WorldWideScience

Sample records for release rate testing

  1. Setting accelerated dissolution test for PLGA microspheres containing peptide, investigation of critical parameters affecting drug release rate and mechanism.

    Science.gov (United States)

    Tomic, I; Vidis-Millward, A; Mueller-Zsigmondy, M; Cardot, J-M

    2016-05-30

    The objective of this study was development of accelerated in vitro release method for peptide loaded PLGA microspheres using flow-through apparatus and assessment of the effect of dissolution parameters (pH, temperature, medium composition) on drug release rate and mechanism. Accelerated release conditions were set as pH 2 and 45°C, in phosphate buffer saline (PBS) 0.02M. When the pH was changed from 2 to 4, diffusion controlled phases (burst and lag) were not affected, while release rate during erosion phase decreased two-fold due to slower ester bonds hydrolyses. Decreasing temperature from 45°C to 40°C, release rate showed three-fold deceleration without significant change in release mechanism. Effect of medium composition on drug release was tested in PBS 0.01M (200 mOsm/kg) and PBS 0.01M with glucose (380 mOsm/kg). Buffer concentration significantly affected drug release rate and mechanism due to the change in osmotic pressure, while ionic strength did not have any effect on peptide release. Furthermore, dialysis sac and sample-and-separate techniques were used, in order to evaluate significance of dissolution technique choice on the release process. After fitting obtained data to different mathematical models, flow-through method was confirmed as the most appropriate for accelerated in vitro dissolution testing for a given formulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Evaluation of fuel release rate and mechanism tests under RBCB conditions

    International Nuclear Information System (INIS)

    Adamson, M.G.

    1981-09-01

    This task includes theoretical evaluation of fuel/fission product release behavior from failed LMFBR fuel elements as well as an on-going experimental investigation of the mechanism of oxide fuel dispersal into flowing liquid sodium. The primary objectives of this work are to develop a fuel source term that can be used in predictive models for primary heat transfer system contamination and to understand the separate influences of important system variables (such as flow rate, oxygen impurity level) on this source term. The present report is written in two parts: the first, in condensed form, is an updated evaluation of fuel (U,Pu) and fission product release data, and the second describes the current status of supporting experimental work at General Electric's Vallecitos Laboratory

  3. Diffusion rates for elevated releases

    International Nuclear Information System (INIS)

    Ramsdell, J.V.

    1983-11-01

    A search of the literature related to diffusion from elevated sources has determined that an adequate data base exists for use in developing parameterizations for estimating diffusion rates for material released from free standing stacks at nuclear power plants. A review of published data analyses indicates that a new parameterization of horizontal diffusion rates specifically for elevated releases is not likely to significantly change the magnitudes of horizontal diffusion coefficients on the average. However, the uncertainties associated with horizontal diffusion coefficient estimates under any given set of atmospheric conditions could be reduced by a new parameterization. Similarly, a new parameterization of vertical diffusion rates would be unlikely to significantly alter the magnitudes of diffusion coefficients for unstable atmospheric conditons. However, for neutral and stable atmospheric conditions, a new parameterization of vertical diffusion rates might increase vertical diffusion coefficients significantly. The increase would move ground-level time-integrated concentration maxima closer to the plant and would increase the maxima. 55 references, 2 figures, 4 tables

  4. Heat release rate of wood-plastic composites

    Science.gov (United States)

    N. M. Stark; R. H. White; C. M. Clemons

    1997-01-01

    Wood-plastic composites are becoming more important as a material that fulfills recycling needs. In this study, fire performance tests were conducted on several compositions of wood and plastic materials using the Ohio State University rate of heat release apparatus. Test results included five-minute average heat release rate in kW/m2 (HRR avg) and maximum heat release...

  5. Corrosion Tests of LWR Fuels - Nuclide Release

    International Nuclear Information System (INIS)

    P.A. Finn; Y. Tsai; J.C. Cunnane

    2001-01-01

    Two BWR fuels [64 and 71 (MWd)/kgU], one of which contained 2% Gd, and two PWR fuels [30 and 45 (MWd)/kgU], are tested by dripping groundwater on the fuels under oxidizing and hydrologically unsaturated conditions for times ranging from 2.4 to 8.2 yr at 90 C. The 99 Tc, 129 I, 137 Cs, 97 Mo, and 90 Sr releases are presented to show the effects of long reaction times and of gadolinium on nuclide release. This investigation showed that the five nuclides at long reaction times have similar fractional release rates and that the presence of 2% Gd reduced the 99 Tc cumulative release fraction by about an order of magnitude over that of a fuel with a similar burnup

  6. Ririe Dam Release Test Assessment

    Science.gov (United States)

    2013-06-01

    Notes HEC - RAS Location Station (ft) Observation Notes 1420 Ririe Dam Ririe Dam 119,880 Gates opened and initial release started. 1455 115th St...16°F air temperature. Table A2. Observations made on 11 February 2013. Time Location Notes HEC - RAS Location Station (ft) Observation Notes...ERDC/CRREL TR-13-10 52 Time Location Notes HEC - RAS Location Station (ft) Observation Notes Travel Time* (sec) Vel.** (fps) 1224 5th

  7. The surface-forming energy release rate versus the local energy release rate

    OpenAIRE

    Xiao, Si; Wang, He-ling; Landis, Chad M; Hwang, Keh-Chih; Liu, Bin

    2016-01-01

    This paper identifies two ways to extract the energy (or power) flowing into a crack tip during propagation based on the power balance of areas enclosed by a stationary contour and a comoving contour. It is very interesting to find a contradiction that two corresponding energy release rates (ERRs), a surface-forming ERR and a local ERR, are different when stress singularity exists at a crack tip. Besides a rigorous mathematical interpretation, we deduce that the stress singularity leads to an...

  8. Release rates from waste packages in a salt repository

    International Nuclear Information System (INIS)

    Chambre, P.L.; Hwang, Y.; Lee, W.W.L.; Pigford, T.H.

    1987-06-01

    In this report we present estimates of radionuclide release rates from waste packages into salt. This conservative and bounding analysis shows that release rates from waste packages in salt are well below the US Nuclear Regulatory Commission's performance objectives for the engineered barrier system. 2 refs., 2 figs

  9. ACRR fission product release tests: ST-1 and ST-2

    International Nuclear Information System (INIS)

    Allen, M.D.; Stockman, H.W.; Reil, K.O.; Grimley, A.J.; Camp, W.J.

    1988-01-01

    Two experiments (ST-1 and ST-2) have been performed in the Annular Core Research Reactor (ACRR) at Sandia National Laboratories (SNLA) to obtain time-resolved data on the release of fission products from irradiated fuels under light water reactor (LWR) severe accident conditions. Both experiments were conducted in a highly reducing environment at maximum fuel temperatures of greater than 2400 K. These experiments were designed specifically to investigate the effect of increased total pressure on fission product release; ST-1 was performed at approximately 0.16 MPa and ST-2 was run at 1.9 MPa, whereas other parameters were matched as closely as possible. Release rate data were measured for Cs, I, Ba, Sr, Eu, Te, and U. The release rates were higher than predicted by existing codes for Ba, Sr, Eu, and U. Te release was very low, but Te did not appear to be sequestered by the zircaloy cladding; it was evenly distributed in the fuel. In addition, in posttest analysis a unique fuel morphology (fuel swelling) was observed which may have enhanced fission product release, especially in the high pressure test (ST-2). These data are compared with analytical results from the CORSOR correlation and the VICTORIA computer model

  10. Controlling Object Heat Release Rate using Geometrical Features

    OpenAIRE

    Kraft, Stefan Marc

    2017-01-01

    An experimental study was conducted to determine the effect of complex geometries on the burning rate of materials made using additive manufacturing. Controlling heat release rate has applicability in limiting fire hazards as well as for designing fuels for optimal burning rate. The burning rate of a structure is a function of the material properties as well as the airflow through it, which is dictated by the geometry. This burning rate is generally proportional to the porosity for obj...

  11. The burning and smoke release rates of sodium pool fires

    International Nuclear Information System (INIS)

    Newman, R.N.; Payne, J.F.B.

    1976-10-01

    The burning rates and smoke release fractions of sodium pool fires have been measured over the pool temperature range 250 0 C to 750 0 C. A theoretical model is derived which satisfactorily predicts the burning rate over the above temperature range. The theory further predicts that the burning rate should be independent of pool diameter, a prediction supported by a comparison of burning rate data from this study and available data from other studies. (author)

  12. Comprehensive Error Rate Testing (CERT)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Centers for Medicare and Medicaid Services (CMS) implemented the Comprehensive Error Rate Testing (CERT) program to measure improper payments in the Medicare...

  13. Release rates of soluble species at Yucca Mountain

    International Nuclear Information System (INIS)

    Lee, W.W.-L.; Pigford, T.H.

    1989-02-01

    Experimental leaching of spent fuel shows that some fission product species are preferentially released upon contact with water. We analyze the conservative case of bare spent fuel in contact with saturated tuff using diffusional mass transfer analysis. For the parameter values used, the USNRC release rate limit is not exceeded, except for 99 Tc. The presence of a container and the distribution of water contact over time will assist in meeting this criterion. 6 figs., 2 tabs

  14. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  15. Fracture patterns and the energy release rate of phosphorene.

    Science.gov (United States)

    Liu, Ning; Hong, Jiawang; Pidaparti, Ramana; Wang, Xianqiao

    2016-03-14

    Phosphorene, also known as monolayer black phosphorus, has been enjoying popularity in electronic devices due to its superior electrical properties. However, it's relatively low Young's modulus, low fracture strength and susceptibility to structural failure have limited its application in mechanical devices. Therefore, in order to design more mechanically reliable devices that utilize phosphorene, it is necessary to explore the fracture patterns and energy release rate of phosphorene. In this study, molecular dynamics simulations are performed to investigate phosphorene's fracture mechanism. The results indicate that fracture under uniaxial tension along the armchair direction is attributed to a break in the interlayer bond angles, while failure in the zigzag direction is triggered by the break in both intra-layer angles and bonds. Furthermore, we developed a modified Griffith criterion to analyze the energy release rate of phosphorene and its dependence on the strain rates and orientations of cracks. Simulation results indicate that phosphorene's energy release rate remains almost unchanged in the armchair direction while it fluctuates intensively in the zigzag direction. Additionally, the strain rate was found to play a negligible role in the energy release rate. The geometrical factor α in the Griffith's criterion is almost constant when the crack orientation is smaller than 45 degree, regardless of the crack orientation and loading direction. Overall, these findings provide helpful insights into the mechanical properties and failure behavior of phosphorene.

  16. Release rate of diazinon from microcapsule based on melamine formaldehyde

    Science.gov (United States)

    Noviana Utami C., S.; Rochmadi

    2018-04-01

    The microcapsule containing diazinon as the core material and melamine formaldehyde as the membrane material have been synthesized by in situ polymerization method. The microcapsule membrane in this research is melamine formaldehyde (MF). This research aims to study the effect of pH and temperature on the release rate of diazinon from microcapsule based on melamine formaldehyde in aqueous medium. The results showed that pH and temperature has little effect on the release rate of diazinon from microcapsule based on melamine formaldehyde. This is due to the diffusion through the microcapsule membrane is not influenced by the pH and temperature of the solution outside of microcapsule.

  17. Heat release rate from the combustion of uranium

    International Nuclear Information System (INIS)

    Solbrig, C.W.

    1995-01-01

    Fuel treatment is planned at the Argonne National Laboratory on EBR-II spent fuel. The electrochemical treatment process is carried out in a cell with an argon atmosphere to prevent any reaction. The amount of fuel processed at any time is limited by the amount of energy which could be released by metal combustion if air is inadvertently allowed into the cell since the heat release would increase the cell pressure. The cell pressure is required to be below atmospheric even if combustion occurs to ensure no cell gas/aerosol is released to the environment. Metal fires can release large amounts of heat. In certain configurations such as fine particulate, metal can be pyrophoric at room temperature. When the metal is a nuclear fuel, it is important to be able to predict the reaction/heat release rate if the metal is inadvertently exposed to air. A realistic combustion model is needed to predict heat release rates for the many different flow and transport configurations which exist in the various fuel processing steps. A model for the combustion of uranium is developed here which compares satisfactorily to experimental data

  18. Radiological effluents released from US continental tests, 1961 through 1992. Revision 1

    International Nuclear Information System (INIS)

    Schoengold, C.R.; DeMarre, M.E.; Kirkwood, E.M.

    1996-08-01

    This report documents all continental tests from September 15, 1961, through September 23, 1992, from which radioactive effluents were released. The report includes both updated information previously published in the publicly available May, 1990 report, DOE/NV-317, ''Radiological Effluents Released from Announced US Continental Tests 1961 through 1988'', and effluent release information on formerly unannounced tests. General information provided for each test includes the date, time, location, type of test, sponsoring laboratory and/or agency or other sponsor, depth of burial, purpose, yield or yield range, extent of release (onsite only or offsite), and category of release (detonation-time versus post-test operations). Where a test with simultaneous detonations is listed, location, depth of burial and yield information are given for each detonation if applicable, as well as the specific source of the release. A summary of each release incident by type of release is included. For a detonation-time release, the effluent curies are expressed at R+12 hours. For a controlled releases from tunnel-tests, the effluent curies are expressed at both time of release and at R+12 hours. All other types are listed at the time of the release. In addition, a qualitative statement of the isotopes in the effluent is included for detonation-time and controlled releases and a quantitative listing is included for all other types. Offsite release information includes the cloud direction, the maximum activity detected in the air offsite, the maximum gamma exposure rate detected offsite, the maximum iodine level detected offsite, and the maximum distance radiation was detected offsite. A release summary incudes whatever other pertinent information is available for each release incident. This document includes effluent release information for 433 tests, some of which have simultaneous detonations. However, only 52 of these are designated as having offsite releases

  19. Radiological effluents released from US continental tests, 1961 through 1992. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Schoengold, C.R.; DeMarre, M.E.; Kirkwood, E.M.

    1996-08-01

    This report documents all continental tests from September 15, 1961, through September 23, 1992, from which radioactive effluents were released. The report includes both updated information previously published in the publicly available May, 1990 report, DOE/NV-317, ``Radiological Effluents Released from Announced US Continental Tests 1961 through 1988``, and effluent release information on formerly unannounced tests. General information provided for each test includes the date, time, location, type of test, sponsoring laboratory and/or agency or other sponsor, depth of burial, purpose, yield or yield range, extent of release (onsite only or offsite), and category of release (detonation-time versus post-test operations). Where a test with simultaneous detonations is listed, location, depth of burial and yield information are given for each detonation if applicable, as well as the specific source of the release. A summary of each release incident by type of release is included. For a detonation-time release, the effluent curies are expressed at R+12 hours. For a controlled releases from tunnel-tests, the effluent curies are expressed at both time of release and at R+12 hours. All other types are listed at the time of the release. In addition, a qualitative statement of the isotopes in the effluent is included for detonation-time and controlled releases and a quantitative listing is included for all other types. Offsite release information includes the cloud direction, the maximum activity detected in the air offsite, the maximum gamma exposure rate detected offsite, the maximum iodine level detected offsite, and the maximum distance radiation was detected offsite. A release summary incudes whatever other pertinent information is available for each release incident. This document includes effluent release information for 433 tests, some of which have simultaneous detonations. However, only 52 of these are designated as having offsite releases.

  20. H2S release rate assessment guidelines and audit forms

    International Nuclear Information System (INIS)

    Johnson, S.; Wilson, T.; Long, R.; Shewan, K.; Nchkalo, H.; Nelson, R.; Morand, M.

    1998-01-01

    Development of a process to evaluate and calculate potential hydrogen sulfide release has been recommended by the Canadian Association of Petroleum Producers' Drilling and Completion Committee, and the Alberta Energy and Utilities Board. To facilitate the process, CAPP has released guidelines describing a methodology and standard for the industry to calculate the potential hydrogen sulfide release rates of a well, and a standardized format for the documentation and retention of data. The Guidelines describe a four-step process, with each step having an increasing degree of complexity. Step One describes the zone hydrogen sulfide exclusion area maps, defining when reporting is to be used (based on well location and distance from inhabited areas). Step Two provides details of the recommended method for determining hydrogen sulfide release through a data search process. Step Three consists of a series of instructions in the use of geologic analogs, data editing and wellbore design to further refine the cumulative hydrogen sulfide release rate. Step Four contains information designed to assist in detailed geological and reservoir modeling. It is not necessary to use all four steps in all cases. The user, however, is advised to use sound engineering judgement and due diligence in the calculation decisions. Sample calculations are provided for a variety of different situations. Measurement techniques are described in an appendix. A completed example of an audit form is attached. 10 + 6 refs., tabs

  1. Evaluation of rate of swelling and erosion of verapamil (VRP) sustained-release matrix tablets.

    Science.gov (United States)

    Khamanga, Sandile M; Walker, Roderick B

    2006-01-01

    Tablets manufactured in-house were compared to a marketed sustained-release product of verapamil to investigate the rate of hydration, erosion, and drug-release mechanism by measuring the wet and subsequent dry weights of the products. Swelling and erosion rates depended on the polymer and granulating fluid used, which ultimately pointed to their permeability characteristics. Erosion rate of the marketed product was highest, which suggests that the gel layer that formed around these tablets was weak as opposed to the robust and resistant layers of test products. Anomalous and near zero-order transport mechanisms were dominant in tests and commercial product, respectively.

  2. Measurement of very low release rates of corrosion products in high temperature water

    International Nuclear Information System (INIS)

    Hermansson, H.-P.; Falk, I.

    1984-01-01

    A radiotracer technique has been developed for the measurement of release rates from nuclear reactor materials and it has been tested in a number of experiments. THis article, which forms the first part in a series, describes the experimental loop, the experimental technique and the preliminary results. Experiments were carried out on 18Cr8Ni stainless steel and on Inconel X750 in BWR primary system and feed water environments. The result show that a steady state in the release rate is achieved after operation for approximately 600 h. The release rate depends on the elemental concentration in the material and on the chemical and physical environments. Typical release rates for an 18Cr8Ni stainless steel and Inconel X750 in a BWR primary system environment were found to be 5 mdm and 8 mdm respectively. (Authors)

  3. Relationship among reaction rate, release rate and efficiency of nanomachine-based targeted drug delivery.

    Science.gov (United States)

    Zhao, Qingying; Li, Min; Luo, Jun

    2017-12-04

    In nanomachine applications towards targeted drug delivery, drug molecules released by nanomachines propagate and chemically react with tumor cells in aqueous environment. If the nanomachines release drug molecules faster than the tumor cells react, it will result in loss and waste of drug molecules. It is a potential issue associated with the relationship among reaction rate, release rate and efficiency. This paper aims to investigate the relationship among reaction rate, release rate and efficiency based on two drug reception models. We expect to pave a way for designing a control method of drug release. We adopted two analytical methods that one is drug reception process based on collision with tumors and another is based on Michaelis Menten enzymatic kinetics. To evaluate the analytical formulations, we used the well-known simulation framework N3Sim to establish simulations. The analytical results of the relationship among reaction rate, release rate and efficiency is obtained, which match well with the numerical simulation results in a 3-D environment. Based upon two drug reception models, the results of this paper would be beneficial for designing a control method of nanomahine-based drug release.

  4. Accelerated in-vitro release testing methods for extended-release parenteral dosage forms.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-07-01

    This review highlights current methods and strategies for accelerated in-vitro drug release testing of extended-release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in-situ depot-forming systems and implants. Extended-release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, 'real-time' in-vitro release tests for these dosage forms are often run over a long time period. Accelerated in-vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in-vitro release methods using United States Pharmacopeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended-release parenteral dosage forms, along with the accelerated in-vitro release testing methods currently employed are discussed. Accelerated in-vitro release testing methods with good discriminatory ability are critical for quality control of extended-release parenteral products. Methods that can be used in the development of in-vitro-in-vivo correlation (IVIVC) are desirable; however, for complex parenteral products this may not always be achievable. © 2012 The Authors. JPP © 2012 Royal Pharmaceutical Society.

  5. Accelerated in vitro release testing methods for extended release parenteral dosage forms

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J.

    2012-01-01

    Objectives This review highlights current methods and strategies for accelerated in vitro drug release testing of extended release parenteral dosage forms such as polymeric microparticulate systems, lipid microparticulate systems, in situ depot-forming systems, and implants. Key findings Extended release parenteral dosage forms are typically designed to maintain the effective drug concentration over periods of weeks, months or even years. Consequently, “real-time” in vitro release tests for these dosage forms are often run over a long time period. Accelerated in vitro release methods can provide rapid evaluation and therefore are desirable for quality control purposes. To this end, different accelerated in vitro release methods using United States Pharmacopoeia (USP) apparatus have been developed. Different mechanisms of accelerating drug release from extended release parenteral dosage forms, along with the accelerated in vitro release testing methods currently employed are discussed. Conclusions Accelerated in vitro release testing methods with good discriminatory ability are critical for quality control of extended release parenteral products. Methods that can be used in the development of in vitro-in vivo correlation (IVIVC) are desirable, however for complex parenteral products this may not always be achievable. PMID:22686344

  6. Effect of crack-microcracks interaction on energy release rates

    Science.gov (United States)

    Chudnovsky, A.; Wu, Shaofu

    1990-01-01

    The energy release rates associated with the main crack advancing into its surrounding damage zone, and the damage zone translation relative to the main crack, as well as the energy of interaction between the crack and the damage zone are analyzed. The displacement and stress fields for this crack-damage interaction problem are reconstructed by employing a semi-empirical stress analysis which involves experimental evaluation of the average microcrack density in the damage zone.

  7. Radionuclide release rates from spent fuel for performance assessment modeling

    International Nuclear Information System (INIS)

    Curtis, D.B.

    1994-01-01

    In a scenario of aqueous transport from a high-level radioactive waste repository, the concentration of radionuclides in water in contact with the waste constitutes the source term for transport models, and as such represents a fundamental component of all performance assessment models. Many laboratory experiments have been done to characterize release rates and understand processes influencing radionuclide release rates from irradiated nuclear fuel. Natural analogues of these waste forms have been studied to obtain information regarding the long-term stability of potential waste forms in complex natural systems. This information from diverse sources must be brought together to develop and defend methods used to define source terms for performance assessment models. In this manuscript examples of measures of radionuclide release rates from spent nuclear fuel or analogues of nuclear fuel are presented. Each example represents a very different approach to obtaining a numerical measure and each has its limitations. There is no way to obtain an unambiguous measure of this or any parameter used in performance assessment codes for evaluating the effects of processes operative over many millennia. The examples are intended to suggest by example that in the absence of the ability to evaluate accuracy and precision, consistency of a broadly based set of data can be used as circumstantial evidence to defend the choice of parameters used in performance assessments

  8. Matrix tablets: the effect of hydroxypropyl methylcellulose/anhydrous dibasic calcium phosphate ratio on the release rate of a water-soluble drug through the gastrointestinal tract I. In vitro tests.

    Science.gov (United States)

    Mamani, Pseidy L; Ruiz-Caro, Roberto; Veiga, María D

    2012-12-01

    Different hydroxypropyl methylcellulose (HPMC)/anhydrous dibasic calcium phosphate (ADCP) matrix tablets have been developed aiming to evaluate the influence of both components ratio in the control release of a water-soluble drug (theophylline). In order to characterise the matrix tablets, swelling, buoyancy and dissolution studies have been carried out in different aqueous media (demineralised water, progressive pH medium, simulated gastric fluid, simulated intestinal fluid and simulated colonic fluid). The HPMC/ADCP ratio has turned out to be the determinant in the matrix behaviour: the HPMC characteristic swelling behaviour was modulated, in some cases, by the ADCP characteristic acidic dissolution. When the HPMC/ADCP ratio was ≥0.69, buoyancy, continuous swelling and low theophylline dissolution rate from the matrices (H1, H2 and H3) were observed in all dissolution media. Consequently, these formulations could be adequate as gastro-retentive drug delivery systems. Additionally, HPMC/ADCP ratio ≤0.11 (H5 and H6) induces a pH-dependent drug release which could be applied to design control drug release enteric formulations (with a suitable enteric coating). Finally, a HPMC/ADCP ratio between 0.11 and 0.69 (H4) yield a gastrointestinal controlled drug release, due to its time-dependent buoyancy (7 h) and a total drug delivery in 17 h in simulated colonic fluid.

  9. Radioisotopic composition of yellowcake: an estimation of stack release rates

    International Nuclear Information System (INIS)

    Momeni, M.H.; Kisieleski, W.E.; Rayno, D.R.; Sabau, C.S.

    1979-12-01

    Uranium concentrate (yellowcake) composites from four mills (Anaconda, Kerr-McGee, Highland, and Uravan) were analyzed for U-238, U-235, U-234, Th-230, Ra-226, and Pb-210. The ratio of specific activities of U-238 to U-234 in the composites suggested that secular radioactive equilibrium exists in the ore. The average activity ratios in the yellowcake were determined to be 2.7 x 10 -3 (Th-230/U-238), 5 x 10 -4 (Ra-226/U-238) and 2 x 10 -4 (Pb-210/U-238). Based on earlier EPA measurements of the release rates from the stacks, the amount of yellowcake released was determined to be 0.1% of the amount processed

  10. 21 CFR 211.165 - Testing and release for distribution.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Laboratory Controls § 211.165 Testing and release for distribution. (a) For each batch of drug product, there shall be... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Testing and release for distribution. 211.165...

  11. Dynamic energy release rate in couple-stress elasticity

    International Nuclear Information System (INIS)

    Morini, L; Piccolroaz, A; Mishuris, G

    2013-01-01

    This paper is concerned with energy release rate for dynamic steady state crack problems in elastic materials with microstructures. A Mode III semi-infinite crack subject to loading applied on the crack surfaces is considered. The micropolar behaviour of the material is described by the theory of couple-stress elasticity developed by Koiter. A general expression for the dynamic J-integral including both traslational and micro-rotational inertial contributions is derived, and the conservation of this integral on a path surrounding the crack tip is demonstrated

  12. Behavior of fission products released from severely damaged fuel during the PBF severe fuel damage tests

    International Nuclear Information System (INIS)

    Osetek, D.J.; Cronenberg, A.W.; Hagrman, D.L.; Broughton, J.M.; Rest, J.

    1984-01-01

    The results of fission product release behavior during the first two Power Burst Facility Severe Fuel Damage tests are presented. Measured fission product release is compared with calculated release using temperature dependent release rate correlations and FASTGRASS analysis. The test results indicate that release from fuel of the high volatility fission products (Xe, Kr, I, Cs, and Te) is strongly influenced by parameters other than fuel temperature; namely fuel/fission product morphology, fuel and cladding oxidation state, extent of fuel liquefaction, and quench induced fuel shattering. Fission product transport from the test fuel through the sample system was strongly influenced by chemical effects. Holdup of I and Cs was affected by fission product chemistry, and transport time while Te release was primarily influenced by the extent of zircaloy oxidation. Analysis demonstrates that such integral test data can be used to confirm physical, chemical, and mechanistic models of fission product behavior for severe accident conditions

  13. Comodulation masking release in bit-rate reduction systems

    DEFF Research Database (Denmark)

    Vestergaard, Martin David; Rasmussen, Karsten Bo; Poulsen, Torben

    1999-01-01

    It has been suggested that the level dependence of the upper masking slope be utilized in perceptual models in bit-rate reduction systems. However, comodulation masking release (CMR) phenomena lead to a reduction of the masking effect when a masker and a probe signal are amplitude modulated...... with the same frequency. In bit-rate reduction systems the masker would be the audio signal and the probe signal would represent the quantization noise. Masking curves have been determined for sinusoids and 1-Bark-wide noise maskers in order to investigate the risk of CMR, when quantizing depths are fixed...... in accordance with psycho-acoustical principles. Masker frequencies of 500 Hz, 1 kHz, and 2 kHz have been investigated, and the masking of pure tone probes has been determined in the first four 1/3 octaves above the masker. Modulation frequencies between 6 and 20 Hz were used with a modulation depth of 0...

  14. Variable temperature effects on release rates of readily soluble nuclides

    International Nuclear Information System (INIS)

    Kim, C.-L.; Light, W.B.; Lee, W.W.-L.; Chambre, P.L.; Pigford, T.H.

    1988-09-01

    In this paper we study the effect of temperature on the release rate of readily soluble nuclides, as affected by a time-temperature dependent diffusion coefficient. In this analysis ground water fills the voids in the waste package at t = 0 and one percent of the inventories of cesium and iodine are immediately dissolved into the void water. Mass transfer resistance of partly failed container and cladding is conservatively neglected. The nuclides move through the void space into the surrounding rock under a concentration gradient. We use an analytic solution to compute the nuclide concentration in the gap or void, and the mass flux rate into the porous rock. 8 refs., 4 figs

  15. Investigating the feasibility of temperature-controlled accelerated drug release testing for an intravaginal ring.

    Science.gov (United States)

    Externbrink, Anna; Clark, Meredith R; Friend, David R; Klein, Sandra

    2013-11-01

    The objective of the present study was to investigate if temperature can be utilized to accelerate drug release from Nuvaring®, a reservoir type intravaginal ring based on polyethylene vinyl acetate copolymer that releases a constant dose of contraceptive steroids over a duration of 3 weeks. The reciprocating holder apparatus (USP 7) was utilized to determine real-time and accelerated etonogestrel release from ring segments. It was demonstrated that drug release increased with increasing temperature which can be attributed to enhanced drug diffusion. An Arrhenius relationship of the zero-order release constants was established, indicating that temperature is a valid parameter to accelerate drug release from this dosage form and that the release mechanism is maintained under these accelerated test conditions. Accelerated release tests are particularly useful for routine quality control to assist during batch release of extended release formulations that typically release the active over several weeks, months or even years, since they can increase the product shelf life. The accelerated method should therefore be able to discriminate between formulations with different release characteristics that can result from normal manufacturing variance. In the case of Nuvaring®, it is well known that the process parameters during the extrusion process strongly influence the polymeric structure. These changes in the polymeric structure can affect the permeability which, in turn, is reflected in the release properties. Results from this study indicate that changes in the polymeric structure can lead to a different temperature dependence of the release rate, and as a consequence, the accelerated method can become less sensitive to detect changes in the release properties. When the accelerated method is utilized during batch release, it is therefore important to take this possible restriction into account and to evaluate the accelerated method with samples from non

  16. FLECHT low flooding rate cosine test series data report

    International Nuclear Information System (INIS)

    Rosal, E.R.; Hochreiter, L.E.; McGuire, M.F.; Krepinevich, M.C.

    1975-12-01

    The FLECHT Low Flooding Rate Tests were conducted in an improved original FLECHT Test Facility to provide heat transfer coefficient and entrainment data at forced flooding rates of 1 in./sec and below. In addition these tests were performed to supplement parametric effects studied in the original FLECHT program, provide data for reflood model development, repeat original FLECHT tests with new instrumentation and data processing techniques, and to provide data to establish test repeatability. These tests examined the effects of low initial clad temperature, variable stepped and continuously variable flooding rates, housing heat release, run peak power, constant low flooding rates, coolant subcooling, hot and cold channel entrainment, and bundle stored and generated power. Data obtained in sixty four runs which met the test specifications are reported, and include rod clad temperatures, turn around and quench times, heat transfer coefficients, inlet flooding rates, overall mass balances, differential pressures and calculated void fractions in the test section, thimble wall and steam temperatures, exhaust steam and liquid carryover rates, and housing total and rate of heat release

  17. The Sympathetic Release Test: A Test Used to Assess Thermoregulation and Autonomic Control of Blood Flow

    Science.gov (United States)

    Tansey, E. A.; Roe, S. M.; Johnson, C. J.

    2014-01-01

    When a subject is heated, the stimulation of temperature-sensitive nerve endings in the skin, and the raising of the central body temperature, results in the reflex release of sympathetic vasoconstrictor tone in the skin of the extremities, causing a measurable temperature increase at the site of release. In the sympathetic release test, the…

  18. Blood histamine release: A new allergy blood test

    International Nuclear Information System (INIS)

    Faraj, B.A.; Gottlieb, G.R.; Camp, V.M.; Lollies, P.

    1985-01-01

    Allergen-mediated histamine release from human leukocytes represents an important model for in vitro studies of allergic reactions. The purpose of this study was to determine whether the measurement of histamine released in allergic patients (pts) by radioenzymatic assay following mixing of their blood with common allergens represents a reliable index for diagnosis of atopic allergy. Three categories of allergies were used: (1) housedust and mite; (2) cat and dog dander; (3) trees and grasses and ragweed mixture. The presence of allergy was established by intradermal skin testing in the study group of 82 pts. Significant atopy was defined as ≥ 3+ (overall range 0-4 +, negative to maximum) on skin testing. The test was carried out in tubes with 0.5 ml heparinized blood, 0.5 ml tris albumin buffer, and one of the allergens (60-100 PNU/ml). In 20 controls without allergy, there always was ≤ 4% histamine release (normal response). A significant allergen-mediated histamine release, ranging from 12 to 30% of the total blood histamine content, was observed in 96% of the pts with skin test sensitivity of ≥ 3+. There was good agreement between skin testing and histamine release in terms of the allergen causing the response. Thus, measurement of histamine release in blood in response to allergen challenge represents a clinically useful in vitro test for the diagnosis of atopic allergy. Because data can be obtained from a single sample and are highly quantitative, this new method should have application to the longitudinal study of allergic pts and to the assessment of interventions

  19. Savannah River release: test of the new ARAC capability

    International Nuclear Information System (INIS)

    Dickerson, M.H.

    1977-01-01

    Working jointly from opposite sides of the nation Lawrence Livermore Laboratory (LLL) and the Savannah River Laboratory (SRL) quickly assessed the consequences of an early-morning tritium release in May 1974 from the Savannah River Plant, in South Carolina. Measurements confirmed the accuracy of the LLL predictions. Due to the small quantity involved and to the release location (well within the plant confines), the release was not dangerous to the public. The emergency provided a dramatic test of procedures and capabilities of the new Atmospheric Release Advisory Capability (ARAC) center at Livermore, which was not yet operational, demonstrating the capacity for quick response, and the feasibility of real-time data acquisition and transmittal across the continent

  20. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  1. Development of novel diclofenac potassium controlled release tablets by wet granulation technique and the effect of co-excipients on in vitro drug release rates.

    Science.gov (United States)

    Shah, Shefaatullah; Khan, Gul Majid; Jan, Syed Umer; Shah, Kifayatullah; Hussain, Abid; Khan, Haroon; Khan, Haroon; Khan, Haroon; Khan, Kamran Ahmad

    2012-01-01

    The aim of the present study was the formulation and evaluation of controlled release polymeric tablets of Diclofenac Potassium by wet granulation method for the release rate, release pattern and the mechanism involved in drug release. Formulations having three grades of polymer Ethocel (7P; 7FP, 10P, 10FP, 100P, 100FP) in several drugs to polymer ratios (10:3 and 10:1) were compressed into tablets using wet granulation method. Co-excipients were added to some selected formulations to investigate their enhancement effect on in vitro drug release patterns. In vitro drug release studies were performed using USP Method-1 (Rotating Basket method) and Phosphate buffer (pH 7.4) was used as a dissolution medium. The similarities and dissimilarities of release profiles of test formulations with reference standard were checked using f2 similarity factor and f1 dissimilarity factor. Mathematical/Kinetic models were employed to determine the release mechanism and drug release kinetics.

  2. Determination of the sterile release rate for stopping growing age-structured populations

    International Nuclear Information System (INIS)

    Barclay, Hugh John

    2016-01-01

    A freely-growing age-structured population was modelled for growth and control by sterile male releases. Equilibrium populations yield critical sterile male release rates that would hold the population at equilibrium. It is shown here that these rates may be different from the release rates required to stop a growing population and bring it to an equilibrium. A computer simulation was constructed of this population and a parameter sensitivity analysis graphed the effects on the required sterile male release rate of fertility, mating delay in adult females, net juvenile survivorship, three adult survivorship curves, the time spent in the juvenile stages, and total life span. The adult survivorship curves had the greatest effect on the required sterile release rate for population elimination. The required release rate was also determined for Ceratitis capitata (Wiedemann) using survivorship and fertility data from a laboratory strain. The concepts of over-flooding ratio and release ratio were discussed and quantified for the cases above. (author)

  3. Applications of energy-release-rate techniques to part-through cracks in experimental pressure vessels

    International Nuclear Information System (INIS)

    Bass, B.R.; Bryan, R.H.; Bryson, J.W.; Merkle, J.G.

    1982-01-01

    In nonlinear applications of computational fracture mechanics, energy release rate techniques are used increasingly for computing stress intensity parameters of crack configurations. Recently, deLorenzi used the virtual-crack-extension method to derive an analytical expression for the energy release rate that is better suited for three-dimensional calculations than the well-known J-integral. Certain studies of fracture phenomena, such as pressurized-thermal-shock of cracked structures, require that crack tip parameters be determined for combined thermal and mechanical loads. A method is proposed here that modifies the isothermal formulation of deLorenzi to account for thermal strains in cracked bodies. This combined thermo-mechanical formulation of the energy release rate is valid for general fracture, including nonplanar fracture, and applies to thermo-elastic as well as deformation plasticity material models. Two applications of the technique are described here. In the first, semi-elliptical surface cracks in an experimental test vessel are analyzed under elastic-plastic conditions using the finite element method. The second application is a thick-walled test vessel subjected to combined pressure and thermal shock loadings

  4. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  5. Large-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.; Kurath, Dean E.; Adkins, Harold E.; Billing, Justin M.; Burns, Carolyn A.; Davis, James M.; Enderlin, Carl W.; Fischer, Christopher M.; Jenks, Jeromy WJ; Lukins, Craig D.; MacFarlan, Paul J.; Shutthanandan, Janani I.; Smith, Dennese M.

    2012-12-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  6. Study on the leak rate test for HANARO reactor building

    International Nuclear Information System (INIS)

    Choi, Y. S.; Kim, Y. K.; Kim, M. J.; Park, J. M.; Woo, J. S.

    2002-01-01

    The reactor building of HANARO adopts the confinement concept, which allows a certain amount of air leakage. In order to restrict the air leakage through the confinement boundary, negative pressure of at least 2.5 mmWG is maintained in normal operating condition while maintaining 25 mmWG of negative pressure in abnormal condition, the inside air filtered by a train of charcoal filter is released to the atmosphere through the stack. In this situation, if the emergency ventilation system is not operable, the reactor building is isolated from the outside then the trapped air inside will be leaked out through the building by ground release concept. As the leak rate may be affected by an effect of wind velocity outside the reactor building, the air tightness of confinement should be maintained to limit the leak rate below the allowable value. The local leak rate test method was used since the beginning of the commissioning until July 1999. However it has been pointed out as a defect that the method is so susceptible to the change of temperature and atmospheric pressure during testing. For more accurate leak rate testing, we have introduced a new test method. We have periodically carried out the new leak rate testing and the results indicate that the bad effect by the temperature and atmospheric pressure change is considerably reduced, which gives more stable leak rate measurement

  7. Fission product release measured during fuel damage tests at the Power Burst Facility

    International Nuclear Information System (INIS)

    Osetek, D.J.; Hartwell, J.K.; Vinjamuri, K.; Cronenberg, A.W.

    1985-01-01

    Results are presented of fission product release behavior observed during four severe fuel damage tests on bundles of UO 2 fuel rods. Transient temperatures up to fuel melting were obtained in the tests that included both rapid quench and slow cooldown, low and high (36 GWd/t) burnup fuel and the addition of Ag-In-Cd control rods. Release fractions of major fission product species and release rates of noble gas species are reported. Significant differences in release behavior are discussed between heatup and cooldown periods, low and high burnup fuel and long- and short-lived fission products. Explanations are offered for the probable reasons for the observed differences and recommendations for further studies are given

  8. FACTORS AFFECTING THE RELEASE RATE OF A HIGHLY SOLUBLE DRUG FROM A PROGRAMMED RELEASE MEGALOPOROUS SYSTEM

    NARCIS (Netherlands)

    VANDERVEEN, C; MENGER, NR; LERK, CF

    The present study reports on the successful incorporation of a highly soluble drug, procaine HCl, in a programmed-release megaloporous system. This solid two-phase system is composed of housing phase matrix granules (HMG), controlling liquid penetration into the system, and of restraining phase

  9. Inverse modelling of radionuclide release rates using gamma dose rate observations

    Science.gov (United States)

    Hamburger, Thomas; Evangeliou, Nikolaos; Stohl, Andreas; von Haustein, Christoph; Thummerer, Severin; Wallner, Christian

    2015-04-01

    Severe accidents in nuclear power plants such as the historical accident in Chernobyl 1986 or the more recent disaster in the Fukushima Dai-ichi nuclear power plant in 2011 have drastic impacts on the population and environment. Observations and dispersion modelling of the released radionuclides help to assess the regional impact of such nuclear accidents. Modelling the increase of regional radionuclide activity concentrations, which results from nuclear accidents, underlies a multiplicity of uncertainties. One of the most significant uncertainties is the estimation of the source term. That is, the time dependent quantification of the released spectrum of radionuclides during the course of the nuclear accident. The quantification of the source term may either remain uncertain (e.g. Chernobyl, Devell et al., 1995) or rely on estimates given by the operators of the nuclear power plant. Precise measurements are mostly missing due to practical limitations during the accident. The release rates of radionuclides at the accident site can be estimated using inverse modelling (Davoine and Bocquet, 2007). The accuracy of the method depends amongst others on the availability, reliability and the resolution in time and space of the used observations. Radionuclide activity concentrations are observed on a relatively sparse grid and the temporal resolution of available data may be low within the order of hours or a day. Gamma dose rates, on the other hand, are observed routinely on a much denser grid and higher temporal resolution and provide therefore a wider basis for inverse modelling (Saunier et al., 2013). We present a new inversion approach, which combines an atmospheric dispersion model and observations of radionuclide activity concentrations and gamma dose rates to obtain the source term of radionuclides. We use the Lagrangian particle dispersion model FLEXPART (Stohl et al., 1998; Stohl et al., 2005) to model the atmospheric transport of the released radionuclides. The

  10. Possibilities for in-vitro testing of controlled-release parenterals.

    OpenAIRE

    Kožák, Jan

    2014-01-01

    The objective of this study was to start with the development of a gel-based medium simulating intramuscular environment for in-vitro drug release testing as an alternative to currently used water-based media. A pork meat was selected as a model of the muscle tissue. At the first part of the study, diffusion rate was proposed as the most determining factor of drug release in gel-based medium. Consequently, the diffusion rate of sodium fluorescein in pork meat was compared with the diffusion r...

  11. Analysis of results of oral glucose tolerance test (OGTT) and insulin releasing test in hepatogenic diabetics

    International Nuclear Information System (INIS)

    He Haoming; Fu Qiang; Tian Xiaoping; Su Cainu

    2001-01-01

    Objective: To explore the clinical values of OGTT and insulin releasing test in hepatogenic diabetics. Method: OGTT was performed by enzymes method and insulin releasing test by RIA in 30 patients with hepatogenic diabetes, 31 cases with II diabetes and 35 controls. Results: During OGTT, blood glucose levels at various time were about the same in hepatogenic diabetics and II diabetics (P < 0.05), except at 180 min (P < 0.01). Basal hyperinsulinemia was present is hepatogenic diabetics. Conclusion: OGTT and insulin releasing test had a definite clinical value in the differential diagnosis of hepatogenic diabetics

  12. Heat and mass release for some transient fuel source fires: A test report

    International Nuclear Information System (INIS)

    Nowlen, S.P.

    1986-10-01

    Nine fire tests using five different trash fuel source packages were conducted by Sandia National Laboratories. This report presents the findings of these tests. Data reported includes heat and mass release rates, total heat and mass release, plume temperatures, and average fuel heat of combustion. These tests were conducted as a part of the US Nuclear Regulatory Commission sponsored fire safety research program. Data from these tests were intended for use in nuclear power plant probabilistic risk assessment fire analyses. The results were also used as input to a fire test program at Sandia investigating the vulnerability of electrical control cabinets to fire. The fuel packages tested were chosen to be representative of small to moderately sized transient trash fuel sources of the type that would be found in a nuclear power plant. The highest fire intensity encountered during these tests was 145 kW. Plume temperatures did not exceed 820 0 C

  13. FLECHT low flooding rate skewed test series data report

    International Nuclear Information System (INIS)

    Rosal, E.R.; Conway, C.E.; Krepinevich, M.C.

    1977-05-01

    The FLECHT Low Flooding Rate Tests were conducted in an improved original FLECHT Test Facility to provide heat transfer coefficient and entrainment data at forced flooding rates of 1 in./sec. and with electrically heated rod bundles which had cosine and top skewed axial power profiles. The top-skewed axial power profile test series has now been successfully completed and is here reported. For these tests the rod bundle was enclosed in a low mass cylindrical housing which would minimize the wall housing effects encountered in the cosine test series. These tests examined the effects of initial clad temperature, variable stepped and continuously variable flooding rates, housing heat release, rod peak power, constant low flooding rates, coolant subcooling, hot and cold channel entrainment, and bundle stored and generated power. Data obtained in runs which met the test specifications are reported here, and include rod clad temperatures, turn around and quench times, heat transfer coefficients, inlet flooding rates, overall mass balances, differential pressures and calculated void fractions in the test section, thimble wall and steam temperatures, and exhaust steam and liquid carryover rates

  14. Tritium transport calculations for the IFMIF Tritium Release Test Module

    Energy Technology Data Exchange (ETDEWEB)

    Freund, Jana, E-mail: jana.freund@kit.edu; Arbeiter, Frederik; Abou-Sena, Ali; Franza, Fabrizio; Kondo, Keitaro

    2014-10-15

    Highlights: • Delivery of material data for the tritium balance in the IFMIF Tritium Release Test Module. • Description of the topological models in TMAP and the adapted fusion-devoted Tritium Permeation Code (FUS-TPC). • Computation of release of tritium from the breeder solid material into the purge gas. • Computation of the loss of tritium over the capsule wall, rig hull, container wall and purge gas return line. - Abstract: The IFMIF Tritium Release Test Module (TRTM) is projected to measure online the tritium release from breeder ceramics and beryllium pebble beds under high energy neutron irradiation. Tritium produced in the pebble bed of TRTM is swept out continuously by a purge gas flow, but can also permeate into the module's metal structures, and can be lost by permeation to the environment. According analyses on the tritium inventory are performed to support IFMIF plant safety studies, and to support the experiment planning. This paper describes the necessary elements for calculation of the tritium transport in the Tritium Release Test Module as follows: (i) applied equations for the tritium balance, (ii) material data from literature and (iii) the topological models and the computation of the five different cases; namely release of tritium from the breeder solid material into the purge gas, loss of tritium over the capsule wall, rig hull, container wall and purge gas return line in detail. The problem of tritium transport in the TRTM has been studied and analyzed by the Tritium Migration Analysis Program (TMAP) and the adapted fusion-devoted Tritium Permeation Code (FUS-TPC). TMAP has been developed at INEEL and now exists in Version 7. FUS-TPC Code was written in MATLAB with the original purpose to study the tritium transport in Helium Cooled Lead Lithium (HCLL) blanket and in a later version the Helium Cooled Pebble Bed (HCPB) blanket by [6] (Franza, 2012). This code has been further modified to be applicable to the TRTM. Results from the

  15. Tritium transport calculations for the IFMIF Tritium Release Test Module

    International Nuclear Information System (INIS)

    Freund, Jana; Arbeiter, Frederik; Abou-Sena, Ali; Franza, Fabrizio; Kondo, Keitaro

    2014-01-01

    Highlights: • Delivery of material data for the tritium balance in the IFMIF Tritium Release Test Module. • Description of the topological models in TMAP and the adapted fusion-devoted Tritium Permeation Code (FUS-TPC). • Computation of release of tritium from the breeder solid material into the purge gas. • Computation of the loss of tritium over the capsule wall, rig hull, container wall and purge gas return line. - Abstract: The IFMIF Tritium Release Test Module (TRTM) is projected to measure online the tritium release from breeder ceramics and beryllium pebble beds under high energy neutron irradiation. Tritium produced in the pebble bed of TRTM is swept out continuously by a purge gas flow, but can also permeate into the module's metal structures, and can be lost by permeation to the environment. According analyses on the tritium inventory are performed to support IFMIF plant safety studies, and to support the experiment planning. This paper describes the necessary elements for calculation of the tritium transport in the Tritium Release Test Module as follows: (i) applied equations for the tritium balance, (ii) material data from literature and (iii) the topological models and the computation of the five different cases; namely release of tritium from the breeder solid material into the purge gas, loss of tritium over the capsule wall, rig hull, container wall and purge gas return line in detail. The problem of tritium transport in the TRTM has been studied and analyzed by the Tritium Migration Analysis Program (TMAP) and the adapted fusion-devoted Tritium Permeation Code (FUS-TPC). TMAP has been developed at INEEL and now exists in Version 7. FUS-TPC Code was written in MATLAB with the original purpose to study the tritium transport in Helium Cooled Lead Lithium (HCLL) blanket and in a later version the Helium Cooled Pebble Bed (HCPB) blanket by [6] (Franza, 2012). This code has been further modified to be applicable to the TRTM. Results from the

  16. Influence of ceramic dental crown coating substrate thickness ratio on strain energy release rate

    Science.gov (United States)

    Khasnulhadi, K.; Daud, R.; Mat, F.; Noor, S. N. F. M.; Basaruddin, K. S.; Sulaiman, M. H.

    2017-10-01

    This paper presents the analysis of coating substrate thickness ratio effect on the crown coating fracture behaviour. The bi-layer material is examined under four point bending with pre-crack at the bottom of the core material by using finite element. Three different coating thickness of core/substrate was tested which is 1:1, 1:2 and 2:1. The fracture parameters are analysed based on bilayer and homogenous elastic interaction. The result shows that the ratio thickness of core/veneer provided a significant effect on energy release rate.

  17. Constant displacement rate testing at elevated temperatures

    International Nuclear Information System (INIS)

    Pepe, J.J.; Gonyea, D.C.

    1989-01-01

    A short time test has been developed which is capable of determining the long time notch sensitivity tendencies of CrMoV rotor forging materials. This test is based on Constant Displacement Rate (CDR) testing of a specific notch bar specimen at 1200 0 F at 2 mils/in/hour displacement rate. These data were correlated to conventional smooth and notch bar rupture behavior for a series of CrMoV materials with varying long time ductility tendencies. The purpose of this paper is to describe the details of this new test procedure and some of the relevant mechanics of material information generated during its development

  18. Measurement of semiochemical release rates with a dedicated environmental control system

    Science.gov (United States)

    Heping Zhu; Harold W. Thistle; Christopher M. Ranger; Hongping Zhou; Brian L. Strom

    2015-01-01

    Insect semiochemical dispensers are commonly deployed under variable environmental conditions over a specified period. Predictions of their longevity are hampered by a lack of methods to accurately monitor and predict how primary variables affect semiochemical release rate. A system was constructed to precisely determine semiochemical release rates under...

  19. Development of polymer film dosage forms of lidocaine for buccal administration. I. Penetration rate and release rate.

    Science.gov (United States)

    Okamoto, H; Taguchi, H; Iida, K; Danjo, K

    2001-12-13

    We examined the penetration rate of lidocaine (LC) through excised oral mucosa from hamster cheek pouch and the in vitro release rate of LC from film dosage forms with hydroxypropylcellulose (HPC) as a film base. Addition of glycyrrhizic acid (GL) to the HPC films increased the LC release rate almost GL-content-dependently, while an optimum GL content was observed for the LC penetration rate. No LC penetration was observed from an acidic aqueous solution (pH 3.4) of LC, suggesting only unionized LC can substantially penetrate through the mucosa. A significant relationship between the penetration rate of LC and the release rate of unionized LC was found, suggesting that the in vitro dissolution study is a useful tool to predict the penetration rate taking the unionized drug fraction into consideration.

  20. ASSESSMENT OF RELEASE RATES FOR RADIONUCLIDES IN ACTIVATED CONCRETE.

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN,T.M.

    2003-08-23

    The Maine Yankee (MY) nuclear power plant is undergoing the process of decontamination and decommissioning (D&D). Part of the process requires analyses that demonstrate that any radioactivity that remains after D&D will not cause exposure to radioactive contaminants to exceed acceptable limits. This requires knowledge of the distribution of radionuclides in the remaining material and their potential release mechanisms from the material to the contacting groundwater. In this study the concern involves radionuclide contamination in activated concrete in the ICI Sump below the containment building. Figures 1-3 are schematic representations of the ICI Sump. Figure 2 and 3 contain the relevant dimensions needed for the analysis. The key features of Figures 2 and 3 are the 3/8-inch carbon steel liner that isolates the activated concrete from the pit and the concrete wall, which is between 7 feet and 7 feet 2 inches thick. During operations, a small neutron flux from the reactor activated the carbon steel liner and the concrete outside the liner. Current MY plans call for filling the ICI sump with compacted sand.

  1. Auditing HIV Testing Rates across Europe

    DEFF Research Database (Denmark)

    Raben, D; Mocroft, A; Rayment, M

    2015-01-01

    European guidelines recommend the routine offer of an HIV test in patients with a number of AIDS-defining and non-AIDS conditions believed to share an association with HIV; so called indicator conditions (IC). Adherence with this guidance across Europe is not known. We audited HIV testing behaviour...... audits from 23 centres, representing 7037 patients. The median test rate across audits was 72% (IQR 32-97), lowest in Northern Europe (median 44%, IQR 22-68%) and highest in Eastern Europe (median 99%, IQR 86-100). Uptake of testing was close to 100% in all regions. The median HIV+ rate was 0.9% (IQR 0.......0-4.9), with 29 audits (60.4%) having an HIV+ rate >0.1%. After adjustment, there were no differences between regions of Europe in the proportion with >0.1% testing positive (global p = 0.14). A total of 113 patients tested HIV+. Applying the observed rates of testing HIV+ within individual ICs and regions to all...

  2. Static and dynamic strain energy release rates in toughened thermosetting composite laminates

    Science.gov (United States)

    Cairns, Douglas S.

    1992-01-01

    In this work, the static and dynamic fracture properties of several thermosetting resin based composite laminates are presented. Two classes of materials are explored. These are homogeneous, thermosetting resins and toughened, multi-phase, thermosetting resin systems. Multi-phase resin materials have shown enhancement over homogenous materials with respect to damage resistance. The development of new dynamic tests are presented for composite laminates based on Width Tapered Double Cantilevered Beam (WTDCB) for Mode 1 fracture and the End Notched Flexure (ENF) specimen. The WTDCB sample was loaded via a low inertia, pneumatic cylinder to produce rapid cross-head displacements. A high rate, piezo-electric load cell and an accelerometer were mounted on the specimen. A digital oscilloscope was used for data acquisition. Typical static and dynamic load versus displacement plots are presented. The ENF specimen was impacted in three point bending with an instrumented impact tower. Fracture initiation and propagation energies under static and dynamic conditions were determined analytically and experimentally. The test results for Mode 1 fracture are relatively insensitive to strain rate effects for the laminates tested in this study. The test results from Mode 2 fracture indicate that the toughened systems provide superior fracture initiation and higher resistance to propagation under dynamic conditions. While the static fracture properties of the homogeneous systems may be relatively high, the apparent Mode 2 dynamic critical strain energy release rate drops significantly. The results indicate that static Mode 2 fracture testing is inadequate for determining the fracture performance of composite structures subjected to conditions such as low velocity impact. A good correlation between the basic Mode 2 dynamic fracture properties and the performance is a combined material/structural Compression After Impact (CAI) test is found. These results underscore the importance of

  3. In situ release rates of Cu and Zn from commercial antifouling paints at different salinities.

    Science.gov (United States)

    Lagerström, Maria; Lindgren, J Fredrik; Holmqvist, Albin; Dahlström, Mia; Ytreberg, Erik

    2018-02-01

    Antifouling paints are environmentally risk assessed based on their biocidal release rates to the water phase. In situ release rates of copper (Cu) and zinc (Zn) were derived for five commercial paints in two recreational marinas with different salinities (5 and 14 PSU) using an X-Ray Fluorescence spectrometer (XRF). Salinity was found to significantly affect the Cu release, with twice the amount of Cu released at the higher salinity, while its influence on the Zn release was paint-specific. Site-specific release rates for water bodies with salinity gradients, e.g. the Baltic Sea, are therefore necessary for more realistic risk assessments of antifouling paints. Furthermore, the in situ release rates were up to 8 times higher than those generated using standardized laboratory or calculation methods. The environmental risk assessment repeated with the field release rates concludes that it is questionable whether the studied products should be allowed on the Swedish market. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Evaluation of olibanum and its resin as rate controlling matrix for controlled release of diclofenac

    OpenAIRE

    Chowdary KPR; Mohapatra P; Murali Krishna M

    2006-01-01

    Olibanum and its resin and carbohydrate fractions were evaluated as rate controlling matrix materials in tablets for controlled release of diclofenac. Diclofenac matrix tablets were formulated employing olibanum and its resin and carbohydrate fractions in different concentrations and the tablets were evaluated for various tablet characters including drug release kinetics and mechanism. Olibanum and its resin component exhibited excellent retarding effect on drug release from the matrix tablet...

  5. Testing jumps via false discovery rate control.

    Science.gov (United States)

    Yen, Yu-Min

    2013-01-01

    Many recently developed nonparametric jump tests can be viewed as multiple hypothesis testing problems. For such multiple hypothesis tests, it is well known that controlling type I error often makes a large proportion of erroneous rejections, and such situation becomes even worse when the jump occurrence is a rare event. To obtain more reliable results, we aim to control the false discovery rate (FDR), an efficient compound error measure for erroneous rejections in multiple testing problems. We perform the test via the Barndorff-Nielsen and Shephard (BNS) test statistic, and control the FDR with the Benjamini and Hochberg (BH) procedure. We provide asymptotic results for the FDR control. From simulations, we examine relevant theoretical results and demonstrate the advantages of controlling the FDR. The hybrid approach is then applied to empirical analysis on two benchmark stock indices with high frequency data.

  6. Testing jumps via false discovery rate control.

    Directory of Open Access Journals (Sweden)

    Yu-Min Yen

    Full Text Available Many recently developed nonparametric jump tests can be viewed as multiple hypothesis testing problems. For such multiple hypothesis tests, it is well known that controlling type I error often makes a large proportion of erroneous rejections, and such situation becomes even worse when the jump occurrence is a rare event. To obtain more reliable results, we aim to control the false discovery rate (FDR, an efficient compound error measure for erroneous rejections in multiple testing problems. We perform the test via the Barndorff-Nielsen and Shephard (BNS test statistic, and control the FDR with the Benjamini and Hochberg (BH procedure. We provide asymptotic results for the FDR control. From simulations, we examine relevant theoretical results and demonstrate the advantages of controlling the FDR. The hybrid approach is then applied to empirical analysis on two benchmark stock indices with high frequency data.

  7. Hindered disulfide bonds to regulate release rate of model drug from mesoporous silica.

    Science.gov (United States)

    Nadrah, Peter; Maver, Uroš; Jemec, Anita; Tišler, Tatjana; Bele, Marjan; Dražić, Goran; Benčina, Mojca; Pintar, Albin; Planinšek, Odon; Gaberšček, Miran

    2013-05-01

    With the advancement of drug delivery systems based on mesoporous silica nanoparticles (MSNs), a simple and efficient method regulating the drug release kinetics is needed. We developed redox-responsive release systems with three levels of hindrance around the disulfide bond. A model drug (rhodamine B dye) was loaded into MSNs' mesoporous voids. The pore opening was capped with β-cyclodextrin in order to prevent leakage of drug. Indeed, in absence of a reducing agent the systems exhibited little leakage, while the addition of dithiothreitol cleaved the disulfide bonds and enabled the release of cargo. The release rate and the amount of released dye were tuned by the level of hindrance around disulfide bonds, with the increased hindrance causing a decrease in the release rate as well as in the amount of released drug. Thus, we demonstrated the ability of the present mesoporous systems to intrinsically control the release rate and the amount of the released cargo by only minor structural variations. Furthermore, an in vivo experiment on zebrafish confirmed that the present model delivery system is nonteratogenic.

  8. Leak rate test of containment personnel lock

    International Nuclear Information System (INIS)

    Julien, J.T.; Peters, S.W.

    1988-01-01

    As part of the US NRC Containment Integrity Program, a leak rate test was performed on a full size personnel airlock for a nuclear containment building. The airlock was subjected to conditions simulating severe accident conditions. The objective of the test was to characterize the performance of airlock door seals when subjected to conditions that exceeded design. The seals tested were a double dog-ear configuration and made from EPDM E603. The data obtained from this test will be used by SNL as a benchmark for development of analytical methods. In addition to leak rate information, strain, temperature, displacements, and pressure data were measured and recorded from over 330 transducers. The test lasted approximately 60 hours. Data were recorded at regular intervals and during heating, pressurization and depressurization. The inner airlock door and bulkhead were exposed to a maximum air temperature of 850 F and a maximum air pressure of 300 psig. The airlock was originally designed for 340 F and 60 psig. Two heating and pressurization cycles were planned; one to heat to 400 F and pressurize to 300 psig, and the second to heat to 800 F and pressurize to 300 psig. No significant leakage was recorded during these two cycles. A third cycle was added to the test program. The air temperature was increased to 850 F and held at this temperature for approximately 10 hours. The inner door seal failed quickly at a pressure of 150.5 psig. The maximum leak rate was 706 SCFM

  9. An atomistic methodology of energy release rate for graphene at nanoscale

    International Nuclear Information System (INIS)

    Zhang, Zhen; Lee, James D.; Wang, Xianqiao

    2014-01-01

    Graphene is a single layer of carbon atoms packed into a honeycomb architecture, serving as a fundamental building block for electric devices. Understanding the fracture mechanism of graphene under various conditions is crucial for tailoring the electrical and mechanical properties of graphene-based devices at atomic scale. Although most of the fracture mechanics concepts, such as stress intensity factors, are not applicable in molecular dynamics simulation, energy release rate still remains to be a feasible and crucial physical quantity to characterize the fracture mechanical property of materials at nanoscale. This work introduces an atomistic simulation methodology, based on the energy release rate, as a tool to unveil the fracture mechanism of graphene at nanoscale. This methodology can be easily extended to any atomistic material system. We have investigated both opening mode and mixed mode at different temperatures. Simulation results show that the critical energy release rate of graphene is independent of initial crack length at low temperature. Graphene with inclined pre-crack possesses higher fracture strength and fracture deformation but smaller critical energy release rate compared with the graphene with vertical pre-crack. Owing to its anisotropy, graphene with armchair chirality always has greater critical energy release rate than graphene with zigzag chirality. The increase of temperature leads to the reduction of fracture strength, fracture deformation, and the critical energy release rate of graphene. Also, higher temperature brings higher randomness of energy release rate of graphene under a variety of predefined crack lengths. The energy release rate is independent of the strain rate as long as the strain rate is small enough

  10. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  11. Accelerated dissolution testing for controlled release microspheres using the flow-through dissolution apparatus.

    Science.gov (United States)

    Collier, Jarrod W; Thakare, Mohan; Garner, Solomon T; Israel, Bridg'ette; Ahmed, Hisham; Granade, Saundra; Strong, Deborah L; Price, James C; Capomacchia, A C

    2009-01-01

    Theophylline controlled release capsules (THEO-24 CR) were used as a model system to evaluate accelerated dissolution tests for process and quality control and formulation development of controlled release formulations. Dissolution test acceleration was provided by increasing temperature, pH, flow rate, or adding surfactant. Electron microscope studies on the theophylline microspheres subsequent to each experiment showed that at pH values of 6.6 and 7.6 the microspheres remained intact, but at pH 8.6 they showed deterioration. As temperature was increased from 37-57 degrees C, no change in microsphere integrity was noted. Increased flow rate also showed no detrimental effect on integrity. The effect of increased temperature was determined to be the statistically significant variable.

  12. Airborne release fractions/rates and respirable fractions for nonreactor nuclear facilities. Volume 2, Appendices

    International Nuclear Information System (INIS)

    1994-12-01

    This document contains compiled data from the DOE Handbook on Airborne Release Fractions/Rates and Respirable Fractions for Nonreactor Nuclear facilities. Source data and example facilities utilized, such as the Plutonium Recovery Facility, are included

  13. Applied field test procedures on petroleum release sites

    International Nuclear Information System (INIS)

    Gilbert, G.; Nichols, L.

    1995-01-01

    The effective remediation of petroleum contaminated soils and ground water is a significant issue for Williams Pipe Line Co. (Williams): costing $6.8 million in 1994. It is in the best interest, then, for Williams to adopt approaches and apply technologies that will be both cost-effective and comply with regulations. Williams has found the use of soil vapor extraction (SVE) and air sparging (AS) field test procedures at the onset of a petroleum release investigation/remediation accomplish these goals. This paper focuses on the application of AS/SVE as the preferred technology to a specific type of remediation: refined petroleum products. In situ field tests are used prior to designing a full-scale remedial system to first validate or disprove initial assumptions on applicability of the technology. During the field test, remedial system design parameters are also collected to tailor the design and operation of a full-scale system to site specific conditions: minimizing cost and optimizing effectiveness. In situ field tests should be designed and operated to simulate as close as possible the operation of a full-scale remedial system. The procedures of an in situ field test will be presented. The results of numerous field tests and the associated costs will also be evaluated and compared to full-scale remedial systems and total project costs to demonstrate overall effectiveness. There are many advantages of As/SVE technologies over conventional fluid extraction or SVE systems alone. However, the primary advantage is the ability to simultaneously reduce volatile and biodegradable compound concentrations in the phreatic, capillary fringe, and unsaturated zones

  14. Humidity Testing for Human Rated Spacecraft

    Science.gov (United States)

    Johnson, Gary B.

