Kaplan, T.; Leath, P.L.; Gray, L.J.; Diehl, H.W.

    1980-01-01

    A self-consistent cluster theory for elementary excitations in systems with diagonal, off-diagonal, and environmental disorder is presented. The theory is developed in augmented space where the configurational average over the disorder is replaced by a ground-state matrix element in a translationally invariant system. The analyticity of the resulting approximate Green's function is proved. Numerical results for the self-consistent single-site and pair approximations are presented for the vibrational and electronic properties of disordered linear chains with diagonal, off-diagonal, and environmental disorder

  4. Integrable motion of curves in self-consistent potentials: Relation to spin systems and soliton equations

    Energy Technology Data Exchange (ETDEWEB)

    Myrzakulov, R.; Mamyrbekova, G.K.; Nugmanova, G.N.; Yesmakhanova, K.R. [Eurasian International Center for Theoretical Physics and Department of General and Theoretical Physics, Eurasian National University, Astana 010008 (Kazakhstan); Lakshmanan, M., E-mail: lakshman@cnld.bdu.ac.in [Centre for Nonlinear Dynamics, School of Physics, Bharathidasan University, Tiruchirapalli 620 024 (India)

    2014-06-13

    Motion of curves and surfaces in R{sup 3} lead to nonlinear evolution equations which are often integrable. They are also intimately connected to the dynamics of spin chains in the continuum limit and integrable soliton systems through geometric and gauge symmetric connections/equivalence. Here we point out the fact that a more general situation in which the curves evolve in the presence of additional self-consistent vector potentials can lead to interesting generalized spin systems with self-consistent potentials or soliton equations with self-consistent potentials. We obtain the general form of the evolution equations of underlying curves and report specific examples of generalized spin chains and soliton equations. These include principal chiral model and various Myrzakulov spin equations in (1+1) dimensions and their geometrically equivalent generalized nonlinear Schrödinger (NLS) family of equations, including Hirota–Maxwell–Bloch equations, all in the presence of self-consistent potential fields. The associated gauge equivalent Lax pairs are also presented to confirm their integrability. - Highlights: • Geometry of continuum spin chain with self-consistent potentials explored. • Mapping on moving space curves in R{sup 3} in the presence of potential fields carried out. • Equivalent generalized nonlinear Schrödinger (NLS) family of equations identified. • Integrability of identified nonlinear systems proved by deducing appropriate Lax pairs.

  5. On dynamically consistent Jacobian inverse for non-holonomic robotic systems

    Directory of Open Access Journals (Sweden)

    Ratajczak Joanna

    2017-12-01

    Full Text Available This paper presents the dynamically consistent Jacobian inverse for non-holonomic robotic system, and its application to solving the motion planning problem. The system’s kinematics are represented by a driftless control system, and defined in terms of its input-output map in accordance with the endogenous configuration space approach. The dynamically consistent Jacobian inverse (DCJI has been introduced by means of a Riemannian metric in the endogenous configuration space, exploiting the reduced inertia matrix of the system’s dynamics. The consistency condition is formulated as the commutativity property of a diagram of maps. Singular configurations of DCJI are studied, and shown to coincide with the kinematic singularities. A parametric form of DCJI is derived, and used for solving example motion planning problems for the trident snake mobile robot. Some advantages in performance of DCJI in comparison to the Jacobian pseudoinverse are discovered.

  6. Consistent adoption of the International System of Units (SI) in nuclear science and technology

    Energy Technology Data Exchange (ETDEWEB)

    Klumpar, J; Kovar, Z [Ceskoslovenska Akademie Ved, Prague. Laborator Radiologicke Dozimetrie; Sacha, J [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Fyzikalny Ustav

    1975-11-01

    The principles are stressed behind a consistent introduction of the International System of Units (SI) in Czechoslovakia complying with the latest edition of the Czechoslovak Standard CSN 01 1300 on the prescribed system of national and international units. The use of special and auxiliary units in nuclear physics and technology is discussed, particular attention being devoted to the units of activity and to the time units applied in radiology. Conversion graph and tables are annexed.

  7. Discretizing LTI Descriptor (Regular Differential Input Systems with Consistent Initial Conditions

    Directory of Open Access Journals (Sweden)

    Athanasios D. Karageorgos

    2010-01-01

    Full Text Available A technique for discretizing efficiently the solution of a Linear descriptor (regular differential input system with consistent initial conditions, and Time-Invariant coefficients (LTI is introduced and fully discussed. Additionally, an upper bound for the error ‖x¯(kT−x¯k‖ that derives from the procedure of discretization is also provided. Practically speaking, we are interested in such kind of systems, since they are inherent in many physical, economical and engineering phenomena.

  8. Chaotic synchronization of vibrations of a coupled mechanical system consisting of a plate and beams

    Directory of Open Access Journals (Sweden)

    J. Awrejcewicz

    Full Text Available In this paper mathematical model of a mechanical system consisting of a plate and either one or two beams is derived. Obtained PDEs are reduced to ODEs, and then studied mainly using the fast Fourier and wavelet transforms. A few examples of the chaotic synchronizations are illustrated and discussed.

  9. Bioactive Glass Nanoparticles as a New Delivery System for Sustained 5-Fluorouracil Release: Characterization and Evaluation of Drug Release Mechanism

    Directory of Open Access Journals (Sweden)

    Abeer M. El-Kady

    2015-01-01

    Full Text Available Bioactive glass nanoparticles were synthesized and tested for the first time as a new delivery system for sustained 5-fluorouracil (5-FU release. They were characterized by TEM, DTA, TGA, and FT-IR. The porosity % and specific surface area of glass nanoparticles were 85.59% and 378.36 m2/g, respectively. The in vitro bioactivity evaluation confirmed that bioactive glass disks prepared from these nanoparticles could induce hydroxyapatite layer over their surfaces in simulated body fluid. The in vitro drug release experiment indicated that glass nanoparticles could serve as long-term local delivery vehicles for sustained 5-FU release. The release profile of 5-FU showed an initial fast release stage followed by a second stage of slower release. The initial burst release of 5-FU in the first day was about 23% (28.92 mg·L−1 of the total amount of loaded 5-FU, while the final cumulative percentage of the 5-FU released after 32 days was about 45.6% (57.31 mg·L−1 of the total amount of loaded 5-FU. The application of different mathematical models indicated that 5-FU was released by diffusion controlled mechanism and suggested that its release rate was dependent on glass particles dissolution, changes of surface area as well as diameter of glass particles, and concentration of loaded drug.

  10. Isoguvacine binding, uptake, and release: relation to the GABA system

    Energy Technology Data Exchange (ETDEWEB)

    White, W F; Snodgrass, S R

    1983-06-01

    Isoguvacine (1,2,3,6-tetrahydropyridine-4-carboxylic acid) is a GABA (gamma-aminobutyric acid) agonist with limited conformational flexibility. In these studies we investigated the binding, uptake, and release of (3H) isoguvacine by use of tissue preparations of rat CNS, comparing the results with similar studies of (3H)GABA. The results from these investigations indicate that isoguvacine binds to membrane preparations of rat forebrain with pharmacological characteristics similar to the post-synaptic GABA recognition site; that it is transported into synaptosomal preparations by an uptake system similar to the high-affinity GABA uptake system; and that recently accumulated isoguvacine is released in a Ca2+-dependent manner and by heteroexchange with external GABA. The ability of isoguvacine and gamma-hydroxybutyric acid to decrease the K+-stimulated Ca2+-dependent release process was also investigated. The results indicate that isoguvacine interactions have many of the biochemical features of GABA synaptic function, isoguvacine being, however, less potent than GABA.

  11. Potential detection systems for monitoring UF6 releases

    International Nuclear Information System (INIS)

    Beck, D.E.; Bostick, W.D.; Armstrong, D.P.; McNeely, J.R.; Stockdale, J.A.D.

    1994-09-01

    In the near future, the Nuclear Regulatory Commission (NRC) will begin to regulate the gaseous diffusion plants. Them is a concern that the smoke detectors currently used for uranium hexafluoride (UF 6 ) release detection will not meet NRC safety system requirements such as high reliability and rapid response. The NRC's position is that licensees should utilize state-of-the-art equipment such as hydrogen fluoride (HF) detectors that would provide more dependable detection of a UF 6 release. A survey of the literature and current vendor information was undertaken to define the state-of-the-art and commercial availability of HF (or other appropriate) detection systems. For the purpose of this report, classification of the available HF detection systems is made on the basis of detection principle (e.g., calorimetric, electrochemical, separational, or optical). Emphasis is also placed on whether the device is primarily sensitive to response from a point source (e.g., outleakage in the immediate vicinity of a specific set of components), or whether the device is potentially applicable to remote sensing over a larger area. Traditional HF point source monitoring typically uses gas sampling tubes or coated paper tapes with color developing indicator, portable and small area HF monitors are often based upon electrochemical or extractive/separational systems; and remote sensing by optical systems holds promise for indoor and outdoor large area monitoring (including plant boundary/ambient air monitoring)

  12. The method and program system CABEI for adjusting consistency between natural element and its isotopes data

    Energy Technology Data Exchange (ETDEWEB)

    Tingjin, Liu; Zhengjun, Sun [Chinese Nuclear Data Center, Beijing, BJ (China)

    1996-06-01

    To meet the requirement of nuclear engineering, especially nuclear fusion reactor, now the data in the major evaluated libraries are given not only for natural element but also for its isotopes. Inconsistency between element and its isotopes data is one of the main problem in present evaluated neutron libraries. The formulas for adjusting to satisfy simultaneously the two kinds of consistent relationships were derived by means of least square method, the program system CABEI were developed. This program was tested by calculating the Fe data in CENDL-2.1. The results show that adjusted values satisfy the two kinds of consistent relationships.

  13. Resurgence of Minimal Stimulation In Vitro Fertilization with A Protocol Consisting of Gonadotropin Releasing Hormone-Agonist Trigger and Vitrified-Thawed Embryo Transfer

    Directory of Open Access Journals (Sweden)

    Zhang John

    2016-07-01

    Full Text Available Minimal stimulation in vitro fertilization (mini-IVF consists of a gentle controlled ovarian stimulation that aims to produce a maximum of five to six oocytes. There is a misbelief that mini-IVF severely compromises pregnancy and live birth rates. An appraisal of the literature pertaining to studies on mini-IVF protocols was performed. The advantages of minimal stimulation protocols are reported here with a focus on the use of clomiphene citrate (CC, gonadotropin releasing hormone (GnRH ago- nist trigger for oocyte maturation, and freeze-all embryo strategy. Literature review and the author’s own center data suggest that minimal ovarian stimulation protocols with GnRH agonist trigger and freeze-all embryo strategy along with single embryo transfer produce a reasonable clinical pregnancy and live birth rates in both good and poor responders. Additionally, mini-IVF offers numerous advantages such as: i. Reduction in cost and stress with fewer office visits, needle sticks, and ultrasounds, and ii. Reduction in the incidence of ovarian hyperstimulation syndrome (OHSS. Mini-IVF is re-emerging as a solution for some of the problems associated with conventional IVF, such as OHSS, cost, and patient discomfort.

  14. New polyvinyl chloride (PVC) nanocomposite consisting of aromatic polyamide and chitosan modified ZnO nanoparticles with enhanced thermal stability, low heat release rate and improved mechanical properties

    Science.gov (United States)

    Hajibeygi, Mohsen; Maleki, Mahdiye; Shabanian, Meisam; Ducos, Franck; Vahabi, Henri

    2018-05-01

    New ternary nanocomposite systems containing polylvinyl chloride (PVC), chitosan modified ZnO (CMZN) nanoparticles and new synthesized polyamide (PA) were designed and prepared by solution casting method. As a potential reinforcement, CMZN was used in PVC system combined with and without PA. Morphology, mechanical, thermal and combustion properties of the all PVC systems were studied. In the presence of the CMZN, PA showed a synergistic effect on improvement of the all investigated properties of PVC. The 5 mass% loss temperature (T5) was increased from 195 °C to 243 °C in PVC/CMZN-PA nanocomposite containing 1 mass% of each PA and CMZN (PZP 2). The peak of heat release rate was decreased from 131 W/g for PVC to 104 W/g for PVC/CMZN-PA nanocomposite containing 3 mass% of each PA and CMZN (PZP 6). According to the tensile tests, compared to the neat PVC, the tensile strength was increased from 35.4 to 53.4 MPa for PZP 6.

  15. The potential for intelligent decision support systems to improve the quality and consistency of medication reviews.

    Science.gov (United States)

    Bindoff, I; Stafford, A; Peterson, G; Kang, B H; Tenni, P

    2012-08-01

    Drug-related problems (DRPs) are of serious concern worldwide, particularly for the elderly who often take many medications simultaneously. Medication reviews have been demonstrated to improve medication usage, leading to reductions in DRPs and potential savings in healthcare costs. However, medication reviews are not always of a consistently high standard, and there is often room for improvement in the quality of their findings. Our aim was to produce computerized intelligent decision support software that can improve the consistency and quality of medication review reports, by helping to ensure that DRPs relevant to a patient are overlooked less frequently. A system that largely achieved this goal was previously published, but refinements have been made. This paper examines the results of both the earlier and newer systems. Two prototype multiple-classification ripple-down rules medication review systems were built, the second being a refinement of the first. Each of the systems was trained incrementally using a human medication review expert. The resultant knowledge bases were analysed and compared, showing factors such as accuracy, time taken to train, and potential errors avoided. The two systems performed well, achieving accuracies of approximately 80% and 90%, after being trained on only a small number of cases (126 and 244 cases, respectively). Through analysis of the available data, it was estimated that without the system intervening, the expert training the first prototype would have missed approximately 36% of potentially relevant DRPs, and the second 43%. However, the system appeared to prevent the majority of these potential expert errors by correctly identifying the DRPs for them, leaving only an estimated 8% error rate for the first expert and 4% for the second. These intelligent decision support systems have shown a clear potential to substantially improve the quality and consistency of medication reviews, which should in turn translate into

  16. Seeing the System through the End Users' Eyes: Shadow Expert Technique for Evaluating the Consistency of a Learning Management System

    Science.gov (United States)

    Holzinger, Andreas; Stickel, Christian; Fassold, Markus; Ebner, Martin

    Interface consistency is an important basic concept in web design and has an effect on performance and satisfaction of end users. Consistency also has significant effects on the learning performance of both expert and novice end users. Consequently, the evaluation of consistency within a e-learning system and the ensuing eradication of irritating discrepancies in the user interface redesign is a big issue. In this paper, we report of our experiences with the Shadow Expert Technique (SET) during the evaluation of the consistency of the user interface of a large university learning management system. The main objective of this new usability evaluation method is to understand the interaction processes of end users with a specific system interface. Two teams of usability experts worked independently from each other in order to maximize the objectivity of the results. The outcome of this SET method is a list of recommended changes to improve the user interaction processes, hence to facilitate high consistency.

  17. Development of controlled drug release systems based on thiolated polymers.

    Science.gov (United States)

    Bernkop-Schnürch, A; Scholler, S; Biebel, R G

    2000-05-03

    The purpose of the present study was to generate mucoadhesive matrix-tablets based on thiolated polymers. Mediated by a carbodiimide, L-cysteine was thereby covalently linked to polycarbophil (PCP) and sodium carboxymethylcellulose (CMC). The resulting thiolated polymers displayed 100+/-8 and 1280+/-84 micromol thiol groups per gram, respectively (means+/-S.D.; n=6-8). In aqueous solutions these modified polymers were capable of forming inter- and/or intramolecular disulfide bonds. The velocity of this process augmented with increase of the polymer- and decrease of the proton-concentration. The oxidation proceeded more rapidly within thiolated PCP than within thiolated CMC. Due to the formation of disulfide bonds within thiol-containing polymers, the stability of matrix-tablets based on such polymers could be strongly improved. Whereas tablets based on the corresponding unmodified polymer disintegrated within 2 h, the swollen carrier matrix of thiolated CMC and PCP remained stable for 6.2 h (mean, n=4) and more than 48 h, respectively. Release studies of the model drug rifampicin demonstrated that a controlled release can be provided by thiolated polymer tablets. The combination of high stability, controlled drug release and mucoadhesive properties renders matrix-tablets based on thiolated polymers useful as novel drug delivery systems.

  18. RELIABILITY ASSESSMENT OF ENTROPY METHOD FOR SYSTEM CONSISTED OF IDENTICAL EXPONENTIAL UNITS

    Institute of Scientific and Technical Information of China (English)

    Sun Youchao; Shi Jun

    2004-01-01

    The reliability assessment of unit-system near two levels is the most important content in the reliability multi-level synthesis of complex systems. Introducing the information theory into system reliability assessment, using the addible characteristic of information quantity and the principle of equivalence of information quantity, an entropy method of data information conversion is presented for the system consisted of identical exponential units. The basic conversion formulae of entropy method of unit test data are derived based on the principle of information quantity equivalence. The general models of entropy method synthesis assessment for system reliability approximate lower limits are established according to the fundamental principle of the unit reliability assessment. The applications of the entropy method are discussed by way of practical examples. Compared with the traditional methods, the entropy method is found to be valid and practicable and the assessment results are very satisfactory.

  19. Drug delivery systems with modified release for systemic and biophase bioavailability.

    Science.gov (United States)

    Leucuta, Sorin E

    2012-11-01

    This review describes the most important new generations of pharmaceutical systems: medicines with extended release, controlled release pharmaceutical systems, pharmaceutical systems for the targeted delivery of drug substances. The latest advances and approaches for delivering small molecular weight drugs and other biologically active agents such as proteins and nucleic acids require novel delivery technologies, the success of a drug being many times dependent on the delivery method. All these dosage forms are qualitatively superior to medicines with immediate release, in that they ensure optimal drug concentrations depending on specific demands of different disease particularities of the body. Drug delivery of these pharmaceutical formulations has the benefit of improving product efficacy and safety, as well as patient convenience and compliance. This paper describes the biopharmaceutical, pharmacokinetic, pharmacologic and technological principles in the design of drug delivery systems with modified release as well as the formulation criteria of prolonged and controlled release drug delivery systems. The paper presents pharmaceutical prolonged and controlled release dosage forms intended for different routes of administration: oral, ocular, transdermal, parenteral, pulmonary, mucoadhesive, but also orally fast dissolving tablets, gastroretentive drug delivery systems, colon-specific drug delivery systems, pulsatile drug delivery systems and carrier or ligand mediated transport for site specific or receptor drug targeting. Specific technologies are given on the dosage forms with modified release as well as examples of marketed products, and current research in these areas.

  20. Nonlocal Symmetries, Consistent Riccati Expansion, and Analytical Solutions of the Variant Boussinesq System

    Science.gov (United States)

    Feng, Lian-Li; Tian, Shou-Fu; Zhang, Tian-Tian; Zhou, Jun

    2017-07-01

    Under investigation in this paper is the variant Boussinesq system, which describes the propagation of surface long wave towards two directions in a certain deep trough. With the help of the truncated Painlevé expansion, we construct its nonlocal symmetry, Bäcklund transformation, and Schwarzian form, respectively. The nonlocal symmetries can be localised to provide the corresponding nonlocal group, and finite symmetry transformations and similarity reductions are computed. Furthermore, we verify that the variant Boussinesq system is solvable via the consistent Riccati expansion (CRE). By considering the consistent tan-function expansion (CTE), which is a special form of CRE, the interaction solutions between soliton and cnoidal periodic wave are explicitly studied.

  1. Radiation crosslinked hydrogels as sustained release drug delivery systems

    International Nuclear Information System (INIS)

    Pekala, W.; Rosiak, J.; Rucinska-Rybus, A.; Burczak, K.; Galant, S.; Czolczynska, T.

    1986-01-01

    Radiation methods have been used for: i/modification of vascular prostheses, ii/ obtaining burn dressing materials enabling controlled drug release, iii/ the preparation of polymer ocular insert discs. The surface of polyester vascular prostheses, has been modified by deposition of acrylamide and inducing its polymerization in the solid state by γ-radiation. As a result of this treatment, tightness of the prosthesis walls and its surface hydrophilicity have been improved. Toxicological examinations and blood hemolysis studies of modified prostheses showed its good biocompatibility. Various burn dressings have been prepared and the most promising of all investigated turned to be composition consisting of a cotton gauze base and an active polyacrylamide hydrogel layer with addition of glycerin and immobilized Provital/protein preparation/. Preliminary clinical evaluations of this particular dressing showed that the process of burn healing is indeed fast and fully satisfactory. Ocular insert discs made of polymer and containing pilocarpin hydrochloride which is released at controlled rate have been prepared. It has been found that high hydrophilicity and good swelling properties of the ocular insert discs made possible to incorporate pilocarpin hydrochloride into hydrogel matrix. This work has been carried out under IAEA research contract RB 3379/R-1 POL. (author)

  2. Ring retroreflector system consisting of cube-corner reflectors with special coating

    International Nuclear Information System (INIS)

    Burmistrov, V B; Sadovnikov, M A; Sokolov, A L; Shargorodskiy, V D

    2013-01-01

    The ring retroreflector system (RS) consisting of cubecorner reflectors (CCRs) with a special coating of reflecting surfaces, intended for uniaxially Earth-oriented navigation satellites, is considered. The error of distance measurement caused by both the laser pulse delay in the CCR and its spatial position (CCR configuration) is studied. It is shown that the ring RS, formed by the CCR with a double-spot radiation pattern, allows the distance measurement error to be essentially reduced. (nanogradient dielectric coatings and metamaterials)

  3. Calibration and consistency of results of an ionization-chamber secondary standard measuring system for activity

    International Nuclear Information System (INIS)

    Schrader, Heinrich

    2000-01-01

    Calibration in terms of activity of the ionization-chamber secondary standard measuring systems at the PTB is described. The measurement results of a Centronic IG12/A20, a Vinten ISOCAL IV and a radionuclide calibrator chamber for nuclear medicine applications are discussed, their energy-dependent efficiency curves established and the consistency checked using recently evaluated radionuclide decay data. Criteria for evaluating and transferring calibration factors (or efficiencies) are given

  4. The Consistency of Performance Management System Based on Attributes of the Performance Indicator: An Empirical Study

    Directory of Open Access Journals (Sweden)

    Jan Zavadsky

    2014-07-01

    Full Text Available Purpose: The performance management system (PMS is a metasystem over all business processes at the strategic and operational level. Effectiveness of the various management systems depends on many factors. One of them is the consistent definition of each system elements. The main purpose of this study is to explore if the performance management systems of the sample companies is consistent and how companies can create such a system. The consistency in this case is based on the homogenous definition of attributes relating to the performance indicator as a basic element of PMS.Methodology: At the beginning, we used an affinity diagram that helped us to clarify and to group various attributes of performance indicators. The main research results we achieved are through empirical study. The empirical study was carried out in a sample of Slovak companies. The criterion for selection was the existence of the certified management systems according to the ISO 9001. Representativeness of the sample companies was confirmed by application of Pearson´s chi-squared test (χ2 - test due to above standards. Findings: Coming from the review of various literature, we defined four groups of attributes relating to the performance indicator: formal attributes, attributes of target value, informational attributes and attributes of evaluation. The whole set contains 21 attributes. The consistency of PMS is based not on maximum or minimum number of attributes, but on the same type of attributes for each performance indicator used in PMS at both the operational and strategic level. The main findings are: companies use various financial and non-financial indicators at strategic or operational level; companies determine various attributes of performance indicator, but most of the performance indicators are otherwise determined; we identified the common attributes for the whole sample of companies. Practical implications: The research results have got an implication for

  5. Bosons system with finite repulsive interaction: self-consistent field method

    International Nuclear Information System (INIS)

    Renatino, M.M.B.

    1983-01-01

    Some static properties of a boson system (T = zero degree Kelvin), under the action of a repulsive potential are studied. For the repulsive potential, a model was adopted consisting of a region where it is constant (r c ), and a decay as 1/r (r > r c ). The self-consistent field approximation used takes into account short range correlations through a local field corrections, which leads to an effective field. The static structure factor S(q-vector) and the effective potential ψ(q-vector) are obtained through a self-consistent calculation. The pair-correlation function g(r-vector) and the energy of the collective excitations E(q-vector) are also obtained, from the structure factor. The density of the system and the parameters of the repulsive potential, that is, its height and the size of the constant region were used as variables for the problem. The results obtained for S(q-vector), g(r-vector) and E(q-vector) for a fixed ratio r o /r c and a variable λ, indicates the raising of a system structure, which is more noticeable when the potential became more repulsive. (author)

  6. Environmental system applied to radioactive liquid effluent release

    International Nuclear Information System (INIS)

    Nisti, Marcelo Bessa

    2009-01-01

    The current environmental administration considers the productive activity as an environmental system, defined as a group of processes, interactions, parameters and factors involved in the production. This mastering dissertation evaluated the release of the liquid radioactive effluents at Instituto de Pesquisas Energeticas e Nucleares (IPEN), under a systemic environmental study. The study evaluated the source term at IPEN in the period from 2004 to 2008, making use of gamma-ray and alpha spectrometry, instrumental neutron activation analysis, liquid phase scintillation and atomic absorption spectrometry. The employed methodologies were verified using samples from the Intercomparison National Program - PNI/IRD and Reference Materials. The facilities that contributed the most in these releases were the Radiopharmaceutical Center (CR) and the Research Reactor Center (CRPq) with an average of 11,4% and 87,4%, respectively, relative to the present radioactive activity. The sewer system releases were within the radioactive protection regulations, showing the effectiveness of IPEN's Radioactive Effluents Monitoring Program. The concentration of the stable elements Ag, Cd, Cr, Fe, Mn, Ni, Pb and Zn was determined in the liquid effluent in ali the samples from the storage tanks TR1 and CR in the period from 2004 to 2008 and in some of the samples of other IPEN's facilities in the period from 2004 to 2007. Among the analyzed effluents, two samples were higher than the stable elements discharge standards established in the state of Sao Paulo, one sample was higher than the required value of the element cadmium and the other higher than required value of the element zinco The storage tank TR1 discharge flow was estimated in 10,9 ± 0,9 m3 h -1 . The dilution factor at discharge point E1 was estimated using a radiotracers the isotopes 3 H, 137 CS, 60 Co, 54 Mn and 65 Zn, which are commonly released into IPEN's sewer system. The executed radiotracer study was carried out

  7. Decision support system for containment and release management

    Energy Technology Data Exchange (ETDEWEB)

    Oosterhuis, B [Twente Univ., Enschede (Netherlands). Computer Science Dept.

    1995-09-01

    The Containment and Release Management project was carried out within the Reinforced Concerted Action Programme for Accident Management Support and partly financed by the European Union. In this report a prototype of an accident management support system is presented. The support system integrates several concepts from accident management research, like safety objective trees, severe accident phenomena, calculation models and an emergency response data system. These concepts are provided by the prototype in such a way that the decision making process of accident management is supported. The prototype application is demonstrated by process data taken from a severe accident scenario for a pressurized water reactor (PWR) that was simulated with the thermohydraulic computer program MAAP. The prototype was derived from a decision support framework based on a decision theory. For established and innovative concepts from accident management research it is pointed out in which way these concepts can support accident management and how these concepts can be integrated. This approach is generic in two ways; it applies to both pressurized and boiling water reactors and it applies to both in vessel management and containment and release management. The prototype application was developed in Multimedia Toolbox 3.0 and requires at least a 386 PC with 4 MB memory, 6 MB free disk space and MS Windows 3.1. (orig.).

  8. Decision support system for containment and release management

    International Nuclear Information System (INIS)

    Oosterhuis, B.

    1995-09-01

    The Containment and Release Management project was carried out within the Reinforced Concerted Action Programme for Accident Management Support and partly financed by the European Union. In this report a prototype of an accident management support system is presented. The support system integrates several concepts from accident management research, like safety objective trees, severe accident phenomena, calculation models and an emergency response data system. These concepts are provided by the prototype in such a way that the decision making process of accident management is supported. The prototype application is demonstrated by process data taken from a severe accident scenario for a pressurized water reactor (PWR) that was simulated with the thermohydraulic computer program MAAP. The prototype was derived from a decision support framework based on a decision theory. For established and innovative concepts from accident management research it is pointed out in which way these concepts can support accident management and how these concepts can be integrated. This approach is generic in two ways; it applies to both pressurized and boiling water reactors and it applies to both in vessel management and containment and release management. The prototype application was developed in Multimedia Toolbox 3.0 and requires at least a 386 PC with 4 MB memory, 6 MB free disk space and MS Windows 3.1. (orig.)

  9. Contact lenses as drug controlled release systems: a narrative review

    Directory of Open Access Journals (Sweden)

    Helena Prior Filipe

    2016-06-01

    Full Text Available ABSTRACT Topically applied therapy is the most common way to treat ocular diseases, however given the anatomical and physiological constraints of the eye, frequent dosing is required with possible repercussions in terms of patient compliance. Beyond refractive error correction, contact lenses (CLs have, in the last few decades emerged as a potential ophthalmic drug controlled release system (DCRS. Extensive research is underway to understand how to best modify CLs to increase residence time and bioavailability of drugs within therapeutic levels on the ocular surface.These devices may simultaneously correct ametropia and have a role in managing ophthalmic disorders that can hinder CL wear such as dry eye, glaucoma, ocular allergy and cornea infection and injury. In this narrative review the authors explain how the ocular surface structures determine drug diffusion in the eye and summarize the strategies to enhance drug residence time and bioavailability. They synthesize findings and clinical applications of drug soaked CLs as DCRS combined with delivery diffusion barriers, incorporation of functional monomers, ion related controlled release, molecular imprinting, nanoparticles and layering. The authors draw conclusions about the impact of these novel ophthalmic agents delivery systems in improving drug transport in the target tissue and patient compliance, in reducing systemic absorption and undesired side effects, and discuss future perspectives.

  10. Synchronization in node of complex networks consist of complex chaotic system

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Qiang, E-mail: qiangweibeihua@163.com [Beihua University computer and technology College, BeiHua University, Jilin, 132021, Jilin (China); Digital Images Processing Institute of Beihua University, BeiHua University, Jilin, 132011, Jilin (China); Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, Dalian, 116024 (China); Xie, Cheng-jun [Beihua University computer and technology College, BeiHua University, Jilin, 132021, Jilin (China); Digital Images Processing Institute of Beihua University, BeiHua University, Jilin, 132011, Jilin (China); Liu, Hong-jun [School of Information Engineering, Weifang Vocational College, Weifang, 261041 (China); Li, Yan-hui [The Library, Weifang Vocational College, Weifang, 261041 (China)

    2014-07-15

    A new synchronization method is investigated for node of complex networks consists of complex chaotic system. When complex networks realize synchronization, different component of complex state variable synchronize up to different scaling complex function by a designed complex feedback controller. This paper change synchronization scaling function from real field to complex field for synchronization in node of complex networks with complex chaotic system. Synchronization in constant delay and time-varying coupling delay complex networks are investigated, respectively. Numerical simulations are provided to show the effectiveness of the proposed method.

  11. The self-consistent field model for Fermi systems with account of three-body interactions

    Directory of Open Access Journals (Sweden)

    Yu.M. Poluektov

    2015-12-01

    Full Text Available On the basis of a microscopic model of self-consistent field, the thermodynamics of the many-particle Fermi system at finite temperatures with account of three-body interactions is built and the quasiparticle equations of motion are obtained. It is shown that the delta-like three-body interaction gives no contribution into the self-consistent field, and the description of three-body forces requires their nonlocality to be taken into account. The spatially uniform system is considered in detail, and on the basis of the developed microscopic approach general formulas are derived for the fermion's effective mass and the system's equation of state with account of contribution from three-body forces. The effective mass and pressure are numerically calculated for the potential of "semi-transparent sphere" type at zero temperature. Expansions of the effective mass and pressure in powers of density are obtained. It is shown that, with account of only pair forces, the interaction of repulsive character reduces the quasiparticle effective mass relative to the mass of a free particle, and the attractive interaction raises the effective mass. The question of thermodynamic stability of the Fermi system is considered and the three-body repulsive interaction is shown to extend the region of stability of the system with the interparticle pair attraction. The quasiparticle energy spectrum is calculated with account of three-body forces.

  12. General approach to the testing of binary solubility systems for thermodynamic consistency. Consolidated Fuel Reprocessing Program

    International Nuclear Information System (INIS)

    Hamm, L.L.; Van Brunt, V.

    1982-08-01

    A comparison of implicit Runge-Kutta and orthogonal collocation methods is made for the numerical solution to the ordinary differential equation which describes the high-pressure vapor-liquid equilibria of a binary system. The systems of interest are limited to binary solubility systems where one of the components is supercritical and exists as a noncondensable gas in the pure state. Of the two methods - implicit Runge-Kuta and orthogonal collocation - this paper attempts to present some preliminary but not necessarily conclusive results that the implicit Runge-Kutta method is superior for the solution to the ordinary differential equation utilized in the thermodynamic consistency testing of binary solubility systems. Due to the extreme nonlinearity of thermodynamic properties in the region near the critical locus, an extended cubic spline fitting technique is devised for correlating the P-x data. The least-squares criterion is employed in smoothing the experimental data. Even though the derivation is presented specifically for the correlation of P-x data, the technique could easily be applied to any thermodynamic data by changing the endpoint requirements. The volumetric behavior of the systems must be given or predicted in order to perform thermodynamic consistency tests. A general procedure is developed for predicting the volumetric behavior required and some indication as to the expected limit of accuracy is given

  13. Incorporating rapid neocortical learning of new schema-consistent information into complementary learning systems theory.

    Science.gov (United States)

    McClelland, James L

    2013-11-01

    The complementary learning systems theory of the roles of hippocampus and neocortex (McClelland, McNaughton, & O'Reilly, 1995) holds that the rapid integration of arbitrary new information into neocortical structures is avoided to prevent catastrophic interference with structured knowledge representations stored in synaptic connections among neocortical neurons. Recent studies (Tse et al., 2007, 2011) showed that neocortical circuits can rapidly acquire new associations that are consistent with prior knowledge. The findings challenge the complementary learning systems theory as previously presented. However, new simulations extending those reported in McClelland et al. (1995) show that new information that is consistent with knowledge previously acquired by a putatively cortexlike artificial neural network can be learned rapidly and without interfering with existing knowledge; it is when inconsistent new knowledge is acquired quickly that catastrophic interference ensues. Several important features of the findings of Tse et al. (2007, 2011) are captured in these simulations, indicating that the neural network model used in McClelland et al. has characteristics in common with neocortical learning mechanisms. An additional simulation generalizes beyond the network model previously used, showing how the rate of change of cortical connections can depend on prior knowledge in an arguably more biologically plausible network architecture. In sum, the findings of Tse et al. are fully consistent with the idea that hippocampus and neocortex are complementary learning systems. Taken together, these findings and the simulations reported here advance our knowledge by bringing out the role of consistency of new experience with existing knowledge and demonstrating that the rate of change of connections in real and artificial neural networks can be strongly prior-knowledge dependent. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  14. Design of micro distribution systems consisting of long channels with arbitrary cross sections

    International Nuclear Information System (INIS)

    Misdanitis, S; Valougeorgis, D

    2012-01-01

    Gas flows through long micro-channels of various cross sections have been extensively investigated over the years both numerically and experimentally. In various technological applications including microfluidics, these micro-channels are combined together in order to form a micro-channel network. Computational algorithms for solving gas pipe networks in the hydrodynamic regime are well developed. However, corresponding tools for solving networks consisting of micro-channels under any degree of gas rarefaction is very limited. Recently a kinetic algorithm has been developed to simulate gas distribution systems consisting of long circular channels under any vacuum conditions. In the present work this algorithm is generalized and extended into micro-channels of arbitrary cross-section etched by KOH in silicon (triangular and trapezoidal channels with acute angle of 54.74°). Since a kinetic approach is implemented, the analysis is valid and the results are accurate in the whole range of the Knudsen number, while the involved computational effort is very small. This is achieved by successfully integrating the kinetic results for the corresponding single channels into the general solver for designing the gas pipe network. To demonstrate the feasibility of the approach two typical systems consisting of long rectangular and trapezoidal micro-channels are solved.

  15. Convective plasma stability consistent with MHD equilibrium in magnetic confinement systems with a decreasing field

    International Nuclear Information System (INIS)

    Tsventoukh, M. M.

    2010-01-01

    A study is made of the convective (interchange, or flute) plasma stability consistent with equilibrium in magnetic confinement systems with a magnetic field decreasing outward and large curvature of magnetic field lines. Algorithms are developed which calculate convective plasma stability from the Kruskal-Oberman kinetic criterion and in which the convective stability is iteratively consistent with MHD equilibrium for a given pressure and a given type of anisotropy in actual magnetic geometry. Vacuum and equilibrium convectively stable configurations in systems with a decreasing, highly curved magnetic field are calculated. It is shown that, in convectively stable equilibrium, the possibility of achieving high plasma pressures in the central region is restricted either by the expansion of the separatrix (when there are large regions of a weak magnetic field) or by the filamentation of the gradient plasma current (when there are small regions of a weak magnetic field, in which case the pressure drops mainly near the separatrix). It is found that, from the standpoint of equilibrium and of the onset of nonpotential ballooning modes, a kinetic description of convective stability yields better plasma confinement parameters in systems with a decreasing, highly curved magnetic field than a simpler MHD model and makes it possible to substantially improve the confinement parameters for a given type of anisotropy. For the Magnetor experimental compact device, the maximum central pressure consistent with equilibrium and stability is calculated to be as high as β ∼ 30%. It is shown that, for the anisotropy of the distribution function that is typical of a background ECR plasma, the limiting pressure gradient is about two times steeper than that for an isotropic plasma. From a practical point of view, the possibility is demonstrated of achieving better confinement parameters of a hot collisionless plasma in systems with a decreasing, highly curved magnetic field than those

  16. Design of next step tokamak: Consistent analysis of plasma performance flux composition and poloidal field system

    International Nuclear Information System (INIS)

    Ane, J.M.; Grandgirard, V.; Albajar, F.; Johner, J.

    2001-01-01

    A consistent and simple approach to derive plasma scenarios for next step tokamak design is presented. It is based on successive plasma equilibria snapshots from plasma breakdown to end of ramp-down. Temperature and density profiles for each equilibrium are derived from a 2D plasma model. The time interval between two successive equilibria is then computed from the toroidal field magnetic energy balance, the resistive term of which depends on n, T profiles. This approach provides a consistent analysis of plasma performance, flux consumption and PF system, including average voltages waveforms across the PF coils. The plasma model and the Poynting theorem for the toroidal magnetic energy are presented. Application to ITER-FEAT and to M2, a Q=5 machine designed at CEA, are shown. (author)

  17. Self-consistent theory of finite Fermi systems and radii of nuclei

    International Nuclear Information System (INIS)

    Saperstein, E. E.; Tolokonnikov, S. V.

    2011-01-01

    Present-day self-consistent approaches in nuclear theory were analyzed from the point of view of describing distributions of nuclear densities. The generalized method of the energy density functional due to Fayans and his coauthors (this is the most successful version of the self-consistent theory of finite Fermi systems) was the first among the approaches under comparison. The second was the most successful version of the Skyrme-Hartree-Fock method with the HFB-17 functional due to Goriely and his coauthors. Charge radii of spherical nuclei were analyzed in detail. Several isotopic chains of deformed nuclei were also considered. Charge-density distributions ρ ch (r) were calculated for several spherical nuclei. They were compared with model-independent data extracted from an analysis of elastic electron scattering on nuclei.

  18. Self-consistent field theory based molecular dynamics with linear system-size scaling

    Energy Technology Data Exchange (ETDEWEB)

    Richters, Dorothee [Institute of Mathematics and Center for Computational Sciences, Johannes Gutenberg University Mainz, Staudinger Weg 9, D-55128 Mainz (Germany); Kühne, Thomas D., E-mail: kuehne@uni-mainz.de [Institute of Physical Chemistry and Center for Computational Sciences, Johannes Gutenberg University Mainz, Staudinger Weg 7, D-55128 Mainz (Germany); Technical and Macromolecular Chemistry, University of Paderborn, Warburger Str. 100, D-33098 Paderborn (Germany)

    2014-04-07

    We present an improved field-theoretic approach to the grand-canonical potential suitable for linear scaling molecular dynamics simulations using forces from self-consistent electronic structure calculations. It is based on an exact decomposition of the grand canonical potential for independent fermions and does neither rely on the ability to localize the orbitals nor that the Hamilton operator is well-conditioned. Hence, this scheme enables highly accurate all-electron linear scaling calculations even for metallic systems. The inherent energy drift of Born-Oppenheimer molecular dynamics simulations, arising from an incomplete convergence of the self-consistent field cycle, is circumvented by means of a properly modified Langevin equation. The predictive power of the present approach is illustrated using the example of liquid methane under extreme conditions.

  19. On optimization of an experimental system consisting of beam guidance and nuclear detectors

    International Nuclear Information System (INIS)

    Lehr, H.; Hinderer, G.; Maier, K.H.

    1978-02-01

    This report deals with the optimization of the resolution in nuclear physics experiments with a beam of accelerated particles. The complete system consisting of the beam handling, the nuclear reaction, and the particle detection is described with a linear matrix formalism. This allows to give analytic expressions for the linewidth of any physically interesting quantities, like Q-values of scattering angle in the center of mass system, as a function of beam line-, nuclear reaction-, and spectrometer parameters. From this then general prescriptions for optimizing the resolution by matching the beam handling and the detector system are derived. Explicitly treated are the measurements of Q-values and CM-scattering angle with an energy sensitive detector, a time of flight spectrometer, and a magnetic spectrometer. (orig.) [de

  20. General variational many-body theory with complete self-consistency for trapped bosonic systems

    International Nuclear Information System (INIS)

    Streltsov, Alexej I.; Alon, Ofir E.; Cederbaum, Lorenz S.

    2006-01-01

    In this work we develop a complete variational many-body theory for a system of N trapped bosons interacting via a general two-body potential. The many-body solution of this system is expanded over orthogonal many-body basis functions (configurations). In this theory both the many-body basis functions and the respective expansion coefficients are treated as variational parameters. The optimal variational parameters are obtained self-consistently by solving a coupled system of noneigenvalue--generally integro-differential--equations to get the one-particle functions and by diagonalizing the secular matrix problem to find the expansion coefficients. We call this theory multiconfigurational Hartree theory for bosons or MCHB(M), where M specifies explicitly the number of one-particle functions used to construct the configurations. General rules for evaluating the matrix elements of one- and two-particle operators are derived and applied to construct the secular Hamiltonian matrix. We discuss properties of the derived equations. We show that in the limiting cases of one configuration the theory boils down to the well-known Gross-Pitaevskii and the recently developed multi-orbital mean fields. The invariance of the complete solution with respect to unitary transformations of the one-particle functions is utilized to find the solution with the minimal number of contributing configurations. In the second part of our work we implement and apply the developed theory. It is demonstrated that for any practical computation where the configurational space is restricted, the description of trapped bosonic systems strongly depends on the choice of the many-body basis set used, i.e., self-consistency is of great relevance. As illustrative examples we consider bosonic systems trapped in one- and two-dimensional symmetric and asymmetric double well potentials. We demonstrate that self-consistency has great impact on the predicted physical properties of the ground and excited states

  1. Comodulation masking release in bit-rate reduction systems

    DEFF Research Database (Denmark)

    Vestergaard, Martin David; Rasmussen, Karsten Bo; Poulsen, Torben

    1999-01-01

    It has been suggested that the level dependence of the upper masking slope be utilized in perceptual models in bit-rate reduction systems. However, comodulation masking release (CMR) phenomena lead to a reduction of the masking effect when a masker and a probe signal are amplitude modulated...... with the same frequency. In bit-rate reduction systems the masker would be the audio signal and the probe signal would represent the quantization noise. Masking curves have been determined for sinusoids and 1-Bark-wide noise maskers in order to investigate the risk of CMR, when quantizing depths are fixed...... in accordance with psycho-acoustical principles. Masker frequencies of 500 Hz, 1 kHz, and 2 kHz have been investigated, and the masking of pure tone probes has been determined in the first four 1/3 octaves above the masker. Modulation frequencies between 6 and 20 Hz were used with a modulation depth of 0...

  2. The self-consistent energy system with an enhanced non-proliferated core concept for global nuclear energy utilization

    International Nuclear Information System (INIS)

    Kawashima, Masatoshi; Arie, Kazuo; Araki, Yoshio; Sato, Mitsuyoshi; Mori, Kenji; Nakayama, Yoshiyuki; Nakazono, Ryuichi; Kuroda, Yuji; Ishiguma, Kazuo; Fujii-e, Yoichi

    2008-01-01

    A sustainable nuclear energy system was developed based on the concept of Self-Consistent Nuclear Energy System (SCNES). Our study that trans-uranium (TRU) metallic fuel fast reactor cycle coupled with recycling of five long-lived fission products (LLFP) as well as actinides is the most promising system for the sustainable nuclear utilization. Efficient utilization of uranium-238 through the SCNES concept opens the doors to prolong the lifetime of nuclear energy systems towards several tens of thousand years. Recent evolution of the concept revealed compatibility of fuel sustainability, minor actinide (MA) minimization and non-proliferation aspects for peaceful use of nuclear energy systems through the discussion. As for those TRU compositions stabilized under fast neutron spectra, plutonium isotope fractions are remained in the range of reactor grade classification with high fraction of Pu240 isotope. Recent evolution of the SCNES concept has revealed that TRU recycling can cope with enhancing non-proliferation efforts in peaceful use with the 'no-blanket and multi-zoning core' concept. Therefore, the realization of SCNES is most important. In addition, along the process to the goals, a three-step approach is proposed to solve concurrent problems raised in the LWR systems. We discussed possible roles and contribution to the near future demand along worldwide expansion of LWR capacities by applying the 1st generation SCNES. MA fractions in TRU are more than 10% from LWR discharged fuels and even higher up to 20% in fuels from long interim storages. TRU recycling in the 1st generation SCNES system can reduce the MA fractions down to 4-5% in a few decades. This capability significantly releases 'MA' pressures in down-stream of LWR systems. Current efforts for enhancing capabilities for energy generation by LWR systems are efficient against the global warming crisis. In parallel to those movements, early realization of the SCNES concept can be the most viable decision

  3. Surveillance of hazardous substances releases due to system interruptions, 2002.

    Science.gov (United States)

    Orr, Maureen F; Ruckart, Perri Zeitz

    2007-04-11

    The Hazardous Substances Emergency Events Surveillance (HSEES) system collected information on 9014 acute hazardous substance releases in 15 participating states in 2002. There were 3749 fixed-facility manufacturing events, of which 2100 involved "interruptions" to normal processing and 1649 "comparisons" that did not involve interruption. Equipment failure (69%) or intentional acts (20%) were the main root factor. Many events occurred in October and November in three states (Texas, Louisiana, and New Jersey), in three manufacturing industries (industrial and miscellaneous chemicals; petroleum refining; and plastics, synthetics, and resins). In interruption events, the substance categories most often released were mixtures, other inorganic substances, and volatile organic compounds and those most often causing injury were acids, chlorine, bases, and ammonia. Comparison events resulted in more acutely injured persons (408 versus 59) and more evacuees (11,318 versus 335) than interruption events and therefore may receive more public health attention. Because of the large number of interruption events, targeted prevention activities, including management of change procedures, lessons-learned implementation, process hazards analysis, and appropriate protection for workers could be economically advantageous and improve environmental quality. Efforts should focus on the identified areas of greater occurrence. The relationship of weather and equipment failure with interruption events needs further investigation.

  4. A feasibility study on FP transmutation for Self-Consistent Nuclear Energy System (SCNES)

    International Nuclear Information System (INIS)

    Fujita, Reiko; Kawashima, Masatoshi; Ueda, Hiroaki; Takagi, Ryuzo; Matsuura, Haruaki; Fujii-e, Yoichi

    1997-01-01

    A fast reactor core/fuel cycle concept is discussed for the future 'Self-Consistent Nuclear Energy System (SCNES)' concept. The present study mainly discussed long-lived fission products (LLFPs) burning capability and recycle scheme in the framework of metallic fuel fast reactor cycle, aiming at the goals for fuel breeding capability and confinement for TRU and radio-active FPs within the system. In present paper, burning capability for Cs135 and Zr93 is mainly discussed from neutronic and chemical view points, assuming metallic fuel cycle system. The recent experimental results indicate that Cs can be separable along with the pyroprocess for metal fuel recycle system, as previously designed for a candidate fuel cycle system. Combining neutron spectrum-shift for target sub-assemblies and isotope separation using tunable laser, LLFP burning capability is enhanced. This result indicates that major LLFPs can be treated in the additional recycle schemes to avoid LLFP accumulation along with energy production. In total, the proposed fuel cycle is an candidate for realizing SCNES concept. (author)

  5. Simplified DFT methods for consistent structures and energies of large systems

    Science.gov (United States)

    Caldeweyher, Eike; Gerit Brandenburg, Jan

    2018-05-01

    Kohn–Sham density functional theory (DFT) is routinely used for the fast electronic structure computation of large systems and will most likely continue to be the method of choice for the generation of reliable geometries in the foreseeable future. Here, we present a hierarchy of simplified DFT methods designed for consistent structures and non-covalent interactions of large systems with particular focus on molecular crystals. The covered methods are a minimal basis set Hartree–Fock (HF-3c), a small basis set screened exchange hybrid functional (HSE-3c), and a generalized gradient approximated functional evaluated in a medium-sized basis set (B97-3c), all augmented with semi-classical correction potentials. We give an overview on the methods design, a comprehensive evaluation on established benchmark sets for geometries and lattice energies of molecular crystals, and highlight some realistic applications on large organic crystals with several hundreds of atoms in the primitive unit cell.

  6. Consistency from the perspective of an experimental systems approach to the sciences and their epistemic objects

    Directory of Open Access Journals (Sweden)

    Hans-Jörg Rheinberger

    2011-06-01

    Full Text Available It is generally accepted that the development of the modern sciences is rooted in experiment. Yet for a long time, experimentation did not occupy a prominent role, neither in philosophy nor in history of science. With the 'practical turn' in studying the sciences and their history, this has begun to change. This paper is concerned with systems and cultures of experimentation and the consistencies that are generated within such systems and cultures. The first part of the paper exposes the forms of historical and structural coherence that characterize the experimental exploration of epistemic objects. In the second part, a particular experimental culture in the life sciences is briefly described as an example. A survey will be given of what it means and what it takes to analyze biological functions in the test tube.

  7. Building a polysaccharide hydrogel capsule delivery system for control release of ibuprofen.

    Science.gov (United States)

    Chen, Zhi; Wang, Ting; Yan, Qing

    2018-02-01

    Development of a delivery system which can effectively carry hydrophobic drugs and have pH response is becoming necessary. Here we demonstrate that through preparation of β-cyclodextrin polymer (β-CDP), a hydrophobic drug molecule of ibuprofen (IBU) was incorporated into our prepared β-CDP inner cavities, aiming to improve the poor water solubility of IBU. A core-shell capsule structure has been designed for achieving the drug pH targeted and sustained release. This delivery system was built with polysaccharide polymer of Sodium alginate (SA), sodium carboxymethylcellulose (CMC) and hydroxyethyl cellulose (HEC) by physical cross-linking. The drug pH-response control release is this hydrogel system's chief merit, which has potential value for synthesizing enteric capsule. Besides, due to our simple preparing strategy, optimal conditions can be readily determined and the synthesis process can be accurately controlled, leading to consistent and reproducible hydrogel capsules. In addition, phase-solubility method was used to investigate the solubilization effect of IBU by β-CDP. SEM was used to prove the forming of core and shell structure. FT-IR and 1 H-NMR were also used to perform structural characteristics. By the technique of UV determination, the pH targeted and sustained release study were also performed. The results have proved that our prepared polysaccharide hydrogel capsule delivery system has potential applications as oral drugs delivery in the field of biomedical materials.

  8. LABCORE post release 1.0 development system project management plan

    International Nuclear Information System (INIS)

    Rich, H.S.

    1994-01-01

    The LABCORE post release 1.0 development system project management plan (SPMP) is the primary planning document governing the development of specific enhancements to the LABCORE project. The mission of the Westinghouse Hanford Company (WHC) laboratories is changing from supporting the 200 Area chemical processing plants for process control, waste management, and effluent monitoring to supporting environmental restoration and regulatory compliance commitments. The LABCORE program was implemented as the key element for meeting the commitments by upgrading the laboratories through the implementation of an Automated Data Processing improvement program in January 1994. Scope for LABCORE release 1.0 consisted of hardware and software implementation required to support a minimum number of analyses (Single-Shell Tank [SST] analysis at 222S Laboratory and Performance Evaluation samples at the Waste Sampling Characterization Facility laboratory) using manual entry of data, and to support routine laboratory functions, common to all laboratories. LABCORE post release 1.0 enhancements will expand the functionality presented to the laboratory. Post release 1.0 enhancements will also address the integration of a database for Analytical Services Program Integration, budgeting, and scheduling offices into LABCORE

  9. Consistent Probabilistic Description of the Neutral Kaon System: Novel Observable Effects

    CERN Document Server

    Bernabeu, J.; Villanueva-Perez, P.

    2013-01-01

    The neutral Kaon system has both CP violation in the mass matrix and a non-vanishing lifetime difference in the width matrix. This leads to an effective Hamiltonian which is not a normal operator, with incompatible (non-commuting) masses and widths. In the Weisskopf-Wigner Approach (WWA), by diagonalizing the entire Hamiltonian, the unphysical non-orthogonal "stationary" states $K_{L,S}$ are obtained. These states have complex eigenvalues whose real (imaginary) part does not coincide with the eigenvalues of the mass (width) matrix. In this work we describe the system as an open Lindblad-type quantum mechanical system due to Kaon decays. This approach, in terms of density matrices for initial and final states, provides a consistent probabilistic description, avoiding the standard problems because the width matrix becomes a composite operator not included in the Hamiltonian. We consider the dominant-decay channel to two pions, so that one of the Kaon states with definite lifetime becomes stable. This new approa...

  10. Neutron excess generation by fusion neutron source for self-consistency of nuclear energy system

    International Nuclear Information System (INIS)

    Saito, Masaki; Artisyuk, V.; Chmelev, A.

    1999-01-01

    The present day fission energy technology faces with the problem of transmutation of dangerous radionuclides that requires neutron excess generation. Nuclear energy system based on fission reactors needs fuel breeding and, therefore, suffers from lack of neutron excess to apply large-scale transmutation option including elimination of fission products. Fusion neutron source (FNS) was proposed to improve neutron balance in the nuclear energy system. Energy associated with the performance of FNS should be small enough to keep the position of neutron excess generator, thus, leaving the role of dominant energy producers to fission reactors. The present paper deals with development of general methodology to estimate the effect of neutron excess generation by FNS on the performance of nuclear energy system as a whole. Multiplication of fusion neutrons in both non-fissionable and fissionable multipliers was considered. Based on the present methodology it was concluded that neutron self-consistency with respect to fuel breeding and transmutation of fission products can be attained with small fraction of energy associated with innovated fusion facilities. (author)

  11. TECHNICAL BASIS DOCUMENT FOR VENTILATION SYSTEM FILTRATION FAILURE LEADING TO AN UNFILTERED RELEASE

    Energy Technology Data Exchange (ETDEWEB)

    KOZLOWSKI, S.D.

    2005-01-06

    This document analyzed three scenarios involving failures of HEPA filtration systems leading to releases from liquid waste tanks. The scenarios are failure due to high temperature (fire), overpressure (filter blowout), and unfiltered release due to filter failure, improper installation. etc.

  12. Self-consistent study of space-charge-dominated beams in a misaligned transport system

    International Nuclear Information System (INIS)

    Sing Babu, P.; Goswami, A.; Pandit, V.S.

    2013-01-01

    A self-consistent particle-in-cell (PIC) simulation method is developed to investigate the dynamics of space-charge-dominated beams through a misaligned solenoid based transport system. Evolution of beam centroid, beam envelope and emittance is studied as a function of misalignment parameters for various types of beam distributions. Simulation results performed up to 40 mA of proton beam indicate that centroid oscillations induced by the displacement and rotational misalignments of solenoids do not depend of the beam distribution. It is shown that the beam envelope around the centroid is independent of the centroid motion for small centroid oscillation. In addition, we have estimated the loss of beam during the transport caused by the misalignment for various beam distributions

  13. Genetic Algorithm-Based Model Order Reduction of Aeroservoelastic Systems with Consistant States

    Science.gov (United States)

    Zhu, Jin; Wang, Yi; Pant, Kapil; Suh, Peter M.; Brenner, Martin J.

    2017-01-01

    This paper presents a model order reduction framework to construct linear parameter-varying reduced-order models of flexible aircraft for aeroservoelasticity analysis and control synthesis in broad two-dimensional flight parameter space. Genetic algorithms are used to automatically determine physical states for reduction and to generate reduced-order models at grid points within parameter space while minimizing the trial-and-error process. In addition, balanced truncation for unstable systems is used in conjunction with the congruence transformation technique to achieve locally optimal realization and weak fulfillment of state consistency across the entire parameter space. Therefore, aeroservoelasticity reduced-order models at any flight condition can be obtained simply through model interpolation. The methodology is applied to the pitch-plant model of the X-56A Multi-Use Technology Testbed currently being tested at NASA Armstrong Flight Research Center for flutter suppression and gust load alleviation. The present studies indicate that the reduced-order model with more than 12× reduction in the number of states relative to the original model is able to accurately predict system response among all input-output channels. The genetic-algorithm-guided approach exceeds manual and empirical state selection in terms of efficiency and accuracy. The interpolated aeroservoelasticity reduced order models exhibit smooth pole transition and continuously varying gains along a set of prescribed flight conditions, which verifies consistent state representation obtained by congruence transformation. The present model order reduction framework can be used by control engineers for robust aeroservoelasticity controller synthesis and novel vehicle design.

  14. Integrated environmental modeling system for noble gas releases at the Savannah River Plant

    International Nuclear Information System (INIS)

    Cooper, R.E.

    1973-01-01

    The Savannah River Plant (SRP) is a large nuclear complex engaged in varied activities and is the AEC's major site for the production of weapons material. As a result of these activities, there are continuous and intermittent releases of radioactive gases to the atmosphere. Of these releases, the noble gases constitute about 11 percent of the total man-rem exposure to the population out to a distance of 100 km. Although SRP has an extensive radiological monitoring program, an environmental modeling system is necessary for adequately estimating effects on the environment. The integrated environmental modeling system in use at SRP consists of a series of computer programs that generate and use a library of environmental effects data as a function of azimuth and distance. Annual average atmospheric dispersion and azimuthal distribution of material assumed to be released as unit sources is estimated from a 2-year meteorological data base--assuming an arbitrary point of origin. The basic library of data consists of: ground-level concentrations according to isotope, and whole body gamma dose calculations that account for the total spatial distribution at discrete energy levels. These data are normalized to tritium measurements, and are subsequently used to generate similar library data that pertain to specific source locations, but always with respect to the same population grid. Thus, the total additive effects from all source points, both on- and off-site, can be estimated. The final program uses the library data to estimate population exposures for specified releases and source points for the nuclides of interest (including noble gases). Multiple source points are considered within a single pass to obtain the integrated effects from all sources

  15. Chitosan nanoparticles as a modified diclofenac drug release system

    Science.gov (United States)

    Duarte Junior, Anivaldo Pereira; Tavares, Eraldo José Madureira; Alves, Taís Vanessa Gabbay; de Moura, Márcia Regina; da Costa, Carlos Emmerson Ferreira; Silva Júnior, José Otávio Carréra; Ribeiro Costa, Roseane Maria

    2017-08-01

    This study evaluated a modified nanostructured release system employing diclofenac as a drug model. Biodegradable chitosan nanoparticles were prepared with chitosan concentrations between 0.5 and 0.8% ( w/ v) by template polymerization method using methacrylic acid in aqueous solution. Chitosan-poly(methacrylic acid) (CS-PMAA) nanoparticles showed uniform size around 50-100 nm, homogeneous morphology, and spherical shape. Raw material and chitosan nanoparticles were characterized by thermal analysis, Fourier transform infrared spectroscopy (FT-IR), and transmission electron microscopy (TEM), confirming the interaction between chitosan and methacrylic acid during nanoparticles preparation. Diclofenac sorption on the chitosan nanoparticles surface was achieved by incubation in water/ethanol (1:1) drug solution in concentrations of 0.5 and 0.8 mg/mL. The diclofenac amount sorbed per gram of CS-PMAA nanoparticles, when in a 0.5 mg/mL sodium diclofenac solution, was as follows: 12.93, 15, 20.87, and 29.63 mg/g for CS-PMAA nanoparticles 0.5, 0.6, 0.7, and 0.8% ( w/ v), respectively. When a 0.8 mg/mL sodium diclofenac solution was used, higher sorption efficiencies were obtained: For CS-PMAA nanoparticles with chitosan concentrations of 0.5, 0.6, 0.7, and 0.8% ( w/ v), the sorption efficiencies were 33.39, 49.58, 55.23, and 67.2 mg/g, respectively. Diclofenac sorption kinetics followed a second-order kinetics. Drug release from nanoparticles occurred in a period of up to 48 h and obeyed Korsmeyer-Peppas model, which was characterized mainly by Fickian diffusion transport. [Figure not available: see fulltext.

