WorldWideScience

Sample records for relative dose contributions

  1. Occupational Doses and the Contribution to the Population Dose in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seung Jae; Kyu, Hwan Jeong [KINS, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  2. Occupational Doses and the Contribution to the Population Dose in Korea

    International Nuclear Information System (INIS)

    Han, Seung Jae; Kyu, Hwan Jeong

    2016-01-01

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  3. Internal Mammary Lymph Node Irradiation Contributes to Heart Dose in Breast Cancer

    International Nuclear Information System (INIS)

    Chargari, Cyrus; Castadot, Pierre; MacDermed, Dhara; Vandekerkhove, Christophe; Bourgois, Nicolas; Van Houtte, Paul; Magne, Nicolas

    2010-01-01

    We assessed the impact of internal mammary chain radiotherapy (IMC RT) to the radiation dose received by the heart in terms of heart dose-volume histogram (DVH). Thirty-six consecutive breast cancer patients presenting with indications for IMC RT were enrolled in a prospective study. The IMC was treated by a standard conformal RT technique (50 Gy). For each patient, a cardiac DVH was generated by taking into account the sole contribution of IMC RT. Cardiac HDV were compared according to breast cancer laterality and the type of previous surgical procedure, simple mastectomy or breast conservative therapy (BCT). The contribution of IMC RT to the heart dose was significantly greater for patients with left-sided versus right-sided tumors (13.8% and 12.8% for left-sided tumors versus 3.9% and 4.2% for right-sided tumors in the BCT group and the mastectomy group, respectively; p < 0.0001). There was no statistically significant difference in IMC contribution depending on the initial surgical procedure. IMC RT contributes to cardiac dose for both left-sided and right-sided breast cancers, although the relative contribution is greater in patients with left-sided tumors.

  4. Agriculture-related radiation dose calculations

    International Nuclear Information System (INIS)

    Furr, J.M.; Mayberry, J.J.; Waite, D.A.

    1987-10-01

    Estimates of radiation dose to the public must be made at each stage in the identification and qualification process leading to siting a high-level nuclear waste repository. Specifically considering the ingestion pathway, this paper examines questions of reliability and adequacy of dose calculations in relation to five stages of data availability (geologic province, region, area, location, and mass balance) and three methods of calculation (population, population/food production, and food production driven). Calculations were done using the model PABLM with data for the Permian and Palo Duro Basins and the Deaf Smith County area. Extra effort expended in gathering agricultural data at succeeding environmental characterization levels does not appear justified, since dose estimates do not differ greatly; that effort would be better spent determining usage of food types that contribute most to the total dose; and that consumption rate and the air dispersion factor are critical to assessment of radiation dose via the ingestion pathway. 17 refs., 9 figs., 32 tabs

  5. Scoping calculation for components of the cow-milk dose pathway for evaluating the dose contribution from iodine-131

    International Nuclear Information System (INIS)

    Ikenberry, T.A.; Napier, B.A.

    1992-12-01

    A series of scoping calculations have been undertaken to evaluate The absolute and relative contribution of different exposure pathways to doses that may have been received by individuals living in the vicinity of the Hanford site. This scoping calculation (Calculation 001) examined the contributions of the various exposure pathways associated with environmental transport and accumulation of iodine-131 in the pasture-cow-milk pathway. Addressed in this calculation were the contributions to thyroid dose of infants and adult from (1) the ingestion by dairy cattle of various feedstuffs (pasturage, silage, alfalfa hay, and grass hay) in four different feeding regimes; (2) ingestion of soil by dairy cattle; (3) ingestion of stared feed on which airborne iodine-131 had been deposited; and (4) inhalation of airborne iodine-131 by dairy cows

  6. Patient dose in image guided radiotherapy: Monte Carlo study of the CBCT dose contribution

    OpenAIRE

    Leotta, Salvatore; Amato, Ernesto; Settineri, Nicola; Basile, Emilia; Italiano, Antonio; Auditore, Lucrezia; Santacaterina, Anna; Pergolizzi, Stefano

    2018-01-01

    Image Guided RadioTherapy (IGRT) is a technique whose diffusion is growing thanks to the well-recognized gain in accuracy of dose delivery. However, multiple Cone Beam Computed Tomography (CBCT) scans add dose to patients, and its contribution has to be assessed and minimized. Aim of our work was to evaluate, through Monte Carlo simulations, organ doses in IGRT due to CBCT and therapeutic MV irradiation in head-neck, thorax and pelvis districts. We developed a Monte Carlo simulation in GAMOS ...

  7. Primordial radionuclides in soil and their contributions to absorbed dose rate in air

    International Nuclear Information System (INIS)

    Moriones, C.R.; Duran, E.B.; Cruz, F.M. de la

    1989-01-01

    The predominant primordial radionuclides in soil which give rise to terrestrial radiation (external irradiation) were analyzed by gamma spectrometry. 40 K has the highest average activity mass concentration, i.e. 212 Bq kg -1 . 238 U and 232 Th concentrations are much lower and are only 14 and 16 Bq kg -1 respectively. Based on conversion factors given in the UNSCEAR Report (1988), the absorbed dose rates in air at one meter above the ground surface per unit activity mass concentration of primordial radionuclides were calculated. The average per caput absorbed dose rate in air received by Filipinos due to terrestrial radiation is 23 nGy h -1 . The relative contribution of 232 Th series to the total absorbed dose rate is highest, followed closely by 40 K. The contribution of 238 U series is only about one-half that of the 232 Th series. Based on the results obtained, the terrestrial component of the average per caput exposure dose rate due to natural radiation sources is 2.64 μR h -1 or roughly 3 μR h -1 . This leads to an annual average effective dose equivalent to 202 μSv. (Author). 5 annexes; 4 figs.; 3 tabs.; 6 refs

  8. Contributions to indoor gamma dose rate from building materials

    International Nuclear Information System (INIS)

    Liu Xionghua; Li Guangming; Yang Xiangdong

    1990-01-01

    In the coures of construction of a building structured with bricks and concrets, the indoor gamma air absorbed dose rates were seperately measured from the floors, brick walls and prefabricated plates of concrets, etc.. It suggested that the indoor gamma dose rates from building materials are mainly attributed to the brick walls and the floors. A little contribution comes from other brilding materials. The dose rates can be calculated through a 4π-infinite thick model with a correction factor of 0.52

  9. Should we ignore U-235 series contribution to dose?

    International Nuclear Information System (INIS)

    Beaugelin-Seiller, Karine; Goulet, Richard; Mihok, Steve; Beresford, Nicholas A.

    2016-01-01

    Environmental Risk Assessment (ERA) methodology for radioactive substances is an important regulatory tool for assessing the safety of licensed nuclear facilities for wildlife, and the environment as a whole. ERAs are therefore expected to be both fit for purpose and conservative. When uranium isotopes are assessed, there are many radioactive decay products which could be considered. However, risk assessors usually assume 235 U and its daughters contribute negligibly to radiological dose. The validity of this assumption has not been tested: what might the 235 U family contribution be and how does the estimate depend on the assumptions applied? In this paper we address this question by considering aquatic wildlife in Canadian lakes exposed to historic uranium mining practices. A full theoretical approach was used, in parallel to a more realistic assessment based on measurements of several elements of the U decay chains. The 235 U family contribution varied between about 4% and 75% of the total dose rate depending on the assumptions of the equilibrium state of the decay chains. Hence, ignoring the 235 U series will not result in conservative dose assessments for wildlife. These arguments provide a strong case for more in situ measurements of the important members of the 235 U chain and for its consideration in dose assessments. - Highlights: • Realistic ecological risk assessment infers a complete inventory of radionuclides. • U-235 family may not be minor when assessing total dose rates experienced by biota. • There is a need to investigate the real state of equilibrium decay of U chains. • There is a need to improve the capacity to measure all elements of the U decay chains.

  10. The contribution to surface dose form air scatter in mega voltage photon beams

    International Nuclear Information System (INIS)

    Carolan, M.G.; Butson, M.; Metcalfe, P.

    1996-01-01

    . MCNP simulations were performed for these geometries with and without air in the region above the phantom. Simulations were also performed for the 10 x 10 cm field with various thicknesses of air immediately above the phantom. The aim here is to investigate what the relative contributions to surface dose are from different regions in the air layer. Air slices 1, 5, 10 and 20 cm thick were used as well as a simulation with the full 100 cm source - surface volume filled with air. To validate the Monte Carlo calculations we compared predicted doses at depth with dose measurements using an ion chamber and found good agreement. Dose measurements using an Attix ionisation chamber in the build up region were also in agreement with the Monte Carlo predicted doses in this region when a full column of air was included in the model. Without air included in the model the predicted surface dose was ∼ 9.5% of D max . With an air layer of 20 cm immediately above the phantom the surface dose was ∼ 13% of D max . This increased to 14.5% when the full 100 cm of air was included. All of these results take into account scatter and buildup in air only. Any experimental measurements may be expected to yield slightly higher surface doses due to scatter contribution from collimators etc in the linac head. Experimental validation of this predicted result is planned using a thin walled helium volume above the phantom surface

  11. Cosmic-ray contribution in measurement of environmental gamma-ray dose

    International Nuclear Information System (INIS)

    Nagaoka, Kazunori; Honda, Kouichirou; Miyano, Keiji

    1996-01-01

    Nowadays several kinds of dosimeters are being used for environmental gamma-ray monitoring. However the results measured by those instruments are not always in good agreement. It may be caused from the different characteristics of dosimeters. In particular the different responses of the instruments to cosmic-rays give significant influence on the results. Environmental radiation measurements at various altitudes on Mt. Fuji were carried out using a scintillation spectrometer with 3''φ spherical NaI(Tl), a pressurized ionization chamber (PIC), an air-equivalent ionization chamber (IC), thermoluminescence dosimeters (TLD), radiophotoluminescence glass dosimeters (RPLD) and NaI(Tl) scintillation survey meters so that the response characteristics of these instruments to cosmic-rays could be clarified. Cosmic-ray contributions for all instruments were correlated with counting rate over 3 MeV by the spectrometer. Each contribution can be estimated by measurement of the counting rate. Conversion factors (nGy/h/cpm) for IC, PIC, TLD, RPLD and NaI survey meters (TCS166 and TCS121C) were 0.33, 0.32, 0.25, 0.24, 0.06 and -0.01, respectively. Self-doses of these instruments were estimated by measurements at Nokogiriyama facilities of the Institute for Cosmic Ray Research, University of Tokyo. Self-doses for TLD and RPLD were approximately 6 nGy/h. The self dose effect should be taken into consideration in environmental dose measurements. These data are expected to be useful in estimating the cosmic-ray contribution and self-dose in the measurement of environmental gamma-ray dose. (author)

  12. Determination of key radionuclides and parameters related to dose from the Columbia River pathway

    International Nuclear Information System (INIS)

    Napier, B.A.

    1993-03-01

    A series of scoping calculations has been undertaken to evaluate the absolute and relative contributions of different radionuclides and exposure pathways to doses that may have been received by individuals living in the vicinity of the Hanford Site. These scoping calculations may include some radionuclides and pathways that were included in the Phase 1 Columbia River pathway dose evaluations, as well as other potential exposure pathways being evaluated for possible inclusion in future Hanford Environmental Dose Reconstruction Project (HEDR) modeling efforts. This scoping calculation (Calculation 009) examines the contributions of numerous radionuclides to dose via environmental exposures and accumulation in water, fish, and other aquatic biota. Addressed in these calculations are the contributions to effective dose from (1) external exposure to contaminated river water, ( 2) ingestion of contaminated drinking water, and (3) ingestion of contaminated resident Columbia River fish. Additional information on contamination of anadromous fish and waterfowl is provided

  13. Dose contribution from metabolized organically bound tritium after chronic tritiated water intakes in humans

    International Nuclear Information System (INIS)

    Trivedi, A.; Lamothe, E.; Galeriu, D.

    2001-01-01

    dose contribution from organically bound tritium, relative to body water dose, is in agreement with current recommendations of assigning 10% of total body water dose for organically bound tritium in soft tissues after tritiated water intakes. (authors)

  14. Radon-222 related influence on ambient gamma dose.

    Science.gov (United States)

    Melintescu, A; Chambers, S D; Crawford, J; Williams, A G; Zorila, B; Galeriu, D

    2018-04-03

    Ambient gamma dose, radon, and rainfall have been monitored in southern Bucharest, Romania, from 2010 to 2016. The seasonal cycle of background ambient gamma dose peaked between July and October (100-105 nSv h -1 ), with minimum values in February (75-80 nSv h -1 ), the time of maximum snow cover. Based on 10 m a.g.l. radon concentrations, the ambient gamma dose increased by around 1 nSv h -1 for every 5 Bq m -3 increase in radon. Radon variability attributable to diurnal changes in atmospheric mixing contributed less than 15 nSv h -1 to the overall variability in ambient gamma dose, a factor of 4 more than synoptic timescale changes in air mass fetch. By contrast, precipitation-related enhancements of the ambient gamma dose were 15-80 nSv h -1 . To facilitate routine analysis, and account in part for occasional equipment failure, an automated method for identifying precipitation spikes in the ambient gamma dose was developed. Lastly, a simple model for predicting rainfall-related enhancement of the ambient gamma dose is tested against rainfall observations from events of contrasting duration and intensity. Results are also compared with those from previously published models of simple and complex formulation. Generally, the model performed very well. When simulations underestimated observations the absolute difference was typically less than the natural variability in ambient gamma dose arising from atmospheric mixing influences. Consequently, combined use of the automated event detection method and the simple model of this study could enable the ambient gamma dose "attention limit" (which indicates a potential radiological emergency) to be reduced from 200 to 400% above background to 25-50%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. The relative biological effectiveness of out-of-field dose

    International Nuclear Information System (INIS)

    Balderson, Michael; Koger, Brandon; Kirkby, Charles

    2016-01-01

    Purpose: using simulations and models derived from existing literature, this work investigates relative biological effectiveness (RBE) for out-of-field radiation and attempts to quantify the relative magnitudes of different contributing phenomena (spectral, bystander, and low dose hypersensitivity effects). Specific attention is paid to external beam radiotherapy treatments for prostate cancer. Materials and methods: using different biological models that account for spectral, bystander, and low dose hypersensitivity effects, the RBE was calculated for different points moving radially out from isocentre for a typical single arc VMAT prostate case. The RBE was found by taking the ratio of the equivalent dose with the physical dose. Equivalent doses were calculated by determining what physical dose would be necessary to produce the same overall biological effect as that predicted using the different biological models. Results: spectral effects changed the RBE out-of-field less than 2%, whereas response models incorporating low dose hypersensitivity and bystander effects resulted in a much more profound change of the RBE for out-of-field doses. The bystander effect had the largest RBE for points located just outside the edge of the primary radiation beam in the cranial caudal (z-direction) compared to low dose hypersensitivity and spectral effects. In the coplanar direction, bystander effect played the largest role in enhancing the RBE for points up to 8.75 cm from isocentre. Conclusions: spectral, bystander, and low dose hypersensitivity effects can all increase the RBE for out-of-field radiation doses. In most cases, bystander effects seem to play the largest role followed by low dose hypersensitivity. Spectral effects were unlikely to be of any clinical significance. Bystander, low dose hypersensitivity, and spectral effect increased the RBE much more in the cranial caudal direction (z-direction) compared with the coplanar directions. (paper)

  16. Determination of the contribution of livestock water ingestion to dose from the cow-milk pathway

    International Nuclear Information System (INIS)

    Ikenberry, T.A.

    1992-12-01

    As part of the Hanford Environmental Dose Reconstruction (HEDR) Project, a series of calculations has been undertaken to evaluate the absolute and relative contribution of different exposure pathways to thyroid doses that may have been received by individuals living in the vicinity of the Hanford Site. These evaluations include some pathways that were included in the Phase I air-pathway dose evaluations (HEDR staff 1991, page xx), as well as other potential exposure pathways being evaluated for possible inclusion in the future HEDR modeling efforts. This calculation (002) examined the possible doses that may have been received by individuals who drank milk from cows that drank from sources of water (stock tanks and farm ponds) exposed to iodine-131 in the atmosphere during 1945

  17. Assessment of dose contribution to population exposure from the radiation sources in the alienated Chernobyl zone

    International Nuclear Information System (INIS)

    Grodzinsky, D.M.; Francevych, L.K.; Koval, H.N.; Yakovlev, E.A.; Bezdrobny, Yu.V.; Proscura, N.I.; Pyantkowsky, V.L.

    1997-01-01

    The main dose load of Ukrainian population is caused by radionuclide-contamination of country territories, located outside the alienated zone, following Chernobyl accident. Besides, much attention could be devoted to the contribution of dose load on population, received from the radioactivity sources that were transferred out from the zone after accident. Present research and analysis of the available documents reflecting the transfer of radioactivity from the alienated zone, provided the estimates of dose load on population, resulting from transfer of the radioactivity sources via following channels: (1) direct surface flow; (2) underground waters; (3) wind-powdered route; (4) transfer with hydrobionts; (5) transfer during irrigation; (6) biogenic route; (7) transport routes and (8) route during wood transportation. Dynamics of radiation transfer through each channel was also studied for the post-accident period. Specific gravity of radioactivity transfer is determined in relation to dose load on Ukrainian population in different regions, in particular, in Dnipro river basin. The perspectives of radioactivity transfer via each of studied channels and its role in dose load on population were also analyzed. On the basis of present results the recommendations on possible arrangements are working out that aimed to reduce the dose contribution in population exposure by radioactivity source transfer from the alienated zone via channels that stipulate the largest dose loads and collective doses

  18. Patient dose in image guided radiotherapy: Monte Carlo study of the CBCT dose contribution

    Directory of Open Access Journals (Sweden)

    Salvatore Leotta

    2018-02-01

    Full Text Available Image Guided RadioTherapy (IGRT is a technique whose diffusion is growing thanks to the well-recognized gain in accuracy of dose delivery. However, multiple Cone Beam Computed Tomography (CBCT scans add dose to patients, and its contribution has to be assessed and minimized. Aim of our work was to evaluate, through Monte Carlo simulations, organ doses in IGRT due to CBCT and therapeutic MV irradiation in head-neck, thorax and pelvis districts. We developed a Monte Carlo simulation in GAMOS (Geant4-based Architecture for Medicine-Oriented Simulations, reproducing an Elekta Synergy medical linac operating at 6 and 10 MV photon energy, and we set up a scalable anthropomorphic model. After a validation by comparison with the experimental quality indexes, we evaluated the average doses to all organs and tissues belonging to the model for the three cases of irradiated district. Scattered radiation in therapy is larger than that diffused by CBCT by one to two orders of magnitude.

  19. The relative importance of ingestion for multiple pathway dose assessments

    International Nuclear Information System (INIS)

    Wicker, W.; Grogan, H.; Bergstroem, U.; Hoffman, O.

    1991-01-01

    The general purpose of this report is to examine the relative importance of ingestion pathways, and particularly food chain transport in overall dose assessment. The importance of ingestion pathways is examined for various release scenarios and radionuclides because the findings are expected to differ with circumstances. The degree to which contaminated food products contribute to the total dose will affect the importance of accuracy and uncertainty of food chain model predictions, which is the main thrust of the Biospheric Model Validation Study (BIOMOVS). This analysis requires that all modes of radiation exposure be examined, including inhalation, external exposure, and the various ingestion pathways. (2 figs., 2 tabs.)

  20. Considering job-related doses in Europe

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    As part of its role of safeguarding nuclear workers the Commission of the European Community has created a European data bank on job-related doses. The data bank is intended to correlate jobs and workers doses and is a useful instrument to observe the collected doses of workers in nuclear power plants. Set up in 1980, the database covers doses in PWRs and BWRs. To create it a questionnaire is distributed to plant operators. The database responses provide information on (i) Trends in total collective doses, including those for some ancillary jobs. It is possible to see trends by calendar year and by fuel cycle number. (ii) Other trends such as dose in terms of installed power or dose in terms of power station design. (iii) Dose differences between power stations, normalized against the differences in dose rates. This is only possible for PWRs that monitor dose rates using the EPRI standard monitoring programme. (vi) The relative dose rate in each plant for a defined job. The questionnaire is not perfectly adapted to all the working criteria in nuclear power stations but it is an effective tool for implementing radiation protection. (author)

  1. Quantitative investigation of physical factors contributing to gold nanoparticle-mediated proton dose enhancement

    International Nuclear Information System (INIS)

    Cho, Jongmin; Manohar, Nivedh; Kerr, Matthew; Cho, Sang Hyun; Gonzalez-Lepera, Carlos; Krishnan, Sunil

    2016-01-01

    Some investigators have shown tumor cell killing enhancement in vitro and tumor regression in mice associated with the loading of gold nanoparticles (GNPs) before proton treatments. Several Monte Carlo (MC) investigations have also demonstrated GNP-mediated proton dose enhancement. However, further studies need to be done to quantify the individual physical factors that contribute to the dose enhancement or cell-kill enhancement (or radiosensitization). Thus, the current study investigated the contributions of particle-induced x-ray emission (PIXE), particle-induced gamma-ray emission (PIGE), Auger and secondary electrons, and activation products towards the total dose enhancement. Specifically, GNP-mediated dose enhancement was measured using strips of radiochromic film that were inserted into vials of cylindrical GNPs, i.e. gold nanorods (GNRs), dispersed in a saline solution (0.3 mg of GNRs/g or 0.03% of GNRs by weight), as well as vials containing water only, before proton irradiation. MC simulations were also performed with the tool for particle simulation code using the film measurement setup. Additionally, a high-purity germanium detector system was used to measure the photon spectrum originating from activation products created from the interaction of protons and spherical GNPs present in a saline solution (20 mg of GNPs/g or 2% of GNPs by weight). The dose enhancement due to PIXE/PIGE recorded on the films in the GNR-loaded saline solution was less than the experimental uncertainty of the film dosimetry (<2%). MC simulations showed highly localized dose enhancement (up to a factor 17) in the immediate vicinity (<100 nm) of GNRs, compared with hypothetical water nanorods (WNRs), mostly due to GNR-originated Auger/secondary electrons; however, the average dose enhancement over the entire GNR-loaded vial was found to be minimal (0.1%). The dose enhancement due to the activation products from GNPs was minimal (<0.1%) as well. In conclusion, under the

  2. Contribution of radon in natural gas to the dose from aiborne radon-daughters in homes

    International Nuclear Information System (INIS)

    Barton, C.J.; Moore, R.E.; Rohwer, P.S.

    1973-01-01

    Data have been obtained on the radon concentration in natural gas supplied to several metropolitan areas in the United States. The average value of 20 pCi/l was selected to estimate the contribution of this source of natural radioactivity to doses from radon-daughters received by individuals in homes. Radon-daughter concentrations in the home atmosphere were calculated by use of computer programs for an 8000 ft 3 house in which 27 ft 3 of gas per day was used for cooking in an unvented kitchen range. The total estimated dose to the bronchial epithelium included contributions from radon plus daughters in the outside ventilation air, each of which was assumed to be present at a concentration of 0.13 pCi/l, and from the radon plus daughters in the natural gas. The latter contribution averaged approximately 3 percent of the total dose. There was a 3.5 percent decrease in the estimated total dose when the air change rate increased from 0.25 to 2.0 per hour. We conclude that radon and radon-daughters entering the home with natural gas produce a negligible fraction of the total dose to the respiratory system of home occupants from airborne radon-daughters

  3. Shutdown dose rate contribution from diagnostics in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, M.S., E-mail: munseong@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Pak, S.; An, Y.H.; Seon, C.R.; Lee, H.G. [National Fusion Research Institute, Daejeon (Korea, Republic of); Bertalot, L.; Krasilnikov, V. [ITER Organization, St Paul-lez-Durance (France); Zvonkov, A. [Agency ITER-RF, Moscow (Russian Federation)

    2016-11-01

    Highlights: • The Shutdown Dose Rate in the interspace of ITER upper port 18 was evaluated. • VUV spectrometer is the dominant contributor to the average SDR. • The existence and size of the blanket cooling pipes impacts significantly on SDR. - Abstract: D-T operation of ITER plasma will produce high-energy fusion neutrons those can activate materials around the place where human-access is necessary. The interspace of the diagnostic port is one of the area where human-access is necessary for the maintenance of diagnostic systems installed at the port, so it is important to evaluate a dose rate of the interspace area in order to comply with ALARA principle. The shutdown dose rate (SDR) in the interspace of ITER upper port 18 was evaluated by the Direct 1-Step (D1S) method using MCNP5 code. This port contains three diagnostics: Vacuum Ultra-Violet (VUV) Spectrometer, Neutron Activation System (NAS), and Upper Vertical Neutron Camera (UVNC). The contribution of each diagnostic in the port was evaluated by running separate upper port MCNP models those contain individual diagnostic only, and the total dose rate contribution was evaluated with the model which was fully integrated with all the diagnostics. The effect of the opening around the upper port plug and of the other ports was also investigated. The purpose of this assessment is to provide the shielding design basis for the preliminary design of the diagnostic integration in the port. The method and result of the calculation will be presented in this paper.

  4. Health effects of low doses at low dose rates: dose-response relationship modeling in a cohort of workers of the nuclear industry; Effets sanitaires des faibles doses a faibles debits de dose: modelisation de la relation dose-reponse dans une cohorte de travailleurs du nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Metz-Flamant, Camille

    2011-09-19

    The aim of this thesis is to contribute to a better understanding of the health effects of chronic external low doses of ionising radiation. This work is based on the French cohort of CEA-AREVA NC nuclear workers. The mains stages of this thesis were (1) conducting a review of epidemiological studies on nuclear workers, (2) completing the database and performing a descriptive analysis of the cohort, (3) quantifying risk by different statistical methods and (4) modelling the exposure-time-risk relationship. The cohort includes monitored workers employed more than one year between 1950 and 1994 at CEA or AREVA NC companies. Individual annual external exposure, history of work, vital status and causes of death were reconstructed for each worker. Standardized mortality ratios using French national mortality rates as external reference were computed. Exposure-risk analysis was conducted in the cohort using the linear excess relative risk model, based on both Poisson regression and Cox model. Time dependent modifying factors were investigated by adding an interaction term in the model or by using exposure time windows. The cohort includes 36, 769 workers, followed-up until age 60 in average. During the 1968- 2004 period, 5, 443 deaths, 2, 213 cancers, 62 leukemia and 1, 314 cardiovascular diseases were recorded. Among the 57% exposed workers, the mean cumulative dose was 21.5 milli-sieverts (mSv). A strong Healthy Worker Effect is observed in the cohort. Significant elevated risks of pleura cancer and melanoma deaths were observed in the cohort but not associated with dose. No significant association was observed with solid cancers, lung cancer and cardiovascular diseases. A significant dose-response relationship was observed for leukemia excluding chronic lymphatic leukemia, mainly for doses received less than 15 years before and for yearly dose rates higher than 10 mSv. This PhD work contributes to the evaluation of risks associated to chronic external radiation

  5. Sources of radioactivity in the marine environment and their relative contributions to overall dose assessment from marine radioactivity (MARDOS). Final report of a co-ordinated research programme

    International Nuclear Information System (INIS)

    1995-10-01

    The document provides data on radionuclide levels in the marine environment and estimates doses from marine radioactivity through ingestion of sea food. Two radionuclides -natural Po210 and Cs 137 -are studied, as they are radiologically the most important representatives of each class of marine radioactivity on global scale. The results of the study confirm that the dominant contribution to doses comes from natural Po 210 in fish and shellfish and that the contribution of anthropogenic Sc 137 (mostly coming from nuclear weapons test) is negligible (100 to 1000 time lower) 14 refs, 12 figs, 13 tabs

  6. Sources of radioactivity in the marine environment and their relative contributions to overall dose assessment from marine radioactivity (MARDOS). Final report of a co-ordinated research programme

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The document provides data on radionuclide levels in the marine environment and estimates doses from marine radioactivity through ingestion of sea food. Two radionuclides -natural Po210 and Cs 137 -are studied, as they are radiologically the most important representatives of each class of marine radioactivity on global scale. The results of the study confirm that the dominant contribution to doses comes from natural Po 210 in fish and shellfish and that the contribution of anthropogenic Sc 137 (mostly coming from nuclear weapons test) is negligible (100 to 1000 time lower) 14 refs, 12 figs, 13 tabs.

  7. Primary and scattering contributions to beta scaled dose point kernels by means of Monte Carlo simulations

    International Nuclear Information System (INIS)

    Valente, Mauro; Botta, Francesca; Pedroli, Guido

    2012-01-01

    Beta-emitters have proved to be appropriate for radioimmunotherapy. The dosimetric characterization of each radionuclide has to be carefully investigated. One usual and practical dosimetric approach is the calculation of dose distribution from a unit point source emitting particles according to any radionuclide of interest, which is known as dose point kernel. Absorbed dose distributions are due to primary and radiation scattering contributions. This work presented a method capable of performing dose distributions for nuclear medicine dosimetry by means of Monte Carlo methods. Dedicated subroutines have been developed in order to separately compute primary and scattering contributions to the total absorbed dose, performing particle transport up to 1 keV or least. Preliminarily, the suitability of the calculation method has been satisfactory, being tested for monoenergetic sources, and it was further applied to the characterization of different beta-minus radionuclides of nuclear medicine interests for radioimmunotherapy. (author)

  8. The Contribution of Cytomegalovirus Infection to Immune Senescence Is Set by the Infectious Dose

    Directory of Open Access Journals (Sweden)

    Anke Redeker

    2018-01-01

    Full Text Available The relationship between human cytomegalovirus (HCMV infections and accelerated immune senescence is controversial. Whereas some studies reported a CMV-associated impaired capacity to control heterologous infections at old age, other studies could not confirm this. We hypothesized that these discrepancies might relate to the variability in the infectious dose of CMV occurring in real life. Here, we investigated the influence of persistent CMV infection on immune perturbations and specifically addressed the role of the infectious dose on the contribution of CMV to accelerated immune senescence. We show in experimental mouse models that the degree of mouse CMV (MCMV-specific memory CD8+ T cell accumulation and the phenotypic T cell profile are directly influenced by the infectious dose, and data on HCMV-specific T cells indicate a similar connection. Detailed cluster analysis of the memory CD8+ T cell development showed that high-dose infection causes a differentiation pathway that progresses faster throughout the life span of the host, suggesting a virus–host balance that is influenced by aging and infectious dose. Importantly, short-term MCMV infection in adult mice is not disadvantageous for heterologous superinfection with lymphocytic choriomeningitis virus (LCMV. However, following long-term CMV infection the strength of the CD8+ T cell immunity to LCMV superinfection was affected by the initial CMV infectious dose, wherein a high infectious dose was found to be a prerequisite for impaired heterologous immunity. Altogether our results underscore the importance of stratification based on the size and differentiation of the CMV-specific memory T cell pools for the impact on immune senescence, and indicate that reduction of the latent/lytic viral load can be beneficial to diminish CMV-associated immune senescence.

  9. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  10. The contribution of interventional cardiology procedures to the population radiation dose in a ‘health-care level I’ representative region

    Science.gov (United States)

    Peruzzo Cornetto, Andrea; Aimonetto, Stefania; Pisano, Francesco; Giudice, Marcello; Sicuro, Marco; Meloni, Teodoro; Tofani, Santi

    2016-01-01

    This study evaluates per-procedure, collective and per capita effective dose to the population by interventional cardiology (IC) procedures performed during 2002–11 at the main hospital of Aosta Valley Region that can be considered as representative of the health-care level I countries, as defined by the UNSCEAR, based on its socio-demographic characteristics. IC procedures investigated were often multiple procedures in patients older than 60 y. The median extreme dose-area product values of 300 and 22 908 cGycm2 were found for standard pacemaker implantation and coronary angioplasty, respectively, while the relative mean per-procedure effective dose ranged from 0.7 to 47 mSv. A 3-fold increase in frequency has been observed together with a correlated increase in the delivered per capita dose (0.05–0.27 mSv y−1) and the collective dose (5.8–35 man Sv y−1). Doses increased particularly from 2008 onwards mainly because of the introduction of coronary angioplasty procedures in the authors’ institution. IC practice contributed remarkably in terms of effective dose to the population, delivering ∼10 % of the total dose by medical ionising radiation examination categories. PMID:26012484

  11. Comprehensive analysis of a medication dosing error related to CPOE.

    Science.gov (United States)

    Horsky, Jan; Kuperman, Gilad J; Patel, Vimla L

    2005-01-01

    This case study of a serious medication error demonstrates the necessity of a comprehensive methodology for the analysis of failures in interaction between humans and information systems. The authors used a novel approach to analyze a dosing error related to computer-based ordering of potassium chloride (KCl). The method included a chronological reconstruction of events and their interdependencies from provider order entry usage logs, semistructured interviews with involved clinicians, and interface usability inspection of the ordering system. Information collected from all sources was compared and evaluated to understand how the error evolved and propagated through the system. In this case, the error was the product of faults in interaction among human and system agents that methods limited in scope to their distinct analytical domains would not identify. The authors characterized errors in several converging aspects of the drug ordering process: confusing on-screen laboratory results review, system usability difficulties, user training problems, and suboptimal clinical system safeguards that all contributed to a serious dosing error. The results of the authors' analysis were used to formulate specific recommendations for interface layout and functionality modifications, suggest new user alerts, propose changes to user training, and address error-prone steps of the KCl ordering process to reduce the risk of future medication dosing errors.

  12. SU-E-T-517: Investigation of Factors Contributing to Extracranial Radiation Doses From Leksell Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Kon, D [The University of Tokyo Graduate school of Medicine, Tokyo, JP (Japan); Kameda Medical Centre, Chiba, JP (Japan); Nakano, M [The University of Tokyo Graduate school of Medicine, Tokyo, JP (Japan); Nawa, K; Haga, A; Nakagawa, K [University of Tokyo Hospital, Tokyo, JP (Japan)

    2015-06-15

    Purpose The purpose of this study is to investigate dominant factors for doses to extracranial sites in treatment with Leksell Gamma Knife (LGK). Methods Monte Carlo simulation was implemented using EGS5 version 1.4.401. The simulation was divided into two major steps for the purpose of efficiency. As the first step, phase-space files were obtained at a scoring plane located just below patient-side surface of the collimator helmet of LGK. Scored particles were classified into three groups, primary, leakage and scatter, using their history information until their arrival to the scoring plane. Then classification was used at the following second step simulation to investigate which type of particle is dominant in the deposited energy at extra-cranial sites. In the second stage, a cylindrical phantom with a semisphere shaped head was modeled such that the geometrical center of the phantom’s head corresponds to the unit center point (UCP) of LGK. Scoring regions were arranged at 10 cm intervals from the UCP to 70 cm away on the central axis of the phantom. Energy deposition from each type of particles and location of interaction were recorded. Results The dominant factor of deposited energy depended on the collimator size. In the case of smaller collimator size, leakage was dominant. However, contribution of leakage was relatively small in the case of larger collimator size. The contribution of internal scatter varied with the distance from the UCP. In the proximal areas, internal scatter was dominant, whereas in the distal areas, particles interacting with machine components became dominant factor. Conclusion The Result of this study indicates that the dominant factor to dose to an extracranial site can vary with the distance from UCP and with collimator size. This means that the variation of this contribution must be considered for modeling of the extracranial dose especially in the distal area. This work was partly supported by the JSPS Core-to-Core Program (No

  13. Paediatric radiology and scientific contributions to radiation dose at the meeting of the German Radiological Society-An analysis of an 11-year period

    International Nuclear Information System (INIS)

    Heyer, Christoph M.; Lemburg, Stefan P.; Peters, Soeren A.

    2010-01-01

    Aim: Evaluation of the emphasis on themes pertaining to paediatric radiology and radiation dose at the Meeting of the German Radiological Society from 1998 to 2008 in comparison to international data. Materials and methods: Retrospective analysis of 9440 abstracts with documentation of type of contribution, imaging modality, and examined body region. Abstracts primarily dealing with paediatric radiology and those stating radiation dose were documented. Results were compared with a Pubmed query. Results: 448 contributions in paediatric radiology were presented corresponding to 5% of all abstracts with an increase from 5 (1998) to 7% (2008). The proportion of prospective studies of all congress contributions was 10%, whereas in paediatric radiology, the share of prospective studies was 6%. From 1998 to 2008, the share of MRI fell from 48 to 38%, while CT contributions rose from 30 to 34%. Within paediatric radiology, the proportion of CT rose from 23 to 29%, while MRI and ultrasound fell from 63 to 48% and 35 to 19%, respectively. The share of abstracts dealing with radiation dose rose from 7 to 10% while that primarily pertaining to dose reduction grew from 2 to 4%. Of all abstracts concerning CT, 15% touched on radiation dose, whereas 6% primarily dealt with dose reduction. Among all abstracts dealing with paediatric radiology, 20 and 6% mentioned radiation dose and dose reduction, respectively. In the subgroup of paediatric radiology CT abstracts, radiation dose and dose reduction were mentioned in 34 and 16%, respectively. An online query produced 137,791 publications on CT, of whose abstracts 3% mentioned radiation dose and 0.5% mentioned dose reduction. 11% of all CT publications dealt with paediatric populations and 2% of these publications examined questions of radiation dose. Conclusions: In the last 11 years the Meeting of the German Radiological Society has presented a growing number of contributions pertaining to paediatric radiology. CT has shown the

  14. Contribution of the height in the ambient dose equivalent; Contribuicao da altitude no equivalente de dose ambiente

    Energy Technology Data Exchange (ETDEWEB)

    de Campos, Vicente de P.; Manzoli, Jose E.; Alipio, Osvaldo C.; Carneiro, Janete C.G.; Rodrigues Junior, Orlando, E-mail: vpcampos@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The aim of this study is to evaluate the contribution of natural sources in the ambient dose equivalent. The evaluation of the levels of environmental radiation was performed using thermoluminescent dosimeters CaSO{sub 4} of doped C, which have high sensitivity and little fading. The dosimeters were placed in five locations at different altitudes, covering the period from three to nine years depending on their location. The results were grouped according to the use and occupation of land in the vicinity of the measurement point.

  15. Consequences of the exposure at low dose rates-contribution of animal experimentation

    International Nuclear Information System (INIS)

    Masse, R.

    1990-01-01

    The exposure of laboratory animals to the various types of radiations will induce cancers in relation with the tissue absorbed doses. The shape of the dose-effet relationship is most variable. It is important to distinguish which tumours are comparable to human tumours. Those showing more analogies answer but seldom to the classical lineo-quadratic relationship; however, a strong attenuation of induction is demonstrated at low dose rates. Quasi-threshold relationships are seen after the exposure of some tissues to high-LET radiations. These observations question the validity of generalizing the radiobiologists' dual action theory, setting the origin of the dose-effect relationship in the induction of events within the DNA molecule. There is an alternative in the cellular collaboration events; it assumes that the effectiveness per dose unit decreases constantly as an inverse function of the dose rate [fr

  16. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Devic, S; Tomic, N; DeBlois, F; Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Aldelaijan, S [King Faisal Specialist Hospital & Research Center, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis

  17. The calculation of relative output factor and depth dose for irregular electron fields in water

    International Nuclear Information System (INIS)

    Dunscombe, Peter; McGhee, Peter; Chu, Terence

    1996-01-01

    Purpose: A technique, based on sector integration and interpolation, has been developed for the computation of both relative output factor and depth dose of irregular electron fields in water. The purpose of this study was to determine the minimum experimental data set required for the technique to yield results within accepted dosimetric tolerances. Materials and Methods: PC based software has been written to perform the calculations necessary to dosimetrically characterize irregular shaped electron fields. The field outline is entered via digitiser and the SSD and energy via the keyboard. The irregular field is segmented into sectors of specified angle (2 deg. was used for this study) and the radius of each sector computed. The central ray depth dose is reconstructed by summing the contributions from each sector deduced from calibration depth doses measured for circular fields. Relative output factors and depth doses at SSDs at which calibrations were not performed are found by interpolation. Calibration data were measured for circular fields from 2 to 9 cm diameter at 100, 105, 110, and 115 cm SSD. A clinical cut out can be characterized in less than 2 minutes including entry of the outline using this software. The performance of the technique was evaluated by comparing calculated relative output factors, surface dose and the locations of d 80 , d 50 and d 20 with experimental measurements on a variety of cut out shapes at 9 and 18 MeV. The calibration data set (derived from circular cut outs) was systematically reduced to identify the minimum required to yield an accuracy consistent with current recommendations. Results: The figure illustrates the ability of the technique to calculate the depth dose for an irregular field (shown in the insert). It was found that to achieve an accuracy of 2% in relative output factor and 2% or 2 mm (our criterion) in percentage depth dose, calibration data from five circular fields at the four SSDs spanning the range 100-115 cm

  18. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  19. Status of Los Alamos efforts related to Hiroshima and Nagasaki dose estimates

    International Nuclear Information System (INIS)

    Whalen, P.P.

    1981-09-01

    The Los Alamos efforts related to resolution of the Hiroshima, Nagasaki doses are described as follows: (1) Using recently located replicas of the Hiroshima bomb, measurements will be made which will define the upper limit of the Hiroshima yield. (2) Two-dimensional calculations of the neutron and gamma-ray outputs of the Hiroshima and Nagasaki weapons are in progress. Neutron and gamma-ray leakage spectra measurements will be made. Similar measurements on the Mark 9 weapon and on the Ichiban assembly are proposed. These measurements will provide a check for present day cross sections and calculations. (3) Calculations of several air transport experiments are in progress. A comparison of calculated results with experimental results is given. (4) The neutron and gamma-ray output spectra of several devices tested in the atmosphere at the Nevada Test Site are being calculated. The results of these calculations will allow models of the debris cloud contribution to the total dose to be tested

  20. Operation of the radiation dose registration system for decontamination and related works

    International Nuclear Information System (INIS)

    Ogawa, Tsubasa; Yasutake, Tsuneo; Itoh, Atsuo; Miyabe, Kenjiro

    2017-01-01

    The radiation dose registration system for decontamination and related works was established on 15 November 2013. Radiation dose registration center and primary contractors of decontamination and related works manage decontamination registration and management system. As of 31 March 2017, 384 primary contractors joined in the radiation dose registration system for decontamination and related works. 383,087 quarterly exposure dose records for decontamination and related works were registered. Based on the registered data provided by the primary contractors, radiation dose registration center has released the statistical data that represent the radiation control status for workers engaged in radiation work at the work areas of decontamination and related works, etc. The statistical data shows that there were 40,377 workers engaged in decontamination and related works in 2015. The average exposure dose for workers was 0.6 mSv in 2015. The maximum exposure dose for workers was 7.8 mSv in 2015. Dose distribution by age of workers shows the range of 60 to 64 years old were most engaged in decontamination and related works in 2015. Dose distribution by gender of workers shows 97% of workers were male in 2015. From 2012 to 2015, about 95% of workers were exposed to radiation less than 3 mSv. And about 80% of workers were exposed to radiation less than 1 mSv. The average exposure dose per year was ranged from 0.5 to 0.7 mSv. (author)

  1. Polonium-210 concentration of cigarettes traded in Cuba and their estimated dose contribution due to smoking

    International Nuclear Information System (INIS)

    Brigido Flores, O.; Montalvan Estrada, A.; Fabelo Bonet, O.; Barreras Caballero, A.

    2015-01-01

    Cigarette smoking is one of the pathways that might contribute significantly to the increase in the radiation dose reaching man, due to the relatively large concentrations of polonium-210 found in tobacco leaves. The results of 200 Po determination on the 11 most frequently smoked brands of cigarettes and cigars which constitute over 75% of the total cigarette consumption in Cuba are presented and discussed. Moreover, the polonium content in cigarette smoke was estimated on the basis of its activity in cigarettes, ash, fresh filters and post-smoking filters. 210 Po was determined by gas flow proportional detector after spontaneous deposition of 210 Po on a high copper-content disk. The annual committed equivalent dose for lungs and the annual effective dose for smokers between 12-17 years old and for adults were calculated on the basis of the 210 Po inhalation through cigarette smoke. The results showed concentration ranging from 9.3 to 14.4 mBq per cigarette with a mean value of 11.8 ± 0.6 mBq.Cig -1 . the results of this work indicate that Cuban smokers who smoke one pack (20 cigarettes) per day inhale from 62 to 98 mBq.d -1 of 210 Po and smokers between 12-17 years old who consume 10 cigarettes daily inhale from 30-50 mBq.d -1 . The average committed equivalent dose for lungs is estimated to be 466 ± 36 and 780 ± 60 μSv.year -1 for young and adult smokers, respectively and annual committed effective dose is calculated to be 60 ± 5 and 100 ± 8 μSv for these two groups of smokers, respectively. (Author)

  2. Contribution of maternal radionuclide burdens to prenatal radiation doses: Relationships between annual limits on intake and prenatal doses

    International Nuclear Information System (INIS)

    Sikov, M.R.; Hui, T.E.

    1993-10-01

    This addendum describes approaches for calculating and expressing radiation doses to the embryo/fetus from maternal intakes of radionuclides at levels corresponding to fractions or multiples of the Annual Limits on Intake (ALI). Information, concerning metabolic or dosimetric characteristics and the placental transfer of selected, occupationally significant radionuclides was presented in NUREG/CR-5631, Revision 1. That information was used to estimate levels of radioactivity in the embryo/fetus as a function of stage of pregnancy and time after entry. Extension of MIRD methodology to accommodate gestational-stage-dependent characteristics allowed dose calculations for the simplified situation based on introduction of 1 μCi into the woman's transfer compartment (blood). The expanded scenarios in this addendum include repeated or chronic ingestion or inhalation intakes by a woman during pregnancy and body burdens at the beginning of pregnancy. Tables present dose equivalent to the embryo/fetus relative to intakes of these radionuclides in various chemical or physical forms and from preexisting maternal burdens corresponding to ALI; complementary intake values (fraction of an ALI and μCi) that yield a dose equivalent of 0.05 rem are included. Similar tables give these measures of dose equivalency to the uterus from intakes of radionuclides for use as surrogates for embryo/fetus dose when biokinetic information is not available

  3. Radiation-related operator's dose distribution according to LLD(recording level)

    International Nuclear Information System (INIS)

    Park, Jae Duck

    2008-01-01

    Recently, the area of radiation usage is being enlarged by the industry's advancement over the world. And, the usage of radiation generator and radioisotope is increasing every year. So, they are researching actively how to protect operators from the radiation that causes direct or indirect harmfulness to radiation-related operators of the related institutions. Therefore, in case of operator's dose, not only the main dosimeter's correctness but also the reasonal evaluation to the read values becomes the important factor. From this view, LLD's application to the read dose value is being embossed more importantly than any other thing. So, this study tried to find out what change was generated in the personal dose and the group dose when LLD was applied based on the internal real operator's read value, for 3 years, 2005 - 2007, and find out the personal dose change after dividing them into the exposure group and the supervising group based on the common people's personal dose (1 mSv/y)

  4. A model-based approach of scatter dose contributions and efficiency of apron shielding for radiation protection in CT.

    Science.gov (United States)

    Weber, N; Monnin, P; Elandoy, C; Ding, S

    2015-12-01

    Given the contribution of scattered radiations to patient dose in CT, apron shielding is often used for radiation protection. In this study the efficiency of apron was assessed with a model-based approach of the contributions of the four scatter sources in CT, i.e. external scattered radiations from the tube and table, internal scatter from the patient and backscatter from the shielding. For this purpose, CTDI phantoms filled with thermoluminescent dosimeters were scanned without apron, and then with an apron at 0, 2.5 and 5 cm from the primary field. Scatter from the tube was measured separately in air. The scatter contributions were separated and mathematically modelled. The protective efficiency of the apron was low, only 1.5% in scatter dose reduction on average. The apron at 0 cm from the beam lowered the dose by 7.5% at the phantom bottom but increased the dose by 2% at the top (backscatter) and did not affect the centre. When the apron was placed at 2.5 or 5 cm, the results were intermediate to the one obtained with the shielding at 0 cm and without shielding. The apron effectiveness is finally limited to the small fraction of external scattered radiation. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Estimation of population dose from all sources in Japan

    International Nuclear Information System (INIS)

    Kusama, Tomoko; Nakagawa, Takeo; Kai, Michiaki; Yoshizawa, Yasuo

    1988-01-01

    The purposes of estimation of population doses are to understand the per-caput doses of the public member from each artificial radiation source and to determine the proportion contributed of the doses from each individual source to the total irradiated population. We divided the population doses into two categories: individual-related and source-related population doses. The individual-related population dose is estimated based on the maximum assumption for use in allocation of the dose limits for members of the public. The source-related population dose is estimated both to justify the sources and practices and to optimize radiation protection. The source-related population dose, therefore, should be estimated as realistically as possible. We investigated all sources that caused exposure to the population in Japan from the above points of view

  6. Contribution of time-activity pattern and microenvironment to black carbon (BC) inhalation exposure and potential internal dose among elementary school children

    Science.gov (United States)

    Jeong, Hyeran; Park, Donguk

    2017-09-01

    The aims of this study were to quantify the contributions of activities or microenvironments (MEs) to daily total exposure to and potential dose of black carbon (BC). Daily BC exposures (24-h) were monitored using a micro-aethalometer micoAeth AE51 with forty school-aged children living in an urban area in Korea from August 2015 to January 2016. The children's time-activity patterns and the MEs they visited were investigated by means of a time-activity diary (TAD) and follow-up interviews with the children and their parents. Potential inhaled dose was estimated by multiplying the airborne BC concentrations (μg/m3) we monitored for the time the children spent in a particular ME by the inhalation rate (IR, m3/h) for the time-activity performed. The contribution of activities and MEs to overall daily exposure to and potential dose of BC was quantified. Overall mean daily potential dose was equal to 24.1 ± 10.6 μg/day (range: 6.6-46.3 μg/day). The largest contribution to BC exposure and potential dose (51.9% and 41.7% respectively) occurred in the home thanks to the large amount of time spent there. Transportation was where children received the most intense exposure to (14.8%) and potential dose (20.2%) of BC, while it accounted for 7.6% of daily time. School on weekdays during the semester was responsible for 20.3% of exposure and 22.5% of potential dose. Contribution to BC exposure and potential dose was altered by several time-activity parameters, such as type of day (weekdays vs. weekends; school days vs. holidays), season, and gender. Traveling by motor vehicle and subway showed more elevated exposure or potential dose intensity on weekdays or school days, probably influenced by the increased surrounding traffic volumes on these days compared to on weekends or holidays. This study may be used to prioritize targets for minimizing children's exposure to BC and to indicate outcomes of BC control strategies.

  7. Definition of dose intensity (DI), average relative DI and effective DI

    International Nuclear Information System (INIS)

    Alberto, P.

    1995-01-01

    The cytotoxic activity of cancer chemotherapy is related to the dose and to the amount of drug delivered per time unit. the significance of time in the effectiveness of a treatment program is frequently overlooked. The term of dose intensity (DI) is used to define the drug dose delivered per time unit and is expressed as mg/m 2 per week. A delay in the sequence of treatment cycles decreases the DI in the DI in the same proportion as a reduction of dose. Average relative DI corresponds to the mean DI of combined agents and is expressed as a fraction of a similar combination selected as a standard. Di is useful to compare the dose actually received with the prescribed dose. The relation of DI with tumor response or survival has not been fully demonstrated. A threshold DI level for therapeutic activity is evident. Above this threshold, a linear relationship of DI and effectiveness is not obvious, particularly regarding high-dose chemotherapy. The term of DI is more useful in its principle than in the significance of its calculated value. (authors). 19 refs., 3 tabs., 3 figs

  8. Analysis of surface contributions to external doses in a radioactively contaminated urban environment designed by the EMRAS-2 Urban Areas Working Group

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Jeong, Hae Sun; Jeong, Hyo Joon; Kim, Eun Han; Han, Moon Hee; Kim, In Gyu

    2013-01-01

    Highlights: ► External dose and contribution from radio-activated surface were evaluated for EMRAS-2 Urban Areas Working Group scenarios. ► The external doses showed a distinctive difference with the locations and precipitation. ► The contribution of contaminated surfaces for external dose depends on locations and precipitation. ► These results provide the essential information for decision-making support of countermeasures. - Abstract: The EMRAS-2 Urban Areas Working Group, which is supported by the IAEA, has designed a variety of accidental scenarios to test and improve the capabilities of the models used for an evaluation of radioactive contamination in an urban environment. A variety of models including a Korean model, METRO-K, are used for predictive results on the hypothetical scenarios. This paper describes the predictive results of METRO-K for the hypothetical scenarios designed in the Working Group. The external dose resulting from the air contamination of Co-60 was evaluated, and its contribution was analyzed with time as a function of the location of a receptor and precipitation conditions at the time of the contamination event. As a result, the external doses showed a distinctive difference with the locations to be evaluated and the precipitation conditions. Moreover, the contribution of contaminated surfaces for external doses was strongly dependent on the locations to be evaluated and the precipitation conditions. These results will provide essential information to assist the decision-making of appropriate countermeasures in an emergency situation of a radioactively contaminated urban environment

  9. Radiation dose to relations of patients treated with 131I

    International Nuclear Information System (INIS)

    Pant, G.S.; Sharma, S.K.; Bal, C.S.; Rakesh Kumar; Rath, G.K.

    2003-01-01

    Due to its efficacy and simplicity, radioiodine treatment of thyrotoxicosis and differentiated thyroid cancer (DTC) has become extremely popular. A large number of such patients are getting benefit with this treatment modality. Though the radiation dose to the relations of these patients, who may be in close proximity for some time after treatment have been mentioned as within safe limits but we do have sufficient data of our own in India. The life style and social conditions in India are very different than in the developed world. We have been measuring external dose in relations/attendants of these patients who have enough chance to come in close contacts with patients during and after their radioiodine treatment. The TL discs of CaSO 4 (Renentech Laboratories) were exposed to graded doses of gamma photons from 131 I for establishing a dose response relationship. The annealed discs from a given lot were measured for background counts and issued to the relations of patients who have maximum chance of being in proximity with the patient for 2 weeks. The TLDs were collected after a use of 2 weeks for dose estimation. We have so far studied 60 families with a total of 71 attendants. The external doses in all the persons attending the patients at home are well within safe prescribed limits. However, due to varied social and practical circumstances 5 persons exceeded 1 mSv dose. This is possibly due to travelling long distance by train immediately after discharge from the hospital when the accompanying person remains in close proximity throughout the journey. There are situations for non-ambulatory patients, when the attendants have to attend them for relatively longer period. (author)

  10. Concentration activities of natural radionuclides in three fish species in Brazilian coast and their contributions to the absorbed doses

    International Nuclear Information System (INIS)

    Pereira, Wagner de S.; Py Junior, Delcy de A.; Kelecom, Alphonse

    2009-01-01

    Activity concentrations of U-238, Ra-226, Pb-210, Th-232 e Ra-228 were analysed in three fish species at the Brasilian Coast. The fish 'Cubera snapper' (Lutjanus cyanopterus, Cuvier, 1828), in the region of Ceara and 'Whitemouth croaker' (Micropogonias furnieri, Desmarest, 1823) and 'Lebranche mullet' (Mugil liza, Valenciennes, 1836) in the region of Rio de Janeiro. These concentrations were transformed in absorbed dose rate using a dose conversion factor in unit of gray per year (μGy y -1 ), per becquerel per kilogram (Bq kg -1 ). Only the absorbed dose due to intake of radionuclides was examined, and the contributions due to radionuclides present in water and sediment were disregarded. The radionuclides were considered to be uniformly distributed in the fish body. The limit of the dose rate used, proposed by the Department of Energy of the USA, is equal to 3.65 10 03 mGy y -1 . The average dose rate due to the studied radionuclides is equal to 6.09 10 00 μGy y -1 , a value minor than 0.1% than the limits indicated by DOE, and quite similar to that found in the literature for 'benthic' fish. The most important radionuclides were the alpha emitters Ra-226 having 61 % of absorbed dose rate. U-238 and Th-232, each contributes with approximately 20 % of the absorbed dose rate. These three radionuclides are responsible for almost 100% of the dose rate received by the studied organisms. The beta emitters Ra-228 and Pb-210 account for approximately 1 % of the absorbed dose rate. (author)

  11. Study of the contribution of X-ray and gamma photons to the measured exposure dose

    International Nuclear Information System (INIS)

    Andriampanarivo, H.L.H.

    2000-01-01

    The aim of this work was to study the contribution of X-rays and gamma radiation to the measured dose in the city of Antananarivo. The annual indoor absorbed dose was studied as well. Measurements were carried out in twelve sites, namely public schools and churches. The mean dose rate lies between (0.34±0.03)μSv/h and (0.38±0.04)μSv/h for most of the sites. Two of them showed values between (0.40±0.04)μSv/h and (0.30±0.03)μSv/h. Mean indoor dose rate is of (0.36±0.04)μSv/h and the annual absorbed dose is (3.16±0.32)mSv/person. Indoor measurements showed mean integral values ranging from (277.22±0,22)cps to (733.66±0,37)cps. The lowest mean count rate is (277.22±0,22)cps, measured in the AMARO site, whereas the highest are (733,66±0,37)cps, (697,81±0,36)cps and (689,32±0,36)cps measured in ALO0 , AKELY, and MASINA respectively. [fr

  12. Study of the contribution of the different components of atmospheric cosmic radiation in dose received by the aircraft crew

    International Nuclear Information System (INIS)

    Pereira, Marlon A.; Prado, Adriane C.M.; Federico, Claudio A.; Goncalez, Odair L.

    2014-01-01

    The crews and aircraft passengers are exposed to atmospheric cosmic radiation. The flow of this radiation is modulated by the solar cycle and space weather, varying with the geomagnetic latitude and altitude. This paper presents a study of the contributions of radiation in total ambient dose equivalent of the crews depending on flight altitude up to 20 km, during maximum and minimum solar and in equatorial and polar regions. The results of calculations of the particle flows generated by the EXPACS and QARM codes are used. The particles evaluated that contributing significantly in the ambient dose equivalent are neutrons, protons, electrons, positrons, alphas, photons, muons and charged pions. This review allows us to characterize the origin of the dose received by crews and also support a project of a dosimetric system suitable for this ionizing radiation field in aircraft and on the ground

  13. An algorithm for intelligent sorting of CT-related dose parameters

    Science.gov (United States)

    Cook, Tessa S.; Zimmerman, Stefan L.; Steingal, Scott; Boonn, William W.; Kim, Woojin

    2011-03-01

    Imaging centers nationwide are seeking innovative means to record and monitor CT-related radiation dose in light of multiple instances of patient over-exposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose-length product (DLP)-an indirect estimate of radiation dose-requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, Arterial could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired, and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  14. An algorithm for intelligent sorting of CT-related dose parameters.

    Science.gov (United States)

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Boonn, William W; Kim, Woojin

    2012-02-01

    Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)--an indirect estimate of radiation dose--requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, "arterial" could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  15. Contribution of maternal radionuclide burdens to prenatal radiation doses

    International Nuclear Information System (INIS)

    Sikov, M.R.; Hui, T.E.; Meznarich, H.K.; Thrall, K.D.

    1992-03-01

    This report discusses approaches to calculating and expressing radiation doses to the embryo/fetus from internal radionuclides. Information was obtained for selected, occupationally significant radionuclides in chemical forms that provided a spectrum of metabolic and dosimetric characteristics. Fractional placental transfer and/or ratios of concentration in the embryo/fetus to that in the woman were estimated for these materials, and were combined with data from biokinetic transfer models to predict radioactivity levels in the embryo/fetus as a function of stage of pregnancy and time after entry into the transfer compartment or blood of the pregnant woman. Medical Internal Radiation Dosimetry (MIRD) methodologies were extended to formalize and describe details for calculating radiation absorbed doses to the embryo/fetus. Calculations were performed for representative situations; introduction of 1 μCi into a woman's blood at successive months of pregnancy was assumed to accommodate the stage dependence of geometric relationships and biological behaviors. Summary tables of results, correlations, and dosimetric relations, and of tentative generalized categorizations, are provided in the report

  16. Mammography dose in relation to body mass index, race, and menopausal status

    Energy Technology Data Exchange (ETDEWEB)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G

    2002-07-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  17. Mammography dose in relation to body mass index, race, and menopausal status

    International Nuclear Information System (INIS)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G.

    2002-01-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  18. Present dose limits and their relation to radiosensitivity of different organs and tissues

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Dose equivalent limits in relation to dose thresholds are considered for injury of various tissues and organs to evaluate the protection agains non-stochastic irradiation effects by the existing system of dose limitation for radiotherapeutic personnel. Data on tissue radiosensitivity in relation to non-stochastic effects, obtained from radiotherapeutic experience, are presented. Dose threshold values, derived for patients, with a correction in the direction of increase, may be applied to conditions of occupational exposure except for bone marrow, gonads and eye lens, where threshold doses are lower

  19. Primary and scattering contributions to beta scaled dose point kernels by means of Monte Carlo simulations; Contribuicoes primaria e espalhada para dosimetria beta calculadas pelo dose point kernels empregando simulacoes pelo Metodo Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Valente, Mauro [CONICET - Consejo Nacional de Investigaciones Cientificas y Tecnicas de La Republica Argentina (Conicet), Buenos Aires, AR (Brazil); Botta, Francesca; Pedroli, Guido [European Institute of Oncology, Milan (Italy). Medical Physics Department; Perez, Pedro, E-mail: valente@famaf.unc.edu.ar [Universidad Nacional de Cordoba, Cordoba (Argentina). Fac. de Matematica, Astronomia y Fisica (FaMAF)

    2012-07-01

    Beta-emitters have proved to be appropriate for radioimmunotherapy. The dosimetric characterization of each radionuclide has to be carefully investigated. One usual and practical dosimetric approach is the calculation of dose distribution from a unit point source emitting particles according to any radionuclide of interest, which is known as dose point kernel. Absorbed dose distributions are due to primary and radiation scattering contributions. This work presented a method capable of performing dose distributions for nuclear medicine dosimetry by means of Monte Carlo methods. Dedicated subroutines have been developed in order to separately compute primary and scattering contributions to the total absorbed dose, performing particle transport up to 1 keV or least. Preliminarily, the suitability of the calculation method has been satisfactory, being tested for monoenergetic sources, and it was further applied to the characterization of different beta-minus radionuclides of nuclear medicine interests for radioimmunotherapy. (author)

  20. Relation between dose of bendrofluazide, antihypertensive effect, and adverse biochemical effects

    DEFF Research Database (Denmark)

    Carlsen, J E; Køber, L; Torp-Pedersen, C

    1990-01-01

    OBJECTIVE--To determine the relevant dose of bendrofluazide for treating mild to moderate hypertension. DESIGN--Double blind parallel group trial of patients who were given placebo for six weeks and then randomly allocated to various doses of bendrofluazide (1.25, 2.5, 5, or 10 mg daily) or place...... of bendrofluazide to treat mild to moderate hypertension is 1.25-2.5 mg a day. Higher doses caused more pronounced adverse biochemical effects including adverse lipid effects. Previous trials with bendrofluazide have used too high doses....... relations between dose and effect were shown for potassium, urate, glucose, total cholesterol, and apolipoprotein B concentrations. The 1.25 mg dose increased only urate concentrations, whereas the 10 mg dose affected all the above biochemical variables. CONCLUSION--The relevant range of doses...

  1. Contribution of various of manufacturing of food products to internal exposure dose of population

    International Nuclear Information System (INIS)

    Bajrashevskaya, D.A.; Goncharova, N.V.

    2007-01-01

    Since 1986, considerable data have been produced and published on all the above aspects of the Cs 137 from soils to agricultural products. Today no critical evaluation of the available information has been undertaken. There is an obvious need to evaluate the relative importance of agricultural foodstuffs as a source of internal dose. The importance of food from different production systems to the internal dose from radiocaesium was investigated in selected study sites in Belarus. This work considers approaches and methods of internal exposure dose evaluation for citizens of radioactive contaminated territories consuming food products of radioactive contaminated forests. (authors)

  2. Contribution gives the cosmic radiation to the doses for exhibition to the natural radiation in the Cuban population

    International Nuclear Information System (INIS)

    Tomas Zerquera, J.; Peres Sanchez, D.; Prendes Alonso, M

    1998-01-01

    With the objective to specify the preponderant contribution the cosmic component the radiation in the dose that the Cuban population receives you carries out a program she gives mensurations she gives this component in the whole country

  3. Ameliorative effects of low dose/low dose-rate irradiation on reactive oxygen species-related diseases model mice

    International Nuclear Information System (INIS)

    Nomura, Takaharu

    2008-01-01

    Living organisms have developed complex biological system which protects themselves against environmental radiation, and irradiation with proper dose, dose-rate and irradiation time can stimulate their biological responses against oxidative stress evoked by the irradiation. Because reactive oxygen species are involved in various human diseases, non-toxic low dose/low dose-rate radiation can be utilized for the amelioration of such diseases. In this study, we used mouse experimental models for fatty liver, nephritis, diabetes, and ageing to elucidate the ameliorative effect of low dose/low dose-rate radiation in relation to endogenous antioxidant activity. Single irradiation at 0.5 Gy ameliorates carbon tetrachloride-induced fatty liver. The irradiation increases hepatic anti-oxidative system involving glutathione and glutathione peroxidase, suggesting that endogenous radical scavenger is essential for the ameliorative effect of low dose radiation on carbon tetrachloride-induced fatty liver. Single irradiation at 0.5 Gy ameliorates ferric nitrilotriacetate-induced nephritis. The irradiation increases catalase and decreases superoxide dismutase in kidney. The result suggests that low dose radiation reduced generation of hydroxide radical generation by reducing cellular hydroperoxide level. Single irradiation at 0.5 Gy at 12 week of age ameliorates incidence of type I diabetes in non-obese diabetic (NOD) mice through the suppression of inflammatory activity of splenocytes, and resultant apoptosis of β-cells in pancreas. The irradiation activities of superoxide dismutase and catalase, which coordinately diminish intracellular reactive oxygen species. Continuous irradiation at 0.70 mGy/hr from 10 week of age elongates life span, and suppresses alopecia in type II diabetesmice. The irradiation improved glucose clearance without affecting insulin-resistance, and increased pancreatic catalase activity. The results suggest that continuous low dose-rate irradiation protect

  4. The contribution to the irradiation dose of the person from 137Cs using mushrooms in food

    Directory of Open Access Journals (Sweden)

    N. E. Zarubina

    2010-06-01

    Full Text Available Results of calculations of the contribution to dose of the person irradiation from 137Cs are resulted at the use of 1 kg different species mushrooms in food. Investigations of 137Cs content in mushrooms were carried out in the territory of Kyiv area, including the alienation zone and the zone of the obligatory resettlement.

  5. Study of the anti-inflammatory effects of low-dose radiation. The contribution of biphasic regulation of the antioxidative system in endothelial cells

    International Nuclear Information System (INIS)

    Large, Martin; Hehlgans, Stephanie; Reichert, Sebastian; Roedel, Claus; Roedel, Franz; Gaipl, Udo S.; Fournier, Claudia; Weiss, Christian

    2015-01-01

    We examined (a) the expression of the antioxidative factor glutathione peroxidase (GPx) and the transcription factor nuclear factor E2-related factor 2 (Nrf2) following low-dose X-irradiation in endothelial cells (ECs) and (b) the impact of reactive oxygen species (ROS) and Nrf2 on functional properties of ECs to gain further knowledge about the anti-inflammatory mode of action of low doses of ionizing radiation. EA.hy926 ECs and primary human dermal microvascular ECs (HMVEC) were stimulated by tumor necrosis factor-α (TNF-α, 20 ng/ml) 4 h before irradiation with single doses ranging from 0.3 to 3 Gy. The expression and activity of GPx and Nrf2 were analyzed by flow cytometry, colorimetric assays, and real-time PCR. The impact of ROS and Nrf2 on peripheral blood mononuclear cell (PBMC) adhesion was assayed in the presence of the ROS scavenger N-acetyl-L-cysteine (NAC) and Nrf2 activator AI-1. Following a low-dose exposure, we observed in EA.hy926 EC and HMVECs a discontinuous expression and enzymatic activity of GPx concomitant with a lowered expression and DNA binding activity of Nrf2 that was most pronounced at a dose of 0.5 Gy. Scavenging of ROS by NAC and activation of Nrf2 by AI-1 significantly diminished a lowered adhesion of PBMC to EC at a dose of 0.5 Gy. Low-dose irradiation resulted in a nonlinear expression and activity of major compounds of the antioxidative system that might contribute to anti-inflammatory effects in stimulated ECs. (orig.) [de

  6. Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

    International Nuclear Information System (INIS)

    Fiandra, Christian; Ragona, Riccardo; Ricardi, Umberto; Anglesio, Silvia; Giglioli, Francesca Romana

    2008-01-01

    The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K sat ) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

  7. Collective dose commitments from nuclear power programmes

    International Nuclear Information System (INIS)

    Beninson, D.