    2009-01-01

    Determination that equipment can operate in and survive exposure to the humidity environments unique to human rated spacecraft presents widely varying challenges. Equipment may need to operate in habitable volumes where the atmosphere contains perspiration, exhalation, and residual moisture. Equipment located outside the pressurized volumes may be exposed to repetitive diurnal cycles that may result in moisture absorption and/or condensation. Equipment may be thermally affected by conduction to coldplate or structure, by forced or ambient air convection (hot/cold or wet/dry), or by radiation to space through windows or hatches. The equipment s on/off state also contributes to the equipment s susceptibility to humidity. Like-equipment is sometimes used in more than one location and under varying operational modes. Due to these challenges, developing a test scenario that bounds all physical, environmental and operational modes for both pressurized and unpressurized volumes requires an integrated assessment to determine the "worst-case combined conditions." Such an assessment was performed for the Constellation program, considering all of the aforementioned variables; and a test profile was developed based on approximately 300 variable combinations. The test profile has been vetted by several subject matter experts and partially validated by testing. Final testing to determine the efficacy of the test profile on actual space hardware is in the planning stages. When validation is completed, the test profile will be formally incorporated into NASA document CxP 30036, "Constellation Environmental Qualification and Acceptance Testing Requirements (CEQATR)."

  15. Zero-Release Mixed Waste Process Facility Design and Testing

    International Nuclear Information System (INIS)

    Richard D. Boardman; John A. Deldebbio; Robert J. Kirkham; Martin K. Clemens; Robert Geosits; Ping Wan

    2004-01-01

    A zero-release off-gas cleaning system for mixed-waste thermal treatment processes has been evaluated through experimental scoping tests and process modeling. The principles can possibly be adapted to a fluidized-bed calcination or stream reforming process, a waste melter, a rotary kiln process, and possibly other waste treatment thermal processes. The basic concept of a zero-release off-gas cleaning system is to recycle the bulk of the off-gas stream to the thermal treatment process. A slip stream is taken off the off-gas recycle to separate and purge benign constituents that may build up in the gas, such as water vapor, argon, nitrogen, and CO2. Contaminants are separated from the slip stream and returned to the thermal unit for eventual destruction or incorporation into the waste immobilization media. In the current study, a standard packed-bed scrubber, followed by gas separation membranes, is proposed for removal of contaminants from the off-gas recycle slipstream. The scrub solution is continuously regenerated by cooling and precipitating sulfate, nitrate, and other salts that reach a solubility limit in the scrub solution. Mercury is also separated by the scrubber. A miscible chemical oxidizing agent was shown to effectively oxidize mercury and also NO, thus increasing their removal efficiency. The current study indicates that the proposed process is a viable option for reducing off-gas emissions. Consideration of the proposed closed-system off-gas cleaning loop is warranted when emissions limits are stringent, or when a reduction in the total gas emissions volume is desired. Although the current closed-loop appears to be technically feasible, economical considerations must be also be evaluated on a case-by-case basis

  16. The Influence of Polyethylene Glycol Solution on the Dissolution Rate of Sustained Release Morphine.

    Science.gov (United States)

    Hodgman, Michael; Holland, Michael G; Englich, Ulrich; Wojcik, Susan M; Grant, William D; Leitner, Erich

    2016-12-01

    Whole bowel irrigation (WBI) is a management option for overdose of medications poorly adsorbed to activated charcoal, with modified release properties, or for body packers. Polyethylene glycol (PEG) is a mixture of ethylene oxide polymers of varying molecular weight. PEG with an average molecular weight of 3350 g/mol is used for WBI. PEG electrolyte lavage solution has been shown in vitro to hasten the dissolution of acetaminophen. The impact of PEG on the pharmacokinetics of extended release pharmaceuticals is unknown. Lower average molecular weight PEG mixtures are used as solvents and excipients. We sought to investigate the impact of PEG on the release of morphine from several extended release morphine formulations. An in vitro gastric model was developed. To test the validity of our model, we first investigated the previously described interaction of ethanol and Avinza®. Once demonstrated, we then investigated the effect of PEG with several extended release morphine formulations. In the validation portion of our study, we confirmed an ethanol Avinza® interaction. Subsequently, we did not observe accelerated release of morphine from Avinza® or generic extended release morphine in the presence of PEG. The use of PEG for gastric decontamination following ingestion of these extended release morphine formulations is unlikely to accelerate morphine release and aggravate intoxication.

  17. An interferon-gamma release assay test performs well in routine screening for tuberculosis

    DEFF Research Database (Denmark)

    Vestergaard Danielsen, Allan; Fløe, Andreas; Lillebæk, Troels

    2014-01-01

    Introduction: A positive interferon-gamma release assay (IGRA) is regarded as proof of latent Mycobacterium tuberculosis infection. We conducted an evaluation of the IGRA test “T-SPOT.TB” to test its performance during clinical routine use by analysing the positivity rate and odds, effect of season...... and sensitivity. Material and methods: Data from T-SPOT.TB testing together with age and test indications (anti-tumour necrosis factor alpha (TNFα) candidate, contact investigation or suspicion of tuberculosis (TB)) were combined with mycobac­teria culture results. Results: A total of 1,809 patients were tested....... Conclusive results were achieved for 1,780 patients (98.4%). Among these, 4.6% of anti-TNFα candidates, 19.3% of contacts and 24.4% of TB suspects tested positive. Compared with anti-TNFα candidates, the odds for a positive result were significantly higher for contact investigations (odds ratio (OR), mean...

  18. Preliminary calculations of release rates from spent fuel in a tuff repository

    International Nuclear Information System (INIS)

    Apted, M.J.; O'Connell, W.J.; Lee, K.H.; MacIntyre, A.T.; Ueng, T.S.; Pigford, T.H.; Lee, W.W.L.

    1991-01-01

    Time-dependent release rates of Tc-99, I-129, Cs-135, and Np-237 have been calculated for wet-drip and moist-continuous release modes from the engineered barrier system of a potential nuclear waste repository in unsaturated tuff, representative of a possible repository at Yucca Mountain in southern Nevada. We describe the modes of water contact and of release of dissolved radionuclides to the surrounding intact rock, and the corresponding calculational models. We list the parameter values adopted, and then present numerical results, conclusions, and recommendations. 21 refs., 5 figs., 2 tabs

  19. Controlled release of free-falling test models

    Science.gov (United States)

    Fife, W. J.; Holway, H. P.

    1970-01-01

    Releasing device, powered by a drill motor through an adjustable speed reducer, has a spinning release head with three retractable spring-loaded fingers. The fingers are retracted by manual triggering of a cable at the motor end of the unit.

  20. Development and evaluation of accelerated drug release testing methods for a matrix-type intravaginal ring.

    Science.gov (United States)

    Externbrink, Anna; Eggenreich, Karin; Eder, Simone; Mohr, Stefan; Nickisch, Klaus; Klein, Sandra

    2017-01-01

    Accelerated drug release testing is a valuable quality control tool for long-acting non-oral extended release formulations. Currently, several intravaginal ring candidates designed for the long-term delivery of steroids or anti-infective drugs are being in the developing pipeline. The present article addresses the demand for accelerated drug release methods for these formulations. We describe the development and evaluation of accelerated release methods for a steroid releasing matrix-type intravaginal ring. The drug release properties of the formulation were evaluated under real-time and accelerated test conditions. Under real-time test conditions drug release from the intravaginal ring was strongly affected by the steroid solubility in the release medium. Under sufficient sink conditions that were provided in release media containing surfactants drug release was Fickian diffusion driven. Both temperature and hydro-organic dissolution media were successfully employed to accelerate drug release from the formulation. Drug release could be further increased by combining the temperature effect with the application of a hydro-organic release medium. The formulation continued to exhibit a diffusion controlled release kinetic under the investigated accelerated conditions. Moreover, the accelerated methods were able to differentiate between different prototypes of the intravaginal ring that exhibited different release profiles under real-time test conditions. Overall, the results of the present study indicate that both temperature and hydro-organic release media are valid parameters for accelerating drug release from the intravaginal ring. Variation of either a single or both parameters yielded release profiles that correlated well with real-time release. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Review of tellurium release rates from LWR fuel elements under accident conditions

    International Nuclear Information System (INIS)

    Lorenz, R.A.; Beahm, E.C.; Wichner, R.P.

    1983-01-01

    Although fission product tellurium presents a potentially significant radiohazard, its release and transport in source-term experiments is frequently overlooked because it does not possess a readily measurable, gamma emission; moreover, a recent study emphasized noble gas, iodine and cesium release from LWR fuel elements because of the large data base that exists for these materials. Some new tests show that in some cases tellurium may be held up in core material to a greater degree than previously assumed - an observation that prompts a careful reappraisal of the existing tellurium-release data and its chemical foundation

  2. Calcium release rates from tooth enamel treated with dentifrices containing whitening agents and abrasives.

    Science.gov (United States)

    Araujo, Danilo Barral; Silva, Luciana Rodrigues; de Araujo, Roberto Paulo Correia

    2010-01-01

    Tooth whitening agents containing hydrogen peroxide and carbamide peroxide are used frequently in esthetic dental procedures. However, lesions on the enamel surface have been attributed to the action of these products. Using conventional procedures for separating and isolating biological structures, powdered enamel was obtained and treated with hydrogen peroxide, carbamide peroxide, and sodium bicarbonate, ingredients typically found in dentifrices. The enamel was exposed to different pH levels, and atomic emission spectrometry was used to determine calcium release rates. As the pH level increased, the rate of calcium release from enamel treated with dentifrices containing whitening agents decreased. Carbamide peroxide produced the lowest amount of decalcification, while sodium bicarbonate produced the highest release rates at all pH levels.

  3. Influence of Strain Rate on Heat Release under Quasi-Static Stretching of Metals. Experiment

    Science.gov (United States)

    Zimin, B. A.; Sventitskaya, V. E.; Smirnov, I. V.; Sud'enkov, Yu. V.

    2018-04-01

    The paper presents the results of experimental studies of energy dissipation during a quasi-static stretching of metals and alloys at room temperature. The strain rates varied in the range of 10-3-10-2 s-1. Samples of M1 copper, AZ31B magnesium alloy, BT6 titanium, 12Cr18Ni10Ti steel, and D16AM aluminum alloy were analyzed. The experimental results demonstrated a significant dependence of the heat release on the strain rate in the absence of its influence on stress-strain diagrams for all the metals studied in this range of strain rates. The correlation of the changes in the character of heat release with the processes of structural transformations at various stages of plastic flow is shown on the qualitative level. A difference in the nature of the processes of heat release in materials with different ratios of the plasticity and strength is noted.

  4. Radionuclide release rate inversion of nuclear accidents in nuclear facility based on Kalman filter

    International Nuclear Information System (INIS)

    Tang Xiuhuan; Bao Lihong; Li Hua; Wan Junsheng

    2014-01-01

    The rapidly and continually back-calculating source term is important for nuclear emergency response. The Gaussian multi-puff atmospheric dispersion model was used to produce regional environment monitoring data virtually, and then a Kalman filter was designed to inverse radionuclide release rate of nuclear accidents in nuclear facility and the release rate tracking in real time was achieved. The results show that the Kalman filter combined with Gaussian multi-puff atmospheric dispersion model can successfully track the virtually stable, linear or nonlinear release rate after being iterated about 10 times. The standard error of inversion results increases with the true value. Meanwhile extended Kalman filter cannot inverse the height parameter of accident release as interceptive error is too large to converge. Kalman filter constructed from environment monitoring data and Gaussian multi-puff atmospheric dispersion model can be applied to source inversion in nuclear accident which is characterized by static height and position, short and continual release in nuclear facility. Hence it turns out to be an alternative source inversion method in nuclear emergency response. (authors)

  5. 26 CFR 1.1274-4 - Test rate.

    Science.gov (United States)

    2010-04-01

    ... applicable Federal rate for the debt instrument is a foreign currency rate of interest that is analogous to... test rate of interest—(1) In general—(i) Test rate is the 3-month rate. Except as provided in paragraph (a)(2) of this section, the test rate of interest for a debt instrument issued in consideration for...

  6. Effect of rearing diet on the infection rate in flies released for the control of tsetse populations by sterile males

    International Nuclear Information System (INIS)

    Maudlin, I.

    1990-01-01

    In areas where sleeping sickness is endemic, it is the practice of sterile insect technique (SIT) programmes to give sterilized males a bloodmeal before release into the wild in order to reduce the risk of these released flies acting as disease vectors. This strategy has been adopted because of experimental evidence which showed that it was essential to infect flies at their first feed to establish a Tripanosoma brucei gambiense or T. b rhodesiense infection in tsetse flies. The aim of the work was to test artificial tsetse diets produced in the IAEA Laboratory at Seibersdorf in order to determine whether they were as effective as whole blood in inhibiting T. brucei sensu lato (sl) infections in flies. Seven artificial diets were tested with T.b. rhodesiense; Glossina morsitans morsitans males were fed one meal of the diet and then starved for 3 days before the infective feed. None of these diets significantly altered the infection rate of the treated flies and the seven groups produced statistically homogeneous results, with a mean midgut rate of 16% (control flies fed pig blood: 17%). Flies infected as tenerals with the same trypanosome stock produced midgut rates of 61%. Three of the diets were also tested with a T. congolense stock. There were no significant differences between flies fed artificial (mean midgut infection rate: 15%) and whole blood diets (19%). G. m. morsitans infected as tenerals with this trypanosome stock produced midgut rates of 66%. As with T. brucei sl infections, teneral flies were far more likely to develop a T. congolense infection than fed flies; this result suggests that all the tsetse flies used in SIT programmes should be fed before release in order to reduce the risk both to man and his livestock. Artificial diets are as effective as whole blood in inhibiting trypanosome infections. The effect of bloodmeal on the fly infection rates is discussed in relation to lectin production in fed flies. (author). 13 refs, 2 tabs

  7. Tritium breeding and release-rate kinetics from neutron-irradiated lithium oxide

    International Nuclear Information System (INIS)

    Quanci, J.F.

    1989-01-01

    The research encompasses the measurement of the tritium breeding and release-rate kinetics from lithium oxide, a ceramic tritium-breeding material. A thermal extraction apparatus which allows the accurate measurement of the total tritium inventory and release rate from lithium oxide samples under different temperatures, pressures and carrier-gas compositions with an uncertainty not exceeding 3% was developed. The goal of the Lithium Blanket Module program was to determine if advanced computer codes could accurately predict the tritium production in the lithium oxide blanket of a fusion power plant. A fusion blanket module prototype, was built and irradiated with a deuterium-tritium fusion-neutron source. The tritium production throughout the module was modeled with the MCNP three dimensional Monte Carlo code and was compared to the assay of the tritium bred in the module. The MCNP code accurately predicted tritium-breeding trends but underestimated the overall tritium breeding by 30%. The release rate of tritium from small grain polycrystalline sintered lithium oxide with a helium carrier gas from 300 to 450 C was found to be controlled by the first order surface desorption of mono-tritiated water. When small amounts of hydrogen were added to the helium carrier gas, the first order rate constant increased from the isotopic exchange of hydrogen for tritium at the lithium oxide surface occurring in parallel with the first order desorption process. The isotopic-exchange first order rate constant temperature dependence and hydrogen partial pressure dependence were evaluated. Large single crystals of lithium oxide were fabricated by the vacuum fusion technique. The release rate of tritium from the large single crystals was found to be controlled by diffusion, and the mixed diffusion-desorption controlled release regime

  8. Research on release rate of volatile organic compounds in typical vessel cabin

    Directory of Open Access Journals (Sweden)

    ZHANG Jinlan

    2018-02-01

    Full Text Available [Objectives] Volatile Organic Compounds (VOC should be efficiently controlled in vessel cabins to ensure the crew's health and navigation safety. As an important parameter, research on release rate of VOCs in cabins is required. [Methods] This paper develops a method to investigate this parameter of a ship's cabin based on methods used in other closed indoor environments. A typical vessel cabin is sampled with Tenax TA tubes and analyzed by Automated Thermal Desorption-Gas Chromatography-Mass Spectrometry (ATD-GC/MS. The lumped mode is used and the release rate of Benzene, Toluene, Ethylbenzene and Xylene (BTEX, the typical representatives of VOCs, is obtained both in closed and ventilated conditions. [Results] The results show that the content of xylene and Total Volatile Organic Compounds (TVOC exceed the indoor environment standards in ventilated conditions. The BTEX release rate is similar in both conditions except for the benzene. [Conclusions] This research builds a method to measure the release rate of VOCs, providing references for pollution character evaluation and ventilation and purification system design.

  9. Release rates of Al from inorganic and organic compounds in a sandy podzol, during laboratory experiments

    NARCIS (Netherlands)

    Salm, van der C.; Westerveld, J.W.; Verstraten, J.M.

    2000-01-01

    Research with respect to release rates of Al and Al concentrations in the soil solution has led to two contrasting hypotheses, stressing either the importance of kinetically constrained dissolution reactions or the role of complexation of Al to soil organic matter. The existence of two contrasting

  10. On the energy release rate in a turbulent current sheet on the Sun

    International Nuclear Information System (INIS)

    Bardakov, V.M.

    1986-01-01

    It is shown that turbulent current sheets on the Sun, realizing in the form of the Parker - Sweet flow, are in quasilinear regime of turbulence (or in the regime of instability threshold). The energy release rate in such sheets does not exceed 10 26 erg/s for typical plasma parameters in active regions

  11. [Studies on preparation and dissolution test in vitro of sustained-release dropping pills of curcumin].

    Science.gov (United States)

    Fang, Yu; Xiang, Bai; Pan, Zhen-Hua; Cao, De-Ying

    2010-01-01

    To study the prescription and technique of sustained-release dropping pills of curcumin and inspect their release property in vitro. The orthogonal test was used to screen the prescription and technique which were definited with the colligation evaluation of release and formation of dropping pills. The optimization of prescription and technique were as follows: stearic acid 70 mg, glycery monostearate 25 mg, solutol 6 mg, viscosity of cooling liquid was 100 mm2/s; the temperature of material liquid was 80 degrees C; the cooling temperature was 30 - 0 degrees C; the dropping speed was (21 +/- 2) dripping/min. The release behavior of sustained-release dropping pills of curcumin coincidented with Higuchi equation well and the character of sustained-release was transparent. The sustained-release dropping pills of curcumin have good property of sustained-release in vitro and their release behavior in vivo need to be inspected.

  12. 21 CFR 610.1 - Tests prior to release required for each lot.

    Science.gov (United States)

    2010-04-01

    ....1 Section 610.1 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... release required for each lot. No lot of any licensed product shall be released by the manufacturer prior... considered in determining whether or not the test results meet the test objective, except that a test result...

  13. Translational and extensional energy release rates (the J- and M-integrals) for a crack layer in thermoelasticity

    Science.gov (United States)

    Chudnovsky, A.; Gommerstadt, B.

    1985-01-01

    A number of papers have been presented on the evaluation of energy release rate for thermoelasticity and corresponding J integral. Two main approaches were developed to treat energy release rate in elasticity. The first is based on direct calculation of the potential energy rate with respect to crack length. The second makes use of Lagrangian formalism. The translational and expansional energy release rates in thermoelasticity are studied by employing the formalism of irreversible thermodynamics and the Crack Layer Approach.

  14. Electron transfer rates and energy releases during denitrification of municipal wastewater

    DEFF Research Database (Denmark)

    Abdul-Talib, S.; Ujang, Z; Vollertsen, J.

    2004-01-01

    could be simplified by a two-stage process. In the first stage, nitrate was utilised with significant accumulation of nitrite. In the second stage nitrite was utilised when nitrate depleted. Denitrification rates during the two stages were expressed in terms of electron equivalents (e-eq.) in order...... to compare the process when differennt electron acceptors namlely, nitrate and nitrite were utilised. The energy release rates during the two stages were calculated and compared....

  15. A unified model of hydride cracking based on elasto-plastic energy release rate over a finite crack extension

    International Nuclear Information System (INIS)

    Zheng, X.J.; Metzger, D.R.; Sauve, R.G.

    1995-01-01

    A fracture criterion based on energy balance is proposed for elasto-plastic cracking at hydrides in zirconium, assuming a finite length of crack advance. The proposed elasto-plastic energy release rate is applied to the crack initiation at hydrides in smooth and notched surfaces, as well as the subsequent delayed hydride cracking (DHC) considering limited crack-tip plasticity. For a smooth or notched surface of an elastic body, the fracture parameter is related to the stress intensity factor for the initiated crack. For DHC, a unique curve relates the non-dimensionalized elasto-plastic energy release rate with the length of crack extension relative to the plastic zone size. This fracture criterion explains experimental observations concerning DHC in a qualitative manner. Quantitative comparison with experiments is made for fracture toughness and DHC tests on specimens containing certain hydride structures; very good agreement is obtained. ((orig.))

  16. CONTROLLED RELEASE, BLIND TEST OF DNAPL REMEDIATION BY ETHANOL FLUSHING

    Science.gov (United States)

    A dense nonaqueous phase liquid (DNAPL) source zone was established within a sheet-pileisolated cell through a controlled release of perchloroethylene (PCE) to evaluate DNAPLremediation by in-situ cosolvent flushing. Ethanol was used as the cosolvent, and the main remedia...

  17. Sensitivity of the engineered barrier system (EBS) release rate to alternative conceptual models of advective release from waste packages under dripping fractures

    International Nuclear Information System (INIS)

    Lee, J.H.; Atkins, J.E.; McNeish, J.A.; Vallikat, V.

    1996-01-01

    The first model assumed that dripping water directly contacts the waste form inside the ''failed'' waste package and radionuclides are released from the EBS by advection. The second model assumed that dripping water is diverted around the package (because of corrosion products plugging the perforations), thereby being prevented from directly contacting the waste form. In the second model, radionuclides were assumed to diffuse through the perforations, and, once outside the waste package, to be released from the EBS by advection. For the case with the second EBS release model, most radionuclides had lower peak EBS release rates than with the first model. Impacts of the alternative EBS release models were greater for the radionuclides with low solubility. The analysis indicated that the EBS release model representing advection through a ''failed'' waste package (the first model) may be too conservative; thus a ''failed'' waste package container with multiple perforations may still be an important barrier to radionuclide release

  18. Phenazopyridine-phthalimide nano-cocrystal: Release rate and oral bioavailability enhancement.

    Science.gov (United States)

    Huang, Yu; Li, Jin-Mei; Lai, Zhi-Hui; Wu, Jun; Lu, Tong-Bu; Chen, Jia-Mei

    2017-11-15

    Both cocrystal and nanocrystal technologies have been widely used in the pharmaceutical development for poorly soluble drugs. However, the synergistic effects due to the integration of these two technologies have not been well investigated. The aim of this study is to develop a nano-sized cocrystal of phenazopyridine (PAP) with phthalimide (PI) to enhance the release rate and oral bioavailability of PAP. A PAP-PI nano-cocrystal with particle diameter of 21.4±0.1nm was successfully prepared via a sonochemical approach and characterized by powder X-ray diffraction (PXRD), differential scanning calorimetry (DSC), scanning electron microscopy (SEM) and dynamic light scattering (DLS) analysis. An in vitro release study revealed a significant release rate enhancement for PAP-PI nano-cocrystal as compared to PAP-PI cocrystal and PAP hydrochloride salt. Further, a comparative oral bioavailability study in rats indicated significant improvement in C max and oral bioavailability (AUC 0-∞ ) by 1.39- and 2.44-fold, respectively. This study demonstrated that this novel nano-cocrystal technology can be a new promising option to improve release rate and absorption of poorly soluble compounds in the pharmaceutical industry. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Tritium breeding and release-rate kinetics from neutron-irradiated lithium oxide

    International Nuclear Information System (INIS)

    Quanci, J.F.

    1989-01-01

    The research encompasses the measurement of the tritium breeding and release-rate kinetics from lithium oxide, a ceramic tritium-breeding material. A thermal extraction apparatus which allows the accurate measurement of the total tritium inventory and release rate from lithium oxide samples under different temperatures, pressures and carrier-gas compositions with an uncertainty not exceeding 3% was developed. The goal of the Lithium Blanket Module program was to determine if advanced computer codes could accurately predict the tritium production in the lithium oxide blanket of a fusion power plant. A fusion blanket module prototype was built and irradiated with a deuterium-tritium fusion-neutron source. The tritium production throughout the module was modeled with the MCNP three dimensional Monte Carlo code and was compared to the assay of the tritium bred in the module. The MCNP code accurately predicted tritium-breeding trends but underestimated the overall tritium breeding by 30%. The release rate of tritium from small grain polycrystalline sintered lithium oxides with a helium carrier gas from 300 to 450 C was found to be controlled by the first order surface desorption of monotritiated water. When small amounts of hydrogen were added to the helium carrier gas, the first order rate constant increased from the isotopic exchange of hydrogen for tritium at the lithium oxide surface occurring in parallel with the first order desorption process. The isotopic-exchange first order rate constant temperature dependence and hydrogen partial pressure dependence were evaluated

  20. Test Review: Autism Spectrum Rating Scales

    Science.gov (United States)

    Simek, Amber N.; Wahlberg, Andrea C.

    2011-01-01

    This article reviews Autism Spectrum Rating Scales (ASRS) which are designed to measure behaviors in children between the ages of 2 and 18 that are associated with disorders on the autism spectrum as rated by parents/caregivers and/or teachers. The rating scales include items related to behaviors associated with Autism, Asperger's Disorder, and…

  1. Application of reaction type of C-peptide release test in diabetes mellitus

    International Nuclear Information System (INIS)

    Chen Dong; Duan Wenruo; He Juan; Lu Zhenfang

    2001-01-01

    The author is to confirm the effect of C-peptide release test and types of release reaction in appraisal of pancreas function of β-cell and selection of treatment for diabetes mellitus (DM) patients. The serum C-peptide release test of 67 normal controls and 217 DM patients were determined by RIA, and the results were analyzed and compared. C-peptide release test can reflect the pancreas function of β-cell better, the peak of C-peptide ≥ 0.6 nmol/L after lunch can be the limit of whether to reduce the level of blood glucose only by oral drug. The authors should adjust the treatment through analyzing the type of C-peptide release reaction. C-peptide release test is very important in evaluating the pancreas function of β-cell, classifying the type of DM and selecting the treatment

  2. Code of practice for the release of hydrostatic test water from hydrostatic testing of petroleum liquid and gas pipelines

    International Nuclear Information System (INIS)

    1999-01-01

    This booklet describes a series of administrative procedures regarding the code of practice in Alberta for the release of hydrostatic test water from hydrostatic testing of petroleum liquid and gas pipelines. The topics covered include the registration process, the type and quality of water to use during the test, and the analytical methods to be used. Reporting schedule and record keeping information are also covered. Schedule 1 discusses the requirements for the release of hydrostatic test water to land, while Schedule 2 describes the requirements for the release of hydrostatic test water to receiving water. 3 tabs

  3. NEK containment integrated leak rate test at full pressure

    International Nuclear Information System (INIS)

    Skaler, F.; Planinc, V.; Gregoric, D.; Cicvaric, D.

    1999-01-01

    NPP Krsko is a Pressure Water Reactor (PWR) Plant which has four barriers to prevent release of radioactive fission products. These four barriers are following: Fuel itself, Fuel Clad, Reactor Coolant System and Containment Building. Containment is the last barrier which can prevent release of fission product when other barriers have been already broken. To find out the real condition of containment vessel and to prove its ability of withstanding increased parameters during accident we have to perform Containment Integrated Leak Rate Test at least three times in every ten years of operation. CILRT 1999 in NPP Krsko was completely performed following regulation of 10CFR50 App. J Option A and ANSI/ANS 56.8-1987. The main goal of CILRT is to prove that the leakage of containment pathways and wall structures are within limits prescribed in Technical Specifications by pressurization of containment building above peak accident pressure Pa and measuring the mass changes of air using Ideal Gas Law.(author)

  4. Impaired sarcoplasmic reticulum Ca(2+) release rate after fatiguing stimulation in rat skeletal muscle

    DEFF Research Database (Denmark)

    Ørtenblad, Niels; Sjøgaard, G; Madsen, Klavs

    2000-01-01

    during the first 0.5-1 h the metabolic state recovered to resting levels, and a slow phase from 1-3 h characterized by a rather slow recovery of the mechanical properties. The recovery of SR Ca(2+) release rate was closely correlated to +dF/dt during the slow phase of recovery (r(2) = 0.51; P ... to 66% that persisted for 1 h, followed by a gradual recovery to 87% of prefatigue release rate at 3 h recovery. Tetanic force and rate of force development (+dF/dt) and relaxation (-dF/dt) were depressed by approximately 80% after stimulation. Recovery occurred in two phases: an initial phase, in which......The purpose of the study was to characterize the sarcoplasmic reticulum (SR) function and contractile properties before and during recovery from fatigue in the rat extensor digitorum longus muscle. Fatiguing contractions (60 Hz, 150 ms/s for 4 min) induced a reduction of the SR Ca(2+) release rate...

  5. Nanoscale architectural tuning of parylene patch devices to control therapeutic release rates

    International Nuclear Information System (INIS)

    Pierstorff, Erik; Lam, Robert; Ho, Dean

    2008-01-01

    The advent of therapeutic functionalized implant coatings has significantly impacted the medical device field by enabling prolonged device functionality for enhanced patient treatment. Incorporation of drug release from a stable, biocompatible surface is instrumental in decreasing systemic application of toxic therapeutics and increasing the lifespan of implants by the incorporation of antibiotics and anti-inflammatories. In this study, we have developed a parylene C-based device for controlled release of Doxorubicin, an anti-cancer chemotherapy and definitive read-out for preserved drug functionality, and further characterized the parylene deposition condition-dependent tunability of drug release. Drug release is controlled by the deposition of a layer of 20-200 nm thick parylene over the drug layer. This places a porous layer above the Doxorubicin, limiting drug elution based on drug accessibility to solvent and the solvent used. An increase in the thickness of the porous top layer prolongs the elution of active drug from the device from, in the conditions tested, the order of 10 min to the order of 2 d in water and from the order of 10 min to no elution in PBS. Thus, the controlled release of an anti-cancer therapeutic has been achieved via scalably fabricated, parylene C-encapsulated drug delivery devices.

  6. Production of an experimental bonding agent containing doxycyicline as matrix metalloproteinase inhibitor, and its release rate

    Directory of Open Access Journals (Sweden)

    Ghavam M

    2010-01-01

    Full Text Available Background and Aims: In spite of the advances achieved in the field of dentin adhesives, the longevity of bond to dentin is still a challenge. According to recent studies, Matrix Metaloproteinase (MMP inhibitors can increase clinical longevity of bonding and decrease leakage. The aim of this study was to evaluate the amount and pattern of doxycycline release from an experimental dentin adhesive containing this MMP inhibitor. Materials and Methods: In this experimental study, specimens containing 0.25 and 0.5 loading percent of doxycycline in an experimental monomer were prepared in cylindrical moulds of 12 mm diameter and 2 mm thickness. The adhesive monomer was composed of 12 wt% Bis-GMA, 10 wt% TMPTMA, 28 wt% HEMA and 50 wt% ethanol. Camphorquinone and amine were used as initiators. Results: Addition of 0.25 and 0.5 w% doxycycline showed linear release in both groups. Increasing the loading percent of doxycycline caused more release. The release continued during the test period. Conclusion: Doxycycline release was observed from the experimental adhesive. Further studies in this field will help in preparing adhesive systems with more clinical longevity.

  7. Sensitivity of the engineered barrier system (EBS) release rate to alternative conceptual models of advective release from waste packages under dripping fractures

    International Nuclear Information System (INIS)

    Lee, J.H.; Atkins, J.E.; McNeish, J.A.; Vallikat, V.

    1996-01-01

    Simulations were conducted to analyze the sensitivity of the engineered barrier system (EBS) release rate to alternative conceptual models of the advective release from waste packages under dripping fractures. The first conceptual model assumed that dripping water directly contacts the waste form inside the 'failed' waste package, and radionuclides are released from the EBS by advection. The second conceptual model assumed that dripping water is diverted around the 'failed' waste package (because of the presence of corrosion products plugging the perforations) and dripping water is prevented from directly contacting the waste form. In the second model, radionuclides were assumed to transport through the perforations by diffusion, and, once outside the waste package, to be released from the EBS by advection. The second model was to incorporate more realism into the EBS release calculations. For the case with the second EBS release model, most radionuclides had significantly lower peak EBS release rates (from at least one to several orders of magnitude) than with the first EBS release model. The impacts of the alternative EBS release models were greater for the radionuclides with a low solubility (or solubility-limited radionuclides) than for the radionuclides with a high solubility (or waste form dissolution-limited radionuclides). The analyses indicated that the EBS release model representing advection through a 'failed' waste package (the first EBS release model) may be too conservative in predicting the EBS performance. One major implication from this sensitivity study was that a 'failed' waste package container with multiple perforations may still be able to perform effectively as an important barrier to radionuclide release. (author)

  8. Comparison of the release of constituents from granular materials under batch and column testing.

    Science.gov (United States)

    Lopez Meza, Sarynna; Garrabrants, Andrew C; van der Sloot, Hans; Kosson, David S

    2008-01-01

    Column leaching testing can be considered a better basis for assessing field impact data than any other available batch test method and thus provides a fundamental basis from which to estimate constituent release under a variety of field conditions. However, column testing is time-intensive compared to the more simplified batch testing, and may not always be a viable option when making decisions for material reuse. Batch tests are used most frequently as a simple tool for compliance or quality control reasons. Therefore, it is important to compare the release that occurs under batch and column testing, and establish conservative interpretation protocols for extrapolation from batch data when column data are not available. Five different materials (concrete, construction debris, aluminum recycling residue, coal fly ash and bottom ash) were evaluated via batch and column testing, including different column flow regimes (continuously saturated and intermittent unsaturated flow). Constituent release data from batch and column tests were compared. Results showed no significant difference between the column flow regimes when constituent release data from batch and column tests were compared. In most cases batch and column testing agreed when presented in the form of cumulative release. For arsenic in carbonated materials, however, batch testing underestimates the column constituent release for most LS ratios and also on a cumulative basis. For cases when As is a constituent of concern, column testing may be required.

  9. Closure report for CAU No. 450: Historical UST release sites, Nevada Test Site. Volume 1

    International Nuclear Information System (INIS)

    1997-09-01

    This report addresses the closure of 11 historical underground storage tank (UST) release sites within various areas of the Nevada Test Site (NTS). The closure of each hydrocarbon release has not been documented, therefore, this report addresses the remedial activities completed for each release site. The hydrocarbon release associated with each tank site within CAU 450 was remediated by excavating the impacted soil. Clean closure of the release was verified through soil sample analysis by an off-site laboratory. All release closure activities were completed following standard environmental and regulatory guidelines. Based upon site observations during the remedial activities and the soil sample analytical results, which indicated that soil concentrations were below the Nevada Administrative code (NAC) Action Level of 100 mg/kg, it is anticipated that each of the release CASs be closed without further action

  10. Accelerated in vitro release testing method for naltrexone loaded PLGA microspheres.

    Science.gov (United States)

    Andhariya, Janki V; Choi, Stephanie; Wang, Yan; Zou, Yuan; Burgess, Diane J; Shen, Jie

    2017-03-30

    The objective of the present study was to develop a discriminatory and reproducible accelerated release testing method for naltrexone loaded parenteral polymeric microspheres. The commercially available naltrexone microsphere product (Vivitrol ® ) was used as the testing formulation in the in vitro release method development, and both sample-and-separate and USP apparatus 4 methods were investigated. Following an in vitro drug stability study, frequent media replacement and addition of anti-oxidant in the release medium were used to prevent degradation of naltrexone during release testing at "real-time" (37°C) and "accelerated" (45°C), respectively. The USP apparatus 4 method was more reproducible than the sample-and-separate method. In addition, the accelerated release profile obtained using USP apparatus 4 had a shortened release duration (within seven days), and good correlation with the "real-time" release profile. Lastly, the discriminatory ability of the developed accelerated release method was assessed using compositionally equivalent naltrexone microspheres with different release characteristics. The developed accelerated USP apparatus 4 release method was able to detect differences in the release characteristics of the prepared naltrexone microspheres. Moreover, a linear correlation was observed between the "real-time" and accelerated release profiles of all the formulations investigated, suggesting that the release mechanism(s) may be similar under both conditions. These results indicate that the developed accelerated USP apparatus 4 method has the potential to be an appropriate fast quality control tool for long-acting naltrexone PLGA microspheres. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Summary of accidental releases of radioactivity detected off the Nevada Test Site, 1963--1986

    International Nuclear Information System (INIS)

    Patzer, R.G.; Phillips, W.G.; Grossman, R.F.; Black, S.C.; Costa, C.F.

    1988-08-01

    Of the more than 450 underground nuclear explosives tests conducted at the Nevada Test Site from August 1963 (signing of the Limited Test Ban Treaty) through the end of 1986, only 23 accidentally released radioactivity that was detectable beyond the boundary of the NTS. Of these 23, 4 were detectable off the NTS only by aircraft while the remainder were detectable by ground monitoring instruments. Since the Baneberry venting of December 1970, only two tests released radioactivity that was detectable off the NTS, and this was a seepage of radioactive noble gases. None of these releases from underground tests designed for complete containment caused exposure of the population living in the area that exceeded standards recommended by national and international radiation protection agencies. This report summarizes the releases from each of the tests, describes the monitoring that was conducted, and lists the location of the maximum exposure

  12. WATER HYACINTH: A POSSIBLE ALTERNATIVE RATE RETARDING NATURAL POLYMER USED IN SUSTAINED RELEASE TABLET DESIGN

    Directory of Open Access Journals (Sweden)

    Sabera eKhatun

    2014-06-01

    Full Text Available In recent years natural polymers have been widely used, because of their effectiveness and availability over synthetic polymers. In this present investigation matrix tablets of Metformin hydrochloride were formulated using Water hyacinth powder and its rate retardant activity was studied. Tablets were prepared using wet granulation method with 8% starch as granulating agent and 5%, 10%, 15%, 20%, 25% and 30% of Water hyacinth powder to the drug. In preformulation study, angle of repose, Carr’s Index and Hausner ratio were calculated. Fourier Transform Infrared Spectroscopy (FTIR, Differential Scanning Calorimetry (DSC and Scanning Electron Microscopy (SEM studies were performed and no interactions were found between drug and excipients. Weight variation, friability, hardness, thickness, diameter, and in vitro release study were performed with the prepared matrix tablets. Dissolution studies were conducted using USP type II apparatus at a speed of 100 rpm at 37oC ± 0.5 temperature, for 8 hours. All the formulations comply with both BP and USP requirements, but among all the formulations F-1 (5% of Water hyacinth was the best fitted formula. The drug release patterns were explained in different kinetic models such as Zero order, First order, Higuchi, Hixson Crowell and Korsmeyer-Peppas equations. The current investigation implies that Water hyacinth has the potential to be used as a rate-retarding agent in sustained release drug formulations.

  13. Water hyacinth: a possible alternative rate retarding natural polymer used in sustained release tablet design.

    Science.gov (United States)

    Khatun, Sabera; Sutradhar, Kumar B

    2014-01-01

    In recent years natural polymers have been widely used because of their effectiveness and availability over synthetic polymers. In this present investigation matrix tablets of Metformin hydrochloride were formulated using Water hyacinth powder and its rate retardant activity was studied. Tablets were prepared using wet granulation method with 8% starch as granulating agent and 5, 10, 15, 20, 25 and 30% of Water hyacinth powder to the drug. In preformulation study, angle of repose, Carr's Index and Hausner ratio were calculated. Fourier Transform Infrared Spectroscopy (FTIR), Differential Scanning Calorimetry (DSC), and Scanning Electron Microscopy (SEM) studies were performed and no interactions were found between drug and excipients. Weight variation, friability, hardness, thickness, diameter, and in vitro release study were performed with the prepared matrix tablets. Dissolution studies were conducted using USP type II apparatus at a speed of 100 rpm at 37°C ± 0.5 temperature for 8 h. Though all the formulations comply with both BP and USP requirements, formulation F-1 (5% of Water hyacinth) was the best fitted formula. The drug release patterns were explained in different kinetic models such as Zero order, First order, Higuchi, Hixson Crowell, and Korsmeyer-Peppas equations. The current investigation implies that Water hyacinth has the potential to be used as a rate-retarding agent in sustained release drug formulations.

  14. Aerosol material release rates from zircaloy-4 at temperatures from 2000 to 22000C

    International Nuclear Information System (INIS)

    Mulpuru, S.R.; Wren, D.J.; Rondeau, R.K.

    1987-01-01

    During some postulated severe accidents involving loss of coolant and loss of emergency coolant injection, the temperatures in a CANDU reactor fuel channel become high enough to cause failure and melting of the Zircaloy fuel cladding. At such high temperatures, vapors of fission products and structural (fuel and cladding) materials will be released into the coolant steam and hydrogen mixture. These vapors will condense as cooler conditions are encountered downstream. The vapors from structural materials are relatively involatile; therefore, they will condense readily into aerosol particles. These particles, in turn, will provide sites for the condensation of the more volatile fission products. The aerosol transport of fission products in the primary heat transport system (PHTS) will thus be influenced by the structural material release rates. As part of an ongoing program to develop predictive tools for aerosol and associated fission product transport through the PHTS, experiments have been conducted to measure the vapor mass release rates of the alloying elements from Zircaloy-4 at high temperatures. The paper presents the results and analysis of these experiments

  15. Release of radioactive materials in simulation test of a postulated solvent fire in a nuclear fuel reprocessing plant

    International Nuclear Information System (INIS)

    Nishio, G.; Hashimoto, K.

    1989-01-01

    This paper reports on small- and large-scale fire tests performed to examine the adequacy of a safety evaluation method for a solvent fire in the extraction process of a nuclear fuel reprocessing plant. The test objectives were to obtain information on the confinement of radioactive materials during a 30% tri-n-butyl phosphate-n-dodecane fire while air ventilation is operating in the cell. The rates of release of cesium, strontium, cerium, ruthenium, and uranium from a burning solvent were determined. The quantities of species released were obtained from the solvent burning rate, smoke generation rate, partition coefficients of species between solvent and water, and coefficients of species entrainment to atmosphere in cell

  16. Rates and mechanisms of radioactive release and retention inside a waste disposal canister - in Can Processes

    Energy Technology Data Exchange (ETDEWEB)

    Oversby, V.M. (ed.) [and others

    2003-10-01

    the system that will not be present under long term disposal conditions. A simulation of long-term conditions can be done using uranium dioxide that contains a short-lived isotope of uranium, but this will not include the effects of fission product and higher actinide elements on the behaviour of the spent fuel. We designed a project that had as its objective to improve the scientific understanding of the processes that control release of radioactive species from spent fuel inside a disposal canister and the chemical changes in those species that might limit release of radioactivity from the canister. If the mechanisms that control dissolution of the fuel matrix, including self-irradiation effects, can be clarified, a more realistic assessment of the long-term behaviour of spent fuel under disposal conditions can be made. By removing uncertainties concerning waste form performance, a better assessment of the individual and collective role of the engineered barriers can be made. To achieve the overall objective of the project, the following scientific and technical objectives were set. 1. Measure the actual rate of matrix dissolution of uranium dioxide under oxidising and reducing conditions. 2. Measure the effect of alpha radiolysis on the dissolution rate of uranium dioxide under oxidising and reducing conditions. 3. Measure the dissolution rate of the matrix material of spent fuel and thereby determine the additional effects of beta and gamma radiation on uranium dioxide dissolution rate under oxidising and reducing conditions. 4. Measure the ability of actively corroding iron to reduce oxidised U(VI) to U(IV) when U is present as the complex ion uranyl carbonate. 5. Measure the rate of reduction of Np(V) species in the presence of actively corroding iron. 6. Calculate the expected equilibrium and steady state concentrations of U under the conditions of the experiments used for meeting objectives 1 through 3 and compare the calculated results with those measured in

  17. 46 CFR 107.260 - Rated load test for cranes.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Rated load test for cranes. 107.260 Section 107.260... INSPECTION AND CERTIFICATION Inspection and Certification § 107.260 Rated load test for cranes. (a) To meet the requirements in § 107.231(l), each crane must meet the following rated load test at both the...

  18. Optimal integration and test plans for software releases of lithographic systems

    NARCIS (Netherlands)

    Boumen, R.; Jong, de I.S.M.; Mortel - Fronczak, van de J.M.; Rooda, J.E.

    2007-01-01

    This paper describes a method to determine the optimal integration and test plan for embedded systems software releases. The method consists of four steps: 1)describe the integration and test problem in an integration and test model which is introduced in this paper, 2) determine possible test

  19. In-pile test of tritium release from tritium breeding materials (VOM-21H experiment)

    International Nuclear Information System (INIS)

    Kurasawa, Toshimasa; Takeshita, Hidefumi; Watanabe, Hitoshi; Yoshida, Hiroshi.

    1986-10-01

    Material development and blanket design of lithium-based ceramics such as lithium oxide, lithium aluminate, lithium silicate and lithium zirconate have been performed in Japan, United State of America and Europian Communities. Lithium oxide is a most attractive candidate for tritium breeding materials because of its high lithium density, high thermal conductivity and good tritium release performance. This work has been done to clarify the characteristics of tritium release and recovery from Li 2 O by means of in-situ tritium release measurement. The effects of temperature and sweep gas composition on the tritium release were investigated in this VOM-21H Experiment. Good measurement of tritium release was achieved but there were uncertainties in reproduciblity of data. The experimental results show that the role of surface adsorption/desorption makes a significant contribution to the tritium release and tritium inventory. Also, it is necessary to define the rate limiting process either diffusion or surface adsorption/desorption. (author)

  20. Large-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Gauglitz, Phillip A.; Burns, Carolyn A.; Fountain, Matthew S.; Shimskey, Rick W.; Billing, Justin M.; Bontha, Jagannadha R.; Kurath, Dean E.; Jenks, Jeromy WJ; MacFarlan, Paul J.; Mahoney, Lenna A.

    2013-08-01

    One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used

  1. Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test.

    Science.gov (United States)

    Bregnbak, David; Johansen, Jeanne D; Jellesen, Morten S; Zachariae, Claus; Thyssen, Jacob P

    2015-11-01

    Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release at 0.5 ppm without interference from other pure metals, alloys, or leather. A market survey using the test showed no chromium(VI) release from work tools (0/100). However, chromium(VI) release from metal screws (7/60), one earring (1/50), leather shoes (4/100) and leather gloves (6/11) was observed. We found no false-positive test reactions. Confirmatory testing was performed with X-ray fluorescence (XRF) and spectrophotometrically on extraction fluids. The use of DPC as a colorimetric spot test reagent appears to be a good and valid test method for detecting the release of chromium(VI) ions from leather and metal articles. The spot test has the potential to become a valuable screening tool. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Small-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, G. N.; Mahoney, Lenna A.; Tran, Diana N.; Burns, Carolyn A.; Kurath, Dean E.

    2013-08-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the

  3. Fission Product Release from Molten Pool: ceramic melt tests

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Yu.B.; Lopukh, D.B.; Petchenkov, A.Yu. [AO ' NP Sintez' , St. Petersburg (RU)] [and others

    1999-07-01

    Experimental results are presented on the volatilisation of UO{sub 2{+-}}{sub x}, SrO, BaO, CeO{sub 2} from corium melts. Corium melts were generated by high frequency induction melting in a cold crucible. The surface temperature of the melts was in the range from 1753 to 3023 K. Some results of the tests are discussed and a comparison with published data is made. (author)

  4. Liquid-Phase Heat-Release Rates of the Systems Hydrazine-Nitric Acid and Unsymmetrical Dimethylhydrazine-Nitric Acid

    Science.gov (United States)

    Somogyi, Dezso; Feiler, Charles E.

    1960-01-01

    The initial rates of heat release produced by the reactions of hydrazine and unsymmetrical dimethylhydrazine with nitric acid were determined in a bomb calorimeter under conditions of forced mixing. Fuel-oxidant weight ratio and injection velocity were varied. The rate of heat release apparently depended on the interfacial area between the propellants. Above a narrow range of injection velocities representing a critical amount of interfacial area, the rates reached a maximum and were almost constant with injection velocity. The maximum rate for hydrazine was about 70 percent greater than that for unsymmetrical dimethylhydrazine. The total heat released did not vary with mixture ratio over the range studied.

  5. Rate-control algorithms testing by using video source model

    DEFF Research Database (Denmark)

    Belyaev, Evgeny; Turlikov, Andrey; Ukhanova, Anna

    2008-01-01

    In this paper the method of rate control algorithms testing by the use of video source model is suggested. The proposed method allows to significantly improve algorithms testing over the big test set.......In this paper the method of rate control algorithms testing by the use of video source model is suggested. The proposed method allows to significantly improve algorithms testing over the big test set....

  6. Bedside paediatric HIV testing in Malawi: Impact on testing rates

    African Journals Online (AJOL)

    2017-05-25

    May 25, 2017 ... Malawi Integrated Guidelines on 'Clinical Management of ... referred by nursing staff to attend the HIV counsellor's ... Implementation of a bedside testing service at Queen Elizabeth Central Hospital significantly increased HIV ...

  7. Applications of energy-release-rate techniques to part-through cracks in plates and cylinders. Volume 2. ORVIRT: a finite element program for energy release rate calculations for 2-dimensional and 3-dimensional crack models

    International Nuclear Information System (INIS)

    Bass, B.R.; Bryson, J.W.

    1983-02-01

    Certain studies of fracture phenomena, such as pressurized-thermal-shock of cracked structures, require that crack tip parameters be determined for combined thermal and mechanical loads. A method is proposed here that modifies the isothermal formulation of deLorenzi to account for thermal strains in cracked bodies. The formulation has been implemented in the virtual-crack-extension program ORVIRT (Oak Ridge VIRTual-Crack-Extension). Program ORVIRT performs energy release rate calculations for both 2- and 3-dimensional nonlinear models of crack configurations in engineering structures. Two applications of the ORVIRT program are described. In the first, semielliptical surface cracks in an experimental test vessel are analyzed under elastic-plastic conditions using the finite element method. The second application is a thick-walled test vessel subjected to combined pressure and thermal shock loading

  8. Variation of the energy release rate as a crack approaches and passes through an elastic inclusion

    Science.gov (United States)

    Li, Rongshun; Chudnovsky, A.

    1993-01-01

    The variation of the energy release rate (ERP) at the tip of a crack penetrating an elastic inclusion is analyzed using an approach involving modeling the random array of microcracks or other defects by an elastic inclusion with effective elastic properties. Computations are carried out using a finite element procedure. The eight-noded isoparametric serendipity element with the shift of the midpoint to the quarter-point is used to simulate the singularity at the crack tip, and the crack growth is accommodated by implementing a mesh regeneration technique. The ERP values were calculated for various crack tip positions which simulate the process of the crack approaching and penetrating the inclusion.

  9. LEAK: A source term generator for evaluating release rates from leaking vessels

    International Nuclear Information System (INIS)

    Clinton, J.H.

    1994-01-01

    An interactive computer code for estimating the rate of release of any one of several materials from a leaking tank or broken pipe leading from a tank is presented. It is generally assumed that the material in the tank is liquid. Materials included in the data base are acetonitrile, ammonia, carbon tetrachloride, chlorine, chlorine trifluoride, fluorine, hydrogen fluoride, nitric acid, nitrogen tetroxide, sodium hydroxide, sulfur hexafluoride, sulfuric acid, and uranium hexafluoride. Materials that exist only as liquid and/or vapor over expected ranges of temperature and pressure can easily be added to the data base file. The Fortran source code for LEAK and the data file are included with this report

  10. Development of DUST: A computer code that calculates release rates from a LLW disposal unit

    International Nuclear Information System (INIS)

    Sullivan, T.M.

    1992-01-01

    Performance assessment of a Low-Level Waste (LLW) disposal facility begins with an estimation of the rate at which radionuclides migrate out of the facility (i.e., the disposal unit source term). The major physical processes that influence the source term are water flow, container degradation, waste form leaching, and radionuclide transport. A computer code, DUST (Disposal Unit Source Term) has been developed which incorporates these processes in a unified manner. The DUST code improves upon existing codes as it has the capability to model multiple container failure times, multiple waste form release properties, and radionuclide specific transport properties. Verification studies performed on the code are discussed

  11. Effect of temperature and ph on the drug release rate from a polymer conjugate system

    International Nuclear Information System (INIS)

    Kenawy, E.; Abdel-Hay, F.I.; El-Newehy, M.H.; Ottenbrite, R.M.

    2005-01-01

    Hydroximide and A-methylhydroxamic acid of poly(ethylene-altmaleic anhydride) (average MW 100-500 k) were used as a carrier for a new drug delivery system. The synthesis of the hydroximide and N methylhydroxamic acid of poly(ethylene-alt-maleic anhydride) were carried out by chemical modification of poly(ethylene-alt-maleic anhydride) with hydroxylamine and N-methyl hydroxylamine, respectively, in N,N- dimethylformamide at room temperature to yield water soluble copolymer. Ketoprofen was reacted with hydroximide and N-methylhydroxamic acid derivatives of poly(ethylene-alt-maleic anhydride) using dicyclohexylcarbodiimide as condensation agent at -5 degree C to yield water insoluble ketoprofen conjugates. All products were characterized by elemental analysis, FTIR and 1HNMR spectra. The in-vitro ketoprofen release was carried out by UV spectrophotometer at max =260 nm. The results demonstrated the effectiveness of hydroximide and N-methylhydroxamic acid of polyethylene-alt-maleic anhydride) as a drug delivery system. The release rates were studied at various ph and temperatures. The copolymer-drug adducts released the drug very slowly at the low ph found in the stomach thus protecting the drug from the action of high concentrations of digestive acids. These results showed the usefulness of hydroxamic acid polymer-drug conjugates as a new drug delivery system for drugs to be targeted to sites in the GI system

  12. Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test

    DEFF Research Database (Denmark)

    Bregnbak, David; Johansen, Jeanne D.; Jellesen, Morten Stendahl

    2015-01-01

    Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit...... exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release...

  13. [Sustained-release progesterone vaginal suppositories 3-development and clinical feasibility testing].

    Science.gov (United States)

    Nakayama, Ayako; Yamaguchi, Naho; Ohno, Yukiko; Miyata, Chihiro; Kondo, Haruomi; Sunada, Hisakazu; Okamoto, Hirokazu

    2013-01-01

      Although progesterone vaginal suppositories (hospital-formulated) are used for the treatment of infertility, their half-life is so short that multiple doses are required. In this study, we aimed to develop sustained-release vaginal suppositories suitable for clinical use which maintain an effective blood concentration by once-a-day treatment, and prepared 7 types of suppository containing the sustained-release progesterone tablets to characterize their sustained-release performance. We selected one candidate suppository among them, taking recovery rate, reproducibility, and hardness, as well as the sustained-release performance into consideration. The shell of the selected suppository is composed of VOSCO S-55 and progesterone for rapid release. The molded progesterone tablets for sustained release were embedded inside. The distribution of the weight and content of the suppository was limited, and the release rate of progesterone was significantly slower than that of a conventional progesterone suppository prepared in our hospital. The single-dose administration of the selected suppository to five healthy volunteers led to significant extension of the blood concentration. We also confirmed the rise of the basic value by multiple administration. The simulation comparison suggested that the blood progesterone concentration is controlled by once-a-day administration of the selected suppository better than twice-a-day administration of the conventional suppository. In conclusion, the sustained-release vaginal suppository prepared in this study was considered to be useful for clinical treatment.

  14. Reactor building pressure proof test (PPT) and leak rate test (LRT) of Qinshan phase III (CANDU) project

    International Nuclear Information System (INIS)

    Gu Jun; Shi Jinqi; Fan Fuping

    2004-12-01

    As the first reactor building (R/B) without stainless steel liner in china, TQNPC studied the containment characteristics, such as strong concrete absorb/release air effect, poor containment penetration. etc. And carefully prepared test scheme and emergency response, creatively introduced the instrument air self-supply system in reactor building, developed the special measurement and analysis system for PPT and LRT, organized work under high-pressure on large-scale in the test. Finally got the containment leak rate result and the test-cost-time value is the best in all same type tests. (authors)

  15. Fuel behaviour and fission product release under realistic hydrogen conditions comparisons between HEVA 06 test results and Vulcain computations

    International Nuclear Information System (INIS)

    Dumas, J.M.; Lhiaubet, G.

    1989-07-01

    The HEVA 06 test was designed to simulate the conditions existing at the time when fission products are released from irradiated fuel under hydrogen conditions occurring in a PWR core at low pressure. The test conditions were defined from results provided by the core degradation module of the ESCADRE system (1): VULCAIN. This computer code has been recently used to analyse the early core degradation of a 900 MWe PWR in the AF accident sequence (as defined in WASH - 1400, USNRC - 1975). In this scenario, the core would begin to uncover about one day after scram with the system pressure at about 0.4 MPa. The fission product release starts 70 minutes after core dewatering. The F.P. are transferred to the core outlet in an increasingly hydrogen-rich steam atmosphere. The carrier gas is nearly pure hydrogen in the time period 100 - 130 minutes after core uncovering. A large release of F.P. is predicted in the upper part of the core when the steam starvation occurs. At that time, two thirds of the cladding have been oxidised on an average. Before each HEVA test a fuel sample with a burn-up of 36 GWd/tU is reirradiated in order to observe the release of short-lived fission products. A pre-oxidation was primarely conducted in the HEVA 06 test at a temperature of 1300 0 C and controlled to reach a 2/3 cladding oxidation state. Then the steam was progressively replaced by hydrogen and a heat-up rate of 1.5 0 C/s was induced to reach a temperature of 2100 0 C. The fuel was maintained at this temperature for half an hour in hydrogen. The volatile F.P. release kinetics were observed by on-line gamma spectrometry. Pre test calculations of F.P. release kinetics performed with the EMIS module based on the CORSOR models (3) are compared with the test results. Measured releases of cesium and iodine are really lower than those predicted. Axial and radial F.P. distributions in the fuel pellets are available from gamma tomography measurements performed after the test. Tellurium seems

  16. Calculations of Fission Gas Release During Ramp Tests Using Copernic Code

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Liu [Nuclear Fuel R and D Center, China Nuclear Power Technology Research Institute (CNPRI) (China)

    2013-03-15

    The report performed under IAEA research contract No.15951 describes the results of fuel performance evaluation of LWR fuel rods operated at ramp conditions using the COPERNIC code developed by AREVA. The experimental data from the Third Riso Fission Gas Project and the Studsvik SUPER-RAMP Project presented in the IFPE database of the OECD/NEA has been utilized for assessing the code itself during simulation of fission gas release (FGR). Standard code models for LWR fuel were used in simulations with parameters set properly in accordance with relevant test reports. With the help of data adjustment, the input power histories are restructured to fit the real ones, so as to ensure the validity of FGR prediction. The results obtained by COPERNIC show that different models lead to diverse predictions and discrepancies. By comparison, the COPERNIC V2.2 model (95% Upper bound) is selected as the standard FGR model in this report and the FGR phenomenon is properly simulated by the code. To interpret the large discrepancies of some certain PK rods, the burst effect of FGR which is taken into consideration in COPERNIC is described and the influence of the input power histories is extrapolated. In addition, the real-time tracking capability of COPERNIC is tested against experimental data. In the process of investigation, two main dominant factors influencing the measured gas release rate are described and different mechanisms are analyzed. With the limited predicting capacity, accurate predictions cannot be carried out on abrupt changes of FGR during ramp tests by COPERNIC and improvements may be necessary to some relevant models. (author)

  17. Evaluating release alternatives for a long-lived bird species under uncertainty about long-term demographic rates

    Science.gov (United States)

    Moore, Clinton T.; Converse, Sarah J.; Folk, Martin J.; Runge, Michael C.; Nesbitt, Stephen A.

    2012-01-01

    The release of animals to reestablish an extirpated population is a decision problem that is often attended by considerable uncertainty about the probability of success. Annual releases of captive-reared juvenile Whooping Cranes (Grus americana) were begun in 1993 in central Florida, USA, to establish a breeding, non-migratory population. Over a 12-year period, 286 birds were released, but by 2004, the introduced flock had produced only four wild-fledged birds. Consequently, releases were halted over managers' concerns about the performance of the released flock and uncertainty about the efficacy of further releases. We used data on marked, released birds to develop predictive models for addressing whether releases should be resumed, and if so, under what schedule. To examine the outcome of different release scenarios, we simulated the survival and productivity of individual female birds under a baseline model that recognized age and breeding-class structure and which incorporated empirically estimated stochastic elements. As data on wild-fledged birds from captive-reared parents were sparse, a key uncertainty that confronts release decision-making is whether captive-reared birds and their offspring share the same vital rates. Therefore, we used data on the only population of wild Whooping Cranes in existence to construct two alternatives to the baseline model. The probability of population persistence was highly sensitive to the choice of these three models. Under the baseline model, extirpation of the population was nearly certain under any scenario of resumed releases. In contrast, the model based on estimates from wild birds projected a high probability of persistence under any release scenario, including cessation of releases. Therefore, belief in either of these models suggests that further releases are an ineffective use of resources. In the third model, which simulated a population Allee effect, population persistence was sensitive to the release decision

  18. Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings.

    Science.gov (United States)

    Shen, Jie; Burgess, Diane J

    2012-01-17

    Dexamethasone loaded poly(lactic-co-glycolic acid) (PLGA) microsphere/PVA hydrogel composites have been investigated as an outer drug-eluting coating for implantable devices such as glucose sensors to counter negative tissue responses to implants. The objective of this study was to develop a discriminatory, accelerated in vitro release testing method for this drug-eluting coating using United States Pharmacopeia (USP) apparatus 4. Polymer degradation and drug release kinetics were investigated under "real-time" and accelerated conditions (i.e. extreme pH, hydro-alcoholic solutions and elevated temperatures). Compared to "real-time" conditions, the initial burst and lag phases were similar using hydro-alcoholic solutions and extreme pH conditions, while the secondary apparent zero-order release phase was slightly accelerated. Elevated temperatures resulted in a significant acceleration of dexamethasone release. The accelerated release data were able to predict "real-time" release when applying the Arrhenius equation. Microsphere batches with faster and slower release profiles were investigated under "real-time" and elevated temperature (60°C) conditions to determine the discriminatory ability of the method. The results demonstrated both the feasibility and the discriminatory ability of this USP apparatus 4 method for in vitro release testing of drug loaded PLGA microsphere/PVA hydrogel composites. This method may be appropriate for similar drug/device combination products and drug delivery systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Study on crack propagation of adhesively bonded DCB for aluminum foam using energy release rate

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Hye Jin; Lee, Sang Kyo; Cho, Chong Du [Inha University, Incheon (Korea, Republic of); Cho, Jae Ung [Kongju National University, Choenan (Korea, Republic of)

    2015-01-15

    Aluminum foam with initial crack, which has a closed cell form adhesively bonded, is studied to compare and analyze the crack propagation behavior by using both experimental and finite element analysis techniques. The specimen is loaded in Mode I type of fracture as 15 mm/min speed of a displacement control method. The experimental results were used to accommodate the finite element analysis performed with commercial software ABAQUS 6.10. First, using a video recording, five steps of experiment were selected at random and then the energy release rate was calculated. The estimated energy release rate was then used as fracture energy into the finite element analysis. Comparing the experimental axial load-displacement graphs and the finite element analysis results, roughly equivalent peak values were observed in the cohesive strength of the aluminum foam double cantilever beam. However, force versus displacement patterns showed somewhat different: little deformation was observed in aluminum foam, whereas adhesive parts in double cantilever beam were significantly deformed.

  20. Tests on the release of fission and activation products during core meltdown

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, H; Krause, W; Wild, H

    1976-01-01

    The first available results are related to tests in which the release of the main components of the core melt, namely the steel, zircaloy and uranium components, was determined using ThO/sub 2/ crucibles. The release products are dispersed onto the pipe walls of the transport system and the measuring filters which were installed at about 1 m distance from the melt crucibles. Of these, only the precipitates on the filters have been analyzed so far. In the tests under air, the release was clearly dependent on the maximum temperature reached. The release values for Mo and Mn were the highest with 5-10%; uranium with 0.1% on the other hand, was the lowest. In a steam atmosphere over the melt, the analysis of the filter precipitates for all elements gave considerably lower values than with the tests in air.

  1. Testing Optimum Seeding Rates for five Bread Wheat Cultivars

    International Nuclear Information System (INIS)

    Wekesa, S.J.; Kiriswa, F.; Owuoche, J.

    1999-01-01

    A cultivar by seed rate trial was conducted in 1994-1995 crop seasons at Njoro, Kenya. Yield results were found to be significant (P > 0.01) for year, variety, seed rate and year by seed rate interaction. Test weight was highly significant (P -1 were grouped together for significantly higher yields (A) whereas seed rates 85 and 50 kg ha -1 had lower significant yields (B and C respectively). The same grouping was repeated for test weight. There was no significant cultivar by seed rate interaction and no cultivar, specific seed rate. However, since seed rates 245, 205, 165 and 125 kg ha -1 were grouped together, the lowest seed rate, 125 kg ha -1 can be recommended as the optimum seed rate for the above cultivars, as higher seed rates do not give significantly higher yields or higher test weights

  2. Functional Testing Differences in Anterior Cruciate Ligament Reconstruction Patients Released Versus Not Released to Return to Sport.

    Science.gov (United States)

    Mayer, Stephanie W; Queen, Robin M; Taylor, Dean; Moorman, Claude T; Toth, Allison P; Garrett, William E; Butler, Robert J

    2015-07-01

    No standardized return-to-activity or sport guidelines currently exist after anterior cruciate ligament (ACL) reconstruction. Isokinetic testing and unilateral hop testing, which have construct validity, are often used to make the determination of when a patient is ready to return to sport. Neither of these measures has been reported to be predictive of subsequent injuries. To compare the performance on 2 functional tests of ACL reconstruction patients released to return to activity versus those who have not been released based on clinical impairment measures. Cohort study; Level of evidence, 3. A total of 98 patients were examined by the treating orthopaedic surgeon 6 months after ACL reconstruction for traditional impairment measures, including swelling, range of motion, strength, and graft stability. After this examination, all subjects completed the functional testing, consisting of the Functional Movement Screen (FMS) and the Lower Quarter Y Balance Test (YBT-LQ), by an experienced tester who was blinded to the results of the clinical examination. On the basis of the clinical examination, all patients were grouped as being ready to return to sport or not being ready. Performance on the functional tests, as measured by overall performance and side-to-side asymmetry, was compared between the 2 groups using independent-samples t tests (P < .05). No difference existed between the groups with regard to the descriptive characteristics, with the exception that the group not cleared was younger (21.0 ± 7.4 years) than the group that was cleared (25.6 ± 13.2 years). Performance on the YBT-LQ revealed that no differences existed between groups when examining reach symmetry for any of the reach directions. In addition, no differences were found between groups when looking at the average reach score normalized to limb length for either the surgical or nonsurgical leg. Patients in the cleared group exhibited a similar score on the FMS (12.7 ± 2.9) compared with the

  3. The Relationship between Toxics Release Inventory Discharges and Mortality Rates in Rural and Urban Areas of the United States

    Science.gov (United States)

    Hendryx, Michael; Fedorko, Evan

    2011-01-01

    Background: Potential environmental exposures from chemical manufacturing or industrial sites have not been well studied for rural populations. The current study examines whether chemical releases from facilities monitored through the Toxics Release Inventory (TRI) program are associated with population mortality rates for both rural and urban…

  4. Unexpectedly high catch-and-release rates in European marine recreational fisheries: implications for science and management

    DEFF Research Database (Denmark)

    Ferter, Keno; Weltersbach, Marc Simon; Strehlow, Harry Vincent

    2013-01-01

    Unexpectedly high catch-and-release rates in European marine recreational fisheries: implications for science and management. – ICES Journal of Marine Science, 70: .While catch-and-release (C&R) is a well-known practice in several European freshwater recreational fisheries, studies on the magnitu...

