WorldWideScience

Sample records for relative cardiac output

  1. Cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Andreja Möller Petrun

    2014-02-01

    Full Text Available In recent years, developments in the measuring of cardiac output and other haemodynamic variables are focused on the so-called minimally invasive methods. The aim of these methods is to simplify the management of high-risk and haemodynamically unstable patients. Due to the need of invasive approach and the possibility of serious complications the use of pulmonary artery catheter has decreased. This article describes the methods for measuring cardiac output, which are based on volume measurement (Fick method, indicator dilution method, pulse wave analysis, Doppler effect, and electrical bioimpedance.

  2. Cardiac output during exercise

    DEFF Research Database (Denmark)

    Siebenmann, C; Rasmussen, P.; Sørensen, H.

    2015-01-01

    Several techniques assessing cardiac output (Q) during exercise are available. The extent to which the measurements obtained from each respective technique compares to one another, however, is unclear. We quantified Q simultaneously using four methods: the Fick method with blood obtained from...... the right atrium (Q(Fick-M)), Innocor (inert gas rebreathing; Q(Inn)), Physioflow (impedance cardiography; Q(Phys)), and Nexfin (pulse contour analysis; Q(Pulse)) in 12 male subjects during incremental cycling exercise to exhaustion in normoxia and hypoxia (FiO2  = 12%). While all four methods reported...... a progressive increase in Q with exercise intensity, the slopes of the Q/oxygen uptake (VO2) relationship differed by up to 50% between methods in both normoxia [4.9 ± 0.3, 3.9 ± 0.2, 6.0 ± 0.4, 4.8 ± 0.2 L/min per L/min (mean ± SE) for Q(Fick-M), Q(Inn), QP hys and Q(Pulse), respectively; P = 0...

  3. Comparing Methods for Cardiac Output

    DEFF Research Database (Denmark)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F

    2018-01-01

    of the left ventricular outflow tract. METHODS: The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed...... tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation......, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias...

  4. Comparison of cardiac output measurement techniques

    DEFF Research Database (Denmark)

    Espersen, K; Jensen, E W; Rosenborg, D

    1995-01-01

    Simultaneously measured cardiac output obtained by thermodilution (TD), transcutaneous suprasternal ultrasonic Doppler (DOP), CO2-rebreathing (CR) and the direct Fick method (FI) were compared in eleven healthy subjects in a supine position (SU), a sitting position (SI), and during sitting exercise...

  5. Cardiac output measurement instruments controlled by microprocessors

    International Nuclear Information System (INIS)

    Spector, M.; Barritault, L.; Boeri, C.; Fauchet, M.; Gambini, D.; Vernejoul, P. de

    The nuclear medicine and biophysics laboratory of the Necker-Enfants malades University Hospital Centre has built a microprocessor controlled Cardiac flowmetre. The principle of the cardiac output measurement from a radiocardiogram is well established. After injection of a radioactive indicator upstream from the heart cavities the dilution curve is obtained by the use of a gamma-ray precordial detector. This curve normally displays two peaks due to passage of the indicator into the right and left sides of the heart respectively. The output is then obtained from the stewart Hamilton principle once recirculation is eliminated. The graphic method used for the calculation however is long and tedious. The decreasing fraction of the dilution curve is projected in logarithmic space in order to eliminate recirculation by determining the mean straight line from which the decreasing exponential is obtained. The principle of the use of microprocessors is explained (electronics, logics) [fr

  6. Relationship between cardiac output and effective renal plasma flow in patients with cardiac disease

    Energy Technology Data Exchange (ETDEWEB)

    McGriffin, D; Tauxe, W N; Lewis, C; Karp, R; Mantle, J

    1984-12-01

    The relationship between effective renal plasma flow (ERPF) and cardiac output was examined in 46 patients (22 with congestive heart failure and 24 following cardiac surgical procedures) by simultaneously measuring the global ERPF by the single-injection method and cardiac output by the thermodilution method. Of the patients in the heart-failure group, 21 also had pulmonary artery end diastolic pressure (PAEDP) recorded at the same time. ERPF and cardiac output were found to be related by the regression equations: cardiac output = 2.08 + 0.0065 ERPF (r, 080), with a SE of estimate of 0.81 l/min. ERPF and PAEDP were related by the regression equation: PAEDP = 42.02 - 0.0675 ERPF (r, 0.86), with a SE of estimate of 5.5 mm Hg. ERPF may be a useful noninvasive method of estimating cardiac output if it is known that no intrinsic kidney disease is present, and if the error of 0.81 l/min (1 SE of estimate) is within the range of clinical usefulness. The error is principally attributable to the determination of cardiac output by the thermodilution method.

  7. Peripheral vasodilatation determines cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Bada, A A; Svendsen, J H; Secher, N H

    2012-01-01

    In dogs, manipulation of heart rate has no effect on the exercise-induced increase in cardiac output. Whether these findings apply to humans remain uncertain, because of the large differences in cardiovascular anatomy and regulation. To investigate the role of heart rate and peripheral...... arterial ATP infusion at rest. Exercise and ATP infusion increased cardiac output, leg blood flow and vascular conductance (P heart rate by up to 54 beats min(−1), cardiac output did not change in any of the three...... demonstrate that the elevated cardiac output during steady-state exercise is regulated by the increase in skeletal muscle blood flow and venous return to the heart, whereas the increase in heart rate appears to be secondary to the regulation of cardiac output....

  8. Mechanisms Regulating the Cardiac Output Response to Cyanide Infusion, a Model of Hypoxia

    Science.gov (United States)

    Liang, Chang-seng; Huckabee, William E.

    1973-01-01

    When tissue metabolic changes like those of hypoxia were induced by intra-aortic infusion of cyanide in dogs, cardiac output began to increase after 3 to 5 min, reached a peak (220% of the control value) at 15 min, and returned to control in 40 min. This pattern of cardiac output rise was not altered by vagotomy with or without atropine pretreatment. However, this cardiac output response could be differentiated into three phases by pretreating the animals with agents that block specific activities of the sympatho-adrenal system. First, ganglionic blockade produced by mecamylamine or sympathetic nerve blockade by bretylium abolished the middle phase of the cardiac output seen in the untreated animal, but early and late phases still could be discerned. Second, beta-adrenergic receptor blockade produced by propranolol shortened the total duration of the cardiac output rise by abolishing the late phase. Third, when given together, propranolol and mecamylamine (or bretylium) prevented most of the cardiac output rise that follows the early phase. When cyanide was given to splenectomized dogs, the duration of the cardiac output response was not shortened, but the response became biphasic, resembling that seen after chemical sympathectomy. A similar biphasic response of the cardiac output also resulted from splenic denervation; sham operation or nephrectomy had no effect on the monophasic pattern of the normal response. Splenic venous blood obtained from cyanide-treated dogs, when infused intraportally, caused an increase in cardiac output in recipient dogs; similar infusion of arterial blood had no effects. These results suggest that the cardiac output response to cyanide infusion consists of three components: an early phase, related neither to the autonomic nervous system nor to circulating catecholamines; a middle phase, caused by a nonadrenergic humoral substance released from the spleen by sympathetic stimulation; and a late phase, dependent upon adrenergic receptors

  9. EVALUATION OF CONTINUOUS THERMODILUTION METHOD FOR CARDIAC OUTPUT MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Roman Parežnik

    2001-12-01

    Full Text Available Background. Continuous monitoring of haemodynamic variables is often necessary for detection of rapid changes in critically ill patients. In our patients recently introduced continuous thermodilution technique (CTD for cardiac output measurement was compared to bolus thermodilution technique (BTD which is a »golden standard« method for cardiac output (CO measurement in intensive care medicine.Methods. Ten critically ill patients were included in a retrospective observational study. Using CTD method cardiac output was measured continuously. BTD measurements using the same equipment were performed intermittently. The data obtained by BTD were compared to those obtained by CTD just before the BTD (CTD-before and 2–3 minutes after the BTD (CTD-after. The CO values were divided into three groups: all CO values, CO > 4.5 L/min, CO < 4.5 L/min. The bias (mean difference between values obtained by two methods, standard deviation, 95% confidence limits and relative error were calculated and the linear regression analysis was performed. t-test for pared data was used to compare the biases for CTD-before and CTD-after for an individual group. The p value of less than 0.05 was considered statistically significant.Results. A total of 60 data triplets were obtained. CTD-before ranged from 1.9 L/min to 12.6 L/min, CTD-after from 2.0 to 13.2 L/min and BTD from 1.9 to 12.0 L/min. For all CO values the bias for CTD-before was 0.13 ± 0.52 L/min (95% confidence limits 1.17–0.91 L/min, relative error was 3.52 ± 15.20%, linear regression equation was CTD-before = 0.96 × BTD + 0.01 and Pearson’s correlation coefficient was 0.95. The values for CTD-after were 0.08 ± 0.46 L/min (1.0–0.84 L/min, 2.22 ± 9.05%, CTD-after = 0.98 × BTD + 0.01 and 0.98 respectively. For all CO values there was no statistically significant difference between biases for CTD-before and CTD-after (p = 0,51. There was no statistically significant difference between biases for CTD

  10. Measurement of cardiac output in man with MR imaging

    International Nuclear Information System (INIS)

    Lipton, M.J.; Weikl, A.; Mueller, E.; Reinhardt, E.R.

    1987-01-01

    Multiecho electrocardiogram-triggered imaging sequences were obtained in 15 patients to measure aortic blood flow velocity in a 6-cm thick section. The aortic area was calculated from MR images; cardiac output was calculated as the product of velocity and area and was expressed in liters per minute. MR imaging results were compared with measurements obtained by cardiac catheterization and thermodilution. A good correlation of 0.9 was found, with a slope approaching unity

  11. Measurement of Cardiac Output by Constant Injection of Radioactive Xenon

    Energy Technology Data Exchange (ETDEWEB)

    Kishon, Y.; Avasthey, P.; Barnett, A.; Shillingford, J. P. [MRC Cardiovascular Research Unit and Department of Medicine, Royal Postgraduate Medical School, Hammersmith Hospital, London (United Kingdom)

    1971-02-15

    The method of determining cardiac output by the injection of {sup 133}Xe solution has been initially tested in a suitable hydrodynamic model, simulating the cardiovascular system. The indicator was infused in a constant rate into a ''pre-ventricular'' site through a fine polyethylene tubing, and samples were taken from a ''post-ventricular'' site through similar tubing. Specific activity was determined with the use of a universal well-type scintillation counter and output values were derived from the dilutional factor of the specific activity and the rate of the infusion. Good correlation with direct output measurements were demonstrated over a wide range of outputs, stroke volumes and end-diastolic volumes. The method remained valid when either the ''pre-ventricular'' or the ''post-ventricular'' valve was made incompetent. The method was then evaluated in anaesthetized dogs and cardiac output determinations were compared with those obtained by the Fick and dye-dilution techniques. The indicator was injected into the right atrium, and samples were obtained from the pulmonary artery through similar tubings. The method was found to be reliable over a wide range of cardiac outputs (drugs- and bleeding-induced) and in the presence of severe tricuspid incompetence (performed by a valvotome). Finally, the technique was used in six patients, both at rest and after exercise, and the cardiac output values were compared with those obtained by the Fick and the photoelectric-earpiece dye-dilution techniques. It is concluded that, provided the appropriate speed of injection (about 1.5 - 3.5 {mu}Ci/sec) and the time of sampling is carefully observed, good correlation between the method under investigation and other conventional methods could be shown. This method is more convenient for repeated determinations, simpler to perform and final values are obtained almost immediately. (author)

  12. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  13. Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Mortensen, Stefan; Munch, G D W

    2016-01-01

    To determine the accuracy and precision of constant infusion transpulmonary thermodilution cardiac output (CITT-Q) assessment during exercise in humans, using indocyanine green (ICG) dilution and bolus transpulmonary thermodilution (BTD) as reference methods, cardiac output (Q) was determined......: 6.1-11.1%). In conclusion, cardiac output can be precisely and accurately determined with constant infusion transpulmonary thermodilution in exercising humans....

  14. The relationship between cardiac output and dynamic cerebral autoregulation in humans.

    Science.gov (United States)

    Deegan, B M; Devine, E R; Geraghty, M C; Jones, E; Ólaighin, G; Serrador, J M

    2010-11-01

    Cerebral autoregulation adjusts cerebrovascular resistance in the face of changing perfusion pressures to maintain relatively constant flow. Results from several studies suggest that cardiac output may also play a role. We tested the hypothesis that cerebral blood flow would autoregulate independent of changes in cardiac output. Transient systemic hypotension was induced by thigh-cuff deflation in 19 healthy volunteers (7 women) in both supine and seated positions. Mean arterial pressure (Finapres), cerebral blood flow (transcranial Doppler) in the anterior (ACA) and middle cerebral artery (MCA), beat-by-beat cardiac output (echocardiography), and end-tidal Pco(2) were measured. Autoregulation was assessed using the autoregulatory index (ARI) defined by Tiecks et al. (Tiecks FP, Lam AM, Aaslid R, Newell DW. Stroke 26: 1014-1019, 1995). Cerebral autoregulation was better in the supine position in both the ACA [supine ARI: 5.0 ± 0.21 (mean ± SE), seated ARI: 3.9 ± 0.4, P = 0.01] and MCA (supine ARI: 5.0 ± 0.2, seated ARI: 3.8 ± 0.3, P = 0.004). In contrast, cardiac output responses were not different between positions and did not correlate with cerebral blood flow ARIs. In addition, women had better autoregulation in the ACA (P = 0.046), but not the MCA, despite having the same cardiac output response. These data demonstrate cardiac output does not appear to affect the dynamic cerebral autoregulatory response to sudden hypotension in healthy controls, regardless of posture. These results also highlight the importance of considering sex when studying cerebral autoregulation.

  15. Systematic review of cardiac output measurements by echocardiography vs. thermodilution

    DEFF Research Database (Denmark)

    Wetterslev, Mik; Møller-Sørensen, Hasse; Johansen, Rasmus Rothmann

    2016-01-01

    PURPOSE: Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique...... of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing...... them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. CONCLUSIONS: The majority of studies comparing...

  16. Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Hann Christopher E

    2010-11-01

    Full Text Available Abstract The application of positive end expiratory pressure (PEEP in mechanically ventilated (MV patients with acute respiratory distress syndrome (ARDS decreases cardiac output (CO. Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness. This paper examines combining models of diffusion resistance and lung mechanics, to help predict CO changes due to PEEP. The CO estimator uses an initial measurement of pulmonary shunt, and estimations of shunt changes due to PEEP to predict CO at different levels of PEEP. Inputs to the cardiac model are the PV loops from the ventilator, as well as the oxygen saturation values using known respiratory inspired oxygen content. The outputs are estimates of pulmonary shunt and CO changes due to changes in applied PEEP. Data from two published studies are used to assess and initially validate this model. The model shows the effect on oxygenation due to decreased CO and decreased shunt, resulting from increased PEEP. It concludes that there is a trade off on oxygenation parameters. More clinically importantly, the model also examines how the rate of CO drop with increased PEEP can be used as a method to determine optimal PEEP, which may be used to optimise MV therapy with respect to the gas exchange achieved, as well as accounting for the impact on the cardiovascular system and its management.

  17. Serum cortisol concentration with exploratory cut-off values do not predict the effects of hydrocortisone administration in children with low cardiac output after cardiac surgery.

    Science.gov (United States)

    Verweij, E J; Hogenbirk, Karin; Roest, Arno A W; van Brempt, Ronald; Hazekamp, Mark G; de Jonge, Evert

    2012-10-01

    Low cardiac output syndrome is common after paediatric cardiac surgery. Previous studies suggested that hydrocortisone administration may improve haemodynamic stability in case of resistant low cardiac output syndrome in critically ill children. This study was set up to test the hypothesis that the effects of hydrocortisone on haemodynamics in children with low cardiac output syndrome depend on the presence of (relative) adrenal insufficiency. A retrospective study was done on paediatric patients who received hydrocortisone when diagnosed with resistant low cardiac output syndrome after paediatric cardiac surgery in the period from 1 November 2005 to 31 December 2008. We studied the difference in effects of treatment with hydrocortisone administration between patients with adrenal insufficiency defined as an exploratory cut-off value of total cortisol of cortisol of ≥ 100 nmol/l. A total of 62 of patients were enrolled, meeting the inclusion criteria for low cardiac output syndrome. Thirty-two patients were assigned to Group 1 (cortisol concentration and those with normal baseline cortisol levels. A cortisol value using an exploratory cut-off value of 100 nmol/l for adrenal insufficiency should not be used as a criterion to treat these patients with hydrocortisone.

  18. Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Ersgård, David

    2010-01-01

    OBJECTIVES: The aim of this study was to evaluate an algorithm that estimates changes in cardiac output (CO) from right ventricular (RV) pressure waveforms derived from an implantable hemodynamic monitor (IHM) in heart failure patients. DESIGN: Twelve heart failure patients (NYHA II-III, EF 32......%) with an implantable hemodynamic monitor (Chronicle) were included in this study. Changes in cardiac output were provoked by body position change at rest (left lateral supine, horizontal supine, sitting, and standing) and a steady state bicycle exercise at 20 watts. Estimated CO derived from the IHM (CO...... was -0.39 L/min (11%). Limits of agreement were +/-1.56 L/min and relative error was 21%. CONCLUSIONS: A simple algorithm based on RV pressure wave form characteristics derived from an IHM can be used to estimate changes in CO in heart failure patients. These findings encourage further research aiming...

  19. Cardiac output and regional blood flow following trauma

    International Nuclear Information System (INIS)

    Malik, A.B.; Loegering, D.J.; Saba, T.M.; Kaplan, J.E.

    1978-01-01

    The changes in cardiac output (2), regional blood blow (2r) and regional vascular resistance, and arterial pressure were studied in rats subjected to moderate (LD0) or severe (LD50) traumatic shock. 2 and 2r were determined using microspheres at 15, 60 and 180 min posttrauma. Arterial pressure decreased in both groups at 15 min and recovered by 3 h after sublethal (LD0) trauma, while arterial pressure did not return to control levels after LD50 trauma. 2 decreased in both groups at 15 min and returned to control only in the LD0 trauma group by 3 h. Cerebral, coronary, and hepatic arterial flows and resistances were maintained in both groups. Renal, intestinal, and splenic flows decreased and resistances were maintained in both groups. Renal, intestinal, and splenic flows decreased and resistances increased in both groups by 15 min and returned to control levels by 3 h only in the LD0 trauma group. Total hepatic and hepatic portal flows decreased at 60 min and returned to control levels at 3 h after LD0 trauma, while there was significant depression in these parameters 3 h after LD50 trauma. Therefore, sublethal and severe trauma resulted in early redistribution of flow favoring the coronary, cerebral, and hepatic arterial beds. However, renal, intestinal, splenic, and portal flows remained depressed only in severely traumatized rats, suggesting that continued hypofusion is a factor in the multiple organ failure and death following severe traumatic injury

  20. Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia

    DEFF Research Database (Denmark)

    Hove, Jens D; Kofoed, Klaus F; Wu, Hsiao M

    2003-01-01

    The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia.......The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia....

  1. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography.

    LENUS (Irish Health Repository)

    Weisz, Dany E

    2012-01-01

    Non-invasive cardiac output monitoring is a potentially useful clinical tool in the neonatal setting. Our aim was to evaluate a new method of non-invasive continuous cardiac output (CO) measurement (NICOM™) based on the principle of bioreactance in neonates.

  2. Kredsløbsmonitorering med lithium dilution cardiac output-systemet

    DEFF Research Database (Denmark)

    Christiansen, Christian; Hostrup, Anette; Tønnesen, Else

    2008-01-01

    The lithium dilution cardiac output (LiDCO) system measures cardiac output beat-to-beat with high precision. The system is based on an arterial pulse power analysis which is calibrated every eight hours with a small non-pharmacological dose of lithium. The system is minimally invasive; it requires...

  3. [Measurement of cardiac output by thermodilution with a diode as a temperature sensor].

    Science.gov (United States)

    Díaz Fernández, A; Benítez, D; Sánchez Tello, G; Márquez, L A

    1979-01-01

    An area integrator for the thermodilution curve in cardiac output measurement is described. A new temperature sensor is used, a diode with some advantages over the thermistor normally used. The main advantages are: easy calibration and replacement, and broad range of linearity. The cardiac output values obtained in dog with the integrator follow a linear relationship with those of the flowmeter. In simultaneous measurements the correlation is R = 0.96. Using a diode as temperature sensor a modification of the Steward Hamilton equation (used for thermistor) is necessary. With this new equation a monogram is performed to calculate the cardiac output from the area given by the numerical integrator.

  4. Acupuncture therapy related cardiac injury.

    Science.gov (United States)

    Li, Xue-feng; Wang, Xian

    2013-12-01

    Cardiac injury is the most serious adverse event in acupuncture therapy. The causes include needling chest points near the heart, the cardiac enlargement and pericardial effusion that will enlarge the projected area on the body surface and make the proper depth of needling shorter, and the incorrect needling method of the points. Therefore, acupuncture practitioners must be familiar with the points of the heart projected area on the chest and the correct needling methods in order to reduce the risk of acupuncture therapy related cardiac injury.

  5. Left ventricular atrioventricular plane displacement is preserved with lifelong endurance training and is the main determinant of maximal cardiac output

    DEFF Research Database (Denmark)

    Steding-Ehrenborg, Katarina; Boushel, Robert C; Calbet, José A

    2015-01-01

    subjects (29 ± 4 years) underwent cardiac MR. All subjects underwent maximal exercise testing and for elderly subjects maximal cardiac output during cycling was determined using dye dilution technique. RESULTS: Longitudinal and radial contribution to stroke volume did not differ between groups......BACKGROUND: Age-related decline in cardiac function can be prevented or postponed by lifelong endurance training. However, effects of normal ageing as well as of lifelong endurance exercise on longitudinal and radial contribution to stroke volume are unknown. The aim of this study was to determine...... groups for RVAVPD (P = 0.2). LVAVPD was an independent predictor of maximal cardiac output (R(2 = ) 0.61, P groups. However, how longitudinal pumping...

  6. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Hansen, K L; Ostergaard, M

    2012-01-01

    BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring...

  7. Comparison of dye dilution method to radionuclide techniques for cardiac output determination in dogs

    International Nuclear Information System (INIS)

    Eng, S.S.; Robayo, J.R.; Porter, W.; Smith, R.E.

    1980-01-01

    A study was undertaken to identify the most accurate /sup 99m/Tc-labeled radiopharmaceutical and to determine the accuracy of a noninvasive radionuclide technique or cardiac output determinations. Phase I employed sodium pertechnetate, stannous pyrophosphate with sodium pertechnetate, /sup 99m/Tc red blood cells, and /sup 99m/Tc human serum albumin as radionuclide tracers. Cardiac output was determined by the dye dilution method and then by the invasive radionuclide technique. A pairied t test and regression analysis indicated that /sup 99m/Tc human serum albumin was the most accurate radiopharmaceutical for cardiac output determinations, and the results compared favorably to those obtained by the dye dilution method. In Phase II, /sup 99m/Tc human serum albumin was used as the radionuclide tracer for cardiac output determinations with the noninvasive technique. The results compared favorably to those obtained by the dye dilution method

  8. High-output cardiac failure secondary to multiple vascular malformations in the liver: case report

    International Nuclear Information System (INIS)

    Spaner, S.; Demeter, S.; Lien, D.; Shapiro, J.; McCarthy, M.; Raymond, G.

    2001-01-01

    High-output cardiac failure is associated with several systemic illnesses, including hyperthyroidism, thiamine deficiency, severe anemia, multiple myeloma, Paget's disease of bone and Osler-Weber-Rendu syndrome. We present an unusual case of a woman with high-output cardiac failure as a result of multiple arteriovenous fistulas in the liver, most likely representing an unusual variant of Osler-Weber-Rendu syndrome (i.e., no other telangiectasias or a family history of vascular malformations was demonstrated). (author)

  9. Determination of myocardial energetic output for cardiac rhythm pacing

    Czech Academy of Sciences Publication Activity Database

    Heřman, D.; Převorovská, Světlana; Maršík, František

    2007-01-01

    Roč. 7, č. 4 (2007), s. 156-161 ISSN 1567-8822 R&D Projects: GA ČR GA106/03/1073 Institutional research plan: CEZ:AV0Z20760514 Keywords : heart arrhythmia * cardiac pacing modes * numerical simulation Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  10. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  11. Serum cortisol concentration with exploratory cut-off values do not predict the effects of hydrocortisone administration in children with low cardiac output after cardiac surgery

    NARCIS (Netherlands)

    Verweij, E. J.; Hogenbirk, Karin; Roest, Arno A. W.; van Brempt, Ronald; Hazekamp, Mark G.; de Jonge, Evert

    2012-01-01

    Low cardiac output syndrome is common after paediatric cardiac surgery. Previous studies suggested that hydrocortisone administration may improve haemodynamic stability in case of resistant low cardiac output syndrome in critically ill children. This study was set up to test the hypothesis that the

  12. Transit time dispersion in pulmonary and systemic circulation: effects of cardiac output and solute diffusivity.

    Science.gov (United States)

    Weiss, Michael; Krejcie, Tom C; Avram, Michael J

    2006-08-01

    We present an in vivo method for analyzing the distribution kinetics of physiological markers into their respective distribution volumes utilizing information provided by the relative dispersion of transit times. Arterial concentration-time curves of markers of the vascular space [indocyanine green (ICG)], extracellular fluid (inulin), and total body water (antipyrine) measured in awake dogs under control conditions and during phenylephrine or isoproterenol infusion were analyzed by a recirculatory model to estimate the relative dispersions of transit times across the systemic and pulmonary circulation. The transit time dispersion in the systemic circulation was used to calculate the whole body distribution clearance, and an interpretation is given in terms of a lumped organ model of blood-tissue exchange. As predicted by theory, this relative dispersion increased linearly with cardiac output, with a slope that was inversely related to solute diffusivity. The relative dispersion of the flow-limited indicator antipyrine exceeded that of ICG (as a measure of intravascular mixing) only slightly and was consistent with a diffusional equilibration time in the extravascular space of approximately 10 min, except during phenylephrine infusion, which led to an anomalously high relative dispersion. A change in cardiac output did not alter the heterogeneity of capillary transit times of ICG. The results support the view that the relative dispersions of transit times in the systemic and pulmonary circulation estimated from solute disposition data in vivo are useful measures of whole body distribution kinetics of indicators and endogenous substances. This is the first model that explains the effect of flow and capillary permeability on whole body distribution of solutes without assuming well-mixed compartments.

  13. The decrease of cardiac chamber volumes and output during positive-pressure ventilation

    DEFF Research Database (Denmark)

    Kristensen, Kasper Kyhl; Ahtarovski, Kiril Aleksov; Iversen, Kasper

    2013-01-01

    the effect of PPV on the central circulation by studying cardiac chamber volumes with cardiac magnetic resonance imaging (CMR). We hypothesized that PPV lowers cardiac output (CO) mainly via the Frank-Starling relationship. In 18 healthy volunteers, cardiac chamber volumes and flow in aorta and the pulmonary...... artery were measured by CMR during PPV levels of 0, 10, and 20 cmH2O applied via a respirator and a face mask. All cardiac chamber volumes decreased in proportion to the level of PPV. Following 20-cmH2O PPV, the total diastolic and systolic cardiac volumes (±SE) decreased from 605 (±29) ml to 446 (±29......) ml (P volume decreased by 27 (±4) ml/beat; heart rate increased by 7 (±2) beats/min; and CO decreased by 1.0 (±0.4) l/min (P

  14. Cardiac Output and Performance during a Marathon Race in Middle-Aged Recreational Runners

    OpenAIRE

    Billat, Véronique L.; Petot, Hélène; Landrain, Morgan; Meilland, Renaud; Koralsztein, Jean Pierre; Mille-Hamard, Laurence

    2012-01-01

    Purpose. Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV) and cardiac output (CO) to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance) and/or CO, per meter (i.e., cardiac cost). Methods. We measured the SV, heart rate (HR), CO, and running speed of 14 recreational runners in an incremental, maxima...

  15. Phlebotomy eliminates the maximal cardiac output response to six weeks of exercise training

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian; Doucende, Gregory; Flück, Daniela

    2014-01-01

    With this study we tested the hypothesis that six weeks of endurance training increases maximal cardiac output (Qmax) relatively more by elevating blood volume (BV) than by inducing structural and functional changes within the heart. Nine healthy but untrained volunteers (VO2max 47 ± 5 ml.min(-1......).kg(-1)) underwent supervised training (60 min; 4 times weekly at 65% VO2max for six weeks) and Qmax was determined by inert gas re-breathing during cycle ergometer exercise before and after the training period. After the training period, blood volume (determined in duplicates by CO re......-breathing) was re-established to pre-training values by phlebotomy and Qmax was quantified again. Resting echography revealed no structural heart adaptations as a consequence of the training intervention. Following the training period, plasma volume (PV), red blood cell volume (RBCV) and BV increased (p...

  16. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Directory of Open Access Journals (Sweden)

    Amann Matthias

    2007-11-01

    Full Text Available Abstract Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC measurement by the pulmonary artery catheter (PAC. However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years, who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min. The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC and percentage changes in COAP (ΔCOAP for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p PAC and ΔCOAP was 0.46 (p Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03 failed to

  17. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Science.gov (United States)

    Prasser, Christopher; Bele, Sylvia; Keyl, Cornelius; Schweiger, Stefan; Trabold, Benedikt; Amann, Matthias; Welnhofer, Julia; Wiesenack, Christoph

    2007-01-01

    Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC) and percentage changes in COAP (ΔCOAP) for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p < 0.01), while the correlation coefficient between ΔCOPAC and ΔCOAP was 0.46 (p < 0.01). Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore

  18. Impedance cardiography: a comparison of cardiac output vs waveform analysis for assessing left ventricular systolic dysfunction.

    Science.gov (United States)

    DeMarzo, Arthur P; Kelly, Russell F; Calvin, James E

    2007-01-01

    Early detection of asymptomatic left ventricular systolic dysfunction (LVSD) is beneficial in managing heart failure. Recent studies have cast doubt on the usefulness of cardiac output as an indicator of LVSD. In impedance cardiography (ICG), the dZ/dt waveform has a systolic wave called the E wave. This study looked at measurements of the amplitude and area of the E wave compared with ICG-derived cardiac output, stroke volume, cardiac index, and stroke index as methods of assessing LVSD. ICG data were obtained from patients (n=26) admitted to a coronary care unit. Clinical LVSD severity was stratified into 4 groups (none, mild, moderate, and severe) based on echocardiography data and standard clinical assessment by a cardiologist blinded to ICG data. Statistical analysis showed that the E wave amplitude and area were better indicators of the level of LVSD than cardiac output, stroke volume, cardiac index, or stroke index. ICG waveform analysis has potential as a simple point-of-care test for detecting LVSD in asymptomatic patients at high risk for developing heart failure and for monitoring LVSD in patients being treated for heart failure.

  19. Clinical Validation of Non-Invasive Cardiac Output Monitoring in Healthy Pregnant Women.

    Science.gov (United States)

    McLaughlin, Kelsey; Wright, Stephen P; Kingdom, John C P; Parker, John D

    2017-11-01

    Non-invasive hemodynamic monitoring has the potential to be a valuable clinical tool for the screening and management of hypertensive disorders of pregnancy. The objective of this study was to validate the clinical utility of the non-invasive cardiac output monitoring (NICOM) system in pregnant women. Twenty healthy pregnant women with a singleton pregnancy at 22 to 26 weeks' gestation were enrolled in this study. Measures of heart rate, stroke volume, and cardiac output were obtained through NICOM and compared with Doppler echocardiography. NICOM significantly overestimated measures of both stroke volume and cardiac output compared with Doppler echocardiography (95 ± 4 vs. 73 ± 4 mL, P gold standard for the measurement of cardiac output in the setting of pregnancy. However, once normal values have been established, NICOM has the potential to be a useful clinical tool for monitoring maternal hemodynamics in pregnant women. Further investigation regarding the validity of NICOM is required in larger populations of healthy and hypertensive pregnant women to determine whether this device is appropriate for maternal hemodynamic assessment during pregnancy. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  20. Rowing increases stroke volume and cardiac output to a greater extent than cycling

    Czech Academy of Sciences Publication Activity Database

    Horn, P.; Ošťádal, P.; Ošťádal, Bohuslav

    2015-01-01

    Roč. 64, č. 2 (2015), s. 203-207 ISSN 0862-8408 Institutional support: RVO:67985823 Keywords : cardiac output * cycling * heart rate * stroke volume Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.643, year: 2015

  1. Relationship between stroke volume, cardiac output and filling of the heart during tilt

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, M.; Sorensen, H.; Dalsgaard, M.

    2009-01-01

    . With the supine resting position as a reference, we assessed stroke volume (SV), cardiac output (CO) and filling of the heart during graded tilt to evaluate whether SV and CO are maintained during an assumed maximal physiological filling of the heart elicited by 90 degrees HDT in healthy resting humans. METHODS...

  2. Middle cerebral artery blood velocity depends on cardiac output during exercise with a large muscle mass

    NARCIS (Netherlands)

    Ide, K.; Pott, F.; van Lieshout, J. J.; Secher, N. H.

    1998-01-01

    We tested the hypothesis that pharmacological reduction of the increase in cardiac output during dynamic exercise with a large muscle mass would influence the cerebral blood velocity/perfusion. We studied the relationship between changes in cerebral blood velocity (transcranial Doppler), rectus

  3. Changes in cardiac output and incidence of volume overload in cirrhotics receiving 20% albumin infusion.

    Science.gov (United States)

    Shasthry, Saggere M; Kumar, Manoj; Khumuckham, Jelen S; Sarin, Shiv Kumar

    2017-08-01

    Patients with cirrhosis are prone to develop volume over load, have increased capillary permeability and latent or overt cardiomyopathy. Whether albumin infusion causes volume overload in cirrhotics has not been adequately studied. Ninety nine consecutive cirrhotic patients receiving 1gm per kg albumin infusion were evaluated for development of volume overload. Clinical, echocardiographic and haemodynamic changes were closely monitored during and after albumin infusion. Thirty (30.30%) patients developed volume overload. Patients with higher BMI (P=.003), lower CTP (P=.01) and MELD (P=.034) were more often associated with the development of volume overload. Though baseline diastolic dysfunction was present in 82.8% of the patients, it did not influence the development of volume overload or changes in the cardiac output. The cardiac output increased significantly after albumin infusion (4.9±1.554 L/min to 5.86±1.85 L/min, Palbumin infusion develop volume overload, specially, those with higher BMI and lower severity of liver disease. Cardiac output increases after albumin infusion, and, baseline diastolic dysfunction has little effect on the development of volume overload or changes in cardiac output. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Non-invasive measurements of cardiac output in atrial fibrillation: Inert gas rebreathing and impedance cardiography

    DEFF Research Database (Denmark)

    Osbak, Philip S; Henriksen, Jens Henrik Sahl; Kofoed, Klaus F

    2011-01-01

    Abstract Background. Atrial fibrillation (AF) is associated with significant morbidity and mortality. To test the effect of interventions, knowledge of cardiac output (CO) is important. However, the irregular heart rate might cause some methods for determination of CO to have inherent weaknesses....

  5. Effect of Hemorrhage on Cardiac Output, PVP, Alodosterone and Diuresis during Immersion in Men

    Science.gov (United States)

    Simanonok, K.; Greenleaf, John E.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1990-01-01

    The purpose of this study was to test the hypothesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q (sup dot) sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses.

  6. A-V Delay Versus Cardiac Output Measured with Thorax Bioimpedance Monitor

    Czech Academy of Sciences Publication Activity Database

    Vondra, Vlastimil; Halámek, Josef; Viščor, Ivo; Jurák, Pavel; Novák, M.; Lipoldová, J.

    2008-01-01

    Roč. 6, č. 1 (2008), s. 73 ISSN 1556-7451. [World Congress on Heart Disease /14./. 26.07.2008-29.07.2008, Toronto] Institutional research plan: CEZ:AV0Z20650511 Keywords : atrio-ventricular delay * resynchronization therapy * impedance cardiography * cardiac output Subject RIV: FA - Cardiovascular Disease s incl. Cardiotharic Surgery

  7. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  8. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    International Nuclear Information System (INIS)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L; De Boode, W P; Huisman, H J; Kapusta, L

    2009-01-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  9. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  10. Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph

    International Nuclear Information System (INIS)

    Inan, O T; Etemadi, M; Giovangrandi, L; Kovacs, G T A; Paloma, A

    2009-01-01

    Cardiac ejection of blood into the aorta generates a reaction force on the body that can be measured externally via the ballistocardiogram (BCG). In this study, a commercial bathroom scale was modified to measure the BCGs of nine healthy subjects recovering from treadmill exercise. During the recovery, Doppler echocardiogram signals were obtained simultaneously from the left ventricular outflow tract of the heart. The percentage changes in root-mean-square (RMS) power of the BCG were strongly correlated with the percentage changes in cardiac output measured by Doppler echocardiography (R 2 = 0.85, n = 275 data points). The correlation coefficients for individually analyzed data ranged from 0.79 to 0.96. Using Bland–Altman methods for assessing agreement, the mean bias was found to be −0.5% (±24%) in estimating the percentage changes in cardiac output. In contrast to other non-invasive methods for trending cardiac output, the unobtrusive procedure presented here uses inexpensive equipment and could be performed without the aid of a medical professional

  11. Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph.

    Science.gov (United States)

    Inan, O T; Etemadi, M; Paloma, A; Giovangrandi, L; Kovacs, G T A

    2009-03-01

    Cardiac ejection of blood into the aorta generates a reaction force on the body that can be measured externally via the ballistocardiogram (BCG). In this study, a commercial bathroom scale was modified to measure the BCGs of nine healthy subjects recovering from treadmill exercise. During the recovery, Doppler echocardiogram signals were obtained simultaneously from the left ventricular outflow tract of the heart. The percentage changes in root-mean-square (RMS) power of the BCG were strongly correlated with the percentage changes in cardiac output measured by Doppler echocardiography (R(2) = 0.85, n = 275 data points). The correlation coefficients for individually analyzed data ranged from 0.79 to 0.96. Using Bland-Altman methods for assessing agreement, the mean bias was found to be -0.5% (+/-24%) in estimating the percentage changes in cardiac output. In contrast to other non-invasive methods for trending cardiac output, the unobtrusive procedure presented here uses inexpensive equipment and could be performed without the aid of a medical professional.

  12. Is pulmonary gas exchange during exercise in hypoxia impaired with the increase of cardiac output?

    DEFF Research Database (Denmark)

    Calbet, J.A.; Robach, P.; Lundby, C.

    2008-01-01

    During exercise in humans, the alveolar-arterial O(2) tension difference ((A-a)DO(2)) increases with exercise intensity and is an important factor determining the absolute level of oxygen binding to hemoglobin and therefore the level of systemic oxygen transport. During exercise in hypoxia, the (A......-a)DO(2) is accentuated. Using the multiple inert gas elimination technique it has been shown that during exercise in acute hypoxia the contribution of ventilation-perfusion inequality to (A-a)DO(2) is rather small and in the absence of pulmonary edema intrapulmonary shunts can be ruled out. This implies...... that the main mechanism limiting pulmonary gas exchange is diffusion limitation. It is presumed that an elevation of cardiac output during exercise in acute hypoxia should increase the (A-a)DO(2). However, no studies have examined how variations in cardiac output independently affect pulmonary diffusion...

  13. Cardiac output and performance during a marathon race in middle-aged recreational runners.

    Science.gov (United States)

    Billat, Véronique L; Petot, Hélène; Landrain, Morgan; Meilland, Renaud; Koralsztein, Jean Pierre; Mille-Hamard, Laurence

    2012-01-01

    Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV) and cardiac output (CO) to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance) and/or CO, per meter (i.e., cardiac cost). We measured the SV, heart rate (HR), CO, and running speed of 14 recreational runners in an incremental, maximal laboratory test and then during a real marathon race (mean performance: 3 hr 30 min ± 45 min). Our data revealed that HR, SV and CO were all in a high but submaximal steady state during the marathon (87.0 ± 1.6%, 77.2 ± 2.6%, and 68.7 ± 2.8% of maximal values, respectively). Marathon performance was inversely correlated with an upward drift in the CO/speed ratio (mL of CO × m(-1)) (r = -0.65, P marathon performance is inversely correlated with cardiac cost and positively correlated with cardiac endurance. The CO response could be a benchmark for race performance in recreational marathon runners.

  14. Low cardiac output predicts development of hepatorenal syndrome and survival in patients with cirrhosis and ascites

    DEFF Research Database (Denmark)

    Krag, A; Bendtsen, F; Møller, S

    2010-01-01

    (130 (SD 46) vs 78 (SD 29) mumol/l, psyndrome type 1 within 3 months was higher in the group with low CI than in the high CI group (43% vs 5%, p = 0.04). Patients with the lowest CI (N = 8) had significantly poorer survival at 3, 9, and 12 months......OBJECTIVES: Recent studies suggest that cardiac dysfunction precedes development of the hepatorenal syndrome. In this follow-up study, we aimed to investigate the relation between cardiac and renal function in patients with cirrhosis and ascites and the impact of cardiac systolic function...

  15. Mathematical basis for the measurement of absolute and fractional cardiac output with diffusible tracers by compartmental analysis methods

    International Nuclear Information System (INIS)

    Charkes, N.D.

    1984-01-01

    Using compartmental analysis methods, a mathematical basis is given for the measurement of absolute and fractional cardiac output with diffusible tracers. Cardiac output is shown to be the product of the blood volume and the sum of the rate constants of tracer egress from blood, modified by a factor reflecting transcapillary diffusibility, the transfer fraction. The return of tracer to the blood and distant (intracellular) events are shown to play no role in the solution. Fractional cardiac output is the ratio of the rate constant of tracer egress from blood to an organ, divided by the sum of the egress constants from blood. Predominantly extracellular ions such as sodium or bromide are best suited for this technique, although theoretically any diffusible tracer whose compartmental model can be solved may be used. It is shown that fractional cardiac output is independent of the transfer fraction, and therefore can be measured accurately by tracers which are not freely diffusible

  16. Chronic resuscitation after trauma-hemorrhage and acute fluid replacement improves hepatocellular function and cardiac output.

    Science.gov (United States)

    Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H

    1998-01-01

    To determine whether prolonged (chronic) resuscitation has any beneficial effects on cardiac output and hepatocellular function after trauma-hemorrhage and acute fluid replacement. Acute fluid resuscitation after trauma-hemorrhage restores but does not maintain the depressed hepatocellular function and cardiac output. Male Sprague-Dawley rats underwent a 5-cm laparotomy (i.e., trauma was induced) and were bled to and maintained at a mean arterial pressure of 40 mmHg until 40% of maximal bleed-out volume was returned in the form of Ringer's lactate (RL). The animals were acutely resuscitated with RL using 4 times the volume of maximum bleed-out over 60 minutes, followed by chronic resuscitation of 0, 5, or 10 mL/kg/hr RL for 20 hours. Hepatocellular function was determined by an in vivo indocyanine green clearance technique. Hepatic microvascular blood flow was assessed by laser Doppler flowmetry. Plasma levels of interleukin-6 (IL-6) were determined by bioassay. Chronic resuscitation with 5 mL/kg/hr RL, but not with 0 or 10 mL/kg/hr RL, restored cardiac output, hepatocellular function, and hepatic microvascular blood flow at 20 hours after hemorrhage. The regimen above also reduced plasma IL-6 levels. Because chronic resuscitation with 5 mL/kg/hr RL after trauma-hemorrhage and acute fluid replacement restored hepatocellular function and hepatic microvascular blood flow and decreased plasma levels of IL-6, we propose that chronic fluid resuscitation in addition to acute fluid replacement should be routinely used in experimental studies of trauma-hemorrhage.

  17. Hereditary Hemorrhagic Telangiectasia Presenting as High Output Cardiac Failure during Pregnancy

    Directory of Open Access Journals (Sweden)

    Tareq Goussous

    2009-01-01

    Full Text Available High-output cardiac failure secondary to hepatic involvement is a rare complication of hereditary hemorrhagic telangiectasia (HHT. Here we report a 43-year-old woman who presented at 29 weeks gestation of her second pregnancy with complications of right-sided heart failure and preterm labor. After delivery via cesarean section, the patient was found to have intrahepatic arteriovenous malformations through non-invasive imaging. Subsequently, a family history of vascular malformations and epistaxis was elucidated and a diagnosis of HHT was made. This case is presented, along with a review of the literature and discussion of hepatic involvement in HHT with particular focus on the pregnant patient.

  18. Effects of levosimendan for low cardiac output syndrome in critically ill patients

    DEFF Research Database (Denmark)

    Koster, Geert; Wetterslev, Jørn; Gluud, Christian

    2015-01-01

    PURPOSE: To assess the benefits and harms of levosimendan for low cardiac output syndrome in critically ill patients. METHODS: We conducted a systematic review with meta-analyses and trial sequential analyses (TSA) of randomised clinical trials comparing levosimendan with any type of control. Two...... in the systematic review and 49 trials (6,688 patients) in the meta-analysis. One trial had low risk of bias and nine trials (2,490 patients) were considered lower risk of bias. Trials compared levosimendan with placebo, control interventions, and other inotropes. Pooling all trials including heterogenous...

  19. Pulmonary Artery Catheter (PAC Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM: An Ovine Cardiac Output Validation

    Directory of Open Access Journals (Sweden)

    Robert A. Phillips

    2012-01-01

    Full Text Available Background. The pulmonary artery catheter (PAC is an accepted clinical method of measuring cardiac output (CO despite no prior validation. The ultrasonic cardiac output monitor (USCOM is a noninvasive alternative to PAC using Doppler ultrasound (CW. We compared PAC and USCOM CO measurements against a gold standard, the aortic flow probe (FP, in sheep at varying outputs. Methods. Ten conscious sheep, with implanted FPs, had measurements of CO by FP, USCOM, and PAC, at rest and during intervention with inotropes and vasopressors. Results. CO measurements by FP, PAC, and USCOM were 4.0±1.2 L/min, 4.8±1.5 L/min, and 4.0±1.4 L/min, respectively, (=280, range 1.9 L/min to 11.7 L/min. Percentage bias and precision between FP and PAC, and FP and USCOM was −17 and 47%, and 1 and 36%, respectively. PAC under-measured Dobutamine-induced CO changes by 20% (relative 66% compared with FP, while USCOM measures varied from FP by 3% (relative 10%. PAC reliably detected −30% but not +40% CO changes, as measured by receiver operating characteristic area under the curve (AUC, while USCOM reliably detected ±5% changes in CO (AUC>0.70. Conclusions. PAC demonstrated poor accuracy and sensitivity as a measure of CO. USCOM provided equivalent measurements to FP across a sixfold range of outputs, reliably detecting ±5% changes.

  20. Factors related to innovative output in the Dutch agrifood industry

    NARCIS (Netherlands)

    Batterink, M.H.; Wubben, E.F.M.; Omta, S.W.F.

    2006-01-01

    The present study assessed the factors related to innovative output in the Dutch agrifood industry, a scale-intensive, supplierdominated industry. We concentrated on explanatory variables related to cooperation, information sources, innovation objectives, obstacles to innovation, and innovation

  1. Cardiac Output and Performance during a Marathon Race in Middle-Aged Recreational Runners

    Directory of Open Access Journals (Sweden)

    Véronique L. Billat

    2012-01-01

    Full Text Available Purpose. Despite the increasing popularity of marathon running, there are no data on the responses of stroke volume (SV and cardiac output (CO to exercise in this context. We sought to establish whether marathon performance is associated with the ability to sustain high fractional use of maximal SV and CO (i.e, cardiac endurance and/or CO, per meter (i.e., cardiac cost. Methods. We measured the SV, heart rate (HR, CO, and running speed of 14 recreational runners in an incremental, maximal laboratory test and then during a real marathon race (mean performance: 3 hr 30 min ± 45 min. Results. Our data revealed that HR, SV and CO were all in a high but submaximal steady state during the marathon (87.0 ± 1.6%, 77.2 ± 2.6%, and 68.7 ± 2.8% of maximal values, respectively. Marathon performance was inversely correlated with an upward drift in the CO/speed ratio (mL of CO×m−1 (r=−0.65, P<0.01 and positively correlated with the runner’s ability to complete the race at a high percentage of the speed at maximal SV (r=0.83, P<0.0002. Conclusion. Our results showed that marathon performance is inversely correlated with cardiac cost and positively correlated with cardiac endurance. The CO response could be a benchmark for race performance in recreational marathon runners.

  2. Predictors of Post Pericardiotomy Low Cardiac Output Syndrome in Patients With Pericardial Effusion

    Directory of Open Access Journals (Sweden)

    Sabzi Feridoun

    2015-03-01

    Full Text Available Introduction: Pathological involvement of pericardium by any disease that resulting in effusion may require decompression and pericardiectomy. The current article describes rare patients with effusion who after pericadiectomy and transient hemodynamic improvement rapidly developed progressive heart failure and subsequent multi organ failure.Methods: During periods of five years, 423 patients in our hospital underwent pericardiotomy for decompression of effusion. The clinical characteristics of those patient with postoperative low cardiac output (B group (14 cases recorded and compared with other patients without this postoperative complication (A group by test and X2. Significant variables in invariables (P≤0.1 entered in logistic regression analysis and odd ratio of these significant variables obtained. Results: Idiopathic pericardial effusion, malignancy, renal failure, connective tissue disease, viral pericarditis was found in 125 patients (27%, 105 patients (25.4%, 65 patients (15.6%, 50 (17.1% and 10 (2.4% of patients subsequently. The factors that predict post-operative death in logistic regression analysis were malignancy, radiotherapy, constrictive pericarditis inotropic drug using IABP using, pre-operative EF and pericardial calcification.Conclusion: Certain preoperative variables such as malignancy, radiotherapy, low EF, calcified pericardium and connective tissue disease are associated with POLCOS and post-operative risk of death. This paradoxical response to pericardial decompression may be more frequent than currently appreciated. Its cause may relate to the sudden removal of the chronic external ventricular support from the effusion or thicken pericardium resulting in ventricular dilatation and failure or intra operative myocardial injury due to pericardiectomy of calcified pericardium, radiation and cardiomyopathy.

  3. The Unpredictable Effect of Changing Cardiac Output on Hypoxemia after Acute Pulmonary Thromboembolism

    Directory of Open Access Journals (Sweden)

    John Y. C. Tsang

    2008-01-01

    Full Text Available Previous studies reported that the degree of hypoxemia following acute pulmonary thromboembolism (APTE was highly variable and that its mechanism was mainly due to the creation of many high and low ventilation/perfusion (V/Q units, as a result of the heterogeneous regional blood flow (Q caused by embolic obstruction. We studied the effect of changing cardiac output (Q t on gas exchange after APTE in 5 embolized piglets (23 ± 3 Kg, using Dobutamine intermittently at approximately 20 μg/kg/min for 120 minutes. The distribution of ventilation (V and perfusion (Q at various times was mapped using fluorescent microspheres in 941 ± 60 lung regions. After APTE, increase in Q t by Dobutamine improved venous oxygen tension (PvO 2 but arterial PaO 2 did not change consistently. On the other hand, cluster analysis showed that the V/Q ratio of most lung regions was lowered due to increases in Q at the same time. We concluded that the effect of changing cardiac output on gas exchange following APTE was affected by the simultaneous and varying balance between the changing V/Q mismatch and the concomitantly changing PvO 2 , which might explain the unpredictability of PaO 2 in the clinical setting.

  4. Reference values for total blood volume and cardiac output in humans

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  5. Immediate changes in estimated cardiac output and vascular resistance after 60Co exposure in monkeys: implication for performance decrement

    International Nuclear Information System (INIS)

    Bruner, A.

    1977-01-01

    Aortic blood flow velocity, blood pressure, and heart rate were recorded in 12 unanesthetized, nonperforming monkeys during exposure to 1000 rad 60 Co at 129--164 rad/min. The first postradiation changes were seen within 3--4 min of the exposure's start and included tachycardia, a transient hypotension secondary to a loss in peripheral resistance, and a brief increase followed by a decrease to subnormal levels in cardiac output. The lowest cardiac output occurred between 10 and 20 min postexposure while blood pressure and peripheral resistance were recovering. It was proposed that the concurrent combination of low cardiac output, low blood pressure, and supranormal peripheral resistance might sufficiently attenuate cerebral perfusion temporarily to account for the transient behavioral decrements often seen during this time. Histamine release was postulated as responsible for this vascular shock syndrome

  6. Non-invasive measurement of cardiac output during anaesthesia. An evaluation of the soluble gas uptake method

    Energy Technology Data Exchange (ETDEWEB)

    Heneghan, C.P.; Branthwaite, M.A.

    1981-04-01

    A technique for measuring cardiac output which depends on the uptake of an inert soluble gas from the lungs has been evaluated during anesthesia. A respiratory mass spectrometer has been used to follow the concentrations of argon and freon-22 during passive rebreathing in anaesthetized patients before cardiopulmonary bypass. Values for cardiac output obtained with this technique are reproducible, but lower than those recorded using the direct Fick technique before and after the rebreathing manoeuvre. A reduction in cardiac output caused by vigorous rebreathing is the most likely explanation for the discrepancy and, although serial measurements of oxygen consumption may permit application of a correction factor, a method of measurement which causes significant haemodynamic disturbance cannot be recommended for widespread use.

  7. Nasal continuous positive airway pressure (n-CPAP) does not change cardiac output in preterm infants.

    Science.gov (United States)

    Moritz, Barbara; Fritz, Michael; Mann, Christian; Simma, Burkhard

    2008-02-01

    Our objective was to study how invasive mechanical ventilation impairs cardiac output (CO) in children and adults. Although the application of continuous positive airway pressure (CPAP) is widely practiced in neonatal intensive care, its hemodynamic consequences have not yet been investigated. A prospective study to assess the hemodynamic effects was conducted in 21 preterm infants CPAP (n-CPAP). Gestational age was 28.0 +/- 1.9 weeks (mean +/- standard deviation); birthweight, 1000 +/- 238 g; age at study entry, 200 +/- 155 hours; total maintenance fluid, 154 +/- 42 mL/kg/day; and n-CPAP level, 4.4 +/- 0.9 cm H(2)O. None of the infants received inotropic support, and n-CPAP did not cause any significant difference in the parameters measured: stroke volume, 3.1 +/- 1.0 mL (with n-CPAP) versus 3.1 +/- 1.0 mL (without n-CPAP); cardiac output, 487 +/- 156 mL/minute versus 500 +/- 176 mL/minute; left ventricular diastolic diameter, 1.22 +/- 0.15 cm versus 1.24 +/- 0.14 cm; fractional shortening, 0.30 +/- 0.05% versus 0.29 +/- 0.04%; and aortic velocity-time integral, 8.64 +/- 1.80 cm versus 8.70 +/- 1.65 cm. The n-CPAP level did not influence CO; n-CPAP (up to 7 cm H (2)O) has no echocardiographically detectable hemodynamic effect in preterm infants. Our data imply there is no need to withhold n-CPAP support to prevent circulatory compromise in these infants.

  8. Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure.

    Science.gov (United States)

    Roth, Sebastian; Fox, Henrik; Fuchs, Uwe; Schulz, Uwe; Costard-Jäckle, Angelika; Gummert, Jan F; Horstkotte, Dieter; Oldenburg, Olaf; Bitter, Thomas

    2018-05-01

    Determination of cardiac output (CO) is essential in diagnosis and management of heart failure (HF). The gold standard to obtain CO is invasive assessment via thermodilution (TD). Noninvasive pulse contour analysis (NPCA) is supposed as a new method of CO determination. However, a validation of this method in HF is pending and performed in the present study. Patients with chronic-stable HF and reduced left ventricular ejection fraction (LVEF ≤ 45%; HF-REF) underwent right heart catheterization including TD. NPCA using the CNAP Monitor (V5.2.14, CNSystems Medizintechnik AG) was performed simultaneously. Three standardized TD measurements were compared with simultaneous auto-calibrated NPCA CO measurements. In total, 84 consecutive HF-REF patients were enrolled prospectively in this study. In 4 patients (5%), TD was not successful and for 22 patients (26%, 18 with left ventricular assist device), no NPCA signal could be obtained. For the remaining 58 patients, Bland-Altman analysis revealed a mean bias of + 1.92 L/min (limits of agreement ± 2.28 L/min, percentage error 47.4%) for CO. With decreasing cardiac index, as determined by the gold standard of TD, there was an increasing gap between CO values obtained by TD and NPCA (r = - 0.75, p TD-CI classified 52 (90%) patients to have a reduced CI (REF patients, auto-calibrated NPCA systematically overestimates CO with decrease in cardiac function. Therefore, to date, NPCA cannot be recommended in this cohort.

  9. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution

    Directory of Open Access Journals (Sweden)

    Ole Broch

    2016-01-01

    Full Text Available Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO. The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB. Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A passive leg raising maneuver was also performed. Measurements included CO obtained by transpulmonary thermodilution (COTPTD and by nine pulse contour algorithms (COX1–9. Calibration of pulse contour algorithms was performed by esophageal Doppler ultrasound after induction of anesthesia and 15 min after CPB. Correlations, Bland-Altman analysis, four-quadrant, and polar analysis were also calculated. Results. There was only a poor correlation between COTPTD and COX1–9 during passive leg raising and in the period before and after CPB. Percentage error exceeded the required 30% limit. Four-quadrant and polar analysis revealed poor trending ability for most algorithms before and after CPB. The Liljestrand-Zander algorithm revealed the best reliability. Conclusions. Estimation of CO by nine different pulse contour algorithms revealed poor accuracy compared with transpulmonary thermodilution. Furthermore, the less-invasive algorithms showed an insufficient capability for trending hemodynamic changes before and after CPB. The Liljestrand-Zander algorithm demonstrated the highest reliability. This trial is registered with NCT02438228 (ClinicalTrials.gov.

  10. Depressed left and right ventricular cardiac output in fetuses of diabetic mothers

    Directory of Open Access Journals (Sweden)

    Jennifer Winter MD

    2018-01-01

    Full Text Available Introduction: We compared right and left ventricular cardiac output (RVCO and LVCO in fetuses of diabetic mothers (FDM with a large normal cohort. Methods: We prospectively enrolled 264 normal fetuses and 30 FDM. Fetal CO parameters such as semilunar valve velocity time integrals (AVVTI, PVVTI, ventricular outflow diameters (LVOTD, RVOTD and stroke volumes (AVSV, PVSV were measured, and LVCO and RVCO were calculated. These were normalized using non-linear regression to estimated fetal weight (EFW to provide means and standard deviations. Among FDMs, mean Z scores and 95% confidence limits (CL were calculated and compared to zero. Results: LVCO, RVCO and parameters they were calculated from, increased predictably and non-linearly with increasing EFW. In FDM, LVCO was depressed (mean Z −1.679, 95% CL −2.404, −0.955, P < 0.001, and AVVTI, LVOTD and AVSV were significantly lower than normal. Similarly, RVCO (mean Z = −1.119, CL −1.839, −0.400, P = 0.003, RVOTD (mean −2.085, CL −3.077, −1.093, P < 0.001 and PVSV (mean −1.184, CL −1.921, −0.446, P = 0.003 were lower than normal, however, PVVTI was not different (mean Z 0.078, CL −0.552, +0.707, P = 0.803. Conclusion: Normal biventricular stroke volumes and outputs follow a non-linear regression with EFW. FDM have significantly lower right and left heart stroke volumes and outputs for weight than do normal fetuses.

  11. Influence of heart motion on cardiac output estimation by means of electrical impedance tomography: a case study

    International Nuclear Information System (INIS)

    Proença, Martin; Braun, Fabian; Rapin, Michael; Solà, Josep; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Bohm, Stephan H; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets. (paper)

  12. Pulmonary diffusing capacity, capillary blood volume, and cardiac output during sustained microgravity

    Science.gov (United States)

    Prisk, G. K.; Guy, Harold J. B.; Elliott, Ann R.; Deutschman, Robert A., III; West, John B.

    1993-01-01

    We measured pulmonary diffusing capacity (DL), diffusing capacity per unit lung volume, pulmonary capillary blood volume (Vc), membrane diffusing capacity (Dm), pulmonary capillary blood flow or cardiac output (Qc), and cardiac stroke volume (SV) in four subjects exposed to nine days of microgravity. DL in microgravity was elevated compared with preflight standing values and was higher than preflight supine because of the elevation of both Vc and Dm. The elevation in Vc was comparable to that measured supine in 1 G, but the increase in Dm was in sharp contrast to the supine value. We postulate that, in 0 G, pulmonary capillary blood is evenly distributed throughout the lung, providing for uniform capillary filling, leading to an increase in the surface area available for diffusion. By contrast, in the supine 1-G state, the capillaries are less evenly filled, and although a similar increase in blood volume is observed, the corresponding increase in surface area does not occur. DL and its subdivisions showed no adaptive changes from the first measurement 24 h after the start of 0 G to eight days later. Similarly, there were no trends in the postflight data, suggesting that the principal mechanism of these changes was gravitational. The increase in Dm suggests that subclinical pulmonary edema did not result from exposure to 0 G. Qc was modestly increased inflight and decreased postflight compared with preflight standing. Compared with preflight standing, SV was increased 46 percent inflight and decreased 14 percent in the 1st week postflight. There were temporal changes in Qc and SV during 0 G, with the highest values recorded at the first measurement, 24 h into the flight. The lowest values of Qc and SV occurred on the day of return.

  13. Pilot Study: Estimation of Stroke Volume and Cardiac Output from Pulse Wave Velocity.

    Directory of Open Access Journals (Sweden)

    Yurie Obata

    Full Text Available Transesophageal echocardiography (TEE is increasingly replacing thermodilution pulmonary artery catheters to assess hemodynamics in patients at high risk for cardiovascular morbidity. However, one of the drawbacks of TEE compared to pulmonary artery catheters is the inability to measure real time stroke volume (SV and cardiac output (CO continuously. The aim of the present proof of concept study was to validate a novel method of SV estimation, based on pulse wave velocity (PWV in patients undergoing cardiac surgery.This is a retrospective observational study. We measured pulse transit time by superimposing the radial arterial waveform onto the continuous wave Doppler waveform of the left ventricular outflow tract, and calculated SV (SVPWV using the transformed Bramwell-Hill equation. The SV measured by TEE (SVTEE was used as a reference.A total of 190 paired SV were measured from 28 patients. A strong correlation was observed between SVPWV and SVTEE with the coefficient of determination (R2 of 0.71. A mean difference between the two (bias was 3.70 ml with the limits of agreement ranging from -20.33 to 27.73 ml and a percentage error of 27.4% based on a Bland-Altman analysis. The concordance rate of two methods was 85.0% based on a four-quadrant plot. The angular concordance rate was 85.9% with radial limits of agreement (the radial sector that contained 95% of the data points of ± 41.5 degrees based on a polar plot.PWV based SV estimation yields reasonable agreement with SV measured by TEE. Further studies are required to assess its utility in different clinical situations.

  14. Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive).

    Science.gov (United States)

    Lakhal, Karim; Ehrmann, Stephan; Perrotin, Dominique; Wolff, Michel; Boulain, Thierry

    2013-11-01

    To assess whether invasive and non-invasive blood pressure (BP) monitoring allows the identification of patients who have responded to a fluid challenge, i.e., who have increased their cardiac output (CO). Patients with signs of circulatory failure were prospectively included. Before and after a fluid challenge, CO and the mean of four intra-arterial and oscillometric brachial cuff BP measurements were collected. Fluid responsiveness was defined by an increase in CO ≥10 or ≥15% in case of regular rhythm or arrhythmia, respectively. In 130 patients, the correlation between a fluid-induced increase in pulse pressure (Δ500mlPP) and fluid-induced increase in CO was weak and was similar for invasive and non-invasive measurements of BP: r² = 0.31 and r² = 0.29, respectively (both p area under the receiver-operating curve (AUC) of 0.82 (0.74-0.88), similar (p = 0.80) to that of non-invasive Δ500mlPP [AUC of 0.81 (0.73-0.87)]. Outside large gray zones of inconclusive values (5-23% for invasive Δ500mlPP and 4-35% for non-invasive Δ500mlPP, involving 35 and 48% of patients, respectively), the detection of responsiveness or unresponsiveness to fluid was reliable. Cardiac arrhythmia did not impair the performance of invasive or non-invasive Δ500mlPP. Other BP-derived indices did not outperform Δ500mlPP. As evidenced by large gray zones, BP-derived indices poorly reflected fluid responsiveness. However, in our deeply sedated population, a high increase in invasive pulse pressure (>23%) or even in non-invasive pulse pressure (>35%) reliably detected a response to fluid. In the absence of a marked increase in pulse pressure (<4-5%), a response to fluid was unlikely.

  15. Management of perioperative low cardiac output state without extracorporeal life support: What is feasible?

    International Nuclear Information System (INIS)

    Kumar, Girish; Iyer, Parvathi U

    2010-01-01

    A transient and reversible reduction in cardiac output–low cardiac output state (LCOS) often occurs following surgery for congenital heart disease. Inappropriately managed LCOS is a risk factor for increased morbidity and death. LCOS may occasionally be progressive and refractory needing a period of “myocardial rest” with extracorporeal life support (ECLS). ECLS is currently considered a routine tool available for rapid deployment in most industrialized countries. Accumulated experience and refinements in technology have led to improving survivals – discharge survivals of 35%–50%, with almost 100% survival in select groups on elective left ventricular assist device. Thus, there is an increasing trend to initiate ECLS “early or electively in the operating room” in high-risk patients. India has a huge potential need for ECLS given the large number of infants presenting late with preexisting ventricular dysfunction or in circulatory collapse. ECLS is an expensive and resource consuming treatment modality and is not a viable therapeutic option in our country. The purpose of this paper is to reiterate an anticipatory, proactive approach to LCOS: (1) methods for early detection of evolving LCOS and (2) timely initiation of individualized therapy. This paper also explores what is feasible with the refinement of “simple, conventional, inexpensive strategies” for the management of LCOS. Therapy for LCOS should be multimodal based on the type of circulation and physiology. Our approach to LCOS includes: (1) intraoperative strategies, (2) aggressive afterload reduction, (3) lusitropy, (4) exclusion of structural defects, (5) harnessing cardiopulmonary interactions, and (6) addressing metabolic and endocrine abnormalities. We have achieved a discharge survival rate of greater than 97% with these simple methods

  16. Evaluation of concordance among three cardiac output measurement techniques in adult patients during cardiovascular surgery postoperative care.

    Science.gov (United States)

    Muñoz, L; Velandia, A; Reyes, L E; Arevalo-Rodríguez, I; Mejía, C; Asprilla, D; Uribe, D V; Arevalo, J J

    2017-12-01

    The standard method for cardiac output measuring is thermodilution although it is an invasive technique. Transesophageal Echocardiography (TEE) offers a dynamic and functional alternative to thermodilution. Analyze concordance between two TEE methods and thermodilution for cardiac output assessment. Observational concordance study in cardiovascular surgery patients that required pulmonary artery catheter. TEE cardiac output measurement at both mitral annulus (MA) and left ventricle outflow tract (LVOT) were performed. Results were compared with thermodilution. Correlation was evaluated by Lin's concordance correlation coefficient and Bland-Altman analysis. Statistical analysis was undertaken in STATA 13.0. Twenty-five patients were enrolled. Fifty two percent of patients were male, median age and ejection fraction was 63 years and 35% respectively. Median thermodilution, LVOT and MA -measured cardiac output was 3.25 L/min, 3.46 L/min and 8.4 L/min respectively. Different values between thermodilution and MA measurements were found (Lin concordance=0.071; Confidence Interval 95%=-0.009 to 0.151; Spearman's correlation=0.22) as values between thermodilution and LVOT (Lin concordance=0.232; Confidence Interval 95%=-0.12 a 0.537; Spearman's correlation 0.28). Bland-Altman analysis showed greater difference between MA measurements and thermodilution (DM=-0.408; Bland-Altman Limits=-0.809 to -0.007), than the other echocardiographic findings (DM=0.007; Bland-Altman Limits=-0.441 to 0.428). Results from cardiac output measurement by doppler and 2D-TEE on both MA and LVOT do not correlate with those obtained by thermodilution. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  17. Cerebral oxygen saturation and cardiac output during anaesthesia in sitting position for neurosurgical procedures: a prospective observational study.

