WorldWideScience

Sample records for related fixation failure

  1. Failure analysis of stainless steel femur fixation plate.

    Science.gov (United States)

    Hussain, P B; Mohammad, M

    2004-05-01

    Failure analysis was performed to investigate the failure of the femur fixation plate which was previously fixed on the femur of a girl. Radiography, metallography, fractography and mechanical testing were conducted in this study. The results show that the failure was due to the formation of notches on the femur plate. These notches act as stress raisers from where the cracks start to propagate. Finally fracture occurred on the femur plate and subsequently, the plate failed.

  2. Relative strength of tailor's bunion osteotomies and fixation techniques.

    Science.gov (United States)

    Haddon, Todd B; LaPointe, Stephan J

    2013-01-01

    A paucity of data is available on the mechanical strength of fifth metatarsal osteotomies. The present study was designed to provide that information. Five osteotomies were mechanically tested to failure using a materials testing machine and compared with an intact fifth metatarsal using a hollow saw bone model with a sample size of 10 for each construct. The osteotomies tested were the distal reverse chevron fixated with a Kirschner wire, the long plantar reverse chevron osteotomy fixated with 2 screws, a mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, the mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, and an additional cerclage wire and a transverse closing wedge osteotomy fixated with a box wire technique. Analysis of variance was performed, resulting in a statistically significant difference among the data at p chevron was statistically the strongest construct at 130 N, followed by the long plantar osteotomy at 78 N. The chevron compared well with the control at 114 N, and they both fractured at the proximal model to fixture interface. The other osteotomies were statistically and significantly weaker than both the chevron and the long plantar constructs, with no statistically significant difference among them at 36, 39, and 48 N. In conclusion, the chevron osteotomy was superior in strength to the sagittal and transverse plane osteotomies and similar in strength and failure to the intact model. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. The prediction of cyclic proximal humerus fracture fixation failure by various bone density measures.

    Science.gov (United States)

    Varga, Peter; Grünwald, Leonard; Windolf, Markus

    2018-02-22

    Fixation of osteoporotic proximal humerus fractures has remained challenging, but may be improved by careful pre-operative planning. The aim of this study was to investigate how well the failure of locking plate fixation of osteoporotic proximal humerus fractures can be predicted by bone density measures assessed with currently available clinical imaging (realistic case) and a higher resolution and quality modality (theoretical best-case). Various density measures were correlated to experimentally assessed number of cycles to construct failure of plated unstable low-density proximal humerus fractures (N = 18). The influence of density evaluation technique was investigated by comparing local (peri-implant) versus global evaluation regions; HR-pQCT-based versus clinical QCT-based image data; ipsilateral versus contralateral side; and bone mineral content (BMC) versus bone mineral density (BMD). All investigated density measures were significantly correlated with the experimental cycles to failure. The best performing clinically feasible parameter was the QCT-based BMC of the contralateral articular cap region, providing significantly better correlation (R 2  = 0.53) compared to a previously proposed clinical density measure (R 2  = 0.30). BMC had consistently, but not significantly stronger correlations with failure than BMD. The overall best results were obtained with the ipsilateral HR-pQCT-based local BMC (R 2  = 0.74) that may be used for implant optimization. Strong correlations were found between the corresponding density measures of the two CT image sources, as well as between the two sides. Future studies should investigate if BMC of the contralateral articular cap region could provide improved prediction of clinical fixation failure compared to previously proposed measures. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants

    Directory of Open Access Journals (Sweden)

    Yan Zhou

    2015-10-01

    Full Text Available Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with the evidence of increased surface roughness and embrittlement. Depredated surface of the Ti plate resulted debris particles in the surrounding tissue of 15.2 ± 6.5 μm in size. Nanoparticles were observed in transmission electron microscope. The electron diffraction pattern of the debris indicates a combination of nanocrystalline and amorphous phases. The failure mode of the broken nail made of stainless steel was found to be fatigue initiated from the surface. This study clearly shows the biological-attack induced surface degradation resulting in debris and fatigue. Future design and selection of implant materials should consider such factors for improvement.

  5. Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants.

    Science.gov (United States)

    Zhou, Yan; Perkins, Luke A; Wang, Guodong; Zhou, Dongsheng; Liang, Hong

    2015-10-15

    Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with the evidence of increased surface roughness and embrittlement. Depredated surface of the Ti plate resulted debris particles in the surrounding tissue of 15.2 ± 6.5 μm in size. Nanoparticles were observed in transmission electron microscope. The electron diffraction pattern of the debris indicates a combination of nanocrystalline and amorphous phases. The failure mode of the broken nail made of stainless steel was found to be fatigue initiated from the surface. This study clearly shows the biological-attack induced surface degradation resulting in debris and fatigue. Future design and selection of implant materials should consider such factors for improvement.

  6. Bone density in relation to failure in patients with osteosynthesized femoral neck fractures

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Ryg, Jesper; Lauritsen, Jens

    2011-01-01

    Background The treatment of femoral neck fracture with internal fixation (IF) is recommended in younger patients and has compared to arthroplasty the advantage of retaining the femoral head. A big problem with osteosynthesis is though failure. Finding predictors for fixation failure is still......,2 (75,4-79,0). Failure is defined as revision surgery or new fracture. Results 69 patients had a t-score (total hip) below -2,5 SD as defined for osteoporosis. At 1 year the overall (dislocated) failure rate was 34,5 % (44,7 %), at 2 years 45,4 % (60,0 %) and at end of follow-up 49,6 % (62...

  7. Toward FRP-Based Brain-Machine Interfaces-Single-Trial Classification of Fixation-Related Potentials.

    Directory of Open Access Journals (Sweden)

    Andrea Finke

    Full Text Available The co-registration of eye tracking and electroencephalography provides a holistic measure of ongoing cognitive processes. Recently, fixation-related potentials have been introduced to quantify the neural activity in such bi-modal recordings. Fixation-related potentials are time-locked to fixation onsets, just like event-related potentials are locked to stimulus onsets. Compared to existing electroencephalography-based brain-machine interfaces that depend on visual stimuli, fixation-related potentials have the advantages that they can be used in free, unconstrained viewing conditions and can also be classified on a single-trial level. Thus, fixation-related potentials have the potential to allow for conceptually different brain-machine interfaces that directly interpret cortical activity related to the visual processing of specific objects. However, existing research has investigated fixation-related potentials only with very restricted and highly unnatural stimuli in simple search tasks while participant's body movements were restricted. We present a study where we relieved many of these restrictions while retaining some control by using a gaze-contingent visual search task. In our study, participants had to find a target object out of 12 complex and everyday objects presented on a screen while the electrical activity of the brain and eye movements were recorded simultaneously. Our results show that our proposed method for the classification of fixation-related potentials can clearly discriminate between fixations on relevant, non-relevant and background areas. Furthermore, we show that our classification approach generalizes not only to different test sets from the same participant, but also across participants. These results promise to open novel avenues for exploiting fixation-related potentials in electroencephalography-based brain-machine interfaces and thus providing a novel means for intuitive human-machine interaction.

  8. REVISION ANKLE SYNDESMOSIS FIXATION - FUNCTIONAL OUTCOME AFTER TIGHTROPE ® FIXATION

    Directory of Open Access Journals (Sweden)

    Sendhilvelan Rajagopalan

    2016-07-01

    Full Text Available BACKGROUND Syndesmotic disruptions are often seen in ankle fractures. Malreduction of these fractures can result in arthritis and instability. A proportion of these patients with malreduction require revision fixation. This study presents the results of revision fixation in such patients, using the Ankle TightRope ® (Arthrex system. METHODS Between January 2000 to December 2009, 124 patients who underwent ankle fracture fixations with syndesmotic stabilisation were analysed. Out of 124 patients, 8 patients were diagnosed with failure of primary stabilisation (based on radiological and clinical criteria and subjected to revision fixation using the Ankle TightRope ® (Arthrex system. Followup was done at periodic time intervals of 3, 6 and 12 months. Both clinical and radiological assessment was performed. Complications and duration of hospital stay was recorded. Functional evaluation was performed using the American Orthopaedic Foot and Ankle Society (AOFAS scoring system. RESULTS Five patients had good results, one satisfactory and two had poor outcomes. CONCLUSIONS Ankle TightRope ® fixation is an alternative method of stabilisation in patients who require revision syndesmosis fixation. Further studies are required to evaluate this method of revision stabilisation as compared to screws.

  9. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.

    Science.gov (United States)

    Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven

    2010-05-01

    This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.

  10. Fusion Surgery Required for Recurrent Pediatric Atlantoaxial Rotatory Fixation after Failure of Temporary Fixation with Instrumentation

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Matsuyama

    2017-01-01

    Full Text Available In cases of chronic irreducible and recurrent unstable atlantoaxial rotatory fixation (AARF, closed reduction and its maintenance are often unsuccessful, requiring surgical treatment. The purpose of the present report is to describe a rare case of pediatric AARF that required multiple treatments. A 6-year-old boy was diagnosed as having type 2 AARF. After conservative treatment, the patient was treated with temporary fixation surgery (C1-C2 Magerl without a bone graft in consideration of motion preservation after screw removal. AARF recurred after the screw removal and required fusion surgery (Magerl–Brooks with an iliac bone graft. Ultimately, bone union was achieved and the screws were removed 11 months after the surgery. We recommend surgeons be cautious when choosing temporary fixation surgery for AARF in small children. Further investigation is needed to determine the optimal time before screw removal.

  11. Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation.

    Science.gov (United States)

    Ma, C Benjamin; Comerford, Lyn; Wilson, Joseph; Puttlitz, Christian M

    2006-02-01

    Recent studies have shown that arthroscopic rotator cuff repairs can have higher rates of failure than do open repairs. Current methods of rotator cuff repair have been limited to single-row fixation of simple and horizontal stitches, which is very different from open repairs. The objective of this study was to compare the initial cyclic loading and load-to-failure properties of double-row fixation with those of three commonly used single-row techniques. Ten paired human supraspinatus tendons were split in half, yielding four tendons per cadaver. The bone mineral content at the greater tuberosity was assessed. Four stitch configurations (two-simple, massive cuff, arthroscopic Mason-Allen, and double-row fixation) were randomized and tested on each set of tendons. Specimens were cyclically loaded between 5 and 100 N at 0.25 Hz for fifty cycles and then loaded to failure under displacement control at 1 mm/sec. Conditioning elongation, peak-to-peak elongation, ultimate tensile load, and stiffness were measured with use of a three-dimensional tracking system and compared, and the failure type (suture or anchor pull-out) was recorded. No significant differences were found among the stitches with respect to conditioning elongation. The mean peak-to-peak elongation (and standard error of the mean) was significantly lower for the massive cuff (1.1 +/- 0.1 mm) and double-row stitches (1.1 +/- 0.1 mm) than for the arthroscopic Mason-Allen stitch (1.5 +/- 0.2 mm) (p row fixation (287 +/- 24 N) than for all of the single-row fixations (p row fixation had a significantly higher ultimate tensile load than the three types of single-row fixation stitches. Of the single-row fixations, the massive cuff stitch had cyclic and load-to-failure characteristics similar to the double-row fixation. Anterior repairs of the supraspinatus tendon had significantly stronger biomechanical behavior than posterior repairs.

  12. The effect of cement on hip stem fixation: a biomechanical study.

    Science.gov (United States)

    Çelik, Talip; Mutlu, İbrahim; Özkan, Arif; Kişioğlu, Yasin

    2017-06-01

    This study presents the numerical analysis of stem fixation in hip surgery using with/without cement methods since the use of cement is still controversial based on the clinical studies in the literature. Many different factors such as stress shielding, aseptic loosening, material properties of the stem, surgeon experiences etc. play an important role in the failure of the stem fixations. The stem fixation methods, cemented and uncemented, were evaluated in terms of mechanical failure aspects using computerized finite element method. For the modeling processes, three dimensional (3D) femur model was generated from computerized tomography (CT) images taken from a patient using the MIMICS Software. The design of the stem was also generated as 3D CAD model using the design parameters taken from the manufacturer catalogue. These 3D CAD models were generated and combined with/without cement considering the surgical procedure using SolidWorks program and then imported into ANSYS Workbench Software. Two different material properties, CoCrMo and Ti6Al4V, for the stem model and Poly Methyl Methacrylate (PMMA) for the cement were assigned. The material properties of the femur were described according to a density calculated from the CT images. Body weight and muscle forces were applied on the femur and the distal femur was fixed for the boundary conditions. The calculations of the stress distributions of the models including cement and relative movements of the contacts examined to evaluate the effects of the cement and different stem material usage on the failure of stem fixation. According to the results, the use of cement for the stem fixation reduces the stress shielding but increases the aseptic loosening depending on the cement crack formations. Additionally, using the stiffer material for the stem reduces the cement stress but increases the stress shielding. Based on the results obtained in the study, even when taking the disadvantages into account, the cement usage

  13. Fixation distance and fixation duration to vertical road signs.

    Science.gov (United States)

    Costa, Marco; Simone, Andrea; Vignali, Valeria; Lantieri, Claudio; Palena, Nicola

    2018-05-01

    The distance of first-fixation to vertical road signs was assessed in 22 participants while driving a route of 8.34 km. Fixations to road signs were recorded by a mobile eye-movement-tracking device synchronized to GPS and kinematic data. The route included 75 road signs. First-fixation distance and fixation duration distributions were positively skewed. Median distance of first-fixation was 51 m. Median fixation duration was 137 ms with a modal value of 66 ms. First-fixation distance was linearly related to speed and fixation duration. Road signs were gazed at a much closer distance than their visibility distance. In a second study a staircase procedure was used to test the presentation-time threshold that lead to a 75% accuracy in road sign identification. The threshold was 35 ms, showing that short fixations to a road signs could lead to a correct identification. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Biomechanical Evaluation of Standard Versus Extended Proximal Fixation Olecranon Plates for Fixation of Olecranon Fractures.

    Science.gov (United States)

    Boden, Allison L; Daly, Charles A; Dalwadi, Poonam P; Boden, Stephanie A; Hutton, William C; Muppavarapu, Raghuveer C; Gottschalk, Michael B

    2018-01-01

    Small olecranon fractures present a significant challenge for fixation, which has resulted in development of plates with proximal extension. Olecranon-specific plates with proximal extensions are widely thought to offer superior fixation of small proximal fragments but have distinct disadvantages: larger dissection, increased hardware prominence, and the increased possibility of impingement. Previous biomechanical studies of olecranon fracture fixation have compared methods of fracture fixation, but to date there have been no studies defining olecranon plate fixation strength for standard versus extended olecranon plates. The purpose of this study is to evaluate the biomechanical utility of the extended plate for treatment of olecranon fractures. Sixteen matched pairs of fresh-frozen human cadaveric elbows were used. Of the 16, 8 matched pairs received a transverse osteotomy including 25% and 8 including 50% of the articular surface on the proximal fragment. One elbow from each pair was randomly assigned to a standard-length plate, and the other elbow in the pair received the extended-length plate, for fixation of the fracture. The ulnae were cyclically loaded and subsequently loaded to failure, with ultimate load, number of cycles, and gap formation recorded. There was no statistically significant difference between the standard and extended fixation plates in simple transverse fractures at either 25% or 50% from the proximal most portion of the articular surface of the olecranon. Standard fixation plates are sufficient for the fixation of small transverse fractures, but caution should be utilized particularly with comminution and nontransverse fracture patterns.

  15. Biomechanical Strength of Retrograde Fixation in Proximal Third Scaphoid Fractures.

    Science.gov (United States)

    Daly, Charles A; Boden, Allison L; Hutton, William C; Gottschalk, Michael B

    2018-04-01

    Current techniques for fixation of proximal pole scaphoid fractures utilize antegrade fixation via a dorsal approach endangering the delicate vascular supply of the dorsal scaphoid. Volar and dorsal approaches demonstrate equivalent clinical outcomes in scaphoid wrist fractures, but no study has evaluated the biomechanical strength for fractures of the proximal pole. This study compares biomechanical strength of antegrade and retrograde fixation for fractures of the proximal pole of the scaphoid. A simulated proximal pole scaphoid fracture was produced in 22 matched cadaveric scaphoids, which were then assigned randomly to either antegrade or retrograde fixation with a cannulated headless compression screw. Cyclic loading and load to failure testing were performed and screw length, number of cycles, and maximum load sustained were recorded. There were no significant differences in average screw length (25.5 mm vs 25.6 mm, P = .934), average number of cyclic loading cycles (3738 vs 3847, P = .552), average load to failure (348 N vs 371 N, P = .357), and number of catastrophic failures observed between the antegrade and retrograde fixation groups (3 in each). Practical equivalence between the 2 groups was calculated and the 2 groups were demonstrated to be practically equivalent (upper threshold P = .010). For this model of proximal pole scaphoid wrist fractures, antegrade and retrograde screw configuration have been proven to be equivalent in terms of biomechanical strength. With further clinical study, we hope surgeons will be able to make their decision for fixation technique based on approaches to bone grafting, concern for tenuous blood supply, and surgeon preference without fear of poor biomechanical properties.

  16. Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.

    Science.gov (United States)

    Wegner, Adam M; Wolinsky, Philip R; Robbins, Michael A; Garcia, Tanya C; Amanatullah, Derek F

    2018-05-01

    Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. Specimens were subjected to offset axial tension loading on a servohydraulic testing system and tracked using high-resolution video. Failure was defined as 2 mm of articular displacement. Analysis of variance followed by a Tukey-Kramer post hoc test was used to assess for differences between groups, with significance defined as Pfragment T-plate constructs (239±83 N/mm and 190±37 N/mm) and the bicortical screw construct (240±17 N/mm) were not statistically different. The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.]. Copyright 2018, SLACK Incorporated.

  17. Decision-making in information seeking on texts: an eye-fixation-related potentials investigation.

    Science.gov (United States)

    Frey, Aline; Ionescu, Gelu; Lemaire, Benoit; López-Orozco, Francisco; Baccino, Thierry; Guérin-Dugué, Anne

    2013-01-01

    Reading on a web page is known to be not linear and people need to make fast decisions about whether they have to stop or not reading. In such context, reading, and decision-making processes are intertwined and this experiment attempts to separate them through electrophysiological patterns provided by the Eye-Fixation-Related Potentials technique (EFRPs). We conducted an experiment in which EFRPs were recorded while participants read blocks of text that were semantically highly related, moderately related, and unrelated to a given goal. Participants had to decide as fast as possible whether the text was related or not to the semantic goal given at a prior stage. Decision making (stopping information search) may occur when the paragraph is highly related to the goal (positive decision) or when it is unrelated to the goal (negative decision). EFRPs were analyzed on and around typical eye fixations: either on words belonging to the goal (target), subjected to a high rate of positive decisions, or on low frequency unrelated words (incongruent), subjected to a high rate of negative decisions. In both cases, we found EFRPs specific patterns (amplitude peaking between 51 to 120 ms after fixation onset) spreading out on the next words following the goal word and the second fixation after an incongruent word, in parietal and occipital areas. We interpreted these results as delayed late components (P3b and N400), reflecting the decision to stop information searching. Indeed, we show a clear spill-over effect showing that the effect on word N spread out on word N + 1 and N + 2.

  18. Decision-making in information seeking on texts: an eye-fixation-related potentials investigation

    Science.gov (United States)

    Frey, Aline; Ionescu, Gelu; Lemaire, Benoit; López-Orozco, Francisco; Baccino, Thierry; Guérin-Dugué, Anne

    2013-01-01

    Reading on a web page is known to be not linear and people need to make fast decisions about whether they have to stop or not reading. In such context, reading, and decision-making processes are intertwined and this experiment attempts to separate them through electrophysiological patterns provided by the Eye-Fixation-Related Potentials technique (EFRPs). We conducted an experiment in which EFRPs were recorded while participants read blocks of text that were semantically highly related, moderately related, and unrelated to a given goal. Participants had to decide as fast as possible whether the text was related or not to the semantic goal given at a prior stage. Decision making (stopping information search) may occur when the paragraph is highly related to the goal (positive decision) or when it is unrelated to the goal (negative decision). EFRPs were analyzed on and around typical eye fixations: either on words belonging to the goal (target), subjected to a high rate of positive decisions, or on low frequency unrelated words (incongruent), subjected to a high rate of negative decisions. In both cases, we found EFRPs specific patterns (amplitude peaking between 51 to 120 ms after fixation onset) spreading out on the next words following the goal word and the second fixation after an incongruent word, in parietal and occipital areas. We interpreted these results as delayed late components (P3b and N400), reflecting the decision to stop information searching. Indeed, we show a clear spill-over effect showing that the effect on word N spread out on word N + 1 and N + 2. PMID:23966913

  19. Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients

    Directory of Open Access Journals (Sweden)

    Bhava RJ Satish

    2013-01-01

    Conclusion: Closed reduction and cannulated cancellous screw fixation gives satisfactory functional results in large group of elderly patients. The four quadrant parallel peripheral (FQPP screw fixation technique gives good stability, allows controlled collapse, avoids fixation failure and achieves predictable bone healing in displaced femoral neck fracture in patients ≥50 years of age.

  20. Failure of fixation of trochanteric femur fractures: Clinical recommendations for avoiding Z-effect and reverse Z-effect type complications

    Directory of Open Access Journals (Sweden)

    Balbachevsky Daniel

    2011-06-01

    Full Text Available Abstract Background Z-effect and reverse Z-effect are complications that arise from the surgical treatment of pertrochanteric fractures of the femur with proximal femoral nails (PFN comprising two interlocking head screws. Such complications are induced by the migration of screws in opposite directions, which may lead to failure of the osteosynthesis. Findings The paper describes three cases of pertrochanteric fractures that were treated with PFN with two interlocking screws that evolved to either Z-effect or reverse Z-effect. Literature-based explanations for this phenomenon are provided together with recommendations of how to avoid such complications. Conclusions Although intramedullary fixation is an established method of treatment of femoral intertrochanteric and subtrochanteric fractures, the evolution of the procedure may include complications associated with the migration of the interlocking head screws. The occurrence of Z-effect and reverse Z-effect has not been completely elucidated, but the main causes of such complications are probably fracture fixation in varus position, severe medial comminution, inappropriate entry point of the nail and poor bone quality.

  1. Water Conservation in Kalanchoe blossfeldiana in Relation to Carbon Dioxide Dark Fixation

    Science.gov (United States)

    Zabka, George G.; Chaturvedi, S. N.

    1975-01-01

    The succulent Kalanchoe blossfeldiana v. Poel. var Tom Thumb was treated on long and short photoperiods for 6 weeks during which short day plants developed thicker leaves, flowered prolifically, and exhibited extensive net dark fixation of carbon dioxide. In contrast, long day plants remained vegetative and did not develop thicker leaves or exhibit net carbon dioxide dark fixation. When examined after the photoperiodic state described, long day plants showed approximately three times more water loss over a 10-day period than short day plants. Water loss is similar during light and dark periods for short day plants but long day plants exhibited two times more water loss during the day than at night. The latter plants also lost three and one-half times more water during the light period than short day plants. The water conservation by short day plants is correlated with conditions of high carbon dioxide dark fixation and effects of its related Crassulacean acid metabolism on stomatal behavior. PMID:16659116

  2. Water Conservation in Kalanchoe blossfeldiana in Relation to Carbon Dioxide Dark Fixation.

    Science.gov (United States)

    Zabka, G G; Chaturvedi, S N

    1975-03-01

    The succulent Kalanchoe blossfeldiana v. Poel. var Tom Thumb was treated on long and short photoperiods for 6 weeks during which short day plants developed thicker leaves, flowered prolifically, and exhibited extensive net dark fixation of carbon dioxide. In contrast, long day plants remained vegetative and did not develop thicker leaves or exhibit net carbon dioxide dark fixation. When examined after the photoperiodic state described, long day plants showed approximately three times more water loss over a 10-day period than short day plants. Water loss is similar during light and dark periods for short day plants but long day plants exhibited two times more water loss during the day than at night. The latter plants also lost three and one-half times more water during the light period than short day plants. The water conservation by short day plants is correlated with conditions of high carbon dioxide dark fixation and effects of its related Crassulacean acid metabolism on stomatal behavior.

  3. Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty.

    Science.gov (United States)

    de Ruiter, Lennert; Janssen, Dennis; Briscoe, Adam; Verdonschot, Nico

    2017-11-01

    Introducing polyetheretherketone (PEEK) polymer as a material for femoral components in total knee arthroplasty (TKA) could potentially lead to a reduction of the cemented fixation strength. A PEEK implant is more likely to deform under high loads, rendering geometrical locking features less effective. Fixation strength may be enhanced by adding more undercuts or specific surface treatments. The aim of this study is to measure the initial fixation strength and investigate the associated failure patterns of three different iterations of PEEK-OPTIMA ® implants compared with a Cobalt-Chromium (CoCr) component. Femoral components were cemented onto trabecular bone analogue foam blocks and preconditioned with 86,400 cycles of compressive loading (2600 N-260 N at 1 Hz). They were then extracted while the force was measured and the initial failure mechanism was recorded. Four groups were compared: CoCr, regular PEEK, PEEK with an enhanced cement-bonding surface and the latter with additional surface primer. The mean pull-off forces for the four groups were 3814 N, 688 N, 2525 N and 2552 N, respectively. The initial failure patterns for groups 1, 3 and 4 were the same; posterior condylar foam fracture and cement-bone debonding. Implants from group 2 failed at the cement-implant interface. This study has shown that a PEEK-OPTIMA ® femoral TKA component with enhanced macro- and microtexture is able to replicate the main failure mechanism of a conventional CoCr femoral implant. The fixation strength is lower than for a CoCr implant, but substantially higher than loads occurring under in-vivo conditions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Short Segment Fixation Versus Short Segment Fixation With Pedicle Screws at the Fracture Level for Thoracolumbar Burst Fracture

    Directory of Open Access Journals (Sweden)

    Anghel S

    2014-04-01

    Full Text Available Objective: The most prevailing surgical procedure in the treatment of thoracolumbar burst fractures, Short Segment Fixation (SSF, is often followed by loss of correction or hardware failure which may be significant enough to require another surgical intervention. In order to take advantage of its benefits but to avoid or diminish the risk and impact of associated drawbacks, some other alternatives have been lately developed among which we refer to short segment fixation with intermediate screws (SSF+IS. This article provides a comparative picture over the effectiveness of the two above-mentioned surgical treatments, focusing on their potential to prevent the loss of correction.

  5. Biomechanical Comparison of External Fixation and Compression Screws for Transverse Tarsal Joint Arthrodesis.

    Science.gov (United States)

    Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E

    2015-10-01

    Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that

  6. Nitrogen fixation, denitrification, and ecosystem nitrogen pools in relation to vegetation development in the Subarctic

    DEFF Research Database (Denmark)

    Sørensen, Pernille Lærkedal; Jonasson, Sven Evert; Michelsen, Anders

    2006-01-01

    Nitrogen (N) fixation, denitrification, and ecosystem pools of nitrogen were measured in three subarctic ecosystem types differing in soil frost-heaving activity and vegetation cover. N2-fixation was measured by the acetylene reduction assay and converted to absolute N ecosystem input by estimates...... of conversion factors between acetylene reduction and 15N incorporation. One aim was to relate nitrogen fluxes and nitrogen pools to the mosaic of ecosystem types of different stability common in areas of soil frost movements. A second aim was to identify abiotic controls on N2-fixation by simultaneous...... measurements of temperature, light, and soil moisture. Nitrogen fixation rate was high with seasonal input estimated at 1.1 g N m2 on frostheaved sorted circles, which was higher than the total plant N content and exceeded estimated annual plant N uptake several-fold but was lower than the microbial N content...

  7. Accidental perforation of the lateral femoral cortex in ACL reconstruction: an investigation of mechanical properties of different fixation techniques.

    Science.gov (United States)

    Herbort, Mirco; Heletta, Sebastian; Raschke, Michael J; Schliemann, Benedikt; Osada, Nani; Petersen, Wolf; Zantop, Thore

    2012-03-01

    The aim of this study was to evaluate the mechanical properties of anterior cruciate ligament (ACL) reconstruction using the medial portal technique with cortical fixation and hybrid fixation after penetration of the lateral cortex by use of different drill sizes. In this biomechanical study a porcine in vitro model was used. The testing protocol consisted of a cyclic loading protocol (1,000 cycles, 50 and 250 N) and subsequent ultimate failure testing. Number of cyclic loadings survived, stiffness, yield load, maximum load, and graft elongation, as well as failure mode, were analyzed after ACL reconstruction with 5- to 9-mm soft-tissue grafts. In the control group, conventional penetration of the lateral cortex with a 4.5-mm drill and cortical fixation were performed. In the tested groups, the lateral cortex was penetrated with a drill matching the graft size. In the first part of the study, we used cortical fixation. In the second part, we used hybrid fixation with an interference screw. In the first part of the study, ACL reconstruction with 5- to 6-mm perforation of the lateral cortex showed no significant differences in ultimate failure load after cyclic loading compared with the control group (P > .05). Specimens with reconstruction with 7- to 9-mm perforation of the lateral cortex and cortical fixation did not survive the cyclic loading protocol. In the second part of the study, with a hybrid fixation technique, ultimate failure testing after cyclic loading of specimens with 7- to 9-mm penetration showed no significant differences in tested parameters compared with the control group (P > .05). After penetration of the lateral cortex with a drill size of more than 6 mm, cortical ACL fixation results in poor mechanical properties. Hybrid fixation increases the mechanical properties significantly after penetration with a 7- to 9-mm drill. We advise caution to avoid penetration of the lateral femoral cortex when using cortical flip-button fixation. In case of

  8. Guide to radiation fixatives

    International Nuclear Information System (INIS)

    Tawil, J.J.; Bold, F.C.

    1983-11-01

    This report identifies and then characterizes a variety of substances available in the market place for potential effectiveness as a fixative on radiologically contaminated surfaces. The substances include both generic chemicals and proprietary products. In selecting a fixative for a particular application, several attributes of the fixative may be relevant to the choice. These attributes include: toxicity, durability, and cleanliness and removability. In addition to the attributes of the fixative, one should also take into account certain characteristics of the site to be treated. These characteristics relate to climate, nature of the surface, use to which the treated surface will be put, subsequent cleanup operations, and type of neighboring surfaces. Finally, costs and potential environmental effects may influence the decision. A variety of fixatives are evaluated with respect to these various attributes and summarized in a reference table

  9. Experimental Fracture Model versus Osteotomy Model in Metacarpal Bone Plate Fixation

    Directory of Open Access Journals (Sweden)

    S. Ochman

    2011-01-01

    Full Text Available Introduction. Osteotomy or fracture models can be used to evaluate mechanical properties of fixation techniques of the hand skeleton in vitro. Although many studies make use of osteotomy models, fracture models simulate the clinical situation more realistically. This study investigates monocortical and bicortical plate fixation on metacarpal bones considering both aforementioned models to decide which method is best suited to test fixation techniques. Methods. Porcine metacarpal bones (=40 were randomized into 4 groups. In groups I and II bones were fractured with a modified 3-point bending test. The intact bones represented a further control group to which the other groups after fixation were compared. In groups III and IV a standard osteotomy was carried out. Bones were fixated with plates monocortically (group I, III and bicortically (group II, IV and tested for failure. Results. Bones fractured at a mean maximum load of 482.8 N ± 104.8 N with a relative standard deviation (RSD of 21.7%, mean stiffness was 122.3 ± 35 N/mm. In the fracture model, there was a significant difference (=0.01 for maximum load of monocortically and bicortically fixed bones in contrast to the osteotomy model (=0.9. Discussion. In the fracture model, because one can use the same bone for both measurements in the intact state and the bone-plate construct states, the impact of inter-individual differences is reduced. In contrast to the osteotomy model there are differences between monocortical and bicortical fixations in the fracture model. Thus simulation of the in vivo situation is better and seems to be suitable for the evaluation of mechanical properties of fixation techniques on metacarpals.

  10. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Seifert, Robert; Theisen, Christina; Gehweiler, Dominic; Wähnert, Dirk; Schulze, Martin; Raschke, Michael J; Weimann, Andre

    2017-01-01

    The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.

  11. [Comparison of external fixation with or without limited internal fixation for open knee fractures].

    Science.gov (United States)

    Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S

    2018-03-01

    Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60

  12. Modeling fixation locations using spatial point processes.

    Science.gov (United States)

    Barthelmé, Simon; Trukenbrod, Hans; Engbert, Ralf; Wichmann, Felix

    2013-10-01

    Whenever eye movements are measured, a central part of the analysis has to do with where subjects fixate and why they fixated where they fixated. To a first approximation, a set of fixations can be viewed as a set of points in space; this implies that fixations are spatial data and that the analysis of fixation locations can be beneficially thought of as a spatial statistics problem. We argue that thinking of fixation locations as arising from point processes is a very fruitful framework for eye-movement data, helping turn qualitative questions into quantitative ones. We provide a tutorial introduction to some of the main ideas of the field of spatial statistics, focusing especially on spatial Poisson processes. We show how point processes help relate image properties to fixation locations. In particular we show how point processes naturally express the idea that image features' predictability for fixations may vary from one image to another. We review other methods of analysis used in the literature, show how they relate to point process theory, and argue that thinking in terms of point processes substantially extends the range of analyses that can be performed and clarify their interpretation.

  13. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots.

    Science.gov (United States)

    Busfield, Benjamin T; Glousman, Ronald E; McGarry, Michelle H; Tibone, James E; Lee, Thay Q

    2008-05-01

    Previous studies have shown comparable biomechanical properties of double-row fixation versus double-row fixation with a knotless lateral row. SutureBridge is a construct that secures the cuff with medial row mattress suture anchors and knotless lateral row fixation of the medial suture ends. Recent completely knotless constructs may lead to lesser clinical outcomes if the construct properties are compromised from lack of suture knots. A completely knotless construct without medial row knots will compromise the biomechanical properties in both cyclic and failure-testing parameters. Controlled laboratory study. Six matched pairs of cadaveric shoulders were randomized to 2 groups of double row fixation with SutureBridge: group 1 with medial row knots, and group 2 without medial row knots. The specimens were placed in a materials test system at 30 degrees of abduction. Cyclic testing to 180 N at 1 mm/sec for 30 cycles was performed, followed by tensile testing to failure at 1 mm/sec. Data included cyclic and failure data from the materials test system and gap data using a video digitizing system. All data from paired specimens were compared using paired Student t tests. Group 1 had a statistically significant difference (P row failure, whereas all group 1 specimens failed at the clamp. Although lateral row knotless fixation has been shown not to sacrifice structural integrity of this construct, the addition of a knotless medial row compromises the construct leading to greater gapping and failure at lower loads. This may raise concerns regarding recently marketed completely knotless double row constructs.

  14. Surgical strategies to improve fixation in the osteoporotic spine: the effects of tapping, cement augmentation, and screw trajectory.

    Science.gov (United States)

    Kuhns, Craig A; Reiter, Michael; Pfeiffer, Ferris; Choma, Theodore J

    2014-02-01

    Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw insertion. Then we evaluated load to failure of screws placed in bone block models with a straight-ahead screw trajectory as well as with screws having a 23-degree cephalad trajectory (toward the end plate). These techniques were tested with nonaugmented (NA) screws as well as with bioactive cement (BioC) augmentation prior to screw insertion. Results In the NA group, pretapping decreased fixation strength in a dose-dependent fashion. In the BioC group, the tapped screws had significantly greater loads to failure (p tapping prior to cement augmentation will substantially improve fixation when compared with not tapping. Angulating screws more cephalad also seems to enhance aging spine fixation.

  15. Assessment of Attentional Workload while Driving by Eye-fixation-related Potentials

    Science.gov (United States)

    Takeda, Yuji; Yoshitsugu, Noritoshi; Itoh, Kazuya; Kanamori, Nobuhiro

    How do drivers cope with the attentional workload of in-vehicle information technology? In the present study, we propose a new psychophysiological measure for assessing drivers' attention: eye-fixation-related potential (EFRP). EFRP is a kind of event-related brain potential measurable at the eye-movement situation that reflects how closely observers examine visual information at the eye-fixated position. In the experiment, the effects of verbal working memory load and spatial working memory load during simulated driving were examined by measuring the number of saccadic eye-movements and EFRP as the indices of drivers' attention. The results showed that the spatial working memory load affected both the number of saccadic eye-movements and the amplitude of the P100 component of EFRP, whereas the verbal working memory load affected only the number of saccadic eye-movements. This implies that drivers can perform time-sharing processing between driving and the verbal working memory task, but the decline of accuracy of visual processing during driving is inescapable when the spatial working memory load is given. The present study suggests that EFRP can provide a new index of drivers' attention, other than saccadic eye-movements.

  16. Strength of titanium intramedullary implant versus miniplate fixation of mandibular condyle fractures.

    Science.gov (United States)

    Frake, Paul C; Howell, Rebecca J; Joshi, Arjun S

    2012-07-01

    To test the strength of internal fixation of mandibular condyle fractures repaired with titanium miniplates versus titanium intramedullary implants. Prospective laboratory experimentation in urethane mandible models and human cadaveric mandibles. Materials testing laboratory at an academic medical center. Osteotomies of the mandibular condyle were created in 40 urethane hemimandible models and 24 human cadaveric specimens. Half of the samples in each group were repaired with traditional miniplates, and the other half were repaired with intramedullary titanium implants. Anteroposterior and mediolateral loads were applied to the samples, and the displacement was measured with reference to the applied force. Titanium intramedullary implants demonstrated statistically significant improved strength and stiffness versus miniplates in the urethane model experimental groups. Despite frequent plastic deformation and mechanical failures of the miniplates, a 1.6-mm-diameter titanium intramedullary pin did not mechanically fail in any of the cases. Intramedullary implantation failures were due to secondary fracture of the adjacent cortical bone or experimental design limitations including rotation of the smooth pin implant. Mechanical implant failures that were encountered with miniplate fixation were not seen with titanium intramedullary implants. These intramedullary implants provide stronger and more rigid fixation of mandibular condyle fractures than miniplates in this in vitro model.

  17. Fixation stability and implication for multifocal electroretinography in patients with neovascular age-related macular degeneration after anti-VEGF treatment

    DEFF Research Database (Denmark)

    Pedersen, Karen Bjerg; Sjølie, Anne Katrin; Vestergaard, Anders Højslet

    2016-01-01

    Purpose: To quantify fixation stability in patients with neovascular age-related macular degeneration (nAMD) at baseline, 3 and 6 months after anti-vascular endothelial growth factor (anti-VEGF) treatment and furthermore asses the implications of an unsteady fixation for multifocal...

  18. Could persistency of current of injury forecast successful active-fixation pacing lead implantation?

    Science.gov (United States)

    Shali, Shalaimaiti; Su, Yangang; Qin, Shengmei; Ge, Junbo

    2018-05-01

    Presence of adequate current of injury (COI) was recognized as a sign of favorable pacemaker lead outcome. Little is known regarding the value of its dynamic behavior. We sought to test whether persistency of COI could predict active-fixation pacing lead performance. COI was monitored up to 10min after right ventricular (RV) pacing electrode fixation. COI persistency was defined as the percentage of COI magnitude relative to its initial measurement. An unacceptable pacing threshold (≥1.0V in acute evaluation or ≥2.0V over 2-year follow-up) with or without lead dislodgement was considered as lead failure. Lead implantation was attempted for 217 times in 174 patients (age 66.3±7.8years, 78 female). Acute lead failures occurred 43 times. Independent predictors of acute lead failure were RV enlargement (odds ratio [OR] 1.23, 95% confidential interval [CI] 1.11-2.04, P=0.033), absence of COI (OR 3.13, 95%CI 2.08-9.09, P=0.027), and COI persistency at 5min (OR 0.32, 95%CI 0.20-0.69, P=0.001) and 10min (OR 0.41, 95%CI 0.13-0.77, P=0.001). The optimal cutoffs were COI 5min persistency ≥50% (sensitivity 81.4%; specificity 81.9%) and COI 10min persistency ≥20% (sensitivity 86%; specificity 88.6%). There were 12 lead failures during 24.0±6.4months of follow-up. Patients with COI 5min persistency ≥50% had higher event-free survival compared to those with COI 5min persistency <50% (hazard ratio 3.54, 95% CI 1.04-12.06, P=0.043). COI persistency appears to be a valuable indicator for both acute and long-term outcome of active-fixation pacemaker leads. A precipitous decline in COI may require more attention to make sure of the lead performance. Copyright © 2018 Elsevier Ireland Ltd. All rights reserved.

  19. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

    Science.gov (United States)

    Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal

    2014-01-01

    Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Risk factors of avascular necrosis of the femoral head and fixation failure in patients with valgus angulated femoral neck fractures over the age of 50 years.

    Science.gov (United States)

    Song, Hyung Keun; Choi, Ho June; Yang, Kyu Hyun

    2016-12-01

    The aim of our study was to identify the risk factors for avascular necrosis of the femoral head (AVN) and fixation failure (FF) after screw osteosynthesis in patients with valgus angulated femoral neck fractures. We conducted a retrospective study of 308 patients (mean age, 72.5 years, range, 50-97 years), with a mean follow-up of 21.4 months (range, 12-64 months). The risk for failure in treatment (FIT) associated with patient- and fracture-related factors was evaluated by logistic regression analyses. FIT was identified in 32 cases (10.3%): 22 cases (7.1%) of AVN and 10 cases (3.2%) of FF. Initial valgus tilt>15° (p=0.023), posterior tilt>15° (p=0.012), and screw sliding distance (p=0.037) were significantly associated with FIT. FIT occurred in 7 patients (5.2%) with B1.2.1 fractures and 17 patients (48.6%) with B1.1.2 fractures (p15° (B1.1.2) compared to patients with 15° are reasonable candidates for primary arthroplasty due to high risk of FIT. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Visual encoding and fixation target selection in free viewing: presaccadic brain potentials

    Directory of Open Access Journals (Sweden)

    Andrey R Nikolaev

    2013-06-01

    Full Text Available In scrutinizing a scene, the eyes alternate between fixations and saccades. During a fixation, two component processes can be distinguished: visual encoding and selection of the next fixation target. We aimed to distinguish the neural correlates of these processes in the electrical brain activity prior to a saccade onset. Participants viewed color photographs of natural scenes, in preparation for a change detection task. Then, for each participant and each scene we computed an image heat map, with temperature representing the duration and density of fixations. The temperature difference between the start and end points of saccades was taken as a measure of the expected task-relevance of the information concentrated in specific regions of a scene. Visual encoding was evaluated according to whether subsequent change was correctly detected. Saccades with larger temperature difference were more likely to be followed by correct detection than ones with smaller temperature differences. The amplitude of presaccadic activity over anterior brain areas was larger for correct detection than for detection failure. This difference was observed for short scrutinizing but not for long explorative saccades, suggesting that presaccadic activity reflects top-down saccade guidance. Thus, successful encoding requires local scanning of scene regions which are expected to be task-relevant. Next, we evaluated fixation target selection. Saccades moving up in temperature were preceded by presaccadic activity of higher amplitude than those moving down. This finding suggests that presaccadic activity reflects attention deployed to the following fixation location. Our findings illustrate how presaccadic activity can elucidate concurrent brain processes related to the immediate goal of planning the next saccade and the larger-scale goal of constructing a robust representation of the visual scene.

  2. Adjacent-segment disease after thoracic pedicle screw fixation.

    Science.gov (United States)

    Agarwal, Nitin; Heary, Robert F; Agarwal, Prateek

    2018-03-01

    OBJECTIVE Pedicle screw fixation is a technique widely used to treat conditions ranging from spine deformity to fracture stabilization. Pedicle screws have been used traditionally in the lumbar spine; however, they are now being used with increasing frequency in the thoracic spine as a more favorable alternative to hooks, wires, or cables. Although safety concerns, such as the incidence of adjacent-segment disease (ASD) after cervical and lumbar fusions, have been reported, such issues in the thoracic spine have yet to be addressed thoroughly. Here, the authors review the literature on ASD after thoracic pedicle screw fixation and report their own experience specifically involving the use of pedicle screws in the thoracic spine. METHODS Select references from online databases, such as PubMed (provided by the US National Library of Medicine at the National Institutes of Health), were used to survey the literature concerning ASD after thoracic pedicle screw fixation. To include the authors' experience at Rutgers New Jersey Medical School, a retrospective review of a prospectively maintained database was performed to determine the incidence of complications over a 13-year period in 123 consecutive adult patients who underwent thoracic pedicle screw fixation. Children, pregnant or lactating women, and prisoners were excluded from the review. By comparing preoperative and postoperative radiographic images, the occurrence of thoracic ASD and disease within the surgical construct was determined. RESULTS Definitive radiographic fusion was detected in 115 (93.5%) patients. Seven incidences of instrumentation failure and 8 lucencies surrounding the screws were observed. One patient was observed to have ASD of the thoracic spine. The mean follow-up duration was 50 months. CONCLUSIONS This long-term radiographic evaluation revealed the use of pedicle screws for thoracic fixation to be an effective stabilization modality. In particular, ASD seems to be less of a problem in the

  3. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  4. Sutureless Intrascleral Fixated Intraocular Lens Implantation.

    Science.gov (United States)

    Karadag, Remzi; Celik, Haci Ugur; Bayramlar, Huseyin; Rapuano, Christopher J

    2016-08-01

    To review sutureless intrascleral intraocular lens (IOL) fixation methods. Review of published literature. Sutureless intrascleral IOL fixation methods are newer and have been developed to eliminate the suture-related complications of sutured scleral fixation methods such as suture-induced inflammation or infection and IOL dislocation or subluxation due to suture degradation or suture breakage. Sutureless intrascleral fixation methods aim for intrascleral haptic fixation to achieve stability of the IOL. Various methods of sutureless scleral fixation have been described. Using a needle, a blade, or a trochar, sclerostomies are created in all techniques for intraocular access. Some surgeons prefer to create scleral tunnels, whereas others use scleral flaps for scleral fixation of haptics. The stability of IOLs is attained by the scar tissue formed around the haptics. Short-term results of these new methods are acceptable; studies including more cases with longer follow-up are needed to determine their long-term success. [J Cataract Refract Surg. 2016;32(9):586-597.]. Copyright 2016, SLACK Incorporated.

  5. Emotional event-related potentials are reduced if negative pictures presented at fixation are unattended.

    Science.gov (United States)

    Wiens, Stefan; Sand, Anders; Norberg, Joakim; Andersson, Per

    2011-05-20

    Viewing of emotional pictures elicits two event-related potentials (ERPs) to emotional versus neutral pictures: an early posterior negativity (EPN) and a late positive potential (LPP). Because it is unresolved whether these indexes of emotional processing are reduced to task-irrelevant pictures at fixation, negative and neutral pictures from the International Affective Picture Set (IAPS) were shown at fixation together with 6 letters that surrounded the pictures. In separate tasks, participants were instructed to attend either the pictures or the letters. When the pictures were task relevant, results showed an EPN and LPP. In contrast, when the pictures were task irrelevant, the EPN was eliminated and the LPP reduced. Performance was high in both tasks (hit rates>87%), but somewhat better when the pictures were relevant. However, analyses showed no relationship between this performance difference and the differences in EPN and LPP between tasks. These results suggest that emotional processing of strong, negative pictures is sensitive to manipulations of attention even if the pictures are shown at fixation. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Corrosion failure analysis as related to prevention of corrosion failures

    International Nuclear Information System (INIS)

    Suss, H.

    1977-10-01

    The factors and conditions which have contributed to many of the corrosion related service failures are discussed based on a review of actual case histories. The anti-corrosion devices which developed as a result of these failure analyses are reviewed, and the method which must be adopted and used to take advantage of the available corrosion prevention techniques is discussed

  7. Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support.

    Science.gov (United States)

    Perez-Orribo, Luis; Kalb, Samuel; Reyes, Phillip M; Chang, Steve W; Crawford, Neil R

    2013-04-15

    Seven different combinations of posterior screw fixation, with or without interbody support, were compared in vitro using nondestructive flexibility tests. To study the biomechanical behavior of a new cortical screw (CS) fixation construct relative to the traditional pedicle screw (PS) construct. The CS is an alternative to the PS for posterior fixation of the lumbar spine. The CS trajectory is more sagittally and cranially oriented than the PS, being anchored in the pars interarticularis. Like PS fixation, CS fixation uses interconnecting rods fastened with top-locking connectors. Stability after bilateral CS fixation was compared with stability after bilateral PS fixation in the setting of intact disc and with direct lateral interbody fixation (DLIF) or transforaminal lateral interbody fixation (TLIF) support. Standard nondestructive flexibility tests were performed in cadaveric lumbar specimens, allowing non-paired comparisons of specific conditions from 28 specimens (4 groups of 7) within a larger experiment of multiple hardware configurations. Condition tested and group from which results originated were as follows: (1) intact (all groups); (2) with L3-L4 bilateral PS-rods (group 1); (3) with bilateral CS-rods (group 2); (4) with DLIF (group 3); (5) with DLIF + CS-rods (group 4); (6) with DLIF + PS-rods (group 3); (7) with TLIF + CS-rods (group 2), and (8) with TLIF + PS-rods (group 2). To assess spinal stability, the mean range of motion, lax zone, and stiff zone at L3-L4 were compared during flexion-extension, lateral bending, and axial rotation. With intact disc, stability was equivalent after PS-rod and CS-rod fixation, except that PS-rod fixation was stiffer during axial rotation. With DLIF support, there was no significant difference in stability between PS-rod and CS-rod fixation. With TLIF support, PS-rod fixation was stiffer than CS-rod fixation during lateral bending. Bilateral CS-rod fixation provided about the same stability in cadaveric specimens

  8. Fixation methods in mandibular reconstruction using fibula grafts: a comparative study into the relative strength of three different types of osteosynthesis

    NARCIS (Netherlands)

    Strackee, S. D.; Kroon, F. H.; Bos, K. E.

    2001-01-01

    Bone staples made of a nickel titanium alloy exert dynamic compression, require little dissection, and may provide an alternative to conventional fixation in mandibular reconstruction with a free vascularized fibula graft. To evaluate its stability relative to conventional methods of fixation with

  9. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study.

    Science.gov (United States)

    Dickens, Aaron J; Salas, Christina; Rise, LeRoy; Murray-Krezan, Cristina; Taha, Mahmoud Reda; DeCoster, Thomas A; Gehlert, Rick J

    2015-01-01

    We performed a simple biomechanical study to compare the fixation strength of titanium mesh with traditional tension-band augmentation, which is a standard treatment for transverse patella fractures. We hypothesised that titanium mesh augmentation is not inferior in fixation strength to the standard treatment. Twenty-four synthetic patellae were tested. Twelve were fixed with stainless steel wire and parallel cannulated screws. Twelve were fixed with parallel cannulated screws, augmented with anterior titanium mesh and four screws. A custom test fixture was developed to simulate a knee flexed to 90°. A uniaxial force was applied to the simulated extensor mechanism at this angle. A non-inferiority study design was used to evaluate ultimate force required for failure of each construct as a measure of fixation strength. Stiffness of the bone/implant construct, fracture gap immediately prior to failure, and modes of failure are also reported. The mean difference in force at failure was -23.0 N (95% CI: -123.6 to 77.6N) between mesh and wire constructs, well within the pre-defined non-inferiority margin of -260 N. Mean stiffness of the mesh and wire constructs were 19.42 N/mm (95% CI: 18.57-20.27 N/mm) and 19.49 N/mm (95% CI: 18.64-20.35 N/mm), respectively. Mean gap distance for the mesh constructs immediately prior to failure was 2.11 mm (95% CI: 1.35-2.88 mm) and 3.87 mm (95% CI: 2.60-5.13 mm) for wire constructs. Titanium mesh augmentation is not inferior to tension-band wire augmentation when comparing ultimate force required for failure in this simplified biomechanical model. Results also indicate that stiffness of the two constructs is similar but that the mesh maintains a smaller fracture gap prior to failure. The results of this study indicate that the use of titanium mesh plating augmentation as a low-profile alternative to tension-band wiring for fixation of transverse patella fractures warrants further investigation. Copyright © 2015 Elsevier Ltd. All

  10. Femoral Medialization, Fixation Failures, and Functional Outcome in Trochanteric Hip Fractures Treated With Either a Sliding Hip Screw or an Intramedullary Nail From Within a Randomized Trial.

    Science.gov (United States)

    Bretherton, Christopher P; Parker, Martyn J

    2016-12-01

    The aim of this study was to determine if femoral medialization influences residual pain and mobility and to determine if fixation method or fracture pattern influences the tendency to medialize. This study used data from within a randomized controlled trial. Peterborough City Hospital, UK. Eight hundred forty-four patients presenting with a trochanteric hip fracture were randomized. Five hundred thirty-eight were available for 1-year follow-up. Fractures were classified according to OTA/AO classification as 31 A1, A2, and A3. Randomized to fixation with a Targon proximal femoral nail or sliding hip screw (SHS). Femoral medialization was calculated from follow-up x-rays at a minimum of 28 days post-fixation. Pain and mobility scores were assessed at 1 year by an independent blinded observer. Fixation failure and revision procedures were assessed at a minimum of 1 year from injury. Patients with >50% medialization had worse pain (P = 0.012) and mobility scores (P = 0.013) at 1 year. They also had more fracture healing complications (P = 0.021) and required more revision procedures (P = 0.014). Fractures treated with SHS were more likely to medialize >50% compared with intramedullary nail (P fractures were more likely to medialize, and A3 fractures were more likely to undergo >50% medialization (P fractures treated with SHS to undergo femoral medialization and correlates this with worse functional outcomes. It supports the use of intramedullary nails for A3 fractures, which have a significant tendency to medialize. Prognostic level II. See Instructions for Authors for a complete description of levels of evidence.

  11. Heart Failure as an Aging-Related Phenotype.

    Science.gov (United States)

    Morita, Hiroyuki; Komuro, Issei

    2018-01-27

    The molecular pathophysiology of heart failure, which is one of the leading causes of mortality, is not yet fully understood. Heart failure can be regarded as a systemic syndrome of aging-related phenotypes. Wnt/β-catenin signaling and the p53 pathway, both of which are key regulators of aging, have been demonstrated to play a critical role in the pathogenesis of heart failure. Circulating C1q was identified as a novel activator of Wnt/β-catenin signaling, promoting systemic aging-related phenotypes including sarcopenia and heart failure. On the other hand, p53 induces the apoptosis of cardiomyocytes in the failing heart. In these molecular mechanisms, the cross-talk between cardiomyocytes and non-cardiomyocytes (e,g,. endothelial cells, fibroblasts, smooth muscle cells, macrophages) deserves mentioning. In this review, we summarize recent advances in the understanding of the molecular pathophysiology underlying heart failure, focusing on Wnt/β-catenin signaling and the p53 pathway.

  12. Percutaneous Fixation of Anterior Column Acetabular Fracture in a Renal Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Halil Ceylan

    2013-01-01

    Full Text Available Renal transplantation, performed per million population, ranges from 30 to 60 in developed countries. The transplanted kidney is generally placed in iliac fossa; therefore the treatment procedure of the pelvic trauma in these patients should be selected carefully. The gold standard technique for the treatment of displaced acetabulum fractures is open reduction and internal fixation. Our patient had received a living-related-donor renal transplant due to chronic renal failure. In the second year of transplantation, she had been injured in a motor-vehicle accident, and radiographs showed a right acetabular anterior column fracture and left pubic rami fractures. The patient was treated with percutaneous fixation techniques and at one year of postoperative period there was no evidence of degenerative signs and the clinical outcome was good. Beside having the advantage of avoiding dissection through the iliac fossa by the standard ilioinguinal approach, percutaneous techniques, with shorter surgical time, decreasing soft tissue disruption, and the potential for early discharge from hospital might be ideal for a renal transplant recipient carrying a higher risk of infection. Percutaneous fixation of selected acetabular fractures in a renal transplant recipient would presumably have the potential to decrease the morbidity associated with traditional open surgical procedures.

  13. Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

    Science.gov (United States)

    Osterhoff, Georg; Dodd, Andrew E; Unno, Florence; Wong, Angus; Amiri, Shahram; Lefaivre, Kelly A; Guy, Pierre

    2016-11-01

    Sacroiliac screw fixation in elderly patients with pelvic fractures is prone to failure owing to impaired bone quality. Cement augmentation has been proposed as a possible solution, because in other anatomic areas this has been shown to reduce screw loosening. However, to our knowledge, this has not been evaluated for sacroiliac screws. We investigated the potential biomechanical benefit of cement augmentation of sacroiliac screw fixation in a cadaver model of osteoporotic bone, specifically with respect to screw loosening, construct survival, and fracture-site motion. Standardized complete sacral ala fractures with intact posterior ligaments in combination with ipsilateral upper and lower pubic rami fractures were created in osteoporotic cadaver pelves and stabilized by three fixation techniques: sacroiliac (n = 5) with sacroiliac screws in S1 and S2, cemented (n = 5) with addition of cement augmentation, and transsacral (n = 5) with a single transsacral screw in S1. A cyclic loading protocol was applied with torque (1.5 Nm) and increasing axial force (250-750 N). Screw loosening, construct survival, and sacral fracture-site motion were measured by optoelectric motion tracking. A sample-size calculation revealed five samples per group to be required to achieve a power of 0.80 to detect 50% reduction in screw loosening. Screw motion in relation to the sacrum during loading with 250 N/1.5 Nm was not different among the three groups (sacroiliac: 1.2 mm, range, 0.6-1.9; cemented: 0.7 mm, range, 0.5-1.3; transsacral: 1.1 mm, range, 0.6-2.3) (p = 0.940). Screw subsidence was less in the cemented group (3.0 mm, range, 1.2-3.7) compared with the sacroiliac (5.7 mm, range, 4.7-10.4) or transsacral group (5.6 mm, range, 3.8-10.5) (p = 0.031). There was no difference with the numbers available in the median number of cycles needed until failure; this was 2921 cycles (range, 2586-5450) in the cemented group, 2570 cycles (range, 2500-5107) for the sacroiliac specimens, and

  14. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  15. Standard guide for corrosion-related failure analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers key issues to be considered when examining metallic failures when corrosion is suspected as either a major or minor causative factor. 1.2 Corrosion-related failures could include one or more of the following: change in surface appearance (for example, tarnish, rust, color change), pin hole leak, catastrophic structural failure (for example, collapse, explosive rupture, implosive rupture, cracking), weld failure, loss of electrical continuity, and loss of functionality (for example, seizure, galling, spalling, swelling). 1.3 Issues covered include overall failure site conditions, operating conditions at the time of failure, history of equipment and its operation, corrosion product sampling, environmental sampling, metallurgical and electrochemical factors, morphology (mode) or failure, and by considering the preceding, deducing the cause(s) of corrosion failure. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibili...

  16. Implant failure in lower limb long bone diaphyseal fractures at a tertiary hospital in Ile- Ife. Nigeria.

    Science.gov (United States)

    Esan, O; Ikem, I C; Orimolade, E A; Esan, O T

    2014-06-01

    This included determining aetiology of failure and comparing the failure rate in implant fixations using solid intramedullary nail and DCP. A retrospective study conducted at the Orthopaedic Department, Obafemi Awolowo University Teaching Hospital, Ile-Ife,Nigeria. Records of all operated cases of lower limb long bone diaphyseal fractures including those with failed fixations from August 2006-July 2011 were reviewed. Data retrieved included type of implant used, aetiology and characteristics of Implant failure. Data were analysed using SPSS version 16. Frequency distribution of the variables of interest was done. Difference in failure rate of intramedullary nail versus DCP was tested using chi-square. Statistical significance was inferred at pfractures and met inclusion criteria, of which 135 had intramedullary nail fixation and 86 had DCP. The rate of implant failure in intramedullary nail was 1.5% while it was 5.8% in patients with DCP (p=0.113; 0R=4.10; 95% CI=0.65- 43.77). Implant fracture was the commonest type of failure seen (100% versus 60%) and non union was the commonest cause of failure seen (50% versus 40%) in the intramedullary nailing and DCP groups respectively. The likelihood of a failed implant is higher in fixations done with DCP compared with intramedullary nail though the difference was not statistically significant. Commonest reason for failure in both groups was non-union. Findings from this study may guide surgeons in choice of implant in the management of long bone fractures.

  17. Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes.

    Science.gov (United States)

    Anwar, Adeel; Lv, Decheng; Zhao, Zhi; Zhang, Zhen; Lu, Ming; Nazir, Muhammad Umar; Qasim, Wasim

    2017-04-01

    Appropriate fixation method for the posterior malleolar fractures (PMF) according to the fracture size is still not clear. Aim of this study was to evaluate the outcomes of the different fixation methods used for fixation of PMF by finite element analysis (FEA) and to compare the effect of fixation constructs on the size of the fracture computationally. Three dimensional model of the tibia was reconstructed from computed tomography (CT) images. PMF of 30%, 40% and 50% fragment sizes were simulated through computational processing. Two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior buttress plate were analysed for three different fracture volumes. The simulated loads of 350N and 700N were applied to the proximal tibial end. Models were fixed distally in all degrees of freedom. In single limb standing condition, the posterior plate group produced the lowest relative displacement (RD) among all the groups (0.01, 0.03 and 0.06mm). Further nodal analysis of the highest RD fracture group showed a higher mean displacement of 4.77mm and 4.23mm in AP and PA lag screws model (p=0.000). The amounts of stress subjected to these implants, 134.36MPa and 140.75MPa were also significantly lower (p=0.000). There was a negative correlation (p=0.021) between implant stress and the displacement which signifies a less stable fixation using AP and PA lag screws. Progressively increasing fracture size demands more stable fixation construct because RD increases significantly. Posterior buttress plate produces superior stability and lowest RD in PMF models irrespective of the fragment size. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Triple pelvic ring fixation in patients with severe pregnancy-related low back and pelvic pain.

    NARCIS (Netherlands)

    Zwienen, C.M. van; Bosch, E.W. van den; Snijders, C.J.; Vugt, A.B. van

    2004-01-01

    STUDY DESIGN: Single-group prospective follow-up study. OBJECTIVES: To assess the functional outcome of internal fixation of the pelvic ring in patients with severe pregnancy-related low back and pelvic pain (PLBP) in whom all other treatments failed. BACKGROUND DATA: More than half of all pregnant

  19. [Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures].

    Science.gov (United States)

    Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun

    2017-07-01

    To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

  20. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    Science.gov (United States)

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  1. Implant failure in osteosynthesis of fractures of long bones ...

    African Journals Online (AJOL)

    Patients who had open operative treatment of fractures of long bones were reviewed retrospectively to identify the incidence of and risk factors for implant failure. One hundred and five patients had open reduction and internal fixation of 117 fractures of long bones, out of which four patients suffered implant failure.

  2. Bone suture anchor fixation in the lower extremity: a review of insertion principles and a comparative biomechanical evaluation.

    Science.gov (United States)

    Scranton, Pierce E; Lawhon, S Michael; McDermott, John E

    2005-07-01

    Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.

  3. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.