    1977-01-01

    The concepts of collective dose and collective dose commitment are discussed, particularly regarding their use to compare the relative importance of the exposure from several radiation sources and to predict future annual doses from a continuing practice. The collective dose commitment contributions from occupational exposure and population exposure due to the different components of the nuclear power fuel cycle are evaluated. A special discussion is devoted to exposures delivered over a very long time by released radionuclides of long half-lives and to the use of the incomplete collective dose commitment. The maximum future annual ''per caput'' doses from present and projected nuclear power programmes are estimated

  8. Radiation dose contribution from coal-slag from the Ajka region used as structural building material

    Energy Technology Data Exchange (ETDEWEB)

    Somali, J.; Kanyar, B.; Lendvai, Z.; Nemeth, C.; Bodnar, R. [Veszpremi Egyetem, Veszprem (Hungary). Radiokemia Tanszek

    1997-10-01

    A significant dose contribution on the population could be derived from coal slags used as material in buildings. Extremely high natural activities are measured in the coal slag from the region of Ajka, Hungary. The main conclusions based on the results of the monitoring of the gamma-dose rate and the radon concentration in the air in nearly 240 houses are as follows: (1) for individuals, such as children, spending a long time at home (19.2 h/day) the external annual dose is 1.7-4.5 mSv; (2) in the majority of houses with local slag the estimated annual average value of indoor-radon concentration was above 400 Bq/m{sup 3}, and in several cases there were buildings with values over 1200 Bq/m{sup 3}. In these cases the internal annual dose of the dwellers can be estimated between 6-20 mSv; (3) due to the elevated gamma-exposure and the radon concentration in the dwellings the total annual dose was estimated as 8-24 mSv, more than 5-10 times the world average value; and (4) some of the houses were built after the 1960s, when the use of slags from the region of Ajka as building material was already banned by the authorities. In addition to the regulations an effective radiological control should be introduced and a practice for testing the use of slag as building material.

  9. 137 CS content in coconut water and copra in French Polynesia: contribution to the dose for population

    International Nuclear Information System (INIS)

    Poletiko, C.; Arnould, C.; Sarbach, J.; Bablet, J.P.; Ducousso, R.

    1992-01-01

    Coconut tree has the peculiarity to be a good integrator for alkaline metals. The isotope 137 of cesium, which was generated during previous atmospheric nuclear tests, has a high fission yield and a half-life of about 30 years; this nuclide is supposed to be still present in food chain in French Polynesia. In this food chain coconut water and coconut copra are ingested depending upon diet customs and areas of French Polynesia. For some islands, among local foodstuffs, cesium 137 content in coconut highly contributes to the dose. Spectrometry gamma results and annual doses calculation since 1966 are displayed. (author)

  10. Carcinogenesis induced by low-dose radiation

    Directory of Open Access Journals (Sweden)

    Piotrowski Igor

    2017-11-01

    Full Text Available Although the effects of high dose radiation on human cells and tissues are relatively well defined, there is no consensus regarding the effects of low and very low radiation doses on the organism. Ionizing radiation has been shown to induce gene mutations and chromosome aberrations which are known to be involved in the process of carcinogenesis. The induction of secondary cancers is a challenging long-term side effect in oncologic patients treated with radiation. Medical sources of radiation like intensity modulated radiotherapy used in cancer treatment and computed tomography used in diagnostics, deliver very low doses of radiation to large volumes of healthy tissue, which might contribute to increased cancer rates in long surviving patients and in the general population. Research shows that because of the phenomena characteristic for low dose radiation the risk of cancer induction from exposure of healthy tissues to low dose radiation can be greater than the risk calculated from linear no-threshold model. Epidemiological data collected from radiation workers and atomic bomb survivors confirms that exposure to low dose radiation can contribute to increased cancer risk and also that the risk might correlate with the age at exposure.

  11. Renal uptake of bismuth-213 and its contribution to kidney radiation dose following administration of actinium-225-labeled antibody

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, J; O' Donoghue, J A; Humm, J L [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Jaggi, J S [Bristol-Myers Squibb, Plainsboro, NJ (United States); Ruan, S; Larson, S M [Nuclear Medicine Service Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); McDevitt, M; Scheinberg, D A, E-mail: schwarj1@mskcc.org [Molecular Pharmacology and Chemistry, Sloan-Kettering Institute, 1275 York Avenue, New York, NY 10065 (United States)

    2011-02-07

    Clinical therapeutic studies using {sup 225}Ac-labeled antibodies have begun. Of major concern is renal toxicity that may result from the three alpha-emitting progeny generated following the decay of {sup 225}Ac. The purpose of this study was to determine the amount of {sup 225}Ac and non-equilibrium progeny in the mouse kidney after the injection of {sup 225}Ac-huM195 antibody and examine the dosimetric consequences. Groups of mice were sacrificed at 24, 96 and 144 h after injection with {sup 225}Ac-huM195 antibody and kidneys excised. One kidney was used for gamma ray spectroscopic measurements by a high-purity germanium (HPGe) detector. The second kidney was used to generate frozen tissue sections which were examined by digital autoradiography (DAR). Two measurements were performed on each kidney specimen: (1) immediately post-resection and (2) after sufficient time for any non-equilibrium excess {sup 213}Bi to decay completely. Comparison of these measurements enabled estimation of the amount of excess {sup 213}Bi reaching the kidney ({gamma}-ray spectroscopy) and its sub-regional distribution (DAR). The average absorbed dose to whole kidney, determined by spectroscopy, was 0.77 (SD 0.21) Gy kBq{sup -1}, of which 0.46 (SD 0.16) Gy kBq{sup -1} (i.e. 60%) was due to non-equilibrium excess {sup 213}Bi. The relative contributions to renal cortex and medulla were determined by DAR. The estimated dose to the cortex from non-equilibrium excess {sup 213}Bi (0.31 (SD 0.11) Gy kBq{sup -1}) represented {approx}46% of the total. For the medulla the dose contribution from excess {sup 213}Bi (0.81 (SD 0.28) Gy kBq{sup -1}) was {approx}80% of the total. Based on these estimates, for human patients we project a kidney-absorbed dose of 0.28 Gy MBq{sup -1} following administration of {sup 225}Ac-huM195 with non-equilibrium excess {sup 213}Bi responsible for approximately 60% of the total. Methods to reduce renal accumulation of radioactive progeny appear to be necessary for the

  12. Discrimination of various contributions to the absorbed dose in BNCT: Fricke-gel imaging and intercomparison with other experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G. E-mail: grazia.gambarini@mi.infn.it; Agosteo, S.; Marchesi, P.; Nava, E.; Palazzi, P.; Pecci, A.; Rosi, G.; Tinti, R

    2000-11-15

    A method is described for the 3D measurements of absorbed dose in a ferrous sulphate gel phantom, exposed in the thermal column of a nuclear reactor. The method, studied for Boron Neutron Capture Therapy (BNCT) purposes, allows absorbed dose imaging and profiling, with the separation of different contributions coming from different secondary radiations, generated from thermal neutrons. In fact, the biological effectiveness of the different radiations is different. Tests with conventional dosimeters were performed too.

  13. Dose and time relations in Hg(++)-induced tubular necrosis and regeneration

    DEFF Research Database (Denmark)

    Nielsen, J B; Andersen, H R; Andersen, O

    1994-01-01

    relationship is caused by a dose-related induction of kidney damage leading to increasing leakage of mercury through the kidneys. Histopathologic investigation revealed extensive necrosis of the proximal tubules in kidneys from mice exposed to 100 mumole HgCl2/kg or higher doses. Moreover, maximum renal damage...

  14. Dose contribution from metabolized organically bound tritium after acute tritiated water intakes in humans

    International Nuclear Information System (INIS)

    Trivedi, A.; Galeriu, D.; Richardson, R.B.

    1997-01-01

    Urine samples from eight male radiation workers who had an unplanned acute tritiated water intake were measured for tritium-in-urine up to 300 d post-exposure. During the first month or so post-exposure, these individuals increased their fluid intakes to accelerate the turnover rate of tritium in the body for dose mitigation. Their daily fluid intakes reverted to normal levels in the latter period of the study. A non-linear regressional analysis of the tritium-in-urine data showed that the average biological half-life of tritium in body water, with standard deviation, was 63 ± 1.0 d (range, 5.0-8.1 d) and 8.4 ± 2.0 d (range, 6.2-12.8 d) during the respective periods of increased fluid intake and the later period of normal fluid intake. A longer term component of tritium excretion was also observed with average biological half-life of 74 ± 18 d (range, 58-104 d), indicating the incorporation of tritium, and its retention, in the organic fractions of the body. A mathematical model was developed and used to estimate the dose increase from the metabolized organically bound tritium on the basis of the kinetics of tritium-in-urine. The model accounts for a change in the rates of urinary excretion caused by variable fluid intakes. The average dose to the body, for the eight male workers, due to the metabolized organically bound tritium was estimated to be 6.2 ± 1.3% (range, 3.5% to 8.9%) of the committed effective dose due to tritium in the body water. This value for the dose increase from organically bound tritium is in the range of the current recommendations of the International Commission on Radiological Protection, i.e., organically bound tritium incorporated into the body contributes about 10% of the dose to the body water following tritiated water intakes. (author)

  15. Contribution of maternal radionuclide burdens to prenatal radiation doses

    International Nuclear Information System (INIS)

    Sikov, M.R.; Hui, T.E.

    1996-05-01

    This report describes approaches to calculating and expressing radiation doses to the embryo/fetus from internal radionuclides. Information was obtained for selected, occupationally significant radioelements that provide a spectrum of metabolic and dosimetric characteristics. Evaluations are also presented for inhaled inert gases and for selected radiopharmaceuticals. Fractional placental transfer and/or ratios of concentration in the embryo/fetus to that in the woman were calculated for these materials. The ratios were integrated with data from biokinetic transfer models to estimate radioactivity levels in the embryo/fetus as a function of stage of pregnancy and time after entry into the transfer compartment or blood of the pregnant woman. These results are given as tables of deposition and retention in the embryo/fetus as a function of gestational age at exposure and elapsed time following exposure. Methodologies described by MIRD were extended to formalize and describe details for calculating radiation absorbed doses to the embryo/fetus. Calculations were performed using a model situation that assumed a single injection of 1 μCi into a woman's blood; independent calculations were performed for administration at successive months of pregnancy. Gestational -stage-dependent dosimetric tabulations are given together with tables of correlations and relationships. Generalized surrogate dose factors and categorizations are provided in the report to provide for use in operational radiological protection situations. These approaches to calculation yield radiation absorbed doses that can be converted to dose equivalent by multiplication by quality factor. Dose equivalent is the most common quantity for stating prenatal dose limits in the United States and is appropriate for the types of effect that are usually associated with prenatal exposure. If it is desired to obtain alternatives for other purposes, this value can be multiplied by appropriate weighting factors

  16. Contribution of maternal radionuclide burdens to prenatal radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Sikov, M.R.; Hui, T.E.

    1996-05-01

    This report describes approaches to calculating and expressing radiation doses to the embryo/fetus from internal radionuclides. Information was obtained for selected, occupationally significant radioelements that provide a spectrum of metabolic and dosimetric characteristics. Evaluations are also presented for inhaled inert gases and for selected radiopharmaceuticals. Fractional placental transfer and/or ratios of concentration in the embryo/fetus to that in the woman were calculated for these materials. The ratios were integrated with data from biokinetic transfer models to estimate radioactivity levels in the embryo/fetus as a function of stage of pregnancy and time after entry into the transfer compartment or blood of the pregnant woman. These results are given as tables of deposition and retention in the embryo/fetus as a function of gestational age at exposure and elapsed time following exposure. Methodologies described by MIRD were extended to formalize and describe details for calculating radiation absorbed doses to the embryo/fetus. Calculations were performed using a model situation that assumed a single injection of 1 {mu}Ci into a woman`s blood; independent calculations were performed for administration at successive months of pregnancy. Gestational -stage-dependent dosimetric tabulations are given together with tables of correlations and relationships. Generalized surrogate dose factors and categorizations are provided in the report to provide for use in operational radiological protection situations. These approaches to calculation yield radiation absorbed doses that can be converted to dose equivalent by multiplication by quality factor. Dose equivalent is the most common quantity for stating prenatal dose limits in the United States and is appropriate for the types of effect that are usually associated with prenatal exposure. If it is desired to obtain alternatives for other purposes, this value can be multiplied by appropriate weighting factors.

  17. Contribution of radiodiagnosis to genetically significant dose

    International Nuclear Information System (INIS)

    Pele, J.M.; Ouvrard, R.

    Surveys were carried out in France on 33,000 X-ray medical examinations. The genetically significant dose to the whole population from roentgenography and fluoroscopy, for typical examinations, should be about 65mrads [fr

  18. Doses of Chernobyl liquidators: Ukrainian prospective

    International Nuclear Information System (INIS)

    Chumak, Vadim V.; Bakhanova, Elena V.; Sholom, Sergey V.; Bouville, Andre; Luckyanov, Nickolas K.; Skaletsky, Yuri N.; Kryuchkov, Viktor P.

    2008-01-01

    Full text: The issue of doses received by Chernobyl clean-up workers (liquidators) remains controversial both in terms of dose values (individual and collective) and reliability of available data. This deficiency became particularly evident during preparation of the Ukrainian contribution to the UNSCEAR report. Analysis showed that available official dose records (ODR) are neither representative nor unbiased and, therefore, cannot be used to indicate the impact of Chernobyl exposure on this cohort (∼230,000 individuals). Recent developments in the area of dosimetry for liquidators contributed to better understanding of this problem and added information regarding individual, group averaged, and collective doses to Ukrainian liquidators. It was established that majority (∼95%) of existing ODR are related to one particular category of clean-up workers military liquidators. All other categories of Ukrainian liquidators either do not have recorded doses or their doses are not presented in the Chernobyl State Registry of Ukraine (SRU). The main sets of new doses were derived from reassessment of about 8,600 ODRs performed within Ukrainian-American Chernobyl Ocular Study (UACOS) and results of independent dose reconstructions using a time-and-motion method called Realistic Analytical Dose Reconstruction with Uncertainty Estimation (RADRUE) for about 1,000 subjects in the Ukrainian-American study of leukemia and related disorders among cleanup workers from Ukraine. A third source of independent dose assessments is the set of individual doses obtained using EPR spectroscopy of tooth enamel; such estimates have been performed for about 800 Ukrainian liquidators. Analysis of dosimetric information related to military liquidators, who comprise about the 48% of Ukrainian liquidators, showed that as a rule ODRs for persons in this category systematically overestimate actual doses. Quantification of this overestimation gives a clue to retrospective adjustment of doses, at

  19. Task related doses in spanish light water reactors over the period 1990-1996

    International Nuclear Information System (INIS)

    Aroca, J.; Montesinos, J.J.; O'Donnell, P.; Amor, I.; Butragueno, J.L.

    1998-01-01

    In order to evaluate in depth the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities -7 PWR (6 Westinghouse and 1 KWU-Siemens) and 2 BWR (Generic Electric), and to have a further overview of dose trends, the CSN has analysed the task related doses data over the period 1990-1996. The scope of this analysis includes the collective dose and relative relevance for 18 different refuelling outage tasks, some sub-tasks, 12 department staff, and the main consolidated dose reduction-techniques and good practices. Data has been collected from the outage reports NPPs provide according to the CSN 1.5 Safety Guide format. (Author)

  20. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  1. Dose-response relations for stricture in the proximal oesophagus from head and neck radiotherapy

    International Nuclear Information System (INIS)

    Alevronta, Eleftheria; Ahlberg, Alexander; Mavroidis, Panayiotis; Al-Abany, Massoud; Friesland, Signe; Tilikidis, Aris; Laurell, Goeran; Lind, Bengt K.

    2010-01-01

    Background and purpose: Determination of the dose-response relations for oesophageal stricture after radiotherapy of the head and neck. Material and methods: In this study 33 patients who developed oesophageal stricture and 39 patients as controls are included. The patients received radiation therapy for head and neck cancer at Karolinska University Hospital, Stockholm, Sweden. For each patient the 3D dose distribution delivered to the upper 5 cm of the oesophagus was analysed. The analysis was conducted for two periods, 1992-2000 and 2001-2005, due to the different irradiation techniques used. The fitting has been done using the relative seriality model. Results: For the treatment period 1992-2005, the mean doses were 49.8 and 33.4 Gy, respectively, for the cases and the controls. For the period 1992-2000, the mean doses for the cases and the controls were 49.9 and 45.9 Gy and for the period 2001-2005 were 49.8 and 21.4 Gy. For the period 2001-2005 the best estimates of the dose-response parameters are D 50 = 61.5 Gy (52.9-84.9 Gy), γ = 1.4 (0.8-2.6) and s = 0.1 (0.01-0.3). Conclusions: Radiation-induced strictures were found to have a dose response relation and volume dependence (low relative seriality) for the treatment period 2001-2005. However, no dose response relation was found for the complete material.

  2. Task related doses in Spanish pressurized water reactors over the period 1988-1992

    Energy Technology Data Exchange (ETDEWEB)

    O`Donnell, P.; Labarta, T.; Amor, I. [Subdireccion de Proteccion Radiologica, Madrid (Spain)

    1995-03-01

    In order to evaluate in depth the collective dose trend and its correlation with the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities, and base the different policy lines to promote this criteria, the CSN has fullfilled an analysis of the task related doses data over the period 1988-1992. Previously, the CSN had required to the utilities the compilation of their refuelling outage collective dose from 1988 according with a predeterminate number of tasks, in order to have available a representative and retrospective set of data in an homogeneous way and coherent with the international data banks on occupational exposure in NPP, as the CEC and the NEA ones. The scope of this analysis was the following: first, the collective dose summaries for outage tasks and departments for PWR and for BWR, including the minimum, maximum and average dose (and statistics data) for 18 different refuelling outage tasks and 12 personal departments for each generation of each type of rector, the task and department related collective dose trends in each plant and in each generation, and second, the dose reduction techniques having been used during that period in each plant and the relative level of adoption. In this presentation the main results and conclusions of the first part of the study are reviewed for PWR.

  3. Dose constraints for comforters and carers

    CERN Document Server

    Singleton, M; Morrison, G; Soanes, T

    2003-01-01

    This report has been prepared to enable guidance to be developed for employers, to assist them in meeting relevant legislative requirements for the exposure of persons who offer support and care to patients undergoing procedures involving ionising radiation where this would not be considered part of their occupation. The report identifies relevant legislation and guidance, discusses its interpretation, identifies circumstances in which these persons are exposed and presents information relating to the extent of these exposures, including results of dose measurements. Significant use of published information has been made, that has been supplemented wherever possible, with contributions from health care professionals. Our sincere thanks go to all persons who have contributed information or comments during the production of this report. Persons who have provided dose or related information included in this report are identified in Appendix B. This report and the work it describes was funded by the Health and Sa...

  4. Dosimetric contribution of the organs of the I123, I124 and I131 bio-kinetics in the dose estimate for euthyroid adults

    International Nuclear Information System (INIS)

    Vasquez, A. M.; Rojas, A. R.; Castillo, D. C.; Idrogo, C. J.; Flores, U. H.

    2011-10-01

    Using the formalism MIRD and the representation of Crysty-Eckerman for the thyroid adult, is demonstrated that the dosimetric contributions of source organs of the biokinetics of the radiopharmaceuticals I 123 , I 124 and I 131 (iodine) are not significant in the dose estimate. Therefore, the total absorbed dose by the gland is its auto-dose. Equally, the reported results do not present significant differences to the results found by the Marinelli scheme (auto-dose) for the thyroid represented by a sphere of 20 grams. (Author)

  5. Comparison between apparent viscosity related to irradiation dose for corn starch and black pepper

    International Nuclear Information System (INIS)

    Casandroiu, T.; Oprita, N.; Ferdes, O.S.

    1999-01-01

    Dose-effect relationship was studied in the rheoviscometric behaviour of geliffied suspensions of irradiated corn starch and black pepper, as the variation of the apparent viscosity and the shear stress related to the dose. Irradiation has been performed up to 16 kGy. Black pepper was ground and sieved to three particle sizes to analyse also the influence of particle size on the apparent viscosity variation by dose. The rheoviscometric measurements have been carried out by a rotationary viscometer on geliffied suspensions of starch and black pepper, into equivalent starch concentration and alkalinised suspensions for pepper. For starch, shear stress variation by dose is exponential, where the coefficients depend on the shear rate. For black pepper, the curves of apparent viscosity relation to dose also fit an exponential equation and the influence of particle size is discussed, too. Viscometric behaviour similar to irradiation of both corn starch and black pepper could be attributed to starch degradation at relatively high doses and should be used to develop an identification and control method for the ionizing treatment of starch-based food materials. (author)

  6. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    International Nuclear Information System (INIS)

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D

    2015-01-01

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant

  7. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant.

  8. Dose-response of women's health-related quality of life (HRQoL) and life satisfaction to physical activity.

    Science.gov (United States)

    Eime, Rochelle; Harvey, Jack; Payne, Warren

    2014-02-01

    To examine the dose-response relationship between health related quality of life (HRQoL) and life satisfaction (outcomes) and duration of recreational physical activity (exposure). Further, to explore whether these relationships depend on type of physical activity (PA). 793 Australian rural-living women self-reported on duration of recreational PA; HRQoL via SF-36 Mental Component Summary (MCS) and Physical Component Summary (PCS); and a life satisfaction scale. ANOVAs and ANCOVAs investigated differences in outcomes (MCS, PCS, and life satisfaction) between tertiles of exposure to recreational PA, and types of PA (club sport, gymnasium, walking), with adjustment for potential confounders. A significant positive dose-response relationship was found between PCS and level of PA. Furthermore, this relationship depended on type of PA, with club-sport participants recording higher PCS than non-club-sport participants in all but the highest tertile of exposure. Life satisfaction and MCS were not significantly related to level of PA. Physical health was positively associated with level of recreational PA, with club sport participation contributing greater benefits at low to moderate exposures than participation in gymnasium or walking activities.

  9. Dose-volume correlation in radiation-related late small-bowel complication

    International Nuclear Information System (INIS)

    Letschert, J.G.J.; Lebesque, J.V.; Boer, R.W. de; hart, A.A.M.; Barteling, H.

    1990-01-01

    The effects of the volume of irradiated small bowel on late small-bowel tolerance was studied, taking into account the equivalent total dose ant type of pre-irradiation surgical procedure. A method was developed to estimate small-bowel volumes in the high-bowel volumes were measured for three-field and AP-PA pelvic treatments (165 cm 3 and 400 cm 3 , respectively), extended AP-PA treatment of para-aortic and iliac nodes (1000 cm 3 ). In a retrospective study of 111 patientst irradiated after surgery for rectal or recto-sigmoid cancer to a dose of 45-50 Gy in 5 weeks, extended AP-PA pelvic treatment (n = 27) resulted in a high incidence of severe small-bowel complications (37%), whereas for limited (three-field) pelvic treatment (n = 84) the complication rate was 6%. These complication data together with data from the literature on postoperative radiation-related small-bowel complications were analysed using the maximum likelihood method to fit the data to the logistic form of the dose-response relation, taking the volume effect into account by a power law. The analysis indicated that the incidence of radiation-related small-bowel compllications was higher after rectal surgery than after other types of surgery, which might be explained by the development of more adhesions. For both types of surgery a volume exponent of the power-law of 0.26 ± 0.05 was established. This means that if the small-bowel volume is increased by a factor of 2, the total dose has to be reduced by 17% for the same incidence of small-bowel complications. (author). 45 refs.; 6 figs.; 4 tabs

  10. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  11. Dose-response relation between physical activity and sick leave

    NARCIS (Netherlands)

    Proper, K.I.; Heuvel, S.G. van den; Vroome, E.M. de; Hildebrandt, V.H.; Beek, A.J. van der

    2006-01-01

    Objective: To investigate the dose-response relation between moderate and vigorous physical activity and sick leave in a working population. Methods: Data were used from three large Dutch databases: two continuous, cross sectional surveys among a representative sample of the Dutch population and one

  12. Population dose from nuclear medicine studies (DOMNES). Contribution of Project DOMNES to Dose Datemed2

    International Nuclear Information System (INIS)

    Ramirez, M. L.; Ruiz, A.; Ferrer, N.; Alonso Farto, J. C.; Alvarez, C.; Rodriguez, M.

    2013-01-01

    The DOMNES Project is created in 2001 to carry out a survey on nuclear medicine procedures used in the Spanish health centers, their frequency and the doses given to patients. In addition, it reports information to Dose Data Project Med 2, focusing on radiology exams. (Author)

  13. Radiation Dose Contribution To The Worker Health Level At Serpong Area

    International Nuclear Information System (INIS)

    Yuwono, Indro

    2000-01-01

    Analysis of internal and external radiation doses received for radiation and non-radiation workers of P2TBDU have been done. In the period of 1997/1998 and 1998/1999 there were no significant increasing level of radiation doses received that was 0.55 mSv and highest received radiation dose was 2.66% from dose limit value. Increasing of healthy difference on the same period was 5.76%. Increasing of healthy difference no cause by increasing of radiation dose received but maybe the food consumption design

  14. Pathological consequences of chronic low daily dose gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Seed, T.M.; Miller, A.C.; Ramakrishnan, N. [Armed Forces Radiobiology Research Inst., Bethesda, MD (United States); Fritz, T.E.

    2000-07-01

    The quantitative relationships between the chronic radiation exposure parameters of dose-rate and total dose in relation to associated health risks was examined in dogs. At a dose-rate of 75, 128, and 263 mGy/d the incidence of acute lymphohematopoietic suppression (aplastic anemia) and associated septic complications was 73%, 87%, and 100%, respectively, and it increased in dose-dependent manner. By contrast, at dose-rates below 75 mGy/d, late cancers contributed significantly to the death of relatively long-lived animals, whose mean survival time was 1800 days. Myeloproliferative disease (MPD), mainly myeloid leukemia, was the dominant pathology seen at the higher daily dose-rates (18.8-75 mGy/d). When daily exposure was carried out continuously, the incidence of MPD was quite high. It should be noted that the induction radiation-induced MPD in this study was highly significant, because spontaneous MPD is exceedingly rare in the dog. However, when the daily dose-rate was reduced further or exposure was discontinued, the incidence of MPD declined significantly. At these lower dose-rates, solid tumors contributed heavily to the life-shortening effects of chronic irradiation. The induction and progression of these survival-compromising, late forms of pathology appeared to be driven by the degree of hematopoietic suppression that occurred early during the exposure phase, and in turn by the capacity of hematopoietic system to repair itself, recover, and to accommodate under chronic radiation stress. (K.H.)

  15. Relative implications of protective responses versus damage induction at low dose and low-dose-rate exposures, using the microdose approach

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E

    2003-07-01

    In reviewing tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdose hits in exposed micromasses for a given radiation quality. DNA damage increases with the number of microdose hits. They also can induce adaptive protection, mainly against endogenous DNA damage. This protection involves cellular defenses, DNA repair and damage removal. With increasing numbers of low linear energy transfer (LET) microdose hits in exposed micromasses, adaptive protection first tends to outweigh damage and then (above 200 mGy) fails and largely disappears. These experimental data predict that cancer risk coefficients derived by epidemiology at high-dose irradiation decline at low doses and dose rates when adaptive protection outdoes DNA damage. The dose-risk function should include both linear and non-linear terms at low doses. (author)

  16. Relative implications of protective responses versus damage induction at low dose and low-dose-rate exposures, using the microdose approach

    International Nuclear Information System (INIS)

    Feinendegen, L.E.

    2003-01-01

    In reviewing tissue effects of low-dose radiation (1) absorbed dose to tissue is replaced by the sum of energy deposited with track events in cell-equivalent tissue micromasses, i.e. with microdose hits, in the number of exposed micromasses and (2) induced cell damage and adaptive protection are related to microdose hits in exposed micromasses for a given radiation quality. DNA damage increases with the number of microdose hits. They also can induce adaptive protection, mainly against endogenous DNA damage. This protection involves cellular defenses, DNA repair and damage removal. With increasing numbers of low linear energy transfer (LET) microdose hits in exposed micromasses, adaptive protection first tends to outweigh damage and then (above 200 mGy) fails and largely disappears. These experimental data predict that cancer risk coefficients derived by epidemiology at high-dose irradiation decline at low doses and dose rates when adaptive protection outdoes DNA damage. The dose-risk function should include both linear and non-linear terms at low doses. (author)

  17. Time and dose-related changes in the thickness of pig skin after irradiation with single doses of 90Sr/90Y β-rays

    International Nuclear Information System (INIS)

    Rezvani, M.; Hamlet, R.; Hopewell, J.W.; Sieber, V.K.

    1994-01-01

    Time-related changes in pig skin thickness have been evaluated using a non-invasive ultrasound technique after exposure to a range of single doses of 90 Sr/ 90 Yr β-rays. The reduction in relative skin thickness developed in two distinct phases: the first was between 12 and 20 weeks postirradiation. No further changes were then seen until 52 weeks postirradiation when a second phase of skin thinning was observed. This was complete after 76 weeks and no further changes in relative skin thickness were seen in the maximum follow up period of 129 weeks. The timings of these phases of damage were independent of the radiation dose, however, the severity of both phases of radiation-induced skin thinning were dose related. (Author)

  18. Dose-related gene expression changes in forebrain following acute, low-level chlorpyrifos exposure in neonatal rats

    International Nuclear Information System (INIS)

    Ray, Anamika; Liu Jing; Ayoubi, Patricia; Pope, Carey

    2010-01-01

    Chlorpyrifos (CPF) is a widely used organophosphorus insecticide (OP) and putative developmental neurotoxicant in humans. The acute toxicity of CPF is elicited by acetylcholinesterase (AChE) inhibition. We characterized dose-related (0.1, 0.5, 1 and 2 mg/kg) gene expression profiles and changes in cell signaling pathways 24 h following acute CPF exposure in 7-day-old rats. Microarray experiments indicated that approximately 9% of the 44,000 genes were differentially expressed following either one of the four CPF dosages studied (546, 505, 522, and 3,066 genes with 0.1, 0.5, 1.0 and 2.0 mg/kg CPF). Genes were grouped according to dose-related expression patterns using K-means clustering while gene networks and canonical pathways were evaluated using Ingenuity Pathway Analysis (registered) . Twenty clusters were identified and differential expression of selected genes was verified by RT-PCR. The four largest clusters (each containing from 276 to 905 genes) constituted over 50% of all differentially expressed genes and exhibited up-regulation following exposure to the highest dosage (2 mg/kg CPF). The total number of gene networks affected by CPF also rose sharply with the highest dosage of CPF (18, 16, 18 and 50 with 0.1, 0.5, 1 and 2 mg/kg CPF). Forebrain cholinesterase (ChE) activity was significantly reduced (26%) only in the highest dosage group. Based on magnitude of dose-related changes in differentially expressed genes, relative numbers of gene clusters and signaling networks affected, and forebrain ChE inhibition only at 2 mg/kg CPF, we focused subsequent analyses on this treatment group. Six canonical pathways were identified that were significantly affected by 2 mg/kg CPF (MAPK, oxidative stress, NFΚB, mitochondrial dysfunction, arylhydrocarbon receptor and adrenergic receptor signaling). Evaluation of different cellular functions of the differentially expressed genes suggested changes related to olfactory receptors, cell adhesion/migration, synapse

  19. Quantitative model of evaluation of the contribution of each radioactive source in the individual external dose Hx in nuclear medicine service personnel; Modelo quantitativo de avaliacao da contribuicao de cada fonte radioativa na dose individual externa Hx em trabalhador de servico de medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Nathalie Canhameiro; Tinois, Eduardo; Koga, Katia Hiromoto; Bezerra, Aline da Silva; Ferreira, Vinicius Capistrano; Azevedo, Thaisa Resende; Moriguchi, Sonia Marta, E-mail: soniamoriguchi@fmb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2016-07-01

    Assess whether the activities performed in the Nuclear Medicine service are significant in the total dose received by the workers and their relative contributions. Methods: measured independent variables: number of scintigraphies remaining in the examination room (N); eluted activity (E); Total activity marked in pharmaceuticals kits (K); num-ber of times that was scheduled to work in the Hot room (Q); Variable dependent measured: cumulative effective dose in the period 10/2012 to 04/2013 added to each worker, obtained by information registered daily and monthly on activities and doses received in the period. Held Multiple Linear Regression (D = a + β{sub 1} N + E + β{sub 2} β{sub 3} K + β{sub 4} Q) with α = 0.05 significance level. It was concluded that the independent variables N (p = 0.097) and E (p = 0.086) did not significantly interfere with the Cumulative dose in the period. The K variables (p = 0.017) and Q (p = 0.028) were significant in the proposed model. (author)

  20. Health effects of low doses at low dose rates: dose-response relationship modeling in a cohort of workers of the nuclear industry

    International Nuclear Information System (INIS)

    Metz-Flamant, Camille

    2011-01-01

    The aim of this thesis is to contribute to a better understanding of the health effects of chronic external low doses of ionising radiation. This work is based on the French cohort of CEA-AREVA NC nuclear workers. The mains stages of this thesis were (1) conducting a review of epidemiological studies on nuclear workers, (2) completing the database and performing a descriptive analysis of the cohort, (3) quantifying risk by different statistical methods and (4) modelling the exposure-time-risk relationship. The cohort includes monitored workers employed more than one year between 1950 and 1994 at CEA or AREVA NC companies. Individual annual external exposure, history of work, vital status and causes of death were reconstructed for each worker. Standardized mortality ratios using French national mortality rates as external reference were computed. Exposure-risk analysis was conducted in the cohort using the linear excess relative risk model, based on both Poisson regression and Cox model. Time dependent modifying factors were investigated by adding an interaction term in the model or by using exposure time windows. The cohort includes 36, 769 workers, followed-up until age 60 in average. During the 1968- 2004 period, 5, 443 deaths, 2, 213 cancers, 62 leukemia and 1, 314 cardiovascular diseases were recorded. Among the 57% exposed workers, the mean cumulative dose was 21.5 milli-sieverts (mSv). A strong Healthy Worker Effect is observed in the cohort. Significant elevated risks of pleura cancer and melanoma deaths were observed in the cohort but not associated with dose. No significant association was observed with solid cancers, lung cancer and cardiovascular diseases. A significant dose-response relationship was observed for leukemia excluding chronic lymphatic leukemia, mainly for doses received less than 15 years before and for yearly dose rates higher than 10 mSv. This PhD work contributes to the evaluation of risks associated to chronic external radiation

  1. Dose titration to reduce dipyridamole-related headache.

    Science.gov (United States)

    Chang, Yeu-Jhy; Ryu, Shan-Jin; Lee, Tsong-Hai

    2006-01-01

    Combination of low-dose aspirin and modified-release dipyridamole (ASA+MR-DP) provides a significantly increased benefit in stroke prevention over aspirin alone. However, headaches were reported in more patients receiving dipyridamole-containing agents than in those receiving placebo. We undertook a randomized, double-blind, placebo-controlled trial to evaluate which dosing regimens of ASA+MR-DP have better tolerance. This trial randomized 146 patients with a history of ischemic cerebrovascular disease into three groups: placebo (days 1-28), reduced dose (placebo on days 1-4, ASA+MR-DP once daily before bed during days 5-14, and b.i.d. on days 15-28), and regular dose (placebo on days 1-4, and ASA+MR-DP b.i.d. on days 5-28). Using Chinese diary card, headache was assessed as mean cumulated headache (Sigma frequency x intensity/occurrence days x study days) over the study period, and was graded 0-4 according to Cancer Therapy Evaluation Program, Common Toxicity Criteria, Version 2.0. Intent-to-treat patients after randomization was 46 in placebo group, 45, reduced dose, and 49, regular dose. Among commonly reported adverse effects, headache of any grade occurred significantly more in the regular dose group (38.8%), as compared to the other two groups (p < 0.05). Mean cumulated headache was higher (p < 0.05) in the regular dose group than in the reduced group during days 5-14. Of 27 patients who dropped out, 15 (55.6%) were due to headache, which was substantially more in regular dose (8, 53.3%), though the difference was statistically insignificant. Initial reduced dose treatment with ASA+MR-DP may cause fewer headaches than regular dosing, and seems better tolerated by those susceptible to phosphodiesterase inhibitor-induced headache. Copyright 2006 S. Karger AG, Basel.

  2. Three-Week Bright-Light Intervention Has Dose-Related Effects on Threat-Related Corticolimbic Reactivity and Functional Coupling

    DEFF Research Database (Denmark)

    Fisher, Patrick M; Madsen, Martin K; Mc Mahon, Brenda

    2014-01-01

    environmental stimuli (e.g., threat) and may underlie these effects. Serotonin signaling modulates this circuit and is implicated in the pathophysiology of seasonal and other affective disorders. METHODS: We evaluated the effects of a bright-light intervention protocol on threat-related corticolimbic reactivity......-related amygdala and prefrontal reactivity in a dose-dependent manner. Conversely, amygdala-prefrontal and intraprefrontal functional coupling increased significantly in a dose-dependent manner. Genotype status significantly moderated bright-light intervention effects on intraprefrontal functional coupling....... CONCLUSIONS: This is the first study to evaluate the effects of clinically relevant bright-light intervention on threat-related brain function. We show that amygdala-prefrontal reactivity and communication are significantly affected by bright-light intervention, an effect partly moderated by genotype...

  3. Investigation of Contributions of Cosmic Radiation to Background Dose with Altitude at Ahmadu Bello University, Zaria, Nigeria

    International Nuclear Information System (INIS)

    Uwaechia, F.C.; Zakari, Y.I.; Ibeanu, I.G.E.

    2014-01-01

    This study investigated the contributions of cosmic radiation to background dose at Ahmadu Bello University, Zaria, Nigeria using two portable survey meters (Rados -120 and FH 40F2 ). The work was conducted in two phases (dry and rainy seasons).The recorded gamma dose rates were observed to proportionally increase with increase in altitude, that is from ground floor (altitude 3.52 m above sea level) to the eight floor (altitude 30.08 m above sea level). In a similar manner, there were observed variations in the seasonal results-the dry season data were consistently higher than the rainy season data. The mean measured indoor and outdoor gamma dose rates for the two seasons (rainy and dry seasons) were 210.0nSv/h and 279.4nSv/h, and 231.3nSv/h and 368.8nSv/h at the ground floor and the eight floor, respectively. The rainy season result repeated itself on a particular very heavy rainy day with a mean measured gamma dose rate of 204.4nSv/h and 267.4nSv/h at the ground floor and eight floor, respectively. The annual indoor and outdoor mean effective dose for a 1000hour working period was calculated as 0.32 μSv and 0.35 μSv at the ground floor and 0.68 μSv and 0.76 μSv the 8 th floor, respectively (for inside and outside the building).

  4. Calculational methods for estimating skin dose from electrons in Co-60 gamma-ray beams

    International Nuclear Information System (INIS)

    Higgins, P.D.; Sibata, C.H.; Attix, F.H.; Paliwal, B.R.

    1983-01-01

    Several methods have been employed to calculate the relative contribution to skin dose due to scattered electrons in Co-60 gamma-ray beams. Either the Klein-Nishina differential scattering probability is employed to determine the number and initial energy of electrons scattered into the direction of a detector, or a Gaussian approximation is used to specify the surface distribution of initial pencil electron beams created by parallel or diverging photon fields. Results of these calculations are compared with experimental data. In addition, that fraction of relative surface dose resulting from photon interactions in air alone is estimated and compared with data extrapolated from measurements at large source-surface distance (SSD). The contribution to surface dose from electrons generated in air is 50% or more of the total skin dose for SSDs greater than 80 cm

  5. Calculational methods for estimating skin dose from electrons in Co-60 gamma-ray beams

    International Nuclear Information System (INIS)

    Higgins, P.D.; Sibata, C.H.; Attix, F.H.; Paliwal, B.R.

    1983-01-01

    Several methods have been employed to calculate the relative contribution to skin dose due to scattered electrons in Co-60 γ-ray beams. Either the Klein--Nishina differential scattering probability is employed to determine the number and initial energy of electrons scattered into the direction of a detector, or a Gaussian approximation is used to specify the surface distribution of initial pencil electron beams created by parallel or diverging photon fields. Results of these calculations are compared with experimental data. In addition, that fraction of relative surface dose resulting from photon interactions in air alone is estimated and compared with data extrapolated from measurements at large source--surface distance (SSD). The contribution to surface dose from electrons generated in air is 50% or more of the total skin dose for SSDs greater than 80 cm

  6. The minimum measurable dose of the sensitive Harshaw TLDs

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1991-01-01

    The TL-dose response was measured for the sensitive Harshaw manufactured phosphors (CaF 2 :Dy and CaF 2 :Tm), taking chips from the same batch and from different batches. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses were derived and compared to the minimum measurable dose calculated by taking 3 times the standard deviation of unirradiated chips. The contribution of the individual calibration of each TLD chip was checked, as well

  7. Concepts of collective dose in radiological protection

    International Nuclear Information System (INIS)

    Lindell, B.

    1985-01-01

    The collective dose (S) is the product of the number of individuals exposed and their average radiation dose. ''Radiation dose'' is usually taken to be the effective dose equivalent (Hsub(E)) as defined by the ICRP. The unit of the collective dose is then the man.sievert (man.Sv). The following four applications of the collective dose are the most common: (a) in the assessment of the highest per caput dose rate in the future from a continued practice which exposes some critical group or the population as a whole to radiation; (b) in the limitation of present radiation sources, if it is believed that additional sources in the future may add to the per caput dose in a population so that it might reach unacceptable levels unless all sources are controlled at an early stage; (c) as an input to justification assessments, indicating the total detriment from a certain practice; and (d) as an input to optimization assessments as the basis for costing detriment in differential cost-benefit analyses of protection arrangements. It is sometimes said that the collective dose is a useful quantity only if the assumption of a non-threshold, linear dose-response relation is valid. This assumption is not always necessary. Applications (a) and (b) are possible without any assumption on the dose-response relationship at very low doses. Only applications (c) and (d) require the assumption of a non-threshold, linear dose-response relation. Some hesitation in using the collective dose originates in distrust in the biological assumptions implied by uses (c) and (d), but also in lack of confidence in the meaningfulness of collective doses that have been derived by adding dose contributions over very long time periods. However, none of the four applications (a) - (d) is by necessity related to extreme time scales. That problem mainly arises in the assessment of radioactive waste repositories

  8. Analysing countries' contribution to climate change: scientific and policy-related choices

    International Nuclear Information System (INIS)

    Elzen, Michel den; Fuglestvedt, Jan; Hoehne, Niklas; Trudinger, Cathy; Lowe, Jason; Matthews, Ben; Romstad, Bard; Pires de Campos, Christiano; Andronova, Natalia

    2005-01-01

    This paper evaluates the influence of different policy-related and scientific choices on the calculated regional contributions to global climate change (the 'Brazilian Proposal'). Policy-related choices include the time period of emissions, the mix of greenhouse gases and different indicators of climate change impacts. The scientific choices include historical emissions and model representations of the climate system. We generated and compared results of several simple climate models. We find that the relative contributions of different nations to global climate change-from emissions of greenhouse gases alone-are quite robust, despite the varying model complexity and differences in calculated absolute changes. For the default calculations, the average calculated contributions to the global mean surface temperature increase in 2000 are about 40% from OECD, 14% from Eastern Europe and Former Soviet Union, 24% from Asia and 22% from Africa and Latin America. Policy-related choices, such as time period of emissions, climate change indicator and gas mix generally have larger influence on the results than scientific choices. More specifically, choosing a later attribution start date (1990 instead of 1890) for historical emissions, decreases the contributions of regions that started emitting early, such as the OECD countries by 6 percentage points, whereas it increases the contribution of late emitters such as Asia by 8 percentage points. However, only including the fossil CO 2 emissions instead of the emissions of all Kyoto gases (fossil and land use change), increases the OECD contributions by 21 percentage points and decreases the contribution of Asia by 14 percentage points

  9. Dose due to 40K

    International Nuclear Information System (INIS)

    Escareno J, E.; Vega C, H. R.

    2011-10-01

    The dose due to 40 K has been estimated. Potassium is one of the most abundant elements in nature, being approximately 2% of the Earth's crust. Potassium has three isotopes 39 K, 40 K and 41 K, two are stable while 40 K is radioactive with a half life of 1.2x10 9 years; there is 0.0117% 40 K-to-K ratio. Potassium plays an important role in plants, animals and humans growth and reproduction. Due to the fact that K is an essential element for humans, 40 K is the most abundant radioisotope in human body. In order to keep good health conditions K must be intake at daily basis trough food and beverages, however when K in ingested above the requirements produce adverse health effects in persons with renal, cardiac and hypertension problems or suffering diabetes. In 89.3% 40 K decays to 40 C through β-decay, in 10.3% decays through electronic capture and emitting 1.46 MeV γ-ray. K is abundant in soil, construction materials, sand thus γ-rays produced during 40 K decay contribute to external dose. For K in the body practically all 40 K decaying energy is absorbed by the body; thus 40 K contributes to total dose in humans and it is important to evaluate its contribution. In this work a set of 40 K sources were prepared using different amounts of KCl salt, a γ-ray spectrometer with a NaI(Tl) was characterized to standardized the sources in order to evaluate the dose due to 40 K. Using thermoluminescent dosemeters the dose due to 40 K was measured and related to the amount of 40 K γ-ray activity. (Author)

  10. Paediatric urological investigations - dose comparison between urology-related and CT irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Page, Mark; Florescu, Cosmin [Southern Health, Diagnostic Imaging, Melbourne (Australia); Johnstone, Lilian [Monash Children' s Hospital, Department of Paediatrics, Melbourne (Australia); Habteslassie, Daniel [Monash University, Department of Medicine, Melbourne (Australia); Ditchfield, Michael [Southern Health, Diagnostic Imaging, Melbourne (Australia); Monash Children' s Hospital, Diagnostic Imaging, Melbourne (Australia); Monash University, Department of Medicine, Melbourne (Australia)

    2013-07-15

    Urological investigation in children frequently involves high radiation doses; however, the issue of radiation for these investigations receives little attention compared with CT. To compare the radiation dose from paediatric urological investigations with CT, which is commonly regarded as the more major source of radiation exposure. We conducted a retrospective audit in a tertiary paediatric centre of the number and radiation dose of CT scans, micturating cystourethrography exams and urological nuclear medicine scans from 2006 to 2011. This was compared with radiation doses in the literature and an audit of the frequency of these studies in Australia. The tertiary centre audit demonstrated that the ratio of the frequency of urological to CT examinations was 0.8:1 in children younger than 17 years. The ratio of the radiation dose of urological to CT examinations was 0.7:1. The ratio in children younger than 5 years was 1.9:1. In Australia the frequency of urological procedures compared with CT was 0.4:1 in children younger than 17 years and 3.1:1 in those younger than 5 years. The ratio of radiation-related publications was 1:9 favouring CT. The incidence and radiation dose of paediatric urological studies is comparable to those of CT. Nevertheless the radiation dose of urological procedures receives considerably less attention in the literature. (orig.)

  11. Low-Dose, Ionizing Radiation and Age-Related Changes in Skeletal Microarchitecture

    Directory of Open Access Journals (Sweden)

    Joshua S. Alwood

    2012-01-01

    Full Text Available Osteoporosis can profoundly affect the aged as a consequence of progressive bone loss; high-dose ionizing radiation can cause similar changes, although less is known about lower doses (≤100 cGy. We hypothesized that exposure to relatively low doses of gamma radiation accelerates structural changes characteristic of skeletal aging. Mice (C57BL/6J-10 wk old, male were irradiated (total body; 0-sham, 1, 10 or 100 cGy 137Cs and tissues harvested on the day of irradiation, 1 or 4 months later. Microcomputed tomography was used to quantify microarchitecture of high turnover, cancellous bone. Irradiation at 100 cGy caused transient microarchitectural changes over one month that were only evident at longer times in controls (4 months. Ex vivo bone cell differentiation from the marrow was unaffected by gamma radiation. In conclusion, acute ionizing gamma irradiation at 100 cGy (but not at 1 cGy or 10 cGy exacerbated microarchitectural changes normally found during progressive, postpubertal aging prior to the onset of age-related osteoporosis.

  12. Relative source contributions for perchlorate exposures in a lactating human cohort

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, Andrea B. [University of North Texas Health Sciences Center (United States); Dyke, Jason V. [University of Texas at Arlington (United States); Ohira, Shin-Ichi [Kumamoto University (Japan); Dasgupta, Purnendu K., E-mail: Dasgupta@uta.edu [University of Texas at Arlington (United States)

    2013-01-15

    Perchlorate is an iodine-uptake inhibitor and common contaminant of food and drinking water. Understanding the amount of perchlorate exposure occurring through non-water sources is essential for accurate estimates of human exposure levels, and establishment of drinking water limits for this pervasive contaminant. The study objective was to determine the amount of perchlorate intake derived from diet rather than water. Subjects provided drinking water samples, detailed fluid-intake records, 24 h urine collections and four milk samples for nine days. Samples were analyzed for perchlorate by isotope dilution ion chromatography–tandem mass spectrometry. Amounts of perchlorate derived from drinking water and dietary sources were calculated for each individual. Water of local origin was found to contribute a minor fraction of perchlorate intake. Estimated fraction intake from drinking water ranged from 0 to 36%. The mean and median dose of perchlorate derived from non-water sources by lactating women was 0.18 μg/kg/day (range: 0.06 to 0.36 μg/kg/day.) Lactating women consumed more fluid (mean 2.424 L/day) than has been assumed in recent risk assessments for perchlorate. The data reported here indicate that lactating women may be exposed to perchlorate through dietary sources at markedly higher levels than estimated previously. Exposures to perchlorate from non-water sources may be higher than recent estimates, including those used to develop drinking water standards. - Highlights: ► Residence in an area with perchlorate-contaminated water may be a poor predictor of exposure. ► Exposures to perchlorate from food are likely underestimated. ► The relative contributions for human perchlorate exposures should be weighted more heavily towards non-water sources.

  13. Short-term, high-dose glucocorticoid treatment does not contribute to reduced bone mineral density in patients with multiple sclerosis

    DEFF Research Database (Denmark)

    Olsson, A.; Oturai, D B; Sørensen, P S

    2015-01-01

    BACKGROUND: Patients with multiple sclerosis (MS) are at increased risk of reduced bone mineral density (BMD). A contributing factor might be treatment with high-dose glucocorticoids (GCs). OBJECTIVES: The objective of this paper is to assess bone mass in patients with MS and evaluate...... the importance of short-term, high-dose GC treatment and other risk factors that affect BMD in patients with MS. METHODS: A total of 260 patients with MS received short-term high-dose GC treatment and had their BMD measured by dual x-ray absorptiometry. BMD was compared to a healthy age-matched reference...... population (Z-scores). Data regarding GCs, age, body mass index (BMI), serum 25(OH)D, disease duration and severity were collected retrospectively and analysed in a multiple linear regression analysis to evaluate the association between each risk factor and BMD. RESULTS: Osteopenia was present in 38...

  14. Model of the contribution of the compton generated radiation to the dose rate for an experiment in a semi industrial irradiation plant

    International Nuclear Information System (INIS)

    Mangussi, Josefina

    2007-01-01

    The model of the build up contribution to the absorbed dose rate in a semi industrial irradiation plant is presented. A static irradiation of a lucite phantom with and without water is modeled. The absorbed dose was measured with silver and potassium dichromate dosemeters. Two approximations are used, the first one is a global adjustment of the attenuation coefficient and the second one consists in a detailed description of the Compton scattering. A specific numerical model is developed for each approximation and the absorbed dose rates calculated are compared with the experimental measurements. The achievements and limitations of both models are discussed. (author) [es

  15. Consequences of the exposure at low dose rates-contribution of animal experimentation. Consequences de l'exposition aux faibles debits de dose. Apport de l'experimentation animale

    Energy Technology Data Exchange (ETDEWEB)

    Masse, R. (CEA Centre d' Etudes de Fontenay-aux-Roses, 92 (FR). Direction des Sciences du Vivant)

    1990-01-01

    The exposure of laboratory animals to the various types of radiations will induce cancers in relation with the tissue absorbed doses. The shape of the dose-effet relationship is most variable. It is important to distinguish which tumours are comparable to human tumours. Those showing more analogies answer but seldom to the classical lineo-quadratic relationship; however, a strong attenuation of induction is demonstrated at low dose rates. Quasi-threshold relationships are seen after the exposure of some tissues to high-LET radiations. These observations question the validity of generalizing the radiobiologists' dual action theory, setting the origin of the dose-effect relationship in the induction of events within the DNA molecule. There is an alternative in the cellular collaboration events; it assumes that the effectiveness per dose unit decreases constantly as an inverse function of the dose rate.

  16. Advanced Computational Approaches for Characterizing Stochastic Cellular Responses to Low Dose, Low Dose Rate Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Bobby, R., Ph.D.

    2003-06-27

    -LET radiation). Such phantom risks also may arise from risk assessments conducted for combined exposure to low- and high-LET radiations when based on the LNT or other models that exclude RR < 1. Our results for high-LET radiation are consistent with the LNT hypothesis but only where there is no additional low-LET contribution (e.g., gamma rays) to the total dose. For high-LET neutron sources, gamma rays arise (especially in vivo) for large mammals such as humans from neutron interactions with tissue. The gamma rays might provide some protection from low-dose-related stochastic effects via inducing the protective bystander apoptosis effect that is considered to contribute to tissue cleansing via removal of problematic cells.

  17. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  18. Relative contributions of individual, institutional and system factors ...

    African Journals Online (AJOL)

    This study investigated the relative contributions of individual, institutional and system factors to utilisation of Research4Life databases by scientists in the National Agricultural Research Institutes (NARIs) in Nigeria. The study adopted the descriptive survey research design of the correlational type. Simple and stratified ...

  19. The Contribution of Tissue Level Organization to Genomic Stability Following Low Dose/Low Dose Rate Gamma and Proton Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Cheryl G. Burrell, Ph.D.

    2012-05-14

    The formation of functional tissue units is necessary in maintaining homeostasis within living systems, with individual cells contributing to these functional units through their three-dimensional organization with integrin and adhesion proteins to form a complex extra-cellular matrix (ECM). This is of particular importance in those tissues susceptible to radiation-induced tumor formation, such as epithelial glands. The assembly of epithelial cells of the thyroid is critical to their normal receipt of, and response to, incoming signals. Traditional tissue culture and live animals present significant challenges to radiation exposure and continuous sampling, however, the production of bioreactor-engineered tissues aims to bridge this gap by improve capabilities in continuous sampling from the same functional tissue, thereby increasing the ability to extrapolate changes induced by radiation to animals and humans in vivo. Our study proposes that the level of tissue organization will affect the induction and persistence of low dose radiation-induced genomic instability. Rat thyroid cells, grown in vitro as 3D tissue analogs in bioreactors and as 2D flask grown cultures were exposed to acute low dose (1, 5, 10 and 200 cGy) gamma rays. To assess immediate (6 hours) and delayed (up to 30 days) responses post-irradiation, various biological endpoints were studied including cytogenetic analyses, apoptosis analysis and cell viability/cytotoxicity analyses. Data assessing caspase 3/7 activity levels show that, this activity varies with time post radiation and that, overall, 3D cultures display more genomic instability (as shown by the lower levels of apoptosis over time) when compared to the 2D cultures. Variation in cell viability levels were only observed at the intermediate and late time points post radiation. Extensive analysis of chromosomal aberrations will give further insight on the whether the level of tissue organization influences genomic instability patterns after

  20. Time and dose-related changes in the thickness of pig skin after irradiation with single doses of [sup 90]Sr/[sup 90]Y [beta]-rays

    Energy Technology Data Exchange (ETDEWEB)

    Rezvani, M.; Hamlet, R.; Hopewell, J.W.; Sieber, V.K. (Churchill Hospital, Oxford (United Kingdom))

    1994-04-01

    Time-related changes in pig skin thickness have been evaluated using a non-invasive ultrasound technique after exposure to a range of single doses of [sup 90]Sr/[sup 90]Yr [beta]-rays. The reduction in relative skin thickness developed in two distinct phases: the first was between 12 and 20 weeks postirradiation. No further changes were then seen until 52 weeks postirradiation when a second phase of skin thinning was observed. This was complete after 76 weeks and no further changes in relative skin thickness were seen in the maximum follow up period of 129 weeks. The timings of these phases of damage were independent of the radiation dose, however, the severity of both phases of radiation-induced skin thinning were dose related. (Author).

  1. Ground-water contribution to dose from past Hanford Operations

    International Nuclear Information System (INIS)

    Freshley, M.D.; Thorne, P.D.

    1992-08-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project is being conducted to estimate radiation doses that populations and individuals could have received from Hanford Site operations from 1944 to the present. Four possible pathways by which radionuclides migrating in ground water on the Hanford Site could have reached the public have been identified: (1) through contaminated ground water migrating to the Columbia River; (2) through wells on or adjacent to the Hanford Site; (3) through wells next to the Columbia River downstream of Hanford that draw some or all of their water from the river (riparian wells); and (4) through atmospheric deposition resulting in contamination of a small watershed that, in turn, results in contamination of a shallow well or spring by transport in the ground water. These four pathways make up the ''ground-water pathway,'' which is the subject of this study. Assessment of the ground-water pathway was performed by (1) reviewing the existing extensive literature on ground water and ground-water monitoring at Hanford and (2) performing calculations to estimate radionuclide concentrations where no monitoring data were collected. Radiation doses that would result from exposure to these radionuclides were calculated

  2. Occupational dose trends in Tanzania

    International Nuclear Information System (INIS)

    Muhogora, W.E.; Nyanda, A.M.; Ngaile, J.E.; Lema, U.S.

    1998-01-01

    This paper describes the present status of occupational radiation exposure of monitored workers in Tanzania from 1986 to 1997. The analysis of dose records observes over this period, a fluctuating trend both in the individual and collective doses. The trend is more related to the fluctuations of the number of radiation workers than to the possible radiation safety changes of the working conditions. It has been found that, the maximum annual dose for the worker in all work categories was about 18 mSv y -1 . This suggests that the occupational radiation exposure in all practices satisfies the current dose limitation system. The national exposure summary shows that, the highest collective dose of 12.8 man-Sv which is 90% of the total collective dose, was due to medical applications. The applications in industry and research had a contribution of nearly 0.8 and 0.7 man-Sv respectively. From the professional point of view, the medical diagnostic radiographers received the highest collective dose of 11.2 man-Sv. Although the medical physicists recorded the minimum collective dose of nearly 0.07 man-Sv, the data shows that this profession received the highest mean dose of about 33 mSv in 12 years. Some achievements of the personnel monitoring services and suggestions for future improvement are pointed out. (author)

  3. The effectiveness of small doses of ionizing radiations for the induction of cell reproductive death, chromosomal changes and malignant transformation

    International Nuclear Information System (INIS)

    Barendsen, G.W.

    1976-01-01

    For reproductive death of mammalian cells, accumulation of damage induced by two or more particles is frequently predominant at doses of X-rays or γ-rays in excess of 500 rad. For doses of less than 100 rad of X-rays, damage due to single particles generally provides the largest contribution to cell lethality, but the relative effectiveness depends strongly on the type of cell investigated and on the conditions of exposure and environment. In addition, a marked dependence on LET is observed. For LET values at which the relative contribution of accumulation of damage has become negligible, a significant influence of dose-modifying factors such as the presence of oxygen may still be evident. This implies that 'single particle damage' is not necessarily independent of modifying factors. A similar conclusion can be derived from data on some types of micro-organisms. For the induction of chromosome aberrations, published data show that the relative contributions of the two types of mechanisms mentioned, may depend on the type of aberration studied. For tumor induction the relative contributions of the two mechanisms cannot in general be derived from incidence versus dose relations because of the influence of promoting, permitting and inhibiting conditions and the influence of cell reproductive death

  4. Dose due to {sup 40}K

    Energy Technology Data Exchange (ETDEWEB)

    Escareno J, E.; Vega C, H. R., E-mail: edmundoej@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2011-10-15

    The dose due to {sup 40}K has been estimated. Potassium is one of the most abundant elements in nature, being approximately 2% of the Earth's crust. Potassium has three isotopes {sup 39}K, {sup 40}K and {sup 41}K, two are stable while {sup 40}K is radioactive with a half life of 1.2x10{sup 9} years; there is 0.0117% {sup 40}K-to-K ratio. Potassium plays an important role in plants, animals and humans growth and reproduction. Due to the fact that K is an essential element for humans, {sup 40}K is the most abundant radioisotope in human body. In order to keep good health conditions K must be intake at daily basis trough food and beverages, however when K in ingested above the requirements produce adverse health effects in persons with renal, cardiac and hypertension problems or suffering diabetes. In 89.3% {sup 40}K decays to {sup 40}C through {beta}-decay, in 10.3% decays through electronic capture and emitting 1.46 MeV {gamma}-ray. K is abundant in soil, construction materials, sand thus {gamma}-rays produced during {sup 40}K decay contribute to external dose. For K in the body practically all {sup 40}K decaying energy is absorbed by the body; thus {sup 40}K contributes to total dose in humans and it is important to evaluate its contribution. In this work a set of {sup 40}K sources were prepared using different amounts of KCl salt, a {gamma}-ray spectrometer with a NaI(Tl) was characterized to standardized the sources in order to evaluate the dose due to {sup 40}K. Using thermoluminescent dosemeters the dose due to {sup 40}K was measured and related to the amount of {sup 40}K {gamma}-ray activity. (Author)

  5. Effect of edema, relative biological effectiveness, and dose heterogeneity on prostate brachytherapy

    International Nuclear Information System (INIS)

    Wang, Jian Z.; Mayr, Nina A.; Nag, Subir; Montebello, Joseph; Gupta, Nilendu; Samsami, Nina; Kanellitsas, Christos

    2006-01-01

    Many factors influence response in low-dose-rate (LDR) brachytherapy of prostate cancer. Among them, edema, relative biological effectiveness (RBE), and dose heterogeneity have not been fully modeled previously. In this work, the generalized linear-quadratic (LQ) model, extended to account for the effects of edema, RBE, and dose heterogeneity, was used to assess these factors and their combination effect. Published clinical data have shown that prostate edema after seed implant has a magnitude (ratio of post- to preimplant volume) of 1.3-2.0 and resolves exponentially with a half-life of 4-25 days over the duration of the implant dose delivery. Based on these parameters and a representative dose-volume histogram (DVH), we investigated the influence of edema on the implant dose distribution. The LQ parameters (α=0.15 Gy -1 and α/β=3.1 Gy) determined in earlier studies were used to calculate the equivalent uniform dose in 2 Gy fractions (EUD 2 ) with respect to three effects: edema, RBE, and dose heterogeneity for 125 I and 103 Pd implants. The EUD 2 analysis shows a negative effect of edema and dose heterogeneity on tumor cell killing because the prostate edema degrades the dose coverage to tumor target. For the representative DVH, the V 100 (volume covered by 100% of prescription dose) decreases from 93% to 91% and 86%, and the D 90 (dose covering 90% of target volume) decrease from 107% to 102% and 94% of prescription dose for 125 I and 103 Pd implants, respectively. Conversely, the RBE effect of LDR brachytherapy [versus external-beam radiotherapy (EBRT) and high-dose-rate (HDR) brachytherapy] enhances dose effect on tumor cell kill. In order to balance the negative effects of edema and dose heterogeneity, the RBE of prostate brachytherapy was determined to be approximately 1.2-1.4 for 125 I and 1.3-1.6 for 103 Pd implants. These RBE values are consistent with the RBE data published in the literature. These results may explain why in earlier modeling studies

  6. The relative contributions of climatic elements and environmental ...

    African Journals Online (AJOL)

    The aim of this paper was to determine the relative contributions of climatic elements and environmental factors to urban flooding in Awka urban area of Anambra State. Towards achieving this aim, 10 year (2000-2009) meteorological data of temperature and rainfall of the study area were collected from synoptic ...

  7. Population doses in Spain. Contribution of the project dopoes a dose Datamed 2

    International Nuclear Information System (INIS)

    Ruiz Cruces, R.; Canete Hidalgo, S.; Perez Martinez, M.; Pola, A.; Moreno, S.; Rodriguez, M.; Alvarez, C.; Gil, M.

    2013-01-01

    Frequency and effective dose values are of the order of the reported in the publication Radiation Protection 154 by neighbouring countries. Spain participated actively in the project DDM2 by sending all the required information and this has served test to ensure the correct development of the DOPOES project, which is ongoing. (Author)

  8. Relative dose efficiencies of antiscatter grids and air gaps in pediatric radiography

    International Nuclear Information System (INIS)

    McDaniel, D.L.; Cohen, G.; Wagner, L.K.; Robinson, L.H.

    1984-01-01

    The relative dose efficiencies (RDE) of various antiscatter grids and air gaps were determined for conditions simulating those found in pediatric radiography, using phantoms representing a newborn child, a 5-yr-old and a 10-yr-old child. Our data indicate than an air gap is best for the newborn, due to the low levels of scatter. The 8:1 fiber grid or 15.2-cm air gap without a grid can improve dose efficiency (DE) for the 5-yr-old child by 20%--25% relative to the 3.3-cm air gap and no-grid technique, while for the 10-yr-old child, DE can be improved by 40% with an 8:1 fiber grid

  9. Identification and analysis of main radionuclides that potentially contribute to the internal dose for workers at radiopharmacy facilities

    International Nuclear Information System (INIS)

    Sanches, Matias Puga

    2004-01-01

    The optimization principle in radiation protection means that there is a reasonable balance between resources used to monitor exposures and the benefits due to the monitoring program. Programs for the monitoring of workers handling radioactive materials are influenced by numerous factors. Estimation of internal doses due to inhalation or ingestion of radioactive materials is often based on measurements of the activity in the tissues of the body and in excreta, following a given intake. In order to enable dose estimations using the biokinetic models recommended by the ICRP and laboratory data, it is proposed to carry out comprehensive study to identify the main radionuclides that potentially contribute to the internal dose of workers at radiopharmacy facilities. The applied methodology for identification of these radionuclides takes into account criteria set out by the ICRP and IAEA. The practical purpose to set up this study was to establish a consistent approach to ensure that the dose assessments are as simple as possible and guarantee the necessary quality standards. The result of this study has indicated the requirement of routine measurements for seven radionuclides over all range of radioactive material compounds, handled at the radiopharmacy plant of IPEN, avoiding unjustifiable work concerning activity levels that are not relevant for the health of the occupationally exposed persons. The main intake pathways, the appropriate monitoring frequencies and derived reference level have also been identified. (author)

  10. The real-world dose-relativity of sevelamer hydrochloride and lanthanum carbonate monotherapy in patients with end-stage renal disease.