    Science.gov (United States)

    Schramm, P; Tzanova, I; Hagen, F; Berres, M; Closhen, D; Pestel, G; Engelhard, K

    2016-10-01

    Neurosurgical operations in the dorsal cranium often require the patient to be positioned in a sitting position. This can be associated with decreased cardiac output and cerebral hypoperfusion, and possibly, inadequate cerebral oxygenation. In the present study, cerebral oxygen saturation was measured during neurosurgery in the sitting position and correlated with cardiac output. Perioperative cerebral oxygen saturation was measured continuously with two different monitors, INVOS ® and FORE-SIGHT ® . Cardiac output was measured at eight predefined time points using transoesophageal echocardiography. Forty patients were enrolled, but only 35 (20 female) were eventually operated on in the sitting position. At the first time point, the regional cerebral oxygen saturation measured with INVOS ® was 70 (sd 9)%; thereafter, it increased by 0.0187% min -1 (P<0.01). The cerebral tissue oxygen saturation measured with FORE-SIGHT ® started at 68 (sd 13)% and increased by 0.0142% min -1 (P<0.01). The mean arterial blood pressure did not change. Cardiac output was between 6.3 (sd 1.3) and 7.2 (1.8) litre min -1 at the predefined time points. Cardiac output, but not mean arterial blood pressure, showed a positive and significant correlation with cerebral oxygen saturation. During neurosurgery in the sitting position, the cerebral oxygen saturation slowly increases and, therefore, this position seems to be safe with regard to cerebral oxygen saturation. Cerebral oxygen saturation is stable because of constant CO and MAP, while the influence of CO on cerebral oxygen saturation seems to be more relevant. NCT01275898. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. A comparison of dobutamine and levosimendan on hepatic blood flow in patients with a low cardiac output state after cardiac surgery: a randomised controlled study.

    Science.gov (United States)

    Alvarez, J; Baluja, A; Selas, S; Otero, P; Rial, M; Veiras, S; Caruezo, V; Taboada, M; Rodriguez, I; Castroagudin, J; Tome, S; Rodriguez, A; Rodriguez, J

    2013-11-01

    Liver dysfunction due to a low cardiac output state after cardiac surgery is associated with a poor prognosis, but whether one inotrope is superior to another in improving hepatic perfusion remains uncertain. This study compared the systemic and hepatic haemodynamic effects of levosimendan to dobutamine in patients with a low cardiac output state (cardiac index flow (ml/min): 614.0±124.7, 585.9±144.8; pulsatility index: 2.02±0,28, 2.98±0.27 versus the levosimendan group: cardiac index: 3.02± 0.27, 2.98± 0.30; portal vein flow: 723.0± 143.5, 702.9±117.8; pulsatility index: 1.71±0.26, 1.73±0.27). The improvement in portal vein blood flow at 48 hours was significantly better after levosimendan than dobutamine (41% vs. 11% increment from baseline, Pflow through both the hepatic artery and portal venous system, whereas dobutamine can only improve the portal venous blood flow without vasodilating the hepatic artery.

  19. Effects of cardiac output on the onset of rocuronium-induced neuromuscular block in elderly patients.

    Science.gov (United States)

    Shiraishi, Naoki; Aono, Mayu; Kameyama, Yasuhito; Yamamoto, Mai; Kitajima, Osamu; Suzuki, Takahiro

    2018-05-21

    The aim of this study was to elucidate the relationship between the onset of rocuronium-induced neuromuscular block and arterial pressure-based cardiac output (CO) in elderly patients. Forty elderly patients aged 65-83 years were enrolled in this study. After induction of anesthesia, contractions of the adductor pollicis muscle to ulnar nerve train-of-four stimulation were acceleromyographically evaluated and 1 mg/kg rocuronium was administered following CO measurement. The correlation between onset of rocuronium action and CO was analyzed. The mean [SD] CO reduced after induction of anesthesia from 5.1 [1.8] L/min to 3.8 [1.1] L/min. The onset time of rocuronium-induced neuromuscular block was 110.3 [23.9] s (range 60-165). There was a statistically significant inverse correlation between the onset time of rocuronium and CO [onset time (s) = - 13.2·CO + 159.7, R 2  = 0.376]. In the elderly, CO influences the onset of action of rocuronium.

  20. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  1. Exercise-related cardiac arrest in cardiac rehabilitation - The ...

    African Journals Online (AJOL)

    Prescribed physical activity plays a major role in the rehabilitation of patients with coronary artery disease, and as with any other form of treatment its benefits must be weighed against its possible risks. This study attempted to establish the safety of cardiac rehabilitation as a medical intervention at the Johannesburg Cardiac ...

  2. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant

    OpenAIRE

    Matos, Lígia Neres; Guimarães, Tereza Cristina Felippe; Brandão, Marcos Antônio Gomes; Santoro, Deyse Conceição

    2012-01-01

    The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009....

  3. Children with Burn Injury Have Impaired Cardiac Output during Submaximal Exercise.

    Science.gov (United States)

    Rivas, Eric; Herndon, David N; Beck, Kenneth C; Suman, Oscar E

    2017-10-01

    Burn trauma damages resting cardiac function; however, it is currently unknown if the cardiovascular response to exercise is likewise impaired. We tested the hypothesis that, in children, burn injury lowers cardiac output (Q˙) and stroke volume (SV) during submaximal exercise. Five children with 49% ± 4% total body surface area (BSA) burned (two female, 11.7 ± 1 yr, 40.4 ± 18 kg, 141.1 ± 9 cm) and eight similar nonburned controls (five female, 12.5 ± 2 yr, 58.0 ± 17 kg, 147.3 ± 12 cm) with comparable exercise capacity (peak oxygen consumption [peak V˙O2]: 31.9 ± 11 vs 36.8 ± 8 mL O2·kg·min, P = 0.39) participated. The exercise protocol entailed a preexercise (pre-EX) rest period followed by 3-min exercise stages at 20 W and 50 W. V˙O2, HR, Q˙ (via nonrebreathing), SV (Q˙/HR), and arteriovenous O2 difference ([a-v]O2diff, Q˙/ V˙O2) were the primary outcome variables. Using a 2-way factorial ANOVA (group [G] × exercise [EX]), we found that Q˙ was approximately 27% lower in the burned than the nonburned group at 20 W of exercise (burned 5.7 ± 1.0 vs nonburned: 7.9 ± 1.8 L·min) and 50 W of exercise (burned 6.9 ± 1.6 vs nonburned 9.2 ± 3.2 L·min) (G-EX interaction, P = 0.012). SV did not change from rest to exercise in burned children but increased by approximately 24% in the nonburned group (main effect for EX, P = 0.046). Neither [a-v] O2diff nor V˙O2 differed between groups at rest or exercise, but HR response to exercise was reduced in the burn group (G-EX interaction, P = 0.004). When normalized to BSA, SV (index) was similar between groups; however, Q˙ (index) remained attenuated in the burned group (G-EX interaction, P exercise. Further investigation of hemodynamic function during exercise will provide insights important for cardiovascular rehabilitation in burned children.

  4. Estimation of international output-energy relation. Effects of alternative output measures

    International Nuclear Information System (INIS)

    Shrestha, R.M.

    2000-01-01

    This paper analyzes the output-energy relationship with alternative measures of output and energy. Our analysis rejects the hypothesis of non-diminishing returns to energy consumption when GDP at purchasing power parities is used as the output measure unlike the case with GNP at market exchange rates. This finding also holds when energy input includes the usage of both commercial and traditional fuels. 13 refs

  5. High-Intensity Interval Training Increases Cardiac Output and V˙O2max.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael A; Namm, Samantha; Fischer, Anthony; Wood, Kimi M

    2017-02-01

    Increases in maximal oxygen uptake (V˙O2max) frequently occur with high-intensity interval training (HIIT), yet the specific adaptation explaining this result remains elusive. This study examined changes in V˙O2max and cardiac output (CO) in response to periodized HIIT. Thirty-nine active men and women (mean age and V˙O2max = 22.9 ± 5.4 yr and 39.6 ± 5.6 mL·kg·min) performed HIIT and 32 men and women (age and V˙O2max = 25.7 ± 4.5 yr and 40.7 ± 5.2 mL·kg·min) were nonexercising controls (CON). The first 10 sessions of HIIT required eight to ten 60 s bouts of cycling at 90%-110% percent peak power output interspersed with 75 s recovery, followed by randomization to one of three regimes (sprint interval training (SIT), high-volume interval training (HIITHI), or periodized interval training (PER) for the subsequent 10 sessions. Before, midway, and at the end of training, progressive cycling to exhaustion was completed during which V˙O2max and maximal CO were estimated. Compared with CON, significant (P HIIT + SIT (39.8 ± 7.3 mL·kg·min to 43.6 ± 6.1 mL·kg·min), HIIT + HIITHI (41.1 ± 4.9 mL·kg·min to 44.6 ± 7.0 mL·kg·min), and HIIT + PER (39.5 ± 5.6 mL·kg·min to 44.1 ± 5.4 mL·kg·min) occurred which were mediated by significant increases in maximal CO (20.0 ± 3.1 L·min to 21.7 ± 3.2 L·min, P = 0.04). Maximal stroke volume was increased with HIIT (P = 0.04), although there was no change in maximal HR (P = 0.88) or arteriovenous O2 difference (P = 0.36). These CO data are accurate and represent the mean changes from pre- to post-HIIT across all three training groups. Increases in V˙O2max exhibited in response to different HIIT regimes are due to improvements in oxygen delivery.

  6. Omega-3 fatty acid supplementation enhances stroke volume and cardiac output during dynamic exercise.

    Science.gov (United States)

    Walser, Buddy; Stebbins, Charles L

    2008-10-01

    Docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA) have beneficial effects on cardiovascular function. We tested the hypotheses that dietary supplementation with DHA (2 g/day) + EPA (3 g/day) enhances increases in stroke volume (SV) and cardiac output (CO) and decreases in systemic vascular resistance (SVR) during dynamic exercise. Healthy subjects received DHA + EPA (eight men, four women) or safflower oil (six men, three women) for 6 weeks. Both groups performed 20 min of bicycle exercise (10 min each at a low and moderate work intensity) before and after DHA + EPA or safflower oil treatment. Mean arterial pressure (MAP), heart rate (HR), SV, CO, and SVR were assessed before exercise and during both workloads. HR was unaffected by DHA + EPA and MAP was reduced, but only at rest (88 +/- 5 vs. 83 +/- 4 mm Hg). DHA + EPA augmented increases in SV (14.1 +/- 6.3 vs. 32.3 +/- 8.7 ml) and CO (8.5 +/- 1.0 vs. 10.3 +/- 1.2 L/min) and tended to attenuate decreases in SVR (-7.0 +/- 0.6 vs. -10.1 +/- 1.6 mm Hg L(-1) min(-1)) during the moderate workload. Safflower oil treatment had no effects on MAP, HR, SV, CO or SVR at rest or during exercise. DHA + EPA-induced increases in SV and CO imply that dietary supplementation with these fatty acids can increase oxygen delivery during exercise, which may have beneficial clinical implications for individuals with cardiovascular disease and reduced exercise tolerance.

  7. Optimizing Cardiac Out-Put to Increase Cerebral Penumbral Perfusion in Large Middle Cerebral Artery Ischemic Lesion—OPTIMAL Study

    Directory of Open Access Journals (Sweden)

    Hannah Fuhrer

    2017-08-01

    Full Text Available IntroductionIn unsuccessful vessel recanalization, clinical outcome of acute stroke patients depends on early improvement of penumbral perfusion. So far, mean arterial blood pressure (MAP is the target hemodynamic parameter. However, the correlations of MAP to cardiac output (CO and cerebral perfusion are volume state dependent. In severe subarachnoid hemorrhage, optimizing CO leads to a reduction of delayed ischemic neurological deficits and improvement of clinical outcome. This study aims to investigate the effect of standard versus advanced cardiac monitoring with optimization of CO on the clinical outcome in patients with large ischemic stroke.Methods and analysisThe OPTIMAL study is a prospective, multicenter, open, into two arms (1:1 randomized, controlled trial. Sample size estimate: sample sizes of 150 for each treatment group (300 in total ensure an 80% power to detect a difference of 16% of a dichotomized level of functional clinical outcome at 3 months at a significance level of 0.05. Study outcomes: the primary endpoint is the functional outcome at 3 months. The secondary endpoints include functional outcome at 6 months follow-up, and complications related to hemodynamic monitoring and therapies.DiscussionThe results of this trial will provide data on the safety and efficacy of advanced hemodynamic monitoring on clinical outcome.Ethics and disseminationThe trial was approved by the leading ethics committee of Freiburg University, Germany (438/14, 2015 and the local ethics committees of the participating centers. The study is performed in accordance with the Declaration of Helsinki and the guidelines of Good Clinical Practice. It is registered in the German Clinical Trial register (DRKS; DRKS00007805. Dissemination will include submission to peer-reviewed professional journals and presentation at congresses. Hemodynamic monitoring may be altered in a specific stroke patient cohort if the study shows that advanced monitoring is

  8. The effect of halothane on the distribution of cardiac output and organ blood flows in the hemorrhagic, hypotensive dog

    International Nuclear Information System (INIS)

    Ahlgren, I.; Aronsen, K.F.; Bjoerkman, I.

    1978-01-01

    Halothane was given to dogs which had been bled to an arterial mean blood pressure of 60 mmHg, and the circulatory effects were studied with the aid of the radioactive microsphere technique. The cardiac output and coronary blood flow were well maintained, whereas the arterial mean blood pressure was slightly, and the stroke volume markedly increased, indicating an improved heart function. The blood flows to the brain, lungs, liver and kidneys were well preserved throughout the anesthesia. The effect of retransfusing the withdrawn blood was also studied, and it resulted in an increased cardiac output, arterial mean blood pressure and increased blood flows to the heart, lungs, spleen, bowel and liver. (author)

  9. Effect of heat stress on cardiac output and systemic vascular conductance during simulated hemorrhage to presyncope in young men

    DEFF Research Database (Denmark)

    Ganio, Matthew S; Overgaard, Morten; Seifert, Thomas

    2012-01-01

    During moderate actual or simulated hemorrhage, as cardiac output decreases, reductions in systemic vascular conductance (SVC) maintain mean arterial pressure (MAP). Heat stress, however, compromises the control of MAP during simulated hemorrhage, and it remains unknown whether this response is due...... to a persistently high SVC and/or a low cardiac output. This study tested the hypothesis that an inadequate decrease in SVC is the primary contributing mechanism by which heat stress compromises blood pressure control during simulated hemorrhage. Simulated hemorrhage was imposed via lower body negative pressure...... normothermic is no longer adequate during a heat-stressed-simulated hemorrhage. The absence of a decrease in SVC at a time of profound reductions in MAP suggests that inadequate control of vascular conductance is a primary mechanism compromising blood pressure control during these conditions....

  10. Study on cardiac output in children with orthostatic disturbances measured by the external dilution method with a radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, K [Nippon Medical School, Tokyo

    1975-04-01

    As one of the studies on circulation dynamics which possibly contributed to orthostatic disturbance, application to children of the external measurement of cardiac output with /sup 131/I labeled human serum albumin was examined. The effect of orthostatic load was then studied by this method on the children with orthostatic disturbances and the patients improving from other diseases, and the following results were obtained: (1) As in the external method with radioisotope, the head of the scintillation detector was easily oriented, and the diversion of orientation was examined by circulation dilution curve, and the cardiac output was easily and safely measured without causing severe pain to the subjects. This method was performed on 40 children in the recumbent position and 27 in orthostatic load, and it was confirmed that the method was fully applicable to the pediatric field. (2) In half of the 20 patients with orthostatic disturbances and 20 control subjects, the cardiac index in the recumbent position was between 3 l/min/m/sup 2/ and 5 l/min/m/sup 2/. Mean cardiac index was 4.45 l/min/m/sup 2/ in male children, while 4.72 l/min/m/sup 2/ in female children. This mean value was the same or a little higher than the reported adult value.

  11. Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output.

    Science.gov (United States)

    Tibby, S M; Hatherill, M; Murdoch, I A

    2000-06-01

    To ascertain if cardiac output (CO) could be derived from blood flow velocity measured in the descending aorta of ventilated children by transesophageal Doppler ultrasonography (TED) without the need for direct aortic cross sectional area measurement, and to evaluate the ability of TED to follow changes in CO when compared with femoral artery thermodilution. Prospective, comparison study. A 16-bed pediatric intensive care unit of a university hospital. A total of 100 ventilated infants and children aged 4 days to 18 yrs (median age, 27 months). Diagnoses included postcardiac surgery (n = 58), sepsis/multiple organ failure (n = 32), respiratory disease (n = 5), and other (n = 5). A total of 55 patients were receiving inotropes or vasodilators. When patients were hemodynamically stable, a TED probe was placed into the distal esophagus to obtain optimal signal, and minute distance (MD) was recorded. Five consecutive MD measurements were made concurrently with five femoral artery thermodilution measurements, and the concurrent measurements were averaged. CO was then manipulated by fluid administration or inotrope adjustment, and the readings were repeated. Femoral artery thermodilution CO ranged from 0.32 to 9.19 L/min, (median, 2.46 L/min), and encompassed a wide range of high and low flow states. Theoretical consideration revealed the optimal TED estimate for CO to be (MD x patient height2 x 10(-7)). Linear regression analysis yielded a power function model such that: estimated CO = 1.158 x (MD x height2 x 10(-7))(0.785), r2 = 0.879, standard error of the estimate = 0.266. Inclusion of a correction factor for potential changes in aortic cross-sectional area with hypo- and hypertension did not appreciably improve the predictive value of the model. MD was able to follow percentage changes in CO, giving a mean bias of 0.87% (95% confidence interval -0.85% to 2.59%), and limits of agreement of +/- 16.82%. The median coefficient of variation for MD was 3.3%. TED provides

  12. Effect of hemorrhage on cardiac output, vasopressin, aldosterone, and diuresis during immersion in men

    Science.gov (United States)

    Greenleaf, J. E.; Simanonok, K.; Bernauer, E. M.; Wade, C. E.; Keil, L. C.

    1992-01-01

    The purpose of this research was to test the hypotesis that a reduction in blood volume would attenuate or eliminate immersion-induced increases in cardiac output (Q(sub co)) and urine excretion, and to investigate accompanying vasoactive and fluid-electrolyte hormonal responses. Eight men (19-23 yr) were supine during a 2-hr control period in air, and then sat for 5-hr test periods in air at 20 C (dry control, DC); water at 34.5 C (wet control, WC); and water (34.5 C) after hemorrhage (WH) of 14.8 plus or minus 0.3 percent of their blood volume. Blood volume was -11.6 plus or minus 0.6 percent at immersion (time 0). Mean (bar-X hrs 1-5) Q(sub co) was unchanged in WC (5.3 plus or minus 0.01 l/min) and in WH (4.5 plus or minus 0.1 l/min), but decreased (P less than 0.05) in DC to 3.6 plus or minus 0.1 l/min. Mean urine excretion rates were 1.0 plus or minus 0.2 ml/min for DC and 1.1 plus or minus 0.2 ml/min for WH; both were lower (P less than 0.05) than that for WC of 2.0 plus or minus 0.4 ml/min. Plasma (Na+) and (Osm) were unchanged in all experiments. Mean plasma vasopressin (PVP) (bar-X hrs 1-5) was 1.1 plus or minus 0.1 pg/ml in WC, and higher (P less than 0.05) in DC (2.1 plus or minus 0.2 pg/ml)and WH (2.1 plus or minus 0.1 pg/ml); it was unchanged during air and water test periods. Thus, hemorrhage attenuated the immersion-induced increase in Q(sub co), eliminated the WC diuresis, maintained plasma renin activity and PVP at DC levels and did not change immersion-induced aldosterone suppression; the osmotic diuresis during control immersion is apparently not due to either aldosterone suppression or vasopressin suppression.

  13. The accuracy of PiCCO® in measuring cardiac output in patients under therapeutic hypothermia: Comparison with transthoracic echocardiography.

    Science.gov (United States)

    Souto Moura, T; Aguiar Rosa, S; Germano, N; Cavaco, R; Sequeira, T; Alves, M; Papoila, A L; Bento, L

    2018-03-01

    Invasive cardiac monitoring using thermodilution methods such as PiCCO® is widely used in critically ill patients and provides a wide range of hemodynamic variables, including cardiac output (CO). However, in post-cardiac arrest patients subjected to therapeutic hypothermia, the low body temperature possibly could interfere with the technique. Transthoracic Doppler echocardiography (ECHO) has long proved its accuracy in estimating CO, and is not influenced by temperature changes. To assess the accuracy of PiCCO® in measuring CO in patients under therapeutic hypothermia, compared with ECHO. Thirty paired COECHO/COPiCCO measurements were analyzed in 15 patients subjected to hypothermia after cardiac arrest. Eighteen paired measurements were obtained at under 36°C and 12 at ≥36°C. A value of 0.5l/min was considered the maximum accepted difference between the COECHO and COPiCCO values. Under conditions of normothermia (≥36°C), the mean difference between COECHO and COPiCCO was 0.030 l/min, with limits of agreement (-0.22, 0.28) - all of the measurements differing by less than 0.5 l/min. In situations of hypothermia (<36°C), the mean difference in CO measurements was -0.426 l/min, with limits of agreement (-1.60, 0.75), and only 44% (8/18) of the paired measurements fell within the interval (-0.5, 0.5). The calculated temperature cut-off point maximizing specificity was 35.95°C: above this temperature, specificity was 100%, with a false-positive rate of 0%. The results clearly show clinically relevant discordance between COECHO and COPiCCO at temperatures of <36°C, demonstrating the inaccuracy of PiCCO® for cardiac output measurements in hypothermic patients. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. The use of cardiac output monitoring to guide the administration of intravenous fluid during hyperthermic intraperitoneal chemotherapy.

    Science.gov (United States)

    Thanigaimani, K; Mohamed, F; Cecil, T; Moran, B J; Bell, J

    2013-12-01

    The optimal strategy for intravenous (IV) fluid management during administration of hyperthermic intraperitoneal chemotherapy (HIPEC) is unclear. In this prospective study we describe the use of a LiDCOrapid™ (LiDCO, Cambridge, UK) cardiac output monitor to guide IV fluid management during cytoreductive surgery (CRS) with HIPEC. The aim of this study was to determine whether cardiac output monitoring will allow close maintenance of physiological parameters during the HIPEC phase. Twenty-five patients who underwent CRS combined with HIPEC were included in the study. Intra-operative IV fluid boluses were titrated using parameters measured by the LiDCOrapid™ monitor. Stroke volume variation was maintained below 10% with fluid boluses and mean arterial pressure was maintained within 20% of the baseline figure with vasopressors. There was no significant change in heart rate and cardiac output. The systemic vascular resistance dropped from an average of 966 dyn.s/cm-5 to 797 dyn s/cm(5) at 60 min during the HIPEC phase (P = 0.62) despite an increase in the dose of phenylepherine. The average total volume of fluid given was 748 ml in the first 30 min and 630 ml in the second 30 min with an average urine output of 307 and 445 ml, respectively. The change in lactate levels was not statistically or clinically significant. LiDCOrapid™ is an effective noninvasive tool for guiding fluid management in this population. It allows the anaesthesiologist to maintain tight control of essential physiological parameters during a phase of the procedure in which there is a risk of renal injury. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  15. Cardiac output response to changes of the atrioventricular delay in different body positions and during exercise in patients receiving cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Ståhlberg, Marcus; Damgaard, Morten; Norsk, Peter

    2009-01-01

    AIMS: The aim of this study was to study the haemodynamic effect of atrioventricular delay (AVD) modifications within a narrow range in different body positions and during exercise in patients receiving cardiac resynchronization therapy (CRT). METHODS: The previously optimized AVD was shortened...... and prolonged by 40 ms in 27 CRT patients and 9 controls without heart failure. Cardiac output (CO) was measured by inert gas rebreathing (Innocor) as the average over different body positions (left-lateral, supine, sitting, standing, and exercise). In eight CRT patients with an implantable haemodynamic monitor......, the estimated pulmonary artery diastolic pressure (ePAD) was analysed. RESULTS: The magnitude of CO response to AVD changes was greater in CRT patients than in controls (0.25 vs. 0.20 L/min, Psize (r=0...

  16. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study.

    Science.gov (United States)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E; Jensen, Jan S; Galatius, Søren; Frøbert, Ole

    2014-09-16

    Despite 5-7 months of physical inactivity during hibernation, brown bears (Ursus arctos) are able to cope with physiological conditions that would be detrimental to humans. During hibernation, the tissue metabolic demands fall to 25% of the active state. Our objective was to assess cardiac function associated with metabolic depression in the hibernating vs. active states in free-ranging Scandinavian brown bears. We performed echocardiography on seven free-ranging brown bears in Dalarna, Sweden, anesthetized with medetomidine-zolazepam-tiletamine-ketamine during winter hibernation in February 2013 and with medetomidine-zolazepam-tiletamine during active state in June 2013. We measured cardiac output noninvasively using estimates of hemodynamics obtained by pulsed wave Doppler echocardiography and 2D imaging. Comparisons were made using paired T-tests. During hibernation, all hemodynamic indices were significantly decreased (hibernating vs. active state): mean heart rate was 26.0 (standard deviation (SD): 5.6) beats per min vs. 75.0 (SD: 17.1) per min (P=0.002), mean stroke volume 32.3 (SD: 5.2) ml vs. 47.1 (SD: 7.9) ml (P=0.008), mean cardiac output 0.86 (SD: 0.31) l/min vs. 3.54 (SD: 1.04) l/min (P=0.003), and mean cardiac index 0.63 (SD: 0.21) l/min/kg vs. 2.45 (SD: 0.52) l/min/ m2 (Pbears during hibernation, despite the absence of atrial arrhythmias and valvular disease. Free-ranging brown bears demonstrate hemodynamics comparable to humans during active state, whereas during hibernation, we documented extremely low-flow hemodynamics. Understanding these physiological changes in bears may help to gain insight into the mechanisms of cardiogenic shock and heart failure in humans.

  17. The correlation between the first heart sound and cardiac output as measured by using digital esophageal stethoscope under anaesthesia.

    Science.gov (United States)

    Duck Shin, Young; Hoon Yim, Kyoung; Hi Park, Sang; Wook Jeon, Yong; Ho Bae, Jin; Soo Lee, Tae; Hwan Kim, Myoung; Jin Choi, Young

    2014-03-01

    The use of an esophageal stethoscope is a basic heart sounds monitoring procedure performed in patients under general anesthesia. As the size of the first heart sound can express the left ventricle function, its correlation with cardiac output should be investigated. The aim of this study was to investigate the effects of cardiac output (CO) on the first heart sound (S1) amplitude. Methods : Six male beagles were chosen. The S1 was obtained with the newly developed esophageal stethoscope system. CO was measured using NICOM, a non-invasive CO measuring device. Ephedrine and beta blockers were administered to the subjects to compare changes in figures, and the change from using an inhalation anesthetic was also compared. The S1 amplitude displayed positive correlation with the change rate of CO (r = 0.935, p < 0.001). The heart rate measured using the esophageal stethoscope and ECG showed considerably close figures through the Bland-Altman plot and showed a high positive correlation (r = 0.988, p < 0,001). In beagles, the amplitude of S1 had a significant correlation with changes in CO in a variety of situations.

  18. Reduced peripheral arterial blood flow with preserved cardiac output during submaximal bicycle exercise in elderly heart failure

    Directory of Open Access Journals (Sweden)

    Leng Xiaoyan

    2009-11-01

    Full Text Available Abstract Background Older heart failure (HF patients exhibit exercise intolerance during activities of daily living. We hypothesized that reduced lower extremity blood flow (LBF due to reduced forward cardiac output would contribute to submaximal exercise intolerance in older HF patients. Methods and Results Twelve HF patients both with preserved and reduced left ventricular ejection fraction (LVEF (aged 68 ± 10 years without large (aorta or medium sized (iliac or femoral artery vessel atherosclerosis, and 13 age and gender matched healthy volunteers underwent a sophisticated battery of assessments including a peak exercise oxygen consumption (peak VO2, b physical function, c cardiovascular magnetic resonance (CMR submaximal exercise measures of aortic and femoral arterial blood flow, and d determination of thigh muscle area. Peak VO2 was reduced in HF subjects (14 ± 3 ml/kg/min compared to healthy elderly subjects (20 ± 6 ml/kg/min (p = 0.01. Four-meter walk speed was 1.35 ± 0.24 m/sec in healthy elderly verses 0.98 ± 0.15 m/sec in HF subjects (p p ≤ 0.03. Conclusion During CMR submaximal bike exercise in the elderly with heart failure, mechanisms other than low cardiac output are responsible for reduced lower extremity blood flow.

  19. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.

    Science.gov (United States)

    Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria

    2014-02-01

    To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the

  20. Cardiac output by pulse contour analysis does not match the increase measured by rebreathing during human spaceflight.

    Science.gov (United States)

    Hughson, Richard L; Peterson, Sean D; Yee, Nicholas J; Greaves, Danielle K

    2017-11-01

    Pulse contour analysis of the noninvasive finger arterial pressure waveform provides a convenient means to estimate cardiac output (Q̇). The method has been compared with standard methods under a range of conditions but never before during spaceflight. We compared pulse contour analysis with the Modelflow algorithm to estimates of Q̇ obtained by rebreathing during preflight baseline testing and during the final month of long-duration spaceflight in nine healthy male astronauts. By Modelflow analysis, stroke volume was greater in supine baseline than seated baseline or inflight. Heart rate was reduced in supine baseline so that there were no differences in Q̇ by Modelflow estimate between the supine (7.02 ± 1.31 l/min, means ± SD), seated (6.60 ± 1.95 l/min), or inflight (5.91 ± 1.15 l/min) conditions. In contrast, rebreathing estimates of Q̇ increased from seated baseline (4.76 ± 0.67 l/min) to inflight (7.00 ± 1.39 l/min, significant interaction effect of method and spaceflight, P < 0.001). Pulse contour analysis utilizes a three-element Windkessel model that incorporates parameters dependent on aortic pressure-area relationships that are assumed to represent the entire circulation. We propose that a large increase in vascular compliance in the splanchnic circulation invalidates the model under conditions of spaceflight. Future spaceflight research measuring cardiac function needs to consider this important limitation for assessing absolute values of Q̇ and stroke volume. NEW & NOTEWORTHY Noninvasive assessment of cardiac function during human spaceflight is an important tool to monitor astronaut health. This study demonstrated that pulse contour analysis of finger arterial blood pressure to estimate cardiac output failed to track the 46% increase measured by a rebreathing method. These results strongly suggest that alternative methods not dependent on pulse contour analysis are required to track cardiac function in spaceflight

  1. Influence of water immersion, water gymnastics and swimming on cardiac output in patients with heart failure.

    Science.gov (United States)

    Schmid, Jean-Paul; Noveanu, Markus; Morger, Cyrill; Gaillet, Raymond; Capoferri, Mauro; Anderegg, Matthias; Saner, Hugo

    2007-06-01

    Whole-body water immersion leads to a significant shift of blood from the periphery to the intrathoracic circulation, followed by an increase in central venous pressure and heart volume. In patients with severely reduced left ventricular function, this hydrostatically induced volume shift might overstrain the cardiovascular adaptive mechanisms and lead to cardiac decompensation. To assess the haemodynamic response to water immersion, gymnastics and swimming in patients with chronic heart failure (CHF). 10 patients with compensated CHF (62.9 (6.3) years, ejection fraction 31.5% (4.1%), peak oxygen consumption (Vo(2)) 19.4 (2.8) ml/kg/min), 10 patients with coronary artery disease (CAD) but preserved left ventricular function (57.2 (5.6) years, ejection fraction 63.9% (5.5%), peak Vo(2) 28 (6.3) ml/kg/min), and 10 healthy controls (32.8 (7.2) years, peak Vo(2) 45.6 (6) ml/kg/min) were examined. Haemodynamic response to thermoneutral (32 degrees C) water immersion and exercise was measured using a non-invasive foreign gas rebreathing method during stepwise water immersion, water gymnastics and swimming. Water immersion up to the chest increased cardiac index by 19% in controls, by 21% in patients with CAD and by 16% in patients with CHF. Although some patients with CHF showed a decrease of stroke volume during immersion, all subjects were able to increase cardiac index (by 87% in healthy subjects, by 77% in patients with CAD and by 53% in patients with CHF). Vo(2) during swimming was 9.7 (3.3) ml/kg/min in patients with CHF, 12.4 (3.5) ml/kg/min in patients with CAD and 13.9 (4) ml/kg/min in controls. Patients with severely reduced left ventricular function but stable clinical conditions and a minimal peak Vo(2) of at least 15 ml/kg/min during a symptom-limited exercise stress test tolerate water immersion and swimming in thermoneutral water well. Although cardiac index and Vo(2) are lower than in patients with CAD with preserved left ventricular function and controls

  2. Plasma volume expansion does not increase maximal cardiac output or VO2 max in lowlanders acclimatized to altitude

    DEFF Research Database (Denmark)

    Calbet, José A L; Rådegran, Göran; Boushel, Robert Christopher

    2004-01-01

    liter of 6% dextran 70 (BV = 6.32 +/- 0.34 liters). PV expansion had no effect on Qmax, maximal O2 consumption (VO2), and exercise capacity. Despite maximal systemic O2 transport being reduced 19% due to hemodilution after PV expansion, whole body VO2 was maintained by greater systemic O2 extraction (P...... VO2 during exercise regardless of PV. Pulmonary ventilation, gas exchange, and acid-base balance were essentially unaffected by PV expansion. Sea......With altitude acclimatization, blood hemoglobin concentration increases while plasma volume (PV) and maximal cardiac output (Qmax) decrease. This investigation aimed to determine whether reduction of Qmax at altitude is due to low circulating blood volume (BV). Eight Danish lowlanders (3 females, 5...

  3. Call-related factors influencing output power from mobile phones.

    Science.gov (United States)

    Hillert, Lena; Ahlbom, Anders; Neasham, David; Feychting, Maria; Järup, Lars; Navin, Roshan; Elliott, Paul

    2006-11-01

    Mobile phone use is increasing but there is also concern for adverse health effects. Well-designed prospective studies to assess several health outcomes are required. In designing a study of mobile phone use, it is important to assess which factors need to be considered in classifying the exposure to radiofrequency fields (RF). A pilot study was performed in Sweden and in the UK 2002 to 2003 to test the feasibility of recruiting a cohort of mobile phone users from a random population sample and from mobile phone subscription lists for a prospective study. As one part of this pilot study, different factors were evaluated regarding possible influence on the output power of the phones. By local switch logging, information on calls made from predefined subscriptions or dedicated handsets were obtained and the output power of phones during calls made indoors and outdoors, in moving and stationary mode, and in rural as well in urban areas were compared. In this experiment, calls were either 1, 1.5 or 5 min long. The results showed that high mobile phone output power is more frequent in rural areas whereas the other factors (length of call, moving/stationary, indoor/outdoor) were of less importance. Urban and rural area should be considered in an exposure index for classification of the exposure to RF from mobile phones and may be assessed by first base station during mobile phone calls or, if this information is not available, possibly by using home address as a proxy.

  4. Do interindividual differences in cardiac output during submaximal exercise explain differences in exercising muscle oxygenation and ratings of perceived exertion?

    Science.gov (United States)

    Bentley, Robert F; Jones, Joshua H; Hirai, Daniel M; Zelt, Joel T; Giles, Matthew D; Raleigh, James P; Quadrilatero, Joe; Gurd, Brendon J; Neder, J Alberto; Tschakovsky, Michael E

    2018-01-01

    Considerable interindividual differences in the Q˙-V˙O2 relationship during exercise have been documented but implications for submaximal exercise tolerance have not been considered. We tested the hypothesis that these interindividual differences were associated with differences in exercising muscle deoxygenation and ratings of perceived exertion (RPE) across a range of submaximal exercise intensities. A total of 31 (21 ± 3 years) healthy recreationally active males performed an incremental exercise test to exhaustion 24 h following a resting muscle biopsy. Cardiac output (Q˙ L/min; inert gas rebreathe), oxygen uptake (V˙O2 L/min; breath-by-breath pulmonary gas exchange), quadriceps saturation (near infrared spectroscopy) and exercise tolerance (6-20; Borg Scale RPE) were measured. The Q˙-V˙O2 relationship from 40 to 160 W was used to partition individuals post hoc into higher (n = 10; 6.3 ± 0.4) versus lower (n = 10; 3.7 ± 0.4, P exercise (all P > 0.4). Lower cardiac responders had greater leg (P = 0.027) and whole body (P = 0.03) RPE only at 185 W, but this represented a higher %peak V˙O2 in lower cardiac responders (87 ± 15% vs. 66 ± 12%, P = 0.005). Substantially lower Q˙-V˙O2 in the lower responder group did not result in altered RPE or exercising muscle deoxygenation. This suggests substantial recruitment of blood flow redistribution in the lower responder group as part of protecting matching of exercising muscle oxygen delivery to demand. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  5. Preferential cephalic redistribution of left ventricular cardiac output during therapeutic hypothermia for perinatal hypoxic-ischemic encephalopathy.

    Science.gov (United States)

    Hochwald, Ori; Jabr, Mohammad; Osiovich, Horacio; Miller, Steven P; McNamara, Patrick J; Lavoie, Pascal M

    2014-05-01

    To determine the relationship between left ventricular cardiac output (LVCO), superior vena cava (SVC) flow, and brain injury during whole-body therapeutic hypothermia. Sixteen newborns with moderate or severe hypoxic-ischemic encephalopathy were studied using echocardiography during and immediately after therapeutic hypothermia. Measures were also compared with 12 healthy newborns of similar postnatal age. Newborns undergoing therapeutic hypothermia also had cerebral magnetic resonance imaging as part of routine clinical care on postnatal day 3-4. LVCO was markedly reduced (mean ± SD 126 ± 38 mL/kg/min) during therapeutic hypothermia, whereas SVC flow was maintained within expected normal values (88 ± 27 mL/kg/min) such that SVC flow represented 70% of the LVCO. The reduction in LVCO during therapeutic hypothermia was mainly accounted by a reduction in heart rate (99 ± 13 vs 123 ± 17 beats/min; P newborns without brain injury (P = .013). Newborns with perinatal hypoxic-ischemic encephalopathy showed a preferential systemic-to-cerebral redistribution of cardiac blood flow during whole-body therapeutic hypothermia, which may reflect a lack of cerebral vascular adaptation in newborns with more severe brain injury. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Measurement of cardiac output in children by pressure-recording analytical method.

    Science.gov (United States)

    Urbano, Javier; López, Jorge; González, Rafael; Solana, María José; Fernández, Sarah N; Bellón, José M; López-Herce, Jesús

    2015-02-01

    We evaluated two pressure-recording analytical method (PRAM) software versions (v.1 and v.2) to measure cardiac index (CI) in hemodynamically stable critically ill children and investigate factors that influence PRAM values. The working hypothesis was that PRAM CI measurements would stay within normal limits in hemodynamically stable patients. Ninety-five CI PRAM measurements were analyzed in 47 patients aged 1-168 months. Mean CI was 4.1 ± 1.4 L/min/m(2) (range 2.0-7.0). CI was outside limits defined as normal (3-5 L/min/m(2)) in 53.7% of measurements (47.8% with software v.1 and 69.2% with software v.2, p = 0.062). Moreover, 14.7% of measurements were below 2.5 L/min/m(2), and 13.6% were above 6 L/min/m(2). CI was significantly lower in patients with a clearly visible dicrotic notch than in those without (3.7 vs. 4.6 L/min/m(2), p = 0.004) and in children with a radial arterial catheter (3.5 L/min/m(2)) than in those with a brachial (4.4 L/min/m(2), p = 0.021) or femoral catheter (4.7 L/min/m(2), p = 0.005). By contrast, CI was significantly higher in children under 12 months (4.2 vs. 3.6 L/min/m(2), p = 0.034) and weighing under 10 kg (4.2 vs. 3.6 L/min/m(2), p = 0.026). No significant differences were observed between cardiac surgery patients and the rest of children. A high percentage of CI measurements registered by PRAM were outside normal limits in hemodynamically stable, critically ill children. CI measured by PRAM may be influenced by the age, weight, location of catheter, and presence of a dicrotic notch.

  7. Elite athletes experiences with risk related to cardiac screening

    DEFF Research Database (Denmark)

    Christensen, Jonas Schmidt; Thing, Lone Friis

    Society of Cardiology as well as major sports federations such as the International Olympic Committee, however, these recommendations seem to be based on an inadequate empirical foundation, just as the costs of performing cardiac screening on a larger scale seem out of proportion. Additionally, the field...... perspective on risk (Foucault 1988). For most elite athletes participation in cardiac screening is done out of a wish to obtain an acquittal from risks. Symptomatic of the risk society cardiac screening can from an athlete perspective at the same time be seen as an attempt to gain control over......Elite Athletes experiences with risks related to Cardiac Screening Jonas Schmidt Christensen1, Lone Friis Thing1 1University of Copenhagen - Department of Nutrition, Exercise and Sports (NEXS), Cardiac screening of elite athletes are recommended by both the American Heart Association & the European...

  8. Oral Consumption of Vitamin K2 for 8 Weeks Associated With Increased Maximal Cardiac Output During Exercise.

    Science.gov (United States)

    McFarlin, Brian K; Henning, Andrea L; Venable, Adam S

    2017-07-01

    Background • Vitamin K1 and K2 are not typically common in a Western diet because they are found in a variety of fermented foods. Vitamin K2 in particular has been demonstrated to restore mitochondrial function and has a key role in production of mitochondrial adenosine triphosphate. Thus, it is reasonable to speculate that dietary supplementation with vitamin K2 could increase the function of muscle with high mitochondrial content (ie, skeletal and cardiac muscle). Objective • The purpose of this study was to determine if 8 wk of dietary supplementation with Vitamin K2 could alter cardiovascular responses to a graded cycle ergometer test. Design • The study was a randomized controlled trial. Setting • The study took place in the Applied Physiology Laboratory of the Department of Biological Sciences at the University of North Texas (Denton, TX, USA). Participants • Participants were aerobically trained males and female athletes (N = 26). Intervention • Participants were randomly assigned either to a control group that received a rice flour placebo or to an intervention group that received vitamin K2. For weeks 1 to 4, participants received 300 mg/d; for weeks 5 to 8, they received 150 mg/d. Subjects assigned to the control group received similar doses to mirror the intervention group. Subjects consumed the supplements during an 8-wk period while they maintained their typical exercise habits. Outcome Measures • At baseline and postintervention, participants completed a standard, graded exercise test on an electronically braked cycle ergometer. Before the test, participants were fitted with a mouth piece, and their oxygen consumption, carbon dioxide production, respiratory rate, and respiratory exchange ratio were measured. In addition, participants were fitted with skin-mounted electrodes that measured noninvasive cardiac output, stroke volume, and heart rate. To assess the cumulative exercise change, an area-under-the-curve (AUC) value was calculated

  9. The outcome of anaesthesia related cardiac arrest in a

    Directory of Open Access Journals (Sweden)

    O.O. Adekola

    2016-07-01

    Conclusion: Anaesthesia related cardiac arrest and mortality were linked to cardiovascular depression from halothane overdose in our institution. The burden can be reduced by improving on establishing standard monitoring in the perioperative period, and a team approach to patients care.

  10. Increased cardiac output and maximal oxygen uptake in response to ten sessions of high intensity interval training.

    Science.gov (United States)

    Astorino, Todd A; Edmunds, Ross M; Clark, Amy; King, Leesa; Gallant, Rachael M; Namm, Samantha; Fischer, Anthony; Wood, Kimi A

    2018-01-01

    Increases in maximal oxygen uptake (VO2max) are widely reported in response to completion of high intensity interval training (HIIT), yet the mechanism explaining this result is poorly understood. This study examined changes in VO2max and cardiac output (CO) in response to 10 sessions of low-volume HIIT. Participants included 30 active men and women (mean age and VO2max=22.9±5.4 years and 39.6±5.6 mL/kg/min) who performed HIIT and 30 men and women (age and VO2max=25.7±4.5 years and 40.7±5.2 mL/kg/min) who served as non-exercising controls (CON). High intensity interval training consisted of 6-10 s bouts of cycling per session at 90-110 percent peak power output (PPO) interspersed with 75 s recovery. Before and after training, progressive cycling to exhaustion was completed during which CO, stroke volume (SV), and heart rate (HR) were estimated using thoracic impedance. To confirm VO2max attainment, a verification test was completed after progressive cycling at a work rate equal to 110%PPO. Data demonstrated significant improvements in VO2max (2.71±0.63 L/min to 2.86±0.63 L/min, Psessions of HIIT is due to improvements in oxygen delivery.

  11. Cardiac output by Doppler echocardiography in the premature baboon: Comparison with radiolabeled microspheres

    International Nuclear Information System (INIS)

    Kinsella, J.P.; Morrow, W.R.; Gerstmann, D.R.; Taylor, A.F.; deLemos, R.A.

    1991-01-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). The authors conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress

  12. The definition of exertion-related cardiac events.

    Science.gov (United States)

    Rai, M; Thompson, P D

    2011-02-01

    Vigorous physical activity increases the risk of sudden cardiac death (SCD) and acute myocardial infarction (AMI) but there is no standard definition as to what constitutes an exertion-related cardiac event, specifically the time interval between physical exertion and cardiac event. A systematic review of studies related to exertion-related cardiac events was performed and the time interval between exertion and the event or the symptoms leading to the event was looked for in all the articles selected for inclusion. A total of 12 of 26 articles "suggested" or "defined" exertion-related events as those events whose symptoms started during or within 1 h of exertion. Others used definitions of 0.5 h, 2 h, "during exertion", "during or immediately post exertion" and "during or within several hours after exertion". It is suggested, therefore, that the definition of an exertion-related cardiac event be established as a cardiac event in which symptoms started during or within 1 h of physical exertion.

  13. RELATION BETWEEN PREECLAMPSIA AND CARDIAC ENZYMES

    Directory of Open Access Journals (Sweden)

    Rubina Aziz

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: Preeclampsia affects about 5-10% of all pregnancies and is a major cause of maternal, fetal and neonatal mortality and morbidity. The cardiovascular system undergoes a host of changes in association with development of preeclampsia. LDH is a useful biochemical marker that reflects the severity of the occurrence of preeclampsia.    METHOD AND MATERIALS: One hundred pregnant women were selected for this study, 50 normal pregnant women as controls and 50 preeclamptic women as the study group.  Cardiac enzymes (serum LDH, serum AST, serum CK and serum CKMB of these women were analyzed.    RESULTS: Mean Serum LDH and mean serum AST concentrations were significantly higher in preeclamptic patients compared to normal pregnant women (348.34 ± 59.17 vs. 255.92 ± 43.26, P < 0.01 and (34.32 ± 10.37 vs. 22.06 ± 5.10, P < 0.01 respectively.     CONCLUSION: LDH and AST may be increased due to liver damage. This endothelial vascular damage is the main cause in the occurrence of preeclampsia. Higher levels of LDH and AST are very useful markers to identify the occurrence of preeclampsia.      Keywords: LDH, Preeclampsia, AST, Cardiac Enzymes.

  14. Myoglobinaemia in relation to cardiac necrosis

    Energy Technology Data Exchange (ETDEWEB)

    McComb, J M

    1981-01-01

    An evaluation of the usefulness of estimation of the serum myoglobin in the detection of myocardial necrosis was made in patients with suspected acute ischemic heart disease and in patients in whom elective cardiac catheterization was performed. Measurement of serum myoglobin, by radioimmunoassay, in patients admitted with suspected acute myocardial infarction, suggested that a raised serum myoglobin level was a sensitive indicator of myocardial necrosis. It also showed that the serum myoglobin rose to abnormal levels before the serum creatine kinase. A study of 70 consecutive patients confirmed that the serum myoglobin level is a sensitive indicator of acute myocardial infarction and showed that its sensitivity was greater, and its specificity similar to that of serum creatine kinase. This study allowed calculation of a predictive index for the diagnosis of acute myocardial infarction from the serum myoglobin and serum creatine kinase six hours after the onset of symptoms. The use of a single myoglobin measurement in 114 patients admitted to a coronary care unit was then studied. The proposition that myocardial damage might results from cardiac catheterization was investigated in 115 patients.

  15. The Higher the Insulin Resistance the Lower the Cardiac Output in Men with Type 1 Diabetes During the Maximal Exercise Test.

    Science.gov (United States)

    Niedzwiecki, Pawel; Naskret, Dariusz; Pilacinski, Stanislaw; Pempera, Maciej; Uruska, Aleksandra; Adamska, Anna; Zozulinska-Ziolkiewicz, Dorota

    2017-06-01

    The aim of this study was to assess the hemodynamic parameters analyzed in bioimpedance cardiography during maximal exercise in patients with type 1 diabetes differing in insulin resistance. The study group consisted of 40 men with type 1 diabetes. Tissue sensitivity to insulin was assessed on the basis of the glucose disposal rate (GDR) analyzed during hyperinsulinemic-euglycemic clamp. Patients were divided into groups with GDR insulin sensitivity) and GDR ≥4.5 mg/kg/min (G2 group-higher insulin sensitivity). During the exercise test, the heart rate, systolic volume, cardiac output, cardiac index were measured by the impedance meter (PhysioFlow). Compared with the G2 group, the G1 group had a lower cardiac output (CO): during exercise 8.6 (IQR 7.7-10.0) versus 12.8 (IQR 10.8-13.7) L/min; P insulin resistance is associated with cardiac hemodynamic parameters assessed during and after exercise. The higher the insulin resistance the lower the cardiac output during maximal exercise in men with type 1 diabetes.

  16. Beat-by-beat analysis of cardiac output and blood pressure responses to short-term barostimulation in different body positions

    Science.gov (United States)

    Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.

    Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.

  17. The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise

    International Nuclear Information System (INIS)

    Wang, L; Poon, C C Y; Zhang, Y T

    2010-01-01

    Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation method that can be used under these challenging conditions. The tube model was utilized to derive a CO index, namely the pulse time reflection ratio (PTRR) from an electrocardiogram and photoplethysmogram. After calibration, the PTRR can be used to estimate beat-to-beat CO. The proposed method was verified against CO measured by impedance cardiography on 19 healthy subjects in an incremental intensity exercise test. Results showed that there were strong correlations (r) between the PTRR and reference CO in 18 subjects (mean r: 0.88, n = 245 trials). Two calibration approaches reported in the literature were applied to the proposed method and the corresponding bias ± precisions of estimation errors were 0 ± 1.89 L min −1 and −0.22 ± 2.12 L min −1 , respectively. The percent errors were 21.94% and 24.90%, smaller than the clinical acceptance limit (30%). To conclude, after calibration, this method can be used to monitor CO on healthy subjects during incremental intensity exercise

  18. Prophylactic milrinone for the prevention of low cardiac output syndrome and mortality in children undergoing surgery for congenital heart disease.

    Science.gov (United States)

    Burkhardt, Barbara E U; Rücker, Gerta; Stiller, Brigitte

    2015-03-25

    Children with congenital heart disease often undergo heart surgery at a young age. They are at risk for postoperative low cardiac output syndrome (LCOS) or death. Milrinone may be used to provide inotropic and vasodilatory support during the immediate postoperative period. This review examines the effectiveness of prophylactic postoperative use of milrinone to prevent LCOS or death in children having undergone surgery for congenital heart disease. Electronic and manual literature searches were performed to identify randomised controlled trials. We searched CENTRAL, MEDLINE, EMBASE and Web of Science in February 2014 and conducted a top-up search in September 2014 as well as clinical trial registries and reference lists of published studies. We did not apply any language restrictions. Only randomised controlled trials were selected for analysis. We considered studies with newborn infants, infants, toddlers, and children up to 12 years of age. Two review authors independently extracted data according to a pre-defined protocol. We obtained additional information from all study authors. Three of the five included studies compared milrinone versus levosimendan, one study compared milrinone with placebo, and one compared milrinone verus dobutamine, with 101, 242, and 50 participants, respectively. Three trials were at low risk of bias while two were at higher risk of bias. The number and definitions of outcomes were non-uniform as well. In one study comparing two doses of milrinone and placebo, there was some evidence in an overall comparison of milrinone versus placebo that milrinone lowered risk for LCOS (risk ratio (RR) 0.52, 95% confidence interval (CI) 0.28 to 0.96; 227 participants). The results from two small studies do not provide enough information to determine whether milrinone increases the risk of LCOS when compared to levosimendan (RR 1.22, 95% CI 0.32 to 4.65; 59 participants). Mortality rates in the studies were low, and there was insufficient evidence to

  19. Diesel Exhaust Inhalation Increases Cardiac Output, Bradyarrhythmias, and Parasympathetic Tone in Aged Heart Failure-Prone Rats

    Science.gov (United States)

    Acute air pollutant inhalation is linked to adverse cardiac events and death, and hospitalizations for heart failure. Diesel exhaust (DE) is a major air pollutant suspected to exacerbate preexisting cardiac conditions, in part, through autonomic and electrophysiologic disturbance...

  20. Aerobic capacity related to cardiac size in young children

    DEFF Research Database (Denmark)

    Dencker, M; Wollmer, P; Karlsson, M

    2013-01-01

    Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base.......Aerobic capacity, defined as peak oxygen uptake (VO2PEAK), is generally considered to be the best single marker for aerobic fitness. We assessed if VO2PEAK is related to different cardiac dimensions in healthy young children on a population base....

  1. Experiences, considerations and emotions relating to cardiogenetic evaluation in relatives of young sudden cardiac death victims

    NARCIS (Netherlands)

    van der Werf, Christian; Onderwater, Astrid T.; van Langen, Irene M.; Smets, Ellen M. A.

    2014-01-01

    Relatives of young sudden cardiac death (SCD) victims are at increased risk of carrying a potentially fatal inherited cardiac disease. Hence, it is recommended to perform an autopsy on the victim and to refer his or her relatives to a cardiogenetics clinic for a full evaluation to identify those at

  2. [Effects of application of pulse contour cardiac output monitoring technology in early treatment of patients with large area burns].

    Science.gov (United States)

    Wang, D Y; Xie, W G; Xi, M M; Li, Z; Wang, B

    2018-01-20

    Objective: To analyze the changes and relationship of early hemodynamic indexes of patients with large area burns monitored by pulse contour cardiac output (PiCCO) monitoring technology, so as to assess the guiding value of this technology in the treatment of patients with large area burns during shock period. Methods: Eighteen patients with large area burns, confirming to the study criteria, were admitted to our unit from May 2016 to May 2017. Pulse contour cardiac output index (PCCI), systemic vascular resistance index (SVRI), global end-diastolic volume index (GEDVI), and extravascular lung water index (EVLWI) of patients were monitored by PiCCO instrument from admission to post injury day (PID) 7, and they were calibrated and recorded once every four hours. The fluid infusion coefficients of patients at the first and second 24 hours post injury were calculated. The blood lactic acid values of patients from PID 1 to 7 were also recorded. The correlations among PCCI, SVRI, and GEDVI as well as the correlation between SVRI and blood lactic acid of these 18 patients were analyzed. Prognosis of patients were recorded. Data were processed with one-way analysis of variance, single sample t test and Bonferroni correction, Pearson correlation analysis, and Spearman rank correlation analysis. Results: (1) There was statistically significant difference in PCCI value of patients from post injury hour (PIH) 4 to 168 ( F =7.428, P 0.05). (2) There was statistically significant difference in SVRI value of patients from PIH 4 to 168 ( F =7.863, P 0.05). (3) There was no statistically significant difference in the GEDVI values of patients from PIH 4 to 168 ( F =0.704, P >0.05). The GEDVI values of patients at PIH 8, 12, 16, 20, and 24 were significantly lower than normal value ( t =-3.112, -3.554, -2.969, -2.450, -2.476, P 0.05). (4) There was statistically significant difference in EVLWI value of patients from PIH 4 to 168 ( F =1.859, P 0.05). (5) The fluid infusion

  3. Assessment of interchangeability rate between 2 methods of measurements: An example with a cardiac output comparison study.

    Science.gov (United States)

    Lorne, Emmanuel; Diouf, Momar; de Wilde, Robert B P; Fischer, Marc-Olivier

    2018-02-01

    The Bland-Altman (BA) and percentage error (PE) methods have been previously described to assess the agreement between 2 methods of medical or laboratory measurements. This type of approach raises several problems: the BA methodology constitutes a subjective approach to interchangeability, whereas the PE approach does not take into account the distribution of values over a range. We describe a new methodology that defines an interchangeability rate between 2 methods of measurement and cutoff values that determine the range of interchangeable values. We used a simulated data and a previously published data set to demonstrate the concept of the method. The interchangeability rate of 5 different cardiac output (CO) pulse contour techniques (Wesseling method, LiDCO, PiCCO, Hemac method, and Modelflow) was calculated, in comparison with the reference pulmonary artery thermodilution CO using our new method. In our example, Modelflow with a good interchangeability rate of 93% and a cutoff value of 4.8 L min, was found to be interchangeable with the thermodilution method for >95% of measurements. Modelflow had a higher interchangeability rate compared to Hemac (93% vs 86%; P = .022) or other monitors (Wesseling cZ = 76%, LiDCO = 73%, and PiCCO = 62%; P < .0001). Simulated data and reanalysis of a data set comparing 5 CO monitors against thermodilution CO showed that, depending on the repeatability of the reference method, the interchangeability rate combined with a cutoff value could be used to define the range of values over which interchangeability remains acceptable.

  4. Electrical Cardiometry to Monitor Cardiac Output in Preterm Infants with Patent Ductus Arteriosus: A Comparison with Echocardiography.

    Science.gov (United States)

    Hsu, Kai-Hsiang; Wu, Tai-Wei; Wu, I-Hsyuan; Lai, Mei-Yin; Hsu, Shih-Yun; Huang, Hsiao-Wen; Mok, Tze-Yee; Lien, Reyin

    2017-01-01

    Electrical cardiometry (EC) is an impedance-based monitoring that provides noninvasive cardiac output (CO) assessment. Through comparison to transthoracic echocardiography (Echo), the accuracy of EC has been verified. However, left-to-right patent ductus arteriosus (PDA) shunting is a concern because PDA shunts aortic flow to the pulmonary artery and may interfere with EC in measuring CO. To determine the agreement between EC and Echo in preterm infants with a hemodynamically significant PDA (hsPDA). We reviewed our hemodynamic database in which simultaneous CO measurements by Echo and EC (Aesculon®) were recorded. Preterm infants with left-to-right shunting hsPDA were enrolled. A total of 105 paired measurements in 36 preterm infants were compared. Infants' median (range) age and weight at measurement were 27+2 weeks (24+0-33+1) and 1,015 g (518-1,880), with mean (95% CI) ductal diameter 2.11 mm (1.99-2.22) or 2.15 mm/kg (2.00-2.30). Mean COEC and COEcho were 252 ± 32 and 258 ± 45 mL/kg/min, respectively, which demonstrated a moderate correlation and without a significant between-measurement difference. Bland-Altman analysis showed a bias, limits of agreement, and error percentage of -5.3 mL/kg/min, -78.3 to 67.7 mL/kg/min, and 28.6%, respectively. There was a trend of increased bias and error percentage of infants with high CO ≥280 mL/kg/min and supported with high-frequency ventilator. EC and Echo have a wide but clinically acceptable agreement in measuring CO in preterm infants with hsPDA. However, for infants with high CO or ventilated by high-frequency ventilation, interpretation of COEC should be approached with caution. © 2017 S. Karger AG, Basel.

  5. Does obesity affect the non-invasive measurement of cardiac output performed by electrical cardiometry in children and adolescents?

    Science.gov (United States)

    Altamirano-Diaz, Luis; Welisch, Eva; Rauch, Ralf; Miller, Michael; Park, Teresa Sohee; Norozi, Kambiz

    2018-02-01

    Electrical cardiometry (EC) is a non-invasive and inexpensive method for hemodynamic assessment and monitoring. However, its feasibility for widespread clinical use, especially for the obese population, has yet to be determined. In this study, we evaluated the agreement and reliability of EC compared to transthoracic Doppler echocardiography (TTE) in normal, overweight, and obese children and adolescents. We measured stroke volume (SV) and cardiac output (CO) of 131 participants using EC and TTE simultaneously. We further divided these participants according to BMI percentiles for subanalyses: 95% obese (n = 83). Due to small sample size of the overweight group, we combined overweight and obese groups (OW+OB) with no significant change in results (SV and CO) before and after combining groups. There were strong correlations between EC and TTE measurements of SV (r = 0.869 and r = 0.846; p < 0.0001) and CO (r = 0.831 and r = 0.815; p < 0.0001) in normal and OW+OB groups, respectively. Bias and percentage error for CO measurements were 0.240 and 29.7%, and 0.042 and 29.5% in the normal and OW+OB groups, respectively. Indexed values for SV were lower in the OW+OB group than in the normal weight group when measured by EC (p < 0.0001) but no differences were seen when measured by TTE (p = 0.096). In all weight groups, there were strong correlations and good agreement between EC and TTE. However, EC may underestimate hemodynamic measurements in obese participants due to fat tissue.

  6. Decreased 2,3-diphosphoglycerate concentration in low cardiac output patients and its influence on the determination of in vivo p50.

    Science.gov (United States)

    Piccioni, Marilde A; Cestari, Idágene A; Strunz, Célia M C; Auler, José O

    2003-08-01

    We investigated whether 2,3-diphosphoglycerate (2,3-DPG) is altered in patients with low cardiac output and the influence of its concentration on the calculation of in vivo P(50). Biochemical and blood gas analysis were performed along with the measurement of cardiac output and body temperature in 13 patients submitted to cardiopulmonary bypass surgeries without the use of donor blood. In vivo P(50) was calculated using the measured (P(50m)) and the estimated 2,3-DPG (P(50e)). 2,3-DPG concentration was lower in these patients when compared to the values obtained in normal volunteers (6.9 +/- 2.2 vs. 11.9 +/- 2.4 microm/gHb). P(50m) was lower than P(50e) (21.6 +/- 1.1 vs. 30.1 +/- 1.2 mm Hg) at all time points. Our data show that in patients with low cardiac output, 2,3-DPG concentration is reduced. Therefore, in these patients, the use of standard values for this variable may introduce an error in the calculation of in vivo P(50).

  7. Cardiovascular Ultrasound of Neonatal Long Evans Rats Exposed Prenatally to Trichloroacetic Acid: Effects on Heart Rate, Ejection Fraction, and Cardiac Output

    Science.gov (United States)

    This abstract describes the use of a relatively new technology, cardiovascular ultrasound (echocardiography) for evaluating developmental toxicity affecting heart development. The abstract describes the effects of two known cardiac teratogens, trichloroacetic acid and dimethadio...

  8. Change in end-tidal carbon dioxide outperforms other surrogates for change in cardiac output during fluid challenge.

    Science.gov (United States)

    Lakhal, K; Nay, M A; Kamel, T; Lortat-Jacob, B; Ehrmann, S; Rozec, B; Boulain, T

    2017-03-01

    During fluid challenge, volume expansion (VE)-induced increase in cardiac output (Δ VE CO) is seldom measured. In patients with shock undergoing strictly controlled mechanical ventilation and receiving VE, we assessed minimally invasive surrogates for Δ VE CO (by transthoracic echocardiography): fluid-induced increases in end-tidal carbon dioxide (Δ VE E'CO2 ); pulse (Δ VE PP), systolic (Δ VE SBP), and mean systemic blood pressure (Δ VE MBP); and femoral artery Doppler flow (Δ VE FemFlow). In the absence of arrhythmia, fluid-induced decrease in heart rate (Δ VE HR) and in pulse pressure respiratory variation (Δ VE PPV) were also evaluated. Areas under the receiver operating characteristic curves (AUC ROC s) reflect the ability to identify a response to VE (Δ VE CO ≥15%). In 86 patients, Δ VE E'CO2 had an AUC ROC =0.82 [interquartile range 0.73-0.90], significantly higher than the AUC ROC for Δ VE PP, Δ VE SBP, Δ VE MBP, and Δ VE FemFlow (AUC ROC =0.61-0.65, all P  1 mm Hg (>0.13 kPa) had good positive (5.0 [2.6-9.8]) and fair negative (0.29 [0.2-0.5]) likelihood ratios. The 16 patients with arrhythmia had similar relationships between Δ VE E'CO2 and Δ VE CO to patients with regular rhythm ( r 2 =0.23 in both subgroups). In 60 patients with no arrhythmia, Δ VE E'CO2 (AUC ROC =0.84 [0.72-0.92]) outperformed Δ VE HR (AUC ROC =0.52 [0.39-0.66], P AUC ROC =0.73 [0.60-0.84], P =0.21). In the 45 patients with no arrhythmia and receiving ventilation with tidal volume AUC ROC =0.86 [0.72-0.95] vs 0.66 [0.49-0.80], P =0.02. Δ VE E'CO2 outperformed Δ VE PP, Δ VE SBP, Δ VE MBP, Δ VE FemFlow, and Δ VE HR and, during protective ventilation, arrhythmia, or both, it also outperformed Δ VE PPV. A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) indicated a likely response to VE. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  9. Uncomplicated human type 2 diabetes is associated with meal-induced blood pressure lowering and cardiac output increase.

    Science.gov (United States)

    Smits, Mark M; Muskiet, Marcel H A; Tushuizen, Maarten E; Kwa, Kelly A A; Karemaker, John M; van Raalte, Daniël H; Diamant, Michaela

    2014-12-01

    Since many type 2 diabetes patients experience postprandial hypotension, the aim of this study was to unravel meal-related changes in systemic hemodynamics and autonomic nervous system (ANS)-balance. Forty-two age-matched males (15 type 2 diabetes; 12 metabolic syndrome; 15 controls) without overt autonomic neuropathy received a standardized high-fat mixed meal after an overnight fast. Hemodynamic variables were measured by finger plethysmography. Fourier analysis was used to calculate the low-/high-frequency (LF/HF)-ratio, a marker of autonomic nervous system-balance, and baroreceptor reflex sensitivity (BRS). Following the meal, diastolic blood pressure (DBP) decreased in type 2 diabetes patients only, paralleled by a significant decrement in systemic vascular resistance (SVR) and an increase in cardiac index. All groups showed an increase in postprandial heart rate. Controls, but not metabolic syndrome or type 2 diabetes patients, showed a meal-related increase in LF/HF-ratio. When combining all study subjects, homeostatic model assessment-insulin resistance (HOMA-IR) was inversely correlated with changes in DBP, SVR, LF/HF-ratio and BRS. Based on these data, we hypothesize that in patients with uncomplicated type 2 diabetes, insulin resistance hampers adequate meal-induced sympathetic activation, leading to a decrease in SVR and resulting in a postprandial drop in DBP. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Impact of cardiac rehabilitation on health related quality of life.

    LENUS (Irish Health Repository)

    Riaz, A

    2012-02-01

    Cardiac rehabilitation (CR) programs are recognized as integral part of the comprehensive care of patients with cardiovascular disease and are recommended as useful and effective (Class I) by the American Heart Association (AHA). In this study we used serial administration of the short form 36 (SF36) to evaluate patient\\'s response to CR in terms of improvement in Health related Quality of Life. A total of 49 patients were included in the analysis. There was a significant improvement observed after CR in the Physical Capacity Score (42.3 vs 49.9 p = 0.0005). There was no significant improvement in the Mental Capacity Score (54.8 vs 54.9 p = 0.96). We conclude that Cardiac Rehabilitation Program causes a significant improvement in the health related quality of life of patients by improving their physical health and well being but does not improve the mental capacity which is already at a healthy level before CR.

  11. Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors

    International Nuclear Information System (INIS)

    Tsai, J.-S.; Rivard, Mark J.; Engler, Mark J.; Mignano, John E.; Wazer, David E.; Shucart, William A.

    2003-01-01

    Though the 4 mm Gamma Knife helmet is used routinely, there is disagreement in the Gamma Knife users community on the value of the 4 mm helmet relative output factor. A range of relative output factors is used, and this variation may impair observations of dose response and optimization of prescribed dose. To study this variation, measurements were performed using the following radiation detectors: silicon diode, diamond detector, radiographic film, radiochromic film, and TLD cubes. To facilitate positioning of the silicon diode and diamond detector, a three-dimensional translation micrometer was used to iteratively determine the position of maximum detector response. Positioning of the films and TLDs was accomplished by manufacturing custom holders for each technique. Results from all five measurement techniques indicate that the 4 mm helmet relative output factor is 0.868±0.014. Within the experimental uncertainties, this value is in good agreement with results obtained by other investigators using diverse techniques

  12. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure.