    Science.gov (United States)

    Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F

    2015-02-01

    To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA

  4. Stress corrosion cracking of an aluminum alloy used in external fixation devices.

    Science.gov (United States)

    Cartner, Jacob L; Haggard, Warren O; Ong, Joo L; Bumgardner, Joel D

    2008-08-01

    Treatment for compound and/or comminuted fractures is frequently accomplished via external fixation. To achieve stability, the compositions of external fixators generally include aluminum alloy components due to their high strength-to-weight ratios. These alloys are particularly susceptible to corrosion in chloride environments. There have been several clinical cases of fixator failure in which corrosion was cited as a potential mechanism. The aim of this study was to evaluate the effects of physiological environments on the corrosion susceptibility of aluminum 7075-T6, since it is used in orthopedic external fixation devices. Electrochemical corrosion curves and alternate immersion stress corrosion cracking tests indicated aluminum 7075-T6 is susceptible to corrosive attack when placed in physiological environments. Pit initiated stress corrosion cracking was the primary form of alloy corrosion, and subsequent fracture, in this study. Anodization of the alloy provided a protective layer, but also caused a decrease in passivity ranges. These data suggest that once the anodization layer is disrupted, accelerated corrosion processes occur. (c) 2007 Wiley Periodicals, Inc.

  5. Permanganate Fixation of Plant Cells

    Science.gov (United States)

    Mollenhauer, Hilton H.

    1959-01-01

    In an evaluation of procedures explored to circumvent some of the problems of osmium tetroxide-fixation and methacrylate embedding of plant materials, excised segments of root tips of Zea mays were fixed for electron microscopy in potassium permanganate in the following treatment variations: unbuffered and veronal-acetate buffered solutions of 0.6, 2.0, and 5.0 per cent KMnO4 at pH 5.0, 6.0, 6.7, and 7.5, and temperatures of 2–4°C. and 22°C. After fixation the segments were dehydrated, embedded in epoxy resin, sectioned, and observed or photographed. The cells of the central region of the rootcap are described. The fixation procedures employing unbuffered solutions containing 2.0 to 5.0 per cent KMnO4 at a temperature of 22°C. gave particularly good preservation of cell structure and all membrane systems. Similar results were obtained using a solution containing 2.0 per cent KMnO4, buffered with veronal-acetate to pH 6.0, and a fixation time of 2 hours at 22°C. The fixation procedure utilizing veronal-acetate buffered, 0.6 per cent KMnO4 at 2–4°C. and pH 6.7 also gave relatively good preservation of most cellular constituents. However, preservation of the plasma membrane was not so good, nor was the intensity of staining so great, as that with the group of fixatives containing greater concentrations of KMnO4. The other fixation procedures did not give satisfactory preservation of fine structure. A comparison is made of cell structures as fixed in KMnO4 or OsO4. PMID:14423414

  6. Intrascleral IOL Fixation.

    Science.gov (United States)

    Jacob, Soosan

    2017-01-01

    Intrascleral sutureless intraocular lens (IOL) fixation utilizes direct haptic fixation within the sclera in eyes with deficient capsular support. This has advantages of long-term stability, good control of tilt and decentration, and lesser pseudophakodonesis. This review summarizes various techniques for intrascleral haptic fixation, results, complications, adaptations in special situations, modifications of the technique, combination surgeries, and intrascleral capsular bag fixation techniques (glued capsular hook). Copyright 2017 Asia-Pacific Academy of Ophthalmology.

  7. Right Visual Field Advantage in Parafoveal Processing: Evidence from Eye-Fixation-Related Potentials

    Science.gov (United States)

    Simola, Jaana; Holmqvist, Kenneth; Lindgren, Magnus

    2009-01-01

    Readers acquire information outside the current eye fixation. Previous research indicates that having only the fixated word available slows reading, but when the next word is visible, reading is almost as fast as when the whole line is seen. Parafoveal-on-foveal effects are interpreted to reflect that the characteristics of a parafoveal word can…

  8. Closed External Fixation for Failing or Failed Femoral Shaft Plating in a Developing Country.

    Science.gov (United States)

    Aliakbar, Adil; Witwit, Ibrahim; Al-Algawy, Alaa A Hussein

    2017-08-01

    Femoral shaft fractures are one of the common injuries that is treated by open reduction, with internal fixation by plate and screws or intramedullary nailing, which can achieve a high union rate. To evaluate the outcome of using closed external fixation to augment a failing plate; with signs of screw loosening and increasing bone/plate gap; a failed plate; broken plate; screws completely out of bone with redisplacement of fracture. A retrospective study on 18 patients, aged between 17-42 years, who presented between 6-18 weeks after initial surgical fixation, with pain, difficulty in limb function, deformity and abnormal movement at fracture site, was done. X-Rays showed plating failure with acceptable amount of callus, which unfortunately had refractured. Cases associated with infection and no radiological evidence of callus formation were excluded from this study. Closed reduction was done by manipulation, then fracture fixation by AO external fixator. The patients were encouraged for full weight bearing as early as possible with dynamization later on. Of the 18 patients who underwent external fixation after close reduction, 15 cases showed bone healing in a period between 11-18 weeks (mean of 14.27 weeks) with good alignment (Radiologically). Removal of external fixator was done followed by physical therapy thereafter. Closed external fixation for treatment of failing or failed femoral plating, achieves good success rate and has less complications, is a short time procedure, especially in a hospital with limited resources.

  9. Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall.

    Science.gov (United States)

    Ortillés, Á; Pascual, G; Peña, E; Rodríguez, M; Pérez-Köhler, B; Mesa-Ciller, C; Calvo, B; Bellón, J M

    2017-11-01

    The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Translaminar screw fixation in the lumbar spine: technique, indications, results

    OpenAIRE

    Grob, D.; Humke, T.

    1998-01-01

    Translaminar screw fixation of the lumbar spine represents a simple and effective technique for short segment fusion in the degenerative spine. Clinical experience with 173 patients who underwent translaminar screw fixation revealed a fusion rate of 94%. The indications for translaminar screw fixation as a primary fixation procedure are: segmental dysfunction, lumbar spinal stenosis with painful degenerative changes, segmental revision surgery after discectomies, and painful disc-related synd...

  11. The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study.

    Science.gov (United States)

    Meier, Steven W; Meier, Jeffrey D

    2006-11-01

    The purpose of this study was to compare the initial mechanical strength of 3 rotator cuff repair techniques. A total of 30 fresh-frozen cadaveric shoulders were prepared, and full-thickness supraspinatus tears were created. Specimens were randomized and placed into 3 groups: (1) transosseous suture technique (group I: TOS, n = 10, 6F/4M), (2) single-row suture anchor fixation (group II: SRSA, n = 10, 6F/4M), and (3) double-row suture anchor fixation (group III: DRSA, n = 10, 6F/4M). Each specimen underwent cyclic load testing from 5 N to 180 N at a rate of 33 mm/sec. The test was stopped when complete failure (repair site gap of 10 mm) or a total of 5,000 cycles was attained. Group I (TOS) failed at an average of 75.3 +/- 22.49 cycles, and group II (SRSA) at an average of 798.3 +/- 73.28 cycles; group III (DRSA) had no failures because all samples were stopped when 5,000 cycles had been completed. Fixation strength of the DRSA technique proved to be significantly greater than that of SRSA (P row suture anchor fixation was significantly stronger than was single-row repair. Therefore, double-row fixation may be superior to other techniques in that it provides a substantially stronger repair that could lead to improved biologic healing. A high incidence of incomplete healing occurs in rotator cuff repair. Use of double-row fixation may help the clinician to address some deficiencies in current methods by increasing the strength of the repair, potentially leading to improved healing rates.

  12. Corrosion-related failures in power plant condensers. Final report

    International Nuclear Information System (INIS)

    Beavers, J.A.; Agrawal, A.K.; Berry, W.E.

    1980-08-01

    A survey of the literature has been conducted for the Electric Power Research Institute on corrosion failures in surface condensers. The survey was directed toward condenser failures in pressurized water reactor (PWR) power plants but includes pertinent literature related to fossil and to other nuclear power plants. It includes literature on reported service failures and on experimental studies that impact on these failures

  13. Review on experiments relating to primary containment vessel failure

    International Nuclear Information System (INIS)

    Suzuki, Hiroyuki; Okada, Hidetoshi; Uchida, Sunsuke; Naitoh, Masanori

    2015-01-01

    Experiments regarding failures of primary containment vessels (PCVs) are reviewed and remained issues to be investigated in the future are discussed. Experiments are categorized as those relating to criteria of PCV failures and to FP releases through breaches on PCV boundaries. In the experiments categorized as those relating to criteria of PCV failures, experiments with full-scale, scale models, and compounds used for sealing are surveyed. Experiments relating to an amount of radioactive fission products (FPs) trapped at breaches on PCV boundaries are also reviewed. As remained issues to be investigated in the future, two items are pointed out: Evaluating degradation behavior of PCV boundaries exposed to temperature and pressure from the failure onset criteria to far above them, and evaluating an amount of FPs trapped at breaches on PCV boundaries. (author)

  14. Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges.

    Science.gov (United States)

    Gaudelli, Cinzia; Ménard, Jérémie; Mutch, Jennifer; Laflamme, G-Yves; Petit, Yvan; Rouleau, Dominique M

    2014-11-01

    This paper aims to determine the strongest fixation method for split type greater tuberosity fractures of the proximal humerus by testing and comparing three fixation methods: a tension band with No. 2 wire suture, a double-row suture bridge with suture anchors, and a manually contoured calcaneal locking plate. Each method was tested on eight porcine humeri. A osteotomy of the greater tuberosity was performed 50° to the humeral shaft and then fixed according to one of three methods. The humeri were then placed in a testing apparatus and tension was applied along the supraspinatus tendon using a thermoelectric cooling clamp. The load required to produce 3mm and 5mm of displacement, as well as complete failure, was recorded using an axial load cell. The average load required to produce 3mm and 5mm of displacement was 658N and 1112N for the locking plate, 199N and 247N for the double row, and 75N and 105N for the tension band. The difference between the three groups was significant (Prow (456N) and tension band (279N) (Prow (71N/mm) and tension band (33N/mm) (Pbiomechanical fixation for split type greater tuberosity fractures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Impacts of age-related failures on nuclear systems

    International Nuclear Information System (INIS)

    Meale, B.M.; Satterwhite, D.G.; Krantz, E.A.; MacDonald, P.E.

    1986-01-01

    Aging-related failure data from nine light water reactor safety, support, and power conversion systems have been extracted from an operational data base. Systems and components within the systems that are most affected by aging are identified. In addition, information on aging-related root causes of component failures has been extracted for service water and Class 1E electrical power distribution systems. Engineering insights are presented, and preliminary quantification of the importance of aging-related root causes for a service water system is provided

  16. Tightrope fixation of ankle syndesmosis injuries: clinical outcome, complications and technique modification.

    LENUS (Irish Health Repository)

    Naqvi, Gohar A

    2012-06-01

    Ankle syndesmotic injuries are complex and require anatomic reduction and fixation. Tightrope fixation is a relatively new technique and we present the largest series of syndesmosis fixation using Arthrex Tightrope™ (Naples, FL, USA).

  17. A relation to describe rate-dependent material failure.

    Science.gov (United States)

    Voight, B

    1989-01-13

    The simple relation OmegaOmega-alpha = 0, where Omega is a measurable quantity such as strain and A and alpha are empirical constants, describes the behavior of materials in terminal stages of failure under conditions of approximately constant stress and temperature. Applicable to metals and alloys, ice, concrete, polymers, rock, and soil, the relation may be extended to conditions of variable and multiaxial stress and may be used to predict time to failure.

  18. Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Konicek, John; Hanypsiak, Bryan T

    2014-02-01

    Poor-quality tendon is one of the most difficult problems the surgeon must overcome in achieving secure fixation during rotator cuff repair. A load-sharing rip-stop construct (LSRS) has recently been proposed as a method for improving fixation strength, but the biomechanical properties of this construct have not yet been examined. To compare the strength of the LSRS construct to that of single-row fixation for rotator cuff repair. Controlled laboratory study. Rotator cuff tears were created in 6 cadaveric matched-pair specimens and repaired with a single row or an LSRS. In the LSRS repair, a 2-mm suture tape was placed as an inverted mattress stitch in the rotator cuff, and sutures from 2 anchors were placed as simple stitches that passed medial to the suture tape. The suture tape limbs were secured with knotless anchors laterally before sutures were tied from the medial anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 371 ± 102 N in single-row repairs compared with 616 ± 185 N in LSRS repairs (P = .031). There was no difference in displacement with cyclic loading between the groups (3.3 ± 0.8 mm vs. 3.5 ± 1.1 mm; P = .561). In the single-row group, 4 of 6 failures occurred at the suture-tendon interface. In the LSRS group, only 1 failure occurred at the suture-tendon interface. The ultimate failure load of the LSRS construct for rotator cuff repair was 1.7 times that of a single-row construct in a cadaveric model. The LSRS rotator cuff repair construct may be useful in the repair of difficult tears such as massive tears, medial tears, and tears with tendon loss.

  19. Comparison of Outcomes of Operatively Treated Bicondylar Tibial Plateau Fractures by External Fixation and Internal Fixation

    Directory of Open Access Journals (Sweden)

    CC Chan

    2012-03-01

    Full Text Available The outcome of bicondylar tibial plateau fractures treated with either external fixation (35 patients or internal fixation (24 patients was reviewed. Outcome measures included the Rasmussen score, clinical complications, development of osteoarthritis and the requirement for total knee replacement (TKR. Twenty-two (92% anatomical reductions were achieved in the internal fixation group compared to 27 (77% in the external fixation group. Infective complications were more common in the external fixation group (9 patients, 26% due to pin tract infection. There were no deep infections in the internal fixation group. The mean Rasmussen score was not significantly different (mean score 32 in external fixation and 29 in internal fixation between the two groups and the incidence of osteoarthritis was the same in both groups. Four patients in the external fixation group underwent a TKR compared to 5 patients in the internal fixation group. Bicondylar tibial plateau fractures have similar outcomes following external or internal fixation.

  20. Comparison of Monolateral External Fixation and Internal Fixation for Skeletal Stabilisation in the Management of Small Tibial Bone Defects following Successful Treatment of Chronic Osteomyelitis.

    Science.gov (United States)

    Wang, Yicun; Jiang, Hui; Deng, Zhantao; Jin, Jiewen; Meng, Jia; Wang, Jun; Zhao, Jianning; Sun, Guojing; Qian, Hongbo

    2017-01-01

    To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled.

  1. Smaller Fixation Target Size Is Associated with More Stable Fixation and Less Variance in Threshold Sensitivity.

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    Full Text Available The aims of this randomized observational case control study were to quantify fixation behavior during standard automated perimetry (SAP with different fixation targets and to evaluate the relationship between fixation behavior and threshold variability at each test point in healthy young participants experienced with perimetry. SAP was performed on the right eyes of 29 participants using the Octopus 900 perimeter, program 32, dynamic strategy. The fixation targets of Point, Cross, and Ring were used for SAP. Fixation behavior was recorded using a wearable eye-tracking glass. All participants underwent SAP twice with each fixation target in a random fashion. Fixation behavior was quantified by calculating the bivariate contour ellipse area (BCEA and the frequency of deviation from the fixation target. The BCEAs (deg2 of Point, Cross, and Ring targets were 1.11, 1.46, and 2.02, respectively. In all cases, BCEA increased significantly with increasing fixation target size (p < 0.05. The logarithmic value of BCEA demonstrated the same tendency (p < 0.05. A positive correlation was identified between fixation behavior and threshold variability for the Point and Cross targets (ρ = 0.413-0.534, p < 0.05. Fixation behavior increased with increasing fixation target size. Moreover, a larger fixation behavior tended to be associated with a higher threshold variability. A small fixation target is recommended during the visual field test.

  2. Biological nitrogen fixation in relation to energy forest production. Progress report, 1978-1980

    Energy Technology Data Exchange (ETDEWEB)

    Clarholm, M; Granhall, U

    1981-01-01

    Different pasture legumes, Alnus incana and Myrica gale have been tested in pot experiments and field trials with respect to their use as biological N-fertilizers in relation to energy forest production. So far experiments have been mainly concerned with their establishemnts as on intercrop with Galix at a mire site with ombrotrophic peat and in two clayish arable soils. Laboratory experiments have been made to determine optimal conditions for growth and nitrogen fixation of wild and Alaska lupines in relation to varous soil amendments in the form of lime, ash, NPKMo, and Fe. A pilot experiment of the terrelations between willows and grey alder growing together in peat has been started at Uppsala.

  3. Postoperative complications associated with external skeletal fixators in cats.

    Science.gov (United States)

    Beever, Lee; Giles, Kirsty; Meeson, Richard

    2017-07-01

    The objective of this study was to quantify complications associated with external skeletal fixators (ESFs) in cats and to identify potential risk factors. A retrospective review of medical records and radiographs following ESF placement was performed. Case records of 140 cats were reviewed; fixator-associated complications (FACs) occurred in 19% of cats. The region of ESF placement was significantly associated with complication development. Complications developed most frequently in the femur (50%), tarsus (35%) and radius/ulna (33%). Superficial pin tract infection (SPTI) and implant failure accounted for 45% and 41% of all FACs, respectively. SPTI occurred more frequently in the femur, humerus and tibia, with implant failure more frequent in the tarsus. No association between breed, age, sex, weight, fracture type (open vs closed), ESF classification, number of pins per bone segment, degree of fracture load sharing, and the incidence or type of FAC was identified. No association between region of placement, breed, age, sex, weight, fracture type (open vs closed), ESF classification, number of pins per bone segment, fracture load sharing and the time to complication development was identified. Complication development is not uncommon in cats following ESF placement. The higher complication rate in the femur, tarsus and radius/ulna should be considered when reviewing options for fracture management. However, cats appear to have a lower rate of pin tract infections than dogs.

  4. A comparative finite-element analysis of bone failure and load transfer of osseointegrated prostheses fixations.

    NARCIS (Netherlands)

    Tomaszewski, P.K.; Verdonschot, N.J.J.; Bulstra, S.K.; Verkerke, G.J.

    2010-01-01

    An alternative solution to conventional stump-socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Goteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lubeck,

  5. A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations

    NARCIS (Netherlands)

    Tomaszewski, P. K.; Verdonschot, N.; Bulstra, S. K.; Verkerke, G. J.

    An alternative solution to conventional stump-socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Goteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lubeck,

  6. Mesopelagic N2 Fixation Related to Organic Matter Composition in the Solomon and Bismarck Seas (Southwest Pacific.

    Directory of Open Access Journals (Sweden)

    Mar Benavides

    Full Text Available Dinitrogen (N2 fixation was investigated together with organic matter composition in the mesopelagic zone of the Bismarck (Transect 1 and Solomon (Transect 2 Seas (Southwest Pacific. Transparent exopolymer particles (TEP and the presence of compounds sharing molecular formulae with saturated fatty acids and sugars, as well as dissolved organic matter (DOM compounds containing nitrogen (N and phosphorus (P were higher on Transect 1 than on Transect 2, while oxygen concentrations showed an opposite pattern. N2 fixation rates (up to ~1 nmol N L-1 d-1 were higher in Transect 1 than in Transect 2, and correlated positively with TEP, suggesting a dependence of diazotroph activity on organic matter. The scores of the multivariate ordination of DOM molecular formulae and their relative abundance correlated negatively with bacterial abundances and positively with N2 fixation rates, suggesting an active bacterial exploitation of DOM and its use to sustain diazotrophic activity. Sequences of the nifH gene clustered with Alpha-, Beta-, Gamma- and Deltaproteobacteria, and included representatives from Clusters I, III and IV. A third of the clone library included sequences close to the potentially anaerobic Cluster III, suggesting that N2 fixation was partially supported by presumably particle-attached diazotrophs. Quantitative polymerase chain reaction (qPCR primer-probe sets were designed for three phylotypes and showed low abundances, with a phylotype within Cluster III at up to 103 nifH gene copies L-1. These results provide new insights into the ecology of non-cyanobacterial diazotrophs and suggest that organic matter sustains their activity in the mesopelagic ocean.

  7. Using field feedback to estimate failure rates of safety-related systems

    International Nuclear Information System (INIS)

    Brissaud, Florent

    2017-01-01

    The IEC 61508 and IEC 61511 functional safety standards encourage the use of field feedback to estimate the failure rates of safety-related systems, which is preferred than generic data. In some cases (if “Route 2_H” is adopted for the 'hardware safety integrity constraints”), this is even a requirement. This paper presents how to estimate the failure rates from field feedback with confidence intervals, depending if the failures are detected on-line (called 'detected failures', e.g. by automatic diagnostic tests) or only revealed by proof tests (called 'undetected failures'). Examples show that for the same duration and number of failures observed, the estimated failure rates are basically higher for “undetected failures” because, in this case, the duration observed includes intervals of time where it is unknown that the elements have failed. This points out the need of using a proper approach for failure rates estimation, especially for failures that are not detected on-line. Then, this paper proposes an approach to use the estimated failure rates, with their uncertainties, for PFDavg and PFH assessment with upper confidence bounds, in accordance with IEC 61508 and IEC 61511 requirements. Examples finally show that the highest SIL that can be claimed for a safety function can be limited by the 90% upper confidence bound of PFDavg or PFH. The requirements of the IEC 61508 and IEC 61511 relating to the data collection and analysis should therefore be properly considered for the study of all safety-related systems. - Highlights: • This paper deals with requirements of the IEC 61508 and IEC 61511 for using field feedback to estimate failure rates of safety-related systems. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are detected on-line. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are only revealed by

  8. A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations.

    NARCIS (Netherlands)

    Tomaszewski, P.K.; Verdonschot, Nicolaas Jacobus Joseph; Bulstra, S.K.; Verkerke, Gijsbertus Jacob

    2010-01-01

    An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck,

  9. Eighth international congress on nitrogen fixation

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.

  10. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    Science.gov (United States)

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Sliding-screw plate fixation of proximal femoral fractures: Radiographic assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sartoris, D.J.; Resnick, D.; Kerr, R.; Goergen, T.

    1985-07-01

    The sliding compression screw-sideplate combination is currently the most widely employed device for internal fixation of stable and unstable intertrochanteric fractures of the femur. The normal and abnormal radiographic appearances of this device in the immediate post-operative period are discussed. Potential long-term complications including mal- or non-union, intra-articular penetration, metal failure, rotation of the proximal fracture fragment, disengagement, trochanteric bursitis, leg length discrepancy, delayed cervical stress fracture, and ischemic necrosis are reviewed.

  12. Sliding-screw plate fixation of proximal femoral fractures: Radiographic assessment

    International Nuclear Information System (INIS)

    Sartoris, D.J.; Resnick, D.; California Univ., San Diego, La Jolla; Kerr, R.; Goergen, T.

    1985-01-01

    The sliding compression screw-sideplate combination is currently the most widely employed device for internal fixation of stable and unstable intertrochanteric fractures of the femur. The normal and abnormal radiogrpahic appearances of this device in the immediate post-operative period are discussed. Potential long-term complications including mal- or non-union, intra-articular penetration, metal failure, rotation of the proximal fracture fragment, disengagement, trochanteric bursitis, leg length discrepancy, delayed cervical stress fracture, and ischemic necrosis are reviewed. (orig.)

  13. Isotopes in biological dinitrogen fixation

    Energy Technology Data Exchange (ETDEWEB)

    1978-10-01

    Nineteen papers were presented at the conference. Some topics discussed are as follows: biochemistry and genetics of dinitrogen fixation; genetics of the Rhizobium-legume symbiosis and of the nitrogen-fixing bacteria; studies on nonsymbiotic dinitrogen fixation in grass-bacteria associations and blue--green algae; use of /sup 15/N and /sup 13/N for the assay of dinitrogen fixation; effects of management practices on dinitrogen fixation; economy of C and N in nitrogen-fixing legumes; and survey of international and national programs on dinitrogen fixation. (HLW)

  14. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  15. Comparison of skeletal stability after sagittal split ramus osteotomy among mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation using absorbable plates and screws.

    Science.gov (United States)

    Ueki, Koichiro; Moroi, Akinori; Yoshizawa, Kunio; Hotta, Asami; Tsutsui, Takamitsu; Fukaya, Kenichi; Hiraide, Ryota; Takayama, Akihiro; Tsunoda, Tatsuta; Saito, Yuki

    2017-02-01

    The purpose of this study was to examine skeletal stability and plate breakage after sagittal split ramus osteotomy (SSRO) with the mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation techniques using absorbable plates and screws. A total of 76 Japanese patients diagnosed with mandibular prognathism with and without maxillary deformity were divided into 3 groups randomly. A total of 28 patients underwent SSRO with mono-cortical plate fixation, 23 underwent SSRO with bi-cortical plate fixation, and 25 underwent SSRO with hybrid fixation. Skeletal stability and horizontal condylar angle were analyzed by axial, frontal, and lateral cephalograms from before the operation to 1 year postoperatively. Breakage of the plate and screws was observed by 3-dimensional computed tomography (3DCT) immediately after surgery and after 1 year. Although there was a significant difference between the mono-cortical plate fixation group and hybrid fixation group regarding right MeAg in T1 (P = 0.0488) and occlusal plane in T1 (P = 0.0346), there were no significant differences between the groups for the other measurements in each time interval. In 2 cases, namely, 6 sides in the mono-cortical plate fixation group, breakage of the absorbable plate was found by 3DCT. However, there was no breakage in the bi-cortical plate fixation group and hybrid fixation group. This study results suggested that there were no significant differences in the postoperative skeletal stability among the 3 groups, and bi-cortical fixation as well as hybrid fixation was a reliable and useful method to prevent plate breakage even if an absorbable material was used. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Novel anterior cruciate ligament graft fixation device reduces slippage

    Directory of Open Access Journals (Sweden)

    Lopez MJ

    2013-05-01

    confirm that initial graft slippage is lower with GG versus BP extracortical hamstring graft tibial fixation. In addition, postoperative recovery and joint stability are more consistent with the GG. This information supports the GG as an alternative to extracortical tibial hamstring graft fixation that has procedural advantages over current implants and reduces graft failure from slippage.Keywords: cruciate, implant, bioabsorbable, canine, graft, tibia

  17. Stress analysis of implant-bone fixation at different fracture angle

    Science.gov (United States)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  18. Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss

    NARCIS (Netherlands)

    Tomaszewski, P. M.; van Diest, M.; Bulstra, S. K.; Verdonschot, N.; Verkerke, G. J.

    2012-01-01

    Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system. Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining

  19. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    Science.gov (United States)

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  20. Fixations on objects in natural scenes: dissociating importance from salience

    Directory of Open Access Journals (Sweden)

    Bernard Marius e’t Hart

    2013-07-01

    Full Text Available The relation of selective attention to understanding of natural scenes has been subject to intense behavioral research and computational modeling, and gaze is often used as a proxy for such attention. The probability of an image region to be fixated typically correlates with its contrast. However, this relation does not imply a causal role of contrast. Rather, contrast may relate to an object’s importance for a scene, which in turn drives attention. Here we operationalize importance by the probability that an observer names the object as characteristic for a scene. We modify luminance contrast of either a frequently named (common/important or a rarely named (rare/unimportant object, track the observers’ eye movements during scene viewing and ask them to provide keywords describing the scene immediately after.When no object is modified relative to the background, important objects draw more fixations than unimportant ones. Increases of contrast make an object more likely to be fixated, irrespective of whether it was important for the original scene, while decreases in contrast have little effect on fixations. Any contrast modification makes originally unimportant objects more important for the scene. Finally, important objects are fixated more centrally than unimportant objects, irrespective of contrast.Our data suggest a dissociation between object importance (relevance for the scene and salience (relevance for attention. If an object obeys natural scene statistics, important objects are also salient. However, when natural scene statistics are violated, importance and salience are differentially affected. Object salience is modulated by the expectation about object properties (e.g., formed by context or gist, and importance by the violation of such expectations. In addition, the dependence of fixated locations within an object on the object’s importance suggests an analogy to the effects of word frequency on landing positions in reading.

  1. Fatal outcome after insufficient spine fixation for pyogenic thoracic spondylodiscitis: an imperative for 360° fusion of the infected spine

    Directory of Open Access Journals (Sweden)

    Moore Ernest E

    2009-02-01

    Full Text Available Abstract Background Pyogenic spondylodiscitis represents a potentially life-threatening condition. Due to the low incidence, evidence-based surgical recommendations in the literature are equivocal, and the treatment modalities remain controversial. Case presentation A 59 year-old patient presented with a history of thoracic spondylodiscitis resistant to antibiotic treatment for 6 weeks, progressive severe back pain, and a new onset of bilateral lower extremity weakness. Clinically, the patient showed a deteriorating spastic paraparesis of her lower extremities. An emergent MRI revealed a kyphotic wedge compression fracture at T7/T8 with significant spinal cord compression, paravertebral and epidural abscess, and signs of myelopathy. The patient underwent surgical debridement with stabilization of the anterior column from T6–T9 using an expandable titanium cage, autologous bone graft, and an anterolateral locking plate. The patient recovered well under adjunctive antibiotic treatment. She presented again to the emergency department 6 months later, secondary to a repeat fall, with acute paraplegia of the lower extremities and radiographic evidence of failure of fixation of the anterior T-spine. She underwent antero-posterior revision fixation with hardware removal, correction of kyphotic malunion, evacuation of a recurrent epidural abscess, decompression of the spinal canal, and 360° fusion from T2–T11. Despite the successful salvage procedure, the patient deteriorated in the postoperative phase, when she developed multiple complications including pneumonia, acute respiratory distress syndrome, bacterial meningitis, abdominal compartment syndrome, followed by septic shock with multiple organ failure and a lethal outcome within two weeks after revision surgery. Conclusion This catastrophic example of a lethal outcome secondary to failure of anterior column fixation for pyogenic thoracic spondylodiscitis underlines the notion that surgical

  2. Efference copy failure during smooth pursuit eye movements in schizophrenia.

    Science.gov (United States)

    Spering, Miriam; Dias, Elisa C; Sanchez, Jamie L; Schütz, Alexander C; Javitt, Daniel C

    2013-07-17

    Abnormal smooth pursuit eye movements in patients with schizophrenia are often considered a consequence of impaired motion perception. Here we used a novel motion prediction task to assess the effects of abnormal pursuit on perception in human patients. Schizophrenia patients (n = 15) and healthy controls (n = 16) judged whether a briefly presented moving target ("ball") would hit/miss a stationary vertical line segment ("goal"). To relate prediction performance and pursuit directly, we manipulated eye movements: in half of the trials, observers smoothly tracked the ball; in the other half, they fixated on the goal. Strict quality criteria ensured that pursuit was initiated and that fixation was maintained. Controls were significantly better in trajectory prediction during pursuit than during fixation, their performance increased with presentation duration, and their pursuit gain and perceptual judgments were correlated. Such perceptual benefits during pursuit may be due to the use of extraretinal motion information estimated from an efference copy signal. With an overall lower performance in pursuit and perception, patients showed no such pursuit advantage and no correlation between pursuit gain and perception. Although patients' pursuit showed normal improvement with longer duration, their prediction performance failed to benefit from duration increases. This dissociation indicates relatively intact early visual motion processing, but a failure to use efference copy information. Impaired efference function in the sensory system may represent a general deficit in schizophrenia and thus contribute to symptoms and functional outcome impairments associated with the disorder.

  3. Looking good, but behaving badly: leader accountability and ethics failure.

    Science.gov (United States)

    Bruhn, John G

    2005-01-01

    Making the bottom line is a fact of life in the business and corporate world. However, when organizations and their leaders become fixated on the bottom line and ignore values, an environment conducive to ethics failure is nurtured. Ethics failure has focused almost exclusively on the behavior of organizational leaders. However, it is the interaction of the culture of organizations and the character of their leaders that create the environment and social situations conducive to ethics failure. Although ethics failure is not totally preventable, there are usually warning signs early in the recruitment process of prospective CEOs that predict ethics failure. The author suggests that specific up-front questions be asked to ascertain the ethical fitness of prospective CEOs.

  4. Results of application of external fixation with different types of fixators

    Directory of Open Access Journals (Sweden)

    Grubor Predrag

    2012-01-01

    Full Text Available Introduction. Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. Objective. The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov had the best biomechanical properties in primary stabilization of spiral, transverse and commutative bone fractures. Methods. To determine the investigation methodology of biomechanical characteristics of the external fixator we used mathematical and computer simulator (software, juvidur physical model and clinical examination. Results. Values of advancing fragments in millimetres obtained by the study of mathematical and computer simulator (software: Charnley - 0.080 mm, Mitković M 20 - 0.785 mm, Ilizarov - 2.245 mm and Ortofix - 1.400 mm. In testing the juvidur model the following values were obtained: the external fixator Mitković M20 - 1.380 mm, Ortofix - 1.470 mm, Ilizarov - 2.410 mm, and Charnley - 2.510 mm. Clinical research of biomechanical characteristics of the effect of vertical force yielded the following results: Mitković M20 - 0.89 mm, Ortofix - 0.14 mm, Charnley - 0.80 mm and Ilizarov - 1.23 mm. Conclusion. When determining the total number of the stability test splints under the effect of vertical force (compression and force effect in antero-posterior, later-lateral plane of cross, spiral and comminuted long bone fractures, the best unified biomechanical stability was shown by the following external fixators: firstly, Mitković M20 (0.93mm, secondly, Charnley fixator (1.14 mm, thirdly, Ortofix (1.22 mm, and fourthly, Ilizarov (1.60 mm.

  5. Single versus double row suture anchor fixation for greater tuberosity fractures - a biomechanical study.

    Science.gov (United States)

    Seppel, Gernot; Saier, Tim; Martetschläger, Frank; Plath, Johannes E; Guevara-Alvarez, Alberto; Henschel, Julia; Winkler, Martin; Augat, Peter; Imhoff, Andreas B; Buchmann, Stefan

    2017-12-01

    Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Load to failure values were higher in the DR group (649 N; ±176) than in the SR group (490 N; ±145) however without statistical significance (p = .12). In greater tuberosity displacement of 3-5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; ±46 compared to 260 N; ±62 in the DR group (p = .65). The results suggest that both techniques are viable options for refixation of greater tuberosity fractures. Laboratory study.

  6. Radiographic failure and rates of re-operation after acromioclavicular joint reconstruction: a comparison of surgical techniques.

    Science.gov (United States)

    Spencer, H T; Hsu, L; Sodl, J; Arianjam, A; Yian, E H

    2016-04-01

    To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. ©2016 The British Editorial

  7. Removal of internal fixation--the effect on patients' complaints: a study of 66 cases of removal of internal fixation after malleolar fractures

    DEFF Research Database (Denmark)

    Jacobsen, S; Honnens de Lichtenberg, M; Jensen, C M

    1994-01-01

    To estimate the effect of removal of internal fixation after treatment of malleolar fractures on postoperatively presented complaints, we retrospectively evaluated 66 patients by their records and by personal questionnaires. Of all the patients, 89.4% had one or more complaints. These were...... typically soreness over implant and cicatrix, reduced movement of the ankle joint, and strain-related pain. About 75% of these patients reported improvement after removal. The AO mode of fixation, i.e., typically by lateral semitubular plating and transsyndesmotic screw and a medial screw or pins...... period. We conclude that removal of internal fixation after malleolar fractures is indicated when common types of complaints are presented....

  8. Surgical treatment of neglected clubfoot using external fixator

    Directory of Open Access Journals (Sweden)

    Rodrigo Mota Pacheco Fernandes

    Full Text Available ABSTRACT The definition of neglected clubfoot (NC includes a variable range of complex deformities of the foot that are refractory to conventional treatments or are treated inappropriately. Several etiologies may be related to this. The Ilizarov method has become established as a tool for treating these deformities. It minimizes soft-tissue damage through gradual correction of the deformity, with a high success rate in relation to achieving a plantigrade foot, with low incidence of recurrence. The indications for treatment include severe rigid deformities (Dimeglio III and IV, or adverse skin conditions. Careful clinical and radiological examination is fundamental for proper planning and installation of the external fixator. The techniques used include selection of external fixation assemblies, which can be closed when there is a connection between the leg, hindfoot and forefoot. This closed assembly may or may not be constricted, according to whether hinges are provided or whether use of the natural anatomical hinges during correction of the deformity is envisaged. An open assembly makes it possible to add flexibility to the foot through histogenesis, while allowing closed corrections of greater precision later on. Hexapod fixators are an innovation with high potential for accuracy in correcting deformities. Procedures associated with external fixation include soft-tissue release and bone procedures. These procedures enable corrections that are more anatomical, for different degrees of severity and stiffness of deformity. It can be concluded from analyzing this case series that treatment of neglected clubfoot using an external fixator has a high rate of good and excellent results, with low frequency of complications.

  9. Feasibility of purely endoscopic intramedullary fixation of mandibular condyle fractures.

    Science.gov (United States)

    Frake, Paul C; Goodman, Joseph F; Joshi, Arjun S

    2015-01-01

    The investigators of this study hypothesized that fractures of the mandibular condyle can be repaired using short-segment intramedullary implants and purely endoscopic surgical technique, using a basic science, human cadaver model in an academic center. Endoscopic instrumentation was used through a transoral mucosal incision to place intramedullary implants of 2 cm in length into osteotomized mandibular condyles. The surgical maneuvers that required to insert these implants, including condyle positioning, reaming, implant insertion, and seating of the mandibular ramus, are described herein. Primary outcome was considered as successful completion of the procedure. Ten cadaveric mandibular condyles were successfully repaired with rigid intramedullary internal fixation without the use of external incisions. Both insertion of a peg-type implant and screwing a threaded implant into the condylar head were possible. The inferior portion of the implant remained exposed, and the ramus of the mandible was manipulated into position on the implant using retraction at the sigmoid notch. The results of this study suggest that purely endoscopic repair of fractures of the mandibular condyle is possible by using short-segment intramedullary titanium implants and a transoral endoscopic approach without the need for facial incisions or punctures. The biomechanical advantages of these intramedullary implants, including improved strength and resistance to mechanical failure compared with miniplates, have been recently established. The combination of improved implant design and purely endoscopic technique may allow for improved fixation and reduced surgical- and implant-related morbidity in the treatment of condylar fractures.

  10. Pedicle screw-rod fixation: a feasible treatment for dogs with severe degenerative lumbosacral stenosis.

    Science.gov (United States)

    Tellegen, Anna R; Willems, Nicole; Tryfonidou, Marianna A; Meij, Björn P

    2015-12-07

    Degenerative lumbosacral stenosis is a common problem in large breed dogs. For severe degenerative lumbosacral stenosis, conservative treatment is often not effective and surgical intervention remains as the last treatment option. The objective of this retrospective study was to assess the middle to long term outcome of treatment of severe degenerative lumbosacral stenosis with pedicle screw-rod fixation with or without evidence of radiological discospondylitis. Twelve client-owned dogs with severe degenerative lumbosacral stenosis underwent pedicle screw-rod fixation of the lumbosacral junction. During long term follow-up, dogs were monitored by clinical evaluation, diagnostic imaging, force plate analysis, and by using questionnaires to owners. Clinical evaluation, force plate data, and responses to questionnaires completed by the owners showed resolution (n = 8) or improvement (n = 4) of clinical signs after pedicle screw-rod fixation in 12 dogs. There were no implant failures, however, no interbody vertebral bone fusion of the lumbosacral junction was observed in the follow-up period. Four dogs developed mild recurrent low back pain that could easily be controlled by pain medication and an altered exercise regime. Pedicle screw-rod fixation offers a surgical treatment option for large breed dogs with severe degenerative lumbosacral stenosis with or without evidence of radiological discospondylitis in which no other treatment is available. Pedicle screw-rod fixation alone does not result in interbody vertebral bone fusion between L7 and S1.

  11. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P 0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  12. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    Science.gov (United States)

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  13. K-wire and tension band wire fixation in treating sternoclavicular joint dislocation

    Directory of Open Access Journals (Sweden)

    CHEN Qing-yu

    2011-02-01

    Full Text Available 【Abstract】Objective: To evaluate the feasibility and therapeutic effect of treating sternoclavicular joint dislocation by K-wire and tension band wire fixation, and to improve the safety and stability of this technique. Methods: This study consisted of 9 cases, 6 males and 3 females with the mean age of 25 years (range, 9-62 years. The causes were traffic accident in 7 cases, falling in 1 case and fight in 1 case. The duration from injury to operation was 2 hours to 7 days. There were 5 left dislocations and 4 right dislocations; 8 anterior dislocations and 1 posterior dislocation, including one combined with left scapular fracture and one with left olecranon fracture. Open reduction and internal fixation using K-wires and tension band wires were performed to treat dislocations. Results: All patients were followed up for 6 to 24 months, 10 months on average. According to Rockwood’s rating scale on postoperative sternoclavicular joint, 8 cases achieved excellent outcomes with an average score of 13.88, and the rest case achieved a good outcome with the score of 12. Anatomical reduction was obtained in all cases. There were no such postoperative complications as severe infection, injury to blood vessel and nerve, failure of fixation, etc. Patients were all satisfied with the anatomical reduction and functional recovery. Conclusions: The technique of K-wire and tension band wire fixation is safe, simple, effective, less invasive and has been successfully used in orthopedic surgery. It is effective in treating sternoclavicular joint dislocation though it has some disadvantages. Key words: Sternoclavicular joint; Dislocations; Bone wires; Fracture fixation, internal

  14. Pediatric mandibular fractures treated by rigid internal fixation.

    Science.gov (United States)

    Wong, G B

    1993-09-01

    Mandibular fractures in the pediatric patient population are relatively uncommon. These patients present with their own unique treatment requirements. Most fractures have been treated conservatively by dental splints. Closed reduction techniques with maxillomandibular fixation (MMF) in very young children can pose several concerns, including cooperation, compliance and adequate nutritional intake. Rigid internal fixation of unstable mandibular fractures using miniplates and screws circumvents the need for MMF and allows immediate jaw mobilization. At major pediatric trauma institutions, there has been an increasing trend toward the use of this treatment when open reduction is necessary. This article presents a report of a five-year-old child who presented with bilateral mandibular fractures and was treated by rigid internal fixation and immediate mandibular mobilization.

  15. Delayed fixation of displaced bilateral, atraumatic, femoral neck fractures in a patient with pregnancy related osteomalacia.

    Science.gov (United States)

    Docker, Charles; Starks, Ian; Wade, Roger; Wynn-Jones, Charles

    2011-06-01

    We present the case of a woman diagnosed with simultaneous displaced intracapsular femoral neck fractures following the birth of her second child. No traumatic event was identified. Diagnosis was delayed as the cause of her pain was thought to be non-skeletal in origin. Radiological and serological investigations were diagnostic of osteomalacia. Surgical fixation of her fractures was further delayed due to profound hypocalcaemia. Despite the delays, fixation with bilateral dynamic hip screws resulted in union with no evidence of avascular necrosis at 2 years follow-up. We believe this to be the first report of atraumatic bilateral femoral neck fractures and it shows that a good result can be achieved even in the presence of delayed fixation.

  16. CSF coccidioides complement fixation

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003526.htm CSF coccidioides complement fixation test To use the sharing features on this page, please enable JavaScript. CSF coccidioides complement fixation is a test that checks ...

  17. A Novel Biodegradable Polycaprolactone Fixator for Osteosynthesis Surgery of Rib Fracture: In Vitro and in Vivo Study

    Directory of Open Access Journals (Sweden)

    Yi-Hsun Yu

    2015-11-01

    Full Text Available Osteosynthesis surgery for rib fractures is controversial and challenging. This study developed a noval poly(ε-caprolactone (PCL-based biodegradable “cable-tie” fixator for osteosynthesis surgery for rib fractures. A biodegradable fixator specifically for fractured ribs was designed and fabricated by a micro-injection molding machine in our laboratory. The fixator has three belts that could be passed through matching holes individually. The locking mechanism allows the belt movement to move in only one direction. To examine the in vitro biomechanical performance, ribs 3–7 from four fresh New Zealand rabbits were employed. The load to failure and stress-strain curve was compared in the three-point bending test among native ribs, titanium plate-fixed ribs, and PCL fixator-fixed ribs. In the in vivo animal study, the sixth ribs of New Zealand rabbits were osteotomized and osteosynthesis surgery was performed using the PCL fixator. Outcomes were assessed by monthly X-ray examinations, a final micro-computed tomography (CT scan, and histological analysis. The experimental results suggested that the ribs fixed with the PCL fixator were significantly less stiff than those fixed with titanium plates (p < 0.05. All ribs fixed with the PCL fixators exhibited union. The bridging callus was confirmed by gross, radiographic micro-three-dimensional (3D CT, and histological examinations. In addition, there was no significant inflammatory response of the osteotomized ribs or the PCL-rib interface during application. The novel PCL fixator developed in this work achieves satisfactory results in osteosynthesis surgery for rib fractures, and may provide potential applications in other orthopedic surgeries.

  18. Complement fixation test to C burnetii

    Science.gov (United States)

    ... complement fixation test; Coxiella burnetii - complement fixation test; C burnetii - complement fixation test ... a specific foreign substance ( antigen ), in this case, C burnetii . Antibodies defend the body against bacteria, viruses, ...

  19. Biomechanical evaluation of the impact of various facet joint lesions on the primary stability of anterior plate fixation in cervical dislocation injuries: a cadaver study: Laboratory investigation.

    Science.gov (United States)

    Oberkircher, Ludwig; Born, Sebastian; Struewer, Johannes; Bliemel, Christopher; Buecking, Benjamin; Wack, Christina; Bergmann, Martin; Ruchholtz, Steffen; Krüger, Antonio

    2014-10-01

    Injuries of the subaxial cervical spine including facet joints and posterior ligaments are common. Potential surgical treatments consist of anterior, posterior, or anterior-posterior fixation. Because each approach has its advantages and disadvantages, the best treatment is debated. This biomechanical cadaver study compared the effect of different facet joint injuries on primary stability following anterior plate fixation. Fractures and plate fixation were performed on 15 fresh-frozen intact cervical spines (C3-T1). To simulate a translation-rotation injury in all groups, complete ligament rupture and facet dislocation were simulated by dissecting the entire posterior and anterior ligament complex between C-4 and C-5. In the first group, the facet joints were left intact. In the second group, one facet joint between C-4 and C-5 was removed and the other side was left intact. In the third group, both facet joints between C-4 and C-5 were removed. The authors next performed single-level anterior discectomy and interbody grafting using bone material from the respective thoracic vertebral bodies. An anterior cervical locking plate was used for fixation. Continuous loading was performed using a servohydraulic test bench at 2 N/sec. The mean load failure was measured when the implant failed. In the group in which both facet joints were intact, the mean load failure was 174.6 ± 46.93 N. The mean load failure in the second group where only one facet joint was removed was 127.8 ± 22.83 N. In the group in which both facet joints were removed, the mean load failure was 73.42 ± 32.51 N. There was a significant difference between the first group (both facet joints intact) and the third group (both facet joints removed) (p cadaver study, primary stability of anterior plate fixation for dislocation injuries of the subaxial cervical spine was dependent on the presence of the facet joints. If the bone in one or both facet joints is damaged in the clinical setting, anterior plate

  20. Anterior fixation of the axis.

    Science.gov (United States)

    Traynelis, Vincent C; Fontes, Ricardo B V

    2010-09-01

    Although anterior fixation of the axis is not commonly performed, plate fixation of C2 is an important technique for treating select upper cervical traumatic injuries and is also useful in the surgical management of spondylosis. To report the technique and outcomes of C2 anterior plate fixation for a series of patients in which the majority presented with symptomatic degenerative spondylosis. Forty-six consecutive patients underwent single or multilevel fusions over a 7-year period; 30 of these had advanced degenerative disease manifested by myelopathy or deformity. Exposure was achieved with rostral extension of the standard anterior cervical exposure via careful soft tissue dissection, mobilization of the superior thyroid artery, and the use of a table-mounted retractor. It was not necessary to remove the submandibular gland, section the digastric muscle, or make additional skin incisions. Screws were placed an average of 4.6 mm (+/- 2.3 mm) from the inferior C2 endplate with a mean sagittal trajectory of 15.7 degrees (+/- 7.6 degrees). Short- and long-term procedure-related mortality was 4.4%, and perioperative morbidity was 8.9%. Patients remained intubated an average of 2.5 days following surgery. Dysphagia was initially reported by 15.2% of patients but resolved by the 8th postoperative week in all patients. Arthrodesis was achieved in all patients available for long-term follow-up. Multilevel fusions were not associated with longer hospitalization or morbidity. Anterior plate fixation of the axis for degenerative disease can be accomplished with acceptable morbidity employing an extension of the standard anterolateral route.

  1. [Results of femoral lengthening over an intramedullary nail and external fixator].

    Science.gov (United States)

    Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz

    2008-01-01

    Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.

  2. Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Directory of Open Access Journals (Sweden)

    Herrera Antonio

    2010-06-01

    Full Text Available Abstract Background Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw, 564,05 N (Group 2; 9 × 28, 614,95 N (Group 3; 9 × 35, 651,14 N (Group 4; 10 × 28 and 664,99 (Group 5; 10 × 35. No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P Conclusions Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm do not achieve optimal fixation and should be implanted only with special requirements.

  3. Transient improvements in fixational stability in strabismic amblyopes following bifoveal fixation and reduced interocular suppression.

    Science.gov (United States)

    Raveendran, Rajkumar Nallour; Babu, Raiju J; Hess, Robert F; Bobier, William R

    2014-03-01

    To test the hypothesis that fixational stability of the amblyopic eye in strabismics will improve when viewing provides both bifoveal fixation and reduced inter-ocular suppression by reducing the contrast to the fellow eye. Seven strabismic amblyopes (Age: 29.2 ± 9 years; five esotropes and two exotropes) showing clinical characteristics of central suppression were recruited. Interocular suppression was measured by a global motion task. For each participant, a balance point was determined which defined contrast levels for each eye where binocular combination was optimal (interocular suppression minimal). When the balance point could not be determined, this participant was excluded. Bifoveal fixation was established by ocular alignment using a haploscope. Participants dichoptically viewed similar targets (a cross of 2.3° surrounded by a square of 11.3°) at 40 cm. Target contrasts presented to each eye were either high contrast (100% to both eyes) or balanced contrast (attenuated contrast in the fellow fixing eye). Fixation stability was measured over a 5 min period and quantified using bivariate contour ellipse areas in four different binocular conditions; unaligned/high contrast, unaligned/balance point, aligned/high contrast and aligned/balance point. Fixation stability was also measured in six control subjects (Age: 25.3 ± 4 years). Bifoveal fixation in the strabismics was transient (58.15 ± 15.7 s). Accordingly, fixational stability was analysed over the first 30 s using repeated measures anova. Post hoc analysis revealed that for the amblyopic subjects, the fixational stability of the amblyopic eye was significantly improved in aligned/high contrast (p = 0.01) and aligned/balance point (p suppression. However, once initiated, bifoveal fixation is transient with the strabismic eye drifting away from foveal alignment, thereby increasing the angle of strabismus. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  4. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    Science.gov (United States)

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  5. Comparison of screw fixation with elastic fixation methods in the treatment of syndesmosis injuries in ankle fractures.

    Science.gov (United States)

    Seyhan, Mustafa; Donmez, Ferdi; Mahirogullari, Mahir; Cakmak, Selami; Mutlu, Serhat; Guler, Olcay

    2015-07-01

    17 patients with ankle syndesmosic injury were treated with a 4.5mm single cortical screw fixation (passage of screw 4 cortices) and 15 patients were treated with single-level elastic fixation material. All patients were evaluated according to the AOFAS ankle and posterior foot scale at the third, sixth and twelfth months after the fixation. The ankle range of movement was recorded together with the healthy side. The Student's t test was used for statistical comparisons. No statistical significant difference was observed between the AOFAS scores (p>0.05). The range of dorsiflexion and plantar flexion motion of the elastic fixation group at the 6th and 12th months were significantly better compared to the screw fixation group (pankle syndesmosis injuries. The unnecessary need of a second surgical intervention for removal of the fixation material is another advantageous aspect of this method of fixation. Copyright © 2015. Published by Elsevier Ltd.

  6. Complications after arthroscopic coracoclavicular reconstruction using a single adjustable-loop-length suspensory fixation device in acute acromioclavicular joint dislocation.

    Science.gov (United States)

    Shin, Sang-Jin; Kim, Nam-Ki

    2015-05-01

    The purpose of this study was to evaluate clinical and radiological outcomes after arthroscopically assisted coracoclavicular (CC) fixation using a single adjustable-loop-length suspensory fixation device for acute acromioclavicular dislocation and to report intraoperative and postoperative complications. Eighteen consecutive patients with acute acromioclavicular dislocation underwent arthroscopically assisted CC fixation using a single TightRope (Arthrex, Naples, FL). Using the Rockwood classification, 3 patients had grade III dislocations, one patient had a grade IV dislocation, and 14 patients had grade V dislocations. The preoperative CC distance of the injured shoulder was 16.1 ± 2.7 mm (range, 11.2 to 21.0 mm), and it increased by 99% ± 36% (range, 17% to 153%) on average compared with the contralateral shoulder. The average CC distance was 10.5 ± 2.5 mm (range, 7.7 to 15.5 mm), and it increased by 30% ± 30% (range, -9.4% to 90%) at the final follow-up. Compared with immediate postoperative radiographs, the CC distance was maintained in 12 patients, increased between 50% and 100% in 4 patients, and increased more than 100% in 2 patients at final follow-up. However, there was no statistical difference in Constant scores between 6 patients with reduction loss (95.6 ± 4.5) and 12 patients with reduction maintenance (98.4 ± 2.5; P = .17). Perioperative complications occurred in 8 patients, including one case of acromioclavicular arthritis, one case of delayed distal clavicular fracture at the clavicular hole of the device, 3 cases of clavicular or coracoid button failures, and 3 cases of clavicular bony erosion. Satisfactory clinical outcomes were obtained after CC fixation using the single adjustable-loop-length suspensory fixation device for acute acromioclavicular joint dislocation. However, CC fixation failure of greater than 50% of the unaffected side in radiological examinations occurred in 33% of the patients within 3 months after the operation

  7. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    Science.gov (United States)

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P  .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P  0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  8. Treatment of midshaft clavicular nonunion with plate fixation and autologous bone grafting

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Vaesel, M T; Søjbjerg, Jens Ole

    1995-01-01

    We studied the results of 16 consecutive midshaft clavicular nonunions operated on at the Shoulder and Elbow Clinic during the period from 1990 to 1993. All patients were treated with rigid 3.5 mm plate fixation and autologous cancellous bone grafting. Union of the fractures was achieved in all...... except one case, with a reconstruction ratio (restoration of bone length) of 0.96 (range 0.88 to 1.03). At follow-up 12 of 16 patients had returned to their preinjury activity level and according to the Constant score had obtained an excellent result. Two patients were graded as good, one as fair......, and one had a failure. Thirteen of 16 patients were satisfied with the cosmetic outcome, assessing their cosmetic result as either good or excellent. Rigid plate fixation and restoration of clavicular length with autologous cancellous bone graft is recommended for the treatment of symptomatic clavicular...

  9. Management and follow up of tibial plateau fractures by ′T′ clamp external fixator and limited internal fixation

    Directory of Open Access Journals (Sweden)

    Thimmegowda M

    2005-01-01

    Full Text Available Background: Tibial plateau fractures are difficult to treat especially when soft tissue is compromised by open reduction and internal fixation. Many methods have be1en tried in the past to manage these cases of which external fixation were shown to be effective as they limit the soft tissue and wound complications. Methods: Complex tibial plateau fractures of sixteen patients were treated by closed reduction, fixation of articular fragments by screws and application of unilateral external fixator. The external fixator was kept in place till fracture united clinically and radiologically. The patients were followed up for at least one year to assess the function of the knee joint Results: The average duration of external fixation was 13 weeks. All the fractures healed. Pin track infection (five patients and instability (six patients of the knee were encountered with this procedure. The average duration of follow up was 62 weeks. The mean range of motion was 1250 arc. The IOWA knee score averaged 90.3 points. Conclusions: External fixation with limited internal fixation may be effective in the management of complex tibial plateau fractures which requires further support from studies with large sample size. ′T′ clamp external fixation with limited Internal fixation is the procedure of choice when alignment, stability, early mobilisation is required in a soft tissue compromised tibial plateau fractures.

  10. Is prophylactic fixation a cost-effective method to prevent a future contralateral fragility hip fracture?

    Science.gov (United States)

    Faucett, Scott C; Genuario, James W; Tosteson, Anna N A; Koval, Kenneth J

    2010-02-01

    : A previous hip fracture more than doubles the risk of a contralateral hip fracture. Pharmacologic and environmental interventions to prevent hip fracture have documented poor compliance. The purpose of this study was to examine the cost-effectiveness of prophylactic fixation of the uninjured hip to prevent contralateral hip fracture. : A Markov state-transition model was used to evaluate the cost and quality-adjusted life-years (QALYs) for unilateral fixation of hip fracture alone (including internal fixation or arthroplasty) compared with unilateral fixation and contralateral prophylactic hip fixation performed at the time of hip fracture or unilateral fixation and bilateral hip pad protection. Prophylactic fixation involved placement of a cephalomedullary nail in the uninjured hip and was initially assumed to have a relative risk of a contralateral fracture of 1%. Health states included good health, surgery-related complications requiring a second operation (infection, osteonecrosis, nonunion, and malunion), fracture of the uninjured hip, and death. The primary outcome measure was the incremental cost-effectiveness ratio estimated as cost per QALY gained in 2006 US dollars with incremental cost-effectiveness ratios below $50,000 per QALY gained considered cost-effective. Sensitivity analyses evaluated the impact of patient age, annual mortality and complication rates, intervention effectiveness, utilities, and costs on the value of prophylactic fixation. : In the baseline analysis, in a 79-year-old woman, prophylactic fixation was not found to be cost-effective (incremental cost-effectiveness ratio = $142,795/QALY). However, prophylactic fixation was found to be a cost-effective method to prevent contralateral hip fracture in: 1) women 71 to 75 years old who had 30% greater relative risk for a contralateral fracture; and 2) women younger than age 70 years. Cost-effectiveness was greater when the additional costs of prophylaxis were less than $6000. However, for

  11. Low bone mineral density is not related to failure in femoral neck fracture patients treated with internal fixation

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Ryg, Jesper; Overgaard, Søren

    2014-01-01

    the importance of low bone mineral density (BMD). Patients and methods - 140 consecutive patients (105 females, median age 80) treated with IF had a dual-energy X-ray absorptiometry (DXA) scan of the hip performed median 80 days after treatment. The patients' radiographs were evaluated for fracture displacement......, implant positioning, and quality of reduction. From a questionnaire completed during admission, 2 variables for comorbidity and walking disability were chosen. Primary outcome was low hip BMD (amount of mineral matter per square centimeter of hip bone) compared to hip failure (resection, arthroplasty...

  12. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    Science.gov (United States)

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Stimulation of nitrogen fixation in soddy-podzolic soils with fungi

    Science.gov (United States)

    Kurakov, A. V.; Prokhorov, I. S.; Kostina, N. V.; Makhova, E. G.; Sadykova, V. S.

    2006-09-01

    Stimulation of nitrogen fixation in soddy-podzolic soils is related to the hydrolytic activity of fungi decomposing plant polymers. It was found that the rate of nitrogen fixation upon the simultaneous inoculation of the strains of nitrogen-fixing bacteria Bacillus cereus var. mycoides and the cellulolytic fungus Trichoderma asperellum into a sterile soil enriched with cellulose or Jerusalem artichoke residues is two to four times higher than upon the inoculation of the strains of Bacillus cereus var. mycoides L1 only. The increase in the nitrogen fixation depended on the resistance of the substrates added into the soil to fungal hydrolysis. The biomass of the fungi decomposing plant polymers increased by two-four times. The nitrogen-fixing activity of the soil decreased when the growth of the fungi was inhibited with cycloheximide, which attested to a close correlation between the intensity of the nitrogen fixation and the decomposition of the plant polymers by fungi. The introduction of an antifungal antibiotic, together with starch or with plant residues, significantly (by 60-90%) decreased the rate of nitrogen fixation in the soll.

  14. Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure

    Science.gov (United States)

    Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark

    2015-01-01

    Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAPTM Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure. PMID:26240834

  15. Vertebral body spread in thoracolumbar burst fractures can predict posterior construct failure.

    Science.gov (United States)

    De Iure, Federico; Lofrese, Giorgio; De Bonis, Pasquale; Cultrera, Francesco; Cappuccio, Michele; Battisti, Sofia

    2018-06-01

    The load sharing classification (LSC) laid foundations for a scoring system able to indicate which thoracolumbar fractures, after short-segment posterior-only fixations, would need longer instrumentations or additional anterior supports. We analyzed surgically treated thoracolumbar fractures, quantifying the vertebral body's fragment displacement with the aim of identifying a new parameter that could predict the posterior-only construct failure. This is a retrospective cohort study from a single institution. One hundred twenty-one consecutive patients were surgically treated for thoracolumbar burst fractures. Grade of kyphosis correction (GKC) expressed radiological outcome; Oswestry Disability Index and visual analog scale were considered. One hundred twenty-one consecutive patients who underwent posterior fixation for unstable thoracolumbar burst fractures were retrospectively evaluated clinically and radiologically. Supplementary anterior fixations were performed in 34 cases with posterior instrumentation failure, determined on clinic-radiological evidence or symptomatic loss of kyphosis correction. Segmental kyphosis angle and GKC were calculated according to the Cobb method. The displacement of fracture fragments was obtained from the mean of the adjacent end plate areas subtracted from the area enclosed by the maximum contour of vertebral fragmentation. The "spread" was derived from the ratio between this subtraction and the mean of the adjacent end plate areas. Analysis of variance, Mann-Whitney, and receiver operating characteristic were performed for statistical analysis. The authors report no conflict of interest concerning the materials or methods used in the present study or the findings specified in this paper. No funds or grants have been received for the present study. The spread revealed to be a helpful quantitative measurement of vertebral body fragment displacement, easily reproducible with the current computed tomography (CT) imaging technologies

  16. The role of eye fixation in memory enhancement under stress - An eye tracking study.

    Science.gov (United States)

    Herten, Nadja; Otto, Tobias; Wolf, Oliver T

    2017-04-01

    In a stressful situation, attention is shifted to potentially relevant stimuli. Recent studies from our laboratory revealed that participants stressed perform superior in a recognition task involving objects of the stressful episode. In order to characterize the role of a stress induced alteration in visual exploration, the present study investigated whether participants experiencing a laboratory social stress situation differ in their fixation from participants of a control group. Further, we aimed at shedding light on the relation of fixation behaviour with obtained memory measures. We randomly assigned 32 male and 31 female participants to a control or a stress condition consisting of the Trier Social Stress Test (TSST), a public speaking paradigm causing social evaluative threat. In an established 'friendly' control condition (f-TSST) participants talk to a friendly committee. During both conditions, the committee members used ten office items (central objects) while another ten objects were present without being used (peripheral objects). Participants wore eye tracking glasses recording their fixations. On the next day, participants performed free recall and recognition tasks involving the objects present the day before. Stressed participants showed enhanced memory for central objects, accompanied by longer fixation times and larger fixation amounts on these objects. Contrasting this, fixation towards the committee faces showed the reversed pattern; here, control participants exhibited longer fixations. Fixation indices and memory measures were, however, not correlated with each other. Psychosocial stress is associated with altered fixation behaviour. Longer fixation on objects related to the stressful situation may reflect enhanced encoding, whereas diminished face fixation suggests gaze avoidance of aversive, socially threatening stimuli. Modified visual exploration should be considered in future stress research, in particular when focussing on memory for a

  17. Overcoming fixation with repeated memory suppression.

    Science.gov (United States)

    Angello, Genna; Storm, Benjamin C; Smith, Steven M

    2015-01-01

    Fixation (blocks to memories or ideas) can be alleviated not only by encouraging productive work towards a solution, but, as the present experiments show, by reducing counterproductive work. Two experiments examined relief from fixation in a word-fragment completion task. Blockers, orthographically similar negative primes (e.g., ANALOGY), blocked solutions to word fragments (e.g., A_L_ _GY) in both experiments. After priming, but before the fragment completion test, participants repeatedly suppressed half of the blockers using the Think/No-Think paradigm, which results in memory inhibition. Inhibiting blockers did not alleviate fixation in Experiment 1 when conscious recollection of negative primes was not encouraged on the fragment completion test. In Experiment 2, however, when participants were encouraged to remember negative primes at fragment completion, relief from fixation was observed. Repeated suppression may nullify fixation effects, and promote creative thinking, particularly when fixation is caused by conscious recollection of counterproductive information.