    Science.gov (United States)

    Wilson, Rosamund J; Keith, Michael S; Preston, Peter; Copley, J Brian

    2013-12-01

    Sevelamer hydrochloride (SH) and lanthanum carbonate (LC) are calcium-free phosphate binders used for the management of hyperphosphatemia in patients with end-stage renal disease (ESRD). The objective of this analysis was to evaluate the real-world dose-relativity between SH and LC monotherapy in US patients with ESRD. This was a post hoc analysis of a 16-week, real-world study (Vemuri et al. in BMC Nephrol 12:49, 2011) of the efficacy of conversion to LC monotherapy from other phosphate binders. The SH:LC dose-relativity ratio, based on the mean daily dose, was calculated in the subset of patients from the Vemuri study who converted from SH to LC monotherapy and had available SH and LC dose data. A total of 950 patients converted from SH to LC monotherapy and had recorded dose data. The post hoc analysis population comprised 691 patients with available dose data for both SH at baseline and LC at week 16. The mean (SD) serum phosphate level at baseline was 5.91 (1.66) mg/dL. After conversion to LC monotherapy for 16 weeks, the mean (SD) serum phosphate level was 5.93 (1.85) mg/dL. The mean (SD) daily baseline SH dose was 7,703 (3,642) mg and the mean (SD) daily LC dose at week 16 was 2,800 (939) mg (9.6 versus 2.8 tablets, respectively; P relativity ratio of 2.8. The median individual patient SH:LC dose-relativity ratio was 2.6 (95% CI 2.6-2.8). Across baseline SH dose subgroups (2,400-4,800, >4,800-7,200, >7,200-9,600, and >9,600 mg/day), the mean daily SH dose was 4,051, 7,047, 9,253, and 13,150 mg, respectively. In comparison, the mean daily LC dose was 2,445-3,156 mg. Thus, patients requiring baseline SH doses >7,200 mg/day (41% of the analysis population) had higher SH:LC dose-relativity ratios of 3.1-4.2 (median individual patient ratios 3.1-4.0). In this post hoc analysis of real-world dose-relativity, the overall SH:LC dose-relativity ratio was 2.8 (median individual patient ratio 2.6 (95% CI 2.6-2.8). These findings are consistent with the World Health

  11. Job-related mortality risks of Hanford workers and their relation to cancer effects of measured doses of external radiation

    International Nuclear Information System (INIS)

    Kneale, G.W.; Mancuso, T.F.; Stewart, A.M.

    1983-01-01

    If we exclude all persons who were classified as clerical workers we find that over 40% of the Hanford workers had either professional or technical qualifications (professional workers). The ratio of professional to manual workers was equally high for safe and dangerous occupations but during the period 1944-77 professional workers who were doing the most dangerous work had too many deaths by comparison with other persons with similar qualifications, and manual workers doing equally dangerous work had too few deaths by comparison with other manual workers. In practice, this means that in any analysis of dose-related cancer risks of Hanford workers it is essential to control for job-related mortality risks as well as all the usual factors such as sex, dates of birth and hire and duration of employment. The results of including all these factors in a cohort analysis of Hanford data by the method of regression models in life tables are described and also the reasons why it was concluded that the risk per unit dose is increased at low dose levels (i.e. the dose-response curve is curvilinear downwards). (author)

  12. The biological bases of the dose-effect relationship; Les bases biologiques de la relation dose-effet

    Energy Technology Data Exchange (ETDEWEB)

    Lafuma, J

    2001-06-01

    In radiation protection, the recent data in epidemiology, in animal experimentation and on the base researches are no more compatible with a linear dose-effect relationship without threshold and do not account for the radiological risks at low doses. The cancers should be accelerated by radiations as any pathology linked to the ageing and for which threshold exit. Relative to the genetic risk it is known today that the natural exposure that lasts for several generations has not lead excess of hereditary illness as it was to be feared in 1959 for several countries. Considering that for populations the exposure levels induced by human activities have already been, under these ones of average natural exposures the genetic risk can be negligible and it is the somatic risk alone, with its thresholds that has to be into account. (N.C.)

  13. Establishment of source related dose constraints for members of the public. Interim report for comment

    International Nuclear Information System (INIS)

    1992-09-01

    The International Commission on Radiological Protection is proposing a new concept that it terms a ''dose constraint''. A dose constraint is an individual-related criterion applied to a single radiation source, and fixes an upper value for exposure of the critical group from that source. A dose restraint sets a ceiling on the levels of individual dose that can be considered in the optimization of radiological protection for a single source. 6 refs, 1 fig., 2 tabs

  14. Measurement of Patient Dose from Computed Tomography Using Physical Anthropomorphic Phantom

    International Nuclear Information System (INIS)

    Jang, Ki Won; Lee, Jae Ki; Kim, Jong Kyung

    2005-01-01

    The computed tomography (CT) provides a high quality in images of human body but contributes relatively high patient dose compared with the conventional X-ray examination. Furthermore, the frequency of CT examination has been increasing in Korea for the last decade owing to the national health insurance benefits. Increasing concerns about high patient dose from CT have stimulated a great deal of researches on dose assessment, which many of these are based on the Monte Carlo simulation. But in this study, absorbed doses and effective dose of patient undergoing CT examination were determined experimentally using anthropomorphic physical phantom and the measured results are compared with those from Monte Carlo calculation

  15. Relationship between Individual External Doses, Ambient Dose Rates and Individuals' Activity-Patterns in Affected Areas in Fukushima following the Fukushima Daiichi Nuclear Power Plant Accident.

    Directory of Open Access Journals (Sweden)

    Wataru Naito

    Full Text Available The accident at Fukushima Daiichi Nuclear Power Plant on March 11, 2011, released radioactive material into the atmosphere and contaminated the land in Fukushima and several neighboring prefectures. Five years after the nuclear disaster, the radiation levels have greatly decreased due to physical decay, weathering, and decontamination operations in Fukushima. The populations of 12 communities were forced to evacuate after the accident; as of March 2016, the evacuation order has been lifted in only a limited area, and permanent habitation is still prohibited in most of the areas. In order for the government to lift the evacuation order and for individuals to return to their original residential areas, it is important to assess current and future realistic individual external doses. Here, we used personal dosimeters along with the Global Positioning System and Geographic Information System to understand realistic individual external doses and to relate individual external doses, ambient doses, and activity-patterns of individuals in the affected areas in Fukushima. The results showed that the additional individual external doses were well correlated to the additional ambient doses based on the airborne monitoring survey. The results of linear regression analysis suggested that the additional individual external doses were on average about one-fifth that of the additional ambient doses. The reduction factors, which are defined as the ratios of the additional individual external doses to the additional ambient doses, were calculated to be on average 0.14 and 0.32 for time spent at home and outdoors, respectively. Analysis of the contribution of various activity patterns to the total individual external dose demonstrated good agreement with the average fraction of time spent daily in each activity, but the contribution due to being outdoors varied widely. These results are a valuable contribution to understanding realistic individual external doses

  16. Dose-rate effects in plateau-phase cultures of S3 HeLa and V79 cells

    International Nuclear Information System (INIS)

    Mitchell, J.B.; Bedford, J.S.; Bailey, S.M.

    1979-01-01

    Dose-rate effects on cell survival were studied for log-, fed plateau-, and unfed plateau-phase cultures of V79 and S3 HeLa cells. For log-phase cultures, repair, cell-cycle redistribution, and cell division during exposure can contribute to the overall dose-rate effect, but their relative contributions are difficult to determine. With plateau-phase cultures, the cell-cycle times are greatly lengthened, for those cells that are in cycle. Hence, the contribution to the overall dose-rate effect of cell-cycle redistribution and cell division during the exposure could be minimized using plateau-phase cultures. With respect to the acute dose-survival curves, there was a clear loss in effectiveness when the dose rate was lowered to 154 rad/hr for both fed and unfed plateau-phase HeLa and V79 cells. There was no further reduction in effectiveness per unit dose, however, when the dose rate was reduced to 55 rad/hr. Since there was virtually no cell division or cell-cycle redistribution, it may be that a limit to the repair-dependent dose-rate effect at 37 0 C has been reached at a dose rate of 154 rad/hr

  17. Contribution of inhalation by food animals to man's ingestion dose

    International Nuclear Information System (INIS)

    Zach, R.

    1985-01-01

    Animals' inhalation (AI) pathway was evaluated for 57 radionuclides using infant dose predictions from the food-chain model LIMCAL. With ingestion transfer coefficients fMi to define transfer from the respiratory tract to milk, the AI pathway appeared to be insignificant compared to animals' plant ingestion, as implicitly assumed in most environmental assessment models for nuclear installations. Using ICRP Publication 30 respiratory clearance models for man to adjust ingestion transfer coefficients, animals' inhalation appeared to be important, particularly for some actinide radionuclides. The AI pathway also appeared to be significant relative to man's inhalation, especially for infants. The importance of the AI pathway varied greatly between radionuclides, and results strongly suggest that it cannot be ignored in environmental assessments. Until better data become available to implement this pathway fully, adjusted ingestion transfer coefficient values can be used for transfer from animals' respiratory tract to milk and other food products

  18. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  19. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  20. Relative Contribution of Perception/Cognition and Language on Spatial Categorization

    Science.gov (United States)

    Choi, Soonja; Hattrup, Kate

    2012-01-01

    This study investigated the relative contribution of perception/cognition and language-specific semantics in nonverbal categorization of spatial relations. English and Korean speakers completed a video-based similarity judgment task involving containment, support, tight fit, and loose fit. Both perception/cognition and language served as resources…

  1. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  2. Dose estimate of exposure to radioisotopes in molecular and cellular biology

    International Nuclear Information System (INIS)

    Onado, C.; Faretta, M.; Ubezio, P.

    1999-01-01

    A method for prospectively evaluating the annual equivalent doses and effective dose to biomedical researchers working with unsealed radioisotopes, and their classification, is presented here. Simplified formulae relate occupational data to a reasonable overestimate of the annual effective dose, and the equivalent doses to the hands and to the skin. The procedure, up to the classification of personnel and laboratories, can be made fully automatic, using a common spreadsheet on a personal computer. The method is based on occupational data, accounting for the amounts of each radioisotope used by a researcher, the time of exposure and the overall amounts employed in the laboratories where experiments are performed. The former data serve to forecast a contribution to the dose arising from a researcher's own work, the latter to a forecast of an 'environmental' contribution deriving simply from the presence in a laboratory where other people are working with radioisotopes. The estimates of the doses due to one's own radioisotope handling and to 'environment' were corrected for accidental exposure, considered as a linear function of the manipulated activity or of the time spent in the laboratories respectively, and summed up to give the effective dose. The effective dose associated with some common experiments in molecular and cellular biology is pre-evaluated by this method. (author)

  3. Interpretation of proton relative biological effectiveness using lesion induction, lesion repair, and cellular dose distribution

    International Nuclear Information System (INIS)

    Paganetti, H.

    2005-01-01

    Phenomenological biophysical models have been successfully used to estimate the relative biological effectiveness (RBE) of ions. The predictive power of these models is limited because they require measured dose-response data that are not necessarily available for all clinically relevant end points. Furthermore, input parameters often lack mechanistic interpretation. In order to link RBE to more fundamental biological parameters we combine the concepts of two well-established biophysical models, i.e., the phenomenological 'track structure' model and the more mechanistic 'lethal lesion/potentially lethal lesion' (LPL) model. We parametrize a relation between RBE, dose homogeneity in the cell nucleus and induction rates for different lesion types. The macroscopic dose-response relationship is described in the LPL model and the microscopic, subcellular, relationship is determined by the local dose deposition pattern. The formalism provides a framework for a mechanistic interpretation of RBE values

  4. Age-dependent dose factors and dose limits of annual radioactivity uptake with unsealed radioactive substances by occupationally exposed persons

    International Nuclear Information System (INIS)

    Kaul, A.; Nosske, D; Elsasser, U; Roedler, H.D.; Henrichs, K.

    1986-01-01

    The dose factors have been calculated on the basis of the ICRP models for dosimetric and metabolistic assessment, and are laid open in accordance with Annex XI ( to sec. 45 sub-section (2)) of the amended version of the Radiation Protection Ordinance. The contribution in hand explains the scientific fundamentals and results of the calculations of dose factors relating to inhalation and ingestion of unsealed radioactive substances by adult reference man, and age-dependent factors calculated for children and adolescents. Further, annual limits of uptake by occupationally exposed persons, as calculated on the basis of primary dose limits pursunant to the draft amendment presented by the Federal Interior Minister, are compared with relevant data given by the ICRP and EC institutions. (orig./DG) [de

  5. Computational assessment of effective dose and patient specific doses for kilovoltage stereotactic radiosurgery of wet age-related macular degeneration

    Science.gov (United States)

    Hanlon, Justin Mitchell

    Age-related macular degeneration (AMD) is a leading cause of vision loss and a major health problem for people over the age of 50 in industrialized nations. The current standard of care, ranibizumab, is used to help slow and in some cases stabilize the process of AMD, but requires frequent invasive injections into the eye. Interest continues for stereotactic radiosurgery (SRS), an option that provides a non-invasive treatment for the wet form of AMD, through the development of the IRay(TM) (Oraya Therapeutics, Inc., Newark, CA). The goal of this modality is to destroy choroidal neovascularization beneath the pigment epithelium via delivery of three 100 kVp photon beams entering through the sclera and overlapping on the macula delivering up to 24 Gy of therapeutic dose over a span of approximately 5 minutes. The divergent x-ray beams targeting the fovea are robotically positioned and the eye is gently immobilized by a suction-enabled contact lens. Device development requires assessment of patient effective dose, reference patient mean absorbed doses to radiosensitive tissues, and patient specific doses to the lens and optic nerve. A series of head phantoms, including both reference and patient specific, was derived from CT data and employed in conjunction with the MCNPX 2.5.0 radiation transport code to simulate treatment and evaluate absorbed doses to potential tissues-at-risk. The reference phantoms were used to evaluate effective dose and mean absorbed doses to several radiosensitive tissues. The optic nerve was modeled with changeable positions based on individual patient variability seen in a review of head CT scans gathered. Patient specific phantoms were used to determine the effect of varying anatomy and gaze. The results showed that absorbed doses to the non-targeted tissues were below the threshold levels for serious complications; specifically the development of radiogenic cataracts and radiation induced optic neuropathy (RON). The effective dose

  6. Relative biological effectiveness of 125I seeds for low-dose-rate irradiation of PANC-1

    International Nuclear Information System (INIS)

    Wang Jidong; Wang Junjie; Zhuang Hongqing; Liao Anyan; Zhao Yong

    2008-01-01

    Objective: To investigate the relative biological effectiveness(RBE) of National Model 6711 125 I seeds and the response patterns of PANC-1 exposed to 125 I seeds irradiation. Methods: PANC-1 cells in exponential growth were irradiated at initial dose rate of 2.59 cGy/h in vitro and exposed to 1, 2, 4, 6, 8 and 10 Gy. Meanwhile, the other part of cells were exposed to the same doses by 60 Co at dose rate of 2.21 Gy/min. After irradiation, the cells were stained by trypan blue to measure the cellular mortality rate and to compare the changes along with plating times of 12, 24, 48 and 72 h after 4 Gy. The colonies were counted to obtain the plating efficiencies by colony-forming assay and the cell surviving faction was calculated to plot cell survival curves, and RBE of 125 I seeds relative to 60 Co was determined. Results: The cell death rate for continuous low- dose-rate (LDR) irradiation by 125 I seeds was greater than 60 Co at the same doses above or equal to 4 Gy. After 4 Gy irradiation, the cellular mortality rates were increased with times. The difference was significant between 125 I seeds and 60 Co. The survival fractions of 125 I were lower than those of 60 Co, and the RBE of 125 I relative to 60 Co was determined to be 1.45. Conclusion: The cell-killing effects for continuous low-dose-rate (LDR) irradiation by 125 I seeds are greater than acute high-dose-rate of 60 Co. (authors)

  7. Dose-related ethanol intake, Cx43 and Nav1.5 remodeling: Exploring insights of altered ventricular conduction and QRS fragmentation in excessive alcohol users.

    Science.gov (United States)

    Hung, Chung-Lieh; Lai, Yu-Jun; Chi, Po-Ching; Chen, Liang-Chia; Tseng, Ya-Ming; Kuo, Jen-Yuan; Lin, Cheng-I; Chen, Yao-Chang; Lin, Shing-Jong; Yeh, Hung-I

    2018-01-01

    Chronic, excessive ethanol intake has been linked with various electrical instabilities, conduction disturbances, and even sudden cardiac death, but the underlying cause for the latter is insufficiently delineated. We studied surface electrocardiography (ECG) in a community-dwelling cohort with moderate-to-heavy daily alcohol intake (grouped as >90g/day, ≤90g/day, and nonintake). Compared with nonintake, heavier alcohol users showed markedly widened QRS duration and higher prevalence of QRS fragmentation (64.3%, 50.9%, and 33.7%, respectively, χ 2 12.0, both pchronically given a 4% or 6% alcohol diet and showed dose-related slower action potential upstroke, reduced resting membrane potential, and disorganized or decreased intraventricular conduction (all pChronic excessive alcohol ingestion is associated with dose-related phenotypic intraventricular conduction disturbances and QRS fragmentation that can be recapitulated in mice. The mechanisms may involve suppressed gap junction and sodium channel functions, together with enhanced cardiac fibrosis that may contribute to arrhythmogenesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Dose-Related Effect of Extracorporeal Shock Wave Therapy for Plantar Fasciitis

    Science.gov (United States)

    Lee, Su-Jin; Kang, Jung-Ho; Kim, Ja-Young; Kim, Jin-Hong; Jung, Kwang-Ik

    2013-01-01

    Objective To examine the dose-related effect of extracorporeal shock wave therapy (ESWT) for plantar fasciitis. Methods Sixty patients with plantar fasciitis despite conservative treatment were enrolled. The patients were divided into a low-energy group (group L: n=30, 1,000 shocks/session, energy flux density [EFD] per shock 0.08 mJ/mm2) and a medium-energy group (group M: n=30, 1,000 shocks/session, EFD 0.16 mJ/mm2). The main outcome measures were visual analogue scale (VAS), Roles and Maudsley (RM) score, and thickness of plantar fascia (PF). To compare the effects between each group, follow-up was carried out 1 week after 3 and 6 sessions, and 1 and 3 months after ESWT. Results Significant VAS and RM score improvement, and PF thickness reduction were observed in both groups (p0.05). Conclusion Therapeutic effect might disclose a dose-related relationship; therefore, EFD and the times of the session are considerable factors when treating with ESWT. PMID:23869336

  9. Low-dose radiation therapy for choroidal neovascularization in age-related macular degeneration

    International Nuclear Information System (INIS)

    Matsuhashi, Hideaki; Takahashi, Daisuke; Mariya, Yasushi; Tarusawa, Nobuko; Yoshimoto, Hiroshi; Matsuyama, Shuichi; Noda, Yasuko.

    1996-01-01

    The efficacy of low-dose radiation was evaluated in the treatment of eyes with subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. Ten eyes of ten patients received a total dose of 14 Gy of 10 MV X-rays in seven fractions and the mean follow-up time was 12 months (range 9-18 months). Thirteen control eyes of thirteen patients were followed for an average of 18 months (range 12-24 months). Visual acuity was improved in 2 eyes (20%), unchanged in 3 eyes (30%), and deteriorated in 5 eyes (50%) of treated patients, and it was improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients at their last follow-up examinations. Funduscopic and angiographic findings were improved in 3 eyes (30%), unchanged in 2 eyes (20%), and deteriorated in 5 eyes (50%) of treated patients, and they were improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients. These results suggested that low-dose radiation is beneficial for the management of subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. (author)

  10. Low-dose radiation therapy for choroidal neovascularization in age-related macular degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Matsuhashi, Hideaki; Takahashi, Daisuke; Mariya, Yasushi; Tarusawa, Nobuko; Yoshimoto, Hiroshi; Matsuyama, Shuichi [Hirosaki Univ., Aomori (Japan). School of Medicine; Noda, Yasuko

    1996-10-01

    The efficacy of low-dose radiation was evaluated in the treatment of eyes with subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. Ten eyes of ten patients received a total dose of 14 Gy of 10 MV X-rays in seven fractions and the mean follow-up time was 12 months (range 9-18 months). Thirteen control eyes of thirteen patients were followed for an average of 18 months (range 12-24 months). Visual acuity was improved in 2 eyes (20%), unchanged in 3 eyes (30%), and deteriorated in 5 eyes (50%) of treated patients, and it was improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients at their last follow-up examinations. Funduscopic and angiographic findings were improved in 3 eyes (30%), unchanged in 2 eyes (20%), and deteriorated in 5 eyes (50%) of treated patients, and they were improved in no eyes (0%), unchanged in 5 eyes (32%), and deteriorated in 8 eyes (50%) of the control patients. These results suggested that low-dose radiation is beneficial for the management of subfoveal or juxtafoveal choroidal neovascularization in age-related macular degeneration. (author)

  11. Radiation dose contribution from coal-slags used as structural building material

    International Nuclear Information System (INIS)

    Somlai, J.; Kanyar, B.; Bodnar, R.; Lendvai, Z.; Nemeth, Cs.

    1996-01-01

    A significant dose distribution on the population could be derived from coal slags used as isolation material. Extremely high natural activities are measured in the coal slag, derived from the region of the settlement Ajka, Hungary. In some buildings monitored, the elevated γ-doses were nearly 5-10 times higher than the world average ones. The annual average indoor radon concentrations from the slag exceeded 400 Bq/m 3 and in some cases up to 1200 Bq/m 3 . Due to the elevated exposure and the radon concentrations in the dwellings the annual dose was estimated to 8-24 mSv/y more than 5-10 times of the world average one. (author). 10 refs., 1 fig., 3 tabs

  12. Radiation doses and risks from internal emitters

    International Nuclear Information System (INIS)

    Harrison, John; Day, Philip

    2008-01-01

    This review updates material prepared for the UK Government Committee Examining Radiation Risks from Internal Emitters (CERRIE) and also refers to the new recommendations of the International Commission on Radiological Protection (ICRP) and other recent developments. Two conclusions from CERRIE were that ICRP should clarify and elaborate its advice on the use of its dose quantities, equivalent and effective dose, and that more attention should be paid to uncertainties in dose and risk estimates and their implications. The new ICRP recommendations provide explanations of the calculation and intended purpose of the protection quantities, but further advice on their use would be helpful. The new recommendations refer to the importance of understanding uncertainties in estimates of dose and risk, although methods for doing this are not suggested. Dose coefficients (Sv per Bq intake) for the inhalation or ingestion of radionuclides are published as reference values without uncertainty. The primary purpose of equivalent and effective dose is to enable the summation of doses from different radionuclides and from external sources for comparison with dose limits, constraints and reference levels that relate to stochastic risks of whole-body radiation exposure. Doses are calculated using defined biokinetic and dosimetric models, including reference anatomical data for the organs and tissues of the human body. Radiation weighting factors are used to adjust for the different effectiveness of different radiation types, per unit absorbed dose (Gy), in causing stochastic effects at low doses and dose rates. Tissue weighting factors are used to take account of the contribution of individual organs and tissues to overall detriment from cancer and hereditary effects, providing a simple set of rounded values chosen on the basis of age- and sex-averaged values of relative detriment. While the definition of absorbed dose has the scientific rigour required of a basic physical quantity

  13. The radiation dose to accompanying nurses, relatives and other patients in a nuclear medicine department waiting room

    Energy Technology Data Exchange (ETDEWEB)

    Harding, L K; Harding, N J; Warren, H; Mills, A; Thomson, W H [Dudley Road Hospital, Birmingham (UK)

    1990-01-01

    The radiation dose to accompanying nurses, relatives and other patients in a nuclear medicine department waiting room was assessed at 5 min intervals by observing the seating arrangement. The total radiation dose to each person was calculated, using fixed values of dose rate per 100 MBq activity for radionuclides, and applying the inverse square law. Radioactive decay and attenuation effects due to intervening persons were also taken into account. The median radiation doses to accompanying nurses, relatives and other patients were 2.3, 2.0 and 0.2 {mu}Sv with maximum values of 17, 33 and 5 {mu}Sv respectively. In all cases, the radiation dose received by patients was less than 0.2% of the radiation dose resulting from their own investigation. Also, the maximum radiation dose received by an accompanying norse or friend was less than 1% of their appropriate annual dose limit. Similar values were obtained with calculations based on a 15 min time interval. The radiation doses received by those in a nuclear medicine department waiting room are small, and separate waiting room facilities for radioactive patients are unnecessary. (author).

  14. Enchanced total dose damage in junction field effect transistors and related linear integrated circuits

    International Nuclear Information System (INIS)

    Flament, O.; Autran, J.L.; Roche, P.; Leray, J.L.; Musseau, O.

    1996-01-01

    Enhanced total dose damage of Junction Field-effect Transistors (JFETs) due to low dose rate and/or elevated temperature has been investigated for elementary p-channel structures fabricated on bulk and SOI substrates as well as for related linear integrated circuits. All these devices were fabricated with conventional junction isolation (field oxide). Large increases in damage have been revealed by performing high temperature and/or low dose rate irradiations. These results are consistent with previous studies concerning bipolar field oxides under low-field conditions. They suggest that the transport of radiation-induced holes through the oxide is the underlying mechanism. Such an enhanced degradation must be taken into account for low dose rate effects on linear integrated circuits

  15. Some thoughts on tolerance, dose, and fractionation in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gahbauer, R.; Goodman, J.; Blue, T.

    1988-01-01

    Unique to boron neutron capture therapy, the tolerance very strongly depends on the boron concentration in normal brain, skin and blood. If one first considers the ideal situation of a 2 KeV beam and a compound clearing from normal tissues and blood, the tolerance dose to epithermal beams relates to the maximum tolerated capture gamma dose and capture high LET dose, H (n,gamma)D and N(n,p) 14 C. The authors can relate this gamma and high LET dose to known clinical experience. Assuming gamma and high LET dose ratios as given by Fairchild and Bond, one may first choose a clearly safe high LET whole brain dose and calculate the unavoidably resulting gamma dose. To a first approximation 500 cGy of high LET dose results in 3,000 cGy gamma dose. One can speculate that this approximates the tolerance of whole brain to the 2 KeV beam with no contributing boron dose if the radiation is fractionated. It would clearly be beyond tolerance in a single fraction where most therapists would be uncomfortable to deliver even one third of the above doses

  16. Warfarin dose and INR related to genotypes of CYP2C9 and VKORC1 in patients with myocardial infarction

    Directory of Open Access Journals (Sweden)

    Seljeflot Ingebjørg

    2008-06-01

    Full Text Available Abstract Background Warfarin treatment has a narrow therapeutic range, requiring meticulous monitoring and dosage titration. Individual dosage requirement has recently partly been explained by genetic variation of the warfarin metabolizing enzyme CYP2C9 and the Vitamin K-activating enzyme VKORC1. In the WARIS-II study, comparing three different antithrombotic regimens after myocardial infarction, warfarin treatment reduced thrombotic events, but was associated with more frequent bleeding than use of acetylsalisylic acid (ASA alone. Aims The primary aim of the present study was to investigate the relation between genotypes of CYP2C9 and VKORC1 and warfarin maintenance dose in myocardial infarction. The secondary aim was to relate the genotypes to international normalized ratio (INR. Methods Genotyping was performed in 212 myocardial infarction patients from the WARIS-II study by robotic isolation of DNA from EDTA whole blood (MagNa Pure LC before PCR amplification (LightCycler and melting point analysis. Results The 420 C>T substitution of CYP2C9*2, the 1075 A>C substitution of CYP2C9*3 and the 1173 C>T substitution of VKORC1 had minor allele frequencies of, 11.3%, 5.7% and 36.6% respectively. Warfarin weekly dose varied between 17 mg and 74 mg among the patients. INR did not vary between genotypes. Warfarin dosage requirement was significantly associated with CYP2C9 and VKORC1 genotypes, treatment group and age. The VKORC1 genotype contributed 24.5% to the interindividual variation in warfarin dosage, whereas the combined CYP2C9 genotypes were only responsible for 7.2% of the dose variation. Conclusion CYP2C9 and VKORC1 genotype frequencies in myocardial infarction patients appear similar to other patient groups and have similar impact on warfarin maintenance dose.

  17. The relative labour productivity contribution of different age-skill categories for a developing economy

    Directory of Open Access Journals (Sweden)

    Gerhardus van Zyl

    2013-01-01

    Full Text Available Orientation: The article dealt with the estimation, computation and interpretation of the relative productivity contributions of different age-skill categories. Research purpose: The aim of the article was to estimate and compute, (1 relative productivity contributions and (2 relative productivity contribution–employee remuneration cost levels for different age-skill categories. Motivation for the study: The research was deemed necessary given the current debate on relative productivity levels and possible changes to the retirement age in the South African labour market. No real research in this regard has been published regarding the South African labour market situation. Research design, approach and method: A less restrictive production function was used, allowing for the simultaneous estimation and final computation of relative labour contribution levels of different age-skill categories. Main findings: The lower-skilled segment produced significantly smaller productivity contributions and the relative productivity contribution–employee remuneration cost ratios of the 55 years and older age group were superior in the higher-skilled segment but, at the same time, the lowest in the lower-skilled segment. Practical/managerial implications: It is recommended that human resource practitioners (given the perceived rigidity of labour legislation implement and maintain structures that promote higher productivity levels for all age-skill categories in the workplace. Contribution/value-add: An estimation procedure, which can be applied to the measurement of the relative productivity contribution of different age-skill categories, has been established.

  18. The relative labour productivity contribution of different age-skill categories for a developing economy

    Directory of Open Access Journals (Sweden)

    Gerhardus van Zyl

    2013-01-01

    Full Text Available Orientation: The article dealt with the estimation, computation and interpretation of the relative productivity contributions of different age-skill categories.Research purpose: The aim of the article was to estimate and compute, (1 relative productivity contributions and (2 relative productivity contribution–employee remuneration cost levels for different age-skill categories.Motivation for the study: The research was deemed necessary given the current debate on relative productivity levels and possible changes to the retirement age in the South African labour market. No real research in this regard has been published regarding the South African labour market situation.Research design, approach and method: A less restrictive production function was used, allowing for the simultaneous estimation and final computation of relative labour contribution levels of different age-skill categories.Main findings: The lower-skilled segment produced significantly smaller productivity contributions and the relative productivity contribution–employee remuneration cost ratios of the 55 years and older age group were superior in the higher-skilled segment but, at the same time, the lowest in the lower-skilled segment.Practical/managerial implications: It is recommended that human resource practitioners (given the perceived rigidity of labour legislation implement and maintain structures that promote higher productivity levels for all age-skill categories in the workplace.Contribution/value-add: An estimation procedure, which can be applied to the measurement of the relative productivity contribution of different age-skill categories, has been established.

  19. Estimation of the contribution of neutrons to the equivalent dose for personnel occupationally exposed and public in medical facilities: X-ray with energy equal or greater than 10MV

    International Nuclear Information System (INIS)

    Gonzalez, Alfonso Mayer; Jimenez, Roberto Ortega; Sanchez, Mario A. Reyes; Moranchel y Mejia, Mario

    2013-01-01

    In Mexico the use of electron accelerators for treating cancerous tumors had grown enormously in the last decade. When the treatments are carried out with X-ray beam energy below 10 MV the design of the shielding of the radioactive facility is determined by analyzing the interaction of X-rays, which have a direct impact and dispersion, with materials of the facility. However, when it makes use of X-ray beam energy equal to or greater than 10 MV the neutrons presence is imminent due to their generation by the interaction of the primary beam X-ray with materials head of the accelerator and of the table of treatment, mainly. In these cases, the design and calculation of shielding considers the generation of high-energy neutrons which contribute the equivalent dose that public and Occupationally Staff Exposed (POE) will receive in the areas surrounding the facility radioactive. However, very few measurements have been performed to determine the actual contribution to the neutron dose equivalent received by POE and public during working hours. This paper presents an estimate of the actual contribution of the neutron dose equivalent received by public and POE facilities in various radioactive medical use, considering many factors. To this end, measurements were made of the equivalent dose by using a neutron monitor in areas surrounding different radioactive installations (of Mexico) which used electron accelerators medical use during treatment with X-ray beam energy equal to or greater than 10 MV. The results are presented after a statistical analysis of a wide range of measures in order to estimate more reliability real contribution of the neutron dose equivalent for POE and the public. (author)

  20. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.; Tebes, C.L.

    1995-01-01

    A preliminary radiological dose assessment related to equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials in production waste streams. The assessment evaluated the relative dose of these activities and included a sensitivity analysis of certain input parameters. Future studies and potential policy actions are recommended

  1. I-131 Dose Response for Incident Thyroid Cancers in Ukraine Related to the Chornobyl Accident

    OpenAIRE

    Brenner, Alina V.; Tronko, Mykola D.; Hatch, Maureen; Bogdanova, Tetyana I.; Oliynik, Valery A.; Lubin, Jay H.; Zablotska, Lydia B.; Tereschenko, Valery P.; McConnell, Robert J.; Zamotaeva, Galina A.; O?Kane, Patrick; Bouville, Andre C.; Chaykovskaya, Ludmila V.; Greenebaum, Ellen; Paster, Ihor P.

    2011-01-01

    Background: Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case?control studies, and studies of prevalent cancers. Objective: To address this limitation, we evaluated the dose?response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. Methods: The cohort consists of individuals < 18 years of age on 26 April 1986 who ...

  2. Tracheobronchial and Alveolar Particle Surface Area Doses in Smokers

    Directory of Open Access Journals (Sweden)

    Fernanda Carmen Fuoco

    2017-01-01

    Full Text Available Cigarette smoke is the main cause of lung cancer events. Mainstream cigarette smoke (MSS is a direct concern for smokers, but also the secondhand smoke (SHS contributes to the smoker exposure. In addition, smoker exposure is affected by the “free-smoke” particle exposure (B, related to the micro-environments where smokers spend time. The aim of this paper is to evaluate the daily alveolar and tracheobronchial deposited fractions of airborne particles for smokers as the sum of these three contributions: MSS, SHS, and B. Measurements of particle surface area distributions in the MSS were performed through a Scanning Mobility Particle Sizer, an Aerodynamic Particle Sizer, and a Thermo-dilution system on five types of conventional cigarettes. A Monte Carlo method was then applied to evaluate the most probable value of dose received during the inhalation of MSS by smokers. Measurements of particle concentrations in SHS and at the “free-smoke” particle background (B were performed through 24-h monitoring at a personal scale of adult smoker through hand-held devices. This paper found that the total daily deposited dose for typical smokers was 1.03 × 105 mm2·day−1. The main contribution of such a huge daily dose was addressable to the MSS (98% while SHS contributed 1.1%, increasing up to 2% for people smoking only while traveling in a car.

  3. Dose response and factors related to interstitial pneumonitis after bone marrow transplant

    International Nuclear Information System (INIS)

    Sampath, Sagus; Schultheiss, Timothy E.; Wong, Jeffrey

    2005-01-01

    Purpose: Total body irradiation (TBI) and chemotherapy are common components of conditioning regimens for bone marrow transplantation. Interstitial pneumonitis (IP) is a known regimen-related complication. Using published data of IP in a multivariate logistic regression, this study sought to identify the parameters in the bone marrow transplantation conditioning regimen that were significantly associated with IP and to establish a radiation dose-response function. Methods and Materials: A retrospective review was conducted of articles that reported IP incidence along with lung dose, fractionation, dose rate, and chemotherapy regimen. In the final analysis, 20 articles (n = 1090 patients), consisting of 26 distinct TBI/chemotherapy regimens, were included in the analysis. Multivariate logistic regression was performed to determine dosimetric and chemotherapeutic factors that influenced the incidence of IP. Results: A logistic model was generated from patients receiving daily fractions of radiation. In this model, lung dose, cyclophosphamide dose, and the addition of busulfan were significantly associated with IP. An incidence of 3%-4% with chemotherapy-only conditioning regimens is estimated from the models. The α/β value of the linear-quadratic model was estimated to be 2.8 Gy. The dose eliciting a 50% incidence, D 50 , for IP after 120 mg/kg of cyclophosphamide was 8.8 Gy; in the absence of chemotherapy, the estimated D 50 is 10.6 Gy. No dose rate effect was observed. The use of busulfan as a substitute for radiation is equivalent to treating with 14.8 Gy in 4 fractions with 50% transmission blocks shielding the lung. The logistic regression failed to find a model that adequately fit the multiple-fraction-per-day data. Conclusions: Dose responses for both lung radiation dose and cyclophosphamide dose were identified. A conditioning regimen of 12 Gy TBI in 6 daily fractions induces an IP incidence of about 11% in the absence of lung shielding. Shielding the lung

  4. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  5. Measurement of radiation dose with a PC-based instrument

    International Nuclear Information System (INIS)

    Jangland, L.; Neubeck, R.

    1994-01-01

    The purpose of this study was to investigate in what way the introduction of Digital Subtraction Angiography has influenced absorbed doses to the patient and personnel. Calculation of the energy imparted to the patient, ε, was based on measurements of the dose-area product, tube potential and tube current which were registered with a PC-based instrument. The absorbed doses to the personnel were measured with TLD. The measurements on the personnel were made only at the digital system. The results indicate large variations in ε between different types of angiographic examinations of the same type. The total ε were similar on both systems, although the relative contribution from image acquisition and fluoroscopy were different. At the conventional system fluoroscopy and image acquisition contributed almost equally to the total ε. At the digital system 25% of the total ε was due to fluoroscopy and 75% to image acquisition. The differences were due to longer fluoroscopic times on the conventional system, mainly due to lack of image memory and road mapping, and lower ε/image, due to lower dose settings to the film changer compared to the image intensifier on the digital system. 11 refs., 8 figs., 9 tabs

  6. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Dose-Related Modulation of Event-Related Potentials to Novel and Target Stimuli by Intravenous Δ9-THC in Humans

    Science.gov (United States)

    D'Souza, Deepak Cyril; Fridberg, Daniel J; Skosnik, Patrick D; Williams, Ashley; Roach, Brian; Singh, Nagendra; Carbuto, Michelle; Elander, Jacqueline; Schnakenberg, Ashley; Pittman, Brian; Sewell, R Andrew; Ranganathan, Mohini; Mathalon, Daniel

    2012-01-01

    Cannabinoids induce a host of perceptual alterations and cognitive deficits in humans. However, the neural correlates of these deficits have remained elusive. The current study examined the acute, dose-related effects of delta-9-tetrahydrocannabinol (Δ9-THC) on psychophysiological indices of information processing in humans. Healthy subjects (n=26) completed three test days during which they received intravenous Δ9-THC (placebo, 0.015 and 0.03 mg/kg) in a within-subject, double-blind, randomized, cross-over, and counterbalanced design. Psychophysiological data (electroencephalography) were collected before and after drug administration while subjects engaged in an event-related potential (ERP) task known to be a valid index of attention and cognition (a three-stimulus auditory ‘oddball' P300 task). Δ9-THC dose-dependently reduced the amplitude of both the target P300b and the novelty P300a. Δ9-THC did not have any effect on the latency of either the P300a or P300b, or on early sensory-evoked ERP components preceding the P300 (the N100). Concomitantly, Δ9-THC induced psychotomimetic effects, perceptual alterations, and subjective ‘high' in a dose-dependent manner. Δ9-THC -induced reductions in P3b amplitude correlated with Δ9-THC-induced perceptual alterations. Lastly, exploratory analyses examining cannabis use status showed that whereas recent cannabis users had blunted behavioral effects to Δ9-THC, there were no dose-related effects of Δ9-THC on P300a/b amplitude between cannabis-free and recent cannabis users. Overall, these data suggest that at doses that produce behavioral and subjective effects consistent with the known properties of cannabis, Δ9-THC reduced P300a and P300b amplitudes without altering the latency of these ERPs. Cannabinoid agonists may therefore disrupt cortical processes responsible for context updating and the automatic orientation of attention, while leaving processing speed and earlier sensory ERP components intact

  8. Dose/volume–response relations for rectal morbidity using planned and simulated motion-inclusive dose distributions

    International Nuclear Information System (INIS)

    Thor, Maria; Apte, Aditya; Deasy, Joseph O.; Karlsdóttir, Àsa; Moiseenko, Vitali; Liu, Mitchell; Muren, Ludvig Paul

    2013-01-01

    Background and purpose: Many dose-limiting normal tissues in radiotherapy (RT) display considerable internal motion between fractions over a course of treatment, potentially reducing the appropriateness of using planned dose distributions to predict morbidity. Accounting explicitly for rectal motion could improve the predictive power of modelling rectal morbidity. To test this, we simulated the effect of motion in two cohorts. Materials and methods: The included patients (232 and 159 cases) received RT for prostate cancer to 70 and 74 Gy. Motion-inclusive dose distributions were introduced as simulations of random or systematic motion to the planned dose distributions. Six rectal morbidity endpoints were analysed. A probit model using the QUANTEC recommended parameters was also applied to the cohorts. Results: The differences in associations using the planned over the motion-inclusive dose distributions were modest. Statistically significant associations were obtained with four of the endpoints, mainly at high doses (55–70 Gy), using both the planned and the motion-inclusive dose distributions, primarily when simulating random motion. The strongest associations were observed for GI toxicity and rectal bleeding (Rs = 0.12–0.21; Rs = 0.11–0.20). Applying the probit model, significant associations were found for tenesmus and rectal bleeding (Rs = 0.13, p = 0.02). Conclusion: Equally strong associations with rectal morbidity were observed at high doses (>55 Gy), for the planned and the simulated dose distributions including in particular random rectal motion. Future studies should explore patient-specific descriptions of rectal motion to achieve improved predictive power

  9. Indication-related dosing for magnetic resonance contrast media

    International Nuclear Information System (INIS)

    Yuh, W.T.C.; Parker, J.R.; Carvlin, M.J.

    1997-01-01

    This presentation reviews the issue of contrast media dosing and imaging protocols for the optimal MR imaging detection and characterization of pathology. The cumulative clinical experience gained in performing contrast-enhanced MR examinations with gadolinium chelates indicates that a dose of 0.1 mmol/kg body weight provides safe and effective enhancement of most CNS pathology. Doses lower than 0.1 mmol/kg have been shown to be inadequate for delineating all but selected types of CNS pathology, such as masses with a high lesion to background ratio on post-contrast images (acoustic neuromas) or lesions located in areas in which the normal tissue very rapidly takes up contrast agent (e. g. microadenomas in the pituitary gland). Recent clinical studies have suggested a role for high dose gadolinium administration (up to 0.3 mmol/kg) for the optimal detection and delineation of cerebral metastases or other small or poorly enhancing lesions. Differences in the histopathologic characteristics (capillary permeability, vascularity, location, size) of specific diseased tissues may require varying doses or even a different contrast agent to be used for optimal imaging results. As new MR contrast agents and new scanning techniques are introduced, the specific diagnostic question posed will likely determine the choice of pulse sequence, contrast agent and dose used. (orig.)

  10. beta. and. gamma. -comparative dose estimates on Enewetak Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L. (California Univ., Livermore (USA). Lawrence Livermore National Lab.)

    1982-05-01

    Enewetak Atoll in the Pacific is used for atmospheric testing of U.S. nuclear weapons. Beta dose and ..gamma..-ray exposure measurements were made on two islands of the Enewetak Atoll during July-August 1976 to determine the ..beta.. and low energy ..gamma..-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a ..beta..-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to ..beta..- or low energy ..gamma..-contribution. The contribution at any particular site, however, is reduced by vegetation. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey. Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the ..beta..'s or low energy ..gamma..'s, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  11. Patient-related factors determining geometry of intracavitary applicators and pelvic dose distribution during cervical cancer brachytherapy

    International Nuclear Information System (INIS)

    Senkus-Konefka, Elzbieta; Kobierska, Anna; Jassem, Jacek; Badzio, Andrezej

    1997-01-01

    Purpose: The aim of this study was to assess retrospectively the influence of the size of cervical cancer brachytherapy applicators (ovoids and uterine tandems) on pelvic dose distribution and to analyze the impact of various patient-and disease-related factors on applicators' geometry and on dose distribution in particular applications. Methods and Materials: The subject of this study were 356 cervical cancer patients treated with Selectron LDR as a part of their radical radiotherapy. Analyzed factors included patient age, weight, number of vaginal deliveries, and disease stage. Results: The use of larger vaginal applicators resulted in lower bladder and rectum doses and in higher point B doses (all p < 0.0001); longer uterine tandems produced lower rectum doses and higher point B doses (both p < 0.0001). Increasing patient age and disease stage resulted in a decreased frequency of use of large ovoids (both p < 0.0001) and of long tandems (age: p = 0.0069, stage: p = 0.004). As a result, higher doses to bladder (age: p < 0.0001, stage: p = 0.017) and rectum (age: p = 0.037, stage: p = 0.011) were observed. Increasing age also resulted in lower point B doses (p < 0.0001). Increasing patient weight correlated with less frequent use of long tandems (p = 0.0015) and with higher bladder doses (p = 0.04). Higher number of vaginal deliveries was related to the increase in the use of long tandems (p = 0.002); in patients who had had at least one vaginal delivery, point B doses were significantly higher (p = 0.0059). In multivariate analysis ovoid size and uterine tandem length were dependent on patient age (respectively: p < 0.001 and p = 0.001), disease stage (respectively: p = 0.003 and p = 0.008) and on the number of vaginal deliveries (respectively: p = 0.07 and p 0.008). Doses to critical organs and to points B were dependent on patient age (respectively: p < 0.001, p = 0.011, and p < 0.001) and on disease stage (respectively: p < 0.001, p = 0.004, and p = 0

  12. [Ranking of radionuclides and pathways according to their contribution to the dose burden to the population resulting from NPP releases].

    Science.gov (United States)

    Spiridonov, S I; Karpenko, E I; Sharpan, L A

    2013-01-01

    Approaches are described towards estimating the consequences of radioactive contamination of ecosystems by nuclear fuel cycle enterprises with the rationale for the optimal specification level for nuclear power plants (NPP) operating in the normal mode. Calculations are made based on the initial data of the IAEA project, INPRO ENV, dealing with the ranking of radionuclides escaping to the environment from the operating NPPs. Influence of various factors on rankings of radionuclides and pathways of public exposure is demon- strated. An important factor is the controlled radionuclide composition of atmospheric NPP releases. It has been found that variation in the dose coefficients for some radionuclides leads to significant changes not only in the ranking results but also in the estimates of total dose burdens. Invariability is shown of the estimation concerning the greatest contribution of the peroral route to the population dose of irradiation in the situation considered. A conclusion was drawn on the need of taking into consideration uncertainties of different factors when comparing effects on the environment from enterprises of conventional and innovative nuclear fuel cycles.

  13. Acute pancreatitis related to therapeutic dosing with colchicine: a case report

    Directory of Open Access Journals (Sweden)

    Ting Joseph

    2007-08-01

    Full Text Available Abstract Background Colchicine is used in the treatment and prophylaxis of gout. It possesses a narrow therapeutic window, frequently resulting in dose-limiting gastrointestinal side-effects such as diarrhoea and emesis. As colchicine is a cellular anti-mitotic agent, the most serious effects include myelosuppression, myoneuropathy and multiple organ failure. This occurs with intentional overdose or with therapeutic dosing in patients with reduced clearance of colchicine due to pre-existing renal or hepatic impairment. Acute pancreatitis has rarely been reported, and only in association with severe colchicine overdose accompanied by multi-organ failure. Case presentation We report a case of acute pancreatitis without other organ toxicity related to recent commencement of colchicine for acute gout, occurring in an elderly male with pre-existing renal impairment. Conclusion 1 Colchicine should be used with care in elderly patients or patients with impaired renal function. 2 Aside from myelosuppression, myoneuropathy and multiple organ failure, colchicine may now be associated with acute pancreatitis even with therapeutic dosing; this has not previously being reported.

  14. Dose assessment in the Marshall Islands

    International Nuclear Information System (INIS)

    Robison, William L.

    1978-01-01

    Bikini Atoll and Enewetak Atoll in the Marshall Islands were the sites of major U.S. weapons testing from 1948 through 1958. Both the Bikini and Knewetak people have expressed a desire to return to their native Atolls. In 1968 clean-up and resettlement of Bikini was begun. In 1972-73 the initial survey of Enewetak Atoll was conducted and clean-up began in 1977. Surveys have been conducted at both Atolls to establish the concentrations of radionuclides in the biota and to determine the external exposure rates. Subsequent to the surveys dose assessments have been made to determine the potential dose to returning (100) populations at both Atolls. This talk will include discussions of the relative importance of the critical exposure pathways (i.e., external exposure, inhalation, marine, terrestrial and drinking water), the predominant radionuclides contributing to the predicted doses for each pathway, the doses predicted for alternate living patterns, comparison to Federal Guidelines, the comparison between Atolls, some of the social problems created by adherence to Federal Guidelines and the follow-up research identified and initiated to help refine the dose assessments and better predict the long term use of the Atolls (86). (author)

  15. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  16. Sources of variability in OSL dose measurements using single grains of quartz

    International Nuclear Information System (INIS)

    Thomsen, K.J.; Murray, A.S.; Boetter-Jensen, L.

    2005-01-01

    In luminescence-based measurements of dose distributions in unheated mineral samples, the observed spread in dose values is usually attributed to four main factors: fluctuations in the number of photons counted, incomplete zeroing of any prior trapped charge (including signals arising from thermal transfer), heterogeneity in dosimetry, and instrument reproducibility. For correct interpretation of measured dose distributions in retrospective dosimetry, it is important to understand the relative importance of these components, and to establish whether other factors also contribute to the observed spread. In this preliminary study, dose distributions have been studied using single grains of heated and laboratory irradiated quartz. By heating the sample, the contribution from incomplete zeroing was excluded and at the same time the sample was sensitised. The laboratory gamma irradiation was designed to deliver a uniform dose to the sample. Thus it was anticipated that statistical fluctuations in the number of photons counted and instrument reproducibility, both quantifiable entities, should be able to account for all the observed variance in the measured dose distributions. We examine this assumption in detail, and discuss the origins and importance of the residual variance in our data

  17. Task-based measures of image quality and their relation to radiation dose and patient risk

    International Nuclear Information System (INIS)

    Barrett, Harrison H; Kupinski, Matthew A; Myers, Kyle J; Hoeschen, Christoph; Little, Mark P

    2015-01-01

    The theory of task-based assessment of image quality is reviewed in the context of imaging with ionizing radiation, and objective figures of merit (FOMs) for image quality are summarized. The variation of the FOMs with the task, the observer and especially with the mean number of photons recorded in the image is discussed. Then various standard methods for specifying radiation dose are reviewed and related to the mean number of photons in the image and hence to image quality. Current knowledge of the relation between local radiation dose and the risk of various adverse effects is summarized, and some graphical depictions of the tradeoffs between image quality and risk are introduced. Then various dose-reduction strategies are discussed in terms of their effect on task-based measures of image quality. (topical review)

  18. Relative radiation sensitivity of the integumentary system: Dose response of the epidermal, microvascular, and dermal populations

    International Nuclear Information System (INIS)

    Archambeau, J.O.

    1987-01-01

    This presentation lists gross and histologic changes produced by irradiation of the skin that have been quantified. It examines available cell kinetic radiobiological and morphological variables to identify interactions that occur between component populations. The dose response data of the hair and epidermal, fibrocytic, and endothelial cell populations are examined and a rank ordering is attempted. The contribution of the radiosensitivity of these populations to defining the dose tolerance of the skin is discussed. Future clinical needs are considered. The intent is to quantify or define tissue population changes in the irradiated skin so that the data may serve as guidelines to aid the radiation therapist to select therapy schedules that preserve skin function while improving cancer control

  19. High Dose MicroCT Does Not Contribute Toward Improved MicroPET/CT Image Quantitative Accuracy and Can Limit Longitudinal Scanning of Small Animals

    Directory of Open Access Journals (Sweden)

    Wendy A. McDougald

    2017-10-01

    Full Text Available Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1 to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2 to evaluate the absorbed dose associated with varying CT parameters.Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA software implemented by Mediso. Measured Hounsfield Unit (HU in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC, uniformity and quantitative bias were also measured.Results: Only less than 2 and 1% of CT acquisition protocols yielded water HU values < −80 and air HU values < −840, respectively. Four out of 11 CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration.Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed toward improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  20. I-131 dose response for incident thyroid cancers in Ukraine related to the Chornobyl accident.

    Science.gov (United States)

    Brenner, Alina V; Tronko, Mykola D; Hatch, Maureen; Bogdanova, Tetyana I; Oliynik, Valery A; Lubin, Jay H; Zablotska, Lydia B; Tereschenko, Valery P; McConnell, Robert J; Zamotaeva, Galina A; O'Kane, Patrick; Bouville, Andre C; Chaykovskaya, Ludmila V; Greenebaum, Ellen; Paster, Ihor P; Shpak, Victor M; Ron, Elaine

    2011-07-01

    Current knowledge about Chornobyl-related thyroid cancer risks comes from ecological studies based on grouped doses, case-control studies, and studies of prevalent cancers. To address this limitation, we evaluated the dose-response relationship for incident thyroid cancers using measurement-based individual iodine-131 (I-131) thyroid dose estimates in a prospective analytic cohort study. The cohort consists of individuals radioactivity measurements taken within 2 months after the accident, environmental transport models, and interview data. Excess radiation risks were estimated using Poisson regression models. Sixty-five incident thyroid cancers were diagnosed during the second through fourth screenings and 73,004 person-years (PY) of observation. The dose-response relationship was consistent with linearity on relative and absolute scales, although the excess relative risk (ERR) model described data better than did the excess absolute risk (EAR) model. The ERR per gray was 1.91 [95% confidence interval (CI), 0.43-6.34], and the EAR per 10⁴ PY/Gy was 2.21 (95% CI, 0.04-5.78). The ERR per gray varied significantly by oblast of residence but not by time since exposure, use of iodine prophylaxis, iodine status, sex, age, or tumor size. I-131-related thyroid cancer risks persisted for two decades after exposure, with no evidence of decrease during the observation period. The radiation risks, although smaller, are compatible with those of retrospective and ecological post-Chornobyl studies.

  1. Biological effects of low-dose ionizing radiation exposure

    International Nuclear Information System (INIS)

    Reinoehl-Kompa, Sabine; Baldauf, Daniela; Heller, Horst

    2009-01-01

    The report on the meeting of the Strahlenschutzkommission 2007 concerning biological effects of low-dose ionizing radiation exposure includes the following contributions: Adaptive response. The importance of DNA damage mechanisms for the biological efficiency of low-energy photons. Radiation effects in mammography: the relative biological radiation effects of low-energy photons. Radiation-induced cataracts. Carcinomas following prenatal radiation exposure. Intercellular apoptosis induction and low-dose irradiation: possible consequences for the oncogenesis control. Mechanistic models for the carcinogenesis with radiation-induced cell inactivation: application to all solid tumors in the Japanese atomic bomb survivors. Microarrays at low radiation doses. Mouse models for the analysis of biological effects of low-dose ionizing radiation. The bystander effect: observations, mechanisms and implications. Lung carcinoma risk of Majak workers - modeling of carcinogenesis and the bystander effect. Microbeam studies in radiation biology - an overview. Carcinogenesis models with radiation-induced genomic instability. Application to two epidemiological cohorts.

  2. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    International Nuclear Information System (INIS)

    Deng Jun; Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior–inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT–contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  3. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Deng Jun, E-mail: jun.deng@yale.edu [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States); Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States)

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  4. Absolute and relative dose-surface and dose-volume histograms of the bladder: which one is the most representative for the actual treatment?

    International Nuclear Information System (INIS)

    Hoogeman, Mischa S; Peeters, Stephanie T H; Bois, Josien de; Lebesque, Joos V

    2005-01-01

    The purpose of this study was to quantify to what extent relative and absolute bladder dose-volume and dose-surface histograms of the planning CT scan were representative for the actual treatment. We used data of 17 patients, who each received 11 repeat CT scans and a planning CT scan. The repeat CT scans were matched on the planning CT scan by the bony anatomy. Clinical treatment plans were used to evaluate the impact of bladder filling changes on the four histogram types. The impact was quantified by calculating for this patient group the correlation coefficient between the planning histogram and the treatment histogram. We found that the absolute dose-surface histogram was the most representative one for the actual treatment

  5. High-Dose Opioid Prescribing and Opioid-Related Hospitalization: A Population-Based Study.

    Directory of Open Access Journals (Sweden)

    Kimberly Fernandes

    Full Text Available To examine the impact of national clinical practice guidelines and provincial drug policy interventions on prevalence of high-dose opioid prescribing and rates of hospitalization for opioid toxicity.Interventional time-series analysis.Ontario, Canada, from 2003 to 2014.Ontario Drug Benefit (ODB beneficiaries aged 15 to 64 years from 2003 to 2014.Publication of Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain (May 2010 and implementation of Ontario's Narcotics Safety and Awareness Act (NSAA; November 2011.Three outcomes were explored: the rate of opioid use among ODB beneficiaries, the prevalence of opioid prescriptions exceeding 200 mg and 400 mg morphine equivalents per day, and rates of opioid-related emergency department visits and hospital admissions.Over the 12 year study period, the rate of opioid use declined 15.2%, from 2764 to 2342 users per 10,000 ODB eligible persons. The rate of opioid use was significantly impacted by the Canadian clinical practice guidelines (p-value = .03 which led to a decline in use, but no impact was observed by the enactment of the NSAA (p-value = .43. Among opioid users, the prevalence of high-dose prescribing doubled (from 4.2% to 8.7% over the study period. By 2014, 40.9% of recipients of long-acting opioids exceeded daily doses of 200 mg morphine or equivalent, including 55.8% of long-acting oxycodone users and 76.3% of transdermal fentanyl users. Moreover, in the last period, 18.7% of long-acting opioid users exceeded daily doses of 400 mg morphine or equivalent. Rates of opioid-related emergency department visits and hospital admissions increased 55.0% over the study period from 9.0 to 14.0 per 10,000 ODB beneficiaries from 2003 to 2013. This rate was not significantly impacted by the Canadian clinical practice guidelines (p-value = .68 or enactment of the NSAA (p-value = .59.Although the Canadian clinical practice guidelines for use of opioids in chronic non

  6. Gastrointestinal toxicity and its relation to dose distributions in the anorectal region of prostate cancer patients treated with radiotherapy

    International Nuclear Information System (INIS)

    Heemsbergen, Wilma D.; Hoogeman, Mischa S.; Hart, Guus A.M.; Lebesque, Joos V.; Koper, Peter C.M.

    2005-01-01

    Purpose: To study the correlations between the dose distributions in the anorectal region and late GI symptoms in patients treated for localized prostate carcinoma. Methods and materials: Data from a randomized study were analyzed. In this trial, patients were treated with either rectangular or conformal fields with a dose of 66 Gy. Data concerning GI symptoms were collected from questionnaires of 197 patients. The distributions of the anorectal region were projected on maps, and the dose parameters were calculated. The incidences of complaints were studied as a function of the dose-area parameters and clinical parameters, using a proportional hazard regression model. Finally, we tested a series of dose parameters originating from different parts of the anorectal region. Results: Analyzing the total region, only a statistically significant dose-area effect relation for bleeding was found (p < 0.01). Defining subareas, we found effect relations for bleeding, soiling, fecal incontinence, and mucus loss. For bleeding and mucus loss, the strongest correlation was found for the dose received by the upper 70-80% of the anorectal region (p < 0.01). For soiling and fecal incontinence, we found the strongest association with the dose to the lower 40-50% (p < 0.05). Conclusion: We found evidence that complaints originate from specific regions of the irradiated lower GI tract. Bleeding and mucus loss are probably related to irradiation of the upper part of the rectum. Soiling and fecal incontinence are more likely related to the dose to the anal canal and the lower part of the rectum

  7. 210Pb and 210Po in Venice Lagoon Biota and their contribution to population dose

    International Nuclear Information System (INIS)

    Jia Guogang; Rosamilia, S.; Blasi, M.; Sansone, U.; Belli, M.; Sepulcri, D.; Bidoli, P.

    2002-01-01

    Phosphogypsum is a by-product resulting from the processes applied in phosphoric acid or phosphate fertilizer production. The phosphate ore used in these chemical processes contains the naturally occurring radioactive materials U, and Th, along with their decay products. Large volumes of solid waste products were discharged from a phosphoric acid production plant on the edge of the Venice lagoon (Italy). Water, suspended matter, and biota were monitored in the Venice lagoon, since this aquatic environment can be considered to represent the final area of deposition for the radionuclides transported from inland. The present paper reports data on the activity concentrations of 210 Po and 210 Pb determined in biota living in the lagoon, and an estimation of the contribution to internal dose to man from the ingestion of food originating in the investigated area. (orig.)

  8. Modeling gamma radiation dose in dwellings due to building materials.

    Science.gov (United States)

    de Jong, Peter; van Dijk, Willem

    2008-01-01

    A model is presented that calculates the absorbed dose rate in air of gamma radiation emitted by building materials in a rectangular body construction. The basis for these calculations is formed by a fixed set of specific absorbed dose rates (the dose rate per Bq kg(-1) 238U, 232Th, and 40K), as determined for a standard geometry with the dimensions 4 x 5 x 2.8 m3. Using the computer codes Marmer and MicroShield, correction factors are assessed that quantify the influence of several room and material related parameters on the specific absorbed dose rates. The investigated parameters are the position in the construction; the thickness, density, and dimensions of the construction parts; the contribution from the outer leave; the presence of doors and windows; the attenuation by internal partition walls; the contribution from building materials present in adjacent rooms; and the effect of non-equilibrium due to 222Rn exhalation. To verify the precision, the proposed method is applied to three Dutch reference dwellings, i.e., a row house, a coupled house, and a gallery apartment. The averaged difference with MCNP calculations is found to be 4%.

  9. Dose Relations between Goal Setting, Theory-Based Correlates of Goal Setting and Increases in Physical Activity during a Workplace Trial

    Science.gov (United States)

    Dishman, Rod K.; Vandenberg, Robert J.; Motl, Robert W.; Wilson, Mark G.; DeJoy, David M.

    2010-01-01

    The effectiveness of an intervention depends on its dose and on moderators of dose, which usually are not studied. The purpose of the study is to determine whether goal setting and theory-based moderators of goal setting had dose relations with increases in goal-related physical activity during a successful workplace intervention. A…

  10. Effective dose rate coefficients for exposure to contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K.G. [Easterly Scientific, Knoxville, TN (United States); Y-12 National Security Complex, Oak Ridge, TN (United States); Eckerman, K.F.; Easterly, C.E. [Easterly Scientific, Knoxville, TN (United States); Bellamy, M.B.; Hiller, M.M.; Dewji, S.A. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Hertel, N.E. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Georgia Institute of Technology, Atlanta, GA (United States); Manger, R. [University of California San Diego, Department of Radiation Medicine and Applied Sciences, La Jolla, CA (United States)

    2017-08-15

    The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios. (orig.)

  11. Study of the anti-inflammatory effects of low-dose radiation. The contribution of biphasic regulation of the antioxidative system in endothelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Large, Martin; Hehlgans, Stephanie; Reichert, Sebastian; Roedel, Claus; Roedel, Franz [Goethe University Frankfurt, Department of Radiotherapy and Oncology, Frankfurt am Main (Germany); Gaipl, Udo S. [University Hospital Erlangen, Department of Radiation Oncology, Erlangen (Germany); Fournier, Claudia [GSI Helmholtz Center for Heavy Ion Research, Department of Biophysics, Darmstadt (Germany); Weiss, Christian [Goethe University Frankfurt, Department of Radiotherapy and Oncology, Frankfurt am Main (Germany); Klinikum Darmstadt, Institute for Radiooncology and Radiotherapy, Darmstadt (Germany)

    2015-09-15

    We examined (a) the expression of the antioxidative factor glutathione peroxidase (GPx) and the transcription factor nuclear factor E2-related factor 2 (Nrf2) following low-dose X-irradiation in endothelial cells (ECs) and (b) the impact of reactive oxygen species (ROS) and Nrf2 on functional properties of ECs to gain further knowledge about the anti-inflammatory mode of action of low doses of ionizing radiation. EA.hy926 ECs and primary human dermal microvascular ECs (HMVEC) were stimulated by tumor necrosis factor-α (TNF-α, 20 ng/ml) 4 h before irradiation with single doses ranging from 0.3 to 3 Gy. The expression and activity of GPx and Nrf2 were analyzed by flow cytometry, colorimetric assays, and real-time PCR. The impact of ROS and Nrf2 on peripheral blood mononuclear cell (PBMC) adhesion was assayed in the presence of the ROS scavenger N-acetyl-L-cysteine (NAC) and Nrf2 activator AI-1. Following a low-dose exposure, we observed in EA.hy926 EC and HMVECs a discontinuous expression and enzymatic activity of GPx concomitant with a lowered expression and DNA binding activity of Nrf2 that was most pronounced at a dose of 0.5 Gy. Scavenging of ROS by NAC and activation of Nrf2 by AI-1 significantly diminished a lowered adhesion of PBMC to EC at a dose of 0.5 Gy. Low-dose irradiation resulted in a nonlinear expression and activity of major compounds of the antioxidative system that might contribute to anti-inflammatory effects in stimulated ECs. (orig.) [German] Ziel der Studie war die Untersuchung der Expression des antioxidativen Enzyms Glutathionperoxidase (GPx) und des Transkriptionsfaktors ''nuclear factor E2-related factor 2'' (Nrf2) in Endothelzellen nach niedrigdosierter Roentgenbestrahlung. Des Weiteren wurde der Einfluss von reaktiven Sauerstoffmetaboliten (ROS) und von Nrf2 auf funktionelle Eigenschaften von Endothelzellen analysiert, um weitere Erkenntnisse ueber die antientzuendliche Wirkung von niedrigdosierten Roentgenstrahlen

  12. Management of pediatric radiation dose using Fuji computed radiography

    International Nuclear Information System (INIS)

    MacCutcheon, D.W.

    2004-01-01

    This paper describes the technical details of Fuji Computed Radiography (FCR) and its use as it relates to managing pediatric dose for X-ray examinations. Since its introduction in 1983, Fuji (Fuji Photo Film Co., Ltd.) has developed an extensive set of menu selections with default processing algorithms and corresponding display processing parameters modified for all pediatric exam types. Continued development of imaging plate technology, FCR reader design and image processing have all contributed to improving image quality and creating the opportunity to lower the dose required for pediatric exams. Fuji continues to advance CR and electronic imaging technologies; some of these developments, that may enable lower dose examinations for pediatric imaging in the future, are also described in this paper. (orig.)

  13. Plain radiography procedures in Sudan: examination frequency and collective dose

    International Nuclear Information System (INIS)

    Musa, B. E. Y.

    2010-12-01

    According to the previous studies diagnostic examinations are the largest man-made source to collective dose (CED) in world. It was observed that, despite of the large number of medical x-ray installations in Sudan and in particular conventional x-ray procedures, studies aimed at estimating collective effective dose in diagnostic radiology were lacking. The purpose of this study was to estimate the annual frequency of plain radiography examinations and to estimate the annual collective effective dose to Sudanese population due to plain radiography examinations, selected by their high frequencies or their relatively high doses delivered to patient. To have an idea about the typical examinations frequencies, data were collected from a sample of ten hospitals in Khartoum. The collected data provided information about the x-ray machine manufacture, year of installation and frequency of some examinations per day. The annual collective doses from all medical examinations to the population are: 441, 166, 630, 544, 276, 525, 30, 9, 12 and 161 man Sv from abdomen AP, chest AP, pelvis, lumbar spine PA, lumbar spain PA, lumbar- sacral joints, Skull AP, Skull LAT, Skull PA and from others examination, respectively. The resulting annual collective effective dose was evaluated 2793 man Sv, with the largest contribution of pelvis and LS examinations and lowest contribution of skull examinations. Collective effective dose resulting from the use of plain radiography examinations in the Sudan is small compared with global results. But that dose not negate the need to conduct radiological surveys in frequent intervals to meet the increase of successive x-ray equipment to try to estimate and reduce the doses of patients and the public. (Author)

  14. Radiation Dose from Reentrant Electrons

    Science.gov (United States)

    Badhwar, G.D.; Cleghorn, T. E.; Watts, J.