    Science.gov (United States)

    Hlebowicz, Joanna; Lindstedt, Sandra; Björgell, Ola; Dencker, Magnus

    2011-12-29

    Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR), blood pressure and cardiac output (CO), although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1), ghrelin on CO, HR, stroke volume (SV), and blood pressure. Eleven healthy men and twelve healthy women ((mean ± SEM) aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m(2))) were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P blood pressure (P = 0.021, r = -0.681), and the change in SV (P = 0.008, r = -0.748) relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814) in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966) in men. No statistically significant correlations were seen in women. Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the primary intervention. NCT01027507.

  13. Indexation of cardiac output to biometric parameters in critically ill patients: A systematic analysis of a transpulmonary thermodilution-derived database.

    Science.gov (United States)

    Saugel, Bernd; Mair, Sebastian; Götz, Simon Q; Tschirdewahn, Julia; Frank, Johanna; Höllthaler, Josef; Schmid, Roland M; Huber, Wolfgang

    2015-10-01

    Cardiac output (CO) (liters per minute) is usually normalized (ie, indexed) to the patient's body surface area (BSA) resulting in the hemodynamic variable cardiac index (CI) (liters per minute per square meter). We aimed (1) to evaluate the impact of different body weight-based CO indexations on the resulting CI values and (2) to identify biometric parameters independently associated with CO in critically ill patients. The study is an analysis of a database containing transpulmonary thermodilution-derived hemodynamic variables of 234 medical intensive care unit patients. Cardiac index indexed to actual BSA was statistically significantly lower compared with CI indexed to predicted BSA in the totality of patients and in the subgroups of patients with body mass index greater than or equal to 25 kg/m(2) but less than 30 kg/m(2) and body mass index greater than or equal to 30 kg/m(2) (with a statistically significant difference in the proportion of low and high CI measurements). Multivariate analysis of the first CO measurement of each patient demonstrated that CO was independently associated with age (P biometric factors independently associated with CO. Age was identified as the most important factor with each year of age decreasing CO by 66 mL/min (95% confidence interval, 47-86 mL/min). The indexation of CO to BSA is highly dependent on the body weight estimation formula used to calculate BSA. Cardiac output is independently associated with the biometric factors age, height, and BWact. These factors might be considered for indexation of CO. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Low cardiac output as physiological phenomenon in hibernating, free-ranging Scandinavian brown bears (Ursus arctos) - an observational study

    DEFF Research Database (Denmark)

    Jørgensen, Peter Godsk; Arnemo, Jon; Swenson, Jon E

    2014-01-01

    cardiac function associated with metabolic depression in the hibernating vs. active states in free-ranging Scandinavian brown bears. METHODS: We performed echocardiography on seven free-ranging brown bears in Dalarna, Sweden, anesthetized with medetomidine-zolazepam-tiletamine-ketamine during winter.......31) l/min vs. 3.54 (SD: 1.04) l/min (P=0.003), and mean cardiac index 0.63 (SD: 0.21) l/min/kg vs. 2.45 (SD: 0.52) l/min/ m2 (Pdisease...

  15. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass

    Science.gov (United States)

    Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillon, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-01-01

    Importance Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. Objective To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Design, Setting, and Participants Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Interventions Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Main Outcomes and Measures Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Results Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, −7% [95% CI, −17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse

  16. Effect of Levosimendan on Low Cardiac Output Syndrome in Patients With Low Ejection Fraction Undergoing Coronary Artery Bypass Grafting With Cardiopulmonary Bypass: The LICORN Randomized Clinical Trial.

    Science.gov (United States)

    Cholley, Bernard; Caruba, Thibaut; Grosjean, Sandrine; Amour, Julien; Ouattara, Alexandre; Villacorta, Judith; Miguet, Bertrand; Guinet, Patrick; Lévy, François; Squara, Pierre; Aït Hamou, Nora; Carillion, Aude; Boyer, Julie; Boughenou, Marie-Fazia; Rosier, Sebastien; Robin, Emmanuel; Radutoiu, Mihail; Durand, Michel; Guidon, Catherine; Desebbe, Olivier; Charles-Nelson, Anaïs; Menasché, Philippe; Rozec, Bertrand; Girard, Claude; Fellahi, Jean-Luc; Pirracchio, Romain; Chatellier, Gilles

    2017-08-08

    Low cardiac output syndrome after cardiac surgery is associated with high morbidity and mortality in patients with impaired left ventricular function. To assess the ability of preoperative levosimendan to prevent postoperative low cardiac output syndrome. Randomized, double-blind, placebo-controlled trial conducted in 13 French cardiac surgical centers. Patients with a left ventricular ejection fraction less than or equal to 40% and scheduled for isolated or combined coronary artery bypass grafting with cardiopulmonary bypass were enrolled from June 2013 until May 2015 and followed during 6 months (last follow-up, November 30, 2015). Patients were assigned to a 24-hour infusion of levosimendan 0.1 µg/kg/min (n = 167) or placebo (n = 168) initiated after anesthetic induction. Composite end point reflecting low cardiac output syndrome with need for a catecholamine infusion 48 hours after study drug initiation, need for a left ventricular mechanical assist device or failure to wean from it at 96 hours after study drug initiation when the device was inserted preoperatively, or need for renal replacement therapy at any time postoperatively. It was hypothesized that levosimendan would reduce the incidence of this composite end point by 15% in comparison with placebo. Among 336 randomized patients (mean age, 68 years; 16% women), 333 completed the trial. The primary end point occurred in 87 patients (52%) in the levosimendan group and 101 patients (61%) in the placebo group (absolute risk difference taking into account center effect, -7% [95% CI, -17% to 3%]; P = .15). Predefined subgroup analyses found no interaction with ejection fraction less than 30%, type of surgery, and preoperative use of β-blockers, intra-aortic balloon pump, or catecholamines. The prevalence of hypotension (57% vs 48%), atrial fibrillation (50% vs 40%), and other adverse events did not significantly differ between levosimendan and placebo. Among patients with low ejection fraction

  17. Area/latency optimized early output asynchronous full adders and relative-timed ripple carry adders.

    Science.gov (United States)

    Balasubramanian, P; Yamashita, S

    2016-01-01

    This article presents two area/latency optimized gate level asynchronous full adder designs which correspond to early output logic. The proposed full adders are constructed using the delay-insensitive dual-rail code and adhere to the four-phase return-to-zero handshaking. For an asynchronous ripple carry adder (RCA) constructed using the proposed early output full adders, the relative-timing assumption becomes necessary and the inherent advantages of the relative-timed RCA are: (1) computation with valid inputs, i.e., forward latency is data-dependent, and (2) computation with spacer inputs involves a bare minimum constant reverse latency of just one full adder delay, thus resulting in the optimal cycle time. With respect to different 32-bit RCA implementations, and in comparison with the optimized strong-indication, weak-indication, and early output full adder designs, one of the proposed early output full adders achieves respective reductions in latency by 67.8, 12.3 and 6.1 %, while the other proposed early output full adder achieves corresponding reductions in area by 32.6, 24.6 and 6.9 %, with practically no power penalty. Further, the proposed early output full adders based asynchronous RCAs enable minimum reductions in cycle time by 83.4, 15, and 8.8 % when considering carry-propagation over the entire RCA width of 32-bits, and maximum reductions in cycle time by 97.5, 27.4, and 22.4 % for the consideration of a typical carry chain length of 4 full adder stages, when compared to the least of the cycle time estimates of various strong-indication, weak-indication, and early output asynchronous RCAs of similar size. All the asynchronous full adders and RCAs were realized using standard cells in a semi-custom design fashion based on a 32/28 nm CMOS process technology.

  18. The effect of relative humidity on output performance of inclined and ...

    African Journals Online (AJOL)

    The set-up of 70 Watts solar panel was inclined stationary at 150 for maximum solar reception while the set-up of 80 Watts solar panel had automatic solar tracker for effective capturing of solar radiation. For 70 Watts solar panel, the maximum power output of 59.99 Watt was obtained when the relative humidity was 30%.

  19. Quantum-optical input-output relations for dispersive and lossy multilayer dielectric plates

    International Nuclear Information System (INIS)

    Gruner, T.; Welsch, D.

    1996-01-01

    Using the Green-function approach to the problem of quantization of the phenomenological Maxwell theory, the propagation of quantized radiation through dispersive and absorptive multilayer dielectric plates is studied. Input-output relations are derived, with special emphasis on the determination of the quantum noise generators associated with the absorption of radiation inside the dielectric matter. The input-output relations are used to express arbitrary correlation functions of the outgoing field in terms of correlation functions of the incoming field and those of the noise generators. To illustrate the theory, photons at dielectric tunneling barriers are considered. It is shown that inclusion in the calculations of losses in the photonic band gaps may substantially change the barrier traversal times. copyright 1996 The American Physical Society

  20. The effect of endogenously released glucose, insulin, glucagon-like peptide 1, ghrelin on cardiac output, heart rate, stroke volume, and blood pressure

    Directory of Open Access Journals (Sweden)

    Hlebowicz Joanna

    2011-12-01

    Full Text Available Abstract Background Ingestion of a meal increases the blood flow to the gastrointestinal organs and affects the heart rate (HR, blood pressure and cardiac output (CO, although the mechanisms are not known. The aim of this study was to evaluate the effect of endogenously released glucose, insulin, glucagon-like peptide 1 (GLP-1, ghrelin on CO, HR, stroke volume (SV, and blood pressure. Methods Eleven healthy men and twelve healthy women ((mean ± SEM aged: 26 ± 0.2 y; body mass index: 21.8 ± 0.1 kg/m2 were included in this study. The CO, HR, SV, systolic and diastolic blood pressure, antral area, gastric emptying rate, and glucose, insulin, GLP-1 and ghrelin levels were measured. Results The CO and SV at 30 min were significantly higher, and the diastolic blood pressure was significantly lower, than the fasting in both men and women (P P = 0.015, r = 0.946, and between ghrelin levels and HR (P = 0.013, r = 0.951 at 110 min. Significant correlations were also found between the change in glucose level at 30 min and the change in systolic blood pressure (P = 0.021, r = -0.681, and the change in SV (P = 0.008, r = -0.748 relative to the fasting in men. The insulin 0-30 min AUC was significantly correlated to the CO 0-30 min AUC (P = 0.002, r = 0.814 in men. Significant correlations were also found between the 0-120 min ghrelin and HR AUCs (P = 0.007, r = 0.966 in men. No statistically significant correlations were seen in women. Conclusions Physiological changes in the levels of glucose, insulin, GLP-1 and ghrelin may influence the activity of the heart and the blood pressure. There may also be gender-related differences in the haemodynamic responses to postprandial changes in hormone levels. The results of this study show that subjects should not eat immediately prior to, or during, the evaluation of cardiovascular interventions as postprandial affects may affect the results, leading to erroneous interpretation of the cardiovascular effects of the

  1. Sex-related differences in the normal cardiac response to upright exercise

    International Nuclear Information System (INIS)

    Higginbotham, M.B.; Morris, K.G.; Coleman, R.E.; Cobb, F.R.

    1984-01-01

    In previous studies from this laboratory, it was found that approximately 30% of women with chest pain and normal coronary arteries demonstrated either a decrease in or a failure to increase radionuclide ejection fraction during exercise. To examine the hypothesis that this apparent abnormality in left ventricular function represents a physiologic difference between men and women, a prospective study was made of central and peripheral cardiovascular responses to exercise in 31 age-matched healthy volunteers (16 women and 15 men). A combination of quantitative radionuclide (technetium) angiography and expired-gas analysis was used to measure ejection fraction and relative changes in end-diastolic counts, stroke counts, count output, and arteriovenous oxygen difference during symptom-limited upright bicycle exercise. Normal male and female volunteers demonstrated comparable baseline left ventricular function and similar aerobic capacity, as determined by weight-adjusted peak oxygen consumption. However, their cardiac responses to exercise were significantly different. The ejection fraction increased by 5 points or more in 14 of 15 men, but in only seven of the 16 women. End-diastolic counts increased by 30% in women, but was unchanged in men. Because decreases in ejection fraction were matched by increases in end-diastolic counts, relative increases in stroke counts and count output were the same for men and women. These data demonstrate a basic difference between men and women with respect to the mechanism by which they achieve a normal response of stroke volume to exercise; these differences must be taken into account when measurements of cardiac function during exercise stress are used for diagnostic purposes

  2. The calculation of relative output factor and depth dose for irregular electron fields in water

    International Nuclear Information System (INIS)

    Dunscombe, Peter; McGhee, Peter; Chu, Terence

    1996-01-01

    Purpose: A technique, based on sector integration and interpolation, has been developed for the computation of both relative output factor and depth dose of irregular electron fields in water. The purpose of this study was to determine the minimum experimental data set required for the technique to yield results within accepted dosimetric tolerances. Materials and Methods: PC based software has been written to perform the calculations necessary to dosimetrically characterize irregular shaped electron fields. The field outline is entered via digitiser and the SSD and energy via the keyboard. The irregular field is segmented into sectors of specified angle (2 deg. was used for this study) and the radius of each sector computed. The central ray depth dose is reconstructed by summing the contributions from each sector deduced from calibration depth doses measured for circular fields. Relative output factors and depth doses at SSDs at which calibrations were not performed are found by interpolation. Calibration data were measured for circular fields from 2 to 9 cm diameter at 100, 105, 110, and 115 cm SSD. A clinical cut out can be characterized in less than 2 minutes including entry of the outline using this software. The performance of the technique was evaluated by comparing calculated relative output factors, surface dose and the locations of d 80 , d 50 and d 20 with experimental measurements on a variety of cut out shapes at 9 and 18 MeV. The calibration data set (derived from circular cut outs) was systematically reduced to identify the minimum required to yield an accuracy consistent with current recommendations. Results: The figure illustrates the ability of the technique to calculate the depth dose for an irregular field (shown in the insert). It was found that to achieve an accuracy of 2% in relative output factor and 2% or 2 mm (our criterion) in percentage depth dose, calibration data from five circular fields at the four SSDs spanning the range 100-115 cm

  3. Prophylactic levosimendan for the prevention of low cardiac output syndrome and mortality in paediatric patients undergoing surgery for congenital heart disease.

    Science.gov (United States)

    Hummel, Johanna; Rücker, Gerta; Stiller, Brigitte

    2017-08-02

    Low cardiac output syndrome remains a serious complication, and accounts for substantial morbidity and mortality in the postoperative course of paediatric patients undergoing surgery for congenital heart disease. Standard prophylactic and therapeutic strategies for low cardiac output syndrome are based mainly on catecholamines, which are effective drugs, but have considerable side effects. Levosimendan, a calcium sensitiser, enhances the myocardial function by generating more energy-efficient myocardial contractility than achieved via adrenergic stimulation with catecholamines. Thus potentially, levosimendan is a beneficial alternative to standard medication for the prevention of low cardiac output syndrome in paediatric patients after open heart surgery. To review the efficacy and safety of the postoperative prophylactic use of levosimendan for the prevention of low cardiac output syndrome and mortality in paediatric patients undergoing surgery for congenital heart disease. We identified trials via systematic searches of CENTRAL, MEDLINE, Embase, and Web of Science, as well as clinical trial registries, in June 2016. Reference lists from primary studies and review articles were checked for additional references. We only included randomised controlled trials (RCT) in our analysis that compared prophylactic levosimendan with standard medication or placebo, in infants and children up to 18 years of age, who were undergoing surgery for congenital heart disease. Two review authors independently extracted data and assessed risk of bias according to a pre-defined protocol. We obtained additional information from all but one of the study authors of the included studies. We used the five GRADE considerations (study limitations, consistency of effect, imprecision, indirectness, and publication bias) to assess the quality of evidence from the studies that contributed data to the meta-analyses for the prespecified outcomes. We created a 'Summary of findings' table to

  4. Contributions of pulmonary hypertension to HIV-related cardiac dysfunction

    Directory of Open Access Journals (Sweden)

    Godsent C. Isiguzo

    2013-09-01

    Conclusion: Immune-suppression affects the cardiac function adversely and coexisting pulmonary hypertension contributes to poor systolic and diastolic function in affected patients. The subtle nature of presentation of pulmonary hypertension and other cardiac dysfunctions in HIV/AIDS patients demand a high-index of suspicion and early intervention if detected, to ensure better care for these emerging threats to our patients.

  5. Early diagnosis of myocardial infarction using absolute and relative changes in cardiac troponin concentrations

    OpenAIRE

    Irfan Affan Bin; Reichlin Tobias R.; Twerenbold Raphael; Meister Marc; Moehring Berit; Wildi Karin; Bassetti Stefano; Zellweger Christa; Gimenez Maria Rubini; Hoeller Rebeca; Murray Karsten; Sou SeoungMann; Mueller Mira; Mosimann Tamina; Reiter Miriam

    2013-01-01

    Background: Absolute changes in high sensitivity cardiac troponin T (hs cTnT) seem to have higher diagnostic accuracy in the early diagnosis of acute myocardial infarction compared with relative changes. It is unknown whether the same applies to high sensitivity cardiac troponin I (hs cTnI) assays and whether the combination of absolute and relative change might further increase accuracy. Methods: In a prospective international multicenter study high sensitivity cardiac troponin (hs cTn) was ...

  6. Input-output relation and energy efficiency in the neuron with different spike threshold dynamics.

    Science.gov (United States)

    Yi, Guo-Sheng; Wang, Jiang; Tsang, Kai-Ming; Wei, Xi-Le; Deng, Bin

    2015-01-01

    Neuron encodes and transmits information through generating sequences of output spikes, which is a high energy-consuming process. The spike is initiated when membrane depolarization reaches a threshold voltage. In many neurons, threshold is dynamic and depends on the rate of membrane depolarization (dV/dt) preceding a spike. Identifying the metabolic energy involved in neural coding and their relationship to threshold dynamic is critical to understanding neuronal function and evolution. Here, we use a modified Morris-Lecar model to investigate neuronal input-output property and energy efficiency associated with different spike threshold dynamics. We find that the neurons with dynamic threshold sensitive to dV/dt generate discontinuous frequency-current curve and type II phase response curve (PRC) through Hopf bifurcation, and weak noise could prohibit spiking when bifurcation just occurs. The threshold that is insensitive to dV/dt, instead, results in a continuous frequency-current curve, a type I PRC and a saddle-node on invariant circle bifurcation, and simultaneously weak noise cannot inhibit spiking. It is also shown that the bifurcation, frequency-current curve and PRC type associated with different threshold dynamics arise from the distinct subthreshold interactions of membrane currents. Further, we observe that the energy consumption of the neuron is related to its firing characteristics. The depolarization of spike threshold improves neuronal energy efficiency by reducing the overlap of Na(+) and K(+) currents during an action potential. The high energy efficiency is achieved at more depolarized spike threshold and high stimulus current. These results provide a fundamental biophysical connection that links spike threshold dynamics, input-output relation, energetics and spike initiation, which could contribute to uncover neural encoding mechanism.

  7. Serum cardiac troponin I in acute stroke is related to serum cortisol and TNF-alpha

    DEFF Research Database (Denmark)

    Christensen, Hanne Krarup; Johannesen, Helle Hjorth; Christensen, Anders Fogh

    2004-01-01

    Serum cardiac troponin I (cTnI) is a specific marker of myocardial injury related to in-patient fatality and cardiac injury in acute stroke. We investigated whether cTnI in acute stroke is related to serum cortisol, acute inflammatory response, and insular damage. We also investigated whether c...

  8. Treatment Related Cardiac Toxicity in Patients Treated for Breast Cancer

    National Research Council Canada - National Science Library

    Marks, Lawrence B

    2006-01-01

    Purpose: To determine the incidence dose/time-dependence and functional significance of regional cardiac perfusion abnormalities in patients with left-sided breast cancer treated with radiation therapy (RT...

  9. Exciton correlations and input–output relations in non-equilibrium exciton superfluids

    International Nuclear Information System (INIS)

    Ye, Jinwu; Sun, Fadi; Yu, Yi-Xiang; Liu, Wuming

    2013-01-01

    The photoluminescence (PL) measurements on photons and the transport measurements on excitons are the two types of independent and complementary detection tools to search for possible exciton superfluids in electron–hole semi-conductor bilayer systems. In fact, it was believed that the transport measurements can provide more direct evidences on superfluids than the spectroscopic measurements. It is important to establish the relations between the two kinds of measurements. In this paper, using quantum Heisenberg–Langevin equations, we establish such a connection by calculating various exciton correlation functions in the putative exciton superfluids. These correlation functions include both normal and anomalous greater, lesser, advanced, retarded, and time-ordered exciton Green functions and also various two exciton correlation functions. We also evaluate the corresponding normal and anomalous spectral weights and the Keldysh distribution functions. We stress the violations of the fluctuation and dissipation theorem among these various exciton correlation functions in the non-equilibrium exciton superfluids. We also explore the input–output relations between various exciton correlation functions and those of emitted photons such as the angle resolved photon power spectrum, phase sensitive two mode squeezing spectrum and two photon correlations. Applications to possible superfluids in the exciton–polariton systems are also mentioned. For a comparison, using conventional imaginary time formalism, we also calculate all the exciton correlation functions in an equilibrium dissipative exciton superfluid in the electron–electron coupled semi-conductor bilayers at the quantum Hall regime at the total filling factor ν T =1. We stress the analogies and also important differences between the correlations functions in the two exciton superfluid systems. - Highlights: ► Establish the relations between photoluminescence and transport measurements. ► Stress the

  10. The relation between input-output transformation and gastrointestinal nematode infections on dairy farms.

    Science.gov (United States)

    van der Voort, M; Van Meensel, J; Lauwers, L; Van Huylenbroeck, G; Charlier, J

    2016-02-01

    Efficiency analysis is used for assessing links between technical efficiency (TE) of livestock farms and animal diseases. However, previous studies often do not make the link with the allocation of inputs and mainly present average effects that ignore the often huge differences among farms. In this paper, we studied the relationship between exposure to gastrointestinal (GI) nematode infections, the TE and the input allocation on dairy farms. Although the traditional cost allocative efficiency (CAE) indicator adequately measures how a given input allocation differs from the cost-minimising input allocation, they do not represent the unique input allocation of farms. Similar CAE scores may be obtained for farms with different input allocations. Therefore, we propose an adjusted allocative efficiency index (AAEI) to measure the unique input allocation of farms. Combining this AAEI with the TE score allows determining the unique input-output position of each farm. The method is illustrated by estimating efficiency scores using data envelopment analysis (DEA) on a sample of 152 dairy farms in Flanders for which both accountancy and parasitic monitoring data were available. Three groups of farms with a different input-output position can be distinguished based on cluster analysis: (1) technically inefficient farms, with a relatively low use of concentrates per 100 l milk and a high exposure to infection, (2) farms with an intermediate TE, relatively high use of concentrates per 100 l milk and a low exposure to infection, (3) farms with the highest TE, relatively low roughage use per 100 l milk and a relatively high exposure to infection. Correlation analysis indicates for each group how the level of exposure to GI nematodes is associated or not with improved economic performance. The results suggest that improving both the economic performance and exposure to infection seems only of interest for highly TE farms. The findings indicate that current farm recommendations

  11. Relative contribution of glycogenolysis and gluconeogenesis to basal, glucagon- and nerve stimulation-dependent glucose output in the perfused liver from fed and fasted rats

    NARCIS (Netherlands)

    Beuers, U.; JUNGERMANN, K.

    1990-01-01

    The relative contribution to basal, glucagon- and nerve stimulation-enhanced glucose output of glycogenolysis (glucose output in the presence of the gluconeogenic inhibitor mercaptopicolinate) and gluconeogenesis (difference in glucose output in the absence and presence of the inhibitor) was

  12. Characterization of exercise limitations by evaluating individual cardiac output patterns : A prospective cohort study in patients with chronic heart failure

    NARCIS (Netherlands)

    Spee, R.F.; Niemeijer, V.M.; Wessels, B.; Jansen, J.P.; Wijn, P.F.F.; Doevendans, P.A.F.M.; Kemps, H.M.C.

    2015-01-01

    Background: Patients with chronic heart failure (CHF) suffer from exercise intolerance due to impaired central hemodynamics and subsequent alterations in peripheral skeletal muscle function and structure. The relative contribution of central versus peripheral factors in the reduced exercise capacity

  13. Characterization of exercise limitations by evaluating individual cardiac output patterns: a prospective cohort study in patients with chronic heart failure

    NARCIS (Netherlands)

    Spee, Ruud F.; Niemeijer, Victor M.; Wessels, Bart; Jansen, Jasper P.; Wijn, Pieter F. F.; Doevendans, Pieter A. F. M.; Kemps, Hareld M. C.

    2015-01-01

    Patients with chronic heart failure (CHF) suffer from exercise intolerance due to impaired central hemodynamics and subsequent alterations in peripheral skeletal muscle function and structure. The relative contribution of central versus peripheral factors in the reduced exercise capacity is still

  14. Do diagnosis-related group-based payments incentivise hospitals to adjust output mix?

    Science.gov (United States)

    Liang, Li-Lin

    2015-04-01

    This study investigates whether the diagnosis-related group (DRG)-based payment method motivates hospitals to adjust output mix in order to maximise profits. The hypothesis is that when there is an increase in profitability of a DRG, hospitals will increase the proportion of that DRG (own-price effects) and decrease those of other DRGs (cross-price effects), except in cases where there are scope economies in producing two different DRGs. This conjecture is tested in the context of the case payment scheme (CPS) under Taiwan's National Health Insurance programme over the period of July 1999 to December 2004. To tackle endogeneity of DRG profitability and treatment policy, a fixed-effects three-stage least squares method is applied. The results support the hypothesised own-price and cross-price effects, showing that DRGs which share similar resources appear to be complements rather substitutes. For-profit hospitals do not appear to be more responsive to DRG profitability, possibly because of their institutional characteristics and bonds with local communities. The key conclusion is that DRG-based payments will encourage a type of 'product-range' specialisation, which may improve hospital efficiency in the long run. However, further research is needed on how changes in output mix impact patient access and pay-outs of health insurance. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Uncomplicated human type 2 diabetes is associated with meal-induced blood pressure lowering and cardiac output increase

    NARCIS (Netherlands)

    Smits, Mark M.; Muskiet, Marcel H. A.; Tushuizen, Maarten E.; Kwa, Kelly A. A.; Karemaker, John M.; van Raalte, Daniël H.; Diamant, Michaela

    2014-01-01

    Since many type 2 diabetes patients experience postprandial hypotension, the aim of this study was to unravel meal-related changes in systemic hemodynamics and autonomic nervous system (ANS)-balance. Forty-two age-matched males (15 type 2 diabetes; 12 metabolic syndrome; 15 controls) without overt

  16. The thick left ventricular wall of the giraffe heart normalises wall tension, but limits stroke volume and cardiac output

    DEFF Research Database (Denmark)

    Smerup, Morten Holdgaard; Damkjær, Mads; Brøndum, Emil

    2016-01-01

    Giraffes - the tallest extant animals on Earth - are renowned for their high central arterial blood pressure, which is necessary to secure brain perfusion. The pressure which may exceed 300 mmHg has historically been attributed to an exceptionally large heart. Recently, this has been refuted...... by several studies demonstrating that the mass of giraffe heart is similar to that of other mammals when expressed relative to body mass. It remains enigmatic, however, how the normal-sized giraffe heart generates such massive arterial pressures.We hypothesized that giraffe hearts have a small...... intraventricular cavity and a relatively thick ventricular wall, allowing for generation of high arterial pressures at normal left ventricular wall tension. In nine anaesthetized giraffes (495±38 kg), we determined in vivo ventricular dimensions using echocardiography along with intraventricular and aortic...

  17. Relating the environmental impact of consumption to household expenditures. An input-output analysis

    International Nuclear Information System (INIS)

    Kerkhof, Annemarie C.; Nonhebel, Sanderine; Moll, Henri C.

    2009-01-01

    In this paper we evaluate the relationships between household expenditures and the environmental impact categories climate change, acidification, eutrophication and smog formation, by combining household expenditures with environmentally extended input-output analysis. Expenditure elasticities are examined with regression analysis, and are compared and interpreted on the basis of insight at the product level. With data from the Netherlands in the year 2000, we find that environmental impact increases with increasing household expenditures, although the degree to which the environmental impact increases differs per impact category. Climate change and eutrophication increase less than proportionally with increasing expenditures. Acidification increases nearly proportionally with increasing expenditures, whereas smog formation increases more than proportionally. It appears that the mix of necessities and luxuries to which an environmental impact is related is essential in explaining the relationship. (author)

  18. Direct recording of cardiac output- and venous return-curves in the dog heart-lung preparation for a graphical analysis of the effects of cardioactive drugs.

    Science.gov (United States)

    Ishikawa, N; Taki, K; Hojo, Y; Hagino, Y; Shigei, T

    1978-09-01

    The dog heart-lung preparations were prepared. The "equilibrium point", which could be defined as the point at which the cardiac output (CO)-curve and the venous return (VR)-curve crossed, when the CO and VR were plotted against the right atrial pressure, was recorded directly by utilizing an X-Y recorder. The CO-curve was obtained, as a locus of the equilibrium point, by raising and lowering the level of blood in the venous reservoir (competence test). The meaning of the procedure was shown to increase or decrease the mean systemic pressure, and to cause the corresponding parallel shift in the VR-curve. The VR-curve was obtained by changing myocardial contractility. When heart failure was induced by pentobarbital or by chloroform, the equilibrium point shifted downwards to the right, depicting the VR-curve. During development of the failure, the slopes of CO-curves decreased gradually. Effects of cinobufagin and norepinephrine were also analyzed. Utilization of the X-Y recorder enabled us to settle the uniform experimental conditions more easily, and to follow the effects of drugs continuously on a diagram equating the CO- and VR-curves (Gyton's scheme).

  19. G16R single nucleotide polymorphism but not haplotypes of the ß2-adrenergic receptor gene alters cardiac output in humans

    DEFF Research Database (Denmark)

    Rokamp, Kim Z; Staalsø, Jonatan M; Gartmann, Martin

    2013-01-01

    Variation in genes encoding the ß2-adrenergic receptor (ADRB2) and angiotensin-converting enzyme (ACE) may influence Q¿ (cardiac output). The 46G>A (G16R) SNP (single nucleotide polymorphism) has been associated with ß2-mediated vasodilation, but the effect of ADRB2 haplotypes on Q¿ has not been...... studied. Five SNPs within ADRB2 (46G>A, 79C>G, 491C>T, 523C>A and 1053G>C by a pairwise tagging principle) and the I/D (insertion/deletion) polymorphism in ACE were genotyped in 143 subjects. Cardiovascular variables were evaluated by the Model flow method at rest and during incremental cycling exercise...... V¿O2 (oxygen uptake) in G16G subjects, but the increase was 0.5 (0.0-0.9) l/min lower in Arg16 carriers (P=0.035). A similar effect size was observed for the Arg16 haplotypes ACCCG and ACCCC. No interaction was found between ADRB2 and ACE polymorphisms. During exercise, the increase in Q¿ was 0...

  20. Phosphodiesterase inhibitor KMUP-3 displays cardioprotection via protein kinase G and increases cardiac output via G-protein-coupled receptor agonist activity and Ca2+ sensitization

    Directory of Open Access Journals (Sweden)

    Chung-Pin Liu

    2016-02-01

    Full Text Available KMUP-3 (7-{2-[4-(4-nitrobenzene piperazinyl]ethyl}-1, 3-dimethylxanthine displays cardioprotection and increases cardiac output, and is suggested to increase cardiac performance and improve myocardial infarction. To determine whether KMUP-3 improves outcomes in hypoperfused myocardium by inducing Ca2+ sensitization to oppose protein kinase (PKG-mediated Ca2+ blockade, we measured left ventricular systolic blood pressure, maximal rates of pressure development, mean arterial pressure and heart rate in rats, and measured contractility and expression of PKs/RhoA/Rho kinase (ROCKII in beating guinea pig left atria. Hemodynamic changes induced by KMUP-3 (0.5–3.0 mg/kg, intravenously were inhibited by Y27632 [(R-(+-trans-4-1-aminoethyl-N-(4-Pyridyl cyclohexane carboxamide] and ketanserin (1 mg/kg, intravenously. In electrically stimulated left guinea pig atria, positive inotropy induced by KMUP-3 (0.1–100μM was inhibited by the endothelial NO synthase (eNOS inhibitors N-nitro-l-arginine methyl ester (L-NAME and 7-nitroindazole, cyclic AMP antagonist SQ22536 [9-(terahydro-2-furanyl-9H-purin-6-amine], soluble guanylyl cyclase (sGC antagonist ODQ (1H-[1,2,4] oxadiazolo[4,3-a] quinoxalin-1-one, RhoA inhibitor C3 exoenzyme, β-blocker propranolol, 5-hydroxytryptamine 2A antagonist ketanserin, ROCK inhibitor Y27632 and KMUP-1 (7-{2-[4-(2-chlorobenzene piperazinyl]ethyl}-1, 3-dimethylxanthine at 10μM. Western blotting assays indicated that KMUP-3 (0.1–10μM increased PKA, RhoA/ROCKII, and PKC translocation and CIP-17 (an endogenous 17-kDa inhibitory protein activation. In spontaneous right atria, KMUP-3 induced negative chronotropy that was blunted by 7-nitroindazole and atropine. In neonatal myocytes, L-NAME inhibited KMUP-3-induced eNOS phosphorylation and RhoA/ROCK activation. In H9c2 cells, Y-27632 (50μM and PKG antagonist KT5823 [2,3,9,10,11,12-hexahydro-10R- methoxy-2,9-dimethyl-1-oxo-9S,12R-epoxy-1H-diindolo(1,2,3-fg:3′,2′,1

  1. Fatty old hearts: role of cardiac lipotoxicity in age-related cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Konstantinos Drosatos

    2016-08-01

    Full Text Available Age-related cardiomyopathy accounts for a significant part of heart failure cases. Imbalance of the energetic equilibrium of the heart along with mitochondrial dysfunction and impaired β-adrenergic receptor signaling contributes in the aggravation of cardiac function in the elderly. In this review article, studies that correlate cardiac aging with lipotoxicity are summarized. The involvement of inhibition of peroxisome proliferator-activated receptor-α, β-adrenergic receptor desensitization, and mitochondrial dysfunction as underlying mechanisms for the lipid-driven age-related cardiomyopathy are presented with the aim to indicate potential therapeutic targets for cardiac aging.

  2. Evaluation of simplified two source model for relative electron output factor of irregular block shape

    International Nuclear Information System (INIS)

    Lo, Y. E.; Yi, B. Y.; Ahn, S. D.; Kim, J. H.; Lee, S. W.; Choi, E. K.

    2002-01-01

    A practical calculation algorithm which calculates the relative output factor (ROF) for electron irregular shaped-field has been developed and evaluated the accuracy and the effectiveness of the algorithm by comparing the measurements and the calculation results for irregular fields used in clinic. The algorithm assumes that the electron dose can be express as sum of the primary source component and the scattered component from the shielding block. The primary source is assumed to have Gaussian distribution, while the scattered component follows the inverse square law. Depth and angular dependency of the primary and the scattered are ignored for maximizing the practicability by reducing the number of parameters for the algorithm. Electron dose can be calculated with three parameters such as, the effective source distance, the variance of primary source, and the scattering power of the block. The coefficients are obtained from the square shaped-block measurements and these are confirmed from the rectangular or irregular shaped-fields. The results showed less than 1.5% difference between the calculation and measurements. The algorithm is proved to be practical, since one can acquire the full parameters with minimum measurements and generates accurate results within the clinically acceptable range

  3. Strategy for clinical evaluation and screening of sudden cardiac death relatives

    DEFF Research Database (Denmark)

    Ferrero-Miliani, Laura; Holst, Anders Gaarsdal; Pehrson, Steen

    2010-01-01

    Sudden cardiac death (SCD) may be the first and final manifestation of several heart diseases. In the young, SCD is often caused by a hereditary cardiac disease. As the most frequently seen inherited cardiac diseases have an autosomal-dominant pattern of inheritance, half of the first......-degree relatives are at risk of having or developing the same disease. Therefore, screening of these high-risk relatives is a rational approach to reduce the incidence of SCD. To offer family screening and counseling, the cause of death should be carefully established. Autopsy is only performed in a limited number...... a limited number of inherited cardiac diseases associated with SCD are without any structural changes. In other cases, the autopsy may reveal noncardiac causes of death, which is also important for reassuring the relatives. However, in cases with no autopsy or negative findings, thorough clinical...

  4. Relating the environmental impact of consumption to household expenditures : An input-output analysis

    NARCIS (Netherlands)

    Kerkhof, Annemarie C.; Nonhebel, Sanderine; Moll, Henri C.

    2009-01-01

    In this paper we evaluate the relationships between household expenditures and the environmental impact categories climate change, acidification, eutrophication and smog formation, by combining household expenditures with environmentally extended input–output analysis. Expenditure elasticities are

  5. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients.

    Science.gov (United States)

    Wagner, Julia Y; Körner, Annmarie; Schulte-Uentrop, Leonie; Kubik, Mathias; Reichenspurner, Hermann; Kluge, Stefan; Reuter, Daniel A; Saugel, Bernd

    2018-04-01

    The CNAP technology (CNSystems Medizintechnik AG, Graz, Austria) allows continuous noninvasive arterial pressure waveform recording based on the volume clamp method and estimation of cardiac output (CO) by pulse contour analysis. We compared CNAP-derived CO measurements (CNCO) with intermittent invasive CO measurements (pulmonary artery catheter; PAC-CO) in postoperative cardiothoracic surgery patients. In 51 intensive care unit patients after cardiothoracic surgery, we measured PAC-CO (criterion standard) and CNCO at three different time points. We conducted two separate comparative analyses: (1) CNCO auto-calibrated to biometric patient data (CNCO bio ) versus PAC-CO and (2) CNCO calibrated to the first simultaneously measured PAC-CO value (CNCO cal ) versus PAC-CO. The agreement between the two methods was statistically assessed by Bland-Altman analysis and the percentage error. In a subgroup of patients, a passive leg raising maneuver was performed for clinical indications and we present the changes in PAC-CO and CNCO in four-quadrant plots (exclusion zone 0.5 L/min) in order to evaluate the trending ability of CNCO. The mean difference between CNCO bio and PAC-CO was +0.5 L/min (standard deviation ± 1.3 L/min; 95% limits of agreement -1.9 to +3.0 L/min). The percentage error was 49%. The concordance rate was 100%. For CNCOcal, the mean difference was -0.3 L/min (±0.5 L/min; -1.2 to +0.7 L/min) with a percentage error of 19%. In this clinical study in cardiothoracic surgery patients, CNCO cal showed good agreement when compared with PAC-CO. For CNCO bio , we observed a higher percentage error and good trending ability (concordance rate 100%).

  6. Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial.

    Science.gov (United States)

    Lilot, Marc; Bellon, Amandine; Gueugnon, Marine; Laplace, Marie-Christine; Baffeleuf, Bruno; Hacquard, Pauline; Barthomeuf, Felicie; Parent, Camille; Tran, Thomas; Soubirou, Jean-Luc; Robinson, Philip; Bouvet, Lionel; Vassal, Olivia; Lehot, Jean-Jacques; Piriou, Vincent

    2018-01-27

    An intraoperative automated closed-loop system for goal-directed fluid therapy has been successfully tested in silico, in vivo and in a clinical case-control matching. This trial compared intraoperative cardiac output (CO) in patients managed with this closed-loop system versus usual practice in an academic medical center. The closed-loop system was connected to a CO monitoring system and delivered automated colloid fluid boluses. Moderate to high-risk abdominal surgical patients were randomized either to the closed-loop or the manual group. Intraoperative final CO was the primary endpoint. Secondary endpoints were intraoperative overall mean cardiac index (CI), increase from initial to final CI, intraoperative fluid volume and postoperative outcomes. From January 2014 to November 2015, 46 patients were randomized. There was a lower initial CI (2.06 vs. 2.51 l min -1 m -2 , p = 0.042) in the closed-loop compared to the control group. No difference in final CO and in overall mean intraoperative CI was observed between groups. A significant relative increase from initial to final CI values was observed in the closed-loop but not the control group (+ 28.6%, p = 0.006 vs. + 1.2%, p = 0.843). No difference was found for intraoperative fluid management and postoperative outcomes between groups. There was no significant impact on the primary study endpoint, but this was found in a context of unexpected lower initial CI in the closed-loop group.Trial registry number ID-RCB/EudraCT: 2013-A00770-45. ClinicalTrials.gov Identifier NCT01950845, date of registration: 17 September 2013.

  7. Myocardin-related transcription factors are required for cardiac development and function

    Science.gov (United States)

    Mokalled, Mayssa H.; Carroll, Kelli J.; Cenik, Bercin K.; Chen, Beibei; Liu, Ning; Olson, Eric N.; Bassel-Duby, Rhonda

    2016-01-01

    Myocardin-Related Transcription Factors A and B (MRTF-A and MRTF-B) are highly homologous proteins that function as powerful coactivators of serum response factor (SRF), a ubiquitously expressed transcription factor essential for cardiac development. The SRF/MRTF complex binds to CArG boxes found in the control regions of genes that regulate cytoskeletal dynamics and muscle contraction, among other processes. While SRF is required for heart development and function, the role of MRTFs in the developing or adult heart has not been explored. Through cardiac-specific deletion of MRTF alleles in mice, we show that either MRTF-A or MRTF-B is dispensable for cardiac development and function, whereas deletion of both MRTF-A and MRTF-B causes a spectrum of structural and functional cardiac abnormalities. Defects observed in MRTF-A/B null mice ranged from reduced cardiac contractility and adult onset heart failure to neonatal lethality accompanied by sarcomere disarray. RNA-seq analysis on neonatal hearts identified the most altered pathways in MRTF double knockout hearts as being involved in cytoskeletal organization. Together, these findings demonstrate redundant but essential roles of the MRTFs in maintenance of cardiac structure and function and as indispensible links in cardiac cytoskeletal gene regulatory networks. PMID:26386146

  8. Sports-Related Sudden Cardiac Injury or Death.

    Science.gov (United States)

    Greene, Elizabeth Anne; Punnoose, Ann

    2015-12-01

    Symptoms such as syncope and chest pain, especially if they are accompanied by palpitations or occur with exercise in any combination, require cardiac evaluation before adolescent athletes are allowed to return to the sports field. Some life-threatening conditions will likely be associated with a family history of HCM or LQTS, but the family history may not be discovered at the first medical visit. A family history of CPVT, for example, is hard to elicit unless this diagnosis has already been established in an affected family member. The keys will be the timing of symptoms and the documentation of arrhythmia with exercise. The ECG at baseline in CPVT may be deceptively normal. Hypertrophic cardiomyopathy is progressive, so evaluation during early childhood may be negative. Long QT syndrome may not always result in an abnormal ECG, even in genetically positive individuals. A high index of suspicion is needed to make these diagnoses, especially if the family history is not available.

  9. Spectral analysis of the EEG during halothane anaesthesia: Input-output relations

    NARCIS (Netherlands)

    Silva, F.H. Lopes da; Smith, N. Ty; Zwart, Aart; Nichols, W.W.

    1. 1. The “Halothane-brain compartment” system was investigated in dogs. The input was the inspired concentration of Halothane. The output was the intensity of EEG spectral components. The EEG was analysed by a hybrid system (analogue filters and digital integration in a small computer). For the

  10. The output, incomes and assets-capital relations in individual farms

    Directory of Open Access Journals (Sweden)

    Roma Ryś-Jurek

    2009-01-01

    Full Text Available In this article an attempt was made to analyse the output, incomes as well as other components of assets and sources that provided their financing in Polish individual farms, in comparison with farms from other EU countries. A special emphasis was put on examination of the interrelations between income, output and stocks observed within individual farms. Research was based on the FADN database that included basic information about average individual farms in years 2004-2006. The research showed, that (among other things the average output and family farm income were three times lower in Poland than the average in the Union. Also the increase of income was possible only thanks to the subsidies from the Union. According to the regression models, in Poland the positive influence on the increase of family farm income had stocks, crops and livestock output. While in the EU positive influence had crops and livestock production and negative influence had the stocks on an income’s growth.

  11. Somatotype variables related to strength and power output in male basketball players.

    Science.gov (United States)

    Buśko, Krzysztof; Pastuszak, Anna; Lipińska, Monika; Lipińska, Marta; Gryko, Karol

    2017-01-01

    The purpose of this study was to investigate the relationship between somatotype, muscular strength, power output measured in maximal cycle ergometer exercise bouts, and maximal power output and height of rise of the body mass centre (jump height) measured in akimbo counter movement jump (ACMJ), counter movement jump (CMJ) and spike jump (SPJ), in male basketball players. Thirteen male basketball players (second division, age 19.4 ± 0.8 years, body height 192.9 ± 5.6 cm, body mass 88.8 ± 8.6 kg, training experience 9.3 ± 0.8 years) participated in the study. Somatotype was determined using the Heath-Carter method. Maximal joint torques were measured under static conditions. Power output was measured in 2 maximal cycle ergometer exercise bouts, 10 seconds each, with increasing external loads equal to 7.5 and 10.0% of the body weight (BW). All jump trials (ACMJ, CMJ and SPJ) were performed on a force plate. The mean somatotype of basketball players amounted to: 2.8-4.2-3.2. The sum of the joint torques for left and right lower extremities (0.613), trunk (0.631) and all six measured muscle groups (0.647) were significantly correlated (p jump during ACMJ, CMJ and SPJ trials. The power output measured in maximal cycle ergometer exercise bouts with increasing external loads was significantly correlated (p basketball players' anthropometric characteristics can influence their level of performance but it is not a decisive factor.

  12. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review.

    Science.gov (United States)

    Cornette, J; Laker, S; Jeffery, B; Lombaard, H; Alberts, A; Rizopoulos, D; Roos-Hesselink, J W; Pattinson, R C

    2017-01-01

    Most severe pregnancy complications are characterized by profound hemodynamic disturbances, thus there is a need for validated hemodynamic monitoring systems for pregnant women. Pulmonary artery catheterization (PAC) using thermodilution is the clinical gold standard for the measurement of cardiac output (CO), however this reference method is rarely performed owing to its invasive nature. Transthoracic echocardiography (TTE) allows non-invasive determination of CO. We aimed to validate TTE against PAC for the determination of CO in severely ill pregnant women. This study consisted of a meta-analysis combining data from a prospective study and a systematic review. The prospective arm was conducted in Pretoria, South Africa, in 2003. Women with severe pregnancy complications requiring invasive monitoring with PAC according to contemporary guidelines were included. TTE was performed within 15 min of PAC and the investigator was blinded to the PAC measurements. Comparative measurements were extracted from similar studies retrieved from a systematic review of the literature and added to a database. Simultaneous CO measurements by TTE and PAC were compared. Agreement between methods was assessed using Bland-Altman statistics and intraclass correlation coefficients (ICC). Thirty-four comparative measurements were included in the meta-analysis. Mean CO values obtained by PAC and TTE were 7.39 L/min and 7.18 L/min, respectively. The bias was 0.21 L/min with lower and upper limits of agreement of -1.18 L/min and 1.60 L/min, percentage error was 19.1%, and ICC between the two methods was 0.94. CO measurements by TTE show excellent agreement with those obtained by PAC in pregnant women. Given its non-invasive nature and availability, TTE could be considered as a reference for the validation of other CO techniques in pregnant women. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Las complicaciones del embarazo más graves se caracterizan por trastornos hemodin

  13. The relations between the output, income and stock in agricultural farms

    Directory of Open Access Journals (Sweden)

    Roma Ryś-Jurek

    2009-01-01

    Full Text Available In this article an attempt was made to analyse the stock, output, and incomes in individual agricultural farms in Poland, in comparison with farms from the other EU countries in the year 2006. Research was based on the FADN database. The research showed, that (among other things the Polish average individual farm had a four time lower the balance’s sum than the medium one in the EU, and the average output and family farm income were about three times lower in Poland than the average in the Union. The highest share of stock in the balance’s sum in Poland three direction of production had: permanent crops combined, specialist other field crops and specialist orchards – fruits. While in the Union the highest stock had the specialist wine. According to the regression’s models, in Poland the positive influence on the increase of family farm income had stock, crops and livestock output. In the Union positive influence on an income’s growth had crops and livestock production and negative influence had the stock.

  14. Cyberknife Relative Output Factor measurements using fiber-coupled luminescence, MOSFETS and RADPOS dosimetry system

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Vandervoort, E.

    2012-01-01

    from 5 to 60 mm. ROFs were also measured using a mobileMOSFET system (Best Medical Canada) and EBT1 and EBT2 GAFCHROMIC® (ISP, Ashland) radiochromic films. For cone sizes 12.5–60 mm all detector results were in agreement within the measurement uncertainty. The microMOSFET/RADPOS measurements (published.......3% and 0.865 ± 0.3% for 5, 7.5 and 10 mm cones. Our study shows that the microMOSFET/RADPOS and optical fiber‐coupled RL dosimetry system are well suited for Cyberknife cone output factors measurements over the entire range of field sizes, provided that appropriate correction factors are applied...

  15. Analysis of network motifs in cellular regulation: Structural similarities, input-output relations and signal integration.

    Science.gov (United States)

    Straube, Ronny

    2017-12-01

    Much of the complexity of regulatory networks derives from the necessity to integrate multiple signals and to avoid malfunction due to cross-talk or harmful perturbations. Hence, one may expect that the input-output behavior of larger networks is not necessarily more complex than that of smaller network motifs which suggests that both can, under certain conditions, be described by similar equations. In this review, we illustrate this approach by discussing the similarities that exist in the steady state descriptions of a simple bimolecular reaction, covalent modification cycles and bacterial two-component systems. Interestingly, in all three systems fundamental input-output characteristics such as thresholds, ultrasensitivity or concentration robustness are described by structurally similar equations. Depending on the system the meaning of the parameters can differ ranging from protein concentrations and affinity constants to complex parameter combinations which allows for a quantitative understanding of signal integration in these systems. We argue that this approach may also be extended to larger regulatory networks. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A Comparison of the Reproductive Output Among the Relatives of Samoan Androphilic Fa'afafine and Gynephilic Men.

    Science.gov (United States)

    Semenyna, Scott W; Petterson, Lanna J; VanderLaan, Doug P; Vasey, Paul L

    2017-01-01

    The sexually antagonistic gene hypothesis (SAGH) for male androphilia posits that genes associated with androphilia (i.e., sexual attraction to adult males) will result in lowered reproduction when present in males, but increased reproduction when present in females. Findings derived from some Western European samples furnish support for the SAGH; however, results from studies conducted in other regions of the world have been more equivocal. Our previous research in Samoa indicated that the mothers as well as the maternal and paternal grandmothers of androphilic males (known locally as fa'afafine) exhibit elevated reproductive output when compared to the relatives of gynephilic men (i.e., males that are sexually attracted to adult females). The present replication study tested the SAGH in Samoa using a sample that was 122 % larger than the one previously studied by our group (VanderLaan, Forrester, Petterson, & Vasey, 2012). In line with the predictions of the SAGH, we hypothesized that the grandmothers, aunts, and mothers of fa'afafine would show elevated reproductive output compared to those of Samoan gynephilic men. Data were collected from 191 fa'afafine and 191 gynephilic men on the reproductive output of their paternal and maternal biological relatives (i.e., mothers, grandmothers, aunts, uncles). The mothers and maternal grandmothers of fa'afafine showed elevated reproductive output compared to those of gynephilic men. The paternal grandmother effect was not replicated. Although these results are consistent with the SAGH, a lack of difference in the reproductive output of aunts renders support for the SAGH in Samoa equivocal.

  17. Age-related changes of neurochemically different subpopulations of cardiac spinal afferent neurons in rats.

    Science.gov (United States)

    Guić, Maja Marinović; Runtić, Branka; Košta, Vana; Aljinović, Jure; Grković, Ivica

    2013-08-01

    This study investigated the effect of aging on cardiac spinal afferent neurons in the rat. A patch loaded with retrograde tracer Fast Blue (FB) was applied to all chambers of the rat heart. Morphological and neurochemical characteristics of labeled cardiac spinal afferent neurons were assessed in young (2 months) and old (2 years) rats using markers for likely unmyelinated (isolectin B4; IB4) and myelinated (neurofilament 200; N52) neurons. The number of cardiac spinal afferent neurons decreased in senescence to 15% of that found in young rats (1604 vs. 248). The size of neuronal soma as well as proportion of IB4+ neurons increased significantly, whereas the proportion of N52+ neurons decreased significantly in senescence. Unlike somatic spinal afferents, neurochemically different populations of cardiac spinal afferent neurons experience morphological and neurochemical changes related to aging. A major decrease in total number of cardiac spinal afferent neurons occurs in senescence. The proportion of N52+ neurons decreased in senescence, but it seems that nociceptive innervation is preserved due to increased proportion and size of IB4+ unmyelinated neurons. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Age-Related Differences of Maximum Phonation Time in Patients after Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Kazuhiro P. Izawa

    2017-12-01

    Full Text Available Background and aims: Maximum phonation time (MPT, which is related to respiratory function, is widely used to evaluate maximum vocal capabilities, because its use is non-invasive, quick, and inexpensive. We aimed to examine differences in MPT by age, following recovery phase II cardiac rehabilitation (CR. Methods: This longitudinal observational study assessed 50 consecutive cardiac patients who were divided into the middle-aged group (<65 years, n = 29 and older-aged group (≥65 years, n = 21. MPTs were measured at 1 and 3 months after cardiac surgery, and were compared. Results: The duration of MPT increased more significantly from month 1 to month 3 in the middle-aged group (19.2 ± 7.8 to 27.1 ± 11.6 s, p < 0.001 than in the older-aged group (12.6 ± 3.5 to 17.9 ± 6.0 s, p < 0.001. However, no statistically significant difference occurred in the % change of MPT from 1 month to 3 months after cardiac surgery between the middle-aged group and older-aged group, respectively (41.1% vs. 42.1%. In addition, there were no significant interactions of MPT in the two groups for 1 versus 3 months (F = 1.65, p = 0.20. Conclusion: Following phase II, CR improved MPT for all cardiac surgery patients.

  19. Age-Related Differences of Maximum Phonation Time in Patients after Cardiac Surgery.

    Science.gov (United States)

    Izawa, Kazuhiro P; Kasahara, Yusuke; Hiraki, Koji; Hirano, Yasuyuki; Watanabe, Satoshi

    2017-12-21

    Background and aims: Maximum phonation time (MPT), which is related to respiratory function, is widely used to evaluate maximum vocal capabilities, because its use is non-invasive, quick, and inexpensive. We aimed to examine differences in MPT by age, following recovery phase II cardiac rehabilitation (CR). Methods: This longitudinal observational study assessed 50 consecutive cardiac patients who were divided into the middle-aged group (<65 years, n = 29) and older-aged group (≥65 years, n = 21). MPTs were measured at 1 and 3 months after cardiac surgery, and were compared. Results: The duration of MPT increased more significantly from month 1 to month 3 in the middle-aged group (19.2 ± 7.8 to 27.1 ± 11.6 s, p < 0.001) than in the older-aged group (12.6 ± 3.5 to 17.9 ± 6.0 s, p < 0.001). However, no statistically significant difference occurred in the % change of MPT from 1 month to 3 months after cardiac surgery between the middle-aged group and older-aged group, respectively (41.1% vs. 42.1%). In addition, there were no significant interactions of MPT in the two groups for 1 versus 3 months (F = 1.65, p = 0.20). Conclusion: Following phase II, CR improved MPT for all cardiac surgery patients.

  20. Critical incidents related to cardiac arrests reported to the Danish Patient Safety Database

    DEFF Research Database (Denmark)

    Andersen, Peter Oluf; Maaløe, Rikke; Andersen, Henning Boje

    2010-01-01

    Background Critical incident reports can identify areas for improvement in resuscitation practice. The Danish Patient Safety Database is a mandatory reporting system and receives critical incident reports submitted by hospital personnel. The aim of this study is to identify, analyse and categorize...... critical incidents related to cardiac arrests reported to the Danish Patient Safety Database. Methods The search terms “cardiac arrest” and “resuscitation” were used to identify reports in the Danish Patient Safety Database. Identified critical incidents were then classified into categories. Results One...

  1. Evolution of echocardiography in subclinical detection of cancer therapy-related cardiac dysfunction.

    Science.gov (United States)

    Moudgil, Rohit; Hassan, Saamir; Palaskas, Nicolas; Lopez-Mattei, Juan; Banchs, Jose; Yusuf, Syed Wamique

    2018-05-11

    Cancer therapies have resulted in increased survivorship in oncological patients. However, the benefits have been marred by the development of premature cardiovascular disease. The current definition outlines measurement of ejection fraction as a mean to diagnose cancer therapeutic-related cardiac dysfunction (CTRCD); however, up to 58% of the patients do not regain their cardiac function after the CTRCD diagnosis, despite therapeutic interventions. Therefore, there has been a growing interest in the markers for early myocardial changes (ie, changes with normal left ventricular ejection fraction [LVEF]) that may predict the development of subsequent left ventricular ejection fraction reduction or progression to heart failure. This review will highlight the use of diastolic parameters, tissue Doppler imaging (TDI), and speckle tracking echocardiogram (STE) as emerging technologies which can potentially detect cardiac dysfunction thereby stratifying patients for cardioprotective therapies. The goal of this manuscript was to highlight the concepts and discuss the current controversies surrounding these echocardiographic imaging modalities. © 2018 Wiley Periodicals, Inc.

  2. Conditioning techniques and ischemic reperfusion injury in relation to on-pump cardiac surgery

    DEFF Research Database (Denmark)

    Holmberg, Fredrik Eric Olof; Ottas, Konstantin Alex; Andreasen, Charlotte

    2014-01-01

    OBJECTIVES: The objective was to investigate the potential protective effects of two conditioning methods, on myocardial ischemic and reperfusion injury in relation to cardiac surgery. DESIGN: Totally 68 patients were randomly assigned to either a control group (n = 23), a remote ischemic...

  3. Tacrolimus-related hypertrophic cardiomyopathy in an adult cardiac transplant patient

    Institute of Scientific and Technical Information of China (English)

    LIU Tong; DONG Jian-zeng; GAO Yun; GAO Yu-long; CHENG Yu-tong; WANG Su; LI Zhi-zhong; ZHANG Hai-bo; MENG Xu; MA Chang-sheng

    2012-01-01

    Left ventricular hypertrophy associated with the use of tacrolimus is a rare complication of solid organ transplantation in adult recipients.We present a cardiac transplant recipient who developed severe concentric left ventricular hypertrophy with congestive heart failure related to myocardial hypertrophy on tacrolimus.Hypertrophy improved when the drug was discontinued and replaced with sirolimus.

  4. Anesthesiologist- and System-Related Risk Factors for Risk-Adjusted Pediatric Anesthesia-Related Cardiac Arrest.

    Science.gov (United States)

    Zgleszewski, Steven E; Graham, Dionne A; Hickey, Paul R; Brustowicz, Robert M; Odegard, Kirsten C; Koka, Rahul; Seefelder, Christian; Navedo, Andres T; Randolph, Adrienne G

    2016-02-01

    Pediatric anesthesia-related cardiac arrest (ARCA) is an uncommon but potentially preventable adverse event. Infants and children with more severe underlying disease are at highest risk. We aimed to identify system- and anesthesiologist-related risk factors for ARCA. We analyzed a prospectively collected patient cohort data set of anesthetics administered from 2000 to 2011 to children at a large tertiary pediatric hospital. Pre-procedure systemic disease level was characterized by ASA physical status (ASA-PS). Two reviewers independently reviewed cardiac arrests and categorized their anesthesia relatedness. Factors associated with ARCA in the univariate analyses were identified for reevaluation after adjustment for patient age and ASA-PS. Cardiac arrest occurred in 142 of 276,209 anesthetics (incidence 5.1/10,000 anesthetics); 72 (2.6/10,000 anesthetics) were classified as anesthesia-related. In the univariate analyses, risk of ARCA was much higher in cardiac patients and for anesthesiologists with lower annual caseload and/or fewer annual days delivering anesthetics (all P risk adjustment for ASA-PS ≥ III and age ≤ 6 months, however, the association with lower annual days delivering anesthetics remained (P = 0.03), but the other factors were no longer significant. Case-mix explained most associations between higher risk of pediatric ARCA and anesthesiologist-related variables at our institution, but the association with fewer annual days delivering anesthetics remained. Our findings highlight the need for rigorous adjustment for patient risk factors in anesthesia patient safety studies.

  5. Respiratory muscle strength in relation to sarcopenia in elderly cardiac patients.

    Science.gov (United States)

    Izawa, Kazuhiro P; Watanabe, Satoshi; Oka, Koichiro; Kasahara, Yusuke; Morio, Yuji; Hiraki, Koji; Hirano, Yasuyuki; Omori, Yutaka; Suzuki, Norio; Kida, Keisuke; Suzuki, Kengo; Akashi, Yoshihiro J

    2016-12-01

    Little information exists on the relation between respiratory muscle strength such as maximum inspiratory muscle pressure (MIP) and sarcopenia in elderly cardiac patients. The present study aimed to determine the differences in MIP, and cutoff values for MIP according to sarcopenia in elderly cardiac patients. We enrolled 63 consecutive elderly male patients aged ≥65 years with cardiac disease in this cross-sectional study. Sarcopenia was defined based on the European Working Group on Sarcopenia in Older People algorithm, and, accordingly, the patients were divided into two groups: the sarcopenia group (n = 24) and non-sarcopenia group (n = 39). The prevalence of sarcopenia in cardiac patients and MIP in the patients with and without sarcopenia were assessed to determine cutoff values of MIP. After adjustment for body mass index, the MIP in the sarcopenia group was significantly lower than that in the non-sarcopenia group (54.7 ± 36.8 cmH 2 O; 95 % CI 42.5-72.6 vs. 80.7 ± 34.7 cmH 2 O; 95 % CI 69.5-92.0; F = 4.89, p = 0.029). A receiver-operating characteristic curve analysis of patients with and without sarcopenia identified a cutoff value for MIP of 55.6 cmH 2 O, with a sensitivity of 0.76, 1-specificity of 0.37, and AUC of 0.70 (95 % CI 0.56-0.83; p = 0.01) in the study patients. Compared with elderly cardiac patients without sarcopenia, MIP in those with sarcopenia may be negatively affected. The MIP cutoff value reported here may be a useful minimum target value for identifying elderly male cardiac patients with sarcopenia.

  6. Input/output manual of light water reactor fuel analysis code FEMAXI-7 and its related codes

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Motoe; Udagawa, Yutaka; Nagase, Fumihisa [Japan Atomic Energy Agency, Nuclear Safety Research Center, Tokai, Ibaraki (Japan); Saitou, Hiroaki [ITOCHU Techno-Solutions Corporation, Tokyo (Japan)

    2013-10-15

    A light water reactor fuel analysis code FEMAXI-7 has been developed, as an extended version from the former version FEMAXI-6, for the purpose of analyzing the fuel behavior in normal conditions and in anticipated transient conditions. Numerous functional improvements and extensions have been incorporated in FEMAXI-7, which are fully disclosed in the code model description published in the form of another JAEA-Data/Code report. The present manual, which is the very counterpart of this description document, gives detailed explanations of files and operation method of FEMAXI-7 code and its related codes, methods of input/output, sample Input/Output, methods of source code modification, subroutine structure, and internal variables in a specific manner in order to facilitate users to perform fuel analysis by FEMAXI-7. (author)

  7. Input/output manual of light water reactor fuel analysis code FEMAXI-7 and its related codes

    International Nuclear Information System (INIS)

    Suzuki, Motoe; Udagawa, Yutaka; Nagase, Fumihisa; Saitou, Hiroaki

    2013-10-01

    A light water reactor fuel analysis code FEMAXI-7 has been developed, as an extended version from the former version FEMAXI-6, for the purpose of analyzing the fuel behavior in normal conditions and in anticipated transient conditions. Numerous functional improvements and extensions have been incorporated in FEMAXI-7, which are fully disclosed in the code model description published in the form of another JAEA-Data/Code report. The present manual, which is the very counterpart of this description document, gives detailed explanations of files and operation method of FEMAXI-7 code and its related codes, methods of input/output, sample Input/Output, methods of source code modification, subroutine structure, and internal variables in a specific manner in order to facilitate users to perform fuel analysis by FEMAXI-7. (author)

  8. Basic vital cardiac support. Training to relatives of patients with acute miocardial infarction

    OpenAIRE

    Brandy Viera Valdés; Paula Aguila Solis; Francisco Valladares Carvajal; Marcos D. Iraola Ferrer; Pablo. A. Rodríguez

    2006-01-01

    Background: Title: Basic vital cardiac support. Training to relatives of patients with acute miocardial infarction. The cardiorespiratory reanimation is a proved procedure that can save a human life in case of a cardiorespiratory stop. For three years it is imparted in the University Hospital of Cienfuegos, a training for this procedure, to the family of patients with sharp myocardic infarction. Objective: To evaluate the knowledge acquired by the relatives of the patients during the training...

  9. An Evaluative Measure for Outputs in Student-Run Public Relations Firms and Applied Courses

    Science.gov (United States)

    Deemer, Rebecca A.

    2012-01-01

    A valid, reliable survey instrument was created to be used by public relations student-run firms and other applied public relations courses to gauge client satisfaction. A series of focus groups and pilot tests were conducted to ascertain themes, refine questions, and then to refine the entire instrument. Six constructs to be measured, including…

  10. Aortic and Hepatic Contrast Enhancement During Hepatic-Arterial and Portal Venous Phase Computed Tomography Scanning: Multivariate Linear Regression Analysis Using Age, Sex, Total Body Weight, Height, and Cardiac Output.

    Science.gov (United States)

    Masuda, Takanori; Nakaura, Takeshi; Funama, Yoshinori; Higaki, Toru; Kiguchi, Masao; Imada, Naoyuki; Sato, Tomoyasu; Awai, Kazuo

    We evaluated the effect of the age, sex, total body weight (TBW), height (HT) and cardiac output (CO) of patients on aortic and hepatic contrast enhancement during hepatic-arterial phase (HAP) and portal venous phase (PVP) computed tomography (CT) scanning. This prospective study received institutional review board approval; prior informed consent to participate was obtained from all 168 patients. All were examined using our routine protocol; the contrast material was 600 mg/kg iodine. Cardiac output was measured with a portable electrical velocimeter within 5 minutes of starting the CT scan. We calculated contrast enhancement (per gram of iodine: [INCREMENT]HU/gI) of the abdominal aorta during the HAP and of the liver parenchyma during the PVP. We performed univariate and multivariate linear regression analysis between all patient characteristics and the [INCREMENT]HU/gI of aortic- and liver parenchymal enhancement. Univariate linear regression analysis demonstrated statistically significant correlations between the [INCREMENT]HU/gI and the age, sex, TBW, HT, and CO (all P linear regression analysis showed that only the TBW and CO were of independent predictive value (P linear regression analysis only the TBW and CO were significantly correlated with aortic and liver parenchymal enhancement; the age, sex, and HT were not. The CO was the only independent factor affecting aortic and liver parenchymal enhancement at hepatic CT when the protocol was adjusted for the TBW.

  11. Unit 16 - Output

    OpenAIRE

    Unit 16, CC in GIS; Star, Jeffrey L.

    1990-01-01

    This unit discusses issues related to GIS output, including the different types of output possible and the hardware for producing each. It describes text, graphic and digital data that can be generated by a GIS as well as line printers, dot matrix printers/plotters, pen plotters, optical scanners and cathode ray tubes (CRTs) as technologies for generating the output.

  12. Echocardiography in patients with complications related to pacemakers and cardiac defibrillators.

    Science.gov (United States)

    Almomani, Ahmed; Siddiqui, Khadija; Ahmad, Masood

    2014-03-01

    The evolving indications and uses for implantable cardiac devices have led to a significant increase in the number of implanted devices each year. Implantation of endocardial leads for permanent pacemakers and cardiac defibrillators can cause many delayed complications. Complications may be mechanical and related to the interaction of the device leads with the valves and endomyocardium, e.g., perforation, infection, and thrombosis, or due to the electrical pacing of the myocardium and conduction abnormalities, e.g., left ventricular dyssynchrony. Tricuspid regurgitation, another delayed complication in these patients, may be secondary to both mechanical and pacing effects of the device leads. Echocardiography plays an important role in the diagnosis of these device-related complications. Both two-dimensional transthoracic echocardiography and transesophageal echocardiography provide useful diagnostic information. Real time three-dimensional echocardiography is a novel technique that can further enhance the detection of lead-related complications. © 2013, Wiley Periodicals, Inc.

  13. Incidence and etiology of sports-related sudden cardiac death in Denmark--implications for preparticipation screening

    DEFF Research Database (Denmark)

    Holst, Anders Gaarsdal; Winkel, Bo Gregers; Theilade, Juliane

    2010-01-01

    BACKGROUND: Studies on incidences of sports-related sudden cardiac death (SrSCD) are few and data are needed for the discussion of preparticipation screening for cardiac disease. OBJECTIVE: We sought to chart the incidence and etiology of SrSCD in the young in Denmark (population 5.4 million...