  16. Wire position system to consistently measure and record the location change of girders following ground changes

    Science.gov (United States)

    Choi, H. J.; Lee, S. B.; Lee, H. G.; Y Back, S.; Kim, S. H.; Kang, H. S.

    2017-07-01

    Several parts that comprise the large scientific device should be installed and operated at the accurate three-dimensional location coordinates (X, Y, and Z) where they should be subjected to survey and alignment. The location of the aligned parts should not be changed in order to ensure that the electron beam parameters (Energy 10 GeV, Charge 200 pC, and Bunch Length 60 fs, Emittance X/Y 0.481 μm/0.256 μm) of PAL-XFEL (X-ray Free Electron Laser of the Pohang Accelerator Laboratory) remain stable and can be operated without any problems. As time goes by, however, the ground goes through uplift and subsidence, which consequently deforms building floors. The deformation of the ground and buildings changes the location of several devices including magnets and RF accelerator tubes, which eventually leads to alignment errors (∆X, ∆Y, and ∆Z). Once alignment errors occur with regard to these parts, the electron beam deviates from its course and beam parameters change accordingly. PAL-XFEL has installed the Hydrostatic Leveling System (HLS) to measure and record the vertical change of buildings and ground consistently and systematically and the Wire Position System (WPS) to measure the two dimensional changes of girders. This paper is designed to introduce the operating principle and design concept of WPS and discuss the current situation regarding installation and operation.

  17. Multi-component Self-Consistent Nuclear Energy System: On proliferation resistance aspect

    International Nuclear Information System (INIS)

    Shmelev, A.; Saito, M; Artisyuk, V.

    2000-01-01

    Self-Consistent Nuclear Energy System (SCNES) that simultaneously meets four requirements: energy production, fuel production, burning of radionuclides and safety is targeted at harmonization of nuclear energy technology with human environment. The main bulk of SCNES studies focus on a potential of fast reactor (FR) in generating neutron excess to keep suitable neutron balance. Proliferation resistance was implicitly anticipated in a fuel cycle with co-processing of Pu, minor actinides (MA) and some relatively short-lived fission products (FP). In a contrast to such a mono-component system, the present paper advertises advantage of incorporating accelerator and fusion driven neutron sources which could drastically improve characteristics of nuclear waste incineration. What important is that they could help in creating advanced Np and Pa containing fuels with double protection against uncontrolled proliferation. The first level of protection deals with possibility to approach long life core (LLC) in fission reactors. Extending the core life-time to reactor-time is beneficial from the proliferation resistance viewpoint since LLC would not necessarily require fuel management at energy producing site, with potential advantage of being moved to vendor site for spent fuel refabrication. Second level is provided by the presence of substantial amounts of 238 Pu and 232 U in these fuels that makes fissile nuclides in them isotopically protected. All this reveals an important advantage of a multi-component SCNES that could draw in developing countries without elaborated technological infrastructure. (author)

  18. [Consistency and Reliability of MDK Expertise Examining the Encoding in the German DRG System].

    Science.gov (United States)

    Gaertner, T; Lehr, F; Blum, B; van Essen, J

    2015-09-01

    Hospital inpatient stays are reimbursed on the basis of German diagnosis-related groups (G-DRG). The G-DRG classification system is based on complex coding guidelines. The Medical Review Board of the Statutory Health Insurance Funds (MDK) examines the encoding by hospitals and delivers individual expertises on behalf of the German statutory health insurance companies in cases in which irregularities are suspected. A study was conducted on the inter-rater reliability of the MDK expertises regarding the scope of the assessment. A representative sample of 212 MDK expertises was taken from a selected pool of 1 392 MDK expertises in May 2013. This representative sample underwent a double-examination by 2 independent MDK experts using a special software based on the 3MTM G-DRG Grouper 2013 of 3M Medica, Germany. The following items encoded by the hospitals were examined: DRG, principal diagnosis, secondary diagnoses, procedures and additional payments. It was analysed whether the results of MDK expertises were consistent, reliable and correct. 202 expertises were eligible for evaluation, containing a total of 254 questions regarding one or more of the 5 items encoded by hospitals. The double-examination by 2 independent MDK experts showed matching results in 187 questions (73.6%) meaning they had been examined consistently and correctly. 59 questions (23.2%) did not show matching results, nevertheless they had been examined correctly regarding the scope of the assessment. None of the principal diagnoses was significantly affected by inconsistent or wrong judgment. A representative sample of MDK expertises examining the DRG encoding by hospitals showed a very high percentage of correct examination by the MDK experts. Identical MDK expertises cannot be achieved in all cases due to the scope of the assessment. Further improvement and simplification of codes and coding guidelines are required to reduce the scope of assessment with regard to correct DRG encoding and its

  19. Dental students consistency in applying the ICDAS system within paediatric dentistry.

    Science.gov (United States)

    Foley, J I

    2012-12-01

    To examine dental students' consistency in utilising the International Caries Detection and Assessment System (ICDAS) one and three months after training. A prospective study. All clinical dental students (Year Two: BDS2; Year Three: BDS3; Year Four: BDS4) as part of their education in Paediatric Dentistry at Aberdeen Dental School (n = 56) received baseline training by two "gold-standard" examiners and were advised to complete the 90-minute ICDAS e-learning program. Study One: One month later, the occlusal surface of 40 extracted primary and permanent molar teeth were examined and assigned both a caries (0-6 scale) and restorative code (0-9 scale). Study Two: The same teeth were examined three months later. Kappa statistics were used to determine inter- and intra-examiner reliability at baseline and after three months. In total, 31 students (BDS2: n = 9; BDS3: n = 8; BDS4: n = 14) completed both examinations. The inter-examiner reliability kappa scores for restoration codes for Study One and Study Two were: BDS2: 0.47 and 0.38; BDS3: 0.61 and 0.52 and BDS4: 0.56 and 0.52. The caries scores for the two studies were: BDS2: 0.31 and 0.20; BDS3: 0.45 and 0.32 and BDS4: 0.35 and 0.34. The intra-examiner reliability range for restoration codes were: BDS2: 0.20 to 0.55; BDS3: 0.34 to 0.72 and BDS4: 0.28 to 0.80. The intra-examiner reliability range for caries codes were: BDS2: 0.35 to 0.62; BDS3: 0.22 to 0.53 and BDS4: 0.22 to 0.65. The consistency of ICDAS codes varied between students and also, between year groups. In general, consistency was greater for restoration codes.

  20. Self-consistent spectral function for non-degenerate Coulomb systems and analytic scaling behaviour

    International Nuclear Information System (INIS)

    Fortmann, Carsten

    2008-01-01

    Novel results for the self-consistent single-particle spectral function and self-energy are presented for non-degenerate one-component Coulomb systems at various densities and temperatures. The GW (0) -method for the dynamical self-energy is used to include many-particle correlations beyond the quasi-particle approximation. The self-energy is analysed over a broad range of densities and temperatures (n = 10 17 cm -3 -10 27 cm -3 , T = 10 2 eV/k B -10 4 eV/k B ). The spectral function shows a systematic behaviour, which is determined by collective plasma modes at small wavenumbers and converges towards a quasi-particle resonance at higher wavenumbers. In the low density limit, the numerical results comply with an analytic scaling law that is presented for the first time. It predicts a power-law behaviour of the imaginary part of the self-energy, ImΣ ∼ -n 1/4 . This resolves a long time problem of the quasi-particle approximation which yields a finite self-energy at vanishing density

  1. Chaos in a four-dimensional system consisting of fundamental lag elements and the relation to the system eigenvalues

    International Nuclear Information System (INIS)

    Kita, Toshihiro

    2005-01-01

    A simple system consisting of a second-order lag element (a damped linear pendulum) and two first-order lag elements with piecewise-linear static feedback that has been derived from a power system model is presented. It exhibits chaotic behavior for a wide range of parameter values. The analysis of the bifurcations and the chaotic behavior are presented with qualitative estimation of the parameter values for which the chaotic behavior is observed. Several characteristics like scalability of the attractor and globality of the attractor-basin are also discussed

  2. Alginate-Chitosan Particulate System for Sustained Release of ...

    African Journals Online (AJOL)

    Erah

    1School of Pharmacy and Health Sciences, International Medical University, Kuala Lumpur, Malaysia, 2Division of ... Both calcium alginate beads and the beads treated with chitosan failed to release ..... also found to fit the classical power law.

  3. Hierarchical fault diagnosis for discrete-event systems under local consistency

    NARCIS (Netherlands)

    Su, Rong; Wonham, W.M.

    2006-01-01

    In previous work the authors proposed a distributed diagnosis approach consisting of two phases—preliminary diagnosis in each local diagnoser and inter-diagnoser communication. The objective of communication is to achieve either global or local consistency among local diagnoses, where global

  4. Assessment of the Degree of Consistency of the System of Fuzzy Rules

    Directory of Open Access Journals (Sweden)

    Pospelova Lyudmila Yakovlevna

    2013-12-01

    Full Text Available The article analyses recent achievements and publications and shows that difficulties of explaining the nature of fuzziness and equivocation arise in socio-economic models that use the traditional paradigm of classical rationalism (computational, agent and econometric models. The accumulated collective experience of development of optimal models confirms prospectiveness of application of the fuzzy set approach in modelling the society. The article justifies the necessity of study of the nature of inconsistency in fuzzy knowledge bases both on the generalised ontology level and on pragmatic functional level of the logical inference. The article offers the method of search for logical and conceptual contradictions in the form of a combination of the abduction and modus ponens. It discusses the key issue of the proposed method: what properties should have the membership function of the secondary fuzzy set, which describes in fuzzy inference models such a resulting state of the object of management, which combines empirically incompatible properties with high probability. The degree of membership of the object of management in several incompatible classes with respect to the fuzzy output variable is the degree of fuzziness of the “Intersection of all results of the fuzzy inference of the set, applied at some input of rules, is an empty set” statement. The article describes an algorithm of assessment of the degree of consistency. It provides an example of the step-by-step detection of contradictions in statistical fuzzy knowledge bases at the pragmatic functional level of the logical output. The obtained results of testing in the form of sets of incompatible facts, output chains, sets of non-crossing intervals and computed degrees of inconsistency allow experts timely elimination of inadmissible contradictions and, at the same time, increase of quality of recommendations and assessment of fuzzy expert systems.

  5. AEROS: a real-time emergency response system for atmospheric releases of toxic material

    International Nuclear Information System (INIS)

    Nasstrom, J.S.; Greenly, G.D.

    1986-01-01

    The Atmospheric Release Advisory Capability (ARAC) at the Lawrence Livermore National Laboratory has developed a sophisticated computer-based real-time emergency response system for radiotoxic releases into the atmosphere. The ARAC Emergency Response Operating System (AEROS) has a centralized computer facility linked to remote site computers, meteorological towers, and meteorological data sources. The system supports certain fixed sites, but has the ability to respond to accidents at arbitrary locations. Product quality and response time are optimized by using complex three-dimensional dispersion models; extensive on-line data bases; automated data processing; and an efficient user interface, employing graphical computer displays and computer-displayed forms. Upon notification, the system automatically initiates a response to an emergency and proceeds through preliminary calculations, automatically processing accident information, meteorological data, and model parameters. The model calculations incorporate mass-consistent three-dimensional wind fields, terrain effects, and particle-in-cell diffusion. Model products are color images of dose or deposition contours overlaid on a base map

  6. The olfactory gonadotropin-releasing hormone immunoreactive system in mouse.

    Science.gov (United States)

    Jennes, L

    1986-10-29

    The olfactory gonadotropin-releasing hormone (GnRH) system in mice was studied with immunofluorescence in combination with lesions of the olfactory bulb and retrograde transport of horseradish peroxidase (HRP) which was administered intravascularly, intranasally or into the subarachnoid space. GnRH-positive neurons were located in the two major branches forming the septal roots of the nervus terminalis, in the ganglion terminale, within the fascicles of the nervus terminalis throughout its extent, in a conspicuous band which connects the ventral neck of the caudal olfactory bulb with the accessory olfactory bulb and in the nasal mucosa. GnRH-positive fibers were seen in all areas in which neurons were found, i.e. in the rostral septum, the ganglion and nervus terminalis and in the nasal subepithelium. In addition, a broad bundle of fibers was observed to surround the entire caudal olfactory bulb, connecting the rostral sulcus rhinalis with the ventrocaudal olfactory bulb. Fibers were seen in close association with the main and accessory olfactory bulb, with the fila olfactoria and with the nasal mucosa. Throughout the olfactory bulb and the nasal epithelium, an association of GnRH fibers with blood vessels was apparent. Intravascular and intranasal injection of HRP resulted in labeling of certain GnRH neurons in the septal roots of the nervus terminalis, the ganglion terminale, the nervus terminalis, the caudal ventrodorsal connection and in the accessory olfactory bulb. After placement of HRP into the subarachnoid space dorsal to the accessory olfactory bulb, about 50% of the GnRH neurons in the accessory olfactory bulb and in the ventrodorsal connection were labeled with HRP. Also, a few GnRH neurons in the rostral septum, the ganglion terminale and in the fascicles of the nervus terminalis had taken up the enzyme. Lesions of the nervus terminalis caudal to the ganglion terminale resulted in sprouting of GnRH fibers at both sites of the knife cut. Lesions rostral

  7. Release of metal ions from fixed orthodontic appliance: an in vitro study in continuous flow system.

    Science.gov (United States)

    Mikulewicz, Marcin; Chojnacka, Katarzyna; Wołowiec, Paulina

    2014-01-01

    To evaluate the release of metal ions from fixed orthodontic appliances. A new system for in vitro testing of dental materials was constructed and consisted of a thermostatic glass reactor that enabled immersion of the studied material. Experimental conditions reflected the human oral cavity, with a temperature of 37°C and a saliva flow rate of 0.5mL/min. The simulated fixed orthodontic appliance made of stainless steel was evaluated. Sampling was performed at several time points during the 28-day study, and the metal ion concentration was determined by inductively coupled plasma optical emission spectrometry. The total mass of released metal ions from the appliance during 4 weeks of the experiment was as follows nickel 18.7 μg, chromium 5.47 μg, copper 31.3 μg. The estimated doses of nickel, chromium, and copper determined by extrapolation of experimental data released during the treatment period were far below the toxic dose to humans. This shows that orthodontic treatment might not be a significant source of exposure to these metal ions.

  8. Elastic constants of the hard disc system in the self-consistent free volume approximation

    International Nuclear Information System (INIS)

    Wojciechowski, K.W.

    1990-09-01

    Elastic moduli of the two dimensional hard disc crystal are determined exactly within the Kirkwood self-consistent free volume approximation and compared with the Monte Carlo simulation results. (author). 22 refs, 1 fig., 1 tab

  9. Adjoint-consistent formulations of slip models for coupled electroosmotic flow systems

    KAUST Repository

    Garg, Vikram V; Prudhomme, Serge; van der Zee, Kris G; Carey, Graham F

    2014-01-01

    Models based on the Helmholtz `slip' approximation are often used for the simulation of electroosmotic flows. The objectives of this paper are to construct adjoint-consistent formulations of such models, and to develop adjoint

  10. A Decision Support System to Choose Optimal Release Cycle Length in Incremental Software Development Environments

    OpenAIRE

    Suman, Avnish Chandra; Mishra, Saraswati; Anand, Abhinav

    2016-01-01

    In the last few years it has been seen that many software vendors have started delivering projects incrementally with very short release cycles. Best examples of success of this approach has been Ubuntu Operating system that has a 6 months release cycle and popular web browsers such as Google Chrome, Opera, Mozilla Firefox. However there is very little knowledge available to the project managers to validate the chosen release cycle length. We propose a decision support system that...

  11. Adjoint-consistent formulations of slip models for coupled electroosmotic flow systems

    KAUST Repository

    Garg, Vikram V

    2014-09-27

    Background Models based on the Helmholtz `slip\\' approximation are often used for the simulation of electroosmotic flows. The objectives of this paper are to construct adjoint-consistent formulations of such models, and to develop adjoint-based numerical tools for adaptive mesh refinement and parameter sensitivity analysis. Methods We show that the direct formulation of the `slip\\' model is adjoint inconsistent, and leads to an ill-posed adjoint problem. We propose a modified formulation of the coupled `slip\\' model, which is shown to be well-posed, and therefore automatically adjoint-consistent. Results Numerical examples are presented to illustrate the computation and use of the adjoint solution in two-dimensional microfluidics problems. Conclusions An adjoint-consistent formulation for Helmholtz `slip\\' models of electroosmotic flows has been proposed. This formulation provides adjoint solutions that can be reliably used for mesh refinement and sensitivity analysis.

  12. Formulation of Dipyridamole Sustained Release Tablet Using Floating System

    Directory of Open Access Journals (Sweden)

    Lenny Mauilida Valentina

    2011-06-01

    Full Text Available Dipyridamole is a drug for prevention of postoperative thromboembolic complication of heart valve replacement and long term therapy of angina pectoris will be well absorbed in stomach. To maintain therapeutic plasma concentration in long time and to increase bioavalaibility is needed a sustained release dosage form having the long residence time in the stomach. The objective of this research was to make floating sustained release tablet of dipyridamole conforming to the requirement that was set up by dipyridamol therapeutic concentration. Tablets were made by wet granulation method using aquadest as a liquid binder, HPMC K4M, Ac-di-sol, Avicel PH 102, talk, and Mg stearat. Dissolution assay was carried out using type 2 release tester at rotation speed of 50 rpm in medium 900 mL HCl 0.1 N at 37 ± 0.5 °C for 8 hours. The formulation containing of 50 mg dipirydamole, HPMC K4M (30%, Ac-di-sol (20%, Avicel PH 102 (37%, talk (2%, and Mg stearat (1% released 59.61 ± 6.73% and 89.34 ± 5.87% of dipyridamole respectively after 4 and 8 hours that conformed to the requirement.

  13. Global and local consistencies in distributed fault diagnosis for discrete-event systems

    NARCIS (Netherlands)

    Su, R.; Wonham, W.M.

    2005-01-01

    In this paper, we present a unified framework for distributed diagnosis. We first introduce the concepts of global and local consistency in terms of supremal global and local supports, then present two distributed diagnosis problems based on them. After that, we provide algorithms to achieve

  14. Self-consistency condition and high-density virial theorem in relativistic many-particle systems

    International Nuclear Information System (INIS)

    Kalman, G.; Canuto, V.; Datta, B.

    1976-01-01

    In order for the thermodynamic and kinetic definitions of the chemical potential and the pressure to lead to identical results a nontrivial self-consistency criterion has to be satisfied. This, in turn, leads to a virial-like theorem in the high-density limit

  15. A discussion of coupling and resonance effects for integrated systems consisting of subsystems

    International Nuclear Information System (INIS)

    Lin, C.W.; Liu, T.H.

    1975-01-01

    Three representative cases are studied to evaluate the interaction effect and to establish the need to include both stiffness and mass of the interacting systems in the system model. The first case is a supported system supported by a two-degrees-of-freedom supporting system. The second case represents two single degree of freedom systems, each supported by itself, but interconnected by a spring. The third case is a single degree of freedom system supported by another single degree of freedom supporting system. In each of the three case studied, the interaction effect is first measured by the difference in their natural frequencies for both the coupled system and the uncoupled systems. Although natural frequencies are important to the dynamic analysis of a system, the ultimate decision of whether the mathematical model is realistic depends on the result of the system response it predicts. With this in mind, case three is then studied with a white noise input. It is found that the root mean square response of both the supporting systems are substantially lower when coupled than when the systems are analyzed separately. Based on the results of this study, guidelines are provided for the subdivision into subsystems. (orig./HP) [de

  16. Mechanistic modelling of drug release from polymer-coated and swelling and dissolving polymer matrix systems.

    Science.gov (United States)

    Kaunisto, Erik; Marucci, Mariagrazia; Borgquist, Per; Axelsson, Anders

    2011-10-10

    The time required for the design of a new delivery device can be sensibly reduced if the release mechanism is understood and an appropriate mathematical model is used to characterize the system. Once all the model parameters are obtained, in silico experiments can be performed, to provide estimates of the release from devices with different geometries and compositions. In this review coated and matrix systems are considered. For coated formulations, models describing the diffusional drug release, the osmotic pumping drug release, and the lag phase of pellets undergoing cracking in the coating due to the build-up of a hydrostatic pressure are reviewed. For matrix systems, models describing pure polymer dissolution, diffusion in the polymer and drug release from swelling and eroding polymer matrix formulations are reviewed. Importantly, the experiments used to characterize the processes occurring during the release and to validate the models are presented and discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. A novel osmotic pump-based controlled delivery system consisting of pH-modulated solid dispersion for poorly soluble drug flurbiprofen: in vitro and in vivo evaluation.

    Science.gov (United States)

    Li, Shujuan; Wang, Xiaoyu; Wang, Yingying; Zhao, Qianqian; Zhang, Lina; Yang, Xinggang; Liu, Dandan; Pan, Weisan

    2015-01-01

    In this study, a novel controlled release osmotic pump capsule consisting of pH-modulated solid dispersion for poorly soluble drug flurbiprofen (FP) was developed to improve the solubility and oral bioavailability of FP and to minimize the fluctuation of plasma concentration. The pH-modulated solid dispersion containing FP, Kollidon® 12 PF and Na2CO3 at a weight ratio of 1/4.5/0.02 was prepared using the solvent evaporation method. The osmotic pump capsule was assembled by semi-permeable capsule shell of cellulose acetate (CA) prepared by the perfusion method. Then, the solid dispersion, penetration enhancer, and suspending agents were tableted and filled into the capsule. Central composite design-response surface methodology was used to evaluate the influence of factors on the responses. A second-order polynomial model and a multiple linear model were fitted to correlation coefficient of drug release profile and ultimate cumulative release in 12 h, respectively. The actual response values were in good accordance with the predicted ones. The optimized formulation showed a complete drug delivery and zero-order release rate. Beagle dogs were used to be conducted in the pharmacokinetic study. The in vivo study indicated that the relative bioavailability of the novel osmotic pump system was 133.99% compared with the commercial preparation. The novel controlled delivery system with combination of pH-modulated solid dispersion and osmotic pump system is not only a promising strategy to improve the solubility and oral bioavailability of poorly soluble ionizable drugs but also an effective way to reduce dosing frequency and minimize the plasma fluctuation.

  18. Self-consistent quasi-particle RPA for the description of superfluid Fermi systems

    CERN Document Server

    Rahbi, A; Chanfray, G; Schuck, P

    2002-01-01

    Self-Consistent Quasi-Particle RPA (SCQRPA) is for the first time applied to a more level pairing case. Various filling situation and values for the coupling constant are considered. Very encouraging results in comparison with the exact solution of the model are obtaining. The nature of the low lying mode in SCQRPA is identified. The strong reduction of the number fluctuation in SCQRPA vs BCS is pointed out. The transition from superfluidity to the normal fluid case is carefully investigated.

  19. STUDY OF TRANSIENT AND STATIONARY OPERATION MODES OF SYNCHRONOUS SYSTEM CONSISTING IN TWO MACHINES

    Directory of Open Access Journals (Sweden)

    V. S. Safaryan

    2017-01-01

    Full Text Available The solution of the problem of reliable functioning of an electric power system (EPS in steady-state and transient regimes, prevention of EPS transition into asynchronous regime, maintenance and restoration of stability of post-emergency processes is based on formation and realization of mathematical models of an EPS processes. During the functioning of electric power system in asynchronous regime, besides the main frequencies, the currents and voltages include harmonic components, the frequencies of which are multiple of the difference of main frequencies. At the two-frequency asynchronous regime the electric power system is being made equivalent in a form of a two-machine system, functioning for a generalized load. In the article mathematical models of transient process of a two-machine system in natural form and in d–q coordinate system are presented. The mathematical model of two-machine system is considered in case of two windings of excitement at the rotors. Also, in the article varieties of mathematical models of EPS transient regimes (trivial, simple, complete are presented. Transient process of a synchronous two-machine system is described by the complete model. The quality of transient processes of a synchronous machine depends on the number of rotor excitation windings. When there are two excitation windings on the rotor (dual system of excitation, the mathematical model of electromagnetic transient processes of a synchronous machine is represented in a complex form, i.e. in coordinate system d, q, the current of rotor being represented by a generalized vector. In asynchronous operation of a synchronous two-machine system with two excitation windings on the rotor the current and voltage systems include only harmonics of two frequencies. The mathematical model of synchronous steady-state process of a two-machine system is also provided, and the steady-state regimes with different structures of initial information are considered.

  20. Controlled release for crop and wood protection: Recent progress toward sustainable and safe nanostructured biocidal systems.

    Science.gov (United States)

    Mattos, Bruno D; Tardy, Blaise L; Magalhães, Washington L E; Rojas, Orlando J

    2017-09-28

    We review biocide delivery systems (BDS), which are designed to deter or control harmful organisms that damage agricultural crops, forests and forest products. This is a timely topic, given the growing socio-economical concerns that have motivated major developments in sustainable BDS. Associated designs aim at improving or replacing traditional systems, which often consist of biocides with extreme behavior as far as their solubility in water. This includes those that compromise or pollute soil and water (highly soluble or volatile biocides) or those that present low bioavailability (poorly soluble biocides). Major breakthroughs are sought to mitigate or eliminate consequential environmental and health impacts in agriculture and silviculture. Here, we consider the most important BDS vehicles or carriers, their synthesis, the environmental impact of their constituents and interactions with the active components together with the factors that affect their rates of release such as environmental factors and interaction of BDS with the crops or forest products. We put in perspective the state-of-the-art nanostructured carriers for controlled release, which need to address many of the challenges that exist in the application of BDS. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Consistency Analysis and Data Consultation of Gas System of Gas-Electricity Network of Latvia

    Science.gov (United States)

    Zemite, L.; Kutjuns, A.; Bode, I.; Kunickis, M.; Zeltins, N.

    2018-02-01

    In the present research, the main critical points of gas transmission and storage system of Latvia have been determined to ensure secure and reliable gas supply among the Baltic States to fulfil the core objectives of the EU energy policies. Technical data of critical points of the gas transmission and storage system of Latvia have been collected and analysed with the SWOT method and solutions have been provided to increase the reliability of the regional natural gas system.

  2. Liquid crystalline systems for transdermal delivery of celecoxib: in vitro drug release and skin permeation studies.

    Science.gov (United States)

    Estracanholli, Eder André; Praça, Fabíola Silva Garcia; Cintra, Ana Beatriz; Pierre, Maria Bernadete Riemma; Lara, Marilisa Guimarães

    2014-12-01

    Liquid crystalline systems of monoolein/water could be a promising approach for the delivery of celecoxib (CXB) to the skin because these systems can sustain drug release, improve drug penetration into the skin layers and minimize side effects. This study evaluated the potential of these systems for the delivery of CXB into the skin based on in vitro drug release and skin permeation studies. The amount of CXB that permeated into and/or was retained in the skin was assayed using an HPLC method. Polarizing light microscopy studies showed that liquid crystalline systems of monoolein/water were formed in the presence of CXB, without any changes in the mesophases. The liquid crystalline systems decreased drug release when compared to control solution. Drug release was independent of the initial water content of the systems and CXB was released from cubic phase systems, irrespective of the initial water content. The systems released the CXB following zero-order release kinetics. In vitro drug permeation studies showed that cubic phase systems allowed drug permeation and retention in the skin layers. Cubic phase systems of monoolein/water may be promising vehicles for the delivery of CXB in/through the skin because it improved CXB skin permeation compared with the control solution.

  3. Process-aware information system development for the healthcare domain : consistency, reliability and effectiveness

    NARCIS (Netherlands)

    Mans, R.S.; Aalst, van der W.M.P.; Russell, N.C.; Bakker, P.J.M.; Moleman, A.J.; Rinderle-Ma, S.; Sadiq, S.; Leymann, F.

    2010-01-01

    Optimal support for complex healthcare processes cannot be provided by a single out-of-the-box Process-Aware Information System and necessitates the construction of customized applications based on these systems. In order to allow for the seamless integration of the new technology into the existing

  4. Orthodontic forces released by low-friction versus conventional systems during alignment of apically or buccally malposed teeth.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Camporesi, Matteo; Defraia, Efisio

    2011-02-01

    The aim of the present study was to analyse the forces released by passive stainless steel self-ligating brackets (SLBs) and by a non-conventional elastomeric ligature-bracket system on conventional brackets ([slide ligatures on conventional brackets (SLCB)]) when compared with conventional elastomeric ligatures on conventional brackets (CLCB) during the alignment of apically or buccally malposed teeth in the maxillary arch. An experimental model consisting of five brackets was used to assess the forces released by the three different bracket-ligature systems with 0.012-inch super-elastic (SE) nickel-titanium (NiTi) wires in the presence of different amounts of apical or buccal canine misalignment of the canine (ranging from 1.5 to 6 mm). The forces released by each wire/bracket/ligature combination with the three different amounts of apical or buccal canine misalignment were tested 20 times. Comparisons between the different types of wire/bracket/ligature systems were carried out by means of analysis of variance on ranks with Dunnett's post hoc test (P < 0.05). No difference in the amount of force released in presence of a misalignment of 1.5 mm was recorded among the three systems. At 3 mm of apical misalignment a significantly greater amount of orthodontic force was released by SLB or SLCB when compared with CLCB, while no significant differences were found among the three systems at 3 mm of buccal canine displacement. When correction of a large amount of misalignment (6 mm) was attempted, a noticeable amount of force for alignment was still generated by the passive SLB and SLCB systems while no force was released in presence of CLCB.

  5. The effect of consistent practice of yogic breathing exercises on the human cardiorespiratory system.

    Science.gov (United States)

    McKay, Joshua A A; McCulloch, Cara L; Querido, Jordan S; Foster, Glen E; Koehle, Michael S; Sheel, A William

    2016-11-01

    The purpose of this investigation was to quantify the cardiovascular, respiratory, and cerebrovascular effects of two common yogic breathing exercises (YBE): bhastrika and chaturbhuj; and to determine the effect of their consistent practice on chemosensitivity. The first study was cross-sectional and compared experienced yogic breathers (YB) with matched controls; whereas the second was a 10-week longitudinal training study. The results support four major findings. First chaturbhuj resulted in a hypoxic stimulus in experienced YB compared to control [end-tidal oxygen tension (P ET O 2 ), YB: 77.5±5.7mmHg, Pbreath-hold: 90.8 8±12.1mmHg) compared to rest (100.1±7.4, Pbreath-hold (96.7±13.0mmHg) compared to rest (83.0±6.6mmHg, Pbreath-hold: 87.4±23.0cm/s, P<0.05; rest: 55.8±26.3cm/s). Fourth, experienced YB had lower central chemosensitivity than controls (YB: 3.4±0.4; control: 4.6±1.2L/min/mmHg; P<0.05). In conclusion, YBE significantly alter end-tidal gases, resulting in complex oscillations of cardiovascular and cerebrovascular variables, and if practiced consistently, may reduce chemosensitivity. Copyright © 2016. Published by Elsevier B.V.

  6. Construction of an integrated enzyme system consisting azoreductase and glucose 1-dehydrogenase for dye removal.

    Science.gov (United States)

    Yang, Yuyi; Wei, Buqing; Zhao, Yuhua; Wang, Jun

    2013-02-01

    Azo dyes are toxic and carcinogenic and are often present in industrial effluents. In this research, azoreductase and glucose 1-dehydrogenase were coupled for both continuous generation of the cofactor NADH and azo dye removal. The results show that 85% maximum relative activity of azoreductase in an integrated enzyme system was obtained at the conditions: 1U azoreductase:10U glucose 1-dehydrogenase, 250mM glucose, 1.0mM NAD(+) and 150μM methyl red. Sensitivity analysis of the factors in the enzyme system affecting dye removal examined by an artificial neural network model shows that the relative importance of enzyme ratio between azoreductase and glucose 1-dehydrogenase was 22%, followed by dye concentration (27%), NAD(+) concentration (23%) and glucose concentration (22%), indicating none of the variables could be ignored in the enzyme system. Batch results show that the enzyme system has application potential for dye removal. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Design of environment monitoring system to evaluate radionuclide release from subsystem on PWR nuclear power accident

    International Nuclear Information System (INIS)

    Sri Kuntjoro; Sugiyanto; Pande Made Udiyani; Jupiter Sitorus Pane

    2012-01-01

    Nuclear Power Plan (NPP) as a renewable energy source is selected as an alternative, because it has many advantages that is environmentally friendly, fuel supply which is independent of the season, and the price that can compete with other power plants. However, the existence of some public skepticism about nuclear radiation safety, the government must be convinced about the operation of nuclear power plants are safe and secure. Research on the design of environment monitoring system for evaluation of radionuclide release from the reactor subsystems and the environment due to accidents at power reactors has been done. The study was conducted by calculating the distribution of radionuclide release into the reactor subsystem and the environment and also to build the environment radiation monitoring system. Environmental monitoring system consists of a radiation counter, early warning systems, meteorological measurement systems, GPS systems and GIS. Radiation monitoring system used to record the data of radiation, meteorological measurement system used to record data of wind and speed direction, while the GPS system is used to determine position of data measurements. The data is then transmitted to a data acquisition system and then to be transmitted to the control center. Collection and transmission of data is done via SMS formatting using a modem device that is placed in the control center. The control center receives measurement data from various places. In this case the control center has a function as an SMS Gateway. This system can visualize for different measurement locations. Furthermore, radiation data and position data to be integrated with digital maps. System integration is then visualized in a personal computer. To position of measurements directly visualized on the map and also look for the data displayed on a monitor as a red or green circle colour. That colour indicated as a safe limit of radiation monitor. When the cycle colour is red, the system will

  8. Self-consistent theory of steady-state lamellar solidification in binary eutectic systems

    International Nuclear Information System (INIS)

    Nash, G.E.; Glicksman, M.E.

    1976-01-01

    The potential theoretic methods developed recently at NRL for solving the diffusion equation are applied to the free-boundary problem describing lamellar eutectic solidification. Using these techniques, the original boundary value problem is reduced to a set of coupled integro-differential equations for the shape of the solid/liquid interface and various quantities defined on the interface. The behavior of the solutions is discussed in a qualitative fashion, leading to some interesting inferences regarding the nature of the eutectic solidification process. Using the information obtained from the analysis referred to above, an approximate theory of the lamellar-rod transition is formulated. The predictions of the theory are shown to be in qualitative agreement with experimental observations of this transition. In addition, a simplified version of the general integro-differential equations is developed and is used to assess the effect of interface curvature on the interfacial solute concentrations, and to check the new theory for consistency with experiment

  9. Development of filter module for passive filtration and accident gas release confinement system for NPP

    International Nuclear Information System (INIS)

    Yelizarov, P.G.; Efanov, A.D.; Martynov, P.N.; Masalov, D.P.; Osipov, V.P.; Yagodkin, I.V.

    2005-01-01

    Full text of publication follows: One of the urgent problems of the safe NPP operation is air cleaning from radioactive aerosols and volatile iodine compounds under the accident operation conditions of NPP. A principally new passive accident gas release confinement system is used as the basis of the designs of new generation reactor power blocks under the-beyond-design-basis accident conditions with total loss of current. The basic structural component of the passive filtration system (PFS) is the filter-sorber being heated up to 300 deg. C. The filter-sorber represents a design consisting of 150 connected in parallel two-step filtering modules. The first step is intended to clean air from radioactive aerosols, the second one - to clean air from radioactive iodine and its volatile compounds. The filter-sorber is located in the upper point of the exterior protection shell. Due to natural convection, it provides confinement of r/a impurities and controlled steam-gas release from the inter-shell space into atmosphere. The basic specific design feature is the two-section design of the PFS filter module consisting of a coarse-cleaning section and a fine-cleaning section. A combination of layer-by-layer put filtering materials on the basis of glass fiber and metal fiber. The pilot PFS filter module specimen tests run in conditions modeling accident situation indicated that at a filtration rate of 0,3 cm/s the aerodynamic resistance of the module does not exceed 12 Pa, the filtration effectiveness equals 99,99 % in terms of aerosol, no less than 99,9% in terms of radioactive 131 I and no less than 99,0% in terms of organic compounds of iodine (CH 3 131 I); the dust capacity amounts to a value above 50 g/m 2 . The obtained results of tests comply with the design requirements imposed on the PFS filter-sorber module. (authors)

  10. Spatial patterns of the frog Oophaga pumilio in a plantation system are consistent with conspecific attraction.

    Science.gov (United States)

    Folt, Brian; Donnelly, Maureen A; Guyer, Craig

    2018-03-01

    The conspecific attraction hypothesis predicts that individuals are attracted to conspecifics because conspecifics may be cues to quality habitat and/or colonists may benefit from living in aggregations. Poison frogs (Dendrobatidae) are aposematic, territorial, and visually oriented-three characteristics which make dendrobatids an appropriate model to test for conspecific attraction. In this study, we tested this hypothesis using an extensive mark-recapture dataset of the strawberry poison frog ( Oophaga pumilio ) from La Selva Biological Station, Costa Rica. Data were collected from replicate populations in a relatively homogenous Theobroma cacao plantation, which provided a unique opportunity to test how conspecifics influence the spatial ecology of migrants in a controlled habitat with homogenous structure. We predicted that (1) individuals entering a population would aggregate with resident adults, (2) migrants would share sites with residents at a greater frequency than expected by chance, and (3) migrant home ranges would have shorter nearest-neighbor distances (NND) to residents than expected by chance. The results were consistent with these three predictions: Relative to random simulations, we observed significant aggregation, home-range overlap, and NND distribution functions in four, five, and six, respectively, of the six migrant-resident groups analyzed. Conspecific attraction may benefit migrant O. pumilio by providing cues to suitable home sites and/or increasing the potential for social interactions with conspecifics; if true, these benefits should outweigh the negative effects of other factors associated with aggregation. The observed aggregation between migrant and resident O. pumilio is consistent with conspecific attraction in dendrobatid frogs, and our study provides rare support from a field setting that conspecific attraction may be a relevant mechanism for models of anuran spatial ecology.

  11. How to consistently make your product, technology or system more environmentally-sustainable?

    DEFF Research Database (Denmark)

    Laurent, Alexis; Cosme, Nuno Miguel Dias; Molin, Christine

    Human activities are currently uns ustainable, causing many damages to ecosystems, human health and natural resources. In this setting, the development of new products and technologies has been increasingly required to relate to sustainability and ensure that such development goes hand -in-hand w...... of the system. We rely on state-of -the-art science in the food sector, the aquaculture sector and the energy sector to showcase and illustrate the potential of LCA to undertake the environmental sustainability challenge and support product/technology/system development....

  12. Direct calculation of self-consistent π bond orders in conjugated systems and pairing relations

    International Nuclear Information System (INIS)

    Castro, A.F.

    1982-01-01

    Pairing relations in excited states of conjugated systems which satisfy to a given symmetry with a Pariser-Parr-Pople-like (PPP) calculation are studied. Six π - electron systems are considered having a symmetry axis which does not cross π centers following a treatment which permits the direct obtainment of the bond order matrix based on Hall's method. Pairing relations are looked for, too, using particular solutions when U(3) groups is applied. Pyridazine molecules are used in order to test the results. (L.C.) [pt

  13. Simulation of distributed parameter system consisting of charged and neutral particles

    International Nuclear Information System (INIS)

    Grover, P.S.; Sinha, K.V.

    1986-01-01

    The time-dependent behavior of positively charged light particles have been simulated in an assembly of heavy gas atoms. The system is formulated in terms of partial differential equation. The stability and convergence of the numerical algorithm has been examined. Using this formulation effects of external electric field and temperature have been investigated on the lifetime and distribution function characteristics of charged particles

  14. Cosmological evolution and Solar System consistency of massive scalar-tensor gravity

    Science.gov (United States)

    de Pirey Saint Alby, Thibaut Arnoulx; Yunes, Nicolás

    2017-09-01

    The scalar-tensor theory of Damour and Esposito-Farèse recently gained some renewed interest because of its ability to suppress modifications to general relativity in the weak field, while introducing large corrections in the strong field of compact objects through a process called scalarization. A large sector of this theory that allows for scalarization, however, has been shown to be in conflict with Solar System observations when accounting for the cosmological evolution of the scalar field. We here study an extension of this theory by endowing the scalar field with a mass to determine whether this allows the theory to pass Solar System constraints upon cosmological evolution for a larger sector of coupling parameter space. We show that the cosmological scalar field goes first through a quiescent phase, similar to the behavior of a massless field, but then it enters an oscillatory phase, with an amplitude (and frequency) that decays (and grows) exponentially. We further show that after the field enters the oscillatory phase, its effective energy density and pressure are approximately those of dust, as expected from previous cosmological studies. Due to these oscillations, we show that the scalar field cannot be treated as static today on astrophysical scales, and so we use time-dependent perturbation theory to compute the scalar-field-induced modifications to Solar System observables. We find that these modifications are suppressed when the mass of the scalar field and the coupling parameter of the theory are in a wide range, allowing the theory to pass Solar System constraints, while in principle possibly still allowing for scalarization.

  15. Effect of a new drug releasing system on microencapsulated islet transplantation

    Science.gov (United States)

    Lu, Binjie; Gao, Qingkun; Liu, Rui; Ren, Ming; Wu, Yan; Jiang, Zaixing; Zhou, Yi

    2015-01-01

    Objective: This study aimed to develop a novel release system for grafted islets. Materials and methods: A graphene oxide-FTY720 release system was constructed to test the drug loading and releasing capacity. The recipient rats were divided into four groups as following: Experiment group A (EG A) and B (EG B); Control group A (CG A) and B (CG B). In each group, (2000±100) IEQ microencapsulated islets were implanted into the abdominal cavity of the recipients with oral FTY720, local graphene oxide-FTY720 injection, without immunosuppressants, and with graphene oxide-saturated solution respectively. We detected the immunological data, the blood glucose level, and pericapsular overgrowth to show the transplantation effect. Results: 31% of adsorptive FTY720 was released within 6 h, and 82% of FTY720 was released within 48 h. From day 5 to 8, the amount of PBL in EG B was significantly less than those in EG A (PGraphene oxide-FTY720 complex showed a drug releasing effect. Local application of graphene-FTY720 releasing system could decrease the amount of peripheral blood lymphocytes (PBL) and the percentage of CD3 and CD8 T lymphocytes in blood for longer time than oral drug application. This releasing system could achieve a better blood glucose control. PMID:26722425

  16. Measurement of semiochemical release rates with a dedicated environmental control system

    Science.gov (United States)

    Heping Zhu; Harold W. Thistle; Christopher M. Ranger; Hongping Zhou; Brian L. Strom

    2015-01-01

    Insect semiochemical dispensers are commonly deployed under variable environmental conditions over a specified period. Predictions of their longevity are hampered by a lack of methods to accurately monitor and predict how primary variables affect semiochemical release rate. A system was constructed to precisely determine semiochemical release rates under...

  17. Calculation notes in support of ammonia releases from waste tank ventilation systems

    International Nuclear Information System (INIS)

    Wojdac, L.F.

    1996-01-01

    Ammonia is generated in waste tanks via the degradation of nitrogen compounds. The ammonia is released from the liquids by a mechanism which is dependent on temperature, pH, ionic strength and ammonia concentration. The release of ammonia to the environment occurs via diffusion of ammonia through a stagnant air mass and into the ventilation system

  18. Development and evaluation of a biocide release system for prolonged antifungal activity in finishing materials

    NARCIS (Netherlands)

    Eversdijk, J.; Erich, S.J.F.; Hermanns, S.P.M.; Adan, O.C.G.; Bolle, de M.; Meyer, de K.; Bylemans, D.; Bekker, M.; Cate, ten A.T.

    2012-01-01

    This paper focuses on the use of modified nano-clay particles as a controlled release system for biocides from building materials. Different (model) biocides were incorporated in a biocide/nano-clay composite and subsequently the release of the biocides was monitored under different environmental

  19. Regulation of somatostatin release in the nervous system of the rat

    International Nuclear Information System (INIS)

    Sheppard, M.

    1979-08-01

    This thesis represents the work done to study the release of somatostatin from the rat central nervous system in vitro, providing some evidence for a physiological role for somatostatin. Somatostatin was measured by a sensitive and specific radioimmunoassay devoloped in the laboratory. Chapter 2 reviews the literature on hypothalamic peptides and control of an anterior pituitary function, somatostatin, other central nervous system peptides and neurosecretion. Chapter 3 describes the central nervous system tissue dissection technique, the radioimmunoassay for somatostatin and the tissue levels of somatostatin immunoreactivity in different areas of the central nervous system. Chapter 4 deals with the release of immunoreactive somatostatin from incubated rat hypothalamus in vitro and the influence of other hormones and neuropeptides on this release. Chapter 5 describes the preparation of isolated nerve endings (synaptosomes) from four different areas of rat brain, the localisation of somatostatin to the synaptosome fraction of brain homogenates and the release of somatostatin from these synaptosomes. Chapter 6 deals with the release of somatostatin from incubated rat spinal cord in vitro. Chapter 7 presents the results of the characterisation of released immunoreactive material, the technique utilised being serial dilution of immunoreactive material and comparison to the standard curve, Sephadex gel chromatography, affinity chromatography, and the effect of released immunoreactive somatostatin on growth hormone release from perifused hemipituitaries in vitro, i.e. biological activity. Chapter 8 provides a summary of the main conclusions reached in this study and is followed by the Appendix describing chemical and biochemical methods, histological techniques, and statistical methods

  20. Self-consistent random phase approximation - application to systems of strongly correlated fermions

    International Nuclear Information System (INIS)

    Jemai, M.

    2004-07-01

    In the present thesis we have applied the self consistent random phase approximation (SCRPA) to the Hubbard model with a small number of sites (a chain of 2, 4, 6,... sites). Earlier SCRPA had produced very good results in other models like the pairing model of Richardson. It was therefore interesting to see what kind of results the method is able to produce in the case of a more complex model like the Hubbard model. To our great satisfaction the case of two sites with two electrons (half-filling) is solved exactly by the SCRPA. This may seem a little trivial but the fact is that other respectable approximations like 'GW' or the approach with the Gutzwiller wave function yield results still far from exact. With this promising starting point, the case of 6 sites at half filling was considered next. For that case, evidently, SCRPA does not any longer give exact results. However, they are still excellent for a wide range of values of the coupling constant U, covering for instance the phase transition region towards a state with non zero magnetisation. We consider this as a good success of the theory. Non the less the case of 4 sites (a plaquette), as indeed all cases with 4n sites at half filling, turned out to have a problem because of degeneracies at the Hartree Fock level. A generalisation of the present method, including in addition to the pairs, quadruples of Fermions operators (called second RPA) is proposed to also include exactly the plaquette case in our approach. This is therefore a very interesting perspective of the present work. (author)

  1. Interface Consistency

    DEFF Research Database (Denmark)

    Staunstrup, Jørgen

    1998-01-01

    This paper proposes that Interface Consistency is an important issue for the development of modular designs. Byproviding a precise specification of component interfaces it becomes possible to check that separately developedcomponents use a common interface in a coherent matter thus avoiding a very...... significant source of design errors. Awide range of interface specifications are possible, the simplest form is a syntactical check of parameter types.However, today it is possible to do more sophisticated forms involving semantic checks....

  2. Generation-based memory synchronization in a multiprocessor system with weakly consistent memory accesses

    Energy Technology Data Exchange (ETDEWEB)

    Ohmacht, Martin

    2017-08-15

    In a multiprocessor system, a central memory synchronization module coordinates memory synchronization requests responsive to memory access requests in flight, a generation counter, and a reclaim pointer. The central module communicates via point-to-point communication. The module includes a global OR reduce tree for each memory access requesting device, for detecting memory access requests in flight. An interface unit is implemented associated with each processor requesting synchronization. The interface unit includes multiple generation completion detectors. The generation count and reclaim pointer do not pass one another.

  3. Ternary systems, consist of erbium nitrates, water and nitrates of pyridines, quinolines

    International Nuclear Information System (INIS)

    Starikova, L.I.; Zhuravlev, E.F.; Khalfina, L.R.

    1979-01-01

    At 25 and 50 deg C investigated is solubility of solid phases in ternary water salt systems: erbium nitrate-pyridine nitrate-water; erbium nitrate-quinoline nitrate-water. Formation of congruently soluble compounds of the Er(NO 3 ) 3 x2C 5 H 5 NxHNO 3 , Er(NO 3 ) 3 x2C 9 H 7 NxHNO 3 x4H 2 O composition is established. X-ray phase and thermogravimetric analyses have been carried out

  4. An Approach to Verifying Completeness and Consistency in a Rule-Based Expert System.

    Science.gov (United States)

    1982-08-01

    peolea with the se e S knowlede base by observing en t om. W0hile thorough testing is an "samt4 Pert of V*flfyL the ooIlst4ftl and capleteness of a...physicians at Stanford’s Oncology Day Care Center on the management of patients who are on experimental treatment protocols. These protocols serve to...for oncology protocol management . Prooceedings of 7th IJCAI, pp. 876- 881, Vancouver, B.C., August 1981. I. van Melle, W. A Domain-Independent system

  5. Generation-based memory synchronization in a multiprocessor system with weakly consistent memory accesses

    Science.gov (United States)

    Ohmacht, Martin

    2014-09-09

    In a multiprocessor system, a central memory synchronization module coordinates memory synchronization requests responsive to memory access requests in flight, a generation counter, and a reclaim pointer. The central module communicates via point-to-point communication. The module includes a global OR reduce tree for each memory access requesting device, for detecting memory access requests in flight. An interface unit is implemented associated with each processor requesting synchronization. The interface unit includes multiple generation completion detectors. The generation count and reclaim pointer do not pass one another.

  6. Reducing Friction and Wear of Tribological Systems through Hybrid Tribofilm Consisting of Coating and Lubricants

    Directory of Open Access Journals (Sweden)

    Shuichiro Yazawa

    2014-06-01

    Full Text Available The role of surface protective additives becomes vital when operating conditions become severe and moving components operate in a boundary lubrication regime. After protecting film is slowly removed by rubbing, it can regenerate through the tribochemical reaction of the additives at the contact. However, there are limitations about the regeneration of the protecting film when additives are totally consumed. On the other hand, there are a lot of hard coatings to protect the steel surface from wear. These can enable the functioning of tribological systems, even in adverse lubrication conditions. However, hard coatings usually make the friction coefficient higher, because of their high interfacial shear strength. Amongst hard coatings, diamond-like carbon (DLC is widely used, because of its relatively low friction and superior wear resistance. In practice, conventional lubricants that are essentially formulated for a steel/steel surface are still used for lubricating machine component surfaces provided with protective coatings, such as DLCs, despite the fact that the surface properties of coatings are quite different from those of steel. It is therefore important that the design of additive molecules and their interaction with coatings should be re-considered. The main aim of this paper is to discuss the DLC and the additive combination that enable tribofilm formation and effective lubrication of tribological systems.

  7. Flavour release of aldehydes and diacetyl in oil/water systems

    DEFF Research Database (Denmark)

    Haahr, Anne-Mette; Bredie, W. L. P.; Stahnke, Louise Heller

    2000-01-01

    from the pure oil. The release over time for diacetyl and (E,E)-2,4-hexadienal showed a linear relationship in all systems. The other compounds followed an exponential relationship between the time and the fraction released in the aqueous systems. It was demonstrated that the release of the volatile...... compounds was dependent on the chain length, the degree of unsaturation as well as the characteristics of the model system. (C) 2000 Elsevier Science Ltd. All rights reserved.......The concentration- and time-dependent release of three C-6-aldehydes, six C-9-aldehydes and diacetyl was studied in model systems. The systems were water, rapeseed oil and oil-in-water emulsions. Dynamic headspace sampling was used to collect the volatile compounds. In the concentration...

  8. Tile drainage phosphorus loss with long-term consistent cropping systems and fertilization.

    Science.gov (United States)

    Zhang, T Q; Tan, C S; Zheng, Z M; Drury, C F

    2015-03-01

    Phosphorus (P) loss in tile drainage water may vary with agricultural practices, and the impacts are often hard to detect with short-term studies. We evaluated the effects of long-term (≥43 yr) cropping systems (continuous corn [CC], corn-oats-alfalfa-alfalfa rotation [CR], and continuous grass [CS]) and fertilization (fertilization [F] vs. no-fertilization [NF]) on P loss in tile drainage water from a clay loam soil over a 4-yr period. Compared with NF, long-term fertilization increased concentrations and losses of dissolved reactive P (DRP), dissolved unreactive P (DURP), and total P (TP) in tile drainage water, with the increments following the order: CS > CR > CC. Dissolved P (dissolved reactive P [DRP] and dissolved unreactive P [DURP]) was the dominant P form in drainage outflow, accounting for 72% of TP loss under F-CS, whereas particulate P (PP) was the major form of TP loss under F-CC (72%), F-CR (62%), NF-CS (66%), NF-CC (74%), and NF-CR (72%). Dissolved unreactive P played nearly equal roles as DRP in P losses in tile drainage water. Stepwise regression analysis showed that the concentration of P (DRP, DURP, and PP) in tile drainage flow, rather than event flow volume, was the most important factor contributing to P loss in tile drainage water, although event flow volume was more important in PP loss than in dissolved P loss. Continuous grass significantly increased P loss by increasing P concentration and flow volume of tile drainage water, especially under the fertilization treatment. Long-term grasslands may become a significant P source in tile-drained systems when they receive regular P addition. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  9. Drug release control and system understanding of sucrose esters matrix tablets by artificial neural networks.

    Science.gov (United States)

    Chansanroj, Krisanin; Petrović, Jelena; Ibrić, Svetlana; Betz, Gabriele

    2011-10-09

    Artificial neural networks (ANNs) were applied for system understanding and prediction of drug release properties from direct compacted matrix tablets using sucrose esters (SEs) as matrix-forming agents for controlled release of a highly water soluble drug, metoprolol tartrate. Complexity of the system was presented through the effects of SE concentration and tablet porosity at various hydrophilic-lipophilic balance (HLB) values of SEs ranging from 0 to 16. Both effects contributed to release behaviors especially in the system containing hydrophilic SEs where swelling phenomena occurred. A self-organizing map neural network (SOM) was applied for visualizing interrelation among the variables and multilayer perceptron neural networks (MLPs) were employed to generalize the system and predict the drug release properties based on HLB value and concentration of SEs and tablet properties, i.e., tablet porosity, volume and tensile strength. Accurate prediction was obtained after systematically optimizing network performance based on learning algorithm of MLP. Drug release was mainly attributed to the effects of SEs, tablet volume and tensile strength in multi-dimensional interrelation whereas tablet porosity gave a small impact. Ability of system generalization and accurate prediction of the drug release properties proves the validity of SOM and MLPs for the formulation modeling of direct compacted matrix tablets containing controlled release agents of different material properties. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Neonatal protection by an innate immune system of human milk consisting of oligosaccharides and glycans.

    Science.gov (United States)

    Newburg, D S

    2009-04-01

    This review discusses the role of human milk glycans in protecting infants, but the conclusion that the human milk glycans constitute an innate immune system whereby the mother protects her offspring may have general applicability in all mammals, including species of commercial importance. Infants that are not breastfed have a greater incidence of severe diarrhea and respiratory diseases than those who are breastfed. In the past, this had been attributed primarily to human milk secretory antibodies. However, the oligosaccharides are major components of human milk, and milk is also rich in other glycans, including glycoproteins, mucins, glycosaminoglycans, and glycolipids. These milk glycans, especially the oligosaccharides, are composed of thousands of components. The milk factor that promotes gut colonization by Bifidobacterium bifidum was found to be a glycan, and such prebiotic characteristics may contribute to protection against infectious agents. However, the ability of human milk glycans to protect the neonate seems primarily to be due to their inhibition of pathogen binding to their host cell target ligands. Many such examples include specific fucosylated oligosaccharides and glycans that inhibit specific pathogens. Most human milk oligosaccharides are fucosylated, and their production depends on fucosyltransferase enzymes; mutations in these fucosyltransferase genes are common and underlie the various Lewis blood types in humans. Variable expression of specific fucosylated oligosaccharides in milk, also a function of these genes (and maternal Lewis blood type), is significantly associated with the risk of infectious disease in breastfed infants. Human milk also contains major quantities and large numbers of sialylated oligosaccharides, many of which are also present in bovine colostrum. These could similarly inhibit several common viral pathogens. Moreover, human milk oligosaccharides strongly attenuate inflammatory processes in the intestinal mucosa. These

  11. Evaluation of quality of life and sexual functioning of women using levonorgestrel-releasing intrauterine contraceptive system--Mirena.

    Science.gov (United States)

    Skrzypulec, Violetta; Drosdzol, Agnieszka

    2008-12-01

    The advantages ensuing from the high contraceptive efficacy, positive effect on the parameters of the menstrual cycle as well as other values of the levonorgestrel-releasing intrauterine system may play an important role in women's sexual life. The aim of the study was to evaluate the effect of the levonorgestrel-releasing intrauterine system on the quality of life and sexual functioning of women. The research encompassed 200 women aged between 30 and 45. 52 women using the levonorgestrel-releasing intrauterine system were qualified to the study as the research group (Mirena Group). The control groups consisted of 48 women using a different type of intrauterine device (Control Group I--Other IUD) and 50 women using no contraception (Control Group II). A specific questionnaire with a general part concerning socio-demographic conditions, a part dealing with contraception and Polish version of self-evaluation inventories: Short Form-36 Health Survey, Female Sexual Function Index and Mell-Krat Scale was used as a research tool. Quality of life parameters for women using the Mirena system were higher than for the control groups, especially in the aspect of general health, energy/fatigue and emotional well-being. A significant beneficial effect of the levonorgestrel-releasing intrauterine system on sexual functioning (sexual desire and arousal) was also revealed in the study. Sexual dysfunctions were diagnosed in 20.8% of Other IUD, 34.7% of Control Group II and 9.6% of Mirena Group. Levonorgestrel-releasing intrauterine system increases female quality of life and sexual functioning parameters.

  12. Final Scientific/Technical Report "Arc Tube Coating System for Color Consistency"

    Energy Technology Data Exchange (ETDEWEB)

    Buelow, Roger [Energy Focus, Inc., Solon, OH (United States); Jenson, Chris [Energy Focus, Inc., Solon, OH (United States); Kazenski, Keith [Energy Focus, Inc., Solon, OH (United States)

    2013-03-21

    DOE has enabled the use of coating materials using low cost application methods on light sources to positively affect the output of those sources. The coatings and light source combinations have shown increased lumen output of LED fixtures (1.5%-2.0%), LED arrays (1.4%) and LED powered remote phosphor systems Philips L-Prize lamp (0.9%). We have also demonstrated lifetime enhancements (3000 hrs vs 8000 hrs) and shifting to higher CRI (51 to 65) in metal halide high intensity discharge lamps with metal oxide coatings. The coatings on LEDs and LED products are significant as the market is moving increasingly more towards LED technology. Enhancements in LED performance are demonstrated in this work through the use of available materials and low cost application processes. EFOI used low refractive index fluoropolymers and low cost dipping processes for application of the material to surfaces related to light transmission of LEDs and LED products. Materials included Teflon AF, an amorphous fluorinated polymer and fluorinated acrylic monomers. The DOE SSL Roadmap sets goals for LED performance moving into the future. EFOI's coating technology is a means to shift the performance curve for LEDs. This is not limited to one type of LED, but is relevant across LED technologies. The metal halide work included the use of sol-gel solutions resulting in silicon dioxide and titanium dioxide coatings on the quartz substrates of the metal halide arc tubes. The coatings were applied using low cost dipping processes.

  13. Mutual Inductance Problem for a System Consisting of a Current Sheet and a Thin Metal Plate

    Science.gov (United States)

    Fulton, J. P.; Wincheski, B.; Nath, S.; Namkung, M.

    1993-01-01

    Rapid inspection of aircraft structures for flaws is of vital importance to the commercial and defense aircraft industry. In particular, inspecting thin aluminum structures for flaws is the focus of a large scale R&D effort in the nondestructive evaluation (NDE) community. Traditional eddy current methods used today are effective, but require long inspection times. New electromagnetic techniques which monitor the normal component of the magnetic field above a sample due to a sheet of current as the excitation, seem to be promising. This paper is an attempt to understand and analyze the magnetic field distribution due to a current sheet above an aluminum test sample. A simple theoretical model, coupled with a two dimensional finite element model (FEM) and experimental data will be presented in the next few sections. A current sheet above a conducting sample generates eddy currents in the material, while a sensor above the current sheet or in between the two plates monitors the normal component of the magnetic field. A rivet or a surface flaw near a rivet in an aircraft aluminum skin will disturb the magnetic field, which is imaged by the sensor. Initial results showed a strong dependence of the flaw induced normal magnetic field strength on the thickness and conductivity of the current-sheet that could not be accounted for by skin depth attenuation alone. It was believed that the eddy current imaging method explained the dependence of the thickness and conductivity of the flaw induced normal magnetic field. Further investigation, suggested the complexity associated with the mutual inductance of the system needed to be studied. The next section gives an analytical model to better understand the phenomenon.

  14. The smart aerial release machine, a universal system for applying the sterile insect technique: Manuscript Draft

    International Nuclear Information System (INIS)

    Mubarqui, Leal Ruben; Perez, Rene Cano; Klad, Roberto Angulo; Lopez, Jose L. Zavale; Parker, Andrew; Seck, Momar Talla; Sall, Baba; Bouyer, Jeremy

    2014-01-01

    Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse. Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software). The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata) and we obtained better dispersal homogeneity (% of positive traps, p < 0.001) for both species and better recapture rates for Anastrepha ludens (p < 0.001), especially at low release densities (<1500 per ha). We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km"2 for tsetse flies up to 600 000 flies/km"2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  15. The smart aerial release machine, a universal system for applying the sterile insect technique.