    2003-01-01

    In estimating the crew exposures during an EVA, the contribution of reentrant electrons has always been neglected. Although the flux of these electrons is small compared to the flux of trapped electrons, their energy spectrum extends to several GeV compared to about 7 MeV for trapped electrons. This is also true of splash electrons. Using the measured reentrant electron energy spectra, it is shown that the dose contribution of these electrons to the blood forming organs (BFO) is more than 10 times greater than that from the trapped electrons. The calculations also show that the dose-depth response is a very slowly changing function of depth, and thus adding reasonable amounts of additional shielding would not significantly lower the dose to BFO.

  15. beta- and gamma-Comparative dose estimates on Eniwetok Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L.

    1982-05-01

    Eniwetok Atoll is one of the Pacific atolls used for atmospheric testing of U.S. nuclear weapons. Beta dose and gamma-ray exposure measurements were made on two islands of the Eniwetok Atoll during July-August 1976 to determine the beta and low energy gamma-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a beta-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to beta- or low energy gamma-contribution. The contribution at any particular site, however, is somewhat dependent on ground cover, since a minimal amount of vegetation will reduce it significantly from that over bare soil, but thick stands of vegetation have little effect on any further reductions. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey (En73). Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the beta's or low energy gamma's, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  16. Study of dose and relative risk of occupationally exposed individuals in interventional procedures

    International Nuclear Information System (INIS)

    Silveira Filho, Jose A.M.; Reis, Charlene O.; Taniguti, Lana T.; Pacifico, Leonardo C.; SaintYves, Thalis L.A.; Mecca, Fernando A.

    2012-01-01

    This paper estimates the occupational effective dose and the relative risk of leukemia and cancers of the digestive tract mortality through dose study of the most radiosensitive anatomical regions (lens, thyroid, chest and gonads) of the professionals involved in interventional gonad procedures. It was considered a cumulative exposure time of 10,000 hours, which is the occupational exposure time of an IOE in throughout his professional life. It was also considered that they always use Personal Protective Equipment (PPE). Mathematical models derived from epidemiological data contained in the BEIR V and in the IAEA’s TECDOC 870 are used to estimate the relative risk. The results show a significant increase in mortality risk for these types of cancer for individuals occupationally exposed to three different distances from the x-ray beam, and reinforces that radiation protection measures are essential. (author)

  17. Proximity correction of high-dosed frame with PROXECCO

    Science.gov (United States)

    Eisenmann, Hans; Waas, Thomas; Hartmann, Hans

    1994-05-01

    Usefulness of electron beam lithography is strongly related to the efficiency and quality of methods used for proximity correction. This paper addresses the above issue by proposing an extension to the new proximity correction program PROXECCO. The combination of a framing step with PROXECCO produces a pattern with a very high edge accuracy and still allows usage of the fast correction procedure. Making a frame with a higher dose imitates a fine resolution correction where the coarse part is disregarded. So after handling the high resolution effect by means of framing, an additional coarse correction is still needed. Higher doses have a higher contribution to the proximity effect. This additional proximity effect is taken into account with the help of the multi-dose input of PROXECCO. The dose of the frame is variable, depending on the deposited energy coming from backscattering of the proximity. Simulation proves the very high edge accuracy of the applied method.

  18. Clinical experience with fixed bimonthly aflibercept dosing in treatment-experienced patients with neovascular age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Khanani AM

    2015-07-01

    Full Text Available Arshad M Khanani Sierra Eye Associates, Reno, NV, USA Purpose: To evaluate the durability of fixed bimonthly dosing of intravitreal aflibercept for neovascular age-related macular degeneration.Methods: Records of 16 patients were retrospectively reviewed. Patients received three initial 2.0 mg monthly doses of aflibercept then 8-weekly doses according to the product label. Best-corrected visual acuity (Early Treatment Diabetic Retinopathy Study [ETDRS] letters, central macular thickness, fluid on optical coherence tomography, and pigment epithelial detachment (PED were measured.Results: Prior to starting aflibercept, 13 patients had subretinal fluid (SRF, five had intraretinal fluid (IRF, four had PED, and baseline visual acuity (VA was 62 approximate ETDRS letters. Following the monthly dosing, seven patients had no improvement or decreased VA, ten patients still had SRF/IRF, and PED had worsened in one patient. At Visit 4, an average of 6.8 weeks after Visit 3, VA had decreased in seven patients, SRF/IRF had increased in 12 patients, and PED had returned in all patients who initially responded. Based on the presence of fluid after the initial monthly injections, 12 patients could not be extended to fixed bimonthly dosing.Conclusion: This case series adds to the growing body of evidence on the need for flexible dosing schedules for the personalized treatment of neovascular age-related macular degeneration. Keywords: age-related macular degeneration, AMD, bimonthly, regimen, aflibercept, case studies, retinal fluid

  19. Multidisciplinary European Low Dose Initiative (MELODI). Strategic research agenda for low dose radiation risk research

    Energy Technology Data Exchange (ETDEWEB)

    Kreuzer, M. [Federal Office for Radiation Protection, BfS, Department of Radiation Protection and Health, Neuherberg (Germany); Auvinen, A. [University of Tampere, Tampere (Finland); STUK, Helsinki (Finland); Cardis, E. [ISGlobal, Barcelona Institute for Global Health, Barcelona (Spain); Durante, M. [Institute for Fundamental Physics and Applications, TIFPA, Trento (Italy); Harms-Ringdahl, M. [Stockholm University, Centre for Radiation Protection Research, Stockholm (Sweden); Jourdain, J.R. [Institute for Radiological Protection and Nuclear Safety, IRSN, Fontenay-aux-roses (France); Madas, B.G. [MTA Centre for Energy Research, Environmental Physics Department, Budapest (Hungary); Ottolenghi, A. [University of Pavia, Physics Department, Pavia (Italy); Pazzaglia, S. [Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome (Italy); Prise, K.M. [Queens University Belfast, Belfast (United Kingdom); Quintens, R. [Belgian Nuclear Research Centre, SCK-CEN, Mol (Belgium); Sabatier, L. [French Atomic Energy Commission, CEA, Paris (France); Bouffler, S. [Public Health England, PHE, Chilton (United Kingdom)

    2018-03-15

    MELODI (Multidisciplinary European Low Dose Initiative) is a European radiation protection research platform with focus on research on health risks after exposure to low-dose ionising radiation. It was founded in 2010 and currently includes 44 members from 18 countries. A major activity of MELODI is the continuous development of a long-term European Strategic Research Agenda (SRA) on low-dose risk for radiation protection. The SRA is intended to identify priorities for national and European radiation protection research programs as a basis for the preparation of competitive calls at the European level. Among those key priorities is the improvement of health risk estimates for exposures close to the dose limits for workers and to reference levels for the population in emergency situations. Another activity of MELODI is to ensure the availability of European key infrastructures for research activities, and the long-term maintenance of competences in radiation research via an integrated European approach for training and education. The MELODI SRA identifies three key research topics in low dose or low dose-rate radiation risk research: (1) dose and dose rate dependence of cancer risk, (2) radiation-induced non-cancer effects and (3) individual radiation sensitivity. The research required to improve the evidence base for each of the three key topics relates to three research lines: (1) research to improve understanding of the mechanisms contributing to radiogenic diseases, (2) epidemiological research to improve health risk evaluation of radiation exposure and (3) research to address the effects and risks associated with internal exposures, differing radiation qualities and inhomogeneous exposures. The full SRA and associated documents can be downloaded from the MELODI website (http://www.melodi-online.eu/sra.html). (orig.)

  20. Effective doses in paediatric radiology

    International Nuclear Information System (INIS)

    Iacob, Olga; Diaconescu, Cornelia; Roca, Antoaneta

    2001-01-01

    Because of their longer life expectancy, the risk of late manifestations of detrimental radiation effects is greater in children than in adults and, consequently, paediatric radiology gives ground for more concern regarding radiation protection than radiology of adults. The purpose of our study is to assess in terms of effective doses the magnitude of paediatric patient exposure during conventional X-ray examinations, selected for their high frequency or their relatively high doses to the patient. Effective doses have been derived from measurements of dose-area product (DAP) carried out on over 900 patients undergoing X-ray examinations, in five paediatric units. The conversion coefficients for estimating effective doses are those calculated by the NRPB using Monte-Carlo technique on a series of 5 mathematical phantoms representing 0, 1, 5, 10 and 15 year old children. The annual frequency of X-ray examinations necessary for collective dose calculation are those reported in our last national study on medical exposure, conducted in 1995. The annual effective doses from all medical examinations for the average paediatric patient are as follows: 1.05 mSv for 0 year old, 0.98 mSv for 1 year old, 0.53 mSv for 5 year old, 0.65 mSv for 10 year old and 0.70 mSv for 15 year old. The resulting annual collective effective dose was evaluated at 625 man Sv with the largest contribution of pelvis and hip examinations (34%). The annual collective effective associated with paediatric radiology in Romania represent 5% of the annual value resulting from all diagnostic radiology. Examination of the chest is by far the most frequent procedure for children, accounting for about 60 per cent of all annually performed X-ray conventional examinations. Knowledge of real level of patient dose is an essential component of quality assurance programs in paediatric radiology. (authors)

  1. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  2. Introduction: Issues Related to Dose Units and Damage Correlation

    International Nuclear Information System (INIS)

    Stoller, Roger E.

    2012-01-01

    The observable effects of irradiation on material properties are complex and each such property changed depends sensitively on a range of irradiation and material parameters. This works against development of a universal exposure parameter. The irradiation dose to the material (both ionizing and displacement dose) can be calculated with good accuracy as long as the relevant reaction cross sections are known and implemented in the codes used. This suggests that a focus on dose calculations is warranted. When assessing damage correlation parameters, it is important to determine the appropriate dose parameter first. Then a clear distinction between damage formation and damage accumulation needs to be kept in mind. The dose unit is most helpful for estimating the primary damage generation, e.g. how damage energy is used to estimate atomic displacements. However, damage accumulation requires longer times and involves kinetic and thermodynamic processes that cannot be accounted for in a dose or primary damage unit. The adequacy of the primary damage formulations can be assessed through their use in mean field reaction rate theory or kinetic Monte Carlo microstructural evolution models to predict damage accumulation. The results of these models can be directly compared with experimental observations. (author)

  3. Basic dose response of fluorescent screen-based portal imaging device

    International Nuclear Information System (INIS)

    Yeo, In Hwan; Yonannes, Yonas; Zhu, Yunping

    1999-01-01

    The purpose of this study is to investigate fundamental aspects of the dose response of fluorescent screen-based electronic portal imaging devices (EPIDs). We acquired scanned signal across portal planes as we varied the radiation that entered the EPID by changing the thickness and anatomy of the phantom as well as the air gap between the phantom and the EPID. In addition, we simulated the relative contribution of the scintillation light signal in the EPID system. We have shown that the dose profile across portal planes is a function of the air gap and phantom thickness. We have also found that depending on the density change within the phantom geometry, errors associated with dose response based on the EPID scan can be as high as 7%. We also found that scintillation light scattering within the EPID system is an important source of error. This study revealed and demonstrated fundamental characteristics of dose response of EPID, as relative to that of ion chambers. This study showed that EPID based on fluorescent screen cannot be an accurate dosimetry system

  4. Dose evaluation and protection of cosmic radiation

    International Nuclear Information System (INIS)

    Iwai, Satoshi; Takagi, Toshiharu

    2004-01-01

    This paper explained the effects of cosmic radiation on aircraft crews and astronauts, as well as related regulations. International Commission on Radiological Protection (ICRP) recommends the practice of radiation exposure management for the handling/storage of radon and materials containing natural radioactive substances, as well as for boarding jet aircraft and space flight. Common aircraft crew members are not subject to radiation exposure management in the USA and Japan. In the EU, the limit value is 6 mSv per year, and for the crew group exceeding this value, it is recommended to keep records containing appropriate medical examination results. Pregnant female crewmembers are required to keep an abdominal surface dose within 1 mSv. For astronauts, ICRP is in the stage of thinking about exposure management. In the USA, National Council on Radiation Protection and Measurement has set dose limits for 30 days, 1 year, and lifetime, and recommends lifetime effective dose limits against carcinogenic risk for each gender and age group. This is the setting of the dose limits so that the risk of carcinogenesis, to which space radiation exposure is considered to contribute, will reach 3%. For cosmic radiation environments at spacecraft inside and aircraft altitude, radiation doses can be calculated for astronauts and crew members, using the calculation methods for effective dose and dose equivalent for tissue. (A.O.)

  5. Trends in population dose and examples of occupational dose reduction

    International Nuclear Information System (INIS)

    Shaw, K.B.; Hughes, J.S.; McDonough, L.; Gelder, R.

    1989-01-01

    The recent review by NRPB of the exposure of the UK population shows the average annual dose to the population from all sources of radiation to be 2.5 mSv(1). Natural radiation gives rise to 87% of this with radon daughters accounting for the largest single contribution of 1.2 mSv. Medical irradiation remains the most significant contributor to the dose from man-made sources: the current estimate for all diagnostic uses is 0.3 mSv per annum. (author)

  6. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  7. An environmental dose experiment

    Science.gov (United States)

    Peralta, Luis

    2017-11-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained.

  8. An environmental dose experiment

    International Nuclear Information System (INIS)

    Peralta, Luis

    2017-01-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained. (paper)

  9. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ehlerman, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    2001-03-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  10. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    International Nuclear Information System (INIS)

    Ehlerman, D.A.E.

    2001-01-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  11. Short-term, high-dose glucocorticoid treatment does not contribute to reduced bone mineral density in patients with multiple sclerosis.

    Science.gov (United States)

    Olsson, A; Oturai, D B; Sørensen, P S; Oturai, P S; Oturai, A B

    2015-10-01

    Patients with multiple sclerosis (MS) are at increased risk of reduced bone mineral density (BMD). A contributing factor might be treatment with high-dose glucocorticoids (GCs). The objective of this paper is to assess bone mass in patients with MS and evaluate the importance of short-term, high-dose GC treatment and other risk factors that affect BMD in patients with MS. A total of 260 patients with MS received short-term high-dose GC treatment and had their BMD measured by dual x-ray absorptiometry. BMD was compared to a healthy age-matched reference population (Z-scores). Data regarding GCs, age, body mass index (BMI), serum 25(OH)D, disease duration and severity were collected retrospectively and analysed in a multiple linear regression analysis to evaluate the association between each risk factor and BMD. Osteopenia was present in 38% and osteoporosis in 7% of the study population. Mean Z-score was significantly below zero, indicating a decreased BMD in our MS patients. Multiple linear regression analysis showed no significant association between GCs and BMD. In contrast, age, BMI and disease severity were independently associated with both lumbar and femoral BMD. Reduced BMD was prevalent in patients with MS. GC treatment appears not to be the primary underlying cause of secondary osteoporosis in MS patients. © The Author(s), 2015.

  12. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.

    1996-09-01

    A preliminary radiological dose assessment of equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials (NORM) in production waste streams. The assessment estimated maximum individual dose equivalents for workers and the general public. Sensitivity analyses of certain input parameters also were conducted. On the basis of this assessment, it is concluded that (1) regulations requiring workers to wear respiratory protection during equipment cleaning operations are likely to result in lower worker doses, (2) underground injection and downhole encapsulation of NORM wastes present a negligible risk to the general public, and (3) potential doses to workers and the general public related to smelting NORM-contaminated equipment can be controlled by limiting the contamination level of the initial feed. It is recommended that (1) NORM wastes be further characterized to improve studies of potential radiological doses; (2) states be encouraged to permit subsurface disposal of NORM more readily, provided further assessments support this study; results; (3) further assessment of landspreading NORM wastes be conducted; and (4) the political, economic, sociological, and nonradiological issues related to smelting NORM-contaminated equipment be studied to fully examine the feasibility of this disposal option

  13. An analysis of ingestion doses from a range of postulated Magnox reactor releases

    International Nuclear Information System (INIS)

    Nair, S.

    1986-01-01

    An analysis was carried out of ingestion doses from a range of postulated Magnox reactor releases to the atmosphere. Doses to the adult, ten year old child and one year old child were calculated, which showed the one year old child to receive the highest dose. Detailed studies were made of the significance of the ingestion dose to the one year old child in relation to other exposure routes. The ingestion dose was analysed for its contributing critical organs, foods and nuclides. Approximate calculations were also made of the dependence of the ingestion dose on the time of year when the release occurs. The ingestion pathway was found to dominate if the release occurs towards the end of the growing season but to be less significant relative to other exposure pathways at all other times. The calculations enabled a set of release-specific emergency action guidance levels of critical nuclide concentrations in the critical foods to be produced, which comply with NRPB's ingestion Emergency Reference Level guidelines. (author)

  14. Measurement of relative depth-dose distribution in radiochromic film dosimeters irradiated with 43-70 keV electron beam for industrial application

    Science.gov (United States)

    Matsui, Shinjiro; Hattori, Takeaki; Nonaka, Takashi; Watanabe, Yuki; Morita, Ippei; Kondo, Junichi; Ishikawa, Masayoshi; Mori, Yoshitaka

    2018-05-01

    The relative dose in a layer, which is thinner than the thickness of the dosimeter is evaluated using simulated depth-dose distributions, and the measured responses of dosimeters with acceleration voltages from 43 to 70 kV, via ultra-low-energy electron beam (ULEB) irradiation. By stacking thin film dosimeters, we confirmed that the simulated depth-dose distributions coincided with the measured depth-dose curve within the measurement uncertainty (k = 2). Using the measurement dose of the 47 μm dosimeter and the simulated depth-dose distribution, the dose of 11 μm dosimeters in the surface was evaluated within the measurement uncertainty (k = 2). We also verified the effectiveness of this method for a thinner layer by changing the acceleration voltage of the irradiation source. We evaluated the relative dose for an adjusted depth of energy deposition from 4.4 μm to 22.8 μm. As a result, this method was found to be effective for a thickness, which is less than the thickness of the dosimeter. When irradiation conditions are well known with accuracy, using the confirmed relative depth-dose distributions across any dosimeter thickness range, a dose evaluation, in several μm steps will possibly improve the design of industrial ULEB processes.

  15. Salmeterol/fluticasone stable-dose treatment compared with formoterol/budesonide adjustable maintenance dosing: impact on health-related quality of life

    Directory of Open Access Journals (Sweden)

    Williams Angela E

    2007-07-01

    Full Text Available Abstract Background Improving patients' health-related quality of life (HRQoL is recognized as a fundamental part of asthma management. The aims of this study were to evaluate the long-term efficacy (including symptom-free days and exacerbations and impact on HRQoL of a stable-dose regimen of salmeterol/fluticasone propionate (SAL/FP and an adjustable maintenance dosing (AMD regimen of formoterol/budesonide (FOR/BUD where treatment is adjusted based on symptoms [SAM40056]. Methods A total of 688 outpatients with asthma receiving regular low-dose inhaled corticosteroids (ICS plus a long-acting β2-agonist, or medium dose ICS alone participated in this randomized, double-blind, double-dummy, parallel-group, 1-year trial, which was conducted in 91 centers in 15 countries. Patients were randomized to receive 1 inhalation of SAL/FP 50/250 μg BID or 2 inhalations of FOR/BUD 6/200 μg BID during Weeks 1–4. For Weeks 5–52, patients meeting strict continuation criteria for stable asthma at Week 4 received AMD with FOR/BUD or stable-dose SAL/FP. Results The percentage of symptom-free days was significantly greater (58.8% vs 52.1%; p = 0.034 and the annual exacerbation rate was significantly lower (47%; p = 0.008 with stable-dose SAL/FP compared with FOR/BUD AMD. A total of 568 patients completed the Asthma Quality of Life Questionnaire (AQLQ at least once during the study. The mean change from baseline in AQLQ overall score was numerically greater with SAL/FP than FOR/BUD at week 28 and week 52, but did not reach statistical significance (p = 0.121 at Week 52. However, in a post hoc logistic regression analyses for any AQLQ improvement, significant benefits with SAL/FP were seen at both time points (p = 0.038 and p = 0.009, respectively. The minimally important difference of ≥ 0.5-point improvement in AQLQ overall score was achieved by a significantly greater number of patients receiving SAL/FP at Week 28 (68% vs 60%; p = 0.049; a trend for this

  16. Variable effects of high-dose adrenaline relative to standard-dose adrenaline on resuscitation outcomes according to cardiac arrest duration.

    Science.gov (United States)

    Jeung, Kyung Woon; Ryu, Hyun Ho; Song, Kyung Hwan; Lee, Byung Kook; Lee, Hyoung Youn; Heo, Tag; Min, Yong Il

    2011-07-01

    Adjustment of adrenaline (epinephrine) dosage according to cardiac arrest (CA) duration, rather than administering the same dose, may theoretically improve resuscitation outcomes. We evaluated variable effects of high-dose adrenaline (HDA) relative to standard-dose adrenaline (SDA) on resuscitation outcomes according to CA duration. Twenty-eight male domestic pigs were randomised to the following 4 groups according to the dosage of adrenaline (SDA 0.02 mg/kg vs. HDA 0.2mg/kg) and duration of CA before beginning cardiopulmonary resuscitation (CPR): 6 min SDA, 6 min HDA, 13 min SDA, or 13 min HDA. After the predetermined duration of untreated ventricular fibrillation, CPR was provided. All animals in the 6 min SDA, 6 min HDA, and 13 min HDA groups were successfully resuscitated, while only 4 of 7 pigs in the 13 min SDA group were successfully resuscitated (p=0.043). HDA groups showed higher right atrial pressure, more frequent ventricular ectopic beats, higher blood glucose, higher troponin-I, and more severe metabolic acidosis than SDA groups. Animals of 13 min groups showed more severe metabolic acidosis and higher troponin-I than animals of 6 min groups. All successfully resuscitated animals, except two animals in the 13 min HDA group, survived for 7 days (p=0.121). Neurologic deficit score was not affected by the dose of adrenaline. HDA showed benefit in achieving restoration of spontaneous circulation in 13 min CA, when compared with 6 min CA. However, this benefit did not translate into improved long-term survival or neurologic outcome. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Effective dose range for dental cone beam computed tomography scanners

    International Nuclear Information System (INIS)

    Pauwels, Ruben; Beinsberger, Jilke; Collaert, Bruno; Theodorakou, Chrysoula; Rogers, Jessica; Walker, Anne; Cockmartin, Lesley; Bosmans, Hilde; Jacobs, Reinhilde; Bogaerts, Ria; Horner, Keith

    2012-01-01

    Objective: To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. Materials and methods: Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100H) which were evenly distributed throughout the head and neck, covering all radiosensitive organs. Measurements were performed on 14 CBCT devices: 3D Accuitomo 170, Galileos Comfort, i-CAT Next Generation, Iluma Elite, Kodak 9000 3D, Kodak 9500, NewTom VG, NewTom VGi, Pax-Uni3D, Picasso Trio, ProMax 3D, Scanora 3D, SkyView, Veraviewepocs 3D. Effective dose was calculated using the ICRP 103 (2007) tissue weighting factors. Results: Effective dose ranged between 19 and 368 μSv. The largest contributions to the effective dose were from the remainder tissues (37%), salivary glands (24%), and thyroid gland (21%). For all organs, there was a wide range of measured values apparent, due to differences in exposure factors, diameter and height of the primary beam, and positioning of the beam relative to the radiosensitive organs. Conclusions: The effective dose for different CBCT devices showed a 20-fold range. The results show that a distinction is needed between small-, medium-, and large-field CBCT scanners and protocols, as they are applied to different indication groups, the dose received being strongly related to field size. Furthermore, the dose should always be considered relative to technical and diagnostic image quality, seeing that image quality requirements also differ for patient groups. The results from the current study indicate that the optimisation of dose should be performed by an appropriate selection of exposure parameters and field size, depending on the diagnostic requirements.

  18. Multi-walled carbon nanotubes: A cytotoxicity study in relation to functionalization, dose and dispersion.

    Science.gov (United States)

    Zhou, Lulu; Forman, Henry Jay; Ge, Yi; Lunec, Joseph

    2017-08-01

    Chemical functionalization broadens carbon nanotube (CNT) applications, conferring new functions, but at the same time potentially altering toxicity. Although considerable experimental data related to CNT toxicity, at the molecular and cellular levels, have been reported, there is very limited information available for the corresponding mechanism involved (e.g. cell apoptosis and genotoxicity). The threshold dose for safe medical application in relation to both pristine and functionalized carbon nanotubes remains ambiguous. In this study, we evaluated the in vitro cytotoxicity of pristine and functionalized (OH, COOH) multi-walled carbon nanotubes (MWCNTs) for cell viability, oxidant detection, apoptosis and DNA mutations, to determine the non-toxic dose and influence of functional group in a human lung-cancer cell line exposed to 1-1000μg/ml MWCNTs for 24, 48 and 72h. The findings suggest that pristine MWCNTs induced more cell death than functionalized MWCNTs while functionalized MWCNTs are more genotoxic compared to their pristine form. The level of both dose and dispersion in the matrix used should be taken into consideration before applying further clinical applications of MWCNTs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  20. Study on relations between heavy ions single event upset cross sections and γ accumulated doses

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; Wang Yanping; Peng Honglun; Yang Hailiang; Chen Xiaohua; Li Guozheng

    2002-01-01

    Experiments were done under 252 Cf and 60 Co γ source to study the relation between heavy ion Single Event Upset (SEU) cross sections and γ accumulated doses. There was no obvious rule and little influence of γ accumulated doses on SEU cross sections when Static Random Access Memories were in power off mode and static power on mode. In active measuring mode, the SEU cross section increased as the accumulated doses increasing when same data were written in memory cells. If reverse data, such as '55' and 'AA', were written in memory cells during the experiment, the SEU cross sections decreased to the level when memories were not irradiated under 60 Co γ source, even more small. It implied that the influence of γ accumulated doses on SEU cross sections can be set off by this method

  1. Stereotactic targeting and dose verification for age-related macular degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Gertner, Michael; Chell, Erik; Pan, Kuang-Hung; Hansen, Steve; Kaiser, Peter K.; Moshfeghi, Darius M. [Oraya Therapeutics, Inc., Newark, California 94560 (United States); Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, Ohio 44915 (United States); Department of Ophthalmology, Stanford University, Stanford, California 94305 (United States)

    2010-02-15

    Purpose: Validation of the targeting and dose delivery of the IRay low voltage age-related macular degeneration treatment system. Methods: Ten human cadaver eyes were obtained for this study and mounted in the IRay system. Using gel and vacuum, an I-Guide immobilization device was coupled to the eyes and radiochromic film was affixed to the posterior aspect of the globes. Three narrow x-ray beams were delivered through the pars plana to overlap on the predicted nominal fovea. A needle was placed through the center of the film's beam spot and into the eye to register the film and the inner retina. The process was performed three times for each of the ten eyes (30 simulated treatments; 90 individual beams). The globes were dissected to assess the targeting accuracy by measuring the distances from the needles to the fovea. The dose to the fovea was calculated from the radiochromic film. Results: X-ray targeting on the retina averaged 0.6{+-}0.4 mm from the fovea. Repeated treatments on the same eye showed a reproducibility of 0.4{+-}0.4 mm. The optic nerve was safely avoided, with the 90% isodose edge of the beam spot between 0.4 and 2.6 mm from the edge of the optic disk. Measured dose matched that prescribed. Conclusions: This study provides confidence that the IRay, with an average accuracy of 0.6 mm and a precision of 0.4 mm, can reliably treat most AMD lesions centered on the fovea. With the exception of motion, all sources of error are included.

  2. Acute and chronic intakes of fallout radionuclides by Marshallese from nuclear weapons testing at Bikini and Enewetak and related internal radiation doses.

    Science.gov (United States)

    Simon, Steven L; Bouville, André; Melo, Dunstana; Beck, Harold L; Weinstock, Robert M

    2010-08-01

    Annual internal radiation doses resulting from both acute and chronic intakes of all important dose-contributing radionuclides occurring in fallout from nuclear weapons testing at Bikini and Enewetak from 1946 through 1958 have been estimated for the residents living on all atolls and separate reef islands of the Marshall Islands. Internal radiation absorbed doses to the tissues most at risk to cancer induction (red bone marrow, thyroid, stomach, and colon) have been estimated for representative persons of all population communities for all birth years from 1929 through 1968, and for all years of exposure from 1948 through 1970. The acute intake estimates rely on a model using, as its basis, historical urine bioassay data, for members of the Rongelap Island and Ailinginae communities as well as for Rongerik residents. The model also utilizes fallout times of arrival and radionuclide deposition densities estimated for all tests and all atolls. Acute intakes of 63 radionuclides were estimated for the populations of the 20 inhabited atolls and for the communities that were relocated during the testing years for reasons of safety and decontamination. The model used for chronic intake estimates is based on reported whole-body, urine, and blood counting data for residents of Utrik and Rongelap. Dose conversion coefficients relating intake to organ absorbed dose were developed using internationally accepted models but specifically tailored for intakes of particulate fallout by consideration of literature-based evidence to choose the most appropriate alimentary tract absorption fraction (f1) values. Dose estimates were much higher for the thyroid gland than for red marrow, stomach wall, or colon. The highest thyroid doses to adults were about 7,600 mGy for the people exposed on Rongelap; thyroid doses to adults were much lower, by a factor of 100 or more, for the people exposed on the populated atolls of Kwajalein and Majuro. The estimates of radionuclide intake and

  3. The expression and evolution of virulence in multiple infections: the role of specificity, relative virulence and relative dose.

    Science.gov (United States)

    Ben-Ami, Frida; Routtu, Jarkko

    2013-05-03

    Multiple infections of the same host by different strains of the same microparasite species are believed to play a crucial role during the evolution of parasite virulence. We investigated the role of specificity, relative virulence and relative dose in determining the competitive outcome of multiple infections in the Daphnia magna-Pasteuria ramosa host-parasite system. We found that infections by P. ramosa clones (single genotype) were less virulent and produced more spores than infections by P. ramosa isolates (possibly containing multiple genotypes). We also found that two similarly virulent isolates of P. ramosa differed considerably in their within-host competitiveness and their effects on host offspring production when faced with coinfecting P. ramosa isolates and clones. Although the relative virulence of a P. ramosa isolate/clone appears to be a good indicator of its competitiveness during multiple infections, the relative dose may alter the competitive outcome. Moreover, spore counts on day 20 post-infection indicate that the competitive outcome is largely decided early in the parasite's growth phase, possibly mediated by direct interference or apparent competition. Our results emphasize the importance of epidemiology as well as of various parasite traits in determining the outcome of within-host competition. Incorporating realistic epidemiological and ecological conditions when testing theoretical models of multiple infections, as well as using a wider range of host and parasite genotypes, will enable us to better understand the course of virulence evolution.

  4. Image quality and doses on selected studies of conventional radiology in designed hospitals

    International Nuclear Information System (INIS)

    Cardenas Herrera, Juan; Martinez Gonzalez, Alina; Machado Tejeda, Adalberto; Mora Machado, Roxana de la; Pedroso, Luis; Martinez Acosta, Ubaldo; Fiqueroa Garcia, Luisa M.

    2008-01-01

    The medical exposures have a significant contribution to the doses received by the population, although it has been given minor attention than to other exposure forms, despite of existing potentialities of reducing doses to the patients as consequence of these applications. In the last years the scientific community and international organizations have defined requirements to contribute to that the doses to the patients are the minimum ones necessary to achieve their diagnostic objective. The present work gives the results obtained in the evaluation of the image quality and doses for exams of thorax PA, lumbar spine AP and lumbar spine lateral, carried out in 2 university hospitals of Havana, as well as the contribution on this investigation to the establishment of the guidance levels in the country. During the investigation it took as reference for the reference for the evaluation of the image quality of the radiological studies the emitted criteria by European Union. The behavior of these approaches for the case of the thorax studies presented its biggest difficulties with the achievement of the approaches related with the visualization of breathing structures, being the execution percentages lower than the remaining countries of the region. In general the behaviour of the approaches of quality image in the ARCAL project. The behaviour of the image quality approaches are associated to different technical factors. The obtained results of doses for thorax PA are bigger than the recommended International Standards Basics in both hospitals. (author)

  5. Supermarket purchase contributes to nutrition-related non-communicable diseases in urban Kenya

    Science.gov (United States)

    Klasen, Stephan; Nzuma, Jonathan M.; Qaim, Matin

    2017-01-01

    Background While undernutrition and related infectious diseases are still pervasive in many developing countries, the prevalence of non-communicable diseases (NCD), typically associated with high body mass index (BMI), is rapidly rising. The fast spread of supermarkets and related shifts in diets were identified as possible factors contributing to overweight and obesity in developing countries. Potential effects of supermarkets on people’s health have not been analyzed up till now. Objective This study investigates the effects of purchasing food in supermarkets on people’s BMI, as well as on health indicators such as fasting blood glucose (FBG), blood pressure (BP), and the metabolic syndrome. Design This study uses cross-section observational data from urban Kenya. Demographic, anthropometric, and bio-medical data were collected from 550 randomly selected adults. Purchasing food in supermarkets is defined as a binary variable that takes a value of one if any food was purchased in supermarkets during the last 30 days. In a robustness check, the share of food purchased in supermarkets is defined as a continuous variable. Instrumental variable regressions are applied to control for confounding factors and establish causality. Results Purchasing food in supermarkets contributes to higher BMI (+ 1.8 kg/m2) (Psupermarkets also contributes to higher levels of FBG (+ 0.3 mmol/L) (PSupermarkets and their food sales strategies seem to have direct effects on people’s health. In addition to increasing overweight and obesity, supermarkets contribute to nutrition-related NCDs. Effects of supermarkets on nutrition and health can mainly be ascribed to changes in the composition of people’s food choices. PMID:28934333

  6. Patient absorbed radiation doses estimation related to irradiation anatomy

    International Nuclear Information System (INIS)

    Soares, Flavio Augusto Penna; Soares, Amanda Anastacio; Kahl, Gabrielly Gomes

    2014-01-01

    Developed a direct equation to estimate the absorbed dose to the patient in x-ray examinations, using electric, geometric parameters and filtering combined with data from irradiated anatomy. To determine the absorbed dose for each examination, the entrance skin dose (ESD) is adjusted to the thickness of the patient's specific anatomy. ESD is calculated from the estimated KERMA greatness in the air. Beer-Lambert equations derived from power data mass absorption coefficients obtained from the NIST / USA, were developed for each tissue: bone, muscle, fat and skin. Skin thickness was set at 2 mm and the bone was estimated in the central ray of the site, in the anteroposterior view. Because they are similar in density and attenuation coefficients, muscle and fat are treated as a single tissue. For evaluation of the full equations, we chose three different anatomies: chest, hand and thigh. Although complex in its shape, the equations simplify direct determination of absorbed dose from the characteristics of the equipment and patient. The input data is inserted at a single time and total absorbed dose (mGy) is calculated instantly. The average error, when compared with available data, is less than 5% in any combination of device data and exams. In calculating the dose for an exam and patient, the operator can choose the variables that will deposit less radiation to the patient through the prior analysis of each combination of variables, using the ALARA principle in routine diagnostic radiology sector

  7. Accuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.

    Science.gov (United States)

    Yi, Dae Yong; Lee, Kyung Hoon; Park, Sung Bin; Kim, Jee Taek; Lee, Na Mi; Kim, Hyery; Yun, Sin Weon; Chae, Soo Ahn; Lim, In Seok

    Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. Patients (n=475) younger than 10 years who were examined for acute appendicitis were recruited. Subjects were divided into three groups according to the examinations performed: low-dose CT, ultrasonography, and standard-dose CT. Subjects were categorized according to age and body mass index (BMI). Low-dose CT was a contributive tool in diagnosing appendicitis, and it was an adequate method, when compared with ultrasonography and standard-dose CT in terms of sensitivity (95.5% vs. 95.0% and 94.5%, p=0.794), specificity (94.9% vs. 80.0% and 98.8%, p=0.024), positive-predictive value (96.4% vs. 92.7% and 97.2%, p=0.019), and negative-predictive value (93.7% vs. 85.7% and 91.3%, p=0.890). Low-dose CT accurately diagnosed patients with a perforated appendix. Acute appendicitis was effectively diagnosed using low-dose CT in both early and middle childhood. BMI did not influence the accuracy of detecting acute appendicitis on low-dose CT. Low-dose CT is effective and accurate for diagnosing acute appendicitis in childhood, as well as in adolescents and young adults. Additionally, low-dose CT was relatively accurate, irrespective of age or BMI, for detecting acute appendicitis. Therefore, low-dose CT is recommended for assessing children with suspected acute appendicitis. Copyright © 2017. Published by Elsevier Editora Ltda.

  8. Study of sources, dose contribution and control measures of Argon-41 at Kaiga Generating Station

    International Nuclear Information System (INIS)

    Venkata Ramana, K.; Shrikrishna, U.V.; Manojkumar, M.; Ramesh, R.; Madhan, V.; Varadhan, R.S.

    2001-01-01

    Air is used as a medium for cooling calandria vault and thermal shield systems in the earlier Pressurised Heavy Water Reactors (Rajasthan Atomic Power Station and Madras Atomic Power Station) in India. This leads to production of significant quantity of 41 Ar in calandria vault and thermal shield cooling systems due to neutron activation of 40 Ar present in air (∼1% v/v). The presence of 41 Ar in reactor building contributes significant external doses to plant personnel during reactor operation and the release of this radionuclide to the environment result in dose to the public in the vicinity of the plants. An attempt is made to eliminate Argon-41 production in Indian standard Pressurised Heavy Water Reactors (Narora Atomic Power Station, Kakrapar Atomic Power Station, Kaiga Generating Station -1 and 2 and Rajasthan Atomic Power Station-3 and 4), by filling the calandria vault with demineralized water and providing a separate Annulus Gas Monitoring System (AGMS) for detecting leaks from calandria tube or pressure tube using Carbon dioxide as a medium. However, 41 Ar is produced in the Annulus Gas Monitoring System, Primary Heat Transport cover gas system and moderator cover gas system due to ingress of air into the systems during operational transients or due to trace quantity of air present as an impurity in the gases used for the above systems. A study was conducted to identify and quantify the sources of 41 Ar in the work areas. This report brings out the sources of 41 Ar, reasons for 41 Ar production and the results of the measures incorporated to reduce the presence of 41 Ar in the above systems. (author)

  9. Radiation doses from radioactivity in incandescent mantles

    International Nuclear Information System (INIS)

    1985-01-01

    Thorium nitrate is used in the production of incandescent mantles for gas lanterns. In this report dose estimates are given for internal and external exposure that result from the use of the incandescent mantles for gas lanterns. The collective, effective dose equivalent for all users of gas mantles is estimated to be about 100 Sv per annum in the Netherlands. For the population involved (ca. 700,000 persons) this is roughly equivalent to 5% to 10% of the collective dose equivalent associated with exposure to radiation from natural sources. The major contribution to dose estimates comes from inhalation of radium during burning of the mantles. A pessimistic approach results in individual dose estimates for inhalation of up to 0.2 mSv. Consideration of dose consequences in case of a fire in a storage department learns that it is necessary for emergency personnel to wear respirators. It is concluded that the uncontrolled removal of used gas mantles to the environment (soil) does not result in a significant contribution to environmental radiation exposure. (Auth.)

  10. A study on measurement on artificial radiation dose rate using the response matrix method

    International Nuclear Information System (INIS)

    Kidachi, Hiroshi; Ishikawa, Yoichi; Konno, Tatsuya

    2004-01-01

    We examined accuracy and stability of estimated artificial dose contribution which is distinguished from natural background gamma-ray dose rate using Response Matrix method. Irradiation experiments using artificial gamma-ray sources indicated that there was a linear relationship between observed dose rate and estimated artificial dose contribution, when irradiated artificial gamma-ray dose rate was higher than about 2 nGy/h. Statistical and time-series analyses of long term data made it clear that estimated artificial contribution showed almost constant values under no artificial influence from the nuclear power plants. However, variations of estimated artificial dose contribution were infrequently observed due to of rainfall, detector maintenance operation and occurrence of calibration error. Some considerations on the factors to these variations were made. (author)

  11. Contribution of the modulation of intensity and the optimization to deliver a dose adapted to the biological heterogeneities

    International Nuclear Information System (INIS)

    Kubs, F.

    2007-10-01

    The recent progress in functional imaging by Positron Emission Tomography (TEP) opens new perspectives in the delineation of target volumes in radiotherapy. The functional data is major; we can intend to adapt the irradiation doses on the tumor activity (TA) and to perform a dose escalation. Our objectives were (i) to characterize the TEP threshold, by quantifying the uncertainties of the target volume contour according to the lesion size and the threshold contour level, (ii) to set up the geometry suited to perform a high-precision irradiation based on the TA, (iii) to estimate the dosimetric impact of this new protocol and (iv) to verify that dosimetry is perfectly distributed. Three original phantoms were specially created to satisfy the constraints met, as well as two virtual phantoms containing 3 dose levels (dose level 3 = TA). Our results showed the importance of the effect threshold-volume on the planning in radiotherapy. To use this irradiation method, the diameter of 1 cm for the third level was able to be reached. A dose escalation of 20 Gy was possible between the second (70 Gy) and the third level (90 Gy). The dosimetric impact estimated on two real cases was suitable - increase of COIN (conformal index) from 0.6 to 0.8 and decrease of NTCP (normal tissue complication probability) of a factor 5 -. In absolute and relative dosimetry, the clinical tolerances were respected. So all the treatment process, going from the diagnosis with the TEP to reveal the TA, to the patient treatment made beforehand on phantom, and going through the ballistic and the dose calculation, was estimated and validated according to our objective to adapt the irradiation to the biological heterogeneities. However such high doses should be carefully estimated before being prescribed clinically and progress is also expected in imaging, because the minimal size which we can irradiate is on the limit of the resolution TEP. (author)

  12. Annual radiation dose in thermoluminescence dating

    International Nuclear Information System (INIS)

    Li Huhou

    1988-01-01

    The annual radiation dose in thermoluminescence dating has been discussed. The autor gives an entirely new concept of the enviromental radiation in the thermoluminescence dating. Methods of annual dose detemination used by author are dating. Methods of annual dose determination used by author are summed up, and the results of different methods are compared. The emanium escapiug of three radioactive decay serieses in nature has been considered, and several determination methods are described. The contribution of cosmic rays for the annual radiation dose has been mentioned

  13. Annual radiation dose in thermoluminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Huhou, Li [Chinese Academy of Social Sciences, Beijing, BJ (China). Inst. of Archaeology

    1988-11-01

    The annual radiation dose in thermoluminescence dating has been discussed. The autor gives an entirely new concept of the enviromental radiation in the thermoluminescence dating. Methods of annual dose detemination used by author are dating. Methods of annual dose determination used by author are summed up, and the results of different methods are compared. The emanium escapiug of three radioactive decay serieses in nature has been considered, and several determination methods are described. The contribution of cosmic rays for the annual radiation dose has been mentioned.

  14. Radiation dose setting for sterilization of health care items in relation to product microbiological quality

    International Nuclear Information System (INIS)

    Norimah Yusof; Nagi Marsit; Asnah Hassan

    1997-01-01

    Radiation dose of 25 k gray is no longer a generally accepted dose for sterilization. ISO document no. 11137 stated that a manufacturer can decide the dose to sterilize his product depending on the product's microbiological quality (number and type of the contaminants) and the sterility assurance level (SAL) should attain in relation to its usage. Five health care products were selected for the microbiological studies including bio burden counts, identification of most commonly found microorganisms and the radioresistance (D sub 10 value) of the selected isolates. Radiation dose was then determined by two methods, namely Method for Dose Validation of ISO 11137, and calculation based on log survival or population cycle reduction. At a given SAL of 10 sup -6 the radiation sterilization dose obtained by both methods was influenced by microbiological quality of the product. Sterilization dose set by the ISO Method I (Cotton Ball 19.4 kGy, Syringe 20.4 kGy, Suture 15. 0 kGy, Surgical Glove 24.9 kGy and Amnion 17.8 kGy) was higher than the dose calculated according to the log cycle reduction concept in all the products (Cotton Ball 14. 0 kGy, Syringe 15.5 kGy, Suture 11. 6 kGy, Surgical Glove 18. 0 kGy and Amnion 12.6 kGy). The ISO method has limitation on bio products such as amnion and other high valued products which are produced in small number with low bio burden and microorganism spectrum different from those commonly found on medical items

  15. Absorbed dose by thyroid in case of nuclear accidents; Dose absorvida pela tireoide em casos de acidentes nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia; Attie, Marcia Regina Pereira [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil). Dept. de Fisica; Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Amaral, Ademir [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2011-07-01

    Radioisotopes of iodine are produced in abundance in nuclear fission reactions, and great amounts of radioiodine may be released into the environment in case of a nuclear reactor accident. Thyroid gland is among the most radiosensitive organs due to its capacity to concentrate iodine. The aim of this work was to evaluate the importance of contributions of internally deposited iodines ({sup 131}I, {sup 132}I, {sup 133}I, {sup 134}I and {sup 135}I) to the dose absorbed to thyroid follicle and to the whole organ, after internal contamination by those isotopes. For internal dose calculation, the code of particles transport MCNP4C was employed. The results showed that, in case of nuclear accidents, the contribution of short-lived iodines for total dose is about 45% for thyroid of newborn and about 40% for thyroid of adult. Thus, these contributions should not be neglected in a prospective evaluation of risks associated to internal contamination by radioactive iodine. (author)

  16. Two dose investigation of the 5-HT-agonist psilocybin on relative and global cerebral blood flow.

    Science.gov (United States)

    Lewis, Candace R; Preller, Katrin H; Kraehenmann, Rainer; Michels, Lars; Staempfli, Philipp; Vollenweider, Franz X

    2017-10-01

    Psilocybin, the active compound in psychedelic mushrooms, is an agonist of various serotonin receptors. Seminal psilocybin positron emission tomography (PET) research suggested regional increases in glucose metabolism in frontal cortex (hyperfrontality). However, a recent arterial spin labeling (ASL) study suggests psilocybin may lead to hypo-perfusion in various brain regions. In this placebo-controlled, double-blind study we used pseudo-continuous ASL (pCASL) to measure perfusion changes, with and without adjustment for global brain perfusion, after two doses of oral psilocybin (low dose: 0.160 mg/kg; high dose: 0.215 mg/kg) in two groups of healthy controls (n = 29 in both groups, total N = 58) during rest. We controlled for sex and age and used family-wise error corrected p values in all neuroimaging analyses. Both dose groups reported profound subjective drug effects as measured by the Altered States of Consciousness Rating Scale (5D-ASC) with the high dose inducing significantly larger effects in four out of the 11 scales. After adjusting for global brain perfusion, psilocybin increased relative perfusion in distinct right hemispheric frontal and temporal regions and bilaterally in the anterior insula and decreased perfusion in left hemispheric parietal and temporal cortices and left subcortical regions. Whereas, psilocybin significantly reduced absolute perfusion in frontal, temporal, parietal, and occipital lobes, and bilateral amygdalae, anterior cingulate, insula, striatal regions, and hippocampi. Our analyses demonstrate consistency with both the hyperfrontal hypothesis of psilocybin and the more recent study demonstrating decreased perfusion, depending on analysis method. Importantly, our data illustrate that relative changes in perfusion should be understood and interpreted in relation to absolute signal variations. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Contributions of short-lived radioiodines to thyroid doses received by evacuees from the Chernobyl area estimated using early in vivo activity measurements

    International Nuclear Information System (INIS)

    Balonov, M.; Kaidanovsky, G.; Zvonova, I.; Kovtun, A.; Bouville, A.; Luckyanov, L.; Voilleque, P.

    2003-01-01

    A series of in-vivo gamma spectrometric measurements of 65 people, evacuated from Pripyat 1.5 days after the Chernobyl Nuclear Power Plant Unit 4 explosion was performed in St. Petersburg, Russia, as early as 30 April 1986. The historical spectra and interviews were recently processed and the results used for thyroid dose estimation. Activities of 131 I in thyroid and 132 Te in lungs were determined easily; for estimation of 132 I and 133 I activities in thyroid, sophisticated methods of spectra processing were developed. According to thyroid measurement data, the mean ratio of 133 I/ 131 I activities (at the time of the accident) inhaled by residents of Pripyat was 2.0. The mean ratio of thyroid dose from 133 I inhalation to that caused by 131 I amounts to 0.3, which confirms accuracy of dose estimates based on the evolution of the Chernobyl accident. The mean ratio of 132 I activity in thyroid to that of 132 Te in lungs was assessed from the human measurement data to be 0.2, which is in reasonable agreement with the metabolic properties of these radionuclides. The mean ratio of thyroid dose from 132 I originating from 132 Te deposited in lungs to the dose caused by 131 I was 0.13 ± 0.02 for Pripyat residents who did not take KI pills and 0.9 ± 0.1 for persons who took KI pills. Thus, the contribution of short-lived radioiodines to total thyroid dose of Pripyat residents, which was on average 30% for persons who did not apply stable iodine prophylaxis, and about 50% for persons who took KI pills on 26-27 April, should be accounted for in the assessment of thyroid health effects. (author)

  18. The effects of lower than conventional doses of oral nadolol on relative beta 1/beta 2-adrenoceptor blockade.

    Science.gov (United States)

    Wheeldon, N M; McDevitt, D G; Lipworth, B J

    1994-08-01

    1. The aim of the present study was to evaluate the relative beta 1/beta 2 antagonist selectivity of the beta-adrenoceptor blocker nadolol, in lower than conventional clinical doses. 2. Eight normal volunteers received single oral doses of either placebo (PL), nadolol 5 mg (N5), 20 mg (N20) or 80 mg (N80) in a single-blind, randomised crossover design. beta 1-adrenoceptor antagonism was assessed by attenuation of exercise tachycardia, and beta 2-adrenoceptor blockade by effects on salbutamol-induced chronotropic, hypokalaemic and finger tremor responses. The relative percentage attenuation of beta 2 and beta 1-mediated responses was calculated and expressed as beta 2:beta 1 selectivity ratios. 3. Nadolol produced dose-related reductions in exercise tachycardia in keeping with increasing beta 1-adrenoceptor blockade; mean % reduction (95% CI) compared with placebo: N5 10.7 (6.6 to 14.8), N20 21.4 (17.3 to 25.4), N80 38.9 (34.8 to 42.9). However, even the lowest dose of nadolol (5 mg) produced almost complete blunting of beta 2-mediated effects and significantly increase exercise hyperkalaemia; peak exercise hyperkalaemia (mmol l-1) (means and 95% CI): PL 4.88 (4.68 to 5.07), N5 5.36 (5.17 to 5.55), N20 5.48 (5.28 to 5.67), N80 5.42 (5.22 to 5.61). beta 2:beta 1 selectivity ratios significantly increased as the dose of nadolol was reduced. 4. These data suggest that whereas in the clinical dose range nadolol behaves as a non-selective beta-adrenoceptor antagonist, as the dose is reduced this drug demonstrates an increasing degree of selectivity for the beta 2-adrenoceptor.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Analysis and planning of dose-finding studies with active control

    International Nuclear Information System (INIS)

    Helms, Hans-Joachim

    2014-01-01

    In the clinical development of radiopharmaceuticals the dose finding plays an important role. The contribution is focused on the evaluation and planning of dose finding studies with active control. It is of primary interest to find the lowest dose that yields the same efficacy as the active control. Besides the target dose confidence intervals are of importance to describe the quality of the target dose estimation. The calculation of case numbers and the determination of the dose steps to be studied are challenging under practical conditions. The contribution covers the demonstration of the statistical model the parameter estimation and the asymptotic properties based on maximum likelihood theory, the spline-based evaluation of nonlinear dose finding studies with active control and the planning of design and number of cases.

  20. Supermarket purchase contributes to nutrition-related non-communicable diseases in urban Kenya.

    Science.gov (United States)

    Demmler, Kathrin M; Klasen, Stephan; Nzuma, Jonathan M; Qaim, Matin

    2017-01-01

    While undernutrition and related infectious diseases are still pervasive in many developing countries, the prevalence of non-communicable diseases (NCD), typically associated with high body mass index (BMI), is rapidly rising. The fast spread of supermarkets and related shifts in diets were identified as possible factors contributing to overweight and obesity in developing countries. Potential effects of supermarkets on people's health have not been analyzed up till now. This study investigates the effects of purchasing food in supermarkets on people's BMI, as well as on health indicators such as fasting blood glucose (FBG), blood pressure (BP), and the metabolic syndrome. This study uses cross-section observational data from urban Kenya. Demographic, anthropometric, and bio-medical data were collected from 550 randomly selected adults. Purchasing food in supermarkets is defined as a binary variable that takes a value of one if any food was purchased in supermarkets during the last 30 days. In a robustness check, the share of food purchased in supermarkets is defined as a continuous variable. Instrumental variable regressions are applied to control for confounding factors and establish causality. Purchasing food in supermarkets contributes to higher BMI (+ 1.8 kg/m2) (Pobese (Pobesity, supermarkets contribute to nutrition-related NCDs. Effects of supermarkets on nutrition and health can mainly be ascribed to changes in the composition of people's food choices.

  1. Natural radiation dose estimates from soils

    International Nuclear Information System (INIS)

    Silveira, M.A.G.R.; Moreira, H.; Medina, N.H.

    2009-01-01

    In this work the natural radiation from soils of southeastern Brazil has been studied. Soil samples from Interlagos, Sao Paulo; parks and Billings dam, in Sao Bernardo do Campo city; Santos, Sao Vicente and Sao Sebastiao beaches, Sao Paulo and sands from Ilha Grande beaches, Rio de Janeiro, were analyzed. The results show that the main contribution to the effective dose is due to elements of the 232 Th decay chain, with a smaller contribution from the radionuclide 40 K and the elements of the series of 238 U. The obtained values found in the studied regions, are around the average international dose due to external exposure to gamma rays (0.48 mSv/yr), except in Praia Preta, Ilha Grande, where the effective dose exceeds the average value. (author)

  2. Bicycling-related accidents and factors contributing to injury

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Perez, L.M.; Wideberg, J.; Gonzalez Perez-Somarriba, B.

    2016-07-01

    Objective: This study was conducted to find the epidemiological characteristics of bicycling-related maxillofacial fractures in a defined population, and identify factors contributing to injury. Methodology: A prospective study was carried out involving patients presenting with maxillofacial fractures sustained in bicycling-related accidents. Results: Between 908 of all cycling accidents attending for medical treatment, 122 patients (13% of all cycling accidents) were admitted with facial fractures between 2007 and 2014. Male and female ratio was 2.6:1, and the mean age was 29.4 years (standard deviation: 12.8, range: 12-79 years). Causes of injury included collisions (63%) and accidental falls (37%). The fracture patterns seen were mandibular (49%), zygomatic (32%), orbital (13%), nasal (7%), maxillary (2%), and frontal (2%). Condylar fractures were the most common of the mandibular fractures (63%). The most frequently observed concomitant lesions were orthopedic injuries. Conclusions: Bicycling-related maxillofacial injuries are common and therefore important to identify in order to design a sustainable transport system and for units that provide assistance to traffic accident victims. Missed diagnosis or delayed treatment can lead to facial deformities and functional problems. Wearing protective helmets and the improvement of the helmets design is one aspect that would be of interest for the prevention of injuries. Keywords: Cycling; bicycle-related trauma; maxillofacial fractures; risk factors; helmets. (Author)

  3. Study of dose effect relationship at low doses for non quantitative reactions of skin intestinal mucosa and lung

    International Nuclear Information System (INIS)

    Dutreix, J.; Wambersie, A.

    1977-01-01

    Most of the biological reactions observed in animal experiments or in clinical studies are non quantitative and they only allow assessing an inequality between the effects produced by different irradiations. The method used in non quantitative studies is actually based on the relative contribution of irreparable events and reparable to the cell killing. It provides for the cell population involved in non quantitative biological effects some data which can be expressed in term of a cell survival curve. Such data can be useful in Radiation therapy particularly for maximizing the difference between biological effects by a proper choice of the fraction size. The initial part of the cell survival curve, within the range of doses actually used appears to be a straight exponential. This should allow the extrapolation to very low doses in the range of interest to Radiation Protection

  4. Low-dose strontium stimulates osteogenesis but high-dose doses cause apoptosis in human adipose-derived stem cells via regulation of the ERK1/2 signaling pathway.

    Science.gov (United States)

    Aimaiti, Abudousaimi; Maimaitiyiming, Asihaerjiang; Boyong, Xu; Aji, Kaisaier; Li, Cao; Cui, Lei

    2017-12-19

    Strontium is a widely used anti-osteoporotic agent due to its dual effects on inhibiting bone resorption and stimulating bone formation. Thus, we studied the dose response of strontium on osteo-inductive efficiency in human adipose-derived stem cells (hASCs). Qualitative alkaline phosphatase (ALP) staining, quantitative ALP activity, Alizarin Red staining, real-time polymerase chain reaction and Western blot were used to investigate the in vitro effects of a range of strontium concentrations on hASC osteogenesis and associated signaling pathways. In vitro work revealed that strontium (25-500 μM) promoted osteogenic differentiation of hASCs according to ALP activity, extracellular calcium deposition, and expression of osteogenic genes such as runt-related transcription factor 2, ALP, collagen-1, and osteocalcin. However, osteogenic differentiation of hASCs was significantly inhibited with higher doses of strontium (1000-3000 μM). These latter doses of strontium promoted apoptosis, and phosphorylation of ERK1/2 signaling was increased and accompanied by the downregulation of Bcl-2 and increased phosphorylation of BAX. The inhibition of ERK1/2 decreased apoptosis in hASCs. Lower concentrations of strontium facilitate osteogenic differentiation of hASCs up to a point; higher doses cause apoptosis of hASCs, with activation of the ERK1/2 signaling pathway contributing to this process.

  5. Proceedings of an international workshop on historic dose experience and dose reduction (ALARA) at nuclear power plants

    International Nuclear Information System (INIS)

    Horan, J.R.; Baum, J.W.; Dionne, B.J.

    1985-06-01

    Dose reduction data and experience from 28 foreign and 10 US nuclear power plants was examined to determine causes for the wide variations in occupational dose from country to country. Major topics discussed were: steam generator and refueling maintenance problems; utility and supplier ALARA programs; effectiveness of dose-reduction modifications; attitudes and training; current and future dose-reduction research. While many parameters contribute to differences of occupational doses between plants from different nations, it is clear that most US plants have higher collective dose equivalent per reactor per megawatt-year than most other countries, even for plants of similar size and age. Worldwide, Finnish and Swedish plants, both PWR and BWR, have achieved the lowest values. Major factors which contribute to low doses include: (1) minimization of cobalt in primary system components exposed to water; (2) careful plant design, layout and component segregation and shielding; (3) plant standardization; (4) selection of components and systems for increased reliability; (5) management interest and commitment; (6) minimum number of workers and in-depth worker training; (7) careful control of primary system oxygen and pH; (8) good primary system water purity to minimize corrosion product formation; (9) use of special tools and robotics; (10) decontamination and passivation of primary systems and components; and (11) extent of backfitting and mandated inspections

  6. Dispersion relation for hadronic light-by-light scattering: two-pion contributions

    Energy Technology Data Exchange (ETDEWEB)

    Colangelo, Gilberto [Albert Einstein Center for Fundamental Physics, Institute for Theoretical Physics, University of Bern, Sidlerstrasse 5, 3012 Bern (Switzerland); Hoferichter, Martin [Institute for Nuclear Theory, University of Washington, Seattle, WA 98195-1550 (United States); Kavli Institute for Theoretical Physics, University of California,Santa Barbara, CA 93106 (United States); Procura, Massimiliano [Theoretical Physics Department, CERN, Geneva (Switzerland); Stoffer, Peter [Helmholtz-Institut für Strahlen- und Kernphysik (Theory)and Bethe Center for Theoretical Physics, University of Bonn, 53115 Bonn (Germany); Department of Physics, University of California at San Diego, La Jolla, CA 92093 (United States)

    2017-04-27

    In this third paper of a series dedicated to a dispersive treatment of the hadronic light-by-light (HLbL) tensor, we derive a partial-wave formulation for two-pion intermediate states in the HLbL contribution to the anomalous magnetic moment of the muon (g−2){sub μ}, including a detailed discussion of the unitarity relation for arbitrary partial waves. We show that obtaining a final expression free from unphysical helicity partial waves is a subtle issue, which we thoroughly clarify. As a by-product, we obtain a set of sum rules that could be used to constrain future calculations of γ{sup ∗}γ{sup ∗}→ππ. We validate the formalism extensively using the pion-box contribution, defined by two-pion intermediate states with a pion-pole left-hand cut, and demonstrate how the full known result is reproduced when resumming the partial waves. Using dispersive fits to high-statistics data for the pion vector form factor, we provide an evaluation of the full pion box, a{sub μ}{sup π-box}=−15.9(2)×10{sup −11}. As an application of the partial-wave formalism, we present a first calculation of ππ-rescattering effects in HLbL scattering, with γ{sup ∗}γ{sup ∗}→ππ helicity partial waves constructed dispersively using ππ phase shifts derived from the inverse-amplitude method. In this way, the isospin-0 part of our calculation can be interpreted as the contribution of the f{sub 0}(500) to HLbL scattering in (g−2){sub μ}. We argue that the contribution due to charged-pion rescattering implements corrections related to the corresponding pion polarizability and show that these are moderate. Our final result for the sum of pion-box contribution and its S-wave rescattering corrections reads a{sub μ}{sup π-box}+a{sub μ,J=0}{sup ππ,π-pole} {sup LHC}=−24(1)×10{sup −11}.

  7. Results of comparative assessment of US and foreign nuclear power plant dose experience and dose reduction programs

    International Nuclear Information System (INIS)

    Baum, J.W.; Horan, J.R.; Dionne, B.J.

    1985-01-01

    The objectives of this study were to determine how collective dose equivalents at US nuclear power plants compare to those of other technically advanced countries, and to evaluate factors that contribute to the differences. Fifty Health Physicists and nuclear engineers from 10 countries met at BNL May 29 - June 1, 1984 to exchange information and hold discussions on ''Historical Dose Experience and Dose Reduction (ALARA) at Nuclear Power Plants''. Results of evaluation of data from this meeting and other data from recent publications are summarized. Based on data evaluated to date it is clear that US plants have higher collective dose equivalents per reactor and per MW-yr generated than most other countries. Factors which contribute to low doses include: 1) minimization of cobalt in primary system components exposed to water, 2) careful control of primary system oxygen and pH, 3) good primary system water purity to minimize corrosion product formation, 4) careful plant design, layout and component segregation and shielding, 5) management interest and commitment, 6) minimum number of workers and in-depth worker training, 7) use of special tools, and 8) plant standardization

  8. The current contribution of diagnostic radiology to the population dose in Great Britain

    International Nuclear Information System (INIS)

    Wall, B.F.; Rae, S.; Kendall, G.M.; Darby, S.C.; Fischer, E.S.; Harries, S.V.

    1980-01-01

    The National Radiological Protection Board of the UK has just completed a national survey to determine the genetically significant dose (GSD) to the population of Great Britain from diagnostic radiology. A statistically selected sample of about 80 hospitals spread throughout England, Scotland and Wales has supplied information on the numbers of patients examined in their X-ray departments during a week in June 1977, together with details of age, sex and examination technique. This sample is sufficient to make a reliable estimate of the total diagnostic work-load in all National Health Service Hospitals throughout Great Britain for a year. Gonadal doses from 16 examination types that are likely to be the main contributors to the GSD have been measured on nearly 5000 patients at 20 hospitals throug'out the country using specially developed thermoluminescent dosemeters. These gonadal doses are combined with the examination frequency figures and current values for child expectancy derived from data supplied by tthe registrar general, to estimate the GSD. Those changes in practice which have occurred since the late 1950's which may have influenced the new value for the GSD are discussed, as well as the progress that has been made in estimating population somatic doses from diagnostic radiology using clinical measurements that are currently underway. (H.K.)

  9. Relation between treatment efficacy and cumulative dose of alpha interferon in chronic hepatitis B. European Concerted Action on Viral Hepatitis (Eurohep)

    DEFF Research Database (Denmark)

    Krogsgaard, K; Christensen, E; Bindslev, N

    1996-01-01

    Alpha interferon (IFN) is an established treatment of chronic hepatitis B. The effect has been shown to be dose related, recommended dose regimens being associated with a doubling of the spontaneous, baseline HBeAg to anti-HBe seroconversion rate. However, the efficacy of IFN treatment in relation...

  10. Radiation dose estimates for carbon-11-labelled PET tracers

    International Nuclear Information System (INIS)

    Aart, Jasper van der; Hallett, William A.; Rabiner, Eugenii A.; Passchier, Jan; Comley, Robert A.

    2012-01-01

    Introduction: Carbon-11-labelled positron emission tomography (PET) tracers commonly used in biomedical research expose subjects to ionising radiation. Dosimetry is the measurement of radiation dose, but also commonly refers to the estimation of health risk associated with ionising radiation. This review describes radiation dosimetry of carbon-11-labelled molecules in the context of current PET research and the most widely used regulatory guidelines. Methods: A MEDLINE literature search returned 42 articles; 32 of these were based on human PET data dealing with radiation dosimetry of carbon-11 molecules. Radiation burden expressed as effective dose and maximum absorbed organ dose was compared between tracers. Results: All but one of the carbon-11-labelled PET tracers have an effective dose under 9 μSv/MBq, with a mean of 5.9 μSv/MBq. Data show that serial PET scans in a single subject are feasible for the majority of radiotracers. Conclusion: Although differing in approach, the two most widely used regulatory frameworks (those in the USA and the EU) do not differ substantially with regard to the maximum allowable injected activity per PET study. The predictive validity of animal dosimetry models is critically discussed in relation to human dosimetry. Finally, empirical PET data are related to human dose estimates based on homogenous distribution, generic models and maximum cumulated activities. Despite the contribution of these models to general risk estimation, human dosimetry studies are recommended where continued use of a new PET tracer is foreseen.

  11. Radiation doses and correlated late effects in diagnostic radiology

    International Nuclear Information System (INIS)

    Gustafsson, M.