  14. Cardiovascular Risk Factors in Primary Relatives of Sudden Cardiac Death Victims

    Science.gov (United States)

    1991-01-01

    hypertriglyceridemia and hypertension as risk factors in relatives of sudden death victims. The sample for both studies will be the same. 5 Chapter II The...provided most of the research information on SCD. Pathology of Sudden Cardiac Death There appear to be several different pathologic scenarios which render a...had severe two or three vessel disease. By comparison, 100 age matched controls who died of other causes, had a combined 27% incidence of two and

  15. Myocardin-related transcription factors are required for cardiac development and function

    OpenAIRE

    Mokalled, Mayssa H.; Carroll, Kelli J.; Cenik, Bercin K.; Chen, Beibei; Liu, Ning; Olson, Eric N.; Bassel-Duby, Rhonda

    2015-01-01

    Myocardin-Related Transcription Factors A and B (MRTF-A and MRTF-B) are highly homologous proteins that function as powerful coactivators of serum response factor (SRF), a ubiquitously expressed transcription factor essential for cardiac development. The SRF/MRTF complex binds to CArG boxes found in the control regions of genes that regulate cytoskeletal dynamics and muscle contraction, among other processes. While SRF is required for heart development and function, the role of MRTFs in the d...

  16. Quantifying federal funding and scholarly output related to the academic emergency medicine consensus conferences.

    Science.gov (United States)

    Nishijima, Daniel K; Dinh, Tu; May, Larissa; Yadav, Kabir; Gaddis, Gary M; Cone, David C

    2014-01-01

    Every year since 2000, Academic Emergency Medicine (AEM) has presented a one-day consensus conference to generate a research agenda for advancement of a scientific topic. One of the 12 annual issues of AEM is reserved for the proceedings of these conferences. The purpose of this study was to measure academic productivity of these conferences by evaluating subsequent federal research funding received by authors of conference manuscripts and calculating citation counts of conference papers. This was a cross-sectional study. In 2012, the NIH RePORTER system was searched to identify subsequent federal funding obtained by authors of the consensus conference issues from 2000 to 2010. Funded projects were coded as related or unrelated to conference topic. Citation counts for all conference manuscripts were quantified using Scopus and Google Scholar. Simple descriptive statistics were reported. Eight hundred fifty-two individual authors contributed to 280 papers published in the 11 consensus conference issues. One hundred thirty-seven authors (16%) obtained funding for 318 projects. A median of 22 topic-related projects per conference (range 10-97) accounted for a median of $20,488,331 per conference (range $7,779,512 to $122,918,205). The average (± SD) number of citations per paper was 15.7 ± 20.5 in Scopus and 23.7 ± 32.6 in Google Scholar. The authors of consensus conference manuscripts obtained significant federal grant support for follow-up research related to conference themes. In addition, the manuscripts generated by these conferences were frequently cited. Conferences devoted to research agenda development appear to be an academically worthwhile endeavor.

  17. Solving fatigue-related problems with cardiac arrest survivors living in the community.

    Science.gov (United States)

    Kim, Young Joo; Rogers, Joan C; Raina, Ketki D; Callaway, Clifton W; Rittenberger, Jon C; Leibold, Mary Lou; Holm, Margo B

    2017-09-01

    The aim was to describe fatigue-related problems reported by post-cardiac arrest adults with chronic fatigue and energy conservation strategies generated using an Energy Conservation plus Problem Solving Therapy intervention. Following an introduction to the intervention process outlined in a Participant Workbook, participants engaged in the telephone intervention by identifying one to two fatigue-related problems. They then brainstormed with the interventionist to identify potential strategies to reduce fatigue, tested them, and either modified the strategies or moved to the next problem over three to five sessions. Eighteen cardiac arrest survivors with chronic fatigue identified instrumental activities of daily living and leisure activities as fatigue-related activities more frequently than basic activities of daily living. Energy Conservation strategies used most frequently were: plan ahead, pace yourself, delegate to others, and simplify the task. Post-cardiac arrest adults living in the community with chronic fatigue can return to previous daily activities by using energy conservation strategies such as planning ahead, pacing tasks, delegating tasks, and simplifying tasks. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Relation between Peak Power Output in Sprint Cycling and Maximum Voluntary Isometric Torque Production.

    Science.gov (United States)

    Kordi, Mehdi; Goodall, Stuart; Barratt, Paul; Rowley, Nicola; Leeder, Jonathan; Howatson, Glyn

    2017-08-01

    From a cycling paradigm, little has been done to understand the relationships between maximal isometric strength of different single joint lower body muscle groups and their relation with, and ability to predict PPO and how they compare to an isometric cycling specific task. The aim of this study was to establish relationships between maximal voluntary torque production from isometric single-joint and cycling specific tasks and assess their ability to predict PPO. Twenty male trained cyclists participated in this study. Peak torque was measured by performing maximum voluntary contractions (MVC) of knee extensors, knee flexors, dorsi flexors and hip extensors whilst instrumented cranks measured isometric peak torque from MVC when participants were in their cycling specific position (ISOCYC). A stepwise regression showed that peak torque of the knee extensors was the only significant predictor of PPO when using SJD and accounted for 47% of the variance. However, when compared to ISOCYC, the only significant predictor of PPO was ISOCYC, which accounted for 77% of the variance. This suggests that peak torque of the knee extensors was the best single-joint predictor of PPO in sprint cycling. Furthermore, a stronger prediction can be made from a task specific isometric task. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Survival after out-of-hospital cardiac arrest in relation to sex

    DEFF Research Database (Denmark)

    Wissenberg, Mads; Hansen, Carolina Malta; Folke, Fredrik

    2014-01-01

    ); and in females (4.8% in 2001 to 6.7% in 2010), psexes in patients with a non-shockable rhythm (OR 1.00; CI 0.72-1.40), while female sex was positively associated...... characteristics in females with a lower proportion of shockable rhythm. In an adjusted model, female sex was positively associated with survival in patients with a shockable rhythm.......AIM: Crude survival has increased following an out-of-hospital cardiac arrest (OHCA). We aimed to study sex-related differences in patient characteristics and survival during a 10-year study period. METHODS: Patients≥12 years old with OHCA of a presumed cardiac cause, and in whom resuscitation...

  20. Prognostic value of relative adrenal insufficiency after out-of-hospital cardiac arrest.

    Science.gov (United States)

    Pene, Frédéric; Hyvernat, Hervé; Mallet, Vincent; Cariou, Alain; Carli, Pierre; Spaulding, Christian; Dugue, Marie-Annick; Mira, Jean-Paul

    2005-05-01

    To assess the prevalence of relative adrenal insufficiency in patients successfully resuscitated after cardiac arrest, and its prognostic role in post-resuscitation disease. A prospective observational single-center study in a medical intensive care unit. 64 patients hospitalised in the intensive care unit after successful resuscitation for out-of-hospital cardiac arrest. A corticotropin-stimulation test was performed between 12 and 24 h following admission: serum cortisol level was measured before and 60 min after administration of tetracosactide 250 microg. Patients with an incremental response less than 9 microg/dl were considered to have relative adrenal insufficiency (non-responders). Variables were expressed as medians and interquartile ranges. 33 patients (52%) had relative adrenal insufficiency. Baseline cortisol level was higher in non-responders than in responders (41 [27.2-55.5] vs. 22.8 [15.7-35.1] microg/dl respectively, P=0.001). A long interval before initiation of cardiopulmonary resuscitation was associated with relative adrenal insufficiency (5 [3-10] vs. 3 [3-5] min, P=0.03). Of the 38 patients with post-resuscitation shock, 13 died of irreversible multiorgan failure. The presence of relative adrenal insufficiency was identified as a poor prognostic factor of shock-related mortality (log-rank P=0.02). A trend towards higher mortality in non-responders was identified in a multivariate logistic regression analysis (odds ratio 6.77, CI 95% 0.94-48.99, P=0.058). Relative adrenal insufficiency occurs frequently after successful resuscitation of out-of-hospital cardiac arrest, and appears to be associated with a poor prognosis in cases of post-resuscitation shock. The role of corticosteroid supplementation should be evaluated in this setting.

  1. Are Cardiac Autonomic Nervous System Activity and Perceived Stress Related to Functional Somatic Symptoms in Adolescents? The TRAILS Study

    NARCIS (Netherlands)

    Janssens, Karin A. M.; Riese, Harriette; Van Roon, Arie M.; Hunfeld, Joke A. M.; Groot, Paul F. C.; Oldehinkel, Albertine J.; Rosmalen, Judith G. M.

    2016-01-01

    Objective Stressors have been related to medically insufficiently explained or functional somatic symptoms (FSS). However, the underlying mechanism of this association is largely unclear. In the current study, we examined whether FSS are associated with different perceived stress and cardiac

  2. Transient Global Amnesia following Neural and Cardiac Angiography May Be Related to Ischemia

    Directory of Open Access Journals (Sweden)

    Hongzhou Duan

    2016-01-01

    Full Text Available Introduction. Transient global amnesia (TGA following angiography is rare, and the pathogenesis has not been illustrated clearly till now. The aim of this research is to explore the pathogenesis of TGA following angiography by analyzing our data and reviewing the literature. Methods. We retrospectively studied 20836 cases with angiography in our hospital between 2007 and 2015 and found 9 cases with TGA following angiography. The data of these 9 cases were analyzed. Results. We found all 9 cases with TGA following neural angiography (5 in 4360 or cardiac angiography (4 in 8817 and no case with TGA following peripheral angiography (0 in 7659. Statistical difference was found when comparing the neural and cardiac angiography group with peripheral group (p=0.022. Two cases with TGA were confirmed with small acute infarctions in hippocampus after angiography. This might be related to the microemboli which were rushed into vertebral artery following blood flow during neural angiography or cardiac angiography. There was no statistical difference when comparing the different approaches for angiography (p=0.82 and different contrast agents (p=0.619. Conclusion. Based on the positive findings of imaging study and our analysis, we speculate that ischemia in the medial temporal lobe with the involvement of the hippocampus might be an important reason of TGA following angiography.

  3. Pulmonary function and health-related quality of life 1-year follow up after cardiac surgery.

    Science.gov (United States)

    Westerdahl, Elisabeth; Jonsson, Marcus; Emtner, Margareta

    2016-07-08

    Pulmonary function is severely reduced in the early period after cardiac surgery, and impairments have been described up to 4-6 months after surgery. Evaluation of pulmonary function in a longer perspective is lacking. In this prospective study pulmonary function and health-related quality of life were investigated 1 year after cardiac surgery. Pulmonary function measurements, health-related quality of life (SF-36), dyspnoea, subjective breathing and coughing ability and pain were evaluated before and 1 year after surgery in 150 patients undergoing coronary artery bypass grafting, valve surgery or combined surgery. One year after surgery the forced vital capacity and forced expiratory volume in 1 s were significantly decreased (by 4-5 %) compared to preoperative values (p < 0.05). Saturation of peripheral oxygen was unchanged 1 year postoperatively compared to baseline. A significantly improved health-related quality of life was found 1 year after surgery, with improvements in all eight aspects of SF-36 (p < 0.001). Sternotomy-related pain was low 1 year postoperatively at rest (median 0 [min-max; 0-7]), while taking a deep breath (0 [0-4]) and while coughing (0 [0-8]). A more pronounced decrease in pulmonary function was associated with dyspnoea limitations and impaired subjective breathing and coughing ability. One year after cardiac surgery static and dynamic lung function measurements were slightly decreased, while health-related quality of life was improved in comparison to preoperative values. Measured levels of pain were low and saturation of peripheral oxygen was same as preoperatively.

  4. Early diagnosis of myocardial infarction using absolute and relative changes in cardiac troponin concentrations.

    Science.gov (United States)

    Irfan, Affan; Reichlin, Tobias; Twerenbold, Raphael; Meister, Marc; Moehring, Berit; Wildi, Karin; Bassetti, Stefano; Zellweger, Christa; Gimenez, Maria Rubini; Hoeller, Rebeca; Murray, Karsten; Sou, Seoung Mann; Mueller, Mira; Mosimann, Tamina; Reiter, Miriam; Haaf, Philip; Ziller, Ronny; Freidank, Heike; Osswald, Stefan; Mueller, Christian

    2013-09-01

    Absolute changes in high-sensitivity cardiac troponin T (hs-cTnT) seem to have higher diagnostic accuracy in the early diagnosis of acute myocardial infarction compared with relative changes. It is unknown whether the same applies to high-sensitivity cardiac troponin I (hs-cTnI) assays and whether the combination of absolute and relative change might further increase accuracy. In a prospective, international multicenter study, high-sensitivity cardiac troponin (hs-cTn) was measured with 3 novel assays (hs-cTnT, Roche Diagnostics Corp, Indianapolis, Ind; hs-cTnI, Beckman Coulter Inc, Brea, Calif; hs-cTnI, Siemens, Munich, Germany) in a blinded fashion at presentation and after 1 and 2 hours in a blinded fashion in 830 unselected patients with suspected acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. The area under the receiver operating characteristic curve for diagnosing acute myocardial infarction was significantly higher for 1- and 2-hour absolute versus relative hs-cTn changes for all 3 assays (P Siemens, 0.96 [95% CI, 0.93-0.99]) were high and provided some benefit compared with the use of absolute change alone for hs-cTnT, but not for the hs-cTnI assays. Reclassification analysis confirmed the superiority of absolute changes versus relative changes. Absolute changes seem to be the preferred metrics for both hs-cTnT and hs-cTnI in the early diagnosis of acute myocardial infarction. The combination of absolute and relative changes provides a small added value for hs-cTnT, but not for hs-cTnI. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Input/output manual of light water reactor fuel performance code FEMAXI-7 and its related codes

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Motoe; Udagawa, Yutaka; Nagase, Fumihisa [Japan Atomic Energy Agency, Nuclear Safety Research Center, Tokai, Ibaraki (Japan); Saitou, Hiroaki [ITOCHU Techno-Solutions Corp., Tokyo (Japan)

    2012-07-15

    A light water reactor fuel analysis code FEMAXI-7 has been developed for the purpose of analyzing the fuel behavior in normal conditions and in anticipated transient conditions. Numerous functional improvements and extensions have been incorporated in FEMAXI-7, which has been fully disclosed in the code model description published recently as JAEA-Data/Code 2010-035. The present manual, which is the counterpart of this description, gives detailed explanations of operation method of FEMAXI-7 code and its related codes, methods of Input/Output, methods of source code modification, features of subroutine modules, and internal variables in a specific manner in order to facilitate users to perform a fuel analysis with FEMAXI-7. This report includes some descriptions which are modified from the original contents of JAEA-Data/Code 2010-035. A CD-ROM is attached as an appendix. (author)

  6. Input/output manual of light water reactor fuel performance code FEMAXI-7 and its related codes

    International Nuclear Information System (INIS)

    Suzuki, Motoe; Udagawa, Yutaka; Nagase, Fumihisa; Saitou, Hiroaki

    2012-07-01

    A light water reactor fuel analysis code FEMAXI-7 has been developed for the purpose of analyzing the fuel behavior in normal conditions and in anticipated transient conditions. Numerous functional improvements and extensions have been incorporated in FEMAXI-7, which has been fully disclosed in the code model description published recently as JAEA-Data/Code 2010-035. The present manual, which is the counterpart of this description, gives detailed explanations of operation method of FEMAXI-7 code and its related codes, methods of Input/Output, methods of source code modification, features of subroutine modules, and internal variables in a specific manner in order to facilitate users to perform a fuel analysis with FEMAXI-7. This report includes some descriptions which are modified from the original contents of JAEA-Data/Code 2010-035. A CD-ROM is attached as an appendix. (author)

  7. Age-Related Interference between the Selection of Input-Output Modality Mappings and Postural Control—a Pilot Study

    Science.gov (United States)

    Stelzel, Christine; Schauenburg, Gesche; Rapp, Michael A.; Heinzel, Stephan; Granacher, Urs

    2017-01-01

    Age-related decline in executive functions and postural control due to degenerative processes in the central nervous system have been related to increased fall-risk in old age. Many studies have shown cognitive-postural dual-task interference in old adults, but research on the role of specific executive functions in this context has just begun. In this study, we addressed the question whether postural control is impaired depending on the coordination of concurrent response-selection processes related to the compatibility of input and output modality mappings as compared to impairments related to working-memory load in the comparison of cognitive dual and single tasks. Specifically, we measured total center of pressure (CoP) displacements in healthy female participants aged 19–30 and 66–84 years while they performed different versions of a spatial one-back working memory task during semi-tandem stance on an unstable surface (i.e., balance pad) while standing on a force plate. The specific working-memory tasks comprised: (i) modality compatible single tasks (i.e., visual-manual or auditory-vocal tasks), (ii) modality compatible dual tasks (i.e., visual-manual and auditory-vocal tasks), (iii) modality incompatible single tasks (i.e., visual-vocal or auditory-manual tasks), and (iv) modality incompatible dual tasks (i.e., visual-vocal and auditory-manual tasks). In addition, participants performed the same tasks while sitting. As expected from previous research, old adults showed generally impaired performance under high working-memory load (i.e., dual vs. single one-back task). In addition, modality compatibility affected one-back performance in dual-task but not in single-task conditions with strikingly pronounced impairments in old adults. Notably, the modality incompatible dual task also resulted in a selective increase in total CoP displacements compared to the modality compatible dual task in the old but not in the young participants. These results suggest

  8. Ventilation and cardiac related impedance changes in children undergoing corrective open heart surgery

    International Nuclear Information System (INIS)

    Schibler, Andreas; Pham, Trang M T; Moray, Amol A; Stocker, Christian

    2013-01-01

    Electrical impedance tomography (EIT) can determine ventilation and perfusion relationship. Most of the data obtained so far originates from experimental settings and in healthy subjects. The aim of this study was to demonstrate that EIT measures the perioperative changes in pulmonary blood flow after repair of a ventricular septum defect in children with haemodynamic relevant septal defects undergoing open heart surgery. In a 19 bed intensive care unit in a tertiary children's hospital ventilation and cardiac related impedance changes were measured using EIT before and after surgery in 18 spontaneously breathing patients. The EIT signals were either filtered for ventilation (ΔZV) or for cardiac (ΔZQ) related impedance changes. Impedance signals were then normalized (normΔZV, normΔZQ) for calculation of the global and regional impedance related ventilation perfusion relationship (normΔZV/normΔZQ). We observed a trend towards increased normΔZV in all lung regions, a significantly decreased normΔZQ in the global and anterior, but not the posterior lung region. The normΔZV/normΔZQ was significantly increased in the global and anterior lung region. Our study qualitatively validates our previously published modified EIT filtration technique in the clinical setting of young children with significant left-to-right shunt undergoing corrective open heart surgery, where perioperative assessment of the ventilation perfusion relation is of high clinical relevance. (paper)

  9. Ventilation and cardiac related impedance changes in children undergoing corrective open heart surgery.

    Science.gov (United States)

    Schibler, Andreas; Pham, Trang M T; Moray, Amol A; Stocker, Christian

    2013-10-01

    Electrical impedance tomography (EIT) can determine ventilation and perfusion relationship. Most of the data obtained so far originates from experimental settings and in healthy subjects. The aim of this study was to demonstrate that EIT measures the perioperative changes in pulmonary blood flow after repair of a ventricular septum defect in children with haemodynamic relevant septal defects undergoing open heart surgery. In a 19 bed intensive care unit in a tertiary children's hospital ventilation and cardiac related impedance changes were measured using EIT before and after surgery in 18 spontaneously breathing patients. The EIT signals were either filtered for ventilation (ΔZV) or for cardiac (ΔZQ) related impedance changes. Impedance signals were then normalized (normΔZV, normΔZQ) for calculation of the global and regional impedance related ventilation perfusion relationship (normΔZV/normΔZQ). We observed a trend towards increased normΔZV in all lung regions, a significantly decreased normΔZQ in the global and anterior, but not the posterior lung region. The normΔZV/normΔZQ was significantly increased in the global and anterior lung region. Our study qualitatively validates our previously published modified EIT filtration technique in the clinical setting of young children with significant left-to-right shunt undergoing corrective open heart surgery, where perioperative assessment of the ventilation perfusion relation is of high clinical relevance.

  10. Effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation

    Directory of Open Access Journals (Sweden)

    Xing-Tao Cai

    2016-01-01

    Full Text Available Objective: To study the effect of fast-track cardiac anesthesia on myocardial oxidative damage, inflammation and nerve related peptides of patients undergoing cardiac operation. Methods: Sixty patients with rheumatic heart disease undergoing heart valve surgery were randomly divided into the fast track group (n=30 and conventional group (n=30. Then myocardial injury indicators, mitochondrial oxidative stress indicators, inflammation indicators and nerverelated peptides of both groups were analyzed. Results: cTnI contents at T2-T4 points in time of both groups showed an increasing trend and the increasing trend of fast track group was weaker than that of conventional group; SOD contents as well as mitochondrial tristate respiratory function, respiratory control ratios and phosphorus oxygen ratios in myocardial tissue of fast track group were higher than those of conventional group, and MDA contents was lower than those of conventional group; plasma TNF-α, IL-6, IL-8, NSE, S100β and Aβ contents of fast track group were lower than those of conventional group. Conclusions: Fasttrack cardiac anesthesia can protect myocardial cells, reduce mitochondrial oxidative stress, relieve inflammation and improve nerve function; it is an ideal anesthesia method for cardiac operation.

  11. Plasma glutamine levels before cardiac surgery are related to post-surgery infections; an observational study

    Directory of Open Access Journals (Sweden)

    Hanneke Buter

    2016-11-01

    Full Text Available Abstract Background A low plasma glutamine level was found in 34% of patients after elective cardiothoracic surgery. This could be a result of the inflammation caused by surgical stress or the use of extracorporeal circulation (ECC. But it is also possible that plasma glutamine levels were already lowered before surgery and reflect an impaired metabolic state and a higher likelihood to develop complications. In the present study plasma glutamine levels were measured before and after cardiac surgery and we questioned whether there is a relation between plasma glutamine levels and duration of ECC and the occurrence of postoperative infections. Methods We performed a single-centre prospective, observational study in a closed-format, 20-bed, mixed ICU in a tertiary teaching hospital. We included consecutive patients after elective cardiac surgery with use of extracorporeal circulation. Blood samples were collected on the day prior to surgery and at admission on the ICU. The study was approved by the local Medical Ethics Committee (Regional Review Committee Patient-related Research, Medical Centre Leeuwarden, nWMO 115, April 28th 2015. Results Ninety patients were included. Pre-operative plasma glutamine level was 0.42 ± 0.10 mmol/l and post-operative 0.38 ± 0.09 mmol/l (p < 0.001. There was no relation between duration of extracorporeal circulation or aortic occlusion time and changes in plasma glutamine levels. A logistic regression analysis showed a significant correlation between the presence of a positive culture during the post-operative course and pre-operative plasma glutamine levels (p = 0.04. Conclusion Plasma glutamine levels are significantly lower just after cardiac surgery compared to pre-operative levels. We did not find a relation between the decrease in plasma glutamine levels and the duration of extracorporeal circulation or aortic clamp time. There was a correlation between pre-operative plasma glutamine levels

  12. Cardiac gated ventilation

    International Nuclear Information System (INIS)

    Hanson, C.W. III; Hoffman, E.A.

    1995-01-01

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. The authors evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50 msec scan aperture. Multi slice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. The authors observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a non-failing model of the heart

  13. Job satisfaction and work related variables in Chinese cardiac critical care nurses.

    Science.gov (United States)

    Liu, Yun-E; While, Alison; Li, Shu-Jun; Ye, Wen-Qin

    2015-05-01

    To explore critical care nurses' views of their job satisfaction and the relationship with job burnout, practice environment, coping style, social support, intention to stay in current employment and other work-related variables. Nurse shortage is a global issue, especially in critical care. Job satisfaction is the most frequently cited factor linked to nurses' turnover. A convenience sample of cardiac critical care nurses (n = 215; 97.7% response rate) from 12 large general hospitals in Shanghai was surveyed from December 2010 to March 2011. Over half of the sample reported satisfaction with their jobs. Nurses with 10-20 years of professional experience and those who had taken all their holiday entitlement reported higher levels of job satisfaction. The independent variables of practice environment, intention to stay, emotional exhaustion, personal accomplishment and positive coping style explained about 55% of the variance in job satisfaction. Chinese cardiac critical care nurses' job satisfaction was related to work related variables, which are amenable to managerial action. Our findings highlight the imperative of improving intrinsic and extrinsic rewards, together with the flexibility of work schedules to promote job satisfaction and staff retention. A clinical ladder system is needed to provide promotion opportunities for Chinese nurses. © 2013 John Wiley & Sons Ltd.

  14. Family-based cardiac screening in relatives of victims of sudden arrhythmic death syndrome.

    LENUS (Irish Health Repository)

    McGorrian, Catherine

    2013-02-03

    AIMS: Sudden arrhythmic death syndrome (SADS) occurs when a person suffers a sudden, unexpected death, with no cause found at postmortem examination. We aimed to describe the cardiac screening outcomes in a population of relatives of SADS victimsMETHODS AND RESULTS: Prospective and retrospective cohort study of consecutive families attending the Family Heart Screening clinic at the Mater Misericordiae Hospital in Dublin, Ireland, from January 2007 to September 2011. Family members of SADS victims underwent a standard screening protocol. Adjunct clinical and postmortem information was sought on the proband. Families who had an existing diagnosis, or where the proband had epilepsy, were excluded. Of 115 families identified, 73 were found to fit inclusion criteria and were retained for analysis, with data available on 262 relatives. Over half of the screened family members were female, and the mean age was 38.6 years (standard deviation 15.6). In 22 of 73 families (30%), and 36 of 262 family members (13.7%), a potentially inheritable cause of SADS was detected. Of the population screened, 32 patients (12.2%) were treated with medication, and 5 (1.9%) have received implantable cardiac defibrillators. Of the five families with long QT syndrome (LQTS) who had a pathogenic gene mutation identified, three carried two such mutations.CONCLUSION: In keeping with international estimates, 30% of families of SADS victims were found to have a potentially inherited cardiac disease. The most common positive finding was LQTS. Advances in postmortem standards and genetic studies may assist in achieving more diagnoses in these families.

  15. Views on equine-related research in Australia from the Australian equestrian community: perceived outputs and benefits.

    Science.gov (United States)

    Thompson, K; Clarkson, L

    2016-04-01

    The extension of research into public practice is enhanced by communication and behaviour change strategies that are consistent with consumer needs and perspectives. To gain support for equine research (or to appreciate the perspectives contributing to disagreement), it is necessary to determine how aware consumers are of research, what research means to them, how they perceive its benefits (if at all) and how they engage with (or resist) it. Because of a surprising dearth of research evaluating consumer perceptions of research in any sector, our aim was to identify the perceived outputs and benefits of research from the perspective of the Australian horse owner. We analysed the data for 930 participants in an online survey. Participants' understanding of research was associated with a broad terminology. Slightly more than half were aware of equine research that had taken place in Australia, with almost half reporting gaining some benefit, notably in relation to equine health. Although comments demonstrated an awareness of the collective benefit of research, research was made meaningful in relation to local conditions and participants' own equestrian disciplines. There is a significant opportunity for increasing awareness of Australia-based equine research and its value to owners of horses. The critical engagement with research by some owners suggests the need for communicators to present research in terms suitable for an intelligent lay audience, with clear identification of the personal and collective benefits for owners, horses and the equestrian community. © 2016 Australian Veterinary Association.

  16. An experimental extrapolation technique using the Gafchromic EBT3 film for relative output factor measurements in small x-ray fields

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Johnny E., E-mail: johnny.morales@lh.org.au [Department of Radiation Oncology, Chris O’Brien Lifehouse, 119-143 Missenden Road, Camperdown, NSW 2050, Australia and School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Level 4 O Block, Garden’s Point, QLD 4001 (Australia); Butson, Martin; Hill, Robin [Department of Radiation Oncology, Chris O’Brien Lifehouse, 119-143 Missenden Road, Camperdown, NSW 2050, Australia and Institute of Medical Physics, University of Sydney, NSW 2006 (Australia); Crowe, Scott B. [School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Level 4 O Block, Garden’s Point, QLD 4001, Australia and Cancer Care Services, Royal Brisbane and Women’s Hospital, Butterfield Street, Herston, QLD 4029 (Australia); Trapp, J. V. [School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Level 4 O Block, Garden’s Point, QLD 4001 (Australia)

    2016-08-15

    Purpose: An experimental extrapolation technique is presented, which can be used to determine the relative output factors for very small x-ray fields using the Gafchromic EBT3 film. Methods: Relative output factors were measured for the Brainlab SRS cones ranging in diameters from 4 to 30 mm{sup 2} on a Novalis Trilogy linear accelerator with 6 MV SRS x-rays. The relative output factor was determined from an experimental reducing circular region of interest (ROI) extrapolation technique developed to remove the effects of volume averaging. This was achieved by scanning the EBT3 film measurements with a high scanning resolution of 1200 dpi. From the high resolution scans, the size of the circular regions of interest was varied to produce a plot of relative output factors versus area of analysis. The plot was then extrapolated to zero to determine the relative output factor corresponding to zero volume. Results: Results have shown that for a 4 mm field size, the extrapolated relative output factor was measured as a value of 0.651 ± 0.018 as compared to 0.639 ± 0.019 and 0.633 ± 0.021 for 0.5 and 1.0 mm diameter of analysis values, respectively. This showed a change in the relative output factors of 1.8% and 2.8% at these comparative regions of interest sizes. In comparison, the 25 mm cone had negligible differences in the measured output factor between zero extrapolation, 0.5 and 1.0 mm diameter ROIs, respectively. Conclusions: This work shows that for very small fields such as 4.0 mm cone sizes, a measureable difference can be seen in the relative output factor based on the circular ROI and the size of the area of analysis using radiochromic film dosimetry. The authors recommend to scan the Gafchromic EBT3 film at a resolution of 1200 dpi for cone sizes less than 7.5 mm and to utilize an extrapolation technique for the output factor measurements of very small field dosimetry.

  17. Effect of overreaching on cognitive performance and related cardiac autonomic control.

    Science.gov (United States)

    Dupuy, O; Lussier, M; Fraser, S; Bherer, L; Audiffren, M; Bosquet, L

    2014-02-01

    The purpose of this study was to characterize the effect of a 2-week overload period immediately followed by a 1-week taper period on different cognitive processes including executive and nonexecutive functions, and related heart rate variability. Eleven male endurance athletes increased their usual training volume by 100% for 2 weeks, and decreased it by 50% for 1 week. A maximal graded test, a constant speed test at 85% of peak treadmill speed, and a Stroop task with the measurement of heart rate variability were performed at each period. All participants were considered as overreached. We found a moderate increase in the overall reaction time to the three conditions of the Stroop task after the overload period (816 ± 83 vs 892 ± 117 ms, P = 0.03) followed by a return to baseline after the taper period (820 ± 119 ms, P = 0.013). We found no association between cognitive performance and cardiac parasympathetic control at baseline, and no association between changes in these measures. Our findings clearly underscore the relevance of cognitive performance in the monitoring of overreaching in endurance athletes. However, contrary to our hypothesis, we did not find any relationship between executive performance and cardiac parasympathetic control. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Evaluation and optimisation of current milrinone prescribing for the treatment and prevention of low cardiac output syndrome in paediatric patients after open heart surgery using a physiology-based pharmacokinetic drug-disease model.

    Science.gov (United States)

    Vogt, Winnie

    2014-01-01

    Milrinone is the drug of choice for the treatment and prevention of low cardiac output syndrome (LCOS) in paediatric patients after open heart surgery across Europe. Discrepancies, however, among prescribing guidance, clinical studies and practice pattern require clarification to ensure safe and effective prescribing. However, the clearance prediction equations derived from classical pharmacokinetic modelling provide limited support as they have recently failed a clinical practice evaluation. Therefore, the objective of this study was to evaluate current milrinone dosing using physiology-based pharmacokinetic (PBPK) modelling and simulation to complement the existing pharmacokinetic knowledge and propose optimised dosing regimens as a basis for improving the standard of care for paediatric patients. A PBPK drug-disease model using a population approach was developed in three steps from healthy young adults to adult patients and paediatric patients with and without LCOS after open heart surgery. Pre- and postoperative organ function values from adult and paediatric patients were collected from literature and integrated into a disease model as factorial changes from the reference values in healthy adults aged 20-40 years. The disease model was combined with the PBPK drug model and evaluated against existing pharmacokinetic data. Model robustness was assessed by parametric sensitivity analysis. In the next step, virtual patient populations were created, each with 1,000 subjects reflecting the average adult and paediatric patient characteristics with regard to age, sex, bodyweight and height. They were integrated into the PBPK drug-disease model to evaluate the effectiveness of current milrinone dosing in achieving the therapeutic target range of 100-300 ng/mL milrinone in plasma. Optimised dosing regimens were subsequently developed. The pharmacokinetics of milrinone in healthy young adults as well as adult and paediatric patients were accurately described with an

  19. Relationship between cardiac function and resting cerebral blood flow: MRI measurements in healthy elderly subjects.

    Science.gov (United States)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja; Larsson, Henrik B W; Rostrup, Egill

    2014-11-01

    Although both impaired cardiac function and reduced cerebral blood flow are associated with ageing, current knowledge of the influence of cardiac function on resting cerebral blood flow (CBF) is limited. The aim of this study was to investigate the potential effects of cardiac function on CBF. CBF and cardiac output were measured in 31 healthy subjects 50-75 years old using magnetic resonance imaging techniques. Mean values of CBF, cardiac output and cardiac index were 43.6 ml per 100 g min(-1), 5.5 l min(-1) and 2.7 l min(-1) m(-2), respectively, in males, and 53.4 ml per 100 g min(-1), 4.3 l min(-1) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P = 0.008) and furthermore lower in males than in females (8.6% versus 12.5%, P = 0.003). Fractional brain flow was also inversely correlated with cerebral white matter lesion grade, although this effect was not significant when adjusted for age. Frequency analysis of heart rate variability showed a gender-related inverse association of increased low-to-high-frequency power ratio with CBF and fractional brain flow. The findings do not support a direct effect of cardiac function on CBF, but demonstrates gender-related differences in cardiac output distribution. We propose fractional brain flow as a novel index that may be a useful marker of adequate brain perfusion in the context of ageing as well as cardiovascular disease. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  20. Cardiac autonomic neuropathy in patients with uraemia is not related to pre-diabetes

    DEFF Research Database (Denmark)

    Eming, Marie Bayer; Hornum, Mads; Feldt-Rasmussen, Bo Friis

    2011-01-01

    INTRODUCTION: It has been proposed that pre-diabetes may cause neuropathy. The aim of this study was to investigate whether cardiac autonomic neuropathy (CAN) in uraemic patients was related to the presence of pre-diabetes. MATERIAL AND METHODS: The study included 66 non-diabetic uraemic patients...... enrolled. Beat-to-beat variability was determined from the echocardiographic (ECG) recording during deep inspiration and expiration. CAN was defined as a beat-to-beat value below 10 beats/min. Pre-diabetes was defined as presence of impaired fasting glucose and/or impaired glucose tolerance measured...... by oral glucose tolerance test (WHO/American Diabetes Association criteria 2007). RESULTS: The prevalence of CAN was 38% in uraemic patients compared with 8% in the controls (p prediabetic, while the remaining 39 had a normal glucose...

  1. Impaired left ventricular systolic function reserve limits cardiac output and exercise capacity in HFpEF patients due to systemic hypertension.

    Science.gov (United States)

    Henein, Michael; Mörner, Stellan; Lindmark, Krister; Lindqvist, Per

    2013-09-30

    Heart failure (HF) patients with preserved left ventricular (LV) ejection fraction (EF) (HFpEF) due to systemic hypertension (SHT) are known to have limited exercise tolerance. Despite having normal EF at rest, we hypothesize that these patients have abnormal systolic function reserve limiting their exercise capacity. Seventeen patients with SHT (mean age 68 ± 9 years) but no valve disease and 14 healthy individuals (mean age of 65 ± 10 years) underwent resting and peak exercise echocardiography using conventional, tissue Doppler and speckle tracking techniques. The differences between resting and peak exercise values were also analyzed (Δ). Exercise capacity was determined as the workload divided by body surface area. Resting values for left atrial (LA) volume/BSA (r=-0.66, pexercise capacity. LVEF increased during exercise in normals (mean Δ EF=10 ± 8%) but failed to do so in patients (mean Δ EF=0.6 ± 9%, pexercise in patients, to the same extent as it did in normals (0.2 ± 0.2 vs. 0.6 ± 0.3 1/s, pexercise (Δ) in LV lateral wall systolic velocity from tissue Doppler (s') (0.71, pexercise capacity independent of changes in heart rate. HFpEF patients with hypertensive LV disease have significantly limited exercise capacity which is related to left atrial enlargement as well as compromised LV systolic function at the time of the symptoms. The limited myocardial systolic function reserve seems to be underlying important explanation for their limited exercise capacity. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  3. Odour identification test and its relation to cardiac 123I‐metaiodobenzylguanidine in patients with drug induced parkinsonism

    Science.gov (United States)

    Lee, Phil Hyu; Yeo, Seung Hyeon; Yong, Seok Woo; Kim, Yun Joong

    2007-01-01

    We investigated olfactory function and its relation to cardiac 123I‐metaiodobenzylguanidine (MIBG) uptake in 15 patients with drug induced parkinsonism (DIP). The mean Cross Cultural Smell Identification (CCSI) score was significantly greater in patients with DIP than in those with Parkinson's disease (PD: 6.9 (1.6) vs 4.4 (2.2); p<0.001); however, the mean CCSI score in patients with DIP was not significantly different from controls. One patient with DIP, whose CCSI score was significantly reduced, also exhibited decreased cardiac MIBG uptake. DIP patients with CCSI scores within the normal range had normal cardiac MIBG uptake. Our study suggests that an olfactory function test may be a useful tool for detecting DIP unrelated to PD and for identifying patients with DIP who have subclinical PD. PMID:17557797

  4. Are Cardiac Autonomic Nervous System Activity and Perceived Stress Related to Functional Somatic Symptoms in Adolescents? The TRAILS Study

    NARCIS (Netherlands)

    Janssens, Karin A. M.; Riese, Harriëtte; van Roon, Arie M.; Hunfeld, Joke A. M.; Groot, Paul F. C.; Oldehinkel, Albertine J.; Rosmalen, Judith G. M.

    2016-01-01

    Stressors have been related to medically insufficiently explained or functional somatic symptoms (FSS). However, the underlying mechanism of this association is largely unclear. In the current study, we examined whether FSS are associated with different perceived stress and cardiac autonomic nervous

  5. Sports-related sudden cardiac death in a competitive and a noncompetitive athlete population aged 12 to 49 years

    DEFF Research Database (Denmark)

    Risgaard, Bjarke; Winkel, Bo Gregers; Jabbari, Reza

    2014-01-01

    BACKGROUND: Preparticipation screening programs have been suggested to reduce the numbers of sports-related sudden cardiac deaths (SrSCD). OBJECTIVE: The purpose of this study was to identify and characterize all SrSCD aged 12-49 years and to address the difference in incidence rates between...

  6. Are Cardiac Autonomic Nervous System Activity and Perceived Stress Related to Functional Somatic Symptoms in Adolescents? The TRAILS Study.

    Directory of Open Access Journals (Sweden)

    Karin A M Janssens

    Full Text Available Stressors have been related to medically insufficiently explained or functional somatic symptoms (FSS. However, the underlying mechanism of this association is largely unclear. In the current study, we examined whether FSS are associated with different perceived stress and cardiac autonomic nervous system (ANS levels during a standardized stressful situation, and whether these associations are symptom-specific.We examined 715 adolescents (16.1 years, 51.3% girls from the Dutch cohort study Tracking Adolescents' Individual Lives Sample during the Groningen Social Stress Test (GSST. FSS were assessed by the Youth Self-Report, and clustered into a cluster of overtiredness, dizziness and musculoskeletal pain and a cluster of headache and gastrointestinal symptoms. Perceived stress levels (i.e. unpleasantness and arousal were assessed by the Self-Assessment Manikin, and cardiac ANS activity by assessing heart rate variability (HRV-HF and pre-ejection period (PEP. Perceived stress and cardiac ANS levels before, during, and after the GSST were studied as well as cardiac ANS reactivity. Linear regression analyses were used to examine the associations.Perceived arousal levels during (beta = 0.09, p = 0.04 and after (beta = 0.07, p = 0.047 the GSST, and perceived unpleasantness levels before (beta = 0.07, p = 0.048 and during (beta = 0.12, p = 0.001 the GSST were related to FSS during the past couple of months. The association between perceived stress and FSS was stronger for the FSS cluster of overtiredness, dizziness and musculoskeletal pain than for the cluster of headache and gastrointestinal symptoms. Neither ANS activity levels before, during, and after the GSST, nor maximal HF-HRV and PEP reactivity were related to FSS.This study suggests that perceived stress levels during social stress are related to FSS, whereas cardiac ANS activity and reactivity are not related to FSS.

  7. Relations between Cardiac and Visual Phenotypes in Diabetes: A Multivariate Approach.

    Science.gov (United States)

    Oliveiros, Bárbara; Sanches, Mafalda; Quendera, Bruno; Graça, Bruno; Guelho, Daniela; Gomes, Leonor; Carrilho, Francisco; Caseiro-Alves, Filipe; Castelo-Branco, Miguel

    2016-01-01

    relation between cardiac and retinal diabetic phenotypes.

  8. A different management of saphenous vein graft failure related to cardiac tamponade following coronary surgery

    Directory of Open Access Journals (Sweden)

    Hamit Serdar Başbuğ

    2016-03-01

    Full Text Available Cardiac tamponade is a state of constriction of the heart with an excessive fluid or hematoma resulted from various conditions. Postoperative tamponade can occur after coronary bypass surgery. Despite it is uncommon, its results may have a high risk of mortality and morbidity. Acute postoperative cardiac tamponade reveals a vast spectrum of symptoms. Moreover, a compression over the saphenous vein graft is the worst complication that should be managed without delay. We report a rare case of saphenous vein graft failure due to the cardiac tamponade following a coronary surgery and its management with a practical measure.

  9. Is Ward Experience in Resuscitation Effort Related to the Prognosis of Unexpected Cardiac Arrest?

    Directory of Open Access Journals (Sweden)

    Sen-Kuang Hou

    2007-09-01

    Conclusion: Hospital wards with more than 5 cardiac arrests per year have a better patient survival rate than those with fewer arrests. This is despite all ward staff receiving the same level of training.

  10. Markers of Intestinal Damage and their Relation to Cytokine Levels in Cardiac Surgery Patients

    NARCIS (Netherlands)

    Habes, Q.L.M.; Linssen, V.; Nooijen, S.; Kiers, D.; Gerretsen, J.; Pickkers, P.; Scheffer, G.J.; Kox, M.

    2017-01-01

    OBJECTIVES: In patients undergoing cardiac surgery, both extracorporeal circulation (ECC) and intraoperative mesenterial hypoperfusion may account for increased cytokine levels and lead to postoperative gastrointestinal (GI) symptoms. METHODS: We investigated levels of the intestinal damage markers

  11. Research on the relativity between gene polymorphism and children cardiac insufficiency.

    Science.gov (United States)

    He, X-H; Li, C-L; Ling, N; Wang, Q-W; Wang, Z-Z; An, X-J

    2017-08-01

    We analyzed the relationship between Mink-S27 gene polymorphism and children with cardiac insufficiency. From April 2013 to April 2015, we enrolled 73 cases of children with cardiac insufficiency for this study, and all 73 were placed in the observation group. 76 normal cases were selected for the control group. Restriction fragment length polymorphism (RFLP) was used to make polymorphism analysis of the Mink-S27. Our results showed no significant differences in Mink-S27 genotype and allele distribution in both observation and control groups (p>0.05). In lesion samples collected from children with cardiac insufficiency, we detected significant difference in AA, CC genotype frequency and allele frequency between the observation group and the control group (prelatively high. GNAS2 gene polymorphism was associated with the prevalence of cardiac insufficiency in children. And also the patients' condition was correlated to the frequency of different genotypes and alleles.

  12. Prediction of drug-related cardiac adverse effects in humans--B: use of QSAR programs for early detection of drug-induced cardiac toxicities.

    Science.gov (United States)

    Frid, Anna A; Matthews, Edwin J

    2010-04-01

    This report describes the use of three quantitative structure-activity relationship (QSAR) programs to predict drug-related cardiac adverse effects (AEs), BioEpisteme, MC4PC, and Leadscope Predictive Data Miner. QSAR models were constructed for 9 cardiac AE clusters affecting Purkinje nerve fibers (arrhythmia, bradycardia, conduction disorder, electrocardiogram, palpitations, QT prolongation, rate rhythm composite, tachycardia, and Torsades de pointes) and 5 clusters affecting the heart muscle (coronary artery disorders, heart failure, myocardial disorders, myocardial infarction, and valve disorders). The models were based on a database of post-marketing AEs linked to 1632 chemical structures, and identical training data sets were configured for three QSAR programs. Model performance was optimized and shown to be affected by the ratio of the number of active to inactive drugs. Results revealed that the three programs were complementary and predictive performances using any single positive, consensus two positives, or consensus three positives were as follows, respectively: 70.7%, 91.7%, and 98.0% specificity; 74.7%, 47.2%, and 21.0% sensitivity; and 138.2, 206.3, and 144.2 chi(2). In addition, a prospective study using AE data from the U.S. Food and Drug Administration's (FDA's) MedWatch Program showed 82.4% specificity and 94.3% sensitivity. Furthermore, an external validation study of 18 drugs with serious cardiotoxicity not considered in the models had 88.9% sensitivity. Published by Elsevier Inc.

  13. Impaired cardiac SIRT1 activity by carbonyl stress contributes to aging-related ischemic intolerance.

    Directory of Open Access Journals (Sweden)

    Chunhu Gu

    Full Text Available Reactive aldehydes can initiate protein oxidative damage which may contribute to heart senescence. Sirtuin 1 (SIRT1 is considered to be a potential interventional target for I/R injury management in the elderly. We hypothesized that aldehyde mediated carbonyl stress increases susceptibility of aged hearts to ischemia/reperfusion (I/R injury, and elucidate the underlying mechanisms with a focus on SIRT1. Male C57BL/6 young (4-6 mo and aged (22-24 mo mice were subjected to myocardial I/R. Cardiac aldehyde dehydrogenase (ALDH2, SIRT1 activity and protein carbonyls were assessed. Our data revealed that aged heart exhibited increased endogenous aldehyde/carbonyl stress due to impaired ALDH2 activity concomitant with blunted SIRT1 activity (P<0.05. Exogenous toxic aldehydes (4-HNE exposure in isolated cardiomyocyte verified that aldehyde-induced carbonyl modification on SIRT1 impaired SIRT1 activity leading to worse hypoxia/reoxygenation (H/R injury, which could all be rescued by Alda-1 (ALDH2 activator (all P<0.05. However, SIRT1 inhibitor blocked the protective effect of Alda-1 on H/R cardiomyocyte. Interestingly, myocardial I/R leads to higher carbonylation but lower activity of SIRT1 in aged hearts than that seen in young hearts (P<0.05. The application of Alda-1 significantly reduced the carbonylation on SIRT1 and markedly improved the tolerance to in vivo I/R injury in aged hearts, but failed to protect Sirt1(+/- knockout mice against myocardial I/R injury. This was verified by Alda-1 treatment improved postischemic contractile function recovery in ex vivo perfused aged but not in Sirt1(+/- hearts. Thus, aldehyde/carbonyl stress is accelerated in aging heart. These results provide a new insight that impaired cardiac SIRT1 activity by carbonyl stress plays a critical role in the increased susceptibility of aged heart to I/R injury. ALDH2 activation can restore this aging-related myocardial ischemic intolerance.

  14. Work-related outcome after acute coronary syndrome: Implications of complex cardiac rehabilitation in occupational medicine.

    Science.gov (United States)

    Lamberti, Monica; Ratti, Gennaro; Gerardi, Donato; Capogrosso, Cristina; Ricciardi, Gianfranco; Fulgione, Cosimo; Latte, Salvatore; Tammaro, Paolo; Covino, Gregorio; Nienhaus, Albert; Grazillo, Elpidio Maria; Mallardo, Mario; Capogrosso, Paolo

    2016-01-01

    Coronary heart disease is frequent in the working-age population. Traditional outcomes, such as mortality and hospital readmission, are useful for evaluating prognosis. Fit-for-work is an emerging outcome with clinical as well as socioeconomic significance. We describe the possible benefit of a cardiac rehabilitation (CR) program for return to work (RTW) after acute coronary syndrome (ACS). We evaluated 204 patients with recent ACS. They were divided into 4 groups on the basis of their occupational work load: very light (VL), light (L), moderate (M), and heavy (H). Work-related outcomes were assessed with the Work Performance Scale (WPS) of the Functional Status Questionnaire and as "days missed from work" (DMW) in the previous 4 weeks. The variables considered for outcomes were percent ejection fraction, functional capacity expressed in metabolic equivalents (METs), and participation or non-participation in the CR program (CR+ and CR-). One hundred thirty (66%) patients took part in the CR program. Total WPS scores for CR+ and CR- subgroups were VL group: 18±4 vs. 14±4 (p workplace, in particular among clerical workers. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  15. Sports-related sudden cardiac deaths in the young population of Switzerland.

    Science.gov (United States)

    Asatryan, Babken; Vital, Cristina; Kellerhals, Christoph; Medeiros-Domingo, Argelia; Gräni, Christoph; Trachsel, Lukas D; Schmied, Christian M; Saguner, Ardan M; Eser, Prisca; Herzig, David; Bolliger, Stephan; Michaud, Katarzyna; Wilhelm, Matthias

    2017-01-01

    In Switzerland, ECG screening was first recommended for national squad athletes in 1998. Since 2001 it has become mandatory in selected high-risk professional sports. Its impact on the rates of sports-related sudden cardiac death (SCD) is unknown. We aimed to study the incidence, causes and time trends of sports-related SCD in comparison to SCD unrelated to exercise in Switzerland. We reviewed all forensic reports of SCDs of the German-speaking region of Switzerland in the age group of 10 to 39 years, occurring between 1999 and 2010. Cases were classified into three categories based on whether or not deaths were associated with sports: no sports (NONE), recreational sports (REC), and competitive sports (COMP). Over the 12-year study period, 349 SCD cases were recorded (mean age 30±7 years, 76.5% male); 297 cases were categorized as NONE, 31 as REC, and 21 as COMP. Incidences of SCD per 100,000 person-years [mean (95% CI)] were the lowest in REC [0.43 (0.35-0.56)], followed by COMP [1.19 (0.89-1.60)] and NONE [2.46 (2.27-2.66)]. In all three categories, coronary artery disease (CAD) with or without acute myocardial infarction (MI) was the most common cause of SCD. Three professional athletes were identified in COMP category which all had SCD due to acute MI. There were no time trends, neither in overall, nor in cause-specific incidences of SCD. The incidence of SCD in young individuals in Switzerland is low, both related and unrelated to sports. In regions, like Switzerland, where CAD is the leading cause of SCD associated with competitions, screening for cardiovascular risk factors in addition to the current PPS recommendations might be indicated to improve detection of silent CAD and further decrease the incidence of SCD.

  16. A principled relation between reading and naming in acquired and developmental anomia: Surface dyslexia following impairment in the phonological output lexicon

    Directory of Open Access Journals (Sweden)

    Naama eFriedmann

    2016-03-01

    from it to lexical semantics. This pattern was shown both by the adults with acquired anomia and by the participants with developmental anomia. These results thus suggest a principled relation between anomia and dyslexia, and point to a distinct type of surface dyslexia. They further show the possibility of good comprehension of written words when the phonological output stages are impaired.

  17. CVC related infections reported from Salam Center for Cardiac Surgery of Khartoum

    Directory of Open Access Journals (Sweden)

    Margherita Scapaticci

    2010-06-01

    Full Text Available Introduction: Central venous catheter (CVC plays an essential part in clinical management of patients admitted in Intensive Care Unit (ICU, even though catheterization is an invasive procedure that may facilitate bacterial migration from the skin surrounding the catheter insertion site to the catheter tip, representing a risk factor for the arise of bacteraemia and sepsis. Aim of our study was to assess the prevalence of micro-organisms found as responsibles of CVC-related infections and check their correspondence with those found in blood cultures collected from the same patients. Methods: The study was conduced from April 2008 to March 2009. In this period were analysed 29 CVC samples sent from ICU to the laboratory of the Salam Center for Cardiac Surgery of Khartoum (Sudan. CVC was removed after pericatheter skin disinfection and its tip was cut, put in a sterile container and finally sent to the laboratory, where it was immersed in Brain Heart Infusion (BHI and incubated at 37°C.A first culture of the sample on Blood Agar plate was done after an incubation period of 1 hour, the second one after 24 hours. In case of bacterial growth were practiced identification and sensitivity test of the isolated bacteria. Results: Of the 29 analysed samples 38% showed bacterial growth of which 27% caused by gram positive and 73% by gram negative bacteria. The identification tests showed also that among gram positive-related infection predominated those caused by Methicillin-Resistent Staphylococcus aureus (MRSA (67%, while among the gram negative infections predominated those caused by Pseudomonas spp (57%, followed by Enterobacter spp and Serratia spp. Conclusion: All the above mentioned infections were confirmed by examination of blood cultures collected simultaneously from the same patients. Furthermore the study showed that 73% of infections affected post-operative patients rather than those waiting for surgery.

  18. The effect of harmeful elements in production of iron in relation to input and output material balance

    Directory of Open Access Journals (Sweden)

    P. Besta

    2012-07-01

    Full Text Available The main objectives of blast-furnace operators include maximum production of pig iron of required chemical composition at minimal cost. This can be ensured only in case of quality raw material basis and trouble-free operation of blast-furnace. Both parameters are influenced by the concentration of undesirable elements. The negative elements contained in the blast-furnace raw materials cause many technological problems in the sintering as well as in the blast-furnace process. These are mainly heavy metals and alkaline carbonates. The article deals with the analysis of material balance of zinc and selected alkaline carbonates contents in the input raw materials and output products of the blast-furnace.

  19. Hemodynamic changes during weaning: can we assess and predict cardiac-related weaning failure by transthoracic echocardiography?

    Science.gov (United States)

    Voga, Gorazd

    2010-01-01

    Cardiac-related failure of weaning from mechanical ventilation is an important reason for prolonged mechanical ventilation, intensive care unit treatment, and increased morbidity and mortality. When transthoracic echocardiography (TTE) is routinely performed before a weaning trial, patients at high risk of cardiac-related failure can be detected by low left ventricular (LV) ejection fraction, diastolic dysfunction, and elevated LV filling pressure. During the weaning trial, a further increase of LV filling pressure and progression of diastolic failure can be observed by repeated TTE. Owing to certain limitations concerning patients and methodology, TTE cannot be employed in every patient and invasive hemodynamic monitoring is still mandatory in selected patients with repetitive weaning failure.

  20. A novel fission-independent role of dynamin-related protein 1 in cardiac mitochondrial respiration.

    Science.gov (United States)

    Zhang, Huiliang; Wang, Pei; Bisetto, Sara; Yoon, Yisang; Chen, Quan; Sheu, Shey-Shing; Wang, Wang

    2017-02-01

    Mitochondria in adult cardiomyocytes exhibit static morphology and infrequent dynamic changes, despite the high abundance of fission and fusion regulatory proteins in the heart. Previous reports have indicated that fusion proteins may bear functions beyond morphology regulation. Here, we investigated the role of fission protein, dynamin-related protein 1 (DRP1), on mitochondrial respiration regulation in adult cardiomyocytes. By using genetic or pharmacological approaches, we manipulated the activity or protein level of fission and fusion proteins and found they mildly influenced mitochondrial morphology in adult rodent cardiomyocytes, which is in contrast to their significant effect in H9C2 cardiac myoblasts. Intriguingly, inhibiting endogenous DRP1 by dominant-negative DRP1 mutation (K38A), shRNA, or Mdivi-1 suppressed maximal respiration and respiratory control ratio in isolated mitochondria from adult mouse heart or in adult cardiomyocytes from rat. Meanwhile, basal respiration was increased due to increased proton leak. Facilitating mitofusin-mediated fusion by S3 compound, however, failed to inhibit mitochondrial respiration in adult cardiomyocytes. Mechanistically, DRP1 inhibition did not affect the maximal activity of individual respiratory chain complexes or the assembly of supercomplexes. Knocking out cyclophilin D, a regulator of mitochondrial permeability transition pore (mPTP), abolished the effect of DRP1 inhibition on respiration. Finally, DRP1 inhibition decreased transient mPTP-mediated mitochondrial flashes, delayed laser-induced mPTP opening and suppressed mitochondrial reactive oxygen species (ROS). These results uncover a novel non-canonical function of the fission protein, DRP1 in maintaining or positively stimulating mitochondrial respiration, bioenergetics and ROS signalling in adult cardiomyocyte, which is likely independent of morphological changes. Published on behalf of the European Society of Cardiology. All rights reserved. © The

  1. Is Baseline Cardiac Autonomic Modulation Related to Performance and Physiological Responses Following a Supramaximal Judo Test?

    Science.gov (United States)

    Blasco-Lafarga, Cristina; Martínez-Navarro, Ignacio; Mateo-March, Manuel

    2013-01-01

    Little research exists concerning Heart Rate (HR) Variability (HRV) following supramaximal efforts focused on upper-body explosive strength-endurance. Since they may be very demanding, it seems of interest to analyse the relationship among performance, lactate and HR dynamics (i.e. HR, HRV and complexity) following them; as well as to know how baseline cardiac autonomic modulation mediates these relationships. The present study aimed to analyse associations between baseline and post-exercise HR dynamics following a supramaximal Judo test, and their relationship with lactate, in a sample of 22 highly-trained male judoists (20.70±4.56 years). A large association between the increase in HR from resting to exercise condition and performance suggests that individuals exerted a greater sympathetic response to achieve a better performance (Rating of Perceived Exertion: 20; post-exercise peak lactate: 11.57±2.24 mmol/L; 95.76±4.13 % of age-predicted HRmax). Athletes with higher vagal modulation and lower sympathetic modulation at rest achieved both a significant larger ∆HR and a faster post-exercise lactate removal. A enhanced resting parasympathetic modulation might be therefore related to a further usage of autonomic resources and a better immediate metabolic recovery during supramaximal exertions. Furthermore, analyses of variance displayed a persistent increase in α1 and a decrease in lnRMSSD along the 15 min of recovery, which are indicative of a diminished vagal modulation together with a sympathovagal balance leaning to sympathetic domination. Eventually, time-domain indices (lnRMSSD) showed no lactate correlations, while nonlinear indices (α1 and lnSaEn) appeared to be moderate to strongly correlated with it, thus pointing to shared mechanisms between neuroautonomic and metabolic regulation. PMID:24205273

  2. Relation of isovolumic times after cardiac resynchronization therapy to improvement in exercise capacity

    NARCIS (Netherlands)

    Jansen, A.H.M.; Peels, C.H.; Bracke, F.A.L.E.; Dantzig, van J.M.; Meijer, A.; van der Voort, P.H.; Gelder, van L.M.; Korsten, H.H.M.; Hemel, van N.M.

    2007-01-01

    M-mode echocardiography (using the septal-to-posterior wall motion delay [SPWMD]) and color-coded tissue Doppler imaging (TDI; using the septal-to-lateral delay in peak systolic velocity) have been proposed for assessment of left ventricular (LV) dyssynchrony and prediction of response to cardiac

  3. Infarct-like acute myocarditis: relation between electrocardiographic findings and myocardial damage as assessed by cardiac magnetic resonance imaging.

    Science.gov (United States)

    Nucifora, Gaetano; Miani, Daniela; Di Chiara, Antonio; Piccoli, Gianluca; Artico, Jessica; Puppato, Michela; Slavich, Gianaugusto; De Biasio, Marzia; Gasparini, Daniele; Proclemer, Alessandro

    2013-03-01

    Acute myocarditis (AM) may occasionally have an infarct-like presentation. The aim of the present study was to investigate the relation between electrocardiographic (ECG) findings in this group of patients and myocardial damage assessed by cardiac magnetic resonance imaging (MRI) with the late gadolinium enhancement (LGE) technique. Myocardial damage may be associated with ECG changes in infarct-like AM. Forty-one consecutive patients (36 males; mean age, 36 ± 12 years) with diagnosis of AM according to cardiac MRI Lake Louise criteria and infarct-like presentation were included. The relation between site of ST-segment elevation (STE), sum of STE (sumSTE), time to normalization of STE, and development of negative T wave with the extent of LGE (expressed as % of left ventricular mass [%LV LGE]), was evaluated. Most (80%) patients presented with inferolateral STE; mean sumSTE was 5 ± 3 mm. Normalization of STE occurred within 24 hours in 20 (49%) patients. Development of negative T wave occurred in 28 (68%) patients. Cardiac MRI showed LGE in all patients; mean %LV LGE was 9.6 ± 7.2%. Topographic agreement between site of STE and LGE was 68%. At multivariate analysis, sumSTE (β = 0.42, P 24 hours (β = 0.39, P 24 hours, and development of negative T wave) may help to identify patients with larger areas of myocardial damage. © 2012 Wiley Periodicals, Inc.

  4. Lactate up-regulates the expression of lactate oxidation complex-related genes in left ventricular cardiac tissue of rats.

    Directory of Open Access Journals (Sweden)

    Daniele Gabriel-Costa

    Full Text Available Besides its role as a fuel source in intermediary metabolism, lactate has been considered a signaling molecule modulating lactate-sensitive genes involved in the regulation of skeletal muscle metabolism. Even though the flux of lactate is significantly high in the heart, its role on regulation of cardiac genes regulating lactate oxidation has not been clarified yet. We tested the hypothesis that lactate would increase cardiac levels of reactive oxygen species and up-regulate the expression of genes related to lactate oxidation complex.Isolated hearts from male adult Wistar rats were perfused with control, lactate or acetate (20mM added Krebs-Henseleit solution during 120 min in modified Langendorff apparatus. Reactive oxygen species (O2●-/H2O2 levels, and NADH and NADPH oxidase activities (in enriched microsomal or plasmatic membranes, respectively were evaluated by fluorimetry while SOD and catalase activities were evaluated by spectrophotometry. mRNA levels of lactate oxidation complex and energetic enzymes MCT1, MCT4, HK, LDH, PDH, CS, PGC1α and COXIV were quantified by real time RT-PCR. Mitochondrial DNA levels were also evaluated. Hemodynamic parameters were acquired during the experiment. The key findings of this work were that lactate elevated cardiac NADH oxidase activity but not NADPH activity. This response was associated with increased cardiac O2●-/H2O2 levels and up-regulation of MCT1, MCT4, LDH and PGC1α with no changes in HK, PDH, CS, COXIV mRNA levels and mitochondrial DNA levels. Lactate increased NRF-2 nuclear expression and SOD activity probably as counter-regulatory responses to increased O2●-/H2O2.Our results provide evidence for lactate-induced up-regulation of lactate oxidation complex associated with increased NADH oxidase activity and cardiac O2●-/H2O2 driving to an anti-oxidant response. These results unveil lactate as an important signaling molecule regulating components of the lactate oxidation complex in

  5. Distinguishing between tertiary and secondary facilities: a case study of cardiac diagnostic-related groups (DRGs).

    Science.gov (United States)

    Rouse, Paul; Arulambalam, Ajit; Correa, Ralph; Ullman, Cornelia

    2010-05-14

    To develop a classification of tertiary cardiac DRGs in order to investigate differences in tertiary/secondary product mix across New Zealand district health boards (DHBs). 67 DRGs from 85,442 cardiac cases were analysed using cost weights and patient comorbidity complexity levels, which were used as a proxy for complexity. The research found high variability of severity within some DRGs. 5 DHBs are the main providers of 27 DRGs which are high cost and identified as tertiary by several ADHB clinicians; the same 5 DHBs have on average higher severity by DRG than the other DHBs. NZ tertiary hospitals have a product mix of DRGs with higher complexity than secondary hospitals. Funding based on case weights needs to recognise the additional resource requirements for this higher complexity.

  6. Age-related normal structural and functional ventricular values in cardiac function assessed by magnetic resonance

    International Nuclear Information System (INIS)

    Fiechter, Michael; Gaemperli, Oliver; Kaufmann, Philipp A; Fuchs, Tobias A; Gebhard, Catherine; Stehli, Julia; Klaeser, Bernd; Stähli, Barbara E; Manka, Robert; Manes, Costantina; Tanner, Felix C

    2013-01-01

    The heart is subject to structural and functional changes with advancing age. However, the magnitude of cardiac age-dependent transformation has not been conclusively elucidated. This retrospective cardiac magnetic resonance (CMR) study included 183 subjects with normal structural and functional ventricular values. End systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) were obtained from the left and the right ventricle in breath-hold cine CMR. Patients were classified into four age groups (20–29, 30–49, 50–69, and ≥70 years) and cardiac measurements were compared using Pearson’s rank correlation over the four different groups. With advanced age a slight but significant decrease in ESV (r=−0.41 for both ventricles, P<0.001) and EDV (r=−0.39 for left ventricle, r=−0.35 for right ventricle, P<0.001) were observed associated with a significant increase in left (r=0.28, P<0.001) and right (r=0.27, P<0.01) ventricular EF reaching a maximal increase in EF of +8.4% (P<0.001) for the left and +6.1% (P<0.01) for the right ventricle in the oldest compared to the youngest patient group. Left ventricular myocardial mass significantly decreased over the four different age groups (P<0.05). The aging process is associated with significant changes in left and right ventricular EF, ESV and EDV in subjects with no cardiac functional and structural abnormalities. These findings underline the importance of using age adapted values as standard of reference when evaluating CMR studies

  7. Goal striving strategies and effort mobilization: When implementation intentions reduce effort-related cardiac activity during task performance.

    Science.gov (United States)

    Freydefont, Laure; Gollwitzer, Peter M; Oettingen, Gabriele

    2016-09-01

    Two experiments investigate the influence of goal and implementation intentions on effort mobilization during task performance. Although numerous studies have demonstrated the beneficial effects of setting goals and making plans on performance, the effects of goals and plans on effort-related cardiac activity and especially the cardiac preejection period (PEP) during goal striving have not yet been addressed. According to the Motivational Intensity Theory, participants should increase effort mobilization proportionally to task difficulty as long as success is possible and justified. Forming goals and making plans should allow for reduced effort mobilization when participants perform an easy task. However, when the task is difficult, goals and plans should differ in their effect on effort mobilization. Participants who set goals should disengage, whereas participants who made if-then plans should stay in the field showing high effort mobilization during task performance. As expected, using an easy task in Experiment 1, we observed a lower cardiac PEP in both the implementation intention and the goal intention condition than in the control condition. In Experiment 2, we varied task difficulty and demonstrated that while participants with a mere goal intention disengaged from difficult tasks, participants with an implementation intention increased effort mobilization proportionally with task difficulty. These findings demonstrate the influence of goal striving strategies (i.e., mere goals vs. if-then plans) on effort mobilization during task performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. The relative contribution of paracine effect versus direct differentiation on adipose-derived stem cell transplantation mediated cardiac repair.