    Directory of Open Access Journals (Sweden)

    Ruben Leal Mubarqui

    Full Text Available Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse.Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software. The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata and we obtained better dispersal homogeneity (% of positive traps, p<0.001 for both species and better recapture rates for Anastrepha ludens (p<0.001, especially at low release densities (<1500 per ha. We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km2 for tsetse flies up to 600,000 flies/km2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  16. Textile slow-release systems with medical applications

    NARCIS (Netherlands)

    ten Breteler, M.R.; Nierstrasz, Vincent; Warmoeskerken, Marinus

    2002-01-01

    In the development of medical drug delivery systems, attention has been increasingly focused on slow- or controlled delivery systems in order to achieve an optimal therapeutic effect. Since the administration of drugs often requires a defined or minimum effective dosage in the human body, more

  17. Consistent analysis of peripheral reaction channels and fusion for the 16,18O+58Ni systems

    International Nuclear Information System (INIS)

    Alves, J.J.S.; Gomes, P.R.S.; Lubian, J.; Chamon, L.C.; Pereira, D.; Anjos, R.M.; Rossi, E.S.; Silva, C.P.; Alvarez, M.A.G.; Nobre, G.P.A.; Gasques, L.R.

    2005-01-01

    We have measured elastic scattering and peripheral reaction channel cross sections for the 16,18 O+ 58 Ni systems at ELab=46 MeV. The data were analyzed through extensive coupled-channel calculations. It was investigated the consistency of the present analysis with a previous one at sub-barrier energies. Experimental fusion cross sections for these systems are also compared with the corresponding predictions of the coupled-channel calculations

  18. A sample design for globally consistent biomass estimation using lidar data from the Geoscience Laser Altimeter System (GLAS)

    Science.gov (United States)

    Sean P. Healey; Paul L. Patterson; Sassan S. Saatchi; Michael A. Lefsky; Andrew J. Lister; Elizabeth A. Freeman

    2012-01-01

    Lidar height data collected by the Geosciences Laser Altimeter System (GLAS) from 2002 to 2008 has the potential to form the basis of a globally consistent sample-based inventory of forest biomass. GLAS lidar return data were collected globally in spatially discrete full waveform "shots," which have been shown to be strongly correlated with aboveground forest...

  19. Controlled release of simvastatin from biomimetic β-TCP drug delivery system.

    Directory of Open Access Journals (Sweden)

    Joshua Chou

    Full Text Available Simvastatin have been shown to induce bone formation and there is currently a urgent need to develop an appropriate delivery system to sustain the release of the drug to increase therapeutic efficacy whilst reducing side effects. In this study, a novel drug delivery system for simvastatin by means of hydrothermally converting marine exoskeletons to biocompatible beta-tricalcium phosphate was investigated. Furthermore, the release of simvastatin was controlled by the addition of an outer apatite coating layer. The samples were characterized by x-ray diffraction analysis, fourier transform infrared spectroscopy, scanning electron microscopy and mass spectroscopy confirming the conversion process. The in-vitro dissolution of key chemical compositional elements and the release of simvastatin were measured in simulated body fluid solution showing controlled release with reduction of approximately 25% compared with un-coated samples. This study shows the potential applications of marine structures as a drug delivery system for simvastatin.

  20. A space release/deployment system actuated by shape memory wires

    Science.gov (United States)

    Fragnito, Marino; Vetrella and, Sergio

    2002-11-01

    In this paper, the design of an innovative hold down/release and deployment device actuated by shape memory wires, to be used for the first time for the S MA RT microsatellite solar wings is shown. The release and deployment mechanisms are actuated by a Shape Memory wire (Nitinol), which allows a complete symmetrical and synchronous release, in a very short time, of the four wings in pairs. The hold down kinematic mechanism is preloaded to avoid vibration nonlinearities and unwanted deployment at launch. The deployment mechanism is a simple pulley system. The stiffness of the deployed panel-hinge system needs to be dimensioned in order to meet the on-orbit requirement for attitude control. One-way roller clutches are used to keep the panel at the desired angle during the mission. An ad hoc software has been developed to simulate both the release and deployment operations, coupling the SMA wire behavior with the system mechanics.

  1. Semi-discrete approximations to nonlinear systems of conservation laws; consistency and L(infinity)-stability imply convergence. Final report

    International Nuclear Information System (INIS)

    Tadmor, E.

    1988-07-01

    A convergence theory for semi-discrete approximations to nonlinear systems of conservation laws is developed. It is shown, by a series of scalar counter-examples, that consistency with the conservation law alone does not guarantee convergence. Instead, a notion of consistency which takes into account both the conservation law and its augmenting entropy condition is introduced. In this context it is concluded that consistency and L(infinity)-stability guarantee for a relevant class of admissible entropy functions, that their entropy production rate belongs to a compact subset of H(loc)sup -1 (x,t). One can now use compensated compactness arguments in order to turn this conclusion into a convergence proof. The current state of the art for these arguments includes the scalar and a wide class of 2 x 2 systems of conservation laws. The general framework of the vanishing viscosity method is studied as an effective way to meet the consistency and L(infinity)-stability requirements. How this method is utilized to enforce consistency and stability for scalar conservation laws is shown. In this context we prove, under the appropriate assumptions, the convergence of finite difference approximations (e.g., the high resolution TVD and UNO methods), finite element approximations (e.g., the Streamline-Diffusion methods) and spectral and pseudospectral approximations (e.g., the Spectral Viscosity methods)

  2. Modeling the modified drug release from curved shape drug delivery systems - Dome Matrix®.

    Science.gov (United States)

    Caccavo, D; Barba, A A; d'Amore, M; De Piano, R; Lamberti, G; Rossi, A; Colombo, P

    2017-12-01

    The controlled drug release from hydrogel-based drug delivery systems is a topic of large interest for research in pharmacology. The mathematical modeling of the behavior of these systems is a tool of emerging relevance, since the simulations can be of use in the design of novel systems, in particular for complex shaped tablets. In this work a model, previously developed, was applied to complex-shaped oral drug delivery systems based on hydrogels (Dome Matrix®). Furthermore, the model was successfully adopted in the description of drug release from partially accessible Dome Matrix® systems (systems with some surfaces coated). In these simulations, the erosion rate was used asa fitting parameter, and its dependence upon the surface area/volume ratio and upon the local fluid dynamics was discussed. The model parameters were determined by comparison with the drug release profile from a cylindrical tablet, then the model was successfully used for the prediction of the drug release from a Dome Matrix® system, for simple module configuration and for module assembled (void and piled) configurations. It was also demonstrated that, given the same initial S/V ratio, the drug release is independent upon the shape of the tablets but it is only influenced by the S/V evolution. The model reveals itself able to describe the observed phenomena, and thus it can be of use for the design of oral drug delivery systems, even if complex shaped. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Formal Modeling and Verification of Interlocking Systems Featuring Sequential Release

    DEFF Research Database (Denmark)

    Vu, Linh Hong; Haxthausen, Anne Elisabeth; Peleska, Jan

    2015-01-01

    In this paper, we present a method and an associated tool suite for formal verification of the new ETCS level 2 based Danish railway interlocking systems. We have made a generic and reconfigurable model of the system behavior and generic high-level safety properties. This model accommodates seque...... SMT based bounded model checking (BMC) and inductive reasoning, we are able to verify the properties for model instances corresponding to railway networks of industrial size. Experiments also show that BMC is efficient for finding bugs in the railway interlocking designs....

  4. Formal Modeling and Verification of Interlocking Systems Featuring Sequential Release

    DEFF Research Database (Denmark)

    Vu, Linh Hong; Haxthausen, Anne Elisabeth; Peleska, Jan

    2014-01-01

    In this paper, we present a method and an associated tool suite for formal verification of the new ETCS level 2 based Danish railway interlocking systems. We have made a generic and reconfigurable model of the system behavior and generic high-level safety properties. This model accommodates seque...... SMT based bounded model checking (BMC) and inductive reasoning, we are able to verify the properties for model instances corresponding to railway networks of industrial size. Experiments also show that BMC is efficient for finding bugs in the railway interlocking designs....

  5. Development of modified-release tablets of zolpidem tartrate by biphasic quick/slow delivery system.

    Science.gov (United States)

    Mahapatra, Anjan Kumar; Sameeraja, N H; Murthy, P N

    2015-06-01

    Zolpidem tartrate is a non-benzodiazepine analogue of imidazopyridine of sedative and hypnotic category. It has a short half-life with usual dosage regimen being 5 mg, two times a day, or 10 mg, once daily. The duration of action is considered too short in certain circumstances. Thus, it is desirable to lengthen the duration of action. The formulation design was implemented by preparing extended-release tablets of zolpidem tartrate using the biphasic delivery system technology, where sodium starch glycolate acts as a superdisintegrant in immediate-release part and hydroxypropyl methyl cellulose as a release retarding agent in extended-release core. Tablets were prepared by direct compression. Both the core and the coat contained the drug. The pre-compression blends were evaluated for angle of repose, bulk density, and compressibility index. The tablets were evaluated for thickness, hardness, weight variation test, friability, and in vitro release studies. No interaction was observed between zolpidem tartrate and excipients from the Fourier transform infrared spectroscopy and differential scanning calorimetry analysis. The results of all the formulations prepared were compared with reference product Stilnoct®. Optimized formulations showed release patterns that match the United States Pharmacopeia (USP) guidelines for zolpidem tartrate extended-release tablets. The mechanism of drug release was studied using different mathematical models, and the optimized formulation has shown Fickian diffusion. Accelerated stability studies were performed on the optimized formulation.

  6. A novel and alternative approach to controlled release drug delivery system based on solid dispersion technique

    Directory of Open Access Journals (Sweden)

    Tapan Kumar Giri

    2012-12-01

    Full Text Available The solid dispersion method was originally used to improve the dissolution properties and the bioavailability of poorly water soluble drugs by dispersing them into water soluble carriers. In addition to the above, dissolution retardation through solid dispersion technique using water insoluble and water swellable polymer for the development of controlled release dosage forms has become a field of interest in recent years. Development of controlled release solid dispersion has a great advantage for bypassing the risk of a burst release of drug; since the structure of the solid dispersion is monolithic where drug molecules homogeneously disperse. Despite the remarkable potential and extensive research being conducted on controlled release solid dispersion system, commercialization and large scale production are limited. The author expects that recent technological advances may overcome the existing limitations and facilitate the commercial utilization of the techniques for manufacture of controlled release solid dispersions. This article begins with an overview of the different carriers being used for the preparation of controlled release solid dispersion and also different techniques being used for the purpose. Kinetics of drug release from these controlled release solid dispersions and the relevant mathematical modeling have also been reviewed in this manuscript.

  7. Controlled release of glaucocalyxin - a self-nanoemulsifying system from osmotic pump tablets with enhanced bioavailability.

    Science.gov (United States)

    Yanfei, Miao; Guoguang, Chen; Lili, Ren; Pingkai, Ouyang

    2017-03-01

    The purpose of this study was to develop a new formulation to enhance the bioavailability simultaneously with controlled release of glaucocalyxin A (GLA). In this study, controlled release of GLA was achieved by the osmotic release strategy taking advantage of the bioavailability enhancing capacity of self-nanoemulsifying drug delivery systems (SNEDDS). The formulation of GLA-SNEDDS was selected by the solubility and pseudoternary-phase diagrams studies. The prepared GLA-SNEDDS formulations were characterized for self-emulsification time, effect of pH and robustness to dilution, droplet size analysis and zeta potential. The optimized GLA-SNEDDS were used to prepare GLA-SNEDDS osmotic pump tablet via direct powder compression method. The effect of formulation variables on the release characteristic was investigated. GLA-SNEDDS osmotic pump tablets were administered to beagle dogs and their pharmacokinetics were compared to GLA and GLA-SNEDDS as a control. In vitro drug release studies indicated that the GLA-SNEDDS osmotic pump tablet showed sustained release profiles with 90% released within 12 h. Pharmacokinetic study showed steady blood GLA with prolonged T max and mean residence time (MRT), and enhanced bioavailability for GLA-SNEDDS osmotic pump tablet. It was concluded that simultaneous controlling on GLA release and enhanced bioavailability had been achieved by a combination of osmotic pump tablet and SNEDDS.

  8. THE ACCUMULATION AND RELEASE OF ARSENIC FROM DISTRIBUTION SYSTEM SOLIDS

    Science.gov (United States)

    The recently promulgated Arsenic Rule will require that many new drinking water systems treat their water to remove arsenic. Iron based treatment technologies including iron removal and iron coagulation are effective at reducing arsenic in water because iron surfaces have a stron...

  9. THE ACCUMULATION AND RELEASE OF CONTAMINANTS FROM DISTRIBUTION SYSTEM SOLIDS

    Science.gov (United States)

    The recently promulgated Arsenic Rule will require that many new drinking water systems treat their water to remove arsenic. Iron based treatment technologies including iron removal and iron coagulation are effective at reducing arsenic in water because iron surfaces have a stron...

  10. Journal Bearing Analysis Suite Released for Planetary Gear System Evaluation

    Science.gov (United States)

    Brewe, David E.; Clark, David A.

    2005-01-01

    Planetary gear systems are an efficient means of achieving high reduction ratios with minimum space and weight. They are used in helicopter, aerospace, automobile, and many industrial applications. High-speed planetary gear systems will have significant dynamic loading and high heat generation. Hence, they need jet lubrication and associated cooling systems. For units operating in critical applications that necessitate high reliability and long life, that have very large torque loading, and that have downtime costs that are significantly greater than the initial cost, hydrodynamic journal bearings are a must. Computational and analytical tools are needed for sufficiently accurate modeling to facilitate optimal design of these systems. Sufficient physics is needed in the model to facilitate parametric studies of design conditions that enable optimal designs. The first transient journal bearing code to implement the Jacobsson-Floberg-Olsson boundary conditions, using a mass-conserving algorithm devised by Professor Emeritus Harold Elrod of Columbia University, was written by David E. Brewe of the U.S. Army at the NASA Lewis Research Center1 in 1983. Since then, new features and improved modifications have been built into the code by several contributors supported through Army and NASA funding via cooperative agreements with the University of Toledo (Professor Ted Keith, Jr., and Dr. Desikakary Vijayaraghavan) and National Research Council Programs (Dr. Vijayaraghavan). All this was conducted with the close consultation of Professor Elrod and the project management of David Brewe.

  11. A Comparative Study on the Lot Release Systems for Vaccines as of 2016.

    Science.gov (United States)

    Fujita, Kentaro; Naito, Seishiro; Ochiai, Masaki; Konda, Toshifumi; Kato, Atsushi

    2017-09-25

    Many countries have already established their own vaccine lot release system that is designed for each country's situation: while the World Health Organization promotes for the convergence of these regulatory systems so that vaccines of assured quality are provided globally. We conducted a questionnaire-based investigation of the lot release systems for vaccines in 7 countries and 2 regions. We found that a review of the summary protocol by the National Regulatory Authorities was commonly applied for the independent lot release of vaccines, however, we also noted some diversity between countries, especially in regard to the testing policy. Some countries and regions, including Japan, regularly tested every lot of vaccines, whereas the frequency of these tests was reduced in other countries and regions as determined based on the risk assessment of these products. Test items selected for the lot release varied among the countries or regions investigated, although there was a tendency to prioritize the potency tests. An understanding of the lot release policy may contribute to improving and harmonizing the lot release system globally in the future.

  12. Shroud cutting techniques and collection systems for secondary radioactivity release

    International Nuclear Information System (INIS)

    Yokoi, H.; Watanabe, A.; Uetake, N.; Shimura, T.; Omote, T.; Adachi, H.; Murakami, S.; Kobayashi, H.; Gotoh, M.

    2001-01-01

    Replacement of in-core shroud has been conducted as part of the preventive maintenance program in Tsuruga-1. The EDM (electric discharged machining) and plasma cutting methods were applied to in-core shroud cutting and secondary cutting in the DSP (dryer/separator pool), respectively. The cutting systems were improved in order to decrease radioactive secondary products. 1) Fundamental EDM cutting tests: fundamental EDM cutting tests were carried out in order to study secondary products. It could be presumed that volatile Co-carbonyl compound was generated by using a carbon electrode. The Ag/W electrode was effective as EDM electrode for in-core shroud cutting to prevent generation of Co-carbonyl compound and to decrease the total amount of secondary products. 2) In-core shroud cutting in RPV (reactor pressure vessel): EDM cutting system with the Ag/W electrode and collection system could keep a good environment during in-core shroud cutting in Tsuruga-1. Activity concentration was lower value than limitation of mask charge level, 4E-6 Bq/cm 3 , even near the water surface. 3) Secondary plasma cutting in DSP: the secondary cutting work was successful in the point of reduction of working period and radiation exposure. The amount of radiation exposure was reduced to 60% of the planned value, because of adequate decontamination of the working environment and reduction of number of torch maintenance tasks by improvements of the underwater cutting device

  13. Effects of Rating Training on Inter-Rater Consistency for Developing a Dental Hygiene Clinical Rater Qualification System

    Directory of Open Access Journals (Sweden)

    Jeong Ran Park

    2007-12-01

    Full Text Available We tried to develop itemized evaluation criteria and a clinical rater qualification system through rating training of inter-rater consistency for experienced clinical dental hygienists and dental hygiene clinical educators. A total of 15 clinical dental hygienists with 1-year careers participated as clinical examination candidates, while 5 dental hygienists with 3-year educations and clinical careers or longer participated as clinical raters. They all took the clinical examination as examinees. The results were compared, and the consistency of competence was measured. The comparison of clinical competence between candidates and clinical raters showed that the candidate group?占퐏 mean clinical competence ranged from 2.96 to 3.55 on a 5-point system in a total of 3 instruments (Probe, Explorer, Curet, while the clinical rater group?占퐏 mean clinical competence ranged from 4.05 to 4.29. There was a higher inter-rater consistency after education of raters in the following 4 items: Probe, Explorer, Curet, and insertion on distal surface. The mean score distribution of clinical raters ranged from 75% to 100%, which was more uniform in the competence to detect an artificial calculus than that of candidates (25% to 100%. According to the above results, there was a necessity in the operating clinical rater qualification system for comprehensive dental hygiene clinicians. Furthermore, in order to execute the clinical rater qualification system, it will be necessary to keep conducting a series of studies on educational content, time, frequency, and educator level.

  14. Factors affecting release of ethanol vapour in active modified atmosphere packaging systems for horticultural products

    Directory of Open Access Journals (Sweden)

    Weerawate Utto

    2014-04-01

    Full Text Available The active modified atmosphere packaging (active MAP system , which provides interactive postharvest control , using ethanol vapour controlled release, is one of the current interests in the development of active packaging for horticultural products. A number of published research work have discussed the relationship between the effectiveness of ethanol vapour and its concentration in the package headspace, including its effect on postharvest decay and physiological controls. This is of importance because a controlled release system should release and maintain ethanol vapour at effective concentrations during the desired storage period. A balance among the mass transfer processes of ethanol vapour in the package results in ethanol vapour accumulation in the package headspace. Key factors affecting these processes include ethanol loading, packaging material, packaged product and storage environment (temperature and relative h umidity. This article reviews their influences and discusses future work required to better understand their influences on ethanol vapour release and accumulations in active MAP.

  15. Bitcoin Meets Strong Consistency

    OpenAIRE

    Decker, Christian; Seidel, Jochen; Wattenhofer, Roger

    2014-01-01

    The Bitcoin system only provides eventual consistency. For everyday life, the time to confirm a Bitcoin transaction is prohibitively slow. In this paper we propose a new system, built on the Bitcoin blockchain, which enables strong consistency. Our system, PeerCensus, acts as a certification authority, manages peer identities in a peer-to-peer network, and ultimately enhances Bitcoin and similar systems with strong consistency. Our extensive analysis shows that PeerCensus is in a secure state...

  16. Application of mathematical modeling in sustained release delivery systems.

    Science.gov (United States)

    Grassi, Mario; Grassi, Gabriele

    2014-08-01

    This review, presenting as starting point the concept of the mathematical modeling, is aimed at the physical and mathematical description of the most important mechanisms regulating drug delivery from matrix systems. The precise knowledge of the delivery mechanisms allows us to set up powerful mathematical models which, in turn, are essential for the design and optimization of appropriate drug delivery systems. The fundamental mechanisms for drug delivery from matrices are represented by drug diffusion, matrix swelling, matrix erosion, drug dissolution with possible recrystallization (e.g., as in the case of amorphous and nanocrystalline drugs), initial drug distribution inside the matrix, matrix geometry, matrix size distribution (in the case of spherical matrices of different diameter) and osmotic pressure. Depending on matrix characteristics, the above-reported variables may play a different role in drug delivery; thus the mathematical model needs to be built solely on the most relevant mechanisms of the particular matrix considered. Despite the somewhat diffident behavior of the industrial world, in the light of the most recent findings, we believe that mathematical modeling may have a tremendous potential impact in the pharmaceutical field. We do believe that mathematical modeling will be more and more important in the future especially in the light of the rapid advent of personalized medicine, a novel therapeutic approach intended to treat each single patient instead of the 'average' patient.

  17. Sensitivity of the engineered barrier system (EBS) release rate to alternative conceptual models of advective release from waste packages under dripping fractures

    International Nuclear Information System (INIS)

    Lee, J.H.; Atkins, J.E.; McNeish, J.A.; Vallikat, V.

    1996-01-01

    Simulations were conducted to analyze the sensitivity of the engineered barrier system (EBS) release rate to alternative conceptual models of the advective release from waste packages under dripping fractures. The first conceptual model assumed that dripping water directly contacts the waste form inside the 'failed' waste package, and radionuclides are released from the EBS by advection. The second conceptual model assumed that dripping water is diverted around the 'failed' waste package (because of the presence of corrosion products plugging the perforations) and dripping water is prevented from directly contacting the waste form. In the second model, radionuclides were assumed to transport through the perforations by diffusion, and, once outside the waste package, to be released from the EBS by advection. The second model was to incorporate more realism into the EBS release calculations. For the case with the second EBS release model, most radionuclides had significantly lower peak EBS release rates (from at least one to several orders of magnitude) than with the first EBS release model. The impacts of the alternative EBS release models were greater for the radionuclides with a low solubility (or solubility-limited radionuclides) than for the radionuclides with a high solubility (or waste form dissolution-limited radionuclides). The analyses indicated that the EBS release model representing advection through a 'failed' waste package (the first EBS release model) may be too conservative in predicting the EBS performance. One major implication from this sensitivity study was that a 'failed' waste package container with multiple perforations may still be able to perform effectively as an important barrier to radionuclide release. (author)

  18. Effects of sulfate on heavy metal release from iron corrosion scales in drinking water distribution system.

    Science.gov (United States)

    Sun, Huifang; Shi, Baoyou; Yang, Fan; Wang, Dongsheng

    2017-05-01

    Trace heavy metals accumulated in iron corrosion scales within a drinking water distribution system (DWDS) could potentially be released to bulk water and consequently deteriorate the tap water quality. The objective of this study was to identify and evaluate the release of trace heavy metals in DWDS under changing source water conditions. Experimental pipe loops with different iron corrosion scales were set up to simulate the actual DWDS. The effects of sulfate levels on heavy metal release were systemically investigated. Heavy metal releases of Mn, Ni, Cu, Pb, Cr and As could be rapidly triggered by sulfate addition but the releases slowly decreased over time. Heavy metal release was more severe in pipes transporting groundwater (GW) than in pipes transporting surface water (SW). There were strong positive correlations (R 2  > 0.8) between the releases of Fe and Mn, Fe and Ni, Fe and Cu, and Fe and Pb. When switching to higher sulfate water, iron corrosion scales in all pipe loops tended to be more stable (especially in pipes transporting GW), with a larger proportion of stable constituents (mainly Fe 3 O 4 ) and fewer unstable compounds (β-FeOOH, γ-FeOOH, FeCO 3 and amorphous iron oxides). The main functional iron reducing bacteria (IRB) communities were favorable for the formation of Fe 3 O 4 . The transformation of corrosion scales and the growth of sulfate reducing bacteria (SRB) accounted for the gradually reduced heavy metal release with time. The higher metal release in pipes transporting GW could be due to increased Fe 6 (OH) 12 CO 3 content under higher sulfate concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Transfer of accidentally released radionuclides in agricultural systems (TARRAS)

    International Nuclear Information System (INIS)

    Cancio, D.; Maubert, Colle; Rauret, G.; Grandison, A.S.

    1993-01-01

    The aim of this project is to contribute to the reliability of radiological assessment methods and establish a scientific base for the design of post-accident countermeasures. Three main aspects are considered in this project: A simulated accidental source term is used and the behaviour of aerosol deposits containing Sr, Cs and Ag isotopes are followed in some European soil-crop systems; the modification of radionuclide transfer rates through the food chain by well established food processing techniques is studied for Sr, Cs, Co and Ru; the project includes a study on the specific mediterranean diet and transfer data that are compared with currently used generic parameters. Seven contributions of the project for the reporting period are presented. (R.P.) 11 figs., 12 tabs

  20. Harmonic oscillations, chaos and synchronization in systems consisting of Van der Pol oscillator coupled to a linear oscillator

    International Nuclear Information System (INIS)

    Woafo, P.

    1999-12-01

    This paper deals with the dynamics of a model describing systems consisting of the classical Van der Pol oscillator coupled gyroscopically to a linear oscillator. Both the forced and autonomous cases are considered. Harmonic response is investigated along with its stability boundaries. Condition for quenching phenomena in the autonomous case is derived. Neimark bifurcation is observed and it is found that our model shows period doubling and period-m sudden transitions to chaos. Synchronization of two and more systems in their chaotic regime is presented. (author)

  1. A core concept for the self-consistent nuclear energy system based on the promising future technology

    International Nuclear Information System (INIS)

    Arie, K.; Suzuki, M.; Kawashima, M.; Igashira, M.; Shimizu, A.; Fujii-e, Y.

    1995-01-01

    Feasibility of FP burning while maintaining fuel breeding capability for the Self-Consistent Nuclear Energy System is evaluated through neutron balance and a fast reactor core. It is shown that all radioactive FPs produced by itself can be burnt by a fast reactor while maintaining breeding capability, assuming separation of radioactive FP and stable FP isotopes. Assuming that the recovery system of fuel and FPs to be burnt is based on a pyro-chemical process, the major long-lived FPs of I, Pd, Tc, Sn, Se can be burnt with keeping breeding capability by suitability arranging materials in the fast reactor core. (Author)

  2. Ammonium release from a blanket peatland into headwater stream systems

    International Nuclear Information System (INIS)

    Daniels, S.M.; Evans, M.G.; Agnew, C.T.; Allott, T.E.H.

    2012-01-01

    Hydrochemical sampling of South Pennine (UK) headwater streams draining eroded upland peatlands demonstrates these systems are nitrogen saturated, with significant leaching of dissolved inorganic nitrogen (DIN), particularly ammonium, during both stormflow and baseflow conditions. DIN leaching at sub-catchment scale is controlled by geomorphological context; in catchments with low gully densities ammonium leaching dominates whereas highly gullied catchments leach ammonium and nitrate since lower water tables and increased aeration encourages nitrification. Stormflow flux calculations indicate that: approximately equivalent amounts of nitrate are deposited and exported; ammonium export significantly exceeds atmospheric inputs. This suggests two ammonium sources: high atmospheric loadings; and mineralisation of organic nitrogen stored in peat. Downstream trends indicate rapid transformation of leached ammonium into nitrate. It is important that low-order headwater streams are adequately considered when assessing impacts of atmospheric loads on the hydrochemistry of stream networks, especially with respect to erosion, climate change and reduced precipitation. - Highlights: ► Headwaters draining eroded South Pennine (UK) peatlands are nitrogen saturated. ► Ammonium and nitrate leaching arises from aeration due to lower water tables. ► Nitrate deposition equals export during storms; ammonium export exceeds input. ► Ammonia input from high atmospheric loading and mineralisation of organic nitrogen. ► Downstream nitrogen trends indicate rapid transformation of ammonium into nitrate. - Inorganic nitrogen leaching from South Pennine peatlands is dominated by ammonium that is rapidly transformed within-streams to nitrate.

  3. A New Drug Release Method in Early Development of Transdermal Drug Delivery Systems

    Directory of Open Access Journals (Sweden)

    Bing Cai

    2012-01-01

    Full Text Available In vitro drug release tests are a widely used tool to measure the variance between transdermal product performances and required by many authorities. However, the result cannot provide a good estimation of the in vivo drug release. In the present work, a new method for measuring drug release from patches has been explored and compared with the conventional USP apparatus 2 and 5 methods. Durogesic patches, here used as a model patch, were placed on synthetic skin simulator and three moisture levels (29, 57, 198 μL cm−2 were evaluated. The synthetic skin simulators were collected after 1, 2, 3, 4, 6, and 24 hours and extracted with pH 1.0 hydrochloric acid solution. The drug concentrations in the extractions were measured by isocratic reverse phase high-pressure liquid chromatography. The results showed that, with the increasing moisture level on the synthetic skin simulator, the drug release rate increased. In comparison with the conventional USP method, the drug release results performed by the new method were in more correlation to the release rate claimed in the product label. This new method could help to differentiate the drug release rates among assorted formulations of transdermal drug delivery systems in the early stage of development.

  4. Active and reactive power sharing and frequency restoration in a distributed power system consisting of two UPS units

    Energy Technology Data Exchange (ETDEWEB)

    Parlak, Koray Sener; Oezdemir, Mehmet [Dept. of Electrical and Electronic Engineering, Firat University, Elazig, 23119 (Turkey); Aydemir, M. Timur [Dept. of Electrical and Electronic Engineering, Gazi University, Maltepe-Ankara 06570 (Turkey)

    2009-06-15

    A distributed power system consisting of two uninterrupted power supplies (UPS) is investigated in this paper. Parallel operation of the two sources increases the established power rating of the system. One of the sources can supply the system even when the other system is disconnected due to some faults, and this is an important feature. The control algorithm makes sure that the total load is shared between the supplies in accordance with their rated power levels, and the frequency of the supplies are restored to the rated values after the transitions. As the UPSs operate at an optimum power level, losses and faults due to overloading are prevented. The units safely operate without any means of communication between each other. The focus of the work is on the inverter stages of the UPSs. Simulations performed in Matlab Simulink environment have been verified with experimental work via DS1103 controller card. (author)

  5. Gonadotropin-releasing hormone immunoreactivity in the adult and fetal human olfactory system.

    Science.gov (United States)

    Kim, K H; Patel, L; Tobet, S A; King, J C; Rubin, B S; Stopa, E G

    1999-05-01

    Studies in fetal brain tissue of rodents, nonhuman primates and birds have demonstrated that cells containing gonadotropin-releasing hormone (GnRH) migrate from the olfactory placode across the nasal septum into the forebrain. The purpose of this study was to examine GnRH neurons in components of the adult and fetal human olfactory system. In the adult human brain (n=4), immunoreactive GnRH was evident within diffusely scattered cell bodies and processes in the olfactory bulb, olfactory nerve, olfactory cortex, and nervus terminalis located on the anterior surface of the gyrus rectus. GnRH-immunoreactive structures showed a similar distribution in 20-week human fetal brains (n=2), indicating that the migration of GnRH neurons is complete at this time. In 10-11-week fetal brains (n=2), more cells were noted in the nasal cavity than in the brain. Our data are consistent with observations made in other species, confirming olfactory derivation and migration of GnRH neurons into the brain from the olfactory placode. Copyright 1999 Elsevier Science B.V.

  6. Monitoring and diagnostic system of fission product transport and release in nuclear power plants

    International Nuclear Information System (INIS)

    Kodaira, H.; Kondo, S.; Togo, Y.

    1983-01-01

    A monitoring and diagnostic system (MADS) of fission product (FP) transport and release in nuclear power plants (NPPs) is proposed and the conceptual design for MADS is studied. A MADS can be described in the most general way as a computer-based information processing system which takes in plant data, processes it and displays the results to the NPP's operating crew. A major concern for MADS is, however, not to evaluate general plant dynamics, but to monitor the distribution of whole radioactive materials such as FP, and to diagnose the plant state in the view of FP transport during the NPP's lifetime. Several functions demanded of MADS are: (a) during normal operation, to certify the fuel integrity and the effectiveness of the purification systems, (b) in an unusual event, to identify the event and to monitor the amount of FP release with accuracy, and (c) in case of a rare occurrence, to estimate the maximum potential release

  7. Systems biology definition of the core proteome of metabolism and expression is consistent with high-throughput data

    DEFF Research Database (Denmark)

    Yang, Laurence; Tan, Justin; O'Brien, Edward J.

    2015-01-01

    based on proteomics data. This systems biology core proteome includes 212 genes not found in previous comparative genomics-based core proteome definitions, accounts for 65% of known essential genes in E. coli, and has 78% gene function overlap with minimal genomes (Buchnera aphidicola and Mycoplasma......Finding the minimal set of gene functions needed to sustain life is of both fundamental and practical importance. Minimal gene lists have been proposed by using comparative genomics-based core proteome definitions. A definition of a core proteome that is supported by empirical data, is understood...... at the systems-level, and provides a basis for computing essential cell functions is lacking. Here, we use a systems biology-based genome-scale model of metabolism and expression to define a functional core proteome consisting of 356 gene products, accounting for 44% of the Escherichia coli proteome by mass...

  8. Multi-Time Scale Model Order Reduction and Stability Consistency Certification of Inverter-Interfaced DG System in AC Microgrid

    Directory of Open Access Journals (Sweden)

    Xiaoxiao Meng

    2018-01-01

    Full Text Available AC microgrid mainly comprise inverter-interfaced distributed generators (IIDGs, which are nonlinear complex systems with multiple time scales, including frequency control, time delay measurements, and electromagnetic transients. The droop control-based IIDG in an AC microgrid is selected as the research object in this study, which comprises power droop controller, voltage- and current-loop controllers, and filter and line. The multi-time scale characteristics of the detailed IIDG model are divided based on singular perturbation theory. In addition, the IIDG model order is reduced by neglecting the system fast dynamics. The static and transient stability consistency of the IIDG model order reduction are demonstrated by extracting features of the IIDG small signal model and using the quadratic approximation method of the stability region boundary, respectively. The dynamic response consistencies of the IIDG model order reduction are evaluated using the frequency, damping and amplitude features extracted by the Prony transformation. Results are applicable to provide a simplified model for the dynamic characteristic analysis of IIDG systems in AC microgrid. The accuracy of the proposed method is verified by using the eigenvalue comparison, the transient stability index comparison and the dynamic time-domain simulation.

  9. An experimental system for release simulation of internal stores in a supersonic wind tunnel

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2017-02-01

    Full Text Available Aerodynamic parameters obtained from separation experiments of internal stores in a wind tunnel are significant in aircraft designs. Accurate wind tunnel tests can help to improve the release stability of the stores and in-flight safety of the aircrafts in supersonic environments. A simulative system for free drop experiments of internal stores based on a practical project is provided in this paper. The system contains a store release mechanism, a control system and an attitude measurement system. The release mechanism adopts a six-bar linkage driven by a cylinder, which ensures the release stability. The structure and initial aerodynamic parameters of the stores are also designed and adjusted. A high speed vision measurement system for high speed rolling targets is utilized to measure the pose parameters of the internal store models and an optimizing method for the coordinates of markers is presented based on a priori model. The experimental results show excellent repeatability of the system, and indicate that the position measurement precision is less than 0.13 mm, and the attitude measurement precision for pitch and yaw angles is less than 0.126°, satisfying the requirements of practical wind tunnel tests. A separation experiment for the internal stores is also conducted in the FL-3 wind tunnel of China Aerodynamics Research Institute.

  10. Construction of a controlled-release delivery system for pesticides using biodegradable PLA-based microcapsules.

    Science.gov (United States)

    Liu, Baoxia; Wang, Yan; Yang, Fei; Wang, Xing; Shen, Hong; Cui, Haixin; Wu, Decheng

    2016-08-01

    Conventional pesticides usually need to be used in more than recommended dosages due to their loss and degradation, which results in a large waste of resources and serious environmental pollution. Encapsulation of pesticides in biodegradable carriers is a feasible approach to develop environment-friendly and efficient controlled-release delivery system. In this work, we fabricated three kinds of polylactic acid (PLA) carriers including microspheres, microcapsules, and porous microcapsules for controlled delivery of Lambda-Cyhalothrin (LC) via premix membrane emulsification (PME). The microcapsule delivery system had better water dispersion than the other two systems. Various microcapsules with a high LC contents as much as 40% and tunable sizes from 0.68 to 4.6μm were constructed by manipulating the process parameters. Compared with LC technical and commercial microcapsule formulation, the microcapsule systems showed a significantly sustained release of LC for a longer period. The LC release triggered by LC diffusion and matrix degradation could be optimally regulated by tuning LC contents and particle sizes of the microcapsules. This multi-regulated release capability is of great significance to achieve the precisely controlled release of pesticides. A preliminary bioassay against plutella xylostella revealed that 0.68μm LC-loaded microcapsules with good UV and thermal stability exhibited an activity similar to a commercial microcapsule formulation. These results demonstrated such an aqueous microcapsule delivery system had a great potential to be further explored for developing an effective and environmentally friendly pesticide-release formulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Breeding system and bumblebee drone pollination of an explosively pollen-releasing plant, Meliosma tenuis (Sabiaceae).

    Science.gov (United States)

    Wong Sato, A A; Kato, M

    2018-05-01

    Explosive pollen release is a mechanism used by some angiosperms that serves to attach pollen to a pollinator's body. It is usually adopted by species with zygomorphic tubular flowers and pollinated by birds and bees. The tree genus Meliosma (Sabiaceae, Proteales) has unique disc-like flowers that are externally actinomorphic, but internally zygomorphic, and release pollen explosively. To elucidate the adaptive significance of explosive pollen release, we observed flowering behaviour, the breeding system and pollinator visits to flowers of the Japanese species Meliosma tenuis in a temperate forest. Flowers bloomed in June and were nectariferous and protandrous. Explosive pollen release was triggered by slight tactile stimuli to anther filaments or staminodes in male-stage flowers. Because pollen cannot come into contact with the pistils enclosed by staminodes, M. tenuis is functionally protandrous. Artificial pollination treatments revealed that M. tenuis is allogamous. The dominant flower visitors were nectar-seeking drones of the bumblebee species Bombus ardens (Apidae). The drones' behaviour, pollen attachment on their bodies and fruit set of visit-restricted flowers suggest that they are the only agent triggering the explosive pollen release mechanism, and are the main pollinator of M. tenuis. The finding that bumblebee workers rarely visit these flowers suggests that the explosive pollen release has another function, namely to discourage pollen-harvesting bumblebee workers. © 2018 German Society for Plant Sciences and The Royal Botanical Society of the Netherlands.

  12. Performance of hybrid quad generation system consisting of solid oxide fuel cell system and absorption heat pump

    DEFF Research Database (Denmark)

    Cachorro, Irene Albacete; Daraban, Iulia Maria; Lainé, Guillaume

    2013-01-01

    . The heat pump is a heat driven system and is running with the heat recovered by a heat exchanger from the exhausted gases from SOFC. The working fluid pair is NH3-H2O and is driven in two evaporators which are working at two different pressures. Thus, the heat pump will operate at tree pressure level...... with natural gas. The natural gas is first converted to a mixture of H2 and CO which feed the anode after a preheating step. The cathode is supplied with preheated air and gives, as output, electrical energy. The anode output is the exhaust gas which represents the thermal energy reservoir for heating...

  13. Oral controlled release drug delivery system and Characterization of oral tablets; A review

    OpenAIRE

    Muhammad Zaman; Junaid Qureshi; Hira Ejaz; Rai Muhammad Sarfraz; Hafeez ullah Khan; Fazal Rehman Sajid; Muhammad Shafiq ur Rehman

    2016-01-01

    Oral route of drug administration is considered as the safest and easiest route of drug administration. Control release drug delivery system is the emerging trend in the pharmaceuticals and the oral route is most suitable for such kind of drug delivery system. Oral route is more convenient for It all age group including both pediatric and geriatrics. There are various systems which are adopted to deliver drug in a controlled manner to different target sites through oral route. It includes dif...

  14. [Construction of multiple drug release system based on components of traditional Chinese medicine].

    Science.gov (United States)

    Liu, Dan; Jia, Xiaobin; Yu, Danhong; Zhang, Zhenhai; Sun, E

    2012-08-01

    With the development of the modernization drive of traditional Chinese medicine (TCM) preparations, new-type TCM dosage forms research have become a hot spot in the field. Because of complexity of TCM components as well as uncertainty of material base, there is still not a scientific system for modern TCM dosage forms so far. Modern TCM preparations inevitably take the nature of the multi-component and the general function characteristics of multi-link and multi-target into account. The author suggests building a multiple drug release system for TCM using diverse preparation techniques and drug release methods at levels on the basis the nature and function characteristics of TCM components. This essay expounds elaborates the ideas to build the multiple traditional Chinese medicine release system, theoretical basis, preparation techniques and assessment system, current problems and solutions, in order to build a multiple TCM release system with a view of enhancing the bioavailability of TCM components and provide a new form for TCM preparations.

  15. Time-dependent restricted-active-space self-consistent-field theory for bosonic many-body systems

    International Nuclear Information System (INIS)

    Lévêque, Camille; Madsen, Lars Bojer

    2017-01-01

    We develop an ab initio time-dependent wavefunction based theory for the description of a many-body system of cold interacting bosons. Like the multi-configurational time-dependent Hartree method for bosons (MCTDHB), the theory is based on a configurational interaction Ansatz for the many-body wavefunction with time-dependent self-consistent-field orbitals. The theory generalizes the MCTDHB method by incorporating restrictions on the active space of the orbital excitations. The restrictions are specified based on the physical situation at hand. The equations of motion of this time-dependent restricted-active-space self-consistent-field (TD-RASSCF) theory are derived. The similarity between the formal development of the theory for bosons and fermions is discussed. The restrictions on the active space allow the theory to be evaluated under conditions where other wavefunction based methods due to exponential scaling in the numerical effort cannot, and to clearly identify the excitations that are important for an accurate description, significantly beyond the mean-field approach. For ground state calculations we find it to be important to allow a few particles to have the freedom to move in many orbitals, an insight facilitated by the flexibility of the restricted-active-space Ansatz . Moreover, we find that a high accuracy can be obtained by including only even excitations in the many-body self-consistent-field wavefunction. Time-dependent simulations of harmonically trapped bosons subject to a quenching of their noncontact interaction, show failure of the mean-field Gross-Pitaevskii approach within a fraction of a harmonic oscillation period. The TD-RASSCF theory remains accurate at much reduced computational cost compared to the MCTDHB method. Exploring the effect of changes of the restricted-active-space allows us to identify that even self-consistent-field excitations are mainly responsible for the accuracy of the method. (paper)

  16. Mitigation of strontium and ruthenium release in the CANDU primary heat transport system

    Energy Technology Data Exchange (ETDEWEB)

    McFarlane, J

    1998-03-01

    In certain severe accident scenarios, low-volatility fission products can appear to contribute significantly to dose, if treated with undue conservatism. Hence a survey was performed, to see if factors that may mitigate release of strontium and ruthenium could be incorporated into safety analyses, to cover parameters such as location in the fuel matrix under normal operating conditions, release from fuel, transport and deposition in the primary heat transport system and chemistry. In addition chemical equilibrium calculations were performed to investigate the volatility of strontium and ruthenium in the presence of uranium and important fission products. Strontium is very soluble in the U0{sub 2} fuel, up to 12 atom %, and hence release is improbable, particularly under oxidizing conditions until volatilization of the fuel matrix itself occurs. Ruthenium, however, can be released at low temperatures, but only under oxidizing conditions. These may occur during a fuel-handling accident or as a result of an end-fitting failure. Under these conditions, the primary heat transport system cannot be credited for retention. The volatile form of ruthenium, RuO{sub 4}(g), is thermally unstable above 381 K and decomposes to RuO{sub 2}(s) and O{sub 2}(g) upon contact with surfaces, a factor that is likely to minimize the release of ruthenium into the environment. (author)

  17. Mitigation of strontium and ruthenium release in the CANDU primary heat transport system

    International Nuclear Information System (INIS)

    McFarlane, J.

    1998-03-01

    In certain severe accident scenarios, low-volatility fission products can appear to contribute significantly to dose, if treated with undue conservatism. Hence a survey was performed, to see if factors that may mitigate release of strontium and ruthenium could be incorporated into safety analyses, to cover parameters such as location in the fuel matrix under normal operating conditions, release from fuel, transport and deposition in the primary heat transport system and chemistry. In addition chemical equilibrium calculations were performed to investigate the volatility of strontium and ruthenium in the presence of uranium and important fission products. Strontium is very soluble in the U0 2 fuel, up to 12 atom %, and hence release is improbable, particularly under oxidizing conditions until volatilization of the fuel matrix itself occurs. Ruthenium, however, can be released at low temperatures, but only under oxidizing conditions. These may occur during a fuel-handling accident or as a result of an end-fitting failure. Under these conditions, the primary heat transport system cannot be credited for retention. The volatile form of ruthenium, RuO 4 (g), is thermally unstable above 381 K and decomposes to RuO 2 (s) and O 2 (g) upon contact with surfaces, a factor that is likely to minimize the release of ruthenium into the environment. (author)

  18. Consequences of the release of chemical pollutants on the transfers of radiioactive products in aquatic systems

    International Nuclear Information System (INIS)

    Bittel, R.

    1975-01-01

    With the increasing rate of industrial activities, aquatic systems undergo, more and more frequently, the accumulation of chemical and radioactive wastes released separatly or associated in the same discharge. An attempt is made to evaluate the consequence of the association of pollutants on the transfers of neutron activation radionuclides. Emphasis is given to heavy metal pollution and complexing agents [fr

  19. Pharmacokinetics and Pharmacodynamics of Tamsulosin in its Modified-Release and Oral Controlled Absorption System Formulations

    NARCIS (Netherlands)

    Franco-Salinas, Gabriela; de La Rosette, Jean J. M. C. H.; Michel, Martin C.

    2010-01-01

    Tamsulosin is an alpha(1)-adrenoceptor antagonist used for the treatment of lower urinary tract symptoms that are suggestive of benign prostatic hyperplasia. It is mostly used in a modified-release (M R) Formulation. but an oral controlled absorption system (OCAS) and a 'without-water' tablet

  20. Dynamics of controlled release systems based on water-in-water emulsions: A general theory

    NARCIS (Netherlands)

    Sagis, L.M.C.

    2008-01-01

    Phase-separated biopolymer solutions, and aqueous dispersions of hydrogel beads, liposomes, polymersomes, aqueous polymer microcapsules, and colloidosomes are all examples of water-in-water emulsions. These systems can be used for encapsulation and controlled release purposes, in for example food or

  1. Synthesis of hydrogels of alginate for system controlled release of progesterone

    International Nuclear Information System (INIS)

    Abreu, Marlon de F.; Rodriguez, Ruben J.S.; Silva, Ester C.C. da; Barreto, Gabriela N.S.

    2015-01-01

    The chemical modifications of natural polymers like alginate, has allowed the development of new formulations for controlled release systems. In this work we report the synthesis of a derivative of the amidic alginate with alkyl chain. The polymer was characterized by spectroscopic techniques: Nuclear Magnetic Resonance and Fourier Transform Infrared. (author)

  2. Effectiveness of slow-release systems in CD40 agonistic antibody immunotherapy of cancer

    NARCIS (Netherlands)

    Fransen, Marieke F.; Cordfunke, Robert A.; Sluijter, Marjolein; Van Steenbergen, Mies J.; Drijfhout, Jan W.; Ossendorp, Ferry; Hennink, Wim E.; Melief, Cornelis J M

    2014-01-01

    Slow-release delivery has great potential for specifically targeting immune-modulating agents into the tumor-draining area. In prior work we showed that local treatment of slowly delivered anti-CD40 antibody induced robust anti-tumor CD8+ T cell responses without systemic toxicity. We now report on

  3. An Injectable System for Local and Sustained Release of Antimicrobial Agents in the Periodontal Pocket.

    Science.gov (United States)

    Morelli, Laura; Cappelluti, Martino Alfredo; Ricotti, Leonardo; Lenardi, Cristina; Gerges, Irini

    2017-08-01

    Periodontitis treatments usually require local administration of antimicrobial drugs with the aim to reduce the bacterial load inside the periodontal pocket. Effective pharmaceutical treatments may require sustained local drug release for several days in the site of interest. Currently available solutions are still not able to fulfill the clinical need for high-quality treatments, mainly in terms of release profiles and patients' comfort. This work aims to fill this gap through the development of an in situ gelling system, capable to achieve controlled and sustained release of antimicrobial agents for medium-to-long-term treatments. The system is composed of micrometer-sized β-cyclodextrin-based hydrogel (bCD-Jef-MPs), featured by a strong hydrophilic character, suspended in a synthetic block-co-polymer solution (Poloxamer 407), which is capable to undergo rapid thermally induced sol-gel phase transition at body temperature. The chemical structure of bCD-Jef-MPs was confirmed by cross-correlating data from Fourier transform infrared (FTIR) spectroscopy, swelling test, and degradation kinetics. The thermally induced sol-gel phase transition is demonstrated by rheometric tests. The effectiveness of the described system to achieve sustained release of antimicrobial agents is demonstrated in vitro, using chlorhexidine digluconate as a drug model. The results achieved in this work disclose the potential of the mentioned system in effectively treating periodontitis lesions. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Timing of insertion of levonorgestrel-releasing intrauterine system : a randomised controlled trial

    NARCIS (Netherlands)

    van der Heijden, Pahh; Geomini, Pmaj; Herman, M C; Veersema, S; Bongers, M Y

    OBJECTIVE: The objective was to assess whether patient-perceived pain during the insertion of the levonorgestrel-releasing intrauterine system (LNG-IUS) depends on the timing during the menstrual cycle. DESIGN: A stratified two-armed non-inferiority randomised controlled trial. SETTING: Large

  5. A SELF-CONSISTENT MODEL OF THE CIRCUMSTELLAR DEBRIS CREATED BY A GIANT HYPERVELOCITY IMPACT IN THE HD 172555 SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, B. C.; Melosh, H. J. [Department of Physics, Purdue University, 525 Northwestern Avenue, West Lafayette, IN 47907 (United States); Lisse, C. M. [JHU-APL, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Chen, C. H. [STScI, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Wyatt, M. C. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Thebault, P. [LESIA, Observatoire de Paris, F-92195 Meudon Principal Cedex (France); Henning, W. G. [NASA Goddard Space Flight Center, 8800 Greenbelt Road, Greenbelt, MD 20771 (United States); Gaidos, E. [Department of Geology and Geophysics, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Elkins-Tanton, L. T. [Department of Terrestrial Magnetism, Carnegie Institution for Science, Washington, DC 20015 (United States); Bridges, J. C. [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom); Morlok, A., E-mail: johns477@purdue.edu [Department of Physical Sciences, Open University, Walton Hall, Milton Keynes MK7 6AA (United Kingdom)

    2012-12-10

    Spectral modeling of the large infrared excess in the Spitzer IRS spectra of HD 172555 suggests that there is more than 10{sup 19} kg of submicron dust in the system. Using physical arguments and constraints from observations, we rule out the possibility of the infrared excess being created by a magma ocean planet or a circumplanetary disk or torus. We show that the infrared excess is consistent with a circumstellar debris disk or torus, located at {approx}6 AU, that was created by a planetary scale hypervelocity impact. We find that radiation pressure should remove submicron dust from the debris disk in less than one year. However, the system's mid-infrared photometric flux, dominated by submicron grains, has been stable within 4% over the last 27 years, from the Infrared Astronomical Satellite (1983) to WISE (2010). Our new spectral modeling work and calculations of the radiation pressure on fine dust in HD 172555 provide a self-consistent explanation for this apparent contradiction. We also explore the unconfirmed claim that {approx}10{sup 47} molecules of SiO vapor are needed to explain an emission feature at {approx}8 {mu}m in the Spitzer IRS spectrum of HD 172555. We find that unless there are {approx}10{sup 48} atoms or 0.05 M{sub Circled-Plus} of atomic Si and O vapor in the system, SiO vapor should be destroyed by photo-dissociation in less than 0.2 years. We argue that a second plausible explanation for the {approx}8 {mu}m feature can be emission from solid SiO, which naturally occurs in submicron silicate ''smokes'' created by quickly condensing vaporized silicate.

  6. A SELF-CONSISTENT MODEL OF THE CIRCUMSTELLAR DEBRIS CREATED BY A GIANT HYPERVELOCITY IMPACT IN THE HD 172555 SYSTEM

    International Nuclear Information System (INIS)

    Johnson, B. C.; Melosh, H. J.; Lisse, C. M.; Chen, C. H.; Wyatt, M. C.; Thebault, P.; Henning, W. G.; Gaidos, E.; Elkins-Tanton, L. T.; Bridges, J. C.; Morlok, A.

    2012-01-01

    Spectral modeling of the large infrared excess in the Spitzer IRS spectra of HD 172555 suggests that there is more than 10 19 kg of submicron dust in the system. Using physical arguments and constraints from observations, we rule out the possibility of the infrared excess being created by a magma ocean planet or a circumplanetary disk or torus. We show that the infrared excess is consistent with a circumstellar debris disk or torus, located at ∼6 AU, that was created by a planetary scale hypervelocity impact. We find that radiation pressure should remove submicron dust from the debris disk in less than one year. However, the system's mid-infrared photometric flux, dominated by submicron grains, has been stable within 4% over the last 27 years, from the Infrared Astronomical Satellite (1983) to WISE (2010). Our new spectral modeling work and calculations of the radiation pressure on fine dust in HD 172555 provide a self-consistent explanation for this apparent contradiction. We also explore the unconfirmed claim that ∼10 47 molecules of SiO vapor are needed to explain an emission feature at ∼8 μm in the Spitzer IRS spectrum of HD 172555. We find that unless there are ∼10 48 atoms or 0.05 M ⊕ of atomic Si and O vapor in the system, SiO vapor should be destroyed by photo-dissociation in less than 0.2 years. We argue that a second plausible explanation for the ∼8 μm feature can be emission from solid SiO, which naturally occurs in submicron silicate ''smokes'' created by quickly condensing vaporized silicate.

  7. Systems biology definition of the core proteome of metabolism and expression is consistent with high-throughput data.

    Science.gov (United States)

    Yang, Laurence; Tan, Justin; O'Brien, Edward J; Monk, Jonathan M; Kim, Donghyuk; Li, Howard J; Charusanti, Pep; Ebrahim, Ali; Lloyd, Colton J; Yurkovich, James T; Du, Bin; Dräger, Andreas; Thomas, Alex; Sun, Yuekai; Saunders, Michael A; Palsson, Bernhard O

    2015-08-25

    Finding the minimal set of gene functions needed to sustain life is of both fundamental and practical importance. Minimal gene lists have been proposed by using comparative genomics-based core proteome definitions. A definition of a core proteome that is supported by empirical data, is understood at the systems-level, and provides a basis for computing essential cell functions is lacking. Here, we use a systems biology-based genome-scale model of metabolism and expression to define a functional core proteome consisting of 356 gene products, accounting for 44% of the Escherichia coli proteome by mass based on proteomics data. This systems biology core proteome includes 212 genes not found in previous comparative genomics-based core proteome definitions, accounts for 65% of known essential genes in E. coli, and has 78% gene function overlap with minimal genomes (Buchnera aphidicola and Mycoplasma genitalium). Based on transcriptomics data across environmental and genetic backgrounds, the systems biology core proteome is significantly enriched in nondifferentially expressed genes and depleted in differentially expressed genes. Compared with the noncore, core gene expression levels are also similar across genetic backgrounds (two times higher Spearman rank correlation) and exhibit significantly more complex transcriptional and posttranscriptional regulatory features (40% more transcription start sites per gene, 22% longer 5'UTR). Thus, genome-scale systems biology approaches rigorously identify a functional core proteome needed to support growth. This framework, validated by using high-throughput datasets, facilitates a mechanistic understanding of systems-level core proteome function through in silico models; it de facto defines a paleome.

  8. pH- and thermo-responsive microcontainers as potential drug delivery systems: Morphological characteristic, release and cytotoxicity studies.

    Science.gov (United States)

    Efthimiadou, Eleni K; Tapeinos, Christos; Tziveleka, Leto-Aikaterini; Boukos, Nikos; Kordas, George

    2014-04-01

    Polymeric pH- and thermo-sensitive microcontainers (MCs) were developed as a potential drug delivery system for cancer therapy. It is well known that cancer cells exhibit notable characteristics such as acidic pH due to glycolytic cycle and higher temperature due to their higher proliferation rate. Based on these characteristics, we constructed a dual pH- and thermo-sensitive material for specific drug release on the pathological tissue. The MC's fabrication is based on a two-step procedure, in which, the first step involves the core synthesis and the second one is related to the shell formation. The core consists of poly(methyl methacrylate (PMMA), while the shell consists of PMMA, poly(isopropylacrylamide), poly(acrylic acid) and poly(divinylbenzene). Three different types of MCs were synthesized based on the seed polymerization method. The synthesized MCs were characterized structurally by Fourier transform infrared and morphologically by scanning electron microscopy. Dynamic light scattering was also used to study their behavior in aqueous solution under different pH and temperature conditions. For the loading and release study, the anthracycline drug daunorubicin (DNR) was used as a model drug, and its release properties were evaluated under different pH and thermo-conditions. Cytotoxicity studies were also carried out against MCF-7 breast cancer and 3T3 mouse embryonic fibroblast cells. According to our results, the synthesized microcontainers present desired pH and thermo behavior and can be applied in drug delivery systems. It is worth mentioning that the synthesized microcontainers which incorporated the drug DNR exhibit higher toxicity than the free drug. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Poly lactic acid based injectable delivery systems for controlled release of a model protein, lysozyme.

    Science.gov (United States)

    Al-Tahami, Khaled; Meyer, Amanda; Singh, Jagdish

    2006-02-01

    The objective of this study was to evaluate the critical formulation parameters (i.e., polymer concentration, polymer molecular weight, and solvent nature) affecting the controlled delivery of a model protein, lysozyme, from injectable polymeric implants. The conformational stability and biological activity of the released lysozyme were also investigated. Three formulations containing 10%, 20%, and 30% (w/v) poly lactic acid (PLA) in triacetin were investigated. It was found that increasing polymer concentration in the formulations led to a lower burst effect and a slower release rate. Formulation with a high molecular weight polymer showed a greater burst effect as compared to those containing low molecular weight. Conformational stability and biological activity of released samples were studied by differential scanning calorimeter and enzyme activity assay, respectively. The released samples had significantly (P solution kept at same conditions). Increasing polymer concentration increased both the conformational stability and the biological activity of released lysozyme. In conclusion, phase sensitive polymer-based delivery systems were able to deliver a model protein, lysozyme, in a conformationally stable and biologically active form at a controlled rate over an extended period.

  10. On-Line Fission Gas Release Monitoring System in the High Flux Reactor Petten

    International Nuclear Information System (INIS)

    Laurie, M.; Fuetterer, M. A.; Appelman, K.H.; Lapetite, J.-M.; Marmier, A.; Knol, S.; Best, J.

    2013-06-01

    For HTR fuel irradiation tests in the HFR Petten a specific installation was designed and installed dubbed the 'Sweep Loop Facility' (SLF). The SLF is tasked with three functions, namely temperature control by gas mixture technique, surveillance of safety parameters (temperature, pressure, radioactivity etc.) and analysis of fission gas release for three individual capsules in two separate experimental rigs. The SLF enables continuous and independent surveillance of all gas circuits. The release of volatile fission products (FP) from the in-pile experiments is monitored by continuous gas purging. The fractional release of these FP, defined as the ratio between release rate of a gaseous fission isotope (measured) to its instantaneous birth rate (calculated), is a licensing-relevant test for HTR fuel. The developed gamma spectrometry station allows for higher measurement frequencies, thus enabling follow-up of rapid and massive release transients. The designed stand-alone system was tested and fully used through the final irradiation period of the HFR-EU1 experiment which was terminated on 18 February 2010. Its robustness allowed the set up to be used as extra safety instrumentation. This paper describes the gas activity measurement technique based on HPGe gamma spectrometry and illustrates how qualitative and quantitative analysis of volatile FP can be performed on-line. (authors)

  11. The OCaml system release 4.04: Documentation and user's manual

    OpenAIRE

    Leroy, Xavier; Doligez, Damien; Frisch, Alain; Garrigue, Jacques; Rémy, Didier; Vouillon, Jérôme

    2016-01-01

    This manual documents the release 4.04 of the OCaml system. It is organized as follows. Part I, "An introduction to OCaml", gives an overview of the language. Part II, "The OCaml language", is the reference description of the language. Part III, "The OCaml tools", documents the compilers, toplevel system, and programming utilities. Part IV, "The OCaml library", describes the modules provided in the standard library.