  18. Eighth international congress on nitrogen fixation. Final program

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-31

    This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.

  19. K-wire and tension band wire fixation in treating sternoclavicular joint dislocation.

    Science.gov (United States)

    Chen, Qing-yu; Cheng, Shao-wen; Wang, Wei; Lin, Zhong-qin; Zhang, Wei; Kou, Dong-quan; Shen, Yue; Ying, Xiao-zhou; Cheng, Xiao-jie; Lv, Chuan-zhu; Peng, Lei

    2011-02-01

    To evaluate the feasibility and therapeutic effect of treating sternoclavicular joint dislocation by K-wire and tension band wire fixation, and to improve the safety and stability of this technique. This study consisted of 9 cases, 6 males and 3 females with the mean age of 25 years (range, 9-62 years). The causes were traffic accident in 7 cases, falling in 1 case and fight in 1 case. The duration from injury to operation was 2 hours to 7 days. There were 5 left dislocations and 4 right dislocations; 8 anterior dislocations and 1 posterior dislocation, including one combined with left scapular fracture and one with left olecranon fracture. Open reduction and internal fixation using K-wires and tension band wires were performed to treat dislocations. All patients were followed up for 6 to 24 months, 10 months on average. According to Rockwood's rating scale on postoperative sternoclavicular joint, 8 cases achieved excellent outcomes with an average score of 13.88, and the rest case achieved a good outcome with the score of 12. Anatomical reduction was obtained in all cases. There were no such postoperative complications as severe infection, injury to blood vessel and nerve, failure of fixation, etc. Patients were all satisfied with the anatomical reduction and functional recovery. The technique of K-wire and tension band wire fixation is safe, simple, effective, less invasive and has been successfully used in orthopedic surgery. It is effective in treating sternoclavicular joint dislocation though it has some disadvantages.

  20. Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure

    Directory of Open Access Journals (Sweden)

    Sanjoy Roy

    2015-01-01

    Full Text Available Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAPTM Open and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p<0.00001. Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p<0.001. Scores in five of the six sources of stress were significantly lower for mechanical fixation. Conclusions. Mechanical fixation with ETHICON SECURESTRAPTM Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure.

  1. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    Science.gov (United States)

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  2. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures

    Directory of Open Access Journals (Sweden)

    Rajasekhar Gali

    2016-01-01

    Full Text Available Introduction: Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. Purpose: This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. Patients and Methods: This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a the ease of access for retrieval, reimplantation and fixation of the proximal segment; b the postoperative approach related complications; c the adequacy of anatomical reduction and stability of fixation; d the occlusal changes; and the e TMJ function and radiological changes. Results: Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. Conclusion: The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby

  3. Preauricular transmasseteric anteroparotid approach for extracorporeal fixation of mandibular condyle fractures.

    Science.gov (United States)

    Gali, Rajasekhar; Devireddy, Sathya Kumar; Venkata, Kishore Kumar Rayadurgam; Kanubaddy, Sridhar Reddy; Nemaly, Chaithanyaa; Dasari, Mallikarjuna

    2016-01-01

    Free grafting or extracorporeal fixation of traumatically displaced mandibular condyles is sometimes required in patients with severe anteromedial displacement of condylar head. Majority of the published studies report the use of a submandibular, retromandibular or preauricular incisions for the access which have demerits of limited visibility, access and potential to cause damage to facial nerve and other parotid gland related complications. This retrospective clinical case record study was done to evaluate the preauricular transmasseteric anteroparotid (P-TMAP) approach for open reduction and extracorporeal fixation of displaced and dislocated high condylar fractures of the mandible. This retrospective study involved search of clinical case records of seven patients with displaced and dislocated high condylar fractures treated by open reduction and extracorporeal fixation over a 3-year period. The parameters assessed were as follows: a) the ease of access for retrieval, reimplantation and fixation of the proximal segment; b) the postoperative approach related complications; c) the adequacy of anatomical reduction and stability of fixation; d) the occlusal changes; and the e) TMJ function and radiological changes. Accessibility and visibility were good. Accurate anatomical reduction and fixation were achieved in all the patients. The recorded complications were minimal and transient. Facial nerve (buccal branch) palsy was noted in one patient with spontaneous resolution within 3 months. No cases of sialocele or Frey's syndrome were seen. The P-TMAP approach provides good access for open reduction and extracorporeal fixation of severely displaced condylar fractures. It facilitates retrieval, transplantation, repositioning, fixing the condyle and also reduces the chances of requirement of a vertical ramus osteotomy. It gives straight-line access to condylar head and ramus thereby permitting perpendicular placement of screws with minimal risk of damage to the facial

  4. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  5. Dinitrogen fixation in aphotic oxygenated marine environments

    Directory of Open Access Journals (Sweden)

    Eyal eRahav

    2013-08-01

    Full Text Available We measured N2 fixation rates from oceanic zones that have traditionally been ignored as sources of biological N2 fixation; the aphotic, fully oxygenated, nitrate (NO3--rich, waters of the oligotrophic Levantine Basin (LB and the Gulf of Aqaba (GA. N2 fixation rates measured from pelagic aphotic waters to depths up to 720 m, during the mixed and stratified periods, ranged from 0.01 nmol N L-1 d-1 to 0.38 nmol N L-1 d-1. N2 fixation rates correlated significantly with bacterial productivity and heterotrophic diazotrophs were identified from aphotic as well as photic depths. Dissolved free amino acid amendments to whole water from the GA enhanced bacterial productivity by 2to 3.5 and N2 fixation rates by ~ 2 fold in samples collected from aphotic depths while in amendments to water from photic depths bacterial productivity increased 2 to 6 fold while N2 fixation rates increased by a factor of 2 to 4 illustrating that both BP an heterotrophic N2 fixation are carbon limited. Experimental manipulations of aphotic waters from the LB demonstrated a significant positive correlation between transparent exopolymeric particles (TEP concentration and N2 fixation rates. This suggests that sinking organic material and high carbon (C: nitrogen (N micro-environments (such as TEP-based aggregates or marine snow could support high heterotrophic N2 fixation rates in oxygenated surface waters and in the aphotic zones. Indeed, our calculations show that aphotic N2 fixation accounted for 37 to 75 % of the total daily integrated N2 fixation rates at both locations in the Mediterranean and Red Seas with rates equal or greater to those measured from the photic layers. Moreover, our results indicate that that while N2 fixation may be limited in the surface waters, aphotic, pelagic N2 fixation may contribute significantly to new N inputs in other oligotrophic basins, yet it is currently not included in regional or global N budgets.

  6. [Effectiveness comparison of flexible fixation and rigid fixation in treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis].

    Science.gov (United States)

    Li, Yuewei; Zhang, Minghui; Li, Xiaorong; Chen, Xiaoyong; Deng, Jianlong

    2017-07-01

    To compare the effectiveness of flexible fixation and rigid fixation in the treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis. A retrospective analysis was made on the clinical data of 50 patients with ankle pronation-external rotation fractures and distal tibiofibular syndesmosis treated between January 2013 and December 2015. Suture-button fixation was used in 23 patients (flexible fixation group) and cortical screw fixation in 27 patients (rigid fixation group). There was no significant difference in age, gender, weight, side, fracture type, and time from trauma to surgery between 2 groups ( P >0.05). The operation time, medial clear space (MCS), tibiofibular clear space (TFCS), tibiofibular overlap (TFO), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Foot and Ankle Disability Index (FADI) score were compared between 2 groups. The operation time was (83.0±9.1) minutes in the flexible fixation group and was (79.6±13.1) minutes in the rigid fixation group, showing no significant difference ( t =1.052, P =0.265). All patients achieved healing of incision by first intention. The patients were followed up 12-20 months (mean, 14 months). The X-ray films showed good healing of fracture in 2 groups. There was no screw fracture, delayed union or nounion. The fracture healing time was (12.1±2.5) months in the flexible fixation group and was (11.3±3.2) months in the rigid fixation group, showing no significant difference between 2 groups ( t =1.024, P =0.192). Reduction loss occurred after removal of screw in 2 cases of the rigid fixation group. At last follow-up, there was no significant difference in MCS, TFCS, TFO, AOFAS score and FADI score between 2 groups ( P >0.05). Suture-button fixation has similar effectiveness to screw fixation in ankle function and imaging findings, and flexible fixation has lower risk of reduction loss of distal tibiofibular syndesmosis than rigid fixation.

  7. Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?

    LENUS (Irish Health Repository)

    Nassiri, M

    2013-03-01

    The Locking Compression Plate (LCP) is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. Knowledge of the fixation stability provided by these new plates is very limited and clarification is still necessary to determine how the mechanical stability and the risk of implant failure can best be controlled.

  8. External fixation of femoral defects in athymic rats: Applications for human stem cell implantation and bone regeneration

    Directory of Open Access Journals (Sweden)

    Terasa Foo

    2013-01-01

    Full Text Available An appropriate animal model is critical for the research of stem/progenitor cell therapy and tissue engineering for bone regeneration in vivo. This study reports the design of an external fixator and its application to critical-sized femoral defects in athymic rats. The external fixator consists of clamps and screws that are readily available from hardware stores as well as Kirschner wires. A total of 35 rats underwent application of the external fixator with creation of a 6-mm bone defect in one femur of each animal. This model had been used in several separate studies, including implantation of collagen gel, umbilical cord blood mesenchymal stem cells, endothelial progenitor cells, or bone morphogenetic protein-2. One rat developed fracture at the proximal pin site and two rats developed deep tissue infection. Pin loosening was found in nine rats, but it only led to the failure of external fixation in two animals. In 8 to 10 weeks, various degrees of bone growth in the femoral defects were observed in different study groups, from full repair of the bone defect with bone morphogenetic protein-2 implantation to fibrous nonunion with collagen gel implantation. The external fixator used in these studies provided sufficient mechanical stability to the bone defects and had a comparable complication rate in athymic rats as in immunocompetent rats. The external fixator does not interfere with the natural environment of a bone defect. This model is particularly valuable for investigation of osteogenesis of human stem/progenitor cells in vivo.

  9. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    Science.gov (United States)

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve

  10. Tropical Dominance of N2 Fixation in the North Atlantic Ocean

    Science.gov (United States)

    Marconi, Dario; Sigman, Daniel M.; Casciotti, Karen L.; Campbell, Ethan C.; Alexandra Weigand, M.; Fawcett, Sarah E.; Knapp, Angela N.; Rafter, Patrick A.; Ward, Bess B.; Haug, Gerald H.

    2017-10-01

    To investigate the controls on N2 fixation and the role of the Atlantic in the global ocean's fixed nitrogen (N) budget, Atlantic N2 fixation is calculated by combining meridional nitrate fluxes across World Ocean Circulation Experiment sections with observed nitrate 15N/14N differences between northward and southward transported nitrate. N2 fixation inputs of 27.1 ± 4.3 Tg N/yr and 3.0 ± 0.5 Tg N/yr are estimated north of 11°S and 24°N, respectively. That is, 90% of the N2 fixation in the Atlantic north of 11°S occurs south of 24°N in a region with upwelling that imports phosphorus (P) in excess of N relative to phytoplankton requirements. This suggests that, under the modern iron-rich conditions of the equatorial and North Atlantic, N2 fixation occurs predominantly in response to P-bearing, N-poor conditions. We estimate a N2 fixation rate of 30.5 ± 4.9 Tg N/yr north of 30°S, implying only 3 Tg N/yr between 30° and 11°S, despite evidence of P-bearing, N-poor surface waters in this region as well; this is consistent with iron limitation of N2 fixation in the South Atlantic. Since the ocean flows through the Atlantic surface in Pacific basins.

  11. Strain-stress analysis of lower limb with applied fixator

    Directory of Open Access Journals (Sweden)

    Mrázek M.

    2010-07-01

    Full Text Available This paper compares physiological state of tibia before and after application of an external fixator. The fixator systems’ models but also model of tibia are loaded in the direction of body axis. The paper is focused on the examination of differences in stiffness before and after the application of fixation. Two types of axial external fixators are compared. Both fixators differ in their construction. The first fixator is two-frame and fixation rods are used for fixing the bone tissue (variant I. The second one is fixed into tibia with screws (variant II. We have found out that the two-frame external fixator has much bigger stiffness during limb fixation than the fixator with one body. Much higher deformations compared to physiological state of tibia occur in the variant II.

  12. Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins.

    Science.gov (United States)

    Christie, J; Howie, C R; Armour, P C

    1988-03-01

    One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.

  13. Early Conversion of External Fixation to Interlocked Nailing in Open Fractures of Both Bone Leg Assisted with Vacuum Closure (VAC) - Final Outcome.

    Science.gov (United States)

    Gill, Simrat Pal Singh; Raj, Manish; Kumar, Sunil; Singh, Pulkesh; Kumar, Dinesh; Singh, Jasveer; Deep, Akash

    2016-02-01

    Management of compound grade III fractures of both bone leg includes external stabilization for long period, followed by various soft tissue coverage procedures. Primary interlocking of tibia had been also done with variable results. External fixation for long time without any bone loss often leads to infected nonunion, loss of reduction, pin tract infection and failure of fixation, primary interlocking in compound grade III fractures had shown high medullary infection rate. We managed all cases of compound grade III A/B fractures with primary external fixation, simultaneous wound management using vacuum assisted closure (VAC) followed by early conversion to interlocking within 2 weeks of fixator application. To determine the effectiveness of vacuum assisted closure (VAC) for the early conversion of external fixator to definitive interlocking in open fractures of the both bone leg. In current study we selected 84 cases of compound grade IIIA/B diaphyseal fractures of both bone leg during period of May 2010 to September 2013. We managed these cases by immediate debridement and application of external fixation followed by repeated debridement, application of vacuum assisted closure (VAC) and conversion to interlocking within two weeks. Out of 84 cases union was achieved in 80(95%) of cases with definitive tibial interlocking. Excellent to good result were obtained in 77(91.8%) of cases and fair to poor result seen in rest of 7(8.2%) of cases according to modified Ketenjian's criteria. 5 out of these 7 poor result group cases were from Compound Grade III B group to start with. Deep infection rate in our series were 7% i.e. total 6 cases and 4 out of these were from compound Grade III B group to start with. Vacuum assisted closure (VAC) give a good help for rapid closure of the wound and help in early conversion to definitive intramedullary nailing. Reamed nail could well be used in compound grade IIIA/B fractures without increasing the risk of infection. It gives

  14. Use of 15N dilution method for screening soybean lines with high yield and high nitrogen fixation ability

    International Nuclear Information System (INIS)

    Li Haixian; Li Xinmin; Danso, S.K.A.

    1998-01-01

    15 N dilution method was used for screening soybean lines with high nitrogen fixation ability. Screened lines 1005, 8502, 2096, 943, 1454 and Dongnong-42 have high nitrogen fixation ability with their % Ndfa of about 70%. 1454 and 1555 are both high yield and high nitrogen fixation lines. The ability of nitrogen fixation was not related to the yield, but related to maturing time. The cultivars with different maturing time have different levels of nitrogen fixation ability. The longer the maturing period is, the greater the ability of nitrogen fixation it has. There were ten cultivars or lines used in the test of 1992 and 1994. Although the weather condition were greatly different between the two years the results of seven cultivars or lines were the same, indicating that nitrogen fixation ability of the soybean is stable with years. Using 15 N dilution method to estimate nitrogen fixation ability of soybean is reliable, however, the % Ndfa of lines 8502 and 2096 increased by 19% in 1994, a rainy year, indicating that a change in % Ndfa with a few varieties maybe caused by weather

  15. Oscillatory brain dynamics during sentence reading: A Fixation-related spectral perturbation analysis.

    Directory of Open Access Journals (Sweden)

    Lorenzo eVignali

    2016-04-01

    Full Text Available The present study investigated oscillatory brain dynamics during self-paced sentence-level processing. Participants read fully correct sentences, sentences containing a semantic violation and sentences in which the order of the words was randomized. At the target word level, fixations on semantically unrelated words elicited a lower-beta band (13-18 Hz desynchronization. At the sentence level, gamma power (31-55 Hz increased linearly for syntactically correct sentences, but not when the order of the words was randomized. In the 300 to 900 ms time window after sentence onsets, theta power (4-7 Hz was greater for syntactically correct sentences as compared to sentences where no syntactic structure was preserved (random words condition. We interpret our results as conforming with a recently formulated predictive-coding framework for oscillatory neural dynamics during sentence-level language comprehension. Additionally, we discuss how our results relate to previous findings with serial visual presentation versus self-paced reading.

  16. N2 production and fixation in deep-tier burrows of Squilla empusa in muddy sediments of Great Peconic Bay

    Science.gov (United States)

    Waugh, Stuart; Aller, Robert C.

    2017-11-01

    Global marine N budgets often show deficits due to dominance of benthic N2 production relative to pelagic N2 fixation. Recent studies have argued that benthic N2 fixation in shallow water environments has been underestimated. In particular, N2 fixation associated with animal burrows may be significant as indicated by high rates of N2 fixation reported in muddy sands populated by the ghost shrimp, Neotrypaea californiensis (Bertics et al., 2010). We investigated whether N2 fixation occurs at higher rates in the burrow-walls of the deep-burrowing ( 0.5-4 m) mantis shrimp, Squilla empusa, compared to ambient, estuarine muds and measured seasonal in-situ N2 concentrations in burrow-water relative to bottom-water. Acetylene reduction assays showed lower N2 fixation in burrow-walls than in un-populated sediments, likely due to inhibitory effects of O2 on ethylene production. Dissolved N2 was higher in burrow-water than proximate bottom-water at all seasons, demonstrating a consistent balance of net N2 production relative to fixation in deep-tier biogenic structures.

  17. Distal tibial fracture treated by minimally invasive plate osteosynthesis after external fixation Retrospective clinical and radiographic assessment

    Directory of Open Access Journals (Sweden)

    Al. Șerban

    2014-02-01

    Full Text Available Fractures of the horizontal surface of the distal tibia are known commonly as pylon or plafond fractures, and represent 1-5% of lower extremity fractures, 7-10% of all tibial fractures. The protocol consisted of immediate (within eight to 24 hours open reduction and internal fixation of the fibula, using a fibular plate or one third tubular plate and application of an external fixator spanning the ankle joint. In the second stage, the treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can preserve soft tissue, simplify operative procedure and decrease wound, obtain rigid internal fixation and guarantee early function exercises of ankle joint. In this study we evaluated 22 patients treated in Clinical Emergency Hospital Constanta between April 2012 - July 2013 diagnosed with multifragmentary fractures of the distal tibia. This study evaluates the treatment of complex fractures of distal tibia with locked plate after external fixation. There were 17 males and 5 females of mean age 51,7 years (31-68. The mean follow-up period was 14 weeks. (Ranging from 9-16 weeks. All patients were fully weight bearing at 16 weeks (ranging 9-16 weeks showing radiological union. There were no cases of failures of fixation, or rotational misalignment. No significant complication was observed in our patients. MIPO is an effective method of treatment for distal tibial fractures, reduce surgical trauma and maintain a more biologically favorable environment for fracture healing, reducing risks of infection and nonunion.

  18. Wiring Techniques for the Fixation of Trochanteric Fragments during Bipolar Hemiarthroplasty for Femoral Intertrochanteric Fracture: Clinical Study and Technical Note.

    Science.gov (United States)

    Lee, Joong-Myung; Cho, Yongsuk; Kim, Junhyun; Kim, Dong-Won

    2017-03-01

    Femoral intertrochanteric fractures are common in the elderly. Appropriate surgical fixation of trochanteric fracture fragments can restore normal anatomical structure and ambulation, and can aid in the recovery of biomechanical function of the hip. We evaluated clinical outcomes of bipolar hemiarthroplasty using a wiring technique for trochanteric fracture fragment fixation. From September 2006 to February 2015, a total of 260 cases underwent simultaneous bipolar hemiarthroplasty and wire fixation. A total of 65 patients (69 hips) with an average age of 78 years and more than one year of follow-up was included in the study. Using pre-, postoperative and follow-up radiograms, we evaluated wire fixation failure and also assessed changes in walking ability. Loosening or osteolysis around the stem was not observed; however, we did observe bone growth around the stem (54 cases), cortical hypertrophy (6 cases), a wide range of sclerotic lines but no stem subsidence (1 case), wire breakage (9 cases), and fracture fragment migration with no significant functional deficiency (2 cases). Our study showed that additional wiring for trochanteric fracture fragment fixation following bipolar hemiarthroplasty can help restore normal anatomy. The added stability results in faster rehabilitation, and good clinical and radiographic outcomes. We recommend this procedure in this type of fracture.

  19. Flexible fixation and fracture healing

    DEFF Research Database (Denmark)

    Schmal, Hagen; Strohm, Peter C; Jaeger, Martin

    2011-01-01

    , noncomminuted fractures. External fixation uses external bars for stabilization, whereas internal fixation is realized by subcutaneous placement of locking plates. Both of these "biologic" osteosynthesis methods allow a minimally invasive approach and do not compromise fracture hematoma and periosteal blood...

  20. Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study.

    Science.gov (United States)

    Sobhan, Mohammad R; Abrisham, Seyed Mohammad J; Vakili, Mahmood; Shirdel, Saeed

    2016-10-01

    Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient's quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations. Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT) scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed's score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described. The injury was unilateral in 11 (78.5%) patients and bilateral in 3 (21.5%). Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4%) and 1 (7.1%) cases, respectively. In this study most patients (85%) return to work postoperatively. According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.

  1. Chasing red herrings: Memory of distractors causes fixation in creative problem solving.

    Science.gov (United States)

    Beda, Zsolt; Smith, Steven M

    2018-03-07

    Two experiments tested the red herring retrieval hypothesis, which states that fixation in creative problem solving is worse when memory for red herrings (i.e., inappropriate or incorrect solutions) is strengthened. In Experiment 1, when associations between Remote Associates Test (RAT) problem words (e.g., COTTAGE, SWISS, CAKE) and related red herring words (e.g., hut, chocolate, icing) were strengthened via repetition, an encoding variable, fixation was found to increase. In Experiment 2, when associations were formed between RAT problem contexts and red herrings, then subsequent reinstatement of problem contexts during RAT problem solving trials (as compared with showing new contexts) also worsened fixation effects. Our results add to the increasing body of research that connects memory with creative problem solving, and they suggest possible ways for overcoming fixation effects.

  2. On experiments to detect possible failures on relativity theory

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1982-01-01

    Conditions under which is expected the failure of Einstein's Relativity are analysed. A complete analysis of a recently proposed experiment by Kolen-Torr is also given showing that it must give a negative result. (Author) [pt

  3. Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability.

    Science.gov (United States)

    Işik, Hasan Serdar; Sandal, Evren; Çağli, Sedat

    2017-06-14

    In this study, we aimed at sharing our experiences and contributing to the literature by making a retrospective analysis of the patients we operated with screw-rod system for atlantoaxial instability in our clinic. Archive files of adult patients, who were operated for posterior C1-C2 stabilization with screw and rod in our clinic between January 2006 and January 2016, were analyzed. 28 patients, who had pre and post-operative images, follow-up forms and who were followed for at least one year, were analyzed. Preoperative clinical and radiological records, preoperative observations, postoperative complications, and clinical responses were evaluated. The average age of 28 patients (F:13 M:19) was 44.7 (21-73). Fixation was performed with C1-C2 screw-rod system on the basis of the following diagnoses; type 2 odontoid fracture (16), basilar invagination (5), C1-C2 instability (5), and atlantoaxial subluxation secondary to rheumatoid arthritis (2). Lateral mass screws were inserted at C1 segment. C2 screws inserted were bilateral pedicle in 12 cases, bilateral pars in 4, bilateral laminar in 8 and one side pars, one side laminar in 4 cases. There was no screw malposition. Neither implant failure nor recurrent instability was observed during follow-up. Significant clinical improvement was reported according to the assessments done with JOA and VAS scores. C1-C2 screw fixation is regarded as a more successful and safe method than other fixation methods in surgical treatment of atlantoaxial instability considering complications, success in reduction, fusion and fixation strength. C2 laminar screw technique is as successful as the other alternatives in fixation and fusion.

  4. Transpedicular fixation for the espondilolistesis treatment, espondilolisis and channel lumbar narrow of the lumbosacral column

    International Nuclear Information System (INIS)

    Matta Javier Ernesto; Diaz, Cesar Jacobo; Gamba S, Cesar Enrique

    2002-01-01

    A descriptive, prospective study was designs with the objective of analyzing the experience with the technique of transpedicular fixation, for the treatment of degenerative espondilolistesis, espondilolisis and channel lumbar narrow. Eighty patients (42 men and 38 women) they were intervened between February of 1992 and February of 2002; the age average was of 46,3 years and the minimum pursuit of 7 months. The cases were tabulated according to the diagnostic, clinical presentation, previous interventions, descompressive procedures associated to the fixation, anatomical level of lesion, number of fixed vertebras, number of placed screws, type of bony implants and complications. In 33 patients (41,3%) it diagnose degenerative espondilolistesis, espondilolisis in 24 (30%), channel lumbar narrow in 20 (25%), displasic espondilolistesis in 2,5% and espondiloptosis in 1%. the clinical presentations more frequent were radicular and lumbar pain, with 33,8 each one; one carries out arthrodesis 15-S1 in 38 patients (47,5%) and 14 15 in 15 patients (18,7%). as complications we find deep infection in 7,5% of the cases, neurological deficit in 5%, rupture of duramadre 3,8%, false route of screws, bony failure and material rupture in 2,5% each one and seroma in 1,3%. Doesn't present seudoarthrosis. The transpedicular fixation is a sure technique for the treatment of the degenerative espondilolistesis, espondilolisis and channel lumbar narrow. With the transpedicular fixation the average of fixed vertebras is smaller than with the Harrington and Luque techniques, preserving in more degree the mobility to articulate. The association of the transpedicular fixation with arthrodesis and coalition by means of placement of autogenous implants diminishes the seudoarthrosis incidence

  5. Comparative sequence analysis of nitrogen fixation-related genes in six legumes

    Directory of Open Access Journals (Sweden)

    Dong Hyun eKim

    2013-08-01

    Full Text Available Legumes play an important role as food and forage crops in international agriculture especially in developing countries. Legumes have a unique biological process called nitrogen fixation (NF by which they convert atmospheric nitrogen to ammonia. Although legume genomes have undergone polyploidization, duplication and divergence, NF-related genes, because of their essential functional role for legumes, might have remained conserved. To understand the relationship of divergence and evolutionary processes in legumes, this study analyzes orthologs and paralogs for selected 20 NF-related genes by using comparative genomic approaches in six legumes i.e. Medicago truncatula (Mt, Cicer arietinum, Lotus japonicus, Cajanus cajan (Cc, Phaseolus vulgaris (Pv and Glycine max (Gm. Subsequently, sequence distances, numbers of synonymous substitutions per synonymous site (Ks and nonsynonymous substitutions per nonsynonymous site (Ka between orthologs and paralogs were calculated and compared across legumes. These analyses suggest the closest relationship between Gm and Cc and the farthest distance between Mt and Pv in 6 legumes. Ks proportional plots clearly showed ancient genome duplication in all legumes, whole genome duplication event in Gm and also speciation pattern in different legumes. This study also reported some interesting observations e.g. no peak at Ks 0.4 in Gm-Gm, location of two independent genes next to each other in Mt and low Ks values for outparalogs for three genes as compared to other 12 genes. In summary, this study underlines the importance of NF-related genes and provides important insights in genome organization and evolutionary aspects of six legume species analyzed.

  6. Customizable rigid head fixation for infants: technical note.

    Science.gov (United States)

    Udayakumaran, Suhas; Onyia, Chiazor U

    2016-01-01

    The need and advantages of rigid fixation of the head in cranial surgeries are well documented (Berryhill et al., Otolaryngol Head Neck Surg 121:269-273, 1999). Head fixation for neurosurgical procedures in infants and in early years has been a challenge and is fraught with risk. Despite the fact that pediatric pins are designed, rigid head fixation involving direct application of pins to the head of infants and slightly older children is still generally not safe (Agrawal and Steinbok, Childs Nerv Syst 22:1473-1474, 2006). Yet, there are some surgeries in which some form of rigid fixation is required (Agrawal and Steinbok, Childs Nerv Syst 22:1473-1474, 2006). We describe a simple technique to achieve rigid fixation of the head in infants for neurosurgical procedures. This involves applying a head band made of Plaster of Paris (POP) around the head and then applying the fixation pins of the fixation frame directly on to the POP. We have used this technique of head fixation successfully for infants with no complications.

  7. Features of Recent Codon Evolution: A Comparative Polymorphism-Fixation Study

    Directory of Open Access Journals (Sweden)

    Zhongming Zhao

    2010-01-01

    Full Text Available Features of amino-acid and codon changes can provide us important insights on protein evolution. So far, investigators have often examined mutation patterns at either interspecies fixed substitution or intraspecies nucleotide polymorphism level, but not both. Here, we performed a unique analysis of a combined set of intra-species polymorphisms and inter-species substitutions in human codons. Strong difference in mutational pattern was found at codon positions 1, 2, and 3 between the polymorphism and fixation data. Fixation had strong bias towards increasing the rarest codons but decreasing the most frequently used codons, suggesting that codon equilibrium has not been reached yet. We detected strong CpG effect on CG-containing codons and subsequent suppression by fixation. Finally, we detected the signature of purifying selection against A∣U dinucleotides at synonymous dicodon boundaries. Overall, fixation process could effectively and quickly correct the volatile changes introduced by polymorphisms so that codon changes could be gradual and directional and that codon composition could be kept relatively stable during evolution.

  8. The emergence and early evolution of biological carbon-fixation.

    Science.gov (United States)

    Braakman, Rogier; Smith, Eric

    2012-01-01

    The fixation of CO₂ into living matter sustains all life on Earth, and embeds the biosphere within geochemistry. The six known chemical pathways used by extant organisms for this function are recognized to have overlaps, but their evolution is incompletely understood. Here we reconstruct the complete early evolutionary history of biological carbon-fixation, relating all modern pathways to a single ancestral form. We find that innovations in carbon-fixation were the foundation for most major early divergences in the tree of life. These findings are based on a novel method that fully integrates metabolic and phylogenetic constraints. Comparing gene-profiles across the metabolic cores of deep-branching organisms and requiring that they are capable of synthesizing all their biomass components leads to the surprising conclusion that the most common form for deep-branching autotrophic carbon-fixation combines two disconnected sub-networks, each supplying carbon to distinct biomass components. One of these is a linear folate-based pathway of CO₂ reduction previously only recognized as a fixation route in the complete Wood-Ljungdahl pathway, but which more generally may exclude the final step of synthesizing acetyl-CoA. Using metabolic constraints we then reconstruct a "phylometabolic" tree with a high degree of parsimony that traces the evolution of complete carbon-fixation pathways, and has a clear structure down to the root. This tree requires few instances of lateral gene transfer or convergence, and instead suggests a simple evolutionary dynamic in which all divergences have primary environmental causes. Energy optimization and oxygen toxicity are the two strongest forces of selection. The root of this tree combines the reductive citric acid cycle and the Wood-Ljungdahl pathway into a single connected network. This linked network lacks the selective optimization of modern fixation pathways but its redundancy leads to a more robust topology, making it more

  9. The emergence and early evolution of biological carbon-fixation.

    Directory of Open Access Journals (Sweden)

    Rogier Braakman

    Full Text Available The fixation of CO₂ into living matter sustains all life on Earth, and embeds the biosphere within geochemistry. The six known chemical pathways used by extant organisms for this function are recognized to have overlaps, but their evolution is incompletely understood. Here we reconstruct the complete early evolutionary history of biological carbon-fixation, relating all modern pathways to a single ancestral form. We find that innovations in carbon-fixation were the foundation for most major early divergences in the tree of life. These findings are based on a novel method that fully integrates metabolic and phylogenetic constraints. Comparing gene-profiles across the metabolic cores of deep-branching organisms and requiring that they are capable of synthesizing all their biomass components leads to the surprising conclusion that the most common form for deep-branching autotrophic carbon-fixation combines two disconnected sub-networks, each supplying carbon to distinct biomass components. One of these is a linear folate-based pathway of CO₂ reduction previously only recognized as a fixation route in the complete Wood-Ljungdahl pathway, but which more generally may exclude the final step of synthesizing acetyl-CoA. Using metabolic constraints we then reconstruct a "phylometabolic" tree with a high degree of parsimony that traces the evolution of complete carbon-fixation pathways, and has a clear structure down to the root. This tree requires few instances of lateral gene transfer or convergence, and instead suggests a simple evolutionary dynamic in which all divergences have primary environmental causes. Energy optimization and oxygen toxicity are the two strongest forces of selection. The root of this tree combines the reductive citric acid cycle and the Wood-Ljungdahl pathway into a single connected network. This linked network lacks the selective optimization of modern fixation pathways but its redundancy leads to a more robust topology

  10. Use of low enriched 15N2 for symbiotic fixation tests

    International Nuclear Information System (INIS)

    Victoria, R.L.

    1975-01-01

    Gaseous atmospheres containing 15 N 2 with low enrichment were used to test symbiotic nitrogen fixation in beans (Phaseolus vulgari, L.). The tests of fixation in nodulated roots and the tests of fixation in the whole plant, in which the plants were placed inside a specially constructed growth chamber, gave positive results and suggest that the methodology used can be very helpfull in more detailed studies on symbiotic fixation. Samples of atmospheric air were purified by absorption of O 2 and CO 2 by two methods. The purified N 2 obtained was analysed and the results were compared. Samples of bean plant material were collected in natural conditions and analysed for 15 N natural variation. Several samples were prepared for 15 N isotopic analysis by two methods. The results obtained were compared. All samples were analysed in an Atlas-Varian Ch-4 model mass spectrometer, and the results were given in delta 15 N 0 / 00 variation in relation to a standard gas

  11. Fixation probability on clique-based graphs

    Science.gov (United States)

    Choi, Jeong-Ok; Yu, Unjong

    2018-02-01

    The fixation probability of a mutant in the evolutionary dynamics of Moran process is calculated by the Monte-Carlo method on a few families of clique-based graphs. It is shown that the complete suppression of fixation can be realized with the generalized clique-wheel graph in the limit of small wheel-clique ratio and infinite size. The family of clique-star is an amplifier, and clique-arms graph changes from amplifier to suppressor as the fitness of the mutant increases. We demonstrate that the overall structure of a graph can be more important to determine the fixation probability than the degree or the heat heterogeneity. The dependence of the fixation probability on the position of the first mutant is discussed.

  12. Do Bone Graft and Cracking of the Sclerotic Cavity Improve Fixation of Titanium and Hydroxyapatite-coated Revision Implants in an Animal Model?

    Science.gov (United States)

    Elmengaard, Brian; Baas, Joergen; Jakobsen, Thomas; Kold, Soren; Jensen, Thomas B; Bechtold, Joan E; Soballe, Kjeld

    2017-02-01

    We previously introduced a manual surgical technique that makes small perforations (cracks) through the sclerotic bone shell that typically forms during the process of aseptic loosening ("crack" revision technique). Perforating just the shell (without violating the proximal cortex) can maintain overall bone continuity while allowing marrow and vascular elements to access the implant surface. Because many revisions require bone graft to fill defects, we wanted to determine if bone graft could further increase implant fixation beyond what we have experimentally shown with the crack technique alone. Also, because both titanium (Ti6Al4V) and hydroxyapatite (HA) implant surfaces are used in revisions, we also wanted to determine their relative effectiveness in this model. We hypothesized that both (1) allografted plasma-sprayed Ti6Al4V; and (2) allografted plasma-sprayed HA-coated implants inserted with a crack revision technique have better fixation compared with a noncrack revision technique in each case. Under approval from our Institutional Animal Care and Use Committee, a female canine animal model was used to evaluate the uncemented revision technique (crack, noncrack) using paired contralateral implants while implant surface (Ti6Al4V, HA) was qualitatively compared between the two (unpaired) series. All groups received bone allograft tightly packed around the implant. This revision model includes a cylindrical implant pistoning 500 μm in a 0.75-mm gap, with polyethylene particles, for 8 weeks. This engenders a bone and tissue response representative of the metaphyseal cancellous region of an aseptically loosened component. At 8 weeks, the original implants were revised and followed for an additional 4 weeks. Mechanical fixation was assessed by load, stiffness, and energy to failure when loaded in axial pushout. Histomorphometry was used to determine the amount and location of bone and fibrous tissue in the grafted gap. The grafted crack revision improved

  13. Immaturity of Visual Fixations in Dyslexic Children.

    Directory of Open Access Journals (Sweden)

    TIADI eBi Kuyami Guy Aimé

    2016-02-01

    Full Text Available To our knowledge, behavioral studies recording visual fixations abilities in dyslexic children are scarce. The object of this paper is to explore further the visual fixation ability in dyslexics compared to chronological age-matched and reading age-matched non-dyslexic children. Fifty-five dyslexic children from 7 to 14 years old, fifty-five chronological age-matched non-dyslexic children and fifty-five reading age-matched non-dyslexic children participated to this study. Eye movements from both eyes were recorded horizontally and vertically by a video-oculography system (EyeBrain® T2. The fixation task consisted in fixating a white-filled circle appearing in the centre of the screen for 30 seconds. Results showed that dyslexic children produced a significantly higher number of unwanted saccades than both groups of non-dyslexic children. Moreover, the number of unwanted saccades significantly decreased with age in both groups of non-dyslexic children, but not in dyslexics. Furthermore, dyslexics made more saccades during the last 15 sec of fixation period with respect to both groups of non-dyslexic children. Such poor visual fixation capability in dyslexic children could be due to impaired attention abilities, as well as to an immaturity of the cortical areas controlling the fixation system.

  14. Statistical analysis of events related to emergency diesel generators failures in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Kančev, Duško, E-mail: dusko.kancev@ec.europa.eu [European Commission, DG-JRC, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Duchac, Alexander; Zerger, Benoit [European Commission, DG-JRC, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Maqua, Michael [Gesellschaft für Anlagen-und-Reaktorsicherheit (GRS) mbH, Schwetnergasse 1, 50667 Köln (Germany); Wattrelos, Didier [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), BP 17 - 92262 Fontenay-aux-Roses Cedex (France)

    2014-07-01

    Highlights: • Analysis of operating experience related to emergency diesel generators events at NPPs. • Four abundant operating experience databases screened. • Delineating important insights and conclusions based on the operating experience. - Abstract: This paper is aimed at studying the operating experience related to emergency diesel generators (EDGs) events at nuclear power plants collected from the past 20 years. Events related to EDGs failures and/or unavailability as well as all the supporting equipment are in the focus of the analysis. The selected operating experience was analyzed in detail in order to identify the type of failures, attributes that contributed to the failure, failure modes potential or real, discuss risk relevance, summarize important lessons learned, and provide recommendations. The study in this particular paper is tightly related to the performing of statistical analysis of the operating experience. For the purpose of this study EDG failure is defined as EDG failure to function on demand (i.e. fail to start, fail to run) or during testing, or an unavailability of an EDG, except of unavailability due to regular maintenance. The Gesellschaft für Anlagen und Reaktorsicherheit mbH (GRS) and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) databases as well as the operating experience contained in the IAEA/NEA International Reporting System for Operating Experience and the U.S. Licensee Event Reports were screened. The screening methodology applied for each of the four different databases is presented. Further on, analysis aimed at delineating the causes, root causes, contributing factors and consequences are performed. A statistical analysis was performed related to the chronology of events, types of failures, the operational circumstances of detection of the failure and the affected components/subsystems. The conclusions and results of the statistical analysis are discussed. The main findings concerning the testing

  15. Statistical analysis of events related to emergency diesel generators failures in the nuclear industry

    International Nuclear Information System (INIS)

    Kančev, Duško; Duchac, Alexander; Zerger, Benoit; Maqua, Michael; Wattrelos, Didier

    2014-01-01

    Highlights: • Analysis of operating experience related to emergency diesel generators events at NPPs. • Four abundant operating experience databases screened. • Delineating important insights and conclusions based on the operating experience. - Abstract: This paper is aimed at studying the operating experience related to emergency diesel generators (EDGs) events at nuclear power plants collected from the past 20 years. Events related to EDGs failures and/or unavailability as well as all the supporting equipment are in the focus of the analysis. The selected operating experience was analyzed in detail in order to identify the type of failures, attributes that contributed to the failure, failure modes potential or real, discuss risk relevance, summarize important lessons learned, and provide recommendations. The study in this particular paper is tightly related to the performing of statistical analysis of the operating experience. For the purpose of this study EDG failure is defined as EDG failure to function on demand (i.e. fail to start, fail to run) or during testing, or an unavailability of an EDG, except of unavailability due to regular maintenance. The Gesellschaft für Anlagen und Reaktorsicherheit mbH (GRS) and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) databases as well as the operating experience contained in the IAEA/NEA International Reporting System for Operating Experience and the U.S. Licensee Event Reports were screened. The screening methodology applied for each of the four different databases is presented. Further on, analysis aimed at delineating the causes, root causes, contributing factors and consequences are performed. A statistical analysis was performed related to the chronology of events, types of failures, the operational circumstances of detection of the failure and the affected components/subsystems. The conclusions and results of the statistical analysis are discussed. The main findings concerning the testing

  16. Graft fixation in cruciate ligament reconstruction.

    Science.gov (United States)

    Brand, J; Weiler, A; Caborn, D N; Brown, C H; Johnson, D L

    2000-01-01

    Cruciate ligament reconstruction has progressed dramatically in the last 20 years. Anatomic placement of ligament substitutes has fostered rehabilitation efforts that stress immediate and full range of motion, immediate weightbearing, neuromuscular strength and coordination, and early return to athletic competition (3 months). This has placed extreme importance on secure graft fixation at the time of ligament reconstruction. Current ligament substitutes require a bony or soft tissue component to be fixed within a bone tunnel or on the periosteum at a distance from the normal ligament attachment site. Fixation devices have progressed from metal to biodegradable and from far to near-normal native ligament attachment sites. Ideally, the biomechanical properties of the entire graft construct would approach those of the native ligament and facilitate biologic incorporation of the graft. Fixation should be done at the normal anatomic attachment site of the native ligament (aperture fixation) and, over time, allow the biologic return of the histologic transition zone from ligament to fibrocartilage, to calcified fibrocartilage, to bone. The purpose of this article is to review current fixation devices and techniques in cruciate ligament surgery.

  17. Benthic Dinitrogen Fixation Traversing the Oxygen Minimum Zone Off Mauritania (NW Africa

    Directory of Open Access Journals (Sweden)

    Jessica Gier

    2017-12-01

    Full Text Available Despite its potential to provide new nitrogen (N to the environment, knowledge on benthic dinitrogen (N2 fixation remains relatively sparse, and its contribution to the marine N budget is regarded as minor. Benthic N2 fixation is often observed in organic-rich sediments coupled to heterotrophic metabolisms, such as sulfate reduction. In the present study, benthic N2 fixation together with sulfate reduction and other heterotrophic metabolisms were investigated at six station between 47 and 1,108 m water depth along the 18°N transect traversing the highly productive upwelling region known as Mauritanian oxygen minimum zone (OMZ. Bottom water oxygen concentrations ranged between 30 and 138 μM. Benthic N2 fixation determined by the acetylene reduction assay was detected at all stations with highest rates (0.15 mmol m−2 d−1 on the shelf (47 and 90 m water depth and lowest rates (0.08 mmol m−2 d−1 below 412 m water depth. The biogeochemical data suggest that part of the N2 fixation could be linked to sulfate- and iron-reducing bacteria. Molecular analysis of the key functional marker gene for N2 fixation, nifH, confirmed the presence of sulfate- and iron-reducing diazotrophs. High N2 fixation further coincided with bioirrigation activity caused by burrowing macrofauna, both of which showed high rates at the shelf sites and low rates in deeper waters. However, statistical analyses proved that none of these processes and environmental variables were significantly correlated with benthic diazotrophy, which lead to the conclusion that either the key parameter controlling benthic N2 fixation in Mauritanian sediments remains unidentified or that a more complex interaction of control mechanisms exists. N2 fixation rates in Mauritanian sediments were 2.7 times lower than those from the anoxic Peruvian OMZ.

  18. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  19. External fixation of "intertrochanteric" fractures.

    Science.gov (United States)

    Gani, Naseem Ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-10-10

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.

  20. Phase-Contrast Hounsfield Units of Fixated and Non-Fixated Soft-Tissue Samples

    Science.gov (United States)

    Willner, Marian; Fior, Gabriel; Marschner, Mathias; Birnbacher, Lorenz; Schock, Jonathan; Braun, Christian; Fingerle, Alexander A.; Noël, Peter B.; Rummeny, Ernst J.; Pfeiffer, Franz; Herzen, Julia

    2015-01-01

    X-ray phase-contrast imaging is a novel technology that achieves high soft-tissue contrast. Although its clinical impact is still under investigation, the technique may potentially improve clinical diagnostics. In conventional attenuation-based X-ray computed tomography, radiological diagnostics are quantified by Hounsfield units. Corresponding Hounsfield units for phase-contrast imaging have been recently introduced, enabling a setup-independent comparison and standardized interpretation of imaging results. Thus far, the experimental values of few tissue types have been reported; these values have been determined from fixated tissue samples. This study presents phase-contrast Hounsfield units for various types of non-fixated human soft tissues. A large variety of tissue specimens ranging from adipose, muscle and connective tissues to liver, kidney and pancreas tissues were imaged by a grating interferometer with a rotating-anode X-ray tube and a photon-counting detector. Furthermore, we investigated the effects of formalin fixation on the quantitative phase-contrast imaging results. PMID:26322638

  1. Methanotrophy induces nitrogen fixation during peatland development

    Science.gov (United States)

    Larmola, Tuula; Leppänen, Sanna M.; Tuittila, Eeva-Stiina; Aarva, Maija; Merilä, Päivi; Fritze, Hannu; Tiirola, Marja

    2014-01-01

    Nitrogen (N) accumulation rates in peatland ecosystems indicate significant biological atmospheric N2 fixation associated with Sphagnum mosses. Here, we show that the linkage between methanotrophic carbon cycling and N2 fixation may constitute an important mechanism in the rapid accumulation of N during the primary succession of peatlands. In our experimental stable isotope enrichment study, previously overlooked methane-induced N2 fixation explained more than one-third of the new N input in the younger peatland stages, where the highest N2 fixation rates and highest methane oxidation activities co-occurred in the water-submerged moss vegetation. PMID:24379382

  2. Polymeric media for tritium fixation. Supplement I

    International Nuclear Information System (INIS)

    Franz, J.A.; Burger, L.L.

    1976-01-01

    Procedures for the fixation of tritium as TH or THO in two different polymeric media are described. The complete procedure for THO fixation in a polyureylene-polyurethane polumer, including polymer molding procedures and leach tests is presented. The catalytic tritiation of polystyrene under very mild conditions using a rhodium catalyst is also described. Thermal stabilities and cost estimates for the polymers examined under this program are discussed. Organic polymers were found to have attractive features for the fixation and storage of concentrated tritium wastes due to the convenience of fixation procedures and favorable properties of the resulting media

  3. Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Mohammad R. Sobhan

    2016-10-01

    Full Text Available Background: Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient’s quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations.   Methods: Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed’s score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described Results: The injury was unilateral in 11 (78.5% patients and bilateral in 3 (21.5%. Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4% and 1 (7.1% cases, respectively. In this study most patients (85% return to work postoperatively. Conclusion: According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.

  4. Fixation of Selenium by Clay Minerals and Iron Oxides

    DEFF Research Database (Denmark)

    Hamdy, A. A.; Nielsen, Gunnar Gissel

    1977-01-01

    In studying Se fixation, soil components capable of retaining Se were investigated. The importance of Fe hydrous oxides in the fixation of Se was established. The clay minerals common to soils, such as kaolinite, montmorillonite and vermiculite, all exhibited Se fixation, but greater fixation occ...

  5. A relation to predict the failure of materials and potential application to volcanic eruptions and landslides.

    Science.gov (United States)

    Hao, Shengwang; Liu, Chao; Lu, Chunsheng; Elsworth, Derek

    2016-06-16

    A theoretical explanation of a time-to-failure relation is presented, with this relationship then used to describe the failure of materials. This provides the potential to predict timing (tf - t) immediately before failure by extrapolating the trajectory as it asymptotes to zero with no need to fit unknown exponents as previously proposed in critical power law behaviors. This generalized relation is verified by comparison with approaches to criticality for volcanic eruptions and creep failure. A new relation based on changes with stress is proposed as an alternative expression of Voight's relation, which is widely used to describe the accelerating precursory signals before material failure and broadly applied to volcanic eruptions, landslides and other phenomena. The new generalized relation reduces to Voight's relation if stress is limited to increase at a constant rate with time. This implies that the time-derivatives in Voight's analysis may be a subset of a more general expression connecting stress derivatives, and thus provides a potential method for forecasting these events.

  6. Evaluation of functional outcome of pilon fractures managed with limited internal fixation and external fixation: A prospective clinical study.

    Science.gov (United States)

    Meena, Umesh Kumar; Bansal, Mahesh Chand; Behera, Prateek; Upadhyay, Rahul; Gothwal, Gyan Chand

    2017-11-01

    The management of pilon fractures is controversial primarily due to the high rate of complications irrespective of the mode of treatment. Limited internal fixation with external fixation is associated with minimal soft tissue handling. This may reduce the chances of wound dehiscence and infection. This study was designed to evaluate the functional and clinical outcomes in patients treated with limited internal fixation combined with external fixation in pilon fractures. This study was conducted as a prospective clinical study on 56 skeletally mature patients with closed fractures with poor skin condition, and with open grade 1 and grade 2 distal tibial intra-articular fractures. All patients were treated with combined limited internal fixation and ankle spanning external fixation. All fractures in this series united with an average time period of union of 18.3weeks (ranging from 13 weeks to 30 weeks). There was no non-union in any case. There was malunion in 4 cases, varus malunion (>5 degree) in 2 cases and recurvatum in another 2 cases). Excellent to good functional results were observed in 88% cases based on the modified Ovadia and Beals score. The mean ankle dorsiflexion and planter flexion movements were 10.2±5.3 degrees and 27.4±7.2 degrees respectively. infections occurred in 6 patients which included 4 pin tract infections and 2 superficial wound infection, all 6 healed after removal of pin tract and with oral antibiotics. The technique of combined external fixation with internal fixation is safe and effective management option for intra-articular distal tibial fractures.

  7. A biomechanical evaluation of magnetic resonance imaging-compatible wire in cervical spine fixation.

    Science.gov (United States)

    Scuderi, G J; Greenberg, S S; Cohen, D S; Latta, L L; Eismont, F J

    1993-10-15

    In a bovine cervical spine model, the ultimate and fatigue strengths as well as relative magnetic resonance imaging artifact produced by titanium, cobalt chrome, and stainless-steel wires in various gauges were assessed. Single-cycle and fatigue strength of wire constructs were measured. Although larger wires generally had greater static strength, fatigue strength was mixed. Sixteen-gauge titanium, and all stainless-steel models (22-gauge braided, 18-gauge, and Songer cable) withstood 10,000 cycles without failure, whereas all other constructs rarely could withstand a similar 10,000 cycles. Magnetic resonance imaging was performed on calf cervical spines instrumented with the various materials. Titanium exhibited the least artifact, stainless-steel showed the greatest artifact, and cobalt chrome an intermediate amount. Although titanium wire produces the least amount of magnetic resonance imaging artifact, it remains a poor choice for implant fixation because its notch sensitivity reduces its fatigue resistance compared with stainless steel, which remains the more dependable choice.

  8. Experimental models of hepatotoxicity related to acute liver failure

    Energy Technology Data Exchange (ETDEWEB)

    Maes, Michaël [Department of In Vitro Toxicology and Dermato-Cosmetology, Vrije Universiteit Brussel, Brussels (Belgium); Vinken, Mathieu, E-mail: mvinken@vub.ac.be [Department of In Vitro Toxicology and Dermato-Cosmetology, Vrije Universiteit Brussel, Brussels (Belgium); Jaeschke, Hartmut [Department of Pharmacology, Toxicology and Therapeutics, University of Kansas Medical Center, Kansas City (United States)

    2016-01-01

    Acute liver failure can be the consequence of various etiologies, with most cases arising from drug-induced hepatotoxicity in Western countries. Despite advances in this field, the management of acute liver failure continues to be one of the most challenging problems in clinical medicine. The availability of adequate experimental models is of crucial importance to provide a better understanding of this condition and to allow identification of novel drug targets, testing the efficacy of new therapeutic interventions and acting as models for assessing mechanisms of toxicity. Experimental models of hepatotoxicity related to acute liver failure rely on surgical procedures, chemical exposure or viral infection. Each of these models has a number of strengths and weaknesses. This paper specifically reviews commonly used chemical in vivo and in vitro models of hepatotoxicity associated with acute liver failure. - Highlights: • The murine APAP model is very close to what is observed in patients. • The Gal/ET model is useful to study TNFα-mediated apoptotic signaling mechanisms. • Fas receptor activation is an effective model of apoptosis and secondary necrosis. • The ConA model is a relevant model of auto-immune hepatitis and viral hepatitis. • Multiple time point evaluation needed in experimental models of acute liver injury.

  9. A COMPARATIVE STUDY OF CONSERVATIVE MANAGEMENT VS. EXTERNAL FIXATION OF COMMINUTED DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Kare

    2016-12-01

    Full Text Available BACKGROUND Fracture of the distal radius (‘broken wrist’ is a common clinical problem. It can be treated conservatively usually involving wrist immobilisation in a plaster cast or surgically. A key method of surgical fixation is external fixation. MATERIALS AND METHODS A prospective study was carried out on 66 patients admitted between June 2014 to May 2016 for evaluation of conservative and surgical management of distal radius fractures. RESULTS Excellent, fair or good result was noticed in around 85% of cases managed conservatively and in above 90% of cases managed by external fixator. CONCLUSION There is some evidence to support the use of external fixation for dorsally displaced fractures of the distal radius in adults. Though, there is insufficient evidence to confirm a better functional outcome, external fixation reduces redisplacement gives improved anatomical results and most of the excess surgically-related complications are minor.

  10. Fixation Time for Evolutionary Graphs

    Science.gov (United States)

    Nie, Pu-Yan; Zhang, Pei-Ai

    Evolutionary graph theory (EGT) is recently proposed by Lieberman et al. in 2005. EGT is successful for explaining biological evolution and some social phenomena. It is extremely important to consider the time of fixation for EGT in many practical problems, including evolutionary theory and the evolution of cooperation. This study characterizes the time to asymptotically reach fixation.

  11. Nitrogen fixation in denitrified marine waters.

    Directory of Open Access Journals (Sweden)

    Camila Fernandez

    Full Text Available Nitrogen fixation is an essential process that biologically transforms atmospheric dinitrogen gas to ammonia, therefore compensating for nitrogen losses occurring via denitrification and anammox. Currently, inputs and losses of nitrogen to the ocean resulting from these processes are thought to be spatially separated: nitrogen fixation takes place primarily in open ocean environments (mainly through diazotrophic cyanobacteria, whereas nitrogen losses occur in oxygen-depleted intermediate waters and sediments (mostly via denitrifying and anammox bacteria. Here we report on rates of nitrogen fixation obtained during two oceanographic cruises in 2005 and 2007 in the eastern tropical South Pacific (ETSP, a region characterized by the presence of coastal upwelling and a major permanent oxygen minimum zone (OMZ. Our results show significant rates of nitrogen fixation in the water column; however, integrated rates from the surface down to 120 m varied by ∼30 fold between cruises (7.5±4.6 versus 190±82.3 µmol m(-2 d(-1. Moreover, rates were measured down to 400 m depth in 2007, indicating that the contribution to the integrated rates of the subsurface oxygen-deficient layer was ∼5 times higher (574±294 µmol m(-2 d(-1 than the oxic euphotic layer (48±68 µmol m(-2 d(-1. Concurrent molecular measurements detected the dinitrogenase reductase gene nifH in surface and subsurface waters. Phylogenetic analysis of the nifH sequences showed the presence of a diverse diazotrophic community at the time of the highest measured nitrogen fixation rates. Our results thus demonstrate the occurrence of nitrogen fixation in nutrient-rich coastal upwelling systems and, importantly, within the underlying OMZ. They also suggest that nitrogen fixation is a widespread process that can sporadically provide a supplementary source of fixed nitrogen in these regions.

  12. Nitrogen Fixation in Denitrified Marine Waters

    Science.gov (United States)

    Fernandez, Camila; Farías, Laura; Ulloa, Osvaldo

    2011-01-01

    Nitrogen fixation is an essential process that biologically transforms atmospheric dinitrogen gas to ammonia, therefore compensating for nitrogen losses occurring via denitrification and anammox. Currently, inputs and losses of nitrogen to the ocean resulting from these processes are thought to be spatially separated: nitrogen fixation takes place primarily in open ocean environments (mainly through diazotrophic cyanobacteria), whereas nitrogen losses occur in oxygen-depleted intermediate waters and sediments (mostly via denitrifying and anammox bacteria). Here we report on rates of nitrogen fixation obtained during two oceanographic cruises in 2005 and 2007 in the eastern tropical South Pacific (ETSP), a region characterized by the presence of coastal upwelling and a major permanent oxygen minimum zone (OMZ). Our results show significant rates of nitrogen fixation in the water column; however, integrated rates from the surface down to 120 m varied by ∼30 fold between cruises (7.5±4.6 versus 190±82.3 µmol m−2 d−1). Moreover, rates were measured down to 400 m depth in 2007, indicating that the contribution to the integrated rates of the subsurface oxygen-deficient layer was ∼5 times higher (574±294 µmol m−2 d−1) than the oxic euphotic layer (48±68 µmol m−2 d−1). Concurrent molecular measurements detected the dinitrogenase reductase gene nifH in surface and subsurface waters. Phylogenetic analysis of the nifH sequences showed the presence of a diverse diazotrophic community at the time of the highest measured nitrogen fixation rates. Our results thus demonstrate the occurrence of nitrogen fixation in nutrient-rich coastal upwelling systems and, importantly, within the underlying OMZ. They also suggest that nitrogen fixation is a widespread process that can sporadically provide a supplementary source of fixed nitrogen in these regions. PMID:21687726

  13. Variable Nitrogen Fixation in Wild Populus.

    Directory of Open Access Journals (Sweden)

    Sharon L Doty

    Full Text Available The microbiome of plants is diverse, and like that of animals, is important for overall health and nutrient acquisition. In legumes and actinorhizal plants, a portion of essential nitrogen (N is obtained through symbiosis with nodule-inhabiting, N2-fixing microorganisms. However, a variety of non-nodulating plant species can also thrive in natural, low-N settings. Some of these species may rely on endophytes, microorganisms that live within plants, to fix N2 gas into usable forms. Here we report the first direct evidence of N2 fixation in the early successional wild tree, Populus trichocarpa, a non-leguminous tree, from its native riparian habitat. In order to measure N2 fixation, surface-sterilized cuttings of wild poplar were assayed using both 15N2 incorporation and the commonly used acetylene reduction assay. The 15N label was incorporated at high levels in a subset of cuttings, suggesting a high level of N-fixation. Similarly, acetylene was reduced to ethylene in some samples. The microbiota of the cuttings was highly variable, both in numbers of cultured bacteria and in genetic diversity. Our results indicated that associative N2-fixation occurred within wild poplar and that a non-uniformity in the distribution of endophytic bacteria may explain the variability in N-fixation activity. These results point to the need for molecular studies to decipher the required microbial consortia and conditions for effective endophytic N2-fixation in trees.

  14. Progressive slip after removal of screw fixation in slipped capital femoral epiphysis: two case reports

    NARCIS (Netherlands)

    Engelsma, Y.; Morgenstern, P.; van der Sluijs, J.A.; Witbreuk, M.M.

    2012-01-01

    Introduction. In slipped capital femoral epiphysis the femoral neck displaces relative to the head due to weakening of the epiphysis. Early recognition and adequate surgical fixation is essential for a good functional outcome. The fixation should be secured until the closure of the epiphysis to

  15. Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture

    OpenAIRE

    Wu, Ai-Min; Jin, Hai-Ming; Lin, Zhong-Ke; Chi, Yong-Long; Wang, Xiang-Yang

    2017-01-01

    Background The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Methods Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 trans...

  16. Improving Saliency Models by Predicting Human Fixation Patches

    KAUST Repository

    Dubey, Rachit

    2015-04-16

    There is growing interest in studying the Human Visual System (HVS) to supplement and improve the performance of computer vision tasks. A major challenge for current visual saliency models is predicting saliency in cluttered scenes (i.e. high false positive rate). In this paper, we propose a fixation patch detector that predicts image patches that contain human fixations with high probability. Our proposed model detects sparse fixation patches with an accuracy of 84 % and eliminates non-fixation patches with an accuracy of 84 % demonstrating that low-level image features can indeed be used to short-list and identify human fixation patches. We then show how these detected fixation patches can be used as saliency priors for popular saliency models, thus, reducing false positives while maintaining true positives. Extensive experimental results show that our proposed approach allows state-of-the-art saliency methods to achieve better prediction performance on benchmark datasets.

  17. Improving Saliency Models by Predicting Human Fixation Patches

    KAUST Repository

    Dubey, Rachit; Dave, Akshat; Ghanem, Bernard

    2015-01-01

    There is growing interest in studying the Human Visual System (HVS) to supplement and improve the performance of computer vision tasks. A major challenge for current visual saliency models is predicting saliency in cluttered scenes (i.e. high false positive rate). In this paper, we propose a fixation patch detector that predicts image patches that contain human fixations with high probability. Our proposed model detects sparse fixation patches with an accuracy of 84 % and eliminates non-fixation patches with an accuracy of 84 % demonstrating that low-level image features can indeed be used to short-list and identify human fixation patches. We then show how these detected fixation patches can be used as saliency priors for popular saliency models, thus, reducing false positives while maintaining true positives. Extensive experimental results show that our proposed approach allows state-of-the-art saliency methods to achieve better prediction performance on benchmark datasets.