  5. Short-term Outcomes following Concussion in the NFL: An 11-year Retrospective Study of Player Release Rate and Financial Loss

    Science.gov (United States)

    Ramkumar, Prem; Navarro, Sergio Michael

    2017-01-01

    Objectives: The primary goal of this study was to assess the short-term outcomes among National Football League (NFL) players following concussion in terms of: (1) DNP protocol activation, (2) release rate at one and three years, and (3) mean salary reduction. A secondary goal of the study was to stratify the post-concussive release rate by franchise and player position. Methods: NFL player transaction records and publicly available weekly injury reports from August 2005 to January 2016 for NFL players were analyzed. All players immediately sustaining recorded concussions were evaluated for a change to inactive or do-not-play (DNP) status. The one-year and three-year release rate following concussion was defined as any player transitioning to inactivation, retirement, free agency, or any failure to return for a successive season on the same team’s active roster after one or three years from the initial concussion. Student’s t-test was used to compare release rates between non-concussed and concussed players at one and three years. Mean salary reduction per year following concussion was calculated using publicly available player contracts. Additionally, franchise-level and position-based analyses of the release rate were performed. Results: Of the total 5,451 NFL players retrospectively analyzed over the 11-year period, 373 sustained publicly reported concussions resulting in DNP protocol activation. The release rate of the post-concussive versus non-concussive player was 26% vs. 20% at 1 year (pfranchise to release an athlete following concussion within one and three years. Table 1 reports a position-based analysis in terms of concussion rate, mean salary reduction, and NFL career longevity. Conclusion: Our retrospective study demonstrates that NFL concussions resulting in DNP protocol activation leads to a statistically greater release rate among concussed NFL players than non-concussed players. Released players suffered reduction in year-over-year accumulated

  6. Screening health care workers with interferon-γ release assay versus tuberculin skin test: impact on costs and adherence to testing (the SWITCH study).

    Science.gov (United States)

    Wrighton-Smith, Peter; Sneed, Laurie; Humphrey, Frances; Tao, Xuguang; Bernacki, Edward

    2012-07-01

    To determine the price point at which an interferon-γ release assay (IGRA) is less costly than a tuberculin skin test (TST) for health care employee tuberculosis screening. A multidecision tree-based cost model incorporating inputs gathered from time-motion studies and parallel testing by IGRA and TST was conducted in a subset of our employees. Administering a TST testing program costs $73.20 per person screened, $90.80 per new hire, and $63.42 per annual screen. Use of an IGRA for employee health testing is cost saving at an IGRA test cost of $54.83 or less per test and resulted in higher completion rates because of the elimination of the need for a second visit to interpret the TST. Using an IGRA for employee health screening can be an institutional cost saving and results in higher compliance rates.

  7. LMFBR safety: Interim test report for the characterization of released particle tests conducted at INEL during FY 1979

    International Nuclear Information System (INIS)

    Johnson, R.P.; Nelson, C.T.

    1979-01-01

    Two additional atmospheric sodium release tests were jointly conducted by ESG and ARL at INEL. These tests were conducted under very stable (Pasquill E and G) meteorological conditions where the natural humidity content was high (47 and 96% RH). Sufficient experimental data was obtained on Test 7 to quantitatively qualify the formation of Na 2 CO 3 in the open atmosphere from primary sodium combustion products. These data show that a maximum concentration of approx. 60% Na 2 CO 3 is reached with the plume 100 meters from the release point. This concentration increases slightly as the plume is dispersed beyond 2400 meters. The available particle fallout data is consistent with predictions

  8. Strength of wood versus rate of testing - A theoretical approach

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    2007-01-01

    Strength of wood is normally measured in ramp load experiments. Experience shows that strength increases with increasing rate of testing. This feature is considered theoretically in this paper. It is shown that the influence of testing rate is a phenomenon, which depends on the quality...... of the considered wood. Low quality wood shows lesser influence of testing rate. This observation agrees with the well-known statement made by Borg Madsen that weak wood subjected to a constant load, has a longer lifetime than strong wood. In general, the influence of testing rate on strength increases...

  9. Influence of Groundwater Flow Rate on Nuclide Releases from Pyro-processed Waste Repository

    International Nuclear Information System (INIS)

    Lee, Youn Myoung; Jeong, Jong Tae

    2011-01-01

    Since the early 2000s several template programs for the safety assessment of a high-level radioactive waste repository as well as a low- and intermediate level radioactive waste repository systems have been developed by utilizing GoldSim and AMBER at KAERI. Very recently, another template program for a conceptual hybrid-typed repository system, called 'A-KRS' in which two kinds of pyroprocessed radioactive wastes, low-level metal wastes and ceramic high-level wastes that arise from pyroprocessing of PWR nuclear spent fuels has been developed and are to be disposed of by separate disposal strategies. The A-KRS is considered to be constructed at two different depths in geological media: 200m depth, at which a possible human intrusion is considered to be limited after closure, for the pyroprocessed metal wastes with lower or no decay heat producing nuclides, and 500m depth, believed to be in the reducing condition for nuclides with a rather higher radioactivity and heat generation rate. This program is ready for total system performance assessment which is able to evaluate nuclide release from the repository and farther transport into the geosphere and biosphere under various normal, disruptive natural and manmade events, and scenarios that can occur after a failure of waste package and canister. To quantify a nuclide release and transport through the possible various pathways especially in the near-fields of the A-KRS repository system, some illustrative evaluations have been made through the study. Even though all parameter values associated with the A-KRS were assumed for the time being, the illustrative results should be informative since the evaluation of such releases is very important not only in view of the safety assessment of the repository, but also for design feedback of its performance

  10. A new method for calculating energy release rate in tunnel excavation subjected to high in situ stress

    Directory of Open Access Journals (Sweden)

    Xiao Qinghua

    2016-03-01

    Full Text Available Based on energy theory, energy release rate (EER and local energy release rate (LEER, a new index called FERR (Fractional Energy Release Rate is proposed, and this method can not only evaluate the risk of rock burst, but also can point out the location of high risk and the scale of rockburst. The FERR index is applied to the TBM assembling tunnel in Jinping Hydro Power Station II to evaluate the scale and intensity of rockburst, as well as the location where rockburst occurs. With FDM method adopted, the energy release rate of 3 excavation plans are calculated and the scale and risk of rockburst is evaluated, and the location of high risk of rockburst is also mapped. With FERR used in the evaluation, the rockburst is nicely controlled which ensured the safety and construction schedule of the project.

  11. Histamine release positive test associates with disease remission in chronic spontaneous urticaria

    DEFF Research Database (Denmark)

    Berti, A; Yacoub, M R; Skov, Per Stahl

    2017-01-01

    the correlations between HR test results and demographic features, quality of life, disease activity, clinical course, and autologous serum and plasma skin tests (ASST and APST). Results. All patients with positive HR test (9/9, 100%) had a more severe disease activity at onset (urticaria activity score, UAS > 2......Summary: Background. Histamine release (HR) test has previously been shown to predict the presence of endogenous histamine-releasing factors in chronic spontaneous urticaria (CSU). Objectives and methods. Twenty CSU patients unresponsive to antihistamine treatment were enrolled in order to evaluate...... with a positive HR test had a significant reduction of disease activity (p = 0.003) whereas patients with a negative HR test did not (p > 0.05), leading to disease remission and antihistamine treatment withdrawal in 67% (6/9) of positive HR test patients versus 18% (2/11) of negative HR test patients (p = 0...

  12. Increased survival rate by local release of diclofenac in a murine model of recurrent oral carcinoma

    Directory of Open Access Journals (Sweden)

    Will OM

    2016-10-01

    Full Text Available Olga Maria Will,1,* Nicolai Purcz,2,* Athena Chalaris,3 Carola Heneweer,4,5 Susann Boretius,1 Larissa Purcz,2 Lila Nikkola,6 Nureddin Ashammakhi,6 Holger Kalthoff,7 Claus-Christian Glüer,1 Jörg Wiltfang,2 Yahya Açil,2 Sanjay Tiwari1 1Section Biomedical Imaging, Clinic for Radiology and Neuroradiology, MOIN CC, 2Department of Oral and Maxillofacial Surgery, University Hospital Schleswig-Holstein, 3Institute of Biochemistry, Christian-Albrechts-Universität zu Kiel, 4Clinic for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Kiel, 5Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany; 6Department of Biomedical Engineering, Tampere University of Technology, Tampere, Finland; 7Institute for Experimental Cancer Research, University Hospital Schleswig-Holstein, Kiel, Germany *These authors contributed equally to this work Abstract: Despite aggressive treatment with radiation and combination chemotherapy following tumor resection, the 5-year survival rate for patients with head and neck cancer is at best only 50%. In this study, we examined the therapeutic potential of localized release of diclofenac from electrospun nanofibers generated from poly(d,l-lactide-co-glycolide polymer. Diclofenac was chosen since anti-inflammatory agents that inhibit cyclooxygenase have shown great potential in their ability to directly inhibit tumor growth as well as suppress inflammation-mediated tumor growth. A mouse resection model of oral carcinoma was developed by establishing tumor growth in the oral cavity by ultrasound-guided injection of 1 million SCC-9 cells in the floor of the mouth. Following resection, mice were allocated into four groups with the following treatment: 1 no treatment, 2 implanted scaffolds without diclofenac, 3 implanted scaffolds loaded with diclofenac, and 4 diclofenac given orally. Small animal ultrasound and magnetic resonance imaging were utilized for longitudinal

  13. Combustion Heat Release Rate Comparison of Algae Hydroprocessed Renewable Diesel to F-76 in a Two-Stroke Diesel Engine

    Science.gov (United States)

    2013-06-01

    was recorded. Figure 14 shows the gauge on the rocker arm during calibration . Figure 14. Mechanical Injector Rocker Arm Strain Gauge. D. DATA...RELEASE RATE COMPARISON OF ALGAE HYDROPROCESSED RENEWABLE DIESEL TO F-76 IN A TWO-STROKE DIESEL ENGINE by John H. Petersen June 2013 Thesis...RELEASE RATE COMPARISON OF ALGAE HYDROPROCESSED RENEWABLE DIESEL TO F-76 IN A TWO-STROKE DIESEL ENGINE 5. FUNDING NUMBERS 6. AUTHOR(S) John H

  14. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  15. Sensitivity of performance assessment of the engineered barriers to nuances of release rate criteria

    International Nuclear Information System (INIS)

    Oliver, D.L.R.

    1987-01-01

    The United States Nuclear Regulatory Commission (NRC) has established criteria for the long-term performance of proposed high-level waste repositories. As with any regulation, the criteria may be interpreted in several ways. Due to the high capital costs and the emotional political climate associated with any high-level radioactive waste repository, it is important that there be an early consensus regarding interpretations of the criteria, and what assumptions may be used to demonstrate compliance with them. This work uses analytic solutions of mass transport theory to demonstrate how sensitive performance analyses are to various nuances of the NRC release rate criterion for the engineered barriers. The analysis is directed at the proposed repository in basalt at the Hanford site in Washington State

  16. The critical release rates for the dissociating gas N204/N02/N0

    International Nuclear Information System (INIS)

    Porter, W.H.L.

    1979-03-01

    Dissociating vapour systems have certain characteristics which make them attractive as coolants, notably a large effective specific heat which is significantly greater than that for the individual components of the gas mixture, and also an enhanced boundary layer heat transfer coefficient resulting from the physical characteristics of thermal dissociation. In part these effects ensure that a dissociating gas has a greatly improved thermal capacity and heat transfer capability when compared with most inert gases. In this report the critical release rates for the dissociating vapour system N 2 0 4 -N0 2 -N0 are established, principally in the two phase region, and the thermodynamics of nitrogen tetroxide are examined. (U.K.)

  17. Conversion factors for estimating release rate of gaseous radioactivity by an aerial survey

    International Nuclear Information System (INIS)

    Saito, Kimiaki; Moriuchi, Shigeru

    1988-02-01

    Conversion factors necessary for estimating release rate of gaseous radioactivity by an aerial survey are presented. The conversion factors were determined based on calculation assuming a Gaussian plume model as a function of atmospheric stability, down-wind distance and flight height. First, the conversion factors for plumes emitting mono-energy gamma rays were calculated, then, conversion factors were constructed through convolution for the radionuclides essential in an accident of a nuclear reactor, and for mixtures of these radionuclides considering elapsed time after shutdown. These conversion factors are shown in figures, and also polynomial expressions of the conversion factors as a function of height have been decided with the least-squares method. A user can easily obtain proper conversion factors from data shown here. (author)

  18. Numerical Studies on Heat Release Rate in Room Fire on Liquid Fuel under Different Ventilation Factors

    Directory of Open Access Journals (Sweden)

    N. Cai

    2012-01-01

    Full Text Available Heat release rate (HRR of the design fire is the most important parameter in assessing building fire hazards. However, HRR in room fire was only studied by computational fluid dynamics (CFD in most of the projects determining fire safety provisions by performance-based design. In contrast to ten years ago, officers in the Far East are now having better knowledge of CFD. Two common questions are raised on CFD-predicted results on describing free boundaries; and on computing grid size. In this work, predicting HRR by the CFD model was justified with experimental room pool fire data reported earlier. The software fire dynamics simulator (FDS version 5 was selected as the CFD simulation tool. Prescribed input heating rate based on the experimental results was used with the liquid fuel model in FDS. Five different free boundary conditions were investigated to predict HRR. Grid sensitivity study was carried out using one stretched mesh and multiple uniform meshes with different grid sizes. As it is difficult to have the entire set of CFD predicted results agreed with experiments, macroscopic flow parameters on the mass flow rate through door opening predicted by CFD were also justified by another four conditions with different ventilation factors.

  19. Improving the quality of EMI Releases by leveraging the EMI Testing Infrastructure

    International Nuclear Information System (INIS)

    Aiftimiei, C; Ceccanti, A; Dongiovanni, D; Giacomini, F; Meglio, A Di

    2012-01-01

    What is an EMI Release? What is its life cycle? How is its quality assured through a continuous integration and large scale acceptance testing? These are the main questions that this article will answer, by presenting the EMI release management process with emphasis on the role played by the Testing Infrastructure in improving the quality of the middleware provided by the project. The European Middleware Initiative (EMI) is a close collaboration of four major European technology providers: ARC, gLite, UNICORE and dCache. Its main objective is to deliver a consolidated set of components for deployment in EGI (as part of the Unified Middleware Distribution, UMD), PRACE and other DCIs. The harmonized set of EMI components thus enables the interoperability and integration between Grids. EMI aims at creating an effective environment that satisfies the requirements of the scientific communities relying on it. The EMI distribution is organized in periodic major releases whose development and maintenance follow a 5-phase yearly cycle: i) requirements collection and analysis; ii) development and test planning; iii) software development, testing and certification; iv) release certification and validation and v) release and maintenance. In this article we present in detail the implementation of operational and infrastructural resources supporting the certification and validation phase of the release. The main goal of this phase is to harmonize into a single release the strongly inter-dependent products coming from various development teams through parallel certification paths. To achieve this goal the continuous integration and large scale acceptance testing performed on the EMI Testing Infrastructure plays a key role. The purpose of this infrastructure is to provide a system where both the production and the release candidate product versions are deployed. On this system inter-component testing by different product team testers can concurrently take place. The Testing

  20. Releasable activity and maximum permissible leakage rate within a transport cask of Tehran Research Reactor fuel samples

    Directory of Open Access Journals (Sweden)

    Rezaeian Mahdi

    2015-01-01

    Full Text Available Containment of a transport cask during both normal and accident conditions is important to the health and safety of the public and of the operators. Based on IAEA regulations, releasable activity and maximum permissible volumetric leakage rate within the cask containing fuel samples of Tehran Research Reactor enclosed in an irradiated capsule are calculated. The contributions to the total activity from the four sources of gas, volatile, fines, and corrosion products are treated separately. These calculations are necessary to identify an appropriate leak test that must be performed on the cask and the results can be utilized as the source term for dose evaluation in the safety assessment of the cask.

  1. Kinetic rate of iron release during artificial CO{sub 2} injection in a shallow aquifer: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Rillard, J. [Earth Sciences Department UMR CNRS 5276 University of Lyon 1, Villeurbanne (France); INERIS French National Institut of Environmental and Industrial Risk Survey, Underground Risk Division,, Verneuil en Hallate (France); Gombert, P.; Toulhoat, P. [INERIS French National Institut of Environmental and Industrial Risk Survey, Underground Risk Division,, Verneuil en Hallate (France); Zuddas, P. [Earth Sciences Department UMR CNRS 5276 University of Lyon 1, Villeurbanne (France); University Pierre and Marie Curie Paris-Sorbonne, ISTEP, Paris (France)

    2013-07-01

    We performed an injection of CO{sub 2}-saturated water in a shallow aquifer following a 'push-pull' test protocol. A specific protocol was designed to measure in situ fluid pH and redox potential with careful sampling. We found increases of dissolved calcium, magnesium, alkalinity, iron and manganese, and other trace elements. Concentrations of Fe resulting from reactivity were estimated using measured concentrations of Fe corrected by a calculated fluid dynamics coefficient. Thermodynamic equilibrium calculations suggested that ferri-hydrite Fe(OH){sub 3} dissolution is the main source of iron release. The kinetic rate of Fe(OH){sub 3} dissolution estimated by a surface protonation model indicates that the reaction order is two. Since laboratory experimental results show a reaction order of zero, we propose that the mechanism of ferri-hydrite dissolution proceeds by a more complex mechanism under natural conditions. (authors)

  2. Results of testing the Grambow rate law for use in HWVP glass durability correlations

    International Nuclear Information System (INIS)

    Kuhn, W.L.; Bunnell, L.R.

    1996-03-01

    A theory based on Grambow's work on hydration of glass as linear function of solution composition was evaluated. Use of Grambow's linear rate law for correlation of durability with glass composition is not recommended. Dissolution rate of the glass was determined using the rate of release of sodium with an ion selective electrode. This method was tested first applying it to initial dissolution rate of several glasses at several temperatures with zero initial concentration of silicic acid. HW39-2, HW39-4, and SRL-202 from Savannah River were tested; there was significant scatter in the data, with the dissolution rates of HW39 glasses and the SRL glass being comparable within this scatter. The dissolution rate of SRL-202 at 80 C and pH 7 for silicic acid concentrations 0, 25, 50, and 100% saturation, was found to decrease dramatically at only 25% of the saturated silicic acid concentration, which does not conform to the linear theory

  3. Results of aerosol code comparisons with releases from ACE MCCI tests

    International Nuclear Information System (INIS)

    Fink, J.K.; Corradini, M.; Hidaka, A.; Hontanon, E.; Mignanelli, M.A.; Schroedl, E.; Strizhov, V.

    1992-01-01

    Results of aerosol release calculations by six groups from six countries are compared with the releases from ACE MCCI Test L6. The codes used for these calculations included: SOLGASMIX-PV, SOLGASMIX Reactor 1986, CORCON.UW, VANESA 1.01, and CORCON mod2.04/VANESA 1.01. Calculations were performed with the standard VANESA 1.01 code and with modifications to the VANESA code such as the inclusion of various zirconium-silica chemical reactions. Comparisons of results from these calculations were made with Test L6 release fractions for U, Zr, Si, the fission-product elements Te, Ba, Sr, Ce, La, Mo and control materials Ag, In, and Ru. Reasonable agreement was obtained between calculations and Test L6 results for the volatile elements Ag, In and Te. Calculated releases of the low volatility fission products ranged from within an order of magnitude to five orders of magnitude of Test L6 values. Releases were over and underestimated by calculations. Poorest agreements were obtained for Mo and Si

  4. The application and evaluation of insulin release test and quantitative parameter in diabetic type II

    International Nuclear Information System (INIS)

    Huang Chenggang; Chen Xiaoyan; Guan Xiaofeng

    2002-01-01

    Objective: To analyse the curve of Insulin Release Test (IRT) about the patients whit type II diabetes, to evaluate β-cell function and the sensitivity of body to Insulin using Insulin Release Index (IRI) and Insulin Sensitivity Index (ISI), and to probe the value for clinical therapy. Methods: 1) Have a IRT of 396 cases with type II diabetes and 17 normal bodies and acquire the IRT curve, 2) Design the count methods about IRI and ISI, IRI = Ins max/Ins FBI x Δ Ins max/T max (minute), ISI=(Ins max-Ins FBI)/(Ins 180'-Ins FBI), 3) Compare IRI Changes of before and after treatment for 12 cases with no insulin release and 9 cases with less insulin release. Results: IRT curve type (No release type 21.0%, less release type 33.3%, peak delay type 36.9%, high insulin type 6.0%, release delay type 2.8%); respective IRI, ISI compared to normal, P<0.01; IRI of before and after treatment with insulin P<0.01. Conclusions: IRT Curve combining IRI and ISI can reflect accurately β-cell function with type II diabetes and the sensitivity of body to insulin, Also it has some reference value for clinical therapy

  5. Development of a Smart Release Algorithm for Mid-Air Separation of Parachute Test Articles

    Science.gov (United States)

    Moore, James W.

    2011-01-01

    The Crew Exploration Vehicle Parachute Assembly System (CPAS) project is currently developing an autonomous method to separate a capsule-shaped parachute test vehicle from an air-drop platform for use in the test program to develop and validate the parachute system for the Orion spacecraft. The CPAS project seeks to perform air-drop tests of an Orion-like boilerplate capsule. Delivery of the boilerplate capsule to the test condition has proven to be a critical and complicated task. In the current concept, the boilerplate vehicle is extracted from an aircraft on top of a Type V pallet and then separated from the pallet in mid-air. The attitude of the vehicles at separation is critical to avoiding re-contact and successfully deploying the boilerplate into a heatshield-down orientation. Neither the pallet nor the boilerplate has an active control system. However, the attitude of the mated vehicle as a function of time is somewhat predictable. CPAS engineers have designed an avionics system to monitor the attitude of the mated vehicle as it is extracted from the aircraft and command a release when the desired conditions are met. The algorithm includes contingency capabilities designed to release the test vehicle before undesirable orientations occur. The algorithm was verified with simulation and ground testing. The pre-flight development and testing is discussed and limitations of ground testing are noted. The CPAS project performed a series of three drop tests as a proof-of-concept of the release technique. These tests helped to refine the attitude instrumentation and software algorithm to be used on future tests. The drop tests are described in detail and the evolution of the release system with each test is described.

  6. Quantification of Kinetic Rate Law Parameters of Uranium Release from Sodium Autunite as a Function of Aqueous Bicarbonate Concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Gudavalli, Ravi; Katsenovich, Yelena; Wellman, Dawn M.; Lagos, Leonel; Tansel, Berrin

    2013-09-05

    ABSTRACT: Hydrogen carbonate is one of the most significant components within the uranium geochemical cycle. In aqueous solutions, hydrogen carbonate forms strong complexes with uranium. As such, aqueous bicarbonate may significantly increase the rate of uranium release from uranium minerals. Quantifying the relationship of aqueous hydrogen carbonate solutions to the rate of uranium release during dissolution is critical to understanding the long-term fate of uranium within the environment. Single-pass flow-through (SPTF) experiments were conducted to estimate the rate of uranium release from Na meta-autunite as a function of bicarbonate solutions (0.0005-0.003 M) under the pH range of 6-11 and temperatures of 5-60oC. Consistent with the results of previous investigation, the rate of uranium release from sodium autunite exhibited minimal dependency on temperature; but were strongly dependent on pH and increasing concentrations of bicarbonate solutions. Most notably at pH 7, the rate of uranium release exhibited 370 fold increases relative to the rate of uranium release in the absence of bicarbonate. However, the effect of increasing concentrations of bicarbonate solutions on the release of uranium was significantly less under higher pH conditions. It is postulated that at high pH values, surface sites are saturated with carbonate, thus the addition of more bicarbonate would have less effect on uranium release. Results indicate the activation energies were unaffected by temperature and bicarbonate concentration variations, but were strongly dependent on pH conditions. As pH increased from 6 to 11, activation energy values were observed to decrease from 29.94 kJ mol-1 to 13.07 kJ mol-1. The calculated activation energies suggest a surface controlled dissolution mechanism.

  7. A Web Based Framework for Pre-release Testing of Mobile Applications

    Directory of Open Access Journals (Sweden)

    Hamdy Abeer

    2016-01-01

    Full Text Available Mobile applications are becoming an integral part of daily life and of business’s marketing plan. They are helpful in promoting for the business, attracting and retaining customers. Software testing is vital to ensure the delivery of high quality mobile applications that could be accessed across different platforms and meet business and technical requirements. This paper proposes a web based tool, namely Pons, for the distribution of pre-release mobile applications for the purpose of manual testing. Pons facilities building, running, and manually testing Android applications directly in the browser. It gets the developers and end users engaged in testing the applications in one place, alleviates the tester’s burden of installing and maintaining testing environments, and provides a platform for developers to rapidly iterate on the software and integrate changes over time. Thus, it speeds up the pre-release testing process, reduces its cost and increases customer satisfaction.

  8. K West basin isolation barrier leak rate test

    International Nuclear Information System (INIS)

    Whitehurst, R.; McCracken, K.; Papenfuss, J.N.

    1994-01-01

    This document establishes the procedure for performing the acceptance test on the two isolation barriers being installed in K West basin. This acceptance test procedure shall be used to: First establish a basin water loss rate prior to installation of the two isolation barriers between the main basin and the discharge chute in K-Basin West. Second, perform an acceptance test to verify an acceptable leakage rate through the barrier seals

  9. Testing the accelerating moment release (AMR) hypothesis in areas of high stress

    Science.gov (United States)

    Guilhem, Aurélie; Bürgmann, Roland; Freed, Andrew M.; Ali, Syed Tabrez

    2013-11-01

    Several retrospective analyses have proposed that significant increases in moment release occurred prior to many large earthquakes of recent times. However, the finding of accelerating moment release (AMR) strongly depends on the choice of three parameters: (1) magnitude range, (2) area being considered surrounding the events and (3) the time period prior to the large earthquakes. Consequently, the AMR analysis has been criticized as being a posteriori data-fitting exercise with no new predictive power. As AMR has been hypothesized to relate to changes in the state of stress around the eventual epicentre, we compare here AMR results to models of stress accumulation in California. Instead of assuming a complete stress drop on all surrounding fault segments implied by a back-slip stress lobe method, we consider that stress evolves dynamically, punctuated by the occurrence of earthquakes, and governed by the elastic and viscous properties of the lithosphere. We study the seismicity of southern California and extract events for AMR calculations following the systematic approach employed in previous studies. We present several sensitivity tests of the method, as well as grid-search analyses over the region between 1955 and 2005 using fixed magnitude range, radius of the search area and period of time. The results are compared to the occurrence of large events and to maps of Coulomb stress changes. The Coulomb stress maps are compiled using the coseismic stress from all M > 7.0 earthquakes since 1812, their subsequent post-seismic relaxation, and the interseismic strain accumulation. We find no convincing correlation of seismicity rate changes in recent decades with areas of high stress that would support the AMR hypothesis. Furthermore, this indicates limited utility for practical earthquake hazard analysis in southern California, and possibly other regions.

  10. Full scale ambient water flow tests of a 10-inch emergency release coupling for LNG transfer

    NARCIS (Netherlands)

    Putte, L.J. van der; Webber, T.; Bokhorst, E. van; Revell, C.

    2016-01-01

    For LNG transfer in ship-to-ship and ship-to-shore configurations emergency release couplings (F.RC) in combination with loading arms and multi-composite hoses are applied In view of a demand for increasing transfer flow rates in offshore LNG applications a 10-inch ERC has been developed intended

  11. Containment Leakage Rate Testing Program in NPP Krsko

    International Nuclear Information System (INIS)

    Dudas, M.; Heruc, Z.

    2002-01-01

    NPP Krsko adopted new regulations for testing of the reactor building containment as stipulated by 10CFR50 (Code of Federal Regulation) Appendix J, Option B instead of the previous requirement 10CFR50 Appendix J now renamed to 10CFR50 Appendix J, Option A. In the USA a thorough analyses of nuclear power plants reactor building containment testing was conducted. As part of these analyses the test results obtained from testing of various reactor-building containments in the last ten years were reviewed. It was concluded that it would be meaningful to, based on test results historical data, reconsider possibility of redefining testing intervals. The official proposal of such approach was reviewed and approved by the NRC and published in September of 1995 in the FR Vol.60 No.186. Based on directions from 10CFR50 Appendix J, Option B, the new criteria for definition of test intervals were created. Criteria were based upon past performance during testing (Performance-based Requirements) and safety impact. At NPP Krsko, the analyses of the Reactor Building Containment. Integrity Test results was performed . This included test results of the Containment Integrated Leak Rate Testing (CILRT or Type A tests), Containment Isolation Valves Local Leak Rater Tests (Type C tests) and Mechanical and Electrical Penetrations Local Leak Rate tests (Type B tests). In accordance with instructions from NEI 94-01 and based on analyses of test results, NPP Krsko created Containment Leakage Rate Testing Program with the purpose to establish the performance-based definition of test intervals, inspection scope, trending and reporting. Equally, the program gives instructions how to evaluate test results and how to deal with the containment penetration or isolation valve repair contingency. All changes caused with transition from Option A to Option B are marginal to public safety. (author)

  12. Development of test apparatus for fission product release from overheated fuel element

    International Nuclear Information System (INIS)

    Takai, T.; Hirosawa, T.; Funabashi, H.; Miyahara, S.

    1996-01-01

    Evaluation of the source term released to environment under the accident conditions is important to the safety evaluation and design of reactor containment vessel. However, available data related to FBR source term are very limited, especially for the FPs release data from overheated FBR fuel. The present, source term evaluation of FBR is based on assumption from that of LWR. Though, this evaluation is very conservative. Evaluation large scale FBR source term using this method is result in extremely conservative and lead construction of large scale plant becomes doubtful from the viewpoints of cost and safety system. Though, it is necessary to evaluate source term from the realistic and rational scenario considering a characteristic of FBR. Preparation of FPs release experiment from irradiated fuel is going on to investigate the FPs release and transport and to develop the analysis code for in-vessel source term evaluation. Fabrication of this apparatus was started in 1992, and the installation was completed in 1994. This apparatus passed the facility inspection by Science and Technology Agency in March 1995. This apparatus consists of a high frequency induction furnace, thermal gradient tube (TGT), sintered metal filters, cold traps, gas-analyzer, γ-ray spectrometry system and so on. In the experiment, FPs release rate and behavior will be investigated using gamma-ray spectrogram and FP gas analysis. Physical and chemical composition of released FP would be investigated from FPs deposited profiles on TGT. Now, cold experiment using simulant FP materials are conducted. (author)

  13. Measurement of iodine released in a blowdown accident in the HTR-Modul. Final report on flow tests

    International Nuclear Information System (INIS)

    Zentis, A.

    1993-01-01

    A passive measuring device has been designed which consists of several filter cartridges of differnt length, and which is placed into the depressurization channel of the reactor. The dependence of the rate of flow through the filter on the flow rate in the depressurization channel must be known in order to be able to derive from the radioactivity deposited and measured in the filters a value indicating the total amount of iodine released. The report explains the basic principles of design of the instrument and of the experiments, and gives an interpretation of results of the flow tests in the AVA (aerodynamic testing facility) at Interatom. These flow tests have shown that it is feasible to determine the order of magnitude of iodine emissions with the given method and instrument. (orig./HP) [de

  14. Effects of Sediment Chemical Properties on Phosphorus Release Rates in the Sediment-Water Interface of the Steppe Wetlands.

    Science.gov (United States)

    He, Jing; Su, Derong; Lv, Shihai; Diao, Zhaoyan; Xie, Jingjie; Luo, Yan

    2017-11-22

    Rising temperature causes a process of phosphorus release, which can be characterized well using phosphorus release rates (V P ). The objective of the present study was to investigate the major factors affecting sediment phosphorus release rates through a wetland habitat simulation experiment. The results showed that the V P of different wetland sediments were different and changed with the order of W-R (river wetland) > W-L (lake wetland) > W-M (grassy marsh wetland) > W-A (reservoir wetland). The main driving factors which influenced sediment phosphorus flux velocity in the sediment-water interface were sediment B-SO₄ 2- , B-MBN and A-MBP content. Path analysis and determination coefficient analysis indicated the standard multiple regression equation for sediment phosphorus release rates in the sediment-water interface, and each main factor was Y = -0.105 + 0.096X₁ + 0.275X₂ - 0.010X₃ ( r = 0.416, p phosphorus release rates; X₁ is sediment B-SO₄ 2- content; X₂ is sediment B-MBN; and X₃ is sediment A-MBP content. Sediment B-SO₄ 2- , B-MBN and A-MBP content and the interaction between them were the main factors affecting sediment phosphorus release rates in the sediment-water interface. Therefore, these results suggest that soil chemical properties and microbial activities likely play an important role in phosphorus release rates in the sediment-water interface. We hope to provide effective scientific management and control methods for relevant environmental protection departments.

  15. Effects of Sediment Chemical Properties on Phosphorus Release Rates in the Sediment-Water Interface of the Steppe Wetlands

    Directory of Open Access Journals (Sweden)

    Jing He

    2017-11-01

    Full Text Available Rising temperature causes a process of phosphorus release, which can be characterized well using phosphorus release rates (VP. The objective of the present study was to investigate the major factors affecting sediment phosphorus release rates through a wetland habitat simulation experiment. The results showed that the VP of different wetland sediments were different and changed with the order of W–R (river wetland > W–L (lake wetland > W–M (grassy marsh wetland > W–A (reservoir wetland. The main driving factors which influenced sediment phosphorus flux velocity in the sediment–water interface were sediment B-SO42−, B-MBN and A-MBP content. Path analysis and determination coefficient analysis indicated the standard multiple regression equation for sediment phosphorus release rates in the sediment–water interface, and each main factor was Y = −0.105 + 0.096X1 + 0.275X2 − 0.010X3 (r = 0.416, p < 0.01, n = 144, where Y is sediment phosphorus release rates; X1 is sediment B-SO42− content; X2 is sediment B-MBN; and X3 is sediment A-MBP content. Sediment B-SO42−, B-MBN and A-MBP content and the interaction between them were the main factors affecting sediment phosphorus release rates in the sediment–water interface. Therefore, these results suggest that soil chemical properties and microbial activities likely play an important role in phosphorus release rates in the sediment–water interface. We hope to provide effective scientific management and control methods for relevant environmental protection departments.

  16. Effect of tunnel cross section on gas temperatures and heat fluxes in case of large heat release rate

    International Nuclear Information System (INIS)

    Fan, Chuan Gang; Li, Ying Zhen; Ingason, Haukur; Lönnermark, Anders

    2016-01-01

    Highlights: • The effect of tunnel cross section together with ventilation velocity was studied. • Ceiling temperature varies clearly with tunnel height, but little with tunnel width. • Downstream temperature decreases with increasing tunnel dimensions. • HRR is an important factor that influences decay rate of excess gas temperature. • An equation considering both tunnel dimensions and HRR was developed. - Abstract: Tests with liquid and solid fuels in model tunnels (1:20) were performed and analysed in order to study the effect of tunnel cross section (width and height) together with ventilation velocity on ceiling gas temperatures and heat fluxes. The model tunnel was 10 m long with varying width (0.3 m, 0.45 m and 0.6 m) and height (0.25 m and 0.4 m). Test results show that the maximum temperature under the ceiling is a weak function of heat release rate (HRR) and ventilation velocity for cases with HRR more than 100 MW at full scale. It clearly varies with the tunnel height and is a weak function of the tunnel width. With a lower tunnel height, the ceiling is closer to the base of continuous flame zone and the temperatures become higher. Overall, the gas temperature beneath the ceiling decreases with the increasing tunnel dimensions, and increases with the increasing longitudinal ventilation velocity. The HRR is also an important factor that influences the decay rate of excess gas temperature, and a dimensionless HRR integrating HRR and other two key parameters, tunnel cross-sectional area and distance between fuel centre and tunnel ceiling, was introduced to account for the effect. An equation for the decay rate of excess gas temperature, considering both the tunnel dimensions and HRR, was developed. Moreover, a larger tunnel cross-sectional area will lead to a smaller heat flux.

  17. Effects of administration of gonadotropin-releasing hormone at artificial insemination on conception rates in dairy cows.

    Science.gov (United States)

    Shephard, R W; Morton, J M; Norman, S T

    2014-01-10

    A controlled trial investigating the effect on conception of administration of 250 μg of gonadotropin-releasing hormone (GnRH) at artificial insemination (AI) in dairy cows in seasonal or split calving herds was conducted. Time of detection of estrus, body condition, extent of estrous expression, treatment, breed, age and milk production from the most recent herd test of the current lactation was recorded. Cows were tested for pregnancy with fetal aging between 35 and 135 days after AI. Sixteen herds provided 2344 spring-calved cows and 3007 inseminations. Logistic regression adjusting for clustering at herd level was used to examine the effect of treatment for first (2344) and second (579) inseminations separately. For first AI, treatment significantly improved conception rate in cows with milk protein concentrations of 3.75% or greater and for cows with milk protein concentrations between 3.00% and 3.50% and less than 40 days calved; increased conception rate from 41.2% to 53.4%. Treatment reduced conception rates in cows with milk protein concentrations of 2.75% or less. Treating only cows identified as responding positively to treatment (11% of all study cows) was estimated to increase first service conception rate in herds from 48.1% to 49.4%. There was no significant effect of treatment on conception to second AI, nor any significant interactions. These findings indicate that GnRH at AI should be limited to the sub-group cows most likely to respond. The positive effect of GnRH at AI may be mediated through improved oocyte maturation and/or improved luteal function, rather than by reducing AI-to-ovulation intervals. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Standard test method for accelerated leach test for diffusive releases from solidified waste and a computer program to model diffusive, fractional leaching from cylindrical waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides procedures for measuring the leach rates of elements from a solidified matrix material, determining if the releases are controlled by mass diffusion, computing values of diffusion constants based on models, and verifying projected long-term diffusive releases. This test method is applicable to any material that does not degrade or deform during the test. 1.1.1 If mass diffusion is the dominant step in the leaching mechanism, then the results of this test can be used to calculate diffusion coefficients using mathematical diffusion models. A computer program developed for that purpose is available as a companion to this test method (Note 1). 1.1.2 It should be verified that leaching is controlled by diffusion by a means other than analysis of the leach test solution data. Analysis of concentration profiles of species of interest near the surface of the solid waste form after the test is recommended for this purpose. 1.1.3 Potential effects of partitioning on the test results can...

  19. Results of fission product release from intermediate-scale MCCI [molten core-concrete interaction] tests

    International Nuclear Information System (INIS)

    Spencer, B.W.; Thompson, D.H.; Fink, J.K.; Gunther, W.H.; Sehgal, B.R.

    1988-01-01

    A program of reactor-material molten core-concrete interaction (MCCI) tests and related analyses are under way at Argonne National Laboratory under sponsorship of the Electric Power Research Institute (EPRI). The particular objective of these tests is to provide data pertaining to the release of nonvolatile fission products such as La, Ba, and Sr, plus other aerosol materials, from the coupled thermal-hydraulic and chemical processes of the MCCI. The first stages of the program involving small and intermediate-scale tests have been completed. Three small-scale tests (/approximately/5 kg corium) and nine intermediate-scale tests (/approximately/30 kg corium) were performed between September 1985 and September 1987. Real reactor materials were used in these tests. Sustained internal heat generation at nominally 1 kW per kg of melt was provided by direct electrical heating of the corium mixture. MCCI tests were performed with both fully and partially oxidized corium mixtures that contained a variety of nonradioactive materials such as La 2 O 3 , BaO, and SrO to represent fission products. Both limestone/common sand and basaltic concrete basemats were used. The system was instrumented for characterization of the thermal hydraulic, chemical, gas release, and aerosol release processes

  20. Use of phosphorus release batch tests for modelling an EBPR pilot plant

    DEFF Research Database (Denmark)

    Tykesson, E.; Aspegren, H.; Henze, Mogens

    2002-01-01

    The aim of this study was to evaluate how routinely performed phosphorus release tests could be used when modelling enhanced biological phosphorus removal (EBPR) using activated sludge models such as ASM2d. A pilot plant with an extensive analysis programme was used as basis for the simulations...

  1. Gaia Data Release 1. Testing parallaxes with local Cepheids and RR Lyrae stars

    NARCIS (Netherlands)

    Gaia Collaboration, [Unknown; Clementini, G.; Eyer, L.; Ripepi, V.; Marconi, M.; Muraveva, T.; Garofalo, A.; Sarro, L. M.; Palmer, M.; Luri, X.; Molinaro, R.; Rimoldini, L.; Szabados, L.; Musella, I.; Anderson, R. I.; Prusti, T.; de Bruijne, J. H. J.; Brown, A. G. A.; Vallenari, A.; Babusiaux, C.; Bailer-Jones, C. A. L.; Bastian, U.; Biermann, M.; Evans, D. W.; Jansen, F.; Jordi, C.; Klioner, S. A.; Lammers, U.; Lindegren, L.; Mignard, F.; Panem, C.; Pourbaix, D.; Randich, S.; Sartoretti, P.; Siddiqui, H. I.; Soubiran, C.; Valette, V.; van Leeuwen, F.; Walton, N. A.; Aerts, C.; Arenou, F.; Cropper, M.; Drimmel, R.; Høg, E.; Katz, D.; Lattanzi, M. G.; O'Mullane, W.; Grebel, E. K.; Holland, A. D.; Huc, C.; Passot, X.; Perryman, M.; Bramante, L.; Cacciari, C.; Castañeda, J.; Chaoul, L.; Cheek, N.; De Angeli, F.; Fabricius, C.; Guerra, R.; Hernández, J.; Jean-Antoine-Piccolo, A.; Masana, E.; Messineo, R.; Mowlavi, N.; Nienartowicz, K.; Ordóñez-Blanco, D.; Panuzzo, P.; Portell, J.; Richards, P. J.; Riello, M.; Seabroke, G. M.; Tanga, P.; Thévenin, F.; Torra, J.; Els, S. G.; Gracia-Abril, G.; Comoretto, G.; Garcia-Reinaldos, M.; Lock, T.; Mercier, E.; Altmann, M.; Andrae, R.; Astraatmadja, T. L.; Bellas-Velidis, I.; Benson, K.; Berthier, J.; Blomme, R.; Busso, G.; Carry, B.; Cellino, A.; Cowell, S.; Creevey, O.; Cuypers, J.; Davidson, M.; De Ridder, J.; de Torres, A.; Delchambre, L.; Dell'Oro, A.; Ducourant, C.; Frémat, Y.; García-Torres, M.; Gosset, E.; Halbwachs, J.-L.; Hambly, N. C.; Harrison, D. L.; Hauser, M.; Hestroffer, D.; Hodgkin, S. T.; Huckle, H. E.; Hutton, A.; Jasniewicz, G.; Jordan, S.; Kontizas, M.; Korn, A. J.; Lanzafame, A. C.; Manteiga, M.; Moitinho, A.; Muinonen, K.; Osinde, J.; Pancino, E.; Pauwels, T.; Petit, J.-M.; Recio-Blanco, A.; Robin, A. C.; Siopis, C.; Smith, M.; Smith, K. W.; Sozzetti, A.; Thuillot, W.; van Reeven, W.; Viala, Y.; Abbas, U.; Abreu Aramburu, A.; Accart, S.; Aguado, J. J.; Allan, P. M.; Allasia, W.; Altavilla, G.; Álvarez, M. A.; Alves, J.; Andrei, A. H.; Anglada Varela, E.; Antiche, E.; Antoja, T.; Antón, S.; Arcay, B.; Bach, N.; Baker, S. G.; Balaguer-Núñez, L.; Barache, C.; Barata, C.; Barbier, A.; Barblan, F.; Barrado y Navascués, D.; Barros, M.; Barstow, M. A.; Becciani, U.; Bellazzini, M.; Bello García, A.; Belokurov, V.; Bendjoya, P.; Berihuete, A.; Bianchi, L.; Bienaymé, O.; Billebaud, F.; Blagorodnova, N.; Blanco-Cuaresma, S.; Boch, T.; Bombrun, A.; Borrachero, R.; Bouquillon, S.; Bourda, G.; Bragaglia, A.; Breddels, M. A.; Brouillet, N.; Brüsemeister, T.; Bucciarelli, B.; Burgess, P.; Burgon, R.; Burlacu, A.; Busonero, D.; Buzzi, R.; Caffau, E.; Cambras, J.; Campbell, H.; Cancelliere, R.; Cantat-Gaudin, T.; Carlucci, T.; Carrasco, J. M.; Castellani, M.; Charlot, P.; Charnas, J.; Chiavassa, A.; Clotet, M.; Cocozza, G.; Collins, R. S.; Costigan, G.; Crifo, F.; Cross, N. J. G.; Crosta, M.; Crowley, C.; Dafonte, C.; Damerdji, Y.; Dapergolas, A.; David, P.; David, M.; De Cat, P.; de Felice, F.; de Laverny, P.; De Luise, F.; De March, R.; de Souza, R.; Debosscher, J.; del Pozo, E.; Delbo, M.; Delgado, A.; Delgado, H. E.; Di Matteo, P.; Diakite, S.; Distefano, E.; Dolding, C.; Dos Anjos, S.; Drazinos, P.; Durán, J.; Dzigan, Y.; Edvardsson, B.; Enke, H.; Evans, N. W.; Eynard Bontemps, G.; Fabre, C.; Fabrizio, M.; Falcão, A. J.; Farràs Casas, M.; Federici, L.; Fedorets, G.; Fernández-Hernández, J.; Fernique, P.; Fienga, A.; Figueras, F.; Filippi, F.; Findeisen, K.; Fonti, A.; Fouesneau, M.; Fraile, E.; Fraser, M.; Fuchs, J.; Gai, M.; Galleti, S.; Galluccio, L.; Garabato, D.; García-Sedano, F.; Garralda, N.; Gavras, P.; Gerssen, J.; Geyer, R.; Gilmore, G.; Girona, S.; Giuffrida, G.; Gomes, M.; González-Marcos, A.; González-Núñez, J.; González-Vidal, J. J.; Granvik, M.; Guerrier, A.; Guillout, P.; Guiraud, J.; Gúrpide, A.; Gutiérrez-Sánchez, R.; Guy, L. P.; Haigron, R.; Hatzidimitriou, D.; Haywood, M.; Heiter, U.; Helmi, A.; Hobbs, D.; Hofmann, W.; Holl, B.; Holland, G.; Hunt, J. A. S.; Hypki, A.; Icardi, V.; Irwin, M.; Jevardat de Fombelle, G.; Jofré, P.; Jonker, P. G.; Jorissen, A.; Julbe, F.; Karampelas, A.; Kochoska, A.; Kohley, R.; Kolenberg, K.; Kontizas, E.; Koposov, S. E.; Kordopatis, G.; Koubsky, P.; Krone-Martins, A.; Kudryashova, M.; Bachchan, R. K.; Lacoste-Seris, F.; Lanza, A. F.; Lavigne, J.-B.; Le Poncin-Lafitte, C.; Lebreton, Y.; Lebzelter, T.; Leccia, S.; Leclerc, N.; Lecoeur-Taibi, I.; Lemaitre, V.; Lenhardt, H.; Leroux, F.; Liao, S.; Licata, E.; Lindstrøm, H. E. P.; Lister, T. A.; Livanou, E.; Lobel, A.; Löffler, W.; López, M.; Lorenz, D.; MacDonald, I.; Magalhães Fernandes, T.; Managau, S.; Mann, R. G.; Mantelet, G.; Marchal, O.; Marchant, J. M.; Marinoni, S.; Marrese, P. M.; Marschalkó, G.; Marshall, D. J.; Martín-Fleitas, J. M.; Martino, M.; Mary, N.; Matijevič, G.; McMillan, P. J.; Messina, S.; Michalik, D.; Millar, N. R.; Miranda, B. M. H.; Molina, D.; Molinaro, M.; Molnár, L.; Moniez, M.; Montegriffo, P.; Mor, R.; Mora, A.; Morbidelli, R.; Morel, T.; Morgenthaler, S.; Morris, D.; Mulone, A. F.; Narbonne, J.; Nelemans, G.; Nicastro, L.; Noval, L.; Ordénovic, C.; Ordieres-Meré, J.; Osborne, P.; Pagani, C.; Pagano, I.; Pailler, F.; Palacin, H.; Palaversa, L.; Parsons, P.; Pecoraro, M.; Pedrosa, R.; Pentikäinen, H.; Pichon, B.; Piersimoni, A. M.; Pineau, F.-X.; Plachy, E.; Plum, G.; Poujoulet, E.; Prša, A.; Pulone, L.; Ragaini, S.; Rago, S.; Rambaux, N.; Ramos-Lerate, M.; Ranalli, P.; Rauw, G.; Read, A.; Regibo, S.; Reylé, C.; Ribeiro, R. A.; Riva, A.; Rixon, G.; Roelens, M.; Romero-Gómez, M.; Rowell, N.; Royer, F.; Ruiz-Dern, L.; Sadowski, G.; Sagristà Sellés, T.; Sahlmann, J.; Salgado, J.; Salguero, E.; Sarasso, M.; Savietto, H.; Schultheis, M.; Sciacca, E.; Segol, M.; Segovia, J. C.; Segransan, D.; Shih, I.-C.; Smareglia, R.; Smart, R. L.; Solano, E.; Solitro, F.; Sordo, R.; Soria Nieto, S.; Souchay, J.; Spagna, A.; Spoto, F.; Stampa, U.; Steele, I. A.; Steidelmüller, H.; Stephenson, C. A.; Stoev, H.; Suess, F. F.; Süveges, M.; Surdej, J.; Szegedi-Elek, E.; Tapiador, D.; Taris, F.; Tauran, G.; Taylor, M. B.; Teixeira, R.; Terrett, D.; Tingley, B.; Trager, S. C.; Turon, C.; Ulla, A.; Utrilla, E.; Valentini, G.; van Elteren, A.; Van Hemelryck, E.; van Leeuwen, M.; Varadi, M.; Vecchiato, A.; Veljanoski, J.; Via, T.; Vicente, D.; Vogt, S.; Voss, H.; Votruba, V.; Voutsinas, S.; Walmsley, G.; Weiler, M.; Weingrill, K.; Wevers, T.; Wyrzykowski, Ł.; Yoldas, A.; Žerjal, M.; Zucker, S.; Zurbach, C.; Zwitter, T.; Alecu, A.; Allen, M.; Allende Prieto, C.; Amorim, A.; Anglada-Escudé, G.; Arsenijevic, V.; Azaz, S.; Balm, P.; Beck, M.; Bernstein, H.-H.; Bigot, L.; Bijaoui, A.; Blasco, C.; Bonfigli, M.; Bono, G.; Boudreault, S.; Bressan, A.; Brown, S.; Brunet, P.-M.; Bunclark†, P.; Buonanno, R.; Butkevich, A. G.; Carret, C.; Carrion, C.; Chemin, L.; Chéreau, F.; Corcione, L.; Darmigny, E.; de Boer, K. S.; de Teodoro, P.; de Zeeuw, P. T.; Delle Luche, C.; Domingues, C. D.; Dubath, P.; Fodor, F.; Frézouls, B.; Fries, A.; Fustes, D.; Fyfe, D.; Gallardo, E.; Gallegos, J.; Gardiol, D.; Gebran, M.; Gomboc, A.; Gómez, A.; Grux, E.; Gueguen, A.; Heyrovsky, A.; Hoar, J.; Iannicola, G.; Isasi Parache, Y.; Janotto, A.-M.; Joliet, E.; Jonckheere, A.; Keil, R.; Kim, D.-W.; Klagyivik, P.; Klar, J.; Knude, J.; Kochukhov, O.; Kolka, I.; Kos, J.; Kutka, A.; Lainey, V.; LeBouquin, D.; Liu, C.; Loreggia, D.; Makarov, V. V.; Marseille, M. G.; Martayan, C.; Martinez-Rubi, O.; Massart, B.; Meynadier, F.; Mignot, S.; Munari, U.; Nguyen, A.-T.; Nordlander, T.; O'Flaherty, K. S.; Ocvirk, P.; Olias Sanz, A.; Ortiz, P.; Osorio, J.; Oszkiewicz, D.; Ouzounis, A.; Park, P.; Pasquato, E.; Peltzer, C.; Peralta, J.; Péturaud, F.; Pieniluoma, T.; Pigozzi, E.; Poels†, J.; Prat, G.; Prod'homme, T.; Raison, F.; Rebordao, J. M.; Risquez, D.; Rocca-Volmerange, B.; Rosen, S.; Ruiz-Fuertes, M. I.; Russo, F.; Serraller Vizcaino, I.; Short, A.; Siebert, A.; Silva, H.; Sinachopoulos, D.; Slezak, E.; Soffel, M.; Sosnowska, D.; Straižys, V.; ter Linden, M.; Terrell, D.; Theil, S.; Tiede, C.; Troisi, L.; Tsalmantza, P.; Tur, D.; Vaccari, M.; Vachier, F.; Valles, P.; Van Hamme, W.; Veltz, L.; Virtanen, J.; Wallut, J.-M.; Wichmann, R.; Wilkinson, M. I.; Ziaeepour, H.; Zschocke, S.

    2017-01-01

    Context. Parallaxes for 331 classical Cepheids, 31 Type II Cepheids, and 364 RR Lyrae stars in common between Gaia and the Hipparcos and Tycho-2 catalogues are published in Gaia Data Release 1 (DR1) as part of the Tycho-Gaia Astrometric Solution (TGAS). Aims: In order to test these first parallax

  2. A reproducible accelerated in vitro release testing method for PLGA microspheres.

    Science.gov (United States)

    Shen, Jie; Lee, Kyulim; Choi, Stephanie; Qu, Wen; Wang, Yan; Burgess, Diane J

    2016-02-10

    The objective of the present study was to develop a discriminatory and reproducible accelerated in vitro release method for long-acting PLGA microspheres with inner structure/porosity differences. Risperidone was chosen as a model drug. Qualitatively and quantitatively equivalent PLGA microspheres with different inner structure/porosity were obtained using different manufacturing processes. Physicochemical properties as well as degradation profiles of the prepared microspheres were investigated. Furthermore, in vitro release testing of the prepared risperidone microspheres was performed using the most common in vitro release methods (i.e., sample-and-separate and flow through) for this type of product. The obtained compositionally equivalent risperidone microspheres had similar drug loading but different inner structure/porosity. When microsphere particle size appeared similar, porous risperidone microspheres showed faster microsphere degradation and drug release compared with less porous microspheres. Both in vitro release methods investigated were able to differentiate risperidone microsphere formulations with differences in porosity under real-time (37 °C) and accelerated (45 °C) testing conditions. Notably, only the accelerated USP apparatus 4 method showed good reproducibility for highly porous risperidone microspheres. These results indicated that the accelerated USP apparatus 4 method is an appropriate fast quality control tool for long-acting PLGA microspheres (even with porous structures). Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Erythrocyte Sedimentation Rate (ESR): MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Erythrocyte Sedimentation Rate (ESR); p. 267– ...

  4. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  5. Development and testing of the circumvaginal muscles rating scale.

    Science.gov (United States)

    Worth, A M; Dougherty, M C; McKey, P L

    1986-01-01

    The purpose of this research was to develop an instrument for clinical assessment of the circumvaginal muscles (CVM), to test the reliability of the instrument, and to correlate sample characteristics with this instrument. The 9-point CVM Rating Scale is based on four components: pressure, duration, muscle ribbing, and position of the examiner's finger during examination. Reliability of the CVM Rating Scale was ascertained by use of interrater and test-retest reliability. Interrater reliability was tested on two separate occasions, N = 10, rho = 0.6, p less than .04; N = 10, rho = 0.7, p less than .05. A test-retest sequence was conducted 10 days apart, N = 10, rho = 0.9, p less than .003. Results from these tests indicated that the CVM Rating Scale is a reliable instrument for assessing CVM. A convenience sample of 30 women, aged 18-37, in good general health was tested, using the CVM Rating Scale. Women with a history of pelvic floor reconstructive surgery were excluded. A significant positive correlation between self-reported orgasm and the CVM Rating Scale total scores was found, chi 2 = 7.5, p less than .02. No significant correlations were found between age, race, parity, episiotomy, or self-reported Kegel exercises and the CVM Rating Scale total scores. The scale is a cost-effective, time-efficient, systematic assessment, accessible in clinical settings.

  6. Testing IH Instrumentation: Analysis of 1996-1998 Tank Ventilation Data in Terms of Characterizing a Transient Release

    International Nuclear Information System (INIS)

    Droppo, James G.

    2004-01-01

    An analysis is conducted of the 1996-1998 Hanford tank ventilation studies of average ventilation rates to help define characteristics of shorter term releases. This effort is being conducted as part of the design of tests of Industrial Hygiene's (IH) instrumentation ability to detect transient airborne plumes from tanks using current deployment strategies for tank operations. This analysis has improved our understanding of the variability of hourly average tank ventilation processes. However, the analysis was unable to discern the relative importance of emissions due to continuous releases and short-duration bursts of material. The key findings are as follows: (1) The ventilation of relatively well-sealed, passively ventilated tanks appears to be driven by a combination of pressure, buoyancy, and wind influences. The results of a best-fit analysis conducted with a single data set provide information on the hourly emission variability that IH instrumentation will need to detect. (2) Tank ventilation rates and tank emission rates are not the same. The studies found that the measured infiltration rates for a single tank are often a complex function of air exchanges between tanks and air exchanges with outdoor air. This situation greatly limits the usefulness of the ventilation data in defining vapor emission rates. (3) There is no evidence in the data to discern if the routine tank vapor releases occur over a short time (i.e., a puff) or over an extended time (i.e., continuous releases). Based on this analysis of the tank ventilation studies, it is also noted that (1) the hourly averaged emission peaks from the relatively well-sealed passively-vented tanks (such as U-103) are not a simple function of one meteorological parameter--but the peaks often are the result of the coincidence of temporal maximums in pressure, temperature, and wind influences and (2) a mechanistic combination modeling approach and/or field studies may be necessary to understand the short

  7. Broadband Acoustic Resonance Dissolution Spectroscopy (BARDS): A rapid test for enteric coating thickness and integrity of controlled release pellet formulations.

    Science.gov (United States)

    Alfarsi, Anas; Dillon, Amy; McSweeney, Seán; Krüse, Jacob; Griffin, Brendan; Devine, Ken; Sherry, Patricia; Henken, Stephan; Fitzpatrick, Stephen; Fitzpatrick, Dara

    2018-04-12

    There are no rapid dissolution based tests for determining coating thickness, integrity and drug concentration in controlled release pellets either during production or post-production. The manufacture of pellets requires several coating steps depending on the formulation. The sub-coating and enteric coating steps typically take up to six hours each followed by additional drying steps. Post production regulatory dissolution testing also takes up to six hours to determine if the batch can be released for commercial sale. The thickness of the enteric coating is a key factor that determines the release rate of the drug in the gastro-intestinal tract. Also, the amount of drug per unit mass decreases with increasing thickness of the enteric coating. In this study, the coating process is tracked from start to finish on an hourly basis by taking samples of pellets during production and testing those using BARDS (Broadband Acoustic Resonance Dissolution Spectroscopy). BARDS offers a rapid approach to characterising enteric coatings with measurements based on reproducible changes in the compressibility of a solvent due to the evolution of air during dissolution. This is monitored acoustically via associated changes in the frequency of induced acoustic resonances. A steady state acoustic lag time is associated with the disintegration of the enteric coatings in basic solution. This lag time is pH dependent and is indicative of the rate at which the coating layer dissolves. BARDS represents a possible future surrogate test for conventional USP dissolution testing as its data correlates directly with the thickness of the enteric coating, its integrity and also with the drug loading as validated by HPLC. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  9. Effects of health information exchange adoption on ambulatory testing rates.

    Science.gov (United States)

    Ross, Stephen E; Radcliff, Tiffany A; Leblanc, William G; Dickinson, L Miriam; Libby, Anne M; Nease, Donald E

    2013-01-01

    To determine the effects of the adoption of ambulatory electronic health information exchange (HIE) on rates of laboratory and radiology testing and allowable charges. Claims data from the dominant health plan in Mesa County, Colorado, from 1 April 2005 to 31 December 2010 were matched to HIE adoption data on the provider level. Using mixed effects regression models with the quarter as the unit of analysis, the effect of HIE adoption on testing rates and associated charges was assessed. Claims submitted by 306 providers in 69 practices for 34 818 patients were analyzed. The rate of testing per provider was expressed as tests per 1000 patients per quarter. For primary care providers, the rate of laboratory testing increased over the time span (baseline 1041 tests/1000 patients/quarter, increasing by 13.9 each quarter) and shifted downward with HIE adoption (downward shift of 83, prates or imputed charges in either provider group. Ambulatory HIE adoption is unlikely to produce significant direct savings through reductions in rates of testing. The economic benefits of HIE may reside instead in other downstream outcomes of better informed, higher quality care.

  10. 77 FR 2606 - Pipeline Safety: Random Drug Testing Rate

    Science.gov (United States)

    2012-01-18

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2012-0004] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...

  11. 75 FR 9018 - Pipeline Safety: Random Drug Testing Rate

    Science.gov (United States)

    2010-02-26

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2010-0034] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...

  12. Evaluation of Ocimum basilicum L. seed mucilage as rate controlling matrix for sustained release of propranolol HCl

    Directory of Open Access Journals (Sweden)

    Majid Saeedi

    2015-01-01

    Full Text Available Polysaccharide mucilage derived from the seeds of Ocimum basilicum L. (family Lamiaceae was investigated for use in matrix formulations containing propranolol hydrochloride. Basil mucilage was extracted and several tablets were formulated. The effect of mucilage on drug release rate was evaluated in comparison with tablets containing two kinds of hydroxypropyl methylcellulose (HPMC K4M and HPMC K100M as standard polymer. The release data were fitted to several models for kinetic evaluation. The results showed that hardness decreased and friability of tablets increased as the concentration of mucilage increased. The rate of release of propranolol HCl from O. basilicm mucilage matrices was mainly controlled by the drug: mucilage ratio. Drug release was slower from the HPMC K4M and HPMCK100M containing tablets compared to the mucilage containing matrices than the drug release from matrices containing O. basilicum seed mucilage in similar ratios.  Formulations containing O. basilicm mucilage were found to exhibit suitable release pattern. The results of kinetic analysis showed that in tablets containing O. basilicm mucilage the highest correlation coefficient was achieved with the zero order model. The swelling and erosion studies revealed that, as the proportion of mucilage in tablets was increased, there was a corresponding increase in percent swelling and a decrease in percent erosion of tablets.

  13. Influence of the rate of conversion of HT and HTO on projected radiation doses from release of molecular tritium

    International Nuclear Information System (INIS)

    Jacobs, D.G.; Easterly, C.E.; Phillips, J.E.

    1979-01-01

    Releases of tritium in the past have been largely in the form of tritiated water, and the projected radiation doses could be estimated by assuming tritium behaviour to parallel that of water. There is increasing interest in potential releases of tritium in the form of HT because of significant recent advances in fusion reactor research. Several recent studies have shown that bacteria containing the enzyme hydrogenase can catalyse the conversion of HT to HTO at rates several orders of magnitude faster than the rates measured in atmospheric systems. Rates of conversion in the soil have been combined with estimates of rates of permeation of HT into the soil and with global and local models depicting tritium transport and cycling. The results suggest that for the expected conversion rates, the impact on projected radiation doses should be relatively minor. (author)

  14. 75 FR 79308 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2011

    Science.gov (United States)

    2010-12-20

    ...-11213, Notice No. 14] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2011... random testing positive rates were .037 percent for drugs and .014 percent for alcohol. Because the... effective December 20, 2010. FOR FURTHER INFORMATION CONTACT: Lamar Allen, Alcohol and Drug Program Manager...

  15. 77 FR 75896 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013

    Science.gov (United States)

    2012-12-26

    ...-11213, Notice No. 16] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013...., Washington, DC 20590, (telephone 202-493- 1342); or Kathy Schnakenberg, FRA Alcohol/Drug Program Specialist... from FRA's Management Information System, the rail industry's random drug testing positive rate has...

  16. Effects of Time-Release Caffeine Containing Supplement on Metabolic Rate, Glycerol Concentration and Performance

    Directory of Open Access Journals (Sweden)

    Adam M. Gonzalez, Jay R. Hoffman, Adam J. Wells, Gerald T. Mangine, Jeremy R. Townsend, Adam R. Jajtner, Ran Wang, Amelia A. Miramonti, Gabriel J. Pruna, Michael B. LaMonica, Jonathan D. Bohner, Mattan W. Hoffman, Leonardo P. Oliveira, David H. Fukuda, Maren S. Fragala, Jeffrey R. Stout

    2015-06-01

    Full Text Available This study compared caffeine pharmacokinetics, glycerol concentrations, metabolic rate, and performance measures following ingestion of a time-release caffeine containing supplement (TR-CAF versus a regular caffeine capsule (CAF and a placebo (PL. Following a double-blind, placebo-controlled, randomized, cross-over design, ten males (25.9 ± 3.2 y who regularly consume caffeine ingested capsules containing either TR-CAF, CAF, or PL. Blood draws and performance measures occurred at every hour over an 8-hour period. Plasma caffeine concentrations were significantly greater (p < 0.05 in CAF compared to TR-CAF during hours 2-5 and significantly greater (p = 0.042 in TR-CAF compared to CAF at hour 8. There were no significant differences between trials in glycerol concentrations (p = 0.86 or metabolic measures (p = 0.17-0.91. Physical reaction time was significantly improved for CAF at hour 5 (p=0.01 compared to PL. Average upper body reaction time was significantly improved for CAF and TR-CAF during hours 1-4 (p = 0.04 and p = 0.01, respectively and over the 8-hour period (p = 0.04 and p = 0.001, respectively compared to PL. Average upper body reaction time was also significantly improved for TR-CAF compared to PL during hours 5-8 (p = 0.004. TR-CAF and CAF showed distinct pharmacokinetics yielding modest effects on reaction time, yet did not alter glycerol concentration, metabolic measures, or other performance measures.