  12. The OCaml system release 4.02: Documentation and user's manual

    OpenAIRE

    Leroy, Xavier; Doligez, Damien; Frisch, Alain; Garrigue, Jacques; Rémy, Didier; Vouillon, Jérôme

    2014-01-01

    This manual documents the release 4.02 of the OCaml system. It is organized as follows. Part I, "An introduction to OCaml", gives an overview of the language. Part II, "The OCaml language", is the reference description of the language. Part III, "The OCaml tools", documents the compilers, toplevel system, and programming utilities. Part IV, "The OCaml library", describes the modules provided in the standard library.

  13. The OCaml system release 4.06: Documentation and user's manual

    OpenAIRE

    Leroy , Xavier; Doligez , Damien; Frisch , Alain; Garrigue , Jacques; Rémy , Didier; Vouillon , Jérôme

    2017-01-01

    This manual documents the release 4.06 of the OCaml system. It is organized as follows. Part I, "An introduction to OCaml", gives an overview of the language. Part II, "The OCaml language", is the reference description of the language. Part III, "The OCaml tools", documents the compilers, toplevel system, and programming utilities. Part IV, "The OCaml library", describes the modules provided in the standard library.

  14. A self-consistent field study of diblock copolymer/charged particle system morphologies for nanofiltration membranes

    International Nuclear Information System (INIS)

    Zhang, Bo; Ye, Xianggui; Edwards, Brian J.

    2013-01-01

    A combination of self-consistent field theory and density functional theory was used to examine the stable, 3-dimensional equilibrium morphologies formed by diblock copolymers with a tethered nanoparticle attached either between the two blocks or at the end of one of the blocks. Both neutral and interacting particles were examined, with and without favorable/unfavorable energetic potentials between the particles and the block segments. The phase diagrams of the various systems were constructed, allowing the identification of three types of ordered mesophases composed of lamellae, hexagonally packed cylinders, and spheroids. In particular, we examined the conditions under which the mesophases could be generated wherein the tethered particles were primarily located within the interface between the two blocks of the copolymer. Key factors influencing these properties were determined to be the particle position along the diblock chain, the interaction potentials of the blocks and particles, the block copolymer composition, and molecular weight of the copolymer

  15. An eddy-permitting, dynamically consistent adjoint-based assimilation system for the tropical Pacific: Hindcast experiments in 2000

    KAUST Repository

    Hoteit, Ibrahim

    2010-03-02

    An eddy-permitting adjoint-based assimilation system has been implemented to estimate the state of the tropical Pacific Ocean. The system uses the Massachusetts Institute of Technology\\'s general circulation model and its adjoint. The adjoint method is used to adjust the model to observations by controlling the initial temperature and salinity; temperature, salinity, and horizontal velocities at the open boundaries; and surface fluxes of momentum, heat, and freshwater. The model is constrained with most of the available data sets in the tropical Pacific, including Tropical Atmosphere and Ocean, ARGO, expendable bathythermograph, and satellite SST and sea surface height data, and climatologies. Results of hindcast experiments in 2000 suggest that the iterated adjoint-based descent is able to significantly improve the model consistency with the multivariate data sets, providing a dynamically consistent realization of the tropical Pacific circulation that generally matches the observations to within specified errors. The estimated model state is evaluated both by comparisons with observations and by checking the controls, the momentum balances, and the representation of small-scale features that were not well sampled by the observations used in the assimilation. As part of these checks, the estimated controls are smoothed and applied in independent model runs to check that small changes in the controls do not greatly change the model hindcast. This is a simple ensemble-based uncertainty analysis. In addition, the original and smoothed controls are applied to a version of the model with doubled horizontal resolution resulting in a broadly similar “downscaled” hindcast, showing that the adjustments are not tuned to a single configuration (meaning resolution, topography, and parameter settings). The time-evolving model state and the adjusted controls should be useful for analysis or to supply the forcing, initial, and boundary conditions for runs of other models.

  16. Protein instability and immunogenicity: roadblocks to clinical application of injectable protein delivery systems for sustained release.

    Science.gov (United States)

    Jiskoot, Wim; Randolph, Theodore W; Volkin, David B; Middaugh, C Russell; Schöneich, Christian; Winter, Gerhard; Friess, Wolfgang; Crommelin, Daan J A; Carpenter, John F

    2012-03-01

    Protein instability and immunogenicity are two main roadblocks to the clinical success of novel protein drug delivery systems. In this commentary, we discuss the need for more extensive analytical characterization in relation to concerns about protein instability in injectable drug delivery systems for sustained release. We then will briefly address immunogenicity concerns and outline current best practices for using state-of-the-art analytical assays to monitor protein stability for both conventional and novel therapeutic protein dosage forms. Next, we provide a summary of the stresses on proteins arising during preparation of drug delivery systems and subsequent in vivo release. We note the challenges and difficulties in achieving the absolute requirement of quantitatively assessing the degradation of protein molecules in a drug delivery system. We describe the potential roles for academic research in further improving protein stability and developing new analytical technologies to detect protein degradation byproducts in novel drug delivery systems. Finally, we provide recommendations for the appropriate approaches to formulation design and assay development to ensure that stable, minimally immunogenic formulations of therapeutic proteins are created. These approaches should help to increase the probability that novel drug delivery systems for sustained protein release will become more readily available as effective therapeutic agents to treat and benefit patients. Copyright © 2011 Wiley Periodicals, Inc.

  17. Portable Filtered Air Suction System for Released Radioactive Gases Prevention under a Severe Accident of NPPs

    International Nuclear Information System (INIS)

    Gu, Beom W.; Choi, Su Y.; Rim, Chun T.

    2013-01-01

    In this paper, the portable filtered air suction system (PoFASS) for released radioactive gases prevention under a severe accident of NPP is proposed. This technology can prevent the release of the radioactive gases to the atmosphere and it can be more economical than FVCS because PoFASS can cover many NPPs with its high mobility. The conceptual design of PoFASS, which has the highest cost effectiveness and robustness to the environment condition such as wind velocity and precipitation, is suggested and the related previous research is introduced in this paper. The portable filtered air suction system (PoFASS) for released radioactive gases prevention can play a key role to mitigate the severe accident of NPP with its high cost effectiveness and robustness to the environment conditions. As further works, the detail design of PoFASS to fabricate a prototype for a demonstration will be proceeded. When released radioactive gases from the broken containment building in the severe accident of nuclear power plants (NPPs) such as the Chernobyl and Fukushima accidents occur, there are no ways to prevent the released radioactive gases spreading in the air. In order to solve this problem, several European NPPs have adopted the filtered vented containment system (FVCS), which can avoid the containment failure through a pressure relief capability to protect the containment building against overpressure. However, the installation cost of FVCS for a NPP is more than $10 million and this system has not been widely welcomed by NPP operating companies due to its high cost

  18. Eclipsing damped Lyα systems in the Sloan Digital Sky Survey Data Release 12★

    Science.gov (United States)

    Fathivavsari, H.; Petitjean, P.; Jamialahmadi, N.; Khosroshahi, H. G.; Rahmani, H.; Finley, H.; Noterdaeme, P.; Pâris, I.; Srianand, R.

    2018-04-01

    We present the results of our automatic search for proximate damped Lyα absorption (PDLA) systems in the quasar spectra from the Sloan Digital Sky Survey Data Release 12. We constrain our search to those PDLAs lying within 1500 km s-1 from the quasar to make sure that the broad DLA absorption trough masks most of the strong Lyα emission from the broad line region (BLR) of the quasar. When the Lyα emission from the BLR is blocked by these so-called eclipsing DLAs, narrow Lyα emission from the host galaxy could be revealed as a narrow emission line (NEL) in the DLA trough. We define a statistical sample of 399 eclipsing DLAs with log N(H I) ≥ 21.10. We divide our statistical sample into three subsamples based on the strength of the NEL detected in the DLA trough. By studying the stacked spectra of these subsamples, we found that absorption from high ionization species are stronger in DLAs with stronger NEL in their absorption core. Moreover, absorption from the excited states of species like Si II are also stronger in DLAs with stronger NEL. We also found no correlation between the luminosity of the Lyα NEL and the quasar luminosity. These observations are consistent with a scenario in which the DLAs with stronger NEL are denser and physically closer to the quasar. We propose that these eclipsing DLAs could be the product of the interaction between infalling and outflowing gas. High resolution spectroscopic observation would be needed to shed some light on the nature of these eclipsing DLAs.

  19. SU-E-J-211: Assessing the Consistency of the ViewRay 0.35 T MRI System

    International Nuclear Information System (INIS)

    Yan, Y; Saenz, D; Bayouth, J; Paliwal, B

    2015-01-01

    Purpose: ViewRay is a novel image-guided radiotherapy approach with an integrated 0.35 T MR unit and three Cobalt-60 heads. In order to continuously ensure the high resolution and high soft tissue contrast available in MR images, we quantified a multitude of relevant imaging parameters over a period of six months to establish its stability and imaging quality. In the assessment process, consideration is also given to the need to establish the number of tests required to have confidence in the performance of the system for radiation therapy planning applications. Methods: Daily, weekly, monthly and annual imaging tests were performed over a period of six months using standardized phantoms (a 24 cm diameter sphere and the ACR phantom) to quantify the performance of the system. In addition to the ACR and NEMA recommended tests, we also included element testing, spatial integrity, Eddy current and magnetic field inhomogeneity measurements. The ACR test is used for assessing the following parameters for T1 and T2: geometric accuracy, high contrast spatial resolution, slice thickness accuracy, slice position accuracy, percent signal ghosting, low contrast object detectability. It also includes percent image uniformity (PIU) for T1. The NEMA test is primarily designed to check SNR and PIU. Results: Over the period of six months, all the parameters were maintained within the recommendations provided in the ACR and NEMA standards. PIU and SNR were found to be sensitive to malfunctions in the components of the multileaf collimators. Details of the findings will be presented. Conclusion: The data suggests that ViewRay imaging system has functioned in a consistent and reliable manner. MR imaging from ViewRay 0.35T system complies with the ACR and NEMA recommended acceptance standards

  20. SU-E-J-211: Assessing the Consistency of the ViewRay 0.35 T MRI System

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Y; Saenz, D; Bayouth, J; Paliwal, B [University of Wisconsin, Madison, WI (United States)

    2015-06-15

    Purpose: ViewRay is a novel image-guided radiotherapy approach with an integrated 0.35 T MR unit and three Cobalt-60 heads. In order to continuously ensure the high resolution and high soft tissue contrast available in MR images, we quantified a multitude of relevant imaging parameters over a period of six months to establish its stability and imaging quality. In the assessment process, consideration is also given to the need to establish the number of tests required to have confidence in the performance of the system for radiation therapy planning applications. Methods: Daily, weekly, monthly and annual imaging tests were performed over a period of six months using standardized phantoms (a 24 cm diameter sphere and the ACR phantom) to quantify the performance of the system. In addition to the ACR and NEMA recommended tests, we also included element testing, spatial integrity, Eddy current and magnetic field inhomogeneity measurements. The ACR test is used for assessing the following parameters for T1 and T2: geometric accuracy, high contrast spatial resolution, slice thickness accuracy, slice position accuracy, percent signal ghosting, low contrast object detectability. It also includes percent image uniformity (PIU) for T1. The NEMA test is primarily designed to check SNR and PIU. Results: Over the period of six months, all the parameters were maintained within the recommendations provided in the ACR and NEMA standards. PIU and SNR were found to be sensitive to malfunctions in the components of the multileaf collimators. Details of the findings will be presented. Conclusion: The data suggests that ViewRay imaging system has functioned in a consistent and reliable manner. MR imaging from ViewRay 0.35T system complies with the ACR and NEMA recommended acceptance standards.

  1. Environmental effects of normal and off-normal releases of tritium from CTR systems

    International Nuclear Information System (INIS)

    McKone, T.E.

    1978-08-01

    Near term fusion technology will utilize the deuterium-tritium reaction. To quantify the magnitude of the hazard presented by major tritium release mechanisms, a method is presented for determining doses to the public from releases of tritium as tritiated water vapor or tritiated lithium compounds. Inclusion of this method in a computer model is described. This model uses the Gaussian dispersion method to predict distribution of tritium species in the downwind environment. Movement of tritium into biological systems is determined by treating these systems as a series of interacting water compartments. Dispersion and uptake calculations are applied to two sample sites in order to predict health effects. These effects are compared to the long range effect of introducing tritium into the world water system

  2. Adequate Measuring Technology and System of Fission Gas release Behavior from Voloxidation Process

    International Nuclear Information System (INIS)

    Park, Geun Il; Park, J. J.; Jung, I. H.; Shin, J. M.; Yang, M. S.; Song, K. C.

    2006-09-01

    Based on the published literature and an understanding of available hot cell technologies, more accurate measuring methods for each volatile fission product released from voloxidation process were reviewed and selected. The conceptual design of an apparatus for measuring volatile and/or semi-volatile fission products released from spent fuel was prepared. It was identified that on-line measurement techniques can be applied for gamma-emitting fission products, and off-line measurement such as chemical/or neutron activation analysis can applied for analyzing beta-emitting fission gases. Collection methods using appropriate material or solutions were selected to measure the release fraction of beta-emitting gaseous fission products at IMEF M6 hot cell. Especially, the on-line gamma-ray counting system for monitoring of 85Kr and the off-line measuring system of 14C was established. On-line measuring system for obtaining removal ratios of the semi-volatile fission products, mainly gamma-emitting fission products such as Cs, Ru etc., was also developed at IMEF M6 hot cell which was based on by measuring fuel inventory before and after the voloxidation test through gamma measuring technique. The development of this measurement system may enable basic information to be obtained to support design of the off-gas treatment system for the voloxidation process at INL, USA

  3. Application of dynamic modeling for assessing the impact of radioactive releases to water sewer systems

    International Nuclear Information System (INIS)

    Sundell-Bergman, Synnove; Avila, Rodolfo; Cruz, Idalmis de la

    2008-01-01

    Full text: Potential radiological emergencies due to accidental or malicious acts involving nuclear materials requires tools for emergency dose assessment to help in the planning of countermeasures. In urban areas, the municipal sewage systems will receive the wastewater from households, industries and hospitals as well as the run-off water. Investigations have shown that sewage sludge is a sensitive indicator for radionuclides released from hospitals or spread via the atmosphere and thus simulation modelling of the fate of radionuclides entering sewage treatment plants via urban drainage systems could prove useful in emergency situations. A dynamic model (LUCIA) has been developed to assess the radiological consequences of non-homogenous releases of radionuclides to the sewage plants. In the first step the focussing has been on radioactive liquid releases from hospitals and the predictions show that there is a significant probability (> 0,2) that the sewage worker doses exceed 10 μSv/y while doses to farmers or fishermen (downstream plants) are marginal. Comparison of measured and estimated concentration values for iodine-131 reveal that the predictions made by LUCIA are reasonably good and fall within a factor of 2. For the purpose of emergency preparedness, scenarios have been defined and the fate of released radionuclides has been assessed. The main features of the LUCIA model will be presented and the application of the tool for emergency preparedness will be discussed. (author)

  4. A general approach to the testing of binary solubility systems for thermodynamic consistency. Consolidated Fuel Reprocessing Program

    Science.gov (United States)

    Hamm, L. L.; Vanbrunt, V.

    1982-08-01

    The numerical solution to the ordinary differential equation which describes the high-pressure vapor-liquid equilibria of a binary system where one of the components is supercritical and exists as a noncondensable gas in the pure state is considered with emphasis on the implicit Runge-Kuta and orthogonal collocation methods. Some preliminary results indicate that the implicit Runge-Kutta method is superior. Due to the extreme nonlinearity of thermodynamic properties in the region near the critical locus, and extended cubic spline fitting technique is devised for correlating the P-x data. The least-squares criterion is employed in smoothing the experimental data. The technique could easily be applied to any thermodynamic data by changing the endpoint requirements. The volumetric behavior of the systems must be given or predicted in order to perform thermodynamic consistency tests. A general procedure is developed for predicting the volumetric behavior required and some indication as to the expected limit of accuracy is given.

  5. Dual turn-on fluorescence signal-based controlled release system for real-time monitoring of drug release dynamics in living cells and tumor tissues.

    Science.gov (United States)

    Kong, Xiuqi; Dong, Baoli; Song, Xuezhen; Wang, Chao; Zhang, Nan; Lin, Weiying

    2018-01-01

    Controlled release systems with capabilities for direct and real-time monitoring of the release and dynamics of drugs in living systems are of great value for cancer chemotherapy. Herein, we describe a novel dual turn-on fluorescence signal-based controlled release system ( CDox ), in which the chemotherapy drug doxorubicin ( Dox ) and the fluorescent dye ( CH ) are conjugated by a hydrazone moiety, a pH-responsive cleavable linker. CDox itself shows nearly no fluorescence as the fluorescence of CH and Dox is essentially quenched by the C=N isomerization and N-N free rotation. However, when activated under acidic conditions, CDox could be hydrolyzed to afford Dox and CH , resulting in dual turn-on signals with emission peaks at 595 nm and 488 nm, respectively. Notably, CDox exhibits a desirable controlled release feature as the hydrolysis rate is limited by the steric hindrance effect from both the Dox and CH moieties. Cytotoxicity assays indicate that CDox shows much lower cytotoxicity relative to Dox , and displays higher cell inhibition rate to cancer than normal cells. With the aid of the dual turn-on fluorescence at different wavelengths, the drug release dynamics of CDox in living HepG2 and 4T-1 cells was monitored in double channels in a real-time fashion. Importantly, two-photon fluorescence imaging of CDox in living tumor tissues was also successfully performed by high-definition 3D imaging. We expect that the unique controlled release system illustrated herein could provide a powerful means to investigate modes of action of drugs, which is critical for development of much more robust and effective chemotherapy drugs.

  6. Consistency of orthodox gravity

    Energy Technology Data Exchange (ETDEWEB)

    Bellucci, S. [INFN, Frascati (Italy). Laboratori Nazionali di Frascati; Shiekh, A. [International Centre for Theoretical Physics, Trieste (Italy)

    1997-01-01

    A recent proposal for quantizing gravity is investigated for self consistency. The existence of a fixed-point all-order solution is found, corresponding to a consistent quantum gravity. A criterion to unify couplings is suggested, by invoking an application of their argument to more complex systems.

  7. Decomposition and nutrient release of leguminous plants in coffee agroforestry systems

    Directory of Open Access Journals (Sweden)

    Eduardo da Silva Matos

    2011-02-01

    Full Text Available Leguminous plants used as green manure are an important nutrient source for coffee plantations, especially for soils with low nutrient levels. Field experiments were conducted in the Zona da Mata of Minas Gerais State, Brazil to evaluate the decomposition and nutrient release rates of four leguminous species used as green manures (Arachis pintoi, Calopogonium mucunoides, Stizolobium aterrimum and Stylosanthes guianensis in a coffee agroforestry system under two different climate conditions. The initial N contents in plant residues varied from 25.7 to 37.0 g kg-1 and P from 2.4 to 3.0 g kg-1. The lignin/N, lignin/polyphenol and (lignin+polyphenol/N ratios were low in all residues studied. Mass loss rates were highest in the first 15 days, when 25 % of the residues were decomposed. From 15 to 30 days, the decomposition rate decreased on both farms. On the farm in Pedra Dourada (PD, the decomposition constant k increased in the order C. mucunoides < S. aterrimum < S. guianensis < A. pintoi. On the farm in Araponga (ARA, there was no difference in the decomposition rate among leguminous plants. The N release rates varied from 0.0036 to 0.0096 d-1. Around 32 % of the total N content in the plant material was released in the first 15 days. In ARA, the N concentration in the S. aterrimum residues was always significantly higher than in the other residues. At the end of 360 days, the N released was 78 % in ARA and 89 % in PD of the initial content. Phosphorus was the most rapidly released nutrient (k values from 0.0165 to 0.0394 d-1. Residue decomposition and nutrient release did not correlate with initial residue chemistry and biochemistry, but differences in climatic conditions between the two study sites modified the decomposition rate constants.

  8. Internally consistent thermodynamic data for aqueous species in the system Na-K-Al-Si-O-H-Cl

    Science.gov (United States)

    Miron, George D.; Wagner, Thomas; Kulik, Dmitrii A.; Heinrich, Christoph A.

    2016-08-01

    A large amount of critically evaluated experimental data on mineral solubility, covering the entire Na-K-Al-Si-O-H-Cl system over wide ranges in temperature and pressure, was used to simultaneously refine the standard state Gibbs energies of aqueous ions and complexes in the framework of the revised Helgeson-Kirkham-Flowers equation of state. The thermodynamic properties of the solubility-controlling minerals were adopted from the internally consistent dataset of Holland and Powell (2002; Thermocalc dataset ds55). The global optimization of Gibbs energies of aqueous species, performed with the GEMSFITS code (Miron et al., 2015), was set up in such a way that the association equilibria for ion pairs and complexes, independently derived from conductance and potentiometric data, are always maintained. This was achieved by introducing reaction constraints into the parameter optimization that adjust Gibbs energies of complexes by their respective Gibbs energy effects of reaction, whenever the Gibbs energies of reactant species (ions) are changed. The optimized thermodynamic dataset is reported with confidence intervals for all parameters evaluated by Monte Carlo trial calculations. The new thermodynamic dataset is shown to reproduce all available fluid-mineral phase equilibria and mineral solubility data with good accuracy and precision over wide ranges in temperature (25-800 °C), pressure (1 bar to 5 kbar) and composition (salt concentrations up to 5 molal). The global data optimization process adopted in this study can be readily repeated any time when extensions to new chemical elements and species are needed, when new experimental data become available, or when a different aqueous activity model or equation of state should be used. This work serves as a proof of concept that our optimization strategy is feasible and successful in generating a thermodynamic dataset reproducing all fluid-mineral and aqueous speciation equilibria in the Na-K-Al-Si-O-H-Cl system within

  9. Pneumatic transport system development: residuals and releases program at Westinghouse Cheswick site

    International Nuclear Information System (INIS)

    Larouere, P.J.; Shoulders, J.L.

    1979-01-01

    Plutonium oxide and uranium oxide powders are processed within glove boxes or within confinement systems during the fabrication of mixed oxide (MOX) pellets for recycle fuel. The release of these powders to the glove box or to the confinement results in some airborne material that is deposited in the enclosure or is carried in the air streams to the effluent air filtration system. Release tests on simulated leaks in pneumatic transport equipment and release tests on simulated failures with powder blending equipment were conducted. A task to develop pneumatic transport for the movement of powders within an MOX fabrication plant has been underway at the Westinghouse Research Laboratories. While testing and evaluating selected pneumatic transport components on a full scale were in progress, it was deemed necessary that final verification of the technology would have to be performed with plutonium-bearing powders because of the marked differences in certain properties of plutonium from those of uranium oxides. A smaller was designed and constructed for the planned installation in glove boxes at the Westinghouse Plutonium Fuel Development Laboratory. However, prior to use with plutonium it was agreed that this system be set up and tested with uranium oxide powder. The test program conducted at the Westinghouse Cheswick site was divided into two major parts. The first of these examined the residuals left as a result of the pneumatic transport of nuclear fuel powders and verified the operability of this one-third scale system. The second part of the program studied the amount of powder released to the air when off-standard process procedures or maintenance operations were conducted on the pneumatic transport system. Air samplers located within the walk-in box housing the transport loop were used to measure the solids concentration in the air. From this information, the total amount of airborne powder was determined

  10. Effect of temperature and ph on the drug release rate from a polymer conjugate system

    International Nuclear Information System (INIS)

    Kenawy, E.; Abdel-Hay, F.I.; El-Newehy, M.H.; Ottenbrite, R.M.

    2005-01-01

    Hydroximide and A-methylhydroxamic acid of poly(ethylene-altmaleic anhydride) (average MW 100-500 k) were used as a carrier for a new drug delivery system. The synthesis of the hydroximide and N methylhydroxamic acid of poly(ethylene-alt-maleic anhydride) were carried out by chemical modification of poly(ethylene-alt-maleic anhydride) with hydroxylamine and N-methyl hydroxylamine, respectively, in N,N- dimethylformamide at room temperature to yield water soluble copolymer. Ketoprofen was reacted with hydroximide and N-methylhydroxamic acid derivatives of poly(ethylene-alt-maleic anhydride) using dicyclohexylcarbodiimide as condensation agent at -5 degree C to yield water insoluble ketoprofen conjugates. All products were characterized by elemental analysis, FTIR and 1HNMR spectra. The in-vitro ketoprofen release was carried out by UV spectrophotometer at max =260 nm. The results demonstrated the effectiveness of hydroximide and N-methylhydroxamic acid of polyethylene-alt-maleic anhydride) as a drug delivery system. The release rates were studied at various ph and temperatures. The copolymer-drug adducts released the drug very slowly at the low ph found in the stomach thus protecting the drug from the action of high concentrations of digestive acids. These results showed the usefulness of hydroxamic acid polymer-drug conjugates as a new drug delivery system for drugs to be targeted to sites in the GI system

  11. Furfural production from biomass pretreatment hydrolysate using vapor-releasing reactor system.

    Science.gov (United States)

    Liu, Lu; Chang, Hou-Min; Jameel, Hasan; Park, Sunkyu

    2018-03-01

    Biomass hydrolysate from autohydrolysis pretreatment was used for furfural production considering it is in rich of xylose, xylo-oligomers, and other decomposition products from hemicellulose structure. By using the vapor-releasing reactor system, furfural was protected from degradation by separating it from the reaction media. The maximum furfural yield of 73% was achieved at 200 °C for biomass hydrolysate without the use of the catalyst. This is because the presence of organic acids such as acetic acid in hydrolysate functioned as a catalyst. According to the results in this study, biomass hydrolysate with a vapor-releasing system proves to be efficient for furfural production. The biorefinery process which allows the separation of xylose-rich autohydrolysate from other parts from biomass feedstock also improves the overall application of the biomass. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. NIR responsive liposomal system for rapid release of drugs in cancer therapy

    Directory of Open Access Journals (Sweden)

    Chen MM

    2017-06-01

    Full Text Available Ming-Mao Chen,1 Yuan-Yuan Liu,1 Guang-Hao Su,2 Fei-Fei Song,1 Yan Liu,3 Qi-Qing Zhang1,4 1Institute of Biomedical and Pharmaceutical Technology, Fuzhou University, Fuzhou, 2Institute of Pediatric Research, Children’s Hospital of Soochow University, Suzhou, 3State Key Lab of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, 4Key Laboratory of Biomedical Material of Tianjin, Institute of Biomedical Engineering, Chinese Academy of Medical Science & Peking Union Medical College, Tianjin, People’s Republic of China Abstract: To design a rapid release liposomal system for cancer therapy, a NIR responsive bubble-generating thermosensitive liposome (BTSL system combined with photothermal agent (Cypate, doxorubicin (DOX, and NH4HCO3 was developed. Cypate/DOX-BTSL exhibited a good aqueous stability, photostability, and photothermal effect. In vitro release suggested that the amounts of DOX released from BTSL were obviously higher than that of (NH42SO4 liposomes at 42°C. After NIR irradiation, the hyperthermic temperature induced by Cypate led to the decomposition of NH4HCO3 and the generation of a large number of CO2 bubbles, triggering a rapid release of drugs. Confocal laser scanning microscope and acridine orange staining indicated that Cypate/DOX-BTSL upon irradiation could facilitate to disrupt the lysosomal membranes and realize endolysosomal escape into cytosol, improving the intracellular uptake of DOX clearly. MTT and trypan blue staining implied that the cell damage of Cypate/DOX-BTSL with NIR irradiation was more severe than that in the groups without irradiation. In vivo results indicated that Cypate/DOX-BTSL with irradiation could dramatically increase the accumulation of DOX in tumor, inhibit tumor growth, and reduce systemic side effects of DOX. These data demonstrated that Cypate/DOX-BTSL has the potential to be used as a NIR responsive liposomal system for a rapid

  13. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets.

    Science.gov (United States)

    Pantelic, J; Tham, K W; Licina, D

    2015-12-01

    The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal manikin at distances between 1 and 4 m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure. Exposure to cough droplets was reduced with increasing distance between cough source and exposed occupant. The results from this study show that an advanced air distribution system such as personalized ventilation reduces exposure to cough-released droplets better than commonly applied overhead mixing ventilation. This work can inform HVAC engineers about different aspects of air distribution systems’ performance and can serve as an aid in making critical design decisions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Drug release control in delivery system for biodegradable polymer drugs by γ-radiation

    International Nuclear Information System (INIS)

    Yoshioka, Sumie; Azo, Yukio; Kojima, Shigeo

    1997-01-01

    Characterizations of the drug release from microsphere and hydrogel preparation made from biodegradable polymers were investigated aiming at development of a drug delivery system which allows an optimum drug delivery and the identification of the factors which control its delivery. Poly-lactic acid microspheres containing 10% of progesterone were produced from poly DL-lactic acid and exposed to γ-ray at 5-1000 kGy. And its glass transition temperature (Tg) was determined by differential scanning calorimetry. The temperature was gradually lowered with an increase in the dose of radiation. Tg of the microsphere exposed at 1000 kGy was lower by 10degC compared with the untreated one, showing that Tg control is possible without changing the size distribution of microsphere. Then, the amount of progesterone released from microsphere was determined. The release rate of the drug linearly increased with a square root of radiation time. These results indicate that the control of drug release rate is possible through controling the microsphere's Tg by γ-ray radiation. (M.N.)

  15. Evidence of arsenic release promoted by disinfection by-products within drinking-water distribution systems.

    Science.gov (United States)

    Andra, Syam S; Makris, Konstantinos C; Botsaris, George; Charisiadis, Pantelis; Kalyvas, Harris; Costa, Costas N

    2014-02-15

    Changes in disinfectant type could trigger a cascade of reactions releasing pipe-anchored metals/metalloids into finished water. However, the effect of pre-formed disinfection by-products on the release of sorbed contaminants (arsenic-As in particular) from drinking water distribution system pipe scales remains unexplored. A bench-scale study using a factorial experimental design was performed to evaluate the independent and interaction effects of trihalomethanes (TTHM) and haloacetic acids (HAA) on arsenic (As) release from either scales-only or scale-biofilm conglomerates (SBC) both anchored on asbestos/cement pipe coupons. A model biofilm (Pseudomonas aeruginosa) was allowed to grow on select pipe coupons prior experimentation. Either TTHM or HAA individual dosing did not promote As release from either scales only or SBC, detecting water. In the case of scales-only coupons, the combination of the highest spike level of TTHM and HAA significantly (pwater in pipe networks remains to be investigated in the field. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Consistent model driven architecture

    Science.gov (United States)

    Niepostyn, Stanisław J.

    2015-09-01

    The goal of the MDA is to produce software systems from abstract models in a way where human interaction is restricted to a minimum. These abstract models are based on the UML language. However, the semantics of UML models is defined in a natural language. Subsequently the verification of consistency of these diagrams is needed in order to identify errors in requirements at the early stage of the development process. The verification of consistency is difficult due to a semi-formal nature of UML diagrams. We propose automatic verification of consistency of the series of UML diagrams originating from abstract models implemented with our consistency rules. This Consistent Model Driven Architecture approach enables us to generate automatically complete workflow applications from consistent and complete models developed from abstract models (e.g. Business Context Diagram). Therefore, our method can be used to check practicability (feasibility) of software architecture models.

  17. Development of Modified-Release Tablets of Zolpidem Tartrate by Biphasic Quick/Slow Delivery System

    OpenAIRE

    Mahapatra, Anjan Kumar; Sameeraja, N. H.; Murthy, P. N.

    2014-01-01

    Zolpidem tartrate is a non-benzodiazepine analogue of imidazopyridine of sedative and hypnotic category. It has a short half-life with usual dosage regimen being 5 mg, two times a day, or 10 mg, once daily. The duration of action is considered too short in certain circumstances. Thus, it is desirable to lengthen the duration of action. The formulation design was implemented by preparing extended-release tablets of zolpidem tartrate using the biphasic delivery system technology, where sodium s...

  18. Magnetic nanoparticles for a new drug delivery system to control quercetin releasing for cancer chemotherapy

    International Nuclear Information System (INIS)

    Barreto, A. C. H.; Santiago, V. R.; Mazzetto, S. E.; Denardin, J. C.; Lavín, R.; Mele, Giuseppe; Ribeiro, M. E. N. P.; Vieira, Icaro G. P.; Gonçalves, Tamara; Ricardo, N. M. P. S.

    2011-01-01

    Quercetin belongs to the chemical class of flavonoids and can be found in many common foods, such as apples, nuts, berries, etc. It has been demonstrated that quercetin has a wide array of biological effects that are considered beneficial to health treatment, mainly as anticancer. However, therapeutic applications of quercetin have been restricted to oral administration due to its sparing solubility in water and instability in physiological medium. A drug delivery methodology was proposed in this work to study a new quercetin release system in the form of magnetite–quercetin–copolymer (MQC). These materials were characterized through XRD, TEM, IR, and Thermal analysis. In addition, the magnetization curves and quercetin releasing experiments were performed. It was observed a nanoparticle average diameter of 11.5 and 32.5 nm at Fe 3 O 4 and MQC, respectively. The presence of magnetic nanoparticles in this system offers the promise of targeting specific organs within the body. These results indicate the great potential for future applications of the MQC to be used as a new quercetin release system.

  19. SMA-Based System for Environmental Sensors Released from an Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    Lorenzo Pellone

    2017-01-01

    Full Text Available In the work at hand, a shape memory alloy (SMA-based system is presented. The system, conceived for releasing environmental sensors from ground or small unmanned aerial vehicles, UAV (often named UAS, unmanned aerial system, is made of a door, integrated into the bottom of the fuselage, a device distributor, operated by a couple of antagonistic SMA springs, and a kinematic chain, to synchronize the deployment operation with the system movement. On the basis of the specifications (weight, available space, energy supply, sensors size, etc., the system design was addressed. After having identified the main system characteristics, a representative mock-up was manufactured, featuring the bottom part of the reference fuselage. Functionality tests were performed to prove the system capability to release the sensors; a detailed characterization was finally carried out, mainly finalized at correlating the kinematic chain displacement with the SMA spring temperature and the supplied electrical power. A comparison between theoretical predictions and experimental outcomes showed good agreement.

  20. Distributed emergency response system to model dispersion and deposition of atmospheric releases

    International Nuclear Information System (INIS)

    Taylor, S.S.

    1985-04-01

    Aging hardware and software and increasing commitments by the Departments of Energy and Defense have led us to develop a new, expanded system to replace the existing Atmospheric Release Advisory Capability (ARAC) system. This distributed, computer-based, emergency response system is used by state and federal agencies to assess the environmental health hazards resulting from an accidental release of radioactive material into the atmosphere. Like its predecessor, the expanded system uses local meteorology (e.g., wind speed and wind direction), as well as terrain information, to simulate the transport and dispersion of the airborne material. The system also calculates deposition and dose and displays them graphically over base maps of the local geography for use by on-site authorities. This paper discusses the limitations of the existing ARAC system. It also discusses the components and functionality of the new system, the technical difficulties encountered and resolved in its design and implementation, and the software methodologies and tools employed in its development

  1. Workplace Exposure to Titanium Dioxide Nanopowder Released from a Bag Filter System

    Directory of Open Access Journals (Sweden)

    Jun Ho Ji

    2015-01-01

    Full Text Available Many researchers who use laboratory-scale synthesis systems to manufacture nanomaterials could be easily exposed to airborne nanomaterials during the research and development stage. This study used various real-time aerosol detectors to investigate the presence of nanoaerosols in a laboratory used to manufacture titanium dioxide (TiO2. The TiO2 nanopowders were produced via flame synthesis and collected by a bag filter system for subsequent harvesting. Highly concentrated nanopowders were released from the outlet of the bag filter system into the laboratory. The fractional particle collection efficiency of the bag filter system was only 20% at particle diameter of 100 nm, which is much lower than the performance of a high-efficiency particulate air (HEPA filter. Furthermore, the laboratory hood system was inadequate to fully exhaust the air discharged from the bag filter system. Unbalanced air flow rates between bag filter and laboratory hood systems could result in high exposure to nanopowder in laboratory settings. Finally, we simulated behavior of nanopowders released in the laboratory using computational fluid dynamics (CFD.

  2. Structured emulsion-based delivery systems: controlling the digestion and release of lipophilic food components.

    Science.gov (United States)

    McClements, David Julian; Li, Yan

    2010-09-15

    There is a need for edible delivery systems to encapsulate, protect and release bioactive and functional lipophilic constituents within the food and pharmaceutical industries. These delivery systems could be used for a number of purposes: controlling lipid bioavailability; targeting the delivery of bioactive components within the gastrointestinal tract; and designing food matrices that delay lipid digestion and induce satiety. Emulsion technology is particularly suited for the design and fabrication of delivery systems for lipids. In this article we provide an overview of a number of emulsion-based technologies that can be used as edible delivery systems by the food and other industries, including conventional emulsions, nanoemulsions, multilayer emulsions, solid lipid particles, and filled hydrogel particles. Each of these delivery systems can be produced from food-grade (GRAS) ingredients (e.g., lipids, proteins, polysaccharides, surfactants, and minerals) using relatively simple processing operations (e.g., mixing, homogenizing, and thermal processing). The structure, preparation, and utilization of each type of delivery system for controlling lipid digestion are discussed. This knowledge can be used to select the most appropriate emulsion-based delivery system for specific applications, such as encapsulation, controlled digestion, and targeted release. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Effect for Recovery of the Containment Spray System to the Release of Cesium

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Mi Ro [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    In the perspective of the amount of Cs-137, the mass of Cs-137 correspondent with the 100TBq is calculated as 32g. However, during the severe accident, if the containment has been failed, it is generally expected that the mass of Cs-137 released to the environment is more than 1kg for most accident sequences So, the review and improvement of the PSA model in order to reduce containment failure frequency should be needed. Actually, the current PSA model is known to be constructed by the conservative assumptions, especially in the view point of Level 2 PSA model. Therefore, it is necessary to find this conservatism and to improve the Model using the reasonable assumptions. All of the domestic operating nuclear power plants are required to prepare the Accident Management Plan within 3 years and this Accident Management Plan should have to meet the New Safety Goal including the requirement that the sum of the accident frequency that the release of the radioactive nuclide Cs-137 to the environment exceeds the 100TBq should be less than 1.0E-6/RY. The containment spray system is the only facility that mitigates the containment over-pressurization in the operating nuclear power plants, such as Westinghouse type or OPR1000 type. In this study, the effects of the containment spray system recovery on the amount of Cesium released to the environment were analyzed. If the recovery of the containment spray system can be applied to the PSA model, it is expected that the containment failure frequency and also the amount of cesium released to the environment can be greatly reduced.

  4. Cardiac arrest during gamete release in chum salmon regulated by the parasympathetic nerve system.

    Directory of Open Access Journals (Sweden)

    Yuya Makiguchi

    Full Text Available Cardiac arrest caused by startling stimuli, such as visual and vibration stimuli, has been reported in some animals and could be considered as an extraordinary case of bradycardia and defined as reversible missed heart beats. Variability of the heart rate is established as a balance between an autonomic system, namely cholinergic vagus inhibition, and excitatory adrenergic stimulation of neural and hormonal action in teleost. However, the cardiac arrest and its regulating nervous mechanism remain poorly understood. We show, by using electrocardiogram (ECG data loggers, that cardiac arrest occurs in chum salmon (Oncorhynchus keta at the moment of gamete release for 7.39+/-1.61 s in females and for 5.20+/-0.97 s in males. The increase in heart rate during spawning behavior relative to the background rate during the resting period suggests that cardiac arrest is a characteristic physiological phenomenon of the extraordinarily high heart rate during spawning behavior. The ECG morphological analysis showed a peaked and tall T-wave adjacent to the cardiac arrest, indicating an increase in potassium permeability in cardiac muscle cells, which would function to retard the cardiac action potential. Pharmacological studies showed that the cardiac arrest was abolished by injection of atropine, a muscarinic receptor antagonist, revealing that the cardiac arrest is a reflex response of the parasympathetic nerve system, although injection of sotalol, a beta-adrenergic antagonist, did not affect the cardiac arrest. We conclude that cardiac arrest during gamete release in spawning release in spawning chum salmon is a physiological reflex response controlled by the parasympathetic nervous system. This cardiac arrest represents a response to the gaping behavior that occurs at the moment of gamete release.

  5. Construction of a novel pH-sensitive drug release system from mesoporous silica tablets coated with Eudragit

    Science.gov (United States)

    Xu, Yingpu; Qu, Fengyu; Wang, Yu; Lin, Huiming; Wu, Xiang; Jin, Yingxue

    2011-03-01

    A novel pH-sensitive drug release system has been established by coating Eudragit (Eud) on drug-loaded mesoporous silica (MS) tablets. The release rate of ibuprofen (IBU) from the MS was retarded by coating with Eudragit S-100, and the higher retardation was due to the increase of coating concentration and the coating layers. The target position of the release depended on the pH of the release medium, which was confirmed by the drug release from IBU/MS/Eud increasing rapidly with the change of medium pH from 1.2 to 7.4. This drug delivery system could prohibit irritant drug from leaking in the stomach and make it only release in the intestine. The loaded and unloaded drug samples were characterized by powder X-ray diffraction (XRD), Fourier transform infrared spectrometer (FTIR), N 2 adsorption/desorption, scanning electron microscopy (SEM), and transmission electron microscopy (TEM).

  6. Effect of Fluoride-Releasing Adhesive Systems on the Mechanical Properties of Eroded Dentin.

    Science.gov (United States)

    Guedes, Ana Paula Albuquerque; Moda, Mariana Dias; Suzuki, Thaís Yumi Umeda; Godas, André Gustavo de Lima; Sundfeld, Renato Herman; Briso, André Luiz Fraga; Santos, Paulo Henrique dos

    2016-01-01

    The aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 µm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 µm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions.

  7. Unleashing elastic energy: dynamics of energy release in rubber bands and impulsive biological systems

    Science.gov (United States)

    Ilton, Mark; Cox, Suzanne; Egelmeers, Thijs; Patek, S. N.; Crosby, Alfred J.

    Impulsive biological systems - which include mantis shrimp, trap-jaw ants, and venus fly traps - can reach high speeds by using elastic elements to store and rapidly release energy. The material behavior and shape changes critical to achieving rapid energy release in these systems are largely unknown due to limitations of materials testing instruments operating at high speed and large displacement. In this work, we perform fundamental, proof-of-concept measurements on the tensile retraction of elastomers. Using high speed imaging, the kinematics of retraction are measured for elastomers with varying mechanical properties and geometry. Based on the kinematics, the rate of energy dissipation in the material is determined as a function of strain and strain-rate, along with a scaling relation which describes the dependence of maximum velocity on material properties. Understanding this scaling relation along with the material failure limits of the elastomer allows the prediction of material properties required for optimal performance. We demonstrate this concept experimentally by optimizing for maximum velocity in our synthetic model system, and achieve retraction velocities that exceed those in biological impulsive systems. This model system provides a foundation for future work connecting continuum performance to molecular architecture in impulsive systems.

  8. Liquid Effluent Monitoring Information System test plans releases 2.0 and 3.0

    International Nuclear Information System (INIS)

    Guettler, D.A.

    1995-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  9. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.0

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  10. Liquid Effluent Monitoring Information System test plans release 1.2

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  11. Diffusivity database (DDB) system for major rocks and buffer materials (Released on 2007/specification)

    International Nuclear Information System (INIS)

    Tochigi, Yoshikatsu; Shibata, Masahiro; Sato, Haruo; Kitamura, Akira

    2007-03-01

    The Diffusivity Database (DDB) System developed on early 2006 was upgraded to apply the data of effective diffusion coefficient of the nuclides in the rock matrix for the 'H12: Project to Establish the Scientific and Technical Basis for HLW Disposal in Japan', and the data in the buffer materials from literature survey was newly added. Some functions of data search and selection were reformed to improve the level of convenience. This DDB system (work on MS-Access TM ) is released to the public through Web server managed by JAEA. (author)

  12. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.1

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  13. System with embedded drug release and nanoparticle degradation sensor showing efficient rifampicin delivery into macrophages.

    Science.gov (United States)

    Trousil, Jiří; Filippov, Sergey K; Hrubý, Martin; Mazel, Tomáš; Syrová, Zdeňka; Cmarko, Dušan; Svidenská, Silvie; Matějková, Jana; Kováčik, Lubomír; Porsch, Bedřich; Konefał, Rafał; Lund, Reidar; Nyström, Bo; Raška, Ivan; Štěpánek, Petr

    2017-01-01

    We have developed a biodegradable, biocompatible system for the delivery of the antituberculotic antibiotic rifampicin with a built-in drug release and nanoparticle degradation fluorescence sensor. Polymer nanoparticles based on poly(ethylene oxide) monomethyl ether-block-poly(ε-caprolactone) were noncovalently loaded with rifampicin, a combination that, to best of our knowledge, was not previously described in the literature, which showed significant benefits. The nanoparticles contain a Förster resonance energy transfer (FRET) system that allows real-time assessment of drug release not only in vitro, but also in living macrophages where the mycobacteria typically reside as hard-to-kill intracellular parasites. The fluorophore also enables in situ monitoring of the enzymatic nanoparticle degradation in the macrophages. We show that the nanoparticles are efficiently taken up by macrophages, where they are very quickly associated with the lysosomal compartment. After drug release, the nanoparticles in the cmacrophages are enzymatically degraded, with half-life 88±11 min. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Calcium release-dependent inactivation precedes formation of the tubular system in developing rat cardiac myocytes.

    Science.gov (United States)

    Macková, Katarina; Zahradníková, Alexandra; Hoťka, Matej; Hoffmannová, Barbora; Zahradník, Ivan; Zahradníková, Alexandra

    2017-12-01

    Developing cardiac myocytes undergo substantial structural and functional changes transforming the mechanism of excitation-contraction coupling from the embryonic form, based on calcium influx through sarcolemmal DHPR calcium channels, to the adult form, relying on local calcium release through RYR calcium channels of sarcoplasmic reticulum stimulated by calcium influx. We characterized day-by-day the postnatal development of the structure of sarcolemma, using techniques of confocal fluorescence microscopy, and the development of the calcium current, measured by the whole-cell patch-clamp in isolated rat ventricular myocytes. We characterized the appearance and expansion of the t-tubule system and compared it with the appearance and progress of the calcium current inactivation induced by the release of calcium ions from sarcoplasmic reticulum as structural and functional measures of direct DHPR-RYR interaction. The release-dependent inactivation of calcium current preceded the development of the t-tubular system by several days, indicating formation of the first DHPR-RYR couplons at the surface sarcolemma and their later spreading close to contractile myofibrils with the growing t-tubules. Large variability of both of the measured parameters among individual myocytes indicates uneven maturation of myocytes within the growing myocardium.

  15. Oral controlled release drug delivery system and Characterization of oral tablets; A review

    Directory of Open Access Journals (Sweden)

    Muhammad Zaman

    2016-01-01

    Full Text Available Oral route of drug administration is considered as the safest and easiest route of drug administration. Control release drug delivery system is the emerging trend in the pharmaceuticals and the oral route is most suitable for such kind of drug delivery system. Oral route is more convenient for It all age group including both pediatric and geriatrics. There are various systems which are adopted to deliver drug in a controlled manner to different target sites through oral route. It includes diffusion controlled drug delivery systems; dissolution controlled drug delivery systems, osmotically controlled drug delivery systems, ion-exchange controlled drug delivery systems, hydrodynamically balanced systems, multi-Particulate drug delivery systems and microencapsulated drug delivery system. The systems are formulated using different natural, semi-synthetic and synthetic polymers. The purpose of the review is to provide information about the orally controlled drug delivery system, polymers which are used to formulate these systems and characterizations of one of the most convenient dosage form which is the tablets. 

  16. Magnetic Active Agent Release System (MAARS): evaluation of a new way for a reproducible, externally controlled drug release into the small intestine.

    Science.gov (United States)

    Dietzel, Christian T; Richert, Hendryk; Abert, Sandra; Merkel, Ute; Hippius, Marion; Stallmach, Andreas

    2012-08-10

    Human absorption studies are used to test new drug candidates for their bioavailability in different regions of the gastrointestinal tract. In order to replace invasive techniques (e.g. oral or rectal intubation) a variety of externally controlled capsule-based drug release systems has been developed. Most of these use ionizing radiation, internal batteries, heating elements or even chemicals for the localization and disintegration process of the capsule. This embodies potential harms for volunteers and patients. We report about a novel technique called "Magnetic Active Agent Release System" (MAARS), which uses purely magnetic effects for this purpose. In our trial thirteen healthy volunteers underwent a complete monitoring and release procedure of 250 mg acetylsalicylic acid (ASA) targeting the flexura duodenojejunalis and the mid-part of the jejunum. During all experiments MAARS initiated a sufficient drug release and was well tolerated. Beside this we also could show that the absorption of ASA is about two times faster in the more proximal region of the flexura duodenojejunalis with a tmax of 47±13 min compared to the more distal jejunum with tmax values of 100±10 min (p=0.031). Copyright © 2012 Elsevier B.V. All rights reserved.

  17. The systems containing clays and clay minerals from modified drug release: a review.

    Science.gov (United States)

    Rodrigues, Luís Alberto de Sousa; Figueiras, Ana; Veiga, Francisco; de Freitas, Rivelilson Mendes; Nunes, Lívio César Cunha; da Silva Filho, Edson Cavalcanti; da Silva Leite, Cleide Maria

    2013-03-01

    Clays are materials commonly used in the pharmaceutical industry, either as ingredients or as active ingredients. It was observed that when they are administered concurrently, they may interact with drugs reducing their absorption. Therefore, such interactions can be used to achieve technological and biopharmaceutical advantages, regarding the control of release. This review summarizes bibliographic (articles) and technological (patents) information on the use of systems containing clays and clay minerals in modified drug delivery. In this area, formulations such natural clay, commercial clay, synthetic clay, composites clay-polymers, nanocomposites clay-polymers, films and hidrogels composites clay-polymers are used to slow/extend or vectorize the release of drugs and consequently they increase their bioavailability. Finally, this review summarizes the fields of technology and biopharmaceutical applications, where clays are applied. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Stepwise encapsulation and controlled two-stage release system for cis-Diamminediiodoplatinum.

    Science.gov (United States)

    Chen, Yun; Li, Qian; Wu, Qingsheng

    2014-01-01

    cis-Diamminediiodoplatinum (cis-DIDP) is a cisplatin-like anticancer drug with higher anticancer activity, but lower stability and price than cisplatin. In this study, a cis-DIDP carrier system based on micro-sized stearic acid was prepared by an emulsion solvent evaporation method. The maximum drug loading capacity of cis-DIDP-loaded solid lipid nanoparticles was 22.03%, and their encapsulation efficiency was 97.24%. In vitro drug release in phosphate-buffered saline (pH =7.4) at 37.5°C exhibited a unique two-stage process, which could prove beneficial for patients with tumors and malignancies. MTT (3-[4,5-dimethylthiazol-2-yl]-2, 5-diphenyltetrazolium bromide) assay results showed that cis-DIDP released from cis-DIDP-loaded solid lipid nanoparticles had better inhibition activity than cis-DIDP that had not been loaded.

  19. Zein-alginate based oral drug delivery systems: Protection and release of therapeutic proteins.

    Science.gov (United States)

    Lee, Sungmun; Kim, Yeu-Chun; Park, Ji-Ho

    2016-12-30

    Reactive oxygen species (ROS) play an important role in the development of inflammatory bowel diseases. Superoxide dismutase (SOD) has a great therapeutic potential by scavenging superoxide that is one of ROS; however, in vivo application is limited especially when it is orally administered. SOD is easily degraded in vivo by the harsh conditions of gastrointestinal tract. Here, we design a zein-alginate based oral drug delivery system that protects SOD from the harsh conditions of gastrointestinal tract and releases it in the environment of the small intestine. SOD is encapsulated in zein-alginate nanoparticles (ZAN) via a phase separation method. We demonstrate that ZAN protect SOD from the harsh conditions of the stomach or small intestine condition. ZAN (200:40) at the weight ratio of 200mg zein to 40mg of alginate releases SOD in a pH dependent manner, and it releases 90.8±1.2% of encapsulated SOD at pH 7.4 in 2h, while only 11.4±0.4% of SOD was released at pH 1.3. The encapsulation efficiency of SOD in ZAN (200:40) was 62.1±2.0%. SOD in ZAN (200:40) reduced the intracellular ROS level and it saved 88.9±7.5% of Caco-2 cells from the toxic superoxide in 4 hours. Based on the results, zein-alginate based oral drug delivery systems will have numerous applications to drugs that are easily degradable in the harsh conditions of gastrointestinal tract. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Compression and release dynamics of an active matter system of Euglena gracilis

    Science.gov (United States)

    Lam, Amy; Tsang, Alan C. H.; Ouellette, Nicholas; Riedel-Kruse, Ingmar

    Active matter, defined as ensembles of self-propelled particles, encompasses a large variety of systems at all scales, from nanoparticles to bird flocks. Though various models and simulations have been created to describe the dynamics of these systems, experimental verification has been difficult to obtain. This is frequently due to the complex interaction rules which govern the particle behavior, in turn making systematic varying of parameters impossible. Here, we propose a model for predicting the system evolution of compression and release of an active system based on experiments and simulations. In particular, we consider ensembles of the unicellular, photo-responsive algae, Euglena gracilis, under light stimulation. By varying the spatiotemporal light patterns, we are able to finely adjust cell densities and achieve arbitrary non-homogeneous distributions, including compression into high-density aggregates of varying geometries. We observe the formation of depletion zones after the release of the confining stimulus and investigate the effects of the density distribution and particle rotational noise on the depletion. These results provide implications for defining state parameters which determine system evolution.

  1. Consistent quantification of climate impacts due to biogenic carbon storage across a range of bio-product systems

    International Nuclear Information System (INIS)

    Guest, Geoffrey; Bright, Ryan M.; Cherubini, Francesco; Strømman, Anders H.

    2013-01-01

    Temporary and permanent carbon storage from biogenic sources is seen as a way to mitigate climate change. The aim of this work is to illustrate the need to harmonize the quantification of such mitigation across all possible storage pools in the bio- and anthroposphere. We investigate nine alternative storage cases and a wide array of bio-resource pools: from annual crops, short rotation woody crops, medium rotation temperate forests, and long rotation boreal forests. For each feedstock type and biogenic carbon storage pool, we quantify the carbon cycle climate impact due to the skewed time distribution between emission and sequestration fluxes in the bio- and anthroposphere. Additional consideration of the climate impact from albedo changes in forests is also illustrated for the boreal forest case. When characterizing climate impact with global warming potentials (GWP), we find a large variance in results which is attributed to different combinations of biomass storage and feedstock systems. The storage of biogenic carbon in any storage pool does not always confer climate benefits: even when biogenic carbon is stored long-term in durable product pools, the climate outcome may still be undesirable when the carbon is sourced from slow-growing biomass feedstock. For example, when biogenic carbon from Norway Spruce from Norway is stored in furniture with a mean life time of 43 years, a climate change impact of 0.08 kg CO 2 eq per kg CO 2 stored (100 year time horizon (TH)) would result. It was also found that when biogenic carbon is stored in a pool with negligible leakage to the atmosphere, the resulting GWP factor is not necessarily − 1 CO 2 eq per kg CO 2 stored. As an example, when biogenic CO 2 from Norway Spruce biomass is stored in geological reservoirs with no leakage, we estimate a GWP of − 0.56 kg CO 2 eq per kg CO 2 stored (100 year TH) when albedo effects are also included. The large variance in GWPs across the range of resource and carbon storage

  2. Consistent quantification of climate impacts due to biogenic carbon storage across a range of bio-product systems

    Energy Technology Data Exchange (ETDEWEB)

    Guest, Geoffrey, E-mail: geoffrey.guest@ntnu.no; Bright, Ryan M., E-mail: ryan.m.bright@ntnu.no; Cherubini, Francesco, E-mail: francesco.cherubini@ntnu.no; Strømman, Anders H., E-mail: anders.hammer.stromman@ntnu.no

    2013-11-15

    Temporary and permanent carbon storage from biogenic sources is seen as a way to mitigate climate change. The aim of this work is to illustrate the need to harmonize the quantification of such mitigation across all possible storage pools in the bio- and anthroposphere. We investigate nine alternative storage cases and a wide array of bio-resource pools: from annual crops, short rotation woody crops, medium rotation temperate forests, and long rotation boreal forests. For each feedstock type and biogenic carbon storage pool, we quantify the carbon cycle climate impact due to the skewed time distribution between emission and sequestration fluxes in the bio- and anthroposphere. Additional consideration of the climate impact from albedo changes in forests is also illustrated for the boreal forest case. When characterizing climate impact with global warming potentials (GWP), we find a large variance in results which is attributed to different combinations of biomass storage and feedstock systems. The storage of biogenic carbon in any storage pool does not always confer climate benefits: even when biogenic carbon is stored long-term in durable product pools, the climate outcome may still be undesirable when the carbon is sourced from slow-growing biomass feedstock. For example, when biogenic carbon from Norway Spruce from Norway is stored in furniture with a mean life time of 43 years, a climate change impact of 0.08 kg CO{sub 2}eq per kg CO{sub 2} stored (100 year time horizon (TH)) would result. It was also found that when biogenic carbon is stored in a pool with negligible leakage to the atmosphere, the resulting GWP factor is not necessarily − 1 CO{sub 2}eq per kg CO{sub 2} stored. As an example, when biogenic CO{sub 2} from Norway Spruce biomass is stored in geological reservoirs with no leakage, we estimate a GWP of − 0.56 kg CO{sub 2}eq per kg CO{sub 2} stored (100 year TH) when albedo effects are also included. The large variance in GWPs across the range of

  3. Release measurement of great amount of waste. Conveyor belt versus wire mesh pallet systems

    Energy Technology Data Exchange (ETDEWEB)

    Sokcic-Kostic, Marina; Schultheis, Roland; Langer, Felix [NUKEM Technologies Engineering Services GmbH, Alzenau (Germany)

    2014-08-15

    Great amount of waste has to be measured for release during the decommissioning and rebuilding of nuclear facilities and installation. Since the enclosed storage or decontamination is very expensive it is advisable for economic reasons to separate contaminated material. The necessary measurement is however a time and cost intensive work which has carefully provided. There are two general methods to perform this task: one is a continuously running system on the basis of a conveyor belt system. The other approach is a discontinuously running system using wire mesh pallets. With the knowledge from existing installations this article will discuss the pro's and contra's and show the limits of the systems.

  4. [Effect of nociceptin on histamine and serotonin release in the central nervous system].

    Science.gov (United States)

    Gyenge, Melinda; Hantos, Mónika; Laufer, Rudolf; Tekes, Korniléa

    2006-01-01

    Role in pain sensation of both nociceptin (NC), the bioactive heptadecapeptide sequence of preproorphaninFQ and of histamine has been widely evidenced in the central nervous system (CNS). In the current series of experiments effect of intracerebroventricularly (i.c.v.) administered NC (5.5 nmol/rat) on histamine and serotonin levels in blood plasma, CSF and brain areas (hypothalamus and hippocampus) was studies and compared to the effect of the mast cell degranulator Compound 48/80(100microg/kg, i.c.v.) and the neuroactive peptide Substance P (50nmol/rat, i.c.v.). It was found that all the three compounds increased the histamine level in the CNS, however their activity concerning the mast cell-, and neuronal histamine release is different. NC could release histamine from both the mast cells and the neurons and it decreased CNS serotonin levels. Substance P was found the most potent in increasing CNS histamine levels. Compound 48/80 treatment resulted in elevated histamine levels both in the CNS and blood plasma. It is concluded that the histamine releasing effects of i.c.v. administered NC and SP are limited to the CNS, but in the effect of Compound 48/80 its blood-brain barrier impairing activity is also involved. Data also demonstrate that NC has significant effect on both the histaminergic and serotonergic neurotransmission in the CNS.

  5. Dynamic microvesicle release and clearance within the cardiovascular system: triggers and mechanisms.

    Science.gov (United States)

    Ayers, Lisa; Nieuwland, Rienk; Kohler, Malcolm; Kraenkel, Nicolle; Ferry, Berne; Leeson, Paul

    2015-12-01

    Interest in cell-derived microvesicles (or microparticles) within cardiovascular diagnostics and therapeutics is rapidly growing. Microvesicles are often measured in the circulation at a single time point. However, it is becoming clear that microvesicle levels both increase and decrease rapidly in response to certain stimuli such as hypoxia, acute cardiac stress, shear stress, hypertriglyceridaemia and inflammation. Consequently, the levels of circulating microvesicles will reflect the balance between dynamic mechanisms for release and clearance. The present review describes the range of triggers currently known to lead to microvesicle release from different cellular origins into the circulation. Specifically, the published data are used to summarize the dynamic impact of these triggers on the degree and rate of microvesicle release. Secondly, a summary of the current understanding of microvesicle clearance via different cellular systems, including the endothelial cell and macrophage, is presented, based on reported studies of clearance in experimental models and clinical scenarios, such as transfusion or cardiac stress. Together, this information can be used to provide insights into potential underlying biological mechanisms that might explain the increases or decreases in circulating microvesicle levels that have been reported and help to design future clinical studies. © 2015 Authors; published by Portland Press Limited.

  6. [Research on controlling iron release of desalted water transmitted in existing water distribution system].