    Directory of Open Access Journals (Sweden)

    Dezhong Yang

    Full Text Available BACKGROUND: Recent studies have demonstrated that transplantation of adipose-derived stem cell (ADSC can improve cardiac function in animal models of myocardial infarction (MI. However, the mechanisms underlying the beneficial effect are not fully understood. In this study, we characterized the paracrine effect of transplanted ADSC and investigated its relative importance versus direct differentiation in ADSC transplantation mediated cardiac repair. METHODOLOGY/PRINCIPAL FINDINGS: MI was experimentally induced in mice by ligation of the left anterior descending coronary artery. Either human ADSC, conditioned medium (CM collected from the same amount of ADSC or control medium was injected into the peri-infarct region immediately after MI. Compared with the control group, both ADSC and ADSC-CM significantly reduced myocardial infarct size and improved cardiac function. The therapeutic efficacy of ADSC was moderately superior to ADSC-CM. ADSC-CM significantly reduced cardiomyocyte apoptosis in the infarct border zone, to a similar degree with ADSC treatment. ADSC enhanced angiogenesis in the infarct border zone, but to a stronger degree than that seen in the ADSC-CM treatment. ADSC was able to differentiate to endothelial cell and smooth muscle cell in post-MI heart; these ADSC-derived vascular cells amount to about 9% of the enhanced angiogenesis. No cardiomyocyte differentiated from ADSC was found. CONCLUSIONS: ADSC-CM is sufficient to improve cardiac function of infarcted hearts. The therapeutic function of ADSC transplantation is mainly induced by paracrine-mediated cardioprotection and angiogenesis, while ADSC differentiation contributes a minor benefit by being involved in angiogenesis. Highlights 1 ADSC-CM is sufficient to exert a therapeutic potential. 2. ADSC was able to differentiate to vascular cells but not cardiomyocyte. 3. ADSC derived vascular cells amount to about 9% of the enhanced angiogenesis. 4. Paracrine effect is the major

  9. Correlation between changes in diastolic dysfunction and health-related quality of life after cardiac rehabilitation program in dilated cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Sherin H.M. Mehani

    2013-03-01

    Full Text Available Chronic heart failure (CHF is a complex syndrome characterized by progressive decline in left ventricular function, low exercise tolerance and raised mortality and morbidity. Left ventricular diastolic dysfunction plays a major role in CHF and progression of most cardiac diseases. The current recommended goals can theoretically be accomplished via exercise and pharmacological therapy so the aim of the present study was to evaluate the impact of cardiac rehabilitation program on diastolic dysfunction and health related quality of life and to determine the correlation between changes in left ventricular diastolic dysfunction and domains of health-related quality of life (HRQoL. Forty patients with chronic heart failure were diagnosed as having dilated cardiomyopathy (DCM with systolic and diastolic dysfunction. The patients were equally and randomly divided into training and control groups. Only 30 of them completed the study duration. The training group participated in rehabilitation program in the form of circuit-interval aerobic training adjusted according to 55–80% of heart rate reserve for a period of 7 months. Circuit training improved both diastolic and systolic dysfunction in the training group. On the other hand, only a significant correlation was found between improvement in diastolic dysfunction and health related quality of life measured by Kansas City Cardiomyopathy Questionnaire. It was concluded that improvement in diastolic dysfunction as a result of rehabilitation program is one of the important underlying mechanisms responsible for improvement in health-related quality of life in DCM patients.

  10. Ongoing myocardial damage relates to cardiac sympathetic nervous disintegrity in patients with heart failure

    International Nuclear Information System (INIS)

    Arimoto, Takanori; Takeishi, Yasuchika; Niizeki, Takeshi

    2005-01-01

    Iodine-123-metaiodobenzylguanidine ( 123 I-MIBG) has been used to assess the integrity and function of the cardiac sympathetic nervous system in patients with heart failure. Heart-type fatty acid binding protein (H-FABP) is released into the circulation when the myocardium is injured, and H-FABP has been recently used as a novel marker for the diagnosis of ongoing myocardial damage. The aim of the present study was to compare cardiac sympathetic nervous activity assessed by 123 I-MIBG imaging with serum levels of H-FABP in patients with heart failure. Fifty patients with chronic heart failure were studied. 123 I-MIBG imaging was carried out at 30 min (early) and 240 min (delayed) after the tracer injection. We measured serum levels of H-FABP using a sandwich enzyme linked immunosorbent assay. Heart to mediastinum (H/M) ratios of 123 I-MIBG decreased and washout rate increased with higher New York Heart Association (NYHA) functional class. H-FABP, norepinephrine and brain natriuretic peptide (BNP) levels increased as the severity of NYHA class advanced. Delayed H/M ratio was significantly correlated with H-FABP (r=-0.296, p=0.029) and BNP (r=-0.335, p=0.0213). Myocardial washout rate of 123 I-MIBG was also correlated with H-FABP (r=0.469, p 123 I-MIBG imaging is an appropriate approach to evaluate non-invasively not only cardiac sympathetic nervous activity, but also latent ongoing myocardial damage in the failing heart. (author)

  11. Cardiac function of the naked mole-rat: ecophysiological responses to working underground.

    Science.gov (United States)

    Grimes, Kelly M; Voorhees, Andrew; Chiao, Ying Ann; Han, Hai-Chao; Lindsey, Merry L; Buffenstein, Rochelle

    2014-03-01

    The naked mole-rat (NMR) is a strictly subterranean rodent with a low resting metabolic rate. Nevertheless, it can greatly increase its metabolic activity to meet the high energetic demands associated with digging through compacted soils in its xeric natural habitat where food is patchily distributed. We hypothesized that the NMR heart would naturally have low basal function and exhibit a large cardiac reserve, thereby mirroring the species' low basal metabolism and large metabolic scope. Echocardiography showed that young (2-4 yr old) healthy NMRs have low fractional shortening (28 ± 2%), ejection fraction (43 ± 2%), and cardiac output (6.5 ± 0.4 ml/min), indicating low basal cardiac function. Histology revealed large NMR cardiomyocyte cross-sectional area (216 ± 10 μm(2)) and cardiac collagen deposition of 2.2 ± 0.4%. Neither of these histomorphometric traits was considered pathological, since biaxial tensile testing showed no increase in passive ventricular stiffness. NMR cardiomyocyte fibers showed a low degree of rotation, contributing to the observed low NMR cardiac contractility. Interestingly, when the exercise mimetic dobutamine (3 μg/g ip) was administered, NMRs showed pronounced increases in fractional shortening, ejection fraction, cardiac output, and stroke volume, indicating an increased cardiac reserve. The relatively low basal cardiac function and enhanced cardiac reserve of NMRs are likely to be ecophysiological adaptations to life in an energetically taxing environment.

  12. Objectively measured daily physical activity related to cardiac size in young children

    DEFF Research Database (Denmark)

    Dencker, M; Thorsson, O; Karlsson, M K

    2009-01-01

    Training studies in children have suggested that endurance training can give enlargement of cardiac dimensions. This relationship has not been studied on a population-based level in young children with objective methods. A cross-sectional study was made of 248 children (140 boys and 108 girls...... activity per day (VPA) was calculated. Acceptable accelerometer and echocardiography measurements were obtained in 228 children (boys=127, girls=101). Univariate correlations between VPA and LVDD were indexed for BSA in boys (r=0.27, Pgirls (r=0.10, NS). Multiple regression analysis showed...

  13. Temporal modification in cardiac rhythmicity of Nephrops norvegicus (Crustacea: Decapoda in relation to trawl capture stress

    Directory of Open Access Journals (Sweden)

    Jacopo Aguzzi

    2005-09-01

    Full Text Available The effects of trawling on cardiac rhythmicity of Nephrops norvegicus (L. are still mostly unknown. Ultradian rhythms reported in previous studies may result from trawling capture stress, thus disappearing following acclimatisation to laboratory conditions. To test this hypothesis, 34 time series of cardiac activity data recorded in constant darkness were studied by Fourier analysis. Spectral decomposition of time series was obtained by defining the fundamental or circadian harmonic (CH in 24-h together with 9 submultiples of this period. The power content (PC of each harmonic was estimated in data segments of 24-h duration (days, giving graphic matrices of PC values over consecutive days. Values of PC for 9 submultiples were summed and studied in a block named ultradian band (UB. The modification in the PC of the CH and of the UB was evaluated during laboratory acclimatisation. A significant increase in the PC of the circadian harmonic component (CH over consecutive days of testing was observed. These findings suggest that, rather than being a product of dim light environmental fluctuations experienced by the animals from the deep waters of the continental slope, ultradian periodicity could well be caused by the stress of capture.

  14. Bibliometric Assessment of European and Sub-Saharan African Research Output on Poverty-Related and Neglected Infectious Diseases from 2003 to 2011.

    Science.gov (United States)

    Breugelmans, J Gabrielle; Makanga, Michael M; Cardoso, Ana Lúcia V; Mathewson, Sophie B; Sheridan-Jones, Bethan R; Gurney, Karen A; Mgone, Charles S

    2015-08-01

    The European & Developing Countries Clinical Trials Partnership (EDCTP) is a partnership of European and sub-Saharan African countries that aims to accelerate the development of medical interventions against poverty-related diseases (PRDs). A bibliometric analysis was conducted to 1) measure research output from European and African researchers on PRDs, 2) describe collaboration patterns, and 3) assess the citation impact of clinical research funded by EDCTP. Disease-specific research publications were identified in Thomson Reuters Web of Science using search terms in titles, abstracts and keywords. Publication data, including citation counts, were extracted for 2003-2011. Analyses including output, share of global papers, normalised citation impact (NCI), and geographical distribution are presented. Data are presented as five-year moving averages. European EDCTP member countries accounted for ~33% of global research output in PRDs and sub-Saharan African countries for ~10% (2007-2011). Both regions contributed more to the global research output in malaria (43.4% and 22.2%, respectively). The overall number of PRD papers from sub-Saharan Africa increased markedly (>47%) since 2003, particularly for HIV/AIDS (102%) and tuberculosis (TB) (81%), and principally involving Southern and East Africa. For 2007-2011, European and sub-Saharan African research collaboration on PRDs was highly cited compared with the world average (NCI in brackets): HIV/AIDS 1.62 (NCI: 1.16), TB 2.11 (NCI: 1.06), malaria 1.81 (NCI: 1.22), and neglected infectious diseases 1.34 (NCI: 0.97). The NCI of EDCTP-funded papers for 2003-2011 was exceptionally high for HIV/AIDS (3.24), TB (4.08) and HIV/TB co-infection (5.10) compared with global research benchmarks (1.14, 1.05 and 1.35, respectively). The volume and citation impact of papers from sub-Saharan Africa has increased since 2003, as has collaborative research between Europe and sub-Saharan Africa. >90% of publications from EDCTP

  15. Bibliometric Assessment of European and Sub-Saharan African Research Output on Poverty-Related and Neglected Infectious Diseases from 2003 to 2011

    Science.gov (United States)

    Gurney, Karen A.; Mgone, Charles S.

    2015-01-01

    Background The European & Developing Countries Clinical Trials Partnership (EDCTP) is a partnership of European and sub-Saharan African countries that aims to accelerate the development of medical interventions against poverty-related diseases (PRDs). A bibliometric analysis was conducted to 1) measure research output from European and African researchers on PRDs, 2) describe collaboration patterns, and 3) assess the citation impact of clinical research funded by EDCTP. Methodology/Principal Findings Disease-specific research publications were identified in Thomson Reuters Web of Science using search terms in titles, abstracts and keywords. Publication data, including citation counts, were extracted for 2003–2011. Analyses including output, share of global papers, normalised citation impact (NCI), and geographical distribution are presented. Data are presented as five-year moving averages. European EDCTP member countries accounted for ~33% of global research output in PRDs and sub-Saharan African countries for ~10% (2007–2011). Both regions contributed more to the global research output in malaria (43.4% and 22.2%, respectively). The overall number of PRD papers from sub-Saharan Africa increased markedly (>47%) since 2003, particularly for HIV/AIDS (102%) and tuberculosis (TB) (81%), and principally involving Southern and East Africa. For 2007–2011, European and sub-Saharan African research collaboration on PRDs was highly cited compared with the world average (NCI in brackets): HIV/AIDS 1.62 (NCI: 1.16), TB 2.11 (NCI: 1.06), malaria 1.81 (NCI: 1.22), and neglected infectious diseases 1.34 (NCI: 0.97). The NCI of EDCTP-funded papers for 2003–2011 was exceptionally high for HIV/AIDS (3.24), TB (4.08) and HIV/TB co-infection (5.10) compared with global research benchmarks (1.14, 1.05 and 1.35, respectively). Conclusions The volume and citation impact of papers from sub-Saharan Africa has increased since 2003, as has collaborative research between Europe and

  16. Bibliometric Assessment of European and Sub-Saharan African Research Output on Poverty-Related and Neglected Infectious Diseases from 2003 to 2011.

    Directory of Open Access Journals (Sweden)

    J Gabrielle Breugelmans

    2015-08-01

    Full Text Available The European & Developing Countries Clinical Trials Partnership (EDCTP is a partnership of European and sub-Saharan African countries that aims to accelerate the development of medical interventions against poverty-related diseases (PRDs. A bibliometric analysis was conducted to 1 measure research output from European and African researchers on PRDs, 2 describe collaboration patterns, and 3 assess the citation impact of clinical research funded by EDCTP.Disease-specific research publications were identified in Thomson Reuters Web of Science using search terms in titles, abstracts and keywords. Publication data, including citation counts, were extracted for 2003-2011. Analyses including output, share of global papers, normalised citation impact (NCI, and geographical distribution are presented. Data are presented as five-year moving averages. European EDCTP member countries accounted for ~33% of global research output in PRDs and sub-Saharan African countries for ~10% (2007-2011. Both regions contributed more to the global research output in malaria (43.4% and 22.2%, respectively. The overall number of PRD papers from sub-Saharan Africa increased markedly (>47% since 2003, particularly for HIV/AIDS (102% and tuberculosis (TB (81%, and principally involving Southern and East Africa. For 2007-2011, European and sub-Saharan African research collaboration on PRDs was highly cited compared with the world average (NCI in brackets: HIV/AIDS 1.62 (NCI: 1.16, TB 2.11 (NCI: 1.06, malaria 1.81 (NCI: 1.22, and neglected infectious diseases 1.34 (NCI: 0.97. The NCI of EDCTP-funded papers for 2003-2011 was exceptionally high for HIV/AIDS (3.24, TB (4.08 and HIV/TB co-infection (5.10 compared with global research benchmarks (1.14, 1.05 and 1.35, respectively.The volume and citation impact of papers from sub-Saharan Africa has increased since 2003, as has collaborative research between Europe and sub-Saharan Africa. >90% of publications from EDCTP

  17. Quantitation of cardiac sympathetic innervation in rabbits using 11C-hydroxyephedrine PET: relation to 123I-MIBG uptake

    International Nuclear Information System (INIS)

    Nomura, Yusuke; Kajinami, Kouji; Matsunari, Ichiro; Takamatsu, Hiroyuki; Murakami, Yoshihiro; Matsuya, Takahiro; Chen, Wei-Ping; Taki, Junichi; Nakajima, Kenichi; Nekolla, Stephan G.

    2006-01-01

    Although 11 C-hydroxyephedrine ( 11 C-HED) PET is used to map cardiac sympathetic innervation, no studies have shown the feasibility of quantitation of 11 C-HED PET in small- to medium-sized animals. Furthermore, its relation to 123 I-MIBG uptake, the most widely used sympathetic nervous tracer, is unknown. The aims of this study were to establish in vivo sympathetic nerve imaging in rabbits using 11 C-HED PET, and to compare the retention of 11 C-HED with that of 123 I-MIBG. Twelve rabbits were assigned to three groups; control (n=4), chemical denervation by 6-hydroxydopamine (6-OHDA) (n=4) and reserpine treated to inhibit vesicular uptake (n=4). After simultaneous injection of 11 C-HED and 123 I-MIBG, all animals underwent dynamic 11 C-HED PET for 40 min with arterial blood sampling. The 11 C-HED retention fraction and normalised 11 C-HED activity measured by tissue sampling were compared with those measured by PET. Both the 11 C-HED retention fraction and the normalised 11 C-HED activity measured by PET correlated closely with those measured by tissue sampling (R=0.96027, p 11 C-HED and 123 I-MIBG. Reserpine pretreatment reduced 11 C-HED retention by 50%, but did not reduce 123 I-MIBG retention at 40 min after injection. Non-invasive quantitation of cardiac sympathetic innervation using 11 C-HED PET is feasible and gives reliable estimates of cardiac sympathetic innervation in rabbits. Additionally, although both 11 C-HED and 123 I-MIBG are specific for sympathetic neurons, 11 C-HED may be more specific for intravesicular uptake than 123 I-MIBG in some situations, such as that seen in reserpine pretreatment. (orig.)

  18. Survival after out-of-hospital cardiac arrest in relation to sex: a nationwide registry-based study.

    Science.gov (United States)

    Wissenberg, Mads; Hansen, Carolina Malta; Folke, Fredrik; Lippert, Freddy K; Weeke, Peter; Karlsson, Lena; Rajan, Shahzleen; Søndergaard, Kathrine Bach; Kragholm, Kristian; Christensen, Erika Frischknecht; Nielsen, Søren L; Køber, Lars; Gislason, Gunnar H; Torp-Pedersen, Christian

    2014-09-01

    Crude survival has increased following an out-of-hospital cardiac arrest (OHCA). We aimed to study sex-related differences in patient characteristics and survival during a 10-year study period. Patients≥12 years old with OHCA of a presumed cardiac cause, and in whom resuscitation was attempted, were identified through the Danish Cardiac Arrest Registry 2001-2010. A total of 19,372 patients were included. One-third were female, with a median age of 75 years (IQR 65-83). Compared to females, males were five years younger; and less likely to have severe comorbidities, e.g., chronic obstructive pulmonary disease (12.8% vs. 16.5%); but more likely to have arrest outside of the home (29.4% vs. 18.7%), receive bystander CPR (32.9% vs. 25.9%), and have a shockable rhythm (32.6% vs. 17.2%), all p<0.001. Thirty-day crude survival increased in males (3.0% in 2001 to 12.9% in 2010); and in females (4.8% in 2001 to 6.7% in 2010), p<0.001. Multivariable logistic regression analyses adjusted for patient characteristics including comorbidities, showed no survival difference between sexes in patients with a non-shockable rhythm (OR 1.00; CI 0.72-1.40), while female sex was positively associated with survival in patients with a shockable rhythm (OR 1.31; CI 1.07-1.59). Analyses were rhythm-stratified due to interaction between sex and heart rhythm; there was no interaction between sex and calendar-year. Temporal increase in crude survival was more marked in males due to poorer prognostic characteristics in females with a lower proportion of shockable rhythm. In an adjusted model, female sex was positively associated with survival in patients with a shockable rhythm. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Enhanced performance CCD output amplifier

    Science.gov (United States)

    Dunham, Mark E.; Morley, David W.

    1996-01-01

    A low-noise FET amplifier is connected to amplify output charge from a che coupled device (CCD). The FET has its gate connected to the CCD in common source configuration for receiving the output charge signal from the CCD and output an intermediate signal at a drain of the FET. An intermediate amplifier is connected to the drain of the FET for receiving the intermediate signal and outputting a low-noise signal functionally related to the output charge signal from the CCD. The amplifier is preferably connected as a virtual ground to the FET drain. The inherent shunt capacitance of the FET is selected to be at least equal to the sum of the remaining capacitances.

  20. The left ventricle as a mechanical engine: from Leonardo da Vinci to the echocardiographic assessment of peak power output-to-left ventricular mass.

    Science.gov (United States)

    Dini, Frank L; Guarini, Giacinta; Ballo, Piercarlo; Carluccio, Erberto; Maiello, Maria; Capozza, Paola; Innelli, Pasquale; Rosa, Gian M; Palmiero, Pasquale; Galderisi, Maurizio; Razzolini, Renato; Nodari, Savina

    2013-03-01

    The interpretation of the heart as a mechanical engine dates back to the teachings of Leonardo da Vinci, who was the first to apply the laws of mechanics to the function of the heart. Similar to any mechanical engine, whose performance is proportional to the power generated with respect to weight, the left ventricle can be viewed as a power generator whose performance can be related to left ventricular mass. Stress echocardiography may provide valuable information on the relationship between cardiac performance and recruited left ventricular mass that may be used in distinguishing between adaptive and maladaptive left ventricular remodeling. Peak power output-to-mass, obtained during exercise or pharmacological stress echocardiography, is a measure that reflects the number of watts that are developed by 100 g of left ventricular mass under maximal stimulation. Power output-to-mass may be calculated as left ventricular power output per 100 g of left ventricular mass: 100× left ventricular power output divided by left ventricular mass (W/100 g). A simplified formula to calculate power output-to-mass is as follows: 0.222 × cardiac output (l/min) × mean blood pressure (mmHg)/left ventricular mass (g). When the integrity of myocardial structure is compromised, a mismatch becomes apparent between maximal cardiac power output and left ventricular mass; when this occurs, a reduction of the peak power output-to-mass index is observed.

  1. Consenso brasileiro de monitorização e suporte hemodinâmico - parte III: métodos alternativos de monitorização do débito cardíaco e da volemia Brazilian consensus of monitoring and hemodynamic support - part III: alternative methods for cardiac output monitoring and volemia estimation

    Directory of Open Access Journals (Sweden)

    Guilherme Schettino

    2006-03-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A interpretação do débito cardíaco e da pré-carga como números absolutos não traz grandes informações sobre a hemodinâmica do paciente crítico. Em contrapartida, a monitorização da resposta do débito cardíaco à expansão volêmica ou suporte inotrópico é uma ferramenta muito útil na unidade de terapia intensiva, quando o paciente apresenta algum sinal de má perfusão tecidual. Apesar do CAP ser considerado como " padrão-ouro" na avaliação destes parâmetros, foram desenvolvidas tecnologias alternativas bastante confiáveis para a sua monitorização. MÉTODO: O processo de desenvolvimento de recomendações utilizou o método Delphi modificado para criar e quantificar o consenso entre os participantes. A AMIB determinou um coordenador para o consenso, o qual escolheu seis especialistas para comporem o comitê consultivo. Outros 18 peritos de diferentes regiões do país foram selecionados para completar o painel de 25 especialistas, médicos e enfermeiros. Um levantamento bibliográfico na MEDLINE de artigos na língua inglesa foi realizado no período de 1966 a 2004. RESULTADOS: Foram apresentadas recomendações referentes à análise da variação da pressão arterial durante ventilação mecânica, débito cardíaco contínuo por contorno de pulso arterial, débito cardíaco por diluição do lítio, Doppler transesofágico, bioimpedância transtorácica, ecocardiografia e reinalação parcial de gás carbônico. CONCLUSÕES: As novas e menos invasivas técnicas para medida do débito cardíaco, pré-carga e fluidoresponsividade apresentam adequada precisão e podem ser uma alternativa ao uso do CAP em pacientes graves.BACKGROUND AND OBJECTIVES: Cardiac output and preload as absolute data do not offer helpful information about the hemodynamic of critically ill patients. However, monitoring the response of these variables to volume challenge or inotropic drugs is a very useful tool in the

  2. Prevalence of nursing diagnosis of decreased cardiac output and the predictive value of defining characteristics in patients under evaluation for heart transplant Prevalencia del diagnóstico de enfermería de disminución del gasto cardíaco y valor predictivo de las características definidoras en pacientes en fase de evaluación para trasplante cardíaco Prevalência do diagnóstico de enfermagem de débito cardíaco diminuído e valor preditivo das características definidoras em pacientes em avaliação para transplante cardíaco

    OpenAIRE

    Lígia Neres Matos; Tereza Cristina Felippe Guimarães; Marcos Antônio Gomes Brandão; Deyse Conceição Santoro

    2012-01-01

    The purposes of the study were to identify the prevalence of defining characteristics (DC) of decreased cardiac output (DCO) in patients with cardiac insufficiency under evaluation for heart transplantation, and to ascertain the likelihood of defining characteristics being predictive factors for the existence of reduction in cardiac output. Data was obtained by retrospective documental analysis of the clinical records of right-sided heart catheterizations in 38 patients between 2004 and 2009....

  3. Left phrenic nerve anatomy relative to the coronary venous system: Implications for phrenic nerve stimulation during cardiac resynchronization therapy.

    Science.gov (United States)

    Spencer, Julianne H; Goff, Ryan P; Iaizzo, Paul A

    2015-07-01

    The objective of this study was to quantitatively characterize anatomy of the human phrenic nerve in relation to the coronary venous system, to reduce undesired phrenic nerve stimulation during left-sided lead implantations. We obtained CT scans while injecting contrast into coronary veins of 15 perfusion-fixed human heart-lung blocs. A radiopaque wire was glued to the phrenic nerve under CT, then we created three-dimensional models of anatomy and measured anatomical parameters. The left phrenic nerve typically coursed over the basal region of the anterior interventricular vein, mid region of left marginal veins, and apical region of inferior and middle cardiac veins. There was large variation associated with the average angle between nerve and veins. Average angle across all coronary sinus tributaries was fairly consistent (101.3°-111.1°). The phrenic nerve coursed closest to the middle cardiac vein and left marginal veins. The phrenic nerve overlapped a left marginal vein in >50% of specimens. © 2015 Wiley Periodicals, Inc.

  4. Cardiac Arrest: MedlinePlus Health Topic

    Science.gov (United States)

    ... Handouts Cardiac arrest (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Cardiac Arrest updates ... this? GO MEDICAL ENCYCLOPEDIA Cardiac arrest Related Health Topics Arrhythmia CPR Pacemakers and Implantable Defibrillators National Institutes ...

  5. Dependency of blood pressure upon cardiac filling in patients with severe postural hypotension

    DEFF Research Database (Denmark)

    Mehlsen, J; Haedersdal, C; Stokholm, K H

    1994-01-01

    by vasoconstriction. The reduction in cardiac output resulted from reductions in left ventricular end-diastolic volumes with unchanged left ventricular ejection fractions and only moderate increments in heart rate. The study was demonstrated that blood pressure is strongly dependent upon cardiac filling in severe......Autonomic denervation of the vascular bed results theoretically in a stronger dependency of blood pressure upon intravascular volume, and the study described aimed at an investigation of the relation between cardiac filling and arterial blood pressure in patients with severe postural hypotension....... Seven patients were studied during head-up tilt at three different tilt angles using intra-arterial blood pressure recordings and estimates of left ventricular volumes by radioisotope ventriculography. Blood pressure fell dramatically during head-up tilt due to reductions in cardiac output unopposed...

  6. Dependency of blood pressure upon cardiac filling in patients with severe postural hypotension

    DEFF Research Database (Denmark)

    Mehlsen, J; Haedersdal, C; Stokholm, K H

    1994-01-01

    Autonomic denervation of the vascular bed results theoretically in a stronger dependency of blood pressure upon intravascular volume, and the study described aimed at an investigation of the relation between cardiac filling and arterial blood pressure in patients with severe postural hypotension....... Seven patients were studied during head-up tilt at three different tilt angles using intra-arterial blood pressure recordings and estimates of left ventricular volumes by radioisotope ventriculography. Blood pressure fell dramatically during head-up tilt due to reductions in cardiac output unopposed...... by vasoconstriction. The reduction in cardiac output resulted from reductions in left ventricular end-diastolic volumes with unchanged left ventricular ejection fractions and only moderate increments in heart rate. The study was demonstrated that blood pressure is strongly dependent upon cardiac filling in severe...

  7. Plasma homocysteine level in cardiac syndrome X and its relation with duke treadmill score

    International Nuclear Information System (INIS)

    Timurkaynak, T.; Balcioglu, S.; Arslan, U.; Kocaman, Sinan A.; Cengel, A.

    2008-01-01

    Objective was to investigate the plasma homocysteine level and relationship between plasma homocysteine level and duke treadmill score (DTS) in cardiac syndrome X (CSX) patients. Seventy-nine patients (36 male, 43 female, mean age: 50+-8.8 years) admitted to Gazi University Hospital, Ankara, Turkey with typical effort angina, positive stress test and angiographically normal coronary arteries between January and September 2006 were included in this prospective and controlled study. Thirty asymptomatic patients (11 male, 19 female, mean age: 47.6+-8.3 years) with two cardiovascular risk factors were chosen as a control group. Plasma homocysteine level was measured in both groups and DTS was calculated in the CSX group. Plasma homocysteine was measured with AxSYM homocysteine immunoassay method in both groups. Plasma homocysteine level was higher in the CSx group compared to the control group 16.5+-4.9 umol/L, n=79, versus 12.4+-4.1 umol/L, n=30, p<0.001). The DTS was -2.7+-5.3 in the CSX group. There was a negative correlation between the DTS and homocysteine levels in the CSX group. (r=-0.506, p<0.001). Plasma homocysteine level, which is known to cause endothelial dysfunction and microvascular ischemia were higher in CSX patients. Also, this increase in homocysteine level correlated with the DTS, which represents the magnitude of ischemia. (author)

  8. High cardiac vagal control is related to better subjective and objective sleep quality.

    Science.gov (United States)

    Werner, Gabriela G; Ford, Brett Q; Mauss, Iris B; Schabus, Manuel; Blechert, Jens; Wilhelm, Frank H

    2015-03-01

    Cardiac vagal control (CVC) has been linked to both physical and mental health. One critical aspect of health, that has not received much attention, is sleep. We hypothesized that adults with higher CVC--operationalized by high-frequency heart rate variability (HF-HRV)--will exhibit better sleep quality assessed both subjectively (i.e., with Pittsburgh Sleep Quality Index) and objectively (i.e., with polysomnography). HF-HRV was measured in 29 healthy young women during an extended neutral film clip. Participants then underwent full polysomnography to obtain objective measures of sleep quality and HF-HRV during a night of sleep. As expected, higher resting HF-HRV was associated with higher subjective and objective sleep quality (i.e., shorter sleep latency and fewer arousals). HF-HRV during sleep (overall or separated by sleep phases) showed less consistent relationships with sleep quality. These findings indicate that high waking CVC may be a key predictor of healthy sleep. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Relation of Left Atrial Size, Cardiac Morphology, and Clinical Outcome in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Christensen, Nicolaj Lyhne; Dahl, Jordi; Carter-Storch, Rasmus

    2017-01-01

    characterized by higher LV mass index (73 ± 17 g/m² vs. 66 ± 16 g/m² , p=0.03), increased right ventricle (70 ± 14 ml/m² vs. 63 ± 12 ml/m², p=0.01) and LV end-diastolic volume index (84 ± 18 ml/m² vs. 77 ± 16 ml/m², p=0.05), and higher brain natriuretic peptide (BNP). No difference in late enhancement was seen......Left atrial (LA) dilatation in asymptomatic severe aortic stenosis (AS) may be an indicator of advanced disease. The aim was to investigate the association between LA volume index (LAVi) and left ventricular (LV) morphology assessed with cardiac magnetic resonance imaging (cMRI), and to assess...... underwent echocardiography, cMRI, exercise test, and patients were followed for the composite endpoint of death, readmission or aortic valve replacement. AVA index was similar (0.45 ± 0.08 cm² /m² vs. 0.45 ± 0.09 cm², p=0.85) in patients with a dilated and normal LA. On cMRI patients with dilated LA were...

  10. Positive affect and negative affect correlate differently with distress and health-related quality of life in patients with cardiac conditions: Validation of the Danish Global Mood Scale

    DEFF Research Database (Denmark)

    Spindler, Helle; Denollet, Johan; Kruse, Charlotte

    2009-01-01

    The Global Mood Scale (GMS), assessing negative affect (NA) and positive affect (PA), is sensitive to tapping treatment-related changes in patients with cardiac conditions. We examined the psychometric properties of the Danish GMS and the influence of NA and PA on distress and health-related qual...

  11. Use of whole body CT to detect patterns of CPR-related injuries after sudden cardiac arrest.

    Science.gov (United States)

    Dunham, Gregor M; Perez-Girbes, Alexandre; Bolster, Ferdia; Sheehan, Kellie; Linnau, Ken F

    2017-11-09

    We have recently implemented a dedicated sudden cardiac arrest (SCA) - whole-body computed tomography (WBCT) protocol to evaluate SCA patients with return of spontaneous circulation (ROSC) following cardiopulmonary resuscitation (CPR). The aim of this study is to evaluate the number and pattern of CPR-related injuries in ROSC patients with SCA-WBCT. Single-centre retrospective review of 39 patients (13 female; 20 male, mean age 51.8 years) with non-traumatic, out-of-hospital SCA and ROSC and evaluation with dedicated SCA-WBCT over a 10-month period. In-hospital mortality was 54%. CPR-related injuries were detected in 85% (33/39). Chest injuries were most common on WBCT: 85% (33) subjects had rib fractures (mean of 8.5 fractures/subject); 31% (12) sternal fractures; 13% (5) mediastinal haematoma; 10% (4) pneumothorax; 8% (3) pneumomediastinum and 3% (1) haemothorax. Three subjects (8%) had abdominal injuries on WBCT, including one hepatic haematoma with active haemorrhage. CPR-related injuries on WBCT after ROSC are common, with serial rib fractures detected most commonly. An unexpectedly high rate of abdominal injuries was detected on SCA-WBCT. Radiologists need to be attuned to the spectrum of CPR-related injuries in WBCT, including abdominal injuries and subtle rib fractures. • CPR frequently causes injuries. • Radiologists should be aware of the spectrum of CPR related injuries. • Rib fractures are frequent and radiologic findings often subtle. • Clinically unexpected abdominal injuries may be present.

  12. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    Science.gov (United States)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  13. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    LENUS (Irish Health Repository)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient\\'s cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  14. Breast Cancer Laterality Does Not Influence Survival in a Large Modern Cohort: Implications for Radiation-Related Cardiac Mortality

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, Charles E., E-mail: charles.rutter@yale.edu [Department of Therapeutic Radiology, Yale School of Medicine, New Haven, Connecticut (United States); Chagpar, Anees B. [Department of Surgery, Yale School of Medicine, New Haven, Connecticut (United States); Cancer Outcomes, Public Policy and Effectiveness Research Center, Yale School of Medicine, New Haven, Connecticut (United States); Evans, Suzanne B. [Department of Therapeutic Radiology, Yale School of Medicine, New Haven, Connecticut (United States); Cancer Outcomes, Public Policy and Effectiveness Research Center, Yale School of Medicine, New Haven, Connecticut (United States)

    2014-10-01

    not appear to increase the risk of death in this national database relative to right-sided tumors. Consequently, radiation therapy–induced cardiac disease may be less prominent than previously demonstrated.

  15. Analysis of influence mechanism of energy-related carbon emissions in Guangdong: evidence from regional China based on the input-output and structural decomposition analysis.

    Science.gov (United States)

    Wang, Changjian; Wang, Fei; Zhang, Xinlin; Deng, Haijun

    2017-11-01

    It is important to analyze the influence mechanism of energy-related carbon emissions from a regional perspective to effectively achieve reductions in energy consumption and carbon emissions in China. Based on the "energy-economy-carbon emissions" hybrid input-output analysis framework, this study conducted structural decomposition analysis (SDA) on carbon emissions influencing factors in Guangdong Province. Systems-based examination of direct and indirect drivers for regional emission is presented. (1) Direct effects analysis of influencing factors indicated that the main driving factors of increasing carbon emissions were economic and population growth. Carbon emission intensity was the main contributing factor restraining carbon emissions growth. (2) Indirect effects analysis of influencing factors showed that international and interprovincial trades significantly affected the total carbon emissions. (3) Analysis of the effects of different final demands on the carbon emissions of industrial sector indicated that the increase in carbon emission arising from international and interprovincial trades is mainly concentrated in energy- and carbon-intensive industries. (4) Guangdong had to compromise a certain amount of carbon emissions during the development of its export-oriented economy because of industry transfer arising from the economic globalization, thereby pointing to the existence of the "carbon leakage" problem. At the same time, interprovincial export and import resulted in Guangdong transferring a part of its carbon emissions to other provinces, thereby leading to the occurrence of "carbon transfer."

  16. Direct observation of 0.57 eV trap-related RF output power reduction in AlGaN/GaN high electron mobility transistors

    Science.gov (United States)

    Arehart, A. R.; Sasikumar, A.; Rajan, S.; Via, G. D.; Poling, B.; Winningham, B.; Heller, E. R.; Brown, D.; Pei, Y.; Recht, F.; Mishra, U. K.; Ringel, S. A.

    2013-02-01

    This paper reports direct evidence for trap-related RF output power loss in GaN high electron mobility transistors (HEMTs) grown by metal organic chemical vapor deposition (MOCVD) through increased concentration of a specific electron trap at EC-0.57 eV that is located in the drain access region, as a function of accelerated life testing (ALT). The trap is detected by constant drain current deep level transient spectroscopy (CID-DLTS) and the CID-DLTS thermal emission time constant precisely matches the measured drain lag. Both drain lag and CID-DLTS measurements show this state to already exist in pre-stressed devices, which coupled with its strong increase in concentration as a function of stress in the absence of significant increases in concentrations of other detected traps, imply its role in causing degradation, in particular knee walkout. This study reveals EC-0.57 eV trap concentration tracks degradation induced by ALT for MOCVD-grown HEMTs supplied by several commercial and university sources. The results suggest this defect has a common source and may be a key degradation pathway in AlGaN/GaN HEMTs and/or an indicator to predict device lifetime.

  17. Preoperative unintended weight loss and low body mass index in relation to complications and length of stay after cardiac surgery

    NARCIS (Netherlands)

    van Venrooij, Lenny M. W.; de Vos, Rien; Borgmeijer-Hoelen, Mieke M. M. J.; Haaring, Cees; de Mol, Bas A. J. M.

    Background: Several studies reported increased adverse outcomes after cardiac surgery in patients with low body mass index (BMI; in kg/m(2)). Little is known yet, however, about the effect of preoperative unintended weight loss (UWL) in cardiac surgery patients. Objective: We explored the prevalence

  18. Preoperative unintended weight loss and low body mass index in relation to complications and length of stay after cardiac surgery

    NARCIS (Netherlands)

    van Venrooij, Lenny M. W.; de Vos, Rien; Borgmeijer-Hoelen, Mieke M. M. J.; Haaring, Cees; de Mol, Bas A. J. M.

    2008-01-01

    BACKGROUND: Several studies reported increased adverse outcomes after cardiac surgery in patients with low body mass index (BMI; in kg/m(2)). Little is known yet, however, about the effect of preoperative unintended weight loss (UWL) in cardiac surgery patients. OBJECTIVE: We explored the prevalence

  19. Adjuvant Hypofractionated Versus Conventional Whole Breast Radiation Therapy for Early-Stage Breast Cancer: Long-Term Hospital-Related Morbidity From Cardiac Causes

    International Nuclear Information System (INIS)

    Chan, Elisa K.; Woods, Ryan; McBride, Mary L.; Virani, Sean; Nichol, Alan; Speers, Caroline; Wai, Elaine S.; Tyldesley, Scott

    2014-01-01

    Purpose: The risk of cardiac injury with hypofractionated whole-breast/chest wall radiation therapy (HF-WBI) compared with conventional whole-breast/chest wall radiation therapy (CF-WBI) in women with left-sided breast cancer remains a concern. The purpose of this study was to determine if there is an increase in hospital-related morbidity from cardiac causes with HF-WBI relative to CF-WBI. Methods and Materials: Between 1990 and 1998, 5334 women ≤80 years of age with early-stage breast cancer were treated with postoperative radiation therapy to the breast or chest wall alone. A population-based database recorded baseline patient, tumor, and treatment factors. Hospital administrative records identified baseline cardiac risk factors and other comorbidities. Factors between radiation therapy groups were balanced using a propensity-score model. The first event of a hospital admission for cardiac causes after radiation therapy was determined from hospitalization records. Ten- and 15-year cumulative hospital-related cardiac morbidity after radiation therapy was estimated for left- and right-sided cases using a competing risk approach. Results: The median follow-up was 13.2 years. For left-sided cases, 485 women were treated with CF-WBI, and 2221 women were treated with HF-WBI. Mastectomy was more common in the HF-WBI group, whereas boost was more common in the CF-WBI group. The CF-WBI group had a higher prevalence of diabetes. The 15-year cumulative hospital-related morbidity from cardiac causes (95% confidence interval) was not different between the 2 radiation therapy regimens after propensity-score adjustment: 21% (19-22) with HF-WBI and 21% (17-25) with CF-WBI (P=.93). For right-sided cases, the 15-year cumulative hospital-related morbidity from cardiac causes was also similar between the radiation therapy groups (P=.76). Conclusions: There is no difference in morbidity leading to hospitalization from cardiac causes among women with left-sided early-stage breast

  20. Adjuvant Hypofractionated Versus Conventional Whole Breast Radiation Therapy for Early-Stage Breast Cancer: Long-Term Hospital-Related Morbidity From Cardiac Causes

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Elisa K. [Department of Oncology, Saint John Regional Hospital, Saint John (Canada); Woods, Ryan; McBride, Mary L. [Cancer Control Research Department, BC Cancer Agency, Vancouver (Canada); Virani, Sean [Division of Cardiology, University of British Columbia, Vancouver (Canada); Nichol, Alan [Radiation Therapy Program, BC Cancer Agency, Vancouver (Canada); Speers, Caroline [Breast Cancer Outcomes Unit, BC Cancer Agency, Vancouver (Canada); Wai, Elaine S. [Radiation Therapy Program, BC Cancer Agency, Vancouver (Canada); Tyldesley, Scott, E-mail: styldesl@bccancer.bc.ca [Radiation Therapy Program, BC Cancer Agency, Vancouver (Canada)

    2014-03-15

    Purpose: The risk of cardiac injury with hypofractionated whole-breast/chest wall radiation therapy (HF-WBI) compared with conventional whole-breast/chest wall radiation therapy (CF-WBI) in women with left-sided breast cancer remains a concern. The purpose of this study was to determine if there is an increase in hospital-related morbidity from cardiac causes with HF-WBI relative to CF-WBI. Methods and Materials: Between 1990 and 1998, 5334 women ≤80 years of age with early-stage breast cancer were treated with postoperative radiation therapy to the breast or chest wall alone. A population-based database recorded baseline patient, tumor, and treatment factors. Hospital administrative records identified baseline cardiac risk factors and other comorbidities. Factors between radiation therapy groups were balanced using a propensity-score model. The first event of a hospital admission for cardiac causes after radiation therapy was determined from hospitalization records. Ten- and 15-year cumulative hospital-related cardiac morbidity after radiation therapy was estimated for left- and right-sided cases using a competing risk approach. Results: The median follow-up was 13.2 years. For left-sided cases, 485 women were treated with CF-WBI, and 2221 women were treated with HF-WBI. Mastectomy was more common in the HF-WBI group, whereas boost was more common in the CF-WBI group. The CF-WBI group had a higher prevalence of diabetes. The 15-year cumulative hospital-related morbidity from cardiac causes (95% confidence interval) was not different between the 2 radiation therapy regimens after propensity-score adjustment: 21% (19-22) with HF-WBI and 21% (17-25) with CF-WBI (P=.93). For right-sided cases, the 15-year cumulative hospital-related morbidity from cardiac causes was also similar between the radiation therapy groups (P=.76). Conclusions: There is no difference in morbidity leading to hospitalization from cardiac causes among women with left-sided early-stage breast

  1. A cardiac-specific health-related quality of life module for young adults with congenital heart disease: development and validation

    NARCIS (Netherlands)

    Kamphuis, M.; Zwinderman, K.A.H.; Vogels, T.; Vliegen, H.W.; Kamphuis, R.P.; Ottenkamp, J.; Verloove-Vanhorick, S.P.; Bruil, J.

    2004-01-01

    This study represents the development and validation of a cardiac-specific module of the generic health-related quality of life (HRQoL) instrument, the TAAQOL (TNO/AZL Adult Quality Of Life), for young adults with congenital heart disease (CHD). Items were selected based on literature, an

  2. Validation of the concept Risk for Decreased Cardiac Output Validación del concepto riesgo de débito cardiaco disminuido Validação do conceito risco de débito cardíaco diminuído

    Directory of Open Access Journals (Sweden)

    Eduarda Ribeiro dos Santos

    2013-02-01

    Full Text Available OBJECTIVES: to validate the concept "risk for decreased cardiac output". METHOD: Six of the eight steps suggested in the technique developed by Walker & Avant were adopted to analyze the concept of the phenomenon under study and the proposal made by Hoskins was used for content validation, taking into account agreement achieved among five experts. RESULTS: the concept "decreased cardiac output" was found in the nursing and medical fields and refers to the heart's pumping capacity while the concept "risk" is found in a large number of disciplines. In regard to the defining attributes, "impaired pumping capacity" was the main attribute of decreased cardiac output and "probability" was the main attribute of risk. The uses and defining attributes of the concepts "decreased cardiac output" and "risk" were analyzed as well as their antecedent and consequent events in order to establish the definition of "risk for decreased cardiac output", which was validated by 100% of the experts. CONCLUSION: The obtained data indicate that the risk for decreased cardiac output phenomenon can be a nursing diagnosis and refining it can contribute to the advancement of nursing classifications in this context.OBJETIVO: Validar el concepto riesgo del débito cardíaco disminuido. MÉTODO: Fue adoptada la técnica de Walker & Avant para analizar la definición del fenómeno enfocado, utilizando seis de las ocho etapas sugeridas y la propuesta de Hoskins para validar el contenido, considerándose la conformidad entre cinco expertos. RESULTADOS: el concepto de debito cardíaco disminuido se encuentra en las áreas enfermería y médica y su atención se centra en la capacidad de bombeo del corazón. Sin embargo, el concepto de riesgo es presente en un gran número de áreas. Las características definitorias de la disminución del gasto cardíaco mostraron como principal atributo deficiencia de la bomba cardiaca y, para el riesgo, el atributo de probabilidad. Analizados

  3. Cardiac rehabilitation

    Science.gov (United States)

    ... rehab; Heart failure - cardiac rehab References Anderson L, Taylor RS. Cardiac rehabilitation for people with heart disease: ... of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed ...

  4. Prediction of drug-related cardiac adverse effects in humans--A: creation of a database of effects and identification of factors affecting their occurrence.

    Science.gov (United States)

    Matthews, Edwin J; Frid, Anna A

    2010-04-01

    This is the first of two reports that describes the compilation of a database of drug-related cardiac adverse effects (AEs) that was used to construct quantitative structure-activity relationship (QSAR) models to predict these AEs, to identify properties of pharmaceuticals correlated with the AEs, and to identify plausible mechanisms of action (MOAs) causing the AEs. This database of 396,985 cardiac AE reports was linked to 1632 approved drugs and their chemical structures, 1851 clinical indications (CIs), 997 therapeutic targets (TTs), 432 pharmacological MOAs, and 21,180 affinity coefficients (ACs) for the MOA receptors. AEs were obtained from the Food and Drug Administration's (FDA's) Spontaneous Reporting System (SRS) and Adverse Event Reporting System (AERS) and publicly available medical literature. Drug TTs were obtained from Integrity; drug MOAs and ACs were predicted by BioEpisteme. Significant cardiac AEs and patient exposures were estimated based on the proportional reporting ratios (PRRs) for each drug and each AE endpoint as a percentage of the total AEs. Cardiac AE endpoints were bundled based on toxicological mechanism and concordance of drug-related findings. Results revealed that significant cardiac AEs formed 9 clusters affecting Purkinje nerve fibers (arrhythmia, bradycardia, conduction disorder, electrocardiogram, palpitations, QT prolongation, rate rhythm composite, tachycardia, and Torsades de pointes), and 5 clusters affecting the heart muscle (coronary artery disorders, heart failure, myocardial disorders, myocardial infarction, and valve disorders). Based on the observation that each drug had one TT and up to 9 off-target MOAs, cardiac AEs were highly correlated with drugs affecting cardiovascular and cardioneurological functions and certain MOAs (e.g., alpha- and beta-adeno, dopamine, and hydroxytryptomine receptors). Copyright 2010. Published by Elsevier Inc.

  5. Input-output supervisor

    International Nuclear Information System (INIS)

    Dupuy, R.

    1970-01-01

    The input-output supervisor is the program which monitors the flow of informations between core storage and peripheral equipments of a computer. This work is composed of three parts: 1 - Study of a generalized input-output supervisor. With sample modifications it looks like most of input-output supervisors which are running now on computers. 2 - Application of this theory on a magnetic drum. 3 - Hardware requirement for time-sharing. (author) [fr

  6. Pediatric cardiac postoperative care

    Directory of Open Access Journals (Sweden)

    Auler Jr. José Otávio Costa

    2002-01-01

    Full Text Available The Heart Institute of the University of São Paulo, Medical School is a referral center for the treatment of congenital heart diseases of neonates and infants. In the recent years, the excellent surgical results obtained in our institution may be in part due to modern anesthetic care and to postoperative care based on well-structured protocols. The purpose of this article is to review unique aspects of neonate cardiovascular physiology, the impact of extracorporeal circulation on postoperative evolution, and the prescription for pharmacological support of acute cardiac dysfunction based on our cardiac unit protocols. The main causes of low cardiac output after surgical correction of heart congenital disease are reviewed, and methods of treatment and support are proposed as derived from the relevant literature and our protocols.

  7. Sci—Fri AM: Mountain — 01: Validation of a new formulism and the related correction factors on output factor determination for small photon fields

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yizhen; Younge, Kelly; Nielsen, Michelle; Mutanga, Theodore [Peel Regional Cancer Center, Trillium Health Partners, Mississauga, ON (Canada); Cui, Congwu [Peel Regional Cancer Center, Trillium Health Partners, Mississauga, ON (Canada); Department of Radiation Oncology, University of Toronto, Toronto, ON (Canada); Das, Indra J. [Radiation Oncology Dept., Indiana University- School of Medicine, Indianapolis, IN (United States)

    2014-08-15

    Small field dosimetry measurements including output factors are difficult due to lack of charged-particle equilibrium, occlusion of the radiation source, the finite size of detectors, and non-water equivalence of detector components. With available detectors significant variations could be measured that will lead to incorrect delivered dose to patients. IAEA/AAPM have provided a framework and formulation to correct the detector response in small photon fields. Monte Carlo derived correction factors for some commonly used small field detectors are now available, however validation has not been performed prior to this study. An Exradin A16 chamber, EDGE detector and SFD detector were used to perform the output factor measurement for a series of conical fields (5–30mm) on a Varian iX linear accelerator. Discrepancies up to 20%, 10% and 6% were observed for 5, 7.5 and 10 mm cones between the initial output factors measured by the EDGE detector and the A16 ion chamber, while the discrepancies for the conical fields larger than 10 mm were less than 4%. After the application of the correction, the output factors agree well with each other to within 1%. Caution is needed when determining the output factors for small photon fields, especially for fields 10 mm in diameter or smaller. More than one type of detector should be used, each with proper corrections applied to the measurement results. It is concluded that with the application of correction factors to appropriately chosen detectors, output can be measured accurately for small fields.

  8. Reporting of coronary artery calcification on chest CT studies in breast cancer patients at high risk of cancer therapy related cardiac events

    Directory of Open Access Journals (Sweden)

    William J. Phillips

    2018-03-01

    Full Text Available Background: The identification of coronary artery calcification (CAC detected coincidentally on chest CT exams could assist in cardiovascular risk assessment but may not be reported consistently on clinical studies. Cardiovascular risk factor stratification is important to predict short term cardiac events during cancer therapy and long term cardiac event free survival in cancer patients. We sought to determine the prevalence of CAC and clinical reporting rates in a cohort of cancer patients at high risk of cancer therapy related cardiac events. Methods: 408 Breast cancer patients who were referred to a cardiac oncology clinic were screened. Inclusion criteria included having had a CT chest and the absence of known coronary disease. Among those screened 263 patients were included in the study. Results: CAC was identified in 70 patients (26%. CAC was reported in 18% of studies. The reporting rates of CAC increased with the extent of coronary calcification (p < 0.01 and increased during the period of the study (p < 0.05. Conclusions: CAC was commonly detected on chest CT studies in this observational study of breast cancer patients at high risk of cardiac oncology events. The presence of CAC was often not reported clinically but reporting rates have increased over time. Recent SCCT/STR guidelines recommend reporting the presence of CAC on routine chest CT scans in recognition of the importance of CAC as a predictor of cardiovascular events. Reporting of CAC on chest CTs may help to further risk stratify breast cancer patients and improve cardiovascular outcomes in this vulnerable population. Keywords: Cardiac oncology, Coronary calcification and chest CT

  9. Cardiac responses predict decisions: an investigation of the relation between orienting response and decisions in the ultimatum game.

    Science.gov (United States)

    Osumi, Takahiro; Ohira, Hideki

    2009-10-01

    Emotion-based behaviors in humans cannot be fully explained by economic rationality. Particularly, in the ultimatum game, which incorporates conflict between self-interest and fairness, negative emotions evoked by an unfair offer seem to promote an economically irrational decision. In accordance with this suggestion, the previous studies have reported that physiological arousal is associated with rejecting unfair offers. In the present study, we investigated electrocardiogram and electrodermal activities in individuals which received fair, advantageously unfair, and disadvantageously unfair offers to specify the relations of the orienting and the defensive responses with these offers and with the decisions to accept and reject them. The results indicated that when an offer that would be rejected was presented, heart rate initially decelerated more than when an offer that would be accepted was presented. Additionally, there was a linear relationship between the deceleration and unfairness of offers. On the other hand, such different patterns were not seen in late cardiac acceleration or electrodermal response. The results suggest that because of perception of disadvantage and unpleasantness in a social context, the orienting response is evoked when an offer will be rejected. In addition, these results are discussed regarding the effect of the autonomic activity in decision-making.

  10. Sudden cardiac death

    Directory of Open Access Journals (Sweden)

    Neeraj Parakh

    2015-01-01

    Full Text Available Sudden cardiac death is one of the most common cause of mortality worldwide. Despite significant advances in the medical science, there is little improvement in the sudden cardiac death related mortality. Coronary artery disease is the most common etiology behind sudden cardiac death, in the above 40 years population. Even in the apparently healthy population, there is a small percentage of patients dying from sudden cardiac death. Given the large denominator, this small percentage contributes to the largest burden of sudden cardiac death. Identification of this at risk group among the apparently healthy individual is a great challenge for the medical fraternity. This article looks into the causes and methods of preventing SCD and at some of the Indian data. Details of Brugada syndrome, Long QT syndrome, Genetics of SCD are discussed. Recent guidelines on many of these causes are summarised.

  11. Attention to affective pictures in closed head injury: event-related brain potentials and cardiac responses.

    Science.gov (United States)

    Solbakk, Anne-Kristin; Reinvang, Ivar; Svebak, Sven; Nielsen, Christopher S; Sundet, Kjetil

    2005-02-01

    We examined whether closed head injury patients show altered patterns of selective attention to stimulus categories that naturally evoke differential responses in healthy people. Self-reported rating and electrophysiological (event-related potentials [ERPs], heart rate [HR]) responses to affective pictures were studied in patients with mild head injury (n = 20; CT/MRI negative), in patients with predominantly frontal brain lesions (n = 12; CT/MRI confirmed), and in healthy controls (n = 20). Affective valence similarly modulated HR and ERP responses in all groups, but group differences occurred that were independent of picture valence. The attenuation of P3-slow wave amplitudes in the mild head injury group indicates a reduction in the engagement of attentional resources to the task. In contrast, the general enhancement of ERP amplitudes at occipital sites in the group with primarily frontal brain injury may reflect disinhibition of input at sensory receptive areas, possibly due to a deficit in top-down modulation performed by anterior control systems.

  12. Output factors and scatter ratios

    Energy Technology Data Exchange (ETDEWEB)

    Shrivastava, P N; Summers, R E; Samulski, T V; Baird, L C [Allegheny General Hospital, Pittsburgh, PA (USA); Ahuja, A S; Dubuque, G L; Hendee, W R; Chhabra, A S

    1979-07-01

    Reference is made to a previous publication on output factors and scatter ratios for radiotherapy units in which it was suggested that the output factor should be included in the definitions of scatter-air ratio and tissue-maximum ratio. In the present correspondence from other authors and from the authors of the previous publication, the original definitions and the proposed changes are discussed. Radiation scatter from source and collimator degradation of beam energy and calculation of dose in tissue are considered in relation to the objective of accurate dosimetry.

  13. Self-efficacy and overprotection are related to quality of life, psychological well-being and self-management in cardiac patients.

    Science.gov (United States)

    Joekes, Katherine; Van Elderen, Thérèse; Schreurs, Karlein

    2007-01-01

    This repeated-measures study explores how self-efficacy and overprotection relate to psychological well-being, health-related quality of life and self-management. Eighty-two cardiac patients, suffering from congestive heart failure (CHF) or myocardial infarction (MI), completed questionnaires at T1 and three months later. Perceived overprotection is associated with concurrent levels of anxiety and depression, and lowered quality of life. Self-efficacy is related to psychological well-being in both patient groups, but only associated with quality of life in CHF patients. In addition, self-efficacy predicts MI patients' self-management behaviours in the medium term. Findings have implications for cardiac rehabilitation, where attention may usefully be focused on enhancing self-efficacy and dealing with issues of support and overprotection by the partner.

  14. Donor age is a predictor of early low output after heart transplantation.

    Science.gov (United States)

    Fujino, Takeo; Kinugawa, Koichiro; Nitta, Daisuke; Imamura, Teruhiko; Maki, Hisataka; Amiya, Eisuke; Hatano, Masaru; Kimura, Mitsutoshi; Kinoshita, Osamu; Nawata, Kan; Komuro, Issei; Ono, Minoru

    2016-05-01

    Using hearts from marginal donors could be related to increased risk of primary graft dysfunction and poor long-term survival. However, factors associated with delayed myocardial recovery after heart transplantation (HTx) remain unknown. We sought to clarify risk factors that predict early low output after HTx, and investigated whether early low output affects mid-term graft dysfunction. We retrospectively analyzed patients who had undergone HTx at The University of Tokyo Hospital. We defined early low output patients as those whose cardiac index (CI) was early low output group, and the others into early preserved output group. We performed univariable logistic analysis and found that donor age was the only significant factor that predicted early low output (odds ratio 1.107, 95% confidence interval 1.034-1.210, p=0.002). CI of early low output patients gradually increased and it caught up with that of early preserved output patients at 2 weeks after HTx (2.4±0.6 L/min/m(2) in early low output group vs 2.5±0.5 L/min/m(2) in early preserved output group, p=0.684). Plasma B-type natriuretic peptide concentration of early low output patients was higher (1118.5±1250.2 pg/ml vs 526.4±399.5 pg/ml; p=0.033) at 1 week, 703.6±518.4 pg/ml vs 464.6±509.0 pg/ml (p=0.033) at 2 weeks, and 387.7±231.9 pg/ml vs 249.4±209.5 pg/ml (p=0.010) at 4 weeks after HTx, and it came down to that of early preserved output patients at 12 weeks after HTx. Donor age was a predictor of early low output after HTx. We should be careful after HTx from old donors. However, hemodynamic parameters of early low output patients gradually caught up with those of early preserved output patients. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Meta-Analysis of the Relation of Baseline Right Ventricular Function to Response to Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Sharma, Abhishek; Bax, Jerome J; Vallakati, Ajay; Goel, Sunny; Lavie, Carl J; Kassotis, John; Mukherjee, Debabrata; Einstein, Andrew; Warrier, Nikhil; Lazar, Jason M

    2016-04-15

    Right ventricular (RV) dysfunction has been associated with adverse clinical outcomes in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) improves left ventricular (LV) size and function in patients with markedly abnormal electrocardiogram QRS duration. However, relation of baseline RV function with response to CRT has not been well described. In this study, we aim to investigate the relation of baseline RV function with response to CRT as assessed by change in LV ejection fraction (EF). A systematic search of studies published from 1966 to May 31, 2015 was conducted using PubMed, CINAHL, Cochrane CENTRAL, and the Web of Science databases. Studies were included if they have reported (1) parameters of baseline RV function (tricuspid annular plane systolic excursion [TAPSE] or RVEF or RV basal strain or RV fractional area change [FAC]) and (2) LVEF before and after CRT. Random-effects metaregression was used to evaluate the effect of baseline RV function parameters and change in LVEF. Sixteen studies (n = 1,764) were selected for final analysis. Random-effects metaregression analysis showed no significant association between the magnitude of the difference in EF before and after CRT with baseline TAPSE (β = 0.005, p = 0.989); baseline RVEF (β = 0.270, p = 0.493); baseline RVFAC (β = -0.367, p = 0.06); baseline basal strain (β = -0.342, p = 0.462) after a mean follow-up period of 10.5 months. In conclusion, baseline RV function as assessed by TAPSE, FAC, basal strain, or RVEF does not determine response to CRT as assessed by change in LVEF. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Clinical features and prognostic implications of familial hypertrophic cardiomyopathy related to the cardiac myosin-binding protein C gene.

    Science.gov (United States)

    Charron, P; Dubourg, O; Desnos, M; Bennaceur, M; Carrier, L; Camproux, A C; Isnard, R; Hagege, A; Langlard, J M; Bonne, G; Richard, P; Hainque, B; Bouhour, J B; Schwartz, K; Komajda, M

    1998-06-09

    Little information is available on phenotype-genotype correlations in familial hypertrophic cardiomyopathy that are related to the cardiac myosin binding protein C (MYBPC3) gene. The aim of this study was to perform this type of analysis. We studied 76 genetically affected subjects from nine families with seven recently identified mutations (SASint20, SDSint7, SDSint23, branch point int23, Glu542Gln, a deletion in exon 25, and a duplication/deletion in exon 33) in the MYBPC3 gene. Detailed clinical, ECG, and echocardiographic parameters were analyzed. An intergene analysis was performed by comparing the MYBPC3 group to seven mutations in the beta-myosin heavy-chain gene (beta-MHC) group (n=52). There was no significant phenotypic difference among the different mutations in the MYBPC3 gene. However, in the MYBPC3 group compared with the beta-MHC group, (1) prognosis was significantly better (P<0.0001), and no deaths occurred before the age of 40 years; (2) the age at onset of symptoms was delayed (41+/-19 versus 35+/-17 years, P<0.002); and (3) before 30 years of age, the phenotype was particularly mild because penetrance was low (41% versus 62%), maximal wall thicknesses lower (12+/-4 versus 16+/-7 mm, P<0.03), and abnormal T waves less frequent (9% versus 45%, P<0.02). These results are consistent with specific clinical features related to the MYBPC3 gene: onset of the disease appears delayed and the prognosis is better than that associated with the beta-MHC gene. These findings could be particularly important for the purpose of clinical management and genetic counseling in familial hypertrophic cardiomyopathy.

  17. Are there meaningful longitudinal changes in health related quality of life--SF36, in cardiac rehabilitation patients?

    LENUS (Irish Health Repository)

    McKee, Gabrielle

    2012-02-01

    BACKGROUND: This study aimed to observe changes in quality of life and minimal clinical important differences of quality of life over time in cardiac rehabilitation patients and to compare these with published normal data. METHODS: In this non-randomised study, SF36 questionnaires were completed by 187 patients recruited to a Phase III cardiac rehabilitation multidisciplinary outpatient programme. Data was collected at beginning, end and six months after Phase III cardiac rehabilitation programme. RESULTS: There were significant improvements in physical functioning, role limitation due to physical function, pain and general health perception scales, over the above time frame, from both a statistically and a mean clinical important difference point of view. These improvements occurred mainly during the cardiac rehabilitation programme phase. CONCLUSIONS: These improvements meant that patients six months post-cardiac rehabilitation were only 5% below the quality of life for an aged matched normal group. However patients still had significant deficits in physical role and emotional role limitations. Suitable measurement of quality of life on an individual basis, supported by normal values is needed. This would facilitate the identification of shortfalls in patient quality of life and the subsequent tailoring of care to address these individualised patient needs.

  18. WRF Model Output

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains WRF model output. There are three months of data: July 2012, July 2013, and January 2013. For each month, several simulations were made: A...

  19. VMS forms Output Tables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These output tables contain parsed and format validated data from the various VMS forms that are sent from any given vessel, while at sea, from the VMS devices on...

  20. Governmentally amplified output volatility

    Science.gov (United States)

    Funashima, Yoshito

    2016-11-01

    Predominant government behavior is decomposed by frequency into several periodic components: updating cycles of infrastructure, Kuznets cycles, fiscal policy over business cycles, and election cycles. Little is known, however, about the theoretical impact of such cyclical behavior in public finance on output fluctuations. Based on a standard neoclassical growth model, this study intends to examine the frequency at which public investment cycles are relevant to output fluctuations. We find an inverted U-shaped relationship between output volatility and length of cycle in public investment. This implies that periodic behavior in public investment at a certain frequency range can cause aggravated output resonance. Moreover, we present an empirical analysis to test the theoretical implication, using the U.S. data in the period from 1968 to 2015. The empirical results suggest that such resonance phenomena change from low to high frequency.

  1. CMAQ Model Output

    Data.gov (United States)

    U.S. Environmental Protection Agency — CMAQ and CMAQ-VBS model output. This dataset is not publicly accessible because: Files too large. It can be accessed through the following means: via EPA's NCC tape...

  2. Cardiac ventriculography

    International Nuclear Information System (INIS)

    Hillis, L.D.; Grossman, W.

    1986-01-01

    Cardiac ventriculography has been used extensively to define the anatomy of the ventricles and related structures in patients with congenital, valvular, coronary, and cardiomyopathic heart disease. Specifically, left ventriculography may provide valuable information about global and segmental left ventricular function, mitral valvular incompetence, and the presence, location, and severity of a number of other abnormalities, including ventricular septal defect and hypertrophic cardiomyopathy. As a result, it should be a routine part of catheterization in patients being evaluated for coronary artery disease, aortic or mitral valvular disease, unexplained left ventricular failure, or congenital heart disease. Similarly, right ventriculography may provide information about global and segmental right ventricular function and can be especially helpful in patients with congenital heart disease

  3. Out-of-hospital cardiac arrest: Probability of bystander defibrillation relative to distance to nearest automated external defibrillator.

    Science.gov (United States)

    Sondergaard, Kathrine B; Hansen, Steen Moller; Pallisgaard, Jannik L; Gerds, Thomas Alexander; Wissenberg, Mads; Karlsson, Lena; Lippert, Freddy K; Gislason, Gunnar H; Torp-Pedersen, Christian; Folke, Fredrik

    2018-03-01

    Despite wide dissemination of automated external defibrillators (AEDs), bystander defibrillation rates remain low. We aimed to investigate how route distance to the nearest accessible AED was associated with probability of bystander defibrillation in public and residential locations. We used data from the nationwide Danish Cardiac Arrest Registry and the Danish AED Network to identify out-of-hospital cardiac arrests and route distances to nearest accessible registered AED during 2008-2013. The association between route distance and bystander defibrillation was described using restricted cubic spline logistic regression. We included 6971 out-of-hospital cardiac arrest cases. The proportion of arrests according to distance in meters (≤100, 101-200, >200) to the nearest accessible AED was: 4.6% (n=320), 5.3% (n=370), and 90.1% (n=6281), respectively. For cardiac arrests in public locations, the probability of bystander defibrillation at 0, 100 and 200m from the nearest AED was 35.7% (95% confidence interval 28.0%-43.5%), 21.3% (95% confidence interval 17.4%-25.2%), and 13.7% (95% confidence interval 10.1%-16.8%), respectively. The corresponding numbers for cardiac arrests in residential locations were 7.0% (95% confidence interval -2.1%-16.1%), 1.5% (95% confidence interval 0.002%-2.8%), and 0.9% (95% confidence interval 0.0005%-1.7%), respectively. In public locations, the probability of bystander defibrillation decreased rapidly within the first 100m route distance from cardiac arrest to nearest accessible AED whereas the probability of bystander defibrillation was low for all distances in residential areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Relation between the Disability of the Arm, Shoulder and Hand Score and Muscle Strength in Post-Cardiac Surgery Patients.

    Science.gov (United States)

    Izawa, Kazuhiro P; Kasahara, Yusuke; Hiraki, Koji; Hirano, Yasuyuki; Watanabe, Satoshi

    2017-11-27

    Background: The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire is a valid and reliable patient-reported outcome measure. DASH can be assessed by self-reported upper extremity disability and symptoms. We aimed to examine the relationship between the physiological outcome of muscle strength and the DASH score after cardiac surgery. Methods: This cross-sectional study assessed 50 consecutive cardiac patients that were undergoing cardiac surgery. Physiological outcomes of handgrip strength and knee extensor muscle strength and the DASH score were measured at one month after cardiac surgery and were assessed. Results were analyzed using Spearman correlation coefficients. Results: The final analysis comprised 43 patients (men: 32, women: 11; age: 62.1 ± 9.1 years; body mass index: 22.1 ± 4.7 kg/m²; left ventricular ejection fraction: 53.5 ± 13.7%). Respective handgrip strength, knee extensor muscle strength, and DASH score were 27.4 ± 8.3 kgf, 1.6 ± 0.4 Nm/kg, and 13.3 ± 12.3, respectively. The DASH score correlated negatively with handgrip strength ( r = -0.38, p = 0.01) and with knee extensor muscle strength ( r = -0.32, p = 0.04). Conclusion: Physiological outcomes of both handgrip strength and knee extensor muscle strength correlated negatively with the DASH score. The DASH score appears to be a valuable tool with which to assess cardiac patients with poor physiological outcomes, particularly handgrip strength as a measure of upper extremity function, which is probably easier to follow over time than lower extremity function after patients complete cardiac rehabilitation.

