WorldWideScience

Sample records for relap4 computer code

  1. Relap4/SAS/Mod5 - A version of Relap4/Mod 5 adapted to IPEN/CNEN - SP computer center

    International Nuclear Information System (INIS)

    Sabundjian, G.

    1988-04-01

    In order to improve the safety of nuclear reactor power plants several computer codes have been developed in the area of thermal - hydraulics accident analysis. Among the public-available codes, RELAP4, developed by Aerojet Nuclear Company, has been the most popular one. RELAP4 has produced satisfactory results when compared to most of the available experimental data. The purposes of the present work are: optimization of RELAP4 output and messages by writing there information in temporary records, - display of RELAP4 results in graphical form through the printer. The sample problem consists on a simplified model of a 150 MW (e) PWR whose primary circuit is simulated by 6 volumes, 8 junctions and 1 heat slab. This new version of RELAP4 (named RELAP4/SAS/MOD5) have produced results which show that the above mentioned purposes have been reached. Obviously the graphical output by RELAP4/SAS/MOD5 favors the interpretation of results by the user. (author) [pt

  2. Evaluation of the RELAP4/MOD6 thermal-hydraulic code

    International Nuclear Information System (INIS)

    Haigh, W.S.; Margolis, S.G.; Rice, R.E.

    1978-01-01

    The NRC RELAP4/MOD6 computer code was recently released to the public for use in thermal-hydraulic analysis. This code has a unique new capability permitting analysis of both the blowdown and reflood portions of a postulated pressurized water reactor (PWR) loss-of-coolant accident (LOCA). A principal code evaluation objective is to assess the accuracy of the code for computing LOCA behavior over a wide range of system sizes and scaling concepts. The scales of interest include all LOCA experiments and will ultimately encompass full-sized PWR systems for which no experiments or data are available. Quantitative assessment of the accuracy of the code when it is applied to large PWR systems is still in the future. With RELAP4/MOD6, however, a technique has been demonstrated for using results derived from small-scale blowdown and reflood experiments to predict the accuracy of calculations for similar experiments of significantly different scale or component size. This demonstration is considered a first step in establishing confidence levels for the accuracy of calculations of a postulated LOCA

  3. Code development and analysis program. RELAP4/MOD7 (Version 2): user's manual

    International Nuclear Information System (INIS)

    1978-08-01

    This manual describes RELAP4/MOD7 (Version 2), which is the latest version of the RELAP4 LPWR blowdown code. Version 2 is a precursor to the final version of RELAP4/MOD7, which will address LPWR LOCA analysis in integral fashion (i.e., blowdown, refill, and reflood in continuous fashion). This manual describes the new code models and provides application information required to utilize the code. It must be used in conjunction with the RELAP4/MOD5 User's Manual (ANCR-NUREG-1335, dated September 1976), and the RELAP4/MOD6 User's Manual

  4. Preliminary validation of RELAP5/Mod4.0 code for LBE cooled NACIE facility

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, Indu; Khanna, Ashok, E-mail: akhanna@iitk.ac.in

    2017-04-01

    Highlights: • Detail discussion of thermo physical properties of Lead Bismuth Eutectic incorporated in the code RELAP5/Mod4.0 included. • Benchmarking of LBE properties in RELAP5/Mod4.0 against literature. • NACIE facility for three different power levels (10.8, 21.7 and 32.5 kW) under natural circulation considered for benchmarking. • Preliminary validation of the LBE properties against experimental data. • NACIE facility for power level 22.5 kW considered for validation. - Abstract: The one-dimensional thermal hydraulic computer code RELAP5 was developed for thermal hydraulic study of light water reactor as well as for nuclear research reactors. The purpose of this work is to evaluate the code RELAP5/Mod4.0 for analysis of research reactors. This paper consists of three major sections. The first section presents detailed discussions on thermo-physical properties of Lead Bismuth Eutectic (LBE) incorporated in RELAP5/Mod4.0 code. In the second section, benchmarking of RELAP5/Mod4.0 has been done with the Natural Circulation Experimental (NACIE) facility in comparison with Barone’s simulations using RELAP5/Mod3.3. Three different power levels (10.8 kW, 21.7 kW and 32.5 kW) under natural circulation conditions are considered. Results obtained for LBE temperatures, temperature difference across heat section, pin surface temperatures, mass flow rates and heat transfer coefficients in heat section heat exchanger are in agreement with Barone’s simulation results within 7% of average relative error. Third section presents validation of RELAP5/Mod4.0 against the experimental data of NACIE facility performed by Tarantino et al. test number 21 at power of 22.5 kW comparing the profiles of temperatures, mass flow rate and velocity of LBE. Simulation and experimental results agree within 7% of average relative error.

  5. RELAP5/MOD2 code assessment

    International Nuclear Information System (INIS)

    Nithianandan, C.K.; Shah, N.H.; Schomaker, R.J.; Miller, F.R.

    1985-01-01

    Babcock and Wilcox (B and W) has been working with the code developers at EG and G and the US Nuclear Regulatory Commission in assessing the RELAP5/MOD2 computer code for the past year by simulating selected separate-effects tests. The purpose of this assessment has been to evaluate the code for use in MIST (Ref. 2) and OTIS integral system tests simulations and in the prediction of pressurized water reactor transients. B and W evaluated various versions of the code and made recommendations to improve code performance. As a result, the currently released version (cycle 36.1) has been improved considerably over earlier versions. However, further refinements to some of the constitutive models may still be needed to further improve the predictive capability of RELAP5/MOD2. The following versions of the code were evaluated. (1) RELAP/MOD2/Cycle 22 - first released version; (2) YELAP5/Cycle 32 - EG and G test version of RELAP5/MOD2/Cycle 32; (3) RELAP5/MOD2/Cycle 36 - frozen cycle for international code assessment; (4) updates to cycle 36 based on recommendations developed by B and W during the simulation of a Massachusetts Institute of Technology (MIT) pressurizer test; and (5) cycle 36.1 updates received from EG and G

  6. RELAP5/MOD2 code assessment

    Energy Technology Data Exchange (ETDEWEB)

    Nithianandan, C.K.; Shah, N.H.; Schomaker, R.J.; Miller, F.R.

    1985-11-01

    Babcock and Wilcox (B and W) has been working with the code developers at EG and G and the US Nuclear Regulatory Commission in assessing the RELAP5/MOD2 computer code for the past year by simulating selected separate-effects tests. The purpose of this assessment has been to evaluate the code for use in MIST (Ref. 2) and OTIS integral system tests simulations and in the prediction of pressurized water reactor transients. B and W evaluated various versions of the code and made recommendations to improve code performance. As a result, the currently released version (cycle 36.1) has been improved considerably over earlier versions. However, further refinements to some of the constitutive models may still be needed to further improve the predictive capability of RELAP5/MOD2. The following versions of the code were evaluated. (1) RELAP/MOD2/Cycle 22 - first released version; (2) YELAP5/Cycle 32 - EG and G test version of RELAP5/MOD2/Cycle 32; (3) RELAP5/MOD2/Cycle 36 - frozen cycle for international code assessment; (4) updates to cycle 36 based on recommendations developed by B and W during the simulation of a Massachusetts Institute of Technology (MIT) pressurizer test; and (5) cycle 36.1 updates received from EG and G.

  7. Modification of the bubble rise model used in RELAP4/Mod5 computer code for transients analysis

    International Nuclear Information System (INIS)

    Scharfmann, E.

    1981-01-01

    To improve the separation phase and heat transfer models in RELAP4/MOD5 computer code, in order to make more realistic estimates of the thermohydraulic behavior of the core submitted to a loss-of-coolant accident, is the objective of this work. This research is directed to the accident analysis caused by small breaks in the primary circuit of PWR plants, where two-phase flow occurs most of the time. Calculation have been performed with the help of the original version of RELAP code, and the version containing the proposed modifications on this work. Comparing one results with the original ones, we arrive at the conclusion that our results show more conservative values of core pressure and coolant temperature, while the peak values of fuel temperature are not exceeded. (Author) [pt

  8. SURE: a system of computer codes for performing sensitivity/uncertainty analyses with the RELAP code

    International Nuclear Information System (INIS)

    Bjerke, M.A.

    1983-02-01

    A package of computer codes has been developed to perform a nonlinear uncertainty analysis on transient thermal-hydraulic systems which are modeled with the RELAP computer code. Using an uncertainty around the analyses of experiments in the PWR-BDHT Separate Effects Program at Oak Ridge National Laboratory. The use of FORTRAN programs running interactively on the PDP-10 computer has made the system very easy to use and provided great flexibility in the choice of processing paths. Several experiments simulating a loss-of-coolant accident in a nuclear reactor have been successfully analyzed. It has been shown that the system can be automated easily to further simplify its use and that the conversion of the entire system to a base code other than RELAP is possible

  9. Analysis of eventual accidents in a water experimental loop, using the Relap 4 computer code

    International Nuclear Information System (INIS)

    Fernandes Filho, T.L.

    1981-01-01

    Transients caused by accidents as (1) loss of coolant, (2) failure in the principal pump and (3) power excursions were analysed. In the accident simulation, the Relap 4/Mod 3 computer code was used. The results obtained with the steady state model showed to be consistent with the project-and operation data of the experimental loop. For all the accidents analysed that considered the performance of safety systems, the highest temperature of the heating rods in the testing section did not exceed the permissible temperature. (E.G.) [pt

  10. Installation and validation of RELAP4/MOD6 on the VAX 11/780 computer at IKE

    International Nuclear Information System (INIS)

    Lang, U.; Haussmann, C.

    1983-06-01

    RELAP4/MOD6 is a FORTRAN 4 code for the transient thermohydraulic analysis of nuclear reactors and similar systems. This code has been developed by the Idaho National Engeneering Laboratory for CDC and IBM computers. The implementation of the code on a VAX 11/780 has been possible due to the fact, that this computer is a byte oriented system as the IBM machines, and that the code has been wirtten only in part in a machine dependent way. Two versions of RELAP4/MOD6 are available on the VAX-system, with different dimensions for the input parameters (SI-units or BTU-units). The implementation of the two versions and their validation is described in this report. (orig.) [de

  11. Experiment predictions of LOFT reflood behavior using the RELAP4/MOD6 code

    International Nuclear Information System (INIS)

    Lin, J.C.; Kee, E.J.; Grush, W.H.; White, J.R.

    1978-01-01

    The RELAP4/MOD6 computer code was used to predict the thermal-hydraulic transient for Loss-of-Fluid Test (LOFT) Loss-of-Coolant Accident (LOCA) experiments L2-2, L2-3, and L2-4. This analysis will aid in the development and assessment of analytical models used to analyze the LOCA performance of commercial power reactors. Prior to performing experiments in the LOFT facility, the experiments are modeled in counterpart tests performed in the nonnuclear Semiscale MOD 1 facility. A comparison of the analytical results with Semiscale data will verify the analytical capability of the RELAP4 code to predict the thermal-hydraulic behavior of the Semiscale LOFT counterpart tests. The analytical model and the results of analyses for the reflood portion of the LOFT LOCA experiments are described. These results are compared with the data from Semiscale

  12. LFTPLT8: plotter program for RELAP5 code

    International Nuclear Information System (INIS)

    Yamano, Kazuaki; Abe, Nobuaki; Tasaka, Kanji

    1981-02-01

    The plotter program LFTPLT8 is a new version of the LFTPLT7 developed to plot the calculated results by RELAP5 code. The RELAP5/MOD0 code has also been revised for LFTPLT8. LFTPLT8 is capable of multiple plotting of any combination of experimental data and calculated results by RELAP4J, RELAP4/MOD5, ALARM-P1, and RELAP5/MOD0. (author)

  13. Linking of FRAP-T, FRAPCON and RELAP-4 codes for transient analysis and accidents of light water reactors fuel rods

    International Nuclear Information System (INIS)

    Marra Neto, A.; Silva, A.T. e; Sabundjian, G.; Freitas, R.L.; Neves Conti, T. das.

    1991-09-01

    The computer codes FRAP-T, FRAPCON and RELAP-4 have been linked for the fuel rod behavior analysis under transients and hypothetical accidents in light water reactors. The results calculated by thermal hydraulic code RELAP-4 give input in file format into the transient fuel analysis code FRAP-T. If the effect of fuel burnup is taken into account, the fuel performance code FRAPCON should provide the initial steady state data for thhe transient analysis. With the thermal hydraulic boundary conditions provided by RELAP-4 (MOD3), FRAP-T6 is used to analyse pressurized water reactor fuel rod behavior during the blowdown phase under large break loss of coolant accident conditions. Two cases have been analysed: without and with initialization from FRAPCON-2 steady state data. (author)

  14. Modifications of the bubble rise model and heat transfer model used in RELAP 4/Mod 5 computer code for transient analysis

    International Nuclear Information System (INIS)

    Scharfmann, E.; Silva, D.E. da

    1981-01-01

    The modifications on the phase separation model and heat tranfer model in Relap4/Mod 5 computer code, in order to make more realistic estimates of the core thermohydraulic behavior submitted to a loss of coolant accident. This research is directed to the accident analysis caused by small breaks in the primary circuits of PWR plants, where two-phase flow occurs most of the time. Calculation have been performed with the help of the original version of Relap code, as well as the version containing the proposed modifications on this work. Comparing one results with the original ones, we arrive at the conclusion that our results show more conservative values of core pressure and coolant temperature, while the peak values of fuel temperature are not exceeded. (Author) [pt

  15. Improved guidelines for RELAP4/MOD6 reflood calculations

    International Nuclear Information System (INIS)

    Chen, T.H.; Fletcher, C.D.

    1980-01-01

    Computer simulations were performed for an extensive selection of forced- and gravity-feed reflood experiments. This effort was a portion of the assessment procedure for the RELAP4/MOD6 thermal hydraulic computer code. A common set of guidelines, based on recommendations from the code developers, was used in determining the model and user-selected input options for each calculation. The comparison of code-calculated and experimental data was then used to assess the capability of the RELAP4/MOD6 code to model the reflood phenomena. As a result of the assessment, the guidelines for determining the user-selected input options were improved

  16. Influence of Modelling Options in RELAP5/SCDAPSIM and MAAP4 Computer Codes on Core Melt Progression and Reactor Pressure Vessel Integrity

    Directory of Open Access Journals (Sweden)

    Siniša Šadek

    2010-01-01

    Full Text Available RELAP5/SCDAPSIM and MAAP4 are two widely used severe accident computer codes for the integral analysis of the core and the reactor pressure vessel behaviour following the core degradation. The objective of the paper is the comparison of code results obtained by application of different modelling options and the evaluation of influence of thermal hydraulic behaviour of the plant on core damage progression. The analysed transient was postulated station blackout in NPP Krško with a leakage from reactor coolant pump seals. Two groups of calculations were performed where each group had a different break area and, thus, a different leakage rate. Analyses have shown that MAAP4 results were more sensitive to varying thermal hydraulic conditions in the primary system. User-defined parameters had to be carefully selected when the MAAP4 model was developed, in contrast to the RELAP5/SCDAPSIM model where those parameters did not have any significant impact on final results.

  17. Data calculation program for RELAP 5 code

    International Nuclear Information System (INIS)

    Silvestre, Larissa J.B.; Sabundjian, Gaiane

    2015-01-01

    As the criteria and requirements for a nuclear power plant are extremely rigid, computer programs for simulation and safety analysis are required for certifying and licensing a plant. Based on this scenario, some sophisticated computational tools have been used such as the Reactor Excursion and Leak Analysis Program (RELAP5), which is the most used code for the thermo-hydraulic analysis of accidents and transients in nuclear reactors. A major difficulty in the simulation using RELAP5 code is the amount of information required for the simulation of thermal-hydraulic accidents or transients. The preparation of the input data leads to a very large number of mathematical operations for calculating the geometry of the components. Therefore, a mathematical friendly preprocessor was developed in order to perform these calculations and prepare RELAP5 input data. The Visual Basic for Application (VBA) combined with Microsoft EXCEL demonstrated to be an efficient tool to perform a number of tasks in the development of the program. Due to the absence of necessary information about some RELAP5 components, this work aims to make improvements to the Mathematic Preprocessor for RELAP5 code (PREREL5). For the new version of the preprocessor, new screens of some components that were not programmed in the original version were designed; moreover, screens of pre-existing components were redesigned to improve the program. In addition, an English version was provided for the new version of the PREREL5. The new design of PREREL5 contributes for saving time and minimizing mistakes made by users of the RELAP5 code. The final version of this preprocessor will be applied to Angra 2. (author)

  18. Data calculation program for RELAP 5 code

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre, Larissa J.B.; Sabundjian, Gaiane, E-mail: larissajbs@usp.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    As the criteria and requirements for a nuclear power plant are extremely rigid, computer programs for simulation and safety analysis are required for certifying and licensing a plant. Based on this scenario, some sophisticated computational tools have been used such as the Reactor Excursion and Leak Analysis Program (RELAP5), which is the most used code for the thermo-hydraulic analysis of accidents and transients in nuclear reactors. A major difficulty in the simulation using RELAP5 code is the amount of information required for the simulation of thermal-hydraulic accidents or transients. The preparation of the input data leads to a very large number of mathematical operations for calculating the geometry of the components. Therefore, a mathematical friendly preprocessor was developed in order to perform these calculations and prepare RELAP5 input data. The Visual Basic for Application (VBA) combined with Microsoft EXCEL demonstrated to be an efficient tool to perform a number of tasks in the development of the program. Due to the absence of necessary information about some RELAP5 components, this work aims to make improvements to the Mathematic Preprocessor for RELAP5 code (PREREL5). For the new version of the preprocessor, new screens of some components that were not programmed in the original version were designed; moreover, screens of pre-existing components were redesigned to improve the program. In addition, an English version was provided for the new version of the PREREL5. The new design of PREREL5 contributes for saving time and minimizing mistakes made by users of the RELAP5 code. The final version of this preprocessor will be applied to Angra 2. (author)

  19. Mathematic preprocessor for RELAP5 code using Microsoft Excel

    International Nuclear Information System (INIS)

    Paladino, Patricia Andrea

    2006-01-01

    Computational program are used for thermal hydraulic analysis of accidents and transients conditions in nuclear power plants. The RELAP5 code has been developed to simulate accidents and transients conditions, performing a best estimate analysis, in Pressurized Water Reactors (PWR) and auxiliary systems. The RELAP5 code, which has been used as a toll for licensing nuclear facilities in Brazil, is the objective of the study performed in this work. The main problem in using the RELAP5 code is the huge amount of information necessary to model the nuclear reactor and thus to simulate thermal-hydraulic accidents. Moreover, the RELAP5 code input data requires a large amount of mathematical operations to calculate the geometry of the plant components. Therefore, in order to make easier the data input for the RELAP5 code a friendly preprocessor has been developed. The preprocessor accepts basic information about the geometry of the plant components and performs all the calculations needed for the RELAP5 input. This preprocessor has been developed based on the MS-Excel software. (author)

  20. RELAP5/MOD3 code manual. Volume 4, Models and correlations

    International Nuclear Information System (INIS)

    1995-08-01

    The RELAP5 code has been developed for best-estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents and operational transients such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I presents modeling theory and associated numerical schemes; Volume II details instructions for code application and input data preparation; Volume III presents the results of developmental assessment cases that demonstrate and verify the models used in the code; Volume IV discusses in detail RELAP5 models and correlations; Volume V presents guidelines that have evolved over the past several years through the use of the RELAP5 code; Volume VI discusses the numerical scheme used in RELAP5; and Volume VII presents a collection of independent assessment calculations

  1. Steady-state simulations of a 30-tube once-through steam generator with the RELAP5/MOD3 and RELAP5/MOD2 computer codes

    International Nuclear Information System (INIS)

    Hassan, Y.A.; Salim, P.

    1991-01-01

    This paper reports on a steady-state analysis of a 30-tube once-through steam generator that has been performed on the RELAPS/MOD3 and RELAPS/MOD2 computer codes for 100, 75, and 65% loads. Results obtained are compared with experimental data. The RELAP5/MOD3 results for the test facility generally agree reasonably well with the data for the primary-side temperature profiles. The secondary-side temperature profile predicted by RELAP5/MOD3 at 75 and 65% loads agrees fairly well with the data and is better than the RELAP5/MOD2 results. However, the RELAP5/MOD3 calculated secondary-side temperature profile does not compare well with the 100% load data

  2. Development and assessment of the COBRA/RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jae Jun; Ha, Kwi Seok; Sim, Seok Ku

    1997-04-01

    The COBRA/RELAP5 code, a merged version of the COBRA-TF and RELAP5/MOD3.2 codes, has been developed to combine the realistic three-dimensional reactor vessel model of COBRA-TF with RELAP5/MOD3, thus to produce an advanced system analysis code with a multidimensional thermal-hydraulic module. This report provides the integration scheme of the two codes and the results of developmental assessments. These includes single channel tests, manometric flow oscillation problem, THTF Test 105, and LOFT L2-3 large-break loss-of-coolant experiment. From the single channel tests the integration scheme and its implementation were proven to be valid. Other simulation results showed good agreement with the experiments. The computational speed was also satisfactory. So it is confirmed that COBRA/RELAP5 can be a promising tool for analysis of complicated, multidimensional two-phase flow transients. The area of further improvements in the code integration are also identified. This report also serves as a user`s manual for the COBRA/RELAP5 code. (author). 6 tabs., 20 figs., 20 refs.

  3. SCDAP/RELAP5 code development and assessment

    International Nuclear Information System (INIS)

    Allison, C.M.; Hohorst, J.K.

    1996-01-01

    The SCDAP/RELAP5 computer code is designed to describe the overall reactor coolant system thermal-hydraulic response, core damage progression, and fission product release during severe accidents. The code is being developed at the Idaho National Engineering Laboratory under the primary sponsorship of the Office of Nuclear Regulatory Research of the U.S. Nuclear Regulatory Commission. The current version of the code is SCDAP/RELAP5/MOD3.1e. Although MOD3.1e contains a number of significant improvements since the initial version of MOD3.1 was released, new models to treat the behavior of the fuel and cladding during reflood have had the most dramatic impact on the code's calculations. This paper provides a brief description of the new reflood models, presents highlights of the assessment of the current version of MOD3.1, and discusses future SCDAP/RELAP5/MOD3.2 model development activities

  4. A comparative simulation of feed and bleed operation during the total loss of feedwater event by RELAP5/MOD3 and CEFLASH-4AS/REM computer codes

    International Nuclear Information System (INIS)

    Kwon, Y.M.; Ro, T.S.; Song, J.H.

    1995-01-01

    The Ulchin 3 and 4 nuclear power plants, which are two-loop 2,825 MW(thermal) pressurized water reactors designed by the Korea Atomic Energy Research Institute, adopted a safety depressurization system (SDS) to mitigate the beyond-design-basis event of a total loss of feedwater (TLOFW). A comparative simulation by the CEFLASH-4AS/REM and RELAP5/MOD3 computer codes for the TLOFW event without operator recovery and the TLOFW event with feed and bleed (F and B) operation is performed for Ulchin 3 and 4. In the analyses, the SDS bleed paths are modeled by orifices located on the top of the pressurizer, where the analytical area of the bleed path is based on the Ulchin 3 and 4 SDS design flow capacity. An additional case, where the SDS piping and valves are modeled explicitly, is considered for the RELAP5 analysis. The predictions by the CEFLASH-4AS/REM of the transient two-phase system behavior show good qualitative and quantitative agreement with those by the RELAP5 simulation. The RELAP5 case with explicit piping results in less repressurization and lower reactor coolant system pressure than that of the case without explicit SDS modeling. However, the two cases of RELAP5 analyses result in essentially the same transient scenarios for TLOFW with F and B operation. The results of the simulation demonstrate the validity of the Ulchin 3 and 4 design approach, which employs CEFLASH-4AS/REM computer code and SDS bleed paths modeled by orifices located on the top of the pressurizer. The results also indicate that the decay heat removal and core inventory makeup function can be successfully accomplished by F and B operation by using the SDS for Ulchin 3 and 4

  5. RELAP-7 Code Assessment Plan and Requirement Traceability Matrix

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Junsoo; Choi, Yong-joon; Smith, Curtis L.

    2016-10-01

    The RELAP-7, a safety analysis code for nuclear reactor system, is under development at Idaho National Laboratory (INL). Overall, the code development is directed towards leveraging the advancements in computer science technology, numerical solution methods and physical models over the last decades. Recently, INL has also been putting an effort to establish the code assessment plan, which aims to ensure an improved final product quality through the RELAP-7 development process. The ultimate goal of this plan is to propose a suitable way to systematically assess the wide range of software requirements for RELAP-7, including the software design, user interface, and technical requirements, etc. To this end, we first survey the literature (i.e., international/domestic reports, research articles) addressing the desirable features generally required for advanced nuclear system safety analysis codes. In addition, the V&V (verification and validation) efforts as well as the legacy issues of several recently-developed codes (e.g., RELAP5-3D, TRACE V5.0) are investigated. Lastly, this paper outlines the Requirement Traceability Matrix (RTM) for RELAP-7 which can be used to systematically evaluate and identify the code development process and its present capability.

  6. Utilization of the RELAP4/MOD5/SAS code version in loss of coolant accident in the Angra 1 nuclear power station

    International Nuclear Information System (INIS)

    Sabundjian, G.; Freitas, R.L.

    1991-09-01

    A new version of computer code RELAP4/MOD5 was developed to improve the output. The new version, called RELAP4/MOD5/SAS, prints the main variables in graphical form. In order to check the program, a 36 - volume simulation of the Loss-of-Coolant Accident for Angra - I was performed and the results compared to those of a existing 44 - volume simulation showed a satisfactory agreement with a substantial reduction in computing time. (author)

  7. SCDAP/RELAP5/MOD3 code development

    International Nuclear Information System (INIS)

    Allison, C.M.; Siefken, J.L.; Coryell, E.W.

    1992-01-01

    The SCOAP/RELAP5/MOD3 computer code is designed to describe the overall reactor coolant system (RCS) thermal-hydraulic response, core damage progression, and fission product release and transport during severe accidents. The code is being developed at the Idaho National Engineering Laboratory (INEL) under the primary sponsorship of the Office of Nuclear Regulatory Research of the US Nuclear Regulatory Commission (NRC). Code development activities are currently focused on three main areas - (a) code usability, (b) early phase melt progression model improvements, and (c) advanced reactor thermal-hydraulic model extensions. This paper describes the first two activities. A companion paper describes the advanced reactor model improvements being performed under RELAP5/MOD3 funding

  8. Assessment of 12 CHF prediction methods, for an axially non-uniform heat flux distribution, with the RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Ferrouk, M. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria)], E-mail: m_ferrouk@yahoo.fr; Aissani, S. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria); D' Auria, F.; DelNevo, A.; Salah, A. Bousbia [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa (Italy)

    2008-10-15

    The present article covers the evaluation of the performance of twelve critical heat flux methods/correlations published in the open literature. The study concerns the simulation of an axially non-uniform heat flux distribution with the RELAP5 computer code in a single boiling water reactor channel benchmark problem. The nodalization scheme employed for the considered particular geometry, as modelled in RELAP5 code, is described. For this purpose a review of critical heat flux models/correlations applicable to non-uniform axial heat profile is provided. Simulation results using the RELAP5 code and those obtained from our computer program, based on three type predictions methods such as local conditions, F-factor and boiling length average approaches were compared.

  9. Streamlining of the RELAP5-3D Code

    International Nuclear Information System (INIS)

    Mesina, George L; Hykes, Joshua; Guillen, Donna Post

    2007-01-01

    RELAP5-3D is widely used by the nuclear community to simulate general thermal hydraulic systems and has proven to be so versatile that the spectrum of transient two-phase problems that can be analyzed has increased substantially over time. To accommodate the many new types of problems that are analyzed by RELAP5-3D, both the physics and numerical methods of the code have been continuously improved. In the area of computational methods and mathematical techniques, many upgrades and improvements have been made decrease code run time and increase solution accuracy. These include vectorization, parallelization, use of improved equation solvers for thermal hydraulics and neutron kinetics, and incorporation of improved library utilities. In the area of applied nuclear engineering, expanded capabilities include boron and level tracking models, radiation/conduction enclosure model, feedwater heater and compressor components, fluids and corresponding correlations for modeling Generation IV reactor designs, and coupling to computational fluid dynamics solvers. Ongoing and proposed future developments include improvements to the two-phase pump model, conversion to FORTRAN 90, and coupling to more computer programs. This paper summarizes the general improvements made to RELAP5-3D, with an emphasis on streamlining the code infrastructure for improved maintenance and development. With all these past, present and planned developments, it is necessary to modify the code infrastructure to incorporate modifications in a consistent and maintainable manner. Modifying a complex code such as RELAP5-3D to incorporate new models, upgrade numerics, and optimize existing code becomes more difficult as the code grows larger. The difficulty of this as well as the chance of introducing errors is significantly reduced when the code is structured. To streamline the code into a structured program, a commercial restructuring tool, FOR( ) STRUCT, was applied to the RELAP5-3D source files. The

  10. Integrated uncertainty analysis using RELAP/SCDAPSIM/MOD4.0

    International Nuclear Information System (INIS)

    Perez, M.; Reventos, F.; Wagner, R.; Allison, C.

    2009-01-01

    The RELAP/SCDAPSIM/MOD4.0 code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed as part of an international nuclear technology Software Development and Training Program (SDTP). RELAP/SCDAPSIM/MOD4.0, which is the first version of RELAP5 completely rewritten to FORTRAN 90/95/2000 standards, uses the publicly available RELAP5 and SCDAP models in combination with (a) advanced programming and numerical techniques, (b) advanced SDTP-member-developed models for LWR, HWR, and research reactor analysis, and (c) a variety of other member-developed computational packages. One such computational package is an integrated uncertainty analysis package being developed jointly by the Technical University of Catalunya (UPC) and Innovative Systems Software (ISS). The integrated uncertainty analysis approach used in the package uses the following steps: 1. Selection of the plant; 2. Selection of the scenario; 3. Selection of the safety criteria; 4. Identification and ranking of the relevant phenomena based on the safety criteria; 5. Selection of the appropriate code parameters to represent those phenomena; 6. Association of uncertainty by means of Probability Distribution Functions (PDFs) for each selected parameter; 7. Random sampling of the selected parameters according to its PDF and performing multiple computer runs to obtain uncertainty bands with a certain percentile and confidence level; 8. Processing the results of the multiple computer runs to estimate the uncertainty bands for the computed quantities associated with the selected safety criteria. The first four steps are performed by the user prior to the RELAP/SCDAPSIM/MOD4.0 analysis. The remaining steps are included with the MOD4.0 integrated uncertainty analysis (IUA) package. This paper briefly describes the integrated uncertainty analysis package including (a) the features of the package, (b) the implementation of the package into RELAP/SCDAPSIM/MOD4.0, and

  11. Utilization of Relap 5 computer code for analyzing thermohydraulic projects

    International Nuclear Information System (INIS)

    Silva Filho, E.

    1987-01-01

    This work deals with the design of a scaled test facility of a typical pressurized water reactor plant of the 1300 MW (electric) class. A station blackout has been choosen to investigate the thermohydraulic behaviour of the the test facility in comparison to the reactor plant. The computer code RELAPS/MOD1 has been utilized to simulate the blackout and to compare the test facility behaviour with the reactor plant one. The results demonstrate similar thermohydraulic behaviours of the two systems. (author) [pt

  12. Comparative severe accident analysis of WWER 1000/B 320 LOCA DN100 computed by computer codes ASTEC V1.1 and SCDAP/RELAP5

    International Nuclear Information System (INIS)

    Kalchev, B.; Dimov, D.; Tusheva, P.; Mladenov, I.

    2005-01-01

    This paper presents the modelling approach for LOCA 100 mm sequence for WWER 1000-B 320 type of reactor with the integral ASTEC computer code and SCDAP/RELAP5 computer code. As a basic input deck the reference input file for Balakovo NPP from the released ASTEC CD has been applied. As a first part of the calculations for the SBLOCA sequence the ASTEC v1.1 modules CESAR, DIVA and CPA have been activated in a coupled mode. For SCDAP/RELAP5 calculation input deck for WWER 1000-B 320 has been applied which meant to be closer to the initial boundary conditions applied for ASTEC WWER 1000 input deck. A SBLOCA 100 mm comparison between ASTEC v1.1 and SCADAP/RELAP5 has been presented. ASTEC predicts vessel failure at 15620 s. ASTEC and SCDAP/RELAP5 give close but not similar results - this could be observed on the trends. The comparison of 100 mm-break shows that SCDAP/RELAP5 predicts clear phenomenological changes in primary pressure evolution and molten pool formation. Similar hydrogen production mass for both codes around 5000 s is detected

  13. RELAP5/MOD3 code coupling model

    International Nuclear Information System (INIS)

    Martin, R.P.; Johnsen, G.W.

    1994-01-01

    A new capability has been incorporated into RELAP5/MOD3 that enables the coupling of RELAP5/MOD3 to other computer codes. The new capability has been designed to support analysis of the new advanced reactor concepts. Its user features rely solely on new RELAP5 open-quotes styledclose quotes input and the Parallel Virtual Machine (PVM) software, which facilitates process management and distributed communication of multiprocess problems. RELAP5/MOD3 manages the input processing, communication instruction, process synchronization, and its own send and receive data processing. The flexible capability requires that an explicit coupling be established, which updates boundary conditions at discrete time intervals. Two test cases are presented that demonstrate the functionality, applicability, and issues involving use of this capability

  14. RELAP5-3D Code Includes ATHENA Features and Models

    International Nuclear Information System (INIS)

    Riemke, Richard A.; Davis, Cliff B.; Schultz, Richard R.

    2006-01-01

    Version 2.3 of the RELAP5-3D computer program includes all features and models previously available only in the ATHENA version of the code. These include the addition of new working fluids (i.e., ammonia, blood, carbon dioxide, glycerol, helium, hydrogen, lead-bismuth, lithium, lithium-lead, nitrogen, potassium, sodium, and sodium-potassium) and a magnetohydrodynamic model that expands the capability of the code to model many more thermal-hydraulic systems. In addition to the new working fluids along with the standard working fluid water, one or more noncondensable gases (e.g., air, argon, carbon dioxide, carbon monoxide, helium, hydrogen, krypton, nitrogen, oxygen, SF 6 , xenon) can be specified as part of the vapor/gas phase of the working fluid. These noncondensable gases were in previous versions of RELAP5-3D. Recently four molten salts have been added as working fluids to RELAP5-3D Version 2.4, which has had limited release. These molten salts will be in RELAP5-3D Version 2.5, which will have a general release like RELAP5-3D Version 2.3. Applications that use these new features and models are discussed in this paper. (authors)

  15. RELAP4 stagnation properties option

    International Nuclear Information System (INIS)

    DeYoung, T.L.

    1979-01-01

    The stagnation properties option in RELAP4/MOD6 was completely reviewed, from theoretical foundation to code application. The result of this investigation was the identification of a fundamental mismatch between the essentially homogeneous, equilibrium-based, RELAP4 code and the nonhomogeneous and/or nonequilibrium critical flow models imposed on the code. By continuously monitoring fluid Mach numbers and adjusting flow areas such that sonic velocity was never exceeded, the mismatch could be accommodated. This approach was implemented, found to work correctly, and will be incorporated into the MOD7 version of the code

  16. RELAP/REFLA (Mod 0): a system reflooding analysis computer program

    International Nuclear Information System (INIS)

    Fujiki, Kazuo; Murao, Yoshio; Shimooke, Takanori.

    1981-03-01

    A new computer code RELAP/REFLA has been developed, aiming at analyses of the core reflooding phenomena during the postulated loss-of-coolant accident of PWRs. The code was originated from the combination of two distinct codes, RELAP4-FLOOD and REFLA-1D. The characteristics of the code are: (1) Kinematical model based on the observation and analysis of quench experiments is used for the thermal-hydraulic analysis of reflooding core, (2) it has the capability to analyse the reflooding phenomena in an arbitrary type of PWR or experimental facility, including the system feedback effects, (3) the flow paths in the actual system are represented by the combination of 1-dimentional flow paths, and vapor-liquid equilibrium model is applied except the reflooding core. This report is a code manual of RELAP/REFLA (version Mod 0) and contains the descriptions of the basic models, basic equations, code structure and input format. The calculated results of two kinds of sample problems, i.e., reflooding problem on the 4 loop PWR and FLECHT-SET experiment, are also presented. Relatively close agreement between FLECHT-SET data and the calculated results was obtained for the lower portion of the core, but poor agreement for the temperature histories in the upper core and carryover ratio. Running speed and core memory size are almost equal to those of RELAP 4/Mod 3. (author)

  17. SCDAP/RELAP5/MOD3 code development and assessment

    International Nuclear Information System (INIS)

    Allison, C.M.; Heath, C.H.; Siefken, L.J.; Hohorst, J.K.

    1991-01-01

    The SCDAP/RELAP5/MOD3 computer code is designed to describe the overall reactor coolant system (RCS) thermal-hydraulic response, core damage progression, and fission product release and transport during severe accidents. The code is being developed at the Idaho National Engineering Laboratory (INEL) under the primary sponsorship of the Office of Nuclear Regulatory Research of the Nuclear Regulatory Commission (NRC). SCDAP/RELAP5/MOD3, created in January, 1991, is the result of merging RELAP5/MOD3 with SCDAP and TRAP-MELT models from SCDAP/RELAP5/MOD2.5. The RELAP5 models calculate the overall RCS thermal-hydraulics, control system interactions, reactor kinetics, and the transport of noncondensible gases, fission products, and aerosols. The SCDAP models calculate the damage progression in the core structures, the formation, heatup, and melting of debris, and the creep rupture failure of the lower head and other RCS structures. The TRAP-MELT models calculate the deposition of fission products upon aerosols or structural surfaces; the formation, growth, or deposition of aerosols; and the evaporation of species from surfaces. The systematic assessment of modeling uncertainties in SCDAP/RELAP5 code is currently underway. This assessment includes (a) the evaluation of code-to-data comparisons using stand-alone SCDAP and SCDAP/RELAP5/MOD3, (b) the estimation of modeling and experimental uncertainties, and (c) the determination of the influence of those uncertainties on predicted severe accident behavior

  18. Vectorization and improvement of nuclear codes (MEUDAS4, FORCE, STREAM V2.6, HEATING7-VP, SCDAP/RELAP5/MOD2.5, NBI3DGFN)

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Suzuki, Koichiro; Isobe, Nobuo; Machida, Masahiko; Osanai, Seiji; Yokokawa, Mitsuo

    1992-09-01

    Eight nuclear codes have been vectorized and modified to improve their performance. These codes are magnetic fluid equilibrium code MEUDAS4 (CR and FFT versions), the magnetic field analysis code FORCE, the three-dimensional heat fluid analysis code STREAM V2.6, the three-dimensional heat analysis code HEATING 7-VP, the severe accident transient analysis code SCDAP/RELAP 5/MOD 2.5 for light water reactors, the ion beam orbital analysis code NBI3DGFN, and a free electron laser analysis code. The speedup ratios of the vectorized versions to the original ones in scalar mode are 2.3-4.9, 1.9-5.4, 2.6-6.2, and 1.9 for the MEUDAS4, STREAM, FORCE, and free electron laser analysis code, respectively. The definition method of the computational regions in the HEATING7-VP is improved. The SCDAP/RELAP5/MOD2.5 is modified to use extended memory regions of the computer. In this report, outlines of the codes, techniques used in the vectorization and reorganization of the codes, verification of computed results, and improvement on the performance are presented. (author)

  19. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Supplement 1, RELAP4/MOD5, Update 2

    International Nuclear Information System (INIS)

    Bruch, C.G.

    1976-08-01

    RELAP4/MOD5, Update 1 was released to the Nuclear Regulatory Commission in January 1976. Six months of extensive use of Update 1 has led to the identification and correction of a number of errors in the code, as well as some logic changes, additional Evaluation Model (EM) checks, and one model revision. These changes have culminated in the release of an improved code identified as RELAP4/MOD5, Update 2. The RELAP4/MOD5 interim User's Manual (Interim Report SRD-113-76) reflected the Update 1 version of the code. The purpose of the supplement presented is to update the Interim User's Manual for use with RELAP4/MOD5, Update 2. Major differences between Updates 1 and 2 and the checkout of Update 2 are discussed. The final version of the User's Manual will be written in accordance with Update 2 and will be published as ANCR-NUREG 1335 during September 1976. Annotation of the existing three volumes of the User's Manual to cross-reference this Supplement is recommended

  20. Mathematic preprocessor for RELAP5 code using Microsoft Excel; Pre-processador matematico para o codigo RELAP5 utilizando o Microsoft Excel

    Energy Technology Data Exchange (ETDEWEB)

    Paladino, Patricia Andrea

    2006-07-01

    Computational program are used for thermal hydraulic analysis of accidents and transients conditions in nuclear power plants. The RELAP5 code has been developed to simulate accidents and transients conditions, performing a best estimate analysis, in Pressurized Water Reactors (PWR) and auxiliary systems. The RELAP5 code, which has been used as a toll for licensing nuclear facilities in Brazil, is the objective of the study performed in this work. The main problem in using the RELAP5 code is the huge amount of information necessary to model the nuclear reactor and thus to simulate thermal-hydraulic accidents. Moreover, the RELAP5 code input data requires a large amount of mathematical operations to calculate the geometry of the plant components. Therefore, in order to make easier the data input for the RELAP5 code a friendly preprocessor has been developed. The preprocessor accepts basic information about the geometry of the plant components and performs all the calculations needed for the RELAP5 input. This preprocessor has been developed based on the MS-Excel software. (author)

  1. Validation of one-dimensional module of MARS 2.1 computer code by comparison with the RELAP5/MOD3.3 developmental assessment results

    International Nuclear Information System (INIS)

    Lee, Y. J.; Bae, S. W.; Chung, B. D.

    2003-02-01

    This report records the results of the code validation for the one-dimensional module of the MARS 2.1 thermal hydraulics analysis code by means of result-comparison with the RELAP5/MOD3.3 computer code. For the validation calculations, simulations of the RELAP5 code development assessment problem, which consists of 22 simulation problems in 3 categories, have been selected. The results of the 3 categories of simulations demonstrate that the one-dimensional module of the MARS 2.1 code and the RELAP5/MOD3.3 code are essentially the same code. This is expected as the two codes have basically the same set of field equations, constitutive equations and main thermal hydraulic models. The results suggests that the high level of code validity of the RELAP5/MOD3.3 can be directly applied to the MARS one-dimensional module

  2. Thermohydraulic analysis of nuclear power plant accidents by computer codes

    International Nuclear Information System (INIS)

    Petelin, S.; Stritar, A.; Istenic, R.; Gregoric, M.; Jerele, A.; Mavko, B.

    1982-01-01

    RELAP4/MOD6, BRUCH-D-06, CONTEMPT-LT-28, RELAP5/MOD1 and COBRA-4-1 codes were successful y implemented at the CYBER 172 computer in Ljubljana. Input models of NPP Krsko for the first three codes were prepared. Because of the high computer cost only one analysis of double ended guillotine break of the cold leg of NPP Krsko by RELAP4 code has been done. BRUCH code is easier and cheaper for use. Several analysis have been done. Sensitivity study was performed with CONTEMPT-LT-28 for double ended pump suction break. These codes are intended to be used as a basis for independent safety analyses. (author)

  3. PCRELAP5: data calculation program for RELAP 5 code

    International Nuclear Information System (INIS)

    Silvestre, Larissa Jacome Barros

    2016-01-01

    Nuclear accidents in the world led to the establishment of rigorous criteria and requirements for nuclear power plant operations by the international regulatory bodies. By using specific computer programs, simulations of various accidents and transients likely to occur at any nuclear power plant are required for certifying and licensing a nuclear power plant. Based on this scenario, some sophisticated computational tools have been used such as the Reactor Excursion and Leak Analysis Program (RELAP5), which is the most widely used code for the thermo-hydraulic analysis of accidents and transients in nuclear reactors in Brazil and worldwide. A major difficulty in the simulation by using RELAP5 code is the amount of information required for the simulation of thermal-hydraulic accidents or transients. The preparation of the input data requires a great number of mathematical operations to calculate the geometry of the components. Thus, for those calculations performance and preparation of RELAP5 input data, a friendly mathematical preprocessor was designed. The Visual Basic for Application (VBA) for Microsoft Excel demonstrated to be an effective tool to perform a number of tasks in the development of the program. In order to meet the needs of RELAP5 users, the RELAP5 Calculation Program (Programa de Calculo do RELAP5 - PCRELAP5) was designed. The components of the code were codified; all entry cards including the optional cards of each one have been programmed. In addition, an English version for PCRELAP5 was provided. Furthermore, a friendly design was developed in order to minimize the time of preparation of input data and errors committed by users. In this work, the final version of this preprocessor was successfully applied for Safety Injection System (SIS) of Angra 2. (author)

  4. The calculation of coolant leak rate through the cracks using RELAP5 code

    International Nuclear Information System (INIS)

    Krungeleviciute, V.; Kaliatka, A.

    2001-01-01

    For reason to choose method of leak detection first of all it is necessary to perform evaluating thermal-hydraulic calculations. These calculations allow to determine flow rate of discharged coolant. For coolant leak rate calculations through possible cracks in Ignalina NPP pipes SQUIRT and RELAP5 thermal-hydraulic codes were used. SQUIRT is well known as computer program that predicts the leakage for cracked pipes in NPP. As this code calculates only water (at subcooled or saturated conditions) leak rate, RELAP5 code model, that calculates water and steam leak rate, was created. For model validation comparison of SQUIRT, RELAP5 and experimental results was performed. Analysis shows RELAP5 code model suitability for calculations of leak through through-wall cracks in pipes. (author)

  5. Posttest analysis of international standard problem 10 using RELAP4/MOD7

    International Nuclear Information System (INIS)

    Hsu, M.; Davis, C.B.; Peterson, A.C. Jr.; Behling, S.R.

    1981-01-01

    RELAP4/MOD7, a best estimate computer code for the calculation of thermal and hydraulic phenomena in a nuclear reactor or related system, is the latest version in the RELAP4 code development series. This paper evaluates the capability of RELAP4/MOD7 to calculate refill/reflood phenomena. This evaluation uses the data of International Standard Problem 10, which is based on West Germany's KWU PKL refill/reflood experiment K9A. The PKL test facility represents a typical West German four-loop, 1300 MW pressurized water reactor (PWR) in reduced scale while maintaining prototypical volume-to-power ratio. The PKL facility was designed to specifically simulate the refill/reflood phase of a hypothetical loss-of-coolant accident

  6. Analysis of the natural circulation by the computer code RELAP-5

    International Nuclear Information System (INIS)

    Kordis, I.; Mavko, B.; Zeljko, M.

    1984-01-01

    The analysis of the natural circulation is one of the first analysis that was done at IJS with the computer code RELAP 5/MOS 1/CY 018. Specific model of the system was made for the natural circulation. The first 400 s of the transient were analyzed. At that time pumps are rotating only by coolant flow. First results show quite realistic picture of the transient although some changes should be made, especially on the steam generator model due to the unrealistic oscillations of the coolant flow on the secondary side. (author)

  7. RELAP4/MOD-5-CEA pump coastdown experiment simulation

    International Nuclear Information System (INIS)

    Borges, R.C.; Freitas, R.L.

    1988-07-01

    Since is important the theoretical-experimental comparison to evaluate the computer codes, these paper presents the simulation with RELAP4/MOD5 Code of a loss of power energy in the pump of the ''Circuito Experimental de Agua-CEA''. From the results attained, the existing models in the Code showed to be very satisfatory quantitative and qualitative behavior of the attained experimental results. (author) [pt

  8. R5FORCE: a program to compute fluid induced forces using hydrodynamic output from the RELAP5 code

    International Nuclear Information System (INIS)

    Watkins, J.C.

    1983-01-01

    This paper describes the computer code R5FORCE, a postprocessor to the RELAP5/MOD1 thermal-hydraulics code. R5FORCE computes piping hydraulic force/time histories that can be input into various structural analysis computer codes. R5FORCE solves the momentum conservation equation using the pressure and wall shear force terms rather than the pressure and fluid acceleration terms; eliminating potential instabilities associated with computing the time derivative in the fluid acceleration term. The updates to REALP5 required to generate the input data to R5FORCE are also discussed

  9. Validation of One-Dimensional Module of MARS-KS1.2 Computer Code By Comparison with the RELAP5/MOD3.3/patch3 Developmental Assessment Results

    International Nuclear Information System (INIS)

    Bae, S. W.; Chung, B. D.

    2010-07-01

    This report records the results of the code validation for the one-dimensional module of the MARS-KS thermal hydraulics analysis code by means of result-comparison with the RELAP5/MOD3.3 computer code. For the validation calculations, simulations of the RELAP5 Code Developmental Assessment Problem, which consists of 22 simulation problems in 3 categories, have been selected. The results of the 3 categories of simulations demonstrate that the one-dimensional module of the MARS code and the RELAP5/MOD3.3 code are essentially the same code. This is expected as the two codes have basically the same set of field equations, constitutive equations and main thermal hydraulic models. The result suggests that the high level of code validity of the RELAP5/MOD3.3 can be directly applied to the MARS one-dimensional module

  10. Heat Transfer treatment in computer codes for safety analysis

    International Nuclear Information System (INIS)

    Jerele, A.; Gregoric, M.

    1984-01-01

    Increased number of operating nuclear power plants has stressed importance of nuclear safety evaluation. For this reason, accordingly to regulatory commission request, safety analyses with computer codes are preformed. In this paper part of this thermohydraulic models dealing with wall-to-fluid heat transfer correlations in computer codes TRAC=PF1, RELAP4/MOD5, RELAP5/MOD1 and COBRA-IV is discussed. (author)

  11. Accident analysis in the water loop of the nuclear engineering department of IPEN using the RELAP4 code

    International Nuclear Information System (INIS)

    Fernandes Filho, T.L.

    1980-06-01

    A thermal-hydraulic analysis to describe the transient behavior in the water loop of the Nuclear Engineering Department of the Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo, Brazil, was performed. Postulated accidents such as those resulting from (1) loss of coolant, (2) main pump failure and (3) power excursions, were studied. The computer code RELAP4/Mod.3 was employed as the principal tool of analysis. (Author) [pt

  12. Vectorization, parallelization and implementation of nuclear codes [MVP/GMVP, QMDRELP, EQMD, HSABC, CURBAL, STREAM V3.1, TOSCA, EDDYCAL, RELAP5/MOD2/C36-05, RELAP5/MOD3] on the VPP500 computer system. Progress report 1995 fiscal year

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Watanabe, Hideo; Fujita, Toyozo; Kawai, Wataru; Harada, Hiroo; Gorai, Kazuo; Yamasaki, Kazuhiko; Shoji, Makoto; Fujii, Minoru.

    1996-07-01

    At Center for Promotion of Computational Science and Engineering, time consuming eight nuclear codes suggested by users have been vectorized, parallelized on the VPP500 computer system. In addition, two nuclear codes used on the VP2600 computer system were implemented on the VPP500 computer system. Neutron and photon transport calculation code MVP/GMVP and relativistic quantum molecular dynamics code QMDRELP have been parallelized. Extended quantum molecular dynamics code EQMD and adiabatic base calculation code HSABC have been parallelized and vectorized. Ballooning turbulence simulation code CURBAL, 3-D non-stationary compressible fluid dynamics code STREAM V3.1, operating plasma analysis code TOSCA and eddy current analysis code EDDYCAL have been vectorized. Reactor safety analysis code RELAP5/MOD2/C36-05 and RELAP5/MOD3 were implemented on the VPP500 computer system. (author)

  13. Vectorization, parallelization and implementation of nuclear codes =MVP/GMVP, QMDRELP, EQMD, HSABC, CURBAL, STREAM V3.1, TOSCA, EDDYCAL, RELAP5/MOD2/C36-05, RELAP5/MOD3= on the VPP500 computer system. Progress report 1995 fiscal year

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Toshiyuki; Watanabe, Hideo; Fujita, Toyozo [Fujitsu Ltd., Tokyo (Japan); Kawai, Wataru; Harada, Hiroo; Gorai, Kazuo; Yamasaki, Kazuhiko; Shoji, Makoto; Fujii, Minoru

    1996-06-01

    At Center for Promotion of Computational Science and Engineering, time consuming eight nuclear codes suggested by users have been vectorized, parallelized on the VPP500 computer system. In addition, two nuclear codes used on the VP2600 computer system were implemented on the VPP500 computer system. Neutron and photon transport calculation code MVP/GMVP and relativistic quantum molecular dynamics code QMDRELP have been parallelized. Extended quantum molecular dynamics code EQMD and adiabatic base calculation code HSABC have been parallelized and vectorized. Ballooning turbulence simulation code CURBAL, 3-D non-stationary compressible fluid dynamics code STREAM V3.1, operating plasma analysis code TOSCA and eddy current analysis code EDDYCAL have been vectorized. Reactor safety analysis code RELAP5/MOD2/C36-05 and RELAP5/MOD3 were implemented on the VPP500 computer system. (author)

  14. Feasibility study for improved steady-state initialization algorithms for the RELAP5 computer code

    International Nuclear Information System (INIS)

    Paulsen, M.P.; Peterson, C.E.; Katsma, K.R.

    1993-04-01

    A design for a new steady-state initialization method is presented that represents an improvement over the current method used in RELAP5. Current initialization methods for RELAP5 solve the transient fluidflow balance equations simulating a transient to achieve steady-state conditions. Because the transient solution is used, the initial conditions may change from the desired values requiring the use of controllers and long transient running times to obtain steady-state conditions for system problems. The new initialization method allows the user to fix thermal-hydraulic values in volumes and junctions where the conditions are best known and have the code compute the initial conditions in other areas of the system. The steady-state balance equations and solution methods are presented. The constitutive, component, and specialpurpose models are reviewed with respect to modifications required for the new steady-state initialization method. The requirements for user input are defined and the feasibility of the method is demonstrated with a testbed code by initializing some simple channel problems. The initialization of the sample problems using, the old and the new methods are compared

  15. Methodology, status, and plans for development and assessment of the RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, G.W.; Riemke, R.A. [Idaho National Engineering Laboratory, Idaho Falls, ID (United States)

    1997-07-01

    RELAP/MOD3 is a computer code used for the simulation of transients and accidents in light-water nuclear power plants. The objective of the program to develop and maintain RELAP5 was and is to provide the U.S. Nuclear Regulatory Commission with an independent tool for assessing reactor safety. This paper describes code requirements, models, solution scheme, language and structure, user interface validation, and documentation. The paper also describes the current and near term development program and provides an assessment of the code`s strengths and limitations.

  16. Using computer program RELAP5/MOD2 on microcomputers

    International Nuclear Information System (INIS)

    Grgic, D.; Bajs, T; Cavlina, N.; Debrecin, N.

    1990-01-01

    Our work on installation of RELAP5/MOD2 code on IBM4341, mVAX 11, MGT-386 and COMPAQ-386/20e computers is described. Main characteristics of RELAP5/MOD2 structure programming style and differences between FORTRAN VS, VAX-11 FORTRAN and NDP FORTRAN 386 are presented. We discussed basic philosophy used in modification and testing and test results. (author)

  17. RELAP 4/MOD 6 boiling water nodalization study

    International Nuclear Information System (INIS)

    Sonneck, G.; Pfau, H.

    1985-09-01

    The risk of nuclear steam supply systems is dominated by the core melt accidents. The first step to a realistic assessment of these sequences is the successful prediction of a loss of coolant event in a test loop. One of the codes for that is RELAP 4/MOD 6 and one of the important options in this code is the nodalization. The base of this work is the test LOCA No. 1 FIX II in Studsvik (Sweden) which also served as the OECD International Standard Problem 15. This report discusses the influence of different nodalizations, of different distributions of pressure, water and structural heat as well as of different bubble rise options, break flow coefficients, and heat transfer time steps. The most important result is that a simple RELAP 4/MOD6 model with less than 10 volumes is able to predict an experiment as LOCA No. 1 in FIX II successfully using only a fraction of the usual computing time. (Author)

  18. User Guide for the R5EXEC Coupling Interface in the RELAP5-3D Code

    Energy Technology Data Exchange (ETDEWEB)

    Forsmann, J. Hope [Idaho National Lab. (INL), Idaho Falls, ID (United States); Weaver, Walter L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-04-01

    This report describes the R5EXEC coupling interface in the RELAP5-3D computer code from the users perspective. The information in the report is intended for users who want to couple RELAP5-3D to other thermal-hydraulic, neutron kinetics, or control system simulation codes.

  19. Self-initialization of the RELAP4 code momentum equation

    International Nuclear Information System (INIS)

    Kern, R.C.; Hsu, M.T.

    1978-01-01

    One difficulty in using the RELAP4 code is that, owing to the overspecification of the volume and junction input data for the initial conditions, a residual friction term must be defined to establish steady-state conditions. If the corresponding residual friction coefficient is out of allowable range, the calculation is terminated at the initial data checking phase. An allowable residual friction coefficient is added to the form loss coefficient and is used throughout the transient calculation. This might affect the results if the residual friction coefficient is large. However, to model a system represented by a large number of volumes and junctions, manual adjustment of the input data, such as the pressure distribution, to reduce the effect of residual terms can take a significant amount of engineering time. A procedure that allows the code to do the adjustment internally is described

  20. Comparison of MAAP4.03 with RELAP/SCDAPSIM/MOD3.2

    Energy Technology Data Exchange (ETDEWEB)

    Kohriyama, T.; Ohtani, M. [Technical Support Project, Institute of Nuclear Technology, Institute of Nuclear Safety System, Incorporated, Mihama, Fukui (Japan); Ezzidi, A.; Morota, H. [Computer Software Development Co., Ltd., Tokyo (Japan)

    2000-11-01

    The MAAP4.03 code has been widely used for analyses of severe accident phenomena. It is, however, a system level code applying simpler models and could show phenomenological uncertainties. In order to support MAAP4.03 by a more detailed mechanistic code such as RELAP/SCDAPSIM/MOD3.2, code-to-code comparisons are performed. For a typical 4 loop PWR, analyses of two severe accident sequences were executed. Both codes predicted similar tendencies until the beginning of core melt. MAAP4.03 showed earlier slumping of molten core to a lower head of a reactor pressure vessel than RELAP/SCDAPSIM/MOD3.2. MAAP4.03 considers only axial flows of molten core and crusts suddenly breach by Creep Rupture. RELAP/SCDAPSIM/MOD3.2 treats axial and radial spreads by repeated cycles of melting, flowing and freezing. Bottom crusts can be supported by intact fuel rods. By these more realistic RELAP/SCDAPSIM/MOD3.2 models, MAAP4.03 could be supported maintaining conservatism. (author)

  1. Implementation of the thermal-hydraulic transient analysis code RELAP4/MOD5 and MOD6 on the FACOM 230/75 computer system

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Ishigai, Takahiro; Kumakura, Toshimasa; Naraoka, Ken-itsu

    1979-03-01

    Development efforts have continued on the extensively used LOCA analysis code RELAP-4, as seen in its history; that is, from the prototype version MOD2 to the latest one MOD6 which is capable of one-through calculations from blowdown to reflood phase of PWR-LOCA. Many improvements and refinements of the models have enlarged the scopes and extents of phenomena to treat. Correspondingly the size of program has increased version to version, and special programming techniques have continuously been introduced to manage the program within limited capacity of core memory. For example, the Dynamic Storage Allocation of MOD5 and the PRELOAD Preprocessor newly incorporated in MOD6 are those designed for the CDC computer with relatively small core size. Described are these programming techniques in detail and experiences on implementation of the codes on FACOM 230/75, together with some results of confirmatory calculations. (author)

  2. RELAP4/MOD6 analysis of forced- and gravity-feed reflood tests

    International Nuclear Information System (INIS)

    Chen, T.H.; Fletcher, C.D.

    1980-01-01

    The RELAP4/MOD6 computer code is used for the analysis of the reactor core heat transfer during the reflooding phase of a postulated loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR). The code requires the user to specify input parameters for the reflood heat transfer models. Results of previous comparisons of code calculations with experimental data have indicated no single selection of input parameters is adequate for a spectrum of tests and test facilities. This paper presents the development of revised quidelines and assesses the effect of those modifications on RELAP4/MOD6 data comparisons using previously analyzed reflood experiments. The paper also presents an assessment of the revised guidelines and the original guidelines against experimental data significantly different from previously analyzed tests

  3. Visualization of RELAP5-3D best estimate code

    International Nuclear Information System (INIS)

    Mesina, G.L.

    2004-01-01

    The Idaho National Engineering Laboratory has developed a number of nuclear plant analysis codes such as RELAP5-3D, SCDAP/RELAP5-3D, and FLUENT/RELAP5-3D that have multi-dimensional modeling capability. The output of these codes is very difficult to analyze without the aid of visualization tools. The RELAP5-3D Graphical User Interface (RGUI) displays these calculations on plant images, functional diagrams, graphs, and by other means. These representations of the data enhance the analysts' ability to recognize plant behavior visually and reduce the difficulty of analyzing complex three-dimensional models. This paper describes the Graphical User Interface system for the RELAP5-3D suite of Best Estimate codes. The uses of the Graphical User Interface are illustrated. Examples of user problems solved by use of this interface are given. (author)

  4. Thermal hydraulic-severe accident code interfaces for SCDAP/RELAP5/MOD3.2

    Energy Technology Data Exchange (ETDEWEB)

    Coryell, E.W.; Siefken, L.J.; Harvego, E.A. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1997-07-01

    The SCDAP/RELAP5 computer code is designed to describe the overall reactor coolant system thermal-hydraulic response, core damage progression, and fission product release during severe accidents. The code is being developed at the Idaho National Engineering Laboratory under the primary sponsorship of the Office of Nuclear Regulatory Research of the U.S. Nuclear Regulatory Commission. The code is the result of merging the RELAP5, SCDAP, and COUPLE codes. The RELAP5 portion of the code calculates the overall reactor coolant system, thermal-hydraulics, and associated reactor system responses. The SCDAP portion of the code describes the response of the core and associated vessel structures. The COUPLE portion of the code describes response of lower plenum structures and debris and the failure of the lower head. The code uses a modular approach with the overall structure, input/output processing, and data structures following the pattern established for RELAP5. The code uses a building block approach to allow the code user to easily represent a wide variety of systems and conditions through a powerful input processor. The user can represent a wide variety of experiments or reactor designs by selecting fuel rods and other assembly structures from a range of representative core component models, and arrange them in a variety of patterns within the thermalhydraulic network. The COUPLE portion of the code uses two-dimensional representations of the lower plenum structures and debris beds. The flow of information between the different portions of the code occurs at each system level time step advancement. The RELAP5 portion of the code describes the fluid transport around the system. These fluid conditions are used as thermal and mass transport boundary conditions for the SCDAP and COUPLE structures and debris beds.

  5. Thermal hydraulic-severe accident code interfaces for SCDAP/RELAP5/MOD3.2

    International Nuclear Information System (INIS)

    Coryell, E.W.; Siefken, L.J.; Harvego, E.A.

    1997-01-01

    The SCDAP/RELAP5 computer code is designed to describe the overall reactor coolant system thermal-hydraulic response, core damage progression, and fission product release during severe accidents. The code is being developed at the Idaho National Engineering Laboratory under the primary sponsorship of the Office of Nuclear Regulatory Research of the U.S. Nuclear Regulatory Commission. The code is the result of merging the RELAP5, SCDAP, and COUPLE codes. The RELAP5 portion of the code calculates the overall reactor coolant system, thermal-hydraulics, and associated reactor system responses. The SCDAP portion of the code describes the response of the core and associated vessel structures. The COUPLE portion of the code describes response of lower plenum structures and debris and the failure of the lower head. The code uses a modular approach with the overall structure, input/output processing, and data structures following the pattern established for RELAP5. The code uses a building block approach to allow the code user to easily represent a wide variety of systems and conditions through a powerful input processor. The user can represent a wide variety of experiments or reactor designs by selecting fuel rods and other assembly structures from a range of representative core component models, and arrange them in a variety of patterns within the thermalhydraulic network. The COUPLE portion of the code uses two-dimensional representations of the lower plenum structures and debris beds. The flow of information between the different portions of the code occurs at each system level time step advancement. The RELAP5 portion of the code describes the fluid transport around the system. These fluid conditions are used as thermal and mass transport boundary conditions for the SCDAP and COUPLE structures and debris beds

  6. Analysis of the General Electric Company swell tests with RELAP4/MOD7

    International Nuclear Information System (INIS)

    Fischer, S.R.; Hendrix, C.E.

    1979-01-01

    The RELAP4/MOD7 nuclear reactor transient analysis code, presently being developed by EG and G Idaho, Inc., will incorporate several significant improvements over earlier versions of RELAP4. As part of the development of RELAP4/MOD7, a thorough assessment of the capability of the code to simulate water reactor LOCA phenomena is being made. This assessment is accomplished in part by comparing results from code calculations with test data from experimental facilities. Simulations of the General Electric Company (GE) level swell tests were performed as part of the code checkout. In these tests, a pressurized vessel partially filled with nearly saturated water was blown down through a simulated break located near the top of the vessel. Comparison of RELAP4 calculations with data from these experiments indicates that the code has the capability to model the unequal phase velocity flow and resulting density gradients that might occur in a BWR steam line break transient. Comparisons of RELAP4 calculations with data from two level swell experiments are presented

  7. Investigation of station blackout scenario in VVER440/v230 with RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Gencheva, Rositsa Veselinova, E-mail: roseh@mail.bg; Stefanova, Antoaneta Emilova, E-mail: antoanet@inrne.bas.bg; Groudev, Pavlin Petkov, E-mail: pavlinpg@inrne.bas.bg

    2015-12-15

    Highlights: • We have modeled SBO in VVER440. • RELAP5/MOD3 computer code has been used. • Base case calculation has been done. • Fail case calculation has been done. • Operator and alternative operator actions have been investigated. - Abstract: During the development of symptom-based emergency operating procedures (SB-EOPs) for VVER440/v230 units at Kozloduy Nuclear Power Plant (NPP) a number of analyses have been performed using the RELAP5/MOD3 (Carlson et al., 1990). Some of them investigate the response of VVER440/v230 during the station blackout (SBO). The main purpose of the analyses presented in this paper is to identify the behavior of important VVER440 parameters in case of total station blackout. The RELAP5/MOD3 has been used to simulate the SBO in VVER440 NPP model (Fletcher and Schultz, 1995). This model was developed at the Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences (INRNE-BAS), Sofia, for analyses of operational occurrences, abnormal events and design based scenarios. The model provides a significant analytical capability for specialists working in the field of NPP safety.

  8. Development and application of the PCRELAP5 - Data Calculation Program for RELAP 5 Code

    International Nuclear Information System (INIS)

    Silvestre, Larissa J.B.; Sabundjian, Gaianê

    2017-01-01

    Nuclear accidents in the world led to the establishment of rigorous criteria and requirements for nuclear power plant operations by the international regulatory bodies. By using specific computer programs, simulations of various accidents and transients likely to occur at any nuclear power plant are required for certifying and licensing a nuclear power plant. Some sophisticated computational tools have been used such as the Reactor Excursion and Leak Analysis Program (RELAP5), which is the most widely used code for the thermo-hydraulic analysis of accidents and transients in nuclear reactors in Brazil and worldwide. A major difficulty in the simulation by using RELAP5 code is the amount of information required for the simulation of thermal-hydraulic accidents or transients. Thus, for those calculations performance and preparation of RELAP5 input data, a friendly mathematical preprocessor was designed. The Visual Basic for Application (VBA) for Microsoft Excel demonstrated to be an effective tool to perform a number of tasks in the development of the program. In order to meet the needs of RELAP5 users, the RELAP5 Calculation Program (Programa de Cálculo do RELAP5 – PCRELAP5) was designed. The components of the code were codified; all entry cards including the optional cards of each one have been programmed. An English version for PCRELAP5 was provided. Furthermore, a friendly design was developed in order to minimize the time of preparation of input data and errors committed by users. The final version of this preprocessor was successfully applied for Safety Injection System (SIS) of Angra-2. (author)

  9. Development and application of the PCRELAP5 - Data Calculation Program for RELAP 5 Code

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre, Larissa J.B.; Sabundjian, Gaianê, E-mail: larissajbs@usp.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Nuclear accidents in the world led to the establishment of rigorous criteria and requirements for nuclear power plant operations by the international regulatory bodies. By using specific computer programs, simulations of various accidents and transients likely to occur at any nuclear power plant are required for certifying and licensing a nuclear power plant. Some sophisticated computational tools have been used such as the Reactor Excursion and Leak Analysis Program (RELAP5), which is the most widely used code for the thermo-hydraulic analysis of accidents and transients in nuclear reactors in Brazil and worldwide. A major difficulty in the simulation by using RELAP5 code is the amount of information required for the simulation of thermal-hydraulic accidents or transients. Thus, for those calculations performance and preparation of RELAP5 input data, a friendly mathematical preprocessor was designed. The Visual Basic for Application (VBA) for Microsoft Excel demonstrated to be an effective tool to perform a number of tasks in the development of the program. In order to meet the needs of RELAP5 users, the RELAP5 Calculation Program (Programa de Cálculo do RELAP5 – PCRELAP5) was designed. The components of the code were codified; all entry cards including the optional cards of each one have been programmed. An English version for PCRELAP5 was provided. Furthermore, a friendly design was developed in order to minimize the time of preparation of input data and errors committed by users. The final version of this preprocessor was successfully applied for Safety Injection System (SIS) of Angra-2. (author)

  10. Analysis of RELAP/SCDAPSIM/MOD3.2 Computer Code using QUENCH Experiments

    International Nuclear Information System (INIS)

    Honaiser, Eduardo; Anghaie, Samim

    2004-01-01

    The experiments QUENCH-01/06 were modelled using RELAP5/SCDAPSIM MOD3.2(bd) computer code. The results obtained from these models were compared to the experimental data to evaluate the code performance. The experiments were performed in the Forschungszentrum Karlsruhe (FZK), Germany. The objective of the experimental program was the investigation of the core behaviour during a severe accident, focusing on rod claddings overheat due to zirconium oxidation at high temperatures and due to the strong thermal gradient developed when the nuclear reactor core is flooded as part of an accident management measure. Temperatures histories and hydrogen production were compared. Molecular hydrogen is a product of the oxidation reaction, serving as a parameter to measure the oxidation reaction. After some model adjustments, good predictions were possible. The temperatures and the hydrogen production parameters stayed, most of the transient time, inside the uncertainty envelop. (authors)

  11. Simulation of small break loss of coolant accident using relap 5/ MOD 2 computer code

    International Nuclear Information System (INIS)

    Megahed, M.M.

    1992-01-01

    An assessment of relap 5 / MOD 2/Cycle 36.05 best estimate computer code capabilities in predicting the thermohydraulic response of a PWR following a small break loss of coolant accident is presented. The experimental data base for the evaluation is the results of Test S-N H-3 performed in the semi scale MOD-2 c Test facility which modeled a 0.5% small break loss of coolant accident with an accompanying failure of the high pressure injection emergency core cooling system. A conclusion was reached that the code is capable of making small break loss of coolant accident calculations efficiently. However, some of the small break loss of coolant accident related phenomena were not properly predicted by the code, suggesting a need for code improvement.9 fig., 3 tab

  12. Comparative analysis of the results obtained by computer code ASTEC V2 and RELAP 5.3.2 for small leak ID 80 for VVER 1000

    International Nuclear Information System (INIS)

    Atanasova, B.; Grudev, P.

    2011-01-01

    The purpose of this report is to present the results obtained by simulation and subsequent analysis of emergency mode for small leak with ID 80 for WWER 1000/B320 - Kozloduy NPP Units 5 and 6. Calculations were performed with the ASTEC v2 computer code used for calculation of severe accident, which was designed by French and German groups - IRSN and GRS. Integral RELAP5 computer code is used as a reference for comparison of results. The analyzes are focused on the processes occurring in reactor internals phase of emergency mode with significant core damage. The main thermohydraulic parameters, start of reactor core degradation and subsequent fuel relocalization till reactor vessel failure are evaluated in the analysis. RELAP5 computer code is used as a reference code to compare the results obtained till early core degradation that occurs after core stripping and excising of fuel temperature above 1200 0 C

  13. Lesson learned from the application to LOBI tests of CATHARE and RELAP5 codes

    International Nuclear Information System (INIS)

    Ambrosini, W.; D'Auria, F.; Galassi, G.M.

    1992-01-01

    The Dipt. di Costruzioni Meccaniche e Nucleari has participated to the LOBI project since its very beginning, contributing to almost all the international activities in this field, such as task group meetings, International Standards Problems, Seminars, etc. System codes like RELAP4/MOD6, RELAP5/MOD1, RELAP5/MOD1-EUR, RELAP5/MOD2, CATHARE 1 and CATHARE 2 were applied to the design and post test evaluation of a wide series of both LOBI/MOD1 and LOBI/MOD2 experiments, including Large Break LOCAs, Small and Intermediate Break LOCAs, long lasting transients and characterization tests. The LOBI data base demonstrated its usefulness in assessing capabilities and limitations of these codes and in qualifying a code use strategy. (author)

  14. Evaluation of void fraction measurements from DADINE experience using RELAP4/MOD5 code

    International Nuclear Information System (INIS)

    Borges, R.C.; Freitas, R.L.

    1989-01-01

    The DADINE experiment measures the axial evolution of the void fraction by neutronic diffusion in two-phase flow in the wet regions of a pressurized water reactor in accident conditions. Since the theoretical/experimental confrontation is important for code evaluation, this paper presents the simulation with the RELAP4/MOD5 Code of the void fractions results obtained in the DADINE Experiment, that showed some deviation probably associated with the existing models in Code, special attention in the way of stablishing the two-phase flow and the no characterization of the differents flow regimes related with the void fractions. (author) [pt

  15. PCRELAP5: data calculation program for RELAP 5 code; PCRELAP5: programa de calculo dos dados de entrada para o codigo RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre, Larissa Jacome Barros

    2016-07-01

    Nuclear accidents in the world led to the establishment of rigorous criteria and requirements for nuclear power plant operations by the international regulatory bodies. By using specific computer programs, simulations of various accidents and transients likely to occur at any nuclear power plant are required for certifying and licensing a nuclear power plant. Based on this scenario, some sophisticated computational tools have been used such as the Reactor Excursion and Leak Analysis Program (RELAP5), which is the most widely used code for the thermo-hydraulic analysis of accidents and transients in nuclear reactors in Brazil and worldwide. A major difficulty in the simulation by using RELAP5 code is the amount of information required for the simulation of thermal-hydraulic accidents or transients. The preparation of the input data requires a great number of mathematical operations to calculate the geometry of the components. Thus, for those calculations performance and preparation of RELAP5 input data, a friendly mathematical preprocessor was designed. The Visual Basic for Application (VBA) for Microsoft Excel demonstrated to be an effective tool to perform a number of tasks in the development of the program. In order to meet the needs of RELAP5 users, the RELAP5 Calculation Program (Programa de Calculo do RELAP5 - PCRELAP5) was designed. The components of the code were codified; all entry cards including the optional cards of each one have been programmed. In addition, an English version for PCRELAP5 was provided. Furthermore, a friendly design was developed in order to minimize the time of preparation of input data and errors committed by users. In this work, the final version of this preprocessor was successfully applied for Safety Injection System (SIS) of Angra 2. (author)

  16. Manometer Behavior Analysis using CATHENA, RELAP and GOTHIC Codes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yang Hoon; Han, Kee Soo; Moon, Bok Ja; Jang, Misuk [Nuclear Engineering Service and Solution Co. Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    In this presentation, simple thermal hydraulic behavior is analyzed using three codes to show the possibility of using alternative codes. We established three models of simple u-tube manometer using three different codes. CATHENA (Canadian Algorithm for Thermal hydraulic Network Analysis), RELAP (Reactor Excursion and Leak Analysis Program), GOTHIC (Generation of Thermal Hydraulic Information for Containments) are used for this analysis. CATHENA and RELAP are widely used codes for the analysis of system behavior of CANDU and PWR. And GOTHIC code also has been widely used for the analysis of thermal hydraulic behavior in the containment system. In this paper, the internal behavior of u-tube manometer was analyzed using 3 codes, CATHENA, RELAP and GOTHIC. The general transient behavior is similar among 3 codes. However, the behavior simulated using GOTHIC shows some different trend compared with the results from the other 2 codes at the end of the transient. It would be resulted from the use of different physical model in GOTHIC, which is specialized for the multi-phase thermal hydraulic behavior analysis of containment system unlike the other two codes.

  17. International Code Assessment and Applications Program: Summary of code assessment studies concerning RELAP5/MOD2, RELAP5/MOD3, and TRAC-B

    International Nuclear Information System (INIS)

    Schultz, R.R.

    1993-12-01

    Members of the International Code Assessment Program (ICAP) have assessed the US Nuclear Regulatory Commission (USNRC) advanced thermal-hydraulic codes over the past few years in a concerted effort to identify deficiencies, to define user guidelines, and to determine the state of each code. The results of sixty-two code assessment reviews, conducted at INEL, are summarized. Code deficiencies are discussed and user recommended nodalizations investigated during the course of conducting the assessment studies and reviews are listed. All the work that is summarized was done using the RELAP5/MOD2, RELAP5/MOD3, and TRAC-B codes

  18. Analysis of the reflood experiment by RELAP5/MOD2 code

    International Nuclear Information System (INIS)

    Prosek, A.; Stritar, A.

    1990-01-01

    The analysis of the reflood experiment on the test rig Achilles has been performed. The analysis has been done by the RELAP5/MOD2 code after the results of the experiment had been released. The experiment has been analyze in several other laboratories around the world. Our results are comparable to other analyses and are in the range of RELAP5/MOD2 capabilities. Two analyses have been done: the core only and the complete system. Computed clad temperatures in the first case are higher than measured, in the second case they are somewhat lower. (author)

  19. Development and validation of gui based input file generation code for relap

    International Nuclear Information System (INIS)

    Anwar, M.M.; Khan, A.A.; Chughati, I.R.; Chaudri, K.S.; Inyat, M.H.; Hayat, T.

    2009-01-01

    Reactor Excursion and Leak Analysis Program (RELAP) is a widely acceptable computer code for thermal hydraulics modeling of Nuclear Power Plants. It calculates thermal- hydraulic transients in water-cooled nuclear reactors by solving approximations to the one-dimensional, two-phase equations of hydraulics in an arbitrarily connected system of nodes. However, the preparation of input file and subsequent analysis of results in this code is a tedious task. The development of a Graphical User Interface (GUI) for preparation of the input file for RELAP-5 is done with the validation of GUI generated Input File. The GUI is developed in Microsoft Visual Studio using Visual C Sharp (C) as programming language. The Nodalization diagram is drawn graphically and the program contains various component forms along with the starting data form, which are launched for properties assignment to generate Input File Cards serving as GUI for the user. The GUI is provided with Open / Save function to store and recall the Nodalization diagram along with Components' properties. The GUI generated Input File is validated for several case studies and individual component cards are compared with the originally required format. The generated Input File of RELAP is found consistent with the requirement of RELAP. The GUI provided a useful platform for simulating complex hydrodynamic problems efficiently with RELAP. (author)

  20. RELAP-7 Closure Correlations

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Berry, R. A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, R. C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, H. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hansel, J. E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Sharpe, J. P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Johns, Russell C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-04-01

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The code is based on the INL’s modern scientific software development framework, MOOSE (Multi-Physics Object Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5’s and TRACE’s capabilities and extends their analysis capabilities for all reactor system simulation scenarios. The RELAP-7 code utilizes the well-posed 7-equation two-phase flow model for compressible two-phase flow. Closure models used in the TRACE code has been reviewed and selected to reflect the progress made during the past decades and provide a basis for the colure correlations implemented in the RELAP-7 code. This document provides a summary on the closure correlations that are currently implemented in the RELAP-7 code. The closure correlations include sub-grid models that describe interactions between the fluids and the flow channel, and interactions between the two phases.

  1. Use of moving heat conductor mesh to perform reflood calculations with RELAP4/MOD6

    International Nuclear Information System (INIS)

    Fischer, S.R.; Ellis, L.V.; Chen, Y.S.

    1979-01-01

    RELAP4 is a computer code which can be used for the transient thermal hydraulic analysis of light water reactors and related systems. RELAP4/MOD6 includes many new analytical models which were developed primarily for the analysis of the reflood phase of a PWR loss-of-coolant accident (LOCA) transient. The key feature forming the basis for the MOD6 reflood calculation is a unique moving finite differenced heat conductor. The development and application of the moving heat conductor mesh for use in reflood analysis are described

  2. Developmental assessment of the SCDAP/RELAP5 code

    International Nuclear Information System (INIS)

    Harvego, E.A.; Slefken, L.J.; Coryell, E.W.

    1997-01-01

    The development and assessment of the late-phase damage progression models in the current version (designated MOD3.2) of the SCDAP/RELAP5 code are described. The SCDAP/RELAP5 code is being developed at the Idaho National Engineering and Environmental Laboratory under the primary sponsorship of the US Nuclear Regulatory Commission (NRC) to provide best-estimate transient simulations of light water reactor coolant systems (RCS) during severe accident conditions. Recent modeling improvements made to the MOD3.2 version of the code include (1) molten pool formation and heat up, including the transient start-up of natural circulation heat transfer, (2) in-core molten pool thermal-mechanical crust failure, (3) the melting and relocation of upper plenum structures, and (4) improvements in the modeling of lower plenum debris behavior and the potential for failure of the lower head. Finally, to eliminate abrupt transitions between core damage states and provide more realistic predictions of late phase accident progression phenomena, a transition smoothing methodology was developed and implemented that results in the calculation of a gradual transition from an intact core geometry through the different core damage states leading to molten pool formation. A wide range of experiments and modeling tools were used to assess the capabilities of MOD3.2. The results of the SCDAP/RELAP5/MOD3.2 assessment indicate that modeling improvements have significantly enhanced the code capabilities and performance in several areas compared to the earlier code version. New models for transition smoothing between core damage states, and modeling improvements/additions for cladding oxide failure, molten pool behavior, and molten pool crust failure have significantly improved the code usability for a wide range of applications and have significantly improved the prediction of hydrogen production, molten pool melt mass and core melt relocation time

  3. Uncertainty analysis of the 35% reactor inlet header break in a CANDU 6 reactor using RELAP/SCDAPSIM/MOD4.0 with integrated uncertainty analysis option

    International Nuclear Information System (INIS)

    Dupleac, D.; Perez, M.; Reventos, F.; Allison, C.

    2011-01-01

    The RELAP/SCDAPSIM/MOD4.0 code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed as part of an international nuclear technology Software Development and Training Program (SDTP). RELAP/SCDAPSIM/MOD4.0, which is the first version of RELAP5 completely rewritten to FORTRAN 90/95/2000 standards, uses the publicly available RELAP5 and SCDAP models in combination with (a) advanced programming and numerical techniques, (b) advanced SDTP-member-developed models for LWR, HWR, and research reactor analysis, and (c) a variety of other member-developed computational packages. One such computational package is an integrated uncertainty analysis (IUA) package being developed jointly by the Technical University of Catalonia (UPC) and Innovative Systems Software (ISS). RELAP/SCDAPSIM/MOD4.0(IUA) follows the input-propagation approach using probability distribution functions to define the uncertainty of the input parameters. The main steps for this type of methodologies, often referred as to statistical approaches or Wilks’ methods, are the ones that follow: 1. Selection of the plant; 2. Selection of the scenario; 3. Selection of the safety criteria; 4. Identification and ranking of the relevant phenomena based on the safety criteria; 5. Selection of the appropriate code parameters to represent those phenomena; 6. Association of uncertainty by means of Probability Distribution Functions (PDFs) for each selected parameter; 7. Random sampling of the selected parameters according to its PDF and performing multiple computer runs to obtain uncertainty bands with a certain percentile and confidence level; 8. Processing the results of the multiple computer runs to estimate the uncertainty bands for the computed quantities associated with the selected safety criteria. RELAP/SCDAPSIM/MOD4.0(IUA) calculates the number of required code runs given the desired percentile and confidence level, performs the sampling process for the

  4. Uncertainty analysis of the 35% reactor inlet header break in a CANDU 6 reactor using RELAP/SCDAPSIM/MOD4.0 with integrated uncertainty analysis option

    Energy Technology Data Exchange (ETDEWEB)

    Dupleac, D., E-mail: danieldu@cne.pub.ro [Politehnica Univ. of Bucharest (Romania); Perez, M.; Reventos, F., E-mail: marina.perez@upc.edu, E-mail: francesc.reventos@upc.edu [Technical Univ. of Catalonia (Spain); Allison, C., E-mail: iss@cableone.net [Innovative Systems Software (United States)

    2011-07-01

    The RELAP/SCDAPSIM/MOD4.0 code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed as part of an international nuclear technology Software Development and Training Program (SDTP). RELAP/SCDAPSIM/MOD4.0, which is the first version of RELAP5 completely rewritten to FORTRAN 90/95/2000 standards, uses the publicly available RELAP5 and SCDAP models in combination with (a) advanced programming and numerical techniques, (b) advanced SDTP-member-developed models for LWR, HWR, and research reactor analysis, and (c) a variety of other member-developed computational packages. One such computational package is an integrated uncertainty analysis (IUA) package being developed jointly by the Technical University of Catalonia (UPC) and Innovative Systems Software (ISS). RELAP/SCDAPSIM/MOD4.0(IUA) follows the input-propagation approach using probability distribution functions to define the uncertainty of the input parameters. The main steps for this type of methodologies, often referred as to statistical approaches or Wilks’ methods, are the ones that follow: 1. Selection of the plant; 2. Selection of the scenario; 3. Selection of the safety criteria; 4. Identification and ranking of the relevant phenomena based on the safety criteria; 5. Selection of the appropriate code parameters to represent those phenomena; 6. Association of uncertainty by means of Probability Distribution Functions (PDFs) for each selected parameter; 7. Random sampling of the selected parameters according to its PDF and performing multiple computer runs to obtain uncertainty bands with a certain percentile and confidence level; 8. Processing the results of the multiple computer runs to estimate the uncertainty bands for the computed quantities associated with the selected safety criteria. RELAP/SCDAPSIM/MOD4.0(IUA) calculates the number of required code runs given the desired percentile and confidence level, performs the sampling process for the

  5. Verification of LOCA/ECCS analysis codes ALARM-B2 and THYDE-B1 by comparison with RELAP4/MOD6/U4/J3

    International Nuclear Information System (INIS)

    Shimizu, Takashi

    1982-08-01

    For a verification study of ALARM-B2 code and THYDE-B1 code which are the component of the JAERI code system for evaluation of BWR ECCS performance, calculations for typical small and large break LOCA in BWR were done, and compared with those by RELAP4/MOD6/U4/J3 code. This report describes the influences of differences between the analytical models incorporated in the individual code and the problems identified by this verification study. (author)

  6. Analysis of steam generator loss-of-feedwater experiments with APROS and RELAP5/MOD3.1 computer codes

    Energy Technology Data Exchange (ETDEWEB)

    Virtanen, E.; Haapalehto, T. [Lappeenranta Univ. of Technology, Lappeenranta (Finland); Kouhia, J. [VTT Energy, Nuclear Energy, Lappeenranta (Finland)

    1995-09-01

    Three experiments were conducted to study the behavior of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes to that the results may be compared. Only the steam generator was modelled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heat exchange tube bundle than was measured in the experiments.

  7. RELAP5-3D Code for Supercritical-Pressure Light-Water-Cooled Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Riemke, Richard Allan; Davis, Cliff Bybee; Schultz, Richard Raphael

    2003-04-01

    The RELAP5-3D computer program has been improved for analysis of supercritical-pressure, light-water-cooled reactors. Several code modifications were implemented to correct code execution failures. Changes were made to the steam table generation, steam table interpolation, metastable states, interfacial heat transfer coefficients, and transport properties (viscosity and thermal conductivity). The code modifications now allow the code to run slow transients above the critical pressure as well as blowdown transients (modified Edwards pipe and modified existing pressurized water reactor model) that pass near the critical point.

  8. Assessment of the RELAP4/MOD6 thermal-hydraulic transient code for PWR experimental applications. Addendum. Analyses completed and reported in FY 1979. Interim report

    International Nuclear Information System (INIS)

    1979-09-01

    The results of three subtasks that complete the assessment of the RELAP4/MOD6 computer code are reported. These subtasks constitute the remainder of a broadly scoped assessment matrix defined and described in detail in a previously published document. The specific subtasks provide comparisons of code calculations with experimental results from core blowdown and critical-flow separate-effects experiments and from an integral systems-effects loss-of-coolant experiment. The basic emphasis of the comparisons is in the presentation of the study results in error form suitable for statistical analysis

  9. Analysis of steam generator loss-of-feedwater experiments with APROS and RELAP5/MOD3.1 computer codes

    International Nuclear Information System (INIS)

    Virtanen, E.; Haapalehto, T.; Kouhia, J.

    1997-01-01

    Three experiments were conducted to study the behaviour of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes so that the results may be compared. Only the steam generator was modeled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heat exchange tube bundle than was measured in the experiments. (orig.)

  10. Review of the SCDAP/RELAP5/MOD3.1 code structure and core T/H model before core damage

    International Nuclear Information System (INIS)

    Kim, See Darl; Kim, Dong Ha

    1998-04-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during a severe accident. The code is being developed at the INEL under the primary sponsorship of the Office of Nuclear Regulatory Research of the U.S. NRC. As The current time, the SCDAP/RELAP5/MOD3.1 code is the result of merging the RELAP5/MOD3 and SCDAP models. The code models the coupled behavior of the reactor coolant system, core, fission product released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. Major purpose of the report is to provide information about the characteristics of SCDAP/RELAP5/MOD3.1 core T/H models for an integrated severe accident computer code being developed under the mid/long-term project. This report analyzes the overall code structure which consists of the input processor, transient controller, and plot file handler. The basic governing equations to simulate the thermohydraulics of the primary system are also described. As the focus is currently concentrated in the core, core nodalization parameters of the intact geometry and the phenomenological subroutines for the damaged core are summarized for the future usage. In addition, the numerical approach for the heat conduction model is investigated along with heat convection model. These studies could provide a foundation for input preparation and model improvement. (author). 6 refs., 3 tabs., 4 figs

  11. RELAP5/MOD2 code modifications to obtain better predictions for the once-through steam generator

    International Nuclear Information System (INIS)

    Blanchat, T.; Hassan, Y.

    1989-01-01

    The steam generator is a major component in pressurized water reactors. Predicting the response of a steam generator during both steady-state and transient conditions is essential in studying the thermal-hydraulic behavior of a nuclear reactor coolant system. Therefore, many analytical and experimental efforts have been performed to investigate the thermal-hydraulic behavior of the steam generators during operational and accident transients. The objective of this study is to predict the behavior of the secondary side of the once-through steam generator (OTSG) using the RELAP5/MOD2 computer code. Steady-state conditions were predicted with the current version of the RELAP5/MOD2 code and compared with experimental plant data. The code predictions consistently underpredict the degree of superheat. A new interface friction model has been implemented in a modified version of RELAP5/MOD2. This modification, along with changes to the flow regime transition criteria and the heat transfer correlations, correctly predicts the degree of superheat and matches plant data

  12. Independent assessment of TRAC-PD2 and RELAP5/MOD1 codes at BNL in FY 1981

    International Nuclear Information System (INIS)

    Saha, P.; Jo, J.H.; Neymotin, L.; Rohatgi, U.S.; Slovik, G.

    1982-12-01

    This report documents the independent assessment calculations performed with the TRAC-PD2 and RELAP/MOD1 codes at Brookhaven National Laboratory (BNL) during Fiscal Year 1981. A large variety of separate-effects experiments dealing with (1) steady-state and transient critical flow, (2) level swell, (3) flooding and entrainment, (4) steady-state flow boiling, (5) integral economizer once-through steam generator (IEOTSG) performance, (6) bottom reflood, and (7) two-dimensional phase separation of two-phase mixtures were simulated with TRAC-PD2. In addition, the early part of an overcooling transient which occurred at the Rancho Seco nuclear power plant on March 20, 1978 was also computed with an updated version of TRAC-PD2. Three separate-effects tests dealing with (1) transient critical flow, (2) steady-state flow boiling, and (3) IEOTSG performance were also simulated with RELAP5/MOD1 code. Comparisons between the code predictions and the test data are presented

  13. RELAP-7 Level 2 Milestone Report: Demonstration of a Steady State Single Phase PWR Simulation with RELAP-7

    International Nuclear Information System (INIS)

    Andrs, David; Berry, Ray; Gaston, Derek; Martineau, Richard; Peterson, John; Zhang, Hongbin; Zhao, Haihua; Zou, Ling

    2012-01-01

    evolve with time. RELAP-7 is a MOOSE-based application. MOOSE (Multiphysics Object-Oriented Simulation Environment) is a framework for solving computational engineering problems in a well-planned, managed, and coordinated way. By leveraging millions of lines of open source software packages, such as PETSC (a nonlinear solver developed at Argonne National Laboratory) and LibMesh (a Finite Element Analysis package developed at University of Texas), MOOSE significantly reduces the expense and time required to develop new applications. Numerical integration methods and mesh management for parallel computation are provided by MOOSE. Therefore RELAP-7 code developers only need to focus on physics and user experiences. By using the MOOSE development environment, RELAP-7 code is developed by following the same modern software design paradigms used for other MOOSE development efforts. There are currently over 20 different MOOSE based applications ranging from 3-D transient neutron transport, detailed 3-D transient fuel performance analysis, to long-term material aging. Multi-physics and multiple dimensional analyses capabilities can be obtained by coupling RELAP-7 and other MOOSE based applications and by leveraging with capabilities developed by other DOE programs. This allows restricting the focus of RELAP-7 to systems analysis-type simulations and gives priority to retain and significantly extend RELAP5's capabilities.

  14. Simulation of accident and restrained transients in PWR nuclear power plant with RELAP 5/MOD 1 computer code

    International Nuclear Information System (INIS)

    Silva Filho, E.

    1986-01-01

    The computer code RELAP5/MOD1 has been utilized to investigate the thermal-hydraulic behaviour of a standard 1300 Mwe pressurized water reactor plant of the KWU design during a station blackout and during a loss-of-coolant accident involving 2% break in the cross-sectional area the cold leg in one of the four loops and located between the pump and the reactor pressure vessel. During the simulations the reactor scram system and the emergency coolant system were considered inactive. (Author) [pt

  15. Validation of system codes RELAP5 and SPECTRA for natural convection boiling in narrow channels

    Energy Technology Data Exchange (ETDEWEB)

    Stempniewicz, M.M., E-mail: stempniewicz@nrg.eu; Slootman, M.L.F.; Wiersema, H.T.

    2016-10-15

    Highlights: • Computer codes RELAP5/Mod3.3 and SPECTRA 3.61 validated for boiling in narrow channels. • Validated codes can be used for LOCA analyses in research reactors. • Code validation based on natural convection boiling in narrow channels experiments. - Abstract: Safety analyses of LOCA scenarios in nuclear power plants are performed with so called thermal–hydraulic system codes, such as RELAP5. Such codes are validated for typical fuel geometries applied in nuclear power plants. The question considered by this article is if the codes can be applied for LOCA analyses in research reactors, in particular exceeding CHF in very narrow channels. In order to answer this question, validation calculations were performed with two thermal–hydraulic system codes: RELAP and SPECTRA. The validation was based on natural convection boiling in narrow channels experiments, performed by Prof. Monde et al. in the years 1990–2000. In total 42 vertical tube and annulus experiments were simulated with both codes. A good agreement of the calculated values with the measured data was observed. The main conclusions are: • The computer codes RELAP5/Mod 3.3 (US NRC version) and SPECTRA 3.61 have been validated for natural convection boiling in narrow channels using experiments of Monde. The dimensions applied in the experiments were performed for a range that covers the values observed in typical research reactors. Therefore it is concluded that both codes are validated and can be used for LOCA analyses in research reactors, including natural convection boiling. The applicability range of the present validation is: hydraulic diameters of 1.1 ⩽ D{sub hyd} ⩽ 9.0 mm, heated lengths of 0.1 ⩽ L ⩽ 1.0 m, pressures of 0.10 ⩽ P ⩽ 0.99 MPa. In most calculations the burnout was predicted to occur at lower power than that observed in the experiments. In several cases the burnout was observed at higher power. The overprediction was not larger than 16% in RELAP and 15% in

  16. Implementation of an enlarged model of the safety valves and relief in the plant integral model for the code RELAP/SCDAPSIM

    International Nuclear Information System (INIS)

    Amador G, R.; Ortiz V, J.; Castillo D, R.; Hernandez L, E. J.; Galeana R, J. C.; Gutierrez, V. H.

    2013-10-01

    The present work refers to the implementation of a new model on the logic of the safety valves and relief in the integral model of the Nuclear Power Plant of Laguna Verde of the thermal-hydraulic compute code RELAP/SCDAPSIM Mod. 3.4. The new model was developed with the compute package SIMULINK-MATLAB and contemplates all the operation options of the safety valves and relief, besides including the availability options of the valves in all the operation ways and of blockage in the ways of relief and low-low. The implementation means the elimination of the old model of the safety valves and to analyze the group of logical variables, of discharge and available control systems to associate them to the model of package SIMULINK-MATLAB. The implementation has been practically transparent and 27 cases corresponding to a turbine discharge were analyzed with the code RELAP/SCDAPSIM Mod. 3.4. The results were satisfactory. (Author)

  17. Vectorization of LWR transient analysis code RELAP5/MOD1 and its effect

    International Nuclear Information System (INIS)

    Ishiguro, Misako; Harada, Hiroo; Shinozawa, Naohisa; Naraoka, Ken-itsu

    1985-03-01

    The RELAP5/MOD1 is a large thermal-hydraulic code to analyze LWR LOCA and non-LOCA transients. The code originally was designed for use on a CDC Cyber-176. This report documents vectorization of the RELAP5/MOD1 code conducted for the purpose of efficient use of VP-100 (peak speed 250 MFLOPS, clock period 7.5 ns) at the JAERI. The code was vectorized using the junction and volume level parallelisms in the hydrodynamic calculations, and the heat-structure and heat-mesh level in the heat conduction calculations. The vectorized version runs as much as 2.4 to 2.8 times faster than the original scalar version, while the speedup ratio is dependent on the number of spactial cells included in the problem. (author)

  18. Numerical simulation of AP1000 LBLOCA with SCDAP/RELAP 4.0 code

    International Nuclear Information System (INIS)

    Xie Heng

    2017-01-01

    The risk of large-break loss of coolant accident (LBLOCA) is that core will be exposed once the accident occurs, and may cause core damages. New phenomena may occur in LBLOCA due to passive safety injection adopted by AP1000. This paper used SCDAP/RELAP5 4.0 to build the numerical model of AP1000 and double-end guillotine of cold leg is simulated. Reactor coolant system and passive core cooling system were modeled by RELAP5 modular. HEAT STRUCTURE component of RELAP5 was used to simulate the fuel rod. The reflood option in RELAP5 was chosen to be activated or not to study the effect of axial heat conduction. Results show that the axial heat conduction plays an important role in the reflooding phase and can effectively shorten reflood process. An alternative core model is built by SCDAP modular. It is found that the SCDAP model predicts higher maximum peak cladding temperature and longer reflood process than RELAP5 model. Analysis shows that clad oxidation heat plays a key role in the reflood. From the simulation results, it can be concluded that the cladding will keep intact and fission product will not be released from fuel to coolant in LBLOCA. (author)

  19. Blowdown heat transfer surface in RELAP4/MOD6 and data comparisons

    International Nuclear Information System (INIS)

    Nelson, R.A.; Sullivan, L.H.

    1978-01-01

    RELAP4 is a thermal hydraulic analysis tool written to analyze transients in light water reactors (LWR). To date, most of the applications for RELAP4 have been to analyze postulated LOCA transients in LWR and the response of experimental systems to loss-of-coolant experiments. An important part of these analyses is the prediction of the fuel rod or heater surface temperature which involves the calculation of surface heat transfer coefficients. The paper describes the outcome of a significant blowdown heat transfer development effort which is incorporated in RELAP4/MOD6 (the current version of the code available to the United States public from the Argonne Code Center). The primary emphasis in the MOD6 development was on a PWR reflood capability. The best-estimate blowdown heat transfer correlation and logic were added to provide improved blowdown predictive capability

  20. RELAP5-3D Developmental Assessment. Comparison of Version 4.3.4i on Linux and Windows

    International Nuclear Information System (INIS)

    Bayless, Paul David

    2015-01-01

    Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code, version 4.3i, compiled on Linux and Windows platforms. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions differ between the Linux and Windows versions.

  1. Capability of the RELAP5 code to simulate natural circulation behaviour in test facilities

    International Nuclear Information System (INIS)

    Mangal, Amit; Jain, Vikas; Nayak, A.K.

    2011-01-01

    In the present study, one of the extensively used best estimate code RELAP5 has been used for simulation of steady state, transient and stability behavior of natural circulation based experimental facilities, such as the High-Pressure Natural Circulation Loop (HPNCL) and the Parallel Channel Loop (PCL) installed and operating at BARC. The test data have been generated for a range of pressure, power and subcooling conditions. The computer code RELAP5/MOD3.2 was applied to predict the transient natural circulation characteristics under single-phase and two-phase conditions, thresholds of flow instability, amplitude and frequency of flow oscillations for different operating conditions of the loops. This paper presents the effect of nodalisation in prediction of natural circulation behavior in test facilities and a comparison of experimental data in with that of code predictions. The errors associated with the predictions are also characterized

  2. Modeling of pipe break accident in a district heating system using RELAP5 computer code

    International Nuclear Information System (INIS)

    Kaliatka, A.; Valinčius, M.

    2012-01-01

    Reliability of a district heat supply system is a very important factor. However, accidents are inevitable and they occur due to various reasons, therefore it is necessary to have possibility to evaluate the consequences of possible accidents. This paper demonstrated the capabilities of developed district heating network model (for RELAP5 code) to analyze dynamic processes taking place in the network. A pipe break in a water supply line accident scenario in Kaunas city (Lithuania) heating network is presented in this paper. The results of this case study were used to demonstrate a possibility of the break location identification by pressure decrease propagation in the network. -- Highlights: ► Nuclear reactor accident analysis code RELAP5 was applied for accident analysis in a district heating network. ► Pipe break accident scenario in Kaunas city (Lithuania) district heating network has been analyzed. ► An innovative method of pipe break location identification by pressure-time data is proposed.

  3. Coupling of RELAP5-3D and GAMMA codes for Nuclear Hydrogen System Analysis

    International Nuclear Information System (INIS)

    Jin, Hyung Gon

    2007-02-01

    RELAP5-3D is one of the most important system analysis codes in nuclear field, which has been developed for best-estimate transient simulation of light water reactor coolant systems during postulated accidents. The GAMMA code is a multi-dimensional multi-component mixture analysis code with the complete set of chemical reaction models which is developed for safety analysis of HTGR (High Temperature Gas Cooled Reactor) air-ingress. The two codes, RELAP5-3D and GAMMA, are coupled to be used for nuclear-hydrogen system analysis, which requires the capability of the analysis of multi-component gas mixture and two-phase flow. In order to couple the two codes, 4 steps are needed. Before coupling, the GAMMA code was transformed into DLL (dynamic link liberally) from executive type and RELAP5-3D was recompiled into Compaq Visual Fortran environments for our debugging purpose. As the second step, two programs - RELAP5-3D and GAMMA codes - must be synchronized in terms of time and time step. Based on that time coupling, the coupled code can calculate simultaneously. Time-step coupling had been accomplished successfully and it is tested by using a simple test input. As a next step, source-term coupling was done and it was also tested in two different test inputs. The fist case is a simple test condition, which has no chemical reaction. And the other test set is the chemical reaction model, including four non-condensable gas species, which are He, O2, CO, CO2. Finally, in order to analyze combined cycle system, heat-flux coupling has been made and a simple heat exchanger model was demonstrated

  4. A coupled RELAPS-3D/CFD methodology with a proof-of-principle calculation; TOPICAL

    International Nuclear Information System (INIS)

    Aumiller, D.L.; Tomlinson, E.T.; Bauer, R.C.

    2000-01-01

    The RELAP5-3D computer code was modified to make the explicit coupling capability in the code fully functional. As a test of the modified code, a coupled RELAP5/RELAP5 analysis of the Edwards-O'Brien blowdown problem was performed which showed no significant deviations from the standard RELAP5-3D predictions. In addition, a multiphase Computational Fluid Dynamics (CFD) code was modified to permit explicit coupling to RELAP5-3D. Several calculations were performed with this code. The first analysis used the experimental pressure history from a point just upstream of the break as a boundary condition. This analysis showed that a multiphase CFD code could calculate the thermodynamic and hydrodynamic conditions during a rapid blowdown transient. Finally, a coupled RELAP5/CFD analysis was performed. The results are presented in this paper

  5. Development of the unified version of COBRA/RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J J; Ha, K S; Chung, B D; Lee, W J; Sim, S K [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The COBRA/RELAP5 code, an integrated version of the COBRA-TF and RELAP5/MOD3 codes, has been developed for the realistic simulations of complicated, multi-dimensional, two-phase, thermal-hydraulic system transients in light water reactors. Recently, KAERI developed an unified version of the COBRA/RELAP5 code, which can run in serial mode on both workstations and personal computers. This paper provides the brief overview of the code integration scheme, the recent code modifications, the developmental assessments, and the future development plan. 13 refs., 5 figs., 2 tabs. (Author)

  6. Development of the unified version of COBRA/RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J. J.; Ha, K. S.; Chung, B. D.; Lee, W. J.; Sim, S. K. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    The COBRA/RELAP5 code, an integrated version of the COBRA-TF and RELAP5/MOD3 codes, has been developed for the realistic simulations of complicated, multi-dimensional, two-phase, thermal-hydraulic system transients in light water reactors. Recently, KAERI developed an unified version of the COBRA/RELAP5 code, which can run in serial mode on both workstations and personal computers. This paper provides the brief overview of the code integration scheme, the recent code modifications, the developmental assessments, and the future development plan. 13 refs., 5 figs., 2 tabs. (Author)

  7. Simulation and Analysis of Small Break LOCA for AP1000 Using RELAP5-MV and Its Comparison with NOTRUMP Code

    Directory of Open Access Journals (Sweden)

    Eltayeb Yousif

    2017-01-01

    Full Text Available Many reactor safety simulation codes for nuclear power plants (NPPs have been developed. However, it is very important to evaluate these codes by testing different accident scenarios in actual plant conditions. In reactor analysis, small break loss of coolant accident (SBLOCA is an important safety issue. RELAP5-MV Visualized Modularization software is recognized as one of the best estimate transient simulation programs of light water reactors (LWR. RELAP5-MV has new options for improved modeling methods and interactive graphics display. Though the same models incorporated in RELAP5/MOD 4.0 are in RELAP5-MV, the significant difference of the latter is the interface for preparing the input deck. In this paper, RELAP5-MV is applied for the transient analysis of the primary system variation of thermal hydraulics parameters in primary loop under SBLOCA in AP1000 NPP. The upper limit of SBLOCA (10 inches is simulated in the cold leg of the reactor and the calculations performed up to a transient time of 450,000.0 s. The results obtained from RELAP5-MV are in good agreement with those of NOTRUMP code obtained by Westinghouse when compared under the same conditions. It can be easily inferred that RELAP5-MV, in a similar manner to RELAP5/MOD4.0, is suitable for simulating a SBLOCA scenario.

  8. RELAP-7 Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Ray Alden [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Peterson, John William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, Richard Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kadioglu, Samet Yucel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This document summarizes the physical models and mathematical formulations used in the RELAP-7 code. In summary, the MOOSE based RELAP-7 code development is an ongoing effort. The MOOSE framework enables rapid development of the RELAP-7 code. The developmental efforts and results demonstrate that the RELAP-7 project is on a path to success. This theory manual documents the main features implemented into the RELAP-7 code. Because the code is an ongoing development effort, this RELAP-7 Theory Manual will evolve with periodic updates to keep it current with the state of the development, implementation, and model additions/revisions.

  9. Recent SCDAP/RELAP5 code applications and improvements

    International Nuclear Information System (INIS)

    Harvego, E.A.; Ghan, L.S.; Knudson, D.L.; Siefken, L.J.

    1998-01-01

    This paper summarizes (1) a recent application of the severe accident analysis code SCDAP/RELAP5/MOD3.1, and (2) development and assessment activities associated with the release of SACDAP/RELAP5/MOD3.2. The Nuclear Regulatory Commission (NRC) has been evaluating the integrity of steam generator tubes during severe accidents. MOD3.1 has been used to support that evaluation. Studies indicate that the pressurizer surge line will fail before any steam generator tubes are damaged. Thus, core decay energy would be released as steam through the surge line and the tube wall would be spared from exposure to prolonged flow of high temperature steam. The latest code version, MOD3.2, contains several improvements to models that address both the early phase and late phase of a severe accident. The impact of these improvements to the overall code capabilities has been assessed. Results of the assessment are summarized in this paper

  10. Insertion of lead lithium eutectic mixture in RELAP/SCDAPSIM Mod 4.0 for Fusion Reactor Systems

    International Nuclear Information System (INIS)

    Tiwari, Ashutosh; Allison, Brian; Hohorst, J.K.; Wagner, R.J.; Allison, Chris

    2012-01-01

    Highlights: ► Thermodynamic and transport properties of lead lithium eutectic mixture have been inserted in RELAP/SCDAPSIM MOD 4.0 code. ► Code results are verified for a simple pipe problem with lead lithium eutectic mixture flowing in it. ► Code is calculating the inserted properties of lead lithium eutectic mixture to a fairly good agreement. - Abstract: RELAP/SCDAPSIM Mod 4.0 code was developed by Innovative System Software (ISS) for the analysis of nuclear power plants (NPPs) cooled by light water and heavy water. Later on the code was expanded to analyze the NPPs cooled by liquid metal, in this sequence: lead bismuth eutectic mixture, liquid sodium and lead lithium eutectic mixture (LLE) are inserted in the code. This paper focuses on the insertion of liquid LLE as a coolant for NPPs in the RELAP/SCDAPSIM Mod 4.0 code. Evaluation of the code was made for a simple pipe problem connected with heat structures having liquid LLE as a coolant in it. The code is predicting well all the thermodynamic and transport properties of LLE.

  11. RELAP5-3D Developmental Assessment: Comparison of Versions 4.2.1i and 4.1.3i

    Energy Technology Data Exchange (ETDEWEB)

    Bayless, Paul D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-06-01

    Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.2.1i and 4.1.3i. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

  12. Simulation of water hammer experiments using RELAP5 code

    International Nuclear Information System (INIS)

    Kaliatka, A.; Vaisnoras, M.

    2005-01-01

    The rapid closing or opening of a valve causes pressure transients in pipelines. The fast deceleration of the liquid results in high pressure surges upstream the valve, thus the kinetic energy is transformed into the potential energy, which leads to the temporary pressure increases. This phenomenon is called water hammer. The intensity of water hammer effects will depend upon the rate of change in the velocity or momentum. Generally water hammer can occur in any thermal-hydraulic systems and it is extremely dangerous for the thermal-hydraulic system since, if the pressure induced exceeds the pressure range of a pipe given by the manufacturer, it can lead to the failure of the pipeline integrity. Due to its potential for damage of pipes, water hammer has been a subject of study since the middle of the nineteenth century. Many theoretical and experimental investigations were performed. The experimental investigation of the water hammer tests performed at Fraunhofer Institute for Environmental, Safety and Energy Technology (UMSICHT) [1] and Cold Water Hammer experiment performed by Forschungszentrum Rossendorf (CWHTF) [2] should be mentioned. The UMSICHT facility in Oberhausen was modified in order to simulate a piping system and associated supports that are typical for a nuclear power plant [3]. The Cold water hammer experiment is interesting and instructive because it covers a wide spectrum of particularities. One of them is sub-cooled water interaction with condensing steam at the closed end of the vertical pipe at room temperature and corresponding saturation pressure [4]. In the paper, the capabilities of RELAP5 code to correctly represent the water hammer phenomenon are presented. Paper presents the comparison of RELAP5 calculated and measured at UMSICHT and CWHTF test facilities pressure transient values after the fast closure (opening) of valves. The analyses of rarefaction wave travels inside the pipe and condensation of vapour bubbles in the liquid column

  13. RELAP5/MOD3 code manual: Code structure, system models, and solution methods. Volume 1

    International Nuclear Information System (INIS)

    1995-08-01

    The RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents, and operational transients, such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling, approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I provides modeling theory and associated numerical schemes

  14. RELAP-7 Software Verification and Validation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Curtis L. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Risk, Reliability, and Regulatory Support; Choi, Yong-Joon [Idaho National Lab. (INL), Idaho Falls, ID (United States). Risk, Reliability, and Regulatory Support; Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States). Risk, Reliability, and Regulatory Support

    2014-09-25

    This INL plan comprehensively describes the software for RELAP-7 and documents the software, interface, and software design requirements for the application. The plan also describes the testing-based software verification and validation (SV&V) process—a set of specially designed software models used to test RELAP-7. The RELAP-7 (Reactor Excursion and Leak Analysis Program) code is a nuclear reactor system safety analysis code being developed at Idaho National Laboratory (INL). The code is based on the INL’s modern scientific software development framework – MOOSE (Multi-Physics Object-Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5’s capability and extends the analysis capability for all reactor system simulation scenarios.

  15. Benchmark evaluation of the RELAP code to calculate boiling in narrow channels

    International Nuclear Information System (INIS)

    Kunze, J.F.; Loyalka, S.K.; McKibben, J.C.; Hultsch, R.; Oladiran, O.

    1990-01-01

    The RELAP code has been tested with benchmark experiments (such as the loss-of-fluid test experiments at the Idaho National Engineering Laboratory) at high pressures and temperatures characteristic of those encountered in loss-of-coolant accidents (LOCAs) in commercial light water power reactors. Application of RELAP to the LOCA analysis of a low pressure (< 7 atm) and low temperature (< 100 degree C), plate-type research reactor, such as the University of Missouri Research Reactor (MURR), the high-flux breeder reactor, high-flux isotope reactor, and Advanced Test Reactor, requires resolution of questions involving overextrapolation to very low pressures and low temperatures, and calculations of the pulsed boiling/reflood conditions in the narrow rectangular cross-section channels (typically 2 mm thick) of the plate fuel elements. The practical concern of this problem is that plate fuel temperatures predicted by RELAP5 (MOD2, version 3) during the pulsed boiling period can reach high enough temperatures to cause plate (clad) weakening, though not melting. Since an experimental benchmark of RELAP under such LOCA conditions is not available and since such conditions present substantial challenges to the code, it is important to verify the code predictions. The comparison of the pulsed boiling experiments with the RELAP calculations involves both visual observations of void fraction versus time and measurements of temperatures near the fuel plate surface

  16. Method for quantitative assessment of nuclear safety computer codes

    International Nuclear Information System (INIS)

    Dearien, J.A.; Davis, C.B.; Matthews, L.J.

    1979-01-01

    A procedure has been developed for the quantitative assessment of nuclear safety computer codes and tested by comparison of RELAP4/MOD6 predictions with results from two Semiscale tests. This paper describes the developed procedure, the application of the procedure to the Semiscale tests, and the results obtained from the comparison

  17. Code Development in Coupled PARCS/RELAP5 for Supercritical Water Reactor

    Directory of Open Access Journals (Sweden)

    Po Hu

    2014-01-01

    Full Text Available The new capability is added to the existing coupled code package PARCS/RELAP5, in order to analyze SCWR design under supercritical pressure with the separated water coolant and moderator channels. This expansion is carried out on both codes. In PARCS, modification is focused on extending the water property tables to supercritical pressure, modifying the variable mapping input file and related code module for processing thermal-hydraulic information from separated coolant/moderator channels, and modifying neutronics feedback module to deal with the separated coolant/moderator channels. In RELAP5, modification is focused on incorporating more accurate water properties near SCWR operation/transient pressure and temperature in the code. Confirming tests of the modifications is presented and the major analyzing results from the extended codes package are summarized.

  18. SCDAP/RELAP5/MOD 3.1 code manual: Interface theory. Volume 1

    International Nuclear Information System (INIS)

    Coryell, E.W.

    1995-06-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, core, fission product released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of off-site power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume describes the organization and manner of the interface between severe accident models which are resident in the SCDAP portion of the code and hydrodynamic models which are resident in the RELAP5 portion of the code. A description of the organization and structure of SCDAP/RELAP5 is presented. Additional information is provided regarding the manner in which models in one portion of the code impact other parts of the code, and models which are dependent on and derive information from other subcodes

  19. Implementation of PWR steady state self-initialization feature into RELAP4/MOD6/U4/J3

    International Nuclear Information System (INIS)

    Yoshida, Kazuo

    1987-07-01

    A PWR steady state self-initialization feature has been implemented into the RELAP4/MOD6/U4/J3 code which is an improved version of RELAP4/MOD6 and can analyze not only large break but also small break LOCA in LWRs. This feature is originated from RELAP4/MOD7 which is the most updated released version of RELAP4 from INEL. Several FORTRAN subroutines in MOD7 related to this feature were transplanted into MOD6/U4/J3 with some improvements, which were the modification of method to take a balance of heat transfer between primary and secondary side at SG-U tubes, and to make it possible to nodalize secondary side of SG as multi-node. Advantages realized by implementation of this option are saving of time in initializaing a new model and an assurance of steady state and self consistency of input data in a small break LOCA analysis of a PWR. (author)

  20. RELAP5-3D code validation for RBMK phenomena

    International Nuclear Information System (INIS)

    Fisher, J.E.

    1999-01-01

    The RELAP5-3D thermal-hydraulic code was assessed against Japanese Safety Experiment Loop (SEL) and Heat Transfer Loop (HTL) tests. These tests were chosen because the phenomena present are applicable to analyses of Russian RBMK reactor designs. The assessment cases included parallel channel flow fluctuation tests at reduced and normal water levels, a channel inlet pipe rupture test, and a high power, density wave oscillation test. The results showed that RELAP5-3D has the capability to adequately represent these RBMK-related phenomena

  1. Calculations of flow oscillations during reflood using RELAP4/MOD6

    International Nuclear Information System (INIS)

    Chen, Y.S.; Fischer, S.R.; Sullivan, L.H.

    1979-01-01

    RELAP4/MOD6 is an analytical computer code which can be used for best-estimate analysis of LWR reactor system blowdown and reflood response to a postulated LOCA. In this study, flow oscillations in the PKL reflood test K5A were investigated using RELAP4/MOD6. Both calculated and measured oscillations exhibited transient characteristics of density-wave and pressure-drop oscillations. The calculated average core mixture level rising rate agrees closely with the test data. Several mechanisms which appear to be responsible for initiation and continuation of calculated or experimental reflood flow oscillations are (a) the coupling between the vapor generation in the core channel and the U-tube geometrical arrangement of a downcomer and a heated core; (b) the inherent low core inlet resistance and the high system outlet resistance; (c) the dependence of heat transfer rate on mass flow rate especially in the dispersed flow ially in the dispersed flow regime; (d) the amount of the liquid entrainment fraction of the heated core channel

  2. RELAP5 progress summary: simulation of semiscale isothermal blowdown (Test S-01-4A)

    International Nuclear Information System (INIS)

    Kuo, H.H.; Wagner, R.J.; Carlson, K.E.; Kiser, D.M.; Trapp, J.A.; Ransom, V.H.

    1978-07-01

    The RELAP5/MOD''O'' LOCA analysis code has been applied to Simulation of the Semiscale Isothermal Blowdown Test (S-01-4A) from initiation to 60 seconds. Subcooled ECC injection was simulated from 23 seconds until accumulator emptying. The calculated results are in very good agreement with the experimental data. This is the first full system application of the RELAP5 code and only the pressurizer surge line resistance was modified to achieve the results reported. An analysis of the code execution time using a time-step statistical edit is included

  3. Modelling of the Rod Control System in the coupled code RELAP5-QUABOX/CUBBOX

    International Nuclear Information System (INIS)

    Bencik, V.; Feretic, D.; Grgic, D.

    1999-01-01

    There is a general agreement that for many light water reactor transient calculations, it is necessary to use a multidimensional neutron kinetics model coupled to sophisticated thermal-hydraulic models in order to obtain satisfactory results. These calculations are needed for a variety of applications for licensing safety analyses, probabilistic risk assessment, operational support, and training. At FER, Zagreb, a coupling of 3D neutronics code QUABOX/CUBBOX and system code RELAP5 was performed. In the paper the Rod Control System model in the RELAP5 part of the coupled code is presented. A first testing of the model was performed by calculation of reactor trip from full power for NPP Krsko. Results of 3D neutronics calculation obtained by coupled code QUABOX/CUBBOX were compared with point kinetics calculation performed with RELAP5 stand alone code.(author)

  4. Analysis of LOFT (L1-2) experiment by code RELAP-4J

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Soda, Kunihisa; Shiba, Masayoshi; Kaminaga, Humito

    1977-04-01

    An analysis of the results in LOFT L1-2 LOCE (Loss of Coolant Experiment) was made by the computer code RELAP-4J. The L1-2 experiment is a simple isothermal blowdown test with a core simulator and no ECC activation. It provides the basis for future LOCE with a nuclear core and ECC activation. The results of the analysis lead to the following conclusions. (1) The calculated system pressure transient agrees well with experiment. Primary controlling factors for the calculation are (a) flow resistances of the steam generator simulator, pump simulator and discharge nozzle in the broken loop, (b) mixture level in the downcomer and inlet volume of the operating loop steam generator, and (c) stored heat of the downcomer structure. (2) The pressurizer pressure decreases rapidly, compared with experiment, possibly because the flow resistance in the surge line is smaller than the actual one. Further experiment and analysis are necessary in this respect. (3) The calculated density transient in the cold leg agrees well with experiment. Agreement is not good in the hot leg, however. The discrepancy is possibly caused by the non-homogeneous flow of coolant in the hot leg due to low flow rate. (4) Effect of the pump characteristics on analytical result is insignificant in the isothermal test. However, in the future nuclear test, the effect will be significant because of large steam generation in the core, so measurement of the pump characteristics and improvement of the pump model are necessary. (auth.)

  5. RELAP/MOD3 code manual: User's guidelines. Volume 5, Revision 1

    International Nuclear Information System (INIS)

    Fletcher, C.D.; Schultz, R.R.

    1995-08-01

    The RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents, and operational transients, such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. Volume V contains guidelines that have solved over the past several years through the use of the RELAP5 code

  6. Simulation of LOCA power transients of CANDU6 by SCAN/RELAP-CANDU coupled code system

    International Nuclear Information System (INIS)

    Hong, In Seob; Kim, Chang Hyo; Hwang, Su Hyun; Kim, Man Woong; Chung, Bub Dong

    2004-01-01

    As can be seen in the standalone application of RELAP-CANDU for LOCA analysis of CANDU-PHWR, the system thermal-hydraulic code alone cannot predict the transient behavior accurately. Therefore, best estimate neutronics and system thermal-hydraulic coupled code system is necessary to describe the transient behavior with higher accuracy and reliability. The purpose of this research is to develop and test a coupled neutronics and thermal-hydraulics analysis code, SCAN (SNU CANDU-PHWR Neutronics) and RELAP-CANDU, for transient analysis of CANDU-PHWR's. For this purpose, a spatial kinetics calculation module of SCAN, a 3-D CANDU-PHWR neutronics design and analysis code, is dynamically coupled with RELAP-CANDU, the system thermal-hydraulic code for CANDU-PHWR. The performance of the coupled code system is examined by simulation of reactor power transients caused by a hypothetical Loss Of Coolant Accident (LOCA) in Wolsong units, which involves the insertion of positive void reactivity into the core in the course of transients. Specifically, a 40% Reactor Inlet Header (RIH) break LOCA was assumed for the test of the SCAN/RELAP-CANDU coupled code system analysis

  7. RELAP-7 Numerical Stabilization: Entropy Viscosity Method

    Energy Technology Data Exchange (ETDEWEB)

    R. A. Berry; M. O. Delchini; J. Ragusa

    2014-06-01

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The code is based on the INL's modern scientific software development framework, MOOSE (Multi-Physics Object Oriented Simulation Environment). The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in computer architecture, software design, numerical integration methods, and physical models. The end result will be a reactor systems analysis capability that retains and improves upon RELAP5's capability and extends the analysis capability for all reactor system simulation scenarios. RELAP-7 utilizes a single phase and a novel seven-equation two-phase flow models as described in the RELAP-7 Theory Manual (INL/EXT-14-31366). The basic equation systems are hyperbolic, which generally require some type of stabilization (or artificial viscosity) to capture nonlinear discontinuities and to suppress advection-caused oscillations. This report documents one of the available options for this stabilization in RELAP-7 -- a new and novel approach known as the entropy viscosity method. Because the code is an ongoing development effort in which the physical sub models, numerics, and coding are evolving, so too must the specific details of the entropy viscosity stabilization method. Here the fundamentals of the method in their current state are presented.

  8. Advanced Presentation of BETHSY 6.2TC Test Results Calculated by RELAP5 and TRACE

    Directory of Open Access Journals (Sweden)

    Andrej Prošek

    2012-01-01

    Full Text Available Today most software applications come with a graphical user interface, including U.S. Nuclear Regulatory Commission TRAC/RELAP Advanced Computational Engine (TRACE best-estimate reactor system code. The graphical user interface is called Symbolic Nuclear Analysis Package (SNAP. The purpose of the present study was to assess the TRACE computer code and to assess the SNAP capabilities for input deck preparation and advanced presentation of the results. BETHSY 6.2 TC test was selected, which is 15.24 cm equivalent diameter horizontal cold leg break. For calculations the TRACE V5.0 Patch 1 and RELAP5/MOD3.3 Patch 4 were used. The RELAP5 legacy input deck was converted to TRACE input deck using SNAP. The RELAP5 and TRACE comparison to experimental data showed that TRACE results are as good as or better than the RELAP5 calculated results. The developed animation masks were of great help in comparison of results and investigating the calculated physical phenomena and processes.

  9. Waste Evaporator Accident Simulation Using RELAP5 Computer Code

    International Nuclear Information System (INIS)

    POLIZZI, L.M.

    2004-01-01

    An evaporator is used on liquid waste from processing facilities to reduce the volume of the waste through heating the waste and allowing some of the water to be separated from the waste through boiling. This separation process allows for more efficient processing and storage of liquid waste. Commonly, the liquid waste consists of an aqueous solution of chemicals that over time could induce corrosion, and in turn weaken the tubes in the steam tube bundle of the waste evaporator that are used to heat the waste. This chemically induced corrosion could escalate into a possible tube leakage and/or the severance of a tube(s) in the tube bundle. In this paper, analyses of a waste evaporator system for the processing of liquid waste containing corrosive chemicals are presented to assess the system response to this accident scenario. This accident scenario is evaluated since its consequences can propagate to a release of hazardous material to the outside environment. It is therefore important to ensure that the evaporator system component structural integrity is not compromised, i.e. the design pressure and temperature of the system is not exceeded during the accident transient. The computer code used for the accident simulation is RELAP5-MOD31. The accident scenario analyzed includes a double-ended guillotine break of a tube in the tube bundle of the evaporator. A mitigated scenario is presented to evaluate the excursion of the peak pressure and temperature in the various components of the evaporator system to assess whether the protective actions and controls available are adequate to ensure that the structural integrity of the evaporator system is maintained and that no atmospheric release occurs

  10. Self-initialization module for the RELAP4/MOD7 program

    International Nuclear Information System (INIS)

    Behling, S.R.; Burgess, C.H.; Johnsen, G.W.

    1979-01-01

    An automated self-initialization option has been developed and implemented into the RELAP4/MOD7 computer code. With this new feature, pressurized water reactors or similar models may be initialized to steady state conditions with minimal user-supplied input data. Previously, the analyst (user) had to hand compute all pressures and temperatures in conjunction with several iterative computer runs. Two semi-independent functions, pressure balancing and thermal balancing, comprise the self-initialization module. The user supplies input data specifying a reference pressure and temperature and associated locations. Control volume pressures and temperatures are computed consistent with the nodalization, geometry, total power, and mass flow rates specified. Verification has been accomplished by performing transient calculations on system models and observing the persistence of stable operating conditions. Preparation of input data for the self-initialization module seldom requires more than several man-hours. Computing time required on a CDC 7600 computer to complete the self-initialization process is typically less than 30 seconds

  11. SCDAP/RELAP5 independent peer review

    Energy Technology Data Exchange (ETDEWEB)

    Corradini, M.L. [Wisconsin Univ., Madison, WI (United States). Dept. of Nuclear Engineering; Dhir, V.K. [Dhir, (V.K.) Santa Monica, CA (United States); Haste, T.J. [AEA Technology, Winfrith (United Kingdom); Heames, T.J. [Science Applications, Inc., Albuquerque, NM (United States); Jenks, R.P. [Los Alamos National Lab., NM (United States); Kelly, J.E. [Sandia National Labs., Albuquerque, NM (United States); Khatib-Rahbar, M. [Energy Research, Inc., Rockville, MD (United States); Viskanta, R. [Purdue Univ., Lafayette, IN (United States). Heat Transfer Lab.

    1993-01-01

    The SCDAP/RELAP5 code has been developed for best-estimate transient simulation of light-water-reactor coolant systems during severe accidents. The newest version of the code is SCDAP/RELAP5/MOD3. The US Nuclear Regulatory Commission (NRC) decided that there was a need for a broad technical review of the code by recognized experts to determine overall technical adequacy, even though the code is still under development. For this purpose, an eight-member SCDAP/RELAP5 Peer Review Committee was organized, and the outcome of the review should help the NRC prioritize future code-development activity. Because the code is designed to be mechanistic, the Committee used a higher standard for technical adequacy than was employed in the peer review of the parametric MELCOR code. The Committee completed its review of the SCDAP/RELAP5 code, and the findings are documented in this report. Based on these findings, recommendations in five areas are provided: (1) phenomenological models, (2) code-design objectives, (3) code-targeted applications, (4) other findings, and (5) additional recommendations.

  12. SCDAP/RELAP5 independent peer review

    International Nuclear Information System (INIS)

    Corradini, M.L.; Haste, T.J.; Heames, T.J.; Jenks, R.P.; Kelly, J.E.; Khatib-Rahbar, M.; Viskanta, R.

    1993-01-01

    The SCDAP/RELAP5 code has been developed for best-estimate transient simulation of light-water-reactor coolant systems during severe accidents. The newest version of the code is SCDAP/RELAP5/MOD3. The US Nuclear Regulatory Commission (NRC) decided that there was a need for a broad technical review of the code by recognized experts to determine overall technical adequacy, even though the code is still under development. For this purpose, an eight-member SCDAP/RELAP5 Peer Review Committee was organized, and the outcome of the review should help the NRC prioritize future code-development activity. Because the code is designed to be mechanistic, the Committee used a higher standard for technical adequacy than was employed in the peer review of the parametric MELCOR code. The Committee completed its review of the SCDAP/RELAP5 code, and the findings are documented in this report. Based on these findings, recommendations in five areas are provided: (1) phenomenological models, (2) code-design objectives, (3) code-targeted applications, (4) other findings, and (5) additional recommendations

  13. Quality control of the packet of RELAP5/MOD2 code

    International Nuclear Information System (INIS)

    Pomier Baez, L.E.

    1993-01-01

    The methodology that should be used to perform the quality control of entrance data set of RELAP5 calculation code is expounded in this work with this control method an extreme reliability is quarantined in the calculation model established to perform the safety thermohydraulic analysis with the help of RELAP5. This makes possible the complex simulation studies of a nuclear power plant with the quality required

  14. Steady state and LOCA analysis of Kartini reactor using RELAP5/SCDAP code: The role of passive system

    Science.gov (United States)

    Antariksawan, Anhar R.; Wahyono, Puradwi I.; Taxwim

    2018-02-01

    Safety is the priority for nuclear installations, including research reactors. On the other hand, many studies have been done to validate the applicability of nuclear power plant based best estimate computer codes to the research reactor. This study aims to assess the applicability of the RELAP5/SCDAP code to Kartini research reactor. The model development, steady state and transient due to LOCA calculations have been conducted by using RELAP5/SCDAP. The calculation results are compared with available measurements data from Kartini research reactor. The results show that the RELAP5/SCDAP model steady state calculation agrees quite well with the available measurement data. While, in the case of LOCA transient simulations, the model could result in reasonable physical phenomena during the transient showing the characteristics and performances of the reactor against the LOCA transient. The role of siphon breaker hole and natural circulation in the reactor tank as passive system was important to keep reactor in safe condition. It concludes that the RELAP/SCDAP could be use as one of the tool to analyse the thermal-hydraulic safety of Kartini reactor. However, further assessment to improve the model is still needed.

  15. A Comparison of Nuclear Power Plant Simulator with RELAP5/MOD3 code about Steam Generator Tube Rupture

    International Nuclear Information System (INIS)

    Kim, Sung Hyun; Moon, Chan Ki; Park, Sung Baek; Na, Man Gyun

    2013-01-01

    The RELAP5/MOD3 code introduced in cooperation with U. S. NRC has been utilized mainly for validation calculation of accident analysis submitted by licensee in Korea. The Korea Institute of Nuclear Safety has built a verification system of LWR accident analysis with RELAP5/MOD3 code engine. Therefore, the simulator replicates the design basis accident and its results are compared with RELAP5/MOD3 code results that will have important implications in the verification of the simulator in the future. The SGTR simulations were performed by the simulator and its results were compared with ones by RELAP5/MOD3 code in this study. Thus, the results of this study can be used as materials to build the verification system of the nuclear power plant simulator. We tried to compare with RELAP5/MOD3 verification code by replicating major parameters of steam generator tube rupture using the simulator for OPR-1000 in Yonggwang training center. By comparing the changes in temperature, pressure and inventory of the reactor coolant system and main steam system during the SGTR, it was confirmed that the main behaviors of SGTR which the simulator and RELAP5/MOD3 code showed are similar. However, the behavior of SG pressure and level that are important parameters to diagnose the accident were a little different. We estimated that RELAP5/MOD3 code was not reflected the major control systems in detail, such as FWCS, SBCS and PPCS. The different behaviors of SG level and pressure in this study should be needed an additional review. As a result of the comparison, the major simulation parameters behavior by RELAP5/MOD3 code agreed well with the one by the simulator. Therefore, it is thought that RELAP5/MOD3 code is used as a tool for validation of NPP simulator in the near future through this study

  16. The gradual development steps of the external coupled RELAP5 - DYN3D code

    International Nuclear Information System (INIS)

    Strmensky, C.

    2001-01-01

    This paper describes the on-going and finished parts of project: 'The external coupled RELAP5-DYN3D code'. The development progress was divided into four steps. In present time, second and third steps are performed and four step is started. The two parameters of coolant was selected and are exchanged between codes RELAP5 and DYN3D. (authors)

  17. The implementation of the CDC version of RELAP5/MOD1/019 on an IBM compatible computer system (AMDAHL 470/V8)

    International Nuclear Information System (INIS)

    Kolar, W.; Brewka, W.

    1984-01-01

    RELAP5/MOD1 is an advanced one-dimensional best estimate system code, which is used for safety analysis studies of nuclear pressurized water reactor systems and related integral and separate effect test facilities. The program predicts the system response for large break, small break LOCA and special transients. To a large extent RELAP5/MOD1 is written in Fortran, only a small part of the program is coded in CDC assembler. RELAP5/MOD1 was developed on the CDC CYBER 176 at INEL*. The code development team made use of CDC system programs like the CDC UPDATE facility and incorporated in the program special purpose software packages. The report describes the problems which have been encountered when implementing the CDC version of RELAP5/MOD1 on an IBM compatible computer systems (AMDAHL 470/V8)

  18. RELAP5 analyses of overcooling transients in a pressurized water reactor

    International Nuclear Information System (INIS)

    Bolander, M.A.; Fletcher, C.D.; Ogden, D.M.; Stitt, B.D.; Waterman, M.E.

    1983-01-01

    In support of the Pressurized Thermal Shock Integration Study sponsored by the United States Nuclear Regulatory Commission, the Idaho National Engineering Laboratory has performed analyses of overcooling transients using the RELAP5/MOD1.5 computer code. These analyses were performed for Oconee Plants 1 and 3, which are pressurized water reactors of Babcock and Wilcox lowered-loop design. Results of the RELAP5 analyses are presented, including a comparison with plant data. The capabilities and limitations of the RELAP5/MOD1.5 computer code in analyzing integral plant transients are examined. These analyses require detailed thermal-hydraulic and control system computer models

  19. RELAP5-3D version 4.0.3: installation and tests for applications to space reactors

    International Nuclear Information System (INIS)

    Lobo, Paulo D.C.; Braz Filho, Francisco A.; Borges, Eduardo M.; Guimaraes, Lamartine N.F.; Sabundjian, Gaiane

    2013-01-01

    To attend the TERRA project (Tecnologia de Reatores Rapidos Avancados), currently conducted by the Nuclear Energy Division (ENU) of the IEAv, this work presents the RELAP5-3D, Version 4.0.3, prepared in July 12, 2012, also known as r3d403is, received recently by the IEAv from the Idaho National Laboratory (INL). This version of RELAP5-3D is configured for the International User Group source Code Group and is developed and maintained at the INL for the US Department of Energy. RELAP5-3D, the latest in the series of RELAP5 codes, is a highly generic code that, in addition to calculating the behavior of a reactor coolant system during a transient, can be used for simulation of a wide variety of hydraulic and thermal transients in both nuclear and nonnuclear systems involving mixtures of vapor, liquid, noncondensable gases, and nonvolatile solute. Enhancements include all features and models previously available in the ATHENA configuration version of the code which are as follows: addition of new work fluids and a magneto-hydrodynamic mode. Following the instructions from the README file, the RELAP5-3D, version 4.0.3 was installed creating the necessaries subdirectories, by using the LINUX platform and applying both Intel Fortran 95 and C-language compilers. Many input examples were executed and the same results were observed as compared to the received documentation. A sample of the Edwards-O'Brien test was evaluated to verify if the code could simulate a LOCA type accident properly. The test executed by the RELAP5-3D demonstrated good agreement with test data including a new output involving the mass flow during the test. (author)

  20. RELAP5-3D version 4.0.3: installation and tests for applications to space reactors

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Paulo D.C.; Braz Filho, Francisco A.; Borges, Eduardo M.; Guimaraes, Lamartine N.F., E-mail: plobo.a@uol.com.br, E-mail: fbraz@ieav.cta.br, E-mail: eduardo@ieav.cta.br, E-mail: guimarae@ieav.cta.br [Instituto de Estudos Avancados (IEAv), Sao Jose dos Campos, SP (Brazil); Sabundjian, Gaiane, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    To attend the TERRA project (Tecnologia de Reatores Rapidos Avancados), currently conducted by the Nuclear Energy Division (ENU) of the IEAv, this work presents the RELAP5-3D, Version 4.0.3, prepared in July 12, 2012, also known as r3d403is, received recently by the IEAv from the Idaho National Laboratory (INL). This version of RELAP5-3D is configured for the International User Group source Code Group and is developed and maintained at the INL for the US Department of Energy. RELAP5-3D, the latest in the series of RELAP5 codes, is a highly generic code that, in addition to calculating the behavior of a reactor coolant system during a transient, can be used for simulation of a wide variety of hydraulic and thermal transients in both nuclear and nonnuclear systems involving mixtures of vapor, liquid, noncondensable gases, and nonvolatile solute. Enhancements include all features and models previously available in the ATHENA configuration version of the code which are as follows: addition of new work fluids and a magneto-hydrodynamic mode. Following the instructions from the README file, the RELAP5-3D, version 4.0.3 was installed creating the necessaries subdirectories, by using the LINUX platform and applying both Intel Fortran 95 and C-language compilers. Many input examples were executed and the same results were observed as compared to the received documentation. A sample of the Edwards-O'Brien test was evaluated to verify if the code could simulate a LOCA type accident properly. The test executed by the RELAP5-3D demonstrated good agreement with test data including a new output involving the mass flow during the test. (author)

  1. Utilization of the RELAP4 in the experimental water loop of the IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Sabundjian, G.

    1991-09-01

    For a better security of the nuclear power station and the population, thermal hydraulics codes for accident analysis were developed. Within all codes, the RELAP4, developed by Aerojet Nuclear Company of the Idaho Falls Engineering Laboratory (U.S.A.), has been the more used mostly by the fact of been available to the public. These code presents the most satisfactory results when used for various sort of problems. Basely the paper analyzes and compares the RELAP4/MOD3 and MOD5 versions, through the simulation on the Water Experimental Loop (C.E.A.) of the IPEN, in the steady state and in accidents conditions. Although the C.E.A. had been constructed to simulate PWR and BWR reactors, in these paper the tests were made only for PWR. Through the results analysis found in these paper, we concluded that the model adaptation for the simulations made with the RELAP4 code (version MOD3 and MOD5), were satisfactory. The accidents simulations indicates that the C.E.A. can support accident situation with the emergency system acting. Comparing the two versions, the MOD5 presented the better results compared with the real estimations. (author)

  2. Implementation of an enlarged model of the safety valves and relief in the plant integral model for the code RELAP/SCDAPSIM; Implementacion de un modelo ampliado de las valvulas de seguridad y alivio en el modelo integral de planta para el codigo RELAP/SCDAPSIM

    Energy Technology Data Exchange (ETDEWEB)

    Amador G, R.; Ortiz V, J.; Castillo D, R. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Hernandez L, E. J. [Instituto Tecnologico de Toluca, Av. Tecnologico s/n, Fracc. La Virgen, 52149 Metepec, Estado de Mexico (Mexico); Galeana R, J. C. [Universidad del Valle de Mexico, Campus Toluca, Av. de Las Palmas 136, 52140 Metepec, Estado de Mexico (Mexico); Gutierrez, V. H., E-mail: rodolfo.amador@inin.gob.mx [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Av. San Pablo 180, Col. Reynosa Tamaulipas, 02200 Mexico D. F. (Mexico)

    2013-10-15

    The present work refers to the implementation of a new model on the logic of the safety valves and relief in the integral model of the Nuclear Power Plant of Laguna Verde of the thermal-hydraulic compute code RELAP/SCDAPSIM Mod. 3.4. The new model was developed with the compute package SIMULINK-MATLAB and contemplates all the operation options of the safety valves and relief, besides including the availability options of the valves in all the operation ways and of blockage in the ways of relief and low-low. The implementation means the elimination of the old model of the safety valves and to analyze the group of logical variables, of discharge and available control systems to associate them to the model of package SIMULINK-MATLAB. The implementation has been practically transparent and 27 cases corresponding to a turbine discharge were analyzed with the code RELAP/SCDAPSIM Mod. 3.4. The results were satisfactory. (Author)

  3. Study on coupling of three-dimension space time neutron kinetics model and RELAP5 and improvement of RELAP5

    International Nuclear Information System (INIS)

    Gui Xuewen; Cai Qi; Luo Bangqi

    2007-01-01

    A two-group three-dimension space-time neutron kinetics model is applied to the RELAP5 code, which replaces the point reactor kinetics model. A visual operation interface is designed to convenience interactive operation between operator and computer. The calculation results and practical applications indicate that the functions and precision of improved RELAP5 are enhanced and can be easily used. The improved RELAP5 has a good application perspective in nuclear power plant simulation. (authors)

  4. RELAP/MOD3 code manual: User`s guidelines. Volume 5, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, C.D.; Schultz, R.R. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1995-08-01

    The RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents, and operational transients, such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. Volume V contains guidelines that have solved over the past several years through the use of the RELAP5 code.

  5. Development and application of a system analysis code for liquid fueled molten salt reactors based on RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Chengbin [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Cheng, Maosong, E-mail: mscheng@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Liu, Guimin [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2016-08-15

    Highlights: • New point kinetics and thermo-hydraulics models as well as a numerical method are added into RELAP5 code to be suitable for liquid fueled molten salt reactor. • The extended REALP5 code is verified by the experimental benchmarks of MSRE. • The different transient scenarios of the MSBR are simulated to evaluate performance during the transients. - Abstract: The molten salt reactor (MSR) is one of the six advanced reactor concepts declared by the Generation IV International Forum (GIF), which can be characterized by attractive attributes as inherent safety, economical efficiency, natural resource protection, sustainable development and nuclear non-proliferation. It is important to make system safety analysis for nuclear power plant of MSR. In this paper, in order to developing a system analysis code suitable for liquid fueled molten salt reactors, the point kinetics and thermo-hydraulic models as well as the numerical method in thermal–hydraulic transient code Reactor Excursion and Leak Analysis Program (RELAP5) developed at the Idaho National Engineering Laboratory (INEL) for the U.S. Nuclear Regulatory Commission (NRC) are extended and verified by Molten Salt Reactor Experiment (MSRE) experimental benchmarks. And then, four transient scenarios including the load demand change, the primary flow transient, the secondary flow transient and the reactivity transient of the Molten Salt Breeder Reactor (MSBR) are modeled and simulated so as to evaluate the performance of the reactor during the anticipated transient events using the extended RELAP5 code. The results indicate the extended RELAP5 code is effective and well suited to the liquid fueled molten salt reactor, and the MSBR has strong inherent safety characteristics because of its large negative reactivity coefficient. In the future, the extended RELAP5 code will be used to perform transient safety analysis for a liquid fueled thorium molten salt reactor named TMSR-LF developed by the Center

  6. Development and application of a system analysis code for liquid fueled molten salt reactors based on RELAP5 code

    International Nuclear Information System (INIS)

    Shi, Chengbin; Cheng, Maosong; Liu, Guimin

    2016-01-01

    Highlights: • New point kinetics and thermo-hydraulics models as well as a numerical method are added into RELAP5 code to be suitable for liquid fueled molten salt reactor. • The extended REALP5 code is verified by the experimental benchmarks of MSRE. • The different transient scenarios of the MSBR are simulated to evaluate performance during the transients. - Abstract: The molten salt reactor (MSR) is one of the six advanced reactor concepts declared by the Generation IV International Forum (GIF), which can be characterized by attractive attributes as inherent safety, economical efficiency, natural resource protection, sustainable development and nuclear non-proliferation. It is important to make system safety analysis for nuclear power plant of MSR. In this paper, in order to developing a system analysis code suitable for liquid fueled molten salt reactors, the point kinetics and thermo-hydraulic models as well as the numerical method in thermal–hydraulic transient code Reactor Excursion and Leak Analysis Program (RELAP5) developed at the Idaho National Engineering Laboratory (INEL) for the U.S. Nuclear Regulatory Commission (NRC) are extended and verified by Molten Salt Reactor Experiment (MSRE) experimental benchmarks. And then, four transient scenarios including the load demand change, the primary flow transient, the secondary flow transient and the reactivity transient of the Molten Salt Breeder Reactor (MSBR) are modeled and simulated so as to evaluate the performance of the reactor during the anticipated transient events using the extended RELAP5 code. The results indicate the extended RELAP5 code is effective and well suited to the liquid fueled molten salt reactor, and the MSBR has strong inherent safety characteristics because of its large negative reactivity coefficient. In the future, the extended RELAP5 code will be used to perform transient safety analysis for a liquid fueled thorium molten salt reactor named TMSR-LF developed by the Center

  7. Conversion tool for the LWR transient analysis code RELAP5 from the CDC version to the FACOM version

    International Nuclear Information System (INIS)

    Shinozawa, Naohisa; Fujisaki, Masahide; Makino, Mitsuhiro; Kondou, Kazuya; Ishiguro, Misako

    1987-01-01

    The LWR transient analysis code RELAP5 has been developed on the CDC-CYBER 176 at Idaho National Engineering Laboratory (INEL), the RELAP5 code has been often updated in order to extend the analyzing model and correct the errors. At Japan Atomic Energy Research Institute the code has been converted from the CDC version to the FACOM version and the converted code has been used. The conversion is the task which consumes a lot of time, because the code is large and there is the difference between CDC's machines and FACOM's ones. In order to convert the RELAP5 code automatically, the software tool has been developed. By using this tools the efficiency for converting the RELAP5 code has been improved. Productivity of the conversion is increased about 2.0 to 2.6 times by the tools in comparison with in manual. The procedure of conversion by using the tools and the option parameters of each tool are described. (author)

  8. Comparision of calculations for the ROSA-IV LSTF with RELAP5/MOD0 and RELAP5/MOD1 (cycle 1)

    International Nuclear Information System (INIS)

    Fineman, C.P.; Tanaka, Mitsugu; Tasaka, Kanji

    1982-03-01

    10% and 2.5% cold leg break analyses have been completed for the ROSA-IV Large Scale Test Facility (LSTF) with the RELAP5/MOD0 and RELAP5/MOD1, cycle 1, computer codes. Comparisons between the calculations were made to determine any differences in the results obtained from the two versions of RELAP5. Differences in the two calculations were found which can be attributed to changes in the flow regime maps and critical flow model. (author)

  9. RELAP5-3D developmental assessment: Comparison of version 4.2.1i on Linux and Windows

    Energy Technology Data Exchange (ETDEWEB)

    Bayless, Paul D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-06-01

    Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code, version 4.2i, compiled on Linux and Windows platforms. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions differ between the Linux and Windows versions.

  10. Simulation and verification studies of reactivity initiated accident by comparative approach of NK/TH coupling codes and RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Ud-Din Khan, Salah [Chinese Academy of Sciences, Hefei (China). Inst. of Plasma Physics; King Saud Univ., Riyadh (Saudi Arabia). Sustainable Energy Technologies Center; Peng, Minjun [Harbin Engineering Univ. (China). College of Nuclear Science and Technology; Yuntao, Song; Ud-Din Khan, Shahab [Chinese Academy of Sciences, Hefei (China). Inst. of Plasma Physics; Haider, Sajjad [King Saud Univ., Riyadh (Saudi Arabia). Sustainable Energy Technologies Center

    2017-02-15

    The objective is to analyze the safety of small modular nuclear reactors of 220 MWe power. Reactivity initiated accidents (RIA) were investigated by neutron kinetic/thermal hydraulic (NK/TH) coupling approach and thermal hydraulic code i.e., RELAP5. The results obtained by these approaches were compared for validation and accuracy of simulation. In the NK/TH coupling technique, three codes (HELIOS, REMARK, THEATRe) were used. These codes calculate different parameters of the reactor core (fission power, reactivity, fuel temperature and inlet/outlet temperatures). The data exchanges between the codes were assessed by running the codes simultaneously. The results obtained from both (NK/TH coupling) and RELAP5 code analyses complement each other, hence confirming the accuracy of simulation.

  11. Analyses for MARIA Research Reactor with RELAP/MOD3 code

    International Nuclear Information System (INIS)

    Szczurek, J.; Czerski, P.

    2004-01-01

    This paper deals with the application of the RELAP5/MOD3 code to the transient analyses for MARIA research reactor. Poland's MARIA Research Reactor is water and beryllium moderated, water-cooled reactor of a pool type with pressurized fuel channels containing concentric multi-tube assemblies of highly enriched uranium clad in aluminium. The RELAP5/MOD3 input data model includes the whole primary cooling circuit of the MARIA reactor. The model was qualified against the reactor data at steady state conditions and additionally against the existing reliable experimental data for a transient initiated by the reactor scram. The RELAP transient simulation was performed for loss of forced flow accidents including two scenarios with protected and unprotected (no scram) reactor core. Calculations allow estimating time margin for reactor scram initiation and reactivity feedbacks contribution to the results. (author)

  12. Simulation of single phase instability behaviour in a rectangular natural circulation loop using RELAP5/ MOD 3.2 computer code

    International Nuclear Information System (INIS)

    Sharma, Manish; Pilkhwal, D.S.; Vijayan, P.K.; Saha, D.; Sinha, R.K.

    2002-06-01

    Occurrence of instability in natural circulation loops can lead to problems in control and occurrence of critical heat flux (CHF) during low flow periods. Remaining within an identified stable zone operation is therefore desirable. Natural circulation loops can pass through an unstable zone during start-up and power raising. In the present work RELAPS / MOD 3.2 computer code has been used to simulate the unstable oscillatory behavior observed in a rectangular natural circulation loop having horizontal heater and horizontal cooler (HHHC) orientation. The results were compared with the experimental data. This report describes the nodalization scheme adopted tor this work and results of the analysis in detail. (author)

  13. Development of a Wrapper Object, TRelap, for RELAP5 Code for Use in Object Oriented Programs

    International Nuclear Information System (INIS)

    Lee, Young Jin

    2008-01-01

    TRelap object class has been developed to enable object oriented programming techniques to be used where functionality of the RELAP5 thermal hydraulic system analysis code is needed. The TRelap is an object front for Dynamic Link Library (DLL) manifestation of the Relap5 code, Relap5.dll. In making the Relap5.dll, the top most structure of the RELAP5 was altered to enable the external calling procedures to control and the access the memory. The alteration was performed in such a way to allow the entire 'fa' and the f tb' memory spaces to be accessible to the calling procedure. Thus, any variable contained within the 'fa' array such as the parameters for the components, volumes, junctions, and heat structures can be accessed by the external calling procedure through TRelap. Various methods and properties to control the RELAP5 calculation and to access and manipulate the variables are built into the TRelap to enable easy manipulation. As a verification effort, a simple program was written to demonstrate the capability of the TRelap

  14. RELAP5/MOD2 assessment at Babcock and Wilcox

    International Nuclear Information System (INIS)

    Nithianandan, C.K.; Shah, N.H.; Schomaker, R.J.; Turk, C.

    1986-01-01

    Babcock and Wilcox (B and W) has been working with the code developers at EG and G Idaho, Inc. and the NRC assessing the RELAP5/MOD2 computer code by simulating selected separate effects tests. The purpose of this B and W Owners Group-sponsored assessment was to evaluate RELAP5/MOD2 for use in design calculations for the MIST and OTIS integral system tests and in predicting pressurized water reactor (PWR) transients. B and W evaluated various versions of the code and made recommendations to improve code performance. As a result, the currently released version (Cycle 36.1) has been improved considerably over earlier versions. However, further refinements to some of the constitutive models may still be needed to further improve specific predictive capabilities of RELAP5/MOD2

  15. On RELAP5-simulated High Flux Isotope Reactor reactivity transients: Code change and application

    International Nuclear Information System (INIS)

    Freels, J.D.

    1993-01-01

    This paper presents a new and innovative application for the RELAP5 code (hereafter referred to as ''the code''). The code has been used to simulate several transients associated with the (presently) draft version of the High-Flux Isotope Reactor (HFIR) updated safety analysis report (SAR). This paper investigates those thermal-hydraulic transients induced by nuclear reactivity changes. A major goal of the work was to use an existing RELAP5 HFIR model for consistency with other thermal-hydraulic transient analyses of the SAR. To achieve this goal, it was necessary to incorporate a new self-contained point kinetics solver into the code because of a deficiency in the point-kinetics reactivity model of the Mod 2.5 version of the code. The model was benchmarked against previously analyzed (known) transients. Given this new code, four event categories defined by the HFIR probabilistic risk assessment (PRA) were analyzed: (in ascending order of severity) a cold-loop pump start; run-away shim-regulating control cylinder and safety plate withdrawal; control cylinder ejection; and generation of an optimum void in the target region. All transients are discussed. Results of the bounding incredible event transient, the target region optimum void, are shown. Future plans for RELAP5 HFIR applications and recommendations for code improvements are also discussed

  16. RELAP5 thermal-hydraulic analyses of overcooling sequences in a pressurized water reactor

    International Nuclear Information System (INIS)

    Bolander, M.A.; Fletcher, C.D.; Davis, C.B.; Kullberg, C.M.; Stitt, B.D.; Waterman, M.E.; Burtt, J.D.

    1984-01-01

    In support of the Pressurized Thermal Shock Integration Study, sponsored by the United States Nuclear Regulatory Commission, the Idaho National Engineering Laboratory has performed analyses of overcooling transients using the RELAP5/MOD1.6 and MOD2.0 computer codes. These analyses were performed for the H.B. Robinson Unit 2 pressurized water reactor, which is a Westinghouse 3-loop design plant. Results of the RELAP5 analyses are presented. The capabilities of the RELAP5 computer code as a tool for analyzing integral plant transients requiring a detailed plant model, including complex trip logic and major control systems, are examined

  17. An implicit steady-state initialization package for the RELAP5 computer code

    International Nuclear Information System (INIS)

    Paulsen, M.P.; Peterson, C.E.; Odar, F.

    1995-08-01

    A direct steady-state initialization (DSSI) method has been developed and implemented in the RELAP5 hydrodynamic analysis program. It provides a means for users to specify a small set of initial conditions which are then propagated through the remainder of the system. The DSSI scheme utilizes the steady-state form of the RELAP5 balance equations for nonequilibrium two-phase flow. It also employs the RELAP5 component models and constitutive model packages for wall-to-phase and interphase momentum and heat exchange. A fully implicit solution of the linearized hydrodynamic equations is implemented. An implicit coupling scheme is used to augment the standard steady-state heat conduction solution for steam generator use. It solves the primary-side tube region energy equations, heat conduction equations, wall heat flux boundary conditions, and overall energy balance equation as a coupled system of equations and improves convergence. The DSSI method for initializing RELAP5 problems to steady-state conditions has been compared with the transient solution scheme using a suite of test problems including; adiabatic single-phase liquid and vapor flow through channels with and without healing and area changes; a heated two-phase test bundle representative of BWR core conditions; and a single-loop PWR model

  18. SCDAP/RELAP5/MOD 3.1 code manual: MATPRO, A library of materials properties for Light-Water-Reactor accident analysis. Volume 4

    International Nuclear Information System (INIS)

    Hagrman, D.T.

    1995-06-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light -- water-reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, the core, fission products released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume, Volume IV, describes the material properties correlations and computer subroutines (MATPRO) used by SCDAP/RELAP5. formulation of the materials properties are generally semi-empirical in nature. The materials property subroutines contained in this document are for uranium, uranium dioxide, mixed uranium-plutonium dioxide fuel, zircaloy cladding, zirconium dioxide, stainless steel, stainless steel oxide, silver-indium-cadmium alloy, cadmium, boron carbide, Inconel 718, zirconium-uranium-oxygen melts, fill gas mixtures, carbon steel, and tungsten. This document also contains descriptions of the reaction and solution rate models needed to analyze a reactor accident

  19. RELAP5-3D User Problems

    Energy Technology Data Exchange (ETDEWEB)

    Riemke, Richard Allan

    2002-09-01

    The Reactor Excursion and Leak Analysis Program with 3D capability1 (RELAP5-3D) is a reactor system analysis code that has been developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the U. S. Department of Energy (DOE). The 3D capability in RELAP5-3D includes 3D hydrodynamics2 and 3D neutron kinetics3,4. Assessment, verification, and validation of the 3D capability in RELAP5-3D is discussed in the literature5,6,7,8,9,10. Additional assessment, verification, and validation of the 3D capability of RELAP5-3D will be presented in other papers in this users seminar. As with any software, user problems occur. User problems usually fall into the categories of input processing failure, code execution failure, restart/renodalization failure, unphysical result, and installation. This presentation will discuss some of the more generic user problems that have been reported on RELAP5-3D as well as their resolution.

  20. RELAP5 - a new tool for pressurized water reactor safety analysis

    International Nuclear Information System (INIS)

    Perneczky, L.

    1988-11-01

    The RELAP type pressurized water reactor safety system codes are used world wide for the loss of coolant accident analyses. In this paper the RELAP5, the advanced generation of the code family is presented. The relationship to RELAP4/mod6 version is discussed. The capability of the RELAP5/mod1-EUR version for small, medium and large break LOCA is investigated based on international user experience. (author) 30 refs

  1. Enhancement of safety analysis reliability for a CANDU-6 reactor using RELAP-CANDU/SCAN coupled code system

    International Nuclear Information System (INIS)

    Kim, Man Woong; Choi, Yong Seog; Sin, Chul; Kim, Hyun Koon; Kim, Hho Jung; Hwang, Su Hyun; Hong, In Seob; Kim, Chang Hyo

    2005-01-01

    In LOCA analysis of the CANDU reactor, the system thermal-hydraulic code, RELAP-CANDU, alone cannot predict the transient behavior accurately. Therefore, the best estimate neutronics and system thermal-hydraulic coupled code system is necessary to describe the transient behavior with higher accuracy and reliability. To perform on-line calculation of safety analysis for CANDU reactor, a coupled thermal hydraulics-neutronics code system was developed in such a way that the best-estimate thermal-hydraulic system code for CANDU reactor, RELAP-CANDU, is coupled with the full three-dimensional reactor core kinetic code

  2. System Simulation of Nuclear Power Plant by Coupling RELAP5 and Matlab/Simulink

    International Nuclear Information System (INIS)

    Meng Lin; Dong Hou; Zhihong Xu; Yanhua Yang; Ronghua Zhang

    2006-01-01

    Since RELAP5 code has general and advanced features in thermal-hydraulic computation, it has been widely used in transient and accident safety analysis, experiment planning analysis, and system simulation, etc. So we wish to design, analyze, verify a new Instrumentation And Control (I and C) system of Nuclear Power Plant (NPP) based on the best-estimated code, and even develop our engineering simulator. But because of limited function of simulating control and protection system in RELAP5, it is necessary to expand the function for high efficient, accurate, flexible design and simulation of I and C system. Matlab/Simulink, a scientific computation software, just can compensate the limitation, which is a powerful tool in research and simulation of plant process control. The software is selected as I and C part to be coupled with RELAP5 code to realize system simulation of NPPs. There are two key techniques to be solved. One is the dynamic data exchange, by which Matlab/Simulink receives plant parameters and returns control results. Database is used to communicate the two codes. Accordingly, Dynamic Link Library (DLL) is applied to link database in RELAP5, while DLL and S-Function is applied in Matlab/Simulink. The other problem is synchronization between the two codes for ensuring consistency in global simulation time. Because Matlab/Simulink always computes faster than RELAP5, the simulation time is sent by RELAP5 and received by Matlab/Simulink. A time control subroutine is added into the simulation procedure of Matlab/Simulink to control its simulation advancement. Through these ways, Matlab/Simulink is dynamically coupled with RELAP5. Thus, in Matlab/Simulink, we can freely design control and protection logic of NPPs and test it with best-estimated plant model feedback. A test will be shown to illuminate that results of coupling calculation are nearly the same with one of single RELAP5 with control logic. In practice, a real Pressurized Water Reactor (PWR) is

  3. Code option guideline improvement using comparisons of RELAP4/MOD6 with forced and gravity-feed reflood data. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T H; Fletcher, C D

    1978-09-01

    Improved guidelines are developed for the selection of RELAP4/MOD6 reflood heat transfer options. The development, involving modifications to the original guidelines, assessed the effect of those modifications on RELAP4/MOD6 data comparisons using previously analyzed reflood experiments. The report also presents an evaluation of the application of the revised guidelines. Data comparisons between RELAP4/MOD6, using the original and revised guidelines, and experimental data are presented for Semiscale and FLECHT, forced-feed reflood tests and Semiscale and FLECHT-SET gravity-feed reflood tests. Because a general improvement was evident in data comparisons using the revised guidelines, their use is recommended in future calculations.

  4. The preliminary thermal-hydraulic design of one superheated steam water cooled blanket concept based on RELAP5 and MELCOR codes - 15147

    International Nuclear Information System (INIS)

    Guo, Y.; Wang, G.; Cheng, Y.; Peng, C.

    2015-01-01

    Water Cooled Blanket (WCB) is very important in the concept design and energy transfer in future fusion power plant. One concept design of WCB is under computational testing. RELAP5 and MELCOR codes, which are mature and often used in nuclear engineering, are selected as simulation tools. The complex inner flow channels and heat sources are simplified according to its thermal-hydraulic characteristics. Then the nodal models for RELAP5 and MELCOR are built for approximating the concept design. The superheated steam scheme is analyzed by two codes separately under different power levels. After some adjustments of the inlet flow resistance coefficients of some flow channels, the reasonable stable conditions can be obtained. The stable fluid and wall temperature distributions and pressure drops are studied. The results of two codes are compared and some advices are given. (authors)

  5. Loss of coolant acident analyses on Osiris research reactor using the RELAP5 code

    International Nuclear Information System (INIS)

    Soares, Humberto Vitor; Costa, Antonella Lombardi; Lima, Claubia Pereira Bezerra; Veloso, Maria Auxiliadora Fortini

    2011-01-01

    RELAP5/MOD 3.3 code is widely used for thermal hydraulic studies of commercial nuclear power plants. However, several current investigations have shown that RELAP5 code can also be applied for thermal hydraulic analysis of nuclear research systems with good predictions. In this paper, a nodalization of the core and the most important components of the primary cooling system of the OSIRIS reactor developed for RELAP5 thermal hydraulic code are presented as well as results of steady state and transient simulations. OSIRIS has thermal power of 70 MW and it is an open pool type research reactor moderated and cooled by water. The OSIRIS reactor characteristics have been used as a base for the development of a model for the Multipurpose Brazilian Reactor (RMB). The aim of the present work is to investigate the behavior of the core during a loss of coolant accident and the possible damage of the fuel elements due an inadequate heat removal. Although the core coolant reached the saturation point due the large break, the fuel element conditions were out of the damage zone. (author)

  6. Assessment of RELAP5/MOD2 and RELAP5/MOD1-EUR codes on the basis of LOBI-MOD2 test results

    International Nuclear Information System (INIS)

    D'Auria, F.; Mazzini, M.; Oriolo, F.; Galassi, G.M.

    1989-10-01

    The present report deals with an overview of the application of RELAP5/MOD2 and RELAP5/MOD1-EUR codes to tests performed in the LOBI/MOD2 facility. The work has been carried out in the frame of a contract between Dipartimento di Costruzioni Meccaniche e Nucleari (DCMN) of Pisa University and CEC. The Universities of Roma, Pisa, Bologna and Palermo and the Polytechnic of Torino performed the post-test analysis of the LOBI experiment under the supervision of DCMN. In the report the main outcomes from the analysis of the LOBI experiments are given with the attempt to identify deficiencies in the modelling capabilities of the used codes

  7. Current algorithms used in reactor safety codes and the impact of future computer development on these algorithms

    International Nuclear Information System (INIS)

    Mahaffy, J.H.; Liles, D.R.; Woodruff, S.B.

    1985-01-01

    Computational methods and solution procedures used in the US Nuclear Regulatory Commission's reactor safety systems codes, Transient Reactor Analysis Code (TRAC) and Reactor Leak and Power Safety Excursion Code (RELAP), are reviewed. Methods used in TRAC-PF1/MOD1, including the stability-enhancing two-step (SETS) technique, which permits fast computations by allowing time steps larger than the material Courant stability limit, are described in detail, and the differences from RELAP5/MOD2 are noted. Developments in computing, including parallel and vector processing, and their applicability to nuclear reactor safety codes are described. These developments, coupled with appropriate numerical methods, make detailed faster-than-real-time reactor safety analysis a realistic near-term possibility

  8. Study of a loss of coolant accident of a PWR reactor through a Full Scope Simulator and computational code RELAP

    International Nuclear Information System (INIS)

    Soares, Alexandre de Souza

    2014-01-01

    The present paper proposes a study of a loss of coolant accident of a PWR reactor through a Full Scope Simulator and computational code RELAP. To this end, it considered a loss of coolant accident with 160 cm 2 breaking area in cold leg of 20 circuit of the reactor cooling system of nuclear power plant Angra 2, with the reactor operating in stationary condition, to 100% power. It considered that occurred at the same time the loss of External Power Supply and the availability of emergency cooling system was not full. The results obtained are quite relevant and with the possibility of being used in the planning of future activities, given that the construction of Angra 3 is underway and resembles the Angra 2. (author)

  9. SCDAP/RELAP5/MOD2 code manual

    International Nuclear Information System (INIS)

    Allison, C.M.; Johnson, E.C.

    1989-09-01

    The SCDAP/RELAP5 code has been developed for best-estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, the core, and the fission products and aerosols in the system during a severe accident transient as well as large and small break loss-of-coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. The modeling theory and associated numerical schemes are documented in Volumes I and II to acquaint the user with the modeling base and thus aid in effective use of the code

  10. LOCA analysis program RELAP4J for water cooled nuclear reactors

    International Nuclear Information System (INIS)

    Motizuki, Yooji; Sobajima, Makoto; Suzuki, Mitsuhiro; Soda, Kunihisa; Tasaka, Kanji.

    1978-02-01

    RELAP4J, a version of RELAP4-Mod2 based on the ROSA-I and II tests has the following alterations : discharge coefficient correlation in discharge flow calculation, Zaloudek's equation for subcooled discharge flow, sonic choke instead of Moody choke in high quality regions, Wilson's equation for bubble rising velocity, bubble rise model for counter-current flow, steady-state pressure distribution calculation, stabilized numerical integration and unit conversion from Ft-1b to MKS. With these alterations both practical and useful, the agreement between calculations and experiments is good and computer times are 1/5 -- 1/10 those without the numerical stability. (auth.)

  11. SCDAP/RELAP5/MOD 3.1 Code Manual: Developmental assessment. Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    Hohorst, J.K.; Johnsen, E.C. [eds.; Allison, C.M. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1995-06-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of Light Water Reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, the core, fission product released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume contains detailed code-to-data calculations performed using SCDAP/RELAP5/MOD3.1, as well as comparison calculations performed with earlier code versions. Results of full plant calculations which include Surry, TMI-2, and Browns Ferry are described. Results of a nodalization study, which accounted for both axial and radial nodalization of the core, are also reported.

  12. SCDAP/RELAP5/MOD 3.1 Code Manual: Developmental assessment. Volume 5

    International Nuclear Information System (INIS)

    Hohorst, J.K.; Johnsen, E.C.

    1995-06-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of Light Water Reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, the core, fission product released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume contains detailed code-to-data calculations performed using SCDAP/RELAP5/MOD3.1, as well as comparison calculations performed with earlier code versions. Results of full plant calculations which include Surry, TMI-2, and Browns Ferry are described. Results of a nodalization study, which accounted for both axial and radial nodalization of the core, are also reported

  13. Modelling of QUENCH-03 and QUENCH-06 Experiments Using RELAP/SCDAPSIM and ASTEC Codes

    Directory of Open Access Journals (Sweden)

    Tadas Kaliatka

    2014-01-01

    Full Text Available To prevent total meltdown of the uncovered and overheated core, the reflooding with water is a necessary accident management measure. Because these actions lead to the generation of hydrogen, which can cause further problems, the related phenomena are investigated performing experiments and computer simulations. In this paper, for the experiments of loss of coolant accidents, performed in Forschungszentrum Karlsruhe, QUENCH-03 and QUENCH-06 are modelled using RELAP5/SCDAPSIM and ASTEC codes. The performed benchmark allowed analysing different modelling features. The recommendations for the model development are presented.

  14. Uncertainty and sensitivity analysis in the scenario simulation with RELAP/SCDAP and MELCOR codes

    International Nuclear Information System (INIS)

    Garcia J, T.; Cardenas V, J.

    2015-09-01

    A methodology was implemented for analysis of uncertainty in simulations of scenarios with RELAP/SCDAP V- 3.4 bi-7 and MELCOR V-2.1 codes, same that are used to perform safety analysis in the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). The uncertainty analysis methodology chosen is a probabilistic method of type Propagation of uncertainty of the input parameters to the departure parameters. Therefore, it began with the selection of the input parameters considered uncertain and are considered of high importance in the scenario for its direct effect on the output interest variable. These parameters were randomly sampled according to intervals of variation or probability distribution functions assigned by expert judgment to generate a set of input files that were run through the simulation code to propagate the uncertainty to the output parameters. Then, through the use or ordered statistical and formula Wilks, was determined that the minimum number of executions required to obtain the uncertainty bands that include a population of 95% at a confidence level of 95% in the results is 93, is important to mention that in this method that number of executions does not depend on the number of selected input parameters. In the implementation routines in Fortran 90 that allowed automate the process to make the uncertainty analysis in transients for RELAP/SCDAP code were generated. In the case of MELCOR code for severe accident analysis, automation was carried out through complement Dakota Uncertainty incorporated into the Snap platform. To test the practical application of this methodology, two analyzes were performed: the first with the simulation of closing transient of the main steam isolation valves using the RELAP/SCDAP code obtaining the uncertainty band of the dome pressure of the vessel; while in the second analysis, the accident simulation of the power total loss (Sbo) was carried out with the Macarol code obtaining the uncertainty band for the

  15. Application of RELAP5/MOD3.1 code to the LOFT test L3-6

    International Nuclear Information System (INIS)

    Pylev, S.S.; Roginskaja, V.L.

    1998-02-01

    A calculation of LOFT Experiment L3-6, a small break equivalent to a 4-in diameter rupture in the cold leg of a four-loop commercial pressurized water reactor, has been performed to help validate RELAP5/MOD3.1 for this application. The version of the code to be used is SCDAP/RELAP5/MOD3.1.8d0. Three calculations were carried out in order to study the sensitivity to change break nozzle superheated discharge coefficient. Conducted comparative analysis of the LOFT L3-6 experiment shows on the whole a reasonable agreement between calculated data. Some discrepancies in the system pressure do not distort a picture of the transient. 6 refs

  16. Application of RELAP5/MOD3.1 code to the LOFT test L3-6

    Energy Technology Data Exchange (ETDEWEB)

    Pylev, S.S.; Roginskaja, V.L.

    1998-02-01

    A calculation of LOFT Experiment L3-6, a small break equivalent to a 4-in diameter rupture in the cold leg of a four-loop commercial pressurized water reactor, has been performed to help validate RELAP5/MOD3.1 for this application. The version of the code to be used is SCDAP/RELAP5/MOD3.1.8d0. Three calculations were carried out in order to study the sensitivity to change break nozzle superheated discharge coefficient. Conducted comparative analysis of the LOFT L3-6 experiment shows on the whole a reasonable agreement between calculated data. Some discrepancies in the system pressure do not distort a picture of the transient. 6 refs.

  17. A comparison of the steady-state facility in the RELAP-UK code with the CUSH code and with collant flow in the Winfrith SGHWR

    International Nuclear Information System (INIS)

    Roberts, H.A.; Smith, C.P.

    1976-02-01

    Provision of capability for performing steady-state calculations in RELAP-UK has led to the possibility of the wider use of this code for steady-state assessments of the behaviour of commercial systems with complicated circuit arrangements. In the studies discussed in this report, the first objective is to demonstrate the performance of the RELAP-UK code in a steady-state role, and to make comparisons with the CUSH code, and with measurements obtained on the Winfrith Steam-Generating Heavy Water Reactor. (U.K.)

  18. Modernization and restructuring of realistic thermal hydraulic system analysis code, RELAP5/MOD3.3.1.2

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Lee, Won Jae; Jeong, Jae Jun; Ha, Kwi Seok

    1998-01-01

    The code architecture entails the programming language and the code database. Various recent programming languages such as C, C ++ , Fortran 90, were considered as the candidate language for the modernization of RELAP5/MOD3.2.1.2. Among them, Fortran 90 was selected as a basic programming laguage for the modernization and restructuring of the code. Most of header file ( * .h) and equivalenced variables in RELAP5 have been replaced with members in the MODULE, which greatly enhance the code maintenance and readability. The FTB package is used for the dynamic memory management (DMM) of RELAP5. Although FTB DMM features are very successful, the use of FTB has been the obstacle in the maintenance of the code. It is difficult to understand and change the coding, and it requires a significant effort to find out index errors in large memory pools. With new features introduced in Fortran 90, it is possible to slove dynamic allocation problems within the standard features in an elegant, clear safe way. Each of FTB data blocks can be replaced by the suitably organized derived variables in MODULE and the standard DMM scheme. This DMM scheme provides the code flexibility which can save the memory requirements depending on the problem sizes without a extensive use of the complex FTB package. The current user's interface of the RELAP5 consists of a set of input file, output file, and restart/plot file. Many users complain that this interface is not user friendly. It was mainly caused by the text-oriented programming, namly console programming during the past many years. Now, windows programming has become popular in most areas of software development. Using this windows programming technique, the user friend freatures can be implemented. The Visual Fortran Quick Win run-time library helps to turn graphics programs into simple Windows applications. RELAP5 code has been re-compiled with the Quick Win feature, and the mask for user's dialog and graphical x-y plot were designed. This

  19. Analysis of different containment models for IRIS small break LOCA, using GOTHIC and RELAP5 codes

    International Nuclear Information System (INIS)

    Papini, Davide; Grgic, Davor; Cammi, Antonio; Ricotti, Marco E.

    2011-01-01

    Advanced nuclear water reactors rely on containment behaviour in realization of some of their passive safety functions. Steam condensation on containment walls, where non-condensable gas effects are significant, is an important feature of the new passive containment concepts, like the AP600/1000 ones. In this work the international reactor innovative and secure (IRIS) was taken as reference, and the relevant condensation phenomena involved within its containment were investigated with different computational tools. In particular, IRIS containment response to a small break LOCA (SBLOCA) was calculated with GOTHIC and RELAP5 codes. A simplified model of IRIS containment drywell was implemented with RELAP5 according to a sliced approach, based on the two-pipe-with-junction concept, while it was addressed with GOTHIC using several modelling options, regarding both heat transfer correlations and volume and thermal structure nodalization. The influence on containment behaviour prediction was investigated in terms of drywell temperature and pressure response, heat transfer coefficient (HTC) and steam volume fraction distribution, and internal recirculating mass flow rate. The objective of the paper is to preliminarily compare the capability of the two codes in modelling of the same postulated accident, thus to check the results obtained with RELAP5, when applied in a situation not covered by its validation matrix (comprising SBLOCA and to some extent LBLOCA transients, but not explicitly the modelling of large dry containment volumes). The option to include or not droplets in fluid mass flow discharged to the containment was the most influencing parameter for GOTHIC simulations. Despite some drawbacks, due, e.g. to a marked overestimation of internal natural recirculation, RELAP5 confirmed its capability to satisfactorily model the basic processes in IRIS containment following SBLOCA.

  20. SCDAP/RELAP5/MOD2 code manual

    International Nuclear Information System (INIS)

    Allison, C.M.; Johnson, E.C.

    1989-09-01

    The SCDAP/RELAP5 code has been developed for best-estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, the core, and the fission products and aerosols in the system during a severe accident transient as well as large and small break loss-of-coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. The modeling theory and associated numerical schemes are documented in Volumes I and in this document, Volume II, to acquaint the user with the modeling base and thus aid in effective use of the code. 135 refs., 48 figs., 8 tabs

  1. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Volume I. RELAP4/MOD5 description. [PWR and BWR

    Energy Technology Data Exchange (ETDEWEB)

    1976-09-01

    RELAP4 is a computer program written in FORTRAN IV for the digital computer analysis of nuclear reactors and related systems. It is primarily applied in the study of system transient response to postulated perturbations such as coolant loop rupture, circulation pump failure, power excursions, etc. The program was written to be used for water-cooled (PWR and BWR) reactors and can be used for scale models such as LOFT and SEMISCALE. Additional versatility extends its usefulness to related applications, such as ice condenser and containment subcompartment analysis. Specific options are available for reflood (FLOOD) analysis and for the NRC Evaluation Model.

  2. RELAP5/MOD2 Overview and Developmental. Assessment Results from TMl-1 Plant Transient Analysis

    International Nuclear Information System (INIS)

    Lin, J. C.; Tsai, C. C.; Ransom, V. H.; Johnsen, G. W.

    2013-01-01

    RELAP5/MOD2 is a new version of the RELAP5 thermal-hydraulic computer code containing improved modeling features that provide a generic capability for pressurized water reactor transient simulation. The objective of this paper is to provide code users with an overview of the code and to report developmental assessment results obtained from a Three Mile Island Unit One plant transient analysis. The assessment shows that the injection of highly sub-cooled water into a high-pressure primary coolant system does not cause unphysical results or pose a problem for RELAP5/MOD2. (author)

  3. The CAIN computer code for the generation of MABEL input data sets: a user's manual

    International Nuclear Information System (INIS)

    Tilley, D.R.

    1983-03-01

    CAIN is an interactive FORTRAN computer code designed to overcome the substantial effort involved in manually creating the thermal-hydraulics input data required by MABEL-2. CAIN achieves this by processing output from either of the whole-core codes, RELAP or TRAC, interpolating where necessary, and by scanning RELAP/TRAC output in order to generate additional information. This user's manual describes the actions required in order to create RELAP/TRAC data sets from magnetic tape, to create the other input data sets required by CAIN, and to operate the interactive command procedure for the execution of CAIN. In addition, the CAIN code is described in detail. This programme of work is part of the Nuclear Installations Inspectorate (NII)'s contribution to the United Kingdom Atomic Energy Authority's independent safety assessment of pressurized water reactors. (author)

  4. Peer review of RELAP5/MOD3 documentation

    International Nuclear Information System (INIS)

    Craddick, W.G.

    1993-01-01

    A peer review was performed on a portion of the documentation of the RELAP5/MOD3 computer code. The review was performed in two phases. The first phase was a review of Volume 3, Developmental Assessment problems, and Volume 4, Models and Correlations. The reviewers for this phase were Dr. Peter Griffith, Dr. Yassin Hassan, Dr. Gerald S. Lellouche, Dr. Marino di Marzo and Mr. Mark Wendel. The reviewers recommended a number of improvements, including using a frozen version of the code for assessment guided by a validation plan, better justification for flow regime maps and extension of models beyond their data base. The second phase was a review of Volume 6, Quality Assurance of Numerical Techniques in RELAP5/MOD3. The reviewers for the second phase were Mr. Mark Wendel and Dr. Paul T. Williams. Recommendations included correction of numerous grammatical and typographical errors and better justification for the use of Lax's Equivalence Theorem

  5. RELAP-7 Software Verification and Validation Plan - Requirements Traceability Matrix (RTM) Part 2: Code Assessment Strategy, Procedure, and RTM Update

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jun Soo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Choi, Yong Joon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Smith, Curtis Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-09-01

    This document addresses two subjects involved with the RELAP-7 Software Verification and Validation Plan (SVVP): (i) the principles and plan to assure the independence of RELAP-7 assessment through the code development process, and (ii) the work performed to establish the RELAP-7 assessment plan, i.e., the assessment strategy, literature review, and identification of RELAP-7 requirements. Then, the Requirements Traceability Matrices (RTMs) proposed in previous document (INL-EXT-15-36684) are updated. These RTMs provide an efficient way to evaluate the RELAP-7 development status as well as the maturity of RELAP-7 assessment through the development process.

  6. COMPUTATION FORMAT computer codes X4TOC4 and PLOTC4. Implementing and Testing on a Personal Computer

    International Nuclear Information System (INIS)

    McLaughlin, P.K.

    1987-05-01

    This document describes the contents of the diskette containing the COMPUTATION FORMAT codes X4TOC4 and PLOTC4 by D.E. Cullen, and example data for use in implementing and testing these codes on a Personal Computer of the type IBM-PC/AT. Upon request the codes are available from the IAEA Nuclear Data Section, free of charge, on a single diskette. (author)

  7. Angra 2 small break LOCA flow regime identification through RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Marcelo da Silva; Sabundjian, Gaiane; Belchior Junior, Antonio; Andrade, Delvonei Alves de; Torres, Walmir Maximo; Conti, Thadeu das Neves; Macedo, Luiz Alberto; Umbehaun, Pedro Ernesto; Mesquita, Roberto Navarro de; Masotti, Paulo Henrique Ferraz, E-mail: msrocha@ipen.br, E-mail: gdjian@ipen.br, E-mail: abelchior@ipen.br, E-mail: delvonei@ipen.br, E-mail: wmtorres@ipen.br, E-mail: tnconti@ipen.br, E-mail: lamacedo@ipen.br, E-mail: umbehaun@ipen.br, E-mail: s, E-mail: rnavarro@ipen.br, E-mail: pmasotti@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    The purpose of this paper is to identify the flow regimes in the core of Angra 2 nuclear reactor with RELAP5/MOD3.2.gamma code (RELAP5, 2001). The postulated accident is the loss of coolant through a small break in the primary circuit (SBLOCA), which is described in Chapter 15 of the Final Safety Analysis Report of Angra 2 - FSAR (ETN, 2006). As the primary circuit pressure decreases due to the loss of coolant, several alternating two phase flow regimes are established in the primary circuit. This paper analyses the coolant two-phase flow behavior in the nuclear reactor core during the postulated accident. (author)

  8. Integrated analysis for a small break LOCA in the IRIS reactor using MELCOR and RELAP5 codes

    International Nuclear Information System (INIS)

    Del Nevo, A.; Manfredini, A.; Oriolo, F.; Paci, S.; Oriani, L.

    2004-01-01

    The pressurized light water cooled, medium power (1000 MWt) IRIS (International Reactor Innovative and Secure) has been under development for four years by an international consortium of over 21 organizations from ten countries. The plant conceptual design was completed in 2001 and the preliminary design is nearing completion. The pre-application licensing process with NRC started in October, 2002 and IRIS is one of the designs considered by US utilities as part of the ESP (Early Site Permit) process. This paper's focus is on the use of well known computer codes for integrated (reactor vessel and containment) calculations of the IRIS response to a small break loss of coolant accident (LOCA). In IRIS, large break LOCA events are eliminated by the use of a layout configuration in which the reactor vessel contains all the reactor coolant system components including the core, control rod drive mechanisms, pressurizer, steam generators, and coolant pumps. Thus the IRIS configuration has no large loop piping; also, no pipes with a diameter greater than 0.1 meters are part of the reactor coolant system boundary. For small break LOCAs, IRIS features an innovative mitigation approach that is based on maintaining coolant inventory rather than designing high and low pressure injection systems to provide makeup coolant to the reactor to maintain core cooling. The novel IRIS approach requires development of evaluation models that are different from those used for the current generation of pressurized water reactors. An analysis of small break LOCAs for IRIS is documented in two companion papers, and has been developed using a preliminary evaluation model based on the explicit coupling of the RELAP5 and GOTHIC codes. The objective of this paper is to compare the results obtained via the coupled RELAP/GOTHIC code with different computational tools. A reference case from the preliminary IRIS safety assessment was selected, and the same small break LOCA sequence is analyzed using

  9. Preprocessor for RELAP5 code, nuclear reactor thermal hydraulics accident analysis program, using Microsoft MS-EXCEL tool

    International Nuclear Information System (INIS)

    Biaty, Patricia Andrea Paladino; Sabundjian, Gaiane

    2005-01-01

    The thermal hydraulic study in accidents and transients analyses in nuclear power plants is realized with some special tools. These programs use the best estimate analyses and have been developed to simulate accidents and transients in Pressurized Water Reactors (PWR) and auxiliary systems. The RELAP5 code has been used as tool to licensing the nuclear facilities in our country, which is the objective of this study. The main problem when RELAP5 code is used is a lot of information necessary to simulate thermal hydraulic accidents. Moreover, there is the necessity of a reasonable amount of mathematical operations to calculation of the geometry of the components existents. Therefore, in order to facilitate the manipulation of this information, it is necessary the developing a friendly preprocessor for attainment of the mathematical calculations for RELAP5 code. One of the tools used for some of these calculations is the MS-EXCEL, which will be used in this work. (author)

  10. RELAP5/MOD2 development

    International Nuclear Information System (INIS)

    Miller, C.S.

    1986-01-01

    Status of the RELAP5/MOD2 computer code is discussed. While the code is undergoing international assessment, emphasis is on user support and code maintenance with modifications allowed only for error correction and user convenience improvements. User support discussed is the response to user inquiries, maintenance of manuals and the implementation of a PC based newletter service. The major 1986 user convenience improvement is the self-initialization option. The method is discussed and examples for PWR ''U tube'' and ''once through'' plants are illustrated. Future plans are also outlined

  11. RELAP5/MOD2 development

    International Nuclear Information System (INIS)

    Miller, C.S.

    1987-01-01

    Status of the RELAP5/MOD2 computer code is discussed. While the code is undergoing international assessment, emphasis is on user support and code maintenance with modifications allowed only for error correction and user convenience improvements. User support discussed is the response to user inquiries, maintenance of manuals and the implementation of a PC based newsletter service. The major 1986 user convenience improvement is the self-initialization option. The method is discussed and examples for PWR U tube and once through plants are illustrated. Future plans are also outlined

  12. RELAP5/MOD3 code manual: Summaries and reviews of independent code assessment reports. Volume 7, Revision 1

    International Nuclear Information System (INIS)

    Moore, R.L.; Sloan, S.M.; Schultz, R.R.; Wilson, G.E.

    1996-10-01

    Summaries of RELAP5/MOD3 code assessments, a listing of the assessment matrix, and a chronology of the various versions of the code are given. Results from these code assessments have been used to formulate a compilation of some of the strengths and weaknesses of the code. These results are documented in the report. Volume 7 was designed to be updated periodically and to include the results of the latest code assessments as they become available. Consequently, users of Volume 7 should ensure that they have the latest revision available

  13. RELAP5-3D code validation of RBMK-1500 reactor reactivity measurement transients

    International Nuclear Information System (INIS)

    Kaliatka, Algirdas; Bubelis, Evaldas; Uspuras, Eugenijus

    2003-01-01

    This paper deals with the modeling of transients taking place during the measurements of the void and fast power reactivity coefficients performed at Ignalina NPP. The simulation of these transients was performed using RELAP5-3D code model of RBMK-1500 reactor. At the Ignalina NPP void and fast power reactivity coefficients are measured on a regular basis and, based on the total reactor power, reactivity, control and protection system control rods positions and the main circulation circuit parameter changes during the experiments, the actual values of these reactivity coefficients are determined. Following the simulation of the two above mentioned transients with RELAP5-3D code, a conclusion was made that the obtained calculation results demonstrate reasonable agreement with Ignalina NPP measured data. Behaviors of the separate MCC thermal-hydraulic parameters as well as physical processes are predicted reasonably well to the real processes, occurring in the primary circuit of RBMK-1500 reactor. The calculated reactivity and the total reactor core power behavior in time are also in reasonable agreement with the measured plant data. Despite of the small differences, RELAP5-3D code predicts reactivity and the total reactor core power behavior during the transients in a reasonable manner. Reasonable agreement of the measured and the calculated total reactor power change in time demonstrates the correct modeling of the neutronic processes taking place in RBMK-1500 reactor core

  14. Assessment of RELAP5/Mod3 system thermal hydraulic code using power test data of a BWR6 reactor

    International Nuclear Information System (INIS)

    Lee, M.; Chiang, C.S.

    1997-01-01

    The power test data of Kuosheng Nuclear Power Plant were used to assess RELAP5/Mod3 system thermal hydraulic analysis code. The plant employed a General Electric designed Boiling Water Reactor (BWR6) with rated power of 2894 MWth. The purpose of the assessment is to verify the validity of the plant specific RELAP5/Mod3 input deck for transient analysis. The power tests considered in the assessment were 100% power generator load rejection, the closure of main steam isolation valves (MSIVs) at 96% power, and the trip of recirculation pumps at 68% power. The major parameters compared in the assessment were steam dome pressure, steam flow rate, core flow rate, and downcomer water level. The comparisons of the system responses predicted by the code and the power test data were reasonable which demonstrated the capabilities of the code and the validity of the input deck. However, it was also identified that the separator model of the code may cause energy imbalance problem in the transient calculation. In the assessment, the steam separators were modeled using time-dependent junctions. In the approach, a complete separation of steam and water was predicted. The system responses predicted by RELAP5/Mod3 code were also compared with those from the calculations of RETRAN code. When these results were compared with the power test data, the predictions of the RETRAN code were better than those of RELAP5/Mod3. In the simulation of 100% power generator load rejection, it was believed that the difference in the steam separator model of these two codes was one of the reason of the difference in the prediction of power test data. The predictions of RELAP/Mod3 code can also be improved by the incorporation of one-dimensional kinetic model. There was also some margin for the improvement of the input related to the feedwater control system. (author)

  15. Summary description of the RELAP5 Koeberg-1 simulation model

    International Nuclear Information System (INIS)

    D'Arcy, A.J.

    1990-11-01

    The main features of the RELAP5 code and the model are summarized. The model has been quality-assured in accordance with a QA programme used in the Reactor Theory Group of the Atomic Energy Corporation of SA Ltd. The RELAP5 code is based on a non-homogeneous, non-equilibrium model for the two-phase system that is solved by a fast, partially implicit numerical scheme. The objective of the development effort from the outset has been to produce a code that includes important first-order effects necessary for accurate prediction of system transients, but is sufficiently simple and cost-effective so that parametric or sensitivity studies are possible. The code includes many generic component models from which general systems can be simulated. Special process models are included for effects such as form losses, flow at an abrupt area change, branching, choked flow, boron tracking and a non-condensible gas. The RELAP5 modelling and computational aspects covered are: hydrodynamic models, constitutive package, special process models, and user conveniences. 25 tabs., 8 figs., 17 refs

  16. Evaluation on operation of liquid relief valves for steam line break accidents by RELAP5/CANDU+ code

    International Nuclear Information System (INIS)

    Yang, C. Y.; Bang, Y. S.; Kim, H. J.

    2001-01-01

    A development of RELAP5/CANDU+ code for regulatory audits of accident analysis of CANDU nuclear power plants is on progress. This paper is undertaken in a procedure of a verification and validation for RELAP5/CANDU+ code by analyzing main steam line break accidents of WS 2/3/4. Following the ECC injection in sequence of the steam line breaks, the mismatch in heat transfer between the primary and the secondary systems makes pressure of the primary system instantly peaked to the open setpoint of liquid relief valves. The event sequence follows the result of WS 2/3/4 FSAR, but there is a difference in pressure transient after ECC injection. Sensitivity analysis for main factors dependent on the peak pressure such as control logics of liquid relief valves. ECC flow path and feedwater flow is performed. Because the pressure increase is continued for a long time and its peaking is high, open and close of the liquid relief valves are repeated several times, which is obviously different from those of WS 2/3/4 FSAR. As a result, it is evaluated that conservative modeling for the above variables is required in the analysis

  17. The TE coupled RELAP5/PANTHER/COBRA code package and methodology for integrated PWR accident analysis

    International Nuclear Information System (INIS)

    Schneidesch, Christophe R.; Zhang, Jinzhao; Ammirabile, Luca; Dalleur, Jean-Paul

    2006-01-01

    At Tractebel Engineering (TE), a dynamic coupling has been developed between the best estimate thermal hydraulics system code RELAP5 and the 3-dimensional neutronics code PANTHER via the transient analysis code linkage program TALINK. An interface between PANTHER and the subchannel core thermal-hydraulic analysis code COBRA 3C has been established for on-line calculation of the Departure from Nucleate Boiling Ratio (DNBR). In addition to the standard RELAP5-PANTHER coupling, the fully dynamic coupling of the RELAP5/PANTHER/COBRA3C-TE code package can be activated for evaluation purposes in which the PANTHER close-channel thermal-hydraulics module is replaced by the COBRA3C-TE with cross flow modelling and extended T-H flow conditions capabilities. The qualification of the RELAP5-PANTHER coupling demonstrated the robustness achieved by the combined 3-D neutron kinetics/system T-H code package for transient simulations. The coupled TE code package has been approved by the Belgian Safety Authorities and is used at TE for analyzing asymmetric PWR accidents with strong core-system interactions. In particular, the TE coupled code package was first used to develop a main steam line break in hot shutdown conditions (SLBHZP) accident analysis methodology based on the TE deterministic bounding approach. This methodology has been reviewed and accepted by the Belgian Safety Authorities for specific applications. Those specific applications are related to the power up-rate and steam generator replacement project of the Doel 2 plant or to the Tihange-3 SLB accident re-analysis. A coupled feedwater line break (FLB) accident analysis methodology is currently being reviewed for application approval. The results of coupled thermal-hydraulic and neutronic analysis of SLB and FLB show that there exist important margins in the traditional final safety analysis report (FSAR) accident analysis. Those margins can be used to increase the operational flexibility of the plants. Moreover, the

  18. The TE coupled RELAP5/PANTHER/COBRA code package and methodology for integrated PWR accident analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schneidesch, Christophe R.; Zhang, Jinzhao; Ammirabile, Luca; Dalleur, Jean-Paul [Suez-Tractebel Engineering, Avenue Ariane 7, B-1200 Brussels (Belgium)

    2006-07-01

    At Tractebel Engineering (TE), a dynamic coupling has been developed between the best estimate thermal hydraulics system code RELAP5 and the 3-dimensional neutronics code PANTHER via the transient analysis code linkage program TALINK. An interface between PANTHER and the subchannel core thermal-hydraulic analysis code COBRA 3C has been established for on-line calculation of the Departure from Nucleate Boiling Ratio (DNBR). In addition to the standard RELAP5-PANTHER coupling, the fully dynamic coupling of the RELAP5/PANTHER/COBRA3C-TE code package can be activated for evaluation purposes in which the PANTHER close-channel thermal-hydraulics module is replaced by the COBRA3C-TE with cross flow modelling and extended T-H flow conditions capabilities. The qualification of the RELAP5-PANTHER coupling demonstrated the robustness achieved by the combined 3-D neutron kinetics/system T-H code package for transient simulations. The coupled TE code package has been approved by the Belgian Safety Authorities and is used at TE for analyzing asymmetric PWR accidents with strong core-system interactions. In particular, the TE coupled code package was first used to develop a main steam line break in hot shutdown conditions (SLBHZP) accident analysis methodology based on the TE deterministic bounding approach. This methodology has been reviewed and accepted by the Belgian Safety Authorities for specific applications. Those specific applications are related to the power up-rate and steam generator replacement project of the Doel 2 plant or to the Tihange-3 SLB accident re-analysis. A coupled feedwater line break (FLB) accident analysis methodology is currently being reviewed for application approval. The results of coupled thermal-hydraulic and neutronic analysis of SLB and FLB show that there exist important margins in the traditional final safety analysis report (FSAR) accident analysis. Those margins can be used to increase the operational flexibility of the plants. Moreover, the

  19. Post-test analysis of PIPER-ONE PO-IC-2 experiment by RELAP5/MOD3 codes

    International Nuclear Information System (INIS)

    Bovalini, R.; D'Auria, F.; Galassi, G.M.; Mazzini, M.

    1996-11-01

    RELAP5/MOD3.1 was applied to the PO-IC-2 experiment performed in PIPER-ONE facility, which has been modified to reproduce typical isolation condenser thermal-hydraulic conditions. RELAP5 is a well known code widely used at the University of Pisa during the past seven years. RELAP5/MOD3.1 was the latest version of the code made available by the Idaho National Engineering Laboratory at the time of the reported study. PIPER-ONE is an experimental facility simulating a General Electric BWR-6 with volume and height scaling ratios of 1/2,200 and 1./1, respectively. In the frame of the present activity a once-through heat exchanger immersed in a pool of ambient temperature water, installed approximately 10 m above the core, was utilized to reproduce qualitatively the phenomenologies expected for the Isolation Condenser in the simplified BWR (SBWR). The PO-IC-2 experiment is the flood up of the PO-SD-8 and has been designed to solve some of the problems encountered in the analysis of the PO-SD-8 experiment. A very wide analysis is presented hereafter including the use of different code versions

  20. Investigation of 3D spatial effect on point kinetics estimation of the thermal hydraulics code RELAP for the analysis of MSLB accident of KK-NP

    International Nuclear Information System (INIS)

    Bera, S.; Pradhan, S.K.; Dubey, S.K.; Gupta, S.K.

    2011-01-01

    In general safety analyses of design basis accident of NPPs are being carried out using system thermal hydraulics code like RELAP. In RELAP, power is calculated based on point kinetics approximation, which virtually ignores the space and energy dependence of neutron flux. To include the space and energy dependence of neutron flux, three-dimensional neutronics code TRIHEXFA has been externally coupled with RELAP through interface program, TRIHEXFA-RELAP Interface Program (TRIP). Calculation methodology of TRIP program is based on adiabatic approximation. In the adiabatic approximation the neutron flux is being factored into spatial and amplitude part. Spatial part of flux is slowly varying with time whereas amplitude part is strongly varying function. The RELAP controls the transient time steps. Transient time is divided into several major and minor time steps. Minor time step is the sub-step of major time step. Thermal hydraulics and neutronics data are exchanged at each major time step. Spatial part of neutron flux has been updated at each major time step using TRIHEXFA code. But amplitude part of the neutron flux is calculated at each minor time step using RELAP code. Convergence of results of the coupled code, TRIP has been checked through coupling time step descritization study. This study determines the minimum coupling time step. Transient concerning VVER-1000 Main Steam Line Break, MSLB has been considered to investigate the space-time effect on point kinetics. MSLB occurs as a consequence of the rupture of one steam line upstream of main steam line isolation valves. Reference design and data from Kudankulam Nuclear Power Plant (KK-NPP) are used for the analysis. From this investigation it is found that TRIP significantly overestimates the maximum reactor power against uncoupled RELAP result. The time of scram also occur six seconds earlier in TRIP calculation compared to the RELAP. This exercise has also shown a proof of principle that coupling 3D

  1. Simulation of the OECD Main-Steam-Line-Break Benchmark Exercise 3 Using the Coupled RELAP5/PANTHER Codes

    International Nuclear Information System (INIS)

    Schneidesch, Christophe R.; Zhang Jinzhao

    2004-01-01

    The RELAP5 best-estimate thermal-hydraulic system code has been coupled with the PANTHER three-dimensional neutron kinetics code via the TALINK dynamic data exchange control and processing tool. The coupled RELAP5/PANTHER code package has been qualified and will be used at Tractebel Engineering (TE) for analyzing asymmetric pressurized water reactor (PWR) accidents with strong core-system interactions. The Organization for Economic Cooperation and Development/U.S. Nuclear Regulatory Commission PWR main-steam-line-break benchmark problem was analyzed as part of the qualification efforts to demonstrate the capability of the coupled code package of simulating such transients. This paper reports the main results of TE's contribution to the benchmark Exercise 3

  2. Analysis of the VVER-440 reactor steam generator secondary side with the RELAP5/MOD3 code

    International Nuclear Information System (INIS)

    Tuunanen, J.

    1993-01-01

    Nuclear Engineering Laboratory of the Technical Research Centre of Finland has widely used RELAP5/MOD2 and -MOD3 codes to simulate horizontal steam generators. Several models have been developed and successfully used in the VVER-safety analysis. Nevertheless, the models developed have included only rather few nodes in the steam generator secondary side. The secondary side has normally been divided into about 10 to 15 nodes. Since the secondary side at the steam generators of VVER-440 type reactors consists of a rather large water pool, these models were only roughly capable to predict secondary side flows. The paper describes an attempt to use RELAP5/MOD3 code to predict secondary side flows in a steam generator of a VVER-440 reactor. A 2D/3D model has been developed using RELAP5/MOD3 codes cross-flow junctions. The model includes 90 volumes on the steam generator secondary side. The model has been used to calculate steady state flow conditions in the secondary side of a VVER-440 reactor steam generator. (orig.) (1 ref., 9 figs., 2 tabs.)

  3. Application of the coupled Relap5/Panther codes for PWR steam. Line break accident analysis

    International Nuclear Information System (INIS)

    Guisset, J.-P.; Bosso, S.; Charlier, A.; Delhaye, X.; Ergo, O.; Ouliddren, K.; Schneidesch, C.; Zhang, J.

    2001-01-01

    A dynamic coupling between the existing 1-dimensional thermal-hydraulics system code RELAP5 and the 3-dimensional neutronics code PANTHER is applied via the transient analysis code linkage program TALINK. An interface between PANTHER and the subchannel thermal-hydraulic analysis code COBRA 3C allows direct evaluation of the Departure from Nucleate Boiling Ratio in parallel with the coupled PANTHER/RELAP5 simulation. The coupled codes are applied to develop a Final Safety Analysis Report (FSAR) accident analysis methodology for the major Steam Line Break (SLB) accident at hot zero power in a typical three-loop pressurised water reactor. In this methodology, the uncertainties related to the plant, core thermal-hydraulic and neutronic parameters are combined in a deterministic bounding approach based on sensitivity studies. The results of coupled thermal-hydraulic and neutronic analysis of SLB are presented and discussed. It is shown that there exists an important margin in the traditional FSAR accident analysis for SLB, which can be attributed by the conservatism's introduced by de-coupling the plant sub-systems. (author)

  4. Application of the coupled Relap5/Panther codes for PWR steam. Line break accident analysis

    Energy Technology Data Exchange (ETDEWEB)

    Guisset, J.-P.; Bosso, S.; Charlier, A.; Delhaye, X.; Ergo, O.; Ouliddren, K.; Schneidesch, C.; Zhang, J. [Tractebel Energy Engineering, Brussels (Belgium)

    2001-07-01

    A dynamic coupling between the existing 1-dimensional thermal-hydraulics system code RELAP5 and the 3-dimensional neutronics code PANTHER is applied via the transient analysis code linkage program TALINK. An interface between PANTHER and the subchannel thermal-hydraulic analysis code COBRA 3C allows direct evaluation of the Departure from Nucleate Boiling Ratio in parallel with the coupled PANTHER/RELAP5 simulation. The coupled codes are applied to develop a Final Safety Analysis Report (FSAR) accident analysis methodology for the major Steam Line Break (SLB) accident at hot zero power in a typical three-loop pressurised water reactor. In this methodology, the uncertainties related to the plant, core thermal-hydraulic and neutronic parameters are combined in a deterministic bounding approach based on sensitivity studies. The results of coupled thermal-hydraulic and neutronic analysis of SLB are presented and discussed. It is shown that there exists an important margin in the traditional FSAR accident analysis for SLB, which can be attributed by the conservatism's introduced by de-coupling the plant sub-systems. (author)

  5. Developmental assessment of RELAP5/MOD3 code against ROSA-IV/TPTF horizontal two-phase flow experiments

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Asaka, Hideaki; Anoda, Yoshinari; Ishiguro, Misako; Tasaka, Kanji; Mimura, Yuichi; Nemoto, Toshiyuki.

    1990-03-01

    A developmental version of the RELAP5/Mod3 code (as of June 1989) was assessed for accuracy using experimental data taken for high-pressure (7MPa) steam-water two-phase flow in a large-diameter (0.18 m) horizontal-pipe test section of the ROSA-IV Two-Phase Flow Test Facility (TPTF). The agreement between the measured and calculated test section void fractions was much better than that for the previous generation of RELAP5 (MOD2). The improvement was achieved primarily due to the code changes with respect to the flow stratification criterion and interfacial-drag calculation scheme. (author)

  6. Application of NEA/CSNI standard problem 3 (blowdown and flow reversal in the IETA-1 rig) to the validation of the RELAP-UK Mk IV code

    International Nuclear Information System (INIS)

    Bryce, W.M.

    1977-10-01

    NEA/CSNI Standard Problem 3 consists of the modelling of an experiment on the IETI-1 rig, in which there is initially flow upwards through a feeder, heated section and riser. The inlet and outlet are then closed and a breach opened at the bottom so that the flow reverses and the rig depressurises. Calculations of this problem by many countries using several computer codes have been reported and show a wide spread of results. The purpose of the study reported here was the following. First, to show the sensitivity of the calculation of Standard Problem 3. Second, to perform an ab initio best estimate calculation using the RELAP-UK Mark IV code with the standard recommended options, and third, to use the results of the sensitivity study to show where tuning of the RELAP-UK Mark IV recommended model options was required. This study has shown that the calculation of Standard Problem 3 is sensitive to model assumptions and that the use of the loss-of-coolant accident code RELAP-UK Mk IV with the standard recommended model options predicts the experimental results very well over most of the transient. (U.K.)

  7. Verification of thermal-hydraulic computer codes against standard problems for WWER reflooding

    International Nuclear Information System (INIS)

    Alexander D Efanov; Vladimir N Vinogradov; Victor V Sergeev; Oleg A Sudnitsyn

    2005-01-01

    Full text of publication follows: The computational assessment of reactor core components behavior under accident conditions is impossible without knowledge of the thermal-hydraulic processes occurring in this case. The adequacy of the results obtained using the computer codes to the real processes is verified by carrying out a number of standard problems. In 2000-2003, the fulfillment of three Russian standard problems on WWER core reflooding was arranged using the experiments on full-height electrically heated WWER 37-rod bundle model cooldown in regimes of bottom (SP-1), top (SP-2) and combined (SP-3) reflooding. The representatives from the eight MINATOM's organizations took part in this work, in the course of which the 'blind' and posttest calculations were performed using various versions of the RELAP5, ATHLET, CATHARE, COBRA-TF, TRAP, KORSAR computer codes. The paper presents a brief description of the test facility, test section, test scenarios and conditions as well as the basic results of computational analysis of the experiments. The analysis of the test data revealed a significantly non-one-dimensional nature of cooldown and rewetting of heater rods heated up to a high temperature in a model bundle. This was most pronounced at top and combined reflooding. The verification of the model reflooding computer codes showed that most of computer codes fairly predict the peak rod temperature and the time of bundle cooldown. The exception is provided by the results of calculations with the ATHLET and CATHARE codes. The nature and rate of rewetting front advance in the lower half of the bundle are fairly predicted practically by all computer codes. The disagreement between the calculations and experimental results for the upper half of the bundle is caused by the difficulties of computational simulation of multidimensional effects by 1-D computer codes. In this regard, a quasi-two-dimensional computer code COBRA-TF offers certain advantages. Overall, the closest

  8. Review of solution approach, methods, and recent results of the RELAP5 system code

    International Nuclear Information System (INIS)

    Trapp, J.A.; Ransom, V.H.

    1983-01-01

    The present RELAP5 code is based on a semi-implicit numerical scheme for the hydrodynamic model. The basic guidelines employed in the development of the semi-implicit numerical scheme are discussed and the numerical features of the scheme are illustrated by analysis for a simple, but analogous, single-equation model. The basic numerical scheme is recorded and results from several simulations are presented. The experimental results and code simulations are used in a complementary fashion to develop insights into nuclear-plant response that would not be obtained if either tool were used alone. Further analysis using the simple single-equation model is carried out to yield insights that are presently being used to implement a more-implicit multi-step scheme in the experimental version of RELAP5. The multi-step implicit scheme is also described

  9. Plans and status of RELAP5/MOD3

    International Nuclear Information System (INIS)

    Weaver, W.L.

    1989-01-01

    RELAP5/MOD3 is a pressurized water reactor (PWR) system analysis code being developed jointly by the US Nuclear Regulatory Commission (USNRC) and consisting of several of the countries that are members of the International Code Assessment and Applications Program (ICAP). This code development program is called the ICAP Code Improvement Program. The mission of the RELAP5/MOD3 code improvement program is to develop a code version suitable for the analysis of all transients and postulated accidents in PER systems including both large and small break loss of coolant accidents (LOCA's) as well as the full range of operational transients. The emphasis of the RELAP5/MOD3 development will be on large break LOCA since previous versions of RELAP5 were developed for and assessed against small break LOCA and operation transient test data. The paper discusses the various code models to be improved and presents the results of work completed to date

  10. The evaluation of validity of the RELAP5/Mod3 flow regime map for horizontal small diameter tubes at low pressure

    Energy Technology Data Exchange (ETDEWEB)

    Agafonova, N. [St. Petersburg State Technical Univ. (Russian Federation); Banati, J. [Lappeenranta Univ. of Technology (Finland)

    1997-12-31

    RELAP5/MOD3 code was developed for Western type power water reactors with vertical steam generators. Thus, this code should be validated also for WWER design with horizontal steam generators. In application for horizontal steam generators the situation with two-phase flow inside small diameter tubes is possible when the first circuit pressure drops in accident below the pressure level in the boiling water. It is known that computer codes have not always modelled correctly the two-phase flow inside horizontal tubes at low pressures (less than 4-6 MPa). It may be the result of erroneous prediction of the flow regime. Correct prediction of the flow regime is especially important for the fully or partly stratified flow in horizontal tubes. The aim of this study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal small diameter tubes. `Small diameter tube` means according RELAP5/MOD3 that the inner diameter of the tube is less (or equal) than 0.018 m. The inner tube diameter in horizontal steam generators is equal 0.013 m. (orig.). 19 refs.

  11. The evaluation of validity of the RELAP5/Mod3 flow regime map for horizontal small diameter tubes at low pressure

    Energy Technology Data Exchange (ETDEWEB)

    Agafonova, N [St. Petersburg State Technical Univ. (Russian Federation); Banati, J [Lappeenranta Univ. of Technology (Finland)

    1998-12-31

    RELAP5/MOD3 code was developed for Western type power water reactors with vertical steam generators. Thus, this code should be validated also for WWER design with horizontal steam generators. In application for horizontal steam generators the situation with two-phase flow inside small diameter tubes is possible when the first circuit pressure drops in accident below the pressure level in the boiling water. It is known that computer codes have not always modelled correctly the two-phase flow inside horizontal tubes at low pressures (less than 4-6 MPa). It may be the result of erroneous prediction of the flow regime. Correct prediction of the flow regime is especially important for the fully or partly stratified flow in horizontal tubes. The aim of this study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal small diameter tubes. `Small diameter tube` means according RELAP5/MOD3 that the inner diameter of the tube is less (or equal) than 0.018 m. The inner tube diameter in horizontal steam generators is equal 0.013 m. (orig.). 19 refs.

  12. Application of RELAP/SCDAPSIM to TRIGA system thermal hydraulic analysis

    International Nuclear Information System (INIS)

    Allison, C.M.; Hohorst, J.K.; Quamrul Huda, Md.

    2010-01-01

    The RELAP/SCDAPSIM/MOD4.0 code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed as part of the international SCDAP Development and Training Program (SDTP). RELAP/SCDAPSIM/MOD4.0, which is the first version of RELAP5 completely rewritten to FORTRAN 90/95/2000 standards, uses publicly available RELAP5 and SCDAP models in combination with advanced programming and numerical techniques and other SDTP-member modeling/user options. This paper describes the development of a representative input model for the 3MW TRIGA research reactor at AERE Bangladesh, describes the testing and qualification of the model using MOD4.0 advanced input checking and graphical display options, and then presents representative results for selected calculations. (author)

  13. The preliminary thermal–hydraulic analysis of a water cooled blanket concept design based on RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guanghuai; Peng, Changhong; Guo, Yun, E-mail: guoyun79@ustc.edu.cn

    2016-11-01

    Highlights: • The superheated steam and PWR schemes are analyzed by RELAP5 code. • The influence of non-uniform heating sources is include. • A supposed slow flow decrease case is discussed and the PWR scheme is better. - Abstract: Water cooled blanket (WCB) is very important in the conceptual design and energy transfer in future fusion power plant. One conceptual design of WCB is under computational testing. RELAP5 code, which is mature and often used in transient analysis in Pressurizer water reactor (PWR), is selected as the simulation tool. The complex inner flow channels and heat sources are simplified according to its thermal–hydraulic characteristics. Then the nodal model for REALP5 is built for approximating the conceptual design. Two typical operating plans, superheated steam scheme and PWR scheme, are analyzed. After some adjustments of the inlet flow resistance coefficients of some flow channels, the reasonable stable conditions of both operation plans can be obtained. The stable fluid and wall temperature distributions and pressure drops are studied. At last, a supposed slow flow decreasing is discussed under two operating conditions separately. According to present results, the superheated steam scheme still needs to be further optimized. The PWR scheme shows a very good safety feature.

  14. The preliminary thermal–hydraulic analysis of a water cooled blanket concept design based on RELAP5 code

    International Nuclear Information System (INIS)

    Wang, Guanghuai; Peng, Changhong; Guo, Yun

    2016-01-01

    Highlights: • The superheated steam and PWR schemes are analyzed by RELAP5 code. • The influence of non-uniform heating sources is include. • A supposed slow flow decrease case is discussed and the PWR scheme is better. - Abstract: Water cooled blanket (WCB) is very important in the conceptual design and energy transfer in future fusion power plant. One conceptual design of WCB is under computational testing. RELAP5 code, which is mature and often used in transient analysis in Pressurizer water reactor (PWR), is selected as the simulation tool. The complex inner flow channels and heat sources are simplified according to its thermal–hydraulic characteristics. Then the nodal model for REALP5 is built for approximating the conceptual design. Two typical operating plans, superheated steam scheme and PWR scheme, are analyzed. After some adjustments of the inlet flow resistance coefficients of some flow channels, the reasonable stable conditions of both operation plans can be obtained. The stable fluid and wall temperature distributions and pressure drops are studied. At last, a supposed slow flow decreasing is discussed under two operating conditions separately. According to present results, the superheated steam scheme still needs to be further optimized. The PWR scheme shows a very good safety feature.

  15. RELAP5/MOD2 code assessment using a LOFT L2-3 loss of coolant experiment

    International Nuclear Information System (INIS)

    Bang, Young Seok; Chung, Bub Dong; Kim, Hho Jung

    1990-01-01

    The LOFT LOCE L2-3 was simulated using the RELAP5/MOD2 Cycle 36.04 code to assess its capability in predicting the thermal-hydraulic phenomena in LBLOCA of the PWR. The reactor vessel was simulated with two core channels and split downcomer modeling for a base case calculation using the frozen code. The result of the base calculation showed that the code predicted the hydraulic behavior, and the blowdown thermal response at high power region of the core in a reasonable range and that the code had deficiencies in the critical flow model during subcooled-two-phase transition period, in the CHF correlation at high mass flux and in the blowdown rewet criteria. An overprediction of coolant inventory due to the deficiencies yielded the poor prediction of reflood thermal response. A Sensitivity calculation with an updated version from RELAP5/MOD2 Cycle 36.04 improved the prediction of the rewet phenomena

  16. Analysis of OECD/CSNI ISP-42 phase A PANDA experiment using coupled code R5G (RELAP5-GOTHIC)

    International Nuclear Information System (INIS)

    Bencik, V.; Debrecin, N.; Grgic, D.; Bajs, T.

    2010-01-01

    In the paper, the results of the analysis of OECD/CSNI ISP-42 Phase A experiment at PANDA facility using stand-alone codes RELAP5/mod3.3 and GOTHIC 7.2b as well as coupled code R5G (RELAP5/mod3.3-GOTHIC 7.2b) are presented. PANDA is a large-scale thermal-hydraulic test facility installed at PSI (Paul Scherrer Institute) in Switzerland. The OECD/CSNI ISP-42 test consists of six sequential phases (Phase A through F). The present work deals with the post-test calculation of the Phase A, including the break of the main steam line and the Passive Containment Cooling (PCC) System Start-Up. The objective of the test is to investigate the start-up phenomenology of passive cooling system when steam is injected into cold vessel filled with air. The calculation was performed using stand-alone RELAP5/mod3.3 and GOTHIC 7.2b models, and then the same calculation was performed using coupled code with RELAP5 being responsible for reactor part of the model and GOTHIC being responsible for containment part of the model. The prediction capability, running time and modeling aspects were discussed for all three cases. (authors)

  17. A study of the dispersed flow interfacial heat transfer model of RELAP5/MOD2.5 and RELAP5/MOD3

    Energy Technology Data Exchange (ETDEWEB)

    Andreani, M. [Swiss Federal Institute of Technology, Zurich (Switzerland); Analytis, G.T.; Aksan, S.N. [Paul Scherrer Institute, Villigen (Switzerland)

    1995-09-01

    The model of interfacial heat transfer for the dispersed flow regime used in the RELAP5 computer codes is investigated in the present paper. Short-transient calculations of two low flooding rate tube reflooding experiments have been performed, where the hydraulic conditions and the heat input to the vapour in the post-dryout region were controlled for the predetermined position of the quench front. Both RELAP5/MOD2.5 and RELAP5/MOD3 substantially underpredicted the exit vapour temperature. The mass flow rate and quality, however, were correct and the heat input to the vapour was larger than the actual one. As the vapour superheat at the tube exit depends on the balance between the heat input from the wall and the heat exchange with the droplets, the discrepancy between the calculated and the measured exit vapour temperature suggested that the inability of both codes to predict the vapour superheat in the dispersed flow region is due to the overprediction of the interfacial heat transfer rate.

  18. Development of a system for a linked analysis of RELAP5 and MAAP4 and its application for an analysis of LB-LOCA case of APR1400

    International Nuclear Information System (INIS)

    Park, Chang Hwan; Lee, Un Chul; Park, Goon Cherl; Suh, Kune Yull

    2004-01-01

    The RELAP5 (1995) and MAAP4 (1994) linked-analysis system was designed and illustrative calculation was performed. A large-break loss-of-coolant accident (LBLOCA) was taken as the reference case for the APR1400 (Advanced Power Reactor 1400MWe). For the early phase of this case, the calculational results of two codes have some deviations in water level depletion and hot assembly temperature. Ordinarily, it is considered that RELAP5 has enough accuracy in calculation of the thermal hydraulic behavior of typical PWR during design basis accidents. If the data set for the thermal hydraulic state of RELAP5 can be well-transferred to MAAP4 as an initial condition, the overall transients given by the linked analysis can get more reliability. In this study, the linked analysis system of RELAP5 and MAAP4 doesn't mean the mechanically integrated code structure. The objective of this study is to formulate the linked analysis system of RELAP5 and MAAP4, which should precede construction of mechanically integrated analyzer. Thus, the main scope of this work covers development of the methodology for data linkage and decision of the transfer timing

  19. RBMK fuel channel blockage analysis by MCNP5, DRAGON and RELAP5-3D codes

    International Nuclear Information System (INIS)

    Parisi, C.; D'Auria, F.

    2007-01-01

    The aim of this work was to perform precise criticality analyses by Monte-Carlo code MCNP5 for a Fuel Channel (FC) flow blockage accident, considering as calculation domain a single FC and a 3x3 lattice of RBMK cells. Boundary conditions for MCNP5 input were derived by a previous transient calculation by state-of-the-art codes HELIOS/RELAP5-3D. In a preliminary phase, suitable MCNP5 models of a single cell and of a small lattice of RBMK cells were set-up; criticality analyses were performed at reference conditions for 2.0% and 2.4% enriched fuel. These analyses were compared with results obtained by University of Pisa (UNIPI) using deterministic transport code DRAGON and with results obtained by NIKIET Institute using MCNP4C. Then, the changes of the main physical parameters (e.g. fuel and water/steam temperature, water density, graphite temperature) at different time intervals of the FC blockage transient were evaluated by a RELAP5-3D calculation. This information was used to set up further MCNP5 inputs. Criticality analyses were performed for different systems (single channel and lattice) at those transient' states, obtaining global criticality versus transient time. Finally the weight of each parameter's change (fuel overheating and channel voiding) on global criticality was assessed. The results showed that reactivity of a blocked FC is always negative; nevertheless, when considering the effect of neighboring channels, the global reactivity trend reverts, becoming slightly positive or not changing at all, depending in inverse relation to the fuel enrichment. (author)

  20. RELAP-7 and PRONGHORN Initial Integration Plan

    Energy Technology Data Exchange (ETDEWEB)

    J. Ortensi; D. Andrs; A.A. Bingham; R.C. Martineau; J.W. Peterson

    2012-05-01

    Modern nuclear reactor safety codes require the ability to solve detailed coupled neutronicthermal fluids problems. For larger cores, this implies fully coupled 3-D spatial dynamics with appropriate feedback models that can provide enough resolution to accurately compute core heat generation and removal during steady and unsteady conditions. The reactor analyis code PRONGHORN is being coupled to RELAP-7 as a first step to extend RELAP's current capabilities. This report details the mathematical models, the type of coupling, and the testing that will be used to produce an integrated system. RELAP-7 is a MOOSE-based application that solves the continuity, momentum, and energy equations in 1-D for a compressible fluid. The pipe and joint capabilities enable it to model parts of the PCU system. The PRONGHORN application, also developed on the MOOSE infrastructure, solves the coupled equations that define the neutron diffusion, fluid flow, and heat transfer in a 3-D core model. Initially, the two systems will be loosely coupled to simplify the transition towards a more complex infrastructure. The integration will be tested with the OECD/NEA MHTGR-350 Coupled Neutronics-Thermal Fluids benchmark model.

  1. Assessment of RELAP5/MOD2 against a natural circulation experiment in Nuclear Power Plant Borssele

    International Nuclear Information System (INIS)

    Winters, L.

    1993-07-01

    As part of the ICAP (International Code Assessment and Applications Program) agreement between ECN (Netherlands Energy Research Foundation) and USNRC, ECN has performed a number of assessment calculations for the thermohydraulic system analysis code RELAP5/MOD2/36.05. This document describes the assessment of this computer program versus a natural circulation experiment as conducted at the Borssele Nuclear Power Plant. The results of this comparison show that the code RELAP5/MOD2 predicts well the natural circulation behaviour of Nuclear Power Plant Borssele

  2. RELAP5-3D Resolution of Known Restart/Backup Issues

    Energy Technology Data Exchange (ETDEWEB)

    Mesina, George L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Anderson, Nolan A. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-12-01

    The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequential verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.

  3. Design, experiments and Relap5 code calculations for the perseo facility

    International Nuclear Information System (INIS)

    Ferri, Roberta; Achilli, Andrea; Cattadori, Gustavo; Bianchi, Fosco; Meloni, Paride

    2005-01-01

    Research on innovative safety systems for light water reactors addressed to heat removal by in-pool immersed heat exchangers, led to design, build-up and test the PERSEO facility at SIET laboratories. The research started with the CEA-ENEA proposal of improving the GE-SBWR isolation condenser system, by moving the triggering valve from the high pressure primary side of the reactor to the low pressure pool side. A new configuration of the system was defined with the heat exchanger contained in a small pool, connected at bottom and top to a large water reservoir pool, the triggering valve being located on the pool bottom connecting pipe. ENEA funded the whole activity that included the definition and build-up of a new heat exchanger pool, on the basis of the already existing PANTHERS IC-PCC facility, at SIET laboratories, and the new plant requirements. The heat exchanger connections to the pressure vessel were maintained. An experimental campaign was executed at full scale and full thermal-hydraulic conditions for investigating the behaviour and performance of the plant in steady and unsteady conditions. The Relap5 code was utilised during all phases of the research: for the heat exchanger pool dimension definition and from pre-test and post-test analyses. The Cathare code was applied too from pre-test and post-test analyses. This paper deals with the experimental and calculated results limited to the Relap5 code

  4. RELAP5-3D User Problems

    International Nuclear Information System (INIS)

    Riemke, Richard Allan

    2001-01-01

    The Reactor Excursion and Leak Analysis Program with 3D capability (RELAP5-3D) is a reactor system analysis code that has been developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the U. S. Department of Energy (DOE). The 3D capability in RELAP5-3D includes 3D hydrodynamics and 3D neutron kinetics. Assessment, verification, and validation of the 3D capability in RELAP5-3D is discussed in the literature. Additional assessment, verification, and validation of the 3D capability of RELAP5-3D will be presented in other papers in this users seminar. As with any software, user problems occur. User problems usually fall into the categories of input processing failure, code execution failure, restart/renodalization failure, unphysical result, and installation. This presentation will discuss some of the more generic user problems that have been reported on RELAP5-3D as well as their resolution

  5. Applicability of coupled code RELAP5/GOTHIC to NPP Krsko MSLB calculation

    International Nuclear Information System (INIS)

    Keco, M.; Debrecin, N.; Grgic, D.

    2005-01-01

    Usual way to analyze Main Steam Line Break (MSLB) accident in PWR plants is to calculate core and containment responses in two separate calculations. In first calculation system code is used to address behaviour of nuclear steam supply system and containment is modelled mainly as a boundary condition. In second calculation mass and energy release data are used to perform containment analysis. Coupled code R5G realized by direct explicit coupling of system code RELAP5/MOD3.3 and containment code GOTHIC is able to perform both calculations simultaneously. In this paper R5G is applied to calculation of MSLB accident in large dry containment of NPP Krsko. Standard separate calculation is performed first and then both core and containment responses are compared against corresponding coupled code results. Two versions of GOTHIC code are used, one old ver 3.4e and the last one ver 7.2. As expected, differences between standard procedure and coupled calculations are small. The performed analyses showed that classical uncoupled approach is applicable in case of large dry containment calculation, but that new approach can bring some additional insight in understanding of the transient and that can be used as simple and reliable procedure in performing MSLB calculation without any significant calculation overhead. (author)

  6. Computer and compiler effects on code results: status report

    International Nuclear Information System (INIS)

    1996-01-01

    Within the framework of the international effort on the assessment of computer codes, which are designed to describe the overall reactor coolant system (RCS) thermalhydraulic response, core damage progression, and fission product release and transport during severe accidents, there has been a continuous debate as to whether the code results are influenced by different code users or by different computers or compilers. The first aspect, the 'Code User Effect', has been investigated already. In this paper the other aspects will be discussed and proposals are given how to make large system codes insensitive to different computers and compilers. Hardware errors and memory problems are not considered in this report. The codes investigated herein are integrated code systems (e. g. ESTER, MELCOR) and thermalhydraulic system codes with extensions for severe accident simulation (e. g. SCDAP/RELAP, ICARE/CATHARE, ATHLET-CD), and codes to simulate fission product transport (e. g. TRAPMELT, SOPHAEROS). Since all of these codes are programmed in Fortran 77, the discussion herein is based on this programming language although some remarks are made about Fortran 90. Some observations about different code results by using different computers are reported and possible reasons for this unexpected behaviour are listed. Then methods are discussed how to avoid portability problems

  7. Uncertainty and sensitivity analysis in the scenario simulation with RELAP/SCDAP and MELCOR codes; Analisis de incertidumbre y sensibilidad en la simulacion de escenarios con los codigos RELAP/SCDAP y MELCOR

    Energy Technology Data Exchange (ETDEWEB)

    Garcia J, T.; Cardenas V, J., E-mail: tonatiuh.garcia@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    A methodology was implemented for analysis of uncertainty in simulations of scenarios with RELAP/SCDAP V- 3.4 bi-7 and MELCOR V-2.1 codes, same that are used to perform safety analysis in the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). The uncertainty analysis methodology chosen is a probabilistic method of type Propagation of uncertainty of the input parameters to the departure parameters. Therefore, it began with the selection of the input parameters considered uncertain and are considered of high importance in the scenario for its direct effect on the output interest variable. These parameters were randomly sampled according to intervals of variation or probability distribution functions assigned by expert judgment to generate a set of input files that were run through the simulation code to propagate the uncertainty to the output parameters. Then, through the use or ordered statistical and formula Wilks, was determined that the minimum number of executions required to obtain the uncertainty bands that include a population of 95% at a confidence level of 95% in the results is 93, is important to mention that in this method that number of executions does not depend on the number of selected input parameters. In the implementation routines in Fortran 90 that allowed automate the process to make the uncertainty analysis in transients for RELAP/SCDAP code were generated. In the case of MELCOR code for severe accident analysis, automation was carried out through complement Dakota Uncertainty incorporated into the Snap platform. To test the practical application of this methodology, two analyzes were performed: the first with the simulation of closing transient of the main steam isolation valves using the RELAP/SCDAP code obtaining the uncertainty band of the dome pressure of the vessel; while in the second analysis, the accident simulation of the power total loss (Sbo) was carried out with the Macarol code obtaining the uncertainty band for the

  8. PACTEL ISP-33. RELAP5 assessment

    International Nuclear Information System (INIS)

    Siccama, N.B.; Roodbergen, H.A.

    1995-08-01

    This report presents the results of the calculation of the PACTEL ISP-33 experiment as obtained from the RELAP5 code. The main goal of the ECN contribution to this ISP was to assess RELAP5 on one- and two-phase natural circulation phenomena which occur in Eastern European VVER plants in case of LOCA conditions. Different natural circulation modes were calculated in the simulation of the ISP-33 experiment. The single-phase liquid flow, the steady two-phase flow, and the boiler-condenser single-phase heat removal are calculated well by the RELAP5 code. The phenomena in the transient two-phase flow are difficult to simulate. (orig.)

  9. Detailed computational fluid dynamics calculations in order to assess respective safety issues regarding existing nuclear power plant. Detailed study of three-dimensional flow characteristics formed in the reactor internal components in order to improve RELAP5 system TH code model

    International Nuclear Information System (INIS)

    2015-06-01

    In RELAP5 model, resistance coefficients calculated based on ANSYS CFX results were implemented. Comparison of calculation results of ANSYS CFX and RELAP5 was performed. Results of analysis showed that general behavior of pressure for both codes is similar. The reason for some differences is the more precise calculation of resistance and corresponding turbulent flow effects in ANSYS, while in RELAP5 turbulent friction factor is given by the empirical correlation which overestimates the resistance due to turbulence. The behavior of temperature is similar in both codes. The difference of 0.25 degrees exists, which is conditioned by coarse nodalization of RELAP5

  10. Model of nuclear reactor type VVER-1000/V-320 built by computer code ATHLET-CD

    International Nuclear Information System (INIS)

    Georgiev, Yoto; Filipov, Kalin; Velev, Vladimir

    2014-01-01

    A model of nuclear reactor type VVER-1000 V-320 developed for computer code ATHLET-CD2.1A is presented. Validation of the has been made, in the analysis of the station blackout scenario with LOCA on fourth cold leg is shown. As the calculation has been completed, the results are checked through comparison with the results from the computer codes ATHLET-2.1A, ASTEC-2.1 and RELAP5mod3.2

  11. Development of the bubble rise model in RELAP-UK

    International Nuclear Information System (INIS)

    Holmes, J.A.

    1977-11-01

    Several improvements have been made to the 'bubble rise calculation' in the code RELAP-UK, which models the separation of the steam and water phases within specified volumes of the coolant circuit. The bubble rise velocity and the bubble density gradient parameter are no longer necessarily user-defined constants, as the code can calculate their values at each time step according to the local fluid conditions. In particular, the calculation of the bubble rise velocity is consistent with the RELAP-UK drift flux correlation. It is now possible to represent a vertical column by a stack of vertically-adjacent bubble-rise volumes. Any mixture level existing within the column can freely pass between the volumes in the stack. The facilities are demonstrated in this paper by a simple computational example. (author)

  12. Independent assessment of TRAC and RELAP5 codes through separate effects tests

    International Nuclear Information System (INIS)

    Saha, P.; Rohatgi, U.S.; Jo, J.H.; Neymotin, L.; Slovik, G.; Yuelys-Miksis, C.; Pu, J.

    1983-01-01

    Independent assessment of TRAC-PF1 (Version 7.0), TRAC-BD1 (Version 12.0) and RELAP5/MOD1 (Cycle 14) that was initiated at BNL in FY 1982, has been completed in FY 1983. As in the previous years, emphasis at Brookhaven has been in simulating various separate-effects tests with these advanced codes and identifying the areas where further thermal-hydraulic modeling improvements are needed. The following six catetories of tests were simulated with the above codes: (1) critical flow tests (Moby-Dick nitrogen-water, BNL flashing flow, Marviken Test 24); (2) Counter-Current Flow Limiting (CCFL) tests (University of Houston, Dartmouth College single and parallel tube test); (3) level swell tests (G.E. large vessel test); (4) steam generator tests (B and W 19-tube model S.G. tests, FLECHT-SEASET U-tube S.G. tests); (5) natural circulation tests (FRIGG loop tests); and (6) post-CHF tests (Oak Ridge steady-state test)

  13. FRAPCON-2: A Computer Code for the Calculation of Steady State Thermal-Mechanical Behavior of Oxide Fuel Rods

    Energy Technology Data Exchange (ETDEWEB)

    Berna, G. A; Bohn, M. P.; Rausch, W. N.; Williford, R. E.; Lanning, D. D.

    1981-01-01

    FRAPCON-2 is a FORTRAN IV computer code that calculates the steady state response of light Mater reactor fuel rods during long-term burnup. The code calculates the temperature, pressure, deformation, and tai lure histories of a fuel rod as functions of time-dependent fuel rod power and coolant boundary conditions. The phenomena modeled by the code include (a) heat conduction through the fuel and cladding, (b) cladding elastic and plastic deformation, (c) fuel-cladding mechanical interaction, (d) fission gas release, (e} fuel rod internal gas pressure, (f) heat transfer between fuel and cladding, (g) cladding oxidation, and (h) heat transfer from cladding to coolant. The code contains necessary material properties, water properties, and heat transfer correlations. FRAPCON-2 is programmed for use on the CDC Cyber 175 and 176 computers. The FRAPCON-2 code Is designed to generate initial conditions for transient fuel rod analysis by either the FRAP-T6 computer code or the thermal-hydraulic code, RELAP4/MOD7 Version 2.

  14. A PWR hot-rod model: Relap5/mod3.2.2.{gamma} as a subchannel code

    Energy Technology Data Exchange (ETDEWEB)

    Kirsten, I.C.; Jones, J.R. [British Energy, Barnwood, Gloucester (United Kingdom); Kimber, G.R. [Atomic Energy Authority Technology, Winfrith, Dorset (United Kingdom); Page, R. [National Nuclear Corp. Ltd., Cheshire (United Kingdom)

    2001-07-01

    The use of the PWR transient analysis code RELAP5 for detailed assessment of Departure from Nucleate Boiling (DNB) has previously implied coupling it in some way to a subchannel code, either by direct code-to-code coupling or by transferring core boundary conditions to the subchannel code. This paper shows an alternative by using a group of subchannels modelled in RELAP5 to represent a hot rod. The model consists of three parallel channels, each more refined than its neighbour: The first channel represents a quadrant of the core; the second a quadrant on a fuel assembly and the final channel represents a passage adjacent to a single fuel pin. The model is intended for use as part of point kinetics assessments and each channel is assigned a radial form factor designed to conservatively represent the hottest fuel pins in the reactor core. The main outputs from the model are minimum Departure from Nucleate Boiling Ratio (DNBR) and clad oxidation for the hot rod (lead pin). The DNBR results from the hot-rod model are benchmarked against the subchannel code COBRA 3-CP and the results are presented in this paper. Some of the modelling problems that needed to be resolved are also highlighted. (author)

  15. RELAP5/MOD3 code manual: User's guide and input requirements. Volume 2

    International Nuclear Information System (INIS)

    1995-08-01

    The RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents, and operational transients, such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. Volume II contains detailed instructions for code application and input data preparation

  16. Assessment of critical flow models of RELAP5-MOD2 and CATHARE codes

    International Nuclear Information System (INIS)

    Hao Laomi; Zhu Zhanchuan

    1992-01-01

    The critical flow tests for the long and short nozzles conducted on the SUPER MOBY-DICK facility were analyzed using the RELAP5-MOD2 and CATHARE 1.3 codes to assess the critical flow models of two codes. The critical mass flux calculated for two nozzles are given. The CATHARE code has used the thermodynamic nonequilibrium sound velocity of the two-phase fluid as the critical flow criterion, and has the better interphase transfer models and calculates the critical flow velocities with the completely implicit solution. Therefore, it can well calculate the critical flowrate and can describe the effect of the geometry L/D on the critical flowrate

  17. RELAP5 modification for CHEOPE simulations

    International Nuclear Information System (INIS)

    Casamirra, M.; Castiglia, F.; Giardina, M.; Meloni, P.

    2005-01-01

    Nowadays, an extensive R and D program is in progress in order to maximize the safety of the Lead-Bismuth Eutectic alloy (LBE) ADS plants and optimise their layout. Recently, in the framework of the collaboration between the Department of Nuclear Engineering of the University of Palermo and the ENEA ''E. Clementel'' Research Centre in Bologna, validation works on the LBE RELAP5mod3.2.2a code, were carried out. The validation was based on the experimental tests performed on the CHEOPE (CHEmical OPErational transient) facility, an experimental rig built up to evaluate the heat transfer performances between the LBE and a diathermic oil secondary fluid, in support to the MEGAPIE (MEGAwatt PIlot Experiment) project, aimed at testing the LBE spallation target technology at 1 MW proton-beam power. As expected, the comparison between the experimental results and post test calculations highlighted not fully satisfactory RELAP5 evaluations of the oil-side heat transfer coefficient, due to RELAP5 code inadequacies in predicting the 3D effects induced in the oil bulk by the facility peculiar geometry, about which is referred in the following. In the present paper we have suitably modified the RELAP5 heat transfer model, to take into account the consequent improved heat transfer conditions. The obtained results show very good performance of the so modified RELAP5 code. (author)

  18. Modelling and thermal hydraulic analysis of the Angra-2 nuclear reactor using RELAP5-3D code

    International Nuclear Information System (INIS)

    González Mantecón, Javier

    2015-01-01

    The evaluation of Nuclear Power Plants (NPPs) performance during steady-state and accident conditions has been one of the main research subjects in the nuclear field. In order to simulate the behavior of water-cooled reactors, several complex thermal-hydraulic codes systems have been developed. Particularly, the RELAP5 code, developed by the Idaho National Laboratory, is a best-estimate thermal-hydraulic analysis tool and one of the most used in nuclear industry. The RELAP5-3D 3.0.0 code was used to develop a detailed model of Angra 2 nuclear reactor using reference data from the Final Safety Analysis Report. Angra 2 is the second Brazilian NPP, which began commercial operation in 2001. The plant is equipped with a Pressurized Water Reactor (PWR) type with 3771.0 MWt. Simulations of the reactor behavior during normal operation conditions and postulated accident conditions were performed. Results achieved in the reactor steady-state simulation were compared with nominal parameters of the NPP. These results proved to be in good agreement, with relative errors less than 1%. In the transient simulation, the obtained results were coherent and satisfactory. This study demonstrates that the RELAP5-3D model is capable to reproduce the thermal-hydraulic behavior of the Angra-2 PWR during diverse operation conditions and it can contribute for the process of the plant safety analysis. (author)

  19. RELAP5/MOD3.3 assessment against MSIV closure events in Krsko NPP

    International Nuclear Information System (INIS)

    Parzer, I.

    2002-01-01

    The paper presents RELAP5/MOD3.3 analysis of two abnormal events occurred in Krsko NPP originating from sudden closure of Main Steam Isolation Valve (MSIV). Both events occurred before the SG replacement in 2000, the first one in September 1995 and the second one in January 1997. Valuable plant data were obtained from real plant transients and the RELAP5 code assessment was performed. Recently the last frozen version RELAP5/MOD3.3 has been released, before merging with another best-estimate thermalhydraulic system code TRAC into an integrated code. It is thus of utmost importance to assess models built in RELAP5 code against real plant transients before the code merger. A full twoloop plant model, developed at Jozef Stefan Institute (JSI), has been used for the analyses. The model includes old Westinghouse D4 type steam generators (SGs) with assumed 18% Utubes plugged in both steam generators. In the first case a malfunction in the MSIV in SG-1 caused inadvertent valve closure, while in the second case the valve stem has been broken in the SG-2, which also caused sudden valve closure.(author)

  20. Study of the Relap5/mod3.2 wall heat flux partitioning model

    International Nuclear Information System (INIS)

    Hari, S.; Hassan, Y.A.

    2001-01-01

    The performance of the subcooled boiling model adapted in RELAP5/MOD3.2 computer code has been assessed in detail for low-pressure conditions and it has been found that the void fraction profile is under-predicted. In general, any subcooled boiling model is composed of individual sub-models that account for the different physical mechanism that govern the overall process, as the wall vapor generation, interfacial shear and condensation etc. The wall heat flux partitioning model is one of the important sub-models that is a constituent of any subcooled boiling model. The function of this model is to apportion the wall heat flux to the different components (as the single/two phase fluid or bubble), as the case may be, in a two-phase flow-boiling scenario adjacent to a heated wall. The ''pumping factor'' approach is generally followed by most of the wall heat flux partitioning models, for partitioning the wall heat flux. In this work, the wall heat flux partitioning model of RELAP5/MOD3.2 computer code is studied; in particular, the ''pumping factor'' formulation in the present code version is assessed for its performance under low-pressure conditions. In addition, three different ''pumping factor'' formulations available in the literature have been introduced into the RELAP5/MOD3.2 code. Simulations of two low-pressure subcooled flow boiling experiments were performed with the refined code versions to determine the appropriate pumping factor to be used under these conditions. (author)

  1. Implementation of a nonequilibrium condensation model in RELAP4/MOD7

    International Nuclear Information System (INIS)

    Fischer, S.R.; Chow, H.; Van Arsdall, G.

    1979-01-01

    RALAp, which is used to simulate the thermal hydraulic behavior of light water reactors subjected to various LOCA transients, is based on the assumption of thermodynamic equilibrium between liquid and vapor within fluid volumes. This assumption, while being appropriate for much of a LOCA transient, is not adequate during the ECC accumulator injection phase as determined by comparisons of code calculations with experimental data. To overcome this limitation, a general model to simulate the nonequilibrium phenomena associated with the mixing of subcooled water with saturated steam has been developed and is operational on preliminary versions of RELAP4/MOD7

  2. Assessment of the RELAP5 multi-dimensional component model using data from LOFT test L2-5

    International Nuclear Information System (INIS)

    Davis, C.B.

    1998-01-01

    The capability of the RELAP5-3D computer code to perform multi-dimensional analysis of a pressurized water reactor (PWR) was assessed using data from the LOFT L2-5 experiment. The LOFT facility was a 50 MW PWR that was designed to simulate the response of a commercial PWR during a loss-of-coolant accident. Test L2-5 simulated a 200% double-ended cold leg break with an immediate primary coolant pump trip. A three-dimensional model of the LOFT reactor vessel was developed. Calculations of the LOFT L2-5 experiment were performed using the RELAP5-3D Version BF02 computer code. The calculated thermal-hydraulic responses of the LOFT primary and secondary coolant systems were generally in reasonable agreement with the test. The calculated results were also generally as good as or better than those obtained previously with RELAP/MOD3

  3. A three-dimensional nodal neutron kinetics capability for relaps

    International Nuclear Information System (INIS)

    Judd, J.L.; Weaver, W.L.

    1996-01-01

    The incorporation of a three-dimensional neutron kinetics capability into the DOE version of the RELAP5/MOD3.2 reactor safety code is discussed. A brief discussion of the kinetics method is given along with a discussion of the cross section parameterization models available in RELAP5/MOD3.2. The RELAP5/MOD3.2 code is then used to perform calculations of the NEACRP rod ejection and rod withdrawal benchmarks, and results are presented

  4. Peer review of RELAP5/MOD3 documentation

    International Nuclear Information System (INIS)

    Craddick, W.G.

    1994-01-01

    A peer review was performed on a portion of the documentation of the RELAP5/MOD3 computer code. The review was performed in two phases. The first phase was a review of Vol. III, Developmental Assessment Problems, and Vol. IV, Models and Correlations. The reviewers for this phase were Dr. Peter Griffith, Dr. Yassin Hassan, Dr. Gerald S. Lellouche, Dr. Marino di Marzo and Mr. Mark Wendel. The reviewers recommended a number of improvements, including using a frozen version of the code for assessment guided by a validation plan, better discussion of discrepancies between the code and experimental data, and better justification for flow regime maps and extension of models beyond their data base. The second phase was a review of Vol. VI, Quality Assurance of Numerical Techniques in RELAP5/MOD3. The reviewers for the second phase were Mr. Mark Wendel and Dr. Paul T. Williams. Recommendations included correction of numerous grammatical and typographical errors and better justification for the use of Lax's Equivalence Theorem

  5. Analysis of the main steam line break accident with loss of offsite power using the fully coupled RELAP5/PANTHER/COBRA code package

    International Nuclear Information System (INIS)

    Ruben Van Parys; Sandrine Bosso; Christophe Schneidesch; Jinzhao Zhang

    2005-01-01

    Full text of publication follows: A coupled thermal hydraulics-neutronics code package (RELAP5/PANTHER/COBRA) has been qualified for accident analysis at Tractebel Engineering. In the TE coupled code package, the best estimate thermal-hydraulic system code, RELAP5/MOD2.5, is coupled with the full three-dimensional reactor core kinetics code, PANTHER, via a dynamic data exchange control and processing tool, TALINK. An interface between PANTHER code and the sub-channel thermal-hydraulic analysis code COBRA-IIIC is developed in order to perform online calculation of Departure from Nucleate Boiling Ratio (DNBR). The TE coupled code package has been applied to develop a MSLB accident analysis methodology using the TE deterministic bounding approach. The methodology has been applied for MSLB accident analysis in support of licensing of the power up-rate and steam generator replacement of the Doel 2 plant. The results of coupled thermal-hydraulic and neutronic analysis of SLB show that there exists an important margin in the traditional FSAR MSLB accident analysis. As a specific licensing requirement, the main steam line break accident with loss of offsite power has to be analyzed. In the standard methodology with the coupled RELAP5/PANTHER code, and some corrective methods has to be taken in order to overcome the limitations due to the close-channel T/H model in PANTHER at low flow conditions. The results show that the steam line break accident with loss of offsite power is far less limiting. In order to verify the effect of the cross-flow at low flow conditions, the fully dynamic coupling of RELAP5/PANTHER/COBRA code package is used for reanalysis of this case, in which the PANTHER close-channel T/H model is replaced by the COBRA sub-channel T/H model with crossflow option. It has been demonstrated that, although the consideration of cross-flow in this challenging situation may lead to higher core return to power and slightly lower DNBR than in the standard methodology

  6. Analysis of the main steam line break accident with loss of offsite power using the fully coupled RELAP5/PANTHER/COBRA code package

    Energy Technology Data Exchange (ETDEWEB)

    Ruben Van Parys; Sandrine Bosso; Christophe Schneidesch; Jinzhao Zhang [Nuclear Department, Suez-Tractebel Engineering, avenue Ariane 5, B-1200 Brussels (Belgium)

    2005-07-01

    Full text of publication follows: A coupled thermal hydraulics-neutronics code package (RELAP5/PANTHER/COBRA) has been qualified for accident analysis at Tractebel Engineering. In the TE coupled code package, the best estimate thermal-hydraulic system code, RELAP5/MOD2.5, is coupled with the full three-dimensional reactor core kinetics code, PANTHER, via a dynamic data exchange control and processing tool, TALINK. An interface between PANTHER code and the sub-channel thermal-hydraulic analysis code COBRA-IIIC is developed in order to perform online calculation of Departure from Nucleate Boiling Ratio (DNBR). The TE coupled code package has been applied to develop a MSLB accident analysis methodology using the TE deterministic bounding approach. The methodology has been applied for MSLB accident analysis in support of licensing of the power up-rate and steam generator replacement of the Doel 2 plant. The results of coupled thermal-hydraulic and neutronic analysis of SLB show that there exists an important margin in the traditional FSAR MSLB accident analysis. As a specific licensing requirement, the main steam line break accident with loss of offsite power has to be analyzed. In the standard methodology with the coupled RELAP5/PANTHER code, and some corrective methods has to be taken in order to overcome the limitations due to the close-channel T/H model in PANTHER at low flow conditions. The results show that the steam line break accident with loss of offsite power is far less limiting. In order to verify the effect of the cross-flow at low flow conditions, the fully dynamic coupling of RELAP5/PANTHER/COBRA code package is used for reanalysis of this case, in which the PANTHER close-channel T/H model is replaced by the COBRA sub-channel T/H model with crossflow option. It has been demonstrated that, although the consideration of cross-flow in this challenging situation may lead to higher core return to power and slightly lower DNBR than in the standard methodology

  7. Validation of thermal hydraulic computer codes for advanced light water reactor

    International Nuclear Information System (INIS)

    Macek, J.

    2001-01-01

    The Czech Republic operates 4 WWER-440 units, two WWER-1000 units are being finalised (one of them is undergoing commissioning). Thermal-hydraulics Department of the Nuclear Research Institute Rez performs accident analyses for these plants using a number of computer codes. To model the primary and secondary circuits behaviour the system codes ATHLET, CATHARE, RELAP, TRAC are applied. Containment and pressure-suppressure system are modelled with RALOC and MELCOR codes, the reactor power calculations (point and space-neutron kinetics) are made with DYN3D, NESTLE and CDF codes (FLUENT, TRIO) are used for some specific problems. An integral part of the current Czech project 'New Energy Sources' is selection of a new nuclear source. Within this and the preceding projects financed by the Czech Ministry of Industry and Trade and the EU PHARE, the Department carries and has carried out the systematic validation of thermal-hydraulic and reactor physics computer codes applying data obtained on several experimental facilities as well as the real operational data. The paper provides a concise information on these activities of the NRI and its Thermal-hydraulics Department. A detailed example of the system code validation and the consequent utilisation of the results for a real NPP purposes is included. (author)

  8. Evaluation of the applicability of cladding deformation model in RELAP5/MOD3.2 code for VVER-1000 fuel

    International Nuclear Information System (INIS)

    Vorob'ev, Yu.; Zhabin, O.

    2015-01-01

    Applicability of cladding deformation model in RELAP5/MOD3.2 code is analyzed for VVER-1000 fuel cladding from Zr+1%Nb alloy. Experimental data and calculation model of fuel assembly channel of the core are used for this purpose. The model applicability is tested for the cladding temperature range from 600 to 1200 deg C and pressure range from 1 to 12 MPa. Evaluation results demonstrate limited applicability of built-in RELAP5/MOD3.2 cladding deformation model to the estimation of Zr+1%Nb cladding rupture conditions. The limitations found shall be considered in application of RELAP5/MOD3.2 cladding deformation model in the design-basis accident analysis of VVER reactors

  9. Pump-stopping water hammer simulation based on RELAP5

    International Nuclear Information System (INIS)

    Yi, W S; Jiang, J; Li, D D; Lan, G; Zhao, Z

    2013-01-01

    RELAP5 was originally designed to analyze complex thermal-hydraulic interactions that occur during either postulated large or small loss-of-coolant accidents in PWRs. However, as development continued, the code was expanded to include many of the transient scenarios that might occur in thermal-hydraulic systems. The fast deceleration of the liquid results in high pressure surges, thus the kinetic energy is transformed into the potential energy, which leads to the temporary pressure increase. This phenomenon is called water hammer. Generally water hammer can occur in any thermal-hydraulic systems and it is extremely dangerous for the system when the pressure surges become considerably high. If this happens and when the pressure exceeds the critical pressure that the pipe or the fittings along the pipeline can burden, it will result in the failure of the whole pipeline integrity. The purpose of this article is to introduce the RELAP5 to the simulation and analysis of water hammer situations. Based on the knowledge of the RELAP5 code manuals and some relative documents, the authors utilize RELAP5 to set up an example of water-supply system via an impeller pump to simulate the phenomena of the pump-stopping water hammer. By the simulation of the sample case and the subsequent analysis of the results that the code has provided, we can have a better understand of the knowledge of water hammer as well as the quality of the RELAP5 code when it's used in the water-hammer fields. In the meantime, By comparing the results of the RELAP5 based model with that of other fluid-transient analysis software say, PIPENET. The authors make some conclusions about the peculiarity of RELAP5 when transplanted into water-hammer research and offer several modelling tips when use the code to simulate a water-hammer related case

  10. Pump-stopping water hammer simulation based on RELAP5

    Science.gov (United States)

    Yi, W. S.; Jiang, J.; Li, D. D.; Lan, G.; Zhao, Z.

    2013-12-01

    RELAP5 was originally designed to analyze complex thermal-hydraulic interactions that occur during either postulated large or small loss-of-coolant accidents in PWRs. However, as development continued, the code was expanded to include many of the transient scenarios that might occur in thermal-hydraulic systems. The fast deceleration of the liquid results in high pressure surges, thus the kinetic energy is transformed into the potential energy, which leads to the temporary pressure increase. This phenomenon is called water hammer. Generally water hammer can occur in any thermal-hydraulic systems and it is extremely dangerous for the system when the pressure surges become considerably high. If this happens and when the pressure exceeds the critical pressure that the pipe or the fittings along the pipeline can burden, it will result in the failure of the whole pipeline integrity. The purpose of this article is to introduce the RELAP5 to the simulation and analysis of water hammer situations. Based on the knowledge of the RELAP5 code manuals and some relative documents, the authors utilize RELAP5 to set up an example of water-supply system via an impeller pump to simulate the phenomena of the pump-stopping water hammer. By the simulation of the sample case and the subsequent analysis of the results that the code has provided, we can have a better understand of the knowledge of water hammer as well as the quality of the RELAP5 code when it's used in the water-hammer fields. In the meantime, By comparing the results of the RELAP5 based model with that of other fluid-transient analysis software say, PIPENET. The authors make some conclusions about the peculiarity of RELAP5 when transplanted into water-hammer research and offer several modelling tips when use the code to simulate a water-hammer related case.

  11. Analysis of reactivity transient for the DIDO type research reactors using RELAP5

    International Nuclear Information System (INIS)

    Adorni, M.; Bousbia-Salah, A.; D'Auria, F.; Nabbi, R.

    2005-01-01

    Recent availability of high performance computers and computational methods together with the continuing increase in operational experience imposes revising some operational constrains and conservative safety margins. The application of Best-Estimate (BE) method constitutes a real necessity in the safety and design analysis and allows getting more realistic simulation of the processes taking place during the steady state operation and transients. In comparison to the conservative approaches, the application of Best-Estimate methods results in the mitigation of the constraining limits in design and operation. This paper presents the results of the application of the RELAP5/Mod3.3 system thermal-hydraulic code to the German FRJ-2 research reactor for a reactivity transient, which has been analyzed in the past using the verified system code CATHENA [1], [2], [3]. The work mainly aims checking the capability of RELAP5 [4] for research reactor transient analysis by the comparison of the results of the two codes and including modeling basis and analytical approaches. According to the existing references RELAP5 applications are concentrated on the transient analysis of nuclear power systems. The considered case consists of a simulation related to a hypothetical fast reactivity transient, which is assumed to be caused by the failure of one shutdown arm. The case has been chosen due to the importance of the models for the precise description of the complex phenomenon of subcooled boiling and two phase flow taking place during the transient. For this purpose, the fuel element assembly was modeled in detail according to design data. The primary circuit was included in the whole model in order to consider the interaction with individual fuel elements with core. In general the results of the two codes are in agreement and comparable during the initial phase of the transient. After reaching the flow regime with fully developed nucleate boiling and two phase flow RELAP5 exhibits

  12. RELAP5/MOD3 AP600 problems

    International Nuclear Information System (INIS)

    Riemke, R.A.

    1993-01-01

    RELAP5/MOD3 is a reactor systems analysis code that has been developed jointly by the US Nuclear Regulatory Commission (USNRC) and a consortium consisting of several of the countries and domestic organizations that were members of the International Code Assessment and Applications Program (ICAP). The code is currently being used to simulate transients for the next generation of advanced light water reactors (ALWR's). One particular reactor design is the Westinghouse AP600 pressurized water reactor (PWR), which consists of two hot legs and four cold legs as well as passive emergency core cooling (ECC) systems. Initial calculations with RELAP5/MOD3 indicated that the code was not as robust as RELAP5/MOD2.5 with regard to AP600 calculations. Recent modifications in the areas of condensation wall heat transfer, interfacial heat transfer in the presence of noncondensibles, bubbly flow interfacial heat transfer, and time smoothing of both interfacial drag and interfacial heat transfer have improved the robustness, although more reliability is needed

  13. Design report on SCDAP/RELAP5 model improvements - debris bed and molten pool behavior

    International Nuclear Information System (INIS)

    Allison, C.M.; Rempe, J.L.; Chavez, S.A.

    1994-11-01

    The SCDAP/RELAP5/MOD3 computer code is designed to describe the overall reactor coolant system thermal-hydraulic response, core damage progression, and in combination with VICTORIA, fission product release and transport during severe accidents. Improvements for existing debris bed and molten pool models in the SCDAP/RELAP5/MOD3.1 code are described in this report. Model improvements to address (a) debris bed formation, heating, and melting; (b) molten pool formation and growth; and (c) molten pool crust failure are discussed. Relevant data, existing models, proposed modeling changes, and the anticipated impact of the changes are discussed. Recommendations for the assessment of improved models are provided

  14. Comparison of computer code calculations with FEBA test data

    International Nuclear Information System (INIS)

    Zhu, Y.M.

    1988-06-01

    The FEBA forced feed reflood experiments included base line tests with unblocked geometry. The experiments consisted of separate effect tests on a full-length 5x5 rod bundle. Experimental cladding temperatures and heat transfer coefficients of FEBA test No. 216 are compared with the analytical data postcalculated utilizing the SSYST-3 computer code. The comparison indicates a satisfactory matching of the peak cladding temperatures, quench times and heat transfer coefficients for nearly all axial positions. This agreement was made possible by the use of an artificially adjusted value of the empirical code input parameter in the heat transfer for the dispersed flow regime. A limited comparison of test data and calculations using the RELAP4/MOD6 transient analysis code are also included. In this case the input data for the water entrainment fraction and the liquid weighting factor in the heat transfer for the dispersed flow regime were adjusted to match the experimental data. On the other hand, no fitting of the input parameters was made for the COBRA-TF calculations which are included in the data comparison. (orig.) [de

  15. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Volume II. Program implementation

    International Nuclear Information System (INIS)

    1976-09-01

    This portion of the RELAP4/MOD5 User's Manual presents the details of setting up and entering the reactor model to be evaluated. The input card format and arrangement is presented in depth, including not only cards for data but also those for editing and restarting. Problem initalization including pressure distribution and energy balance is discussed. A section entitled ''User Guidelines'' is included to provide modeling recommendations, analysis and verification techniques, and computational difficulty resolution. The section is concluded with a discussion of the computer output form and format

  16. Qualification of the coupled RELAP5/PANTHER/COBRA code package for licensing applications

    International Nuclear Information System (INIS)

    Schneidesch, C.R.; Zhang Jinzhao

    2004-01-01

    A coupled thermal hydraulics-neutronics code package has been developed at Tractebel Engineering (TE), in which the best-estimate thermal-hydraulic system code, RELAP5/mod2.5, is coupled with the full three-dimensional reactor core kinetics code, PANTHER, via the dynamic data exchange interface, TALINK. The Departure from Nucleate Boiling Ratio (DNBR) is calculated by the sub-channel thermal-hydraulic analysis code COBRA-3C. The package provides the capability to accurately simulate the key physical phenomena in nuclear power plant accidents with strong asymmetric behaviours and system-core interactions. This paper presents the TE coupled code package and focuses on the methodology followed for qualifying it for licensing applications. The qualification of the coupling demonstrated the robustness achieved by the combined 3-D neutron kinetics/system T-H code package for transient simulations. The coupled TE code package has been qualified and will be used at Tractebel Engineering (TE) for analyzing asymmetric PWR accidents with strong core-system interactions

  17. Simulation of the first step of the coupling of the PARCS/RELAP5 codes to ANGRA 2 facility

    International Nuclear Information System (INIS)

    Del Pozzo, Andrea Sanchez; Andrade, Delvonei A. de; Sabundjian, Gaiane

    2015-01-01

    Since the Three Mile Island (1979) and Chernobyl (1986) accidents, the International Agency of Energy Atomic (IAEA) has worked with the authorities of other countries that use nuclear power plants in order to guarantee the safe of those facilities. The utilities have simulated design basic accidents to verify the integrity of the nuclear power plant to these events. However, after Fukushima accident in Japan (2011), the people have felt insecure and been afraid in relation to nuclear power plants. Today, the international and national organizations, such as the International Agency of Energy Atomic (IAEA) and Comissao Nacional de Energia Nuclear (CNEN), respectively, have worked very hard to prevent some accidents and transients in nuclear power plants in order to ensure the security of the general population. In case of accidents, as the Rod Ejection Accident (REA), it is very important to do the coupling between neutronic and thermal hydraulic areas of nuclear reactors. To solve this type of problem there is the coupling between PARCS/RELAP5 codes. However, to perform this analysis it is necessary to simulate three steps. The first step is simulating the steady state of one nuclear power plant by using RELAP5 code. The second step is to run the steady state of this reactor using the coupling PARCS/RELAP5, and the final step is simulating the REA of this facility with PARCS/RELAP5 coupling. The aim of this work is to show the results of the first step of this analysis, i.e., by means of simulation the steady state of Angra 2 nuclear power plant using RELAP5 version 3.3. In this case, the modeling from the core was more detailed than in the original version developed some years ago for Angra 2. The results obtained in this work were satisfactory. (author)

  18. Simulation of the first step of the coupling of the PARCS/RELAP5 codes to ANGRA 2 facility

    Energy Technology Data Exchange (ETDEWEB)

    Del Pozzo, Andrea Sanchez; Andrade, Delvonei A. de; Sabundjian, Gaiane, E-mail: delvonei@ipen.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Since the Three Mile Island (1979) and Chernobyl (1986) accidents, the International Agency of Energy Atomic (IAEA) has worked with the authorities of other countries that use nuclear power plants in order to guarantee the safe of those facilities. The utilities have simulated design basic accidents to verify the integrity of the nuclear power plant to these events. However, after Fukushima accident in Japan (2011), the people have felt insecure and been afraid in relation to nuclear power plants. Today, the international and national organizations, such as the International Agency of Energy Atomic (IAEA) and Comissao Nacional de Energia Nuclear (CNEN), respectively, have worked very hard to prevent some accidents and transients in nuclear power plants in order to ensure the security of the general population. In case of accidents, as the Rod Ejection Accident (REA), it is very important to do the coupling between neutronic and thermal hydraulic areas of nuclear reactors. To solve this type of problem there is the coupling between PARCS/RELAP5 codes. However, to perform this analysis it is necessary to simulate three steps. The first step is simulating the steady state of one nuclear power plant by using RELAP5 code. The second step is to run the steady state of this reactor using the coupling PARCS/RELAP5, and the final step is simulating the REA of this facility with PARCS/RELAP5 coupling. The aim of this work is to show the results of the first step of this analysis, i.e., by means of simulation the steady state of Angra 2 nuclear power plant using RELAP5 version 3.3. In this case, the modeling from the core was more detailed than in the original version developed some years ago for Angra 2. The results obtained in this work were satisfactory. (author)

  19. Validation of the RELAP5 code for the modeling of flashing-induced instabilities under natural-circulation conditions using experimental data from the CIRCUS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Kozmenkov, Y. [Helmholtz-Zentrum Dresden-Rossendorf e.V. (FZD), Institute of Safety Research, P.O.B. 510119, D-01324 Dresden (Germany); Institute of Physics and Power Engineering, Obninsk (Russian Federation); Rohde, U., E-mail: U.Rohde@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf e.V. (FZD), Institute of Safety Research, P.O.B. 510119, D-01324 Dresden (Germany); Manera, A. [Paul Scherrer Institute (Switzerland)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer We report about the simulation of flashing-induced instabilities in natural circulation systems. Black-Right-Pointing-Pointer Flashing-induced instabilities are of relevance for operation of pool-type reactors of small power at low pressure. Black-Right-Pointing-Pointer The RELAP5 code is validated against measurement data from natural circulation experiments. Black-Right-Pointing-Pointer The magnitude and frequency of the oscillations were reproduced in good agreement with the measurement data. - Abstract: This paper reports on the use of the RELAP5 code for the simulation of flashing-induced instabilities in natural circulation systems. The RELAP 5 code is intended to be used for the simulation of transient processes in the Russian RUTA reactor concept operating at atmospheric pressure with forced convection of coolant. However, during transient processes, natural circulation with flashing-induced instabilities might occur. The RELAP5 code is validated against measurement data from natural circulation experiments performed within the framework of a European project (NACUSP) on the CIRCUS facility. The facility, built at the Delft University of Technology in The Netherlands, is a water/steam 1:1 height-scaled loop of a typical natural-circulation-cooled BWR. It was shown that the RELAP5 code is able to model all relevant phenomena related to flashing induced instabilities. The magnitude and frequency of the oscillations were reproduced in a good agreement with the measurement data. The close correspondence to the experiments was reached by detailed modeling of all components of the CIRCUS facility including the heat exchanger, the buffer vessel and the steam dome at the top of the facility.

  20. Preliminary results of the seventh three-dimensional AER dynamic benchmark problem calculation. Solution with DYN3D and RELAP5-3D codes

    International Nuclear Information System (INIS)

    Bencik, M.; Hadek, J.

    2011-01-01

    The paper gives a brief survey of the seventh three-dimensional AER dynamic benchmark calculation results received with the codes DYN3D and RELAP5-3D at Nuclear Research Institute Rez. This benchmark was defined at the twentieth AER Symposium in Hanassari (Finland). It is focused on investigation of transient behaviour in a WWER-440 nuclear power plant. Its initiating event is opening of the main isolation valve and re-connection of the loop with its main circulation pump in operation. The WWER-440 plant is at the end of the first fuel cycle and in hot full power conditions. Stationary and burnup calculations were performed with the code DYN3D. Transient calculation was made with the system code RELAP5-3D. The two-group homogenized cross sections library HELGD05 created by HELIOS code was used for the generation of reactor core neutronic parameters. The detailed six loops model of NPP Dukovany was adopted for the seventh AER dynamic benchmark purposes. The RELAP5-3D full core neutronic model was coupled with 49 core thermal-hydraulic channels and 8 reflector channels connected with the three-dimensional model of the reactor vessel. The detailed nodalization of reactor downcomer, lower and upper plenum was used. Mixing in lower and upper plenum was simulated. The first part of paper contains a brief characteristic of RELAP5-3D system code and a short description of NPP input deck and reactor core model. The second part shows the time dependencies of important global and local parameters. (Authors)

  1. PCRELAP5: a visual graphic preprocessor for RELAP5

    International Nuclear Information System (INIS)

    Monaco, Daniel F.; Sabundjian, Gaianê

    2017-01-01

    The aim of this work is to develop PCRELAP5, a visual preprocessor for RELAP5, reducing time, effort and maintenance costs spent in new projects for RELAP5. This preprocessor allows user to draw new nuclear power plant nodalization in a completely interactive way, and input parameters for each node in a more user-friendly experience. Once parameters are changed on screen, the input cards of RELAP5 code are changed in real time. RELAP5 users will have a tool to reduce time and effort for new studies and existing projects. Therefore, this project proposes to significantly leverage studies related to nuclear accident analysis, making the RELAP5 code more user-friendly. In order to demonstrate this preprocessor capability, the CANON experiment will be used as an example. The PCRELAP5 preprocessor is being developed using Microsoft® Visual Studio® as a Microsoft® Excel® add-in, due to the low cost of distribution and maintenance, and also allowing new RELAP5 projects be leveraged by the MS Excel® flexibility. (author)

  2. PCRELAP5: a visual graphic preprocessor for RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Monaco, Daniel F.; Sabundjian, Gaianê, E-mail: monacod@usp.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The aim of this work is to develop PCRELAP5, a visual preprocessor for RELAP5, reducing time, effort and maintenance costs spent in new projects for RELAP5. This preprocessor allows user to draw new nuclear power plant nodalization in a completely interactive way, and input parameters for each node in a more user-friendly experience. Once parameters are changed on screen, the input cards of RELAP5 code are changed in real time. RELAP5 users will have a tool to reduce time and effort for new studies and existing projects. Therefore, this project proposes to significantly leverage studies related to nuclear accident analysis, making the RELAP5 code more user-friendly. In order to demonstrate this preprocessor capability, the CANON experiment will be used as an example. The PCRELAP5 preprocessor is being developed using Microsoft® Visual Studio® as a Microsoft® Excel® add-in, due to the low cost of distribution and maintenance, and also allowing new RELAP5 projects be leveraged by the MS Excel® flexibility. (author)

  3. RELAP5 and SIMMER-III code assessment on CIRCE decay heat removal experiments

    International Nuclear Information System (INIS)

    Bandini, Giacomino; Polidori, Massimiliano; Meloni, Paride; Tarantino, Mariano; Di Piazza, Ivan

    2015-01-01

    Highlights: • The CIRCE DHR experiments simulate LOHS+LOF transients in LFR systems. • Decay heat removal by natural circulation through immersed heat exchangers is investigated. • The RELAP5 simulation of DHR experiments is presented. • The SIMMER-III simulation of DHR experiments is presented. • The focus is on the transition from forced to natural convection and stratification in a large pool. - Abstract: In the frame of THINS Project of the 7th Framework EU Program on Nuclear Fission Safety, some experiments were carried out on the large scale LBE-cooled CIRCE facility at the ENEA/Brasimone Research Center to investigate relevant safety aspects associated with the removal of decay heat through heat exchangers (HXs) immersed in the primary circuit of a pool-type lead fast reactor (LFR), under loss of heat sink (LOHS) accidental conditions. The start-up and operation of this decay heat removal (DHR) system relies on natural convection on the primary side and then might be affected by coolant mixing and temperature stratification phenomena occurring in the LBE pool. The main objectives of the CIRCE experimental campaign were to verify the behavior of the DHR system under representative accidental conditions and provide a valuable database for the assessment of both CFD and system codes. The reproduced accidental conditions refer to a station blackout scenario, namely a protected LOHS and loss of flow (LOF) transient. In this paper the results of 1D RELAP5 and 2D SIMMER-III simulations are compared with the experimental data of more representative DHR transients T-4 and T-5 in order to verify the capability of these codes to reproduce both forced and natural convection conditions observed in the primary circuit and the right operation of the DHR system for decay heat removal. Both codes are able to reproduce the stationary conditions and with some uncertainties the transition to natural convection conditions until the end of the transient phase. The trend

  4. Uncertainty Analysis of RELAP5-3D

    Energy Technology Data Exchange (ETDEWEB)

    Alexandra E Gertman; Dr. George L Mesina

    2012-07-01

    As world-wide energy consumption continues to increase, so does the demand for the use of alternative energy sources, such as Nuclear Energy. Nuclear Power Plants currently supply over 370 gigawatts of electricity, and more than 60 new nuclear reactors have been commissioned by 15 different countries. The primary concern for Nuclear Power Plant operation and lisencing has been safety. The safety of the operation of Nuclear Power Plants is no simple matter- it involves the training of operators, design of the reactor, as well as equipment and design upgrades throughout the lifetime of the reactor, etc. To safely design, operate, and understand nuclear power plants, industry and government alike have relied upon the use of best-estimate simulation codes, which allow for an accurate model of any given plant to be created with well-defined margins of safety. The most widely used of these best-estimate simulation codes in the Nuclear Power industry is RELAP5-3D. Our project focused on improving the modeling capabilities of RELAP5-3D by developing uncertainty estimates for its calculations. This work involved analyzing high, medium, and low ranked phenomena from an INL PIRT on a small break Loss-Of-Coolant Accident as wall as an analysis of a large break Loss-Of- Coolant Accident. Statistical analyses were performed using correlation coefficients. To perform the studies, computer programs were written that modify a template RELAP5 input deck to produce one deck for each combination of key input parameters. Python scripting enabled the running of the generated input files with RELAP5-3D on INL’s massively parallel cluster system. Data from the studies was collected and analyzed with SAS. A summary of the results of our studies are presented.

  5. Countercurrent flow limitation model for RELAP5/MOD3

    International Nuclear Information System (INIS)

    Riemke, R.A.

    1991-01-01

    This paper reports on a countercurrent flow limitation model incorporated into the RELAP5/MOD3 system transient analysis code. The model is implemented in a manner similar to the RELAP5 chocking model. Simulations using air/water flooding test problem demonstrate the ability of the code to significantly improve its comparison to data when a flooding correlation is used

  6. SCDAP/RELAP5 applications to RCS natural circulation

    International Nuclear Information System (INIS)

    Bayless, P.D.

    1988-01-01

    The effects of natural circulation flows in the reactor coolant system during a TMLB' sequence were investigated. Both in-vessel circulation and hot leg countercurrent flow were modeled in the Surry nuclear power plant using the SCDAP/RELAP5 computer code. The transient was analyzed until after fuel rod relocation had begun. The delays in the onset of relocation resulting from the natural circulation flows were not significant compared to SCDAP/RELAP5 calculations without natural circulation modeled, but were large compared to the analyses presented in NUREG-1150. The most significant aspect of the natural circulations flows was the heating of ex-vessel structures. Surge line failure is likely to occur before the vessel is breached by the molten core, while steam generator tube failure is not expected

  7. Application of RELAP/SCDAPSIM with integrated uncertainty options to research reactor systems thermal hydraulic analysis

    International Nuclear Information System (INIS)

    Allison, C.M.; Hohorst, J.K.; Perez, M.; Reventos, F.

    2010-01-01

    The RELAP/SCDAPSIM/MOD4.0 code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed as part of the international SCDAP Development and Training Program (SDTP). RELAP/SCDAPSIM/MOD4.0, which is the first version of RELAP5 completely rewritten to FORTRAN 90/95/2000 standards, uses publicly available RELAP5 and SCDAP models in combination with advanced programming and numerical techniques and other SDTP-member modeling/user options. One such member developed option is an integrated uncertainty analysis package being developed jointly by the Technical University of Catalonia (UPC) and Innovative Systems Software (ISS). This paper briefly summarizes the features of RELAP/SCDAPSIM/MOD4.0 and the integrated uncertainty analysis package, and then presents an example of how the integrated uncertainty package can be setup and used for a simple pipe flow problem. (author)

  8. Development of LabVIEW web-based simulator for RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Luiz A.; Torres, Walmir M.; Sabundjian, Gaiane; Andrade, Delvonei A.; Belchior Junior, Antonio; Umbehaun, Pedro E.; Conti, Thadeu N.; Mesquita, Roberto N. de; Masotti, Paulo H.F.; Angelo, Gabriel, E-mail: lamacedo@ipen.b, E-mail: wmtorres@ipen.b, E-mail: gdjian@ipen.b, E-mail: delvonei@ipen.b, E-mail: abelchior@ipen.b, E-mail: umbehaun@ipen.b, E-mail: tnconti@ipen.b, E-mail: rnavarro@ipen.b, E-mail: , E-mail: masotti@ipen.b, E-mail: gabriel.angelo@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This work presents the development of a LabVIEW web-based simulator using the output results of the best estimate nuclear system analysis code, RELAP5, for graphical user interfaces and web-casting. A numerical based model designed for natural circulation studies on the thermal hydraulic experimental facility called Natural Circulation Circuit, was developed with RELAP5 code. Specific output results from RELAP5 simulation are displayed in a user friendly graphical format. The temperatures are shown as a function of time in a XY graphic. Temperatures, levels and void fractions are displayed in color-coded scale which change in time on the graphical interface representing the circuit. An alarm is set for the case of onset boiling temperature occurrence at the heater outlet. This simulator allows an easy visual understanding of the thermal hydraulic circuit behavior. It can be shared, via Web, with researchers in any geographical location and, at the same time, it can be used in learning for distance educational purposes. In future work, this LabVIEW simulator will be coupled with RELAP5 code through dll's. Simultaneous graphical displaying and code calculations will be possible. Results are presented and discussed. (author)

  9. Development of LabVIEW web-based simulator for RELAP5

    International Nuclear Information System (INIS)

    Macedo, Luiz A.; Torres, Walmir M.; Sabundjian, Gaiane; Andrade, Delvonei A.; Belchior Junior, Antonio; Umbehaun, Pedro E.; Conti, Thadeu N.; Mesquita, Roberto N. de; Masotti, Paulo H.F.; Angelo, Gabriel

    2011-01-01

    This work presents the development of a LabVIEW web-based simulator using the output results of the best estimate nuclear system analysis code, RELAP5, for graphical user interfaces and web-casting. A numerical based model designed for natural circulation studies on the thermal hydraulic experimental facility called Natural Circulation Circuit, was developed with RELAP5 code. Specific output results from RELAP5 simulation are displayed in a user friendly graphical format. The temperatures are shown as a function of time in a XY graphic. Temperatures, levels and void fractions are displayed in color-coded scale which change in time on the graphical interface representing the circuit. An alarm is set for the case of onset boiling temperature occurrence at the heater outlet. This simulator allows an easy visual understanding of the thermal hydraulic circuit behavior. It can be shared, via Web, with researchers in any geographical location and, at the same time, it can be used in learning for distance educational purposes. In future work, this LabVIEW simulator will be coupled with RELAP5 code through dll's. Simultaneous graphical displaying and code calculations will be possible. Results are presented and discussed. (author)

  10. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Volume II. Program implementation

    International Nuclear Information System (INIS)

    1976-06-01

    A discussion is presented of the use of the RELAP4/MOD5 computer program in simulating the thermal-hydraulic behavior of light-water reactor systems when subjected to postulated transients such as a LOCA, pump failure, or nuclear excursion. The volume is divided into main sections which cover: (1) program description, (2) input data, (3) problem initialization, (4) user guidelines, (5) output discussion, (6) source program description, (7) implementation requirements, (8) data files, (9) description of PLOTR4M, (10) description of STH20, (11) summary flowchart, (12) sample problems, (13) problem definition, and (14) problem input

  11. A comparison of the RELAP5/MOD3 code with the IIST natural circulation experiments

    International Nuclear Information System (INIS)

    Ferng, Y.M.; Lee, C.H.

    1995-01-01

    A series of experiments dealing with variable secondary-side cooling conditions have been conducted at the IIST facility, including the natural circulation experiments under the secondary-side conditions of normal feedwater, loss of feedwater, and full of air. Different cooling conditions at the secondary side directly affect the primary-to-secondary heat transfer and then may influence the heat removal capability of natural circulation in the primary system. The corresponding analytical work is performed using the RELAP5/MOD3 code. Good agreement is reached both qualitatively and quantitatively between the experimental data and calculated results, demonstrating the satisfactory assessment of RELAP5/MOD3 code compared with the IIST natural circulation experiments. The cooling conditions at the secondary side have no significant effect on the heat removal capability of natural circulation as long as sufficient coolant exists on the steam generator secondary side, based on current IIST data and analytical results. Continuous increase of the core temperature and system pressure is also demonstrated experimentally and analytically in the test with the secondary side dry for the sake of deficient heat transfer capability at the steam generator secondary system

  12. RELAP5 assessment: conclusions and user guidelines

    International Nuclear Information System (INIS)

    Kmetyk, L.N.

    1984-10-01

    The RELAP5 independent assessment project at Sandia National Laboratories is part of an overall effort funded by the NRC to determine the ability of various systems codes to predict the detailed thermal/hydraulic response of LWRs during accident and off-normal conditions. The RELAP5/MOD1 code has been assessed at Sandia against a variety of test data from both integral and separate effects test facilities. All these analyses have been documented in detail in individual topical reports; in this paper we attempt to evaluate the overall code performance by comparing results from many different calculations, and to offer other users some guidelines based on our experience to date

  13. Evaluation of reflooding effects on an overheated boiling water reactor core in a small steam-line break accident using MAAP, MELCOR, and SCDAP/RELAP5 computer codes

    International Nuclear Information System (INIS)

    Lindholm, I.; Pekkarinen, E.; Sjoevall, H.

    1995-01-01

    Selected core reflooding situations were investigated in the case of a Finnish boiling water reactor with three severe accident analysis computer codes (MAAP, MELCOR, and SCDAP/RELAP5). The unmitigated base case accident scenario was a 10% steam-line break without water makeup to the reactor pressure vessel initially. The pumping of water to the core was started with the auxiliary feed water system when the maximum fuel cladding temperature reached 1,500 K. The auxiliary feedwater system pumps water (temperature 303 K) through the core spray spargers (core spray) on the top of the core and through feedwater nozzles to the downcomer (downcomer injection). The scope of the study was restricted to cases where the overheated core was still geometrically intact at the start of the reflooding. The following different core reflooding situations were investigated: (1) auxiliary feedwater injection to core spray (45 kg/s); (2) auxiliary feedwater injection to downcomer (45 kg/s); (3) auxiliary feedwater injection to downcomer (45 kg/s) and to core spray (45 kg/s); (4) no reflooding of the core. All the three codes predicted debris formation after the water addition, and in all MAAP and MELCOR reflooding results the core was quenched. The major difference between the code predictions was in the amount of H 2 produced, though the trends in H 2 production were similar. Additional steam production during the quenching process accelerated the oxidation in the unquenched parts of the core. This result is in accordance with several experimental observations

  14. RELAP5/MOD3.3 Analysis of the Loss of External Power Event with Safety Injection Actuation

    Directory of Open Access Journals (Sweden)

    Andrej Prošek

    2018-01-01

    Full Text Available The code assessment typically comprises basic tests cases, separate effects test, and integral effects tests. On the other hand, the thermal hydraulic system codes like RELAP5/MOD3.3 are primarily intended for simulation of transients and accidents in light water reactors. The plant measured data come mostly from startup tests and operational events. Also, for operational events the measured plant data may not be sufficient to explain all details of the event. The purpose of this study was therefore besides code assessment to demonstrate that simulations can be very beneficial for deep understanding of the plant response and further corrective measures. The abnormal event with reactor trip and safety injection signal actuation was simulated with the latest RELAP5/MOD3.3 Patch 05 best-estimate thermal hydraulic computer code. The measured and simulated data agree well considering the major plant system responses and operator actions. This suggests that the RELAP5 code simulation is good representative of the plant response and can complement not available information from plant measured data. In such a way, an event can be better understood.

  15. Towards advanced code simulators

    International Nuclear Information System (INIS)

    Scriven, A.H.

    1990-01-01

    The Central Electricity Generating Board (CEGB) uses advanced thermohydraulic codes extensively to support PWR safety analyses. A system has been developed to allow fully interactive execution of any code with graphical simulation of the operator desk and mimic display. The system operates in a virtual machine environment, with the thermohydraulic code executing in one virtual machine, communicating via interrupts with any number of other virtual machines each running other programs and graphics drivers. The driver code itself does not have to be modified from its normal batch form. Shortly following the release of RELAP5 MOD1 in IBM compatible form in 1983, this code was used as the driver for this system. When RELAP5 MOD2 became available, it was adopted with no changes needed in the basic system. Overall the system has been used for some 5 years for the analysis of LOBI tests, full scale plant studies and for simple what-if studies. For gaining rapid understanding of system dependencies it has proved invaluable. The graphical mimic system, being independent of the driver code, has also been used with other codes to study core rewetting, to replay results obtained from batch jobs on a CRAY2 computer system and to display suitably processed experimental results from the LOBI facility to aid interpretation. For the above work real-time execution was not necessary. Current work now centers on implementing the RELAP 5 code on a true parallel architecture machine. Marconi Simulation have been contracted to investigate the feasibility of using upwards of 100 processors, each capable of a peak of 30 MIPS to run a highly detailed RELAP5 model in real time, complete with specially written 3D core neutronics and balance of plant models. This paper describes the experience of using RELAP5 as an analyzer/simulator, and outlines the proposed methods and problems associated with parallel execution of RELAP5

  16. RELAP5/MOD2: for PWR transient analysis

    International Nuclear Information System (INIS)

    Ransom, V.H.

    1983-01-01

    RELAP5 is a light water reactor system transient simulation code for use in nuclear plant safety analysis. Development of a new version, RELAP5/MOD2, has been completed and will be released to the United States Nuclear Regulatory Commission during September of 1983. The new and improved modeling capability of RELAP5/MOD2 is described and some developmental assessment results are presented. The future plans for extension to severe accident modeling are briefly discussed

  17. Application of RELAP5-3D code for thermal analysis of the ADS reactor core

    International Nuclear Information System (INIS)

    Fernandes, Gustavo Henrique Nazareno

    2018-01-01

    Nuclear power is essential to supply global energy demand. Therefore, in order to use nuclear fuel more efficiently, more efficient nuclear reactors technologies researches have been intensified, such as hybrid systems, composed of particle accelerators coupled into nuclear reactors. In order to add knowledge to such studies, an innovative reactor design was considered where the RELAP5-3D thermal-hydraulic analysis code was used to perform a thermal analysis of the core, either in stationary operation or in situations transitory. The addition of new kind of coolants, such as, liquid salts, among them Flibe, lead, lead-bismuth, sodium, lithium-bismuth and lithium-lead was an important advance in this version of the code, making possible to do the thermal simulation of reactors that use these types of coolants. The reactor, object of study in this work, is an innovative reactor, due to its ability to operate in association with an Accelerator Driven System (ADS), considered a predecessor system of the next generation of nuclear reactors (GEN IV). The reactor selected was the MYRRHA (Multi-purpose Hybrid Research Reactor for High tech Applications) due to the availability of data to perform the simulation. In the modeling of the reactor with the code RELAP5-3D, the core was simulated using nodules with 1, 7, 15 and 51 thermohydraulic channels and eutectic lead-bismuth (LBE) as coolant. The parameters, such as, pressure, mass flow and coolant and heat structure temperature were analyzed. In addition, the thermal behavior of the core was evaluated by varying the type of coolant (sodium) in substitution for the LBE of the original design using the model with 7 thermohydraulic channels. The results of the steady-state calculations were compared with data from the literature and the proposed models were verified certifying the ability of the RELAP5-3D code to simulate this innovative reactor. After this step, it was analysed cases of transients with loss of coolant flow

  18. Evaluation of RELAP5 MOD 3.1.1 code with GIRAFFE Test Facility: Phase 1, Step 2 nitrogen venting tests

    International Nuclear Information System (INIS)

    Boyer, B.D.; Slovik, G.C.; Rohatgl, U.S.

    1995-01-01

    The Simplified Boiling Water Reactor (SBWR) proposed by General Electric (GE) is an advanced light water reactor (ALWR) design that utilizes passive safety systems. The PCCS is a series of heat exchangers submerged in water and open to the containment. Since the containment is inerted with nitrogen during normal operation, the PCCS must condense the steam in the presence of noncondensable gases during an accident. To model the transient behavior of the SBWR with a system code, the code should properly simulate the expected phenomena. To validate the applicability of RELAP5 MOD 3.1.1, the data from three Phase 1, Step 2 nitrogen venting tests at Toshiba's Gravity-Driven Integral Full-Height Test for Passive Heat Removal facility and RELAP5 calculations of these tests were compared. The comparison of the GIRAFFE data against the results from the RELAP5 calculations showed that it can predict condensation and gas purging phenomena occurring in the long-term decay heat rejection phase. In this phase of the transient, condensation in the PCCS is the only means to reject heat from the SBWR containment. In the two tests where the nitrogen purge vent line was at its deepest submergence in the Suppression Pool (SIP), the RELAP5 results mirrored the behavior of the containment pressures and of the water levels in the Horizontal Vent (HV) and the nitrogen purge line tube of the GIRAFFE data. However, in the test with the shallowest purge line submergence, there was appreciable direct contact condensation on the pool surface of the HV despite modeling efforts to deter these phenomena. This surface condensation, unobserved in the GIRAFFE tests, was a major cause of RELAP5 predicting early containment depressurization and the subsequent early rise in HV and nitrogen purge line water levels. The present RELAP5 MOD3.1.1 interfacial heat and mass transfer model does not properly degrade direct contact steam condensation in the presence of noncondensable gases sitting on a pool

  19. Interim results of the sixth three-dimensional AER dynamic benchmark problem calculation. Solution of problem with DYN3D and RELAP5-3D codes

    International Nuclear Information System (INIS)

    Hadek, J.; Kral, P.; Macek, J.

    2001-01-01

    The paper gives a brief survey of the 6 th three-dimensional AER dynamic benchmark calculation results received with the codes DYN3D and RELAPS-3D at NRI Rez. This benchmark was defined at the 10 th AER Symposium. Its initiating event is a double ended break in the steam line of steam generator No. I in a WWER-440/213 plant at the end of the first fuel cycle and in hot full power conditions. Stationary and burnup calculations as well as tuning of initial state before the transient were performed with the code DYN3D. Transient calculations were made with the system code RELAPS-3D.The KASSETA library was used for the generation of reactor core neutronic parameters. The detailed six loops model of NPP Dukovany was adopted for the 6 th AER dynamic benchmark purposes. The RELAPS-3D full core neutronic model was connected with seven coolant channels thermal-hydraulic model of the core (Authors)

  20. Recent SCDAP/RELAP5 improvements for BWR severe accident simulations

    International Nuclear Information System (INIS)

    Griffin, F.P.

    1995-01-01

    A new model for the SCDAP/RELAP5 severe accident analysis code that represents the control blade and channel box structures in a boiling water reactor (BWR) has been under development since 1991. This model accounts for oxidation, melting, and relocation of these structures, including the effects of material interactions between B 4 C, stainless steel, and Zircaloy. This paper describes improvements that have been made to the BWR control blade/channel box model during 1994 and 1995. These improvements include new capabilities that represent the relocation of molten material in a more realistic manner and modifications that improve the usability of the code by reducing the frequency of code failures. This paper also describes a SCDAP/RELAP5 assessment calculation for the Browns Ferry Nuclear Plant design based upon a short-term station blackout accident sequence

  1. Progress on B4C control rod modeling in RELAP/SCDAPSIM with application to quench and Phebus

    International Nuclear Information System (INIS)

    Kawahara, Keisuke; Hohorst, Judith K.; Allison, Chris M.

    2014-01-01

    The RELAP/SCDAPSIM code is designed to predict the behavior of reactor systems during normal and accident conditions. RELAP/SCDAPSIM/MOD3.5 is an experimental version of the code with the most advanced fuel and severe accident behavior models and correlations. It includes modeling improvements that were specifically added to support (a) the ongoing experimental severe accident programs in Europe and Japan and (b) the analysis and assessment activities related to the accident at the Fukushima Daiichi NPS. One of the improved models describes the behavior of cylindrical B 4 C control rods used in selected PWR designs and in integral experiments used to assess the heating and melting of PWR, BWR, and VVER assemblies. It replaces an older model that was originally developed by the US Nuclear Regulatory Commission in the mid- 1980's. It includes a combination of new and improved models and correlations to more accurately describe (a) eutectic reactions between Zircaloy, B 4 C, and stainless steel, (b) oxidation for B 4 C, Zircaloy, and stainless steel, and (c) the effects of the gap between the Zircaloy guide tube and the stainless steel sheath surrounding B 4 C pellets used in many control rod designs. This paper will discuss the development of the new model and validation of the model using the PHEBUS B 4 C test, FPT-3, and the KIT quench experiments with a central B 4 C control rod. (authors)

  2. Improvement of the RELAP5 subcooled boiling model for low pressure conditions

    International Nuclear Information System (INIS)

    Koncar, B.; Mavko, B.

    2000-01-01

    The RELAP5/MOD3.2.2 Gamma code was assessed against low pressure subcooled boiling experiments performed by Zeitoun and Shoukri [1] in a vertical annulus. The predictions of subcooled boiling bubbly flow showed that the present version of the RELAP5 code underestimates the void fraction growth along the tube. To improve the void fraction prediction at low pressure conditions a set of model changes is proposed, which includes modifications of bubbly-slug transition criterion, drift-flux model, interphase heat transfer coefficient and wall evaporation modeling. The improved experiment predictions with the modified RELAP5 code are presented and analysed. (author)

  3. Validation of containment thermal hydraulic computer codes for VVER reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jiri Macek; Lubomir Denk [Nuclear Research Institute Rez plc Thermal-Hydraulic Analyses Department CZ 250 68 Husinec-Rez (Czech Republic)

    2005-07-01

    Full text of publication follows: The Czech Republic operates 4 VVER-440 units, two VVER-1000 units are being finalized (one of them is undergoing commissioning). Thermal-hydraulics Department of the Nuclear Research Institute Rez performs accident analyses for these plants using a number of computer codes. To model the primary and secondary circuits behaviour the system codes ATHLET, CATHARE, RELAP, TRAC are applied. Containment and pressure-suppression system are modelled with COCOSYS and MELCOR codes, the reactor power calculations (point and space-neutron kinetics) are made with DYN3D, NESTLE and CDF codes (FLUENT, TRIO) are used for some specific problems.An integral part of the current Czech project 'New Energy Sources' is selection of a new nuclear source. Within this and the preceding projects financed by the Czech Ministry of Industry and Trade and the EU PHARE, the Department carries and has carried out the systematic validation of thermal-hydraulic and reactor physics computer codes applying data obtained on several experimental facilities as well as the real operational data. One of the important components of the VVER 440/213 NPP is its containment with pressure suppression system (bubble condenser). For safety analyses of this system, computer codes of the type MELCOR and COCOSYS are used in the Czech Republic. These codes were developed for containments of classic PWRs or BWRs. In order to apply these codes for VVER 440 systems, their validation on experimental facilities must be performed.The paper provides concise information on these activities of the NRI and its Thermal-hydraulics Department. The containment system of the VVER 440/213, its functions and approaches to solution of its safety is described with definition of acceptance criteria. A detailed example of the containment code validation on EREC Test facility (LOCA and MSLB) and the consequent utilisation of the results for a real NPP purposes is included. An approach to

  4. A review of MAAP4 code structure and core T/H model

    International Nuclear Information System (INIS)

    Song, Yong Mann; Park, Soo Yong

    1998-03-01

    The modular accident analysis program (MAAP) version 4 is a computer code that can simulate the response of LWR plants during severe accident sequences and includes models for all of the important phenomena which might occur during accident sequences. In this report, MAAP4 code structure and core thermal hydraulic (T/H) model which models the T/H behavior of the reactor core and the response of core components during all accident phases involving degraded cores are specifically reviewed and then reorganized. This reorganization is performed via getting the related models together under each topic whose contents and order are same with other two reports for MELCOR and SCDAP/RELAP5 to be simultaneously published. Major purpose of the report is to provide information about the characteristics of MAAP4 core T/H models for an integrated severe accident computer code development being performed under the one of on-going mid/long-term nuclear developing project. The basic characteristics of the new integrated severe accident code includes: 1) Flexible simulation capability of primary side, secondary side, and the containment under severe accident conditions, 2) Detailed plant simulation, 3) Convenient user-interfaces, 4) Highly modularization for easy maintenance/improvement, and 5) State-of-the-art model selection. In conclusion, MAAP4 code has appeared to be superior for 3) and 4) items but to be somewhat inferior for 1) and 2) items. For item 5), more efforts should be made in the future to compare separated models in detail with not only other codes but also recent world-wide work. (author). 17 refs., 1 tab., 12 figs

  5. Development, assessment, licensing, and application of RELAP5YA at Yankee Atomic Electric Company

    International Nuclear Information System (INIS)

    Husain, A.

    1984-01-01

    Since 1975, Yankee Atomic Electric Company (YAEC) has been licensed to perform LOCA analyses (large and small breaks) for PWRs. The methods are based upon the WREM package, comprised of RELAP4-MOD 3, RELAP4-FLOOD, and TOODEE-2EM. Significant efforts were expended to compare WREM models against Appendix K criteria, and to incorporate changes for compliance with the criteria and for improved representation of LOCA phenomena. /SUP 2,3,4/ This internalized capability has been used extensively for licensing the Yankee and Maine Yankee plants, and for timely resolution of LOCA issues which frequently arose. The value of this internalized analysis capability was well recognized by the Yankee management. In 1979, Yankee embarked upon another LOCA Methods Development Program. One objective was to remove extra conservatisms inherent in older codes to provide additional operational flexibility for our plants. Also, we needed a code which could be used in a production mode to provide realistic response for off-normal conditions to be used in operator training and emergency guideline assessment. This program resulted in the development of RELAP5YA. The development, assessment, licensing, and application of RELAP5YA at YAEC is briefly described in this paper

  6. Gest-sip1 experiments and post-test calculations with the relap5 code

    International Nuclear Information System (INIS)

    Achilli, A.; Cattadori, G.; Ferri, R.; Gandolfi, S.; Bianchi, F.; Meloni, P.

    2001-01-01

    The SIP-1 apparatus (Sistema di Iniezione Passiva) was conceived, designed, numerically simulated and tested by the SIET company as an innovative depressurization and make-up device for the New Generation LWRs. In particular it is suitable to cope with those accidents where pressure in the circuit must be dumped to allow low pressure injection systems to intervene. The main peculiarity of SIP-1 is the capability of de-pressurizing a system by cold water injection, rather than by discharging mass to the outlet, as in the common depressurization systems. ENEA sponsored all the research activity, starting from the SIP-1 design, its numerical simulation with the Relap5 code, the realisation of an experimental facility up to the test execution and post-test calculations. An experimental campaign on the GEST-SIP1 facility was performed in July 2000. The facility is mainly constituted by a U-tube Steam Generator which a proper model of SIP-1 apparatus is connected to. A series of Small Break LOCAs was simulated by varying the break size and different steady conditions were investigated to verify the stability of SIP-1, the lack of unexpected interventions and the actuation modalities. This paper deals with the description of the GEST-SIP1 experimental facility, the SIP-1 operating principles, the most meaningful results of the tests and the capability of the Relap5 code in reproducing phenomena and events. (author)

  7. RELAP5/MOD3.2 investigation of loss of in-house supply power for WWER 1000/320V

    International Nuclear Information System (INIS)

    Gencheva, R.; Pavlova, M.; Groudev, P.

    2001-01-01

    This paper discusses the results of the thermal-hydraulic investigations of the 'Loss of in-house supply power' accident at the Kozloduy NPP Unit 6. The RELAP5/MOD3.2 computer code has been used to stimulate the loss of in-house supply power accident in a WWER 1000 Nuclear Power Plant model. This model was developed at the Institute for Nuclear Research and Nuclear Energy for analyses of operational occurrences, abnormal events and design basis scenarios. It will provide a significant analytical capability for the Bulgarian technical specialists located at the Kozloduy NPP. The criteria used in selecting transient are: importance to safety, availability and suitability of data followed by suitability for RELAP5 code validation. The investigation of 'Loss of normal and reverse AC power' is a process that compares the analytical results obtained by RELAP5/MOD3.2 model of the WWER 1000 against experimental transient data obtained from Kozloduy NPP Unit 6. The comparisons between the RELAP5 results and the test data indicate good agreement

  8. Reformulation RELAP5-3D in FORTRAN 95 and Results

    International Nuclear Information System (INIS)

    Mesina, George L.

    2010-01-01

    RELAP5-3D is a nuclear power plant code used worldwide for safety analysis, design, and operator training. In keeping with ongoing developments in the computing industry, we have re-architected the code in the FORTRAN 95 language, the current, fully-available, FORTRAN language. These changes include a complete reworking of the database and conversion of the source code to take advantage of new constructs. The improvements and impacts to the code are manifold. It is a completely machine-independent code that produces machine independent fluid property and plot files and expands to the exact size needed to accommodate the user's input. Runtime is generally better for larger input models. Other impacts of code conversion are improved code readability, reduced maintenance and development time, increased adaptability to new computing platforms, and increased code longevity. The conversion methodology, code improvements and testing upgrades are presented in a manner that will be useful to future conversion projects for other such large codes. Comparison between the pre- and post-conversion code are made on the basis of code metrics and code performance.

  9. RELAP5/MOD2 models and correlations

    International Nuclear Information System (INIS)

    Dimenna, R.A.; Larson, J.R.; Johnson, R.W.; Larson, T.K.; Miller, C.S.; Streit, J.E.; Hanson, R.G.; Kiser, D.M.

    1988-08-01

    A review of the RELAP5/MOD2 computer code has been performed to assess the basis for the models and correlations comprising the code. The review has included verification of the original data base, including thermodynamic, thermal-hydraulic, and geothermal conditions; simplifying assumptions in implementation or application; and accuracy of implementation compared to documented descriptions of each of the models. An effort has been made to provide the reader with an understanding of what is in the code and why it is there and to provide enough information that an analyst can assess the impact of the correlation or model on the ability of the code to represent the physics of a reactor transient. Where assessment of the implemented versions of the models or correlations has been accomplished and published, the assessment results have been included

  10. Thermal-hydraulic modelling of the SAFARI-1 research reactor using RELAP/SCDAPSIM/MOD3.4

    International Nuclear Information System (INIS)

    Sekhri, Abdelkrim; Graham, Andy; D'Arcy, Alan; Oliver, Melissa

    2008-01-01

    The SAFARI-1 reactor is a tank-in-pool MTR type research reactor operated at a nominal core power of 20 MW. It operates exclusively in the single phase liquid water regime with nominal water and fuel temperatures not exceeding 100 deg. C. RELAP/SCDAPSIM/MOD3.4 is a Best Estimate Code for light water reactors as well as for low pressure transients, as part of the code validation was done against low pressure facilities and research reactor experimental data. The code was used to simulate SAFARI-1 in normal and abnormal operation and validated against the experimental data in the plant and was used extensively in the upgrading of the Safety Analysis Report (SAR) of the reactor. The focus of the following study is the safety analysis of the SAFARI-1 research reactor and describes the thermal hydraulic modelling and analysis approach. Particular emphasis is placed on the modelling detail, the application of the no-boiling rule and predicting the Onset of Nucleate Boiling and Departure from Nucleate Boiling under Loss of Flow conditions. Such an event leads the reactor to switch to a natural convection regime which is an adequate mode to maintain the clad and fuel temperature within the safety margin. It is shown that the RELAP/SCDAPSIM/MOD3.4 model can provide accurate predictions as long as the clad temperature remains below the onset of nucleate boiling temperature and the DNB ratio is greater than 2. The results are very encouraging and the model is shown to be appropriate for the analysis of SAFARI-1 research reactor. (authors)

  11. Relap5/mod2 post-test calculation of a loss of feedwater experiment at the Pactel test facility

    Energy Technology Data Exchange (ETDEWEB)

    Protze, M. [Siemens-KWU, Erlangen (Germany)

    1995-12-31

    Post-test calculations for verification purposes of the thermal hydraulic code RELAP5/MOD2 are of fundamental importance for the licensing procedure. The RELAP5/MOD2 code has a large international assessment base regarding western PWR. WWER-reactors are russian designed PWRs with some specific differences compared with the western PWR`s, especially the horizontal steam generators. For that reason some post-test calculations have to be performed to verify the RELAP5/MOD2 code for these WWER typical phenomena. The impact of the horizontal steam generators on the accident behaviour during transients or pipe ruptures on the secondary side is significant. The nodalization of the test facility PACTEL was chosen equally to WWER plant nodalization to verify the use of a coarse modelling of the steam generator secondary side for analyses of transient with decreasing water level in the SG secondary side. The calculational results showed a good compliance to the test results, demonstrating the correct use of a coarse nodalization. To sum up, the RELAP5/ MOD2 results met the test results appropriately thereby the RELAP5/ MOD2 code is validated for analyses of transients with decreasing water level in a horizontal steam generator secondary side. (orig.). 4 refs.

  12. Relap5/mod2 post-test calculation of a loss of feedwater experiment at the Pactel test facility

    Energy Technology Data Exchange (ETDEWEB)

    Protze, M [Siemens-KWU, Erlangen (Germany)

    1996-12-31

    Post-test calculations for verification purposes of the thermal hydraulic code RELAP5/MOD2 are of fundamental importance for the licensing procedure. The RELAP5/MOD2 code has a large international assessment base regarding western PWR. WWER-reactors are russian designed PWRs with some specific differences compared with the western PWR`s, especially the horizontal steam generators. For that reason some post-test calculations have to be performed to verify the RELAP5/MOD2 code for these WWER typical phenomena. The impact of the horizontal steam generators on the accident behaviour during transients or pipe ruptures on the secondary side is significant. The nodalization of the test facility PACTEL was chosen equally to WWER plant nodalization to verify the use of a coarse modelling of the steam generator secondary side for analyses of transient with decreasing water level in the SG secondary side. The calculational results showed a good compliance to the test results, demonstrating the correct use of a coarse nodalization. To sum up, the RELAP5/ MOD2 results met the test results appropriately thereby the RELAP5/ MOD2 code is validated for analyses of transients with decreasing water level in a horizontal steam generator secondary side. (orig.). 4 refs.

  13. Simulation of the postulated stopping accident of the bombs of the primary circuit of Angra 2 with the code RELAP5/MOD3.2

    International Nuclear Information System (INIS)

    Andrade, Delvonei A.; Sabundjian, Gaiane; Madeira, Alzira A.; Pereira, Luiz Carlos M.; Borges, Ronaldo C.; Lapa, Nelbia S.

    2001-01-01

    This work presents the simulation of an anticipated transient for Angra 2 Nuclear Power Plant, where the coast down of the four reactor coolant pumps is verified. The best estimate thermal hydraulic system code RELAP5/MOD3.2 was used on this frame. A multi-purpose nodalization of Angra 2 was developed to simulate a comprehensive set of operational transients and accidents with RELAP5/MOD3.2 code. The overall objective of this work is to provide independent accident evaluation and further operational behavior follow-up to support the licensing process of the plant. (author)

  14. Uncertainty analysis of minimum vessel liquid inventory during a small-break LOCA in a B ampersand W Plant: An application of the CSAU methodology using the RELAP5/MOD3 computer code

    International Nuclear Information System (INIS)

    Ortiz, M.G.; Ghan, L.S.

    1992-12-01

    The Nuclear Regulatory Commission (NRC) revised the emergency core cooling system licensing rule to allow the use of best estimate computer codes, provided the uncertainty of the calculations are quantified and used in the licensing and regulation process. The NRC developed a generic methodology called Code Scaling, Applicability, and Uncertainty (CSAU) to evaluate best estimate code uncertainties. The objective of this work was to adapt and demonstrate the CSAU methodology for a small-break loss-of-coolant accident (SBLOCA) in a Pressurized Water Reactor of Babcock ampersand Wilcox Company lowered loop design using RELAP5/MOD3 as the simulation tool. The CSAU methodology was successfully demonstrated for the new set of variants defined in this project (scenario, plant design, code). However, the robustness of the reactor design to this SBLOCA scenario limits the applicability of the specific results to other plants or scenarios. Several aspects of the code were not exercised because the conditions of the transient never reached enough severity. The plant operator proved to be a determining factor in the course of the transient scenario, and steps were taken to include the operator in the model, simulation, and analyses

  15. RELAP5 Prediction of Transient Tests in the RD-14 Test Facility

    International Nuclear Information System (INIS)

    Lee, Sukho; Kim, Manwoong; Kim, Hho-Jung; Lee, John C.

    2005-01-01

    Although the RELAP5 computer code has been developed for best-estimate transient simulation of a pressurized water reactor and its associated systems, it could not assess the thermal-hydraulic behavior of a Canada deuterium uranium (CANDU) reactor adequately. However, some studies have been initiated to explore the applicability for simulating a large-break loss-of-coolant accident in CANDU reactors. In the present study, the small-reactor inlet header break test and the steam generator secondary-side depressurization test conducted in the RD-14 test facility were simulated with the RELAP5/MOD3.2.2 code to examine its extended capability for all the postulated transients and accidents in CANDU reactors. The results were compared with experimental data and those of the CATHENA code performed by Atomic Energy of Canada Limited.In the RELAP5 analyses, the heated sections in the facility were simulated as a multichannel with five pipe models, which have identical flow areas and hydraulic elevations, as well as a single-pipe model.The results of the small-reactor inlet header break and the steam generator secondary-side depressurization simulations predicted experimental data reasonably well. However, some discrepancies in the depressurization of the primary heat transport system after the header break and consequent time delay of the major phenomena were observed in the simulation of the small-reactor inlet header break test

  16. Thermal hydraulic analysis of the IPR-R1 TRIGA research reactor using a RELAP5 model

    International Nuclear Information System (INIS)

    Costa, Antonella L.; Reis, Patricia Amelia L.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Mesquita, Amir Z.; Soares, Humberto V.

    2010-01-01

    The RELAP5 code is widely used for thermal hydraulic studies of commercial nuclear power plants. Current investigations and code adaptations have demonstrated that the RELAP5 code can be also applied for thermal hydraulic analysis of nuclear research reactors with good predictions. Therefore, as a contribution to the assessment of RELAP5/MOD3.3 for research reactors analysis, this work presents steady-state and transient calculation results performed using a RELAP5 model to simulate the IPR-R1 TRIGA research reactor at 50 kilowatts (kW) of power operation. The reactor is located in the Nuclear Technology Development Center (CDTN), Brazil. It is a 250 kW, light water moderated and cooled, graphite-reflected, open pool type research reactor. The development and the assessment of a RELAP5 model for the IPR-R1 TRIGA are presented. Experimental data were considered in the process of the RELAP5 model validation. The RELAP5 results were also compared with calculated data from the STHIRP-1 (Research Reactors Thermal Hydraulic Simulation) code. The results obtained have shown that the RELAP5 model for the IPR-R1 TRIGA reproduces the actual steady-state reactor behavior in good agreement with the available data.

  17. Simulation of a beyond design-basis-accident with RELAP5/MOD3.1

    Energy Technology Data Exchange (ETDEWEB)

    Banati, J. [Lappeenranta Univ. of Technology, Lappeenranta (Finland)

    1995-09-01

    This paper summarizes the results of analyses, parametric and sensitivity studies, performed using the RELAP5/MOD3.1 computer code for the 4th IAEA Standard Problem Exercise (SPE-4). The test, conducted on the PMK-2 facility in Budapest, involved simulation of a Small Break Loss Of Coolant Accident (SBLOCA) with a 7.4% break in the cold leg of a VVER-440 type pressurized water reactor. According to the scenario, the unavailability of the high pressure injection system led to a beyond design basis accident. For prevention of core damage, secondary side bleed-and-feed accident management measures were applied. A brief description of the PMK-2 integral type test facility is presented, together with the profile and some key phenomenological aspects of this particular experiment. Emphasis is placed on the ability of the code to predict the main trends observed in the test and thus, an assessment is given for the code capabilities to represent the system transient.

  18. RELAP5/MOD1-EUR evaluation. Comparison with the INEL original version

    International Nuclear Information System (INIS)

    Mazzantini, O.A.

    1990-01-01

    In this work, the values calculated from two versions of the RELAP5/MOD1 code are compared with those measured in different tests. The first version of RELAP5 is the cycle 19 of the original version of INEL (RELAP5/MOD1-INEL) and the second version improved by EURATOM (RELAP5/MOD1-EUR) which was transferred to ENACE through agreements made with SIEMENS/KWU. (Author) [es

  19. Assessment of RELAP5/MOD2 code using loss of offsite power transient data of KNU [Korea Nuclear Unit] No. 1 Plant

    International Nuclear Information System (INIS)

    Chung, Bud-Dong; Kim, Hho-Jung

    1990-04-01

    This report presents a code assessment study based on a real plant transient that occurred on June 9, 1981 at the KNU number-sign 1 (Korea Nuclear Unit Number 1). KNU number-sign 1 is a two-loop Westinghouse PWR plant of 587 Mwe. The loss of offsite power transient occurred at the 77.5% reactor power with 0.5%/hr power ramp. The real plant data were collected from available on-line plant records and computer diagnostics. The transient was simulated by RELAP5/MOD2/36.05 and the results were compared with the plant data to assess the code weaknesses and strengths. Some nodalization studies were performed to contribute to developing a guideline for PWR nodalization for the transient analysis. 5 refs., 18 figs., 3 tabs

  20. Assessment of a RELAP5 model for the IPR-R1 TRIGA research reactor

    International Nuclear Information System (INIS)

    Reis, Patricia A.L.; Costa, Antonella L.; Pereira, Claubia; Veloso, Maria A.F.; Mesquita, Amir Z.; Soares, Humberto V.

    2010-01-01

    RELAP5 code was developed at the Idaho National Environmental and Engineering Laboratory and it is widely used for thermal hydraulic studies of commercial nuclear power plants and, currently, it has been also applied for thermal hydraulic analysis of nuclear research systems with good predictions. This work is a contribution to the assessment of RELAP5/3.3 code for research reactors analysis. It presents steady-state and transient calculation results performed using a RELAP5 model to simulate the IPR-R1 TRIGA research reactor conditions operating at 50 and 100 kW. The reactor is located at the Nuclear Technology Development Centre (CDTN), Brazil. The development and the assessment of a RELAP5 model for the IPR-R1 TRIGA are presented. Experimental data were considered in the process of code-to-data validation. The RELAP5 results were also compared with calculation performed using the STHIRP-1 (Research Reactors Thermal Hydraulic Simulation) code. The use of a cross flow model has been essential to improve results in the transient condition respect to preceding investigations.

  1. RELAP5 analysis of PKL, main steam line break test

    Energy Technology Data Exchange (ETDEWEB)

    Jonnet, J.R.; Stempniewicz, M.M., E-mail: stempniewicz@nrg.eu; With, A. de; Wakker, P.H.

    2013-12-15

    Highlights: • RELAP5/MOD 3.2 code validation is performed by analyzing a main steam line break test in the PKL large scale test facility. • The RELAP5 model reproduces well the important events of the PKL test. • RELAP5 transient results show noticeable sensitivity to small differences in the initial conditions. • Accurate prediction of the coolant temperature is essential for the assessment of potential core re-criticality. - Abstract: PKL is a large scale test facility of the primary system owned by AREVA NP GmbH. It is used for extensive experimental investigations to study the integral behavior of Pressurized Water Reactor (PWR) plants under accident conditions. Since 2001, the test program is a part of an international cooperation project (SETH, followed by PKL1 and PKL2) set up by the OECD. The aim of the present work was to perform a short validation study of the thermo-hydraulics code RELAP5. A model of the PKL test facility has been developed, tested and applied to one of the experiments performed at the PKL. The chosen experiment was the test G3.1. In that experiment, a main steam line break occurs, causing a rapid depressurization of the affected steam generator. This leads to an increase of the heat transfer from the primary to the secondary side and thereby to a fast cool-down transient on the primary side. The main objective of this analysis was the qualification of the RELAP5 code results against heat transfer from the primary to the secondary side in both affected and intact loops, and temperatures in the primary system. The calculation results have been compared to the experimental results. It was concluded that the most important events during the test are reproduced relatively well by the model. The calculated coolant temperature in the core is higher than in the experiment. The minimum temperature is about 5% higher than measured. The secondary pressures in SG-1, 3, and 4 is in very good agreement with the experimental value, but in the

  2. Development of a model of the main turbine of the CNLV for RELAP/SCAPSIM 3.4

    International Nuclear Information System (INIS)

    Mendoza M, R.; Ortiz V, J.; Araiza M, E.

    2011-11-01

    With the objective of simulating the plant balance of the nuclear power plant of Laguna Verde (CNLV), was developed a simplified model of the turbine of high pressure and turbines of low pressure to be integrated to the model of the NSSS that is used in the code RELAP/SCDAPSIM Mod. 3.4, with the purpose of simulating the stationary state and transitory events to conditions of 2027 MWt. In the first part of this work a brief description of the main turbine of the CNLV is given. Later on, the developed model is described to be used in the mentioned code. At the end, the results of the code executions are presented as well as the comparisons against the nominal values of the CNLV in stationary state, to the indicated power. (Author)

  3. Experimental assessment of computer codes used for safety analysis of integral reactors

    Energy Technology Data Exchange (ETDEWEB)

    Falkov, A.A.; Kuul, V.S.; Samoilov, O.B. [OKB Mechanical Engineering, Nizhny Novgorod (Russian Federation)

    1995-09-01

    Peculiarities of integral reactor thermohydraulics in accidents are associated with presence of noncondensable gas in built-in pressurizer, absence of pumped ECCS, use of guard vessel for LOCAs localisation and passive RHRS through in-reactor HX`s. These features defined the main trends in experimental investigations and verification efforts for computer codes applied. The paper reviews briefly the performed experimental investigation of thermohydraulics of AST-500, VPBER600-type integral reactors. The characteristic of UROVEN/MB-3 code for LOCAs analysis in integral reactors and results of its verification are given. The assessment of RELAP5/mod3 applicability for accident analysis in integral reactor is presented.

  4. Developmental assessment of RELAP5/MOD3 using the semiscale natural circulation tests

    International Nuclear Information System (INIS)

    Carlson, K.E.

    1990-01-01

    A code development effort creating RELAP5/MOD3 from RELAP5/MOD2 has been completed. Upon completion, a developmental assessment task was performed. One of the problems used for the developmental assessment was the Semiscale Natural Circulation Test. Calculated results from RELAP5/MOD3 are compared to measured data and previously calculated results from RELAP5/MOD2. 10 refs., 6 figs., 1 tab

  5. Assessment of core damage models in SCDAP/RELAP5 during OECD LOFT LP-FP-2

    International Nuclear Information System (INIS)

    Coryell, E.W.

    1991-01-01

    The US Nuclear Regulatory Commission has sponsored a program to apply the SCDAP/RELAP5 code to analysis of the transient and reflood phases of the OECD LOFT LP-FP-2 Experiment. The principal objectives of the LP-FP-2 experiment were to determine the fission product release from the fuel during the early phases of a severe fuel damage scenario and to examine the phenomena controlling fission product transport in a vapor/aerosol environment. Calculations with the SCDAP/RELAP5 code, developed at the INEL with NRC support, have been performed to (1) examine the phenomena controlling the progression of both transient and reflood phases of the experiment, (2) enhance our understanding of the phenomena occurring during reflood and add credence to the postulated phenomenological sequence, (3) assess the ability of SCDAP/RELAP5 to examine severe fuel damage issues and phenomena, and (4) identify code strengths and deficiencies with the intent of prioritizing code improvements. Results indicate that the code is able to analyze the early phases of severe fuel damage reasonably well, with potential deficiencies in modelling interaction between molten control rod material and intact fuel

  6. How good are thermal-hydraulics codes for analyses of plant transients

    International Nuclear Information System (INIS)

    Fabic, S.

    1996-01-01

    In the early seventies, all thermal-hydraulics codes were based on the Homogeneous Equilibrium Model (HEM), represented by three conservation equations: mixture mass, momentum and energy. Various means were utilized to solve the resulting system of equations: finite differences in FLASH, SATAN, RELAP3 and RELAP4, method of characteristics in BLOWDWN2, loop momentum method in RAMONA and NORCOOL, and others. As the result the world came to regard HEM as too restrictive and the Two-Fluid model came into fashion, first featuring a six and later, a seven-equation model. New codes like KACHINA, TRAC and RELAP5 were developed also. Experience and comparisons with test data have recently forced us to wonder whether the ability to 'compute' while considering great many complexities, ran ahead of the ability to competently define various interactions between fluid phases and components that such complex codes require. The long running times are also a problem that needs to be resolved. More recent trends in the treatment of thermal-hydraulics in Power Plant Simulators and in Plant Analyzers will also be discussed

  7. IEA-R1 reactor core simulation with RELAP5 code

    International Nuclear Information System (INIS)

    Rocha, Ricardo Takeshi Vieira da; Belchior Junior, Antonio; Andrade, Delvonei Alves de; Sabundjian, Gaiane; Umbehaum, Pedro Ernesto; Torres, Walmir Maximo

    2005-01-01

    This paper presents a preliminary RELAP5 model for the IEA-R1 core. The power distribution is supplied by the neutronic code, CITATION. The main objective is to model the IEA-R1 core and validate the model through the comparison of the results to the ones from COBRA and PARET, which were used in the Final Safety Analysis Report (FSAR) for this plant. Preliminary calculations regarding some simulations are presented. Boundary conditions are simulated through time dependent components. Results obtained are compared to those available for the IEA-R1. This study will be continued considering a model for the whole plant. Important transient and accidents will be analysed in order to verify the Emergency Core Cooling System - ECCS efficiency to hold its function as projected to preserve the integrity of the reactor core and guarantee its cooling. (author)

  8. Latest improvements on TRACPWR six-equations thermohydraulic code

    International Nuclear Information System (INIS)

    Rivero, N.; Batuecas, T.; Martinez, R.; Munoz, J.; Lenhardt, G.; Serrano, P.

    1999-01-01

    The paper presents the latest improvements on TRACPWR aimed at adapting the code to present trends on computer platforms, architectures and training requirements as well as extending the scope of the code itself and its applicability to other technologies different from Westinghouse PWR one. Firstly major features of TRACPWR as best estimate and real time simulation code are summed, then the areas where TRACPWR is being improved are presented. These areas comprising: (1) Architecture: integrating TRACPWR and RELAP5 codes, (2) Code scope enhancement: modelling the Mid-Loop operation, (3) Code speed-up: applying parallelization techniques, (4) Code platform downswing: porting to Windows N1 platform, (5) On-line performance: allowing simulation initialisation from a Plant Process Computer, and (6) Code scope extension: using the code for modelling VVER and PHWR technology. (author)

  9. Extensions to the SCDAP/RELAP5 code for the modeling of debris oxidation and materials interactions preliminary design report

    International Nuclear Information System (INIS)

    Siefken, L.J.; Davis, K.L.

    1993-02-01

    Preliminary designs are proposed for extending the SCDAP/RELAP5 code so that it models (a) the oxidation of slumping fuel rod material and cohesive and porous debris and (b) the interaction of PWR control rod materials with the other materials in a reactor core. These extensions have the purpose of improving the code's calculation of the damage progression and hydrogen production that takes place during the early phase of a severe accident

  10. MARS code manual volume I: code structure, system models, and solution methods

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Kim, Kyung Doo; Bae, Sung Won; Jeong, Jae Jun; Lee, Seung Wook; Hwang, Moon Kyu; Yoon, Churl

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This theory manual provides a complete list of overall information of code structure and major function of MARS including code architecture, hydrodynamic model, heat structure, trip / control system and point reactor kinetics model. Therefore, this report would be very useful for the code users. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  11. Nuclear Plant Analyzer: an interactive TRAC/RELAP Power-Plant Simulation Program

    International Nuclear Information System (INIS)

    Steinke, R.; Booker, C.; Giguere, P.; Liles, D.; Mahaffy, J.; Turner, M.; Wiley, R.

    1984-01-01

    The Nuclear Plant Analyzer (NPA) is a computer-software interface for executing the TRAC or RELAP5 power-plant systems codes. The NPA is designed to use advanced supercomputers, long-distance data communications, and a remote workstation terminal with interactive computer graphics to analyze power-plant thermal-hydraulic behavior. The NPA interface simplifies the running of these codes through automated procedures and dialog interaction. User understanding of simulated-plant behavior is enhanced through graphics displays of calculational results. These results are displayed concurrently with the calculation. The user has the capability to override the plant's modeled control system with hardware adjustment commands. This gives the NPA the utility of a simulator, and at the same time, the accuracy of an advanced, best-estimate, power-plant systems code for plant operation and safety analysis

  12. Development of Multi-Dimensional RELAP5 with Conservative Momentum Flux

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hyung Wook; Lee, Sang Yong [KINGS, Ulsan (Korea, Republic of)

    2016-10-15

    The non-conservative form of the momentum equations are used in many codes. It tells us that using the non-conservative form in the non-porous or open body problem may not be good. In this paper, two aspects concerning the multi-dimensional codes will be discussed. Once the validity of the modified code is confirmed, it is applied to the analysis of the large break LOCA for APR-1400. One of them is the properness of the type of the momentum equations. The other discussion will be the implementation of the conservative momentum flux term in RELAP5. From the present study and former, it is shown that the RELAP5 Multi-D with conservative convective terms is applicable to LOCA analysis. And the implementation of the conservative convective terms in RELAP5 seems to be successful. Further efforts have to be made on making it more robust.

  13. Development of an integrated thermal-hydraulics capability incorporating RELAP5 and PANTHER neutronics code

    Energy Technology Data Exchange (ETDEWEB)

    Page, R.; Jones, J.R.

    1997-07-01

    Ensuring that safety analysis needs are met in the future is likely to lead to the development of new codes and the further development of existing codes. It is therefore advantageous to define standards for data interfaces and to develop software interfacing techniques which can readily accommodate changes when they are made. Defining interface standards is beneficial but is necessarily restricted in application if future requirements are not known in detail. Code interfacing methods are of particular relevance with the move towards automatic grid frequency response operation where the integration of plant dynamic, core follow and fault study calculation tools is considered advantageous. This paper describes the background and features of a new code TALINK (Transient Analysis code LINKage program) used to provide a flexible interface to link the RELAP5 thermal hydraulics code with the PANTHER neutron kinetics and the SIBDYM whole plant dynamic modelling codes used by Nuclear Electric. The complete package enables the codes to be executed in parallel and provides an integrated whole plant thermal-hydraulics and neutron kinetics model. In addition the paper discusses the capabilities and pedigree of the component codes used to form the integrated transient analysis package and the details of the calculation of a postulated Sizewell `B` Loss of offsite power fault transient.

  14. Development of an integrated thermal-hydraulics capability incorporating RELAP5 and PANTHER neutronics code

    International Nuclear Information System (INIS)

    Page, R.; Jones, J.R.

    1997-01-01

    Ensuring that safety analysis needs are met in the future is likely to lead to the development of new codes and the further development of existing codes. It is therefore advantageous to define standards for data interfaces and to develop software interfacing techniques which can readily accommodate changes when they are made. Defining interface standards is beneficial but is necessarily restricted in application if future requirements are not known in detail. Code interfacing methods are of particular relevance with the move towards automatic grid frequency response operation where the integration of plant dynamic, core follow and fault study calculation tools is considered advantageous. This paper describes the background and features of a new code TALINK (Transient Analysis code LINKage program) used to provide a flexible interface to link the RELAP5 thermal hydraulics code with the PANTHER neutron kinetics and the SIBDYM whole plant dynamic modelling codes used by Nuclear Electric. The complete package enables the codes to be executed in parallel and provides an integrated whole plant thermal-hydraulics and neutron kinetics model. In addition the paper discusses the capabilities and pedigree of the component codes used to form the integrated transient analysis package and the details of the calculation of a postulated Sizewell 'B' Loss of offsite power fault transient

  15. Comparison of ATHENA/RELAP results against ice experimental data

    CERN Document Server

    Moore-Richard, L

    2002-01-01

    In order to demonstrate the adequacy of the International Thermonuclear Experimental Reactor design from a safety stand point as well as investigating the behavior of two-phase flow phenomena during an ingress of coolant event, an integrated ICE test facility was constructed in Japan. The data generated from the ICE facility offers a valuable means to validate computer codes such as ATHENA /RELAP5, which is one of the codes used at the Idaho National Engineering And Environmental Laboratory (INEEL) to evaluate the safety of various fusion reactor concepts. In this paper we compared numerical results generated by the ATHENA code with corresponding test data from the ICE facility. Overall we found good agreement between the test data and the predicted results.

  16. SCDAP/RELAP5 modeling of fluid heat transfer and flow losses through porous debris in a light water reactor

    International Nuclear Information System (INIS)

    Harvego, E. A.; Siefken, L. J.

    2000-01-01

    The SCDAP/RELAP5 code is being developed at the Idaho National Engineering and Environmental Laboratory under the primary sponsorship of the U.S. Nuclear Regulatory Commission (NRC) to provide best-estimate transient simulations of light water reactor coolant systems during severe accidents. This paper describes the modeling approach used in the SCDAP/RELAP5 code to calculate fluid heat transfer and flow losses through porous debris that has accumulated in the vessel lower head and core regions during the latter stages of a severe accident. The implementation of heat transfer and flow loss correlations into the code is discussed, and calculations performed to assess the validity of the modeling approach are described. The different modes of heat transfer in porous debris include: (1) forced convection to liquid, (2) forced convection to gas, (3) nucleate boiling, (4) transition boiling, (5) film boiling, and (6) transition from film boiling to convection to vapor. The correlations for flow losses in porous debris include frictional and form losses. The correlations for flow losses were integrated into the momentum equations in the RELAP5 part of the code. Since RELAP5 is a very general non-homogeneous non-equilibrium thermal-hydraulics code, the resulting modeling methodology is applicable to a wide range of debris thermal-hydraulic conditions. Assessment of the SCDAP/RELAP5 debris bed thermal-hydraulic models included comparisons with experimental measurements and other models available in the open literature. The assessment calculations, described in the paper, showed that SCDAP/RELAP5 is capable of calculating the heat transfer and flow losses occurring in porous debris regions that may develop in a light water reactor during a severe accident

  17. Initial Coupling of the RELAP-7 and PRONGHORN Applications

    Energy Technology Data Exchange (ETDEWEB)

    J. Ortensi; D. Andrs; A.A. Bingham; R.C. Martineau; J.W. Peterson

    2012-10-01

    Modern nuclear reactor safety codes require the ability to solve detailed coupled neutronic- thermal fluids problems. For larger cores, this implies fully coupled higher dimensionality spatial dynamics with appropriate feedback models that can provide enough resolution to accurately compute core heat generation and removal during steady and unsteady conditions. The reactor analysis code PRONGHORN is being coupled to RELAP-7 as a first step to extend RELAP’s current capabilities. This report details the mathematical models, the type of coupling, and the testing results from the integrated system. RELAP-7 is a MOOSE-based application that solves the continuity, momentum, and energy equations in 1-D for a compressible fluid. The pipe and joint capabilities enable it to model parts of the power conversion unit. The PRONGHORN application, also developed on the MOOSE infrastructure, solves the coupled equations that define the neutron diffusion, fluid flow, and heat transfer in a full core model. The two systems are loosely coupled to simplify the transition towards a more complex infrastructure. The integration is tested on a simplified version of the OECD/NEA MHTGR-350 Coupled Neutronics-Thermal Fluids benchmark model.

  18. RELAP5/MOD2 implementation on various mainframes including the IBM and SX-2 supercomputer

    International Nuclear Information System (INIS)

    DeForest, D.L.; Hassan, Y.A.

    1987-01-01

    The RELAP5/MOD2 (cycle 36.04) code is a one-dimensional, two-fluid, nonequilibrium, nonhomogeneous transient analysis code designed to simulate operational and accident scenarios in pressurized water reactors (PWRs). System models are solved using a semi-implicit finite difference method. The code was developed at EG and G in Idaho Falls under sponsorship of the US Nuclear Regulatory Commission (NRC). The major enhancement from RELAP5/MOD1 is the use of a six-equation, two-fluid nonequilibrium and nonhomogeneous model. Other improvements include the addition of a noncondensible gas component and the revision and addition of drag formulation, wall friction, and wall heat transfer. Several test cases were run to benchmark the IBM and SX-2 installations against the CDC computer and the CRAY-2 and CRAY/XMP. These included the Edward's pipe blow-down and two separate reflood cases developed to simulate the FLECHT-SEASET reflood test 31504 and a postcritical heat flux (CHF) test performed at Lehigh University

  19. RELAP5 / MOD3.2 analysis of INSC standard problem INSCSP - V4 : investigation of heat transfer for partly uncovered VVER-1000 core at the test facility KS (RRC K1)

    International Nuclear Information System (INIS)

    Tentner, A.; Ahrens, J. W.

    2002-01-01

    The RELAP5/MOD3.2 computer program has been used to analyze a series of tests investigating heat-transfer from a partly uncovered VVER-1000 core in the KS test facility at the Russian Research Center ''Kurchatov Institute'' (RRC-KI). The analysis documented represents VVER Standard Problem 4 in Joint Project 6, which is the investigation of Computer Code Validation for Transient Analysis of RBMK and VVER Reactors, between the United States and Russian International Nuclear Safety Centers. The experiment facility and data, RELAP5 nodalization, and results are shown for one of the six tests defined in Standard Problem 4. Only part of the data was analyzed due to our conclusion that the available experimental data is not sufficient to allow the modeling of the actual experiment sequence. The experiment initial conditions were reached through a series of transient processes, about which no quantitative information was available. This has required the modeling of an arbitrary computational transient, with the goal of reaching initial conditions similar to those observed during the experiment. The use of an arbitrary transient introduces many degrees of freedom in the analysis, i.e. initial computational values that influence the entire sequence of events, including the loop behavior during the experiment time window. Reasonable agreement between RELAP5 and the experiment data can be obtained by manipulating a number of initial computational values, including the liquid level in the fuel assembly model, the liquid level in the annular region, the quality of the saturated vapor in the voided loop regions, etc. Our study has focused on exploring the sensitivity of results to changes in these initial values which are not based on experimental information, but are selected with the goal of matching the experimentally observed behavior during the experiment time window. We have shown that changes in several initial arbitrary values can lead to similar changes in the

  20. RELAP5 based engineering simulator

    International Nuclear Information System (INIS)

    Charlton, T.R.; Laats, E.T.; Burtt, J.D.

    1990-01-01

    The INEL Engineering Simulation Center was established in 1988 to provide a modern, flexible, state-of-the-art simulation facility. This facility and two of the major projects which are part of the simulation center, the Advance Test Reactor (ATR) engineering simulator project and the Experimental Breeder Reactor (EBR-II) advanced reactor control system, have been the subject of several papers in the past few years. Two components of the ATR engineering simulator project, RELAP5 and the Nuclear Plant Analyzer (NPA), have recently been improved significantly. This paper presents an overview of the INEL Engineering Simulation Center, and discusses the RELAP5/MOD3 and NPA/MOD1 codes, specifically how they are being used at the INEL Engineering Simulation Center. It provides an update on the modifications to these two codes and their application to the ATR engineering simulator project, as well as, a discussion on the reactor system representation, control system modeling, two phase flow and heat transfer modeling. It will also discuss how these two codes are providing desktop, stand-alone reactor simulation

  1. SCDAP/RELAP5 lower core plate model

    International Nuclear Information System (INIS)

    Coryell, E.W.; Griffin, F.P.

    1999-01-01

    The SCDAP/RELAP5 computer code is a best-estimate analysis tool for performing nuclear reactor severe accident simulations. This report describes the justification, theory, implementation, and testing of a new modeling capability which will refine the analysis of the movement of molten material from the core region to the vessel lower head. As molten material moves from the core region through the core support structures it may encounter conditions which will cause it to freeze in the region of the lower core plate, delaying its arrival to the vessel head. The timing of this arrival is significant to reactor safety, because during the time span for material relocation to the lower head, the core may be experiencing steam-limited oxidation. The time at which hot material arrives in a coolant-filled lower vessel head, thereby significantly increasing the steam flow rate through the core region, becomes significant to the progression and timing of a severe accident. This report is a revision of a report INEEL/EXT-00707, entitled ''Preliminary Design Report for SCDAP/RELAP5 Lower Core Plate Model''

  2. Estimate of LOCA-FI plenum pressure uncertainty for a five-ring RELAP5 production reactor model

    International Nuclear Information System (INIS)

    Griggs, D.P.

    1993-03-01

    The RELAP5/MOD2.5 code (RELAP5) is used to perform best-estimate analyses of certain postulated Design Basis Accidents (DBAs) in SRS production reactors. Currently, the most limiting DBA in terms of reactor power level is an instantaneous double-ended guillotine break (DEGB) loss of coolant accident (LOCA). A six-loop RELAP5 K Reactor model is used to analyze the reactor system behavior dozing the Flow Instability (FI) phase of the LOCA, which comprises only the first 5 seconds following the DEGB. The RELAP5 K Reactor model includes tank and plenum nodalizations having five radial rings and six azimuthal sectors. The reactor system analysis provides time-dependent plenum and tank bottom pressures for use as boundary conditions in the FLOWTRAN code, which models a single fuel assembly in detail. RELAP5 also performs the system analysis for the latter phase of the LOCA, denoted the Emergency Cooling System (ECS) phase. Results from the RELAP analysis are used to provide boundary conditions to the FLOWTRAN-TF code, which is an advanced two-phase version of FLOWTRAN. The RELAP5 K Reactor model has been tested for LOCA-FI and Loss-of-Pumping Accident analyses and the results compared with equivalent analyses performed with the TRAC-PF1/MOD1 code (TRAC). An equivalent RELAP5 six-loop, five-ring, six-sector L Reactor model has been benchmarked against qualified single-phase system data from the 1989 L-Area In-Reactor Test Program. The RELAP5 K and L Reactor models have also been subjected to an independent Quality Assurance verification

  3. RELAPS choked flow model and application to a large scale flow test

    International Nuclear Information System (INIS)

    Ransom, V.H.; Trapp, J.A.

    1980-01-01

    The RELAP5 code was used to simulate a large scale choked flow test. The fluid system used in the test was modeled in RELAP5 using a uniform, but coarse, nodalization. The choked mass discharge rate was calculated using the RELAP5 choked flow model. The calulations were in good agreement with the test data, and the flow was calculated to be near thermal equilibrium

  4. Analysis of the IRIS pressurizer behavior in the presence of noncondensable gases using RELAP5 computer code

    International Nuclear Information System (INIS)

    Medeiros, Eduarda da C.A.; Castrillo, Lazara S.

    2015-01-01

    Insurge and outsurge phenomena are transient states and could be analyzed by thermodynamics principles, the pressurizer behavior will vary in response to mass flow changes. These surges can occur in the presence of noncondensable gases. On this paper, with the code RELAP5, the IRIS reactor pressurizer is described to analyze surges phenomena in their control volumes with non-condensable gases since they modify the pressure response. A set of three pipes components represents the pressurizer regions, connected with each other by single junctions components, the bottom volume control is connected to the primary circuit, represented by a time dependent volume component, through a time dependent junction component, which describes the mass flow behavior during surges through surge orifices. The hydrodynamic components representing the pressurizer are surrounded by heat structures, in addition there are heat structures inside the bottom volume control describing the behavior of electrical heaters, that operate in cases of outsurges. The analysis are intended to detail the behavior variables as pressure, temperature and volume of liquid inside the pressurizer during a water surge coming from the primary circuit or a water surge coming from the pressurizer to the primary circuit. (author)

  5. Analysis of the IRIS pressurizer behavior in the presence of noncondensable gases using RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, Eduarda da C.A.; Castrillo, Lazara S., E-mail: e.camedeiros@gmail.com, E-mail: lazara@poli.br [Universidade de Pernambuco, Recife, PE (Brazil). Escola Politecnica. Departamento de Engenharia Mecanica

    2015-07-01

    Insurge and outsurge phenomena are transient states and could be analyzed by thermodynamics principles, the pressurizer behavior will vary in response to mass flow changes. These surges can occur in the presence of noncondensable gases. On this paper, with the code RELAP5, the IRIS reactor pressurizer is described to analyze surges phenomena in their control volumes with non-condensable gases since they modify the pressure response. A set of three pipes components represents the pressurizer regions, connected with each other by single junctions components, the bottom volume control is connected to the primary circuit, represented by a time dependent volume component, through a time dependent junction component, which describes the mass flow behavior during surges through surge orifices. The hydrodynamic components representing the pressurizer are surrounded by heat structures, in addition there are heat structures inside the bottom volume control describing the behavior of electrical heaters, that operate in cases of outsurges. The analysis are intended to detail the behavior variables as pressure, temperature and volume of liquid inside the pressurizer during a water surge coming from the primary circuit or a water surge coming from the pressurizer to the primary circuit. (author)

  6. The RELAP5-Based NPA of the VVER Type Paks NPP

    International Nuclear Information System (INIS)

    Guba, A.; Toth, I.; Mandy, C.; Stubbe, E.

    1999-01-01

    NPA is a data driven interactive graphical tool for visualisation of different plant conditions. Data generated by the analysis code RELAP5/MOD3.2 are processed and displayed on a computer monitor. The NPA model of Paks NPP Unit 3 was developed with the aim to demonstrate the phenomena occurring in different transient/accident scenarios. This VVER-specific NPA development is a result of a cooperation between BELGATOM and KFKI-AEKI. (author)

  7. Brayton Cycle Numerical Modeling using the RELAP5-3D code, version 4.3.4

    Energy Technology Data Exchange (ETDEWEB)

    Longhini, Eduardo P.; Lobo, Paulo D.C.; Guimarães, Lamartine N.F.; Filho, Francisco A.B.; Ribeiro, Guilherme B., E-mail: edu_longhini@yahoo.com.br [Instituto de Estudos Avançados (IEAv), São José dos Campos, SP (Brazil). Divisão de Energia Nuclear

    2017-07-01

    This work contributes to enable and develop technologies to mount fast micro reactors, to generate heat and electric energy, for the purpose to warm and to supply electrically spacecraft equipment and, also, the production of nuclear space propulsion effect. So, for this purpose, the Brayton Cycle demonstrates to be an optimum approach for space nuclear power. The Brayton thermal cycle gas has as characteristic to be a closed cycle, with two adiabatic processes and two isobaric processes. The components performing the cycle's processes are compressor, turbine, heat source, cold source and recuperator. Therefore, the working fluid's mass flow runs the thermal cycle that converts thermal energy into electrical energy, able to use in spaces and land devices. The objective is numerically to model the Brayton thermal cycle gas on nominal operation with one turbomachine composed for a radial-inflow compressor and turbine of a 40.8 kWe Brayton Rotating Unit (BRU). The Brayton cycle numerical modeling is being performed with the program RELAP5-3D, version 4.3.4. The nominal operation uses as working fluid a mixture 40 g/mole He-Xe with a flow rate of 1.85 kg/s, shaft rotational speed of 45 krpm, compressor and turbine inlet temperature of 400 K and 1149 K, respectively, and compressor exit pressure 0.931 MPa. Then, the aim is to get physical corresponding data to operate each cycle component and the general cycle on this nominal operation. (author)

  8. Brayton Cycle Numerical Modeling using the RELAP5-3D code, version 4.3.4

    International Nuclear Information System (INIS)

    Longhini, Eduardo P.; Lobo, Paulo D.C.; Guimarães, Lamartine N.F.; Filho, Francisco A.B.; Ribeiro, Guilherme B.

    2017-01-01

    This work contributes to enable and develop technologies to mount fast micro reactors, to generate heat and electric energy, for the purpose to warm and to supply electrically spacecraft equipment and, also, the production of nuclear space propulsion effect. So, for this purpose, the Brayton Cycle demonstrates to be an optimum approach for space nuclear power. The Brayton thermal cycle gas has as characteristic to be a closed cycle, with two adiabatic processes and two isobaric processes. The components performing the cycle's processes are compressor, turbine, heat source, cold source and recuperator. Therefore, the working fluid's mass flow runs the thermal cycle that converts thermal energy into electrical energy, able to use in spaces and land devices. The objective is numerically to model the Brayton thermal cycle gas on nominal operation with one turbomachine composed for a radial-inflow compressor and turbine of a 40.8 kWe Brayton Rotating Unit (BRU). The Brayton cycle numerical modeling is being performed with the program RELAP5-3D, version 4.3.4. The nominal operation uses as working fluid a mixture 40 g/mole He-Xe with a flow rate of 1.85 kg/s, shaft rotational speed of 45 krpm, compressor and turbine inlet temperature of 400 K and 1149 K, respectively, and compressor exit pressure 0.931 MPa. Then, the aim is to get physical corresponding data to operate each cycle component and the general cycle on this nominal operation. (author)

  9. SCDAP/RELAP5/MOD 3.1 code manual: Damage progression model theory. Volume 2

    International Nuclear Information System (INIS)

    Davis, K.L.

    1995-06-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, the core, fission products released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume contains detailed descriptions of the severe accident models and correlations. It provides the user with the underlying assumptions and simplifications used to generate and implement the basic equations into the code, so an intelligent assessment of the applicability and accuracy of the resulting calculation can be made

  10. SCDAP/RELAP5/MOD 3.1 code manual: Damage progression model theory. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Davis, K.L. [ed.; Allison, C.M.; Berna, G.A. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)] [and others

    1995-06-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, the core, fission products released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume contains detailed descriptions of the severe accident models and correlations. It provides the user with the underlying assumptions and simplifications used to generate and implement the basic equations into the code, so an intelligent assessment of the applicability and accuracy of the resulting calculation can be made.

  11. Thermal-hydraulic calculations for a fuel assembly in a European Pressurized Reactor using the RELAP5 code

    Directory of Open Access Journals (Sweden)

    Skrzypek Maciej

    2015-09-01

    Full Text Available The main object of interest was a typical fuel assembly, which constitutes a core of the nuclear reactor. The aim of the paper is to describe the phenomena and calculate thermal-hydraulic characteristic parameters in the fuel assembly for a European Pressurized Reactor (EPR. To perform thermal-hydraulic calculations, the RELAP5 code was used. This code allows to simulate steady and transient states for reactor applications. It is also an appropriate calculation tool in the event of a loss-of-coolant accident in light water reactors. The fuel assembly model with nodalization in the RELAP5 (Reactor Excursion and Leak Analysis Program code was presented. The calculations of two steady states for the fuel assembly were performed: the nominal steady-state conditions and the coolant flow rate decreased to 60% of the nominal EPR flow rate. The calculation for one transient state for a linearly decreasing flow rate of coolant was simulated until a new level was stabilized and SCRAM occurred. To check the correctness of the obtained results, the authors compared them against the reactor technical documentation available in the bibliography. The obtained results concerning steady states nearly match the design data. The hypothetical transient showed the importance of the need for correct cooling in the reactor during occurrences exceeding normal operation. The performed analysis indicated consequences of the coolant flow rate limitations during the reactor operation.

  12. Adjoint sensitivity analysis of the RELAPS/MOD3.2 two-fluid thermal-hydraulic code system

    International Nuclear Information System (INIS)

    Ionescu-Bujor, M.

    2000-10-01

    This work presents the implementation of the Adjoint Sensitivity Analysis Procedure (ASAP) for the non-equilibrium, non-homogeneous two-fluid model, including boron concentration and non-condensable gases, of the RELAP5/MOD3.2 code. The end-product of this implementation is the Adjoint Sensitivity Model (ASM-REL/TF), which is derived for both the differential and discretized equations underlying the two-fluid model with non-condensable(s). The consistency requirements between these two representations are also highlighted. The validation of the ASM-REL/TF has been carried out by using sample problems involving: (i) liquid-phase only, (ii) gas-phase only, and (iii) two-phase mixture (of water and steam). Thus the 'Two-Loops with Pumps' sample problem supplied with RELAP5/MOD3.2 has been used to verify the accuracy and stability of the numerical solution of the ASM-REL/TF when only the liquid-phase is present. Furthermore, the 'Edwards Pipe' sample problem, also supplied with RELAP5/MOD3.2, has been used to verify the accuracy and stability of the numerical solution of the ASM-REL/TF when both (i.e., liquid and gas) phases are present. In addition, the accuracy and stability of the numerical solution of the ASM-REL/TF have been verified when only the gas-phase is present by using modified 'Two-Loops with Pumps' and the 'Edwards Pipe' sample problems in which the liquid and two-phase fluids, respectively, were replaced by pure steam. The results obtained for these sample problems depict typical sensitivities of junction velocities and volume-averaged pressures to perturbations in initial conditions, and indicate that the numerical solution of the ASM-REL/TF is as robust, stable, and accurate as the original RELAP5/MOD3.2 calculations. In addition, the solution of the ASM-REL/TF has been used to calculate sample sensitivities of volume-averaged pressures to variations in the pump head. (orig.) [de

  13. PHISICS multi-group transport neutronic capabilities for RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Epiney, A.; Rabiti, C.; Alfonsi, A.; Wang, Y.; Cogliati, J.; Strydom, G. [Idaho National Laboratory (INL), 2525 N. Fremont Ave., Idaho Falls, ID 83402 (United States)

    2012-07-01

    PHISICS is a neutronic code system currently under development at INL. Its goal is to provide state of the art simulation capability to reactor designers. This paper reports on the effort of coupling this package to the thermal hydraulic system code RELAP5. This will enable full prismatic core and system modeling and the possibility to model coupled (thermal-hydraulics and neutronics) problems with more options for 3D neutron kinetics, compared to the existing diffusion theory neutron kinetics module in RELAP5 (NESTLE). The paper describes the capabilities of the coupling and illustrates them with a set of sample problems. (authors)

  14. SCDAP/RELAP5/MOD 3.1 code manual: User's guide and input manual. Volume 3

    International Nuclear Information System (INIS)

    Coryell, E.W.; Johnsen, E.C.; Allison, C.M.

    1995-06-01

    The SCDAP/RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during a severe accident. The code models the coupled behavior of the reactor coolant system, core, fission product released during a severe accident transient as well as large and small break loss of coolant accidents, operational transients such as anticipated transient without SCRAM, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits as much of a particular system to be modeled as necessary. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater conditioning systems. This volume provides guidelines to code users based upon lessons learned during the developmental assessment process. A description of problem control and the installation process is included. Appendix a contains the description of the input requirements

  15. Application of the Relap5-3D to phase 1 and 3 of the OECD-CSNI/NSC PWR MSLB benchmark related to TMI-1

    International Nuclear Information System (INIS)

    D'Auria, F.; Galassi, G.; Spadoni, A.; Hassan, Y.

    2001-01-01

    The Relap5-3D, the latest in the series of the Relap5 code, distinguishes from the previous versions by the fully integrated, multi-dimensional thermalhydraulic and kinetic modeling capability. It has been applied to Phase I and III of OECD-CSNI/ NSC PWR MSLB Benchmark adopting the same thermalhydraulic input deck already used with Relap5/Parcs and Relap5/Quabbox coupled codes during the previous MSLB analysis. The OECD jointly with the US NRC proposed the PWR MSLB Benchmark in order to gather a common understanding about the coupling between thermal hydraulics and neutronics, and evaluating the behavior of this transient with different coupled codes, giving emphasis to the 3-D modeling. This paper deals with the application of Relap5-3D code to phase I and III of the PWR MSLB Benchmark. The Relap5-3D is a thermal hydraulics-neutronics internally coupled code, the thermal hydraulics module is the INEEL version of Relap and the neutronics module is derived from NESTLE multi-dimension kinetics code. (author)

  16. Development of a computer code for thermohydraulic analysis of a heated channel in transients

    International Nuclear Information System (INIS)

    Jafari, J.; Kazeminejad, H.; Davilu, H.

    2004-01-01

    This paper discusses the thermohydraulic analysis of a heated channel of a nuclear reactor in transients by a computer code that has been developed by the writer. The considered geometry is a channel of a nuclear reactor with cylindrical or planar fuel rods. The coolant is water and flows from the outer surface of the fuel rod. To model the heat transfer in the fuel rod, two dimensional time dependent conduction equations has been solved by combination of numerical methods, O rthogonal Collocation Method in radial direction and finite difference method in axial direction . For coolant modelling the single phase time dependent energy equation has been used and solved by finite difference method . The combination of the first module that solves the conduction in the fuel rod and a second one that solved the energy balance in the coolant region constitute the computer code (Thyc-1) to analysis thermohydraulic of a heated channel in transients. The Orthogonal collocation method maintains the accuracy and computing time of conventional finite difference methods, while the computer storage is reduced by a factor of two. The same problem has been modelled by RELAP5/M3 system code to asses the validity of the Thyc-1 code. The good agreement of the results qualifies the developed code

  17. The COSIMA-experiments, a data base for validation of two-phase flow computer codes

    International Nuclear Information System (INIS)

    Class, G.; Meyder, R.; Stratmanns, E.

    1985-12-01

    The report presents an overview on the large data base generated with COSIMA. The data base is to be used to validate and develop computer codes for two-phase flow. In terms of fuel rod behavior it was found that during blowdown under realistic conditions only small strains are reached. For clad rupture extremely high rod internal pressure is necessary. Additionally important results were found in the behavior of a fuel rod simulator and on the effect of thermocouples attached on the cladding outer surface. Post-test calculations, performed with the codes RELAP and DRUFAN show a good agreement with the experiments. This however can be improved if the phase separation models in the codes would be updated. (orig./HP) [de

  18. Standard model of WWER-440 fuel rod for Transuranus and its application for RELAP5 hot channel validation

    International Nuclear Information System (INIS)

    Hatala, B.; Cvan, M.

    2001-01-01

    Within the PECO European Commission project of 'Extension of the validation matrix of the TRANSURANUS code' is developed a generic model of WWER-440 fuel rod. The model is intended to be applied for both realistic and licensing, conservative analysis. For such an application the TRANSURANUS code would be complementary tool to generally used system codes, e.g. RELAP5, providing realistic, more detailed insight into processes and safety criteria, relevant to the fuel rod. The paper presents general description of the model for TRANSURANUS code, brief discussion of approaches used in TRANSURANUS and RELAP5 code safety analysis, accompanied with information about RELAP5 model (whole scope unit model, used for licensing analysis). The existing model for RELAP5 code for WWER-440/V-213 Bohunice V2 unit is checked and modified in hot channel part to allow transparent comparison with the TRANSURANUS code. The results from comparison calculations of the both codes are presented for fresh fuel and quasi steady state scenario and are in good agreement, almost identical. These results might be used as a basis for transient analysis

  19. RELAP5 based engineering simulator

    International Nuclear Information System (INIS)

    Charlton, T.R.; Laats, E.T.; Burtt, J.D.

    1990-01-01

    The INEL Engineering Simulation Center was established in 1988 to provide a modern, flexible, state-of-the-art simulation facility. This facility and two of the major projects which are part of the simulation center, the Advance Test Reactor (ATR) engineering simulator project and the Experimental Breeder Reactor II (EBR-II) advanced reactor control system, have been the subject of several papers in the past few years. Two components of the ATR engineering simulator project, RELAP5 and the Nuclear Plant Analyzer (NPA), have recently been improved significantly. This paper will present an overview of the INEL Engineering Simulation Center, and discuss the RELAP5/MOD3 and NPA/MOD1 codes, specifically how they are being used at the INEL Engineering Simulation Center. It will provide an update on the modifications to these two codes and their application to the ATR engineering simulator project, as well as, a discussion on the reactor system representation, control system modeling, two phase flow and heat transfer modeling. It will also discuss how these two codes are providing desktop, stand-alone reactor simulation. 12 refs., 2 figs

  20. Feasibility study of the vectorization of nuclear codes used at the ENEL Thermal and Nuclear Research Centre

    International Nuclear Information System (INIS)

    Di Pasquantonio, F.

    1987-01-01

    The purpose of this report is that of analyzing tha problems connected with the vectorization and/or multitasking of several computer codes utilized in the ENEL-DSR Centro Ricerca Termica e Nucleare. After some general remarks on vector computers the analysis is focused on some topic relating to vectorization and multitasking of programs written for scalar computers. The priority for vectorization and/or multitasking has been given at the following codes: 1) DOT 4.2 (radiation transport and shielding); 2) QUANDRY (accidental and operating transients in LWR cores); 3) MORSE and MCNP (Monte Carlo codes for radiation transport and shielding); 4) RELAP (accidental and operating transients in LWR plants); 5) TRAP-MELT and NAUA (evaluation of source term). The principal results of the study are the following: 1) For the DOT 4.2 code it is convenients to improve the vectorized version DOT IV/C developed by Swanson introducing the parallel S.O.R. iterative method; 2) For the code QUANDRY it is proposed to introduce the three dimensional red-black mesh point ordering named ''diagonal method''; 3) To implements, on the CRAY X/MP 48, the multitasked version of the code MCNP developed by the Los Alamos National Lboratory; 4) To implements, on the CRAY X/MP 12, the vectorized and optimized version of the codes RELAP5/MOD1-MOD2 developed by J.R.C. EUROATOM-Ispra; 5) For the codes TRAP-MELT and NAUA the insertion of the vectorized routines LSODP na LSODPK for dominanting stiff cases

  1. RELAP5 analysis of PACTEL injection tests

    International Nuclear Information System (INIS)

    Kimber, G.R.; Lillington, J.N.

    2000-01-01

    A characteristic feature of advanced reactor designs is their reliance on passive safety systems. It is important to assess both the operation of such systems and the ability of systems codes, such as RELAP5, to model them. In Finland VTT Energy, together with Lappeenranta University of Technology, is using the PACTEL facility for the investigation of passive core cooling systems. In particular, a core make-up tank (CMT) has been installed in the rig to operate in a similar manner to those in many Advanced PWR designs. Three small break tests, GDE-24, GDE-34 and GDE-43 in the PACTEL facility were chosen for modelling with RELAP5. The objective of GDE-24 was to investigate CMT behaviour and in particular the effects of condensation in the CMT. The second test, GDE-34, was similar except that it had a smaller CMT and at the start of the test the water in the CMT and connecting pipework was at an elevated temperature. Test GDE-43 focused on conditions when the driving force for flow through the passive system injection system (PSIS) slowly disappears. Analysis of all tests reported here was carried out with RELAP5/MOD 3.2.1.2. The paper summarises the conclusions of all the tests. A critical part of the study revolved around modelling of the CMT. A model was developed to allow its detailed behaviour to be investigated more easily. This enabled recommendations for improving the condensation modelling in RELAP5 to be made. Apart from the wall condensation modelling issue, the implication of the work is that RELAP5/MOD 3.2.1.2 (a comparatively recent version of the code) is broadly adequate for these applications. (author)

  2. Steady state HTTR model in the RELAP5-3D

    Energy Technology Data Exchange (ETDEWEB)

    Scari, Maria E.; Reis, Patrícia A. L.; Costa, Antonella L.; Pereira, Claubia; Veloso, Maria A. F., E-mail: melizabethscari@yahoo.com, E-mail: patricialire@yahoo.com.br, E-mail: antonella@nuclear.ufmg.br, E-mail: claubia@nuclear.ufmg.br, E-mail: dora@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Instituto Nacional de Ciências e Tecnologia de Reatores Nucleares Inovadores/CNPQ (Brazil)

    2017-07-01

    The HTTR (High Temperature Engineering Test Reactor) is a high temperature gas-cooled reactor (HTGR). It is a helium-cooled and graphite-moderated with a thermal power of 30 MW, developed and operated by the Japan Atomic Energy Research Institute (JAERI). In a previous work, a thermal model for the HTTR has been developed using the RELAP5-3D code. In the present work, additional thermal analyses have been presented. Studies about the core neutronic simulation were also initiated and are described here. The code WIMSD-5B was used to generate the cross sections and the group constants necessary to the NESTLE neutron kinetic code incorporated in the RELAP5-3D. (author)

  3. RELAP5/MOD2 calculation of OECD LOFT test LP-FW-01

    International Nuclear Information System (INIS)

    Croxfod, M.G.; Harwood, C.; Hall, P.C.

    1992-04-01

    RELAP5/MOD2 is being used by GDCD for calculation of certain small break loss-of-coolant accidents and pressurized transients in the Sizewell ''B'' PWR. To test the ability of RELAP5/MOD2 to model the primary feed-and-bleed recovery procedure following a complete loss- of-feedwater event, post test calculations have been carried out of OECD LOFT test LP-FW-01. This report describes the comparison between the code calculations and the test data. It is found that although the standard version of RELAP5/MOD2 gives a reasonable prediction of the experimental transient, the long term pressure history is better calculated with a modified code version containing a revised horizontal stratification entrainment model. The latter allows an improved calculation of entrainment of liquid from the hot leg into the surge line. RELAP5/MOD2 is found to give a more accurate simulation of the experimental transient than was achieved in previous UK studies using RETRAN-02/MOD2

  4. Thermal-hydraulic analysis under partial loss of flow accident hypothesis of a plate-type fuel surrounded by two water channels using RELAP5 code

    OpenAIRE

    Itamar Iliuk; José Manoel Balthazar; Ângelo Marcelo Tusset; José Roberto Castilho Piqueira

    2016-01-01

    Thermal-hydraulic analysis of plate-type fuel has great importance to the establishment of safety criteria, also to the licensing of the future nuclear reactor with the objective of propelling the Brazilian nuclear submarine. In this work, an analysis of a single plate-type fuel surrounding by two water channels was performed using the RELAP5 thermal-hydraulic code. To realize the simulations, a plate-type fuel with the meat of uranium dioxide sandwiched between two Zircaloy-4 plates was prop...

  5. Coupling Computer Codes for The Analysis of Severe Accident Using A Pseudo Shared Memory Based on MPI

    International Nuclear Information System (INIS)

    Cho, Young Chul; Park, Chang-Hwan; Kim, Dong-Min

    2016-01-01

    As there are four codes in-vessel analysis code (CSPACE), ex-vessel analysis code (SACAP), corium behavior analysis code (COMPASS), and fission product behavior analysis code, for the analysis of severe accident, it is complex to implement the coupling of codes with the similar methodologies for RELAP and CONTEMPT or SPACE and CAP. Because of that, an efficient coupling so called Pseudo shared memory architecture was introduced. In this paper, coupling methodologies will be compared and the methodology used for the analysis of severe accident will be discussed in detail. The barrier between in-vessel and ex-vessel has been removed for the analysis of severe accidents with the implementation of coupling computer codes with pseudo shared memory architecture based on MPI. The remaining are proper choice and checking of variables and values for the selected severe accident scenarios, e.g., TMI accident. Even though it is possible to couple more than two computer codes with pseudo shared memory architecture, the methodology should be revised to couple parallel codes especially when they are programmed using MPI

  6. Coupling Computer Codes for The Analysis of Severe Accident Using A Pseudo Shared Memory Based on MPI

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Chul; Park, Chang-Hwan; Kim, Dong-Min [FNC Technology Co., Yongin (Korea, Republic of)

    2016-10-15

    As there are four codes in-vessel analysis code (CSPACE), ex-vessel analysis code (SACAP), corium behavior analysis code (COMPASS), and fission product behavior analysis code, for the analysis of severe accident, it is complex to implement the coupling of codes with the similar methodologies for RELAP and CONTEMPT or SPACE and CAP. Because of that, an efficient coupling so called Pseudo shared memory architecture was introduced. In this paper, coupling methodologies will be compared and the methodology used for the analysis of severe accident will be discussed in detail. The barrier between in-vessel and ex-vessel has been removed for the analysis of severe accidents with the implementation of coupling computer codes with pseudo shared memory architecture based on MPI. The remaining are proper choice and checking of variables and values for the selected severe accident scenarios, e.g., TMI accident. Even though it is possible to couple more than two computer codes with pseudo shared memory architecture, the methodology should be revised to couple parallel codes especially when they are programmed using MPI.

  7. Assessment and improvement of condensation model in RELAP5/MOD3

    Energy Technology Data Exchange (ETDEWEB)

    Rho, Hui Cheon; Choi, Kee Yong; Park, Hyeon Sik; Kim, Sang Jae [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Lee, Sang Il [Korea Power Engineering Co., Inc., Seoul (Korea, Republic of)

    1997-07-15

    The objective of this research is to remove the uncertainty of the condensation model through the assessment and improvement of the various heat transfer correlations used in the RELAP5/MOD3 code. The condensation model of the standard RELAP5/MOD3 code is systematically arranged and analyzed. A condensation heat transfer database is constructed from the previous experimental data on various condensation phenomena. Based on the constructed database, the condensation models in the code are assessed and improved. An experiment on the reflux condensation in a tube of steam generator in the presence of noncondensable gases is planned to acquire the experimental data.

  8. RELAP-7 Progress Report. FY-2015 Optimization Activities Summary

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Ray Alden [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    This report summarily documents the optimization activities on RELAP-7 for FY-2015. It includes the migration from the analytical stiffened gas equation of state for both the vapor and liquid phases to accurate and efficient property evaluations for both equilibrium and metastable (nonequilibrium) states using the Spline-Based Table Look-up (SBTL) method with the IAPWS-95 properties for steam and water. It also includes the initiation of realistic closure models based, where appropriate, on the U.S. Nuclear Regulatory Commission’s TRACE code. It also describes an improved entropy viscosity numerical stabilization method for the nonequilibrium two-phase flow model of RELAP-7. For ease of presentation to the reader, the nonequilibrium two-phase flow model used in RELAP-7 is briefly presented, though for detailed explanation the reader is referred to RELAP-7 Theory Manual [R.A. Berry, J.W. Peterson, H. Zhang, R.C. Martineau, H. Zhao, L. Zou, D. Andrs, “RELAP-7 Theory Manual,” Idaho National Laboratory INL/EXT-14-31366(rev. 1), February 2014].

  9. Web-based, Interactive, Nuclear Reactor Transient Analyzer using LabVIEW and RELAP5 (ATHENA)

    International Nuclear Information System (INIS)

    Kim, K. D.; Chung, B. D.; Rizwan-uddin

    2006-01-01

    In nuclear engineering, large system analysis codes such as RELAP5, TRAC-M, etc. play an important role in evaluating a reactor system behavior during a wide range of transient conditions. One limitation that restricts their use on a wider scale is that these codes often have a complicated I/O structure. This has motivated the development of GUI tools for best estimate codes, such as SNAP and ViSA, etc. In addition to a user interface, a greater degree of freedom in simulation and analyses of nuclear transient phenomena can be achieved if computer codes and their outputs are accessible from anywhere through the web. Such a web-based interactive interface can be very useful for geographically distributed groups when there is a need to share real-time data. Using mostly off-the-shelf technology, such a capability - a web-based transient analyzer based on a best-estimate code - has been developed. Specifically, the widely used best-estimate code RELAP5 is linked with a graphical interface. Moreover, a capability to web-cast is also available. This has been achieved by using the LabVIEW virtual instruments (VIs). In addition to the graphical display of the results, interactive control functions have also been added that allow operator's actions as well as, if permitted, by a distant user through the web

  10. NESTLE: A nodal kinetics code

    International Nuclear Information System (INIS)

    Al-Chalabi, R.M.; Turinsky, P.J.; Faure, F.-X.; Sarsour, H.N.; Engrand, P.R.

    1993-01-01

    The NESTLE nodal kinetics code has been developed for utilization as a stand-alone code for steady-state and transient reactor neutronic analysis and for incorporation into system transient codes, such as TRAC and RELAP. The latter is desirable to increase the simulation fidelity over that obtained from currently employed zero- and one-dimensional neutronic models and now feasible due to advances in computer performance and efficiency of nodal methods. As a stand-alone code, requirements are that it operate on a range of computing platforms from memory-limited personal computers (PCs) to supercomputers with vector processors. This paper summarizes the features of NESTLE that reflect the utilization and requirements just noted

  11. Applicability of RELAP5-3D for Thermal-Hydraulic Analyses of a Sodium-Cooled Actinide Burner Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    C. B. Davis

    2006-07-01

    The Actinide Burner Test Reactor (ABTR) is envisioned as a sodium-cooled, fast reactor that will burn the actinides generated in light water reactors to reduce nuclear waste and ease proliferation concerns. The RELAP5-3D computer code is being considered as the thermal-hydraulic system code to support the development of the ABTR. An evaluation was performed to determine the applicability of RELAP5-3D for the analysis of a sodium-cooled fast reactor. The applicability evaluation consisted of several steps, including identifying the important transients and phenomena expected in the ABTR, identifying the models and correlations that affect the code’s calculation of the important phenomena, and evaluating the applicability of the important models and correlations for calculating the important phenomena expected in the ABTR. The applicability evaluation identified code improvements and additional models needed to simulate the ABTR. The accuracy of the calculated thermodynamic and transport properties for sodium was also evaluated.

  12. Simulation of the IAEA's fourth Standard Problem Exercise small-break loss-of-coolant accident using RELAP5/MOD.3.1

    International Nuclear Information System (INIS)

    Cebull, P.P.; Hassan, Y.A.

    1995-01-01

    A small-break loss-of-coolant accident experiment conducted at the PMK-2 integral test facility in Hungary is analyzed using the RELAP5/MOD3.1 thermal-hydraulic code. The experiment simulated a 7.4% break in the cold leg of a VVER-440/213-type nuclear power plant as part of the International Atomic Energy Agency's Fourth Standard Problem Exercise (SPE-4). Blind calculations of the exercise are presented, and the timing of various events throughout the transient is discussed. A posttest analysis is performed in which the sensitivity of the calculated results is investigated. The code RELAP5 predicts most of the transient events well, although a few problems are noted, particularly the failure of RELAP5 to predict dryout in the core even through the collapsed liquid level fell below the top of the heated portion. A discrepancy between the predicted primary mass inventory distribution and the experimental data is identified. Finally, the primary and secondary pressures calculated by RELAP5 fell too rapidly during the latter part of the transient, resulting in rather large errors in the predicted timing of some pressure-actuated events

  13. Coupled fuel performance and thermal-hydraulics simulation with BISON and RELAP-7 at accident conditions

    Energy Technology Data Exchange (ETDEWEB)

    Martineau, R.C., E-mail: Richard.Martineau@inl.gov [Idaho National Laboratory, Idaho Falls, ID (United States)

    2015-07-01

    'Full text:' RELAP-7 is expected to be the next in the RELAP nuclear reactor safety/systems analysis application series developed at the Idaho National Laboratory (INL). The development of RELAP-7 began in 2011 to support the Risk Informed Safety Margins Characterization (RISMC) Pathway of Department of Energy's (DOE) Light Water Reactor Sustainability (LWRS) Program. The overall design goal of RELAP-7 is to take advantage of the previous thirty years of advancements in software design, numerical methods, and physical models in order to provide capabilities needed for the RISMC methodology and to support modern nuclear power safety analysis. RELAP-7 is built using the INL's modern scientific software development framework, MOOSE (Multi-physics Object Oriented Simulation Environment). MOOSE provides improved implicit numerical schemes, including higher-order integration in both space and time, and yielding converged second-order accuracy for RELAP-7. The code structure is based on multiple physical component models such as pipes, junctions, pumps, etc. This component-based software architecture allows RELAP-7 to quickly adopt different physical models for different applications. One of the main advantages of building RELAP-7 on the MOOSE framework is that tight coupling with other MOOSE-based applications solving physics not present in RELAP-7 requires little to no additional lines of code. For example, the RELAP-7 core channel component is based upon a one-dimensional flow channel and a three-zone two-dimensional heat structure designed to represent fuel, gap, and cladding conjugate heat transfer with the coolant. However, the RELAP-7 application does not carry the fuels performance physics to analyze irradiated fuel, especially for accident scenarios. Here, we demonstrate the tightly coupled capability of the BISON nuclear fuels performance application with RELAP-7 for the station black out (SBO) accident scenario (Fukushima type event) and

  14. RELAP5 nuclear plant analyzer capabilities

    International Nuclear Information System (INIS)

    Wagner, R.J.; Ransom, V.H.

    1982-01-01

    An interactive execution capability has been developed for the RELAP5 code which permits it to be used as a Nuclear Plant Analyzer. This capability has been demonstrated using a simplified primary and secondary loop model of a PWR. A variety of loss-of-feed-water accidents have been simulated using this model. The computer execution time on a CDC Cyber 176 is one half of the transient simulation time so that the results can be displayed in real time. The results of the demonstration problems are displayed in digital form on a color schematic of the plant model using a Textronics 4027 CRT terminal. The interactive feature allows the user to enter commands in much the same manner as a reactor operator

  15. Break model comparison in different RELAP5 versions

    International Nuclear Information System (INIS)

    Parzer, I.

    2003-01-01

    The presented work focuses on the break flow prediction in RELAP5/MOD3 code, which is crucial to predict core uncovering and heatup during the Small Break Loss-of-Coolant Accidents (SB LOCA). The code prediction has been compared to the IAEA-SPE-4 experiments conducted on the PMK-2 integral test facilities in Hungary. The simulations have been performed with MOD3.2.2 Beta, MOD3.2.2 Gamma, MOD3.3 Beta and MOD3.3 frozen code version. In the present work we have compared the Ransom-Trapp and Henry-Fauske break model predictions. Additionally, both model predictions have been compared to itself, when used as the main modeling tool or when used as another code option, as so-called 'secret developmental options' on input card no.1. (author)

  16. Two-phase wall friction model for the trace computer code

    International Nuclear Information System (INIS)

    Wang Weidong

    2005-01-01

    The wall drag model in the TRAC/RELAP5 Advanced Computational Engine computer code (TRACE) has certain known deficiencies. For example, in an annular flow regime, the code predicts an unphysical high liquid velocity compared to the experimental data. To address those deficiencies, a new wall frictional drag package has been developed and implemented in the TRACE code to model the wall drag for two-phase flow system code. The modeled flow regimes are (1) annular/mist, (2) bubbly/slug, and (3) bubbly/slug with wall nucleation. The new models use void fraction (instead of flow quality) as the correlating variable to minimize the calculation oscillation. In addition, the models allow for transitions between the three regimes. The annular/mist regime is subdivided into three separate regimes for pure annular flow, annular flow with entrainment, and film breakdown. For adiabatic two-phase bubbly/slug flows, the vapor phase primarily exists outside of the boundary layer, and the wall shear uses single-phase liquid velocity for friction calculation. The vapor phase wall friction drag is set to zero for bubbly/slug flows. For bubbly/slug flows with wall nucleation, the bubbles are presented within the hydrodynamic boundary layer, and the two-phase wall friction drag is significantly higher with a pronounced mass flux effect. An empirical correlation has been studied and applied to account for nucleate boiling. Verification and validation tests have been performed, and the test results showed a significant code improvement. (authors)

  17. Analysis of steam generator behaviour in nuclear power plant with computer program RELAP5; Analiza delovanja uparjalnika jedrske elektrarne s programom RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Zeljko, M; Gregoric, M; Peterlin, G [Institut ' Jozef Stefan' , Ljubljana (Yugoslavia)

    1983-07-01

    Analyses of nuclear power plant behaviour are made with large computer programs. We used RELAP5/MOD1/CYCLE001, which was developed in Idaho National Engineering laboratory. Input model was prepared to analyze transients in steam generator of NPP Krsko. We found out that this version had a lot of faults so we intend to implement a new cycle. First experience shows the whole complexity of such analysis from technical and economical viewpoints. (author)

  18. Preliminary assessment of PWR Steam Generator modelling in RELAP5/MOD3

    International Nuclear Information System (INIS)

    Preece, R.J.; Putney, J.M.

    1993-07-01

    A preliminary assessment of Steam Generator (SG) modelling in the PWR thermal-hydraulic code RELAP5/MOD3 is presented. The study is based on calculations against a series of steady-state commissioning tests carried out on the Wolf Creek PWR over a range of load conditions. Data from the tests are used to assess the modelling of primary to secondary side heat transfer and, in particular, to examine the effect of reverting to the standard form of the Chen heat transfer correlation in place of the modified form applied in RELAP5/MOD2. Comparisons between the two versions of the code are also used to show how the new interphase drag model in RELAP5/MOD3 affects the calculation of SG liquid inventory and the void fraction profile in the riser

  19. RELAP5 model for TRIGA 14 MWt

    International Nuclear Information System (INIS)

    Negut, Gheorghe; Prisecaru, Ilie)

    2003-01-01

    forced convection. When, after 900 seconds (15 minutes), the emergency pump is stopped, the flow reverses once again and the residual heat is removed this time by natural convection. The comparison between the fuel temperature recorded during LOFA test and the RELAP5 results is presented. Also, for comparison, the SAR fuel temperature evaluation made with the BLOOST7 code is given. It can be observed that the initial fuel temperature evaluated with RELAP5, 492.5 deg C is practically the same with that recorded in the LOFA test, 475 deg C. Only the BLOOST7 initial fuel temperature is over evaluated to 750 deg C. The RELAP5 tends to underestimate the heat transfer, which is a conservative feature, and so the fuel temperature given by RELAP5 is bigger. The temperature evolution is quite similar and after the emergency pump stops the temperature rise gradient is the same: 13 degrees C. In the second test TRIGA reactor is operated at the nominal power of 14 MW and the main pumps and emergency pump are stopped simultaneously. The reactor is tripped by the low flow rate signal at the level of 441.1 kg/sec. The RELAP5 analysis shows that after 4 seconds the flow rate is reversed and the residual heat is removed by the natural convection loop established through the core and closed through the experimental channels. The comparison between the fuel temperature recorded during the tests and the RELAP5 results is presented. The temperature evolution is quite similar with higher values for RELAP5. It can be observed that during the test evolution the temperature slightly rises up after 1 minute from the test initiation in a similar way. This analysis was made for the mixed HEU-LEU 35 fuel bundles TRIGA core and is used for the revised SAR

  20. Assessment of PWR Steam Generator modelling in RELAP5/MOD2

    International Nuclear Information System (INIS)

    Putney, J.M.; Preece, R.J.

    1993-06-01

    An assessment of Steam Generator (SG) modelling in the PWR thermal-hydraulic code RELAP5/MOD2 is presented. The assessment is based on a review of code assessment calculations performed in the UK and elsewhere, detailed calculations against a series of commissioning tests carried out on the Wolf Creek PWR and analytical investigations of the phenomena involved in normal and abnormal SG operation. A number of modelling deficiencies are identified and their implications for PWR safety analysis are discussed -- including methods for compensating for the deficiencies through changes to the input deck. Consideration is also given as to whether the deficiencies will still be present in the successor code RELAP5/MOD3

  1. Coupled RELAP5/GOTHIC model for IRIS SBLOCA analysis

    International Nuclear Information System (INIS)

    Grgic, D.; Cavlina, N.; Bajs, T.; Oriani, L.; Conway, L. E.

    2004-01-01

    . However, the time that would be needed to develop new codes where all required models are properly incorporated, to build user experience, and to qualify the code would be prohibitively long and expensive. Therefore, the coupling of the thermal-hydraulic and containment codes can be an interesting approach and compromise between two modeling strategies mentioned above. Separate, existing computer codes can be coupled providing new capabilities without spending too much time in development and with possibility to use existing experience and perform code verification and validation only for the coupling portion of the new code. This coupling is usually performed as an extension of the classical calculation approach and it is localized at the physical points where communication between system and containment exists. For IRIS, it was decided to develop an explicit coupling of RELAP5/mod3.3, and one of the earlier versions of the GOTHIC code available at University of Zagreb, GOTHIC 3.4e; thus taking advantage of the rather large experience base in the use of the RELAP5 and GOTHIC codes as well as knowledge of their internal structure The primary goal was to explore applicability of coupled code to safety analyses of the new reactor systems where the primary system and containment closely interact. The chosen coupling strategy is simple and basic operation of constituent codes and corresponding input data are unaffected by the coupling process. This paper describes the coupled code as well as the development of the preliminary IRIS SBLOCA evaluation model and its use. Also, a discussion on the verification and validation of this methodology is provided.(author)

  2. Application of RELAP5 to a pipe blowdown experiment

    International Nuclear Information System (INIS)

    Carlson, K.E.; Ransom, V.H.; Wagner, R.J.

    1980-01-01

    The application of the RELAP5 computer program to a pipe blowdown experiment is described in this paper. The basic hydrodynamic model, constitutive relations, and special process models included in RELAP5 are also briefly discussed. The results of this application confirm the effectiveness of using a choked flow model

  3. AP1000 passive core cooling system pre-operational tests procedure definition and simulation by means of Relap5 Mod. 3.3 computer code

    International Nuclear Information System (INIS)

    Lioce, D.; Asztalos, M.; Alemberti, A.; Barucca, L.; Frogheri, M.; Saiu, G.

    2012-01-01

    Highlights: ► Two AP1000 Core Make-up Tanks pre-operational tests procedures have been defined. ► The two tests have been simulated by means of the Relap5 computer code. ► Results show the tests can be successfully performed with the selected procedures. - Abstract: The AP1000 ® plant is an advanced Pressurized Water Reactor designed and developed by Westinghouse Electric Company which relies on passive safety systems for core cooling, containment isolation and containment cooling, and maintenance of main control room emergency habitability. The AP1000 design obtained the Design Certification by NRC in January 2006, as Appendix D of 10 CFR Part 52, and it is being built in two locations in China. The AP1000 plant will be the first commercial nuclear power plant to rely on completely passive safety systems for core cooling and its licensing process requires the proper operation of these systems to be demonstrated through some pre-operational tests to be conducted on the real plant. The overall objective of the test program is to demonstrate that the plant has been constructed as designed, that the systems perform consistently with the plant design, and that activities culminating in operation at full licensed power including initial fuel load, initial criticality, and power increase to full load are performed in a controlled and safe manner. Within this framework, Westinghouse Electric Company and its partner Ansaldo Nucleare S.p.A. have strictly collaborated, being Ansaldo Nucleare S.p.A. in charge of the simulation of some pre-operational tests and supporting Westinghouse in the definition of tests procedures. This paper summarizes the work performed at Ansaldo Nucleare S.p.A. in collaboration with Westinghouse Electric Company for the Core Makeup Tank (CMT) tests, i.e. the CMTs hot recirculation test and the CMTs draindown test. The test procedure for the two selected tests has been defined and, in order to perform the pre-operational tests simulations, a

  4. AP1000 passive core cooling system pre-operational tests procedure definition and simulation by means of Relap5 Mod. 3.3 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Lioce, D., E-mail: donato.lioce@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Asztalos, M., E-mail: asztalmj@westinghouse.com [Westinghouse Electric Company, Cranberry Twp, PA 16066 (United States); Alemberti, A., E-mail: alessandro.alemberti@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Barucca, L. [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Frogheri, M., E-mail: monicalinda.frogheri@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Saiu, G., E-mail: gianfranco.saiu@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Two AP1000 Core Make-up Tanks pre-operational tests procedures have been defined. Black-Right-Pointing-Pointer The two tests have been simulated by means of the Relap5 computer code. Black-Right-Pointing-Pointer Results show the tests can be successfully performed with the selected procedures. - Abstract: The AP1000{sup Registered-Sign} plant is an advanced Pressurized Water Reactor designed and developed by Westinghouse Electric Company which relies on passive safety systems for core cooling, containment isolation and containment cooling, and maintenance of main control room emergency habitability. The AP1000 design obtained the Design Certification by NRC in January 2006, as Appendix D of 10 CFR Part 52, and it is being built in two locations in China. The AP1000 plant will be the first commercial nuclear power plant to rely on completely passive safety systems for core cooling and its licensing process requires the proper operation of these systems to be demonstrated through some pre-operational tests to be conducted on the real plant. The overall objective of the test program is to demonstrate that the plant has been constructed as designed, that the systems perform consistently with the plant design, and that activities culminating in operation at full licensed power including initial fuel load, initial criticality, and power increase to full load are performed in a controlled and safe manner. Within this framework, Westinghouse Electric Company and its partner Ansaldo Nucleare S.p.A. have strictly collaborated, being Ansaldo Nucleare S.p.A. in charge of the simulation of some pre-operational tests and supporting Westinghouse in the definition of tests procedures. This paper summarizes the work performed at Ansaldo Nucleare S.p.A. in collaboration with Westinghouse Electric Company for the Core Makeup Tank (CMT) tests, i.e. the CMTs hot recirculation test and the CMTs draindown test. The test procedure for the two

  5. Comparison of SCDAP/RELAP5/MOD3 to TRAC-PF1/MOD1 for timing analysis of PWR fuel pin failures

    International Nuclear Information System (INIS)

    Jones, K.R.; Katsma, K.R.; Wade, N.L.; Siefken, L.J.; Straka, M.

    1991-01-01

    A comparison has been made of SCDAP/RELAP5/MOD3- and TRAC-PF1/MOD1- based calculations of the fuel pin failure timing (time from containment isolation signal to first fuel pin failure) in a loss-of-coolant accident (LOCA). The two codes were used to calculate the thermal-hydraulic boundary conditions for a complete, double-ended, offset-shear break of a cold leg in a Westinghouse 4-loop pressurized water reactor. Both calculations used the FRAPCON-2 code to calculate the steady-state fuel rod behavior and the FRAP-T6 code to calculate the transient fuel rod behavior. The analysis was performed for 16 combinations of fuel burnups and power peaking factors extending up to the Technical Specifications limits. While all calculations were made on a best-estimate basis, the SCDAP/RELAP5/MOD3 code has not yet been fully assessed for large-break LOCA analysis. The results indicate that SCDAP/RELAP5/MOD3 yields conservative fuel pin failure timing results in comparison to those generated using TRAC-PF1/MOD1. 7 refs., 5 figs

  6. RELAP5/MOD3 analysis of a heated channel in downflow

    International Nuclear Information System (INIS)

    Dimenna, R.A.; Qureshi, Z.H.; Boman, A.L.

    1993-01-01

    The onset of flow instability (OFI) is a significant phenomenon affecting the determination of a safe operating power limit in the Savannah River Site production reactors. Tests performed at Columbia University for a single tube with uniform axial and azimuthal heating have been analyzed with RELAP5/NPR, Version 0, a version of RELAP5/MOD3. The tests include water flow rates from 3.2 x l0 -4 - 2.l x 10 -3 m 3 /s (5 - 33 gpm), Reynolds numbers from 30,000 - 400,000, and surface heat fluxes from 0 - 3.2 x l0 6 w/m 2 (0 - 1,000,000 Btu/hr- ft 2 ). Pressure drop versus flow rate curves were mapped for both fixed pressure boundary conditions and fixed flow boundary conditions. RELAP5/MOD3 results showed fair agreement with data for both types of boundary conditions, and good internal consistency between calculations using the two different types of boundary conditions. Under single-phase unheated conditions, the code overpredicted the pressure drop by 22 - 34%. Under single-phase heated conditions, the overprediction increased to as much as 55%. For those tests where two-phase conditions were observed at the channel exit, RELAP5 predicted lower flows than seen in the tests before voiding occurred

  7. MARS CODE MANUAL VOLUME III - Programmer's Manual

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Hwang, Moon Kyu; Jeong, Jae Jun; Kim, Kyung Doo; Bae, Sung Won; Lee, Young Jin; Lee, Won Jae

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This programmer's manual provides a complete list of overall information of code structure and input/output function of MARS. In addition, brief descriptions for each subroutine and major variables used in MARS are also included in this report, so that this report would be very useful for the code maintenance. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  8. Full Scope Modeling and Analysis on the Secondary Circuit of Chinese Large-Capacity Advanced PWR Based on RELAP5 Code

    Directory of Open Access Journals (Sweden)

    Dao-gang Lu

    2015-01-01

    Full Text Available Chinese large-capacity advanced PWR under construction in China is a new and indispensable reactor type in the developing process of NPP fields. At the same time of NPP construction, accident sequences prediction and operators training are in progress. Since there are some possible events such as feedwater pumps trip in secondary circuit may lead to severe accident in NPP, training simulators and engineering simulators of CI are necessary. And, with an increasing proportion of nuclear power in China, NPP will participate in regulating peak load in power network, which requires accuracy calculation and control of secondary circuit. In order to achieve real-time and full scope simulation in the power change transient and accident scenarios, RELAP5/MOD 3.4 code has been adopted to model the secondary circuit for its advantage of high calculation accuracy. This paper describes the model of steady state and turbine load transient from 100% to 40% of secondary circuit using RELAP5 and provides a reasonable equivalent method to solve the calculation divergence problem caused by dramatic two-phase condition change while guaranteeing the heat transfer efficiency. The validation of the parameters shows that all the errors between the calculation values and design values are reasonable and acceptable.

  9. Applicability of RELAP5 for safety analysis of AP600 and PIUS reactors

    International Nuclear Information System (INIS)

    Motloch, C.G.; Modro, S.M.

    1990-01-01

    An assessment of the applicability of using RELAP5 for performing safety analyses of the AP600 and PIUS advanced reactor concepts is being performed. This ongoing work is part of a larger safety assessment of advanced reactors sponsored by the United States Nuclear Regulatory Commission. RELAP5 models and correlations are being reviewed from the perspective of the new AP600 and PIUS phenomena and features that could be important to reactor safety. The purpose is to identify those areas in which new mathematical models of physical phenomena would be required to be added to RELAP5. In most cases, the AP600 and PIUS designs and systems and the planned and off-normal operations are similar enough to current Pressurized Water Reactors (PWR) that RELAP5 safety analysis applicability is unchanged. However, for AP600 the single most important systemic and phenomenological difference between it and current PWRs is in the close coupling between the reactor system and the containment during postulated Loss of Coolant Accident (LOCA) events. This close coupling may require the addition of some thermal-hydraulic models to RELAP5. And for PIUS, the most important new feature is the thermal density locks. These and other important safety-related features are discussed. This document presents general descriptions of RELAP5, AP600, and PIUS, describes the new features and phenomena of the reactors, and discusses the code/reactors safety-related issues. 32 refs., 4 figs., 2 tabs

  10. Qualification of FEAST 3.0 and FEAT 4.0 computer codes

    International Nuclear Information System (INIS)

    Xu, Z.; Lai, L.; Sim, K.-S.; Huang, F.; Wong, B.

    2005-01-01

    FEAST (Finite Element Analysis for Stresses) is an AECL computer code used to assess the structural integrity of the CANDU fuel element. FEAST models the thermo-elastic, thermo-elasto-plastic and creep deformations in CANDU fuel. FEAT (Finite Element Analysis for Temperature) is another AECL computer code and is used to assess the thermal integrity of fuel elements. FEAT models the steady-state and transient heat flows in CANDU fuel, under conditions such as flux depression, end flux peaking, temperature-dependent thermal conductivity, and non-uniform time-dependent boundary conditions. Both computer programs are used in design and qualification analyses of CANDU fuel. Formal qualifications (including coding verification and validation) of both codes were performed, in accordance with AECL software quality assurance (SQA) manual and procedures that are consistent with CSA N286.7-99. Validation of FEAST 3.0 shows very good agreement with independent analytical solutions or measurements. Validation of FEAT 4.0 also shows very good agreement with independent WIMS-AECL calculations, analytical solutions, ANSYS calculations and measurement. (author)

  11. Qualification of FEAST 3.0 and FEAT 4.0 computer codes

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z.; Lai, L.; Sim, K.-S.; Huang, F.; Wong, B. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada)

    2005-07-01

    FEAST (Finite Element Analysis for Stresses) is an AECL computer code used to assess the structural integrity of the CANDU fuel element. FEAST models the thermo-elastic, thermo-elasto-plastic and creep deformations in CANDU fuel. FEAT (Finite Element Analysis for Temperature) is another AECL computer code and is used to assess the thermal integrity of fuel elements. FEAT models the steady-state and transient heat flows in CANDU fuel, under conditions such as flux depression, end flux peaking, temperature-dependent thermal conductivity, and non-uniform time-dependent boundary conditions. Both computer programs are used in design and qualification analyses of CANDU fuel. Formal qualifications (including coding verification and validation) of both codes were performed, in accordance with AECL software quality assurance (SQA) manual and procedures that are consistent with CSA N286.7-99. Validation of FEAST 3.0 shows very good agreement with independent analytical solutions or measurements. Validation of FEAT 4.0 also shows very good agreement with independent WIMS-AECL calculations, analytical solutions, ANSYS calculations and measurement. (author)

  12. Analysis, by RELAP5 code, of boron dilution phenomena in a mid-loop operation transient, performed in PKL III F2.1 RUN 1 test

    International Nuclear Information System (INIS)

    Mascari, F.; Vella, G.; Del Nevo, A.; D'Auria, F.

    2007-01-01

    The present paper deals with the post test analysis and accuracy quantification of the test PKL III F2.1 RUN 1 by RELAP5/Mod3.3 code performed in the framework of the international OECD/SETH PKL III Project. The PKL III is a full-height integral test facility (ITF) that models the entire primary system and most of the secondary system (except for turbine and condenser) of pressurized water reactor of KWU design of the 1300-MW (electric) class on a scale of 1:145. Detailed design was based to the largest possible extent on the specific data of Philippsburg nuclear power plant, unit 2. As for the test facilities of this size, the scaling concept aims to simulate overall thermal hydraulic behavior of the full-scale power plant [1]. The main purpose of the project is to investigate PWR safety issues related to boron dilution and in particular this experiment investigates (a) the boron dilution issue during mid-loop operation and shutdown conditions, and (b) assessing primary circuit accident management operations to prevent boron dilution as a consequence of loss of heat removal [2]. In this work the authors deal with a systematic procedure (developed at the university of Pisa) for code assessment and uncertainty qualification and its application to RELAP5 system code. It is used to evaluate the capability of RELAP5 to reproduce the thermal hydraulics of an inadvertent boron dilution event in a PWR. The quantitative analysis has been performed adopting the Fast Fourier Transform Based Method (FFTBM), which has the capability to quantify the errors in code predictions as compared to the measured experimental signal. (author)

  13. Validation of the transportation computer codes HIGHWAY, INTERLINE, RADTRAN 4, and RISKIND

    International Nuclear Information System (INIS)

    Maheras, S.J.; Pippen, H.K.

    1995-05-01

    The computer codes HIGHWAY, INTERLINE, RADTRAN 4, and RISKIND were used to estimate radiation doses from the transportation of radioactive material in the Department of Energy Programmatic Spent Nuclear Fuel Management and Idaho National Engineering Laboratory Environmental Restoration and Waste Management Programs Environmental Impact Statement. HIGHWAY and INTERLINE were used to estimate transportation routes for truck and rail shipments, respectively. RADTRAN 4 was used to estimate collective doses from incident-free transportation and the risk (probability x consequence) from transportation accidents. RISKIND was used to estimate incident-free radiation doses for maximally exposed individuals and the consequences from reasonably foreseeable transportation accidents. The purpose of this analysis is to validate the estimates made by these computer codes; critiques of the conceptual models used in RADTRAN 4 are also discussed. Validation is defined as ''the test and evaluation of the completed software to ensure compliance with software requirements.'' In this analysis, validation means that the differences between the estimates generated by these codes and independent observations are small (i.e., within the acceptance criterion established for the validation analysis). In some cases, the independent observations used in the validation were measurements; in other cases, the independent observations used in the validation analysis were generated using hand calculations. The results of the validation analyses performed for HIGHWAY, INTERLINE, RADTRAN 4, and RISKIND show that the differences between the estimates generated using the computer codes and independent observations were small. Based on the acceptance criterion established for the validation analyses, the codes yielded acceptable results; in all cases the estimates met the requirements for successful validation

  14. MARS CODE MANAUAL VOLUME IV - Developmental Assessment Report

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Jeong, Jae Jun; Hwang, Moon Kyu; Lee, Won Jae; Lee, Young Jin; Lee, Seung Wook; Kim, Kyung Doo; Bae, Sung Won

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This assessment manual provides a complete list of code assessment results of the MARS code for various conceptual problem, separate effect test and integral effect test. From these validation procedures, the soundness and accuracy of the MARS code has been confirmed. The overall structure of the input is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  15. The effect of code user and boundary conditions on RELAP calculations of MTR research reactor transient scenarios

    Directory of Open Access Journals (Sweden)

    Khedr Ahmed

    2005-01-01

    Full Text Available The safety evaluation of nuclear power and re search reactors is a very important step before their construction and during their operation. This evaluation based on the best estimate calculations requires qualified codes qualified users, and qualified nodalizations. The effect of code users on the RELAP5 results during the analysis of loss of flow transient in MTR research reactors is presented in this pa per. To clarify this effect, two nodalizations for research reactor different in the simulation of the open water surface boundary conditions of the reactor pool have been used. Very different results are obtained with few choices for code users. The core natural circulation flow with the be ginning of core boiling doesn't stop but in creases. The in creasing in the natural circulation flow shifts out the boiling from the core and the clad temperature decreases be low the local saturation temperature.

  16. Development of the containment transient analysis code for the passive reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Young Dong; Kim, Young In; Bae, Yoon Young; Chang, Moon Hi [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-05-01

    This study was performed to develop the analysis tools for the passively cooled steel containment and to construct the integrated code system which can analyze a thermal hydraulic behavior of the containment and reactor system during a loss of coolant accident. The computer code CONTEMPT4/MOD5/PCCS was developed by incorporating the passive containment cooling models to the containment pressure and temperature transient analysis computer code CONTEMPT4/MOD5. The integrated reactor thermal hydraulic analysis code system for passive reactor was constructed by coupling the best estimate thermal hydraulic system analysis code RELAP5/MOD3 and CONTEMPT4/MOD5/PCCS through the process control method. In addition, to evaluate the applicability of the code the CONTEMPT4/MOD5/PCCS was applied to the SMART(System-Integrated Modular Advanced Reactor). The pressure and temperature transient following the small break LOCA of SMART was analysed by modeling the safeguard vessel using both the newly added passive containment cooling model and existing pool model. (author). 16 refs., 22 figs., 7 tabs.

  17. Automation of RELAP5 input calibration and code validation using genetic algorithm

    International Nuclear Information System (INIS)

    Phung, Viet-Anh; Kööp, Kaspar; Grishchenko, Dmitry; Vorobyev, Yury; Kudinov, Pavel

    2016-01-01

    Highlights: • Automated input calibration and code validation using genetic algorithm is presented. • Predictions generally overlap experiments for individual system response quantities (SRQs). • It was not possible to predict simultaneously experimental maximum flow rate and oscillation period. • Simultaneous consideration of multiple SRQs is important for code validation. - Abstract: Validation of system thermal-hydraulic codes is an important step in application of the codes to reactor safety analysis. The goal of the validation process is to determine how well a code can represent physical reality. This is achieved by comparing predicted and experimental system response quantities (SRQs) taking into account experimental and modelling uncertainties. Parameters which are required for the code input but not measured directly in the experiment can become an important source of uncertainty in the code validation process. Quantification of such parameters is often called input calibration. Calibration and uncertainty quantification may become challenging tasks when the number of calibrated input parameters and SRQs is large and dependencies between them are complex. If only engineering judgment is employed in the process, the outcome can be prone to so called “user effects”. The goal of this work is to develop an automated approach to input calibration and RELAP5 code validation against data on two-phase natural circulation flow instability. Multiple SRQs are used in both calibration and validation. In the input calibration, we used genetic algorithm (GA), a heuristic global optimization method, in order to minimize the discrepancy between experimental and simulation data by identifying optimal combinations of uncertain input parameters in the calibration process. We demonstrate the importance of the proper selection of SRQs and respective normalization and weighting factors in the fitness function. In the code validation, we used maximum flow rate as the

  18. Automation of RELAP5 input calibration and code validation using genetic algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Phung, Viet-Anh, E-mail: vaphung@kth.se [Division of Nuclear Power Safety, Royal Institute of Technology, Roslagstullsbacken 21, 10691 Stockholm (Sweden); Kööp, Kaspar, E-mail: kaspar@safety.sci.kth.se [Division of Nuclear Power Safety, Royal Institute of Technology, Roslagstullsbacken 21, 10691 Stockholm (Sweden); Grishchenko, Dmitry, E-mail: dmitry@safety.sci.kth.se [Division of Nuclear Power Safety, Royal Institute of Technology, Roslagstullsbacken 21, 10691 Stockholm (Sweden); Vorobyev, Yury, E-mail: yura3510@gmail.com [National Research Center “Kurchatov Institute”, Kurchatov square 1, Moscow 123182 (Russian Federation); Kudinov, Pavel, E-mail: pavel@safety.sci.kth.se [Division of Nuclear Power Safety, Royal Institute of Technology, Roslagstullsbacken 21, 10691 Stockholm (Sweden)

    2016-04-15

    Highlights: • Automated input calibration and code validation using genetic algorithm is presented. • Predictions generally overlap experiments for individual system response quantities (SRQs). • It was not possible to predict simultaneously experimental maximum flow rate and oscillation period. • Simultaneous consideration of multiple SRQs is important for code validation. - Abstract: Validation of system thermal-hydraulic codes is an important step in application of the codes to reactor safety analysis. The goal of the validation process is to determine how well a code can represent physical reality. This is achieved by comparing predicted and experimental system response quantities (SRQs) taking into account experimental and modelling uncertainties. Parameters which are required for the code input but not measured directly in the experiment can become an important source of uncertainty in the code validation process. Quantification of such parameters is often called input calibration. Calibration and uncertainty quantification may become challenging tasks when the number of calibrated input parameters and SRQs is large and dependencies between them are complex. If only engineering judgment is employed in the process, the outcome can be prone to so called “user effects”. The goal of this work is to develop an automated approach to input calibration and RELAP5 code validation against data on two-phase natural circulation flow instability. Multiple SRQs are used in both calibration and validation. In the input calibration, we used genetic algorithm (GA), a heuristic global optimization method, in order to minimize the discrepancy between experimental and simulation data by identifying optimal combinations of uncertain input parameters in the calibration process. We demonstrate the importance of the proper selection of SRQs and respective normalization and weighting factors in the fitness function. In the code validation, we used maximum flow rate as the

  19. Post-test analysis of LOBI BT-01 using RELAP5/MOD2 and RELAP5/MOD3

    International Nuclear Information System (INIS)

    Holmes, B.J.

    1991-08-01

    LOBI is a high pressure, electrically heated integral system test facility simulating a KWU 1300 MW PWR scaled 1:712 by volume, although full scale has been maintained in the vertical direction. This report describes the results of an analysis of test BT-01, which simulates a 10% steam line break. The bulk of the analysis was performed using the Project Version of RELAP5/MOD2, with additional calculations using RELAP5/MOD3 for comparison. The codes provided generally good agreement with data. In particular, the break flows were well modelled, although the mass flow data proved to be unreliable, and this conclusion had to be derived from interpreting other signals. RELAP over-predicted primary/secondary heat transfer in the broken loop, however, leading to a more rapid cool-down of the primary circuit. Furthermore, the primary side pressure response was critically dependent upon the pressuriser behaviour, and the correct timing of the uncovery of the surge line. Inter-phase drag was not well predicted in the broken loop steam generator intermals, although some improvement was seen in the RELAP5/MOD3 predictions. MOD3 gave a reduction in primary/secondary heat transfer during the test pre-conditioning phase, resulting in a lower secondary side pressure at the start of the transient compared with MOD2. (author)

  20. MARS CODE MANUAL VOLUME V: Models and Correlations

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Bae, Sung Won; Lee, Seung Wook; Yoon, Churl; Hwang, Moon Kyu; Kim, Kyung Doo; Jeong, Jae Jun

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This models and correlations manual provides a complete list of detailed information of the thermal-hydraulic models used in MARS, so that this report would be very useful for the code users. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  1. Development of a qualified nodalization for small-break LOCA transient analysis in PSB-VVER integral test facility by RELAP5 system code

    Energy Technology Data Exchange (ETDEWEB)

    Shahedi, S. [Department of Energy Engineering, Sharif University of Technology, Azadi Street, Tehran (Iran, Islamic Republic of); Jafari, J., E-mail: jalil_jafari@yahoo.co [Reactors and Accelerators R and D School, Nuclear Science and Technology Research Institute, North Kargar Street, Tehran (Iran, Islamic Republic of); Boroushaki, M. [Department of Energy Engineering, Sharif University of Technology, Azadi Street, Tehran (Iran, Islamic Republic of); D' Auria, F. [DIMNP, University of Pisa, Via Diotisalvi 2, 56126 Pisa (Italy)

    2010-10-15

    This paper deals with development and qualification of a nodalization for modeling of the PSB-VVER integral test facility (ITF) by RELAP5/MOD3.2 code and prediction of its primary and secondary systems behaviors at steady state and transient conditions. The PSB-VVER is a full-height, 1/300 volume and power scale representation of a VVER-1000 NPP. A RELAP5 nodalization has been developed for PSB-VVER modeling and a nodalization qualification process has been applied for the developed nodalization at steady state and transient levels and a qualified nodalization has been proposed for modeling of the PSB ITF. The 11% small-break loss-of-coolant-accident (SBLOCA), i.e. rupture of one of the hydroaccumulators (HA) injection lines in the upper plenum (UP) region of reactor pressure vessel (RPV) below the hot legs (HL), inlets has been considered for nodalization qualification process. The influence of the different steam generator (SG) nodalizations on the RELAP5 results and on the nodalization qualification process has been examined. The 'steady state' qualification level includes checking the correctness of the initial and boundary conditions and geometrical fidelity. In the 'transient' qualification level, the time dependent results of the code calculation are compared with the experimental time trends from both the qualitative and quantitative point of view. For quantitative assessment of the results, a Fast Fourier Transform Based Method (FFTBM) has been used. The FFTBM was used to establish a range in which the steam generators nodalizations can vary.

  2. RELAP5/MOD2 code assessment for the Semiscale Mod-2C Test S-LH-1

    International Nuclear Information System (INIS)

    Fineman, C.P.

    1986-01-01

    RELAP5/MOD2, Cycle 36.02, was assessed using data from Semiscale Mod-2C experiment S-LH-1. The major phenomena that occurred during the experiment were calculated by RELAP5/MOD2, although the duration and the magnitude of their effect on the transient were not always well calculated. Areas defined where further work was needed to improve the RELAP5 calculation include: (1) the system energy balance, (2) core interfacial drag, and 3) the heat transfer logic rod dryout criterion

  3. Calculation of pre and post-test of the third. proposed standard problem exercise, for the PMK-NVH-IAEA experiment using the RELAP4/MOD5 and RELAP5/MOD1

    International Nuclear Information System (INIS)

    Neves Conti, T. das; Sabundjian, G.; Oliveira Neto, J.M. de

    1992-01-01

    The results of RELAP4/MOD5 and RELAP5/MOD1 modeling tests against the steam generator tube rupture experiments performed at PMK-NVH Experimental Loop Facility (IAEA-Standard Problem Exercise-3) are presented in the report. The pre and post-test results, when compared against the experimental data were satisfactorily good, except a discrepancy in the steam-generator relief valve opening time. (author)

  4. Application of UPTF data for modeling liquid draindown in the downcomer region of a PWR using RELAP5/MOD2-B&W

    Energy Technology Data Exchange (ETDEWEB)

    Wissinger, G.; Klingenfus, J. [B & W Nuclear Technologies, Lynchburg, VA (United States)

    1995-09-01

    B&W Nuclear Technologies (BWNT) currently uses an evaluation model that analyzes large break loss-of-coolant accidents in pressurized water reactors using several computer codes. These codes separately calculate the system performance during the blowdown, refill, and reflooding phases of the transient. Multiple codes are used, in part, because a single code has been unable to effectively model the transition from blowdown to reflood, particularly in the downcomer region where high steam velocities do not allow the injected emergency core cooling (ECC) liquid to penetrate and begin to refill the vessel lower plenum until after the end of blowdown. BWNT is developing a method using the RELAP5/MOD2-B&W computer code that can correctly predict the liquid draindown behavior in the downcomer during the late blowdown and refill phases. Benchmarks of this method have been performed against Upper Plenum Test Facility (UPTF) data for ECC liquid penetration and valves using both cold leg and downcomer ECC injection. The use of this new method in plant applications should result in the calculation of a shorter refill period, leading to lower peak clad temperature predictions and increased core peaking. This paper identifies changes made to the RELAP/MOD2-B&W code to improve its predictive capabilities with respect to the data obtained in the UPTF tests.

  5. Analyzing the loss of coolant accident in PWR nuclear reactors with elevation change in cold leg by RELAP5/MOD3.2 system code

    International Nuclear Information System (INIS)

    Kheshtpaz, H.; Alison, C.

    2006-01-01

    As, the Russian designed VVER-1000 reactor of the Bushehr Nuclear Power Plant by taking into account the change from German technology to that of Russian technology, and with the design of elevation change in the cold legs has been developed; therefore safety assessment of these systems for loss of coolant accident in elevation change in the cold legs and comparison results for non change elevation in the cold legs for a typical reactor (normal design of nuclear reactors) is the main important factor to be considered for the safe operation. In this article, the main objective is the simulation of the loss of coolant accident scenario by the RELAP5/MOD3.2 code in two different cases; first, the elevation change in the cold legs, and the second, non change in it. After comparing and analyzing these two code calculations the results have been generalized for a new design feature of Bushehr reactor. The design and simulation of the elevation change in the cold legs process with RELAP5/MOD3.2 code for PWR reactor is performed for the first time in the country, where it is introducing several important results in this respect

  6. Re-assessment of RELAP/SCDAPSIM/MOD3.X using historical integral experiments

    Energy Technology Data Exchange (ETDEWEB)

    Allison, Chris M.; Hohorst, Judith K. [Innovative Systems Software, Ammon, ID (United States)

    2017-10-15

    The RELAP/SCDAPSIM code, designed to predict the behaviour of reactor systems during normal and accident conditions, is being developed by Innovative Systems Software (ISS) as part of the international SCDAP Development and Training Program (STDP). The ISS developed RELAP/SCDAPSIM uses the publicly available SCDAP/RELAP5 models and correlations developed by the US Nuclear Regulatory Commission in combination with proprietary features developed by ISS and STDP members. Experimental versions contain improved models for LWRs including improved SCDAP models and correlations. This paper summarises and describes the new models that were incorporated into the experimental versions of RELAP/SCDAPSIM along with the extensive assessment and verification activities that are currently underway at ISS and various universities and institutes around the world along with examples of thee assessment results.

  7. Latest developments for a computer aided thermohydraulic network

    International Nuclear Information System (INIS)

    Alemberti, A.; Graziosi, G.; Mini, G.; Susco, M.

    1999-01-01

    Thermohydraulic networks are I-D systems characterized by a small number of basic components (pumps, valves, heat exchangers, etc) connected by pipes and limited spatially by a defined number of boundary conditions (tanks, atmosphere, etc). The network system is simulated by the well known computer program RELAPS/mod3. Information concerning the network geometry component behaviour, initial and boundary conditions are usually supplied to the RELAPS code using an ASCII input file by means of 'input cards'. CATNET (Computer Aided Thermalhydraulic NETwork) is a graphically user interface that, under specific user guidelines which completely define its range of applicability, permits a very high level of standardization and simplification of the RELAPS/mod3 input deck development process as well as of the output processing. The characteristics of the components (pipes, valves, pumps etc), defining the network system can be entered through CATNET. The CATNET interface is provided by special functions to compute form losses in the most typical bending and branching configurations. When the input of all system components is ready, CATNET is able to generate the RELAPS/mod3 input file. Finally, by means of CATNET, the RELAPS/mod3 code can be run and its output results can be transformed to an intuitive display form. The paper presents an example of application of the CATNET interface as well as the latest developments which greatly simplified the work of the users and allowed to reduce the possibility of input errors. (authors)

  8. Assessment of RELAP5-3D copyright using data from two-dimensional RPI flow tests

    International Nuclear Information System (INIS)

    Davis, C.B.

    1998-01-01

    The capability of the RELAP5-3D copyright computer code to perform multi-dimensional thermal-hydraulic analysis was assessed using data from steady-state flow tests conducted at Rensselaer Polytechnic Institute (RPI). The RPI data were taken in a two-dimensional test section in a low-pressure air/water loop. The test section consisted of a thin vertical channel that simulated a two-dimensional slice through the core of a pressurized water reactor. Single-phase and two-phase flows were supplied to the test section in an asymmetric manner to generate a two-dimensional flow field. A traversing gamma densitometer was used to measure void fraction at many locations in the test section. High speed photographs provided information on the flow patterns and flow regimes. The RPI test section was modeled using the multi-dimensional component in RELAP5-3D Version BF06. Calculations of three RPI experiments were performed. The flow regimes predicted by the base code were in poor agreement with those observed in the tests. The two-phase regions were observed to be in the bubbly and slug flow regimes in the test. However, nearly all of the junctions in the horizontal direction were calculated to be in the stratified flow regime because of the relatively low velocities in that direction. As a result, the void fraction predictions were also in poor agreement with the measured values. Significantly improved results were obtained in sensitivity calculations with a modified version of the code that prevented the horizontal junctions from entering the stratified flow regime. These results indicate that the code's logic in the determination of flow regimes in a multi-dimensional component must be improved. The results of the sensitivity calculations also indicate that RELAP5-3D will provide a significant multi-dimensional hydraulic analysis capability once the flow regime prediction is improved

  9. Assessment study of RELAP5/MOD2, CYCLE 36. 04 based on spray start-up test for DOEL-4

    Energy Technology Data Exchange (ETDEWEB)

    Moeyaert, P.; Stubbe, E.

    1989-07-01

    This report presents an assessment study for the code RELAP-5 MOD-2 based on a pressurizer spray start-up test of the Doel-4 power plant. Doel-4 is a three loop WESTINGHOUSE PWR plant ordered by the EBES utility with a nominal power rating of 1000 MWe and equipped with preheater type E steam generators. A large series of commissioning tests are normally performed on new plants, of which the so called pressurizer spray and heater test (SU-PR-01) was performed on February 2nd 1985. TRACTEBEL, being the Architect-Engineer for this plant was closely involved with all start-up tests and was responsible for the final approval of the tests.

  10. Evaluation and assessment of reflooding models in RELAP5/Mod2.5 and RELAP5/Mod3 codes using Lehigh University and PSI-Neptun bundle experimental data

    Energy Technology Data Exchange (ETDEWEB)

    Sencar, M.; Aksan, N. [Paul Scherrer Institute, Villigen (Switzerland)

    1995-09-01

    An extensive analysis and assessment work on reflooding models of RELAP5/Mod2.5 and, RELAP5/Mod3/v5m5 and RELAP/Mod3/v7j have been performed. Experimental data from LehighUniversityv. and PSI-NEPTUN bundle reflooding experiments have been used for the assessment, since both of these tests cover a broad range of initial conditions. Within the range of these initial conditions, it was tried to identify their separate impacts on the calculated results. A total of six Lehigh University reflooding bundle tests and two PSI-NEPTUN tests with bounding initial conditions are selected for the analysis. Detailed nodalisation studies both for hydraulic and conduction heat transfer were done. On the basis of the results obtained from these cases, a base nodalisation scheme was established. All the other analysis work was performed by using this base nodalisation. RELAP5/Mod2.5 results do not change with renodalisation but RELAP5/Mod3 results are more sensitive to renodalisation. The results of RELAP5/Mod2.5 versions show very large deviations from the used experimental data. These results indicate that some of the phenomenology of the events occurring during the reflooding could not be identified. In the paper, detailed discussions on the main reasons of the deviations from the experimental data will be presented. Since, the results and findings of this study are meant to be a developmental aid, some recommendations have been drawn and some of these have already been implemented at PSI with promising results.

  11. Assessment of the Radiation Enclosure Models in SPACE and RELAP5 with GOTA Test 27

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T. B.; Lee, G. W.; Choi, T. S. [KEPCO, Daejeon (Korea, Republic of)

    2016-05-15

    SPACE (Safety and Performance Analysis Code) for nuclear power plant has been developed to calculate the transient thermal-hydraulic response of PWRs that can contain multiple types of fluids. Without explaining 3-D effects such as the change of fuel rod/guide tube thermal behavior as a result of the radiation heat transfer, the 1-D code could predict an unrealistically high peak clad temperature. A useful function to simulate the wall-to-wall radiation heat transfer is implemented in the SPACE and RELAP5 codes. This paper discusses the assessment results of the radiation enclosure model of SPACE and RELAP5. The capability of handling wall-to-wall radiation problem of the SPACE and the RELAP5 codes has been evaluated using the experimental data from the GOTA test facility. At the top of the bundle, the maximum errors of SPACE and RELAP5 are less than 1.6% and 2.3%, respectively. As noted, there is a small discrepancy between the calculated results and experimental data except for the predictions near the top of the test section. The SPACE code is based on the version 2.16 distributed by KHNP. In order to perform the simulation of the GOTA test 27, it was necessary to modify the SPACE code. There was the subroutine for an input process corresponding to the radiation model, the inp{sub c}heck function of the RadEncData Class, contained in a vulnerable algorithm to figure out the reciprocity rule of the view factor.

  12. RELAP4/MOD6 reflood heat transfer and data comparison

    International Nuclear Information System (INIS)

    Nelson, R.A.; Sullivan, L.H.

    1981-01-01

    This discussion of RELAP4/MOD6 will be limited to the reflood heat transfer models and evaluation of these models by comparison of calculation with results from three reflood experiments. The discussion of the model includes the heat transfer surface concept, the heat transfer correlations, the superheat model and the entrainment model which presents both the two-phase heat transfer and hydraulic models. In the discussion of the reflood heat transfer, the mathematical concept of a multidimensional surface is used to represent the heat flux of a given heat transfer correlation or correlations dependent upon such variables as quality, wall superheat and flux. This concept has been used to investigate the characteristics of the correlations, which are discusssed in detail, and the way they are applied to the two-phase mixture. Of primary importance in the reflood core heat transfer is the consideration of thermal nonequilibrium between the phases and the liquid entrainment, and its distribution up the core. Results obtained to date show the heat transfer and hydraulics to be closely coupled. Comparison of the RELAP4/MOD6 reflood calculations with the data from the forced feed FLECHT and gravity feed FLECHT-SET and Semiscale reflood experiments indicates that the heat transfer and hydraulic models are operational and yield good results

  13. Assessment and improvement of condensation models in RELAP5/MOD3.2

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ki Yong; Park, Hyun Sik; Kim, Sang Jae; No, Hee Chen [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-12-31

    The condensation models in the standard RELAP5/MOD3.2 code are assessed and improved based on the database, which is constructed from the previous experimental data on various condensation phenomena. The default model of the laminar film condensation in RELAP5/MOD3.2 does not give any reliable predictions, and its alternative model always predicts higher values than the experimental data. Therefore, it is needed to develop a new correlation based on the experimental data of various operating ranges in the constructed database. The Shah correlation, which is used to calculate the turbulent film condensation heat transfer coefficients in the standard RELAP5/MOD3.2, well predicts the experimental data in the database. The horizontally stratified condensation model of RELAP5/MOD3.2 overpredicts both cocurrent and countercurrent experimental data. The correlation proposed by H.J.Kim predicts the database relatively well compared with that of RELAP6/MOD3.2. The RELAP5/MOD3.2 model should use the liquid velocity for the calculation of the liquid Reynolds number and be modified to consider the effects of the gas velocity and the film thickness. 2 refs., 5 figs., 1 tab. (Author)

  14. Assessment and improvement of condensation models in RELAP5/MOD3.2

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ki Yong; Park, Hyun Sik; Kim, Sang Jae; No, Hee Chen [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1997-12-31

    The condensation models in the standard RELAP5/MOD3.2 code are assessed and improved based on the database, which is constructed from the previous experimental data on various condensation phenomena. The default model of the laminar film condensation in RELAP5/MOD3.2 does not give any reliable predictions, and its alternative model always predicts higher values than the experimental data. Therefore, it is needed to develop a new correlation based on the experimental data of various operating ranges in the constructed database. The Shah correlation, which is used to calculate the turbulent film condensation heat transfer coefficients in the standard RELAP5/MOD3.2, well predicts the experimental data in the database. The horizontally stratified condensation model of RELAP5/MOD3.2 overpredicts both cocurrent and countercurrent experimental data. The correlation proposed by H.J.Kim predicts the database relatively well compared with that of RELAP6/MOD3.2. The RELAP5/MOD3.2 model should use the liquid velocity for the calculation of the liquid Reynolds number and be modified to consider the effects of the gas velocity and the film thickness. 2 refs., 5 figs., 1 tab. (Author)

  15. Computation programs for the thermofluidodynamic transient analysis in the containment system following a LOCA

    International Nuclear Information System (INIS)

    Gorlandi, A.; Mazzini, M.; Oriolo, F.

    1979-01-01

    This works briefly describes the features of the computation codes available at the Istituto di Impianti Nucleari of the Pisa University for the analysis of the thermofluidodynamic transient in the containment system of a nuclear power plant following a LOCA (RELAP 4/MOD.S, COMPARE, FUMO and CONTEMPT-LT/026). More details are contained in the Annex. Particular attention has been devoted to the opportunity to study, through the computation codes, the effects of the sub division of a full pressure containment system

  16. NPP Krsko containment environmental conditions during postulated accident

    International Nuclear Information System (INIS)

    Kozaric, M.; Cavlina, N.; Spalj, S.

    1989-01-01

    This paper presents NPP Krsko containment pressure and temperature increase during Loss of Coolant Accident (LOCA) and Main Steam Line Break (MSLB). Containment environmental condition calculation was performed by CONTEMPT4/MOD4 computer code. Design accident calculations were performed by RELAP4/MOD6 and RELAP5/MOD1 computer codes. Calculational abilities and application methodology of these codes are presented. The CONTEMPT code is described in more detail. The containment pressure and temperature time distribution are presented as well. (author)

  17. Solving linear systems in FLICA-4, thermohydraulic code for 3-D transient computations

    International Nuclear Information System (INIS)

    Allaire, G.

    1995-01-01

    FLICA-4 is a computer code, developed at the CEA (France), devoted to steady state and transient thermal-hydraulic analysis of nuclear reactor cores, for small size problems (around 100 mesh cells) as well as for large ones (more than 100000), on, either standard workstations or vector super-computers. As for time implicit codes, the largest time and memory consuming part of FLICA-4 is the routine dedicated to solve the linear system (the size of which is of the order of the number of cells). Therefore, the efficiency of the code is crucially influenced by the optimization of the algorithms used in assembling and solving linear systems: direct methods as the Gauss (or LU) decomposition for moderate size problems, iterative methods as the preconditioned conjugate gradient for large problems. 6 figs., 13 refs

  18. Evaluation of the computer code system RADHEAT-V4 by analysing benchmark problems on radiation shielding

    International Nuclear Information System (INIS)

    Sakamoto, Yukio; Naito, Yoshitaka

    1990-11-01

    A computer code system RADHEAT-V4 has been developed for safety evaluation on radiation shielding of nuclear fuel facilities. To evaluate the performance of the code system, 18 benchmark problem were selected and analysed. Evaluated radiations are neutron and gamma-ray. Benchmark problems consist of penetration, streaming and skyshine. The computed results show more accurate than those by the Sn codes ANISN and DOT3.5 or the Monte Carlo code MORSE. Big core memory and many times I/O are, however, required for RADHEAT-V4. (author)

  19. Blowdown heat transfer surface in RELAP4/MOD6

    International Nuclear Information System (INIS)

    Nelson, R.A.; Sullivan, L.H.

    1978-01-01

    New heat transfer correlations for both PWR and BWR blowdowns have been implemented in the RELAP4/MOD6 program. The concept of a multidimensional surface is introduced with the heat flux from a given heat transfer correlation or correlations depicted as a mathematical surface that is dependent upon quality, wall superheat, mass flow and pressure. The heat transfer logic has been modularized to facilitate replacing boiling curves for future correlation data comparisons and investigations. To determine the validity of the blowdown surface, comparison has been performed using data from the Semiscale experimental facility. (author)

  20. Spent fuel pool thermal-hydraulic analysis using RELAP5-3D

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, M. C.; Fernandes, G.H.N.; Costa, A.L.; Pereira, F.; Pereira, C., E-mail: marc5663@gmail.com, E-mail: ghnfernandes@pq.cnpq.br, E-mail: claubia@nuclear.ufmg.br, E-mail: antonella@nuclear.ufmg.br [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    In order to analyze the thermo-hydraulic behavior of spent fuel pools, and taking as reference a hypothetic PWR nuclear plant, a model of RELAP-3D for a spent fuel pool has been built. This model has been used to simulate a loss of coolant in SPF. This study focuses on the loss of coolant flow accident in spent fuel storage pool which is modelled by using RELAP5-3D code to observe the coolant level reduction and fuel uncovery because of decay heat generation of the spent fuel in the pool. The results have been compared with the available data. The developed model demonstrated that the RELAP5-3D is capable of reproduce the thermal behavior of SPF in a transient scenario. (author)

  1. Mars 2.2 code manual: input requirements

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Lee, Won Jae; Jeong, Jae Jun; Lee, Young Jin; Hwang, Moon Kyu; Kim, Kyung Doo; Lee, Seung Wook; Bae, Sung Won

    2003-07-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This input manual provides a complete list of input required to run MARS. The manual is divided largely into two parts, namely, the one-dimensional part and the multi-dimensional part. The inputs for auxiliary parts such as minor edit requests and graph formatting inputs are shared by the two parts and as such mixed input is possible. The overall structure of the input is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS. MARS development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  2. MARS code manual volume II: input requirements

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Kim, Kyung Doo; Bae, Sung Won; Jeong, Jae Jun; Lee, Seung Wook; Hwang, Moon Kyu

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This input manual provides a complete list of input required to run MARS. The manual is divided largely into two parts, namely, the one-dimensional part and the multi-dimensional part. The inputs for auxiliary parts such as minor edit requests and graph formatting inputs are shared by the two parts and as such mixed input is possible. The overall structure of the input is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  3. RELAP5 kinetics model development for the Advanced Test Reactor

    International Nuclear Information System (INIS)

    Judd, J.L.; Terry, W.K.

    1990-01-01

    A point-kinetics model of the Advanced Test Reactor has been developed for the RELAP5 code. Reactivity feedback parameters were calculated by a three-dimensional analysis with the PDQ neutron diffusion code. Analyses of several hypothetical reactivity insertion events by the new model and two earlier models are discussed. 3 refs., 10 figs., 6 tabs

  4. Development, validation and application of multi-point kinetics model in RELAP5 for analysis of asymmetric nuclear transients

    Energy Technology Data Exchange (ETDEWEB)

    Pradhan, Santosh K., E-mail: santosh@aerb.gov.in [Nuclear Safety Analysis Division, Atomic Energy Regulatory Board, Mumbai 400094 (India); Obaidurrahman, K. [Nuclear Safety Analysis Division, Atomic Energy Regulatory Board, Mumbai 400094 (India); Iyer, Kannan N. [Department of Mechanical Engineering, IIT Bombay, Mumbai 400076 (India); Gaikwad, Avinash J. [Nuclear Safety Analysis Division, Atomic Energy Regulatory Board, Mumbai 400094 (India)

    2016-04-15

    Highlights: • A multi-point kinetics model is developed for RELAP5 system thermal hydraulics code. • Model is validated against extensive 3D kinetics code. • RELAP5 multi-point kinetics formulation is used to investigate critical break for LOCA in PHWR. - Abstract: Point kinetics approach in system code RELAP5 limits its use for many of the reactivity induced transients, which involve asymmetric core behaviour. Development of fully coupled 3D core kinetics code with system thermal-hydraulics is the ultimate requirement in this regard; however coupling and validation of 3D kinetics module with system code is cumbersome and it also requires access to source code. An intermediate approach with multi-point kinetics is appropriate and relatively easy to implement for analysis of several asymmetric transients for large cores. Multi-point kinetics formulation is based on dividing the entire core into several regions and solving ODEs describing kinetics in each region. These regions are interconnected by spatial coupling coefficients which are estimated from diffusion theory approximation. This model offers an advantage that associated ordinary differential equations (ODEs) governing multi-point kinetics formulation can be solved using numerical methods to the desired level of accuracy and thus allows formulation based on user defined control variables, i.e., without disturbing the source code and hence also avoiding associated coupling issues. Euler's method has been used in the present formulation to solve several coupled ODEs internally at each time step. The results have been verified against inbuilt point-kinetics models of RELAP5 and validated against 3D kinetics code TRIKIN. The model was used to identify the critical break in RIH of a typical large PHWR core. The neutronic asymmetry produced in the core due to the system induced transient was effectively handled by the multi-point kinetics model overcoming the limitation of in-built point kinetics model

  5. User manual for version 4.3 of the Tripoli-4 Monte-Carlo method particle transport computer code

    International Nuclear Information System (INIS)

    Both, J.P.; Mazzolo, A.; Peneliau, Y.; Petit, O.; Roesslinger, B.

    2003-01-01

    This manual relates to Version 4.3 TRIPOLI-4 code. TRIPOLI-4 is a computer code simulating the transport of neutrons, photons, electrons and positrons. It can be used for radiation shielding calculations (long-distance propagation with flux attenuation in non-multiplying media) and neutronic calculations (fissile medium, criticality or sub-criticality basis). This makes it possible to calculate k eff (for criticality), flux, currents, reaction rates and multi-group cross-sections. TRIPOLI-4 is a three-dimensional code that uses the Monte-Carlo method. It allows for point-wise description in terms of energy of cross-sections and multi-group homogenized cross-sections and features two modes of geometrical representation: surface and combinatorial. The code uses cross-section libraries in ENDF/B format (such as JEF2-2, ENDF/B-VI and JENDL) for point-wise description cross-sections in APOTRIM format (from the APOLLO2 code) or a format specific to TRIPOLI-4 for multi-group description. (authors)

  6. Presentation of RELAP5 results on the personal computer

    International Nuclear Information System (INIS)

    Salamun, I.; Stritar, A.

    1991-01-01

    DrALF is a program for graphical presentation of RELAP5 results. Results may be displayed in two different forms, as graphs with different zoom capabilities and as drawings or nodalizations with different variables displayed on a background picture. (author)

  7. Demonstration of fully coupled simplified extended station black-out accident simulation with RELAP-7

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Anders, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, Richard [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-10-01

    The RELAP-7 code is the next generation nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). The RELAP-7 code develop-ment effort started in October of 2011 and by the end of the second development year, a number of physical components with simplified two phase flow capability have been de-veloped to support the simplified boiling water reactor (BWR) extended station blackout (SBO) analyses. The demonstration case includes the major components for the primary system of a BWR, as well as the safety system components for the safety relief valve (SRV), the reactor core isolation cooling (RCIC) system, and the wet well. Three scenar-ios for the SBO simulations have been considered. Since RELAP-7 is not a severe acci-dent analysis code, the simulation stops when fuel clad temperature reaches damage point. Scenario I represents an extreme station blackout accident without any external cooling and cooling water injection. The system pressure is controlled by automatically releasing steam through SRVs. Scenario II includes the RCIC system but without SRV. The RCIC system is fully coupled with the reactor primary system and all the major components are dynamically simulated. The third scenario includes both the RCIC system and the SRV to provide a more realistic simulation. This paper will describe the major models and dis-cuss the results for the three scenarios. The RELAP-7 simulations for the three simplified SBO scenarios show the importance of dynamically simulating the SRVs, the RCIC sys-tem, and the wet well system to the reactor safety during extended SBO accidents.

  8. Analysis, by Relap5 code, of boron dilution phenomena in a Small Break Loca Transient, performed in PKL III E 2.2 test

    International Nuclear Information System (INIS)

    Rizzo, G.; Vella, G.

    2007-01-01

    The present work is finalized to investigate the E2.2 thermal-hydraulics transient of the PKL III facility, which is a scaled reproduction of a typical German PWR, operated by FRAMATOME-ANP in Erlangen, Germany, within the framework of an international cooperation (OECD/SETH project). The main purpose of the project is to study boron dilution events in Pressurized Water Reactors and to contribute to the assessment of thermal-hydraulic system codes like Relap5. The experimental test PKL III E2.2 investigates the behavior of a typical PWR after a Small Break Loss Of Coolant Accident (SB-LOCA) in a cold leg and an immediate injection of borated water in two cold legs. The main purpose of this work is to simulate the PKL III test facility and particularly its experimental transient by Relap5 system code. The adopted nodalization, already available at Department of Nuclear Engineering (DIN), has been reviewed and applied with an accurate analysis of the experimental test parameters. The main result relies in a good agreement of calculated data with experimental measures for a number of main important variables. (author)

  9. RELAP/SCDAPSIM/MOD4.0 modification for transient accident scenario of Test Blanket Modules in ITER involving helium flows into heavy liquid metal

    Energy Technology Data Exchange (ETDEWEB)

    Freixa, J.; Pérez, M.; Mas de les Valls, E.; Batet, L.; Sandeep, T.; Chaudhari, V.; Reventós, F.

    2015-07-01

    The Institute for Plasma Research (IPR), India, is currently involved in the design and development of its Test Blanket Module (TBM) for testing in ITER (International Thermo nuclear Experimental Reactor). The Indian TBM concept is a Lead-Lithium cooled Ceramic Breeder (LLCB), which utilizes lead-lithium eutectic alloy (LLE) as tritium breeder, neutron multiplier and coolant. The first wall facing the plasma is cooled by helium gas. In preparation of the regulatory safety files of ITER-TBM, a number of off-normal event sequences have been postulated. Thermal hydraulic safety analyses of the TBM system will be carried out with the system code RELAP/SCDAPSIM/MOD4.0 which was initially designed to predict the behavior of light water reactor systems during normal and accidental conditions. In order to analyze some of the postulated off-normal events, there is the need to simulate the mixing of Helium and Lead-Lithium fluids. The Technical University of Catalonia is cooperating with IPR to implement the necessary changes in the code to allow for the mixing of helium and liquid metal. In the present study, the RELAP/SCDAPSIM/MOD4 two-phase flow 6-equations structure has been modified to allow for the mixture of LLE in the liquid phase with dry Helium in the gas phase. Practically obtaining a two-fluid 6-equation model where each fluid is simulated with a set of energy, mass and momentum balance equations. A preliminary flow regime map for LLE and helium flow has been developed on the basis of numerical simulations with the OpenFOAM CFD toolkit. The new code modifications have been verified for vertical and horizontal configurations. (Author)

  10. Framatome's experience in implementing and runnig RELAP5 MOD1

    Energy Technology Data Exchange (ETDEWEB)

    Truong, T.X.; Rousset, P.

    1984-12-01

    Implementation of RELAP MOD1 on Framatome's computer began in 1982, when we were working with the electrical power research institute on a safety and relief valve test program. It has been carried out in two stages: a first implementation on the CISI CYBER 740 computer; a transfer of files and a second on implemented our own CYBER 835 computer. The RELAP5 version currently implemented and used in Framatome is the cycle 19 standard version, no modification has been made yet, though some changes in data output files are intended.

  11. RELAP/MOD3.2 Assessment Using an 11% Upper Plenum Break Experiment in the PSB Facility

    Energy Technology Data Exchange (ETDEWEB)

    Bayless, P.D.

    2003-01-17

    The RELAP/MOD3.2 computer code has been assessed using an 11% upper plenum break experiment in the PSB test facility at the Electrogorsk Research and Engineering Center. This work was performed as part of the U.S. Department of Energy's International Nuclear Safety Program, and is part of the effort addressing the capability of the RELAP5/MOD3.2 code to model transients in Soviet-designed reactors. Designated VVER Standard Problem PSBV1, the test addressed several important phenomena related to VVER behavior that the code needs to simulate well. The code was judged to reasonably model the phenomena of two-phase flow natural circulation in the primary coolant system, asymmetric loop behavior, leak flow, loop seal clearance in the cold legs, heat transfer in a covered core, heat transfer in a partially covered core, pressurizer thermal-hydraulics, and integral system effects. The code was judged to be in minimal agreement with the experiment data for the mixture level and entrainment in the core, leading to a user recommendation to assess the sensitivity of transient calculations to the interphase drag modeling in the core. No judgments were made for the phenomena of phase separation without mixture level formation, mixture level and entrainment in the steam generators, pool formation in the upper plenum, or flow stratification in horizontal pipes because either the phenomenon did not occur in the test or there were insufficient measurements to characterize the behavior.

  12. RELAP/MOD3.2 Assessment Using an 11% Upper Plenum Break Experiment in the PSB Facility

    International Nuclear Information System (INIS)

    Bayless, P.D.

    2003-01-01

    The RELAP/MOD3.2 computer code has been assessed using an 11% upper plenum break experiment in the PSB test facility at the Electrogorsk Research and Engineering Center. This work was performed as part of the U.S. Department of Energy's International Nuclear Safety Program, and is part of the effort addressing the capability of the RELAP5/MOD3.2 code to model transients in Soviet-designed reactors. Designated VVER Standard Problem PSBV1, the test addressed several important phenomena related to VVER behavior that the code needs to simulate well. The code was judged to reasonably model the phenomena of two-phase flow natural circulation in the primary coolant system, asymmetric loop behavior, leak flow, loop seal clearance in the cold legs, heat transfer in a covered core, heat transfer in a partially covered core, pressurizer thermal-hydraulics, and integral system effects. The code was judged to be in minimal agreement with the experiment data for the mixture level and entrainment in the core, leading to a user recommendation to assess the sensitivity of transient calculations to the interphase drag modeling in the core. No judgments were made for the phenomena of phase separation without mixture level formation, mixture level and entrainment in the steam generators, pool formation in the upper plenum, or flow stratification in horizontal pipes because either the phenomenon did not occur in the test or there were insufficient measurements to characterize the behavior

  13. Sensitive analysis and modifications to reflood-related constitutive models of RELAP5

    International Nuclear Information System (INIS)

    Li Dong; Liu Xiaojing; Yang Yanhua

    2014-01-01

    Previous system code calculation reveals that the cladding temperature is underestimated and quench front appears too early during reflood process. To find out the parameters shows important effect on the results, sensitive analysis is performed on parameters of constitutive physical models. Based on the phenomenological and theoretical analysis, four parameters are selected: wall to vapor film boiling heat transfer coefficient, wall to liquid film boiling heat transfer coefficient, dry wall interfacial friction coefficient and minimum droplet diameter. In order to improve the reflood simulation ability of RELAP5 code, the film boiling heat transfer model and dry wall interfacial friction model which are corresponding models of those influential parameters are studied. Modifications have been made and installed into RELAP5 code. Six tests of FEBA are simulated by RELAP5 to study the predictability of reflood-related physical models. A dispersed flow film boiling heat transfer (DFFB) model is applied when void fraction is above 0.9. And a factor is multiplied to the post-CHF drag coefficient to fit the experiment better. Finally, the six FEBA tests are calculated again so as to assess the modifications. Better results are obtained which prove the advantage of the modified models. (author)

  14. RELAP5: Applications to high fidelity simulation

    International Nuclear Information System (INIS)

    Johnsen, G.W.; Chen, Y.S.

    1988-01-01

    RELAP5 is a pressurized water reactor system transient simulation code for use in nuclear power plant safety analysis. The latest version, MOD2, may be used to simulate and study a wide variety of abnormal events, including loss-of-coolant accidents, operational transients, and transients in which the entire secondary system must be modeled. In this paper, a basic overview of the code is given, its assessment and application illustrated, and progress toward its use as a high fidelity simulator described. 7 refs., 7 figs

  15. RELAP5 simulation for one and two-phase natural circulation phenomenon

    International Nuclear Information System (INIS)

    Sabundjian, Gaiane; Andrade, Delvonei Alves de; Umbehaun, Pedro Ernesto; Torres, Walmir Maximo; Castro, Alfredo Jose Alvim de; Braz Filho, Francisco A.; Borges, Eduardo Madeira; Damy. Osvaldo Luiz Almeida; Torres, Eduardo

    2007-01-01

    The objective of this paper is to study the natural circulation phenomenon in one and two-phase regime. There has been a crescent interest in the scientific community in the study of the natural circulation. New generation of compact nuclear reactors uses the natural circulation for residual heat removal in case of accident or shutdown. For this study, the modeling and the simulation of the experimental circuit is performed with the RELAP5 code. The experimental circuit is mounted in the Chemical Engineering Department of the University of Sao Paulo. It is presented in this work the theoretical/experimental comparison for one and two-phase flow. These results will be stored in a database to validate RELAP5 calculations. This work was also used to training some users of RELAP5 from IEAv. (author)

  16. PHISICS/RELAP5-3D Adaptive Time-Step Method Demonstrated for the HTTR LOFC#1 Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Robin Ivey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Balestra, Paolo [Univ. of Rome (Italy); Strydom, Gerhard [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-05-01

    A collaborative effort between Japan Atomic Energy Agency (JAEA) and Idaho National Laboratory (INL) as part of the Civil Nuclear Energy Working Group is underway to model the high temperature engineering test reactor (HTTR) loss of forced cooling (LOFC) transient that was performed in December 2010. The coupled version of RELAP5-3D, a thermal fluids code, and PHISICS, a neutronics code, were used to model the transient. The focus of this report is to summarize the changes made to the PHISICS-RELAP5-3D code for implementing an adaptive time step methodology into the code for the first time, and to test it using the full HTTR PHISICS/RELAP5-3D model developed by JAEA and INL and the LOFC simulation. Various adaptive schemes are available based on flux or power convergence criteria that allow significantly larger time steps to be taken by the neutronics module. The report includes a description of the HTTR and the associated PHISICS/RELAP5-3D model test results as well as the University of Rome sub-contractor report documenting the adaptive time step theory and methodology implemented in PHISICS/RELAP5-3D. Two versions of the HTTR model were tested using 8 and 26 energy groups. It was found that most of the new adaptive methods lead to significant improvements in the LOFC simulation time required without significant accuracy penalties in the prediction of the fission power and the fuel temperature. In the best performing 8 group model scenarios, a LOFC simulation of 20 hours could be completed in real-time, or even less than real-time, compared with the previous version of the code that completed the same transient 3-8 times slower than real-time. A few of the user choice combinations between the methodologies available and the tolerance settings did however result in unacceptably high errors or insignificant gains in simulation time. The study is concluded with recommendations on which methods to use for this HTTR model. An important caveat is that these findings

  17. Role of RELAP/SCDAPSIM in Nuclear Safety

    International Nuclear Information System (INIS)

    Allison, C.M.; Hohorst, J.K.

    2010-01-01

    The RELAP/SCDAPSIM code, designed to predict the behaviour of reactor systems during normal and accident conditions, is being developed as part of the international SCDAP Development and Training Program (SDTP). SDTP consists of nearly 60 organizations in 28 countries supporting the development of technology, software, and training materials for the nuclear industry. The program members and licensed software users include universities, research organizations, regulatory organizations, vendors, and utilities located in Europe, Asia, Latin America, and the United States. Innovative Systems Software (ISS) is the administrator for the program. RELAP/SCDAPSIM is used by program members and licensed users to support a variety of activities. The paper provides a brief review of some of the more important activities including the analysis of research reactors and Nuclear Power Plants, design and analysis of experiments, and training

  18. Analysis of a total flow blockage of a Fuel Assembly in a typical MTR Research Reactor by RELAP5/MOD3.3

    International Nuclear Information System (INIS)

    Adorni, M.; Salah, A.B.; Di Maro, B.; Pierro, F.; D'Auria, F.; Hamidouche, T.

    2004-01-01

    The lack of full understanding of complex mechanisms connected with the interaction between thermal-hydraulics and neutronics still challenge the design and the operation of nuclear reactors by the adoption of conservative safety limits. The recent availability of powerful computer and computational techniques together with the continuing increase in operational experience imposes the revisiting of those areas and eventually the identification of design/safety requirements that can be relaxed [1]. Currently, the enlarged commercial exploitation of nuclear Research Reactors (RR) has increased the consideration to their corresponding safety issues. Almost all of the safety analyses have so far been performed using conservative computational tools [2]. Nowadays, the application of Best-Estimate (BE) methods constitutes a real necessity in order to increase their commercial productivity. In this framework, an attempt is made to apply the BE technique to perform a safety evaluation under research reactors operational conditions. In fact, this technique has been largely verified and validated for power reactors using coupled system thermal-hydraulic and three-dimensional neutron kinetics [1]. For this purpose, as typical representative of research reactors, the IAEA 10 MW MTR Research Reactors problem [3] is considered. The system thermal-hydraulic RELAP5 [4] code was developed to simulate transient scenarios in Power reactors such PWR, BWR, VVER, etc. However, only limited work was performed to access the applicability of the code to Research Reactors operating conditions (low pressure, mass flow rates, power, etc) [5]. Previous works performed in this field are reported in [5], [6] and [7]. In this framework, total and partial blockage of a single Fuel Assembly cooling channel are investigated. As a first attempt the calculations are performed by applying the BE thermal-hydraulic system code RELAP5 alone using its point kinetic model to derive the instantaneous core

  19. Thermal-hydraulic code selection for modular high temperature gas-cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    Komen, E M.J.; Bogaard, J.P.A. van den

    1995-06-01

    In order to study the transient thermal-hydraulic system behaviour of modular high temperature gas-cooled reactors, the thermal-hydraulic computer codes RELAP5, MELCOR, THATCH, MORECA, and VSOP are considered at the Netherlands Energy Research Foundation ECN. This report presents the selection of the most appropriate codes. To cover the range of relevant accidents, a suite of three codes is recommended for analyses of HTR-M and MHTGR reactors. (orig.).

  20. Improving containment mass and energy releases for CONTEMPT-LT/028 TU with RELAP5/MOD3

    International Nuclear Information System (INIS)

    DaSilva, H.C.; Choe, W.G.

    1996-01-01

    In order to obtain boundary conditions for RELAP5/MOD3 best estimate (BE) large break (LB) loss-of-coolant accident (LOCA) calculations, it is necessary to utilize a separate containment analysis code CONTEMPT-LT/028 TU, which in turn accepts mass and energy releases from the RELAP5/MOD3 calculation. When these boundary conditions are obtained, they are observed to be significantly lower than those reported in FSAR containment analyses. This motivates the present study, where RELAP5/MOD3 mass and energy releases are generated using the same assumptions listed in the FSAR containment calculations. Then CONTEMPT-LT/028 TU pressures and temperatures calculated with both sets of mass and energy releases are compared. It is seen that those obtained with the RELAP5/MOD3 input are still significantly lower, indicating a level of conservatism in the FSAR mass and energy releases that is even above that explicitly listed and also incorporated into the RELAP5/MOD3 calculation. An important conclusion from this finding is that Environmental Qualification (EQ) issues requiring containment re-analyses are likely to be easily resolved if new mass and energy releases are calculated with state-of-the-art LOCA codes modeling the entire reactor coolant system, even when conservative assumptions are incorporated

  1. Analysis of the OECD-LOFT International Standard Problem 31 using SCDAP/RELAP5/MOD3

    International Nuclear Information System (INIS)

    Hohorst, J.K.; Allison, C.M.

    1992-01-01

    The CORA-13 bundle heating and melting experiment performed at the Kernforechungszentrum, Karlaruhe, (KfK) was analyzed at the Idaho National Engineering Laboratory (INEL) using SCDAP/RELAP5/MOD3. This analysis was part of a systematic assessment of SCDAP/RELAP5/MOD3 for the US Nuclear Regulatory Commission to (a) evaluate the variances between calculated and observed behavior, (b) identify outstanding modeling deficiencies, and (c) to evaluate the impact of ongoing modeling improvements. A brief discussion of the CORA-13 experiment including a description of the facility, important test conditions, and comparisons with other CORA experimental conditions and results is provided in this report. This report describes the results of the SCDAP/RELAPS/MOD3 analysis including a description of the SCDAP/RELAPS model of the facility, base case results, sensitivity results, and a comparison with other SCDAP/RELAP5/MOD3 code-to-data comparisons

  2. TMI-2 analysis using SCDAP/RELAP5/MOD3.1

    International Nuclear Information System (INIS)

    Hohorst, J.K.; Polkinghorne, S.T.; Siefken, L.J.; Allison, C.M.; Dobbe, C.A.

    1994-11-01

    SCDAP/RELAP5/MOD3.1, an integrated thermal hydraulic analysis code developed primarily to simulate severe accidents in nuclear power plants, was used to predict the progression of core damage during the TMI-2 accident. The version of the code used for the TMI-2 analysis described in this paper includes models to predict core heatup, core geometry changes, and the relocation of molten core debris to the lower plenum of the reactor vessel. This paper describes the TMI-2 input model, initial conditions, boundary conditions, and the results from the best-estimate simulation of Phases 1 to 4 of the TMI-2 accident as well as the results from several sensitivity calculations

  3. Comparison between UMSICHT water hammer experiments and calculations using RELAP5/MOD3.3

    International Nuclear Information System (INIS)

    Messing, Ralf

    2008-01-01

    Water hammer phenomena regularly occur in piping systems of nuclear power plants, e.g. after the rapid closure of valves. As the loads are usually several times higher than during normal operation pipe rupture is possible and therefore the integrity of the nuclear power plant can be endangered. In recent years extensive studies have been performed to assess the capabilities of the widely-used transient thermohydraulic system codes like RELAP5 for the simulation of water hammers and pressure surges in piping systems. The parameters affecting the results of such simulations are on the one side related to the numerical method, in particular the grid step size Δx and time step size Δt, and on the other hand to the models for present physical effects like the fluid-structure-interaction (FSI), unsteady friction or the release of dissolved air. In many studies experimental data obtained at the Fraunhofer Institute UMSICHT at Oberhausen/Germany has been used for code validation. In a vast campaign reliable data has been measured under varying boundary conditions for pressure surges in a pipe after a fast valve closure. Details of the experimental set-up are described in /1/ and /2/. Tiselj and Petelin /3/ provided theoretical background on the properties of the numerical scheme used by RELAP5 and Tiselj and Cerne /4/ highlighted the behavior at very small time steps. Kaliatka and al. /5/ investigated the influence of the grid step size and the time step size in RELAP5 on pressure transients obtained in UMSICHT experiments. Neuhaus and Dudlik /2/,/6/ studied the effects of fluidstructure- interaction, unsteady friction and degassing of dissolved air in tape-water filled pipes on pressure surges. They compared their numerical results again with experimental data from the UMSICHT test facility and observed a significant impact of all three parameters on the pressure-surge amplitudes and frequency. Barten and al. /15/ performed calculations of experiment 329 of the UMSICHT

  4. Safety analysis code input automation using the Nuclear Plant Data Bank

    International Nuclear Information System (INIS)

    Kopp, H.; Leung, J.; Tajbakhsh, A.; Viles, F.

    1985-01-01

    The Nuclear Plant Data Bank (NPDB) is a computer-based system that organizes a nuclear power plant's technical data, providing mechanisms for data storage, retrieval, and computer-aided engineering analysis. It has the specific objective to describe thermohydraulic systems in order to support: rapid information retrieval and display, and thermohydraulic analysis modeling. The Nuclear Plant Data Bank (NPBD) system fully automates the storage and analysis based on this data. The system combines the benefits of a structured data base system and computer-aided modeling with links to large scale codes for engineering analysis. Emphasis on a friendly and very graphically oriented user interface facilitates both initial use and longer term efficiency. Specific features are: organization and storage of thermohydraulic data items, ease in locating specific data items, graphical and tabular display capabilities, interactive model construction, organization and display of model input parameters, input deck construction for TRAC and RELAP analysis programs, and traceability of plant data, user model assumptions, and codes used in the input deck construction process. The major accomplishments of this past year were the development of a RELAP model generation capability and the development of a CRAY version of the code

  5. Assessment of selected TRAC and RELAP5 calculations for Oconee-1 pressurized thermal shock study

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Pu, J.; Saha, P.; Jo, J.

    1984-11-01

    Several Oconee-1 overcooling transients that were computed by LANL and INEL using the latest versions of TRAC-PF1 and RELAPS/MOD1.5 codes have been reviewed by BNL. Three of these transients were selected for detailed review as they either had the potential of challenging the integrity of the pressure vessel or highlighted the effect of code differences. These are: (1) Main Steam Line Break (MSLB); (2) All Turbine Bypass Valves Stuck Open; and (3) 2-Inch Small Break LOCA. Both codes were reasonably successful in modeling these transients. However, there were differences in the code results even though the specified scenarios were exactly the same for two transients (MSLB and Small Break LOCA). This report compares the code results and explains the possible reasons for these differences. Recommendations have been made regarding which result seems more reasonable for a specific transient

  6. ATLAS Cold Leg Top Slot Break Analysis using RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Haejung; Lee, Sang Ik; Park, Ju-Hyun; Choi, Tong-Soo [KEPCO NF, Daejeon (Korea, Republic of)

    2016-10-15

    U.S. Nuclear Regulatory Commission (US-NRC) has been reviewing the design certification application for APR1400 submitted by Korea Electric Power Corporation (KEPCO). The main concern about cold leg top slot break is that cladding temperature might be increased by core uncover due to four loop seal reformation following flooding of safety injection water. An integral effect test for cold leg top slot break was performed by KAERI (Korea Atomic Energy Research Institute) using ATLAS (Advanced Thermal-Hydraulic Test Loop for Accident Simulation), which is a scaled down experimental facility for APR1400. In this study, RELAP5/MOD3.3/Patch04 is assessed by experimental result of ATLAS cold leg top slot break. Also, thermal hydraulic phenomena by four loop seals reformation is observed by RELAP5 result. The RELAP5/MOD3.3/Patch04 is assessed by the experimental result of ATLAS cold leg top slot break. The top slot break is described by offtake model, and the mass flow rate is fairly well estimated. The RELAP5 well predicts the correlation between general trend and four loop seal reformation. The pressure of the core region and the cladding temperature tends to increase during four loop seal reformation due to steam path blockage on four loop seals. It is presumed that the code cannot estimate two phase phenomena by loop seal clearing as same as experiments. In terms of cladding temperature, loop seal reformation due to loop seal elevation of APR1400 does not need to be the issue, since the void fraction at the active top core is maintained over 0.4.

  7. RELAP-5/MOD 3.2 Assessment Using an 11% Upper Plenum Break Experiment in the PSB Facility

    Energy Technology Data Exchange (ETDEWEB)

    Paul D. Bayless

    2003-01-01

    The RELAP/MOD3.2 computer code has been assessed using an 11% upper plenum break experiment in the PSB test facility at the Electrogorsk Research and Engineering Center. This work was performed as part of the U.S. Department of Energy's International Nuclear Safety Program, and is part of the effort addressing the capability of the RELAP5/MOD3.2 code to model transients in Soviet-designed reactors. Designated VVER Standard Problem PSBV1, the test addressed several important phenomena related to VVER behavior that the code needs to simulate well. The code was judged to reasonably model the phenomena of two-phase flow natural circulation in the primary coolant system, asymmetric loop behavior, leak flow, loop seal clearance in the cold legs, heat transfer in a covered core, heat transfer in a partially covered core, pressurizer thermal-hydraulics, and integral system effects. The code was judged to be in minimal agreement with the experiment data for the mixture level and entrainment in the core, leading to a user recommendation to assess the sensitivity of transient calculations to the interphase drag modeling in the core. No judgments were made for the phenomena of phase separation without mixture level formation, mixture level and entrainment in the steam generators, pool formation in the upper plenum, or flow stratification in horizontal pipes because either the phenomenon did not occur in the test or there were insufficient measurements to characterize the behavior.

  8. User manual for version 4.3 of the Tripoli-4 Monte-Carlo method particle transport computer code; Notice d'utilisation du code Tripoli-4, version 4.3: code de transport de particules par la methode de Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Both, J.P.; Mazzolo, A.; Peneliau, Y.; Petit, O.; Roesslinger, B

    2003-07-01

    This manual relates to Version 4.3 TRIPOLI-4 code. TRIPOLI-4 is a computer code simulating the transport of neutrons, photons, electrons and positrons. It can be used for radiation shielding calculations (long-distance propagation with flux attenuation in non-multiplying media) and neutronic calculations (fissile medium, criticality or sub-criticality basis). This makes it possible to calculate k{sub eff} (for criticality), flux, currents, reaction rates and multi-group cross-sections. TRIPOLI-4 is a three-dimensional code that uses the Monte-Carlo method. It allows for point-wise description in terms of energy of cross-sections and multi-group homogenized cross-sections and features two modes of geometrical representation: surface and combinatorial. The code uses cross-section libraries in ENDF/B format (such as JEF2-2, ENDF/B-VI and JENDL) for point-wise description cross-sections in APOTRIM format (from the APOLLO2 code) or a format specific to TRIPOLI-4 for multi-group description. (authors)

  9. Post test analysis of TEPSS tests -P2-, -P3-, -P5- and -P7- using the system code RELAP5/MOD 3.2

    International Nuclear Information System (INIS)

    Luebbesmeyer, D.

    2000-01-01

    For the PANDA-Test-Facility (TEPSS configuration) post-test calculations and analyses have been performed for experiment -P2- (Early Start), -P3- (PCC start up), -P5- (Symmetric case, Two PCCs only) and -P7- (Severe Accident). Post test calculations have been performed with the system code RELAP5/Mod 3.2 using two different nodalization of the PANDA facility namely a basis nodalization and a much reduced one. The general trend of the calculations can be summarised: RELAP5/Mod3.2 calculated the general trends of the experiments sufficiently accurate; Using the reduced nodalization the results seem to be slightly more accurate than for the basic nodalization; On the other hand, calculations based on the reduced nodalization are not significantly faster than those with basic nodalization; The mass error is in the order of 200 to 900 kg. (author)

  10. RELAP5 two-phase fluid model and numerical scheme for economic LWR system simulation

    International Nuclear Information System (INIS)

    Ransom, V.H.; Wagner, R.J.; Trapp, J.A.

    1981-01-01

    The RELAP5 two-phase fluid model and the associated numerical scheme are summarized. The experience accrued in development of a fast running light water reactor system transient analysis code is reviewed and example of the code application are given

  11. Application of RELAP5-3D code for thermal analysis of the ADS reactor core; Aplicação do código RELAP5-3D para análise térmica do núcleo de um reator ADS

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Gustavo Henrique Nazareno

    2018-04-01

    Nuclear power is essential to supply global energy demand. Therefore, in order to use nuclear fuel more efficiently, more efficient nuclear reactors technologies researches have been intensified, such as hybrid systems, composed of particle accelerators coupled into nuclear reactors. In order to add knowledge to such studies, an innovative reactor design was considered where the RELAP5-3D thermal-hydraulic analysis code was used to perform a thermal analysis of the core, either in stationary operation or in situations transitory. The addition of new kind of coolants, such as, liquid salts, among them Flibe, lead, lead-bismuth, sodium, lithium-bismuth and lithium-lead was an important advance in this version of the code, making possible to do the thermal simulation of reactors that use these types of coolants. The reactor, object of study in this work, is an innovative reactor, due to its ability to operate in association with an Accelerator Driven System (ADS), considered a predecessor system of the next generation of nuclear reactors (GEN IV). The reactor selected was the MYRRHA (Multi-purpose Hybrid Research Reactor for High tech Applications) due to the availability of data to perform the simulation. In the modeling of the reactor with the code RELAP5-3D, the core was simulated using nodules with 1, 7, 15 and 51 thermohydraulic channels and eutectic lead-bismuth (LBE) as coolant. The parameters, such as, pressure, mass flow and coolant and heat structure temperature were analyzed. In addition, the thermal behavior of the core was evaluated by varying the type of coolant (sodium) in substitution for the LBE of the original design using the model with 7 thermohydraulic channels. The results of the steady-state calculations were compared with data from the literature and the proposed models were verified certifying the ability of the RELAP5-3D code to simulate this innovative reactor. After this step, it was analysed cases of transients with loss of coolant flow

  12. Analysis of the VVER-1000 coolant transient benchmark phase 1 with the code system RELAP5/PARCS

    International Nuclear Information System (INIS)

    Victor Hugo Sanchez Espinoza

    2005-01-01

    Full text of publication follows: As part of the reactor dynamics activities of FZK/IRS, the qualification of best-estimate coupled code systems for reactor safety evaluations is a key step toward improving their prediction capability and acceptability. The VVER-1000 Coolant Transient Benchmark Phase 1 represents an excellent opportunity to validate the simulation capability of the coupled code system RELAP5/PACRS regarding both the thermal hydraulic plant response (RELAP5) using measured data obtained during commissioning tests at the Kozloduy nuclear power plant unit 6 and the neutron kinetics models of PARCS for hexagonal geometries. The Phase 1 is devoted to the analysis of the switching on of one main coolant pump while the other three pumps are in operation. It includes the following exercises: (a) investigation of the integral plant response using a best-estimate thermal hydraulic system code with a point kinetics model (b) analysis of the core response for given initial and transient thermal hydraulic boundary conditions using a coupled code system with 3D-neutron kinetics model and (c) investigation of the integral plant response using a best-estimate coupled code system with 3D-neutron kinetics. Already before the test, complex flow conditions exist within the RPV e.g. coolant mixing in the upper plenum caused by the reverse flow through the loop-3 with the stopped pump. The test is initiated by switching on the main coolant pump of loop-3 that leads to a reversal of the flow through the respective piping. After about 13 s the mass flow rate through this loop reaches values comparable with the one of the other loops. During this time period, the increased primary coolant flow causes a reduction of the core averaged coolant temperature and thus an increase of the core power. Later on, the power stabilizes at a level higher than the initial power. In this analysis, special attention is paid on the prediction of the spatial asymmetrical core cooling during

  13. Computation of a BWR Turbine Trip with CATHARE-CRONOS2-FLICA4 Coupled Codes

    International Nuclear Information System (INIS)

    Mignot, G.; Royer, E.; Rameau, B.; Todorova, N.

    2004-01-01

    The CEA/DEN modeling and computation results with the CATHARE, CRONOS2, and FLICA4 codes of the Organisation for Economic Co-operation and Development boiling water reactor turbine trip benchmark are presented. The first exercise of the benchmark to model the whole reactor thermal hydraulics with specified power has been performed with the CATHARE system code. Exercise 2, devoted to core thermal-hydraulic neutronic analysis with provided boundary conditions and neutronic cross sections, has been carried out with the CRONOS2 and FLICA4 codes. Finally, exercise 3, combining system thermal hydraulics and core three-dimensional thermal-hydraulics-neutronics, was computed with the three coupled codes: CATHARE, CRONOS2, and FLICA4.Our one-dimensional thermal-hydraulic reactor computation agrees well with the benchmark reference data and demonstrates the capacities of CATHARE to model a turbine trip transient. Coupled three-dimensional thermal-hydraulic and neutronic analysis displays a high sensitivity of the power peak to the core thermal-hydraulic model. The use of at least 100 channels is recommended to achieve reasonable results for integral and local parameters. Deviations between experimental data and exercise 3 results are discussed: timing of events, core pressure drop, and neutronic model. Finally, analysis of extreme scenarios as sensitivity studies on the transient to assess the effect of the scram, the bypass relief valve, and the steam relief valves is presented

  14. Application of a generalized interface module to the coupling of PARCS with both RELAPS and TRAC-M

    International Nuclear Information System (INIS)

    Barber, D.A.; Wang, W.; Miller, R.M.; Downar, T.J.; Joo, H.G.; Mousseau, V.A.; Ebert, D.E.

    1999-01-01

    In an effort to more easily assess various combinations of 3-D neutronic/thermal-hydraulic codes, the USNRC has sponsored the development of a generalized interface module for the coupling of any thermal-hydraulics code to any spatial kinetics code. In this design, the thermal-hydraulics, general interface, and spatial kinetics codes function independently and utilize the Parallel Virtual Machine (PVM) software to manage inter-process communication. Using this interface, the USNRC version of the 3D neutron kinetics code, PARCS, has been coupled to the USNRC system analysis codes RELAP5 and TRAC-M. RELAP5/PARCS assessment results are presented for an OECD/NEA main steam line break benchmark problem. The assessment of TRAC-M/PARCS has only recently been initiated; nonetheless, the capabilities of the coupled code are presented for the OECD/NEA main steam line break benchmark problem

  15. Role of RELAP/SCDAPSIM in Nuclear Safety

    Directory of Open Access Journals (Sweden)

    C. M. Allison

    2010-01-01

    Full Text Available The RELAP/SCDAPSIM code, designed to predict the behaviour of reactor systems during normal and accident conditions, is being developed as part of the international SCDAP Development and Training Program (SDTP. SDTP consists of nearly 60 organizations in 28 countries supporting the development of technology, software, and training materials for the nuclear industry. The program members and licensed software users include universities, research organizations, regulatory organizations, vendors, and utilities located in Europe, Asia, Latin America, and the United States. Innovative Systems Software (ISS is the administrator for the program. RELAP/SCDAPSIM is used by program members and licensed users to support a variety of activities. The paper provides a brief review of some of the more important activities including the analysis of research reactors and Nuclear Power Plants, design and analysis of experiments, and training.

  16. Plant balance model for RELAP/SCDAPSIM; Modelo de balance de planta para RELAP/SCDAPSIM

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza M, R. [Consultor independiente, Ciudad de Mexico (Mexico); Filio L, C. [IPN, Escuela Superior de Fisica y Matematicas, Av. IPN s/n, 07738 Ciudad de Mexico (Mexico); Araiza M, E.; Ortiz V, J., E-mail: rafael_mendozam_esfm@live.com.mx [ININ, Carretera Mexico-Touca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2017-09-15

    In this work we developed an integral model for a nuclear power plant and have a more general picture of what happens in both the Nuclear Steam Supply System (NSSS) and the Balance of Plant (Bop) system during abnormal events that are presented in operation. RELAP/SCDAPSIM (RSS) is a computation code of the type of best estimate that can simulate the transient and accident behavior of a nuclear installation. The development of a Bop model for RSS can result in the simulation of transients such as turbine trip due to loss of vacuum in the main steam condenser. This work shows the development of models of the Bop main components for the RSS code, such as the set of high and low pressure turbines, as well as their steam extractions to the feed water heaters, the main steam condenser, a feed water heater and the condensate and water feed pumps. This new model of the Plant Balance system was then coupled to the NSSS model that is already in RSS. First, results of the steady state with this new integral model are show, to later show results of the transients simulation: 1) turbine trip due to loss of vacuum in the main steam condenser; 2) loss of condensate pumps; and 3) failure of the feed water heater. (Author)

  17. Improvement and validation of the wall heat transfer package of RELAP5/MOD3.3

    International Nuclear Information System (INIS)

    Wu, Pan; Xiong, Xiaofei; Shan, Jianqiang; Gou, Junli; Zhang, Bin; Zhang, Bo

    2016-01-01

    Highlights: • A new heat transfer package has been developed. • It has been incorporated into RELAP5/MOD3.3 to verify its advantages. • The results of modified code were compared with available experimental data. • The results showed that higher prediction accuracy was achieved. - Abstract: The process of energy transfer from heat structure to control volume is determined by the wall-to-fluid heat transfer package, which is crucial for nuclear reactor safety analysis codes. The current logic for selection of heat transfer modes of RELAP5/MOD3.3 code is too complex and may result in incorrect heat transfer mode judgment. Also, the narrow application scope of film boiling heat transfer correlations may result in large errors in film boiling region which is of paramount importance for the predicted peak clad temperatures during hypothetical LB-LOCAs in PWRs. In this study, a new heat transfer package has been developed and incorporated into the RELAP5/MOD3.3 code. Differing from the original package, the modified one consists of twelve heat transfer modes and proposes a new logic for selection of heat transfer modes. For each mode, the models in the existing safety analysis codes and the leading models in literature have been reviewed in order to determine the best model which can easily be applicable to the RELAP5/MOD3.3 code. Particularly (1) a new package of heat transfer correlations are produced; (2) a new logic for selection of film boiling and transition boiling heat transfer modes is proposed which use minimum film boiling temperature and critical heat flux temperature as distinguished points. The modified code has been validated by comparing the analysis results with available experimental data from tube post dryout experiments and loss-of-fluid test (LOFT) facility. The calculation results showed that the improved package could better predict the experimental phenomena with higher prediction accuracy.

  18. Improvement and validation of the wall heat transfer package of RELAP5/MOD3.3

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Pan; Xiong, Xiaofei; Shan, Jianqiang, E-mail: jqshan@mail.xjtu.edu.cn; Gou, Junli; Zhang, Bin; Zhang, Bo

    2016-12-15

    Highlights: • A new heat transfer package has been developed. • It has been incorporated into RELAP5/MOD3.3 to verify its advantages. • The results of modified code were compared with available experimental data. • The results showed that higher prediction accuracy was achieved. - Abstract: The process of energy transfer from heat structure to control volume is determined by the wall-to-fluid heat transfer package, which is crucial for nuclear reactor safety analysis codes. The current logic for selection of heat transfer modes of RELAP5/MOD3.3 code is too complex and may result in incorrect heat transfer mode judgment. Also, the narrow application scope of film boiling heat transfer correlations may result in large errors in film boiling region which is of paramount importance for the predicted peak clad temperatures during hypothetical LB-LOCAs in PWRs. In this study, a new heat transfer package has been developed and incorporated into the RELAP5/MOD3.3 code. Differing from the original package, the modified one consists of twelve heat transfer modes and proposes a new logic for selection of heat transfer modes. For each mode, the models in the existing safety analysis codes and the leading models in literature have been reviewed in order to determine the best model which can easily be applicable to the RELAP5/MOD3.3 code. Particularly (1) a new package of heat transfer correlations are produced; (2) a new logic for selection of film boiling and transition boiling heat transfer modes is proposed which use minimum film boiling temperature and critical heat flux temperature as distinguished points. The modified code has been validated by comparing the analysis results with available experimental data from tube post dryout experiments and loss-of-fluid test (LOFT) facility. The calculation results showed that the improved package could better predict the experimental phenomena with higher prediction accuracy.

  19. Post-test sensitivity analysis of OECD/CSNI ISP42 panda experiment by Relap5 code

    International Nuclear Information System (INIS)

    Zanocco, P.; D'Auria, F.; Galassi, G.M.

    2001-01-01

    The present document deals with Relap5/Mod3.2 analysis of the International Standard Problem (ISP-42) exercise performed in PANDA facility on April 21-22, 1998. PANDA is installed at PSI (Paul Scherrer Institute). PANDA is a large-scale thermal-hydraulic test facility suitable for the simulation of passive containment for Advanced Light Water Reactors (ALWR). The work focuses phase A of the ISP-42 experiment, including the break in the main steam line, and the Passive Containment Cooling System Start-Up. The objective is to investigate the start-up phenomenology of passive cooling system when steam is injected into cold vessel filled with air and to observe the resulting system behavior. A detailed nodalization was set-up at the University of Pisa, in order to model 3-D flow paths with a 1-D code. The comparison between pre-test predictions and experimental data is discussed. Overall time behavior is reasonably well predicted, showing a rather good and robust overall code behavior in the simulation of the global test scenario. The results of a preliminary post-test analysis are discussed, including the comparison with the experimental data. (authors)

  20. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (parallelization). Progress report fiscal 1996

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hideo; Kawai, Wataru; Nemoto, Toshiyuki [Fujitsu Ltd., Tokyo (Japan); and others

    1997-12-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the parallelization. In this parallelization part, the parallelization of 2-Dimensional relativistic electromagnetic particle code EM2D, Cylindrical Direct Numerical Simulation code CYLDNS and molecular dynamics code for simulating radiation damages in diamond crystals DGR are described. In the vectorization part, the vectorization of two and three dimensional discrete ordinates simulation code DORT-TORT, gas dynamics analysis code FLOWGR and relativistic Boltzmann-Uehling-Uhlenbeck simulation code RBUU are described. And then, in the porting part, the porting of reactor safety analysis code RELAP5/MOD3.2 and RELAP5/MOD3.2.1.2, nuclear data processing system NJOY and 2-D multigroup discrete ordinate transport code TWOTRAN-II are described. And also, a survey for the porting of command-driven interactive data analysis plotting program IPLOT are described. (author)

  1. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (vectorization). Progress report fiscal 1996

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Toshiyuki; Kawai, Wataru [Fujitsu Ltd., Tokyo (Japan); Kawasaki, Nobuo [and others

    1997-12-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the vectorization. In this vectorization part, the vectorization of two and three dimensional discrete ordinates simulation code DORT-TORT, gas dynamics analysis code FLOWGR and relativistic Boltzmann-Uehling-Uhlenbeck simulation code RBUU are described. In the parallelization part, the parallelization of 2-Dimensional relativistic electromagnetic particle code EM2D, Cylindrical Direct Numerical Simulation code CYLDNS and molecular dynamics code for simulating radiation damages in diamond crystals DGR are described. And then, in the porting part, the porting of reactor safety analysis code RELAP5/MOD3.2 and RELAP5/MOD3.2.1.2, nuclear data processing system NJOY and 2-D multigroup discrete ordinate transport code TWOTRAN-II are described. And also, a survey for the porting of command-driven interactive data analysis plotting program IPLOT are described. (author)

  2. Vectorization, parallelization and porting of nuclear codes on the VPP500 system (porting). Progress report fiscal 1996

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Toshiyuki [Fujitsu Ltd., Tokyo (Japan); Kawasaki, Nobuo; Tanabe, Hidenobu [and others

    1998-01-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. These results are reported in 3 parts, i.e., the vectorization part, the parallelization part and the porting part. In this report, we describe the porting. In this porting part, the porting of reactor safety analysis code RELAP5/MOD3.2 and RELAP5/MOD3.2.1.2, nuclear data processing system NJOY and 2-D multigroup discrete ordinate transport code TWOTRAN-II are described. And also, a survey for the porting of command-driven interactive data analysis plotting program IPLOT are described. In the parallelization part, the parallelization of 2-Dimensional relativistic electromagnetic particle code EM2D, Cylindrical Direct Numerical Simulation code CYLDNS and molecular dynamics code for simulating radiation damages in diamond crystals DGR are described. And then, in the vectorization part, the vectorization of two and three dimensional discrete ordinates simulation code DORT-TORT, gas dynamics analysis code FLOWGR and relativistic Boltzmann-Uehling-Uhlenbeck simulation code RBUU are described. (author)

  3. Thermal hydraulic and neutron kinetic simulation of the Angra 2 reactor using a RELAP5/PARCS coupled model

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Patricia A.L.; Costa, Antonella L.; Hamers, Adolfo R.; Pereira, Claubia; Rodrigues, Thiago D.A.; Mantecon, Javier G.; Veloso, Maria A.F., E-mail: patricialire@yahoo.com.br, E-mail: antonella@nuclear.ufmg.br, E-mail: adolforomerohamers@hotmail.com, E-mail: claubia@nuclear.ufmg.br, E-mail: thiagodanielbh@gmail.com, E-mail: mantecon1987@gmail.com, E-mail: dora@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Instituto Nacional de Ciencias e Tecnologia de Reatores Nucleares Inovadores (INCT/CNPq), Belo Horizonte (Brazil); Miro, Rafael; Verdu, Gumersindo, E-mail: rmiro@iqn.upv.es, E-mail: gverdu@iqn.upv.es [Universidad Politecnica de Valencia (Spain). Departamento de Ingenieria Quimica y Nuclear

    2015-07-01

    The computational advances observed in the last two decades have been provided direct impact on the researches related to nuclear simulations, which use several types of computer codes, including coupled between them, allowing representing with very accuracy the behavior of nuclear plants. Studies of complex scenarios in nuclear reactors have been improved by the use of thermal-hydraulic (TH) and neutron kinetics (NK) coupled codes. This technique consists in incorporating three-dimensional (3D) neutron modeling of the reactor core into codes, mainly to simulate transients that involve asymmetric core spatial power distributions and strong feedback effects between neutronics and reactor thermal-hydraulics. Therefore, this work presents preliminary results of TH RELAP5 and the NK PARCS calculations applied to model of the Angra 2 reactor. The WIMSD-5B code has been used to generate the macroscopic cross sections used in the NK code. The results obtained are satisfactory and represent important part of the development of this methodology. The next step is to couple the codes. (author)

  4. Development of a nuclear power plant system analysis code

    International Nuclear Information System (INIS)

    Sim, Suk K.; Jeong, J. J.; Ha, K. S.; Moon, S. K.; Park, J. W.; Yang, S. K.; Song, C. H.; Chun, S. Y.; Kim, H. C.; Chung, B. D.; Lee, W. J.; Kwon, T. S.

    1997-07-01

    During the period of this study, TASS 1.0 code has been prepared for the non-LOCA licensing and reload safety analyses of the Westinghouse and the Korean Standard Nuclear Power Plants (KSNPP) type reactors operating in Korea. TASS-NPA also has been developed for a real time simulation of the Kori-3/4 transients using on-line graphical interactions. TASS 2.0 code has been further developed to timely apply the TASS 2.0 code for the design certification of the KNGR. The COBRA/RELAP5 code, a multi-dimensional best estimate system code, has been developed by integrating the realistic three-dimensional reactor vessel model with the RELAP5 /MOD3.2 code, a one-dimensional system code. Also, a 3D turbulent two-phase flow analysis code, FEMOTH-TF, has been developed using finite element technique to analyze local thermal hydraulic phenomena in support of the detailed design analysis for the development of the advanced reactors. (author). 84 refs., 27 tabs., 83 figs

  5. Dispersed flow film boiling: An investigation of the possibility to improve the models implemented in the NRC computer codes for the reflooding phase of the LOCA

    International Nuclear Information System (INIS)

    Andreani, M.; Yadigaroglu, G.; Paul Scherrer Inst.

    1992-08-01

    Dispersed Flow Film Boiling is the heat transfer regime that occurs at high void fractions in a heated channel. The way this heat transfer mode is modelled in the NRC computer codes (RELAP5 and TRAC) and the validity of the assumptions and empirical correlations used is discussed. An extensive review of the theoretical and experimental work related with heat transfer to highly dispersed mixtures reveals the basic deficiencies of these models: the investigation refers mostly to the typical conditions of low rate bottom reflooding, since the simulation of this physical situation by the computer codes has often showed poor results. The alternative models that are available in the literature are reviewed, and their merits and limits are highlighted. The modifications that could improve the physics of the models implemented in the codes are identified

  6. A generic semi-implicit coupling methodology for use in RELAP5-3Dcopyright

    International Nuclear Information System (INIS)

    Aumiller, D.L.; Tomlinson, E.T.; Weaver, W.L.

    2000-01-01

    A generic semi-implicit coupling methodology has been developed and implemented in the RELAP5-3Dcopyright computer program. This methodology allows RELAP5-3Dcopyright to be used with other computer programs to perform integrated analyses of nuclear power reactor systems and related experimental facilities. The coupling methodology potentially allows different programs to be used to model different portions of the system. The programs are chosen based on their capability to model the phenomena that are important in the simulation in the various portions of the system being considered. The methodology was demonstrated using a test case in which the test geometry was divided into two parts each of which was solved as a RELAP5-3Dcopyright simulation. This test problem exercised all of the semi-implicit coupling features which were installed in RELAP5-3D0. The results of this verification test case show that the semi-implicit coupling methodology produces the same answer as the simulation of the test system as a single process

  7. Application of a generalized interface module to the coupling of PARCS with both RELAP5 and TRAC-M

    Energy Technology Data Exchange (ETDEWEB)

    Barber, D.A.; Wang, W. [SCIENTECH, Inc. (United States); Miller, R.M.; Downar, T.J. [Purdue Univ., West Lafayette, IN (United States); Joo, H.G. [Korean Atomic Energy Research Inst., Seoul (Korea, Republic of); Mousseau, V.A. [Los Alamos National Lab., NM (United States); Ebert, D.E. [Nuclear Regulatory Commission, Washington, DC (United States)

    1999-04-01

    In an effort to more easily assess various combinations of 3-D neutronic/thermal-hydraulic codes, the USNRC has sponsored the development of a generalized interface module for the coupling of any thermal-hydraulics code to any spatial kinetics code. In this design, the thermal-hydraulics, general interface, and spatial kinetics codes function independently and utilize the Parallel Virtual Machine (PVM) software to manage inter-process communication. Using this interface, the USNRC version of the 3D neutron kinetics code, PARCS, has been coupled to the USNRC system analysis codes RELAP5 and TRAC-M. RELAP5/PARCS assessment results are presented for an OECD/NEA main steam line break benchmark problem. The assessment of TRAC-M/PARCS has only recently been initiated; nonetheless, the capabilities of the coupled code are presented for the OECD/NEA main steam line break benchmark problem.

  8. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    International Nuclear Information System (INIS)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.; Rohatgi, U.S.

    1995-01-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba's Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations al these conditions were compared with the GIRAFFE data. The effects of PCCS cell nodings on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to ±5% of the data with a three-node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer in the presence of noncondensable gases with only a coarse mesh. The cell length term in the condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes

  9. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    International Nuclear Information System (INIS)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.

    1995-01-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba's Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to ±5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes

  10. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C. [and others

    1995-09-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba`s Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to {plus_minus}5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes.

  11. Aztheca Code

    International Nuclear Information System (INIS)

    Quezada G, S.; Espinosa P, G.; Centeno P, J.; Sanchez M, H.

    2017-09-01

    This paper presents the Aztheca code, which is formed by the mathematical models of neutron kinetics, power generation, heat transfer, core thermo-hydraulics, recirculation systems, dynamic pressure and level models and control system. The Aztheca code is validated with plant data, as well as with predictions from the manufacturer when the reactor operates in a stationary state. On the other hand, to demonstrate that the model is applicable during a transient, an event occurred in a nuclear power plant with a BWR reactor is selected. The plant data are compared with the results obtained with RELAP-5 and the Aztheca model. The results show that both RELAP-5 and the Aztheca code have the ability to adequately predict the behavior of the reactor. (Author)

  12. Development of an interactive model of the Laguna Verde nuclear power plant based on the RELAP/SCDAP code

    International Nuclear Information System (INIS)

    Salazar C, J.H.; Ramos P, J.C.; Salazar S, E.; Chavez M, C.

    2003-01-01

    The present work describes the development of an interactive model of the Nuclear power plant of Laguna Verde (CNLV) based on the RELAP/SCDAP nuclear code, and it incorporation to a classroom simulator. The functional prototype it allows to make evaluations for operational transients and postulates accidents, with capacitation purposes, training, analysis and design. It emphasizes on the methodology used to establish the inter activity. Such methodology, is based on a modular structure in the one that multiple processes can be executed in an independent way and where the generated information is stored in segments of shared memory (characteristic that allows the UNIX operating system) and sent to the different processes by means of communication routines developed in C programming language. The utility of the system is demonstrated by means of the use of interactive display graphics (mimic diagrams, pictorials and tendency graphics) for the simultaneous dynamic visualization of the variables more significant that involve to the pattern of a transitory event type (for example failure of the controller of feeding water in a BWR reactor). Near with the interactive module, it was developed a model of the reactor of the CNLV for the code of better estimation RELAP/SCDAP. Finally the evaluation of the model is described, where it is interpreted in general form the behavior of those main variables that describe the stationary state, corroborating that follow the same tendency that those reported in the FSAR (Final Safety Analysis Report) of the Laguna Verde plant. The obtained results allow to conclude that the made development was satisfactory and that it presents enormous advantages regarding the capacity and time of analysis when using tools of visualization in real time of execution. (Author)

  13. Modeling developments for the SAS4A and SASSYS computer codes

    International Nuclear Information System (INIS)

    Cahalan, J.E.; Wei, T.Y.C.

    1990-01-01

    The SAS4A and SASSYS computer codes are being developed at Argonne National Laboratory for transient analysis of liquid metal cooled reactors. The SAS4A code is designed to analyse severe loss-of-coolant flow and overpower accidents involving coolant boiling, Cladding failures, and fuel melting and relocation. Recent SAS4A modeling developments include extension of the coolant boiling model to treat sudden fission gas release upon pin failure, expansion of the DEFORM fuel behavior model to handle advanced cladding materials and metallic fuel, and addition of metallic fuel modeling capability to the PINACLE and LEVITATE fuel relocation models. The SASSYS code is intended for the analysis of operational and beyond-design-basis transients, and provides a detailed transient thermal and hydraulic simulation of the core, the primary and secondary coolant circuits, and the balance-of-plant, in addition to a detailed model of the plant control and protection systems. Recent SASSYS modeling developments have resulted in detailed representations of the balance of plant piping network and components, including steam generators, feedwater heaters and pumps, and the turbine. 12 refs., 2 tabs

  14. National autonomous university of Mexico RELAP/SCDAPSIM-based plant simulation and training applications to the Laguna Verde NPP

    International Nuclear Information System (INIS)

    Chavez-Mercado, C.; Hohorst, J.K.; Allison, C.M.

    2004-01-01

    The RELAP/SCDAPSIM code, designed to predict the behavior of reactor systems during normal and accident conditions, is being developed by Innovative Systems Software as part of the International SCDAP Development and Training Program (SDTP). This code is being used as the simulator engine for the National Autonomous University of Mexico's Simulation and Training Facility located at the Campus Morelos in Jiutepec, Mexico. This paper describes the RELAP/SCDAPSIM code, the Simulation and Training facility at the National Autonomous University of Mexico, and the application of the training system to the Laguna Verde Nuclear Power Plant located in the Mexican state of Veracruz. (author)

  15. Investigations of the VVER-1000 coolant transient benchmark phase 1 with the coupled code system RELAP5/PARCS

    International Nuclear Information System (INIS)

    Sanchez-Espinoza, Victor Hugo

    2008-07-01

    As part of the reactor dynamics activities of FZK/IRS, the qualification of best-estimate coupled code systems for reactor safety evaluations is a key step toward improving their prediction capability and acceptability. The VVER-1000 Coolant Transient Benchmark Phase 1 represents an excellent opportunity to validate the simulation capability of the coupled code system RELAP5/PACRS regarding both the thermal hydraulic plant response (RELAP5) using measured data obtained during commissioning tests at the Kozloduy nuclear power plant unit 6 and the neutron kinetics models of PARCS for hexagonal geometries. The Phase 1 is devoted to the analysis of the switching on of one main coolant pump while the other three pumps are in operation. It includes the following exercises: (a) investigation of the integral plant response using a best-estimate thermal hydraulic system code with a point kinetics model (b) analysis of the core response for given initial and transient thermal hydraulic boundary conditions using a coupled code system with 3D-neutron kinetics model and (c) investigation of the integral plant response using a best-estimate coupled code system with 3D-neutron kinetics. Already before the test, complex flow conditions exist within the RPV e.g. coolant mixing in the upper plenum caused by the reverse flow through the loop-3 with the stopped pump. The test is initiated by switching on the main coolant pump of loop-3 that leads to a reversal of the flow through the respective piping. After about 13 s the mass flow rate through this loop reaches values comparable with the one of the other loops. During this time period, the increased primary coolant flow causes a reduction of the core averaged coolant temperature and thus an increase of the core power. Later on, the power stabilizes at a level higher than the initial power. In this analysis, special attention is paid on the prediction of the spatial asymmetrical core cooling during the test and its effects on the

  16. Investigations of the VVER-1000 coolant transient benchmark phase 1 with the coupled code system RELAP5/PARCS

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Espinoza, Victor Hugo

    2008-07-15

    As part of the reactor dynamics activities of FZK/IRS, the qualification of best-estimate coupled code systems for reactor safety evaluations is a key step toward improving their prediction capability and acceptability. The VVER-1000 Coolant Transient Benchmark Phase 1 represents an excellent opportunity to validate the simulation capability of the coupled code system RELAP5/PACRS regarding both the thermal hydraulic plant response (RELAP5) using measured data obtained during commissioning tests at the Kozloduy nuclear power plant unit 6 and the neutron kinetics models of PARCS for hexagonal geometries. The Phase 1 is devoted to the analysis of the switching on of one main coolant pump while the other three pumps are in operation. It includes the following exercises: (a) investigation of the integral plant response using a best-estimate thermal hydraulic system code with a point kinetics model (b) analysis of the core response for given initial and transient thermal hydraulic boundary conditions using a coupled code system with 3D-neutron kinetics model and (c) investigation of the integral plant response using a best-estimate coupled code system with 3D-neutron kinetics. Already before the test, complex flow conditions exist within the RPV e.g. coolant mixing in the upper plenum caused by the reverse flow through the loop-3 with the stopped pump. The test is initiated by switching on the main coolant pump of loop-3 that leads to a reversal of the flow through the respective piping. After about 13 s the mass flow rate through this loop reaches values comparable with the one of the other loops. During this time period, the increased primary coolant flow causes a reduction of the core averaged coolant temperature and thus an increase of the core power. Later on, the power stabilizes at a level higher than the initial power. In this analysis, special attention is paid on the prediction of the spatial asymmetrical core cooling during the test and its effects on the

  17. An Update on Improvements to NiCE Support for RELAP-7

    Energy Technology Data Exchange (ETDEWEB)

    McCaskey, Alex [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wojtowicz, Anna [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Deyton, Jordan H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patterson, Taylor C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Billings, Jay Jay [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    The Multiphysics Object-Oriented Simulation Environment (MOOSE) is a framework that facilitates the development of applications that rely on finite-element analysis to solve a coupled, nonlinear system of partial differential equations. RELAP-7 represents an update to the venerable RELAP-5 simulator that is built upon this framework and attempts to model the balance-of-plant concerns in a full nuclear plant. This report details the continued support and integration of RELAP-7 and the NEAMS Integrated Computational Environment (NiCE). RELAP-7 is fully supported by the NiCE due to on-going work to tightly integrate NiCE with the MOOSE framework, and subsequently the applications built upon it. NiCE development throughout the first quarter of FY15 has focused on improvements, bug fixes, and feature additions to existing MOOSE-based application support. Specifically, this report will focus on improvements to the NiCE MOOSE Model Builder, the MOOSE application job launcher, and the 3D Nuclear Plant Viewer. This report also includes a comprehensive tutorial that guides RELAP-7 users through the basic NiCE workflow: from input generation and 3D Plant modeling, to massively parallel job launch and post-simulation data visualization.

  18. Development of a VBA macro-based spreadsheet application for RELAP5 data post-processing

    International Nuclear Information System (INIS)

    Belchior Junior, Antonio; Andrade, Delvonei A.; Sabundjian, Gaiane; Macedo, Luiz A.; Angelo, Gabriel; Torres, Walmir M.; Umbehaun, Pedro E.; Conti, Thadeu N.; Bruel, Renata N.

    2011-01-01

    During the use of thermal-hydraulic codes such as RELAP5, large amount of data has to be managed in order to prepare its input data and also to analyze the produced results. This work presents a helpful tool developed to make it easier to handle the RELAP5 output data file. The XTRIP application is an electronic spreadsheet that contains some programmed macros that should be used for post-processing the RELAP5 output file. It can directly read the RELAP5 restart-plot binary output file and, through a user-friendly interface, transient results can be chosen and exported directly into an electronic worksheet. The XTRIP program can also do some data unit conversion as well as export these data to other programs such as Wingraf, Grapher and COBRA, etc. The main features of the developed Excel Visual Basic for Application macro as well as an example of use are presented and discussed. (author)

  19. RELAP5/MOD3.2 investigation of reactor vessel YR line capabilities for primary side depressurization during the TLFW in VVER1000/V320

    International Nuclear Information System (INIS)

    Gencheva, Rositsa V.; Stefanova, Antoaneta E.; Groudev, Pavlin P.

    2005-01-01

    During the development of Symptom Based Emergency Operating Procedures (SB-EOPs) for VVER-1000/V320 units at Kozloduy Nuclear Power Plant (NPP), a number of analyses have been performed using the RELAP5/MOD3.2 computer code. One of them is 'Investigation of reactor vessel YR line capabilities for primary side depressurization during the Total Loss of Feed Water (TLFW)'. The main purpose of these calculations is to evaluate the capabilities of YR line located at the top of the reactor vessel for primary side depressurization to the set point of High Pressure Injection System (HPIS) actuation and the abilities for successful core cooling after Feed and Bleed procedure initiation. For the purpose of this, operator action with 'Reactor vessel off-gas valve - 0.032 m' opening has been investigated. RELAP5/MOD3.2 computer code has been used to simulate the TLFW transient in VVER-1000 NPP model. This model was developed at Institute for Nuclear Research and Nuclear Energy - Bulgarian Academy of Sciences (INRNE-BAS), Sofia, for analyses of operational occurrences, abnormal events, and design basis scenarios. The model provides a significant analytical capability for the specialists working in the field of NPP safety

  20. Code comparison results for the loft LP-FP-2 experiment

    International Nuclear Information System (INIS)

    Merilo, M.; Mecham, D.C.

    1991-01-01

    Computer code calculations are compared with thermal hydraulic and fission product release, transport, and deposition data obtained from the OECD-LOFT LP-FP-2 experiment. Except for the MAAP code, which is a fully integrated severe accident code, the thermalhydraulic and fission product behavior were calculated with different codes. Six organizations participated in the thermal hydraulic portion of the code comparison exercise. These calculations were performed with RELAP 5, SCDAP/RELAP 5, and MAAP. The comparisons show generally well developed capabilities to determine the thermal-hydraulic conditions during the early stages of a severe core damage accident. Four participants submitted detailed fission product behavior calculations. Except for MAAP, as stated previously, the fission product inventory, core damage, fission product release, transport and deposition were calculated independently with different codes. Much larger differences than observed for the thermalhydraulic comparison were evident. The fission product inventory calculations were generally in good agreement with each other. Large differences were observed for release fractions and amounts of deposition. Net release calculations from the primary system were generally accurate within a factor of two or three for the more important fission products

  1. Investigation of a two-phase nozzle flow and validation of several computer codes by the experimental data

    International Nuclear Information System (INIS)

    Kedziur, F.

    1980-03-01

    Stationary experiments with a convergent nozzle are performed in order to validate advanced two-phase computer codes, which find application in the blowdown-phase of a loss-of-coolant accident (LOCA). The steam/water flow presents a broad variety of initial conditions: The pressure varies between 2 and 13 MPa, the void fraction between 0 (subcooled) and about 80%, a great number of subcritical as well as critical experiments with different flow pattern is investigated. Additional air/water experiments serve for the separation of phase transition effects. The transient acceleration of the fluid in the LOCA-case is simulated by a local acceleration in the experiments. The layout of the nozzle and the applied measurement technique allow for a separate testing of physical models and the determination of empirical model parameters, respectively: In the four codes DUESE, DRIX-20, RELAP4/MOD6 and STRUYA the models - if they exist - for slip between the phases, thermodynamic non-equilibrium, pipe friction and critical mass flow rate are validated and criticised in comparison with the experimental data, and the corresponding model parameters are determined. The parameters essentially are a function of the void fraction. (orig.) [de

  2. RELAP5 model to simulate the thermal-hydraulic effects of grid spacers and cladding rupture during reflood

    Energy Technology Data Exchange (ETDEWEB)

    Nithianandan, C.K.; Klingenfus, J.A.; Reilly, S.S. [B& W Nuclear Technologies, Lynchburg, VA (United States)

    1995-09-01

    Droplet breakup at spacer grids and a cladding swelled and ruptured locations plays an important role in the cooling of nuclear fuel rods during the reflooding period of a loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR). During the reflood phase, a spacer grid affects the thermal-hydraulic system behavior through increased turbulence, droplet breakup due to impact on grid straps, grid rewetting, and liquid holdup due to grid form losses. Recently, models to simulate spacer grid effects and blockage and rupture effects on system thermal hydraulics were added to the B&W Nuclear Technologies (BWNT) version of the RELAP5/MOD2 computer code. Several FLECHT-SEASET forced reflood tests, CCTF Tests C1-19 and C2-6, SCTF Test S3-15, and G2 Test 561 were simulated using RELAP5/MOD2-B&W to verify the applicability of the model at the cladding swelled and rupture locations. The results demonstrate the importance of modeling the thermal-hydraulic effects due to grids, and clad swelling and rupture to correctly predict the clad temperature response during the reflood phase of large break LOCA. The RELAP5 models and the test results are described in this paper.

  3. Small break LOCA RELAP5/MOD3 uncertainty quantification: Bias and uncertainty evaluation for important phenomena

    International Nuclear Information System (INIS)

    Ortiz, M.G.; Ghan, L.S.; Vogl, J.

    1991-01-01

    The Nuclear Regulatory Commission (NRC) revised the Emergency Core Cooling System (ECCS) licensing rule to allow the use of Best Estimate (BE) computer codes, provided the uncertainty of the calculations are quantified and used in the licensing and regulation process. The NRC developed a generic methodology called Code Scaling, Applicability and Uncertainty (CSAU) to evaluate BE code uncertainties. The CSAU methodology was demonstrated with a specific application to a pressurized water reactor (PWR), experiencing a postulated large break loss-of-coolant accident (LBLOCA). The current work is part of an effort to adapt and demonstrate the CSAU methodology to a small break (SB) LOCA in a PWR of B and W design using RELAP5/MOD3 as the simulation tool. The subject of this paper is the Assessment and Ranging of Parameters (Element 2 of the CSAU methodology), which determines the contribution to uncertainty of specific models in the code

  4. A review of analyses of LOFT and semiscale tests made at IDAHO National Engineering Laboratory using RELAP5/MOD1

    International Nuclear Information System (INIS)

    Hall, P.C.

    1984-03-01

    Within the LOFT and Semiscale programs at INEL, many post-test analysis calculations have been performed using RELAP5/MOD1. In this report, these calculations are reviewed from the standpoint of assessing the performance of the code. Because the calculations were spread over a number of years, different cycles of RELAP5/MOD1 have been employed. Rather than explicitly assessing several cycles of the code, a more general view has been adopted and an attempt has been made to identify those areas in which the code is systematically successful or alternatively, frequently experiences difficulties. (author)

  5. Assessment of RELAP/MOD2 using large break loss-of-coolant experimental data

    International Nuclear Information System (INIS)

    Kao, L.; Liao, L.Y.; Liang, K.S.; Wang, S.F.; Chen, Y.B.

    1989-01-01

    In this paper assessment of RELAP5/MOD2 using LOFT L2-5 and Semiscale S-06-3 tests are performed to provide information of the code capability and its limitation in analyzing large break LOCA of a nuclear power plant. Experiments L2-5 and S-06-3 are conducted to simulate a hypothetical LOCA which results from a 200% double-ended offset shear break in the cold-leg of a typical pressurized water reactor by utilizing scaling facilities of the LOFT and Semiscale Mod-1 systems, respectively. The RELAP5/MOD2 calculations for both tests begin with break initiation and subsequent blowdown, continue through lower plenum refill, core reflood, and terminate with corewide quench. Major phenomena of both large break loss-of-coolant tests are well predicted by RELAP5/MOD2. The results indicate that the break flow and system pressure are reasonably calculated. The cladding temperature response during blowdown period, which is the major importance to a large break LOCA, calculated by RELAP5/MOD2 shows good agreement with the test data

  6. Improvements to the RELAP5/MOD3 reflood model and uncertainty quantification of reflood peak clad temperature

    International Nuclear Information System (INIS)

    Lee, Sang Yong; Chung, Bob Dong; Lee, Young Jin; Park, Chan Eok; Lee, Guy Hyung; Choi, Chul Jin

    1994-06-01

    This research aims to develop reliable, advanced system thermal-hydraulic computer code and to quantify the uncertainties of code to introduce the best estimate methodology of ECCS for LBLOCA. Although the one of best estimate code, RELAP5/MOD3.1 was introduced from USNRC, several deficiencies in its reflood model and some improvements have been made. The improvements consist of modification of reflood wall heat transfer package and adjusting the drop size in dispersed flow regime. The tome smoothing of wall vaporization and level tracking model are also added to eliminate the pressure spike and level oscillation. For the verification of improved model and quantification of associated uncertainty, the FLECHT-SEASET data were used and upper limit of uncertainty at 95% confidence level is evaluated. (Author) 30 refs., 49 figs., 2 tabs

  7. Improvements to the RELAP5/MOD3 reflood model and uncertainty quantification of reflood peak clad temperature

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Yong; Chung, Bob Dong; Lee, Young Jin; Park, Chan Eok; Lee, Guy Hyung; Choi, Chul Jin [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    This research aims to develop reliable, advanced system thermal-hydraulic computer code and to quantify the uncertainties of code to introduce the best estimate methodology of ECCS for LBLOCA. Although the one of best estimate code, RELAP5/MOD3.1 was introduced from USNRC, several deficiencies in its reflood model and some improvements have been made. The improvements consist of modification of reflood wall heat transfer package and adjusting the drop size in dispersed flow regime. The tome smoothing of wall vaporization and level tracking model are also added to eliminate the pressure spike and level oscillation. For the verification of improved model and quantification of associated uncertainty, the FLECHT-SEASET data were used and upper limit of uncertainty at 95% confidence level is evaluated. (Author) 30 refs., 49 figs., 2 tabs.

  8. Simulation of channel blockage for the IEA-R1 research reactor using RELAP/MOD 3

    International Nuclear Information System (INIS)

    Oliveira, Eduardo C.F. de; Castrillo, Lazara Silveira

    2015-01-01

    Research reactors have great importance in the area of nuclear technology, such as radioisotope production, research in nuclear physics, development of new technologies and staff training for reactor operation. The IEA-R1 is a Brazilian research reactor type pool, located at the IPEN (Instituto de Pesquisas Energeticas e Nucleares). In this work is simulated with computer code RELAP5 / MOD 3.3.2 gamma, the effect caused by partial and complete blockage of a channel in MTR fuel element of the IEA-R1 core, in order to analyzed the thermal hydraulic parameters on adjacent channels. (author)

  9. Simulation of channel blockage for the IEA-R1 research reactor using RELAP/MOD 3

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Eduardo C.F. de; Castrillo, Lazara Silveira, E-mail: ecfoliveira@hotmail.com, E-mail: lazara.castrillo@upe.br [Universidade de Pernambuco (UPE), Recife, PE (Brazil). Escola Politecnica de Pernambuco

    2015-07-01

    Research reactors have great importance in the area of nuclear technology, such as radioisotope production, research in nuclear physics, development of new technologies and staff training for reactor operation. The IEA-R1 is a Brazilian research reactor type pool, located at the IPEN (Instituto de Pesquisas Energeticas e Nucleares). In this work is simulated with computer code RELAP5 / MOD 3.3.2 gamma, the effect caused by partial and complete blockage of a channel in MTR fuel element of the IEA-R1 core, in order to analyzed the thermal hydraulic parameters on adjacent channels. (author)

  10. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru; Kawasaki, Nobuo; Kume, Etsuo; Adachi, Masaaki; Ogasawara, Shinobu

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the porting. In this porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. In the vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics Ntv Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model/multi-group model) MVP/GMVP on the Paragon are described. (author)

  11. Double blind post-test prediction for LOBI-MOD2 small break experiment A2-81 using RELAP5/MOD1/19 computer code as contribution to international CSNI-standardproblem no. 18

    International Nuclear Information System (INIS)

    Jacobs, G.; Mansoor, S.H.

    1986-06-01

    The first small break experiment A2-81 performed in the LOBI-MOD2 test facility was the base of the 18th international CSNI standard problem (ISP 18). Taking part in this exercise, a blind post-test prediction was performed using the light water reactor transient analysis code RELAP5/MOD1. This paper describes the input model preparation and summarizes the findings of the pre-calculation comparing the calculational results with the experimental data. The results show that there was a good agreement between prediction and experiment in the initial stage (up to 250 sec) of the transient and an adequate prediction of the global behaviour (thermal response of the core), which is important for safety related considerations. However, the prediction confirmed some deficiencies of the models in the code concerning vertical and horizontal stratification resulting in a high break mass flow and an erroneous distribution of mass over the primary loops. (orig.) [de

  12. Simulation of overpressure events with a Laguna Verde model for the RELAP code to conditions of extended power up rate

    International Nuclear Information System (INIS)

    Rodriguez H, A.; Araiza M, E.; Fuentes M, L.; Ortiz V, J.

    2012-10-01

    In this work the main results of the simulation of overpressure events are presented using a model of the nuclear power plant of Laguna Verde developed for the RELAP/SCDAPSIM code. As starting point we have the conformation of a Laguna Verde model that represents a stationary state to similar conditions to the operation of the power station with Extended Power Up rate (EPU). The transitory of simulated pressure are compared with those documented in the Final Safety Analysis Report of Laguna Verde (FSAR). The results of the turbine shot transitory with and without by-pass of the main turbine are showed, and the event of closes of all the valves of main vapor isolation. A preliminary simulation was made and with base in the results some adjustments were made for the operation with EPU, taking into account the Operation Technical Specifications of the power station. The results of the final simulations were compared and analyzed with the content in the FSAR. The response of the power station to the transitory, reflected in the model for RELAP, was satisfactory. Finally, comments about the improvement of the model are included, for example, the response time of the protection and mitigation systems of the power station. (Author)

  13. Involvement of Union Fenosa skills in the thermohydraulic area of the Jose Cabrera NPP PSA. Applications of the RELAPS5/MOD2 Code

    International Nuclear Information System (INIS)

    Martin, L.; Saenz Tejada, P.

    1993-01-01

    When performing a level 1 Probabilistic Safety Analysis (PSA) on a standard power plant, in order to model plant response to the potential occurrence of the various initiating events postulated in a PSA, reference documentation applicable to the type of plant in question is frequently consulted. Because of the specific design characteristics of the Jose Cabrera NPP, most of the reference documentation for the W-PWR-type power plants is not applicable to this plant. To fill in these gaps in the documentation and to construct the most realistic model of plant behaviour possible, assistance was sought from Union Fenosa by way of infrastructure, capabilities and thermohydraulic experience of the Nuclear Engineering and Fuel Group, and especially the use of calculations performed with the RELAP5/ MOD2 code. This paper will provide an overview of the general assistance rendered to the PSA by the technical experts in thermohydraulics, the calculations performed with RELAP5/MOD2 and the influence all of this has had on the development, quality and results of the Jose Cabrera NPP level 1 PSA Project. (author)

  14. Development and Assessment of the Appendix K Version of RELAP5-3D for LOCA Licensing Analysis

    International Nuclear Information System (INIS)

    Liang, Thomas K.S.; Chang, C.-J.; Hung, H.-J.

    2002-01-01

    In light water reactors, particularly the pressurized water reactor (PWR), the severity of a loss-of-coolant accident (LOCA) would limit how high the reactor power can operate. Although the best-estimate LOCA licensing methodology can provide the greatest margin on the peak cladding temperature (PCT) evaluation during a LOCA, it generally takes much more resources to develop. Instead, implementation of evaluation models required by Appendix K of 10CFR50 on an advanced thermal-hydraulic platform such as RELAP5, TRAC, etc., also can gain significant margin for the PCT calculation. Through compliance evaluation against Appendix K of 10CFR50, all of the required evaluation models have been implemented in RELAP5-3D. To verify and assess the development of the Appendix K version of RELAP5-3D, nine kinds of separate-effects experiments and eight sets of LOCA integral experiments were adopted. Through the assessments against separate-effects experiments, the success of the code modification in accordance with Appendix K of 10CFR50 was demonstrated. Besides, one set of a typical integral large-break LOCA from Loss-of-Fluid Test Facility experiments (L2-5) has also been applied to preliminarily evaluate the integral performance of the Appendix K version of RELAP5-3D. The PCT predicted by the evaluation models is greater than the one from best-estimate calculation in the whole LOCA history with the conservatism of 150 K, and the measured PCTs of L2-5 are also well bounded by the evaluation model calculation. Another seven sets of integral-effect experiments will be further applied in the next step to ensure the reasonable integral conservatism of the newly developed LOCA licensing analysis code (RELAP5-3DK/INER), which can cover all the phases of both large- and small LOCA in one code

  15. Thermal-hydraulic analysis under partial loss of flow accident hypothesis of a plate-type fuel surrounded by two water channels using RELAP5 code

    Directory of Open Access Journals (Sweden)

    Itamar Iliuk

    2016-01-01

    Full Text Available Thermal-hydraulic analysis of plate-type fuel has great importance to the establishment of safety criteria, also to the licensing of the future nuclear reactor with the objective of propelling the Brazilian nuclear submarine. In this work, an analysis of a single plate-type fuel surrounding by two water channels was performed using the RELAP5 thermal-hydraulic code. To realize the simulations, a plate-type fuel with the meat of uranium dioxide sandwiched between two Zircaloy-4 plates was proposed. A partial loss of flow accident was simulated to show the behavior of the model under this type of accident. The results show that the critical heat flux was detected in the central region along the axial direction of the plate when the right water channel was blocked.

  16. Computer codes used during upgrading activities at MINT TRIGA reactor

    International Nuclear Information System (INIS)

    Mohammad Suhaimi Kassim; Adnan Bokhari; Mohd Idris Taib

    1999-01-01

    MINT TRIGA Reactor is a 1-MW swimming pool nuclear research reactor commissioned in 1982. In 1993, a project was initiated to upgrade the thermal power to 2 MW. The IAEA assistance was sought to assist the various activities relevant to an upgrading exercise. For neutronics calculations, the IAEA has provided expert assistance to introduce the WIMS code, TRIGAP, and EXTERMINATOR2. For thermal-hydraulics calculations, PARET and RELAP5 were introduced. Shielding codes include ANISN and MERCURE. However, in the middle of 1997, MINT has decided to change the scope of the project to safety upgrading of the MINT Reactor. This paper describes some of the activities carried out during the upgrading process. (author)

  17. Analysis of Seven NEPTUN-III (Tight-Lattice) Bottom-Flooding Experiments with RELAP5/MOD3.3/BETA

    International Nuclear Information System (INIS)

    Analytis, G.Th.

    2004-01-01

    Seven tight-lattice NEPTUN-III bottom-flooding experiments are analyzed by using the frozen version of RELAP5, RELAP5/MOD3.3/BETA. This work is part of the Paul Scherrer Institute (PSI) contribution to the High Performance Light Water Reactor (HPLWR) European Union project and aims at assessing the capabilities of the code to model the reflooding phenomena in a tight hexagonal lattice (which was one of the core geometries considered at the time for an HPLWR) following a hypothetical loss-of-coolant accident scenario. Even though the latest version of the code has as a default the new PSI reflood model developed by the author, which was tested and assessed against reflooding data obtained at standard light water reactor lattices, this work shows that for tight lattices, the code underpredicts the peak clad temperatures measured during a series of reflooding experiments performed at the NEPTUN-III tight-lattice heater rod bundle facility. The reasons for these differences are discussed, and the (possible) changes needed in the framework of RELAP5/MOD3.3 for improving the modeling of reflooding in tight lattices are investigated

  18. Assessment of RELAP5/MOD3.1 with the LSTF SB-SG-06 experiment simulating a steam generator tube rupture transient

    International Nuclear Information System (INIS)

    Seul, K.W.; Bang, Y.S.; Lee, S.; Kim, H.J.

    1996-09-01

    The objective of the present work is to identify the predictability of RELAP5/MOD3.1 regarding thermal-hydraulic behavior during a steam generator tube rupture (SGTR). To evaluate the computed results, LSTF SB-SG-06 test data simulating the SGTR that occurred at the Mihama Unit 2 in 1991 are used. Also, some sensitivity studies of the code change in RELAP5, the break simulation model, and the break valve discharge coefficient are performed. The calculation results indicate that the RELAP5/MOD3.1 code predicted well the sequence of events and the major phenomena during the transient, such as the asymmetric loop behavior, reactor coolant system (RCS) cooldown and heat transfer by natural circulation, the primary and secondary system depressurization by the pressurizer auxiliary spray and the steam dump using the intact loop steam generator (SG) relief valve, and so on. However, there are some differences from the experimental data in the number of the relief valve cycling in the affected SG, and the flow regime of the hot leg with the pressurizer, and the break flow rates. Finally, the calculation also indicates that the coolant in the core could remain in a subcooled state as a result of the heat transfer caused by the natural circulation flow even if the reactor coolant pumps (RCPs) turned off and that the affected SG could be properly isolated to minimize the radiological release after the SGTR

  19. Assessment of RELAP5/MOD3.1 with the LSTF SB-SG-06 experiment simulating a steam generator tube rupture transient

    Energy Technology Data Exchange (ETDEWEB)

    Seul, K.W.; Bang, Y.S.; Lee, S.; Kim, H.J. [Korea Inst. of Nuclear Safety, Taejon (Korea, Republic of)

    1996-09-01

    The objective of the present work is to identify the predictability of RELAP5/MOD3.1 regarding thermal-hydraulic behavior during a steam generator tube rupture (SGTR). To evaluate the computed results, LSTF SB-SG-06 test data simulating the SGTR that occurred at the Mihama Unit 2 in 1991 are used. Also, some sensitivity studies of the code change in RELAP5, the break simulation model, and the break valve discharge coefficient are performed. The calculation results indicate that the RELAP5/MOD3.1 code predicted well the sequence of events and the major phenomena during the transient, such as the asymmetric loop behavior, reactor coolant system (RCS) cooldown and heat transfer by natural circulation, the primary and secondary system depressurization by the pressurizer auxiliary spray and the steam dump using the intact loop steam generator (SG) relief valve, and so on. However, there are some differences from the experimental data in the number of the relief valve cycling in the affected SG, and the flow regime of the hot leg with the pressurizer, and the break flow rates. Finally, the calculation also indicates that the coolant in the core could remain in a subcooled state as a result of the heat transfer caused by the natural circulation flow even if the reactor coolant pumps (RCPs) turned off and that the affected SG could be properly isolated to minimize the radiological release after the SGTR.

  20. Prediction of LOFT L1-4 experiment

    International Nuclear Information System (INIS)

    Soda, Kunihisa; Sasaki, Shinobu; Akimoto, Masayuki; Koizumi, Yasuo; Araya, Fumimasa

    1977-10-01

    LOFT L1-4 experimental results were predicted by LOFT Analysis Group and Code Development Group using RELAP-4J and ALARM-P1 respectively. The input data prepared by the former group were used in both the analyses. Thus any differences in the results should stem from the differences in code performance characteristics of the two codes. (1) The coolant behaviors predicted by RELAP-4J and ALARM-P1 are in good agreement although some differences do exist between these two calculation models. (2) Large difference is seen in coolant flow rate across the pump. The coast down and the flow rate by ALARM-P1 are larger and smaller respectively than by RELAP-4J. (3) An explicit method of the ALARM-P1 leads to unstable calculation at a T shaped junction when one of the two volumes connected by the junction is filled with subcooled water. (4) Coolant flow in the downcomer, heat transfer to and from the steam generator secondary and suppression tank behavior must be modified to better predict the experimental results. (5) Additional instrumentation in reflood assist and ECC injection lines are necessary to better nderstand the coolant behavior. (auth.)

  1. Plant balance model for RELAP/SCDAPSIM

    International Nuclear Information System (INIS)

    Mendoza M, R.; Filio L, C.; Araiza M, E.; Ortiz V, J.

    2017-09-01

    In this work we developed an integral model for a nuclear power plant and have a more general picture of what happens in both the Nuclear Steam Supply System (NSSS) and the Balance of Plant (Bop) system during abnormal events that are presented in operation. RELAP/SCDAPSIM (RSS) is a computation code of the type of best estimate that can simulate the transient and accident behavior of a nuclear installation. The development of a Bop model for RSS can result in the simulation of transients such as turbine trip due to loss of vacuum in the main steam condenser. This work shows the development of models of the Bop main components for the RSS code, such as the set of high and low pressure turbines, as well as their steam extractions to the feed water heaters, the main steam condenser, a feed water heater and the condensate and water feed pumps. This new model of the Plant Balance system was then coupled to the NSSS model that is already in RSS. First, results of the steady state with this new integral model are show, to later show results of the transients simulation: 1) turbine trip due to loss of vacuum in the main steam condenser; 2) loss of condensate pumps; and 3) failure of the feed water heater. (Author)

  2. Solving implicit multi-mesh flow and conjugate heat transfer problems with RELAP-7

    International Nuclear Information System (INIS)

    Zou, L.; Peterson, J.; Zhao, H.; Zhang, H.; Andrs, D.; Martineau, R.

    2013-01-01

    The fully implicit simulation capability of RELAP-7 to solve multi-mesh flow and conjugate heat transfer problems for reactor system safety analysis is presented. Compared to general single-mesh simulations, the reactor system safety analysis-type of code has unique challenges due to its highly simplified, interconnected, one-dimensional, and zero-dimensional flow network describing multiple physics with significantly different time and length scales. To use the Jacobian-free Newton Krylov-type of solver, preconditioning is generally required for the Krylov method. The uniqueness of the reactor safety analysis-type of code in treating the interconnected flow network and conjugate heat transfer also introduces challenges in providing preconditioning matrix. Typical flow and conjugate heat transfer problems involved in reactor safety analysis using RELAP-7, as well as the special treatment on the preconditioning matrix are presented in detail. (authors)

  3. RELAP/SCDAPSIM Reactor System Simulator Development and Training for University and Reactor Applications

    International Nuclear Information System (INIS)

    Hohorst, J.K.; Allison, C.M.

    2010-01-01

    The RELAP/SCDAPSIM code, designed to predict the behaviour of reactor systems during normal and accident conditions, is being developed as part of an international nuclear technology development program called SDTP (SCDAP Development and Training Program). SDTP involves more than 60 organizations in 28 countries. One of the important applications of the code is for simulator training of university faculty and students, reactor analysts, and reactor operations and technical support staff. Examples of RELAP/SCDAPSIM-based system thermal hydraulic and severe accident simulator packages include the SAFSIM simulator developed by NECSA for the SAFARI research reactor in South Africa, university-developed simulators at the University of Mexico and Shanghai Jiao Tong University in China, and commercial VISA and RELSIM packages used for analyst and reactor operations staff training. This paper will briefly describe the different packages/facilities. (authors)

  4. RELAP/SCDAPSIM Reactor System Simulator Development and Training for University and Reactor Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hohorst, J.K.; Allison, C.M. [Innovative Systems Software, 1242 South Woodruff Avenue, Idaho Falls, Idaho 83404 (United States)

    2010-07-01

    The RELAP/SCDAPSIM code, designed to predict the behaviour of reactor systems during normal and accident conditions, is being developed as part of an international nuclear technology development program called SDTP (SCDAP Development and Training Program). SDTP involves more than 60 organizations in 28 countries. One of the important applications of the code is for simulator training of university faculty and students, reactor analysts, and reactor operations and technical support staff. Examples of RELAP/SCDAPSIM-based system thermal hydraulic and severe accident simulator packages include the SAFSIM simulator developed by NECSA for the SAFARI research reactor in South Africa, university-developed simulators at the University of Mexico and Shanghai Jiao Tong University in China, and commercial VISA and RELSIM packages used for analyst and reactor operations staff training. This paper will briefly describe the different packages/facilities. (authors)

  5. Assessment of Flow Instability in Passive Auxiliary Feedwater System (PAFS) Using RELAP5

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Seong-Su; Hong, Soon-Joon [FNC Tech., Yongin (Korea, Republic of); Cheon, Jong; Kim, Han-Gon [KHNP, Daejeon (Korea, Republic of)

    2015-10-15

    In this study, the occurrence possibility of both instabilities in PAFS is assessed with the best-estimate thermal hydraulic code, RELAP5. From the RELAP5 code analysis, the Ledinegg instability might not occur in PAFS. The DWO might occur in PAFS but the effect of the oscillation on the heat removal capacity of PAFS was not large. Therefore, it is concluded that PAFS is safe in terms of flow instabilities. Since PAFS is two-phase flow system, flow instabilities may occur. Flow instabilities may cause the severe deterioration of heat removal capability of PAFS due to the reduction of the condensate flow. For the reliable operation of PAFS, it is required to assess the flow instabilities in PAFS. The Ledinegg-type instability and the Density Wave Oscillation (DWO) are the representative static flow instability and the dynamic flow instability, respectively.

  6. A parallelization study of the general purpose Monte Carlo code MCNP4 on a distributed memory highly parallel computer

    International Nuclear Information System (INIS)

    Yamazaki, Takao; Fujisaki, Masahide; Okuda, Motoi; Takano, Makoto; Masukawa, Fumihiro; Naito, Yoshitaka

    1993-01-01

    The general purpose Monte Carlo code MCNP4 has been implemented on the Fujitsu AP1000 distributed memory highly parallel computer. Parallelization techniques developed and studied are reported. A shielding analysis function of the MCNP4 code is parallelized in this study. A technique to map a history to each processor dynamically and to map control process to a certain processor was applied. The efficiency of parallelized code is up to 80% for a typical practical problem with 512 processors. These results demonstrate the advantages of a highly parallel computer to the conventional computers in the field of shielding analysis by Monte Carlo method. (orig.)

  7. Blind-blind prediction by RELAP5/MOD1 for a 0.1% very small cold-leg break experiment at ROSA-IV large-scale test facility

    International Nuclear Information System (INIS)

    Koizumi, Y.; Kumamaru, H.; Kukita, Y.; Kawaji, M.; Osakabe, M.; Schultz, R.R.; Tanaka, M.; Tasaka, K.

    1986-01-01

    The large-scale test facility (LSTF) of the Rig of Safety Assessment No. 4 (ROSA-IV) program is a volumetrically scaled (1/48) pressurized water reactor (PWR) system with an electrically heated core used for integral simulation of small break loss-of-coolant accidents (LOCAs) and operational transients. The 0.1% very small cold-leg break experiment was conducted as the first integral experiment at the LSTF. The test provided a good opportunity to truly assess the state-of-the-art predictability of the safety analysis code RELAP5/MODI CY18 through a blind-blind prediction of the experiment since there was no prior experience in analyzing the experimental data with the code; furthermore, detailed operational characteristics of LSTF were not yet known. The LOCA transient was mitigated by high-pressure charging pump injection to the primary system and bleed and feed operation of the secondary system. The simulated reactor system was safely placed in hot standby condition by engineered safety features similar to those on a PWR. Natural circulation flow was established to effectively remove the decay heat generated in the core. No cladding surface temperature excursion was observed. The RELAP5 code showed good capability to predict thermal-hydraulic phenomena during the very small break LOCA transient. Although all the information needed for the analysis by the RELAP5 code was obtained solely from the engineering drawings for fabrication and the operational specifications, the code predicted key phenomena satisfactorily

  8. Prediction of thermal-Hydraulic phenomena in the LBLOCA experiment L2-3 using RELAP5/MOD2

    International Nuclear Information System (INIS)

    Bang, Young Seok; Chung, Bub Dong; Kim, Hho Jung

    1991-01-01

    The LOFT LOCE L2-3 was simulated using the RELAP5/MOD2 Cycle 36.04 code to assess its capability in predicting the thermal-hydraulic phenomena in LBLOCA of a PWR. The reactor vessel was simulated with two core channels and split downcomer modeling for a base case calculation using the frozen code. The result of the base calculation showed that the code predicted the hydraulic behavior, and the blowdown thermal response at high power region of the core reasonably and that the code had deficiencies in the critical flow model during subcooled-two-phase transition period, in the CHF correlation at high mass flux and in the blowdown rewet criteria. An overprediction of coolant inventory due to the deficiencies yielded the poor prediction of reflood thermal response. Improvement of the code, RELAP5/MOD2 Cycle 36.04, based on the sensitivity study increased the accuracy of the prediction of the rewet phenomena. (Author)

  9. A generic semi-implicit coupling methodology for use in RELAP5-3D(c)

    International Nuclear Information System (INIS)

    Weaver, W.L.; Tomlinson, E.T.; Aumiller, D.L.

    2002-01-01

    A generic semi-implicit coupling methodology has been developed and implemented in the RELAP5-3D (c) computer program. This methodology allows RELAP5-3D (c) to be used with other computer programs to perform integrated analyses of nuclear power reactor systems and related experimental facilities. The coupling methodology potentially allows different programs to be used to model different portions of the system. The programs are chosen based on their capability to model the phenomena that are important in the simulation in the various portions of the system being considered and may use different numbers of conservation equations to model fluid flow in their respective solution domains. The methodology was demonstrated using a test case in which the test geometry was divided into two parts, each of which was solved as a RELAP5-3D (c) simulation. This test problem exercised all of the semi-implicit coupling features that were implemented in RELAP5-3D (c) The results of this verification test case show that the semi-implicit coupling methodology produces the same answer as the simulation of the test system as a single process

  10. Comparative study of Thermal Hydraulic Analysis Codes for Pressurized Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yang Hoon; Jang, Mi Suk; Han, Kee Soo [Nuclear Engineering Service and Solution Co. Ltd., Daejeon (Korea, Republic of)

    2015-05-15

    Various codes are used for the thermal hydraulic analysis of nuclear reactors. The use of some codes among these is limited by user and some codes are not even open to general person. Thus, the use of alternative code is considered for some analysis. In this study, simple thermal hydraulic behaviors are analyzed using three codes to show that alternative codes are possible for the analysis of nuclear reactors. We established three models of the simple u-tube manometer using three different codes. RELAP5 (Reactor Excursion and Leak Analysis Program), SPACE (Safety and Performance Analysis CodE for nuclear power Plants), GOTHIC (Generation of Thermal Hydraulic Information for Containments) are selected for this analysis. RELAP5 is widely used codes for the analysis of system behavior of PWRs. SPACE has been developed based on RELAP5 for the analysis of system behavior of PWRs and licensing of the code is in progress. And GOTHIC code also has been widely used for the analysis of thermal hydraulic behavior in the containment system. The internal behavior of u-tube manometer was analyzed by RELAP5, SPACE and GOTHIC codes. The general transient behavior was similar among 3 codes. However, the stabilized status of the transient period analyzed by REPAP5 was different from the other codes. It would be resulted from the different physical models used in the other codes, which is specialized for the multi-phase thermal hydraulic behavior analysis.

  11. Simulation of Targets Feeding Pipe Rupture in Wendelstein 7-X Facility Using RELAP5 and COCOSYS Codes

    Science.gov (United States)

    Kaliatka, T.; Povilaitis, M.; Kaliatka, A.; Urbonavicius, E.

    2012-10-01

    Wendelstein nuclear fusion device W7-X is a stellarator type experimental device, developed by Max Planck Institute of plasma physics. Rupture of one of the 40 mm inner diameter coolant pipes providing water for the divertor targets during the "baking" regime of the facility operation is considered to be the most severe accident in terms of the plasma vessel pressurization. "Baking" regime is the regime of the facility operation during which plasma vessel structures are heated to the temperature acceptable for the plasma ignition in the vessel. This paper presents the model of W7-X cooling system (pumps, valves, pipes, hydro-accumulators, and heat exchangers), developed using thermal-hydraulic state-of-the-art RELAP5 Mod3.3 code, and model of plasma vessel, developed by employing the lumped-parameter code COCOSYS. Using both models the numerical simulation of processes in W7-X cooling system and plasma vessel has been performed. The results of simulation showed, that the automatic valve closure time 1 s is the most acceptable (no water hammer effect occurs) and selected area of the burst disk is sufficient to prevent pressure in the plasma vessel.

  12. Safety analysis code SCTRAN development for SCWR and its application to CGNPC SCWR

    International Nuclear Information System (INIS)

    Wu, Pan; Gou, Junli; Shan, Jianqiang; Jiang, Yang; Yang, Jue; Zhang, Bo

    2013-01-01

    Highlights: ► A new safety analysis code named SCTRAN is developed for SCWRs. ► Capability of SCTRAN is verified by comparing with code APROS and RELAP5-3D. ► A new passive safety system is proposed for CGNPC SCWR and analyzed with SCTRAN. ► CGNPC SCWR is able to cope with two critical accidents for SCWRs, LOFA and LOCA. - Abstract: Design analysis is one of the main difficulties during the research and design of SCWRs. Currently, the development of safety analysis code for SCWR is still in its infancy all around the world, and very few computer codes could carry out the trans-critical calculations where significant changes in water properties would take place. In this paper, a safety analysis code SCTRAN for SCWRs has been developed based on code RETRAN-02, the best estimate code used for safety analysis of light water reactors. The ability of SCTRAN code to simulate transients where both supercritical and subcritical regimes are encountered has been verified by comparing with APROS and RELAP5-3D codes. Furthermore, the LOFA and LOCA transients for the CGNPC SCWR design were analyzed with SCTRAN code. The characteristics and performance of the passive safety systems applied to CGNPC SCWR were evaluated. The results show that: (1) The SCTRAN computer code developed in this study is capable to perform design analysis for SCWRs; (2) During LOFA and LOCA accidents in a CGNPC SCWR, the passive safety systems would significantly mitigate the consequences of these transients and enhance the inherent safety

  13. Development of the Computer Code to Determine an Individual Radionuclides in the Rad-wastes Container for Ulchin Units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D.W.; Chi, J.H.; Goh, E.O. [Korea Electric Power Research Institute, Taejon (Korea)

    2001-07-01

    A computer program, RASSAY was developed to evaluate accurately the activities of various nuclides in the rad-waste container for Ulchin units 3 and 4. This is the final report of the project, {sup D}evelopment of the Computer Code to Determine an Individual Radionuclides in the Rad-wastes Container for Ulchin Units 3 and 4 and includes the followings; 1) Structure of the computer code, RASSAY 2) An example of surface dose calculation by computer simulation using MCNP code 3) Methods of sampling and activity measurement of various Rad-wastes. (author). 21 refs., 35 figs., 6 tabs.

  14. Modelling of Cold Water Hammer with WAHA code

    International Nuclear Information System (INIS)

    Gale, J.; Tiselj, I.

    2003-01-01

    The Cold Water Hammer experiment described in the present paper is a simple facility where overpressure accelerates a column of liquid water into the steam bubble at the closed vertical end of the pipe. Severe water hammer with high pressure peak occurs when the vapor bubble condenses and the liquid column hits the closed end of the pipe. Experimental data of Forschungszentrum Rossendorf are being used to test the newly developed computer code WAHA and the computer code RELAP5. Results show that a small amount of noncondensable air in the steam bubble significantly affects the magnitude of the calculated pressure peak, while the wall friction and condensation rate only slightly affect the simulated phenomena. (author)

  15. Numerical and computational aspects of the coupled three-dimensional core/ plant simulations: organization for economic cooperation and development/ U.S. nuclear regulatory commission pressurized water reactor main-steam-line-break benchmark-II. 3. Analysis of the OECD TMI-1 Main-Steam- Line-Break Benchmark Accident Using the Coupled RELAP5/PANTHER Codes

    International Nuclear Information System (INIS)

    Schneidesch, C.R.; Guisset, J.P.; Zhang, J.; Bryce, P.; Parkes, M.

    2001-01-01

    The RELAP5 best-estimate thermal-hydraulic system code has been coupled with the PANTHER three-dimensional (3-D) neutron kinetics code via the TALINK dynamic data exchange control and processing tool. The coupled RELAP5/PANTHER code package is being qualified and will be used at British Energy (BE) and Tractebel Energy Engineering (TEE), independently, to analyze pressurized water reactor (PWR) transients where strong core-system interactions occur. The Organization for Economic Cooperation and Development/Nuclear Energy Agency PWR Main-Steam-Line-Break (MSLB) Benchmark problem was performed to demonstrate the capability of the coupled code package to simulate such transients, and this paper reports the BE and TEE contributions. In the first exercise, a point-kinetics (PK) calculation is performed using the RELAP5 code. Two solutions have been derived for the PK case. The first corresponds to scenario, 1 where calculations are carried out using the original (BE) rod worth and where no significant return to power (RTP) occurs. The second corresponds to scenario 2 with arbitrarily reduced rod worth in order to obtain RTP (and was not part of the 'official' results). The results, as illustrated in Fig. 1, show that the thermalhydraulic system response and rod worth are essential in determining the core response. The second exercise consists of a 3-D neutron kinetics transient calculation driven by best-estimate time-dependent core inlet conditions on a 18 T and H zones basis derived from TRAC-PF1/MOD2 (PSU), again analyzing two scenarios of different rod worths. Two sets of PANTHER solutions were submitted for exercise 2. The first solution uses a spatial discretization of one node per assembly and 24 core axial layers for both flux and T and H mesh. The second is characterized by spatial refinement (2 x 2 nodes per assembly, 48 core layers for flux, and T and H calculation), time refinement (half-size time steps), and an increased radial discretization for solution

  16. Aztheca Code; Codigo Aztheca

    Energy Technology Data Exchange (ETDEWEB)

    Quezada G, S.; Espinosa P, G. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, San Rafael Atlixco No. 186, Col. Vicentina, 09340 Ciudad de Mexico (Mexico); Centeno P, J.; Sanchez M, H., E-mail: sequga@gmail.com [UNAM, Facultad de Ingenieria, Ciudad Universitaria, Circuito Exterior s/n, 04510 Ciudad de Mexico (Mexico)

    2017-09-15

    This paper presents the Aztheca code, which is formed by the mathematical models of neutron kinetics, power generation, heat transfer, core thermo-hydraulics, recirculation systems, dynamic pressure and level models and control system. The Aztheca code is validated with plant data, as well as with predictions from the manufacturer when the reactor operates in a stationary state. On the other hand, to demonstrate that the model is applicable during a transient, an event occurred in a nuclear power plant with a BWR reactor is selected. The plant data are compared with the results obtained with RELAP-5 and the Aztheca model. The results show that both RELAP-5 and the Aztheca code have the ability to adequately predict the behavior of the reactor. (Author)

  17. Investigation of the Phebus FPT0 bundle degradation with SCDAP/RELAP5

    International Nuclear Information System (INIS)

    Smit, S.O.; Sengpiel, W.; Hering, W.

    1998-04-01

    The in-pile experiment Phebus FPT0 provides an excellent data base reflecting the course and the consequences of a severe core melt accident starting from the core uncovery up to bundle degradation and molten pool formation. In the IRS post-test calculations of the Phebus FPT0 have been performed with SCDAP/RELAP5. A detailed parameter study has shown that some models used in the code still have to be improved and that some parametric models need to be substituted by more physical models. In the context of this parameter study, the heat transfer through the Phebus FPT0 shroud has been identified to be one of the most influential physical processes on the course of bundle degradation. Especially the gap behaviour and the heat transport through the gaps of the FPT0 shroud have shown to be insufficiently modeled by the original code version. Therefore, the shroud heat transfer model has been improved to consider dynamic gap closure by thermal expansion of the shroud materials and to take into account radiation heat transfer through open gaps. In this report, the results of the parameter study for FPT0 obtained with the original code are compared to the results of a reference calculation which includes the improved shroud model. It is shown that SCDAP/RELAP5 is now able to calculate the heat losses through a shroud containing gas-filled gaps like that of Phebus FPT0 quite accurately. Thus, SCDAP/RELAP5 now can also be used more successfully for test analyses of experiments like Phebus FPT1 and FPT2, and of the QUENCH test series. (orig./MM) [de

  18. Development of a Relap based Nuclear Plant Analyser with 3-D graphics using OpenGL and Object Relap

    International Nuclear Information System (INIS)

    Lee, Young Jin

    2010-01-01

    A 3-D Graphic Nuclear Plant Analyzer (NPA) program was developed using GLScene and the TRelap. GLScene is an OpenGL based 3D graphics library for the Delphi object-oriented program language, and it implements the OpenGL functions in forms suitable for programming with Delphi. TRelap is an object wrapper developed by the author to easily implement the Relap5 thermal hydraulic code under object oriented programming environment. The 3-D Graphic NPA was developed to demonstrate the superiority of the object oriented programming approach in developing complex programs

  19. Current and anticipated uses of thermal-hydraulic codes in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Teschendorff, V.; Sommer, F.; Depisch, F.

    1997-07-01

    In Germany, one third of the electrical power is generated by nuclear plants. ATHLET and S-RELAP5 are successfully applied for safety analyses of the existing PWR and BWR reactors and possible future reactors, e.g. EPR. Continuous development and assessment of thermal-hydraulic codes are necessary in order to meet present and future needs of licensing organizations, utilities, and vendors. Desired improvements include thermal-hydraulic models, multi-dimensional simulation, computational speed, interfaces to coupled codes, and code architecture. Real-time capability will be essential for application in full-scope simulators. Comprehensive code validation and quantification of uncertainties are prerequisites for future best-estimate analyses.

  20. Current and anticipated uses of thermal-hydraulic codes in Germany

    International Nuclear Information System (INIS)

    Teschendorff, V.; Sommer, F.; Depisch, F.

    1997-01-01

    In Germany, one third of the electrical power is generated by nuclear plants. ATHLET and S-RELAP5 are successfully applied for safety analyses of the existing PWR and BWR reactors and possible future reactors, e.g. EPR. Continuous development and assessment of thermal-hydraulic codes are necessary in order to meet present and future needs of licensing organizations, utilities, and vendors. Desired improvements include thermal-hydraulic models, multi-dimensional simulation, computational speed, interfaces to coupled codes, and code architecture. Real-time capability will be essential for application in full-scope simulators. Comprehensive code validation and quantification of uncertainties are prerequisites for future best-estimate analyses