    Science.gov (United States)

    Tian, Yi-Mei; Liu, Yang; Zhao, Peng; Shan, Jin-Lin; Yang, Suo-Yin; Liu, Wei

    2012-04-01

    Desalted water, with strong corrosion characteristics, would possibly lead to serious "red water" when transmitted and distributed in existing municipal water distribution network. The main reason for red water phenomenon is iron release in water pipes. In order to study the methods of controlling iron release in existing drinking water distribution pipe, tubercle analysis of steel pipe and cast iron pipe, which have served the distribution system for 30-40 years, was carried out, the main construction materials were Fe3O4 and FeOOH; and immersion experiments were carried in more corrosive pipes. Through changing mixing volume of tap water and desalted water, pH, alkalinity, chloride and sulfate, the influence of different water quality indexes on iron release were mainly analyzed. Meanwhile, based on controlling iron content, water quality conditions were established to meet with the safety distribution of desalted water: volume ratio of potable water and desalted water should be higher than or equal to 2, pH was higher than 7.6, alkalinity was higher than 200 mg x L(-1).

  7. Glass consistency and glass performance

    International Nuclear Information System (INIS)

    Plodinec, M.J.; Ramsey, W.G.

    1994-01-01

    Glass produced by the Defense Waste Processing Facility (DWPF) will have to consistently be more durable than a benchmark glass (evaluated using a short-term leach test), with high confidence. The DWPF has developed a Glass Product Control Program to comply with this specification. However, it is not clear what relevance product consistency has on long-term glass performance. In this report, the authors show that DWPF glass, produced in compliance with this specification, can be expected to effectively limit the release of soluble radionuclides to natural environments. However, the release of insoluble radionuclides to the environment will be limited by their solubility, and not glass durability

  8. Polonium release from an ATW burner system with liquid lead-bismuth coolant

    International Nuclear Information System (INIS)

    Li, N.; Yefimov, E.; Pankratov, D.

    1998-04-01

    The authors analyzed polonium release hazards in a conceptual pool-type ATW burner with liquid lead-bismuth eutectic (LBE) coolant. Simplified quantitative models are used based on experiments and real NPP experience. They found little Po contamination outside the burner under normal operating conditions with nominal leakage from the gas system. In sudden gas leak and/or coolant spill accidents, the P contamination level can reach above the regulation limit but short exposure would not lead to severe health consequences. They are evaluating and developing mitigation methods

  9. Acoustic mapping of shallow water gas releases using shipborne multibeam systems

    Science.gov (United States)

    Urban, Peter; Köser, Kevin; Weiß, Tim; Greinert, Jens

    2015-04-01

    Water column imaging (WCI) shipborne multibeam systems are effective tools for investigating marine free gas (bubble) release. Like single- and splitbeam systems they are very sensitive towards gas bubbles in the water column, and have the advantage of the wide swath opening angle, 120° or more allowing a better mapping and possible 3D investigations of targets in the water column. On the downside, WCI data are degraded by specific noise from side-lobe effects and are usually not calibrated for target backscattering strength analysis. Most approaches so far concentrated on manual investigations of bubbles in the water column data. Such investigations allow the detection of bubble streams (flares) and make it possible to get an impression about the strength of detected flares/the gas release. Because of the subjective character of these investigations it is difficult to understand how well an area has been investigated by a flare mapping survey and subjective impressions about flare strength can easily be fooled by the many acoustic effects multibeam systems create. Here we present a semi-automated approach that uses the behavior of bubble streams in varying water currents to detect and map their exact source positions. The focus of the method is application of objective rules for flare detection, which makes it possible to extract information about the quality of the seepage mapping survey, perform automated noise reduction and create acoustic maps with quality discriminators indicating how well an area has been mapped.

  10. The ALPS project release 2.0: open source software for strongly correlated systems

    International Nuclear Information System (INIS)

    Bauer, B; Gamper, L; Gukelberger, J; Hehn, A; Isakov, S V; Ma, P N; Mates, P; Carr, L D; Evertz, H G; Feiguin, A; Freire, J; Koop, D; Fuchs, S; Gull, E; Guertler, S; Igarashi, R; Matsuo, H; Parcollet, O; Pawłowski, G; Picon, J D

    2011-01-01

    We present release 2.0 of the ALPS (Algorithms and Libraries for Physics Simulations) project, an open source software project to develop libraries and application programs for the simulation of strongly correlated quantum lattice models such as quantum magnets, lattice bosons, and strongly correlated fermion systems. The code development is centered on common XML and HDF5 data formats, libraries to simplify and speed up code development, common evaluation and plotting tools, and simulation programs. The programs enable non-experts to start carrying out serial or parallel numerical simulations by providing basic implementations of the important algorithms for quantum lattice models: classical and quantum Monte Carlo (QMC) using non-local updates, extended ensemble simulations, exact and full diagonalization (ED), the density matrix renormalization group (DMRG) both in a static version and a dynamic time-evolving block decimation (TEBD) code, and quantum Monte Carlo solvers for dynamical mean field theory (DMFT). The ALPS libraries provide a powerful framework for programmers to develop their own applications, which, for instance, greatly simplify the steps of porting a serial code onto a parallel, distributed memory machine. Major changes in release 2.0 include the use of HDF5 for binary data, evaluation tools in Python, support for the Windows operating system, the use of CMake as build system and binary installation packages for Mac OS X and Windows, and integration with the VisTrails workflow provenance tool. The software is available from our web server at http://alps.comp-phys.org/

  11. An eddy-permitting, dynamically consistent adjoint-based assimilation system for the tropical Pacific: Hindcast experiments in 2000

    KAUST Repository

    Hoteit, Ibrahim; Cornuelle, B.; Heimbach, P.

    2010-01-01

    An eddy-permitting adjoint-based assimilation system has been implemented to estimate the state of the tropical Pacific Ocean. The system uses the Massachusetts Institute of Technology's general circulation model and its adjoint. The adjoint method

  12. The Rucio Consistency Service

    CERN Document Server

    Serfon, Cedric; The ATLAS collaboration

    2016-01-01

    One of the biggest challenge with Large scale data management system is to ensure the consistency between the global file catalog and what is physically on all storage elements. To tackle this issue, the Rucio software which is used by the ATLAS Distributed Data Management system has been extended to automatically handle lost or unregistered files (aka Dark Data). This system automatically detects these inconsistencies and take actions like recovery or deletion of unneeded files in a central manner. In this talk, we will present this system, explain the internals and give some results.

  13. Design of a controlled release system of OP-1 and TGF-β1 based in microparticles of sodium alginate and release characterization by HPLC-UV.

    Science.gov (United States)

    Oliva-Rodríguez, Ricardo; Pérez-Urizar, José; Dibildox-Alvarado, Estela; Martínez-Saldaña, María Consolación; Avelar-González, Francisco Javier; Flores-Reyes, Héctor; Pozos-Guillén, Amaury de Jesús; Guerrero-Barrera, Alma Lilián

    2011-12-01

    A new system for sustained release of growth factors, such as osteogenic protein 1 (OP-1) and transforming growth factor β1 (TGF-β1), intended to repair and promote dental tissue regeneration in rats was designed and characterized in this work. The release system was made with microparticles of sodium alginate, produced by ionic gelling dripping technique. The release profiles of OP-1 and TGF-β1 from biopolymer matrix were determined by high-performance liquid chromatography (HPLC), and with this purpose, an HPLC-UV method was developed. About 80% of each growth factor was released in the first 24 h, reaching almost 100% in 168 h. The system was tested during the tissue repair in rat molars in comparison with calcium hydroxide and both growth factors not encapsulated. The dentin sialoprotein (DSP) was used as a repair marker. It was detected by immunohistochemistry, after 14- and 28-d post-treatment. X (2) test (p ≤ 0.001) and Fisher exact test (p ≤ 0.05) were applied for assessment of the amount of immunostaining. The treatment with encapsulated OP-1 showed an increased DSP immunostaining after 14 d and did not find any significant difference with the immunostaining observed for calcium hydroxide treatment. Treatment with TGF-β1 did not show significant difference with calcium hydroxide. Treatment with both factors OP-1 and TGF-β1 showed higher DSP immunostaining in comparison with calcium hydroxide treatment. In conclusion, the combination of both growth factors encapsulated showed more DSP immunostaining in comparison with each one separated, either encapsulated or not.

  14. Status of emission release and associated problems in energy systems analysis

    International Nuclear Information System (INIS)

    Yasukawa, Shigeru; Mankin, Shuichi; Sato, Osamu; Koyama, Shigeo; Ihara, Seijiro.

    1987-11-01

    OECD/IEA/ETSAP (Energy Technology System Analysis Project) has been started in March 1976. Since initiation of the projects, JAERI and ETL (Electrotechnical Laboratory) have been participating in the projects as operating agent of Japan. From last October, the ETSAP has initiated its Annex III programme, which pursues the problems laid down in energy-environment relationships. Main research objective of the programme is to investigate through the systems analysis ''how various environmental constrains would affect the pattern of fuel and technology use and the choice and timing of implementation of abatement technologies''. In this report, we describe the status of emission release in Japan and associated problems in energy system analysis which has been investigated at the start of these research programme mentioned above. (author)

  15. Biomaterial-based drug delivery systems for the controlled release of neurotrophic factors

    International Nuclear Information System (INIS)

    Mohtaram, Nima Khadem; Montgomery, Amy; Willerth, Stephanie M

    2013-01-01

    This review highlights recent work on the use of biomaterial-based drug delivery systems to control the release of neurotrophic factors as a potential strategy for the treatment of neurological disorders. Examples of neurotrophic factors include the nerve growth factor, the glial cell line-derived neurotrophic factor, the brain-derived neurotrophic factor and neurotrophin-3. In particular, this review focuses on two methods of drug delivery: affinity-based and reservoir-based systems. We review the advantages and challenges associated with both types of drug delivery system and how these systems can be applied to neurological diseases and disorders. While a limited number of affinity-based delivery systems have been developed for the delivery of neurotrophic factors, we also examine the broad spectrum of reservoir-based delivery systems, including microspheres, electrospun nanofibers, hydrogels and combinations of these systems. Finally, conclusions are drawn about the current state of such drug delivery systems as applied to neural tissue engineering along with some thoughts on the future direction of the field. (topical review)

  16. TURVA-2012: Assessment of radionuclide release scenarios for the repository system

    International Nuclear Information System (INIS)

    Smith, Paul; Poteri, Antti; Nordman, Henrik; Cormenzana, Jose Luis; Snellman, Margit; Marcos, Nuria; Hjerpe, Thomas; Koskinen, Lasse

    2014-01-01

    TURVA-2012 is Posiva's safety case in support of the Preliminary Safety Analysis Report (PSAR) and application for a construction licence for a repository for disposal of spent nuclear fuel at the Olkiluoto site in south-western Finland. This paper gives a summary of the analyses of the radionuclide release scenarios formulated in a companion paper, TURVA-2012: Formulation of Radionuclide Release Scenarios (Marcos, 2014). The scenarios and the analyses take into account major uncertainties in the initial state of the barriers and possible paths for the evolution of the repository system identified in a further paper: TURVA-2012: Performance Assessment (Hellae, 2014). For each scenario, calculation cases are analysed to evaluate compliance of the proposed repository with regulatory requirements on radiological protection, as well as to illustrate the impact of specific uncertainties or combinations of uncertainties on the calculated results. Each case illustrates different possibilities for how the repository might evolve and perform over time, taking into account uncertainties in the models and parameter values used to represent radionuclide release, retention and transport and, for biosphere assessment calculation cases, radiation exposure. The calculation cases each address a single, failed canister, where three possible modes of failure are considered: - The presence of an initial defect in the copper overpack of the canister that penetrates the overpack completely (subsequent corrosion of the insert may then lead to an enlargement of the defect). - Corrosion of the copper overpack, which occurs most rapidly in scenarios in which buffer density is reduced, e.g. by erosion. - Shear movements on fractures intersecting the deposition holes. However, the likelihood and consequences of more than one canister failure occurring during the assessment time fame are also considered, generally based on the findings from the single canister calculations. Quantitative

  17. Reducing Mortality from Terrorist Releases of Chemical and Biological Agents: I. Filtration for Ventilation Systems in Commercial Building

    Energy Technology Data Exchange (ETDEWEB)

    Thatcher, Tracy L.; Daisey, Joan M.

    1999-09-01

    There is growing concern about potential terrorist attacks involving releases of chemical and/or biological (CB) agents, such as sarin or anthrax, in and around buildings. For an external release, the CB agent can enter the building through the air intakes of a building's mechanical ventilation system and by infiltration through the building envelope. For an interior release in a single room, the mechanical ventilation system, which often recirculates some fraction of the air within a building, may distribute the released CB agent throughout the building. For both cases, installing building systems that remove chemical and biological agents may be the most effective way to protect building occupants. Filtration systems installed in the heating, ventilating and air-conditioning (HVAC) systems of buildings can significantly reduce exposures of building occupants in the event of a release, whether the release is outdoors or indoors. Reduced exposures can reduce the number of deaths from a terrorist attack. The purpose of this report is to provide information and examples of the design of filtration systems to help building engineers retrofit HVAC systems. The report also provides background information on the physical nature of CB agents and brief overviews of the basic principles of particle and vapor filtration.

  18. Preparation and characterization of ibuprofen-loaded microspheres consisting of poly(3-hydroxybutyrate) and methoxy poly (ethylene glycol)-b-poly (D,L-lactide) blends or poly(3-hydroxybutyrate) and gelatin composites for controlled drug release

    Energy Technology Data Exchange (ETDEWEB)

    Bidone, Juliana; Melo, Ana Paula P. [Laboratorio de Farmacotecnica, Departamento de Ciencias Farmaceuticas, Universidade Federal de Santa Catarina, Florianopolis (Brazil); Bazzo, Giovana C. [Grupo de Estudos em Materiais Polimericos (POLIMAT), Departamento de Quimica, Universidade Federal de Santa Catarina, Florianopolis (Brazil); Carmignan, Francoise [Laboratorio de Farmacotecnica, Departamento de Ciencias Farmaceuticas, Universidade Federal de Santa Catarina, Florianopolis (Brazil); Soldi, Marli S.; Pires, Alfredo T.N. [Grupo de Estudos em Materiais Polimericos (POLIMAT), Departamento de Quimica, Universidade Federal de Santa Catarina, Florianopolis (Brazil); Lemos-Senna, Elenara [Laboratorio de Farmacotecnica, Departamento de Ciencias Farmaceuticas, Universidade Federal de Santa Catarina, Florianopolis (Brazil)], E-mail: lemos@ccs.ufsc.br

    2009-03-01

    Poly-(3-hydroxybutyrate) (P(3HB)) is a biodegradable and biocompatible polymer that has been used to obtain polymer-based drug carriers. However, due to the high crystallinity degree of this polymer, drug release from P(3HB) microspheres frequently occurs at excessive rates. In this study, two strategies for prolonging ibuprofen release from P(3HB)-based microspheres were tested: blending with poly(D,L-lactide)-b-polyethylene glycol (mPEG-PLA); and obtaining composite particles with gelatin (GEL). SEM micrographs showed particles that were spherical and had a rough surface. A slight decrease of the crystallinity degree of P(3HB) was observed only in the DSC thermogram obtained from unloaded-microspheres prepared from 1:1 P(3HB):mPEG-PLA blend. For IBF-loaded microspheres, a reduction of around 10 deg. C in the melting temperature of P(3HB) was observed, indicating that the crystalline structure of the polymer was affected in the presence of the drug. DSC studies also yielded evidence of the presence of a molecular dispersion coexisting with a crystalline dispersion in the drug in the matrix. Similar results were obtained from X-ray diffractograms. In spite of 1:1 mPEG-PLA:P(3HB) blends having contributed to the reduction of the burst effect, a more controlled drug release was provided by the use of the 3:1 P(3HB):mPEGPLA blend. This result indicated that particle hydration played an important role in the drug release. On the other hand, the preparation of P(3HB):GEL composite microspheres did not allow control of the IBF release.

  19. Preparation and characterization of ibuprofen-loaded microspheres consisting of poly(3-hydroxybutyrate) and methoxy poly (ethylene glycol)-b-poly (D,L-lactide) blends or poly(3-hydroxybutyrate) and gelatin composites for controlled drug release

    International Nuclear Information System (INIS)

    Bidone, Juliana; Melo, Ana Paula P.; Bazzo, Giovana C.; Carmignan, Francoise; Soldi, Marli S.; Pires, Alfredo T.N.; Lemos-Senna, Elenara

    2009-01-01

    Poly-(3-hydroxybutyrate) (P(3HB)) is a biodegradable and biocompatible polymer that has been used to obtain polymer-based drug carriers. However, due to the high crystallinity degree of this polymer, drug release from P(3HB) microspheres frequently occurs at excessive rates. In this study, two strategies for prolonging ibuprofen release from P(3HB)-based microspheres were tested: blending with poly(D,L-lactide)-b-polyethylene glycol (mPEG-PLA); and obtaining composite particles with gelatin (GEL). SEM micrographs showed particles that were spherical and had a rough surface. A slight decrease of the crystallinity degree of P(3HB) was observed only in the DSC thermogram obtained from unloaded-microspheres prepared from 1:1 P(3HB):mPEG-PLA blend. For IBF-loaded microspheres, a reduction of around 10 deg. C in the melting temperature of P(3HB) was observed, indicating that the crystalline structure of the polymer was affected in the presence of the drug. DSC studies also yielded evidence of the presence of a molecular dispersion coexisting with a crystalline dispersion in the drug in the matrix. Similar results were obtained from X-ray diffractograms. In spite of 1:1 mPEG-PLA:P(3HB) blends having contributed to the reduction of the burst effect, a more controlled drug release was provided by the use of the 3:1 P(3HB):mPEGPLA blend. This result indicated that particle hydration played an important role in the drug release. On the other hand, the preparation of P(3HB):GEL composite microspheres did not allow control of the IBF release

  20. Development and Validation of a National System for Routine Monitoring of Mortality in People Recently Released from Prison.

    Directory of Open Access Journals (Sweden)

    Stuart A Kinner

    Full Text Available People released from prison are at increased risk of death. However, no country has established a system for routine monitoring of mortality in this population. The aims of this study were to (a evaluate a system for routine monitoring of deaths after release from prison in Australia and (b estimate the number of deaths annually within 28 and 365 days of prison release from 2000 to 2013.Persons released from prison and deaths were identified in records held by Centrelink, Australia's national provider of unemployment benefits. Estimates generated in this manner were compared with those from a study that probabilistically linked correctional records with the National Death Index (NDI, for each calendar year 2000 to 2007. Using Centrelink data, national estimates of mortality within 28 and 365 days of release were produced for each calendar year 2000 to 2013.Compared with estimates based on linkage with the NDI, the estimated crude mortality rate based on Centrelink records was on average 52% lower for deaths within 28 days of release and 24% lower for deaths within 365 days of release. Nationally, over the period 2000 to 2013, we identified an average of 32 deaths per year within 28 days of release and 188 deaths per year within 365 days of release. The crude mortality rate for deaths within both 28 and 365 days of release increased over this time.Using routinely collected unemployment benefits data we detected the majority of deaths in people recently released from prison in Australia. These data may be sufficient for routine monitoring purposes and it may be possible to adopt a similar approach in other countries. Routine surveillance of mortality in ex-prisoners serves to highlight their extreme vulnerability and provides a basis for evaluating policy reforms designed to reduce preventable deaths.

  1. Aerial release of Rhinoncomimus latipes (Coleoptera: Curculionidae) to control Persicaria perfoliata (Polygonaceae) using an unmanned aerial system.

    Science.gov (United States)

    Park, Yong-Lak; Gururajan, Srikanth; Thistle, Harold; Chandran, Rakesh; Reardon, Richard

    2018-01-01

    Rhinoncomimus latipes (Coleoptera: Curculionidae) is a major biological control agent against the invasive plant Persicaria perfoliata. Release of R. latipes is challenging with the current visit-and-hand release approach because P. perfoliata shows a high degree of patchiness in the landscape, possesses recurved barbs on its stems, and often spreads into hard-to-access areas. This 3-year study developed and evaluated unmanned aerial systems (UAS) for precise aerial release of R. latipes to control P. perfoliata. We have developed two UAS (i.e. quad-rotor and tri-rotor) and an aerial release system to disseminate R. latipes. These include pods containing R. latipes and a dispenser to accommodate eight pods. Results of field tests to evaluate the systems showed no significant (P > 0.05) effects on survivorship and feeding ability of R. latipes after aerial release. Our study demonstrates the potential of UAS for precision aerial release of biological control agents to control invasive plants. The aerial deployment systems we have developed, including both pods and a dispenser, are low cost, logistically practical, and effective with no negative effects on aerially released R. latipes. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  2. Effect of ca2+ to salicylic acid release in pectin based controlled drug delivery system

    Science.gov (United States)

    Kistriyani, L.; Wirawan, S. K.; Sediawan, W. B.

    2016-01-01

    Wastes from orange peel are potentially be utilized to produce pectin, which are currently an import commodity. Pectin can be used in making edible film. Edible films are potentially used as a drug delivery system membrane after a tooth extraction. Drug which is used in the drug delivery system is salicylic acid. It is an antiseptic. In order to control the drug release rate, crosslinking process is added in the manufacturing of membrane with CaCl2.2H2O as crosslinker. Pectin was diluted in water and mixed with a plasticizer and CaCl2.2H2O solution at 66°C to make edible film. Then the mixture was dried in an oven at 50 °C. After edible film was formed, it was coated using plasticizer and CaCl2.2H2O solution with various concentration 0, 0.015, 0.03 and 0.05g/mL. This study showed that the more concentration of crosslinker added, the slower release of salicylic acid would be. This was indicated by the value of diffusivites were getting smaller respectively. The addition of crosslinker also caused smaller gels swelling value,which made the membrane is mechanically stronger

  3. Systemic release of cytokines and heat shock proteins in porcine models of polytrauma and hemorrhage

    Science.gov (United States)

    Baker, Todd A.; Romero, Jacqueline; Bach, Harold H.; Strom, Joel A.; Gamelli, Richard L.; Majetschak, Matthias

    2011-01-01

    Objective To define systemic release kinetics of a panel of cytokines and heat shock proteins (HSP) in porcine polytrauma/hemorrhage models and to evaluate whether they could be useful as early trauma biomarkers. Design and Setting Prospective study in a research laboratory. Subjects Twenty-one Yorkshire pigs. Measurements and Main Results Pigs underwent polytrauma (femur fractures/lung contusion, P), hemorrhage (mean arterial pressure 25-30mmHg, H), polytrauma plus hemorrhage (P/H) or sham procedure (S). Plasma was obtained at baseline, in 5-15min intervals during a 60min shock period without intervention and in 60-120min intervals during fluid resuscitation for up to 300min. Plasma was assayed for IL-1β, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12/IL-23p40, IL-13, IL-17, IL-18, IFNγ, TGFβ, TNFα, HSP40, HSP70 and HSP90 by ELISA. All animals after S, P and H survived (n=5/group). Three of six animals after P/H died. IL-10 increased during shock after P and this increase was attenuated after H. TNFα increased during the shock period after P, H and also after S. P/H abolished the systemic IL-10 and TNFα release and resulted in 20-30% increased levels of IL-6 during shock. As fluid resuscitation was initiated TNFα and IL-10 levels decreased after P, H and P/H, HSP 70 increased after P, IL-6 levels remained elevated after P/H and also increased after P and S. Conclusions Differential regulation of the systemic cytokine release after polytrauma and/or hemorrhage, in combination with the effects of resuscitation, can explain the variability and inconsistent association of systemic cytokine/HSP levels with clinical variables in trauma patients. Insults of major severity (P/H) partially suppress the systemic inflammatory response. The plasma concentrations of the measured cytokines/HSPs do not reflect injury severity or physiological changes in porcine trauma models and are unlikely to be able to serve as useful trauma biomarkers in patients. PMID:21983369

  4. Conductive polymers for controlled release and treatment of central nervous system injury

    Science.gov (United States)

    Saigal, Rajiv

    As one of the most devastating forms of neurotrauma, spinal cord injury remains a challenging clinical problem. The difficulties in treatment could potentially be resolved by better technologies for therapeutic delivery. In order to develop new approaches to treating central nervous system injury, this dissertation focused on using electrically-conductive polymers, controlled drug release, and stem cell transplantation. We first sought to enhance the therapeutic potential of neural stem cells by electrically increasing their production of neurotrophic factors (NTFs), important molecules for neuronal cell survival, differentiation, synaptic development, plasticity, and growth. We fabricated a new cell culture device for growing neural stem cells on a biocompatible, conductive polymer. Electrical stimulation via the polymer led to upregulation of NTF production by neural stem cells. This approach has the potential to enhance stem cell function while avoiding the pitfalls of genetic manipulation, possibly making stem cells more viable as a clinical therapy. Seeing the therapeutic potential of conductive polymers, we extended our studies to an in vivo model of spinal cord injury (SCI). Using a novel fabrication and extraction technique, a conductive polymer was fabricated to fit to the characteristic pathology that follows contusive SCI. Assessed via quantitative analysis of MR images, the conductive polymer significantly reduced compression of the injured spinal cord. Further characterizing astroglial and neuronal response of injured host tissue, we found significant neuronal sparing as a result of this treatment. The in vivo studies also demonstrated improved locomotor recovery mediated by a conductive polymer scaffold over a non-conductive control. We next sought to take advantage of conductive polymers for local, electronically-controlled release of drugs. Seeking to overcome reported limitations in drug delivery via polypyrrole, we first embedded drugs in poly

  5. Feasibility study of an islanded microgrid in rural area consisting of PV, wind, biomass and battery energy storage system

    International Nuclear Information System (INIS)

    Singh, Shakti; Singh, Mukesh; Kaushik, Subhash Chandra

    2016-01-01

    Highlights: • A cost effective hybrid PV-wind-biomass energy system with storage is proposed. • Mathematical modeling and operational strategy of the proposed system is discussed. • Optimal sizing of components is evaluated using evolutionary algorithms. • Results obtained is compared with software tool HOMER. • The performance of the hybrid system in the critical case has been presented. - Abstract: Renewable energy systems are proving to be promising and environment friendly sources of electricity generation, particularly, in countries with inadequate fossil fuel resources. In recent years, wind, solar photovoltaic (PV) and biomass based systems have been drawing more attention to provide electricity to isolated or energy deficient regions. This paper presents a hybrid PV-wind generation system along with biomass and storage to fulfill the electrical load demand of a small area. For optimal sizing of components, a recently introduced swarm based artificial bee colony (ABC) algorithm is applied. To verify the strength of the proposed technique, the results are compared with the results obtained from the standard software tool, hybrid optimization model for electric renewable (HOMER) and particle swarm optimization (PSO) algorithm. It has been verified from the results that the ABC algorithm has good convergence property and ability to provide good quality results. Further, for critical case such as the failure of any source, the behavior of the proposed system has been observed. It is evident from the results that the proposed scheme is able to manage a smooth power flow with the same optimal configuration.

  6. Early alveolar and systemic mediator release in patients at different risks for ARDS after multiple trauma.

    Science.gov (United States)

    Raymondos, Konstantinos; Martin, Michael U; Schmudlach, Tanja; Baus, Stefan; Weilbach, Christian; Welte, Tobias; Krettek, Christian; Frink, Michael; Hildebrand, Frank

    2012-02-01

    Alveolar IL-8 has been reported to early identify patients at-risk to develop ARDS. However, it remains unknown how alveolar IL-8 is related to pulmonary and systemic inflammation in patients predisposed for ARDS. We studied 24 patients 2-6h after multiple trauma. Patients with IL-8 >200 pg/ml in bronchoalveolar lavage (BAL) were assigned to the group at high risk for ARDS (H, n = 8) and patients with BAL IL-8 mediators. The enhanced alveolar and systemic inflammation associated with alveolar IL-8 release should be considered to identify high-risk patients for pulmonary complications after multiple trauma to adjust surgical and other treatment strategies to the individual risk profile. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Intricacies of Using Kevlar and Thermal Knives in a Deployable Release System: Issues and Solutions

    Science.gov (United States)

    Stewart, Alphonso C.; Hair, Jason H.; Broduer, Steve (Technical Monitor)

    2002-01-01

    The utilization of Kevlar cord and thermal knives in a deployable release system produces a number of issues that must be addressed in the design of the system. This paper proposes design considerations that minimize the major issues, thermal knife failure, Kevlar cord relaxation, and the measurement of the cord tension. Design practices can minimize the potential for thermal knife laminate and element damage that result in failure of the knife. A process for in-situ inspection of the knife with resistance, rather than continuity, checks and 10x zoom optical imaging can detect damaged knives. Tests allow the characterization of the behavior of the particular Kevlar cord in use and the development of specific pre-stretching techniques and initial tension values needed to meet requirements. A new method can accurately measure the tension of the Kevlar cord using a guitar tuner, because more conventional methods do not apply to arimid cords such as Kevlar.

  8. Intricacies of Using Kevlar Cord and Thermal Knives in a Deployable Release System: Issues and Solutions

    Science.gov (United States)

    Stewart, Alphonso; Hair, Jason H.

    2002-01-01

    The utilization of Kevlar cord and thermal knives in a deployable release system produces a number of issues that must be addressed in the design of the system. This paper proposes design considerations that minimize the major issues, thermal knife failure, Kevlar cord relaxation, and the measurement of the cord tension. Design practices can minimize the potential for thermal knife laminate and element damage that result in failure of the knife. A process for in-situ inspection of the knife with resistance, rather than continuity, checks and 10x zoom optical imaging can detect damaged knives. Tests allow the characterization of the behavior of the particular Kevlar cord in use and the development of specific prestretching techniques and initial tension values needed to meet requirements. A new method can accurately measure the tension of the Kevlar cord using a guitar tuner, because more conventional methods do not apply to arimid cords such as Kevlar.

  9. Blends of PHB/PEG: obtention of matrices for use as controlled drug release systems

    International Nuclear Information System (INIS)

    Catoni, S.E.M.; Gomes, C.A.T.; Trindade, K.N.S.; Schneider, A.L.S.; Pezzin, A.P.T.; Soldi, V.

    2010-01-01

    Different materials have been used in the development of micro-and nanostructured systems for drug release. In general, poly(3-hydroxybutyrate) (PHB) matrixes have high crystallinity degree, justifying its slow degradation. This feature makes the attack of enzymes more difficult. Thus, the surface modification with hydrophilic polymers such as poly(ethylene glycol) (PEG) has been investigated in order to obtain particles which are not recognized and captured by phagocytic cells after in vivo administration, staying for a longer in the systemic circulation. In this work, PHB/PEG films were prepared by casting in different proportions and characterized by XRD, DSC, SEM, GPC and TGA. The films presented high crystallinity degree and showed uniformity, except the 50/50 composition which showed the presence of two phases. The results revealed that increasing percentage of PEG, the Tm of PHB was decreased, the thermal stability was dramatically decreased and molecular weight of the samples was lower. (author)

  10. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  11. Status, recent developments and perspective of TINE-powered video system, release 3

    International Nuclear Information System (INIS)

    Weisse, S.; Melkumyan, D.; Duval, P.

    2012-01-01

    Experience has shown that imaging software and hardware installations at accelerator facilities needs to be changed, adapted and updated on a semi-permanent basis. On this premise the component-based core architecture of Video System 3 was founded. In design and implementation, emphasis was, is, and will be put on flexibility, performance, low latency, modularity, inter operability, use of open source, ease of use as well as reuse, good documentation and multi-platform capability. In the past year, a milestone was reached as Video System 3 entered production-level at PITZ, Hasylab and PETRA III. Since then, the development path has been more strongly influenced by production-level experience and customer feedback. In this contribution, we describe the current status, layout, recent developments and perspective of the Video System. Focus will be put on integration of recording and playback of video sequences to Archive/DAQ, a standalone installation of the Video System on a notebook as well as experiences running on Windows 7-64 bit. In addition, new client-side multi-platform GUI/application developments using Java are about to hit the surface. Last but not least it must be mentioned that although the implementation of Release 3 is integrated into the TINE control system, it is modular enough so that integration into other control systems can be considered. (authors)

  12. Integration of financial and management accounting systems : the mediating influence of a consistent financial language on controllership effectiveness

    OpenAIRE

    Weißenberger, Barbara E.; Angelkort, Hendrik

    2009-01-01

    To provide accounting information for management control purposes, two fundamental options exist: (a) The financial records can be used as a database for management accounting (integrated accounting system design), or (b) the management accounting system used by controllers can be based upon a so-called third set of books besides the financial and tax accounting records. Whereas the latter approach had been typical for firms in German-speaking countries until the 1980s, since then an increasi...

  13. Evaluating the systemic right ventricle by CMR: the importance of consistent and reproducible delineation of the cavity

    Directory of Open Access Journals (Sweden)

    van Dijk Arie PJ

    2008-08-01

    Full Text Available Abstract Background The method used to delineate the boundary of the right ventricle (RV, relative to the trabeculations and papillary muscles in cardiovascular magnetic resonance (CMR ventricular volume analysis, may matter more when these structures are hypertrophied than in individuals with normal cardiovascular anatomy. This study aimed to compare two methods of cavity delineation in patients with systemic RV. Methods Twenty-nine patients (mean age 34.7 ± 12.4 years with a systemic RV (12 with congenitally corrected transposition of the great arteries (ccTGA and 17 with atrially switched (TGA underwent CMR. We compared measurements of systemic RV volumes and function using two analysis protocols. The RV trabeculations and papillary muscles were either included in the calculated blood volume, the boundary drawn immediately within the apparently compacted myocardial layer, or they were manually outlined and excluded. RV stroke volume (SV calculated using each method was compared with corresponding left ventricular (LV SV. Additionally, we compared the differences in analysis time, and in intra- and inter-observer variability between the two methods. Paired samples t-test was used to test for differences in volumes, function and analysis time between the two methods. Differences in intra- and inter-observer reproducibility were tested using an extension of the Bland-Altman method. Results The inclusion of trabeculations and papillary muscles in the ventricular volume resulted in higher values for systemic RV end diastolic volume (mean difference 28.7 ± 10.6 ml, p Conclusion The choice of method for systemic RV cavity delineation significantly affected volume measurements, given the CMR acquisition and analysis systems used. We recommend delineation outside the trabeculations for routine clinical measurements of systemic RV volumes as this approach took less time and gave more reproducible measurements.

  14. Formulation, release characteristics, and bioavailability study of gastroretentive floating matrix tablet and floating raft system of Mebeverine HCl.

    Science.gov (United States)

    El Nabarawi, Mohamed A; Teaima, Mahmoud H; Abd El-Monem, Rehab A; El Nabarawy, Nagla A; Gaber, Dalia A

    2017-01-01

    To prolong the residence time of dosage forms within the gastrointestinal tract until all drug is released at the desired rate is one of the real challenges for oral controlled-release drug delivery systems. This study was designed to develop a controlled-release floating matrix tablet and floating raft system of Mebeverine HCl (MbH) and evaluate different excipients for their floating behavior and in vitro controlled-release profiles. Oral pharmacokinetics of the optimum matrix tablet, raft system formula, and marketed Duspatalin ® 200 mg retard as reference were studied in beagle dogs. The optimized tablet formula (FT-10) and raft system formula (FRS-11) were found to float within 34±5 sec and 15±7 sec, respectively, and both remain buoyant over a period of 12 h in simulated gastric fluid. FT-10 (Compritol/HPMC K100M 1:1) showed the slowest drug release among all prepared tablet formulations, releasing about 80.2% of MbH over 8 h. In contrast, FRS-11 (Sodium alginate 3%/HPMC K100M 1%/Precirol 2%) had the greatest retardation, providing sustained release of 82.1% within 8 h. Compared with the marketed MbH product, the C max of FT-10 was almost the same, while FRS-11 maximum concentration was higher. The t max was 3.33, 2.167, and 3.0 h for marketed MbH product, FT-10, and FRS-11, respectively. In addition, the oral bioavailability experiment showed that the relative bioavailability of the MbH was 104.76 and 116.01% after oral administration of FT-10 and FRS-11, respectively, compared to marketed product. These results demonstrated that both controlled-released floating matrix tablet and raft system would be promising gastroretentive delivery systems for prolonging drug action.

  15. SPEAR-BETA fuel-performance code system: fission-gas-release module. Final report

    International Nuclear Information System (INIS)

    Christensen, R.

    1983-03-01

    The original SPEAR-BETA general description manual covers both mechanistic and statistical models for fuel reliability, but only mechanistic modeling of fission gas release. This addendum covers the SPEAR-BETA statistical model for fission gas release

  16. Non-Pyrotechnic Latch and Release System for Aerospace and Other Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — American remote Vision Company (ARVC) will continue to research and develop a new non-pryotechnic latch and release sytem for use in servicing and flight release...

  17. Tailored release drug delivery system for rifampicin and isoniazid for enhanced bioavailability of rifampicin.

    Science.gov (United States)

    Avachat, Amelia M; Bhise, Satish B

    2011-04-01

    The front line antitubercular drugs rifampicin (RMP) and isoniazid (INH), when co-administered, face the problem of reduced bioavailability of RMP. Stabilization of RMP in the presence of INH under acidic environment may improve the bioavailability of RMP. In vitro degradation studies showed around 15-25% degradation of RMP under the aforesaid conditions if the ratio of RMP: INH is above 1:0.5.This degradation is reduced to less than 10% when the ratio of RMP: INH is below 1:0.25. Based on these findings, an innovative drug delivery system was designed with the immediate release of RMP and tailored prolonged release of INH. The bilayer tablets prepared with this concept were subjected to relative bioavailability studies in healthy human volunteers in an open label, balanced, randomized, single-dose, cross-over study under fasted state. A validated LC-MS/MS bioanalytical method was employed for estimation of RMP and INH in plasma. Bioavailability studies revealed that C(max) and AUC for RMP increased by 18 and 20%, respectively, confirming the above innovative concept. Even in the case of INH, AUC increased significantly by around 30% and thus time above minimum inhibitory concentration (MIC) would also increase, which may result in further improved clinical outcome.

  18. Stepwise encapsulation and controlled two-stage release system for cis-Diamminediiodoplatinum

    Directory of Open Access Journals (Sweden)

    Chen Y

    2014-06-01

    Full Text Available Yun Chen,1,* Qian Li,1,2,* Qingsheng Wu1 1Department of Chemistry, Key Laboratory of Yangtze River Water Environment, Ministry of Education, Tongji University, Shanghai; 2Shanghai Institute of Quality Inspection and Technical Research, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: cis-Diamminediiodoplatinum (cis-DIDP is a cisplatin-like anticancer drug with higher anticancer activity, but lower stability and price than cisplatin. In this study, a cis-DIDP carrier system based on micro-sized stearic acid was prepared by an emulsion solvent evaporation method. The maximum drug loading capacity of cis-DIDP-loaded solid lipid nanoparticles was 22.03%, and their encapsulation efficiency was 97.24%. In vitro drug release in phosphate-buffered saline (pH =7.4 at 37.5°C exhibited a unique two-stage process, which could prove beneficial for patients with tumors and malignancies. MTT (3-[4,5-dimethylthiazol-2-yl]-2, 5-diphenyltetrazolium bromide assay results showed that cis-DIDP released from cis-DIDP-loaded solid lipid nanoparticles had better inhibition activity than cis-DIDP that had not been loaded. Keywords: stearic acid, emulsion solvent evaporation method, drug delivery, cis-DIDP, in vitro

  19. The Multimedia Environmental Pollutant Assessment System (MEPAS)reg-sign: Source-term release formulations

    International Nuclear Information System (INIS)

    Streile, G.P.; Shields, K.D.; Stroh, J.L.; Bagaasen, L.M.; Whelan, G.; McDonald, J.P.; Droppo, J.G.; Buck, J.W.

    1996-11-01

    This report is one of a series of reports that document the mathematical models in the Multimedia Environmental Pollutant Assessment System (MEPAS). Developed by Pacific Northwest National Laboratory for the US Department of Energy, MEPAS is an integrated impact assessment software implementation of physics-based fate and transport models in air, soil, and water media. Outputs are estimates of exposures and health risk assessments for radioactive and hazardous pollutants. Each of the MEPAS formulation documents covers a major MEPAS component such as source-term, atmospheric, vadose zone/groundwater, surface water, and health exposure/health impact assessment. Other MEPAS documentation reports cover the sensitivity/uncertainty formulations and the database parameter constituent property estimation methods. The pollutant source-term release component is documented in this report. MEPAS simulates the release of contaminants from a source, transport through the air, groundwater, surface water, or overland pathways, and transfer through food chains and exposure pathways to the exposed individual or population. For human health impacts, risks are computed for carcinogens and hazard quotients for noncarcinogens. MEPAS is implemented on a desktop computer with a user-friendly interface that allows the user to define the problem, input the required data, and execute the appropriate models for both deterministic and probabilistic analyses

  20. Recent Advances in Stimuli-Responsive Release Function Drug Delivery Systems for Tumor Treatment

    Directory of Open Access Journals (Sweden)

    Chendi Ding

    2016-12-01

    Full Text Available Benefiting from the development of nanotechnology, drug delivery systems (DDSs with stimuli-responsive controlled release function show great potential in clinical anti-tumor applications. By using a DDS, the harsh side effects of traditional anti-cancer drug treatments and damage to normal tissues and organs can be avoided to the greatest extent. An ideal DDS must firstly meet bio-safety standards and secondarily the efficiency-related demands of a large drug payload and controlled release function. This review highlights recent research progress on DDSs with stimuli-responsive characteristics. The first section briefly reviews the nanoscale scaffolds of DDSs, including mesoporous nanoparticles, polymers, metal-organic frameworks (MOFs, quantum dots (QDs and carbon nanotubes (CNTs. The second section presents the main types of stimuli-responsive mechanisms and classifies these into two categories: intrinsic (pH, redox state, biomolecules and extrinsic (temperature, light irradiation, magnetic field and ultrasound ones. Clinical applications of DDS, future challenges and perspectives are also mentioned.

  1. LITERATURE REVIEW: HEAT TRANSFER THROUGH TWO-PHASE INSULATION SYSTEMS CONSISTING OF POWDERS IN A CONTINUOUS GAS PHASE

    Science.gov (United States)

    The report, a review of the literature on heat flow through powders, was motivated by the use of fine powder systems to produce high thermal resistivities (thermal resistance per unit thickness). he term "superinsulations" has been used to describe this type of material, which ha...

  2. An historically consistent and broadly applicable MRV system based on LiDAR sampling and Landsat time-series

    Science.gov (United States)

    W. Cohen; H. Andersen; S. Healey; G. Moisen; T. Schroeder; C. Woodall; G. Domke; Z. Yang; S. Stehman; R. Kennedy; C. Woodcock; Z. Zhu; J. Vogelmann; D. Steinwand; C. Huang

    2014-01-01

    The authors are developing a REDD+ MRV system that tests different biomass estimation frameworks and components. Design-based inference from a costly fi eld plot network was compared to sampling with LiDAR strips and a smaller set of plots in combination with Landsat for disturbance monitoring. Biomass estimation uncertainties associated with these different data sets...

  3. International safeguards data management system. System description: Version 1.1.; Release PLI 82

    International Nuclear Information System (INIS)

    Argentesi, T.; Casilli, T.; Costantini, L.; Dondi, M.G.; Franklin, M.

    1982-01-01

    This document describes a nuclear material accountancy system which has been developed using the ADABAS data base management system and is implemented on the JRC-Ispra computer. Throughout the report, the data base system is referred to as ''ISADAM'', i.e. International Safeguards Data Management System. The system provides tools for a safeguards authority to decide whether an operators MUF (Material Unaccounted For) can be accounted for as an accumulation of operator measurement errors. The principle objective of the applications programs described here is to provide a variance analysis of MUF in which the variance of MUF is computed as a function of the accounting declarations and the error characteristics of the operator measurement system. A overview of ISADAM is presented; then, a detailed description of the processing applied by the system is given. A description of the parameter information required by the four autonomous programs ISADAM is presented. In developing ISADAM, one of the prime factors taken into consideration was the ease with which it could be used

  4. Gel/Space Ratio Evolution in Ternary Composite System Consisting of Portland Cement, Silica Fume, and Fly Ash.

    Science.gov (United States)

    Wu, Mengxue; Li, Chen; Yao, Wu

    2017-01-11

    In cement-based pastes, the relationship between the complex phase assemblage and mechanical properties is usually described by the "gel/space ratio" descriptor. The gel/space ratio is defined as the volume ratio of the gel to the available space in the composite system, and it has been widely studied in the cement unary system. This work determines the gel/space ratio in the cement-silica fume-fly ash ternary system (C-SF-FA system) by measuring the reaction degrees of the cement, SF, and FA. The effects that the supplementary cementitious material (SCM) replacements exert on the evolution of the gel/space ratio are discussed both theoretically and practically. The relationship between the gel/space ratio and compressive strength is then explored, and the relationship disparities for different mix proportions are analyzed in detail. The results demonstrate that the SCM replacements promote the gel/space ratio evolution only when the SCM reaction degree is higher than a certain value, which is calculated and defined as the critical reaction degree (CRD). The effects of the SCM replacements can be predicted based on the CRD, and the theological predictions agree with the test results quite well. At low gel/space ratios, disparities in the relationship between the gel/space ratio and the compressive strength are caused by porosity, which has also been studied in cement unary systems. The ratio of cement-produced gel to SCM-produced gel ( G C to G S C M ratio) is introduced for use in analyzing high gel/space ratios, in which it plays a major role in creating relationship disparities.

  5. Gel/Space Ratio Evolution in Ternary Composite System Consisting of Portland Cement, Silica Fume, and Fly Ash

    Directory of Open Access Journals (Sweden)

    Mengxue Wu

    2017-01-01

    Full Text Available In cement-based pastes, the relationship between the complex phase assemblage and mechanical properties is usually described by the “gel/space ratio” descriptor. The gel/space ratio is defined as the volume ratio of the gel to the available space in the composite system, and it has been widely studied in the cement unary system. This work determines the gel/space ratio in the cement-silica fume-fly ash ternary system (C-SF-FA system by measuring the reaction degrees of the cement, SF, and FA. The effects that the supplementary cementitious material (SCM replacements exert on the evolution of the gel/space ratio are discussed both theoretically and practically. The relationship between the gel/space ratio and compressive strength is then explored, and the relationship disparities for different mix proportions are analyzed in detail. The results demonstrate that the SCM replacements promote the gel/space ratio evolution only when the SCM reaction degree is higher than a certain value, which is calculated and defined as the critical reaction degree (CRD. The effects of the SCM replacements can be predicted based on the CRD, and the theological predictions agree with the test results quite well. At low gel/space ratios, disparities in the relationship between the gel/space ratio and the compressive strength are caused by porosity, which has also been studied in cement unary systems. The ratio of cement-produced gel to SCM-produced gel ( G C to G S C M ratio is introduced for use in analyzing high gel/space ratios, in which it plays a major role in creating relationship disparities.

  6. Innovation of novel 'Tab in Tab' system for release modulation of milnacipran HCl: optimization, formulation and in vitro investigations.

    Science.gov (United States)

    Parejiya, Punit B; Barot, Bhavesh S; Patel, Hetal K; Shelat, Pragna K; Shukla, Arunkumar

    2013-11-01

    The study was aimed toward development of modified release oral drug delivery system for highly water soluble drug, Milnacipran HCl (MH). Novel Tablet in Tablet system (TITs) comprising immediate and extended release dose of MH in different parts was fabricated. The outer shell was composed of admixture of MH, lactose and novel herbal disintegrant obtained from seeds of Lepidium sativum. In the inner core, MH was matrixed with blend of hydrophilic (Benecel®) and hydrophobic (Compritol®) polymers. 3² full factorial design and an artificial neuron network (ANN) were employed for correlating effect of independent variables on dependent variables. The TITs were characterized for pharmacopoeial specifications, in vitro drug release, SEM, drug release kinetics and FTIR study. The release pattern of MH from batch A10 containing 25.17% w/w Benecel® and 8.21% w/w of Compritol® exhibited drug release pattern close proximal to the ideal theoretical profile (t(50%) = 5.92 h, t(75%) = 11.9 h, t(90%) = 18.11 h). The phenomenon of drug release was further explained by concept of percolation and the role of Benecel® and Compritol® in drug release retardation was studied. The normalized error obtained from ANN was less, compared with the multiple regression analysis, and exhibits the higher accuracy in prediction. The results of short-term stability study revealed stable chataracteristics of TITs. SEM study of TITs at different dissolution time points confirmed both diffusion and erosion mechanisms to be operative during drug release from the batch A10. Novel TITs can be a succesful once a day delivery system for highly water soluble drugs.

  7. Thermodynamic analysis of energy conversion and transfer in hybrid system consisting of wind turbine and advanced adiabatic compressed air energy storage

    International Nuclear Information System (INIS)

    Zhang, Yuan; Yang, Ke; Li, Xuemei; Xu, Jianzhong

    2014-01-01

    A simulation model consisting of wind speed, wind turbine and AA-CAES (advanced adiabatic compressed air energy storage) system is developed in this paper, and thermodynamic analysis on energy conversion and transfer in hybrid system is carried out. The impacts of stable wind speed and unstable wind speed on the hybrid system are analyzed and compared from the viewpoint of energy conversion and system efficiency. Besides, energy conversion relationship between wind turbine and AA-CAES system is investigated on the basis of process analysis. The results show that there are several different forms of energy in hybrid system, which have distinct conversion relationship. As to wind turbine, power coefficient determines wind energy utilization efficiency, and in AA-CAES system, it is compressor efficiency that mainly affects energy conversion efficiencies of other components. The strength and fluctuation of wind speed have a direct impact on energy conversion efficiencies of components of hybrid system, and within proper wind speed scope, the maximum of system efficiency could be expected. - Highlights: • A hybrid system consisting of wind, wind turbine and AA-CAES system is established. • Energy conversion in hybrid system with stable and unstable wind speed is analyzed. • Maximum efficiency of hybrid system can be reached within proper wind speed scope. • Thermal energy change in hybrid system is more sensitive to wind speed change. • Compressor efficiency can affect other efficiencies in AA-CAES system

  8. Experimental Physics and Industrial Control System (EPICS): Application source/release control for EPICS R3.11.6

    International Nuclear Information System (INIS)

    Zieman, B.; Kraimer, M.

    1994-01-01

    This manual describes a set of tools that can be used to develop software for EPICS based control systems. It provides the following features: Multiple applications; the entire system is composed of an arbitrary number of applications: Source/Release Control; all files created or modified by the applications developers can be put under sccs (a UNIX Source/Release control utility): Multiple Developers; it allows a number of applications developers to work separately during the development phase but combine their applications for system testing and for a production system; Makefiles: makefiles are provided to automatically rebuild various application components. For C and state notation programs, Imagefiles are provided

  9. Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.

    Science.gov (United States)

    Krajczár, Károly; Varga, Enikő; Marada, Gyula; Jeges, Sára; Tóth, Vilmos

    2016-04-01

    The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the mesiobuccal root canal to the working length, and after preparation with #25, #30 and #40 files. Working lenght changes were detected with measurements between the radiological apex and the instrument tips. In the Mtwo group a difference in the working competency (protary files. Mtwo NiTi rotary file did therefore proved to be more accurate in comparison to the conventional hand instrumentation. Working length, Mtwo, nickel-titanium, hand preparation, engine driven preparation.

  10. Protocol for a multicentre, multistage, prospective study in China using system-based approaches for consistent improvement in surgical safety.

    Science.gov (United States)

    Yu, Xiaochu; Jiang, Jingmei; Liu, Changwei; Shen, Keng; Wang, Zixing; Han, Wei; Liu, Xingrong; Lin, Guole; Zhang, Ye; Zhang, Ying; Ma, Yufen; Bo, Haixin; Zhao, Yupei

    2017-06-15

    Surgical safety has emerged as a crucial global health issue in the past two decades. Although several safety-enhancing tools are available, the pace of large-scale improvement remains slow, especially in developing countries such as China. The present project (Modern Surgery and Anesthesia Safety Management System Construction and Promotion) aims to develop and validate system-based integrated approaches for reducing perioperative deaths and complications using a multicentre, multistage design. The project involves collection of clinical and outcome information for 1 20 000 surgical inpatients at four regionally representative academic/teaching general hospitals in China during three sequential stages: preparation and development, effectiveness validation and improvement of implementation for promotion. These big data will provide the evidence base for the formulation, validation and improvement processes of a system-based stratified safety intervention package covering the entire surgical pathway. Attention will be directed to managing inherent patient risks and regulating medical safety behaviour. Information technology will facilitate data collection and intervention implementation, provide supervision mechanisms and guarantee transfer of key patient safety messages between departments and personnel. Changes in rates of deaths, surgical complications during hospitalisation, length of stay, system adoption and implementation rates will be analysed to evaluate effectiveness and efficiency. This study was approved by the institutional review boards of Peking Union Medical College Hospital, First Hospital of China Medical University, Qinghai Provincial People's Hospital, Xiangya Hospital Central South University and the Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences. Study findings will be disseminated via peer-reviewed journals, conference presentations and patent papers. © Article author(s) (or their employer(s) unless otherwise

  11. A model system for targeted drug release triggered by biomolecular signals logically processed through enzyme logic networks.

    Science.gov (United States)

    Mailloux, Shay; Halámek, Jan; Katz, Evgeny

    2014-03-07

    A new Sense-and-Act system was realized by the integration of a biocomputing system, performing analytical processes, with a signal-responsive electrode. A drug-mimicking release process was triggered by biomolecular signals processed by different logic networks, including three concatenated AND logic gates or a 3-input OR logic gate. Biocatalytically produced NADH, controlled by various combinations of input signals, was used to activate the electrochemical system. A biocatalytic electrode associated with signal-processing "biocomputing" systems was electrically connected to another electrode coated with a polymer film, which was dissolved upon the formation of negative potential releasing entrapped drug-mimicking species, an enzyme-antibody conjugate, operating as a model for targeted immune-delivery and consequent "prodrug" activation. The system offers great versatility for future applications in controlled drug release and personalized medicine.

  12. Production of achromatic spots with a beam transport system consisting only of quadrupoles and/or solenoids

    International Nuclear Information System (INIS)

    Halbach, K.

    1978-01-01

    A description is given of some unfinished work that may have a bearing on the problem of producing a small beam spot on a target for heavy ion fusion. One of the important results obtained so far is an existence proof that shows that it is possible, at least in principle, to design systems, containing only quadrupoles and/or solenoids, with vanishing first and second derivatives of the spotsize with respect to momentum both at the target and at the exit of the last lens

  13. A Novel Degradation Estimation Method for a Hybrid Energy Storage System Consisting of Battery and Double-Layer Capacitor

    Directory of Open Access Journals (Sweden)

    Yuanbin Yu

    2016-01-01

    Full Text Available This paper presents a new method for battery degradation estimation using a power-energy (PE function in a battery/ultracapacitor hybrid energy storage system (HESS, and the integrated optimization which concerns both parameters matching and control for HESS has been done as well. A semiactive topology of HESS with double-layer capacitor (EDLC coupled directly with DC-link is adopted for a hybrid electric city bus (HECB. In the purpose of presenting the quantitative relationship between system parameters and battery serving life, the data during a 37-minute driving cycle has been collected and decomposed into discharging/charging fragments firstly, and then the optimal control strategy which is supposed to maximally use the available EDLC energy is presented to decompose the power between battery and EDLC. Furthermore, based on a battery degradation model, the conversion of power demand by PE function and PE matrix is applied to evaluate the relationship between the available energy stored in HESS and the serving life of battery pack. Therefore, according to the approach which could decouple parameters matching and optimal control of the HESS, the process of battery degradation and its serving life estimation for HESS has been summed up.

  14. The discrete null space method for the energy-consistent integration of constrained mechanical systems. Part III: Flexible multibody dynamics

    International Nuclear Information System (INIS)

    Leyendecker, Sigrid; Betsch, Peter; Steinmann, Paul

    2008-01-01

    In the present work, the unified framework for the computational treatment of rigid bodies and nonlinear beams developed by Betsch and Steinmann (Multibody Syst. Dyn. 8, 367-391, 2002) is extended to the realm of nonlinear shells. In particular, a specific constrained formulation of shells is proposed which leads to the semi-discrete equations of motion characterized by a set of differential-algebraic equations (DAEs). The DAEs provide a uniform description for rigid bodies, semi-discrete beams and shells and, consequently, flexible multibody systems. The constraints may be divided into two classes: (i) internal constraints which are intimately connected with the assumption of rigidity of the bodies, and (ii) external constraints related to the presence of joints in a multibody framework. The present approach thus circumvents the use of rotational variables throughout the whole time discretization, facilitating the design of energy-momentum methods for flexible multibody dynamics. After the discretization has been completed a size-reduction of the discrete system is performed by eliminating the constraint forces. Numerical examples dealing with a spatial slider-crank mechanism and with intersecting shells illustrate the performance of the proposed method

  15. Radiological consequences of radionuclide releases to sewage systems from hospitals in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo; Cruz, Idalmis de la [Facilia AB (Sweden); Bergman, Synnoeve [Vattenfall Power Consultants AB (Sweden); Hasselblad, Serena [Callido AB (Sweden)

    2007-08-15

    The report addresses radioactive discharges to sewers originating from hospitals, mainly in the form of the excretion of patients treated with radioisotopes for diagnostic or therapeutic purposes. Assessments of doses to the public, including sewage workers, arising from such discharges are performed. Doses are compared against the exemption level of 10 {mu}Sv/a and the dose constraint of 100 {mu}Sv/a. As a basis for the dose assessments, information on the use of radionuclides in Swedish hospitals during the period 1999-2004 is presented and estimates of discharges to the sewage systems are derived. Current sewage treatment practices in Sweden are summarised focusing particularly on the fate of sewage sludge, both in the sewage plant and outside. Radiological impact assessments are performed in two steps. The assessments in the first stage are performed using a simple screening model, not intending to predict exposures realistically but only to identify exposure pathways and radionuclides that are potentially relevant and require further consideration in the more detailed assessments. Results show that only a few of those radionuclides used in the period 1999-2004 in Swedish hospitals for radiotherapy and radiodiagnostics could lead to potentially significant doses (P-32, Y-90, Tc-99m, In-111, I-123, I-131 and Tl-201). Relevant exposure pathways are the external exposure of sewage workers (for Tc- 99m, I-123, I-131, In-111 and Tl-201) and the exposure of the public via ingestion of water (I-131) and fish (P-32, Y-90 and In-111 and I-131). The objective of the second stage is to perform realistic assessments of the doses to sewage workers and to the public through the use of contaminated agricultural sludge and through the contamination of drinking water. For this purpose, the LUCIA model was developed. This model dynamically addresses the behaviour of radionuclides in the different process steps of a sewage plant. The model can address continuous releases as well

  16. Analysis and comparison of NoSQL databases with an introduction to consistent references in big data storage systems

    Science.gov (United States)

    Dziedzic, Adam; Mulawka, Jan

    2014-11-01

    NoSQL is a new approach to data storage and manipulation. The aim of this paper is to gain more insight into NoSQL databases, as we are still in the early stages of understanding when to use them and how to use them in an appropriate way. In this submission descriptions of selected NoSQL databases are presented. Each of the databases is analysed with primary focus on its data model, data access, architecture and practical usage in real applications. Furthemore, the NoSQL databases are compared in fields of data references. The relational databases offer foreign keys, whereas NoSQL databases provide us with limited references. An intermediate model between graph theory and relational algebra which can address the problem should be created. Finally, the proposal of a new approach to the problem of inconsistent references in Big Data storage systems is introduced.

  17. Tree species composition in areas of Atlantic Forest in southeastern Brazil is consistent with a new system for classifying the vegetation of South America

    Directory of Open Access Journals (Sweden)

    Pedro Vasconcellos Eisenlohr

    2014-06-01

    Full Text Available Rigorous and well-defined criteria for the classification of vegetation constitute a prerequisite for effective biodiversity conservation strategies. In 2009, a new classification system was proposed for vegetation types in extra-Andean tropical and subtropical South America. The new system expanded upon the criteria established in the existing Brazilian Institute of Geography and Statistics classification system. Here, we attempted to determine whether the tree species composition of the formations within the Atlantic Forest Biome of Brazil is consistent with this new classification system. We compiled floristic surveys of 394 sites in southeastern Brazil (between 15º and 25ºS; and between the Atlantic coast and 55ºW. To assess the floristic consistency of the vegetation types, we performed non-metric multidimensional scaling (NMDS ordination analysis, followed by multifactorial ANOVA. The vegetation types, especially in terms of their thermal regimes, elevational belts and top-tier vegetation categories, were consistently discriminated in the first NMDS axis, and all assessed attributes showed at least one significant difference in the second axis. As was expected on the basis of the theoretical background, we found that tree species composition, in the areas of Atlantic Forest studied, was highly consistent with the new system of classification. Our findings not only help solidify the position of this new classification system but also contribute to expanding the knowledge of the patterns and underlying driving forces of the distribution of vegetation in the region.