  5. Relation between the Disability of the Arm, Shoulder and Hand Score and Muscle Strength in Post-Cardiac Surgery Patients

    Directory of Open Access Journals (Sweden)

    Kazuhiro P. Izawa

    2017-11-01

    Full Text Available Background: The Disabilities of the Arm, Shoulder, and Hand (DASH questionnaire is a valid and reliable patient-reported outcome measure. DASH can be assessed by self-reported upper extremity disability and symptoms. We aimed to examine the relationship between the physiological outcome of muscle strength and the DASH score after cardiac surgery. Methods: This cross-sectional study assessed 50 consecutive cardiac patients that were undergoing cardiac surgery. Physiological outcomes of handgrip strength and knee extensor muscle strength and the DASH score were measured at one month after cardiac surgery and were assessed. Results were analyzed using Spearman correlation coefficients. Results: The final analysis comprised 43 patients (men: 32, women: 11; age: 62.1 ± 9.1 years; body mass index: 22.1 ± 4.7 kg/m2; left ventricular ejection fraction: 53.5 ± 13.7%. Respective handgrip strength, knee extensor muscle strength, and DASH score were 27.4 ± 8.3 kgf, 1.6 ± 0.4 Nm/kg, and 13.3 ± 12.3, respectively. The DASH score correlated negatively with handgrip strength (r = −0.38, p = 0.01 and with knee extensor muscle strength (r = −0.32, p = 0.04. Conclusion: Physiological outcomes of both handgrip strength and knee extensor muscle strength correlated negatively with the DASH score. The DASH score appears to be a valuable tool with which to assess cardiac patients with poor physiological outcomes, particularly handgrip strength as a measure of upper extremity function, which is probably easier to follow over time than lower extremity function after patients complete cardiac rehabilitation.

  6. Comprehensive cardiac rehabilitation

    DEFF Research Database (Denmark)

    Kruse, Marie; Hochstrasser, Stefan; Zwisler, Ann-Dorthe O

    2006-01-01

    OBJECTIVES: The costs of comprehensive cardiac rehabilitation are established and compared to the corresponding costs of usual care. The effect on health-related quality of life is analyzed. METHODS: An unprecedented and very detailed cost assessment was carried out, as no guidelines existed...... and may be as high as euro 1.877. CONCLUSIONS: Comprehensive cardiac rehabilitation is more costly than usual care, and the higher costs are not outweighed by a quality of life gain. Comprehensive cardiac rehabilitation is, therefore, not cost-effective....

  7. Dual energy cardiac CT.

    Science.gov (United States)

    Carrascosa, Patricia; Deviggiano, Alejandro; Rodriguez-Granillo, Gastón

    2017-06-01

    Conventional single energy CT suffers from technical limitations related to the polychromatic nature of X-rays. Dual energy cardiac CT (DECT) shows promise to attenuate and even overcome some of these limitations, and might broaden the scope of patients eligible for cardiac CT towards the inclusion of higher risk patients. This might be achieved as a result of both safety (contrast reduction) and physiopathological (myocardial perfusion and characterization) issues. In this article, we will review the main clinical cardiac applications of DECT, that can be summarized in two core aspects: coronary artery evaluation, and myocardial evaluation.

  8. Task-related changes in degree centrality and local coherence of the posterior cingulate cortex after major cardiac surgery in older adults.

    Science.gov (United States)

    Browndyke, Jeffrey N; Berger, Miles; Smith, Patrick J; Harshbarger, Todd B; Monge, Zachary A; Panchal, Viral; Bisanar, Tiffany L; Glower, Donald D; Alexander, John H; Cabeza, Roberto; Welsh-Bohmer, Kathleen; Newman, Mark F; Mathew, Joseph P

    2018-02-01

    Older adults often display postoperative cognitive decline (POCD) after surgery, yet it is unclear to what extent functional connectivity (FC) alterations may underlie these deficits. We examined for postoperative voxel-wise FC changes in response to increased working memory load demands in cardiac surgery patients and nonsurgical controls. Older cardiac surgery patients (n = 25) completed a verbal N-back working memory task during MRI scanning and cognitive testing before and 6 weeks after surgery; nonsurgical controls with cardiac disease (n = 26) underwent these assessments at identical time intervals. We measured postoperative changes in degree centrality, the number of edges attached to a brain node, and local coherence, the temporal homogeneity of regional functional correlations, using voxel-wise graph theory-based FC metrics. Group × time differences were evaluated in these FC metrics associated with increased N-back working memory load (2-back > 1-back), using a two-stage partitioned variance, mixed ANCOVA. Cardiac surgery patients demonstrated postoperative working memory load-related degree centrality increases in the left dorsal posterior cingulate cortex (dPCC; p < .001, cluster p-FWE < .05). The dPCC also showed a postoperative increase in working memory load-associated local coherence (p < .001, cluster p-FWE < .05). dPCC degree centrality and local coherence increases were inversely associated with global cognitive change in surgery patients (p < .01), but not in controls. Cardiac surgery patients showed postoperative increases in working memory load-associated degree centrality and local coherence of the dPCC that were inversely associated with postoperative global cognitive outcomes and independent of perioperative cerebrovascular damage. © 2017 Wiley Periodicals, Inc.

  9. Surgical site infection after central venous catheter-related infection in cardiac surgery. Analysis of a cohort of 7557 patients.

    Science.gov (United States)

    Le Guillou, V; Tavolacci, M-P; Baste, J-M; Hubscher, C; Bedoit, E; Bessou, J-P; Litzler, P-Y

    2011-11-01

    The aim of this study was to establish the relationship between the occurrence of a surgical site infection (SSI) and the presence of a central venous catheter-related infection (CVCRI). The Department of Thoracic and Cardiovascular Surgery, University Hospital, Rouen, has carried out a prospective epidemiological survey of all nosocomial infections (pneumonia, SSI and CVCRI) since 1997. The study group included all consecutive patients who underwent cardiac surgery over a 10-year period from 1997 to 2007. A nested case-control study was conducted to identify the risk factors for SSI after CVCRI. Cases were patients with SSI after CVCRI and controls were randomized from patients who presented with CVCRI not followed by SSI. In total, 7557 patients were included and 133 SSIs (1.7%) were identified. The rate of superficial SSI was 0.7% [95% confidence interval (CI): 0.5-0.9] and of mediastinitis was 1.0% (95% CI: 0.8-1.2). Among the 133 cases of SSI, 12 (9.0%; 95% CI: 5.0-14.8) occurred after a CVCRI with identical micro-organisms. CVCRI [adjusted odds ratio (aOR): 5.2; 95% CI: 3.2-8.5], coronary artery bypass grafting (aOR: 2.9; 95% CI: 1.6-5.2), and obesity (aOR: 11.4; 95% CI: 1.0-130.1) were independent factors associated with SSI. The new finding of this study is that patients with CVCRI were 5.2 times more likely to develop SSI compared to patients without CVCRI. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  10. Positive affect moderates the effect of negative affect on cardiovascular disease-related hospitalizations and all-cause mortality after cardiac rehabilitation.

    Science.gov (United States)

    Meyer, Fiorenza Angela; von Känel, Roland; Saner, Hugo; Schmid, Jean-Paul; Stauber, Stefanie

    2015-10-01

    Little is known as to whether negative emotions adversely impact the prognosis of patients who undergo cardiac rehabilitation. We prospectively investigated the predictive value of state negative affect (NA) assessed at discharge from cardiac rehabilitation for prognosis and the moderating role of positive affect (PA) on the effect of NA on outcomes. A total of 564 cardiac patients (62.49 ± 11.51) completed a comprehensive three-month outpatient cardiac rehabilitation program, filling in the Global Mood Scale (GMS) at discharge. The combined endpoint was cardiovascular disease (CVD)-related hospitalizations plus all-cause mortality at follow-up. Cox regression models estimated the predictive value of NA, as well as the moderating influence of PA on outcomes. Survival models were adjusted for sociodemographic factors, traditional cardiovascular risk factors, and severity of disease. During a mean follow-up period of 3.4 years, 71 patients were hospitalized for a CVD-related event and 15 patients died. NA score (range 0-20) was a significant and independent predictor (hazard ratio (HR) 1.091, 95% confidence interval (CI) 1.012-1.175; p = 0.023) with a three-point higher level in NA increasing the relative risk by 9.1%. Furthermore, PA interacted significantly with NA (p < 0.001). The relative risk of poor prognosis with NA was increased in patients with low PA (p = 0.012) but remained unchanged in combination with high PA (p = 0.12). The combination of NA with low PA was particularly predictive of poor prognosis. Whether reduction of NA and increase of PA, particularly in those with high NA, improves outcome needs to be tested. © The European Society of Cardiology 2014.

  11. Débito cardíaco e fração de ejeção fetal por meio do spatio-temporal image correlation (STIC: comparação entre fetos masculinos e femininos Fetal cardiac output and ejection fraction by spatio-temporal image correlation (STIC: comparison between male and female fetuses

    Directory of Open Access Journals (Sweden)

    Christiane Simioni

    2012-06-01

    Full Text Available OBJETIVO: Comparar do débito cardíaco (DC e a fração de ejeção (FE do coração de fetos masculinos e femininos obtidos por meio da ultrassonografia tridimensional, utilizando o spatio-temporal image correlation (STIC. MÉTODOS: Realizou-se um estudo de corte transversal com 216 fetos normais, entre 20 a 34 semanas de gestação, sendo 108 masculinos e 108 femininos. Os volumes ventriculares no final da sístole e diástole foram obtidos por meio do STIC, sendo as avaliações volumétricas realizadas pelo virtual organ computer-aided analysis (VOCAL com rotação de 30º. Para o cálculo do DC utilizou-se a fórmula: DC= volume sistólico/frequência cardíaca fetal, enquanto que para a FE utilizou-se a fórmula: FE= volume sistólico/volume diastólico final. O DC (combinado, feminino e masculino e a FE (masculina e feminina foram comparadas utilizando-se o teste t não pareado e ANCOVA. Foram criados gráficos de dispersão com os percentis 5, 50 e 95. RESULTADOS: A média do DC combinado, DC direito, DC esquerdo, FE direita e FE esquerda, para feminino e masculino, foram 240,07 mL/min; 122,67 mL/min; 123,40 mL/min; 72,84%; 67,22%; 270,56 mL/min; 139,22 mL/min; 131,34 mL/min; 70,73% e 64,76%, respectivamente; sem diferença estatística (P> 0,05. CONCLUSÕES: O DC e a FE fetal obtidos por meio da ultrassonografia tridimensional (STIC não apresentaram diferença significativa em relação ao gênero.OBJECTIVE: To compare the cardiac output (CO and ejection fraction (EF of the heart of male and female fetuses obtained by 3D-ultrasonography using spatio-temporal image correlation (STIC. METHODS: We conducted a cross-sectional study with 216 normal fetuses, between 20 and 34 weeks of gestation, 108 male and 108 female. Ventricular volumes at the end of systole and diastole were obtained by STIC, and the volumetric assessments performed by the virtual organ computer-aided analysis (VOCAL rotated 30º. To calculate the DC used the formula

  12. Output Control Using Feedforward And Cascade Controllers

    Science.gov (United States)

    Seraji, Homayoun

    1990-01-01

    Report presents theoretical study of open-loop control elements in single-input, single-output linear system. Focus on output-control (servomechanism) problem, in which objective is to find control scheme that causes output to track certain command inputs and to reject certain disturbance inputs in steady state. Report closes with brief discussion of characteristics and relative merits of feedforward, cascade, and feedback controllers and combinations thereof.

  13. Awareness in cardiac anesthesia.

    LENUS (Irish Health Repository)

    Serfontein, Leon

    2010-02-01

    Cardiac surgery represents a sub-group of patients at significantly increased risk of intraoperative awareness. Relatively few recent publications have targeted the topic of awareness in this group. The aim of this review is to identify areas of awareness research that may equally be extrapolated to cardiac anesthesia in the attempt to increase understanding of the nature and significance of this scenario and how to reduce it.

  14. A multicentric study of disease-related stress, and perceived vulnerability, in parents of children with congenital cardiac disease

    NARCIS (Netherlands)

    Vrijmoet-Wiersma, C. M. Jantien; Ottenkamp, Jaap; van Roozendaal, Matty; Grootenhuis, Martha A.; Koopman, Hendrik M.

    2009-01-01

    Parents of children with congenitally malformed hearts can suffer from stress as a result of the medical condition of their child. In this cross-sectional study, we aimed to describe levels of parental stress, and perceived vulnerability, in parents of children who underwent major cardiac surgery,

  15. Galectin-3 levels relate in children to total body fat, abdominal fat, body fat distribution, and cardiac size.

    Science.gov (United States)

    Dencker, Magnus; Arvidsson, Daniel; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola

    2018-03-01

    Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8-11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3. What is Known: • Galectin-3 has been linked to obesity and been proposed to be a novel biomarker

  16. Oil output's changing fortunes

    International Nuclear Information System (INIS)

    Eldridge, D.

    1994-01-01

    The Petroleum Economist, previously the Petroleum Press Service, has been making annual surveys of output levels of petroleum in all the oil-producing countries since its founding in 1934. This article documents trends and changes in the major oil-producing countries output from 1934 until the present. This analysis is linked with the political and historical events accompanying these changes, notably the growth of Middle Eastern oil production, the North Sea finds and most recently, Iraq's invasion of Kuwait in 1990. (UK)

  17. Age-Related Differences in the Effect of Psychological Distress on Mortality: Type D Personality in Younger versus Older Patients with Cardiac Arrhythmias

    Directory of Open Access Journals (Sweden)

    Johan Denollet

    2013-01-01

    Full Text Available Background. Mixed findings in biobehavioral research on heart disease may partly be attributed to age-related differences in the prognostic value of psychological distress. This study sought to test the hypothesis that Type D (distressed personality contributes to an increased mortality risk following implantable cardioverter defibrillator (ICD treatment in younger patients but not in older patients. Methods. The Type D Scale (DS14 was used to assess general psychological distress in 455 younger (≤70 y,. Cardiac resynchronization therapy (CRT, but not Type D personality, was associated with increased mortality in older patients. Among younger patients, however, Type D personality was associated with an adjusted hazard ratio = 1.91 (95% CI 1.09–3.34 and 2.26 (95% CI 1.16–4.41 for all-cause and cardiac mortality; other predictors were increasing age, CRT, appropriate shocks, ACE-inhibitors, and smoking. Conclusion. Type D personality was independently associated with all-cause and cardiac mortality in younger ICD patients but not in older patients. Cardiovascular research needs to further explore age-related differences in psychosocial risk.

  18. A new methodological approach to assess cardiac work by pressure-volume and stress-length relations in patients with aortic valve stenosis and dilated cardiomyopathy.

    Science.gov (United States)

    Alter, P; Rupp, H; Rominger, M B; Klose, K J; Maisch, B

    2008-01-01

    In experimental animals, cardiac work is derived from pressure-volume area and analyzed further using stress-length relations. Lack of methods for determining accurately myocardial mass has until now prevented the use of stress-length relations in patients. We hypothesized, therefore, that not only pressure-volume loops but also stress-length diagrams can be derived from cardiac volume and cardiac mass as assessed by cardiac magnetic resonance imaging (CMR) and invasively measured pressure. Left ventricular (LV) volume and myocardial mass were assessed in seven patients with aortic valve stenosis (AS), eight with dilated cardiomyopathy (DCM), and eight controls using electrocardiogram (ECG)-gated CMR. LV pressure was measured invasively. Pressure-volume curves were calculated based on ECG triggering. Stroke work was assessed as area within the pressure-volume loop. LV wall stress was calculated using a thick-wall sphere model. Similarly, stress-length loops were calculated to quantify stress-length-based work. Taking the LV geometry into account, the normalization with regard to ventricular circumference resulted in "myocardial work." Patients with AS (valve area 0.73+/-0.18 cm(2)) exhibited an increased LV myocardial mass when compared with controls (Pwork of AS was unchanged when compared with controls (0.539+/-0.272 vs 0.621+/-0.138 Nm, not significant), whereas DCM exhibited a significant depression (0.367+/-0.157 Nm, Pwork was significantly reduced in both AS and DCM when compared with controls (129.8+/-69.6, 200.6+/-80.1, 332.2+/-89.6 Nm/m(2), Pmethodological approach of using CMR and invasive pressure measurement. Myocardial work was reduced in patients with DCM and noteworthy also in AS, while stroke work was reduced in DCM only. Most likely, deterioration of myocardial work is crucial for the prognosis. It is suggested to include these basic physiological procedures in the clinical assessment of the pump function of the heart.

  19. Theoretical analysis of magnetic sensor output voltage

    International Nuclear Information System (INIS)

    Liu Haishun; Dun Chaochao; Dou Linming; Yang Weiming

    2011-01-01

    The output voltage is an important parameter to determine the stress state in magnetic stress measurement, the relationship between the output voltage and the difference in the principal stresses was investigated by a comprehensive application of magnetic circuit theory, magnetization theory, stress analysis as well as the law of electromagnetic induction, and a corresponding quantitative equation was derived. It is drawn that the output voltage is proportional to the difference in the principal stresses, and related to the angle between the principal stress and the direction of the sensor. This investigation provides a theoretical basis for the principle stresses measurement by output voltage. - Research highlights: → A comprehensive investigation of magnetic stress signal. → Derived a quantitative equation about output voltage and the principal stresses. → The output voltage is proportional to the difference of the principal stresses. → Provide a theoretical basis for the principle stresses measurement.

  20. Cardiac function studies

    International Nuclear Information System (INIS)

    Horn, H.J.

    1986-01-01

    A total of 27 patients were subjected tointramyocardial sequential scintiscanning (first pass) using 99m-Tc human serum albumin. A refined method is described that is suitable to analyse clinically relevant parameters like blood volume, cardiac output, ejection fraction, stroke volume, enddiastolic and endsystolic volumes as well as pulmonal transition time and uses a complete camaracomputer system adapted to the requirements of a routine procedure. Unless there is special hardware available, the method does not yet appear mature enough to be put into general practice. Its importance recently appeared in a new light due to the advent of particularly shortlived isotopes. For the time being, however, ECG-triggered equilibrium studies are to be preferred for cardiac function tests. (TRV) [de

  1. The Association Between Urine Output, Creatinine Elevation, and Death.

    Science.gov (United States)

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Necessity of angiotensin-converting enzyme-related gene for cardiac functions and longevity of Drosophila melanogaster assessed by optical coherence tomography

    Science.gov (United States)

    Liao, Fang-Tsu; Chang, Cheng-Yi; Su, Ming-Tsan; Kuo, Wen-Chuan

    2014-01-01

    Prior studies have established the necessity of an angiotensin-converting enzyme-related (ACER) gene for heart morphogenesis of Drosophila. Nevertheless, the physiology of ACER has yet to be comprehensively understood. Herein, we employed RNA interference to down-regulate the expression of ACER in Drosophila's heart and swept source optical coherence tomography to assess whether ACER is required for cardiac functions in living adult flies. Several contractile parameters of Drosophila heart, including the heart rate (HR), end-diastolic diameter (EDD), end-systolic diameter (ESD), percent fractional shortening (%FS), and stress-induced cardiac performance, are shown, which are age dependent. These age-dependent cardiac functions declined significantly when ACER was down-regulated. Moreover, the lifespans of ACER knock-down flies were significantly shorter than those of wild-type control flies. Thus, we posit that ACER, the Drosophila ortholog of mammalian angiotensin-converting enzyme 2 (ACE2), is essential for both heart physiology and longevity of animals. Since mammalian ACE2 controls many cardiovascular physiological features and is implicated in cardiomyopathies, our findings that ACER plays conserved roles in genetically tractable animals will pave the way for uncovering the genetic pathway that controls the renin-angiotensin system.

  3. Cardiac arrest

    Science.gov (United States)

    ... magnesium. These minerals help your heart's electrical system work. Abnormally high or low levels can cause cardiac arrest. Severe physical stress. Anything that causes a severe stress on your ...

  4. Cardiac Ochronosis

    Science.gov (United States)

    Erek, Ersin; Casselman, Filip P.A.; Vanermen, Hugo

    2004-01-01

    We report the case of 67-year-old woman who underwent aortic valve replacement and mitral valve repair due to ochronotic valvular disease (alkaptonuria), which was diagnosed incidentally during cardiac surgery. PMID:15745303

  5. Cardiac catheterization

    Science.gov (United States)

    ... tests. However, it is very safe when done by an experienced team. The risks include: Cardiac tamponade Heart attack Injury to a coronary artery Irregular heartbeat Low blood pressure Reaction to the contrast dye Stroke Possible complications ...

  6. Autonomic cardiac innervation

    Science.gov (United States)

    Hasan, Wohaib

    2013-01-01

    Autonomic cardiac neurons have a common origin in the neural crest but undergo distinct developmental differentiation as they mature toward their adult phenotype. Progenitor cells respond to repulsive cues during migration, followed by differentiation cues from paracrine sources that promote neurochemistry and differentiation. When autonomic axons start to innervate cardiac tissue, neurotrophic factors from vascular tissue are essential for maintenance of neurons before they reach their targets, upon which target-derived trophic factors take over final maturation, synaptic strength and postnatal survival. Although target-derived neurotrophins have a central role to play in development, alternative sources of neurotrophins may also modulate innervation. Both developing and adult sympathetic neurons express proNGF, and adult parasympathetic cardiac ganglion neurons also synthesize and release NGF. The physiological function of these “non-classical” cardiac sources of neurotrophins remains to be determined, especially in relation to autocrine/paracrine sustenance during development.   Cardiac autonomic nerves are closely spatially associated in cardiac plexuses, ganglia and pacemaker regions and so are sensitive to release of neurotransmitter, neuropeptides and trophic factors from adjacent nerves. As such, in many cardiac pathologies, it is an imbalance within the two arms of the autonomic system that is critical for disease progression. Although this crosstalk between sympathetic and parasympathetic nerves has been well established for adult nerves, it is unclear whether a degree of paracrine regulation occurs across the autonomic limbs during development. Aberrant nerve remodeling is a common occurrence in many adult cardiovascular pathologies, and the mechanisms regulating outgrowth or denervation are disparate. However, autonomic neurons display considerable plasticity in this regard with neurotrophins and inflammatory cytokines having a central regulatory

  7. Nuclear cardiac

    International Nuclear Information System (INIS)

    Slutsky, R.; Ashburn, W.L.

    1982-01-01

    The relationship between nuclear medicine and cardiology has continued to produce a surfeit of interesting, illuminating, and important reports involving the analysis of cardiac function, perfusion, and metabolism. To simplify the presentation, this review is broken down into three major subheadings: analysis of myocardial perfusion; imaging of the recent myocardial infarction; and the evaluation of myocardial function. There appears to be an increasingly important relationship between cardiology, particularly cardiac physiology, and nuclear imaging techniques

  8. Cardiac output and vasodilation in the vasovagal response

    DEFF Research Database (Denmark)

    Wieling, Wouter; Jardine, David L.; de Lange, Frederik J

    2016-01-01

    . Plethysmographic measurements were intermittent and not frequent enough to capture rapid changes in blood flow during progressive hypotension. However, later investigations by Weissler, Murray, and Stevens performed between 1950 and 1970 used invasive beat-to-beat BP measurements and more frequent measurements...

  9. Effects of Exercise Training on Haematology and Maximal Cardiac Output

    DEFF Research Database (Denmark)

    Bonne, Thomas Christian

    = 0.051) and time to complete 3000 m tended (P = 0.09) to increase in LHTH but not after sea level training. In study III haematological parameters were determined weekly three times before and four times after classical altitude and sea level training and ABP thresholds for [Hb], %ret, OFF......-score and the abnormal blood profile score (ABPS) were generated using the official ABP software. After altitude training, six swimmers exceeded the 99% ABP thresholds: Two swimmers exceeded the OFF-score thresholds at day 7; One swimmer exceeded the OFF-score threshold at day 28; One swimmer exceeded the threshold...... for %ret at day 14; One swimmer surpassed the ABPS threshold at day 7 and one swimmer exceeded the ABPS threshold 28 days after altitude training. No values exceeded the individual thresholds in the control group. In conclusion, this thesis demonstrated that BV is a main determinant of the exercise induced...

  10. Length dependence of force generation exhibit similarities between rat cardiac myocytes and skeletal muscle fibres.

    Science.gov (United States)

    Hanft, Laurin M; McDonald, Kerry S

    2010-08-01

    According to the Frank-Starling relationship, increased ventricular volume increases cardiac output, which helps match cardiac output to peripheral circulatory demand. The cellular basis for this relationship is in large part the myofilament length-tension relationship. Length-tension relationships in maximally calcium activated preparations are relatively shallow and similar between cardiac myocytes and skeletal muscle fibres. During twitch activations length-tension relationships become steeper in both cardiac and skeletal muscle; however, it remains unclear whether length dependence of tension differs between striated muscle cell types during submaximal activations. The purpose of this study was to compare sarcomere length-tension relationships and the sarcomere length dependence of force development between rat skinned left ventricular cardiac myocytes and fast-twitch and slow-twitch skeletal muscle fibres. Muscle cell preparations were calcium activated to yield 50% maximal force, after which isometric force and rate constants (k(tr)) of force development were measured over a range of sarcomere lengths. Myofilament length-tension relationships were considerably steeper in fast-twitch fibres compared to slow-twitch fibres. Interestingly, cardiac myocyte preparations exhibited two populations of length-tension relationships, one steeper than fast-twitch fibres and the other similar to slow-twitch fibres. Moreover, myocytes with shallow length-tension relationships were converted to steeper length-tension relationships by protein kinase A (PKA)-induced myofilament phosphorylation. Sarcomere length-k(tr) relationships were distinct between all three cell types and exhibited patterns markedly different from Ca(2+) activation-dependent k(tr) relationships. Overall, these findings indicate cardiac myocytes exhibit varied length-tension relationships and sarcomere length appears a dominant modulator of force development rates. Importantly, cardiac myocyte length

  11. Function and modulation of premotor brainstem parasympathetic cardiac neurons that control heart rate by hypoxia-, sleep-, and sleep-related diseases including obstructive sleep apnea.

    Science.gov (United States)

    Dergacheva, Olga; Weigand, Letitia A; Dyavanapalli, Jhansi; Mares, Jacquelyn; Wang, Xin; Mendelowitz, David

    2014-01-01

    Parasympathetic cardiac vagal neurons (CVNs) in the brainstem dominate the control of heart rate. Previous work has determined that these neurons are inherently silent, and their activity is largely determined by synaptic inputs to CVNs that include four major types of synapses that release glutamate, GABA, glycine, or serotonin. Whereas prior reviews have focused on glutamatergic, GABAergic and glycinergic pathways, and the receptors in CVNs activated by these neurotransmitters, this review focuses on the alterations in CVN activity with hypoxia-, sleep-, and sleep-related cardiovascular diseases including obstructive sleep apnea. © 2014 Elsevier B.V. All rights reserved.

  12. Relationship between cardiac function and resting cerebral blood flow

    DEFF Research Database (Denmark)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja

    2014-01-01

    ) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P...... = 0.008) and furthermore lower in males than in females (8.6% versus 12.5%, P = 0.003). Fractional brain flow was also inversely correlated with cerebral white matter lesion grade, although this effect was not significant when adjusted for age. Frequency analysis of heart rate variability showed...

  13. Cardiac failure due to arteriovenous fistula with brachiocephalic stenosis: a gated heart case study

    International Nuclear Information System (INIS)

    Abel, G.; Irish, A.; Henderson, A.; Lenzo, N.

    2003-01-01

    Full text: There are numerous causes of cardiac failure of which the commonest in our community include ischaemic cardiomyopathy, post-viral cardiomyopathy, alcohol-induced cardiomyopathy and drug-induced cardiomyopathy. All these entities cause low output cardiac failure however high output cardiac failure is also well recognised. This includes heart failure related to such conditions as hyperthyroidism, anaemia, pregnancy, beri-beri, and Paget's disease. A rare cause of high output cardiac failure is an arteriovenous fistula. We present an unusual case of a patient with end-stage renal failure on haemodialysis who developed extensive dilatation of their left arm arteriovenous fistula secondary to bachiocephalic vein stenosis. The labelled red blood cell gated heart blood pool study demonstrated decreased left ventricular function and extensive pooling of blood within the tortuous dilated left arm vessels. A follow-up study post-ligation of the arteriovenous fistula showed improvement of the left ventricular ejection fraction. The associated contrast venography findings are also demonstrated. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  14. Myocardial infarction is a frequent cause of exercise-related resuscitated out-of-hospital cardiac arrest in a general non-athletic population.

    Science.gov (United States)

    Søholm, Helle; Kjaergaard, Jesper; Thomsen, Jakob Hartvig; Bro-Jeppesen, John; Lippert, Freddy K; Køber, Lars; Wanscher, Michael; Hassager, Christian

    2014-11-01

    Performing exercise is shown to prevent cardiovascular disease, but the risk of an out-of-hospital cardiac arrest (OHCA) is temporarily increased during strenuous activity. We examined the etiology and outcome after successfully resuscitated OHCA during exercise in a general non-athletic population. Consecutive patients with OHCA were admitted with return of spontaneous circulation (ROSC) or on-going resuscitation at hospital arrival (2002-2011). Patient charts were reviewed for post-resuscitation data. Exercise was defined as moderate/vigorous physical activity. A total of 1393 OHCA-patients were included with 91(7%) arrests occurring during exercise. Exercise-related OHCA-patients were younger (60 ± 13 vs. 65 ± 15, p<0.001) and predominantly male (96% vs. 69%, p<0.001). The arrest was more frequently witnessed (94% vs. 86%, p=0.02), bystander CPR was more often performed (88% vs. 54%, p<0.001), time to ROSC was shorter (12 min (IQR: 5-19) vs. 15 (9-22), p=0.007) and the primary rhythm was more frequently shock-able (91% vs. 49%, p<0.001) compared to non-exercise patients. Cardiac etiology was the predominant cause of OHCA in both exercise and non-exercise patients (97% vs. 80%, p<0.001) and acute coronary syndrome was more frequent among exercise patients (59% vs. 38%, p<0.001). One-year mortality was 25% vs. 65% (p<0.001), and exercise was even after adjustment associated with a significantly lower mortality (HR=0.40 (95%CI: 0.23-0.72), p=0.002). OHCA occurring during exercise was associated with a significantly lower mortality in successfully resuscitated patients even after adjusting for confounding factors. Acute coronary syndrome was more common among exercise-related cardiac arrest patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Neuromuscular diseases after cardiac transplantation

    NARCIS (Netherlands)

    Mateen, Farrah J.; van de Beek, Diederik; Kremers, Walter K.; Daly, Richard C.; Edwards, Brooks S.; McGregor, Christopher G. A.; Wijdicks, Eelco F. M.

    2009-01-01

    BACKGROUND: Cardiac transplantation is a therapeutic option in end-stage heart failure. Peripheral nervous system (PNS) disease is known to occur in cardiac transplant recipients but has not been fully characterized. METHODS: This retrospective cohort review reports the PNS-related concerns of 313

  16. Cardiac CT

    International Nuclear Information System (INIS)

    Dewey, Marc

    2011-01-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  17. Cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2011-07-01

    Computed tomography of the heart has become a highly accurate diagnostic modality that is attracting increasing attention. This extensively illustrated book aims to assist the reader in integrating cardiac CT into daily clinical practice, while also reviewing its current technical status and applications. Clear guidance is provided on the performance and interpretation of imaging using the latest technology, which offers greater coverage, better spatial resolution, and faster imaging. The specific features of scanners from all four main vendors, including those that have only recently become available, are presented. Among the wide range of applications and issues to be discussed are coronary artery bypass grafts, stents, plaques, and anomalies, cardiac valves, congenital and acquired heart disease, and radiation exposure. Upcoming clinical uses of cardiac CT, such as plaque imaging and functional assessment, are also explored. (orig.)

  18. Cardiac echinococcosis

    Directory of Open Access Journals (Sweden)

    Ivanović-Krstić Branislava A.

    2002-01-01

    Full Text Available Cardiac hydatid disease is rare. We report on an uncommon hydatid cyst localized in the right ventricular wall, right atrial wall tricuspid valve left atrium and pericard. A 33-year-old woman was treated for cough, fever and chest pain. Cardiac echocardiograpic examination revealed a round tumor (5.8 x 4 cm in the right ventricular free wall and two smaller cysts behind that tumor. There were cysts in right atrial wall and tricuspidal valve as well. Serologic tests for hydatidosis were positive. Computed tomography finding was consistent with diagnosis of hydatid cyst in lungs and right hylar part. Surgical treatment was rejected due to great risk of cardiac perforation. Medical treatment with albendazole was unsuccessful and the patient died due to systemic hydatid involvement of the lungs, liver and central nervous system.

  19. Débito cardíaco diminuído: revisão sistemática das características definidoras Débito cardíaco disminuído: revisión sistemática de las características definidoras Decreased cardiac output: a systematic review of the defining characteristics

    Directory of Open Access Journals (Sweden)

    Vanessa de Souza

    2011-01-01

    explorada. Se constató la importancia del examen físico, la utilización de técnicas menos invasivas y la necesidad de revisar las características definidoras propuestas a fin de proporcionar claridad y objetividad en la identificación de ese diagnóstico de enfermeríaOBJECTIVES: To characterize the scientific articles related to the NANDA-I nursing diagnosis, decreased cardiac output. Verify those articles that describe the behavior of the defining characteristics of this diagnosis, identifying those that occur with the highest frequency. METHODS: A systematic review of literature published between the years 1985 - 2008 was conducted, using the following databases: Lilacs, SciELO, EMBASE, Medline, Pubmed and Cochrane. RESULTS: The sample included 13 articles which identified 50 defining characteristics. Ten characteristics were noted to occur with high frequency: altered heart rate/rhythm, dyspnea, labile blood pressure, rales, oliguria / anuria, edema, cold skin, fatigue / weakness, decreased peripheral pulses and decreased peripheral perfusion. CONCLUSION: This subject has not been explored in depth in the literature. The importance of physical examination, the use of less invasive techniques, and the need to review the proposed defining characteristics to provide clarity and objectivity in the identification of this nursing diagnosis was identified

  20. Moderate-Intensity Exercise Affects Gut Microbiome Composition and Influences Cardiac Function in Myocardial Infarction Mice

    Directory of Open Access Journals (Sweden)

    Zuheng Liu

    2017-09-01

    Full Text Available Physical exercise is commonly regarded as protective against cardiovascular disease (CVD. Recent studies have reported that exercise alters the gut microbiota and that modification of the gut microbiota can influence cardiac function. Here, we focused on the relationships among exercise, the gut microbiota and cardiac function after myocardial infarction (MI. Four-week-old C57BL/6J mice were exercised on a treadmill for 4 weeks before undergoing left coronary artery ligation. Cardiac function was assessed using echocardiography. Gut microbiomes were evaluated post-exercise and post-MI using 16S rRNA gene sequencing on an Illumina HiSeq platform. Exercise training inhibited declines in cardiac output and stroke volume in post-MI mice. In addition, physical exercise and MI led to alterations in gut microbial composition. Exercise training increased the relative abundance of Butyricimonas and Akkermansia. Additionally, key operational taxonomic units were identified, including 24 lineages (mainly from Bacteroidetes, Barnesiella, Helicobacter, Parabacteroides, Porphyromonadaceae, Ruminococcaceae, and Ureaplasma that were closely related to exercise and cardiac function. These results suggested that exercise training improved cardiac function to some extent in addition to altering the gut microbiota; therefore, they could provide new insights into the use of exercise training for the treatment of CVD.

  1. Post-infarct sleep disruption and its relation to cardiac remodeling in a rat model of myocardial infarction.

    Science.gov (United States)

    Aghajani, Marjan; Faghihi, Mahdieh; Imani, Alireza; Vaez Mahdavi, Mohammad Reza; Shakoori, Abbas; Rastegar, Tayebeh; Parsa, Hoda; Mehrabi, Saman; Moradi, Fatemeh; Kazemi Moghaddam, Ehsan

    2017-01-01

    Sleep disruption after myocardial infarction (MI) by affecting ubiquitin-proteasome system (UPS) is thought to contribute to myocardial remodeling and progressive worsening of cardiac function. The aim of current study was to test the hypothesis about the increased risk of developing heart failure due to experience of sleep restriction (SR) after MI. Male Wistar rats (n = 40) were randomly assigned to four experimental groups: (1) Sham, (2) MI, (3) MI and SR (MI + SR) (4) Sham and SR (Sham + SR). MI was induced by permanent ligation of left anterior descending coronary artery. Twenty-four hours after surgery, animals were subjected to chronic SR paradigm. Blood sampling was performed at days 1, 8 and 21 after MI for determination of serum levels of creatine kinase-MB (CK-MB), corticosterone, malondialdehyde (MDA) and nitric oxide (NO). Finally, at 21 days after MI, echocardiographic parameters and expression of MuRF1, MaFBx, A20, eNOS, iNOS and NF-kB in the heart were evaluated. We used H&E staining to detect myocardial hypertrophy. We found out that post infarct SR increased corticosterone levels. Our results highlighted deteriorating effects of post-MI SR on NO production, oxidative stress, and echocardiographic indexes (p < 0.05). Moreover, its detrimental effects on myocardial damage were confirmed by overexpression of MuRF1, MaFBx, iNOS and NF-kB (p < 0.001) in left ventricle and downregulation of A20 and eNOS (p < 0.05). Furthermore, histological examination revealed that experience of SR after MI increased myocardial diameter as compared to Sham subjects (p < 0.05). Our data suggest that SR after MI leads to an enlargement of the heart within 21 days, marked by an increase in oxidative stress and NO production as well as an imbalance in UPS that ultimately results in cardiac dysfunction and heart failure.

  2. Temperature effects on aerobic scope and cardiac performance of European perch (Perca fluviatilis).

    Science.gov (United States)

    Jensen, Denise Lyager; Overgaard, Johannes; Wang, Tobias; Gesser, Hans; Malte, Hans

    2017-08-01

    Several recent studies have highlighted how impaired cardiac performance at high temperatures and in hypoxia may compromise the capacity for oxygen transport. Thus, at high temperatures impaired cardiac capacity is proposed to reduce oxygen transport to a degree that lowers aerobic scope and compromises thermal tolerance (the oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis). To investigate this hypothesis, we measured aerobic and cardiac performance of a eurythermal freshwater teleost, the European perch (Perca fluviatilis). Rates of oxygen consumption were measured during rest and activity at temperatures between 5°C and 27°C, and we evaluated cardiac function by in vivo measurements of heart rate and in vitro studies to determine contractility of myocardial strips. Aerobic scope increased progressively from 5°C to 21°C, after which it levelled off. Heart rate showed a similar response. We found little difference between resting and active heart rate at high temperature suggesting that increased cardiac scope during activity is primarily related to changes in stroke volume. To examine the effects of temperature on cardiac capacity, we measured isometric force development in electrically paced myocardial preparations during different combinations of temperature, pacing frequency, oxygenation and adrenergic stimulation. The force-frequency product increased markedly upon adrenergic stimulation at 21 and 27°C (with higher effects at 21°C) and the cardiac preparations were highly sensitive to hypoxia. These findings suggest that at (critically) high temperatures, cardiac output may diminish due to a decreased effect of adrenergic stimulation and that this effect may be further exacerbated if the heart becomes hypoxic. Hence cardiac limitations may contribute to the inability to increase aerobic scope at high temperatures in the European perch (Perca fluviatilis). Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. [Cardiac cachexia].

    Science.gov (United States)

    Miján, Alberto; Martín, Elvira; de Mateo, Beatriz

    2006-05-01

    Chronic heart failure (CHF), especially affecting the right heart, frequently leads to malnutrition. If the latter is severe and is combined to other factors, it may lead to cardiac cachexia. This one is associated to increased mortality and lower survival of patients suffering from it. The causes of cardiac cachexia are diverse, generally associated to maintenance of a negative energy balance, with increasing evidence of its multifactorial origin. Neurohumoral, inflammatory, immunological, and metabolic factors, among others, are superimposed in the patient with CHF, leading to involvement and deterioration of several organs and systems, since this condition affects both lean (or active cellular) mass and adipose and bone tissue osteoporosis. Among all, the most pronounced deterioration may be seen at skeletal muscle tissue, at both structural and functional levels, the heart not being spared. As for treatment, it should be based on available scientific evidence. Assessment of nutritional status of any patient with CHF is a must, with the requirement of nutritional intervention in case of malnutrition. In this situation, especially if accompanied by cardiac cachexia, it is required to modify energy intake and oral diet quality, and to consider the indication of specific complementary or alternative artificial nutrition. Besides, the causal relationship of the beneficial role of moderate physical exertion is increasing, as well as modulation of metabolic and inflammatory impairments observed in cardiac cachexia with several drugs, leading to a favorable functional and structural response in CHF patients.

  4. Cardiac Pacemakers

    International Nuclear Information System (INIS)

    Fiandra, O.; Espasandin, W.; Fiandra, H.

    1984-01-01

    A complete survey of physiological biophysical,clinical and engineering aspects of cardiac facing,including the history and an assessment of possible future developments.Among the topics studied are: pacemakers, energy search, heart stimulating with pacemakers ,mathematical aspects of the electric cardio stimulation chronic, pacemaker implants,proceeding,treatment and control

  5. The Complex Role of Store Operated Calcium Entry Pathways and Related Proteins in the Function of Cardiac, Skeletal and Vascular Smooth Muscle Cells

    Directory of Open Access Journals (Sweden)

    Javier Avila-Medina

    2018-03-01

    Full Text Available Cardiac, skeletal, and smooth muscle cells shared the common feature of contraction in response to different stimuli. Agonist-induced muscle's contraction is triggered by a cytosolic free Ca2+ concentration increase due to a rapid Ca2+ release from intracellular stores and a transmembrane Ca2+ influx, mainly through L-type Ca2+ channels. Compelling evidences have demonstrated that Ca2+ might also enter through other cationic channels such as Store-Operated Ca2+ Channels (SOCCs, involved in several physiological functions and pathological conditions. The opening of SOCCs is regulated by the filling state of the intracellular Ca2+ store, the sarcoplasmic reticulum, which communicates to the plasma membrane channels through the Stromal Interaction Molecule 1/2 (STIM1/2 protein. In muscle cells, SOCCs can be mainly non-selective cation channels formed by Orai1 and other members of the Transient Receptor Potential-Canonical (TRPC channels family, as well as highly selective Ca2+ Release-Activated Ca2+ (CRAC channels, formed exclusively by subunits of Orai proteins likely organized in macromolecular complexes. This review summarizes the current knowledge of the complex role of Store Operated Calcium Entry (SOCE pathways and related proteins in the function of cardiac, skeletal, and vascular smooth muscle cells.

  6. Cardiac involvement in female Duchenne and Becker muscular dystrophy carriers in comparison to their first-degree male relatives: a comparative cardiovascular magnetic resonance study.

    Science.gov (United States)

    Florian, Anca; Rösch, Sabine; Bietenbeck, Michael; Engelen, Markus; Stypmann, Jörg; Waltenberger, Johannes; Sechtem, Udo; Yilmaz, Ali

    2016-03-01

    Duchenne (DMD) and Becker (BMD) muscular dystrophies are X-linked recessive disorders associated with both skeletal myopathy and progressive cardiomyopathy in males. Female DMD/BMD carriers (DMDc/BMDc) are mostly free of skeletal muscle symptoms, but they are also prone to cardiomyopathy. The aim of the current study was to characterize the frequency, pattern, and extent of cardiomyopathy in female DMD/BMD carriers (DMDc/BMDc) in comparison to their first-degree male MD relatives. Thirty-six (age 44 ± 14 years) female MD carriers (20 DMDc and 16 BMDc) constituted the 'MD carrier group' and were prospectively enrolled. All MD carriers underwent a complete CMR study comprising cine- and late gadolinium enhancement (LGE) imaging. In 22 of these women ('female MD carrier comparison group', 7 DMD and 15 BMD), at least one first-degree male relative with a previously established diagnosis of MD underwent the same CMR protocol and was assigned to the 'male MD comparison group' (n = 24, 6 DMD and 18 BMD). In the total MD carrier group, 17 (47%) MD carriers had at least one pathological CMR finding [5 (14%) with a reduced left ventricular ejection fraction (LV-EF) and 16 (44%) with the presence of LGE]. All LGE-positive patients (n = 16) showed non-ischaemic LGE with subepicardial involvement of the LV lateral free wall being the most frequent pattern (13/16, 81%). Compared with BMDc, DMDc demonstrated more frequently a pathological CMR result (65 vs. 19%; P = 0.008)--in spite of being significantly younger (40 ± 11 vs. 50 ± 16 years, P = 0.038). In the male MD comparison group, the same LGE pattern as in female carriers was seen, but with a significantly higher prevalence of cardiac abnormalities compared with their female carrier relatives constituting the female MD comparison group (75 vs. 27%; P = 0.003). Cardiac involvement is a frequent finding in female carriers of DMD, but less frequently observed in carriers of BMD. Those DMDc and BMDc with cardiac involvement

  7. Cardiac ablation

    Directory of Open Access Journals (Sweden)

    Kelly Ratheal

    2016-01-01

    Full Text Available Cardiac ablation is a procedure that uses either radiofrequency or cryothermal energy to destroy cells in the heart to terminate and/or prevent arrhythmias. The indications for cardiac catheter ablation include refractory, symptomatic arrhythmias, with more specific guidelines for atrial fibrillation in particular. The ablation procedure itself involves mapping the arrhythmia and destruction of the aberrant pathway in an effort to permanently prevent the arrhythmia. There are many types of arrhythmias, and they require individualized approaches to ablation based on their innately different electrical pathways. Ablation of arrhythmias, such as Wolff-Parkinson-White syndrome, AV nodal reentrant tachycardia, and atrial-fibrillation, is discussed in this review. Ablation has a high success rate overall and minimal complication rates, leading to improved quality of life in many patients.

  8. Evaluation of the cardiac efficiency by means of functional radiocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    A new method of evaluating the cardiac efficiency by means of radiocardiography performed on exertion with /sup 113m/InCl is reported. Analysis of stroke volume, end diastolic volume and of the quotient of cardiac output to end diastolic volume on exertion enables an adequate evaluation of the actual myocardial efficiency.

  9. The effects of balneotherapy on acute, process-related, and cumulative peripheral cardiac responses and pulmonary functions in patients with musculoskeletal disorders.

    Science.gov (United States)

    Şaş, Senem; Toprak Çelenay, Şeyda; Özer Kaya, Derya

    2016-12-20

    This study aimed to evaluate the effects of balneotherapy on acute, process-related, and cumulative peripheral cardiac responses and pulmonary functions in patients with musculoskeletal disorders. Ninety-eight patients with musculoskeletal disorders referred to physiotherapy with balneotherapy were recruited. The patients received balneotherapy for 20 min 5 times per week for 2 weeks. Blood pressure and pulse were measured at the 0th, 5th, 10th, 20th, and 30th minutes during the 1st and 10th sessions. All patients were subjected to pulmonary function testing before balneotherapy and after the 10th session. It was found that systolic blood pressure decreased between the 10th and 20th minutes of the 1st session and between the 10th and 20th minutes and the 20th and 30th minutes of the 10th session (P balneotherapy (P balneotherapy (P Balneotherapy may be effective for improving peripheral cardiopulmonary responses in patients with musculoskeletal disorders.

  10. Transient myocardial ischemia after a first acute myocardial infarction and its relation to clinical characteristics, predischarge exercise testing and cardiac events at one-year follow-up

    DEFF Research Database (Denmark)

    Mickley, H; Pless, P; Nielsen, J R

    1993-01-01

    recording 11 +/- 5 days after AMI 23 patients (19%) had 123 ischemic episodes (group 1), whereas 100 patients demonstrated no ischemia (group 2). Exercise-induced ST-segment depression was more prevalent in group 1 (83%) than in group 2 (47%) (p ... as judged from a shorter exercise duration before significant ST-segment depression (5.5 +/- 2.4 vs 7.7 +/- 4.1 minutes; p depression on exercise testing (4.1 +/- 2.6 vs 2.6 +/- 1.6 mm; p exercise test results revealed an impaired hemodynamic......The relation between early out-of-hospital ambulatory ST-segment monitoring, clinical characteristics, predischarge maximal exercise testing and cardiac events was determined in 123 consecutive men (age 55 +/- 8 years) with a first acute myocardial infarction (AMI). During 36 hours of ambulatory...

  11. Relation between N-terminal pro-brain natriuretic peptide and cardiac remodeling and function assessed by cardiovascular magnetic resonance imaging in patients with arrhythmogenic right ventricular cardiomyopathy.

    Science.gov (United States)

    Cheng, Huaibing; Lu, Minjie; Hou, Cuihong; Chen, Xuhua; Wang, Jing; Yin, Gang; Chu, Jianmin; Zhang, Shu; Prasad, Sanjay K; Pu, Jielin; Zhao, Shihua

    2015-02-01

    Although N-terminal pro-brain natriuretic peptide (NT-proBNP) is a useful screening test of impaired right ventricular (RV) function in conditions affecting the right-sided cardiac muscle, the role of NT-proBNP remains unclear in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). This study was designed to clarify the relation between the plasma NT-proBNP level and the RV function evaluated by cardiovascular magnetic resonance (CMR) imaging. We selected 56 patients with confirmed ARVC only when their blood specimens for NT-proBNP measurements were collected within 48 hours of a CMR scan. The NT-proBNP level was significantly higher in patients with RV dysfunction than in patients without RV dysfunction (median of 655.3 [interquartile range 556.4 to 870.0] vs 347.0 [interquartile range 308.0 to 456.2] pmol/L, p rights reserved.

  12. Acupuncture-like stimulation at auricular point Heart evokes cardiovascular inhibition via activating the cardiac-related neurons in the nucleus tractus solitarius.

    Science.gov (United States)

    Gao, Xin Yan; Li, Yan Hua; Liu, Kun; Rong, Pei Jing; Ben, Hui; Li, Liang; Zhu, Bing; Zhang, Shi Ping

    2011-06-23

    Fifty-eight male Sprague-Dawley rats used in the present study to investigate the role of baroreceptor sensitive neurons of the nucleus tractus solitarius (NTS) in the regulation of cardiovascular inhibition during acupuncture at the auricular point Heart, single unit recording was made in anesthetized Sprague-Dawley rats. A neuron was considered to be excited or inhibited by acupuncture stimulation if it displayed 15% more or less spikes s(-1), respectively. NTS neurons were classified into cardiac-related (CR) neurons and non-cardiac-related neurons based on whether their rhythmic discharges were synchronized with the R-waves and responding to sodium nitroprusside (NP; 20 μg/kg, i.v.) administration. Manual acupuncture was applied at the auricular point Heart and somatic acupuncture points ST36 and PC6. Acupuncture at auricular point Heart showed a more significant inhibitory effect on arterial pressure (-22.1±2.4mm Hg; Pheart rate (-12.7±1.7 bpm; PHeart also increased the level of response of CR neurons in the NTS (93.8%±26.0% increase in discharge rate; Pneurons evoked by auricular acupuncture, but had no effect on the same responses evoked by somatic acupuncture. Inactivation of the NTS with local anesthetics also decreased the cardiovascular inhibitory responses evoked by auricular acupuncture. Our results show that acupuncture at the auricular point Heart regulates cardiovascular function by activating baroreceptor sensitive neurons in the NTS in a similar manner as the baroreceptor reflex in cardiovascular inhibition. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Metoclopramide-induced cardiac arrest

    Directory of Open Access Journals (Sweden)

    Martha M. Rumore

    2011-11-01

    Full Text Available The authors report a case of cardiac arrest in a patient receiving intravenous (IV metoclopramide and review the pertinent literature. A 62-year-old morbidly obese female admitted for a gastric sleeve procedure, developed cardiac arrest within one minute of receiving metoclopramide 10 mg via slow intravenous (IV injection. Bradycardia at 4 beats/min immediately appeared, progressing rapidly to asystole. Chest compressions restored vital function. Electrocardiogram (ECG revealed ST depression indicative of myocardial injury. Following intubation, the patient was transferred to the intensive care unit. Various cardiac dysrrhythmias including supraventricular tachycardia (SVT associated with hypertension and atrial fibrillation occurred. Following IV esmolol and metoprolol, the patient reverted to normal sinus rhythm. Repeat ECGs revealed ST depression resolution without pre-admission changes. Metoclopramide is a non-specific dopamine receptor antagonist. Seven cases of cardiac arrest and one of sinus arrest with metoclopramide were found in the literature. The metoclopramide prescribing information does not list precautions or adverse drug reactions (ADRs related to cardiac arrest. The reaction is not dose related but may relate to the IV administration route. Coronary artery disease was the sole risk factor identified. According to Naranjo, the association was possible. Other reports of cardiac arrest, severe bradycardia, and SVT were reviewed. In one case, five separate IV doses of 10 mg metoclopramide were immediately followed by asystole repeatedly. The mechanism(s underlying metoclopramide’s cardiac arrest-inducing effects is unknown. Structural similarities to procainamide may play a role. In view of eight previous cases of cardiac arrest from metoclopramide having been reported, further elucidation of this ADR and patient monitoring is needed. Our report should alert clinicians to monitor patients and remain diligent in surveillance and

  14. Minimal cardiac transit-times in the diagnosis of heart disease. Measurements with the gamma-retina V and sup(113m)-In. The influence of long-term digitalization on central volume relations in patients with latent and manifest cardiac insufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Freundlieb, C; Vyska, K; Hoeck, A; Schicha, H; Becker, V; Feinendegen, L E [Kernforschungsanlage Juelich G.m.b.H. (F.R. Germany). Inst. fuer Medizin

    1976-02-01

    Using Indium-113m and the Gamma Retina V (Fucks-Knipping Camera), the minimal cardiac transit times (MTTs) were measured radiocardiographically from the right auricle to the aortic root. This analysis served to determine the relation between stroke volume and the segment volume of the part of circulation between the right auricle and the aortic root. In 39 patients with myocardial insufficiency of different clinical degree the effectiveness of digitalization was, up to a period of 5 years, measured by means of the volume relation mentioned above. The following conclusions can be drawn from the results: digitalization of patients with myocardial insufficiency leads to an improvement of the impaired relation of central volumes. In patients with diminished cardiac reserve the improvement is drastic and often results in a nearly complete normalization. The data remain constant during therapy even for an observation period of 5 years. Digitalization of patients with congestive heart failure only leads to a partial improvement. In contrast to patients with diminished cardiac reserve this effect is temporary. The different behaviour of the relation between stroke volume and segment volume in patients with diminished cardiac reserve and congestive heart failure under prolonged administration of digitalis points to the necessity of treatment with digitalis in the early stage of myocardial disease.

  15. Elevation of urinary liver-type fatty acid binding protein after cardiac catheterization related to cardiovascular events

    Directory of Open Access Journals (Sweden)

    Kamijo-Ikemori A

    2015-08-01

    Full Text Available Atsuko Kamijo-Ikemori,1,3 Nobuyuki Hashimoto,2 Takeshi Sugaya,1 Katsuomi Matsui,1 Mikako Hisamichi,1 Yugo Shibagaki,1 Fumihiko Miyake,2 Kenjiro Kimura1 1Department of Nephrology and Hypertension, 2Department of Cardiology, 3Department of Anatomy, St Marianna University School of Medicine, Kawasaki, Kanagawa, Japan Purpose: Contrast medium (CM induces tubular hypoxia via endothelial damage due to direct cytotoxicity or viscosity. Urinary liver-type fatty acid binding protein (L-FABP increases along with tubular hypoxia and may be a detector of systemic circulation injury. The aim of this study was to evaluate the clinical usefulness of detecting increases in urinary L-FABP levels due to administration of CM, as a prognostic biomarker for cardiovascular disease in patients without occurrence of CM-induced nephropathy undergoing cardiac catheterization procedure (CCP. Methods: Retrospective longitudinal analyses of the relationship between urinary L-FABP levels and occurrence of cardiovascular events were performed (n=29. Urinary L-FABP was measured by ELISA before CCP, and at 6, 12, 24, and 48 hours after CCP. Results: Urinary L-FABP levels were significantly higher at 12 hours (P<0.05 and 24 hours (P<0.005 after CCP compared with before CCP, only in the patients with occurrence of cardiovascular events (n=17, but not in those without cardiovascular events (n=12. The parameter with the largest area under the curve (0.816 for predicting the occurrence of cardiovascular events was the change in urinary L-FABP at 24 hours after CCP. The difference in urinary L-FABP levels (ΔL-FABP ≥11.0 µg/g creatinine between before CCP and at 24 hours after CCP was a risk factor for the occurrence of cardiovascular events (hazard ratio, 4.93; 95% confidence interval, 1.27–19.13; P=0.021. Conclusion: Measurement of urinary L-FABP before CCP and at 24 hours after CCP in patients with mild to moderate renal dysfunction may be an important indicator for risk

  16. Inverter communications using output signal

    Science.gov (United States)

    Chapman, Patrick L.

    2017-02-07

    Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

  17. Comparison of health-related quality of life and functional recovery measurement tools in out-of-hospital cardiac arrest survivors.

    Science.gov (United States)

    Andrew, Emily; Nehme, Ziad; Bernard, Stephen; Smith, Karen

    2016-10-01

    Although a number of validated health-related quality of life (HR-QOL) instruments exist for critical care populations, a standardised approach to assessing the HR-QOL of out-of-hospital cardiac arrest (OHCA) survivors has not been developed. We sought to compare the responses of 12-month OHCA survivors to three HR-QOL and functional recovery instruments, and assess instrument validity. The Victorian Ambulance Cardiac Arrest Registry invited 12-month OHCA survivors to participate in telephone follow-up between January 2011 and December 2015. Responders provided answers to the 12 Item Short Form Health Survey (SF-12), Three-Level EuroQol-5D (EQ-5D-3L) and the Glasgow Outcome Scale-Extended (GOSE). The SF-12 was also used to derive the SF-6D. Responses were used to assess the interpretability and construct validity of the instruments. A total of 1188 patients and proxies responded. Large ceiling effects were observed for the EQ-5D-3L (patients=46%, proxies=23%). Substantial variability was also observed in SF-6D responses for patients who reported full health according to the EQ-5D-3L. For patient responders, the strongest correlations were observed between the EQ-5D-3L index score and SF-6D (ρ=0.65, pGOSE outcome and lower or upper good recovery (pGOSE suggest that these may be useful measures of HR-QOL and functional recovery in OHCA survivors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Impact of traffic-related air pollution on acute changes in cardiac autonomic modulation during rest and physical activity: a cross-over study.

    Science.gov (United States)

    Cole-Hunter, Tom; Weichenthal, Scott; Kubesch, Nadine; Foraster, Maria; Carrasco-Turigas, Glòria; Bouso, Laura; Martínez, David; Westerdahl, Dane; de Nazelle, Audrey; Nieuwenhuijsen, Mark

    2016-01-01

    People are often exposed to traffic-related air pollution (TRAP) during physical activity (PA), but it is not clear if PA modifies the impact of TRAP on cardiac autonomic modulation. We conducted a panel study among 28 healthy adults in Barcelona, Spain to examine how PA may modify the impact of TRAP on cardiac autonomic regulation. Participants completed four 2-h exposure scenarios that included either rest or intermittent exercise in high- and low-traffic environments. Time- and frequency-domain measures of heart rate variability (HRV) were monitored during each exposure period along with continuous measures of TRAP. Linear mixed-effects models were used to estimate the impact of TRAP on HRV as well as potential effect modification by PA. Exposure to TRAP was associated with consistent decreases in HRV; however, exposure-response relationships were not always linear over the broad range of exposures. For example, each 10 μg/m(3) increase in black carbon was associated with a 23% (95% CI: -31, -13) decrease in high frequency power at the low-traffic site, whereas no association was observed at the high-traffic site. PA modified the impact of TRAP on HRV at the high-traffic site and tended to weaken inverse associations with measures reflecting parasympathetic modulation (P ≤ 0.001). Evidence of effect modification at the low-traffic site was less consistent. The strength and direction of the relationship between TRAP and HRV may vary across exposure gradients. PA may modify the impact of TRAP on HRV, particularly at higher concentrations.

  19. Human technology after cardiac epigenesis. Artificial heart versus cardiac transplantation.

    Science.gov (United States)

    Losman, J G

    1977-09-24

    Cardiovascular disease is the chief cause of death in technologically advanced countries and accounts for more than 50% of all deaths in the USA. For a patient with end-stage cardiac failure the only treatment presently available is organ replacement, either by transplantation or by the use of a mechanical heart. Transplantation has demonstrated its value: survival of more than 8 years and restoration of a normal quality of life to patients who were in end-stage cardiac decompensation. However, the prospect of routine clinical application of an artificial heart remains distant. The development of a totally implantable artificial heart still presents a series of challenging engineering problems with regard to strict constraints of size, weight, blood-material compatibility, adaptability of output to demand, efficiency and reliability of the power supply, and safety if nuclear fuel is used. The totally artificial heart is presently not an alternative to the cardiac allograft, but could provide short-term support for patients awaiting cardiac transplantation.

  20. Chronic hydrocephalus-induced changes in cerebral blood flow: mediation through cardiac effects.

    Science.gov (United States)

    Dombrowski, Stephen M; Schenk, Soren; Leichliter, Anna; Leibson, Zack; Fukamachi, Kiyotaka; Luciano, Mark G

    2006-10-01

    Decreased cerebral blood flow (CBF) in hydrocephalus is believed to be related to increased intracranial pressure (ICP), vascular compression as the result of enlarged ventricles, or impaired metabolic activity. Little attention has been given to the relationship between cardiac function and systemic blood flow in chronic hydrocephalus (CH). Using an experimental model of chronic obstructive hydrocephalus developed in our laboratory, we investigated the relationship between the duration and severity of hydrocephalus and cardiac output (CO), CBF, myocardial tissue perfusion (MTP), and peripheral blood flow (PBF). Blood flow measures were obtained using the microsphere injection method under controlled hemodynamic conditions in experimental CH (n=23) and surgical control (n=8) canines at baseline and at 2, 4, 8, 12, and 16 weeks. Cardiac output measures were made using the Swan-Ganz thermodilution method. Intracranial compliance (ICC) via cerebrospinal fluid (CSF) bolus removal and infusion, and oxygen delivery in CSF and prefrontal cortex (PFC) were also investigated. We observed an initial surgical effect relating to 30% CO reduction and approximately 50% decrease in CBF, MTP, and PBF in both groups 2 weeks postoperatively, which recovered in control animals but continued to decline further in CH animals at 16 weeks. Cerebral blood flow, which was positively correlated with CO (P=0.028), showed no significant relationship with either CSF volume or pressure. Decreased CBF correlated with oxygen deprivation in PFC (P=0.006). Cardiac output was inversely related with ventriculomegaly (P=0.019), but did not correlate with ICP. Decreased CO corresponded to increased ICC, as measured by CSF infusion (P=0.04). Our results suggest that CH may have more of an influence on CO and CBF in the chronic stage than in the early condition, which was dominated by surgical effect. The cause of this late deterioration of cardiac function in hydrocephalus is uncertain, but may reflect

  1. Three-dimensional display and measurement of cardiac dynamic indexes from MR images

    International Nuclear Information System (INIS)

    Kono, M.; Matsuo, M.; Yamasaki, K.; Banno, T.; Toriwaki, J.; Yokoi, S.; Oshita, H.

    1986-01-01

    The cardiac dynamic index, to which such variables as cardiac output, ejection fraction, and wall motion contribute, is routinely determined using various modalities such as angiography, radionuclide imaging, US, and x-ray CT. Each of these modalities, however, has some disadvantages in regard to evaluating the cardiac dynamic index. The authors have obtained precise multidirectional projection images of the heart by means of computer graphics and reformatted data of cardiac MR images obtained with cardiac gating. The contiguous coronal MR images of the heart are made at an interimage distance of 5 mm. In each section, five or six cardiac images can be obtained, depending on the systolic or diastolic phase. These images are stored in a computer, and a three-dimensional display of the heart with biocular observation and with multiplex holograms is made possible with computer graphics. Three-dimensional measurement of the cardiac index is now being attempted, including cardiac output, ejection fraction, and wall motion

  2. Evaluation of the effect of different types and location of pacemaker on cardiac function using radionuclide techniques

    International Nuclear Information System (INIS)

    Shi Rongfang; Liu Xiujie; Guo Xiuzhen

    1993-01-01

    Left ventricular function was measured in 24 patients using radionuclide ventriculography before and after planting different types of pacemakers. The results showed that the heart rate, peak filling rate (PFR) and relative cardiac output (RCO) were significantly increased after planting the pacemaker. However, the effects of AAI and VVI on the synchronism of LV were different. AAI can significantly improve the synchronism and compliance of LV

  3. Protective Effects of Scutellarin on Human Cardiac Microvascular Endothelial Cells against Hypoxia-Reoxygenation Injury and Its Possible Target-Related Proteins

    Directory of Open Access Journals (Sweden)

    Meina Shi

    2015-01-01

    Full Text Available Scutellarin (SCU is one of the main components of traditional Chinese medicine plant Erigeron breviscapus (Vant. Hand.-Mazz. In this paper, we studied the protective effects of SCU on human cardiac microvascular endothelial cells (HCMECs against hypoxia-reoxygenation (HR injury and its possible target-related proteins. Results of MTT assay showed that pretreatment of SCU at doses of 1, 5, and 10 μM for 2 h could significantly inhibit the decrease in cell viability of HCMECs induced by HR injury. Subcellular fractions of cells treated with vehicle control, 1 μM SCU, HR injury, or 1 μM SCU + HR injury were separated by ultracentrifugation. The protein expression profiles of cytoplasm and membrane/nuclei fractions were checked using protein two-dimensional electrophoresis (2-DE. Proteins differentially expressed between control and SCU-treated group, control and HR group, or HR and SCU + HR group were identified using mass spectrometry (MS/MS. Possible interaction network of these target-related proteins was predicted using bioinformatic analysis. The influence of SCU on the expression levels of these proteins was confirmed using Western blotting assay. The results indicated that proteins such as p27BBP protein (EIF6, heat shock 60 kDa protein 1 (HSPD1, and chaperonin containing TCP1 subunit 6A isoform (CCT6A might play important roles in the effects of SCU.

  4. Protective Effects of Scutellarin on Human Cardiac Microvascular Endothelial Cells against Hypoxia-Reoxygenation Injury and Its Possible Target-Related Proteins.

    Science.gov (United States)

    Shi, Meina; Liu, Yingting; Feng, Lixing; Cui, Yingbo; Chen, Yajuan; Wang, Peng; Wu, Wenjuan; Chen, Chen; Liu, Xuan; Yang, Weimin

    2015-01-01

    Scutellarin (SCU) is one of the main components of traditional Chinese medicine plant Erigeron breviscapus (Vant.) Hand.-Mazz. In this paper, we studied the protective effects of SCU on human cardiac microvascular endothelial cells (HCMECs) against hypoxia-reoxygenation (HR) injury and its possible target-related proteins. Results of MTT assay showed that pretreatment of SCU at doses of 1, 5, and 10 μM for 2 h could significantly inhibit the decrease in cell viability of HCMECs induced by HR injury. Subcellular fractions of cells treated with vehicle control, 1 μM SCU, HR injury, or 1 μM SCU + HR injury were separated by ultracentrifugation. The protein expression profiles of cytoplasm and membrane/nuclei fractions were checked using protein two-dimensional electrophoresis (2-DE). Proteins differentially expressed between control and SCU-treated group, control and HR group, or HR and SCU + HR group were identified using mass spectrometry (MS/MS). Possible interaction network of these target-related proteins was predicted using bioinformatic analysis. The influence of SCU on the expression levels of these proteins was confirmed using Western blotting assay. The results indicated that proteins such as p27BBP protein (EIF6), heat shock 60 kDa protein 1 (HSPD1), and chaperonin containing TCP1 subunit 6A isoform (CCT6A) might play important roles in the effects of SCU.

  5. Microcirculation and its relation to continuous subcutaneous glucose sensor accuracy in cardiac surgery patients in the intensive care unit

    NARCIS (Netherlands)

    Siegelaar, Sarah E.; Barwari, Temo; Hermanides, Jeroen; van der Voort, Peter H. J.; Hoekstra, Joost B. L.; DeVries, J. Hans

    2013-01-01

    Continuous glucose monitoring could be helpful for glucose regulation in critically ill patients; however, its accuracy is uncertain and might be influenced by microcirculation. We investigated the microcirculation and its relation to the accuracy of 2 continuous glucose monitoring devices in

  6. Are Cardiac Autonomic Nervous System Activity and Perceived Stress Related to Functional Somatic Symptoms in Adolescents? The TRAILS Study

    NARCIS (Netherlands)

    K.A.M. Janssens (Karin); H. Riese (Harriëtte); A.M.M. van Roon (Arie); J.A.M. Hunfeld (Joke); Groot, P.F.C. (Paul F. C.); A.J. Oldehinkel (Albertine); J.G.M. Rosmalen (Judith)

    2016-01-01

    textabstractObjective Stressors have been related to medically insufficiently explained or functional somatic symptoms (FSS). However, the underlying mechanism of this association is largely unclear. In the current study, we examined whether FSS are associated with different perceived stress and

  7. GDP Growth, Potential Output, and Output Gaps in Mexico

    OpenAIRE

    Ebrima A Faal

    2005-01-01

    This paper analyzes the sources of Mexico's economic growth since the 1960s and compares various decompositions of historical growth into its trend and cyclical components. The role of the implied output gaps in the inflationary process is then assessed. Looking ahead, the paper presents medium-term paths for GDP based on alternative assumptions for productivity growth rates. The results indicate that the most important factor underlying the slowdown in output growth was a decline in trend to...