  17. Update: Tests confirm no radioactivity release to environment from IAEA Seibersdorf Lab after 3 August incident

    International Nuclear Information System (INIS)

    2008-01-01

    Full text: Independent analysis has confirmed that there was no release of radioactive material to the environment following an incident at the IAEA's Seibersdorf Laboratory on 3 August. The test results were provided by the Austrian Research Centers (ARC), from analysis of soil, plant and water samples collected from outside the IAEA's Laboratories in Seibersdorf, where the incident occurred. The radiation protection experts of the ARC confirmed the initial findings from the laboratory's automatic monitoring system which indicated that there had been no release of radioactivity to the environment. Since the incident, constant air monitoring near the laboratory, undertaken by the IAEA, has also provided no evidence of any radioactive contamination. A tiny amount of plutonium contained in an acid solution spilled from five small glass vials when one of them burst after a build up of pressure in it. The vials were stored in a secure steel safe. In total there was less than one gram of plutonium in the five vials. The material was in the laboratory for scientific reference purposes and virtually all of the contamination was confined within the steel walled safe. As previously reported, the automatic alarm was triggered when highly sensitive detectors of the continuous air monitoring system identified minor amounts of radioactive aerosols in the storage room containing the safe. The air contamination was trapped entirely in the filters of the ventilation system. No one was working in the laboratory at the time of the accident, which occurred at 02:31. The IAEA emergency response team promptly secured and sealed off the windowless storage room. An investigation into the circumstances and causes of the incident is still underway. In the meantime the first stage of the clean-up of the storage room was successfully completed on Friday, 22 August. According to the IAEA's nuclear regulator's assessment of the incident, the lab's safety systems worked properly and

  18. Update: Tests confirm no radioactivity release to environment from IAEA Seibersdorf Lab after 3 August incident

    International Nuclear Information System (INIS)

    2008-01-01

    Full text: Independent analysis has confirmed that there was no release of radioactive material to the environment following an incident at the IAEA's Seibersdorf Laboratory on 3 August. The test results were provided by the Austrian Research Centers (ARC), from analysis of soil, plant and water samples collected from outside the IAEA's Laboratories in Seibersdorf, where the incident occurred. The radiation protection experts of the ARC confirmed the initial findings from the laboratory's automatic monitoring system which indicated that there had been no release of radioactivity to the environment. Since the incident, constant air monitoring near the laboratory, undertaken by the IAEA, has also provided no evidence of any radioactive contamination. A tiny amount of plutonium contained in an acid solution spilled from five small glass vials when one of them burst after a build up of pressure in it. The vials were stored in a secure steel safe. In total there was less than one gram of plutonium in the five vials. The material was in the laboratory for scientific reference purposes and virtually all of the contamination was confined within the steel walled safe. As previously reported, the automatic alarm was triggered when highly sensitive detectors of the continuous air monitoring system identified minor amounts of radioactive aerosols in the storage room containing the safe. The air contamination was trapped entirely in the filters of the ventilation system. No one was working in the laboratory at the time of the accident, which occurred at 02:31. The IAEA emergency response team promptly secured and sealed off the windowless storage room. An investigation into the circumstances and causes of the incident is still underway. In the meantime the first stage of the clean-up of the storage room was successfully completed on Friday, 22 August. According to the IAEA's nuclear regulator's assessment of the incident, the lab's safety systems worked properly and

  19. Combined approach to reduced duration integrated leakage rate testing

    International Nuclear Information System (INIS)

    Galanti, P.J.

    1987-01-01

    Even though primary reactor containment allowable leakage rates are expressed in weight percent per day of contained air, engineers have been attempting to define acceptable methods to test in < 24 h as long as these tests have been performed. The reasons to reduce testing duration are obvious, because time not generating electricity is time not generating revenue for the utilities. The latest proposed revision to 10CFR50 Appendix J, concerning integrated leakage rate testing (ILRTs), was supplemented with a draft regulatory guide proposing yet another method. This paper proposes a method that includes elements of currently accepted concepts for short duration testing with a standard statistical check for criteria acceptance. Following presentation of the method, several cases are presented showing the results of these combined criteria

  20. Standardized Testing Practices: Effect on Graduation and NCLEX® Pass Rates.

    Science.gov (United States)

    Randolph, Pamela K

    The use standardized testing in pre-licensure nursing programs has been accompanied by conflicting reports of effective practices. The purpose of this project was to describe standardized testing practices in one states' nursing programs and discover if the use of a cut score or oversight of remediation had any effect on (a) first time NCLEX® pass rates, (b) on-time graduation (OTG) or (c) the combination of (a) and (b). Administrators of 38 nursing programs in one Southwest state were sent surveys; surveys were returned by 34 programs (89%). Survey responses were compared to each program's NCLEX pass rate and on-time graduation rate; t-tests were conducted for significant differences associated with a required minimum score (cut score) and oversight of remediation. There were no significant differences in NCLEX pass or on-time graduation rates related to establishment of a cut score. There was a significant difference when the NCLEX pass rate and on-time graduation rate were combined (Outcome Index "OI") with significantly higher program outcomes (P=.02.) for programs without cut-scores. There were no differences associated with faculty oversight of remediation. The results of this study do not support establishment of a cut-score when implementing a standardized testing. Copyright © 2016. Published by Elsevier Inc.

  1. MCNP(TM) Release 6.1.1 beta: Creating and Testing the Code Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Cox, Lawrence J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Casswell, Laura [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-06-12

    This report documents the preparations for and testing of the production release of MCNP6™1.1 beta through RSICC at ORNL. It addresses tests on supported operating systems (Linux, MacOSX, Windows) with the supported compilers (Intel, Portland Group and gfortran). Verification and Validation test results are documented elsewhere. This report does not address in detail the overall packaging of the distribution. Specifically, it does not address the nuclear and atomic data collection, the other included software packages (MCNP5, MCNPX and MCNP6) and the collection of reference documents.

  2. Guinea pig maximization tests with formaldehyde releasers. Results from two laboratories

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Boman, A; Hamann, K

    1984-01-01

    The guinea pig maximization test was used to evaluate the sensitizing potential of formaldehyde and 6 formaldehyde releasers (Forcide 78, Germall 115, Grotan BK, Grotan OX, KM 200 and Preventol D2). The tests were carried out in 2 laboratories (Copenhagen and Stockholm), and although we intended...... the procedures to be the same, discrepancies were observed, possibly due to the use of different animal strains, test concentrations and vehicles. The sensitizing potential was in general found to be stronger in Stockholm compared to Copenhagen: formaldehyde sensitized 50% of the guinea pigs in Copenhagen and 95...

  3. Uniaxial tension test on Rubber at constant true strain rate

    Directory of Open Access Journals (Sweden)

    Sourne H.L.

    2012-08-01

    Full Text Available Elastomers are widely used for damping parts in different industrial contexts because of their remarkable dissipation properties. Indeed, they can undergo severe mechanical loading conditions, i.e., high strain rates and large strains. Nevertheless, the mechanical response of these materials can vary from purely rubber-like to glassy depending on the strain rate undergone. Classically, uniaxial tension tests are made in order to find a relation between the stress and the strain in the material at various strain rates. However, even if the strain rate is searched to be constant, it is the nominal strain rate that is considered. Here we develop a test at constant true strain rate, i.e. the strain rate that is experienced by the material. In order to do such a test, the displacement imposed by the machine is an exponential function of time. This test has been performed with a high speed hydraulic machine for strain rates between 0.01/s and 100/s. A specific specimen has been designed, yielding a uniform strain field (and so a uniform stress field. Furthermore, an instrumented aluminum bar has been used to take into account dynamic effects in the measurement of the applied force. A high speed camera enables the determination of strain in the sample using point tracking technique. Using this method, the stress-strain curve of a rubber-like material during a loading-unloading cycle has been determined, up to a stretch ratio λ = 2.5. The influence of the true strain rate both on stiffness and on dissipation of the material is then discussed.

  4. Determination of area reduction rate by continuous ball indentation test

    International Nuclear Information System (INIS)

    Zou, Bin; Guan, Kai Shu; Wu, Sheng Bao

    2016-01-01

    Rate of area reduction is an important mechanical property to appraise the plasticity of metals, which is always obtained from the uniaxial tensile test. A methodology is proposed to determine the area reduction rate by continuous ball indentation test technique. The continuum damage accumulation theory has been adopted in this work to identify the failure point in the indentation. The corresponding indentation depth of this point can be obtained and used to estimate the area reduction rate. The local strain limit criterion proposed in the ASME VIII-2 2007 alternative rules is also adopted in this research to convert the multiaxial strain of indentation test to uniaxial strain of tensile test. The pile-up and sink-in phenomenon which can affect the result significantly is also discussed in this paper. This method can be useful in engineering practice to evaluate the material degradation under severe working condition due to the non-destructive nature of ball indentation test. In order to validate the method, continuous ball indentation test is performed on ferritic steel 16MnR and ASTM (A193B16), then the results are compared with that got from the traditional uniaxial tensile test.

  5. Large scale high strain-rate tests of concrete

    Directory of Open Access Journals (Sweden)

    Kiefer R.

    2012-08-01

    Full Text Available This work presents the stages of development of some innovative equipment, based on Hopkinson bar techniques, for performing large scale dynamic tests of concrete specimens. The activity is centered at the recently upgraded HOPLAB facility, which is basically a split Hopkinson bar with a total length of approximately 200 m and with bar diameters of 72 mm. Through pre-tensioning and suddenly releasing a steel cable, force pulses of up to 2 MN, 250 μs rise time and 40 ms duration can be generated and applied to the specimen tested. The dynamic compression loading has first been treated and several modifications in the basic configuration have been introduced. Twin incident and transmitter bars have been installed with strong steel plates at their ends where large specimens can be accommodated. A series of calibration and qualification tests has been conducted and the first real tests on concrete cylindrical specimens of 20cm diameter and up to 40cm length have commenced. Preliminary results from the analysis of the recorded signals indicate proper Hopkinson bar testing conditions and reliable functioning of the facility.

  6. Development and evaluation of a new prototype P&T system to determine in-heading gas release rate.

    CSIR Research Space (South Africa)

    Van Zyl, FJ

    2001-11-01

    Full Text Available In order to quantify the potential methane hazard in underground coal mines, it is necessary to determine the in-seam methane content and an expected gas release rate during production. Various methods for estimating this have been proposed, ranging...

  7. Reduced rates of controlled-release fertilizer lower potential nitrogen leaching from a Wisconsin bare-root tree nursery

    Science.gov (United States)

    Ryosuke Fujinuma; Nick J. Balster; Hyung-Kyung. Lee

    2011-01-01

    Controlled-release fertilizer (CRF) typically increases nitrogen (N) fertilizer uptake and lowers N lost from the rooting zone via leaching. However, questions remain as to whether lower rates of CRF could further increase this efficiency, especially in sandy bare-root nurseries in Wisconsin. We hypothesized that: 1) a reduced CRF application at 60 percent of the...

  8. Isopleths of surface concentration and surface exposure rate due to a radioactive cloud released from a stack

    International Nuclear Information System (INIS)

    Kobayashi, Hideo; Yabuta, Hajimu; Katagiri, Hiroshi; Obata, Kazuichi; Kokubu, Morinobu

    1982-03-01

    Various calculations are made to estimate the distributions of concentration and γ-exposure rate due to a radioactive cloud released from a point source to the atmosphere. In this report, the isopleths of concentration and γ-exposure rate which were calculated are given in graphs to enable rapid prediction of the influence of released radioactive material in the emergency situation. Recently there are facilities which are equipped with a system to display the calculation results on CRT; but such practice is rather rare. By placing the calculated isopleths of reduction scale 1/25000 or 1/50000 on the usual map, any facilities without the CRT system can readily estimate the influence of an accidental release. The graphs of isopleths are given with the release height (11 values of 0 to 200 m at about 20 m intervals) and the atmospheric stability (6 classes) as parameters. Calculations of γ-exposure rates were made using the computer code GAMPUL developed by T. Hayashi and T. Shiraishi. In the calculation of radioactive concentrations and γ-exposure rates, the vertical diffusion depths, σsub(z), exceeding 1000 m are taken to be 1000 m according to the Meteorological Guide for the Safety Analysis of Power Reactor (J.AEC). The comparison between with and without this limitation in σsub(z) is made in the case of downwind axial surface distributions. (author)

  9. Comparison of the Heat Release Rate from the Mass Loss Calorimeter to the Cone Calorimeter for Wood-based Materials

    Science.gov (United States)

    Laura E. Hasburgh; Robert H. White; Mark A. Dietenberger; Charles R. Boardman

    2015-01-01

    There is a growing demand for material properties to be used as inputs in fi re behavior models designed to address building fire safety. This comparative study evaluates using the mass loss calorimeter as an alternative to the cone calorimeter for obtaining heat release rates of wood-based materials. For this study, a modified mass loss calorimeter utilized an...

  10. Integrated leak rate test of the FFTF [Fast Flux Test Facility] containment vessel

    International Nuclear Information System (INIS)

    Grygiel, M.L.; Davis, R.H.; Polzin, D.L.; Yule, W.D.

    1987-04-01

    The third integrated leak rate test (ILRT) performed at the Fast Flux Test Facility (FFTF) demonstrated that effective leak rate measurements could be obtained at a pressure of 2 psig. In addition, innovative data reduction methods demonstrated the ability to accurately account for diurnal variations in containment pressure and temperature. Further development of methods used in this test indicate significant savings in the time and effort required to perform an ILRT on Liquid Metal Reactor Systems with consequent reduction in test costs

  11. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  12. High rate tests of the LHCb RICH Upgrade system

    CERN Multimedia

    Blago, Michele Piero

    2016-01-01

    One of the biggest challenges for the upgrade of the LHCb RICH detectors from 2020 is to readout the photon detectors at the full 40 MHz rate of the LHC proton-proton collisions. A test facility has been setup at CERN with the purpose to investigate the behaviour of the Multi Anode PMTs, which have been proposed for the upgrade, and their readout electronics at high trigger rates. The MaPMTs are illuminated with a monochromatic laser that can be triggered independently of the readout electronics. A first series of tests, including threshold scans, is performed at low trigger rates (20 kHz) for both the readout and the laser with the purpose to characterise the behaviour of the system under test. Then the trigger rate is increased in two separate steps. First the MaPMTs are exposed to high illumination by triggering the pulsed laser at a high (20 MHz) repetition rate while the DAQ is readout at the same low rate as before. In this way the performance of the MaPMTs and the attached electronics can be evaluated ...

  13. Isopleths of surface air concentration and surface air kerma rate due to a radioactive cloud released from a stack (3)

    International Nuclear Information System (INIS)

    Tachibana, Haruo; Kikuchi, Masamitsu; Sekita, Tsutomu; Yamaguchi, Takenori

    2004-06-01

    This report is a revised edition of 'Isopleths of Surface Air Concentration and Surface Air Absorbed Dose Rate due to a Radioactive Cloud Released from a Stack(II) '(JAERI-M 90-206) and based on the revised Nuclear Safety Guidelines reflected the ICRP1990 Recommendation. Characteristics of this report are the use of Air Karma Rate (Gy/h) instead of Air Absorbed Dose Rate (Gy/h), and the record of isopleths of surface air concentration and surface air karma rate on CD-ROM. These recorded data on CD-ROM can be printed out on paper and/or pasted on digital map by personal computer. (author)

  14. Closure report for CAU No. 450: Historical UST release sites, Nevada Test Site. Volume 2

    International Nuclear Information System (INIS)

    1997-09-01

    This report addresses the closure of 11 historical underground storage tank release sites within various areas of the Nevada Test Site. This report contains remedial verification of the soil sample analytical results for the following: Area 11 Tweezer facility; Area 12 boiler house; Area 12 service station; Area 23 bypass yard; Area 23 service station; Area 25 power house; Area 25 tech. services building; Area 25 tech. operations building; Area 26 power house; and Area 27 boiler house

  15. The design and testing of a memory metal actuated boom release mechanism

    Science.gov (United States)

    Powley, D. G.; Brook, G. B.

    1979-01-01

    A boom latch and release mechanism was designed, manufactured and tested, based on a specification for the ISEE-B satellite mechanism. From experimental results obtained, it is possible to calculate the energy available and the operating torques which can be achieved from a torsional shape memory element in terms of the reversible strain induced by prior working. Some guidelines to be followed when designing mechanisms actuated by shape memory elements are included.

  16. Gaia Data Release 1. Testing the parallaxes with local Cepheids and RR Lyrae stars

    OpenAIRE

    Gaia Collaboration; Clementini, G.; Eyer, L.; Ripepi, V.; Marconi, M.; Muraveva, T.; Garofalo, A.; Sarro, L. M.; Palmer, M.; Luri, X.; Molinaro, R.; Rimoldini, L.; Szabados, L.; Musella, I.; Anderson, R. I.

    2017-01-01

    Context. Parallaxes for 331 classical Cepheids, 31 Type II Cepheids, and 364 RR Lyrae stars in common between Gaia and the HIPPARCOS and Tycho-2 catalogues are published in Gaia Data Release 1 (DR1) as part of the Tycho-Gaia Astrometric Solution (TGAS). Aims. In order to test these first parallax measurements of the primary standard candles of the cosmological distance ladder, which involve astrometry collected by Gaia during the initial 14 months of science operation, we compared them with l...

  17. Performance characteristics of UV imaging instrumentation for diffusion, dissolution and release testing studies

    DEFF Research Database (Denmark)

    Jensen, Sabrine S; Jensen, Henrik; Goodall, David M

    2016-01-01

    UV imaging is capable of providing spatially and temporally resolved absorbance measurements, which is highly beneficial in drug diffusion, dissolution and release testing studies. For optimal planning and design of experiments, knowledge about the capabilities and limitations of the imaging syst...... mainly to depend on collimation of light, the light path, the positioning of the object relative to the line of 100μm fibres which forms the light source, and the distance of the object from the sensor surface....

  18. Effective Anti-miRNA Oligonucleotides Show High Releasing Rate of MicroRNA from RNA-Induced Silencing Complex.

    Science.gov (United States)

    Ariyoshi, Jumpei; Matsuyama, Yohei; Kobori, Akio; Murakami, Akira; Sugiyama, Hiroshi; Yamayoshi, Asako

    2017-10-01

    MicroRNAs (miRNAs) regulate gene expression by forming RNA-induced silencing complexes (RISCs) and have been considered as promising therapeutic targets. MiRNA is an essential component of RISC for the modulation of gene expression. Therefore, the release of miRNA from RISC is considered as an effective method for the inhibition of miRNA functions. In our previous study, we reported that anti-miRNA oligonucleotides (AMOs), which are composed of the 2'-O-methyl (2'-OMe) RNA, could induce the release of miRNA from RISC. However, the mechanisms underlying the miRNA-releasing effects of chemically modified AMOs, which are conventionally used as anti-cancer drugs, are still unclear. In this study, we investigated the relationship between the miRNA releasing rate from RISC and the inhibitory effect on RISC activity (IC 50 ) using conventional chemically modified AMOs. We demonstrated that the miRNA-releasing effects of AMOs are directly proportional to the IC 50 values, and AMOs, which have an ability to promote the release of miRNA from RISC, can effectively inhibit RISC activity in living cells.

  19. LHC-rate beam test of CMS pixel barrel modules

    International Nuclear Information System (INIS)

    Erdmann, W.; Hoermann, Ch.; Kotlinski, D.; Horisberger, R.; Kaestli, H. Chr.; Gabathuler, K.; Bertl, W.; Meier, B.; Langenegger, U.; Trueeb, P.; Rohe, T.

    2007-01-01

    Modules for the CMS pixel barrel detector have been operated in a high rate pion beam at PSI in order to verify under LHC-like conditions the final module design for the production. The test beam provided charged particle rates up to 10 8 cm -2 s -1 over the full module area. Bunch structure and randomized high trigger rates simulated realistic operation. A four layer telescope made of single pixel readout chip assemblies provided tracking needed for the determination of the modules hit reconstruction efficiency. The performance of the modules has been shown to be adequate for the CMS pixel barrel

  20. Accelerated testing for cosmic soft-error rate

    International Nuclear Information System (INIS)

    Ziegler, J.F.; Muhlfeld, H.P.; Montrose, C.J.; Curtis, H.W.; O'Gorman, T.J.; Ross, J.M.

    1996-01-01

    This paper describes the experimental techniques which have been developed at IBM to determine the sensitivity of electronic circuits to cosmic rays at sea level. It relates IBM circuit design and modeling, chip manufacture with process variations, and chip testing for SER sensitivity. This vertical integration from design to final test and with feedback to design allows a complete picture of LSI sensitivity to cosmic rays. Since advanced computers are designed with LSI chips long before the chips have been fabricated, and the system architecture is fully formed before the first chips are functional, it is essential to establish the chip reliability as early as possible. This paper establishes techniques to test chips that are only partly functional (e.g., only 1Mb of a 16Mb memory may be working) and can establish chip soft-error upset rates before final chip manufacturing begins. Simple relationships derived from measurement of more than 80 different chips manufactured over 20 years allow total cosmic soft-error rate (SER) to be estimated after only limited testing. Comparisons between these accelerated test results and similar tests determined by ''field testing'' (which may require a year or more of testing after manufacturing begins) show that the experimental techniques are accurate to a factor of 2

  1. Size-fractionated characterization and quantification of nanoparticle release rates from a consumer spray product containing engineered nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Hagendorfer, Harald, E-mail: Harald.Hagendorfer@empa.c [EMPA, Swiss Federal Laboratories for Materials Testing and Research (Switzerland); Lorenz, Christiane, E-mail: Christiane.Lorenz@chem.ethz.c [ETHZ, Swiss Federal Institute of Technology Zurich (Switzerland); Kaegi, Ralf, E-mail: Ralf.Kaegi@eawag.ch; Sinnet, Brian, E-mail: Brian.Sinnet@eawag.c [EAWAG, Swiss Federal Institute of Aquatic Science and Technology (Switzerland); Gehrig, Robert, E-mail: Robert.Gehrig@empa.c [EMPA, Swiss Federal Laboratories for Materials Testing and Research (Switzerland); Goetz, Natalie V., E-mail: Natalie.vonGoetz@chem.ethz.ch; Scheringer, Martin, E-mail: Martin.Scheringer@chem.ethz.c [ETHZ, Swiss Federal Institute of Technology Zurich (Switzerland); Ludwig, Christian, E-mail: Christian.Ludwig@psi.c [PSI, Paul Scherrer Institue (Switzerland); Ulrich, Andrea, E-mail: Andrea.Ulrich@empa.c [EMPA, Swiss Federal Laboratories for Materials Testing and Research (Switzerland)

    2010-09-15

    This study describes methods developed for reliable quantification of size- and element-specific release of engineered nanoparticles (ENP) from consumer spray products. A modified glove box setup was designed to allow controlled spray experiments in a particle-minimized environment. Time dependence of the particle size distribution in a size range of 10-500 nm and ENP release rates were studied using a scanning mobility particle sizer (SMPS). In parallel, the aerosol was transferred to a size-calibrated electrostatic TEM sampler. The deposited particles were investigated using electron microscopy techniques in combination with image processing software. This approach enables the chemical and morphological characterization as well as quantification of released nanoparticles from a spray product. The differentiation of solid ENP from the released nano-sized droplets was achieved by applying a thermo-desorbing unit. After optimization, the setup was applied to investigate different spray situations using both pump and gas propellant spray dispensers for a commercially available water-based nano-silver spray. The pump spray situation showed no measurable nanoparticle release, whereas in the case of the gas spray, a significant release was observed. From the results it can be assumed that the homogeneously distributed ENP from the original dispersion grow in size and change morphology during and after the spray process but still exist as nanometer particles of size <100 nm. Furthermore, it seems that the release of ENP correlates with the generated aerosol droplet size distribution produced by the spray vessel type used. This is the first study presenting results concerning the release of ENP from spray products.

  2. Size-fractionated characterization and quantification of nanoparticle release rates from a consumer spray product containing engineered nanoparticles

    International Nuclear Information System (INIS)

    Hagendorfer, Harald; Lorenz, Christiane; Kaegi, Ralf; Sinnet, Brian; Gehrig, Robert; Goetz, Natalie V.; Scheringer, Martin; Ludwig, Christian; Ulrich, Andrea

    2010-01-01

    This study describes methods developed for reliable quantification of size- and element-specific release of engineered nanoparticles (ENP) from consumer spray products. A modified glove box setup was designed to allow controlled spray experiments in a particle-minimized environment. Time dependence of the particle size distribution in a size range of 10-500 nm and ENP release rates were studied using a scanning mobility particle sizer (SMPS). In parallel, the aerosol was transferred to a size-calibrated electrostatic TEM sampler. The deposited particles were investigated using electron microscopy techniques in combination with image processing software. This approach enables the chemical and morphological characterization as well as quantification of released nanoparticles from a spray product. The differentiation of solid ENP from the released nano-sized droplets was achieved by applying a thermo-desorbing unit. After optimization, the setup was applied to investigate different spray situations using both pump and gas propellant spray dispensers for a commercially available water-based nano-silver spray. The pump spray situation showed no measurable nanoparticle release, whereas in the case of the gas spray, a significant release was observed. From the results it can be assumed that the homogeneously distributed ENP from the original dispersion grow in size and change morphology during and after the spray process but still exist as nanometer particles of size <100 nm. Furthermore, it seems that the release of ENP correlates with the generated aerosol droplet size distribution produced by the spray vessel type used. This is the first study presenting results concerning the release of ENP from spray products.

  3. Helium release rates and ODH calculations from RHIC magnet cooling line failure

    Energy Technology Data Exchange (ETDEWEB)

    Liaw, C.J.; Than, Y.; Tuozzolo, J.

    2011-03-28

    A catastrophic failure of the magnet cooling lines, similar to the LHC superconducting bus failure incident, could discharge cold helium into the RHIC tunnel and cause an Oxygen Deficiency Hazard (ODH) problem. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the insulating vacuum volumes and discharging via the reliefs into the RHIC tunnel, had been developed. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces are included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Results, including helium discharge rates, helium inventory loss, and the resulting oxygen concentration in the RHIC tunnel area, are reported. Good agreement had been achieved when comparing the simulation results, a RHIC sector depressurization test measurement, and some simple analytical calculations.

  4. Radionuclides release from re-irradiated fuel under high temperature and pressure conditions. Gamma-ray measurements of VEGA-5 test

    Energy Technology Data Exchange (ETDEWEB)

    Hidaka, Akihide; Kudo, Tamotsu; Nakamura, Takehiko; Kanazawa, Toru; Kiuchi, Toshio; Uetsuka, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    The VEGA (Verification Experiments of radionuclides Gas/Aerosol release) program is being performed at JAERI to clarify mechanisms of radionuclides release from irradiated fuel during severe accidents and to improve source term predictability. The fifth VEGA-5 test was conducted in January 2002 to confirm the reproducibility of decrease in cesium release under elevated pressure that was observed in the VEGA-2 test and to investigate the release behavior of short-life radionuclides. The PWR fuel of 47 GWd/tU after about 8.2 years of cooling was re-irradiated at Nuclear Safety Research Reactor (NSRR) for 8 hours before the heat-up test. After that, the two pellets of 10.9 g without cladding were heated up to about 2,900 K at 1.0 MPa under the inert He condition. The experiment reconfirmed the decrease in cesium release rate under the elevated pressure. The release data on short-life radionuclides such as Ru-103, Ba-140 and Xe-133 that have never been observed in the previous VEGA tests without re-irradiation was obtained using the {gamma} ray measurement. (author)

  5. Dam Breach Release of Non-Cohesive Sediments: Channel Response and Recovery Rates

    Science.gov (United States)

    Collins, M. J.; Boardman, G.; Banks, W.; Andrews, M.; Conlon, M.; Dillow, J. J. A.; Gellis, A.; Lowe, S.; McClain, S.; Miller, A. J.; Snyder, N. P.; Wilcock, P. R.

    2014-12-01

    Dam removals featuring unchecked releases of non-cohesive sediments are excellent opportunities to learn more about stream channel response to abrupt increases in bed material supply that can occur deliberately or by natural processes like landslides and volcanic eruptions. Understanding channel response to sediment pulses, including response rates, is essential because human uses of river channels and floodplains are impacted by these events as are aquatic habitats. We had the opportunity to study a dam removal site at the Simkins Dam in Maryland, USA, that shares many important geophysical attributes of another well-studied dam removal in the humid northeast United States [Merrimack Village Dam, New Hampshire; Pearson et al., 2011]. The watershed sizes are the same order of magnitude (102 km2), and at both sites relatively low head dams were removed (~ 3-4 m) and ~60,000 m3 of dominantly sand-sized sediments discharged to low-gradient reaches immediately downstream. Analyzing four years of repeat morphometry and bed sediment grain size surveys at the Simkins site on the Patapsco River, as well as continuous discharge and suspended sediment gaging data, we clearly document a two-phase response in the upstream reach as described by Pearson et al. [2011] for their New Hampshire site and noted at other dam removals [e.g., Major et al., 2012]. In the early phase, approximately 50% of the impounded sediment mass was eroded rapidly over a period of about three months when flows were very modest (Figure 1). After incision to base level and channel widening in the former impoundment, a second phase began when further erosion depended on floods large enough to access impounded sediments more distant from the newly-formed channel. We also found important differences in the upstream responses at the Maryland and New Hampshire sites that appear to be related to valley type (non-glaciated versus glaciated, respectively). Response variances immediately downstream between the

  6. 75 FR 66057 - Waybill Data Released in Three-Benchmark Rail Rate Proceedings

    Science.gov (United States)

    2010-10-27

    ... (CSX Transp. II), 584 F.3d 1076 (DC Cir. 2009), the Board modified its simplified rail rate guidelines...- Benchmark approach for smaller rail rate disputes. The Three-Benchmark method compares a challenged rate of...: The RSAM and R/VC >180 benchmarks. See Rate Guidelines--Non-Coal Proceedings, (Rate Guidelines) 1 S.T...

  7. Development and validation of a dissolution test for diltiazem hydrochloride in immediate release capsules

    Directory of Open Access Journals (Sweden)

    Taciane Ferreira Mendonça

    2011-01-01

    Full Text Available This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

  8. Effective Rating Scale Development for Speaking Tests: Performance Decision Trees

    Science.gov (United States)

    Fulcher, Glenn; Davidson, Fred; Kemp, Jenny

    2011-01-01

    Rating scale design and development for testing speaking is generally conducted using one of two approaches: the measurement-driven approach or the performance data-driven approach. The measurement-driven approach prioritizes the ordering of descriptors onto a single scale. Meaning is derived from the scaling methodology and the agreement of…

  9. 21 CFR 864.6700 - Erythrocyte sedimentation rate test.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Erythrocyte sedimentation rate test. 864.6700 Section 864.6700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6700 Erythrocyte...

  10. Framed bit error rate testing for 100G ethernet equipment

    DEFF Research Database (Denmark)

    Rasmussen, Anders; Ruepp, Sarah Renée; Berger, Michael Stübert

    2010-01-01

    rate. As the need for 100 Gigabit Ethernet equipment rises, so does the need for equipment, which can properly test these systems during development, deployment and use. This paper presents early results from a work-in-progress academia-industry collaboration project and elaborates on the challenges...

  11. Private sector tuberculosis prevention in the US: Characteristics associated with interferon-gamma release assay or tuberculin skin testing.

    Science.gov (United States)

    Stockbridge, Erica L; Miller, Thaddeus L; Carlson, Erin K; Ho, Christine

    2018-01-01

    To determine whether latent tuberculosis infection risk factors are associated with an increased likelihood of latent tuberculosis infection testing in the US private healthcare sector. A national sample of medical and pharmacy claims representing services rendered January 2011 through December 2013 for 3,997,986 commercially insured individuals in the US who were 0 to 64 years of age. We used multivariable logistic regression models to determine whether TB/LTBI risk factors were associated with an increased likelihood of Interferon-Gamma Release Assay (IGRA) or Tuberculin Skin Test (TST) testing in the private sector. 4.31% (4.27-4.34%) received at least one TST/IGRA test between 2011 and 2013 while 1.69% (1.67-1.72%) received a TST/IGRA test in 2013. Clinical risk factors associated with a significantly increased likelihood of testing included HIV, immunosuppressive therapy, exposure to tuberculosis, a history of tuberculosis, diabetes, tobacco use, end stage renal disease, and alcohol use disorder. Other significant variables included gender, age, asthma, the state tuberculosis rate, population density, and percent of foreign-born persons in a county. Private sector TST/IGRA testing is not uncommon and testing varies with clinical risk indicators. Thus, the private sector can be a powerful resource in the fight against tuberculosis. Analyses of administrative data can inform how best to leverage private sector healthcare toward tuberculosis prevention activities.

  12. On the Ni-Ion release rate from surfaces of binary NiTi shape memory alloys

    Science.gov (United States)

    Ševčíková, Jana; Bártková, Denisa; Goldbergová, Monika; Kuběnová, Monika; Čermák, Jiří; Frenzel, Jan; Weiser, Adam; Dlouhý, Antonín

    2018-01-01

    The study is focused on Ni-ion release rates from NiTi surfaces exposed in the cell culture media and human vascular endothelial cell (HUVEC) culture environments. The NiTi surface layers situated in the depth of 70 μm below a NiTi oxide scale are affected by interactions between the NiTi alloys and the bio-environments. The finding was proved with use of inductively coupled plasma mass spectrometry and electron microscopy experiments. As the exclusive factor controlling the Ni-ion release rates was not only thicknesses of the oxide scale, but also the passivation depth, which was two-fold larger. Our experimental data strongly suggested that some other factors, in addition to the Ni concentration in the oxide scale, admittedly hydrogen soaking deep below the oxide scale, must be taken into account in order to rationalize the concentrations of Ni-ions released into the bio-environments. The suggested role of hydrogen as the surface passivation agent is also in line with the fact that the Ni-ion release rates considerably decrease in NiTi samples that were annealed in controlled hydrogen atmospheres prior to bio-environmental exposures.

  13. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  14. Groundwater flow analysis and dose rate estimates from releases to wells at a coastal site

    Energy Technology Data Exchange (ETDEWEB)

    Kattilakoski, E.; Suolanen, V. [VTT Energy, Espoo (Finland)

    2000-09-01

    {sup 3}/a. Due to the placing of the shallow wells in the discharge areas, the dilution calculated in the shallow well was shown to be close to that calculated in the deep well. In conservative considerations the value around 90 000 m{sup 3}/a can be regarded as a representative expectation value of the effective dilution of the well. This dilution volume value was also suggested by the most realistic modelling approach of the groundwater flow analysis. It was used as basis when calculating the nuclide specific dose conversion factors (DCF's) for the drinking water pathway. The DCF's were calculated for unit release rates (1 Bq/a) and the assumed water consumption rate was 2 litres/day. (orig.)

  15. Efficient field testing for load rating railroad bridges

    Science.gov (United States)

    Schulz, Jeffrey L.; Brett C., Commander

    1995-06-01

    As the condition of our infrastructure continues to deteriorate, and the loads carried by our bridges continue to increase, an ever growing number of railroad and highway bridges require load limits. With safety and transportation costs at both ends of the spectrum. the need for accurate load rating is paramount. This paper describes a method that has been developed for efficient load testing and evaluation of short- and medium-span bridges. Through the use of a specially-designed structural testing system and efficient load test procedures, a typical bridge can be instrumented and tested at 64 points in less than one working day and with minimum impact on rail traffic. Various techniques are available to evaluate structural properties and obtain a realistic model. With field data, a simple finite element model is 'calibrated' and its accuracy is verified. Appropriate design and rating loads are applied to the resulting model and stress predictions are made. This technique has been performed on numerous structures to address specific problems and to provide accurate load ratings. The merits and limitations of this approach are discussed in the context of actual examples of both rail and highway bridges that were tested and evaluated.

  16. Site Release Report for C-Well Pipeline, UE-25 Large Rocks Test Site, and 29 GSF Test Pits

    International Nuclear Information System (INIS)

    K.E. Rasmuson

    2002-01-01

    The U.S. Department of Energy has implemented a program to reclaim lands disturbed by site characterization at Yucca Mountain. Long term goals of the program are to re-establish processes on disturbed sites that will lead to self-sustaining plant communities. The Biological Opinion for Yucca Mountain Site Characterization Studies required that the U.S. Department of Energy develop a Reclamation Standards and Monitoring Plan to evaluate the success of reclamation efforts. According to the Reclamation Standards and Monitoring Plan, reclaimed sites will be monitored periodically, remediated if necessary, and eventually compared to an appropriate reference area to determine whether reclamation goals have been achieved and the site can be released from further monitoring. Plant cover, density, and species richness (success parameters) on reclaimed sites are compared to 60 percent of the values (success criteria) for the same parameters on the reference area. Small sites (less than 0.1 ha) are evaluated for release using qualitative methods while large sites (greater than 0.1 ha) are evaluated using quantitative methods. In the summer of 2000, 31 small sites reclaimed in 1993 and 1994 were evaluated for reclamation success and potential release from further monitoring. Plant density, cover, and species richness were estimated on the C-Well Pipeline, UE-25 Large Rocks test site, and 29 ground surface facility test pits. Evidence of erosion, reproduction and natural recruitment, exotic species abundance, and animal use (key attributes) also were recorded for each site and used in success evaluations. The C-Well Pipeline and ground surface facility test pits were located in a ''Larrea tridentata - Ephedra nevadensis'' vegetation association while the UE-25 Large Rocks test site was located in an area dominated by ''Coleogyne ramosissima and Ephedra nevadensis''. Reference areas in the same vegetation associations with similar slope and aspect were chosen for comparison to

  17. Site Release Reports for C-Well Pipeline, UE-25 Large Rocks Test Site, and 29 GSF Test Pits

    Energy Technology Data Exchange (ETDEWEB)

    K.E. Rasmuson

    2002-04-02

    The U.S. Department of Energy has implemented a program to reclaim lands disturbed by site characterization at Yucca Mountain. Long term goals of the program are to re-establish processes on disturbed sites that will lead to self-sustaining plant communities. The Biological Opinion for Yucca Mountain Site Characterization Studies required that the U.S. Department of Energy develop a Reclamation Standards and Monitoring Plan to evaluate the success of reclamation efforts. According to the Reclamation Standards and Monitoring Plan, reclaimed sites will be monitored periodically, remediated if necessary, and eventually compared to an appropriate reference area to determine whether reclamation goals have been achieved and the site can be released from further monitoring. Plant cover, density, and species richness (success parameters) on reclaimed sites are compared to 60 percent of the values (success criteria) for the same parameters on the reference area. Small sites (less than 0.1 ha) are evaluated for release using qualitative methods while large sites (greater than 0.1 ha) are evaluated using quantitative methods. In the summer of 2000, 31 small sites reclaimed in 1993 and 1994 were evaluated for reclamation success and potential release from further monitoring. Plant density, cover, and species richness were estimated on the C-Well Pipeline, UE-25 Large Rocks test site, and 29 ground surface facility test pits. Evidence of erosion, reproduction and natural recruitment, exotic species abundance, and animal use (key attributes) also were recorded for each site and used in success evaluations. The C-Well Pipeline and ground surface facility test pits were located in a ''Larrea tridentata - Ephedra nevadensis'' vegetation association while the UE-25 Large Rocks test site was located in an area dominated by ''Coleogyne ramosissima and Ephedra nevadensis''. Reference areas in the same vegetation associations with similar slope

  18. Thermal ramp rate effects on mixed-oxide fuel swelling/gas release

    International Nuclear Information System (INIS)

    Hinman, C.A.; Randklev, E.H.

    1979-01-01

    Macroscopic swelling behavior of PNL-10 was compared to that of PNL-2 fuel and it was found that the swelling-threshold behavior is similar for similar thermal conditions. Transient fission gas release for the PNL-10 fuel is very similar to that observed for the PNL-2 fuel for similar thermal conditions

  19. Smart integrated containment leakage rate test system using wireless communication

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hwan; Lee, Sang Yong; Kim, Jung Sun; Kim, Gun Soo; Kim, Jong Myeong; Ahn, Jong Han [Research and Development Center, Ulsan (Korea, Republic of)

    2012-10-15

    Integrated Leakage Rate Test (ILRT) is the important test the confidentiality and integrity of the containment building, which is the last barrier when Design basis accidents (DBA) of Nuclear Power plant occur. Since the result of this test is the basis to guarantee the safety of nuclear power plants, the test process, test procedure, and the test equipment are required to have high reliability. The test devices previously used have been products of VOLUMERTRICS and GRAFTEL of USA. These devices have been inconvenient to calibrate and use. Thus improved devices needed to be developed to remove the inconveniences, to verify the safety of Korean nuclear power plants with Korea's own technology, and to secure core technology. A new leak test system was developed by domestic technology for that purpose and needed to be verified. In this paper, technical details of the newly developed easy to use and highly reliable measuring test device, which is in operation at the nuclear power plant sites, will be introduced. State of art technology was applied to the device to address the shortcomings of previous US made devices and the difficulties to use on site.

  20. Uptake and release of glucose by the human kidney. Postabsorptive rates and responses to epinephrine.

    Science.gov (United States)

    Stumvoll, M; Chintalapudi, U; Perriello, G; Welle, S; Gutierrez, O; Gerich, J

    1995-11-01

    Despite ample evidence that the kidney can both produce and use appreciable amounts of glucose, the human kidney is generally regarded as playing a minor role in glucose homeostasis. This view is based on measurements of arteriorenal vein glucose concentrations indicating little or no net release of glucose. However, inferences from net balance measurements do not take into consideration the simultaneous release and uptake of glucose by the kidney. Therefore, to assess the contribution of release and uptake of glucose by the human kidney to overall entry and removal of plasma glucose, we used a combination of balance and isotope techniques to measure renal glucose net balance, fractional extraction, uptake and release as well as overall plasma glucose appearance and disposal in 10 normal volunteers under basal postabsorptive conditions and during a 3-h epinephrine infusion. In the basal postabsorptive state, there was small but significant net output of glucose by the kidney (66 +/- 22 mumol.min-1, P = 0.016). However, since renal glucose fractional extraction averaged 2.9 +/- 0.3%, there was considerable renal glucose uptake (2.3 +/- 0.2 mumol.kg-1.min-1) which accounted for 20.2 +/- 1.7% of systemic glucose disposal (11.4 +/- 0.5 mumol.kg-1.min-1). Renal glucose release (3.2 +/- 0.2 mumol.kg-1.min-1) accounted for 27.8 +/- 2.1% of systemic glucose appearance (11.4 +/- 0.5 mumol.kg-1.min-1). Epinephrine infusion, which increased plasma epinephrine to levels observed during hypoglycemia (3722 +/- 453 pmol/liter) increased renal glucose release nearly twofold (5.2 +/- 0.5 vs 2.8 +/- 0.1 mol.kg-1.min-1, P = 0.01) so that at the end of the infusion, renal glucose release accounted for 40.3 +/- 5.5% of systemic glucose appearance and essentially all of the increase in systemic glucose appearance. These observations suggest an important role for the human kidney in glucose homeostasis.

  1. Monitoring the hydrolyzation of aspirin during the dissolution testing for aspirin delayed-release tablets with a fiber-optic dissolution system

    Directory of Open Access Journals (Sweden)

    Yan Wang

    2012-10-01

    Full Text Available The purpose of this study was to investigate the hydrolyzation of aspirin during the process of dissolution testing for aspirin delayed-release tablets. Hydrolysis product of salicylic acid can result in adverse effects and affect the determination of dissolution rate assaying. In this study, the technique of differential spectra was employed, which made it possible to monitor the dissolution testing in situ. The results showed that the hydrolyzation of aspirin made the percentage of salicylic acid exceed the limit of free salicylic acid (4.0, and the hydrolyzation may affect the quality detection of aspirin delayed-release tablets. Keywords: Aspirin delayed-release tablets, Drug dissolution test, Fiber-optic dissolution system, UV–vis spectrum

  2. High Strain Rate Testing of Welded DOP-26 Iridium

    Energy Technology Data Exchange (ETDEWEB)

    Schneibel, J. H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Miller, R. G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Carmichael, C. A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Fox, E. E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ulrich, G. B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); George, E. P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    The iridium alloy DOP-26 is used to produce Clad Vent Set cups that protect the radioactive fuel in radioisotope thermoelectric generators (RTGs) which provide electric power for spacecraft and rovers. In a previous study, the tensile properties of DOP-26 were measured over a wide range of strain rates and temperatures and reported in ORNL/TM-2007/81. While that study established the properties of the base material, the fabrication of the heat sources requires welding, and the mechanical properties of welded DOP-26 have not been extensively characterized in the past. Therefore, this study was undertaken to determine the mechanical properties of DOP-26 specimens containing a transverse weld in the center of their gage sections. Tensile tests were performed at room temperature, 750, 900, and 1090°C and engineering strain rates of 1×10-3 and 10 s-1. Room temperature testing was performed in air, while testing at elevated temperatures was performed in a vacuum better than 1×10-4 Torr. The welded specimens had a significantly higher yield stress, by up to a factor of ~2, than the non-welded base material. The yield stress did not depend on the strain rate except at 1090°C, where it was slightly higher for the faster strain rate. The ultimate tensile stress, on the other hand, was significantly higher for the faster strain rate at temperatures of 750°C and above. At 750°C and above, the specimens deformed at 1×10-3 s-1 showed pronounced necking resulting sometimes in perfect chisel-edge fracture. The specimens deformed at 10 s-1 exhibited this fracture behavior only at the highest test temperature, 1090°C. Fracture occurred usually in the fusion zone of the weld and was, in most cases, primarily intergranular.

  3. 75 FR 1547 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2010

    Science.gov (United States)

    2010-01-12

    ...-11213, Notice No. 13] RIN 2130-AA81 Alcohol and Drug Testing: Determination of Minimum Random Testing... percent for alcohol. Because the industry-wide random drug testing positive rate has remained below 1.0... effective upon publication. FOR FURTHER INFORMATION CONTACT: Lamar Allen, Alcohol and Drug Program Manager...

  4. Testing the Control of Mineral Supply Rates on Chemical Erosion Rates in the Klamath Mountains

    Science.gov (United States)

    West, N.; Ferrier, K.

    2016-12-01

    The relationship between rates of chemical erosion and mineral supply is central to many problems in Earth science, including how tightly Earth's climate should be coupled to tectonics, how strongly nutrient supply to soils and streams depends on soil production, and how much lithology affects landscape evolution. Despite widespread interest in this relationship, there remains no consensus on how closely coupled chemical erosion rates should be to mineral supply rates. To address this, we have established a network of field sites in the Klamath Mountains along a latitudinal transect that spans an expected gradient in mineral supply rates associated with the geodynamic response to the migration of the Mendocino Triple Junction. Here, we present new measurements of regolith geochemistry and topographic analyses that will be compared with cosmogenic 10Be measurements to test hypotheses about supply-limited and kinetically-limited chemical erosion on granodioritic ridgetops. Previous studies in this area suggest a balance between rock uplift rates and basin wide erosion rates, implying the study ridgetops may have adjusted to an approximate steady state. Preliminary data are consistent with a decrease in chemical depletion fraction (CDF) with increasing ridgetop curvature. To the extent that ridgetop curvature reflects ridgetop erosion rates, this implies that chemical erosion rates at these sites are influenced by both mineral supply rates and dissolution kinetics.

  5. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  6. LOFT/LP-FP-2, Loss of Fluid Test, Fission Product Release from Fuel

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The eighth OECD LOFT experiment was conducted on 7 March 1985. It was the second of the two experiments to be performed in the LOFT facility with intentional release of fission products. Its principal objectives were to determine the fission product release from the fuel during a severe fuel damage scenario and the subsequent transport of these fission products in a predominantly vapor/aerosol environment. This was the largest severe fuel damage experiment ever conducted, and serves as an important benchmark between smaller scale tests and the TMI-2 accident. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  7. Optical Methods For Automatic Rating Of Engine Test Components

    Science.gov (United States)

    Pritchard, James R.; Moss, Brian C.

    1989-03-01

    In recent years, increasing commercial and legislative pressure on automotive engine manufacturers, including increased oil drain intervals, cleaner exhaust emissions and high specific power outputs, have led to increasing demands on lubricating oil performance. Lubricant performance is defined by bench engine tests run under closely controlled conditions. After test, engines are dismantled and the parts rated for wear and accumulation of deposit. This rating must be consistently carried out in laboratories throughout the world in order to ensure lubricant quality meeting the specified standards. To this end, rating technicians evaluate components, following closely defined procedures. This process is time consuming, inaccurate and subject to drift, requiring regular recalibration of raters by means of international rating workshops. This paper describes two instruments for automatic rating of engine parts. The first uses a laser to determine the degree of polishing of the engine cylinder bore, caused by the reciprocating action of piston. This instrument has been developed to prototype stage by the NDT Centre at Harwell under contract to Exxon Chemical, and is planned for production within the next twelve months. The second instrument uses red and green filtered light to determine the type, quality and position of deposit formed on the piston surfaces. The latter device has undergone feasibility study, but no prototype exists.

  8. High rate loading tests and impact tests of concrete and reinforcement

    International Nuclear Information System (INIS)

    Takeda, J.I.; Tachikawa, H.; Fujimoto, K.

    1982-01-01

    The responses of reinforced concrete structural members and structures subjected to impact or impulsive loadings are affected by the behavior of constituent concrete and reinforcement which are the synthesis of the rate effects and the contribution of propagating stress waves of them. The rate effects and the contribution of stress waves do not have the same tendency in the variation of magnitude of them with speed of impact or impulsive loadings. Therefore the rate effects, mentioned above, should be obtained by the tests minimized the effect of stress waves (high rate loading test). This paper deals with the testing techniques with high rate loadings and impact, and also reports the main results of these tests. (orig.) [de

  9. Formulation and in-vitro evaluation of directly compressed controlled release matrices of Losartan Potassium using Ethocel Grade 100 as rate retarding agent.

    Science.gov (United States)

    Khan, Kamran Ahmad; Khan, Gul Majid; Zeeshan Danish, Muhammad; Akhlaq; Khan, Haroon; Rehman, Fazal; Mehsud, Saifullah

    2015-12-30

    Current study was aimed to develop 200mg controlled release matrix tablets of Losartan Potassium using Ethocel 100 Premium and Ethocel 100 FP Premium as rate controlling polymer. In-vitro studies were performed according to USP Method-I in phosphate buffer (PH 6.8) using pharma test dissolution apparatus. The temperature of the dissolution medium was kept constant at 37±0.5°C at 100rpm. Flow properties, physical quality control tests, effect of polymer size and drug-to-polymers ratios were studied using different kinetics models such as 1st-order, zero-order, Hixon Crowell model, Highuchi model and Power law. Difference factor f1 and similarity factor f2 were applied for dissolution profiles against Cardaktin® tablets used as a reference formulation. The matrices with polymer ethocel 100 FP Premiums have prolonged the drug release rate as compared to polymer ethocel 100 Premiums. The n values matrices with polymer ethocel grade 100 ranged from 0.603 to 0.857 indicating that the drug release occurred by anomalous non fickian diffusion kinetics while then value of reference Cardaktin® tablet was measured as 0.125 indicating that these tablets do not follow power law. The dissolution profiles of test formulations were different than that of reference Cardaktin®. This suggests the polymer Ethocel grade 100 can be proficiently incorporated in fabrication and development of once a day controlled release matrix tablets. Copyright © 2015. Published by Elsevier B.V.

  10. Detection of low-level environmental exposure rates due to noble gas releases from the Muehleberg nuclear power plant

    International Nuclear Information System (INIS)

    Czarnecki, J.; Volkle, H.; Pretre, S.

    1980-01-01

    The increase of radiation doses in the vicinity of the Swiss Nuclear Power Stations due to airborne releases is generally expected to be below one mrem/year (about one percent of the natural radiation dose). To prove this expected rate, long term measurements with pressure ionization chambers in the vicinity of the Muhleberg plant (BWR) were conducted. Two of these chambers were installed at places where the greatest dose rates from the noble gas plumes were expected in the two prevailing wind directions. The local dose rates were continuously registered on magnetic tape to allow minicomputer evaluation. After the fuel change in the summer of 1976 the noble gas releases from Muhleberg dropped considerably. From that time the noble gas releases consisted of a very low continuous component and some rare short-time spike compoments resulting from turbine and reactor trips. The dose due to the low continuous component was determined by correlating the dose rates at the measuring points with the release measure--ments at the stack and with weather conditions, and by subtracting the natural background. The short noble gas spikes lasted from minutes to some hours and caused small dose rate increases which were easily measured with the ionization chambers, and usually amounted to doses of some microroentgens. By further correlating these dose peaks with wind direction and stack emission measurements, determination of short time atmospheric dilution factors for existing weather situations became possible. By this process, the very low annual environmental doses in the range of 1 mrem per year were determined. (author)

  11. Parents rate the ratings: a test of the validity of the American movie, television, and video game ratings.

    Science.gov (United States)

    Walsh, D A; Gentile, D A; Van Brederode, T M

    2002-02-01

    Numerous studies have documented the potential effects on young audiences of violent content in media products, including movies, television programs, and computer and video games. Similar studies have evaluated the effects associated with sexual content and messages. Cumulatively, these effects represent a significant public health risk for increased aggressive and violent behavior, spread of sexually transmitted diseases, and pediatric pregnancy. In partial response to these risks and to public and legislative pressure, the movie, television, and gaming industries have implemented ratings systems intended to provide information about the content and appropriate audiences for different films, shows, and games. We conducted a panel study to test the validity of the current movie, television, and video game rating systems. Participants used the KidScore media evaluation tool, which evaluates films, television shows, and video and computer games on 10 aspects, including the appropriateness of the media product for children on the basis of age. Results revealed that when an entertainment industry rates a product as inappropriate for children, parent raters agree that it is inappropriate for children. However, parent raters disagree with industry usage of many of the ratings designating material suitable for children of different ages. Products rated as appropriate for adolescents are of the greatest concern. The level of disagreement varies from industry to industry and even from rating to rating. Analysis indicates that the amount of violent content and portrayals of violence are the primary markers for disagreement between parent raters and industry ratings. Short-term and long-term recommendations are suggested.

  12. Motor operated valve testing and the 'rate of loading' phenomenon

    International Nuclear Information System (INIS)

    Black, B.R.

    1991-01-01

    This paper discusses valve design features which affect the ability to predict motor operated valve (MOV) performance and reviews factors which should be considered when selecting switch settings to limit stem loads. Considerable attention is given to the rate of loading phenomenon which affects the relationship between valve stem thrust and actuator spring pack deflection. Equations are developed, and testing is discussed which permit the construction of an MOV dynamic model. Factors which must be considered when maintaining switch settings correct throughout the life of the plant are discussed. And switch setting acceptance criteria for use with baseline Static and Design Basis testing are suggested

  13. Selective attenuation of norepinephrine release and stress-induced heart rate increase by partial adenosine A1 agonism.

    Directory of Open Access Journals (Sweden)

    Lorenz Bott-Flügel

    Full Text Available The release of the neurotransmitter norepinephrine (NE is modulated by presynaptic adenosine receptors. In the present study we investigated the effect of a partial activation of this feedback mechanism. We hypothesized that partial agonism would have differential effects on NE release in isolated hearts as well as on heart rate in vivo depending on the genetic background and baseline sympathetic activity. In isolated perfused hearts of Wistar and Spontaneously Hypertensive Rats (SHR, NE release was induced by electrical stimulation under control conditions (S1, and with capadenoson 6 · 10(-8 M (30 µg/l, 6 · 10(-7 M (300 µg/l or 2-chloro-N(6-cyclopentyladenosine (CCPA 10(-6 M (S2. Under control conditions (S1, NE release was significantly higher in SHR hearts compared to Wistar (766+/-87 pmol/g vs. 173+/-18 pmol/g, p<0.01. Capadenoson led to a concentration-dependent decrease of the stimulation-induced NE release in SHR (S2/S1  =  0.90 ± 0.08 with capadenoson 6 · 10(-8 M, 0.54 ± 0.02 with 6 · 10(-7 M, but not in Wistar hearts (S2/S1  =  1.05 ± 0.12 with 6 · 10(-8 M, 1.03 ± 0.09 with 6 · 10(-7 M. CCPA reduced NE release to a similar degree in hearts from both strains. In vivo capadenoson did not alter resting heart rate in Wistar rats or SHR. Restraint stress induced a significantly greater increase of heart rate in SHR than in Wistar rats. Capadenoson blunted this stress-induced tachycardia by 45% in SHR, but not in Wistar rats. Using a [(35S]GTPγS assay we demonstrated that capadenoson is a partial agonist compared to the full agonist CCPA (74+/-2% A(1-receptor stimulation. These results suggest that partial adenosine A(1-agonism dampens stress-induced tachycardia selectively in rats susceptible to strong increases in sympathetic activity, most likely due to a presynaptic attenuation of NE release.

  14. Parent Ratings of Impulsivity and Inhibition Predict State Testing Scores

    Directory of Open Access Journals (Sweden)

    Rebecca A. Lundwall

    2018-03-01

    Full Text Available One principle of cognitive development is that earlier intervention for educational difficulties tends to improve outcomes such as future educational and career success. One possible way to help students who struggle is to determine if they process information differently. Such determination might lead to clues for interventions. For example, early information processing requires attention before the information can be identified, encoded, and stored. The aim of the present study was to investigate whether parent ratings of inattention, inhibition, and impulsivity, and whether error rate on a reflexive attention task could be used to predict child scores on state standardized tests. Finding such an association could provide assistance to educators in identifying academically struggling children who might require targeted educational interventions. Children (N = 203 were invited to complete a peripheral cueing task (which measures the automatic reorienting of the brain’s attentional resources from one location to another. While the children completed the task, their parents completed a questionnaire. The questionnaire gathered information on broad indicators of child functioning, including observable behaviors of impulsivity, inattention, and inhibition, as well as state academic scores (which the parent retrieved online from their school. We used sequential regression to analyze contributions of error rate and parent-rated behaviors in predicting six academic scores. In one of the six analyses (for science, we found that the improvement was significant from the simplified model (with only family income, child age, and sex as predictors to the full model (adding error rate and three parent-rated behaviors. Two additional analyses (reading and social studies showed near significant improvement from simplified to full models. Parent-rated behaviors were significant predictors in all three of these analyses. In the reading score analysis

  15. LOFT/LP-FP-1B, Loss of Fluid Test, Fission Product Release Experiment

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The seventh OECD LOFT experiment was conducted on 19 December 1984. It was the first of the two experiments to be performed in the LOFT facility with intentional release of fission products. Its objectives were to obtain data on fission product release from the fuel-cladding gap into vapor and reflood water and to collect data on transport of these fission products through and out of the reactor coolant system. The experiment was initiated by a reactor scram with one second delayed opening of the quick-opening blowdown valves. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  16. Release of Radioactive Scrap Metal/Scrap Metal (RSM/SM) at Nevada Test Site (NTS)

    International Nuclear Information System (INIS)

    1993-01-01

    Reynolds Electrical and Engineering Company, Inc. (REECo) is the prime contractor to the US Department of Energy (DOE) in providing service and support for NTS operations. Mercury Base Camp is the main control point for the many forward areas at NTS, which covers 1,350 square miles. The forward areas are where above-ground and underground nuclear tests have been performed over the last 41 years. No metal (or other material) is returned to Mercury without first being tested for radioactivity. No radioactive metals are allowed to reenter Mercury from the forward areas, other than testing equipment. RAMATROL is the monitor check point. They check material in various ways, including swipe tests, and have a large assortment of equipment for testing. Scrap metal is also checked to address Resource Conservation and Recovery Act concerns. After addressing these issues, the scrap metals are categorized. Federal Property Management Regulations (FPMR) are followed by REECo. The nonradioactive scrap material is sold through the GSA on a scheduled basis. Radioactive scrap metal are presently held in forward areas where they were used. REECo has gained approval of their Nevada Test Site Defense Waste Acceptance Criteria, Certification, and Transfer Requirements, NVO-325 application, which will allow disposal on site, when RSM is declared a waste. The guideline that REECo uses for release limits is DOE Order 5480.11, Radiation Protection for Occupational Works, Attachment 2, Surface Radioactivity Guides, of this order, give release limits for radioactive materials. However, the removal of radioactive materials from NTS require approval by DOE Nevada Operations Office (DOE/NV) on a case-by-case basis. Requirements to consider before removal are found in DOE Order 5820.2A, Radioactive Waste Management

  17. Selected hydraulic test analysis techniques for constant-rate discharge tests

    International Nuclear Information System (INIS)

    Spane, F.A. Jr.

    1993-03-01

    The constant-rate discharge test is the principal field method used in hydrogeologic investigations for characterizing the hydraulic properties of aquifers. To implement this test, the aquifer is stressed by withdrawing ground water from a well, by using a downhole pump. Discharge during the withdrawal period is regulated and maintained at a constant rate. Water-level response within the well is monitored during the active pumping phase (i.e., drawdown) and during the subsequent recovery phase following termination of pumping. The analysis of drawdown and recovery response within the stress well (and any monitored, nearby observation wells) provides a means for estimating the hydraulic properties of the tested aquifer, as well as discerning formational and nonformational flow conditions (e.g., wellbore storage, wellbore damage, presence of boundaries, etc.). Standard analytical methods that are used for constant-rate pumping tests include both log-log type-curve matching and semi-log straight-line methods. This report presents a current ''state of the art'' review of selected transient analysis procedures for constant-rate discharge tests. Specific topics examined include: analytical methods for constant-rate discharge tests conducted within confined and unconfined aquifers; effects of various nonideal formation factors (e.g., anisotropy, hydrologic boundaries) and well construction conditions (e.g., partial penetration, wellbore storage) on constant-rate test response; and the use of pressure derivatives in diagnostic analysis for the identification of specific formation, well construction, and boundary conditions

  18. High Strain Rate Tensile Testing of Silver Nanowires: Rate-Dependent Brittle-to-Ductile Transition.

    Science.gov (United States)

    Ramachandramoorthy, Rajaprakash; Gao, Wei; Bernal, Rodrigo; Espinosa, Horacio

    2016-01-13

    The characterization of nanomaterials under high strain rates is critical to understand their suitability for dynamic applications such as nanoresonators and nanoswitches. It is also of great theoretical importance to explore nanomechanics with dynamic and rate effects. Here, we report in situ scanning electron microscope (SEM) tensile testing of bicrystalline silver nanowires at strain rates up to 2/s, which is 2 orders of magnitude higher than previously reported in the literature. The experiments are enabled by a microelectromechanical system (MEMS) with fast response time. It was identified that the nanowire plastic deformation has a small activation volume (ductile failure mode transition was observed at a threshold strain rate of 0.2/s. Transmission electron microscopy (TEM) revealed that along the nanowire, dislocation density and spatial distribution of plastic regions increase with increasing strain rate. Furthermore, molecular dynamic (MD) simulations show that deformation mechanisms such as grain boundary migration and dislocation interactions are responsible for such ductility. Finally, the MD and experimental results were interpreted using dislocation nucleation theory. The predicted yield stress values are in agreement with the experimental results for strain rates above 0.2/s when ductility is pronounced. At low strain rates, random imperfections on the nanowire surface trigger localized plasticity, leading to a brittle-like failure.

  19. Feed Preparation for Source of Alkali Melt Rate Tests

    International Nuclear Information System (INIS)

    Stone, M. E.; Lambert, D. P.

    2005-01-01

    The purpose of the Source of Alkali testing was to prepare feed for melt rate testing in order to determine the maximum melt-rate for a series of batches where the alkali was increased from 0% Na 2 O in the frit (low washed sludge) to 16% Na 2 O in the frit (highly washed sludge). This document summarizes the feed preparation for the Source of Alkali melt rate testing. The Source of Alkali melt rate results will be issued in a separate report. Five batches of Sludge Receipt and Adjustment Tank (SRAT) product and four batches of Slurry Mix Evaporator (SME) product were produced to support Source of Alkali (SOA) melt rate testing. Sludge Batch 3 (SB3) simulant and frit 418 were used as targets for the 8% Na 2 O baseline run. For the other four cases (0% Na 2 O, 4% Na 2 O, 12% Na 2 O, and 16% Na 2 O in frit), special sludge and frit preparations were necessary. The sludge preparations mimicked washing of the SB3 baseline composition, while frit adjustments consisted of increasing or decreasing Na and then re-normalizing the remaining frit components. For all batches, the target glass compositions were identical. The five SRAT products were prepared for testing in the dry fed melt-rate furnace and the four SME products were prepared for the Slurry-fed Melt-Rate Furnace (SMRF). At the same time, the impacts of washing on a baseline composition from a Chemical Process Cell (CPC) perspective could also be investigated. Five process simulations (0% Na 2 O in frit, 4% Na 2 O in frit, 8% Na 2 O in frit or baseline, 12% Na 2 O in frit, and 16% Na 2 O in frit) were completed in three identical 4-L apparatus to produce the five SRAT products. The SRAT products were later dried and combined with the complementary frits to produce identical glass compositions. All five batches were produced with identical processing steps, including off-gas measurement using online gas chromatographs. Two slurry-fed melter feed batches, a 4% Na 2 O in frit run (less washed sludge combined with

  20. A comparison of measured radionuclide release rates from Three Mile Island Unit-2 core debris for different oxygen chemical potentials

    International Nuclear Information System (INIS)

    Baston, V.F.; Hofstetter, K.J.; Ryan, R.F.