  18. Stress and addiction: contribution of the corticotropin releasing factor (CRF system in neuroplasticity

    Directory of Open Access Journals (Sweden)

    Carolina L Haass-Koffler

    2012-09-01

    Full Text Available Corticotropin releasing factor (CRF has been shown to induce various behavioral changes related to adaptation to stress. Dysregulation of the CRF system at any point can lead to a variety of psychiatric disorders, including substance use disorders (SUDs. CRF has been associated with stress-induced drug reinforcement. Extensive literature has identified CRF to play an important role in the molecular mechanisms that lead to an increase in susceptibility that precipitates relapse to SUDs. The CRF system has a heterogeneous role in SUDs. It enhances the acute effects of drugs of abuse and is also responsible for the potentiation of drug-induced neuroplasticity evoked during the withdrawal period. We present in this review the brain regions and circuitries where CRF is expressed and may participate in stress-induced drug abuse. Finally, we attempt to evaluate the role of modulating the CRF system as a possible therapeutic strategy for treating the dysregulation of emotional behaviors that result from the acute positive reinforcement of substances of abuse as well as the negative reinforcement produced by withdrawal.

  19. The impact of ambient dose rate measuring network and precipitation radar system for detection of environmental radioactivity released by accident

    International Nuclear Information System (INIS)

    Bleher, M; Stoehlker, U.

    2003-01-01

    For the surveillance of environmental radioactivity, the German measuring network of BfS consists of more than 2000 stations where the ambient gamma dose rate is continuously measured. This network is a helpful tool to detect and localise enhanced environmental contamination from artificial radionuclides. The threshold for early warning is so low, that already an additional dose rate contribution of 0,07 μGy/h is detectable. However, this threshold is frequently exceeded due to precipitation events caused by washout of natural activity in air. Therefore, the precipitation radar system of the German Weather Service provides valuable information on the problem, whether the increase of the ambient dose rate is due to natural or man-made events. In case of an accidental release, the data of this radar system show small area precipitation events and potential local hot spots not detected by the measuring network. For the phase of cloud passage, the ambient dose rate measuring network provides a reliable database for the evaluation of the current situation and its further development. It is possible to compare measured data for dose rate with derived intervention levels for countermeasures like ''sheltering''. Thus, critical regions can be identified and it is possible to verify implemented countermeasures. During and after this phase of cloud passage the measured data of the monitoring network help to adapt the results of the national decision support systems PARK and RODOS. Therefore, it is necessary to derive the actual additional contribution to the ambient dose rate. Map representations of measured dose rate are rapidly available and helpful to optimise measurement strategies of mobile systems and collection strategies for samples of agricultural products. (orig.)

  20. Consistent pattern of local adaptation during an experimental heat wave in a pipefish-trematode host-parasite system.

    Directory of Open Access Journals (Sweden)

    Susanne H Landis

    Full Text Available Extreme climate events such as heat waves are expected to increase in frequency under global change. As one indirect effect, they can alter magnitude and direction of species interactions, for example those between hosts and parasites. We simulated a summer heat wave to investigate how a changing environment affects the interaction between the broad-nosed pipefish (Syngnathus typhle as a host and its digenean trematode parasite (Cryptocotyle lingua. In a fully reciprocal laboratory infection experiment, pipefish from three different coastal locations were exposed to sympatric and allopatric trematode cercariae. In order to examine whether an extreme climatic event disrupts patterns of locally adapted host-parasite combinations we measured the parasite's transmission success as well as the host's adaptive and innate immune defence under control and heat wave conditions. Independent of temperature, sympatric cercariae were always more successful than allopatric ones, indicating that parasites are locally adapted to their hosts. Hosts suffered from heat stress as suggested by fewer cells of the adaptive immune system (lymphocytes compared to the same groups that were kept at 18°C. However, the proportion of the innate immune cells (monocytes was higher in the 18°C water. Contrary to our expectations, no interaction between host immune defence, parasite infectivity and temperature stress were found, nor did the pattern of local adaptation change due to increased water temperature. Thus, in this host-parasite interaction, the sympatric parasite keeps ahead of the coevolutionary dynamics across sites, even under increasing temperatures as expected under marine global warming.

  1. Cardiovascular safety of the oral controlled absorption system (OCAS) formulation of tamsulosin compared to the modified release (MR) formulation

    NARCIS (Netherlands)

    Michel, M. C.; Korstanje, C.; Klauwinkel, W.; Shear, M.; Davies, J.; Quartel, A.

    2005-01-01

    Objective: The potential to interfere with efferent adrenergic drive in the cardiovascular system was tested in elderly healthy subjects for the new oral controlled absorption system (OCAS) 0.4 mg tablet formulation of tamsulosin compared to the modified release (MR) 0.4 mg capsule formulation of

  2. Development of a magnetic capsule as a drug release system for future applications in the human GI tract

    International Nuclear Information System (INIS)

    Richert, Hendryk; Surzhenko, Oleksy; Wangemann, Sebastian; Heinrich, Jochen; Goernert, Peter

    2005-01-01

    A method for active drug delivery inside the human digestive system is proposed. This method allows the localisation of a magnetically marked capsule on its natural way through the digestive system and to open it at a desired position. Thus, the procedure contains two important components: the magnetic monitoring and active drug release

  3. Plasma methylphenidate concentrations in youths treated with high-dose osmotic release oral system formulation.

    Science.gov (United States)

    Stevens, Jonathan R; George, Robert A; Fusillo, Steven; Stern, Theodore A; Wilens, Timothy E

    2010-02-01

    Children and adolescents are being treated increasingly for attention-deficit/hyperactivity disorder (ADHD) with a variety of stimulants in higher than Food and Drug Administration (FDA)-approved doses and in combination with other medications. We sought to determine methylphenidate (MPH) concentrations in children and adolescents treated with high-dose, extended-release osmotic release oral system (OROS) MPH plus concomitant medications, and to examine MPH concentrations with respect to the safety and tolerability of treatment. Plasma MPH concentrations were measured by liquid chromatography-mass spectrometry 4-5 hours after administration of medication in a sample of youths diagnosed with ADHD. These youths were treated naturalistically with higher than FDA-approved doses of OROS MPH in addition to their concomitant medications. Markers of safety and tolerability (e.g., measures of blood pressure and heart rate) were also examined. Among the 17 patients (with a mean age of 16.2 +/- 2 years and a mean number of concurrent medications of 2.23 +/- 0.94), the mean plasma MPH concentration was 28 +/- 9.1 ng/mL, despite a mean daily dose of OROS MPH of 169 +/- 5 mg (3.0 +/- 0.8 mg/kg per day). No patient had a plasma MPH level >or=50 ng/mL or clinical signs of stimulant toxicity. No correlation was found between plasma MPH concentrations and OROS MPH dose or changes in vital signs. High-dose OROS MPH, used in combination with other medications, was not associated with either unusually elevated plasma MPH concentrations or with clinically meaningful changes in vital signs. Study limitations include a single time-point sampling of MPH concentrations, a small sample size, and a lack of outcome measures to address treatment effectiveness.

  4. Modulation of active pharmaceutical material release from a novel 'tablet in capsule system' containing an effervescent blend.

    Science.gov (United States)

    Gohel, Mukesh C; Sumitra G, Manhapra

    2002-02-19

    The objective of the present study was to obtain programmed drug delivery from hard gelatin capsules containing a hydrophilic plug (HPMC or guar gum). The significance of factors such as type of plug (powder or tablet), plug thickness and the formulation of fill material on the release pattern of diltiazem HCl, a model drug, was investigated. The body portion of the hard gelatin capsules was cross-linked by the combined effect of formaldehyde and heat treatment. A linear relationship was observed between weight of HPMC K15M and log % drug released at 4 h from the capsules containing the plug in powder form. In order to accelerate the drug release after a lag time of 4 h, addition of an effervescent blend, NaHCO(3) and citric acid, in the capsules was found to be essential. The plugs of HPMC in tablet form, with or without a water soluble adjuvant (NaCl or lactose) were used for obtaining immediate drug release after the lag time. Sodium chloride did not cause significant influence on drug release whereas lactose favourably affected the drug release. The capsules containing HPMC K15M tablet plug (200 mg) and 35 mg effervescent blend in body portion of the capsule met the selection criteria of less than 10% drug release in 4 h and immediate drug release thereafter. It is further shown that the drug release was also dependant on the type of swellable hydrophilic agent (HPMC or guar gum) and molecular weight of HPMC (K15M or 20 cPs). The results reveal that programmed drug delivery can be obtained from hard gelatin capsules by systemic formulation approach.

  5. Application of the dose limitation system to the control of carbon-14 releases from heavy-water-moderated reactors

    International Nuclear Information System (INIS)

    Beninson, D.; Gonzalez, A.J.

    1982-01-01

    Heavy-water-moderated reactors produce substantially more carbon-14 than light-water reactors. Applying the principles of the systems of dose limitation, the paper presents the rationale used for establishing the release limit for effluents containing this nuclide and for the decisions made regarding the effluent treatment in the third nuclear power station in Argentina. Production of carbon-14 in PHWR and the release routes are analysed in the light of the different effluent treatment possibilities. An optimization assessment is presented, taking into account effluent treatment and waste management costs, and the collective effective dose commitment due to the releases. The contribution of present carbon-14 releases to future individual doses is also analysed in the light of an upper bound for the contribution, representing a fraction of the individual dose limits. The paper presents the resulting requirements for the effluent treatment regarding carbon-14 and the corresponding regulatory aspects used in Argentina. (author)

  6. Calculation of self-consistent potentials for substitutionally disordered systems with application to the Ag/sub x/-Pd/sub 1-x/ alloy series

    International Nuclear Information System (INIS)

    Winter, H.; Stocks, G.M.

    1983-01-01

    Previous Korringa-Kohn-Rostoker coherent-potential-approximation electronic-structure calculations for substitutionally random alloys have been based on ad hoc potentials. The lack of procedures suitable to provide self-consistent, parameter-free potentials prevented computations for systems consisting of dissimilar atoms and is also the reason why quantities like, for example, cohesive energies or lattice constants, have not so far been evaluated for systems of similar constituents. We present in full detail a generally applicable scheme devised for calculating the self-consistent electronic structures of substitutionally disordered systems. Its feasibility is demonstrated by presenting the results obtained for the Ag/sub x/Pd/sub 1-x/ alloy series. They are compared with those of former non-self-consistent calculations which use Mattheiss prescription potentials and the α = 1 Slater exchange, whereas the von Barth--Hedin expression is employed in our work. The differences are perceptible and have to be understood as combined self-consistency and exchange-correlation effects. .ID BW2039 .PG 905 909

  7. Gastrin-releasing peptide receptors in the central nervous system: role in brain function and as a drug target

    Directory of Open Access Journals (Sweden)

    Rafael eRoesler

    2012-12-01

    Full Text Available Neuropeptides acting on specific cell membrane receptors of the G protein-coupled receptor (GPCR superfamily regulate a range of important aspects of nervous and neuroendocrine function. Gastrin-releasing peptide (GRP is a mammalian neuropeptide that binds to the GRP receptor (GRPR, BB2. Increasing evidence indicates that GRPR-mediated signaling in the central nervous system (CNS plays an important role in regulating brain function, including aspects related to emotional responses, social interaction, memory, and feeding behavior. In addition, some alterations in GRP or GRPR expression or function have been described in patients with neurodegenerative, neurodevelopmental, and psychiatric disorders, as well as in brain tumors. Findings from preclinical models are consistent with the view that the GRPR might play a role in brain disorders, and raise the possibility that GRPR agonists might ameliorate cognitive and social deficits associated with neurological diseases, while antagonists may reduce anxiety and inhibit the growth of some types of brain cancer. Further preclinical and translational studies evaluating the potential therapeutic effects of GRPR ligands are warranted.

  8. Measuring process and knowledge consistency

    DEFF Research Database (Denmark)

    Edwards, Kasper; Jensen, Klaes Ladeby; Haug, Anders

    2007-01-01

    When implementing configuration systems, knowledge about products and processes are documented and replicated in the configuration system. This practice assumes that products are specified consistently i.e. on the same rule base and likewise for processes. However, consistency cannot be taken...... for granted; rather the contrary, and attempting to implement a configuration system may easily ignite a political battle. This is because stakes are high in the sense that the rules and processes chosen may only reflect one part of the practice, ignoring a majority of the employees. To avoid this situation......, this paper presents a methodology for measuring product and process consistency prior to implementing a configuration system. The methodology consists of two parts: 1) measuring knowledge consistency and 2) measuring process consistency. Knowledge consistency is measured by developing a questionnaire...

  9. Scalable Integrated Multi-Mission Support System Simulator Release 3.0

    Science.gov (United States)

    Kim, John; Velamuri, Sarma; Casey, Taylor; Bemann, Travis

    2012-01-01

    The Scalable Integrated Multi-mission Support System (SIMSS) is a tool that performs a variety of test activities related to spacecraft simulations and ground segment checks. SIMSS is a distributed, component-based, plug-and-play client-server system useful for performing real-time monitoring and communications testing. SIMSS runs on one or more workstations and is designed to be user-configurable or to use predefined configurations for routine operations. SIMSS consists of more than 100 modules that can be configured to create, receive, process, and/or transmit data. The SIMSS/GMSEC innovation is intended to provide missions with a low-cost solution for implementing their ground systems, as well as significantly reducing a mission s integration time and risk.

  10. The solution of the Poisson-Boltzmann's equation for self-consistent potential of infinite, random, nonlinear and non-uniform system

    International Nuclear Information System (INIS)

    Rasulova, M.Yu

    1998-01-01

    A study has been made of a system of charged particles and inhomogeneities randomly distributed in accordance with the same law in the neighborhoods of corresponding sites of a planar crystal lattice. The existence and uniqueness of the solution of the generalized Poisson-Boltzmann's equation for the average self-consistent potential and average density of surface charges are proved. (author)

  11. Investigation of chloride-release of nuclear grade resin in PWR primary system coolant

    International Nuclear Information System (INIS)

    Cao Xiaoning; Li Yunde; Li Jinghong; Lin Fangliang

    1997-01-01

    A new preparation technique is developed for making the low-chloride nuclear-grade resin by commercial resin. The chloride remained in nuclear grade resin may release to PWR primary coolant. The amount of released chloride is depended on the concentration of boron, lithium, other anion impurities, and remained chloride concentration in resin

  12. Modified thermoresponsive Poloxamer 407 and chitosan sol-gels as potential sustained-release vaccine delivery systems.

    Science.gov (United States)

    Kojarunchitt, Thunjiradasiree; Baldursdottir, Stefania; Dong, Yao-Da; Boyd, Ben J; Rades, Thomas; Hook, Sarah

    2015-01-01

    Thermoresponsive, particle-loaded, Poloxamer 407 (P407)-Pluronic-R® (25R4) or chitosan-methyl cellulose (MC) formulations were developed as single-dose, sustained release vaccines. The sol-gels, loaded either with a particulate vaccine (cubosomes) or soluble antigen (ovalbumin) and adjuvants (Quil A and monophosphoryl lipid A), were free-flowing liquids at room temperature and formed stable gels at physiological temperatures. Rheological results showed that both systems meet the criteria of being thermoresponsive gels. The P407-25R4 sol-gels did not significantly sustain the release of antigen in vivo while the chitosan-MC sol-gels sustained the release of antigen up to at least 14 days after administration. The chitosan-MC sol-gels stimulated both cellular and humoral responses. The inclusion of cubosomes in the sol-gels did not provide a definitive beneficial effect. Further analysis of the formulations with small-angle X-ray scattering (SAXS) revealed that while cubosomes were stable in chitosan-MC gels they were not stable in P407-25R4 formulations. The reason for the mixed response to cubosome-loaded vehicles requires more investigation, however it appears that the cubosomes did not facilitate synchronous vaccine release and may in fact retard release, reducing efficacy in some cases. From these results, chitosan-MC sol-gels show potential as sustained release vaccine delivery systems, as compared to the P407-25R4 system that had a limited ability to sustain antigen release. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Simulation experiments on the radial pool growth in gas-releasing melting system

    International Nuclear Information System (INIS)

    Farhadieh, R.; Purviance, R.; Carlson, N.

    1983-01-01

    Following an HCDA, molten core-debris can contact the concrete foundation of the reactor building resulting in a molten UO 2 /concrete interaction and considerable gas release. The released gas can pressurize the containment building potentially leading to radiological releases. Furthermore, directional growth of the molten core-debris pool can reduce the reactor building structural integrity. To implement design changes that insure structural integrity, an understanding of the thermal-hydraulic and mass-transfer process associated with such a growth is most desirable. Owing to the complex nature of the combined heat, mass, and hydrodynamic processes associated with the two-dimensional problem of gas release and melting, the downward and radial penetration problems have been investigated separately. The present experimental study addresses the question of sideward penetration of the molten core debris into a gas-releasing, meltable, miscible solid

  14. Long term safety assessment of geological waste disposal systems: issues on release scenarios

    International Nuclear Information System (INIS)

    Khan, S.A.; Qureshi, A.A.

    1995-01-01

    Geological insolation of high level nuclear waste is an attractive waste disposal concept. However, long term safety demonstration of this concept is a major challenge to the operators, regulators and the scientific community. Identification of the factors responsible for the release of radionuclides from geosphere to biosphere,is first step in this regard. Current understanding of the release scenarios indicates that faulting, ground after percolation, seismicity, volcanism and human intrusion are the dominating release factors for most of the candidate rock formations. The major source of uncertainties is the probability values of various release events due to random nature of catastrophic geological events and past poor historical records of the frequencies of such events. There is consensus among the experts that the waste release via human intrusion is the most unpredictable scenario at present state of the knowledge. (author)

  15. Validation of a numerical release model (REPCOM) for the Finnish reactor waste disposal systems: Pt.1

    International Nuclear Information System (INIS)

    Nykyri, Mikko

    1987-05-01

    The aim of the work is to model experimentally the inner structures and materials of two reactor waste repositories and to use the results for the validation work of a numerical near field release model, REPCOM. The experimental modelling of the multibarrier systems is conducted on a laboratory scale by using the same principal materials as are employed in the Finnish reactor waste disposal concepts. The migration of radionuclides is studied in two or more consecutive material layers. The laboratory arrangements include the following test materials: bituminized resin, cemented resin, concrete, crushed rock, and water. The materials correspond to the local materials in the planned disposal systems. Cs-137, Co-60, Sr-85, and Sr-90 are used as tracers, with which the resin, water, and crushed rock are labeled depending on the specimen type. The basic specimen geometries are cylindrical and cubic. In the cylindrical geometry the test materials were placed into PVC-tubes. The corresponding numerical model is one-dimensional. In the cubic geometry the materials were placed inside each other. The boundaries form cubes, and the numerical model is three-dimensional. Altogether 12 test system types were produced. The gamma active nuclides in the cylindrical samples were measured nondestructively with a scanner in order to determine the activity profiles in the specimens. The gamma active nuclides in the cubic samples and the beta emeitting Sr-90 in separate samples will be measured after splitting the samples. One to five activity profiles were determined for each cylindrical gamma-active sample. There are already clear diffusion profiles to be had for strontium in crushed rock, and for cesium in crushed rock and in concrete. Cobalt indicated no diffusion. No activity profiles were measured for the cubic samples or for the beta active, Sr-90-doped samples

  16. Sensitivity of the engineered barrier system (EBS) release rate to alternative conceptual models of advective release from waste packages under dripping fractures

    International Nuclear Information System (INIS)

    Lee, J.H.; Atkins, J.E.; McNeish, J.A.; Vallikat, V.

    1996-01-01

    The first model assumed that dripping water directly contacts the waste form inside the ''failed'' waste package and radionuclides are released from the EBS by advection. The second model assumed that dripping water is diverted around the package (because of corrosion products plugging the perforations), thereby being prevented from directly contacting the waste form. In the second model, radionuclides were assumed to diffuse through the perforations, and, once outside the waste package, to be released from the EBS by advection. For the case with the second EBS release model, most radionuclides had lower peak EBS release rates than with the first model. Impacts of the alternative EBS release models were greater for the radionuclides with low solubility. The analysis indicated that the EBS release model representing advection through a ''failed'' waste package (the first model) may be too conservative; thus a ''failed'' waste package container with multiple perforations may still be an important barrier to radionuclide release

  17. Benchtop-magnetic resonance imaging (BT-MRI) characterization of push-pull osmotic controlled release systems.

    Science.gov (United States)

    Malaterre, Vincent; Metz, Hendrik; Ogorka, Joerg; Gurny, Robert; Loggia, Nicoletta; Mäder, Karsten

    2009-01-05

    The mechanism of drug release from push-pull osmotic systems (PPOS) has been investigated by Magnetic Resonance Imaging (MRI) using a new benchtop apparatus. The signal intensity profiles of both PPOS layers were monitored non-invasively over time to characterize the hydration and swelling kinetics. The drug release performance was well-correlated to the hydration kinetics. The results show that (i) hydration and swelling critically depend on the tablet core composition, (ii) high osmotic pressure developed by the push layer may lead to bypassing the drug layer and incomplete drug release and (iii) the hydration of both the drug and the push layers needs to be properly balanced to efficiently deliver the drug. MRI is therefore a powerful tool to get insights on the drug delivery mechanism of push-pull osmotic systems, which enable a more efficient optimization of such formulations.

  18. Release of WIMS10: a versatile reactor physics code for thermal and fast systems - 15467

    International Nuclear Information System (INIS)

    Lindley, B.A.; Newton, T.D.; Hosking, J.G.; Smith, P.N.; Powney, D.J.; Tollit, B.; Smith, P.J.

    2015-01-01

    the WIMS code provides a versatile software package for neutronic calculations, which can be applied to all thermal reactor types including mixed moderator systems. It can provide lattice cell and supercell calculations using a range of flux solutions methods to produce the neutronic libraries for use in PANTHER or other whole core analysis codes. With the release of WIMS10, the range of problems which WIMS can solve has been greatly extended. A WIMS/PANTHER calculation route has been developed and validated for part MOX-fuelled PWRs, with calculations showing excellent agreement with 2D core deterministic and Monte Carlo transport solutions. A flexible geometry 3D method of characteristics transport solver, CACTUS3D has been added to the code. CACTUS3D has been benchmarked for a 3D BWR assembly model, and was in good agreement with a direct 172-group solution in the Monte Carlo code MONK. Fast reactor calculations using the ECCO deterministic calculation route have been validated using experimental data from the ZEBRA reactor. Power deposition can be treated through following neutrons and/or photons to their point of interaction. The improved methodology is shown to give more accurate calculation of heat deposition and improve agreement between calculated and measured detector responses for part MOX-fuelled cores. (authors)

  19. A sustained release system using porous cellulose spheres modified by grafting as matrices

    International Nuclear Information System (INIS)

    Hosoi, Fumio; Makuuchi, Keizo; Saito, Kenji; Koishi, Masumi.

    1987-01-01

    Polymer-coated spheres, obtained by the graft polymerization of methyl methacrylate (MMA) onto porous spheres based on cellulose by the pre-irradiation method, were used as matrices for the drug sustained release system for salicylic acid. The adsorption of salicylic acid was carried out by dipping the grafted spheres in a 50% aqueous ethanol solution containing salicylic acid. The amount of salicylic acid adsorbed (Q) increased proportionately with the percent graft of MMA (G) to the power of 2.9. Adsorption mechanism of salicylic acid could be expressed in term of Langmuir's adsorption isotherm. The ratio of constants for adsorption and desorption (k) and the saturated amount of salicylic acid adsorbed (Q 0 ) were expressed as k = k 1 G and Q 0 = k 2 G 2.4 , respectively. These results indicate that the number of adsorption sites increased proportionately with the nth power of G as a results of the interaction of grafted poly (methyl methacrylate)(PMMA) and cellulose. Similar results were obtained with grafting of MMA, MMA-styrene (St), and MMA-methacrylic acid (MAc) in the presence of salicylic acid. (author)

  20. Autoradiographic localization of thyrotropin releasing hormone (TRH) receptors in the central nervous system

    International Nuclear Information System (INIS)

    Manaker, S.

    1985-01-01

    Quantitative autoradiography was used to examine the distribution of thyrotropin-releasing hormone (TRH) receptors in the rat and human central nervous system (CNS). The binding of [ 3 H]-3-methyl-histidine 2 -TRH ([ 3 H]-MeTRH) to TRH receptors was saturable, of a high affinity (K/sub d/ = 5 nM), and specific for TRH analogs. Studies with neurotoxins ibotenic acid and 6-hydroxydopamine (6-OHDA) suggest that TRH receptors within the amygdala are predominantly located on cell bodies, and not nerve terminals. Finally, an examination was made of the concentrations of TRH receptors in spinal cords of patients with amyotrophic lateral sclerosis (ALS), a degenerative disease of the motor neurons located in Lamina IX. Large decreases in TRH receptors were noted in ALS spinal cords, when compared to non-neurological controls, probably reflecting the loss of motor neurons. In addition, decreases in the TRH receptor concentration of Lamina II were observed. This finding may reflect the sensitivity of neurons throughout the CNS to the pathophysiologic mechanisms of neuronal degeneration which cause ALS

  1. Novel Polyurethane Matrix Systems Reveal a Particular Sustained Release Behavior Studied by Imaging and Computational Modeling.

    Science.gov (United States)

    Campiñez, María Dolores; Caraballo, Isidoro; Puchkov, Maxim; Kuentz, Martin

    2017-07-01

    The aim of the present work was to better understand the drug-release mechanism from sustained release matrices prepared with two new polyurethanes, using a novel in silico formulation tool based on 3-dimensional cellular automata. For this purpose, two polymers and theophylline as model drug were used to prepare binary matrix tablets. Each formulation was simulated in silico, and its release behavior was compared to the experimental drug release profiles. Furthermore, the polymer distributions in the tablets were imaged by scanning electron microscopy (SEM) and the changes produced by the tortuosity were quantified and verified using experimental data. The obtained results showed that the polymers exhibited a surprisingly high ability for controlling drug release at low excipient concentrations (only 10% w/w of excipient controlled the release of drug during almost 8 h). The mesoscopic in silico model helped to reveal how the novel biopolymers were controlling drug release. The mechanism was found to be a special geometrical arrangement of the excipient particles, creating an almost continuous barrier surrounding the drug in a very effective way, comparable to lipid or waxy excipients but with the advantages of a much higher compactability, stability, and absence of excipient polymorphism.

  2. Control of drug releasing from biodegradable polymer drug delivery system by gamma-ray irradiation

    International Nuclear Information System (INIS)

    Yoshioka, Sumie; Aso, Yukio; Kojima, Shigeo

    1999-01-01

    In order to introduce the drug to the target organ, we developed a gel to control the drug releasing velocity by response to change of temperature by means of γ-ray irradiation to gelatin-GMA modified dextran mixture aqueous solution. A certain level of molecular weight of drug is necessary. The response to the temperature (change of drug releasing velocity) was affected by the concentration of gelatin and the modification rate of GMA. The Higuchi equation was applied to the releasing of β-galactosidase from gelatin-dextran gel and the releasing velocity was calculated. The releasing velocity decreased with increasing GMA modification rate at 37degC and 15degC. The releasing velocity of β-galactosidase decreased with increasing the concentration of gelatin at 15degC, but the velocity increased with increasing the concentration at 37degC. These results indicated that the good drug releasing conditions are obtained by controlling the GMA modification rate and the concentration of gelatin. (S.Y.)

  3. Sterile insect supply, emergence, and release

    International Nuclear Information System (INIS)

    Dowell, R.V.; Worley, J.; Gomes, P.J.

    2005-01-01

    Insect mass-rearing for a sterile insect technique (SIT) programme is designed to move beyond the large-scale rearing of insects in a laboratory to the industrial production of consistently high-quality insects for sterilization and release. Each facility reflects the unique biology of the insect reared within it, but there are some generalities for all rearing facilities. Rearing insects in self-contained modules offers flexibility, and increased safety from catastrophic occurrences, compared with using a single building which houses all facets of the rearing process. Although mechanizing certain aspects of the rearing steps helps provide a consistently high-quality insect, successful mass-rearing and delivery depends largely upon the human component. Besides production in centralized facilities, insects can be produced from purchased eggs, or nowadays, adult insects are often obtained from specialized satellite emergence/collection facilities. Interest in commercializing insect production and release is increasing. Shipping sterile insects, sometimes over long distances, is now common practice. Procedures for handling and chilling adult insects, and providing food and water prior to release, are continually being improved. Sterile insects are released via static-release receptacles, ground-release systems, or most commonly from the air. The aerial release of chilled sterile insects is the most efficient method of release, especially when aircraft flight paths are guided by a Global Positioning System (GPS) linked to a computer-controlled release mechanism. (author)

  4. Ingenious pH-sensitive dextran/mesoporous silica nanoparticles based drug delivery systems for controlled intracellular drug release.

    Science.gov (United States)

    Zhang, Min; Liu, Jia; Kuang, Ying; Li, Qilin; Zheng, Di-Wei; Song, Qiongfang; Chen, Hui; Chen, Xueqin; Xu, Yanglin; Li, Cao; Jiang, Bingbing

    2017-05-01

    In this work, dextran, a polysaccharide with excellent biocompatibility, is applied as the "gatekeeper" to fabricate the pH-sensitive dextran/mesoporous silica nanoparticles (MSNs) based drug delivery systems for controlled intracellular drug release. Dextran encapsulating on the surface of MSNs is oxidized by NaIO 4 to obtain three kinds of dextran dialdehydes (PADs), which are then coupled with MSNs via pH-sensitive hydrazone bond to fabricate three kinds of drug carriers. At pH 7.4, PADs block the pores to prevent premature release of anti-cancer drug doxorubicin hydrochloride (DOX). However, in the weakly acidic intracellular environment (pH∼5.5) the hydrazone can be ruptured; and the drug can be released from the carriers. The drug loading capacity, entrapment efficiency and release rates of the drug carriers can be adjusted by the amount of NaIO 4 applied in the oxidation reaction. And from which DOX@MSN-NH-N=C-PAD 10 is chosen as the most satisfactory one for the further in vitro cytotoxicity studies and cellular uptake studies. The results demonstrate that DOX@MSN-NH-N=C-PAD 10 with an excellent pH-sensitivity can enter HeLa cells to release DOX intracellular due to the weakly acidic pH intracellular and kill the cells. In our opinion, the ingenious pH-sensitive drug delivery systems have application potentials for cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Conceptual Design of Portable Filtered Air Suction Systems For Prevention of Released Radioactive Gas under Severe Accidents of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Beom W.; Choi, Su Y.; Yim, Man S.; Rim, Chun T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    It becomes evident that severe accidents may occur by unexpected disasters such as tsunami, heavy flood, or terror. Once radioactive material is released from NPP through severe accidents, there are no ways to prevent the released radioactive gas spreading in the air. As a remedy for this problem, the idea on the portable filtered air suction system (PoFASS) for the prevention of released radioactive gas under severe accidents was proposed. In this paper, the conceptual design of a PoFASS focusing on the number of robot fingers and robot arm rods are proposed. In order to design a flexible robot suction nozzle, mathematical models for the gaps which represent the lifted heights of extensible covers for given convex shapes of pipes and for the covered areas are developed. In addition, the system requirements for the design of the robot arms of PoFASS are proposed, which determine the accessible range of leakage points of released radioactive gas. In this paper, the conceptual designs of the flexible robot suction nozzle and robot arm have been conducted. As a result, the minimum number of robot fingers and robot arm rods are defined to be four and three, respectively. For further works, extensible cover designs on the flexible robot suction nozzle and the application of the PoFASS to the inside of NPP should be studied because the radioactive gas may be released from connection pipes between the containment building and auxiliary buildings.

  6. Model-Data Fusion and Adaptive Sensing for Large Scale Systems: Applications to Atmospheric Release Incidents

    Science.gov (United States)

    Madankan, Reza

    All across the world, toxic material clouds are emitted from sources, such as industrial plants, vehicular traffic, and volcanic eruptions can contain chemical, biological or radiological material. With the growing fear of natural, accidental or deliberate release of toxic agents, there is tremendous interest in precise source characterization and generating accurate hazard maps of toxic material dispersion for appropriate disaster management. In this dissertation, an end-to-end framework has been developed for probabilistic source characterization and forecasting of atmospheric release incidents. The proposed methodology consists of three major components which are combined together to perform the task of source characterization and forecasting. These components include Uncertainty Quantification, Optimal Information Collection, and Data Assimilation. Precise approximation of prior statistics is crucial to ensure performance of the source characterization process. In this work, an efficient quadrature based method has been utilized for quantification of uncertainty in plume dispersion models that are subject to uncertain source parameters. In addition, a fast and accurate approach is utilized for the approximation of probabilistic hazard maps, based on combination of polynomial chaos theory and the method of quadrature points. Besides precise quantification of uncertainty, having useful measurement data is also highly important to warranty accurate source parameter estimation. The performance of source characterization is highly affected by applied sensor orientation for data observation. Hence, a general framework has been developed for the optimal allocation of data observation sensors, to improve performance of the source characterization process. The key goal of this framework is to optimally locate a set of mobile sensors such that measurement of textit{better} data is guaranteed. This is achieved by maximizing the mutual information between model predictions

  7. Effect of co-administration of probiotics with polysaccharide based colon targeted delivery systems to optimize site specific drug release.

    Science.gov (United States)

    Prudhviraj, G; Vaidya, Yogyata; Singh, Sachin Kumar; Yadav, Ankit Kumar; Kaur, Puneet; Gulati, Monica; Gowthamarajan, K

    2015-11-01

    Significant clinical success of colon targeted dosage forms has been limited by their inappropriate release profile at the target site. Their failure to release the drug completely in the colon may be attributed to changes in the colonic milieu because of pathological state, drug effect and psychological stress accompanying the diseased state or, a combination of these. Alteration in normal colonic pH and bacterial picture leads to incomplete release of drug from the designed delivery system. We report the effectiveness of a targeted delivery system wherein the constant replenishment of the colonic microbiota is achieved by concomitant administration of probiotics along with the polysaccharide based drug delivery system. Guar gum coated spheroids of sulfasalazine were prepared. In the dissolution studies, these spheroids showed markedly higher release in the simulated colonic fluid. In vivo experiments conducted in rats clearly demonstrated the therapeutic advantage of co-administration of probiotics with guar gum coated spheroids. Our results suggest that concomitant use of probiotics along with the polysaccharide based delivery systems can be a simple strategy to achieve satisfactory colon targeting of drugs. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Comparison of vascular alpha(1)-adrenoceptor antagonism of tamsulosin in oral controlled absorption system (OCAS) and modified release (MR) formulations

    NARCIS (Netherlands)

    Michel, M. C.; Korstanje, C.; Krauwinkel, W.; Shear, M.; Davies, J.; Quartel, A.

    2005-01-01

    Objective: The cardiovascular a-l-adrenoceptor (AR) antagonism of the new oral controlled absorption system (OCAS) 0.4 mg tablet formulation of tamsulosin was compared with that of the modified release (MR) 0.4 mg capsule formulation in healthy male volunteers after a single dose in the fasted

  9. Comparison of the cardiovascular effects of tamsulosin oral controlled absorption system (OCAS) and alfuzosin prolonged release (XL)

    NARCIS (Netherlands)

    Michel, Martin C.; Chapple, Christopher R.

    2006-01-01

    OBJECTIVE: The cardiovascular (CV) effects of tamsulosin oral controlled absorption system (OCAS) 0.4 mg were compared with those of alfuzosin prolonged release (XL) 10 mg. METHODS: Two single-dose, crossover studies were performed. In study 1, CV alpha1-adrenoceptor antagonism was assessed by

  10. Form and toxicity of copper released into marine systems from conventionally and nano-sized copper treated lumber

    Science.gov (United States)

    The fate and effects of pristine engineered nanomaterials (ENMs) in simplified systems have been widely studied; however, little is known about the potential release and impact of ENMs from consumer goods, especially lumber that has been treated with micronized copper. Micronized...

  11. Factors influencing release of phosphorus from sediments in a high productive polymictic lake system.

    Science.gov (United States)

    Solim, S U; Wanganeo, A

    2009-01-01

    Phosphorus (P) release rates from bottom sediments are high (20.6 mg/m(2)/day) in Dal Lake (India), a polymictic hyper-eutrophic lake. These gross release rates occur over a period of 72 days during summer only. Likewise, a net internal load of 11.3 tons was obtained from mass balance estimates. Significant proportion i.e. approximately 80% of 287.3 tons/yr of nitrate nitrogen (NO(3)-N) load is either eliminated by denitrification or gets entrapped for a short period in high macrophyte biomass of 3.2 kg/m(2) f.w., which eventually get decomposed and nitrogen (N) is released back. These processes result in low lake water NO(3)-N concentrations which potentially influence sediment phosphorus (P) release. Especially, nitrate nitrogen (NO(3)-N) 500 microg/L in the lake waters were associated with high P concentrations. Phosphorus was also observed to increase significantly in relation to temperature and pH, and it seems likely that release of phosphorus and ammonical nitrogen (NH(4)-N) depend on decomposition of rich reserves of organic matter (893 tons d.w. in superficial 10-cm bottom sediment layer). Lake P concentrations were significantly predicted by a multivariate regression model developed for the lake. This study describes significance of various lake water variables in relation to P-release from bottom sediments.

  12. RELOS.MOD2: a code system for the determination of instationary fission product releases from molten pools

    International Nuclear Information System (INIS)

    Kortz, Ch.; Koch, M.K.; Unger, H.; Funke, F.

    1999-01-01

    For the assessment of molten corium pool source terms, a mechanistic model has been developed to describe the transport of fission products from liquid corium pool surfaces into a colder gas atmosphere. Modelling is based on an approach for diffusive and convective transport processes coupled with thermochemical equilibrium considerations enabling detailed speciation analyses of the fission products released. Both have been implemented into the code system RELOS.MOD2. RELOS.MOD2 sensitivity calculations on possible effects of anticipated uncertainties in the thermo-chemical data on the fission product release predictions are presented. (author)

  13. Construction and evaluation of controlled-release delivery system of Abamectin using porous silica nanoparticles as carriers.

    Science.gov (United States)

    Wang, Yan; Cui, Haixin; Sun, Changjiao; Zhao, Xiang; Cui, Bo

    2014-12-01

    Photolysis and poor solubility in water of Abamectin are key issues to be addressed, which causes low bioavailability and residual pollution. In this study, a novel hydrophilic delivery system through loading Abamectin with porous silica nanoparticles (Abam-PSNs) was developed in order to improve the chemical stability, dispersity, and the controlled release of Abamectin. These results suggest that Abam-PSNs can significantly improve the performance of controllable release, photostability, and water solubility of Abamectin by changing the porous structure of silica nanoparticles, which is favorable to improve the bioavailability and reduce the residues of pesticides.

  14. The Consistent Support System in The Society for Lifelong Sports : From a View Point of Self-Organization of Sports Club and Support

    OpenAIRE

    長岡, 雅美; 赤松, 喜久; Masami, Nagaoka; Yoshihisa, Akamatsu

    2008-01-01

    The purpose of this study is to clarify the concept of Guidance and Support on community sports and to specify the directionality of organization and support for achievement of the sports society through life. The authors have stressed that it is necessary for achievement of the society for longlife sports,to cooperate with other groups and to construct a consistent support system. This study is also to explore the condition of community sports club management through analyzing the Japan Juni...

  15. The effect of solvents and hydrophilic additive on stable coating and controllable sirolimus release system for drug-eluting stent.

    Science.gov (United States)

    Kim, Seong Min; Park, Sung-Bin; Bedair, Tarek M; Kim, Man-Ho; Park, Bang Ju; Joung, Yoon Ki; Han, Dong Keun

    2017-09-01

    Various drug-eluting stents (DESs) have been developed to prevent restenosis after stent implantation. However, DES still needs to improve the drug-in-polymer coating stability and control of drug release for effective clinical treatment. In this study, the cobalt-chromium (CoCr) alloy surface was coated with biodegradable poly(D,L-lactide) (PDLLA) and sirolimus (SRL) mixed with hydrophilic Pluronic F127 additive by using ultrasonic spray coating system in order to achieve a stable coating surface and control SRL release. The degradation of PDLLA/SRL coating was studied under physiological solution. It was found that adding F127 reduced the degradation of PDLLA and improved the coating stability during 60days. The effects of organic solvent such as chloroform and tetrahydrofuran (THF) on the coating uniformity were also examined. It was revealed that THF produced a very smooth and uniform coating compared to chloroform. The patterns of in vitro drug release according to the type of organic solvent and hydrophilic additive proposed the possibility of controllable drug release design in DES. It was found that using F127 the drug release was sustained regardless of the organic solvent used. In addition, THF was able to get faster and controlled release profile when compared to chloroform. The structure of SRL molecules in different organic solvents was investigated using ultra-small angle neutron scattering. Furthermore, the structure of SRL is concentration-dependent in chloroform with tight nature under high concentration, but concentration-independent in THF. These results strongly demonstrated that coating stability and drug release patterns can be changed by physicochemical properties of various parameters such as organic solvents, additive, and coating strategy. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Deployable Plume and Aerosol Release Prediction and Tracking System. Nuclear Non-Proliferation Task 1. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Kleppe, John; Norris, William; Etezadi, Mehdi

    2006-07-19

    This contract was awarded in response to a proposal in which a deployable plume and aerosol release prediction and tracking system would be designed, fabricated, and tested. The system would gather real time atmospheric data and input it into a real time atmospheric model that could be used for plume predition and tracking. The system would be able to be quickly deployed by aircraft to points of interest or positioned for deployment by vehicles. The system would provide three dimensional (u, v, and w) wind vector data, inversion height measurements, surface wind information, classical weather station data, and solar radiation. The on-board real time computer model would provide the prediction of the behavior of plumes and released aerosols.

  17. RPP-PRT-58489, Revision 1, One Systems Consistent Safety Analysis Methodologies Report. 24590-WTP-RPT-MGT-15-014

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Mukesh [URS Professional Solutions LLC, Aiken, SC (United States); Niemi, Belinda [Washington River Protection Solutions, LLC, Richland, WA (United States); Paik, Ingle [Washington River Protection Solutions, LLC, Richland, WA (United States)

    2015-09-02

    In 2012, One System Nuclear Safety performed a comparison of the safety bases for the Tank Farms Operations Contractor (TOC) and Hanford Tank Waste Treatment and Immobilization Plant (WTP) (RPP-RPT-53222 / 24590-WTP-RPT-MGT-12-018, “One System Report of Comparative Evaluation of Safety Bases for Hanford Waste Treatment and Immobilization Plant Project and Tank Operations Contract”), and identified 25 recommendations that required further evaluation for consensus disposition. This report documents ten NSSC approved consistent methodologies and guides and the results of the additional evaluation process using a new set of evaluation criteria developed for the evaluation of the new methodologies.

  18. Systemic Administration of Carbon Monoxide-Releasing Molecule-3 Protects the Skeletal Muscle in Porcine Model of Compartment Syndrome.

    Science.gov (United States)

    Bihari, Aurelia; Cepinskas, Gediminas; Sanders, David; Lawendy, Abdel-Rahman

    2018-05-01

    Acute limb compartment syndrome, a complication of musculoskeletal trauma, results in muscle necrosis and cell death. Carbon monoxide, liberated from the carbon monoxide-releasing molecule-3, has been shown protective in a rat model of compartment syndrome. The purpose of this study was to test the effect of carbon monoxide-releasing molecule-3 in a preclinical large animal model of compartment syndrome, with the ultimate goal of developing a pharmacologic adjunct treatment for compartment syndrome. Animal research study. Basic research laboratory in a hospital setting. Male Yorkshire-Landrace pigs (50-60 kg). Pigs underwent 6 hours of intracompartmental pressure elevation by infusing fluid into the anterior compartment of the right hind limb. Carbon monoxide-releasing molecule-3 was administered systemically (2 mg/kg, IV) at fasciotomy, followed by 3-hour reperfusion. Muscle perfusion, inflammation, injury, and apoptosis were assessed in the skeletal muscle. Systemic leukocyte activation was assessed during compartment syndrome and reperfusion. Elevation of hind limb intracompartmental pressure resulted in significant microvascular perfusion deficits (44% ± 1% continuously perfused capillaries in compartment syndrome vs 76% ± 4% in sham; p molecule-3 at fasciotomy increased the number of continuously perfused capillaries (68% ± 3%; p molecule-3 at fasciotomy offered protection against compartment syndrome-induced microvascular perfusion deficit, tissue injury, and systemic leukocyte activation. The data suggest the potential therapeutic application of carbon monoxide-releasing molecule-3 to patients at risk of developing compartment syndrome.

  19. Effect of Guizhifuling capsule combined with levonorgestrel releasing intrauterine system on adenomyosis

    Directory of Open Access Journals (Sweden)

    Dong-Tao Shi

    2016-11-01

    Full Text Available Objective: To explore the clinical efficacy of Guizhifuling capsule combined with levonorgestrel releasing intrauterine system (LNG-IUS in the treatment of adenomyosis (AM. Methods: A total of 80 patients with AM who were admitted in our hospital from February, 2015 to February, 2016 were included in the study and randomized into the study group and the control group. LNG-IUS was placed in patients in the two groups 7 d after menstruation. The patients in the study group were given additional Guizhifuling capsule, 3 capsules/time, 3 times/d, and the drug was withdrawn in the menstrual period. Six-month treatment was regarded as one course. PBAC was used to evaluate the menstrual blood volume before and after treatment. The chronic pain grading questionnaire method was used for dysmenorrhea degree rating. The vaginal B ultrasound 3 d after menstruation was performed to detect the uterine volume. E2, FSH, LH, and serum CA125 level before and after treatment were detected. Results: The menstrual blood volume, dysmenorrhea degree, and uterine volume after treatment in the two groups were significantly reduced when compared with before treatment (P0.05. After treatment, CA125 level in the two groups was significantly reduced when compared with before treatment (P<0.05, and the reduced degree in the study group was significantly superior to that in the control group (P<0.05. Conclusions: Guizhifuling capsule combined with LNG-IUS in the treatment of AM can significantly improve the clinical symptoms, effectively reduce CA125 level, and has no significant effect on the sex hormone levels with a satisfactory clinical efficacy; therefore, it deserves to be widely recommended in the clinic.

  20. Two step novel hydrogen system using additives to enhance hydrogen release from the hydrolysis of alane and activated aluminum

    Science.gov (United States)

    Zidan, Ragaiy; Teprovich, Joseph A.; Motyka, Theodore

    2015-12-01

    A system for the generation of hydrogen for use in portable power systems is set forth utilizing a two-step process that involves the thermal decomposition of AlH.sub.3 (10 wt % H.sub.2) followed by the hydrolysis of the activated aluminum (Al*) byproduct to release additional H.sub.2. Additionally, a process in which water is added directly without prior history to the AlH.sub.3:PA composite is also disclosed.

  1. Biodegradable polyesters for veterinary drug delivery systems: Characterization, in vitro degradation and release behavior of Oligolactides and Polytartrate

    OpenAIRE

    Schliecker, Gesine

    2004-01-01

    This thesis deals with the degradation and release behavior of aliphatic polyesters with special respect to the influence of oligomers on the degradation rate and the potential use of these biomaterials for the development of veterinary drug delivery systems. In Chapter 1 the animal health care market is introduced with regard to opportunities and challenges of veterinary drug delivery systems. . In the second part of this chapter...

  2. A novel oral delivery system consisting in "drug-in cyclodextrin-in nanostructured lipid carriers" for poorly water-soluble drug: vinpocetine.

    Science.gov (United States)

    Lin, Congcong; Chen, Fen; Ye, Tiantian; Zhang, Lina; Zhang, Wenji; Liu, Dandan; Xiong, Wei; Yang, Xinggang; Pan, Weisan

    2014-04-25

    The purpose of this study was to develop a new delivery system based on drug cyclodextrin (CD) complexation and loading into nanostructured lipid carriers (NLC) to improve the oral bioavailability of vinpocetine (VP). Three different CDs and three different methods to obtain solid vinpocetine-cyclodextrin-tartaric acid complexes (VP-CD-TA) were contrasted. The co-evaporation vinpocetine-β-cyclodextrin-tartaric acid loaded NLC (VP-β-CD-TA COE-loaded NLC) was obtained by emulsification ultrasonic dispersion method. VP-β-CD-TA COE-loaded NLC was suitably characterized for particle size, polydispersity index, zeta potential, entrapment efficiency and the morphology. The crystallization of drug in VP-CD-TA and NLC was investigated by differential scanning calorimetry (DSC). The in vitro release study was carried out at pH 1.2, pH 6.8 and pH 7.4 medium. New Zealand rabbits were applied to investigate the pharmacokinetic behavior in vivo. The VP-β-CD-TA COE-loaded NLC presented a superior physicochemical property and selected to further study. In the in vitro release study, VP-β-CD-TA COE-loaded NLC exhibited a higher dissolution rate in the pH 6.8 and pH 7.4 medium than VP suspension and VP-NLC. The relative bioavailability of VP-β-CD-TA COE-loaded NLC was 592% compared with VP suspension and 92% higher than VP-NLC. In conclusion, the new formulation significantly improved bioavailability of VP for oral delivery, demonstrated a perspective way for oral delivery of poorly water-soluble drugs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Compact microelectrode array system: tool for in situ monitoring of drug effects on neurotransmitter release from neural cells.

    Science.gov (United States)

    Chen, Yu; Guo, Chunxian; Lim, Layhar; Cheong, Serchoong; Zhang, Qingxin; Tang, Kumcheong; Reboud, Julien

    2008-02-15

    This paper presents a compact microelectrode array (MEA) system, to study potassium ion-induced dopamine release from PC12 neural cells, without relying on a micromanipulator and a microscope. The MEA chip was integrated with a custom-made "test jig", which provides a robust electrical interfacing tool between the microchip and the macroenvironment, together with a potentiostat and a microfluidic syringe pump. This integrated system significantly simplifies the operation procedures, enhances sensing performance, and reduces fabrication costs. The achieved detection limit for dopamine is 3.8 x 10-2 muM (signal/noise, S/N = 3) and the dopamine linear calibration range is up to 7.39 +/- 0.06 muM (mean +/- SE). The effects of the extracelluar matrix collagen coating of the microelectrodes on dopamine sensing behaviors, as well as the influences of K+ and l-3,4-digydroxyphenylalanine concentrations and incubation times on dopamine release, were extensively studied. The results show that our system is well suited for biologists to study chemical release from living cells as well as drug effects on secreting cells. The current system also shows a potential for further improvements toward a multichip array system for drug screening applications.

  4. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets

    DEFF Research Database (Denmark)

    Pantelic, J.; Tham, K. W.; Licina, Dusan

    2015-01-01

    manikin at distances between 1 and 4m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced......The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal...

  5. A New Environmentally Safe Formulation and of Low Cost for Prolonged Release System of Atrazine and Diuron

    Directory of Open Access Journals (Sweden)

    Gracy karla da Rocha Cortes

    2017-07-01

    Full Text Available Diuron and atrazine were incorporated in new formulations developed with the purpose to improve herbicides action through release systems, as well as to reduce the environmental toxicity. A low cost formulation (ALG/ESC was obtained by combining sodium alginate (ALG with fish scales of the Piau fish (ESC from the Leporinus elongatus species. From the crosslinking of ALG/ESC with CaCl2, the formulation ALG/ESC-CaCl2 was obtained. For ALG/ESC-CaCl2, the results are successful, showing a prolonged release of 3.5 and 4.5 days for atrazine and diuron, respectively. Based on parameters of an empirical equation used to fit the herbicide release data, it appears that the release systems of diuron and atrazine from ALG/ESC-CaCl2 are by diffusion processes due to anomalous transport, which did not follow Fick’s laws of diffusion. DOI: http://dx.doi.org/10.17807/orbital.v9i3.994

  6. Self-Consistent System of Equations for a Kinetic Description of the Low-Pressure Discharges Accounting for the Nonlocal and Collisionless Electron Dynamics

    International Nuclear Information System (INIS)

    Kaganovich, Igor D.; Polomarov, Oleg

    2003-01-01

    In low-pressure discharges, when the electron mean free path is larger or comparable with the discharge length, the electron dynamics is essentially non-local. Moreover, the electron energy distribution function (EEDF) deviates considerably from a Maxwellian. Therefore, an accurate kinetic description of the low-pressure discharges requires knowledge of the non-local conductivity operator and calculation of the non-Maxwellian EEDF. The previous treatments made use of simplifying assumptions: a uniform density profile and a Maxwellian EEDF. In the present study a self-consistent system of equations for the kinetic description of nonlocal, non-uniform, nearly collisionless plasmas of low-pressure discharges is derived. It consists of the nonlocal conductivity operator and the averaged kinetic equation for calculation of the non-Maxwellian EEDF. The importance of accounting for the non-uniform plasma density profile on both the current density profile and the EEDF is demonstrated

  7. A Dietary Feedback System for the Delivery of Consistent Personalized Dietary Advice in the Web-Based Multicenter Food4Me Study.

    Science.gov (United States)

    Forster, Hannah; Walsh, Marianne C; O'Donovan, Clare B; Woolhead, Clara; McGirr, Caroline; Daly, E J; O'Riordan, Richard; Celis-Morales, Carlos; Fallaize, Rosalind; Macready, Anna L; Marsaux, Cyril F M; Navas-Carretero, Santiago; San-Cristobal, Rodrigo; Kolossa, Silvia; Hartwig, Kai; Mavrogianni, Christina; Tsirigoti, Lydia; Lambrinou, Christina P; Godlewska, Magdalena; Surwiłło, Agnieszka; Gjelstad, Ingrid Merethe Fange; Drevon, Christian A; Manios, Yannis; Traczyk, Iwona; Martinez, J Alfredo; Saris, Wim H M; Daniel, Hannelore; Lovegrove, Julie A; Mathers, John C; Gibney, Michael J; Gibney, Eileen R; Brennan, Lorraine

    2016-06-30

    Despite numerous healthy eating campaigns, the prevalence of diets high in saturated fatty acids, sugar, and salt and low in fiber, fruit, and vegetables remains high. With more people than ever accessing the Internet, Web-based dietary assessment instruments have the potential to promote healthier dietary behaviors via personalized dietary advice. The objectives of this study were to develop a dietary feedback system for the delivery of consistent personalized dietary advice in a multicenter study and to examine the impact of automating the advice system. The development of the dietary feedback system included 4 components: (1) designing a system for categorizing nutritional intakes; (2) creating a method for prioritizing 3 nutrient-related goals for subsequent targeted dietary advice; (3) constructing decision tree algorithms linking data on nutritional intake to feedback messages; and (4) developing personal feedback reports. The system was used manually by researchers to provide personalized nutrition advice based on dietary assessment to 369 participants during the Food4Me randomized controlled trial, with an automated version developed on completion of the study. Saturated fatty acid, salt, and dietary fiber were most frequently selected as nutrient-related goals across the 7 centers. Average agreement between the manual and automated systems, in selecting 3 nutrient-related goals for personalized dietary advice across the centers, was highest for nutrient-related goals 1 and 2 and lower for goal 3, averaging at 92%, 87%, and 63%, respectively. Complete agreement between the 2 systems for feedback advice message selection averaged at 87% across the centers. The dietary feedback system was used to deliver personalized dietary advice within a multi-country study. Overall, there was good agreement between the manual and automated feedback systems, giving promise to the use of automated systems for personalizing dietary advice. Clinicaltrials.gov NCT01530139

  8. Secondary effects of anion exchange on chloride, sulfate, and lead release: systems approach to corrosion control.

    Science.gov (United States)

    Willison, Hillary; Boyer, Treavor H

    2012-05-01

    Water treatment processes can cause secondary changes in water chemistry that alter finished water quality including chloride, sulfate, natural organic matter (NOM), and metal release. Hence, the goal of this research was to provide an improved understanding of the chloride-to-sulfate mass ratio (CSMR) with regards to chloride and sulfate variations at full-scale water treatment plants and corrosion potential under simulated premise plumbing conditions. Laboratory corrosion studies were conducted using Pb-Sn solder/Cu tubing galvanic cells exposed to model waters with low (approx. 5 mg/L Cl(-) and 10 mg/L SO(4)(2-)) and high (approx. 50 mg/L Cl(-) and 100 mg/L SO(4)(2-)) concentrations of chloride and sulfate at a constant CSMR of ≈ 0.5. The role of NOM during corrosion was also evaluated by changing the type of organic material. In addition, full-scale sampling was conducted to quantify the raw water variability of chloride, sulfate, and NOM concentrations and the changes to these parameters from magnetic ion exchange treatment. Test conditions with higher concentrations of chloride and sulfate released significantly more lead than the lower chloride and sulfate test waters. In addition, the source of NOM was a key factor in the amount of lead released with the model organic compounds yielding significantly less lead release than aquatic NOM. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Effect of light and temperature on circadian system controlling sperm release in moth Spodoptera littoralis

    Czech Academy of Sciences Publication Activity Database

    Syrová, Zdeňka; Šauman, Ivo; Giebultowicz, J. M.

    2003-01-01

    Roč. 20, č. 5 (2003), s. 809-821 ISSN 0742-0528 R&D Projects: GA AV ČR IAA5007205 Institutional research plan: CEZ:AV0Z5007907 Keywords : Insects * sperm release rhythm * peripheral clock Subject RIV: ED - Physiology Impact factor: 1.590, year: 2003

  10. SPEEDI: a computer code system for the real-time prediction of radiation dose to the public due to an accidental release

    International Nuclear Information System (INIS)

    Imai, Kazuhiko; Chino, Masamichi; Ishikawa, Hirohiko

    1985-10-01

    SPEEDI, a computer code system for prediction of environmental doses from radioactive materials accidentally released from a nuclear plant has been developed to assist the organizations responsible for an emergency planning. For realistic simulation, have been developed a model which statistically predicts the basic wind data and then calculates the three-dimensional mass consistent wind field by interpolating these predicted data, and a model for calculation of the diffusion of released materials using a combined model of random-walk and PICK methods. These calculation in the system is carried out in conversational mode with a computer so that we may use the system with ease in an emergency. SPEEDI has also versatile files, which make it easy to control the complicated flows of calculation. In order to attain a short computation time, a large-scale computer with performance of 25 MIPS and a vector processor of maximum 250 MFLOPS are used for calculation of the models so that quick responses have been made. Simplified models are also prepared for calculation in a minicomputer widely used by local governments and research institutes, although the precision of calculation as same with the above models can not be expected to obtain. The present report outlines the structure and functions of SPEEDI, methods for prediction of the wind field and the models for calculation of the concentration of released materials in air and on the ground, and the doses to the public. Some of the diffusion models have been compared with the field experiments which had been carried out as a part of the SPEEDI development program. The report also discusses the reliability of the diffusion models on the basis of the compared results, and shows that they can reasonably simulate the diffusion in the internal boundary layer which commonly occurs near the coastal region. (J.P.N.)

  11. Consistent classical supergravity theories

    International Nuclear Information System (INIS)

    Muller, M.

    1989-01-01

    This book offers a presentation of both conformal and Poincare supergravity. The consistent four-dimensional supergravity theories are classified. The formulae needed for further modelling are included

  12. LEVONORGESTREL-RELEASING INTRAUTERINE SYSTEM AS AN ALTERNATIVE THERAPY IN ABNORMAL UTERINE BLEEDING

    Directory of Open Access Journals (Sweden)

    Kunjamma Roy

    2017-05-01

    interval of 1 month, 3 months and 6 months. RESULTS There is a statistical improvement in the Hb level from the 3 rd month of insertion of LNG-IUS (p >0.005. At the commencement of study, the mean score of Hb among experimental group was 10.52 g% as against 10.16 g% among the control group. While at 1 month, it was found to be 10.98 g% as against 10.34 g% among the control group. At the third month, it was 11.53 g% as against 10.58 g% and at 6 months, it was 11.76 g% as against 10.87 g%. The amount of blood loss was also found to be decreased in the IUS group. The mean amount of blood loss at the commencement of the study in the experimental group and control group were 117 mL as against 114.4 mL, while at 1 month it was 100.8 mL as against 102.24 mL in control group. After 3 months, the blood loss was 78.2 mL as against 93 mL in control group. At 6 months, it was 62.27 mL as against 83.08 mL. CONCLUSION The use of Levonorgestrel releasing intrauterine system (LNG IUS is found to be effective in controlling menstrual blood loss and thus achieving higher Hb levels.

  13. Oxygen enhancement of groundwater using an oxygen releasing compound in a funnel-and-gate system

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, D G

    1994-01-01

    ORC is a fine white MgO[sub 2] powder treated with a patented process so that a slow, relatively steady release of oxygen occurs when the powder is in contact with water. Recent work suggests ORC could potentially be used to increase the dissolved oxygen (DO) concentration of ground water, thereby enhancing the biodegradation of dissolved phase contaminants such as benzene and toluene from gasoline spills. Field and laboratory tests were performed to evaluate the oxygen release characteristics of ORC when mixed with filter sand and exposed to groundwater from an aquifer in Ontario. Quasi steady state oxygen release rates of 0.013-0.030 and 0.030 mg O[sub 2]/d per g of ORC were determined from the column and field tests respectively. The column tests indicated that steady state oxygen release conditions from the ORC required ca 90 d after initial contact with water, but field data indicated that oxygen release rate may continue to decrease. Falling head permeameter tests indicated that a maximum drop in hydraulic conductivity occurred within the first 48 h of exposure of ORC to water. Both laboratory and field studies indicated that ORC-contacted water increased in pH. Field studies further suggested an inverse correlation between pH increases and the ability of ORC to enhance DO concentration of ground water. The use of ORC in a funnel-and-gate scheme appears to be an effective means of increasing the DO concentration in ground water, thereby stimulating the in-situ bioremediation of many organic contaminants. 30 refs., 17 figs., 12 tabs.