  18. Resorbable screws for fixation of autologous bone grafts

    NARCIS (Netherlands)

    Raghoebar, GM; Liem, RSB; Bos, RRM; van der Wal, JE; Vissink, A

    The aim of this study was to evaluate the suitability of resorbable screws made of poly (D,L-lactide) acid (PDLLA) for fixation of autologous bone grafts related to graft regeneration and osseointegration of dental implants. In eight edentulous patients suffering from insufficient retention of their

  19. Improving food and agricultural production. Thailand. Biological nitrogen fixation

    International Nuclear Information System (INIS)

    Bowen, G.D.

    1991-01-01

    The aim of the mission was to assist the counterpart scientists in the analysis and interpretation of data relating to nitrogen fixation studies on grain legumes. The report briefly summarizes the discussions that were held with the counterparts

  20. How Life History Can Sway the Fixation Probability of Mutants

    Science.gov (United States)

    Li, Xiang-Yi; Kurokawa, Shun; Giaimo, Stefano; Traulsen, Arne

    2016-01-01

    In this work, we study the effects of demographic structure on evolutionary dynamics when selection acts on reproduction, survival, or both. In contrast to the previously discovered pattern that the fixation probability of a neutral mutant decreases while the population becomes younger, we show that a mutant with a constant selective advantage may have a maximum or a minimum of the fixation probability in populations with an intermediate fraction of young individuals. This highlights the importance of life history and demographic structure in studying evolutionary dynamics. We also illustrate the fundamental differences between selection on reproduction and selection on survival when age structure is present. In addition, we evaluate the relative importance of size and structure of the population in determining the fixation probability of the mutant. Our work lays the foundation for also studying density- and frequency-dependent effects in populations when demographic structures cannot be neglected. PMID:27129737

  1. Primary fixation of mini slings: a comparative biomechanical study in vivo

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2012-04-01

    Full Text Available INTRODUCTION AND OBJECTIVES: The mini sling concept for stress urinary incontinence is an anatomical approach that involves placing a midurethral low-tension tape anchored to the obturator internus muscles bilaterally. They overcome the blind passage of long needles and all the related complications. There are many different devices available and because these are outpatient procedures, primary fixation plays an important role in the outcome. The objective is to evaluate the primary fixation of the various devices of attachment of the commercially available mini-slings through biomechanical tests. MATERIALS AND METHODS: A total of 45 Wistar rats were divided in 3 groups of 15 rats each. They underwent 5 subcutaneous implantation of different mini slings and one polipropilene mesh (control, as follows: TVT-Secur® (Gynecare, USA, Type 1 polypropylene mesh (control; Ophira Mini Sling System® (Promedon, Argentina, Tissue Fixation System® (TFS PTY, Australia, Zipper Sling® and "T device" (Prosurg, USA. The abdominal wall was removed on bloc at different times after implant for biomechanical evaluation, which consisted in application of unidirectional force to the extremity of the fixation system or mesh, until it was completely removed from the tissue using a tension meter (Nexygen 3.0 Universal Testing Machine - LLOYD Instruments. The force was measured in Newtons (N. RESULTS: There was significant difference in the resistance to extraction among the different fixation systems. At 7 days the Ophira Mini Sling System® presented the best fixation and "T dispositive" the worst. CONCLUSION: Ophira mini sling System® presented the best primary fixation at 7º, 14º and 30º days. The impact of this feature in the clinical setting needs to be verified.

  2. [Effect of iliolumbar fixation in patients with Tile C pelvic injury and analysis of relative factors].

    Science.gov (United States)

    Ge, Zhenxin; Wang, Ben; Zhang, Dongzheng; Liu, Zhaojie; Zhang, Yinguang; Jia, Jian

    2012-11-01

    To explore the relative prognostic factors of Tile C pelvic injury after iliolumbar fixation. Between March 2007 and March 2010, 60 patients with Tile C pelvic injuries were surgically treated with iliolumbar fixation, including 39 males and 21 females with an average age of 37 years (range, 17-66 years). Of them, 27 cases were classified as Tile C1, 20 as Tile C2, and 13 as Tile C3. The preoperative injury severity score (ISS) was 12-66 (mean, 29.4). The time from injury to surgery was 2-25 days (mean, 8.1 days). Iliolumbar fixation was performed in all patients. Unconditional logistic analysis was used to analyze the relationship between the age, sex, body mass index (BMI), operation opportunity, the preoperative combined injury, classification of fracture, the postoperative complication, reduction outcome, sacral nerve injury, and the time of physical exercise and the prognosis. All 60 patients were followed up 12-56 months (mean, 27.3 months). Infection of incisions occurred in 12 cases and were cured after dressing change; healing of incision by first intention was obtained in the other patients. Delay sacral nerve injury was found in 15 patients, 6 patients underwent nerve decompression, and 9 underwent conservative treatment. Ten patients had nail protrusion of Schanz screws at the posterior superior illac spine, and 3 patients had pain, which was relieved after removal of the internal fixator. One patient had bone-grafting nonunion of sacroiliac joint, which was improved by pressured bone graft. Five patients had the beam breakage without significant effect. Six patients had deep vein thrombosis, among them 4 underwent filter and 2 underwent nonsurgical treatment. The healing time of fracture was 3-6 months (mean, 3.9 months). According to the Matta function score, the results were excellent in 31 cases, good in 24 cases, fair in 3 cases, and poor in 2 cases with an excellent and good rate of 91.7% at last follow-up. Majeed score was 58-100 (mean, 86), 28

  3. The effects of fixation of the ulna to the radius in young foals

    International Nuclear Information System (INIS)

    Clem, M.F.; DeBowes, R.M.; Douglass, J.P.; Leipold, H.W.; Chalman, J.A.

    1988-01-01

    The effects of radioulnar fixation were studied in 21 Quarter horse foals by applying a bone plate to the caudal aspect of the proximal part of the ulna, with screws engaging both the radius and the ulna. The plates were applied at 1 month of age in six foals (group I), 5 months of age in six foals (group II), and 7 months of age in three foals (group III). Six foals underwent sham operations at 1 month of age to serve as controls (group IV). Ulnar dysplasia and elbow subluxation developed in all treated foals. The magnitude of ulnar dysplasia was inversely related to the patient's age at fixation and was accompanied by degenerative joint disease and lameness in foals undergoing fixation at 1 and 5 months of age. Removal of the fixation appliances 16 weeks after implantation in three foals from each of groups I and II failed to reverse the degree of ulnar dysplasia. Although foals undergoing fixation at 7 months of age (group III) were not lame, radiographic evidence of subluxation and subtle degenerative changes in the articular cartilage of the treated elbow did develop. Recommendations for avoidance of radioulnar fixation were developed from these observations

  4. Characteristics and Outcomes of Pediatric Heart Failure-Related Emergency Department Visits in the United States: A Population-Based Study.

    Science.gov (United States)

    Mejia, Erika J; O'Connor, Matthew J; Lin, Kimberly Y; Song, Lihai; Griffis, Heather; Mascio, Christopher E; Shamszad, Pirouz; Donoghue, Aaron; Ravishankar, Chitra; Shaddy, Robert E; Rossano, Joseph W

    2018-02-01

    To describe the frequency, characteristics, and outcomes of heart failure-related emergency department (ED) visits in pediatric patients. We aimed to test the hypothesis that these visits are associated with higher admission rates, mortality, and resource utilization. A retrospective analysis of the Nationwide Emergency Department Sample for 2010 of patients ≤18 years of age was performed to describe ED visits with and without heart failure. Cases were identified using International Classification of Disease, Ninth Revision, Clinical Modification codes and assessed for factors associated with admission, mortality, and resource utilization. Among 28.6 million pediatric visits to the ED, there were 5971 (0.02%) heart failure-related cases. Heart failure-related ED patients were significantly more likely to be admitted (59.8% vs 4.01%; OR 35.3, 95% CI 31.5-39.7). Among heart failure-related visits, admission was more common in patients with congenital heart disease (OR 5.0, 95% CI 3.3-7.4) and in those with comorbidities including respiratory failure (OR 78.3, 95% CI 10.4-591) and renal failure (OR 7.9, 95% CI 1.7-36.3). Heart failure-related cases admitted to the hospital had a higher likelihood of death than nonheart failure-related cases (5.9% vs 0.32%, P failure (OR 4.5, 95% CI 2.2-9.2) and renal failure (OR 7.8, 95% CI 2.9-20.7). Heart failure-related ED visits were more expensive than nonheart failure-related ED visits ($1460 [IQR $861-2038] vs $778 [IQR $442-1375] [P failure-related visits represent a minority of pediatric ED visits but are associated with increased hospital admission and resource utilization. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Management of the proximal tibia fractures by mini external fixation: A case series of 30 cases

    Directory of Open Access Journals (Sweden)

    Samar K Biswas

    2014-01-01

    Full Text Available Background: Management of high velocity trauma is a challenging problem because of morbidity of trauma and sometime residual problems of failure of proper healing of fractures with the restriction of movements of knee, shortening, and added risk of compartment syndrome in the proximal tibia fracture. There is always risk of post-operative infection and infected non-union in extensive open surgical procedure and internal fixation. Hence, there is always look out for the middle path procedure for a solution to the above said problems with the added advantage of less hospital stay and early return to work by minimal invasive procedure and stabilization of fracture reduction by multiple K-wire fixation with a frame applied externally. Stabilization of fracture with reduced pain allows early movements of neighbouring joint knee and ankle; hence, reduces the chances of fracture diseases. With this we have been stimulated to take-up the study of managing the proximal tibia fracture by mini external fixator. Aim: The aim of this study was to manage proximal tibia fractures by mini external fixator and evaluate the results and efficacy of this method. Material and Method: A total of 30 patients having proximal tibial fractures admitted at our center between 2008 and 2010 were taken and the procedure carried out was closed manipulative reduction and stabilization with mini external fixator. All acute proximal tibia fractures including tibial plateau fractures above 17 years of age of either sex were included in the study. Fracture more than 3 weeks old were excluded from the study. Result: Out of 30 cases 13 were excellent, 14 cases good, and 3 showed fair. It was found that type 5 and 6 of Schatzker′s classification have lesser outcome type of fractures Conclusion: We have found that management of the proximal tibia fractures by mini external fixation method has a better outcome. Early mobilization of knee in the proximal tibia fractures after

  6. Outcomes and Complications of Scleral-Fixated Intraocular Lens Combined with Ahmed Tube Surgery

    Directory of Open Access Journals (Sweden)

    Nikhel Sachdev

    2018-01-01

    Full Text Available Background. To evaluate the outcome and complications of transscleral suture-fixated posterior chamber intraocular lens (PCIOL implantation combined with Ahmed glaucoma valve (AGV surgery in Asian eyes. Design. This was a retrospective study that included 22 eyes from 22 participants. The surgeries were performed at Singapore’s National University Hospital. Participants underwent an Ahmed tube surgery, together with transscleral suture-fixated posterior chamber intraocular lens. Main Outcome Measures. Complete success was defined as 6 ≤ intraocular pressure (IOP ≤ 21 mmHg without medications at the last follow-up visit, with no reoperation required and no progression to no perception of light (NPL. Results. At the last follow-up, there was a significant reduction in mean IOP (22.4 ± 6.5 mmHg versus 13.9 ± 3.9 mmHg; p<0.001 and mean number of intraocular pressure-lowering medications (2.45 ± 1.30 versus 0.05 ± 0.21; p<0.001. There was no significant change in visual acuity [1.43 ± 1.21 (LogMAR versus 1.09 ± 1.31 (p=0.204]. Sixteen eyes (72.7% achieved complete success. The 3 commonest complications were bullous keratopathy, choroidal detachment, and displacement of intraocular lens. Conclusion and Relevance. This technique showed good success for intraocular pressure control and vision preservation. Postoperative complications were relatively common although most were self-limiting. Patients at increased risk of trabeculectomy failure may be suitable for this procedure.

  7. Maxwellian Eye Fixation during Natural Scene Perception

    Directory of Open Access Journals (Sweden)

    Jean Duchesne

    2012-01-01

    Full Text Available When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell’s law for each participant and for each scene condition (normal or scrambled. The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes.

  8. Maxwellian Eye Fixation during Natural Scene Perception

    Science.gov (United States)

    Duchesne, Jean; Bouvier, Vincent; Guillemé, Julien; Coubard, Olivier A.

    2012-01-01

    When we explore a visual scene, our eyes make saccades to jump rapidly from one area to another and fixate regions of interest to extract useful information. While the role of fixation eye movements in vision has been widely studied, their random nature has been a hitherto neglected issue. Here we conducted two experiments to examine the Maxwellian nature of eye movements during fixation. In Experiment 1, eight participants were asked to perform free viewing of natural scenes displayed on a computer screen while their eye movements were recorded. For each participant, the probability density function (PDF) of eye movement amplitude during fixation obeyed the law established by Maxwell for describing molecule velocity in gas. Only the mean amplitude of eye movements varied with expertise, which was lower in experts than novice participants. In Experiment 2, two participants underwent fixed time, free viewing of natural scenes and of their scrambled version while their eye movements were recorded. Again, the PDF of eye movement amplitude during fixation obeyed Maxwell's law for each participant and for each scene condition (normal or scrambled). The results suggest that eye fixation during natural scene perception describes a random motion regardless of top-down or of bottom-up processes. PMID:23226987

  9. Overcoming design fixation through education and creativity methods

    DEFF Research Database (Denmark)

    Howard, Thomas J.; Maier, Anja; Onarheim, Balder

    2013-01-01

    . The first intervention consisted of educating each team on the phenomena and effects of design fixation. The results showed that this intervention reduced the number of fixation elements in comparison to the control group (p=0.025). The second intervention involved using Dix et als' (2006) 'Bad Ideas...... of ideas produced per group and the groups' fixation ratios, adding to the quantity breads novelty debate. Finally, the study also provided further evidence of the hypothesis by Agogué et al (2011) that example solutions constructed from restrictive partitions have a greater fixation affect....

  10. STUDY ON SPANNING EXTERNAL FIXATORS FOR PERIARTICULAR OPEN FRACTURES

    Directory of Open Access Journals (Sweden)

    Prasanth Maddila

    2017-04-01

    Full Text Available BACKGROUND Open fractures which occur close to any fracture need immobilisation for the soft tissues to heal. Some open fractures are even fixed with provisional fixations to maintain the alignment of the fractures. The provisional fixation needs to be augmented with external support, which can be given by spanning external fixators across a joint. MATERIALS AND METHODS Our study consists of 38 open fractures of the lower limbs, which are of Gustilo-Anderson’s type IIIB, an MT4 of AO-ASIF soft tissue injury classification essentially requiring open wound management as well as fracture fixation. Wound lavage and debridements are carried out till the soft tissues show granulations. The position in which joint is immobilised is functional and with access to open wound for dressings and inspection without any displacement of the fracture as well as creeping granulation tissue. RESULTS All the cases in our study are maintained with functional position till soft tissue cover is achieved and provisional fixation is done with definitive fixation after soft tissue cover with skin grafting. CONCLUSION Spanning external fixators are useful in maintaining functional positions as well as augmenting the provisional fixation of the compound fractures.

  11. Evaluation of body image and self-esteem in patients with external fixation devices: a Turkish perspective.

    Science.gov (United States)

    Büyükyilmaz, Funda; Sendir, Merdiye; Salmond, Susan

    2009-01-01

    This descriptive study aimed to describe the body image and self-esteem of patients with external fixation devices. Fifty patients with external fixation devices who came for follow-up to the Ilizarov Outpatient Clinic of a university hospital in Turkey were included in this study. Data were collected by using a Demographic Questionnaire Form, Multidimensional Body-Self Relations Questionnaire (MBSRQ), and Coppersmith Self-Esteem Inventory. The perceived body image (197.58 +/- 25.14) and self-esteem (65.28 +/- 17.97) of the patients with external fixation devices were in the moderate range. There was no significant correlation between body image and self-esteem. Self-esteem was correlated with one's perception of whether external fixation impacted one's appearance and whether one wanted to avoid being seen by certain individuals because of the appearance of the external fixator. The study highlighted that body image disturbance and threats to self-esteem are not universal with the use of external fixation and need to be assessed individually.

  12. Internal Versus External Fixation of Charcot Midfoot Deformity Realignment.

    Science.gov (United States)

    Lee, Daniel J; Schaffer, Joseph; Chen, Tien; Oh, Irvin

    2016-07-01

    Internal and external fixation techniques have been described for realignment and arthrodesis of Charcot midfoot deformity. There currently is no consensus on the optimal method of surgical reconstruction. This systematic review compared the clinical results of surgical realignment with internal and external fixation, specifically in regard to return to functional ambulation, ulcer occurrence, nonunion, extremity amputation, unplanned further surgery, deep infection, wound healing problems, peri- or intraoperative fractures, and total cases with any complication. A search of multiple databases for all relevant articles published from January 1, 1990, to March 22, 2014, was performed. A logistic regression model evaluated each of the outcomes and its association with the type of fixation method. The odds of returning to functional ambulation were 25% higher for internal fixation (odds ratio [OR], 1.259). Internal fixation had a 42% reduced rate of ulcer occurrence (OR, 0.578). External fixation was 8 times more likely to develop radiographic nonunion than internal fixation (OR, 8.2). Internal fixation resulted in a 1.5-fold increase in extremity amputation (OR, 1.488), a 2-fold increase in deep infection (OR, 2.068), a 3.4-fold increase in wound healing complications (OR, 3.405), and a 1.5-fold increase in the total number of cases experiencing any complication (OR, 1.525). This was associated with a 20% increase in the need for unplanned further surgery with internal fixation (OR, 1.221). Although internal fixation may decrease the risk of nonunion and increase return to functional ambulation, it had a higher rate of overall complications than external fixation for realignment and arthrodesis of Charcot midfoot deformity. [Orthopedics. 2016; 39(4):e595-e601.]. Copyright 2016, SLACK Incorporated.

  13. Coupling failure between stem and femoral component in a constrained revision total knee arthroplasty.

    LENUS (Irish Health Repository)

    Butt, Ahsan Javed

    2013-02-01

    Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use of a cemented femoral stem, screw fixation and the metaphyseal sleeve of an S-ROM modular hip system (DePuy international Ltd).

  14. Outcome of rail fixator system in reconstructing bone gap

    Directory of Open Access Journals (Sweden)

    Amit Lakhani

    2014-01-01

    Conclusion: All patients well tolerated rail fixator with good functional results and gap reconstruction. Easy application of rail fixator and comfortable distraction procedure suggest rail fixator a good alternative for gap reconstruction of limbs.

  15. Fixation Characteristics of Severe Amblyopia Subtypes: Which One is Worse?

    Science.gov (United States)

    Koylu, Mehmet Talay; Ozge, Gokhan; Kucukevcilioglu, Murat; Mutlu, Fatih Mehmet; Ceylan, Osman Melih; Akıncıoglu, Dorukcan; Ayyıldız, Onder

    2017-01-01

    To determine differences in macular sensitivity and fixation patterns in different subtypes of severe amblyopia. This case-control study enrolled a total of 73 male adults, including 18 with pure strabismic severe amblyopia, 19 with pure anisometropic severe amblyopia, 18 with mixed (strabismic plus anizometropic) severe amblyopia, and 18 healthy controls. MP-1 microperimetry was used to evaluate macular sensitivity, location of fixation, and stability of fixation. Mean macular sensitivity, stability of fixation, and location of fixation were significantly worse in all amblyopia subtypes when compared with healthy controls. Intergroup comparisons between amblyopia subtypes revealed that mean macular sensitivity, stability of fixation, and location of fixation were significantly worse in pure strabismic and mixed amblyopic eyes when compared with pure anisometropic amblyopic eyes. Strabismus seems to be a worse prognostic factor in severe amblyopia than anisometropia in terms of fixation characteristics and retinal sensitivity.

  16. Failure trend analysis for safety related components of Korean standard NPPs

    International Nuclear Information System (INIS)

    Choi, Sun Yeong; Han, Sang Hoon

    2005-01-01

    The component reliability data of Korean NPP that reflects the plant specific characteristics is required necessarily for PSA of Korean nuclear power plants. We have performed a project to develop the component reliability database (KIND, Korea Integrated Nuclear Reliability Database) and S/W for database management and component reliability analysis. Based on the system, we have collected the component operation data and failure/repair data during from plant operation date to 2002 for YGN 3, 4 and UCN 3, 4 plants. Recently, we provided the component failure rate data for UCN 3, 4 standard PSA model from the KIND. We evaluated the components that have high-ranking failure rates with the component reliability data from plant operation date to 1998 and 2000 for YGN 3,4 and UCN 3, 4 respectively. We also identified their failure mode that occurred frequently. In this study, we analyze the component failure trend and perform site comparison based on the generic data by using the component reliability data which is extended to 2002 for UCN 3, 4 and YGN 3, 4 respectively. We focus on the major safety related rotating components such as pump, EDG etc

  17. Fixation Probability in a Haploid-Diploid Population.

    Science.gov (United States)

    Bessho, Kazuhiro; Otto, Sarah P

    2017-01-01

    Classical population genetic theory generally assumes either a fully haploid or fully diploid life cycle. However, many organisms exhibit more complex life cycles, with both free-living haploid and diploid stages. Here we ask what the probability of fixation is for selected alleles in organisms with haploid-diploid life cycles. We develop a genetic model that considers the population dynamics using both the Moran model and Wright-Fisher model. Applying a branching process approximation, we obtain an accurate fixation probability assuming that the population is large and the net effect of the mutation is beneficial. We also find the diffusion approximation for the fixation probability, which is accurate even in small populations and for deleterious alleles, as long as selection is weak. These fixation probabilities from branching process and diffusion approximations are similar when selection is weak for beneficial mutations that are not fully recessive. In many cases, particularly when one phase predominates, the fixation probability differs substantially for haploid-diploid organisms compared to either fully haploid or diploid species. Copyright © 2017 by the Genetics Society of America.

  18. Two viewpoints for software failures and their relation in probabilistic safety assessment of digital instrumentation and control systems

    International Nuclear Information System (INIS)

    Kim, Man Cheol

    2015-01-01

    As the use of digital systems in nuclear power plants increases, the reliability of the software becomes one of the important issues in probabilistic safety assessment. In this paper, two viewpoints for a software failure during the operation of a digital system or a statistical software test are identified, and the relation between them is provided. In conventional software reliability analysis, a failure is mainly viewed with respect to the system operation. A new viewpoint with respect to the system input is suggested. The failure probability density functions for the two viewpoints are defined, and the relation between the two failure probability density functions is derived. Each failure probability density function can be derived from the other failure probability density function by applying the derived relation between the two failure probability density functions. The usefulness of the derived relation is demonstrated by applying it to the failure data obtained from the software testing of a real system. The two viewpoints and their relation, as identified in this paper, are expected to help us extend our understanding of the reliability of safety-critical software. (author)

  19. Fixation and escape times in stochastic game learning

    International Nuclear Information System (INIS)

    Realpe-Gomez, John; Szczesny, Bartosz; Galla, Tobias; Dall’Asta, Luca

    2012-01-01

    Evolutionary dynamics in finite populations is known to fixate eventually in the absence of mutation. We here show that a similar phenomenon can be found in stochastic game dynamical batch learning, and investigate fixation in learning processes in a simple 2×2 game, for two-player games with cyclic interaction, and in the context of the best-shot network game. The analogues of finite populations in evolution are here finite batches of observations between strategy updates. We study when and how such fixation can occur, and present results on the average time-to-fixation from numerical simulations. Simple cases are also amenable to analytical approaches and we provide estimates of the behaviour of so-called escape times as a function of the batch size. The differences and similarities with escape and fixation in evolutionary dynamics are discussed. (paper)

  20. External fixation of “intertrochanteric” fractures

    Science.gov (United States)

    Gani, Naseem ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool

    2009-01-01

    In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with “intertrochanteric” fractures remain unsuita ble for open reduction and internal fixation. The aim of this study was to analyze the results of external fixation of “intertrochanteric” fractures in high-risk geriatric patients in a developing country. The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58–90 years) with “intertrochanteric” fractures, in whom external fixation was performed, are reported. Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients. This study demonstrated that external fixation of “intertrochantric” fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country. PMID:21808680

  1. External fixation of “intertrochanteric” fractures

    Directory of Open Access Journals (Sweden)

    Naseem ul Gani

    2009-08-01

    Full Text Available In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with “intertro-chanteric” fractures remain unsuitable for open reduction and internal fixation. The aim of this study was to analyze the results of external fixation of “intertro-chanteric” fractures in high-risk geriatric patients in a developing country. The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years with “intertrochanteric” fractures, in whom external fixation was performed, are reported. Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet’s point system. Good to excellent results were achieved in 44 patients. This study demonstrated that external fixation of “intertrochantric” fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.

  2. Photosynthate partitioning and nitrogen fixation of alfalfa and birdsfoot trefoil

    International Nuclear Information System (INIS)

    Shieh, W.J.

    1985-01-01

    Nodule mass and number are usually correlated with rates of nitrogen fixation in legumes. Birdsfoot trefoil (Lotus corniculatus L.) with more than twice the nodule number and mass, however, fixes far less nitrogen than alfalfa (Medicago sativa L.) at the same age. In this research, photosynthesis and photosynthate partitioning and utilization in relation to nitrogen fixation of alfalfa and birdsfoot trefoil were examined in order to determine their relationship to nitrogen fixation potential. Photosynthate to nodules was studied using 14 CO 2 labeling techniques. Partitioning patterns were altered by shading and dark depletion treatments. Efficiency of photosynthate utilization was examined by determining turnover of 14 C photosynthate in nodule metabolites and by studying rates of cyanide-resistant and cyanide-sensitive O 2 uptake. Alfalfa nodule activity was greater than trefoil expressed on a hole pot or nodule dry weight basis. Both shading and dark treatments significantly reduced nodule activity as estimated by the acetylene reduction assay. Shoots of both species were found to be the dominant sinks for photosynthate. Percentage 14 C recovered in alfalfa roots was more than twice that of trefoil at 1,2,3,4 and 24 h after labeling. Greater relative specific radioactivity (RSA) in nodules of both species suggests that they were stronger sinks for current photosynthate than roots

  3. Local authorities facing flood related networks failures in France

    Directory of Open Access Journals (Sweden)

    Gallet Violette

    2016-01-01

    Full Text Available Network critical infrastructures have become vital to keep our societies running in every-day situations, but also during crisis and recovery. Involving many stakeholders at different scales, they form a complex system that can be easily disturbed by internal or external events, because then all the dependencies that allow to optimizing their working become flaws that help failures to spread beyond the flooded area and from one network to another. Thus every flood reminds us how vulnerable infrastructures are and how much it costs when they fail. But whereas it isn’t so difficult to adapt new urban development, what about all the existing and exposed infrastructures? CEPRI carried out research on encountered difficulties and good practices to understand the situation and consider improvement opportunities. We worked out three steps to a better territory resilience to flood. First, get a better knowledge of networks. Then, as far as possible, reduce networks vulnerability. Finally, as risks of network failures always remain, get prepared to cope with disruptions! CEPRI gathered many experiences to illustrate and strengthen its work, which aims at helping local authorities to reduce their vulnerability to flood and related networks failures.

  4. The influence on the contact condition and initial fixation stability of the main design parameters of a self-expansion type anterior cruciate ligament fixation device

    International Nuclear Information System (INIS)

    Kim, Jong Dae; Oh, Chae Youn; Kim, Cheol Sang

    2008-01-01

    This paper proposes a self-expansion type anterior cruciate ligament fixation device. The proposed fixation device provides graft fixation force by maintaining contact with the bone tunnel. Since the device maintains contact with the bone tunnel by the force that expands by the self-driven elastic force of the device, the main design parameters that determine the performance of this device are the ring thickness and expansion angle. This paper develops the three-dimensional finite element models of the fixation device and bone. By simulation with the developed finite element model, this paper studies the influence of the main design parameters of the device on the maximum stress around the ring when grasping the fixation device. Through the analysis of the stress on the bone tunnel wall when the fixation device comes in contact with the bone tunnel, this paper shows the influence of the main design parameters of the fixation device on the contact condition. In addition, through the analysis of the migration that occur upon application of the pull-out force, this paper studies the influence of the main design parameters on the initial fixation stability of the fixation device

  5. The influence on the contact condition and initial fixation stability of the main design parameters of a self-expansion type anterior cruciate ligament fixation device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Dae [Jeonju University, Jeonju (Korea, Republic of); Oh, Chae Youn; Kim, Cheol Sang [Chonbuk National University, Jeonju (Korea, Republic of)

    2008-12-15

    This paper proposes a self-expansion type anterior cruciate ligament fixation device. The proposed fixation device provides graft fixation force by maintaining contact with the bone tunnel. Since the device maintains contact with the bone tunnel by the force that expands by the self-driven elastic force of the device, the main design parameters that determine the performance of this device are the ring thickness and expansion angle. This paper develops the three-dimensional finite element models of the fixation device and bone. By simulation with the developed finite element model, this paper studies the influence of the main design parameters of the device on the maximum stress around the ring when grasping the fixation device. Through the analysis of the stress on the bone tunnel wall when the fixation device comes in contact with the bone tunnel, this paper shows the influence of the main design parameters of the fixation device on the contact condition. In addition, through the analysis of the migration that occur upon application of the pull-out force, this paper studies the influence of the main design parameters on the initial fixation stability of the fixation device

  6. Time-dependent differences in management and microbiology of orthopaedic internal fixation-associated infections: an observational prospective study with 229 patients.

    Science.gov (United States)

    Kuehl, R; Tschudin-Sutter, S; Morgenstern, M; Dangel, M; Egli, A; Nowakowski, A; Suhm, N; Theilacker, C; Widmer, A F

    2018-04-10

    Little information has been published on orthopaedic internal fixation-associated infections. We aimed to analyse time-dependent microbiology, treatment, and outcome. Over a 10-year period, all consecutive patients with internal fixation-associated infections at the University Hospital of Basel, were prospectively followed and clinical, microbiological and outcome data were acquired. Infections were classified as early (0-2 weeks after implantation), delayed (3-10 weeks), and late (>10 weeks). Two hundred and twenty-nine patients were included, with a median follow-up of 773 days (IQR 334-1400). Staphylococcus aureus was the most prevalent pathogen (in 96/229 patients, 41.9%). Enterobacteriaceae were frequent in early infections (13/49, 26.5%), whereas coagulase-negative staphylococci (36/92, 39.1%), anaerobes (15/92, 16.3%) and streptococci (10/92, 10.9%) increased in late revisions. Failure was observed in 27/229 (11.7%). Implants were retained in 42/49 (85.7%) in early, in 51/88 (57.9%) in delayed, and in 9/92 (9.8%) in late revisions (p < 0.01). Early revisions failed in 6/49 (12.2%), delayed in 9/88 (10.2%), and late in 11/92 (13.0%) (p 0.81). Debridement and retention failed in 6/42 (14.3%) for early, in 6/51 (11.8%) for delayed, and in 3/9 (33.3%) for late revisions (p 0.21). Biofilm-active antibiotic therapy tailored to resistance correlated with improved outcome for late revisions failure (6/72, 7.7% versus 6/12, 50.0%; p < 0.01) but not for early revisions failure (5/38, 13.2% versus 1/11, 9.1%; p 1.0). Treatment of internal fixation-associated infections showed a high success rate of 87-90% over all time periods. Implant retention was highly successful in early and delayed infections but only limited in late infections. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  7. Analysis and an overview of fixators in medicine and the methods of processing materials for producing fixators

    Directory of Open Access Journals (Sweden)

    Dalibor Milojko Đenadić

    2013-06-01

    Full Text Available The fixator is a medical device that provides support to fractured biological structures. Metal biomaterials are mainly used for replacing broken or damaged hard tissues such as bones because of their high strenght, toughness and corrosion resistance. Materials such as stainless steel, titanium and aluminium alloys (Ti-6Al-4V, cobalt and chromium alloys, composite materials and other biocompatible materials are used in orthopedy for the stabilization of connective tissue injuries or as a substitute for the bone tissues. Fixators are classified according to the place of installation to external and internal fixators. Widely used medical fixators are pins, rods plates, screws, pipes, wires, nails and external fixators. Conventional and non-conventional methods of processing are used in the production process for all types of fixators. Introduction Fixators are medical devices manufactured to support damaged biological structures. In the field of orthopedic surgery that deals with skeletal disorders such as bone, spine, joints, muscles and tendons injuries and diseases, various metals, titanium and cobalt alloys etc. are used to stabilize the supporting tissue injuries or as a substitute for bone tissues. Metallic implants are frequently used in orthopedic surgery as joint prosthesis (hip, knee and elbow fracture fixation devices (plates, screws, external fixators and devices for the fixation of the spine. In principle, fixators are devided into external and internal ones, depending on the place of installation (outside or inside the body. The most common types of medical fixators are pins, rods and plates. This paper presents some of the most common materials used for the production of fixators, their processing and possibilties of use in medicine for various purposes. Types of fixators and materials used for their production Nowadays, biocompatible materials are usually used for the production of fixators and implants. These materials show good

  8. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure.

    Science.gov (United States)

    Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom

    2005-08-01

    Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.

  9. External Fixation versus two-stage Open Reduction Internal Fixation of distal intra-articular Tibia fractures; a Systematic Review

    DEFF Research Database (Denmark)

    Ladeby Erichsen, Julie; Jensen, Carsten; Damborg, Frank Lindhøj

    Internal Fixation (ORIF) or External Fixation (EF). Method : A search was conducted using PUBMED, Embase, Cochrane Central, Open Grey, Orthopaedic Proceedings and WHO International Clinical Trials Registry Platform. Studies with level of evidence I-IV comparing EF with two-stage ORIF of DIATF in patients...

  10. The importance of nodule CO2 fixation for the efficiency of symbiotic nitrogen fixation in pea at vegetative growth and during pod formation.

    Science.gov (United States)

    Fischinger, Stephanie Anastasia; Schulze, Joachim

    2010-05-01

    Nodule CO2 fixation is of pivotal importance for N2 fixation. The process provides malate for bacteroids and oxaloacetate for nitrogen assimilation. The hypothesis of the present paper was that grain legume nodules would adapt to higher plant N demand and more restricted carbon availability at pod formation through increased nodule CO2 fixation and a more efficient N2 fixation. Growth, N2 fixation, and nodule composition during vegetative growth and at pod formation were studied in pea plants (Pisum sativum L.). In parallel experiments, 15N2 and 13CO2 uptake, as well as nodule hydrogen and CO2 release, was measured. Plants at pod formation showed higher growth rates and N2 fixation per plant when compared with vegetative growth. The specific activity of active nodules was about 25% higher at pod formation. The higher nodule activity was accompanied by higher amino acid concentration in nodules and xylem sap with a higher share of asparagine. Nodule 13CO2 fixation was increased at pod formation, both per plant and per 15N2 fixed unit. However, malate concentration in nodules was only 40% of that during vegetative growth and succinate was no longer detectable. The data indicate that increased N2 fixation at pod formation is connected with strongly increased nodule CO2 fixation. While the sugar concentration in nodules at pod formation was not altered, the concentration of organic acids, namely malate and succinate, was significantly lower. It is concluded that strategies to improve the capability of nodules to fix CO2 and form organic acids might prolong intensive N2 fixation into the later stages of pod formation and pod filling in grain legumes.

  11. Carbon dioxide fixation in isolated Kalanchoe chloroplasts

    Energy Technology Data Exchange (ETDEWEB)

    Levi, C.; Gibbs, M.

    1975-07-01

    Chloroplasts isolated from Kalanchoe diagremontiana leaves were capable of photosynthesizing at a rate of 5.4 ..mu..moles of CO/sub 2/ per milligram of chlorophyll per hour. The dark rate of fixation was about 1 percent of the light rate. A high photosynthetic rate was associated with low starch content of the leaves. Ribose 5-phosphate, fructose 1, 6-diphosphate, and dithiothreitol stimulated fixation, whereas phosphoenolpyruvate and azide were inhibitors. The products of CO/sub 2/ fixation were primarily those of the photosynthetic carbon reduction cycle. (auth)

  12. The effect of hubs and shortcuts on fixation time in evolutionary graphs

    Science.gov (United States)

    Askari, Marziyeh; Moradi Miraghaei, Zeinab; Aghababaei Samani, Keivan

    2017-07-01

    How can a new species (like a gene, an idea, or a strategy) take over the whole of a population? This process, which is called fixation, is considerably affected by the structure of the population. There are two key quantities to quantify the fixation process, namely fixation probability and fixation time. Fixation probability has been vastly studied in recent years, but fixation time has not been completely explored, yet. This is because the discovery of a relationship between fixation time and network structure is quite challenging. In this paper we investigate this relationship for a number of well-known complex networks. We show that the existence of a few high-degree nodes (hubs) in the network results in a longer fixation time, while the existence of a few short-cuts decreases the fixation time. Furthermore we investigate the effect of network parameters, such as connection probability, on fixation time. We show that by increasing the density of edges, fixation time decreases for all types of studied networks. Finally, we survey the effect of rewiring probability in a Watts-Strogatz network on fixation time.

  13. Skin Graft Fixation Using Hydrofiber (Aquacel® Extra).

    Science.gov (United States)

    Yen, Ya-Hui; Lin, Chih-Ming; Hsu, Honda; Chen, Ying-Chen; Chen, Yi-Wen; Li, Wan-Yu; Hsieh, Chia-Nan; Huang, Chieh-Chi

    2018-06-01

    The traditional method of skin graft fixation is with tie-over bollus dressing. The use of splints in the extremities for skin graft fixation is a common practice. However, these splints are heavy and uncomfortable and contribute considerably to our overall medical waste. Hydrofiber (Aquacel Extra) has a strong fluid absorption property and fixates well to the underlying wound once applied. In this study, we used hydrofiber for fixation, avoiding the use of splints after skin grafting. A total of 56 patients reconstructed with split-thickness skin graft that was fixated only with hydrofiber between March 2015 and March 2016 were included in this retrospective study. There were 44 men and 12 women with a mean age of 61 ± 18 years. The defect size ranged from 1 × 1 cm for fingertips to 30 × 12 cm for lower limb defects. The average defect size was 61 ± 78 cm. The mean skin graft take was 96% ± 6%. Because splints were not required, we saved around 48 kg of medical waste over the space of 1 year. The use of hydrofiber for skin graft fixation was effective and technically very simple. Splints were not required with this method, decreasing the medical waste created and increasing patient comfort. We suggest that this is an excellent alternative for skin graft fixation while at the same time decreasing our carbon footprint as surgeons.

  14. Genome-wide association analysis of symbiotic nitrogen fixation in common bean

    Science.gov (United States)

    A genome-wide association study (GWAS) was conducted to explore the genetic basis of variation for symbiotic nitrogen fixation (SNF) and related traits in the Andean diversity panel (ADP) comprised of 259 common bean (Phaseolus vulgaris) genotypes. The ADP was evaluated for SNF and related traits in...

  15. Do you like what you see? The role of first fixation and total fixation duration in consumer choice

    NARCIS (Netherlands)

    Laan, van der L.N.; Hooge, I.T.C.; Ridder, de D.T.D.; Viergever, M.A.; Smeets, P.A.M.

    2015-01-01

    Although there has been recent growing interest in the associations between measures of visual attention and consumer choice, there is still uncertainty about the role of the first fixation in consumer choice and the factors that drive total fixation duration. The study aimed (1) to investigate the

  16. Do you like what you see? : The role of first fixation and total fixation duration in consumer choice

    NARCIS (Netherlands)

    van der Laan, Laura N.; Hooge, Ignace T C; De Ridder, Denise T D; Viergever, Max A.; Smeets, Paul A M

    2015-01-01

    Although there has been recent growing interest in the associations between measures of visual attention and consumer choice, there is still uncertainty about the role of the first fixation in consumer choice and the factors that drive total fixation duration. The study aimed (1) to investigate the

  17. [Case-control study on effects of external fixation combined with limited internal fixation for the treatment of Pilon fractures of Rüedi-Allgower type III].

    Science.gov (United States)

    Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng

    2014-01-01

    To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (Pexternal fixation with limited internal fixation in the treatment of Pilon fracture

  18. Bilateral Laparoscopic Totally Extraperitoneal Repair Without Mesh Fixation

    OpenAIRE

    Dehal, Ahmed; Woodward, Brandon; Johna, Samir; Yamanishi, Frank

    2014-01-01

    Background and Objectives: Mesh fixation during laparoscopic totally extraperitoneal repair is thought to be necessary to prevent recurrence. However, mesh fixation may increase postoperative chronic pain. This study aimed to describe the experience of a single surgeon at our institution performing this operation. Methods: We performed a retrospective review of the medical records of all patients who underwent bilateral laparoscopic totally extraperitoneal repair without mesh fixation for ing...

  19. Prognostic factors for patients with hepatitis B virus-related acute-on-chronic liver failure

    Directory of Open Access Journals (Sweden)

    LI Ying

    2017-03-01

    Full Text Available ObjectiveTo investigate the prognostic factors for patients with hepatitis B virus-related acute-on-chronic liver failure, and to provide a basis for clinical diagnosis and treatment. MethodsA total of 172 patients with hepatitis B virus (HBV-related acute-on-chronic liver failure who were admitted to The First Hospital of Jilin University from January 1, 2006 to January 1, 2016 and had complete medical records and follow-up data were enrolled, and a retrospective analysis was performed for their clinical data and laboratory markers to determine prognostic factors. The independent-samples t test was used for comparison of continuous data between groups, the chi-square test was used for comparison of categorical data between groups, and a multivariate logistic regression analysis was performed for the indices determined to be statistically significant by the univariate analysis to screen out independent risk factors for the prognosis of patients with HBV-related acute-on-chronic liver failure. ResultsThe multivariate logistic regression analysis was performed for the indices determined to be statistically significant by the univariate analysis, and the results showed that the prognostic factors were total bilirubin (TBil, prothrombin time activity (PTA, Na+, total cholesterol (TC, Child-Turcotte-Pugh (CTP score, age ≥50 years, the presence of liver cirrhosis, bilirubin-enzyme separation, and complications. The multivariate regression analysis was performed for the complications determined to affect prognosis by the univariate analysis, and the results showed that the complications as risk factors were hepatic encephalopathy, hepatorenal syndrome, and infection. ConclusionTBil, PTA, Na+, TC, CTP score, age ≥50 years, the presence of liver cirrhosis, bilirubin-enzyme separation, and complications are independent risk factors for the prognosis of patients with HBV-related acute-on-chronic liver failure. Liver failure patients with hepatic

  20. Development of biodegradable polycaprolactone film as an internal fixation material to enhance tendon repair: an in vitro study.

    Science.gov (United States)

    Hu, Jian-Zhong; Zhou, Yong-Chun; Huang, Li-Hua; Lu, Hong-Bin

    2013-08-19

    Current tendon repair techniques do not provide sufficient tensile strength at the repair site, and thus early active motion rehabilitation after tendon repair is discouraged. To enhance the post-operative tensile strength, we proposed and tested an internal fixation technique using a polycaprolactone (PCL) biofilm. PCL was chosen for its good biocompatibility, excellent mechanical strength, and an appropriate degradation time scale. PCL biofilms were prepared by a modified melt-molding/leaching technique, and the physical and mechanical properties and in vitro degradation rate were assessed. The pore size distribution of the biofilm and the paratenon of native tendons were observed using scanning electron microscopy. Next, we determined whether this biofilm could enhance the tensile strength of repaired tendons. We performed tensile tests on rabbit Achilles tendons that were first lacerated and then repaired: 1) using modified Kessler suture combined with running peripheral suture ('control' group), or 2) using biofilm to wrap the tendon and then fixation with sutures ('biofilm' group). The influence of different repair techniques on tendon tensile strength was evaluated by mechanical testing. The novel biofilm had supple texture and a smooth surface. The mean thickness of the biofilm was 0.25 mm. The mean porosity of the biofilm was 45.3%. The paratenon of the rabbit Achilles tendon had pores with diameters ranging from 1 to 9 μm, which were similar to the 4-12 μm diameter pores in the biofilm cross-section. The weight loss of the biofilms at 4 weeks was only 0.07%. The molecular weight of PCL biofilms did not change after immersion in phosphate buffered saline for 4 weeks. The failure loads of the biofilm were similar before (48 ± 9 N) and after immersion (47 ± 7 N, P > 0.1). The biofilm group had ~70% higher mean failure loads and 93% higher stiffness compared with the control group. We proposed and tested an internal fixation technique

  1. Predicting Eye Fixations on Complex Visual Stimuli Using Local Symmetry.

    Science.gov (United States)

    Kootstra, Gert; de Boer, Bart; Schomaker, Lambert R B

    2011-03-01

    Most bottom-up models that predict human eye fixations are based on contrast features. The saliency model of Itti, Koch and Niebur is an example of such contrast-saliency models. Although the model has been successfully compared to human eye fixations, we show that it lacks preciseness in the prediction of fixations on mirror-symmetrical forms. The contrast model gives high response at the borders, whereas human observers consistently look at the symmetrical center of these forms. We propose a saliency model that predicts eye fixations using local mirror symmetry. To test the model, we performed an eye-tracking experiment with participants viewing complex photographic images and compared the data with our symmetry model and the contrast model. The results show that our symmetry model predicts human eye fixations significantly better on a wide variety of images including many that are not selected for their symmetrical content. Moreover, our results show that especially early fixations are on highly symmetrical areas of the images. We conclude that symmetry is a strong predictor of human eye fixations and that it can be used as a predictor of the order of fixation.

  2. Complications are reduced with a protocol to standardize timing of fixation based on response to resuscitation.

    Science.gov (United States)

    Vallier, Heather A; Moore, Timothy A; Como, John J; Wilczewski, Patricia A; Steinmetz, Michael P; Wagner, Karl G; Smith, Charles E; Wang, Xiao-Feng; Dolenc, Andrea J

    2015-10-01

    Our group developed a protocol, entitled Early Appropriate Care (EAC), to determine timing of definitive fracture fixation based on presence and severity of metabolic acidosis. We hypothesized that utilization of EAC would result in fewer complications than a historical cohort and that EAC patients with definitive fixation within 36 h would have fewer complications than those treated at a later time. Three hundred thirty-five patients with mean age 39.2 years and mean Injury Severity Score (ISS) 26.9 and 380 fractures of the femur (n = 173), pelvic ring (n = 71), acetabulum (n = 57), and/or spine (n = 79) were prospectively evaluated. The EAC protocol recommended definitive fixation within 36 h if lactate <4.0 mmol/L, pH ≥7.25, or base excess (BE) ≥-5.5 mmol/L. Complications including infections, sepsis, DVT, organ failure, pneumonia, acute respiratory distress syndrome (ARDS), and pulmonary embolism (PE) were identified and compared for early and delayed patients and with a historical cohort. All 335 patients achieved the desired level of resuscitation within 36 h of injury. Two hundred sixty-nine (80%) were treated within 36 h, and 66 had protocol violations, treated on a delayed basis, due to surgeon choice in 71%. Complications occurred in 16.3% of patients fixed within 36 h and in 33.3% of delayed patients (p = 0.0009). Hospital and ICU stays were shorter in the early group: 9.5 versus 17.3 days and 4.4 versus 11.6 days, respectively, both p < 0.0001. This group of patients when compared with a historical cohort of 1443 similar patients with 1745 fractures had fewer complications (16.3 versus 22.1%, p = 0.017) and shorter length of stay (LOS) (p = 0.018). Our EAC protocol recommends definitive fixation within 36 h in resuscitated patients. Early fixation was associated with fewer complications and shorter LOS. The EAC recommendations are safe and effective for the majority of severely injured patients with mechanically

  3. [Prognostic factors related to non surgical treatment failure of splenic injuries in the abdominal blunt trauma].

    Science.gov (United States)

    Carvalho, Fábio Henrique de; Romeiro, Paula Christina Marra; Collaço, Iwan Augusto; Baretta, Giorgio Alfredo Pedroso; Freitas, Alexandre Coutinho Teixeira de; Matias, Jorge Eduardo Fouto

    2009-04-01

    Identify prognostic factors related to treatment failure of blunt splenic injuries managed by non surgical treatment (NST). Fifty six adult patients submitted to NST were prospectively studied. The injuries were diagnosed by computed axial tomography scan and classified according to AAST (American Association for Surgery of Trauma) criteria. Patients were divided in success and failure groups. NST failure was defined as the need for laparotomy for any reason. NST failures (19.6%) were due to: abdominal pain (45.4%), hemodinamic instability (36.4%), splenic haematoma associated to a fall in hematocrit (9.1%) and splenic abscess (9.1%). There were no failures in grade I and II of the splenic injuries; failure rate was 17.5% in grade III and IV injuries grouped, and 80% in grade V injuries (p = 0,0008). In the success group, 31.3% patients received red cell transfusions, versus 63.6% patients in the failure group (p = 0,05). Failure rate in patients with ISS = 8 was zero; 15.9% in patients with ISS 9 to 25; and 50% in patients with ISS = 26 (p = 0,05). There were no deaths or missed bowel injuries. ISS and splenic injury grade were related to failure of NST.

  4. Application of monorail fixator for femoral gap nonunion

    Directory of Open Access Journals (Sweden)

    Agrawal Hemendra Kumar

    2014-07-01

    Full Text Available 【Abstract】Difficult femoral nonunion takes account of infective nonunion and aseptic gap nonunion. Limb length discrepancy and nonunion need to be tackled simultaneously. Conventionally Ilizarov ring fixator is in vogue but it has some limitations. To overcome these, monorail fixator is an effective alternative. Persistent good results can be obtained if we can get a perfect anatomical alignment and good regeneration. Key words: Femur; Ilizarov technique; External fixators

  5. A failure of suppression within the default mode network in depressed adolescents with compulsive internet game play.

    Science.gov (United States)

    Han, Doug Hyun; Kim, Sun Mi; Bae, Sujin; Renshaw, Perry F; Anderson, Jeffrey S

    2016-04-01

    Individuals who are chronic, compulsive video game players experience an elevated incidence of major depression. Excessive or problematic game play can interact with depression clinically, and may magnify impulsive behavior associated with video gaming. Functional brain imaging was performed during a Wisconsin Card Sorting Test (WCST) task in 42 healthy control and 95 volunteers seeking treatment for compulsive video game playing, including 60 participants without major depression (pure internet gaming disorder, pure IGD) and 35 participants comorbid with major depression (IGD+MDD). In response to the WCST in contrast to fixation, activation was observed in canonical brain attentional networks including bilateral intraparietal sulcus, frontal eye fields, and middle temporal cortical regions as well as dorsolateral prefrontal, inferior parietal and anterior insula, anterior cingulate cortex in all participants. For WCST>Fixation contrasts, the IGD+MDD group exhibited greater relative activation within the left hippocampus, compared to healthy control participants. For WCST>Fixation contrasts, the IGD+MDD group exhibited greater relative activation within the left hippocampus and the right parahippocampal gyrus immediately posterior to the hippocampus, compared to the pure IGD group. In cohorts of individuals with a history of compulsive internet game play, individuals with depression showed failure to suppress default mode network activity during an attentionally demanding task, compared to individuals without depression, including comparison groups with and without a history of compulsive video gaming. This reduced suppression of the brain regions within the default mode network may be a consequence of depressive neurophysiology or represent a predisposition for depression within compulsive game players. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. 14CO2 fixation pattern of cyanobacteria

    International Nuclear Information System (INIS)

    Erdmann, N.; Schiewer, U.

    1985-01-01

    The 14 CO 2 fixation pattern of three cyanobacteria in the light and dark were studied. Two different chromatographic methods widely used for separating labelled photosynthetic intermediates were compared. After ethanolic extraction, a rather uniform fixation pattern reflecting mainly the β-carboxylation pathway is obtained for all 3 species. Of the intermediates, glucosylglycerol is specific and high citrulline and low malate contents are fairly specific to cyanobacteria. The composition of the 14 CO 2 fixation pattern is hardly affected by changes in temperature or light intensity, but it is severely affected by changes in the water potential of the medium. (author)

  7. Acromioclavicular joint dislocation: a Dog Bone button fixation alone versus Dog Bone button fixation augmented with acromioclavicular repair-a finite element analysis study.

    Science.gov (United States)

    Sumanont, Sermsak; Nopamassiri, Supachoke; Boonrod, Artit; Apiwatanakul, Punyawat; Boonrod, Arunnit; Phornphutkul, Chanakarn

    2018-03-20

    Suspension suture button fixation was frequently used to treat acromioclavicular joint (ACJ) dislocation. However, there were many studies reporting about complications and residual horizontal instability after fixation. Our study compared the stability of ACJ after fixation between coracoclavicular (CC) fixation alone and CC fixation combined with ACJ repair by using finite element analysis (FEA). A finite element model was created by using CT images from the normal shoulder. The model 1 was CC fixation with suture button alone, and the model 2 was CC fixation with suture button combined with ACJ repair. Three different forces (50, 100, 200 N) applied to the model in three planes; inferior, anterior and posterior direction load to the acromion. The von Mises stress of the implants and deformation at ACJs was recorded. The ACJ repair in the model 2 could reduce the peak stress on the implant after applying the loading forces to the acromion which the ACJ repair could reduce the peak stress of the FiberWire at suture button about 90% when compared to model 1. And, the ACJ repair could reduce the deformation of the ACJ after applying the loading forces to the acromion in both vertical and horizontal planes. This FEA supports that the high-grade injuries of the ACJ should be treated with CC fixation combined with ACJ repair because this technique provides excellent stability in both vertical and horizontal planes and reduces stress to the suture button.

  8. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    Science.gov (United States)

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  9. "Cold" Fixation: Reconciliation of Nitrogen Fixation Rates and Diazotroph Assemblages in the Arctic Ocean

    Science.gov (United States)

    Fong, A. A.; Waite, A.; Rost, B.; Richter, K. U.

    2016-02-01

    Measurements of biological nitrogen fixation are typically conducted in oligotrophic subtropical and tropical marine environments where concentrations of fixed inorganic nitrogen are low. To date, only a handful of nitrogen fixation studies have been conducted in high latitude marine environments, but further investigation is needed to resolve the distribution of cold ocean diazotrophic assemblages. Nitrogen fixation rates and nifH gene distributions were measured at seven stations from 5°E to 20°E, north of 81°N in the Arctic Ocean at the onset of summer 2015. Discrete water samples in ice-covered regions were collected from the sea surface to 200 m for 15N2-tracer additions and targeted nifH gene and transcript analyses. Previous work suggests that heterotrophic bacteria dominate diazotrophic communities in the Arctic Ocean. Therefore, additional nifH gene surveys of sinking particles were conducted to test for enrichment on organic matter-rich microenvironments. Together, these measurements aim to reconcile diazotrophic activity with microbial community composition, further elucidating how nitrogen fixers could impact current concepts in polar carbon and nutrient cycling.

  10. 123I-meta-iodo-benzyl-guanidine myocardial scintigraphy and congestive heart failure: current data and perspective

    International Nuclear Information System (INIS)

    Agostini, D.; Darlas, Y.; Quennelle, F.; Bouvard, G.; Scanu, P.; Grollier, G.; Potier, J.C.; Babatasi, G.; Belin, A.

    1997-01-01

    Congestive heart failure is often associated with an impairment of the sympathetic nervous system, i.e., global hyperactivity and regional impairment of the adrenergic system. Cardiac 123 I-MIBG scintigraphy is a radionuclide technique which can explore the presynaptic adrenergic function. Myocardial MIBG fixation is decreased in congestive heart failure, reflecting a reduction of norepinephrine uptake by the myocardial presynaptic nerve endings. The impairment of presynaptic function occurs early in the disease and is actually involved in the pathogenesis of cardiac failure. Cardiac MIBG scintigraphy is a useful tool to explore the myocardial adrenergic stores in patients with congestive heart failure. It could be proposed in patients with severe ventricular dysfunction in order to assist physicians in setting-up the timing of heart transplantation. (authors)

  11. Comparative study of thyroid fixation of different iodine compounds; Etude comparative de la fixation thyroidienne de differents composes iodes

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, R; Coeur, A; Raynfeld, Ch [Commissariat a l' Energie Atomique, Grenoble (France).Centre d' Etudes Nucleaires

    1961-07-01

    The aim of this work is to study the thyroid fixation of various iodine compounds in mineral or organic form. The animals (rats) are given therapeutic doses of the derivative orally with the object of saturating the thyroid, and then receive a determined dose of radio-iodine 131 by intra-peritoneal injection; any fixation of this latter is then measured under anaesthetic by means of a scintillation counter. Whatever form of iodine derivative was used whether in ionic (potassium iodide type) or organic form (iodo-tannic syrup) or in the form of elementary iodine (iodinated water), thyroid saturation was always obtained, as shown by practically zero fixation of the 4 {mu}curies of iodine 131 administered by intra-peritoneal injection. (author) [French] Notre travail a pour but l'etude de la fixation thyroidienne de differents composes iodes sous forme minerale ou organique. Les animaux (rats), apres absorption orale de doses therapeutiques de derives destines a saturer leur thyroide recoivent par voie intra-peritoneale une dose determinee de radio-iode {sup 131}I, la fixation eventuelle de ce dernier est ensuite mesuree sous anesthesie en utilisant un compteur a scintillation. Quelle que soit la forme utilisee, c'est-a-dire derive iode sous forme ionique (type iodure de potassium) ou sous forme organique (sirop iodotanique) ou encore sous forme d'iode metalloidique (eau iodee), nous avons obtenu chaque fois une saturation thyroidienne mise en evidence par une fixation pratiquement nulle des 4 {mu}curies de l'iode 131 injectes par voie intraperitoneale. (auteur)

  12. A cell shrinkage artefact in growth plate chondrocytes with common fixative solutions: importance of fixative osmolarity for maintaining morphology

    Directory of Open Access Journals (Sweden)

    MY Loqman

    2010-05-01

    Full Text Available The remarkable increase in chondrocyte volume is a major determinant in the longitudinal growth of mammalian bones. To permit a detailed morphological study of hypertrophic chondrocytes using standard histological techniques, the preservation of normal chondrocyte morphology is essential. We noticed that during fixation of growth plates with conventional fixative solutions, there was a marked morphological (shrinkage artifact, and we postulated that this arose from the hyper-osmotic nature of these solutions. To test this, we fixed proximal tibia growth plates of 7-day-old rat bones in either (a paraformaldehyde (PFA; 4%, (b glutaraldehyde (GA; 2% with PFA (2% with ruthenium hexamine trichloride (RHT; 0.7%, (c GA (2% with RHT (0.7%, or (d GA (1.3% with RHT (0.5% and osmolarity adjusted to a ‘physiological’ level of ~280mOsm. Using conventional histological methods, confocal microscopy, and image analysis on fluorescently-labelled fixed and living chondrocytes, we then quantified the extent of cell shrinkage and volume change. Our data showed that the high osmolarity of conventional fixatives caused a shrinkage artefact to chondrocytes. This was particularly evident when whole bones were fixed, but could be markedly reduced if bones were sagittally bisected prior to fixation. The shrinkage artefact could be avoided by adjusting the osmolarity of the fixatives to the osmotic pressure of normal extracellular fluids (~280mOsm. These results emphasize the importance of fixative osmolarity, in order to accurately preserve the normal volume/morphology of cells within tissues.

  13. Biomechanical analysis of titanium fixation plates and screws in ...

    African Journals Online (AJOL)

    2015-08-10

    Aug 10, 2015 ... values on fixative appliances were predicted by means of. 3D FEA. The highest ... such as poor resistance to torsional forces, poor rigidity, and poor stability in ... the adequacy of mathematical models to relate mechanical factors such as ... the risk of bacterial contamination, scarring, postoperative edema ...

  14. Clinical efficacy and safety of limited internal fixation combined with external fixation for Pilon fracture: A systematic review and meta-analysis

    OpenAIRE

    Zhang, Shaobo; Zhang, Yibao; Wang, Shenghong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing

    2017-01-01

    Purpose: To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. Methods: We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the ...

  15. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    Science.gov (United States)

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  16. Bridging suture makes consistent and secure fixation in double-row rotator cuff repair.

    Science.gov (United States)

    Fukuhara, Tetsutaro; Mihata, Teruhisa; Jun, Bong Jae; Neo, Masashi

    2017-09-01

    Inconsistent tension distribution may decrease the biomechanical properties of the rotator cuff tendon after double-row repair, resulting in repair failure. The purpose of this study was to compare the tension distribution along the repaired rotator cuff tendon among three double-row repair techniques. In each of 42 fresh-frozen porcine shoulders, a simulated infraspinatus tendon tear was repaired by using 1 of 3 double-row techniques: (1) conventional double-row repair (no bridging suture); (2) transosseous-equivalent repair (bridging suture alone); and (3) compression double-row repair (which combined conventional double-row and bridging sutures). Each specimen underwent cyclic testing at a simulated shoulder abduction angle of 0° or 40° on a material-testing machine. Gap formation and tendon strain were measured during the 1st and 30th cycles. To evaluate tension distribution after cuff repair, difference in gap and tendon strain between the superior and inferior fixations was compared among three double-row techniques. At an abduction angle of 0°, gap formation after either transosseous-equivalent or compression double-row repair was significantly less than that after conventional double-row repair (p row repair (p = 0.01) at 0° abduction had significantly less difference in gap formation between the superior and inferior fixations than did conventional double-row repair. After the 30th cycle, the difference in longitudinal strain between the superior and inferior fixations at 0° abduction was significantly less with compression double-row repair (2.7% ± 2.4%) than with conventional double-row repair (8.6% ± 5.5%, p = 0.03). Bridging sutures facilitate consistent and secure fixation in double-row rotator cuff repairs, suggesting that bridging sutures may be beneficial for distributing tension equally among all sutures during double-row repair of rotator cuff tears. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B

  17. The use of titanium and stainless steel in fracture fixation.

    Science.gov (United States)

    Hayes, J S; Richards, R G

    2010-11-01

    The use of metal in fracture fixation has demonstrated unrivalled success for many years owing to its high stiffness, strength, biological toleration and overall reliable function. The most prominent materials used are electropolished stainless steel and commercially pure titanium, along with the more recent emergence of titanium alloys. Despite the many differences between electropolished stainless steel and titanium, both materials provide a relatively predictable clinical outcome, and offer similar success for fulfilling the main biomechanical and biological requirements of fracture fixation despite distinctive differences in implant properties and biological responses. This article explores these differences by highlighting the limitations and advantages of both materials, and addresses how this translates to clinical success.

  18. Miniplate fixation of Le Fort I osteotomies.

    Science.gov (United States)

    Rosen, H M

    1986-12-01

    The use of rigid, internal, three-dimensional fixation using vitallium bone plates in 28 consecutive Le Fort I osteotomies is presented. A minimum follow-up period of 6 months was required for inclusion in this patient group. Maxillary movements included advancements (17), intrusions (9), lengthenings (5), and retrusions (2). The majority of maxillae were moved in more than one plane of space. Technical details, complications, and relapse potential are discussed. Advantages of rigid plate fixation include marked reductions in the length of intermaxillary fixation with light training elastics only. Immediate postoperative airway problems are thereby eliminated. Six months of follow-up would appear to indicate a low potential for osseous relapse when compared to wire osteosynthesis, regardless of the direction of maxillary movement. The major disadvantage is the decreased ability of postoperative orthodontics to move dento-osseous segments if skeletal occlusal disharmony persists postoperatively. For this reason, close attention to preoperative planning and operative technique is critical for the success of this fixation method.