    1987-01-01

    Chemical and radiochemical analyses of reactor coolant samples taken during defueling of the Three Mile Island Unit-2 (TMI-2) reactor provide relevant data to assist in understanding the solution chemistry of the radionuclides retained within the TMI-2 reactor coolant system. Hydrogen peroxide was added to various plant systems to provide disinfection for microbial contamination and has provided the opportunity to observe radionuclide release under different oxygen chemical potentials. A comparison of the radionuclide release rates with and without hydrogen peroxide has been made for these separate but related cases, i.e., the fuel transfer canal and connecting spent-fuel pool A with the TMI-2 reactor plenum in the fuel transfer canal, core debris grab sample laboratory experiments, and the reactor vessel fluid and associated core debris. Correlation and comparison of these data indicate a physical parameter dependence (surface-to-volume ratio) affecting all radionuclide release; however, selected radionuclides also demonstrate a chemical dependence release under the different oxygen chemical potentials. Chemical and radiochemical analyses of reactor coolant samples taken during defueling of the Three Mile Island Unit-2 (TMI-2) reactor provide relevant data to assist in understanding the solution chemistry of the radionuclides retained within the TMI-2 reactor coolant system

  1. Assessment of nickel release from earrings randomly purchased in China and Thailand using the dimethylglyoxime test.

    Science.gov (United States)

    Hamann, Carsten R; Hamann, Dathan J; Hamann, Quinlan J; Hamann, Curtis P; Boonchai, Waranya; Li, Lin-Feng; Thyssen, Jacob P

    2010-04-01

    China and Thailand produce large amounts of jewellery that are sold domestically and abroad. To identify nickel release and metal content in earrings purchased in China and Thailand. A total of 557 earrings were randomly purchased from vendors in 11 markets located in Beijing, Chengdu, Bangkok, Patong Beach, and Hat Yai. Earrings were subjected to dimethylglyoxime (DMG) tests and 26 of the DMG negative earrings were further evaluated qualitatively for major and minor metal content using X-ray fluorescence spectrometry. A total of 314 Chinese earrings (31.5%) and 243 Thai earrings (29.2%) were DMG test positive. Three (11.5%) of 29 DMG negative earrings contained nickel as a major component; 7 (26.9%) of 29 DMG negative earrings contained nickel as a minor component. Excessive nickel release was frequent. This may contribute to the high prevalence of nickel allergy in both countries. Increased public education together with the adoption of a regulatory intervention in Thailand may be warranted. In China, enforcement of the 2002 Chinese National Standard GB 11887 may assist in reducing sensitization. These initiatives may eventually result in decreased morbidity among the Chinese and Thai citizens, but can potentially benefit recipient countries of these important earring producing countries.

  2. STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE

    Energy Technology Data Exchange (ETDEWEB)

    HU TA

    2009-10-26

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The hydrogen generation rate was calculated for 177 tanks using the rate equation model. Flammability calculations based on hydrogen, ammonia, and methane were performed for 177 tanks for various scenarios.

  3. 78 FR 78275 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2014

    Science.gov (United States)

    2013-12-26

    ...-11213, Notice No. 17] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2014... December 26, 2013. FOR FURTHER INFORMATION CONTACT: Jerry Powers, FRA Drug and Alcohol Program Manager, W38...-493-6313); or Sam Noe, FRA Drug and Alcohol Program Specialist, (telephone 615-719- 2951). Issued in...

  4. Pituitary Apoplexy After Thyrotropin-releasing Hormone Stimulation Test in a Patient with Pituitary Macroadenoma

    Directory of Open Access Journals (Sweden)

    Huei-Fang Wang

    2007-09-01

    Full Text Available Pituitary apoplexy is a rare complication of pituitary tumors. We report a case of a 41-year-old female with acromegaly due to a pituitary macroadenoma, who developed pituitary apoplexy after a thyrotropin-releasing hormone (TRH 200 mg intravenous injection stimulation test. Neither emergency computed tomography (CT scans nor magnetic resonance imaging (MRI, performed 6 hours and 12 hours, respectively, after the active episode, disclosed the evidence of acute hemorrhage or infarction. Two days later, the pituitary mass, removed by transsphenoidal approach, showed ischemic necrosis and acute hemorrhage. The TRH test is generally safe for evaluating pituitary function, but pituitary apoplexy may occur after the procedure. CT and MRI may miss the diagnosis of pituitary apoplexy, especially if performed immediately after the acute episode.

  5. Development and validation of a Chinese music quality rating test.

    Science.gov (United States)

    Cai, Yuexin; Zhao, Fei; Zheng, Yiqing

    2013-09-01

    The present study aims to develop and validate a Chinese music quality rating test (MQRT). In Experiment 1, 22 music pieces were initially selected and paired as a 'familiar music piece' and 'unfamiliar music piece' based on familiarities amongst the general public in the categories of classical music (6), Chinese folk music (8), and pop music (8). Following the selection criteria, one pair of music pieces from each music category was selected and used for the MQRT in Experiment 2. In Experiment 2, the MQRT was validated using these music pieces in the categories 'Pleasantness', 'Naturalness', 'Fullness', 'Roughness', and 'Sharpness'. Seventy-two adult participants and 30 normal-hearing listeners were recruited in Experiments 1 and 2, respectively. Significant differences between the familiar and unfamiliar music pieces were found in respect of pleasantness rating for folk and pop music pieces as well as in sharpness rating for pop music pieces. The comparison of music category effect on MQRT found significant differences in pleasantness, fullness, and sharpness ratings. The Chinese MQRT developed in the present study is an effective tool for assessing music quality.

  6. Maximum permissible continuous release rates of phosphorus-32 and sulphur-35 to atmosphere in a milk producing area

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, P M

    1963-01-01

    A method is given for calculating, for design purposes, the maximum permissible continuous release rates of phosphorus-32 and sulphur-35 to atmosphere with respect to milk contamination. In the absence of authoritative advice from the Medical Research Council, provisional working levels for the concentration of phosphorus-32 and sulphur-35 in milk are derived, and details are given of the agricultural assumptions involved in the calculation of the relationship between the amount of the nuclide deposited on grassland and that to be found in milk. The agricultural and meteorological conditions assumed are applicable as an annual average to England and Wales. The results (in mc/day) for phosphorus-32 and sulphur-35 for a number of stack heights and distances are shown graphically; typical values, quoted in a table, include 20 mc/day of phosphorus-32 and 30 mc/day of sulfur-35 as the maximum permissible continuous release rates with respect to ground level releases at a distance of 200 metres from pastureland.

  7. Evaluation of Plantago major L. seed mucilage as a rate controlling matrix for sustained release of propranolol hydrochloride.

    Science.gov (United States)

    Saeedi, Majid; Morteza-Semnani, Katayoun; Sagheb-Doust, Mehdi

    2013-03-01

    Polysaccharide mucilage derived from the seeds of Plantago major L. (family Plantaginaceae) was investigated for use in matrix formulations containing propranolol hydrochloride. HPMC K4M and tragacanth were used as standards for comparison. The hardness, tensile strength, and friability of tablets increased as the concentration of mucilage increased, indicating good compactibility of mucilage powders. The rate of release of propranolol hydrochloride from P. major mucilage matrices was mainly controlled by the drug/mucilage ratio. Formulations containing P. major mucilage were found to exhibit a release rate comparable to HPMC containing matrices at a lower drug/polymer ratio (drug/HPMC 2:1). These results demonstrated that P. major mucilage is a better release retardant compared to tragacanth at an equivalent content. The results of kinetic analysis showed that in F3 (containing 1:2 drug/mucilage) the highest correlation coefficient was achieved with the zero order model. The swelling and erosion studies revealed that as the proportion of mucilage in tablets was increased, there was a corresponding increase in percent swelling and a decrease in percent erosion of tablets. The DSC and FT-IR studies showed that no formation of complex between the drug and mucilage or changes in crystallinity of the drug had occurred.

  8. Forms and rates of release of Cs-137 in 2 peat soils

    International Nuclear Information System (INIS)

    Livens, F.R.; Howe, M.T.; Hemingway, J.D.; Goulding, K.W.T.; Howard, B.J.; IACR Rothamsted, Harpenden; Liverpool Univ.; Institute of Terrestrial Ecology, Grange-on-Sands

    1996-01-01

    Cation exchange resin saturated with H+ and Ca2+ was used to extract Cs-137 from peat soil at two sites in Britain affected by Cs-137 deposition following the Chernobyl accident. The technique identified three classes of Cs-137, similar to those observed for K+ in soils: ''Fast'', ''Intermediate'' and ''Slow''. These classes are probably related to the selectivity for Cs-137 of the cation exchange sites on the organic matter and the clay minerals, and to the structure of the soil. With one exception, most Cs-137 was in the ''Slow'' form and was only very slowly released to the resins, if at all. However, there was enough Cs-137 in the ''Fast'' and ''Intermediate'' forms to contaminate pasture and thus grazing animals for some years. Based on the resin technique, it is estimated that contamination will persist for several decades in uplands contaminated at these activity concentrations. (Author)

  9. Accelerated Testing Methodology in Constant Stress-Rate Testing for Advanced Structural Ceramics: A Preloading Technique

    Science.gov (United States)

    Choi, Sung R.; Gyekenyesi, John P.; Huebert, Dean; Bartlett, Allen; Choi, Han-Ho

    2001-01-01

    Preloading technique was used as a means of an accelerated testing methodology in constant stress-rate (dynamic fatigue) testing for two different brittle materials. The theory developed previously for fatigue strength as a function of preload was further verified through extensive constant stress-rate testing for glass-ceramic and CRT glass in room temperature distilled water. The preloading technique was also used in this study to identify the prevailing failure mechanisms at elevated temperatures, particularly at lower test rates in which a series of mechanisms would be associated simultaneously with material failure, resulting in significant strength increase or decrease. Two different advanced ceramics including SiC whisker-reinforced composite silicon nitride and 96 wt% alumina were used at elevated temperatures. It was found that the preloading technique can be used as an additional tool to pinpoint the dominant failure mechanism that is associated with such a phenomenon of considerable strength increase or decrease.

  10. On the rate determining step in fission gas release from high burn-up water reactor fuel during power transients

    International Nuclear Information System (INIS)

    Walker, C.T.; Mogensen, M.

    1987-01-01

    The radial distribution of grain boundary gas in a PWR and a BWR fuel is reported. The measurements were made using a new approach involving X-ray fluorescence analysis and electron probe microanalysis. In both fuels the concentration of grain boundary gas was much higher than hitherto suspected. The gas was mainly contained in the bubble/pore structure. The factors that determined the fraction of gas released from the grains and the level of gas retention on the grain boundaries are identified and discussed. The variables involved are the local fuel stoichiometry, the amount of open porosity, the magnitude of the local compressive hydrostatic stress and the interaction of metallic precipitates with gas bubbles on the grain faces. It is concluded that under transient conditions the interlinkage of gas bubbles on the grain faces and the subsequent formation of grain edge tunnels is the rate determining step for gas release; at least when high burn-up fuel is involved. (orig.)

  11. A method to evaluate fission gas release during irradiation testing of spherical fuel - HTR2008-58184

    International Nuclear Information System (INIS)

    Van Der Merwet, H.; Venter, J.

    2008-01-01

    The evaluation of fission gas release from spherical fuel during irradiation testing is critical to understand expected fuel performance under real reactor conditions. Online measurements of Krypton and Xenon fission products explain coated particle performance and contributions from graphitic matrix materials used in fuel manufacture and irradiation rig materials. Methods that are being developed to accurately evaluate fission gas release are described here together with examples of evaluations performed on irradiation tests HFR-K5, -K6 and EU1bis. (authors)

  12. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  13. Kinetic coupling of phosphate release, force generation and rate-limiting steps in the cross-bridge cycle.

    Science.gov (United States)

    Stehle, Robert; Tesi, Chiara

    2017-08-01

    A basic goal in muscle research is to understand how the cyclic ATPase activity of cross-bridges is converted into mechanical force. A direct approach to study the chemo-mechanical coupling between P i release and the force-generating step is provided by the kinetics of force response induced by a rapid change in [P i ]. Classical studies on fibres using caged-P i discovered that rapid increases in [P i ] induce fast force decays dependent on final [P i ] whose kinetics were interpreted to probe a fast force-generating step prior to P i release. However, this hypothesis was called into question by studies on skeletal and cardiac myofibrils subjected to P i jumps in both directions (increases and decreases in [P i ]) which revealed that rapid decreases in [P i ] trigger force rises with slow kinetics, similar to those of calcium-induced force development and mechanically-induced force redevelopment at the same [P i ]. A possible explanation for this discrepancy came from imaging of individual sarcomeres in cardiac myofibrils, showing that the fast force decay upon increase in [P i ] results from so-called sarcomere 'give'. The slow force rise upon decrease in [P i ] was found to better reflect overall sarcomeres cross-bridge kinetics and its [P i ] dependence, suggesting that the force generation coupled to P i release cannot be separated from the rate-limiting transition. The reasons for the different conclusions achieved in fibre and myofibril studies are re-examined as the recent findings on cardiac myofibrils have fundamental consequences for the coupling between P i release, rate-limiting steps and force generation. The implications from P i -induced force kinetics of myofibrils are discussed in combination with historical and recent models of the cross-bridge cycle.

  14. Assessment of chromium(VI) release from 848 jewellery items by use of a diphenylcarbazide spot test

    DEFF Research Database (Denmark)

    Bregnbak, David; Johansen, Jeanne D.; Hamann, Dathan

    2016-01-01

    We recently evaluated and validated a diphenylcarbazide(DPC)-based screening spot test that can detect the release of chromium(VI) ions (≥0.5 ppm) from various metallic items and leather goods (1). We then screened a selection of metal screws, leather shoes, and gloves, as well as 50 earrings......, and identified chromium(VI) release from one earring. In the present study, we used the DPC spot test to assess chromium(VI) release in a much larger sample of jewellery items (n=848), 160 (19%) of which had previously be shown to contain chromium when analysed with X-ray fluorescence spectroscopy (2)....

  15. A leukocyte activation test identifies food items which induce release of DNA by innate immune peripheral blood leucocytes.

    Science.gov (United States)

    Garcia-Martinez, Irma; Weiss, Theresa R; Yousaf, Muhammad N; Ali, Ather; Mehal, Wajahat Z

    2018-01-01

    Leukocyte activation (LA) testing identifies food items that induce a patient specific cellular response in the immune system, and has recently been shown in a randomized double blinded prospective study to reduce symptoms in patients with irritable bowel syndrome (IBS). We hypothesized that test reactivity to particular food items, and the systemic immune response initiated by these food items, is due to the release of cellular DNA from blood immune cells. We tested this by quantifying total DNA concentration in the cellular supernatant of immune cells exposed to positive and negative foods from 20 healthy volunteers. To establish if the DNA release by positive samples is a specific phenomenon, we quantified myeloperoxidase (MPO) in cellular supernatants. We further assessed if a particular immune cell population (neutrophils, eosinophils, and basophils) was activated by the positive food items by flow cytometry analysis. To identify the signaling pathways that are required for DNA release we tested if specific inhibitors of key signaling pathways could block DNA release. Foods with a positive LA test result gave a higher supernatant DNA content when compared to foods with a negative result. This was specific as MPO levels were not increased by foods with a positive LA test. Protein kinase C (PKC) inhibitors resulted in inhibition of positive food stimulated DNA release. Positive foods resulted in CD63 levels greater than negative foods in eosinophils in 76.5% of tests. LA test identifies food items that result in release of DNA and activation of peripheral blood innate immune cells in a PKC dependent manner, suggesting that this LA test identifies food items that result in release of inflammatory markers and activation of innate immune cells. This may be the basis for the improvement in symptoms in IBS patients who followed an LA test guided diet.

  16. Role of Histamine Release Test for the Evaluation of Patients with Immediate Hypersensitivity Reactions to Clavulanic Acid

    DEFF Research Database (Denmark)

    Pineda, F.; Ariza, A.; Mayorga, C.

    2015-01-01

    Immediate hypersensitivity reactions to clavulanic acid (CLV) seem to be on the increase. Diagnosis is mainly based on skin testing and the drug provocation test (DPT), procedures that are not risk free. The aim of this study was to evaluate whether the histamine release test (HRT) could help eva...

  17. Opportunities and challenges of real-time release testing in biopharmaceutical manufacturing.

    Science.gov (United States)

    Jiang, Mo; Severson, Kristen A; Love, John Christopher; Madden, Helena; Swann, Patrick; Zang, Li; Braatz, Richard D

    2017-11-01

    Real-time release testing (RTRT) is defined as "the ability to evaluate and ensure the quality of in-process and/or final drug product based on process data, which typically includes a valid combination of measured material attributes and process controls" (ICH Q8[R2]). This article discusses sensors (process analytical technology, PAT) and control strategies that enable RTRT for the spectrum of critical quality attributes (CQAs) in biopharmaceutical manufacturing. Case studies from the small-molecule and biologic pharmaceutical industry are described to demonstrate how RTRT can be facilitated by integrated manufacturing and multivariable control strategies to ensure the quality of products. RTRT can enable increased assurance of product safety, efficacy, and quality-with improved productivity including faster release and potentially decreased costs-all of which improve the value to patients. To implement a complete RTRT solution, biologic drug manufacturers need to consider the special attributes of their industry, particularly sterility and the measurement of viral and microbial contamination. Continued advances in on-line and in-line sensor technologies are key for the biopharmaceutical manufacturing industry to achieve the potential of RTRT. Related article: http://onlinelibrary.wiley.com/doi/10.1002/bit.26378/full. © 2017 Wiley Periodicals, Inc.

  18. Testing nonlinearities between Brazilian exchange rate and inflation volatilities

    Directory of Open Access Journals (Sweden)

    Christiane R. Albuquerque

    2006-12-01

    Full Text Available There are few studies, directly addressing exchange rate and inflation volatilities, and lack of consensus among them. However, this kind of study is necessary, especially under an inflation-targeting system where the monetary authority must know well price behavior. This article analyses the relation between exchange rate and inflation volatilities using a bivariate GARCH model, and therefore modeling conditional volatilities, fact largely unexplored by the literature. We find a semi-concave relation between those series, and this nonlinearity may explain their apparently disconnection under a floating exchange rate system. The article also shows that traditional tests, with non-conditional volatilities, are not robust.Existem poucos estudos, e pouco consenso, sobre a relação entre as volatilidades cambial e da inflação. Todavia, tais estudos são necessários, especialmente em um regime de metas de inflação onde a autoridade monetária deve conhecer detalhadamente o comportamento dos preços. Existem poucos estudos, e pouco consenso, sobre a relação entre as volatilidades cambial e da inflação. Todavia, tais estudos são necessários, especialmente em um regime de metas de inflação onde a autoridade monetária deve conhecer detalhadamente o comportamento dos preços. Este artigo analisa a relação entre aquelas volatilidades usando um modelo Garch bivariado, modelando, portanto, as volatilidades condicionais, enfoque pouco explorado pela literatura. Encontramos uma relação semi-côncava entre as séries, e esta não-linearidade pode explicar o aparente descolamento das mesmas em períodos de regime cambial flutuante. O artigo também mostra que os testes tradicionais, com volatilidades não-condicionais, não são robustos.

  19. Impacts of external convection on release rates in metal hydride storage tanks. Paper no. IGEC-1-080

    International Nuclear Information System (INIS)

    MacDonald, B.; Rowe, A.; Tomlinson, J.; Ho, J.

    2005-01-01

    Reversible metal hydrides can be used to store hydrogen at relatively low pressures, with very high volumetric density. The rate hydrogen can be drawn from a given tank is strongly influenced by the rate heat can be transferred to the reaction zone. Because of this, enhancing and controlling heat transfer is a key area of research in the development of metal hydride storage tanks. In this work, the impacts of external convection resistance on hydrogen release rates are examined. A one-dimensional resistive analysis determines the thermal resistances in the system based on one case where no external heat transfer enhancements are used, and a second case where external fins are used. A two-dimensional, transient model, developed in FEMLAB, is used to determine the impact of the external fins on the mass flow rate of hydrogen in more detail. For the particular metal hydride alloy (LaNi 4.8 Sn 0.2 ) and tank geometry studied, it was found that the fins have a large impact on the hydrogen flow rate during the initial stages of desorption. The flow rate with no fins is only 20% of the flow rate with fins for a full tank, 57% when the tank is 33% full, and 74% when the tank is 5% full. As the reaction proceeds, the resistance of the metal hydride alloy within the tank increases and becomes dominant. Therefore, the impact of the fins becomes less significant as the tank empties. (author)

  20. Comparing Titanium Release from Ceramic Tiles using a waste material characterization test - Influence of Calcium and Organic Matter concentrations

    DEFF Research Database (Denmark)

    Heggelund, Laura Roverskov; Hansen, Steffen Foss; Astrup, Thomas Fruergaard

    2015-01-01

    Nanomaterials are beneficial in the building industry to enhance or add certain features to commonly used materials. One example is the use of nano-titanium dioxide in the surface coating of ceramic tiles, to make the tiles surface self-cleaning. At the end of life stage, ceramic tiles might...... to assess if nano-titanium dioxide coated ceramic tiles are suitable for depositing in a landfill or not. Specifically, we used compliance batch test method, which is a simple test evaluating the release from a solid material to an aqueous media during 24 hrs. If nano-Ti particles are released from solid...... immediately after the 24 hrs. test using single particle ICPMS and Transmission Electron Microscopy imaging. The preliminary results suggest that nanoparticulate titanium is released from both tiles – with and without nano-titanium dioxide coating. The size distributions of the released particles are similar...

  1. Reaction rate estimation of controlled-release antifouling paint binders: Rosin-based systems

    DEFF Research Database (Denmark)

    Meseguer Yebra, Diego; Kiil, Søren; Dam-Johansen, Kim

    2005-01-01

    Biofouling on ship hulls is prevented by the use of antifouling (A/F) paints. Typically, sea water soluble rosin or rosin-derivatives are used as the primary means of adjusting the polishing rate of the current chemically active self-polishing paint systems to a suitable value. Previous studies h...

  2. Growth rates and post-release survival of captive neonate timber rattlesnakes Crotalus horridus

    Science.gov (United States)

    Richard N. Conner; D. Craig Rudolph; Daniel Saenz; Richard R. Schaefer; Shirley J. Burgdorf

    2003-01-01

    The need for conservation and management of rare species is becoming increasingly important as wildlife species and their habitat continue to decline. Translocation of wild captured adults to augment and reintroduce populations has been successfully used for some endangered avian species (see Carrie et al. 1999; Rudolph et al. 1992). In general, success rates for...

  3. Rates of opioid dispensing and overdose after introduction of abuse-deterrent extended-release oxycodone and withdrawal of propoxyphene.

    Science.gov (United States)

    Larochelle, Marc R; Zhang, Fang; Ross-Degnan, Dennis; Wharam, J Frank

    2015-06-01

    In the second half of 2010, abuse-deterrent extended-release oxycodone hydrochloride (OxyContin; Purdue Pharma) was introduced and propoxyphene was withdrawn from the US market. The effect of these pharmaceutical market changes on opioid dispensing and overdose rates is unknown. To evaluate the association between 2 temporally proximate changes in the opioid market and opioid dispensing and overdose rates. Claims from a large national US health insurer were analyzed, using an interrupted time series study design. Participants included an open cohort of 31.3 million commercially insured members aged 18 to 64 years between January 1, 2003, and December 31, 2012, with median follow-up of 20 months (last follow-up, December 31, 2012). Introduction of abuse-deterrent OxyContin (resistant to crushing or dissolving) on August 9, 2010, and market withdrawal of propoxyphene on November 19, 2010. Standardized opioid dispensing rates and prescription opioid and heroin overdose rates were the primary outcomes. We used segmented regression to analyze changes in outcomes from 30 quarters before to 8 quarters after the 2 interventions. Two years after the opioid market changes, total opioid dispensing decreased by 19% from the expected rate (absolute change, -32.2 mg morphine-equivalent dose per member per quarter [95% CI, -38.1 to -26.3]). By opioid subtype, the absolute change in dispensing by milligrams of morphine-equivalent dose per member per quarter at 2 years was -11.3 (95% CI, -12.4 to -10.1) for extended-release oxycodone, 3.26 (95% CI, 1.40 to 5.12) for other long-acting opioids, -8.19 (95% CI, -9.30 to -7.08) for propoxyphene, and -16.2 (95% CI, -18.8 to -13.5) for other immediate-release opioids. Two years after the market changes, the estimated overdose rate attributed to prescription opioids decreased by 20% (absolute change, -1.10 per 100,000 members per quarter [95% CI, -1.47 to -0.74]), but heroin overdose increased by 23% (absolute change, 0.26 per 100

  4. IFN-γ release assay conversions and reversions. Challenges with serial testing in U.S. health care workers.

    Science.gov (United States)

    Joshi, Manish; Monson, Thomas P; Joshi, Anita; Woods, Gail L

    2014-03-01

    IFN-γ release assays (IGRAs) including the QuantiFERON-TB gold in-tube test (QFT-GIT) are increasingly used in place of the tuberculin skin test (TST) in surveillance programs for Mycobacterium tuberculosis infection in the United States. However, data on conversions, reversions, and predictive value of QFT in such programs for health care workers (HCWs) are limited. The purpose of this study is to assess long-term reproducibility and conversion and reversion rates of QFT-GIT among HCWs who underwent serial testing at a tertiary care center in the United States. Retrospective chart review of HCWs at the Central Arkansas Veterans Healthcare System (CAVHS) who underwent serial testing with QFT-GIT as a part of their employee screening between November 1, 2008 and January 31, 2011. A total of 2,303 HCWs had at least 2 QFT-GITs 1 year apart. The initial QFT-GIT was positive for 69 and 2 were indeterminate. Of these 69 HCWs, 31 (45%) reverted on repeat testing, and 25 of 31 (80.6%) HCWs who reverted had a negative look-back TST. Of the 2,232 HCWs with an initial negative QFT-GIT, 71 (3.2%) converted on repeat testing. A third QFT-GIT assay was performed in 41 of the 71 converters and 90% (37 of 41) reverted back to negative. Only two HCWs had TST and QFT-GIT conversion. Poor IGRA reproducibility and a low predictive value of QFT-GIT conversions indicate that QFT-GIT with current interpretation criteria should not be used for serial screening of U.S. HCWs. Negative TSTs have higher reproducibility than QFT-GIT for serial testing of HCWs in low tuberculosis incidence settings.

  5. Integrated leak rate testing of the fast flux test facility reactor containment building

    International Nuclear Information System (INIS)

    James, E.B.; Farabee, O.A.; Bliss, R.J.

    1978-01-01

    The initial Integrated Leak Rate Test (ILRT) of the Fast Flux Test Facility containment building was performed from May 27 to June 2, 1978. The test was conducted in air with systems vented and with the containment recirculating coolers in operation. 10 psig and 5 psig tests were run using the absolute pressure test method. The measured leakage rates were .033% Vol/24 hr. and -.0015% Vol/24 hrs. respectively. Subsequent verification tests at both 10 psig and 5 psig proved that the test equipment was operating properly and it was sensitive enough to detect leaks at low pressures. This ILRT was performed at a lower pressure than any previous ILRT on a reactor containment structure in the United States. While the initial design requirements for ice condenser containments called for a part pressure test at 6 psig, the tests were waived due to the apparent statistical problems of data analysis and the repeatability of the data itself at such low pressure. In contrast to this belief, both the 5 and 10 psig ILRT's were performed in a successful manner at FFTF

  6. Application of insulin-like growth factor-I and insulin release test in diabetes mellitus

    International Nuclear Information System (INIS)

    Chen Dong; Ma Yongxiu; Duan Wenruo

    2003-01-01

    The purpose of this study was to determine the role of insulin-like growth factor-I (IGF-I) and insulin release test (IRT) in understanding the extent of damage to ability of reducing blood sugar in different types of diabetes mellitus (DM) and in selection of treatment plan and adjustment of using drugs. OGTT, IRT and determination of IGF-I level of 67 normal subjects and 217 DM patients were performed. The result was analyzed comparatively. The level of IGF-I was negatively correlated with the level of fasting blood sugar, and positively correlated with the level of fasting insulin. Our conclusions are: There are two ways of reducing blood sugar: one is by insulin, and the other is by IGF-I. IRT can reflect the former better, and IGF-I the latter. The combination of these two is of significant value in diagnosis and treatment of DM

  7. Nickel allergy in patch-tested female hairdressers and assessment of nickel release from hairdressers' scissors and crochet hooks

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Milting, Kristina; Bregnhøj, Anne

    2009-01-01

    the proportion of hairdressers' scissors and crochet hooks that released an excessive amount of nickel and to determine the prevalence of nickel allergy among patch-tested female hairdressers. MATERIALS: Random hairdressers' stores in Copenhagen were visited. The dimethylglyoxime (DMG) test was used to assess...... excessive nickel release. The prevalence of nickel allergy among female hairdressers from the database at Gentofte Hospital was compared with the prevalence of nickel allergy among other consecutively patch-tested dermatitis patients. RESULTS: DMG testing showed that 1 (0.5%; 95% CI = 0 - 2.0) of 200 pairs...

  8. An efficient and accurate method for computation of energy release rates in beam structures with longitudinal cracks

    DEFF Research Database (Denmark)

    Blasques, José Pedro Albergaria Amaral; Bitsche, Robert

    2015-01-01

    This paper proposes a novel, efficient, and accurate framework for fracture analysis of beam structures with longitudinal cracks. The three-dimensional local stress field is determined using a high-fidelity beam model incorporating a finite element based cross section analysis tool. The Virtual...... Crack Closure Technique is used for computation of strain energy release rates. The devised framework was employed for analysis of cracks in beams with different cross section geometries. The results show that the accuracy of the proposed method is comparable to that of conventional three......-dimensional solid finite element models while using only a fraction of the computation time....

  9. Effects of geometric non-linearity on energy release rates in a realistic wind turbine blade cross section

    DEFF Research Database (Denmark)

    Eder, Martin Alexander; Bitsche, Robert; Belloni, Federico

    2015-01-01

    Most wind turbine rotor blades comprise several adhesively connected sub-components typically made from glass fibre reinforced polymer composite materials. It is a well-known fact that wind turbine blades are prone to fail in their adhesive joints. However, owing to the complexity...... of their structural behaviour, little is known about the root causes of adhesive joint failure. This paper investigates the effects of geometrical non-linearity on energy release rates (ERRs) of transversely oriented cracks present in the adhesive joints of a wind turbine rotor blade. Utilising a computationally...

  10. Outpacing the Anthropocene: New Constraints for the Rate of Carbon Release at the Paleocene-Eocene Thermal Maximum

    Science.gov (United States)

    Wright, J. D.; Schaller, M. F.

    2012-12-01

    The Paleocene/Eocene Thermal Maximum (PETM) Carbon Isotope Excursion (CIE) is linked to benthic foraminiferal extinction and excursion taxa in planktonic foraminifera and calcareous nannofossils. Previous studies have used integrated bio-magneto-stratigraphies, cycle counting, and extraterrestrial 3He accumulation rates to produce a range of estimates for the duration of the initial onset of the PETM CIE between 750 years to 30 kyr. Durations for the total release time (onset to initiation of recovery) range from 45 to 95 kyr. Uncertainty in the timing of the onset of the PETM CIE prevents the identification of a causal mechanism, and hence understanding the biological responses. Recent work on the Paleocene/Eocene Marlboro Clay has unveiled the presence of regular couplets (~2 cm) expressed in multiple cores and exposures throughout the Atlantic Coastal Plain. Specifically, the Millville and newly recovered Wilson Lake B cores contain 750 and 660 layers through the CIE, respectively. These couplets have corresponding oxygen stable isotope cycles, arguing for a climatic origin. Orbital and millennial periodicities are far too long to explain the ~750 layers identified in the Millville core. Seasonal insolation is the only regular climate cycle that can plausibly account for the observed δ18O amplitudes (~1‰, with some cycles up to 2‰) and layer counts. Seasonal freshwater input can also augment the cyclic oscillations in δ18O, but the majority of the variability is most plausibly ascribed to temperature. Wilson Lake B and Millville have total δ13C excursions of -5 and -4.5‰ respectively, as well as highly expanded sections of the PETM CIE. In the Millville core, high-resolution, bulk stable isotope records show a 3.5‰ δ13C decrease over 12 layers across the PETM CIE onset. Concomitant with this δ13C decrease is a sharp drop in CaCO3. Decreases in both proxies require a large, sudden release of isotopically light carbon. The couplet chronology indicates

  11. Comparison of leaching tests to determine and quantify the release of inorganic contaminants in demolition waste

    International Nuclear Information System (INIS)

    Delay, Markus; Lager, Tanja; Schulz, Horst D.; Frimmel, Fritz H.

    2007-01-01

    The changes in waste management policy caused by the massive generation of waste materials (e.g. construction and demolition waste material, municipal waste incineration products) has led to an increase in the reuse and recycling of waste materials. For environmental risk assessment, test procedures are necessary to examine waste materials before they can be reused. In this article, results of column and lysimeter leaching tests having been applied to inorganic compounds in a reference demolition waste material are presented. The results show a good agreement between the leaching behaviour determined with the lysimeter unit and the column units used in the laboratory. In view of less time and system requirements compared to lysimeter systems, laboratory column units can be considered as a practicable instrument to assess the time-dependent release of inorganic compounds under conditions similar to those encountered in a natural environment. The high concentrations of elements in the seepage water at the initial stage of elution are reflected by the laboratory column leaching tests. In particular, authorities or laboratories might benefit and have an easy-to-use, but nevertheless reliable, method to serve as a basis for decision-making

  12. Sill intrusion driven fluid flow and vent formation in volcanic basins: Modeling rates of volatile release and paleoclimate effects

    Science.gov (United States)

    Iyer, Karthik; Schmid, Daniel

    2016-04-01

    Evidence of mass extinction events in conjunction with climate change occur throughout the geological record and may be accompanied by pronounced negative carbon isotope excursions. The processes that trigger such globally destructive changes are still under considerable debate. These include mechanisms such as poisoning from trace metals released during large volcanic eruptions (Vogt, 1972), CO2 released from lava degassing during the formation of Large Igneous Provinces (LIPs) (Courtillot and Renne, 2003) and CH4 release during the destabilization of sub-seafloor methane (Dickens et al., 1995), to name a few. Thermogenic methane derived from contact metamorphism associated with magma emplacement and cooling in sedimentary basins has been recently gaining considerable attention as a potential mechanism that may have triggered global climate events in the past (e.g. Svensen and Jamtveit, 2010). The discovery of hydrothermal vent complexes that are spatially associated with such basins also supports the discharge of greenhouse gases into the atmosphere (e.g. Jamtveit et al., 2004; Planke et al., 2005; Svensen et al., 2006). A previous study that investigated this process using a fluid flow model (Iyer et al., 2013) suggested that although hydrothermal plume formation resulting from sill emplacement may indeed release large quantities of methane at the surface, the rate at which this methane is released into the atmosphere is too slow to trigger, by itself, some of the negative δ13C excursions observed in the fossil record over short time scales observed in the fossil record. Here, we reinvestigate the rates of gas release during sill emplacement in a case study from the Harstad Basin off-shore Norway with a special emphasis on vent formation. The presented study is based on a seismic line that crosses multiple sill structures emplaced around 55 Ma within the Lower Cretaceous sediments. A single well-defined vent complex is interpreted above the termination of the

  13. Smoke Movement in an Atrium with a Fire with Low Rate of Heat Release

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Brohus, Henrik; Petersen, A. J.

    2008-01-01

    Results from small-scale experiments on smoke movement in an atrium are given, both with and without a vertical temperature gradient, and expressions for the smoke movement are developed on the basis of these experiments. Comparisons with a general analytical expression used for calculating...... the height to the location of the smoke layer are given. Furthermore, the paper discusses the air movement in a typical atrium exposed to different internal and external heat loads to elaborate on the use of the "flow element" expressions developed for smoke movement from a fire with a low rate of heat...

  14. Voltage stress effects on microcircuit accelerated life test failure rates

    Science.gov (United States)

    Johnson, G. M.

    1976-01-01

    The applicability of Arrhenius and Eyring reaction rate models for describing microcircuit aging characteristics as a function of junction temperature and applied voltage was evaluated. The results of a matrix of accelerated life tests with a single metal oxide semiconductor microcircuit operated at six different combinations of temperature and voltage were used to evaluate the models. A total of 450 devices from two different lots were tested at ambient temperatures between 200 C and 250 C and applied voltages between 5 Vdc and 15 Vdc. A statistical analysis of the surface related failure data resulted in bimodal failure distributions comprising two lognormal distributions; a 'freak' distribution observed early in time, and a 'main' distribution observed later in time. The Arrhenius model was shown to provide a good description of device aging as a function of temperature at a fixed voltage. The Eyring model also appeared to provide a reasonable description of main distribution device aging as a function of temperature and voltage. Circuit diagrams are shown.

  15. Optimization of detector size and scan rate for beta/gamma material release surveys

    International Nuclear Information System (INIS)

    Bishop, R.V.

    1993-01-01

    DOE facilities are required to offer for sale to the public items of salvageable value when they are no longer required by the facilities. These items have to be surveyed to ensure radioactive contamination levels do not exceed the values listed in DOE Order 5400.5. Most facilities use portable contamination monitoring.equipment with probe areas between 20 and 100 cm 2 to check for fixed contamination. This procedure is very labor intensive and results in survey costs that often exceed the costs recovered from selling the items. A solution would be to use large area (> 100 cm 2 ) detectors to find and quantify contamination. Large area scintillation detectors that can be used for beta and alpha detection simultaneously are becoming available commercially. Combining these with a rate meter that can differentiate between alpha and beta events can result in a survey that takes considerably less time to do and will save a proportional amount of money in doing so. The use and limitations of this combination of detectors and rate meters will be discussed

  16. Influence of different test parameters on in vitro drug release from topical diclofenac formulations in a vertical diffusion cell setup.

    Science.gov (United States)

    Klein, S

    2013-07-01

    In the past decades, the vertical diffusion cell has emerged as a useful device for testing drug release of topical dosage forms. However, to date neither a general USP method nor formulation-related monographs have been published in international pharmacopoeia. The purpose of the present work was to examine the influence of different test parameters in a vertical diffusion cell setup on in vitro drug release from semi-solid preparations for cutaneous application. Diclofenac was selected as the model compound. Release experiments were performed in a 7 ml Microett vertical diffusion cell system. Various test parameters, including the media composition and pH, degassing, membrane material and pore size, stirring speed and stirrer type, were varied. Results obtained with different test parameter settings clearly indicate that both drug properties and instrumental details can have a huge impact on the outcome of in vitro diffusion/drug release studies with the vertical diffusion cell. Thus, the selection of adequate test parameters is crucial for the success of the release experiments and, as shown in the present study, optimal test parameters/conditions need to be established and validated on a case by case study.

  17. On the Impact of the Fuel Dissolution Rate Upon Near-Field Releases From Nuclear Waste Disposal

    Directory of Open Access Journals (Sweden)

    A Pereira

    2016-09-01

    Full Text Available Calculations of the impact of the dissolution of spent nuclear fuel on the release from a damaged canister in a KBS-3 repository are presented. The dissolution of the fuel matrix is a complex process and the dissolution rate is known to be one of the most important parameters in performance assessment models of the near-field of a geological repository. A variability study has been made to estimate the uncertainties associated with the process of fuel dissolution. The model considered in this work is a 3D model of a KBS-3 copper canister. The nuclide used in the calculations is Cs-135. Our results confirm that the fuel degradation rate is an important parameter, however there are considerable uncertainties associated with the data and the conceptual models. Consequently, in the interests of safety one should reduce, as far as possible, the uncertainties coupled to fuel degradation.

  18. Study of the ionization rate of the released deuterium in vacuum arc discharges with metal deuteride cathodes

    Science.gov (United States)

    Liu, Fei-Xiang; Long, Ji-Dong; Zheng, Le; Dong, Pan; Li, Chen; Chen, Wei

    2018-02-01

    The ionization rate of the released deuterium from a metal deuteride cathode in vacuum arc discharges is investigated by both experiments and modeling analysis. Experimental results show that the deuterium ionization rate increases from 2% to 30% with the increasing arc current in the range of 2-100 A. Thus the full ionization assumption, as is widely used in arc plasma simulations, is not satisfied for the released deuterium at low discharge current. According to the modeling results, the neutral-to-ion conversion efficiency for the deuterium traveling across the cathodic spot region can be significantly less than one, due to the fast plasma expansion and rarefaction in the vacuum. In addition, the model also reveals that, unlike the metal atoms which are mainly ionized in the sheath region and flow back to the cathode, the deuterium ionization primarily occurs in the quasi-neutral region and moves towards the anode. Consequently, the cathodic sheath layer acts like a filter that increases the deuterium fraction beyond the sheath region.

  19. Surface displacements and energy release rates for constant stress drop slip zones in joined elastic quarter spaces

    Science.gov (United States)

    Rodgers, Michael J.; Wen, Shengmin; Keer, Leon M.

    2000-08-01

    A three-dimensional quasi-static model of faulting in an elastic half-space with a horizontal change of material properties (i.e., joined elastic quarter spaces) is considered. A boundary element method is used with a stress drop slip zone approach so that the fault surface relative displacements as well as the free surface displacements are approximated in elements over their respective domains. Stress intensity factors and free surface displacements are calculated for a variety of cases to show the phenomenological behavior of faulting in such a medium. These calculations showed that the behavior could be distinguished from a uniform half-space. Slip in a stiffer material increases, while slip in a softer material decreases the energy release rate and the free surface displacements. Also, the 1989 Kalapana earthquake was located on the basis of a series of forward searches using this method and leveling data. The located depth is 8 km, which is the closer to the seismically inferred depth than that determined from other models. Finally, the energy release rate, which can be used as a fracture criterion for fracture at this depth, is calculated to be 11.1×106 J m-2.

  20. Stationarity test with a direct test for heteroskedasticity in exchange rate forecasting models

    Science.gov (United States)

    Khin, Aye Aye; Chau, Wong Hong; Seong, Lim Chee; Bin, Raymond Ling Leh; Teng, Kevin Low Lock

    2017-05-01

    Global economic has been decreasing in the recent years, manifested by the greater exchange rates volatility on international commodity market. This study attempts to analyze some prominent exchange rate forecasting models on Malaysian commodity trading: univariate ARIMA, ARCH and GARCH models in conjunction with stationarity test on residual diagnosis direct testing of heteroskedasticity. All forecasting models utilized the monthly data from 1990 to 2015. Given a total of 312 observations, the data used to forecast both short-term and long-term exchange rate. The forecasting power statistics suggested that the forecasting performance of ARIMA (1, 1, 1) model is more efficient than the ARCH (1) and GARCH (1, 1) models. For ex-post forecast, exchange rate was increased from RM 3.50 per USD in January 2015 to RM 4.47 per USD in December 2015 based on the baseline data. For short-term ex-ante forecast, the analysis results indicate a decrease in exchange rate on 2016 June (RM 4.27 per USD) as compared with 2015 December. A more appropriate forecasting method of exchange rate is vital to aid the decision-making process and planning on the sustainable commodities' production in the world economy.

  1. Simulation of short-term fluctuations in gamma exposure rate due to radioactive cloud released from nuclear power plant

    International Nuclear Information System (INIS)

    Ichikawa, Yoichi; Shikata, Hiroshi; Ishida, Kenji; Ohba, Tachimori.

    1981-01-01

    The measured γ-exposure rate around nuclear power plants is due mainly to natural causes and radioactive clouds emitted from the plants. An exposure calculation method based on puff model has been already proposed to identify the plant contributions and to estimate values in response to short-term fluctuations of meteorological condition and the release rate. However, the calculation method by this model consumes a lot of computer time, since the calculation requires a three-dimensional integration of the distribution of the concentration from each puff. Hence, we propose a simplified method using approximate polynominal equations and interpolations. The computer time needed for the calculation with the simplified method is reduced to 1/30 of that required by the previous method. The calculation results by simplified method are compared with those by the previous method and with the measured exposure rate less natural background. The results of two different methods are in good agreement. The calculated exposure rate is within the range from half to twice as much as the measured exposure rate less background. (author)

  2. Gaia Data Release 1. Testing parallaxes with local Cepheids and RR Lyrae stars

    Science.gov (United States)

    Gaia Collaboration; Clementini, G.; Eyer, L.; Ripepi, V.; Marconi, M.; Muraveva, T.; Garofalo, A.; Sarro, L. M.; Palmer, M.; Luri, X.; Molinaro, R.; Rimoldini, L.; Szabados, L.; Musella, I.; Anderson, R. I.; Prusti, T.; de Bruijne, J. H. J.; Brown, A. G. A.; Vallenari, A.; Babusiaux, C.; Bailer-Jones, C. A. L.; Bastian, U.; Biermann, M.; Evans, D. W.; Jansen, F.; Jordi, C.; Klioner, S. A.; Lammers, U.; Lindegren, L.; Mignard, F.; Panem, C.; Pourbaix, D.; Randich, S.; Sartoretti, P.; Siddiqui, H. I.; Soubiran, C.; Valette, V.; van Leeuwen, F.; Walton, N. A.; Aerts, C.; Arenou, F.; Cropper, M.; Drimmel, R.; Høg, E.; Katz, D.; Lattanzi, M. G.; O'Mullane, W.; Grebel, E. K.; Holland, A. D.; Huc, C.; Passot, X.; Perryman, M.; Bramante, L.; Cacciari, C.; Castañeda, J.; Chaoul, L.; Cheek, N.; De Angeli, F.; Fabricius, C.; Guerra, R.; Hernández, J.; Jean-Antoine-Piccolo, A.; Masana, E.; Messineo, R.; Mowlavi, N.; Nienartowicz, K.; Ordóñez-Blanco, D.; Panuzzo, P.; Portell, J.; Richards, P. J.; Riello, M.; Seabroke, G. M.; Tanga, P.; Thévenin, F.; Torra, J.; Els, S. G.; Gracia-Abril, G.; Comoretto, G.; Garcia-Reinaldos, M.; Lock, T.; Mercier, E.; Altmann, M.; Andrae, R.; Astraatmadja, T. L.; Bellas-Velidis, I.; Benson, K.; Berthier, J.; Blomme, R.; Busso, G.; Carry, B.; Cellino, A.; Cowell, S.; Creevey, O.; Cuypers, J.; Davidson, M.; De Ridder, J.; de Torres, A.; Delchambre, L.; Dell'Oro, A.; Ducourant, C.; Frémat, Y.; García-Torres, M.; Gosset, E.; Halbwachs, J.-L.; Hambly, N. C.; Harrison, D. L.; Hauser, M.; Hestroffer, D.; Hodgkin, S. T.; Huckle, H. E.; Hutton, A.; Jasniewicz, G.; Jordan, S.; Kontizas, M.; Korn, A. J.; Lanzafame, A. C.; Manteiga, M.; Moitinho, A.; Muinonen, K.; Osinde, J.; Pancino, E.; Pauwels, T.; Petit, J.-M.; Recio-Blanco, A.; Robin, A. C.; Siopis, C.; Smith, M.; Smith, K. W.; Sozzetti, A.; Thuillot, W.; van Reeven, W.; Viala, Y.; Abbas, U.; Abreu Aramburu, A.; Accart, S.; Aguado, J. J.; Allan, P. M.; Allasia, W.; Altavilla, G.; Álvarez, M. A.; Alves, J.; Andrei, A. H.; Anglada Varela, E.; Antiche, E.; Antoja, T.; Antón, S.; Arcay, B.; Bach, N.; Baker, S. G.; Balaguer-Núñez, L.; Barache, C.; Barata, C.; Barbier, A.; Barblan, F.; Barrado y Navascués, D.; Barros, M.; Barstow, M. A.; Becciani, U.; Bellazzini, M.; Bello García, A.; Belokurov, V.; Bendjoya, P.; Berihuete, A.; Bianchi, L.; Bienaymé, O.; Billebaud, F.; Blagorodnova, N.; Blanco-Cuaresma, S.; Boch, T.; Bombrun, A.; Borrachero, R.; Bouquillon, S.; Bourda, G.; Bragaglia, A.; Breddels, M. A.; Brouillet, N.; Brüsemeister, T.; Bucciarelli, B.; Burgess, P.; Burgon, R.; Burlacu, A.; Busonero, D.; Buzzi, R.; Caffau, E.; Cambras, J.; Campbell, H.; Cancelliere, R.; Cantat-Gaudin, T.; Carlucci, T.; Carrasco, J. M.; Castellani, M.; Charlot, P.; Charnas, J.; Chiavassa, A.; Clotet, M.; Cocozza, G.; Collins, R. S.; Costigan, G.; Crifo, F.; Cross, N. J. G.; Crosta, M.; Crowley, C.; Dafonte, C.; Damerdji, Y.; Dapergolas, A.; David, P.; David, M.; De Cat, P.; de Felice, F.; de Laverny, P.; De Luise, F.; De March, R.; de Souza, R.; Debosscher, J.; del Pozo, E.; Delbo, M.; Delgado, A.; Delgado, H. E.; Di Matteo, P.; Diakite, S.; Distefano, E.; Dolding, C.; Dos Anjos, S.; Drazinos, P.; Durán, J.; Dzigan, Y.; Edvardsson, B.; Enke, H.; Evans, N. W.; Eynard Bontemps, G.; Fabre, C.; Fabrizio, M.; Falcão, A. J.; Farràs Casas, M.; Federici, L.; Fedorets, G.; Fernández-Hernández, J.; Fernique, P.; Fienga, A.; Figueras, F.; Filippi, F.; Findeisen, K.; Fonti, A.; Fouesneau, M.; Fraile, E.; Fraser, M.; Fuchs, J.; Gai, M.; Galleti, S.; Galluccio, L.; Garabato, D.; García-Sedano, F.; Garralda, N.; Gavras, P.; Gerssen, J.; Geyer, R.; Gilmore, G.; Girona, S.; Giuffrida, G.; Gomes, M.; González-Marcos, A.; González-Núñez, J.; González-Vidal, J. J.; Granvik, M.; Guerrier, A.; Guillout, P.; Guiraud, J.; Gúrpide, A.; Gutiérrez-Sánchez, R.; Guy, L. P.; Haigron, R.; Hatzidimitriou, D.; Haywood, M.; Heiter, U.; Helmi, A.; Hobbs, D.; Hofmann, W.; Holl, B.; Holland, G.; Hunt, J. A. S.; Hypki, A.; Icardi, V.; Irwin, M.; Jevardat de Fombelle, G.; Jofré, P.; Jonker, P. G.; Jorissen, A.; Julbe, F.; Karampelas, A.; Kochoska, A.; Kohley, R.; Kolenberg, K.; Kontizas, E.; Koposov, S. E.; Kordopatis, G.; Koubsky, P.; Krone-Martins, A.; Kudryashova, M.; Bachchan, R. K.; Lacoste-Seris, F.; Lanza, A. F.; Lavigne, J.-B.; Le Poncin-Lafitte, C.; Lebreton, Y.; Lebzelter, T.; Leccia, S.; Leclerc, N.; Lecoeur-Taibi, I.; Lemaitre, V.; Lenhardt, H.; Leroux, F.; Liao, S.; Licata, E.; Lindstrøm, H. E. P.; Lister, T. A.; Livanou, E.; Lobel, A.; Löffler, W.; López, M.; Lorenz, D.; MacDonald, I.; Magalhães Fernandes, T.; Managau, S.; Mann, R. G.; Mantelet, G.; Marchal, O.; Marchant, J. M.; Marinoni, S.; Marrese, P. M.; Marschalkó, G.; Marshall, D. J.; Martín-Fleitas, J. M.; Martino, M.; Mary, N.; Matijevič, G.; McMillan, P. J.; Messina, S.; Michalik, D.; Millar, N. R.; Miranda, B. M. H.; Molina, D.; Molinaro, M.; Molnár, L.; Moniez, M.; Montegriffo, P.; Mor, R.; Mora, A.; Morbidelli, R.; Morel, T.; Morgenthaler, S.; Morris, D.; Mulone, A. F.; Narbonne, J.; Nelemans, G.; Nicastro, L.; Noval, L.; Ordénovic, C.; Ordieres-Meré, J.; Osborne, P.; Pagani, C.; Pagano, I.; Pailler, F.; Palacin, H.; Palaversa, L.; Parsons, P.; Pecoraro, M.; Pedrosa, R.; Pentikäinen, H.; Pichon, B.; Piersimoni, A. M.; Pineau, F.-X.; Plachy, E.; Plum, G.; Poujoulet, E.; Prša, A.; Pulone, L.; Ragaini, S.; Rago, S.; Rambaux, N.; Ramos-Lerate, M.; Ranalli, P.; Rauw, G.; Read, A.; Regibo, S.; Reylé, C.; Ribeiro, R. A.; Riva, A.; Rixon, G.; Roelens, M.; Romero-Gómez, M.; Rowell, N.; Royer, F.; Ruiz-Dern, L.; Sadowski, G.; Sagristà Sellés, T.; Sahlmann, J.; Salgado, J.; Salguero, E.; Sarasso, M.; Savietto, H.; Schultheis, M.; Sciacca, E.; Segol, M.; Segovia, J. C.; Segransan, D.; Shih, I.-C.; Smareglia, R.; Smart, R. L.; Solano, E.; Solitro, F.; Sordo, R.; Soria Nieto, S.; Souchay, J.; Spagna, A.; Spoto, F.; Stampa, U.; Steele, I. A.; Steidelmüller, H.; Stephenson, C. A.; Stoev, H.; Suess, F. F.; Süveges, M.; Surdej, J.; Szegedi-Elek, E.; Tapiador, D.; Taris, F.; Tauran, G.; Taylor, M. B.; Teixeira, R.; Terrett, D.; Tingley, B.; Trager, S. C.; Turon, C.; Ulla, A.; Utrilla, E.; Valentini, G.; van Elteren, A.; Van Hemelryck, E.; van Leeuwen, M.; Varadi, M.; Vecchiato, A.; Veljanoski, J.; Via, T.; Vicente, D.; Vogt, S.; Voss, H.; Votruba, V.; Voutsinas, S.; Walmsley, G.; Weiler, M.; Weingrill, K.; Wevers, T.; Wyrzykowski, Ł.; Yoldas, A.; Žerjal, M.; Zucker, S.; Zurbach, C.; Zwitter, T.; Alecu, A.; Allen, M.; Allende Prieto, C.; Amorim, A.; Anglada-Escudé, G.; Arsenijevic, V.; Azaz, S.; Balm, P.; Beck, M.; Bernstein, H.-H.; Bigot, L.; Bijaoui, A.; Blasco, C.; Bonfigli, M.; Bono, G.; Boudreault, S.; Bressan, A.; Brown, S.; Brunet, P.-M.; Bunclark, P.; Buonanno, R.; Butkevich, A. G.; Carret, C.; Carrion, C.; Chemin, L.; Chéreau, F.; Corcione, L.; Darmigny, E.; de Boer, K. S.; de Teodoro, P.; de Zeeuw, P. T.; Delle Luche, C.; Domingues, C. D.; Dubath, P.; Fodor, F.; Frézouls, B.; Fries, A.; Fustes, D.; Fyfe, D.; Gallardo, E.; Gallegos, J.; Gardiol, D.; Gebran, M.; Gomboc, A.; Gómez, A.; Grux, E.; Gueguen, A.; Heyrovsky, A.; Hoar, J.; Iannicola, G.; Isasi Parache, Y.; Janotto, A.-M.; Joliet, E.; Jonckheere, A.; Keil, R.; Kim, D.-W.; Klagyivik, P.; Klar, J.; Knude, J.; Kochukhov, O.; Kolka, I.; Kos, J.; Kutka, A.; Lainey, V.; LeBouquin, D.; Liu, C.; Loreggia, D.; Makarov, V. V.; Marseille, M. G.; Martayan, C.; Martinez-Rubi, O.; Massart, B.; Meynadier, F.; Mignot, S.; Munari, U.; Nguyen, A.-T.; Nordlander, T.; O'Flaherty, K. S.; Ocvirk, P.; Olias Sanz, A.; Ortiz, P.; Osorio, J.; Oszkiewicz, D.; Ouzounis, A.; Park, P.; Pasquato, E.; Peltzer, C.; Peralta, J.; Péturaud, F.; Pieniluoma, T.; Pigozzi, E.; Poels, J.; Prat, G.; Prod'homme, T.; Raison, F.; Rebordao, J. M.; Risquez, D.; Rocca-Volmerange, B.; Rosen, S.; Ruiz-Fuertes, M. I.; Russo, F.; Serraller Vizcaino, I.; Short, A.; Siebert, A.; Silva, H.; Sinachopoulos, D.; Slezak, E.; Soffel, M.; Sosnowska, D.; Straižys, V.; ter Linden, M.; Terrell, D.; Theil, S.; Tiede, C.; Troisi, L.; Tsalmantza, P.; Tur, D.; Vaccari, M.; Vachier, F.; Valles, P.; Van Hamme, W.; Veltz, L.; Virtanen, J.; Wallut, J.-M.; Wichmann, R.; Wilkinson, M. I.; Ziaeepour, H.; Zschocke, S.

    2017-09-01

    Context. Parallaxes for 331 classical Cepheids, 31 Type II Cepheids, and 364 RR Lyrae stars in common between Gaia and the Hipparcos and Tycho-2 catalogues are published in Gaia Data Release 1 (DR1) as part of the Tycho-Gaia Astrometric Solution (TGAS). Aims: In order to test these first parallax measurements of the primary standard candles of the cosmological distance ladder, which involve astrometry collected by Gaia during the initial 14 months of science operation, we compared them with literature estimates and derived new period-luminosity (PL), period-Wesenheit (PW) relations for classical and Type II Cepheids and infrared PL, PL-metallicity (PLZ), and optical luminosity-metallicity (MV-[Fe/H]) relations for the RR Lyrae stars, with zero points based on TGAS. Methods: Classical Cepheids were carefully selected in order to discard known or suspected binary systems. The final sample comprises 102 fundamental mode pulsators with periods ranging from 1.68 to 51.66 days (of which 33 with σϖ/ϖimpressive. Conclusions: TGAS parallaxes bring a significant added value to the previous Hipparcos estimates. The relations presented in this paper represent the first Gaia-calibrated relations and form a work-in-progress milestone report in the wait for Gaia-only parallaxes of which a first solution will become available with Gaia Data Release 2 (DR2) in 2018. Full Tables A.1-A.3 are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/605/A79

  3. 49 CFR 40.323 - May program participants release drug or alcohol test information in connection with legal...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false May program participants release drug or alcohol... the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING... information pertaining to an employee's drug or alcohol test without the employee's consent in certain legal...

  4. The biowaiver extension for BCS class III drugs: the effect of dissolution rate on the bioequivalence of BCS class III immediate-release drugs predicted by computer simulation.

    Science.gov (United States)

    Tsume, Yasuhiro; Amidon, Gordon L

    2010-08-02

    The Biopharmaceutical Classification System (BCS) guidance issued by the FDA allows waivers for in vivo bioavailability and bioequivalence studies for immediate-release (IR) solid oral dosage forms only for BCS class I drugs. However, a number of drugs within BCS class III have been proposed to be eligible for biowaivers. The World Health Organization (WHO) has shortened the requisite dissolution time of BCS class III drugs on their Essential Medicine List (EML) from 30 to 15 min for extended biowaivers; however, the impact of the shorter dissolution time on AUC(0-inf) and C(max) is unknown. The objectives of this investigation were to assess the ability of gastrointestinal simulation software to predict the oral absorption of the BCS class I drugs propranolol and metoprolol and the BCS class III drugs cimetidine, atenolol, and amoxicillin, and to perform in silico bioequivalence studies to assess the feasibility of extending biowaivers to BCS class III drugs. The drug absorption from the gastrointestinal tract was predicted using physicochemical and pharmacokinetic properties of test drugs provided by GastroPlus (version 6.0). Virtual trials with a 200 mL dose volume at different drug release rates (T(85%) = 15 to 180 min) were performed to predict the oral absorption (C(max) and AUC(0-inf)) of the above drugs. Both BCS class I drugs satisfied bioequivalence with regard to the release rates up to 120 min. The results with BCS class III drugs demonstrated bioequivalence using the prolonged release rate, T(85%) = 45 or 60 min, indicating that the dissolution standard for bioequivalence is dependent on the intestinal membrane permeability and permeability profile throughout the gastrointestinal tract. The results of GastroPlus simulations indicate that the dissolution rate of BCS class III drugs could be prolonged to the point where dissolution, rather than permeability, would control the overall absorption. For BCS class III drugs with intestinal absorption patterns

  5. Factors that predict a positive response on gonadotropin-releasing hormone stimulation test for diagnosing central precocious puberty in girls

    Directory of Open Access Journals (Sweden)

    Junghwan Suh

    2013-12-01

    Full Text Available PurposeThe rapid increase in the incidence of precocious puberty in Korea has clinical and social significance. Gonadotropin-releasing hormone (GnRH stimulation test is required to diagnose central precocious puberty (CPP, however this test is expensive and time-consuming. This study aimed to identify factors that can predict a positive response to the GnRH stimulation test.MethodsClinical and laboratory parameters, including basal serum luteinizing hormone (LH, follicle-stimulating hormone (FSH, and estradiol (E2, were measured in 540 girls with clinical signs of CPP.ResultsTwo hundred twenty-nine of 540 girls with suspected CPP had a peak serum LH level higher than 5 IU/L (the CPP group. The CPP group had advanced bone age (P<0.001, accelerated yearly growth rate (P<0.001, increased basal levels of LH (P=0.02, FSH (P<0.001, E2 (P=0.001, and insulin-like growth factor-I levels (P<0.001 compared to the non-CPP group. In contrast, body weight (P<0.001 and body mass index (P<0.001 were lower in the CPP group. Although basal LH was significantly elevated in the CPP group compared to the non-CPP group, there was considerable overlap between the 2 groups. Cutoff values of basal LH (0.22 IU/L detected CPP with 87.8% sensitivity and 20.9% specificity.ConclusionNo single parameter can predict a positive response on the GnRH stimulation test with both high sensitivity and specificity. Therefore, multiple factors should be considered in evaluation of sexual precocity when deciding the timing of the GnRH stimulation test.

  6. The impact of ambient dose rate measuring network and precipitation radar system for detection of environmental radioactivity released by accident

    International Nuclear Information System (INIS)

    Bleher, M; Stoehlker, U.

    2003-01-01

    For the surveillance of environmental radioactivity, the German measuring network of BfS consists of more than 2000 stations where the ambient gamma dose rate is continuously measured. This network is a helpful tool to detect and localise enhanced environmental contamination from artificial radionuclides. The threshold for early warning is so low, that already an additional dose rate contribution of 0,07 μGy/h is detectable. However, this threshold is frequently exceeded due to precipitation events caused by washout of natural activity in air. Therefore, the precipitation radar system of the German Weather Service provides valuable information on the problem, whether the increase of the ambient dose rate is due to natural or man-made events. In case of an accidental release, the data of this radar system show small area precipitation events and potential local hot spots not detected by the measuring network. For the phase of cloud passage, the ambient dose rate measuring network provides a reliable database for the evaluation of the current situation and its further development. It is possible to compare measured data for dose rate with derived intervention levels for countermeasures like ''sheltering''. Thus, critical regions can be identified and it is possible to verify implemented countermeasures. During and after this phase of cloud passage the measured data of the monitoring network help to adapt the results of the national decision support systems PARK and RODOS. Therefore, it is necessary to derive the actual additional contribution to the ambient dose rate. Map representations of measured dose rate are rapidly available and helpful to optimise measurement strategies of mobile systems and collection strategies for samples of agricultural products. (orig.)

  7. Effect of synchronizing the rate of degradation of dietary energy and nitrogen release on growth performance in Brahman cattle

    Directory of Open Access Journals (Sweden)

    Virote Pattarajinda

    2006-01-01

    Full Text Available The objective of this research was to determine the effect of synchronizing the rate of degradation of dietary energy and nitrogen release on growth performance in Brahman beef cattle. Fifteen Brahman cattle, 1.5 years old, with an average initial body weight of 184.8±11.1 kg were assigned to one of three treatments according to a randomized complete block design. Dietary treatments contained 3 levels of synchrony index (0.39, 0.56 and 0.74 that were derived from laboratory chemical composition analysis and degradation kinetics using nylon bag technique. Diets were fed at the rate of 2.5% BW by separate concentrate and roughage. Average daily gain increased linearly (P<0.05 with increase levels of synchrony index in the diets. The digestibility of dry matter, organic matter and neutral detergent fiber increased linearly (P<0.01. The digestibility of acid detergent fiber increased linearly (P<0.05. Ruminal total volatile fatty acids concentration increased linearly (P<0.05 at 6 h post feeding. Higher concentration and fluctuation of ruminal ammonia nitrogen and blood urea nitrogen were observed in animals that received lower synchrony index in their diets. Rumen microbial population tended to increase with diets having higher levels of synchrony index. The results indicated that synchronized rate of dietary energy and nitrogen degradation improved ruminal fermentation and digestibility, thus this increased the growth rate in Brahman cattle fed with ricestraw- based diets.

  8. Effects of strain rate, test temperature and test environment on tensile properties of vandium alloys

    International Nuclear Information System (INIS)

    Gubbi, A.N.; Rowcliffe, A.F.; Eatherly, W.S.; Gibson, L.T.

    1996-01-01

    Tensile testing was carried out on SS-3 tensile specimens punched from 0.762-mm-thick sheets of the large heat of V-4Cr-4Ti and small heats of V-3Cr-3Ti and V-6Cr-6Ti. The tensile specimens were annealed at 1000 degrees for 2 h to obtain a fully recrystallized, fine grain microstructure with a grain size in the range of 10-19 μm. Room temperature tests at strain rates ranging from 10 -3 to 5 x 10 -1 /s were carried out in air; elevated temperature testing up to 700 degrees C was conducted in a vacuum better than 1 x 10 -5 torr ( -3 Pa). To study the effect of atomic hydrogen on ductility, tensile tests were conducted at room temperature in an ultra high vacuum chamber (UHV) with a hydrogen leak system

  9. Effects of strain rate, test temperature and test environment on tensile properties of vandium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Gubbi, A.N.; Rowcliffe, A.F.; Eatherly, W.S.; Gibson, L.T. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    Tensile testing was carried out on SS-3 tensile specimens punched from 0.762-mm-thick sheets of the large heat of V-4Cr-4Ti and small heats of V-3Cr-3Ti and V-6Cr-6Ti. The tensile specimens were annealed at 1000{degrees} for 2 h to obtain a fully recrystallized, fine grain microstructure with a grain size in the range of 10-19 {mu}m. Room temperature tests at strain rates ranging from 10{sup {minus}3} to 5 x 10{sup {minus}1}/s were carried out in air; elevated temperature testing up to 700{degrees}C was conducted in a vacuum better than 1 x 10{sup {minus}5} torr (<10{sup {minus}3} Pa). To study the effect of atomic hydrogen on ductility, tensile tests were conducted at room temperature in an ultra high vacuum chamber (UHV) with a hydrogen leak system.