  8. Cardiac pacemaker

    International Nuclear Information System (INIS)

    Kolenik, S.A.

    1976-01-01

    The construction of a cardiac pacemaker is described which is characterized by particularly small dimensions, small weight and long life duration. The weight is under 100g, the specific weight under 1.7. Mass inertia forces which occur through acceleration and retardation processes, thus remain below the threshold values, above which one would have to reckon with considerable damaging of the surrounding body tissue. The maintaining of small size and slight weight is achieved by using an oscillator on COSMOS basis, where by considerably lower energy consumption, amongst others the lifetimes of the batteries used - a lithium anode with thionyl chloride electrolyte - is extended to over 5 years. The reliability can be increased by the use of 2 or more batteries. The designed dimension are 20x60x60 mm 3 . (ORU/LH) [de

  9. [Perinatal outcome and cardiac dysfunction in preterm growth-restricted neonates in relation to placental impairment severity].

    Science.gov (United States)

    Candel Pau, Júlia; Castillo Salinas, Félix; Perapoch López, Josep; Carrascosa Lezcano, Antonio; Sánchez García, Olga; Llurba Olivé, Elisa

    2016-10-01

    Intrauterine growth restriction (IUGR) and prematurity have been associated with increased perinatal morbidity and mortality and also with cardiovascular foetal programming. However, there are few studies on the impact of placenta-related IUGR on perinatal outcomes and cardiovascular biomarkers in pre-term infants. To determine differences in neonatal morbidity, mortality and cord blood biomarkers of cardiovascular dysfunction between pre-term placenta-related IUGR and non-IUGR new-borns, and to analyse their relationship with the severity of IUGR according to foetal Doppler evaluation. Prospective cohort study: pre-term infants with placenta-related IUGR and matched pre-term infants without IUGR. A Doppler scan was performed, and placenta-IUGR was classified according to severity. Comparative analysis of perinatal outcomes, neonatal morbidity and mortality, and cord blood levels of biomarkers of cardiovascular dysfunction was performed. IUGR new-borns present lower weight, length, head circumference, and Apgar score at birth, as well as increased neonatal and cardiovascular dysfunction biomarker levels, compared with pre-term new-borns without IUGR. These differences increase with the severity of IUGR determined by prenatal umbilical artery Doppler scan. Placenta-related-IUGR pre-term infants, irrespective of gestational age, present increased neonatal morbidity and mortality that is significantly proportional to the severity of IUGR. Placental impairment and severity also determine levels of cardiovascular dysfunction biomarkers at birth. Copyright © 2015 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Comparison of relative and actual chest compression depths during cardiac arrest in children, adolescents, and young adults☆

    Science.gov (United States)

    Niles, Dana E.; Nishisaki, Akira; Sutton, Robert M.; Nysæther, Jon; Eilevstjønn, Joar; Leffelman, Jessica; Maltese, Matthew R.; Arbogast, Kristy B.; Abella, Benjamin S.; Helfaer, Mark A.; Berg, Robert A.; Nadkarni, Vinay M.

    2013-01-01

    Aim Cardiopulmonary resuscitation (CPR) guidelines recommend specific chest compression (CC) target depths for children. We quantitatively describe relative anterior–posterior diameter (APD) depth, actual depth, and force of CCs during real CPR events in children. Methods CC depth and force were recorded during real CPR events in children ≥8 years using FDA-approved CC sensor. Patient chest APD was measured at conclusion of each CPR event. CC data was stratified and analyzed according to age (pre-puberty, 8–14 years; post-puberty, 15+ years). Relative (% APD) and actual CC depth, corrected for mattress deflection, were assessed and compared with American Heart Association (AHA) 2005 and 2010 pediatric CPR guidelines. Results 35 events in 32 subjects included 16,158 CCs for data analysis: 16 pre-puberty (CCs = 7484, age 11.9 ± 2 years, APD 164.6 ± 25.1 mm); 19 post-puberty (CCs = 8674, age 18.0 ± 2.7 years, APD 196.5 ± 30.4 mm). After correction for mattress deflection, 92% of CC delivered to pre-puberty were resuscitation teams were frequently <1/3 relative APD and <38 mm actual depth after mattress deflection correction, below pediatric and adult target guidelines. Mean CC actual depth and force were not significantly different in pre-puberty and post-puberty. Additional investigation to determine depth of CCs to optimize hemodynamics and outcomes is needed to inform future CPR guidelines. PMID:22079410

  11. Ictal Cardiac Ryhthym Abnormalities.

    Science.gov (United States)

    Ali, Rushna

    2016-01-01

    Cardiac rhythm abnormalities in the context of epilepsy are a well-known phenomenon. However, they are under-recognized and often missed. The pathophysiology of these events is unclear. Bradycardia and asystole are preceded by seizure onset suggesting ictal propagation into the cortex impacting cardiac autonomic function, and the insula and amygdala being possible culprits. Sudden unexpected death in epilepsy (SUDEP) refers to the unanticipated death of a patient with epilepsy not related to status epilepticus, trauma, drowning, or suicide. Frequent refractory generalized tonic-clonic seizures, anti-epileptic polytherapy, and prolonged duration of epilepsy are some of the commonly identified risk factors for SUDEP. However, the most consistent risk factor out of these is an increased frequency of generalized tonic-clonic seizures (GTC). Prevention of SUDEP is extremely important in patients with chronic, generalized epilepsy. Since increased frequency of GTCS is the most consistently reported risk factor for SUDEP, effective seizure control is the most important preventive strategy.

  12. Fetal cardiac assessment

    International Nuclear Information System (INIS)

    Greene, K.R.

    1983-01-01

    The better understanding of fetal cardiovascular physiology coupled with improved technology for non-invasive study of the fetus now enable much more detailed assessment of fetal cardiac status than by heart rate alone. Even the latter, relatively simple, measurement contains much more information than was previously realized. It is also increasingly clear that no single measurement will provide the answer to all clinical dilemmas either on cardiac function or the welfare of the fetus as a whole. There are obvious clinical advantages in measuring several variables from one signal and the measurement of heart rate, heart rate variation and waveform from the ECG in labour is a potentially useful combination. Systolic time intervals or flow measurements could easily be added or used separately by combining real-time and Doppler ultrasound probes

  13. Cardiac molecular-acclimation mechanisms in response to swimming-induced exercise in Atlantic salmon.

    Directory of Open Access Journals (Sweden)

    Vicente Castro

    Full Text Available Cardiac muscle is a principal target organ for exercise-induced acclimation mechanisms in fish and mammals, given that sustained aerobic exercise training improves cardiac output. Yet, the molecular mechanisms underlying such cardiac acclimation have been scarcely investigated in teleosts. Consequently, we studied mechanisms related to cardiac growth, contractility, vascularization, energy metabolism and myokine production in Atlantic salmon pre-smolts resulting from 10 weeks exercise-training at three different swimming intensities: 0.32 (control, 0.65 (medium intensity and 1.31 (high intensity body lengths s(-1. Cardiac responses were characterized using growth, immunofluorescence and qPCR analysis of a large number of target genes encoding proteins with significant and well-characterized function. The overall stimulatory effect of exercise on cardiac muscle was dependent on training intensity, with changes elicited by high intensity training being of greater magnitude than either medium intensity or control. Higher protein levels of PCNA were indicative of cardiac growth being driven by cardiomyocyte hyperplasia, while elevated cardiac mRNA levels of MEF2C, GATA4 and ACTA1 suggested cardiomyocyte hypertrophy. In addition, up-regulation of EC coupling-related genes suggested that exercised hearts may have improved contractile function, while higher mRNA levels of EPO and VEGF were suggestive of a more efficient oxygen supply network. Furthermore, higher mRNA levels of PPARα, PGC1α and CPT1 all suggested a higher capacity for lipid oxidation, which along with a significant enlargement of mitochondrial size in cardiac myocytes of the compact layer of fish exercised at high intensity, suggested an enhanced energetic support system. Training also elevated transcription of a set of myokines and other gene products related to the inflammatory process, such as TNFα, NFκB, COX2, IL1RA and TNF decoy receptor. This study provides the first

  14. Myxedema coma and cardiac ischemia in relation to thyroid hormone replacement therapy in a 38-year-old Japanese woman.

    Science.gov (United States)

    Taguchi, Takafumi; Iwasaki, Yasumasa; Asaba, Koichi; Takao, Toshihiro; Hashimoto, Kozo

    2007-12-01

    Although thyroid hormone deficiency, either clinical or subclinical, is an established risk factor for cardiovascular disease, coronary ischemia in a premenopausal woman in her 30s is relatively rare. A 38-year-old woman was referred to our hospital with severe breathlessness and depressed consciousness. Physical examination found facial, abdominal, and pretibial edema; coarse hair, hoarse voice, and dry skin; engorged jugular veins; a distant heart sound; and reduced bilateral entry of air into the chest. Laboratory examinations revealed severe hypothyroidism, hyperlipidemia, and elevated serum levels of carcinoembryonic antigen (CEA) and carbohydrate antigen 125 (CA125). A computed tomography scan showed massive pleural and pericardial effusions. After 3 months of levothyroxine replacement therapy (initial dose: 12.5 microg/d; maintenance dose: 125 microg/d), all abnormal laboratory values associated with hypothyroidism returned to within normal ranges, with the exception of a transient and paradoxical rise in serum thyroid-stimulating hormone levels. However, 3 weeks after the initiation of therapy, the patient reported intermittent chest pains during the course of therapy, and a coronary artery angiogram revealed diffuse stenosis of all 3 branches. The patient underwent coronary artery bypass grafting, with subsequent improvement in coronary perfusion. Careful cardiovascular evaluation is recommended before the start of thyroid hormone replacement therapy. In addition, care should be taken in the interpretation of serum biomarkers of malignancy (eg, CEA, CA125) in patients with myxedema, as values may be elevated in a hypothyroid state. Long-standing hypothyroidism may be associated with severe coronary atherosclerosis, even in a relatively young, premenopausal woman. The potential adverse cardiovascular effects of thyroid hormone must be considered during replacement therapy, even in relatively young patients.

  15. Relationship between life style-related factors with cardiac ischemia among inpatients: A case-control study

    Directory of Open Access Journals (Sweden)

    Hasan Eftekhar Ardebili

    2015-01-01

    Full Text Available Introduction: More than seventeen millions people die due to cardiovascular diseases which account for one third of death worldwide. Half of 60% of all mortality caused by acquired diseases throughout the world is due to heart disorders and this ratio will augment to 73% by 2020. It is known that individual lifestyle has a great influence on the well-being of cardiovascular system. Seven of the top ten etiologies leading to death are related to the pattern of lifestyle. This study explored various lifestyle-related factors affecting ischemic conditions. Method: This study was performed as a case control investigation on 65 subjects along with 65 controls who were all admitted at Sevome Shaaban hospital in Damavand town of Iran. All data demographic and life-style variables were gathered, using three different types of questionnaire obtained from each person. p< 0.05 was considered as significant. Results: Age, marriage status, smoking, physical activities, diet and mental health condition were shown to have a significant effect on ischemia (P <0.001. Insufficient physical activities, fatty and low fiber food as well as impaired psychology conditions were among the risk factors that contributed to Ischemic heart disease. Conclusion: Insufficient physical activities, fatty and low fiber food as well as impaired psychology conditions were among the risk factors that contribute to ischemic heart disease.

  16. The effects of deoxyelephantopin on the cardiac delayed rectifier potassium channel current (IKr) and human ether-a-go-go-related gene (hERG) expression.

    Science.gov (United States)

    Teah, Yi Fan; Abduraman, Muhammad Asyraf; Amanah, Azimah; Adenan, Mohd Ilham; Sulaiman, Shaida Fariza; Tan, Mei Lan

    2017-09-01

    Elephantopus scaber Linn and its major bioactive component, deoxyelephantopin are known for their medicinal properties and are often reported to have various cytotoxic and antitumor activities. This plant is widely used as folk medicine for a plethora of indications although its safety profile remains unknown. Human ether-a-go-go-related gene (hERG) encodes the cardiac I Kr current which is a determinant of the duration of ventricular action potentials and QT interval. The hERG potassium channel is an important antitarget in cardiotoxicity evaluation. This study investigated the effects of deoxyelephantopin on the current, mRNA and protein expression of hERG channel in hERG-transfected HEK293 cells. The hERG tail currents following depolarization pulses were insignificantly affected by deoxyelephantopin in the transfected cell line. Current reduction was less than 40% as compared with baseline at the highest concentration of 50 μM. The results were consistent with the molecular docking simulation and hERG surface protein expression. Interestingly, it does not affect the hERG expression at both transcriptional and translational level at most concentrations, although higher concentration at 10 μM caused protein accumulation. In conclusion, deoxyelephantopin is unlikely a clinically significant hERG channel and I kr blocker. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Output

    DEFF Research Database (Denmark)

    Mehlsen, Camilla

    2010-01-01

    Hvad får vi egentlig ud af internationale komparative undersøgelser som PISA, PIRLS og TIMSS? Hvordan påvirker de dansk uddannelsespolitik? Asterisk har talt med tre forskere med ekspertise på området.......Hvad får vi egentlig ud af internationale komparative undersøgelser som PISA, PIRLS og TIMSS? Hvordan påvirker de dansk uddannelsespolitik? Asterisk har talt med tre forskere med ekspertise på området....

  18. Gritty people try harder: grit and effort-related cardiac autonomic activity during an active coping challenge.

    Science.gov (United States)

    Silvia, Paul J; Eddington, Kari M; Beaty, Roger E; Nusbaum, Emily C; Kwapil, Thomas R

    2013-05-01

    Grit, a recently proposed personality trait associated with persistence for long-range goals, predicts achievement in a wide range of important life outcomes. Using motivational intensity theory, the present research examined the physiological underpinnings of grit during an active coping task. Forty young adults completed the Short Grit Scale and worked on a self-paced mental effort task. Effort-related autonomic nervous system (ANS) activity was assessed using impedance cardiography, which yielded measures of sympathetic activity (pre-ejection period; PEP) and parasympathetic activity (respiratory sinus arrhythmia; RSA). Multilevel models revealed that people high on the Perseverance of Effort subscale showed autonomic coactivation: both PEP and RSA became stronger during the task, reflecting higher activity of both ANS divisions. The Consistency of Interest subscale, in contrast, predicted only weaker sympathetic activity (slower PEP). Taken together, the findings illuminate autonomic processes associated with how "gritty" people pursue goals, and they suggest that more attention should be paid to the facets' distinct effects. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Cardiac hypertrophy and structural and metabolic remodeling related to seasonal dormancy in the first annual cycle in tegu lizards.

    Science.gov (United States)

    da Silveira, Lilian Cristina; do Nascimento, Lucas Francisco R; Colquhoun, Alison; Abe, Augusto S; de Souza, Silvia Cristina R

    2013-07-01

    Morpho-functional adjustments in the heart of juvenile tegu lizards (Tupinambis merianae) were analyzed at distinct seasonal periods to investigate how the demands of growth and of energy saving are reconciled during the first annual cycle. The relative ventricular mass (Mv) was 31% and 69% larger in late autumn and winter dormancy, respectively, compared to early autumn. This effect did not persist during unfed arousal, suggesting that protein accumulates in the heart during hypometabolism and is degraded on arousal. Both the hypertrophy and the atrophy were disproportionate in the largest individuals. In contrast, Mv was smaller in lizards that were starved during spring activity compared to fed lizards, this effect being larger in smaller individuals. In late autumn and winter dormancy the spongy myocardium had 8% of the section area covered by lacunary spaces, which expanded after food intake during arousal and reached 29% in spring activity together with higher density of cardiomyocytes. Total and soluble proteins per mass unity were unchanged, and maximum activities of selected enzymes suggest sustained glycolytic and aerobic capacities during hypometabolism. Results indicate that important structural adjustments occur in the heart in anticipation of dormancy, and that the protein balance in the tissue is maintained at winter temperatures ~17°C. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Cardiac regeneration therapy: connections to cardiac physiology.

    Science.gov (United States)

    Takehara, Naofumi; Matsubara, Hiroaki

    2011-12-01

    Without heart transplantation, a large number of patients with failing hearts worldwide face poor outcomes. By means of cardiomyocyte regeneration, cardiac regeneration therapy is emerging with great promise as a means for restoring loss of cardiac function. However, the limited success of clinical trials using bone marrow-derived cells and myoblasts with heterogeneous constituents, transplanted at a wide range of cell doses, has led to disagreement on the efficacy of cell therapy. It is therefore essential to reevaluate the evidence for the efficacy of cell-based cardiac regeneration therapy, focusing on targets, materials, and methodologies. Meanwhile, the revolutionary innovation of cardiac regeneration therapy is sorely needed to help the millions of people who suffer heart failure from acquired loss of cardiomyocytes. Cardiac regeneration has been used only in limited species or as a developing process in the rodent heart; now, the possibility of cardiomyocyte turnover in the human heart is being revisited. In the pursuit of this concept, the use of cardiac stem/progenitor stem cells in the cardiac niche must be focused to usher in a second era of cardiac regeneration therapy for the severely injured heart. In addition, tissue engineering and cellular reprogramming will advance the next era of treatment that will enable current cell-based therapy to progress to "real" cardiac regeneration therapy. Although many barriers remain, the prevention of refractory heart failure through cardiac regeneration is now becoming a realistic possibility.

  1. Model output: fact or artefact?

    Science.gov (United States)

    Melsen, Lieke

    2015-04-01

    As a third-year PhD-student, I relatively recently entered the wonderful world of scientific Hydrology. A science that has many pillars that directly impact society, for example with the prediction of hydrological extremes (both floods and drought), climate change, applications in agriculture, nature conservation, drinking water supply, etcetera. Despite its demonstrable societal relevance, hydrology is often seen as a science between two stools. Like Klemeš (1986) stated: "By their academic background, hydrologists are foresters, geographers, electrical engineers, geologists, system analysts, physicists, mathematicians, botanists, and most often civil engineers." Sometimes it seems that the engineering genes are still present in current hydrological sciences, and this results in pragmatic rather than scientific approaches for some of the current problems and challenges we have in hydrology. Here, I refer to the uncertainty in hydrological modelling that is often neglected. For over thirty years, uncertainty in hydrological models has been extensively discussed and studied. But it is not difficult to find peer-reviewed articles in which it is implicitly assumed that model simulations represent the truth rather than a conceptualization of reality. For instance in trend studies, where data is extrapolated 100 years ahead. Of course one can use different forcing datasets to estimate the uncertainty of the input data, but how to prevent that the output is not a model artefact, caused by the model structure? Or how about impact studies, e.g. of a dam impacting river flow. Measurements are often available for the period after dam construction, so models are used to simulate river flow before dam construction. Both are compared in order to qualify the effect of the dam. But on what basis can we tell that the model tells us the truth? Model validation is common nowadays, but validation only (comparing observations with model output) is not sufficient to assume that a

  2. General anxiety, depression, and physical health in relation to symptoms of heart-focused anxiety- a cross sectional study among patients living with the risk of serious arrhythmias and sudden cardiac death

    Directory of Open Access Journals (Sweden)

    Hamang Anniken

    2011-11-01

    Full Text Available Abstract Objective To investigate the role of three distinct symptoms of heart-focused anxiety (cardio-protective avoidance, heart-focused attention, and fear about heart sensations in relation to general anxiety, depression and physical health in patients referred to specialized cardio-genetics outpatient clinics in Norway for genetic investigation and counseling. Methods Participants were 126 patients (mean age 45 years, 53.5% women. All patients were at higher risk than the average person for serious arrhythmias and sudden cardiac death (SCD because of a personal or a family history of an inherited cardiac disorder (familial long QT syndrome or hypertrophic cardiomyopathy. Patients filled in, Hospital Anxiety and Depression Scale, Short-Form 36 Health Survey, and Cardiac Anxiety Questionnaire, two weeks before the scheduled counseling session. Results The patients experienced higher levels of general anxiety than expected in the general population (mean difference 1.1 (p Conclusion Avoidance and fear may be potentially modifiable symptoms. Because these distinct symptoms may have important roles in determining general anxiety, depression and physical health in at-risk individuals of inherited cardiac disorders, the present findings may have implications for the further development of genetic counseling for this patient group.

  3. The Economic Impact of Tourism. An Input-Output Analysis

    OpenAIRE

    Camelia SURUGIU

    2009-01-01

    The paper presents an Input-Output Analysis for Romania, an important source of information for the investigation of the inter-relations existing among different industries. The Input-Output Analysis is used to determine the role and importance of different economic value added, incomes and employment and it analyses the existing connection in an economy. This paper is focused on tourism and the input-output analysis is finished for the Hotels and Restaurants Sector.

  4. Simulation evaluation of quantitative myocardial perfusion assessment from cardiac CT

    Science.gov (United States)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-03-01

    blood flow estimation. In conclusion, quantitative model-based dynamic cardiac CT perfusion assessment is capable of accurately estimating MBF across a range of cardiac outputs and tissue perfusion states, outperforms comparable static perfusion estimates, and is relatively robust to noise and temporal subsampling.

  5. Redesign lifts prep output 288%

    Energy Technology Data Exchange (ETDEWEB)

    Hamric, J

    1987-02-01

    This paper outlines the application of engineering creativity and how it brought output at an Ohio coal preparation plant up from 12,500 tpd to nearly four times that figure, 48,610 tpd. By streamlining the conveyor systems, removing surplus belt length and repositioning subplants the whole operation was able to run far more efficiently with a greater output. Various other alterations including the raw material supply and management and operating practices were also undertaken to provide a test for the achievements possible with such reorganization. The new developments have been in the following fields: fine coal cleaning, heavy media cyclones, feeders, bins, filter presses, dewatering equipment and settling tanks. Output is now limited only by the reduced demand by the Gavin power station nearby.

  6. The incidence of rugby-related catastrophic injuries (including cardiac events) in South Africa from 2008 to 2011: a cohort study

    Science.gov (United States)

    Brown, James Craig; Lambert, Mike I; Verhagen, Evert; Readhead, Clint; van Mechelen, Willem; Viljoen, Wayne

    2013-01-01

    Objectives To establish an accurate and comprehensive injury incidence registry of all rugby union-related catastrophic events in South Africa between 2008 and 2011. An additional aim was to investigate correlates associated with these injuries. Design Prospective. Setting The South African amateur and professional rugby-playing population. Participants An estimated 529 483 Junior and 121 663 Senior rugby union (‘rugby’) players (population at risk). Outcome measures Annual average incidences of rugby-related catastrophic injuries by type (cardiac events, traumatic brain and acute spinal cord injuries (ASCIs)) and outcome (full recoveries—fatalities). Playing level (junior and senior levels), position and event (phase of play) were also assessed. Results The average annual incidence of ASCIs and Traumatic Brain Injuries combined was 2.00 per 100 000 players (95% CI 0.91 to 3.08) from 2008 to 2011. The incidence of ASCIs with permanent outcomes was significantly higher at the Senior level (4.52 per 100 000 players, 95% CI 0.74 to 8.30) than the Junior level (0.24 per 100 000 players, 95% CI 0 to 0.65) during this period. The hooker position was associated with 46% (n=12 of 26) of all permanent ASCI outcomes, the majority of which (83%) occurred during the scrum phase of play. Conclusions The incidence of rugby-related catastrophic injuries in South Africa between 2008 and 2011 is comparable to that of other countries and to most other collision sports. The higher incidence rate of permanent ASCIs at the Senior level could be related to the different law variations or characteristics (eg, less regular training) compared with the Junior level. The hooker and scrum were associated with high proportions of permanent ASCIs. The BokSmart injury prevention programme should focus efforts on these areas (Senior level, hooker and scrum) and use this study as a reference point for the evaluation of the effectiveness of the programme. PMID:23447464

  7. Mitochondrial oxidative stress and cardiac ageing.

    Science.gov (United States)

    Martín-Fernández, Beatriz; Gredilla, Ricardo

    According with different international organizations, cardiovascular diseases are becoming the first cause of death in western countries. Although exposure to different risk factors, particularly those related to lifestyle, contribute to the etiopathogenesis of cardiac disorders, the increase in average lifespan and aging are considered major determinants of cardiac diseases events. Mitochondria and oxidative stress have been pointed out as relevant factors both in heart aging and in the development of cardiac diseases such as heart failure, cardiac hypertrophy and diabetic cardiomyopathy. During aging, cellular processes related with mitochondrial function, such as bioenergetics, apoptosis and inflammation are altered leading to cardiac dysfunction. Increasing our knowledge about the mitochondrial mechanisms related with the aging process, will provide new strategies in order to improve this process, particularly the cardiovascular ones. Copyright © 2017 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Important aspects in relation to patients' attendance at exercise-based cardiac rehabilitation - facilitators, barriers and physiotherapist's role: a qualitative study.

    Science.gov (United States)

    Bäck, Maria; Öberg, Birgitta; Krevers, Barbro

    2017-03-14

    In order to improve attendance at exercise-based cardiac rehabilitation (CR), a greater insight into patients' perspectives is necessary. The aim of the study was to explore aspects that influence patients' attendance at exercise-based CR after acute coronary artery disease (CAD) and the role of the physiotherapist in patients' attendance at exercise-based CR. A total of 16 informants, (5 women; median age 64.5, range 47-79 years), diagnosed with CAD, were included in the study at the Cardiology Department, Linköping University Hospital, Sweden. Qualitative interviews were conducted and analysed according to inductive content analysis. Four main categories were identified: (i) previous experience of exercise, (ii) needs in the acute phase, (iii) important prerequisites for attending exercise-based CR and (iv) future ambitions. The categories demonstrate that there are connections between the past, the present and the future, in terms of attitudes to facilitators, barriers and the use of strategies for managing exercise. An overall theme, defined as existential thoughts, had a major impact on the patients' attitudes to attending exercise-based CR. The interaction and meetings with the physiotherapists in the acute phase were described as important factors for attending exercise-based CR. Moreover, informants could feel that the physiotherapists supported them in learning the right level of effort during exercise and reducing the fear of exercise. This study adds to previous knowledge of barriers and facilitators for exercise-based CR that patients with CAD get existential thoughts both related to exercise during the rehabilitation process and for future attitudes to exercise. This knowledge might necessitate greater attention to the physiotherapist-patient interaction. To be able to tailor exercise-based CR for patients, physiotherapists need to be aware of patients' past experiences of exercise and previous phases of the rehabilitation process as these are

  9. Variable effects of high-dose adrenaline relative to standard-dose adrenaline on resuscitation outcomes according to cardiac arrest duration.

    Science.gov (United States)

    Jeung, Kyung Woon; Ryu, Hyun Ho; Song, Kyung Hwan; Lee, Byung Kook; Lee, Hyoung Youn; Heo, Tag; Min, Yong Il

    2011-07-01

    Adjustment of adrenaline (epinephrine) dosage according to cardiac arrest (CA) duration, rather than administering the same dose, may theoretically improve resuscitation outcomes. We evaluated variable effects of high-dose adrenaline (HDA) relative to standard-dose adrenaline (SDA) on resuscitation outcomes according to CA duration. Twenty-eight male domestic pigs were randomised to the following 4 groups according to the dosage of adrenaline (SDA 0.02 mg/kg vs. HDA 0.2mg/kg) and duration of CA before beginning cardiopulmonary resuscitation (CPR): 6 min SDA, 6 min HDA, 13 min SDA, or 13 min HDA. After the predetermined duration of untreated ventricular fibrillation, CPR was provided. All animals in the 6 min SDA, 6 min HDA, and 13 min HDA groups were successfully resuscitated, while only 4 of 7 pigs in the 13 min SDA group were successfully resuscitated (p=0.043). HDA groups showed higher right atrial pressure, more frequent ventricular ectopic beats, higher blood glucose, higher troponin-I, and more severe metabolic acidosis than SDA groups. Animals of 13 min groups showed more severe metabolic acidosis and higher troponin-I than animals of 6 min groups. All successfully resuscitated animals, except two animals in the 13 min HDA group, survived for 7 days (p=0.121). Neurologic deficit score was not affected by the dose of adrenaline. HDA showed benefit in achieving restoration of spontaneous circulation in 13 min CA, when compared with 6 min CA. However, this benefit did not translate into improved long-term survival or neurologic outcome. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. The Systematic Evaluation of Identifying the Infarct Related Artery Utilizing Cardiac Magnetic Resonance in Patients Presenting with ST-Elevation Myocardial Infarction.

    Directory of Open Access Journals (Sweden)

    Carine E Hamo

    Full Text Available Identification of the infarct-related artery (IRA in patients with STEMI using coronary angiography (CA is often based on the ECG and can be challenging in patients with severe multi-vessel disease. The current study aimed to determine how often percutaneous intervention (PCI is performed in a coronary artery different from the artery supplying the territory of acute infarction on cardiac magnetic resonance imaging (CMR.We evaluated 113 patients from the Reduction of infarct Expansion and Ventricular remodeling with Erythropoetin After Large myocardial infarction (REVEAL trial, who underwent CMR within 4±2 days of revascularization. Blinded reviewers interpreted CA to determine the IRA and CMR to determine the location of infarction on a 17-segment model. In patients with multiple infarcts on CMR, acuity was determined with T2-weighted imaging and/or evidence of microvascular obstruction.A total of 5 (4% patients were found to have a mismatch between the IRA identified on CMR and CA. In 4/5 cases, there were multiple infarcts noted on CMR. Thirteen patients (11.5% had multiple infarcts in separate territories on CMR with 4 patients (3.5% having multiple acute infarcts and 9 patients (8% having both acute and chronic infarcts.In this select population of patients, the identification of the IRA by CA was incorrect in 4% of patients presenting with STEMI. Four patients with a mismatch had an acute infarction in more than one coronary artery territory on CMR. The role of CMR in patients presenting with STEMI with multi-vessel disease on CA deserves further investigation.

  11. Activated nuclear transcription factor κB in patients with myocarditis and dilated cardiomyopathy-relation to inflammation and cardiac function

    International Nuclear Information System (INIS)

    Alter, Peter; Rupp, Heinz; Maisch, Bernhard

    2006-01-01

    Objectives and background: Myocarditis is caused by various agents and autoimmune processes. It is unknown whether viral genome persistence represents inactive remnants of previous infections or whether it is attributed to ongoing adverse processes. The latter also applies to the course of autoimmune myocarditis. One principal candidate for an adverse remodeling is nuclear factor-κB (NFκB). Methods: A total of 93 patients with suspected myocarditis/cardiomyopathy was examined. Hemodynamics were assessed by echocardiography as well as right and left heart catheterization. Endomyocardial biopsies were taken from the left ventricle. Biopsies were examined by immunohistochemistry and PCR for viral genomes. Selective immunostaining of activated NFκB was performed. Results: NFκB was increased in patients with myocarditis when compared with controls (11.1 ± 7.1% vs. 5.0 ± 5.3%, P 2 = 0.72, P 2 = 0.43, P < 0.02). Increased activated NFκB was found in adenovirus persistence when compared with controls (P = 0.001). Only a trend of increased NFκB activation was seen in cytomegalovirus persistence. Parvovirus B19 persistence did not affect NFκB activation. Conclusions: Increased activation of NFκB is related to inflammatory processes in myocarditis. Since activated NFκB correlates with left ventricular function, it could be assumed that NFκB activation occurs at early stages of inflammation. Potentially, NFκB could inhibit loss of cardiomyocytes by apoptosis and protect from cardiac dilation. Since NFκB is a crucial key transcription factor of inflammation, its prognostic and future therapeutic relevance should be addressed

  12. Physiologic stress interventions in cardiac imaging

    International Nuclear Information System (INIS)

    Buda, A.J.

    1985-01-01

    Physiologic stress interventions are designed to assess the reserve capability of coronary flow and myocardial function. In the normal individual, a sufficiently intense physiologic stress may increase coronary flow and cardiac output by 500% to 600%. However, in patients with cardiac disease, these reserve responses may be absent, or considerably blunted. Thus, physiologic stress testing has proved extremely helpful in detecting cardiac abnormalities when resting cardiac function appears normal. Although dynamic exercise remains the standard approach to physiologic stress testing, a number of other interventions have been used, including: (1) isometric exercise, (2) atrial pacing, (3) cold pressor testing, (4) postextrasystolic potentiation, (5) volume loading, and (6) negative intrathoracic pressure. Each of these may be considered an alternative physiologic intervention whenever dynamic exercise is not feasible. These alternative approaches are important since, in our experience, 20% to 30% of subjects are unable to perform dynamic exercise, or exercise inadequately to produce a sufficiently intense cardiac stress. This chapter reviews physiologic considerations, indications, contraindications, protocols, and results of these physiologic stress interventions when used in combination with cardiac radionuclide procedures

  13. World Input-Output Network.

    Directory of Open Access Journals (Sweden)

    Federica Cerina

    Full Text Available Production systems, traditionally analyzed as almost independent national systems, are increasingly connected on a global scale. Only recently becoming available, the World Input-Output Database (WIOD is one of the first efforts to construct the global multi-regional input-output (GMRIO tables. By viewing the world input-output system as an interdependent network where the nodes are the individual industries in different economies and the edges are the monetary goods flows between industries, we analyze respectively the global, regional, and local network properties of the so-called world input-output network (WION and document its evolution over time. At global level, we find that the industries are highly but asymmetrically connected, which implies that micro shocks can lead to macro fluctuations. At regional level, we find that the world production is still operated nationally or at most regionally as the communities detected are either individual economies or geographically well defined regions. Finally, at local level, for each industry we compare the network-based measures with the traditional methods of backward linkages. We find that the network-based measures such as PageRank centrality and community coreness measure can give valuable insights into identifying the key industries.

  14. Remote input/output station

    CERN Multimedia

    1972-01-01

    A general view of the remote input/output station installed in building 112 (ISR) and used for submitting jobs to the CDC 6500 and 6600. The card reader on the left and the line printer on the right are operated by programmers on a self-service basis.

  15. Compact Circuit Preprocesses Accelerometer Output

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1993-01-01

    Compact electronic circuit transfers dc power to, and preprocesses ac output of, accelerometer and associated preamplifier. Incorporated into accelerometer case during initial fabrication or retrofit onto commercial accelerometer. Made of commercial integrated circuits and other conventional components; made smaller by use of micrologic and surface-mount technology.

  16. Body Size Predicts Cardiac and Vascular Resistance Effects on Men's and Women's Blood Pressure

    Directory of Open Access Journals (Sweden)

    Joyce M. Evans

    2017-08-01

    Full Text Available Key Points SummaryWe report how blood pressure, cardiac output and vascular resistance are related to height, weight, body surface area (BSA, and body mass index (BMI in healthy young adults at supine rest and standing.Much inter-subject variability in young adult's blood pressure, currently attributed to health status, may actually result from inter-individual body size differences.Each cardiovascular variable is linearly related to height, weight and/or BSA (more than to BMI.When supine, cardiac output is positively related, while vascular resistance is negatively related, to body size. Upon standing, the change in vascular resistance is positively related to size.The height/weight relationships of cardiac output and vascular resistance to body size are responsible for blood pressure relationships to body size.These basic components of blood pressure could help distinguish normal from abnormal blood pressures in young adults by providing a more effective scaling mechanism.Introduction: Effects of body size on inter-subject blood pressure (BP variability are not well established in adults. We hypothesized that relationships linking stroke volume (SV, cardiac output (CO, and total peripheral resistance (TPR with body size would account for a significant fraction of inter-subject BP variability.Methods: Thirty-four young, healthy adults (19 men, 15 women participated in 38 stand tests during which brachial artery BP, heart rate, SV, CO, TPR, and indexes of body size were measured/calculated.Results: Steady state diastolic arterial BP was not significantly correlated with any index of body size when subjects were supine. However, upon standing, the more the subject weighed, or the taller s/he was, the greater the increase in diastolic pressure. Systolic pressure strongly correlated with body weight and height both supine and standing. Diastolic and systolic BP were more strongly related to height, weight and body surface area than to body mass

  17. Disaggregate energy consumption and industrial output in the United States

    International Nuclear Information System (INIS)

    Ewing, Bradley T.; Sari, Ramazan; Soytas, Ugur

    2007-01-01

    This paper investigates the effect of disaggregate energy consumption on industrial output in the United States. Most of the related research utilizes aggregate data which may not indicate the relative strength or explanatory power of various energy inputs on output. We use monthly data and employ the generalized variance decomposition approach to assess the relative impacts of energy and employment on real output. Our results suggest that unexpected shocks to coal, natural gas and fossil fuel energy sources have the highest impacts on the variation of output, while several renewable sources exhibit considerable explanatory power as well. However, none of the energy sources explain more of the forecast error variance of industrial output than employment

  18. Cardiac integrins the ties that bind.

    Science.gov (United States)

    Simpson, D G; Reaves, T A; Shih, D T; Burgess, W; Borg, T K; Terracio, L

    1998-01-01

    An elaborate series of morphogenetic events must be precisely coordinated during development to promote the formation of the elaborate three-dimensional structure of the normal heart. In this study we focus on discussing how interconnections between the cardiac myocyte and its surrounding environment regulate cardiac form and function. In vitro experiments from our laboratories provide direct evidence that cardiac cell shape is regulated by a dynamic interaction between constituents of the extracellular matrix (ECM) and by specific members of the integrin family of matrix receptors. Our data indicates that phenotypic information is stored in the tertiary structure and chemical identity of the ECM. This information appears to be actively communicated and transduced by the α1β1 integrin molecule into an intracellular signal that regulates cardiac cell shape and myofibrillar organization. In this study we have assessed the phenotypic consequences of suppressing the expression and accumulation of the α1 integrin molecule in aligned cultures of cardiac myocytes. In related experiments we have examined how the overexpression of α2 and α5 integrin, integrins normally not present or present at very low copy number on the cell surface of neonatal cardiac myocytes, affect cardiac protein metabolism. We also consider how biochemical signals and the mechanical signals mediated by the integrins may converge on common intracellular signaling pathways in the heart. Experiments with the whole embryo culture system indicate that angiotensin II, a peptide that carries information concerning cardiac load, plays a role in controling cardiac looping and the proliferation of myofibrils during development.

  19. Glutaredoxin-2 is required to control oxidative phosphorylation in cardiac muscle by mediating deglutathionylation reactions.

    Science.gov (United States)

    Mailloux, Ryan J; Xuan, Jian Ying; McBride, Skye; Maharsy, Wael; Thorn, Stephanie; Holterman, Chet E; Kennedy, Christopher R J; Rippstein, Peter; deKemp, Robert; da Silva, Jean; Nemer, Mona; Lou, Marjorie; Harper, Mary-Ellen

    2014-05-23

    Glutaredoxin-2 (Grx2) modulates the activity of several mitochondrial proteins in cardiac tissue by catalyzing deglutathionylation reactions. However, it remains uncertain whether Grx2 is required to control mitochondrial ATP output in heart. Here, we report that Grx2 plays a vital role modulating mitochondrial energetics and heart physiology by mediating the deglutathionylation of mitochondrial proteins. Deletion of Grx2 (Grx2(-/-)) decreased ATP production by complex I-linked substrates to half that in wild type (WT) mitochondria. Decreased respiration was associated with increased complex I glutathionylation diminishing its activity. Tissue glucose uptake was concomitantly increased. Mitochondrial ATP output and complex I activity could be recovered by restoring the redox environment to that favoring the deglutathionylated states of proteins. Grx2(-/-) hearts also developed left ventricular hypertrophy and fibrosis, and mice became hypertensive. Mitochondrial energetics from Grx2 heterozygotes (Grx2(+/-)) were also dysfunctional, and hearts were hypertrophic. Intriguingly, Grx2(+/-) mice were far less hypertensive than Grx2(-/-) mice. Thus, Grx2 plays a vital role in modulating mitochondrial metabolism in cardiac muscle, and Grx2 deficiency leads to pathology. As mitochondrial ATP production was restored by the addition of reductants, these findings may be relevant to novel redox-related therapies in cardiac disease. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  20. Health Literacy Predicts Cardiac Knowledge Gains in Cardiac Rehabilitation Participants

    Science.gov (United States)

    Mattson, Colleen C.; Rawson, Katherine; Hughes, Joel W.; Waechter, Donna; Rosneck, James

    2015-01-01

    Objective: Health literacy is increasingly recognised as a potentially important patient characteristic related to patient education efforts. We evaluated whether health literacy would predict gains in knowledge after completion of patient education in cardiac rehabilitation. Method: This was a re-post observational analysis study design based on…

  1. Cardiac contractility, central haemodynamics and blood pressure regulation during semistarvation

    DEFF Research Database (Denmark)

    Stokholm, K H; Breum, L; Astrup, A

    1991-01-01

    pressure (BP) declined. The fall in BP was caused by the reduction in cardiac output as the total peripheral resistance was unchanged. Finally, the decline in total blood volume was not significant. These findings together with a reduction in heart rate indicated that a reduced sympathetic tone via......Eight obese patients were studied before and after 2 weeks of treatment by a very-low-calorie diet (VLCD). Cardiac output and central blood volume (pulmonary blood volume and left atrial volume) were determined by indicator dilution (125I-albumin) and radionuclide angiocardiography (first pass...... and equilibrium technique by [99Tcm]red blood cells). Cardiac output decreased concomitantly with the reduction in oxygen uptake as the calculated systemic arteriovenous difference of oxygen was unaltered. There were no significant decreases in left ventricular contractility indices, i.e. the ejection fraction...

  2. An Audit Of Perioperative Cardiac Arrest At Lagos University ...

    African Journals Online (AJOL)

    Objective: Intraoperative cardiac arrests are not uncommon and are related to both surgical and anaesthetic factors. This study aimed to examine the factors which predispose to a periopeartive cardiac arrest, to assess the appropriateness of therapy and the outcome. Materials and Methods: All perioperative cardiac arrests ...

  3. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    Science.gov (United States)

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  4. Diffuse infiltrative cardiac tuberculosis

    International Nuclear Information System (INIS)

    Gulati, Gurpreet S; Kothari, Shyam S

    2011-01-01

    We present the cardiac magnetic resonance images of an unusual form of cardiac tuberculosis. Nodular masses in a sheet-like distribution were seen to infiltrate the outer myocardium and pericardium along most of the cardiac chambers. The lesions showed significant resolution on antitubercular therapy

  5. [Acute cardiac failure in pheochromocytoma.

    DEFF Research Database (Denmark)

    Jønler, Morten; Munk, Kim

    2008-01-01

    Pheochromocytoma (P) is an endocrine catecholamine-secreting tumor. Classical symptoms like hypertension, attacks of sweating, palpitations, headache and palor are related to catecholamine discharge. We provide a case of P in a 71 year-old man presenting with acute cardiac failure, severe reduction...

  6. Cardiac sarcoplasmic reticulum

    International Nuclear Information System (INIS)

    Jacobson, M.S.; Ambudkar, I.S.; Young, E.P.; Naseem, S.M.; Heald, F.P.; Shamoo, A.E.

    1985-01-01

    The effect on the cardiac sarcoplasmic reticulum of an atherogenic (1% cholesterol) diet fed during the neonatal vs the juvenile period of life was studied in Yorkshire swine. Male piglets were randomly assigned at birth to 1 of 4 groups: group I (control), group II (lactation feeding), group III (juvenile period feeding) and group IV (lactation and juvenile feeding). All animals were killed at 55 weeks of age and cardiac sarcoplasmic reticulum (SR) isolated for assay of calcium uptake, Ca 2+ -Mg 2+ ATPase activity, and lipid analysis by thin-layer chromatography and gas chromatography. The amount of cholesterol/mg SR protein and the cholesterol/phospholipid ratio were higher in the animals fed during lactation (groups II and IV) and lower in those fed only during the juvenile period (group III). Phospholipid fatty acid patterns as measured by gas chromatography were unaltered in any group. Calcium uptake was markedly diminished in all experimental conditions: group II 47%, group III 65% and group IV 96%. Compared to the observed changes in calcium transport, the ATP hydrolytic activity was relatively less affected. Only in group IV a significant decrease (41%) was seen. Groups II and III show no change in ATP hydrolytic activity. The decrease in calcium uptake and altered cholesterol/phospholipid ratio without effect on ATP hydrolytic activity is consistent with an uncoupling of calcium transport related to the atherogenic diet in early life. (author)

  7. UFO - The Universal FEYNRULES Output

    Science.gov (United States)

    Degrande, Céline; Duhr, Claude; Fuks, Benjamin; Grellscheid, David; Mattelaer, Olivier; Reiter, Thomas

    2012-06-01

    We present a new model format for automatized matrix-element generators, the so-called Universal FEYNRULES Output (UFO). The format is universal in the sense that it features compatibility with more than one single generator and is designed to be flexible, modular and agnostic of any assumption such as the number of particles or the color and Lorentz structures appearing in the interaction vertices. Unlike other model formats where text files need to be parsed, the information on the model is encoded into a PYTHON module that can easily be linked to other computer codes. We then describe an interface for the MATHEMATICA package FEYNRULES that allows for an automatic output of models in the UFO format.

  8. On output measurements via radiation pressure

    DEFF Research Database (Denmark)

    Leeman, S.; Healey, A.J.; Forsberg, F.

    1990-01-01

    It is shown, by simple physical argument, that measurements of intensity with a radiation pressure balance should not agree with those based on calorimetric techniques. The conclusion is ultimately a consequence of the circumstance that radiation pressure measurements relate to wave momentum, while...... calorimetric methods relate to wave energy. Measurements with some typical ultrasound fields are performed with a novel type of hydrophone, and these allow an estimate to be made of the magnitude of the discrepancy to be expected between the two types of output measurement in a typical case....

  9. Aggregate Supply and Potential Output

    OpenAIRE

    Razin, Assaf

    2004-01-01

    The New-Keynesian aggregate supply derives from micro-foundations an inflation-dynamics model very much like the tradition in the monetary literature. Inflation is primarily affected by: (i) economic slack; (ii) expectations; (iii) supply shocks; and (iv) inflation persistence. This paper extends the New Keynesian aggregate supply relationship to include also fluctuations in potential output, as an additional determinant of the relationship. Implications for monetary rules and to the estimati...

  10. The cardiac sonography workforce in New Zealand

    Science.gov (United States)

    White, Steve; Poppe, Katrina; Whalley, Gillian

    2015-01-01

    Abstract Introduction: The aim of this paper is to investigate the cardiac sonography workforce characteristics and registration requirements in New Zealand (NZ), with a comparison to similar workforces internationally. Methods: The Survey of Clinical Echocardiography in New Zealand 2 (SCANZ2) audit was performed in December 2010. All of NZ's public‐funded District Health Board (DHB) centers providing echocardiography services responded to questions relating to staff, equipment, procedure types and patient statistics. The Medical Radiation Technologists Board (MRTB), Clinical Physiologists Registration Board (CPRB) and Australian Sonographers Association Registry (ASAR) websites were reviewed in March 2012 for registered sonographers with a cardiac scope of practice. The cardiac sonography workforces in Australia, the UK, the USA and Canada were investigated for comparison. Results: There are 84 cardiac sonographers (60.3 full‐time equivalent) working in DHBs: 71% from a cardiac technical background; 40% have post‐graduate qualifications; a further 17% are undertaking post‐graduate qualifications; and 59 cardiac sonographers have registration with professional bodies in NZ and/or Australia. Cardiac sonographers in NZ do not undergo compulsory registration, but other sonographers in NZ have compulsory registration with the MRTB. Sonographers are predominantly not licensed internationally. Discussion: Disparity exists between registration of cardiac and non‐cardiac sonographers in NZ. Many cardiac sonographers have voluntary registration but few are registered with the MRTB. Reasons for this include professional alignment, educational qualifications and representation. International trends show increased pressure from governments and professional bodies to regulate sonographers. Conclusion: This study provides a snapshot of the cardiac sonography workforce in NZ for the first time. PMID:28191178

  11. Roles of PDE1 in Pathological Cardiac Remodeling and Dysfunction.

    Science.gov (United States)

    Chen, Si; Knight, Walter E; Yan, Chen

    2018-04-23

    Pathological cardiac hypertrophy and dysfunction is a response to various stress stimuli and can result in reduced cardiac output and heart failure. Cyclic nucleotide signaling regulates several cardiac functions including contractility, remodeling, and fibrosis. Cyclic nucleotide phosphodiesterases (PDEs), by catalyzing the hydrolysis of cyclic nucleotides, are critical in the homeostasis of intracellular cyclic nucleotide signaling and hold great therapeutic potential as drug targets. Recent studies have revealed that the inhibition of the PDE family member PDE1 plays a protective role in pathological cardiac remodeling and dysfunction by the modulation of distinct cyclic nucleotide signaling pathways. This review summarizes recent key findings regarding the roles of PDE1 in the cardiac system that can lead to a better understanding of its therapeutic potential.

  12. A Novel α-Calcitonin Gene-Related Peptide Analogue Protects Against End-Organ Damage in Experimental Hypertension, Cardiac Hypertrophy and Heart Failure

    DEFF Research Database (Denmark)

    Aubdool, Aisah A; Thakore, Pratish; Argunhan, Fulye

    2017-01-01

    cardiovascular disease in two distinct murine models of hypertension and heart failure in vivoMethods -The ability of the αAnalogue to act selectively via the CGRP pathway was shown in skin using a CGRP receptor antagonist. The effect of the αAnalogue on Angiotensin II (AngII)-induced hypertension......, Western blot and histology. Results -The AngII-induced hypertension was attenuated by co-treatment with the αAnalogue (50nmol/kg/day, s.c., at a dose selected for lack of long term hypotensive effects at baseline). The αAnalogue protected against vascular, renal and cardiac dysfunction, characterised...... failure. It preserved heart function, assessed by echocardiography, whilst protecting against adverse cardiac remodelling and apoptosis. Moreover, treatment with the αAnalogue was well-tolerated with neither signs of desensitisation nor behavioural changes. Conclusions -These findings, in two distinct...

  13. Proteostasis in cardiac health and disease.

    Science.gov (United States)

    Henning, Robert H; Brundel, Bianca J J M

    2017-11-01

    The incidence and prevalence of cardiac diseases, which are the main cause of death worldwide, are likely to increase because of population ageing. Prevailing theories about the mechanisms of ageing feature the gradual derailment of cellular protein homeostasis (proteostasis) and loss of protein quality control as central factors. In the heart, loss of protein patency, owing to flaws in genetically-determined design or because of environmentally-induced 'wear and tear', can overwhelm protein quality control, thereby triggering derailment of proteostasis and contributing to cardiac ageing. Failure of protein quality control involves impairment of chaperones, ubiquitin-proteosomal systems, autophagy, and loss of sarcomeric and cytoskeletal proteins, all of which relate to induction of cardiomyocyte senescence. Targeting protein quality control to maintain cardiac proteostasis offers a novel therapeutic strategy to promote cardiac health and combat cardiac disease. Currently marketed drugs are available to explore this concept in the clinical setting.

  14. Cardiac Rehabilitation: MedlinePlus Health Topic

    Science.gov (United States)

    ... in Spanish Electrocardiogram (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Cardiac Rehabilitation updates ... How to take your pulse Pulse Related Health Topics Heart Attack Heart Diseases How to Prevent Heart ...

  15. Robotic cardiac surgery: an anaesthetic challenge.

    Science.gov (United States)

    Wang, Gang; Gao, Changqing

    2014-08-01

    Robotic cardiac surgery with the da Vinci robotic surgical system offers the benefits of a minimally invasive procedure, including a smaller incision and scar, reduced risk of infection, less pain and trauma, less bleeding and blood transfusion requirements, shorter hospital stay and decreased recovery time. Robotic cardiac surgery includes extracardiac and intracardiac procedures. Extracardiac procedures are often performed on a beating heart. Intracardiac procedures require the aid of peripheral cardiopulmonary bypass via a minithoracotomy. Robotic cardiac surgery, however, poses challenges to the anaesthetist, as the obligatory one-lung ventilation (OLV) and CO2 insufflation may reduce cardiac output and increase pulmonary vascular resistance, potentially resulting in hypoxaemia and haemodynamic compromise. In addition, surgery requires appropriate positioning of specialised cannulae such as an endopulmonary vent, endocoronary sinus catheter, and endoaortic clamp catheter under the guidance of transoesophageal echocardiography. Therefore, cardiac anaesthetists should have a working knowledge of these systems, OLV and haemodynamic support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. [Pulmonary hypertensive crisis in children with idiopathic pulmonary arterial hypertension undergoing cardiac catheterization: the risk factors and clinical aspects].

    Science.gov (United States)

    Zhang, C; Zhu, Y; Li, Q Q; Gu, H

    2018-06-02

    Objective: To investigate the risk factors, clinical features, treatments, and prevention of pulmonary hypertensive crisis (PHC) in children with idiopathic pulmonary arterial hypertension (IPAH) undergoing cardiac catheterization. Methods: This retrospective study included 67 children who were diagnosed with IPAH and underwent cardiac catheterization between April 2009 and June 2017 in Beijing Anzhen Hospital. The medical histories, clinical manifestations, treatments, and outcomes were characterized. Statistical analyses were performed using t test, χ(2) test and a multiple Logistic regression analysis. Results: During cardiac catheterization, five children developed PHC who presented with markedly elevated pulmonary artery pressure and central venous pressure, decline in systemic arterial pressure and oxygen saturation. Heart rate decreased in 4 cases and increased in the remaining one. After the treatments including cardiopulmonary resuscitation, pulmonary vasodilator therapy, improving cardiac output and blood pressure, and correction of acidosis, 4 of the 5 cases recovered, while 1 died of severe right heart failure with irreversible PHC 3 days after operation. Potential PHC was considered in 7 other patients, whose pulmonary artery pressure increased and exceeded systemic arterial pressure, oxygen saturation decreased, and central venous pressure and vital signs were relatively stable. Univariate analysis showed that the risk factors of PHC in children with IPAH undergoing cardiac catheterization were younger age ( t= 3.160, P= 0.004), low weight ( t= 4.004, Phistory of syncope (χ(2)=4.948, P= 0.026), and WHO cardiac functional class Ⅲ or Ⅳ (χ(2)=19.013, Pcatheterization. WHO cardiac functional class may be associated with PHC. Integrated treatment is required for these patients. Reducing risk factors, early identification, and active treatment may help to prevent the occurrence and progression of PHC.

  17. Judicial Influence on Policy Outputs?

    DEFF Research Database (Denmark)

    Martinsen, Dorte Sindbjerg

    2015-01-01

    to override unwanted jurisprudence. In this debate, the Court of Justice of the European Union (CJEU) has become famous for its central and occasionally controversial role in European integration. This article examines to what extent and under which conditions judicial decisions influence European Union (EU......) social policy outputs. A taxonomy of judicial influence is constructed, and expectations of institutional and political conditions on judicial influence are presented. The analysis draws on an extensive novel data set and examines judicial influence on EU social policies over time, that is, between 1958...

  18. Bigger is not better: cortisol-induced cardiac growth and dysfunction in salmonids

    DEFF Research Database (Denmark)

    Johansen, Ida B.; Sandblom, Erik; Skov, Peter Vilhelm

    2017-01-01

    show that rainbow trout (Oncorhynchus mykiss) treated with cortisol in the diet for 45 days have enlarged hearts with lower maximum stroke volume and cardiac output. In accordance with impaired cardiac performance, overall circulatory oxygen-transporting capacity was diminished as indicated by reduced...

  19. Comparação dos efeitos da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio em pacientes submetidos à cirurgia cardíaca com baixo débito cardíaco após indução anestésica Comparación de los efectos de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en pacientes sometidos a cirugía cardiaca con bajo débito cardiaco después de inducción anestésica Comparison of the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in patients undergoing cardiac surgery with low cardiac output after anesthetic induction

    Directory of Open Access Journals (Sweden)

    Maria José Carvalho Carmona

    2010-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Diversas classes de fármacos inotrópicos, com efeitos hemodinâmicos diferentes, são utilizadas no tratamento do baixo débito cardíaco em pacientes com disfunção sistólica submetidos a procedimento cirúrgico cardíaco. O objetivo deste estudo foi comparar o efeito da dobutamina e da milrinona sobre a hemodinâmica e o transporte de oxigênio nessa população de pacientes. MÉTODO: Após aprovação do Comitê de Ética institucional e obtenção do consentimento escrito pós-informado, 20 pacientes submetidos à cirurgia cardíaca e com índice cardíaco JUSTIFICATIVA Y OBJETIVOS: Diversas clases de fármacos inotrópicos con efectos hemodinámicos diferentes, se usan en el tratamiento del bajo débito cardíaco en pacientes con disfunción sistólica sometidos al procedimiento quirúrgico cardíaco. El objetivo de este estudio, fue comparar el efecto de la dobutamina y de la milrinona sobre la hemodinámica y el transporte de oxígeno en esa población de pacientes. MÉTODO: Después de la aprobación del Comité de Ética institucional y de la obtención del consentimiento informado, 20 pacientes sometidos a la cirugía cardíaca y con índice cardíaco BACKGROUND AND OBJECTIVES: Several classes of inotropic drugs with different hemodynamic effects are used in the treatment of low cardiac output in patients with diastolic dysfunction undergoing cardiac surgery. The objective of the present study was to compare the effects of dobutamine and milrinone on hemodynamic parameters and oxygen supply in this population of patients. METHODS: After approval by the Ethics Committee of the institution and signing of the informed consent, 20 patients undergoing cardiac surgery with cardiac index < 2 L.min-1.m2 after anesthetic induction and place ment of a pulmonary artery catheter were randomly divided to receive dobutamine 5 µg.kg-1. min-1 (n = 10, or milrinone 0.5 µg.kg-1.min-1 (n = 10. Hemodynamic parameters were

  20. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  1. Characterization of Glutamatergic Neurons in the Rat Atrial Intrinsic Cardiac Ganglia that Project to the Cardiac Ventricular Wall

    Science.gov (United States)

    Wang, Ting; Miller, Kenneth E.

    2016-01-01

    The intrinsic cardiac nervous system modulates cardiac function by acting as an integration site for regulating autonomic efferent cardiac output. This intrinsic system is proposed to be composed of a short cardio-cardiac feedback control loop within the cardiac innervation hierarchy. For example, electrophysiological studies have postulated the presence of sensory neurons in intrinsic cardiac ganglia for regional cardiac control. There is still a knowledge gap, however, about the anatomical location and neurochemical phenotype of sensory neurons inside intrinsic cardiac ganglia. In the present study, rat intrinsic cardiac ganglia neurons were characterized neurochemically with immunohistochemistry using glutamatergic markers: vesicular glutamate transporters 1 and 2 (VGLUT1; VGLUT2), and glutaminase (GLS), the enzyme essential for glutamate production. Glutamatergic neurons (VGLUT1/VGLUT2/GLS) in the ICG that have axons to the ventricles were identified by retrograde tracing of wheat germ agglutinin-horseradish peroxidase (WGA-HRP) injected in the ventricular wall. Co-labeling of VGLUT1, VGLUT2, and GLS with the vesicular acetylcholine transporter (VAChT) was used to evaluate the relationship between post-ganglionic autonomic neurons and glutamatergic neurons. Sequential labeling of VGLUT1 and VGLUT2 in adjacent tissue sections was used to evaluate the co-localization of VGLUT1 and VGLUT2 in ICG neurons. Our studies yielded the following results: (1) intrinsic cardiac ganglia contain glutamatergic neurons with GLS for glutamate production and VGLUT1 and 2 for transport of glutamate into synaptic vesicles; (2) atrial intrinsic cardiac ganglia contain neurons that project to ventricle walls and these neurons are glutamatergic; (3) many glutamatergic ICG neurons also were cholinergic, expressing VAChT. (4) VGLUT1 and VGLUT2 co-localization occurred in ICG neurons with variation of their protein expression level. Investigation of both glutamatergic and cholinergic ICG

  2. Cardiac amyloidosis

    International Nuclear Information System (INIS)

    Marin, Jorge E; Duque, Mauricio; Medina, Luis E; Uribe, William; Velasquez, Jorge E

    2005-01-01

    Amyloidosis is an infiltrative systemic disease that may involve the heart. it has a genetic etiology and is an important cause of restrictive cardiomyopathy. It may involve all heart structures but has a great affinity for myocardial tissue. Diastolic dysfunction is the most early and frequent manifestation, although due to myocardial infiltration, it may progress to systolic dysfunction, resulting in a rigid heart syndrome. There is also an involvement of the conducting system. The condition may be suspected in any patient with cardiomegalia of unexplained cause. Among the diagnostic tools, the voltage/mass relation may be kept in mind. endomyocardial biopsy is useful although it is not always positive through histological verification. The treatment consists of supportive measures and selected cases may benefit with hepatic transplantation

  3. Pediatric cardiac emergencies: Children are not small adults

    Directory of Open Access Journals (Sweden)

    Frazier Aisha

    2011-01-01

    Full Text Available Compared with adults, cardiac emergencies are infrequent in children and clinical presentation is often quite variable. In adults, cardiac emergencies are most commonly related to complications of coronary artery disease; however, in pediatric cases, the coronaries are only rarely the underlying problem. Pediatric cardiac emergencies comprise a range of pathology including but not limited to undiagnosed congenital heart disease in the infant; complications of palliated congenital heart disease in children; arrhythmias related to underlying cardiac pathology in the teenager and acquired heart disease. The emergency room physician and pediatric intensivist will usually be the first and second lines of care for pediatric cardiac emergencies and thus it is imperative that they have knowledge of the diverse presentations of cardiac disease in order to increase the likelihood of delivering early appropriate therapy and referral. The objective of this review is to outline cardiac emergencies in the pediatric population and contrast the presentation with adults.

  4. Defining the Intrinsic Cardiac Risks of Operations to Improve Preoperative Cardiac Risk Assessments.

    Science.gov (United States)

    Liu, Jason B; Liu, Yaoming; Cohen, Mark E; Ko, Clifford Y; Sweitzer, Bobbie J

    2018-02-01

    Current preoperative cardiac risk stratification practices group operations into broad categories, which might inadequately consider the intrinsic cardiac risks of individual operations. We sought to define the intrinsic cardiac risks of individual operations and to demonstrate how grouping operations might lead to imprecise estimates of perioperative cardiac risk. Elective operations (based on Common Procedural Terminology codes) performed from January 1, 2010 to December 31, 2015 at hospitals participating in the American College of Surgeons National Surgical Quality Improvement Program were studied. A composite measure of perioperative adverse cardiac events was defined as either cardiac arrest requiring cardiopulmonary resuscitation or acute myocardial infarction. Operations' intrinsic cardiac risks were derived from mixed-effects models while controlling for patient mix. Resultant risks were sorted into low-, intermediate-, and high-risk categories, and the most commonly performed operations within each category were identified. Intrinsic operative risks were also examined using a representative grouping of operations to portray within-group variation. Sixty-six low, 30 intermediate, and 106 high intrinsic cardiac risk operations were identified. Excisional breast biopsy had the lowest intrinsic cardiac risk (overall rate, 0.01%; odds ratio, 0.11; 95% CI, 0.02 to 0.25) relative to the average, whereas aorto-bifemoral bypass grafting had the highest (overall rate, 4.1%; odds ratio, 6.61; 95% CI, 5.54 to 7.90). There was wide variation in the intrinsic cardiac risks of operations within the representative grouping (median odds ratio, 1.40; interquartile range, 0.88 to 2.17). A continuum of intrinsic cardiac risk exists among operations. Grouping operations into broad categories inadequately accounts for the intrinsic cardiac risk of individual operations.

  5. Ischemic Stroke Due to Cardiac Involvement: Emery Dreifuss Patient

    Directory of Open Access Journals (Sweden)

    Ersin Kasım Ulusoy

    2015-08-01

    Full Text Available Emery-Dreifuss muscular dystrophy (EDMD is a hereditary disease. It is characterized by early-onset contractures, slowly progressive weakness, fatigue related to skapulo-humero-peroneal muscle weakness, cardiomyopathy which develops in adulthood and cardiac conduction system block. Cardiac involvement has a prognostic significance in patients with EDMD and even sudden cardiac death may be the first clinical presentation. In this article, an EDMD patient with ischemic stroke clinic who didn’t have regular cardiac follow-up was reported and the importance of the treatment of cardiac diseases which could play a role in ischemic stroke etiology and the implantation of pace-maker was mentioned.

  6. Integration of TMVA Output into Jupyter notebooks

    CERN Document Server

    Saliji, Albulena

    2016-01-01

    The purpose of this report is to describe the work that I have been doing during these past eight weeks as a Summer Student at CERN. The task which was assigned to me had to do with the integration of TMVA Output into Jupyter notebooks. In order to integrate the TMVA Output into the Jupyter notebook, first, improvement of the TMVA Output in the terminal was required. Once the output was improved, it needed to be transformed into HTML output and at the end it would be possible to integrate that output into the Jupyter notebook.

  7. Alterações hemodinâmicas devido ao uso de estabilizadores em revascularização do miocárdio: estudo experimental Hemodynamic disorders related to beating heart surgery using cardiac stabilizers: experimental study

    Directory of Open Access Journals (Sweden)

    Pedro Paulo Martins de Oliveira

    2007-12-01

    -pump coronary artery bypass graft surgeries by means of both a suction device "Octopus" and a compression device (Speroni. METHODS: Ten swine underwent median sternotomy. Monitoring of ECG, continuous cardiac output, mean arterial pressure, mean pulmonary artery pressure, mean right and left atrial pressures, and right and left ventricular diastolic pressure were performed. Stroke volume and systemic vascular resistance were calculated. Both stabilizers were studied placed on three vessels: anterior interventricular branch, posterior interventricular branch, and marginal branch of the circumflex branch. Each animal was randomly designed to application regarding the type of stabilizer and the target artery. The measurements were carried out 5 minutes before and after the stabilizer application. RESULTS: In the anterior interventricular branch changes have occurred only with the compression device, thus reducing cardiac output, stroke volume, and mean arterial pressure, but increasing the systemic vascular resistance. In the posterior interventricular branch changes have occurred with the compression device (Speroni, reducing cardiac output and stroke volume, but increasing the heart rate. With the suction device (octopus there was an increase of both heart rate and systemic vascular resistance, but a decrease in stroke volume. In the marginal branch of the circumflex branch there was a decrease of cardiac output, stroke volume, and mean arterial pressure with both stabilizers. Also, there was a decrease in the mean pulmonary artery pressure and an increase in the mean right atrial pressure with the compression device (Speroni. CONCLUSION: Both stabilizers have caused hemodynamic changes. The compression device (Speroni is more associated with changes than the suction device (Octopus.

  8. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  9. Galectin-3, a marker of cardiac remodeling, is inversely related to serum levels of marine omega-3 fatty acids. A cross-sectional study

    DEFF Research Database (Denmark)

    Laake, K; Seljeflot, I; Schmidt, E B

    2017-01-01

    OBJECTIVE: Marine polyunsaturated n-3 fatty acids (n-3 PUFA) may have cardioprotective effects and beneficial influence on the fibrotic process. We evaluated the associations between serum marine n-3 PUFA and selected biomarkers of fibrosis and cardiac remodeling in elderly patients with acute...... myocardial infarction. RESULTS: Gal-3 was inversely correlated to eicosapentaenoic acid (r = -.120, p = .039) and docosahexaenoic acid (r = -.125, p = .031) and positively correlated to the n-6/n-3 ratio (r = .131, p = .023). Gal-3 levels were significantly higher in diabetics vs non-diabetics (12.00 vs 9.......61 ng/mL, p = .007) and in patients with NYHA class ≥III for dyspnea at inclusion (11.33 vs 9.75 ng/mL, p = .006). CONCLUSIONS: The associations between the marine n-3 PUFA and levels of Gal-3 indicate beneficial effects of n-3 PUFA on cardiac remodeling in an elderly population with acute myocardial...

  10. A heart that beats for 500 years: age-related changes in cardiac proteasome activity, oxidative protein damage and expression of heat shock proteins, inflammatory factors, and mitochondrial complexes in Arctica islandica, the longest-living noncolonial animal.