    1980-04-01

    Patient irradiation in diagnostic radiology was estimated from measurements of absorbed doses in different organs, assessment of the energy imparted and retrospective calculations based on literature data. Possible late biological effects, with special aspects on children, were surveyed. The dose to the lens of the eye and the possibility of shielding in carotid angiography was studied as was the absorbed dose to the thyroid gland at cardiac catheterization and angiocardiography in children. Calculations of the mean bone marrow dose and gonad doses were performed in children with chronic skeletal disease revealing large contributions from examinations of organs other than the skeleton. The dose distribution in the breast in mammography was investigated. Comparison of the energy imparted in common roentgen examinations in 1960 and 1975 showed an unexpected low decrease in spite of technical improvements. Reasons for the failing decrease are discussed. The energy imparted to children in urological examinations was reduced significantly due to introduction of high sensitivity screens and omission of dose demanding projections. Contributions to the possible late effects were estimated on the basis of the organ doses assessed. (author)

  12. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Woo; Hong, Se Mie [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of)

    2011-11-15

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  13. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    International Nuclear Information System (INIS)

    Lee, Jeong Woo; Hong, Se Mie

    2011-01-01

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  14. A model for radiological dose assessment in an urban environment

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Kim, Eun Han; Jeong, Hyo Joon; Suh, Kyung Suk; Han, Moon Hee

    2007-01-01

    A model for radiological dose assessment in an urban environment, METRO-K has been developed. Characteristics of the model are as follows ; 1) mathematical structures are simple (i.e. simplified input parameters) and easy to understand due to get the results by analytical methods using experimental and empirical data, 2) complex urban environment can easily be made up using only 5 types of basic surfaces, 3) various remediation measures can be applied to different surfaces by evaluating the exposure doses contributing from each contamination surface. Exposure doses contributing from each contamination surface at a particular location of a receptor were evaluated using the data library of kerma values as a function of gamma energy and contamination surface. A kerma data library was prepared for 7 representative types of Korean urban building by extending those data given for 4 representative types of European urban buildings. Initial input data are daily radionuclide concentration in air and precipitation, and fraction of chemical type. Final outputs are absorbed dose rate in air contributing from the basic surfaces as a function of time following a radionuclide deposition, and exposure dose rate contributing from various surfaces constituting the urban environment at a particular location of a receptor. As the result of a contaminative scenario for an apartment built-up area, exposure dose rates show a distinct difference for surrounding environment as well as locations of a receptor

  15. Dose Reduction and Dose Management in Computed Tomography - State of the Art.

    Science.gov (United States)

    Zinsser, Dominik; Marcus, Roy; Othman, Ahmed E; Bamberg, Fabian; Nikolaou, Konstantin; Flohr, Thomas; Notohamiprodjo, Mike

    2018-03-13

     For years, the number of performed CT examinations has been rising. At the same time, computed tomography became more dose efficient. The aim of this article is to give an overview about the state of the art in dose reduction in CT and to highlight currently available tools in dose management.  By performing a literature research on Pubmed regarding dose reduction in CT, relevant articles were identified and analyzed.  Technical innovations with individual adaptation of tube current and voltage as well as iterative image reconstruction enable a considerable dose reduction with preserved image quality. At the same time, dedicated software tools are able to handle huge amounts of data and allow to optimize existing examination protocols.   · CT examinations are increasingly performed and contribute considerably to non-natural radiation exposure.. · A correct indication is crucial for each CT examination.. · The examination protocol has to be tailored to the medical question and patient.. · Multiple technical innovations enable considerable dose reduction with constant image quality.. · Dose management with dedicated software tools gains importance.. · Zinsser D, Marcus R, Othman AE et al. Dose reduction and dose management in computed tomography - State of the art. Fortschr Röntgenstr 2018; DOI: 10.1055/s-0044-101261. © Georg Thieme Verlag KG Stuttgart · New York.

  16. An analysis of ingestion doses from a range of postulated Magnox reactor releases

    International Nuclear Information System (INIS)

    Nair, S.

    1985-06-01

    An analysis has been carried out of ingestion doses from a range of postulated Magnox reactor releases to atmosphere. Calculations were made of the dose to the adult, ten year old child and one year old child, which showed the one year old child to receive the highest dose. Detailed studies were made of the significance of the ingestion dose to the one year old child in relation to other exposure routes. The ingestion dose was also analysed in terms of the contributing critical organs, foods and nuclides. Approximate calculations were also made of the dependence of the ingestion dose on the time of year when the release occurs. The results of the analysis were used to derive a set of release-specific Emergency Action Guidance Levels (EAGLs) of critical nuclide concentrations in the critical foods, which comply with NRPB's ingestion ERL recommendations. The EAGLs were supplemented with a corresponding set of EAGLs for grass, for use in situations where crop samples were not readily available. (author)

  17. Effects of secondary interactions on the dose calculation in treatments with Boron Neutron Capture Therapy (BNCT)

    International Nuclear Information System (INIS)

    Monteiro, E.

    2004-01-01

    The aimed of this work consists of evaluating the influence of the secondary contributions of dose (thermal neutrons dose, epithermal neutrons dose, fast neutrons dose and photon dose) in treatment planning with BNCT. MCNP4B Code was used to calculate RBE-Gy doses through the irradiation of the modified Snyder head head phantom.A reduction of the therapeutical gain of monoenergetic neutron beans was observed in non invasive treatments, provoked for the predominance of the fast neutron dose component in the skin, showing that the secondary contributions of dose can contribute more in the direction to raise the dose in the fabric healthy that in the tumor, thus reducing the treatment efficiency. (author)

  18. Study of dose distribution in dental radiology using the Monte Carlo Simulation; Estudo da distribuicao de dose em radiologia odontologica usando simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Bonzoumet, S P.J.; Braz, D; Lopes, R T [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Anjos, M J [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica; Barroso, R C.S. [Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica

    2003-11-15

    Full text: The purpose of this study was to study the absorbed dose in mouth due to scattering in teeth in dental radiography using the monte carlo simulation. The Electron Gamma Shower (EGS-4) system of computer codes was used, which is a general purpose package for monte carlo simulation of the coupled transport of electrons and photons in an arbitrary geometry for particles with energies above a few keV up to several TeV. In the case of a X ray dental the low energy photons beam, are removed of the spectrum by the filtration. These low energy photons beam do not contribute in the obtaining of the radiographic image, but they will be contribute in the dose to the patient, however when the incident radiation crosses the tooth it generates a scattering radiation that contributes in the dose received by the patient in the oral cavity (cheek, tooth and oral cavity). Dental radiography is one of the largest single groups of radiographic examination accounting for 32% of radiographs taken in the Brazil. A number of relatively recent improvements in technology, equipment and techniques have the potential to reduce patient radiation dose and improve image quality. To optimize radiation protection all reasonable means should be employed to minimize the dose of each exposure. Dentists therefore need to keep up to date with changes in techniques and equipment and modify their own practice. In preliminary analysis could be notice that the energy below the 30 keV (low energy) is deposited in the cheek. To 30 keV photons there is the maximum absorbed energy in the tooth (about 60%). In 40 keV could be notice that deposited energy is same to teeth and cheek, but up to 40 keV just a small part of energy is deposited, e.g., the great part of energy is transmitted to the inner mouth (oral cavity). (orig.)

  19. Ultra-low Dose CT for Attenuation Correction of 82Rb Cardiac PET

    DEFF Research Database (Denmark)

    Sørensen, Maria Balshøj; Bouchelouche, Kirsten; Tolbod, Lars Poulsen

    Aim: Myocardial perfusion imaging (MPI) using cardiac PET with tracers like 82Rb and 15O-water is substantially lower in radiation dose than classic MIBI-based SPECT. However, for cardiac PET, the dose contribution of CT for attenuation correction (CTAC) is typically 20-30% of the total dose....... To reduce the total radiation dose of cardiac PET further, we set out to examine if the use of ultra-low dose CTAC (UL-CTAC) would affect the accuracy of the quantitative parameters related to MPI. Furthermore, we examined whether the low quality of the UL-CTAC would affect the technologist’s ability...... to perform manual adjustment for misalignment between PET and CTAC. The CT reconstruction algorithm Q.AC was used to improve quality and consistency of the CTAC. Method: 23 consecutive clinical patients (BMI: 26.9 [range: 15.4-38.8]) referred for 82Rb PET rest and stress imaging were included in the study...

  20. Dose-Time Relations for Induction of Lung Cancer in Uranium Miners

    Energy Technology Data Exchange (ETDEWEB)

    Blair, H. A. [University of Rochester School of Medicine and Dentistry, Rochester, NY (United States)

    1969-11-15

    Lack of data on the concentration of radon and daughters in the air inhaled by uranium miners has made it difficult in the past to establish radiation dose and time factors for induction of lung cancer. Recent determinations by others of {sup 210}Pb in the bones of miners who died of cancer provide, however, a new approach. Because {sup 210}Pb, a decay product of radon, accumulates in bone but is also excreted, its concentration, after prolonged exposure, will approach an equilibrium which is a measure of the rate of exposure. It is shown that the {sup 210}Pb. levels in bone at the end of mining are as closely proportional to existing measured and estimated exposure rates to radon as can be expected. It is reasonable, therefore, to use {sup 210}Pb levels in bone as measures of prior exposure rates. When this is done a graph of survival times from beginning of exposures against reciprocal of {sup 210}Pb shows that lung cancer in man exhibits the two types, early and late, previously revealed in bone cancer in dogs and skin cancer in rats. When the dose is high, death follows initiation of cancer in about 7 years. When the dose is low, the usual case, there is an additional latency of 16 years so the time from attainment of initiating dose to death is 23 years. The initiating dose for the high dose type is about 65 pCi {sup 210}Pb per gram years and for the low dose type about 10 pCi per gram years which, in terms of exposure, is about 400 working level months, WLM, as working level, WL, is currently defined. Of the derived parameters the total low dose development time of 23 years is fairly accurate. The high dose development time of 7 years is less certain. The initiating low dose of 10 pCi per gram years is probably moderately accurate, but its counterpart of 400 WLM less certain. The high initiating dose is poorly determined. Twenty three lung cancer cases were involved in this study. Additional cases along with additional environmental and other measurements

  1. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    International Nuclear Information System (INIS)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young

    2016-01-01

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety

  2. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young [Dept. of Nuclear Engineering, Kyung Hee University, Yongin (Korea, Republic of)

    2016-11-15

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety.

  3. Relative effect of dose-rate values and fractionation on late responding tissues and tumours

    International Nuclear Information System (INIS)

    Malgieri, F.

    1995-01-01

    There are currently available different facilities for radiotherapy also with regard to the dose-rate values (in the ranges LDR - MDR - HDR), sometimes used alternatively or subsequently for the same tumour. We have set up a 'unitary' L-Q model, based on Liversage's and Dale's works, that explicitly include also the dose-rate value and a correction factor of the β parameter depending on the sublethal damage repair time constant, on the length of time of each irradiation and on the time interval between following irradiation for to realize the effect of the incomplete repair when the time interval is short as, for example, in the PLDR. This 'unitary' L-Q model is, of course, usable in the same way both for external beam therapy and for curietherapy and make possible to compute and compare, for each kind of tumour and normal tissue, the relative effect of the different available modality of radiotherapy also with regard to the dose-rate. We show and discuss the resulting relationships of the ratio BED 'late'/BED tumour changing the time-dose parameters and the values of the biological characteristic parameters T p , α/β and μ, for defined size of tumour control and different value of the doserate

  4. Long-term effects of ionizing radiation after the Chernobyl accident: Possible contribution of historic dose.

    Science.gov (United States)

    Omar-Nazir, Laila; Shi, Xiaopei; Moller, Anders; Mousseau, Timothy; Byun, Soohyun; Hancock, Samuel; Seymour, Colin; Mothersill, Carmel

    2018-08-01

    The impact of the Chernobyl NPP accident on the environment is documented to be greater than expected, with higher mutation rates than expected at the current, chronic low dose rate. In this paper we suggest that the historic acute exposure and resulting non-targeted effects (NTE) such as delayed mutations and genomic instability could account at least in part for currently measured mutation rates and provide an initial test of this concept. Data from Møller and Mousseau on the phenotypic mutation rates of Chernobyl birds 9-11 generations post the Chernobyl accident were used and the reconstructed dose response for mutations was compared with delayed reproductive death dose responses (as a measure of genomic instability) in cell cultures exposed to a similar range of doses. The dose to birds present during the Chernobyl NPP accident was reconstructed through the external pathway due to Cs-137 with an estimate of the uncertainty associated with such reconstruction. The percentage of Chernobyl birds several generations after the accident without mutations followed the general shape of the clonogenic survival percentage of the progeny of irradiated cells, and it plateaued at low doses. This is the expected result if NTE of radiation are involved. We suggest therefore, that NTE induced by the historic dose may play a role in generating mutations in progeny many generations following the initial disaster. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Estimating the leakage contribution of phosphate dosed drinking water to environmental phosphorus pollution at the national-scale.

    Science.gov (United States)

    Ascott, M J; Gooddy, D C; Lapworth, D J; Stuart, M E

    2016-12-01

    Understanding sources of phosphorus (P) to the environment is critical for the management of freshwater and marine ecosystems. Phosphate is added at water treatment works for a variety of reasons: to reduce pipe corrosion, to lower dissolved lead and copper concentrations at customer's taps and to reduce the formation of iron and manganese precipitates which can lead to deterioration in the aesthetic quality of water. However, the spatial distribution of leakage into the environment of phosphate added to mains water for plumbosolvency control has not been quantified to date. Using water company leakage rates, leak susceptibility and road network mapping, we quantify the total flux of P from leaking water mains in England and Wales at a 1km grid scale. This is validated against reported leaks for the UKs largest water utility. For 2014, we estimate the total flux of P from leaking mains to the environment to be c. 1.2ktP/year. Spatially, P flux is concentrated in urban areas where pipe density is highest, with major cities acting as a significant source of P (e.g. London into the Thames, with potentially 30% of total flux). The model suggests the majority (69%) of the P flux is likely to be to surface water. This is due to leakage susceptibility being a function of soil corrosivity and shrink-swell behaviour which are both controlled by presence of low-permeability clays. The location of major cities such as London close to the coast results in a potentially significant flux of P from mains leakage to estuarine environments. The contribution of leakage of phosphate dosed mains water should be considered in future source apportionment and ecosystem management. The methodology presented is generic and can be applied in other countries where phosphate dosing is undertaken or used prior to dosing during investment planning. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  6. Dose and perceived image quality in chest radiography

    International Nuclear Information System (INIS)

    Veldkamp, Wouter J.H.; Kroft, Lucia J.M.; Geleijns, Jacob

    2009-01-01

    Chest radiography is the most commonly performed diagnostic X-ray examination. The radiation dose to the patient for this examination is relatively low but because of its frequent use, the contribution to the collective dose is considerable. Consequently, optimization of dose and image quality offers a challenging area of research. In this article studies on dose reduction, different detector technologies, optimization of image acquisition and new technical developments in image acquisition and post processing will be reviewed. Studies indicate that dose reduction in PA chest images to at least 50% of commonly applied dose levels does not affect diagnosis in the lung fields; however, dose reduction in the mediastinum, upper abdomen and retrocardiac areas appears to directly deteriorate diagnosis. In addition to patient dose, also the design of the various digital detectors seems to have an effect on image quality. With respect to image acquisition, studies showed that using a lower tube voltage improves visibility of anatomical structures and lesions in digital chest radiographs but also increases the disturbing appearance of ribs. New techniques that are currently being evaluated are dual energy, tomosynthesis, temporal subtraction and rib suppression. These technologies may improve diagnostic chest X-ray further. They may for example reduce the negative influence of over projection of ribs, referred to as anatomic noise. In chest X-ray this type of noise may be the dominating factor in the detection of nodules. In conclusion, optimization and new developments will enlarge the value of chest X-ray as a mainstay in the diagnosis of chest diseases.

  7. Evaluation of variation of voltage (kV) absorbed dose in chest CT scans

    International Nuclear Information System (INIS)

    Mendonca, Bruna G.A.; Mourao, Arnaldo P.

    2013-01-01

    Computed tomography (CT) is one of the most important diagnostic techniques images today. The increasing utilization of CT implies a significant increase of population exposure to ionizing radiation. Optimization of practice aims to reduce doses to patients because the image quality is directly related to the diagnosis. You can decrease the amount of dose to the patient, and maintain the quality of the image. There are several parameters that can be manipulated in a CT scan and these parameters can be used to reduce the energy deposited in the patient. Based on this, we analyzed the variation of dose deposited in the lungs, breasts and thyroid, by varying the supply voltage of the tube. Scans of the thorax were performed following the protocol of routine chest with constant and variable current for the same applied voltage. Moreover, a female phantom was used and thermoluminescent dosimeters (TLD-100), model bat, were used to record the specific organ doses. Scans were performed on a GE CT scanner, model 64 Discovery channels. Higher doses were recorded for the voltage of 120 kV with 200 mAs in the lungs (22.46 mGy) and thyroid (32.22 mGy). For scans with automatic mAs, variable between 100 and 440, this same tension contributed to the higher doses. The best examination in terms of the dose that was used with automatic 80 kV mAs, whose lungs and thyroid received lower dose. For the best breast exam was 100 kV. Since the increase in the 80 kV to 100 kV no impact so much the dose deposited in the lungs, it can be concluded that lowering the applied voltage to 100 kV resulted in a reduction in the dose absorbed by the patient. These results can contribute to optimizing scans of the chest computed tomography

  8. Radial dose distribution from carbon ion incident on liquid water

    International Nuclear Information System (INIS)

    Scifoni, E.; Surdutovich, E.; Solov'yov, A.V.; Surdutovich, E.

    2010-01-01

    We report calculations of the radial dose deposited along carbon-ion tracks in liquid water using different techniques depending on the energy range of secondary electrons. The models are developed in relation with the experimental data on electron penetration lengths. For electrons with energies higher than 45 eV, we use the Katz model. However, the main focus is on the low-energy electrons, which are largely responsible for DNA damage within 10 nm from the tracks. For these electrons, the dose calculation is based on their random walk behaviour. The results of this combined approach are compared to experimental measurements. Contributions to the deposited energy by electrons of different ranges of energy are discussed. (authors)

  9. Inverse dose-rate-effects on the expressions of extra-cellular matrix-related genes in low-dose-rate γ-ray irradiated murine cells

    International Nuclear Information System (INIS)

    Sugihara, Takashi; Tanaka, Kimio; Oghiso, Yoichi; Murano, Hayato

    2008-01-01

    Based on the results of previous microarray analyses of murine NIH3T3/PG13Luc cells irradiated with continuous low-dose-rate (LDR) γ-ray or end-high-dose-rate-irradiations (end-HDR) at the end of the LDR-irradiation period, the inverse dose-rate-effects on gene expression levels were observed. To compare differences of the effects between LDR-irradiation and HDR-irradiation, HDR-irradiations at 2 different times, one (ini-HDR) at the same time at the start of LDR-irradiation and the other (end-HDR), were performed. The up-regulated genes were classified into two types, in which one was up-regulated in LDR-, ini-HDR-, and end-HDR irradiation such as Cdkn1a and Ccng1, which were reported as p53-dependent genes, and the other was up-regulated in LDR- and ini-HDR irradiations such as pro-collagen TypeIa2/Colla2, TenascinC/Tnc, and Fibulin5/Fbln5, which were reported as extra-cellular matrix-related (ECM) genes. The time dependent gene expression patterns in LDR-irradiation were also classified into two types, in which one was an early response such as in Cdkn1a and Ccng1 and the other was a delayed response such as the ECM genes which have no linearity to total dose. The protein expression pattern of Cdkn1a increased dose dependently in LDR- and end-HDR-irradiations, but those of p53Ser15/18 and MDM2 in LDR-irradiations were different from end-HDR-irradiations. Furthermore, the gene expression levels of the ECM genes in embryonic fibroblasts from p53-deficient mice were not increased by LDR- and end-HDR-irradiation, so the delayed expressions of the ECM genes seem to be regulated by p53. Consequently, the inverse dose-rate-effects on the expression levels of the ECM genes in LDR- and end-HDR-irradiations may be explained from different time responses by p53 status. (author)

  10. The relations between the quantity of milligram hours and doses to points A and B in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Martins, H.L.; Albuquerque, L.F.

    1987-01-01

    This paper shows that the mathematic relation used in doses prescription systems of gynecologic brachytherapy is precarious and it only be used in isolated cases, with the owing restrictions. The material, methods and the results are cited, analysing the dose ratio in function of some variables as: ovoid load, uterine probe curvature, etc. (C.G.C.) [pt

  11. Three-dimensional dose-response models of risk for radiation injury carcinogenesis

    International Nuclear Information System (INIS)

    Raabe, O.G.

    1988-01-01

    The use of computer graphics in conjunction with three-dimensional models of dose-response relationships for chronic exposure to ionizing radiation dramaticly clarifies the separate and interactive roles of competing risks. The three dimensions are average dose rate, exposure time, and risk. As an example, the functionally injurious and carcinogenic responses after systemic uptake of Ra-226 by beagles, mice and people with consequent alpha particle irradiation of the bone are represented by three-dimensional dose-rate/time/response surfaces that demonstrate the contributions with the passage of time of the competing deleterious responses. These relationships are further evaluated by mathematical stripping with three-dimensional illustrations that graphically show the resultant separate contribution of each effect. Radiation bone injury predominates at high dose rates and bone cancer at intermediate dose rates. Low dose rates result in spontaneous deaths from natural aging, yielding a type of practical threshold for bone cancer induction. Risk assessment is benefited by the insights that become apparent with these three-dimensional models. The improved conceptualization afforded by them contributes to planning and evaluating epidemiological analyses and experimental studies

  12. 137Cs and 40K concentrations on imported powder milk and its contribution to the annual effective dose by ingestion for children

    International Nuclear Information System (INIS)

    Vargas, D.; Borrell Munnoz, J. L.; D'Alessandro, K.; Gelen Rudnikas, A.; Diaz Rizo, O.; Martinez Herrera, E.; Gonzales Mesa, A.; Marrero Arias, L.; Hilda Zambrano, M.

    2013-01-01

    Low Background Gamma Spectrometry was used to determine activity concentrations of 137 Cs and 40 K on different powder milk samples imported in Cuba for local consumption. Radionuclide concentration has been evaluated using a high-purity germanium (HPGe) detector (2.04 keV of FWHM and 30% of relative efficiency coupled to a low background system. A relative procedure, using the Certified Reference Materials (CRM) IAEA-152 and 154, was implemented. Samples were dried at 105 o C, macerated and sieved at 125 μm using standardized procedures . Results show that radionuclide activities is strongly dependent on milk type (full and skimmed milk) and on its origin, showing in all samples an activity concentration for 137 Cs is from 1.30 to 2.69 Bq kg -1 only in the 54.7 % of them. Annual effective dose committed by powder milk ingestion for children has been estimated as 9.3x10 -3 mSv y -1 , beneath the permissible dose regulated by the Cuban authorities based on doses reported worldwide for population affected only by global fallout. (Author)

  13. Group contribution modelling for the prediction of safety-related and environmental properties

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Abildskov, Jens; Sin, Gürkan

    warming potential and ozone depletion potential. Process safety studies and environmental assessments rely on accurate property data. Safety data such as flammability limits, heat of combustion or auto ignition temperature play an important role in quantifying the risk of fire and explosions among others......We present a new set of property prediction models based on group contributions to predict major safety-related and environmental properties for organic compounds. The predicted list of properties includes lower and upper flammability limits, heat of combustion, auto ignition temperature, global...... models like group contribution (GC) models can estimate data. However, the estimation needs to be accurate, reliable and as little time-consuming as possible so that the models can be used on the fly. In this study the Marrero and Gani group contribution (MR GC) method has been used to develop the models...

  14. Supermarket purchase contributes to nutrition-related non-communicable diseases in urban Kenya.

    Directory of Open Access Journals (Sweden)

    Kathrin M Demmler

    Full Text Available While undernutrition and related infectious diseases are still pervasive in many developing countries, the prevalence of non-communicable diseases (NCD, typically associated with high body mass index (BMI, is rapidly rising. The fast spread of supermarkets and related shifts in diets were identified as possible factors contributing to overweight and obesity in developing countries. Potential effects of supermarkets on people's health have not been analyzed up till now.This study investigates the effects of purchasing food in supermarkets on people's BMI, as well as on health indicators such as fasting blood glucose (FBG, blood pressure (BP, and the metabolic syndrome.This study uses cross-section observational data from urban Kenya. Demographic, anthropometric, and bio-medical data were collected from 550 randomly selected adults. Purchasing food in supermarkets is defined as a binary variable that takes a value of one if any food was purchased in supermarkets during the last 30 days. In a robustness check, the share of food purchased in supermarkets is defined as a continuous variable. Instrumental variable regressions are applied to control for confounding factors and establish causality.Purchasing food in supermarkets contributes to higher BMI (+ 1.8 kg/m2 (P<0.01 and an increased probability (+ 20 percentage points of being overweight or obese (P<0.01. Purchasing food in supermarkets also contributes to higher levels of FBG (+ 0.3 mmol/L (P<0.01 and a higher likelihood (+ 16 percentage points of suffering from pre-diabetes (P<0.01 and the metabolic syndrome (+ 7 percentage points (P<0.01. Effects on BP could not be observed.Supermarkets and their food sales strategies seem to have direct effects on people's health. In addition to increasing overweight and obesity, supermarkets contribute to nutrition-related NCDs. Effects of supermarkets on nutrition and health can mainly be ascribed to changes in the composition of people's food choices.

  15. Insignificant levels of dose

    International Nuclear Information System (INIS)

    Webb, G.A.M.; McLean, A.S.

    1977-01-01

    The procedures recommended by the International Commission on Radiological Protection (ICRP) for making decisions concerning controllable sources of radiation exposure of the public include 'justification' and 'optimisation'. The tool recommended by the ICRP for reaching these decisions is collective dose or dose commitment supplemented by consideration of doses to individuals. In both these considerations the practical problem arises of whether very small doses to large numbers of people should contribute to the final decision-making process. It may be that at levels of dose which are small increments on natural background, the relationship between dose and effect is linear even though the slope may be close to zero. If so, collective dose is a meaningful concept and the calculation of total detriment for the purpose of justification could legitimately include all doses. In the calculation of collective doses for the purpose of optimisation, which involves decisions on how much money or resource should be allocated to dose reduction, it is necessary to appraise radiation detriment realistically. At low levels of dose to the individual such as those small by comparison with variations in natural background within the UK, the risk to the individual is such that his well-being will not be significantly changed by the presence or absence of the radiation dose. These small doses, which are well below the point at which an individual attaches significance, should not carry a societal significance. Societal acceptance of risk is analysed with a view to assessing a level of possible risk, and hence dose, below which resources should not in general be diverted to secure further reduction. A formulation for collective dose commitment is proposed incorporating a cut-off to exclude insignificant doses. The implications of this formulation in practical situations are discussed

  16. Impact of respiratory motion on variable relative biological effectiveness in 4D-dose distributions of proton therapy.

    Science.gov (United States)

    Ulrich, Silke; Wieser, Hans-Peter; Cao, Wenhua; Mohan, Radhe; Bangert, Mark

    2017-11-01

    Organ motion during radiation therapy with scanned protons leads to deviations between the planned and the delivered physical dose. Using a constant relative biological effectiveness (RBE) of 1.1 linearly maps these deviations into RBE-weighted dose. However, a constant value cannot account for potential nonlinear variations in RBE suggested by variable RBE models. Here, we study the impact of motion on recalculations of RBE-weighted dose distributions using a phenomenological variable RBE model. 4D-dose calculation including variable RBE was implemented in the open source treatment planning toolkit matRad. Four scenarios were compared for one field and two field proton treatments for a liver cancer patient assuming (α∕β) x  = 2 Gy and (α∕β) x  = 10 Gy: (A) the optimized static dose distribution with constant RBE, (B) a static recalculation with variable RBE, (C) a 4D-dose recalculation with constant RBE and (D) a 4D-dose recalculation with variable RBE. For (B) and (D), the variable RBE was calculated by the model proposed by McNamara. For (C), the physical dose was accumulated with direct dose mapping; for (D), dose-weighted radio-sensitivity parameters of the linear quadratic model were accumulated to model synergistic irradiation effects on RBE. Dose recalculation with variable RBE led to an elevated biological dose at the end of the proton field, while 4D-dose recalculation exhibited random deviations everywhere in the radiation field depending on the interplay of beam delivery and organ motion. For a single beam treatment assuming (α∕β) x  = 2 Gy, D 95 % was 1.98 Gy (RBE) (A), 2.15 Gy (RBE) (B), 1.81 Gy (RBE) (C) and 1.98 Gy (RBE) (D). The homogeneity index was 1.04 (A), 1.08 (B), 1.23 (C) and 1.25 (D). For the studied liver case, intrafractional motion did not reduce the modulation of the RBE-weighted dose postulated by variable RBE models for proton treatments.

  17. High-dose (70-78 GY) conformal radiotherapy for prostate cancer; the relation between observed late bladder and rectum complications and parameters derived from the dose volume histograms

    International Nuclear Information System (INIS)

    Lebesque, J.V.; Bruce, A.; Boersma, L.J.; Velde, A. te

    1996-01-01

    Purpose: To determine the incidence of late gastrointestinal (GI) and genitourinary (GU) complications after conformal radiotherapy for prostate cancer, and to investigate the relation between these observed incidences and parameters derived from the Dose Volume Histograms (DVHs) of rectum and bladder wall. Patients and Methods: Hundred and thirty patients with T 2-4 G 1-3 N 0 M 0 prostate cancer were treated with conformal radiotherapy with the simultaneous boost technique in a dose-escalating protocol; 78 patients received a total dose of 70 Gy, 11 patients 74 - 76 Gy and 41 patients 78 Gy, each with a dose of 2 Gy per fraction. DVHs of the rectal wall were used to calculate NTCPs according to the model of Kutcher et al. with the estimated parameter values (n = 0.12, m = 0.15, TD 50 = 80 Gy) according to Burman et al. The median follow-up was 17 months (range 6 - 72 months). The crude and actuarial incidence of late (> 6 months) GI and GU complications were determined using the RTOG/EORTC morbidity scoring system (Grade I to IV). Results: Neither for late GI nor for GU complaints, a grade IV complication was observed. GU complaints occurred in 90 patients (69%): 54 patients (42%) only experienced grade I toxicity, 26 patients (20%) had grade II toxicity, and 10 patients (8%) had grade III complications, of which 8 patients (6%) developed a urethral (7 pts) or ureteric stenosis (1 pt). The actuarial incidence of grade III GU complications was 10% at 2 years. Since bladder wall DVHs are unreliable and most grade III complications were not related to the bladder, the grade II and/or III complications were analyzed in terms of the total prescribed dose only, but no correlation could be demonstrated. GI complications occurred in 71 patients (55%): 59 patients (45%) developed a grade I complication, 11 a grade II complication and only 1 patient required laser treatment twice and blood transfusion because of rectal bleeding (grade III). The actuarial incidence of GI

  18. Scatter and leakage contributions to the out-of-field absorbed dose distribution in water phantom around the medical LINAC radiation beams

    International Nuclear Information System (INIS)

    Bordy, J.M.; Bessiere, I.; Ostrowsky, A.; Poumarede, B.; Sorel, S.; Vermesse, D.

    2013-01-01

    This work is carried out within the framework of EURADOS Working Group 9 (WG9) whose general objective is 'to assess non-target organ doses in radiotherapy and the related risks of second cancers, with the emphasis on dosimetry'. The objective of the present work is to provide reference values (i) to evaluate the current methods of deriving three-dimensional dose distributions in and around the target volume using passive dosimeters, (ii) to derive the leakage dose from the head of the medical linear accelerator (LINAC) and the doses due to scattered radiation from the collimator edges and the body (phantom) itself. Radiation qualities of 6, 12 and 20 MV are used with standard calibration conditions described in IAEA TRS 398 and nonstandard conditions at a reference facility at the Laboratoire National Henri Becquerel (CEA LIST/LNE LNHB). An ionisation chamber is used to measure profile and depth dose in especially design water phantom built to enable investigation of doses up to 60 cm from the beam axis. A first set of experiments is carried out with the beam passing through the tank. From this first experiment, penumbra and out-of-field dose profiles including water and collimator scatter and leakage are found over three orders of magnitude. Two further sets of experiments using the same experimental arrangement with the beam outside the tank, to avoid water scatter, are designed to measure collimator scatter and leakage by closing the jaws of the collimator. It is shown that the ratios between water scatter, collimator scatter and leakage depend on the photon energy. Depending on the energy, typical leakage and collimator scatter represents 10-40% and 30-50% of the total out-of-field doses respectively. Water scatter decreases with energy while leakage increases with energy, and collimator scatter varies only slowly with energy. (authors)

  19. Assessment of peak skin dose in interventional cardiology: A comparison between Gafchromic film and dosimetric software em.dose.

    Science.gov (United States)

    Greffier, J; Van Ngoc Ty, C; Bonniaud, G; Moliner, G; Ledermann, B; Schmutz, L; Cornillet, L; Cayla, G; Beregi, J P; Pereira, F

    2017-06-01

    To compare the use of a dose mapping software to Gafchromic film measurement for a simplified peak skin dose (PSD) estimation in interventional cardiology procedure. The study was conducted on a total of 40 cardiac procedures (20 complex coronary angioplasty of chronic total occlusion (CTO) and 20 coronary angiography and coronary angioplasty (CA-PTCA)) conducted between January 2014 to December 2015. PSD measurement (PSD Film ) was obtained by placing XR-RV3 Gafchromic under the patient's back for each procedure. PSD (PSD em.dose ) was computed with the software em.dose©. The calculation was performed on the dose metrics collected from the private dose report of each procedure. Two calculation methods (method A: fluoroscopic kerma equally spread on cine acquisition and B: fluoroscopic kerma is added to one air Kerma cine acquisition that contributes to the PSD) were used to calculate the fluoroscopic dose contribution as fluoroscopic data were not recorded in our interventional room. Statistical analyses were carried out to compare PSD Film and PSD em.dose . The PSD Film median (1st quartile; 3rd quartile) was 0.251(0.190;0.336)Gy for CA-PTCA and 1.453(0.767;2.011)Gy for CTO. For method-A, the PSD em.dose was 0.248(0.182;0.369)Gy for CA-PTCA and 1.601(0.892;2.178)Gy for CTO, and 0.267(0.223;0.446)Gy and 1.75 (0.912;2.584)Gy for method-B, respectively. For the two methods, the correlation between PSD Film and PSD em.dose was strong. For all cardiology procedures investigated, the mean deviation between PSD Film and PSD em.dose was 3.4±21.1% for method-A and 17.3%±23.9% for method-B. The dose mapping software is convenient to calculate peak skin dose in interventional cardiology. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Real-world dose-relativity, tablet burden, and cost comparison of conversion between sevelamer hydrochloride/carbonate and lanthanum carbonate monotherapies.

    Science.gov (United States)

    Keith, Michael S; Sibbel, Scott; Copley, J Brian; Wilson, Rosamund J; Brunelli, Steven M

    2014-10-01

    Sevelamer hydrochloride/carbonate (SH/C) and lanthanum carbonate (LC) are noncalcium-based phosphate binders used for the management of hyperphosphatemia in patients with end-stage renal disease (ESRD). The objectives of this study were to examine the dose-relativity, tablet burden, and cost difference of bidirectional conversion between SH/C and LC monotherapy in a large cohort of real-world patients with ESRD. This retrospective cohort study included three 30-day preconversion periods (days -90 to -61, -60 to -31, and -30 to -1) followed by three 30-day postconversion periods (days 1 to 30, 31 to 60, and 61 to 90); day 0 was the index date of conversion. The full analysis population (FAP) comprised two cohorts: SH/C to LC (S-L) converters and LC to SH/C (L-S) converters. The SH/C:LC dose-relativity ratio was assessed in the dose-relativity subset, defined as patients whose serum phosphate levels fell within a caliper range of ± 0.5 mg/dL in the final preconversion (days -30 to -1) and postconversion (days 61 to 90) periods. Tablet burden and phosphate binder costs were assessed in the FAP. Phosphate binder costs were based on average wholesale prices. The FAP contained a total of 303 patients, comprising the S-L (128 patients) and L-S (175 patients) converter cohorts. The dose-relativity subset contained 159 patients, 72 from the S-L cohort and 87 from the L-S cohort. The overall mean SH/C:LC dose-relativity ratio was 2.27 (95% CI, 2.04 to 2.52). In SH/C dose strata >800 to 2400, >2400 to 4800, >4800 to 7200, and >7200 mg/d, overall mean dose-relativity ratios were 0.79 (95% CI, 0.57 to 1.10), 1.45 (95% CI, 1.20 to 1.75), 2.05 (95% CI, 1.75 to 2.39), and 3.24 (95% CI, 2.89 to 3.66), respectively. The overall mean tablet burden was 6.6 tablets per day lower with LC monotherapy than with SH/C monotherapy (95% CI, -7.1 to -6.0; P 7800 mg/d was the inflection point at which conversion to LC resulted in mean cost savings. Patients requiring SH/C >7800 mg/d comprised

  1. Estimating the relative contributions of maternal genetic, paternal genetic and intrauterine factors to offspring birth weight and head circumference.

    Science.gov (United States)

    Rice, Frances; Thapar, Anita

    2010-07-01

    Genetic factors and the prenatal environment contribute to birth weight. However, very few types of study design can disentangle their relative contribution. To examine maternal genetic and intrauterine contributions to offspring birth weight and head circumference. To compare the contribution of maternal and paternal genetic effects. Mothers and fathers were either genetically related or unrelated to their offspring who had been conceived by in vitro fertilization. 423 singleton full term offspring, of whom 262 were conceived via homologous IVF (both parents related), 66 via sperm donation (mother only related) and 95 via egg donation (father only related). Maternal weight at antenatal booking, current weight and maternal height. Paternal current weight and height were all predictors. Infant birth weight and head circumference were outcomes. Genetic relatedness was the main contributing factor between measures of parental weight and offspring birth weight as correlations were only significant when the parent was related to the child. However, there was a contribution of the intrauterine environment to the association between maternal height and both infant birth weight and infant head circumference as these were significant even when mothers were unrelated to their child. Both maternal and paternal genes made contributions to infant birth weight. Maternal height appeared to index a contribution of the intrauterine environment to infant growth and gestational age. Results suggested a possible biological interaction between the intrauterine environment and maternal inherited characteristics which suppresses the influence of paternal genes. 2010 Elsevier Ltd. All rights reserved.

  2. Tritium metabolism in newborn mice and estimation of the accumulated dose

    Energy Technology Data Exchange (ETDEWEB)

    Saito, M; Ishida, M R

    1986-01-01

    Suckling mice received tritium from their mothers who were supplied with tritiated water as drinking water. After weaning, the offspring were sacrificed and the tritium concentration was determined for various organs and various molecular components including acid soluble component, lipid, RNA, DNA and protein. The accumulated dose for the period between 3 and 41 weeks after birth was calculated for various organs and the contributions of the acid insoluble components to the total dose estimated. The per cent contribution of the acid insoluble components to the total dose was organ specific and was between about 17% and 42%. The result indicates that the inhomogeneous distribution of tritium in subcellular structures needs to be taken into account. The contribution of organically bound tritium to dose is then comparable to that of tritium in the free water component.

  3. The assessment of effects of low doses of ionizing radiations: contributions of epidemiology

    International Nuclear Information System (INIS)

    Verger, P.; Hubert, Ph.; Bard, D.

    1998-01-01

    After a brief recall of the history of the application of epidemiological studies to the field of ionizing radiations (actually to study the consequences of Hiroshima and Nagasaki bombing), and after having outlined that most of these epidemiological studies addressed carcinogenic effects of radiations on populations exposed to doses greater than 0,2 Gy, this article more particularly addresses epidemiological studies for low doses (lower than 0,5-1 Gy). The authors present objectives and methods (monitoring, etiological research, risk quantification), and discuss the limitations of epidemiology and its strengths. In the next part, they comment and discuss the main data sources used for the epidemiological assessment of low doses. These sources respectively deal with Hiroshima and Nagasaki (the Life Span Study, its results in terms of solid cancers and leukaemia, its limitations), with occupational exposures (radiologists, workers in nuclear installations, crews of intercontinental flights, Chernobyl liquidators, uranium minors exposed to radon), with environmental exposures (domestic exposures to radon, exposure to natural radiation, to nuclear test fallouts, and to Chernobyl accident fallouts, exposure about nuclear installations), and with other types of exposure

  4. A graphical review of radiogenic animal cancer data using the 'dose and dose-rate map'

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Hoshi, Yuko; Sakai, Kazuo

    2008-01-01

    We have been investigating the effects of low dose or low dose rate irradiation on mice, using our low dose-rate irradiation facilities. In these studies, we found that the effects were highly dependent on both total dose and dose rate. To show this visually, we proposed the 'dose/dose rate map', and plotted the results of our laboratory and our co-workers. The map demonstrated that dose/dose rate plane could be divided into three areas; 1) An area where harmful effects are observed, 2) An area where no harmful effects are observed, and 3) Another area, between previous two areas, where certain protective functions are enhanced. As this map would be a powerful tool to find some trend among the vast numbers of data relating the biological effects of ionizing radiation, we have developed a computer program which plots the collected data on the dose/dose rate map sorting by experimental conditions. In this study, we graphically reviewed and analyzed the data relating to the lifespan studies of animals with a view to determining the relationships between doses and dose rates of ionizing radiation and cancer incidence. The data contains about 800 sets of experiments, which concerns 187,000 animals exposed to gamma ray or X-ray and their 112,000 controls, and total of about 30,000 cancers in exposed animals and 14,000 cancers in controls. About 800 points of data were plotted on the dose/dose rate map. The plot showed that 1) The divided three areas in the dose/dose rate map were generally confirmed by these 800 points of data, and 2) In some particular conditions, e.g. sarcoma by X-rays, the biologically effective area is extended to relatively high dose/dose rate area. (author)

  5. Examining the Relative Contributions of Content Knowledge and Strategic Processing to Comprehension

    Science.gov (United States)

    Aukerman, Maren; Brown, Rachel; Mokhtari, Kouider; Valencia, Sheila; Palincsar, Annemarie

    2015-01-01

    The essays below were prepared following the LRA session organized by Janice Almasi entitled, "Examining the relative contributions of content knowledge and strategic processing to comprehension." What unites these essays are the personal and historical stances that each writer has taken; in addition, the essays are rich with…

  6. Low dose rate radiation favors apoptosis as a mechanism of cell death

    International Nuclear Information System (INIS)

    Murtha, Albert D.; Rupnow, Brent; Knox, Susan J.

    1997-01-01

    Purpose/Objective: Radioimmunotherapy (RIT) has demonstrated promising results in the treatment of chemotherapy refractory non-Hodgkin's lymphoma. The radiation associated with this therapy is emitted in a continuous fashion at low dose rates (LDR). Results from studies comparing the relative efficacy of LDR radiation and high dose rate (HDR) radiation on malignant cell killing have been variable. This variability may be due in part to the relative contribution of different mechanisms of cell killing (apoptosis or necrosis) at different dose rates. Materials and Methods: In order to test this hypothesis, the relative efficacy of LDR (16.7 cGy/hr) and HDR radiation (422 cGy/min) were compared using a human B cell lymphoma cell line (PW) and a PW clone (c26) stably transfected to overexpress the anti-apoptotic gene Bcl-2. The endpoints evaluated included the relative amount of cell killing, the fraction of cell killing attributable to apoptosis versus necrosis, and the impact of Bcl-2 overexpression on both overall cell killing and the fraction of killing attributable to apoptosis. Results: HDR and LDR radiation resulted in similar overall cell killing in the PW wild type cell line. In contrast, killing of clone c26 cells was dose rate dependent. One third less killing was seen following LDR irradiation of c26 cells compared with equivalent doses of HDR radiation. Analysis of the relative mechanisms of killing following LDR irradiation revealed a relative increase in the proportion of killing attributable to apoptosis. Conclusion: These findings support the hypothesis that in PW cells, LDR radiation appears to be highly dependent on apoptosis as a mechanism of cell death. These findings may have implications for the selection of patients for RIT, and for the treatment of tumors that overexpress Bcl-2. They may also help form the basis for future rational design of effective combined modality therapies utilizing RIT

  7. Job related mortality risks of Hanford workers and their relation to cancer effects of measured doses of external radiation

    International Nuclear Information System (INIS)

    Kneale, G.W.; Mancuso, T.F.; Stewart, A.M.

    1984-01-01

    A continuation of the series by Mancuso, Stewart, and Kneale (MSK) on studies of cancer risks for radiation workers at Hanford is presented. It concentrates on the statistical problems posed by the need to estimate and control for job related mortality risks when there are several changes of occupation and no certainty about how different occupations are related to two socioeconomic factors which have strong health associations-namely, education and income. The final conclusion is that for tissues which are sensitive to cancer induced by radiation there is a risk of cancer for Hanford exposures whose dose response is curvilinear with long latency and increasing effect with increasing exposure age. (author)

  8. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  9. Ingestion of Nevada Test Site Fallout: Internal dose estimates

    International Nuclear Information System (INIS)

    Whicker, F.W.; Kirchner, T.B.; Anspaugh, L.R.

    1996-01-01

    This paper summarizes individual and collective dose estimates for the internal organs of hypothetical yet representative residents of selected communities that received measurable fallout from nuclear detonations at the Nevada Test Site. The doses, which resulted from ingestion of local and regional food products contaminated with over 20 radionuclides, were estimated with use of the PATHWAY food-chain-transport model to provide estimates of central tendency and uncertainty. The thyroid gland received much higher doses than other internal organs and tissues. In a avery few cases, infants might have received thyroid doses in excess of 1 Gy, depending on location, diet, and timing of fallout. 131 I was the primary thyroid dose contributor, and fresh milk was the main exposure pathway. With the exception of the thyroid, organ doses from the ingestion pathway were much smaller (<3%) than those from external gamma exposure to deposited fallout. Doses to residents living closest to the Nevada Test Site were contributed mainly by a few fallout events; doses to more distantly located people were generally smaller, but a greater number of events provided measurable contributions. The effectiveness of different fallout events in producing internal organ doses through ingestion varied dramatically with seasonal timing of the test, with maximum dose per unit fallout occurring for early summer depositions when milk cows were on pasture and fresh, local vegetables were used. Within specific communities, internal doses differed by age, sex, and lifestyle. Collective internal dose estimates for specific geographic areas are provided

  10. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons.

    Science.gov (United States)

    Ballester, Facundo; Granero, Domingo; Pérez-Calatayud, José; Melhus, Christopher S; Rivard, Mark J

    2009-09-01

    The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides (60Co, 137CS, 192Ir, and 169Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source beta-, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the 192Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Electronic equilibrium within 1% is reached for 60Co, 137CS, 192Ir, and 169Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for 60Co and 192Ir, respectively. Electron emissions become important (i.e., > 0.5%) within 3.3 mm of 60Co and 1.7 mm of 192Ir sources, yet are negligible over all distances for 137Cs and 169Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

  11. Risk of therapy-related leukaemia and preleukaemia after Hodgkin's disease. Relation to age, cumulative dose of alkylating agents, and time from chemotherapy

    DEFF Research Database (Denmark)

    Pedersen-Bjergaard, J.; Specht, L.; Larsen, S.O.

    1987-01-01

    391 patients treated intensively for Hodgkin's disease were followed for up to 15 years to evaluate the risk of therapy-related acute non-lymphocytic leukaemia (t-ANLL) and preleukaemia. Only two independent factors, patient age and cumulative dose of alkylating agents, were related to the risk...... of t-ANLL. The hazard rate of t-ANLL was roughly proportional to the square of patient age and to the total cumulative dose of alkylating agents. In 320 patients treated with alkylating agents the cumulative risk of t-ANLL increased steadily from 1 year after the start of treatment and reached 13.......0% (SE 3.0) at 10 years after which time there were no further cases. Calculated from cessation of therapy with alkylating agents, however, the cumulative risk curve increased steeply during the first 1-2 years then gradually levelled out and no new cases were observed beyond 7 years. With a 15-year...

  12. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  13. Dose assessments for SFR 1

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la

    2008-05-01

    were obtained around year 4,000 AD, when an increase of groundwater discharges occurs in connection with the ongoing shoreline displacement. The peaks for the well are also dominated by C-14, although a few other radionuclides also contribute. This pattern of the peak doses was observed for calculation cases of the main scenario and less probable scenarios. Moreover, the predicted doses, including peak dose values, for calculation cases of the less probable scenarios were very close to the predictions for calculation cases of the main scenario. Predicted annual doses to the most exposed individuals during the first 1,000 years after the repository closure did not exceed 0.05 μSv per year. Low release rates are predicted for this period, when the recipient for the releases is the sea, and doses per unit release rate are low, as compared to the case with releases to a lake or a mire. Doses from short-lived radionuclides were very low, as these can only be released during the sea period. The doses from actinides were also low, due to effective retention in the engineered barriers and their low inventory. In general, total mean annual individual doses were low during the whole simulation period, with values below 14 μSv per year for the main and less probable scenarios. Uncertainty analyses were carried out using probabilistic methods. These analyses showed that the parameter uncertainty in the peak doses from releases to the landscape are low due to the dominant role of C-14, for which the dose factors and the biosphere release rates have low uncertainty. Sensitivity studies were carried out to identify the near field and biosphere parameters that have the highest contribution to the uncertainty of the peak dose estimates. The parameters with the highest contribution to the uncertainties in estimates of release rates from the near field are the flow uncertainty factors for non-sorbing radionuclides and the distribution coefficients in the construction cement for sorbing

  14. Dose assessments for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la (Facilia AB, Bromma (Sweden))

    2008-06-15

    were obtained around year 4,000 AD, when an increase of groundwater discharges occurs in connection with the ongoing shoreline displacement. The peaks for the well are also dominated by C-14, although a few other radionuclides also contribute. This pattern of the peak doses was observed for calculation cases of the main scenario and less probable scenarios. Moreover, the predicted doses, including peak dose values, for calculation cases of the less probable scenarios were very close to the predictions for calculation cases of the main scenario. Predicted annual doses to the most exposed individuals during the first 1,000 years after the repository closure did not exceed 0.05 muSv per year. Low release rates are predicted for this period, when the recipient for the releases is the sea, and doses per unit release rate are low, as compared to the case with releases to a lake or a mire. Doses from short-lived radionuclides were very low, as these can only be released during the sea period. The doses from actinides were also low, due to effective retention in the engineered barriers and their low inventory. In general, total mean annual individual doses were low during the whole simulation period, with values below 14 muSv per year for the main and less probable scenarios. Uncertainty analyses were carried out using probabilistic methods. These analyses showed that the parameter uncertainty in the peak doses from releases to the landscape are low due to the dominant role of C-14, for which the dose factors and the biosphere release rates have low uncertainty. Sensitivity studies were carried out to identify the near field and biosphere parameters that have the highest contribution to the uncertainty of the peak dose estimates. The parameters with the highest contribution to the uncertainties in estimates of release rates from the near field are the flow uncertainty factors for non-sorbing radionuclides and the distribution coefficients in the construction cement for sorbing

  15. Study of dose and relative risk of occupationally exposed individuals in interventional procedures; Estudo de dose e risco relativo de individuos ocupacionalmente expostos em procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Silveira Filho, Jose A.M.; Reis, Charlene O.; Taniguti, Lana T.; Pacifico, Leonardo C.; SaintYves, Thalis L.A.; Mecca, Fernando A., E-mail: ze_augustomsf@hotmail.com [Instituto Nacional do Cancer (INCA), Rio de Janeiro, RJ (Brazil). Setor de Fisica Medica

    2012-12-15

    This paper estimates the occupational effective dose and the relative risk of leukemia and cancers of the digestive tract mortality through dose study of the most radiosensitive anatomical regions (lens, thyroid, chest and gonads) of the professionals involved in interventional gonad procedures. It was considered a cumulative exposure time of 10,000 hours, which is the occupational exposure time of an IOE in throughout his professional life. It was also considered that they always use Personal Protective Equipment (PPE). Mathematical models derived from epidemiological data contained in the BEIR V and in the IAEA’s TECDOC 870 are used to estimate the relative risk. The results show a significant increase in mortality risk for these types of cancer for individuals occupationally exposed to three different distances from the x-ray beam, and reinforces that radiation protection measures are essential. (author)

  16. Low doses effects and gamma radiations low dose rates

    International Nuclear Information System (INIS)

    Averbeck, D.

    1999-01-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  17. Management of pediatric radiation dose using Philips fluoroscopy systems DoseWise: perfect image, perfect sense

    International Nuclear Information System (INIS)

    Stueve, Dick

    2006-01-01

    Although image quality (IQ) is the ultimate goal for accurate diagnosis and treatment, minimizing radiation dose is equally important. This is especially true when pediatric patients are examined, because their sensitivity to radiation-induced cancer is two to three times greater than that of adults. DoseWise is an ALARA-based philosophy within Philips Medical Systems that is active at every level of product design. It encompasses a set of techniques, programs and practices that ensures optimal IQ while protecting people in the X-ray environments. DoseWise methods include management of the X-ray beam, less radiation-on time and more dose information for the operator. Smart beam management provides automatic customization of the X-ray beam spectrum, shape, and pulse frequency. The Philips-patented grid-controlled fluoroscopy (GCF) provides grid switching of the X-ray beam in the X-ray tube instead of the traditional generator switching method. In the examination of pediatric patients, DoseWise technology has been scientifically documented to reduce radiation dose to <10% of the dose of traditional continuous fluoroscopy systems. The result is improved IQ at a significantly lower effective dose, which contributes to the safety of patients and staff. (orig.)

  18. Dose contributions due to radiation scattered by air (skyshine) in the case of X-ray machines

    Energy Technology Data Exchange (ETDEWEB)

    Sahre, P.; Kaden, M. [Verein fuer Kernverfahrenstechnik und Analytik Rossendorf e.V. (VKTA), Dresden (Germany). Nuclear Engineering and Analytics Rossendorf; Schoenmuth, T.; Naumann, B. [Hochschule fuer Technik, Wirtschaft und Sozialwesen Zittau/Goerlitz, Zittau (Germany); Pawelke, J. [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany); Technische Univ. Dresden (Germany); OncoRay, Dresden (Germany); Reichelt, U. [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany)

    2012-06-15

    Radiation transport simulations had to be done in preparation of operation of the X-ray tube ISOVOLT 320 kV/13mA in a special laboratory. At first simulation was done without shielding the roof of the laboratory, showing a dose rate maximum of more than 100 mSv/h. This dose rate results in a skyshine dose rate of at most 2 {mu}Sv/h in the surrounding of the building without shielding the roof. For similar geometries the skyshine is negligible for dose rates at the unshielded roof of less than 3 mSv/h (exclusion area). (orig.)

  19. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  20. Contributing and Damaging Factors Related to the Psychological Capital of Teachers: A Qualitative Analysis

    Science.gov (United States)

    Çimen, Ismail; Özgan, Habib

    2018-01-01

    Over the last two decades, psychological capital has gained prominence in the literature on positive organisational behaviour. However, further investigation is still needed in relation to this issue, particularly in the context of educational organisations. Accordingly, this study aimed to examine the contributing and damaging factors relating to…

  1. Preliminary estimates of dose and residual activation of selected components in ring collimation straight of the SNS

    International Nuclear Information System (INIS)

    Ludewig, H.; Catalan-Lasheras, N.; Simos, N.; Walker, J.; Mallen, A.; Wei, J.; Todosow, M.

    2000-01-01

    The highest doses to components in the SNS ring are expected to be to those located in the collimation straight section. In this paper the authors present estimated doses to magnets and cable located between collimators. In addition the buildup of relatively long half-life radioactive isotopes is estimated, following machine operation and shutdown. Finally, the potential dose to operators approaching the machine following operation and shutdown for four hours is made. The results indicate that selected components might require replacement after several years of full power operation. In addition, the reflection of gamma-rays from the tunnel walls contribute a non-negligible amount to the dose of an operator in the tunnel following machine shutdown

  2. Low doses effects and gamma radiations low dose rates; Les effets des faibles doses et des faibles debits de doses de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Averbeck, D [Institut Curie, CNRS UMR 2027, 75 - Paris (France)

    1999-07-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  3. Contribution of N-methyl-D-aspartate receptors to attention and episodic spatial memory during senescence.

    Science.gov (United States)

    Guidi, Michael; Rani, Asha; Karic, Semir; Severance, Barrett; Kumar, Ashok; Foster, Thomas C

    2015-11-01

    A decrease in N-methyl-D-aspartate receptor (NMDAR) function is associated with age-related cognitive impairments. However, NMDAR antagonists are prescribed for cognitive decline associated with age-related neurodegenerative disease, raising questions as to the role of NMDAR activity in cognitive function during aging. The current studies examined effects of NMDAR blockade on cognitive task that are sensitive to aging. Young and middle-age rats were trained on the five-choice serial reaction time task (5-CSRTT) and challenged with MK-801 (0.025, 0.05, and 0.1mg/kg or vehicle). Attention deficits were apparent in middle-age and performance of young and middle-age rats was enhanced for low doses of MK-801 (0.025 and 0.05). The beneficial effects on attention were reversed by the highest dose of MK-801. Older animals exhibited a delay-dependent impairment of episodic spatial memory examined on a delayed-matching to place water maze task. Similarly, a low dose of MK-801 (0.05mg/kg) impaired performance with increasing delay and aged animals were more susceptible to disruption by NMDAR blockade. Despite MK-801 impairment of episodic spatial memory, MK-801 had minimal effects on spatial reference memory. Our results confirm that NMDARs contribute to rapidly acquired and flexible spatial memory and support the idea that a decline in NMDAR function contributes to the age-related impairments in cognition. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Absorbed dose to mice in prolonged irradiation by low-dose rate ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shiragai, Akihiro [National Inst. of Radiological Sciences, Chiba (Japan); Saitou, Mikio; Kudo, Iwao [and others

    2000-07-01

    In this paper, the dose absorbed by mice was evaluated as a preliminary study of the late effects of prolonged continuous irradiation of mice with low-dose rate ionizing radiation. Eight-week-old male and female SPF C3H/HeN mice in three irradiation rooms were exposed to irradiation at 8000, 400, and 20 mGy, respectively, using a {sup 137}Cs {gamma}-source. Nine racks were arranged in a circle approximately 2.5 m from the source in each room, and 10 cages were arranged on the 4 shelves of each rack. Dose distributions, such as in air at the source level, in the three rooms were estimated by using ionization chambers, and the absorbed dose distributions in the room and relative dose distributions in the cages in relation to the distance of the cage center were examined. The mean abdomen doses of the mice measured by TLD were compared with the absorbed doses in the cages. The absorbed dose distributions showed not only inverse-inverse-square-law behavior with distance from the source, but geometric symmetry in every room. The inherent scattering and absorption in each room are responsible for such behavior and asymmetry. Comparison of relative dose distributions revealed cage positions that are not suitable for experiments with high precision doses, but all positions can be used for prolonged continuous irradiation experiments if the position of the cages is rotated regularly. The mean abdomen doses of the mice were similar in each cage. The mean abdomen doses of the mice and the absorbed doses in a cage were almost the same in all cages. Except for errors concerning the positions of the racks and cages, the uncertainties in the exposure doses were estimated to be about {+-}12% for 8000 mGy group, 17% for 400 mGy group, and 35% for 20 mGy group. (K.H.)

  5. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  6. Radioactivity content of Shiraz water supplies and its related effective dose

    International Nuclear Information System (INIS)

    Mehdizadeh, S.; Derakhshan, Sh.

    2004-01-01

    We are exposed naturally to ionizing radiation from cosmic rays and natural radionuclides in the air, ground, food and drinking water. When invested, naturally and radionuclides are distributed among body organs. The average concentrations of naturally occurring radionuclides in drinking water are used to estimated the annual effective dose equivalents. In this work, during October of 2002 to October of 2003, 37 samples from 29 different wells and Doroodzan dam were gathered in winter and summer and the gross Alfa and Beta, total uranium and Ra-226 activity in each sample were determined. The activity of Ra-226 was measured by Radon Emanation method and total uranium was determined using laser Fluorimetry. The mean concentration of Ra-226 was higher in summer but the uranium had higher concentration in winter. The mean concentration of Ra-226 and Uranium were 15.72±1.12 mBq.1 -1 and 9.44±1.14μg.1 -1 in winter ±μ and 29.46 2.18 mBq.1 -1 and 7.37 1.1 g.1 -1 in summer respectively. The average annual effective doses (Ra-226) of different age groups (Adults, children and infants) were equal to 2.37± 0.22, 5.42 ±0.43, 2.66±0.24, mSv.y 1 -1 and 0.136±0.02, 0.18±0.027 and 0.171±0.026 mSv.y -1 due to existence of uranium in drinking water. The results of this survey showed that the radioactive concentration of the radionuclides and their related effective doses are in the normal range and permissible levels. These results are comparable with those found by Atomic Energy Organization of Iran but different with the results of the limited project done during 1999 at Shiraz

  7. Dose from radiological examinations

    International Nuclear Information System (INIS)

    Imamura, Keiko; Uji, Teruyuki; Sakuyama, Keiko; Fujikawa, Mitsuhiro; Fujii, Masamichi

    1976-01-01

    Relatively high gonad doses, several hundred to one thousand mR, have been observed in case of pelvis, hip-joint, coccyx, lower abdomen and lumber examination. Dose to the ovary is especially high in barium enema and I.V.P. examinations. About 12 per cent of the 4-ray examination are high-dose. The gonad dose is relatively high in examination of abdomen and lower extremities, in infants. The dose to the eyes is especially high, 1.0 to 2.5R per exposure, in temporal bone and nasal sinuses tomography. X-ray doses have been compared with dose limits recommended by ICRP and with the gonad dose from natural radiations. The gonad dose in lumbar examination, barium enema, I.V.P. etc. is as high as the maximum permissible dose per year recommended by ICRP. Several devices have been made for dose reduction in the daily examinations: (1) separating the radiation field from the gonad by one centimeter decreases the gonad dose about one-half. (2) using sensitive screens and films. In pelvimetry and in infant hip-joint examination, the most sensitive screen and film are used. In the I.V.P. examination of adult, use of MS screen in place of FS screen decreases the dose to one-third, in combination with careful setting of radiation field, (3) use of grid increases the dose about 50 percent and the lead rubber protection (0.1mm lead equivalent) decreases the gonad dose to one-thirtieth in the spinal column examination of infant, (4) A lead protector, 1mm thickness and 2.5cm in diameter, on the eyes decreases the dose to about one-eighth in the face and nead examinations. These simple and effective methods for dose reduction. Should be carried out in as many examinations as possible in addition to observing dose limits recommended by ICRP. (Evans, J.)

  8. Eye lens dosimetry for interventional procedures – Relation between the absorbed dose to the lens and dose at measurement positions

    International Nuclear Information System (INIS)

    Geber, Therese; Gunnarsson, Mikael; Mattsson, Sören

    2011-01-01

    This study investigated the relationship between the absorbed dose to the lens of the eye and the absorbed dose at different measurement positions near the eye of interventional radiologists. It also visualised the dose distribution inside the head, both when protective eyewear were used and without such protection. The best position for an eye lens dosimeter was found to be at the side of the head nearest to the radiation source, close to the eye. Positioning the dosimeter at the eyebrow could lead to an underestimation of the lens dose of as much as 45%. The measured dose distribution showed that the absorbed dose to the eye lenses was high compared to the other parts of the head, which stresses the importance of wearing protective eyewear. However, many models of eyewear were found to be deficient as the radiation could slip through at several places, e.g. at the cheek. The relationship between the absorbed dose to the lens and the kerma-area-product (P KA ) delivered to the patient was also studied.

  9. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  10. Implications for human and environmental health of low doses of ionising radiation

    International Nuclear Information System (INIS)

    Mothersill, Carmel; Seymour, Colin

    2014-01-01

    The last 20 years have seen a major paradigm shift in radiation biology. Several discoveries challenge the DNA centric view which holds that DNA damage is the critical effect of radiation irrespective of dose. This theory leads to the assumption that dose and effect are simply linked – the more energy deposition, the more DNA damage and the greater the biological effect. This is embodied in radiation protection (RP) regulations as the linear-non-threshold (LNT) model. However the science underlying the LNT model is being challenged particularly in relation to the environment because it is now clear that at low doses of concern in RP, cells, tissues and organisms respond to radiation by inducing responses which are not readily predictable by dose. These include adaptive responses, bystander effects, genomic instability and low dose hypersensitivity, and are commonly described as stress responses, while recognizing that “stress” can be good as well as bad. The phenomena contribute to observed radiation responses and appear to be influenced by genetic, epigenetic and environmental factors, meaning that dose and response are not simply related. The question is whether our discovery of these phenomena means that we need to re-evaluate RP approaches. The so-called “non-targeted” mechanisms mean that low dose radiobiology is very complex and supra linear or sub-linear (even hormetic) responses are possible but their occurrence is unpredictable for any given system level. Issues which may need consideration are synergistic or antagonistic effects of other pollutants. RP, at present, only looks at radiation dose but the new (NTE) radiobiology means that chemical or physical agents, which interfere with tissue responses to low doses of radiation, could critically modulate the predicted risk. Similarly, the “health” of the organism could determine the effect of a given low dose by enabling or disabling a critical response. These issues will be discussed

  11. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  12. Spectra of the linear energy transfer measured with a track etch spectrometer in the beam of 1 GeV protons and the contribution of secondary charged particles to the dose

    International Nuclear Information System (INIS)

    Spurny, F.; Vlcek, B.; Bamblevskij, V.P.; Timoshenko, G.N.

    1999-01-01

    A spectrometer of the linear energy transfer (LET) on the base of CR-39 detector was used to establish the spectra of LET in the beam of protons with the primary energy of 1 GeV. It was found out that the LET spectra of secondary charged particles between 100 and 7000 MeV cm 2 g -1 do not depend on the radiator. The average quality factors for the LET region mentioned were obtained about 11.6 with ICRP 26 quality factors and about 14.0 with ICRP 60 quality factors. The spectra obtained permitted to calculate the contributions of these secondary charged particles to the dosimetric quantities. It was observed that these contributions were about 7.0% for the total absorbed dose of protons and close 90% in the case of the equivalent doses. It is more than it was found out for few hundred MeV protons

  13. Contribution to the study of fluoride dosing by using a membrane selective electrode

    International Nuclear Information System (INIS)

    Rivas, Jean de

    1972-01-01

    As the method of dosing fluoride ions by precipitation with lead fluorochloride is not very satisfying, the author reports the study of a new process for the dosing of the fluorine ion by using a selective electrode. After some generalities on selective electrodes (principle, types, operation principle) and some recalls and definitions (Galvani and Volta potential, stability constants of complexes, principles of diffusion in solids), the author reports the study of the diffusion potential in glass membranes, the study of the membrane potential, and the study of the ion exchange equilibrium. He presents methods of calculation of selectivity coefficients of membrane electrodes, and the reports experiments performed in laboratory

  14. Effective collective dose imparted by a medicine nuclear service to Cordoba and Jaen populations

    International Nuclear Information System (INIS)

    Arias, M.C.; Galvez, M.; Torres, M.

    1997-01-01

    The application of diagnostic techniques in nuclear medicine is ever growing as part of clinical daily routine. Although the diagnostic procedures carry a negligible clinical risk, the introduction of radioactive substances into the patient makes it imperative to determine the effective dose to minimize the stochastic effects to the patient thus establishing the collective dose to the community. The aim of our work is to study the collective effective dose imparted by Nuclear Medicine Service during 1997 to Cordoba and Jaen inhabitants (1 448 988). The nuclear medicine techniques of bone exploration with 11 454 mSv-person (4,6 mSv/exploration) and thyroid scintigraphy with 6181 mSv-person (7,0 mSv /exploration) are the main techniques implicated in the relative contribution to the total annual effective collective dose of 35 901.2 mSv-person

  15. Image and dose quality in selected studies of conventional radiology in designed hospitals

    International Nuclear Information System (INIS)

    Cardenas H, J.; Martinez G, A.; Machado T, A.; Mora M, R. de la; Pedroso, L.; Villa Z, R.; Sotolongo C, J.A.; Rodriguez S, R.M.; Martinez A, U.; Figueroa G, L.M.

    2006-01-01

    The medical exposures have a significant contribution to the received doses by the population. As they generally contribute to the patient's direct benefit during a lot of time has been paid smaller attention that to other exposure forms, in spite of existing potentialities of reducing dose to the patients as consequence of these applications. In such sense in the last years the scientific community and international organizations have defined requirements to contribute to that the doses to the patients are the minimum ones necessary to achieve its diagnostic objective. The work exposes the results obtained in the evaluation of the image quality and dose in studies of radiology of thorax posteroanterior and of lumbosacral column anteroposterior and lateral, carried out in 2 university hospitals of La Havana, as well as the contribution of this investigation to the establishment of guidance levels in our country. (Author)

  16. Application of a Novel Dose-Uncertainty Model for Dose-Uncertainty Analysis in Prostate Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Jin Hosang; Palta, Jatinder R.; Kim, You-Hyun; Kim, Siyong

    2010-01-01

    Purpose: To analyze dose uncertainty using a previously published dose-uncertainty model, and to assess potential dosimetric risks existing in prostate intensity-modulated radiotherapy (IMRT). Methods and Materials: The dose-uncertainty model provides a three-dimensional (3D) dose-uncertainty distribution in a given confidence level. For 8 retrospectively selected patients, dose-uncertainty maps were constructed using the dose-uncertainty model at the 95% CL. In addition to uncertainties inherent to the radiation treatment planning system, four scenarios of spatial errors were considered: machine only (S1), S1 + intrafraction, S1 + interfraction, and S1 + both intrafraction and interfraction errors. To evaluate the potential risks of the IMRT plans, three dose-uncertainty-based plan evaluation tools were introduced: confidence-weighted dose-volume histogram, confidence-weighted dose distribution, and dose-uncertainty-volume histogram. Results: Dose uncertainty caused by interfraction setup error was more significant than that of intrafraction motion error. The maximum dose uncertainty (95% confidence) of the clinical target volume (CTV) was smaller than 5% of the prescribed dose in all but two cases (13.9% and 10.2%). The dose uncertainty for 95% of the CTV volume ranged from 1.3% to 2.9% of the prescribed dose. Conclusions: The dose uncertainty in prostate IMRT could be evaluated using the dose-uncertainty model. Prostate IMRT plans satisfying the same plan objectives could generate a significantly different dose uncertainty because a complex interplay of many uncertainty sources. The uncertainty-based plan evaluation contributes to generating reliable and error-resistant treatment plans.