  10. The Fukushima releases: an inverse modelling approach to assess the source term by using gamma dose rate observations

    Science.gov (United States)

    Saunier, Olivier; Mathieu, Anne; Didier, Damien; Tombette, Marilyne; Quélo, Denis; Winiarek, Victor; Bocquet, Marc

    2013-04-01

    The Chernobyl nuclear accident and more recently the Fukushima accident highlighted that the largest source of error on consequences assessment is the source term estimation including the time evolution of the release rate and its distribution between radioisotopes. Inverse modelling methods have proved to be efficient to assess the source term due to accidental situation (Gudiksen, 1989, Krysta and Bocquet, 2007, Stohl et al 2011, Winiarek et al 2012). These methods combine environmental measurements and atmospheric dispersion models. They have been recently applied to the Fukushima accident. Most existing approaches are designed to use air sampling measurements (Winiarek et al, 2012) and some of them use also deposition measurements (Stohl et al, 2012, Winiarek et al, 2013). During the Fukushima accident, such measurements are far less numerous and not as well distributed within Japan than the dose rate measurements. To efficiently document the evolution of the contamination, gamma dose rate measurements were numerous, well distributed within Japan and they offered a high temporal frequency. However, dose rate data are not as easy to use as air sampling measurements and until now they were not used in inverse modelling approach. Indeed, dose rate data results from all the gamma emitters present in the ground and in the atmosphere in the vicinity of the receptor. They do not allow one to determine the isotopic composition or to distinguish the plume contribution from wet deposition. The presented approach proposes a way to use dose rate measurement in inverse modeling approach without the need of a-priori information on emissions. The method proved to be efficient and reliable when applied on the Fukushima accident. The emissions for the 8 main isotopes Xe-133, Cs-134, Cs-136, Cs-137, Ba-137m, I-131, I-132 and Te-132 have been assessed. The Daiichi power plant events (such as ventings, explosions…) known to have caused atmospheric releases are well identified in

  11. Measurement of fission gas release, internal pressure and cladding creep rate in the fuel pins of PHWR bundle of normal discharge burnup

    Energy Technology Data Exchange (ETDEWEB)

    Viswanathan, U.K. [Post Irradiation Examination Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Sah, D.N., E-mail: dnsah@barc.gov.i [Post Irradiation Examination Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Rath, B.N.; Anantharaman, S. [Post Irradiation Examination Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)

    2009-08-01

    Fuel pins of a Pressurised Heavy Water Reactor (PHWR) fuel bundle discharged from Narora Atomic Power Station unit no. 1 after attaining a fuel burnup of 7528 MWd/tU have been subjected to two types of studies, namely (i) puncture test to estimate extent of fission gas release and internal pressure in the fuel pin and (ii) localized heating of the irradiated fuel pin to measure the creep rate of the cladding in temperature range 800 deg. C - 900 deg. C. The fission gas release in the fuel pins from the outer ring of the bundle was found to be about 8%. However, only marginal release was found in fuel pins from the middle ring and the central fuel pin. The internal gas pressure in the outer fuel pin was measured to be 0.55 +- 0.05 MPa at room temperature. In-cell isothermal heating of a small portion of the outer fuel pins was carried out at 800 deg. C, 850 deg. C and 900 deg. C for 10 min and the increase in diameter of the fuel pin was measured after heat treatment. Creep rates of the cladding obtained from the measurement of the diameter change of the cladding due to heating at 800 deg. C, 850 deg. C and 900 deg. C were found respectively to be 2.4 x 10{sup -5} s{sup -1}, 24.6 x 10{sup -5} s{sup -1} and 45.6 x 10{sup -5} s{sup -1}.

  12. Influence of the oil globule fraction on the release rate profiles from multiple W/O/W emulsions.

    Science.gov (United States)

    Bonnet, Marie; Cansell, Maud; Placin, Frédéric; Monteil, Julien; Anton, Marc; Leal-Calderon, Fernando

    2010-06-15

    Water-in-oil-in-water (W/O/W) double emulsions were prepared and the kinetics of release of magnesium ions from the internal to the external water phase was investigated as a function of the formulation and the globule volume fraction. All the emulsions were formulated using the same surface-active species (polyglycerol polyricinoleate and sodium caseinate). Also, the internal droplet and oil globule diameters were almost identical for all the systems. Two types of W/O/W emulsions were prepared based either on a synthetic oil (miglyol) or on an edible oil (olive oil). The globule volume fraction varied from 11% to 72%. At constant temperature (T=25 degrees C) and irrespective of the oil type, the percentage of magnesium released was lowered by increasing the globule fraction. In all cases, magnesium leakage occurred without film rupturing (no coalescence). Thus, the experimental data were interpreted within the frame of a model based on diffusion. The rate of release was determined by the permeation coefficient of magnesium across the oil phase and by the binding (chelation) of magnesium by caseinate molecules. The data could be adequately fitted by considering a time-dependant permeation coefficient. The better retention of magnesium at high globule fractions could account for two distinct phenomena: (i) the reduction of the relative volume of the outer phase, and (ii) the attenuation of the permeation coefficient over time induced by interfacial magnesium binding, all the more important than the globule fraction increased. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Deuterium isotope effects on toluene metabolism. Product release as a rate-limiting step in cytochrome P-450 catalysis

    International Nuclear Information System (INIS)

    Ling, K.H.; Hanzlik, R.P.

    1989-01-01

    Liver microsomes from phenobarbital-induced rats oxidize toluene to a mixture of benzyl alcohol plus o-, m- and p-cresol (ca. 69:31). Stepwise deuteration of the methyl group causes stepwise decreases in the yield of benzyl alcohol relative to cresols (ca. 24:76 for toluene-d3). For benzyl alcohol formation from toluene-d3 DV = 1.92 and D(V/K) = 3.53. Surprisingly, however, stepwise deuteration induces stepwise increases in total oxidation, giving rise to an inverse isotope effect overall (DV = 0.67 for toluene-d3). Throughout the series (i.e. d0, d1, d2, d3) the ratios of cresol isomers remain constant. These results are interpreted in terms of product release for benzyl alcohol being slower than release of cresols (or their epoxide precursors), and slow enough to be partially rate-limiting in turnover. Thus metabolic switching to cresol formation causes a net acceleration of turnover

  14. Choosing among rival poverty rates : some tests for Latin America

    OpenAIRE

    William Gruben; Darryl McLeod

    2003-01-01

    Poverty rates are now widely available, but are they reliable? Wide variations in estimated poverty rates for the same poverty line, year and country reflect an underlying reality: there is no widely accepted procedure for estimating national poverty rates. This paper proposes a simple, ex post procedure for selecting poverty rates that have certain desirable properties. Absolute poverty measures, estimated uniformly across countries, should be correlated with nonmonetary indicators that refl...

  15. Field demonstration of CO2 leakage detection in potable aquifers with a pulselike CO2-release test.

    Science.gov (United States)

    Yang, Changbing; Hovorka, Susan D; Delgado-Alonso, Jesus; Mickler, Patrick J; Treviño, Ramón H; Phillips, Straun

    2014-12-02

    This study presents two field pulselike CO2-release tests to demonstrate CO2 leakage detection in a shallow aquifer by monitoring groundwater pH, alkalinity, and dissolved inorganic carbon (DIC) using the periodic groundwater sampling method and a fiber-optic CO2 sensor for real-time in situ monitoring of dissolved CO2 in groundwater. Measurements of groundwater pH, alkalinity, DIC, and dissolved CO2 clearly deviated from their background values, showing responses to CO2 leakage. Dissolved CO2 observed in the tests was highly sensitive in comparison to groundwater pH, DIC, and alkalinity. Comparison of the pulselike CO2-release tests to other field tests suggests that pulselike CO2-release tests can provide reliable assessment of geochemical parameters indicative of CO2 leakage. Measurements by the fiber-optic CO2 sensor, showing obvious leakage signals, demonstrated the potential of real-time in situ monitoring of dissolved CO2 for leakage detection at a geologic carbon sequestration (GCS) site. Results of a two-dimensional reactive transport model reproduced the geochemical measurements and confirmed that the decrease in groundwater pH and the increases in DIC and dissolved CO2 observed in the pulselike CO2-release tests were caused by dissolution of CO2 whereas alkalinity was likely affected by carbonate dissolution.

  16. Physiochemical Characterization and Release Rate Studies of SolidDispersions of Ketoconazole with Pluronic F127 and PVP K-30

    Science.gov (United States)

    Kumar, Pankaj; Mohan, Chander; KanamSrinivasan Uma Shankar, Mara; Gulati, Monica

    2011-01-01

    In the present study solid dispersions of the antifungal drug Ketoconazole were prepared with Pluronic F-127 and PVP K-30 with an intention to improve its dissolution properties. Investigations of the properties of the dispersions were performed using release studies, Differential scanning calorimetery (DSC), X-ray powder diffraction (XRD) and Fourier transform infrared (FTIR). The results obtained showed that the rate of dissolution of Ketoconazole was considerably improved when formulated in solid dispersions with PVP K-30 and Pluronic F-127 as compared with pure drug and physical mixtures. The results from DSC and XRD studies showed the transition of crystalline nature of drug to amorphous form, while FTIR studies demonstrated the absence of drug-carriers interaction. PMID:24250403

  17. A test of Gaia Data Release 1 parallaxes: implications for the local distance scale

    Science.gov (United States)

    Casertano, Stefano; Riess, Adam G.; Bucciarelli, Beatrice; Lattanzi, Mario G.

    2017-03-01

    Aims: We present a comparison of Gaia Data Release 1 (DR1) parallaxes with photometric parallaxes for a sample of 212 Galactic Cepheids at a median distance of 2 kpc, and explore their implications on the distance scale and the local value of the Hubble constant H0. Methods: The Cepheid distances are estimated from a recent calibration of the near-infrared period-luminosity (P-L) relation. The comparison is carried out in parallax space, where the DR1 parallax errors, with a median value of half the median parallax, are expected to be well-behaved. Results: With the exception of one outlier, the DR1 parallaxes are in very good global agreement with the predictions from a well-established P-L relation, with a possible indication that the published errors may be conservatively overestimated by about 20%. This confirms that the quality of DR1 parallaxes for the Cepheids in our sample is well within their stated errors. We find that the parallaxes of 9 Cepheids brighter than G = 6 may be systematically underestimated. If interpreted as an independent calibration of the Cepheid luminosities and assumed to be otherwise free of systematic uncertainties, DR1 parallaxes are in very good agreement (within 0.3%) with the current estimate of the local Hubble constant, and in conflict at the level of 2.5σ (3.5σ if the errors are scaled) with the value inferred from Planck cosmic microwave background data used in conjunction with ΛCDM. We also test for a zeropoint error in Gaia parallaxes and find none to a precision of 20 μas. We caution however that with this early release, the complete systematic properties of the measurements may not be fully understood at the statistical level of the Cepheid sample mean, a level an order of magnitude below the individual uncertainties. The early results from DR1 demonstrate again the enormous impact that the full mission will likely have on fundamental questions in astrophysics and cosmology.

  18. A Comparative Risk Assessment of Extended Integrated Leak Rate Testing Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ji Yong; Hwang, Seok Won; Lee, Byung Sik [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2009-10-15

    This paper presents the risk impacts of extending the Integrated Leak Rate Testing (ILRT) intervals (from five years to ten years) of Yonggwang (YGN) Unit 1 and 2. These risk impacts depended on the annual variances of meteorological data and resident population. Main comparisons were performed between the initial risk assessment (2005) for the purpose of extending ILRT interval and risk reassessment (2009) where the changed plant internal configurations (core inventory and radioisotope release fraction) and plant external alterations (wind directions, rainfall and population distributions) were monitored. The reassessment showed that there was imperceptible risk increase when the ILRT interval was extended compared to the initial risk assessment. In addition, the increased value of the Large Early Release Frequency (LERF) also satisfied the acceptance guideline proposed on Reg. Guide 1.174. The MACCS II code was used for evaluating the offsite consequence analysis. The primary risk index were used as the Probabilistic Population Dose (PPD) by considering the early effects within 80 km. The Probabilistic Safety Assessment (PSA) of YGN 1 and 2 was applied to evaluate the accident frequency of each source term category and the used PSA scope was limited to internal event.

  19. Measurement of the momentum transferred between contacting bodies during the LISA test-mass release phase—uncertainty estimation

    International Nuclear Information System (INIS)

    De Cecco, M; Bortoluzzi, D; Da Lio, M; Baglivo, L; Benedetti, M

    2009-01-01

    The requirements for the Laser Interferometer Space Antenna (LISA) test-mass (TM) release phase are analysed in view of the building up of a testing facility aimed at on-Earth qualification of the release mechanism. Accordingly, the release of the TM to free-fall must provide a linear momentum transferred to the TM not exceeding 10 −5 kg m s −1 . In order to test this requirement, a double pendulum system has been developed. The mock-ups of the TM and the release-dedicated plunger are brought into contact and then the latter is quickly retracted. During and after release, the TM motion is measured by a laser interferometer. The transferred momentum is estimated from the free oscillations following the plunger retraction by means of a Wiener–Kolmogorov optimal filter. This work is aimed at modelling the measurement chain, taking into account procedure, instruments, mechanisms and data elaboration in order to estimate the uncertainty associated with the transferred momentum measurement by means of Monte Carlo simulation

  20. Proposed test method for determining discharge rates from water closets

    DEFF Research Database (Denmark)

    Nielsen, V.; Fjord Jensen, T.

    At present the rates at which discharge takes place from sanitary appliances are mostly known only in the form of estimated average values. SBI has developed a measuring method enabling determination of the exact rate of discharge from a sanitary appliance as function of time. The methods depends...

  1. Closure Report for Corrective Action Unit 536: Area 3 Release Site, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    NSTec Environmental Restoration

    2007-01-01

    Corrective Action Unit (CAU) 536 is located in Area 3 of the Nevada Test Site. CAU 536 is listed in the Federal Facility Agreement and Consent Order of 1996 as Area 3 Release Site, and comprises a single Corrective Action Site (CAS): (sm b ullet) CAS 03-44-02, Steam Jenny Discharge The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CAS 03-44-02 is clean closure. Closure activities included removing and disposing of total petroleum hydrocarbon (TPH)- and polyaromatic hydrocarbon (PAH)-impacted soil, soil impacted with plutonium (Pu)-239, and concrete pad debris. CAU 536 was closed in accordance with the NDEP-approved CAU 536 Corrective Action Plan (CAP), with minor deviations as approved by NDEP. The closure activities specified in the CAP were based on the recommendations presented in the CAU 536 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2004). This Closure Report documents CAU 536 closure activities. During closure activities, approximately 1,000 cubic yards (yd3) of hydrocarbon waste in the form of TPH- and PAH-impacted soil and debris, approximately 8 yd3 of Pu-239-impacted soil, and approximately 100 yd3 of concrete debris were generated, managed, and disposed of appropriately. Additionally, a previously uncharacterized, buried drum was excavated, removed, and disposed of as hydrocarbon waste as a best management practice. Waste minimization techniques, such as the utilization of laboratory analysis to characterize and classify waste streams, were employed during the performance of closure

  2. Xylitol vs glucose: Effect on the rate of gastric emptying and motilin, insulin, and gastric inhibitory polypeptide release

    International Nuclear Information System (INIS)

    Salminen, E.K.; Salminen, S.J.; Porkka, L.; Kwasowski, P.; Marks, V.; Koivistoinen, P.E.

    1989-01-01

    The effect of xylitol and glucose on the rate of gastric emptying and intestinal transit and on motilin, gastric inhibitory polypeptide (GIP), and insulin release were studied in human volunteers. A single oral dose of 200 mL water containing 30 g glucose or 30 g xylitol, mixed with a 99m technetium-tin (99mTc-Sn) colloid, was used. Similar dosing without the label was used in motilin, GIP, and insulin studies. Xylitol decreased the rate of gastric emptying but concomitantly accelerated intestinal transit compared with glucose. The half-times for gastric emptying were 77.5 +/- 4.6 and 39.8 +/- 3.4 min after ingestion of xylitol and glucose solutions, respectively. Glucose suppressed motilin and stimulated GIP secretion; xylitol stimulated motilin secretion but had no effect on GIP, which is currently the main candidate for the role of enterogastrone. The accelerated intestinal transit and increase in plasma motilin observed after xylitol ingestion were thought to be causally related to the diarrhea and gastrointestinal discomfort produced by it

  3. Ovarian responses and pregnancy rate with previously used intravaginal progesterone releasing devices for fixed-time artificial insemination in sheep.

    Science.gov (United States)

    Vilariño, M; Rubianes, E; Menchaca, A

    2013-01-01

    The objective was to determine serum progesterone concentrations, ovarian responses, and pregnancy rate in sheep inseminated following a short-term protocol (6 days of treatment) with a previously used controlled internal drug release-G (CIDR-G) device. In experiment 1, 30 ewes were put on a short-term protocol using a CIDR-G of first use (new devices, N = 10), second use (previously used for 6 days, N = 10), or third use (previously used twice for 6 days, N = 10). All ewes were given prostaglandin F(2α) (10 mg dinoprost) and eCG (300 IU) im at device withdrawal. Mean serum progesterone concentrations were greater for ewes treated with new versus reused devices (P synchronization and ovulation, with lower serum progesterone concentrations for reused devices. Three times used CIDR-G yielded a pregnancy rate >70%, which tended to be lower than that obtained with new devices, adding evidence of the detrimental effect of low serum progesterone concentrations on fertility in sheep. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Meacham, J.E.

    2008-01-01

    This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for al1 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 13 days for DSTs (i.e., tank 241-AZ-102) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 12 days for DSTs (i.e., tank 241-AZ-102) and 34 days for SSTs (i.e., tank 241-B-203).

  5. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Meacham, J.E.

    2009-01-01

    This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for all 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 11 days for DSTs (i.e., tank 241-AZ-10l) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 10 days for DSTs (i.e., tank 241-AZ-101) and 34 days for SSTs (i.e., tank 241-B-203).

  6. Effect of detention basin release rates on flood flows - Application of a model to the Blackberry Creek Watershed in Kane County, Illinois

    Science.gov (United States)

    Soong, David T.; Murphy, Elizabeth A.; Straub, Timothy D.

    2009-01-01

    The effects of stormwater detention basins with specified release rates are examined on the watershed scale with a Hydrological Simulation Program - FORTRAN (HSPF) continuous-simulation model. Modeling procedures for specifying release rates from detention basins with orifice and weir discharge configurations are discussed in this report. To facilitate future detention modeling as a tool for watershed management, a chart relating watershed impervious area to detention volume is presented. The report also presents a case study of the Blackberry Creek watershed in Kane County, Ill., a rapidly urbanizing area seeking to avoid future flood damages from increased urbanization, to illustrate the effects of various detention basin release rates on flood peaks and volumes and flood frequencies. The case study compares flows simulated with a 1996 land-use HSPF model to those simulated with four different 2020 projected land-use HSPF model scenarios - no detention, and detention basins with release rates of 0.08, 0.10, and 0.12 cubic feet per second per acre (ft3/s-acre), respectively. Results of the simulations for 15 locations, which included the downstream ends of all tributaries and various locations along the main stem, showed that a release rate of 0.10 ft3/s-acre, in general, can maintain postdevelopment 100-year peak-flood discharge at a similar magnitude to that of 1996 land-use conditions. Although the release rate is designed to reduce the 100-year peak flow, reduction of the 2-year peak flow is also achieved for a smaller proportion of the peak. Results also showed that the 0.10 ft3/s-acre release rate was less effective in watersheds with relatively high percentages of preexisting (1996) development than in watersheds with less preexisting development.

  7. Fission gas release behaviour of a 103 GWd/t{sub HM} fuel disc during a 1200 °C annealing test

    Energy Technology Data Exchange (ETDEWEB)

    Noirot, J., E-mail: jean.noirot@cea.fr [CEA, DEN, DEC, Cadarache, F-13108 St. Paul Lez Durance (France); Pontillon, Y. [CEA, DEN, DEC, Cadarache, F-13108 St. Paul Lez Durance (France); Yagnik, S. [EPRI, P.O. Box 10412, Palo Alto, CA 94303-0813 (United States); Turnbull, J.A. [Independent Consultant (United Kingdom); Tverberg, T. [IFE, P.O. Box 173, NO-1751 Halden (Norway)

    2014-03-15

    Within the Nuclear Fuel Industry Research (NFIR) program, several fuel variants, in the form of thin circular discs, were irradiated in the Halden Boiling Water Reactor (HBWR) to a range of burn-ups ∼100 GWd/t{sub HM}. The design of the assembly was similar to that used in other HBWR programs: the assembly contained several rods with fuel discs sandwiched between Mo discs, which limited temperature gradients within the fuel discs. One such rod contained standard grain UO{sub 2} discs (3D grain size = 18 μm) reaching a burn-up of 103 GWd/t{sub HM}. After the irradiation, the gas release upon rod puncturing was measured to be 2.9%. Detailed characterizations of one of these irradiated UO{sub 2} discs, using electron probe microanalysis (EPMA), scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS), were performed in a CEA Cadarache hot laboratory. Examination revealed the high burn-up structure (HBS) formation throughout the whole of the disc, also the fission gas distribution within this HBS, with a very high proportion of the gas in the HBS bubbles. A sibling disc was submitted to a temperature transient up to 1200 °C in the out-of-pile (OOP) annealing test device “Merarg” at a relatively low temperature ramp rate (0.2 °C/s). In addition to the total gas release during this annealing test, the release peaks throughout the temperature range were monitored. The fuel was then characterized with the same microanalysis techniques as before the annealing test to investigate the effects of this test on the microstructure of the fuel and on the fission gases. It provided valuable insights into fission gas localization and the release behaviour in UO{sub 2} fuel with high burn-up structure (HBS)

  8. Changes in cortisol release and heart rate and heart rate variability during the initial training of 3-year-old sport horses.

    Science.gov (United States)

    Schmidt, Alice; Aurich, Jörg; Möstl, Erich; Müller, Jürgen; Aurich, Christine

    2010-09-01

    Based on cortisol release, a variety of situations to which domestic horses are exposed have been classified as stressors but studies on the stress during equestrian training are limited. In the present study, Warmblood stallions (n=9) and mares (n=7) were followed through a 9 respective 12-week initial training program in order to determine potentially stressful training steps. Salivary cortisol concentrations, beat-to-beat (RR) interval and heart rate variability (HRV) were determined. The HRV variables standard deviation of the RR interval (SDRR), RMSSD (root mean square of successive RR differences) and the geometric means standard deviation 1 (SD1) and 2 (SD2) were calculated. Nearly each training unit was associated with an increase in salivary cortisol concentrations (pHRV variables SDRR, RMSSD and SD1 decreased in response to training and lowest values were reached during mounting of a rider (pHRV variables increased again. In contrast, SD2 increased with the beginning of lunging (p<0.05) and no changes in response to mounting were detectable. In conclusion, initial training is a stressor for horses. The most pronounced reaction occurred in response to mounting by a rider, a situation resembling a potentially lethal threat under natural conditions. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  9. Effect of power change on fission gas release. Re-irradiation tests of spent fuel at JMTR

    International Nuclear Information System (INIS)

    Nakamura, Jinichi; Shimizu, Michio; Ishii, Tadahiko; Endo, Yasuichi; Ohwada, Isao; Nabeya, Hideaki; Uetsuka, Hiroshi

    1999-01-01

    A full length rod irradiated at Tsuruga unit 1 was refabricated to short length rods, and rod inner pressure gauges were re-instrumented to the rods. Re-irradiation tests to study the fission gas release during power change were carried out by means of BOCA/OSF-1 facility at the JMTR. In the tests, steady state operation at 40 kW/m and power cycling operations between 20 and 40 kW/m were conducted for the same high power holding time, and the rod inner pressure change during the tests was measured. The rod inner pressure increase was observed during power change, especially during power reduction. The rod inner pressure increase during a power cycling depended on the length of the high power operation just before the power cycling. The fission gas release during power reduction is estimated to be the release from fission gas bubbles on the grain boundary caused by the thermal stress in the pellet during power reduction. When steady state operation and power cycling were repeated at the power levels of 30, 35 and 40 kW/m, the power cycling accelerated the fission gas release compared with the steady state operation. (author)

  10. Statistical atmospheric inversion of local gas emissions by coupling the tracer release technique and local-scale transport modelling: a test case with controlled methane emissions

    Directory of Open Access Journals (Sweden)

    S. Ars

    2017-12-01

    Full Text Available This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping

  11. Statistical atmospheric inversion of local gas emissions by coupling the tracer release technique and local-scale transport modelling: a test case with controlled methane emissions

    Science.gov (United States)

    Ars, Sébastien; Broquet, Grégoire; Yver Kwok, Camille; Roustan, Yelva; Wu, Lin; Arzoumanian, Emmanuel; Bousquet, Philippe

    2017-12-01

    This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping with the distances

  12. Closure Report for Corrective Action Unit 300: Surface Release Areas Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    NSTec Environmental Restoration

    2007-01-01

    Corrective Action Unit (CAU) 300 is located in Areas 23, 25, and 26 of the Nevada Test Site, which is located approximately 65 miles northwest of Las Vegas, Nevada. CAU 300 is listed in the Federal Facility Agreement and Consent Order of 1996 as Surface Release Areas and is comprised of the following seven Corrective Action Sites (CASs), which are associated with the identified Building (Bldg): (sm b ullet) CAS 23-21-03, Bldg 750 Surface Discharge (sm b ullet) CAS 23-25-02, Bldg 750 Outfall (sm b ullet) CAS 23-25-03, Bldg 751 Outfall (sm b ullet) CAS 25-60-01, Bldg 3113A Outfall (sm b ullet) CAS 25-60-02, Bldg 3901 Outfall (sm b ullet) CAS 25-62-01, Bldg 3124 Contaminated Soil (sm b ullet) CAS 26-60-01, Bldg 2105 Outfall and Decon Pad The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CASs 23-21-03, 23-25-02, and 23-25-03 is no further action. As a best management practice, approximately 48 feet of metal piping was removed from CAS 23-25-02 and disposed of as sanitary waste. The NDEP-approved corrective action alternative for CASs 25-60-01, 25-60-02, 25-62-01, and 26-60-01, is clean closure. Closure activities for these CASs included removing and disposing of soil impacted with total petroleum hydrocarbons-diesel range organics (TPH-DRO), polychlorinated biphenyls (PCBs), semivolatile organic compounds (SVOCs), and cesium (Cs)-137, concrete impacted with TPH-DRO, and associated piping impacted with TPH-DRO. CAU 300 was closed in accordance with the NDEP-approved CAU 300 Corrective Action Plan (CAP) (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2006). The closure activities specified in the CAP were based on the recommendations presented in the CAU 300 Corrective Action Decision Document (NNSA/NSO, 2005). This Closure Report documents CAU 300 closure activities. During closure activities, approximately 40 cubic yards (yd3) of low-level waste consisting of TPH

  13. Closure Report for Corrective Action Unit 300: Surface Release Areas Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Restoration

    2007-07-01

    Corrective Action Unit (CAU) 300 is located in Areas 23, 25, and 26 of the Nevada Test Site, which is located approximately 65 miles northwest of Las Vegas, Nevada. CAU 300 is listed in the Federal Facility Agreement and Consent Order of 1996 as Surface Release Areas and is comprised of the following seven Corrective Action Sites (CASs), which are associated with the identified Building (Bldg): {sm_bullet} CAS 23-21-03, Bldg 750 Surface Discharge {sm_bullet} CAS 23-25-02, Bldg 750 Outfall {sm_bullet} CAS 23-25-03, Bldg 751 Outfall {sm_bullet} CAS 25-60-01, Bldg 3113A Outfall {sm_bullet} CAS 25-60-02, Bldg 3901 Outfall {sm_bullet} CAS 25-62-01, Bldg 3124 Contaminated Soil {sm_bullet} CAS 26-60-01, Bldg 2105 Outfall and Decon Pad The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CASs 23-21-03, 23-25-02, and 23-25-03 is no further action. As a best management practice, approximately 48 feet of metal piping was removed from CAS 23-25-02 and disposed of as sanitary waste. The NDEP-approved corrective action alternative for CASs 25-60-01, 25-60-02, 25-62-01, and 26-60-01, is clean closure. Closure activities for these CASs included removing and disposing of soil impacted with total petroleum hydrocarbons-diesel range organics (TPH-DRO), polychlorinated biphenyls (PCBs), semivolatile organic compounds (SVOCs), and cesium (Cs)-137, concrete impacted with TPH-DRO, and associated piping impacted with TPH-DRO. CAU 300 was closed in accordance with the NDEP-approved CAU 300 Corrective Action Plan (CAP) (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2006). The closure activities specified in the CAP were based on the recommendations presented in the CAU 300 Corrective Action Decision Document (NNSA/NSO, 2005). This Closure Report documents CAU 300 closure activities. During closure activities, approximately 40 cubic yards (yd3) of low-level waste consisting of TPH-DRO-, PCB

  14. Demonstration of load rating capabilities through physical load testing : Sioux County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  15. Demonstration of load rating capabilities through physical load testing : Johnson County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  16. Demonstration of load rating capabilities through physical load testing : Ida County bridge case study.

    Science.gov (United States)

    2013-08-01

    The objective of this work, Pilot Project - Demonstration of Capabilities and Benefits of Bridge Load Rating through Physical Testing, was to demonstrate the capabilities for load testing and rating bridges in Iowa, study the economic benefit of perf...

  17. Chromium(III) release from chromium‐tanned leather elicits allergic contact dermatitis: a use test study

    Science.gov (United States)

    Erfani, Behnaz; Matura, Mihály; Lidén, Carola

    2018-01-01

    Summary Background Chromium (Cr) is a common skin sensitizer. The use of Cr(VI) in leather is restricted in the EU, but that of Cr(III) is not. Objectives To assess whether prolonged exposure to Cr‐tanned leather with mainly Cr(III) release may elicit allergic contact dermatitis in Cr‐allergic individuals. Method Ten Cr‐allergic subjects and 22 controls were patch tested with serial dilutions of Cr(III) and Cr(VI), and with leather samples. They then conducted a use test with a Cr‐tanned and a Cr‐free leather bracelet over a period of 3 weeks, for 12 h per day. Cr deposited on the skin from the bracelets was measured in the controls, and the diphenylcarbazide test for Cr(VI) and extraction tests for Cr(III) and Cr(VI) were conducted for the different leathers. Results Four of 10 Cr‐allergic subjects developed positive reactions to the Cr‐tanned bracelet within 7–21 days, whereas only 1 of 10 had a positive patch test reaction to this leather. Cr released from the Cr‐tanned leather was most probably entirely Cr(III), with a quantifiable amount being deposited on the skin. Conclusions This study strongly suggests that prolonged and repeated exposure to Cr‐tanned leather with mainly Cr(III) release is capable of eliciting allergic contact dermatitis in Cr‐allergic individuals. PMID:29322530

  18. Diagnostic value of scratch-chamber test, skin prick test, histamine release and specific IgE in birch-allergic patients with oral allergy syndrome to apple

    DEFF Research Database (Denmark)

    Osterballe, M; Scheller, R; Stahl Skov, P

    2003-01-01

    BACKGROUND: The aim of the study was to examine the diagnostic value of skin prick test (SPT), scratch-chamber test (SCT), histamine release (HR) and specific immunoglobulin E (IgE) in birch-allergic patients with oral allergy syndrome to apple. METHODS: Ten birch-allergic patients with oral...... a detailed case history about symptoms of oral allergy syndrome combined with a SPT with fresh apple peel or A72 will be useful....

  19. Theoretical prediction of energy release rate for interface crack initiation by thermal stress in environmental barrier coatings for ceramics

    International Nuclear Information System (INIS)

    Kawai, E; Umeno, Y

    2017-01-01

    As weight reduction of turbines for aircraft engines is demanded to improve fuel consumption and curb emission of carbon dioxide, silicon carbide (SiC) fiber reinforced SiC matrix composites (SiC/SiC) are drawing enormous attention as high-pressure turbine materials. For preventing degradation of SiC/SiC, environmental barrier coatings (EBC) for ceramics are deposited on the composites. The purpose of this study is to establish theoretical guidelines for structural design which ensures the mechanical reliability of EBC. We conducted finite element method (FEM) analysis to calculate energy release rates (ERRs) for interface crack initiation due to thermal stress in EBC consisting of Si-based bond coat, Mullite and Ytterbium (Yb)-silicate layers on a SiC/SiC substrate. In the FEM analysis, the thickness of one EBC layer was changed from 25 μm to 200 μm while the thicknesses of the other layers were fixed at 25 μm, 50 μm and 100 μm. We compared ERRs obtained by the FEM analysis and a simple theory for interface crack in a single-layered structure where ERR is estimated as nominal strain energy in the coating layers multiplied by a constant factor (independent of layer thicknesses). We found that, unlike the case of single-layered structures, the multiplication factor is no longer a constant but is determined by the combination of consisting coating layer thicknesses. (paper)

  20. Theoretical prediction of energy release rate for interface crack initiation by thermal stress in environmental barrier coatings for ceramics

    Science.gov (United States)

    Kawai, E.; Umeno, Y.

    2017-05-01

    As weight reduction of turbines for aircraft engines is demanded to improve fuel consumption and curb emission of carbon dioxide, silicon carbide (SiC) fiber reinforced SiC matrix composites (SiC/SiC) are drawing enormous attention as high-pressure turbine materials. For preventing degradation of SiC/SiC, environmental barrier coatings (EBC) for ceramics are deposited on the composites. The purpose of this study is to establish theoretical guidelines for structural design which ensures the mechanical reliability of EBC. We conducted finite element method (FEM) analysis to calculate energy release rates (ERRs) for interface crack initiation due to thermal stress in EBC consisting of Si-based bond coat, Mullite and Ytterbium (Yb)-silicate layers on a SiC/SiC substrate. In the FEM analysis, the thickness of one EBC layer was changed from 25 μm to 200 μm while the thicknesses of the other layers were fixed at 25 μm, 50 μm and 100 μm. We compared ERRs obtained by the FEM analysis and a simple theory for interface crack in a single-layered structure where ERR is estimated as nominal strain energy in the coating layers multiplied by a constant factor (independent of layer thicknesses). We found that, unlike the case of single-layered structures, the multiplication factor is no longer a constant but is determined by the combination of consisting coating layer thicknesses.

  1. Energy release rate analysis on the interface cracks of enamel-cement-bracket fracture using virtual crack closure technique

    Science.gov (United States)

    Samshuri, S. F.; Daud, R.; Rojan, M. A.; Mat, F.; Basaruddin, K. S.; Hassan, R.

    2017-10-01

    This paper presents the energy method to evaluate fracture behavior of enamel-cement-bracket system based on cement thickness. Finite element (FE) model of enamel-cement-bracket was constructed by using ANSYS Parametric Design Language (APDL). Three different thickness were used in this study, 0.05, 0.2, and 0.271 mm which assigned as thin, medium and thick for both enamel-cement and cement bracket interface cracks. Virtual crack closure technique (VCCT) was implemented as a simulation method to calculated energy release rate (ERR). Simulation results were obtained for each thickness are discussed by using Griffith’s energy balance approach. ERR for thin thickness are found to be the lowest compared to medium and thick. Peak value of ERR also showed a significant different between medium and thick thickness. Therefore, weakest bonding occurred at low cement thickness because less load required to produce enough energy to detach the bracket. For medium and thick thickness, both increased rapidly in energy value at about the mid-point of the enamel-cement interface. This behavior occurred because of the increasing in mechanical and surface energy when the cracks are increasing. However, result for thick thickness are higher at mid-point compared to thin thickness. In conclusion, fracture behavior of enamel cracking process for medium most likely the safest to avoid enamel fracture and withstand bracket debonding.

  2. Observational Test of the Dayside Magnetopause Reconnection Rate

    Science.gov (United States)

    Wang, S.; Kistler, L. M.; Mouikis, C.

    2014-12-01

    In asymmetric reconnection, the reconnection rate (R) is expected to follow the Cassak-Shay formula with an aspect ratio of around 0.1. At the magnetopause, reconnection is asymmetric, with the dense shocked solar wind population on the magnetosheath side, and a normally hot and tenuous population on the magnetospheric side. However, the hot magnetospheric population can contain a significant O+ component that increases the mass density, and the magnetospheric population may also include a cold dense population of plasmaspheric origin. We perform a statistical study of 13 magnetopause reconnection events observed by Cluster to determine how the reconnection rate depends on these different populations. The events are mainly at high latitudes, due to the Cluster orbit. Our results show that the measured R generally follows the Cassak-Shay prediction when all populations are included. However, the predicted rate only considering the magnetosheath contribution also correlates well with the measured R. For individual events, cold ions can make a comparable contribution to the magnetosheath H+ when there are plasmaspheric drainage plumes; the contribution of the magnetospheric hot O+ can be up to ~30%. However, the variation of solar wind conditions has a larger effect on the variation in the reconnection rate. The aspect ratio does not vary systematically with the O+ content, and 0.1 is a reasonable estimation. The outflow velocity is around the hybrid Alfven speed, but there is not a strong correlation. This may be due to motion of the x-line, or effects of the magnetosheath shear flow.

  3. Multiple Maximum Exposure Rates in Computerized Adaptive Testing

    Science.gov (United States)

    Ramon Barrada, Juan; Veldkamp, Bernard P.; Olea, Julio

    2009-01-01

    Computerized adaptive testing is subject to security problems, as the item bank content remains operative over long periods and administration time is flexible for examinees. Spreading the content of a part of the item bank could lead to an overestimation of the examinees' trait level. The most common way of reducing this risk is to impose a…

  4. A spot test for detection of cobalt release – early experience and findings

    DEFF Research Database (Denmark)

    Thyssen, Jacob P.; Menné, Torkil; Johansen, Jeanne D.

    2010-01-01

    Background: It is often difficult to establish clinical relevance of metal exposure in cobalt-allergic patients. Dermatologists and patients may incorrectly assume that many metallic items release cobalt at levels that may cause cobalt dermatitis. Cobalt-allergic patients may be unaware that they...

  5. A spot test for detection of cobalt release - early experience and findings

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Menné, Torkil; Johansen, Jeanne D

    2010-01-01

    It is often difficult to establish clinical relevance of metal exposure in cobalt-allergic patients. Dermatologists and patients may incorrectly assume that many metallic items release cobalt at levels that may cause cobalt dermatitis. Cobalt-allergic patients may be unaware that they are exposed...

  6. Joint release rate estimation and measurement-by-measurement model correction for atmospheric radionuclide emission in nuclear accidents: An application to wind tunnel experiments.

    Science.gov (United States)

    Li, Xinpeng; Li, Hong; Liu, Yun; Xiong, Wei; Fang, Sheng

    2018-03-05

    The release rate of atmospheric radionuclide emissions is a critical factor in the emergency response to nuclear accidents. However, there are unavoidable biases in radionuclide transport models, leading to inaccurate estimates. In this study, a method that simultaneously corrects these biases and estimates the release rate is developed. Our approach provides a more complete measurement-by-measurement correction of the biases with a coefficient matrix that considers both deterministic and stochastic deviations. This matrix and the release rate are jointly solved by the alternating minimization algorithm. The proposed method is generic because it does not rely on specific features of transport models or scenarios. It is validated against wind tunnel experiments that simulate accidental releases in a heterogonous and densely built nuclear power plant site. The sensitivities to the position, number, and quality of measurements and extendibility of the method are also investigated. The results demonstrate that this method effectively corrects the model biases, and therefore outperforms Tikhonov's method in both release rate estimation and model prediction. The proposed approach is robust to uncertainties and extendible with various center estimators, thus providing a flexible framework for robust source inversion in real accidents, even if large uncertainties exist in multiple factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Tests of a high rate pixel detector for CMS upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Mersi, Stefano [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States). et al.

    2013-07-13

    This is a Technical Scope of Work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of the CMS Pixel group, which consists of individuals from the Bristol University, CERN, Fermilab, Rutherford Laboratory (UK), and National Taiwan University who have committed to participate in beam tests to be carried out during the 2013 - 2014 Fermilab Test Beam Facility program. The TSW is intended solely for the purpose of recording expectations for budget estimates and work allocations for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to modify this TSW to reflect such required adjustments. Actual contractual obligations will be set forth in separate documents. This TSW fulfills Article 1 (facilities and scope of work) of the User Agreements signed (or still

  8. Nitric-glycolic flowsheet testing for maximum hydrogen generation rate

    Energy Technology Data Exchange (ETDEWEB)

    Martino, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Williams, M. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-01

    The Defense Waste Processing Facility (DWPF) at the Savannah River Site is developing for implementation a flowsheet with a new reductant to replace formic acid. Glycolic acid has been tested over the past several years and found to effectively replace the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the chemical generation of hydrogen and ammonia, allows purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allows for effective adjustment of the SRAT/SME rheology, and is favorable with respect to melter flammability. The objective of this work was to perform DWPF Chemical Process Cell (CPC) testing at conditions that would bound the catalytic hydrogen production for the nitric-glycolic flowsheet.

  9. Acceptance Rate of HIV Testing among Women Seeking Induced ...

    African Journals Online (AJOL)

    A l\\'aide d\\'un questionnaire semi-structuré et auto-administré, nous avons interviewé 1051 femmes qui recherchaient l\\'avortement provoqué dans quatre cliniques selectionnées au hazard à Benin City entre janvier et septembre 2002. Les échantillons sanguins de celles qui ont accepté le test du VIH ont été collectés et ont ...

  10. Radiological effluents released from nuclear rocket and ramjet engine tests at the Nevada Test Site 1959 through 1969: Fact Book

    Energy Technology Data Exchange (ETDEWEB)

    Friesen, H.N.

    1995-06-01

    Nuclear rocket and ramjet engine tests were conducted on the Nevada Test Site (NTS) in Area 25 and Area 26, about 80 miles northwest of Las Vegas, Nevada, from July 1959 through September 1969. This document presents a brief history of the nuclear rocket engine tests, information on the off-site radiological monitoring, and descriptions of the tests.

  11. Determination of fission gas release of spent nuclear fuel in puncturing test and in leaching experiments under anoxic conditions

    Energy Technology Data Exchange (ETDEWEB)

    González-Robles, E., E-mail: ernesto.gonzalez-robles@kit.edu [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Metz, V. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Wegen, D.H. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Herm, M. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Papaioannou, D. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Bohnert, E. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Gretter, R. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Müller, N. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany); Nasyrow, R.; Weerd, W. de; Wiss, T. [European Commission, Joint Research Centre, Institute for Transuranium Elements (JRC-ITU), P.O. Box 2340, 76125, Karlsruhe (Germany); Kienzler, B. [Karlsruhe Institute of Technology, Institute for Nuclear Waste Disposal (KIT-INE), P.O. Box 3640, D-76021, Karlsruhe (Germany)

    2016-10-15

    During reactor operation the fission gases Kr and Xe are formed within the UO{sub 2} matrix of nuclear fuel. Their quantification is important to evaluate their impact on critical parameters regarding the fuel behaviour during irradiation and (long-term) interim storage, such as internal pressure of the fuel rod and fuel swelling. Moreover the content of Kr and Xe in the plenum of a fuel rod and their content in the UO{sub 2} fuel itself are widely used as indicators for the release properties of {sup 129}I, {sup 137}Cs, and other safety relevant radionuclides with respect to final disposal of spent nuclear fuel. The present study deals with the fission gas release from spent nuclear fuel exposed to simulated groundwater in comparison with the fission gas previously released to the fuel rod plenum during irradiation in reactor. In a unique approach we determined both the Kr and Xe inventories in the plenum by means of a puncturing test and in leaching experiments with a cladded fuel pellet and fuel fragments in bicarbonate water under 3.2 bar H{sub 2} overpressure. The fractional inventory of the fission gases released during irradiation into the plenum was (8.3 ± 0.9) %. The fraction of inventory of fission gases released during the leaching experiments was (17 ± 2) % after 333 days of leaching of the cladded pellet and (25 ± 2) % after 447 days of leaching of the fuel fragments, respectively. The relatively high release of fission gases in the experiment with fuel fragments was caused by the increased accessibility of water to the Kr and Xe occluded in the fuel.

  12. Baseline monitoring and simulated liquid release test report for Tank W-9, Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1997-08-01

    This document provides the Environmental Restoration Program with the baseline dry well conductivity monitoring data and simulated liquid release tests to support the use of Gunite and Associated Tank (GAAT) W-9 as a temporary consolidation tank during waste removal operations. Information provided in this report forms part of the technical basis for criticality safety, systems safety, engineering design and waste management as they apply to the GAAT treatability study and waste removal actions

  13. Predictability of Exchange Rates in Sri Lanka: A Test of the Efficient Market Hypothesis

    OpenAIRE

    Guneratne B Wickremasinghe

    2007-01-01

    This study examined the validity of the weak and semi-strong forms of the efficient market hypothesis (EMH) for the foreign exchange market of Sri Lanka. Monthly exchange rates for four currencies during the floating exchange rate regime were used in the empirical tests. Using a battery of tests, empirical results indicate that the current values of the four exchange rates can be predicted from their past values. Further, the tests of semi-strong form efficiency indicate that exchange rate pa...

  14. Formulation of a modified release metformin. HCl matrix tablet: influence of some hydrophilic polymers on release rate and in-vitro evaluation

    Directory of Open Access Journals (Sweden)

    John Rojas

    2011-09-01

    Full Text Available Metformin hydrochloride is an antidiabetic agent which improves glucose tolerance in patients with type 2 diabetes and reduces basal plasma levels of glucose. In this study, a simplex centroid experimental design with 69 runs was used to select the best combination of some hydrophilic polymers that rendered a 24 h in-vitro release profile of metformin.HCl. The Korsmeyer-Peppas model was used to model the dissolution profiles since it presented the best fit to the experimental data. Further, a cubic model predicted the best formulation of metformin.HCl containing polyvinyl pyrrolidone, ethyl cellulose, hydroxypropyl methyl cellulose, carrageenan, sodium alginate, and gum arabic at 6.26, 68.7, 6.26, 6.26, 6.26 and 6.26 % levels, respectively. The validation runs confirmed the accuracy of the cubic model with six components for predicting the best set of components which rendered a once-a-day modified release hydrophilic matrix tablet in compliance with the USP specifications.O cloridrato de metformina é um agente antidiabético que melhora a tolerância à glicose em pacientes com diabetes tipo 2 e reduz os níveis plasmáticos basais de glicose. Neste estudo, um projeto experimental do tipo "centróide simplex" com 69 tomadas foi usado para selecionar a melhor combinação de alguns polímeros hidrofílicos que gerou um perfil de liberação da metformina.HCl de 24 horas. O modelo Korsmeyer-Peppas foi usado para modelar os perfis de dissolução, uma vez que apresentou os melhores ajustes aos dados experimentais. Além disso, um modelo cúbico previu a melhor formulação de metformina.HCl sendo aquela contendo polivinilpirrolidona, etilcelulose, hidroxipropilmetil celulose, carragena, alginato de sódio e goma arábica nos níveis 6.26, 68.7, 6.26, 6.26, 6.26 e 6.26 %, respectivamente. As corridas de validação confirmaram a precisão do modelo cúbico com os seis componentes para prever o melhor conjunto de componentes que originou uma

  15. Evaluation of strain-rate sensitivity of ion-irradiated austenitic steel using strain-rate jump nanoindentation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kasada, Ryuta, E-mail: r-kasada@iae.kyoto-u.ac.jp [Institute of Advanced Energy, Kyoto University Gokasho, Uji 611-0011, Kyoto (Japan); Konishi, Satoshi [Institute of Advanced Energy, Kyoto University Gokasho, Uji 611-0011, Kyoto (Japan); Hamaguchi, Dai; Ando, Masami; Tanigawa, Hiroyasu [Japan Atomic Energy Agency, Rokkasho, Aomori (Japan)

    2016-11-01

    Highlights: • We examined strain-rate jump nanoindentation on ion-irradiated stainless steel. • We observed irradiation hardening of the ion-irradiated stainless steel. • We found that strain-rate sensitivity parameter was slightly decreased after the ion-irradiation. - Abstract: The present study investigated strain-rate sensitivity (SRS) of a single crystal Fe–15Cr–20Ni austenitic steel before and after 10.5 MeV Fe{sup 3+} ion-irradiation up to 10 dpa at 300 °C using a strain-rate jump (SRJ) nanoindentation test. It was found that the SRJ nanoindentation test is suitable for evaluating the SRS at strain-rates from 0.001 to 0.2 s{sup −1}. Indentation size effect was observed for depth dependence of nanoindentation hardness but not the SRS. The ion-irradiation increased the hardness at the shallow depth region but decreased the SRS slightly.

  16. Structural and functional analysis of a FeoB A143S G5 loop mutant explains the accelerated GDP release rate.

    Science.gov (United States)

    Guilfoyle, Amy P; Deshpande, Chandrika N; Vincent, Kimberley; Pedroso, Marcelo M; Schenk, Gerhard; Maher, Megan J; Jormakka, Mika

    2014-05-01

    GTPases (G proteins) hydrolyze the conversion of GTP to GDP and free phosphate, comprising an integral part of prokaryotic and eukaryotic signaling, protein biosynthesis and cell division, as well as membrane transport processes. The G protein cycle is brought to a halt after GTP hydrolysis, and requires the release of GDP before a new cycle can be initiated. For eukaryotic heterotrimeric Gαβγ proteins, the interaction with a membrane-bound G protein-coupled receptor catalyzes the release of GDP from the Gα subunit. Structural and functional studies have implicated one of the nucleotide binding sequence motifs, the G5 motif, as playing an integral part in this release mechanism. Indeed, a Gαs G5 mutant (A366S) was shown to have an accelerated GDP release rate, mimicking a G protein-coupled receptor catalyzed release state. In the present study, we investigate the role of the equivalent residue in the G5 motif (residue A143) in the prokaryotic membrane protein FeoB from Streptococcus thermophilus, which includes an N-terminal soluble G protein domain. The structure of this domain has previously been determined in the apo and GDP-bound states and in the presence of a transition state analogue, revealing conformational changes in the G5 motif. The A143 residue was mutated to a serine and analyzed with respect to changes in GTPase activity, nucleotide release rate, GDP affinity and structural alterations. We conclude that the identity of the residue at this position in the G5 loop plays a key role in the nucleotide release rate by allowing the correct positioning and hydrogen bonding of the nucleotide base. © 2014 FEBS.

  17. Liquid Effluent Monitoring Information System test plans releases 2.0 and 3.0

    International Nuclear Information System (INIS)

    Guettler, D.A.

    1995-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  18. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.0

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  19. Liquid Effluent Monitoring Information System test plans release 1.2

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  20. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.1

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  1. Materials interactions test methods to measure radionuclide release from waste forms under repository-relevant conditions

    International Nuclear Information System (INIS)

    Strickert, R.G.; Erikson, R.L.; Shade, J.W.

    1984-10-01

    At the request of the Basalt Waste Isolation Project, the Materials Characterization Center has collected and developed a set of procedures into a waste form compliance test method (MCC-14.4). The purpose of the test is to measure the steady-state concentrations of specified radionuclides in solutions contacting a waste form material. The test method uses a crushed waste form and basalt material suspended in a synthetic basalt groundwater and agitated for up to three months at 150 0 C under anoxic conditions. Elemental and radioisotopic analyses are made on filtered and unfiltered aliquots of the solution. Replicate experiments are performed and simultaneous tests are conducted with an approved test material (ATM) to help ensure precise and reliable data for the actual waste form material. Various features of the test method, equipment, and test conditions are reviewed. Experimental testing using actinide-doped borosilicate glasses are also discussed. 9 references, 2 tables

  2. The specification of cross exchange rate equations used to test Purchasing Power Parity

    OpenAIRE

    Hunter, J; Simpson, M

    2004-01-01

    The Article considers the speciÞcation of models used to test Pur- chasing Power Parity when applied to cross exchange rates. SpeciÞcally, conventional dynamic models used to test stationarity of the real exchange rate are likely to be misspeciÞed, except when the parameters of each ex- change rate equation are the same

  3. Experiments to determine the rate of beta energy release following fission of Pu239 andU235 in a fast reactor

    International Nuclear Information System (INIS)

    Murphy, M.F.; Taylor, W.H.; Sweet, D.W.; March, M.R.

    1979-02-01

    Measurements have been made of the rate of beta energy release from Pu239 and U235 fission fragments over a period of 107 seconds following a 105 second irradiation in the zero-power fast reactor Zebra. Results are compared with predictions using the UKFPDD-1 decay data file and two different sets of fission product yield data. (author)

  4. Influence of the ionic character of a drug on its release rate from hydrogels based on 2-hydroxyethylmethacrylate and acrylamide synthesized by photopolymerization

    Directory of Open Access Journals (Sweden)

    M. L. Gomez

    2012-03-01

    Full Text Available The influence of the ionic character of a specific drug on its release rate from a hydrogel based on 2-hydroxyethylmethacrylate (HEMA and acrylamide (AAm is analyzed. The hydrogel was synthesized by photopolymerization employing visible light, safranine O (Saf, as sensitizer, and a silsesquioxane functionalized with amine and methacrylate groups (SFMA, as co-initiator and crosslinker. Safranine O (Saf was employed as a model of a cationic drug and the anionic form of resorufin (Rf as a model of an anionic drug. Saf exhibited a larger affinity with functional groups of the hydrogel than that of Rf. This produced a lower loading and a faster release rate of Rf with respect to Saf. Besides, the release rate of Rf followed a Fickian behavior, while that of Saf exhibited a non-Fickian behavior. By hydrolyzing the hydrogel at pH = 13, amide groups supplied by AAm were irreversibly converted into carboxylic acid groups. Higher loadings and slower release rates of Saf from the hydrolyzed hydrogels were observed, making them particularly suitable for the slow drug-delivery of cationic drugs.

  5. Results of Large-Scale Testing on Effects of Anti-Foam Agent on Gas Retention and Release

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Charles W.; Guzman-Leong, Consuelo E.; Arm, Stuart T.; Butcher, Mark G.; Golovich, Elizabeth C.; Jagoda, Lynette K.; Park, Walter R.; Slaugh, Ryan W.; Su, Yin-Fong; Wend, Christopher F.; Mahoney, Lenna A.; Alzheimer, James M.; Bailey, Jeffrey A.; Cooley, Scott K.; Hurley, David E.; Johnson, Christian D.; Reid, Larry D.; Smith, Harry D.; Wells, Beric E.; Yokuda, Satoru T.

    2008-01-03

    The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) will process and treat radioactive waste that is stored in tanks at the Hanford Site. The waste treatment process in the pretreatment facility will mix both Newtonian and non-Newtonian slurries in large process tanks. Process vessels mixing non-Newtonian slurries will use pulse jet mixers (PJMs), air sparging, and recirculation pumps. An anti-foam agent (AFA) will be added to the process streams to prevent surface foaming, but may also increase gas holdup and retention within the slurry. The work described in this report addresses gas retention and release in simulants with AFA through testing and analytical studies. Gas holdup and release tests were conducted in a 1/4-scale replica of the lag storage vessel operated in the Pacific Northwest National Laboratory (PNNL) Applied Process Engineering Laboratory using a kaolin/bentonite clay and AZ-101 HLW chemical simulant with non-Newtonian rheological properties representative of actual waste slurries. Additional tests were performed in a small-scale mixing vessel in the PNNL Physical Sciences Building using liquids and slurries representing major components of typical WTP waste streams. Analytical studies were directed at discovering how the effect of AFA might depend on gas composition and predicting the effect of AFA on gas retention and release in the full-scale plant, including the effects of mass transfer to the sparge air. The work at PNNL was part of a larger program that included tests conducted at Savannah River National Laboratory (SRNL) that is being reported separately. SRNL conducted gas holdup tests in a small-scale mixing vessel using the AZ-101 high-level waste (HLW) chemical simulant to investigate the effects of different AFAs, their components, and of adding noble metals. Full-scale, single-sparger mass transfer tests were also conducted at SRNL in water and AZ-101 HLW simulant to provide data for PNNL

  6. Calculated concentrations of any radionuclide deposited on the ground by release from underground nuclear detonations, tests of nuclear rockets, and tests of nuclear ramjet engines

    International Nuclear Information System (INIS)

    Hicks, H.G.

    1981-11-01

    This report presents calculated gamma radiation exposure rates and ground deposition of related radionuclides resulting from three types of event that deposited detectable radioactivity outside the Nevada Test Site complex, namely, underground nuclear detonations, tests of nuclear rocket engines and tests of nuclear ramjet engines

  7. New polyvinyl chloride (PVC) nanocomposite consisting of aromatic polyamide and chitosan modified ZnO nanoparticles with enhanced thermal stability, low heat release rate and improved mechanical properties

    Science.gov (United States)

    Hajibeygi, Mohsen; Maleki, Mahdiye; Shabanian, Meisam; Ducos, Franck; Vahabi, Henri

    2018-05-01

    New ternary nanocomposite systems containing polylvinyl chloride (PVC), chitosan modified ZnO (CMZN) nanoparticles and new synthesized polyamide (PA) were designed and prepared by solution casting method. As a potential reinforcement, CMZN was used in PVC system combined with and without PA. Morphology, mechanical, thermal and combustion properties of the all PVC systems were studied. In the presence of the CMZN, PA showed a synergistic effect on improvement of the all investigated properties of PVC. The 5 mass% loss temperature (T5) was increased from 195 °C to 243 °C in PVC/CMZN-PA nanocomposite containing 1 mass% of each PA and CMZN (PZP 2). The peak of heat release rate was decreased from 131 W/g for PVC to 104 W/g for PVC/CMZN-PA nanocomposite containing 3 mass% of each PA and CMZN (PZP 6). According to the tensile tests, compared to the neat PVC, the tensile strength was increased from 35.4 to 53.4 MPa for PZP 6.

  8. Sub-100 nm biodegradable nanoparticles: in vitro release features and toxicity testing in 2D and 3D cell cultures

    International Nuclear Information System (INIS)

    Biondi, Marco; Guarnieri, Daniela; Yu Hui; Belli, Valentina; Netti, Paolo Antonio

    2013-01-01

    A big challenge in tumor targeting by nanoparticles (NPs), taking advantage of the enhanced permeability and retention effect, is the fabrication of small size devices for enhanced tumor penetration, which is considered fundamental to improve chemotherapy efficacy. The purposes of this study are (i) to engineer the formulation of doxorubicin-loaded poly(d,l-lactic-co-glycolic acid) (PLGA)–block–poly(ethylene glycol) (PEG) NPs to obtain <100 nm devices and (ii) to translate standard 2D cytotoxicity studies to 3D collagen systems in which an initial step gradient of the NPs is present. Doxorubicin release can be prolonged for days to weeks depending on the NP formulation and the pH of the release medium. Sub-100 nm NPs are effectively internalized by HeLa cells in 2D and are less cytotoxic than free doxorubicin. In 3D, <100 nm NPs are significantly more toxic than larger ones towards HeLa cells, and the cell death rate is affected by the contributions of drug release and device transport through collagen. Thus, the reduction of NP size is a fundamental feature from both a technological and a biological point of view and must be properly engineered to optimize the tumor response to the NPs. (paper)

  9. Airborne release fractions/rates and respirable fractions for nonreactor nuclear facilities. Volume 1, Analysis of experimental data

    International Nuclear Information System (INIS)

    1994-12-01

    This handbook contains (1) a systematic compilation of airborne release and respirable fraction experimental data for nonreactor nuclear facilities, (2) assessments of the data, and (3) values derived from assessing the data that may be used in safety analyses when the data are applicable. To assist in consistent and effective use of this information, the handbook provides: identification of a consequence determination methodology in which the information can be used; discussion of the applicability of the information and its general technical limits; identification of specific accident phenomena of interest for which the information is applicable; and examples of use of the consequence determination methodology and airborne release and respirable fraction information

  10. Determination by a CFD code of the heat release rate in a confined and mechanically-ventilated compartment fire

    International Nuclear Information System (INIS)

    Nasr, Ayoub

    2011-01-01

    For several years, many experimental/numerical research programs have been carried out at IRSN in order to provide sufficient data on the burning process and understand the behavior of a pool fire in a confined and mechanically ventilated compartment. Several experimental tests have shown that in some cases, the oxygen concentration in the local decreases then stabilizes until fire extinction. The fuel mass loss rate is instantaneously adjusted according to the ventilation in the local, which may leads to a lower fuel consumption rate as compared to that in free atmosphere. The fire duration is then 2 to 3 times greater than that obtained in free atmosphere, which may damages some specific safety equipment used to reduce the spread of fire between compartments such as fire doors. The objective of this work is to propose a theoretical approach that allows the determination of the burning rate of fuels for pool fires in a closed compartment. Fuel response to vitiated air as well as burning enhancement due to hot gases and confinement should be taken into account. Thus, a theoretical formulation, based on an energy balance equation at the pool fire surface, was developed and compared with the empirical correlation of Peatross and Beyler before being implemented in a CFD code 'ISIS', developed at IRSN and validated against PRISME fire test results. The main advantage of this global approach is that no assumptions were made on the relative importance of each mode of heat transfer from the flame. In fact, the convective and the radiant components of the heat flux from the flame to the fuel surface were determined taking into account the air vitiation effect. In addition to this theoretical approach, an experimental work was conducted at the Institut PPRIME to study heptane pool fires in a reduced-scale fire compartment, in the aim to investigate the effects of vitiated air on fire parameters. These results were used to validate the theoretical formulation developed

  11. Handbook for the Release of Test Data. The Office of Research Report Series.

    Science.gov (United States)

    Anderson, Lorin W.

    Several questions are frequently asked by parents and news media regarding the purpose, content, and interpretation of the Comprehensive Tests of Basic Skills (CTBS)--the achievement battery currently used in South Carolina assessment programs. Proper interpretation of the CTBS, or any school district testing program, requires a sound…

  12. A GTPase chimera illustrates an uncoupled nucleotide affinity and release rate, Providing insight into the activation mechanism

    DEFF Research Database (Denmark)

    Guilfoyle, Amy P.; Deshpande, Chandrika N.; Font Sadurni, Josep

    2014-01-01

    , biophysical studies on both the eukaryotic Gα proteins and the GTPase domain (NFeoB) of prokaryotic FeoB proteins have revealed conformational changes in the G5 loop that accompany nucleotide binding and release. However, it is unclear whether this conformational change in the G5 loop is a prerequisite...

  13. Test Method for High β Particle Emission Rate of 63Ni Source Plate

    OpenAIRE

    ZHANG Li-feng

    2015-01-01

    For the problem of measurement difficulties of β particle emission rate of Ni-63 source plate used for Ni-63 betavoltaic battery, a relative test method of scintillation current method was erected according to the measurement principle of scintillation detector.β particle emission rate of homemade Ni-63 source plate was tested by the method, and the test results were analysed and evaluated, it was initially thought that scintillation current method was a feasible way of testing β particle emi...

  14. Use of the Dexamethasone-Corticotrophin Releasing Hormone Test to Assess Hypothalamic-Pituitary-Adrenal Axis Function in Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Eman A. Hasan

    2009-01-01

    Full Text Available Objectives. Hypothalamic-Pituitary-Adrenal axis function may be abnormal in rheumatoid arthritis (RA. A pilot study in 7 patients suggested impaired glucocorticoid feedback in some patients after the dexamethasone-corticotrophin releasing hormone (CRH test. This study aimed to investigate the dexamethasone-corticotrophin releasing factor test in a larger group of patients and relate the results to characteristics of the disease. Methods. Outpatients with active RA (≥3 swollen and tender joints and C-reactive protein > 10 mg/L took dexamethasone (1.5 mg at 23:00 hour in the evening. Next day, baseline saliva and plasma samples were collected, CRH was infused at 11:00 hour, and 4 serial blood and saliva samples were collected. Plasma samples were stored at −80∘C and a radioimmunoassay performed for saliva and plasma cortisol. Results. All 20 participants showed normal dexamethasone suppression and mounted no response to the CRH challenge. In samples with measurable cortisol, there was a strong correlation between saliva and plasma values (r = 0.876, n = 26, P<.01. Conclusion. No abnormalities were found in the Dexamethasone-CRH test in RA patients in contrast to a previous pilot study. Salivary cortisol measurement may offer an alternative noninvasive technique to plasma cortisol in RA patients in future studies.

  15. EPA Releases Draft Policy to Reduce Animal Testing for Skin Sensitization

    Science.gov (United States)

    The document, Draft Interim Science Policy: Use of Alternative Approaches for Skin Sensitization as a Replacement for Laboratory Animal Testing, describes the science behind the non-animal alternatives that can now be used to identify skin sensitization.