  19. 14CO2-fixation and nitrate reductase activity in vivo in relation to hybrid vigour in maize

    International Nuclear Information System (INIS)

    Balasubramanian, V.; Shanthakumari, P.; Sinha, S.K.

    1977-01-01

    Dry matter accumulation in maize shoots, leaf area, 14 CO 2 -fixation and nitrate reductase activity in vivo were measured in the field grown heterotic hybrid CM 400x CM 300 and its inbred parents CM 300 and CM 400 from seedling to maturity. Rates of dry matter accumulation and leaf area development were higher in the hybrid during the initial vegetative phase than in the inbreds. The hybrid had more absolute level of 14 CO 2 -fixation and nitrate reductase activity, although the rates of these processes on unit weight basis were not higher than those of inbreds. It is concluded that the rapid development of leaf area in hybrids during the early stages of vegetative growth is probably important for hybrid vigour. (author)

  20. Brucellosis seroprevalence in Bali cattle with reproductive failure in South Sulawesi and Brucella abortus biovar 1 genotypes in the Eastern Indonesian archipelago.

    Science.gov (United States)

    Muflihanah, Hanah; Hatta, Mochammad; Rood, Ente; Scheelbeek, Pauline; Abdoel, Theresia H; Smits, Henk L

    2013-11-26

    Brucellosis is a major cause of infertility and reproductive failure in livestock. While cattle in the Eastern Indonesian archipelago suffers from reproductive problems information on bovine brucellosis in the region is fragmentary. The control of brucellosis requires a major and prolonged effort and confirmation of the infection by isolation with detailed knowledge of the spread of the infection is essential when planning a control program. Serological investigation of Brucella infection in beef cattle tended under extensive farming conditions revealed a high seroprevalence (19.3%; 95% CI, 17-22) in the compliment fixation tests. The results of a rapid and simple field test correlated well with the Rose Bengal test (kappa, 0.917) and indicated an acceptable sensitivity (87.5%) and specificity (98.1%) compared with the complement fixation test. Reproductive failure was reported for 39.0% of the cows with a loss of calves due to abortion or early death amounting to 19.3%. Past reproductive failure did not, however, correlate with seropositivity in the complement fixation test (RP = 1.21; P = 0.847). B. abortus biovar 1 was freshly isolated from the hygromas of two cows and together with thirty banked isolates collected since 1990 from different parts of Sulawesi and Timor eight related genotypes could be distinguished with one genotype being identical to that of an isolate (BfR91) from Switzerland. The Indonesian genotypes formed together with BfR91 and one African and one North American isolate a distinct branch on the B. abortus biovar 1 dendogram. Bovine brucellosis appears to be widespread in the Eastern Indonesian archipelago and calls for urgent intervention. The fresh isolation of the pathogen together with the observed high seroprevalence demonstrates the presence and frequent exposure of cattle in the area to the pathogen. The application of a rapid and simple field test for brucellosis could be very useful for the quick screening of cattle at the pen side.

  1. Use of low enriched /sup 15/N/sub 2/ for symbiotic fixation tests

    Energy Technology Data Exchange (ETDEWEB)

    Victoria, R L

    1975-01-01

    Gaseous atmospheres containing /sup 15/N/sub 2/ with low enrichment were used to test symbiotic nitrogen fixation in beans (Phaseolus vulgari, L.). The tests of fixation in nodulated roots and the tests of fixation in the whole plant, in which the plants were placed inside a specially constructed growth chamber, gave positive results and suggest that the methodology used can be very helpfull in more detailed studies on symbiotic fixation. Samples of atmospheric air were purified by absorption of O/sub 2/ and CO/sub 2/ by two methods. The purified N/sub 2/ obtained was analysed and the results were compared. Samples of bean plant material were collected in natural conditions and analysed for /sup 15/N natural variation. Several samples were prepared for /sup 15/N isotopic analysis by two methods. The results obtained were compared. All samples were analysed in an Atlas-Varian Ch-4 model mass spectrometer, and the results were given in delta /sup 15/N/sub 0///sup 00/ variation in relation to a standard gas.

  2. Fixation orientation in ankle fractures with syndesmosis injury.

    Science.gov (United States)

    Nimick, Craig J; Collman, David R; Lagaay, Pieter

    2013-01-01

    Accurate reduction of the syndesmosis has been shown to be an important prognostic factor for functional outcome in ankle injuries that disrupt the syndesmosis. The purpose of the present case series was to assess the fixation orientation and the position of the fibula within the tibial incisura after open reduction and internal fixation of ankle fractures with syndesmosis injury. Computed tomography was used to assess the accuracy of the reduction. Twelve patients were included in the present case series. A ratio representing the relationship between the tibia and fibula and the orientation of the syndesmotic fixation was measured preoperatively and postoperatively and compared with the uninjured contralateral ankle, representing the patient's normal anatomy. The measurements were accomplished electronically to one tenth of 1 mm using Stentor Intelligent Informatics, I-site, version 3.3.1 (Phillips Electronics; Andover, MA). Posteriorly oriented syndesmotic fixation caused posterior translation of the fibula with respect to the tibia and anteriorly oriented syndesmotic fixation caused anterior translation. Copyright © 2013. Published by Elsevier Inc.

  3. Hemodynamic changes during weaning: can we assess and predict cardiac-related weaning failure by transthoracic echocardiography?

    Science.gov (United States)

    Voga, Gorazd

    2010-01-01

    Cardiac-related failure of weaning from mechanical ventilation is an important reason for prolonged mechanical ventilation, intensive care unit treatment, and increased morbidity and mortality. When transthoracic echocardiography (TTE) is routinely performed before a weaning trial, patients at high risk of cardiac-related failure can be detected by low left ventricular (LV) ejection fraction, diastolic dysfunction, and elevated LV filling pressure. During the weaning trial, a further increase of LV filling pressure and progression of diastolic failure can be observed by repeated TTE. Owing to certain limitations concerning patients and methodology, TTE cannot be employed in every patient and invasive hemodynamic monitoring is still mandatory in selected patients with repetitive weaning failure.

  4. Computed tomography- and fluoroscopy-guided percutaneous screw fixation of low-grade isthmic spondylolisthesis in adults: a new technique

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Huwart, Laurent; Browaeys, Patrick; Nouri, Yasir; Ibba, Caroline; Hauger, Olivier; Marcy, Pierre-Yves; Boileau, Pascal

    2012-01-01

    To evaluate the feasibility of computed tomography (CT)- and fluoroscopy-guided percutaneous screw fixation for the treatment of low-grade isthmic spondylolisthesis in adults. Ten consecutive adult patients (four men and six women; mean age: 57.1 [range, 44-78 years]) were prospectively treated by percutaneous screw fixation for low-grade (six grade 1 and four grade 2) isthmic spondylolisthesis of L5. For each patient, two 4.0-mm Asnis III cannulated screws were placed to fix the pars interarticularis defects. All procedures were performed under local anaesthesia by using CT and fluoroscopy guidance. Post-operative outcome was assessed using the visual analogue scale and Oswestry Disability Index (ODI) scores. The procedure time ranged from 45 to 60 min. The mean screw length was 27 mm (range, 24-32 mm). The VAS and ODI measurements ± SD decreased from 7.8 ± 0.9 preoperatively to 1.5 ± 1.1 at the last 2-year follow-up, and from 62.3 ± 17.2 to 15.1 ± 6.0, respectively (P < 0.001 in both cases). Neither slip progression nor screw failure was noted. This feasibility study showed that CT- and fluoroscopy-guided percutaneous screw fixation could be a rapid, safe and effective method of treating low-grade isthmic spondylolisthesis. (orig.)

  5. Computed tomography- and fluoroscopy-guided percutaneous screw fixation of low-grade isthmic spondylolisthesis in adults: a new technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas; Huwart, Laurent; Browaeys, Patrick; Nouri, Yasir; Ibba, Caroline [Hopital Archet 2, Centre Hospitalo-Universitaire de Nice, Department of Radiology, Nice (France); Hauger, Olivier [Hopital Pellegrin, Centre Hospitalo-Universitaire de Bordeaux, Department of Radiology, Bordeaux (France); Marcy, Pierre-Yves [Antoine Lacassagne Cancer Research Institute, Department of Radiology, Nice (France); Boileau, Pascal [Hopital Archet 2, Centre Hospitalo-Universitaire de Nice, Department of Orthopedic Surgery, Nice (France)

    2012-12-15

    To evaluate the feasibility of computed tomography (CT)- and fluoroscopy-guided percutaneous screw fixation for the treatment of low-grade isthmic spondylolisthesis in adults. Ten consecutive adult patients (four men and six women; mean age: 57.1 [range, 44-78 years]) were prospectively treated by percutaneous screw fixation for low-grade (six grade 1 and four grade 2) isthmic spondylolisthesis of L5. For each patient, two 4.0-mm Asnis III cannulated screws were placed to fix the pars interarticularis defects. All procedures were performed under local anaesthesia by using CT and fluoroscopy guidance. Post-operative outcome was assessed using the visual analogue scale and Oswestry Disability Index (ODI) scores. The procedure time ranged from 45 to 60 min. The mean screw length was 27 mm (range, 24-32 mm). The VAS and ODI measurements {+-} SD decreased from 7.8 {+-} 0.9 preoperatively to 1.5 {+-} 1.1 at the last 2-year follow-up, and from 62.3 {+-} 17.2 to 15.1 {+-} 6.0, respectively (P < 0.001 in both cases). Neither slip progression nor screw failure was noted. This feasibility study showed that CT- and fluoroscopy-guided percutaneous screw fixation could be a rapid, safe and effective method of treating low-grade isthmic spondylolisthesis. (orig.)

  6. Measures and limits of models of fixation selection.

    Directory of Open Access Journals (Sweden)

    Niklas Wilming

    Full Text Available Models of fixation selection are a central tool in the quest to understand how the human mind selects relevant information. Using this tool in the evaluation of competing claims often requires comparing different models' relative performance in predicting eye movements. However, studies use a wide variety of performance measures with markedly different properties, which makes a comparison difficult. We make three main contributions to this line of research: First we argue for a set of desirable properties, review commonly used measures, and conclude that no single measure unites all desirable properties. However the area under the ROC curve (a classification measure and the KL-divergence (a distance measure of probability distributions combine many desirable properties and allow a meaningful comparison of critical model performance. We give an analytical proof of the linearity of the ROC measure with respect to averaging over subjects and demonstrate an appropriate correction of entropy-based measures like KL-divergence for small sample sizes in the context of eye-tracking data. Second, we provide a lower bound and an upper bound of these measures, based on image-independent properties of fixation data and between subject consistency respectively. Based on these bounds it is possible to give a reference frame to judge the predictive power of a model of fixation selection. We provide open-source python code to compute the reference frame. Third, we show that the upper, between subject consistency bound holds only for models that predict averages of subject populations. Departing from this we show that incorporating subject-specific viewing behavior can generate predictions which surpass that upper bound. Taken together, these findings lay out the required information that allow a well-founded judgment of the quality of any model of fixation selection and should therefore be reported when a new model is introduced.

  7. CO2 Fixation by Membrane Separated NaCl Electrolysis

    DEFF Research Database (Denmark)

    Park, Hyun Sic; Lee, Ju Sung; Han, Junyoung

    2015-01-01

    for converting CO2 into CaCO3 requires high temperature and high pressure as reaction conditions. This study proposes a method to fixate CaCO3 stably by using relatively less energy than existing methods. After forming NaOH absorbent solution through electrolysis of NaCl in seawater, CaCO3 was precipitated...... crystal product was high-purity calcite. The study shows a successful method for fixating CO2 by reducing carbon dioxide released into the atmosphere while forming high-purity CaCO3.......Atmospheric concentrations of carbon dioxide (CO2), a major cause of global warming, have been rising due to industrial development. Carbon capture and storage (CCS), which is regarded as the most effective way to reduce such atmospheric CO2 concentrations, has several environmental and technical...

  8. EFFECT OF EMBEDDING METHODS VERSUS FIXATIVE TYPE ON KARYOMETRIC MEASURES

    NARCIS (Netherlands)

    BOON, ME; VANDERPOEL, HG; TAN, CJA; KOK, LP

    The influence of fixation and embedding methods in seven urologic tumor samples was studied karyometrically for 12 preparatory techniques. Routine histologic formalin fixation was compared with Carbowax and Kryofix fixatives. Also, histologic material was studied embedded in paraffin and plastic

  9. Fracture healing using degradable magnesium fixation plates and screws.

    Science.gov (United States)

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles

    2015-02-01

    Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    Science.gov (United States)

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation

  11. Relocatable fixation systems in intracranial stereotactic radiotherapy. Accuracy of serial CT scans and patient acceptance in a randomized design.

    Science.gov (United States)

    Theelen, A; Martens, J; Bosmans, G; Houben, R; Jager, J J; Rutten, I; Lambin, P; Minken, A W; Baumert, B G

    2012-01-01

    The goal was to provide a quantitative evaluation of the accuracy of three different fixation systems for stereotactic radiotherapy and to evaluate patients' acceptance for all fixations. A total of 16 consecutive patients with brain tumours undergoing fractionated stereotactic radiotherapy (SCRT) were enrolled after informed consent (Clinical trials.gov: NCT00181350). Fixation systems evaluated were the BrainLAB® mask, with and without custom made bite-block (fixations S and A) and a homemade neck support with bite-block (fixation B) based on the BrainLAB® frame. The sequence of measurements was evaluated in a randomized manner with a cross-over design and patients' acceptance by a questionnaire. The mean three-dimensional (3D) displacement and standard deviations were 1.16 ± 0.68 mm for fixation S, 1.92 ± 1.28 and 1.70 ± 0.83 mm for fixations A and B, respectively. There was a significant improvement of the overall alignment (3D vector) when using the standard fixation instead of fixation A or B in the craniocaudal direction (p = 0.037). Rotational deviations were significantly less for the standard fixation S in relation to fixations A (p = 0.005) and B (p = 0.03). EPI imaging with off-line correction further improved reproducibility. Five out of 8 patients preferred the neck support with the bite-block. The mask fixation system in conjunction with a bite-block is the most accurate fixation for SCRT reducing craniocaudal and rotational movements. Patients favoured the more comfortable but less accurate neck support. To optimize the accuracy of SCRT, additional regular portal imaging is warranted.

  12. Relocatable fixation systems in intracranial stereotactic radiotherapy. Accuracy of serial CT scans and patient acceptance in a randomized design

    International Nuclear Information System (INIS)

    Theelen, A.; Martens, J.; Bosmans, G.; Houben, R.; Jager, J.J.; Rutten, I.; Lambin, P.; Baumert, B.G.; Minken, A.W.; Radiotherapeutic Inst. RISO, Deventer

    2012-01-01

    The goal was to provide a quantitative evaluation of the accuracy of three different fixation systems for stereotactic radiotherapy and to evaluate patients' acceptance for all fixations. Methods A total of 16 consecutive patients with brain tumours undergoing fractionated stereotactic radiotherapy (SCRT) were enrolled after informed consent (Clinical trials.gov: NCT00181350). Fixation systems evaluated were the BrainLAB registered mask, with and without custom made bite-block (fixations S and A) and a homemade neck support with bite-block (fixation B) based on the BrainLAB registered frame. The sequence of measurements was evaluated in a randomized manner with a cross-over design and patients' acceptance by a questionnaire. Results The mean three-dimensional (3D) displacement and standard deviations were 1.16 ± 0.68 mm for fixation S, 1.92 ± 1.28 and 1.70 ± 0.83 mm for fixations A and B, respectively. There was a significant improvement of the overall alignment (3D vector) when using the standard fixation instead of fixation A or B in the craniocaudal direction (p = 0.037). Rotational deviations were significantly less for the standard fixation S in relation to fixations A (p = 0.005) and B (p = 0.03). EPI imaging with off-line correction further improved reproducibility. Five out of 8 patients preferred the neck support with the bite-block. Conclusion The mask fixation system in conjunction with a bite-block is the most accurate fixation for SCRT reducing craniocaudal and rotational movements. Patients favoured the more comfortable but less accurate neck support. To optimize the accuracy of SCRT, additional regular portal imaging is warranted. (orig.)

  13. Hepatitis A related acute liver failure by consumption of contaminated food

    NARCIS (Netherlands)

    Chi, Heng; Haagsma, Elizabeth B.; Riezebos-Brilman, Annelies; van den Berg, Arie P.; Metselaar, Herold J.; de Knegt, Robert J.

    We present a patient with no medical history admitted for jaundice and dark coloured urine. Further investigations revealed hepatitis A related acute liver failure while the patient had no travel history, nor contact with infected individuals. After admission, the patient deteriorated fulfilling the

  14. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    Science.gov (United States)

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  15. A New Technique for Solving Tightrope Cutout during Acromioclavicular Joint Fixation: A Case Report

    Directory of Open Access Journals (Sweden)

    Ng BW

    2017-03-01

    Full Text Available Acromioclavicular joint (ACJ dissociation is one of the common injuries affecting adults. The stability of ACJ largely depends on the integrity of acromioclavicular ligament, coracoclavicular ligament, capsule, trapezius muscle and deltoid muscle. The injury has been classified by Rockwood into six types and treatment options can be guided by the classification. TightRope fixation is one of the many surgical procedures available to address acromioclavicular joint separation. It consists of tensioning of a no. 5 Fibrewire suture secured at both ends to low- profile metallic buttons. Despite various advantages of using this technique, complications such as suture cut-out, clavicle fracture and suture failure have been documented. The author presents a case of a type III acromioclavicular joint dissociation treated with TightRope which suture cutout was noted intra-operatively. Decision to amend the fixation using a cut one-third tubular plate as an additional anchor for the metallic button on the clavicle was made. Patient’s progress was evaluated using the University of California at Los Angeles Shoulder Score (UCLA Shoulder Score and significant improvement was noted six months post operatively. We propose this technique as a solution to the encountered problem.

  16. Carbon Dioxide Fixation in Isolated Kalanchoe Chloroplasts 1

    Science.gov (United States)

    Levi, Carolyn; Gibbs, Martin

    1975-01-01

    Chloroplasts isolated from Kalanchoe diagremontiana leaves were capable of photosynthesizing at a rate of 5.4 μmoles of CO2 per milligram of chlorophyll per hour. The dark rate of fixation was about 1% of the light rate. A high photosynthetic rate was associated with low starch content of the leaves. Ribose 5-phosphate, fructose 1,6-diphosphate, and dithiothreitol stimulated fixation, whereas phosphoenolpyruvate and azide were inhibitors. The products of CO2 fixation were primarily those of the photosynthetic carbon reduction cycle. PMID:16659249

  17. Changes in biomolecular profile in a single nucleolus during cell fixation.

    Science.gov (United States)

    Kuzmin, Andrey N; Pliss, Artem; Prasad, Paras N

    2014-11-04

    Fixation of biological sample is an essential technique applied in order to "freeze" in time the intracellular molecular content. However, fixation induces changes of the cellular molecular structure, which mask physiological distribution of biomolecules and bias interpretation of results. Accurate, sensitive, and comprehensive characterization of changes in biomolecular composition, occurring during fixation, is crucial for proper analysis of experimental data. Here we apply biomolecular component analysis for Raman spectra measured in the same nucleoli of HeLa cells before and after fixation by either formaldehyde solution or by chilled ethanol. It is found that fixation in formaldehyde does not strongly affect the Raman spectra of nucleolar biomolecular components, but may significantly decrease the nucleolar RNA concentration. At the same time, ethanol fixation leads to a proportional increase (up to 40%) in concentrations of nucleolar proteins and RNA, most likely due to cell shrinkage occurring in the presence of coagulant fixative. Ethanol fixation also triggers changes in composition of nucleolar proteome, as indicated by an overall reduction of the α-helical structure of proteins and increase in the concentration of proteins containing the β-sheet conformation. We conclude that cross-linking fixation is a more appropriate protocol for mapping of proteins in situ. At the same time, ethanol fixation is preferential for studies of RNA-containing macromolecules. We supplemented our quantitative Raman spectroscopic measurements with mapping of the protein and lipid macromolecular groups in live and fixed cells using coherent anti-Stokes Raman scattering nonlinear optical imaging.

  18. PIRCHE-II Is Related to Graft Failure after Kidney Transplantation

    Science.gov (United States)

    Geneugelijk, Kirsten; Niemann, Matthias; Drylewicz, Julia; van Zuilen, Arjan D.; Joosten, Irma; Allebes, Wil A.; van der Meer, Arnold; Hilbrands, Luuk B.; Baas, Marije C.; Hack, C. Erik; van Reekum, Franka E.; Verhaar, Marianne C.; Kamburova, Elena G.; Bots, Michiel L.; Seelen, Marc A. J.; Sanders, Jan Stephan; Hepkema, Bouke G.; Lambeck, Annechien J.; Bungener, Laura B.; Roozendaal, Caroline; Tilanus, Marcel G. J.; Vanderlocht, Joris; Voorter, Christien E.; Wieten, Lotte; van Duijnhoven, Elly M.; Gelens, Mariëlle; Christiaans, Maarten H. L.; van Ittersum, Frans J.; Nurmohamed, Azam; Lardy, Junior N. M.; Swelsen, Wendy; van der Pant, Karlijn A.; van der Weerd, Neelke C.; ten Berge, Ineke J. M.; Bemelman, Fréderike J.; Hoitsma, Andries; van der Boog, Paul J. M.; de Fijter, Johan W.; Betjes, Michiel G. H.; Heidt, Sebastiaan; Roelen, Dave L.; Claas, Frans H.; Otten, Henny G.; Spierings, Eric

    2018-01-01

    Individual HLA mismatches may differentially impact graft survival after kidney transplantation. Therefore, there is a need for a reliable tool to define permissible HLA mismatches in kidney transplantation. We previously demonstrated that donor-derived Predicted Indirectly ReCognizable HLA Epitopes presented by recipient HLA class II (PIRCHE-II) play a role in de novo donor-specific HLA antibodies formation after kidney transplantation. In the present Dutch multi-center study, we evaluated the possible association between PIRCHE-II and kidney graft failure in 2,918 donor–recipient couples that were transplanted between 1995 and 2005. For these donors–recipients couples, PIRCHE-II numbers were related to graft survival in univariate and multivariable analyses. Adjusted for confounders, the natural logarithm of PIRCHE-II was associated with a higher risk for graft failure [hazard ratio (HR): 1.13, 95% CI: 1.04–1.23, p = 0.003]. When analyzing a subgroup of patients who had their first transplantation, the HR of graft failure for ln(PIRCHE-II) was higher compared with the overall cohort (HR: 1.22, 95% CI: 1.10–1.34, p < 0.001). PIRCHE-II demonstrated both early and late effects on graft failure in this subgroup. These data suggest that the PIRCHE-II may impact graft survival after kidney transplantation. Inclusion of PIRCHE-II in donor-selection criteria may eventually lead to an improved kidney graft survival. PMID:29556227

  19. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Design and Optimization of Resorbable Silk Internal Fixation Devices

    Science.gov (United States)

    Haas, Dylan S.

    Limitations of current material options for internal fracture fixation devices have resulted in a large gap between user needs and hardware function. Metal systems offer robust mechanical strength and ease of implantation but require secondary surgery for removal and/or result in long-term complications (infection, palpability, sensitivity, etc.). Current resorbable devices eliminate the need for second surgery and long-term complications but are still associated with negative host response as well as limited functionality and more difficult implantation. There is a definitive need for orthopedic hardware that is mechanically capable of immediate fracture stabilization and fracture fixation during healing, can safely biodegrade while allowing complete bone remodeling, can be resterilized for reuse, and is easily implantable (self-tapping). Previous work investigated the use of silk protein to produce resorbable orthopedic hardware for non- load bearing fracture fixation. In this study, silk orthopedic hardware was further investigated and optimized in order to better understand the ability of silk as a fracture fixation system and more closely meet the unfulfilled market needs. Solvent-based and aqueous-based silk processing formulations were cross-linked with methanol to induce beta sheet structure, dried, autoclaved and then machined to the desired device/geometry. Silk hardware was evaluated for dry, hydrated and fatigued (cyclic) mechanical properties, in vitro degradation, resterilization, functionalization with osteoinductive molecules and implantation technique for fracture fixation. Mechanical strength showed minor improvements from previous results, but remains comparable to current resorbable fixation systems with the advantages of self-tapping ability for ease of implantation, full degradation in 10 months, ability to be resterilized and reused, and ability to release molecules for osteoinudction. In vivo assessment confirmed biocompatibility, showed

  1. Sacroiliac Screw Fixation

    NARCIS (Netherlands)

    E.W. van den Bosch

    2003-01-01

    textabstractThe aim of this thesis is to evaluate three major aspects of the use of sacroiliac screws in patients with unstable pelvic ring fractures: the optimal technique for sacroiliac screw fixation, the reliability of peroperative fluoroscopy and the late results. We focused on the questions

  2. Dinitrogen Fixation Within and Adjacent to Oxygen Deficient Waters of the Eastern Tropical South Pacific Ocean

    Science.gov (United States)

    Widner, B.; Mulholland, M. R.; Bernhardt, P. W.; Chang, B. X.; Jayakumar, A.

    2016-02-01

    Recent work suggests that planktonic diazotrophs are geographically more widely distributed than previously thought including relatively warm (14-23oC) aphotic oxygenated pelagic waters and in aphotic waters within oxygen deficient zones. Because the volume of aphotic water in the ocean is large and may increase in the future, if dinitrogen (N2) fixation is widely occurring at sub-euphotic depths, this could result in a dramatic upward revision of global nitrogen (N) inputs via this process. N2 fixation rates were measured during a cruise in the Eastern Tropical South Pacific using stable isotope tracer techniques that account for slow gas dissolution. Results are compared with light, nutrient, and oxygen gradients (and necessarily temperature gradients). In addition, rates of N2 fixation made in vertical profiles within and above oxygen deficient waters are compared with those measured in vertical profiles adjacent to oxygen deficient waters. Results suggest that while rates of N2 fixation were measurable in deeper anoxic waters, volumetric N2 fixation rates were higher in surface waters.

  3. Nitrogen fixation by legumes in retorted shale

    Energy Technology Data Exchange (ETDEWEB)

    Hersman, L E; Molitoris, E; Klein, D A

    1981-01-01

    A study was made to determine whether retorted shale additions would significantly affect symbiotic N/sub 2/ fixation. Results indicate that small additions of the shale may stimulate plant growth but with higher concentrations plants are stressed, resulting in a decreased biomass and a compensatory effect of an increased number of nodules and N/sub 2/ fixation potential. (JMT)

  4. Improper tube fixation causing a leaky cuff

    Directory of Open Access Journals (Sweden)

    Gupta Babita

    2010-01-01

    Full Text Available Leaking endotracheal tube cuffs are common problems in intensive care units. We report a case wherein the inflation tube was damaged by the adhesive plaster used for tube fixation and resulted in leaking endotracheal tube cuff. We also give some suggestions regarding the tube fixation and some remedial measures for damaged inflation system.

  5. Stable Fixation of a Cementless, Proximally Coated, Double Wedged, Double Tapered Femoral Stem in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Rolfson, Ola; Rubash, Harry E

    2016-01-01

    BACKGROUND: The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs). METHODS: Forty-seven patients (51 hips...... year remain stable at 5 years. RSA was the most sensitive method of detection for stems at greater risk for potential future failure. This report adds contributions to the positive results associated with this type of fixation. The results at 5 years showed excellent midterm survivorship in this cohort...

  6. External fixation of tibial pilon fractures and fracture healing.

    Science.gov (United States)

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  7. Medial Calcar Support and Radiographic Outcomes of Plate Fixation for Proximal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Shih-Jie Lin

    2015-01-01

    Full Text Available Plate fixation remains one of the most popular surgical procedures for treating proximal humeral fractures (PHFx; however, substantial rates of complications have been reported in the literature. The objectives of the study were to examine how medial calcar support (MCS affects the radiographic outcomes and to determine the prognostic factors predicting treatment failure. We performed a retrospective cohort study of 89 adult patients who had PHFx and were treated with plate fixation at our institution in 2007–2011. The enrolled patients were separated into two groups according to disruption of medial calcar. Our results revealed an increased rate of poor radiographic outcomes in patients with disrupted medial calcar. Osteonecrosis of the humeral head and redisplacement were the two radiographic outcomes which had a positive causality with disruption of medial calcar (P=0.008 and 0.050, resp.. Deficient medial calcar, inadequate reduction, diabetes mellitus, chronic kidney disease, and chronic liver disease were all significant predictors for the development of osteonecrosis in patients after PHFx surgery. Inadequate reduction was also a predictor for redisplacement. We confirmed that the restoration of medial calcar as well as comorbid conditions plays key roles in treatment of patients having PHFx with disrupted medial calcar.

  8. [Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton's fracture].

    Science.gov (United States)

    Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you

    2015-06-01

    To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation

  9. The Relationship Between Problem Size and Fixation Patterns During Addition, Subtraction, Multiplication, and Division

    Directory of Open Access Journals (Sweden)

    Evan T. Curtis

    2016-08-01

    Full Text Available Eye-tracking methods have only rarely been used to examine the online cognitive processing that occurs during mental arithmetic on simple arithmetic problems, that is, addition and multiplication problems with single-digit operands (e.g., operands 2 through 9; 2 + 3, 6 x 8 and the inverse subtraction and division problems (e.g., 5 – 3; 48 ÷ 6. Participants (N = 109 solved arithmetic problems from one of the four operations while their eye movements were recorded. We found three unique fixation patterns. During addition and multiplication, participants allocated half of their fixations to the operator and one-quarter to each operand, independent of problem size. The pattern was similar on small subtraction and division problems. However, on large subtraction problems, fixations were distributed approximately evenly across the three stimulus components. On large division problems, over half of the fixations occurred on the left operand, with the rest distributed between the operation sign and the right operand. We discuss the relations between these eye tracking patterns and other research on the differences in processing across arithmetic operations.

  10. Headspace analysis of foams and fixatives

    Energy Technology Data Exchange (ETDEWEB)

    Harper, Kyle [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Truong, Thanh-Tam [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Magwood, Leroy [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Peters, Brent [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Nicholson, James [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Washington, II, Aaron L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-07-27

    In the process of decontaminating and decommissioning (D&D) older nuclear facilities, special precautions must be taken with removable or airborne contamination. One possible strategy utilizes foams and fixatives to affix these loose contaminants. Many foams and fixatives are already commercially available, either generically or sold specifically for D&D. However, due to a lack of revelant testing in a radioactive environment, additional verification is needed to confirm that these products not only affix contamination to their surfaces, but also will function in a D&D environment. Several significant safety factors, including flammability and worker safety, can be analyzed through the process of headspace analysis, a technique that analyzes the off gas formed before or during the curing process of the foam/fixative, usually using gas chromatography-mass spectrometry (GC-MS). This process focuses on the volatile components of a chemical, which move freely between the solid/liquid form within the sample and the gaseous form in the area above the sample (the headspace). Between possibly hot conditions in a D&D situation and heat created in a foaming reaction, the volatility of many chemicals can change, and thus different gasses can be released at different times throughout the reaction. This project focused on analysis of volatile chemicals involved in the process of using foams and fixatives to identify any potential hazardous or flammable compounds.

  11. Numerical analysis oriented biaxial stress-strain relation and failure criterion of plain concrete

    International Nuclear Information System (INIS)

    Link, J.

    1975-01-01

    A biaxial stress-strain relation and failure criterion is proposed, which is applicable to structural analysis methods. The formulation of material behavior of plain concrete in biaxial stress-state was developed. A nonlinear elastic, anisotropic stress-strain relation was derived with two moduli of elasticity, E 1 , E 2 and Poisson's ratios, ν 1 , ν 2 , which depend on the prevailing biaxial stress state. The stress-strain relation is valid in the whole biaxial stress field, that means with a smooth transition between the domains of tension/tension, tension/compression and compression/compression. The stress-dependent moduli E 1 , E 2 and the Poisson's ratios ν 1 , ν 2 are approximated by polynomials, trigonometrical and exponential functions. A failure criterion was defined by approximating the test results of the biaxial ultimate concrete strength with a 7th degree polynomial, which is also valid in the whole biaxial stress domain. The definition of the state of failure is given as a function of stresses as well as strains. Initial parameters of the formulation of the biaxial material behavior are the uniaxial cylindrical strength of concrete and the initial values of Young's modulus and Poisson's ratio. A simple expansion of this formulation makes it applicable not only to normal but also to light-weight concrete. Comparison of numerically calculated stress-strain curves up to the ultimate biaxial stresses which indicate the failure criteria with those obtained from tests show a very good agreement. It is shown, that the biaxial stress-strain relation can be extended for use in cases of triaxial tension/tension/compression stress state. Numerical examples of analysis of concrete slabs show the importance of incorporation of a realistic material behavior for better safety estimations

  12. Restriction of Postoperative Joint Loading in a Murine Model of Anterior Cruciate Ligament Reconstruction: Botulinum Toxin Paralysis and External Fixation.

    Science.gov (United States)

    Lebaschi, Amir; Deng, Xiang-Hua; Coleman, Nathan W; Camp, Christopher L; Zong, Jianchun; Carbone, Andrew; Carballo, Camila B; Cong, Guang-Ting; Album, Zoe M; Rodeo, Scott A

    2017-09-01

    Control of knee motion in small animal models is necessary to study the effect of mechanical load on the healing process. This can be especially challenging in mice, which are being increasingly used for various orthopedic reconstruction models. We explored the feasibility of botulinum toxin (Botox; Allergan, Dublin, Ireland) paralysis and a newly designed external fixator to restrict motion of the knee in mice undergoing anterior cruciate ligament (ACL) reconstruction. Nineteen C57BL/6 mice were allocated to two groups: (1) Botox group ( n  = 9) and (2) external fixator group ( n  = 10). Mice in Botox group received two different doses of Botox: 0.25 unit ( n  = 3) and 0.5 unit ( n  = 6). Injection was performed 72 hours prior to ACL reconstruction into the quadriceps, hamstring, and calf muscles of the right hind leg. Mice in external fixator group received an external fixator following ACL reconstruction. Mice were monitored for survival, tolerance, and achievement of complete knee immobilization. All mice were meant for sacrifice on day 14 postoperatively. No perceptible change in gait was observed with 0.25 unit of Botox. All mice that received 0.5 unit of Botox had complete hind limb paralysis documented by footprint analysis 2 days after injection but failed to tolerate anesthesia and were euthanized 24 hours after operation due to their critical condition. In contrast, the external fixator was well tolerated and effectively immobilized the limb. There was a single occurrence of intraoperative technical error in the external fixator group that led to euthanasia. No mechanical failure or complication was observed. Botox paralysis was not a viable option for postoperative restriction of motion and joint loading in mice. However, external fixation was an effective method for complete knee immobilization and can be used in murine models requiring postoperative control of knee loading. This study introduces a robust research tool to allow control

  13. CONTRIBUTION TO THE STUDY OF DUNES FIXATION IN THE SEMI-ARIDE ENVIRONMENT: ALGERIA

    Directory of Open Access Journals (Sweden)

    Saida Akkouche

    2017-05-01

    Full Text Available In our study,of dune fixation , spontaneous vegetation was installed inside the grid. Over the years, plant diversity has improved with74 species in 2009 (22 families and 61 genera, demonstrating a significant reduction of troubles, caused especially by the erosive action of winds and other microclimate factors. Indeed, in non-fixed dunes (mechanical and biological fixation vegetation is particularly present in the lower slopes of the dunes shelter where humidity is relatively high and the soil fertile. But in fixed environments, vegetation climbs to the top of dunes, improving: I The Microclimate; creating a gentle atmosphere under the effect of shade and transpiration; II Floor; increasing its humidity and improving its fertility through the provision of litter. On all of the fixed dunes and under the feet of planted species a surface layer of soil , sometimes reduced in a few centimeters, is formed by fine particles of clays and acting as a shield which reduces evaporation and therefore allows a relatively large water retention preserved for a longer period of the year. This layer is called "Self-mulching" is a colloidal material which sticks the sand after a biological dune fixation.

  14. Results of an aging-related failure survey of light water safety systems and components

    International Nuclear Information System (INIS)

    Meale, B.M.; Satterwhite, D.G.; MacDonald, P.E.

    1988-01-01

    The collection and evaluation of operating experience data are necessary in determining the effects of aging on the safety of operating nuclear plants. This paper presents the final results of a two-year research effort evaluating aging impacts on components in light water reactor systems. This research was performed as a part of the Nuclear Plant Aging Research program, sponsored by the US Nuclear Regulatory Commission. Two unique types of data analyses were performed. In the first, an aging-survey study, aging-related failure data for fifteen light water reactor systems were obtained from the Nuclear Plant Reliability Data System (NPRDS). These included safety, support, and power conversion systems. A computerized sort of these records classified each record into one of five generic categories, based on the utility's choice of the failure's NPRDS cause category. Systems and components within the systems that were most affected by aging were identified. In the second analysis, information on aging-related reported causes of failures was evaluated for component failures reported to NPRDS for auxiliary feedwater, high pressure injection, service water, and Class 1E electrical power distribution systems. 3 refs., 13 figs., 4 tabs

  15. Comparing fixation used for calcaneal displacement osteotomies: a look at removal rates and cost.

    Science.gov (United States)

    Lucas, Douglas E; Simpson, G Alex; Philbin, Terrence M

    2015-02-01

    The calcaneal displacement osteotomy is a procedure frequently used by foot and ankle surgeons for hindfoot angular deformity. Traditional techniques use compression screw fixation that can result in prominent hardware. While the results of the procedure are generally good, a common concern is the development of plantar heel pain related to prominent hardware. The primary purpose of this study is to retrospectively compare clinical outcomes of 2 fixation methods for the osteotomy. Secondarily a cost analysis will compare implant costs to hardware removal costs. Records were reviewed for patients who had undergone a calcaneal displacement osteotomy fixated with either lag screw or a locked lateral compression plate (LLCP). Neuropathy, previous ipsilateral calcaneus surgery, heel pad trauma, or incomplete radiographic follow-up were exclusionary. Thirty-two patients (19.4%) required hardware removal from the screw fixation group compared to 1 (1.6%) of the LLCP group, which is significant (P cost was remarkably different with screw fixation costing on average $247.12, compared to the LLCP costing $1175.59. Although the LLCP cost was significantly higher, cost savings were identified when the cost of removal and removal rates were included. This study demonstrates that this device provides adequate stabilization for healing in equivalent time to screw fixation. The LLCP required decreased rates of hardware removal with fewer postoperative visits over a shorter period of time. Significant savings were demonstrated in the LLCP group despite the higher implant cost. Therapeutic, Level III, Retrospective Comparative Study. © 2014 The Author(s).

  16. Biometric recognition via fixation density maps

    Science.gov (United States)

    Rigas, Ioannis; Komogortsev, Oleg V.

    2014-05-01

    This work introduces and evaluates a novel eye movement-driven biometric approach that employs eye fixation density maps for person identification. The proposed feature offers a dynamic representation of the biometric identity, storing rich information regarding the behavioral and physical eye movement characteristics of the individuals. The innate ability of fixation density maps to capture the spatial layout of the eye movements in conjunction with their probabilistic nature makes them a particularly suitable option as an eye movement biometrical trait in cases when free-viewing stimuli is presented. In order to demonstrate the effectiveness of the proposed approach, the method is evaluated on three different datasets containing a wide gamut of stimuli types, such as static images, video and text segments. The obtained results indicate a minimum EER (Equal Error Rate) of 18.3 %, revealing the perspectives on the utilization of fixation density maps as an enhancing biometrical cue during identification scenarios in dynamic visual environments.

  17. Large fluctuations and fixation in evolutionary games

    International Nuclear Information System (INIS)

    Assaf, Michael; Mobilia, Mauro

    2010-01-01

    We study large fluctuations in evolutionary games belonging to the coordination and anti-coordination classes. The dynamics of these games, modeling cooperation dilemmas, is characterized by a coexistence fixed point separating two absorbing states. We are particularly interested in the problem of fixation that refers to the possibility that a few mutants take over the entire population. Here, the fixation phenomenon is induced by large fluctuations and is investigated by a semiclassical WKB (Wentzel–Kramers–Brillouin) theory generalized to treat stochastic systems possessing multiple absorbing states. Importantly, this method allows us to analyze the combined influence of selection and random fluctuations on the evolutionary dynamics beyond the weak selection limit often considered in previous works. We accurately compute, including pre-exponential factors, the probability distribution function in the long-lived coexistence state and the mean fixation time necessary for a few mutants to take over the entire population in anti-coordination games, and also the fixation probability in the coordination class. Our analytical results compare excellently with extensive numerical simulations. Furthermore, we demonstrate that our treatment is superior to the Fokker–Planck approximation when the selection intensity is finite

  18. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  19. Heart failure and 1231-M.I.B.G. scintigraphy: comeback; Scintigraphie cardiaque a la 1231-metaiodobenzylguanidine et cardiomyopathies: le retour

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, D.; Hugentobler, A.; Costo, S.; Bouvard, G. [Centre Hospitalier Universitaire Cote de Nacre, Service de Medecine Nucleaire, 14 - Caen (France); Manrique, A. [Centre de Lutte Contre le Cancer Henri-Becquerel, Service de Medecine Nucleaire, 76 - Rouen (France); Sabatier, R.; Grollier, G. [Centre Hospitalier Universitaire Cote de Nacre, Service de Cardiologie, 14 - Caen (France); Belin, A. [Hopital de Trouville, Service de Readaptation Cardiaque, 14 - Trouville (France)

    2007-09-15

    Congestive heart failure is a often associated with an impairment of sympathetic nervous system, i.e., global hyperactivity and regional impairment of adrenergic system. Cardiac {sup 123}I-meta-iodo-benzyl-guanidine (M.I.B.G.) scintigraphy is a radionuclide technique which can explore the presynaptic adrenergic function. Cardiac fixation of M.I.B.G. is decreased in congestive heart failure, reflecting a reduction of norepinephrine uptake by the myocardial presynaptic ending nerves. The impairment of presynaptic function is early and actually involved in the pathogenesis of cardiac failure. Cardiac M.I.B.G. scintigraphy is a useful tool to explore the myocardial adrenergic stores in patients with congestive heart failure. (authors)

  20. Failure modes of safety-related components at fires on nuclear power plants

    International Nuclear Information System (INIS)

    Aaslund, A.

    2000-03-01

    Probabilistic assessment methods can be used to identify specific plant vulnerabilities. Application of such methods can also facilitate selection among system design alternatives available for safety enhancements. The quality of assessment results is however strongly dependent on realistic and accurate input data for modelling of system component behaviour and failure modes during conditions to be assessed. Use of conservative input data may not lead to results providing guidance on safety upgrades. Adequate input data for probabilistic assessments seems to be lacking for at least failure modes of some electrical components when exposed to a fire. This report presents an attempt to improve the situation with respect to such input data. In order to take advantage of information in existing documentation of fire incident occurrences some of the lessons learned from the fire at Browns Ferry Nuclear Power Plant on March 22, 1975 are discussed in this report. Also a summary of results from different fire tests of electrical cables presented in a fire risk analysis report is a part of the references. The failure modes used to describe fire-induced damage are 'open circuit' and 'hot short' which seems to be commonly accepted terms within the branch. Definitions of the terms are included in the report. Effects of the failure modes when occurring in some of the channels of the reactor protection system are discussed with respect to the existing design of the reactor protection system at Ringhals 2 nuclear power unit. Experiences from the Browns Ferry fire and results from fire tests of electrical cables indicate that the dominating failure mode for electrical cables is 'open circuit'. An 'open circuit' failure leads to circuit disjunction and loss of continuity. The circuit can no longer transmit its signal or power. When affecting channels of the reactor protection system an 'open circuit' failure can cause extensive inadvertent actions of safety related equipment

  1. The Impact of Task Demands on Fixation-Related Brain Potentials during Guided Search.

    Directory of Open Access Journals (Sweden)

    Anthony J Ries

    Full Text Available Recording synchronous data from EEG and eye-tracking provides a unique methodological approach for measuring the sensory and cognitive processes of overt visual search. Using this approach we obtained fixation related potentials (FRPs during a guided visual search task specifically focusing on the lambda and P3 components. An outstanding question is whether the lambda and P3 FRP components are influenced by concurrent task demands. We addressed this question by obtaining simultaneous eye-movement and electroencephalographic (EEG measures during a guided visual search task while parametrically modulating working memory load using an auditory N-back task. Participants performed the guided search task alone, while ignoring binaurally presented digits, or while using the auditory information in a 0, 1, or 2-back task. The results showed increased reaction time and decreased accuracy in both the visual search and N-back tasks as a function of auditory load. Moreover, high auditory task demands increased the P3 but not the lambda latency while the amplitude of both lambda and P3 was reduced during high auditory task demands. The results show that both early and late stages of visual processing indexed by FRPs are significantly affected by concurrent task demands imposed by auditory working memory.

  2. Modeling the impact of iron and phosphorus limitations on nitrogen fixation in the Atlantic Ocean

    Directory of Open Access Journals (Sweden)

    R. R. Hood

    2007-07-01

    Full Text Available The overarching goal of this study is to simulate subsurface N* (sensu, Gruber and Sarmiento, 1997; GS97 anomaly patterns in the North Atlantic Ocean and determine the basin wide rates of N2-fixation that are required to do so. We present results from a new Atlantic implementation of a coupled physical-biogeochemical model that includes an explicit, dynamic representation of N2-fixation with light, nitrogen, phosphorus and iron limitations, and variable stoichiometric ratios. The model is able to reproduce nitrogen, phosphorus and iron concentration variability to first order. The latter is achieved by incorporating iron deposition directly into the model's detrital iron compartment which allows the model to reproduce sharp near surface gradients in dissolved iron concentration off the west coast of Africa and deep dissolved iron concentrations that have been observed in recent observational studies. The model can reproduce the large scale N* anomaly patterns but requires relatively high rates of surface nitrogen fixation to do so (1.8×1012 moles N yr−1 from 10° N–30° N, 3.4×1012 moles N yr−1 from 25° S–65° N. In the model the surface nitrogen fixation rate patterns are not co-located with subsurface gradients in N*. Rather, the fixed nitrogen is advected away from its source prior to generating a subsurface N* anomaly. Changes in the phosphorus remineralization rate (relative to nitrogen linearly determine the surface nitrogen fixation rate because they change the degree of phosphorus limitation, which is the dominant limitation in the Atlantic in the model. Phosphorus remineralization rate must be increased by about a factor of 2 (relative to nitrogen in order to generate subsurface N* anomalies that are comparable to the observations. We conclude that N2-fixation rate estimates for the Atlantic (and globally may need to be revised upward, which

  3. The Role of Personality and Team-Based Product Dissection on Fixation Effects

    Science.gov (United States)

    Toh, Christine; Miller, Scarlett; Kremer, Gül E. Okudan

    2013-01-01

    Design fixation has been found to be complex in its definition and expression, but it plays an important role in design idea generation. Identifying the factors that influence fixation is crucial in understanding how to enhance the design process and reduce the negative effects of fixation. One way to potentially mitigate fixation is through…

  4. The influence of phosphorus deficiency on growth and nitrogen fixation of white clover plants

    OpenAIRE

    Høgh-Jensen, Dr Henning; Schjoerring, Dr Jan K.; Soussana, Dr Jean-Francois

    2002-01-01

    The effects of P deficiency on growth, N2‐fixation and photosynthesis in white clover (Trifolium repens L.) plants were investigated using three contrasting relative addition rates of P, or following abrupt withdrawal of the P supply. Responses to a constant below‐optimum P supply rate consisted of a decline in N2‐fixation per unit root weight and a small reduction in the efficiency with which electrons were allocated to the reduction of N2 in nodules. Abrupt removal of P arrested nodule grow...

  5. Environmental and biogeochemical controls on N2 fixation in ombrotrophic peatlands

    Science.gov (United States)

    Zivkovic, T.; Moore, T. R.

    2017-12-01

    Northern peatlands have low atmospheric nitrogen (N) inputs and acquire N mostly via biological, microbially-driven N2-fixation. Little is known about rates and controls on N2-fixation in ombrotrophic bogs. We conducted two studies to test environmental and biogeochemical controls on N2-fixation. First, we used acetylene reduction assay (ARA) calibrated with 15N2 tracer to measure N2-fixation rates in three species of Sphagnum mosses along a hydrological gradient (beaver pond, hollow and hummock in bog margin and in bog) at Mer Bleue bog from June-October 2013 and May - November 2014. We tested the following controls: moisture availability, temperature, and PAR. The largest ARA rates throughout both seasons occurred in the pond in floating Sphagnum cuspidatum mats (50.3 ± 12.9 μmol m-2 d-1 Mean ± SE), which were up to 2.5 times larger than the rates found in the driest hummock site. There was a significant seasonal peak in both years in July and early August that coincided with the peak of the air temperature. In fact, 45% of the variance of N2 fixation rates over the two field seasons was explained by rain events, water table fluctuations and the surface peat temperature (multiple regression analysis, n = 539). Our results highlight the potential impact of climate change, namely negative effects due to potential droughts and positive effect of warming, on N2 fixation patterns in ombrotrophic peatlands. Secondly, we tested stoichiometric controls (Sphagnum tissue N and phosphorous (P) ratio) of N2-fixation. In a controlled environment, we selected eight study sites along a latitudinal gradient from temperate, boreal to subarctic zone in eastern Canada. We found that decreasing N:P ratio corresponded to increasing N2-fixation. N:P explained 65% of the variance in N2-fixation in hollows but only 20% in hummocks. Changes in neither N or P concentration alone explained the increase in N2-fixation better than N:P ratio. We interpret that the difference between

  6. Elevated CO2 concentration around alfalfa nodules increases N2 fixation

    OpenAIRE

    Fischinger, Stephanie A.; Hristozkova, Marieta; Mainassara, Zaman-Allah; Schulze, Joachim

    2009-01-01

    Nodule CO2 fixation via PEPC provides malate for bacteroids and oxaloacetate for N assimilation. The process is therefore of central importance for efficient nitrogen fixation. Nodule CO2 fixation is known to depend on external CO2 concentration. The hypothesis of the present paper was that nitrogen fixation in alfalfa plants is enhanced when the nodules are exposed to elevated CO2 concentrations. Therefore nodulated plants of alfalfa were grown in a hydroponic system that allowed separate ae...

  7. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Cosmetic arm lengthening with monorail fixator.

    Science.gov (United States)

    Agrawal, Hemendra Kumar; Singh, Balvinder; Garg, Mohit; Khatkar, Vipin; Batra, Sumit; Sharma, Vinod Kumar

    2015-01-01

    Upper limb length discrepancy is a rare occurrence. Humerus shortening may need specialized treatment to restore the functional and cosmetic status of upper limb. We report a case of humerus lengthening of 9 cm with a monorail external fixator and the result was observed during a 2-year follow-up. Humerus lengthening needs specialized focus as it is not only a cosmetic issue but also a functional demand. The monorail unilateral fixator is more functional and cosmetically acceptable, and thus becomes an effective treatment option.

  9. Outcomes of percutaneous pedicle screw fixation for spinal trauma and tumours.

    Science.gov (United States)

    Mobbs, Ralph J; Park, Ashley; Maharaj, Monish; Phan, Kevin

    2016-01-01

    We investigated the clinical and radiological results of percutaneous pedicle screw fixation in the management of spinal trauma and metastatic tumours. A retrospective analysis was performed on a series of 14 patients who were operated on from March 2009 to November 2011 by a single surgeon (RJM). Following a radiological review (CT scan/MRI), six patients underwent short segment fixation, while the remaining underwent long segment fixation. All patients had routine follow-ups at 4, 6, 12months, and annually thereafter. Clinical examinations were conducted preoperatively and postoperatively, and the length of operation, blood loss, and postoperative pain relief were recorded. There was a single patient with an incision site complication. The mean blood loss was 269mL. All of the parameters demonstrated no significant differences between the trauma and the tumour groups (p=0.10). The neurological power scores improved for all patients, with the largest increase being from a score of 2 to 4. At follow-up, the majority of patients had returned to their previous activities and had reduced pain scores. One patient suffered high pain levels from other medical conditions that were not related to the operation. Minimally invasive pedicle screw fixation is a suitable option for patients with spinal tumours and fractures, with acceptable safety and efficacy in this small retrospective patient series. We have seen favourable results in our patients, who have experienced an increased quality of life following their surgery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Modified fixation with pinning and external fixation components for feline femur multiple-lined fracture: A case report

    International Nuclear Information System (INIS)

    Okamoto, Y.; Minami, S.; Matuhashi, A.

    1992-01-01

    A 3-year-old female Japanese domestic cat, weighing 3kg, was referred to us because of right hind leg lameness occuring for 3 days' duration. Radiography of the affected leg revealed severe femoral diaphysial comminuted fracture. The affected leg was treated using wire with an intramedullary Stainman pin being placed completely through the femur. After suturing the wound, both ends of the intramedullary pin exposed both proximally and distally were fixed with external fixation components (two double clamps, two single clamps, two short rods and one long rod) to prevent the pin from rotation. There was a slight gait problem due to the external apparatus and no post-operative infection. The function of the right hind leg gradually recovered. The intramedullary pin and external fixative apparatus were removed on the 52nd day after surgery. This modified fixation appears to offer versatility in the treatment of various fractures in smaller dogs and cats

  11. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures

    OpenAIRE

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2014-01-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3–12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and...

  12. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  13. Evaluation of Fibular Fracture Type vs Location of Tibial Fixation of Pilon Fractures.

    Science.gov (United States)

    Busel, Gennadiy A; Watson, J Tracy; Israel, Heidi

    2017-06-01

    Comminuted fibular fractures can occur with pilon fractures as a result of valgus stress. Transverse fibular fractures can occur with varus deformation. No definitive guide for determining the proper location of tibial fixation exists. The purpose of this study was to identify optimal plate location for fixation of pilon fractures based on the orientation of the fibular fracture. One hundred two patients with 103 pilon fractures were identified who were definitively treated at our institution from 2004 to 2013. Pilon fractures were classified using the AO/OTA classification and included 43-A through 43-C fractures. Inclusion criteria were age of at least 18 years, associated fibular fracture, and definitive tibial plating. Patients were grouped based on the fibular component fracture type (comminuted vs transverse), and the location of plate fixation (medial vs lateral) was noted. Radiographic outcomes were assessed for mechanical failures. Forty fractures were a result of varus force as evidenced by transverse fracture of the fibula and 63 were due to valgus force with a comminuted fibula. For the transverse fibula group, 14.3% mechanical complications were noted for medially placed plate vs 80% for lateral plating ( P = .006). For the comminuted fibular group, 36.4% of medially placed plates demonstrated mechanical complications vs 16.7% for laterally based plates ( P = .156). Time to weight bearing as tolerated was also noted to be significant between groups plated medially and laterally for the comminuted group ( P = .013). Correctly assessing the fibular component for pilon fractures provides valuable information regarding deforming forces. To limit mechanical complications, tibial plates should be applied in such a way as to resist the original deforming forces. Level of Evidence Level III, comparative study.

  14. Bacterial N2-fixation in mangrove ecosystems: insights from a diazotroph-mangrove interaction.

    Science.gov (United States)

    Alfaro-Espinoza, Gabriela; Ullrich, Matthias S

    2015-01-01

    Mangrove forests are highly productive ecosystems but represent low nutrient environments. Nitrogen availability is one of the main factors limiting mangrove growth. Diazotrophs have been identified as key organisms that provide nitrogen to these environments. N2-fixation by such organisms was found to be higher in the mangrove roots than in surrounding rhizosphere. Moreover, previous studies showed that mangroves grew better in the presence of N2-fixers indicating a potentially mutualistic relationship. However, the molecular signals and mechanisms that govern these interactions are still poorly understood. Here we present novel insights in the interaction of a diazotroph with a mangrove species to improve our understanding of the molecular and ecophysiological relationship between these two organisms under controlled conditions. Our results showed that Marinobacterium mangrovicola is a versatile organism capable of competing with other organisms to survive for long periods in mangrove soils. N2-fixation by this bacterium was up-regulated in the presence of mangrove roots, indicating a possible beneficial interaction. The increase in N2-fixation was limited to cells of the exponential growth phase suggesting that N2-fixation differs over the bacterial growth cycle. Bacterial transformants harboring a transcriptional nifH::gusA fusion showed that M. mangrovicola successfully colonized mangrove roots and simultaneously conducted N2-fixation. The colonization process was stimulated by the lack of an external carbon source suggesting a possible mutualistic relationship. M. mangrovicola represents an interesting genetically accessible diazotroph, which colonize mangrove roots and exhibit higher N2-fixation in the presence of mangrove roots. Consequently, we propose this microorganism as a tool to study molecular interactions between N2-fixers and mangrove plants and to better understand how changes in the environment could impact these important and relatively unknown

  15. Buckminsterfullerenes: a non-metal system for nitrogen fixation.

    Science.gov (United States)

    Nishibayashi, Yoshiaki; Saito, Makoto; Uemura, Sakae; Takekuma, Shin-Ichi; Takekuma, Hideko; Yoshida, Zen-Ichi

    2004-03-18

    In all nitrogen-fixation processes known so far--including the industrial Haber-Bosch process, biological fixation by nitrogenase enzymes and previously described homogeneous synthetic systems--the direct transformation of the stable, inert dinitrogen molecule (N2) into ammonia (NH3) relies on the powerful redox properties of metals. Here we show that nitrogen fixation can also be achieved by using a non-metallic buckminsterfullerene (C60) molecule, in the form of a water-soluble C60:gamma-cyclodextrin (1:2) complex, and light under nitrogen at atmospheric pressure. This metal-free system efficiently fixes nitrogen under mild conditions by making use of the redox properties of the fullerene derivative.

  16. Exchange nailing for nonunion of diaphyseal fractures of the tibia: our results and an analysis of the risk factors for failure.

    Science.gov (United States)

    Tsang, S T J; Mills, L A; Frantzias, J; Baren, J P; Keating, J F; Simpson, A H R W

    2016-04-01

    The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures. A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months). The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union. Multiple causes for the primary nonunion were found for 28 (27%) tibiae, with infection present in 32 (31%). Six patients were lost to follow-up. Further surgical procedures were required in 35 (36%) nonunions. Other fixation modalities were required in five fractures. A single nail exchange procedure achieved union in 60/96 (63%) of all nonunions. Only 11 out of 31 infected nonunions (35.4%) healed after one exchange nail procedure. Up to five repeated exchange nailings, with or without bone grafting, ultimately achieved union in 89 (93%) fractures. The median time to union after exchange nailing was 8.7 months (IQR 5.7 to 14.0 months). Univariate analysis confirmed that an oligotrophic/atrophic pattern of nonunion (p = 0.002), a bone gap of 5 mm or more (p = 0.04) and infection (p exchange nailing Multiple regression analysis found that infection was the strongest predictor of failure (p Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. However, in the presence of severe infection with a highly resistant organism, or extensive sclerosis of the bone, other fixation modalities, such as Ilizarov treatment, should be considered. Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. ©2016 The British Editorial

  17. Feasibility of pig and human-derived aortic valve interstitial cells seeding on fixative-free decellularized animal pericardium.

    Science.gov (United States)

    Santoro, Rosaria; Consolo, Filippo; Spiccia, Marco; Piola, Marco; Kassem, Samer; Prandi, Francesca; Vinci, Maria Cristina; Forti, Elisa; Polvani, Gianluca; Fiore, Gianfranco Beniamino; Soncini, Monica; Pesce, Maurizio

    2016-02-01

    Glutaraldehyde-fixed pericardium of animal origin is the elective material for the fabrication of bio-prosthetic valves for surgical replacement of insufficient/stenotic cardiac valves. However, the pericardial tissue employed to this aim undergoes severe calcification due to chronic inflammation resulting from a non-complete immunological compatibility of the animal-derived pericardial tissue resulting from failure to remove animal-derived xeno-antigens. In the mid/long-term, this leads to structural deterioration, mechanical failure, and prosthesis leaflets rupture, with consequent need for re-intervention. In the search for novel procedures to maximize biological compatibility of the pericardial tissue into immunocompetent background, we have recently devised a procedure to decellularize the human pericardium as an alternative to fixation with aldehydes. In the present contribution, we used this procedure to derive sheets of decellularized pig pericardium. The decellularized tissue was first tested for the presence of 1,3 α-galactose (αGal), one of the main xenoantigens involved in prosthetic valve rejection, as well as for mechanical tensile behavior and distensibility, and finally seeded with pig- and human-derived aortic valve interstitial cells. We demonstrate that the decellularization procedure removed the αGAL antigen, maintained the mechanical characteristics of the native pig pericardium, and ensured an efficient surface colonization of the tissue by animal- and human-derived aortic valve interstitial cells. This establishes, for the first time, the feasibility of fixative-free pericardial tissue seeding with valve competent cells for derivation of tissue engineered heart valve leaflets. © 2015 Wiley Periodicals, Inc.

  18. A comparison of two fixation methods for femoral trochanteric fractures: a new generation intramedullary system vs sliding hip screw.

    Science.gov (United States)

    Carulli, Christian; Piacentini, Federico; Paoli, Tommaso; Civinini, Roberto; Innocenti, Massimo

    2017-01-01

    Trochanteric fractures are frequent and generally associated with bone fragility. There is still debate on the best fixation device to treat stable or rather stable trochanteric fractures: we report our clinical and radiological results of fixation with Proximal Femoral Nail "antirotation" (PFNa) in a population of patients compared to a control group treated by Sliding Hip Screw (SHS). A prospective study was conducted in 71 consecutive patients treated by PFNa (group A), and 69 by a SHS (group B), with a mean age of 81.6 and 83.4 years respectively. Short Form 12 was administered to check postoperative results, and the following parameters were evaluated: range of motion, evaluation of pain, gait ability, X-rays, and Tip Apex Distance Index. A minimum follow-up was conducted in 128 patients: 66 subjects belonging to the PFNa group and 62 to the DHS group. All patients in the group A were able to reach partial or full weight-bearing on the operated leg before leaving the hospital. Forty-four patients (63.8%) of the group B were able to walk with partial weight-bearing before discharge. We recorded 17 complications with a final overall percentage of 17.2% on the overall study population with one single case of failure in both the two groups. A statistical significance (ptrochanteric fractures as well as DHS. The light superiority of PFNa may be principally related to its mechanical advantages.