  14. Short- and Long-Term Lead Release after Partial Lead Service Line Replacements in a Metropolitan Water Distribution System.

    Science.gov (United States)

    Deshommes, Elise; Laroche, Laurent; Deveau, Dominique; Nour, Shokoufeh; Prévost, Michèle

    2017-09-05

    Thirty-three households were monitored in a full-scale water distribution system, to investigate the impact of recent (sampling over a period of 1-20 months. Point-of-entry filters were installed to capture sporadic release of particulate lead from the lead service lines (LSLs). Mean concentrations increased immediately after PLSLRs and erratic particulate lead spikes were observed over the 18 month post-PLSLR monitoring period. The mass of lead released during this time frame indicates the occurrence of galvanic corrosion and scale destabilization. System-wide, lead concentrations were however lower in households with PLSLRs as compared to those with no replacement, especially for old PLSLRs. Nonetheless, 61% of PLSLR samples still exceeded 10 μg/L, reflecting the importance of implementing full LSL replacement and efficient risk communication. Acute concentrations measured immediately after PLSLRs demonstrate the need for appropriate flushing procedures to prevent lead poisoning.

  15. Quasiparticles and thermodynamical consistency

    International Nuclear Information System (INIS)

    Shanenko, A.A.; Biro, T.S.; Toneev, V.D.

    2003-01-01

    A brief and simple introduction into the problem of the thermodynamical consistency is given. The thermodynamical consistency relations, which should be taken into account under constructing a quasiparticle model, are found in a general manner from the finite-temperature extension of the Hellmann-Feynman theorem. Restrictions following from these relations are illustrated by simple physical examples. (author)

  16. Characterization of a poly(ether urethane)-based controlled release membrane system for delivery of ketoprofen

    International Nuclear Information System (INIS)

    Macocinschi, Doina; Filip, Daniela; Vlad, Stelian; Oprea, Ana Maria; Gafitanu, Carmen Anatolia

    2012-01-01

    Highlights: ► Ketoprofen incorporation in poly(ether urethane) microporous membrane. ► Moisture sorption properties of as-cast membrane. ► Drug release mechanisms in function of pH and composition of membranes. - Abstract: A poly(ether urethane) based on polytetrahydrofuran containing hydroxypropyl cellulose for biomedical applications was tested for its biocompatibility. Ketoprofen was incorporated (3% and 6%) in the polyurethane matrix as an anti-inflammatory drug. Kinetic and drug release mechanisms were studied. The pore size and pore size distribution of the polyurethane membranes were investigated by scanning electron microscopy. Surface tension characteristics as well as moisture sorption properties such as diffusion coefficients and equilibrium moisture contents of the membrane material were studied. It was found that kinetics and release mechanisms are in function of medium pH, composition of polymer–drug system, pore morphology and pore size distribution. Prolonged nature of release of ketoprofen is assured by low amount of drug in polyurethane membrane and physiological pH.

  17. Resolution of methylphenidate osmotic release oral system-induced hair loss in two siblings after dose escalation.

    Science.gov (United States)

    Ardic, Ulku Akyol; Ercan, Eyup Sabri

    2017-11-01

    This report describes the cases of two siblings who experienced hair loss after treatment with methylphenidate (MPH) osmotic release oral system (OROS). Hair loss was resolved after discontinuation of the drug, but the children re-initiated treatment, after which hair loss again occurred, but they continued the treatment. After dose escalation, the hair loss resolved. This is the first report to describe resolution of OROS-MPH-induced hair loss after dose escalation. © 2017 Japan Pediatric Society.

  18. Review of available data on the release, transport and deposition of corrosion products in PWR, BWR and SGHWR systems

    International Nuclear Information System (INIS)

    Taylor, N.K.

    1976-03-01

    A survey has been carried out of data which are relevant to the theoretical and experimental aspects of corrosion product release, transport, activation and deposition and which were available from operational experience of water reactors and associated experiments. The data have been assessed in connection with commercial SGHWR systems with regard to construction, commissioning and operational procedures. A few areas of work where the existing evidence is inconclusive or incomplete are listed. (author)

  19. Chemical form of tritium released from solid breeder materials and the influences of it on a bred tritium recovery systems

    International Nuclear Information System (INIS)

    Furukubo, Y.; Nishikawa, M.; Nishida, Y.; Kinjyo, T.; Tanifuji, Takaaki; Kawamura, Yoshinori; Enoeda, Mikio

    2004-01-01

    The ratio of HTO in total tritium was measured at release of the bred tritium to the purge gas with hydrogen using the thermal release after irradiation method, where neutron irradiation was performed at JRR-3 reactor in JAERI or KUR reactor in Kyoto University. It is experimentally confirmed in this study that not a small portion of bred tritium is released to the purge gas in the form of HTO form ceramic breeder materials even when hydrogen is added to the purge gas. The chemical composition is to be decided by the competitive reaction at the grain surface of a ceramic breeder material where desorption reaction, isotope exchange reaction 1, isotope exchange reaction 2 and water formation reaction are considered to take part. Observation in this study implies that it is necessary to have a bred tritium recovery system applicable for both HT and HTO form to recover whole bred tritium. The chemical composition also decides the amount of tritium transferable to the cooling water of the electricity generation system through the structural material in the blanket system. Permeation behavior of tritium through some structural materials at various conditions are also discussed. (author)

  20. Effects of membrane composition on release of model hydrophilic compound from osmotic delivery systems.

    Science.gov (United States)

    Ozdemir, N; Ozalp, Y; Ozkan, Y

    2000-01-01

    In this study, the effects of surface-active agents in different types and concentrations, added into the coating solution, on release of model hydrophilic compound have been examined. For this purpose, the tablets, prepared with the use of methylene blue as a model substance, were coated by spray coating technique with cellulose acetate solution containing polyethylene glycol 400 as a plasticizer. In addition, cetylpyridinium chloride as cationic surface-active agent and sodium lauryl sulphate as anionic surface-active agent were added into coating solution in different concentrations. After creating a delivery orifice by a microdrill on the tablets, release of model hydrophilic compound was tested by the USP paddle method. The data obtained were evaluated according to the different kinetics and the mechanism of release from the preparations was examined. The surface properties of the coating material were investigated by scanning electron microscope taken before and after the contact with medium fluid, as well as the mechanical properties by tensile tests. In conclusion, it has been found that the cationic surface active agent, cetylpyridinium chloride reduced the lag time, observed during the release of model hydrophilic compound, as a result of its enhancing effect on wettability of tablets by reducing the contact angle between the medium fluid and the coating material. On the other hand, the anionic surface active agent, sodium lauryl sulphate has been inactivated possibly due to the interaction with model hydrophilic compound that has cationic properties and/or substances contained in membrane composition; thus, the lag time has not decreased and furthermore, a significant decrease in the delivery rate of model hydrophilic compound has been observed.

  1. A mRNA-Responsive G-Quadruplex-Based Drug Release System

    Directory of Open Access Journals (Sweden)

    Hidenobu Yaku

    2015-04-01

    Full Text Available G-quadruplex-based drug delivery carriers (GDDCs were designed to capture and release a telomerase inhibitor in response to a target mRNA. Hybridization between a loop on the GDDC structure and the mRNA should cause the G-quadruplex structure of the GDDC to unfold and release the bound inhibitor, anionic copper(II phthalocyanine (CuAPC. As a proof of concept, GDDCs were designed with a 10-30-mer loop, which can hybridize with a target sequence in epidermal growth factor receptor (EGFR mRNA. Structural analysis using circular dichroism (CD spectroscopy showed that the GDDCs form a (3 + 1 type G-quadruplex structure in 100 mM KCl and 10 mM MgCl2 in the absence of the target RNA. Visible absorbance titration experiments showed that the GDDCs bind to CuAPC with Ka values of 1.5 × 105 to 5.9 × 105 M−1 (Kd values of 6.7 to 1.7 μM at 25 °C, depending on the loop length. Fluorescence titration further showed that the G-quadruplex structure unfolds upon binding to the target RNA with Ka values above 1.0 × 108 M−1 (Kd values below 0.01 μM at 25 °C. These results suggest the carrier can sense and bind to the target RNA, which should result in release of the bound drug. Finally, visible absorbance titration experiments demonstrated that the GDDC release CuAPC in response to the target RNA.

  2. Progesterone PLGA/mPEG-PLGA Hybrid Nanoparticle Sustained-Release System by Intramuscular Injection.

    Science.gov (United States)

    Xie, Bin; Liu, Yang; Guo, Yuting; Zhang, Enbo; Pu, Chenguang; He, Haibing; Yin, Tian; Tang, Xing

    2018-02-14

    To prepare sustained-release PLGA/mPEG-PLGA hybrid nanoparticles of progesterone (PRG), and evaluate the descending required administration dosage in vivo. PRG hybrid nanoparticles (PRG H-NPs) based on PLGA/mPEG-PLGA were compared with PRG nanoparticles (PRG-NPs) of pure PLGA as the matrix and PRG-oil solutions. Nanoparticles (NPs) were formed by the method of nanoemulsion, and the pharmacokinetics of the sustained-release PRG H-NPs in male Sprague dawley (SD) rats were investigated. The rats were randomly divided into four groups, each group received: single dose of PRG H-NPs (14.58 mg/kg, i.m.) and PRG-NPs (14.58 mg/kg, i.m.), repeated dosing for 7 days of PRG-oil (2.08 mg/kg, i.m.) solution (Oil-L) and a higher dosage of PRG-oil (6.24 mg/kg, i.m.) solution (Oil-H), respectively. In the pharmacokinetic test, the PRG H-NPs exhibited a comparatively good sustained-release effect against the PRG-NPs without mPEG-PLGA and PRG-oil solution. The pharmacokinetic parameters of the PRG H-NPs, PRG-NPs, Oil-L and Oil-H were AUC 0-t (ng·h·mL -1 ) 8762.1, 1546.1, 1914.5, and 12,138.9, t 1/2 (h)52.7, 44.1, 8.4 and 44.6 respectively. Owing to the modification of PEG, PRG H-NPs can act as safe delivery platforms for sustained-release of drugs with a lower dosage required.

  3. Hydrogen radiolytic release from zeolite 4A/water systems under γ irradiations

    International Nuclear Information System (INIS)

    Frances, Laëtitia; Grivet, Manuel; Renault, Jean-Philippe; Groetz, Jean-Emmanuel; Ducret, Didier

    2015-01-01

    Although the radiolysis of bulk water is well known, some questions remain in the case of adsorbed or confined water, especially in the case of zeolites 4A, which are used to store tritiated water. An enhancement of the production of hydrogen is described in the literature for higher porous structures, but the phenomenon stays unexplained. We have studied the radiolysis of zeolites 4A containing different quantities of water under 137 Cs gamma radiation. We focused on the influence of the water loading ratio. The enhancement of hydrogen production compared with bulk water radiolysis has been attributed to the energy transfer from the zeolite to the water, and to the influence of the water structure organization in the zeolite. Both were observed separately, with a maximum efficiency for energy transfer at a loading ratio of about 13%, and a maximum impact of structuration of water at a loading ratio of about 4%. - Highlights: • We irradiated samples of zeolites 4A which contained different quantities of water. • We measured the quantity of hydrogen released. • Hydrogen radiolytic yields, present two maxima, for two water loading ratios. • Hydrogen release is enhanced by the strength of the zeolite/water interaction. • Hydrogen release is enhanced by the quantity of water interacting with the zeolite

  4. A study of the 51Cr release assay system in micro-method

    International Nuclear Information System (INIS)

    Kiya, Katsuzo; Harada, Kiyoshi; Uozumi, Tohru; Toge, Tetsuya; Hattori, Takao.

    1981-01-01

    Conditions of 51 Cr release assay in microculture were investigated to measure the natural cytotoxic (NC) activity of mouse spleen cells. Malignant glioma (MG) cells of C57BL/6 mouse, induced by 20-methylcholanthrene, were labeled with Na 2 51 CrO 4 . Spleen cells collected from the same mouse strain were suspended in Eagle's MEM. Labeled MG cells and spleen cells were incubated for several hours in a CO 2 incubator. Then the activity of the supernatant was measured by an automatic gamma counter. The optimum conditions of 51 Cr release assay in micro-culture were, (1) number of the target cells: 5 x 10 3 / well (2) FCS concentration: 10% (3) E/T ratio: less than 100 : 1, 50 : 1 was possible (4) incubation time: 15 hours. The number of the target cells at labeling incubation was set to 2 x 10 6 /ml. Though the natural release of 51 Cr was not effected by the viability of the target cells, it was suggested that the NC activity was dependent on the viability of both cells, target and effector cells. (Tsunoda, M.)

  5. Study of the /sup 51/Cr release assay system in micro-method

    Energy Technology Data Exchange (ETDEWEB)

    Kiya, K.; Harada, K.; Uozumi, T. (Hiroshima Univ. (Japan). School of Medicine); Toge, T.; Hattori, T.

    1981-05-01

    Conditions of /sup 51/Cr release assay in microculture were investigated to measure the natural cytotoxic (NC) activity of mouse spleen cells. Malignant glioma (MG) cells of C57BL/6 mouse, induced by 20-methylcholanthrene, were labeled with Na/sub 2//sup 51/CrO/sub 4/. Spleen cells collected from the same mouse strain were suspended in Eagle's MEM. Labeled MG cells and spleen cells were incubated for several hours in a CO/sub 2/ incubator. Then the activity of the supernatant was measured by an automatic gamma counter. The optimum conditions of /sup 51/Cr release assay in micro-culture were, (1) number of the target cells: 5 x 10/sup 3// well (2) FCS concentration: 10% (3) E/T ratio: less than 100 : 1, 50 : 1 was possible (4) incubation time: 15 hours. The number of the target cells at labeling incubation was set to 2 x 10/sup 6//ml. Though the natural release of /sup 51/Cr was not effected by the viability of the target cells, it was suggested that the NC activity was dependent on the viability of both cells, target and effector cells.

  6. Mini-tablets versus pellets as promising multiparticulate modified release delivery systems for highly soluble drugs.

    Science.gov (United States)

    Gaber, Dina M; Nafee, Noha; Abdallah, Osama Y

    2015-07-05

    Whether mini-tablets (tablets, diameters ≤6mm) belong to single- or multiple-unit dosage forms is still questionable. Accordingly, Pharmacopoeial evaluation procedures for mini-tablets are lacking. In this study, the aforementioned points were discussed. Moreover, their potential for oral controlled delivery was assessed. The antidepressant venlafaxine hydrochloride (Vx), a highly soluble drug undergoing first pass effect, low bioavailability and short half-life was selected as a challenging payload. In an attempt to weigh up mini-tablets versus pellets as multiparticulate carriers, Vx-loaded mini-tablets were compared to formulated pellets of the same composition and the innovator Effexor(®)XR pellets. Formulations were prepared using various polymer hydrogels in the core and ethyl cellulose film coating with increasing thickness. Mini-tablets (diameter 2mm) showed extended Vx release (<60%, 8h). Indeed, release profiles comparable to Effexor(®)XR pellets were obtained. Remarkably higher coating thickness was required for pellets to provide equivalent retardation. Ethyl cellulose in the core ensured faster release due to polymer migration to the surface and pore formation in the coat. mini-tablets showed higher stability to pellets upon storage. Industrially speaking, mini-tablets proved to be superior to pellets in terms of manufacturing, product quality and economical aspects. Results point out the urgent need for standardized evaluation procedures for mini-tablets. Copyright © 2015. Published by Elsevier B.V.

  7. Sustained Release and Cytotoxicity Evaluation of Carbon Nanotube-Mediated Drug Delivery System for Betulinic Acid

    Directory of Open Access Journals (Sweden)

    Julia M. Tan

    2014-01-01

    Full Text Available Carbon nanotubes (CNTs have been widely utilized as a novel drug carrier with promising future applications in biomedical therapies due to their distinct characteristics. In the present work, carboxylic acid-functionalized single-walled carbon nanotubes (f-SWCNTs were used as the starting material to react with anticancer drug, BA to produce f-SWCNTs-BA conjugate via π-π stacking interaction. The conjugate was extensively characterized for drug loading capacity, physicochemical properties, surface morphology, drug releasing characteristics, and cytotoxicity evaluation. The results indicated that the drug loading capacity was determined to be around 20 wt% and this value has been verified by thermogravimetric analysis. The binding of BA onto the surface of f-SWCNTs was confirmed by FTIR and Raman spectroscopies. Powder XRD analysis showed that the structure of the conjugate was unaffected by the loading of BA. The developed conjugate was found to release the drug in a controlled manner with a prolonged release property. According to the preliminary in vitro cytotoxicity studies, the conjugate was not toxic in a standard fibroblast cell line, and anticancer activity was significantly higher in A549 than HepG2 cell line. This study suggests that f-SWCNTs could be developed as an efficient drug carrier to conjugate drugs for pharmaceutical applications in cancer chemotherapies.

  8. A hybrid numerical model system of LCO2 and CO2 enriched seawater dynamics in the ocean induced by moving-ship releasing

    International Nuclear Information System (INIS)

    Chen, B.; Song, Y.; Ohsumi, T.; AIST, Ibaraki; Nishio, M.; Akai, M.

    2004-01-01

    A numerical modeling system has been developed, based on an engineering background, of the direct disposal of liquid carbon dioxide into the ocean by a moving-ship, to predict the physico-chemical dynamics of liquid carbon dioxide droplets and carbon dioxide enriched seawater in the ocean. This is a hybrid simulation model system consisting of a three-dimensional small-scale near-field model and a two-dimensional horizontal turbulent dispersion model. The dynamics near to release sites include double-plume creation, interaction, evolution, and coupling with ocean currents; these are described by using two-fluid large-eddy simulation technology. The further development of carbon dioxide enriched seawater, as a passive-inert scalar, in relatively larger spatial and time scales (28x28 km and up to 100 h) is then simulated by a horizontal turbulent dispersion model. For the case of liquid carbon dioxide release at a depth of 2000 m with mass flow rate of 100 kg/s and initial droplet diameter of 8.0 mm, and with ship speed of 3.0 m/s, the model predicts a vertically separated carbon dioxide enriched seawater plume, 330 m in height and 40 m in width at time about 1 h after release with a minimum pH of 6.20 corresponding to carbon dioxide concentration of 0.18 kg/m 3 , in the surrounding area. This carbon dioxide enriched seawater plume diffused turbulently in the horizontal surface to an area of 9.8x10.5 km 2 after 100 h. (author)

  9. Assessing the impact of releases of radionuclides into sewage systems in urban environment - simulation, modelling and experimental studies - LUCIA

    International Nuclear Information System (INIS)

    Sundelll-Bergman, S.; Avila, R.; Cruz, I. de la; Xu, S.; Puhakainen, M.; Heikkinene, T.; Rahola, T.; Hosseini, A.; Nielsen, Sven; Sigurgeirsson, M.

    2009-06-01

    This report summarises the findings of a project on assessing the impact of releases of radionuclides into sewage systems and was established to provide more knowledge and suitable tools for emergency preparedness purposes in urban areas. It was known that the design of sewage plants, and their wastewater treatments, is rather similar between the Nordic countries. One sewage plant in each of the five Nordic countries was selected for assessing the impact of radionuclide releases from hospitals into their sewerage systems. Measurements and model predictions of dose assessments to different potentially exposed members of the public were carried out. The results from the dose assessments indicate that in case of routine releases annual doses to the three hypothetical groups of individuals are most likely insignificant. Estimated doses for workers are below 10 μSv/y, for the two studied radionuclides 99mTc and 131I. If uncertainties in the predictions of activity concentrations in sludge are considered, then the probability of obtaining doses above 10 μSv/y may not be insignificant. The models and approaches developed can also be applied in case of accidental releases. A laboratory inter-comparison exercise was also organised to compare analytical results across the laboratories participating in the project, using both 131I, dominating man-made radionuclide in sewage systems due to the medical use. A process oriented model of the biological treatment is also proposed in the report that does not require as much input data as for the LUCIA model. This model is a combination of a simplified well known Activated Sludge Model No.1 (Henze, 1987) and the Kd concept used in the LUCIA model. The simplified model is able to estimate the concentrations and the retention time of the sludge in different parts of the treatment plant, which in turn, can be used as a tool for the dose assessment purpose.filled by the activity. (au)

  10. Assessing the impact of releases of radionuclides into sewage systems in urban environment - simulation, modelling and experimental studies - LUCIA

    Energy Technology Data Exchange (ETDEWEB)

    Sundelll-Bergman, S. (Vattenfall Power Consultant, Stockholm (Sweden)); Avila, R.; Cruz, I. de la (Facilia AB, (Sweden)); Xu, S. (Swedish Radiation Safety Authority, (Sweden)); Puhakainen, M.; Heikkinene, T.; Rahola, T. (STUK (Finland)); Hosseini, A. (Norwegian Radiation Protection Authority (Norway)); Nielsen, Sven (Risoe National Laboratory for Sustainable Energy, DTU (Denmark)); Sigurgeirsson, M. (Geislavarnir rikisins (Iceland))

    2009-06-15

    This report summarises the findings of a project on assessing the impact of releases of radionuclides into sewage systems and was established to provide more knowledge and suitable tools for emergency preparedness purposes in urban areas. It was known that the design of sewage plants, and their wastewater treatments, is rather similar between the Nordic countries. One sewage plant in each of the five Nordic countries was selected for assessing the impact of radionuclide releases from hospitals into their sewerage systems. Measurements and model predictions of dose assessments to different potentially exposed members of the public were carried out. The results from the dose assessments indicate that in case of routine releases annual doses to the three hypothetical groups of individuals are most likely insignificant. Estimated doses for workers are below 10 muSv/y, for the two studied radionuclides 99mTc and 131I. If uncertainties in the predictions of activity concentrations in sludge are considered, then the probability of obtaining doses above 10 muSv/y may not be insignificant. The models and approaches developed can also be applied in case of accidental releases. A laboratory inter-comparison exercise was also organised to compare analytical results across the laboratories participating in the project, using both 131I, dominating man-made radionuclide in sewage systems due to the medical use. A process oriented model of the biological treatment is also proposed in the report that does not require as much input data as for the LUCIA model. This model is a combination of a simplified well known Activated Sludge Model No.1 (Henze, 1987) and the Kd concept used in the LUCIA model. The simplified model is able to estimate the concentrations and the retention time of the sludge in different parts of the treatment plant, which in turn, can be used as a tool for the dose assessment purpose.filled by the activity. (au)

  11. Tumor-directed gene therapy in mice using a composite nonviral gene delivery system consisting of the piggyBac transposon and polyethylenimine

    International Nuclear Information System (INIS)

    Kang, Yu; Zhang, Xiaoyan; Jiang, Wei; Wu, Chaoqun; Chen, Chunmei; Zheng, Yufang; Gu, Jianren; Xu, Congjian

    2009-01-01

    Compared with viral vectors, nonviral vectors are less immunogenic, more stable, safer and easier to replication for application in cancer gene therapy. However, nonviral gene delivery system has not been extensively used because of the low transfection efficiency and the short transgene expression, especially in vivo. It is desirable to develop a nonviral gene delivery system that can support stable genomic integration and persistent gene expression in vivo. Here, we used a composite nonviral gene delivery system consisting of the piggyBac (PB) transposon and polyethylenimine (PEI) for long-term transgene expression in mouse ovarian tumors. A recombinant plasmid PB [Act-RFP, HSV-tk] encoding both the herpes simplex thymidine kinase (HSV-tk) and the monomeric red fluorescent protein (mRFP1) under PB transposon elements was constructed. This plasmid and the PBase plasmid were injected into ovarian cancer tumor xenografts in mice by in vivo PEI system. The antitumor effects of HSV-tk/ganciclovir (GCV) system were observed after intraperitoneal injection of GCV. Histological analysis and TUNEL assay were performed on the cryostat sections of the tumor tissue. Plasmid construction was confirmed by PCR analysis combined with restrictive enzyme digestion. mRFP1 expression could be visualized three weeks after the last transfection of pPB/TK under fluorescence microscopy. After GCV admission, the tumor volume of PB/TK group was significantly reduced and the tumor inhibitory rate was 81.96% contrasted against the 43.07% in the TK group. Histological analysis showed that there were extensive necrosis and lymphocytes infiltration in the tumor tissue of the PB/TK group but limited in the tissue of control group. TUNEL assays suggested that the transfected cells were undergoing apoptosis after GCV admission in vivo. Our results show that the nonviral gene delivery system coupling PB transposon with PEI can be used as an efficient tool for gene therapy in ovarian cancer

  12. Self-consistent random phase approximation - application to systems of strongly correlated fermions; Approximation des phases aleatoires self-consistante - applications a des systemes de fermions fortement correles

    Energy Technology Data Exchange (ETDEWEB)

    Jemai, M

    2004-07-01

    In the present thesis we have applied the self consistent random phase approximation (SCRPA) to the Hubbard model with a small number of sites (a chain of 2, 4, 6,... sites). Earlier SCRPA had produced very good results in other models like the pairing model of Richardson. It was therefore interesting to see what kind of results the method is able to produce in the case of a more complex model like the Hubbard model. To our great satisfaction the case of two sites with two electrons (half-filling) is solved exactly by the SCRPA. This may seem a little trivial but the fact is that other respectable approximations like 'GW' or the approach with the Gutzwiller wave function yield results still far from exact. With this promising starting point, the case of 6 sites at half filling was considered next. For that case, evidently, SCRPA does not any longer give exact results. However, they are still excellent for a wide range of values of the coupling constant U, covering for instance the phase transition region towards a state with non zero magnetisation. We consider this as a good success of the theory. Non the less the case of 4 sites (a plaquette), as indeed all cases with 4n sites at half filling, turned out to have a problem because of degeneracies at the Hartree Fock level. A generalisation of the present method, including in addition to the pairs, quadruples of Fermions operators (called second RPA) is proposed to also include exactly the plaquette case in our approach. This is therefore a very interesting perspective of the present work. (author)

  13. LTE-advanced a practical systems approach to understanding 3GPP LTE releases 10 and 11 radio access technologies

    CERN Document Server

    Ahmadi, Sassan

    2013-01-01

    This book is an in-depth, systematic and structured technical reference on 3GPP's LTE-Advanced (Releases 10 and 11), covering theory, technology and implementation, written by an author who has been involved in the inception and development of these technologies for over 20 years. The book not only describes the operation of individual components, but also shows how they fit into the overall system and operate from a systems perspective. Uniquely, this book gives in-depth information on upper protocol layers, implementation and deployment issues, and services, making it suitable for engine

  14. Carbon dioxide diffuse emission and thermal energy release from hydrothermal systems at Copahue-Caviahue Volcanic Complex (Argentina)

    Science.gov (United States)

    Chiodini, Giovanni; Cardellini, Carlo; Lamberti, María Clara; Agusto, Mariano; Caselli, Alberto; Liccioli, Caterina; Tamburello, Giancarlo; Tassi, Franco; Vaselli, Orlando; Caliro, Stefano

    2015-10-01

    The north-western sector of Caviahue caldera (Argentina), close to the active volcanic system of Copahue, is characterized by the presence of several hydrothermal sites that host numerous fumarolic emissions, anomalous soil diffuse degassing of CO2 and hot soils. In March 2014, measurements of soil CO2 fluxes in 5 of these sites (namely, Las Máquinas, Las Maquinitas I, Las Maquinitas II, Anfiteatro, and Termas de Copahue) allowed an estimation that 165 t of deeply derived CO2 is daily released. The gas source is likely related to a relatively shallow geothermal reservoir containing a single vapor phase as also suggested by both the geochemical data from the 3 deep wells drilled in the 1980s and gas geoindicators applied to the fumarolic discharges. Gas equilibria within the H-C-O gas system indicate the presence of a large, probably unique, single phase vapor zone at 200-210 °C feeding the hydrothermal manifestations of Las Máquinas, Las Maquinitas I and II and Termas de Copahue. A natural thermal release of 107 MW was computed by using CO2 as a tracer of the original vapor phase. The magmatic signature of the incondensable fumarolic gases, the wide expanse of the hydrothermal areas and the remarkable high amount of gas and heat released by fluid expulsion seem to be compatible with an active magmatic intrusion beneath this portion of the Caviahue caldera.

  15. Cross-linked chitosan-dextran sulphate vehicle system for controlled release of ciprofloxaxin drug: An ophthalmic application

    Directory of Open Access Journals (Sweden)

    Chetan Chavan

    2017-01-01

    Full Text Available The major challenge associated with conventional eye-drop is the rapid drug loss due to precorneal defence barrier. In this context, controlled-release system of ciprofloxacin-conjugated chitosan (CS-Dextran sulphate (DS nanoparticles (NPs have been synthesized, to increase the bioavailability. The formulated drug delivery vehicle was evaluated for its therapeutic value in the simulated tear fluidat pH 7.4. Ophthalmic microbes were tested with this formulation, to confirm the drug efficacy; which showed conducive therapeutic values of both MIC and MBC. Ocular irritancy test was performed using HET-CAM test, which showed that the CS-DS system did not yield any vascular response, offering it to be a non-irritant to the ocular surface. The release studies showed monotonous controlled-release for duration of 21 h. A fine cross-linking between CS and DS has been demonstrated to form CS-DS NPs and their interaction with drug has been evaluated using conventional characterization tools.

  16. Internal consistency, test-retest reliability and measurement error of the self-report version of the social skills rating system in a sample of Australian adolescents.

    Directory of Open Access Journals (Sweden)

    Sharmila Vaz

    Full Text Available The social skills rating system (SSRS is used to assess social skills and competence in children and adolescents. While its characteristics based on United States samples (US are published, corresponding Australian figures are unavailable. Using a 4-week retest design, we examined the internal consistency, retest reliability and measurement error (ME of the SSRS secondary student form (SSF in a sample of Year 7 students (N = 187, from five randomly selected public schools in Perth, western Australia. Internal consistency (IC of the total scale and most subscale scores (except empathy on the frequency rating scale was adequate to permit independent use. On the importance rating scale, most IC estimates for girls fell below the benchmark. Test-retest estimates of the total scale and subscales were insufficient to permit reliable use. ME of the total scale score (frequency rating for boys was equivalent to the US estimate, while that for girls was lower than the US error. ME of the total scale score (importance rating was larger than the error using the frequency rating scale. The study finding supports the idea of using multiple informants (e.g. teacher and parent reports, not just student as recommended in the manual. Future research needs to substantiate the clinical meaningfulness of the MEs calculated in this study by corroborating them against the respective Minimum Clinically Important Difference (MCID.

  17. Internal consistency, test-retest reliability and measurement error of the self-report version of the social skills rating system in a sample of Australian adolescents.

    Science.gov (United States)

    Vaz, Sharmila; Parsons, Richard; Passmore, Anne Elizabeth; Andreou, Pantelis; Falkmer, Torbjörn

    2013-01-01

    The social skills rating system (SSRS) is used to assess social skills and competence in children and adolescents. While its characteristics based on United States samples (US) are published, corresponding Australian figures are unavailable. Using a 4-week retest design, we examined the internal consistency, retest reliability and measurement error (ME) of the SSRS secondary student form (SSF) in a sample of Year 7 students (N = 187), from five randomly selected public schools in Perth, western Australia. Internal consistency (IC) of the total scale and most subscale scores (except empathy) on the frequency rating scale was adequate to permit independent use. On the importance rating scale, most IC estimates for girls fell below the benchmark. Test-retest estimates of the total scale and subscales were insufficient to permit reliable use. ME of the total scale score (frequency rating) for boys was equivalent to the US estimate, while that for girls was lower than the US error. ME of the total scale score (importance rating) was larger than the error using the frequency rating scale. The study finding supports the idea of using multiple informants (e.g. teacher and parent reports), not just student as recommended in the manual. Future research needs to substantiate the clinical meaningfulness of the MEs calculated in this study by corroborating them against the respective Minimum Clinically Important Difference (MCID).

  18. Bimatoprost-loaded ocular inserts as sustained release drug delivery systems for glaucoma treatment: in vitro and in vivo evaluation.

    Directory of Open Access Journals (Sweden)

    Juçara Ribeiro Franca

    Full Text Available The purpose of the present study was to develop and assess a novel sustained-release drug delivery system of Bimatoprost (BIM. Chitosan polymeric inserts were prepared using the solvent casting method and characterized by swelling studies, infrared spectroscopy, differential scanning calorimetry, drug content, scanning electron microscopy and in vitro drug release. Biodistribution of 99mTc-BIM eye drops and 99mTc-BIM-loaded inserts, after ocular administration in Wistar rats, was accessed by ex vivo radiation counting. The inserts were evaluated for their therapeutic efficacy in glaucomatous Wistar rats. Glaucoma was induced by weekly intracameral injection of hyaluronic acid. BIM-loaded inserts (equivalent to 9.0 µg BIM were administered once into conjunctival sac, after ocular hypertension confirmation. BIM eye drop was topically instilled in a second group of glaucomatous rats for 15 days days, while placebo inserts were administered once in a third group. An untreated glaucomatous group was used as control. Intraocular pressure (IOP was monitored for four consecutive weeks after treatment began. At the end of the experiment, retinal ganglion cells and optic nerve head cupping were evaluated in the histological eye sections. Characterization results revealed that the drug physically interacted, but did not chemically react with the polymeric matrix. Inserts sustainedly released BIM in vitro during 8 hours. Biodistribution studies showed that the amount of 99mTc-BIM that remained in the eye was significantly lower after eye drop instillation than after chitosan insert implantation. BIM-loaded inserts lowered IOP for 4 weeks, after one application, while IOP values remained significantly high for the placebo and untreated groups. Eye drops were only effective during the daily treatment period. IOP results were reflected in RGC counting and optic nerve head cupping damage. BIM-loaded inserts provided sustained release of BIM and seem to be a

  19. Gravitation Theory: Empirical Status from Solar System Experiments: All observations to date are consistent with Einstein's general relativity theory of gravity.

    Science.gov (United States)

    Nordtvedt, K L

    1972-12-15

    I have reviewed the historical and contemporary experiments that guide us in choosing a post-Newtonian, relativistic gravitational theory. The foundation experiments essentially constrain gravitation theory to be a metric theory in which matter couples solely to one gravitational field, the metric field, although other cosmological gravitational fields may exist. The metric field for any metric theory can be specified (for the solar system, for our present purposes) by a series of potential terms with several parameters. A variety of experiments specify (or put limits on) the numerical values of the seven parameters in the post-Newtonian metric field, and other such experiments have been planned. The empirical results, to date, yield values of the parameters that are consistent with the predictions of Einstein's general relativity.

  20. Systemic levels of metallic ions released from orthodontic mini-implants.

    Science.gov (United States)

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  1. Simulating Exposure Concentrations of Engineered Nanomaterials in Surface Water Systems: Release of WASP8

    Science.gov (United States)

    Knightes, C. D.; Bouchard, D.; Zepp, R. G.; Henderson, W. M.; Han, Y.; Hsieh, H. S.; Avant, B. K.; Acrey, B.; Spear, J.

    2017-12-01

    The unique properties of engineered nanomaterials led to their increased production and potential release into the environment. Currently available environmental fate models developed for traditional contaminants are limited in their ability to simulate nanomaterials' environmental behavior. This is due to an incomplete understanding and representation of the processes governing nanomaterial distribution in the environment and by scarce empirical data quantifying the interaction of nanomaterials with environmental surfaces. The well-known Water Quality Analysis Simulation Program (WASP) was updated to incorporate nanomaterial-specific processes, specifically hetero-aggregation with particulate matter. In parallel with this effort, laboratory studies were used to quantify parameter values parameters necessary for governing processes in surface waters. This presentation will discuss the recent developments in the new architecture for WASP8 and the newly constructed Advanced Toxicant Module. The module includes advanced algorithms for increased numbers of state variables: chemicals, solids, dissolved organic matter, pathogens, temperature, and salinity. This presentation will focus specifically on the incorporation of nanomaterials, with the applications of the fate and transport of hypothetical releases of Multi-Walled Carbon Nanotubes (MWCNT) and Graphene Oxide (GO) into the headwaters of a southeastern US coastal plains river. While this presentation focuses on nanomaterials, the advanced toxicant module can also simulate metals and organic contaminants.

  2. Thermal stability and microstructure of GMR-systems consisting of thin metallic films; Thermische Stabilitaet und Mikrostruktur von GMR-Systemen aus duennen metallischen Filmen

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Joerg

    2007-08-31

    In this work the short-term and long-term stability of the nanoscale metallic multilayers at elevated temperatures is studied. Reasons and mechanisms for breakdown of the GMR-effect have been analyzed by different physical methods. The multilayered samples investigated in this work exhibit a GMR effect of GMR (alloy)=20.7 % which is significantly smaller than the effect of the standard system with pure Cu interlayers (GMR(Cu)=25.2 %). For protection against oxidation during the use a passivation coating consisting of SiO{sub 2} and Si{sub 3}N{sub 4} has been deposited by the means of plasma CVD. Typical parameters for this process are times of t{sub short-term}=1 h in the temperature range of 200 Csystems will not break down under these conditions. By applying an Arrhenius-relation for the breakdown at the working point WP=12 mT for test sensors with non-alloyed Cu interlayers it was possible to predict a lifetime of t{sub failure}=56000 h for T{sub use}=150 C. Maximum lifetime for the alloyed systems was determined to be t{sub failure}=15000 h. The effective activation energy EA for the breakdown of the tested sensors of the long-term study was laying in the range of 1.4 eV{<=}EA{<=}1.6 eV, indicating for grain boundary diffusion as the dominating mechanism for the structural changes of the multilayered samples. These changes have been verified by applying different techniques like X-ray Reflectivity, Transmission Electron Microscopy, or Moessbauer Spectroscopy to three different combinations of materials: the CoFe/Cu basic system the CoFe/CuAgAu alloyed system the model system consisting of Fe/Cu multilayers The breakdown of the multilayered systems is passing three main stages: Samples examined directly after the preparation show mixing of different atomic species at the interfaces. This intermixing goes along with lattice disturbances, and together they cause an increased basic

  3. Local sustained-release delivery systems of the antibiofilm agent thiazolidinedione-8 for prevention of catheter-associated urinary tract infections.

    Science.gov (United States)

    Shenderovich, Julia; Feldman, Mark; Kirmayer, David; Al-Quntar, Abed; Steinberg, Doron; Lavy, Eran; Friedman, Michael

    2015-05-15

    Thiazolidinedione-8 (TZD-8) is an anti-quorum-sensing molecule that has the potential to effectively prevent catheter-associated urinary tract infections, a major healthcare challenge. Sustained-release drug-delivery systems can enhance drugs' therapeutic potential, by maintaining their therapeutic level and reducing their side effects. Varnishes for sustained release of TZD-8 based on ethylcellulose or ammonio methacrylate copolymer type A (Eudragit(®) RL) were developed. The main factors affecting release rate were found to be film thickness and presence of a hydrophilic or swellable polymer in the matrix. The release mechanism of ethylcellulose-based systems matched the Higuchi model. Selected varnishes were retained on catheters for at least 8 days. Sustained-release delivery systems of TZD-8 were active against Candida albicans biofilms. The present study demonstrates promising results en route to developing applications for the prevention of catheter-associated infections. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Consistency in PERT problems

    OpenAIRE

    Bergantiños, Gustavo; Valencia-Toledo, Alfredo; Vidal-Puga, Juan

    2016-01-01

    The program evaluation review technique (PERT) is a tool used to schedule and coordinate activities in a complex project. In assigning the cost of a potential delay, we characterize the Shapley rule as the only rule that satisfies consistency and other desirable properties.

  5. Consistent data recording across a health system and web-enablement allow service quality comparisons: online data for commissioning dermatology services.

    Science.gov (United States)

    Dmitrieva, Olga; Michalakidis, Georgios; Mason, Aaron; Jones, Simon; Chan, Tom; de Lusignan, Simon

    2012-01-01

    A new distributed model of health care management is being introduced in England. Family practitioners have new responsibilities for the management of health care budgets and commissioning of services. There are national datasets available about health care providers and the geographical areas they serve. These data could be better used to assist the family practitioner turned health service commissioners. Unfortunately these data are not in a form that is readily usable by these fledgling family commissioning groups. We therefore Web enabled all the national hospital dermatology treatment data in England combining it with locality data to provide a smart commissioning tool for local communities. We used open-source software including the Ruby on Rails Web framework and MySQL. The system has a Web front-end, which uses hypertext markup language cascading style sheets (HTML/CSS) and JavaScript to deliver and present data provided by the database. A combination of advanced caching and schema structures allows for faster data retrieval on every execution. The system provides an intuitive environment for data analysis and processing across a large health system dataset. Web-enablement has enabled data about in patients, day cases and outpatients to be readily grouped, viewed, and linked to other data. The combination of web-enablement, consistent data collection from all providers; readily available locality data; and a registration based primary system enables the creation of data, which can be used to commission dermatology services in small areas. Standardized datasets collected across large health enterprises when web enabled can readily benchmark local services and inform commissioning decisions.

  6. Construction of an all-solid-state artificial Z-scheme system consisting of Bi2WO6/Au/CdS nanostructure for photocatalytic CO2 reduction into renewable hydrocarbon fuel

    Science.gov (United States)

    Wang, Meng; Han, Qiutong; Li, Liang; Tang, Lanqin; Li, Haijin; Zhou, Yong; Zou, Zhigang

    2017-07-01

    An all-solid-state Bi2WO6/Au/CdS Z-scheme system was constructed for the photocatalytic reduction of CO2 into methane in the presence of water vapor. This Z-scheme consists of ultrathin Bi2WO6 nanoplates and CdS nanoparticles as photocatalysts, and a Au nanoparticle as a solid electron mediator offering a high speed charge transfer channel and leading to more efficient spatial separation of electron-hole pairs. The photo-generated electrons from the conduction band (CB) of Bi2WO6 transfer to the Au, and then release to the valence band (VB) of CdS to recombine with the holes of CdS. It allows the electrons remaining in the CB of CdS and holes in the VB of Bi2WO6 to possess strong reduction and oxidation powers, respectively, leading the Bi2WO6/Au/CdS to exhibit high photocatalytic reduction of CO2, relative to bare Bi2WO6, Bi2WO6/Au, and Bi2WO6/CdS. The depressed hole density on CdS also enhances the stability of the CdS against photocorrosion.

  7. The nervus terminalis in amphibians: anatomy, chemistry and relationship with the hypothalamic gonadotropin-releasing hormone system.

    Science.gov (United States)

    Muske, L E; Moore, F L

    1988-01-01

    The nervus terminalis (TN), a component of the olfactory system, is found in most vertebrates. The TN of some fishes and mammals contains neurons immunoreactive (ir) to gonadotropin-releasing hormone (LHRH), and to several other neuropeptides and neurotransmitter systems, but there is little information on TN chemistry in other vertebrate taxa. Using immunocytochemical techniques, we found LHRH-ir neurons in amphibian TNs. In anurans, but not in a urodele, the TN was also found to contain Phe-Met-Arg-Phe-NH2 (FMRFamide) immunoreactivity. LHRH-ir neurons of the TN and those of the septal-hypothalamic system are morphologically homogeneous and form a distinct anatomical continuum in amphibians. Based upon topographical and cytological criteria, we hypothesize that LHRH-ir systems in vertebrates might derive embryonically from the TN.

  8. Tail-extension following the termination codon is critical for release of the nascent chain from membrane-bound ribosomes in a reticulocyte lysate cell-free system.

    Science.gov (United States)

    Takahara, Michiyo; Sakaue, Haruka; Onishi, Yukiko; Yamagishi, Marifu; Kida, Yuichiro; Sakaguchi, Masao

    2013-01-11

    Nascent chain release from membrane-bound ribosomes by the termination codon was investigated using a cell-free translation system from rabbit supplemented with rough microsomal membrane vesicles. Chain release was extremely slow when mRNA ended with only the termination codon. Tail extension after the termination codon enhanced the release of the nascent chain. Release reached plateau levels with tail extension of 10 bases. This requirement was observed with all termination codons: TAA, TGA and TAG. Rapid release was also achieved by puromycin even in the absence of the extension. Efficient translation termination cannot be achieved in the presence of only a termination codon on the mRNA. Tail extension might be required for correct positioning of the termination codon in the ribosome and/or efficient recognition by release factors. Copyright © 2012. Published by Elsevier Inc.

  9. Octopus gonadotrophin-releasing hormone: a multifunctional peptide in the endocrine and nervous systems of the cephalopod.

    Science.gov (United States)

    Minakata, H; Shigeno, S; Kano, N; Haraguchi, S; Osugi, T; Tsutsui, K

    2009-03-01

    The optic gland, which is analogous to the anterior pituitary in the context of gonadal maturation, is found on the upper posterior edge of the optic tract of the octopus Octopus vulgaris. In mature octopus, the optic glands enlarge and secrete a gonadotrophic hormone. A peptide with structural features similar to that of vertebrate gonadotrophin-releasing hormone (GnRH) was isolated from the brain of octopus and was named oct-GnRH. Oct-GnRH showed luteinising hormone-releasing activity in the anterior pituitary cells of the Japanese quail Coturnix coturnix. Oct-GnRH immunoreactive signals were observed in the glandular cells of the mature optic gland. Oct-GnRH stimulated the synthesis and release of sex steroids from the ovary and testis, and elicited contractions of the oviduct. Oct-GnRH receptor was expressed in the gonads and accessory organs, such as the oviduct and oviducal gland. These results suggest that oct-GnRH induces the gonadal maturation and oviposition by regulating sex steroidogenesis and a series of egg-laying behaviours via the oct-GnRH receptor. The distribution and expression of oct-GnRH in the central and peripheral nervous systems suggest that oct-GnRH acts as a multifunctional modulatory factor in feeding, memory processing, sensory, movement and autonomic functions.

  10. SystemBurn: Principles of Design and Operation Release 3.0

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, Jonathan D [ORNL; Kuehn, Jeffery A [ORNL; Poole, Stephen W [ORNL; Hodson, Stephen W [ORNL; Glandon, Steven R [ORNL; Reister, David B [ORNL; Lewkow, Nicholas R [ORNL; Peek, Jacob T [ORNL

    2012-09-01

    As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

  11. Development of Ocular Delivery System for Glaucoma Therapy Using Natural Hydrogel as Film Forming Agent and Release Modifier.

    Science.gov (United States)

    Kulkarni, Giriraj T; Sethi, Nitin; Awasthi, Rajendra; Pawar, Vivek Kumar; Pahuja, Vineet

    2016-01-01

    Glaucoma is characterized by increased intraocular pressure, which results in damage to the optic nerve. The existing therapy with conventional eye drops is inefficient due to nasolachrymal drainage, resulting in a reduced corneal residence of the drug. The objective was to develop controlled-release ocular films of timolol maleate using natural hydrogel from Tamarindus indica seeds as a sustaining and film-forming agent, to overcome the problems associated with eye drops. The hydrogel was isolated using hot aqueous extraction followed by precipitation with ethanol. Six batches of ocular films were prepared and evaluated for drug content, weight variation, thickness, diameter and in vitro release profile. The ideal batch of the films was subjected to stability, pharmacodynamic and ocular safety studies. The yield of the hydrogel was 58.29%. The thickness of the ocular films was in the range of 0.17 to 0.25 mm and the weight of the films was found to increase with the increase in polymer content. The drug release from the films was found to be controlled over a period of 8 h. The films were found to be stable and were able to reduce the intraocular pressure for 24 h in a more efficient manner than the eye drops. The films were found to be practically non-irritating to the eye. It can be concluded that the hydrogel from tamarind seeds can be used as a film-forming and release-controlling agent for the development of an ocular drug delivery system for the effective therapy of glaucoma.

  12. Releases from the cooling water system in the Waste Tank Farm

    International Nuclear Information System (INIS)

    Perkins, W.C.; Lux, C.R.

    1991-01-01

    On September 12, 1991, a cooling-water header broke in the H-Area Waste Tank farm, at the Savannah River Site, releasing contaminated water down a storm sewer that drains to the creek. A copy of the Occurrence Report is attached. As part of the follow-up on this incident, the NPSR Section was asked by Waste Management Technology to perform a probabilistic analysis of the following cases: (1) A large break in the header combined with a large break in a cooling coil inside a waste tank. (2) A large break in the header combined with a leak in a cooling coil inside a waste tank. (3) A large break in the header combined with a very small leak in a cooling coil inside a waste tank. This report documents the results of the analysis of these cases

  13. Assessment of atmospherically-released radionuclides using the computerized radiological risk investigation system

    International Nuclear Information System (INIS)

    Nelson, C.B.; Sjoreen, A.L.; Miller, C.W.; Baes, C.F. III.

    1986-01-01

    For radionuclides, the standards are in terms of an annual dose, and the regulations require assurance that no member of the general public receives a dose in excess of that standard. Thus, spatial variations in the population around an emission source must be considered. Furthermore, for most chemical pollutants the standards are written in terms of an air concentration while for radionuclides other pathways of exposure, e.g., uptake of the airborne emissions by terrestrial food chains must also be considered. The remainder of this paper discusses the computer codes that make up the CRRIS and how they are used to perform an assessment of the health impacts on man of radionuclides released to the atmosphere

  14. Reporting consistently on CSR

    DEFF Research Database (Denmark)

    Thomsen, Christa; Nielsen, Anne Ellerup

    2006-01-01

    This chapter first outlines theory and literature on CSR and Stakeholder Relations focusing on the different perspectives and the contextual and dynamic character of the CSR concept. CSR reporting challenges are discussed and a model of analysis is proposed. Next, our paper presents the results...... of a case study showing that companies use different and not necessarily consistent strategies for reporting on CSR. Finally, the implications for managerial practice are discussed. The chapter concludes by highlighting the value and awareness of the discourse and the discourse types adopted...... in the reporting material. By implementing consistent discourse strategies that interact according to a well-defined pattern or order, it is possible to communicate a strong social commitment on the one hand, and to take into consideration the expectations of the shareholders and the other stakeholders...

  15. Geometrically Consistent Mesh Modification

    KAUST Repository

    Bonito, A.

    2010-01-01

    A new paradigm of adaptivity is to execute refinement, coarsening, and smoothing of meshes on manifolds with incomplete information about their geometry and yet preserve position and curvature accuracy. We refer to this collectively as geometrically consistent (GC) mesh modification. We discuss the concept of discrete GC, show the failure of naive approaches, and propose and analyze a simple algorithm that is GC and accuracy preserving. © 2010 Society for Industrial and Applied Mathematics.

  16. Informal uncertainty analysis (GLUE of continuous flow simulation in a hybrid sewer system with infiltration inflow – consistency of containment ratios in calibration and validation?

    Directory of Open Access Journals (Sweden)

    A. Breinholt

    2013-10-01

    Full Text Available Monitoring of flows in sewer systems is increasingly applied to calibrate urban drainage models used for long-term simulation. However, most often models are calibrated without considering the uncertainties. The generalized likelihood uncertainty estimation (GLUE methodology is here applied to assess parameter and flow simulation uncertainty using a simplified lumped sewer model that accounts for three separate flow contributions: wastewater, fast runoff from paved areas, and slow infiltrating water from permeable areas. Recently GLUE methodology has been critisised for generating prediction limits without statistical coherence and consistency and for the subjectivity in the choice of a threshold value to distinguish "behavioural" from "non-behavioural" parameter sets. In this paper we examine how well the GLUE methodology performs when the behavioural parameter sets deduced from a calibration period are applied to generate prediction bounds in validation periods. By retaining an increasing number of parameter sets we aim at obtaining consistency between the GLUE generated 90% prediction limits and the actual containment ratio (CR in calibration. Due to the large uncertainties related to spatio-temporal rain variability during heavy convective rain events, flow measurement errors, possible model deficiencies as well as epistemic uncertainties, it was not possible to obtain an overall CR of more than 80%. However, the GLUE generated prediction limits still proved rather consistent, since the overall CRs obtained in calibration corresponded well with the overall CRs obtained in validation periods for all proportions of retained parameter sets evaluated. When focusing on wet and dry weather periods separately, some inconsistencies were however found between calibration and validation and we address here some of the reasons why we should not expect the coverage of the prediction limits to be identical in calibration and validation periods in real

  17. Novel drug delivery systems for releasing growth factors to the CNS: focus on Alzheimer's and Parkinson's diseases.

    Science.gov (United States)

    Herran, E; Igartua, M; Pedraz, J L; Hernandez, R M

    2014-01-01

    Alzheimer's disease (AD) and Parkinson's disease (PD) represent the most common neurodegenerative disorders and affect more than 35 million people. Due to the limited effectiveness of available treatments in halting the neurodegenerative process, new therapies, such therapies based on growth factors (GFs), have been investigated. Nevertheless, the efficacies of these new treatments depend not only on the application of neurotrophins but also on the approaches used to deliver these proteins such that they can reach the brain. This review summarises the most widely used drug delivery systems (DDSs) for releasing GFs as possible treatments for AD and PD.

  18. Sympathetic nervous activity and renal and systemic hemodynamics in cirrhosis: plasma norepinephrine concentration, hepatic extraction, and renal release

    DEFF Research Database (Denmark)

    Ring-Larsen, H; Hesse, B; Henriksen, Jens Henrik Sahl

    1982-01-01

    as previously reported in healthy controls. The right kidney released NE into the systemic circulation. Renal venous plasma NE exceeded arterial concentration by 34% (p less than 0.01). It is concluded that sympathetic nervous activity is enhanced in patients with cirrhosis, and that this hyperactivity may...... in patients than controls (82 vs. 95 mm Hg, p less than 0.05) but did not change during the tilt. Plasma norepinephrine (NE) concentration was significantly higher in another eight patients with cirrhosis than in eight healthy controls (mean: 0.45 vs. 0.21 ng per ml in recumbency, p less than 0.02). Following...

  19. Is litter decomposition 'primed' by primary producer-release of labile carbon in terrestrial and aquatic experimental systems?

    Science.gov (United States)

    Soares, A. Margarida P. M.; Kritzberg, Emma S.; Rousk, Johannes

    2015-04-01

    It is possible that recalcitrant organic matter (ROM) can be 'activated' by inputs of labile organic matter (LOM) through the priming effect (PE). Investigating the PE is of major importance to fully understand the microbial use of ROM and its role on carbon (C) and nutrient cycling in both aquatic and terrestrial ecosystems. In aquatic ecosystems it is thought that the PE is triggered by periphytic algae release of LOM. Analogously, in terrestrial systems it is hypothesized that the LOM released in plant rhizospheres, or from the green crusts on the surface of agricultural soils, stimulate the activity and growth of ROM decomposers. Most previous studies on PE have utilised pulse additions of single substrates at high concentrations. However, to achieve an assessment of the true importance of the PE, it is important to simulate a realistic delivery of LOM. We investigated, in a series of 2-week laboratory experiments, how primary producer (PP)-release of LOM influence litter degradation in terrestrial and aquatic experimental systems. We used soil (terrestrial) and pond water (aquatic) microbial communities to which litter was added under light and dark conditions. In addition, glucose was added at PP delivery rates in dark treatments to test if the putative PE in light systems could be reproduced. We observed an initial peak of bacterial growth rate followed by an overall decrease over time with no treatment differences. In light treatments, periphytic algae growth and increased fungal production was stimulated when bacterial growth declined. In contrast, both fungal growth and algal production were negligible in dark treatments. This reveals a direct positive influence of photosynthesis on fungal growth. To investigate if PP LOM supplements, and the associated fungal growth, translate into a modulated litter decomposition, we are using stable isotopes to track the use of litter and algal-derived carbon by determining the δ13C in produced CO2. Fungi and bacteria

  20. Preparation of starch nanoparticles in a water-in-ionic liquid microemulsion system and their drug loading and releasing properties.

    Science.gov (United States)

    Zhou, Gang; Luo, Zhigang; Fu, Xiong

    2014-08-13

    An ionic liquid microemulsion consisting of 1-butyl-3-methylimidazolium hexafluorophosphate ([Bmim]PF₆), surfactant TX-100, 1-butanol, and water was prepared. The water-in-[Bmim]PF₆ (W/IL), bicontinuous, and [Bmim]PF₆-in-water (IL/W) microregions of the microemulsion were identified by conductivity measurements. Starch nanoparticles with a mean diameter of 91.4 nm were synthesized with epichlorohydrin as cross-linker through W/IL microemulsion cross-linking reaction at 50 °C for 4 h. Fourier transform infrared spectroscopy (FTIR) data demonstrated the formation of cross-linking bonds in starch molecules. Scanning electron microscopy (SEM) revealed that starch nanoparticles were spherical and that some particles showed aggregation formation. Furthermore, drug loading and releasing properties of starch nanoparticles were investigated with mitoxantrone hydrochloride as a drug model. This work provides an efficient and environmentally friendly approach for the preparation of starch nanoparticles, which is beneficial to their further application.

  1. Experimental Investigation In The PANDA Facility Of The Impact Of A Hydrogen Release On Passive Containment Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Auban, O.; Paladino, D.; Candreia, P.; Huggenberger, M.; Strassberger, H.J

    2003-03-01

    The large-scale, thermal-hydraulics PANDA facility has been used in the past for investigating passive decay-heat removal systems and related containment phenomena for a number of next-generation Light Water Reactors. Passive Containment Condenser (PCC) systems operate by transferring heat via steam condensation from inside the containment to outside, and serve to mitigate pressure build-up in the event of steam discharge from the primary circuit. Five new integral tests have recently been performed in the context of the 5th European Framework Program project TEMPEST. One main objective was to assess the influence of a light gas (hydrogen) on the performance of the Passive Containment Cooling System (PCCS). Hydrogen release in the case of a severe accident is simulated in PANDA by injecting helium with steam into the Drywell. In addition, the impact of a new accident-mitigating design feature, the Drywell Gas Re-Circulation System (DGRS), on the long-term containment behaviour was tested. Another important objective was also to provide relevant data for the validation of modern 3/4 mainly Computational Fluid Dynamics (CFD) 3/4 codes. The paper reports main observations from two of these new integral tests in which standard PANDA instrumentation has provided important data concerning system response when helium is released in the course of the transient. The results show that some important stratification phenomena have occurred, as a result of the buoyant flow generated by the helium injection. The resulting temperature and concentration measurements show how helium is being distributed in the Drywell (DW) volume during the helium injection phase, and how helium is retained or vented out of these vessels once the injection stops. The paper includes some discussion concerning the influence of gas mixing and stratification and the effect of the DGRS on PCC performance and system pressure build-up. (author)

  2. Polyelectrolyte Complex Based Interfacial Drug Delivery System with Controlled Loading and Improved Release Performance for Bone Therapeutics

    Directory of Open Access Journals (Sweden)

    David Vehlow

    2016-03-01

    Full Text Available An improved interfacial drug delivery system (DDS based on polyelectrolyte complex (PEC coatings with controlled drug loading and improved release performance was elaborated. The cationic homopolypeptide poly(l-lysine (PLL was complexed with a mixture of two cellulose sulfates (CS of low and high degree of substitution, so that the CS and PLL solution have around equal molar charged units. As drugs the antibiotic rifampicin (RIF and the bisphosphonate risedronate (RIS were integrated. As an important advantage over previous PEC systems this one can be centrifuged, the supernatant discarded, the dense pellet phase (coacervate separated, and again redispersed in fresh water phase. This behavior has three benefits: (i Access to the loading capacity of the drug, since the concentration of the free drug can be measured by spectroscopy; (ii lower initial burst and higher residual amount of drug due to removal of unbound drug and (iii complete adhesive stability due to the removal of polyelectrolytes (PEL excess component. It was found that the pH value and ionic strength strongly affected drug content and release of RIS and RIF. At the clinically relevant implant material (Ti40Nb similar PEC adhesive and drug release properties compared to the model substrate were found. Unloaded PEC coatings at Ti40Nb showed a similar number and morphology of above cultivated human mesenchymal stem cells (hMSC compared to uncoated Ti40Nb and resulted in considerable production of bone mineral. RIS loaded PEC coatings showed similar effects after 24 h but resulted in reduced number and unhealthy appearance of hMSC after 48 h due to cell toxicity of RIS.

  3. Is cosmology consistent?

    International Nuclear Information System (INIS)

    Wang Xiaomin; Tegmark, Max; Zaldarriaga, Matias

    2002-01-01

    We perform a detailed analysis of the latest cosmic microwave background (CMB) measurements (including BOOMERaNG, DASI, Maxima and CBI), both alone and jointly with other cosmological data sets involving, e.g., galaxy clustering and the Lyman Alpha Forest. We first address the question of whether the CMB data are internally consistent once calibration and beam uncertainties are taken into account, performing a series of statistical tests. With a few minor caveats, our answer is yes, and we compress all data into a single set of 24 bandpowers with associated covariance matrix and window functions. We then compute joint constraints on the 11 parameters of the 'standard' adiabatic inflationary cosmological model. Our best fit model passes a series of physical consistency checks and agrees with essentially all currently available cosmological data. In addition to sharp constraints on the cosmic matter budget in good agreement with those of the BOOMERaNG, DASI and Maxima teams, we obtain a heaviest neutrino mass range 0.04-4.2 eV and the sharpest constraints to date on gravity waves which (together with preference for a slight red-tilt) favor 'small-field' inflation models

  4. Consistent Quantum Theory

    Science.gov (United States)

    Griffiths, Robert B.