  16. Evaluation of food contamination and health risks caused by radioactive fallout released from atmospheric nuclear detonation tests

    International Nuclear Information System (INIS)

    Shimada, Yoko; Ito, Yoshihiko; Yoneda, Minoru; Morisawa, Shinsuke

    2011-01-01

    Before Fukushima Daiichi nuclear disaster, radionuclide like 137 Cs released from atmospheric nuclear detonation tests and Chernobyl disaster has been transported worldwide in the environment and finally taken up by humans through various pathways. In this research, dietary intake of 137 Cs and the related health risks to Japanese caused by chronic global radioactive food contamination from 1945 to 2010 were evaluated by using the mathematical model for the evaluation of global distribution of 137 Cs with food ingestion and domestic and international food supply model. The results of this evaluation can show a background situation before Fukushima disaster and give important information for the risk assessment of this disaster. (author)

  17. Dose-rate conversion factors for external exposure to photon and electron radiation from radionuclides occurring in routine releases from nuclear fuel cycle facilities

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1980-01-01

    Dose-rate conversion factors for external exposure to photon and electron radiation are calculated for 240 radionuclides of potential importance in routine releases from nuclear fuel cycle facilities. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each exposure mode, dose-rate conversion factors for photons and electrons are calculated for tissue-equivalent material at the body surface of an exposed individual. Dose-rate conversion factors for photons only are calculated for 22 body organs. (author)

  18. Closure Report for Corrective Action Unit 340: NTS Pesticide Release Sites Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    C. M. Obi

    2000-05-01

    The purpose of this report is to provide documentation of the completed corrective action and to provide data confirming the corrective action. The corrective action was performed in accordance with the approved Corrective Action Plan (CAP) (U.S. Department of Energy [DOE], 1999) and consisted of clean closure by excavation and disposal. The Area 15 Quonset Hut 15-11 was formerly used for storage of farm supplies including pesticides, herbicides, and fertilizers. The Area 23 Quonset Hut 800 was formerly used to clean pesticide and herbicide equipment. Steam-cleaning rinsate and sink drainage occasionally overflowed a sump into adjoining drainage ditches. One ditch flows south and is referred to as the quonset hut ditch. The other ditch flows southeast and is referred to as the inner drainage ditch. The Area 23 Skid Huts were formerly used for storing and mixing pesticide and herbicide solutions. Excess solutions were released directly to the ground near the skid huts. The skid huts were moved to a nearby location prior to the site characterization performed in 1998 and reported in the Corrective Action Decision Document (CADD) (DOE, 1998). The vicinity and site plans of the Area 23 sites are shown in Figures 2 and 3, respectively.

  19. Validation of basophil histamine release against the autologous serum skin test and outcome of serum-induced basophil histamine release studies in a large population of chronic urticaria patients

    DEFF Research Database (Denmark)

    Platzer, M H; Grattan, C E H; Poulsen, Lars K.

    2005-01-01

    the immunoglobulin E (IgE) or the high affinity IgE receptor (FcepsilonRI) and serum-induced histamine release (HR) from basophils and mast cells. We have examined the correlation between the ASST and a new basophil histamine-releasing assay (the HR-Urtikaria test) in a group of well-characterized CU patients...... and subsequently determined the frequency of HR-Urticaria-positive sera from a larger population of CU patients....

  20. Auditing HIV Testing Rates across Europe: Results from the HIDES 2 Study.

    Directory of Open Access Journals (Sweden)

    D Raben

    Full Text Available European guidelines recommend the routine offer of an HIV test in patients with a number of AIDS-defining and non-AIDS conditions believed to share an association with HIV; so called indicator conditions (IC. Adherence with this guidance across Europe is not known. We audited HIV testing behaviour in patients accessing care for a number of ICs. Participating centres reviewed the case notes of either 100 patients or of all consecutive patients in one year, presenting for each of the following ICs: tuberculosis, non-Hodgkins lymphoma, anal and cervical cancer, hepatitis B and C and oesophageal candidiasis. Observed HIV-positive rates were applied by region and IC to estimate the number of HIV diagnoses potentially missed. Outcomes examined were: HIV test rate (% of total patients with IC, HIV test accepted (% of tests performed/% of tests offered and new HIV diagnosis rate (%. There were 49 audits from 23 centres, representing 7037 patients. The median test rate across audits was 72% (IQR 32-97, lowest in Northern Europe (median 44%, IQR 22-68% and highest in Eastern Europe (median 99%, IQR 86-100. Uptake of testing was close to 100% in all regions. The median HIV+ rate was 0.9% (IQR 0.0-4.9, with 29 audits (60.4% having an HIV+ rate >0.1%. After adjustment, there were no differences between regions of Europe in the proportion with >0.1% testing positive (global p = 0.14. A total of 113 patients tested HIV+. Applying the observed rates of testing HIV+ within individual ICs and regions to all persons presenting with an IC suggested that 105 diagnoses were potentially missed. Testing rates in well-established HIV ICs remained low across Europe, despite high prevalence rates, reflecting missed opportunities for earlier HIV diagnosis and care. Significant numbers may have had an opportunity for HIV diagnosis if all persons included in IC audits had been tested.

  1. 76 FR 80781 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2012

    Science.gov (United States)

    2011-12-27

    ...-11213, Notice No. 15] RIN 2130-AA81 Alcohol and Drug Testing: Determination of Minimum Random Testing...: Lamar Allen, Alcohol and Drug Program Manager, Office of Safety Enforcement, Mail Stop 25, Federal... Kathy Schnakenberg, FRA Alcohol/Drug Program Specialist, (telephone (719) 633-8955). Issued in...

  2. Screening of latent tuberculosis infection among health care workers working in Hajj pilgrimage area in Saudi Arabia, using interferon gamma release assay and tuberculin skin test.

    Science.gov (United States)

    Bukhary, Zakeya A; Amer, Soliman M; Emara, Magdy M; Abdalla, Mohammad E; Ali, Sahar A

    2018-01-01

    Interferon gamma release assays (IGRA) is highly specific for Mycobacterium tuberculosis and is the preferred test in BCG-vaccinated individuals. The few studies that have screened health care workers (HCWs) in Saudi Arabia for latent tuberculosis infection (LTBI) using IGRA have varied in agreement with the traditional tuberculin skin test (TST). Assess the prevalence of LTBI among HCWs working in the Hajj pilgrimage using IGRA and TST and measuring their agreement. Cross-sectional prospective. Multiple non-tertiary care hospitals. HCWs who worked during the Hajj pilgrimage in Saudi Arabia in December 2015. Data was collected by standarized questionnaire. Samples were drawn and analyzed by standard methods. The prevalence of LTBI among HCW and the agreement by kappa statistic between QFT-GIT and TST. 520 subjects. Nurses accounted for 30.7% of the sample and physicians, 19.2%. The majority were BCG vaccinated (98.5%). There were a total of 56 positive by QFT-GIT and the LTBI rate was 10.8%. In 50 QFT positive/476 TST negative the LTBI rate was 10.5% in discordant tests, and in 6 QFT positive/44 TST positive it was 13.6% in concordant tests. The overall agreement between both tests was poor-83% and kappa was 0.02. LTBI prevalence was associated with longer employment (13.1 [9.2] years). The QFT-GIT positive test was significantly higher in physicians (P=.02) and in HCWs working in chest hospitals 16/76 (21.05%) (P=.001). Agreement between the tests was poor. QFT-GIT detected LTBI when TST was negative in HCWs who had a history of close contact with TB patients. A second step TST was not feasible within 2-3 weeks. None.

  3. Effect of hydrophilicity of carbon nanotube arrays on the release rate and activity of recombinant human bone morphogenetic protein-2

    Energy Technology Data Exchange (ETDEWEB)

    Han Zhaojun; Ostrikov, Kostya [Plasma Nanoscience Centre Australia (PNCA), CSIRO Materials Science and Engineering, Lindfield, New South Wales 2070 (Australia); Tan, Cher Ming; Tay, Beng Kang [School of Electrical and Electronic Engineering, Nanyang Technological University, 639798 (Singapore); Peel, Sean A F, E-mail: zhaojun.han@csiro.au [Department of Dentistry, University of Toronto, Toronto, ON, M5G 1G6 (Canada)

    2011-07-22

    Novel nanostructures such as vertically aligned carbon nanotube (CNT) arrays have received increasing interest as drug delivery carriers. In the present study, two CNT arrays with extreme surface wettabilities are fabricated and their effects on the release of recombinant human bone morphogenetic protein-2 (rhBMP-2) are investigated. It is found that the superhydrophilic arrays retained a larger amount of rhBMP-2 than the superhydrophobic ones. Further use of a poloxamer diffusion layer delayed the initial burst and resulted in a greater total amount of rhBMP-2 released from both surfaces. In addition, rhBMP-2 bound to the superhydrophilic CNT arrays remained bioactive while they denatured on the superhydrophobic surfaces. These results are related to the combined effects of rhBMP-2 molecules interacting with poloxamer and the surface, which could be essential in the development of advanced carriers with tailored surface functionalities.

  4. High Rates of Police Detention Among Recently Released HIV-infected Prisoners in Ukraine: Implications for Health Outcomes

    Science.gov (United States)

    Izenberg, Jacob M.; Bachireddy, Chethan; Soule, Michael; Kiryazova, Tetiana; Dvoryak, Sergey; Altice, Frederick L.

    2013-01-01

    Background Ukraine’s HIV epidemic, primarily affecting people who inject drugs (PWID), is expanding and transitioning despite free opioid substitution therapy (OST) and antiretroviral therapy (ART), two effective ways to reduce HIV transmission. Police detention not resulting in imprisonment, defined as police harassment, of PWID is common, but its prevalence and impact on health is not known. Method HIV-infected individuals (N=97) released from prison within one year were recruited and surveyed in two HIV-endemic Ukrainian cities about post-release police detention experiences. Data on the frequency of police detention, related adverse events, and impact on OST and ART continuity were collected, and correlates of detention were examined using logistic regression. Results Detention responses were available for 94 (96.9%) participants, of which 55 (58.5%) reported police detentions (mean=9.4 per person-year). For those detained while prescribed OST (N=28) and ART (N=27), medication interruption was common (67.9% and 70.4%, respectively); 23 of 27 participants prescribed OST (85.2%) were detained en route to/from OST treatment. Significant independent correlates of detention without charges included post-release ART prescription (AOR 4.98, p=0.021), current high-risk injection practices (AOR 5.03, p=0.011), male gender (AOR 10.88, p=0.010), and lower lifetime months of imprisonment (AOR 0.99, p=0.031). Conclusions HIV-infected individuals recently released from prison in Ukraine experience frequent police detentions, resulting in withdrawal symptoms, confiscation of syringes, and interruptions of essential medications, including ART and OST. Structural changes are urgently needed to reduce police detentions in order to control HIV transmission and improve both individual and public health. PMID:23769160

  5. Tailoring the degradation rate and release kinetics from poly(galactitol sebacate) by blending with chitosan, alginate or ethyl cellulose.

    Science.gov (United States)

    Natarajan, Janeni; Madras, Giridhar; Chatterjee, Kaushik

    2016-12-01

    Despite significant advances in recent times, the investigation of discovering a perfect biomaterial is perennial. In this backdrop, blending of natural and synthetic polymers is gaining popularity since it is the easiest way to complement the drawbacks and attain a superlative material. Based on this, the objective of this study was to synthesize a novel polyester, poly(galactitol sebacate), and subsequently blend this polymer with one of the three natural polymers such as alginate, chitosan or ethyl cellulose. FT-IR showed the presence of both the polymers in the blends. 1 H NMR confirmed the chemical structure of the synthesized poly (galactitol sebacate). Thermal characterization was performed by DSC revealing that the polymers were amorphous in nature and the glass transition temperatures increased with the increase in ratio of the natural polymers in the blends. SEM imaging showed that the blends were predominantly homogeneous. Contact angle measurements demonstrated that the blending imparted the hydrophilic nature into poly (galactitol sebacate) when blending with alginate or chitosan and hydrophobic when blending with ethyl cellulose. In vitro hydrolytic degradation studies and dye release studies indicated that the polymers became more hydrophilic in alginate and chitosan blends and thus accelerated the degradation and release process. The reverse trend was observed in the case of ethyl cellulose blends. Modeling elucidated that the degradation and dye release followed first order kinetics and Higuchi kinetics, respectively. In vitro cell studies confirmed the cytocompatible nature of the blends. It can be proposed that the chosen natural polymers for blending showed wide variations in hydrophilicity resulting in tailored degradation, release and cytocompatibility properties and thus are promising candidates for use in drug delivery and tissue engineering. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Abrasion Testing of Products Containing Nanomaterials, SOP-R-2: Scientific Operating Procedure Series: Release (R)

    Science.gov (United States)

    2016-04-01

    Nanotechnologies -- Terminology and definitions for nano-objects -- Nanoparticle, nanofibre and nanoplate Definitions Abrasion - wearing away...ER D C SR -1 6- 2 Environmental Consequences of Nanotechnologies Abrasion Testing of Products Containing Nanomaterials, SOP-R-2...ERDC online library at http://acwc.sdp.sirsi.net/client/default. Environmental Consequences of Nanotechnologies ERDC SR-16-2 April 2016

  7. Use of leaching tests to quantify trace element release from waste to energy bottom ash amended pavements.

    Science.gov (United States)

    Roessler, Justin G; Townsend, Timothy G; Ferraro, Christopher C

    2015-12-30

    A series of roadway tests strips were paved on-site at a landfill in Florida, U.S. Waste to energy (WTE) bottom ash was used as a partial course aggregate replacement in a hot mix asphalt (HMA) and a Portland cement concrete (PCC) pavement, along with control HMA and PCC sections. This allowed for a comparison of the relative degree of leaching between both materials (HMA and PCC) as well as between the ash-amended and control pavements. Batch and monolithic tank leaching tests were conducted on the pavements. Testing of the PCC samples demonstrated that Mo and Al were elevated above regulatory thresholds for both the control and ash amended samples. Further leach testing demonstrated that the release of Mo was likely from the PCC and not a result of the inclusion of the BA into pavement. Batch leach testing of ash-amended HMA samples revealed Sb as a constituent of potential concern. The results of the monolith leaching test displayed leaching of Sb within the same order of magnitude as the regulatory threshold. Calculation of the leachability index (LI) for Sb found that it would have limited mobility when incorporated in the HMA matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Using An Adapter To Perform The Chalfant-Style Containment Vessel Periodic Maintenance Leak Rate Test

    International Nuclear Information System (INIS)

    Loftin, B.; Abramczyk, G.; Trapp, D.

    2011-01-01

    Recently the Packaging Technology and Pressurized Systems (PT and PS) organization at the Savannah River National Laboratory was asked to develop an adapter for performing the leak-rate test of a Chalfant-style containment vessel. The PT and PS organization collaborated with designers at the Department of Energy's Pantex Plant to develop the adapter currently in use for performing the leak-rate testing on the containment vessels. This paper will give the history of leak-rate testing of the Chalfant-style containment vessels, discuss the design concept for the adapter, give an overview of the design, and will present results of the testing done using the adapter.

  9. 78 FR 41129 - Market Test of Experimental Product - International Merchandise Return Service-Non-Published Rates

    Science.gov (United States)

    2013-07-09

    ...--Non-Published Rates AGENCY: U.S. Postal Service\\TM\\. ACTION: Notice. SUMMARY: The Postal Service hereby gives notice of a market test for International Merchandise Return Service--Non-Published Rates in... Return Service (IMRS) Non-published Rate (NPR) experimental product on August 15, 2013. The Postal...

  10. 3D finite element analysis of stress distributions and strain energy release rates for adhesive bonded flat composite lap shear joints having pre-existing delaminations

    Energy Technology Data Exchange (ETDEWEB)

    Parida, S. K.; Pradhan, A. K. [Indian Institute of Technology, Bhubaneswar (India)

    2014-02-15

    The rate of propagation of embedded delamination in the strap adherend of lap shear joint (LSJ) made of carbon/epoxy composites has been evaluated employing three-dimensional non-linear finite elements. The delamination has been presumed to pre-exist in the thin resin layer between the first and second plies of the strap adherend. The inter-laminar peel and shear stress distributions have been studied in details and are seen to be predominantly three-dimensional in nature. The components of strain energy release rate (SERR) corresponding to the opening, sliding and cross sliding modes of delamination are significantly different at the two fronts of the embedded delamination. The sequential release of multi-point constraint (MPC) finite elements in the vicinity of the delamination fronts enables to simulate the growth of the delamination at either ends. This simulation procedure can be utilized effectively for evaluation of the status of the structural integrity of the bonded joints.

  11. Field Test Evaluation of Effect on Cone Resistance Caused by Change in Penetration Rate

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2012-01-01

    in the laboratory. A change in the measured cone resistance occurs by lowering the penetration rate. This is caused by the changes in drainage conditions. Compared to the normal penetration rate of 20 mm/s, this paper illustrates that lowering the penetration rate leads to an increase in the cone resistance from 1......This paper presents how a change in cone penetration rate affects the measured cone resistance during cone penetration testing in silty soils. Regardless of soil, type the standard rate of penetration is 20 mm/s and it is generally accepted that undrained penetration occurs in clay while drained...... penetration occurs in sand. In intermediate soils such as silty soils, the standard cone penetration rate may result in drainage conditions varying from undrained to partially or fully drained conditions. Field cone penetrations tests have been conducted with different penetration rates on a test site...

  12. Testing of Monitoring Devices for JP-4 Releases in the Subsurface

    Science.gov (United States)

    1990-04-01

    tests conducted to study the effectiveness, advantages , and limitations of a set of devices. All of the devices (except FiberChem) evaluated are...1,000 ppm and 1 percent butane standards ( Alltech Associates, Inc., Deerfield, Illinois). b. Temperature Program Analysis Two different temperature...in place. The advantage of having the probe is that we did not have to calculate or measure the liquid volume displaced by the probe. The accuracy of

  13. The Plinius/Colima CA-U3 test on fission-product aerosol release over a VVER-type corium pool

    International Nuclear Information System (INIS)

    Journeau, Ch.; Piluso, P.; Correggio, P.; Godin-Jacqmin, L.

    2007-01-01

    In a hypothetical case of severe accident in a PWR type VVER-440, a complex corium pool could be formed and fission products could be released. In order to study aerosols release in terms of mechanisms, kinetics, nature or quantity, and to better precise the source term of VVER-440, a series of experiments have been performed in the Colima facility and the test Colima CA-U3 has been successfully performed thanks to technological modifications to melt a prototypical corium at 2760 C degrees. Specific instrumentation has allowed us to follow the evolution of the corium melt and the release, transport and deposition of the fission products. The main conclusions are: -) there is a large release of Cr, Te, Sr, Pr and Rh (>95%w), -) there is a significant release of Fe (50%w), -) there is a small release of Ba, Ce, La, Nb, Nd and Y (<90%w), -) there is a very small release of U in proportion (<5%w) but it is one of the major released species in mass, and -) there is no release of Zr. The Colima experimental results are consistent with previous experiments on irradiated fuels except for Ba, Fe and U releases. (A.C.)

  14. Measurement uncertainty of dissolution test of acetaminophen immediate release tablets using Monte Carlo simulations

    Directory of Open Access Journals (Sweden)

    Daniel Cancelli Romero

    2017-10-01

    Full Text Available ABSTRACT Analytical results are widely used to assess batch-by-batch conformity, pharmaceutical equivalence, as well as in the development of drug products. Despite this, few papers describing the measurement uncertainty estimation associated with these results were found in the literature. Here, we described a simple procedure used for estimating measurement uncertainty associated with the dissolution test of acetaminophen tablets. A fractionate factorial design was used to define a mathematical model that explains the amount of acetaminophen dissolved (% as a function of time of dissolution (from 20 to 40 minutes, volume of dissolution media (from 800 to 1000 mL, pH of dissolution media (from 2.0 to 6.8, and rotation speed (from 40 to 60 rpm. Using Monte Carlo simulations, we estimated measurement uncertainty for dissolution test of acetaminophen tablets (95.2 ± 1.0%, with a 95% confidence level. Rotation speed was the most important source of uncertainty, contributing about 96.2% of overall uncertainty. Finally, it is important to note that the uncertainty calculated in this paper reflects the expected uncertainty to the dissolution test, and does not consider variations in the content of acetaminophen.

  15. Acceptance test procedure for the 105-KW isolation barrier leak rate

    International Nuclear Information System (INIS)

    McCracken, K.J.

    1995-01-01

    This acceptance test procedure shall be used to: First establish a basin water loss rate prior to installation of the two isolation barriers between the main basin and the discharge chute in K-Basin West. Second, perform an acceptance test to verify an acceptable leakage rate through the barrier seals. This Acceptance Test Procedure (ATP) has been prepared in accordance with CM-6-1 EP 4.2, Standard Engineering Practices

  16. Validation of new CFD release by Ground-Coupled Heat Transfer Test Cases

    Directory of Open Access Journals (Sweden)

    Sehnalek Stanislav

    2017-01-01

    Full Text Available In this article is presented validation of ANSYS Fluent with IEA BESTEST Task 34. Article stars with outlook to the topic, afterward are described steady-state cases used for validation. Thereafter is mentioned implementation of these cases on CFD. Article is concluded with presentation of the simulated results with a comparison of those from already validated simulation software by IEA. These validation shows high correlation with an older version of tested ANSYS as well as with other main software. The paper ends by discussion with an outline of future research.

  17. Pre-service proof pressure and leak rate tests for the Qinshan CANDU project reactor buildings

    International Nuclear Information System (INIS)

    Petrunik, K.J.; Khan, A.; Ricciuti, R.; Ivanov, A.; Chen, S.

    2003-01-01

    The Qinshan CANDU Project Reactor Buildings (Units 1 and 2) have been successfully tested for the Pre-Service Proof Pressure and Integrated Leak Rate Tests. The Unit 1 tests took place from May 3 to May 9, 2002 and from May 22 to May 25, 2002, and the Unit 2 tests took place from January 21 to January 27, 2003. This paper discusses the significant steps taken at minimum cost on the Qinshan CANDU Project, which has resulted in a) very good leak rate (0.21%) for Unit 1 and excellent leak rate (0.130%) for Unit 2; b) continuous monitoring of the structural behaviour during the Proof Pressure Test, thus eliminating any repeat of the structural test due to lack of data; and c) significant schedule reduction achieved for these tests in Unit 2. (author)

  18. Characterization of strain rate sensitivity and activation volume using the indentation relaxation test

    International Nuclear Information System (INIS)

    Xu Baoxing; Chen Xi; Yue Zhufeng

    2010-01-01

    We present the possibility of extracting the strain rate sensitivity, activation volume and Helmholtz free energy (for dislocation activation) using just one indentation stress relaxation test, and the approach is demonstrated with polycrystalline copper. The Helmholtz free energy measured from indentation relaxation agrees well with that from the conventional compression relaxation test, which validates the proposed approach. From the indentation relaxation test, the measured indentation strain rate sensitivity exponent is found to be slightly larger, and the indentation activation volume much smaller, than their counterparts from the compression test. The results indicate the involvement of multiple dislocation mechanisms in the indentation test.

  19. The influence of data collection rate, containment size and data smoothing on containment Integrated Leak Rate Tests

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.E.; Lurie, D.

    1988-01-01

    Phase I of a U.S. Nuclear Regulatory Commission contract investigated nuclear power plant Integrated Leak Rate Tests (ILRTs) using data gathered at many domestic and foreign ILRTs. The study evaluated ILRTs with the ANS criteria (in ANSI/ANS-56.8-1987) and the proposed extended ANS criteria (in draft Regulatory Guide, Task MS 021-5, October 1986). The study considered (1) the effects of data collection rates on ILRT conclusions, (2) a possible relationship between containment size, data collection rate and ILRT duration, (3) the impact of the proposed extended ANS methodology on ILRTs, and (4) the influence of data smoothing on ILRT data. The study was performed using 20 sets of Type A and 17 sets of verification data

  20. Study of creep behaviour in P-doped copper with slow strain rate tensile tests

    International Nuclear Information System (INIS)

    Xuexing Yao; Sandstroem, Rolf

    2000-08-01

    Pure copper with addition of phosphorous is planned to be used to construct the canisters for spent nuclear fuel. The copper canisters can be exposed to a creep deformation up to 2-4% at temperatures in services. The ordinary creep strain tests with dead weight loading are generally employed to study the creep behaviour; however, it is reported that an initial plastic deformation of 5-15% takes place when loading the creep specimens at lower temperatures. The slow strain rate tensile test is an alternative to study creep deformation behaviour of materials. Ordinary creep test and slow strain rate tensile test can give the same information in the secondary creep stage. The advantage of the tensile test is that the starting phase is much more controlled than in a creep test. In a tensile test the initial deformation behaviour can be determined and the initial strain of less than 5% can be modelled. In this study slow strain rate tensile tests at strain rate of 10 -4 , 10 -5 , 10 -6 , and 10 -7 /s at 75, 125 and 175 degrees C have been performed on P-doped pure Cu to supplement creep data from conventional creep tests. The deformation behaviour has successfully been modelled. It is shown that the slow strain rate tensile tests can be implemented to study the creep deformation behaviours of pure Cu

  1. Hardware test program for evaluation of baseline range/range rate sensor concept

    Science.gov (United States)

    Pernic, E.

    1985-01-01

    The test program Phase II effort provides additional design information in terms of range and range rate (R/R) sensor performance when observing and tracking a typical spacecraft target. The target used in the test program was a one-third scale model of the Hubble Space Telescope (HST) available at the MSFC test site where the tests were performed. A modified Bendix millimeter wave radar served as the R/R sensor test bed for evaluation of range and range rate tracking performance, and generation of radar signature characteristics of the spacecraft target. A summary of program test results and conclusions are presented along with detailed description of the Bendix test bed radar with accompaning instrumentation. The MSFC test site and facilities are described. The test procedures used to establish background levels, and the calibration procedures used in the range accuracy tests and RCS (radar cross section) signature measurements, are presented and a condensed version of the daily log kept during the 5 September through 17 September test period is also presented. The test program results are given starting with the RCS signature measurements, then continuing with range measurement accuracy test results and finally the range and range rate tracking accuracy test results.

  2. Hypothalamic amenorrhea with normal body weight: ACTH, allopregnanolone and cortisol responses to corticotropin-releasing hormone test.

    Science.gov (United States)

    Meczekalski, B; Tonetti, A; Monteleone, P; Bernardi, F; Luisi, S; Stomati, M; Luisi, M; Petraglia, F; Genazzani, A R

    2000-03-01

    Hypothalamic amenorrhea (HA) is a functional disorder caused by disturbances in gonadotropin-releasing hormone (GnRH) pulsatility. The mechanism by which stress alters GnRH release is not well known. Recently, the role of corticotropin-releasing hormone (CRH) and neurosteroids in the pathophysiology of HA has been considered. The aim of the present study was to explore further the role of the hypothalamic-pituitary-adrenal axis in HA. We included 8 patients (aged 23.16+/-1.72 years) suffering from hypothalamic stress-related amenorrhea with normal body weight and 8 age-matched healthy controls in the follicular phase of the menstrual cycle. We measured basal serum levels of FSH, LH, and estradiol and evaluated ACTH, allopregnanolone and cortisol responses to CRH test in both HA patients and healthy women. Serum basal levels of FSH, LH, and estradiol as well as basal levels of allopregnanolone were significantly lower in HA patients than in controls (P<0.001) while basal ACTH and cortisol levels were significantly higher in amenorrheic patients with respect to controls (P<0.001). The response (area under the curve) of ACTH, allopregnanolone and cortisol to CRH was significantly lower in amenorrheic women compared with controls (P<0.001, P<0.05, P<0.05 respectively). In conclusion, women with HA, despite the high ACTH and cortisol levels and, therefore, hypothalamus-pituitary-adrenal axis hyperactivity, are characterized by low allopregnanolone basal levels, deriving from an impairment of both adrenal and ovarian synthesis. The blunted ACTH, allopregnanolone and cortisol responses to CRH indicate that, in hypothalamic amenorrhea, there is a reduced sensitivity and expression of CRH receptor. These results open new perspectives on the role of neurosteroids in the pathogenesis of hypothalamic amenorrhea.

  3. Steady-State Flammable Gas Release Rate Calculation And Lower Flammability Level Evaluation For Hanford Tank Waste

    International Nuclear Information System (INIS)

    Hu, T.A.

    2007-01-01

    Assess the steady-state flammability level at normal and off-normal ventilation conditions. The methodology of flammability analysis for Hanford tank waste is developed. The hydrogen generation rate model was applied to calculate the gas generation rate for 177 tanks. Flammability concentrations and the time to reach 25% and 100% of the lower flammability limit, and the minimum ventilation rate to keep from 100 of the LFL are calculated for 177 tanks at various scenarios.

  4. Heat release from wood wall assemblies using oxygen consumption method

    Science.gov (United States)

    Hao C. Tran; Robert E. White

    1990-01-01

    The concept of heat release rate is gaining acceptance in the evaluation of fire performance of materials and assemblies. However, this concept has not been incorporated into fire endurance testing such as the ASTM E-119 test method. Heat release rate of assemblies can be useful in determining the time at which the assemblies start to contribute to the controlled fire...

  5. An evaluation of arsenic release from monolithic solids using a modified semi-dynamic leaching test

    International Nuclear Information System (INIS)

    Dermatas, Dimitris; Moon, Deok Hyun; Menounou, Nektaria; Meng, Xiaoguang; Hires, Richard

    2004-01-01

    Quicklime and quicklime-fly ash-based stabilization/solidification (S/S) effectiveness was evaluated by performing semi-dynamic leaching tests (American Nuclear Society 16.1). Artificial soil samples, contaminated with arsenic trioxide (As 2 O 3 ) as well as field soil samples contaminated with arsenic (As) were tested. The artificial soils were prepared by mixing amounts of kaolinite or montmorillonite with fine quartz sand. The S/S effectiveness was evaluated by measuring effective diffusion coefficients (D e ) and leachability indices (LX). Treatment was most effective in kaolinite-based artificial soils treated with quicklime and in quicklime-fly ash treated field soils. The experimental results indicate that D e values were lowered as a result of S/S treatment. Upon treatment LX values were higher than 9, suggesting that S/S treated soils are acceptable for 'controlled utilization'. Based on a model developed by de Groot and van der Sloot [G.J. de Groot, H.A. van der Sloot, in: T.M. Gilliam, C.C. Wiles (Eds.), Stabilization and Solidification of Hazardous, Radioactive, and Mixed Wastes, vol. 2, ASTM STP 1123, ASTM, PA, 1992, p. 149], the leaching mechanism for all of the treated soils was found to be controlled by diffusion. The effect of soluble silica (Si) on As leachability was also evaluated. When soluble Si concentration was less than 1 ppm, As leachability was the lowest. The controlling mechanism of As immobilization whether sorption, precipitation, or inclusion was also evaluated. It was determined that precipitation was the dominant mechanism

  6. In-core flow rate distribution measurement test of the JOYO irradiation core

    International Nuclear Information System (INIS)

    Suzuki, Toshihiro; Isozaki, Kazunori; Suzuki, Soju

    1996-01-01

    A flow rate distribution measurement test was carried out for the JOYO irradiation core (the MK-II core) after the 29th duty cycle operation. The main object of the test is to confirm the proper flow rate distribution at the final phase of the MK-II core. The each flow rate at the outlet of subassemblies was measured by the permanent magnetic flowmeter inserted avail of fuel exchange hole in the rotating plug. This is third test in the MK-II core, after 10 years absence from the final test (1985). Total of 550 subassemblies were exchanged and accumulated reactor operation time reached up to 38,000 hours from the previous test. As a conclusion, it confirmed that the flow rate distribution has been kept suitable in the final phase of the MK-II core. (author)

  7. Dynamic Brazilian Test of Rock Under Intermediate Strain Rate: Pendulum Hammer-Driven SHPB Test and Numerical Simulation

    Science.gov (United States)

    Zhu, W. C.; Niu, L. L.; Li, S. H.; Xu, Z. H.

    2015-09-01

    The tensile strength of rock subjected to dynamic loading constitutes many engineering applications such as rock drilling and blasting. The dynamic Brazilian test of rock specimens was conducted with the split Hopkinson pressure bar (SHPB) driven by pendulum hammer, in order to determine the indirect tensile strength of rock under an intermediate strain rate ranging from 5.2 to 12.9 s-1, which is achieved when the incident bar is impacted by pendulum hammer with different velocities. The incident wave excited by pendulum hammer is triangular in shape, featuring a long rising time, and it is considered to be helpful for achieving a constant strain rate in the rock specimen. The dynamic indirect tensile strength of rock increases with strain rate. Then, the numerical simulator RFPA-Dynamics, a well-recognized software for simulating the rock failure under dynamic loading, is validated by reproducing the Brazilian test of rock when the incident stress wave retrieved at the incident bar is input as the boundary condition, and then it is employed to study the Brazilian test of rock under the higher strain rate. Based on the numerical simulation, the strain-rate dependency of tensile strength and failure pattern of the Brazilian disc specimen under the intermediate strain rate are numerically simulated, and the associated failure mechanism is clarified. It is deemed that the material heterogeneity should be a reason for the strain-rate dependency of rock.

  8. Effect of Pregnancy on Interferon Gamma Release Assay and Tuberculin Skin Test Detection of Latent TB Infection Among HIV-Infected Women in a High Burden Setting.

    Science.gov (United States)

    LaCourse, Sylvia M; Cranmer, Lisa M; Matemo, Daniel; Kinuthia, John; Richardson, Barbra A; Horne, David J; John-Stewart, Grace

    2017-05-01

    Peripartum immunologic changes may affect latent tuberculosis infection (LTBI) diagnostic performance among HIV-infected women. HIV-infected women were serially tested with tuberculin skin test (TST) and interferon gamma release assay [QuantiFERON TB Gold In-tube (QFT)] in pregnancy and 6 weeks postpartum in Kenya. Prevalence, sensitivity and agreement, and correlates of QFT/TST positivity were assessed. Quantitative QFT mitogen and Mycobacterium tuberculosis antigen (Mtb-Ag) responses were compared by peripartum stage. Incidence of test conversion at 6 weeks postpartum was evaluated in baseline TST-/QFT- women. Among 100 HIV-infected women, median age was 26 years, median CD4 was 555 cells per cubic millimeter, and 88% were on antiretrovirals. More women were QFT+ than TST+ in both pregnancy (35.4% vs. 13.5%, P = 0.001) and postpartum (29.6% vs. 14.8%, P pregnancy vs. postpartum, and specifically among persistently QFT+ women (Mtb-Ag: 3.46 vs. 4.48 IU/mL, P = 0.007). QFT indeterminate rate was higher in pregnancy (16%) compared with postpartum (0%) because of lower mitogen response. QFT identified >2-fold more women with LTBI compared with TST in pregnancy and postpartum. Lower QFT Mtb-Ag and mitogen responses in pregnancy compared with postpartum suggest that pregnancy-associated immunologic changes may influence LTBI test performance.

  9. Development of a general model to predict the rate of radionuclide release (source term) from a low-level waste shallow land burial facility

    International Nuclear Information System (INIS)

    Sullivan, T.M.; Kempf, C.R.; Suen, C.J.; Mughabghab, S.M.

    1988-01-01

    Federal Code of Regulations 10 CFR 61 requires that any near surface disposal site be capable of being characterized, analyzed, and modeled. The objective of this program is to assist NRC in developing the ability to model a disposal site that conforms to these regulations. In particular, a general computer model capable of predicting the quantity and rate of radionuclide release from a shallow land burial trench, i.e., the source term, is being developed. The framework for this general model has been developed and consists of four basic compartments that represent the major processes that influence release. These compartments are: water flow, container degradation, release from the waste packages, and radionuclide transport. Models for water flow and radionuclide transport rely on the use of the computer codes FEMWATER and FEMWASTE. These codes are generally regarded as being state-of-the-art and required little modification for their application to this project. Models for container degradation and release from waste packages have been specifically developed for this project. This paper provides a brief description of the models being used in the source term project and examples of their use over a range of potential conditions. 13 refs

  10. Radiation preparation of drug carriers based on poly(N-isopropylacrylamide) hydrogels, their loading capacities and controlled release rates for dexamethasone and tegafur

    International Nuclear Information System (INIS)

    Hoang Dang Sang; Nguyen Van Binh; Tran Bang Diep; Nguyen Thi Thom; Hoang Phuong Thao; Pham Duy Duong; Tran Minh Quynh

    2015-01-01

    Thermo-sensitive hydrogels have great potential in some applications. In order to use as the drug delivery systems, the hydrogels should be biocompatibility. New polymers with more biocompatibility and better biodegradability, and environmental friendly crosslinking agents would be necessary for the successful drug carriers. Poly (N-isopropylacrylamide-co-dimethylacrylamide) based hydrogels have been prepared from the admixture solutions of N-isopropylacrylamide (NIPA) and N,N’-dimethyl acrylamide (DMA) by radiation copolymerization and crosslinking at radiation dose of 20 kGy as reported in our previous study. Water swelling behaviour of the resulting hydrogels were much depended on their nature such as initial ratio of NIPA and DMA. The drug-loaded hydrogels were prepared by merging hydrogel in the solutions containing corresponding drugs. Loading capacity of the hydrogels were about 48.6 and 95.7 mg per g dried hydrogel for dexamethasone and tegafur. The release studies showed that the presence of ions in simulated body fluid and temperature of the solution much affecting to in vitro release behaviors of hydrogels for dexamethasone and tegafur. The release rates were fast for both drug models. The result also revealed that these drug carriers were biocompatibility without skin irritation, suggested the drug-loaded hydrogels may be used as controlled release drug delivery systems. (author)

  11. C peptide and insulin releasing RIA test for the investigation of β cell function in diabetic patients

    International Nuclear Information System (INIS)

    Shi Ailan; Zhu Chengmo; Wang Qiyu; Wang Ping

    1993-01-01

    Results of C-peptide releasing RIA test in 15 normals, and 100 diabetes were summarized and compared with glucose tolerance test and serum insulin for investigating the characteristics in different types of diabetes and evaluating the functional state of islet β cell. In 36 cases of IDDM the fasting blood sugar was significantly increased, and further elevated after eating of bread, but its peak time delay in 2 hours (normalin 1 hour). The level of basal C-peptide is very low, but shows slightly weak on no response after bread stimulating test, all of this denotes that β cell function of islets severely injured. The increasing of fasting blood sugar in 64 cases of NIDDM was lower than those of IDDM. Fasting C-peptide and insulin was normal or increased, their peak value increased after bread stimulation with peak time delayed also at 2 hours. Above results demonstrated that the function of islets B cell decreased but not fully deprived. It is concluded that C-peptide and insulin stimulating test, together with OGTT can accurately assess the islets β cell function, and also have important significance in the pathogenesis, classification and staging, prognostic evaluation and monitoring of therapeutic effects in diabetes

  12. Refinement of the wedge bar technique for compression tests at intermediate strain rates

    Directory of Open Access Journals (Sweden)

    Stander M.

    2012-08-01

    Full Text Available A refined development of the wedge-bar technique [1] for compression tests at intermediate strain rates is presented. The concept uses a wedge mechanism to compress small cylindrical specimens at strain rates in the order of 10s−1 to strains of up to 0.3. Co-linear elastic impact principles are used to accelerate the actuation mechanism from rest to test speed in under 300μs while maintaining near uniform strain rates for up to 30 ms, i.e. the transient phase of the test is less than 1% of the total test duration. In particular, a new load frame, load cell and sliding anvil designs are presented and shown to significantly reduce the noise generated during testing. Typical dynamic test results for a selection of metals and polymers are reported and compared with quasistatic and split Hopkinson pressure bar results.

  13. Variation of strain rate sensitivity index of a superplastic aluminum alloy in different testing methods

    Science.gov (United States)

    Majidi, Omid; Jahazi, Mohammad; Bombardier, Nicolas; Samuel, Ehab

    2017-10-01

    The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.

  14. Closure Report for Corrective Action Unit 481: Area 12 T-Tunnel Conditional Release Storage Yard, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    2008-01-01

    Corrective Action Unit (CAU) 481 is identified in the Federal Facility Agreement and Consent Order (FFACO) as Area 12 T-Tunnel Conditional Release Storage Yard. CAU 481 is located in Area 12 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. This CAU consists of one Corrective Action Site (CAS), CAS 12-42-05, Housekeeping Waste. CAU 481 closure activities were conducted by the Defense Threat Reduction Agency from August 2007 through July 2008 according to the FFACO and Revision 3 of the Sectored Clean-up Work Plan for Housekeeping Category Waste Sites. Closure activities included removal and disposal of construction debris and low-level waste. Drained fluids, steel, and lead was recycled as appropriate. Waste generated during closure activities was appropriately managed and disposed.

  15. Performance and Abuse Testing of 5 Year Old Low Rate and Medium Rate Lithium Thionyl Chloride Cells

    Science.gov (United States)

    Frerker, Rick; Zhang, Wenlin; Jeevarajan, Judith; Bragg, Bobby J.

    2001-01-01

    Most cells survived the 3 amp (A) over-discharge at room temperature for 2 hours. The cell that failed was the LTC-114 after high rate discharge of 500 mA similar to the results of the 1 A over-discharge test. Most cells opened during 0.05 Ohm short circuit test without incident but three LTC-111 cells exploded apparently due to a lack of a thermal cutoff switch. The LTC-114 cells exposed to a hard short of 0.05 Ohms recovered but the LTC-114 cells exposed to a soft short of 1 Ohm did not. This is probably due to the activation of a resetable fuse during a hard short. Fresh cells tend to survive exposure to higher temperatures than cells previously discharged at high rate (1 Amp). LTC-111 cells tend to vent at lower temperatures than the all LTC-114 cells and the LTC-115 cells that were previously discharged at rates exceeding 1 Amp.

  16. Tensile strength of concrete under static and intermediate strain rates: Correlated results from different testing methods

    International Nuclear Information System (INIS)

    Wu Shengxing; Chen Xudong; Zhou Jikai

    2012-01-01

    Highlights: ► Tensile strength of concrete increases with increase in strain rate. ► Strain rate sensitivity of tensile strength of concrete depends on test method. ► High stressed volume method can correlate results from various test methods. - Abstract: This paper presents a comparative experiment and analysis of three different methods (direct tension, splitting tension and four-point loading flexural tests) for determination of the tensile strength of concrete under low and intermediate strain rates. In addition, the objective of this investigation is to analyze the suitability of the high stressed volume approach and Weibull effective volume method to the correlation of the results of different tensile tests of concrete. The test results show that the strain rate sensitivity of tensile strength depends on the type of test, splitting tensile strength of concrete is more sensitive to an increase in the strain rate than flexural and direct tensile strength. The high stressed volume method could be used to obtain a tensile strength value of concrete, free from the influence of the characteristics of tests and specimens. However, the Weibull effective volume method is an inadequate method for describing failure of concrete specimens determined by different testing methods.

  17. New method of analyzing well tests in fractured wells using sandface pressure and rate data

    Energy Technology Data Exchange (ETDEWEB)

    Osman, M.; Almehaideb, R.; Abou-Kassem, J. [U.A.E. University, Al-Ain (United Arab Emirates)

    1998-05-01

    Analysis of variable flow rate tests has been of special interest recently because in many cases it is impractical to keep a flow rate constant long enough to perform a drawdown test. Further, in many other drawdown and buildup tests, the early data were influenced by wellbore storage effects, and the duration of these effects could be quite long for low-permeability reservoirs. This paper presents a mathematical model which describes drawdown and buildup tests in hydraulically fractured wells. This new method uses a specialized plot approach to analyze the linear flow data and combines it with the superposition of constant-rate solution method for the analysis of psuedoradial flow data. It does not require prior knowledge of the fracture type (uniform-flux or infinite-conductivity); in fact it predicts the fracture type. This method is useful for the analysis of simultaneously measured downhole pressure and sandface rate data. 12 refs., 11 figs., 3 tabs.

  18. Errors of car wheels rotation rate measurement using roller follower on test benches

    Science.gov (United States)

    Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.

    2018-03-01

    The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.

  19. Interventions to Improve Rate of Diabetes Testing Postpartum in Women With Gestational Diabetes Mellitus.

    Science.gov (United States)

    Hamel, Maureen S; Werner, Erika F

    2017-02-01

    Gestational diabetes mellitus (GDM) is one of the most common medical complications of pregnancy. In the USA, four million women are screened annually for GDM in pregnancy in part to improve pregnancy outcomes but also because diagnosis predicts a high risk of future type 2 diabetes mellitus (T2DM). Therefore, among women with GDM, postpartum care should be focused on T2DM prevention. This review describes the current literature aimed to increase postpartum diabetes testing among women with GDM. Data suggest that proactive patient contact via a health educator, a phone call, or even postal mail is associated with higher rates of postpartum diabetes testing. There may also be utility to changing the timing of postpartum diabetes testing. Despite the widespread knowledge regarding the importance of postpartum testing for women with GDM, testing rates remain low. Alternative testing strategies and large randomized trials addressing postpartum testing are warranted.

  20. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    International Nuclear Information System (INIS)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-01-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 μU/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 μU/ml vs 4.1 - 12.3 μU/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.)

  1. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-10-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 ..mu..U/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 ..mu..U/ml vs 4.1 - 12.3 ..mu..U/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.).

  2. Respirator Filter Efficiency Testing Against Particulate and Biological Aerosols Under Moderate to High Flow Rates

    Science.gov (United States)

    2006-08-01

    flow rate through the test filter. The flow rate was measured using a mass flow meter (Series 4000, TSI, Shoreview, MN). Several modifications were made...operating conditions. This included assessing the effect of non- isokinetic sampling, flow calibrations, and characterization of the challenge...sampling bias on the measured penetrations due to the non- isokinetic sampling downstream. 3.3.2.2 System Characterization. Shakedown tests were

  3. A Bayesian hierarchical model with novel prior specifications for estimating HIV testing rates.

    Science.gov (United States)

    An, Qian; Kang, Jian; Song, Ruiguang; Hall, H Irene

    2016-04-30

    Human immunodeficiency virus (HIV) infection is a severe infectious disease actively spreading globally, and acquired immunodeficiency syndrome (AIDS) is an advanced stage of HIV infection. The HIV testing rate, that is, the probability that an AIDS-free HIV infected person seeks a test for HIV during a particular time interval, given no previous positive test has been obtained prior to the start of the time, is an important parameter for public health. In this paper, we propose a Bayesian hierarchical model with two levels of hierarchy to estimate the HIV testing rate using annual AIDS and AIDS-free HIV diagnoses data. At level one, we model the latent number of HIV infections for each year using a Poisson distribution with the intensity parameter representing the HIV incidence rate. At level two, the annual numbers of AIDS and AIDS-free HIV diagnosed cases and all undiagnosed cases stratified by the HIV infections at different years are modeled using a multinomial distribution with parameters including the HIV testing rate. We propose a new class of priors for the HIV incidence rate and HIV testing rate taking into account the temporal dependence of these parameters to improve the estimation accuracy. We develop an efficient posterior computation algorithm based on the adaptive rejection metropolis sampling technique. We demonstrate our model using simulation studies and the analysis of the national HIV surveillance data in the USA. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Delayed Effects of Remote Limb Ischemic Preconditioning on Maximum Oxygen Consumption, Lactate Release and Pulmonary Function Tests in Athletes and non-Athletes

    Directory of Open Access Journals (Sweden)

    Mahnaz Momeni

    2016-11-01

    Full Text Available Background: Remote Ischemic Preconditioning (RIPC improves exercise performance, and since this phenomenon has two phases, the aim of the current study was to investigate the delayed effects of remote ischemic preconditioning on cardiopulmonary function in athletes and non-athletes. Materials and Methods: 25 male and female students were studied in two main athletes and non-athletes groups. RIPC was induced by using 3 cycles of alternative 5 minutes ischemia and 5 minutes reperfusion at arms of participants. Cardiopulmonary tests were measured before, after and 24 hours after inducing remote ischemic preconditioning. Maximum oxygen consumption (VO2max estimated by using queen steps test. Results: Analysis of data demonstrated that delayed RIPC in non-athletes group caused significant improvement in Forced Expiratory Volume in one second (FEV1 and Maximum Voluntary Ventilation (MVV and noticeable improvement in some other parameters of pulmonary function tests. Moreover, it decreased systolic blood pressure and heart rate and decreased lactate release in both groups especially athletes group but it had no significant effect on VO2max of both groups. Conclusion: Delayed RIPC improves cardiovascular function of athletes and pulmonary function of non-athletes subjects. Thus, it can be considered as a good replacement for doping to improve sports performance of subjects in sports tournaments.

  5. Testing linear growth rate formulas of non-scale endogenous growth models

    NARCIS (Netherlands)

    Ziesemer, Thomas

    2017-01-01

    Endogenous growth theory has produced formulas for steady-state growth rates of income per capita which are linear in the growth rate of the population. Depending on the details of the models, slopes and intercepts are positive, zero or negative. Empirical tests have taken over the assumption of

  6. Results of a pilot scale melter test to attain higher production rates

    International Nuclear Information System (INIS)

    Elliott, M.L.; Perez, J.M. Jr.; Chapman, C.C.

    1991-01-01

    A pilot-scale melter test was completed as part of the effort to enhance glass production rates. The experiment was designed to evaluate the effects of bulk glass temperature and feed oxide loading. The maximum glass production rate obtained, 86 kg/hr-m 2 , was over 200% better than the previous record for the melter used

  7. Calorimeter measures high nuclear heating rates and their gradients across a reactor test hole

    Science.gov (United States)

    Burwell, D.; Coombe, J. R.; Mc Bride, J.

    1970-01-01

    Pedestal-type calorimeter measures gamma-ray heating rates from 0.5 to 7.0 watts per gram of aluminum. Nuclear heating rate is a function of cylinder temperature change, measured by four chromel-alumel thermocouples attached to the calorimeter, and known thermoconductivity of the tested material.

  8. Technical principles underlying limit values for release of substances for the percolation test TS3: comparison DE and NL

    Energy Technology Data Exchange (ETDEWEB)

    Van Zomeren, A.; Dijkstra, J.J. [ECN Environment and Energy Engineering, Petten (Netherlands); Susset, B. [Consulting Office SiWaP (Germany)

    2013-10-15

    Within CEN TC 351 WG 1, standardized, horizontal test methods are developed to assess the release (leaching) of dangerous substances from construction as defined in ER3 of the CPD. For granular materials TS 3, a horizontal up-flow percolation test, was further developed by CEN TC 351 WG1 and will enter the validation phase in 2013. In CEN TC 351 WG1, there are still discussions regarding the sample preparation and some test conditions. Currently, two options for sample preparation and test conditions are specified. Controversy between DE and NL regarding sample preparation and test conditions and the need for two separate options in the TS 3 percolation test are possibly for a part caused by different approaches for risk assessment in the Netherlands and in Germany and the resulting regulatory concepts. One important reason for this is, that in soil and groundwater regulations the test method and the impact assessment method are systematically linked together but the impact assessment methods and lab methods in both countries are different. The discussions in CEN TC 351 WG 1 show that there is a need to have a better mutual understanding of the relation between test method and impact assessment on the one hand and a clear overview of differences in impact assessment approaches of each country on the other hand. The aim of this project is to explain and compare the assumptions, boundary conditions and conventions of the impact assessment approach that are implemented in the upcoming German Recycling Degree and in the Soil Quality Degree of the Netherlands. Ultimately, a better understanding of the impact assessment approaches provides a basis for further discussion in WG1 to agree on only one option for the percolation test conditions. The following report is prepared by the contractors of Germany and Netherlands together to compare the two country-specific concepts. This report summarizes and explains the presentation given on the 25th of April at TC 351 WG1 in

  9. Random breath testing in Queensland and Western Australia: examination of how the random breath testing rate influences alcohol related traffic crash rates.

    Science.gov (United States)

    Ferris, Jason; Mazerolle, Lorraine; King, Mark; Bates, Lyndel; Bennett, Sarah; Devaney, Madonna

    2013-11-01

    In this paper we explore the relationship between monthly random breath testing (RBT) rates (per 1000 licensed drivers) and alcohol-related traffic crash (ARTC) rates over time, across two Australian states: Queensland and Western Australia. We analyse the RBT, ARTC and licensed driver rates across 12 years; however, due to administrative restrictions, we model ARTC rates against RBT rates for the period July 2004 to June 2009. The Queensland data reveals that the monthly ARTC rate is almost flat over the five year period. Based on the results of the analysis, an average of 5.5 ARTCs per 100,000 licensed drivers are observed across the study period. For the same period, the monthly rate of RBTs per 1000 licensed drivers is observed to be decreasing across the study with the results of the analysis revealing no significant variations in the data. The comparison between Western Australia and Queensland shows that Queensland's ARTC monthly percent change (MPC) is 0.014 compared to the MPC of 0.47 for Western Australia. While Queensland maintains a relatively flat ARTC rate, the ARTC rate in Western Australia is increasing. Our analysis reveals an inverse relationship between ARTC RBT rates, that for every 10% increase in the percentage of RBTs to licensed driver there is a 0.15 decrease in the rate of ARTCs per 100,000 licenced drivers. Moreover, in Western Australia, if the 2011 ratio of 1:2 (RBTs to annual number of licensed drivers) were to double to a ratio of 1:1, we estimate the number of monthly ARTCs would reduce by approximately 15. Based on these findings we believe that as the number of RBTs conducted increases the number of drivers willing to risk being detected for drinking driving decreases, because the perceived risk of being detected is considered greater. This is turn results in the number of ARTCs diminishing. The results of this study provide an important evidence base for policy decisions for RBT operations. Copyright © 2013 Elsevier Ltd. All

  10. Nano-encapsulation of olive leaf phenolic compounds through WPC-pectin complexes and evaluating their release rate.

    Science.gov (United States)

    Mohammadi, Adeleh; Jafari, Seid Mahdi; Assadpour, Elham; Faridi Esfanjani, Afshin

    2016-01-01

    In this study, W/O micro-emulsions as primary emulsions and a complex of whey protein concentrate (WPC) and pectin in the external aqueous phase were used to produce W/O/W emulsions. Average droplet size of primary W/O emulsion and multiple emulsions stabilized by WPC or WPC-pectin after one day of production was 6.16, 675.7 and 1443 nm, respectively, which achieved to 22.97, 347.7 and, 1992.4 nm after 20 days storage without any sedimentation. The encapsulation efficiency of phenolic compounds for stabilized W/O/W emulsions with WPC and WPC-pectin were 93.34% and 96.64%, respectively, which was decreased to 72.73% and 88.81% at 20th storage day. The lowest release of phenolics observed in multiple emulsions of WPC-pectin. These results suggest that nano-encapsulation of olive leaf extract within inner aqueous phase of W/O/W emulsions was successful, and there could be a high potential for the application of olive leaf extract in fortification of food products. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Morphology of Gas Release in Physical Simulants

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Burns, Carolyn A.; Crawford, Amanda D.; Hylden, Laura R.; Bryan, Samuel A.; MacFarlan, Paul J.; Gauglitz, Phillip A.

    2014-07-03

    This report documents testing activities conducted as part of the Deep Sludge Gas Release Event Project (DSGREP). The testing described in this report focused on evaluating the potential retention and release mechanisms of hydrogen bubbles in underground radioactive waste storage tanks at Hanford. The goal of the testing was to evaluate the rate, extent, and morphology of gas release events in simulant materials. Previous, undocumented scoping tests have evidenced dramatically different gas release behavior from simulants with similar physical properties. Specifically, previous gas release tests have evaluated the extent of release of 30 Pa kaolin and 30 Pa bentonite clay slurries. While both materials are clays and both have equivalent material shear strength using a shear vane, it was found that upon stirring, gas was released immediately and completely from bentonite clay slurry while little if any gas was released from the kaolin slurry. The motivation for the current work is to replicate these tests in a controlled quality test environment and to evaluate the release behavior for another simulant used in DSGREP testing. Three simulant materials were evaluated: 1) a 30 Pa kaolin clay slurry, 2) a 30 Pa bentonite clay slurry, and 3) Rayleigh-Taylor (RT) Simulant (a simulant designed to support DSGREP RT instability testing. Entrained gas was generated in these simulant materials using two methods: 1) application of vacuum over about a 1-minute period to nucleate dissolved gas within the simulant and 2) addition of hydrogen peroxide to generate gas by peroxide decomposition in the simulants over about a 16-hour period. Bubble release was effected by vibrating the test material using an external vibrating table. When testing with hydrogen peroxide, gas release was also accomplished by stirring of the simulant.

  12. Controlling the Release of Indomethacin from Glass Solutions Layered with a Rate Controlling Membrane Using Fluid-Bed Processing. Part 1: Surface and Cross-Sectional Chemical Analysis.

    Science.gov (United States)

    Dereymaker, Aswin; Scurr, David J; Steer, Elisabeth D; Roberts, Clive J; Van den Mooter, Guy

    2017-04-03

    Fluid bed coating has been shown to be a suitable manufacturing technique to formulate poorly soluble drugs in glass solutions. Layering inert carriers with a drug-polymer mixture enables these beads to be immediately filled into capsules, thus avoiding additional, potentially destabilizing, downstream processing. In this study, fluid bed coating is proposed for the production of controlled release dosage forms of glass solutions by applying a second, rate controlling membrane on top of the glass solution. Adding a second coating layer adds to the physical and chemical complexity of the drug delivery system, so a thorough understanding of the physical structure and phase behavior of the different coating layers is needed. This study aimed to investigate the surface and cross-sectional characteristics (employing scanning electron microscopy (SEM) and time of flight secondary ion mass spectrometry (ToF-SIMS)) of an indomethacin-polyvinylpyrrolidone (PVP) glass solution, top-coated with a release rate controlling membrane consisting of either ethyl cellulose or Eudragit RL. The implications of the addition of a pore former (PVP) and the coating medium (ethanol or water) were also considered. In addition, polymer miscibility and the phase analysis of the underlying glass solution were investigated. Significant differences in surface and cross-sectional topography of the different rate controlling membranes or the way they are applied (solution vs dispersion) were observed. These observations can be linked to the polymer miscibility differences. The presence of PVP was observed in all rate controlling membranes, even if it is not part of the coating solution. This could be attributed to residual powder presence in the coating chamber. The distribution of PVP among the sample surfaces depends on the concentration and the rate controlling polymer used. Differences can again be linked to polymer miscibility. Finally, it was shown that the underlying glass solution layer

  13. Relative User Ratings of MMPI-2 Computer-Based Test Interpretations

    Science.gov (United States)

    Williams, John E.; Weed, Nathan C.

    2004-01-01

    There are eight commercially available computer-based test interpretations (CBTIs) for the Minnesota Multiphasic Personality Inventory-2 (MMPI-2), of which few have been empirically evaluated. Prospective users of these programs have little scientific data to guide choice of a program. This study compared ratings of these eight CBTIs. Test users…

  14. Taking the Test Taker's Perspective: Response Process and Test Motivation in Multidimensional Forced-Choice Versus Rating Scale Instruments.

    Science.gov (United States)

    Sass, Rachelle; Frick, Susanne; Reips, Ulf-Dietrich; Wetzel, Eunike

    2018-03-01

    The multidimensional forced-choice (MFC) format has been proposed as an alternative to the rating scale (RS) response format. However, it is unclear how changing the response format may affect the response process and test motivation of participants. In Study 1, we investigated the MFC response process using the think-aloud technique. In Study 2, we compared test motivation between the RS format and different versions of the MFC format (presenting 2, 3, 4, and 5 items simultaneously). The response process to MFC item blocks was similar to the RS response process but involved an additional step of weighing the items within a block against each other. The RS and MFC response format groups did not differ in their test motivation. Thus, from the test taker's perspective, the MFC format is somewhat more demanding to respond to, but this does not appear to decrease test motivation.

  15. Interaction of initial litter quality and thinning intensity on litter decomposition rate, nitrogen accumulation and release in a pine plantation

    Science.gov (United States)

    Xiao Chen; Deborah Page-Dumroese; Ruiheng Lv; Weiwei Wang; Guolei Li; Yong. Liu

    2014-01-01

    Thinning alters litter quality and microclimate under forests. Both of these two changes after thinning induce alterations of litter decomposition rates and nutrient cycling. However, a possible interaction between these two changes remains unclear. We placed two types of litter (LN, low N concentration litter; HN, high N concentration litter) in a Chinese pine (Pinus...

  16. Estimates of external dose-rate conversion factors and internal dose conversion factors for selected radionuclides released from fusion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Homma, Toshimitsu; Togawa, Orihiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-11-01

    This report provides a tabulation of both external dose-rate conversion factors and internal dose conversion factors using radioactive decay data in the updated Evaluated Nuclear Structure Data File (ENSDF) for selected 26 radionuclides and all their daughter radionuclides of potential importance in safety assessments of fusion facilities. The external dose-rate conversion factors for 21 target organs are tabulated for three exposure modes that are immersion in contaminated air, irradiation at a height of 1 m above a contaminated ground surface and immersion contaminated water. For internal exposure, committed dose equivalents, based on the methodology of ICRP Publication 30, in the same target organs per intake of unit activity are given for the inhalation and ingestion exposure pathways. The data presented here is intended to be generally used for safety assessments of fusion reactors. Comparisons of external effective dose-rate conversion factors and committed effective dose equivalents are made with the previous data from the independent data bases to provide quality assurance on our calculated results. There is generally good agreement among data from the independent data bases. The differences in the values of both effective dose-rate and dose conversion factors appeared are primarily due to differences in calculational methodology, the use of different radioactive decay data, and compilation errors. (author)

  17. Variation in effective pollination rates in relation to the spatial and temporal distribution of pollen release in rejuvenated perennial ryegrass

    NARCIS (Netherlands)

    Treuren, van R.; Goossens, P.J.; Sevcikova, M.

    2006-01-01

    Genebank accessions stored as seed populations require periodic rejuvenation in order to maintain sufficient numbers of viable seeds. During rejuvenation the genetic composition of accessions may be altered for a variety of reasons, of which variation in pollination rates between plants is the least

  18. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    Science.gov (United States)

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  19. Differential effects of 18- and 24-Gy cranial irradiation on growth rate and growth hormone release in children with prolonged survival after acute lymphocytic leukemia

    International Nuclear Information System (INIS)

    Cicognani, A.; Cacciari, E.; Vecchi, V.; Cau, M.; Balsamo, A.; Pirazzoli, P.; Tosi, M.T.; Rosito, P.; Paolucci, G.

    1988-01-01

    To evaluate the effects of two different doses of cranial irradiation on growth and growth hormone (GH) release, we studied 61 children with acute lymphocytic leukemia who had survived at least five years in continuous complete remission. Forty-three children received 24 Gy (group 1) and 18 children received 18 Gy (group 2). Height was evaluated at diagnosis, at the end of treatment, and 6, 12, and 24 months later. Growth hormone release was evaluated by arginine and levodopa tests after the end of treatment. After diagnosis, the height SD score decreased significantly in both groups; two years after the end of treatment, only group 1 showed an SD score for height that was still significantly lower than at diagnosis. Group 1 showed impaired GH responses to the tests and, compared with controls, group 1 in fact included a percentage of subjects with a normal response to levodopa (ie, greater than 8 micrograms/L) that was significantly lower (56.4% vs 83.3%) and a percentage of nonresponders to both tests that was significantly higher (21.6% vs 0%). These data indicate that only patients treated with lower cranial irradiation dosage (18 Gy) had complete growth recovery and normal GH responses to pharmacologic tests

  20. Pre-steady-state kinetic analysis of 1-deoxy-D-xylulose-5-phosphate reductoisomerase from Mycobacterium tuberculosis reveals partially rate-limiting product release by parallel pathways.

    Science.gov (United States)

    Liu, Juan; Murkin, Andrew S

    2012-07-03

    As part of the non-mevalonate pathway for the biosynthesis of the isoprenoid precursor isopentenyl pyrophosphate, 1-deoxy-D-xylulose-5-phosphate (DXP) reductoisomerase (DXR) catalyzes the conversion of DXP into 2-C-methyl-D-erythritol 4-phosphate (MEP) by consecutive isomerization and NADPH-dependent reduction reactions. Because this pathway is essential to many infectious organisms but is absent in humans, DXR is a target for drug discovery. In an attempt to characterize its kinetic mechanism and identify rate-limiting steps, we present the first complete transient kinetic investigation of DXR. Stopped-flow fluorescence measurements with Mycobacterium tuberculosis DXR (MtDXR) revealed that NADPH and MEP bind to the free enzyme and that the two bind together to generate a nonproductive ternary complex. Unlike the Escherichia coli orthologue, MtDXR exhibited a burst in the oxidation of NADPH during pre-steady-state reactions, indicating a partially rate-limiting step follows chemistry. By monitoring NADPH fluorescence during these experiments, the transient generation of MtDXR·NADPH·MEP was observed. Global kinetic analysis supports a model involving random substrate binding and ordered release of NADP(+) followed by MEP. The partially rate-limiting release of MEP occurs via two pathways--directly from the binary complex and indirectly via the MtDXR·NADPH·MEP complex--the partitioning being dependent on NADPH concentration. Previous mechanistic studies, including kinetic isotope effects and product inhibition, are discussed in light of this kinetic mechanism.

  1. Proposal of the concept of selection of accidents that release large amounts of radioactive substances in the high temperature engineering test reactor

    International Nuclear Information System (INIS)

    Ono, Masato; Honda, Yuki; Takada, Shoji; Sawa, Kazuhiro

    2015-01-01

    In Position, construction and equipment of testing and research reactor to be subjected to the use standards for rules Article 53 (prevention of expansion of the accident to release a large amount of radioactive material) generation the frequency is a lower accident than design basis accident, when what is likely to release a large amount of radioactive material or radiation from the facility has occurred, and take the necessary measures in order to prevent the spread of the accident. There is provided a lower accident than frequency design basis accidents, for those that may release a large amount of radioactive material or radiation. (author)

  2. [The maximum heart rate in the exercise test: the 220-age formula or Sheffield's table?].

    Science.gov (United States)

    Mesquita, A; Trabulo, M; Mendes, M; Viana, J F; Seabra-Gomes, R

    1996-02-01

    To determine in the maximum cardiac rate in exercise test of apparently healthy individuals may be more properly estimated through 220-age formula (Astrand) or the Sheffield table. Retrospective analysis of clinical history and exercises test of apparently healthy individuals submitted to cardiac check-up. Sequential sampling of 170 healthy individuals submitted to cardiac check-up between April 1988 and September 1992. Comparison of maximum cardiac rate of individuals studied by the protocols of Bruce and modified Bruce, in interrupted exercise test by fatigue, and with the estimated values by the formulae: 220-age versus Sheffield table. The maximum cardiac heart rate is similar with both protocols. This parameter in normal individuals is better predicted by the 220-age formula. The theoretic maximum cardiac heart rate determined by 220-age formula should be recommended for a healthy, and for this reason the Sheffield table has been excluded from our clinical practice.

  3. Bit error rate testing of fiber optic data links for MMIC-based phased array antennas

    Science.gov (United States)

    Shalkhauser, K. A.; Kunath, R. R.; Daryoush, A. S.

    1990-01-01

    The measured bit-error-rate (BER) performance of a fiber optic data link to be used in satellite communications systems is presented and discussed. In the testing, the link was measured for its ability to carry high burst rate, serial-minimum shift keyed (SMSK) digital data similar to those used in actual space communications systems. The fiber optic data link, as part of a dual-segment injection-locked RF fiber optic link system, offers a means to distribute these signals to the many radiating elements of a phased array antenna. Test procedures, experimental arrangements, and test results are presented.