  19. Narcissistic disorder and the failure of symbolisation: a Relational Affective Hypothesis.

    Science.gov (United States)

    Mizen, C S

    2014-09-01

    The psychoanalytic concept of narcissistic disorder is broader than that of Narcissistic Personality Disorder (DSM-5 [1]), underlying a range of Personality Disorders (PD) and their co-morbidities. Existing Mentalisation, Psychoanalytic and Cognitive models, fail to account fully for the emerging evidence of biological, developmental, relational and defensive contributions to narcissistic disorder, nor do they account for the common and variant features of co-morbidities namely Anorexia Nervosa, Somatisation, Substance Misuse and Autistic Spectrum Disorder. Alexithymia and concrete modes of relating are common findings in narcissistic disorder and these co-morbid conditions. Current models do not provide a comprehensive account, on the basis of neuro-scientific and developmental evidence, of how affective feelings come to be represented in words and the association between narcissistic disorders and failures of symbolisation. In this paper I propose an empirically based Relational Affective Hypothesis that narcissistic disorder and its comorbidities represent failures at specific points on a representational function pathway through which subcortical affect and visceral feeling in a relational context become the basis for abstraction and language. The elucidation of this pathway allows investigation of the contribution of biological, social and psychogenic factors in narcissistic disorders. It also brings a new understanding of the neurological underpinning of psychodynamic defences in narcissistic disorders. Research and novel treatment implications are briefly considered. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Benthic N2 fixation in coral reefs and the potential effects of human-induced environmental change

    Science.gov (United States)

    Cardini, Ulisse; Bednarz, Vanessa N; Foster, Rachel A; Wild, Christian

    2014-01-01

    Tropical coral reefs are among the most productive and diverse ecosystems, despite being surrounded by ocean waters where nutrients are in short supply. Benthic dinitrogen (N2) fixation is a significant internal source of “new” nitrogen (N) in reef ecosystems, but related information appears to be sparse. Here, we review the current state (and gaps) of knowledge on N2 fixation associated with coral reef organisms and their ecosystems. By summarizing the existing literature, we show that benthic N2 fixation is an omnipresent process in tropical reef environments. Highest N2 fixation rates are detected in reef-associated cyanobacterial mats and sea grass meadows, clearly showing the significance of these functional groups, if present, to the input of new N in reef ecosystems. Nonetheless, key benthic organisms such as hard corals also importantly contribute to benthic N2 fixation in the reef. Given the usually high coral coverage of healthy reef systems, these results indicate that benthic symbiotic associations may be more important than previously thought. In fact, mutualisms between carbon (C) and N2 fixers have likely evolved that may enable reef communities to mitigate N limitation. We then explore the potential effects of the increasing human interferences on the process of benthic reef N2 fixation via changes in diazotrophic populations, enzymatic activities, or availability of benthic substrates favorable to these microorganisms. Current knowledge indicates positive effects of ocean acidification, warming, and deoxygenation and negative effects of increased ultraviolet radiation on the amount of N fixed in coral reefs. Eutrophication may either boost or suppress N2 fixation, depending on the nutrient becoming limiting. As N2 fixation appears to play a fundamental role in nutrient-limited reef ecosystems, these assumptions need to be expanded and confirmed by future research efforts addressing the knowledge gaps identified in this review. PMID:24967086

  1. Nitrogen fixation by free-living organisms in rice soils. Studies with 15N

    International Nuclear Information System (INIS)

    Rao, V.R.; Charyulu, P.B.B.N.; Nayak, D.N.; Ramakrishna, C.

    1979-01-01

    Heterotrophic nitrogen fixation as influenced by water regime, organic matter, combined nitrogen and pesticides was investigated in several Indian rice soils by means of the 15 N 2 tracer technique. Soil submergence accelerated nitrogen fixation. Addition of cellulose to both non-flooded and flooded soils enhanced nitrogen fixation. Under submerged conditions, addition of sucrose, glucose and malate in that order stimulated nitrogen fixation in alluvial soil, while only sucrose enhanced nitrogen fixation in laterite soil. Nitrogen fixation in flooded alluvial and laterite soils decreased with increasing concentration of combined nitrogen. Nitrogen fixation was appreciable in acid sulphate and saline soils under both flooded and non-flooded conditions, despite high salinity and acidity. Application of certain pesticides at rates equivalent to recommended field level greatly influenced nitrogen fixation in flooded rice soils. Additions of benomyl (carbamate fungicide) and carbofuran (methyl carbamate insecticide) to alluvial and laterite soils resulted in significant stimulation of nitrogen fixation. Gamma-BHC stimulated nitrogen fixation only in alluvial soil, with considerable inhibition in a laterite soil. Nitrogen fixation by Azospirillum lipoferum was investigated by 15 N 2 . Large variations in 15 N 2 incorporation by A. lipoferum isolated from the roots of several rice cultivars was observed. Specific lines of rice harbouring A. lipoferum with high nitrogenase activity might be selected. Nitrogen fixed by heterotrophic organisms in a complex system such as soil could not be evaluated precisely. Indigenous nitrogen fixation in a flooded soil would be in the range of 5-10 kg N/ha, increasable 3 to 4-fold by appropriate fertilizers and cultural practices

  2. Two-stage open reduction and internal fixation versus limited internal fixation combined with external fixation: a meta-analysis of postoperative complications in patients with severe Pilon fractures.

    Science.gov (United States)

    Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He

    2018-01-01

    Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.

  3. Free flap reconstructions of tibial fractures complicated after internal fixation.

    Science.gov (United States)

    Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S

    1995-04-01

    The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.

  4. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Directory of Open Access Journals (Sweden)

    Michael Bemelman

    2016-02-01

    Full Text Available More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

  5. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Science.gov (United States)

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  6. Fractures of the proximal fifth metatarsal: percutaneous bicortical fixation.

    Science.gov (United States)

    Mahajan, Vivek; Chung, Hyun Wook; Suh, Jin Soo

    2011-06-01

    Displaced intraarticular zone I and displaced zone II fractures of the proximal fifth metatarsal bone are frequently complicated by delayed nonunion due to a vascular watershed. Many complications have been reported with the commonly used intramedullary screw fixation for these fractures. The optimal surgical procedure for these fractures has not been determined. All these observations led us to evaluate the effectiveness of percutaneous bicortical screw fixation for treating these fractures. Twenty-three fractures were operatively treated by bicortical screw fixation. All the fractures were evaluated both clinically and radiologically for the healing. All the patients were followed at 2 or 3 week intervals till fracture union. The patients were followed for an average of 22.5 months. Twenty-three fractures healed uneventfully following bicortical fixation, with a mean healing time of 6.3 weeks (range, 4 to 10 weeks). The average American Orthopaedic Foot & Ankle Society (AOFAS) score was 94 (range, 90 to 99). All the patients reported no pain at rest or during athletic activity. We removed the implant in all cases at a mean of 23.2 weeks (range, 18 to 32 weeks). There was no refracture in any of our cases. The current study shows the effectiveness of bicortical screw fixation for displaced intraarticular zone I fractures and displaced zone II fractures. We recommend it as one of the useful techniques for fixation of displaced zone I and II fractures.

  7. Characterization for Soil Fixation by Polyelectrolyte Complex

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Suk; Kwon, Sang Woon; Yang, Heeman; Lee, Kune Woo; Seo, Bumkyoung; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    According to report, the radioactivity bulk (approx. 95%) is localized within topsoil. Therefore soil surface on topsoil should be fixed to prevent the spreading of the contaminated soils with Cs-137 by wind and water erosion. Many methods have been developing for soil fixation to remove radioactive contaminants in soil and prevent to diffuse radioactive materials. Various materials have been also used as fixatives such as clays, molecular sieves, polymer, and petroleum based products. One of the methods is a soil fixation or solidification using polyelectrolyte. Polyelectrolytes have many ionic groups and make into the polyelectrolyte complex (PEC) due to electrostatic interaction of polyanion and polycation in an aqueous solution. It can be avoids using the chemical cross-linking agents, and reducing the possible toxicity and other undesirable effects of the reagents. PEC can fix soil particles by flocculation and formation of crust between soil. The method can also prevent a spread of radioactive material by floating on a soil surface. Recently, PEC used for the solidification of soil near the Fukushima nuclear power plant in Japan. The decontamination efficiency of the surface soils reached 90%, and dust release was effectively suppressed during the removal of surface soils. In this study, it was investigated the fixation of the soil by PEC to avoid the spread of the contamination in addition to the separation of soil and PEC. The physicochemical properties of polyelectrolyte complex solution and the stability of fixed soil by PEC were investigated. The mode of the addition is important to prepare the polyelectrolytes complex without PAA agglomerate. The concentration of salt in the polyelectrolyte complex solution is a very important parameter for the soil fixation.

  8. Characterization for Soil Fixation by Polyelectrolyte Complex

    International Nuclear Information System (INIS)

    Choi, Yong Suk; Kwon, Sang Woon; Yang, Heeman; Lee, Kune Woo; Seo, Bumkyoung; Moon, Jei Kwon

    2014-01-01

    According to report, the radioactivity bulk (approx. 95%) is localized within topsoil. Therefore soil surface on topsoil should be fixed to prevent the spreading of the contaminated soils with Cs-137 by wind and water erosion. Many methods have been developing for soil fixation to remove radioactive contaminants in soil and prevent to diffuse radioactive materials. Various materials have been also used as fixatives such as clays, molecular sieves, polymer, and petroleum based products. One of the methods is a soil fixation or solidification using polyelectrolyte. Polyelectrolytes have many ionic groups and make into the polyelectrolyte complex (PEC) due to electrostatic interaction of polyanion and polycation in an aqueous solution. It can be avoids using the chemical cross-linking agents, and reducing the possible toxicity and other undesirable effects of the reagents. PEC can fix soil particles by flocculation and formation of crust between soil. The method can also prevent a spread of radioactive material by floating on a soil surface. Recently, PEC used for the solidification of soil near the Fukushima nuclear power plant in Japan. The decontamination efficiency of the surface soils reached 90%, and dust release was effectively suppressed during the removal of surface soils. In this study, it was investigated the fixation of the soil by PEC to avoid the spread of the contamination in addition to the separation of soil and PEC. The physicochemical properties of polyelectrolyte complex solution and the stability of fixed soil by PEC were investigated. The mode of the addition is important to prepare the polyelectrolytes complex without PAA agglomerate. The concentration of salt in the polyelectrolyte complex solution is a very important parameter for the soil fixation

  9. External fixation for closed pediatric femoral shaft fractures: where are we now?

    Science.gov (United States)

    Kong, Heather; Sabharwal, Sanjeev

    2014-12-01

    Recent advances in external fixation technique and pin design have sought to minimize complications such as pin site infection and premature removal of the external fixator. Although newer forms of internal fixation have gained popularity, external fixation may still have a role in managing pediatric femoral shaft fractures. We sought to assess the time to healing, limb alignment, and complications observed in a cohort of pediatric patients with closed femoral shaft fractures who were treated with external fixation. Over a 15-year period, one surgeon treated 289 pediatric patients with femur fractures, 31 (11%) of whom received an external fixator. The general indications for use of an external fixator during the period in question included length-unstable fractures, metadiaphyseal location, refracture, and pathologic fracture. Six patients (19%) had inadequate followup data and four patients (13%) were treated with a combination of flexible intramedullary nails and external fixation, leaving 21 patients for analysis. Mean age at injury was 10 years (range, 6-15 years) and followup averaged 22 months (range, 5-45 months) after removal of the fixator. Radiographs were examined for alignment and limb length discrepancy. Complications were recorded from a chart review. Mean time in the fixator was 17 weeks (range, 9-24 weeks). One patient sustained a refracture and one patient with an isolated femur fracture had a leg length discrepancy > 2 cm. There were no pin site infections requiring intravenous antibiotics or additional surgery. One patient with Blount disease and previous tibial osteotomy developed transient peroneal nerve palsy. Despite improvements in pin design and predictable fracture healing, complications such as refracture and leg length discrepancy after external fixation of pediatric femoral shaft fractures can occur. However, external fixation remains a viable alternative for certain fractures such as length-unstable fractures, metadiaphyseal

  10. Bioresorbable pins and interference screws for fixation of hamstring tendon grafts in anterior cruciate ligament reconstruction surgery: a randomized controlled trial.

    Science.gov (United States)

    Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael

    2009-09-01

    Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.

  11. Symbiotic N fixation of several soybean varieties and mutants

    International Nuclear Information System (INIS)

    Soertini, G.; Hendratno

    1988-01-01

    Symbiotic N fixation of several soybean varieties and mutants. Research activities comprising of three experiments were carried out to screen several soybean varieties and mutants for symbiotic N fixation potential. The first two experiments involved screening of seven rhizobium strains/isolate for effective N fixation. Depending on the medium used, plant response to strains was different. In sterile medium, rhizobium strain USDA 136, 142 and TAL 102 showed a high nitrogen fixation potential. In soil only rhizobium strain USDA 110 had better performance and proved to be competitive to the native strains. Nitrogen-15 dilution method was used to screen nitrogen fixing ability of several soybean varieties and mutants. Guntur variety showed a better response to high dose of N fertilizer without disturbance in its fixing ability. This variety then was considered good to be introduced in the cropping system. (author). 8 refs

  12. Loads applied to fixations for chain stretching

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, K; Brychta, P

    1985-06-01

    The chains of scraper chain conveyors must be pre-stretched during standstill in order to compensate the elongations occurring during operation. They require frequent retensiening in order to meet the varying operational requirements. During tensioning, the chains are fixed in a point in the top run by means of fixation elements. The authors present a method for calculating the retaining force needed in the fixations. There are three different initial conditions of the chain before trensioning: Tensionsfree chain, pretensioned chain (stressed chain), slack chain. In all three cases, it is important to find out whether or nor the tensioning drive reaches full speed. The method of calculation is illustrated by the example of a scraper chain conveyor; it enables the establishment of rules for tensioning without damaging the chain and is a good basis for the dimensioning of new types of fixation elements.

  13. Nitrogen fixation dynamics of two diazotrophic communities in Mono Lake, California

    Science.gov (United States)

    Oremland, R.S.

    1990-01-01

    Two types of diazotrophic microbial communities were found in the littoral zone of alkaline hypersaline Mono Lake, California. One consisted of anaerobic bacteria inhabiting the flocculent surface layers of sediments. Nitrogen fixation (acetylene reduction) by flocculent surface layers occurred under anaerobic conditions, was not stimulated by light or by additions of organic substrates, and was inhibited by O2, nitrate, and ammonia. The second community consisted of a ball-shaped association of a filamentous chlorophyte (Ctenocladus circinnatus) with diazotrophic, nonheterocystous cyanobacteria, as well as anaerobic bacteria (Ctenocladus balls). Nitrogen fixation by Ctenocladus balls was usually, but not always, stimulated by light. Rates of anaerobic dark fixation equaled those in the light under air. Fixation in the light was stimulated by 3-(3,4-dichlorophenyl)-1,1-dimethylurea and by propanil [N-(3,4-dichlorophenyl)propanamide]. 3-(3,4-Dichlorophenyl)-1,1-dimethyl urea-elicited nitrogenase activity was inhibited by ammonia (96%) and nitrate (65%). Fixation was greatest when Ctenocladus balls were incubated anaerobically in the light with sulfide. Dark anaerobic fixation was not stimulated by organic substrates in short-term (4-h) incubations, but was in long-term (67-h) ones. Areal estimates of benthic N2 fixation were measured seasonally, using chambers. Highest rates (~29.3 ??mol of C2H4 m-2 h-1) occurred under normal diel regimens of light and dark. These estimates indicate that benthic N2 fixation has the potential to be a significant nitrogen source in Mono Lake.

  14. A Novel Handmade External Fixator for Phalangeal and Metacarpal Fractures

    Directory of Open Access Journals (Sweden)

    Davod Jafari

    2016-12-01

    Full Text Available Background The value of external fixation in complex hand injuries is well established. Expenses and technical difficulties of commercial mini external fixator sets have led to the innovation of handmade external fixators. These fixators are used as versatile facilities to treat certain hand fractures. Usually, these structures are made by k-wires crossed filled with cement plastic tube. However, these fixators have multiple deficiencies that should be addressed. Objectives In this study, we described in detail the surgical technique of a handmade concrete like mini external fixator and report its clinical use and results. Methods Our handmade external fixator was applied for 52 patients with 56 fractures. Only 5% of the fractures were closed, non-comminuted extra-articular, and the other 51 fractures were more complex injuries. The mean follow up time was 9.3 months. At the end of the follow up, radiologic and functional assessment (DASH: Disability of arm, shoulder and hand and TAM: Total active motion was evaluated. Results All 56 fractures were united completely. None of the cases experienced pin loosening or reduction loss. Of the fractures, 8.9% malunited due to fracture complexity. The mean dash score was 3.76. TAM was excellent in 45% of the fractures; it was good in 7% and fair in 4%. Conclusions This type of handmade external fixator is simple, lightweight, and cheap. Furthermore, all implements are readily available in most operating fields. The probability of loosening has been greatly diminished because of the concrete like structure. Easy and fast assembly and good clinical and functional results are the other advantages of this technique. Due to the less complication and benefits, this technique could be used for many phalangeal and metacarpal fractures with confidence.

  15. EEG Negativity in Fixations Used for Gaze-Based Control: Toward Converting Intentions into Actions with an Eye-Brain-Computer Interface

    Science.gov (United States)

    Shishkin, Sergei L.; Nuzhdin, Yuri O.; Svirin, Evgeny P.; Trofimov, Alexander G.; Fedorova, Anastasia A.; Kozyrskiy, Bogdan L.; Velichkovsky, Boris M.

    2016-01-01

    We usually look at an object when we are going to manipulate it. Thus, eye tracking can be used to communicate intended actions. An effective human-machine interface, however, should be able to differentiate intentional and spontaneous eye movements. We report an electroencephalogram (EEG) marker that differentiates gaze fixations used for control from spontaneous fixations involved in visual exploration. Eight healthy participants played a game with their eye movements only. Their gaze-synchronized EEG data (fixation-related potentials, FRPs) were collected during game's control-on and control-off conditions. A slow negative wave with a maximum in the parietooccipital region was present in each participant's averaged FRPs in the control-on conditions and was absent or had much lower amplitude in the control-off condition. This wave was similar but not identical to stimulus-preceding negativity, a slow negative wave that can be observed during feedback expectation. Classification of intentional vs. spontaneous fixations was based on amplitude features from 13 EEG channels using 300 ms length segments free from electrooculogram contamination (200–500 ms relative to the fixation onset). For the first fixations in the fixation triplets required to make moves in the game, classified against control-off data, a committee of greedy classifiers provided 0.90 ± 0.07 specificity and 0.38 ± 0.14 sensitivity. Similar (slightly lower) results were obtained for the shrinkage Linear Discriminate Analysis (LDA) classifier. The second and third fixations in the triplets were classified at lower rate. We expect that, with improved feature sets and classifiers, a hybrid dwell-based Eye-Brain-Computer Interface (EBCI) can be built using the FRP difference between the intended and spontaneous fixations. If this direction of BCI development will be successful, such a multimodal interface may improve the fluency of interaction and can possibly become the basis for a new input device

  16. EEG Negativity in Fixations Used for Gaze-Based Control: Toward Converting Intentions into Actions with an Eye-Brain-Computer Interface

    Directory of Open Access Journals (Sweden)

    Sergei L. Shishkin

    2016-11-01

    Full Text Available We usually look at an object when we are going to manipulate it. Thus, eye tracking can be used to communicate intended actions. An effective human-machine interface, however, should be able to differentiate intentional and spontaneous eye movements. We report an electroencephalogram (EEG marker that differentiates gaze fixations used for control from spontaneous fixations involved in visual exploration. Eight healthy participants played a game with their eye movements only. Their gaze-synchronized EEG data (fixation-related potentials, FRPs were collected during game’s control-on and control-off conditions. A slow negative wave with a maximum in the parietooccipital region was present in each participant’s averaged FRPs in the control-on conditions and was absent or had much lower amplitude in the control-off condition. This wave was similar but not identical to stimulus-preceding negativity, a slow negative wave that can be observed during feedback expectation. Classification of intentional vs. spontaneous fixations was based on amplitude features from 13 EEG channels using 300 ms length segments free from electrooculogram contamination (200..500 ms relative to the fixation onset. For the first fixations in the fixation triplets required to make moves in the game, classified against control-off data, a committee of greedy classifiers provided 0.90 ± 0.07 specificity and 0.38 ± 0.14 sensitivity. Similar (slightly lower results were obtained for the shrinkage LDA classifier. The second and third fixations in the triplets were classified at lower rate. We expect that, with improved feature sets and classifiers, a hybrid dwell-based Eye-Brain-Computer Interface (EBCI can be built using the FRP difference between the intended and spontaneous fixations. If this direction of BCI development will be successful, such a multimodal interface may improve the fluency of interaction and can possibly become the basis for a new input device for

  17. A new 3-dimensional head fixation device for brain imaging

    International Nuclear Information System (INIS)

    Goto, Ryoi; Kawashima, Ryuta; Yoshioka, Seiro; Ono, Shuichi; Ito, Hiroshi; Sato, Kazunori; Akaizawa, Takashi; Koyama, Masamichi; Fukuda, Hiroshi

    1995-01-01

    We have developed a new head fixation device for studies of brain function. This device was designed to immobilize subject's heads during image scanning and to precisely reproduce the head position for two different imaging modalities such as MRI and PET. The device consists of a plastic frame, a pillow filled with beads of styrene foam, and a face mask of thermoplastic resin which was originally intended for application in radiotherapy. A bridge for biting was incorporated into the mask for stable fixation. The device enables immobilization of subject's heads with good reproducibility of position at the practical level. Our results indicate that this head fixation system is useful for fixation of head during activation studies using PET. (author)

  18. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  19. Distribution of nitrogen fixation and nitrogenase-like sequences amongst microbial genomes

    Science.gov (United States)

    2012-01-01

    Background The metabolic capacity for nitrogen fixation is known to be present in several prokaryotic species scattered across taxonomic groups. Experimental detection of nitrogen fixation in microbes requires species-specific conditions, making it difficult to obtain a comprehensive census of this trait. The recent and rapid increase in the availability of microbial genome sequences affords novel opportunities to re-examine the occurrence and distribution of nitrogen fixation genes. The current practice for computational prediction of nitrogen fixation is to use the presence of the nifH and/or nifD genes. Results Based on a careful comparison of the repertoire of nitrogen fixation genes in known diazotroph species we propose a new criterion for computational prediction of nitrogen fixation: the presence of a minimum set of six genes coding for structural and biosynthetic components, namely NifHDK and NifENB. Using this criterion, we conducted a comprehensive search in fully sequenced genomes and identified 149 diazotrophic species, including 82 known diazotrophs and 67 species not known to fix nitrogen. The taxonomic distribution of nitrogen fixation in Archaea was limited to the Euryarchaeota phylum; within the Bacteria domain we predict that nitrogen fixation occurs in 13 different phyla. Of these, seven phyla had not hitherto been known to contain species capable of nitrogen fixation. Our analyses also identified protein sequences that are similar to nitrogenase in organisms that do not meet the minimum-gene-set criteria. The existence of nitrogenase-like proteins lacking conserved co-factor ligands in both diazotrophs and non-diazotrophs suggests their potential for performing other, as yet unidentified, metabolic functions. Conclusions Our predictions expand the known phylogenetic diversity of nitrogen fixation, and suggest that this trait may be much more common in nature than it is currently thought. The diverse phylogenetic distribution of nitrogenase

  20. Distribution of nitrogen fixation and nitrogenase-like sequences amongst microbial genomes

    Directory of Open Access Journals (Sweden)

    Dos Santos Patricia C

    2012-05-01

    Full Text Available Abstract Background The metabolic capacity for nitrogen fixation is known to be present in several prokaryotic species scattered across taxonomic groups. Experimental detection of nitrogen fixation in microbes requires species-specific conditions, making it difficult to obtain a comprehensive census of this trait. The recent and rapid increase in the availability of microbial genome sequences affords novel opportunities to re-examine the occurrence and distribution of nitrogen fixation genes. The current practice for computational prediction of nitrogen fixation is to use the presence of the nifH and/or nifD genes. Results Based on a careful comparison of the repertoire of nitrogen fixation genes in known diazotroph species we propose a new criterion for computational prediction of nitrogen fixation: the presence of a minimum set of six genes coding for structural and biosynthetic components, namely NifHDK and NifENB. Using this criterion, we conducted a comprehensive search in fully sequenced genomes and identified 149 diazotrophic species, including 82 known diazotrophs and 67 species not known to fix nitrogen. The taxonomic distribution of nitrogen fixation in Archaea was limited to the Euryarchaeota phylum; within the Bacteria domain we predict that nitrogen fixation occurs in 13 different phyla. Of these, seven phyla had not hitherto been known to contain species capable of nitrogen fixation. Our analyses also identified protein sequences that are similar to nitrogenase in organisms that do not meet the minimum-gene-set criteria. The existence of nitrogenase-like proteins lacking conserved co-factor ligands in both diazotrophs and non-diazotrophs suggests their potential for performing other, as yet unidentified, metabolic functions. Conclusions Our predictions expand the known phylogenetic diversity of nitrogen fixation, and suggest that this trait may be much more common in nature than it is currently thought. The diverse phylogenetic

  1. Types of Heart Failure

    Science.gov (United States)

    ... Introduction Types of Heart Failure Classes of Heart Failure Heart Failure in Children Advanced Heart Failure • Causes and ... and procedures related to heart disease and stroke. Heart Failure Questions to Ask Your Doctor Use these questions ...

  2. Prediction of line failure fault based on weighted fuzzy dynamic clustering and improved relational analysis

    Science.gov (United States)

    Meng, Xiaocheng; Che, Renfei; Gao, Shi; He, Juntao

    2018-04-01

    With the advent of large data age, power system research has entered a new stage. At present, the main application of large data in the power system is the early warning analysis of the power equipment, that is, by collecting the relevant historical fault data information, the system security is improved by predicting the early warning and failure rate of different kinds of equipment under certain relational factors. In this paper, a method of line failure rate warning is proposed. Firstly, fuzzy dynamic clustering is carried out based on the collected historical information. Considering the imbalance between the attributes, the coefficient of variation is given to the corresponding weights. And then use the weighted fuzzy clustering to deal with the data more effectively. Then, by analyzing the basic idea and basic properties of the relational analysis model theory, the gray relational model is improved by combining the slope and the Deng model. And the incremental composition and composition of the two sequences are also considered to the gray relational model to obtain the gray relational degree between the various samples. The failure rate is predicted according to the principle of weighting. Finally, the concrete process is expounded by an example, and the validity and superiority of the proposed method are verified.

  3. Effects of tissue fixation and dehydration on tendon collagen nanostructure.

    Science.gov (United States)

    Turunen, Mikael J; Khayyeri, Hanifeh; Guizar-Sicairos, Manuel; Isaksson, Hanna

    2017-09-01

    Collagen is the most prominent protein in biological tissues. Tissue fixation is often required for preservation or sectioning of the tissue. This may affect collagen nanostructure and potentially provide incorrect information when analyzed after fixation. We aimed to unravel the effect of 1) ethanol and formalin fixation and 2) 24h air-dehydration on the organization and structure of collagen fibers at the nano-scale using small and wide angle X-ray scattering. Samples were divided into 4 groups: ethanol fixed, formalin fixed, and two untreated sample groups. Samples were allowed to air-dehydrate in handmade Kapton pockets during the measurements (24h) except for one untreated group. Ethanol fixation affected the collagen organization and nanostructure substantially and during 24h of dehydration dramatic changes were evident. Formalin fixation had minor effects on the collagen organization but after 12h of air-dehydration the spatial variation increased substantially, not evident in the untreated samples. Generally, collagen shrinkage and loss of alignment was evident in all samples during 24h of dehydration but the changes were subtle in all groups except the ethanol fixed samples. This study shows that tissue fixation needs to be chosen carefully in order to preserve the features of interest in the tissue. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Plant, Microbiome, and Biogeochemistry: Quantifying moss-associated N fixation in Alaska

    Science.gov (United States)

    Stuart, J.; Mack, M. C.; Holland Moritz, H.; Fierer, N.; McDaniels, S.; Lewis, L.

    2017-12-01

    The future carbon (C) sequestration potential of the Arctic and boreal zones, currently the largest terrestrial C sink globally, is linked to nitrogen (N) cycling and N availability vis-a-vis C accumulation and plant species composition. Pristine environments in Alaska have low anthropogenic N deposition (<1 kg N ha-1 yr-1), and the main source of new N to these ecosystems is through previously overlooked N-fixation from microbial communities on mosses. Despite the importance of moss associated N-fixation, the relationship between moss species, microbial communities, and fixation rates remains ambiguous. In the summer of 2016, the fixation rates of 20 moss species from sites around both Fairbanks and Toolik Lake were quantified using 15N2 incubations. Subsequently, the microbial community and moss genome of the samples were also analyzed by collaborators. The most striking result is that all sampled moss genera fixed N, including well-studied feather mosses such as Hylocomium splendens and Pleurozium schreberi as well as less common but ecologically relevant mosses such as Aulacomnium spp., Dicranum spp., Ptilium crista-castrensis, and Tomentypnum nitens. Across all samples, preliminary fixation rates ranged from 0.004-19.994 µg N g-1 moss d-1. Depending upon percent cover, moss-associated N fixation is the largest input of new N to the ecosystem. Given this, linking variation in N-fixation rates to microbial and moss community structures can be helpful in predicting future trends of C and N cycling in northern latitudes. Vegetation changes, alterations in downstream biogeochemical N processes, and anthropogenic N deposition could all interact with or alter moss associated N-fixation, thereby changing ecosystem N inputs. Further elucidation of the species level signal in N-fixation rates and microbial community will augment our knowledge of N cycling in northern latitudes, both current and future.

  5. Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience.

    Science.gov (United States)

    Yu, Ke-He; Hong, Jian-Jun; Guo, Xiao-Shan; Zhou, Dong-Sheng

    2015-09-22

    The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18-54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.

  6. Femoral fractures : indications an[d] biomechanics of external fixation

    NARCIS (Netherlands)

    A.H. Broekhuizen (Tom); B. van Linge

    1988-01-01

    textabstractInternal fixation can be carried out in various ways. For femoral shaft fractures, an (interlocking) nail is becoming increasingly popular, instead of open realignment of the fracture. External fixation, which has become a generally accepted method of treating fractures of the lower

  7. Evaluation of Transsyndesmotic Fixation and Primary Deltoid Ligament Repair in Ankle Fractures With Suspected Combined Deltoid Ligament Injury.

    Science.gov (United States)

    Wu, Kai; Lin, Jian; Huang, Jianhua; Wang, Qiugen

    2018-04-13

    The present prospective study examined the utility of the intraoperative tap test/technique for distal tibiofibular syndesmosis in the diagnosis of deltoid ligament rupture and compared the outcomes of transsyndesmotic fixation to deltoid ligament repair with suture anchor. This diagnostic technique was performed in 59 ankle fractures with suspected deltoid ligament injury. The width of the medial clear space of 59 cases was evaluated to assess the sensitivity and specificity. Those with deltoid ligament rupture were randomly assigned to 2 groups and treated with deltoid ligament repair with a suture anchor or with syndesmosis screw fixation. All the patients were assessed with the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, short-form 36-item questionnaire (SF-36), and visual analog scale (VAS). The tap test was positive in 53 cases. However, surgical exploration demonstrated that 51 cases (86.4%) had a combined deltoid ligament injury and fracture. The sensitivity and specificity of the tap test was 100.0% and 75.0%, respectively. Finally, 26 cases (96.3%) in the syndesmosis screw group and 22 (91.7%) in the deltoid repair group were followed up. No statistically significant differences were found in the AOFAS ankle-hindfoot scale score, SF-36 score, or VAS score between the 2 groups. The malreduction rate in the syndesmosis screw group was 34.6% and that in the deltoid repair group was 9.09%. The tap test is an intraoperative diagnostic method to use to evaluate for deltoid ligament injury. Deltoid ligament repair with a suture anchor had good functional and radiologic outcomes comparable to those with syndesmotic screw fixation but has a lower malreduction rate. We did not encounter the issue of internal fixation failure or implant removal. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Tricortical cervical inter-body screw fixation.

    Directory of Open Access Journals (Sweden)

    Goel A

    1997-01-01

    Full Text Available A new tricortical method of screw implantation for anterior cervical interbody plate fixation is described. The screws are placed obliquely such that they engage the anterior cortex of the body and traverse through the cortices adjoining the disc space. By this method the screws not only hold the plate firmly with a tricortical purchase, but by virtue of their course stabilize the two adjoining vertebral bodies by themselves. Sixteen patients were treated by this method. In three of these cases only tricortical screws without the metal plate were used for fixation. The advantages of the technique are discussed.

  9. Internal fixation of mandibular angle fractures: a meta-analysis.

    Science.gov (United States)

    Regev, Eran; Shiff, Jacob S; Kiss, Alex; Fialkov, Jeffrey A

    2010-06-01

    The degree of rigidity of internal fixation required for the treatment of mandibular angle fractures has long been at the center of debate in the literature. A statistical comparison between rigid fixation and monocortical fixation has been difficult because of multiple terms, definitions, and technical variations. The purpose of this study was to use the meta-analysis tool to combine information from multiple studies and to compare complication rates for different fixation methods. An English language literature search was conducted for articles on mandibular angle fractures. Information was collected on four variables of interest: compression/noncompression technique, monocortical/bicortical screws, number of plates, and location of plates. Five outcome rates were analyzed: infection, reoperation, hardware removal, malunion, and nonunion. Meta-analyses were run using Comprehensive Meta Analysis, version 2.2.03. Twenty-four studies with relevant data on the variables and outcomes of interest met the inclusion criteria. Significantly higher rates of infection, reoperation, and hardware removal were found for compression compared with noncompression, two plates compared with one plate, and for plates located on both the inferior and superior borders as compared with superior or inferior only. There were also significantly higher infection rates for bicortical screws compared with monocortical screws and higher malunion rates for compression compared with noncompression plating techniques. The results of this meta-analysis found lower complication rates with the use of noncompression, monocortical, and single-plate fixation, supporting the trend toward a single, superiorly placed, monocortical miniplate for fixation of mandibular angle fractures.

  10. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Bakhru, Prashant [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Park, Brian [Albert Einstein College of Medicine, Bronx, NY (United States); Umans, Hilary [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States); DiFelice, Gregory S. [Hospital for Special Surgery, New York, NY (United States); Tobin, Keith [Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States)

    2011-06-15

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  11. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    International Nuclear Information System (INIS)

    Bakhru, Prashant; Park, Brian; Umans, Hilary; DiFelice, Gregory S.; Tobin, Keith

    2011-01-01

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  12. [Clinical application of atlas translaminar screws fixation in treatment of atlatoaxial instability].

    Science.gov (United States)

    Wang, Guoyou; Fu, Shijie; Shen, Huarui; Guan, Taiyuan; Xu, Ping

    2013-10-01

    To explore the effectiveness of fixation of atlas translaminar screws in the treatment of atlatoaxial instability. A retrospective analysis was made on the clinical data of 32 patients with atlatoaxial instability treated with atlantoaxial trans-pedicle screws between March 2007 and August 2009. Of them, 7 patients underwent atlas translaminar screws combined with axis transpedicle screws fixation because of fracture types, anatomic variation, and intraoperative reason, including 5 males and 2 females with an average age of 48.2 years (range, 35-69 years). A total of 9 translaminar screws were inserted. Injury was caused by traffic accident in 4 cases, falling from height in 2 cases, and crushing in 1 case. Two cases had simple odontoid fracture (Anderson type II), and 5 cases had odontoid fracture combined with other injuries (massa lateralis atlantis fracture in 2, atlantoaxial dislocation in 1, and Hangman fracture in 2). The interval between injury and operation was 4-9 days (mean, 6 days). The preoperative Japanese Orthopaedic Association (JOA) score was 8.29 +/- 1.60. The X-ray films showed good position of the screws. Healing of incision by first intention was obtained, and no patient had injuries of the spinal cord injury, nerve root, and vertebral artery. Seven cases were followed up 9-26 months (mean, 14 months). Good bone fusion was observed at 8 months on average (range, 6-11 months). No loosening, displacement, and breakage of internal fixation, re-dislocation and instability of atlantoaxial joint, or penetrating of pedicle screw into the spinal canal and the spinal cord occurred. The JOA score was significantly improved to 15.29 +/- 1.38 at 6 months after operation (t = 32.078, P = 0.000). Atlas translaminar screws fixation has the advantages of firm fixation, simple operating techniques, and relative safety, so it may be a remedial measure of atlatoaxial instability.

  13. Influence of removal of invisible fixation on the saccadic and manual gap effect.

    Science.gov (United States)

    Ueda, Hiroshi; Takahashi, Kohske; Watanabe, Katsumi

    2014-01-01

    Saccadic and manual reactions to a peripherally presented target are facilitated by removing a central fixation stimulus shortly before a target onset (the gap effect). The present study examined the effects of removal of a visible and invisible fixation point on the saccadic gap effect and the manual gap effect. Participants were required to fixate a central fixation point and respond to a peripherally presented target as quickly and accurately as possible by making a saccade (Experiment 1) or pressing a corresponding key (Experiment 2). The fixation point was dichoptically presented, and visibility was manipulated by using binocular rivalry and continuous flash suppression technique. In both saccade and key-press tasks, removing the visible fixation strongly quickened the responses. Furthermore, the invisible fixation, which remained on the display but suppressed, significantly delayed the saccadic response. Contrarily, the invisible fixation had no effect on the manual task. These results indicate that partially different processes mediate the saccadic gap effect and the manual gap effect. In particular, unconscious processes might modulate an oculomotor-specific component of the saccadic gap effect, presumably via subcortical mechanisms.

  14. Application of monorail fixator for femoral gap nonunion.

    Science.gov (United States)

    Agrawal, Hemendra-Kumar; Jaiman, Ashish; Khatkar, Vipin; Sharma, Vinod-Kumar

    2014-01-01

    Difficult femoral nonunion takes account of infective nonunion and aseptic gap nonunion. Limb length discrepancy and nonunion need to be tackled simultaneously. Conventionally Ilizarov ring fixator is in vogue but it has some limitations. To overcome these, monorail fixator is an effective alternative. Persistent good results can be obtained if we can get a perfect anatomical alignment and good regeneration.

  15. Effects of Long-term Fertilization on Potassium Fixation Capacity in Brown Soil

    Science.gov (United States)

    Li, Na; Guo, Chunlei; Wang, Yue; Gao, Tianyi; Yang, Jinfeng; Han, Xiaori

    2018-01-01

    This study concentrated on the research of features of fixation. The objective of this study was to provide theoretical foundation of rational application of potassium fertilizer along with improving fertilizer availability ratio. A 32 years long-term experiment was conducted to evaluate the effects of fertilizer application on potassium changes and the factors affecting K fixation on brown soil by simulation in laboratory. When the concentration of exogenous potassium was in range of 400∼4000 mg·kg-1, potassium fixation capacity increased along with the rise of concentration of exogenous potassium, whereas K fixation rate reduced; Compared with no-potassium fertilizer, application of potassium fertilizer and organic fertilizer reduced soil potassium fixation capacity. Potassium rate and fixation-release of potassium character in soil should be taken into comprehensive consideration for rational fertilization to maintain or improve soil fertility for increasing potassium fertilizers efficiency in agriculture.

  16. Biomechanical considerations in slipped capital femoral epiphysis and insights into prophylactic fixation.

    Science.gov (United States)

    Leblanc, E; Bellemore, J M; Cheng, T; Little, D G; Birke, O

    2017-04-01

    Slipped capital femoral epiphysis (SCFE) is a deformity of the proximal femur secondary to widened and unstable physis. In stabilising the slip, gold standard treatments stop growth and involve premature physeal closure, which prevents the remodelling of the acquired deformity and creates a leg length discrepancy that may be significant in younger patients. We measured the impact of placing threaded screws across the proximal femoral physis by measuring the centre-trochanteric distance (CTD) and articulo-trochanteric distance (ATD) in participants with or without prophylactic fixation. We then compared the mechanical performance of static (stainless and titanium cannulated Synthes screws) and potentially growing implants (Synthes SCFE screw and Pega Medical Free Gliding screw) in a validated synthetic bone model. In the review of 30 non-fixed and 60 fixated hips over a mean follow-up of 1.9 years, we have noted a significant difference in pre/post CTD and ATD, as well as the change in CTD and ATD over time. In the biomechanical study, the newer implants allowing growth (Synthes SCFE screw and Pega Medical Free Gliding screw) were both shown to be at least non-inferior. The primary deformity of a SCFE in itself alters hip mechanics. Also, as confirmed in this study, there is a secondary deformity that is created by static fixation and relative trochanteric overgrowth. To help remodel mild deformities and prevent secondary trochanteric overgrowth, growing implants seem to be non-inferior to the more standard means of fixation in static testing.

  17. Alignment After Intramedullary Nailing of Distal Tibia Fractures Without Fibula Fixation.

    Science.gov (United States)

    De Giacomo, Anthony F; Tornetta, Paul

    2016-10-01

    To evaluate the efficacy of intramedullary nailing of distal tibia fractures using modern techniques, without fibula fixation, in obtaining and maintaining alignment. Retrospective case review. Level-I academic trauma center. One hundred thirty-two consecutive patients with distal tibia fractures. Intramedullary nail of distal tibia fracture, without fibula fixation, was performed in consecutive patients using modern reduction techniques. Malalignment and malunion were defined as >5 degrees of varus/valgus angulation or anterior/posterior angulation on the initial postoperative or final anteroposterior and lateral x-rays. There were 122 consecutive patients (86 men and 36 women) 16-93 years of age (average, 43 years) with 36 (30%) open and 85 (70%) closed fractures with complete follow-up. Mechanism of injury did not predict the presence or level of fibula fracture. Upon presentation, varus/valgus and procurvatum/recurvatum angulation was greatest when the fibula was fractured at the level of the tibia fracture (P = 0.001 and 0.028). The most common intraoperative reduction aids were nailing in relative extension, transfixion external fixation, and clamps at the fracture site. The OTA fracture type or level/presence of fibula fracture did not influence malalignment (P = 0.86 and 0.66), malunion (P = 0.81 and 0.79), or the change in alignment during union, which averaged 0.9 degrees. We found an overall low rate of both malalignment (2%) and malunion (3%) after intramedullary nailing of distal tibial shaft fracture without fibula fixation. We conclude that when modern nailing techniques are used, which allow for confirmation of reduction by visualization in fluoroscopy, from nail placement to distal interlocking, fibula fixation is not necessary to obtain or maintain alignment. Furthermore, standard 2 medial to lateral screws distally afford adequate stability to hold the reduction during union with a 0.9-degree difference in the initial postoperative and final

  18. The role of minimally invasive plate osteosynthesis in rib fixation : A review

    NARCIS (Netherlands)

    Bemelman, Michael; Van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950's, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation.

  19. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    Science.gov (United States)

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  20. Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection

    Directory of Open Access Journals (Sweden)

    Engin Çetin

    2015-01-01

    Full Text Available Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod. In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P<0.01. Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P<0.005. Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.

  1. Eye movements and serial memory for visual-spatial information: does time spent fixating contribute to recall?

    Science.gov (United States)

    Saint-Aubin, Jean; Tremblay, Sébastien; Jalbert, Annie

    2007-01-01

    This research investigated the nature of encoding and its contribution to serial recall for visual-spatial information. In order to do so, we examined the relationship between fixation duration and recall performance. Using the dot task--a series of seven dots spatially distributed on a monitor screen is presented sequentially for immediate recall--performance and eye-tracking data were recorded during the presentation of the to-be-remembered items. When participants were free to move their eyes at their will, both fixation durations and probability of correct recall decreased as a function of serial position. Furthermore, imposing constant durations of fixation across all serial positions had a beneficial impact (though relatively small) on item but not order recall. Great care was taken to isolate the effect of fixation duration from that of presentation duration. Although eye movement at encoding contributes to immediate memory, it is not decisive in shaping serial recall performance. Our results also provide further evidence that the distinction between item and order information, well-established in the verbal domain, extends to visual-spatial information.

  2. Relation between sensitization and failures of welded joints at furnaces of Cienfuegos refinery

    International Nuclear Information System (INIS)

    Dominguez, H.; Menendez, C.M.; Sendoya, F.A.

    1992-01-01

    This work is concerned about the possible relation between sensitization and failures of welded joints at furnaces of Cienfuegos Refinery. This failures were detected in austenitic pipes by hydraulic testing. For determined the tendency to sensitization of heat affected zones (HAZ) of welded joints and piping, have been used standardized test methods AM and AMU (GOST 6032-89). In addition, the Electrochemical Potentiokinetic Reactivation (EPR) test was employed to quantity the tendency to intergranular corrosion. It was found that degree of sensitization was higher at HAZ and as a possible explanation is proposed the overheating during welding

  3. Nitrate reductase and nitrogenase activities in relation to N-uptake from soil, 15N-fertilizer and symbiotic fixation in soybean (Glycine max)

    International Nuclear Information System (INIS)

    Ruschel, A.P.; Saito, S.M.T.; Vose, P.B.

    1980-01-01

    Nitrate reductase (NRA) and nitrogenase (ARA) activities were evaluated in relation to nitrogen in the plant from soil (NFS), fertilizer (NFF) and symbiotic fixation (NFN 2 ) to study the pattern of utilization of nitrogen in nodulated and non nodulated soybean, 35, 55 and 75 days after planting. Three levels of ( 15 NH 4 ) 2 SO 4 - added to soil were used (0 - 25 and 50 kg N/ha), being the experiment conducted in the greenhouse, with a split plot statistical design and 4 replications. Maximum levels of RNA and ARA occurred 55 days after planting. Addition of 50 kg N/ha decreased NRA at all harvesting time studied; and nodule ARA only 75 days after planting. By that time the nodulated isoline showed higher NRA than the non nodulated one, the NFS and NFF of the isolines were not different 35 and 55 days after planting, but decreased at the last harvest, especially in nodulated soybean. Symbiotic N 2 -fixation increased plant-N after 55 days growth, contribution about 65% of plant-N in the period between 55 and 75 days after planting. Nodulated plant showed higher N than non nodulated, a sinergistic effect of the three sources of N studied on N increase of nodulated plants was observed. (Author) [pt

  4. The analysis of the influence of fractal structure of stimuli on fractal dynamics in fixational eye movements and EEG signal

    Science.gov (United States)

    Namazi, Hamidreza; Kulish, Vladimir V.; Akrami, Amin

    2016-05-01

    One of the major challenges in vision research is to analyze the effect of visual stimuli on human vision. However, no relationship has been yet discovered between the structure of the visual stimulus, and the structure of fixational eye movements. This study reveals the plasticity of human fixational eye movements in relation to the ‘complex’ visual stimulus. We demonstrated that the fractal temporal structure of visual dynamics shifts towards the fractal dynamics of the visual stimulus (image). The results showed that images with higher complexity (higher fractality) cause fixational eye movements with lower fractality. Considering the brain, as the main part of nervous system that is engaged in eye movements, we analyzed the governed Electroencephalogram (EEG) signal during fixation. We have found out that there is a coupling between fractality of image, EEG and fixational eye movements. The capability observed in this research can be further investigated and applied for treatment of different vision disorders.

  5. Biomechanical analysis of titanium fixation plates and screws in ...

    African Journals Online (AJOL)

    Conclusions: It was concluded that the use of double 4-hole straight plates provided the sufficient stability on the osteotomy site when compared with the other rigid fixation methods used in this study. Key words: Bone plates, bone screws, finite element analysis, jaw fixation techniques, mandible, mandibular osteotomy ...

  6. Management of simple (types A and B) closed tibial shaft fractures using percutaneous lag-screw fixation and Ilizarov external fixation in adults.

    Science.gov (United States)

    El-Sayed, Mohamed; Atef, Ashraf

    2012-10-01

    Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.

  7. Laser-assisted fixation of a nitinol stapes prosthesis.

    Science.gov (United States)

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Using synthetic biology to distinguish and overcome regulatory and functional barriers related to nitrogen fixation.

    Directory of Open Access Journals (Sweden)

    Xia Wang

    Full Text Available Biological nitrogen fixation is a complex process requiring multiple genes working in concert. To date, the Klebsiella pneumoniae nif gene cluster, divided into seven operons, is one of the most studied systems. Its nitrogen fixation capacity is subject to complex cascade regulation and physiological limitations. In this report, the entire K. pneumoniae nif gene cluster was reassembled as operon-based BioBrick parts in Escherichia coli. It provided ~100% activity of native K. pneumoniae system. Based on the expression levels of these BioBrick parts, a T7 RNA polymerase-LacI expression system was used to replace the σ(54-dependent promoters located upstream of nif operons. Expression patterns of nif operons were critical for the maximum activity of the recombinant system. By mimicking these expression levels with variable-strength T7-dependent promoters, ~42% of the nitrogenase activity of the σ(54-dependent nif system was achieved in E. coli. When the newly constructed T7-dependent nif system was challenged with different genetic and physiological conditions, it bypassed the original complex regulatory circuits, with minor physiological limitations. Therefore, we have successfully replaced the nif regulatory elements with a simple expression system that may provide the first step for further research of introducing nif genes into eukaryotic organelles, which has considerable potentials in agro-biotechnology.

  9. Failure after osteosynthesis of trochanteric fractures. Where is the limit of osteoporosis?

    Science.gov (United States)

    Konstantinidis, L; Papaioannou, C; Blanke, P; Hirschmüller, A; Südkamp, N P; Helwig, P

    2013-10-01

    The aim of this study is to identify osteoporosis values, beyond which there is a high risk of osteosynthesis failure. Bone mineral density (BMD) of 30 cadaveric femora with a pertrochanteric fracture osteotomy was correlated to the risk of cut out after osteosynthesis on a biomechanical testing approach. For a BMD less than 250 mg/cm(3), there is a high risk of fixation failure after surgical treatment of pertrochanteric fractures. This value can be regarded as a reference value for future experimental and clinical studies. Despite continuous modification of intramedullary load carriers for the surgical stabilization of trochanteric fractures, cut out remains the most frequent complication. The aim of this experimental study was to identify threshold osteoporosis values, beyond which there is a high risk of osteosynthesis failure. Bone mineral density (BMD) of 30 cadaveric femora was recorded for the femoral head by QCT measurement. Subsequently, a standardized osteotomy mimicking an unstable trochanteric type fracture was stabilized by intramedullary nailing. The constructs were loaded axially at a force of 2,100 N up to 20,000 cycles. Cut out at the femoral head was documented by radiograph. Statistical evaluation of the cohort group was performed by calculation of relative risk in relation to the BMD values. In total, there were six cases of cut out after 10,000 cycles. The incidence of cut out for BMD less than 250 mg/cm(3) was 0.55 (5 of 9) and for BMD greater than 250 mg/cm(3), it was 0.05 (1 of 21). Therefore, the relative risk of cut out for BMD 250 mg/cm(3). After 20,000 cycles, an additional test caused one cut out (relative risk of cut out for a BMD fractures. Although this value is based on an experimental in vitro study design with all its associated limitations, it can be regarded as a reference value for future experimental and clinical studies.

  10. Cognitive reactivity to success and failure relate uniquely to manic and depression tendencies and combine in bipolar tendencies.

    Science.gov (United States)

    Raes, Filip; Ghesquière, Ine; Van Gucht, Dinska

    2012-01-01

    The present study examined simultaneously the relations between cognitive reactivity to success and failure, on the one hand, and depression, manic, and bipolar tendencies, on the other hand. Participants (161 students) completed measures of success and failure reactivity, current manic and depressive symptoms, and tendencies towards depression, mania, and bipolarity. Results showed that respondents with a greater tendency towards depression evidenced greater (negative) reactivity to failure, whereas those with a greater tendency toward mania evidenced greater (positive) reactivity to success. Depression vulnerability was unrelated to success reactivity, and manic vulnerability was unrelated to failure reactivity. Tendencies toward bipolarity correlated significantly with both failure and success reactivity in a negative and positive manner, respectively. These findings add to the growing body of literature, suggesting that different features or cognitive tendencies are related to depression vulnerability versus manic vulnerability and imply that these "mirrored" cognitive features both form part of vulnerability to bipolar disorder.

  11. Cognitive Reactivity to Success and Failure Relate Uniquely to Manic and Depression Tendencies and Combine in Bipolar Tendencies

    Directory of Open Access Journals (Sweden)

    Filip Raes

    2012-01-01

    Full Text Available The present study examined simultaneously the relations between cognitive reactivity to success and failure, on the one hand, and depression, manic, and bipolar tendencies, on the other hand. Participants (161 students completed measures of success and failure reactivity, current manic and depressive symptoms, and tendencies towards depression, mania, and bipolarity. Results showed that respondents with a greater tendency towards depression evidenced greater (negative reactivity to failure, whereas those with a greater tendency toward mania evidenced greater (positive reactivity to success. Depression vulnerability was unrelated to success reactivity, and manic vulnerability was unrelated to failure reactivity. Tendencies toward bipolarity correlated significantly with both failure and success reactivity in a negative and positive manner, respectively. These findings add to the growing body of literature, suggesting that different features or cognitive tendencies are related to depression vulnerability versus manic vulnerability and imply that these “mirrored” cognitive features both form part of vulnerability to bipolar disorder.

  12. Internal versus external fixation of the anterior component in unstable fractures of the pelvic ring: pooled results from a systematic review.

    Science.gov (United States)

    Wardle, B; Eslick, G D; Sunner, P

    2016-10-01

    Improving reduction of the pelvic ring improves long-term functional outcomes for patients. It has been demonstrated that posterior internal fixation is necessary to adequately control fractures to the posterior ring and there is evidence that supplementing this with fixation of the anterior ring improves stability. It is accepted that internal fixation provides greater stability than external fixation of the anterior ring but long-term differences in radiographic and functional outcomes have not yet been quantified. A search of electronic databases, reference lists and review articles from 1989 to 2015 yielded 18 studies (n = 884) that met our inclusion criteria. We included studies that discussed pelvic ring injuries in adults, reported functional or radiological outcomes or complications by anterior ring intervention and exceeded 14 patients. We excluded biomechanical and cadaver studies. Internal fixation of the anterior pelvic ring had better functional and radiographic outcomes. Residual displacement of >10 mm was less common with internal fixation (ER 0.12, 95 % CI 0.06-0.24) than external fixation (ER 0.31, 95 % CI 0.11-0.62). Unsatisfactory outcomes also occurred at a lower rate (ER 0.09, 95 % CI 0.03-0.22) compared to external fixation (ER 0.32, 95 % CI 0.18-0.50). Losses of reduction (ER 0.02, 95 % CI 0.01-0.04 versus ER 0.07, 95 % CI 0.02-0.21), malunions (ER 0.03, 95 % CI 0.01-0.08 versus ER 0.07, 95 % CI 0.02-0.21) and delayed/non-unions (ER 0.02, 95 % CI 0.01-0.05 versus ER 0.04, 95 % CI 0.02-0.07). Internal fixation of the anterior pelvic ring as supplementary fixation for unstable injuries to the pelvic ring appears to result in better radiographic and functional outcomes as well as fewer complications. However, data that separated outcomes and complications in relation to interventions of the anterior pelvic ring were limited. More studies looking specifically at outcomes in relation to the type of anterior ring intervention are

  13. Biological N2 fixation mainly controlled by Sphagnum tissue N:P ratio in ombrotrophic bogs

    Science.gov (United States)

    Zivkovic, Tatjana; Moore, Tim R.

    2017-04-01

    :P ratio. We found that 65% of the variance in the increase of N2-fixation activity was explained by the decrease in N:P ratio in hollows (n = 73) but only about 20% in hummocks (n = 78). Changes in neither N or P concentration alone explained the increase in N2-fixation better than N:P ratio. We interpret that the difference between hollows and hummocks results from the availability of moisture that further limits N2-fixation. When moisture is not a limiting factor, i.e. in hollows, N:P ratio will be the best predictor of N2-fixation in bogs. Both studies suggest that the relative P availability to Sphagnum-associated diazotrophs, measured as a tissue N:P ratio, best describes N2-fixation activity in bogs, especially ones exposed to larger N deposition.

  14. Operative Fixation Options for Elective and Diabetic Ankle Arthrodesis.

    Science.gov (United States)

    Ramanujam, Crystal L; Stapleton, John J; Zgonis, Thomas

    2017-07-01

    Ankle arthrodesis remains one of the most definitive treatment options for end-stage arthritis, paralysis, posttraumatic and postinfectious conditions, failed total ankle arthroplasty, and severe deformities. The general aims of ankle arthrodesis are to decrease pain and instability, correct the accompanying deformity, and create a stable plantigrade foot. Several surgical approaches have been reported for ankle arthrodesis with internal fixation options. External fixation has also evolved for ankle arthrodesis in certain clinical scenarios. This article provides a comprehensive analysis of midterm to long-term outcomes for ankle arthrodesis using internal and/or external fixation each for elective and diabetic conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Use of locking plates for fixation of the greater trochanter in patients with hip replacement

    Directory of Open Access Journals (Sweden)

    Allison K. Tetreault, BA

    2016-12-01

    Conclusions: Locking plate technology is a successful method of fixation of the greater trochanter in patients with THA. Postoperative trochanteric pain and reoperation for hardware-related issues remain a challenge.

  16. External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients

    Science.gov (United States)

    Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li

    2016-01-01

    The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765

  17. Culture-Negative Infection After Operative Fixation of Fractures.

    Science.gov (United States)

    Gitajn, Ida L; Heng, Marilyn; Weaver, Michael J; Ehrlichman, Lauren K; Harris, Mitchel B

    2016-10-01

    (1) Compare the outcomes of patients with orthopaedic trauma with culture-negative infection with those with pathogens identified; (2) identify the incidence of culture-negative infection and describe the common characteristics. Retrospective study. Two level 1 trauma centers. A total of 391 patients 16 years of age or older who underwent irrigation and debridement for surgical site infection after having undergone fracture fixation were included. Patients underwent irrigation and debridement with cultures, and antibiotic therapy was initiated. Treatment failure due to unsuccessful eradication of infection and time to union. We found 9% incidence of culture-negative infection. Approximately one-third of patients in both groups went on to have treatment failure (25% of pathogen-specific infections, 38% of culture-negative infections, P = 0.15), and there was no difference between the 2 groups with regard to time to union (22 vs. 24 weeks, P = 0.55). More than one-third of patients required subsequent reconstructive procedure and 5% of patients in each group required amputation to control their infection. There was no difference between the groups with respect to the use of antibiotics before intervention and culture. This study confirms the devastating effect that postoperative infections can have and suggests that, with clinical sign of infection, negative cultures do not portend a better prognosis. These entities should be treated in a similar manner to infections with positive cultures. Furthermore, we believe that future studies should not strictly rely on the presence of positive intraoperative cultures. Consensus as to what constitutes a clinical infection, in the absence of positive cultures, is needed. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  18. Extent and Morbidity of Lateralization of a Trochanteric Fixation Nail Blade.

    Science.gov (United States)

    Sandifer, Phillip A; Hulick, Robert M; Graves, Matthew L; Spitler, Clay A; Russell, George V; Hydrick, Josie M; Jones, LaRita C; Bergin, Patrick F

    2017-09-01

    This study examined the incidence and risk factors associated with lateral helical blade migration and trochanteric pain with the trochanteric fixation nail. A retrospective review was performed of 141 cases of pertrochanteric femur fracture treated with a trochanteric fixation nail at a level I trauma center over a period of 42 months. Exclusion criteria included follow-up of less than 60 days, preexisting osteonecrosis of the femoral head, and prophylactic trochanteric fixation nail treatment. Patient demographics, operative findings, and radiographic findings were recorded. Medical records were reviewed to identify symptomatic hardware. Overall, 27 patients (19.1%) were symptomatic, and 3 (2.1%) required revision surgery for blade prominence. Of the patients, 42 (30%) had lateralization of greater than 1 cm, and 16 of these (38.1%) were symptomatic (Pfractures showing lateralization of greater than 1 cm. The quality of calcar reduction nearly reached statistical significance, and 44.8% of patients who had inadequate reduction had lateralization of greater than 1 cm compared with 26.4% of patients who had adequate reduction (P=.054). Lateralization of greater than 1 cm was directly associated with the presence of symptoms (Ptrochanteric pain (P=.007). Multivariate analysis showed that increasing tip-apex distance, inadequate calcar reduction, and greater fracture severity were predictive of excessive lateralization of greater than 1 cm. Nearly 20% of patients had lateral hip pain associated with cephalomedullary fixation. Final lateralization of the helical blade of greater than 1 cm was a very strong predictor of symptoms. During preoperative counseling, surgeons should caution patients about this relatively frequent and likely underreported complication. [Orthopedics. 2017; 40(5):e886-e891.]. Copyright 2017, SLACK Incorporated.

  19. Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures.

    Science.gov (United States)

    Wang, Cheng; Li, Ying; Huang, Lei; Wang, Manyi

    2010-10-01

    To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I and II. Two-staged ORIF was performed in group I and LIFEF in group II. The outcome measures included bone union, nonunion, malunion, pin-tract infection, wound infection, osteomyelitis, ankle joint function, etc. These postoperative data were analyzed with Statistical Package for Social Sciences (SPSS) 13.0. Incidence of superficial soft tissue infection (involved in wound infection or pin-tract infection) in group I was lower than that in group II (P delayed union, and arthritis symptoms, with no statistical significance. Both groups resulted similar ankle joint function. Logistic regression analysis indicated that smoking and fracture pattern were the two factors significantly influencing the final outcomes. In the treatment of closed tibial plafond fractures, both two-staged ORIF and LIFEF offer similar results. Patients undergo LIFEF carry significantly greater radiation exposure and higher superficial soft tissue infection rate (usually occurs on pin tract and does not affect the final outcomes).

  20. Contraceptive failure

    DEFF Research Database (Denmark)

    Rasch, Vibeke

    2002-01-01

    Most studies focusing on contraceptive failure in relation to pregnancy have focused on contraceptive failure among women having induced abortions, thereby neglecting those women who, despite contraceptive failure, accept the pregnancy and intend to carry the fetus to term. To get a more complete...... picture of the problem of contraceptive failure, this study focuses on contraceptive failure among women with diverse pregnancy outcomes. In all, 3520 pregnant women attending Odense University Hospital were included: 373 had induced abortions, 435 had spontaneous abortions, 97 had ectopic pregnancies......, and 2614 received antenatal care. The variables studied comprise age, partner relationship, number of births, occupational and economical situation, and contraceptive use.Contraceptive failure, defined as contraceptive use (condom, diaphragm, IUD, oral contraception, or another modern method...

  1. Mechanical evaluation of external skeletal fixator-intramedullary pin tie-in configurations applied to cadaveral humeri from red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Van Wettere, Arnaud J; Redig, Patrick T; Wallace, Larry J; Bourgeault, Craig A; Bechtold, Joan E

    2009-12-01

    Use of external skeletal fixator-intramedullary pin (ESF-IM) tie-in fixators is an adjustable and effective method of fracture fixation in birds. The objective of this study was to determine the contribution of each of the following parameters to the compressive and torsional rigidity of an ESF-IM pin tie-in applied to avian bones with an osteotomy gap: (1) varying the fixation pin position in the proximal bone segment and (2) increasing the number of fixation pins in one or both bone segments. ESF-IM pin tie-in constructs were applied to humeri harvested from red-tailed hawks (Buteo jamaicensis) (n=24) that had been euthanatized for clinical reasons. Constructs with a variation in the placement of the proximal fixation pin and with 2, 3, or 4 fixation pins applied to avian bone with an osteotomy gap were loaded to a defined displacement in torque and axial compression. Response variables were determined from resulting load-displacement curves (construct stiffness, load at 1-mm displacement). Increasing the number of fixation pins from 1 to 2 per bone segment significantly increased the stiffness in torque (110%) and compression (60%), and the safe load in torque (107%) and compression (50%). Adding a fixation pin to the distal bone segment to form a 3-pin fixator significantly increased the stiffness (27%) and safe load (20%) in torque but not in axial compression. In the configuration with 2 fixation pins, placing the proximal pin distally in the proximal bone segment significantly increased the stiffness in torque (28%), and the safe load in torque (23%) and in axial compression (32%). Results quantified the relative importance of specific parameters affecting the rigidity of ESF-IM pin tie-in constructs as applied to unstable bone fracture models in birds.