    Science.gov (United States)

    Sosnowska, Danuta; Richardson, Chris; Sonntag, William E; Csiszar, Anna; Ungvari, Zoltan; Ridgway, Iain

    2014-12-01

    Study of negligibly senescent animals may provide clues that lead to better understanding of the cardiac aging process. To elucidate mechanisms of successful cardiac aging, we investigated age-related changes in proteasome activity, oxidative protein damage and expression of heat shock proteins, inflammatory factors, and mitochondrial complexes in the heart of the ocean quahog Arctica islandica, the longest-lived noncolonial animal (maximum life span potential: 508 years). We found that in the heart of A. islandica the level of oxidatively damaged proteins did not change significantly up to 120 years of age. No significant aging-induced changes were observed in caspase-like and trypsin-like proteasome activity. Chymotrypsin-like proteasome activity showed a significant early-life decline, then it remained stable for up to 182 years. No significant relationship was observed between the extent of protein ubiquitination and age. In the heart of A. islandica, an early-life decline in expression of HSP90 and five mitochondrial electron transport chain complexes was observed. We found significant age-related increases in the expression of three cytokine-like mediators (interleukin-6, interleukin-1β, and tumor necrosis factor-α) in the heart of A. islandica. Collectively, in extremely long-lived molluscs, maintenance of protein homeostasis likely contributes to the preservation of cardiac function. Our data also support the concept that low-grade chronic inflammation in the cardiovascular system is a universal feature of the aging process, which is also manifest in invertebrates. © The Author 2013. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Observability of linear systems with saturated outputs

    NARCIS (Netherlands)

    Koplon, R.; Sontag, E.D.; Hautus, M.L.J.

    1994-01-01

    We present necessary and sufficient conditions for observability of the class of output-saturated systems. These are linear systems whose output passes through a saturation function before it can be measured.

  12. Radiation exposure during cardiac catheterization procedures

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Huyskens, C.J.; Michels, H.R.

    1988-01-01

    For some time there has been an increased interest in more information about radiation exposure during cardiac catheterization because of: relatively high doses to workers and patient; rapid increase of numbers of examinations; introduction of new procedure-types (e.g. Percutaneous Transluminal Coronary Angiography, PTCA) and introduction of new techniques (e.g. Digital Subtraction Angiography, DSA). This paper reports about a study on the exposure to medical personnel and patient in two major hospitals in the Netherlands. The Total number of cardiac catheterization procedures in both hospitals amounts to circa 3000 per year (approximately 10% of all cardiac procedures c.q. 20% of all PTCA procedures in the Netherlands). This study is related to 1300 cardiac examinations

  13. Output Feedback M-MRAC Backstepping With Aerospace Applications

    Science.gov (United States)

    Stepanyan, Vahram; Krishnakumar, Kalmanje Sriniva

    2014-01-01

    The paper presents a certainty equivalence output feedback backstepping adaptive control design method for the systems of any relative degree with unmatched uncertainties without over-parametrization. It uses a fast prediction model to estimate the unknown parameters, which is independent of the control design. It is shown that the system's input and output tracking errors can be systematically decreased by the proper choice of the design parameters. The approach is applied to aerospace control problems and tested in numerical simulations.

  14. Input and output constraints affecting irrigation development

    Science.gov (United States)

    Schramm, G.

    1981-05-01

    In many of the developing countries the expansion of irrigated agriculture is used as a major development tool for bringing about increases in agricultural output, rural economic growth and income distribution. Apart from constraints imposed by water availability, the major limitations considered to any acceleration of such programs are usually thought to be those of costs and financial resources. However, as is shown on the basis of empirical data drawn from Mexico, in reality the feasibility and effectiveness of such development programs is even more constrained by the lack of specialized physical and human factors on the input and market limitations on the output side. On the input side, the limited availability of complementary factors such as, for example, truly functioning credit systems for small-scale farmers or effective agricultural extension services impose long-term constraints on development. On the output side the limited availability, high risk, and relatively slow growth of markets for high-value crops sharply reduce the usually hoped-for and projected profitable crop mix that would warrant the frequently high costs of irrigation investments. Three conclusions are drawn: (1) Factors in limited supply have to be shadow-priced to reflect their high opportunity costs in alternative uses. (2) Re-allocation of financial resources from immediate construction of projects to longer-term increase in the supply of scarce, highly-trained manpower resources are necessary in order to optimize development over time. (3) Inclusion of high-value, high-income producing crops in the benefit-cost analysis of new projects is inappropriate if these crops could potentially be grown in already existing projects.

  15. Crisis management during anaesthesia: cardiac arrest.

    Science.gov (United States)

    Runciman, W B; Morris, R W; Watterson, L M; Williamson, J A; Paix, A D

    2005-06-01

    Cardiac arrest attributable to anaesthesia occurs at the rate of between 0.5 and 1 case per 10 000 cases, tends to have a different profile to that of cardiac arrest occurring elsewhere, and has an in-hospital mortality of 20%. However, as individual practitioners encounter cardiac arrest rarely, the rapidity with which the diagnosis is made and the consistency of appropriate management varies considerably. To examine the role of a previously described core algorithm "COVER ABCD-A SWIFT CHECK", supplemented by a sub-algorithm for cardiac arrest, in the management of cardiac arrest occurring in association with anaesthesia. The potential performance of this structured approach for each the relevant incidents among the first 4000 reported to the Australian Incident Monitoring Study (AIMS) was compared with the actual management as reported by the anaesthetists involved. There were 129 reports of cardiac arrest associated with anaesthesia among the first 4000 AIMS incident reports. Identified aetiological factors were grouped into five categories: (1) anaesthetic technique (11 cases with this category alone; 32 with this and one or more of the other categories, representing 25% of all 129 cardiac arrests); (2) drug related (16; 32, 25%); (3) associated with surgical procedure (9; 29, 22%); (4) associated with pre-existing medical or surgical disease (30; 82, 64%); (5) unknown (8; 14, 11%). The "real life" presentation and management of cardiac arrest in association with anaesthesia differs substantially from that detailed in general published guidelines. Cardiac rhythms at the time were sinus bradycardia (23%); asystole (22%); tachycardia/ventricular tachycardia/ventricular fibrillation (14%); and normal (7%), with a further third unknown. Details of treatment were recorded in 110 reports; modalities employed included cardiac compression (72%); adrenaline (61%); 100% oxygen (58%); atropine (38%); intravenous fluids (25%), and electrical defibrillation (17%). There

  16. Traction force microscopy of engineered cardiac tissues.

    Science.gov (United States)

    Pasqualini, Francesco Silvio; Agarwal, Ashutosh; O'Connor, Blakely Bussie; Liu, Qihan; Sheehy, Sean P; Parker, Kevin Kit

    2018-01-01

    Cardiac tissue development and pathology have been shown to depend sensitively on microenvironmental mechanical factors, such as extracellular matrix stiffness, in both in vivo and in vitro systems. We present a novel quantitative approach to assess cardiac structure and function by extending the classical traction force microscopy technique to tissue-level preparations. Using this system, we investigated the relationship between contractile proficiency and metabolism in neonate rat ventricular myocytes (NRVM) cultured on gels with stiffness mimicking soft immature (1 kPa), normal healthy (13 kPa), and stiff diseased (90 kPa) cardiac microenvironments. We found that tissues engineered on the softest gels generated the least amount of stress and had the smallest work output. Conversely, cardiomyocytes in tissues engineered on healthy- and disease-mimicking gels generated significantly higher stresses, with the maximal contractile work measured in NRVM engineered on gels of normal stiffness. Interestingly, although tissues on soft gels exhibited poor stress generation and work production, their basal metabolic respiration rate was significantly more elevated than in other groups, suggesting a highly ineffective coupling between energy production and contractile work output. Our novel platform can thus be utilized to quantitatively assess the mechanotransduction pathways that initiate tissue-level structural and functional remodeling in response to substrate stiffness.

  17. Probabilistic Output Analysis by Program Manipulation

    DEFF Research Database (Denmark)

    Rosendahl, Mads; Kirkeby, Maja Hanne

    2015-01-01

    The aim of a probabilistic output analysis is to derive a probability distribution of possible output values for a program from a probability distribution of its input. We present a method for performing static output analysis, based on program transformation techniques. It generates a probability...

  18. Experimental characterization of variable output refractive beamshapers using freeform elements

    Science.gov (United States)

    Shultz, Jason A.; Smilie, Paul J.; Dutterer, Brian S.; Davies, Matthew A.; Suleski, Thomas J.

    2014-09-01

    We present experimental results from variable output refractive beam shapers based on freeform optical surfaces. Two freeform elements in close proximity comprise a beam shaper that maps a circular Gaussian input to a circular `flat-top' output. Different lateral relative shifts between the elements result in a varying output diameter while maintaining the uniform irradiance distribution. We fabricated the beam shaping elements in PMMA using multi-axis milling on a Moore Nanotech 350FG diamond machining center and tested with a 632.8 nm Gaussian input. Initial optical testing confirmed both the predicted beam shaping and variable functionality, but with poor output uniformity. The effects of surface finish on optical performance were investigated using LightTrans VirtualLabTM to perform physical optics simulations of the milled freeform surfaces. These simulations provided an optimization path for determining machining parameters to improve the output uniformity of the beam shaping elements. A second variable beam shaper based on a super-Gaussian output was designed and fabricated using the newly determined machining parameters. Experimental test results from the second beam shaper showed outputs with significantly higher quality, but also suggest additional areas of study for further improvements in uniformity.

  19. Scintigraphic assessment of heterotopic cardiac transplants

    International Nuclear Information System (INIS)

    Wilson, M.A.; Kahn, D.R.

    1981-01-01

    Patients receiving heterotopic (''piggyback'') cardiac transplants, when the patient's own and transplanted donor hearts are connected in parallel, present special problems in determining their relative contributions to total cardiac function. Three patients who had transplants because of intractable heart failure were studied using first pass and gated equilibrium technetium-99m-labeled blood pool scintigraphy. In one patient, thallium-201 myocardial perfusion scans were obtained. These nuclear cardiology techniques provided anatomic and functional information noninvasively that proved helpful in patient management

  20. Effects of plasma viscosity modulation on cardiac function during moderate hemodilution

    Directory of Open Access Journals (Sweden)

    Chatpun Surapong

    2010-01-01

    Full Text Available Background : Previous studies have found that increasing plasma viscosity as whole blood viscosity decrease has beneficial effects in microvascular hemodynamics. As the heart couples with systemic vascular network, changes in plasma and blood viscosity during hemodilution determine vascular pressure drop and flow rate, which influence cardiac function. This study aimed to investigate how changes in plasma viscosity affect on cardiac function during acute isovolemic hemodilution. Materials and Methods: Plasma viscosity was modulated by hemodilution of 40% of blood volume with three different plasma expanders (PEs. Dextran 2000 kDa (Dx2M, 6.3 cP and dextran 70 kDa (Dx70, 3.0 cP were used as high and moderate viscogenic PEs, respectively. Polyethylene glycol conjugated with human serum albumin (PEG-HSA, 2.2 cP was used as low viscogenic PE. The cardiac function was assessed using a miniaturized pressure-volume conductance catheter. Results: After hemodilution, pressure dropped to 84%, 79%, and 78% of baseline for Dx2M, Dx70 and PEG-HSA, respectively. Cardiac output markedly increased for Dx2M and PEG-HSA. Dx2M significantly produced higher stroke work relative to baseline and compared to Dx70. Conclusion: Acute hemodilution with PEG-HSA without increasing plasma viscosity provided beneficial effects on cardiac function compared to Dx70, and similar to those measured with Dx2M. Potentially negative effects of increasing peripheral vascular resistance due to the increase in plasma viscosity were prevented.

  1. Mediastinitis after cardiac transplantation

    Directory of Open Access Journals (Sweden)

    Noedir A. G. Stolf

    2000-05-01

    Full Text Available OBJECTIVE: Assessment of incidence and behavior of mediastinitis after cardiac transplantation. METHODS: From 1985 to 1999, 214 cardiac transplantations were performed, 12 (5.6% of the transplanted patients developed confirmed mediastinitis. Patient's ages ranged from 42 to 66 years (mean of 52.3±10.0 years and 10 (83.3% patients were males. Seven (58.3% patients showed sternal stability on palpation, 4 (33.3% patients had pleural empyema, and 2 (16.7% patients did not show purulent secretion draining through the wound. RESULTS: Staphylococcus aureus was the infectious agent identified in the wound secretion or in the mediastinum, or both, in 8 (66.7% patients. Staphylococcus epidermidis was identified in 2 (16.7% patients, Enterococcus faecalis in 1 (8.3% patient, and the cause of mediastinitis could not be determined in 1 (8.3% patient. Surgical treatment was performed on an emergency basis, and the extension of the débridement varied with local conditions. In 2 (16.7% patients, we chose to leave the surgical wound open and performed daily dressings with granulated sugar. Total sternal resection was performed in only 1 (8.3% patient. Out of this series, 5 (41.7% patients died, and the causes of death were related to the infection. Autopsy revealed persistence of mediastinitis in 1 (8.3% patient. CONCLUSION: Promptness in diagnosing mediastinitis and precocious surgical drainage have changed the natural evolution of this disease. Nevertheless, observance of the basic precepts of prophylaxis of infection is still the best way to treat mediastinitis.

  2. Polymer microfiber meshes facilitate cardiac differentiation of c-kit{sup +} human cardiac stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Kan, Lijuan [Department of Biomedical Sciences and Pathobiology, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA (United States); Thayer, Patrick [Department of Chemical Engineering, School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA (United States); Fan, Huimin [Research Institute of Heart Failure, Shanghai East Hospital of Tongji University, Shanghai (China); Ledford, Benjamin; Chen, Miao [Department of Biomedical Sciences and Pathobiology, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA (United States); Goldstein, Aaron [Department of Chemical Engineering, School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA (United States); Cao, Guohua [School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA (United States); He, Jia-Qiang, E-mail: jiahe@vt.edu [Department of Biomedical Sciences and Pathobiology, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA (United States)

    2016-09-10

    Electrospun microfiber meshes have been shown to support the proliferation and differentiation of many types of stem cells, but the phenotypic fate of c-kit{sup +} human cardiac stem cells (hCSCs) have not been explored. To this end, we utilized thin (~5 µm) elastomeric meshes consisting of aligned 1.7 µm diameter poly (ester-urethane urea) microfibers as substrates to examine their effect on hCSC viability, morphology, proliferation, and differentiation relative to cells cultured on tissue culture polystyrene (TCPS). The results showed that cells on microfiber meshes displayed an elongated morphology aligned in the direction of fiber orientation, lower proliferation rates, but increased expressions of genes and proteins majorly associated with cardiomyocyte phenotype. The early (NK2 homeobox 5, Nkx2.5) and late (cardiac troponin I, cTnI) cardiomyocyte genes were significantly increased on meshes (Nkx=2.5 56.2±13.0, cTnl=2.9±0.56,) over TCPS (Nkx2.5=4.2±0.9, cTnl=1.6±0.5, n=9, p<0.05 for both groups) after differentiation. In contrast, expressions of smooth muscle markers, Gata6 and myosin heavy chain (SM-MHC), were decreased on meshes. Immunocytochemical analysis with cardiac antibody exhibited the similar pattern of above cardiac differentiation. We conclude that aligned microfiber meshes are suitable for guiding cardiac differentiation of hCSCs and may facilitate stem cell-based therapies for treatment of cardiac diseases. - Highlights: • First study to characterize c-kit{sup +} human cardiac stem cells on microfiber meshes. • Microfiber meshes seem reducing cell proliferation, but no effect on cell viability. • Microfiber meshes facilitate the elongation of human cardiac stem cells in culture. • Cardiac but not smooth muscle differentiation were enhanced on microfiber meshes. • Microfiber meshes may be used as cardiac patches in cell-based cardiac therapy.

  3. Safety in cardiac surgery

    NARCIS (Netherlands)

    Siregar, S.

    2013-01-01

    The monitoring of safety in cardiac surgery is a complex process, which involves many clinical, practical, methodological and statistical issues. The objective of this thesis was to measure and to compare safety in cardiac surgery in The Netherlands using the Netherlands Association for

  4. Cardiac Catheterization (For Kids)

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Educators Search English Español Cardiac Catheterization KidsHealth / For Kids / Cardiac Catheterization What's in this article? What Is ...

  5. Canada's helium output rising fast

    Energy Technology Data Exchange (ETDEWEB)

    1966-12-01

    About 12 months from now, International Helium Limited will be almost ready to start up Canada's second helium extraction plant at Mankota, in Saskatchewan's Wood Mountain area about 100 miles southwest of Moose Jaw. Another 80 miles north is Saskatchewan's (and Canada's) first helium plant, operated by Canadian Helium and sitting on a gas deposit at Wilhelm, 9 miles north of Swift Current. It contains almost 2% helium, some COD2U, and the rest nitrogen. One year in production was apparently enough to convince Canadian Helium that the export market (it sells most of its helium in W. Europe) can take a lot more than it's getting. Construction began this summer on an addition to the Swift Current plant that will raise its capacity from 12 to 36MMcf per yr when it goes on stream next spring. Six months later, International Helium's 40 MMcf per yr plant to be located about 4 miles from its 2 Wood Mountain wells will double Canada's helium output again.

  6. CARDIAC LYMPHOMA IN DOG

    Directory of Open Access Journals (Sweden)

    G. D. Cruz

    2016-11-01

    Full Text Available Lymphoma is a lymphoid tumor that originates in hematopoietic organs such as lymph node, spleen or liver. In dogs, the overall prevalence of cardiac tumors was estimated to be only 0.19% based on the results of the survey of a large database, and lymphomas accounts for approximately 2% of all cardiac tumors. In general, the involvement of the myocardium is rarely described in canine lymphoma. Currently, there is no evidence of a viral association with primary cardiac lymphoma in dogs, but other types of immunosuppression may contribute to abnormal events, such as involvement primary cardiac. The aim of this study was to analyze a case of sudden death of a bitch, SRD, aged 10, who had the final diagnosis of cardiac lymphoma.

  7. Mathematical cardiac electrophysiology

    CERN Document Server

    Colli Franzone, Piero; Scacchi, Simone

    2014-01-01

    This book covers the main mathematical and numerical models in computational electrocardiology, ranging from microscopic membrane models of cardiac ionic channels to macroscopic bidomain, monodomain, eikonal models and cardiac source representations. These advanced multiscale and nonlinear models describe the cardiac bioelectrical activity from the cell level to the body surface and are employed in both the direct and inverse problems of electrocardiology. The book also covers advanced numerical techniques needed to efficiently carry out large-scale cardiac simulations, including time and space discretizations, decoupling and operator splitting techniques, parallel finite element solvers. These techniques are employed in 3D cardiac simulations illustrating the excitation mechanisms, the anisotropic effects on excitation and repolarization wavefronts, the morphology of electrograms in normal and pathological tissue and some reentry phenomena. The overall aim of the book is to present rigorously the mathematica...

  8. Biomaterials for cardiac regeneration

    CERN Document Server

    Ruel, Marc

    2015-01-01

    This book offers readers a comprehensive biomaterials-based approach to achieving clinically successful, functionally integrated vasculogenesis and myogenesis in the heart. Coverage is multidisciplinary, including the role of extracellular matrices in cardiac development, whole-heart tissue engineering, imaging the mechanisms and effects of biomaterial-based cardiac regeneration, and autologous bioengineered heart valves. Bringing current knowledge together into a single volume, this book provides a compendium to students and new researchers in the field and constitutes a platform to allow for future developments and collaborative approaches in biomaterials-based regenerative medicine, even beyond cardiac applications. This book also: Provides a valuable overview of the engineering of biomaterials for cardiac regeneration, including coverage of combined biomaterials and stem cells, as well as extracellular matrices Presents readers with multidisciplinary coverage of biomaterials for cardiac repair, including ...

  9. Public Investment and Output Performance: Evidence from Nigeria

    Directory of Open Access Journals (Sweden)

    Aregbeyen Omo

    2016-05-01

    Full Text Available This study examined the direct/indirect long-run relationships and dynamic interactions between public investment (PI and output performance in Nigeria using annual data spanning 1970-2010. A macro-econometric model derived from Keynes’ income-expenditure framework was employed. The model was disaggregated into demand and supply sides to trace the direct and indirect effects of PI on aggregate output. The direct supply side effect was assessed using the magnitude of PI multiplier coefficient, while the indirect effect of PI on the demand side was evaluated with marginal propensity to consume, accelerator coefficient and import multiplier. The results showed relatively less strong direct effect of PI on aggregate output, while the indirect effects were stronger with the import multiplier being the most pronounced. This is attributed to declining capital expenditure, poor implementation and low quality of PI projects due to widespread corruption. By and large, we concluded that PI exerted considerable influence on aggregate output.

  10. PREVIMER : Meteorological inputs and outputs

    Science.gov (United States)

    Ravenel, H.; Lecornu, F.; Kerléguer, L.

    2009-09-01

    PREVIMER is a pre-operational system aiming to provide a wide range of users, from private individuals to professionals, with short-term forecasts about the coastal environment along the French coastlines bordering the English Channel, the Atlantic Ocean, and the Mediterranean Sea. Observation data and digital modelling tools first provide 48-hour (probably 96-hour by summer 2009) forecasts of sea states, currents, sea water levels and temperatures. The follow-up of an increasing number of biological parameters will, in time, complete this overview of coastal environment. Working in partnership with the French Naval Hydrographic and Oceanographic Service (Service Hydrographique et Océanographique de la Marine, SHOM), the French National Weather Service (Météo-France), the French public science and technology research institute (Institut de Recherche pour le Développement, IRD), the European Institute of Marine Studies (Institut Universitaire Européen de la Mer, IUEM) and many others, IFREMER (the French public institute fo marine research) is supplying the technologies needed to ensure this pertinent information, available daily on Internet at http://www.previmer.org, and stored at the Operational Coastal Oceanographic Data Centre. Since 2006, PREVIMER publishes the results of demonstrators assigned to limited geographic areas and to specific applications. This system remains experimental. The following topics are covered : Hydrodynamic circulation, sea states, follow-up of passive tracers, conservative or non-conservative (specifically of microbiological origin), biogeochemical state, primary production. Lastly, PREVIMER provides researchers and R&D departments with modelling tools and access to the database, in which the observation data and the modelling results are stored, to undertake environmental studies on new sites. The communication will focus on meteorological inputs to and outputs from PREVIMER. It will draw the lessons from almost 3 years during

  11. The 'icon' of output efficiency

    International Nuclear Information System (INIS)

    Bligh, L.N.; Evans, S.G.; Larcos, G.; Gruenewald, S.M.

    1999-01-01

    Full text: Output efficiency (OE) is a well-validated parameter used in the assessment of hydronephrosis. Current analysis on Microdelta appears to produce few low OE values and occasional inability to produce a result. We sought an OE program which gave a reliable response over the full range of values. The aims of this study were to determine: (1) whether OE results are comparable between two computer systems; (2) a normal range for OE on an ICON; (3) inter-observer reproducibility; and (4) the correlation between the two programs and the residual cortical activity ratio (RCA), an index which assesses tracer washout from the 20 min cortical activity/peak cortical activity. Accordingly, two blinded medical radiation scientists reviewed 41 kidneys (26 native, 15 transplant) and calculated OE for each kidney on the ICON and Microdelta computers The OE on the Microdelta and the ICON had good correspondence (r = 0.6%, SEE = 6.2). The extrapolated normal range for ICON OE was 69-92% (mean 80.9%). The inter-observer reproducibility on the ICON was excellent with a CV of 8.7%. ICON OE and RCA had a strong correlation (r = - 0.77, SEE = 0.09), compared with a weaker correlation for the Microdelta (r = 0.47, SEE = 0.13). Processing on the ICON was almost half that of the Microdelta at 4 min compared with 7 min. We conclude that OE generated by these computer programs has good correlation, an established normal range, excellent interobserver reproducibility, but differing correlation with RCA. The response of the ICON program to low ranges of OE is being investigated further

  12. Endogenous Natural Complement Inhibitor Regulates Cardiac Development

    DEFF Research Database (Denmark)

    Mortensen, Simon A; Skov, Louise L; Kjaer-Sorensen, Kasper

    2017-01-01

    mechanisms during fetal development and adult homeostasis. In this article, we describe the function of an endogenous complement inhibitor, mannan-binding lectin (MBL)-associated protein (MAp)44, in regulating the composition of a serine protease-pattern recognition receptor complex, MBL-associated serine...... of MAp44 caused impaired cardiogenesis, lowered heart rate, and decreased cardiac output. These defects were associated with aberrant neural crest cell behavior. We found that MAp44 competed with MASP-3 for pattern recognition molecule interaction, and knockdown of endogenous MAp44 expression could...... be rescued by overexpression of wild-type MAp44. Our observations provide evidence that immune molecules are centrally involved in the orchestration of cardiac tissue development....

  13. Contribution of cardiac and extra-cardiac disease burden to risk of cardiovascular outcomes varies by ejection fraction in heart failure

    DEFF Research Database (Denmark)

    Wolsk, Emil; Claggett, Brian; Køber, Lars

    2018-01-01

    AIMS: Patients with heart failure (HF) often have multiple co-morbidities that contribute to the risk of adverse cardiovascular (CV) and non-CV outcomes. We assessed the relative contribution of cardiac and extra-cardiac disease burden and demographic factors to CV outcomes in HF patients...... Association class, systolic blood pressure, time since HF diagnosis, HF medication use), extra-cardiac (body mass index, creatinine, diabetes mellitus, chronic obstructive pulmonary disease, smoker), and demographic (age, gender) categories, and calculated subscores for each patient representing the burden......EF patients (PAR: 76% cardiac disease vs. 58% extra-cardiac disease, P vs. 49% extra-cardiac disease, P

  14. Biomarkers of Cardiac Stress and Injury in Athletes: What Do They Mean?

    Science.gov (United States)

    Donnellan, Eoin; Phelan, Dermot

    2018-04-01

    Markers of myocardial stress, including troponin, creatine kinase, and brain natriuretic peptide are frequently elevated after endurance athletic pursuits. Here, we summarize the current literature pertaining to the potential mechanism of cardiac enzyme release in athletes and seek to determine the clinical implications of these findings. Recent studies have highlighted the potential adverse cardiac effects of long-term extreme endurance exercise. While troponin release occurs in a pattern distinct from ischemic damage, BNP release has been correlated with right ventricular dysfunction and is likely related to wall stress from prolonged increases in cardiac output. Higher intensity pre-race training regimes are associated with lower race-day enzyme release. While the holistic benefits of regular moderate exercise are indisputable, recent studies have raised concerns about the potential risks of extreme endurance exercise. Release of serum biomarkers suggesting myocardial damage was first described in the 1970s, yet our understanding of the implications of these findings remains incomplete. The mechanisms of release are complex but appear to be primarily physiological phenomena rather than pathologic.

  15. Energy and output dynamics in Bangladesh

    International Nuclear Information System (INIS)

    Paul, Biru Paksha; Uddin, Gazi Salah

    2011-01-01

    The relationship between energy consumption and output is still ambiguous in the existing literature. The economy of Bangladesh, having spectacular output growth and rising energy demand as well as energy efficiency in recent decades, can be an ideal case for examining energy-output dynamics. We find that while fluctuations in energy consumption do not affect output fluctuations, movements in output inversely affect movements in energy use. The results of Granger causality tests in this respect are consistent with those of innovative accounting that includes variance decompositions and impulse responses. Autoregressive distributed lag models also suggest a role of output in Bangladesh's energy use. Hence, the findings of this study have policy implications for other developing nations where measures for energy conservation and efficiency can be relevant in policymaking.

  16. Protective Effect of Peroxisome Proliferator-Activated Receptor α Activation against Cardiac Ischemia-Reperfusion Injury Is Related to Upregulation of Uncoupling Protein-3

    Directory of Open Access Journals (Sweden)

    Jong Wook Song

    2016-01-01

    Full Text Available Activation of peroxisome proliferator-activated receptor α (PPARα confers cardioprotection, while its mechanism remains elusive. We investigated the protective effect of PPARα activation against cardiac ischemia-reperfusion injury in terms of the expression of uncoupling protein (UCP. Myocardial infarct size and UCP expression were measured in rats treated with WY-14643 20 mg/kg, a PPARα ligand, or vehicle. WY-14643 increased UCP3 expression in vivo. Myocardial infarct size was decreased in the WY-14643 group (76 ± 8% versus 42 ± 12%, P<0.05. During reperfusion, the incidence of arrhythmia was higher in the control group compared with the WY-14643 group (9/10 versus 3/10, P<0.05. H9c2 cells were incubated for 24 h with WY-14643 or vehicle. WY-14643 increased UCP3 expression in H9c2 cells. WY-14643 decreased hypoxia-stimulated ROS production. Cells treated with WY-14643 were more resistant to hypoxia-reoxygenation than the untreated cells. Knocking-down UCP3 by siRNA prevented WY-14643 from attenuating the production of ROS. UCP3 siRNA abolished the effect of WY-14643 on cell viability against hypoxia-reoxygenation. In summary, administration of PPARα agonist WY-14643 mitigated the extent of myocardial infarction and incidence of reperfusion-induced arrhythmia. PPARα activation conferred cytoprotective effect against hypoxia-reoxygenation. Associated mechanisms involved increased UCP3 expression and resultant attenuation of ROS production.

  17. Patients’ attitudes and perceptions of two health-related quality-of-life questionnaires used to collect patient-reported outcome measures in the English National Health Service: A qualitative study of patients undergoing cardiac interventions

    Directory of Open Access Journals (Sweden)

    Bashir M Matata

    2013-09-01

    Full Text Available Objectives: To explore patients’ views on the EuroQol-5D and Coronary Revascularisation Outcome Questionnaire, tools currently used for collecting patient-reported outcome measures in the English National Health Service. The key questions were as follows: (1 whether patients consider them sensitive enough to detect change in their health after cardiovascular disease interventions and (2 whether they consider the health-related quality-of-life questions as meaningful. Methods: Data were collected on patients’ views using focus groups. We held four focus groups selecting participants on the basis of their baseline and follow-up EuroQol-5D scores. Data were analysed using framework analysis and grounded theory. Results: Focus group participants confirmed that they had derived substantial health benefits from their cardiac interventions despite the lack of measurable effects on the EuroQol-5D scores. Participants felt that the EuroQol-5D questionnaire was limited because of the following reasons: Their health fluctuates from day to day. They had difficulty assessing their general health status on the visual analogue scale. They felt that the Coronary Revascularisation Outcome Questionnaire was limited because of the following reasons: They did not understand the clinical terms used. The impact of tiredness on their quality of life was not captured. They were unable to distinguish between the effects of their heart condition and other health issues. Additionally, neither questionnaire considers the adjustments people have made to their domestic arrangements to improve their health-related quality of life. Conclusion: This study provides evidence that the two questionnaires do not capture some aspects of health that patients consider important. Furthermore, the presence of co-morbidities masks the symptoms relating to the heart disease and the effect of their cardiac interventions. Future work on patient-reported outcome measures should consider

  18. Cardiac Catheterization (For Parents)

    Science.gov (United States)

    ... cases, the doctor might call for a cardiac magnetic resonance imaging (MRI) scan or a CAT scan . ... first couple of days. This means no heavy lifting (more than 10 pounds) and no sports. After ...

  19. Cardiac Catheterization (For Teens)

    Science.gov (United States)

    ... doctor may also call for a cardiac MRI (magnetic resonance imaging) scan or a CT (computerized tomography) ... first couple of days. This means no heavy lifting (nothing over 10 pounds) and no sports. After ...

  20. Study on the output factors of asymmetrical rectangular electron beam field

    International Nuclear Information System (INIS)

    Chen Yinghai; Yang Yueqin; Ma Yuhong; Zheng Jin; Zou Lijuan

    2009-01-01

    Objective: To evaluate the variant regularity of the output factors of asymmetrical rectangular electron beam field. Methods: The output factors of three special fields with different applicators and energies were measured by ionization chamber method at different off-axis distances. Then deviations of the output factors between asymmetrical and symmetric rectangular fields were calculated. Results: The changes of output factor with different off-axis distances in asymmetrical rectangular fields were basically consistent with those in standard square fields with the same applicator. It revealed that the output factor of asymmetrical rectangular field was related with the off-axis ratio of standard square field. Applicator and field size did not show obvious influence on the output factor. Conclusions: The output factor changes of asymmetrical rectangular field are mainly correlated with the off-axis ratio of standard square field. The correction of the output factor is determined by the off-axis ratio changes in standard square field. (authors)

  1. PDE1C deficiency antagonizes pathological cardiac remodeling and dysfunction

    Science.gov (United States)

    Knight, Walter E.; Chen, Si; Zhang, Yishuai; Oikawa, Masayoshi; Wu, Meiping; Zhou, Qian; Miller, Clint L.; Cai, Yujun; Mickelsen, Deanne M.; Moravec, Christine; Small, Eric M.; Abe, Junichi; Yan, Chen

    2016-01-01

    Cyclic nucleotide phosphodiesterase 1C (PDE1C) represents a major phosphodiesterase activity in human myocardium, but its function in the heart remains unknown. Using genetic and pharmacological approaches, we studied the expression, regulation, function, and underlying mechanisms of PDE1C in the pathogenesis of cardiac remodeling and dysfunction. PDE1C expression is up-regulated in mouse and human failing hearts and is highly expressed in cardiac myocytes but not in fibroblasts. In adult mouse cardiac myocytes, PDE1C deficiency or inhibition attenuated myocyte death and apoptosis, which was largely dependent on cyclic AMP/PKA and PI3K/AKT signaling. PDE1C deficiency also attenuated cardiac myocyte hypertrophy in a PKA-dependent manner. Conditioned medium taken from PDE1C-deficient cardiac myocytes attenuated TGF-β–stimulated cardiac fibroblast activation through a mechanism involving the crosstalk between cardiac myocytes and fibroblasts. In vivo, cardiac remodeling and dysfunction induced by transverse aortic constriction, including myocardial hypertrophy, apoptosis, cardiac fibrosis, and loss of contractile function, were significantly attenuated in PDE1C-knockout mice relative to wild-type mice. These results indicate that PDE1C activation plays a causative role in pathological cardiac remodeling and dysfunction. Given the continued development of highly specific PDE1 inhibitors and the high expression level of PDE1C in the human heart, our findings could have considerable therapeutic significance. PMID:27791092

  2. Cardiac MRI in restrictive cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, A. [Department of Cardiovascular Radiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India); Singh Gulati, G., E-mail: gulatigurpreet@rediffmail.com [Department of Cardiovascular Radiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India); Seth, S. [Department of Cardiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India); Sharma, S. [Department of Cardiovascular Radiology, All India Institute of Medical Sciences, Ansari Nagar, Delhi (India)

    2012-02-15

    Restrictive cardiomyopathy (RCM) is a specific group of heart muscle disorders characterized by inadequate ventricular relaxation during diastole. This leads to diastolic dysfunction with relative preservation of systolic function. Although short axis systolic function is usually preserved in RCM, the long axis systolic function may be severely impaired. Confirmation of diagnosis and information regarding aetiology, extent of myocardial damage, and response to treatment requires imaging. Importantly, differentiation from constrictive pericarditis (CCP) is needed, as only the latter is managed surgically. Echocardiography is the initial cardiac imaging technique but cannot reliably suggest a tissue diagnosis; although recent advances, especially tissue Doppler imaging and spectral tracking, have improved its ability to differentiate RCM from CCP. Cardiac catheterization is the reference standard, but is invasive, two-dimensional, and does not aid myocardial characterization. Cardiac magnetic resonance (CMR) is a versatile technique providing anatomical, morphological and functional information. In recent years, it has been shown to provide important information regarding disease mechanisms, and also been found useful to guide treatment, assess its outcome and predict patient prognosis. This review describes the CMR features of RCM, appearances in various diseases, its overall role in patient management, and how it compares with other imaging techniques.

  3. Cardiac imaging in adults

    International Nuclear Information System (INIS)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority

  4. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  5. Cardiac biomarkers in Neonatology

    OpenAIRE

    Vijlbrief, D.C.

    2015-01-01

    In this thesis, the role for cardiac biomarkers in neonatology was investigated. Several clinically relevant results were reported. In term and preterm infants, hypoxia and subsequent adaptation play an important role in cardiac biomarker elevation. The elevated natriuretic peptides are indicative of abnormal function; elevated troponins are suggestive for cardiomyocyte damage. This methodology makes these biomarkers of additional value in the treatment of newborn infants, separate or as a co...

  6. Post cardiac injury syndrome

    DEFF Research Database (Denmark)

    Nielsen, S L; Nielsen, F E

    1991-01-01

    The post-pericardiotomy syndrome is a symptom complex which is similar in many respects to the post-myocardial infarction syndrome and these are summarized under the diagnosis of the Post Cardiac Injury Syndrome (PCIS). This condition, which is observed most frequently after open heart surgery, i...... on the coronary vessels, with cardiac tamponade and chronic pericardial exudate. In the lighter cases, PCIS may be treated with NSAID and, in the more severe cases, with systemic glucocorticoid which has a prompt effect....

  7. Impact of thoracic surgery on cardiac morphology and function in small animal models of heart disease: a cardiac MRI study in rats.

    Directory of Open Access Journals (Sweden)

    Peter Nordbeck

    Full Text Available BACKGROUND: Surgical procedures in small animal models of heart disease might evoke alterations in cardiac morphology and function. The aim of this study was to reveal and quantify such potential artificial early or long term effects in vivo, which might account for a significant bias in basic cardiovascular research, and, therefore, could potentially question the meaning of respective studies. METHODS: Female Wistar rats (n = 6 per group were matched for weight and assorted for sham left coronary artery ligation or control. Cardiac morphology and function was then investigated in vivo by cine magnetic resonance imaging at 7 Tesla 1 and 8 weeks after the surgical procedure. The time course of metabolic and inflammatory blood parameters was determined in addition. RESULTS: Compared to healthy controls, rats after sham surgery showed a lower body weight both 1 week (267.5±10.6 vs. 317.0±11.3 g, n<0.05 and 8 weeks (317.0±21.1 vs. 358.7±22.4 g, n<0.05 after the intervention. Left and right ventricular morphology and function were not different in absolute measures in both groups 1 week after surgery. However, there was a confined difference in several cardiac parameters normalized to the body weight (bw, such as myocardial mass (2.19±0.30/0.83±0.13 vs. 1.85±0.22/0.70±0.07 mg left/right per g bw, p<0.05, or enddiastolic ventricular volume (1.31±0.36/1.21±0.31 vs. 1.14±0.20/1.07±0.17 µl left/right per g bw, p<0.05. Vice versa, after 8 weeks, cardiac masses, volumes, and output showed a trend for lower values in sham operated rats compared to controls in absolute measures (782.2±57.2/260.2±33.2 vs. 805.9±84.8/310.4±48.5 mg, p<0.05 for left/right ventricular mass, but not normalized to body weight. Matching these findings, blood testing revealed only minor inflammatory but prolonged metabolic changes after surgery not related to cardiac disease. CONCLUSION: Cardio-thoracic surgical procedures in experimental myocardial infarction

  8. Acute alteration of cardiac ECG, action potential, I{sub Kr} and the human ether-a-go-go-related gene (hERG) K{sup +} channel by PCB 126 and PCB 77

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi-Hyeong; Park, Won Sun; Jo, Su-Hyun, E-mail: suhyunjo@kangwon.ac.kr

    2012-07-01

    Polychlorinated biphenyls (PCBs) have been known as serious persistent organic pollutants (POPs), causing developmental delays and motor dysfunction. We have investigated the effects of two PCB congeners, 3,3′,4,4′-tetrachlorobiphenyl (PCB 77) and 3,3′,4,4′,5-pentachlorobiphenyl (PCB 126) on ECG, action potential, and the rapidly activating delayed rectifier K{sup +} current (I{sub Kr}) of guinea pigs' hearts, and hERG K{sup +} current expressed in Xenopus oocytes. PCB 126 shortened the corrected QT interval (QTc) of ECG and decreased the action potential duration at 90% (APD{sub 90}), and 50% of repolarization (APD{sub 50}) (P < 0.05) without changing the action potential duration at 20% (APD{sub 20}). PCB 77 decreased APD{sub 20} (P < 0.05) without affecting QTc, APD{sub 90}, and APD{sub 50}. The PCB 126 increased the I{sub Kr} in guinea-pig ventricular myocytes held at 36 °C and hERG K{sup +} current amplitude at the end of the voltage steps in voltage-dependent mode (P < 0.05); however, PCB 77 did not change the hERG K{sup +} current amplitude. The PCB 77 increased the diastolic Ca{sup 2+} and decreased Ca{sup 2+} transient amplitude (P < 0.05), however PCB 126 did not change. The results suggest that PCB 126 shortened the QTc and decreased the APD{sub 90} possibly by increasing I{sub Kr}, while PCB 77 decreased the APD{sub 20} possibly by other modulation related with intracellular Ca{sup 2+}. The present data indicate that the environmental toxicants, PCBs, can acutely affect cardiac electrophysiology including ECG, action potential, intracellular Ca{sup 2+}, and channel activity, resulting in toxic effects on the cardiac function in view of the possible accumulation of the PCBs in human body. -- Highlights: ► PCBs are known as serious environmental pollutants and developmental disruptors. ► PCB 126 shortened QT interval of ECG and action potential duration. ► PCB 126 increased human ether-a-go-go-related K{sup +} current and I{sub Kr}.

  9. Social networks and research output

    NARCIS (Netherlands)

    Ductor, L.; Fafchamps, M.; Goyal, S.; van der Leij, M.J.

    2014-01-01

    We study how knowledge about the social network of an individual researcher - as embodied in his coauthor relations - helps us in developing a more accurate prediction of his future productivity. We find that incorporating information about coauthor networks leads to a modest improvement in the

  10. Functional genetic polymorphisms in CYP2C19 gene in relation to cardiac side effects and treatment dose in a methadone maintenance cohort.

    Science.gov (United States)

    Wang, Sheng-Chang; Ho, Ing-Kang; Tsou, Hsiao-Hui; Liu, Sheng-Wen; Hsiao, Chin-Fu; Chen, Chia-Hui; Tan, Happy Kuy-Lok; Lin, Linen; Wu, Chi-Shin; Su, Lien-Wen; Huang, Chieh-Liang; Yang, Yi-Hong; Liu, Ming-Lun; Lin, Keh-Ming; Liu, Shu Chih; Wu, Hsiao-Yu; Kuo, Hsiang-Wei; Chen, Andrew C H; Chang, Yao-Sheng; Liu, Yu-Li

    2013-10-01

    Abstract Methadone maintenance therapy is an established treatment for heroin dependence. This study tested the influence of functional genetic polymorphisms in CYP2C19 gene encoding a CYP450 enzyme that contributes to methadone metabolism on treatment dose, plasma concentration, and side effects of methadone. Two single nucleotide polymorphisms (SNPs), rs4986893 (exon 4) and rs4244285 (exon 5), were selected and genotyped in 366 patients receiving methadone maintenance therapy in Taiwan. The steady-state plasma concentrations of both methadone and its EDDP metabolite enantiomers were measured. SNP rs4244285 allele was significantly associated with the corrected QT interval (QTc) change in the electrocardiogram (p=0.021), and the Treatment Emergent Symptom Scale (TESS) total score (p=0.021) in patients who continued using heroin, as demonstrated with a positive urine opiate test. Using the gene dose (GD) models where the CYP2C19 SNPs were clustered into poor (0 GD) versus intermediate (1 GD) and extensive (2 GD) metabolizers, we found that the extensive metabolizers required a higher dose of methadone (p=0.035), and showed a lower plasma R-methadone/methadone dose ratio (p=0.007) in urine opiate test negative patients, as well as a greater QTc change (p=0.008) and higher total scores of TESS (p=0.018) in urine opiate test positive patients, than poor metabolizers. These results in a large study sample from Taiwan suggest that the gene dose of CYP2C19 may potentially serve as an indicator for the plasma R-methadone/methadone dose ratio and cardiac side effect in patients receiving methadone maintenance therapy. Further studies of pharmacogenetic variation in methadone pharmacokinetics and pharmacodynamics are warranted in different world populations.

  11. Direct Cardiac Reprogramming: Advances in Cardiac Regeneration

    Directory of Open Access Journals (Sweden)

    Olivia Chen

    2015-01-01

    Full Text Available Heart disease is one of the lead causes of death worldwide. Many forms of heart disease, including myocardial infarction and pressure-loading cardiomyopathies, result in irreversible cardiomyocyte death. Activated fibroblasts respond to cardiac injury by forming scar tissue, but ultimately this response fails to restore cardiac function. Unfortunately, the human heart has little regenerative ability and long-term outcomes following acute coronary events often include chronic and end-stage heart failure. Building upon years of research aimed at restoring functional cardiomyocytes, recent advances have been made in the direct reprogramming of fibroblasts toward a cardiomyocyte cell fate both in vitro and in vivo. Several experiments show functional improvements in mouse models of myocardial infarction following in situ generation of cardiomyocyte-like cells from endogenous fibroblasts. Though many of these studies are in an early stage, this nascent technology holds promise for future applications in regenerative medicine. In this review, we discuss the history, progress, methods, challenges, and future directions of direct cardiac reprogramming.

  12. DIST/AVC Out-Put Definition.

    Science.gov (United States)

    Wilkinson, Gene L.

    The first stage of development of a management information system for DIST/AVC (Division of Instructional Technology/Audio-Visual Center) is the definition of out-put units. Some constraints on the definition of output units are: 1) they should reflect goals of the organization, 2) they should reflect organizational structure and procedures, and…

  13. Fast multi-output relevance vector regression

    OpenAIRE

    Ha, Youngmin

    2017-01-01

    This paper aims to decrease the time complexity of multi-output relevance vector regression from O(VM^3) to O(V^3+M^3), where V is the number of output dimensions, M is the number of basis functions, and V

  14. Early-Transition Output Decline Revisited

    Directory of Open Access Journals (Sweden)

    Crt Kostevc

    2016-05-01

    Full Text Available In this paper we revisit the issue of aggregate output decline that took place in the early transition period. We propose an alternative explanation of output decline that is applicable to Central- and Eastern-European countries. In the first part of the paper we develop a simple dynamic general equilibrium model that builds on work by Gomulka and Lane (2001. In particular, we consider price liberalization, interpreted as elimination of distortionary taxation, as a trigger of the output decline. We show that price liberalization in interaction with heterogeneous adjustment costs and non-employment benefits lead to aggregate output decline and surge in wage inequality. While these patterns are consistent with actual dynamics in CEE countries, this model cannot generate output decline in all sectors. Instead sectors that were initially taxed even exhibit output growth. Thus, in the second part we consider an alternative general equilibrium model with only one production sector and two types of labor and distortion in a form of wage compression during the socialist era. The trigger for labor mobility and consequently output decline is wage liberalization. Assuming heterogeneity of workers in terms of adjustment costs and non-employment benefits can explain output decline in all industries.

  15. Assessing the psychological factors predicting workers' output ...

    African Journals Online (AJOL)

    The study investigated job security, communication skills, interpersonal relationship and emotional intelligence as correlates of workers' output among local government employees in Oyo State. The research adopted descriptive design of an expose facto type. The research instruments used includes Workers' output scale, ...

  16. Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients

    DEFF Research Database (Denmark)

    Møller-Sørensen, Hasse; Cordtz, Joakim; Østergaard, Morten

    2017-01-01

    completed the study. Each patient were placed in the following successive positions: (1) supine, (2) head-down tilt, (3) head-up tilt, (4) supine, (5) supine with phenylephrine administration, (6) pace heart rate 80 beats per minute (bpm), (7) pace heart rate 110 bpm. The agreement of compared data...

  17. Scoring of late gadolinium enhancement in cardiac magnetic resonance imaging can predict cardiac events in patients with hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Nojiri, Ayumi; Hongo, Kenichi; Kawai, Makoto; Komukai, Kimiaki; Sakuma, Toru; Taniguchi, Ikuo; Yoshimura, Michihiro

    2011-01-01

    Late gadolinium enhancement (LGE) of cardiac magnetic resonance imaging (MRI) represents myocardial fibrosis and may be related to the clinical outcome of various heart diseases. This study evaluated the relationship between LGE and cardiac events in hypertrophic cardiomyopathy (HCM) using a new scoring method. This study retrospectively followed 46 HCM patients without heart failure symptoms for 3.8±1.8 years. Gadolinium-enhanced cardiac MRI was performed in all patients. Cardiac events including newly developed heart failure or ventricular tachyarrhythmia were evaluated during the follow-up period. We evaluated the predictive factors to identify the patients with cardiac events. None of the risk factors reported to be related to poor outcome or the existence of LGE alone could predict cardiac events, which might be due to the small number of subjects investigated in this study. A new scoring method for LGE-positive areas (LGE score) was applied and higher LGE score can predict cardiac events in this study population. The proposed LGE score for cardiac MRI is considered to be a potentially valid method for assessing cardiac events in HCM patients. (author)

  18. Reducing variability in the output of pattern classifiers using histogram shaping

    International Nuclear Information System (INIS)

    Gupta, Shalini; Kan, Chih-Wen; Markey, Mia K.

    2010-01-01

    Purpose: The authors present a novel technique based on histogram shaping to reduce the variability in the output and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs. Methods: The authors identify different sources of variability in the output of linear pattern classifiers with identical ROC curves, which also result in classifiers with differently distributed outputs. They theoretically develop a novel technique based on the matching of the histograms of these differently distributed pattern classifier outputs to reduce the variability in their (sensitivity, specificity) pairs at fixed decision thresholds, and to reduce the variability in their actual output values. They empirically demonstrate the efficacy of the proposed technique by means of analyses on the simulated data and real world mammography data. Results: For the simulated data, with three different known sources of variability, and for the real world mammography data with unknown sources of variability, the proposed classifier output calibration technique significantly reduced the variability in the classifiers' (sensitivity, specificity) pairs at fixed decision thresholds. Furthermore, for classifiers with monotonically or approximately monotonically related output variables, the histogram shaping technique also significantly reduced the variability in their actual output values. Conclusions: Classifier output calibration based on histogram shaping can be successfully employed to reduce the variability in the output values and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs.

  19. Input-output theory and institutional aspects of environmental policy

    NARCIS (Netherlands)

    Steenge, A.E.

    1999-01-01

    National accounting over the years has developed in close interaction with input–output analysis. However, present developments involving core and satellite accounts seem to suggest that this relation will become less close, with possible negative consequences for analysis and policy. In this paper

  20. [The impact of weight management and related diuretic medication intervention based on body weight changes on cardiac function and re-hospitalization rate in patients with chronic congestive heart failure].

    Science.gov (United States)

    Wang, F W; Shi, J; Shi, J; Yang, J W; Wang, Z H; Ye, J H; Ye, Y; Zheng, H Q; Huang, J

    2017-10-24

    Objective: To explore the impact of weight management and related medication intervention based on body weight changes on cardiac function among patients with chronic congestive heart failure (CHF). Methods: Using prospective, randomized, controlled study methods, consecutive CHF patients, who hospitalized in our department from June 2014 to June 2016 ( n =350), were randomly divided into intervention group ( n =175) and control group ( n =175). Patients in the intervention group received weight management guidance and the post discharge diuretic drugs regimen was adjusted based on body weight changes. The control group received routine medical care post discharge. Left ventricular ejection fraction (LVEF), B type natriuretic peptide precursor (NT-proBNP), 6 minutes walk distance and NYHA classification at one day before discharge and after 6 months were compared between the two groups respectively. Results: Follow-up visit data were not available from 6 patients in the control and intervention group respectively. NYHA classification, LVEF, NT-proBNP and 6 minutes walk distance were similar between the two groups at one day before discharge (all P >0.05). After 6 months, the LVEF and 6 minutes walk distance were significantly higher while NT-proBNP level was significantly lower in the intervention group compared to the control group (all P weight remained unchanged in the intervention group, while body weight tended to be higher in the control group compared to one day before discharge. Conclusion: The weight management and diuretic drug regimen adjudgment intervention based on body weight changes can improve cardiac function and reduced re-hospitalization rate in CHF patients.

  1. Buck supplies output voltage ripple reduction using fuzzy control

    Directory of Open Access Journals (Sweden)

    Nicu BIZON

    2007-12-01

    Full Text Available Using the PWM control for switching power supplies the peaks EMI noise appear at the switching frequency and its harmonics. Using randomize or chaotic PWM control techniques in these systems the power spectrum is spread out in all frequencies band spectral emissions, but with a bigger ripple in the output voltage. The proposed nonlinear feedback control method, which induces chaos, is based by fuzzy rules that minimize the output voltage ripple. The feasibility and effectiveness of this relative simple method is shown by simulation. A comparison with the previous control method is included, too.

  2. Biomarkers for cardiac cachexia: reality or utopia.

    Science.gov (United States)

    Martins, Telma; Vitorino, Rui; Amado, Francisco; Duarte, José Alberto; Ferreira, Rita

    2014-09-25

    Cardiac cachexia is a serious complication of chronic heart failure, characterized by significant weight loss and body wasting. Chronic heart failure-related muscle wasting results from a chronic imbalance in the activation of anabolic or catabolic pathways, caused by a series of immunological, metabolic, and neurohormonal processes. In spite of the high morbidity and mortality associated to this condition, there is no universally accepted definition or specific biomarkers for cardiac cachexia, which makes its diagnosis and treatment difficult. Several hormonal, inflammatory and oxidative stress molecules have been proposed as serological markers of prognosis in cardiac cachexia but with doubtful success. As individual biomarkers may have limited sensitivity and specificity, multimarker strategies involving mediators of the biological processes modulated by cardiac cachexia will strongly contribute for the diagnosis and management of the disease, as well as for the establishment of new therapeutic targets. An integrated analysis of the biomarkers proposed so far for cardiac cachexia is made in the present review, highlighting the biological processes to which they are related. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Ventilation and gas exchange management after cardiac arrest.

    Science.gov (United States)

    Sutherasan, Yuda; Raimondo, Pasquale; Pelosi, Paolo

    2015-12-01

    For several decades, physicians had integrated several interventions aiming to improve the outcomes in post-cardiac arrest patients. However, the mortality rate after cardiac arrest is still as high as 50%. Post-cardiac arrest syndrome is associated with high morbidity and mortality due to not only poor neurological outcome and cardiovascular failure but also respiratory dysfunction. To minimize ventilator-associated lung injury, protective mechanical ventilation by using low tidal volume ventilation and driving pressure may decrease pulmonary complications and improve survival. Low level of positive end-expiratory pressure (PEEP) can be initiated and titrated with careful cardiac output and respiratory mechanics monitoring. Furthermore, optimizing gas exchange by avoiding hypoxia and hyperoxia as well as maintaining normocarbia may improve neurological and survival outcome. Early multidisciplinary cardiac rehabilitation intervention is recommended. Minimally invasive monitoring techniques, that is, echocardiography, transpulmonary thermodilution method measuring extravascular lung water, as well as transcranial Doppler ultrasound, might be useful to improve appropriate management of post-cardiac arrest patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Cardiac radiology: centenary review.

    Science.gov (United States)

    de Roos, Albert; Higgins, Charles B

    2014-11-01

    During the past century, cardiac imaging technologies have revolutionized the diagnosis and treatment of acquired and congenital heart disease. Many important contributions to the field of cardiac imaging were initially reported in Radiology. The field developed from the early stages of cardiac imaging, including the use of coronary x-ray angiography and roentgen kymography, to nowadays the widely used echocardiographic, nuclear medicine, cardiac computed tomographic (CT), and magnetic resonance (MR) applications. It is surprising how many of these techniques were not recognized for their potential during their early inception. Some techniques were described in the literature but required many years to enter the clinical arena and presently continue to expand in terms of clinical application. The application of various CT and MR contrast agents for the diagnosis of myocardial ischemia is a case in point, as the utility of contrast agents continues to expand the noninvasive characterization of myocardium. The history of cardiac imaging has included a continuous process of advances in our understanding of the anatomy and physiology of the cardiovascular system, along with advances in imaging technology that continue to the present day.

  5. High Output Piezo/Triboelectric Hybrid Generator

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-03-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA.cm-2, and average power density of ~4.44 mW.cm-2. The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics.

  6. High Output Piezo/Triboelectric Hybrid Generator

    Science.gov (United States)

    Jung, Woo-Suk; Kang, Min-Gyu; Moon, Hi Gyu; Baek, Seung-Hyub; Yoon, Seok-Jin; Wang, Zhong-Lin; Kim, Sang-Woo; Kang, Chong-Yun

    2015-01-01

    Recently, piezoelectric and triboelectric energy harvesting devices have been developed to convert mechanical energy into electrical energy. Especially, it is well known that triboelectric nanogenerators have a simple structure and a high output voltage. However, whereas nanostructures improve the output of triboelectric generators, its fabrication process is still complicated and unfavorable in term of the large scale and long-time durability of the device. Here, we demonstrate a hybrid generator which does not use nanostructure but generates much higher output power by a small mechanical force and integrates piezoelectric generator into triboelectric generator, derived from the simultaneous use of piezoelectric and triboelectric mechanisms in one press-and-release cycle. This hybrid generator combines high piezoelectric output current and triboelectric output voltage, which produces peak output voltage of ~370 V, current density of ~12 μA·cm−2, and average power density of ~4.44 mW·cm−2. The output power successfully lit up 600 LED bulbs by the application of a 0.2 N mechanical force and it charged a 10 μF capacitor to 10 V in 25 s. Beyond energy harvesting, this work will provide new opportunities for developing a small, built-in power source in self-powered electronics such as mobile electronics. PMID:25791299

  7. Neurologic Function and Health-Related Quality of Life in Patients Following Targeted Temperature Management at 33°C vs 36°C After Out-of-Hospital Cardiac Arrest: A Randomized Clinical Trial

    NARCIS (Netherlands)

    Cronberg, Tobias; Lilja, Gisela; Horn, Janneke; Kjaergaard, Jesper; Wise, Matt P.; Pellis, Tommaso; Hovdenes, Jan; Gasche, Yvan; Åneman, Anders; Stammet, Pascal; Erlinge, David; Friberg, Hans; Hassager, Christian; Kuiper, Michael; Wanscher, Michael; Bosch, Frank; Cranshaw, Julius; Kleger, Gian-Reto; Persson, Stefan; Undén, Johan; Walden, Andrew; Winkel, Per; Wetterslev, Jørn; Nielsen, Niklas

    2015-01-01

    Brain injury affects neurologic function and quality of life in survivors after cardiac arrest. To compare the effects of 2 target temperature regimens on long-term cognitive function and quality of life after cardiac arrest. In this multicenter, international, parallel group, assessor-masked

  8. Factors influencing the development of low output state in patients with right ventricular infarction

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Yoichi; Kanno, Kazuji; Saito, Muneyasu; Haze, Kazuo; Sumiyoshi, Tetsuya; Fukami, Kenichi; Fujiwara, Yasushi; Hiramori, Katsuhiko; Ikeda, Masao [National Cardiovascular Center, Suita, Osaka (Japan)

    1984-06-01

    Right ventricular infarction is frequently accompanied by a low output state, but the factors influencing the development of this state remain unknown. To elucidate these factors, clinical findings, hemodynamic findings and left ventricular infarct size (Tl-score) calculated from thallium-201 myocardial scintigrams by a circumferential profile method were evaluated in 147 consecutive patients with acute transmural inferior myocardial infarction. They were divided into two groups: 44 patients with right ventricular involvement (RVI group) and 103 patients without right ventricular involvement (IMI group). A low cardiac output state was defined when the cardiac index was less than 2.2 L/min/M/sup 2/. There was a good correlation between Tl-score and any of peak value of serum creatine phosphokinase (CPKmax), total released CPK (CPKr) and left ventricular ejection fraction (LVEF) (r=o.66, 0.74 and -0.54, respectively), indicating the usefulness of Tl-score as an index of left ventricular damage. Compared to the IMI group, the RVI group showed a higher average of age (p < 0.01), lower systemic blood pressure (p < 0.01), higher right atrial pressure (p < 0.001) and lower cardiac index (p < 0.01). Furthermore, the incidence of a low output state (RVI group:47.7% vs IMI group:14.6%, p < 0.001) and mortality (25.0% vs 7.8%, p < 0.01) were higher in the RVI group. However, CPKmax, CPKr, LVEF and Tl-score, which were considered to reflect the severity of left ventricular damage, were not different between the two groups. Tl-score was inversely correlated with cardiac index in the RVI group (r=-0.49, p < 0.05), and with left ventricular stroke work index in the both groups (RVI group; r=-0.46, p < 0.01, IMI group; r=-0.64, p < 0.01).

  9. Isolated Cardiac Hydatid Cyst

    International Nuclear Information System (INIS)

    Shakil, U.; Rehman, A. U.; Shahid, R.

    2015-01-01

    Hydatid cyst disease is common in our part of the world. Cardiac hydatid cyst is its rare manifestation. We report this case of 48-year male having isolated cardiac hydatid cyst, incidentally found on computed tomography. This patient presented in medical OPD of Combined Military Hospital, Lahore with one month history of mild retrosternal discomfort. His general physical and systemic examinations as well as ECG were unremarkable. Chest X-ray showed an enlarged cardiac shadow with mildly irregular left heart border. Contrast enhanced CT scan of the chest showed a large well defined multiloculated non-enhancing cystic lesion with multiple daughter cysts involving wall of left ventricle and overlying pericardium. Serology for echinococcus confirmed the diagnosis of hydatid cyst. Patient was offered the surgical treatment but he opted for medical treatment only. Albendezol was prescribed. His follow-up echocardiography after one month showed no significant decrease in size of the cyst. (author)

  10. Cardiac rehabilitation costs.

    Science.gov (United States)

    Moghei, Mahshid; Turk-Adawi, Karam; Isaranuwatchai, Wanrudee; Sarrafzadegan, Nizal; Oh, Paul; Chessex, Caroline; Grace, Sherry L

    2017-10-01

    Despite the clinical benefits of cardiac rehabilitation (CR) and its cost-effectiveness, it is not widely received. Arguably, capacity could be greatly increased if lower-cost models were implemented. The aims of this review were to describe: the costs associated with CR delivery, approaches to reduce these costs, and associated implications. Upon finalizing the PICO statement, information scientists were enlisted to develop the search strategy of MEDLINE, Embase, CDSR, Google Scholar and Scopus. Citations identified were considered for inclusion by the first author. Extracted cost data were summarized in tabular format and qualitatively synthesized. There is wide variability in the cost of CR delivery around the world, and patients pay out-of-pocket for some or all of services in 55% of countries. Supervised CR costs in high-income countries ranged from PPP$294 (Purchasing Power Parity; 2016 United States Dollars) in the United Kingdom to PPP$12,409 in Italy, and in middle-income countries ranged from PPP$146 in Venezuela to PPP$1095 in Brazil. Costs relate to facilities, personnel, and session dose. Delivering CR using information and communication technology (mean cost PPP$753/patient/program), lowering the dose and using lower-cost personnel and equipment are important strategies to consider in containing costs, however few explicitly low-cost models are available in the literature. More research is needed regarding the costs to deliver CR in community settings, the cost-effectiveness of CR in most countries, and the economic impact of return-to-work with CR participation. A low-cost model of CR should be standardized and tested for efficacy across multiple healthcare systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Patch in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Alireza Alizadeh Ghavidel

    2014-06-01

    Full Text Available Introduction: Excessive bleeding presents a risk for the patient in cardiovascular surgery. Local haemostatic agents are of great value to reduce bleeding and related complications. TachoSil (Nycomed, Linz, Austria is a sterile, haemostatic agent that consists of an equine collagen patchcoated with human fibrinogen and thrombin. This study evaluated the safety and efficacy of TachoSil compared to conventional technique.Methods: Forty-two patients scheduled for open heart surgeries, were entered to this study from August 2010 to May 2011. After primary haemostatic measures, patients divided in two groups based on surgeon’s judgment. Group A: 20 patients for whom TachoSil was applied and group B: 22 patients that conventional method using Surgicel (13 patients or wait and see method (9 cases, were performed in order to control the bleeding. In group A, 10 patients were male with mean age of 56.95±15.67 years and in group B, 9 cases were male with mean age of 49.95±14.41 years. In case group 70% (14/20 of the surgeries were redo surgeries versus 100% (22/22 in control group.Results: Baseline characteristics were similar in both groups. In TachoSil group 75% of patients required transfusion versus 90.90% in group B (P=0.03.Most transfusions consisted of packed red blood cell; 2±1.13 units in group A versus 3.11±1.44 in group B (P=0.01, however there were no significant differences between two groups regarding the mean total volume of intra and post-operative bleeding. Re-exploration was required in 10% in group A versus 13.63% in group B (P=0.67.Conclusion: TachoSil may act as a superior alternative in different types of cardiac surgery in order to control the bleeding and therefore reducing transfusion requirement.

  12. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  13. Systemic arteriovenous malformations as a cause of cardiac failure: Treatment with embolization

    International Nuclear Information System (INIS)

    Smith, E.J.; Hemingway, A.P.; Allison, D.J.

    1987-01-01

    Massive cogenital systemic arteriovenous malformations (AVMs) present considerable management problems for clinicians. Their size, position, and vascularity make successful surgical reaction impossible. Attempts at resection produce only temporary relief of symptoms and cause further disfigurement. Large AVMs give rise to pain, swelling, and distal ischaemia, can erode bone, and give rise to life-threatening hemorrhage, and a massive left or right shunt causes high-output cardiac failure and death. Ten patients (age range, 5-50 years; mean 26 years) have massive AVMs giving rise to high-output cardiac failure (26-28 liters). These patients (seven male, three female), have undergone a total of 43 embolization procedures. The advent of nonionic contrast media, digital subtraction angiography, steel coils, and balloons allows us to successfully treat these patients who until recently were condemned to die in high-output cardiac failure

  14. Farm-Level Determinants of output Commercialization:

    African Journals Online (AJOL)

    MARC-AB

    Ethiopian Institute of Agricultural Research. አኀፅሮተ- ... haricot bean output commercialization among smallholder farmers in moisture-stress areas of ..... the American Agricultural Economics Association Annual Meeting, Orlando, Florida, July.

  15. Endogenous Money, Output and Prices in India

    OpenAIRE

    Das, Rituparna

    2009-01-01

    This paper proposes to quantify the macroeconometric relationships among the variables broad money, lending by banks, price, and output in India using simultaneous equations system keeping in view the issue of endogeneity.

  16. Scintillation camera with improved output means

    International Nuclear Information System (INIS)

    Lange, K.; Wiesen, E.J.; Woronowicz, E.M.

    1978-01-01

    In a scintillation camera system, the output pulse signals from an array of photomultiplier tubes are coupled to the inputs of individual preamplifiers. The preamplifier output signals are coupled to circuitry for computing the x and y coordinates of the scintillations. A cathode ray oscilloscope is used to form an image corresponding with the pattern in which radiation is emitted by a body. Means for improving the uniformity and resolution of the scintillations are provided. The means comprise biasing means coupled to the outputs of selected preamplifiers so that output signals below a predetermined amplitude are not suppressed and signals falling within increasing ranges of amplitudes are increasingly suppressed. In effect, the biasing means make the preamplifiers non-linear for selected signal levels

  17. Input-output rearrangement of isolated converters

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Kovacevic, Milovan; Mønster, Jakob Døllner

    2015-01-01

    This paper presents a new way of rearranging the input and output of isolated converters. The new arrangement posses several advantages, as increased voltage range, higher power handling capabilities, reduced voltage stress and improved efficiency, for applications where galvanic isolation...

  18. Multiple Input - Multiple Output (MIMO) SAR

    Data.gov (United States)

    National Aeronautics and Space Administration — This effort will research and implement advanced Multiple-Input Multiple-Output (MIMO) Synthetic Aperture Radar (SAR) techniques which have the potential to improve...

  19. Cardiac Anxiety - When the heart is (thought to be) in danger-

    NARCIS (Netherlands)

    Beek, M.H.C.T. van

    2016-01-01

    When the heart is (thought to be) in danger - like after a myocardial infarction (MI) or in patients with Non Cardiac Chest Pain (NCCP)- , this may provoke specific fears related to the heart: cardiac anxiety. This anxiety is often not acknowledged nor treated. The present thesis showed that cardiac

  20. Graphical and statistical techniques for cardiac cycle time (phase) dependent changes in interbeat interval.

    NARCIS (Netherlands)

    Jennings, J.R.; van der Molen, M.W.; Somsen, R.J.M.; Ridderinkhof, K.R.

    1991-01-01

    Cardiac cycle time effects refer to the relative lengthening or shortening of a single cardiac cycle as a function of when in the cycle brief sensorimotor events occur. These effects may provide short-latency measures of cardiac sensitivity to Psychological events. Conventional representations have,