  17. Epidemiological issues related to dose reconstruction

    International Nuclear Information System (INIS)

    Shore, R.E.

    1996-01-01

    When a dose reconstruction is performed around some nuclear site, a decision has to be made as to whether an epidemiologic study should be performed there and, if so, what form the study should take. The goal of this paper is to provide an overview of epidemiologic and biostatistical issues that help determine whether an epidemiologic study around a nuclear facility is worthwhile doing from a scientific standpoint. We are all aware that public health and sociopolitical concerns often assume considerable importance in these decisions, but they will not be considered here. 27 refs., 2 tabs

  18. Dose to red bone marrow of infants, children and adults from radiation of natural origin

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, G M [Childhood Cancer Research Group, University of Oxford, 57 Woodstock Road, Oxford OX2 6HJ (United Kingdom); Fell, T P; Harrison, J D [Health Protection Agency, Radiation Protection Division, CRCE, Chilton, Didcot OX11 0RQ, Oxon (United Kingdom)], E-mail: Gerald.Kendall@ccrg.ox.ac.uk

    2009-06-15

    Natural radiation sources contribute much the largest part of the radiation exposure of the average person. This paper examines doses from natural radiation to the red bone marrow, the tissue in which leukaemia is considered to originate, with particular emphasis on doses to children. The most significant contributions are from x-rays and gamma rays, radionuclides in food and inhalation of isotopes of radon and their decay products. External radiation sources and radionuclides other than radon dominate marrow doses at all ages. The variation with age of the various components of marrow dose is considered, including doses received in utero and in each year up to the age of 15. Doses in utero include contributions resulting from the ingestion of radionuclides by the mother and placental transfer to the foetus. Postnatal doses include those from radionuclides in breast-milk and from radionuclides ingested in other foods. Doses are somewhat higher in the first year of life and there is a general slow decline from the second year of life onwards. The low linear energy transfer (LET) component of absorbed dose to the red bone marrow is much larger than the high LET component. However, because of the higher radiation weighting factor for the latter it contributes about 40% of the equivalent dose incurred up to the age of 15.

  19. Cancer Control Related to Stimulation of Immunity by Low-Dose Radiation

    OpenAIRE

    Liu, Shu-Zheng

    2006-01-01

    Previous studies showed that low dose radiation (LDR) could stimulate the immune system in both animal and human populations. This paper reviews the present status of relevant research as support to the use of LDR in clinical practice for cancer prevention and treatment. It has been demonstrated that radiation-induced changes in immune activity follows an inverse J-shaped curve, i.e., low dose stimulation and high dose suppression. The stimulation of immunity by LDR concerns most anticancer p...

  20. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT

    Directory of Open Access Journals (Sweden)

    Małgorzata Wrzesień

    2017-10-01

    Full Text Available Objectives: Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT. Material and Methods: The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD in 18 anatomical points of the phantom. Results: The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions: Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5:705–713

  1. Dose-Related Differences in Effectiveness of Human Papillomavirus Vaccination Against Genital Warts

    DEFF Research Database (Denmark)

    Blomberg, Maria; Dehlendorff, Christian; Sand, Carsten

    2015-01-01

    BACKGROUND: Reducing the number of doses in the human papillomavirus (HPV) vaccination regimen from 3 to 2 could increase coverage rates. In this cohort study, we assessed the risk of genital warts (GWs) according to timing and number of doses of quadrivalent HPV vaccine. METHODS: From population......-based registries, we identified all girls in Denmark born during 1985-1999, for whom information on HPV vaccinations was retrieved. The cohort was followed for GW occurrence during 2006-2012. Incidence rate ratios (IRRs) were calculated by Poisson regression to determine differences in GW rates by number...... of vaccine doses. RESULTS: Of the 550,690 girls in the cohort, 361 734 had been vaccinated. Of these, 25.9% had been vaccinated twice and 58.8% 3 times. The risk of GWs decreased significantly with each additional dose of vaccine. For girls who received 2 doses, extension of the interval between doses...

  2. Contributions of the food irradiation technology to the nutritional and alimentary safety

    International Nuclear Information System (INIS)

    Ferreira, Sonia Regina Schauffert

    1999-01-01

    This work is a bibliographic review about the contributions of the food irradiation technology on nutritional and alimentary safety. Subjected to research and development for more than 60 years, these technology was approved by a jointly FAO/WHO/IAEA Expert Committees in 1980 with the conclusion that the irradiation of food up to an overall average dose of 10 kGy present no toxicological hazard and introduce no special nutritional or microbiological problems. Following these conclusions general standards and practices for food irradiation were adopted by the Codex Alimentarium Commission in 1983, opening the possibilities for internal applications and international commerce of irradiated food in many countries. Radiation from radioisotopes sources, electron accelerators or X-ray generators can be applied to food in order to reduce the microbial load, insect disinfestation, improving the shelf life extension of the products. Absorbed doses up to 10 kGy level do not introduce significant alterations in the macro or micro nutrients contents or in the sensorial characteristic of irradiated food. Although food safety can be related with many other important topics, irradiation technology improving food quality, reducing food spoilage during preservation and preventing problems related with food borne disease present a good potential to contribute with the foment and guaranty of the nutritional and alimentary safety. (author)

  3. Optically stimulated luminescence of common plastic materials for accident dose reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Chang, I.; Lee, J. I.; Kim, J. L. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Chung, K. S. [Gyeongsang National Univ., Jinju (Korea, Republic of)

    2014-05-15

    Optically stimulate luminescence(OSL) has many applications in a variety of radiation dosimetry fields, including personal dosimetry, environmental radiation level monitor, retrospective dosimetry for dating, and reconstruction of radiation doses from radiation accident. In the reconstruction of radiation doses from radiation accident, OSL technique has been used to estimate the doses exposed to public area through analysis of housewares or house construing materials. Recently, many efforts have been carried out for dose reconstruction using personal electronic devices such as mobile phones and USB memory chips. Some of natural minerals such as quartz and feldspar have OSL properties. Quartz is the second most abundant mineral in continental crust of the Earth. In some of common plastics, inorganic fillers (quartz, alumina etc.) are added to make strengthen of their properties depends on applications areas. The aim of this research is to explore a possibility of use of the common plastic materials for dose reconstruction in radiation accident case. In this research the OSL dose response-curve and fading characteristics of the common plastics were tested and evaluated. Finally, we expect this work contribute to elevate the possibility of the dose reconstruction. The general conclusion of this work is that the possibility of dose reconstruction using common plastic materials is showed using the OSL characteristics of the materials. However, the tested common plastic materials have relatively low sensitivities. Further work is required to establish a database of OSL properties of common plastic materials for emergency dose reconstruction by using housewares.

  4. Integral dose conservation in radiotherapy

    International Nuclear Information System (INIS)

    Reese, Adam S.; Das, Shiva K.; Curle, Charles; Marks, Lawrence B.

    2009-01-01

    Treatment planners frequently modify beam arrangements and use IMRT to improve target dose coverage while satisfying dose constraints on normal tissues. The authors herein analyze the limitations of these strategies and quantitatively assess the extent to which dose can be redistributed within the patient volume. Specifically, the authors hypothesize that (1) the normalized integral dose is constant across concentric shells of normal tissue surrounding the target (normalized to the average integral shell dose), (2) the normalized integral shell dose is constant across plans with different numbers and orientations of beams, and (3) the normalized integral shell dose is constant across plans when reducing the dose to a critical structure. Using the images of seven patients previously irradiated for cancer of brain or prostate cancer and one idealized scenario, competing three-dimensional conformal and IMRT plans were generated using different beam configurations. Within a given plan and for competing plans with a constant mean target dose, the normalized integral doses within concentric ''shells'' of surrounding normal tissue were quantitatively compared. Within each patient, the normalized integral dose to shells of normal tissue surrounding the target was relatively constant (1). Similarly, for each clinical scenario, the normalized integral dose for a given shell was also relatively constant regardless of the number and orientation of beams (2) or degree of sparing of a critical structure (3). 3D and IMRT planning tools can redistribute, rather than eliminate dose to the surrounding normal tissues (intuitively known by planners). More specifically, dose cannot be moved between shells surrounding the target but only within a shell. This implies that there are limitations in the extent to which a critical structure can be spared based on the location and geometry of the critical structure relative to the target.

  5. Dose-mapping distribution around MNSR

    CERN Document Server

    Jamal, M H

    2002-01-01

    The aim of this study is to establish the dose-rate map through the determination of radiological dose-rate levels in reactor hall, adjacent rooms, and outside the MNSR facility. Controlling dose rate to reactor operating personnel , dose map was established. The map covers time and distances in the reactor hall, during reactor operation at nominal power. Different measurement of dose rates in other areas of the reactor buildings was established. The maximum dose rate, during normal operation of the MNSR was 40 and 21 Sv/hr on the top of the reactor and near the pool fence, respectively. Whereas, gamma and neutron doses have not exceeded natural background in all rooms adjacent to the reactor hall or nearly buildings. The relation between the dose rate for gamma rays and neutron flux at the top of cover of reactor pool was studied as well. It was found that this relation is linear.

  6. Dose-mapping distribution around MNSR

    International Nuclear Information System (INIS)

    Jamal, M. H.; Khamis, I.

    2002-12-01

    The aim of this study is to establish the dose-rate map through the determination of radiological dose-rate levels in reactor hall, adjacent rooms, and outside the MNSR facility. Controlling dose rate to reactor operating personnel , dose map was established. The map covers time and distances in the reactor hall, during reactor operation at nominal power. Different measurement of dose rates in other areas of the reactor buildings was established. The maximum dose rate, during normal operation of the MNSR was 40 and 21 Sv/hr on the top of the reactor and near the pool fence, respectively. Whereas, gamma and neutron doses have not exceeded natural background in all rooms adjacent to the reactor hall or nearly buildings. The relation between the dose rate for gamma rays and neutron flux at the top of cover of reactor pool was studied as well. It was found that this relation is linear. (author)

  7. Absorbed dose by thyroid in case of nuclear accidents

    International Nuclear Information System (INIS)

    Campos, Laelia; Attie, Marcia Regina Pereira; Amaral, Ademir

    2011-01-01

    Radioisotopes of iodine are produced in abundance in nuclear fission reactions, and great amounts of radioiodine may be released into the environment in case of a nuclear reactor accident. Thyroid gland is among the most radiosensitive organs due to its capacity to concentrate iodine. The aim of this work was to evaluate the importance of contributions of internally deposited iodines ( 131 I, 132 I, 133 I, 134 I and 135 I) to the dose absorbed to thyroid follicle and to the whole organ, after internal contamination by those isotopes. For internal dose calculation, the code of particles transport MCNP4C was employed. The results showed that, in case of nuclear accidents, the contribution of short-lived iodines for total dose is about 45% for thyroid of newborn and about 40% for thyroid of adult. Thus, these contributions should not be neglected in a prospective evaluation of risks associated to internal contamination by radioactive iodine. (author)

  8. Cystic Fibrosis: Are Volumetric Ultra-Low-Dose Expiratory CT Scans Sufficient for Monitoring Related Lung Disease?

    DEFF Research Database (Denmark)

    Loeve, Martine; Lequin, Maarten H; Bruijne, Marleen de

    2009-01-01

    Purpose: To assess whether chest computed tomography (CT) scores from ultra-low-dose end-expiratory scans alone could suffice for assessment of all cystic fibrosis (CF)-related structural lung abnormalities. Materials and Methods: In this institutional review board–approved study, 20 patients...... with CF aged 6–20 years (eight males, 12 females) underwent low-dose end-inspiratory CT and ultra-low-dose end-expiratory CT. Informed consent was obtained. Scans were randomized and scored by using the Brody-II CT scoring system to assess bronchiectasis, airway wall thickening, mucus plugging......-Altman plots. Results: Median age was 12.6 years (range, 6.3–20.3 years), median forced expiratory volume in 1 second was 100% (range, 46%–127%) of the predicted value, and median forced vital capacity was 99% (range, 61%–123%) of the predicted value. Very good agreement was observed between end...

  9. Saving doses by outage planning strategy and architectural arrangements

    International Nuclear Information System (INIS)

    Wahlstroem, B.

    1993-01-01

    All radiation doses come out as a result of dose rate and exposure time, and the main part of the occupational exposure is caused during outages. While every reasonable attempt should be made to lower the dose rates, the other factor, the exposure time, may not be forgotten. The paper presents possible ways of saving man-hours in the controlled zone by outage planning strategy. And every saved man-hour means a saved radiation dose. At Loviisa NPS also some special architectural arrangements contribute to shortening the outage time, thus saving doses

  10. Howard Hughes Medical Institute dose assessment survey

    International Nuclear Information System (INIS)

    O'Brien, S.L.; McDougall, M.M.; Barkley, W.E.

    1996-01-01

    Biomedical science researchers often express frustration that health physics practices vary widely between individual institutions. A survey examining both internal and external dose assessment practices was devised and mailed to fifty institutions supporting biomedical science research. The results indicate that health physics dose assessment practices and policies are highly variable. Factors which may contribute to the degree of variation are discussed. 2 tabs

  11. A dose assessment for a U.S. nuclear test site -- Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1993-07-01

    On March 1, 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. Here the authors provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island. The unique composition of coral soil greatly alters the relative contribution of cesium-137 and strontium-90 to the total estimated dose relative to expectations based on North American and European soils. Cesium-137 produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The estimated maximum annual effective dose is 4.4 mSv y -1 when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 10 cSv, 14 cSv, and 16 cSv, respectively. An analysis of interindividual variability in 0- to 30-y expected integral dose indicates that 95% of Bikini residents would have expected doses within a factor of 3.4 above and 4.8 below the population-average value. A corresponding uncertainty analysis showed that after about 5 y of residence, the 95% confidence limits on population-average dose would be ±35% of its expected value. The authors have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to less than 10% of pretreatment levels and has essentially no negative environmental consequences

  12. Bioaccessibility of Fukushima-Accident-Derived Cs in Soils and the Contribution of Soil Ingestion to Radiation Doses in Children.

    Science.gov (United States)

    Takahara, Shogo; Ikegami, Maiko; Yoneda, Minoru; Kondo, Hitoshi; Ishizaki, Azusa; Iijima, Masashi; Shimada, Yoko; Matsui, Yasuto

    2017-07-01

    Ingestion of contaminated soil is one potential internal exposure pathway in areas contaminated by the Fukushima Daiichi Nuclear Power Plant accident. Doses from this pathway can be overestimated if the availability of radioactive nuclides in soils for the gastrointestinal tract is not considered. The concept of bioaccessibility has been adopted to evaluate this availability based on in vitro tests. This study evaluated the bioaccessibility of radioactive cesium from soils via the physiologically-based extraction test (PBET) and the extractability of those via an extraction test with 1 mol/L of hydrochloric acid (HCl). The bioaccessibility obtained in the PBET was 5.3% ± 1%, and the extractability in the tests with HCl was 16% ± 3%. The bioaccessibility was strongly correlated with the extractability. This result indicates the possibility that the extractability in HCl can be used as a good predictor of the bioaccessibility with PBET. In addition, we assessed the doses to children from the ingestion of soil via hand-to-mouth activity based on our PBET results using a probabilistic approach considering the spatial distribution of radioactive cesium in Date City in Fukushima Prefecture and the interindividual differences in the surveyed amounts of soil ingestion in Japan. The results of this assessment indicate that even if children were to routinely ingest a large amount of soil with relatively high contamination, the radiation doses from this pathway are negligible compared with doses from external exposure owing to deposited radionuclides in Fukushima Prefecture. © 2016 Society for Risk Analysis.

  13. Dose rate and fractionation: Relative importance in radiation for bone marrow transplantation

    International Nuclear Information System (INIS)

    Tarbell, N.J.; Rosenblatt, M.; Mauch, P.; Hellman, S.

    1987-01-01

    The optimal dose rate and fractionation schedules for total body irradiation (TBI) in bone marrow transplantation (BMT) are presently unknown. This study compares several fractionation and dose rate schedules that are currently in clinical use. C/sub 3/H/HeJ were given TBI and the bone marrow survival fraction was calculated using the CFU's assay. Irradiation was given as low dose rate (LDR) at 5 cGy/min or high dose rate (HDR) at 80 cGy/min, in single fraction (SF) and fractionated (FX) regimens. These results indicate no increase in survival for the normal bone marrow stem cells with fractionation either at high or low dose-rates. In fact, fractionation seemed to decrease the bone marrow survival over single fraction radiation

  14. The problem of the population dose

    International Nuclear Information System (INIS)

    Belyaev, V.A.

    1976-08-01

    This report investigates methods of calculating the population dose due to emissions from nuclear reactors. The exposure of the local population is considered as well as the exposure of the population of the remote area where food produced near the reactor site is consumed. Units of measurement for the population dose are discussed. A concrete example is given for calculating the contribution of isotopes of radioactive noble gases, 131 I and 137 Cs. (orig.) [de

  15. Three dimensional measurements of absorbed dose in BNCT by Fricke-gel imaging

    International Nuclear Information System (INIS)

    Gambarini, G.; Agosteo, S.; Marchesi, P.; Nava, E.; Palazzi, P.; Pecci, A.; Rosa, R.; Rosi, G.; Tinti, R.

    2001-01-01

    A method has been studied for absorbed dose imaging and profiling in a phantom exposed to thermal or epithermal neutron fields, also discriminating between various contributions to the absorbed dose. The proposed technique is based on optical imaging of FriXy-gel phantoms, which are proper tissue-equivalent phantoms acting as continuous dosimeters. Convenient modifications in phantom composition allow, from differential measurements, the discrimination of various contributions to the absorbed dose. The dosimetry technique is based on a chemical dosimeter incorporated in a tissue-equivalent gel (Agarose). The chemical dosimeter is a ferrous sulphate solution (which is the main component of the standard Fricke dosimeter) added with a metal ion indicator (Xylenol Orange). The absorbed dose is measured by analysing the variation of gel optical absorption in the visible spectrum, imaged by means of a CCD camera provided with a suitable filter. The technique validity has been tested by irradiating and analysing phantoms in the thermal facility of the fast research reactor TAPIRO (ENEA, Casaccia, Italy). In a cylindrical phantom simulating a head, we have imaged the therapy dose from thermal neutron reactions with 10 B and the dose in healthy tissue not containing boron. In tissue without boron, we have discriminated between the two main contributions to the absorbed dose, which comes from the 1 H(n,γ) 2 H and 14 N(n,p) 14 C reactions. The comparison with the results of other experimental techniques and of simulations reveals that the technique is very promising. A method for the discrimination of fast neutron contribution to the absorbed dose, still in an experimental stage, is proposed too. (author)

  16. Radiation dose reduction in chest CT—Review of available options

    International Nuclear Information System (INIS)

    Kubo, Takeshi; Ohno, Yoshiharu; Kauczor, Hans Ulrich; Hatabu, Hiroto

    2014-01-01

    Highlights: • The present status of proliferating CT examinations was presented. • Technical improvements of CT scanners for radiation dose reduction were reviewed. • Advantage and disadvantage of methods for CT radiation dose reduction were discussed. • Evidences for safety of CT radiation dose reduction were reviewed. - Abstract: Computed tomography currently accounts for the majority of radiation exposure related to medical imaging. Although technological improvement of CT scanners has reduced the radiation dose of individual examinations, the benefit was overshadowed by the rapid increase in the number of CT examinations. Radiation exposure from CT examination should be kept as low as reasonably possible for patient safety. Measures to avoid inappropriate CT examinations are needed. Principles and information on radiation dose reduction in chest CT are reviewed in this article. The reduction of tube current and tube potential are the mainstays of dose reduction methods. Study results indicate that routine protocols with reduced tube current are feasible with diagnostic results comparable to conventional standard dose protocols. Tube current adjustment is facilitated by the advent of automatic tube current modulation systems by setting the appropriate image quality level for the purpose of the examination. Tube potential reduction is an effective method for CT pulmonary angiography. Tube potential reduction often requires higher tube current for satisfactory image quality, but may still contribute to significant radiation dose reduction. Use of lower tube potential also has considerable advantage for smaller patients. Improvement in image production, especially the introduction of iterative reconstruction methods, is expected to lower radiation dose significantly. Radiation dose reduction in CT is a multifaceted issue. Understanding these aspects leads to an optimal solution for various indications of chest CT

  17. Radiation dose reduction in chest CT—Review of available options

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Takeshi, E-mail: tkubo@kuhpkyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan); Kauczor, Hans Ulrich, E-mail: hu.kauczor@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Clinic Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Hatabu, Hiroto, E-mail: hhatabu@partners.org [Department of Radiology, Brigham and Women' s Hospital, 75 Francis Street, Boston, MA 02115 (United States)

    2014-10-15

    Highlights: • The present status of proliferating CT examinations was presented. • Technical improvements of CT scanners for radiation dose reduction were reviewed. • Advantage and disadvantage of methods for CT radiation dose reduction were discussed. • Evidences for safety of CT radiation dose reduction were reviewed. - Abstract: Computed tomography currently accounts for the majority of radiation exposure related to medical imaging. Although technological improvement of CT scanners has reduced the radiation dose of individual examinations, the benefit was overshadowed by the rapid increase in the number of CT examinations. Radiation exposure from CT examination should be kept as low as reasonably possible for patient safety. Measures to avoid inappropriate CT examinations are needed. Principles and information on radiation dose reduction in chest CT are reviewed in this article. The reduction of tube current and tube potential are the mainstays of dose reduction methods. Study results indicate that routine protocols with reduced tube current are feasible with diagnostic results comparable to conventional standard dose protocols. Tube current adjustment is facilitated by the advent of automatic tube current modulation systems by setting the appropriate image quality level for the purpose of the examination. Tube potential reduction is an effective method for CT pulmonary angiography. Tube potential reduction often requires higher tube current for satisfactory image quality, but may still contribute to significant radiation dose reduction. Use of lower tube potential also has considerable advantage for smaller patients. Improvement in image production, especially the introduction of iterative reconstruction methods, is expected to lower radiation dose significantly. Radiation dose reduction in CT is a multifaceted issue. Understanding these aspects leads to an optimal solution for various indications of chest CT.

  18. Investigation on contribution of neutron monitor data to estimation of aviation doses

    Czech Academy of Sciences Publication Activity Database

    Kákona, Martin; Ploc, Ondřej; Kyselová, Dagmar; Kubančák, Ján; Langer, R.; Kudela, K.

    2016-01-01

    Roč. 11, NOV (2016), s. 24-28 ISSN 2214-5524 Grant - others:AV ČR SAV-15-19 Program:Bilaterální spolupráce Institutional support: RVO:61389005 Keywords : radiation dose on aircraft * cosmic rays measured on ground Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  19. 90Y/90 Sr electron induced damages in an essential eucalyptus oil related to the absorbed dose

    International Nuclear Information System (INIS)

    Heredia Cardona, J.A.; Diaz Rizo, O.; Martinez Luzardo, F.; Quert, R.

    2007-01-01

    A good irradiation geometry was achieved in order to carry out the irradiation of an essential eucalyptus oil with a 90 Y/ 90 Sr electron source. The Monte Carlo simulation code MCNP-4C was employed to determine the absorbed doses in this particular experimental configuration. It also helped us to understand which electrons (from an energetic point of view) were responsible for the damages. In order to identify the induced damages, the irradiated samples were studied by mass spectrometry. The obtained results were related to the absorbed doses determined by the computational simulation

  20. Airborne and total gamma absorbed dose rates at Patiala - India

    International Nuclear Information System (INIS)

    Tesfaye, Tilahun; Sahota, H.S.; Singh, K.

    1999-01-01

    The external gamma absorbed dose rate due to gamma rays originating from gamma emitting aerosols in air, is compared with the total external gamma absorbed dose rate at the Physics Department of Punjabi University, Patiala. It has been found out that the contribution, to the total external gamma absorbed dose rate, of radionuclides on particulate matter suspended in air is about 20% of the overall gamma absorbed dose rate. (author)

  1. Dose due to man-made radionuclides in terrestrial wild foods near Sellafield

    International Nuclear Information System (INIS)

    Fulker, M.J.; Jackson, D.; McKay, K.; John, C.; Leonard, D.R.P.

    1998-01-01

    Radiological dose implications for consumers of wild foods around Sellafield have been assessed. Habits were surveyed from 72 households, mostly within a few kilometres of Sellafield. A few people were included who lived further away but collect wild foods close to Sellafield. Dose estimates were based on measured gamma emitters, as well as 239 Pu, 241 Am, 14 C and 129 I in selected samples. In all cases, doses were dominated by 137 Cs. One infant was identified who consumed wild food, giving an estimated effective dose of 0.3 μSv a -1 . In the age group 2 to 10 years a mean dose of 0.51 μSv a -1 , and a maximum of 2.8 μSv a -1 , were estimated. Intakes by adults were higher and resulted in more radiologically significant doses. The extreme individual received a dose of 32 μSv a -1 largely due to consumption of honey that included contributions from the Chernobyl accident, and hedgerow fruits. This is comparable to doses to the critical group for consumption of conventional agricultural produce close to the Sellafield site. The 97.5th percentile dose, for all age groups of consumers taken together, was 16.6 μSv a -1 , or 6.2 μSv a -1 if the contributions from Chernobyl are excluded. Considering the contributions from different foods to the whole group of 181 wild food consumers, the rank order is honey, blackberries and venison. (author)

  2. Familial aggregation of gout and relative genetic and environmental contributions: a nationwide population study in Taiwan.

    Science.gov (United States)

    Kuo, Chang-Fu; Grainge, Matthew J; See, Lai-Chu; Yu, Kuang-Hui; Luo, Shue-Fen; Valdes, Ana M; Zhang, Weiya; Doherty, Michael

    2015-02-01

    To examine familial aggregation of gout and to estimate the heritability and environmental contributions to gout susceptibility in the general population. Using data from the National Health Insurance (NHI) Research Database in Taiwan, we conducted a nationwide cross-sectional study of data collected from 22 643 748 beneficiaries of the NHI in 2004; among them 1 045 059 individuals had physician-diagnosed gout. We estimated relative risks (RR) of gout in individuals with affected first-degree and second-degree relatives and relative contributions of genes (heritability), common environment shared by family members and non-shared environment to gout susceptibility. RRs for gout were significantly higher in individuals with affected first-degree relatives (men, 1.91 (95% CI 1.90 to 1.93); women, 1.97 (95% CI 1.94 to 1.99)) and also in those with affected second-degree relatives (men, 1.27 (95% CI 1.23 to 1.31); women, 1.40 (95% CI 1.35 to 1.46)). RRs (95% CIs) for individuals with an affected twin, sibling, offspring, parent, grandchild, nephew/niece, uncle/aunt and grandparent were 8.02 (6.95 to 9.26), 2.59 (2.54 to 2.63), 1.96 (1.95 to 1.97), 1.93 (1.91 to 1.94), 1.48 (1.43 to 1.53), 1.40 (1.32 to 1.47), 1.31 (1.24 to 1.39), and 1.26 (1.21 to 1.30), respectively. The relative contributions of heritability, common and non-shared environmental factors to phenotypic variance of gout were 35.1, 28.1 and 36.8% in men and 17.0, 18.5 and 64.5% in women, respectively. This population-based study confirms that gout aggregates within families. The risk of gout is higher in people with a family history. Genetic and environmental factors contribute to gout aetiology, and the relative contributions are sexually dimorphic. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Adipocyte-derived factors in age-related dementia and their contribution to vascular and Alzheimer pathology.

    Science.gov (United States)

    Ishii, Makoto; Iadecola, Costantino

    2016-05-01

    Age-related dementia is increasingly recognized as having a mixed pathology, with contributions from both cerebrovascular factors and pathogenic factors associated with Alzheimer's disease (AD). Furthermore, there is accumulating evidence that vascular risk factors in midlife, e.g., obesity, diabetes, and hypertension, increase the risk of developing late-life dementia. Since obesity and changes in body weight/adiposity often drive diabetes and hypertension, understanding the relationship between adiposity and age-related dementia may reveal common underlying mechanisms. Here we offer a brief appraisal of how changes in body weight and adiposity are related to both AD and dementia on vascular basis, and examine the involvement of two key adipocyte-derived hormones: leptin and adiponectin. The evidence suggests that in midlife increased body weight/adiposity and subsequent changes in adipocyte-derived hormones may increase the long-term susceptibility to dementia. On the other hand, later in life, decreases in body weight/adiposity and related hormonal changes are early manifestations of disease that precede the onset of dementia and may promote AD and vascular pathology. Understanding the contribution of adiposity to age-related dementia may help identify the underlying pathological mechanisms common to both vascular dementia and AD, and provide new putative targets for early diagnosis and therapy. This article is part of a Special Issue entitled: Vascular Contributions to Cognitive Impairment and Dementia, edited by M. Paul Murphy, Roderick A. Corriveau and Donna M. Wilcock. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. DFT/GIAO calculations of the relative contributions of hyperconjugation to the chemical shifts of ethanol

    International Nuclear Information System (INIS)

    Carneiro, J. Walkimar de M.; Dias, Jacques F.; Seidl, Peter R.; Tostes, J. Glauco R.

    2002-01-01

    Our previous DFT/GIAO calculations on different types of alcohols reveal that the rotation of the hydroxyl group can affect the chemical shift of carbons and hydrogens close to the substituent in different ways. Besides the steric and electrostatic effects that have been widely studied, hyperconjugation with the lone pairs on oxygen of the hydroxyl group leads to changes in bond lengths and angles as well as to different charge distributions. As all three of these factors also affect chemical shifts, we undertook a systematic investigation of their relative contributions to the chemical shifts of ethanol, a molecule in which there is minimum interference among these factors. Calculations by the B3LYP method at the 6-31G(d) level for ethanol conformers corresponding to a rotation around the carbon-oxygen bond at 30 dec increments are used to show how relative contributions vary with the dihedral angle formed between the carbon-carbon and oxygen-hydrogen bonds (C-C-O-H). Largest contributions to carbon chemical shifts can be attributed to changes in bond lengths while for hydrogen chemical shifts also contribute significantly differences in charge distribution. (author)

  5. Prediction of terrestrial gamma dose rate based on geological formations and soil types in the Johor State, Malaysia

    International Nuclear Information System (INIS)

    Saleh, Muneer Aziz; Ramli, Ahmad Termizi; Hamzah, Khaidzir bin; Alajerami, Yasser; Moharib, Mohammed; Saeed, Ismael

    2015-01-01

    This study aims to predict and estimate unmeasured terrestrial gamma dose rate (TGDR) using statistical analysis methods to derive a model from the actual measurement based on geological formation and soil type. The measurements of TGDR were conducted in the state of Johor with a total of 3873 measured points which covered all geological formations, soil types and districts. The measurements were taken 1 m above the soil surface using NaI [Ti] detector. The measured gamma dose rates ranged from 9 nGy h −1 to 1237 nGy h −1 with a mean value of 151 nGy h −1 . The data have been normalized to fit a normal distribution. Tests of significance were conducted among all geological formations and soil types, using the unbalanced one way ANOVA. The results indicated strong significant differences due to the different geological formations and soil types present in Johor State. Pearson Correlation was used to measure the relations between gamma dose rate based on geological formation and soil type (D G,S ) with the gamma dose rate based on geological formation (D G ) or soil type (D s ). A very good correlation was found between D G,S and D G or D G,S and D s . A total of 118 pairs of geological formations and soil types were used to derive the statistical contribution of geological formations and soil types to gamma dose rates. The contribution of the gamma dose rate from geological formation and soil type were found to be 0.594 and 0.399, respectively. The null hypotheses were accepted for 83% of examined data, therefore, the model could be used to predict gamma dose rates based on geological formation and soil type information. - Highlights: • A very good correlation coefficient was found between D G,S and D G or D G,S and D s . • The contribution of the gamma dose rate from geological formation (GDR) is 0.594. • The contribution of the GDR from soil type was found to be 0.399. • A 83% of examined data were accepted the null hypotheses. • The model

  6. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C.

    2015-01-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  7. Pilot study: relative dose of the TLD, OSL and Radiochromic film applied in CT exams dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F. [Universidade Federal do Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil). Hospital Universitario Maria Aparecida Pedrossian; Maia, R.S.I.; Romano, R.F.T.; Daros, K. A.C., E-mail: daros.kellen@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Departamento de Diagnostico por Imagem

    2015-07-01

    At DDI/UNIFESP, the abdomen and chest CT exams correspond to 38% of the exams, becoming the focus of studies. The aim of this study is to assess the relative dose using TLDs, OSLs and RF for the evaluation of the dose distribution in the skin in abdomen CT exams. The simulation of the CT exam was performed in an anthropomorphic phantom, using a CT scanner Philips, Brilliance/64 and TLDs, OSLs and RF fixed along the sagittal axis of the phantom. The OSLs showed similar performance to the TLDs and RF shows low accuracy, resulting in an average value (0.927±0.022). (author)

  8. Method for calculating individual equivalent doses and cumulative dose of population in the vicinity of nuclear power plant site

    International Nuclear Information System (INIS)

    Namestek, L.; Khorvat, D; Shvets, J.; Kunz, Eh.

    1976-01-01

    A method of calculating the doses of external and internal person irradiation in the nuclear power plant vicinity under conditions of normal operation and accident situations has been described. The main difference between the above method and methods used up to now is the use of a new antropomorphous representation of a human body model together with all the organs. The antropomorphous model of human body and its organs is determined as a set of simple solids, coordinates of disposistion of the solids, sizes, masses, densities and composition corresponding the genuine organs. The use of the Monte-Carlo method is the second difference. The results of the calculations according to the model suggested can be used for determination: a critical group of inhabitans under conditions of normal plant operation; groups of inhabitants most subjected to irradiation in the case of possible accident; a critical sector with a maximum collective dose in the case of an accident; a critical radioisotope favouring the greatest contribution to an individual equivalent dose; critical irradiation ways promoting a maximum contribution to individual equivalent doses; cumulative collective doses for the whole region or for a chosen part of the region permitting to estimate a population dose. The consequent method evoluation suggests the development of separate units of the calculationg program, critical application and the selection of input data of physical, plysiological and ecological character and improvement of the calculated program for the separate concrete events [ru

  9. Biological effects of low-dose ionizing radiation exposure; Biologische Wirkungen niedriger Dosen ionisierender Strahlung

    Energy Technology Data Exchange (ETDEWEB)

    Reinoehl-Kompa, Sabine; Baldauf, Daniela; Heller, Horst (comps.)

    2009-07-01

    The report on the meeting of the Strahlenschutzkommission 2007 concerning biological effects of low-dose ionizing radiation exposure includes the following contributions: Adaptive response. The importance of DNA damage mechanisms for the biological efficiency of low-energy photons. Radiation effects in mammography: the relative biological radiation effects of low-energy photons. Radiation-induced cataracts. Carcinomas following prenatal radiation exposure. Intercellular apoptosis induction and low-dose irradiation: possible consequences for the oncogenesis control. Mechanistic models for the carcinogenesis with radiation-induced cell inactivation: application to all solid tumors in the Japanese atomic bomb survivors. Microarrays at low radiation doses. Mouse models for the analysis of biological effects of low-dose ionizing radiation. The bystander effect: observations, mechanisms and implications. Lung carcinoma risk of Majak workers - modeling of carcinogenesis and the bystander effect. Microbeam studies in radiation biology - an overview. Carcinogenesis models with radiation-induced genomic instability. Application to two epidemiological cohorts.

  10. Radiation Dose to the Esophagus From Breast Cancer Radiation Therapy, 1943-1996: An International Population-Based Study of 414 Patients

    International Nuclear Information System (INIS)

    Lamart, Stephanie; Stovall, Marilyn; Simon, Steven L.; Smith, Susan A.; Weathers, Rita E.; Howell, Rebecca M.; Curtis, Rochelle E.; Aleman, Berthe M.P.; Travis, Lois; Kwon, Deukwoo; Morton, Lindsay M.

    2013-01-01

    Purpose: To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. Methods and Materials: We abstracted the radiation therapy treatment parameters from each patient’s radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were 60 Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Results: Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Conclusions: Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower doses

  11. Radiation dose to the esophagus from breast cancer radiation therapy, 1943-1996: an international population-based study of 414 patients.

    Science.gov (United States)

    Lamart, Stephanie; Stovall, Marilyn; Simon, Steven L; Smith, Susan A; Weathers, Rita E; Howell, Rebecca M; Curtis, Rochelle E; Aleman, Berthe M P; Travis, Lois; Kwon, Deukwoo; Morton, Lindsay M

    2013-07-15

    To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. We abstracted the radiation therapy treatment parameters from each patient's radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were (60)Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower doses. Published by Elsevier Inc.

  12. Radiation Dose to the Esophagus From Breast Cancer Radiation Therapy, 1943-1996: An International Population-Based Study of 414 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lamart, Stephanie, E-mail: stephanie.lamart@nih.gov [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Stovall, Marilyn [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Simon, Steven L. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Smith, Susan A.; Weathers, Rita E.; Howell, Rebecca M. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Curtis, Rochelle E. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Aleman, Berthe M.P. [Department of Radiotherapy, The Netherlands Cancer Institute, Amsterdam (Netherlands); Travis, Lois [Rubin Center for Cancer Survivorship and Department of Radiation Oncology, University of Rochester Medical Center, Rochester, New York (United States); Kwon, Deukwoo [Sylvester Comprehensive Cancer Center, University of Miami, Miami, Florida (United States); Morton, Lindsay M. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States)

    2013-07-15

    Purpose: To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. Methods and Materials: We abstracted the radiation therapy treatment parameters from each patient’s radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were {sup 60}Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Results: Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Conclusions: Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower

  13. Radiation dose in CT are meeting the challenge

    International Nuclear Information System (INIS)

    Wang Jun

    2003-01-01

    Despite comprising only 2% of all examinations, CT contributed around 20% of the collective dose to the population from diagnostic imaging. An abdominal examination in an adult with an effective dose of 10 mSv has been estimated to increase the lifetime risk of fatal cancer by 1 in 2000. Children are 10 times more sensitive to the effects of radiation than middle aged adults. Girls are more sensitive than boys. Variations in CT practice, ease of using, urgency in multislice CT, unawaring of the 'uncoupling effect' in CT may be contributing to increasing in radiation dose. We must train and have an awareness of emerging materials and the implied changes in practice, with revision of protocols to take account of advances. The 'as low as reasonably achievable (ALARA) ' principle applies just as much to CT as it does to conventional radiography

  14. Three-dimensional dose-response models of competing risks and natural life span

    International Nuclear Information System (INIS)

    Raabe, O.G.

    1987-01-01

    Three-dimensional dose-rate/time/response surfaces for chronic exposure to carcinogens, toxicants, and ionizing radiation dramatically clarify the separate and interactive roles of competing risks. The three dimensions are average dose rate, exposure time, and risk. An illustration with computer graphics shows the contributions with the passage of time of the competing risks of death from radiation pneumonitis/fibrosis, lung cancer, and natural aging consequent to the inhalation of plutonium-239 dioxide by beagles. These relationships are further evaluated by mathematical stripping with three-dimensional illustrations that graphically show the resultant separate contribution of each fatal effect. Radiation pneumonitis predominates at high dose rates and lung cancer at intermediate dose rates. Low dose rates result in spontaneous deaths from natural aging, yielding a type of practical threshold for lung cancer induction. Risk assessment is benefited by the insights that become apparent with these three-dimensional models. The improved conceptualization afforded by them contributes to the planning and evaluation of epidemiological analyses and experimental studies involving chronic exposure to toxicants

  15. Clinical and virological effects of high-dose recombinant interferon-alpha in disseminated AIDS-related Kaposi's sarcoma

    NARCIS (Netherlands)

    de Wit, R.; Schattenkerk, J. K.; Boucher, C. A.; Bakker, P. J.; Veenhof, K. H.; Danner, S. A.

    1988-01-01

    The effectiveness and antiretroviral activities of interferon-alpha in AIDS-related Kaposi's sarcoma was assessed in a non-randomised, phase-II clinical trial. 28 patients were treated with high-dose (27-36 MU) human recombinant interferon-alpha 2a subcutaneously every day for 8 weeks. In patients

  16. Contributions of secondary fragmentation by carbon ion beams in water phantom: Monte Carlo simulation

    International Nuclear Information System (INIS)

    Ying, C K; Bolst, David; Tran, Linh T.; Guatelli, Susanna; Rosenfeld, A. B.; Kamil, W A

    2017-01-01

    Heavy-particle therapy such as carbon ion therapy is currently very popular because of its superior conformality in terms of dose distribution and higher Relative Biological Effectiveness (RBE). However, carbon ion beams produce a complex mixed radiation field, which needs to be fully characterised. In this study, the fragmentation of a 290 MeV/u primary carbon ion beam was studied using the Geant4 Monte Carlo Toolkit. When the primary carbon ion beam interacts with water, secondary light charged particles (H, He, Li, Be, B) and fast neutrons are produced, contributing to the dose, especially after the distal edge of the Bragg peak. (paper)

  17. Psilocybin occasioned mystical-type experiences: immediate and persisting dose-related effects.

    Science.gov (United States)

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; McCann, Una; Jesse, Robert

    2011-12-01

    This dose-effect study extends previous observations showing that psilocybin can occasion mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. This double-blind study evaluated psilocybin (0, 5, 10, 20, 30 mg/70 kg, p.o.) administered under supportive conditions. Participants were 18 adults (17 hallucinogen-naïve). Five 8-h sessions were conducted individually for each participant at 1-month intervals. Participants were randomized to receive the four active doses in either ascending or descending order (nine participants each). Placebo was scheduled quasi-randomly. During sessions, volunteers used eyeshades and were instructed to direct their attention inward. Volunteers completed questionnaires assessing effects immediately after and 1 month after each session, and at 14 months follow-up. Psilocybin produced acute perceptual and subjective effects including, at 20 and/or 30 mg/70 kg, extreme anxiety/fear (39% of volunteers) and/or mystical-type experience (72% of volunteers). One month after sessions at the two highest doses, volunteers rated the psilocybin experience as having substantial personal and spiritual significance, and attributed to the experience sustained positive changes in attitudes, mood, and behavior, with the ascending dose sequence showing greater positive effects. At 14 months, ratings were undiminished and were consistent with changes rated by community observers. Both the acute and persisting effects of psilocybin were generally a monotonically increasing function of dose, with the lowest dose showing significant effects. Under supportive conditions, 20 and 30 mg/70 kg psilocybin occasioned mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. Implications for therapeutic trials are discussed.

  18. Motivations for contributing to health-related articles on Wikipedia: an interview study.

    Science.gov (United States)

    Farič, Nuša; Potts, Henry W W

    2014-12-03

    Wikipedia is one of the most accessed sources of health information online. The current English-language Wikipedia contains more than 28,000 articles pertaining to health. The aim was to characterize individuals' motivations for contributing to health content on the English-language Wikipedia. A set of health-related articles were randomly selected and recent contributors invited to complete an online questionnaire and follow-up interview (by Skype, by email, or face-to-face). Interviews were transcribed and analyzed using thematic analysis and a realist grounded theory approach. A total of 32 Wikipedians (31 men) completed the questionnaire and 17 were interviewed. Those completing the questionnaire had a mean age of 39 (range 12-59) years; 16 had a postgraduate qualification, 10 had or were currently studying for an undergraduate qualification, 3 had no more than secondary education, and 3 were still in secondary education. In all, 15 were currently working in a health-related field (primarily clinicians). The median period for which they have been an active editing Wikipedia was 3-5 years. Of this group, 12 were in the United States, 6 were in the United Kingdom, 4 were in Canada, and the remainder from another 8 countries. Two-thirds spoke more than 1 language and 90% (29/32) were also active contributors in domains other than health. Wikipedians in this study were identified as health professionals, professionals with specific health interests, students, and individuals with health problems. Based on the interviews, their motivations for editing health-related content were summarized in 5 strongly interrelated categories: education (learning about subjects by editing articles), help (wanting to improve and maintain Wikipedia), responsibility (responsibility, often a professional responsibility, to provide good quality health information to readers), fulfillment (editing Wikipedia as a fun, relaxing, engaging, and rewarding activity), and positive attitude to

  19. Report of task group on the biological basis for dose limitation in the skin

    International Nuclear Information System (INIS)

    1989-08-01

    Researchers have drawn attention to what they consider inconsistencies in the manner in which ICRP have considered skin in relation to the effective dose equivalent. They urge that the dose to the skin should be considered routinely for inclusion in the effective dose equivalent in the context of protection of individuals and population groups. They note that even with a weighting factor of only 0.01 that the dose to the skin can be a significant contributor to the effective dose equivalent including skin for practical exposure conditions. In the case of many exposures the risk to the skin can be ignored but exposure in an uniformly contaminated cloud that might occur with 85 Kr the dose to the skin could contribute 60% of the stochastic risk if included in the effective dose equivalent with a W T of 0.01. Through the years and even today the same questions about radiation effects in the skin and dosimetry keep being asked. This report collates the available data and current understanding of radiation effects on the skin, and may make it possible to estimate risks more accurately and to improve the approach to characterizing skin irradiations. 294 refs., 29 figs

  20. Modeling low-dose-rate effects in irradiated bipolar-base oxides

    International Nuclear Information System (INIS)

    Graves, R.J.; Cirba, C.R.; Schrimpf, R.D.; Milanowski, R.J.; Saigne, F.; Michez, A.; Fleetwood, D.M.; Witczak, S.C.

    1997-02-01

    A physical model is developed to quantify the contribution of oxide-trapped charge to enhanced low-dose-rate gain degradation in BJTs. Simulations show that space charge limited transport is partially responsible for the low-dose-rate enhancement

  1. Patient absorbed radiation doses estimation related to irradiation anatomy; Estimativa de dose absorvida pelo paciente relacionada a anatomia irradiada

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Flavio Augusto Penna; Soares, Amanda Anastacio; Kahl, Gabrielly Gomes, E-mail: prof.flavio@gmail.com, E-mail: amanda-a-soares@hotmail.com, E-mail: gabriellygkahl@gmail.com [Instituto Federal de Eduacao, Ciencia e Tecnologia de Santa Catarina (IFSC), Florianopolis, SC (Brazil)

    2014-07-01

    Developed a direct equation to estimate the absorbed dose to the patient in x-ray examinations, using electric, geometric parameters and filtering combined with data from irradiated anatomy. To determine the absorbed dose for each examination, the entrance skin dose (ESD) is adjusted to the thickness of the patient's specific anatomy. ESD is calculated from the estimated KERMA greatness in the air. Beer-Lambert equations derived from power data mass absorption coefficients obtained from the NIST / USA, were developed for each tissue: bone, muscle, fat and skin. Skin thickness was set at 2 mm and the bone was estimated in the central ray of the site, in the anteroposterior view. Because they are similar in density and attenuation coefficients, muscle and fat are treated as a single tissue. For evaluation of the full equations, we chose three different anatomies: chest, hand and thigh. Although complex in its shape, the equations simplify direct determination of absorbed dose from the characteristics of the equipment and patient. The input data is inserted at a single time and total absorbed dose (mGy) is calculated instantly. The average error, when compared with available data, is less than 5% in any combination of device data and exams. In calculating the dose for an exam and patient, the operator can choose the variables that will deposit less radiation to the patient through the prior analysis of each combination of variables, using the ALARA principle in routine diagnostic radiology sector.

  2. Radiation-related damage to the developing human brain

    International Nuclear Information System (INIS)

    Schull, W.J.; Yoshimaru, Hiroshi; Kyorin Univ., Tokyo

    1989-01-01

    The authors summarize the significant dose-related effects on brain development which have emerged largely within the last six years of study of prenatally exposed A-bomb survivors. The results are described primarily in terms of the DS86 estimates and differences between these and the older T65DR dose estimates are discussed. The severe mental retardation sample was based on 1598 individuals taken from the PE-86 sample, and the intelligence test scores considered from the same sample involved 1673 children. The authors also discuss some of the recent neurobiological developments that appear relevant to an understanding of the biological bases of dose-related events observed, and suggest future research that may contribute either to further delineation of exposure consequences or to the explanation of the cellular and molecular origins of observed effects. (UK)

  3. Main clinical, therapeutic and technical factors related to patient's maximum skin dose in interventional cardiology procedures

    Science.gov (United States)

    Journy, N; Sinno-Tellier, S; Maccia, C; Le Tertre, A; Pirard, P; Pagès, P; Eilstein, D; Donadieu, J; Bar, O

    2012-01-01

    Objective The study aimed to characterise the factors related to the X-ray dose delivered to the patient's skin during interventional cardiology procedures. Methods We studied 177 coronary angiographies (CAs) and/or percutaneous transluminal coronary angioplasties (PTCAs) carried out in a French clinic on the same radiography table. The clinical and therapeutic characteristics, and the technical parameters of the procedures, were collected. The dose area product (DAP) and the maximum skin dose (MSD) were measured by an ionisation chamber (Diamentor; Philips, Amsterdam, The Netherlands) and radiosensitive film (Gafchromic; International Specialty Products Advanced Materials Group, Wayne, NJ). Multivariate analyses were used to assess the effects of the factors of interest on dose. Results The mean MSD and DAP were respectively 389 mGy and 65 Gy cm−2 for CAs, and 916 mGy and 69 Gy cm−2 for PTCAs. For 8% of the procedures, the MSD exceeded 2 Gy. Although a linear relationship between the MSD and the DAP was observed for CAs (r=0.93), a simple extrapolation of such a model to PTCAs would lead to an inadequate assessment of the risk, especially for the highest dose values. For PTCAs, the body mass index, the therapeutic complexity, the fluoroscopy time and the number of cine frames were independent explanatory factors of the MSD, whoever the practitioner was. Moreover, the effect of technical factors such as collimation, cinematography settings and X-ray tube orientations on the DAP was shown. Conclusion Optimising the technical options for interventional procedures and training staff on radiation protection might notably reduce the dose and ultimately avoid patient skin lesions. PMID:22457404

  4. I-125 seed dose estimates in heterogeneous phantom

    International Nuclear Information System (INIS)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio

    2015-01-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  5. I-125 seed dose estimates in heterogeneous phantom

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio, E-mail: isabela.slbranco@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  6. Dose-dependent effect of ghrelin on gastric emptying in rats and the related mechanism of action

    Directory of Open Access Journals (Sweden)

    Shu-Guang Cao

    2016-03-01

    Full Text Available The aim of this study was to investigate the dose-dependent effect of ghrelin on gastric emptying in rats and the related mechanism of action. Sixty Wistar rats were randomized into control and test groups, which respectively received intraperitoneal injection of normal saline and ghrelin at different doses (0.5 nmol/kg, 1.0 nmol/kg, 1.5 nmol/kg, 2.0 nmol/kg, and 2.5 nmol/kg. After 45 minutes, all rats were gavaged with semisolid paste. The gastric emptying rate was determined 30 minutes later, and the plasma cholecystokinin level was tested by radioimmunoassay. The mean gastric emptying rate in the test groups was significantly higher than in the control group (38.24 ± 7.15% and 27.18 ± 2.37%, respectively, p < 0.05. Medium and high doses of ghrelin (1.0 nmol/kg, 1.5 nmol/kg, 2.0 nmol/kg, and 2.5 nmol/kg, but not low dose (0.5 nmol/kg, accelerated the gastric emptying. In addition, the plasma cholecystokinin level in the test groups was significantly higher than in the control group (p < 0.01. The gastric emptying rate was positively correlated with the plasma cholecystokinin level (p < 0.01. Intraperitoneal injection of ghrelin at medium and high doses significantly accelerated gastric emptying in rats.

  7. Contribution of internal exposures to the radiological consequences of the Chernobyl accident.

    Science.gov (United States)

    Balonov, M I; Anspaugh, L R; Bouville, A; Likhtarev, I A

    2007-01-01

    The main pathways leading to exposure of members of the general public due to the Chernobyl accident were external exposure from radionuclides deposited on the ground and ingestion of contaminated terrestrial food products. The collective dose to the thyroid was nearly 1.5 million man Gy in Belarus, Russia and Ukraine with nearly half received by children and adolescents. The collective effective dose received in 1986-2005 by approximately five million residents living in the affected areas of the three countries was approximately 50,000 man Sv with approximately 40% from ingestion. That contribution might have been larger if countermeasures had not been applied. The main radionuclide contributing to both external and internal effective dose is 137Cs with smaller contributions of 134Cs and 90Sr and negligible contribution of transuranic elements. The major demonstrated radiation-caused health effect of the Chernobyl accident has been an elevated incidence of thyroid cancer in children.

  8. Paediatric doses from diagnostic radiology in Victoria

    International Nuclear Information System (INIS)

    Boal, T.J.; Cardillo, I.; Einsiedel, P.F.

    1998-01-01

    This study examines doses to paediatric patients from diagnostic radiology. Measurements were made at 29 hospitals and private radiology practices in the state of Victoria. Entrance skin doses in air were measured for the exposure factors used by hospital radiology departments and private radiology practices for a standard size 1, 5, 10 and 15 year old child, for the following procedures: chest AP/PA, lat; abdomen AP; pelvis AP; lumbar spine AP, lat; and skull AP, lat. There was a large range of doses for each particular procedure and age group. Factors contributing to the range of doses were identified. Guidance levels for paediatric radiology based on the third quartile value of the skin entrance doses have been recommended and are compared with guidance levels. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine

  9. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  10. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  11. Patient and population doses of x-ray diagnostics in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Rannikko, S; Karila, K T.K.; Toivonen, M

    1997-09-01

    Periodic surveys of patient and population doses are important because of the large contribution of x-ray diagnostics to the artificial population dose. Measured entrance surface doses and dose-area products are the main quantities used for monitoring patient doses in hospitals, and most population dose studies have been derived from these quantities and from the frequences of x-ray examinations. This study is based on the radiation, exposure geometry, and patient parameters recorded by experienced radiographers and postgraduated students. The software used in the work (ODS-60 of Rados Technology) suits the determination of effective and organ doses from such detailed data using a human-like patient phantom which can be adapted for sex and size. The program, together with the very detailed input data, made it possible to determine organ equivalent and effective doses for complicated dynamic x-ray examinations and interventions in more detail than in previous studies. Collective organ and effective doses were derived for 50 examination types. The annual collective dose from diagnostic x-ray examinations in 1994 was 0.5 mSv per capita in Finland. The five groups of examinations or examinations that had greatest contributions to the collective dose were CT, barium enema: double contrast, lumbar spine, carotid angiography, and intestinal transit. Together they represented for about 60 % of the total dose. The highest dose-area products (about 2000 Gy cm{sup 2}) were obtained from certain angiographic and interventional examinations. A literature survey showed that Finland patient doses are at the same average level as in other countries of a high standard of health care. (orig.). 125 refs.

  12. Patient and population doses of x-ray diagnostics in Finland

    International Nuclear Information System (INIS)

    Rannikko, S.; Karila, K.T.K.; Toivonen, M.

    1997-09-01

    Periodic surveys of patient and population doses are important because of the large contribution of x-ray diagnostics to the artificial population dose. Measured entrance surface doses and dose-area products are the main quantities used for monitoring patient doses in hospitals, and most population dose studies have been derived from these quantities and from the frequences of x-ray examinations. This study is based on the radiation, exposure geometry, and patient parameters recorded by experienced radiographers and postgraduated students. The software used in the work (ODS-60 of Rados Technology) suits the determination of effective and organ doses from such detailed data using a human-like patient phantom which can be adapted for sex and size. The program, together with the very detailed input data, made it possible to determine organ equivalent and effective doses for complicated dynamic x-ray examinations and interventions in more detail than in previous studies. Collective organ and effective doses were derived for 50 examination types. The annual collective dose from diagnostic x-ray examinations in 1994 was 0.5 mSv per capita in Finland. The five groups of examinations or examinations that had greatest contributions to the collective dose were CT, barium enema: double contrast, lumbar spine, carotid angiography, and intestinal transit. Together they represented for about 60 % of the total dose. The highest dose-area products (about 2000 Gy cm 2 ) were obtained from certain angiographic and interventional examinations. A literature survey showed that Finland patient doses are at the same average level as in other countries of a high standard of health care. (orig.)

  13. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  14. Dose-to-dose variations with single packages of counterfeit medicines and adulterated dietary supplements as a potential source of false negatives and inaccurate health risk assessments.

    Science.gov (United States)

    Venhuis, B J; Zwaagstra, M E; Keizers, P H J; de Kaste, D

    2014-02-01

    In this report, we show three examples of how the variability in dose units in single packages of counterfeit medicines and adulterated dietary supplements may contribute to a false negative screening result and inaccurate health risk assessments. We describe a counterfeit Viagra 100mg blister pack and a box of an instant coffee both containing dose units with and without an active pharmaceutical ingredient (API). We also describe a purportedly herbal slimming product with capsules that mutually differed in API and impurities. The adulterated dietary supplements contained sibutramine, benzyl-sibutramine, N-desmethyl-sibutramine (DMS), N,N-didesmethyl-sibutramine (DDMS) and several other related impurities. Counterfeit medicines and adulterated dietary supplements are a health risk because their quality is unreliable. Health risks are even greater when such unreliability extends to fundamental differences between dose units in one package. Because dose-to-dose variability for these products is unpredictable, the confidence interval of a sample size is unknown. Consequently, the analyses of a selection of dose units may not be representative for the package. In the worst case, counterfeit or unauthorised medicines are not recognised as such or a health risk is not identified. In order to reduce erroneous results particular care should be taken when analysing a composite of dose units, when finding no API in a dietary supplement and when finding conformity in a suspect counterfeit medicine. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Low doses of ionizing radiation: Biological effects and regulatory control. Contributed papers

    International Nuclear Information System (INIS)

    1997-11-01

    The International Atomic Energy Agency and the World Health Organization, in cooperation with the United Nations Scientific Committee on the Effects of Atomic Radiation, organized an international conference on Low Doses of Ionizing Radiation: Biological Effects and Regulatory Control, held in seville, Spain, from 17 to 21 November 1997. This technical document contains concise papers submitted to the conference

  16. On uncertainties in definition of dose equivalent

    International Nuclear Information System (INIS)

    Oda, Keiji

    1995-01-01

    The author has entertained always the doubt that in a neutron field, if the measured value of the absorbed dose with a tissue equivalent ionization chamber is 1.02±0.01 mGy, may the dose equivalent be taken as 10.2±0.1 mSv. Should it be 10.2 or 11, but the author considers it is 10 or 20. Even if effort is exerted for the precision measurement of absorbed dose, if the coefficient being multiplied to it is not precise, it is meaningless. [Absorbed dose] x [Radiation quality fctor] = [Dose equivalent] seems peculiar. How accurately can dose equivalent be evaluated ? The descriptions related to uncertainties in the publications of ICRU and ICRP are introduced, which are related to radiation quality factor, the accuracy of measuring dose equivalent and so on. Dose equivalent shows the criterion for the degree of risk, or it is considered only as a controlling quantity. The description in the ICRU report 1973 related to dose equivalent and its unit is cited. It was concluded that dose equivalent can be considered only as the absorbed dose being multiplied by a dimensionless factor. The author presented the questions. (K.I.)

  17. Job-related doses in light water reactors

    International Nuclear Information System (INIS)

    Schnuer, K.

    1993-01-01

    The Treaty of 1957 establishing the European Atomic Energy Community, (EURATOM) was an essential prerequisite for the development of a strong nuclear industry in Europe. Among other things the Treaty provides that the Community shall lay down Basic Safety Standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiation and ensure that they are applied. Following adoption of the Council Directive of 1980, the European Commission defined the basic principles of Justification, Optimization and Limitation to be applied in order to ensure the greatest possible protection of workers and the general public. Subsequently the Commission took initiatives in order to find ways of implementing these three basic principles in practical radiation protection. In 1980 the Commission in close collaboration with the leading nuclear power station operators, set up its own system of 'occupational radiation dose statistics from light water reactors operating in Western Europe'. This was designed for PWRs and BWRs, and the Commission benefited from the experience of neighbouring non-EC countries such as Sweden, Finland, Switzerland and Spain (not yet a member) operating nuclear power stations made by different manufacturers. The paper provides some general information on developments and trends in collective and individual doses to workers in nuclear power stations, based on a unique European databank of approximately 1000 operating reactor years. 9 figs

  18. Estimation of 210Po activity in mussel sample and its contribution in radiation dose to the public around Kanyakumari Coast, India

    International Nuclear Information System (INIS)

    Macklin Rani, L.; Govindaraju, M.; Jeevanram, R.K.; Muthukumaran, V.R.

    2013-01-01

    Polonium-210 ( 210 Po), a naturally occurring á-emitting radionuclide exists in the environment as a result of Uranium- 238 ( 238 U) decay chain. It is therefore ubiquitously distributed in the rocks, soils, making up Earths crust, in the atmosphere and in natural waters. 210 Po enters in marine organisms via adsorption, absorption and ingestion and is transferred through seafood consumption. The concentration of 210 Po in the edible portions of marine organisms may be many folds higher than that in the seawater because of biological re-concentration processes. In the present study, sampling sites were chosen to determine the difference of 210 Po concentration in bivalve mussel, an appropriate bio-indicator for radioactive contamination. The concentration of radionuclide Polonium-210 ( 210 Po) in brown mussel (Perna perna), obtained from different locations of Kanyakumari coastal area were estimated, which ranged between 76.0 ± 5.1 Bq/kg and 310.20 ± 18.4 Bq/kg. The highest activity was observed at Kalluvilai. The daily and annual intake of 210 Po from ingestion via mussel was estimated in these areas. To evaluate the internal exposure, annual committed effective dose to the adult population of this coastal area was determined and compared with the Indian and worldwide values to assess the risk status of the study area. It was observed that the average annual committed effective dose of 210 Po through ingestion is higher than the recommended dose of ICRP, 1990 (1 mSv/year) for general public due to the contribution of seafood, mussel species (3.09 mSv/year) in daily diet. (author)

  19. Reassessment of calculation of effective dose equivalent for the CRCN-CO Environmental Radiological Monitoring Program

    International Nuclear Information System (INIS)

    Carneiro, L.B.; Dourado, M.A.; Barbosa, R.C.

    2017-01-01

    To reassess the calculations of the effective dose equivalent to obtain data of dosimetry and the accomplishment of the analysis comparing the data of several techniques that record doses of radiation originating from the cosmogenic and terrestrial contributions that make up the so-called background radiation. the basic information to be obtained is the contribution of the difference between the terrestrial dose equivalents, even the lowest concentration of primordial radionuclides, and that of the dose equivalent, deduced from TLD readings. (author)

  20. Reassessment of calculation of effective dose equivalent for the CRCN-CO Environmental Radiological Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, L.B.; Dourado, M.A.; Barbosa, R.C., E-mail: research.photonics@gmail.com [Centro Regional de Ciências Nucleares do Centro-Oeste (CRCN-CO/CNEN-GO), Abadia de Goiás, GO (Brazil)

    2017-07-01

    To reassess the calculations of the effective dose equivalent to obtain data of dosimetry and the accomplishment of the analysis comparing the data of several techniques that record doses of radiation originating from the cosmogenic and terrestrial contributions that make up the so-called background radiation. the basic information to be obtained is the contribution of the difference between the terrestrial dose equivalents, even the lowest concentration of primordial radionuclides, and that of the dose equivalent, deduced from TLD readings. (author)

  1. Trends in doses to radiation workers recorded on the Central Index of Dose Information

    International Nuclear Information System (INIS)

    Greenslade, E.; Kendall, G.M.; Fillary, K.; Bines, W.P.

    1991-01-01

    This paper presents a preliminary analysis of the doses stored on the Central Index of Dose Information for the calendar years 1986, 1987 and 1988. Mean doses are low, and both mean doses and the proportion of workers exceeding 15 mSv in a year are decreasing with time. Underground miners are the occupational group receiving the highest doses, though in this and other relatively high dose groups the exposures are falling with time. Only 6% of workers are female and their average individual dose is about half that of men. Patterns of employment are different for women and men but there is a tendency for women to receive lower doses than men even within the same occupation. (author)

  2. Updated radiological dose assessment of Bikini and Eneu Islands at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Stuart, M.L.; Thompson, S.E.; Conrado, C.L.; Stoker, A.C.

    1982-01-01

    This report is part of a continuing effort to refine dose assessments for resettlement options at Bikini Atoll. Radionuclide concentration data developed at Bikini Atoll since 1977 have been used in conjunction with recent dietary information and current dose models to develop the annual dose rate and 30- and 50-y integral doses presented here for Bikini and Eneu Island living patterns. The terrestrial food chain is the most significant exposure pathway--it contributes more than 50% of the total dose--and external gamma exposure is the second most significant pathway. Other pathways evaluated are the marine food chain, drinking water, and inhalation. Cesium-137 produces more than 85% of the predicted dose; 90 Sr is the second most significant radionuclide; 60 Co contributes to the external gamma exposure in varying degrees, but is a small part of the total predicted dose; the transuranic radionuclides contribute a small portion of the total predicted lung and bone doses but do present a long-term source of exposure. Maximum annual dose rates for Bikini Island are about 1 rem/y for the whole body and bone marrow when imported foods are available and about 1.9 rem/y when imports are unavailable. Maximum annual dose rates for Eneu Island when imports are available are 130 mrem/y for the whole body and 136 mrem/y for bone marrow. Similar doses when imported foods are unavailable are 245 and 263 mrem/y, respectively. The 30-y integral doses for Bikini Island are about 23 rem for whole body and bone marrow when imported foods are available and more than 40 rem when imports are unavailable. The Eneu Island 30-y integral doses for whole body and bone marrow are about 3 rem when imports are available and 5.5 and 6.1 rem, respectively, when imports are unavailable. Doses from living patterns involving some combination of Bikini and Eneu Islands fall between the doses listed above for each island separately

  3. Use of the Concept of Equivalent Biologically Effective Dose (BED) to Quantify the Contribution of Hyperthermia to Local Tumor Control in Radiohyperthermia Cervical Cancer Trials, and Comparison With Radiochemotherapy Results

    International Nuclear Information System (INIS)

    Plataniotis, George A.; Dale, Roger G.

    2009-01-01

    Purpose: To express the magnitude of contribution of hyperthermia to local tumor control in radiohyperthermia (RT/HT) cervical cancer trials, in terms of the radiation-equivalent biologically effective dose (BED) and to explore the potential of the combined modalities in the treatment of this neoplasm. Materials and Methods: Local control rates of both arms of each study (RT vs. RT+HT) reported from randomized controlled trials (RCT) on concurrent RT/HT for cervical cancer were reviewed. By comparing the two tumor control probabilities (TCPs) from each study, we calculated the HT-related log cell-kill and then expressed it in terms of the number of 2 Gy fraction equivalents, for a range of tumor volumes and radiosensitivities. We have compared the contribution of each modality and made some exploratory calculations on the TCPs that might be expected from a combined trimodality treatment (RT+CT+HT). Results: The HT-equivalent number of 2-Gy fractions ranges from 0.6 to 4.8 depending on radiosensitivity. Opportunities for clinically detectable improvement by the addition of HT are only available in tumors with an alpha value in the approximate range of 0.22-0.28 Gy -1 . A combined treatment (RT+CT+HT) is not expected to improve prognosis in radioresistant tumors. Conclusion: The most significant improvements in TCP, which may result from the combination of RT/CT/HT for locally advanced cervical carcinomas, are likely to be limited only to those patients with tumors of relatively low-intermediate radiosensitivity.