    2001-11-01

    Quantum mechanics is one of the most fundamental yet difficult subjects in physics. Nonrelativistic quantum theory is presented here in a clear and systematic fashion, integrating Born's probabilistic interpretation with Schrödinger dynamics. Basic quantum principles are illustrated with simple examples requiring no mathematics beyond linear algebra and elementary probability theory. The quantum measurement process is consistently analyzed using fundamental quantum principles without referring to measurement. These same principles are used to resolve several of the paradoxes that have long perplexed physicists, including the double slit and Schrödinger's cat. The consistent histories formalism used here was first introduced by the author, and extended by M. Gell-Mann, J. Hartle and R. Omnès. Essential for researchers yet accessible to advanced undergraduate students in physics, chemistry, mathematics, and computer science, this book is supplementary to standard textbooks. It will also be of interest to physicists and philosophers working on the foundations of quantum mechanics. Comprehensive account Written by one of the main figures in the field Paperback edition of successful work on philosophy of quantum mechanics

  5. Soluble microbial products (SMPs release in activated sludge systems: a review

    Directory of Open Access Journals (Sweden)

    Azami Hamed

    2012-12-01

    Full Text Available Abstract This review discusses the characterization, production and implications of soluble microbial products (SMPs in biological wastewater treatment. The precise definition of SMPs is open to talk about, but is currently regarded as “the pool of organic compounds that are released into solution from substrate metabolism and biomass decay”'. Some of the SMPs have been identified as humic acids, polysaccharides, proteins, amino acids, antibiotics, extracellular enzymes and structural components of cells and products of energy metabolism. They adversely affect the kinetic activity, flocculating and settling properties of sludge. This review outlines some important findings with regard to biodegradability and treatability of SMPs and also the effect of process parameters on their production. As SMPs are produced during biological treatment process, their trace amounts normally remain in the effluent that defines the highest COD removal efficiency. Their presence in effluent represents a high potential risk of toxic by-product formation during chlorine disinfection. Studies have indicated that among all wastewater post-treatment processes, the adsorption by granular activated carbon combined with biologically induced degradation is the most effective method for removal of SMPs. However, it may be concludes that the knowledge regarding SMPs is still under progress and more work is required to fully understand their contribution to the treatment process.

  6. Soluble Microbial Products (SMPs Release in Activated Sludge Systems: a Review

    Directory of Open Access Journals (Sweden)

    Hamed Azami

    2012-12-01

    Full Text Available This review discusses the characterization, production and implications of soluble microbial products (SMPs in biological wastewater treatment. The precise definition of SMPs is open to talk about, but is currently regarded as “the pool of organic compounds that are released into solution from substrate metabolism and biomass decay”'.Some of the SMPs have been identified as humic acids, olysaccharides, proteins, amino acids, antibiotics,extracellular enzymes and structural components of cells and products of energy metabolism. They adversely affect the kinetic activity, flocculating and settling properties of sludge. This review outlines some important findings with regard to biodegradability and treatability of SMPs and also the effect of process parameters on their production.As SMPs are produced during biological treatment process, their trace amounts normally remain in the effluent that defines the highest COD removal efficiency. Their presence in effluent represents a high potential risk of toxic by-product formation during chlorine disinfection. Studies have indicated that among all wastewaterpost-treatment processes, the adsorption by granular activated carbon combined with biologically induced degradation is the most effective method for removal of SMPs. However, it may be concludes that the knowledge regarding SMPs is still under progress and more work is required to fully understand their contribution to the treatment process.

  7. Setup of Extruded Cementitious Hollow Tubes as Containing/Releasing Devices in Self-Healing Systems

    Directory of Open Access Journals (Sweden)

    Alessandra Formia

    2015-04-01

    Full Text Available The aim of this research is to produce self-healing cementitious composites based on the use of cylindrical capsules containing a repairing agent. Cementitious hollow tubes (CHT having two different internal diameters (of 2 mm and 7.5 mm were produced by extrusion and used as containers and releasing devices for cement paste/mortar healing agents. Based on the results of preliminary mechanical tests, sodium silicate was selected as the healing agent. The morphological features of several mix designs used to manufacture the extruded hollow tubes, as well as the coatings applied to increase the durability of both core and shell materials are discussed. Three-point bending tests were performed on samples produced with the addition of the above-mentioned cementitious hollow tubes to verify the self-healing effectiveness of the proposed solution. Promising results were achieved, in particular when tubes with a bigger diameter were used. In this case, a substantial strength and stiffness recovery was observed, even in specimens presenting large cracks (>1 mm. The method is inexpensive and simple to scale up; however, further research is needed in view of a final optimization.

  8. Release of hydrogen sulfide in a sewer system under intermittent flow conditions

    DEFF Research Database (Denmark)

    Matias, Natércia; Matos, Rita Ventura; Ferreira, Filipa

    2017-01-01

    The presence and fate of hydrogen sulfide in wastewater systems were studied in two stretches of an intercepting sewer system located in a coastal village, in Portugal. A range of hydraulic parameters were obtained and liquid and gas phase measurements were carried out, both continuously and thro......The presence and fate of hydrogen sulfide in wastewater systems were studied in two stretches of an intercepting sewer system located in a coastal village, in Portugal. A range of hydraulic parameters were obtained and liquid and gas phase measurements were carried out, both continuously...... authors’ publications addressing relatively small pipes and moderate water flows....

  9. Primary system fission product release and transport: A state-of-the-art report to the committee on the safety of nuclear installations

    International Nuclear Information System (INIS)

    Wright, A.L.

    1994-06-01

    This report presents a summary of the status of research activities associated with fission product behavior (release and transport) under severe accident conditions within the primary systems of water-moderated and water-cooled nuclear reactors. For each of the areas of fission product release and fission product transport, the report summarizes relevant information on important phenomena, major experiments performed, relevant computer models and codes, comparisons of computer code calculations with experimental results, and general conclusions on the overall state of the art. Finally, the report provides an assessment of the overall importance and knowledge of primary system release and transport phenomena and presents major conclusions on the state of the art

  10. Primary system fission product release and transport. A state-of-the-art report to the committee on the safety of nuclear installations

    International Nuclear Information System (INIS)

    Wright, A.L.

    1994-06-01

    This report presents a summary of the status of research activities associated with fission product behavior (release and transport) under severe accident conditions within the primary systems of water-moderated and water-cooled nuclear reactors. For each of the areas of fission product release and fission product transport, the report summarizes relevant information on important phenomena, major experiments performed, relevant computer models and codes, comparisons of computer code calculations with experimental results, and general conclusions on the overall state of the art. Finally, the report provides an assessment of the overall importance and knowledge of primary system release and transport phenomena and presents major conclusions on the state of the art

  11. Primary system fission product release and transport: A state-of-the-art report to the committee on the safety of nuclear installations

    Energy Technology Data Exchange (ETDEWEB)

    Wright, A.L. [Oak Ridge National Lab., TN (United States)

    1994-06-01

    This report presents a summary of the status of research activities associated with fission product behavior (release and transport) under severe accident conditions within the primary systems of water-moderated and water-cooled nuclear reactors. For each of the areas of fission product release and fission product transport, the report summarizes relevant information on important phenomena, major experiments performed, relevant computer models and codes, comparisons of computer code calculations with experimental results, and general conclusions on the overall state of the art. Finally, the report provides an assessment of the overall importance and knowledge of primary system release and transport phenomena and presents major conclusions on the state of the art.

  12. Risk assessment and experimental design in the development of a prolonged release drug delivery system with paliperidone.

    Science.gov (United States)

    Iurian, Sonia; Turdean, Luana; Tomuta, Ioan

    2017-01-01

    This study focuses on the development of a drug product based on a risk assessment-based approach, within the quality by design paradigm. A prolonged release system was proposed for paliperidone (Pal) delivery, containing Kollidon ® SR as an insoluble matrix agent and hydroxypropyl cellulose, hydroxypropyl methylcellulose (HPMC), or sodium carboxymethyl cellulose as a hydrophilic polymer. The experimental part was preceded by the identification of potential sources of variability through Ishikawa diagrams, and failure mode and effects analysis was used to deliver the critical process parameters that were further optimized by design of experiments. A D-optimal design was used to investigate the effects of Kollidon SR ratio ( X 1 ), the type of hydrophilic polymer ( X 2 ), and the percentage of hydrophilic polymer ( X 3 ) on the percentages of dissolved Pal over 24 h ( Y 1 - Y 9 ). Effects expressed as regression coefficients and response surfaces were generated, along with a design space for the preparation of a target formulation in an experimental area with low error risk. The optimal formulation contained 27.62% Kollidon SR and 8.73% HPMC and achieved the prolonged release of Pal, with low burst effect, at ratios that were very close to the ones predicted by the model. Thus, the parameters with the highest impact on the final product quality were studied, and safe ranges were established for their variations. Finally, a risk mitigation and control strategy was proposed to assure the quality of the system, by constant process monitoring.

  13. Tracking of the micro-structural changes of levonorgestrel-releasing intrauterine system by positron annihilation lifetime spectroscopy.

    Science.gov (United States)

    Patai, Kálmán; Szente, Virág; Süvegh, Károly; Zelkó, Romána

    2010-12-01

    The morphology and the micro-structural changes of levonorgestrel-releasing intrauterine systems (IUSs) were studied in relation to the duration of their application. The morphology of the removed IUSs was examined without pre-treatment by scanning electron microscopy. The micro-structural changes of the different layers of IUSs were tracked by positron annihilation lifetime spectroscopy. Besides the previously found incrustation formation, the free volume of the hormone containing reservoir was remarkably increased after 3 years of application, thus increasing the real volume of the core of the systems. Although the free volume of the membrane encasing the core was not significantly changed in the course of the application, as a result of the core expansion, microcracks could be formed on the membrane surface. Along these cracks, deposits of different compositions can be formed, causing inflammatory complications and influencing the drug release of IUSs. Stability tests in combination with micro-structural screening of such IUSs could be required during their development phase to avoid the undesired side effects. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  14. Heat Release Property and Fire Performance of the Nomex/Cotton Blend Fabric Treated with a Nonformaldehyde Organophosphorus System

    Directory of Open Access Journals (Sweden)

    Charles Q. Yang

    2016-09-01

    Full Text Available Blending Nomex® with cotton improves its affordability and serviceability. Because cotton is a highly flammable fiber, Nomex®/cotton blend fabrics containing more than 20% cotton require flame-retardant treatment. In this research, combination of a hydroxyl functional organophosphorus oligmer (HFPO and 1,2,3,4-butanetetracarboxylic acid (BTCA was used for flame retardant finishing of the 65/35 Nomex®/cotton blend woven fabric. The system contains HFPO as a flame retardant, BTCA as a bonding agent, and triethenolamine (TEA as a reactive additive used to enhance the performance of HFPO/BTCA. Addition of TEA improves the hydrolysis resistance of the HFPO/BTCA crosslinked polymeric network on the blend fabric. Additionally, TEA enhances HFPO’s flame retardant performance by reducing formation of calcium salts and also by providing synergistic nitrogen to the treated blend fabric. The Nomex®/cotton blend fabric treated with the HFPO/BTCA/TEA system shows high flame resistance and high laundering durability at a relatively low HFPO concentration of 8% (w/w. The heat release properties of the treated Nomex®/cotton blend fabric were measured using microscale combustion calorimetry. The functions of BTCA; HFPO and TEA on the Nomex®/cotton blend fabric were elucidated based on the heat release properties, char formation, and fire performance of the treated blend fabric.

  15. Gut does not contribute to systemic ammonia release in humans without portosystemic shunting

    NARCIS (Netherlands)

    van de Poll, Marcel C. G.; Ligthart-Melis, Gerdien C.; Damink, Steven W. M. Olde; van Leeuwen, Paul A. M.; Beets-Tan, Regina G. H.; Deutz, Nicolaas E. P.; Wigmore, Stephen J.; Soeters, Peter B.; Dejong, Cornelis H. C.

    2008-01-01

    The gut is classically seen as the main source of circulating ammonia. However, the contribution of the intestines to systemic ammonia production may be limited by hepatic extraction of portal-derived ammonia. Recent data suggest that the kidney may be more important than the gut for systemic

  16. 75 FR 58374 - 2010 Release of CADDIS (Causal Analysis/Diagnosis Decision Information System)

    Science.gov (United States)

    2010-09-24

    ... Decision Information System) AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of public... 2010 version of the Causal Analysis/Diagnosis Decision Information System (CADDIS). This Web site was developed to help scientists find, develop, organize, and use environmental information to improve causal...

  17. Mechanisms and interaction phenomena influencing releases in low- and medium-level waste disposal systems

    International Nuclear Information System (INIS)

    Brodersen, K.; Nilsson, K.

    1990-11-01

    The report covers work done 1986-1990 at Risoe National Laboratory as part of the third EC Research Programme on Radioactive Waste Management. Waste product characterization: Leaching and volume stability of cemented ion-exchange resins. Wet/dry cycling was found to be an important degradation mechanism. Hygroscopic properties of cemented and bituminized radioactive waste. Water uptake from the air can be an important release mechanism when waste containing soluble salts are disposed of by shallow land burial. Water uptake and swelling of bituminized waste including studies on water migration in bitumen membranes and measurements of swelling pressures. Ageing of bituminized products was demonstrated to result in increasing stiffness of the materials. Nickel ferrocyanide in precipitation sludge was found to be unstable in contact with concrete. Barrier material properties: The influence of the pore structure in concrete on the hydraulic or diffusive transport of water and ions through concrete barriers was investigated. The main parameter is the water/cement ratio. A theoretical interpretation is given. Healing of cracks in concrete barriers by precipitation of calcium carbonate was demonstrated experimentally and described by a simplified model. Transport of components between two thin plates of cement paste with different composition stored together in water was found to take place at a low rate. The structure of degraded cement paste was studied using SANS (small angle neutron scattering). Interaction phenomena: - Integral experiments with migration of radioisotopes from cemented waste through barriers made from kaolin, chalk or concrete were made under different external conditions. The results can be used for model validation and some preliminary work was done. (author) 16 tabs., 51 ills., 25 refs

  18. The Bulgarian Emergency Response System for dose assessment in the early stage of accidental releases to the atmosphere

    International Nuclear Information System (INIS)

    Syrakov, D.; Veleva, B.; Prodanova, M.; Popova, T.; Kolarova, M.

    2009-01-01

    The Bulgarian Emergency Response System (BERS) is being developed in the Bulgarian National Institute of Meteorology and Hydrology since 1994. BERS is based on numerical weather forecast meteorological information and a numerical long-range dispersion model accounting for the transport, dispersion, chemical and radioactive transformations of pollutants. In the present paper, the further development of this system for a mixture of radioactive gaseous and aerosol pollutants is described. The basic module for the BERS, the numerical dispersion model EMAP, is upgraded with a 'dose calculation block'. Two scenarios for hypothetical accidental atmospheric releases from two NPPs, one in Western, and the other in Eastern Europe, are numerically simulated. The effective doses from external irradiation, from air submersion and ground shinning, effective dose from inhalation and absorbed dose by thyroid gland formed by 37 different radionuclides, significant for the early stage of a nuclear accident, are calculated as dose fields for both case studies and discussed

  19. Sustained, Controlled and Stimuli-Responsive Drug Release Systems Based on Nanoporous Anodic Alumina with Layer-by-Layer Polyelectrolyte

    Science.gov (United States)

    Porta-i-Batalla, Maria; Eckstein, Chris; Xifré-Pérez, Elisabet; Formentín, Pilar; Ferré-Borrull, J.; Marsal, Lluis F.

    2016-08-01

    Controlled drug delivery systems are an encouraging solution to some drug disadvantages such as reduced solubility, deprived biodistribution, tissue damage, fast breakdown of the drug, cytotoxicity, or side effects. Self-ordered nanoporous anodic alumina is an auspicious material for drug delivery due to its biocompatibility, stability, and controllable pore geometry. Its use in drug delivery applications has been explored in several fields, including therapeutic devices for bone and dental tissue engineering, coronary stent implants, and carriers for transplanted cells. In this work, we have created and analyzed a stimuli-responsive drug delivery system based on layer-by-layer pH-responsive polyelectrolyte and nanoporous anodic alumina. The results demonstrate that it is possible to control the drug release using a polyelectrolyte multilayer coating that will act as a gate.

  20. A demonstration of the applicability of implementing the enhanced Remedial Action Priority System (RAPS) for environmental releases

    Energy Technology Data Exchange (ETDEWEB)

    Whelan, G.; Droppo, J.G. Jr.; Strenge, D.L.; Walter, M.B.; Buck, J.W.

    1989-12-01

    The Remedial Action Priority System (RAPS) and the Multimedia Environmental Pollutant Assessment System (MEPAS) were developed to prioritize problems associated with potential releases of hazardous chemical and radioactive materials in a scientific and objective manner based on limited site information. This report documents the model testing efforts of the RAPS/MEPAS methodology for the atmospheric, surface water, groundwater, and exposure components. Comparisons are given of model outputs with measured data at three sites: the US Department of Energy's Mound facility in Ohio and Hanford facility in Washington, and a chromium-cadmium plating site in New York. The results show that the simulated magnitudes, spacial and temporal trends, and distributions of contaminants corresponded well with the measured data. 25 refs., 86 figs., 26 tabs.

  1. Theoretical modeling of large molecular systems. Advances in the local self consistent field method for mixed quantum mechanics/molecular mechanics calculations.

    Science.gov (United States)

    Monari, Antonio; Rivail, Jean-Louis; Assfeld, Xavier

    2013-02-19

    Molecular mechanics methods can efficiently compute the macroscopic properties of a large molecular system but cannot represent the electronic changes that occur during a chemical reaction or an electronic transition. Quantum mechanical methods can accurately simulate these processes, but they require considerably greater computational resources. Because electronic changes typically occur in a limited part of the system, such as the solute in a molecular solution or the substrate within the active site of enzymatic reactions, researchers can limit the quantum computation to this part of the system. Researchers take into account the influence of the surroundings by embedding this quantum computation into a calculation of the whole system described at the molecular mechanical level, a strategy known as the mixed quantum mechanics/molecular mechanics (QM/MM) approach. The accuracy of this embedding varies according to the types of interactions included, whether they are purely mechanical or classically electrostatic. This embedding can also introduce the induced polarization of the surroundings. The difficulty in QM/MM calculations comes from the splitting of the system into two parts, which requires severing the chemical bonds that link the quantum mechanical subsystem to the classical subsystem. Typically, researchers replace the quantoclassical atoms, those at the boundary between the subsystems, with a monovalent link atom. For example, researchers might add a hydrogen atom when a C-C bond is cut. This Account describes another approach, the Local Self Consistent Field (LSCF), which was developed in our laboratory. LSCF links the quantum mechanical portion of the molecule to the classical portion using a strictly localized bond orbital extracted from a small model molecule for each bond. In this scenario, the quantoclassical atom has an apparent nuclear charge of +1. To achieve correct bond lengths and force constants, we must take into account the inner shell of

  2. Microspheres prepared with biodegradable PHBV and PLA polymers as prolonged-release system for ibuprofen: in vitro drug release and in vivo evaluation

    Directory of Open Access Journals (Sweden)

    Giovana Carolina Bazzo

    2012-12-01

    Full Text Available In this study, poly(hydroxybutyrate-co-hydroxyvalerate (PHBV and poly(l-lactide (PLA microspheres containing ibuprofen were prepared with the aim of prolonging the drug release. The oil-in-water (O/W emulsion solvent evaporation technique was used, varying the polymer ratio. All formulations provided spherical particles with drug crystals on the surface and a porous and rough polymeric matrix when PHBV was used and smooth external surface when prepared with PLA. The in vitro dissolution profiles show that the formulation containing PHBV/PLA at the proportion of 30/70 presented the best results in terms of prolonging the ibuprofen release. The analysis of the concentration of ibuprofen in the blood of rats showed that maximum levels were achieved at between one and two hours after administration of the immediate-release form (pure drug, while the prolonged microspheres led to a small amount of the drug being released within the first two hours and reached the maximum level after six hours of administration. It was concluded that it is possible to prolong the release of ibuprofen through its incorporation into PHBV/PLA microspheres.No presente estudo foram preparadas microesferas de poli(hidroxibutirato-co-hidroxivalerato (PHBV e poli(ácido láctico (PLA com o objetivo de prolongar a liberação do ibuprofeno, utilizado como fármaco modelo. Empregou-se o método de emulsificação e evaporação do solvente óleo em água (O/A, variando-se a proporção entre os polímeros. Todas as formulações originaram partículas esféricas com cristais de fármaco aderidos à superfície externa. As microesferas apresentaram superfície rugosa e porosa, quando o PHBV foi utilizado, e superfície externa lisa, quando preparadas com o PLA. Os perfis de dissolução in vitro evidenciaram que a formulação que continha PHBV/PLA na proporção de 30/70 apresentou melhores resultados para prolongar a liberação do ibuprofeno. Através da análise da concentra

  3. Decomposition and nutrient release in leaves of Atlantic Rainforest tree species used in agroforestry systems

    NARCIS (Netherlands)

    Duarte, E.M.G.; Cardoso, I.M.; Stijnen, T.; Mendonça, M.A.F.C.; Coelho, M.S.; Cantarutti, R.B.; Kuyper, T.W.; Villani, E.M.A.; Mendonça, E.S.

    2013-01-01

    Aiming to support the use of native species from the Atlantic Rainforest in local agroforestry systems, we analysed chemical and biochemical components related to leaf decomposition of Inga subnuda, Senna macranthera, Erythrina verna, Luehea grandiflora, Zeyheria tuberculosa, Aegiphila sellowiana,

  4. 78 FR 56541 - Concept Release on Risk Controls and System Safeguards for Automated Trading Environments

    Science.gov (United States)

    2013-09-12

    ... for three hours due to malfunctions in quote dissemination systems and potential connectivity issues... (``TAC''); the Futures Industry Association's (``FIA'') Principal Traders Group and Market Access Working Group; the International Organization of Securities Commissions (``IOSCO''); the European Securities and...

  5. Biophysical elucidation of the mechanism of enhanced drug release and topical delivery from polymeric film-forming systems.

    Science.gov (United States)

    Garvie-Cook, Hazel; Frederiksen, Kit; Petersson, Karsten; Guy, Richard H; Gordeev, Sergey N

    2015-08-28

    The effect of incorporating the lipidic medium-chain triglyceride (MCT) into polymeric film-forming systems (FFS) for topical drug delivery has been evaluated. First, the in vitro release of betamethasone-17-valerate (BMV), a representative dermatological drug, was determined from FFS comprising either hydrophobic polyacrylate co-polymers, or hydrophilic hydroxypropyl cellulose, with and without MCT. Release was enhanced from both polymers in the presence of MCT. Atomic force microscopy imaging and nanoindentation of FFS with MCT revealed two-phase structured films with softer inclusions (0.5 to 4μm in diameter) surrounded by a more rigid structure. Chemical mapping with Raman micro-spectroscopy showed that MCT was primarily confined to the inclusions within the polymer, which predominated in the surrounding film. BMV was distributed throughout the film but was more concentrated outside the inclusions. Furthermore, while BMV dissolved better into the hydrophobic films, it was more soluble in the MCT inclusions in hydrophilic films, suggesting its increased availability for diffusion from these softer regions of the polymer and explaining the release enhancement observed. Second, ex vivo skin penetration studies clearly revealed that uptake of BMV was higher from hydrophobic FFS than that from the more hydrophilic polymer due, at least in part, to the superior anti-nucleation efficiency of the former. Drug was quickly taken up into the SC from which it then diffused continuously over a sustained period into the lower, viable skin layers. In the presence of MCT, the overall uptake of BMV was increased and provides the basis for further optimisation of FFS as simple, convenient and sustained formulations for topical therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Model studies on the release of aroma compounds from structured and nonstructured oil systems using proton-transfer reaction mass spectrometry.

    Science.gov (United States)

    Landy, Pascale; Pollien, Philippe; Rytz, Andreas; Leser, Martin E; Sagalowicz, Laurent; Blank, Imre; Spadone, Jean-Claude

    2007-03-07

    Relative retention, volatility, and temporal release of volatile compounds taken from aldehyde, ester, and alcohol chemical classes were studied at 70 degrees C in model systems using equilibrium static headspace analysis and real time dynamic headspace analysis. These systems were medium-chain triglycerides (MCT), sunflower oil, and two structured systems, i.e., water-in-oil emulsion and L2 phase (water-in-oil microemulsion). Hydrophilic domains of the emulsion type media retained specifically the hydrophilic compounds and alcohols. Four kinetic parameters characterizing the concentration- and time-dependent releases were extracted from the aroma release curves. Most of the kinetic parameter values were higher in structured systems than in oils particularly when using MCT. The oil nature was found to better control the dynamic release profiles than the system structures. The release parameters were well-related (i) to the volatile hydrophobicity as a function of the oil used and (ii) to the retention data in the specific case of the L2 phase due to a specific release behavior of alcohols.

  7. Consistency Anchor Formalization and Correctness Proofs

    OpenAIRE

    Miguel, Correia; Bessani, Alysson

    2014-01-01

    This is report contains the formal proofs for the techniques for increasing the consistency of cloud storage as presented in "Bessani et al. SCFS: A Cloud-backed File System. Proc. of the 2014 USENIX Annual Technical Conference. June 2014." The consistency anchor technique allows one to increase the consistency provided by eventually consistent cloud storage services like Amazon S3. This technique has been used in the SCFS (Shared Cloud File System) cloud-backed file system for solving rea...

  8. In vitro efficacy and release study with anti-inflammatory drugs incorporated in adhesive transdermal drug delivery systems.

    Science.gov (United States)

    Meyer, Stefanie; Peters, Nils; Mann, Tobias; Wolber, Rainer; Pörtner, Ralf; Nierle, Jens

    2014-04-01

    The topical application of two different anti-inflammatory extracts incorporated in adhesive transdermal drug delivery systems (TDDSs) was investigated. Therefore, anti-inflammatory properties and percutaneous absorption behavior of adhesive TDDSs were characterized in vitro conducting experiments with a dermatologically relevant human skin model. Anti-inflammatory efficacy against UV irradiation of both TDDSs was determined in vitro with EpiDerm™. The reduction of the release of proinflammatory cytokines by topically applied TDDSs was compared with the reduction during the presence of the specific cyclooxygenase inhibitor diclofenac in the culture medium. A similar anti-inflammatory efficacy of the topically applied TDDSs in comparison with the use of diclofenac in the culture medium should be achieved. Furthermore, percutaneous absorption in efficacy tests was compared with percutaneous absorption in diffusion studies with porcine cadaver skin. Both the topically applied TDDSs showed a significant anti-inflammatory activity. Permeation coefficients through the stratum corneum and the epidermis gained from the release studies on porcine cadaver skin (Magnolia: 2.23·10(-5) cm/h, licorice: 4.68·10(-6) cm/h) were approximately five times lower than the permeation coefficients obtained with the EpiDerm™ skin model (Magnolia: 9.48·10(-5) cm/h, licorice: 24.0·10(-6) cm/h). Therefore, an adjustment of drug doses during experiments with the EpiDerm™ skin model because of weaker skin barrier properties should be considered.

  9. Second Order Kinetic Modeling of Headspace Solid Phase Microextraction of Flavors Released from Selected Food Model Systems

    Directory of Open Access Journals (Sweden)

    Jiyuan Zhang

    2014-09-01

    Full Text Available The application of headspace-solid phase microextraction (HS-SPME has been widely used in various fields as a simple and versatile method, yet challenging in quantification. In order to improve the reproducibility in quantification, a mathematical model with its root in psychological modeling and chemical reactor modeling was developed, describing the kinetic behavior of aroma active compounds extracted by SPME from two different food model systems, i.e., a semi-solid food and a liquid food. The model accounted for both adsorption and release of the analytes from SPME fiber, which occurred simultaneously but were counter-directed. The model had four parameters and their estimated values were found to be more reproducible than the direct measurement of the compounds themselves by instrumental analysis. With the relative standard deviations (RSD of each parameter less than 5% and root mean square error (RMSE less than 0.15, the model was proved to be a robust one in estimating the release of a wide range of low molecular weight acetates at three environmental temperatures i.e., 30, 40 and 60 °C. More insights of SPME behavior regarding the small molecule analytes were also obtained through the kinetic parameters and the model itself.

  10. A biodegradable, sustained-released, prednisolone acetate microfilm drug delivery system effectively prolongs corneal allograft survival in the rat keratoplasty model.

    Directory of Open Access Journals (Sweden)

    Yu-Chi Liu

    Full Text Available Frequent and long-term use of topical corticosteroids after corneal transplantation is necessary to prevent graft rejection. However, it relies heavily on patient compliance, and sustained therapeutic drug levels are often not achieved with administration of topical eye drops. A biodegradable drug delivery system with a controlled and sustained drug release may circumvent these limitations. In this study, we investigated the efficacy of a prednisolone acetate (PA-loaded poly (d,l-lactide-co-ε-caprolactone (PLC microfilm drug delivery system on promoting the survival of allogeneic grafts after penetrating keratoplasty (PK using a rat model. The drug release profiles of the microfilms were characterized (group 1. Subsequently, forty-eight PK were performed in four experimental groups: syngeneic control grafts (group 2, allogeneic control grafts (group 3, allogeneic grafts with subconjunctivally-implanted PA microfilm (group 4, and allogeneic grafts with PA eye drops (group 5; n = 12 in each. PA-loaded microfilm achieved a sustained and steady release at a rate of 0.006-0.009 mg/day, with a consistent aqueous drug concentration of 207-209 ng/ml. The mean survival days was >28 days in group 2, 9.9±0.8 days in group 3, 26.8±2.7 days in group 4, and 26.4±3.4 days in group 5 (P = 0.023 and P = 0.027 compared with group 3. Statistically significant decrease in CD4+, CD163+, CD 25+, and CD54+ cell infiltration was observed in group 4 and group 5 compared with group 3 (P<0.001. There was no significant difference in the mean survival and immunohistochemical analysis between group 4 and group 5. These results showed that sustained PA-loaded microfilm effectively prolongs corneal allograft survival. It is as effective as conventional PA eye drops, providing a promising clinically applicable alternative for patients undergoing corneal transplantation.

  11. Reaction rate estimation of controlled-release antifouling paint binders: Rosin-based systems

    DEFF Research Database (Denmark)

    Meseguer Yebra, Diego; Kiil, Søren; Dam-Johansen, Kim

    2005-01-01

    Biofouling on ship hulls is prevented by the use of antifouling (A/F) paints. Typically, sea water soluble rosin or rosin-derivatives are used as the primary means of adjusting the polishing rate of the current chemically active self-polishing paint systems to a suitable value. Previous studies h...

  12. Analysis of Waste Leak and Toxic Chemical Release Accidents from Waste Feed Delivery (WFD) Diluent System

    Energy Technology Data Exchange (ETDEWEB)

    WILLIAMS, J.C.

    2000-09-15

    Radiological and toxicological consequences are calculated for 4 postulated accidents involving the Waste Feed Delivery (WFD) diluent addition systems. Consequences for the onsite and offsite receptor are calculated. This analysis contains technical information used to determine the accident consequences for the River Protection Project (RPP) Final Safety Analysis Report (FSAR).

  13. Analysis of Waste Leak and Toxic Chemical Release Accidents from Waste Feed Delivery (WFD) Diluent System

    International Nuclear Information System (INIS)

    WILLIAMS, J.C.

    2000-01-01

    Radiological and toxicological consequences are calculated for 4 postulated accidents involving the Waste Feed Delivery (WFD) diluent addition systems. Consequences for the onsite and offsite receptor are calculated. This analysis contains technical information used to determine the accident consequences for the River Protection Project (RPP) Final Safety Analysis Report (FSAR)

  14. Decision support systems - The evaluation of health and environmental impact in a radioactive release

    International Nuclear Information System (INIS)

    Slavnicu, D. S.; Vamanu, D. V.; Gheeorghiu, D.; Vamanu, B. I.; Acasandrei, V. T.; Gheorghiu, A.

    2008-01-01

    The paper illustrates, on a couple of case histories, the experience of a research-oriented team in NIPNE, that is routinely involved in nuclear emergency preparedness and response management activities, with the assimilation, implementation, and application of decision support systems (DSS) of continental reference in Europe, and the development of supportive, domestic radiological assessment tools. (authors)

  15. Lagrangian multiforms and multidimensional consistency

    Energy Technology Data Exchange (ETDEWEB)

    Lobb, Sarah; Nijhoff, Frank [Department of Applied Mathematics, University of Leeds, Leeds LS2 9JT (United Kingdom)

    2009-10-30

    We show that well-chosen Lagrangians for a class of two-dimensional integrable lattice equations obey a closure relation when embedded in a higher dimensional lattice. On the basis of this property we formulate a Lagrangian description for such systems in terms of Lagrangian multiforms. We discuss the connection of this formalism with the notion of multidimensional consistency, and the role of the lattice from the point of view of the relevant variational principle.

  16. Chemical and Biological Defense: DOD Needs Consistent Policies and Clear Processes to Address the Survivability of Weapon Systems Against Chemical and Biological Threats

    National Research Council Canada - National Science Library

    2006-01-01

    DOD, joint, and military service weapon system acquisition policies inconsistently address and do not establish a clear process for considering and testing system chemical and biological survivability...

  17. Development of membranes containing a controlled drug release system for ophthalmological applications

    OpenAIRE

    Pinão, Sílvia Raquel das Neves

    2016-01-01

    The effectiveness of drug administration strongly depends on attainment of an effective drug concentration in the area to be treated, for a sufficient period of time. Nowadays, the most used drug administration method for many eye diseases is delivery through eye drops, although it is very inefficient and can lead to negative side effects. The use of soft contact lenses as drug delivery systems appeared as a promising alternative, due to the prolonged contact with the eye surface, high degree...

  18. Establishment and clinical applications of a portable system for capturing influenza viruses released through coughing.

    Science.gov (United States)

    Hatagishi, Etsuko; Okamoto, Michiko; Ohmiya, Suguru; Yano, Hisakazu; Hori, Toru; Saito, Wakana; Miki, Hiroshi; Suzuki, Yasushi; Saito, Reiko; Yamamoto, Taro; Shoji, Makoto; Morisaki, Yoshihisa; Sakata, Soichiro; Nishimura, Hidekazu

    2014-01-01

    Coughing plays an important role in influenza transmission; however, there is insufficient information regarding the viral load in cough because of the lack of convenient and reliable collection methods. We developed a portable airborne particle-collection system to measure the viral load; it is equipped with an air sampler to draw air and pass it through a gelatin membrane filter connected to a cone-shaped, megaphone-like device to guide the cough airflow to the membrane. The membrane was dissolved in a medium, and the viral load was measured using quantitative real-time reverse transcriptase-polymerase chain reaction and a plaque assay. The approximate viral recovery rate of this system was 10% in simulation experiments to collect and quantify the viral particles aerosolized by a nebulizer. Using this system, cough samples were collected from 56 influenza A patients. The total viral detection rate was 41% (23/56), and the viral loads varied significantly (from <10, less than the detection limit, to 2240 viral gene copies/cough). Viable viruses were detected from 3 samples with ≤18 plaque forming units per cough sample. The virus detection rates were similar among different groups of patients infected with different viral subtypes and during different influenza seasons. Among patients who did not receive antiviral treatment, viruses were detected in one of six cases in the vaccinated group and four of six cases in the unvaccinated group. We found cases with high viral titers in throat swabs or oral secretions but very low or undetectable in coughs and vice versa suggesting other possible anatomical sites where the viruses might be mixed into the cough. Our system is easy to operate, appropriate for bedside use, and is useful for comparing the viral load in cough samples from influenza patients under various conditions and settings. However, further large-scale studies are warranted to validate our results.

  19. Evaluation of the accuracy, consistency, and stability of measurements of the Planck constant used in the redefinition of the international system of units

    Science.gov (United States)

    Possolo, Antonio; Schlamminger, Stephan; Stoudt, Sara; Pratt, Jon R.; Williams, Carl J.

    2018-02-01

    The Consultative Committee for Mass and related quantities (CCM), of the International Committee for weights and measures (CIPM), has recently declared the readiness of the community to support the redefinition of the international system of units (SI) at the next meeting of the General Conference on Weights and Measures (CGPM) scheduled for November, 2018. Such redefinition will replace the international prototype of the Kilogram (IPK), as the definition and sole primary realization of the unit of mass, with a definition involving the Planck constant, h. This redefinition in terms of a fundamental constant of nature will enable widespread primary realizations not only of the kilogram but also of its multiples and sub-multiples, best to address the full range of practical needs in the measurement of mass. We review and discuss the statistical models and statistical data reductions, uncertainty evaluations, and substantive arguments that support the verification of several technical preconditions for the redefinition that the CCM has established, and whose verification the CCM has affirmed. These conditions relate to the accuracy and mutual consistency of qualifying measurement results. We review also an issue that has surfaced only recently, concerning the convergence toward a stable value, of the historical values that the task group on fundamental constants of the committee on Data for Science and Technology CODATA-TGFC has recommended for h over the years, even though the CCM has not deemed this issue to be relevant. We conclude that no statistically significant trend can be substantiated for these recommended values, but note that cumulative consensus values that may be derived from the historical measurement results for h seem to have converged while continuing to exhibit fluctuations that are typical of a process in statistical control. Finally, we argue that the most recent consensus value derived from the best measurements available for h, obtained using

  20. Poly(3-hydroxybutyrate) and Eudragit E microparticles: a release system to enhance the aqueous solubility of felodipine and simvastatin

    International Nuclear Information System (INIS)

    Bazzo, Giovana C.; Pezzini, Bianca R.; Zetola, Melissa; Wagner, Theodoro M.; Caetano, Daniela B.; Boch, Maura; Schmucker, Iara C.; Schucko, Sacha K.

    2009-01-01

    Poor water-soluble drugs are a problem for the development of oral solid dosage forms, since it has great potential for low bioavailability. Thus, release systems that promote the increase of aqueous solubility of these drugs are advantageous. This study aimed to evaluate the feasibility of incorporation of felodipine and simvastatin in polymeric microparticles, to improve the aqueous solubility of the drugs. Microparticles of poly(3-hydroxybutyrate) [PHB] and Eudragit E was prepared by emulsion - solvent evaporation technique and characterized as to morphology and encapsulation efficiency of the drugs. Particles with spherical shapes and high levels of drug encapsulated were obtained. There was a significant increase in aqueous solubility of felodipine and simvastatin after its incorporation into the polymeric microparticles. X-ray diffraction analysis showed the conversion of both drugs to amorphous form, which may have contributed to increased the solubility. (author)

  1. The efficacy of an intraoral fluoride-releasing system in irradiated head and neck cancer patients: a preliminary study.

    Science.gov (United States)

    Meyerowitz, C; Watson, G E

    1998-09-01

    This study compared the anticaries effectiveness of an intraoral fluoride-releasing system, or IFRS, with a standard regimen of daily application of a 1.1 percent neutral sodium fluoride gel in custom trays. Caries protection in subjects in the IFRS group was comparable to that in subjects in the 1.1 percent neutral sodium fluoride group. The subjects all had head or neck cancer and had received radiation therapy, but no more recently than three months before taking part in the study. Overall, IFRS devices were well-tolerated and patient satisfaction was high. The IFRS appears to offer several advantages over the daily application of fluoride gels in custom trays.

  2. PROVANN: Model System for Chronic Exposure of Larval and Adult Fish to Releases from Offshore Petroleum Platforms

    International Nuclear Information System (INIS)

    Reed, M.; Rye, H.; Melbye, A.; Johnsen, S.

    1996-01-01

    Produced water from offshore oil and gas production platforms contains a variety of hydrocarbons, heavy metals, and production chemicals. Vertical and horizontal mixing generally brings concentrations in discharge plumes below level associated with acute effects within 500 or 1000 m of the source. Chronic effects outside this region remain a potential problem. The purpose of PROVANN, the system of models described in this paper, is to assess the potential for chronic effects from produced water. The preliminary focus is on potential bioaccumulation and boimagnification of produced water constituents in the marine food web. Other possible types of chronic effects, such as reduced fecundity, or pheromone response interference, can also be assessed to the extent that such effects may be correlated with exposure. PROVANN simulates 3-dimensional transport, dilution, and degradation of chemicals released into the water, from one or more simultaneous sources. 8 refs., 10 figs., 3 tabs

  3. A mobile dose prediction system based on artificial neural networks for NPP emergencies with radioactive material releases

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Claudio M.N.A.; Schirru, Roberto; Gomes, Kelcio J.; Cunha, José Luiz, E-mail: cmnap@ien.gov.br, E-mail: schirru@lmp.ufrj.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Coordenacao dos Programas de Pos-Graduacao em Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    This work presents the approach of a mobile dose prediction system for NPP emergencies with nuclear material release. The objective is to provide extra support to field teams decisions when plant information systems are not available. However, predicting doses due to atmospheric dispersion of radionuclide generally requires execution of complex and computationally intensive physical models. In order to allow such predictions to be made by using limited computational resources such as mobile phones, it is proposed the use of artificial neural networks (ANN) previously trained (offline) with data generated by precise simulations using the NPP atmospheric dispersion system. Typical situations for each postulated accident and respective source terms, as well as a wide range of meteorological conditions have been considered. As a first step, several ANN architectures have been investigated in order to evaluate their ability for dose prediction in hypothetical scenarios in the vicinity of CNAAA Brazilian NPP, in Angra dos Reis, Brazil. As a result, good generalization and a correlation coefficient of 0.99 was achieved for a validation data set (untrained patterns). Then, selected ANNs have been coded in Java programming language to run as an Android application aimed to plot the spatial dose distribution into a map.In this paper, the general architecture of the proposed system is described; numerical results and comparisons between investigated ANN architectures are discussed; performance and limitations of running the Application into a commercial mobile phone are evaluated and possible improvements and future works are pointed. (author)

  4. Stress and Female Reproductive System: Disruption of Corticotropin-Releasing Hormone/Opiate Balance by Sympathetic Nerve Traffic

    Directory of Open Access Journals (Sweden)

    Farideh Zafari Zangeneh

    2009-09-01

    Full Text Available Nowadays stress is an integral part of everyday living and the physiological and behavioral consequences of exposure to stressful situations have been extensively studied for decades. The stress response is a necessary mechanism but disrupts homeostatic process and it is sub served by a complex system located in both the central nervous system (CNS and the periphery. Stressor-induced activation of the hypothalamus–pituitary–adrenal (HPA axis and the sympathetic nervous system (SNS results in a series of neural and endocrine adaptations known as the "stress response" or "stress cascade." The stress cascade is responsible for allowing the body to make the necessary physiological and metabolic changes required to cope with the demands of a homeostatic challenge. Normal activation of the HPA axis is essential for reproduction, growth, metabolic homeostasis, and responses to stress and they are critical for adapting to changes in the external environment. The regulation of gonadal function in men and women is under the control of the HPA. This regulation is complex and sex steroids are important regulators of GnRH and gonadotropin release through classical feedback mechanisms in the hypothalamus and the pituitary. The present overview focuses on the neuroendocrine infrastructure of the adaptive response to stress and its effects on the female reproductive system

  5. Development of a mobile dose prediction system based on artificial neural networks for NPP emergencies with radioactive material releases

    International Nuclear Information System (INIS)

    Pereira, Claudio M.N.A.; Schirru, Roberto; Gomes, Kelcio J.; Cunha, José L.

    2017-01-01

    This work presents the approach of a mobile dose prediction system for NPP emergencies with nuclear material release. The objective is to provide extra support to field teams decisions when plant information systems are not available. However, predicting doses due to atmospheric dispersion of radionuclide generally requires execution of complex and computationally intensive physical models. In order to allow such predictions to be made by using limited computational resources such as mobile phones, it is proposed the use of artificial neural networks (ANN) previously trained (offline) with data generated by precise simulations using the NPP atmospheric dispersion system. Typical situations for each postulated accident and respective source terms, as well as a wide range of meteorological conditions have been considered. As a first step, several ANN architectures have been investigated in order to evaluate their ability for dose prediction in hypothetical scenarios in the vicinity of CNAAA Brazilian NPP, in Angra dos Reis, Brazil. As a result, good generalization and a correlation coefficient of 0.99 was achieved for a validation data set (untrained patterns). Then, selected ANNs have been coded in Java programming language to run as an Android application aimed to plot the spatial dose distribution into a map. In this paper, the general architecture of the proposed system is described; numerical results and comparisons between investigated ANN architectures are discussed; performance and limitations of running the Application into a commercial mobile phone are evaluated and possible improvements and future works are pointed.

  6. A mobile dose prediction system based on artificial neural networks for NPP emergencies with radioactive material releases

    International Nuclear Information System (INIS)

    Pereira, Claudio M.N.A.; Schirru, Roberto; Gomes, Kelcio J.; Cunha, José Luiz

    2017-01-01

    This work presents the approach of a mobile dose prediction system for NPP emergencies with nuclear material release. The objective is to provide extra support to field teams decisions when plant information systems are not available. However, predicting doses due to atmospheric dispersion of radionuclide generally requires execution of complex and computationally intensive physical models. In order to allow such predictions to be made by using limited computational resources such as mobile phones, it is proposed the use of artificial neural networks (ANN) previously trained (offline) with data generated by precise simulations using the NPP atmospheric dispersion system. Typical situations for each postulated accident and respective source terms, as well as a wide range of meteorological conditions have been considered. As a first step, several ANN architectures have been investigated in order to evaluate their ability for dose prediction in hypothetical scenarios in the vicinity of CNAAA Brazilian NPP, in Angra dos Reis, Brazil. As a result, good generalization and a correlation coefficient of 0.99 was achieved for a validation data set (untrained patterns). Then, selected ANNs have been coded in Java programming language to run as an Android application aimed to plot the spatial dose distribution into a map.In this paper, the general architecture of the proposed system is described; numerical results and comparisons between investigated ANN architectures are discussed; performance and limitations of running the Application into a commercial mobile phone are evaluated and possible improvements and future works are pointed. (author)

  7. Risk assessment and experimental design in the development of a prolonged release drug delivery system with paliperidone

    Directory of Open Access Journals (Sweden)

    Iurian S

    2017-03-01

    Full Text Available Sonia Iurian, Luana Turdean, Ioan Tomuta Department of Pharmaceutical Technology and Biopharmacy, University of Medicine and Pharmacy Iuliu Hatieganu, Cluj-Napoca, Romania Abstract: This study focuses on the development of a drug product based on a risk assessment-based approach, within the quality by design paradigm. A prolonged release system was proposed for paliperidone (Pal delivery, containing Kollidon® SR as an insoluble matrix agent and hydroxypropyl cellulose, hydroxypropyl methylcellulose (HPMC, or sodium carboxymethyl cellulose as a hydrophilic polymer. The experimental part was preceded by the identification of potential sources of variability through Ishikawa diagrams, and failure mode and effects analysis was used to deliver the critical process parameters that were further optimized by design of experiments. A D-optimal design was used to investigate the effects of Kollidon SR ratio (X1, the type of hydrophilic polymer (X2, and the percentage of hydrophilic polymer (X3 on the percentages of dissolved Pal over 24 h (Y1–Y9. Effects expressed as regression coefficients and response surfaces were generated, along with a design space for the preparation of a target formulation in an experimental area with low error risk. The optimal formulation contained 27.62% Kollidon SR and 8.73% HPMC and achieved the prolonged release of Pal, with low burst effect, at ratios that were very close to the ones predicted by the model. Thus, the parameters with the highest impact on the final product quality were studied, and safe ranges were established for their variations. Finally, a risk mitigation and control strategy was proposed to assure the quality of the system, by constant process monitoring. Keywords: pharmaceutical development, quality by design, failure mode effects analysis, Ishikawa diagram, fish-bone diagram, hydrophilic matrix

  8. Controlled release of 18-β-glycyrrhetic acid by nanodelivery systems increases cytotoxicity on oral carcinoma cell line

    Science.gov (United States)

    Cacciotti, Ilaria; Chronopoulou, Laura; Palocci, Cleofe; Amalfitano, Adriana; Cantiani, Monica; Cordaro, Massimo; Lajolo, Carlo; Callà, Cinzia; Boninsegna, Alma; Lucchetti, Donatella; Gallenzi, Patrizia; Sgambato, Alessandro; Nocca, Giuseppina; Arcovito, Alessandro

    2018-07-01

    The topical treatment for oral mucosal diseases is often based on products optimized for dermatologic applications; consequently, a lower therapeutic effect may be present. 18-β-glycyrrhetic acid (GA) is extracted from Glycirrhiza glabra. The first aim of this study was to test the cytotoxicity of GA on PE/CA-PJ15 cells. The second aim was to propose and test two different delivery systems, i.e. nanoparticles and fibers, to guarantee a controlled release of GA in vitro. We used chitosan and poly(lactic-co-glycolic) acid based nanoparticles and polylactic acid fibers. We tested both delivery systems in vitro on PE/CA-PJ15 cells and on normal human gingival fibroblasts (HGFs). The morphology of GA-loaded nanoparticles (GA-NPs) and fibers (GA-FBs) was investigated by electron microscopy and dynamic light scattering; GA release kinetics was studied spectrophotometrically. MTT test was used to assess GA cytotoxicity on both cancer and normal cells. Cells were exposed to different concentrations of GA (20–500 μmol l‑1) administered as free GA (GA-f), and to GA-NPs or GA-FBs. ROS production was evaluated using dichlorodihydrofluorescein as a fluorescent probe. Regarding the cytotoxic effect of GA on PE/CA-PJ15 cells, the lowest TC50 value was 200 μmol l‑1 when GA was added as GA-NPs. No cytotoxic effects were observed when GA was administered to HGFs. N-acetyl Cysteine reduced mortality induced by GA-f in PE/CA-PJ15 cells. The specific effect of GA on PE/CA-PJ15 cells is mainly due to the different sensitivity of cancer cells to ROS over-production; GA-NPs and GA-FBs formulations increase, in vitro, this toxic effect on oral cancer cells.

  9. Continuous Release-Emergency Response Notification System and Priority Assessment Model: Model documentation

    International Nuclear Information System (INIS)

    1991-01-01

    The purpose of the model documentation is to provide a detailed description of the modeling and risk analysis procedures used in CR-ERNS/PAM to assist OSCs and other Superfund decision-makers in interpreting the system results. PAM is a screening-level model; to properly interpret PAM's outputs, the user must understand the limitations and uncertainties in the equations and data used to generate these results. Chapter 2 presents the system's fate and transport models and describes the assumptions associated with these equations. Chapter 3 describes PAM's auxiliary data bases and provides the source(s) of each parameter and the methods by which values were selected. Chapter 4 explains the methods and exposure assumptions used to estimate exposures to hazardous substances and to evaluate the risks and hazards associated with these exposures. Chapter 5 presents examples of reports generated by PAM and explains the meaning of the 'flags' assigned to hazardous substances, media, and facilities. Appendix A contains versions of the fate and transport equations used for radionuclides. Appendix B contains copies of PAM's reports

  10. Fostering cooperation in power asymmetrical water systems by the use of direct release rules and index-based insurance schemes

    Science.gov (United States)

    Denaro, Simona; Castelletti, Andrea; Giuliani, Matteo; Characklis, Gregory W.

    2018-05-01

    In river basin systems, power asymmetry is often responsible of inefficient and unbalanced water allocations. Climate change and anthropogenic pressure will possibly exacerbate such disparities as the dominant party controls an increasingly limited shared resource. In this context, the deployment of cooperation mechanisms giving greater consideration to a balanced distribution of the benefits, while improving system-wide efficiency, may be desirable. This often implies the intervention of a third party (e.g., the river basin water authority) imposing normative constraints (e.g., a minimum release) on the party in the dominant position. However, this imposition will be more acceptable to the dominant party if coupled with some form of compensation. For a public agency, compensation may be burdensome, especially when the allowance is triggered by natural events whose timing and magnitude are highly uncertain. In this context, index-based insurance contracts may represent a viable alternative and reduce the cost of achieving socially desirable outcomes. In this paper, we develop a hybrid cooperation mechanism composed of i) a direct normative constraint imposed by a regulator, and ii) an indirect financial tool, an index-based insurance contract, to be used as a compensation measure. The approach is developed for the Lake Como multi-purpose water system, Italy: a complex Alpine river basin, supporting several hydropower reservoirs and finally flowing into a regulated lake which supplies water to several downstream uses, mostly irrigated agriculture. The system is characterized by a manifest geographic power asymmetry: the upstream hydropower companies are free to release their stored water in time irrespective of the timing of the downstream demands. This situation can lead to financial losses by the downstream users and undesirable social outcomes. Results suggest that financial instruments may offer a reliable and relatively inexpensive alternative to other forms of

  11. Development of a multiparticulate system containing enteric-release mini-tablets of omeprazole

    Directory of Open Access Journals (Sweden)

    Volnei Jose Tondo Filho

    2014-09-01

    Full Text Available The main aim of this study was to develop a multiparticulate system containing mini-tablets of omeprazole formulated with an enteric polymer with pH-dependent solubility. Pre-formulation studies showed good flow and compaction capacity, leading to the production ofhigh quality mini-tablets. The mini-tablets were coated in a fluidized bed with hydroxypropylmethylcellulose /Eudragit(r L30D55 and packed into hard gelatin capsules. The dissolution profile showed gastro-resistance and zero-order kinetics. The dissolution profile for the formulation containing lactose as the diluent and coated with 12% (tablet weight gain of polymer was similar to that ofthe reference drug.

  12. Bead Capture and Release on a Magnetic Sensor in a Microfluidic System

    DEFF Research Database (Denmark)

    Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad; Freitas, S.C.

    Planar Hall effect magnetic sensors for detection of biological agents using surface treated magnetic beads are integrated with a fluid injection system. The response of the sensors is used to evaluate bead capture rates for different bead concentrations c and fluid flow rates Q, and to monitor...... subsequent removal of the beads. It is found that the capture rate scales directly with c and that it depends linearly on Q. At low Q the capture rate is only partially due to gravitational sedimentation of beads. At higher Q an additional term proportional to Q becomes important, which is attributed...... to capture of beads by the magnetic fields near the sensor. It is shown that beads can be washed off the sensor surface....

  13. Q2 - a very low level quantitative and qualitative waste assay and release certification system

    International Nuclear Information System (INIS)

    Bronson, F.L.

    1990-01-01

    Low level radioactive waste disposal is very expensive, especially when all of the handling transportation and documentation costs are included. However for most generators, a large fraction of this low level waste is not contaminated at all, or only slightly so. The paper describes the development and performance of a low level counter that is convenient to use, and that can accurately identify and quantify the radioactivity of any gamma emitter thing that can be placed in a 55 gallon (200 liter) container. These measurement results can be used to verify the absence of radioactivity at a very low levels (10 nCi (370 Bq)/sample), and to identify the nuclides and quantities present, while differentiating against natural radioactivity (Radium, Thorium, Potassium). These results can be used as part of a 10CFR20.302 waste stream exemption program, and thus allow significant savings and a less than 1 year payback at a typical nuclear power plant. The Q1 system is fully shielded to allow it's use in the low level radwaste storage area. The detectors are either 3 Intrinsic Germanium detectors or 2 large NaI detectors. The software is fully automated for simple operation. Correlation factors can be entered to estimate non-gamma emitters from pre-established correlations to other nuclides. Typical Ge detector sensitivities are 8 nCi (300 Bq) LLD for Cs-137 at 0.8 g/cc for a 10 minute count time. NaI detector systems can achieve the same LLD in a 1 minute count. 5 figs., 1 tab

  14. Feeding Releases Endogenous Opioids in Humans.

    Science.gov (United States)

    Tuulari, Jetro J; Tuominen, Lauri; de Boer, Femke E; Hirvonen, Jussi; Helin, Semi; Nuutila, Pirjo; Nummenmaa, Lauri

    2017-08-23

    The endogenous opioid system supports a multitude of functions related to appetitive behavior in humans and animals, and it has been proposed to govern hedonic aspects of feeding thus contributing to the development of obesity. Here we used positron emission tomography to investigate whether feeding results in hedonia-dependent endogenous opioid release in humans. Ten healthy males were recruited for the study. They were scanned with the μ-opioid-specific ligand [ 11 C]carfentanil three times, as follows: after a palatable meal, a nonpalatable meal, and after an overnight fast. Subjective mood, satiety, and circulating hormone levels were measured. Feeding induced significant endogenous opioid release throughout the brain. This response was more pronounced following a nonpalatable meal versus a palatable meal, and independent of the subjective hedonic responses to feeding. We conclude that feeding consistently triggers cerebral opioid release even in the absence of subjective pleasure associated with feeding, suggesting that metabolic and homeostatic rather than exclusively hedonic responses play a role in the feeding-triggered cerebral opioid release. SIGNIFICANCE STATEMENT The endogenous opioid system supports both hedonic and homeostatic functions. It has been proposed that overeating and concomitant opioid release could downregulate opioid receptors and promote the development of obesity. However, it remains unresolved whether feeding leads to endogenous opioid release in humans. We used in vivo positron emission tomography to test whether feeding triggers cerebral opioid release and whether this response is associated with pleasurable sensations. We scanned volunteers using the μ-opioid receptor-specific radioligand [ 11 C]carfentanil three times, as follows: after an overnight fast, after consuming a palatable meal, and after consuming a nonpalatable meal. Feeding led to significant endogenous opioid release, and this occurred also in the absence of feeding

  15. Using self-consistent Gibbs free energy surfaces to calculate size distributions of neutral and charged clusters for the sulfuric acid-water binary system

    Science.gov (United States)

    Smith, J. A.; Froyd, K. D.; Toon, O. B.

    2012-12-01

    We construct tables of reaction enthalpies and entropies for the association reactions involving sulfuric acid vapor, water vapor, and the bisulfate ion. These tables are created from experimental measurements and quantum chemical calculations for molecular clusters and a classical thermodynamic model for larger clusters. These initial tables are not thermodynamically consistent. For example, the Gibbs free energy of associating a cluster consisting of one acid molecule and two water molecules depends on the order in which the cluster was assembled: add two waters and then the acid or add an acid and a water and then the second water. We adjust the values within the tables using the method of Lagrange multipliers to minimize the adjustments and produce self-consistent Gibbs free energy surfaces for the neutral clusters and the charged clusters. With the self-consistent Gibbs free energy surfaces, we calculate size distributions of neutral and charged clusters for a variety of atmospheric conditions. Depending on the conditions, nucleation can be dominated by growth along the neutral channel or growth along the ion channel followed by ion-ion recombination.

  16. Effects of Sex Steroids on the Spinal Gastrin-Releasing Peptide System Controlling Male Sexual Function in Rats.

    Science.gov (United States)

    Oti, Takumi; Takanami, Keiko; Ito, Saya; Ueda, Takashi; Matsuda, Ken Ichi; Kawata, Mitsuhiro; Soh, Jintetsu; Ukimura, Osamu; Sakamoto, Tatsuya; Sakamoto, Hirotaka

    2018-04-01

    The gastrin-releasing peptide (GRP) system in the lumbosacral spinal cord controls male sexual function in rats. In contrast, in female rats, GRP neurons could scarcely be detected around puberty when circulating ovarian steroid hormones such as estradiol and progesterone levels are increasing. However, little information is available on feminizing or demasculinizing effects of ovarian steroids on the central nervous system in female puberty and adulthood. In this study, to visualize the spinal GRP neurons in vivo, we generated a GRP-promoter-Venus transgenic (Tg) rat line and studied the effects of the sex steroid hormones on GRP expression in the rat lumbar cord by examining the Venus fluorescence. In these Tg rats, the sexually dimorphic spinal GRP neurons controlling male sexual function were clearly labeled with Venus fluorescence. As expected, Venus fluorescence in the male lumbar cord was markedly decreased after castration and restored by chronic androgen replacement. Furthermore, androgen-induced Venus expression in the spinal cord of adult Tg males was significantly attenuated by chronic treatment with progesterone but not with estradiol. A luciferase assay using a human GRP-promoter construct showed that androgens enhance the spinal GRP system, and more strikingly, that progesterone acts to inhibit the GRP system via an androgen receptor-mediated mechanism. These results demonstrate that circulating androgens may play an important role in the spinal GRP system controlling male sexual function not only in rats but also in humans and that progesterone could be an important feminizing factor in the spinal GRP system in females during pubertal development.

  17. Development of Public Training System for Emergency Exercise Using Virtual Reality Technology Based on Radioactive Release Accident

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Il; Park, Seong Jun; Lee, Dewhey; Song, Sub Lee; Park, Younwon [BEES Inc., Daejeon (Korea, Republic of)

    2016-10-15

    An exercise is normally conducted for a day or two days depending on the scale of the exercise. What we have experienced up to date there are several limitations in the radiological emergency exercises such as low public acceptance, poor enthusiasm in the exercise participation, not very attracting exercise scenarios, low efficiency in conducting an exercise, and so on. In order to overcome the limitations of the present exercising system, we would like to develop a radiological emergency exercise system using VR (virtual reality) technology based on a radioactive release accident. In this paper, we just introduce some basic development methods and event tree based scenario as a beginning stage. After the accident in Fukushima Daiichi NPP, the importance of emergency exercise especially for the public is far more emphasized around the world more and more. However, the human labor focused radiological emergency exercise up to now has many limitations. After developing this system properly and by using it, we could even expect to estimate the weak points of the emergency arrangements and strategy we have.