  4. 105-KE Basin isolation barrier leak rate test analytical development. Revision 1

    International Nuclear Information System (INIS)

    Irwin, J.J.

    1995-01-01

    This document provides an analytical development in support of the proposed leak rate test of the 105-KE Basin. The analytical basis upon which the K-basin leak test results will be used to determine the basin leakage rates is developed in this report. The leakage of the K-Basin isolation barriers under postulated accident conditions will be determined from the test results. There are two fundamental flow regimes that may exist in the postulated K-Basin leakage: viscous laminar and turbulent flow. An analytical development is presented for each flow regime. The basic geometry and nomenclature of the postulated leak paths are denoted

  5. Standard Test Method for Determining Thermal Neutron Reaction Rates and Thermal Neutron Fluence Rates by Radioactivation Techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 The purpose of this test method is to define a general procedure for determining an unknown thermal-neutron fluence rate by neutron activation techniques. It is not practicable to describe completely a technique applicable to the large number of experimental situations that require the measurement of a thermal-neutron fluence rate. Therefore, this method is presented so that the user may adapt to his particular situation the fundamental procedures of the following techniques. 1.1.1 Radiometric counting technique using pure cobalt, pure gold, pure indium, cobalt-aluminum, alloy, gold-aluminum alloy, or indium-aluminum alloy. 1.1.2 Standard comparison technique using pure gold, or gold-aluminum alloy, and 1.1.3 Secondary standard comparison techniques using pure indium, indium-aluminum alloy, pure dysprosium, or dysprosium-aluminum alloy. 1.2 The techniques presented are limited to measurements at room temperatures. However, special problems when making thermal-neutron fluence rate measurements in high-...

  6. Flow rate and source reservoir identification from airborne chemical sampling of the uncontrolled Elgin platform gas release

    Science.gov (United States)

    Lee, James D.; Mobbs, Stephen D.; Wellpott, Axel; Allen, Grant; Bauguitte, Stephane J.-B.; Burton, Ralph R.; Camilli, Richard; Coe, Hugh; Fisher, Rebecca E.; France, James L.; Gallagher, Martin; Hopkins, James R.; Lanoiselle, Mathias; Lewis, Alastair C.; Lowry, David; Nisbet, Euan G.; Purvis, Ruth M.; O'Shea, Sebastian; Pyle, John A.; Ryerson, Thomas B.

    2018-03-01

    An uncontrolled gas leak from 25 March to 16 May 2012 led to evacuation of the Total Elgin wellhead and neighbouring drilling and production platforms in the UK North Sea. Initially the atmospheric flow rate of leaking gas and condensate was very poorly known, hampering environmental assessment and well control efforts. Six flights by the UK FAAM chemically instrumented BAe-146 research aircraft were used to quantify the flow rate. The flow rate was calculated by assuming the plume may be modelled by a Gaussian distribution with two different solution methods: Gaussian fitting in the vertical and fitting with a fully mixed layer. When both solution methods were used they compared within 6 % of each other, which was within combined errors. Data from the first flight on 30 March 2012 showed the flow rate to be 1.3 ± 0.2 kg CH4 s-1, decreasing to less than half that by the second flight on 17 April 2012. δ13CCH4 in the gas was found to be -43 ‰, implying that the gas source was unlikely to be from the main high pressure, high temperature Elgin gas field at 5.5 km depth, but more probably from the overlying Hod Formation at 4.2 km depth. This was deemed to be smaller and more manageable than the high pressure Elgin field and hence the response strategy was considerably simpler. The first flight was conducted within 5 days of the blowout and allowed a flow rate estimate within 48 h of sampling, with δ13CCH4 characterization soon thereafter, demonstrating the potential for a rapid-response capability that is widely applicable to future atmospheric emissions of environmental concern. Knowledge of the Elgin flow rate helped inform subsequent decision making. This study shows that leak assessment using appropriately designed airborne plume sampling strategies is well suited for circumstances where direct access is difficult or potentially dangerous. Measurements such as this also permit unbiased regulatory assessment of potential impact, independent of the emitting

  7. Drought stress release increased growth rate but did not affect levels of storage carbohydrates in Scots pine trees

    Science.gov (United States)

    Schönbeck, Leonie; Gessler, Arthur; Rigling, Andreas; Schaub, Marcus; Li, Mai-He

    2017-04-01

    For trees, energy storage in the form of non-structural carbohydrates (NSCs) plays an important role for survival and growth, especially during stress events such as drought. It is hypothesized, that tree individuals that experience long-term drought stress use up larger amounts of NSCs than trees that do not experience drought. Consequently, such drought-induced depletion might lead to a decrease in tree vigor and carbon starvation, a mechanism that is subject of intensive debates in recent literature. Hence, if carbon starvation is occurring during drought, drought stress release should again increase NSC concentrations. A long-term (13 years) irrigation experiment is being conducted in the Pfyn forest, the largest Pinus sylvestris dominated forest in Switzerland, located in the dry inner-Alpine Swiss Rhone valley (average precipitation 600 mm/year, with frequent dry spells). Water addition ( 600 mm/year) is executed every year during the growing season between April and October. Tree height, stem diameter and crown transparency are being measured since 2003. In February, July and October 2015, roots, stem sapwood and needles were harvested from 30 irrigated and 30 control trees and 5 different crown transparency classes. Shoot length, needle morphology, soluble sugars, starch concentrations, needle δ13C and δ15N were measured. Shoot and stem growth were higher in irrigated trees than in control trees. Growth decreased with increasing crown transparency in both treatments. Only in July, needle starch levels were higher in irrigated trees than in control trees but there was no treatment effect for wood and root starch concentrations. Tissue starch and sugar levels were negatively correlated with crown transparency, particularly in the roots (preduced NSC is related to reduced tree vigor under drought.

  8. Testing for long-range dependence in the Brazilian term structure of interest rates

    International Nuclear Information System (INIS)

    Cajueiro, Daniel O.; Tabak, Benjamin M.

    2009-01-01

    This paper presents empirical evidence of fractional dynamics in interest rates for different maturities for Brazil. A variation of a newly developed test for long-range dependence, the V/S statistic, with a post-blackening bootstrap is employed. Results suggest that Brazilian interest rates possess strong long-range dependence in volatility, even when considering the structural break in 1999. These findings imply that the development of policy models that give rise to long-range dependence in interest rates' volatility could be very useful. The long-short-term interest rates spread has strong long-range dependence, which suggests that traditional tests of expectation hypothesis of the term structure of interest rates may be misspecified.

  9. Simplified method of ''push-pull'' test data analysis for determining in situ reaction rate coefficients

    International Nuclear Information System (INIS)

    Haggerty, R.; Schroth, M.H.; Istok, J.D.

    1998-01-01

    The single-well, ''''push-pull'''' test method is useful for obtaining information on a wide variety of aquifer physical, chemical, and microbiological characteristics. A push-pull test consists of the pulse-type injection of a prepared test solution into a single monitoring well followed by the extraction of the test solution/ground water mixture from the same well. The test solution contains a conservative tracer and one or more reactants selected to investigate a particular process. During the extraction phase, the concentrations of tracer, reactants, and possible reaction products are measured to obtain breakthrough curves for all solutes. This paper presents a simplified method of data analysis that can be used to estimate a first-order reaction rate coefficient from these breakthrough curves. Rate coefficients are obtained by fitting a regression line to a plot of normalized concentrations versus elapsed time, requiring no knowledge of aquifer porosity, dispersivity, or hydraulic conductivity. A semi-analytical solution to the advective-dispersion equation is derived and used in a sensitivity analysis to evaluate the ability of the simplified method to estimate reaction rate coefficients in simulated push-pull tests in a homogeneous, confined aquifer with a fully-penetrating injection/extraction well and varying porosity, dispersivity, test duration, and reaction rate. A numerical flow and transport code (SUTRA) is used to evaluate the ability of the simplified method to estimate reaction rate coefficients in simulated push-pull tests in a heterogeneous, unconfined aquifer with a partially penetrating well. In all cases the simplified method provides accurate estimates of reaction rate coefficients; estimation errors ranged from 0.1 to 8.9% with most errors less than 5%

  10. Corrective Action Investigation Plan for Corrective Action Unit 554: Area 23 Release Site, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Boehlecke, Robert F.

    2004-01-01

    This Corrective Action Investigation Plan (CAIP) contains project-specific information for conducting site investigation activities at Corrective Action Unit (CAU) 554: Area 23 Release Site, Nevada Test Site, Nevada. Information presented in this CAIP includes facility descriptions, environmental sample collection objectives, and criteria for the selection and evaluation of environmental samples. Corrective Action Unit 554 is located in Area 23 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 554 is comprised of one Corrective Action Site (CAS), which is: 23-02-08, USTs 23-115-1, 2, 3/Spill 530-90-002. This site consists of soil contamination resulting from a fuel release from underground storage tanks (USTs). Corrective Action Site 23-02-08 is being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation prior to evaluating corrective action alternatives and selecting the appropriate corrective action for this CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document for CAU 554. Corrective Action Site 23-02-08 will be investigated based on the data quality objectives (DQOs) developed on July 15, 2004, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office; and contractor personnel. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 554. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to CAS 23-02-08. The scope of the corrective action investigation

  11. Split-Hopkinson Pressure Bar: an experimental technique for high strain rate tests

    International Nuclear Information System (INIS)

    Sharma, S.; Chavan, V.M.; Agrawal, R.G.; Patel, R.J.; Kapoor, R.; Chakravartty, J.K.

    2011-06-01

    Mechanical properties of materials are, in general, strain rate dependent, i.e. they respond differently at quasi-static and higher strain rate condition. The Split-Hopkinson Pressure Bar (SHPB), also referred to as Kolsky bar is a commonly used setup for high strain rate testing. SHPB is suitable for high strain rate test in strain rate range of 10 2 to 10 4 s -1 . These high strain rate data are required for safety and structural integrity assessment of structures subjected to dynamic loading. As high strain rate data are not easily available in open literature need was felt for setting up such high strain rate testing machine. SHPB at BARC was designed and set-up inhouse jointly by Refuelling Technology Division and Mechanical Metallurgy Division, at Hall no. 3, BARC. A number of conceptual designs for SHPB were thought of and the optimized design was worked out. The challenges of precision tolerance, straightness in bars and design and proper functioning of pneumatic gun were met. This setup has been used extensively to study the high strain rate material behavior. This report introduces the SHPB in general and the setup at BARC in particular. The history of development of SHPB, the basic formulations of one dimensional wave propagation, the relations between the wave velocity, particle velocity and elastic strain in a one dimensional bar, and the equations used to obtain the final stress vs. strain curves are described. The calibration of the present setup, the pre-test calculations and the posttest analysis of data are described. Finally some of the experimental results on different materials such as Cu, SS305, SA516 and Zr, at room temperature and elevated temperatures are presented. (author)

  12. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    Science.gov (United States)

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  13. Kepler Planet Detection Metrics: Pixel-Level Transit Injection Tests of Pipeline Detection Efficiency for Data Release 25

    Science.gov (United States)

    Christiansen, Jessie L.

    2017-01-01

    This document describes the results of the fourth pixel-level transit injection experiment, which was designed to measure the detection efficiency of both the Kepler pipeline (Jenkins 2002, 2010; Jenkins et al. 2017) and the Robovetter (Coughlin 2017). Previous transit injection experiments are described in Christiansen et al. (2013, 2015a,b, 2016).In order to calculate planet occurrence rates using a given Kepler planet catalogue, produced with a given version of the Kepler pipeline, we need to know the detection efficiency of that pipeline. This can be empirically determined by injecting a suite of simulated transit signals into the Kepler data, processing the data through the pipeline, and examining the distribution of successfully recovered transits. This document describes the results for the pixel-level transit injection experiment performed to accompany the final Q1-Q17 Data Release 25 (DR25) catalogue (Thompson et al. 2017)of the Kepler Objects of Interest. The catalogue was generated using the SOC pipeline version 9.3 and the DR25 Robovetter acting on the uniformly processed Q1-Q17 DR25 light curves (Thompson et al. 2016a) and assuming the Q1-Q17 DR25 Kepler stellar properties (Mathur et al. 2017).

  14. COMBUSTION HEAT RELEASE RATE ANALYSIS OF C.I. ENGINE WITH SECONDARY CO-INJECTION OF DEE-H2O SOLUTION - A VIBRATIONAL APPROACH

    Directory of Open Access Journals (Sweden)

    Y. V. V. SATYANARAYANA MURTHY

    2015-08-01

    Full Text Available This paper discusses the combustion propensity of single cylinder direct injection engine fueled with palm kernel methyl ester (PKME, which is non- edible oil and a secondary co-injection of saturated Diethyl ether (DEE with water. DEE along with water is fumigated through a high pressure nozzle fitted to the inlet manifold of the engine and the flow rate of the secondary injection was electronically controlled. DEE is known to improve the cold starting problem in engines when used in straight diesel fuel. However, its application in emulsion form is little known. Experimental results show that for 5% DEE- H2O solution injection, occurrence of maximum net heat release rate is delayed due to controlled premixed combustion, which normally helped in better torque conversion when the piston is in accelerated mode. Vibration measurements in the frequency range of 900Hz to 1300Hz revealed that a new mode of combustion has taken place with different excitation frequencies.

  15. Evaluation of susceptibility of high strength steels to delayed fracture by using cyclic corrosion test and slow strain rate test

    International Nuclear Information System (INIS)

    Li Songjie; Zhang Zuogui; Akiyama, Eiji; Tsuzaki, Kaneaki; Zhang Boping

    2010-01-01

    To evaluate susceptibilities of high strength steels to delayed fracture, slow strain rate tests (SSRT) of notched bar specimens of AISI 4135 with tensile strengths of 1300 and 1500 MPa and boron-bearing steel with 1300 MPa have been performed after cyclic corrosion test (CCT). During SSRT the humidity around the specimen was kept high to keep absorbed diffusible hydrogen. The fracture stresses of AISI 4135 steels decreased with increment of diffusible hydrogen content which increased with CCT cycles. Their delayed fracture susceptibilities could be successfully evaluated in consideration of both influence of hydrogen content on mechanical property and hydrogen entry.

  16. Evaluation of susceptibility of high strength steels to delayed fracture by using cyclic corrosion test and slow strain rate test

    Energy Technology Data Exchange (ETDEWEB)

    Li Songjie [School of Materials Science and Engineering, University of Science and Technology Beijing, No. 30 Xueyuan Road, Hidian Zone, Beijing 100083 (China); Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Zhang Zuogui [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Akiyama, Eiji [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan)], E-mail: AKIYAMA.Eiji@nims.go.jp; Tsuzaki, Kaneaki [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Zhang Boping [School of Materials Science and Engineering, University of Science and Technology Beijing, No. 30 Xueyuan Road, Hidian Zone, Beijing 100083 (China)

    2010-05-15

    To evaluate susceptibilities of high strength steels to delayed fracture, slow strain rate tests (SSRT) of notched bar specimens of AISI 4135 with tensile strengths of 1300 and 1500 MPa and boron-bearing steel with 1300 MPa have been performed after cyclic corrosion test (CCT). During SSRT the humidity around the specimen was kept high to keep absorbed diffusible hydrogen. The fracture stresses of AISI 4135 steels decreased with increment of diffusible hydrogen content which increased with CCT cycles. Their delayed fracture susceptibilities could be successfully evaluated in consideration of both influence of hydrogen content on mechanical property and hydrogen entry.

  17. Silica-Based and Borate-Based, Titania-Containing Bioactive Coatings Characterization: Critical Strain Energy Release Rate, Residual Stresses, Hardness, and Thermal Expansion

    Directory of Open Access Journals (Sweden)

    Omar Rodriguez

    2016-12-01

    Full Text Available Silica-based and borate-based glass series, with increasing amounts of TiO2 incorporated, are characterized in terms of their mechanical properties relevant to their use as metallic coating materials. It is observed that borate-based glasses exhibit CTE (Coefficient of Thermal Expansion closer to the substrate’s (Ti6Al4V CTE, translating into higher mode I critical strain energy release rates of glasses and compressive residual stresses and strains at the coating/substrate interface, outperforming the silica-based glasses counterparts. An increase in the content of TiO2 in the glasses results in an increase in the mode I critical strain energy release rate for both the bulk glass and for the coating/substrate system, proving that the addition of TiO2 to the glass structure enhances its toughness, while decreasing its bulk hardness. Borate-based glass BRT3, with 15 mol % TiO2 incorporated, exhibits superior properties overall compared to the other proposed glasses in this work, as well as 45S5 Bioglass® and Pyrex.

  18. The radiological situation at the atolls of Mururoa and Fangataufa. Technical report. V. 4. Releases to the biosphere of radionuclides from underground nuclear weapon tests at the atolls

    International Nuclear Information System (INIS)

    1998-08-01

    This report is Volume 4 in the series of 6 volumes of the Technical Report on the radiological situation at the atolls of Mururoa and the Fangataufa. It is the second of the three volumes dealing with the evaluation of the long term radiological situation as a consequence of radionuclide migration from underground sources, which is the responsibility of Task Group B. This volume is based on the activities of Working Group 4 and uses, as its primary input on radionuclide inventories the report of Working Group 3, which is Vol. 3 in this series of Technical Report. Nuclear testing in the atmosphere, outer space and under open ocean was prohibited by the Limited Test Ban Treaty of 5 August 1963 and signed by UK, USA and USSR. France ceased atmospheric testing in September 1974. Isolation from the biosphere in geological formations, or containment in geological formations, became the preferred alternative. The explosion of 137 underground nuclear devices in Mururoa and Fangataufa over the testing period 1975-1996, together with 10 safety trials and the burial of radioactively contaminated material gathered from the atoll surfaces, has resulted in a substantial accumulation of radionuclides in the rock beneath the two atolls. Assessment of the rate at which these radionuclides move from the cavities to the environment accessible to humans, or biosphere and the total radionuclide release to the biosphere over time is the central effort of this Study. The rock mass within which the radionuclides are initially deposited, and which serves to contain or delay release of the radionuclides, will be referred to as the geosphere to distinguish it from the biosphere, where the radionuclides would be accessible either directly or through the food chain to the living environment. This assessment of geosphere transport has been divided into the following four interrelated tasks: (a) Geological Pathways; (b) Hydrological Modelling; (c) Solution Source Term; and (d) Geosphere

  19. Changes in cortisol release and heart rate variability in sport horses during long-distance road transport.

    Science.gov (United States)

    Schmidt, A; Biau, S; Möstl, E; Becker-Birck, M; Morillon, B; Aurich, J; Faure, J-M; Aurich, C

    2010-04-01

    It is widely accepted that transport is stressful for horses, but only a few studies are available involving horses that are transported regularly and are accustomed to transport. We determined salivary cortisol immunoreactivity (IR), fecal cortisol metabolites, beat-to-beat (RR) interval, and heart rate variability (HRV) in transport-experienced horses (N=7) in response to a 2-d outbound road transport over 1370 km and 2-d return transport 8 d later. Salivary cortisol IR was low until 60 min before transport but had increased (PHRV variable standard deviation 2 (SD2) occurred (PHRV, which is indicative of stress. The degree of these changes tended to be most pronounced on the first day of both outbound and return transport. Copyright 2009 Elsevier Inc. All rights reserved.

  20. The rate test of speciation: estimating the likelihood of non-allopatric speciation from reproductive isolation rates in Drosophila.

    Science.gov (United States)

    Yukilevich, Roman

    2014-04-01

    Among the most debated subjects in speciation is the question of its mode. Although allopatric (geographical) speciation is assumed the null model, the importance of parapatric and sympatric speciation is extremely difficult to assess and remains controversial. Here I develop a novel approach to distinguish these modes of speciation by studying the evolution of reproductive isolation (RI) among taxa. I focus on the Drosophila genus, for which measures of RI are known. First, I incorporate RI into age-range correlations. Plots show that almost all cases of weak RI are between allopatric taxa whereas sympatric taxa have strong RI. This either implies that most reproductive isolation (RI) was initiated in allopatry or that RI evolves too rapidly in sympatry to be captured at incipient stages. To distinguish between these explanations, I develop a new "rate test of speciation" that estimates the likelihood of non-allopatric speciation given the distribution of RI rates in allopatry versus sympatry. Most sympatric taxa were found to have likely initiated RI in allopatry. However, two putative candidate species pairs for non-allopatric speciation were identified (5% of known Drosophila). In total, this study shows how using RI measures can greatly inform us about the geographical mode of speciation in nature. © 2013 The Author(s). Evolution © 2013 The Society for the Study of Evolution.

  1. A facility for the test of large area muon chambers at high rates

    CERN Document Server

    Agosteo, S; Belli, G; Bonifas, A; Carabelli, V; Gatignon, L; Hessey, N P; Maggi, M; Peigneux, J P; Reithler, H; Silari, Marco; Vitulo, P; Wegner, M

    2000-01-01

    Operation of large area muon detectors at the future Large Hadron Collider (LHC) will be characterized by large sustained hit rates over the whole area, reaching the range of kHz/\\scm. We describe a dedicated test zone built at CERN to test the performance and the aging of the muon chambers currently under development. A radioactive source delivers photons causing the sustained rate of random hits, while a narrow beam of high energy muons is used to directly calibrate the detector performance. A system of remotely controlled lead filters serves to vary the rate of photons over four orders of magnitude, to allow the study of performance as a function of rate.

  2. A facility for the test of large-area muon chambers at high rates

    Energy Technology Data Exchange (ETDEWEB)

    Agosteo, S.; Altieri, S.; Belli, G.; Bonifas, A.; Carabelli, V.; Gatignon, L.; Hessey, N.; Maggi, M.; Peigneux, J.-P.; Reithler, H. E-mail: hans.reithler@cern.ch; Silari, M.; Vitulo, P.; Wegner, M

    2000-09-21

    Operation of large-area muon detectors at the future Large Hadron Collider (LHC) will be characterized by large sustained hit rates over the whole area, reaching the range of kHz cm{sup -2}. We describe a dedicated test zone built at CERN to test the performance and the aging of the muon chambers currently under development. A radioactive source delivers photons causing the sustained rate of random hits, while a narrow beam of high-energy muons is used to directly calibrate the detector performance. A system of remotely controlled lead filters serves to vary the rate of photons over four orders of magnitude, to allow the study of performance as a function of rate. (authors)

  3. Testing the behaviour of different kinetic models for uptake/release of radionuclides between water and sediments when implemented in a marine dispersion model

    International Nuclear Information System (INIS)

    Perianez, R.

    2004-01-01

    Three kinetic models for adsorption/release of 137 Cs between water and sediments have been tested when they are included in a previously validated dispersion model of the English Channel. Radionuclides are released to the Channel from La Hague nuclear fuel reprocessing plant (France). The kinetic models are a 1-step model consisting of a single reversible reaction, a 2-step model consisting of two consecutive reversible reactions and an irreversible model consisting of three parallel reactions: two reversible and one irreversible. The models have been tested under three typical situations that correspond to the source terms that can generally be found: instantaneous release, continuous release and redissolution of radionuclides from contaminated sediments. Differences between the models become more evident when contact times between water and sediments are larger (continuous release) and in the case of redissolution from sediments. Time scales for the redissolution process are rather different between the three models. The 1-step model produces a redissolution that is too fast when compared with experimental evidence. The irreversible model requires that saturation effects of the irreversible phase are included. Probably, the 2-step model represents the best compromise between ease and level of detail of the description of sorption/release processes

  4. Results of development and field tests of a radar-tracer system providing meteorological support to modeling hazardous technological releases

    International Nuclear Information System (INIS)

    Shershakov, V.M.; Zukov, G.P.; Kosykh, V.S.

    2003-01-01

    Full text: Radar support to systems of automated radiation monitoring requires dealing with determination of geometric characteristics of air release of radionuclides. For doing this, an air release can be labeled by chaff propagating in the air similarly to particles of radioactive substance. Then, a chaff suspension can be treated as a spatially distributed radar target and thus be detected by a radar. For a number of years the Science and Production Association 'Typhoon' of Roshydromet, Obninsk has been developing a radar tracer system (RTS) for meteorological support of modeling hazardous technological releases. In September -December 2002 experiments were conducted to test the RTS in field. This presentation contains preliminary results of testing this system. A total of 9 experiments pursuing different goals were carried out. Of them 6 experiments were conducted approximately 6 km south-west of Obninsk in the vicinity of the village of Potresovo. The first three experiments were aimed at working out interaction between the MR and LDU and assessing the chaff cloud observation distance. In doing this, radar information was not transmitted from the MR to the CCS. In the last three experiments radar information was transmitted to the CCS by cell communication lines using telephones Siemens S35 with in-built modems. The CCS was deployed in building 4/25 of SPA 'Typhoon'. All information received in the CCS was put an a map. Three experiments were conducted in the area of the Kursk NPP as part of preparations for training exercises near the village of Makarovka about 7 km north-west of the city of Kurchatov. In the first two experiments radar information from the MR was passed by cell communication channels to the CCS deployed in the laboratory of external radiation monitoring of the Kursk nuclear power plant. Experiment 3 was a demonstration and arranged during the emergency response exercises at the Kursk NPP. The MR was based on the site of the external

  5. Effect of Control Mode and Test Rate on the Measured Fracture Toughness of Advanced Ceramics

    Science.gov (United States)

    Hausmann, Bronson D.; Salem, Jonathan A.

    2018-01-01

    The effects of control mode and test rate on the measured fracture toughness of ceramics were evaluated by using chevron-notched flexure specimens in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% (statistically insignificant) variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or crack mouth opening displacement (CMOD) control gave approx. 5% (statistically significant) variation over a very wide range of rates (1 to 80 µm/m/s), with the measurements being a function of rate. However, the rate effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of a nitrogen environment during strain controlled tests, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micons/m/s). CMOD or strain control did allow stable crack extension well past maximum force, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM Test Method C1421 on fracture toughness measurement.

  6. Exploitation of 3D face-centered cubic mesoporous silica as a carrier for a poorly water soluble drug: Influence of pore size on release rate

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Wenquan; Wan, Long; Zhang, Chen; Gao, Yikun; Zheng, Xin; Jiang, Tongying; Wang, Siling, E-mail: silingwang@syphu.edu.cn

    2014-01-01

    The purposes of the present work were to explore the potential application of 3D face-centered cubic mesoporous silica (FMS) with pore size of 16.0 nm as a delivery system for poorly soluble drugs and investigate the effect of pore size on the dissolution rate. FMS with different pore sizes (16.0, 6.9 and 3.7 nm) was successfully synthesized by using Pluronic block co-polymer F127 as a template and adjusting the reaction temperatures. Celecoxib (CEL), which is a BCS class II drug, was used as a model drug and loaded into FMS with different pore sizes by the solvent deposition method at a drug–silica ratio of 1:4. Characterization using scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transformation infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), nitrogen adsorption, X-ray diffraction (XRD), and differential scanning calorimetry (DSC) was used to systematically investigate the drug loading process. The results obtained showed that CEL was in a non-crystalline state after incorporation of CEL into the pores of FMS-15 with pore size of 16.0 nm. In vitro dissolution was carried out to demonstrate the effects of FMS with different pore sizes on the release of CEL. The results obtained indicated that the dissolution rate of CEL from FMS-15 was significantly enhanced compared with pure CEL. This could be explained by supposing that CEL encountered less diffusion resistance and its crystallinity decreased due to the large pore size of 16.0 nm and the nanopore channels of FMS-15. Moreover, drug loading and pore size both play an important role in enhancing the dissolution properties for the poorly water-soluble drugs. As the pore size between 3.7 and 16.0 nm increased, the dissolution rate of CEL from FMS gradually increased. - Highlights: • Exploitation of 3D cubic mesoporous silica (16 nm) as a carrier was completed. • The release rate of CEL increased on increasing the pore size of carriers. • The crystallinity

  7. The contribution of the expanding shell test to the modeling of elastoplaticity at high strain rates

    International Nuclear Information System (INIS)

    Llorca, Fabrice; Buy, Francois

    2002-01-01

    The expanding shell test allows to load a material in the domain of high strain levels while strain rate is about 104s-1. This test submits an hemisphere to a radial expanding free flight, using a pyrotechnic device. The experiment (experimental apparatus, measurements...) is described with the difficulties encountered for the interpretation of the experimental data. Under some assumptions, the numerical transformation of radial velocities gives indications about the evolution of the strain, stress, strain rate and temperature rise, this last one being related to plastic work. We show how it is possible to associate both analytical and numerical approaches. Numerical simulation of the test is presented in a companion paper (see [Buy01]). Results obtained for copper, tantalum and TA6V4 are presented. The contribution of this test to the modeling of elastoplastic behavior is discussed and further works are proposed

  8. The corrosion rate of copper in a bentonite test package measured with electric resistance sensors

    Energy Technology Data Exchange (ETDEWEB)

    Rosborg, Bo [Division of Surface and Corrosion Science, KTH, Stockholm (Sweden); Kosec, Tadeja; Kranjc, Andrej; Kuhar, Viljem; Legat, Andraz [Slovenian National Building and Civil Engineering Institute, Ljubljana (Slovenia)

    2012-12-15

    LOT1 test parcel A2 was exposed for six years in the Aespoe Hard Rock Laboratory, which offers a realistic environment for the conditions that will prevail in a deep repository for high-level radioactive waste disposal in Sweden. The test parcel contained copper electrodes for real-time corrosion monitoring in bentonite ring 36, where the temperature was 24 deg C, and copper coupons in bentonite rings 22 and 30, where the temperature was higher. After retrieval of the test parcel in January 2006, a bentonite test package consisting of bentonite rings 35 - 37 was placed in a container and sealed with a thick layer of paraffin. Later the same year new copper electrodes were installed in the test package. In January 2007 electric resistance (ER) sensors of pure copper with a thickness of 35 {mu}m were also installed in the test package mainly to facilitate the interpretation of the results from the real-time corrosion monitoring with electrochemical techniques. The ER measurements have shown that the corrosion rate of pure copper exposed in an oxic bentonite/ saline groundwater environment at room temperate decreases slowly with time to low but measurable values. The corrosion rates estimated from the regularly performed EIS measurements replicate the ER data. Thus, for this oxic environment in which copper acquires corrosion potentials of the order of 200 mV (SHE) or higher, electrochemical measurements provide believable data. Comparing the recorded ER data with an estimate of the average corrosion rate based on comparing cross-sections from exposed and protected sensor elements, it is obvious that the former overestimates the actual corrosion rate, which is understandable. It seems as if electrochemical measurements can provide a better estimate of the corrosion rate; however, this is quite dependent on the use of proper measuring frequencies and evaluation methods. In this respect ER measurements are more reliable. It has been shown that real-time corrosion

  9. The corrosion rate of copper in a bentonite test package measured with electric resistance sensors

    International Nuclear Information System (INIS)

    Rosborg, Bo; Kosec, Tadeja; Kranjc, Andrej; Kuhar, Viljem; Legat, Andraz

    2012-12-01

    LOT1 test parcel A2 was exposed for six years in the Aespoe Hard Rock Laboratory, which offers a realistic environment for the conditions that will prevail in a deep repository for high-level radioactive waste disposal in Sweden. The test parcel contained copper electrodes for real-time corrosion monitoring in bentonite ring 36, where the temperature was 24 deg C, and copper coupons in bentonite rings 22 and 30, where the temperature was higher. After retrieval of the test parcel in January 2006, a bentonite test package consisting of bentonite rings 35 - 37 was placed in a container and sealed with a thick layer of paraffin. Later the same year new copper electrodes were installed in the test package. In January 2007 electric resistance (ER) sensors of pure copper with a thickness of 35 μm were also installed in the test package mainly to facilitate the interpretation of the results from the real-time corrosion monitoring with electrochemical techniques. The ER measurements have shown that the corrosion rate of pure copper exposed in an oxic bentonite/ saline groundwater environment at room temperate decreases slowly with time to low but measurable values. The corrosion rates estimated from the regularly performed EIS measurements replicate the ER data. Thus, for this oxic environment in which copper acquires corrosion potentials of the order of 200 mV (SHE) or higher, electrochemical measurements provide believable data. Comparing the recorded ER data with an estimate of the average corrosion rate based on comparing cross-sections from exposed and protected sensor elements, it is obvious that the former overestimates the actual corrosion rate, which is understandable. It seems as if electrochemical measurements can provide a better estimate of the corrosion rate; however, this is quite dependent on the use of proper measuring frequencies and evaluation methods. In this respect ER measurements are more reliable. It has been shown that real-time corrosion

  10. Evaluation of the tuberculin skin test and the interferon-γ release assay for TB screening in French healthcare workers

    Directory of Open Access Journals (Sweden)

    Raffi Francois

    2009-11-01

    Full Text Available Abstract Introduction Using French cut-offs for the Tuberculin Skin Test (TST, results of the TST were compared with the results of an Interferon-γ Release Assay (IGRA in Healthcare Workers (HCW after contact to AFB-positive TB patients. Methods Between May 2006 and May 2007, a total of 148 HCWs of the University Hospital in Nantes, France were tested simultaneously with IGRA und TST. A TST was considered to indicate recent latent TB infection (LTBI if an increase of >10 mm or if TST ≥ 15 mm for those with no previous TST result was observed. For those with a positive TST, chest X-ray was performed and preventive chemotherapy was offered. Results All HCWs were BCG-vaccinated. The IGRA was positive in 18.9% and TST ≥ 10 mm was observed in 65.5%. A recent LTBI was believed to be highly probable in 30.4% following TST. Agreement between IGRA and TST was low (kappa 0.041. In 10 (16.7% out of 60 HCWs who needed chest X-ray following TST the IGRA was positive. In 9 (20% out of 45 HCWs to whom preventive chemotherapy was offered following TST the IGRA was positive. Of those considered TST-negative following the French guidelines, 20.5% were IGRA-positive. In a two-step strategy - positive TST verified by IGRA - 18 out of 28 (64.3% IGRA-positive HCWs would not have been detected using French guidelines for TST interpretation. Conclusion The introduction of IGRA in contact tracings of BCG-vaccinated HCWs reduces X-rays and preventive chemotherapies. Increasing the cut-off for a positive TST does not seem to be helpful to overcome the effect of BCG vaccination on TST.

  11. Enhanced low dose rate radiation effect test on typical bipolar devices

    International Nuclear Information System (INIS)

    Liu Minbo; Chen Wei; Yao Zhibin; He Baoping; Huang Shaoyan; Sheng Jiangkun; Xiao Zhigang; Wang Zujun

    2014-01-01

    Two types of bipolar transistors and nine types bipolar integrated circuit were selected in the irradiation experiment at different "6"0Co γ dose rate. The base current of bipolar transistor and input bias current of amplifier and comparator was measured, low dose enhance factor of test device was obtained. The results show that bipolar device have enhanced low dose rate sensitivity, enhancement factor of bipolar integrated circuit was bigger than that of transistor, and enhanced low dose rate sensitivity greatly varied with different structure and process of bipolar device. (authors)

  12. Testing the control of mineral supply rates on chemical erosion in the Klamath Mountains

    Science.gov (United States)

    West, N.; Ferrier, K.

    2017-12-01

    The relationship between rates of chemical erosion and mineral supply is central to many problems in Earth science, including the role of tectonics in the global carbon cycle, nutrient supply to soils and streams via soil production, and lithologic controls on landscape evolution. We aim to test the relationship between mineral supply rates and chemical erosion in the forested uplands of the Klamath mountains, along a latitudinal transect of granodioritic plutons that spans an expected gradient in mineral supply rates associated with the geodynamic response to the migration of the Mendocino Triple Junction. We present 10Be-derived erosion rates and Zr-derived chemical depletion factors, as well as bulk soil and rock geochemistry on 10 ridgetops along the transect to test hypotheses about supply-limited and kinetically-limited chemical erosion. Previous studies in this area, comparing basin-averaged erosion rates and modeled uplift rates, suggest this region may be adjusted to an approximate steady state. Our preliminary results suggest that chemical erosion at these sites is influenced by both mineral supply rates and dissolution kinetics.

  13. Kepler Planet Detection Metrics: Per-Target Flux-Level Transit Injection Tests of TPS for Data Release 25

    Science.gov (United States)

    Burke, Christopher J.; Catanzarite, Joseph

    2017-01-01

    Quantifying the ability of a transiting planet survey to recover transit signals has commonly been accomplished through Monte-Carlo injection of transit signals into the observed data and subsequent running of the signal search algorithm (Gilliland et al., 2000; Weldrake et al., 2005; Burke et al., 2006). In order to characterize the performance of the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017) on a sample of over 200,000 stars, two complementary injection and recovery tests are utilized:1. Injection of a single transit signal per target into the image or pixel-level data, hereafter referred to as pixel-level transit injection (PLTI), with subsequent processing through the Photometric Analysis (PA), Presearch Data Conditioning (PDC), Transiting Planet Search (TPS), and Data Validation (DV) modules of the Kepler pipeline. The PLTI quantification of the Kepler pipeline's completeness has been described previously by Christiansen et al. (2015, 2016); the completeness of the final SOC 9.3 Kepler pipeline acting on the Data Release 25 (DR25) light curves is described by Christiansen (2017).2. Injection of multiple transit signals per target into the normalized flux time series data with a subsequent transit search using a stream-lined version of the Transiting Planet Search (TPS) module. This test, hereafter referred to as flux-level transit injection (FLTI), is the subject of this document. By running a heavily modified version of TPS, FLTI is able to perform many injections on selected targets and determine in some detail which injected signals are recoverable. Significant numerical efficiency gains are enabled by precomputing the data conditioning steps at the onset of TPS and limiting the search parameter space (i.e., orbital period, transit duration, and ephemeris zero-point) to a small region around each injected transit signal.The PLTI test has the advantage that it follows transit signals through all processing steps of the Kepler pipeline, and

  14. Comparison of fracture toughness (K{sub IC}) and strain energy release rate (G) of selected nuclear graphites

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Se-Hwan, E-mail: shchi@kaeri.re.kr

    2016-08-01

    The fracture behaviors of six nuclear graphite grades for a high-temperature gas-cooled reactor (HTGR), which differed in coke particle size and forming method, were characterized based on the ASTM standard graphite fracture toughness test method (ASTM D 7779-11) at room temperature. The G appeared to show good correlation with the fracture surface roughness and the G-Δa curves appeared to describe the fracture process well from crack initiation to failure. Comparison of the local (K{sub IC}) and gross (G{sub IC}, G-Δa) fracture parameters showed that the resistance to crack initiation and propagation was higher in the extruded or vibration molded medium particle size grades (PCEA, NBG-17, NBG-18: EVM group) than in the iso-molded fine particle size grades (IG-110, IG-430, NBG-25: IMF group). The ASTM may need to provide a guideline for G-Δa curve analysis. The K{sub IC} appeared to increase with specimen thickness (size).

  15. Effect of gonadotropin secretion rate on the radiosensitivity of the rat luteinizing hormone-releasing hormone neuron and gonadotroph

    International Nuclear Information System (INIS)

    Winterer, J.; Barnes, K.M.; Lichter, A.S.; Deluca, A.M.; Loriaux, D.L.; Cutler, G.B. Jr.

    1988-01-01

    To test the hypothesis that the functional state of hypothalamic LHRH neurons and pituitary gonadotrophs might alter their radiosensitivity, we determined the experimental conditions under which the gonadotropin response to castration could be impaired by a single dose of cranial irradiation. Single doses of cranial irradiation greater than 2000 rads were lethal to unshielded rats. Shielding of the oropharynx and esophagus allowed the animals to survive doses up to 5000 rads. Doses between 2000 and 5000 rads had no effect on basal gonadotropin levels for as long as 3 months after irradiation. Irradiation caused a dose- and time-dependent impairment, however, in the gonadotropin response to castration. Impairment of the gonadotropin levels of castrate animals occurred in animals that were irradiated either before or after castration. However, rats irradiated in the castrate state showed a decreased susceptibility to irradiation damage. Additionally, stimulation of the pituitary by LHRH agonist (LHRHa) 3 h before irradiation significantly reduced the impairment of gonadotropin secretion 12-20 weeks after irradiation (P less than 0.05). Thus, increased functional activity of the rat hypothalamus or pituitary at the time of irradiation, induced by either castration or acute LHRHa administration, was associated with some protection against the gonadotropin-lowering effect of irradiation. Based upon these data, we hypothesize that stimulation of gonadotropin secretion at the time of therapeutic cranial irradiation in humans might protect against subsequent impairment of gonadotropin secretion

  16. Effect of injection pressure on heat release rate and emissions in CI engine using orange skin powder diesel solution

    International Nuclear Information System (INIS)

    Purushothaman, K.; Nagarajan, G.

    2009-01-01

    Experiments have been conducted to study the effect of injection pressure on the combustion process and exhaust emissions of a direct injection diesel engine fueled with Orange Skin Powder Diesel Solution (OSPDS). Earlier investigation by the authors revealed that 30% OSPDS was optimum for better performance and emissions. In the present investigation the injection pressure was varied with 30% OSPDS and the combustion, performance and emissions characteristics were compared with those of diesel fuel. The different injection pressures studied were 215 bar, 235 bar and 255 bar. The results showed that the cylinder pressure with 30% OSPDS at 235 bar fuel injection pressure, was higher than that of diesel fuel as well as at other injection pressures. Similarly, the ignition delay was longer and with shorter combustion duration with 30% OSPDS at 235 bar injection pressure. The brake thermal efficiency was better at 235 bar than that of other fuel injection pressures with OSPDS and lower than that of diesel fuel. The NO x emission with 30% OSPDS was higher at 235 bar. The hydrocarbon and CO emissions were lower with 30% OSPDS at 235 bar. The smoke emission with 30% OSPDS was marginally lower at 235 bar and marginally higher at 215 bar than for diesel fuel. The combustion, performance and emission characteristics of the engine operating on the test fuels at 235 bar injection pressure were better than other injection pressures

  17. A poly(glycerol sebacate)-coated mesoporous bioactive glass scaffold with adjustable mechanical strength, degradation rate, controlled-release and cell behavior for bone tissue engineering.

    Science.gov (United States)

    Lin, Dan; Yang, Kai; Tang, Wei; Liu, Yutong; Yuan, Yuan; Liu, Changsheng

    2015-07-01

    Various requirements in the field of tissue engineering have motivated the development of three-dimensional scaffold with adjustable physicochemical properties and biological functions. A series of multiparameter-adjustable mesoporous bioactive glass (MBG) scaffolds with uncrosslinked poly(glycerol sebacate) (PGS) coating was prepared in this article. MBG scaffold was prepared by a modified F127/PU co-templating process and then PGS was coated by a simple adsorption and lyophilization process. Through controlling macropore parameters and PGS coating amount, the mechanical strength, degradation rate, controlled-release and cell behavior of the composite scaffold could be modulated in a wide range. PGS coating successfully endowed MBG scaffold with improved toughness and adjustable mechanical strength covering the bearing range of trabecular bone (2-12MPa). Multilevel degradation rate of the scaffold and controlled-release rate of protein from mesopore could be achieved, with little impact on the protein activity owing to an "ultralow-solvent" coating and "nano-cavity entrapment" immobilization method. In vitro studies indicated that PGS coating promoted cell attachment and proliferation in a dose-dependent manner, without affecting the osteogenic induction capacity of MBG substrate. These results first provide strong evidence that uncrosslinked PGS might also yield extraordinary achievements in traditional MBG scaffold. With the multiparameter adjustability, the composite MBG/PGS scaffolds would have a hopeful prospect in bone tissue engineering. The design considerations and coating method of this study can also be extended to other ceramic-based artificial scaffolds and are expected to provide new thoughts on development of future tissue engineering materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Evaluation through column leaching tests of metal release from contaminated estuarine sediment subject to CO2 leakages from Carbon Capture and Storage sites

    International Nuclear Information System (INIS)

    Payán, M. Cruz; Galan, Berta; Coz, Alberto; Vandecasteele, Carlo; Viguri, Javier R.

    2012-01-01

    The pH change and the release of organic matter and metals from sediment, due to the potential CO 2 acidified seawater leakages from a CCS (Carbon Capture and Storage) site are presented. Column leaching test is used to simulate a scenario where a flow of acidified seawater is in contact with recent contaminated sediment. The behavior of pH, dissolved organic carbon (DOC) and metals As, Cd, Cr, Cu, Ni, Pb, Zn, with liquid to solid (L/S) ratio and pH is analyzed. A stepwise strategy using empirical expressions and a geochemical model was conducted to fit experimental release concentrations. Despite the neutralization capacity of the seawater-carbonate rich sediment system, important acidification and releases are expected at local scale at lower pH. The obtained results would be relevant as a line of evidence input of CCS risk assessment, in an International context where strategies to mitigate the climate change would be applied. - Highlights: ► Tier structured approach for assessment of the release of metals from sediment. ► Standard column leaching test to simulate CO 2 acidified seawater CCS leakages. ► Metal and DOC release from marine sediment in contact to CO 2 acidified seawater. ► From empirical to geochemical modeling approaches of DOC and metals release in column tests. ► Contamination line of evidence input of CCS risk assessment. - Column metal release from CO 2 acidified seawater leakages in contact with estuarine contaminated sediment in CCS sites

  19. Vernonia cinerea Less. supplementation and strenuous exercise reduce smoking rate: relation to oxidative stress status and beta-endorphin release in active smokers

    Directory of Open Access Journals (Sweden)

    Yankai Araya

    2010-05-01

    Full Text Available Abstract Purpose The aim of this study was to evaluate the effects of Vernonia cinerea Less. (VC supplementation and exercise on oxidative stress biomarkers, beta-endorphin release, and the rate of cigarette smoking. Methods Volunteer smokers were randomly divided into four groups: group 1: VC supplement; group 2: exercise with VC supplement; group 3: exercise; and group 4: control. VC was prepared by wash and dry techniques and taken orally before smoking, matching the frequency of strenuous exercise (three times weekly. Before and after a two month period, exhaled carbon monoxide (CO, blood oxidative stress (malondialdehyde [MDA], nitric oxide [NOx], protein hydroperoxide [PrOOH] and total antioxidant capacity [TAC], beta-endorphin and smoking rate were measured, and statistically analyzed. Results In Group 1, MDA, PrOOH, and NOx significantly decreased, whereas TAC increased (p 0.05. In Group 3, MDA, PrOOH, NOx, TAC, and beta-endorphin levels increased significantly (p 0.05. All groups had lower levels of CO after the intervention. The smoking rate for light cigarette decreased in group 2(62.7%, 1(59.52%, 3 (53.57% and 4(14.04%, whereas in self-rolled cigarettes it decreased in group 1 (54.47%, 3 (42.30%, 2 (40% and 4 (9.2%. Conclusion Supplementation with Vernonia cinerea Less and exercise provided benefit related to reduced smoking rate, which may be related to oxidaive stress and beta-endorphine levels.

  20. Vernonia cinerea Less. supplementation and strenuous exercise reduce smoking rate: relation to oxidative stress status and beta-endorphin release in active smokers.

    Science.gov (United States)

    Leelarungrayub, Donrawee; Pratanaphon, Sainatee; Pothongsunun, Prapas; Sriboonreung, Thanyaluck; Yankai, Araya; Bloomer, Richard J

    2010-05-26

    The aim of this study was to evaluate the effects of Vernonia cinerea Less. (VC) supplementation and exercise on oxidative stress biomarkers, beta-endorphin release, and the rate of cigarette smoking. Volunteer smokers were randomly divided into four groups: group 1: VC supplement; group 2: exercise with VC supplement; group 3: exercise; and group 4: control. VC was prepared by wash and dry techniques and taken orally before smoking, matching the frequency of strenuous exercise (three times weekly). Before and after a two month period, exhaled carbon monoxide (CO), blood oxidative stress (malondialdehyde [MDA], nitric oxide [NOx], protein hydroperoxide [PrOOH] and total antioxidant capacity [TAC]), beta-endorphin and smoking rate were measured, and statistically analyzed. In Group 1, MDA, PrOOH, and NOx significantly decreased, whereas TAC increased (p 0.05). In Group 3, MDA, PrOOH, NOx, TAC, and beta-endorphin levels increased significantly (p stress variables or beta-endorphine levels (p > 0.05). All groups had lower levels of CO after the intervention. The smoking rate for light cigarette decreased in group 2(62.7%), 1(59.52%), 3 (53.57%) and 4(14.04%), whereas in self-rolled cigarettes it decreased in group 1 (54.47%), 3 (42.30%), 2 (40%) and 4 (9.2%). Supplementation with Vernonia cinerea Less and exercise provided benefit related to reduced smoking rate, which may be related to oxidaive stress and beta-endorphine levels.

  1. Sludge Batch 5 Slurry Fed Melt Rate Furnace Test with Frits 418 and 550

    International Nuclear Information System (INIS)

    Miller, Donald; Pickenheim, Bradley

    2009-01-01

    Based on Melt Rate Furnace (MRF) testing for the Sludge Batch 5 (SB5) projected composition and assessments of the potential frits with reasonable operating windows, the Savannah River National Laboratory (SRNL) recommended Slurry Fed Melt Rate Furnace (SMRF) testing with Frits 418 and 550. DWPF is currently using Frit 418 with SB5 based on SRNL's recommendation due to its ability to accommodate significant sodium variation in the sludge composition. However, experience with high boron containing frits in DWPF indicated a potential advantage for Frit 550 might exist. Therefore, SRNL performed SMRF testing to assess Frit 550's potential advantages. The results of SMRF testing with SB5 simulant indicate that there is no appreciable difference in melt rate between Frit 418 and Frit 550 at a targeted 34 weight % waste loading. Both batches exhibited comparable behavior when delivered through the feed tube by the peristaltic pump. Limited observation of the cold cap during both runs showed no indication of major cold cap mounding. MRF testing, performed after the SMRF runs due to time constraints, with the same two Slurry Mix Evaporator (SME) dried products led to the same conclusion. Although visual observations of the cross-sectioned MRF beakers indicated differences in the appearance of the two systems, the measured melt rates were both ∼0.6 in/hr. Therefore, SRNL does not recommend a change from Frit 418 for the initial SB5 processing in DWPF. Once the actual SB5 composition is known and revised projections of SB5 after the neptunium stream addition and any decants is provided, SRNL will perform an additional compositional window assessment with Frit 418. If requested, SRNL can also include other potential frits in this assessment should processing of SB5 with Frit 418 result in less than desirable melter throughput in DWPF. The frits would then be subjected to melt rate testing at SRNL to determine any potential advantages

  2. An integrated device for magnetically-driven drug release and in situ quantitative measurements: Design, fabrication and testing

    Energy Technology Data Exchange (ETDEWEB)

    Bruvera, I.J. [Aragon Institute of Nanoscience (INA), University of Zaragoza, 50018 (Spain); Hernández, R.; Mijangos, C. [Instituto de Ciencia y Tecnología de Polímeros, CSIC, Juan Cierva 3, E-28006 Madrid (Spain); Goya, G.F., E-mail: goya@unizar.es [Aragon Institute of Nanoscience (INA), University of Zaragoza, 50018 (Spain); Condensed Matter Physics Department, Science Faculty, University of Zaragoza, 50009 (Spain)

    2015-03-01

    We have developed a device capable of remote triggering and in situ quantification of therapeutic drugs, based on magnetically-responsive hydrogels of poly (N-isopropylacrylamide) and alginate (PNiPAAm). The heating efficiency of these hydrogels measured by their specific power absorption (SPA) values showed that the values between 100 and 300 W/g of the material were high enough to reach the lower critical solution temperature (LCST) of the polymeric matrix within few minutes. The drug release through application of AC magnetic fields could be controlled by time-modulated field pulses in order to deliver the desired amount of drug. Using B12 vitamin as a concept drug, the device was calibrated to measure amounts of drug released as small as 25(2)×10{sup −9} g, demonstrating the potential of this device for very precise quantitative control of drug release. - Highlights: • A device for magnetically driven drug release was developed and constructed. • Thermally responsive PNiPAAm and Fe3O4 nanoparticles were usedas drug reservoir. • The device allowed repetitive, remote and precisely controlled drug release. • By in situ spectrometry we could detect released drug quantities as small as 25 ng. • Released drug was controlled through magnetic ac field parameters H, f and time.

  3. An integrated device for magnetically-driven drug release and in situ quantitative measurements: Design, fabrication and testing

    International Nuclear Information System (INIS)

    Bruvera, I.J.; Hernández, R.; Mijangos, C.; Goya, G.F.

    2015-01-01

    We have developed a device capable of remote triggering and in situ quantification of therapeutic drugs, based on magnetically-responsive hydrogels of poly (N-isopropylacrylamide) and alginate (PNiPAAm). The heating efficiency of these hydrogels measured by their specific power absorption (SPA) values showed that the values between 100 and 300 W/g of the material were high enough to reach the lower critical solution temperature (LCST) of the polymeric matrix within few minutes. The drug release through application of AC magnetic fields could be controlled by time-modulated field pulses in order to deliver the desired amount of drug. Using B12 vitamin as a concept drug, the device was calibrated to measure amounts of drug released as small as 25(2)×10 −9 g, demonstrating the potential of this device for very precise quantitative control of drug release. - Highlights: • A device for magnetically driven drug release was developed and constructed. • Thermally responsive PNiPAAm and Fe3O4 nanoparticles were usedas drug reservoir. • The device allowed repetitive, remote and precisely controlled drug release. • By in situ spectrometry we could detect released drug quantities as small as 25 ng. • Released drug was controlled through magnetic ac field parameters H, f and time

  4. Impact of lowering ski binding settings on the outcome of the self-release test of ski bindings among female recreational skiers

    Directory of Open Access Journals (Sweden)

    Posch M

    2017-12-01

    Full Text Available Markus Posch,1 Martin Burtscher,1 Alois Schranz,2 Katja Tecklenburg,2 Kenneth Helle,2 Gerhard Ruedl1 1Department of Sport Science, University of Innsbruck, Innsbruck, Austria; 2Medalp Sportclinic, Imst, Austria Background and purpose: The ability to successfully self-release the ski binding can prevent skiing-related injuries of the lower extremities. Failure of binding release associated with a knee injury is significantly higher among females compared to males. The International Standards Organization ISO 11088 standard for binding setting values allows a lowering by 15% upon request of the skier. Thus, the aim of this study was to evaluate the impact of lowered ski binding settings by 15% on the outcome of the self-release test among female recreational skiers. Materials and methods: In this randomized single-blinded study, a cohort of 20 females (24.5±2.7 years performed the self-release test in the laboratory thrice with each leg under two conditions: 1 with an actual ISO 11088 setting and 2 with a setting lowered by 15%. For each attempt, torques calculated via the force plate were normalized to torques measured by a binding adjustment system (relative release torque, RRT. Results: Among 240 trials in total, more females were significantly able to self-release their ski bindings with lowered binding settings when compared to their actual ISO settings (53% vs 9%, p<0.001. Thirteen females (65% were able to release their bindings at least once with both legs with lowered binding settings compared to only three females (15% with their actual binding settings (p<0.001. Mean RRT of all failure of binding release trials significantly differed between lowered and actual binding settings (58.6%±22.2% vs 50.5%±20.4%, p=0.003. Conclusion: Four times more females were able to self-release their ski bindings at least once with both legs with a 15% lowered binding setting compared to their normal ISO 11088 setting. The fact that the ISO standard

  5. Dose rates as a function of time due to postulated radionuclide releases from the U.S. Yucca Mountain high-level radioactive waste repository

    International Nuclear Information System (INIS)

    Moeller, Dade W.; Sun, Lin-Shen C.; Cherry, Robert

    2008-01-01

    The Yucca Mountain repository, which is located in a remote area in the State of Nevada, is being constructed for the long-term care and disposal of spent nuclear fuel and vitrified high-level radioactive waste. In accordance with U.S. law, the U.S. Environmental Protection Agency (USEPA) promulgated Standards that limit the dose rates to members of the public due to the consumption of ground water, alone, and the consumption of ground water plus agricultural products irrigated with the contaminated ground water, and other exposures, such as those from external sources and the inhalation of airborne radioactive materials. As part of this exercise, the USEPA identified eight specific radionuclides to which their Standards are to apply. These are: 14 C, 99 Tc, 129 I, 226 Ra, 228 Ra, 237 Np, 239 Pu, and 241 Am. For purposes of the associated dose rate estimates, a range of conservative assumptions have been applied, all of which are designed to assure that the estimated dose rates are well above what might be expected under 'real-world' conditions. As a first step, it was assumed that: (1) at 10 4 year after repository closure, a fractional release of 10 -5 of the entire repository radionuclide inventory occurred; (2) the only prior reduction in the inventory was that due to radioactive decay; and (3) the sole path of exposure to neighboring population groups was through the consumption of 2 L d -1 of contaminated ground water. The accompanying analyses revealed that, of the eight radionuclides, only 226 Ra, 237 Np, and 239 Pu, will represent a significant source of dose at that time. To provide perspective and insights, the next step was to estimate the committed effective dose rates for all eight radionuclides based on an assumed fractional release each year of 10 -5 of the inventory from the time of repository closure up through the 10 6 year. For purposes of providing perspective, it was assumed that each dose rate estimate was independent, that is, no releases

  6. 78 FR 71036 - Pipeline Safety: Random Drug Testing Rate; Contractor Management Information System Reporting...

    Science.gov (United States)

    2013-11-27

    ... PHMSA-2013-0248] Pipeline Safety: Random Drug Testing Rate; Contractor Management Information System Reporting; and Obtaining Drug and Alcohol Management Information System Sign-In Information AGENCY: Pipeline... Management Information System (MIS) Data; and New Method for Operators to Obtain User Name and Password for...

  7. Do exchange rates follow random walks? A variance ratio test of the ...

    African Journals Online (AJOL)

    The random-walk hypothesis in foreign-exchange rates market is one of the most researched areas, particularly in developed economies. However, emerging markets in sub-Saharan Africa have received little attention in this regard. This study applies Lo and MacKinlay's (1988) conventional variance ratio test and Wright's ...

  8. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  9. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US .... Arterial blood pressure from nonvascular access arm was measured by aneroid sphygmomanometer. The patients did not .... to detect differences in treatments across multiple test attempts. P < 0.05 ...

  10. Description of the blowdown test facility COG program on in-reactor fission product release, transport, and deposition under severe accident conditions

    International Nuclear Information System (INIS)

    Fehrenbach, P.J.; Wood, J.C.

    1987-06-01

    Loss-of-coolant accidents with additional impairment of emergency cooling would probably result in high fuel temperatures leading to severe fuel damage (SFD) and significant fission product activity would then be transported along the PHTS to the break where a fraction of it would be released and transport under such conditions, there are many interacting and sometimes competing phenomena to consider. Laboratory simulations are being used to provide data on these individual phenomena, such as UO 2 oxidation and Zr-UO 2 interaction, from which mathematical models can be constructed. These are then combined into computer codes to include the interaction effects and assess the overall releases. In addition, in-reactor tests are the only source of data on release and transport of short-lived fission product nuclides, which are important in the consequence analysis of CANDU reactor accidents. Post-test decontamination of an in-reactor test facility also provides a unique opportunity to demonstrate techniques and obtain decontamination data relevant to post-accident rehabilitation of CANDU power reactors. Specialized facilities are required for in-reactor testing because of the extensive release of radioactive fission products and the high temperatures involved (up to 2500 degrees Celsius). To meet this need for the Canadian program, the Blowdown Test Facility (BTF) has been built in the NRU reactor at Chalk River. Between completion of construction in mid-1987 and the first Zircaloy-sheathed fuel test in fiscal year 1987/88, several commissioning tests are being performed. Similarly, extensive development work has been completed to permit application of instrumentation to irradiated fuel elements, and in support of post-test fuel assembly examination. A program of decontamination studies has also been developed to generate information relevant to post-accident decontamination of power reactors. The BTF shared cost test program funded by the COG High Temperature

  11. Negativization rates of IgE radioimmunoassay and basophil activation test in immediate reactions to penicillins.

    Science.gov (United States)

    Fernández, T D; Torres, M J; Blanca-López, N; Rodríguez-Bada, J L; Gomez, E; Canto, G; Mayorga, C; Blanca, M

    2009-02-01

    Skin test sensitivity in patients with immediate allergy to penicillins tends to decrease over time, but no information is available concerning in vitro tests. We analysed the negativization rates of two in vitro methods that determine specific immunoglobulin E (IgE) antibodies, the basophil activation test using flow cytometry (BAT) and the radioallergosorbent test (RAST), in immediate allergic reactions to penicillins. Forty-one patients with immediate allergic reactions to amoxicillin were followed up over a 4-year period. BAT and RAST were performed at 6-month intervals. Patients were randomized into groups: Group I, skin tests carried out at regular intervals; Group II, skin tests made only at the beginning of the study. Differences were observed between RAST and BAT (P testing influenced the rate of negativization of the RAST assay, contributing to maintenance of in vitro sensitivity. Because of the loss of sensitivity over time, the determination of specific IgE antibodies to penicillins in patients with immediate allergic reactions must be done as soon as possible after the reaction.

  12. Constant extension rate testing of Type 304L stainless steel in simulated waste tank environments

    International Nuclear Information System (INIS)

    Wiersma, B.J.

    1992-01-01

    New tanks for storage of low level radioactive wastes will be constructed at the Savannah River Site (SRS) of AISI Type 304L stainless steel (304L). The presence of chlorides and fluorides in the wastes may induce Stress Corrosion Cracking (SCC) in 304L. Constant Extension Rate Tests (CERT) were performed to determine the susceptibility of 304L to SCC in simulated wastes. In five of the six tests conducted thus far 304L was not susceptible to SCC in the simulated waste environments. Conflicting results were obtained in the final test and will be resolved by further tests. For comparison purposes the CERT tests were also performed with A537 carbon steel, a material similar to that utilized for the existing nuclear waste storage tanks at SRS

  13. The PWR integrated leak rate test, a review of experiences and results

    International Nuclear Information System (INIS)

    Keogh, P.

    1985-01-01

    The paper reviews the Integrated Leak Rate Test (ILRT) as it has been carried out in the USA and as reported in papers in European countries. The test procedures are critically appraised and recommendations are given for modifications to them. The values used in a PWR are identified as a main source of leaks and possibilities for improvement are discussed. The use of a part pressure test and its limitations are considered. A part pressure test cannot give the same assurance as a full pressure test but may be useful for the identification of gross leaks. Secondary effects such as weather and the use of Van de Waals equations are considered and are found to be not important for concrete containments. (orig.)

  14. To determine the slow shearing rate for consolidation drained shear box tests

    Science.gov (United States)

    Jamalludin, Damanhuri; Ahmad, Azura; Nordin, Mohd Mustaqim Mohd; Hashim, Mohamad Zain; Ibrahim, Anas; Ahmad, Fauziah

    2017-08-01

    Slope failures always occur in Malaysia especially during the rainy seasons. They cause damage to properties and fatalities. In this study, a total of 24 one dimensional consolidation tests were carried out on soil samples taken from 16 slope failures in Penang Island and in Baling, Kedah. The slope failures in Penang Island are within the granitic residual soil while in Baling, Kedah they are situated within the sedimentary residual soil. Most of the disturbed soil samples were taken at 100mm depth from the existing soil surface while some soil samples were also taken at 400, 700 and 1000mm depths from the existing soil surface. They were immediately placed in 2 layers of plastic bag to prevent moisture loss. Field bulk density tests were also carried out at all the locations where soil samples were taken. The field bulk density results were later used to re-compact the soil samples for the consolidation tests. The objective of the research is to determine the slow shearing rate to be used in consolidated drained shear box for residual soils taken from slope failures so that the effective shear strength parameters can be determined. One dimensional consolidation tests were used to determine the slow shearing rate. The slow shearing rate found in this study to be used in the consolidated drained shear box tests especially for Northern Malaysian residual soils was 0.286mm/minute.

  15. Swelling, erosion and drug release characteristics of salbutamol sulfate from hydroxypropyl methylcellulose-based matrix tablets.

    Science.gov (United States)

    Chaibva, Faith A; Khamanga, Sandile M M; Walker, Roderick B

    2010-12-01

    Hydrophilic matrix formulations are important and simple technologies that are used to manufacture sustained release dosage forms. Hydroxypropyl methylcellulose-based matrix tablets, with and without additives, were manufactured to investigate the rate of hydration, rate of erosion, and rate and mechanism of drug release. Scanning electron microscopy was used to assess changes in the microstructure of the tablets during drug release testing and whether these changes could be related to the rate of drug release from the formulations. The results revealed that the rate of hydration and erosion was dependent on the polymer combination(s) used, which in turn affected the rate and mechanism of drug release from these formulations. It was also apparent that changes in the microstructure of matrix tablets could be related to the different rates of drug release that were observed from the test formulations. The use of scanning electron microscopy provides useful information to further understand drug release mechanisms from matrix tablets.

  16. Loading rate and test temperature effects on fracture of in situ niobium silicide-niobium composites

    International Nuclear Information System (INIS)

    Rigney, J.D.; Lewandowski, J.J.

    1996-01-01

    Arc cast, extruded, and heat-treated in situ composites of niobium silicide (Nb 5 Si 3 ) intermetallic with niobium phases (primary--Nb p and secondary--Nb s ) exhibited high fracture resistance in comparison to monolithic Nb 5 Si 3 . In toughness tests conducted at 298 K and slow applied loading rates, the fracture process proceeded by the microcracking of the Nb 5 Si 3 and plastic deformation of the Nb p and Nb s phases, producing resistance-curve behavior and toughnesses of 28 MPa√m with damage zone lengths less than 500 microm. The effects of changes in the Nb p yield strength and fracture behavior on the measured toughnesses were investigated by varying the loading rates during fracture tests at both 77 and 298 K. Quantitative fractography was utilized to completely characterize each fracture surface created at 298 K in order to determine the type of fracture mode (i.e., dimpled, cleavage) exhibited by the Nb p . Specimens tested at either higher loading rates or lower test temperatures consistently exhibited a greater amount of cleavage fracture in the Nb p , while the Nb s always remained ductile. However, the fracture toughness values determined from experiments spanning six orders of magnitude in loading rate at 298 and 77 K exhibited little variation, even under conditions when the majority of Nb p phases failed by cleavage at 77 K. The changes in fracture mode with increasing loading rate and/or decreasing test temperature and their effects on fracture toughness are rationalized by comparison to existing theoretical models