  2. Nonunited humerus shaft fractures treated by external fixator augmented by intramedullary rod

    Directory of Open Access Journals (Sweden)

    Mahmoud A El-Rosasy

    2012-01-01

    Full Text Available Background: Nonunion of humeral shaft fractures after previously failed surgical treatment presents a challenging therapeutic problem especially in the presence of osteoporosis, bone defect, and joint stiffness. It would be beneficial to combine the use of external fixation technique and intramedullary rod in the treatment of such cases. The present study evaluates the results of using external fixator augmented by intramedullary rod and autogenous iliac crest bone grafting (ICBG for the treatment of humerus shaft nonunion following previously failed surgical treatment. Materials and Methods: Eighteen patients with atrophic nonunion of the humeral shaft following previous implant surgery with no active infection were included in the present study. The procedure included exploration of the nonunion, insertion of intramedullary rod (IM rod, autogenous ICBG and application of external fixator for compression. Ilizarov fixator was used in eight cases and monolateral fixator in ten cases. The monolateral fixator was preferred for females and obese patients to avoid abutment against the breast or chest wall following the use of Ilizarov fixator. The fixator was removed after clinical and radiological healing of the nonunion, but the IM rod was left indefinitely. The evaluation of results included both bone results (union rate, angular deformity and limb shortening and functional outcome using the University of California, Los Angeles (UCLA rating scale. Results: The mean follow-up was 35 months (range 24 to 52 months. Bone union was obtained in all cases. The functional outcome was satisfactory in 15 cases (83% and unsatisfactory in 3 cases (17% due to joint stiffness. The time to bone healing averaged 4.2 months (range 3 to 7 months. The external fixator time averaged 4.5 months (range 3.2 to 8 months. Superficial pin tract infection occurred in 39% (28/72 of the pins. No cases of nerve palsy, refracture, or deep infection were encountered

  3. Plant densities and modulation of symbiotic nitrogen fixation in soybean

    Directory of Open Access Journals (Sweden)

    Marcos Javier de Luca

    2014-06-01

    Full Text Available Soybean nitrogen (N demands can be supplied to a large extent via biological nitrogen fixation, but the mechanisms of source/sink regulating photosynthesis/nitrogen fixation in high yielding cultivars and current crop management arrangements need to be investigated. We investigated the modulation of symbiotic nitrogen fixation in soybean [Glycine max (L. Merrill] at different plant densities. A field trial was performed in southern Brazil with six treatments, including non-inoculated controls without and with N-fertilizer, both at a density of 320,000 plants ha−1, and plants inoculated with Bradyrhizobium elkanii at four densities, ranging from 40,000 to 320,000 plants ha−1. Differences in nodulation, biomass production, N accumulation and partition were observed at stage R5, but not at stage V4, indicating that quantitative and qualitative factors (such as sunlight infrared/red ratio assume increasing importance during the later stages of plant growth. Decreases in density in the inoculated treatments stimulated photosynthesis and nitrogen fixation per plant. Similar yields were obtained at the different plant densities, with decreases only at the very low density level of 40,000 plants ha−1, which was also the only treatment to show differences in seed protein and oil contents. Results confirm a fine tuning of the mechanisms of source/sink, photosynthesis/nitrogen fixation under lower plant densities. Higher photosynthesis and nitrogen fixation rates are capable of sustaining increased plant growth.

  4. Porcine intestinal mast cells. Evaluation of different fixatives for histochemical staining techniques considering tissue shrinkage

    Directory of Open Access Journals (Sweden)

    J. Rieger

    2013-07-01

    Full Text Available Staining of mast cells (MCs, including porcine ones, is critically dependent upon the fixation and staining technique. In the pig, mucosal and submucosal MCs do not stain or stain only faintly after formalin fixation. Some fixation methods are particularly recommended for MC staining, for example the fixation with Carnoy or lead salts. Zinc salt fixation (ZSF has been reported to work excellently for the preservation of fixation-sensitive antigens. The aim of this study was to establish a reliable histological method for counting of MCs in the porcine intestinum. For this purpose, different tissue fixation and staining methods that also allow potential subsequent immunohistochemical investigations were evaluated in the porcine mucosa, as well as submucosa of small and large intestine. Tissues were fixed in Carnoy, lead acetate, lead nitrate, Zamboni and ZSF and stained subsequently with either polychromatic methylene blue, alcian blue or toluidine blue. For the first time our study reveals that ZSF, a heavy metal fixative, preserves metachromatic staining of porcine MCs. Zamboni fixation was not suitable for histochemical visualization of MCs in the pig intestine. All other tested fixatives were suitable. Alcian blue and toluidine blue co-stained intestinal goblet cells which made a prima facie identification of MCs difficult. The polychromatic methylene blue proved to be the optimal staining. In order to compare MC counting results of the different fixation methods, tissue shrinkage was taken into account. As even the same fixation caused shrinkage-differences between tissue from small and large intestine, different factors for each single fixation and intestinal localization had to be calculated. Tissue shrinkage varied between 19% and 57%, the highest tissue shrinkage was found after fixation with ZSF in the large intestine, the lowest one in the small intestine after lead acetate fixation. Our study emphasizes that MC counting results from

  5. Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The 'fix and shift' technique.

    Science.gov (United States)

    Ramasamy, P R

    2017-01-01

    Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

  6. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  7. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    Science.gov (United States)

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  8. Spinopelvic Dissociation: Comparison of Outcomes of Percutaneous versus Open Fixation Strategies

    Directory of Open Access Journals (Sweden)

    Jeffrey M. Pearson

    2018-01-01

    Full Text Available Introduction. Spinopelvic dissociation injuries are historically treated with open reduction with or without decompressive laminectomy. Recent technological advances have allowed for percutaneous fixation with indirect reduction. Herein, we evaluate outcomes and complications between patients treated with open reduction versus percutaneous spinopelvic fixation. Methods. Retrospective review of patients undergoing spinopelvic fixation from a single, level one trauma center from 2012 to 2017. Patient information regarding demographics, associated injuries, and treatment outcome measures was recorded and analyzed. All fractures were classified via the AO Spine classification system. Results. Thirty-one spinopelvic dissociations were identified: 15 treated with open and 16 with percutaneous techniques. The two treatment groups had similar preoperative characteristics including spinopelvic parameters (pelvic incidence and lumbar lordosis. Compared to open reduction internal fixation, percutaneous fixation of spinopelvic dissociation resulted in statistically significantly lower blood loss (171 cc versus 538 cc; p=0.0013. There were no significant differences in surgical site infections (p=0.48 or operating room time (p=0.66. Conclusion. Percutaneous fixation of spinopelvic dissociation is associated with significantly less blood loss. Treatment outcomes in terms of infection, length of stay, operative cost, and final alignment between the open and percutaneous group were similar.

  9. Hybrid fixation in the bilateral sagittal split osteotomy for lower jaw advancement

    Directory of Open Access Journals (Sweden)

    Felipe Ladeira Pereira

    2010-02-01

    Full Text Available Miniplate and screw fixation has been widely used in bilateral sagittal split osteotomy, but some issues remain unclear concerning its lack of rigidity when compared to Spiessl's bicortical technique. This paper demonstrates the hybrid fixation technique in a case report. A 34-year-old female patient underwent a double jaw surgery with counter-clockwise rotation of the mandible fixed using the hybrid fixation technique. The patient evolved well in the postoperative period and is still under follow up after 14 months, reporting satisfaction with the results and no significant deviation from the treatment plan up to now. No damage to tooth roots was done, maxillomandibular range of motion was within normality and regression of the inferior alveolar nerve paresthesia was observed bilaterally. The hybrid mandibular fixation is clearly visible in the panoramic and cephalometric control radiographs. It seems that the hybrid fixation can sum the advantages of both monocortical and bicortical techniques in lower jaw advancement, increasing fixation stability without significant damage to the mandibular articulation and the inferior alveolar nerve. A statistical investigation seems necessary to prove its efficacy.

  10. Fixation of strategies with the Moran and Fermi processes in evolutionary games

    Science.gov (United States)

    Liu, Xuesong; He, Mingfeng; Kang, Yibin; Pan, Qiuhui

    2017-10-01

    A model of stochastic evolutionary game dynamics with finite population was built. It combines the standard Moran and Fermi rules with two strategies cooperation and defection. We obtain the expressions of fixation probabilities and fixation times. The one-third rule which has been found in the frequency dependent Moran process also holds for our model. We obtain the conditions of strategy being an evolutionarily stable strategy in our model, and then make a comparison with the standard Moran process. Besides, the analytical results show that compared with the standard Moran process, fixation occurs with higher probabilities under a prisoner's dilemma game and coordination game, but with lower probabilities under a coexistence game. The simulation result shows that the fixation time in our mixed process is lower than that in the standard Fermi process. In comparison with the standard Moran process, fixation always takes more time on average in spatial populations, regardless of the game. In addition, the fixation time decreases with the growth of the number of neighbors.

  11. Genetic variants of age at menopause are not related to timing of ovarian failure in breast cancer survivors.

    Science.gov (United States)

    Homer, Michael V; Charo, Lindsey M; Natarajan, Loki; Haunschild, Carolyn; Chung, Karine; Mao, Jun J; DeMichele, Angela M; Su, H Irene

    2017-06-01

    To determine if interindividual genetic variation in single-nucleotide polymorphisms (SNPs) related to age at natural menopause is associated with risk of ovarian failure in breast cancer survivors. A prospective cohort of 169 premenopausal breast cancer survivors recruited at diagnosis with stages 0 to III disease were followed longitudinally for menstrual pattern via self-reported daily menstrual diaries. Participants were genotyped for 13 SNPs previously found to be associated with age at natural menopause: EXO1, TLK1, HELQ, UIMC1, PRIM1, POLG, TMEM224, BRSK1, and MCM8. A risk variable summed the total number of risk alleles in each participant. The association between individual genotypes, and also the risk variable, and time to ovarian failure (>12 months of amenorrhea) was tested using time-to-event methods. Median age at enrollment was 40.5 years (range 20.6-46.1). The majority of participants were white (69%) and underwent chemotherapy (76%). Thirty-eight participants (22%) experienced ovarian failure. None of the candidate SNPs or the summary risk variable was significantly associated with time to ovarian failure. Sensitivity analysis restricted to whites or only to participants receiving chemotherapy yielded similar findings. Older age, chemotherapy exposure, and lower body mass index were related to shorter time to ovarian failure. Thirteen previously identified genetic variants associated with time to natural menopause were not related to timing of ovarian failure in breast cancer survivors.

  12. [Case-control study on measurement of coracoclavicular and acromioclavicular ligament injuries during internal fixation operation for the treatment of fresh acromioclavicular joint dislocation of Tossy type III].

    Science.gov (United States)

    Guan, Ting-Jin; Sun, Peng; Zheng, Liang-Guo; Qi, Xiang-Yang

    2014-01-01

    To study measurement methods of acromioclavicular and coracoclavicular ligament injuries,its therapeutic effects and complications during internal fixation operation for the treatment of fresh acromioclavicular joint dislocations of Tossy type III. From July 2003 to May 2012,127 patients with acromioclavicular joint dislocations of Tossy type III were treated with wire fixation from coracoid process to clavicle or hook-plate fixation. The patients were divided into group A (63 cases) and group B (64 cases) according to whether acromioclavicular ligament and coracoclavicular ligament were repaired or not. In group A (ligaments repaired), there were 39 males and 24 females with an average age of (33.25 +/- 8.46) years old (ranged from 17 to 59 years). And in group B (no ligaments repaired), there were 41 males and 23 females with an average age of (34.10 +/- 7.19) years (ranged from 19 to 57 years). The operation times, intraoperative blood loss, postoperative infections, internal fixation failure, recurrence and other complications, together with therapeutic effects were compared between two groups. The outcome was analyzed according to Karlsson standard. In group A, 54 patients got an excellent result and 9 good according to Karlsson standard;the average operative time was (55.90 +/- 26.56) min; the average intraoperative bleeding amount was (99.80 +/- 50.30) ml; 1 patient had wire broken without re-dislocation at 16 weeks after operation, 3 patients got wound fat liquefaction and recovered after treatment, 1 patient had pain after shoulder joint motion and pain disappeared after implants were taken out. In group B, 52 patients got an excellent result and 12 good according to Karlsson standard; the average operative time was (49.50 +/- 23.14) min; the average intraoperative bleeding amount was (87.30 +/- 46.41) ml; 2 patients got wound fat liquefaction, and 2 patients had pain after shoulder joint motion. All the patients were followed up, and the duration ranged

  13. Cephalomedullary fixation for femoral neck/intertrochanteric and ipsilateral shaft fractures: surgical tips and pitfalls

    Directory of Open Access Journals (Sweden)

    Bali Kamal

    2013-02-01

    Full Text Available 【Abstract】Objective: Surgical management op-tions for femoral shaft fracture and ipsilateral proximal fe-mur fracture vary from single-implant to double-implant fixation. Cephalomedullary fixation in such fractures has rela-tive advantages over other techniques especially because of less soft tissue dissection and immediate postoperative weight bearing with accelerated rehabilitation. However, the surgery is technically demanding and there is a paucity of literature describing the surgical techniques for this fixation. The aim of the study was to describe the surgical technique of cephalomedullary fixation for femoral shaft fracture and ipsilateral proximal femur fracture. Methods: Sixteen cases (10 males and 6 females with a mean age of 41.8 years of ipsilateral proximal femur and shaft fractures were treated by single-stage cephalomedullary fixa-tion at tertiary level trauma center in northern India. The fractures were classified according to AO classification. An intraoperative record of duration of surgery as well as tech-nical challenges unique to each fracture pattern was kept for all the patients. Results: The most common proximal femoral pattern was AO B2.1 observed in 9 of our patients. The AO B2.3 fractures were seen in 4 patients while the AO A1.2 fractures in 3 patients. Four of the AO B2.1 and 2 of the AO B2.3 frac-tures required open reduction with Watson-Jones approach. The mean operative time was around 78 minutes, which tended to decrease as the surgical experience increased. There was only one case of malreduction, which required revision surgery. Conclusion: Combination of ipsilateral femoral shaft fracture and neck/intertrochanteric fracture is a difficult frac-ture pattern for trauma surgeons. Cephalomedullary nail is an excellent implant for such fractures but it requires careful insertion to avoid complications. Surgery is technically de-manding with a definite learning curve. Nevertheless, a ma-jority of these

  14. On experiments to detect possible failures of relativity theory

    International Nuclear Information System (INIS)

    Rodrigues Junior, W.A.; Tiomno, J.

    1985-01-01

    Two recently proposed experiments by Kolen and Torr, designed to show failures of Einstein's Special Relativity (SR) are analysed. It is pointed out that these papers contain a number of imprecisions and misconceptions which are cleared out. Also the very spread misconception about anysotropy of propagation of light in vacuum in Lorentz Aether Theory (LAT) is analysed showing that the anysotropy is only a coordinate effect. Comparison of the correct results in LAT theory, leading to violation of SR, with new theoretical and experimental results of Torr et al is made. Some of these new results are shown to be incorrect and/or inconsistent with both SR and LAT. (Author) [pt

  15. Comparison of /sup 15/N-aided methods for determining symbiotic dinitrogen fixation

    Energy Technology Data Exchange (ETDEWEB)

    Rennie, R J [International Atomic Energy Agency, Vienna (Austria). Joint FAO/IAEA Div. of Atomic Energy in Food and Agriculture

    1979-01-01

    Three methods of calculating the amount of symbiotic dinitrogen fixation in navy beans (Phaseolus vulgaris cv. Sanilac) were compared in a greenhouse experiment. /sup 15/N-isotope dilution procedures yielded the most logical estimation of dinitrogen fixation. The classical difference method was not in agreement. Potential errors of the 'A'-value procedure to calculate dinitrogen fixation are discussed.

  16. Positive Affect Is Associated With Reduced Fixation in a Realistic Medical Simulation.

    Science.gov (United States)

    Crane, Monique F; Brouwers, Sue; Forrest, Kirsty; Tan, Suyin; Loveday, Thomas; Wiggins, Mark W; Munday, Chris; David, Leila

    2017-08-01

    This study extends previous research by exploring the association between mood states (i.e., positive and negative affect) and fixation in practicing anesthetists using a realistic medical simulation. The impact of practitioner emotional states on fixation is a neglected area of research. Emerging evidence is demonstrating the role of positive affect in facilitating problem solving and innovation, with demonstrated implications for practitioner fixation. Twelve practicing anesthetists (4 females; M age = 39 years; SD = 6.71) were involved in a medical simulation. Prior to the simulation, practitioners rated the frequency they had experienced various positive and negative emotions in the previous three days. During the simulation, the patient deteriorated rapidly, and anesthetists were observed for their degree of fixation. After the simulation, practitioners indicated the frequency of these same emotions during the simulation. Nonparametric correlations were used to explore the independent relationships between positive and negative affect and the behavioral measures. Only positive affect impacted the likelihood of fixation. Anesthetists who reported more frequent recent positive affect in the three days prior to the simulation and during the simulation tended to be less fixated as judged by independent raters, identified a decline in patient oxygen saturation more quickly, and more rapidly implemented the necessary intervention (surgical cricothyroidotomy). These findings have some real-world implications for positive affect in patient safety. This research has broad implications for professions where fixation may impair practice. This research suggests that professional training should teach practitioners to identify their emotions and understand the role of these emotions in fixation.

  17. Biome-scale nitrogen fixation strategies selected by climatic constraints on nitrogen cycle.

    Science.gov (United States)

    Sheffer, Efrat; Batterman, Sarah A; Levin, Simon A; Hedin, Lars O

    2015-11-23

    Dinitrogen fixation by plants (in symbiosis with root bacteria) is a major source of new nitrogen for land ecosystems(1). A long-standing puzzle(2) is that trees capable of nitrogen fixation are abundant in nitrogen-rich tropical forests, but absent or restricted to early successional stages in nitrogen-poor extra-tropical forests. This biome-scale pattern presents an evolutionary paradox(3), given that the physiological cost(4) of nitrogen fixation predicts the opposite pattern: fixers should be out-competed by non-fixers in nitrogen-rich conditions, but competitively superior in nitrogen-poor soils. Here we evaluate whether this paradox can be explained by the existence of different fixation strategies in tropical versus extra-tropical trees: facultative fixers (capable of downregulating fixation(5,6) by sanctioning mutualistic bacteria(7)) are common in the tropics, whereas obligate fixers (less able to downregulate fixation) dominate at higher latitudes. Using a game-theoretic approach, we assess the ecological and evolutionary conditions under which these fixation strategies emerge, and examine their dependence on climate-driven differences in the nitrogen cycle. We show that in the tropics, transient soil nitrogen deficits following disturbance and rapid tree growth favour a facultative strategy and the coexistence of fixers and non-fixers. In contrast, sustained nitrogen deficits following disturbance in extra-tropical forests favour an obligate fixation strategy, and cause fixers to be excluded in late successional stages. We conclude that biome-scale differences in the abundance of nitrogen fixers can be explained by the interaction between individual plant strategies and climatic constraints on the nitrogen cycle over evolutionary time.

  18. [Usefullness of intrasacral fixation in an extremely unstable lumbosacral spine].

    Science.gov (United States)

    Nishiura, Tsukasa; Nishiguchi, Mitsuhisa; Kusaka, Noboru; Takayama, Kazuhiro; Maeda, Yasuhiko; Ogihara, Kotaro; Nakagawa, Minoru

    2007-04-01

    Intrasacral fixation technique devised by Jackson is said to provide rigid lumbosacral fixation. We treated 3 cases of lumbosacral lesions using this technique in which lumbosacral segment had become extremely unstable during surgical intervention adding to the effect of original lesions. In all cases, surgeries were performed in 2 stages, intrasacral fixation and anterior stabilization. Case 1: A 52-year-old male was diagnosed fungal discitis and spondylitis at L4 and L5. X-ray showed destruction of the vertebral bodies. L2, L3 and sacrum were fixed posteriorly using the intrasacral fixation technique. One week after the first operation, L4 and L5 vertebral bodies were replaced by long fibula grafts through the extraperitoneal approach. Case 2: A 25-year-old female with cauda equina syndrome and abnormal body form diagnosed as having spondyloptosis in which the entire vertebral body of L5 had descended below the endplate of S1. MR imaging revealed marked canal stenosis at the S1 level. In the first surgery, L5 vertebral body was resected through the transperitoneal approach. After 1 week of bed rest, posterior segments of L5 were resected, L4 was affixed to the sacrum and anterior stabilization was achieved with 2 mesh cages and lumbosacral spine was fixed using the intrasacral fixation technique. Case 3: A 64-year-old female was diagnosed as having pyogenic discitis and osteomyelitis at the L5-S1 level. In spite of successful medical treatment for infection, low back pain continued. Radiologically, L5 vertebral body was shown to have collapsed and slipped anteriorly over the sacrum. L3, L4 and sacrum were fixed by intrasacral fixation. One week after the first operation, the L5/S1 disc and the suppurtive vertebral bodies were resected through the extraperitoneal approach and anterior stabilization was performed with iliac bone grafts. At follow-up for a minimum of 6 months, initial fixation was maintained in all 3 cases and bony fusion was obtained. The

  19. Postinflammatory ossicular fixation: CT analysis with surgical correlation

    International Nuclear Information System (INIS)

    Swartz, J.D.; Wolfson, R.J.; Marlowe, F.I.; Popky, G.L.

    1985-01-01

    Postinflammatory ossicular fixation is a common problem encountered by the otologic surgeon upon exploration because of conductive hearing loss in patients with chronic otitis media. These nonotosclerotic noncongenital lesions take three pathologic forms: fibrous tissue fixation (chronic adhesive otitis media), hyalinization of collagen (tympanosclerosis), and new bone formation (fibro-osseous sclerosis). More than 300 patients with the clinical diagnosis of chronic otitis media have been examined. This study encompasses 23 proved cases

  20. CARBON DIOXIDE FIXATION.

    Energy Technology Data Exchange (ETDEWEB)

    FUJITA,E.

    2000-01-12

    Solar carbon dioxide fixation offers the possibility of a renewable source of chemicals and fuels in the future. Its realization rests on future advances in the efficiency of solar energy collection and development of suitable catalysts for CO{sub 2} conversion. Recent achievements in the efficiency of solar energy conversion and in catalysis suggest that this approach holds a great deal of promise for contributing to future needs for fuels and chemicals.

  1. End-stage hindfoot arthrosis: outcomes of tibiocalcaneal fusion using internal and Ilizarov fixation.

    Science.gov (United States)

    Crawford, Brooke; Watson, J Tracy; Jackman, James; Fissel, Brian; Karges, David E

    2014-01-01

    End-stage post-traumatic pantalar arthrosis from ankle, pilon, and talus fractures has often been complicated by infection, bone loss, and a soft tissue deficit. Patients can present with neuropathy, diabetes, tobacco use, and previously failed arthrodesis. Fusion in this population has been challenging, with nonunion rates up to 30%, often leading to amputation. We reviewed the results of a standardized protocol that combined simultaneous internal fixation with the Ilizarov technique to achieve fusion in high-risk patients. With institutional review board approval, a retrospective review of the patients treated with simultaneous internal fixation and an Ilizarov frame was undertaken. The records and radiographs allowed identification of the comorbidities and the presence or absence of successful fusion. Complications were acknowledged and treated. Fifteen patients had undergone the procedure. The mean follow-up period was 27.9 (range 9 to 67) months. Thirteen patients (86.67%) had had previous fusion failure. Twelve patients (80%) had developed post-traumatic arthrosis, 5 (33.33%) of whom had open injuries. All patients had 1 comorbidity, and 10 (66.67%) had multiple, including rheumatoid arthritis, diabetes (types 1 and 2), and smoking. Four patients (26.67%) presented with deep infection and bone loss. Union was achieved in 11 (73.33%), with 12 (80%) patients experiencing profound pain relief. Seven patients (46.67%) required symptomatic hardware removal. Three patients (20%) eventually underwent below-the-knee amputation for recalcitrant nonunion. Statistically significant correlations were found between smoking and wound infection and revision and between nonunion and amputation. Our results have indicated that combined internal fixation with Ilizarov application can provide a strong surgical option for the management of end-stage, pantalar arthritis. More studies are needed to compare the cohort outcomes and gait analysis in these patients with those who have

  2. Fixation and partitioning of heavy metals in slag after incineration of sewage sludge.

    Science.gov (United States)

    Chen, Tao; Yan, Bo

    2012-05-01

    Fixation of heavy metals in the slag produced during incineration of sewage sludge will reduce emission of the metals to the atmosphere and make the incineration process more environmentally friendly. The effects of incineration conditions (incineration temperature 500-1100°C, furnace residence time 0-60min, mass fraction of water in the sludge 0-75%) on the fixation rates and species partitioning of Cd, Pb, Cr, Cu, Zn, Mn and Ni in slag were investigated. When the incineration temperature was increased from 500 to 1100°C, the fixation rate of Cd decreased from 87% to 49%, while the fixation rates of Cu and Mn were stable. The maximum fixation rates for Pb and Zn and for Ni and Cr were reached at 900 and 1100°C, respectively. The fixation rates of Cu, Ni, Cd, Cr and Zn decreased as the residence time increased. With a 20min residence time, the fixation rates of Pb and Mn were low. The maximum fixation rates of Ni, Mn, Zn, Cu and Cr were achieved when the mass fraction of water in the sludge was 55%. The fixation rate of Cd decreased as the water mass fraction increased, while the fixation rate of Pb increased. Partitioning analysis of the metals contained in the slag showed that increasing the incineration temperature and residence time promoted complete oxidation of the metals. This reduced the non-residual fractions of the metals, which would lower the bioavailability of the metals. The mass fraction of water in the sludge had little effect on the partitioning of the metals. Correlation analysis indicated that the fixation rates of heavy metals in the sludge and the forms of heavy metals in the incinerator slag could be controlled by optimization of the incineration conditions. These results show how the bioavailability of the metals can be reduced for environmentally friendly disposal of the incinerator slag. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Emergency department external fixation for provisional treatment of pilon and unstable ankle fractures

    Directory of Open Access Journals (Sweden)

    Craig R Lareau

    2015-01-01

    Full Text Available Unstable ankle fractures and impacted tibial pilon fractures often benefit from provisional external fixation as a temporizing measure prior to definitive fixation. Benefits of external fixation include improved articular alignment, decreased articular impaction, and soft tissue rest. Uniplanar external fixator placement in the Emergency Department (ED ex-fix is a reliable and safe technique for achieving ankle reduction and stability while awaiting definitive fixation. This procedure involves placing transverse proximal tibial and calcaneal traction pins and connecting the pins with two external fixator rods. This technique is particularly useful in austere environments or when the operating room is not immediately available. Additionally, this bedside intervention prevents the patient from requiring general anesthesia and may be a cost-effective strategy for decreasing valuable operating time. The ED ex-fix is an especially valuable procedure in busy trauma centers and during mass casualty events, in which resources may be limited.

  4. Factors associated with health-related quality of life in stable ambulatory congestive heart failure patients: Systematic review.

    Science.gov (United States)

    Baert, Anneleen; De Smedt, Delphine; De Sutter, Johan; De Bacquer, Dirk; Puddu, Paolo Emilio; Clays, Els; Pardaens, Sofie

    2018-03-01

    Background Since improved treatment of congestive heart failure has resulted in decreased mortality and hospitalisation rates, increasing self-perceived health-related quality of life (HRQoL) has become a major goal of congestive heart failure treatment. However, an overview on predictieve factors of HRQoL is currently lacking in literature. Purpose The aim of this study was to identify key factors associated with HRQoL in stable ambulatory patients with congestive heart failure. Methods A systematic review was performed. MEDLINE, Web of Science and Embase were searched for the following combination of terms: heart failure, quality of life, health perception or functional status between the period 2000 and February 2017. Literature screening was done by two independent reviewers. Results Thirty-five studies out of 8374 titles were included for quality appraisal, of which 29 were selected for further data extraction. Four distinct categories grouping different types of variables were identified: socio-demographic characteristics, clinical characteristics, health and health behaviour, and care provider characteristics. Within the above-mentioned categories the presence of depressive symptoms was most consistently related to a worse HRQoL, followed by a higher New York Heart Association functional class, younger age and female gender. Conclusion Through a systematic literature search, factors associated with HRQoL among congestive heart failure patients were investigated. Age, gender, New York Heart Association functional class and depressive symptoms are the most consistent variables explaining the variance in HRQoL in patients with congestive heart failure. These findings are partly in line with previous research on predictors for hard endpoints in patients with congestive heart failure.

  5. Trochanteric Fixation With a Third-Generation Cable-Plate System: An Independent Experience.

    Science.gov (United States)

    Stewart, Andrew D; Abdelbary, Hesham; Beaulé, Paul E

    2017-09-01

    Greater trochanteric fracture/nonunion can be a devastating complication with significant functional impact after total hip arthroplasty, and their fixation remains a challenge because of the significant forces being transmitted as well as the poor bone quality often associated with these fractures. The objective of this study is to investigate the rates of reoperation and trochanteric nonunion using a third-generation cable-plate system at one center. Thirty-five patients, mean age 72.9 years (range 46-98 years) with 24 women and 11 men, underwent fixation of their fractured greater trochanter using a third-generation cable-plate system. The indications were: periprosthetic fracture (n = 17), complex primary arthroplasty (n = 5), and complex revision arthroplasty (n = 13). Primary outcomes included rates of reoperation and radiographic union. At a mean follow-up of 2.5 years, trochanteric union rate was 62.9% with nonunion rate of 31.4%, and fibrous union in 5.7%. In regard to quality of initial apposition, only 40% achieved a perfect bone on bone reduction. Ten patients (28.6%) had evidence of wire breakage. Five patients (14.3%) required reoperation and removal of the internal fixation because of lateral hip pain. Fixation of the trochanteric fractures remains a challenge with a relatively high reoperation rate. Poor bone quality and capacity to maintain a stable reduction continue to make this complication after total hip arthroplasty a difficult problem to solve. Copyright © 2017. Published by Elsevier Inc.

  6. [Domestic external fixator application in the treatment of limb deformities: 7 289 cases application report].

    Science.gov (United States)

    Qin, S H; Guo, B F; Zheng, X J; Jiao, S F; Xia, H T; Peng, A M; Pan, Q; Zang, J C; Wang, Z J

    2017-09-01

    Objective: To discuss the clinical application and effects of domestic external fixator in the treatment of patients with malformations of limbs. Methods: A total of 7 289 patients with malformation of limbs who had been operated in Qin Sihe orthopedic surgery team from January 1989 to June 2016 were retrospective analyzed. The patients were treated with domestic external fixator, including 4 033 males and 3 256 females, aging from 2 to 82 years with a mean age of 23.4 years. There were 2 732 patients using Ilizarov external fixator, 4 713 patients using hybrid external fixator, 57 patients using monobrachial external fixator, 232 patients using Ilizarov external fixator and hybrid external fixator. The Ilizarov, hybrid and monobrachial external fixator were used in 67, 65 and 0 patients on the upper limbs and in 2 665, 4 616 and 57 patients on the lower limbs. There were 3 028 patients operated on the left limbs, 3 260 patients operated on the right limbs and 1 001 patients operated on the bilateral limbs. The top three types of diseases were sequelae of poliomyelitis, cerebral palsy and post-traumatic stress disorder peromely. Deformity types inclued talipes equinovarus, knee flexion deformity, cavus foot and so on. Results: All the patients were followed up for a period of 2.5 months to 22.4 years, with an average follow-up time of 5.4 years. All of the external fixators were used for single once, and there was no substitute for external fixator quality problem. All the patients were completed surgery goal until removing external fixation except 1 patient gave up treatment and 1 removed the fixator because of metal allergy. The common complications included wire or pin infection and joint movement limitation and so on. Conclusions: The domestic external fixator developed and produced based on the characteristics of Chinese limb deformity disability. The domestic external fixator can be used to treat kinds of limb deformities with the advantages of practical

  7. Hydrologic Control on Bacterial Nitrogen Fixation in the Holocene Black Sea

    Science.gov (United States)

    Fulton, J. M.; Arthur, M. A.; Freeman, K. H.

    2008-12-01

    Stratified oceans of the Phanerozoic Oceanic Anoxic Events apparently were dominated by bacterial nitrogen fixation. Decreased marine N:P nutrient ratios resulting from increased denitrification and decreased phosphate burial efficiency under anoxic waters drove this nutrient regime. This model is upheld by the presence of cyanobacterial hopanoid biomarkers in sedimentary records and δ15N values indicative of nitrogen fixation. However, in the largest modern redox-stratified marine basin, the Black Sea, bacterial nitrogen fixation seems to be only a minor contributor to the nitrogen cycle. In this study, we use geochemical proxies to evaluate the role of bacterial nitrogen fixation during the deposition of the Holocene Black Sea sapropel, starting 7.8 ka. We report compound-specific nitrogen and carbon stable isotope values of pyropheophytin a, a chlorophyll degradation product, and bacteriochlorophyll e produced by green sulfur bacteria. We also present the surprising finding of scytonemin, a pigment produced only by filamentous cyanobacteria exposed to ultraviolet radiation, in certain intervals in these sediments. In the Holocene, nitrogen fixation in the Black Sea is most prominent during times of reduced river water influx. This directly decreases the external flux of nitrate into the surface waters. Reduced freshwater influx also decreases the volume of low salinity water dispersed around the sea by the Rim Current, allowing the chemocline to shoal along the margins. Previous geochemical studies have described this changing chemocline geometry. The exposure of shallow water sediments to anoxic waters further stimulates nitrogen fixation by releasing more phosphorus to the system. Nitrogen fixation is recorded in the sediments as bulk and compound-specific pyropheophytin a δ15N values near 0 ‰ and -5 ‰, respectively. We have also detected scytonemin in two intervals characterized by especially low δ15N values. This compound suggests abundant filamentous

  8. Nitrogen fixation in Red Sea seagrass meadows

    KAUST Repository

    Abdallah, Malak

    2017-05-01

    Seagrasses are key coastal ecosystems, providing many ecosystem services. Seagrasses increase biodiversity as they provide habitat for a large set of organisms. In addition, their structure provides hiding places to avoid predation. Seagrasses can grow in shallow marine coastal areas, but several factors regulate their growth and distribution. Seagrasses can uptake different kinds of organic and inorganic nutrients through their leaves and roots. Nitrogen and phosphorous are the most important nutrients for seagrass growth. Biological nitrogen fixation is the conversion of atmospheric nitrogen into ammonia by diazotrophic bacteria. This process provides a significant source of nitrogen for seagrass growth. The nitrogen fixation is controlled by the nif genes which are found in diazotrophs. The main goal of the project is to measure nitrogen fixation rates on seagrass sediments, in order to compare among various seagrass species from the Red Sea. Moreover, we will compare the fixing rates of the Vegetated areas with the bare sediments. This project will help to ascertain the role of nitrogen fixing bacteria in the development of seagrass meadows.

  9. Dependence of carbon dioxide concentration on microalgal carbon dioxide fixation

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Yeoung Sang; Park, Song Moon [Department of Chemical Engineering, School of Environmental Engineering, Pohang University of Science and Technology, Pohang (Korea); Bolesky, Bohumil [Department of Chemical Engineering, McGill University (Canada)

    1999-10-01

    Batch cultivation of chlorella vulgaris was carried out under various CO{sub 2} concentrations in order to understand and describe mathematically the CO{sub 2} inhibition of microalgal CO{sub 2} fixation. The volumetric CO{sub 2} transfer coefficient from mixture gas to culture medium was estimated from the volumetric O{sub 2} transfer coefficient obtained experimentally. Using this transfer coefficient and aquatic equilibrium relationship between dissolved inorganic carbons, the behavior of dissolved CO{sub 2} was calculated during microalgal culture. When air containing 0.035%(v/v) CO{sub 2} was supplied into microalgal culture, the fixation rate was limited by CO{sub 2} transfer rate. However, the limitation was disappeared by supplying mixture gas containing above 2%(v/v) CO{sub 2} and the dissolved CO{sub 2} concentration was maintained at the saturated value. In the range of CO{sub 2} partial pressure in the flue gases from thermal power sations and steel-making plants, the microalgal CO{sub 2} fixation rate was inhibited. The CO{sub 2} fixation rate was successfully formulated by a new empirical equation as a function of dissolved CO{sub 2} concentration, which could be useful for modeling and simulating the performance of photobioreaction with enriched CO{sub 2}. Also, it was found that the CO{sub 2} inhibition of microalgal CO{sub 2} fixation was reversible and that microalgal CO{sub 2} fixation process could be stable against a shock of unusually high CO{sub 2} concentration. 29 refs., 8 figs.

  10. Drug-related acute renal failure in hospitalised patients.

    Science.gov (United States)

    Iavecchia, Lujan; Cereza García, Gloria; Sabaté Gallego, Mònica; Vidal Guitart, Xavier; Ramos Terrades, Natalia; de la Torre, Judith; Segarra Medrano, Alfons; Agustí Escasany, Antònia

    2015-01-01

    The information available on the incidence and the characteristics of patients with acute renal failure (ARF) related to drugs is scarce. To estimate the incidence of drug-related ARF in hospitalised patients and to compare their characteristics with those of patients with ARF due to other causes. We selected a prospective cohort of patients with ARF during hospital admission (July 2010-July 2011). Information on patients' demographics, medical antecedents, ARF risk factors, ARF severity according to the RIFLE classification and hospital drug administration was collected. We analysed the relationship of drugs with the ARF episodes using Spanish Pharmacovigilance System methods and algorithm. A total of 194 cases had an episode of hospital-acquired ARF. The median age of patients was 72 years [IQR 20]; 60% were men. The ARF incidence during hospitalization was 9.6 per 1,000 admissions. According to the RIFLE classification, a risk of kidney damage or kidney injury was present in 77.8% of cases. In 105 (54.1%) cases, ARF was drug-related; the drugs most frequently involved were diuretics, agents acting on the renin-angiotensin system, immunosuppressants, β-blocking agents, calcium channel blockers, contrast media and non-steroid anti-inflammatory drugs. Patients with drug-related ARF had more multi-morbidity, fewer ARF risk factors and lower mortality. Half of ARF episodes during hospitalisation were drug related. Patients with drug-related ARF had higher cardiovascular morbidity than those with ARF related to other causes, but they had a lower frequency of ARF risk factors and mortality. Copyright © 2015 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Evaluation of isotopic dilution method for measuring N2 fixation in azolla: comparison with other methods

    International Nuclear Information System (INIS)

    Sah, R.N.; Goyal, S.S.; Rains, D.W.; Paige, D.F.

    1989-01-01

    An isotopic dilution method that overcomes the drawbacks of commonly used methods for measuring N 2 fixation by aquatic N‐fixers such as Azolla pinnata‐Anabaena azollae association (Azolla) is presented. The method was compared with 15 N2 gas (while maintaining CO 2 ) and the difference methods of measuring N 2 fixation. The isotopic dilution method was used for two conditions: a. For 15 N‐free growth medium, Azolla was pre‐enriched with 15 N, and N 2 fixation was determined by measuring the dilution of 15 N in the tissue. b. For the growth medium containing N, N2 fixation was determined by providing 15 N enriched ammonium sulfate in the growth medium and measuring 15 N to 14 N ratio in the tissue. An airtight chamber, necessary for 15 N 2 gas and acetylene reduction methods, was not representative of the growing environment of Azolla. Temperature in the airtight chamber was far from uniform and CO 2 was rapidly depleted. The isotopic dilution method is simpler, relatively inexpensive, subject to fewer errors and applicable to more diverse conditions, and yet was as accurate as 15 N2‐gas method. (author)

  12. When the mean is not enough: Calculating fixation time distributions in birth-death processes.

    Science.gov (United States)

    Ashcroft, Peter; Traulsen, Arne; Galla, Tobias

    2015-10-01

    Studies of fixation dynamics in Markov processes predominantly focus on the mean time to absorption. This may be inadequate if the distribution is broad and skewed. We compute the distribution of fixation times in one-step birth-death processes with two absorbing states. These are expressed in terms of the spectrum of the process, and we provide different representations as forward-only processes in eigenspace. These allow efficient sampling of fixation time distributions. As an application we study evolutionary game dynamics, where invading mutants can reach fixation or go extinct. We also highlight the median fixation time as a possible analog of mixing times in systems with small mutation rates and no absorbing states, whereas the mean fixation time has no such interpretation.

  13. No difference in sexual dysfunction after transabdominal preperitoneal (TAPP) approach for inguinal hernia with fibrin sealant or tacks for mesh fixation

    DEFF Research Database (Denmark)

    Pommergaard, H C; Burcharth, J; Andresen, K

    2017-01-01

    BACKGROUND: Postoperative sexual dysfunction in relation to laparoscopic groin hernia surgery may be related to methods of mesh fixation. However, this has not been investigated earlier. Moreover, results regarding sexual dysfunction in females have not been reported systematically. The aim...... of this study was to compare fibrin sealant versus tacks for fixation of mesh regarding sexual dysfunction in males and females. METHODS: Using the Danish Hernia Database, patients operated laparoscopically for groin hernia with a transabdominal preperitoneal (TAPP) procedure with fibrin sealant or tacks...... for mesh fixation were sent a questionnaire regarding sexual dysfunction. Sexually active patients without recurrence were evaluated in this study. RESULTS: Pain during sexual activity was present in 115 of 1019 (11.3 %) males and 17 of 147 (11.6 %) females. There was no difference between fibrin sealant...

  14. Avascular Necrosis of Acetabulum: The Hidden Culprit of Resistant Deep Wound Infection and Failed Fixation of Fracture Acetabulum - A Case Report.

    Science.gov (United States)

    K, Kandhari V; M, Desai M; S, Bava S; N, Wade R

    2015-01-01

    Chances of avascular necrosis of acetabulum are rare as it enjoys a rich blood supply. But cases of post - traumatic avascular necrosis of acetabulum following fracture of posterior column have been well documented. Importance of identifying and suspecting the avascular necrosis of acetabulum is essential in cases of failed fixation of fracture acetabulum, previously operated using extensile approach to acetabulum; either extended anterior ilio - femoral or tri - radiate approach. Such patients usually present with repeated deep bone infection or with early failure of fixation with aseptic loosening and migration of its components. We present a similar case. 40 years female presented with inadequately managed transverse fracture of left acetabulum done by anterior extended ilio-inguinal approach. The fixation failed. She presented 6 months later with painful hip. Cemented total hip replacement was performed with reconstruction of acetabulum by posterior column plating. Six months postoperatively patient presented with dislodgement of cup, pelvic discontinuity and sinus in the thigh. Two stage revision surgery was planned. First implant, removal; debridement and antibiotic spacer surgery was performed. At second stage of revision total hip replacement, patient had Paprosky grade IIIb defect in acetabulum. Spacer was removed through the posterior approach. Anterior approach was taken for anterior plating. Intra-operatively external iliac pulsations were found to be absent so procedure was abandoned after expert opinion. Postoperatively digital subtraction angiography demonstrated a chronic block in the external iliac artery and corona mortis was the only patent vascular channel providing vascular to the left lower limb. Thus, peripheral limb was stealing blood supply from the acetabulum to maintain perfusion. Patient was ultimately left with pelvic discontinuity, excision arthroplasty and pseudoarthrosis of the left hip. Avascular necrosis of acetabulum is a rare

  15. Covering one eye in fixation-disparity measurement causes slight movement of fellow eye

    NARCIS (Netherlands)

    Simonsz, H. J.; Bour, L. J.

    1991-01-01

    In the subjective measurement of fixation disparity (FD), the subject fuses contours presented in the peripheral macular areas of both eyes (fusion lock). The position of the eyes relative to each other is monitored by means of two haploscopically seen vertical lines presented in the central macular

  16. A study for the biological CO2 fixation and utilization system

    International Nuclear Information System (INIS)

    Otsuki, T.

    2001-01-01

    Increased CO 2 in the atmosphere is such a serious problem for mankind that many research and development approaches are implemented to reduce CO 2 emissions. One is a biological CO 2 fixation using the photosynthetic function of microalgae like Chlorella and Synechocystis sp. The target of the project is to achieve a CO 2 fixation rate of 50 g CO 2 /m 2 ·d, which is 10 times as large as that of the temperate forest. The purpose of this study is to clarify the possibilities of the biological CO 2 fixation system in view of the CO 2 balance, energy balance, and payback period. The amount of CO 2 fixation of the system should be larger than the emission of CO 2 by operating. Furthermore, the energy consumption of the system should also be less than the biochemical energy (enthalpy) of glucose, which is made by photosynthesis. After CO 2 fixation was completed by the microalgae, the biomass must be utilized practically for many markets and the initial investment in the system construction could be regained

  17. Comparison of cemented and uncemented fixation in total knee arthroplasty.

    Science.gov (United States)

    Brown, Thomas E; Harper, Benjamin L; Bjorgul, Kristian

    2013-05-01

    As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options. Copyright 2013, SLACK Incorporated.

  18. Immunohistochemistry of colorectal cancer biomarker phosphorylation requires controlled tissue fixation.

    Directory of Open Access Journals (Sweden)

    Abbey P Theiss

    Full Text Available Phosphorylated signaling molecules are biomarkers of cancer pathophysiology and resistance to therapy, but because phosphoprotein analytes are often labile, poorly controlled clinical laboratory practices could prevent translation of research findings in this area from the bench to the bedside. We therefore compared multiple biomarker and phosphoprotein immunohistochemistry (IHC results in 23 clinical colorectal carcinoma samples after either a novel, rapid tissue fixation protocol or a standard tissue fixation protocol employed by clinical laboratories, and we also investigated the effect of a defined post-operative "cold" ischemia period on these IHC results. We found that a one-hour cold ischemia interval, allowed by ASCO/CAP guidelines for certain cancer biomarker assays, is highly deleterious to certain phosphoprotein analytes, specifically the phosphorylated epidermal growth factor receptor (pEGFR, but shorter ischemic intervals (less than 17 minutes facilitate preservation of phosphoproteins. Second, we found that a rapid 4-hour, two temperature, formalin fixation yielded superior staining in several cases with select markers (pEGFR, pBAD, pAKT compared to a standard overnight room temperature fixation protocol, despite taking less time. These findings indicate that the future research and clinical utilities of phosphoprotein IHC for assessing colorectal carcinoma pathophysiology absolutely depend upon attention to preanalytical factors and rigorously controlled tissue fixation protocols.

  19. EXPERIMENTAL APPROVAL OF COMBINED FIXATION FOR FEMUR LENGTHENING

    Directory of Open Access Journals (Sweden)

    M. A. Stepanov

    2017-01-01

    Full Text Available Elimination of congenital shortening of lower limb still remains a complex and unsolved orthopaedic task which requires an improved fixation technique as well as adjusted tactics of treatment and rehabilitation procedures.Purpose of the study — experimental approval of femur lengthening technique by external fixation with Ilizarov apparatus and internal fixation by plate.Materials and methods. Femur lengthening was performed in 6 mongrel dogs. Average animal age was 1,5±0,3 years, average weight — 20±5 kg, femur length — 22±2 sm. External apparatus with two supports and a titanium plate of an original design were applied under general anesthesia on the right femur of animals. Lengthening was performed manually at a rate of1 mm per day in 4 stages at a distance of 10% from initial segment length. External apparatus was removed on the last day of distraction after locking the plate. X-ray examination was done on the day of surgery, in 7, 14 and 25 days from the onset of distraction as well as in 14, 30, 60 and 90 days after completion of distraction and removal of external apparatus. Three animals were taken out of experiment in 30 days of fixation, remaining three animals — in 90 days. After euthanasia the authors performed autopsy of the organic femur complex and tissues contacting the plate.Results. The use of operated limb was not restricted during the whole distraction period. The authors observed first roentgenological signs of distraction osteogenesis on 7th day of lengthening. By the end of distraction period, at 25th day, shadows of regenerates demonstrated longitudinal striated structures in all cases. Median lucency area of 1–5 mm was located diagonally and across the regenerate or was intermittent. In 60 days of fixation X-rays demonstrated homogeneous regenerate. External fixation index was 13,9±1,5 days/sm (p≤0,05. The authors observed no cases of implants fracture or deformity during the experiment

  20. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.

    Science.gov (United States)

    Wirtz, C; Abbassi, F; Evangelopoulos, D S; Kohl, S; Siebenrock, K A; Krüger, A

    2013-06-01

    Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. Early results for PF-LCP osteosynthesis show major

  1. Bilateral spontaneous subluxation of scleral-fixated intraocular lenses.

    Science.gov (United States)

    Assia, Ehud I; Nemet, Arie; Sachs, Dani

    2002-12-01

    Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.

  2. Transforaminal lumbar interbody fusion using unilateral pedicle screw fixation plus contralateral translaminar facet screw fixation in lumbar degenerative diseases.

    Science.gov (United States)

    Liu, Fubing; Jiang, Chun; Cao, Yuanwu; Jiang, Xiaoxing; Feng, Zhenzhou

    2014-07-01

    Transforaminal lumbar interbody fusion (TLIF) has been used in lumbar degenerative diseases. Some researchers have applied unilateral fixation in TLIF to reduce operational trauma without compromising the clinical outcome, but it is always suspected biomechanically unstable. The supplementary contralateral translaminar facet screw (cTLFS) seemed to be able to overcome the inherent drawbacks of unilateral pedicle screw (uPS) fixation theoretically. This study evaluates the safety, feasibility and efficacy of TLIF using uPS with cTLFS fixation in the treatment of lumbar degenerative diseases (LDD). 50 patients (29 male) underwent the aforementioned surgical technique for their LDD between December 2009 and April 2012. The results were evaluated based on visual analogue scale (VAS) of the leg and back, Japanese Orthopedic Association (JOA) score and Oswestry Disability Index (ODI) were recorded. The radiographic examinations in form of X-ray, computed tomography (CT) or magnetic resonance imaging was done preoperatively and 1 week, 3 months, 6 months, 12 months and 24 months postoperatively. The student t-test was used for comparison between the preoperative values and postoperative counterparts. P degenerative diseases short termly.

  3. Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The ′fix and shift′ technique

    Directory of Open Access Journals (Sweden)

    P R Ramasamy

    2017-01-01

    Full Text Available Background: Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Materials and Methods: Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement. Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Results: Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Conclusion: Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

  4. Sacroiliac screw fixation: A mini review of surgical technique

    Directory of Open Access Journals (Sweden)

    Hernando Raphael Alvis-Miranda

    2014-01-01

    Full Text Available The sacral percutaneous fixation has many advantages but can be associated with a significant exposure to X-ray radiation. Currently, sacroiliac screw fixation represents the only minimally invasive technique to stabilize the posterior pelvic ring. It is a technique that should be used by experienced surgeons. We present a practical review of important aspects of this technique.

  5. Health-related quality of life and anemia in hospitalized patients with heart failure

    NARCIS (Netherlands)

    Kraai, I. H.; Luttik, M. L. A.; Johansson, P.; De Jong, R. M.; Van Veldhuisen, D. J.; Hillege, H. L.; Jaarsma, T.

    2012-01-01

    Background: Anemia is a serious and highly prevalent co-morbidity in chronic heart failure (HF) patients. Its influence on health-related quality of life (HR-QoL) has rarely been studied, and no data is available regarding the role it plays in hospitalized HF patients. Methods: Baseline data from

  6. Health-related quality of life and anemia in hospitalized patients with heart failure

    NARCIS (Netherlands)

    Kraai, Imke H.; Luttik, Marie Louise; Johansson, P.; van Veldhuisen, Dirk J.; Hillege, Hans L.; de Jong, Remco; Jaarsma, Tiny

    2012-01-01

    BACKGROUND: Anemia is a serious and highly prevalent co-morbidity in chronic heart failure (HF) patients. Its influence on health-related quality of life (HR-QoL) has rarely been studied, and no data is available regarding the role it plays in hospitalized HF patients. METHODS: Baseline data from

  7. Use of 15N methodology to assess biological nitrogen fixation

    International Nuclear Information System (INIS)

    Hardarson, G.

    1990-01-01

    One of the most important characteristics of legumes are their ability in symbiosis with Rhizobium bacteria to fix atmospheric nitrogen for growth. For proper management and a full realization of the benefits of this plant-microbial association, it is necessary to estimate how much nitrogen is fixed under different conditions in the field. It is only after this is known that various factors can be manipulated so as to increase the amount and proportion of N a plant derives from biological fixation. A suitable method for accurately measuring the amount of N crops derive from fixation is therefore an important requirement in any programme aimed at maximizing biological nitrogen fixation. There are several methods available to measure N 2 fixation (Bergersen, 1980) based on (1) increment in N yield and plant growth, (2) nitrogen balance (3) acetylene reduction and (4) the use of isotopes of N. Only isotopic methods will be illustrated here. 20 refs, 2 figs, 9 tabs

  8. Functional ecology of free-living nitrogen fixation: A contemporary perspective

    Science.gov (United States)

    Reed, Sasha C.; Cleveland, Cory C.; Townsend, Alan R.

    2011-01-01

    Nitrogen (N) availability is thought to frequently limit terrestrial ecosystem processes, and explicit consideration of N biogeochemistry, including biological N2 fixation, is central to understanding ecosystem responses to environmental change. Yet, the importance of free-living N2 fixation—a process that occurs on a wide variety of substrates, is nearly ubiquitous in terrestrial ecosystems, and may often represent the dominant pathway for acquiring newly available N—is often underappreciated. Here, we draw from studies that investigate free-living N2 fixation from functional, physiological, genetic, and ecological perspectives. We show that recent research and analytical advances have generated a wealth of new information that provides novel insight into the ecology of N2 fixation as well as raises new questions and priorities for future work. These priorities include a need to better integrate free-living N2 fixation into conceptual and analytical evaluations of the N cycle's role in a variety of global change scenarios.

  9. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  10. Fixation of a human rib by an intramedullary telescoping splint anchored by bone cement.

    Science.gov (United States)

    Liovic, Petar; Šutalo, Ilija D; Marasco, Silvana F

    2016-09-01

    A novel concept for rib fixation is presented that involves the use of a bioresorbable polymer intramedullary telescoping splint. Bone cement is used to anchor each end of the splint inside the medullary canal on each side of the fracture site. In this manner, rib fixation is achieved without fixation device protrusion from the rib, making the splint completely intramedullary. Finite element analysis is used to demonstrate that such a splint/cement composite can preserve rib fixation subjected to cough-intensity force loadings. Computational fluid dynamics and porcine rib experiments were used to study the anchor formation process required to complete the fixation.

  11. Mean-field approximations of fixation time distributions of evolutionary game dynamics on graphs

    Science.gov (United States)

    Ying, Li-Min; Zhou, Jie; Tang, Ming; Guan, Shu-Guang; Zou, Yong

    2018-02-01

    The mean fixation time is often not accurate for describing the timescales of fixation probabilities of evolutionary games taking place on complex networks. We simulate the game dynamics on top of complex network topologies and approximate the fixation time distributions using a mean-field approach. We assume that there are two absorbing states. Numerically, we show that the mean fixation time is sufficient in characterizing the evolutionary timescales when network structures are close to the well-mixing condition. In contrast, the mean fixation time shows large inaccuracies when networks become sparse. The approximation accuracy is determined by the network structure, and hence by the suitability of the mean-field approach. The numerical results show good agreement with the theoretical predictions.

  12. Neonate With Severe Heart Failure Related to Vein of Galen Malformation

    Directory of Open Access Journals (Sweden)

    Meng-Yu Chen

    2010-08-01

    Full Text Available We report a full-term female neonate who presented with respiratory distress and severe heart failure soon after birth. Heart failure secondary to perinatal infection was initially suspected. Subsequent echocardiography revealed aortic runoff, which led to consideration of an intracranial vascular abnormality. Ultrasound and magnetic resonance imaging of the brain confirmed a diagnosis of vein of Galen aneurismal malformation (VGAM. Endovascular coil embolization of the vascular anomaly was performed, resulting in improvement of heart failure. VGAM should be considered in the differential diagnosis of neonatal congestive heart failure with a structurally normal heart. Urgent endovascular embolization and aggressive medical treatment of heart failure improve prognosis in neonatal VGAM.

  13. Treatment of complex osteoarticular injuries of the elbow with external unilateral articulated fixator

    International Nuclear Information System (INIS)

    Cuellar Gallo, Lazaro; Portilla Carrillo, Armando; Calderon Uribe, Oscar; Calvache Currea, Gustavo Adolfo; Satizabal Azuero, Carlos Arnulfo

    2001-01-01

    Previous observations suggest that conventional treatment of complex injuries about the elbow such as open; reduction and internal Fixation might lead, to bad functional outcome. The authors present a descriptive, observational and prospective study of a series of cases, on 8 patients, average age 37.8 years (25-28 years) 6 men and 2 women with complex injury of the elbow. Due to trauma which etiology is summarized as follows intraarticular comminuted open fracture secondary to gunshot wound 5 patients (62.5%); luxofracture 2 patients (25%), lntraarticular comminuted closed fracture 1 patient (12.5%). The patients where followed for 8 to 20 months. Were performed en 75% of patients open reduction, internal fixation of radial resection of radial head en 25% when comminute fracture of the head was found. All patients were treated with an external unilateral articulated fixation on the elbow, in order to protect the internal fixation, allow early joint motion and give early mobility. All patients were evaluated with Mayo scale, obtaining good results, with externals fixation treatment. In one case (12.5%) a dyaphiseal fracture of the humerus, occurred as an inherent complication secondary to the use of the external fixation, after it's withdrawal. This patient was treated with open reduction and internal fixation of the fracture, without significant impairment of the final result. Early results suggest that the use of unilateral articulated external fixator for the treatment of complex fractures about the elbow has great advantages over the other treatment techniques, such as the early motion of the elbow, dynamic protection of the internal fixation and preservation of the articulate stability, even when ligament injury is present

  14. [Comparing clinical effects of titanic elastic nail and locking compression pine fixation in treating subtrochanteric fractures in older children].

    Science.gov (United States)

    Zhu, Kang-xiang; Yin, Shan-qing

    2013-12-01

    To explore optimal choice of surgical treatment for subtrochanteric fractures in older children. A retrospective study of 36 older children with subtrochanteric fractures was performed between January 2010 and January 2012. Among them, 18 patients (11 males and 7 females) aged from 7 to 13 years old with an average of 9.4 were treated with titanic elastic nail (TEN) fixation, 4 cases were Type II A, 3 cases were II B, 2 cases were II C, 4 cases were III A, 3 cases were III B according to Seinsheimer classification. Eighteen patients (10 males and 8 females) aged was from 8 to 13 years with an average of 9.6 were treated with locking compression pine (LCP) fixation, and 3 cases were Type II A, 4 cases were II B, 3 cases were II C, 4 cases were IIIA, 2 cases were III B. Fracture healing time, postoperative complications (including wound infection, failure and breakage of internal fixtion, deformities of angular on the sagittal view, deformities of coxa vara) and recovery of hip joint function were observed and recorded. All children were followed up from 15 to 36 months with an average of 21. Fracture were all healed, the time ranged from 7 to 16 weeks (mean 9.5). Three cases in TEN group occurred mild deformities of angular on the sagittal view, 3 cases occurred deformities of coxa vara and 2 cases occurred limb shortening; while 1 case occurred mild deformities of angular on the sagittal view, and no deformities of coxa vara and limb shortening occurred in LCP group. No early close of epiphyseal injury, avascular necrosis of femoral head occurred. Clinical efficacy were evaluated by Sanders standard, 14 cases got excellent results, 3 cases were moderate in LCP group, while 9 cases in excellent, 4 in moderate in TEN group. There were no significant differences between two group in recovery of hip joint function and complications. For the treatment of subtrochanteric fractures in older children,the efficacy of LCP fixation is better than that of TFN fixation, which

  15. Management and quantification of nitrogen fixation in Leucaena leucocephala

    International Nuclear Information System (INIS)

    Safo, E.Y.

    1998-01-01

    The effects of pruning and age on N 2 fixation were studied using Leucaena leucocephala isoline K28, with Cassia siamea as the non-N 2 -fixing reference species, at a site of degraded soil fertility typical of much of the farming land in Ghana. The 15 N-dilution method was used to estimate N2 fixation. Cassia siamea consistently produced higher total biomass and total N yields than did L. leucocephala. The mean value for the fraction of N derived from fixation (%Ndfa) was higher for pruned L. leucocephala (36%) than for unpruned trees (18%). There was some underestimation of N 2 fixation as a result of using C. siamea as the reference, and because root N-contents were not determined. Strong, significant linear correlations were observed between foliar and whole-tree (weighted average) percent 15 N atom excess in unpruned L. leucocephala and C. siamea, suggesting that foliar 15 N enrichment can be used to accurately estimate %Ndfa. The results demonstrated that the 15 N-enrichment methodology can provide meaningful estimates of %Ndfa and total N 2 fixed for mixed tree plantations under field conditions, when adequate spacing is provided. (author)

  16. Fixation and saliency during search of natural scenes: the case of visual agnosia.

    Science.gov (United States)

    Foulsham, Tom; Barton, Jason J S; Kingstone, Alan; Dewhurst, Richard; Underwood, Geoffrey

    2009-07-01

    Models of eye movement control in natural scenes often distinguish between stimulus-driven processes (which guide the eyes to visually salient regions) and those based on task and object knowledge (which depend on expectations or identification of objects and scene gist). In the present investigation, the eye movements of a patient with visual agnosia were recorded while she searched for objects within photographs of natural scenes and compared to those made by students and age-matched controls. Agnosia is assumed to disrupt the top-down knowledge available in this task, and so may increase the reliance on bottom-up cues. The patient's deficit in object recognition was seen in poor search performance and inefficient scanning. The low-level saliency of target objects had an effect on responses in visual agnosia, and the most salient region in the scene was more likely to be fixated by the patient than by controls. An analysis of model-predicted saliency at fixation locations indicated a closer match between fixations and low-level saliency in agnosia than in controls. These findings are discussed in relation to saliency-map models and the balance between high and low-level factors in eye guidance.

  17. Predicting Eye Fixations on Complex Visual Stimuli Using Local Symmetry

    NARCIS (Netherlands)

    Kootstra, Geert; de Boer, Bart; Schomaker, Lambertus

    Most bottom-up models that predict human eye fixations are based on contrast features. The saliency model of Itti, Koch and Niebur is an example of such contrast-saliency models. Although the model has been successfully compared to human eye fixations, we show that it lacks preciseness in the

  18. Predicting eye fixations on complex visual stimuli using local symmetry

    NARCIS (Netherlands)

    Kootstra, G.; de Boer, B.; Schomaker, L.R.B.

    2011-01-01

    Most bottom-up models that predict human eye fixations are based on contrast features. The saliency model of Itti, Koch and Niebur is an example of such contrast-saliency models. Although the model has been successfully compared to human eye fixations, we show that it lacks preciseness in the

  19. Transarticular fixation with cortical screws combined with dorsal laminectomy and partial discectomy as surgical treatment of degenerative lumbosacral stenosis in 17 dogs: clinical and computed tomography follow-up.