  4. An updated dose assessment for a U.S. Nuclear Test Site - Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1995-10-01

    On March 1, 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1975. The unique composition of coral soil greatly alters the relative contribution of cesium-137 ( 137 Cs) and strontium-90 ( 90 Sr) to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, cesium-137 produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The corresponding 30-, 50-, and 70-y integral effective doses are 9.1 cSv, 13 cSv, and 15 cSv, respectively. A corresponding uncertainty analysis showed that after about 5 y of residence, the 95% confidence limits on population-average dose would be ±35% of its expected value. We have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to about 5% of pretreatment levels and has essentially no negative environmental consequences

  5. Dose Assessment Model for Chronic Atmospheric Releases of Tritium

    International Nuclear Information System (INIS)

    Shen Huifang; Yao Rentai

    2010-01-01

    An improved dose assessment model for chronic atmospheric releases of tritium was proposed. The proposed model explicitly considered two chemical forms of tritium.It was based on conservative assumption of transfer of tritiated water (HTO) from air to concentration of HTO and organic beam tritium (OBT) in vegetable and animal products.The concentration of tritium in plant products was calculated based on considering dividedly leafy plant and not leafy plant, meanwhile the concentration contribution of tritium in the different plants from the tritium in soil was taken into account.Calculating the concentration of HTO in animal products, average water fraction of animal products and the average weighted tritium concentration of ingested water based on the fraction of water supplied by each source were considered,including skin absorption, inhalation, drinking water and food.Calculating the annual doses, the ingestion doses were considered, at the same time the contribution of inhalation and skin absorption to the dose was considered. Concentrations in foodstuffs and dose of annual adult calculated with the specific activity model, NEWTRI model and the model proposed by the paper were compared. The results indicate that the model proposed by the paper can predict accurately tritium doses through the food chain from chronic atmospheric releases. (authors)

  6. An updated dose assessment for Rongelap Island

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W.L.; Conrado, C.L.; Bogen, K.T.

    1994-07-01

    We have updated the radiological dose assessment for Rongelap Island at Rongelap Atoll using data generated from field trips to the atoll during 1986 through 1993. The data base used for this dose assessment is ten fold greater than that available for the 1982 assessment. Details of each data base are presented along with details about the methods used to calculate the dose from each exposure pathway. The doses are calculated for a resettlement date of January 1, 1995. The maximum annual effective dose is 0.26 mSv y{sup {minus}1} (26 mrem y{sup {minus}1}). The estimated 30-, 50-, and 70-y integral effective doses are 0.0059 Sv (0.59 rem), 0.0082 Sv (0.82 rem), and 0.0097 Sv (0.97 rem), respectively. More than 95% of these estimated doses are due to 137-Cesium ({sup 137}Cs). About 1.5% of the estimated dose is contributed by 90-Strontium ({sup 90}Sr), and about the same amount each by 239+240-Plutonium ({sup 239+240}PU), and 241-Americium ({sup 241}Am).

  7. The relative contributions of social cognition and self-reflectiveness to clinical insight in enduring schizophrenia.

    Science.gov (United States)

    Béland, Sophie; Lepage, Martin

    2017-12-01

    Poor clinical insight represents a major barrier to recovery in schizophrenia. Research suggests that higher-order social cognitive abilities such as theory of mind (TOM) and metacognition contribute to levels of clinical insight. However, few studies have examined whether social cognitive abilities other than TOM are related to clinical insight. Moreover, to date, no investigation has attempted to determine whether the contribution of metacognitive ability to clinical insight can be differentiated from the contribution of higher-order social cognition, despite their conceptual similarity. Therefore, the purpose of this study was to examine the relative contribution of different social cognitive abilities, as well as metacognition, to clinical insight in a large sample of 139 enduring schizophrenia patients, and controlling for established predictors of clinical insight. Hierarchical regression analyses were used to evaluate the portion of variance explained by 3 social cognitive abilities: emotion recognition, TOM, and affective empathy, and the metacognitive ability of self-reflectiveness. Clinical insight levels were assessed using the Schedule for the Assessment of Insight-Expanded version. Results indicated that affective empathy and self-reflectiveness are the strongest predictors of clinical insight. These results provide insights on the development of targeted interventions for improving clinical insight in this population. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Dermal exposure to jet fuel JP-8 significantly contributes to the production of urinary naphthols in fuel-cell maintenance workers.

    Science.gov (United States)

    Chao, Yi-Chun E; Kupper, Lawrence L; Serdar, Berrin; Egeghy, Peter P; Rappaport, Stephen M; Nylander-French, Leena A

    2006-02-01

    Jet propulsion fuel 8 (JP-8) is the major jet fuel used worldwide and has been recognized as a major source of chemical exposure, both inhalation and dermal, for fuel-cell maintenance workers. We investigated the contributions of dermal and inhalation exposure to JP-8 to the total body dose of U.S. Air Force fuel-cell maintenance workers using naphthalene as a surrogate for JP-8 exposure. Dermal, breathing zone, and exhaled breath measurements of naphthalene were obtained using tape-strip sampling, passive monitoring, and glass bulbs, respectively. Levels of urinary 1- and 2-naphthols were determined in urine samples and used as biomarkers of JP-8 exposure. Multiple linear regression analyses were conducted to investigate the relative contributions of dermal and inhalation exposure to JP-8, and demographic and work-related covariates, to the levels of urinary naphthols. Our results show that both inhalation exposure and smoking significantly contributed to urinary 1-naphthol levels. The contribution of dermal exposure was significantly associated with levels of urinary 2-naphthol but not with urinary 1-naphthol among fuel-cell maintenance workers who wore supplied-air respirators. We conclude that dermal exposure to JP-8 significantly contributes to the systemic dose and affects the levels of urinary naphthalene metabolites. Future work on dermal xenobiotic metabolism and toxicokinetic studies are warranted in order to gain additional knowledge on naphthalene metabolism in the skin and the contribution to systemic exposure.

  9. Long-term changes of renal function in relation to ace inhibitor/angiotensin receptor blocker dosing in patients with heart failure and chronic kidney disease.

    Science.gov (United States)

    Fröhlich, Hanna; Nelges, Christoph; Täger, Tobias; Schwenger, Vedat; Cebola, Rita; Schnorbach, Johannes; Goode, Kevin M; Kazmi, Syed; Katus, Hugo A; Cleland, John G F; Clark, Andrew L; Frankenstein, Lutz

    2016-08-01

    Angiotensin-converting enzyme inhibitors (ACEIs) and angiotensin receptor blockers (ARBs) have become cornerstones of therapy for chronic heart failure (CHF). Guidelines advise high target doses for ACEIs/ARBs, but fear of worsening renal function may limit dose titration in patients with concomitant chronic kidney disease (CKD). In this retrospective observational study, we identified 722 consecutive patients with systolic CHF, stable CKD stage III/IV (estimated glomerular filtration rate [eGFR] 15-60 mL min(-1) 1.73 m(-2)) and chronic ACEI/ARB treatment from the outpatient heart failure clinics at the Universities of Hull, UK, and Heidelberg, Germany. Change of renal function, worsening CHF, and hyperkalemia at 12-month follow-up were analyzed as a function of both baseline ACEI/ARB dose and dose change from baseline. ΔeGFR was not related to baseline dose of ACEI/ARB (P = .58), or to relative (P = .18) or absolute change of ACEI/ARB dose (P = .21) during follow-up. Expressing change of renal function as a categorical variable (improved/stable/decreased) as well as subgroup analyses with respect to age, sex, New York Heart Association functional class, left ventricular ejection fraction, diabetes, concomitant aldosterone antagonists, CKD stage, hypertension, ACEI vs ARB, and congestion status yielded similar results. There was no association of dose/dose change with incidence of either worsening CHF or hyperkalemia. In patients with systolic CHF and stable CKD stage III/IV, neither continuation of high doses of ACEI/ARB nor up-titration was related to adverse changes in longer-term renal function. Conversely, down-titration was not associated with improvement in eGFR. Use of high doses of ACEI/ARB and their up-titration in patients with CHF and CKD III/IV may be appropriate provided that the patient is adequately monitored. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Low doses of ionizing radiation: Biological effects and regulatory control. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    The International Atomic Energy Agency and the World Health Organization, in cooperation with the United Nations Scientific Committee on the Effects of Atomic Radiation, organized an international conference on Low Doses of Ionizing Radiation: Biological Effects and Regulatory Control, held in seville, Spain, from 17 to 21 November 1997. This technical document contains concise papers submitted to the conference. Refs, figs, tabs.

  11. A survey of chest medical X-ray doses

    International Nuclear Information System (INIS)

    Lomba, M.; Conha, P.G. da; Almeida, C.E. de

    1996-01-01

    The medical X-ray exposures due to radiological examinations are responsible for the largest contribution to the population collective dose as result of the normal use of artificial sources of radiation. The relative impact of the medical exposures to the total dose received by the population from all kinds of radiation sources varies from country to country and in some cases within the same country. The dose variations observed for a specific type of examination are in general associated to several factors i.e. the type of film-ecran combination, the choice of the appropriate physical parameters of the X-ray generator (Kvp, filament current, exposure time) and finally to the film processing conditions. At the present moment the data available in Brazil are scarce and scanty to allow a complete analyzis of this question so needed by the health authorities to justify the implementation of a quality assurance and dose reduction programs. In addition, it is desirable to establish a cost effective operation based on simple administrative concepts in order to reduce the number of films retake, then increasing the life expectancy of the equipment and the number of radiological procedures. The aim of this work was to assess the typical doses of an PA and LAT chest wall X-ray examinations in five different public hospitals (a University Hospital, a Cancer Hospital, a Navy Hospital, an Emergency Hospital and a State General Hospital), as representative of the city of Rio de Janeiro, and compare the results with the international data and recommendations available. (author)

  12. Reduced-Nicotine Cigarettes in Young Smokers: Impact of Nicotine Metabolism on Nicotine Dose Effects.

    Science.gov (United States)

    Faulkner, Paul; Ghahremani, Dara G; Tyndale, Rachel F; Cox, Chelsea M; Kazanjian, Ari S; Paterson, Neil; Lotfipour, Shahrdad; Hellemann, Gerhard S; Petersen, Nicole; Vigil, Celia; London, Edythe D

    2017-07-01

    The use of cigarettes delivering different nicotine doses allows evaluation of the contribution of nicotine to the smoking experience. We compared responses of 46 young adult smokers to research cigarettes, delivering 0.027, 0.110, 0.231, or 0.763 mg nicotine, and conventional cigarettes. On five separate days, craving, withdrawal, affect, and sustained attention were measured after overnight abstinence and again after smoking. Participants also rated each cigarette, and the nicotine metabolite ratio (NMR) was used to identify participants as normal or slow metabolizers. All cigarettes equally alleviated craving, withdrawal, and negative affect in the whole sample, but normal metabolizers reported greater reductions of craving and withdrawal than slow metabolizers, with dose-dependent effects. Only conventional cigarettes and, to a lesser degree, 0.763-mg nicotine research cigarettes increased sustained attention. Finally, there were no differences between ratings of lower-dose cigarettes, but the 0.763-mg cigarettes and (even more so) conventional cigarettes were rated more favorably than lower-dose cigarettes. The findings indicate that smoking-induced relief of craving and withdrawal reflects primarily non-nicotine effects in slow metabolizers, but depends on nicotine dose in normal metabolizers. By contrast, relief of withdrawal-related attentional deficits and cigarette ratings depend on nicotine dose regardless of metabolizer status. These findings have bearing on the use of reduced-nicotine cigarettes to facilitate smoking cessation and on policy regarding regulation of nicotine content in cigarettes. They suggest that normal and slow nicotine metabolizers would respond differently to nicotine reduction in cigarettes, but that irrespective of metabolizer status, reductions to <0.763 mg/cigarette may contribute to temporary attentional deficits.

  13. The importance of dose, frequency and duration of vitamin D supplementation for plasma 25-hydroxyvitamin D.

    Science.gov (United States)

    Chao, Yi-Sheng; Brunel, Ludovic; Faris, Peter; Veugelers, Paul J

    2013-10-11

    The importance of dose, frequency and duration of vitamin D supplementation for plasma 25(OH)D levels is not well described and rarely reported for supplementation that exceeds 2000 IU per day. The objective is to examine dose, frequency and duration of supplementation in relation to plasma 25(OH)D in a large population-based sample. We accessed data on 2714 volunteers that contributed to 4224 visits and applied multilevel regression. Compared to not using supplements, a minimum regimen of 1000-2000 IU once or twice per week for one month was not effective in raising 25(OH)D. Compared to this minimum regimen, higher doses of 2000-3000, 3000-4000, and 5000 IU or more were associated with a 7.49, 13.19 and 30.22 nmol/L 25(OH)D increase, respectively; frequencies of three to four, five to six and seven times/week were associated with a 5.44, 16.52 and 30.69 nmol/L increase, respectively; and supplementation of five months or longer was associated with an increase of 6.68 nmol/L (p D. Whereas dose, frequency and duration of supplementation are important to healthy subjects committed to optimizing their nutritional status, to the design of clinical trials, individual characteristics and lifestyle contribute substantially to 25(OH)D.

  14. Airborne contamination in the indoor environment and its implications for dose

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, K.G.; Roed, J.; Byrne, M.A.; Hession, H.; Clark, P.; Elahi, E.; Buskov, A.; Hou, X.L.; Prip, H.; Olsen, S.K.; Roed, T

    2004-04-01

    Previous work has indicated that radiation doses from deposition on human skin, hair and clothing may contribute significantly to the dose received after a major nuclear accident, such as that, which happened at Chernobyl in 1986. The available data was, however, sparse and associated with considerable variation, clearly showing a need for further investigations to verify preliminary conclusions, examine processes in greater detail and identify important factors causing the observed parameter variation. For instance, the impacts of thermophoresis, electrophoresis, skin moisture and wind speed on the deposition of contaminant aerosol were examined, and since the previous measurements had indicated that elemental iodine could be a particularly problematic contaminant, experimental work was additionally undertaken to examine the process of deposition of this species to skin. Since both clearance and percutaneous penetration of deposited contaminants could play important roles in determining doses, experimental programmes were dedicated to the identification of parameters of interest in these contexts. Also doses from contamination on different surfaces in the indoor environment have in the past traditionally been neglected, and a theoretical approach, based on measurements, was developed for accurate prediction of these doses under different conditions. Also resuspension of deposited matter and its role in dose formation, by subsequent deposition or inhalation, was investigated through experiments. Contact transfer of contaminants from an indoor surface to human skin may give yet another contribution to dose and also the relevant parameters in this direction were examined experimentally. The ultimate goal of the investigations was to enable the determination of the various contributions to dose in a contaminated indoor environment. A model methodology was developed and an example of its use was given. It was found that after a major nuclear accident, doses from indoor

  15. Airborne contamination in the indoor environment and its implications for dose

    DEFF Research Database (Denmark)

    Andersson, Kasper Grann; Roed, Jørn; Byrne, M.A.

    2004-01-01

    Previous work has indicated that radiation doses from deposition on human skin, hair and clothing may contribute significantly to the dose received after a major nuclear accident, such as that, which happened at Chernobyl in 1986. The available data was,however, sparse and associated with conside......Previous work has indicated that radiation doses from deposition on human skin, hair and clothing may contribute significantly to the dose received after a major nuclear accident, such as that, which happened at Chernobyl in 1986. The available data was,however, sparse and associated...... on the deposition of contaminant aerosol were examined, and since the previous measurements had indicated that elemental iodine could be a particularly problematiccontaminant, experimental work was additionally undertaken to examine the process of deposition of this species to skin. Since both clearance...... and percutaneous penetration of deposited contaminants could play important roles in determining doses,experimental programmes were dedicated to the identification of parameters of interest in these contexts. Also doses from contamination on different surfaces in the indoor environment have in the past...

  16. Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

    Science.gov (United States)

    Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H

    2015-01-01

    To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.

  17. A trial of radiation dose prescription based on dose-cell survival formula

    International Nuclear Information System (INIS)

    Allen, E.P.

    1984-01-01

    Radiation treatment has been prescribed for 379 basal cell carcinomata on the basis of a selected equivalent single dose derived from the standard multi-target dose-cell survival formula using values of m = 2 and Do = 130 rads for orthovoltage x-rays. The results suggest that the approach provides a flexible and acceptable alternative to prescription by total dose or by Nominal Standard Dose. It is submitted that Total Dose is an inadequate expression of radiobiological effects: that the NSD and related systems are valuable measures of the ability of normal tissues to recover from radiation damage: and that a parallel measure of the degree of tumour depopulation has become necessary to allow further progress in alternative fractionation schedules

  18. Contributions to the genetic and mean bone-marrow doses of the Australian population from radiological procedures

    International Nuclear Information System (INIS)

    Swindon, T.N.; Morris, N.D.

    1980-06-01

    The results of a national survey of radiological procedures used for diagnosis and therapy in medicine, dentistry and chiropracty are reviewed. Statistical data for the distribution and frequency of various procedures in Australian hospitals and practices are summarised, together with their associated radiation doses. Annual genetically significant and mean bone-marrow doses to the Australian population arising from these procedures are derived for the survey year of 1970. Values of 176 microgray and 651 microgray for the annual (per capita) genetic and mean bone-marrow doses respectively are reported. These compare closely with corresponding estimates in other countries with similar medical practices to those in Australia

  19. Bladder accumulated dose in image-guided high-dose-rate brachytherapy for locally advanced cervical cancer and its relation to urinary toxicity

    Science.gov (United States)

    Zakariaee, Roja; Hamarneh, Ghassan; Brown, Colin J.; Gaudet, Marc; Aquino-Parsons, Christina; Spadinger, Ingrid

    2016-12-01

    The purpose of this study was to estimate locally accumulated dose to the bladder in multi-fraction high-dose-date (HDR) image-guided intracavitary brachytherapy (IG-ICBT) for cervical cancer, and study the locally-accumulated dose parameters as predictors of late urinary toxicity. A retrospective study of 60 cervical cancer patients who received five HDR IG-ICBT sessions was performed. The bladder outer and inner surfaces were segmented for all sessions and a bladder-wall contour point-set was created in MATLAB. The bladder-wall point-sets for each patient were registered using a deformable point-set registration toolbox called coherent point drift (CPD), and the fraction doses were accumulated. Various dosimetric and volumetric parameters were calculated using the registered doses, including r{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} (minimum dose to the most exposed n-cm3 volume of bladder wall), r V n Gy (wall volume receiving at least m Gy), and r\\text{EQD}{{2}n \\text{c{{\\text{m}}\\text{3}}}} (minimum equivalent biologically weighted dose to the most exposed n-cm3 of bladder wall), where n  =  1/2/5/10 and m  =  3/5/10. Minimum dose to contiguous 1 and 2 cm3 hot-spot volumes was also calculated. The unregistered dose volume histogram (DVH)-summed equivalent of r{{\\text{D}}n \\text{c{{\\text{m}}3}}} and r\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} parameters (i.e. s{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} and s\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} ) were determined for comparison. Late urinary toxicity was assessed using the LENT-SOMA scale, with toxicity Grade 0-1 categorized as Controls and Grade 2-4 as Cases. A two-sample t-test was used to identify the differences between the means of Control and Case groups for all parameters. A binomial logistic regression was also performed between the registered dose parameters and toxicity grouping. Seventeen patients were in the Case and 43 patients in the Control group. Contiguous

  20. Variations of 210Po and 210Pb in various marine organisms from Western English Channel: contribution of 210Po to the radiation dose

    International Nuclear Information System (INIS)

    Connan, O.; Germain, P.; Solier, L.; Gouret, G.

    2007-01-01

    Measurements of 210 Po were carried out in various marine matrices (mussels, oysters, seaweed, fish, and abalones) and in seawater at several points along the French coast, over a period of 2 years (2003-2005). These measurements contribute to a better knowledge of this element, since few recent data exist for the French coast. Marked seasonal variations have been revealed in some species and there are differences according to the way of life of these species. Activities in mussels (Mytilus edulis) and oysters (Crassostrea gigas) are similar and varying between 90 and 600 Bq kg -1 (d.w.). Activities in macroalgae (Fucus serratus) are lowest, between 4 and 16 Bq kg -1 (d.w.). In oyster, abalone (Haliotis tuberculata) and fish (Solea solea, Sparus sp.), the strongest activities are measured in the digestive glands, the gills and the gonads. 210 Po/ 210 Pb ratios in all cases have values of more than one for all species. From a significant number of measurements, CFs were calculated for seaweed (between 4.6 x 10 3 and 5.0 x 10 3 ) and for molluscs, with highest CFs (>10 5 ) found for the digestive gland and gills of the oysters, the digestive gland of the abalones and the liver of fish. Finally, the activities measured have made it possible to estimate the internal dose from chronic exposure due to 210 Po received by the marine organisms (0.05 μG h -1 for macroalgae, between 0.70 and 1.5 μG h -1 for mussels and oyster), and the contribution of seafood to the dose received by humans (46-129 μSv y -1 )

  1. Dosimetry studies with 32P source and correlation of skin and eye lens doses

    International Nuclear Information System (INIS)

    Kumar, Munish; Gaonkar, U.P.; Koul, D.K.; Datta, D.; Saxena, S.K.; Kumar, Yogendra; Dash, A.

    2018-01-01

    Beta particles are one of the major contributors toward skin and eye lens doses at facilities handling beta sources. These sources find applications in industry, pharmaceuticals as well as in brachytherapy applications. The beta particles having maximum (E max ) energy > 0.07 MeV are capable of delivering skin dose whereas beta particles having maximum (E max ) energy > 0.7 MeV may also contribute towards dose to eye lens. Studies are performed using 32 P beta source as its maximum beta energy (E max ) is such that for sources having (E max ) of 1.71 MeV or beyond, there can be substantial contribution towards dose to eye lens even the dose limit recommended for skin is followed

  2. The relative biological effectiveness of fractionated doses of fast neutrons (42 MeVd→Be) for normal tissues. Pt. 3

    International Nuclear Information System (INIS)

    Rezvani, M.; Hopewell, J.W.; Robbins, M.E.C.; Hamlet, R.; Barnes, D.W.H.; Sansom, J.M.; Adams, P.J.V.

    1990-01-01

    The effect of single and fractionated doses of fast neutrons (42 MeV d→Bc ) on the early and late radiation responses of the pig lung have been assessed by the measurement of changes in lung function using a 133 Xe washout technique. The results obtained for irradiation schedules with fast neutrons have been compared with those after photon irradiation. There was no statistically significant difference between the values for the relative biological effectiveness (RBE) for the early and late radiation response of the lung. The RBE of the neutron beam increased with decreasing size of dose/fraction with an upper limit value of 4.39 ± 0.94 for infinitely small X-ray doses per fraction. (author)

  3. Estimated collective effective dose to the population from nuclear medicine examinations in Slovenia

    International Nuclear Information System (INIS)

    Skrk, Damijan; Zontar, Dejan

    2013-01-01

    A national survey of patient exposure from nuclear medicine diagnostic procedures was performed by Slovenian Radiation Protection Administration in order to estimate their contribution to the collective effective dose to the population of Slovenia. A set of 36 examinations with the highest contributions to the collective effective dose was identified. Data about frequencies and average administered activities of radioisotopes used for those examinations were collected from all nuclear medicine departments in Slovenia. A collective effective dose to the population and an effective dose per capita were estimated from the collected data using dose conversion factors. The total collective effective dose to the population from nuclear medicine diagnostic procedures in 2011 was estimated to 102 manSv, giving an effective dose per capita of 0.05 mSv. The comparison of results of this study with studies performed in other countries indicates that the nuclear medicine providers in Slovenia are well aware of the importance of patient protection measures and of optimisation of procedures

  4. Time- and dose rate-related effects of internal 177Lu exposure on gene expression in mouse kidney tissue

    International Nuclear Information System (INIS)

    Schüler, Emil; Rudqvist, Nils; Parris, Toshima Z.; Langen, Britta; Spetz, Johan; Helou, Khalil; Forssell-Aronsson, Eva

    2014-01-01

    Introduction: The kidneys are the dose-limiting organs in some radionuclide therapy regimens. However, the biological impact of internal exposure from radionuclides is still not fully understood. The aim of this study was to examine the effects of dose rate and time after i.v. injection of 177 LuCl 3 on changes in transcriptional patterns in mouse kidney tissue. Methods: To investigate the effect of dose rate, female Balb/c nude mice were i.v. injected with 11, 5.6, 1.6, 0.8, 0.30, and 0 MBq of 177 LuCl 3 , and killed at 3, 6, 24, 48, 168, and 24 hours after injection, respectively. Furthermore, the effect of time after onset of exposure was analysed using mice injected with 0.26, 2.4, and 8.2 MBq of 177 LuCl 3 , and killed at 45, 90, and 140 days after injection. Global transcription patterns of irradiated kidney cortex and medulla were assessed and enriched biological processes were determined from the regulated gene sets using Gene Ontology terms. Results: The average dose rates investigated were 1.6, 0.84, 0.23, 0.11 and 0.028 mGy/min, with an absorbed dose of 0.3 Gy. At 45, 90 and 140 days, the absorbed doses were estimated to 0.3, 3, and 10 Gy. In general, the number of differentially regulated transcripts increased with time after injection, and decreased with absorbed dose for both kidney cortex and medulla. Differentially regulated transcripts were predominantly involved in metabolic and stress response-related processes dependent on dose rate, as well as transcripts associated with metabolic and cellular integrity at later time points. Conclusion: The observed transcriptional response in kidney tissue was diverse due to difference in absorbed dose, dose rate and time after exposure. Nevertheless, several transcripts were significantly regulated in all groups despite differences in exposure parameters, which may indicate potential biomarkers for exposure of kidney tissue

  5. A randomized dose-response trial of aerobic exercise and health-related quality of life in colon cancer survivors.

    Science.gov (United States)

    Brown, Justin C; Damjanov, Nevena; Courneya, Kerry S; Troxel, Andrea B; Zemel, Babette S; Rickels, Michael R; Ky, Bonnie; Rhim, Andrew D; Rustgi, Anil K; Schmitz, Kathryn H

    2018-04-01

    To examine the dose-response effects of aerobic exercise on health-related quality of life (HRQoL) among colon cancer survivors. Thirty-nine stage I to III colon cancer survivors were randomized to 1 of 3 groups: usual-care control, 150 min·wk -1 of aerobic exercise (low-dose) and 300 min·wk -1 of aerobic exercise (high-dose) for 6 months. HRQoL outcomes included the Short Form (SF)-36 physical and mental component summary, Functional Assessment of Cancer Therapy-Colorectal, Pittsburgh Sleep Quality Index, Fear of Cancer Recurrence Inventory, Fatigue Symptom Inventory, and North Central Cancer Treatment Group bowel function questionnaire, assessed at baseline and post intervention. The primary hypothesis was that exercise would improve HRQoL outcomes in a dose-response fashion, such that high-dose aerobic exercise would yield the largest improvements in HRQoL outcomes. Over 6 months, the low-dose group completed 141 ± 10 min·wk -1 of aerobic exercise, and the high-dose group completed 247 ± 11 min·wk -1 of aerobic exercise. Over 6 months, exercise improved the physical component summary score of the SF-36 (P trend  = 0.002), the Functional Assessment of Cancer Therapy-Colorectal (P trend  = 0.025), the Pittsburgh Sleep Quality Index (P trend  = 0.049), and the Fatigue Symptom Inventory (P trend  = 0.045) in a dose-response fashion. Between-group standardized mean difference effects sizes for the above-described findings were small to moderate in magnitude (0.35-0.75). No dose-response effects were observed for the mental component summary score of the SF-36, the Fear of Cancer Recurrence Inventory, or bowel function. Higher doses of aerobic exercise, up to 300 min·wk -1 , improve multiple HRQoL outcomes among stage I to III colon cancer survivors. These findings provide evidence that aerobic exercise may provide multiple health benefits for colon cancer survivors. Copyright © 2018 John Wiley & Sons, Ltd.

  6. Relapse of imported Plasmodium vivax malaria is related to primaquine dose: a retrospective study

    Directory of Open Access Journals (Sweden)

    Townell Nicola

    2012-06-01

    Full Text Available Abstract Background Relapsing Plasmodium vivax infection results in significant morbidity for the individual and is a key factor in transmission. Primaquine remains the only licensed drug for prevention of relapse. To minimize relapse rates, treatment guidelines have recently been revised to recommend an increased primaquine dose, aiming to achieve a cumulative dose of ≥6 mg/kg, i.e. ≥420 mg in a 70 kg patient. The aims of this study were to characterize the epidemiology of P. vivax infection imported into Queensland Australia, to determine the rates of relapse, to investigate the use of primaquine therapy, and its efficacy in the prevention of relapse. Methods A retrospective study was undertaken of laboratory confirmed P. vivax infection presenting to the two major tertiary hospitals in Queensland, Australia between January 1999 and January 2011. Primaquine dosing was classified as no dose, low dose ( Results Twenty relapses occurred following 151 primary episodes of P. vivax infection (13.2%. Relapses were confirmed among 3/21 (14.2%, 9/50 (18.0%, 1/54 (1.9% and 7/18 (38.9% of patients administered no dose, low dose, high dose and unknown primaquine dose respectively. High dose primaquine therapy was associated with a significantly lower rate of relapse compared to patients who were prescribed low dose therapy (OR 11.6, 95% CI 1.5-519, p = 0.005. Conclusions Relapse of P. vivax infection is more likely in patients who received low dose primaquine therapy. This study supports the recommendations that high dose primaquine therapy is necessary to minimize relapse of P. vivax malaria.

  7. Effect of source term composition on offsite doses

    International Nuclear Information System (INIS)

    Karahalios, P.; Gardner, R.

    1985-01-01

    The development of new realistic accident source terms has identified the need to establish a basis for comparing the impact of such source terms. This paper attempts to develop a generalized basis of comparison by investigating contributions to offsite acute whole body doses from each group of radionuclides being released to the atmosphere, using CRAC2. The paper also investigates the effect of important parameters such as regional meteorology, sheltering, and duration of release. Finally, the paper focuses on significant changes in the relative importance of individual radionuclide groups in PWR2, SST1, and a revision of the Stone and Webster proposed interim source term

  8. The relative contributions of forest growth and areal expansion to forest biomass carbon

    Science.gov (United States)

    P. Li; J. Zhu; H. Hu; Z. Guo; Y. Pan; R. Birdsey; J. Fang

    2016-01-01

    Forests play a leading role in regional and global terrestrial carbon (C) cycles. Changes in C sequestration within forests can be attributed to areal expansion (increase in forest area) and forest growth (increase in biomass density). Detailed assessment of the relative contributions of areal expansion and forest growth to C sinks is crucial to reveal the mechanisms...

  9. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  10. Radiation-related ophthalmologic changes and aging among the atomic bomb survivors

    International Nuclear Information System (INIS)

    Otake, Masanori; Finch, S.C.; Choshi, Kanji; Takaku, Isao; Mishima, Hiromu; Takase, Tomoko.

    1993-05-01

    The relationship of ionizing radiation to the age-related ophthalmologic findings of the 1978-80 ophthalmologic examination of the atomic bomb (A-bomb) survivors of Hiroshima and Nagasaki has been reanalyzed using Dosimetry System 1986 eye organ dose estimates. The main purpose of this re-evaluation was to determine whether age and radiation exposure have an additive, synergistic, or antagonistic effect on ophthalmologic changes. The best model fitting axial opacities gives a significant positive effect for both linear dose-response and linear age-related regression coefficients and a significant negative effect for an interaction between radiation dose and age. Such a negative interaction implies an antagonistic effect in that the relative risks with relation to radiation doses decrease with increasing age. This phenomenon suggests that the lenses of younger persons are more sensitive to radiation than are those of older persons. However, the best-fitting relationship for posterior subcapsular changes suggested a linear-quadratic dose response and linear age-related effects. The quadratic estimate of radiation dose squared showed a highly significant effect with a negative trend, but the negative quadratic estimate was so extremely small it had almost no contributive value within an appropriative dose area. These data suggest an additive relationship between aging and radiation for the induction of posterior subcapsular changes, and they also indicate that there is no distinct evidence of a radiation-induced aging effect. The radiation-related relative risks increase with a log linearity. The decrease of visual acuity and accommodation with increasing age were comparable in both exposed and control subjects, with age-related visual acuity decreasing more than accommodation. (J.P.N.)

  11. Activation of calcitonin gene-related peptide receptor during ozone inhalation contributes to airway epithelial injury and repair.

    Science.gov (United States)

    Oslund, Karen L; Hyde, Dallas M; Putney, Leialoha F; Alfaro, Mario F; Walby, William F; Tyler, Nancy K; Schelegle, Edward S

    2009-10-01

    The authors investigated the importance of the neuropeptide, calcitonin gene-related peptide (CGRP), in epithelial injury, repair, and neutrophil emigration after ozone exposure. Wistar rats were administered either a CGRP-receptor antagonist (CGRP(8-37)) or saline and exposed to 8 hours of 1-ppm ozone or filtered air with an 8-hour postexposure period. Immediately after exposure, ethidium homodimer was instilled into lungs as a marker of necrotic airway epithelial cells. After fixation, airway dissected lung lobes were stained for 5'-bromo-2'-deoxyuridine, a marker of epithelial proliferation. Positive epithelial cells were quantified in specific airway generations. Rats treated with CGRP(8-37) had significantly reduced epithelial injury in terminal bronchioles and reduced epithelial proliferation in proximal airways and terminal bronchioles. Bronchoalveolar lavage and sections of terminal bronchioles showed no significant difference in the number of neutrophils emigrating into airways in CGRP(8-37)-treated rats. The airway epithelial cell line, HBE-1, showed no difference in the number of oxidant stress positive cells during exposure to hydrogen peroxide and a range of CGRP(8-37) doses, demonstrating no antioxidant effect of CGRP(8-37). We conclude that activation of CGRP receptors during ozone inhalation contributes to airway epithelial injury and subsequent epithelial proliferation, a critical component of repair, but does not influence neutrophil emigration into airways.

  12. Silicon diodes as an alternative to diamond detectors for depth dose curves and profile measurements of photon and electron radiation

    International Nuclear Information System (INIS)

    Scherf, Christian; Moog, Jussi; Licher, Joerg; Kara, Eugen; Roedel, Claus; Ramm, Ulla; Peter, Christiane; Zink, Klemens

    2009-01-01

    Background: Depth dose curves and lateral dose profiles should correspond to relative dose to water in any measured point, what can be more or less satisfied with different detectors. Diamond as detector material has similar dosimetric properties like water. Silicon diodes and ionization chambers are also commonly used to acquire dose profiles. Material and Methods: The authors compared dose profiles measured in an MP3 water phantom with a diamond detector 60003, unshielded and shielded silicon diodes 60008 and 60012 and a 0.125-cm 3 thimble chamber 233642 (PTW, Freiburg, Germany) for 6- and 25-MV photons. Electron beams of 6, 12 and 18 MeV were investigated with the diamond detector, the unshielded diode and a Markus chamber 23343. Results: The unshielded diode revealed relative dose differences at the water surface below +10% for 6-MV and +4% for 25-MV photons compared to the diamond data. These values decreased to less than 1% within the first millimeters of water depth. The shielded diode was only required to obtain correct data of the fall-off zones for photon beams larger than 10 x 10 cm 2 because of important contributions of low-energy scattered photons. For electron radiation the largest relative dose difference of -2% was observed with the unshielded silicon diode for 6 MeV within the build-up zone. Spatial resolutions were always best with the small voluminous silicon diodes. Conclusion: Relative dose profiles obtained with the two silicon diodes have the same degree of accuracy as with the diamond detector. (orig.)

  13. Silicon diodes as an alternative to diamond detectors for depth dose curves and profile measurements of photon and electron radiation.

    Science.gov (United States)

    Scherf, Christian; Peter, Christiane; Moog, Jussi; Licher, Jörg; Kara, Eugen; Zink, Klemens; Rödel, Claus; Ramm, Ulla

    2009-08-01

    Depth dose curves and lateral dose profiles should correspond to relative dose to water in any measured point, what can be more or less satisfied with different detectors. Diamond as detector material has similar dosimetric properties like water. Silicon diodes and ionization chambers are also commonly used to acquire dose profiles. The authors compared dose profiles measured in an MP3 water phantom with a diamond detector 60003, unshielded and shielded silicon diodes 60008 and 60012 and a 0.125-cm(3) thimble chamber 233642 (PTW, Freiburg, Germany) for 6- and 25-MV photons. Electron beams of 6, 12 and 18 MeV were investigated with the diamond detector, the unshielded diode and a Markus chamber 23343. The unshielded diode revealed relative dose differences at the water surface below +10% for 6-MV and +4% for 25-MV photons compared to the diamond data. These values decreased to less than 1% within the first millimeters of water depth. The shielded diode was only required to obtain correct data of the fall-off zones for photon beams larger than 10 x 10 cm(2) because of important contributions of low-energy scattered photons. For electron radiation the largest relative dose difference of -2% was observed with the unshielded silicon diode for 6 MeV within the build-up zone. Spatial resolutions were always best with the small voluminous silicon diodes. Relative dose profiles obtained with the two silicon diodes have the same degree of accuracy as with the diamond detector.

  14. 29 CFR 2509.94-3 - Interpretive bulletin relating to in-kind contributions to employee benefit plans.

    Science.gov (United States)

    2010-07-01

    ... employee benefit plans. 2509.94-3 Section 2509.94-3 Labor Regulations Relating to Labor (Continued) EMPLOYEE BENEFITS SECURITY ADMINISTRATION, DEPARTMENT OF LABOR GENERAL INTERPRETIVE BULLETINS RELATING TO...-kind contributions to employee benefit plans. (a) General. This bulletin sets forth the views of the...

  15. Nominal Performance Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    Wasiolek, M.

    2000-01-01

    The purpose of this report was to document the process leading to development of the Biosphere Dose Conversion Factors (BDCFs) for the postclosure nominal performance of the potential repository at Yucca Mountain. BDCF calculations concerned twenty-four radionuclides. This selection included sixteen radionuclides that may be significant nominal performance dose contributors during the compliance period of up to 10,000 years, five additional radionuclides of importance for up to 1 million years postclosure, and three relatively short-lived radionuclides important for the human intrusion scenario. Consideration of radionuclide buildup in soil caused by previous irrigation with contaminated groundwater was taken into account in the BDCF development. The effect of climate evolution, from the current arid conditions to a wetter and cooler climate, on the BDCF values was evaluated. The analysis included consideration of different exposure pathway's contribution to the BDCFs. Calculations of nominal performance BDCFs used the GENII-S computer code in a series of probabilistic realizations to propagate the uncertainties of input parameters into the output. BDCFs for the nominal performance, when combined with the concentrations of radionuclides in groundwater allow calculation of potential radiation doses to the receptor of interest. Calculated estimates of radionuclide concentration in groundwater result from the saturated zone modeling. The integration of the biosphere modeling results (BDCFs) with the outcomes of the other component models is accomplished in the Total System Performance Assessment (TSPA) to calculate doses to the receptor of interest from radionuclides postulated to be released to the environment from the potential repository at Yucca Mountain

  16. Quantifying the relative contributions of divisive and subtractive feedback to rhythm generation.

    Directory of Open Access Journals (Sweden)

    Joël Tabak

    2011-04-01

    Full Text Available Biological systems are characterized by a high number of interacting components. Determining the role of each component is difficult, addressed here in the context of biological oscillations. Rhythmic behavior can result from the interplay of positive feedback that promotes bistability between high and low activity, and slow negative feedback that switches the system between the high and low activity states. Many biological oscillators include two types of negative feedback processes: divisive (decreases the gain of the positive feedback loop and subtractive (increases the input threshold that both contribute to slowly move the system between the high- and low-activity states. Can we determine the relative contribution of each type of negative feedback process to the rhythmic activity? Does one dominate? Do they control the active and silent phase equally? To answer these questions we use a neural network model with excitatory coupling, regulated by synaptic depression (divisive and cellular adaptation (subtractive feedback. We first attempt to apply standard experimental methodologies: either passive observation to correlate the variations of a variable of interest to system behavior, or deletion of a component to establish whether a component is critical for the system. We find that these two strategies can lead to contradictory conclusions, and at best their interpretive power is limited. We instead develop a computational measure of the contribution of a process, by evaluating the sensitivity of the active (high activity and silent (low activity phase durations to the time constant of the process. The measure shows that both processes control the active phase, in proportion to their speed and relative weight. However, only the subtractive process plays a major role in setting the duration of the silent phase. This computational method can be used to analyze the role of negative feedback processes in a wide range of biological rhythms.

  17. Optimization of Patient Doses in Interventional Radiology and Cardiology

    International Nuclear Information System (INIS)

    Nikodemova, D.; Boehm, K.

    2011-01-01

    Interventional radiology and cardiology belongs to the imaging modalities connected with significantly higher radiation exposure of patients and medical staff, compared to the exposure during other diagnostic procedures. The objective of this presentation is to promote typical technical parameters and parameters related to the radiation policy, used during the most frequent endovascular and cardiology procedures, as well as the monitoring of the exposure of patients. The presented study reports the results of collecting the data of monitoring doses received by 318 patients undergoing interventional examinations in 3 various departments of the Slovak National Institute of Cardiology and Vascular Diseases. There were 9 different endovascular and cardiology procedures reviewed. The reported patient's radiation exposures were established by using the KAP values, directly shown on the display of the X-ray equipment. From the measured KAP values the entrance surface doses were calculated. Equivalent doses have been measured on hands, legs and other parts of medical staff body, by using electronic dosimeters or thermoluminescent dosimeters. The presented results have covered a wide range of the measured fluoroscopy time values, different number of acquisitions used in various interventional procedures, various cumulated KAP values and also a wide range of the cumulated entrance surface doses. The occupational doses of the operators, followed during dose measurements on their left hands, covered the range from 0.1 μSv to 1513 μSv for one examination performed. The important contribution of the presented results to the radiation protection policy in the Slovak Republic is the mapping of the current situation of the radiation exposure of patients undergoing the chosen interventional examinations and the professional radiation exposure level of interventional operators, providing the most significant interventional procedures in the Slovak interventional hospitals. The

  18. Non-work-related personal events contribute to depressive symptoms in Japanese discretionary workers.

    Science.gov (United States)

    Ogami, Ayumi; Muto, Takashi; Haruyama, Yasuo; Yoshikawa, Toru

    2013-08-01

    In Japan, the number of workers with depressive symptoms has increased recently, and long working hours are considered one of the main contributing factors. Currently, the number of workers engaging in discretionary work is small but is expected to increase, as a diverse method of employment is believed to contribute to workers' well-being. However, the factors related to discretionary workers' depressive symptoms are unclear. This study aimed to identify the factors associated with depressive symptoms in discretionary workers. The subjects were 240 male discretionary workers in a Japanese insurance company. A cross-sectional study was performed using a questionnaire that includes demographic characteristics, living and working conditions, work-related and non-work-related stressful events, and the Center for Epidemiologic Studies Depression Scale (CES-D). Depressive symptoms were assessed as more than 16 points on the CES-D. Multiple logistic regression models were employed to estimate odd ratios (OR) with 95% confidence intervals (95% CI) of depressive symptoms in relation to possible factors. Thirty-six subjects (15.5%) showed depressive symptoms. The depressive symptoms were significantly related to age (p = 0.04), presence of child(ren) (p = 0.02), and length of employment (p = 0.01), but unrelated to working hours. Subjects who reported "financial matters" (OR = 4.50, 95% CI = 1.89-10.72) and "own event" such as divorce or illness (OR = 2.93, 95% CI = 1.13-7.61) were more likely to show depressive symptoms. In conclusion, mental health measures for discretionary workers should focus on addressing financial difficulties and consultations and assistance in personal health and family issues.

  19. Biostatnet workshop on Biomedical (Big) Data & DoReMi LD-RadStats: Workshop for statisticians interested in contributing to EU low dose radiation research

    CERN Document Server

    Calle, MLuz; Cardis, Elisabeth; Einbeck, Jochen; Gómez, Guadalupe; Puig, Pere

    2017-01-01

    This two-part volume gathers extended conference abstracts corresponding to selected talks from the "Biostatnet workshop on Biomedical (Big) Data" and from the "DoReMi LD-RadStats: Workshop for statisticians interested in contributing to EU low dose radiation research", which were held at the Centre de Recerca Matemàtica (CRM) in Barcelona from November 26th to 27th, 2015, and at the Institut de Salut Global ISGlobal (former CREAL) from October 26th to 28th, 2015, respectively. Most of the contributions are brief articles, presenting preliminary new results not yet published in regular research journals. The first part is devoted to the challenges of analyzing so called "Biomedical Big Data", tremendous amounts of biomedical and health data that are generated every day due to the use of recent technological advances such as massive genomic sequencing, electronic health records or high-resolution medical imaging, among others. The analysis of this information poses significant challenges for researchers in th...

  20. Comparison of fixed low dose versus high dose radioactive iodine for the treatment of hyperthyroidism: retrospective multifactorial analysis impacting the outcome of therapy

    International Nuclear Information System (INIS)

    Suresh Kumar, A.C.; Malhotra, G.; Basu, S.; Asopa, R.V.

    2010-01-01

    Full text: Radioactive iodine ( 131 I) as a fixed dose protocol is widely used for treatment of hyperthyroidism. However, there is no consensus on the best optimum dose for an individual patient. The objectives of this study were to observe the outcome of 131 I therapy in patients of primary hyperthyroidism in relation to fixed low dose versus high dose regimen, impact of antithyroid drugs and influence of thyroid gland size on therapy outcome. Materials and Methods: Study design: Retrospective analysis. Study group included 287 diagnosed patients of primary hyperthyroidism who had undergone 131 I therapy for the first time (68 M, 219 F; Mean age ± S.D.: 43.84 ± 12.53). All patients with low RAIU, thyrocardiac disease were excluded. Details of antithyroid (ATD) drug treatment were recorded. Analysis was done from 2002 till patients became euthyroid/hypothyroid or until January 2010. Each patient's response was evaluated initially at 6 weeks and thereafter every three months. Appropriate statistical tests were applied to compare treatment response between the groups. A P value<0.05 was considered significant. Results: Of 287 patients, 209 patients had been administered low dose (Mean ± S.D.: 4.68 ± 0.62 mCi) while 78 patients had received high dose (Mean ± S.D.: 9.15 ± 1.05 mCi) of radioiodine. 57.9% (121/ 209) patients in the low dose group responded as compared to 75.6% (59/78) in high dose group after a follow up of more than 36 months. Similarly, among patients with and without antithyroid drug treatment, grade II and above goiters the response rates were significantly higher for high dose group as compared to low dose group. Conclusion: We suggest that high dose radioiodine treatment with 8 to 10 mCi is effective in treating hyperthyroidism in patients with a better success rate than the low dose treatment with 3 to 5 mCi. This is also likely to be helpful in patients who have not received antithyroid drugs. It appears that clinically relevant

  1. Tomographic anthropomorphic models. Pt. 2. Organ doses from computed tomographic examinations in paediatric radiology

    International Nuclear Information System (INIS)

    Zankl, M.; Panzer, W.; Drexler, G.

    1993-11-01

    This report provides a catalogue of organ dose conversion factors resulting from computed tomographic (CT) examinations of children. Two radiation qualities and two exposure geometries were simulated as well as the use of asymmetrical beams. The use of further beam shaping devices was not considered. The organ dose conversion factors are applicable to babies at the age of ca. 2 months and to children between 5 and 7 years but can be used for other ages as well with the appropriate adjustments. For the calculations, the patients were represented by the GSF tomographic anthropomorphic models BABY and CHILD. The radiation transport in the body was simulated using a Monte Carlo method. The doses are presented as conversion factors of mean organ doses per air kerma free in air on the axis of rotation. Mean organ dose conversion factors are given per organ and per scanned body section of 1 cm height. The mean dose to an organ resulting from a particular CT examination can be estimated by summing up the contributions to the organ dose from all relevant sections. To facilitate the selection of the appropriate sections, a table is given which relates the tomographic models' coordinates to certain anatomical landmarks in the human body. (orig.)

  2. An epidemiological study for the reduction of population radiation dose

    International Nuclear Information System (INIS)

    Gamo, Makoto

    1989-01-01

    The correlation of tube voltage with patient exposure was studied using effective dose as an indicator of dose reduction in intraoral radiography. The results were as follows: l. The salivary gland tissues contributed the most to the effective dose of intraoral radiography. 2. In the 50 to 90 kV range, there was no appreciable correlation between tube voltage and effective dose. 3. Therefore, it was suggested that adjusting the tube voltage for maximum image quality does not effect radiation protection. 4. This study reconfirmed the fact that increases in voltages up to 90 kV reduce skin doses. (author)

  3. A preliminary examination of audience-related communications issues for the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, C.W.

    1991-04-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project will estimate radiation doses people may have received from exposure to radioactive materials released during past operations at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. The HEDR Project was initiated in response to public concerns about possible health impacts from past releases of radioactive materials from Hanford. The TSP recognized early in the project that special mechanisms would be required to effectively communicate to the many different concerned audiences. Accordingly, the TSP directed PNL to examine methods for communicating causes and effects of uncertainties in the dose estimates. After considering the directive and discussing it with the Communications Subcommittee of the TSP, PNL undertook a broad investigation of communications methods to consider for inclusion in the TSP's current communications program. As part of this investigation, a literature review was conducted regarding risk communications. A key finding was that, in order to successfully communicate risk-related information, a thorough understanding of the knowledge level, concerns and information needs of the intended recipients (i.e., the audience) is necessary. Hence, a preliminary audience analysis was conducted as part of the present research. This report summarizes the results of this analysis. 1 ref., 9 tabs.

  4. Dose calculations for irregular fields using three-dimensional first-scatter integration

    International Nuclear Information System (INIS)

    Boesecke, R.; Scharfenberg, H.; Schlegel, W.; Hartmann, G.H.

    1986-01-01

    This paper describes a method of dose calculations for irregular fields which requires only the mean energy of the incident photons, the geometrical properties of the irregular field and of the therapy unit, and the attenuation coefficient of tissue. The method goes back to an approach including spatial aspects of photon scattering for inhomogeneities for the calculation of dose reduction factors as proposed by Sontag and Cunningham (1978). It is based on the separation of dose into a primary component and a scattered component. The scattered component can generally be calculated for each field by integration over dose contributions from scattering in neighbouring volume elements. The quotient of this scattering contribution in the irregular field and the scattering contribution in the equivalent open field is then the correction factor for scattering in an irregular field. A correction factor for the primary component can be calculated if the attenuation of the photons in the shielding block is properly taken into account. The correction factor is simply given by the quotient of primary photons of the irregular field and the primary photons of the open field. (author)

  5. Assessment of effective dose from cone beam CT imaging in SPECT/CT examination in comparison with other modalities

    International Nuclear Information System (INIS)

    Tonkopi, Elena; Ross, Andrew A.

    2016-01-01

    The aim of this study was to assess radiation dose from the cone beam computed tomography (CBCT) component of single photon emission tomography/computed tomography (SPECT/CT) examinations and to compare it with the radiopharmaceutical related dose as well as dose from multidetector computed tomography (MDCT). Effective dose (ED) from computed tomography (CT) was estimated using dose-length product values and anatomy-specific conversion factors. The contribution from the SPECT component was evaluated using ED per unit administered activity for the radiopharmaceuticals listed in the International Commission on Radiological Protection Publications 80 and 106. With the exception of cardiac studies (0.11 mSv), the CBCT dose (3.96-6.04 mSv) was similar to that from the radiopharmaceutical accounting for 29-56 % of the total ED from the examination. In comparison with MDCT examinations, the CBCT dose was 48 and 42 % lower for abdomen/pelvis and chest/abdomen/pelvis scans, respectively, while in the chest the CBCT scan resulted in higher dose (23 %). Radiation dose from the CT component should be taken into consideration when evaluating total SPECT/CT patient dose. (authors)

  6. Modeling of radiation doses from chronic aqueous releases

    International Nuclear Information System (INIS)

    Watts, J.R.

    1976-01-01

    A general model and corresponding computer code were developed to calculate personnel dose estimates from chronic releases via aqueous pathways. Potential internal dose pathways are consumption of water, fish, crustacean, and mollusk. Dose prediction from consumption of fish, crustacean, or mollusk is based on the calculated radionuclide content of the water and applicable bioaccumulation factor. 70-year dose commitments are calculated for whole body, bone, lower large intestine of the gastrointestinal tract, and six internal organs. In addition, the code identifies the largest dose contributor and the dose percentages for each organ-radionuclide combination in the source term. The 1974 radionuclide release data from the Savannah River Plant were used to evaluate the dose models. The dose predicted from the model was compared to the dose calculated from radiometric analysis of water and fish samples. The whole body dose from water consumption was 0.45 mrem calculated from monitoring data and 0.61 mrem predicted from the model. Tritium contributed 99 percent of this dose. The whole body dose from fish consumption was 0.20 mrem calculated from monitoring data and 0.14 mrem from the model. Cesium-134,137 was the principal contributor to the 70-year whole body dose from fish consumption

  7. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  8. Doses to patients from diagnostic radiology in Romania

    International Nuclear Information System (INIS)

    Iacob, O.; Diaconescu, C.

    2001-01-01

    Effective doses to over 2400 patients undergoing 20 of the most important types of X-ray examinations have been estimated from entrance surface doses or dose-area products, measured in 27 X-ray departments, and the appropriate conversion coefficients calculated by the NRPB for six mathematical phantoms representing 0, 1, 5, 10, 15 year old children and the adult. The patient-weighted mean effective dose from X-ray examinations performed annually in Romania is 1.32 mSv, with 1.40 mSv for the average adult patient and 0,59 mSv for the average paediatric patient. The corresponding annual collective effective dose is about 13,430 man Sv, with the main contribution belonging to adult patients (95%), the remainder of 5 percent - to paediatric patients. (author)

  9. Neon-20 depth-dose relations in water

    Science.gov (United States)

    Wilson, J. W.; Townsend, L. W.; Bidasaria, H. B.; Schimmerling, W.; Wong, M.; Howard, J.

    1984-05-01

    The dose from heavy ion beams has been calculated using a one-dimensional transport theory and evaluated for 670 MeV/amu 20 Ne beams in water. The result is presented so as to be applicable to arbitrary ions for which the necessary interaction data are known. The present evaluation is based on thar Silberg-Tsao fragmentation parameters augmented with light fragment production from intranuclear cascades, recently calculated nuclear absorption cross sections, and evaluated stopping power data. Comparison with recent experimental data obtained at the Lawrence Berkeley Laboratory reveals the need for more accurate fragmentation data.

  10. Estimation of doses received in a dry-contaminated residential area in the Bryansk region, Russia, since the Chernobyl accident

    International Nuclear Information System (INIS)

    Andersson, K.G.; Roed, J.

    2006-01-01

    In nuclear preparedness, an essential requirement is the ability to adequately predict the likely consequences of a major accident situation. In this context it is very important to evaluate which contributions to dose are important, and which are not likely to have significance. As an example of this type of evaluation, a case study has been conducted to estimate the doses received over the first 17 years after the Chernobyl accident in a dry-contaminated residential area in the Bryansk region in Russia. Methodologies for estimation of doses received through nine different pathways, including contamination of streets, roofs, exterior walls, and landscape, are established, and best estimates are given for each of the dose contributions. Generally, contaminated soil areas were estimated to have given the highest dose contribution, but a number of other contributions to dose, e.g., from contaminated roofs and inhalation of contaminants during the passage of the contaminated plume, were of the same order of magnitude

  11. Model of organ dose combination

    International Nuclear Information System (INIS)

    Valley, J.-F.; Lerch, P.

    1977-01-01

    The ICRP recommendations are based on the limitation of the dose to each organ. In the application and for a unique source the critical organ concept allows to limit the calculation and represents the irradiation status of an individuum. When several sources of radiation are involved the derivation of the dose contribution of each source to each organ is necessary. In order to represent the irradiation status a new parameter is to be defined. Propositions have been made by some authors, in particular by Jacobi introducing at this level biological parameters like the incidence rate of detriment and its severity. The new concept is certainly richer than a simple dose notion. However, in the actual situation of knowledge about radiation effects an intermediate parameter, using only physical concepts and the maximum permissible doses to the organs, seems more appropriate. The model, which is a generalization of the critical organ concept and shall be extended in the future to take the biological effects into account, will be presented [fr

  12. Derivation, evidence and physical validity of a weighted beam-zone method for dose determination in blocked photon fields of arbitrary shape

    International Nuclear Information System (INIS)

    Glaeser, L.; Quast, U.

    1981-01-01

    A simple, practical procedure for dose determination at any point of an arbitrarily shaped field has been derived: Square-field photon beams are sectioned into a set of pyramid-shell-like parts (beam zones), nested into each other around the smallest realizable square field, of different sizes but with equal dose contributions (thus weighted) with respect to a central dose reference point. The dose at any reference point in an irregular field can be determined simply by counting the number of non-shielded dose-contributing zones (or zone fractions), leading to the associated order of square-field size (with the same number of zones), the equivalent field with known dose. For experimental evidence of the validity of the weighted beam-zone method, measurements were carried out with different high-energy photon beams with one or more beam zones shielded by absorbing blocks. Measurements were made at points in unshielded and shielded parts of the field, on and off the beam axis and at different depths in a phantom. Calculations and measurements were compared. While relative depth doses were shown to be equal to within +-2% over a range of 5 cm ahead of and behind the dose reference point, the absolute dose deviations were within +-4%. The sources of error were analysed. They were mainly determined by scattered radiation from the beam limiting device and the partial shielding deriving from the shielding blocks. The same errors also occur in most of the known methods of dose calculation in irregular fields. (author)

  13. Studies on possibility for alleviation of lifestyle diseases by low-dose irradiation or radon inhalation

    International Nuclear Information System (INIS)

    Kataoka, T.; Sakoda, A.; Yoshimoto, M.; Nakagawa, S.; Toyota, T.; Nishiyama, Y.; Yamato, K.; Ishimori, Y.; Kawabe, A.; Hanamoto, K.; Taguchi, T.; Yamaoka, K.

    2011-01-01

    Our previous studies showed the possibility that activation of the anti-oxidative function alleviates various oxidative damages, which are related to lifestyle diseases. Results showed that, low-dose X-ray irradiation activated superoxide dismutase and inhibits oedema following ischaemia-reperfusion. To alleviate ischaemia-reperfusion injury with transplantation, the changes of the anti-oxidative function in liver graft using low-dose X-ray irradiation immediately after exenteration were examined. Results showed that liver grafts activate the anti-oxidative function as a result of irradiation. In addition, radon inhalation enhances the anti-oxidative function in some organs, and alleviates alcohol-induced oxidative damage of mouse liver. Moreover, in order to determine the most effective condition of radon inhalation, mice inhaled radon before or after carbon tetrachloride (CCl 4 ) administration. Results showed that radon inhalation alleviates CCl 4 -induced hepatopathy, especially prior inhalation. It is highly possible that adequate activation of anti-oxidative functions induced by low-dose irradiation can contribute to preventing or reducing oxidative damages, which are related to lifestyle diseases. (authors)

  14. Calculation of fast neutron dose in plastic-coated optical fibers

    International Nuclear Information System (INIS)

    Siebert, B.R.L.; Henschel, H.

    1998-01-01

    The dose of fast neutrons in optical fibers with hydrogen-containing coating materials is considerably increased by energetic recoil protons. Their contribution to the dose in a SiO 2 fiber core is calculated by the Monte Carlo method for different fiber geometries and a fiber optic cable. With 14 MeV neutrons the dose in a single fiber is increased by about 21%, whereas in fiber bundles the dose increase can reach about 170%. Maximum dose enhancement in fiber bundles (about 610%) occurs at neutron energies around 5.5 MeV. The dose increase caused by 14 MeV neutrons in the fiber of a typical laboratory cable is about 124%

  15. Natural radiation dose to Gammarus from Hudson river

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Wrenn, M.E.; Eisenbud, M.

    1979-01-01

    The purpose of this investigation is to evaluate the natural radiation dose rate to whole body and components of the Gammarus species, a zooplankton which occurs in the Hudson River among other places, and to compare the results with the upper limits of dose rates from man-made sources. The alpha dose rates to the exoskeleton and soft tissues are about 10 times the average alpha dose rate to the whole body, assuming uniform distribution of 226 Ra. The natural alpha radiation dose rate to Gammarus represents only about 5% of the total natural dose to the organism, i.e., 492 mrad/yr. The external dose rate due to 40 K, 238 U plus daughters and 232 Th plus daughters accumulated in the sediments comprise 91% of that total natural dose rate, the remaining percentage being due to natural internal beta emitters and cosmic radiation. Man-made sources can cause an external dose rate up to 224 mrad/yr, which comprises roughly 1/3 of the total dose rate (up to 716 mrad/yr; natural plus man-made) to the Gammarus of Hudson River in front of Indian Point Nuclear Power Station. However, in terms of dose-equivalent the natural sources of radiation would contribute more than 75% of the total dose to Gammarus

  16. Accumulation of main radionuclides that participate in exposure dose formation in liver of wild ungulate animals on the territory of the Palesse state radioecological reserve

    International Nuclear Information System (INIS)

    Korol', R.A.; Nikitin, A.N.

    2013-01-01

    The dose of internal exposure of liver of wild ungulate animals (deer, elk, boar) mainly determined by Cs 137 at present time. The dose from Cs 137 is decrease in line wild boar - deer - elk and variate from 0.3 to 104.8 mSv/y. Other 'Chernobyl' radionuclides about equally contribute in the dose. The relative role of transuranium elements are increasing and will be equal to Cs 137 after about 250 years. The role of Sr 90 will minor all time. (authors)

  17. Occupational dose reduction developments and data collected at nuclear power plants

    International Nuclear Information System (INIS)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    Occupational dose reduction developments and data collected at nuclear power plants have been described. Written descriptions of repetitive high dose jobs, their collective dose equivalent ranges and list of dose reduction techniques will aid in reducing collective dose equivalents from these dose-reduction targets. Knowing which components contribute to high maintenance or repair dose will aid in reducing routine maintenance collective dose equivalents. The radwaste dose reduction improvements will aid in reducing radwaste operations collective dose equivalent and reduce the number of radwaste workers who exceed their administrative dose limits. The identification and rating of managers' and workers' ALARA incentives will provide the basis for recommendations to improve dose reduction incentives. Lastly, the identification and rating of the key components of an ALARA program will aid in the development and coordination of the nuclear station ALARA programs

  18. Dose and volume specification for reporting NCT. An ICRU-IAEA initiative

    International Nuclear Information System (INIS)

    Wambersie, A.; Gahbauer, R.A.; Whitmore, G.; Levin, C.V.

    2000-01-01

    The present recommendations result from of an ICRU-IAEA initiative for harmonization of reporting NCT (Neutron Capture Therapy). As stated by the ISNCT, harmonization of reporting is required to understand what has actually been done and interpret the clinical results on the basis of reliable information. Prescription of a treatment remains the responsibility of the radiation oncologist in charge of the patient. Complete oncological data should be reported, including Gross Tumor Volume (GTV) and Clinical Target Volume (CTV) as well as Planning Target Volume (PTV), Treated Volume and Organs/Structures at Risk. A reference point for reporting dose should be selected in the central part of the PTV/CTV. At each point of interest, the four components contributing to the absorbed dose and the weighting factors applied to take account of the RBE (Relative Biological Effectiveness) differences should be specified. (author)

  19. Collective doses from airborne discharges by the UK nuclear industry

    International Nuclear Information System (INIS)

    Kelly, G.N.

    1981-01-01

    Small quantities of radionuclides are discharged in airborne effluents during the normal operation of nuclear installations. The dispersion of these nuclides in the atmosphere and their subsequent transfer through various sectors of the environment leads to the irradiation of the population. The collective dose to the UK population from airborne discharges in one particular year, 1978, from UK nuclear installations is estimated. The discharges in that year are typical of those in the recent past. Consideration is given to the contribution made by each type of establishment (eg, nuclear power stations, reprocessing plants) and the nuclides which contribute significantly to the collective dose are identified. The distributions of the collective dose in time and among individuals in the exposed population are important features in determining the significance attached to it and both aspects are discussed. The collective dose can be used as a measure of the health detriment associated with the discharge practices considered and is one of several quantities to be taken into account in assessing them. The collective doses from airborne discharges are finally contrasted with those from other sources of exposure of the population. (author)

  20. Dosing-time contributes to chronotoxicity of clofarabine in mice via means other than pharmacokinetics

    Directory of Open Access Journals (Sweden)

    Jia-Jie Luan

    2016-05-01

    Full Text Available To evaluate the time- and dose-dependent toxicity of clofarabine in mice and to further define the chronotherapy strategy of it in leukemia, we compared the mortality rates, LD50s, biochemical parameters, histological changes and organ indexes of mice treated with clofarabine at various doses and time points. Plasma clofarabine levels and pharmacokinetic parameters were monitored continuously for up to 8 hours after the single intravenous administration of 20 mg/kg at 12:00 noon and 12:00 midnight by high performance liquid chromatography (HPLC-UV method. Clofarabine toxicity in all groups fluctuated in accordance with circadian rhythms in vivo. The toxicity of clofarabine in mice in the rest phase was more severe than the active one, indicated by more severe liver damage, immunodepression, higher mortality rate, and lower LD50. No significant pharmacokinetic parameter changes were observed between the night and daytime treatment groups. These findings suggest the dosing-time dependent toxicity of clofarabine synchronizes with the circadian rhythm of mice, which might provide new therapeutic strategies in further clinical application.

  1. Dose-dependent effects of the clinical anesthetic isoflurane on Octopus vulgaris: a contribution to cephalopod welfare.

    Science.gov (United States)

    Polese, Gianluca; Winlow, William; Di Cosmo, Anna

    2014-12-01

    Recent progress in animal welfare legislation relating to invertebrates has provoked interest in methods for the anesthesia of cephalopods, for which different approaches to anesthesia have been tried but in most cases without truly anesthetizing the animals. For example, several workers have used muscle relaxants or hypothermia as forms of "anesthesia." Several inhalational anesthetics are known to act in a dose-dependent manner on the great pond snail Lymnaea stagnalis, a pulmonate mollusk. Here we report, for the first time, on the effects of clinical doses of the well-known inhalational clinical anesthetic isoflurane on the behavioral responses of the common octopus Octopus vulgaris. In each experiment, isoflurane was equilibrated into a well-aerated seawater bath containing a single adult O. vulgaris. Using a web camera, we recorded each animal's response to touch stimuli eliciting withdrawal of the arms and siphon and observed changes in the respiratory rate and the chromatophore pattern over time (before, during, and after application of the anesthetic). We found that different animals of the same size responded with similar behavioral changes as the isoflurane concentration was gradually increased. After gradual application of 2% isoflurane for a maximum of 5 min (at which time all the responses indicated deep anesthesia), the animals recovered within 45-60 min in fresh aerated seawater. Based on previous findings in gastropods, we believe that the process of anesthesia induced by isoflurane is similar to that previously observed in Lymnaea. In this study we showed that isoflurane is a good, reversible anesthetic for O. vulgaris, and we developed a method for its use.

  2. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 6

    International Nuclear Information System (INIS)

    Zankl, M.; Panzer, W.; Drexler, G.

    1991-11-01

    Computed tomography (CT) is a technique which offers a high diagnostic capability; however, the dose to the patient is high compared to conventional radiography. This report provides a catalogue of organ doses resulting from CT examinations. The organ doses were calculated for the type of CT scanners most commonly used in the FRG and for three different radiation qualities. For the dose calculations, the patients were represented by the adult mathematical phantoms Adam and Eva. The radiation transport in the body was simulated using a Monte Carlo method. The doses were calculated as conversion factors of mean organ doses per air kerma free in air on the axis of rotation. Mean organ dose conversion factors are given per organ and per single CT slice of 1 cm width. The mean dose to an organ resulting from a particular CT examination can be estimated by summing up the contribution to the organ dose from each relevant slice. In order to facilitate the selection of the appropriate slices, a table is given which relates the mathematical phantoms' coordinates to certain anatomical landmarks in the human body. (orig.)

  3. Contributing risk factors for orthopedic device related infections in sina hospital, tehran, iran.

    Science.gov (United States)

    Hadadi, A; Zehtab, M J; Babagolzadeh, H; Ashraf, H

    2011-02-01

    In spite of decreasing incidence of orthopedic device-related infections to 1%, nowadays, device-related infection still remains a diagnostic, therapeutic and cost-related problem. The objective of this study is to evaluate the contributing risk factors for orthopedic device-related infections in Sina Hospital, Tehran, Iran. Three hundred and thirty patients who underwent orthopedic device implantation from 2002-2006 were enrolled; among them, 110 patients were complicated with infection. Descriptive and logistic regression analyses were performed to determine the risk factors for device related infections. Patients with infection were older compared to those without infection. The Staphylococcus aureus was the commonest organism. A correlation was observed between wound infection and external fixation, an underlying health condition, and addiction which were independent risk factors for a device related infection. Orthopedic device-related infection puts a great financial burden on patients and hospital resources and could lead to morbidity and mortality in patients. So, appropriate pre and postoperative wound care for dirty wounds, especially when external fixators are used, and in patients with poor conditions or addiction should be done with more caution.

  4. Relationship between attenuation coefficients and dose-spread kernels

    International Nuclear Information System (INIS)

    Boyer, A.L.

    1988-01-01

    Dose-spread kernels can be used to calculate the dose distribution in a photon beam by convolving the kernel with the primary fluence distribution. The theoretical relationships between various types and components of dose-spread kernels relative to photon attenuation coefficients are explored. These relations can be valuable as checks on the conservation of energy by dose-spread kernels calculated by analytic or Monte Carlo methods

  5. Comments on 'Reconsidering the definition of a dose-volume histogram'-dose-mass histogram (DMH) versus dose-volume histogram (DVH) for predicting radiation-induced pneumonitis

    International Nuclear Information System (INIS)

    Mavroidis, Panayiotis; Plataniotis, Georgios A; Gorka, Magdalena Adamus; Lind, Bengt K

    2006-01-01

    In a recently published paper (Nioutsikou et al 2005 Phys. Med. Biol. 50 L17) the authors showed that the use of the dose-mass histogram (DMH) concept is a more accurate descriptor of the dose delivered to lung than the traditionally used dose-volume histogram (DVH) concept. Furthermore, they state that if a functional imaging modality could also be registered to the anatomical imaging modality providing a functional weighting across the organ (functional mass) then the more general and realistic concept of the dose-functioning mass histogram (D[F]MH) could be an even more appropriate descriptor. The comments of the present letter to the editor are in line with the basic arguments of that work since their general conclusions appear to be supported by the comparison of the DMH and DVH concepts using radiobiological measures. In this study, it is examined whether the dose-mass histogram (DMH) concept deviated significantly from the widely used dose-volume histogram (DVH) concept regarding the expected lung complications and if there are clinical indications supporting these results. The problem was investigated theoretically by applying two hypothetical dose distributions (Gaussian and semi-Gaussian shaped) on two lungs of uniform and varying densities. The influence of the deviation between DVHs and DMHs on the treatment outcome was estimated by using the relative seriality and LKB models using the Gagliardi et al (2000 Int. J. Radiat. Oncol. Biol. Phys. 46 373) and Seppenwoolde et al (2003 Int. J. Radiat. Oncol. Biol. Phys. 55 724) parameter sets for radiation pneumonitis, respectively. Furthermore, the biological equivalent of their difference was estimated by the biologically effective uniform dose (D-bar) and equivalent uniform dose (EUD) concepts, respectively. It is shown that the relation between the DVHs and DMHs varies depending on the underlying cell density distribution and the applied dose distribution. However, the range of their deviation in terms of

  6. Effect of various methods for rectum delineation on relative and absolute dose-volume histograms for prostate IMRT treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Kusumoto, Chiaki [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Ohira, Shingo [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita (Japan); Miyazaki, Masayoshi [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Ueda, Yoshihiro [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Radiation Oncology, Graduate School of Medicine, Osaka University, Suita (Japan); Isono, Masaru [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Teshima, Teruki, E-mail: teshima-te@mc.pref.osaka.jp [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan)

    2016-07-01

    Several reports have dealt with correlations of late rectal toxicity with rectal dose-volume histograms (DVHs) for high dose levels. There are 2 techniques to assess rectal volume for reception of a specific dose: relative-DVH (R-DVH, %) that indicates relative volume for a vertical axis, and absolute-DVH (A-DVH, cc) with its vertical axis showing absolute volume of the rectum. The parameters of DVH vary depending on the rectum delineation method, but the literature does not present any standardization of such methods. The aim of the present study was to evaluate the effects of different delineation methods on rectal DVHs. The enrollment for this study comprised 28 patients with high-risk localized prostate cancer, who had undergone intensity-modulated radiation therapy (IMRT) with the prescription dose of 78 Gy. The rectum was contoured with 4 different methods using 2 lengths, short (Sh) and long (Lg), and 2 cross sections, rectum (Rec) and rectal wall (Rw). Sh means the length from 1 cm above the seminal vesicles to 1 cm below the prostate and Lg the length from the rectosigmoid junction to the anus. Rec represents the entire rectal volume including the rectal contents and Rw the rectal volume of the area with a wall thickness of 4 mm. We compared dose-volume parameters by using 4 rectal contour methods for the same plan with the R-DVHs as well as the A-DVHs. For the high dose levels, the R-DVH parameters varied widely. The mean of V{sub 70} for Sh-Rw was the highest (19.4%) and nearly twice as high as that for Lg-Rec (10.4%). On the contrary, only small variations were observed in the A-DVH parameters (4.3, 4.3, 5.5, and 5.5 cc for Sh-Rw, Lg-Rw, Sh-Rec, and Lg-Rec, respectively). As for R-DVHs, the parameters of V{sub 70} varied depending on the rectal lengths (Sh-Rec vs Lg-Rec: R = 0.76; Sh-Rw vs Lg-Rw: R = 0.85) and cross sections (Sh-Rec vs Sh-Rw: R = 0.49; Lg-Rec vs Lg-Rw: R = 0.65). For A-DVHs, however, the parameters of Sh rectal A-DVHs hardly changed

  7. Contribution of bystander effects in radiation induced genotoxicity

    International Nuclear Information System (INIS)

    Zhou, H.; Persaud, R.; Gillispie, J.; Randers-Pehrson, G.; Hei, T.K.; Suzuki, Masao

    2005-01-01

    The controversial use of a linear, no threshold extrapolation model for low dose risk assessment is based on the accepted dogma that the deleterious effects of ionizing radiation such as mutagenesis and carcinogenesis are attributable mainly to direct damage to DNA. However, this extrapolation was challenged by the recent reports on the bystander phenomenon. The bystander effect contributes to this debate by implying that the biological effects of low doses, where not all cells are traversed by a charged particle, are amplified by the transfer of factors to un-irradiated neighbors. This interested phenomenon implies that a linear extrapolation of risks from high to low doses may underestimate rather than over estimate low dose risks. Together with some radiation-induced phenomena such as adaptive response and genomic instability, the radiobiological response at low doses is likely to be a complex interplay among many factors. (author)

  8. Optimizing bevacizumab dosing in glioblastoma: less is more.

    Science.gov (United States)

    Ajlan, Abdulrazag; Thomas, Piia; Albakr, Abdulrahman; Nagpal, Seema; Recht, Lawrence

    2017-10-01

    Compared to traditional chemotherapies, where dose limiting toxicities represent the maximum possible dose, monoclonal antibody therapies are used at doses well below maximum tolerated dose. However, there has been little effort to ascertain whether there is a submaximal dose at which the efficacy/complication ratio is maximized. Thus, despite the general practice of using Bevacizumab (BEV) at dosages of 10 mg/kg every other week for glioma patients, there has not been much prior work examining whether the relatively high complication rates reported with this agent can be decreased by lowering the dose without impairing efficacy. We assessed charts from 80 patients who received BEV for glioblastoma to survey the incidence of complications relative to BEV dose. All patients were treated with standard upfront chemoradiation. The toxicity was graded based on the NCI CTCAE, version 4.03. The rate of BEV serious related adverse events was 12.5% (n = 10/80). There were no serious adverse events (≥grade 3) when the administered dose was (<3 mg/kg/week), compared to a 21% incidence in those who received higher doses (≥3 mg/kg/week) (P < 0.01). Importantly, the three patient deaths attributable to BEV administration occurred in patients receiving higher doses. Patients who received lower doses also had a better survival rate, although this did not reach statistical significance [median OS 39 for low dose group vs. 17.3 for high dose group (P = 0.07)]. Lower rates of serious BEV related toxicities are noted when lower dosages are used without diminishing positive clinical impact. Further work aimed at optimizing BEV dosage is justified.

  9. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  10. Radiation-Related New Primary Solid Cancers in the Childhood Cancer Survivor Study: Comparative Radiation Dose Response and Modification of Treatment Effects

    International Nuclear Information System (INIS)

    Inskip, Peter D.; Sigurdson, Alice J.; Veiga, Lene; Bhatti, Parveen; Ronckers, Cécile; Rajaraman, Preetha; Boukheris, Houda; Stovall, Marilyn; Smith, Susan; Hammond, Sue; Henderson, Tara O.

    2016-01-01

    Objectives: The majority of childhood cancer patients now achieve long-term survival, but the treatments that cured their malignancy often put them at risk of adverse health outcomes years later. New cancers are among the most serious of these late effects. The aims of this review are to compare and contrast radiation dose–response relationships for new solid cancers in a large cohort of childhood cancer survivors and to discuss interactions among treatment and host factors. Methods: This review is based on previously published site-specific analyses for subsequent primary cancers of the brain, breast, thyroid gland, bone and soft tissue, salivary glands, and skin among 12,268 5-year childhood cancer survivors in the Childhood Cancer Survivor Study. Analyses included tumor site–specific, individual radiation dose reconstruction based on radiation therapy records. Radiation-related second cancer risks were estimated using conditional logistic or Poisson regression models for excess relative risk (ERR). Results: Linear dose–response relationships over a wide range of radiation dose (0-50 Gy) were seen for all cancer sites except the thyroid gland. The steepest slopes occurred for sarcoma, meningioma, and nonmelanoma skin cancer (ERR/Gy > 1.00), with glioma and cancers of the breast and salivary glands forming a second group (ERR/Gy = 0.27-0.36). The relative risk for thyroid cancer increased up to 15-20 Gy and then decreased with increasing dose. The risk of thyroid cancer also was positively associated with chemotherapy, but the chemotherapy effect was not seen among those who also received very high doses of radiation to the thyroid. The excess risk of radiation-related breast cancer was sharply reduced among women who received 5 Gy or more to the ovaries. Conclusions: The results suggest that the effect of high-dose irradiation is consistent with a linear dose–response for most organs, but they also reveal important organ-specific and host

  11. Radiation-Related New Primary Solid Cancers in the Childhood Cancer Survivor Study: Comparative Radiation Dose Response and Modification of Treatment Effects

    Energy Technology Data Exchange (ETDEWEB)

    Inskip, Peter D., E-mail: inskippeter@gmail.com [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Sigurdson, Alice J.; Veiga, Lene [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Bhatti, Parveen [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Division of Public Health Sciences, Fred Hutchinson Cancer Research Center, Seattle, Washington (United States); Ronckers, Cécile [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Department of Pediatric Oncology, Emma Children' s Hospital/Academic Medical Center, Amsterdam (Netherlands); Rajaraman, Preetha [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Boukheris, Houda [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); The University of Oran School of Medicine (Algeria); Stovall, Marilyn; Smith, Susan [Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, Texas (United States); Hammond, Sue [Department of Laboratory Medicine and Pathology, Children' s Hospital and Ohio State University College of Medicine, Columbus, Ohio (United States); Henderson, Tara O. [University of Chicago Department of Pediatrics, Section of Hematology, Oncology and Stem Cell Transplantation, Chicago, Illinois (United States); and others

    2016-03-15

    Objectives: The majority of childhood cancer patients now achieve long-term survival, but the treatments that cured their malignancy often put them at risk of adverse health outcomes years later. New cancers are among the most serious of these late effects. The aims of this review are to compare and contrast radiation dose–response relationships for new solid cancers in a large cohort of childhood cancer survivors and to discuss interactions among treatment and host factors. Methods: This review is based on previously published site-specific analyses for subsequent primary cancers of the brain, breast, thyroid gland, bone and soft tissue, salivary glands, and skin among 12,268 5-year childhood cancer survivors in the Childhood Cancer Survivor Study. Analyses included tumor site–specific, individual radiation dose reconstruction based on radiation therapy records. Radiation-related second cancer risks were estimated using conditional logistic or Poisson regression models for excess relative risk (ERR). Results: Linear dose–response relationships over a wide range of radiation dose (0-50 Gy) were seen for all cancer sites except the thyroid gland. The steepest slopes occurred for sarcoma, meningioma, and nonmelanoma skin cancer (ERR/Gy > 1.00), with glioma and cancers of the breast and salivary glands forming a second group (ERR/Gy = 0.27-0.36). The relative risk for thyroid cancer increased up to 15-20 Gy and then decreased with increasing dose. The risk of thyroid cancer also was positively associated with chemotherapy, but the chemotherapy effect was not seen among those who also received very high doses of radiation to the thyroid. The excess risk of radiation-related breast cancer was sharply reduced among women who received 5 Gy or more to the ovaries. Conclusions: The results suggest that the effect of high-dose irradiation is consistent with a linear dose–response for most organs, but they also reveal important organ-specific and host

  12. The minimal melanogenesis dose/minimal erythema dose ratio declines with increasing skin pigmentation using solar simulator and narrowband ultraviolet B exposure

    DEFF Research Database (Denmark)

    Ravnbak, Mette H; Philipsen, Peter A; Wulf, Hans Christian

    2010-01-01

    To investigate the relation between pre-exposure skin pigmentation and the minimal melanogenesis dose (MMD)/minimal erythema dose (MED) ratio after a single narrowband ultraviolet B (nUVB) and solar simulator (Solar) exposure.......To investigate the relation between pre-exposure skin pigmentation and the minimal melanogenesis dose (MMD)/minimal erythema dose (MED) ratio after a single narrowband ultraviolet B (nUVB) and solar simulator (Solar) exposure....

  13. Heel Effect: Dose Mapping And Profiling For Mobile C-Arm Fluoroscopy Unit Toshiba SXT-1000A

    International Nuclear Information System (INIS)

    Husaini Salleh; Mohd Khalid Matori; Muhammad Jamal Md Isa; Mohd Ramli Arshad; Shahrul Azlan Azizan; Mohd Firdaus Abdul Rahman; Md Khairusalih Md Zin

    2014-01-01

    Heel Effect is the well known phenomena in x-ray production. It contributes the effect to image formation and as well as scattered radiation. But there is paucity in the study related to heel effect. This study is for mapping and profiling the dose on the surface of water phantom by using mobile C-arm unit Toshiba SXT-1000A. Based on the result the dose profile is increasing up to about 57 % from anode to cathode bound of the irradiated area. This result and information can be used as a guide to manipulate these phenomena for better image quality and radiation safety for this specific and dedicated fluoroscopy unit. (author)

  14. Effect of tungsten-187 in primary coolant on dose rate build-up in Vandellos 2

    International Nuclear Information System (INIS)

    Fernandez Lillo, E.; Llovet, R.; Boronat, M.

    1994-01-01

    The present work proposes a relationship between the Cobalt-60 piping deposited activity and the relatively high levels of Tungsten-187 in the coolant of Vandellos 2. The conclusions of this work can be applicable to other plants, since it proposes a tool to estimate and quantify the contribution of stellite to the generation of Cobalt-60 and the radiation dose build-up. (authors). 7 figs., 6 refs

  15. Dose-response relationships for carcinogens: a review

    International Nuclear Information System (INIS)

    Zeise, L.; Wilson, R.; Crouch, E.A.C.

    1987-01-01

    The authors review the experimental evidence for various shapes of dose-response relationships for carcinogens and summarize those experiments that give the most information on relatively low doses. A brief review of some models is given to illustrate the shapes of dose-response curve expected from them. Their major interest is in the use of dose-response relationships to estimate risks to humans at low doses, and so they pay special attention to experimentally observed and theoretically expected nonlinearities. There are few experimental examples of nonlinear dose-response relations in humans, but this may simply be due to the limitations in the data. The several examples in rodents, even though for high dose data, suggest that nonlinearity is common. In some cases such nonlinearities may be rationalized on the basis of the pharmacokinetics of the test compound or its metabolites

  16. Dose-response and concentration-response relation of rocuronium infusion during propofol nitrous oxide and isoflurane nitrous oxide anaesthesia

    NARCIS (Netherlands)

    Kansanaho, M; Olkkola, KT; Wierda, JMKH

    The dose-response and concentration-response relation of rocuronium infusion was studied in 20 adult surgical patients during proporfol-nitrous oxide and isoflurane (1 MAC) -nitrous oxide anaesthesia. Neuromuscular block was kept constant, initially at 90% and then at 50% with a closed-loop feedback

  17. Estimation of the Relative Contribution of Postprandial Glucose Exposure to Average Total Glucose Exposure in Subjects with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Bo Ahrén

    2016-01-01

    Full Text Available We hypothesized that the relative contribution of fasting plasma glucose (FPG versus postprandial plasma glucose (PPG to glycated haemoglobin (HbA1c could be calculated using an algorithm developed by the A1c-Derived Average Glucose (ADAG study group to make HbA1c values more clinically relevant to patients. The algorithm estimates average glucose (eAG exposure, which can be used to calculate apparent PPG (aPPG by subtracting FPG. The hypothesis was tested in a large dataset (comprising 17 studies from the vildagliptin clinical trial programme. We found that 24 weeks of treatment with vildagliptin monotherapy (n=2523 reduced the relative contribution of aPPG to eAG from 8.12% to 2.95% (by 64%, p<0.001. In contrast, when vildagliptin was added to metformin (n=2752, the relative contribution of aPPG to eAG insignificantly increased from 1.59% to 2.56%. In conclusion, glucose peaks, which are often prominent in patients with type 2 diabetes, provide a small contribution to the total glucose exposure assessed by HbA1c, and the ADAG algorithm is not robust enough to assess this small relative contribution in patients receiving combination therapy.

  18. Radiation damage to human erythrocytes. Relative contribution of hydroxyl and chloride radicals in N2O-saturated buffers

    International Nuclear Information System (INIS)

    Krokosz, Anita; Komorowska, Magdalena A.; Szweda-Lewandowska, Zofia

    2008-01-01

    The erythrocyte suspensions in Na-phosphate buffered isotonic NaCl solution (PBS) or Na-phosphate isotonic buffer (PB) (hematocrit 1%) were irradiated with the dose of 400 Gy under N 2 O. Erythrocytes were incubated in the medium in which the cells were irradiated or in fresh PBS. The level of damage to cells was estimated on the basis of the course of post-radiation hemolysis and hemoglobin (Hb) oxidation. The medium in which the cells were irradiated and incubated influenced the course of the post-radiation hemolysis and Hb oxidation as well as some other parameters. We discussed the contribution of hydroxyl and chloride radicals in the initiation of erythrocyte damage and oxygen modification of these processes

  19. Characterisation of blue-light stimulated luminescence components in different quartz samples: Implications for dose measurement

    DEFF Research Database (Denmark)

    Jain, M.; Murray, A.S.; Bøtter-Jensen, L.

    2003-01-01

    -aliquot dose-evaluation protocols seem to be relatively free of complications when applied to quartz dominated by the fast OSL component coming from 325degreesC TL region, but this may not be true for quartz in which other components are more significant. An adequate understanding of how different OSL...... results from measurement of (a) sensitisation, (b) thermal stability, (c) recuperation, and (d) infrared response as a function of stimulation temperature from 3 different samples of sedimentary quartz selected on the basis of relative OSL contribution from different blue light stimulated linearly...

  20. Microbiological aspects relating to the choice of radiation sterilization dose

    International Nuclear Information System (INIS)

    Whitby, J.L.

    1993-01-01

    Ionizing radiation is widely used for sterilization of single-use medical devices, and it is employed for its lethal effect on microbial life. Microbes are capable of regenerating from a single surviving cell, and individual cells of some microbial species are highly resistant to the lethal effects of radiation. It is necessary to employ radiation doses far in excess of those lethal to man or animals to ensure that no viable microbe remains to repopulate the device or the patient at the time that the device is used. Ionizations induce the production of short-lived free radicals that also induce lethal changes in cells. The sensitivity of microbial species to these changes varies markedly but since the changes are induced within the cell, each cell has to sustain the necessary amount of lethal damage before death will occur. Therefore the death of cells will occur in the exponential mode the surviving fraction decreasing with increasing dose. Using a semi-logarithmic plot, curves of three types may be generated, a simple exponential curve with a constant slope over the whole dose range, one where an initial shoulder is followed by a constant slope, and curves which are concave, and only seen in mixed bacterial populations of differing radiation resistance. (author)

  1. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    Science.gov (United States)

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  2. An updated dose assesment for resettlement options at Bikini atoll - A US nuclear test site

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1997-01-01

    There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radio nuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1978. The unique composition of coral soil greatly alters the relative contribution of 137 Cs and 90 Sr to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, 137 Cs produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 91 mSv, 130 mSv, and 150 mSv, respectively. A detailed uncertainty analysis for these dose estimates is presented in a companion paper in this issue. We have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to about 5 % of pretreatment levels and has essentially no negative environmental consequences. We have calculated the dose for the rehabilitation scenario where the top 40 cm of soil is removed in the housing and village area, and the rest of the island is treated with potassium fertilizer; the maximum annual effective dose is 0.41 mSv and the 30-, 50-, and 70-y integral effective doses are 9.8 mSv, 14 mSv, and 16 mSv, respectively. 44 refs., 3 figs., 11 tabs

  3. Transient impairment of hippocampus-dependent learning and memory in relatively low-dose of acute radiation syndrome is associated with inhibition of hippocampal neurogenesis

    International Nuclear Information System (INIS)

    Kim, Joong-Sun; Lee, Hae-June; Kim, Jong-Choon

    2008-01-01

    Neurogenesis in the adult hippocampus, which occurs constitutively, is vulnerable to ionizing radiation. In the relatively low-dose exposure of acute radiation syndrome (ARS), the change in the adult hippocampal function is poorly understood. This study analyzed the changes in apoptotic cell death and neurogenesis in the DGs of hippocampi from adult ICR mice with single whole-body gamma-irradiation using the TdT-mediated dUTP-biotin nick end-labeling (TUNEL) method and immunohistochemical markers of neurogenesis, Ki-67 and doublecortin (DCX). In addition, the hippocampus-dependent learning and memory tasks after single whole-body gamma-irradiation were examined in order to evaluate the hippocampus-related behavioral dysfunction in the relatively low-dose exposure of ARS. The number of TUNEL-positive apoptotic nuclei in the dentate gyrus (DG) was increased 6-12 h after acute gamma-irradiation (a single dose of 0.5 to 4 Gy). In contrast, the number of Ki-67- and DCX-positive cells began to decrease significantly 6 h postirradiation, reaching its lowest level 24 h after irradiation. The level of Ki-67 and DCX immunoreactivity decreased in a dose-dependent manner within the range of irradiation applied (0-4 Gy). In passive avoidance and object recognition memory test, the mice trained 1 day after acute irradiation (2 Gy) showed significant memory deficits, compared with the sham controls. In conclusion, the pattern of the hippocampus-dependent memory dysfunction is consistent with the change in neurogenesis after acute irradiation. It is suggested that a relatively low dose of ARS in adult ICR mice is sufficiently detrimental to interrupt the functioning of the hippocampus, including learning and memory, possibly through the inhibition of neurogenesis. (author)

  4. High-dose total-body irradiation and autologous marrow reconstitution in dogs: dose-rate-related acute toxicity and fractionation-dependent long-term survival

    International Nuclear Information System (INIS)

    Deeg, H.J.; Storb, R.; Weiden, P.L.; Schumacher, D.; Shulman, H.; Graham, T.; Thomas, E.D.

    1981-01-01

    Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs died from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors

  5. Contribution to the study of nuclear processes in hadron therapy and their impact on the dose deposition delocalization

    International Nuclear Information System (INIS)

    Ricol, M.Ch.

    2008-11-01

    This work aims to improve the predictive power of monte Carlo simulation programmes of the volume distributions of dose deposit in hadron therapy. The monte Carlo simulations show the electromagnetic interactions in hadron therapy but not the nuclear interactions responsible of a dose deposit relocation. A better quantification of these nuclear phenomena in order to get a more precise knowledge of the dose deposit relocation constitutes the object of this work. (N.C.)

  6. Care Aides' Relational Practices and Caring Contributions.

    Science.gov (United States)

    Andersen, Elizabeth A; Spiers, Jude

    2016-11-01

    HOW TO OBTAIN CONTACT HOURS BY READING THIS ARTICLE INSTRUCTIONS 1.2 contact hours will be awarded by Villanova University College of Nursing upon successful completion of this activity. A contact hour is a unit of measurement that denotes 60 minutes of an organized learning activity. This is a learner-based activity. Villanova University College of Nursing does not require submission of your answers to the quiz. A contact hour certificate will be awarded once you register, pay the registration fee, and complete the evaluation form online at http://goo.gl/gMfXaf. To obtain contact hours you must: 1. Read the article, "Care Aides' Relational Practices and Caring Contributions" found on pages 24-30, carefully noting any tables and other illustrative materials that are included to enhance your knowledge and understanding of the content. Be sure to keep track of the amount of time (number of minutes) you spend reading the article and completing the quiz. 2. Read and answer each question on the quiz. After completing all of the questions, compare your answers to those provided within this issue. If you have incorrect answers, return to the article for further study. 3. Go to the Villanova website listed above to register for contact hour credit. You will be asked to provide your name; contact information; and a VISA, MasterCard, or Discover card number for payment of the $20.00 fee. Once you complete the online evaluation, a certificate will be automatically generated. This activity is valid for continuing education credit until October 31, 2019. CONTACT HOURS This activity is co-provided by Villanova University College of Nursing and SLACK Incorporated. Villanova University College of Nursing is accredited as a provider of continuing nursing education by the American Nurses Credentialing Center's Commission on Accreditation. ACTIVITY OBJECTIVES 1. Define the application of Swanson's Middle Range Theory of Caring in care aides' relational care practices for nursing home

  7. Factors Associated with Myelosuppression Related to Low-Dose Methotrexate Therapy for Inflammatory Rheumatic Diseases

    Science.gov (United States)

    Mori, Shunsuke; Hidaka, Michihiro; Kawakita, Toshiro; Hidaka, Toshihiko; Tsuda, Hiroyuki; Yoshitama, Tamami; Migita, Kiyoshi; Ueki, Yukitaka

    2016-01-01

    Objective Severe myelosuppression is a serious concern in the management of rheumatic disease patients receiving methotrexate (MTX) therapy. This study was intended to explore factors associated with the development of MTX-related myelosuppression and its disease severity. Methods We retrospectively examined a total of 40 cases of MTX-related myelosuppression that had been filed in the registries of participating rheumatology and hematology divisions. Data before onset were compared with those of 120 controls matched for age and sex. Cytopenia was graded according to the National Cancer Institute criteria for adverse events. Data before and at onset were compared between the severe and non-severe groups. Results Non-use of folic acid supplements, concurrent medications, and low renal function were significantly associated with the development of myelosuppression (p disease severity was not dependent on MTX doses. Serum albumin levels and folic acid supplementation are the important factors affecting the severity of MTX-related pancytopenia and neutropenia. PMID:27128679

  8. Does a dose-response relation exist between spinal pain and temporomandibular disorders?

    Directory of Open Access Journals (Sweden)

    Englund Erling

    2009-03-01

    Full Text Available Abstract Background The aim of this study was to test whether a reciprocal dose-response relation exists between frequency/severity of spinal pain and temporomandibular disorders (TMD. Methods A total of 616 subjects with varying severity of spinal pain or no spinal pain completed a questionnaire focusing on symptoms in the jaw, head and spinal region. A subset of the population (n = 266 were sampled regardless of presence or absence of spinal pain. We used two different designs, one with frequency/severity of spinal pain, and the other, with frequency/severity of TMD symptoms as independent variable. All 616 participants were allocated to four groups, one control group without spinal pain and three spinal pain groups. The subjects in the subset were allocated to one control group without TMD symptoms and three TMD groups. Odds ratios (ORs were calculated for presence of frequent TMD symptoms in the separate spinal pain groups as well as for frequent spinal pain in the separate TMD groups. Results The analysis showed increasing ORs for TMD with increasing frequency/severity of spinal pain. We also found increasing ORs for spinal pain with increasing frequency/severity of TMD symptoms. Conclusion This study shows a reciprocal dose-response-like relationship between spinal pain and TMD. The results indicate that these two conditions may share common risk factors or that they may influence each other. Studies on the temporal sequence between spinal pain and TMD are warranted.

  9. Doses to the red bone marrow of young people and adults from radiation of natural origin

    International Nuclear Information System (INIS)

    Kendall, G M; Fell, T P

    2011-01-01

    Natural radiation sources comprise cosmic rays, terrestrial gamma rays, radionuclides in food and inhaled isotopes of radon with their decay products. These deliver doses to all organs and tissues including red bone marrow (RBM), the tissue in which leukaemia is thought to originate. In this paper we calculate the age-dependent annual RBM doses from natural radiation sources to young people and to adults at average levels of exposure in the UK. The contributions to dose are generally less complex than in the case of doses to foetuses and young children where it is necessary to take into account transfer of radionuclides across the placenta, intakes in mother's milk and changes in gut uptake in young infants. However, there is high uptake of alkaline earths and of similar elements in the developing skeleton and this significantly affects the doses from radioisotopes of these elements, not just in the teens and twenties but through into the fifth decade of life. The total equivalent dose to the RBM from all natural sources of radiation at age 15 years is calculated to be about 1200 μSv a year at average UK levels, falling to rather less than 1100 μSv per year in later life; the gentle fall from the late teens onwards reflects the diminishing effect of the high uptakes of radioisotopes of the alkaline earths and of lead in this period. About 60% of the equivalent dose is contributed by the low linear energy transfer (LET) component. Radionuclides in food make the largest contribution to equivalent doses to RBM and much the largest contribution to the absorbed dose from high LET radiation (mainly alpha particles).

  10. Doses to the red bone marrow of young people and adults from radiation of natural origin

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, G M [Childhood Cancer Research Group, University of Oxford, Richards Building, Old Road Campus, Headington, Oxford OX3 7LG (United Kingdom); Fell, T P, E-mail: Gerald.Kendall@ccrg.ox.ac.uk [Health Protection Agency, CRCE, Chilton, Didcot OX11 0RQ, Oxon (United Kingdom)

    2011-09-01

    Natural radiation sources comprise cosmic rays, terrestrial gamma rays, radionuclides in food and inhaled isotopes of radon with their decay products. These deliver doses to all organs and tissues including red bone marrow (RBM), the tissue in which leukaemia is thought to originate. In this paper we calculate the age-dependent annual RBM doses from natural radiation sources to young people and to adults at average levels of exposure in the UK. The contributions to dose are generally less complex than in the case of doses to foetuses and young children where it is necessary to take into account transfer of radionuclides across the placenta, intakes in mother's milk and changes in gut uptake in young infants. However, there is high uptake of alkaline earths and of similar elements in the developing skeleton and this significantly affects the doses from radioisotopes of these elements, not just in the teens and twenties but through into the fifth decade of life. The total equivalent dose to the RBM from all natural sources of radiation at age 15 years is calculated to be about 1200 {mu}Sv a year at average UK levels, falling to rather less than 1100 {mu}Sv per year in later life; the gentle fall from the late teens onwards reflects the diminishing effect of the high uptakes of radioisotopes of the alkaline earths and of lead in this period. About 60% of the equivalent dose is contributed by the low linear energy transfer (LET) component. Radionuclides in food make the largest contribution to equivalent doses to RBM and much the largest contribution to the absorbed dose from high LET radiation (mainly alpha particles).

  11. SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, S; Kushima, N; Katsura, K; Tanabe, S; Hayakawa, T; Sakai, H; Yamada, T; Takahashi, H; Abe, E; Wada, S; Aoyama, H [Niigata University, Niigata (Japan)

    2016-06-15

    Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

  12. Beliefs Contributing to HIV-related Stigma in African and Afro-Caribbean Communities in the Netherlands

    NARCIS (Netherlands)

    Stutterheim, S.E.; Bos, A.E.R.; Kesteren, van N.M.C.; Shiripinda, I.; Pryor, J.B.; Bruin, de M.; Schaalma, H.P.

    2012-01-01

    Thirty years after the first diagnosis, people living with HIV (PLWH) around the world continue to report stigmatizing experiences. In this study, beliefs contributing to HIV-related stigma in African and Afro-Caribbean diaspora communities and their cultural context were explored through

  13. Contribution to optimization of individual doses of workers in shipment of generator technetium-99m

    International Nuclear Information System (INIS)

    Fonseca, Lizandra Pereira de Souza

    2010-01-01

    The Instituto de Pesquisas Energeticas e Nucleares, IPEN, radiopharmaceuticals research and produce that are distributed throughout Brazil, currently the radiopharmaceutical with the largest number of packaged shipped per year and with the highest total activity is the 99m technetium generator. To reduce individual doses for workers involved in the production of radiopharmaceuticals was performed a study of radiological protection optimization in the shipment process of technetium generator, using the techniques: differential cost-benefit analysis, integral cost-benefit analysis, multi-attribute utility analysis and multi-criteria outranking analysis. With changes in the configuration of packed for generator dispatch and with the acquirement of a mat transporter it was possible establish 4 protection options. The attributes considered were the protection cost, collective dose, individual dose and physical effort by worker to move the package without the mat. To assess the robustness of analytical solutions found with the techniques used in the optimization we performed a sensitivity study and found that option 3 is more robust than option 1, which is no longer the analytical solution with an increase of R$ 20.000,00 the cost of protection. (author)

  14. A novel dose uncertainty model and its application for dose verification

    International Nuclear Information System (INIS)

    Jin Hosang; Chung Heetaek; Liu Chihray; Palta, Jatinder; Suh, Tae-Suk; Kim, Siyong

    2005-01-01

    Based on statistical approach, a novel dose uncertainty model was introduced considering both nonspatial and spatial dose deviations. Non-space-oriented uncertainty is mainly caused by dosimetric uncertainties, and space-oriented dose uncertainty is the uncertainty caused by all spatial displacements. Assuming these two parts are independent, dose difference between measurement and calculation is a linear combination of nonspatial and spatial dose uncertainties. Two assumptions were made: (1) the relative standard deviation of nonspatial dose uncertainty is inversely proportional to the dose standard deviation σ, and (2) the spatial dose uncertainty is proportional to the gradient of dose. The total dose uncertainty is a quadratic sum of the nonspatial and spatial uncertainties. The uncertainty model provides the tolerance dose bound for comparison between calculation and measurement. In the statistical uncertainty model based on a Gaussian distribution, a confidence level of 3σ theoretically confines 99.74% of measurements within the bound. By setting the confidence limit, the tolerance bound for dose comparison can be made analogous to that of existing dose comparison methods (e.g., a composite distribution analysis, a γ test, a χ evaluation, and a normalized agreement test method). However, the model considers the inherent dose uncertainty characteristics of the test points by taking into account the space-specific history of dose accumulation, while the previous methods apply a single tolerance criterion to the points, although dose uncertainty at each point is significantly different from others. Three types of one-dimensional test dose distributions (a single large field, a composite flat field made by two identical beams, and three-beam intensity-modulated fields) were made to verify the robustness of the model. For each test distribution, the dose bound predicted by the uncertainty model was compared with simulated measurements. The simulated

  15. Response of pig skin to fractionated radiation doses

    International Nuclear Information System (INIS)

    Wiernik, G.; Hopewell, J.W.; Patterson, T.J.S.; Young, C.M.A.; Foster, J.L.

    1977-01-01

    The individual components of a fractionated course of irradiation treatment have been considered separately. Methods of accurate measurement of individual parameters has brought to light different interpretations of the observations. Reasons are given for the necessity of having a radiobiological model which has a direct relevance to the clinical situation. Results are reported for fractionated regimes of irradiation in which the dose has been varied above and below normal tissue tolerance which has been equated with clinical skin necrosis. The components of the acute skin reaction, erythema, pigmentation and desquamation have been analysed separately and their contribution as a method of measurement assessed. Initially, the range of numerical scores attributed to erythema did not reach the scores attributed to necrosis but we now believe that radiation damage expressed as erythema can move directly into necrosis without passing through desquamation. Desquamation, on the other hand, only became a useful parameter at higher dose levels; it has also been shown to be a component associated with skin breakdown. Pigmentation showed no dose response at the dose levels employed in our experiments and it is our belief that this is due to this system being fully saturated under these circumstances. Measurement of the late radiation reaction in the skin has been considered in detail and our results have been expressed by comparing the relative lengths of irradiated and control fields in the same pig. From these findings iso-effect graphs have been constructed and time and fractionation factors have been derived. (author)

  16. Transuranium element toxicity: dose-response relationships at low exposure levels. Summary and speculative interpretation relative to exposure limits

    International Nuclear Information System (INIS)

    Thompson, R.C.

    1975-01-01

    A summary is given of information on transuranium element toxicity and the correlation of this information with current established exposure limits. It is difficult to calculate a biologically relevant radiation dose from deposited plutonium; it is exposure that must be controlled in order to prevent biological effect, and if the relationship between exposure and effect is known, then radiation dose is of no concern. There are extensive data on the effects of plutonium in bone. Results of studies at the University of Utah indicate that plutonium in beagles may be as much as ten times more toxic than radium. It has been suggested that this toxicity ratio may be even higher in man than in the beagle dog because of differences in surface-to-volume ratios and differences in the rate of burial of surface-deposited plutonium. The present capabilities for extrapolating dose-effect relationships seem to be limited to the setting of upper limits, based on assumptions of linearity and considerations related to natural background

  17. The relative contribution of patient, provider and organizational influences to the appropriate diagnosis and management of diabetes mellitus.

    Science.gov (United States)

    Marceau, Lisa; McKinlay, John; Shackelton, Rebecca; Link, Carol

    2011-12-01

    To estimate the relative contribution of patient attributes, provider characteristics and organizational features of the doctors' workplace to the diagnosis and management of diabetes. In a factorial experimental design doctors (n = 192) viewed clinically authentic vignettes of 'patients' presenting with identical signs and symptoms. Doctor subjects were primary care doctors stratified according to gender and level of experience. During an in-person interview scheduled between real patients, doctors were asked how they would diagnosis and manage the vignette 'patients' in clinical practice. This study considered the relative contribution of patient, doctor and organizational factors. Taken together patient attributes explained only 4.4% of the variability in diabetes diagnosis. Doctor factors explained only 2.0%. The vast majority of the explained variance in diabetes diagnosis was due to organizational factors (14.3%). Relative contributions combined (patient, provider, organizational factors) explained only 20% of the total variance. Attempts to reduce health care variations usually focus on the education/activation of patients, or increased training of doctors. Our findings suggest that shifting quality improvement efforts to the area which contributes most to the creation and amplification of variations (organizational influences) may produce better results in terms of reduced variations in health care associated with diabetes. © 2010 Blackwell Publishing Ltd.

  18. Superficial dose evaluation of four dose calculation algorithms

    Science.gov (United States)

    Cao, Ying; Yang, Xiaoyu; Yang, Zhen; Qiu, Xiaoping; Lv, Zhiping; Lei, Mingjun; Liu, Gui; Zhang, Zijian; Hu, Yongmei

    2017-08-01

    Accurate superficial dose calculation is of major importance because of the skin toxicity in radiotherapy, especially within the initial 2 mm depth being considered more clinically relevant. The aim of this study is to evaluate superficial dose calculation accuracy of four commonly used algorithms in commercially available treatment planning systems (TPS) by Monte Carlo (MC) simulation and film measurements. The superficial dose in a simple geometrical phantom with size of 30 cm×30 cm×30 cm was calculated by PBC (Pencil Beam Convolution), AAA (Analytical Anisotropic Algorithm), AXB (Acuros XB) in Eclipse system and CCC (Collapsed Cone Convolution) in Raystation system under the conditions of source to surface distance (SSD) of 100 cm and field size (FS) of 10×10 cm2. EGSnrc (BEAMnrc/DOSXYZnrc) program was performed to simulate the central axis dose distribution of Varian Trilogy accelerator, combined with measurements of superficial dose distribution by an extrapolation method of multilayer radiochromic films, to estimate the dose calculation accuracy of four algorithms in the superficial region which was recommended in detail by the ICRU (International Commission on Radiation Units and Measurement) and the ICRP (International Commission on Radiological Protection). In superficial region, good agreement was achieved between MC simulation and film extrapolation method, with the mean differences less than 1%, 2% and 5% for 0°, 30° and 60°, respectively. The relative skin dose errors were 0.84%, 1.88% and 3.90%; the mean dose discrepancies (0°, 30° and 60°) between each of four algorithms and MC simulation were (2.41±1.55%, 3.11±2.40%, and 1.53±1.05%), (3.09±3.00%, 3.10±3.01%, and 3.77±3.59%), (3.16±1.50%, 8.70±2.84%, and 18.20±4.10%) and (14.45±4.66%, 10.74±4.54%, and 3.34±3.26%) for AXB, CCC, AAA and PBC respectively. Monte Carlo simulation verified the feasibility of the superficial dose measurements by multilayer Gafchromic films. And the rank

  19. Parotid gland tumors: A comparison of postoperative radiotherapy techniques using three dimensional (3D) dose distributions and dose-volume histograms (DVHs)

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Fontenla, Doracy P.; Tyerech, Sangeeta K.; Boselli, Lucia R.; Beitler, Jonathan J.

    1998-01-01

    Purpose: To compare different treatment techniques for unilateral treatment of parotid gland tumors. Methods and Materials: The CT-scans of a representative parotid patient were used. The field size was 9 x 11 cm, the separation was 15.5 cm, and the prescription depth was 4.5 cm. Using 3D dose distributions, tissue inhomogeneity corrections, scatter integration (for photons) and pencil beam (for electrons) algorithms and dose-volume histogram (DVH), nine treatment techniques were compared. [1] unilateral 6 MV photons [2] unilateral 12 MeV electrons [3] unilateral 16 MeV electrons [4] an ipsilateral wedge pair technique using 6 MV photons [5] a 3-field AP (wedged), PA (wedged) and lateral portal technique using 6 MV photons [6] a mixed beam technique using 6 MV photons and 12 MeV electrons (1:4 weighting) [7] a mixed beam technique using 6 MV photons and 16 MeV electrons (1:4 weighting) [8] a mixed beam technique using 18 MV photons and 20 MeV electrons (2:3 weighting) [9] a mixed beam technique using 18 MV photons and 20 MeV electrons (1:1 weighting). Results: Using dose-volume histograms to evaluate the dose to the contralateral parotid gland, the percentage of contralateral parotid volume receiving ≥ 30% of the prescribed dose was 100% for techniques [1], [8] and [9], and < 5% for techniques [2] through [7]. Evaluating the 'hottest' 5 cc of the ipsilateral mandible and temporal lobes, the hot spots were: 152% and 150% for technique [2], 132% and 130% for technique [6]. Comparing the exit doses, techniques [1], [8] and [9] contributed to ≥ 50% of the prescribed dose to the contralateral mandible and the temporal lobes. Only techniques [2] and [6] kept the highest point doses to both the brain stem and the spinal cord below 50% of the prescribed dose. Conclusion: The single photon lateral field [1] and the mixed electron-photon beams [8] and [9] are not recommended treatment techniques for unilateral parotid irradiation because of high doses delivered to the

  20. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    implants with a weight of 1393 g the maximum dose rate of 6.5276 kGy /h, the minimum dose rate of 3.5684 kGy /h and the dose uniformity of 1 83 were determined. Then, based on the minimum dose rate irradiation times were calculated for different doses to evaluate in the microbial decontamination of food (3, 5, 8 and 12 kGy) and the sterilization of medical material by radiation (15, 20, 25 and 40 kGy), corroborating the applied doses with routine dosimeters of ethanol chlorobenzene (1-100 kGy) and perspex network 4034 (5-50 kGy). Other routine dosimeters used in different applications according to the doses range are Gafchromic Hd (40-400 Gray) for induced mutation by radiation and the development of new varieties of plants, the sterile insect technique to eradicate pests, quarantine treatment to solve plant health problems. Ambar Perspex 3042 C (3-15 kGy) for microbial decontamination of dried foods, spices, aromatic herbs, medicinal plants, etc. GEX B-3000 (1-140 kGy) and FWT (0.5-200 kGy) for sterilization of medical and pharmaceutical material, cosmetics, biological tissues, etc. The minimum dose rate allowing to calculate the irradiation times to apply the desired dose for the research or industrial processes, taking into account the density and geometry of product. Is notorious the difference in dose uniformity in food (1, 16) and medical material (1, 83) due to the geometry and relative density of the products within the irradiation cylinder. (author)

  1. Dose profile in computed tomography chest scan; Perfil de dose em varredura de torax em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno B., E-mail: bbo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais; Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil); Alonso, Thessa C.; Silva, Teogenes A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2010-07-01

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58{+-}5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  2. Ionizing radiation population doses at Sao Paulo city, Brazil: open-pit gamma dose measurement

    International Nuclear Information System (INIS)

    Oliveira, Raimundo Enoch Rodrigues

    2001-01-01

    The effects of ionizing radiation to the human beings are well known for high and intermediate doses. As far as low level) radiation doses are concerned, there is no consensus. In order to get a better understanding of such effects it is necessary to assess the low doses with better accuracy. In this work, it was made an estimate of the annual ambient dose equivalent (H * (10)) to which the people are exposed in the city of Sao Paulo. Until now there are no data about it available in the literature. For the purpose of this evaluation, a map with various routes covering the largest and more representative area of the city was designed. The choice of points for data collection was made taking into account mainly the occupancy of the region. A portable gamma spectrometry system was used. It furnishes the rate of H * (10) and the measured gamma spectrum (in the range from 50 to 1670 keV) in the place of interest. The measurements were performed in a short time interval, since the gamma radiation arrives from a great extent of soil. Each measurement was done 1 m above the soil during 300 s. The rates of H * (10) varied from 33.1 to 152.3 nSv.h -1 , net values, obtained after subtraction of the cosmic rays contribution. The standard deviation was 22 n Sv.h -1 for an average for the city of Sao Paulo of 96.1(24) nSv.h -1 . In addition, average values of H * (10) rates for the city Health Divisions were calculated. Those values are not statistically equivalent and the whole set of data could not be treated as one, as the statistical Student test indicated a non homogeneity of the group of data. Hence it is necessary the accomplishment of a more detailed survey in order to verify the origin of the discrepancy. The mean value of H * (10) rate obtained for the city of Sao Paulo as converted to effective dose. in order to be compared with other places results It could be noticed that the annual average of effective dose for the city of Sao Paulo, 0.522(13) mSv, is superior to

  3. Urochloa ruziziensis responses to sources and doses of urea

    Directory of Open Access Journals (Sweden)

    João E. S. Lima

    2016-05-01

    Full Text Available ABSTRACT The use of products that promote reduction of nitrogen (N losses from the urea fertilizer can contribute to increasing its use efficiency in forage grasses. This study aimed to evaluate the effects of N sources and doses on the growth of Urochloa ruziziensis. The experiment was carried out in the growing season of 2007/2008 in Santo Antônio de Goiás-GO, in a Brazilian Oxisol. A completely randomized block was used, with four replicates in a factorial scheme, corresponding to two N sources (conventional urea and urea with urease inhibitor and five N doses (0, 50, 100, 200 and 300 kg ha-1, divided into equal applications in five periods (Nov 14 to Dec 13, Dec 14 to Jan 12, Jan 13 to Feb 11 - rainy season, Mar 24 to Apr 22 and Jul 10 to Aug 08 - dry season. The effects of the treatments were evaluated for: shoot dry matter, tiller density, total N content in the leaves and relative chlorophyll content. N fertilizer sources did not affect the evaluated variables; however, N fertilization allowed linear increases in all variables with higher values during the rainy period. The relative chlorophyll content in U. ruziziensis had positive correlation with its dry matter productivity.

  4. Collective dose estimates by the marine food pathway from liquid radioactive wastes dumped in the Sea of Japan

    International Nuclear Information System (INIS)

    Togawa, O.; Povinec, P.P.; Pettersson, H.B.L.

    1999-01-01

    IAEA-MEL has been engaged in an assessment programme related to radioactive waste dumping by the former USSR and other countries in the western North Pacific Ocean and its marginal seas. This paper focuses on the Sea of Japan and on estimation of collective doses from liquid radioactive wastes. The results from the Japanese-Korean-Russian joint expeditions are summarized, and collective doses for the Japanese population by the marine food pathway are estimated from liquid radioactive wastes dumped in the Sea of Japan and compared with those from global fallout and natural radionuclides. The collective effective dose equivalents by the annual intake of marine products caught in each year show a maximum a few years after the disposals. The total dose from all radionuclides reaches a maximum of 0.8 man Sv in 1990. Approximately 90% of the dose derives from 137Cs, most of which is due to consumption of fish. The total dose from liquid radioactive wastes is approximately 5% of that from global fallout, the contribution of which is below 0.1% of that of natural 210Po

  5. Field size and dose distribution of electron beam

    International Nuclear Information System (INIS)

    Kang, Wee Saing

    1980-01-01

    The author concerns some relations between the field size and dose distribution of electron beams. The doses of electron beams are measured by either an ion chamber with an electrometer or by film for dosimetry. We analyzes qualitatively some relations; the energy of incident electron beams and depths of maximum dose, field sizes of electron beams and depth of maximum dose, field size and scatter factor, electron energy and scatter factor, collimator shape and scatter factor, electron energy and surface dose, field size and surface dose, field size and central axis depth dose, and field size and practical range. He meets with some results. They are that the field size of electron beam has influence on the depth of maximum dose, scatter factor, surface dose and central axis depth dose, scatter factor depends on the field size and energy of electron beam, and the shape of the collimator, and the depth of maximum dose and the surface dose depend on the energy of electron beam, but the practical range of electron beam is independent of field size

  6. On the relative contribution of the paretic leg to the control of posture after stroke.

    NARCIS (Netherlands)

    Roerdink, M.; Geurts, A.C.H.; Haart, M. de; Beek, P.J.

    2009-01-01

    BACKGROUND: Reduced postural steadiness and asymmetry of weight bearing are characteristic for posture after stroke. OBJECTIVE: To examine the relative contribution of each leg to postural control in a cohort of 33 stroke patients at 5 stages during 3 months of inpatient rehabilitation, while taking

  7. On the relative contribution of the paretic leg to the control of posture after stroke

    NARCIS (Netherlands)

    Roerdink, M.; Geurts, A.C.; de Haart, M.; Beek, P.J.

    2009-01-01

    Background: Reduced postural steadiness and asymmetry of weight bearing are characteristic for posture after stroke. Objective: To examine the relative contribution of each leg to postural control in a cohort of 33 stroke patients at 5 stages during 3 months of inpatient rehabilitation, while taking

  8. In vivo dosimetry with thermoluminescent dosimeters in radiotherapy: entrance and exit doses

    International Nuclear Information System (INIS)

    Alves, C.; Lopes, M.C.

    2000-01-01

    In vivo dosimetry, by entrance and exit dose measurements, is a vital part of a radiotherapy quality assurance program. The uncertainty associated with dose delivery is internationally accepted to be within 5% or inferior depending on the tumor pathology. Thermoluminescent dosimetry is one of the dosimetric techniques used to verify the agreement between delivered and prescribed doses. Nevertheless, it requires a very accurate calibration methodology. We have used LiF chips (4.5 mm diameter and 0.8 mm thick) calibrated towards a PTW ionization chamber of 0.3 cc, in three photon energies: Co-60, 4 and 6 MeV. The TLD reader used was a Rialto 688 from NE Technology and the annealing oven the Eurotherm type 815. The calibration methodology relies on the experimental determination of individual correction factors and on a correction factor derived from a control group of dosimeters. The exit and entrance dose measurements are performed in quite different situations. To be able to achieve those two quantities with TLD, these should be independently calibrated according to the measurement conditions. Alternatively, we can use a single calibration, in entrance dose, and convert the result to the exit dose value by introducing some correction factors. These corrections are related to the different measurement depths and to the different backscattering contributions. We have proved that within an acceptable error we can perform a single calibration and adopt the correction factors which are energy and field size dependent. (author)

  9. Radiation Therapy to the Plexus Brachialis in Breast Cancer Patients: Analysis of Paresthesia in Relation to Dose and Volume.

    Science.gov (United States)

    Lundstedt, Dan; Gustafsson, Magnus; Steineck, Gunnar; Sundberg, Agnetha; Wilderäng, Ulrica; Holmberg, Erik; Johansson, Karl-Axel; Karlsson, Per

    2015-06-01

    To identify volume and dose predictors of paresthesia after irradiation of the brachial plexus among women treated for breast cancer. The women had breast surgery with axillary dissection, followed by radiation therapy with (n=192) or without irradiation (n=509) of the supraclavicular lymph nodes (SCLNs). The breast area was treated to 50 Gy in 2.0-Gy fractions, and 192 of the women also had 46 to 50 Gy to the SCLNs. We delineated the brachial plexus on 3-dimensional dose-planning computerized tomography. Three to eight years after radiation therapy the women answered a questionnaire. Irradiated volumes and doses were calculated and related to the occurrence of paresthesia in the hand. After treatment with axillary dissection with radiation therapy to the SCLNs 20% of the women reported paresthesia, compared with 13% after axillary dissection without radiation therapy, resulting in a relative risk (RR) of 1.47 (95% confidence interval [CI] 1.02-2.11). Paresthesia was reported by 25% after radiation therapy to the SCLNs with a V40 Gy ≥ 13.5 cm(3), compared with 13% without radiation therapy, RR 1.83 (95% CI 1.13-2.95). Women having a maximum dose to the brachial plexus of ≥55.0 Gy had a 25% occurrence of paresthesia, with RR 1.86 (95% CI 0.68-5.07, not significant). Our results indicate that there is a correlation between larger irradiated volumes of the brachial plexus and an increased risk of reported paresthesia among women treated for breast cancer. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The mean active bone marrow dose to the adult population of the United States from diagnostic radiology

    International Nuclear Information System (INIS)

    Shleien, B.; Tucker, T.T.; Johnson, D.W.

    1977-01-01

    Estimates, based on an empirical model and computer program, have been calculated and are presented on the mean active bone marrow dose to adults from diagnostic radiography, fluoroscopy, and dental radiography as practiced in the United States in 1970. The annual per capita mean active bone marrow dose in 1970 to adults from the above practices is estimated to be 103 mrad; 77 percent, 20 percent, and 3 percent from radiographic, fluoroscopic and dental examinations respectively. Examinations of the upper and lower abdomen contribute approximately 39 percent each to the total mean active bone marrow dose for adults; those of the pelvis 4 percent; the thorax 12 percent; and head and neck examinations (including dental) contribute about 6 percent. The per capita mean active bone marrow dose for various age groups is discussed. Contributions to the dose within a given age group from different examinations indicate that in the 15-34 year old age group Lumbar and Lumbosacral Spine examinations contribute most to the mean active bone marrow dose. Thereafter Upper G I Series and Barium Enemas are the highest contributors. Comparisons are made with results of the 1964 U.S. X-ray survey and similar surveys from other nations

  11. Estimates of dose to systematic organs and GI tract based on data from miniature swine orally intubated with a single dose of Am-241 citrate

    International Nuclear Information System (INIS)

    Bernard, S.R.; Nestor, C.W. Jr.; Eisele, G.R.; Eckerman, K.F.

    1982-01-01

    A model is presented for the internal radiation dose to the small intestine wall of miniature swine given Americium 241 citrate by oral intubation. The model incorporates the uptake of the Am-241 by the intestinal wall. About equal contributions of dose to the small intestine were observed from the intestinal contents and the wall itself

  12. Patient dose during radiological examination in the follow-up of bariatric surgery

    International Nuclear Information System (INIS)

    Moro, L.; Cazzani, C.; Tomarchio, O.; Morone, G.; Catona, A.; Fantinato, D.

    2007-01-01

    A patient dose survey was carried out measuring the kerma-area product (KAP) values during radiological evaluation in the follow-up of bariatric surgery. The procedures were performed by three radiologists to adjust laparoscopic gastric bands and to detect postoperative complications after Roux-en-Y gastric bypass procedures to treat morbid obesity. Total fluoroscopy time, exposure factors and the overall contribution of fluoroscopy to the accumulated KAP value were recorded. The median KAP values were used to estimate organ doses and effective dose to a standard patient; the radiation risk associated with the procedures was also evaluated. The doses were smaller for one of the three radiologists, owing to a more appropriate beam collimation and a reduction of the screening time. The KAP values ranged from 1.6 to 7.1 Gy cm 2 for the laparoscopic adjustable gastric banding management, and from 3.0 and 8.3 Gy cm 2 for the radiological examinations after gastric bypass. As a whole, the effective doses associated to these procedures were between 0.5 and 2.7 mSv. The organs receiving the highest doses were not only breast, stomach, pancreas and liver, but also lungs, owing to of their high radiosensitivity, significantly contributed to the effective dose. (authors)

  13. 210Po and 210Pb levels in mussels and fish from Slovenian market and the related dose assessment

    International Nuclear Information System (INIS)

    Planinšek, Petra; Smodiš, Borut; Benedik, Ljudmila

    2013-01-01

    Polonium-210 (t 1/2 = 138 d) is a decay product of uranium-radium decay chain and consequently widely spread in the environment. It enters organisms through direct uptake, ingestion or inhalation. It is a pure alpha emitter and its radiotoxicity is connected with the fact that emits alpha particles with relatively high energy of about 5.3 MeV. It is concentrated in the soft tissues such as mussel, liver and others, where significantly contributes to the internal dose. Beta emitter lead-210 (t 1/2 = 22.17 years) is the second highest radiotoxic radionuclide from uranium-238 decay chain and decays, through bismuth- 210 (t 1/2 = 5.01 d) into 210 Po. Therefore it is necessary to determine the 21P o in foods, especially in seafood, because of its accumulation capacity. 210 Po and 210 Pb were determined in mussels (Mytilus galloprovincialis) and fish (salmon, trout) from Slovenia market. Mussels were bought on the local market as well as from domestic producers. Fish of Slovenian origin were bought on the local market. Samples were freeze dried, homogenized and assayed for 210 Po and 210 Pb. First, radiochemical separation was performed, followed by alpha particle spectrometric measurement of 210 Po and beta counting of 210 Pb on a low background gas-flow proportional counter. The results obtained show that the activity concentrations of 210 Po in mussels varied from 0.9 to 191 Bq/kg of fresh mass and for fish from 0.3 to 2.12 Bq/kg of fresh mass, while for 210 Pb they varied from 1.5 to 6.9 Bq/k of fresh mass for mussels and in fish samples the activity concentrations were less than 1.9 Bq/kg of fresh mass. Combined annual ingestion doses due to 210 Po and 210 Pb for mussels and fish from the Slovenian market is assessed. (author)

  14. Reassessment of the potential radiological doses for residents resettling Enewetak Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Mount, M.E.; Clegg, B.R.; Conrado, C.L.

    1980-01-01

    The purpose of this report is to refine the dose predictions, subsequent to the cleanup effort, for alternate living patterns proposed for resettlement of Enewetak Atoll. The most recent data developed from projects at Enewetak and Bikini Atolls for concentration and uptake of Cs, Sr, Pu, and Am were used in conjunction with recent dietary information and current dose models to predict annual dose rates and 30- and 50-y integral doses (dose commitments). The terrestrial food chain in the most significant exposure pathway - it contributes more than 50% of the total dose - and external gamma exposure is the second most significant pathway. Other pathways evaluated are the marine food chain, drinking water, and inhalation

  15. Survey of food radioactivity and estimation of internal dose from ingestion in China

    International Nuclear Information System (INIS)

    Zhang Jingyuan; Zhu Hongda; Han Peizhen

    1988-01-01

    In order to provide necessary bases for establishing 'Radionuclide Concentration Limits in Food stuffs', survey on radionuclide contents in Chinese food and estimation of internal dose from ingestion were carried out with the cooperation of 30 radiation protection establishments during the period 1982-1986. Activity concentrations in 14 categories (27 kinds) of Chinese food for 22 radionuclides were determined. In the light of three principal types of Chinese diet, food samples were collected from normal radiation background areas in 14 provinces or autonomous regions and three similarly elevated natural background areas. Annual intake by ingestion and resultant committed dose equivalents to general public for 15 radionuclides in these areas were estimated. In normal background areas the total annual intake of the 15 radionuclides by the public (adlut males) is about 4.2 x 10 4 Bq, and the resultant total committed dose equivalent is about 3.43 x 10 -4 Sv, but in two elevated natural background area the public annual intake and resulting committed dose equivalents for some natural radionulides are much higher than those in normal areas, while no obvious radiocontamination was discoveried relative contribution of each food category or each radionuclide to the total are discussed

  16. Relative contributions of transient and steady state infiltration during ephemeral streamflow

    Science.gov (United States)

    Blasch, Kyle W.; Ferré, Ty P.A.; Hoffmann, John P.; Fleming, John B.

    2006-01-01

    Simulations of infiltration during three ephemeral streamflow events in a coarse‐grained alluvial channel overlying a less permeable basin‐fill layer were conducted to determine the relative contribution of transient infiltration at the onset of streamflow to cumulative infiltration for the event. Water content, temperature, and piezometric measurements from 2.5‐m vertical profiles within the alluvial sediments were used to constrain a variably saturated water flow and heat transport model. Simulated and measured transient infiltration rates at the onset of streamflow were about two to three orders of magnitude greater than steady state infiltration rates. The duration of simulated transient infiltration ranged from 1.8 to 20 hours, compared with steady state flow periods of 231 to 307 hours. Cumulative infiltration during the transient period represented 10 to 26% of the total cumulative infiltration, with an average contribution of approximately 18%. Cumulative infiltration error for the simulated streamflow events ranged from 9 to 25%. Cumulative infiltration error for typical streamflow events of about 8 hours in duration in is about 90%. This analysis indicates that when estimating total cumulative infiltration in coarse‐grained ephemeral stream channels, consideration of the transient infiltration at the onset of streamflow will improve predictions of the total volume of infiltration that may become groundwater recharge.

  17. Proxy-based reconstruction of erythemal UV doses over Estonia for 1955–2004

    Directory of Open Access Journals (Sweden)

    K. Eerme

    2006-08-01

    Full Text Available A proxy-based reconstruction of the erythemally-weighted UV doses for 1955-2004 has been performed for the Tartu-Tõravere Meteorological Station (58°16' N, 26°28' E, 70 m a.s.l. site. The pyrheliometer-measured daily sum of direct irradiance on partly cloudy and clear days, and the pyranometer-measured daily sum of global irradiance on overcast days were used as the cloudiness influence related proxies. The TOMS ozone data have been used for detecting the daily deviations from the climatic value (averaged annual cycle. In 1998–2004, the biases between the measured and reconstructed daily doses in 55.5% of the cases were within ±10% and in 83.5% of the cases within ±20%, on average. In the summer half-year these amounts were 62% and 88%, respectively. In most years the results for longer intervals did not differ significantly, if no correction was made for the daily deviations of total ozone from its climatic value. The annual and summer half-yearly erythemal doses (contributing, on average, 89% of the annual value agreed within ±2%, except for the years after major volcanic eruptions and one extremely fine weather year (2002. Using the daily relative sunshine duration as a proxy without detailed correction for atmospheric turbidity results in biases of 2–4% in the summer half-yearly dose in the years after major volcanic eruptions and a few other years of high atmospheric turbidity. The year-to-year variations of the summer half-yearly erythemal dose in 1955–2004 were found to be within 92–111% relative to their average value. Exclusion of eight extreme years reduces this range for the remaining to 95–105.5%. Due to the quasi-periodic alternation of wet and dry periods, the interval of cloudy summers 1976–1993 regularly manifests summer half-yearly erythemal dose values lower than the 1955–2004 average. Since 1996/1997 midwinters have been darker than on average.

  18. Proxy-based reconstruction of erythemal UV doses over Estonia for 1955–2004

    Directory of Open Access Journals (Sweden)

    K. Eerme

    2006-08-01

    Full Text Available A proxy-based reconstruction of the erythemally-weighted UV doses for 1955-2004 has been performed for the Tartu-Tõravere Meteorological Station (58°16' N, 26°28' E, 70 m a.s.l. site. The pyrheliometer-measured daily sum of direct irradiance on partly cloudy and clear days, and the pyranometer-measured daily sum of global irradiance on overcast days were used as the cloudiness influence related proxies. The TOMS ozone data have been used for detecting the daily deviations from the climatic value (averaged annual cycle. In 1998–2004, the biases between the measured and reconstructed daily doses in 55.5% of the cases were within ±10% and in 83.5% of the cases within ±20%, on average. In the summer half-year these amounts were 62% and 88%, respectively. In most years the results for longer intervals did not differ significantly, if no correction was made for the daily deviations of total ozone from its climatic value. The annual and summer half-yearly erythemal doses (contributing, on average, 89% of the annual value agreed within ±2%, except for the years after major volcanic eruptions and one extremely fine weather year (2002. Using the daily relative sunshine duration as a proxy without detailed correction for atmospheric turbidity results in biases of 2–4% in the summer half-yearly dose in the years after major volcanic eruptions and a few other years of high atmospheric turbidity. The year-to-year variations of the summer half-yearly erythemal dose in 1955–2004 were found to be within 92–111% relative to their average value. Exclusion of eight extreme years reduces this range for the remaining to 95–105.5%. Due to the quasi-periodic alternation of wet and dry periods, the interval of cloudy summers 1976–1993 regularly manifests summer half-yearly erythemal dose values lower than the 1955–2004 average. Since 1996/1997 midwinters have been darker than on average.

  19. On the relative contribution of the paretic leg to the control of posture after stroke

    NARCIS (Netherlands)

    Roerdink, Melvyn; Geurts, Alexander C. H.; de Haart, Mirjam; Beek, Peter J.

    2009-01-01

    Reduced postural steadiness and asymmetry of weight bearing are characteristic for posture after stroke. To examine the relative contribution of each leg to postural control in a cohort of 33 stroke patients at 5 stages during 3 months of inpatient rehabilitation, while taking clinical scores of

  20. Study on fine quartz pre-dose techniques

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Wang Weida; Xia Junding

    1996-01-01

    When using the pre-dose technique in ceramic dating, it is essential to add a calibration dose and to eliminate the background dose. For doing this measurement the sample requires multiple activation following multiple administration of a test dose to induce simulated 'ancient' thermoluminescence (TL). However, the procedures introduce many factors that are difficultly corrected. The authors compare existing two kinds of measurement procedures and proposes a new procedure involving single activation following a single test dose administration. An experiment using the single activation procedure is carried out with natural fine quartz where the results obtained exhibit only 0.07 relative error. It appears that this new procedure increases the precision of the ancient TL measurement by about 0.04 and 0.11 over those of existing two kinds of procedures. In addition this method can give realistic values in TL dating for relatively 'young' samples aged tens to hundreds of years where the standard high temperature TL method is relatively insensitive