    Science.gov (United States)

    Golini, Lorenzo; Kircher, Patrick R; Lewis, Fraser I; Steffen, Frank

    2014-05-01

    To describe clinical outcome and technical outcome assessed using computed tomography (CT) in dogs with degenerative lumbosacral stenosis (DLSS) treated by dorsal laminectomy, partial discectomy, and transarticular screw fixation. Retrospective observational case series. Dogs with DLSS (n = 17). Dogs with neurologic and magnetic resonance imaging (MRI) findings compatible with DLSS treated by dorsal laminectomy, partial discectomy and transarticular screw fixation were enrolled. Pre- and postoperative neurologic status was compared. Lumbosacral (LS) angle in extension and misalignment in preoperative MRI were compared with the postoperative CT. Residual mobility of the LS joint after fixation was also evaluated. Status of screws, presence of new bone formation over screw heads/articular facets and presence of adjacent segment disease (ASD) were assessed. Median CT follow-up was 12 months. Clinical improvement was seen in 13 dogs, 2 dogs had intermittent LS pain, and 2 dogs needed revision surgery. In 5 dogs, screws were either pulled out or broken. Reduction of LS angle in extension and misalignment was achieved. Residual mobility of the LS segment was present and ASD was not recognized. Transarticular screw fixation in dogs with DLSS is associated with a considerable number of technical failures and does not result in rigid stabilization; however, this did not significantly adversely influence clinical outcome. © Copyright 2014 by The American College of Veterinary Surgeons.

  20. Nonphotosynthetic CO2 fixation by alfalfa (Medicago sativa L.) roots and nodules

    International Nuclear Information System (INIS)

    Anderson, M.P.; Heichel, G.H.; Vance, C.P.

    1987-01-01

    The dependence of alfalfa (Medicago sativa L.) root and nodule nonphotosynthetic CO 2 fixation on the supply of currently produced photosynthate and nodule nitrogenase activity was examined a various times after phloem-girdling and exposure of nodules to Ar:O 2 . Phloem-girdling was effected 20 hours and exposure to Ar:O 2 was effected 2 to 3 hours before initiation of experiments. Nodule and root CO 2 fixation rates of phloem-girdled plants were reduced to 38 and 50%, respectively, of those of control plants. Exposure to Ar:O 2 decreased nodule CO 2 fixation rates to 45%, respiration rates to 55%, and nitrogenase activities to 51% of those of the controls. The products of nodule CO 2 fixation were exported through the xylem to the shoot mainly as amino acids within 30 to 60 minutes after exposure to 14 CO 2 . In contrast to nodules, roots exported very little radioactivity, and most of the 14 C was exported as organic acids. The nonphotosynthetic CO 2 fixation rate of roots and nodules averaged 26% of the gross respiration rate, i.e. the sum of net respiration and nonphotosynthetic CO 2 assimilation. Nodules fixed CO 2 at a rate 5.6 times that of roots, but since nodules comprised a small portion of root system mass, roots accounted for 76% of the nodulated roots system CO 2 fixation. The results indicate that nodule CO 2 fixation in alfalfa is associated with N assimilation

  1. The Effect of Suture Anchor Insertion Angle on Calcaneus Pullout Strength: Challenging the Deadman's Angle.

    Science.gov (United States)

    Weiss, William M; Saucedo, Ramon P; Robinson, John D; Lo, Chung-Chieh Jason; Morris, Randal P; Panchbhavi, Vinod K

    2017-10-01

    Refractory cases of Achilles tendinopathy amenable to surgery may include reattachment of the tendon using suture anchors. However, there is paucity of information describing the optimal insertion angle to maximize the tendon footprint and anchor stability in the calcaneus. The purpose of this investigation is to compare the fixation strength of suture anchors inserted at 90° and 45° (the Deadman's angle) relative to the primary compressive trabeculae of the calcaneus. A total of 12 matched pairs of adult cadaveric calcanei were excised and potted to approximate their alignment in vivo. Each pair was implanted with 5.5-mm bioabsorbable suture anchors placed either perpendicular (90°) or oblique (45°) to the primary compressive trabeculae. A tensile load was applied until failure of anchor fixation. Differences in failure load and stiffness between anchor fixation angles were determined by paired t-tests. No significant differences were detected between perpendicular and oblique suture anchor insertion relative to primary compressive trabeculae in terms of load to failure or stiffness. This investigation suggests that the fixation strength of suture anchors inserted perpendicular to the primary compression trabeculae and at the Deadman's angle are possibly comparable. Biomechanical comparison study.

  2. Nitrogen supply of crops by biological nitrogen fixation. 2

    International Nuclear Information System (INIS)

    Jensen, E.S.; Andersen, A.J.; Soerensen, H.; Thomsen, J.D.

    1985-02-01

    In the present work the contributions from combined N-sources and symbiotic nitrogen fixation to the nitrogen supply of field-grown peas and field beans were evaluated by means of 15 N fertilizer dilution. The effect of N-fertilizer, supplied at sowing and at different stages of plant development, on nitrogen fixation, yield and protein production in peas, was studied in pot experiments. (author)

  3. [Treatment of femoral neck fracture--preference to internal fixation].

    Science.gov (United States)

    Minato, Izumi

    2011-03-01

    In the guidelines for the treatment of femoral neck fracture, prosthetic replacement is recommended in displaced one and internal fixation is in undisplaced one. However, in the long view, survived femoral head after internal fixation can be superior to prosthesis which will deteriorate as time goes by. Surgical method should be considered not only by type of fracture but general status of the patient.

  4. Immune mediated liver failure.

    Science.gov (United States)

    Wang, Xiaojing; Ning, Qin

    2014-01-01

    Liver failure is a clinical syndrome of various etiologies, manifesting as jaundice, encephalopathy, coagulopathy and circulatory dysfunction, which result in subsequent multiorgan failure. Clinically, liver failure is classified into four categories: acute, subacute, acute-on-chronic and chronic liver failure. Massive hepatocyte death is considered to be the core event in the development of liver failure, which occurs when the extent of hepatocyte death is beyond the liver regenerative capacity. Direct damage and immune-mediated liver injury are two major factors involved in this process. Increasing evidence has suggested the essential role of immune-mediated liver injury in the pathogenesis of liver failure. Here, we review the evolved concepts concerning the mechanisms of immune-mediated liver injury in liver failure from human and animal studies. Both innate and adaptive immunity, especially the interaction of various immune cells and molecules as well as death receptor signaling system are discussed. In addition, we highlight the concept of "immune coagulation", which has been shown to be related to the disease progression and liver injury exacerbation in HBV related acute-on-chronic liver failure.

  5. Deepwater Nitrogen Fixation: Who's Doing it, Where, and Why?

    Science.gov (United States)

    Montoya, J. P.; Weber, S.; Vogts, A.; Voss, M.; Saxton, M.; Joye, S. B.

    2016-02-01

    Nitrogen availability frequently limits marine primary production and N2-fixation plays an important role in supporting biological production in surface waters of many oligotrophic regions. Although subsurface waters typically contain high concentrations of nitrate and other nutrients, measurements from a variety of oceanic settings show measurable, and at times high rates of N2-fixation in deep, dark waters below the mixed layer. We have explored the distribution of N2-fixation throughout the water column of the Gulf of Mexico (GoM) during a series of cruises beginning shortly after the Deepwater Horizon (DWH) spill in 2010 and continuing at roughly annual intervals. These cruises allowed us to sample oligotrophic waters across a range of depths, and to explore the connections between the C and N cycles mediated by release of oil and gas (petrocarbon) from natural seeps as well as anthropogenic sources (e.g., the DWH). We used stable isotope abundances (15N and 13C) in particles and zooplankton in combination with experimental measurements of N2-fixation and CH4 assimilation to assess the contribution of oil- and gas-derived C to the pelagic food web, and the impact of CH4 releases on the pelagic C and N cycles. Our isotopic measurements document the movement of petrocarbon into the pelagic food web, and our experiments revealed that high rates of N2-fixation were widespread in deep water immediately after the DWH incident, and restricted to the vicinity of natural seeps in subsequent years. Unfortunately, these approaches provided no insight into the organisms actually responsible for N2-fixation and CH4-assimilation. We used nano-scale Secondary Ion Mass Spectrometry (nanoSIMS) to image the organisms responsible for these processes, and molecular approaches to explore the diversity of methanotrophs and diazotrophs present in the system. The ability to resolve isotopic distributions on the scale of individual cells is a critical part of bridging the gap between

  6. Direct and indirect costs of dinitrogen fixation in Crocosphaera watsonii WH8501 and possible implications for the nitrogen cycle

    Directory of Open Access Journals (Sweden)

    Tobias eGroßkopf

    2012-07-01

    Full Text Available The recent detection of heterotrophic nitrogen (N2 fixation in deep waters of the southern Californian and Peruvian OMZ questions our current understanding of marine N2 fixation as a process confined to oligotrophic surface waters of the oceans. In experiments with Crocosphaera watsonii WH8501, a marine unicellular diazotrophic (N2-fixing cyanobacterium, we demonstrated that the presence of high nitrate concentrations (up to 800 µM had no inhibitory effect on growth and N2 fixation over a period of two weeks. In contrast, the environmental oxygen concentration significantly influenced rates of N2 fixation and respiration, as well as carbon and nitrogen cellular content of C. watsonii over a 24 hour period. Cells grown under lowered oxygen atmosphere (5% had a higher nitrogenase activity and respired less carbon during the dark cycle than under normal oxygen atmosphere (20%. Respiratory oxygen drawdown during the dark period could be fully explained (104% by energetic needs due to basal metabolism and N2 fixation at low oxygen, while at normal oxygen these two processes could only account for 40% of the measured respiration rate. Our results revealed that under normal oxygen concentration most of the energetic costs during N2 fixation (~60% are not derived from the process of N2 fixation per se but rather from the indirect costs incurred for the removal of intracellular oxygen or by the reversal of oxidative damage (e.g. nitrogenase de novo synthesis. Theoretical calculations suggest a slight energetic advantage of N2 fixation relative to assimilatory nitrate uptake for heterotrophic and phototrophic growth, when oxygen supply is in balance with the oxygen requirement for cellular respiration (i.e. energy generation for basal metabolism and N2 fixation. Taken together our results imply the existence of a niche for diazotrophic organisms inside oxygen minimum zones, which are predicted to further expand in the future ocean.

  7. Benthic dinitrogen fixation traversing the oxygen minimum zone off Mauritania (NW Africa)

    DEFF Research Database (Denmark)

    Gier, Jessica; Löscher, Carolin R.; Dale, Andrew W.

    2017-01-01

    metabolisms, such as sulfate reduction. In the present study, benthic N2 fixation together with sulfate reduction and other heterotrophic metabolisms were investigated at six station between 47 and 1,108 m water depth along the 18°N transect traversing the highly productive upwelling region known...... as Mauritanian oxygen minimum zone (OMZ). Bottom water oxygen concentrations ranged between 30 and 138 μM. Benthic N2 fixation determined by the acetylene reduction assay was detected at all stations with highest rates (0.15 mmol m-2 d-1) on the shelf (47 and 90 m water depth) and lowest rates (0.08 mmol m-2 d-1......) below 412 m water depth. The biogeochemical data suggest that part of the N2 fixation could be linked to sulfate- and iron-reducing bacteria. Molecular analysis of the key functional marker gene for N2 fixation, nifH, confirmed the presence of sulfate- and iron-reducing diazotrophs. High N2 fixation...

  8. Indications and outcome of Open Reduction and Internal Fixation of ...

    African Journals Online (AJOL)

    Background: Open reduction and internal fixation (ORIF) is a well-established surgical treatment of fractures worldwide. However, the indications and modes of stabilization of long bone fractures vary and are evolving .The general trend now is towards fixation with locked intramedullary nail (i.m nail) rather than plate and ...

  9. Dynamic Programming for Re-Mapping Noisy Fixations in Translation Tasks

    DEFF Research Database (Denmark)

    Carl, Michael

    2013-01-01

    possible fixated symbols, including those on the line above and below the naïve fixation mapping. In a second step a dynamic programming algorithm applies a number of heuristics to find the best path through the lattice, based on the probable distance in characters, in words and in pixels between...

  10. Management of Subcondylar Fracture through Intraoral Approach with Rigid Internal Fixation.

    Science.gov (United States)

    Patil, Ravi S; Gudi, Santosh S

    2011-09-01

    In Oral and Maxillofacial Surgery, the majority of the condylar fractures are treated by closed reduction with generally satisfactory long term results. But in such cases of closed reduction, patient will be uncomfortable owing to long term application of inter maxillary fixation (IMF). Where as, Disadvantages of extra oral open reduction and fixation of condylar fracture includes facial nerve damage, facial scars etc. which are surely eliminated by the intraoral reduction and rigid fixation. The present study was conducted to determine the efficacy of reduction and fixation of low sub-condylar fractures through intra-oral approach. In this study, ten patients with low sub-condylar fracture, reported to department of Oral and Maxillofacial Surgery. P.M.N.M. Dental College and Hospital Bagalkot were included. These patients were treated by open reduction and internal fixation through intra-oral approach. All the patients were evaluated postoperatively for mouth opening, occlusion and mandibular deviation with regular radiographic examination for 6 weeks. All operated patients followed for 6 weeks, maximum mouth opening was more than 40 mm in seven patients (range from 40 to 50 mm) and less than 40 mm in three patients. Occlusion was satisfactory in all and none of the patients showed deviation of mandible on mouth opening. Statistical analysis showed that postoperative mouth opening was significant ('t' value = 7.88, 'P' = (0.000) value = 1.96, 'P' value (0.081), 0.05]. For occlusion standard photographs were obtained at sixth week and found minor occlusal corrections in two patients are treated by elastic traction for few days. Open reduction with internal fixation through intraoral approach has proved to be safe for early function and also effective by avoiding the patient discomfort due to long term intermaxillary fixation, psychological effect, facial nerve damage, facial scar and weight loss.

  11. Evaluation of options relative to the fixation and disposal of 14C-contaminated CO2 as CaCO3

    International Nuclear Information System (INIS)

    Croff, A.G.

    1976-04-01

    A paper study was conducted to determine the best method for fixing the 14 C-contaminated CO 2 resulting from an HTGR fuel block burner as CaCO 3 , and to determine the best methods for disposing of the CaCO 3 thus produced. The fixation method selected was the direct reaction of a Ca(OH) 2 slurry with the CO 2 . The least expensive disposal options which are likely to be acceptable appear to be the shallow-land burial of either drummed CaCO 3 solid (total cost = $18.47/kg heavy metal) or drummed CaCO 3 concreted with cement (total cost = $43.33/kg heavy metal). Neither placing the CO 2 fixation process before the Kr removal process nor separating the bulk of the graphite fuel block from the fuel particles is attractive on both technical and economic grounds. However, reduction of the HTGR fuel nitrogen content appears to be a more attractive method of reducing the 14 C release rate

  12. Studies in Sri Lanka on cowpea: N2 fixation, growth, yield, and effects on cereals

    International Nuclear Information System (INIS)

    Senaratne, R.; Dayatilake, G.A.; Subasinghe, S.

    1998-01-01

    The impact of seed inoculation and N-fertilization on nodulation, plant dry-matter production, and seed yield was studied through a series of field experiments with cultivars of cowpea. In some instances there were positive growth responses to applied N, indicating the potential to improve N 2 fixation and yields by combining compatible genotypes and bradyrhizobial strains. Beneficial residual effects on growth of subsequent maize could not be related to N 2 fixation by the preceding cowpea. Although there was no evidence of direct transfer of N from cowpea to intercropped maize, there was greater efficiency of use of N for total crop production during intercropping

  13. Virtual haptic system for intuitive planning of bone fixation plate placement

    Directory of Open Access Journals (Sweden)

    Kup-Sze Choi

    2017-01-01

    Full Text Available Placement of pre-contoured fixation plate is a common treatment for bone fracture. Fitting of fixation plates on fractured bone can be preoperatively planned and evaluated in 3D virtual environment using virtual reality technology. However, conventional systems usually employ 2D mouse and virtual trackball as the user interface, which makes the process inconvenient and inefficient. In the paper, a preoperative planning system equipped with 3D haptic user interface is proposed to allow users to manipulate the virtual fixation plate intuitively to determine the optimal position for placement on distal medial tibia. The system provides interactive feedback forces and visual guidance based on the geometric requirements. Creation of 3D models from medical imaging data, collision detection, dynamics simulation and haptic rendering are discussed. The system was evaluated by 22 subjects. Results show that the time to achieve optimal placement using the proposed system was shorter than that by using 2D mouse and virtual trackball, and the satisfaction rating was also higher. The system shows potential to facilitate the process of fitting fixation plates on fractured bones as well as interactive fixation plate design.

  14. An in-vitro biomechanical study of different fixation techniques for the extended trochanteric osteotomy in revision THA.

    Science.gov (United States)

    Zhu, Zhonglin; Ding, Hui; Shao, Hongyi; Zhou, Yixin; Wang, Guangzhi

    2013-04-09

    The wire fixation and the cable grip fixation have been developed for the extended trochanteric osteotomy (ETO) in the revision of total hip arthroplasty (THA). Many studies reported the postoperative performance of the patients, but with little quantitative biomechanical comparison of the two fixation systems. An in-vitro testing approach was designed to record the loosening between the femoral bed and the greater trochanter after fixations. Ten cadaveric femurs were chosen in this study. Each femur underwent the THA, revision by ETO and fixations. The tension to the greater trochanter was from 0 to 500N in vertical and lateral direction, respectively. The translation and rotation of the greater trochanter with respect to the bony bed were captured by an optical tracking system. In the vertical tension tests, the overall translation of the greater trochanter was observed 0.4 mm in the cable fixations and 7.0 mm in the wire fixations. In the lateral tension tests, the overall motion of the greater trochanter was 2.0 mm and 1.2° in the cable fixations, while it was 6.2 mm and 5.3° in the wire fixations. The result was significantly different between the two fixation systems. The stability of the proximal femur after ETO using different fixations in the revision THA was investigated. The cable grip fixation was significantly more stable than the wire fixation.

  15. Database of diazotrophs in global ocean: abundance, biomass and nitrogen fixation rates

    Directory of Open Access Journals (Sweden)

    Y.-W. Luo

    2012-08-01

    Full Text Available Marine N2 fixing microorganisms, termed diazotrophs, are a key functional group in marine pelagic ecosystems. The biological fixation of dinitrogen (N2 to bioavailable nitrogen provides an important new source of nitrogen for pelagic marine ecosystems and influences primary productivity and organic matter export to the deep ocean. As one of a series of efforts to collect biomass and rates specific to different phytoplankton functional groups, we have constructed a database on diazotrophic organisms in the global pelagic upper ocean by compiling about 12 000 direct field measurements of cyanobacterial diazotroph abundances (based on microscopic cell counts or qPCR assays targeting the nifH genes and N2 fixation rates. Biomass conversion factors are estimated based on cell sizes to convert abundance data to diazotrophic biomass. The database is limited spatially, lacking large regions of the ocean especially in the Indian Ocean. The data are approximately log-normal distributed, and large variances exist in most sub-databases with non-zero values differing 5 to 8 orders of magnitude. Reporting the geometric mean and the range of one geometric standard error below and above the geometric mean, the pelagic N2 fixation rate in the global ocean is estimated to be 62 (52–73 Tg N yr−1 and the pelagic diazotrophic biomass in the global ocean is estimated to be 2.1 (1.4–3.1 Tg C from cell counts and to 89 (43–150 Tg C from nifH-based abundances. Reporting the arithmetic mean and one standard error instead, these three global estimates are 140 ± 9.2 Tg N yr−1, 18 ± 1.8 Tg C and 590 ± 70 Tg C, respectively. Uncertainties related to biomass conversion factors can change the estimate of geometric mean pelagic diazotrophic biomass in the global ocean by about ±70%. It was recently established that the most commonly applied method used to measure N2

  16. Taxonomic identity determines N2 fixation by canopy trees across lowland tropical forests.

    Science.gov (United States)

    Wurzburger, Nina; Hedin, Lars O

    2016-01-01

    Legumes capable of fixing atmospheric N2 are abundant and diverse in many tropical forests, but the factors determining ecological patterns in fixation are unresolved. A long-standing idea is that fixation depends on soil nutrients (N, P or Mo), but recent evidence shows that fixation may also differ among N2-fixing species. We sampled canopy-height trees across five species and one species group of N2-fixers along a landscape P gradient, and manipulated P and Mo to seedlings in a shadehouse. Our results identify taxonomy as the major determinant of fixation, with P (and possibly Mo) only influencing fixation following tree-fall disturbances. While 44% of trees did not fix N2, other trees fixed at high rates, with two species functioning as superfixers across the landscape. Our results raise the possibility that fixation is determined by biodiversity, evolutionary history and species-specific traits (tree growth rate, canopy stature and response to disturbance) in the tropical biome. © 2015 John Wiley & Sons Ltd/CNRS.

  17. The role of bone SPECT/CT in the evaluation of lumbar spinal fusion with metallic fixation devices

    DEFF Research Database (Denmark)

    Damgaard, Morten; Nimb, Lars; Madsen, Jan L

    2010-01-01

    PURPOSE: It is difficult to evaluate the stability of the lumbar spondylodesis with metallic fixation devices by conventional imaging methods such as radiography or magnetic resonance imaging. It is unknown whether single photon emission computed tomography/computed tomography (SPECT/CT) may......, whereas in 1 case loose pedicle screws were detected at a wrong vertebral level. CONCLUSION: SPECT/CT may be useful to detect a lack of fixation of the metallic implants, and hence instability of the spondylodesis by evaluating the focal bone mineralization activity in relation to the pedicle screws....

  18. High level waste fixation in cermet form

    International Nuclear Information System (INIS)

    Kobisk, E.H.; Aaron, W.S.; Quinby, T.C.; Ramey, D.W.

    1981-01-01

    Commercial and defense high level waste fixation in cermet form is being studied by personnel of the Isotopes Research Materials Laboratory, Solid State Division (ORNL). As a corollary to earlier research and development in forming high density ceramic and cermet rods, disks, and other shapes using separated isotopes, similar chemical and physical processing methods have been applied to synthetic and real waste fixation. Generally, experimental products resulting from this approach have shown physical and chemical characteristics which are deemed suitable for long-term storage, shipping, corrosive environments, high temperature environments, high waste loading, decay heat dissipation, and radiation damage. Although leach tests are not conclusive, what little comparative data are available show cermet to withstand hydrothermal conditions in water and brine solutions. The Soxhlet leach test, using radioactive cesium as a tracer, showed that leaching of cermet was about X100 less than that of 78 to 68 glass. Using essentially uncooled, untreated waste, cermet fixation was found to accommodate up to 75% waste loading and yet, because of its high thermal conductivity, a monolith of 0.6 m diameter and 3.3 m-length would have only a maximum centerline temperature of 29 K above the ambient value

  19. N2 Fixation by Grain Legume Varieties as Affected By Rhizobia ...

    African Journals Online (AJOL)

    acer

    [*Author of Correspondence: hyakubu2009@g-mail.com]. 229. ABSTRACT: ... Yusuf et al, (2006) reported that cowpea fixed. 16-34kgN/ha and ... fixation of legume crops (Michiels et al.,. 1994). ..... Robert, M.B. (1995). ... nitrogen fixation), John.

  20. Quantitative analysis of an engineered CO2-fixing Escherichia coli reveals great potential of heterotrophic CO2 fixation.

    Science.gov (United States)

    Gong, Fuyu; Liu, Guoxia; Zhai, Xiaoyun; Zhou, Jie; Cai, Zhen; Li, Yin

    2015-01-01

    Production of fuels from the abundant and wasteful CO2 is a promising approach to reduce carbon emission and consumption of fossil fuels. Autotrophic microbes naturally assimilate CO2 using energy from light, hydrogen, and/or sulfur. However, their slow growth rates call for investigation of the possibility of heterotrophic CO2 fixation. Although preliminary research has suggested that CO2 fixation in heterotrophic microbes is feasible after incorporation of a CO2-fixing bypass into the central carbon metabolic pathway, it remains unclear how much and how efficient that CO2 can be fixed by a heterotrophic microbe. A simple metabolic flux index was developed to indicate the relative strength of the CO2-fixation flux. When two sequential enzymes of the cyanobacterial Calvin cycle were incorporated into an E. coli strain, the flux of the CO2-fixing bypass pathway accounts for 13 % of that of the central carbon metabolic pathway. The value was increased to 17 % when the carbonic anhydrase involved in the cyanobacterial carbon concentrating mechanism was introduced, indicating that low intracellular CO2 concentration is one limiting factor for CO2 fixation in E. coli. The engineered CO2-fixing E. coli with carbonic anhydrase was able to fix CO2 at a rate of 19.6 mg CO2 L(-1) h(-1) or the specific rate of 22.5 mg CO2 g DCW(-1) h(-1). This CO2-fixation rate is comparable with the reported rates of 14 autotrophic cyanobacteria and algae (10.5-147.0 mg CO2 L(-1) h(-1) or the specific rates of 3.5-23.7 mg CO2 g DCW(-1) h(-1)). The ability of CO2 fixation was created and improved in E. coli by incorporating partial cyanobacterial Calvin cycle and carbon concentrating mechanism, respectively. Quantitative analysis revealed that the CO2-fixation rate of this strain is comparable with that of the autotrophic cyanobacteria and algae, demonstrating great potential of heterotrophic CO2 fixation.

  1. Relation between lowered colloid osmotic pressure, respiratory failure, and death.

    Science.gov (United States)

    Tonnesen, A S; Gabel, J C; McLeavey, C A

    1977-01-01

    Plasma colloid osmotic pressure was measured each day in 84 intensive care unit patients. Probit analysis demonstrated a direct relationship between colloid osmotic pressure (COP) and survival. The COP associated with a 50% survival rate was 15.0 torr. COP was higher in survivors than in nonsurvivors without respiratory failure and in patients who recovered from respiratory failure. We conclude that lowered COP is associated with an elevated mortality rate. However, the relationship to death is not explained by the relationship to respiratory failure.

  2. Capture of fixation by rotational flow; a deterministic hypothesis regarding scaling and stochasticity in fixational eye movements

    Directory of Open Access Journals (Sweden)

    Nicholas Mansel Wilkinson

    2014-02-01

    Full Text Available Visual scan paths exhibit complex, stochastic dynamics. Even during visual fixation, the eye is in constant motion. Fixational drift and tremor are thought to reflect fluctuations in the persistent neural activity of neural integrators in the oculomotor brainstem, which integrate sequences of transient saccadic velocity signals into a short term memory of eye position. Despite intensive research and much progress, the precise mechanisms by which oculomotor posture is maintained remain elusive. Drift exhibits a stochastic statistical profile which has been modelled using random walk formalisms. Tremor is widely dismissed as noise. Here we focus on the dynamical profile of fixational tremor, and argue that tremor may be a signal which usefully reflects the workings of the oculomotor postural control. We identify signatures reminiscent of a certain flavour of transient neurodynamics; toric travelling waves which rotate around a central phase singularity. Spiral waves play an organisational role in dynamical systems at many scales throughout nature, though their potential functional role in brain activity remains a matter of educated speculation. Spiral waves have a repertoire of functionally interesting dynamical properties, including persistence, which suggest that they could in theory contribute to persistent neural activity in the oculomotor postural control system. Whilst speculative, the singularity hypothesis of oculomotor postural control implies testable predictions, and could provide the beginnings of an integrated dynamical framework for eye movements across scales.

  3. Contributions of retinal input and phenomenal representation of a fixation object to the saccadic gap effect.

    Science.gov (United States)

    Ueda, Hiroshi; Takahashi, Kohske; Watanabe, Katsumi

    2013-04-19

    The saccadic "gap effect" refers to a phenomenon whereby saccadic reaction times (SRTs) are shortened by the removal of a visual fixation stimulus prior to target presentation. In the current study, we investigated whether the gap effect was influenced by retinal input of a fixation stimulus, as well as phenomenal permanence and/or expectation of the re-emergence of a fixation stimulus. In Experiment 1, we used an occluded fixation stimulus that was gradually hidden by a moving plate prior to the target presentation, which produced the impression that the fixation stimulus still remained and would reappear from behind the plate. We found that the gap effect was significantly weakened with the occluded fixation stimulus. However, the SRT with the occluded fixation stimulus was still shorter in comparison to when the fixation stimulus physically remained on the screen. In Experiment 2, we investigated whether this effect was due to phenomenal maintenance or expectation of the reappearance of the fixation stimulus; this was achieved by using occluding plates that were an identical color to the background screen, giving the impression of reappearance of the fixation stimulus but not of its maintenance. The result showed that the gap effect was still weakened by the same degree even without phenomenal maintenance of the fixation stimulus. These results suggest that the saccadic gap effect is modulated by both retinal input and subjective expectation of re-emergence of the fixation stimulus. In addition to oculomotor mechanisms, other components, such as attentional mechanisms, likely contribute to facilitation of the subsequent action. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Non-metallic implant for patellar fracture fixation: A systematic review.

    Science.gov (United States)

    Camarda, Lawrence; Morello, Salvatore; Balistreri, Francesco; D'Arienzo, Antonio; D'Arienzo, Michele

    2016-08-01

    Despite good clinical outcome proposals, there has been relatively little published regarding the use of non-metallic implant for patellar fracture fixation. The purpose of the study was to perform a systematic literature review to summarize and evaluate the clinical studies that described techniques for treating patella fractures using non-metallic implants. A comprehensive literature search was systematically performed to evaluate all studies included in the literature until November 2015. The following search terms were used: patellar fracture, patella suture, patella absorbable, patella screw, patella cerclage. Two investigators independently reviewed all abstracts and the selection of these abstracts was then performed based on inclusion and/or exclusion criteria. A total of 9 studies involving 123 patients were included. Patients had a mean age of 33.7 years and were followed up for a mean of 18.9 months. The most common method for fracture fixations included the use of suture material. Good clinical outcomes were reported among all studies. Thirteen patients (10.5%) presented complications, while 4 patients (3.2%) required additional surgery for implant removal. There is a paucity of literature focused on the use of non-metallic implant for patellar fracture fixation. However, this systematic review showed that non-metallic implants are able to deliver good clinical outcomes reducing the rate of surgical complications and re-operation. These results may assist surgeons in choosing to use alternative material such as sutures to incorporate into their routine practice or to consider it, in order to reduce the rate of re-operation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Accuracy of a hexapod parallel robot kinematics based external fixator.

    Science.gov (United States)

    Faschingbauer, Maximilian; Heuer, Hinrich J D; Seide, Klaus; Wendlandt, Robert; Münch, Matthias; Jürgens, Christian; Kirchner, Rainer

    2015-12-01

    Different hexapod-based external fixators are increasingly used to treat bone deformities and fractures. Accuracy has not been measured sufficiently for all models. An infrared tracking system was applied to measure positioning maneuvers with a motorized Precision Hexapod® fixator, detecting three-dimensional positions of reflective balls mounted in an L-arrangement on the fixator, simulating bone directions. By omitting one dimension of the coordinates, projections were simulated as if measured on standard radiographs. Accuracy was calculated as the absolute difference between targeted and measured positioning values. In 149 positioning maneuvers, the median values for positioning accuracy of translations and rotations (torsions/angulations) were below 0.3 mm and 0.2° with quartiles ranging from -0.5 mm to 0.5 mm and -1.0° to 0.9°, respectively. The experimental setup was found to be precise and reliable. It can be applied to compare different hexapod-based fixators. Accuracy of the investigated hexapod system was high. Copyright © 2014 John Wiley & Sons, Ltd.

  6. [Subluxation of scleral-fixated PC IOL caused by polypropylene suture degradation--case report].

    Science.gov (United States)

    Kanigowska, Krystyna; Grałek, Mirosława; Czarnowska, Elzbieta; Zajaczkowska, Agnieszka

    2009-01-01

    The purpose of the study is to evaluate factors related to late-onset of lens subluxation in transscleral sutured posterior chamber IOL. We report a child, which required surgical treatment for dislocation of a scleral-sutured PC IOL. 11 years earlier the secondary lens implantation with scleral fixation was performed in 4 years old boy. The first surgical procedure included an anterior victrectomy and suturing a single- piece PMMA IOL under the scleral flaps with a 10-0 polipropylene suture. The second--included explantation of the dislocated lens. Optic and scanning electron microscopy was used to analyze the surface of the explanted remnants of the breakage suture. Microscopic findings indicate that the late suture breakage and subluxation of suture-fixated PC IOL was due to the degradation of polypropylene suture.

  7. Single absorbable polydioxanone pin fixation for distal chevron bunion osteotomies.

    Science.gov (United States)

    Deorio, J K; Ware, A W

    2001-10-01

    The distal chevron osteotomy is a well-established technique for correction of symptomatic mild to moderate metatarsus primus varus with hallux valgus deformity. Fixation of the osteotomy ranges from none to bone pegs, Kirschner wires, screws, or absorbable pins. We evaluated one surgeon's (J.K.D.) results of distal chevron osteotomy fixation with a single, nonpredrilled, 1.3-mm poly-p-dioxanone pin and analyzed any differences in patients with unilateral or bilateral symptomatic metatarsus primus varus with hallux valgus deformities. All osteotomies healed without evidence of infection, osteolysis, nonunion, or necrosis. Equal correction was achieved in unilateral and bilateral procedures. The technique is quick and easy, and adequate fixation is achieved.

  8. Sulfur Fixation by Chemically Modified Red Mud Samples Containing Inorganic Additives: A Parametric Study

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2016-01-01

    Full Text Available Sulfur retention ability of Bayer red mud from alumina plant was investigated. Bayer red mud modified by fusel salt and waste mother liquor of sodium ferrocyanide as the main sulfur fixation agent and the calcium based natural mineral materials as servicing additives; the experimental results showed the following: (1 Through 10 wt% waste mother liquor of sodium ferrocyanide modifying Bayer red mud, sulfur fixation rate can increase by 13 wt%. (2 Magnesium oxide can obviously improve the sulfur fixation performance of Bayer red mud and up to a maximum sulfur fixation rate of 47 wt% at adding 1 wt% magnesium oxide. (3 Dolomite enhanced the sulfur fixation performances with the sulfur fixation rate of 68 wt% in optimized condition. (4 Vermiculite dust reduced sulfur dioxide during the fixed-sulfur process of modified Bayer red mud, and the desulphurization ration could reach up to a maximum 76 wt% at 950°C. (5 An advanced three-component sulfur fixation agent was investigated, in which the optimized mass ratio of modified Bayer red mud, dolomite, and vermiculite dust was 70 : 28 : 2 in order, and its sulfur fixation efficiency has reached to a maximum 87 wt% under its 20 wt% dosage in the coal.

  9. Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique.

    Science.gov (United States)

    Yamane, Shin; Sato, Shimpei; Maruyama-Inoue, Maiko; Kadonosono, Kazuaki

    2017-08-01

    To report the clinical outcomes of a new technique for transconjunctival intrascleral fixation of an intraocular lens (IOL). Prospective, noncomparative, interventional case series. One hundred eyes of 97 consecutive patients with aphakia, dislocated IOL, or subluxated crystalline lens who underwent posterior chamber sutureless implantation of an IOL were studied. Two angled incisions parallel to the limbus were made by 30-gauge thin-wall needles. Haptics of an IOL were externalized with the needles and cauterized to make a flange of the haptics. The flange of the haptics were pushed back and fixed into the scleral tunnels. Best-corrected visual acuity (VA), corneal endothelial cell density, IOL tilt, and complications were determined. The IOLs were fixed with exact centration and axial stability. The mean preoperative best-corrected VA was 0.25 logarithm of the minimum angle of resolution (logMAR) units; after surgery, it improved significantly to 0.11 logMAR, 0.09 logMAR, 0.12 logMAR, and 0.04 logMAR at 6, 12, 24, and 36 months, respectively (P IOL tilt was 3.4°±2.5°. The postoperative complications included iris capture by the IOL in 8 eyes (8%), vitreous hemorrhage in 5 eyes (5%), and cystoid macular edema in 1 eye (1%). There were no incidents of postoperative retinal detachment, endophthalmitis, or IOL dislocation. We have developed a new technique for intrascleral IOL fixation. The flanged IOL fixation technique is a simple and minimally invasive method for achieving good IOL fixation with firm haptic fixation. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Operative fixation of chest wall fractures: an underused procedure?

    Science.gov (United States)

    Richardson, J David; Franklin, Glen A; Heffley, Susan; Seligson, David

    2007-06-01

    Chest wall fractures, including injuries to the ribs and sternum, usually heal spontaneously without specific treatment. However, a small subset of patients have fractures that produce overlying bone fragments that may produce severe pain, respiratory compromise, and, if untreated mechanically, result in nonunion. We performed open reduction and internal fixation on seven patients with multiple rib fractures-five in the initial hospitalization and two delayed--as well as 35 sternal fractures (19 immediate fixation and 16 delayed). Operative fixation was accomplished using titanium plates and screws in both groups of patients. All patients with rib fractures did well; there were no major complications or infections, and no plates required removal. Clinical results were excellent. There was one death in the sternal fracture group in a patient who was ventilator-dependent preoperatively and extubated himself in the early postoperative period. Otherwise, the results were excellent, with no complications occurring in this group. Three patients had their plates removed after boney union was achieved. No evidence of infection or nonunion occurred. The excellent results achieved in the subset of patients with severe chest wall deformities treated initially at our institution and those referred from outside suggest that operative fixation is a useful modality that is likely underused.

  11. Intraocular lens iris fixation. Clinical and macular OCT outcomes

    Science.gov (United States)

    2012-01-01

    Background To assess the efficacy, clinical outcomes, visual acuity (VA), incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany) were analyzed. Findings The final CDVA was 20/40 or better in 8 eyes (62%), 20/60 or better in 12 eyes (92%), and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT. Conclusions We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method. PMID:23050659

  12. Fixation probability of a nonmutator in a large population of asexual mutators.

    Science.gov (United States)

    Jain, Kavita; James, Ananthu

    2017-11-21

    In an adapted population of mutators in which most mutations are deleterious, a nonmutator that lowers the mutation rate is under indirect selection and can sweep to fixation. Using a multitype branching process, we calculate the fixation probability of a rare nonmutator in a large population of asexual mutators. We show that when beneficial mutations are absent, the fixation probability is a nonmonotonic function of the mutation rate of the mutator: it first increases sublinearly and then decreases exponentially. We also find that beneficial mutations can enhance the fixation probability of a nonmutator. Our analysis is relevant to an understanding of recent experiments in which a reduction in the mutation rates has been observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Nitrogen Fixation in the Intertidal Sediments of the Yangtze Estuary: Occurrence and Environmental Implications

    Science.gov (United States)

    Hou, Lijun; Wang, Rong; Yin, Guoyu; Liu, Min; Zheng, Yanling

    2018-03-01

    Nitrogen fixation is a microbial-mediated process converting atmospheric dinitrogen gas to biologically available ammonia or other molecules, and it plays an important role in regulating nitrogen budgets in coastal marine ecosystems. In this study, nitrogen fixation in the intertidal sediments of the Yangtze Estuary was investigated using nitrogen isotope tracing technique. The abundance of nitrogen fixation functional gene (nifH) was also quantified. The measured rates of sediment nitrogen fixation ranged from 0.37 to 7.91 nmol N g-1 hr-1, while the abundance of nifH gene varied from 2.28 × 106 to 1.28 × 108 copies g-1 in the study area. The benthic nitrogen fixation was correlated closely to the abundance of nifH gene and was affected significantly by salinity, pH, and availability of sediment organic carbon and ammonium. It is estimated that sediment nitrogen fixation contributed approximately 9.3% of the total terrigenous inorganic nitrogen transported annually into the Yangtze estuarine and coastal environment. This result implies that the occurrence of benthic nitrogen fixation acts as an important internal source of reactive nitrogen and to some extent exacerbates nitrogen pollution in this aquatic ecosystem.

  14. Operative Fixation of Rib Fractures Indications, Techniques, and Outcomes.

    Science.gov (United States)

    Galos, David; Taylor, Benjamin; McLaurin, Toni

    2017-01-01

    Rib fractures are extremely common injuries and vary in there severity from single nondisplaced fractures to multiple segmental fractures resulting in flail chest and respiratory compromise. Historically, rib fractures have been treated conservatively with pain control and respiratory therapy. However this method may not be the best treatment modality in all situations. Operative fixation of select rib fractures has been increasing in popularity especially in patients with flail chest and respiratory compromise. Newer techniques use muscle sparing approaches and precontoured locking plate technology to obtain stable fixation and allow improved respiration. Current reports shows that rib fracture fixation offers the benefits of improved respiratory mechanics and improved pain control in the severe chest wall injury with resultant improvement in patient outcomes by decreasing time on the ventilator, time in the intensive care unit, and overall hospital length of stay.

  15. Biomechanical Analysis of Suture Anchor vs Tenodesis Screw for FHL Transfer.

    Science.gov (United States)

    Drakos, Mark C; Gott, Michael; Karnovsky, Sydney C; Murphy, Conor I; DeSandis, Bridget A; Chinitz, Noah; Grande, Daniel; Chahine, Nadeen

    2017-07-01

    Chronic Achilles injury is often treated with flexor hallucis longus (FHL) tendon transfer to the calcaneus using 1 or 2 incisions. A single incision avoids the risks of extended dissections yet yields smaller grafts, which may limit fixation options. We investigated the required length of FHL autograft and biomechanical profiles for suture anchor and biotenodesis screw fixation. Single-incision FHL transfer with suture anchor or biotenodesis screw fixation to the calcaneus was performed on 20 fresh cadaveric specimens. Specimens were cyclically loaded until maximal load to failure. Length of FHL tendon harvest, ultimate load, stiffness, and mode of failure were recorded. Tendon harvest length needed for suture anchor fixation was 16.8 ± 2.1 mm vs 29.6 ± 2.4 mm for biotenodesis screw ( P = .002). Ultimate load to failure was not significantly different between groups. A significant inverse correlation existed between failure load and donor age when all specimens were pooled (ρ = -0.49, P Anchor failure occurred mostly by suture breakage (n = 8). Adequate FHL tendon length could be harvested through a single posterior incision for fixation to the calcaneus with either fixation option, but suture anchor required significantly less graft length. Stiffness, fixation strength, and load to failure were comparable between groups. An inverse correlation existed between failure load and donor age. Younger specimens with screw fixation demonstrated significantly greater failure loads. Adequate harvest length for FHL transfer could be achieved with a single posterior incision. There was no difference in strength of fixation between suture anchor and biotenodesis screw.

  16. Outcome of 28 open pilon fractures with injury severity-based fixation.

    Science.gov (United States)

    Danoff, Jonathan R; Saifi, Comron; Goodspeed, David C; Reid, J Spence

    2015-04-01

    Open pilon fracture management and treatment poses a significant challenge to orthopedic surgeons. The purpose of this study was to determine patient outcomes for open pilon fractures based on wound complication and infection rates, as well as subjective outcome instruments. This was a retrospective consecutive case series of 28 fractures with Orthopaedic Trauma Association (OTA)-type 43-B and 43-C open pilon fractures. Mean length of follow-up was 36 months and minimum of 1 year. Ten fractures were Gustilo and Anderson grade IIIB, and the remaining fractures were grades I-IIIA. Patients were initially treated with spanning external fixation and staged wound debridement followed by osteosynthesis of the articular surface. Metaphyseal fixation was by either plate fixation or Ilizarov frame. The primary outcome was the incidence of deep tissue infection requiring surgery. Secondary outcomes included the incidence of other complications (nonunion, malunion, amputation) and functional outcomes (Short Musculoskeletal Functional Assessment Questionnaire and AAOS Foot and Ankle Questionnaire). Four patients developed deep tissue infections, three in the internal fixation group and one in the Ilizarov group, and all were treated successfully with staged debridement. There were two delayed unions required bone grafting, and infection-free union was ultimately achieved in all fractures. Two patients underwent arthrodesis secondary to post-traumatic arthritis, while no patients experienced malunions or amputations. The use of staged wound debridement in conjunction with either plate fixation or Ilizarov frame achieves low rates of wound infection and stable fixation after anatomic joint reconstruction for OTA-type 43-B and 43-C open pilon fractures.

  17. Ethanol-Glycerin Fixation with Thymol Conservation: A Potential Alternative to Formaldehyde and Phenol Embalming

    Science.gov (United States)

    Hammer, Niels; Loffler, Sabine; Feja, Christine; Sandrock, Mara; Schmidt, Wolfgang; Bechmann, Ingo; Steinke, Hanno

    2012-01-01

    Anatomical fixation and conservation are required to prevent specimens from undergoing autolysis and decomposition. While fixation is the primary arrest of the structures responsible for autolysis and decomposition, conservation preserves the state of fixation. Although commonly used, formaldehyde has been classified as carcinogenic to humans. For…

  18. Analysis of unavailability related to demand failures as a function of the testing interval

    International Nuclear Information System (INIS)

    Carretero, J.A.; Pereira, M.B.; Perez Lobo, E.M.

    1998-01-01

    The unavailability related to the demand failure of a component is the sum of the contributions of the failures in demand and in waiting. An important point in PSAs is the calculation of unavailabilities of the basic events of demand failure. Several criteria are used for this, with the objective of simplifying said quantification. The information available from two nuclear power plants has been analysed, in order to determine the tendency in the models in demand and in waiting, as a function of the test intervals, the following conclusions were obtained: - There is a clear tendency for the possibility of failure in demand to increase as the interval between tests increases - The test intervals considered in PSAs are not always coherent with the estimates of real demand; this implies a penalty when using the in waiting model, due to the underlying conservatism Therefore, increasing the intervals between tests over time (a tendency studied in nuclear power plants)could cause demand due to tests to b e significantly less than that due to real actuations. This implies a need to apply test intervals based on historic demands and not on those due to historic tests, in order to avoid conservatism. (Author)

  19. Effects of SO/sub 2/ on photosynthesis and nitrogen fixation

    Energy Technology Data Exchange (ETDEWEB)

    Haellgren, J E; Huss, K

    1975-06-15

    Responses of photosynthesis and nitrogen fixation to NaHSO/sub 3/ (10/sup -5/ to 5 x 10/sup -3/ M) were investigated in the lichen Stereocaulon paschale (L.) Fr. and the blue-green alga Anabaena cylindrica Lemmermann. The treatments were performed in buffered media with varying pH (5.8 to 8.1) and light conditions (0 to 32 W x m/sup -2/). The activities of the intact organisms were investigated, under the same environmental conditions, with /sup 14/C liquid scintillation and acetylene reduction techniques respectively. The nitrogen fixation proved to be more susceptible than photosynthesis, in both organisms, and in all cases treatments at pH 5.8 were more inhibitory than at higher pH-values. Treatment with 5 x 10/sup -4/ M NaHSO/sub 3/ at pH 5.8 caused no reduction of photosynthesis in S. paschale, while the inhibition of nitrogen fixation was 97%. For A. cylindrica the corresponding values were 40% and 75% respectively. Short-time treatments of A. cylindrica showed that the nitrogen fixation was more rapidly affected than photosynthesis. The inhibition of nitrogenase activity and CO/sub 2/-fixation was smaller in the dark and increased at higher light intensities. Both processes showed a good capacity for recovery after removal of the NaHSO/sub 3/ solution. Also the clumping ability of A. cylindrica was disturbed by NaHSO/sub 3/ treatments.

  20. [Staple fixation for the treatment of hamate metacarpal joint injury].

    Science.gov (United States)

    Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da

    2014-03-01

    To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.

  1. Calculation of the time fixation accuracy for Si(Li)-detectors

    International Nuclear Information System (INIS)

    Kondrat'ev, V.P.; Krasnov, L.V.

    1981-01-01

    An accuracy of time fixation to pulses of changing shape for li-frifted si detectors with thickness over 1 mm is evaluated. The method of the comparison of main and converted signal shapes is the most universal method of time fixation. The idea of the method consists in shaping a bipolar pulse using a single-polar input Rulse and recording the point of the bipolar signal intersection with the zero level. The combination of an analytical method with numerical computer calculations is used for evaluating the time fixation fluctuations. Analysis of the results obtained shows that the value of delay p=tausub(d)/tausub(n) (where tausub(d) is delay time for the main part of a signal, tausub(n) is the maximum time of electron collection) affects most strongly the time shift. The parameter K=tausub(i)/tausub(n) (tausub(i) is a constant of integrating circuit) affects slightly the maximum value of time shift. For the li-drifted si detector 2 mm thick with dispattacement vottage of 400 V the moment of the time fixation will be equal to 47 is in the case of K--1, p=0.4 and x=0.25 (x=R/i, where R is a particle range in the detector, l is the thickness of the detector depleted area. The fluctuations in time fixation don't exceed 2.3 ns for the whole particle energy range

  2. Ultrastructure of the endolymphatic duct in the rat. Fixation and preservation

    DEFF Research Database (Denmark)

    Qvortrup, K; Rostgaard, J

    1993-01-01

    Ten rats were vascular-perfused at subphysiologic as well as physiologic pressures, 80 mmHg and 120 mmHg, respectively, employing a pressure feed-back controlled peristaltic pump and an isotonic perfusate/fixative with colloids (2% Dextran) and a hypertonic perfusate/fixative without colloids, 300...

  3. Stent migration following endoscopic suture fixation of esophageal self-expandable metal stents: a systematic review and meta-analysis.

    Science.gov (United States)

    Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth

    2018-02-01

    Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2  = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2  = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.

  4. DISTRACTION EXTERNAL FIXATIONS OF PELVIC FRACTURES CAUSED BY A LATERAL COMPRESSION.

    Directory of Open Access Journals (Sweden)

    Pavlin Apostolov

    2011-11-01

    Full Text Available The authors represent a distraction external pelvic fixation technique, which they use in pelvic fractures caused by a lateral compression. They consider the indications and mounting techniques. The authors recommend the early movement activities (on the 3rd - 5th day after the external fixator placement. This method had been used in 8 patients and 3 cases are analyzed in details. The priority of this technique over open reduction and internal fixation (ORIF mainly are: (1 the implementation of good reduction of the fracture preventing the risk of ORIF; (2 the possibility for early movement activities for the patient.

  5. Interpretation of Post-operative Distal Humerus Radiographs After Internal Fixation: Prediction of Later Loss of Fixation

    NARCIS (Netherlands)

    Claessen, F.M.; Stoop, N.; Doornberg, J.N.; Guitton, T.G.; Bekerom, M.P. van den; Ring, D.; Biert, J.; et al.,

    2016-01-01

    PURPOSE: Stable fixation of distal humerus fracture fragments is necessary for adequate healing and maintenance of reduction. The purpose of this study was to measure the reliability and accuracy of interpretation of postoperative radiographs to predict which implants will loosen or break after

  6. Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures.

    Science.gov (United States)

    Lei, Jianyin; Dong, Pengfei; Li, Zhiqiang; Zhu, Feng; Wang, Zhihua; Cai, Xianhua

    2017-05-01

    The aim of this study was to evaluate the biomechanical properties of common fixation systems for complex acetabular fractures. A finite element (FE) pelvic model with anterior column and posterior hemi-transverse acetabular fractures was created. Three common fixation systems were used to fix the posterior wall acetabular fractures: 1. Anterior column plate combined with posterior column screws (group I), 2. Anterior column plate combined with quadrilateral area screws (group II) and 3. Double-column plates (group III). And 600 N, representing the body weight, was loaded on the upper surface of the sacrum to simulate the double-limb stance. The amounts of total and relative displacements were compared between the groups. The total amount of displacement was 2.76 mm in group II, 2.81 mm in group III, and 2.83 mm in group I. The amount of relative displacement was 0.0078 mm in group II, 0.0093 mm in group III and 0.014 mm in group I. Our results suggested that all fixation systems enhance biomechanical stability significantly. Anterior column plate combined with quadrilateral area screws has quite comparable results to double column plates, they were superior to anterior column plate combined with posterior screws. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  7. [Automated analysis of bacterial preparations manufactured on automatic heat fixation and staining equipment].

    Science.gov (United States)

    2012-01-01

    Heat fixation of preparations was made in the fixation bath designed by EMKO (Russia). Programmable "Emkosteiner" (EMKO, Russia) was used for trial staining. Reagents set Micko-GRAM-NITsF was applied for Gram's method of staining. It was demostrated that automatic smear fixation equipment and programmable staining ensure high-quality imaging (1% chromaticity variation) good enough for standardization of Gram's staining of microbial preparations.

  8. Factors related to outcome in heart failure with a preserved (or normal) left ventricular ejection fraction.

    Science.gov (United States)

    Sanderson, John E

    2016-07-01

    Heart failure with a preserved ejection faction (HFpEF) is a growing and expensive cause of heart failure (HF) affecting particularly the elderly. It differs in substantial ways in addition to the normal left ventricular ejection fraction, from the more easily recognized form of heart failure with a reduced ejection fraction (HFrEF or 'systolic heart failure') and unlike HFrEF there have been little advances in treatment. In part, this relates to the complexity of the pathophysiology and identifying the correct targets. In HFpEF, there appears to be widespread stiffening of the vasculature and the myocardium affecting ventricular function (both systolic and diastolic), impeding ventricular suction, and thus early diastolic filling leading to breathlessness on exertion and later atrial failure and fibrillation. Left ventricular ejection fraction tends to gradually decline and some evolve into HFrEF. Most patients also have a mixture of several co-morbidities including hypertension, diabetes, obesity, poor renal function, lack of fitness, and often poor social conditions. Therefore, many factors may influence outcome in an individual patient. In this review, the epidemiology, possible causation, pathophysiology, the influence of co-morbidities and some of the many potential predictors of outcome will be considered.

  9. Brain rhythms alterations and their effect in functional networks: A simultaneous EEG/fMRI study in Fixation-off epilepsy

    OpenAIRE

    Solana Sánchez, Ana Beatriz; Hernández Tamames, J.A.; Molina, Elena; Martínez, Kenia; Alcalá, Juan José; Toledano, Rafael; San Antonio-Arce, Victoria; Garcia Morales, Irene; Gil Nagel, Antonio; Maestu Unturbe, Ceferino; Alvarez Linera, Juan; Alfayate, E.; Pozo Guerrero, Francisco del

    2012-01-01

    Fixation-off sensitivity (FOS) denotes the forms of EEG abnormalities, which are elicited by elimination of central vision or fixation. The phenomenon seems to depend on variables that modulate the alpha rhythm, however, the cerebral mechanisms underlying FOS remain unclear [1]. The scarce previous fMRI findings related to FOS have shown activation in extrastriate cortex [2] and also in frontal areas [3][4]. On the other hand, simultaneous EEG-fMRI technique has been used to assess the relati...

  10. Seasonal patterns of periphyton nitrogen fixation in calcareous wetlands

    Science.gov (United States)

    Liao, X.; Inglett, P.

    2011-12-01

    Periphyton mats are an ecologically important component of the Everglades ecosystem and plays various vital ecological functions. However, nitrogen fixation of periphyton, has received little attention throughout much of the Everglades system. The objective of this study was to characterize the seasonal pattern of periphyton N2 fixation in the Hole-in-the-Donut (HID) of Florida Everglades, where farmed marl prairie wetlands have been restored through complete soil removal (CSR) to reduce nutrient levels. Two restored areas (i.e., cleared in 2000 and 2003) and a reference (natural and unfarmed) marl prairie wetland sites were selected in the HID. Seven times of sampling were performed across the wet and dry season during the 2010 and 2011. The annual fixed nitrogen was approximately 0.4gN m-2 yr-1 in the restored sites which was higher in the reference site (~0.2gN m-2 yr-1). All the three sites showed similar seasonal patterns of N2 fixation that is higher values were observed in the wet season; but the peak value was one month later in reference sits (i.e., September) comparing to the restored areas (i.e., July). The peak of periphyton AR rates in the 2000- and 2003-restored areas appeared in July (i.e., wet season) within the range of 20-79 nmols g-1dw h-1 and 31-53nmols g-1dw h-1, respectively. In contrast, the peak of reference site was observed in September with the range of 2-5 nmols g-1dw h-1. Stable N isotopic ratios (i.e., δ15N) also varied with time but didn't show consistent seasonal pattern as nitrogen fixation. N2 fixation positively correlated with periphyton total phosphorus (TP) and negatively correlated with total nitrogen and phosphorus molar ratios (TN:TP), indicating that N2 fixation would be a indicator of nutrient limitation. In general, δ15N was negatively correlated with nitrogenase activity but the correlation became weakened in the wet season, especially in the flooded July and September, which would be explained by other environmental

  11. Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator.

    Science.gov (United States)

    Tafazal, Suhayl; Madan, Sanjeev S; Ali, Farhan; Padman, Manoj; Swift, Simone; Jones, Stanley; Fernandes, James A

    2014-05-01

    The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, time duration in frame, healing time and complications of treatment. The minimum follow-up was 24 months. Ten patients were treated with ICF between 2000 and 2005, while 15 patients have been treated with TSF since 2005. Two of the 10 treated with ICF and 5 of the 15 treated with TSF were open fractures. All patients went on to achieve complete union. Mean duration in the frame was 12.7 weeks for ICF and 14.8 weeks for the TSF group. Two patients in the TSF group had delayed union and required additional procedures including adjustment of fixator and bone grafting. There was one malunion in the TSF group that required osteotomy and reapplication of frame. There were seven and nine pin-site infections in the ICF and TSF groups, respectively, all of which responded to antibiotics. There were no refractures in either group. In an appropriate patient, both types of circular fixator are equally effective but have different characteristics, with TSF allowing for postoperative deformity correction. Of concern are the two cases of delayed union in the TSF group, all in patients with high-energy injuries. We feel another larger study is required to provide further clarity in this matter. Level II-comparative study.

  12. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  13. Rapid maxillary distraction protocol utilizing the halo distraction system and rigid internal fixation.

    Science.gov (United States)

    Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P

    2007-09-01

    To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.

  14. Plasma catalysis for nitrogen fixation reactions

    NARCIS (Netherlands)

    Patil, B.S.; Wang, Q.; Hessel, V.; Lang, J.; Stankiewicz, A.; Stefanidis, G.

    2016-01-01

    The preferences for localized chemicals production and changing scenarios of renewable electricity cost gives a renewed boost to plasma-assisted valuable chemicals production. Especially, plasma-assisted nitrogen fixation for fertilizer production has the potential to largely change the energy

  15. Failure analysis of the fractured wires in sternal perichronal loops.

    Science.gov (United States)

    Chao, Jesús; Voces, Roberto; Peña, Carmen

    2011-10-01

    We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire fracture was un-branched and transgranular and proceeded by a high cycle fatigue process, apparently in the absence of corrosion. However, stress anlysis indicates that the effective stress produced during strong coughing is lower than the yield strength. Our findings suggest that in order to reduce the risk for sternal dehiscence, the diameter of the wire used should be increased. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Influence of age, spatial memory, and ocular fixation on localization of auditory, visual, and bimodal targets by human subjects.

    Science.gov (United States)

    Dobreva, Marina S; O'Neill, William E; Paige, Gary D

    2012-12-01

    A common complaint of the elderly is difficulty identifying and localizing auditory and visual sources, particularly in competing background noise. Spatial errors in the elderly may pose challenges and even threats to self and others during everyday activities, such as localizing sounds in a crowded room or driving in traffic. In this study, we investigated the influence of aging, spatial memory, and ocular fixation on the localization of auditory, visual, and combined auditory-visual (bimodal) targets. Head-restrained young and elderly subjects localized targets in a dark, echo-attenuated room using a manual laser pointer. Localization accuracy and precision (repeatability) were quantified for both ongoing and transient (remembered) targets at response delays up to 10 s. Because eye movements bias auditory spatial perception, localization was assessed under target fixation (eyes free, pointer guided by foveal vision) and central fixation (eyes fixed straight ahead, pointer guided by peripheral vision) conditions. Spatial localization across the frontal field in young adults demonstrated (1) horizontal overshoot and vertical undershoot for ongoing auditory targets under target fixation conditions, but near-ideal horizontal localization with central fixation; (2) accurate and precise localization of ongoing visual targets guided by foveal vision under target fixation that degraded when guided by peripheral vision during central fixation; (3) overestimation in horizontal central space (±10°) of remembered auditory, visual, and bimodal targets with increasing response delay. In comparison with young adults, elderly subjects showed (1) worse precision in most paradigms, especially when localizing with peripheral vision under central fixation; (2) greatly impaired vertical localization of auditory and bimodal targets; (3) increased horizontal overshoot in the central field for remembered visual and bimodal targets across response delays; (4) greater vulnerability to

  17. Complications Using Bioabsorbable Cross-Pin Femoral Fixation: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Saqib Hasan

    2011-01-01

    Full Text Available The use of bioabsorbable cross-pin transcondylar fixation has remained a viable option for femoral fixation in anterior cruciate ligament reconstruction. Although numerous biomechanical studies have demonstrated high fixation strength and minimal slippage with use of this method of fixation, there have been increasing reports of a variety of clinical complications associated with these implants. We reviewed the literature for all complications associated with the Bio-TransFix implant and present a case report of a patient status after ACL reconstruction using Bio-TransFix cross-pin femoral fixation with iliotibial band friction syndrome from a broken cross-pin four month post-operatively.

  18. Design Fixation and Cooperative Learning in Elementary Engineering Design Project: A Case Study

    Directory of Open Access Journals (Sweden)

    Yi Luo

    2015-09-01

    Full Text Available This paper presents a case study examining 3rd, 4th and 5th graders’ design fixation and cooperative learning in an engineering design project. A mixed methods instrument, the Cooperative Learning Observation Protocol (CLOP, was adapted to record frequency and class observation on cooperative learning engagement through detailed field notes. Students’ design journals and reflections were also analyzed for an inductive qualitative analysis. The findings indicate three major themes of design fixation: 1 fixation on common features of things; 2 fixation on popular teenage culture; 3 fixation on the first design idea. In the cooperative learning process of elementary engineering design project, although pupils had demonstrated some abilities to solve concrete problems in a logical fashion, the participants encountered a number of obstacles in the group. Dominance, social loafing, and other problems occurring in the group process might have offset certain benefits of cooperative learning. Implications of the findings are also discussed.

  19. Design fixation and cooperative learning in elementary engineering design project: A case study

    Directory of Open Access Journals (Sweden)

    Yi Luo

    2015-09-01

    Full Text Available This paper presents a case study examining 3rd, 4th and 5th graders’ design fixation and cooperative learning in an engineering design project. A mixed methods instrument, the Cooperative Learning Observation Protocol (CLOP, was adapted to record frequency and class observation on cooperative learning engagement through detailed field notes. Students’ design journals and reflections were also analyzed for an inductive qualitative analysis. The findings indicate three major themes of design fixation: 1 fixation on common features of things; 2 fixation on popular teenage culture; 3 fixation on the first design idea. In the cooperative learning process of elementary engineering design project, although pupils had demonstrated some abilities to solve concrete problems in a logical fashion, the participants encountered a number of obstacles in the group. Dominance, social loafing, and other problems occurring in the group process might have offset certain benefits of cooperative learning. Implications of the findings are also discussed.

  20. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis.

    Science.gov (United States)

    Zhao, Y; Zhang, S; Sun, T; Wang, D; Lian, W; Tan, J; Zou, D; Zhao, Y

    2013-09-01

    To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications. A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared. The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1. In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended