WorldWideScience

Sample records for reinforced plastic knee-ankle-foot

  1. The effect of a knee ankle foot orthosis incorporating an active knee mechanism on gait of a person with poliomyelitis.

    Science.gov (United States)

    Arazpour, Mokhtar; Chitsazan, Ahmad; Bani, Monireh Ahmadi; Rouhi, Gholamreza; Ghomshe, Farhad Tabatabai; Hutchins, Stephen W

    2013-10-01

    The aim of this case study was to identify the effect of a powered stance control knee ankle foot orthosis on the kinematics and temporospatial parameters of walking by a person with poliomyelitis when compared to a knee ankle foot orthosis. A knee ankle foot orthosis was initially manufactured by incorporating drop lock knee joints and custom molded ankle foot orthoses and fitted to a person with poliomyelitis. The orthosis was then adapted by adding electrically activated powered knee joints to provide knee extension torque during stance and also flexion torque in swing phase. Lower limb kinematic and kinetic data plus data for temporospatial parameters were acquired from three test walks using each orthosis. Walking speed, step length, and vertical and horizontal displacement of the pelvis decreased when walking with the powered stance control knee ankle foot orthosis compared to the knee ankle foot orthosis. When using the powered stance control knee ankle foot orthosis, the knee flexion achieved during swing and also the overall pattern of walking more closely matched that of normal human walking. The reduced walking speed may have caused the smaller compensatory motions detected when the powered stance control knee ankle foot orthosis was used. The new powered SCKAFO facilitated controlled knee flexion and extension during ambulation for a volunteer poliomyelitis person.

  2. The influence of a powered knee-ankle-foot orthosis on walking in poliomyelitis subjects: A pilot study.

    Science.gov (United States)

    Arazpour, Mokhtar; Moradi, Alireza; Samadian, Mohammad; Bahramizadeh, Mahmood; Joghtaei, Mahmoud; Ahmadi Bani, Monireh; Hutchins, Stephen W; Mardani, Mohammad A

    2016-06-01

    Traditionally, the anatomical knee joint is locked in extension when walking with a conventional knee-ankle-foot orthosis. A powered knee-ankle-foot orthosis was developed to provide restriction of knee flexion during stance phase and active flexion and extension of the knee during swing phase of gait. The purpose of this study was to determine differences of the powered knee-ankle-foot orthosis compared to a locked knee-ankle-foot orthosis in kinematic data and temporospatial parameters during ambulation. Quasi-experimental design. Subjects with poliomyelitis (n = 7) volunteered for this study and undertook gait analysis with both the powered and the conventional knee-ankle-foot orthoses. Three trials per orthosis were collected while each subject walked along a 6-m walkway using a calibrated six-camera three-dimensional video-based motion analysis system. Walking with the powered knee-ankle-foot orthosis resulted in a significant reduction in both walking speed and step length (both 18%), but a significant increase in stance phase percentage compared to walking with the conventional knee-ankle-foot orthosis. Cadence was not significantly different between the two test conditions (p = 0.751). There was significantly higher knee flexion during swing phase and increased hip hiking when using the powered orthosis. The new powered orthosis permitted improved knee joint kinematic for knee-ankle-foot orthosis users while providing knee support in stance and active knee motion in swing in the gait cycle. Therefore, the new powered orthosis provided more natural knee flexion during swing for orthosis users compared to the locked knee-ankle-foot orthosis. This orthosis has the potential to improve knee joint kinematics and gait pattern in poliomyelitis subjects during walking activities. © The International Society for Prosthetics and Orthotics 2015.

  3. Effect of an ankle-foot orthosis on knee joint mechanics: a novel conservative treatment for knee osteoarthritis.

    Science.gov (United States)

    Fantini Pagani, Cynthia H; Willwacher, Steffen; Benker, Rita; Brüggemann, Gert-Peter

    2014-12-01

    Several conservative treatments for medial knee osteoarthritis such as knee orthosis and laterally wedged insoles have been shown to reduce the load in the medial knee compartment. However, those treatments also present limitations such as patient compliance and inconsistent results regarding the treatment success. To analyze the effect of an ankle-foot orthosis on the knee adduction moment and knee joint alignment in the frontal plane in subjects with knee varus alignment. Controlled laboratory study, repeated measurements. In total, 14 healthy subjects with knee varus alignment were analyzed in five different conditions: without orthotic, with laterally wedged insoles, and with an ankle-foot orthosis in three different adjustments. Three-dimensional kinetic and kinematic data were collected during gait analysis. Significant decreases in knee adduction moment, knee lever arm, and joint alignment in the frontal plane were observed with the ankle-foot orthosis in all three different adjustments. No significant differences could be found in any parameter while using the laterally wedged insoles. The ankle-foot orthosis was effective in reducing the knee adduction moment. The decreases in this parameter seem to be achieved by changing the knee joint alignment and thereby reducing the knee lever arm in the frontal plane. This study presents a novel approach for reducing the load in the medial knee compartment, which could be developed as a new treatment option for patients with medial knee osteoarthritis. © The International Society for Prosthetics and Orthotics 2013.

  4. Effect of carbon-composite knee-ankle-foot orthoses on walking efficiency and gait in former polio patients

    NARCIS (Netherlands)

    Brehm, Merel-Anne; Beelen, Anita; Doorenbosch, Caroline A. M.; Harlaar, Jaap; Nollet, Frans

    2007-01-01

    Objective: To investigate the effects of total-contact fitted carbon-composite knee-ankle-foot orthoses (KAFOs) on energy cost of walking in patients with former polio who normally wear a conventional leather/metal KAFO or plastic/metal KAFO. Design: A prospective uncontrolled study with a multiple

  5. The physiological cost index of walking with a powered knee-ankle-foot orthosis in subjects with poliomyelitis: A pilot study.

    Science.gov (United States)

    Arazpour, Mokhtar; Ahmadi Bani, Monireh; Samadian, Mohammad; Mousavi, Mohammad E; Hutchins, Stephen W; Bahramizadeh, Mahmood; Curran, Sarah; Mardani, Mohammad A

    2016-08-01

    A powered knee-ankle-foot orthosis was developed to provide restriction of knee flexion during stance phase and active flexion and extension of the knee during swing phase of gait. The purpose of this study was to determine its effect on the physiological cost index, walking speed and the distance walked in people with poliomyelitis compared to when walking with a knee-ankle-foot orthosis with drop lock knee joints. Quasi experimental study. Seven subjects with poliomyelitis volunteered for the study and undertook gait analysis with both types of knee-ankle-foot orthosis. Walking with the powered knee-ankle-foot orthosis significantly reduced walking speed (p = 0.015) and the distance walked (p = 0.004), and also, it did not improve physiological cost index values (p = 0.009) compared to walking with the locked knee-ankle-foot orthosis. Using a powered knee-ankle-foot orthosis did not significantly improve any of the primary outcome measures during walking for poliomyelitis subjects. This powered knee-ankle-foot orthosis design did not improve the physiological cost index of walking for people with poliomyelitis when compared to walking with a knee-ankle-foot orthosis with drop lock knee joints. This may have been due to the short training period used or the bulky design and additional weight of the powered orthosis. Further research is therefore warranted. © The International Society for Prosthetics and Orthotics 2015.

  6. Cross-Sectional Contrast Between Individuals With Foot/Ankle vs Knee Osteoarthritis for Obesity and Low Education on Health-Related Quality of Life.

    Science.gov (United States)

    Perruccio, Anthony V; Gandhi, Rajiv; Lau, Johnny T C; Syed, Khalid A; Mahomed, Nizar N; Rampersaud, Y Raja

    2016-01-01

    Improving health-related quality of life (HRQoL) necessitates an understanding of the influence of patient characteristics on, and interrelationship among, HRQoL domains. In osteoarthritis (OA), these associations have predominantly been examined in hip/knee populations. We investigated whether there were differences in these associations between foot/ankle and knee OA samples. Individuals seeking orthopedic care for foot/ankle or knee OA completed a questionnaire pre-consultation, including HRQoL domains (bodily pain [BP], physical [PF] and social functioning [SF], and mental [MH] and general health [GH]), obesity, comorbidity, and sociodemographic characteristics. Associations were examined via stratified path analysis (foot/ankle vs knee). Foot/ankle: n = 180, mean age = 55 (range: 25 to 82), 52% female. Knee: n = 253, mean age = 62 (range: 26 to 92), 51% female. The interrelationship among HRQoL domains was generally similar between groups. However, the influence of patient characteristics differed. Low educational status was associated with worse scores for GH, MH, and SF in the foot/ankle group, whereas no significant effects were found in the knee group. Obesity was associated with worse scores for SF, BP, and GH in the foot/ankle compared to the knee group. Patient characteristics explained considerably more of the variation in domain scores in the foot/ankle group. There are significant differences in the impact of patient characteristics on HRQoL domains in foot/ankle versus knee OA patients. Therefore, a universal approach to patient education/intervention to improve HRQoL in lower-extremity OA is not likely to achieve optimal results. Based on these findings, we recommend joint-specific patient education, with a particular emphasis on patient characteristics among the foot/ankle OA population. Level III, retrospective comparative study. © The Author(s) 2015.

  7. Effect of carbon-composite knee-ankle-foot orthoses on walking efficiency and gait in former polio patients.

    Science.gov (United States)

    Brehm, Merel-Anne; Beelen, Anita; Doorenbosch, Caroline A M; Harlaar, Jaap; Nollet, Frans

    2007-10-01

    To investigate the effects of total-contact fitted carbon-composite knee-ankle-foot orthoses (KAFOs) on energy cost of walking in patients with former polio who normally wear a conventional leather/metal KAFO or plastic/metal KAFO. A prospective uncontrolled study with a multiple baseline and follow-up design. Follow-up measurements continued until 26 weeks after intervention. Twenty adults with polio residuals (mean age 55 years). Each participant received a new carbon-composite KAFO, fitted according to a total-contact principle, which resulted in a rigid, lightweight and well-fitting KAFO. Energy cost of walking, walking speed, biomechanics of gait, physical functioning and patient satisfaction. The energy cost decreased significantly, by 8%, compared with the original KAFO. Furthermore, the incremention energy cost during walking with the carbon-composite KAFO was reduced by 18% towards normative values. An improvement in knee flexion, forward excursion of the centre of pressure, peak ankle moment, and timing of peak ankle power were significantly associated with the decrease in energy cost. Walking speed and physical functioning remained unchanged. In patients with former polio, carbon-composite KAFOs are superior to conventional leather/metal and plastic/metal KAFOs with respect to improving walking efficiency and gait, and are therefore important in reducing overuse and maintaining functional abilities in polio survivors.

  8. A pneumatically powered knee-ankle-foot orthosis (KAFO with myoelectric activation and inhibition

    Directory of Open Access Journals (Sweden)

    Ferris Daniel P

    2009-06-01

    Full Text Available Abstract Background The goal of this study was to test the mechanical performance of a prototype knee-ankle-foot orthosis (KAFO powered by artificial pneumatic muscles during human walking. We had previously built a powered ankle-foot orthosis (AFO and used it effectively in studies on human motor adaptation, locomotion energetics, and gait rehabilitation. Extending the previous AFO to a KAFO presented additional challenges related to the force-length properties of the artificial pneumatic muscles and the presence of multiple antagonistic artificial pneumatic muscle pairs. Methods Three healthy males were fitted with custom KAFOs equipped with artificial pneumatic muscles to power ankle plantar flexion/dorsiflexion and knee extension/flexion. Subjects walked over ground at 1.25 m/s under four conditions without extensive practice: 1 without wearing the orthosis, 2 wearing the orthosis with artificial muscles turned off, 3 wearing the orthosis activated under direct proportional myoelectric control, and 4 wearing the orthosis activated under proportional myoelectric control with flexor inhibition produced by leg extensor muscle activation. We collected joint kinematics, ground reaction forces, electromyography, and orthosis kinetics. Results The KAFO produced ~22%–33% of the peak knee flexor moment, ~15%–33% of the peak extensor moment, ~42%–46% of the peak plantar flexor moment, and ~83%–129% of the peak dorsiflexor moment during normal walking. With flexor inhibition produced by leg extensor muscle activation, ankle (Pearson r-value = 0.74 ± 0.04 and knee ( r = 0.95 ± 0.04 joint kinematic profiles were more similar to the without orthosis condition compared to when there was no flexor inhibition (r = 0.49 ± 0.13 for ankle, p = 0.05, and r = 0.90 ± 0.03 for knee, p = 0.17. Conclusion The proportional myoelectric control with flexor inhibition allowed for a more normal gait than direct proportional myoelectric control. The current

  9. A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition

    Science.gov (United States)

    Sawicki, Gregory S; Ferris, Daniel P

    2009-01-01

    Background The goal of this study was to test the mechanical performance of a prototype knee-ankle-foot orthosis (KAFO) powered by artificial pneumatic muscles during human walking. We had previously built a powered ankle-foot orthosis (AFO) and used it effectively in studies on human motor adaptation, locomotion energetics, and gait rehabilitation. Extending the previous AFO to a KAFO presented additional challenges related to the force-length properties of the artificial pneumatic muscles and the presence of multiple antagonistic artificial pneumatic muscle pairs. Methods Three healthy males were fitted with custom KAFOs equipped with artificial pneumatic muscles to power ankle plantar flexion/dorsiflexion and knee extension/flexion. Subjects walked over ground at 1.25 m/s under four conditions without extensive practice: 1) without wearing the orthosis, 2) wearing the orthosis with artificial muscles turned off, 3) wearing the orthosis activated under direct proportional myoelectric control, and 4) wearing the orthosis activated under proportional myoelectric control with flexor inhibition produced by leg extensor muscle activation. We collected joint kinematics, ground reaction forces, electromyography, and orthosis kinetics. Results The KAFO produced ~22%–33% of the peak knee flexor moment, ~15%–33% of the peak extensor moment, ~42%–46% of the peak plantar flexor moment, and ~83%–129% of the peak dorsiflexor moment during normal walking. With flexor inhibition produced by leg extensor muscle activation, ankle (Pearson r-value = 0.74 ± 0.04) and knee ( r = 0.95 ± 0.04) joint kinematic profiles were more similar to the without orthosis condition compared to when there was no flexor inhibition (r = 0.49 ± 0.13 for ankle, p = 0.05, and r = 0.90 ± 0.03 for knee, p = 0.17). Conclusion The proportional myoelectric control with flexor inhibition allowed for a more normal gait than direct proportional myoelectric control. The current orthosis design

  10. The Effects of Varying Ankle Foot Orthosis Stiffness on Gait in Children with Spastic Cerebral Palsy Who Walk with Excessive Knee Flexion

    NARCIS (Netherlands)

    Kerkum, Yvette L.; Buizer, Annemieke I.; van den Noort, Josien C.; Becher, Jules G.; Harlaar, Jaap; Brehm, Merel-Anne

    2015-01-01

    Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A

  11. The Effects of Varying Ankle Foot Orthosis Stiffness on Gait in Children with Spastic Cerebral Palsy Who Walk with Excessive Knee Flexion

    NARCIS (Netherlands)

    Kerkum, Y.L.; Buizer, A.I.; van den Noort, J.C.; Becher, J.G.; Harlaar, J.; Brehm, M.A.

    2015-01-01

    Introduction: Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off

  12. Ankle and knee kinetics between strike patterns at common training speeds in competitive male runners.

    Science.gov (United States)

    Kuhman, Daniel; Melcher, Daniel; Paquette, Max R

    2016-01-01

    The purpose of this study was to investigate the interaction of foot strike and common speeds on sagittal plane ankle and knee joint kinetics in competitive rear foot strike (RFS) runners when running with a RFS pattern and an imposed forefoot strike (FFS) pattern. Sixteen competitive habitual male RFS runners ran at two different speeds (i.e. 8 and 6 min mile(-1)) using their habitual RFS and an imposed FFS pattern. A repeated measures analysis of variance was used to assess a potential interaction between strike pattern and speed for selected ground reaction force (GRF) variables and, sagittal plane ankle and knee kinematic and kinetic variables. No foot strike and speed interaction was observed for any of the kinetic variables. Habitual RFS yielded a greater loading rate of the vertical GRF, peak ankle dorsiflexor moment, peak knee extensor moment, peak knee eccentric extensor power, peak dorsiflexion and sagittal plane knee range of motion compared to imposed FFS. Imposed FFS yielded greater maximum vertical GRF, peak ankle plantarflexor moment, peak ankle eccentric plantarflexor power and sagittal plane ankle ROM compared to habitual RFS. Consistent with previous literature, imposed FFS in habitual RFS reduces eccentric knee extensor and ankle dorsiflexor involvement but produce greater eccentric ankle plantarflexor action compared to RFS. These acute differences between strike patterns were independent of running speeds equivalent to typical easy and hard training runs in competitive male runners. Current findings along with previous literature suggest differences in lower extremity kinetics between habitual RFS and imposed FFS running are consistent among a variety of runner populations.

  13. Lyme Disease Manifestations in the Foot and Ankle: A Retrospective Case Series.

    Science.gov (United States)

    Miller, Jason R; Dunn, Karl W; Braccia, Domenick; Ciliberti, Louis J; Becker, Dina K; Hollinger, Joshua K; Brand, Shelley M

    Lyme disease is the result of Borrelia burgdorferi bacterial infection after exposure from a tick bite. A pathognomonic finding in early-stage Lyme disease is an expanding, red macular ring known as erythema migrans. Lyme arthritis is a late-stage manifestation of this disease, affecting the large, weightbearing joints with intermittent pain and swelling. The existing data on Lyme disease and subsequent arthritis have reported manifestations in the lower extremity, primarily in the knee and ankle and less commonly the small joints of the foot. We present a retrospective case series of 11 cases of painful arthritis in the foot and ankle with confirmatory Lyme disease testing. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of a Powered Ankle-Foot Prosthesis during Slope Ascent Gait.

    Directory of Open Access Journals (Sweden)

    Christopher A Rábago

    Full Text Available Passive prosthetic feet lack active plantarflexion and push-off power resulting in gait deviations and compensations by individuals with transtibial amputation (TTA during slope ascent. We sought to determine the effect of active ankle plantarflexion and push-off power provided by a powered prosthetic ankle-foot (PWR on lower extremity compensations in individuals with unilateral TTA as they walked up a slope. We hypothesized that increased ankle plantarflexion and push-off power would reduce compensations commonly observed with a passive, energy-storing-returning prosthetic ankle-foot (ESR. We compared the temporal spatial, kinematic, and kinetic measures of ten individuals with TTA (age: 30.2 ± 5.3 yrs to matched abled-bodied (AB individuals during 5° slope ascent. The TTA group walked with an ESR and separately with a PWR. The PWR produced significantly greater prosthetic ankle plantarflexion and push-off power generation compared to an ESR and more closely matched AB values. The PWR functioned similar to a passive ESR device when transitioning onto the prosthetic limb due to limited prosthetic dorsiflexion, which resulted in similar deviations and compensations. In contrast, when transitioning off the prosthetic limb, increased ankle plantarflexion and push-off power provided by the PWR contributed to decreased intact limb knee extensor power production, lessening demand on the intact limb knee.

  15. Evaluation of a Powered Ankle-Foot Prosthesis during Slope Ascent Gait.

    Science.gov (United States)

    Rábago, Christopher A; Aldridge Whitehead, Jennifer; Wilken, Jason M

    2016-01-01

    Passive prosthetic feet lack active plantarflexion and push-off power resulting in gait deviations and compensations by individuals with transtibial amputation (TTA) during slope ascent. We sought to determine the effect of active ankle plantarflexion and push-off power provided by a powered prosthetic ankle-foot (PWR) on lower extremity compensations in individuals with unilateral TTA as they walked up a slope. We hypothesized that increased ankle plantarflexion and push-off power would reduce compensations commonly observed with a passive, energy-storing-returning prosthetic ankle-foot (ESR). We compared the temporal spatial, kinematic, and kinetic measures of ten individuals with TTA (age: 30.2 ± 5.3 yrs) to matched abled-bodied (AB) individuals during 5° slope ascent. The TTA group walked with an ESR and separately with a PWR. The PWR produced significantly greater prosthetic ankle plantarflexion and push-off power generation compared to an ESR and more closely matched AB values. The PWR functioned similar to a passive ESR device when transitioning onto the prosthetic limb due to limited prosthetic dorsiflexion, which resulted in similar deviations and compensations. In contrast, when transitioning off the prosthetic limb, increased ankle plantarflexion and push-off power provided by the PWR contributed to decreased intact limb knee extensor power production, lessening demand on the intact limb knee.

  16. PEMF as treatment for delayed healing of foot and ankle arthrodesis.

    Science.gov (United States)

    Saltzman, Charles; Lightfoot, Andrew; Amendola, Annunziato

    2004-11-01

    Arthrodesis is the most common surgical treatment for foot and ankle arthritis. In adults, these procedures are associated with a 5% to 10% rate of nonunion. Pulsed electromagnetic field (PEMF) stimulation was approved by the Federal Drug Administration (FDA) for treatment of delayed unions after long-bone fractures and joint arthrodesis. The purpose of this study was to examine the results of PEMF treatment for delayed healing after foot and ankle arthrodesis. Three hundred and thirty-four foot and ankle arthrodeses were done. Nineteen resulted in delayed unions that were treated with a protocol of immobilization, limited weightbearing, and PEMF stimulation for a median of 7 (range 5 to 27) months. All patients were followed clinically and radiographically. The use of PEMF, immobilization, and limited weightbearing to treat delayed union after foot and ankle arthrodesis was successful in 5 of 19 (26%) patients. Of the other 14 patients with nonunions, nine had revision surgery with autogenous grafting, continued immobilization, and PEMF stimulation. Seven of these eventually healed at a median of 5.5 (range 2 to 26) months and two did not heal. One patient had a below-knee amputation, and four refused further treatment. The protocol of PEMF, immobilization, and limited weightbearing had a relatively low success rate in this group of patients. We no longer use this protocol alone to treat delayed union after foot and ankle arthrodesis.

  17. Foot, leg, and ankle swelling

    Science.gov (United States)

    Swelling of the ankles - feet - legs; Ankle swelling; Foot swelling; Leg swelling; Edema - peripheral; Peripheral edema ... Foot, leg, and ankle swelling is common when the person also: Is overweight Has a blood clot in the leg Is older Has ...

  18. Enhanced spinal excitation from ankle flexors to knee extensors during walking in stroke patients

    DEFF Research Database (Denmark)

    Achache, V.; Mazevet, D.; Iglesias, C.

    2010-01-01

    : The spinal, presumed group II, excitation from ankle dorsiflexors to knee extensors is particularly enhanced during post-stroke walking probably due to plastic adaptations in the descending control. SIGNIFICANCE: This adaptation may help to stabilize the knee in early stance when the patients have recover......OBJECTIVES: It is still unclear to what an extent altered reflex activity contributes to gait deficit following stroke. Spinal group I and group II excitations from ankle dorsiflexors to knee extensors were investigated during post-stroke walking. METHODS: Electrical stimulation was applied...... ankle dorsiflexor functions....

  19. What Is a Foot and Ankle Surgeon?

    Science.gov (United States)

    ... A A | Print | Share What is a Foot & Ankle Surgeon? Foot and ankle surgeons are the surgical ... every age. What education has a foot and ankle surgeon received? After completing undergraduate education, the foot ...

  20. Mobile ankle and knee perturbator.

    Science.gov (United States)

    Andersen, Jacob Buus; Sinkjaer, Thomas

    2003-10-01

    A mobile ankle and knee perturbator has been developed. It consists of a functional joint with an integrated clutch. Four Bowden wires connect the joint to a powerful motor and a double pneumatic cylinder. When needed during any time of the gait cycle, it is possible to impose an ankle rotation by engaging the clutch and rotating the ankle or knee joint with a predefined displacement. The system is designed to investigate electrophysiological and biomechanical features of the human ankle or knee joint during gait.

  1. Deep-vein thrombosis prophylaxis in foot and ankle surgery: what is the current state of practice?

    Science.gov (United States)

    Shah, Kalpesh; Thevendran, Gowreeson; Younger, Alastair; Pinney, Stephen J

    2015-04-01

    When contemplating thromboprophylaxis for patients undergoing elective foot and ankle surgery the potential for complications secondary to venous thromboembolism (VTE) must be balanced against the cost, risk, and effectiveness of prophylactic treatment. The incidence of pulmonary embolism (PE) following foot and ankle surgery is considerably lower than after hip or knee surgery. The purpose of this study was to assess current trends in practice regarding VTE prophylaxis among expert orthopaedic foot and ankle surgeons. An e-mail-based survey of active AOFAS (American Orthopaedic Foot and Ankle Society) committee members was conducted (n = 100). Surgeons were questioned as to their use, type, and duration of thromboprophylaxis following elective ankle fusion surgery. Scenarios included the following: (1) A 50-year-old woman with no risk factors; (2) a 50-year-old woman with a history of PE; and (3) a 35-year-old woman actively using birth control pills (BCPs). The response rate for the survey was 80% (80/100). Replies regarding the use of thromboprophylaxis were as follows: (1) in the absence of risk factors, 57% of respondents (45/80) answered, "No prophylaxis required"; (2) for the scenario in which the patient had experienced a previous PE, 97.5% of respondents (78/80) answered, "Yes" to prophylaxis use; (3) for the scenario in which the patient was on BCP, 61.3% of respondents (49/80) stated that they would give some type of thromboprophylaxis. The most commonly recommended methods of prophylaxis were aspirin, 49% (24/49), and low-molecular-weight heparin, 47% (23/49). The recommended length of time for thromboprophylaxis varied widely, from 1 day to more than 6 weeks. . There remains wide variation in the practice of deep-vein thrombosis thromboprophylaxis within the foot and ankle community. Because risks for foot and ankle patients differ from those in the well-studied areas of hip and knee, specific guidelines are needed for foot and ankle surgery. Level V

  2. Optimising Ankle Foot Orthoses for children with Cerebral Palsy walking with excessive knee flexion to improve their mobility and participation; protocol of the AFO-CP study

    NARCIS (Netherlands)

    Kerkum, Y.L.; Harlaar, J.; Buizer, A.I.; van den Noort, J.C.; Becher, J.G.; Brehm, M.A.

    2013-01-01

    Background: Ankle-Foot-Orthoses with a ventral shell, also known as Floor Reaction Orthoses (FROs), are often used to reduce gait-related problems in children with spastic cerebral palsy (SCP), walking with excessive knee flexion. However, current evidence for the effectiveness (e.g. in terms of

  3. Optimising Ankle Foot Orthoses for children with cerebral palsy walking with excessive knee flexion to improve their mobility and participation; protocol of the AFO-CP study

    NARCIS (Netherlands)

    Kerkum, Yvette L.; Harlaar, Jaap; Buizer, Annemieke I.; van den Noort, Josien C.; Becher, Jules G.; Brehm, Merel-Anne

    2013-01-01

    Ankle-Foot-Orthoses with a ventral shell, also known as Floor Reaction Orthoses (FROs), are often used to reduce gait-related problems in children with spastic cerebral palsy (SCP), walking with excessive knee flexion. However, current evidence for the effectiveness (e.g. in terms of walking energy

  4. Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis.

    Science.gov (United States)

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2017-01-01

    There are unanswered questions about knee-ankle alignment after total knee arthroplasty (TKA) for varus and valgus osteoarthritis (OA) of the knee. The aim of this retrospective study was to assess knee-ankle alignment after TKA. The study consisted of 149 patients who had undergone TKA due to varus and valgus knee OA. The alignment and angles in the selected knees and ankles were measured on full-length standing anteroposterior radiographs, both pre-operatively and post-operatively. The paired t-test and Pearson's correlation tests were used for statistical analysis. The results showed that ankle alignment correlated with knee alignment both pre-operatively and postoperatively (Pknee was corrected (Pknee-ankle alignment on the non-operative side (P>0.05). These findings indicated that routine TKA could correct the varus or valgus deformity of a knee, and improve the tilt of the ankle. Ankle alignment correlated with knee alignment both pre-operatively and postoperatively. Both pre-operative knee and ankle malalignment can be simultaneously corrected following TKA. Level III. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. The foot and ankle

    International Nuclear Information System (INIS)

    Berquist, T.H.

    1985-01-01

    Imaging of the foot and ankle can be difficult because of the complex anatomy. Familiarity with the bony and ligamentous anatomy is essential for proper evaluation of radiographic findings. Therefore, pertinent anatomy is discussed as it applies to specific injuries. Special views, tomography, arthrography, and other techniques may be indicated for complete evaluation of foot and ankle trauma

  6. Redistribution of Mechanical Work at the Knee and Ankle Joints During Fast Running in Minimalist Shoes.

    Science.gov (United States)

    Fuller, Joel T; Buckley, Jonathan D; Tsiros, Margarita D; Brown, Nicholas A T; Thewlis, Dominic

    2016-10-01

    Minimalist shoes have been suggested as a way to alter running biomechanics to improve running performance and reduce injuries. However, to date, researchers have only considered the effect of minimalist shoes at slow running speeds. To determine if runners change foot-strike pattern and alter the distribution of mechanical work at the knee and ankle joints when running at a fast speed in minimalist shoes compared with conventional running shoes. Crossover study. Research laboratory. Twenty-six trained runners (age = 30.0 ± 7.9 years [age range, 18-40 years], height = 1.79 ± 0.06 m, mass = 75.3 ± 8.2 kg, weekly training distance = 27 ± 15 km) who ran with a habitual rearfoot foot-strike pattern and had no experience running in minimalist shoes. Participants completed overground running trials at 18 km/h in minimalist and conventional shoes. Sagittal-plane kinematics and joint work at the knee and ankle joints were computed using 3-dimensional kinematic and ground reaction force data. Foot-strike pattern was classified as rearfoot, midfoot, or forefoot strike based on strike index and ankle angle at initial contact. We observed no difference in foot-strike classification between shoes (χ 2 1 = 2.29, P = .13). Ankle angle at initial contact was less (2.46° versus 7.43°; t 25 = 3.34, P = .003) and strike index was greater (35.97% versus 29.04%; t 25 = 2.38, P = .03) when running in minimalist shoes compared with conventional shoes. We observed greater negative (52.87 J versus 42.46 J; t 24 = 2.29, P = .03) and positive work (68.91 J versus 59.08 J; t 24 = 2.65, P = .01) at the ankle but less negative (59.01 J versus 67.02 J; t 24 = 2.25, P = .03) and positive work (40.37 J versus 47.09 J; t 24 = 2.11, P = .046) at the knee with minimalist shoes compared with conventional shoes. Running in minimalist shoes at a fast speed caused a redistribution of work from the knee to the ankle joint. This finding suggests that runners changing from conventional to minimalist

  7. Effects of ankle-foot orthoses on mediolateral foot-placement ability during post-stroke gait.

    Science.gov (United States)

    Zissimopoulos, Angelika; Fatone, Stefania; Gard, Steven

    2015-10-01

    Accurate and precise mediolateral foot placement is important for balance during gait, but is impaired post stroke. Mediolateral foot placement may be improved with ankle-foot orthosis use. The purpose of this study was to determine whether an ankle-foot orthosis improves mediolateral foot-placement ability during post-stroke ambulation. Crossover trial with randomized order of conditions tested. The accuracy and precision of mediolateral foot placement was quantified while subjects targeted four different randomized step widths. Subjects were tested with and without their regular non-rigid ankle-foot orthosis in two separate visits (order randomized). While ankle-foot orthosis use corrected foot and ankle alignment (i.e. significantly decreased mid-swing plantar flexion, p = 0.000), effects of ankle-foot orthosis use on hip hiking (p = 0.545), circumduction (p = 0.179), coronal plane hip range of motion (p = 0.06), and mediolateral foot-placement ability (p = 0.537) were not significant. While ankle-foot orthosis-mediated equinovarus correction of the affected foot and ankle was not associated with improved biomechanics of walking (i.e. proximal ipsilateral hip kinematics or mediolateral foot-placement ability), it may affect other aspects of balance that were not tested in this study (e.g. proprioception, cerebellar, vestibular, and cognitive mechanisms). Studies that investigate the effect of ankle-foot orthosis on gait can help advance stroke rehabilitation by documenting the specific gait benefits of ankle-foot orthosis use. In this study, we investigated the effect of ankle-foot orthosis use on mediolateral foot-placement ability, an aspect of gait important for maintaining balance. © The International Society for Prosthetics and Orthotics 2014.

  8. Foot and ankle problems in Thai monks.

    Science.gov (United States)

    Vaseenon, Tanawat; Wattanarojanaporn, Thongaek; Intharasompan, Piyapong; Theeraamphon, Nipon; Auephanviriyakul, Sansanee; Phisitkul, Phinit

    2015-01-01

    Foot and ankle problems in Thai monks have not been explored. This is an unshod population, and its members have a unique lifestyle living among others in our modern era. Beginning at their ordainment, they follow strict rules about barefoot walking, the amount of daily walking, and their sitting position, practices that theoretically can increase their risk of developing foot and ankle problems. To evaluate the prevalence ofcommon foot and ankle problems in Thai monks. A cross-sectional survey was conducted in combination with foot and ankle examinations of monks living in northern Thailand Foot morphology was examined using a Harris mat footprint. Results of the interviews and the foot and ankle examinations were evaluated. Two hundred and nine monks from 28 temples were included in this study. Common foot and ankle problems found included callosity (70.8%), toe deformities (18.2%), plantar fasciitis (13.4%), metatarsalgia (3.8%), and numbness (2.9%). Callosity and toe deformities were associated with prolonged barefoot walking over extended periods since ordainment (p < 0.05). The callosity was found on the forefoot (47.3%), lateral malleolus (40.7%), and heel (12%). Arch types were considered normal in 66.4% of cases, high in 21.6%, and low in 12%. No association was found between arch type and foot and ankle problems. Callosity and toe deformity were the most common foot and ankle problems found in Thai monks, especially those with prolonged period of barefoot walking and long-term duration ofordainment. The unique pattern of walking and sitting of Thai monks may have contributed to the development of those feet and ankle problems.

  9. Pre-impact lower extremity posture and brake pedal force predict foot and ankle forces during an automobile collision.

    Science.gov (United States)

    Hardin, E C; Su, A; van den Bogert, A J

    2004-12-01

    The purpose of this study was to determine how a driver's foot and ankle forces during a frontal vehicle collision depend on initial lower extremity posture and brake pedal force. A 2D musculoskeletal model with seven segments and six right-side muscle groups was used. A simulation of a three-second braking task found 3647 sets of muscle activation levels that resulted in stable braking postures with realistic pedal force. These activation patterns were then used in impact simulations where vehicle deceleration was applied and driver movements and foot and ankle forces were simulated. Peak rearfoot ground reaction force (F(RF)), peak Achilles tendon force (FAT), peak calcaneal force (F(CF)) and peak ankle joint force (F(AJ)) were calculated. Peak forces during the impact simulation were 476 +/- 687 N (F(RF)), 2934 +/- 944 N (F(CF)) and 2449 +/- 918 N (F(AJ)). Many simulations resulted in force levels that could cause fractures. Multivariate quadratic regression determined that the pre-impact brake pedal force (PF), knee angle (KA) and heel distance (HD) explained 72% of the variance in peak FRF, 62% in peak F(CF) and 73% in peak F(AJ). Foot and ankle forces during a collision depend on initial posture and pedal force. Braking postures with increased knee flexion, while keeping the seat position fixed, are associated with higher foot and ankle forces during a collision.

  10. Modeling and stress analyses of a normal foot-ankle and a prosthetic foot-ankle complex.

    Science.gov (United States)

    Ozen, Mustafa; Sayman, Onur; Havitcioglu, Hasan

    2013-01-01

    Total ankle replacement (TAR) is a relatively new concept and is becoming more popular for treatment of ankle arthritis and fractures. Because of the high costs and difficulties of experimental studies, the developments of TAR prostheses are progressing very slowly. For this reason, the medical imaging techniques such as CT, and MR have become more and more useful. The finite element method (FEM) is a widely used technique to estimate the mechanical behaviors of materials and structures in engineering applications. FEM has also been increasingly applied to biomechanical analyses of human bones, tissues and organs, thanks to the development of both the computing capabilities and the medical imaging techniques. 3-D finite element models of the human foot and ankle from reconstruction of MR and CT images have been investigated by some authors. In this study, data of geometries (used in modeling) of a normal and a prosthetic foot and ankle were obtained from a 3D reconstruction of CT images. The segmentation software, MIMICS was used to generate the 3D images of the bony structures, soft tissues and components of prosthesis of normal and prosthetic ankle-foot complex. Except the spaces between the adjacent surface of the phalanges fused, metatarsals, cuneiforms, cuboid, navicular, talus and calcaneus bones, soft tissues and components of prosthesis were independently developed to form foot and ankle complex. SOLIDWORKS program was used to form the boundary surfaces of all model components and then the solid models were obtained from these boundary surfaces. Finite element analyses software, ABAQUS was used to perform the numerical stress analyses of these models for balanced standing position. Plantar pressure and von Mises stress distributions of the normal and prosthetic ankles were compared with each other. There was a peak pressure increase at the 4th metatarsal, first metatarsal and talus bones and a decrease at the intermediate cuneiform and calcaneus bones, in

  11. Gait comparison of subjects with hemiplegia walking unbraced, with ankle-foot orthosis, and with Air-Stirrup brace.

    Science.gov (United States)

    Burdett, R G; Borello-France, D; Blatchly, C; Potter, C

    1988-08-01

    The effects of the Air-Stirrup (AS) standard ankle brace on the gait of 19 subjects with hemiplegia resulting from a cerebrovascular accident who exhibited excessive subtalar joint motion were studied. Videotaped trials and footprint analyses were used to measure subjects' hip, knee, and ankle sagittal plane angles; inversion and eversion of the calcaneus; and time-distance gait characteristics. A one-way analysis of variance for repeated measures was used to compare the gait of 19 subjects with the AS brace and unbraced and 11 subjects with the AS brace, unbraced, and with an ankle-foot orthosis. The AS brace was associated with more calcaneal stability during standing than the unbraced condition. The ankle-foot orthosis was associated with less plantar flexion at foot-strike than either the AS brace or unbraced condition. Both the AS brace and the ankle-foot orthosis were associated with less mid-swing plantar flexion and increased step length on the paretic side compared with no brace. These results support the effectiveness of the AS brace in controlling inversion and eversion instability in patients with hemiplegia.

  12. Foot and ankle problems in Muay Thai kickboxers.

    Science.gov (United States)

    Vaseenon, Tanawat; Intharasompan, Piyapong; Wattanarojanapom, Thongaek; Theeraamphon, Nipon; Auephanviriyakul, Sansanee; Phisitkul, Phinit

    2015-01-01

    Muay Thai kickboxing is a common sport that uses the foot and ankle in fighting. Muay Thai kickboxing trainees usually receive training in Thailand Foot and ankle problems in this group ofpeople who usually train barefoot remain unexplored To evaluate the prevalence of common foot and ankle problems in Muay Thai kick boxers. The present study is a cross-sectional survey of Muay Thai kick boxers practicing in northern Thailand. Interviews were conducted and foot and ankle examinations were evaluated Foot morphology was examined using a Harris mat footprint. One hundred and twenty-three Muay Thai kickbox ersinnine training gyms were included in this study. Common foot and ankle problems found in the Muay Thai kick boxers were callosity (59%), gastrocnemius contracture (57%), toe deformities (49.3%), wounds (10%) and heel pain (9%). Callosity was most commonly found on the forefoot (77.5%), on the plantar first metatarsal (55.3%) and on the big toe (33.3%). An association was found between a tight heel cord and a history of foot injury with prolonged periods of weekly training. Toe deformities such as hallux rigidus (37.6%) were also associated with prolonged periods of training (p = 0.001). No correlation was found between type of foot arch and foot and ankle problems. Plantar forefoot callosities and wounds as well as toe deformities including tight heel cords are some of the foot and ankle problems commonly found in Muay Thai kick boxers. They are associated with prolonged periods of barefoot training. The unique pattern of training and of the kicks in Muay Thai might be a path mechanism, leading to the development of foot and ankle problems.

  13. Benign and malignant tumors of the foot and ankle

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Adam D.; Datir, Abhijit; Langley, Travis [Emory University Hospital, Department of Radiology, Section of Musculoskeletal Imaging, Atlanta, GA (United States); Tresley, Jonathan [University of Wisconsin, Department of Radiology, Madison, WI (United States); Clifford, Paul D.; Jose, Jean; Subhawong, Ty K. [University of Miami, Department of Radiology, Miami, FL (United States)

    2016-03-15

    Pain and focal masses in the foot and ankle are frequently encountered and often initiate a workup including imaging. It is important to differentiate benign lesions from aggressive benign or malignant lesions. In this review, multiple examples of osseous and soft tissue tumors of the foot and ankle will be presented. Additionally, the compartmental anatomy of the foot and ankle will be discussed in terms of its relevance for percutaneous biopsy planning and eventual surgery. Finally, a general overview of the surgical management of benign, benign aggressive and malignant tumors of the foot and ankle will be discussed. (orig.)

  14. Effects of total knee arthroplasty on ankle alignment in patients with varus gonarthrosis: Do we sacrifice ankle to the knee?

    Science.gov (United States)

    Gursu, Sarper; Sofu, Hakan; Verdonk, Peter; Sahin, Vedat

    2016-08-01

    Total knee arthroplasty is one of the most commonly preferred surgical methods in the treatment of patients with varus gonarthrosis. In this study, we aimed to evaluate the radiological changes observed in the ankles after total knee arthroplasty. Between May 2012 and June 2013, 80 knees of 78 patients with varus deformity over 10° underwent total knee arthroplasty. For each patient, full-leg standing radiographs were obtained pre- and post-operatively. Mechanical and anatomical axes (HKA and AA), lateral distal femoral angle, medial proximal tibial angle, lateral distal tibial angle (LDTA), ankle joint line orientation angle (AJOA), tibial plafond talus angle (PTA) and talar shift were measured for each patient both pre- and post-operatively. Pre-operatively, the mean HKA was 16.6° and the mean AA was 10.41°, both in favour of varus alignment. Post-operatively, the mean HKA decreased to 3.6° and the mean AA to -2.1. The mean LDTA was 87.3°. Before the operation, the mean AJOA was -7.6°, opening to the medial aspect of the ankle, and it was 0.04° after the operation and opening to the lateral aspect (p < 0.05). Our study reveals the changes occurring in the ankle after acute correction of long-standing varus deformity of the knee using total knee arthroplasty. In cases undergoing knee arthroplasty, effect of the acute change in the alignment of the knee on the ankle should be taken into consideration and the amount of correction should be calculated carefully in order not to damage the alignment of the ankle. IV.

  15. Prospective study of ankle and foot fractures in elderly women

    Directory of Open Access Journals (Sweden)

    Yadagiri Surender Rao

    2015-01-01

    Full Text Available The epidemiology of ankle fractures in old people is changing as time passes on. The incidence of ankle fractures increases with advancing age. The study conducted was among a rural popula-tion which comprised of 68 women (32 women with ankle fractures & 36 women with foot fractures. Patients studied were in the age group more than 50 years. The study highlights the etiological & risk factors for fractures of ankle & foot. The commonest ankle fracture was the lateral malleolar fracture & the commonest foot fracture was the 5th Metatarsal fracture. Diabetes is a risk factor which increases the occurrence of ankle and foot injuries.

  16. Altered Knee and Ankle Kinematics During Squatting in Those With Limited Weight-Bearing–Lunge Ankle-Dorsiflexion Range of Motion

    Science.gov (United States)

    Dill, Karli E.; Begalle, Rebecca L.; Frank, Barnett S.; Zinder, Steven M.; Padua, Darin A.

    2014-01-01

    Context: Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. Objective: To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Design: Cross-sectional study. Setting: Sports medicine research laboratory. Patients or Other Participants: Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Main Outcome Measure(s): Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. Results: We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Conclusions: Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during

  17. Effects on foot external rotation of the modified ankle-foot orthosis on post-stroke hemiparetic gait.

    Science.gov (United States)

    Kim, Ha Jeong; Chun, Min Ho; Kim, Hong Min; Kim, Bo Ryun

    2013-08-01

    To evaluate the effects of heel-opened ankle foot orthosis (HOAFO) on hemiparetic gait after stroke, especially on external foot rotation, and to compare the effects of HOAFO with conventional plastic-AFO (pAFO) and barefoot during gait. This cross-over observational study involved 15 hemiparetic patients with external rotation of the affected foot. All subjects were able to walk independently, regardless of their usual use of a single cane, and had a less than fair-grade in ankle dorsiflexion power. Each patient was asked to walk in three conditions with randomized sequences: 1) barefoot, 2) with a pAFO, and 3) with an HOAFO. Their gait patterns were analyzed using a motion analysis system. Fifteen patients consisted of nine males and six females. On gait analysis, hip and foot external rotation were significantly greater in pAFO (-3.35° and -23.68°) than in barefoot and HOAFO conditions (pexternal rotation compared with pAFO; although there was no significant difference between HOAFO and barefoot walking. Walking speed and percentage of single limb support were significantly greater for HOAFO than in barefoot walking. HOAFO was superior to pAFO in reducing hip and foot external rotation during the stance phase in patients with post-stroke hemiparesis. HOAFO may, therefore, be useful in patients with excessive external rotation of the foot during conventional pAFO.

  18. A three-dimensional model to assess the effect of ankle joint axis misalignments in ankle-foot orthoses.

    Science.gov (United States)

    Fatone, Stefania; Johnson, William Brett; Tucker, Kerice

    2016-04-01

    Misalignment of an articulated ankle-foot orthosis joint axis with the anatomic joint axis may lead to discomfort, alterations in gait, and tissue damage. Theoretical, two-dimensional models describe the consequences of misalignments, but cannot capture the three-dimensional behavior of ankle-foot orthosis use. The purpose of this project was to develop a model to describe the effects of ankle-foot orthosis ankle joint misalignment in three dimensions. Computational simulation. Three-dimensional scans of a leg and ankle-foot orthosis were incorporated into a link segment model where the ankle-foot orthosis joint axis could be misaligned with the anatomic ankle joint axis. The leg/ankle-foot orthosis interface was modeled as a network of nodes connected by springs to estimate interface pressure. Motion between the leg and ankle-foot orthosis was calculated as the ankle joint moved through a gait cycle. While the three-dimensional model corroborated predictions of the previously published two-dimensional model that misalignments in the anterior -posterior direction would result in greater relative motion compared to misalignments in the proximal -distal direction, it provided greater insight showing that misalignments have asymmetrical effects. The three-dimensional model has been incorporated into a freely available computer program to assist others in understanding the consequences of joint misalignments. Models and simulations can be used to gain insight into functioning of systems of interest. We have developed a three-dimensional model to assess the effect of ankle joint axis misalignments in ankle-foot orthoses. The model has been incorporated into a freely available computer program to assist understanding of trainees and others interested in orthotics. © The International Society for Prosthetics and Orthotics 2014.

  19. Ankle and knee biomechanics during normal walking following ankle plantarflexor fatigue.

    Science.gov (United States)

    Hunt, Michael A; Hatfield, Gillian L

    2017-08-01

    The purpose of this study was to investigate the immediate effects of unilateral ankle plantarflexor fatigue on bilateral knee and ankle biomechanics during gait. Lower leg kinematics, kinetics, and muscle activation were assessed before and after an ankle plantarflexor fatiguing protocol in 31 healthy individuals. Fatigue (defined as >10% reduction in maximal isometric ankle plantarflexor torque production and a downward shift in the median power frequency of both heads of the gastrocnemius muscle of the fatigued limb) was achieved in 18 individuals, and only their data were used for analysis purposes. Compared to pre-fatigue walking trials, medial gastrocnemius activity was significantly reduced in the study (fatigued) limb. Other main changes following fatigue included significantly more knee flexion during loading, and an associated larger external knee flexion moment in the study limb. At the ankle joint, participants exhibited significantly less peak plantarflexion (occurring at toe-off) with fatigue. No significant differences were observed in the contralateral (non-fatigued) limb. Findings from this study indicate that fatigue of the ankle plantarflexor muscle does not produce widespread changes in gait biomechanics, suggesting that small to moderate changes in maximal ankle plantarflexor force production capacity (either an increase or decrease) will not have a substantial impact on normal lower limb functioning during gait. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Validity and reliability of Thai version of the Foot and Ankle Outcome Score in patients with arthritis of the foot and ankle.

    Science.gov (United States)

    Angthong, Chayanin

    2016-12-01

    Although the Foot and Ankle Outcome Score (FAOS) is commonly used in several languages for a variety of foot disorders, it has not been validated specifically for foot and ankle arthritic conditions. The aims of the present study were to translate the original English FAOS into Thai and to evaluate the validity and reliability of the Thai version of the FAOS for the foot and ankle arthritic conditions. The original FAOS was translated into Thai using forward-backward translation. The Thai FAOS and validated Thai Short Form-36 (SF-36 ® ) questionnaires were distributed to 44 Thai patients suffering from arthritis of the foot and ankle to complete. For validation, Thai FAOS scores were correlated with SF-36 scores. Test-retest reliability and internal consistency were also analyzed in this study. The Thai FAOS score demonstrated sufficient correlation with SF-36 total score in Pain (Pearson's correlation coefficient (r)=0.45, p=0.002), Symptoms (r=0.45, p=0.002), Activities of Daily Living (ADL) (r=0.47, p=0.001), and Quality of Life (QOL) (r=0.38, p=0.011) subscales. The Sports and Recreational Activities (Sports & Rec) subscale did not correlate significantly with the SF-36 ® (r=0.20, p=0.20). Cronbach's alpha, a measure of internal consistency, for the five subscales was as follows: Pain, 0.94 (pvalidity for the evaluation of foot and ankle arthritis. Although reliability was satisfactory for the major subscale ADL, it was not sufficient for the minor subscales. Our findings suggest that it can be used as a disease-specific instrument to evaluate foot and ankle arthritis and can complement other reliable outcome surveys. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  1. A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop

    Directory of Open Access Journals (Sweden)

    Chin Robin

    2009-06-01

    Full Text Available Abstract Background A self-contained, self-controlled, pneumatic power harvesting ankle-foot orthosis (PhAFO to manage foot-drop was developed and tested. Foot-drop is due to a disruption of the motor control pathway and may occur in numerous pathologies such as stroke, spinal cord injury, multiple sclerosis, and cerebral palsy. The objectives for the prototype PhAFO are to provide toe clearance during swing, permit free ankle motion during stance, and harvest the needed power with an underfoot bellow pump pressurized during the stance phase of walking. Methods The PhAFO was constructed from a two-part (tibia and foot carbon composite structure with an articulating ankle joint. Ankle motion control was accomplished through a cam-follower locking mechanism actuated via a pneumatic circuit connected to the bellow pump and embedded in the foam sole. Biomechanical performance of the prototype orthosis was assessed during multiple trials of treadmill walking of an able-bodied control subject (n = 1. Motion capture and pressure measurements were used to investigate the effect of the PhAFO on lower limb joint behavior and the capacity of the bellow pump to repeatedly generate the required pneumatic pressure for toe clearance. Results Toe clearance during swing was successfully achieved during all trials; average clearance 44 ± 5 mm. Free ankle motion was observed during stance and plantarflexion was blocked during swing. In addition, the bellow component repeatedly generated an average of 169 kPa per step of pressure during ten minutes of walking. Conclusion This study demonstrated that fluid power could be harvested with a pneumatic circuit built into an AFO, and used to operate an actuated cam-lock mechanism that controls ankle-foot motion at specific periods of the gait cycle.

  2. Ultrasound Findings of the Painful Ankle and Foot

    Directory of Open Access Journals (Sweden)

    Suheil Artul

    2014-01-01

    Full Text Available Objectives: To document the prevalence and spectrum of musculoskeletal ultrasound (MSKUS findings at different parts of the foot. Materials and Methods: All MSKUS studies conducted on the foot during a 2-year period (2012-2013 at the Department of Radiology were reviewed. Demographic parameters including age, gender, and MSKUS findings were documented. Results: Three hundred and sixty-four studies had been conducted in the 2-year period. Ninety-three MSKUS evaluations were done for the ankle, 30 studies for the heel, and 241 for the rest of the foot. The most common MSKUS finding at the ankle was tenosynovitis, mostly in female patients; at the heel it was Achilles tendonitis, also mostly in female patients; and for the rest of the foot it was fluid collection and presence of foreign body, mainly in male patients. The number of different MSKUS abnormalities that were reported was 9 at the ankle, 9 at the heel, and 21 on the rest of the foot. Conclusions: MSKUS has the potential for revealing a huge spectrum of abnormalities. The most common finding was collection/hematoma and foreign bodies at the foot, tenosynovitis at the ankle, and Achilles tendinitis at the heel.

  3. Effects of ankle foot orthoses on body functions and activities in people with floppy paretic ankle muscles : a systematic review

    NARCIS (Netherlands)

    Wilk, van der Dymphy; Dijkstra, Pieter Ubele; Postema, Klaas; Verkerke, Gijsbertus Jacob; Hijmans, Juha Markus

    2015-01-01

    Background: People with floppy ankle muscles paresis use ankle foot orthoses to improve their walking ability. Ankle foot orthoses also limit ankle range of motion thereby introducing additional problems. Insight in effects of ankle foot orthoses on body functions and activities in people with

  4. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton

    Science.gov (United States)

    Malcolm, Philippe; Galle, Samuel; Derave, Wim; De Clercq, Dirk

    2018-01-01

    The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition. Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions. Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments. PMID:29551959

  5. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton

    Directory of Open Access Journals (Sweden)

    Philippe Malcolm

    2018-03-01

    Full Text Available The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition. Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions. Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments.

  6. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton.

    Science.gov (United States)

    Malcolm, Philippe; Galle, Samuel; Derave, Wim; De Clercq, Dirk

    2018-01-01

    The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition . Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions . Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments.

  7. Effects of Ankle Arthrodesis on Biomechanical Performance of the Entire Foot.

    Directory of Open Access Journals (Sweden)

    Yan Wang

    Full Text Available Ankle arthrodesis is one popular surgical treatment for ankle arthritis, chronic instability, and degenerative deformity. However, complications such as foot pain, joint arthritis, and bone fracture may cause patients to suffer other problems. Understanding the internal biomechanics of the foot is critical for assessing the effectiveness of ankle arthrodesis and provides a baseline for the surgical plan. This study aimed to understand the biomechanical effects of ankle arthrodesis on the entire foot and ankle using finite element analyses. A three-dimensional finite element model of the foot and ankle, involving 28 bones, 103 ligaments, the plantar fascia, major muscle groups, and encapsulated soft tissue, was developed and validated. The biomechanical performances of a normal foot and a foot with ankle arthrodesis were compared at three gait instants, first-peak, mid-stance, and second-peak.Changes in plantar pressure distribution, joint contact pressure and forces, von Mises stress on bone and foot deformation were predicted. Compared with those in the normal foot, the peak plantar pressure was increased and the center of pressure moved anteriorly in the foot with ankle arthrodesis. The talonavicular joint and joints of the first to third rays in the hind- and mid-foot bore the majority of the loading and sustained substantially increased loading after ankle arthrodesis. An average contact pressure of 2.14 MPa was predicted at the talonavicular joint after surgery and the maximum variation was shown to be 80% in joints of the first ray. The contact force and pressure of the subtalar joint decreased after surgery, indicating that arthritis at this joint was not necessarily a consequence of ankle arthrodesis but rather a progression of pre-existing degenerative changes. Von Mises stress in the second and third metatarsal bones at the second-peak instant increased to 52 MPa and 34 MPa, respectively, after surgery. These variations can provide

  8. PROSPECTIVE EPIDEMIOLOGICAL STUDY OF BASKETBALL INJURIES DURING ONE COMPETITIVE SEASON: ANKLE SPRAINS AND OVERUSE KNEE INJURIES

    Directory of Open Access Journals (Sweden)

    Elke Cumps

    2007-06-01

    Full Text Available This prospective cohort study aims to assess the overall incidence of acute and overuse basketball injuries and identifies risk factors associated with ankle sprains and knee overuse injuries. In total, 164 senior players (23.7 years ± 7.0 of all levels of play, and including both men and women, participated voluntarily during one season. A total of 139 acute and 87 overuse injuries were reported, resulting in an overall injury incidence of 9.8 (8.5 to 11.1 per 1,000 hours. The incidence of acute injuries was 6.0/1,000 hours. Ankle sprains (n = 34 accounted for most acute injuries, and 52.9% of all players with ankle sprains reported a previous ankle sprain. Relative Risks (RR and Odds Ratio (OR with their 95% Confidence Intervals (CI were calculated to determine significant differences. Landing on an opponent's foot was the major inciting event, significantly more so than non contact mechanisms (RR=2.1 [95% CI: 1.0-4.2]. Acute knee injuries resulted in the highest playing absence (7 weeks 2 days ± 9 weeks 1 day. Overuse injury incidence was 3.8/1,000 hours. The knee (1.5/1,000 hours was the most common site. Forward players sustained less knee overuse injuries than players of all other playing positions, and significantly less than center players (OR=0.5 [95% CI: 0.2-0.9]. This study showed that ankle sprains and overuse knee injuries are the most common injuries in basketball, both accounting for 14.8%. Injury prevention programmes however should not concentrate on those injuries only, but might one to consider that acute knee injuries, in spite of the fact that they occur less frequently, also merit further research.

  9. Postoperative infection in the foot and ankle.

    LENUS (Irish Health Repository)

    Chan, Victoria O

    2012-07-01

    Our discussion highlights the commonly performed surgical procedures in the foot and ankle and reviews the various imaging modalities available for the detection of infection with graphic examples to better enable radiologists to approach the radiological evaluation of postoperative infection in the foot and ankle. Discrimination between infectious and noninfectious inflammation remains a diagnostic challenge usually needing a combination of clinical assessment, laboratory investigations, and imaging studies to increase diagnostic accuracy.

  10. The Effects of Varying Ankle Foot Orthosis Stiffness on Gait in Children with Spastic Cerebral Palsy Who Walk with Excessive Knee Flexion.

    Directory of Open Access Journals (Sweden)

    Yvette L Kerkum

    Full Text Available Rigid Ankle-Foot Orthoses (AFOs are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP. While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A spring-like AFO may enhance push-off power, which may come at the cost of reducing the knee flexion less effectively. Optimizing this trade-off between enhancing push-off power and normalizing knee flexion in stance is expected to maximize gait efficiency. This study investigated the effects of varying AFO stiffness on gait biomechanics and efficiency in children with CP who walk with excessive knee flexion in stance. Fifteen children with spastic CP (11 boys, 10±2 years were prescribed with a ventral shell spring-hinged AFO (vAFO. The hinge was set into a rigid, or spring-like setting, using both a stiff and flexible performance. At baseline (i.e. shoes-only and for each vAFO, a 3D-gait analysis and 6-minute walk test with breath-gas analysis were performed at comfortable speed. Lower limb joint kinematics and kinetics were calculated. From the 6-minute walk test, walking speed and the net energy cost were determined. A generalized estimation equation (p<0.05 was used to analyze the effects of different conditions. Compared to shoes-only, all vAFOs improved the knee angle and net moment similarly. Ankle power generation and work were preserved only by the spring-like vAFOs. All vAFOs decreased the net energy cost compared to shoes-only, but no differences were found between vAFOs, showing that the effects of spring-like vAFOs to promote push-off power did not lead to greater reductions in walking energy cost. These findings suggest that, in this specific group of children with spastic CP, the vAFO stiffness that maximizes gait efficiency is primarily determined by its effect on knee kinematics and kinetics rather than by its effect on push-off power

  11. A Patient-Specific Foot Model for the Estimate of Ankle Joint Forces in Patients with Juvenile Idiopathic Arthritis.

    Science.gov (United States)

    Prinold, Joe A I; Mazzà, Claudia; Di Marco, Roberto; Hannah, Iain; Malattia, Clara; Magni-Manzoni, Silvia; Petrarca, Maurizio; Ronchetti, Anna B; Tanturri de Horatio, Laura; van Dijkhuizen, E H Pieter; Wesarg, Stefan; Viceconti, Marco

    2016-01-01

    Juvenile idiopathic arthritis (JIA) is the leading cause of childhood disability from a musculoskeletal disorder. It generally affects large joints such as the knee and the ankle, often causing structural damage. Different factors contribute to the damage onset, including altered joint loading and other mechanical factors, associated with pain and inflammation. The prediction of patients' joint loading can hence be a valuable tool in understanding the disease mechanisms involved in structural damage progression. A number of lower-limb musculoskeletal models have been proposed to analyse the hip and knee joints, but juvenile models of the foot are still lacking. This paper presents a modelling pipeline that allows the creation of juvenile patient-specific models starting from lower limb kinematics and foot and ankle MRI data. This pipeline has been applied to data from three children with JIA and the importance of patient-specific parameters and modelling assumptions has been tested in a sensitivity analysis focused on the variation of the joint reaction forces. This analysis highlighted the criticality of patient-specific definition of the ankle joint axes and location of the Achilles tendon insertions. Patient-specific detection of the Tibialis Anterior, Tibialis Posterior, and Peroneus Longus origins and insertions were also shown to be important.

  12. Ankle and foot tuberculosis: A diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Biswaranjan Nayak

    2014-01-01

    Full Text Available Aim and Objective: To know the biological behavior of ankle and foot tuberculosis (AFTB and to know the reasons for delay in diagnosis and treatment of AFTB in our population. Materials and Methods: Patients with non-healing ulcers/sinuses/swellings in the ankle and foot region are the subjects of present study. Detailed clinical history, physical examination and relevant investigations were done in all cases. Pus/wound discharge for acid fast bacillus (AFB study and biopsy from wound margin/sinus tract was taken in all the cases. Results: During the period from July 2007-June 2012, 20 cases of AFTB were treated. Out of them five cases were difficult to diagnose and a mean period of 6 month to 5year was elapsed before final diagnosis was established. Out of these five cases - three cases were diabetic with ulcers and sinuses in the heel and ankle region. One case was wrongly diagnosed as angiodysplasia with A-V malformation of foot and diagnosis was delayed for 5 year. In one case of rheumatoid arthritis with abscess in ankle joint, the diagnosis was delayed for 1year. Conclusion: AFTB is very rare condition. AFTB is suspected in cases with long standing pain/swelling/discharging sinus in the foot and thorough investigations is must to differentiate from other foot diseases. Diagnosis is delayed due to lack of clinical suspicion and non-confirmatory biopsy reports. Early diagnosis and ATT for 9-18 months is must in all cases of AFTB to prevent joint involvement and other complications.

  13. Find an Orthopaedic Foot and Ankle MD/DO

    Science.gov (United States)

    ... All Site Content AOFAS / FootCareMD / Find a Surgeon Find a Foot & Ankle Orthopaedic Surgeon Page Content Who ... your prescribed treatment (surgical and/or non-surgical) ​ Find a Surgeon ​ Click here to find a foot ...

  14. Effects of knee and ankle muscle fatigue on postural control in the unipedal stance.

    Science.gov (United States)

    Bizid, Riadh; Margnes, Eric; François, Yrieix; Jully, Jean Louis; Gonzalez, Gerard; Dupui, Philippe; Paillard, Thierry

    2009-06-01

    The aim of this study was to compare the effects of acute muscle fatigue of the ankle and knee musculature on postural control by immediate measures after performing fatiguing tasks (POST condition). One group of subjects (n = 8) performed a fatiguing task by voluntary contractions of the triceps surae (group TRI) and the other (n = 9) performed a fatiguing task by voluntary contractions of the quadriceps femoris (group QUA). Each muscle group was exercised until the loss of maximal voluntary contraction torque reached 50% (isokinetic dynamometer). Posture was assessed by measuring the centre of foot pressure (COP) with a force platform during a test of unipedal quiet standing posture with eyes closed. Initially (in PRE condition), the mean COP velocity was not significantly different between group TRI and group QUA. In POST condition, the mean COP velocity increased more in group QUA than in group TRI. The postural control was more impaired by knee muscle fatigue than by ankle muscle fatigue.

  15. Influence of increasing knee flexion angle on knee-ankle varus stress during single-leg jump landing

    Directory of Open Access Journals (Sweden)

    Mariam A. Ameer, PhD

    2017-12-01

    Full Text Available Objectives: The primary aim of this study was to identify the relationship between the peak knee flexion angle and knee-ankle varus stress in the landing phase of the single-leg jump during running. Methods: Fifteen male handball players from the first Saudi Arabian handball team were incorporated in this study. Each player performed a single-leg jump-land after running a fixed distance of 450 cm. The data were measured using a 3D motion analysis system. The maximum knee flexion angle, knee varus angle, centre of pressure pathway in the medio-lateral direction, and ankle varus moment were measured. Results: The Pearson Product Moment Correlation showed that a greater knee flexion angle was related to a greater lateral displacement of the centre of pressure (r = 0.794, P = 0.000, a greater ankle varus moment (r = 0.707, P = 0.003, and a greater knee varus angle (r = 0.753, P = 0.001. In addition, the greater ankle varus moment was related to the greater lateral displacement of the centre of pressure (r = 0.734, P = 0.002. Conclusions: These findings may help physical therapists and conditioning professionals to understand the impact of increasing knee flexion angle on the lower limb joints. Such findings may help to develop training protocols for enhancing the lateral body reaction during the landing phase of the single-leg jump, which may protect the knee and ankle joints from excessive varus stresses. Keywords: 3D motion analysis, Ankle kinetic, Centre of pressure pathway, Handball playing, Knee kinematic, Single-leg jump

  16. Knee and Ankle Arthroplasty in Hemophilia

    Directory of Open Access Journals (Sweden)

    Luigi Piero Solimeno

    2017-11-01

    Full Text Available Today, major surgical procedures can be safely performed in hemophilic patients with chronic arthropathy, using available factor concentrates. In this setting, total knee replacement is considered the “gold standard”, while the use of total ankle replacement is still debated. Indeed, the unsatisfactory results obtained with the previous available design of implants did not raise enthusiasm as knee or hip replacement. Recently, the introduction of new implant designs and better reported outcomes have renewed the interest in total ankle replacement in people with hemophilia. In this review, the role of replacement surgery in the treatment of chronic hemophilic arthropathy will be described.

  17. Diabetic charcot neuroarthropathy of the foot and ankle with osteomyelitis.

    Science.gov (United States)

    Ramanujam, Crystal L; Stapleton, John J; Zgonis, Thomas

    2014-10-01

    One of the most devastating foot and/or ankle complications in the diabetic population with peripheral neuropathy is the presence of Charcot neuroarthropathy (CN). In recent years, diabetic limb salvage has been attempted more frequently as opposed to major lower extremity amputation for CN of the foot and ankle with ulceration and/or deep infection. Treatment strategies for osteomyelitis in the diabetic population have evolved. This article reviews some of the most common surgical strategies recommended for the diabetic patient with CN of the foot and/or ankle and concomitant osteomyelitis. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Welcome to Journal of Foot and Ankle Research: a new open access journal for foot health professionals

    Directory of Open Access Journals (Sweden)

    Borthwick Alan M

    2008-07-01

    Full Text Available Abstract Journal of Foot and Ankle Research (JFAR is a new, open access, peer-reviewed online journal that encompasses all aspects of policy, organisation, delivery and clinical practice related to the assessment, diagnosis, prevention and management of foot and ankle disorders. JFAR will cover a wide range of clinical subject areas, including diabetology, paediatrics, sports medicine, gerontology and geriatrics, foot surgery, physical therapy, dermatology, wound management, radiology, biomechanics and bioengineering, orthotics and prosthetics, as well the broad areas of epidemiology, policy, organisation and delivery of services related to foot and ankle care. The journal encourages submission from all health professionals who manage lower limb conditions, including podiatrists, nurses, physical therapists and physiotherapists, orthopaedists, manual therapists, medical specialists and general medical practitioners, as well as health service researchers concerned with foot and ankle care. All manuscripts will undergo open peer review, and all accepted manuscripts will be freely available on-line using the open access platform of BioMed Central.

  19. Minimally invasive soft tissue release of foot and ankle contracture secondary to stroke.

    Science.gov (United States)

    Boffeli, Troy J; Collier, Rachel C

    2014-01-01

    Lower extremity contracture associated with stroke commonly results in a nonreducible, spastic equinovarus deformity of the foot and ankle. Rigid contracture deformity leads to gait instability, pain, bracing difficulties, and ulcerations. The classic surgical approach for stroke-related contracture of the foot and ankle has been combinations of tendon lengthening, tendon transfer, osteotomy, and joint fusion procedures. Recovery after traditional foot and ankle reconstructive surgery requires a period of non-weightbearing that is not typically practical for these patients. Little focus has been given in published studies on minimally invasive soft tissue release of contracture. We present the case of a 61-year-old female with an equinovarus foot contracture deformity secondary to stroke. The patient underwent Achilles tendon lengthening, posterior tibial tendon Z lengthening, and digital flexor tenotomy of each toe with immediate weightbearing in a walking boot, followed by transition to an ankle-foot orthosis. The surgical principles and technique tips are presented to demonstrate our minimally invasive approach to release of foot and ankle contracture secondary to stroke. The main goal of this approach is to improve foot and ankle alignment for ease of bracing, which, in turn, will improve gait, reduce the risk of falls, decrease pain, and avoid the development of pressure sores. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Immediate effect of a single anteroposterior talus mobilization on dorsiflexion range of motion in participants with orthopedic dysfunction of the ankle and foot.

    Science.gov (United States)

    Teixeira, Luciana Mundim; Pires, Tatiana; Silva, Rafael Duarte; de Resende, Marcos Antônio

    2013-01-01

    The purpose of this study was to determine the immediate effects of a single anteroposterior mobilization of the talus on the active dorsiflexion range of motion (ROM) in participants with different orthopedic foot and ankle injuries. This study included 30 male and female participants aged 18 to 50 years with unilateral orthopedic foot and ankle dysfunction. All participants underwent 3 sets of active dorsiflexion ROM measurement in both ankles. Measurements included baseline, post-first treatment, and post-second treatment values. Participants received either joint mobilization or manual contact (control) on the affected ankle. Active dorsiflexion ROM was assessed using a biplanar goniometer with participants in the prone position and 90° of knee flexion. Both groups (joint mobilization and manual contact) showed increased active dorsiflexion ROM. However, the mean difference of dorsiflexion measurements before and after mobilization was greater than before and after control treatment. A single session of articular mobilization of the talus did not significantly increase dorsiflexion ROM in participants with orthopedic dysfunctions of the ankle and foot compared with a manual contact procedure. Copyright © 2013 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  1. Validation of Patient-Reported Outcomes Measurement Information System Computerized Adaptive Tests Against the Foot and Ankle Outcome Score for 6 Common Foot and Ankle Pathologies.

    Science.gov (United States)

    Koltsov, Jayme C B; Greenfield, Stephen T; Soukup, Dylan; Do, Huong T; Ellis, Scott J

    2017-08-01

    The field of foot and ankle surgery lacks a widely accepted gold-standard patient-reported outcome instrument. With the changing infrastructure of the medical profession, more efficient patient-reported outcome tools are needed to reduce respondent burden and increase participation while providing consistent and reliable measurement across multiple pathologies and disciplines. The primary purpose of the present study was to validate 3 Patient-Reported Outcomes Measurement Information System computer adaptive tests (CATs) most relevant to the foot and ankle discipline against the Foot and Ankle Outcome Score (FAOS) and the Short Form 12 general health status survey in patients with 6 common foot and ankle pathologies. Patients (n = 240) indicated for operative treatment for 1 of 6 common foot and ankle pathologies completed the CATs, FAOS, and Short Form 12 at their preoperative surgical visits, 1 week subsequently (before surgery), and at 6 months postoperatively. The psychometric properties of the instruments were assessed and compared. The Patient-Reported Outcomes Measurement Information System CATs each took less than 1 minute to complete, whereas the FAOS took 6.5 minutes, and the Short Form 12 took 3 minutes. CAT scores were more normally distributed and had fewer floor and ceiling effects than those on the FAOS, which reached as high as 24%. The CATs were more precise than the FAOS and had similar responsiveness and test-retest reliability. The physical function and mobility CATs correlated strongly with the activities subscale of the FAOS, and the pain interference CAT correlated strongly with the pain subscale of the FAOS. The CATs and FAOS were responsive to changes with operative treatment for 6 common foot and ankle pathologies. The CATs performed as well as or better than the FAOS in all aspects of psychometric validity. The Patient-Reported Outcomes Measurement Information System CATs show tremendous potential for improving the study of patient

  2. Incidence and variance of foot and ankle injuries in elite college football players.

    Science.gov (United States)

    Kaplan, Lee D; Jost, Patrick W; Honkamp, Nicholas; Norwig, John; West, Robin; Bradley, James P

    2011-01-01

    We conducted a study on the risk for foot and ankle injuries in college football players on the basis of injury type and player position. In February 2006, we evaluated 320 intercollegiate football players at the National Football League Combine. All pathologic conditions and surgical procedures of the foot and ankle were recorded, and data were analyzed by player position to detect any trends. Seventy-two percent (n = 231) of the players had a history of foot and ankle injuries, with a total of 287 foot and ankle injuries (1.24 injuries/player injured). The most common injuries were lateral ankle sprain (n = 115), syndesmotic sprain (50), metatarsophalangeal dislocation/turf toe (36), and fibular fracture (25). Foot and ankle injuries were most common in kickers/punters (100% incidence), special teams (100%), running backs (83%), wide receivers (83%), and offensive linemen (80%). Lateral ankle sprains, the most common injuries, were treated surgically only 2.6% of the time. Offensive linemen were most likely to have had syndesmotic sprains (32%), and quarterbacks had the highest incidence of fibular fractures (16%). Foot and ankle injuries are common in collegiate football players, affecting 72% of players. Thirteen percent underwent surgical treatment. Trends are seen in the types of injuries for the different player positions.

  3. Visualisation to enhance biomechanical tuning of ankle-foot orthoses (AFOs in stroke: study protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Carse Bruce

    2011-12-01

    Full Text Available Abstract Background There are a number of gaps in the evidence base for the use of ankle-foot orthoses for stroke patients. Three dimensional motion analysis offers an ideal method for objectively obtaining biomechanical gait data from stroke patients, however there are a number of major barriers to its use in routine clinical practice. One significant problem is the way in which the biomechanical data generated by these systems is presented. Through the careful design of bespoke biomechanical visualisation software it may be possible to present such data in novel ways to improve clinical decision making, track progress and increase patient understanding in the context of ankle-foot orthosis tuning. Methods A single-blind randomised controlled trial will be used to compare the use of biomechanical visualisation software in ankle-foot orthosis tuning against standard care (tuning using observation alone. Participants (n = 70 will have experienced a recent hemiplegia (1-12 months and will be identified by their care team as being suitable candidates for a rigid ankle-foot orthosis. The primary outcome measure will be walking velocity. Secondary outcome measures include; lower limb joint kinematics (thigh and shank global orientations & kinetics (knee and hip flexion/extension moments, ground reaction force FZ2 peak magnitude, step length, symmetry ratio based on step length, Modified Ashworth Scale, Modified Rivermead Mobility Index and EuroQol (EQ-5D. Additional qualitative measures will also be taken from participants (patients and clinicians at the beginning and end of their participation in the study. The main aim of the study is to determine whether or not the visualisation of biomechanical data can be used to improve the outcomes of tuning ankle-foot orthoses for stroke patients. Discussion In addition to answering the primary research question the broad range of measures that will be taken during this study are likely to contribute to a

  4. The effect of prosthetic foot push-off on mechanical loading associated with knee osteoarthritis in lower extremity amputees.

    Science.gov (United States)

    Morgenroth, David C; Segal, Ava D; Zelik, Karl E; Czerniecki, Joseph M; Klute, Glenn K; Adamczyk, Peter G; Orendurff, Michael S; Hahn, Michael E; Collins, Steven H; Kuo, Art D

    2011-10-01

    Lower extremity amputation not only limits mobility, but also increases the risk of knee osteoarthritis of the intact limb. Dynamic walking models of non-amputees suggest that pushing-off from the trailing limb can reduce collision forces on the leading limb. These collision forces may determine the peak knee external adduction moment (EAM), which has been linked to the development of knee OA in the general population. We therefore hypothesized that greater prosthetic push-off would lead to reduced loading and knee EAM of the intact limb in unilateral transtibial amputees. Seven unilateral transtibial amputees were studied during gait under three prosthetic foot conditions that were intended to vary push-off. Prosthetic foot-ankle push-off work, intact limb knee EAM and ground reaction impulses for both limbs during step-to-step transition were measured. Overall, trailing limb prosthetic push-off work was negatively correlated with leading intact limb 1st peak knee EAM (slope=-.72±.22; p=.011). Prosthetic push-off work and 1st peak intact knee EAM varied significantly with foot type. The prosthetic foot condition with the least push-off demonstrated the largest knee EAM, which was reduced by 26% with the prosthetic foot producing the most push-off. Trailing prosthetic limb push-off impulse was negatively correlated with leading intact limb loading impulse (slope=-.34±.14; p=.001), which may help explain how prosthetic limb push-off can affect intact limb loading. Prosthetic feet that perform more prosthetic push-off appear to be associated with a reduction in 1st peak intact knee EAM, and their use could potentially reduce the risk and burden of knee osteoarthritis in this population. Published by Elsevier B.V.

  5. Gait kinematics of subjects with ankle instability using a multisegmented foot model.

    Science.gov (United States)

    De Ridder, Roel; Willems, Tine; Vanrenterghem, Jos; Robinson, Mark; Pataky, Todd; Roosen, Philip

    2013-11-01

    Many patients who sustain an acute lateral ankle sprain develop chronic ankle instability (CAI). Altered ankle kinematics have been reported to play a role in the underlying mechanisms of CAI. In previous studies, however, the foot was modeled as one rigid segment, ignoring the complexity of the ankle and foot anatomy and kinematics. The purpose of this study was to evaluate stance phase kinematics of subjects with CAI, copers, and controls during walking and running using both a rigid and a multisegmented foot model. Foot and ankle kinematics of 77 subjects (29 subjects with self-reported CAI, 24 copers, and 24 controls) were measured during barefoot walking and running using a rigid foot model and a six-segment Ghent Foot Model. Data were collected on a 20-m-long instrumented runway embedded with a force plate and a six-camera optoelectronic system. Groups were compared using statistical parametric mapping. Both the CAI and the coper group showed similar differences during midstance and late stance compared with the control group (P foot segment showed a more everted position during walking compared with the control group. Based on the Ghent Foot Model, the rear foot also showed a more everted position during running. The medial forefoot showed a more inverted position for both running and walking compared with the control group. Our study revealed significant midstance and late stance differences in rigid foot, rear foot, and medial forefoot kinematics The multisegmented foot model demonstrated intricate behavior of the foot that is not detectable with rigid foot modeling. Further research using these models is necessary to expand knowledge of foot kinematics in subjects with CAI.

  6. Reliability, validity and responsiveness of the German self-reported foot and ankle score (SEFAS) in patients with foot or ankle surgery.

    Science.gov (United States)

    Arbab, Dariusch; Kuhlmann, Katharina; Schnurr, Christoph; Bouillon, Bertil; Lüring, Christian; König, Dietmar

    2017-10-10

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures and are increasingly used in clinical trials to assess outcomes of health care. The intention of this study was to develop and culturally adapt a German version of the Self-reported Foot and Ankle Score (SEFAS) and to evaluate reliability, validity and responsiveness. According to Cross Cultural Adaptation of Self-Reported Measure guidelines forward and backward translation has been performed. The German SEFAS was investigated in 177 consecutive patients. 177 Patients completed the German SEFAS, Foot and Ankle Outcome Score (FAOS), Short-Form 36 and numeric scales for pain and disability (NRS) before and 118 patients 6 months after foot or ankle surgery. Test-Retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German SEFAS demonstrated excellent test-retest reliability with ICC values of 0.97. Cronbach's alpha (α) value of 0.89 demonstrated strong internal consistency. No floor or ceiling effects were observed for the German version of the SEFAS. As hypothesized SEFAS correlated strongly with FAOS and SF-36 domains. It showed moderate (ES/SRM > 0.5) responsiveness between preoperative assessment and postoperative follow-up. The German version of the SEFAS demonstrated good psychometric properties. It proofed to be a valid and reliable instrument for use in foot and ankle patients. DRKS00007585.

  7. A functional comparison of conventional knee-ankle-foot orthoses and a microprocessor-controlled leg orthosis system based on biomechanical parameters.

    Science.gov (United States)

    Schmalz, Thomas; Pröbsting, Eva; Auberger, Roland; Siewert, Gordon

    2016-04-01

    The microprocessor-controlled leg orthosis C-Brace enables patients with paretic or paralysed lower limb muscles to use dampened knee flexion under weight-bearing and speed-adapted control of the swing phase. The objective of the present study was to investigate the new technical functions of the C-Brace orthosis, based on biomechanical parameters. The study enrolled six patients. The C-Brace orthosis is compared with conventional leg orthoses (four stance control orthoses, two locked knee-ankle-foot orthoses) using biomechanical parameters of level walking, descending ramps and descending stairs. Ground reaction forces, joint moments and kinematic parameters were measured for level walking as well as ascending and descending ramps and stairs. With the C-Brace, a nearly natural stance phase knee flexion was measured during level walking (mean value 11° ± 5.6°). The maximum swing phase knee flexion angle of the C-Brace approached the normal value of 65° more closely than the stance control orthoses (66° ± 8.5° vs 74° ± 6.4°). No significant differences in the joint moments were found between the C-Brace and stance control orthosis conditions. In contrast to the conventional orthoses, all patients were able to ambulate ramps and stairs using a step-over-step technique with C-Brace (flexion angle 64.6° ± 8.2° and 70.5° ± 12.4°). The results show that the functions of the C-Brace for situation-dependent knee flexion under weight bearing have been used by patients with a high level of confidence. The functional benefits of the C-Brace in comparison with the conventional orthotic mechanisms could be demonstrated most clearly for descending ramps and stairs. The C-Brace orthosis is able to combine improved orthotic function with sustained orthotic safety. © The International Society for Prosthetics and Orthotics 2014.

  8. Acute Ankle Sprain in a Mouse Model: Changes in Knee-Joint Space.

    Science.gov (United States)

    Hubbard-Turner, Tricia; Wikstrom, Erik A; Guderian, Sophie; Turner, Michael J

    2017-06-02

    Ankle sprains remain the most common orthopaedic injury. Conducting long-term studies in humans is difficult and costly, so the long-term consequences of an ankle sprain are not entirely known.   To measure knee-joint space after a single surgically induced ankle sprain in mice.   Randomized controlled trial.   University research laboratory.   Thirty male mice (CBA/2J) were randomly placed into 1 of 3 surgical groups: the transected calcaneofibular ligament (CFL) group, the transected anterior talofibular ligament/CFL group, or a sham treatment group. The right ankle was operated on in all mice.   Three days after surgery, all of the mice were individually housed in cages containing a solid-surface running wheel, and daily running-wheel measurements were recorded. Before surgery and every 6 weeks after surgery, a diagnostic ultrasound was used to measure medial and lateral knee-joint space in both hind limbs.   Right medial (P = .003), right lateral (P = .002), left medial (P = .03), and left lateral (P = .002) knee-joint spaces decreased across the life span. The mice in the anterior talofibular ligament/CFL group had decreased right medial (P = .004) joint space compared with the sham and CFL groups starting at 24 weeks of age and continuing throughout the life span. No differences occurred in contralateral knee-joint degeneration among any of the groups.   Based on current data, mice that sustained a surgically induced severe ankle sprain developed greater joint degeneration in the ipsilateral knee. Knee degeneration could result from accommodation to the laxity of the ankle or biomechanical alterations secondary to ankle instability. A single surgically induced ankle sprain could significantly affect knee-joint function.

  9. Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position.

    Science.gov (United States)

    Cho, Kang Hee; Jeon, Yumi; Lee, Hyunkeun

    2016-04-01

    To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint.

  10. Dedicated extremity MR imaging of the foot and ankle

    International Nuclear Information System (INIS)

    Hottya, G.A.; Peterfy, C.G.; Uffmann, M.; Haeckl, F.O.; LeHir, P.; Redei, J.; Gindele, A.U.; Dion, E.; Genant, H.K.

    2000-01-01

    The purpose of this review is to provide illustrative examples of diseases of the foot and ankle when imaged with a low-field MR imaging system. A retrospective review of 268 foot and ankle examinations, performed in our institution within the past 3 years with a 0.2-T (Artoscan Esaote, Genoa, Italy) dedicated extremity MR system was done. Additionally, illustrative comparison with conventional radiography and high-field MR imaging is presented in patients in whom these examinations were also performed. Although motion artifact limited the value of a few studies, in the majority of examinations low-field MR imaging provided diagnostic image quality for the full spectrum of disorders affecting the foot and ankle and seemed to be a feasible alternative to high-field MR imaging in establishing an accurate diagnosis. (orig.)

  11. The Effects of Varying Ankle Foot Orthosis Stiffness on Gait in Children with Spastic Cerebral Palsy Who Walk with Excessive Knee Flexion.

    Science.gov (United States)

    Kerkum, Yvette L; Buizer, Annemieke I; van den Noort, Josien C; Becher, Jules G; Harlaar, Jaap; Brehm, Merel-Anne

    2015-01-01

    Rigid Ankle-Foot Orthoses (AFOs) are commonly prescribed to counteract excessive knee flexion during the stance phase of gait in children with cerebral palsy (CP). While rigid AFOs may normalize knee kinematics and kinetics effectively, it has the disadvantage of impeding push-off power. A spring-like AFO may enhance push-off power, which may come at the cost of reducing the knee flexion less effectively. Optimizing this trade-off between enhancing push-off power and normalizing knee flexion in stance is expected to maximize gait efficiency. This study investigated the effects of varying AFO stiffness on gait biomechanics and efficiency in children with CP who walk with excessive knee flexion in stance. Fifteen children with spastic CP (11 boys, 10±2 years) were prescribed with a ventral shell spring-hinged AFO (vAFO). The hinge was set into a rigid, or spring-like setting, using both a stiff and flexible performance. At baseline (i.e. shoes-only) and for each vAFO, a 3D-gait analysis and 6-minute walk test with breath-gas analysis were performed at comfortable speed. Lower limb joint kinematics and kinetics were calculated. From the 6-minute walk test, walking speed and the net energy cost were determined. A generalized estimation equation (ppush-off power did not lead to greater reductions in walking energy cost. These findings suggest that, in this specific group of children with spastic CP, the vAFO stiffness that maximizes gait efficiency is primarily determined by its effect on knee kinematics and kinetics rather than by its effect on push-off power. Dutch Trial Register NTR3418.

  12. Fleet of Foot: Adolescent Foot and Ankle Mobility

    Science.gov (United States)

    Legacy, Kelly Bromley

    2018-01-01

    In today's world of advanced technologies, accessible transportation, and fingertip talking, adolescents are spending too many hours each day sedentary. The purpose of this article is to underscore the importance of foot and ankle mobility in an adolescent population that spends very little time on their feet. Physical educators and athletic…

  13. Optimization of prosthetic foot stiffness to reduce metabolic cost and intact knee loading during below-knee amputee walking: a theoretical study.

    Science.gov (United States)

    Fey, Nicholas P; Klute, Glenn K; Neptune, Richard R

    2012-11-01

    Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. However, the prescription of appropriate design characteristics (e.g., stiffness) is not well-defined since its influence on foot function and important in vivo biomechanical quantities such as metabolic cost and joint loading remain unclear. The design of feet that improve these quantities could provide considerable advancements in amputee care. Therefore, the purpose of this study was to couple design optimization with dynamic simulations of amputee walking to identify the optimal foot stiffness that minimizes metabolic cost and intact knee joint loading. A musculoskeletal model and distributed stiffness ESAR prosthetic foot model were developed to generate muscle-actuated forward dynamics simulations of amputee walking. Dynamic optimization was used to solve for the optimal muscle excitation patterns and foot stiffness profile that produced simulations that tracked experimental amputee walking data while minimizing metabolic cost and intact leg internal knee contact forces. Muscle and foot function were evaluated by calculating their contributions to the important walking subtasks of body support, forward propulsion and leg swing. The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also

  14. Comparison of Multisegmental Foot and Ankle Motion Between Total Ankle Replacement and Ankle Arthrodesis in Adults.

    Science.gov (United States)

    Seo, Sang Gyo; Kim, Eo Jin; Lee, Doo Jae; Bae, Kee Jeong; Lee, Kyoung Min; Lee, Dong Yeon

    2017-09-01

    Total ankle replacement (TAR) and ankle arthrodesis (AA) are usually performed for severe ankle arthritis. We compared postoperative foot segmental motion during gait in patients treated with TAR and AA. Gait analysis was performed in 17 and 7 patients undergoing TAR and AA, respectively. Subjects were evaluated using a 3-dimensional multisegmental foot model with 15 markers. Temporal gait parameters were calculated. The maximum and minimum values and the differences in hallux, forefoot, hindfoot, and arch in 3 planes (sagittal, coronal, transverse) were compared between the 2 groups. One hundred healthy adults were evaluated as a control. Gait speed was faster in the TAR ( P = .028). On analysis of foot and ankle segmental motion, the range of hindfoot sagittal motion was significantly greater in the TAR (15.1 vs 10.2 degrees in AA; P = .004). The main component of motion increase was hindfoot dorsiflexion (12.3 and 8.6 degrees). The range of forefoot sagittal motion was greater in the TAR (9.3 vs 5.8 degrees in AA; P = .004). Maximum ankle power in the TAR (1.16) was significantly higher than 0.32 in AA; P = .008). However, the range of hindfoot and forefoot sagittal motion was decreased in both TAR and AA compared with the control group ( P = .000). Although biomechanical results of TAR and AA were not similar to those in the normal controls, joint motions in the TAR more closely matched normal values. Treatment decision making should involve considerations of the effect of surgery on the adjacent joints. Level III, case-control study.

  15. The effect of ankle foot orthosis stiffness on the energy cost of walking: a simulation study.

    Science.gov (United States)

    Bregman, D J J; van der Krogt, M M; de Groot, V; Harlaar, J; Wisse, M; Collins, S H

    2011-11-01

    In stroke and multiple sclerosis patients, gait is frequently hampered by a reduced ability to push-off with the ankle caused by weakness of the plantar-flexor muscles. To enhance ankle push-off and to decrease the high energy cost of walking, spring-like carbon-composite Ankle Foot Orthoses are frequently prescribed. However, it is unknown what Ankle Foot Orthoses stiffness should be used to obtain the most efficient gait. The aim of this simulation study was to gain insights into the effect of variation in Ankle Foot Orthosis stiffness on the amount of energy stored in the Ankle Foot Orthosis and the energy cost of walking. We developed a two-dimensional forward-dynamic walking model with a passive spring at the ankle representing the Ankle Foot Orthosis and two constant torques at the hip for propulsion. We varied Ankle Foot Orthosis stiffness while keeping speed and step length constant. We found an optimal stiffness, at which the energy delivered at the hip joint was minimal. Energy cost decreased with increasing energy storage in the ankle foot orthosis, but the most efficient gait did not occur with maximal energy storage. With maximum storage, push-off occurred too late to reduce the impact of the contralateral leg with the floor. Maximum return prior to foot strike was also suboptimal, as push-off occurred too early and its effects were subsequently counteracted by gravity. The optimal Ankle Foot Orthosis stiffness resulted in significant push-off timed just prior to foot strike and led to greater ankle plantar-flexion velocity just before contralateral foot strike. Our results suggest that patient energy cost might be reduced by the proper choice of Ankle Foot Orthosis stiffness. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Assessment of acute foot and ankle sprains.

    Science.gov (United States)

    Lynam, Louise

    2006-07-01

    Acute ankle and foot trauma is a regular emergency presentation and prompt strategic assessment skills are required to enable nurses to categorise and prioritise these injuries appropriately. This article provides background information on the anatomy and physiology of the lower limb to help nurses to identify various grades of ankle sprain as well as injuries that are limb threatening

  17. MRI diagnosis of soft ganglion cyst in the foot and ankle

    International Nuclear Information System (INIS)

    Zhang Zhaohui; Liang Manqiu; Li Zhuhao

    2011-01-01

    Objective: To explore the clinical and MR imaging features of soft tissue ganglion cyst in the foot and ankle. Methods: Clinical and MR imaging data of 12 patients (male to female ratio 1:5, mean age 47 years) with soft tissue ganglion cysts in the feet and ankles were retrospectively analyzed. Results: The 12 ganglion cysts were located near the first metatarsophalangeal joint (2), in the medial dorsum of foot (4), in the ankle (5) and in the heel (1). Compared with muscle, all lesions showed homogeneous slight T 1 hypointensity and T 2 hyperintensity with thin mural enhancement following the injection of Gd-DTPA. Ten cases were multilocular, and 5 showed mild pericystic edema. Conclusion: Soft tissue ganglion cyst of the foot and ankle are more common in middle aged women. They are frequently located in the ankle and medial dorsum of foot. On MRI they usually appear as multilocular cysts with homogeneous slightly low signal intensity relative to muscle on T 1 WI, high signal intensity on T 2 WI and contrast enhancement of the thin wall. (authors)

  18. Ankle foot orthosis-footwear combination tuning: an investigation into common clinical practice in the United Kingdom.

    Science.gov (United States)

    Eddison, Nicola; Chockalingam, Nachiappan; Osborne, Stephen

    2015-04-01

    Ankle foot orthoses are used to treat a wide variety of gait pathologies. Ankle foot orthosis-footwear combination tuning should be routine clinical practice when prescribing an ankle foot orthosis. Current research suggests that failure to tune ankle foot orthosis-footwear combinations can lead to immediate detrimental effect on function, and in the longer term, it may actually contribute to deterioration. The purpose of this preliminary study was to identify the current level of knowledge clinicians have in the United Kingdom regarding ankle foot orthosis-footwear combination tuning and to investigate common clinical practice regarding ankle foot orthosis-footwear combination tuning among UK orthotists. Cross-sectional survey. A prospective study employing a multi-item questionnaire was sent out to registered orthotists and uploaded on to the official website of British Association of Prosthetists and Orthotists to be accessed by their members. A total of 41 completed questionnaires were received. The results demonstrate that only 50% of participants use ankle foot orthosis-footwear combination tuning as standard clinical practice. The most prevalent factors preventing participants from carrying out ankle foot orthosis-footwear combination tuning are a lack of access to three-dimensional gait analysis equipment (37%) and a lack of time available in their clinics (27%). Although, ankle foot orthosis-footwear combination tuning has been identified as an essential aspect of the prescription of ankle foot orthoses, the results of this study show a lack of understanding of the key principles behind ankle foot orthosis-footwear combination tuning. © The International Society for Prosthetics and Orthotics 2014.

  19. [Dutch-language patient-reported outcome measures for foot and ankle injuries; a systematic review].

    Science.gov (United States)

    Weel, Hanneke; Zwiers, Ruben; Sierevelt, Inger N; Haverkamp, Daniel; van Dijk, C Niek; Kerkhoffs, Gino M M J

    2015-01-01

    To investigate which valid and reliable patient-reported outcome measures (PROMs) are available for foot and ankle disorders in the Dutch population, and which of these is the most suitable for uniform use. Systematic review. PubMed, Embase and Google Scholar were systematically searched for relevant articles; subsequently two researchers screened first the title and the abstract, and then the full article within a selection of these articles. Studies that described a validation process for foot- and ankle-PROMs in a Dutch population were included. Data on measurement characteristics and translation procedure were extracted, and methodological quality of the studies was assessed using the COSMIN checklist. ('COSMIN' stands for 'Consensus-based standards for the selection of health status measurement instruments'.) Two general foot- and ankle-PROMs in the Dutch language were validated: the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measurement (FAAM); two foot-PROMs: the Manchester Foot Pain and Disability Index (MFPDI) and the 5-point Foot Function Index (FFI-5pt) were also validated. There were also two disorder-specific PROMs available in Dutch: the Victorian Institute of Sports Assessment-Achilles (VISA-A) for Achilles tendinopathies and the Foot Impact Scale for Rheumatoid Arthritis (FIS-RA) for rheumatoid arthritis patients. The FAOS and the FFI-5pt showed the strongest evidence for having good measurement characteristics. Currently, we regard the FAOS as the most appropriate foot- and ankle-PROM for general foot and ankle problems. Further studies of higher methodological quality are, however, required to draw firmer conclusions.

  20. Reliability, validity and responsiveness of the Spanish Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery.

    Science.gov (United States)

    Garcés, Juan B Gerstner; Winson, Ian; Goldhahn, Sabine; Castro, Michael D; Swords, Michael P; Grujic, Leslie; Rammelt, Stefan; Sands, Andrew K

    2016-03-01

    The Manchester-Oxford Foot Questionnaire (MOXFQ) has been validated in Spanish for use in patients undergoing foot and ankle surgery. 120 patients completed the MOXFQ and the SF-36 before surgery and 6 and 12 months postoperative. Surgeons completed the American Orthopaedic Foot and Ankle Society (AOFAS) Clinical Rating System. Psychometric properties were assessed for all three MOXFQ dimensions, and for the MOXFQ Index. The Spanish MOXFQ demonstrated consistency with Cronbach's alpha values between 0.65 and 0.90, and reliability ([ICCs] >0.95). It shows a moderate to strong correlation between the Walking/standing dimension and the related domains of the SF-36 (|r|>0.6), the AOFAS Ankle-Hindfoot Scale (|r|>0.47) and Hallux-MTP-IP Scale (|r|>0.64). Responsiveness was excellent, (effect sizes >2.1). The respective minimal detectable change (MDC90) was 14.18 for the MOXFQ Index. The Spanish version of the MOXFQ showed good psychometric properties in patients with foot and ankle disorders. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  1. Examining Ankle-Joint Laxity Using 2 Knee Positions and With Simulated Muscle Guarding.

    Science.gov (United States)

    Hanlon, Shawn; Caccese, Jaclyn; Knight, Christopher A; Swanik, Charles Buz; Kaminski, Thomas W

    2016-02-01

    Several factors affect the reliability of the anterior drawer and talar tilt tests, including the individual clinician's experience and skill, ankle and knee positioning, and muscle guarding. To compare gastrocnemius activity during the measurement of ankle-complex motion at different knee positions, and secondarily, to compare ankle-complex motion during a simulated trial of muscle guarding. Cross-sectional study. Research laboratory. Thirty-three participants aged 20.2 ± 1.7 years were tested. The ankle was loaded under 2 test conditions (relaxed, simulated muscle guarding) at 2 knee positions (0°, 90° of flexion) while gastrocnemius electromyography (EMG) activity was recorded. Anterior displacement (mm), inversion-eversion motion (°), and peak EMG amplitude values of the gastrocnemius (μV). Anterior displacement did not differ between the positions of 0° and 90° of knee flexion (P = .193). Inversion-eversion motion was greater at 0° of knee flexion compared with 90° (P ankle laxity at the 2 most common knee positions for anterior drawer testing; however, talar tilt testing may be best performed with the knee in 0° of knee flexion. Finally, our outcomes from the simulated muscle-guarding condition suggest that clinicians should use caution and be aware of reduced perceived laxity when performing these clinical examination techniques immediately postinjury.

  2. Quality of research and level of evidence in foot and ankle publications.

    Science.gov (United States)

    Barske, Heather L; Baumhauer, Judith

    2012-01-01

    The quality of research and evidence to support medical treatments is under scrutiny from the medical profession and the public. This study examined the current quality of research and level of evidence (LOE) of foot and ankle surgery papers published in orthopedic and podiatric medical journals. Two independent evaluators performed a blinded assessment of all foot and ankle clinical research articles (January 2010 to June 2010) from seven North American orthopedic and podiatric journals. JBJS-A grading system was used for LOE. Articles were assessed for indicators of study quality. The data was stratified by journal and medical credentials. A total of 245 articles were published, 128 were excluded based on study design, leaving 117 clinical research articles. Seven (6%) were Level I, 14 (12%) Level II, 18 (15%) Level III, and 78 (67%) Level IV. The orthopedic journals published 78 studies on foot and ankle topics. Of the podiatric journals, the Journal of the American Podiatric Medical Association (JAPMA) published 12 clinical studies and the Journal of Foot and Ankle Surgery (JFAS) published 27, 21 (78%) of which were Level IV studies. When the quality of research was examined, few therapeutic studies used validated outcome measures and only 38 of 96 (40%) gathered data prospectively. Thirty (31%) studies used a comparison group. Eighty-seven articles (74%) were authored by a MD and 22 (19%) by a DPM. Foot & Ankle International (FAI) published higher quality studies with a higher LOE as compared to podiatry journals. Regardless of the journal, MDs produced the majority of published clinical foot and ankle research. Although improvements have been made in the quality of some clinical research, this study highlights the need for continued improvement in methodology within foot and ankle literature.

  3. Optimising Ankle Foot Orthoses for children with Cerebral Palsy walking with excessive knee flexion to improve their mobility and participation; protocol of the AFO-CP study

    Directory of Open Access Journals (Sweden)

    Kerkum Yvette L

    2013-02-01

    Full Text Available Abstract Background Ankle-Foot-Orthoses with a ventral shell, also known as Floor Reaction Orthoses (FROs, are often used to reduce gait-related problems in children with spastic cerebral palsy (SCP, walking with excessive knee flexion. However, current evidence for the effectiveness (e.g. in terms of walking energy cost of FROs is both limited and inconclusive. Much of this ambiguity may be due to a mismatch between the FRO ankle stiffness and the patient’s gait deviations. The primary aim of this study is to evaluate the effect of FROs optimised for ankle stiffness on the walking energy cost in children with SCP, compared to walking with shoes alone. In addition, effects on various secondary outcome measures will be evaluated in order to identify possible working mechanisms and potential predictors of FRO treatment success. Method/Design A pre-post experimental study design will include 32 children with SCP, walking with excessive knee flexion in midstance, recruited from our university hospital and affiliated rehabilitation centres. All participants will receive a newly designed FRO, allowing ankle stiffness to be varied into three configurations by means of a hinge. Gait biomechanics will be assessed for each FRO configuration. The FRO that results in the greatest reduction in knee flexion during the single stance phase will be selected as the subject’s optimal FRO. Subsequently, the effects of wearing this optimal FRO will be evaluated after 12–20 weeks. The primary study parameter will be walking energy cost, with the most important secondary outcomes being intensity of participation, daily activity, walking speed and gait biomechanics. Discussion The AFO-CP trial will be the first experimental study to evaluate the effect of individually optimised FROs on mobility and participation. The evaluation will include outcome measures at all levels of the International Classification of Functioning, Disability and Health, providing a unique

  4. Spanish Translation, Cross-Cultural Adaptation, and Validation of the American Academy of Orthopaedic Surgeons Foot and Ankle Outcomes Questionnaire in Mexican-Americans With Traumatic Foot and Ankle Injuries.

    Science.gov (United States)

    Zelle, Boris A; Francisco, Ben S; Bossmann, James P; Fajardo, Roberto J; Bhandari, Mohit

    2017-05-01

    Hispanics represent the largest minority group within the US population accounting for an estimated 55.4 million individuals. Enrolling Hispanics into clinical outcome studies is important in order for study populations to be externally valid and representative of the US population. Inclusion of Mexican-Americans in clinical studies is frequently limited by the lack of validated outcome measures. The goal of this study was to validate a Spanish version of the American Academy of Orthopaedic Surgeons Foot and Ankle Outcomes Questionnaire (AAOS-FAOQ) in Mexican-Americans with traumatic foot and ankle injuries. The translation and cross-cultural adaptation procedure was performed by a committee of bilingual speakers using the following steps: (1) forward translation and adaptation, (2) synthesis, (3) back translation, (4) committee review, and (5) pilot testing. The validation was performed in 100 Mexican-Americans with traumatic foot and ankle injuries. A total of 41 females and 59 males were enrolled in this study. The mean age was 42.98 years (range 18-88). The Spanish version of the Global Foot and Ankle Scale of the AAOS-FAOQ showed statistically significant correlations with all 8 subscales of the Spanish SF-36 as well as the Physical Component Summary scale and the Mental Component Summary scale (P Foot and Ankle scale of the Spanish AAOS-FAOQ demonstrated a test-retest reliability of 0.68. We provide a Spanish translation and cross-cultural adaptation of the AAOS-FAOQ. The instrument demonstrates appropriate psychometric properties in Mexican-Americans with traumatic foot and ankle injuries.

  5. Concomitant Contracture of the Knee and Ankle Joint After Gastrocnemius Muscle Rupture: A Case Report.

    Science.gov (United States)

    Ryu, Dong Jin; Kim, Joon Mee; Kim, Bom Soo

    Injury of the medial head of the gastrocnemius, also called "tennis leg," is known to heal uneventfully in most cases with compression and immobilization therapy. Failure to heal or long-term complications, including ongoing pain and pes equinus, have been documented in only a limited number of case reports. To the best of our knowledge, a severe concomitant contracture of the knee and ankle joint as a consequence of a maltreated gastrocnemius muscle rupture has not been previously reported in English-language reports. The purpose of the present study was to report a serious complication of neglected tennis leg with a review of the published data. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Spring-like Ankle Foot Orthoses reduce the energy cost of walking by taking over ankle work

    NARCIS (Netherlands)

    Bregman, D.J.J.; Harlaar, J.; Meskers, C.G.M.; de Groot, V.

    2012-01-01

    In patients with central neurological disorders, gait is often limited by a reduced ability to push off with the ankle. To overcome this reduced ankle push-off, energy-storing, spring-like carbon-composite Ankle Foot Orthoses (AFO) can be prescribed. It is expected that the energy returned by the

  7. Minimally important change was estimated for the Manchester-Oxford Foot Questionnaire after foot/ankle surgery.

    Science.gov (United States)

    Dawson, Jill; Boller, Irene; Doll, Helen; Lavis, Grahame; Sharp, Robert; Cooke, Paul; Jenkinson, Crispin

    2014-06-01

    To ascertain the smallest amounts of change for the three Manchester-Oxford Foot Questionnaire (MOXFQ) domains that are likely to be clinically meaningful and beyond measurement error for conditions affecting the foot/ankle. Estimates were compared with those from the Short-Form 36 (SF-36). A prospective observational study of 671 consecutive patients undergoing foot or ankle surgery at an orthopedic hospital. Before and 9 months after surgery, patients completed the MOXFQ and SF-36; transition items (anchor) asked about perceived changes in foot/ankle pain or problems since the surgery. Four hundred ninety-one patients completed pre- and postoperative questionnaires. Anchor-based minimal clinically important change (MCIC) values were ~13 points for each of the MOXFQ Walking/standing (W/S), Pain, and Social Interaction (S-I) domains [and greater than the standard error of measurement (SEM)]. MCIC values for all SF-36 domains fell within the SEM. Between-group MCIDs for the MOXFQ were W/S, 16.2; Pain, 9.9; S-I, 9.3. Distribution-based minimal detectable change (MDC90) values for the MOXFQ were ~11, ~12, and ~16 score points for the W/S, Pain, and S-I scales, respectively. This article provides information for aiding the interpretability of MOXFQ outcomes data and for planning future studies. The SF-36 is not recommended as a primary outcome for foot/ankle surgery. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Simultaneous bilateral total knee and ankle arthroplasty as a single surgical procedure.

    Science.gov (United States)

    Pagenstert, Geert; Hintermann, Beat

    2011-10-13

    Simultaneous osteoarthritis (OA) of the ankle joint complicates primary total knee arthroplasty (TKA). In such cases, rehabilitation of TKA is limited by debilitating ankle pain, but varus or valgus ankle arthritis may even compromise placement of knee prosthetic components. We present a patient with simultaneous bilateral valgus and patellofemoral OA of the knees and bilateral varus OA of the ankle joints that equally contributed to overall disability. This 63 years old, motivated and otherwise healthy patient was treated by simultaneous bilateral total knee and ankle arthroplasty (quadruple total joint arthroplasty, TJA) during the same anesthesia. Two years outcome showed excellent alignment and function of all four replaced joints. Postoperative time for rehabilitation, back to work (6th week) and hospital stay (12 days) of this special patient was markedly reduced compared to the usual course of separate TJA. Simultaneous quadruple TJA in equally disabling OA of bilateral deformed knees and ankles resulted in a better functional outcome and faster recovery compared to the average reported results after TKA and TAA in literature. However, careful preoperative planning, extensive patient education, and two complete surgical teams were considered essential for successful performance. To the best of our knowledge this is the first case report in literature about quadruple major total joint arthroplasty implanted during the same anesthesia in the same patient.

  9. Simultaneous bilateral total knee and ankle arthroplasty as a single surgical procedure

    Directory of Open Access Journals (Sweden)

    Hintermann Beat

    2011-10-01

    Full Text Available Abstract Background Simultaneous osteoarthritis (OA of the ankle joint complicates primary total knee arthroplasty (TKA. In such cases, rehabilitation of TKA is limited by debilitating ankle pain, but varus or valgus ankle arthritis may even compromise placement of knee prosthetic components. Case presentation We present a patient with simultaneous bilateral valgus and patellofemoral OA of the knees and bilateral varus OA of the ankle joints that equally contributed to overall disability. This 63 years old, motivated and otherwise healthy patient was treated by simultaneous bilateral total knee and ankle arthroplasty (quadruple total joint arthroplasty, TJA during the same anesthesia. Two years outcome showed excellent alignment and function of all four replaced joints. Postoperative time for rehabilitation, back to work (6th week and hospital stay (12 days of this special patient was markedly reduced compared to the usual course of separate TJA. Conclusions Simultaneous quadruple TJA in equally disabling OA of bilateral deformed knees and ankles resulted in a better functional outcome and faster recovery compared to the average reported results after TKA and TAA in literature. However, careful preoperative planning, extensive patient education, and two complete surgical teams were considered essential for successful performance. To the best of our knowledge this is the first case report in literature about quadruple major total joint arthroplasty implanted during the same anesthesia in the same patient.

  10. Epidemiology of ankle and foot overuse injuries in sports : A systematic review

    NARCIS (Netherlands)

    Sobhani, S.; Dekker, R.; Postema, K.; Dijkstra, P. U.

    2013-01-01

    Studies regarding ankle and foot overuse injuries are quite diverse in research methodology, data reporting, and outcomes. The aims of this systematic review were to analyze the methodology of published studies regarding ankle and foot overuse injuries in different sports disciplines and to

  11. Vacuum-assisted closure to aid wound healing in foot and ankle surgery.

    Science.gov (United States)

    Mendonca, Derick A; Cosker, Tom; Makwana, Nilesh K

    2005-09-01

    Although vacuum-assisted closure (VAC) is a well-established technique in other surgical specialties, its use has not been established in the foot and ankle. The aims of this study were to determine if vacuum-assisted closure therapy (VAC) helps assist closure in diabetic foot ulcers and wounds secondary to peripheral vascular disease, if it helps debride wounds, and if it prevents the need for further surgery. We retrospectively reviewed 15 patients (18 wounds or ulcers) with primary diagnoses of diabetes (10 patients), chronic osteomyelitis (two patients), peripheral vascular disease (two patients), and spina bifida (one patient). Eleven of the 15 patients had serious comorbidities, such as peripheral neuropathy, renal failure, and wound dehiscence. All wounds were surgically debrided before VAC therapy was applied according to the manufacturer's instructions. The main outcome measures were time to satisfactory wound closure, changes in the wound surface area, and the need for further surgery. Satisfactory healing was achieved in 13 of the 18 wounds or ulcers at an average of 2.5 months. VAC therapy failed in five patients (five class III ulcers), three of whom required below-knee amputations. Wound or ulcer size decreased from an average of 7.41 cm(2) before treatment to an average of 1.58 cm(2) after treatment. VAC therapy is a useful adjunct to the standard treatment of chronic wound or ulcers in patients with diabetes or peripheral vascular disease. Its use in foot and ankle surgery leads to a quicker wound closure and, in most patients, avoids the need for further surgery.

  12. Validity and Reliability of Visual Analog Scale Foot and Ankle: The Turkish Version.

    Science.gov (United States)

    Gur, Gozde; Turgut, Elif; Dilek, Burcu; Baltaci, Gul; Bek, Nilgun; Yakut, Yavuz

    The present study tested the reliability and validity of the Turkish version of the visual analog scale foot and ankle (VAS-FA) among healthy subjects and patients with foot problems. A total of 128 participants, 65 healthy subjects and 63 patients with foot problems, were evaluated. The VAS-FA was translated into Turkish and administered to the 128 subjects on 2 separate occasions with a 5-day interval. The test-retest reliability and internal consistency were assessed with the intraclass correlation coefficient and Cronbach's α. The validity was assessed using the correlations with Turkish versions of the Foot Function Index, the Foot and Ankle Outcome Score, and the Short-Form 36-item Health Survey. A statistically significant difference was found between the healthy group and the patient group in the overall score and subscale scores of the VAS-FA (p Foot Function Index, Foot and Ankle Outcome Score, and Short-Form 36-item Health Survey scores in the healthy and patient groups both. The Turkish version of the VAS-FA is sensitive enough to distinguish foot and ankle-specific pathologic conditions from asymptomatic conditions. The Turkish version of the VAS-FA is a reliable and valid method and can be used for foot-related problems. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Welcome to Journal of Foot and Ankle Research: a new open access journal for foot health professionals

    OpenAIRE

    Borthwick Alan M; Potter Mike J; Menz Hylton B; Landorf Karl B

    2008-01-01

    Abstract Journal of Foot and Ankle Research (JFAR) is a new, open access, peer-reviewed online journal that encompasses all aspects of policy, organisation, delivery and clinical practice related to the assessment, diagnosis, prevention and management of foot and ankle disorders. JFAR will cover a wide range of clinical subject areas, including diabetology, paediatrics, sports medicine, gerontology and geriatrics, foot surgery, physical therapy, dermatology, wound management, radiology, biome...

  14. Outcomes of Foot and Ankle Surgery in Diabetic Patients Who Have Undergone Solid Organ Transplantation.

    Science.gov (United States)

    Zou, Richard H; Wukich, Dane K

    2015-01-01

    Foot and ankle problems are highly prevalent in patients with diabetes mellitus (DM). Increased rates of surgical site infections and noninfectious complications, such as malunion, delayed union, nonunion, and hardware failure, have also been more commonly observed in diabetic patients who undergo foot and ankle surgery. DM is a substantial contributor of perioperative morbidity in patients with solid organ transplantation. To the best of our knowledge, postoperative foot and ankle complications have not been studied in a cohort of diabetic patients who previously underwent solid organ transplantation. The aim of the present study was to evaluate the outcomes of foot and ankle surgery in a cohort of diabetic transplant patients and to compare these outcomes with those of diabetic patients without a history of transplantation. We compared the rates of infectious and noninfectious complications after foot and ankle surgery in 28 diabetic transplant patients and 56 diabetic patients without previous transplantation and calculated the odds ratios (OR) for significant findings. The diabetic transplant patients who underwent foot and ankle surgery in the present cohort were not at an increased risk of overall complications (OR 0.83, 95% confidence interval [CI] 0.33 to 2.08, p = .67), infectious complications (OR 0.54, 95% CI 0.09 to 3.09, p = .49), or noninfectious complications (OR 1.14, 95% CI 0.41 to 3.15, p = .81). Four transplant patients (14.3%) died of non-orthopedic surgery-related events during the follow-up period; however, no deaths occurred in the control group. Diabetic patients with previous solid organ transplantation were not at an increased risk of developing postoperative complications after foot and ankle surgery, despite being immunocompromised. The transplant patients had a greater mortality rate, but their premature death was unrelated to their foot and ankle surgery. Surgeons treating transplant patients can recommend foot and ankle surgery when

  15. How can push-off be preserved during use of an ankle foot orthosis in children with hemiplegia? A prospective controlled study.

    Science.gov (United States)

    Desloovere, Kaat; Molenaers, Guy; Van Gestel, Leen; Huenaerts, Catherine; Van Campenhout, Anja; Callewaert, Barbara; Van de Walle, Patricia; Seyler, J

    2006-10-01

    Several studies indicated that walking with an ankle foot orthosis (AFO) impaired third rocker. The purpose of this study was to evaluate the effects of two types of orthoses, with similar goal settings, on gait, in a homogeneous group of children, using both barefoot and shoe walking as control conditions. Fifteen children with hemiplegia, aged between 4 and 10 years, received two types of individually tuned AFOs: common posterior leaf-spring (PLS) and Dual Carbon Fiber Spring AFO (CFO) (with carbon fibre at the dorsal part of the orthosis). Both orthoses were expected to prevent plantar flexion, thus improving first rocker, allowing dorsiflexion to improve second rocker, absorbing energy during second rocker, and returning it during the third rocker. The effect of the AFOs was studied using objective gait analysis, including 3D kinematics, and kinetics in four conditions: barefoot, shoes without AFO, and PLS and CFO combined with shoes. Several gait parameters significantly changed in shoe walking compared to barefoot walking (cadence, ankle ROM and velocity, knee shock absorption, and knee angle in swing). The CFO produced a significantly larger ankle ROM and ankle velocity during push-off, and an increased plantar flexion moment and power generation at pre-swing compared to the PLS (<0.01). The results of this study further support the findings of previous studies indicating that orthoses improve specific gait parameters compared to barefoot walking (velocity, step length, first and second ankle rocker, sagittal knee and hip ROM). However, compared to shoes, not all improvements were statistically significant.

  16. Weightbearing Computed Tomography of the Foot and Ankle: Emerging Technology Topical Review.

    Science.gov (United States)

    Barg, Alexej; Bailey, Travis; Richter, Martinus; de Cesar Netto, Cesar; Lintz, François; Burssens, Arne; Phisitkul, Phinit; Hanrahan, Christopher J; Saltzman, Charles L

    2018-03-01

    In the last decade, cone-beam computed tomography technology with improved designs allowing flexible gantry movements has allowed both supine and standing weight-bearing imaging of the lower extremity. There is an increasing amount of literature describing the use of weightbearing computed tomography in patients with foot and ankle disorders. To date, there is no review article summarizing this imaging modality in the foot and ankle. Therefore, we performed a systematic literature review of relevant clinical studies targeting the use of weightbearing computed tomography in diagnosis of patients with foot and ankle disorders. Furthermore, this review aims to offer insight to those with interest in considering possible future research opportunities with use of this technology. Level V, expert opinion.

  17. Stress fractures of the foot and ankle.

    Science.gov (United States)

    Welck, M J; Hayes, T; Pastides, P; Khan, W; Rudge, B

    2017-08-01

    Stress fractures occur as a result of microscopic injuries sustained when bone is subjected to repeated submaximal stresses. Overtime, with repeated cycles of loading, accumulation of such injuries can lead to macro-structural failure and frank fracture. There are numerous stress fractures about the foot and ankle of which a trauma and orthopaedic surgeon should be aware. These include: metatarsal, tibia, calcaneus, navicular, fibula, talus, medial malleolus, sesamoid, cuneiform and cuboid. Awareness of these fractures is important as the diagnosis is frequently missed and appropriate treatment delayed. Late identification can be associated with protracted pain and disability, and may predispose to non-union and therefore necessitate operative intervention. This article outlines the epidemiology and risk factors, aetiology, presentation and management of the range of stress fractures in the foot and ankle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Development of an Active Ankle Foot Orthosis to Prevent Foot Drop and Toe Drag in Hemiplegic Patients: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Jungyoon Kim

    2011-01-01

    Full Text Available We developed an active ankle-foot orthosis (AAFO that controls dorsiflexion/plantarflexion of the ankle joint to prevent foot drop and toe drag during hemiplegic walking. To prevent foot slap after initial contact, the ankle joint must remain active to minimize forefoot collision against the ground. During late stance, the ankle joint must also remain active to provide toe clearance and to aid with push-off. We implemented a series elastic actuator in our AAFO to induce ankle dorsiflexion/plantarflexion. The activator was controlled by signals from force sensing register (FSR sensors that detected gait events. Three dimensional gait analyses were performed for three hemiplegic patients under three different gait conditions: gait without AFO (NAFO, gait with a conventional hinged AFO that did not control the ankle joint (HAFO, and gait with the newly-developed AFO (AAFO. Our results demonstrate that our newly-developed AAFO not only prevents foot drop by inducing plantarflexion during loading response, but also prevents toe drag by facilitating plantarflexion during pre-swing and dorsiflexion during swing phase, leading to improvement in most temporal-spatial parameters. However, only three hemiplegic patients were included in this gait analysis. Studies including more subjects will be required to evaluate the functionality of our newly developed AAFO.

  19. The effect of ankle bracing on knee kinetics and kinematics during volleyball-specific tasks.

    Science.gov (United States)

    West, T; Ng, L; Campbell, A

    2014-12-01

    The purpose of this study was to examine the effects of ankle bracing on knee kinetics and kinematics during volleyball tasks. Fifteen healthy, elite, female volleyball players performed a series of straight-line and lateral volleyball tasks with no brace and when wearing an ankle brace. A 14-camera Vicon motion analysis system and AMTI force plate were used to capture the kinetic and kinematic data. Knee range of motion, peak knee anterior-posterior and medial-lateral shear forces, and peak ground reaction forces that occurred between initial contact with the force plate and toe off were compared using paired sample t-tests between the braced and non-braced conditions (P volleyball tasks. However, ankle bracing was demonstrated to reduce knee lateral shear forces during all of the lateral movement volleyball tasks. Wearing the Active Ankle T2 brace will not impact knee joint range of motion and may in fact reduce shear loading to the knee joint in volleyball players. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Psychological factors and personality traits associated with patients in chronic foot and ankle pain.

    Science.gov (United States)

    Shivarathre, Deepak Gubbi; Howard, Nicholas; Krishna, Sowmya; Cowan, Chris; Platt, Simon R

    2014-11-01

    The impact of psychosocial factors and personality traits in chronic pain is well established. However, there has been limited literature analyzing the influence of psychological issues in chronic foot and ankle pain. The aim of our study was to identify the association of certain psychosocial factors and personality traits in individuals with chronic painful foot and ankle disorders. Patients with chronic foot and ankle pain were recruited from the specialist foot and ankle clinic. The Eysenck Personality Questionnaire-Revised (EPQ-R), Dysfunctional Attitude Scale (DAS), and Hospital Anxiety Depression (HAD) scale were administered in the form of questionnaires. An age- and sex-matched cohort of healthy volunteers served as the control group. Sample size was determined after power calculation, and a total of 90 participants were recruited with informed consent with 45 participants in each arm. Results were analyzed and statistical analyses were performed using SPSS. Patients with chronic foot and ankle pain had significantly higher neuroticism scores than the control group (P pain (P pain. Clinicians should recognize the influence of these specific psychological issues to provide a more holistic approach to the clinical problem. Level III, case control study. © The Author(s) 2014.

  1. Acute fractures of the pediatric foot and ankle.

    Science.gov (United States)

    Halai, Mansur; Jamal, Bilal; Rea, Paul; Qureshi, Mobeen; Pillai, Anand

    2015-02-01

    Injuries around the foot and ankle are challenging. There is a paucity of literature, outside that of specialist orthopedic journals, that focuses on this subject in the pediatric population. In this review, we outline pediatric foot and ankle fractures in an anatomically oriented manner from the current literature. Our aim is to aid the emergency department doctor to manage these challenging injuries more effectively in the acute setting. These injuries require a detailed history and examination to aid the diagnosis. Often, plain radiographs are sufficient, but more complex injuries require the use of magnetic resonance imaging. Treatment is dependent on the proximity to skeletal maturity and the degree of displacement of fracture. Children have a marked ability to remodel after fractures and therefore mainstay treatment is immobilization by a cast or splint. Operative fixation, although uncommon in this population, may be necessary with adolescents, certain unstable injuries or in cases with displaced articular surface. In the setting of severe foot trauma, skin compromise and compartment syndrome of the foot must be excluded. The integrity of the physis, articular surface and soft tissues are all equally important in treating these injuries.

  2. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  3. Ambulatory assessment of ankle and foot dynamics

    NARCIS (Netherlands)

    Schepers, H. Martin; Koopman, Hubertus F.J.M.; Veltink, Petrus H.

    Ground reaction force (GRF) measurement is important in the analysis of human body movements. The main drawback of the existing measurement systems is the restriction to a laboratory environment. This paper proposes an ambulatory system for assessing the dynamics of ankle and foot, which integrates

  4. Repeatability of the Oxford Foot Model for Kinematic Gait Analysis of the Foot and Ankle

    NARCIS (Netherlands)

    van Hoeve, S.; Vos, J.; Weijers, P.; Verbruggen, J.; Willems, P.; Poeze, M.; Meijer, K.

    2015-01-01

    INTRODUCTION: Kinematic gait analysis via the multi-segmental Oxford foot model (OFM) may be a valuable addition to the biomechanical examination of the foot and ankle. The aim of this study is to assess the repeatability of the OFM in healthy subjects. METHODS: Nine healthy subjects, without a

  5. Management of lawn mower injuries to the foot and ankle.

    Science.gov (United States)

    Corcoran, J; Zamboni, W A; Zook, E G

    1993-09-01

    Seventy consecutive patients treated for lawn mower injuries to the foot and ankle were reviewed to determine optimal treatment, functional results, and complications. Injuries were classified into 1 or more functional-anatomical zones (I, digits; II, dorsum; III, plantar nonweight-bearing surface; IV, heel; and V, ankle) for a total of 96 injuries. Thirty-one patients were available for follow-up. Mean age was 36.7 years and 84% were males. Most injuries (67%) involved patients > 16 years old using a push mower; however, 18% involved children Lawn mower injuries to the foot and ankle can be closed primarily after adequate irrigation and debridement without compromise of infection rate or function. Antibiotic prophylaxis is recommended. One-sixth of these injuries involve children < 5 years of age and can be prevented.

  6. EFFECTS OF COMBINED FOOT/ANKLE ELECTROMYOSTIMULATION AND RESISTANCE TRAINING ON THE IN-SHOE PLANTAR PRESSURE PATTERNS DURING SPRINT IN YOUNG ATHLETES

    Directory of Open Access Journals (Sweden)

    François Fourchet

    2011-06-01

    Full Text Available Several studies have already reported that specific foot/ankle muscle reinforcement strategies induced strength and joint position sense performance enhancement. Nevertheless the effects of such protocols on sprint performance and plantar loading distribution have not been addressed yet. The objective of the study is to investigate the influence of a 5-wk foot/ankle strength training program on plantar loading characteristics during sprinting in adolescent males. Sixteen adolescent male athletes of a national training academy were randomly assigned to either a combined foot/ankle electromyostimulation and resistance training (FAST or a control (C group. FAST consisted of foot medial arch and extrinsic ankle muscles reinforcement exercises, whereas C maintained their usual training routine. Before and after training, in-shoe loading patterns were measured during 30-m running sprints using pressure sensitive insoles (right foot and divided into nine regions for analysis. Although sprint times remained unchanged in both groups from pre- to post- training (3.90 ± 0.32 vs. 3.98 ± 0.46 s in FAST and 3.83 ± 0.42 vs. 3.81 ± 0.44 s in C, changes in force and pressure appeared from heel to forefoot between FAST and C. In FAST, mean pressure and force increased in the lateral heel area from pre- to post- training (67.1 ± 44.1 vs. 82.9 ± 28.6 kPa [p = 0.06]; 25.5 ± 17.8 vs. 34.1 ± 14.3 N [p = 0.05] and did not change in the medial forefoot (151.0 ± 23.2 vs. 146.1 ± 30.0 kPa; 142.1 ± 29.4 vs. 136.0 ± 33.8; NS. Mean area increased in FAST under the lateral heel from pre- to post- (4.5 ± 1.3 vs. 5.7 ± 1.6 cm2 [p < 0.05] and remained unchanged in C (5.5 ± 2.8 vs. 5.0 ± 3.0 cm2. FAST program induced significant promising lateral and unwanted posterior transfer of the plantar loads without affecting significantly sprinting performance

  7. Management of high-energy foot and ankle injuries in the geriatric population.

    Science.gov (United States)

    Herscovici, Dolfi; Scaduto, Julia M

    2012-03-01

    By the year 2035 almost 20% of the US population of 389 million people will be 65 years and older. What this group has, compared with aged populations in the past, is better health, more mobility, and more active lifestyles. From January 1989 through December 2010, a total of 494 elderly patients with 536 foot and ankle injuries were identified. Within this group, 237 (48%) patients with 294 injuries were sustained as a result of a high-energy mechanism. These mechanisms consisted of 170 motor vehicle accidents, 30 as a result of high (not ground level) energy falls, 2 from industrial accidents, and 35 classified as other, which included sports, blunt trauma, bicycle, airplane or boating accidents, crush injuries, and injuries resulting from a lawn mower. The injuries produced were 17 metatarsal fractures, 9 Lisfranc injuries, 10 midfoot (navicular, cuneiform, or cuboid) fractures, 23 talus fractures, 63 calcaneal fractures, 73 unimalleolar, bimalleolar, or trimalleolar ankle fractures, 45 pilon fractures, and 3 pure dislocations of the foot or ankle. Overall, 243 (83%) of these injuries underwent surgical fixation and data have shown that when surgery is used to manage high-energy injuries of the foot and ankle in the elderly individuals, the complications and outcomes are similar to those seen in younger patients. Therefore, the decision for surgical intervention for high-energy injuries of the foot and ankle should be based primarily on the injury pattern and not solely on the age of the patient.

  8. Responses of spinal dorsal horn neurons to foot movements in rats with a sprained ankle

    Science.gov (United States)

    Kim, Jae Hyo; Kim, Hee Young; Chung, Kyungsoon

    2011-01-01

    Acute ankle injuries are common problems and often lead to persistent pain. To investigate the underlying mechanism of ankle sprain pain, the response properties of spinal dorsal horn neurons were examined after ankle sprain. Acute ankle sprain was induced manually by overextending the ankle of a rat hindlimb in a direction of plantarflexion and inversion. The weight-bearing ratio (WBR) of the affected foot was used as an indicator of pain. Single unit activities of dorsal horn neurons in response to plantarflexion and inversion of the foot or ankle compression were recorded from the medial part of the deep dorsal horn, laminae IV-VI, in normal and ankle-sprained rats. One day after ankle sprain, rats showed significantly reduced WBRs on the affected foot, and this reduction was partially restored by systemic morphine. The majority of deep dorsal horn neurons responded to a single ankle stimulus modality. After ankle sprain, the mean evoked response rates were significantly increased, and afterdischarges were developed in recorded dorsal horn neurons. The ankle sprain-induced enhanced evoked responses were significantly reduced by morphine, which was reversed by naltrexone. The data indicate that movement-specific dorsal horn neuron responses were enhanced after ankle sprain in a morphine-dependent manner, thus suggesting that hyperactivity of dorsal horn neurons is an underlying mechanism of pain after ankle sprain. PMID:21389306

  9. Knee joint kinetics in response to multiple three-dimensional printed, customised foot orthoses for the treatment of medial compartment knee osteoarthritis.

    Science.gov (United States)

    Allan, Richard; Woodburn, James; Telfer, Scott; Abbott, Mandy; Steultjens, Martijn Pm

    2017-06-01

    The knee adduction moment is consistently used as a surrogate measure of medial compartment loading. Foot orthoses are designed to reduce knee adduction moment via lateral wedging. The 'dose' of wedging required to optimally unload the affected compartment is unknown and variable between individuals. This study explores a personalised approach via three-dimensional printed foot orthotics to assess the biomechanical response when two design variables are altered: orthotic length and lateral wedging. Foot orthoses were created for 10 individuals with symptomatic medial knee osteoarthritis and 10 controls. Computer-aided design software was used to design four full and four three-quarter-length foot orthoses per participant each with lateral posting of 0° 'neutral', 5° rearfoot, 10° rearfoot and 5° forefoot/10° rearfoot. Three-dimensional printers were used to manufacture all foot orthoses. Three-dimensional gait analyses were performed and selected knee kinetics were analysed: first peak knee adduction moment, second peak knee adduction moment, first knee flexion moment and knee adduction moment impulse. Full-length foot orthoses provided greater reductions in first peak knee adduction moment (p = 0.038), second peak knee adduction moment (p = 0.018) and knee adduction moment impulse (p = 0.022) compared to three-quarter-length foot orthoses. Dose effect of lateral wedging was found for first peak knee adduction moment (p knee adduction moment (p knee adduction moment impulse (p knee adduction moment (p = 0.028) and knee adduction moment impulse (p = 0.036). Significant interaction effects were found between orthotic length and wedging condition for second peak knee adduction moment (p = 0.002). No significant changes in first knee flexion moment were found. Individual heterogeneous responses to foot orthosis conditions were observed for first peak knee adduction moment, second peak knee adduction moment and knee adduction moment impulse. Biomechanical response

  10. One- and multi-segment foot models lead to opposite results on ankle joint kinematics during gait: Implications for clinical assessment.

    Science.gov (United States)

    Pothrat, Claude; Authier, Guillaume; Viehweger, Elke; Berton, Eric; Rao, Guillaume

    2015-06-01

    Biomechanical models representing the foot as a single rigid segment are commonly used in clinical or sport evaluations. However, neglecting internal foot movements could lead to significant inaccuracies on ankle joint kinematics. The present study proposed an assessment of 3D ankle kinematic outputs using two distinct biomechanical models and their application in the clinical flat foot case. Results of the Plug in Gait (one segment foot model) and the Oxford Foot Model (multisegment foot model) were compared for normal children (9 participants) and flat feet children (9 participants). Repeated measures of Analysis of Variance have been performed to assess the Foot model and Group effects on ankle joint kinematics. Significant differences were observed between the two models for each group all along the gait cycle. In particular for the flat feet group, opposite results between the Oxford Foot Model and the Plug in Gait were revealed at heelstrike, with the Plug in Gait showing a 4.7° ankle dorsal flexion and 2.7° varus where the Oxford Foot Model showed a 4.8° ankle plantar flexion and 1.6° valgus. Ankle joint kinematics of the flat feet group was more affected by foot modeling than normal group. Foot modeling appeared to have a strong influence on resulting ankle kinematics. Moreover, our findings showed that this influence could vary depending on the population. Studies involving ankle joint kinematic assessment should take foot modeling with caution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Differences in injury pattern and prevalence of cartilage lesions in knee and ankle joints: a retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Matthias Aurich

    2014-12-01

    Full Text Available Osteoarthritis (OA is more common in the knee compared to the ankle joint. This can not be explained exclusively by anatomical and biomechanical differences. The aim of this study is to analyze and compare the injury pattern (clinically and the cartilage lesions (arthroscopically of knee and ankle joints in a cohort of patients from the same catchment area. A retrospective study of the clinical data of 3122 patients (2139 outpatients and 983 inpatients was performed, who were treated due to an injury of the knee and ankle joint. Statistical analysis was performed using SigmaStat 3.0 (SPSS Inc, Chicago, USA. There is a higher prevalence of injuries in the ankle as compared to the knee joint in this population from the same catchment area. In contrast, high-grade cartilage lesions are more prevalent in the knee, whereas low grade cartilage lesions are equally distributed between knee and ankle. From this data it can be concluded that the frequency of injuries and the injury pattern of knee versus ankle joints do not correlate with the severity of cartilage lesions and may therefore have no direct influence on the differential incidence of OA in those two joints.

  12. Mechanical energy profiles of the combined ankle-foot system in normal gait: insights for prosthetic designs.

    Science.gov (United States)

    Takahashi, Kota Z; Stanhope, Steven J

    2013-09-01

    Over the last half-century, the field of prosthetic engineering has continuously evolved with much attention being dedicated to restoring the mechanical energy properties of ankle joint musculatures during gait. However, the contributions of 'distal foot structures' (e.g., foot muscles, plantar soft tissue) have been overlooked. Therefore, the purpose of this study was to quantify the total mechanical energy profiles (e.g., power, work, and work-ratio) of the natural ankle-foot system (NAFS) by combining the contributions of the ankle joint and all distal foot structures during stance in level-ground steady state walking across various speeds (0.4, 0.6, 0.8 and 1.0 statures/s). The results from eleven healthy subjects walking barefoot indicated ankle joint and distal foot structures generally performed opposing roles: the ankle joint performed net positive work that systematically increased its energy generation with faster walking speeds, while the distal foot performed net negative work that systematically increased its energy absorption with faster walking speeds. Accounting for these simultaneous effects, the combined ankle-foot system exhibited increased work-ratios with faster walking. Most notably, the work-ratio was not significantly greater than 1.0 during the normal walking speed of 0.8 statures/s. Therefore, a prosthetic design that strategically exploits passive-dynamic properties (e.g., elastic energy storage and return) has the potential to replicate the mechanical energy profiles of the NAFS during level-ground steady-state walking. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. The Comparison of Ankle Muscles Isometric Strength and Foot Eversion in Male Individuals with Patellofemoral Pain Syndrome and Healthy Peers: A Case-Control Study

    Directory of Open Access Journals (Sweden)

    V. Mazloum

    2017-01-01

    Full Text Available Introduction: Proximal and distal factors to the knee joint can be assumed as etiology of patellofemoral pain syndrome (PFPS. Some distal factors include excessive foot pronation and medial tibia torsion. The purpose of this study was to compare ankle musculature strength and rearfoot eversion in individuals with and without PFPS. Methods: Forty males (20 healthy and 20 patients voluntarily participated in this case-control study. Isometric ankle dorsiflexor and invertor muscles strength, rearfoot eversion range of motion (ROM, and Navicular depression were respectively evaluated by handheld dynamometer, goniometry, and Navicular Drop Test by a single examiner for both groups. To analyze the measurements, Independent Samples t test for parametric data and Mann-Whitney U test for nonparametric data at P0.05. Furthermore, no significant differences were observed between patients with PFPS and healthy counterparts regarding rearfoot eversion and Navicular depression (P>0.05. Conclusion: It can be deduced that isometric ankle dorsiflexor and invertor muscles strength, rearfoot eversion ROM, and foot pronation are not difference in patients with PFPS and healthy persons. 

  14. Weight transfer analysis in adults with hemiplegia using ankle foot orthosis.

    Science.gov (United States)

    Nolan, Karen J; Yarossi, Mathew

    2011-03-01

    Identifying and understanding the changes in transfer of momentum that are directly affected by orthotic intervention are significant factors related to the improvement of mobility in individuals with hemiplegia. The purpose of this investigation was to use a novel analysis technique to objectively measure weight transfer during double support (DS) in healthy individuals and individuals with hemiplegia secondary to stroke with and without an ankle foot orthosis. Prospective, Repeated measures, case-controlled trial. Participants included 25 adults with stroke-related hemiplegia >6 months using a prescribed ankle foot orthosis and 12 age-matched healthy controls. Main outcome measures included the weight transfer point timing (WTP, %DS), maximum total force timing (MTF, %DS), timing difference between WTP and MTF (MTF-WTP, %DS) and the linearity of loading (LOL, R(2)) during the DS phase of the gait cycle. The WTP and LOL were significantly different between conditions with and without the ankle foot orthosis for the affected and unaffected limb in post-stroke individuals, p ≤ 0.01. The MTF and difference in timing between MTF-WTP were significantly different during affected limb loading with and without the ankle foot orthosis in the stroke group, p ≤ 0.0001 and p = 0.03, respectively. MTF, MTF-WTP and LOL were significantly different between individuals with stroke (during affected limb loading) and healthy controls (during right limb loading). This research established a systematic method for analysing weight transfer during walking to evaluate the effect of an ankle foot orthosis on loading during double support in hemiplegic gait. This novel method can be used to elucidate biomechanical mechanisms behind orthosis-mediated changes in gait patterns and quantify functional mobility outcomes in rehabilitation. This novel approach to orthotic assessment will provide the clinician with needed objective evidence to select the most effective orthotic

  15. Management of foot and ankle injuries in pediatric and adolescent athletes: a narrative review

    Directory of Open Access Journals (Sweden)

    Gill LE

    2018-04-01

    Full Text Available Laura E Gill,1,2 Kevin E Klingele,1,2 1Department of Orthopedic Surgery, Nationwide Children’s Hospital, Columbus, OH, USA; 2Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, OH, USA Abstract: In this review, we focus on the treatment of injuries to the foot and ankle in the adolescent athlete. While many injuries in the adolescent foot and ankle are similar to or overlap with their counterparts in the adult population, the anatomy of the adolescent ankle, especially the presence of growth plates, results in different injury patterns in many cases and calls for specific management approaches. We discuss the unique anatomy of the pediatric patient as well as the diagnostic evaluation and treatment of common injuries in the young athlete. Keywords: foot, ankle, lower extremity, pediatric athlete, growth plate, Lisfranc injury 

  16. Comparison of the Otto Bock solid ankle cushion heel foot with wooden keel to the low-cost CR-Equipements™ solid ankle cushion heel foot with polypropylene keel: A randomized prospective double-blind crossover study assessing patient satisfaction and energy expenditure.

    Science.gov (United States)

    Lacraz, Alain; Armand, Stéphane; Turcot, Katia; Carmona, Gorki; Stern, Richard; Borens, Olivier; Assal, Mathieu

    2017-06-01

    The International Committee of the Red Cross supports a worldwide program of prosthetic fitting and rehabilitation. In this context, a prosthetic foot was developed and widely distributed in least developed countries. Prospective, randomized, double-blind, controlled study. To compare patient satisfaction and energy expenditure during ambulation between a low-cost prosthetic foot designed with a polypropylene keel (CR-Equipements ™ solid ankle cushion heel, International Committee of the Red Cross) to a well-recognized solid ankle cushion heel foot with a wooden keel (solid ankle cushion heel foot, Otto Bock). A total of 15 participants with unilateral transtibial amputation were evaluated using the two prosthetic feet in a randomized prospective double-blind crossover study. Main outcomes were patient satisfaction questionnaires (Satisfaction with Prosthesis Questionnaire and prosthetic foot satisfaction) and energy expenditure (oxygen consumption-mL/kg/min, oxygen cost-mL/kg/m, and heart rate-bpm). There were no significant differences between the two prosthetic feet for satisfaction and energy expenditure. The low-cost solid ankle cushion heel foot with polypropylene keel provides comparable satisfaction and similar energy expenditure as the solid ankle cushion heel foot with wooden keel. Clinical relevance The results of this study support the application and widespread use of the CR-Equipements ™ solid ankle cushion heel foot. From a cost-effectiveness standpoint, patients are well satisfied and exhibit similar outcomes at a substantially lower cost.

  17. Effect of ankle-foot orthoses on walking efficiency and gait in children with cerebral palsy

    NARCIS (Netherlands)

    Brehm, M.A.; Harlaar, J.; Schwartz, M.

    2008-01-01

    Objective: To determine the effect of ankle-foot orthoses on walking efficiency and gait in a heterogeneous group of children with cerebral palsy, using barefoot walking as the control condition. Design: A retrospective study. Methods: Barefoot and ankle-foot orthosis data for 172 children with

  18. Reliability and validity of the Dutch version of the foot and ankle outcome score (FAOS)

    NARCIS (Netherlands)

    van den Akker-Scheek, Inge; Seldentuis, Arnoud; Reininga, Inge H. F.; Stevens, Martin

    2013-01-01

    Background: The Foot and Ankle Outcome Score (FAOS) is a patient-reported questionnaire measuring symptoms and functional limitations of the foot and ankle. Aim is to translate and culturally adapt the Dutch version of the FAOS and to investigate internal consistency, validity, repeatability and

  19. Application of the Superelastic NiTi Spring in Ankle Foot Orthosis (AFO to Create Normal Ankle Joint Behavior

    Directory of Open Access Journals (Sweden)

    Amirhesam Amerinatanzi

    2017-12-01

    Full Text Available Hinge-based Ankle Foot Orthosis (HAFO is one of the most common non-surgical solutions for the foot drop. In conventional HAFOs, the ankle joint is almost locked, and plantar flexion is restricted due to the high stiffness of the hinge mechanism. This often leads to a rigid walking gate cycle, poor muscle activity, and muscle atrophy. Since the ankle torque-angle loop has a non-linear profile, the use of a superelastic NiTi spring within the hinge, due to its nonlinear behavior, could recreate a close-to-normal stiffness of the normal ankle joint, which, in turn, could create a more natural walk. The focus of this study is to evaluate the performance of a superelastic NiTi spring versus a conventional Stainless Steel spring in a hinge mechanism of a custom-fit HAFO. To this aim, a custom-fit HAFO was fabricated via the fast casting technique. Then, motion analysis was performed for two healthy subjects (Case I and Case II: (i subjects with bare foot; (ii subjects wearing a conventional HAFO with no spring; (iii subjects wearing a conventional Stainless Steel-based HAFO; and (iv subjects wearing a NiTi spring-based HAFO. The data related to the ankle angle and the amount of moment applied to the ankle during walking were recorded using Cortex software and used for the evaluations. Finally, Finite Element Analysis (FEA was performed to evaluate the safety of the designed HAFO. The NiTi spring offers a higher range of motion (7.9 versus 4.14 degree and an increased level of moment (0.55 versus 0.36 N·m/kg. Furthermore, a NiTi spring offers an ankle torque-angle loop closer to that of the healthy subjects.

  20. Application of the Superelastic NiTi Spring in Ankle Foot Orthosis (AFO) to Create Normal Ankle Joint Behavior.

    Science.gov (United States)

    Amerinatanzi, Amirhesam; Zamanian, Hashem; Shayesteh Moghaddam, Narges; Jahadakbar, Ahmadreza; Elahinia, Mohammad

    2017-12-07

    Hinge-based Ankle Foot Orthosis (HAFO) is one of the most common non-surgical solutions for the foot drop. In conventional HAFOs, the ankle joint is almost locked, and plantar flexion is restricted due to the high stiffness of the hinge mechanism. This often leads to a rigid walking gate cycle, poor muscle activity, and muscle atrophy. Since the ankle torque-angle loop has a non-linear profile, the use of a superelastic NiTi spring within the hinge, due to its nonlinear behavior, could recreate a close-to-normal stiffness of the normal ankle joint, which, in turn, could create a more natural walk. The focus of this study is to evaluate the performance of a superelastic NiTi spring versus a conventional Stainless Steel spring in a hinge mechanism of a custom-fit HAFO. To this aim, a custom-fit HAFO was fabricated via the fast casting technique. Then, motion analysis was performed for two healthy subjects (Case I and Case II): (i) subjects with bare foot; (ii) subjects wearing a conventional HAFO with no spring; (iii) subjects wearing a conventional Stainless Steel-based HAFO; and (iv) subjects wearing a NiTi spring-based HAFO. The data related to the ankle angle and the amount of moment applied to the ankle during walking were recorded using Cortex software and used for the evaluations. Finally, Finite Element Analysis (FEA) was performed to evaluate the safety of the designed HAFO. The NiTi spring offers a higher range of motion (7.9 versus 4.14 degree) and an increased level of moment (0.55 versus 0.36 N·m/kg). Furthermore, a NiTi spring offers an ankle torque-angle loop closer to that of the healthy subjects.

  1. Foot and Ankle Kinematics During Descent From Varying Step Heights.

    Science.gov (United States)

    Gerstle, Emily E; O'Connor, Kristian; Keenan, Kevin G; Cobb, Stephen C

    2017-12-01

    In the general population, one-third of incidences during step negotiation occur during the transition to level walking. Furthermore, falls during curb negotiation are a common cause of injury in older adults. Distal foot kinematics may be an important factor in determining injury risk associated with transition step negotiation. The purpose of this study was to identify foot and ankle kinematics of uninjured individuals during descent from varying step heights. A 7-segment foot model was used to quantify kinematics as participants walked on a level walkway, stepped down a single step (heights: 5 cm, 15 cm, 25 cm), and continued walking. As step height increased, landing strategy transitioned from the rearfoot to the forefoot, and the rearfoot, lateral and medial midfoot, and medial forefoot became more plantar flexed. During weight acceptance, sagittal plane range of motion of the rearfoot, lateral midfoot, and medial and lateral forefoot increased as step height increased. The changes in landing strategy and distal foot function suggest a less stable ankle position at initial contact and increased demand on the distal foot at initial contact and through the weight acceptance phase of transition step negotiation as step height increases.

  2. Comparison of energy efficiency between Wearable Power-Assist Locomotor (WPAL) and two types of knee-ankle-foot orthoses with a medial single hip joint (MSH-KAFO).

    Science.gov (United States)

    Yatsuya, Kanan; Hirano, Satoshi; Saitoh, Eiichi; Tanabe, Shigeo; Tanaka, Hirotaka; Eguchi, Masayuki; Katoh, Masaki; Shimizu, Yasuhiro; Uno, Akito; Kagaya, Hitoshi

    2018-01-01

    To compare the energy efficiency of Wearable Power-Assist Locomotor (WPAL) with conventional knee-ankle-foot orthoses (MSH-KAFO) such as Hip and Ankle Linked Orthosis (HALO) or Primewalk. Cross over case-series. Chubu Rosai Hospital, Aichi, Japan, which is affiliated with the Japan Organization of Occupational Health and Safety. Six patients were trained with MSH-KAFO (either HALO or Primewalk) and WPAL. They underwent 6-minute walk tests with each orthosis. Energy efficiency was estimated using physiological cost index (PCI) as well as heart rate (HR) and modified Borg score. Trial energy efficiency with MSH-KAFO was compared with WPAL to assess if differences in PCI became greater between MSH-KAFO and WPAL as time goes on during the 6-minute walk. Spearman correlation coefficient of time (range: 0.5-6.0 minutes) with the difference was calculated. The same statistical procedures were repeated for HR and modified Borg score. Greater energy efficiency, representing a lower gait demand, was observed in trials with WPAL compared with MSH-KAFO (Spearman correlation coefficients for PCI, HR and modified Borg were 0.93, 0.90 and 0.97, respectively, all P energy efficient type of robotics that may be used by patients with paraplegia.

  3. Stabilization of a three-dimensional limit cycle walking model through step-to-step ankle control.

    Science.gov (United States)

    Kim, Myunghee; Collins, Steven H

    2013-06-01

    Unilateral, below-knee amputation is associated with an increased risk of falls, which may be partially related to a loss of active ankle control. If ankle control can contribute significantly to maintaining balance, even in the presence of active foot placement, this might provide an opportunity to improve balance using robotic ankle-foot prostheses. We investigated ankle- and hip-based walking stabilization methods in a three-dimensional model of human gait that included ankle plantarflexion, ankle inversion-eversion, hip flexion-extension, and hip ad/abduction. We generated discrete feedback control laws (linear quadratic regulators) that altered nominal actuation parameters once per step. We used ankle push-off, lateral ankle stiffness and damping, fore-aft foot placement, lateral foot placement, or all of these as control inputs. We modeled environmental disturbances as random, bounded, unexpected changes in floor height, and defined balance performance as the maximum allowable disturbance value for which the model walked 500 steps without falling. Nominal walking motions were unstable, but were stabilized by all of the step-to-step control laws we tested. Surprisingly, step-by-step modulation of ankle push-off alone led to better balance performance (3.2% leg length) than lateral foot placement (1.2% leg length) for these control laws. These results suggest that appropriate control of robotic ankle-foot prosthesis push-off could make balancing during walking easier for individuals with amputation.

  4. Use of and Satisfaction with Ankle Foot Orthoses

    NARCIS (Netherlands)

    Joost van Hoof; Eveline Wouters; Yvonne van Zaalen; F.C. Holtkamp; M.J. Verkerk

    2015-01-01

    Objective: The aim of this study was to obtain insight in specific elements influencing the use, non-use, satisfaction, and dissatisfaction of ankle foot orthoses (AFOs) and the presence of underexposed problems with respect to AFOs. Methods: A questionnaire was composed to obtain information from

  5. Use of and satisfaction with ankle foot orthoses

    NARCIS (Netherlands)

    Holtkamp, F.C.; Wouters, E.J.M.; van Hoof, J.; van Zaalen, Y.; Verkerk, M.

    2015-01-01

    Objective: The aim of this study was to obtain insight in specific elements influencing the use, non-use, satisfaction, and dissatisfaction of ankle foot orthoses (AFOs) and the presence of underexposed problems with respect to AFOs. Methods: A questionnaire was composed to obtain information from

  6. Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis.

    Science.gov (United States)

    Gordon, Keith E; Sawicki, Gregory S; Ferris, Daniel P

    2006-01-01

    We developed a powered ankle-foot orthosis that uses artificial pneumatic muscles to produce active plantar flexor torque. The purpose of this study was to quantify the mechanical performance of the orthosis during human walking. Three subjects walked at a range of speeds wearing ankle-foot orthoses with either one or two artificial muscles working in parallel. The orthosis produced similar total peak plantar flexor torque and network across speeds independent of the number of muscles used. The orthosis generated approximately 57% of the peak ankle plantar flexor torque during stance and performed approximately 70% of the positive plantar flexor work done during normal walking. Artificial muscle bandwidth and force-length properties were the two primary factors limiting torque production. The lack of peak force and work differences between single and double muscle conditions can be explained by force-length properties. Subjects altered their ankle kinematics between conditions resulting in changes in artificial muscle length. In the double muscle condition greater plantar flexion yielded shorter artificial muscles lengths and decreased muscle forces. This finding emphasizes the importance of human testing in the design and development of robotic exoskeleton devices for assisting human movement. The results of this study outline the mechanical performance limitations of an ankle-foot orthosis powered by artificial pneumatic muscles. This orthosis could be valuable for gait rehabilitation and for studies investigating neuromechanical control of human walking.

  7. The Dutch version of the Oxford Ankle and Foot Questionnaire for Children: Useful for evaluation of pediatric foot problems in groups.

    Science.gov (United States)

    Burger, Elise; Selles, Ruud; van Nieuwkasteele, Shelly; Bessems, Gert; Pollet, Virginie; Hovius, Steven; van Nieuwenhoven, Christianne

    2017-11-04

    The purpose of this study is to develop a Dutch version of the Oxford Ankle and Foot Questionnaire for Children (OxAFQ-c) to allow evaluation of pediatric foot care. The OxAFQ-c was translated into Dutch, according to the ISPOR-guidelines. Children with different foot and ankle complaints completed the OxAFQ-c at baseline, after two weeks, and after 4-6 months. Measurement properties were assessed in terms of reliability, responsiveness, and construct validity. Test-retest reliability showed moderate intraclass correlation coefficients. Bland-Altman plots showed wide limits of agreement. After 4-6 months, the group that experienced improvement also showed improved questionnaire outcomes, indicating responsiveness. Moderate correlation between the OxAFQ-c and the Kidscreen and foot-specific VAS-scores were observed, indicating moderate construct validity. The Dutch OxAFQ-c showed moderate to good measurement properties. However, because we observed limited sensitivity to changes and wide limits of agreement in individual patients, we think the questionnaire should only be used in groups. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  8. The role of the reversed oblique radiograph in trauma of the foot and ankle

    International Nuclear Information System (INIS)

    Geusens, E.; Geyskens, W.; Brys, P.; Janzing, H.

    2000-01-01

    The objective of this study was to demonstrate the statistical significance of a reversed oblique radiograph of the foot in patients with ankle or foot trauma. In 100 consecutive patients a reversed oblique radiograph of the foot was taken in addition to the conventional plain films. Ten of 29 fractures were not visualised on the conventional films of foot and ankle and could only be diagnosed on the reversed oblique film. In 7 of these 10 cases an avulsion fracture at the anterolateral aspect of the calcaneus was present. This additional reversed oblique film of the foot seems to be of considerable importance, especially when an anterolateral avulsion fracture of the calcaneus is clinically suspected. (orig.)

  9. The role of the reversed oblique radiograph in trauma of the foot and ankle

    Energy Technology Data Exchange (ETDEWEB)

    Geusens, E.; Geyskens, W.; Brys, P. [Dept. of Radiology, University Hospitals, Leuven (Belgium); Janzing, H. [Dept. of Traumatology, University Hospitals, Leuven (Belgium)

    2000-03-01

    The objective of this study was to demonstrate the statistical significance of a reversed oblique radiograph of the foot in patients with ankle or foot trauma. In 100 consecutive patients a reversed oblique radiograph of the foot was taken in addition to the conventional plain films. Ten of 29 fractures were not visualised on the conventional films of foot and ankle and could only be diagnosed on the reversed oblique film. In 7 of these 10 cases an avulsion fracture at the anterolateral aspect of the calcaneus was present. This additional reversed oblique film of the foot seems to be of considerable importance, especially when an anterolateral avulsion fracture of the calcaneus is clinically suspected. (orig.)

  10. The effect of age and speed on foot and ankle kinematics assessed using a 4-segment foot model.

    Science.gov (United States)

    van Hoeve, Sander; Leenstra, Bernard; Willems, Paul; Poeze, Martijn; Meijer, Kenneth

    2017-09-01

    The effects of age and speed on foot and ankle kinematics in gait studies using foot models are not fully understood, whereas this can have significant influence. We analyzed these variables with the 4-segment Oxford foot model. Twenty-one healthy subjects (aged 20-65 years) were recruited for gait analysis. The effect of speed on foot and ankle kinematics was assessed by comparing results during slow walking and fast walking. To assess the effect of age, a group of 13 healthy young adults (aged 20-24 years) were compared with a group of 8 older adults (aged 53-65 years). Also, the interaction between age and speed was analyzed. Regarding speed, there was a significant difference between forefoot/hindfoot motion in the sagittal plane (flexion/extension) during both loading- and push-off phase (P = .004, P < .001). Between hindfoot/tibia, there was a significant difference for all parameters except for motion in the sagittal plane (flexion/extension) during push-off phase (P = .5). Age did not significantly influence kinematics. There was no interaction between age and speed. Our analysis found that speed significantly influenced the kinematic outcome parameters. This was more pronounced in the ankle joint. In contrast, no significant differences were found between younger and older healthy subjects.

  11. The effect of age and speed on foot and ankle kinematics assessed using a 4-segment foot model

    Science.gov (United States)

    van Hoeve, Sander; Leenstra, Bernard; Willems, Paul; Poeze, Martijn; Meijer, Kenneth

    2017-01-01

    Abstract Background: The effects of age and speed on foot and ankle kinematics in gait studies using foot models are not fully understood, whereas this can have significant influence. We analyzed these variables with the 4-segment Oxford foot model. Methods: Twenty-one healthy subjects (aged 20–65 years) were recruited for gait analysis. The effect of speed on foot and ankle kinematics was assessed by comparing results during slow walking and fast walking. To assess the effect of age, a group of 13 healthy young adults (aged 20–24 years) were compared with a group of 8 older adults (aged 53–65 years). Also, the interaction between age and speed was analyzed. Results: Regarding speed, there was a significant difference between forefoot/hindfoot motion in the sagittal plane (flexion/extension) during both loading- and push-off phase (P = .004, P push-off phase (P = .5). Age did not significantly influence kinematics. There was no interaction between age and speed. Conclusion: Our analysis found that speed significantly influenced the kinematic outcome parameters. This was more pronounced in the ankle joint. In contrast, no significant differences were found between younger and older healthy subjects. PMID:28858109

  12. Geometric design of a passive mechanical knee for lower extremity wearable devices based on anthropomorphic foot task geometry scaling

    OpenAIRE

    Ghosh, S; Robson, N; McCarthy, JM

    2015-01-01

    Copyright © 2015 by ASME. The standard recovery treatment for ankle and lower leg injuries consists of using underarm crutches. Hands-free crutches have recently emerged as a more comfortable, natural and energy efficient alternative. However in the currently available devices such as the iWalk-Free (iWALKFree, Inc., USA) the lack of a knee joint results in abnormal motion pattern at the hip and pelvic joints to ensure foot clearance during the swing phase of the gait. To address this shortco...

  13. Relationships between the center of pressure and the movements of the ankle and knee joints during the stance phase in patients with severe medial knee osteoarthritis.

    Science.gov (United States)

    Fukaya, Takashi; Mutsuzaki, Hirotaka; Okubo, Tomoyuki; Mori, Koichi; Wadano, Yasuyoshi

    2016-08-01

    The knee joint movement during the stance phase is affected by altered ankle movement and the center of pressure (COP). However the relationships between changes in the center of pressure (COP) and the altered kinematics and kinetics of the ankle and knee joints in patients with osteoarthritis (OA) of the knee are not well understood. The purpose of this study was to determine the relationships between changes in the COP and the altered kinematic and kinetic variables in ankle and knee joints during the stance phase in patients with medial knee OA. Fourteen patients with knee OA (21 knees) and healthy subjects were assessed by gait analysis using an eight-camera motion analysis system to record forward and lateral shifts in the COP and the angle and net internal moments of the knee and ankle joint. Spearman rank-correlation coefficients were used to determine the relationship between these results. In knees with medial OA, lateral shifts in the COP were correlated with knee flexion angle. Lateral shifts in the COP were correlated with the second peak of the knee extensor moment and correlated with the knee abductor moment. In patients with medial knee OA, lateral shifts in the COP were negatively correlated with the kinematic and kinetic variables in the sagittal plane of the knee joints. Controlling such lateral shifts in the COP may thus be an effective intervention for mechanical loads on the knee during the stance phase in patients with knee OA. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Managing dislocations of the hip, knee, and ankle in the emergency department

    Science.gov (United States)

    Arnold, Caylyne; Fayos, Zane; Bruner, David; Arnold, Dylan

    2017-12-01

    Dislocation of the major joints of the lower extremities--hip, knee, and ankle--can occur due to motor-vehicle crashes, falls, and sports injuries. Hip dislocations are the most common, and they require emergent management to prevent avascular necrosis of the femoral head. Knee dislocations are uncommon but potentially dangerous injuries that can result in amputation due to the potential for missed secondary injury, especially if they are reduced spontaneously. Isolated ankle dislocations are relatively rare, as most ankle dislocations involve an associated fracture. This review presents an algorithmic approach to management that ensures that pain relief, imaging, reduction, vascular monitoring, and emergent orthopedic consultation are carried out in a timely fashion. Copyright © 2017 EB Medicine. All rights reserved.

  15. Motion of the foot and ankle during the stance phase in rats

    NARCIS (Netherlands)

    Varejao, ASP; Cabrita, AM; Meek, MF; Bulas-Cruz, J; Gabriel, RC; Filipe, VM; Melo-Pinto, P; Winter, DA

    2002-01-01

    Computerized analysis of rat gait is becoming an invaluable technique used by some peripheral nerve investigators for the evaluation of function. In this article we describe the use of a biomechanical model of the foot and ankle that allows a quantitative assessment and description of the ankle

  16. Imaging in the assessment and management of overuse injuries in the foot and ankle.

    Science.gov (United States)

    Teh, James; Suppiah, Ravi; Sharp, Robert; Newton, Julia

    2011-02-01

    Overuse injuries of the ankle and foot are common in the general and athletic populations. The wide spectrum of overuse injuries includes ligamentous injuries, soft tissue and osseous impingement, osteochondral lesions, tendon injuries, and stress fractures. Some conditions such as impingement syndromes and stress fractures may be missed on initial physical examination, and patients with such injuries often present to a sports or orthopedic clinic with persistent symptoms. With the increasing participation in sports, health-care professionals involved in the care of athletes at all levels must have a thorough understanding of overuse conditions of the foot and ankle, and the use of imaging in the management of these conditions. This article covers the clinical presentation, pertinent anatomy, imaging features, and management of overuse injuries of the foot and ankle. © Thieme Medical Publishers.

  17. The forgotten foot - an assessment of foot and ankle radiograph pathology in final year medical students.

    LENUS (Irish Health Repository)

    Groarke, P J

    2014-04-27

    It has been shown that doctors in Emergency Departments (EDs) have inconsistent knowledge of musculoskeletal anatomy. This is most likely due to a deficiency in focused musculoskeletal modules at undergraduate level in medical school. The aims of this study were to evaluate the knowledge of final year medical students on foot anatomy and common foot and ankle pathology as seen on radiographs.

  18. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    Science.gov (United States)

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  19. A generic analytical foot rollover model for predicting translational ankle kinematics in gait simulation studies.

    Science.gov (United States)

    Ren, Lei; Howard, David; Ren, Luquan; Nester, Chris; Tian, Limei

    2010-01-19

    The objective of this paper is to develop an analytical framework to representing the ankle-foot kinematics by modelling the foot as a rollover rocker, which cannot only be used as a generic tool for general gait simulation but also allows for case-specific modelling if required. Previously, the rollover models used in gait simulation have often been based on specific functions that have usually been of a simple form. In contrast, the analytical model described here is in a general form that the effective foot rollover shape can be represented by any polar function rho=rho(phi). Furthermore, a normalized generic foot rollover model has been established based on a normative foot rollover shape dataset of 12 normal healthy subjects. To evaluate model accuracy, the predicted ankle motions and the centre of pressure (CoP) were compared with measurement data for both subject-specific and general cases. The results demonstrated that the ankle joint motions in both vertical and horizontal directions (relative RMSE approximately 10%) and CoP (relative RMSE approximately 15% for most of the subjects) are accurately predicted over most of the stance phase (from 10% to 90% of stance). However, we found that the foot cannot be very accurately represented by a rollover model just after heel strike (HS) and just before toe off (TO), probably due to shear deformation of foot plantar tissues (ankle motion can occur without any foot rotation). The proposed foot rollover model can be used in both inverse and forward dynamics gait simulation studies and may also find applications in rehabilitation engineering. Copyright 2009 Elsevier Ltd. All rights reserved.

  20. Combined versus individual effects of a valgus knee brace and lateral wedge foot orthotic during stair use in patients with knee osteoarthritis.

    Science.gov (United States)

    Moyer, Rebecca; Birmingham, Trevor; Dombroski, Colin; Walsh, Robert; Giffin, J Robert

    2017-05-01

    The aim of this study was to investigate the combined and individual biomechanical effects of a valgus knee brace and a lateral wedge foot orthotic during stair ascent and descent in patients with knee osteoarthritis (OA). Thirty-five patients with varus alignment and medial knee OA were prescribed a custom valgus knee brace and lateral wedge foot orthotic. Knee angles and moments in the frontal and sagittal planes were determined from 3D gait analysis completed under four randomized conditions: (1) control (no knee brace or foot orthotic), (2) knee brace, (3) foot orthotic, and (4) combined knee brace and foot orthotic. Additional measures included the vertical ground reaction force, trunk lean, toe out and gait speed. During the combined use of a knee brace and foot orthotic, significant decreases in the knee adduction angle (2.17, 95%CI: 0.50-3.84, p=0.013) and 2nd peak EKAM (0.35, 95%CI: 0.17-0.52, pstair descent; and significant increases in the EKFM were observed during stair ascent (0.54, 95%CI: 0.30-0.78, pstair descent compared to ascent, except for toe out. Findings suggest greater effects on gait when both knee brace and foot orthotic are used together, resulting in a more normal gait pattern. However, whether or not a true change in knee joint load can be inferred when using these orthoses remains unclear. Further research is required to determine the clinical importance of the observed changes. Copyright © 2017. Published by Elsevier B.V.

  1. Diagnostic dilemmas in foot and ankle injuries

    Energy Technology Data Exchange (ETDEWEB)

    Keene, J.S.; Lange, R.H.

    1986-07-11

    Differential diagnosis of foot and ankle injuries should include (1) stress fractures of the great toe sesamoids, the shaft of the fifth metatarsal, and the tarsal navicular bone; (2) transchondral talar-dome fractures; (3) fractures of the os trigonum; and (4) dislocating peroneal tendons. Diagnosis of these injuries is challenging because the initial roentgenograms often are normal, and special clinical tests and ancillary studies are required.

  2. Diagnostic dilemmas in foot and ankle injuries

    International Nuclear Information System (INIS)

    Keene, J.S.; Lange, R.H.

    1986-01-01

    Differential diagnosis of foot and ankle injuries should include (1) stress fractures of the great toe sesamoids, the shaft of the fifth metatarsal, and the tarsal navicular bone; (2) transchondral talar-dome fractures; (3) fractures of the os trigonum; and (4) dislocating peroneal tendons. Diagnosis of these injuries is challenging because the initial roentgenograms often are normal, and special clinical tests and ancillary studies are required

  3. A finite element model of the foot and ankle for automotive impact applications.

    Science.gov (United States)

    Shin, Jaeho; Yue, Neng; Untaroiu, Costin D

    2012-12-01

    A finite element (FE) model of the foot and leg was developed to improve understanding of injury mechanisms of the ankle and subtalar joints during vehicle collisions and to aid in the design of injury countermeasures. The FE model was developed based on the reconstructed geometry of a male volunteer close to the anthropometry of a 50th percentile male and a commercial anatomical database. While the forefoot bones were defined as rigid bodies connected by ligament models, the surrounding bones of the ankle and subtalar joints and the leg bones were modeled as deformable structures. The material and structural properties were selected based on a synthesis of current knowledge of the constitutive models for each tissue. The whole foot and leg model was validated in different loading conditions including forefoot impact, axial rotation, dorsiflexion, and combined loadings. Overall results obtained in the model validation indicated improved biofidelity relative to previous FE models. The developed model was used to investigate the injury tolerance of the ankle joint under brake pedal loading for internally and externally rotated feet. Ligament failures were predicted as the main source of injury in this loading condition. A 12% variation of failure moment was observed in the range of axial foot rotations (±15°). The most vulnerable position was the internally rotated (15°) posture among three different foot positions. Furthermore, the present foot and ankle model will be coupled together with other body region FE models into the state-of-art human FE model to be used in the field of automotive safety.

  4. American Orthopaedic Foot and Ankle Society ankle-hindfoot scale: A cross-cultural adaptation and validation study from Iran.

    Science.gov (United States)

    Vosoughi, Amir Reza; Roustaei, Narges; Mahdaviazad, Hamideh

    2017-02-17

    The use of valid and reliable outcome rating scales is essential for evaluating the result of different treatments and interventions. The purposes of this study were to translate and culturally adapt the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale (AOFAS-AHFS) into Persian languages and evaluate its psychometric properties. Forward-backward translation and cultural adaptation method were used to develop Persian version of AOFAS-AHFS. From March to July 2016, one hundred consecutive patients with ankle and hindfoot injuries were included. Internal consistency and reproducibility were evaluated using Cronbach's alpha, Spearman's rank correlation coefficient and Intraclass correlation coefficient (ICC) respectively. Construct validity reported which compare the outcome rating scale measurements with Short Form-36 (SF-36), also convergent and discriminant validity evaluated using Spearman's rank correlation coefficient. Mean age (SD) of the patients was 41.95±13.45years. Cronbach's α coefficient, Spearman's rho and ICC values were 0.71, 0.89 and 0.90 respectively. Total score of AOFAS-AHFS and SF-36 domains has a correlation ranged between 0.17-0.55. Spearman's rank correlation coefficient of 0.4 was exceeded by all items with the exception of stability. The Spearman's rank correlation between each item in functional subscales with its own subscales was higher than the correlation between these items and other subscales. Persian version of AOFAS-AHFS provides additional reliable and valid instrument which can be used to assess broad range of patients with foot and ankle disorders that speaking in Persian. However, it seems that the original version of AOFAS-AHFS needs some revisions. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. Reliability and validity of the foot and ankle outcome score: a validation study from Iran.

    Science.gov (United States)

    Negahban, Hossein; Mazaheri, Masood; Salavati, Mahyar; Sohani, Soheil Mansour; Askari, Marjan; Fanian, Hossein; Parnianpour, Mohamad

    2010-05-01

    The aims of this study were to culturally adapt and validate the Persian version of Foot and Ankle Outcome Score (FAOS) and present data on its psychometric properties for patients with different foot and ankle problems. The Persian version of FAOS was developed after a standard forward-backward translation and cultural adaptation process. The sample included 93 patients with foot and ankle disorders who were asked to complete two questionnaires: FAOS and Short-Form 36 Health Survey (SF-36). To determine test-retest reliability, 60 randomly chosen patients completed the FAOS again 2 to 6 days after the first administration. Test-retest reliability and internal consistency were assessed using intraclass correlation coefficient (ICC) and Cronbach's alpha, respectively. To evaluate convergent and divergent validity of FAOS compared to similar and dissimilar concepts of SF-36, the Spearman's rank correlation was used. Dimensionality was determined by assessing item-subscale correlation corrected for overlap. The results of test-retest reliability show that all the FAOS subscales have a very high ICC, ranging from 0.92 to 0.96. The minimum Cronbach's alpha level of 0.70 was exceeded by most subscales. The Spearman's correlation coefficient for convergent construct validity fell within 0.32 to 0.58 for the main hypotheses presented a priori between FAOS and SF-36 subscales. For dimensionality, the minimum Spearman's correlation coefficient of 0.40 was exceeded by most items. In conclusion, the results of our study show that the Persian version of FAOS seems to be suitable for Iranian patients with various foot and ankle problems especially lateral ankle sprain. Future studies are needed to establish stronger psychometric properties for patients with different foot and ankle problems.

  6. [Treatment of Hallux Valgus: Current Diagnostic Testing and Surgical Treatment Performed by German Foot and Ankle Surgeons].

    Science.gov (United States)

    Arbab, Dariusch; Schneider, Lisa-Maria; Schnurr, Christoph; Bouillon, Bertil; Eysel, Peer; König, Dietmar Pierre

    2018-04-01

    Hallux valgus is one of the most prevalent foot deformities, and surgical treatment of Hallux valgus is one of the most common procedures in foot and ankle surgery. Diagnostic and treatment standards show large variation despite medical guidelines and national foot and ankle societies. The aim of this nationwide survey is a description of the current status of diagnostics and therapy of Hallux valgus in Germany. A nationwide online questionnaire survey was sent to two German foot and ankle societies. The participants were asked to answer a questionnaire of 53 questions with four subgroups (general, diagnostics, operation, preoperative management). Surgical treatment for three clinical cases demonstrating a mild, moderate and severe Hallux valgus deformity was inquired. 427 foot and ankle surgeons answered the questionnaire. 388 participants were certified foot and ankle surgeons from one or both foot and ankle societies. Medical history (78%), preoperative radiographs (100%) and preoperative radiographic management (78%) are of high or very high importance for surgical decision pathway. Outcome scores are used by less than 20% regularly. Open surgery is still the gold standard, whereas minimally invasive surgery is performed by only 7%. Our survey showed that diagnostic standards are met regularly. There is a wide variation in the type of procedures used to treat Hallux valgus deformity. TMT I arthrodesis is preferred in severe Hallux valgus, but also used to treat moderate and mild deformities. Minimally invasive surgery is still used by a minority of surgeons. It remains to be seen, to what extent minimally invasive surgery will be performed in the future. Georg Thieme Verlag KG Stuttgart · New York.

  7. Effects of mid-foot contact area ratio on lower body kinetics/kinematics in sagittal plane during stair descent in women.

    Science.gov (United States)

    Lee, Jinkyu; Hong, Yoon No Gregory; Shin, Choongsoo S

    2016-07-01

    The mid-foot contact area relative to the total foot contact area can facilitate foot arch structure evaluation. A stair descent motion consistently provides initial fore-foot contact and utilizes the foot arch more actively for energy absorption. The purpose of this study was to compare ankle and knee joint angle, moment, and work in sagittal plane during stair descending between low and high Mid-Foot-Contact-Area (MFCA) ratio group. The twenty-two female subjects were tested and classified into two groups (high MFCA and low MFCA) using their static MFCA ratios. The ground reaction force (GRF) and kinematics of ankle and knee joints were measured while stair descending. During the period between initial contact and the first peak in vertical GRF (early absorption phase), ankle negative work for the low MFCA ratio group was 33% higher than that for the high MFCA ratio group (pcontact and peak dorsiflexion angle (early absorption phase+late absorption phase). The peak ankle dorsiflexion angle was smaller in the low MFCA ratio group (p<0.05). Our results suggest that strategy of energy absorption at the ankle and foot differs depending upon foot arch types classified by MFCA. The low MFCA ratio group seemed to absorb more impact energy using strain in the planar fascia during early absorption phase, whereas the high MFCA ratio group absorbed more impact energy using increased dorsiflexion during late absorption phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. The effect of footwear adapted with a multi-curved rocker sole in conjunction with knee-ankle-foot orthoses on walking in poliomyelitis subjects: a pilot study.

    Science.gov (United States)

    Mojaver, Ali; Arazpour, Mokhtar; Aminian, Gholamreza; Ahmadi Bani, Monireh; Bahramizadeh, Mahmood; Sharifi, Guive; Sherafatvaziri, Arash

    2017-10-01

    Knee-ankle-foot orthoses (KAFOs) are used by people with poliomyelitis to ambulate. Whist advances in orthotic knee joint designs for use in KAFOs such the provision of stance control capability have proven efficacy, little attention has been paid to shoe adaptations which may also improve gait. The aim of this study was to evaluate the alteration to the kinematics and temporal-spatial parameters of gait caused by the use of heel-to-toe rocker-soled footwear when ambulating with KAFOs. Nine adults with a history of poliomyelitis who routinely wore KAFOs participated in the study. A heel-to-toe rocker sole was added to footwear and worn on the affected side. A three-dimensional motion capture system was used to quantify the resulting alteration to specific gait parameters. Maximum hip joint extension was significantly increased (p = 0.011), and hip abduction and adduction were both significantly reduced (p = 0.011 and p = 0.007, respectively) when walking with the rocker sole. A significant increase in stride length (p = 0.035) was demonstrated but there were no significant increases in either walking speed or cadence. A heel-to-toe rocker sole adaptation may be useful for walking in patients with poliomyelitis who use KAFOs. Implications for Rehabilitation The poor functionality and difficulty in walking when using an orthotic device such as a KAFO which keeps the knee locked during ambulation, plus the significant energy required to walk, are complications of orthoses using. Little evidence exists regarding the biomechanical effect of walking with a KAFO incorporating fixed knee joints, in conjunction with rocker-soled footwear. The main aim of walking with a heel-to-toe rocker sole is to facilitate forward progression of the tibia when used with an AFO or KAFO or to provide easier walking for patients who have undergone an ankle arthrodesis. In this study, a rocker sole profile adaptation produced no significant alteration to hip joint flexion

  9. Foot and Ankle Deformity in Young Acrobatic and Artistic Gymnasts

    Directory of Open Access Journals (Sweden)

    Sobera Anna

    2015-09-01

    Full Text Available Purpose. The aim of the paper was to determine the occurrence of feet and ankle deformities in trampoline and artistic gymnasts. Methods. Ten acrobatic gymnasts (trampolinists and 10 artistic gymnasts aged 6-14 years were recruited. The calcaneal-tibial (rearfoot angle was determined as the angle of the upper calcaneal tendon and the longitudinal heel axis while Clarke angles were determined by podoscopy. Results. The trampolinists showed significantly greater medial angulation (calcaneal valgus than the group of gymnasts. Right and left foot Clark’s angles in both the trampoline and artistic gymnasts were above 55°. Conclusions. Trampolinists exhibit significantly more pronounced calcaneal valgus than artistic gymnasts. The prevalence of foot and ankle deformities in both populations should be addressed by coaches in the gymnastics training of young children.

  10. The American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale; translation and validation of the Dutch language version for ankle fractures.

    Science.gov (United States)

    de Boer, A Siebe; Tjioe, Roderik J C; Van der Sijde, Fleur; Meuffels, Duncan E; den Hoed, Pieter T; Van der Vlies, Cornelis H; Tuinebreijer, Wim E; Verhofstad, Michael H J; Van Lieshout, Esther M M

    2017-08-03

    The American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale is among the most commonly used instruments for measuring outcome of treatment in patients who sustained a complex ankle or hindfoot injury. It consists of a patient-reported and a physician-reported part. A validated, Dutch version of this instrument is currently not available. The aim of this study was to translate the instrument into Dutch and to determine the measurement properties of the AOFAS Ankle-Hindfoot Scale Dutch language version (DLV) in patients with a unilateral ankle fracture. Multicentre (two Dutch hospitals), prospective observational study. In total, 142 patients with a unilateral ankle fracture were included. Ten patients were lost to follow-up. Patients completed the subjective (patient-reported) part of the AOFAS Ankle-Hindfoot Scale-DLV. A physician or trained physician-assistant completed the physician-reported part. For comparison and evaluation of the measuring characteristics, the Foot Function Index and the Short Form-36 were completed by the patient. Descriptive statistics (including floor and ceiling effects), reliability (ie, internal consistency), construct validity, reproducibility (ie, test-retest reliability, agreement and smallest detectable change) and responsiveness were determined. The AOFAS-DLV and its subscales showed good internal consistency (Cronbach's α >0.90). Construct validity and longitudinal validity were proven to be adequate (76.5% of predefined hypotheses were confirmed). Floor effects were not present. Ceiling effects were present from 6 months onwards, as expected. Responsiveness was adequate, with a smallest detectable change of 12.0 points. The AOFAS-DLV is a reliable, valid and responsive measurement instrument for evaluating functional outcome in patients with a unilateral ankle fracture. This implies that the questionnaire is suitable to compare different treatment modalities within this population or to compare outcome across

  11. Beyond the Bottom of the Foot: Topographic Organization of the Foot Dorsum in Walking.

    Science.gov (United States)

    Klarner, Taryn; Pearcey, Gregory E P; Sun, Yao; Barss, Trevor S; Kaupp, Chelsea; Munro, Bridget; Frank, Nick; Zehr, E Paul

    2017-12-01

    Sensory feedback from the foot dorsum during walking has only been studied globally by whole nerve stimulation. Stimulating the main nerve innervating the dorsal surface produces a functional stumble corrective response that is phase-dependently modulated. We speculated that effects evoked by activation of discrete skin regions on the foot dorsum would be topographically organized, as with the foot sole. Nonnoxious electrical stimulation was delivered to five discrete locations on the dorsal surface of the foot during treadmill walking. Muscle activity from muscles acting at the ankle, knee, hip, and shoulder were recorded along with ankle, knee, and hip kinematics and kinetic information from forces under the foot. All data were sorted on the basis of stimulus occurrence in 12 step cycle phases, before being averaged together within a phase for subsequent analysis. Results reveal dynamic changes in reflex amplitudes and kinematics that are site specific and phase dependent. Most responses from discrete sites on the foot dorsum were seen in the swing phase suggesting function to conform foot trajectory to maintain stability of the moving limb. In general, responses from lateral stimulation differed from medial stimulation, and effects were largest from stimulation at the distal end of the foot at the metatarsals; that is, in anatomical locations where actual impact with an object in the environment is most likely during swing. Responses to stimulation extend to include muscles at the hip and shoulder. We reveal that afferent feedback from specific cutaneous locations on the foot dorsum influences stance and swing phase corrective responses. This emphasizes the critical importance of feedback from the entire foot surface in locomotor control and has application for rehabilitation after neurological injury and in footwear development.

  12. Effects of barefoot and barefoot inspired footwear on knee and ankle loading during running.

    Science.gov (United States)

    Sinclair, Jonathan

    2014-04-01

    Recreational runners frequently suffer from chronic pathologies. The knee and ankle have been highlighted as common injury sites. Barefoot and barefoot inspired footwear have been cited as treatment modalities for running injuries as opposed to more conventional running shoes. This investigation examined knee and ankle loading in barefoot and barefoot inspired footwear in relation to conventional running shoes. Thirty recreational male runners underwent 3D running analysis at 4.0m·s(-1). Joint moments, patellofemoral contact force and pressure and Achilles tendon forces were compared between footwear. At the knee the results show that barefoot and barefoot inspired footwear were associated with significant reductions in patellofemoral kinetic parameters. The ankle kinetics indicate that barefoot and barefoot inspired footwear were associated with significant increases in Achilles tendon force compared to conventional shoes. Barefoot and barefoot inspired footwear may serve to reduce the incidence of knee injuries in runners although corresponding increases in Achilles tendon loading may induce an injury risk at this tendon. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Biomechanical Differences of Foot-Strike Patterns During Running: A Systematic Review With Meta-analysis.

    Science.gov (United States)

    Almeida, Matheus O; Davis, Irene S; Lopes, Alexandre D

    2015-10-01

    Systematic review with meta-analysis. To determine the biomechanical differences between foot-strike patterns used when running. Strike patterns during running have received attention in the recent literature due to their potential mechanical differences and associated injury risks. Electronic databases (MEDLINE, Embase, LILACS, SciELO, and SPORTDiscus) were searched through July 2014. Studies (cross-sectional, case-control, prospective, and retrospective) comparing the biomechanical characteristics of foot-strike patterns during running in distance runners at least 18 years of age were included in this review. Two independent reviewers evaluated the risk of bias. A meta-analysis with a random-effects model was used to combine the data from the included studies. Sixteen studies were included in the final analysis. In the meta-analyses of kinematic variables, significant differences between forefoot and rearfoot strikers were found for foot and knee angle at initial contact and knee flexion range of motion. A forefoot-strike pattern resulted in a plantar-flexed ankle position and a more flexed knee position, compared to a dorsiflexed ankle position and a more extended knee position for the rearfoot strikers, at initial contact with the ground. In the comparison of rearfoot and midfoot strikers, midfoot strikers demonstrated greater ankle dorsiflexion range of motion and decreased knee flexion range of motion compared to rearfoot strikers. For kinetic variables, the meta-analysis revealed that rearfoot strikers had higher vertical loading rates compared to forefoot strikers. There are differences in kinematic and kinetic characteristics between foot-strike patterns when running. Clinicians should be aware of these characteristics to help in the management of running injuries and advice on training.

  14. Journal of Foot and Ankle Research, one year on

    Directory of Open Access Journals (Sweden)

    Borthwick Alan M

    2009-11-01

    Full Text Available Abstract Journal of Foot and Ankle Research was launched one year ago, and a number of its key achievements are highlighted in this editorial. Although the journal is underpinned by professional bodies associated with the podiatry professions in the UK and Australasia, its content is aimed at the wider foot and ankle research community. Nevertheless, the journal's achievements over the past year reflect the development of research in the profession of podiatry. From this perspective, the journal may be viewed as contributing to the overall attainment of some of the profession's key goals and strategic aims over the last decade, across the UK and Australasia. The journal has also witnessed policy changes in the last year, and these are discussed - notably, the decision not to accept case reports for publication. We also report on a few of the key metrics, providing readers with a summary of the journal's performance over the last year.

  15. Managing dislocations of the hip, knee, and ankle in the emergency department [digest].

    Science.gov (United States)

    Arnold, Caylyne; Fayos, Zane; Bruner, David; Arnold, Dylan; Gupta, Nachi; Nusbaum, Jeffrey

    2017-12-20

    Dislocation of the major joints of the lower extremities--hip, knee, and ankle--can occur due to motor-vehicle crashes, falls, and sports injuries. Hip dislocations are the most common, and they require emergent management to prevent avascular necrosis of the femoral head. Knee dislocations are uncommon but potentially dangerous injuries that can result in amputation due to the potential for missed secondary injury, especially if they are reduced spontaneously. Isolated ankle dislocations are relatively rare, as most ankle dislocations involve an associated fracture. This review presents an algorithmic approach to management that ensures that pain relief, imaging, reduction, vascular monitoring, and emergent orthopedic consultation are carried out in a timely fashion. [Points & Pearls is a digest of Emergency Medicine Practice.].

  16. Factors Influencing Patient Selection of a Foot and Ankle Surgeon.

    Science.gov (United States)

    Manning, Blaine T; Bohl, Daniel D; Wang, Kevin C; Hamid, Kamran S; Holmes, George B; Lee, Simon

    2017-09-01

    An increasingly consumer-centric health insurance market has empowered patients to select the providers of their choice. There is a lack of studies investigating the rationale by which patients select a foot and ankle surgeon. In the present study, 824 consecutive new patients seeking treatment from 3 foot-ankle surgeons were consecutively administered an anonymous questionnaire prior to their first appointment. It included rating the importance of 15 factors regarding specialist selection on a 1 to 10 scale, with 10 designated " Very important" and 1 designated " Not important at all." The remaining questions were multiple choice regarding patient perspectives on other surgeon aspects (appointment availability, waiting room times, clinic proximity, etc). Of 824 consecutive patients administered the survey, 305 (37%) responded. Patients rated board certification (9.24 ± 1.87) and on-site imaging availability (8.48 ± 2.37)-on a 1 to 10 scale, with 10 designated "Very important- as the 2 most important criteria in choosing a foot and ankle surgeon. Patients rated advertisements as least important. Among the patients, 91% responded that a maximum of 30 minutes should elapse between clinic check-in and seeing their physician; 61% responded that a maximum of 20 minutes should elapse between clinic check-in and seeing their physician. In the context of an increasingly consumer-driven paradigm of health care delivery and reimbursement, it is important to understand patients' preferences in specialist selection. Level III: Prospective questionnaire.

  17. A new RF transmit coil for foot and ankle imaging at 7T MRI.

    Science.gov (United States)

    Santini, Tales; Kim, Junghwan; Wood, Sossena; Krishnamurthy, Narayanan; Farhat, Nadim; Maciel, Carlos; Raval, Shailesh B; Zhao, Tiejun; Ibrahim, Tamer S

    2018-01-01

    A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B 1 + field distribution and s-parameters. Simulations performed on an anatomically detailed human lower leg model demonstrated an B 1 + field distribution with a coefficient of variation (CV) of 23.9%/15.6%/28.8% and average B 1 + of 0.33μT/0.56μT/0.43μT for 1W input power (i.e., 0.25W per channel) in the ankle/calcaneus/mid foot respectively. In-vivo B 1 + mapping shows an average B 1 + of 0.29μT over the entire foot/ankle. This newly developed RF coil also presents acceptable levels of average SAR (0.07W/kg for 10g per 1W of input power) and peak SAR (0.34W/kg for 10g per 1W of input power) over the whole lower leg. Preliminary in-vivo images in the foot/ankle were acquired using the T2-DESS MRI sequence without the use of a dedicated receive-only array. Copyright © 2017. Published by Elsevier Inc.

  18. A cross-sectional observational study comparing foot and ankle characteristics in people with stroke and healthy controls

    OpenAIRE

    Kunkel, Dorit; Potter, Julia; Mamode, Louis

    2016-01-01

    Purpose: The purpose of this study was to explore and compare foot and ankle characteristics in people with stroke and healthy controls; and between stroke fallers and non-fallers.Methods: Participants were recruited from community groups and completed standardized tests assessing sensation, foot posture, foot function, ankle dorsiflexion and first metatarsal phalangeal joint range of motion (1st MPJ ROM), hallux valgus presence and severity.Results: Twenty-three stroke participants (mean age...

  19. Natural history of sensory nerve recovery after cutaneous nerve injury following foot and ankle surgery

    Directory of Open Access Journals (Sweden)

    Lu Bai

    2015-01-01

    Full Text Available Cutaneous nerve injury is the most common complication following foot and ankle surgery. However, clinical studies including long-term follow-up data after cutaneous nerve injury of the foot and ankle are lacking. In the current retrospective study, we analyzed the clinical data of 279 patients who underwent foot and ankle surgery. Subjects who suffered from apparent paresthesia in the cutaneous sensory nerve area after surgery were included in the study. Patients received oral vitamin B 12 and methylcobalamin. We examined final follow-up data of 17 patients, including seven with sural nerve injury, five with superficial peroneal nerve injury, and five with plantar medial cutaneous nerve injury. We assessed nerve sensory function using the Medical Research Council Scale. Follow-up immediately, at 6 weeks, 3, 6 and 9 months, and 1 year after surgery demonstrated that sensory function was gradually restored in most patients within 6 months. However, recovery was slow at 9 months. There was no significant difference in sensory function between 9 months and 1 year after surgery. Painful neuromas occurred in four patients at 9 months to 1 year. The results demonstrated that the recovery of sensory function in patients with various cutaneous nerve injuries after foot and ankle surgery required at least 6 months

  20. Measurement properties of the most commonly used Foot- and Ankle-Specific Questionnaires: the FFI, FAOS and FAAM. A systematic review.

    Science.gov (United States)

    Sierevelt, I N; Zwiers, R; Schats, W; Haverkamp, D; Terwee, C B; Nolte, P A; Kerkhoffs, G M M J

    2017-10-12

    In the foot and ankle literature, a wide range of patient-reported outcome measures (PROMs) is used, however, consensus as to which PROMs are preferred is lacking. Selection of a PROM is among other reasons, often based on measurement properties without considering the methodological quality of the studies that evaluate these measurement properties. The aim of current study was first to identify the most frequently used foot and ankle-specific PROMs in recent orthopaedic foot and ankle literature, and second to conduct a systematic review to synthesize and critically appraise the measurement properties of these PROMS. Six PubMed indexed journals focussing on foot and ankle research were screened to identify most commonly used foot and ankle-specific PROMs over a 2 year period (2015-2016). Subsequently, a systematic literature search was performed in PubMed, EMBASE, SPORTDiscus and Scopus to identify relevant studies on their measurement properties. Methodological quality assessment was performed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist, criteria for good measurement properties were applied, and a level of evidence was determined for the measurement properties of each domain of the questionnaires. The three most frequently reported PROMs were the Foot Function Index (FFI), the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Activity Measure (FAAM). Among 2046 unique citations, 50 studies were included evaluating these PROMs. Evidence to support the measurement properties of the FFI was mainly lacking due to poor methodological quality. More evidence was available for the measurement properties of the FAOS and the FAAM, but overall evidence supporting all measurement properties is not yet sufficient. The best available evidence retrieved in this review showed that the FAOS and the FAAM are promising outcome measures for evaluation of patients with foot and ankle conditions, but their

  1. Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.

    Science.gov (United States)

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren; Cook, Chad

    2013-08-01

    Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. 3a.

  2. Spring-like Ankle Foot Orthoses reduce the energy cost of walking by taking over ankle work.

    Science.gov (United States)

    Bregman, D J J; Harlaar, J; Meskers, C G M; de Groot, V

    2012-01-01

    In patients with central neurological disorders, gait is often limited by a reduced ability to push off with the ankle. To overcome this reduced ankle push-off, energy-storing, spring-like carbon-composite Ankle Foot Orthoses (AFO) can be prescribed. It is expected that the energy returned by the AFO in late stance will support ankle push-off, and reduce the energy cost of walking. In 10 patients with multiple sclerosis and stroke the energy cost of walking, 3D kinematics, joint power, and joint work were measured during gait, with and without the AFO. The mechanical characteristics of the AFO were measured separately, and used to calculate the contribution of the AFO to the ankle kinetics. We found a significant decrease of 9.8% in energy cost of walking when walking with the AFO. With the AFO, the range of motion of the ankle was reduced by 12.3°, and the net work around the ankle was reduced by 29%. The total net work in the affected leg remained unchanged. The AFO accounted for 60% of the positive ankle work, which reduced the total amount of work performed by the leg by 11.1% when walking with the AFO. The decrease in energy cost when walking with a spring-like energy-storing AFO in central neurological patients is not induced by an augmented net ankle push-off, but by the AFO partially taking over ankle work. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Ankle mechanics during sidestep cutting implicates need for 2-degrees of freedom powered ankle-foot prostheses.

    Science.gov (United States)

    Ficanha, Evandro M; Rastgaar, Mohammad; Kaufman, Kenton R

    2015-01-01

    The ankle joint of currently available powered prostheses is capable of controlling one degree of freedom (DOF), focusing on improved mobility in the sagittal plane. To increase agility, the requirements of turning in prosthesis design need to be considered. Ankle kinematics and kinetics were studied during sidestep cutting and straight walking. There were no significant differences between the ankle sagittal plane mechanics when comparing sidestep cutting and straight walking; however, significant differences were observed in ankle frontal plane mechanics. During straight walking, the inversion-eversion (IE) angles were smaller than with sidestep cutting. The ankle that initiated the sidestep cutting showed progressively increasing inversion from 2 to 13 degrees while the following contralateral step showed progressively decreasing inversion from 8 to -4 degrees during normal walking speed. The changes in IE kinematics were the most significant during sidestep cutting compared with straight walking. The IE moments of the step that initiated the sidestep cutting were always in eversion, acting as a braking moment opposing the inverting motion. This suggests that an ankle-foot prosthesis with active DOFs in the sagittal and frontal planes will increase the agility of gait for patients with limb loss.

  4. ANALYSIS OF ANKLE ALIGNMENT ABNORMALITIES AS A RISK FACTOR FOR PEDIATRIC FLEXIBLE FLAT FOOT

    Directory of Open Access Journals (Sweden)

    Dr. Ajai Singh

    2010-01-01

    Full Text Available Majority of paediatric flat feet are flexible and asymptomatic; less than 0.1% of all flat feet are rigid. If these can be diagnosed and managed early, then various complications can be prevented and they will remain asymptomatic. This study was conducted to analyse the ankle rotational mal-alignments in the natural course of flexible flat foot in children. Seventy-six patients of flexible flat foot and one hundred controls were included in this study. The height of foot arches was judged clinically by inspecting the height of the medial arch and by measuring the arch index on weight-bearing podograms. Tibial torsion and bimalleolar angle were assessed in all subjects. Tibial torsion was assessed in the first twenty subjects (ten cases and ten controls both by clinical methods (foot-thigh angle and CT. As no statistical difference in the two methods was observed, tibial torsion was measured by clinical methods only in the remaining subjects. Bimalleolar angle was measured on weight-bearing podograms in all subjects. For a minimum of two years, cases were followed up regularly with a standard conservative protocol and the height of the arches observed. Majority of cases of flexible flat foot were found to have increased tibial torsion and increased foot-bimalleolar angle (high talar spin. The severity of collapse of the medial arch and the response to conservative treatment was found to correlate with these rotational mal-alignments of the ankle. Ankle rotational mal-alignments were seen to make these flexible flat foot deformities more complex and less responsive to conservative treatment.

  5. Validation of the Dutch language version of the Foot and Ankle Outcome Score.

    Science.gov (United States)

    Sierevelt, I N; Beimers, L; van Bergen, C J A; Haverkamp, D; Terwee, C B; Kerkhoffs, G M M J

    2015-08-01

    The aim of this study was to develop a Dutch language version of the Foot and Ankle Outcome Score (FAOS-DLV) and evaluate its measurement properties according to the definitions of the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). After a standard forward-backward translation procedure, the Dutch version of the FAOS was evaluated for reliability and validity in 110 patients with various hind foot and ankle complaints. Reliability was evaluated by calculation of intraclass correlation coefficients (ICC), Cronbach's alpha for internal consistency, and the smallest detectable change (SDC). Construct validity of the FAOS was assessed by calculation of Spearman's correlation coefficients with similar and dissimilar domains of the SF-36 health survey, American Orthopedic Foot and Ankle Society Ankle and Hindfoot Scale, and visual analogue scales for pain and disability. Dimensionality was tested with confirmatory factor analysis. Reliability of the FAOS-DLV was good. The ICC of the subscales ranged from 0.83 to 0.88. The minimal value of Cronbach's alpha was 0.76. The SDC at individual level ranged from 18 to 21 and at group level between 2.1 and 2.5. Construct validity was supported by confirmation of 85 % of the hypothesized correlations. Unidimensionality of the FAOS-DLV domains was moderate. The Dutch version of the FAOS seems to have acceptable measurement properties. The questionnaire can be used for functional assessment of patients with varying hindfoot and ankle symptoms. It is, however, more suitable for clinical evaluation at group level than for monitoring a specific patient. Diagnostic study, Level I.

  6. Defining the mechanical properties of a spring-hinged ankle foot orthosis to assess its potential use in children with spastic cerebral palsy.

    Science.gov (United States)

    Kerkum, Yvette L; Brehm, Merel-Anne; Buizer, Annemieke I; van den Noort, Josien C; Becher, Jules G; Harlaar, Jaap

    2014-12-01

    A rigid ventral shelf ankle foot orthosis (AFO) may improve gait in children with spastic cerebral palsy (SCP) whose gait is characterized by excessive knee flexion in stance. However, these AFOs can also impede ankle range of motion (ROM) and thereby inhibit push-off power. A more spring-like AFO can enhance push-off and may potentially reduce walking energy cost. The recent development of an adjustable spring-hinged AFO now allows adjustment of AFO stiffness, enabling tuning toward optimal gait performance. This study aims to quantify the mechanical properties of this spring-hinged AFO for each of its springs and settings. Using an AFO stiffness tester, two AFO hinges and their accompanying springs were measured. The springs showed a stiffness range of 0.01-1.82 N · m · deg(-1). The moment-threshold increased with increasing stiffness (1.13-12.1 N · m), while ROM decreased (4.91-16.5°). Energy was returned by all springs (11.5-116.3 J). These results suggest that the two stiffest available springs should improve joint kinematics and enhance push-off in children with SCP walking with excessive knee flexion.

  7. Once-per-step control of ankle-foot prosthesis push-off work reduces effort associated with balance during walking.

    Science.gov (United States)

    Kim, Myunghee; Collins, Steven H

    2015-05-01

    Individuals with below-knee amputation have more difficulty balancing during walking, yet few studies have explored balance enhancement through active prosthesis control. We previously used a dynamical model to show that prosthetic ankle push-off work affects both sagittal and frontal plane dynamics, and that appropriate step-by-step control of push-off work can improve stability. We hypothesized that this approach could be applied to a robotic prosthesis to partially fulfill the active balance requirements of human walking, thereby reducing balance-related activity and associated effort for the person using the device. We conducted experiments on human participants (N = 10) with simulated amputation. Prosthetic ankle push-off work was varied on each step in ways expected to either stabilize, destabilize or have no effect on balance. Average ankle push-off work, known to affect effort, was kept constant across conditions. Stabilizing controllers commanded more push-off work on steps when the mediolateral velocity of the center of mass was lower than usual at the moment of contralateral heel strike. Destabilizing controllers enforced the opposite relationship, while a neutral controller maintained constant push-off work regardless of body state. A random disturbance to landing foot angle and a cognitive distraction task were applied, further challenging participants' balance. We measured metabolic rate, foot placement kinematics, center of pressure kinematics, distraction task performance, and user preference in each condition. We expected the stabilizing controller to reduce active control of balance and balance-related effort for the user, improving user preference. The best stabilizing controller lowered metabolic rate by 5.5% (p = 0.003) and 8.5% (p = 0.02), and step width variability by 10.0% (p = 0.009) and 10.7% (p = 0.03) compared to conditions with no control and destabilizing control, respectively. Participants tended to prefer stabilizing controllers

  8. Proximal Tibia Bone Graft: An alternative Donor Source especially for Foot and Ankle Procedures

    Directory of Open Access Journals (Sweden)

    Jia TY

    2015-03-01

    Full Text Available Among the many donor sites for harvesting autologous bone graft, the iliac crest has been the most commonly used. However, for foot and ankle procedures the proximal tibia has gained popularity as an alternative donor site due to its anatomic proximity to the primary surgical site. In this article we evaluated the possible complications associated with harvesting proximal tibia bone graft. Our study showed the low incidence of morbidity in harvesting proximal tibia bone graft, thereby providing a good alternative donor for foot and ankle procedures.

  9. Lawn mower injuries of the pediatric foot and ankle: observations on prevention and management.

    Science.gov (United States)

    Vosburgh, C L; Gruel, C R; Herndon, W A; Sullivan, J A

    1995-01-01

    We reviewed 32 children with lower extremity injuries caused by power lawn mowers. Functional outcome of 21 patients was evaluated. Anatomical injury patterns provide some guidelines in management and prediction of functional outcome. Consistently, the most severe injuries result from ride-on mowers and wounds to the posterior/plantar foot and ankle. Our experience with pediatric foot and ankle lawn mower injuries permits recommendations for maximum functional outcome with minimal intervention. Public awareness and mower safety devices may be required to decrease the rate of accidents in the future.

  10. Long-term stress distribution patterns of the ankle joint in varus knee alignment assessed by computed tomography osteoabsorptiometry.

    Science.gov (United States)

    Onodera, Tomohiro; Majima, Tokifumi; Iwasaki, Norimasa; Kamishima, Tamotsu; Kasahara, Yasuhiko; Minami, Akio

    2012-09-01

    The stress distribution of an ankle under various physiological conditions is important for long-term survival of total ankle arthroplasty. The aim of this study was to measure subchondral bone density across the distal tibial joint surface in patients with malalignment/instability of the lower limb. We evaluated subchondral bone density across the distal tibial joint in patients with malalignment/instability of the knee by computed tomography (CT) osteoabsorptiometry from ten ankles as controls and from 27 ankles with varus deformity/instability of the knee. The quantitative analysis focused on the location of the high-density area at the articular surface, to determine the resultant long-term stress on the ankle joint. The area of maximum density of subchondral bone was located in the medial part in all subjects. The pattern of maximum density in the anterolateral area showed stepwise increases with the development of varus deformity/instability of the knee. Our results should prove helpful for designing new prostheses and determining clinical indications for total ankle arthroplasty.

  11. Responses of spinal dorsal horn neurons to foot movements in rats with a sprained ankle

    OpenAIRE

    Kim, Jae Hyo; Kim, Hee Young; Chung, Kyungsoon; Chung, Jin Mo

    2011-01-01

    Acute ankle injuries are common problems and often lead to persistent pain. To investigate the underlying mechanism of ankle sprain pain, the response properties of spinal dorsal horn neurons were examined after ankle sprain. Acute ankle sprain was induced manually by overextending the ankle of a rat hindlimb in a direction of plantarflexion and inversion. The weight-bearing ratio (WBR) of the affected foot was used as an indicator of pain. Single unit activities of dorsal horn neurons in res...

  12. Bilateral knee and right ankle osteonecrosis in an adolescent girl with acute lymphoblastic leukemia

    Directory of Open Access Journals (Sweden)

    Ülker Koçak

    2009-03-01

    Full Text Available Although rare, avascular necrosis of bone is a serious and incapacitating complication seen in children with acute lymphoblastic leukemia receiving high dose steroids. Here we present a 16 year-old girl who developed bilateral knee and right ankle avascular osteonecrosis one year after intensive chemotherapy for medium risk acute lymphoblastic leukemia. Indirect curettage of necrotic tissue and bone grafting were performed for both knees whereas conservative measures had been sufficient for the ankle. Early recognition of this condition is important in prevention of disabling sequela in skeletal system.

  13. Swing limb mechanics and minimum toe clearance in people with knee osteoarthritis.

    Science.gov (United States)

    Levinger, Pazit; Lai, Daniel T H; Menz, Hylton B; Morrow, Adam D; Feller, Julian A; Bartlett, John R; Bergman, Neil R; Begg, Rezaul

    2012-02-01

    Knee osteoarthritis (OA) has been shown to be a risk factor for falls. Reductions in foot clearance during the swing phase of walking can cause a trip and potentially lead to a fall. This study examined the swing phase mechanics of people with and without knee OA during walking. Minimum toe clearance (MTC) height, joint angles at the time of MTC and the influence of the angular changes of the hip, knee and ankle of the swing leg on foot clearance using sensitivity analysis were investigated in 50 knee OA participants and 28 age-matched asymptomatic controls. Although both groups had a similar MTC height (controls: 12.8±6.7 mm, knee OA: 13.4±7.0 mm), the knee OA group used a different strategy to achieve the same foot clearance, as evidenced by greater knee flexion (52.5±5.3° vs 49.4±4.8°, p=0.007), greater hip abduction (-3.6±3.3° vs -1.8±3.3°, p=0.03) and less ankle adduction (2.8±1.9° vs 4.2±2.1°, p=0.01). MTC height was comparable between the groups, however a different swing phase mechanism was used by the knee OA. Although adequate MTC is an important component of safe locomotion, it does not appear to be impaired in people with knee OA. Other factors, such as inadequate responses to postural perturbation, may be responsible for falls in this group. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. The effect of ankle foot orthosis stiffness on the energy cost of walking : A simulation study

    NARCIS (Netherlands)

    Bregman, D.J.J.; Van der Krogt, M.M.; De Groot, V.; Harlaar, J.; Wisse, M.; Collins, S.H.

    2011-01-01

    Background In stroke and multiple sclerosis patients, gait is frequently hampered by a reduced ability to push-off with the ankle caused by weakness of the plantar-flexor muscles. To enhance ankle push-off and to decrease the high energy cost of walking, spring-like carbon-composite Ankle Foot

  15. The effect of ankle foot orthosis stiffness on the energy cost of walking: A simulation study.

    NARCIS (Netherlands)

    Bregman, D.J.J.; van der Krogt, M.M.; de Groot, V.; Harlaar, J.; Wisse, M.; Collins, S.H.

    2011-01-01

    Background: In stroke and multiple sclerosis patients, gait is frequently hampered by a reduced ability to push-off with the ankle caused by weakness of the plantar-flexor muscles. To enhance ankle push-off and to decrease the high energy cost of walking, spring-like carbon-composite Ankle Foot

  16. COMPARISON OF GAIT USING A MULTIFLEX FOOT VERSUS A QUANTUM FOOT IN KNEE DISARTICULATION AMPUTEES

    NARCIS (Netherlands)

    BOONSTRA, AM; FIDLER, [No Value; SPITS, GMA; HOF, AL; Tuil, P.

    The subjective responses and gait patterns of unilateral knee disarticulation amputees wearing prostheses fitted first with the Multiflex foot and then with the Quantum foot were studied. Nine amputees were included in the trial. A questionnaire asked the amputees about their preference for one of

  17. A one year prospective study on ankle stability and landing technique : The occurrence of ankle and knee injuries in elite ball team athletes

    NARCIS (Netherlands)

    Msc Henrike van der Does; M.S. Brink; Koen A.P.M. Lemmink

    2014-01-01

    Background: In team sports lower extremity injuries account for more than 50% of all injuries, indicating the importance of early detection of athletes at risk. Objective: To investigate the predictive value of ankle stability and landing technique at baseline for ankle and knee injury occurrence

  18. Definition of coordinate system for three-dimensional data analysis in the foot and ankle.

    LENUS (Irish Health Repository)

    Green, Connor

    2012-02-01

    BACKGROUND: Three-dimensional data is required to have advanced knowledge of foot and ankle kinematics and morphology. However, studies have been difficult to compare due to a lack of a common coordinate system. Therefore, we present a means to define a coordinate frame in the foot and ankle and its clinical application. MATERIALS AND METHODS: We carried out ten CT scans in anatomically normal feet and segmented them in a general purpose segmentation program for grey value images. 3D binary formatted stereolithography files were then create and imported to a shape analysis program for biomechanics which was used to define a coordinate frame and carry out morphological analysis of the forefoot. RESULTS: The coordinate frame had axes standard deviations of 2.36 which are comparable to axes variability of other joint coordinate systems. We showed a strong correlation between the lengths of the metatarsals within and between the columns of the foot and also among the lesser metatarsal lengths. CONCLUSION: We present a reproducible method for construction of a coordinate system for the foot and ankle with low axes variability. CLINICAL RELEVANCE: To conduct meaningful comparison between multiple subjects the coordinate system must be constant. This system enables such comparison and therefore will aid morphological data collection and improve preoperative planning accuracy.

  19. Management strategies of sarcomas of the ankle and foot

    International Nuclear Information System (INIS)

    Douglas, R.M.; Mankin, H.J.; Jennings, L.C.; Gebhardt, M.C.; Harmon, D.; Ancukiewicz, M.; Suit, H.D.; Spiro, Ira J.

    1997-01-01

    Purpose: To evaluate the management and outcomes of 40 patients treated at the Massachusetts General Hospital between 1974 and September 1996 for soft tissue sarcomas of the foot or ankle. Materials and Methods: Seventy seven percent of patients had AJCC stage II or III disease. Primary disease was treated in 28 patients while recurrent disease was addressed in 12. The mean tumor size was 4.6 cm with a median tumor size of 4.0 cm, (range 1 to 15 cm). Seventeen patients were treated with surgery followed by radiation therapy for primary or recurrent disease. Preoperative radiation therapy was employed in 15 patients, 5 of whom received additional postoperative radiation therapy for close or positive margins. Six patients received radiation treatment alone. Amputations were performed in 5 patients. Two amputations were performed due to inadequate surgical margins obtained at the time of resection. Three amputations were performed due to local failure. The median preoperative radiation dose was 48 Gy. The median total dose was 59 Gy (range 22 Gy to 70 Gy). Chemotherapy was incorporated in the therapy of 6 patients. Results: After a mean follow-up of 4.9 years, 28 (70%) patients remain without evidence of disease. Four patients have died of disease. Five patients have died of intercurrent disease or another cancer. Three patients remain alive with disease. There were 5 isolated local failures, 4 distant failures and 1 combined local and distant failure. Of the 5 patients with isolated local failures, 3 were treated with radiation alone. The most common site of distant failure was the lung. Actuarial local control rates are 80% at 5 and 10 years in this population. Actuarial overall survival at 5 and 10 years are 83% and 69% respectively. Wound healing difficulties occurred in 13 patients. Seven patients suffered a wound dehiscence. Five patients required therapy for wound dehiscence and infection and one patient was treated for wound infection only. In six patients

  20. Bone grafting in surgery about the foot and ankle: indications and techniques.

    Science.gov (United States)

    Fitzgibbons, Timothy C; Hawks, Michael A; McMullen, Scott T; Inda, David J

    2011-02-01

    Bone grafting is a common procedure in foot and ankle surgery. Historically, autogenous bone graft has most often been harvested from the ipsilateral iliac crest. However, other sites offer similar volumes of cancellous bone and are associated with fewer complications. The ipsilateral proximal tibia, distal tibia, and calcaneus provide adequate amounts of bone graft material for most arthrodesis procedures about the foot and ankle. Emerging techniques have enabled the development of a seemingly unlimited supply of alternative bone graft materials with osteoconductive properties. The osteoprogenitor cells in bone marrow aspirates can be concentrated by use of selective retention systems. These aspirate-matrix composites may be combined with allograft preparations, resulting in a product that promotes osteoconduction, osteoinduction, and osteogenesis with limited morbidity.

  1. A cross-sectional observational study comparing foot and ankle characteristics in people with stroke and healthy controls.

    Science.gov (United States)

    Kunkel, Dorit; Potter, Julia; Mamode, Louis

    2017-06-01

    The purpose of this study was to explore and compare foot and ankle characteristics in people with stroke and healthy controls; and between stroke fallers and non-fallers. Participants were recruited from community groups and completed standardized tests assessing sensation, foot posture, foot function, ankle dorsiflexion and first metatarsal phalangeal joint range of motion (1st MPJ ROM), hallux valgus presence and severity. Twenty-three stroke participants (mean age 75.09 ± 7.57 years; 12 fallers) and 16 controls (mean age 73.44 ± 8.35 years) took part. Within the stroke group, reduced 1st MPJ sensation (p = 0.016) and 1st MPJ ROM (p = 0.025) were observed in the affected foot in comparison to the non-affected foot; no other differences were apparent. Pooled data (for both feet) was used to explore between stroke/control (n = 78 feet) and stroke faller/non-faller (n = 46 feet) group differences. In comparison to the control group, stroke participants exhibited reduced sensation of the 1st MPJ (p = 0.020), higher Foot Posture Index scores (indicating greater foot pronation, p = 0.008) and reduced foot function (p = 0.003). Stroke fallers exhibited significantly greater foot pronation in comparison to non-fallers (p = 0.027). Results indicated differences in foot and ankle characteristics post stroke in comparison to healthy controls. These changes may negatively impact functional ability and the ability to preserve balance. Further research is warranted to explore the influence of foot problems on balance ability and falls in people with stroke. Implications for Rehabilitation Foot problems are common post stroke. As foot problems have been linked to increased fall risk among the general population we recommend that it would be beneficial to include foot and ankle assessments or a referral to a podiatrist for people with stroke who report foot problems. Further research is needed to explore if we can improve functional

  2. Use and tolerability of a side pole static ankle foot orthosis in children with neurological disorders.

    Science.gov (United States)

    Delvert, Céline; Rippert, Pascal; Margirier, Françoise; Vadot, Jean-Pierre; Bérard, Carole; Poirot, Isabelle; Vuillerot, Carole

    2017-04-01

    Transverse-plane foot deformities are a frequently encountered issue in children with neurological disorders. They are the source of many symptoms, such as pain and walking difficulties, making their prevention very important. We aim to describe the use and tolerability of a side pole static ankle foot orthosis used to prevent transverse-plane foot deformities in children with neurologic disorders. Monocentric, retrospective, observational study. Medical data were collected from 103 children with transverse-plane foot deformities in one or both feet caused by a neurological impairment. All children were braced between 2001 and 2010. Unilateral orthosis was prescribed for 32 children and bilateral orthosis for 71. Transverse-plane foot deformities were varus in 66% of the cases and an equinus was associated in 59.2% of the cases. Mean age for the first prescription was 8.6 years. For the 23 patients present at the 4-year visit, 84.8% still wore the orthosis daily, and 64.7% wore the orthosis more than 6 h per day. The rate of permanent discontinuation of wearing the orthosis was 14.7%. The side pole static ankle foot orthosis is well tolerated with very few side effects, which promotes regular wearing and observance. Clinical relevance Side pole static ankle foot orthoses are well tolerated and can be safely used for children with foot abnormalities in the frontal plane that have a neurological pathology origin.

  3. The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness.

    Science.gov (United States)

    Shepherd, Max K; Rouse, Elliott J

    2017-12-01

    Most commercially available prosthetic feet do not exhibit a biomimetic torque-angle relationship, and are unable to modulate their mechanics to assist with other mobility tasks, such as stairs and ramps. In this paper, we present a quasi-passive ankle-foot prosthesis with a customizable torque-angle curve and an ability to quickly modulate ankle stiffness between tasks. The customizable torque-angle curve is obtained with a cam-based transmission and a fiberglass leaf spring. To achieve variable stiffness, the leaf spring's support conditions can be actively modulated by a small motor, shifting the torque-angle curve to be more or less stiff. We introduce the design, characterize the available torque-angle curves, and present kinematics from a transtibial amputee subject performing level-ground walking, stair ascent/descent, and ramp ascent/descent. The subject exhibited a more normative range of motion on stairs and ramps at lower stiffness levels, and preferred different stiffness levels for each task. Paired with an appropriate intent recognition system, our novel ankle prosthesis could improve gait biomechanics during walking and many other mobility tasks.

  4. Clinical negligence in foot and ankle surgery: A 17-year review of claims to the NHS Litigation Authority.

    Science.gov (United States)

    Ring, J; Talbot, C L; Clough, T M

    2014-11-01

    We present a review of litigation claims relating to foot and ankle surgery in the NHS in England during the 17-year period between 1995 and 2012. A freedom of information request was made to obtain data from the NHS litigation authority (NHSLA) relating to orthopaedic claims, and the foot and ankle claims were reviewed. During this period of time, a total of 10 273 orthopaedic claims were made, of which 1294 (12.6%) were related to the foot and ankle. 1036 were closed, which comprised of 1104 specific complaints. Analysis was performed using the complaints as the denominator. The cost of settling these claims was more than £36 million. There were 372 complaints (33.7%) involving the ankle, of which 273 (73.4%) were related to trauma. Conditions affecting the first ray accounted for 236 (21.4%), of which 232 (98.3%) concerned elective practice. Overall, claims due to diagnostic errors accounted for 210 (19.0%) complaints, 208 (18.8%) from alleged incompetent surgery and 149 (13.5%) from alleged mismanagement. Our findings show that the incorrect, delayed or missed diagnosis of conditions affecting the foot and ankle is a key area for improvement, especially in trauma practice. ©2014 The British Editorial Society of Bone & Joint Surgery.

  5. Driving reaction times in patients with foot and ankle pathology before and after image-guided injection: pain relief without improved function.

    Science.gov (United States)

    Talusan, Paul G; Miller, Christopher P; Save, Ameya V; Reach, John S

    2015-04-01

    Foot and ankle pathology is common in the driving population. Local anesthetic steroid injections are frequent ambulatory treatments. Brake reaction time (BRT) has validated importance in motor vehicle safety. There are no prior studies examining the effect of foot and ankle pathology and injection treatment on the safe operation of motor vehicles. We studied BRT in patients with foot and ankle musculoskeletal disease before and after image-guided injection treatment. A total of 37 participants were enrolled. Image-guided injections of local anesthetic and steroid were placed into the pathological anatomical location of the right or left foot and ankles. A driving reaction timer was used to measure BRTs before and after injection. Patients suffering right "driving" and left "nondriving" pathology as well as a healthy control group were studied. All patients reported >90% pain relief postinjection. All injections were confirmed to be accurate by imaging. Post hoc Bonferonni analysis demonstrated significant difference between the healthy group and the right-sided injection group (P = .008). Mean BRT for healthy controls was 0.57 ± 0.11 s. Patients suffering right foot and ankle disease displayed surprisingly high BRTs (0.80 ± 0.23 s preinjection and 0.78 ± 0.16 s postinjection, P > .99). Left nondriving foot and ankle pathology presented a driving hazard as well (BRT of 0.75 ± 0.12 s preinjection and 0.77 ± 0.12 s postinjection, P > .99). Injections relieved pain but did not significantly alter BRT (P > .99 for all). Patients suffering chronic foot and ankle pathology involving either the driving or nondriving side have impaired BRTs. This preexisting driving impairment has not previously been reported and exceeds recommended cutoff safety values in the United States. Despite symptom improvement, there was no statistically significant change in BRT following image-guided injection in either foot and ankle. Therapeutic, Level II: Prospective Comparative Study.

  6. Development of a Robotic Assembly for Analyzing the Instantaneous Axis of Rotation of the Foot Ankle Complex

    Directory of Open Access Journals (Sweden)

    Kelly N. Salb

    2016-01-01

    Full Text Available Ankle instantaneous axis of rotation (IAR measurements represent a more complete parameter for characterizing joint motion. However, few studies have implemented this measurement to study normal, injured, or pathological foot ankle biomechanics. A novel testing protocol was developed to simulate aspects of in vivo foot ankle mechanics during mid-stance gait in a human cadaveric specimen. A lower leg was mounted in a robotic testing platform with the tibia upright and foot flat on the baseplate. Axial tibia loads (ATLs were controlled as a function of a vertical ground reaction force (vGRF set at half body weight (356 N and a 50% vGRF (178 N Achilles tendon load. Two specimens were repetitively loaded over 10 degrees of dorsiflexion and 20 degrees of plantar flexion. Platform axes were controlled within 2 microns and 0.008 degrees resulting in ATL measurements within ±2 N of target conditions. Mean ATLs and IAR values were not significantly different between cycles of motion, but IAR values were significantly different between dorsiflexion and plantar flexion. A linear regression analysis showed no significant differences between slopes of plantar flexion paths. The customized robotic platform and advanced testing protocol produced repeatable and accurate measurements of the IAR, useful for assessing foot ankle biomechanics under different loading scenarios and foot conditions.

  7. SPECT/CT in imaging foot and ankle pathology-the demise of other coregistration techniques.

    Science.gov (United States)

    Mohan, Hosahalli K; Gnanasegaran, Gopinath; Vijayanathan, Sanjay; Fogelman, Ignac

    2010-01-01

    Disorders of the ankle and foot are common and given the complex anatomy and function of the foot, they present a significant clinical challenge. Imaging plays a crucial role in the management of these patients, with multiple imaging options available to the clinician. The American College of radiology has set the appropriateness criteria for the use of the available investigating modalities in the management of foot and ankle pathologies. These are broadly classified into anatomical and functional imaging modalities. Recently, single-photon emission computed tomography and/or computed tomography scanners, which can elegantly combine functional and anatomical images have been introduced, promising an exciting and important development. This review describes our clinical experience with single-photon emission computed tomography and/or computed tomography and discusses potential applications of these techniques.

  8. The benefit of pharmacological venous thromboprophylaxis in foot ...

    African Journals Online (AJOL)

    thromboprophylaxis in total hip replacement (THR), total knee replacement (TKR) and hip fractures have been well documented in published literature and in clinical trials.[1,7-10]. Although there is potentially an increased risk of VTE in foot and ankle surgery, the incidence of VTE is poorly understood. None of the available ...

  9. Foot loading with an ankle-foot orthosis: the accuracy of an integrated physical strain trainer.

    Science.gov (United States)

    Pauser, Johannes; Jendrissek, Andreas; Brem, Matthias; Gelse, Kolja; Swoboda, Bernd; Carl, Hans-Dieter

    2012-07-01

    To investigate the value of a built-in physical strain trainer for the monitoring of partial weight bearing with an ankle-foot orthosis. 12 healthy volunteers were asked to perform three trials. Plantar peak pressure values from normal gait (trial one) were defined as 100% (baseline). The following trials were performed with the Vacoped® dynamic vacuum ankle orthosis worn in a neutral position with full weight bearing (trial two) and a restriction to 10% body weight (BW) (trial three), as monitored with an integrated physical strain trainer. Peak plantar pressure values were obtained using the pedar® X system. Peak pressure values were statistically significantly reduced wearing the Vacoped® shoe with full weight bearing for the hindfoot to 68% of the baseline (normal gait) and for the midfoot and forefoot to 83% and 60%, respectively. Limited weight bearing with 10% BW as controlled by physical strain trainer further reduced plantar peak pressure values for the hindfoot to 19%, for the midfoot to 43% of the baseline and the forefoot to 22% of the baseline. The Vacoped® vacuum ankle orthosis significantly reduces plantar peak pressure. The integrated physical strain trainer seems unsuitable to monitor a limitation to 10% BW adequately for the total foot. The concept of controlling partial weight bearing with the hindfoot-addressing device within the orthosis seems debatable but may be useful when the hindfoot in particular must be off-loaded.

  10. Vibrotactile stimulation of fast-adapting cutaneous afferents from the foot modulates proprioception at the ankle joint.

    Science.gov (United States)

    Mildren, Robyn L; Bent, Leah R

    2016-04-15

    It has previously been shown that cutaneous sensory input from across a broad region of skin can influence proprioception at joints of the hand. The present experiment tested whether cutaneous input from different skin regions across the foot can influence proprioception at the ankle joint. The ability to passively match ankle joint position (17° and 7° plantar flexion and 7° dorsiflexion) was measured while cutaneous vibration was applied to the sole (heel, distal metatarsals) or dorsum of the target foot. Vibration was applied at two different frequencies to preferentially activate Meissner's corpuscles (45 Hz, 80 μm) or Pacinian corpuscles (255 Hz, 10 μm) at amplitudes ∼3 dB above mean perceptual thresholds. Results indicated that cutaneous input from all skin regions across the foot could influence joint-matching error and variability, although the strongest effects were observed with heel vibration. Furthermore, the influence of cutaneous input from each region was modulated by joint angle; in general, vibration had a limited effect on matching in dorsiflexion compared with matching in plantar flexion. Unlike previous results in the upper limb, we found no evidence that Pacinian input exerted a stronger influence on proprioception compared with Meissner input. Findings from this study suggest that fast-adapting cutaneous input from the foot modulates proprioception at the ankle joint in a passive joint-matching task. These results indicate that there is interplay between tactile and proprioceptive signals originating from the foot and ankle. Copyright © 2016 the American Physiological Society.

  11. Provocative mechanical tests of the peripheral nervous system affect the joint torque-angle during passive knee motion.

    Science.gov (United States)

    Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P

    2015-06-01

    This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P torque (P torque when the cervical and thoracic spines were flexed (P torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Psychometric properties of the foot and ankle outcome score in a community-based study of adults with and without osteoarthritis

    DEFF Research Database (Denmark)

    Golightly, Yvonne M; Devellis, Robert F; Nelson, Amanda E

    2014-01-01

    Objective. Foot and ankle problems are common in adults, and large observational studies are needed to advance our understanding of the etiology and impact of these conditions. Valid and reliable measures of foot and ankle symptoms and physical function are necessary for this research. This study...

  13. Multisegmental Foot and Ankle Motion Analysis After Hallux Valgus Surgery

    Science.gov (United States)

    Canseco, Karl; Long, Jason; Smedberg, Thomas; Tarima, Sergey; Marks, Richard M.; Harris, Gerald F.

    2015-01-01

    Background Gait changes in patients with hallux valgus, including altered kinematic and temporal-spatial parameters, have been documented in the literature. Although operative treatment can yield favorable clinical and radiographic results, restoration of normal gait in this population remains unclear. Segmental kinematic changes within the foot and ankle during ambulation after operative correction of hallux valgus have not been reported. The aim of this study was to analyze changes in multisegmental foot and ankle kinematics in patients who underwent operative correction of hallux valgus. Methods A 15-camera Vicon Motion Analysis System was used to evaluate 24 feet in 19 patients with hallux valgus preoperatively and postoperatively. The Milwaukee Foot Model was used to characterize segmental kinematics and temporal-spatial parameters (TSPs). Preoperative and postoperative kinematics and TSPs were compared using paired nonparametric methods; comparisons with normative data were performed using unpaired nonparametric methods. Outcomes were evaluated using the SF-36 assessment tool. Results Preoperatively, patients with hallux valgus showed significantly altered temporal-spatial and kinematic parameters. Postoperatively, kinematic analysis demonstrated restoration of hallux position to normal. Hallux valgus angles and intermetatarsal angles were significantly improved, and outcomes showed a significant increase in performance of physical activities. Temporal-spatial parameters and kinematics in the more proximal segments were not significantly changed postoperatively. Conclusion Postoperative results demonstrated significant improvement in foot geometry and hallux kinematics in the coronal and transverse planes. However, the analysis did not identify restoration of proximal kinematics. Clinical Relevance Further investigation is necessary to explore possible causes/clinical relevance and appropriate treatment interventions for the persistently altered kinematics

  14. Adipofascial sural artery flap for foot and ankle reconstruction in children: for better aesthetic outcome

    International Nuclear Information System (INIS)

    Mahmood, F.

    2015-01-01

    Wheel spoke injury of the ankle and foot is very common in children and its reconstruction is challenging. Reverse flow sural artery fasciocutaneous flap is versatile for this area but lead to significant donor site morbidity. Free tissue transfer is an option in children which needs a micro-vascular expertise, expensive equipment and long operating time. Method: Fifteen adipofascial flaps were done for foot and ankle coverage from June 2011 to June 2014 at CH and ICH Lahore. The efficacy of adipofascial sural artery flap for the coverage of these defects was evaluated. Results: Fifteen children presented with defects of foot and ankle, 11 (73%) were male and 4 (27%) were female. Their age ranged from 1 - 13 years. All patients had trauma to the foot due to wheel spoke injury. Flaps were used to cover tendoachilles and malleoli. In one patient there was flap tip necrosis with partial graft loss which healed with dressings. Donor site aesthetic outcome was satisfactory in all cases. Mean follow-up was I year. Conclusion: Adipofascial Sural artery flap is quick and safe with wide arc of rotation, minimal donor site morbidity and better aesthetic outcome and it does not sacrifice major extremity vessel. (author)

  15. Venous Thromboembolism in Podiatric Foot and Ankle Surgery.

    Science.gov (United States)

    Matthews, Jemma H; Terrill, Alexander J; Barwick, Alex L; Butterworth, Paul A

    2018-01-01

    The extent to which podiatric surgeons follow venous thromboembolism guidelines is unknown. The aim of this study therefore, was 2-fold: (a) to determine the rate of venous thromboembolism following podiatric surgery and (b) to investigate the factors that influence the use of thromboprophylaxis. Data from 4238 patients who underwent foot and ankle surgery over 2 years were analyzed. Venous thromboembolism within the first 30 days following surgery was recorded using the Australasian College of Podiatric Surgeons surgical audit tool. Logistic regression analyses were undertaken to determine the factors that influenced thromboprophylaxis. Of the 4238 patient records, 3677 records (87%) provided complete data (age range 2-94 years; mean ± SD, 49.1 ± 19.7 years; 2693 females). A total of 7 venous thromboembolic events (0.2% rate) were reported. Operative duration and age (OR 12.63, 95% CI 9.47 to 16.84, P < 0.01), postoperative immobilization (OR 6.94, 95% CI 3.95 to 12.20, P < 0.01), and a prior history of VTE (OR 3.41, 95% CI 1.01 to 11.04, P = 0.04) were the strongest predictors of thromboprophylaxis. Podiatric foot and ankle surgery is associated with a low rate of venous thromboembolism. This may be due in part to the thromboprophylaxis regime implemented by podiatric surgeons, which closely aligns with current evidence-based guidelines. Level II: Prospective cohort study.

  16. Factors associated with nonunion, delayed union, and malunion in foot and ankle surgery in diabetic patients.

    Science.gov (United States)

    Shibuya, Naohiro; Humphers, Jon M; Fluhman, Benjamin L; Jupiter, Daniel C

    2013-01-01

    The incidence of bone healing complications in diabetic patients is believed to be high after foot and ankle surgery. Although the association of hyperglycemia with bone healing complications has been well documented, little clinical information is available to show which diabetes-related comorbidities directly affect bone healing. Our goal was to better understand the risk factors associated with poor bone healing in the diabetic population through an exploratory, observational, retrospective, cohort study. To this end, 165 diabetic patients who had undergone arthrodesis, osteotomy, or fracture reduction were enrolled in the study to assess the risk factors associated with nonunion, delayed union, and malunion after elective and nonelective foot and/or ankle surgery. Bivariate analyses showed that a history of foot ulcer, peripheral neuropathy, and surgery duration were statistically significantly associated with bone healing complications. After adjusting for other covariates, only peripheral neuropathy, surgery duration, and hemoglobin A1c levels >7% were significantly associated statistically with bone healing complications. Of the risk factors we considered, peripheral neuropathy had the strongest association with bone healing complications. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Publication Rates for Oral Manuscript and Poster Presentations From the American College of Foot and Ankle Surgeons: 2010 to 2014.

    Science.gov (United States)

    Rushing, Calvin J; Galan, Gabriel P; Ivankiv, Roman; Oxios, Adam J; Rathnayake, Viraj R; Ramil, Madelin C; Chussid, Fredric; Spinner, Steven M

    2018-04-26

    The American College of Foot and Ankle Surgeons (ACFAS) annual conference has served as a premiere platform to disseminate the latest innovations and research in the field of foot and ankle surgery. The quality of national society conferences is often assessed indirectly by analyzing the the journal publication rate of the abstracts presented. The purpose of this retrospective study was to assess the journal publication rate for abstracts (oral manuscripts and posters) accepted for presentation at the ACFAS conference from 2010 to 2014. All accepted abstracts from this period were compiled by the ACFAS office. PubMed, Google Scholar, and Scopus searches were performed using abstract titles and author names. Overall, the journal publication rate was 76.9% (83 of 108) for oral manuscripts and 23.2% (258 of 1113) for poster abstracts. The mean time to publication was 9.6 (range 0 to 44) months and 19.8 (range 0 to 66) months for oral and poster abstracts, respectively. The most common journal for abstract publication was The Journal of Foot and Ankle Surgery. Notably, the ACFAS oral manuscript publication rate from 2010 to 2014 (76.9%) exceeded its previously reported rate from 1999 to 2008 (67.5%) and the American Orthopaedic Foot and Ankle Society podium publication rate from 2008 to 2012 (73.7%). To the best of our knowledge, the publication incidence for oral abstracts presented at the ACFAS conference is now the highest reported of any national foot and ankle society conference to date. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Reconstruction of soft tissue defects around the ankle and foot

    Directory of Open Access Journals (Sweden)

    Bharat Bhushan Dogra

    2014-01-01

    Full Text Available Introduction: Soft tissue defects over ankle and foot region are encountered quite frequently following road traffic trauma and surgery. Management of such cases is a challenging task for any reconstructive surgeon because of paucity of skin and relative poor vascular status of skin in this region. Hence, invariably such cases require microsurgical free flap coverage, expertise for which may not be available at all the centers, such procedures require long operating hours and suitable recipient vessel may not be available in crush injuries. Materials and Methods: Thirty consecutive patients having soft tissue defects around ankle and foot region who underwent various reconstructive procedures in a medical college hospital during last 2 years form the basis of this study. This study was carried out to enlist various etiological factors and reconstructive surgical procedures employed to manage such cases without microsurgery. Results: The age of these patients ranged from 9 to 72 years. Twenty-five patients were males while 05 were females, with a mean age of 25 years. Road traffic accidents happened to be the primary cause of such defects in as many as 15 patients, cycle spoke trauma in 02 patients, implant exposure following orthopedic surgery in 6 patients, diabetic angiopathy in 4 patients and chronic osteomyelitis in 3 patients. The site of the defect was lower fourth of tibia in 16 patients, dorsum of foot in 2 patients, sole in 5 patients, medial aspect of ankle in 02 cases, lateral aspect in 02 cases and retro calcaneal region in 03 cases. In 10 cases distally based superficial sural artery flap was used to reconstruct the defect. In step rotation flap was used to provide sensory flap cover in the weight bearing heel in 04 cases. Inferiorly based fasciocutanenous flaps in 09 cases and muscle flaps were used in 07 cases. Conclusion: Distally based sural artery based flaps are very handy to provide skin cover around ankle and malleolar

  19. Load eccentricity effects on behavior of circular footings reinforced with geogrid sheets

    Directory of Open Access Journals (Sweden)

    Ehsan Badakhshan

    2015-12-01

    Full Text Available In this paper, an experimental study for an eccentrically loaded circular footing, resting on a geogrid reinforced sand bed, is performed. To achieve this aim, the steel model footing of 120 mm in diameter and sand in relative density of 60% are used. Also, the effects of depth of first and second geogrid layers and number of reinforcement layers (1–4 on the settlement-load response and tilt of footing under various load eccentricities (0 cm, 0.75 cm, 1.5 cm, 2.25 cm and 3 cm are investigated. Test results indicate that ultimate bearing capacity increases in comparison with unreinforced condition. It is observed that when the reinforcements are placed in the optimum embedment depth (u/D = 0.42 and h/D = 0.42, the bearing capacity ratio (BCR increases with increasing load eccentricity to the core boundary of footing, and that with further increase of load eccentricity, the BCR decreases. Besides, the tilt of footing increases linearly with increasing settlement. Finally, by reinforcing the sand bed, the tilt of footing decreases at 2 layers of reinforcement and then increases by increasing the number of reinforcement layers.

  20. Effects of balance training by knee joint motions on muscle activity in adult men with functional ankle instability.

    Science.gov (United States)

    Nam, Seung-Min; Kim, Won-Bok; Yun, Chang-Kyo

    2016-05-01

    [Purpose] This study examined the effects of balance training by applying knee joint movements on muscle activity in male adults with functional ankle instability. [Subjects and Methods] 28 adults with functional ankle instability, divided randomly into an experimental group, which performed balance training by applying knee joint movements for 20 minutes and ankle joint exercises for 10 minutes, and a control group, which performed ankle joint exercise for 30 minutes. Exercises were completed three times a week for 8 weeks. Electromyographic values of the tibialis anterior, peroneus longus, peroneus brevis, and the lateral gastrocnemius muscles were obtained to compare and analyze muscle activity before and after the experiments in each group. [Results] The experimental group had significant increases in muscle activity in the tibialis anterior, peroneus longus, and lateral gastrocnemius muscles, while muscle activity in the peroneus brevis increased without significance. The control group had significant increases in muscle activity in the tibialis anterior and peroneus longus, while muscle activity in the peroneus brevis and lateral gastrocnemius muscles increased without significance. [Conclusion] In conclusion, balance training by applying knee joint movements can be recommended as a treatment method for patients with functional ankle instability.

  1. Generation of subject-specific, dynamic, multisegment ankle and foot models to improve orthotic design: a feasibility study

    Directory of Open Access Journals (Sweden)

    Oosterwaal Michiel

    2011-11-01

    Full Text Available Abstract Background Currently, custom foot and ankle orthosis prescription and design tend to be based on traditional techniques, which can result in devices which vary greatly between clinicians and repeat prescription. The use of computational models of the foot may give further insight in the biomechanical effects of these devices and allow a more standardised approach to be taken to their design, however due to the complexity of the foot the models must be highly detailed and dynamic. Methods/Design Functional and anatomical datasets will be collected in a multicentre study from 10 healthy participants and 15 patients requiring orthotic devices. The patient group will include individuals with metarsalgia, flexible flat foot and drop foot. Each participant will undergo a clinical foot function assessment, 3D surface scans of the foot under different loading conditions, and detailed gait analysis including kinematic, kinetic, muscle activity and plantar pressure measurements in both barefoot and shod conditions. Following this each participant will undergo computed tomography (CT imaging of their foot and ankle under a range of loads and positions while plantar pressures are recorded. A further subgroup of participants will undergo magnetic resonance imaging (MRI of the foot and ankle. Imaging data will be segmented to derive the geometry of the bones and the orientation of the joint axes. Insertion points of muscles and ligaments will be determined from the MRI and CT-scans and soft tissue material properties computed from the loaded CT data in combination with the plantar pressure measurements. Gait analysis data will be used to drive the models and in combination with the 3D surface scans for scaling purposes. Predicted plantar pressures and muscle activation patterns predicted from the models will be compared to determine the validity of the models. Discussion This protocol will lead to the generation of unique datasets which will be used

  2. Incidence of Complex Regional Pain Syndrome I Following Foot and Ankle Fractures Using the Budapest Criteria.

    Science.gov (United States)

    Bullen, Michael; Lang, Coran; Tran, Phong

    2016-12-01

    OBJECTIVE : Fractures are a well-recognized inciting event in the development of complex regional pain syndrome. This study aimed to prospectively determine the incidence of complex regional pain syndrome following foot and ankle fractures. METHODS : A prospective study was conducted of patients presenting to two metropolitan hospitals with plain radiograph diagnosis of fractures to the foot or ankle. Patients were initially screened by phone 3 months after injury using the validated International Association for the Study of Pain Budapest criteria. Patients who fulfilled the screening criteria were then physically examined by a pain specialist to assess clinical signs as part of the Budapest criteria. RESULTS : A total of 306 consecutive eligible patients were included. One hundred and ten patients reported at least one symptom of complex regional pain syndrome; however, only three fulfilled the minimum requirements to necessitate clinical review. Of these three, only one patient fulfilled the combination of symptom and sign criteria for a positive diagnosis according to the validated Budapest criteria. The incidence of complex regional pain syndrome following foot and ankle fracture in this study was 0.3%. CONCLUSION : Although many patients may experience vasomotor, sensory, and sudomotor disturbance following a fracture to the foot and ankle, the observed incidence of complex regional pain syndrome using a prospectively collected validated criteria is significantly lower than previously published. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Propulsion System with Pneumatic Artificial Muscles for Powering Ankle-Foot Orthosis

    Science.gov (United States)

    Veneva, Ivanka; Vanderborght, Bram; Lefeber, Dirk; Cherelle, Pierre

    2013-12-01

    The aim of this paper is to present the design of device for control of new propulsion system with pneumatic artificial muscles. The propulsion system can be used for ankle joint articulation, for assisting and rehabilitation in cases of injured ankle-foot complex, stroke patients or elderly with functional weakness. Proposed device for control is composed by microcontroller, generator for muscles contractions and sensor system. The microcontroller receives the control signals from sensors and modulates ankle joint flex- ion and extension during human motion. The local joint control with a PID (Proportional-Integral Derivative) position feedback directly calculates desired pressure levels and dictates the necessary contractions. The main goal is to achieve an adaptation of the system and provide the necessary joint torque using position control with feedback.

  4. A Modified Suture Bridge Technique for Application With Bone Anchors in Foot and Ankle Surgery.

    Science.gov (United States)

    Walters, Jeremy; Correa, Christopher; Moss, Mark

    2015-01-01

    We present a suture bridge technique for reattachment of tendon or ligament to bone for use in foot and ankle surgery. The method is a simple, strong, and reproducible technique that could decrease the risk of irritation of the overlying cutaneous barrier and minimizes the likelihood of tendon strangulation when combined with soft tissue bone anchors. The present report serves as a guide to the use of this suture technique for reattachment of the Achilles tendon. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Chinese cross-cultural adaptation and validation of the Foot Function Index as tool to measure patients with foot and ankle functional limitations.

    Science.gov (United States)

    González-Sánchez, Manuel; Ruiz-Muñoz, Maria; Li, Guang Zhi; Cuesta-Vargas, Antonio I

    2017-05-11

    To perform a cross-cultural adaptation and validation of the Foot Function Index (FFI) questionnaire to develop the Chinese version. Three hundred and six patients with foot and ankle neuromusculoskeletal diseases participated in this observational study. Construct validity, internal consistency and criterion validity were calculated for the FFI Chinese version after the translation and transcultural adaptation process. Internal consistency ranged from 0.996 to 0.998. Test-retest analysis ranged from 0.985 to 0.994; minimal detectable change 90: 2.270; standard error of measurement: 0.973. Load distribution of the three factors had an eigenvalue greater than 1. Chi-square value was 9738.14 (p Foot Function Index (Taiwan Version), Short-Form 12 (Version 2) and EuroQol-5D were used for criterion validity. Factors 1 and 2 showed significant correlation with 15/16 and 14/16 scales and subscales, respectively. Foot Function Index Chinese version psychometric characteristics were good to excellent. Chinese researchers and clinicians may use this tool for foot and ankle assessment and monitoring. Implications for rehabilitation A cross-cultural adaptation of the FFI has been done from original version to Chinese. Consistent results and satisfactory psychometric properties of the Foot Function Index Chinese version have been reported. For Chinese speaking researcher and clinician FFI-Ch could be used as a tool to assess patients with foot disease.

  6. Effect of Ankle-foot Orthosis on Lower Limb Muscle Activities and Static Balance of Stroke Patients Authors’ Names

    OpenAIRE

    Lee, Youngmin; Her, Jin Gang; Choi, Youngeun; Kim, Heesoo

    2014-01-01

    [Purpose] This study examined the effects of an ankle-foot orthosis worn during balance training on lower limb muscle activity and static balance of chronic stroke patients. [Subjects] The subjects were twenty-five inpatients receiving physical therapy for chronic stroke. [Methods] The chronic stroke patients were divided into two groups: thirteen patients were assigned to the ankle-foot orthosis group, while the remaining twelve patients wore only their shoes. Each group performed balance tr...

  7. Relevance of adjacent joint imaging in the evaluation of ankle fractures.

    Science.gov (United States)

    Antoci, Valentin; Patel, Shaun P; Weaver, Michael J; Kwon, John Y

    2016-10-01

    Routinely obtaining adjacent joint radiographs when evaluating patients with ankle fractures may be of limited clinical utility and an unnecessary burden, particularly in the absence of clinical suspicion for concomitant injuries. One thousand, three hundred and seventy patients who sustained ankle fractures over a 5-year period presenting to two level 1 trauma centers were identified. Medical records were retrospectively reviewed for demographics, physical examination findings, and radiographic information. Analyses included descriptive statistics along with sensitivity and predictive value calculations for the presence of adjacent joint fracture. Adjacent joint imaging (n=1045 radiographs) of either the knee or foot was obtained in 873 patients (63.7%). Of those, 75/761 patients (9.9%) demonstrated additional fractures proximal to the ankle joint, most commonly of the proximal fibula. Twenty-two of 284 (7.7%) demonstrated additional fractures distal to the ankle joint, most commonly of the metatarsals. Tenderness to palpation demonstrated sensitivities of 0.92 and 0.77 and positive predictive values of 0.94 and 0.89 for the presence of proximal and distal fractures, respectively. Additionally, 19/22 (86.4%) of patients sustaining foot fractures had their injury detectable on initial ankle X-rays. Overall, only 5.5% (75/1370) of patients sustained fractures proximal to the ankle and only 0.2% (3/1370) of patients had additional foot fractures not evident on initial ankle X-rays. The addition of adjacent joint imaging for the evaluation of patients sustaining ankle fractures is low yield. As such, patient history, physical examination, and clinical suspicion should direct the need for additional X-rays. Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Forefoot strikers exhibit lower running-induced knee loading than rearfoot strikers.

    Science.gov (United States)

    Kulmala, Juha-Pekka; Avela, Janne; Pasanen, Kati; Parkkari, Jari

    2013-12-01

    Knee pain and Achilles tendinopathies are the most common complaints among runners. The differences in the running mechanics may play an important role in the pathogenesis of lower limb overuse injuries. However, the effect of a runner's foot strike pattern on the ankle and especially on the knee loading is poorly understood. The purpose of this study was to examine whether runners using a forefoot strike pattern exhibit a different lower limb loading profile than runners who use rearfoot strike pattern. Nineteen female athletes with a natural forefoot strike (FFS) pattern and pair-matched women with rearfoot strike (RFS) pattern (n = 19) underwent 3-D running analysis at 4 m·s⁻¹. Joint angles and moments, patellofemoral contact force and stresses, and Achilles tendon forces were analyzed and compared between groups. FFS demonstrated lower patellofemoral contact force and stress compared with heel strikers (4.3 ± 1.2 vs 5.1 ± 1.1 body weight, P = 0.029, and 11.1 ± 2.9 vs 13.0 ± 2.8 MPa, P = 0.04). In addition, knee frontal plane moment was lower in the FFS compared with heel strikers (1.49 ± 0.51 vs 1.97 ± 0.66 N·m·kg⁻¹, P =0.015). At the ankle level, FFS showed higher plantarflexor moment (3.12 ± 0.40 vs 2.54 ± 0.37 N·m·kg⁻¹; P = 0.001) and Achilles tendon force (6.3 ± 0.8 vs 5.1 ± 1.3 body weight; P = 0.002) compared with RFS. To our knowledge, this is the first study that shows differences in patellofemoral loading and knee frontal plane moment between FFS and RFS. FFS exhibit both lower patellofemoral stress and knee frontal plane moment than RFS, which may reduce the risk of running-related knee injuries. On the other hand, parallel increase in ankle plantarflexor and Achilles tendon loading may increase risk for ankle and foot injuries.

  9. MRI abnormalities of foot and ankle in asymptomatic, physically active individuals

    International Nuclear Information System (INIS)

    Lohman, M.; Kivisaari, A.; Kivisaari, L.; Kallio, P.

    2001-01-01

    Objective. To assess MRI changes in the ankle and foot after physical exercise.Design and patients. Nineteen non-professional marathon runners and 19 age- and sex-matched controls volunteered for the study. All had ankle and foot MR images (1.5 T) taken in three perpendicular planes (STIR, T2F and T1FS sequences) within 3 h of running a full-length marathon (42.125 km). Three radiologists independently analysed the groups on a masked basis using a predefined form.Results. Severe bone marrow oedema was seen in one and slight bone marrow oedema in three marathon runners. Slight bone marrow oedema was found in three control subjects. Signal alteration within the soleus muscle, consistent with a grade 1 strain, was found in one marathon runner. Small punctate hyperintensities within the Achilles tendon were seen in 26% of the marathon runners and in 63% of controls (P=0.016). An increased amount of fluid in the retrocalcaneal bursa was found in one control and in none of the marathon runners. Small amounts of fluid in the retrocalcaneal bursa were seen in 68% of marathon runners and in 53% of controls. Grade 1 or 2 peritendinous joint fluid was found around 22% of tendons, among both marathon runners and controls, most often involving the tendon sheath of the flexor hallucis longus muscle. An increased amount of joint fluid was noted in 34% of the joints of the marathon runners, and in 18% of the controls.Conclusion. MRI shows several abnormalities in the ankle and foot both after marathon races and in asymptomatic physically active individuals without any preceding extraordinary strain. Recreational sports may lead to a number of positive MRI findings without correlation with clinical findings. (orig.)

  10. Study of occurrence, demography and pathomorphology of ankle and foot fractures and evaluation of the treatment outcome of calcaneal fractures

    International Nuclear Information System (INIS)

    Sarfraz, A.H.; Masood, F.

    2014-01-01

    This study highlights which injury has greatest burden, how frequent are the injuries of foot and ankle areas, which is an extremely neglected specialty in orthopedics and also the importance of proper diagnosis, classification of fractures, appropriate pre-operative planning and timely conservative as well as surgical intervention of ankle and foot fractures that resulted in a satisfactory outcome Despite the fact, foot and ankle is the most important locomotor unit of our lower limb, there have been few studies addressing the problem and treatment outcome of such fractures. Objective: To determine the occurrence, demography and pathomorphology of ankle and foot fractures, also evaluation of treatment outcome of calcaneal fractures. Methodology: This was a longitudinal interventional study which dealt with acute traumatic ankle and foot fracture patients coming to Accident and Emergency Department of MHL, DOST unit 1, with inclusion and exclusion criteria clearly defined. Results: Total 100 patients were included in the study. Mean age of patients was 35.71+-13.60 years. Minimum age of patients was 14 and maximum age of patients was 70 years respectively. Gender distribution of patients shows that 15 patients were female and the remaining 85 patients were male. Male patients were greater in number as compared to female patients ie. M: F, 6:1. Mechanism of the injury showed that there were 48 patients who suffered from RTA , 37 patients had trauma due to fall from height, 6 patients had industrial injuries, 5 patients had Fire Arm Injury, and 2 patients had injuries due to domestic activity, 1 had trauma due to sports activity and 1 had injury due to agricultural work. There were 41 patients with fractures of calcaneum and out of which 5 had bilateral fracture calcaneum. They were classified according to CT based Sanders classification. Out of these 22 patients were of Sanders type III, 12 patients were of Sander type II, 5 patients were of Sander type IV, 2

  11. [Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].

    Science.gov (United States)

    Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua

    2017-03-01

    To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.

  12. Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking

    OpenAIRE

    Caputo, Joshua M.; Collins, Steven H.

    2014-01-01

    Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementall...

  13. Tibialis Anterior Tendon: A Reliable Anatomical Landmark Indicating the Ankle Centre. Potential Utility in Extra-Medullary Alignment During Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Avadhoot P. Kantak

    2017-07-01

    Full Text Available Background Extramedullary alignment is a well established surgical technique during total knee replacement. There are different methods to achieve accuracy but variability is quite extensive. To attain uniformity in the surgical technique we have been using the tibialis tendon to align our resection guide. This may prove to be a useful aid for surgeons during knee replacement surgery. Objectives The purpose of our study was to establish if tibialis anterior tendon represents the centre of ankle joint and if it could be used as an anatomical reference for alignment during knee replacement. Methods We designed a retrospective radiological cohort study. We studied sixty MRI scans of normal ankles. The centre of ankle joint was marked as a bisection point of the intermalleolar line at the level of superior surface of the talus. A line was drawn connecting the centre of Achilles tendon to the ankle centre and this was extended anteriorly. This line was found to have a constant relation to the ankle centre and it would simulate the positioning of the standard alignment device used. Results The tibialis anterior tendon lies less than 3mm medial to the ankle centre in the frontal plane. Conclusions We conclude that the tibialis anterior tendon can be used during knee replacement surgery as an accurate alignment guide.

  14. Accessory ossicles and sesamoid bones of the ankle and foot: imaging findings, clinical significance and differential diagnosis

    International Nuclear Information System (INIS)

    Mellado, J.M.; Ramos, A.; Salvado, E.; Camins, A.; Sauri, A.; Danus, M.

    2003-01-01

    Accessory ossicles and sesamoid bones are frequent findings in routine radiographs of the ankle and foot. They are commonly considered fortuitous and unrelated to the patient's complaint; however, they may eventually cause painful syndromes or degenerative changes in response to overuse and trauma. They may also suffer or simulate fractures. Our aim was to review, illustrate and discuss the imaging findings of some of the more frequent accessory ossicles and sesamoid bones of the ankle and foot region, with particular emphasis on those that may be of clinical significance or simulate fractures. (orig.)

  15. [The behavior of fiber-reinforced plastics during laser cutting].

    Science.gov (United States)

    Emmrich, M; Levsen, K; Trasser, F J

    1992-06-01

    The pattern of the organic emissions, which are produced by processing of fibre reinforced plastics (epoxy resins reinforced by aramid and glass fibres and phenol resins reinforced by aramid fibre) with laser beam was studied and the concentrations of the main components determined. Despite the application of plastic materials with different chemical structures, the observed patterns are very similar. Mainly aromatic hydrocarbons are emitted, especially benzene and toluene, as well as some heteroatom-containing aromatic hydrocarbons (e.g. phenol). By use of oxygen as process gas the emissions during cutting of glass fibre reinforced plastics can be reduced, while they will be constantly high with aramid fibre reinforced plastics.

  16. Using the Oxford Foot Model to determine the association between objective measures of foot function and results of the AOFAS Ankle-Hindfoot Scale and the Foot Function Index: a prospective gait analysis study in Germany.

    Science.gov (United States)

    Kostuj, Tanja; Stief, Felix; Hartmann, Kirsten Anna; Schaper, Katharina; Arabmotlagh, Mohammad; Baums, Mike H; Meurer, Andrea; Krummenauer, Frank; Lieske, Sebastian

    2018-04-05

    After cross-cultural adaption for the German translation of the Ankle-Hindfoot Scale of the American Orthopaedic Foot and Ankle Society (AOFAS-AHS) and agreement analysis with the Foot Function Index (FFI-D), the following gait analysis study using the Oxford Foot Model (OFM) was carried out to show which of the two scores better correlates with objective gait dysfunction. Results of the AOFAS-AHS and FFI-D, as well as data from three-dimensional gait analysis were collected from 20 patients with mild to severe ankle and hindfoot pathologies.Kinematic and kinetic gait data were correlated with the results of the total AOFAS scale and FFI-D as well as the results of those items representing hindfoot function in the AOFAS-AHS assessment. With respect to the foot disorders in our patients (osteoarthritis and prearthritic conditions), we correlated the total range of motion (ROM) in the ankle and subtalar joints as identified by the OFM with values identified during clinical examination 'translated' into score values. Furthermore, reduced walking speed, reduced step length and reduced maximum ankle power generation during push-off were taken into account and correlated to gait abnormalities described in the scores. An analysis of correlations with CIs between the FFI-D and the AOFAS-AHS items and the gait parameters was performed by means of the Jonckheere-Terpstra test; furthermore, exploratory factor analysis was applied to identify common information structures and thereby redundancy in the FFI-D and the AOFAS-AHS items. Objective findings for hindfoot disorders, namely a reduced ROM, in the ankle and subtalar joints, respectively, as well as reduced ankle power generation during push-off, showed a better correlation with the AOFAS-AHS total score-as well as AOFAS-AHS items representing ROM in the ankle, subtalar joints and gait function-compared with the FFI-D score.Factor analysis, however, could not identify FFI-D items consistently related to these three

  17. The location of the peroneus longus tendon in the cuboid groove: sonographic study in various positions of the ankle-foot in asymptomatic volunteers.

    Science.gov (United States)

    Choo, Hye Jung; Lee, Sun Joo; Huang, Brady K; Resnick, Donald L

    2018-04-10

    To evaluate the normal location of the peroneus longus tendon (PL) in the cuboid groove in various ankle-foot positions by ultrasonography in asymptomatic volunteers. Ultrasonographic assessment of the PL in the cuboid groove was performed in 20 feet of ten healthy volunteers. Each PL was examined in five ankle-foot positions (i.e., neutral, dorsiflexion, plantar-flexion, supination, and pronation). The PL location was qualitatively categorized as "inside" when the PL was entirely within the cuboid groove, as "overlying" when some part of the PL was perched on the cuboid tuberosity, and as "outside" when the PL was entirely on the cuboid tuberosity. For quantitative evaluation of the PL location, the distance between the PL and the cuboid groove was measured. The width of the cuboid groove was measured in the neutral position. The PL location did not significantly change with changes in the ankle-foot position. Qualitatively, an "overlying" PL was the most common type, regardless of the ankle-foot position. "Inside" PLs were found in only 35, 20, 30, 25, and 35% of feet in neutral, dorsiflexion, plantar-flexion, supination, and pronation positions, respectively. The quantitative PL location was also not significantly different among all ankle-foot positions and it was significantly negatively correlated with the cuboid groove width. In healthy volunteers, 65% or more of the PLs were partially or completely located outside of the cuboid groove, regardless of the ankle-foot position. The PL location relative to the cuboid groove was related to the cuboid groove width.

  18. MDCT classification of osseous ankle and foot injuries

    International Nuclear Information System (INIS)

    Opherk, J.P.; Rosenthal, H.; Galanski, M.

    2007-01-01

    Conventional radiography plays an essential role in the primary evaluation of acute ankle and foot trauma. In the case of complex injuries, however, subsequent computed tomography (CT) is nowadays recommended. In this connection, multidetector computed tomography (MDCT) allows better temporal, spatial, and contrast resolution compared with the conventional single-slice spiral CT. Multiplanar reformation and three-dimensional reconstruction of the acquired data sets are also helpful tools for critical assessment of therapeutic intervention. This report reviews the potential of the MDCT technique for accurate fracture classification, precise illustration of displaced components, and postoperative control of arrangement of typical lesions. (orig.) [de

  19. Stress fractures of the foot and ankle, part 2: site-specific etiology, imaging, and treatment, and differential diagnosis.

    Science.gov (United States)

    Mandell, Jacob C; Khurana, Bharti; Smith, Stacy E

    2017-09-01

    Stress fractures of the foot and ankle are a commonly encountered problem among athletes and individuals participating in a wide range of activities. This illustrated review, the second of two parts, discusses site-specific etiological factors, imaging appearances, treatment options, and differential considerations of stress fractures of the foot and ankle. The imaging and clinical management of stress fractures of the foot and ankle are highly dependent on the specific location of the fracture, mechanical forces acting upon the injured site, vascular supply of the injured bone, and the proportion of trabecular to cortical bone at the site of injury. The most common stress fractures of the foot and ankle are low risk and include the posteromedial tibia, the calcaneus, and the second and third metatarsals. The distal fibula is a less common location, and stress fractures of the cuboid and cuneiforms are very rare, but are also considered low risk. In contrast, high-risk stress fractures are more prone to delayed union or nonunion and include the anterior tibial cortex, medial malleolus, navicular, base of the second metatarsal, proximal fifth metatarsal, hallux sesamoids, and the talus. Of these high-risk types, stress fractures of the anterior tibial cortex, the navicular, and the proximal tibial cortex may be predisposed to poor healing because of the watershed blood supply in these locations. The radiographic differential diagnosis of stress fracture includes osteoid osteoma, malignancy, and chronic osteomyelitis.

  20. Comprehensive profile of hip, knee and ankle ranges of motion in professional football players.

    Science.gov (United States)

    López-Valenciano, Alejandro; Ayala, Francisco; Vera-García, Francisco J; de Ste Croix, Mark; Hernández-Sánchez, Sergio; Ruiz-Pérez, Iñaki; Cejudo, Antonio; Santonja, Fernando

    2017-10-31

    Limited ranges of motion (ROM) have been considered as a primary risk factor for some football injuries, but only a few studies have analysed differences in lower extremity joints. The main purposes were (a) to describe the lower extremity ROM profile in professional football players; and (b) to examine differences between goalkeepers and outfield players. 82 professional male football players from 4 teams were measured in the 2013 pre-season. Measures of passive hip (flexion with knee flexed [PHFKF] and extended [PHFKE], extension [PHE], abduction [PHA], external [PHER] and internal [PHIR] rotation), knee (flexion [PKF]) and ankle (dorsiflexion with knee flexed [ADFKF] and extended [ADFKE]) ROMs were taken. Magnitude-based inferences exploring differences between player position and limb were made. 46% of all participants showed restricted PHFKE and/or around 30% showed restricted ADFKF ROM values. Contrarily, most players reported normal PHFKF, PHE, PHIR and PHER as well as PKF ROM scores with percentage values close to 100%. Bilateral meaningful differences for PHA, PHIR and PHER were found in approximately 30% of outfield players and goalkeepers. Statistical analysis found trivial differences between players for PHFKE, PHE, PHIR, PHER, ADFKE and ADFKF. However, moderate differences between players were found for PHFKF, PHA and PKF, with goalkeepers demonstrating higher values than outfield players. The findings of this study reinforce the necessity of prescribing exercises aimed at improving PHFKE and ADFKF ROM within everyday football training routines. In addition, as some bilateral deficits were observed, unilateral training should be considered where appropriate.

  1. A suggestion of reference data for flow distribution at ankle and foot level using quantitative 99Tc-HDP three-phase bone scintigraphy

    DEFF Research Database (Denmark)

    Tøndevold, Niklas; Reving, Sofie; Møller, Nette

    2012-01-01

    To determine reference intervals for quantitative 99mTc-hydroxymethylene diphosphonate (99mTc-HDP) three-phase bone scintigraphy regarding flow distribution at ankle and mid-foot level.......To determine reference intervals for quantitative 99mTc-hydroxymethylene diphosphonate (99mTc-HDP) three-phase bone scintigraphy regarding flow distribution at ankle and mid-foot level....

  2. Validation of the Dutch language version of the Foot and Ankle Outcome Score

    NARCIS (Netherlands)

    Sierevelt, I.N.; Beimers, L.; van Bergen, C.J.A.; Haverkamp, D.; Terwee, C.B.; Kerkhoffs, G.M.M.J.

    2015-01-01

    Purpose: The aim of this study was to develop a Dutch language version of the Foot and Ankle Outcome Score (FAOS-DLV) and evaluate its measurement properties according to the definitions of the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). Methods: After a

  3. Validation of the Dutch language version of the Foot and Ankle Outcome Score

    NARCIS (Netherlands)

    Sierevelt, I. N.; Beimers, L.; van Bergen, C. J. A.; Haverkamp, D.; Terwee, C. B.; Kerkhoffs, G. M. M. J.

    2015-01-01

    The aim of this study was to develop a Dutch language version of the Foot and Ankle Outcome Score (FAOS-DLV) and evaluate its measurement properties according to the definitions of the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). After a standard

  4. American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Score: a study protocol for the translation and validation of the Dutch language version.

    Science.gov (United States)

    Van Lieshout, Esther M M; De Boer, A Siebe; Meuffels, Duncan E; Den Hoed, P Ted; Van der Vlies, Cornelis H; Tuinebreijer, Wim E; Verhofstad, Michael H J

    2017-02-27

    The American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Score is among the most commonly used instruments for measuring the outcome of treatment in patients who sustained a complex ankle or hindfoot injury. It combines a clinician-reported and a patient-reported part. A valid Dutch version of this instrument is currently not available. Such a translated and validated instrument would allow objective comparison across hospitals or between patient groups, and with shown validity and reliability it may become a quality of care indicator in future. The main aims of this study are to translate and culturally adapt the AOFAS Ankle-Hindfoot Score questionnaire into Dutch according to international guidelines, and to evaluate the measurement properties of the AOFAS Ankle-Hindfoot Score-Dutch language version (DLV) in patients with a unilateral ankle or hindfoot fracture. The design of the study will be a multicentre prospective observational study (case series) in patients who presented to the emergency department with a unilateral ankle or hindfoot fracture or (fracture) dislocation. A research physician or research assistant will complete the AOFAS Ankle-Hindfoot Score-DLV based on interview for the subjective part and a physical examination for the objective part. In addition, patients will be asked to complete the Foot Function Index (FFI) and the Short Form-36 (SF-36). Descriptive statistics (including floor and ceiling effects), internal consistency, construct validity, reproducibility (ie, test-retest reliability, agreement and smallest detectable change) and responsiveness will be assessed for the AOFAS DLV. This study has been exempted by the Medical Research Ethics Committee (MREC) Erasmus MC (Rotterdam, the Netherlands). Each participant will provide written consent to participate and remain anonymised during the study. The results of the study are planned to be published in an international, peer-reviewed journal. NTR5613. pre-result. Published

  5. Extended ankle and foot fasciotomy as an enhancement to the surgical treatment of patients with prolonged ischemia of the lower extremities

    Directory of Open Access Journals (Sweden)

    Mišović Sidor

    2005-01-01

    Full Text Available Aim. To present the technique and efficacy of extended ankle and foot fasciotomy, as a surgical limb-salvage procedure associated with the successful revascularization after the gold interval. Method. A retrospective review of six patients at the age of 16−79 years (mean 39 in the period from 1996 to 2003, treated with the extended ankle and foot fasciotomy. There were four males undergoing the delayed treatment of war injuries to the lower extremity, and two females with atherosclerotic occlusive disease (a. illiacae dex and a. poplitealis dex.. The average ishemic time in the wounded patients was 22 hours (range, 14−30 hours, and ischemic time in occlusive disease (range, 48−72 hours. Clinical signs, indications, surgical access and the technique of extended ankle and foot fasciotomy was reported. Results. The obtained results were classified as early and late. There was no cases with lethal outcome. Incisional wounds closed 15 days after the intervention, using secondary suture or skin transplant sec. Thiersch. The satisfactory functional results were achieved in 4 of the patients, 1 had a small edema, while amputation was performed in 1 patient. Conclusion. In cases of prolonged foot ischemia with edema and paresthesia in the toes, extended ankle and foot fasciotomy should be performed as a surgical limb-salvage procedure.

  6. Validation of the Foot and Ankle Outcome Score in adult acquired flatfoot deformity.

    Science.gov (United States)

    Mani, Sriniwasan B; Brown, Haydée C; Nair, Pallavi; Chen, Lan; Do, Huong T; Lyman, Stephen; Deland, Jonathan T; Ellis, Scott J

    2013-08-01

    The American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Score has been under recent scrutiny. The Foot and Ankle Outcome Score (FAOS) is an alternative subjective survey, assessing outcomes in 5 subscales. It is validated for lateral ankle instability and hallux valgus patients. The aim of our study was to validate the FAOS for assessing outcomes in flexible adult acquired flatfoot deformity (AAFD). Patients from the authors' institution diagnosed with flexible AAFD from 2006 to 2011 were eligible for the study. In all, 126 patients who completed the FAOS and the Short-Form 12 (SF-12) on the same visit were included in the construct validity component. Correlation was deemed moderate if the Spearman's correlation coefficient was .4 to .7. Content validity was assessed in 63 patients by a questionnaire that asked patients to rate the relevance of each FAOS question, with a score of 2 or greater considered acceptable. Reliability was measured using intraclass correlation coefficients (ICCs) in 41 patients who completed a second FAOS survey. In 49 patients, preoperative and postoperative FAOS scores were compared to determine responsiveness. All of the FAOS subscales demonstrated moderate correlation with 2 physical health related SF-12 domains. Mental health related domains showed poor correlation. Content validity was high for the Quality of Life (QoL; mean 2.26) and Sports/Recreation subscales (mean 2.12). All subscales exhibited very good test-retest reliability, with ICCs of .7 and above. Symptoms, QoL, pain, and daily activities (ADLs) were responsive to change in postoperative patients (P validated the FAOS for AAFD with acceptable construct and content validity, reliability, and responsiveness. Given its previous validation for patients with ankle instability and hallux valgus, the additional findings in this study support its use as an alternative to less reliable outcome surveys. Level II, prospective comparative study.

  7. Effects of changing speed on knee and ankle joint load during walking and running.

    Science.gov (United States)

    de David, Ana Cristina; Carpes, Felipe Pivetta; Stefanyshyn, Darren

    2015-01-01

    Joint moments can be used as an indicator of joint loading and have potential application for sports performance and injury prevention. The effects of changing walking and running speeds on joint moments for the different planes of motion still are debatable. Here, we compared knee and ankle moments during walking and running at different speeds. Data were collected from 11 recreational male runners to determine knee and ankle joint moments during different conditions. Conditions include walking at a comfortable speed (self-selected pacing), fast walking (fastest speed possible), slow running (speed corresponding to 30% slower than running) and running (at 4 m · s(-1) ± 10%). A different joint moment pattern was observed between walking and running. We observed a general increase in joint load for sagittal and frontal planes as speed increased, while the effects of speed were not clear in the transverse plane moments. Although differences tend to be more pronounced when gait changed from walking to running, the peak moments, in general, increased when speed increased from comfortable walking to fast walking and from slow running to running mainly in the sagittal and frontal planes. Knee flexion moment was higher in walking than in running due to larger knee extension. Results suggest caution when recommending walking over running in an attempt to reduce knee joint loading. The different effects of speed increments during walking and running should be considered with regard to the prevention of injuries and for rehabilitation purposes.

  8. Evaluation of Peripheral Neuropathy of Unknown Origin in an Outpatient Foot and Ankle Practice.

    Science.gov (United States)

    Klein, Sandra E; Chu, Jennifer; McCormick, Jeremy J; Johnson, Jeffrey E

    2015-09-01

    The foot and ankle surgeon can see peripheral neuropathy in the treatment of foot and ankle conditions. The purpose of this study was (1) to evaluate the demographics and presenting complaints of patients diagnosed with idiopathic peripheral neuropathy during an examination by a foot and ankle surgeon and (2) to identify the type and frequency of subsequent diagnosis of medical causes of neuropathy. This was a retrospective study of patients diagnosed with idiopathic peripheral neuropathy in our practice between January 1997 and December 2008. Ninety-five patients were identified, and demographic data, presenting complaints, and medical comorbidities were extracted from the medical record. Examination findings of decreased sensation to Semmes Weinstein 5.07 monofilament testing were documented, and electromyogram and nerve conduction study results were reviewed when available. Laboratory values were noted, as were neurologic evaluations performed to diagnose medical conditions associated with peripheral neuropathy. The most common presentation was foot pain, in 36 patients (38%). Ninety-one patients had Semmes Weinstein 5.07 monofilament testing, with loss of protective sensation reported in 75 of the 91 tested (82%). Only 30 of the 95 patients had electromyogram and nerve conduction study results available, with a test positive for peripheral neuropathy in 20 of the 30 tested. Thirty-two patients were evaluated by a neurologist. A specific cause was identified in 12 of the 32 seen by a neurologist. Of the total group of 95 patients, 31 patients (33%) were diagnosed with a condition that may be associated with peripheral neuropathy. Thirty-three percent of the patients presenting to our clinic and given a diagnosis of idiopathic peripheral neuropathy were ultimately diagnosed with a medical cause of neuropathy-most commonly, diabetes. For those patients with idiopathic neuropathy, a spectrum of disease was encountered, including pain, ulcer, infection, and Charcot

  9. Relationship of body mass index, ankle dorsiflexion, and foot pronation on plantar fascia thickness in healthy, asymptomatic subjects.

    Science.gov (United States)

    Pascual Huerta, Javier; García, Juan Maria Alarcón; Matamoros, Eva Cosin; Matamoros, Julia Cosin; Martínez, Teresa Díaz

    2008-01-01

    We sought to investigate the thickness of plantar fascia, measured by means of ultrasonographic evaluation in healthy, asymptomatic subjects, and its relationship to body mass index, ankle joint dorsiflexion range of motion, and foot pronation in static stance. One hundred two feet of 51 healthy volunteers were examined. Sonographic evaluation with a 10-MHz linear array transducer was performed 1 and 2 cm distal to its insertion. Physical examination was also performed to assess body mass index, ankle joint dorsiflexion, and degree of foot pronation in static stance. Both examinations were performed in a blinded manner. Body mass index showed moderate correlation with plantar fascia thickness at the 1- and 2-cm locations. Ankle dorsiflexion range of motion showed no correlation at either location. Foot pronation showed an inverse correlation with plantar fascia thickness at the 2-cm location and no correlation at the 1-cm location. Body mass index and foot supination at the subtalar joint are related to increased thickness at the plantar fascia in healthy, asymptomatic subjects. Although the changes in thickness were small compared with those in patients with symptomatic plantar fasciitis, they could play a role in the mechanical properties of plantar fascia and in the development of plantar fasciitis.

  10. Stress fractures about the tibia, foot, and ankle.

    Science.gov (United States)

    Shindle, Michael K; Endo, Yoshimi; Warren, Russell F; Lane, Joseph M; Helfet, David L; Schwartz, Elliott N; Ellis, Scott J

    2012-03-01

    In competitive athletes, stress fractures of the tibia, foot, and ankle are common and lead to considerable delay in return to play. Factors such as bone vascularity, training regimen, and equipment can increase the risk of stress fracture. Management is based on the fracture site. In some athletes, metabolic workup and medication are warranted. High-risk fractures, including those of the anterior tibial diaphysis, navicular, proximal fifth metatarsal, and medial malleolus, present management challenges and may require surgery, especially in high-level athletes who need to return to play quickly. Noninvasive treatment modalities such as pulsed ultrasound and extracorporeal shock wave therapy may have some benefit but require additional research.

  11. Nondestructive evaluation of reinforced plastics by a radiometric measurement technique

    International Nuclear Information System (INIS)

    Entine, Gerald; Afshari, Sia; Verlinden, Matt

    1990-01-01

    The demand for new high-performance plastics has greatly increased with advances in the performance characteristics of sophisticated reinforced engineering resins. However, conventional methods for the evaluation of the glass and filler contents of reinforced plastics are destructive, labor intensive, and time consuming. We have developed a new instrument, to address this problem, which provides for the rapid, accurate, and nondestructive measurement of glass or filler content in reinforced plastics. This instrument utilizes radiation transmission and scattering techniques for analytical measurement of glass, graphite and other fillers used in reinforced plastics. (author)

  12. Evaluation of the Dutch version of the Foot and Ankle Outcome Score (FAOS): Responsiveness and Minimally Important Change

    NARCIS (Netherlands)

    Sierevelt, I. N.; van Eekeren, I. C. M.; Haverkamp, D.; Reilingh, M. L.; Terwee, C. B.; Kerkhoffs, G. M. M. J.

    2016-01-01

    The aim of this study was to evaluate the responsiveness of the Foot and Ankle Outcome Score (FAOS) and provide data on the Minimally Important Change (MIC) in patients 1 year after hindfoot and ankle surgery. Prospective pre-operative and 1 year post-operative FAOS scores were collected from 145

  13. Reverse peroneal artery flap for large defects of ankle and foot: A reliable reconstructive technique

    Directory of Open Access Journals (Sweden)

    Jose Tharayil

    2012-01-01

    Full Text Available Background: Large soft tissue defects around the lower third of the leg, ankle and foot always have been challenging to reconstruct. Reverse sural flaps have been used for this problem with variable success. Free tissue transfer has revolutionised management of these problem wounds in selected cases. Materials and Methods: Twenty-two patients with large defects around the lower third of the leg, ankle and foot underwent reconstruction with reverse peroneal artery flap (RPAF over a period of 7 years. The mean age of these patients was 41.2 years. Results: Of the 22 flaps, 21 showed complete survival without even marginal necrosis. One flap failed, where atherosclerotic occlusion of peroneal artery was evident on the table. Few patients had minor donor site problems that settled with conservative management. Conclusions: RPAF is a very reliable flap for the coverage of large soft tissue defects of the heel, sole and dorsum of foot. This flap adds versatility in planning and execution of this extended reverse sural flap.

  14. Ankle-foot orthosis bending axis influences running mechanics.

    Science.gov (United States)

    Russell Esposito, Elizabeth; Ranz, Ellyn C; Schmidtbauer, Kelly A; Neptune, Richard R; Wilken, Jason M

    2017-07-01

    Passive-dynamic ankle-foot orthoses (AFOs) are commonly prescribed to improve locomotion for people with lower limb musculoskeletal weakness. The clinical prescription and design process are typically qualitative and based on observational assessment and experience. Prior work examining the effect of AFO design characteristics generally excludes higher impact activities such as running, providing clinicians and researchers limited information to guide the development of objective prescription guidelines. The proximal location of the bending axis may directly influence energy storage and return and resulting running mechanics. The purpose of this study was to determine if the location of an AFO's bending axis influences running mechanics. Marker and force data were recorded as 12 participants with lower extremity weakness ran overground while wearing a passive-dynamic AFO with posterior struts manufactured with central (middle) and off-centered (high and low) bending axes. Lower extremity joint angles, moments, powers, and ground reaction forces were calculated and compared between limbs and across bending axis conditions. Bending axis produced relatively small but significant changes. Ankle range of motion increased as the bending axis shifted distally (pbenefits during running, although individual preference and physical ability should also be considered. Published by Elsevier B.V.

  15. Foot Health Facts for Athletes

    Science.gov (United States)

    ... common foot problems affecting athletes: Prevent Foot & Ankle Running Injuries (downloadable PDF) Back-to-School Soccer Season Surgeons ... and Ankle Soccer is hard on the feet! Injuries to the foot and ankle can occur from running and side-to-side cutting, sliding or tackling ...

  16. [Carbon fiber-reinforced plastics as implant materials].

    Science.gov (United States)

    Bader, R; Steinhauser, E; Rechl, H; Siebels, W; Mittelmeier, W; Gradinger, R

    2003-01-01

    Carbon fiber-reinforced plastics have been used clinically as an implant material for different applications for over 20 years.A review of technical basics of the composite materials (carbon fibers and matrix systems), fields of application,advantages (e.g., postoperative visualization without distortion in computed and magnetic resonance tomography), and disadvantages with use as an implant material is given. The question of the biocompatibility of carbon fiber-reinforced plastics is discussed on the basis of experimental and clinical studies. Selected implant systems made of carbon composite materials for treatments in orthopedic surgery such as joint replacement, tumor surgery, and spinal operations are presented and assessed. Present applications for carbon fiber reinforced plastics are seen in the field of spinal surgery, both as cages for interbody fusion and vertebral body replacement.

  17. Effects of plantar fascia stiffness on the biomechanical responses of the ankle-foot complex.

    Science.gov (United States)

    Cheung, Jason Tak-Man; Zhang, Ming; An, Kai-Nan

    2004-10-01

    The plantar fascia is one of the major stabilizing structures of the longitudinal arch of human foot, especially during midstance of the gait cycle. Knowledge of its functional biomechanics is important for establishing the biomechanical rationale behind different rehabilitation, orthotic and surgical treatment of plantar fasciitis. This study aims at quantifying the biomechanical responses of the ankle-foot complex with different plantar fascia stiffness. A geometrical detailed three-dimensional finite element model of the human foot and ankle, incorporating geometric and contact nonlinearities was constructed by 3D reconstruction of MR images. A sensitivity study was conducted to evaluate the effects of varying elastic modulus (0-700 MPa) of the plantar fascia on the stress/strain distribution of the bony, ligamentous and encapsulated soft tissue structures. The results showed that decreasing the Young's modulus of plantar fascia would increase the strains of the long and short plantar and spring ligaments significantly. With zero fascia Young's modulus to simulate the plantar fascia release, there was a shift in peak von Mises stresses from the third to the second metatarsal bones and increased stresses at the plantar ligament attachment area of the cuboid bone. Decrease in arch height and midfoot pronation were predicted but did not lead to the total collapse of foot arch. Surgical dissection of the plantar fascia may induce excessive strains or stresses in the ligamentous and bony structures. Surgical release of plantar fascia should be well-planned to minimise the effect on its structural integrity to reduce the risk of developing arch instability and subsequent painful foot syndrome.

  18. Gender differences of sagittal knee and ankle biomechanics during stair-to-ground descent transition.

    Science.gov (United States)

    Hong, Yoon No Gregory; Shin, Choongsoo S

    2015-12-01

    Falls on stairs often result in severe injury and occur twice as frequently in women. However, gender differences in kinetics and kinematics during stair descent are unknown. Thus, this study aimed to determine whether gender differences of knee and ankle biomechanics exist in the sagittal plane during the stair-to-ground descending transition. It was hypothesized that 1) women would reveal higher ground-toe-trochanter angle and lower ground-toe length during stair-to-ground descent transition than men; and 2) women would reveal lower peak knee extension moment during stair-to-ground descent transition than men. Fifteen men and fifteen women were recruited and performed a stair descent activity. Kinetic and kinematic data were obtained using a force plate and motion capture system. The women performed the stair descent with a lower peak knee extension moment and a peak knee power at the early weight acceptance phase. The women also revealed a higher ground-toe-trochanter angle and a lower ground-toe length, which indicated a more forward position of the lower extremity relative to the toe contact point at both the initial contact and at the time of peak kinematic and kinetic events. This study found that knee and ankle kinematics and kinetics differed significantly between the genders due to differences in ground-toe-trochanter angle. Women have a different stair descending strategy that reduces the demand of the lower extremity muscle function, but this strategy seems to increase the risk of falls. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Cyclic settlement behavior of strip footings resting on reinforced layered sand slope

    Directory of Open Access Journals (Sweden)

    Mostafa A. El Sawwaf

    2012-10-01

    Full Text Available The paper presents a study of the behavior of model strip footings supported on a loose sandy slope and subjected to both monotonic and cyclic loads. The effects of the partial replacement of a compacted sand layer and the inclusion of geosynthetic reinforcement were investigated. Different combinations of the initial monotonic loads and the amplitude of cyclic loads were chosen to simulate structures in which loads change cyclically such as machine foundations. The affecting factors including the location of footing relative to the slope crest, the frequency of the cyclic load and the number of load cycles were studied. The cumulative cyclic settlement of the model footing supported on a loose sandy slope, un-reinforced and reinforced replaced sand deposits overlying the loose slope were obtained and compared. Test results indicate that the inclusion of soil reinforcement in the replaced sand not only significantly increases the stability of the sandy slope itself but also decreases much both the monotonic and cumulative cyclic settlements leading to an economic design of the footings. However, the efficiency of the sand–geogrid systems depends on the properties of the cyclic load and the location of the footing relative to the slope crest. Based on the test results, the variation of cumulative settlements with different parameters is presented and discussed.

  20. Footwear recommendations and patterns among orthopaedic foot and ankle surgeons: a survey.

    Science.gov (United States)

    Farber, Daniel C; Knutsen, Elisa J

    2013-12-01

    Foot and ankle surgeons are in a unique position to educate patients about the importance of proper footwear. Neither their recommendations regarding shoe selection nor their own footwear patterns have previously been reported. A total of 866 members of the American Orthopaedic Foot & Ankle Society (AOFAS) were asked to complete a survey via the Internet. Topics included specific shoe brands recommended to patients, how attributes of footwear are communicated, and respondents' footwear habits. In all, 276 (32%) surgeons responded, and 64% recommended New Balance athletic shoes to patients; 26% did not recommend specific brands. It was found that 50% wear New Balance athletic shoes; 25% wear Nike. Rockport (27%) and SAS (27%) were the most recommended dress shoes. In all, 76% are familiar with AOFAS guidelines for proper shoe fit, but only 56% educated their patients about the guidelines; 43% do not consider what patients might think of their shoes when selecting what to wear in the clinical setting. Despite the multitude of different brands, several were commonly recommended. Respondents seem to be aware of the impact of their own shoe selection on patients' perspectives of footwear, but many do not consider themselves role models for proper footwear.

  1. Application of ankle joint adem position combined with foot inclined position in ankle sprain%踝关节正侧位联合足正斜位在足踝扭伤中的应用

    Institute of Scientific and Technical Information of China (English)

    施付强; 胡扬; 刘霞; 汪伟伟

    2015-01-01

    Objective To investigate X-ray examination technique and diagnosis of ankle joint sprain, in order to reduce misdiagnosis rate. Methods There were 8 patients with fractures caused by ankle joint sprain, and they all received ankle joint adem position examination and foot inclined position examination. Examination results were observed. Results Among the 8 patients, there was 1 case with lateral malleolus fracture, whose ankle joint adem position result was worse than foot inclined position, 1 case with lateral malleolus fracture, which was not showed by ankle joint adem position but was clearly showed by foot inclined position, and 1 case with fracture in basilar part of the fifth metatarsal bone, which had ankle joint adem position results better than foot inclined position. Conclusion Application of ankle joint adem position combined with foot inclined position examination can show the fracture line better than single examination by joint adem position or foot inclined position, thereby the coincidence rate of diagnosis can be improved.%目的:探讨踝关节扭伤的X线检查技术及诊断,以降低误诊漏诊率。方法8例足踝扭伤并致骨折的患者,均行踝关节正侧位检查及足正斜位检查,观察检查结果。结果8例患者中,有1例外踝骨折,踝关节正侧位显示不如足正斜位,1例外踝骨折踝关节正侧位未能显示,而足正斜位能清晰显示,1例第五跖骨基底部骨折足正斜位显示不如踝关节正侧位。结论踝关节扭伤患者行踝关节正侧位联合足正斜位检查比单纯踝关节正侧位检查或单纯足正斜位检查能更好的显示骨折线,从而提高诊断符合率。

  2. Validation of the Italian version of the Oxford Ankle Foot Questionnaire for children.

    Science.gov (United States)

    Martinelli, Nicolò; Romeo, Giovanni; Bonifacini, Carlo; Viganò, Marco; Bianchi, Alberto; Malerba, Francesco

    2016-01-01

    The purpose of this study was to translate the Oxford Ankle Foot Questionnaire (OAFQ) into Italian, to perform a cross-cultural adaptation and to evaluate its psychometric properties. The Italian OAFQ was developed according to the recommended forward/backward translation protocol and evaluated in pediatric patients treated for symptomatic flatfoot deformity. Feasibility, reliability, internal consistency, construct validity [comparing OAFQ domains with Child Health Questionnaire (CHQ) domains] and responsiveness to surgical treatment were assessed. A total of 61 children and their parents were enrolled in the study. Results showed satisfactory levels of internal consistency for both children and parent forms. The test-retest reliability was confirmed by high ICC values for both child and parents subscales. Good construct validity was showed by patterns of relationships consistent with theoretically related domains of the CHQ. After surgery, the mean OAFQ scores improved in all the domains after treatment with the subtalar arthroereisis, for both children and parent scales (p valid instrument in order to evaluate interventions used to treat children's foot or ankle problem, but needs further study on different clinical settings.

  3. Flowtron foot-pumps for prevention of venous thromboembolism in total hip and knee replacement.

    Science.gov (United States)

    Pitto, Rocco P; Koh, Chuan K

    2015-03-01

    Mechanical prophylaxis with foot-pumps provides an interesting alternative to chemical agents in the prevention of venous thomboembolism following major orthopaedic surgery procedures. The aim of this prospective study was to assess efficacy and safety of the Flowtron(®) foot-pumps system following total hip and knee replacement. The foot pumps were used as main tool for prevention of thromboembolic events, in most cases in association with a variety of chemicals. The primary endpoint of the study was to assess the incidence of deep vein thrombosis and pulmonary embolism after total hip and knee replacement. The secondary endpoints included postoperative bleeding, swelling, bruising and wound ooze. 424 consecutive patients were included in the study. Symptomatic deep vein thrombosis was detected in 7 patients (1.6%). All symptomatic deep vein thromboses were detected after discharge before the six week follow-up clinic. Five non-fatal pulmonary embolisms occurred (1.2%). Only one patient presented a major wound bleeding (0.2%). The mean difference of swelling of thigh pre-versus postoperatively was only 22.8 mm. In conclusion, thromboembolism prophylaxis after total hip and knee replacement using Flowtron(®) foot-pumps as main prevention tool of an individualised protocol appears effective and safe. This is the first clinical report related to this popular brand of foot pumps.

  4. The Cosmic-ray Spectrum: from the knee to the ankle

    International Nuclear Information System (INIS)

    Gaisser, T K

    2006-01-01

    This talk addresses the question, 'Where is the transition from cosmic rays of galactic origin to extra-galactic cosmic-rays?' I have addressed the background of this topic recently in lectures at Erice and, with Todor Stanev, in a collection of papers on various aspects of nuclear astrophysics. Here I concentrate on primary composition as a signature of the transition and mention some new air-shower experiments aimed at the energy region from the knee to the ankle (PeV to 10 EeV)

  5. Behavior of a strip footing on reinforced soil subjected to inclined load

    Directory of Open Access Journals (Sweden)

    Abbas Jawdat

    2018-01-01

    Full Text Available This study investigates the behavior of a strip footing under inclined load on reinforced sandy soil by using experimental model. The effect of the load inclination angle (α, number of geogrid layers (N and the relative density (RD on the bearing capacity, settlement and horizontal displacement were studied. The results showed that by increasing the number of reinforcement layers (N, the bearing capacity increased, but there is an optimum value (N=4-5 depending on relative density of supporting soil. Also the settlement and horizontal displacement of footing decreasing with increase number of reinforcement layers.

  6. Development and validation of a computational model to study the effect of foot constraint on ankle injury due to external rotation.

    Science.gov (United States)

    Wei, Feng; Hunley, Stanley C; Powell, John W; Haut, Roger C

    2011-02-01

    Recent studies, using two different manners of foot constraint, potted and taped, document altered failure characteristics in the human cadaver ankle under controlled external rotation of the foot. The posterior talofibular ligament (PTaFL) was commonly injured when the foot was constrained in potting material, while the frequency of deltoid ligament injury was higher for the taped foot. In this study an existing multibody computational modeling approach was validated to include the influence of foot constraint, determine the kinematics of the joint under external foot rotation, and consequently obtain strains in various ligaments. It was hypothesized that the location of ankle injury due to excessive levels of external foot rotation is a function of foot constraint. The results from this model simulation supported this hypothesis and helped to explain the mechanisms of injury in the cadaver experiments. An excessive external foot rotation might generate a PTaFL injury for a rigid foot constraint, and an anterior deltoid ligament injury for a pliant foot constraint. The computational models may be further developed and modified to simulate the human response for different shoe designs, as well as on various athletic shoe-surface interfaces, so as to provide a computational basis for optimizing athletic performance with minimal injury risk.

  7. Evaluation of the validity of the Foot Function Index in measuring outcomes in patients with foot and ankle disorders.

    Science.gov (United States)

    SooHoo, Nelson F; Samimi, David B; Vyas, Raj M; Botzler, Tin

    2006-01-01

    There is uncertainty regarding which outcomes tools should be used to report the results of treatment for patients with foot and ankle disorders. This study evaluates the validity of the Foot Function Index (FFI) by examining its level of correlation to the Medical Outcomes Study Short Form-36 (SF-36). The SF-36 is an extensively validated outcomes tool that has been used as a benchmark in examining the validity of several orthopaedic outcomes tools. Seventy-three patients were recruited at a tertiary referral foot and ankle practice. Patients completed packets which included informed consent forms, the FFI, and the SF-36 questionnaires. The questionnaires were scored and Pearson correlation coefficients were determined between the three domains of the FFI and the eight SF-36 sub-scales, as well as the two SF-36 summary scales. Sixty-nine patients completed an adequate number of items to be included in the study. The mean age of the patient sample was 46 (range 16 to 82) years and 44 were women (64%). Twenty-one patients (30%) had conditions affecting the forefoot, while 48 patients (70%) had conditions affecting the ankle or hindfoot. All three FFI domains had moderate to high levels of correlation to many of the SF-36 scales. The Disability domain of the FFI had the most consistent level of correlation to the SF-36 with Pearson coefficients in the range of -0.23 to -0.69. The Activity Limitation (r=-0.28 to -0.64) and Pain domains (r=-0.10 to -0.61) also demonstrated moderate levels of correlation to several of the SF-36 scales. The consistently moderate to high levels of correlation of the FFI to the SF-36 seen in this study support the FFI as a valid measure of health status. This suggests that the FFI is a reasonable method to monitor patient outcomes. Future studies should focus on determining if the FFI improves responsiveness to clinical change when used in combination with generic instruments like the SF-36.

  8. Proprioception of foot and ankle complex in young regular practitioners of ice hockey, ballet dancing and running.

    Science.gov (United States)

    Li, Jing Xian; Xu, Dong Qing; Hoshizaki, Blaine

    2009-01-01

    This study examined the proprioception of the foot and ankle complex in regular ice hockey practitioners, runners, and ballet dancers. A total of 45 young people with different exercise habits formed four groups: the ice hockey, ballet dancing, running, and sedentary groups. Kinesthesia of the foot and ankle complex was measured in plantarflexion (PF), dorsiflexion (DF), inversion (IV), and eversion (EV) at 0.4 degrees /s using a custom-made device. The results showed the following: (1) significantly better perceived passive motion sense in PF/DF was found as compared with the measurements in IV/EV within each group (P ballet groups perceived significantly better passive motion sense in IV/EV than the running (P ballet dancing on proprioception may be associated with their movement characteristics.

  9. Strength and thermal stability of fiber reinforced plastic composites ...

    African Journals Online (AJOL)

    Therefore, the strength properties and thermal stability of plastic composites reinforced with rattan fibers were investigated in this work. Particles of rattan species (Eremospatha macrocarpa (EM) and Laccosperma secundiflorum (LS)) were blended with High-Density Polyethylene (HDPE) to produce fiber reinforced plastic ...

  10. Impact of Foot Type on Cost of Lower Extremity Injury

    Science.gov (United States)

    2013-01-25

    were at higher risk for injury. Additionally, researchers have found relationships between chronic heel pain and osteoarthritis of the knee and hip...Cost of Injury, in Physical Training and Sports Injury Prevention Guidelines . 2010, U.S. Army Public Health Command (Provisional). 11. Injury...study. BMC Musculoskelet Disord, 2007. 8: p. 41. 48. Reilly, K., et al., The role of foot and ankle assessment of patients with lower limb osteoarthritis

  11. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    Science.gov (United States)

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  12. Combining valgus knee brace and lateral foot wedges reduces external forces and moments in osteoarthritis patients

    NARCIS (Netherlands)

    Jafarnezhadgero, Amir Ali; Oliveira, Anderson S.; Mousavi, Seyed Hamed; Madadi-Shad, Morteza

    Osteoarthritis progression can be related to the external knee adduction and flexion moments during walking. Lateral foot wedges and knee braces have been used as treatment for osteoarthritis, but little is known about their influence on knee joint moments generated in the sagittal and frontal

  13. An open 8-channel parallel transmission coil for static and dynamic 7T MRI of the knee and ankle joints at multiple postures.

    Science.gov (United States)

    Jin, Jin; Weber, Ewald; Destruel, Aurelien; O'Brien, Kieran; Henin, Bassem; Engstrom, Craig; Crozier, Stuart

    2018-03-01

    We present the initial in vivo imaging results of an open architecture eight-channel parallel transmission (pTx) transceive radiofrequency (RF) coil array that was designed and constructed for static and dynamic 7T MRI of the knee and ankle joints. The pTx coil has a U-shaped dual-row configuration (200 mm overall length longitudinally) that allows static and dynamic imaging of the knee and ankle joints at various postures and during active movements. This coil structure, in combination with B 1 shimming, allows flexible configuration of B 1 transmit profiles, with good homogeneity over 120-mm regions of interest. This coil enabled high-resolution gradient echo (e.g., 3D dual-echo steady state [DESS] and 3D multiecho data image combination [MEDIC]) and turbo spin echo (TSE) imaging (e.g., with proton density weighting [PDw], PDw with fat saturation, and T 1 and T 2 weightings) with local RF energy absorption rates well below regulatory limits. High-resolution 2D and 3D image series (e.g., 0.3 mm in-plane resolution for TSE, 0.47 mm isotropic for DESS and MEDIC) were obtained from the knee and ankle joints with excellent tissue contrast. Dynamic imaging during continuous knee and ankle flexion-extension cycles were successfully acquired. The new open pTx coil array provides versatility for high-quality static and dynamic MRI of the knee and ankle joints at 7T. Magn Reson Med 79:1804-1816, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Kinematic features of rear-foot motion using anterior and posterior ankle-foot orthoses in stroke patients with hemiplegic gait.

    Science.gov (United States)

    Chen, Chih-Chi; Hong, Wei-Hsien; Wang, Chin-Man; Chen, Chih-Kuang; Wu, Katie Pei-Hsuan; Kang, Chao-Fu; Tang, Simon F

    2010-12-01

    To evaluate the kinematic features of rear-foot motion during gait in hemiplegic stroke patients, using anterior ankle-foot orthoses (AFOs), posterior AFOs, and no orthotic assistance. Crossover design with randomization for the interventions. A rehabilitation center for adults with neurologic disorders. Patients with hemiplegia due to stroke (n=14) and able-bodied subjects (n=11). Subjects with hemiplegia were measured walking under 3 conditions with randomized sequences: (1) with an anterior AFO, (2) with a posterior AFO, and (3) without an AFO. Control subjects were measured walking without an AFO to provide a normative reference. Rear-foot kinematic change in the sagittal, coronal, and transverse planes. In the sagittal plane, compared with walking with an anterior AFO or without an AFO, the posterior AFO significantly decreased plantar flexion to neutral at initial heel contact (P=.001) and the swing phase (PRehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Machining of Fibre Reinforced Plastic Composite Materials

    Science.gov (United States)

    2018-01-01

    Fibre reinforced plastic composite materials are difficult to machine because of the anisotropy and inhomogeneity characterizing their microstructure and the abrasiveness of their reinforcement components. During machining, very rapid cutting tool wear development is experienced, and surface integrity damage is often produced in the machined parts. An accurate selection of the proper tool and machining conditions is therefore required, taking into account that the phenomena responsible for material removal in cutting of fibre reinforced plastic composite materials are fundamentally different from those of conventional metals and their alloys. To date, composite materials are increasingly used in several manufacturing sectors, such as the aerospace and automotive industry, and several research efforts have been spent to improve their machining processes. In the present review, the key issues that are concerning the machining of fibre reinforced plastic composite materials are discussed with reference to the main recent research works in the field, while considering both conventional and unconventional machining processes and reporting the more recent research achievements. For the different machining processes, the main results characterizing the recent research works and the trends for process developments are presented. PMID:29562635

  16. Machining of Fibre Reinforced Plastic Composite Materials

    Directory of Open Access Journals (Sweden)

    Alessandra Caggiano

    2018-03-01

    Full Text Available Fibre reinforced plastic composite materials are difficult to machine because of the anisotropy and inhomogeneity characterizing their microstructure and the abrasiveness of their reinforcement components. During machining, very rapid cutting tool wear development is experienced, and surface integrity damage is often produced in the machined parts. An accurate selection of the proper tool and machining conditions is therefore required, taking into account that the phenomena responsible for material removal in cutting of fibre reinforced plastic composite materials are fundamentally different from those of conventional metals and their alloys. To date, composite materials are increasingly used in several manufacturing sectors, such as the aerospace and automotive industry, and several research efforts have been spent to improve their machining processes. In the present review, the key issues that are concerning the machining of fibre reinforced plastic composite materials are discussed with reference to the main recent research works in the field, while considering both conventional and unconventional machining processes and reporting the more recent research achievements. For the different machining processes, the main results characterizing the recent research works and the trends for process developments are presented.

  17. Strain gradient plasticity effects in whisker-reinforced metals

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof

    2002-01-01

    A metal reinforced by fibers in the micron range is studied using the strain gradient plasticity theory of Fleck and Hutchinson (2001). Cell-model analyzes are used to study the influence of the material length parameters numerically. Different higher order boundary conditions are considered...... at the fiber-matrix interface. The results are presented as overall stress-strain curves for the whisker-reinforced metal, and also contour plots of effective plastic strain are shown. The strain gradient plasticity theory predicts a significant stiffening effect when compared to conventional models...

  18. Ankle-foot orthoses that restrict dorsiflexion improve walking in polio survivors with calf muscle weakness

    NARCIS (Netherlands)

    Ploeger, Hilde E.; Bus, Sicco A.; Brehm, Merel-Anne; Nollet, Frans

    2014-01-01

    In polio survivors with calf muscle weakness, dorsiflexion-restricting ankle-foot orthoses (DR-AFOs) aim to improve gait in order to reduce walking-related problems such as instability or increased energy cost. However, evidence on the efficacy of DR-AFOs in polio survivors is lacking. We

  19. Foot and ankle compression improves joint position sense but not bipedal stance in older people

    NARCIS (Netherlands)

    Hijmans, J.M.; Zijlstra, W.; Geertzen, J.H.; Hof, A.L.; Postema, K.

    This study investigates the effects of foot and ankle compression on joint position sense (JPS) and balance in older people and young adults. 12 independently living healthy older persons (77-93 years) were recruited from a senior accommodation facility. 15 young adults (19-24 years) also

  20. The clinical assessment study of the foot (CASF: study protocol for a prospective observational study of foot pain and foot osteoarthritis in the general population

    Directory of Open Access Journals (Sweden)

    Menz Hylton B

    2011-09-01

    Full Text Available Abstract Background Symptomatic osteoarthritis (OA affects approximately 10% of adults aged over 60 years. The foot joint complex is commonly affected by OA, yet there is relatively little research into OA of the foot, compared with other frequently affected sites such as the knee and hand. Existing epidemiological studies of foot OA have focussed predominantly on the first metatarsophalangeal joint at the expense of other joints. This three-year prospective population-based observational cohort study will describe the prevalence of symptomatic radiographic foot OA, relate its occurrence to symptoms, examination findings and life-style-factors, describe the natural history of foot OA, and examine how it presents to, and is diagnosed and managed in primary care. Methods All adults aged 50 years and over registered with four general practices in North Staffordshire, UK, will be invited to participate in a postal Health Survey questionnaire. Respondents to the questionnaire who indicate that they have experienced foot pain in the preceding twelve months will be invited to attend a research clinic for a detailed clinical assessment. This assessment will consist of: clinical interview; physical examination; digital photography of both feet and ankles; plain x-rays of both feet, ankles and hands; ultrasound examination of the plantar fascia; anthropometric measurement; and a further self-complete questionnaire. Follow-up will be undertaken in consenting participants by postal questionnaire at 18 months (clinic attenders only and three years (clinic attenders and survey participants, and also by review of medical records. Discussion This three-year prospective epidemiological study will combine survey data, comprehensive clinical, x-ray and ultrasound assessment, and review of primary care records to identify radiographic phenotypes of foot OA in a population of community-dwelling older adults, and describe their impact on symptoms, function and

  1. Effect of kinesiotaping, non-elastic taping and bracing on segmental foot kinematics during drop landing in healthy subjects and subjects with chronic ankle instability.

    Science.gov (United States)

    Kuni, B; Mussler, J; Kalkum, E; Schmitt, H; Wolf, S I

    2016-09-01

    To evaluate the effects of kinesiotape, non-elastic tape, and soft brace on segmental foot kinematics during drop landing in subjects with chronic ankle instability and healthy subjects. Controlled study with repeated measurements. Three-dimensional motion analysis laboratory. Twenty participants with chronic ankle instability and 20 healthy subjects. The subjects performed drop landings with 17 retroreflective markers on the foot and lower leg in four conditions: barefoot, with kinesiotape, with non-elastic tape and with a soft brace. Ranges of motion of foot segments using a foot measurement method. In participants with chronic ankle instability, midfoot movement in the frontal plane (inclination of the medial arch) was reduced significantly by non-elastic taping, but kinesiotaping and bracing had no effect. In healthy subjects, both non-elastic taping and bracing reduced that movement. In both groups, non-elastic taping and bracing reduced rearfoot excursion in inversion/eversion significantly, which indicates a stabilisation effect. No such effect was found with kinesiotaping. All three methods reduced maximum plantar flexion significantly. Non-elastic taping stabilised the midfoot best in patients with chronic ankle instability, while kinesiotaping did not influence foot kinematics other than to stabilise the rearfoot in the sagittal plane. ClinicalTrials.gov NCT01810471. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  2. Adaptive sports ankle prosthetics. Interview by Sarah A. Curran.

    Science.gov (United States)

    Lyle, David K

    2012-09-01

    Participating in sport at all levels is gaining a dedicated following and this is also apparent in individuals with an amputation. Currently, there is a wide variety of ankle prostheses available which attempt to provide function, control, and comfort, as well as good aesthetic appeal. Participation in sport, however, increases the demands placed upon ankle prostheses. This can compromise function and performance, and constrain the opportunities of participation in various outdoor and water sports. In acknowledging this limitation and the need to develop more versatile ankle prostheses, this article introduces the evolution of a prototype ankle prosthesis referred to as "Adaptive Sports Ankle." The ankle prosthesis, which is compatible with any foot pyramid adapter, offers the same range of motion as the normal human ankle joint and is made up of components that are chemical and corrosion resistant. These design features that are specifically created to accommodate below-the-knee amputees provide an ideal prosthesis for those wishing to lead an active lifestyle and participate in aquatic (i.e. swimming, surfing, and scuba diving), snowboarding, and equestrian activities. Although it is acknowledged that there is a need to establish research on the Adaptive Sports Ankle, its introduction to the market will enhance and expand opportunities of those individuals with a lower limb amputation to lead an active and healthy lifestyle.

  3. Full text publication rates of papers presented at the British Foot and Ankle Society.

    Science.gov (United States)

    Marsland, D; Mumith, A; Taylor, H P

    2017-07-13

    Techniques in foot and ankle surgery have expanded rapidly in recent years, often presented at national society meetings. It is important that research is published to guide evidence based practice. Many abstracts however do not go on to full text publication. A database was created of all abstracts presented at BOFAS meetings from 2009 to 2013. Computerised searches were performed using PubMed and Google search engines. In total 341 papers were presented, with an overall publication rate of 31.7%. Of 251 clinical papers, 200 were case series (79.6%). Factors associated with publication success included basic science studies, papers related to arthroscopic surgery and research performed outside the UK. A relatively low conversion rate from presentation to publication could be as a result of papers failing to pass the scrutiny of peer review, or that the work is never formally submitted for publication. The information from this study could be used to prioritise future research and promote higher quality research. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  4. The extrinsic influence of carbon fibre reinforced plastic laminates to ...

    Indian Academy of Sciences (India)

    The extrinsic influence of carbon fibre reinforced plastic laminates to strengthen steel structures ... The intrinsic advantages of strengthening the steel-based structures by the use of fibre reinforced plastic (FRP) material have ... Sadhana | News.

  5. Translation, cross-cultural adaption and validation of the German version of the Foot and Ankle Ability Measure for patients with chronic ankle instability.

    Science.gov (United States)

    Nauck, T; Lohrer, H

    2011-08-01

    The evaluation of health-related quality of life and physical function is important for determining therapeutic strategies following ankle injuries. The Anglo-American Foot and Ankle Ability Measure (FAAM) is a valid and reliable self-reported measure to detect functional deficits in chronic lateral ankle instability. The purpose of this study was to translate, cross-culturally adapt and validate the FAAM questionnaire for use with German-speaking patients with chronic lateral ankle instability. Preoperative and conservatively treated patients with chronic lateral ankle instability. Sport students and volleyball athletes served as control groups. The FAAM was forward and back translated, cross-culturally adapted and validated. The study population completed the FAAM-G questionnaire twice within 3-5 days. Additionally, the patients were scored with the Good ankle laxity classification system. Test-Retest reliability, construct validity and internal consistency were calculated. Reliability and validity of the FAAM-G were examined in presurgical chronic ankle instability patients (n=24), conservatively treated chronic ankle instability patients (n=17), university sport students (n=31) and volleyballers (n=37). Test-retest reliability revealed fair, good, or excellent reliability (inter-class correlation coefficient (ICC)=0.590-0.998; ρ=0.528-1.000). Construct validity, tested between the FAAM-G subscores and the Good et al ankle laxity classification system demonstrated strong correlations (ρ = -0.819 to -0.861). The original FAAM questionnaire was successfully translated and cross-culturally adapted from English to German. Corresponding to the Anglo-American version, the FAAM-G is a reliable and valid questionnaire for self-reported assessment of pain and disability in German-speaking patients suffering from chronic ankle instability.

  6. Postural Control Characteristics during Single Leg Standing of Individuals with a History of Ankle Sprain: Measurements Obtained Using a Gravicorder and Head and Foot Accelerometry.

    Science.gov (United States)

    Abe, Yota; Sugaya, Tomoaki; Sakamoto, Masaaki

    2014-03-01

    [Purpose] This study aimed to validate the postural control characteristics of individuals with a history of ankle sprain during single leg standing by using a gravicorder and head and foot accelerometry. [Subjects] Twenty subjects with and 23 subjects without a history of ankle sprain (sprain and control groups, respectively) participated. [Methods] The anteroposterior, mediolateral, and total path lengths, as well as root mean square (RMS) of each length, were calculated using the gravicorder. The anteroposterior, mediolateral, and resultant acceleration of the head and foot were measured using accelerometers and were evaluated as the ratio of the acceleration of the head to the foot. [Results] There was no significant difference between the two groups in path length or RMS acceleration of the head and foot. However, the ratios of the mediolateral and resultant components were significantly higher in the sprain group than in the control group. [Conclusion] Our findings suggest that individuals with a history of ankle sprain have a higher head-to-foot acceleration ratio and different postural control characteristics than those of control subjects.

  7. Progress in the clinical imaging research of bone diseases on ankle and foot sesamoid bones and accessory ossicles

    Science.gov (United States)

    Li, Xiaozhong; Shi, Lenian; Liu, Taiyun; Wang, Lin

    2012-01-01

    Summary Sesamoid bones and accessory ossicles are research focuses of foot and ankle surgery. Pains of the foot and ankle are related to sesamoid bones and accessory ossicles. The specific anatomical and functional relationship of sesamoid bones and accessory ossicles can cause such bone diseases as the dislocation of sesamoid bones and accessory bones, infection, inflammation and necrosis of sesamoid bones, cartilage softening, tenosynovitis of sesamoid bones and the sesamoid bone syndrome. However, these bone diseases are often misdiagnosed or mistreated. In patients with trauma history, relevant diseases of sesamoid bones and accessory ossicles as above mentioned are highly probable to be misdiagnosed as avulsion fractures. In such cases, radiographic findings may provide a basis for clinical diagnosis. PMID:25343083

  8. Risk of hip fracture after osteoporosis fractures. 451 women with fracture of lumbar spine, olecranon, knee or ankle

    DEFF Research Database (Denmark)

    Lauritzen, J B; Lund, B

    1993-01-01

    In a follow-up study during 1976-1984, the risk of a subsequent hip fracture was investigated in women aged 60-99 years, hospitalized for the following fractures: lumbar spine (n 70), olecranon (n 52), knee (n 129) and ankle (n 200). Follow-up ranged from 0 to 9 years. Observation time of the 4...... different fractures were 241, 180, 469, and 779, person-years, respectively. In women aged 60-79 years with one of the following fractures the relative risk of a subsequent hip fracture was increased by 4.8 (lumbar spine), 4.1 (olecranon), 3.5 (knee) and 1.5 (ankle). The relative risk of hip fracture showed...... a tendency to level off 3 years after the primary fracture....

  9. Correction of tibial malunion in a patient with ipsilateral total knee and ankle prostheses using external ring fixation and the ilizarov method

    Directory of Open Access Journals (Sweden)

    Alexander M Smith

    2017-01-01

    Full Text Available Total ankle replacement (TAR aims at reestablishing a functional and painless ankle joint while maintaining motion and preventing adjacent joint arthritis. TAR can be complicated by comorbidities such as ipsilateral knee arthritis and deformity with subsequent arthroplasty and/or other lower extremity malalignment issues. We present a case of a 67-year-old female with severe right ankle pain and a history of ipsilateral subtalar and calcaneocuboid fusion, bilateral total knee arthroplasty, and a malunion of a conservatively treated ipsilateral segmental tibial fracture. Following TAR, there was recurrent lateral hindfoot pain due to subtle malalignment from the tibial malunion which resulted in persistent hindfoot valgus. This caused symptomatic subfibular impingement in addition to limb length discrepancy. To address that, a circular external fixator was applied to realign the ankle and lengthen the tibia, eliminating pain and avoiding complications with either implant.

  10. Mechanical supports for acute, severe ankle sprain: a pragmatic, multicentre, randomised controlled trial.

    Science.gov (United States)

    Lamb, S E; Marsh, J L; Hutton, J L; Nakash, R; Cooke, M W

    2009-02-14

    Severe ankle sprains are a common presentation in emergency departments in the UK. We aimed to assess the effectiveness of three different mechanical supports (Aircast brace, Bledsoe boot, or 10-day below-knee cast) compared with that of a double-layer tubular compression bandage in promoting recovery after severe ankle sprains. We did a pragmatic, multicentre randomised trial with blinded assessment of outcome. 584 participants with severe ankle sprain were recruited between April, 2003, and July, 2005, from eight emergency departments across the UK. Participants were provided with a mechanical support within the first 3 days of attendance by a trained health-care professional, and given advice on reducing swelling and pain. Functional outcomes were measured over 9 months. The primary outcome was quality of ankle function at 3 months, measured using the Foot and Ankle Score; analysis was by intention to treat. This study is registered as an International Standard Randomised Controlled Trial, number ISRCTN37807450. Patients who received the below-knee cast had a more rapid recovery than those given the tubular compression bandage. We noted clinically important benefits at 3 months in quality of ankle function with the cast compared with tubular compression bandage (mean difference 9%; 95% CI 2.4-15.0), as well as in pain, symptoms, and activity. The mean difference in quality of ankle function between Aircast brace and tubular compression bandage was 8%; 95% CI 1.8-14.2, but there were little differences for pain, symptoms, and activity. Bledsoe boots offered no benefit over tubular compression bandage, which was the least effective treatment throughout the recovery period. There were no significant differences between tubular compression bandage and the other treatments at 9 months. Side-effects were rare with no discernible differences between treatments. Reported events (all treatments combined) were cellulitis (two cases), pulmonary embolus (two cases), and

  11. Inter-assessor reliability of practice based biomechanical assessment of the foot and ankle

    Directory of Open Access Journals (Sweden)

    Jarvis Hannah L

    2012-06-01

    Full Text Available Abstract Background There is no consensus on which protocols should be used to assess foot and lower limb biomechanics in clinical practice. The reliability of many assessments has been questioned by previous research. The aim of this investigation was to (i identify (through consensus what biomechanical examinations are used in clinical practice and (ii evaluate the inter-assessor reliability of some of these examinations. Methods Part1: Using a modified Delphi technique 12 podiatrists derived consensus on the biomechanical examinations used in clinical practice. Part 2: Eleven podiatrists assessed 6 participants using a subset of the assessment protocol derived in Part 1. Examinations were compared between assessors. Results Clinicians choose to estimate rather than quantitatively measure foot position and motion. Poor inter-assessor reliability was recorded for all examinations. Intra-class correlation coefficient values (ICC for relaxed calcaneal stance position were less than 0.23 and were less than 0.14 for neutral calcaneal stance position. For the examination of ankle joint dorsiflexion, ICC values suggest moderate reliability (less than 0.61. The results of a random effects ANOVA highlight that participant (up to 5.7°, assessor (up to 5.8° and random (up to 5.7° error all contribute to the total error (up to 9.5° for relaxed calcaneal stance position, up to 10.7° for the examination of ankle joint dorsiflexion. Kappa Fleiss values for categorisation of first ray position and mobility were less than 0.05 and for limb length assessment less than 0.02, indicating slight agreement. Conclusion Static biomechanical assessment of the foot, leg and lower limb is an important protocol in clinical practice, but the key examinations used to make inferences about dynamic foot function and to determine orthotic prescription are unreliable.

  12. The health economics of ankle and foot sprains and fractures: A systematic review of English-language published papers. Part 2: The direct and indirect costs of injury.

    Science.gov (United States)

    Bielska, Iwona A; Wang, Xiang; Lee, Raymond; Johnson, Ana P

    2017-07-20

    Ankle and foot sprains and fractures are prevalent injuries, which may result in substantial physical and economic consequences for the patient and place a financial burden on the health care system. Therefore, the objectives of this paper are to examine the direct and indirect costs of treating ankle and foot injuries (sprains, dislocations, fractures), as well as to provide an overview of the outcomes of full economic analyses of different treatment strategies. A systematic review was carried out among seven databases to identify English language publications on the health economics of ankle and foot injury treatment published between 1980 and 2014. The direct and indirect costs were abstracted by two independent reviewers. All costs were adjusted for inflation and reported in 2016 US dollars (USD). Among 2047 identified studies, 32 were selected for analysis. The direct costs of ankle sprain management ranged from $292 to $2268 per patient (2016 USD), depending on the injury severity and treatment strategy. The direct costs of managing ankle fractures were higher ($1908-$19,555). Foot fracture treatment had similar direct costs ranging from $998 to $21,801. The economic evaluations were conducted from the societal or payer's perspectives. The costs of treating ankle and foot sprains and fractures varied among the studies, mostly due to differences in injury type and study characteristics, which impacted the ability of directly comparing the financial burden of treatment. Nonetheless, the review showed that the costs experienced by the patient and the health care system increased with injury complexity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Experience using the «Shetty test» for initial foot and ankle fracture screening in the Emergency Department.

    Science.gov (United States)

    Ojeda-Jiménez, J; Méndez-Ojeda, M M; Martín-Vélez, P; Tejero-García, S; Pais-Brito, J L; Herrera-Pérez, M

    2018-03-20

    The indiscriminate practice of radiographs for foot and ankle injuries is not justified and numerous studies have corroborated the usefulness of clinical screening tests such as the Ottawa Ankle Rules. The aim of our study is to clinically validate the so-called Shetty Test in our area. A cross-sectional observational study by applying the Shetty test to patients seen in the Emergency Department. We enrolled 100 patients with an average age of 39.25 (16-86). The Shetty test was positive on 14 occasions. Subsequent radiography revealed a fracture in 10 cases: 4 were false positives. The test was negative in the remaining 86 patients and radiography confirmed the absence of fracture (with sensitivity of 100% and specificity of 95.56%, positive predictive value of 71.40%, and negative predictive value of 100%). The Shetty test is a valid clinical screening tool to decide whether simple radiography is indicated for foot and ankle injuries. It is a simple, quick and reproducible test. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Enhancing performance during inclined loaded walking with a powered ankle-foot exoskeleton.

    Science.gov (United States)

    Galle, Samuel; Malcolm, Philippe; Derave, Wim; De Clercq, Dirk

    2014-11-01

    A simple ankle-foot exoskeleton that assists plantarflexion during push-off can reduce the metabolic power during walking. This suggests that walking performance during a maximal incremental exercise could be improved with an exoskeleton if the exoskeleton is still efficient during maximal exercise intensities. Therefore, we quantified the walking performance during a maximal incremental exercise test with a powered and unpowered exoskeleton: uphill walking with progressively higher weights. Nine female subjects performed two incremental exercise tests with an exoskeleton: 1 day with (powered condition) and another day without (unpowered condition) plantarflexion assistance. Subjects walked on an inclined treadmill (15%) at 5 km h(-1) and 5% of body weight was added every 3 min until exhaustion. At volitional termination no significant differences were found between the powered and unpowered condition for blood lactate concentration (respectively, 7.93 ± 2.49; 8.14 ± 2.24 mmol L(-1)), heart rate (respectively, 190.00 ± 6.50; 191.78 ± 6.50 bpm), Borg score (respectively, 18.57 ± 0.79; 18.93 ± 0.73) and VO₂ peak (respectively, 40.55 ± 2.78; 40.55 ± 3.05 ml min(-1) kg(-1)). Thus, subjects were able to reach the same (near) maximal effort in both conditions. However, subjects continued the exercise test longer in the powered condition and carried 7.07 ± 3.34 kg more weight because of the assistance of the exoskeleton. Our results show that plantarflexion assistance during push-off can increase walking performance during a maximal exercise test as subjects were able to carry more weight. This emphasizes the importance of acting on the ankle joint in assistive devices and the potential of simple ankle-foot exoskeletons for reducing metabolic power and increasing weight carrying capability, even during maximal intensities.

  15. Knee and ankle osteoarthritis in former elite soccer players: A systematic review of the recent literature

    NARCIS (Netherlands)

    Kuijt, Marie-Therese K.; Inklaar, Han; Gouttebarge, Vincent; Frings-Dresen, Monique H. W.

    2012-01-01

    Objectives: To investigate the prevalence of knee and/or ankle osteoarthritis in former elite soccer player. Design: Systematic review. Methods: Medline, Embase and SPORTDiscus (2000 to January 2012) were used. To be included, studies were required to be a primary study, written in English, Dutch,

  16. A review on the mechanical design elements of ankle rehabilitation robot.

    Science.gov (United States)

    Khalid, Yusuf M; Gouwanda, Darwin; Parasuraman, Subramanian

    2015-06-01

    Ankle rehabilitation robots are developed to enhance ankle strength, flexibility and proprioception after injury and to promote motor learning and ankle plasticity in patients with drop foot. This article reviews the design elements that have been incorporated into the existing robots, for example, backdrivability, safety measures and type of actuation. It also discusses numerous challenges faced by engineers in designing this robot, including robot stability and its dynamic characteristics, universal evaluation criteria to assess end-user comfort, safety and training performance and the scientific basis on the optimal rehabilitation strategies to improve ankle condition. This article can serve as a reference to design robot with better stability and dynamic characteristics and good safety measures against internal and external events. It can also serve as a guideline for the engineers to report their designs and findings. © IMechE 2015.

  17. Mitek Anchor System: a new technique for tenodesis and ligamentous repair of the foot and ankle.

    Science.gov (United States)

    Pederson, B; Tesoro, D; Wertheimer, S J; Coraci, M

    1991-01-01

    The authors present an alternative method for securing tendon and ligaments to bone, utilizing the Mitek Anchor System. The description of the Mitek system and technique of application is presented. Technical simplicity and ease of adaptability within the foot and ankle are distinct advantages of this System.

  18. Tradução e validação do questionário FAOS - FOOT and ankle outcome score para língua portuguesa Translation, cultural adaptation and validation of FOOT and ankle outcome score (FAOS questionnaire into portuguese

    Directory of Open Access Journals (Sweden)

    Aline Mizusaki Imoto

    2009-01-01

    Full Text Available OBJETIVOS: (1 traduzir e validar a versão original da avaliação funcional de tornozelo e pé Foot and Ankle Outcome Score (FAOS da língua inglesa para a portuguesa em pacientes com história de entorse de tornozelo em inversão, (2 adaptar culturalmente à população brasileira e (3 correlacionar com o questionário de qualidade de vida SF-36. MÉTODO: O método de tradução e validação utilizado seguiu os critérios descritos por Guillemin et al. Foram incluídos 50 indivíduos com diagnóstico clínico de lesão ligamentar lateral do tornozelo por entorse. RESULTADOS: O questionário FAOS mostrou-se com reprodutibilidade de grau forte para todos os domínios intra e inter-examinador (pOBJECTIVE: (1 to translate and validate the original version of the Foot and Ankle Outcome Score (FAOS questionnaire from English into Portuguese in patients with diagnosis of lateral ligament injuries with ankle sprain history,(2 to provide cultural adaptation for Brazilian patients (3 to correlate it with the quality of life SF_36 questionnaire. METHOD: The method of translation and validation followed the criteria described by Guillemin et al. Fifty patients with ankle sprain were included. RESULTS AND CONCLUSION: FAOS questionnaire showed good reproducibility for patients with ankle sprain and good reliability for all intraand inter-interviewer sub-scales (p<0.05. The translation and cultural adaptation of FAOS questionnaire had its properties of assessment, reliability and validity measured, showing that this questionnaire is suitable for use in Brazilian patients with lateral ligament ankle injuries.

  19. Is there any relationship between orthotic usage and functional activities in children with neuromuscular disorders?

    Science.gov (United States)

    Alemdaroğlu, İpek; Gür, Gozde; Bek, Nilgün; Yilmaz, Öznur T; Yakut, Yavuz; Uygur, Fatma; Karaduman, Ayşe

    2014-02-01

    Contractures of Achilles tendons and gastrocnemius muscle deteriorate the performance in daily living activities of patients with neuromuscular diseases. Ankle-foot orthoses help to prevent the progression of deformities and to obtain optimal position of the joints to support standing and walking. To investigate the relationship between orthotic usage and functional activities in pediatric patients with different neuromuscular diseases. Retrospective study. A total of 127 subjects' physical assessment forms were analyzed. Functional level, type of orthoses, falling frequencies, ankle joint range of motion, and timed performance tests were examined in two consecutive dates with an interval of 3 months. A total of 91 patients were using orthoses while 36 patients were not within assessment dates. A total of 64 of 91 (70.3%) patients were diagnosed with Duchenne muscular dystrophy. A total of 81 (89.0%) subjects were using plastic ankle-foot orthoses for positioning at nights and 10 (11%) were using different types of the orthoses (knee-ankle-foot orthoses, dynamic ankle-foot orthoses, and so on) for gait in the study group. Night ankle-foot orthoses were not found to be effective directly on functional performance in children with neuromuscular diseases, although they protect ankle from contractures and may help to correct gait and balance. This retrospective study shows that the positive effects of using an ankle-foot orthosis at night are not reflected in the functional performance of children with neuromuscular diseases. This may be due to the progressive deteriorating nature of the disease.

  20. Chronic Ankle Instability

    Science.gov (United States)

    ... top of the talus is dome-shaped and... Softball Injuries to the Foot and Ankle Your feet ... ankles take a beating when you are playing softball. Softball players should be aware of the following ...

  1. Association between hip abductor function, rear-foot dynamic alignment, and dynamic knee valgus during single-leg squats and drop landings

    Directory of Open Access Journals (Sweden)

    Yoshinori Kagaya

    2015-06-01

    Conclusion: Dynamic hip mal-alignment might be associated with both greater KID and HOD, whereas rear-foot eversion is associated only with greater KID. Hip abductor and rear-foot dysfunction are important factors for dynamic knee valgus and thus evaluating DTT and HFT will help to prevent dynamic knee valgus.

  2. The role of series ankle elasticity in bipedal walking.

    Science.gov (United States)

    Zelik, Karl E; Huang, Tzu-Wei P; Adamczyk, Peter G; Kuo, Arthur D

    2014-04-07

    The elastic stretch-shortening cycle of the Achilles tendon during walking can reduce the active work demands on the plantarflexor muscles in series. However, this does not explain why or when this ankle work, whether by muscle or tendon, needs to be performed during gait. We therefore employ a simple bipedal walking model to investigate how ankle work and series elasticity impact economical locomotion. Our model shows that ankle elasticity can use passive dynamics to aid push-off late in single support, redirecting the body's center-of-mass (COM) motion upward. An appropriately timed, elastic push-off helps to reduce dissipative collision losses at contralateral heelstrike, and therefore the positive work needed to offset those losses and power steady walking. Thus, the model demonstrates how elastic ankle work can reduce the total energetic demands of walking, including work required from more proximal knee and hip muscles. We found that the key requirement for using ankle elasticity to achieve economical gait is the proper ratio of ankle stiffness to foot length. Optimal combination of these parameters ensures proper timing of elastic energy release prior to contralateral heelstrike, and sufficient energy storage to redirect the COM velocity. In fact, there exist parameter combinations that theoretically yield collision-free walking, thus requiring zero active work, albeit with relatively high ankle torques. Ankle elasticity also allows the hip to power economical walking by contributing indirectly to push-off. Whether walking is powered by the ankle or hip, ankle elasticity may aid walking economy by reducing collision losses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Effect of reinforcement on plastic limit loads of branch junctions

    International Nuclear Information System (INIS)

    Kim, Yun-Jae; Myeong, Man-Sik; Yoon, Kee-Bong

    2009-01-01

    This paper provides effects of reinforcement shape and area on plastic limit loads of branch junctions under internal pressure and in-plane/out-of-plane bending, via detailed three-dimensional finite element limit analysis assuming elastic-perfectly plastic material behaviour. It is found that reinforcement is most effective when (in-plane/out-of-plane) bending is applied to the branch pipe. When bending is applied to the run pipe, reinforcement is less effective when bending is applied to the branch pipe. The reinforcement effect is the least effective for internal pressure.

  4. Analytical, Numerical and Experimental Examination of Reinforced Composites Beams Covered with Carbon Fiber Reinforced Plastic

    Science.gov (United States)

    Kasimzade, A. A.; Tuhta, S.

    2012-03-01

    In the article, analytical, numerical (Finite Element Method) and experimental investigation results of beam that was strengthened with fiber reinforced plastic-FRP composite has been given as comparative, the effect of FRP wrapping number to the maximum load and moment capacity has been evaluated depending on this results. Carbon FRP qualitative dependences have been occurred between wrapping number and beam load and moment capacity for repair-strengthen the reinforced concrete beams with carbon fiber. Shown possibilities of application traditional known analysis programs, for the analysis of Carbon Fiber Reinforced Plastic (CFRP) strengthened structures.

  5. Reliability and smallest real difference of the ankle lunge test post ankle fracture.

    Science.gov (United States)

    Simondson, David; Brock, Kim; Cotton, Susan

    2012-02-01

    This study aimed to determine the reliability and the smallest real difference of the Ankle Lunge test in an ankle fracture patient population. In the post immobilisation stage of ankle fracture, ankle dorsiflexion is an important measure of progress and outcome. The Ankle Lunge test measures weight bearing dorsiflexion, resulting in negative scores (knee to wall distance) and positive scores (toe to wall distance), for which the latter has proven reliability in normal subjects only. A consecutive sample of ankle fracture patients with permission to commence weight bearing, were recruited to the study. Three measurements of the Ankle Lunge Test were performed each by two raters, one senior and one junior physiotherapist. These occurred prior to therapy sessions in the second week after plaster removal. A standardised testing station was utilised and allowed for both knee to wall distance and toe to wall distance measurement. Data was collected from 10 individuals with ankle fracture, with an average age of 36 years (SD 14.8). Seventy seven percent of observations were negative. Intra and inter-rater reliability yielded intra class correlations at or above 0.97, p Ankle Lunge test is a practical and reliable tool for measuring weightbearing dorsiflexion post ankle fracture. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Effects of spinal cord injury-induced changes in muscle activation on foot drag in a computational rat ankle model.

    Science.gov (United States)

    Hillen, Brian K; Jindrich, Devin L; Abbas, James J; Yamaguchi, Gary T; Jung, Ranu

    2015-04-01

    Spinal cord injury (SCI) can lead to changes in muscle activation patterns and atrophy of affected muscles. Moderate levels of SCI are typically associated with foot drag during the swing phase of locomotion. Foot drag is often used to assess locomotor recovery, but the causes remain unclear. We hypothesized that foot drag results from inappropriate muscle coordination preventing flexion at the stance-to-swing transition. To test this hypothesis and to assess the relative contributions of neural and muscular changes on foot drag, we developed a two-dimensional, one degree of freedom ankle musculoskeletal model with gastrocnemius and tibialis anterior muscles. Anatomical data collected from sham-injured and incomplete SCI (iSCI) female Long-Evans rats as well as physiological data from the literature were used to implement an open-loop muscle dynamics model. Muscle insertion point motion was calculated with imposed ankle trajectories from kinematic analysis of treadmill walking in sham-injured and iSCI animals. Relative gastrocnemius deactivation and tibialis anterior activation onset times were varied within physiologically relevant ranges based on simplified locomotor electromyogram profiles. No-atrophy and moderate muscle atrophy as well as normal and injured muscle activation profiles were also simulated. Positive moments coinciding with the transition from stance to swing phase were defined as foot swing and negative moments as foot drag. Whereas decreases in activation delay caused by delayed gastrocnemius deactivation promote foot drag, all other changes associated with iSCI facilitate foot swing. Our results suggest that even small changes in the ability to precisely deactivate the gastrocnemius could result in foot drag after iSCI. Copyright © 2015 the American Physiological Society.

  7. The effects of powered ankle-foot orthoses on joint kinematics and muscle activation during walking in individuals with incomplete spinal cord injury

    Directory of Open Access Journals (Sweden)

    Domingo Antoinette

    2006-02-01

    Full Text Available Abstract Background Powered lower limb orthoses could reduce therapist labor during gait rehabilitation after neurological injury. However, it is not clear how patients respond to powered assistance during stepping. Patients might allow the orthoses to drive the movement pattern and reduce their muscle activation. The goal of this study was to test the effects of robotic assistance in subjects with incomplete spinal cord injury using pneumatically powered ankle-foot orthoses. Methods Five individuals with chronic incomplete spinal cord injury (ASIA C-D participated in the study. Each subject was fitted with bilateral ankle-foot orthoses equipped with artificial pneumatic muscles to power ankle plantar flexion. Subjects walked on a treadmill with partial bodyweight support at four speeds (0.36, 0.54, 0.72 and 0.89 m/s under three conditions: without wearing orthoses, wearing orthoses unpowered (passively, and wearing orthoses activated under pushbutton control by a physical therapist. Subjects also attempted a fourth condition wearing orthoses activated under pushbutton control by them. We measured joint angles, electromyography, and orthoses torque assistance. Results A therapist quickly learned to activate the artificial pneumatic muscles using the pushbuttons with the appropriate amplitude and timing. The powered orthoses provided ~50% of peak ankle torque. Ankle angle at stance push-off increased when subjects walked with powered orthoses versus when they walked with passive-orthoses (ANOVA, p Two of the five subjects were able to control the orthoses themselves using the pushbuttons. The other three subjects found it too difficult to coordinate pushbutton timing. Orthoses assistance and maximum ankle angle at push-off were smaller when the subject controlled the orthoses compared to when the therapist-controlled the orthoses (p Conclusion Mechanical assistance from powered ankle-foot orthoses improved ankle push-off kinematics without

  8. Direct measurement of the intrinsic ankle stiffness during standing.

    Science.gov (United States)

    Vlutters, M; Boonstra, T A; Schouten, A C; van der Kooij, H

    2015-05-01

    Ankle stiffness contributes to standing balance, counteracting the destabilizing effect of gravity. The ankle stiffness together with the compliance between the foot and the support surface make up the ankle-foot stiffness, which is relevant to quiet standing. The contribution of the intrinsic ankle-foot stiffness to balance, and the ankle-foot stiffness amplitude dependency remain a topic of debate in the literature. We therefore developed an experimental protocol to directly measure the bilateral intrinsic ankle-foot stiffness during standing balance, and determine its amplitude dependency. By applying fast (40 ms) ramp-and-hold support surface rotations (0.005-0.08 rad) during standing, reflexive contributions could be excluded, and the amplitude dependency of the intrinsic ankle-foot stiffness was investigated. Results showed that reflexive activity could not have biased the torque used for estimating the intrinsic stiffness. Furthermore, subjects required less recovery action to restore balance after bilateral rotations in opposite directions compared to rotations in the same direction. The intrinsic ankle-foot stiffness appears insufficient to ensure balance, ranging from 0.93±0.09 to 0.44±0.06 (normalized to critical stiffness 'mgh'). This implies that changes in muscle activation are required to maintain balance. The non-linear stiffness decrease with increasing rotation amplitude supports the previous published research. With the proposed method reflexive effects can be ruled out from the measured torque without any model assumptions, allowing direct estimation of intrinsic stiffness during standing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. The Influence of Mulligan Ankle Taping on Dynamic Balance in the Athletes with and without Chronic Ankle Instability

    Directory of Open Access Journals (Sweden)

    Tahereh Pourkhani

    2014-04-01

    Full Text Available Objective: The ankle joint is the most frequently injured anatomical site in athletes. Ankle instability is responsible for 25% of all time lost from sport. Clinical efficacy of the effect of taping in athletes with chronic ankle instability is unknown. So the purpose of this investigation is the study of the influence of Mulligan ankle taping on dynamic balance in the athletes with and without chronic ankle instability. Materials & Methods: 32 athletes participated in this investigation: 16 subjects with chronic ankle instability, 6 women and 10 men (age 23.5±0.3 years, height 175.4±10.3 cm, weight 73.6±14.5 kg, Foot Ankle Disability Index 74.5±8.62% and Foot Ankle Disability Index Sport 63.5±7.86% and 16 healthy subjects, 6 women and 10 men (age 22.81±7.1 years, height 173.6±12.26 cm, weight 66.4±11.4 kg, Foot Ankle Disability Index and Foot Ankle Disability Index Sport 100%. Dynamic balance was assessed with Star Excursion Balance Test in 3 reaching directions (medial, antero-medial and postero-medial before and after Mulligan ankle taping. Independent and paired t-test were used for statistical analysis. Results: Dynamic balance in healthy group significantly was better than injured group (P&le0.05. Application of taping caused significantly improvement in dynamic balance in both groups (reaching in media, antero-medial and postero-medial directions (P&le0.05 (except reaching in antero-medial direction in healthy group (P>0.05. Conclusion: So it seems that Mulligan ankle taping can improve dynamic balance in the athletes with and without chronic ankle instability.

  10. Sprained Ankles

    Science.gov (United States)

    ... away before the ligament is injured. Types of Sprains In young children, the ankle is the most commonly sprained joint, followed by ... A walking cast may be necessary if the ankle or foot injury has been severe. Most grade 1 sprains will heal within two weeks without subsequent complications. ...

  11. Poor compliance with ankle-foot-orthoses in Charcot-Marie-Tooth disease.

    Science.gov (United States)

    Vinci, P; Gargiulo, P

    2008-03-01

    The aim of this study is to evaluate the compliance with ankle-foot orthoses (AFOs) in patients previously prescribed and affected with Charcot-Marie-Tooth disease (CMT). Twenty-five Italian patients (8 males 17 females; mean age: 41.6 years, range 16-54) with severe bilateral footdrop (leg-sole angle alpha >105 degrees ) alone or associated with other problems (rotation, plantarflexor failure, knee flexor failure) were examined by a physiatrist (with measurement of the leg-sole angle alpha' with their footwear) and interviewed by a psychologist. Only 5 patients (20%) used AFOs (3 prefabricated polypropylene AFOs, 2 custom-made short AFOs incorporated in high-top boots) with satisfactory functional results (alpha' <=94 degrees ; reported increased mobility and no more falls). The interview revealed that all patients had a bad relationship with their own body. The 3 subjects using prefabricated AFOs said that they hated them and one of them complained of pain. Patients not using AFOs justified their decision with statements such as: ''I am not yet ready to accept them'' (n=3) or ''I can still manage without them for a while'' (n=2) or both (n=15). Four patients had experienced pain during the trial, 2 had not found proper shoes to accommodate them and 12 were absolutely not interested in AFOs and, therefore, had not gone to an orthotist. Compliance with AFOs is poor. Patients with CMT discard AFOs because they highlight their disability, are not essential for their limited daily walking and are uncomfortable. We suggest that prescription of AFOs be accompanied with psychological support and that research of more comfortable and cosmetically acceptable solutions for the problem of footdrop be stimulated.

  12. Plastic ingestion by Flesh-footed Shearwaters (Puffinus carneipes): Implications for fledgling body condition and the accumulation of plastic-derived chemicals

    International Nuclear Information System (INIS)

    Lavers, Jennifer L.; Bond, Alexander L.; Hutton, Ian

    2014-01-01

    To provide much needed quantitative data on the lethal and sublethal effects of plastic pollution on marine wildlife, we sampled breast feathers and stomach contents from Flesh-footed Shearwater (Puffinus carneipes) fledglings in eastern Australia. Birds with high levels of ingested plastic exhibited reduced body condition and increased contaminant load (p < 0.05). More than 60% of fledglings exceed international targets for plastic ingestion by seabirds, with 16% of fledglings failing these targets after a single feeding (range: 0.13–3.21 g of plastic/feeding). As top predators, seabirds are considered sentinels of the marine environment. The amount of plastic ingested and corresponding damage to Flesh-footed Shearwater fledglings is the highest reported for any marine vertebrate, suggesting the condition of the Australian marine environment is poor. These findings help explain the ongoing decline of this species and are worrying in light of increasing levels of plastic pollution in our oceans. - Highlights: • Proportion of the shearwater population ingesting plastic increased over four years. • Shearwater body condition is negatively influenced by the amount of ingested plastic. • Shearwater contaminant load is positively related to the amount of ingested plastic. • Many chicks exceed international targets for ingested plastic after a single feeding. • Plastic ingestion in this study is the highest reported for any marine vertebrate. - Flesh-footed Shearwaters ingest large quantities of marine plastic, which is correlated with poor body condition and increased concentrations of trace metals such as chromium

  13. Direct measurement of the intrinsic ankle stiffness during standing

    NARCIS (Netherlands)

    Vlutters, Mark; Vlutters, M.; Boonstra, Tjitske; Schouten, Alfred Christiaan; van der Kooij, Herman

    2015-01-01

    Ankle stiffness contributes to standing balance, counteracting the destabilizing effect of gravity. The ankle stiffness together with the compliance between the foot and the support surface make up the ankle-foot stiffness, which is relevant to quiet standing. The contribution of the intrinsic

  14. Shock absorption of below-knee prostheses : A comparison between the SACH and the Multiflex foot

    NARCIS (Netherlands)

    van Leeuwen, J. L.; Speth, L. A W M; Daanen, H. A M

    1990-01-01

    Shock waves were measured during walking on a treadmill on the metal tube of a below-knee KBM prosthesis, provided either with a SACH foot or with a Multiflex foot. Accelerations were measured in the axial direction and the dorso-ventral direction, about 160 mm proximal to the sole of the shoe. The

  15. The Effect of Foot Progression Angle on Knee Joint Compression Force during Walking

    DEFF Research Database (Denmark)

    Baldvinsson, Henrik Koblauch; Heilskov-Hansen, Thomas; Alkjær, Tine

    2013-01-01

    males walked at a fixed speed of 4.5 km/h under three conditions: Normal walking, internally rotated and externally rotated. All gait-trials were recorded by six infrared cameras. Net joint moments were calculated by 3D inverse dynamics. The results revealed that the medial knee joint compartment......It is unclear how rotations of the lower limb affect the knee joint compression forces during walking. Increases in the frontal plane knee moment have been reported when walking with internally rotated feet and a decrease when walking with externally rotated feet. The aim of this study...... was to investigate the knee joint compressive forces during walking with internal, external and normal foot rotation and to determine if the frontal plane knee joint moment is an adequate surrogate for the compression forces in the medial and lateral knee joint compartments under such gait modifications. Ten healthy...

  16. Numerical modelling of reinforced concrete beams with fracture-plastic material

    Directory of Open Access Journals (Sweden)

    O. Sucharda

    2014-10-01

    Full Text Available This paper describes the use of models of fracture-plastic materials for reinforced concrete in numerical modelling of beams made from reinforced concrete. The purpose of the paper is to use of a model of concrete for modelling of a behaviour of reinforced concrete beams which have been tested at the University of Toronto within re-examination of classic concrete beam tests. The original tests were performed by Bresler- Scordelis. A stochastic modelling based on LHS (Latin Hypercube Sampling has been performed for the reinforced concrete beam. An objective of the modelling is to evaluate the total bearing capacity of the reinforced concrete beams depending on distribution of input data. The beams from the studied set have longitudinal reinforcement only. The beams do not have any shear reinforcement. The software used for the fracture-plastic model of the reinforced concrete is the ATENA.

  17. Correlation between knee and hindfoot alignment in patients with rheumatoid arthritis: The effects of subtalar joint destruction.

    Science.gov (United States)

    Nakada, Izumi; Nakamura, Ichiro; Juji, Takuo; Ito, Katsumi; Matsumoto, Takumi

    2015-09-01

    Compensatory hindfoot alignment for deformities at the knee level has been demonstrated in patients with knee osteoarthritis. However, this phenomenon has not been elucidated in patients with rheumatoid arthritis (RA). The aim of this study is to investigate the relationship between knee deformity and hindfoot alignment and the effect of subtalar joint destruction in patients with RA. We retrospectively investigated RA patients (110 patients, 205 limbs) using radiographs in the standing anteroposterior knee, standing lateral foot, and hindfoot alignment views. The grade of destruction at the knee and subtalar joints was assigned using Larsen's grading system. The correlation between the femorotibial and tibiocalcaneal angles and the effect of joint destruction on this correlation were analyzed using Pearson's correlation coefficients. There was moderate correlation between the femorotibial and tibiocalcaneal angles in a group of knees with a Larsen grade of ≥ 4 (r = 0.544, p = 0.0239). This correlation was stronger in a group with less damaged subtalar joints with a Larsen grade of ≤ 3 (r = 0.705, p = 0.0049). These findings emphasized the importance of examining foot and ankles in patients with RA who undergo total knee arthroplasty.

  18. Use of the ROC anchor in foot and ankle surgery. A retrospective study.

    Science.gov (United States)

    Kuwada, G T

    1999-05-01

    A retrospective study was conducted on the use of the ROC (Radial Osteo Compression) soft-tissue anchor in foot and ankle surgery. This article describes how the anchor is deployed, problematic aspects of using the anchor, and complications and success rates associated with the anchor in ankle stabilizations, posterior tibial tendon reconstruction, peroneus brevis tendon reconstruction after fracture of the base of the fifth metatarsal, and detachment and reattachment of the Achilles tendon. The ROC anchor consists of the anchor with nonabsorbable suture attached to the shaft, the deployment handle, and drill bits. The anchor and shaft are snapped into the deployment handle and inserted into the drill hole. Compression of the trigger deploys the anchor into the hole. The ROC anchor was found to be reliable, useful, and relatively easy to deploy, with outcomes similar to those of other soft-tissue anchors.

  19. Electrochemical corrosion of carbon-fiber-reinforced plastic-metal electrode couples in corrosion media

    International Nuclear Information System (INIS)

    Chukalovskaya, T.V.; Shcherbakov, A.I.; Chigirinskaya, L.A.; Bandurkin, V.V.; Medova, I.L.; Chukalovskij, P.A.

    1995-01-01

    Polarization diagrams, obtained for carbon-fiber-reinforced plastic(cathode)-metallic material(anode) contact couples are analyzed to predict the corrosion behaviour of some technical metals and alloys (carbon steel, stainless steels, brass, aluminium, titanium) in contact with carbon-fiber-reinforced plastic in differen agressive media (H 2 SO 4 , HCl, H 3 PO 4 , NaOH solutions in wide temperature and concentration range, synthetic seawater at 30 and 50 deg C). The predicted behaviour was supported by direct investigation into carbon-fiber-reinforced plastic-titanium and carbon-fiber-reinforced plastic-aluminium contact couples at different square ratios. 6 refs.; 4 figs

  20. Management of diabetic neuropathic foot and ankle malunions and nonunions

    Directory of Open Access Journals (Sweden)

    John J. Stapleton

    2011-05-01

    Full Text Available The management of diabetic neuropathic foot and ankle malunions and/or nonunions is often complicated by the presence of broken or loosened hardware, Charcot joints, infection, osteomyelitis, avascular bone necrosis, unstable deformities, bone loss, disuse and pathologic osteopenia, and ulcerations. The author discusses a rational approach to functional limb salvage with various surgical techniques that are aimed at achieving anatomic alignment, long-term osseous stability, and adequate soft tissue coverage. Emphasis is placed on techniques to overcome the inherent challenges that are encountered when surgically managing a diabetic nonunion and/or malunion. Particular attention is directed to the management of deep infection and Charcot neuroarthropathy in the majority of the cases presented.

  1. Is There Any Association Between Foot Posture and Lower Limb-Related Injuries in Professional Male Basketball Players? A Cross-Sectional Study.

    Science.gov (United States)

    Lopezosa-Reca, Eva; Gijon-Nogueron, Gabriel; Morales-Asencio, Jose Miguel; Cervera-Marin, Jose Antonio; Luque-Suarez, Alejandro

    2017-12-19

    Several studies have shown that foot posture is related to the incidence of ankle sprains in athletes and in nonathletic populations, but this association has not previously been considered in basketball players. This study investigates the relationship between foot posture and lower limb injuries in elite basketball players. Two hundred twenty participants were recruited as a convenience sample. The players had a mean age of 22.51 ± 3.88 years and a body mass index of 23.98 ± 1.80. The players' medical records were accessed from the preceding 10 years, and injuries were recorded according to their location (knee, foot, and/or ankle). In addition, the Foot Posture Index (FPI) was scored for each player, and their playing positions were noted. An average FPI score of 2.66 was obtained across all players, with guards presenting a significantly lower average FPI of -0.48 (P patellar tendinopathy (n = 126). Patellar tendinopathy was more common in supinated feet (30.08%) compared with 20.7% and 19.8% in pronated and neutral feet, respectively. The most common lower limb injuries observed in basketball players were lateral ankle sprain and patellar tendinopathy. Patellar tendinopathy was more commonly associated with the supinated feet. Guard players tended to have a more supinated foot, whereas centers presented a more pronated foot.

  2. Predictive Behavior of a Computational Foot/Ankle Model through Artificial Neural Networks.

    Science.gov (United States)

    Chande, Ruchi D; Hargraves, Rosalyn Hobson; Ortiz-Robinson, Norma; Wayne, Jennifer S

    2017-01-01

    Computational models are useful tools to study the biomechanics of human joints. Their predictive performance is heavily dependent on bony anatomy and soft tissue properties. Imaging data provides anatomical requirements while approximate tissue properties are implemented from literature data, when available. We sought to improve the predictive capability of a computational foot/ankle model by optimizing its ligament stiffness inputs using feedforward and radial basis function neural networks. While the former demonstrated better performance than the latter per mean square error, both networks provided reasonable stiffness predictions for implementation into the computational model.

  3. Knock knee and the gait of six-year-old children.

    Science.gov (United States)

    Pretkiewicz-Abacjew, E

    2003-06-01

    Knock knee (genu valgum) interferes with the locomotive and supporting function of the lower limb. In static conditions the load-bearing axis of the valgus limb is displaced laterally in relation to the middle of the joint, causing the knee joint, the ankle joint, and the foot as a whole to be weighted in the wrong way. The purpose of this work is to examine the influence of knock knee on gait kinematics. The gait of twenty-two 6-year-old children of both sexes in whom knock knee had been medically diagnosed was compared with the gait of 33 children of the same age whose knee joints conformed to the norm in formation and position. Gait was recorded separately for the sagittal and the frontal planes, using a video-computer system. The results of the examination indicated statistically significant differences in the gait of the two groups of children. These differences related mainly to the time features of gait and to data on the angles in the knee and ankle joints. Although the results obtained for other features of gait did not reveal statistical differences, these did indicate that the children with knock knee walked more slowly and with a lower cadence. The results indicate that knock knee in 6-year-old children has an adverse impact on the mechanics of the lower limb joints in gait and causes a deterioration in gait quality. Thus knock knee in children should not be treated merely as a superficial defect but should be subject to therapy and, more importantly, taken into account when introducing children to early sports training.

  4. An experiment on the use of disposable plastics as a reinforcement in concrete beams

    Science.gov (United States)

    Chowdhury, Mostafiz R.

    1992-01-01

    Illustrated here is the concept of reinforced concrete structures by the use of computer simulation and an inexpensive hands-on design experiment. The students in our construction management program use disposable plastic as a reinforcement to demonstrate their understanding of reinforced concrete and prestressed concrete beams. The plastics used for such an experiment vary from plastic bottles to steel reinforced auto tires. This experiment will show the extent to which plastic reinforcement increases the strength of a concrete beam. The procedure of using such throw-away plastics in an experiment to explain the interaction between the reinforcement material and concrete, and a comparison of the test results for using different types of waste plastics are discussed. A computer analysis to simulate the structural response is used to compare the test results and to understand the analytical background of reinforced concrete design. This interaction of using computers to analyze structures and to relate the output results with real experimentation is found to be a very useful method for teaching a math-based analytical subject to our non-engineering students.

  5. The efficacy of the Ankle Mimicking Prosthetic Foot prototype 4.0 during walking: Physiological determinants.

    Science.gov (United States)

    De Pauw, Kevin; Cherelle, Pierre; Roelands, Bart; Lefeber, Dirk; Meeusen, Romain

    2018-04-01

    Evaluating the effectiveness of a novel prosthetic device during walking is an important step in product development. To investigate the efficacy of a novel quasi-passive ankle prosthetic device, Ankle Mimicking Prosthetic Foot 4.0, during walking at different speeds, using physiological determinants in transtibial and transfemoral amputees. Nonrandomized crossover design for amputees. Six able-bodied subjects, six unilateral transtibial amputees, and six unilateral transfemoral amputees underwent a 6-min walk test at normal speed, followed by series of 2-min walking at slow, normal, and fast speeds. The intensity of effort and subjective measures were determined. Amputees performed all walking tests on a treadmill with current and novel prostheses. Shapiro-Wilk normality tests and parametric and nonparametric tests were conducted (p 4.0 is a novel quasi-passive ankle prosthesis with state-of-the-art technological parts. Subjective measures show the importance of this technology, but the intensity of effort during walking still remains higher compared to current passive prostheses, especially in transfemoral amputees.

  6. Publications Rates for Podium and Poster Presentations from the American Orthopaedic Foot & Ankle Society.

    Science.gov (United States)

    Williams, Benjamin R; Kunas, Grace C; Deland, Jonathan T; Ellis, Scott J

    2017-01-01

    National orthopaedic meetings are used to disseminate current research through podium and poster abstract presentations. Not all of these abstracts go on to full-text journal publication. The purpose of this study was to determine the publication rates of podium and poster presentations from the American Orthopaedic Foot & Ankle Society (AOFAS) annual meetings between 2008 and 2012. All accepted podium and poster abstracts from the 2008-2012 AOFAS annual meetings were compiled from the AOFAS office, Physician Resource Center website, and hardcopy meeting programs. PubMed and Google Scholar searches were performed for journal publications using key words in the presentation abstracts and authors' names. Full-text journal publication rates for the presentations were calculated per year, as were the most common journals of publication. Overall full-text publication rate was 73.7% for podium presentations and 55.8% for posters. Podium presentations were published in a journal significantly more often than posters ( P poster presentations, respectively ( P = .124). The most common journal for podium and poster publications was Foot & Ankle International. Podium abstracts were significantly more likely to be published compared to posters. The AOFAS overall full-text journal publication rate was one of the higher reported rates compared with other national orthopedic society meetings, which have ranged from 34% to 73%.

  7. Modulation of recurrent inhibition from knee extensors to ankle motoneurones during human walking

    DEFF Research Database (Denmark)

    Lamy, Jean-Charles; Iglesias, Caroline; Lackmy, Alexandra

    2008-01-01

    The neural control for muscle coordination during human locomotion involves spinal and supraspinal networks, but little is known about the exact mechanisms implicated. The present study focused on modulation of heteronymous recurrent inhibition from knee extensors to ankle motoneurones at different...... times in the gait cycle, when quadriceps (Quad) muscle activity overlaps that in tibialis anterior (TA) and soleus (Sol). The effects of femoral nerve stimulation on ankle motoneurones were investigated during treadmill walking and during tonic co-contraction of Quad and TA/Sol while standing. Recurrent...... inhibition of TA motoneurones depended on the level of background EMG, and was similar during walking and standing for matched background EMG levels. On the other hand, recurrent inhibition in Sol was reduced in early stance, with respect to standing, and enhanced in late stance. Reduced inhibition in Sol...

  8. The effect of deep excavation-induced lateral soil movements on the behavior of strip footing supported on reinforced sand

    Directory of Open Access Journals (Sweden)

    Mostafa El Sawwaf

    2012-10-01

    Full Text Available This paper presents the results of laboratory model tests on the influence of deep excavation-induced lateral soil movements on the behavior of a model strip footing adjacent to the excavation and supported on reinforced granular soil. Initially, the response of the strip footings supported on un-reinforced sand and subjected to vertical loads (which were constant during the test due to adjacent deep excavation-induced lateral soil movement were obtained. Then, the effects of the inclusion of geosynthetic reinforcement in supporting soil on the model footing behavior under the same conditions were investigated. The studied factors include the value of the sustained footing loads, the location of footing relative to the excavation, the affected depth of soil due to deep excavation, and the relative density of sand. Test results indicate that the inclusion of soil reinforcement in the supporting sand significantly decreases both vertical settlements and the tilts of the footings due to the nearby excavation. However, the improvements in the footing behavior were found to be very dependent on the location of the footing relative to excavation. Based on the test results, the variation of the footing measured vertical settlements with different parameters are presented and discussed.

  9. Examination of a muscular activity estimation model using a Bayesian network for the influence of an ankle foot orthosis.

    Science.gov (United States)

    Inoue, Jun; Kawamura, Kazuya; Fujie, Masakatsu G

    2012-01-01

    In the present paper, we examine the appropriateness of a new model to examine the activity of the foot in gait. We developed an estimation model for foot-ankle muscular activity in the design of an ankle-foot orthosis by means of a statistical method. We chose three muscles for measuring muscular activity and built a Bayesian network model to confirm the appropriateness of the estimation model. We experimentally examined the normal gait of a non-disabled subject. We measured the muscular activity of the lower foot muscles using electromyography, the joint angles, and the pressure on each part of the sole. From these data, we obtained the causal relationship at every 10% level for these factors and built models for the stance phase, control term, and propulsive term. Our model has three advantages. First, it can express the influences that change during gait because we use 10% level nodes for each factor. Second, it can express the influences of factors that differ for low and high muscular-activity levels. Third, we created divided models that are able to reflect the actual features of gait. In evaluating the new model, we confirmed it is able to estimate all muscular activity level with an accuracy of over 90%.

  10. Development of a method for fabricating polypropylene non-articulated dorsiflexion assist ankle foot orthoses with predetermined stiffness.

    Science.gov (United States)

    Ramsey, Jason Allan

    2011-03-01

    A non-articulated plantarflexion resist ankle foot orthosis (AFO), commonly known as a posterior leaf spring AFO, is indicated for patients with motor impairment to the dorsiflexors. The AFO is often custom molded to a patient's lower limb anatomy and fabricated from polypropylene. There are no established guidelines for fabricating this type of AFO with predetermined stiffness of the ankle region for normal walking speeds. Therefore an AFO may not meet the biomechanical needs of the patient. Quantify the biomechanical ankle stiffness requirement for an individual with complete dorsiflexor impairment and develop a method for fabricating an AFO with ankle stiffness to meet that requirement. Experimental, bench research. The literature on sagittal biomechanics of non-pathological adults was reviewed to derive the stiffness of the ankle during loading response. Computer models of 144 AFOs were created with geometric variations to account for differences in human anthropometrics. Computer-based finite element analysis was employed to determine the stiffness and safety factor of the models. Stiffness of the AFOs ranged from 0.04 to 1.8 Nm/deg. This ample range is expected to account for the stiffness required for most adults with complete dorsiflexor impairment. At 5° deflection the factor of safety (ratio of strength to stress) ranged from 2.8 to 9.1. A computer program was generated that computes AFO stiffness from user-input variables of AFO geometry. The stiffness is compared to a theoretically appropriate stiffness based on the patient mass. The geometric variables can be modified until there is a close match, resulting in AFO design specification that is appropriate for the patient. Through validation on human subjects, this method may benefit patient outcomes in clinical practice by avoiding the current uncertainty surrounding AFO performance and reducing the labor and time involved in rectifying a custom AFO post-fabrication. This method provides an avenue for

  11. Ultrasound-guided therapeutic injections for neural pathology about the foot and ankle: a 4 year retrospective review.

    Science.gov (United States)

    Walter, William R; Burke, Christopher J; Adler, Ronald S

    2017-06-01

    To describe a 4-year clinical experience with ultrasound-guided therapeutic perineural injections of peripheral nerves about the foot and ankle. Retrospective analysis of foot and ankle perineural injections performed between January 2012 and August 2016. Demographics, clinical indications, presence of structural pathology, immediate and interval pain relief, as well as complications were recorded. Fifty-nine therapeutic injections were performed among 46 patients, accounting for multiple injections in a single visit or multiple visits [mean age = 43 years (range 18-75), 31 female (67%) and 15 male (33%)]. Most commonly, perineural injections involved the hallux branch of the medial plantar nerve (n = 17, 22%). Least commonly, perineural injections involved the saphenous nerve (n = 3, 4%). Other injections in our series include sural (10), superficial (11) and deep (7) peroneal, medial (5) and lateral (3) plantar nerves, and the posterior tibial nerve (3). Ultrasound evaluation revealed structural abnormality associated with the nerve in 30 cases (51%)-most commonly thickening with perineural scarring (n = 14). Of 45 injections with complete documentation, immediate relief of symptoms was reported in 43 (96%) cases. Interval symptom relief was achieved in 23 injections [short term (n = 12), intermediate (n = 6), and long term (n = 5)] out of 38 for which follow-up was available (61%). Complications are rare, occurring in only one case. Ultrasound-guided perineural injections about the foot and ankle are safe and provide lasting symptomatic relief for many indications. Concomitant sonographic evaluation identifies structural abnormalities that may contribute to neuropathic symptoms, allowing targeting of injection or clinical therapy.

  12. Feedback and feedforward locomotor adaptations to ankle-foot load in people with incomplete spinal cord injury.

    Science.gov (United States)

    Gordon, Keith E; Wu, Ming; Kahn, Jennifer H; Schmit, Brian D

    2010-09-01

    Humans with spinal cord injury (SCI) modulate locomotor output in response to limb load. Understanding the neural control mechanisms responsible for locomotor adaptation could provide a framework for selecting effective interventions. We quantified feedback and feedforward locomotor adaptations to limb load modulations in people with incomplete SCI. While subjects airstepped (stepping performed with kinematic assistance and 100% bodyweight support), a powered-orthosis created a dorisflexor torque during the "stance phase" of select steps producing highly controlled ankle-load perturbations. When given repetitive, stance phase ankle-load, the increase in hip extension work, 0.27 J/kg above baseline (no ankle-load airstepping), was greater than the response to ankle-load applied during a single step, 0.14 J/kg (P = 0.029). This finding suggests that, at the hip, subjects produced both feedforward and feedback locomotor modulations. We estimate that, at the hip, the locomotor response to repetitive ankle-load was modulated almost equally by ongoing feedback and feedforward adaptations. The majority of subjects also showed after-effects in hip kinetic patterns that lasted 3 min in response to repetitive loading, providing additional evidence of feedforward locomotor adaptations. The magnitude of the after-effect was proportional to the response to repetitive ankle-foot load (R(2) = 0.92). In contrast, increases in soleus EMG amplitude were not different during repetitive and single-step ankle-load exposure, suggesting that ankle locomotor modulations were predominately feedback-based. Although subjects made both feedback and feedforward locomotor adaptations to changes in ankle-load, between-subject variations suggest that walking function may be related to the ability to make feedforward adaptations.

  13. Functional electrical stimulation and ankle foot orthoses provide equivalent therapeutic effects on foot drop: A meta-analysis providing direction for future research

    Directory of Open Access Journals (Sweden)

    Sarah Prenton

    2017-10-01

    Full Text Available Objective: To compare the randomized controlled trial evidence for therapeutic effects on walking of functional electrical stimulation and ankle foot orthoses for foot drop caused by central nervous system conditions. Data sources: MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials, REHABDATA, PEDro, NIHR Centre for Reviews and Dissemination, Scopus and clinicaltrials.gov. Study selection: One reviewer screened titles/abstracts. Two independent reviewers then screened the full articles. Data extraction: One reviewer extracted data, another screened for accuracy. Risk of bias was assessed by 2 independent reviewers using the Cochrane Risk of Bias Tool. Data synthesis: Eight papers were eligible; 7 involving participants with stroke and 1 involving participants with cerebral palsy. Two papes reporting different measures from the same trial were grouped, resulting in 7 synthesized randomized controlled trials (n= 464. Meta-analysis of walking speed at final assessment (p = 0.46, for stroke participants (p = 0.54 and after 4–6 weeks’ use (p = 0.49 showed equal improvement for both devices. Conclusion: Functional electrical stimulation and ankle foot orthoses have an equally positive therapeutic effect on walking speed in non-progressive central nervous system diagnoses. The current randomized controlled trial evidence base does not show whether this improvement translates into the user’s own environment or reveal the mechanisms that achieve that change. Future studies should focus on measuring activity, muscle activity and gait kinematics. They should also report specific device details, capture sustained therapeutic effects and involve a variety of central nervous system diagnoses.

  14. Modeling and simulating the neuromuscular mechanisms regulating ankle and knee joint stiffness during human locomotion.

    Science.gov (United States)

    Sartori, Massimo; Maculan, Marco; Pizzolato, Claudio; Reggiani, Monica; Farina, Dario

    2015-10-01

    This work presents an electrophysiologically and dynamically consistent musculoskeletal model to predict stiffness in the human ankle and knee joints as derived from the joints constituent biological tissues (i.e., the spanning musculotendon units). The modeling method we propose uses electromyography (EMG) recordings from 13 muscle groups to drive forward dynamic simulations of the human leg in five healthy subjects during overground walking and running. The EMG-driven musculoskeletal model estimates musculotendon and resulting joint stiffness that is consistent with experimental EMG data as well as with the experimental joint moments. This provides a framework that allows for the first time observing 1) the elastic interplay between the knee and ankle joints, 2) the individual muscle contribution to joint stiffness, and 3) the underlying co-contraction strategies. It provides a theoretical description of how stiffness modulates as a function of muscle activation, fiber contraction, and interacting tendon dynamics. Furthermore, it describes how this differs from currently available stiffness definitions, including quasi-stiffness and short-range stiffness. This work offers a theoretical and computational basis for describing and investigating the neuromuscular mechanisms underlying human locomotion. Copyright © 2015 the American Physiological Society.

  15. The Effect of Passive Movement for Paretic Ankle-Foot and Brain Activity in Post-Stroke Patients.

    Science.gov (United States)

    Vér, Csilla; Emri, Miklós; Spisák, Tamás; Berényi, Ervin; Kovács, Kázmér; Katona, Péter; Balkay, László; Menyhárt, László; Kardos, László; Csiba, László

    2016-01-01

    This study aims at investigating the short-term efficacy of the continuous passive motion (CPM) device developed for the therapy of ankle-foot paresis and to investigate by fMRI the blood oxygen level-dependent responses (BOLD) during ankle passive movement (PM). Sixty-four stroke patients were investigated. Patients were assigned into 2 groups: 49 patients received both 15 min manual and 30 min device therapy (M + D), while the other group (n = 15) received only 15 min manual therapy (M). A third group of stroke patients (n = 12) was investigated by fMRI before and immediately after 30 min CPM device therapy. There was no direct relation between the fMRI group and the other 2 groups. All subjects were assessed using the Modified Ashworth Scale (MAS) and a goniometer. Mean MAS decreased, the ankle's mean plantar flexion and dorsiflexion passive range of motion (PROM) increased and the equinovalgus improved significantly in the M + D group. In the fMRI group, the PM of the paretic ankle increased BOLD responses; this was observed in the contralateral pre- and postcentral gyrus, superior temporal gyrus, central opercular cortex, and in the ipsilateral postcentral gyrus, frontal operculum cortex and cerebellum. Manual therapy with CPM device therapy improved the ankle PROM, equinovalgus and severity of spasticity. The ankle PM increased ipsi- and contralateral cortical activation. © 2016 S. Karger AG, Basel.

  16. Short-term changes in running mechanics and foot strike pattern after introduction to minimalistic footwear.

    Science.gov (United States)

    Willson, John D; Bjorhus, Jordan S; Williams, D S Blaise; Butler, Robert J; Porcari, John P; Kernozek, Thomas W

    2014-01-01

    Minimalistic footwear has garnered widespread interest in the running community, based largely on the premise that the footwear may reduce certain running-related injury risk factors through adaptations in running mechanics and foot strike pattern. To examine short-term adaptations in running mechanics among runners who typically run in conventional cushioned heel running shoes as they transition to minimalistic footwear. A 2-week, prospective, observational study. A movement science laboratory. Nineteen female runners with a rear foot strike (RFS) pattern who usually train in conventional running shoes. The participants trained for 20 minutes, 3 times per week for 2 weeks by using minimalistic footwear. Three-dimensional lower extremity running mechanics were analyzed before and after this 2-week period. Hip, knee, and ankle joint kinematics at initial contact; step length; stance time; peak ankle joint moment and joint work; impact peak; vertical ground reaction force loading rate; and foot strike pattern preference were evaluated before and after the intervention. The knee flexion angle at initial contact increased 3.8° (P < .01), but the ankle and hip flexion angles at initial contact did not change after training. No changes in ankle joint kinetics or running temporospatial parameters were observed. The majority of participants (71%), before the intervention, demonstrated an RFS pattern while running in minimalistic footwear. The proportion of runners with an RFS pattern did not decrease after 2 weeks (P = .25). Those runners who chose an RFS pattern in minimalistic shoes experienced a vertical loading rate that was 3 times greater than those who chose to run with a non-RFS pattern. Few systematic changes in running mechanics were observed among participants after 2 weeks of training in minimalistic footwear. The majority of the participants continued to use an RFS pattern after training in minimalistic footwear, and these participants experienced higher

  17. Durability Characteristics Analysis of Plastic Worm Wheel with Glass Fiber Reinforced Polyamide.

    Science.gov (United States)

    Kim, Gun-Hee; Lee, Jeong-Won; Seo, Tae-Il

    2013-05-10

    Plastic worm wheel is widely used in the vehicle manufacturing field because it is favorable for weight lightening, vibration and noise reduction, as well as corrosion resistance. However, it is very difficult for general plastics to secure the mechanical properties that are required for vehicle gears. If the plastic resin is reinforced by glass fiber in the fabrication process of plastic worm wheel, it is possible to achieve the mechanical properties of metallic material levels. In this study, the mechanical characteristic analysis of the glass-reinforced plastic worm wheel, according to the contents of glass fiber, is performed by analytic and experimental methods. In the case of the glass fiber-reinforced resin, the orientation and contents of glass fibers can influence the mechanical properties. For the characteristic prediction of plastic worm wheel, computer-aided engineering (CAE) analysis processes such as structural and injection molding analysis were executed with the polyamide resin reinforcement glass fiber (25 wt %, 50 wt %). The injection mold for fabricating the prototype plastic worm wheel was designed and made to reflect the CAE analysis results. Finally, the durability of prototype plastic worm wheel fabricated by the injection molding process was evaluated by the experimental method and the characteristics according to the glass fiber contents.

  18. Dr. Peter Cavanaugh Explains the Need and Operation of the FOOT Experiment

    Science.gov (United States)

    2003-01-01

    This video clip is an interview with Dr. Peter Cavanaugh, principal investigator for the FOOT experiment. He explains the reasoning behind the experiment and shows some video clips of the FOOT experiment being calibrated and conducted in orbit. The heart of the FOOT experiment is an instrumented suit called the Lower Extremity Monitoring Suit (LEMS). This customized garment is a pair of Lycra cycling tights incorporating 20 carefully placed sensors and the associated wiring control units, and amplifiers. LEMS enables the electrical activity of the muscles, the angular motions of the hip, knee, and ankle joints, and the force under both feet to be measured continuously. Measurements are also made on the arm muscles. Information from the sensors can be recorded up to 14 hours on a small, wearable computer.

  19. Post-Traumatic Osteoarthritis of the Ankle: A Distinct Clinical Entity Requiring New Research Approaches

    Science.gov (United States)

    Delco, Michelle L.; Kennedy, John G.; Bonassar, Lawrence J.; Fortier, Lisa A.

    2017-01-01

    The diagnosis of ankle osteoarthritis (OA) is increasing as a result of advancements in non-invasive imaging modalities such as magnetic resonance imaging, improved arthroscopic surgical technology and heightened awareness among clinicians. Unlike OA of the knee, primary or age-related ankle OA is rare, with the majority of ankle OA classified as post-traumatic (PTOA). Ankle trauma, more specifically ankle sprain, is the single most common athletic injury, and no effective therapies are available to prevent or slow progression of PTOA. Despite the high incidence of ankle trauma and OA, ankle-related OA research is sparse, with the majority of clinical and basic studies pertaining to the knee joint. Fundamental differences exist between joints including their structure and molecular composition, response to trauma, susceptibility to OA, clinical manifestations of disease, and response to treatment. Considerable evidence suggests that research findings from knee should not be extrapolated to the ankle, however few ankle-specific preclinical models of PTOA are currently available. The objective of this article is to review the current state of ankle OA investigation, highlighting important differences between the ankle and knee that may limit the extent to which research findings from knee models are applicable to the ankle joint. Considerations for the development of new ankle-specific, clinically relevant animal models are discussed. PMID:27764893

  20. Effect of foot orthoses on magnitude and timing of rearfoot and tibial motions, ground reaction force and knee moment during running.

    Science.gov (United States)

    Eslami, Mansour; Begon, Mickaël; Hinse, Sébastien; Sadeghi, Heydar; Popov, Peter; Allard, Paul

    2009-11-01

    Changes in magnitude and timing of rearfoot eversion and tibial internal rotation by foot orthoses and their contributions to vertical ground reaction force and knee joint moments are not well understood. The objectives of this study were to test if orthoses modify the magnitude and time to peak rearfoot eversion, tibial internal rotation, active ground reaction force and knee adduction moment and determine if rearfoot eversion, tibial internal rotation magnitudes are correlated to peak active ground reaction force and knee adduction moment during the first 60% stance phase of running. Eleven healthy men ran at 170 steps per minute in shod and with foot orthoses conditions. Video and force-plate data were collected simultaneously to calculate foot joint angular displacement, ground reaction forces and knee adduction moments. Results showed that wearing semi-rigid foot orthoses significantly reduced rearfoot eversion 40% (4.1 degrees ; p=0.001) and peak active ground reaction force 6% (0.96N/kg; p=0.008). No significant time differences occurred among the peak rearfoot eversion, tibial internal rotation and peak active ground reaction force in both conditions. A positive and significant correlation was observed between peak knee adduction moment and the magnitude of rearfoot eversion during shod (r=0.59; p=0.04) and shod/orthoses running (r=0.65; p=0.02). In conclusion, foot orthoses could reduce rearfoot eversion so that this can be associated with a reduction of knee adduction moment during the first 60% stance phase of running. Finding implies that modifying rearfoot and tibial motions during running could not be related to a reduction of the ground reaction force.

  1. Studies examining the efficacy of ankle foot orthoses should report activity level and mechanical evidence.

    Science.gov (United States)

    Harlaar, Jaap; Brehm, Merel; Becher, Jules G; Bregman, Daan J J; Buurke, Jaap; Holtkamp, Fred; De Groot, Vincent; Nollet, Frans

    2010-09-01

    Ankle Foot Orthoses (AFOs) to promote walking ability are a common treatment in patients with neurological or muscular diseases. However, guidelines on the prescription of AFOs are currently based on a low level of evidence regarding their efficacy. Recent studies aiming to demonstrate the efficacy of wearing an AFO in respect to walking ability are not always conclusive. In this paper it is argued to recognize two levels of evidence related to the ICF levels. Activity level evidence expresses the gain in walking ability for the patient, while mechanical evidence expresses the correct functioning of the AFO. Used in combination for the purpose of evaluating the efficacy of orthotic treatment, a conjunct improvement at both levels reinforces the treatment algorithm that is used. Conversely, conflicting outcomes will challenge current treatment algorithms and the supposed working mechanism of the AFO. A treatment algorithm must use relevant information as an input, derived from measurements with a high precision. Its result will be a specific AFO that matches the patient's needs, specified by the mechanical characterization of the AFO footwear combination. It is concluded that research on the efficacy of AFOs should use parameters from two levels of evidence, to prove the efficacy of a treatment algorithm, i.e., how to prescribe a well-matched AFO.

  2. Orthotic management of instability of the knee related to neuromuscular and central nervous system disorders: systematic review, qualitative study, survey and costing analysis.

    OpenAIRE

    O'Connor, Joanne; McCaughan, Dorothy; McDaid, Catriona; Booth, Alison; Fayter, Debra; Rodriguez-Lopez, Roccio; Bowers, Roy; Dyson, Lisa; Iglesias, Cynthia P; Lalor, Simon; O'Connor, Rory J; Phillips, Margaret; Ramdharry, Gita

    2016-01-01

    BACKGROUND: \\ud \\ud Patients who have knee instability that is associated with neuromuscular disease (NMD) and central nervous system (CNS) conditions can be treated using orthoses, such as knee-ankle-foot orthoses (KAFOs).\\ud \\ud OBJECTIVES: \\ud \\ud To assess existing evidence on the effectiveness of orthoses; patient perspectives; types of orthotic devices prescribed in the UK NHS; and associated costs.\\ud \\ud METHODS: \\ud \\ud Qualitative study of views of orthoses users - a qualitative in-...

  3. Validation of Foot Placement Locations from Ankle Data of a Kinect v2 Sensor.

    Science.gov (United States)

    Geerse, Daphne; Coolen, Bert; Kolijn, Detmar; Roerdink, Melvyn

    2017-10-10

    The Kinect v2 sensor may be a cheap and easy to use sensor to quantify gait in clinical settings, especially when applied in set-ups integrating multiple Kinect sensors to increase the measurement volume. Reliable estimates of foot placement locations are required to quantify spatial gait parameters. This study aimed to systematically evaluate the effects of distance from the sensor, side and step length on estimates of foot placement locations based on Kinect's ankle body points. Subjects (n = 12) performed stepping trials at imposed foot placement locations distanced 2 m or 3 m from the Kinect sensor (distance), for left and right foot placement locations (side), and for five imposed step lengths. Body points' time series of the lower extremities were recorded with a Kinect v2 sensor, placed frontoparallelly on the left side, and a gold-standard motion-registration system. Foot placement locations, step lengths, and stepping accuracies were compared between systems using repeated-measures ANOVAs, agreement statistics and two one-sided t -tests to test equivalence. For the right side at the 2 m distance from the sensor we found significant between-systems differences in foot placement locations and step lengths, and evidence for nonequivalence. This distance by side effect was likely caused by differences in body orientation relative to the Kinect sensor. It can be reduced by using Kinect's higher-dimensional depth data to estimate foot placement locations directly from the foot's point cloud and/or by using smaller inter-sensor distances in the case of a multi-Kinect v2 set-up to estimate foot placement locations at greater distances from the sensor.

  4. Predictive Behavior of a Computational Foot/Ankle Model through Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Ruchi D. Chande

    2017-01-01

    Full Text Available Computational models are useful tools to study the biomechanics of human joints. Their predictive performance is heavily dependent on bony anatomy and soft tissue properties. Imaging data provides anatomical requirements while approximate tissue properties are implemented from literature data, when available. We sought to improve the predictive capability of a computational foot/ankle model by optimizing its ligament stiffness inputs using feedforward and radial basis function neural networks. While the former demonstrated better performance than the latter per mean square error, both networks provided reasonable stiffness predictions for implementation into the computational model.

  5. Use of glass-reinforced plastic vessels in petrochemical production plants

    International Nuclear Information System (INIS)

    Makarov, V.G.; Baikin, V.G.; Perlin, S.M.

    1984-01-01

    At present, petrochemical plant production equipment is made of scarce high-alloy steels and alloys or carbon steel with subsequent chemical protection. Traditional methods of protection frequently do not provide reliable and safe service of equipment for the length of the normal operating life. One of the effective methods of combatting corrosion is the use of glass-reinforced plastic equipment. Glass-reinforced equipment is not subject to electrochemical corrosion and has a high chemical resistance. Weight is approximately a third of similar vessels. The paper provides recommendations and precautions for the production, installation, use and maintenance of glass-reinforced plastic vessels

  6. Plastic ingestion by Flesh-footed Shearwaters (Puffinus carneipes): Implications for fledgling body condition and the accumulation of plastic-derived chemicals.

    Science.gov (United States)

    Lavers, Jennifer L; Bond, Alexander L; Hutton, Ian

    2014-04-01

    To provide much needed quantitative data on the lethal and sublethal effects of plastic pollution on marine wildlife, we sampled breast feathers and stomach contents from Flesh-footed Shearwater (Puffinus carneipes) fledglings in eastern Australia. Birds with high levels of ingested plastic exhibited reduced body condition and increased contaminant load (p plastic ingestion by seabirds, with 16% of fledglings failing these targets after a single feeding (range: 0.13-3.21 g of plastic/feeding). As top predators, seabirds are considered sentinels of the marine environment. The amount of plastic ingested and corresponding damage to Flesh-footed Shearwater fledglings is the highest reported for any marine vertebrate, suggesting the condition of the Australian marine environment is poor. These findings help explain the ongoing decline of this species and are worrying in light of increasing levels of plastic pollution in our oceans. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Assessment of female ballet dancers' ankles in the en pointe position using high field strength magnetic resonance imaging.

    Science.gov (United States)

    Russell, Jeffrey A; Yoshioka, Hiroshi

    2016-08-01

    The en pointe position of the ankle in ballet is extreme. Previously, magnetic resonance imaging (MRI) of ballet dancers' ankles en pointe was confined to a low field, open MR device. To develop a reproducible ankle MRI protocol for ballet dancers en pointe and to assess the positions of the key structures in the dancers ankles. Six female ballet dancers participated; each was randomly assigned to stand en pointe while one of her feet and ankles was splinted with wooden rods affixed with straps or to begin with the ankle in neutral position. She lay in an MR scanner with the ankle inside a knee coil for en pointe imaging and inside an ankle/foot coil for neutral position imaging. Proton density weighted images with and without fat suppression and 3D water excitation gradient recalled echo images were obtained en pointe and in neutral position in sagittal, axial, and coronal planes. We compared the bones, cartilage, and soft tissues within and between positions. No difficulties using the protocol were encountered. En pointe the posterior articular surface of the tibial plafond was incongruent with the talar dome and rested on the posterior talus. The posterior edge of the plafond impinged Kager's fat pad. All participants exhibited one or more small ganglion cysts about the ankle and proximal foot, as well as fluid accumulation in the flexor and fibularis tendon sheaths. Our MRI protocol allows assessment of female ballet dancers' ankles in the extreme plantar flexion position in which the dancers perform. We consistently noted incongruence of the talocrural joint and convergence of the tibia, talus, and calcaneus posteriorly. This protocol may be useful for clinicians who evaluate dancers. © The Foundation Acta Radiologica 2015.

  8. The Effect of Rocker Bar Ankle Foot Orthosis on Functional Mobility in Post-Stroke Hemiplegic Patients

    Directory of Open Access Journals (Sweden)

    Farzad Farmani

    2015-09-01

    Full Text Available Objectives: Ankle Foot Orthoses (AFOs are widely utilized to improve walking ability in hemiplegic patients. The present study aimed to evaluate the effect of Rocker bar Ankle Foot Orthosis (RAFO on functional mobility in post-stroke hemiplegic patients. Methods: Fifteen hemiplegic patients (men and women who were at least 6-months post-stroke and able to walk without assistive device for at least 10 meters voluntarily participated in this study. The patients were examined with and without RAFO. Their functional mobility was evaluated through 10-meter walk test and Timed Up and Go (TUG test. Also, paired t-test was used to analyze obtained data. Results: When patients used RAFO, their gait speed significantly increased (P<0.05. Also, the time of performing TUG test experienced a significant decrease using RAFO compared with utilizing shoe only (P<0.05. Discussion: RAFO led to a significant improvement in functional mobility in hemiplegic patient’s secondary to stroke. It seems that, it has been due to the positive effect of rocker modification on improving push off and transferring weight during stance phase of gait.

  9. Reliability and validity analysis of the open-source Chinese Foot and Ankle Outcome Score (FAOS).

    Science.gov (United States)

    Ling, Samuel K K; Chan, Vincent; Ho, Karen; Ling, Fona; Lui, T H

    2017-12-21

    Develop the first reliable and validated open-source outcome scoring system in the Chinese language for foot and ankle problems. Translation of the English FAOS into Chinese following regular protocols. First, two forward-translations were created separately, these were then combined into a preliminary version by an expert committee, and was subsequently back-translated into English. The process was repeated until the original and back translations were congruent. This version was then field tested on actual patients who provided feedback for modification. The final Chinese FAOS version was then tested for reliability and validity. Reliability analysis was performed on 20 subjects while validity analysis was performed on 50 subjects. Tools used to validate the Chinese FAOS were the SF36 and Pain Numeric Rating Scale (NRS). Internal consistency between the FAOS subgroups was measured using Cronbach's alpha. Spearman's correlation was calculated between each subgroup in the FAOS, SF36 and NRS. The Chinese FAOS passed both reliability and validity testing; meaning it is reliable, internally consistent and correlates positively with the SF36 and the NRS. The Chinese FAOS is a free, open-source scoring system that can be used to provide a relatively standardised outcome measure for foot and ankle studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Detection of Gait Modes Using an Artificial Neural Network during Walking with a Powered Ankle-Foot Orthosis

    Science.gov (United States)

    2016-01-01

    This paper presents an algorithm, for use with a Portable Powered Ankle-Foot Orthosis (i.e., PPAFO) that can automatically detect changes in gait modes (level ground, ascent and descent of stairs or ramps), thus allowing for appropriate ankle actuation control during swing phase. An artificial neural network (ANN) algorithm used input signals from an inertial measurement unit and foot switches, that is, vertical velocity and segment angle of the foot. Output from the ANN was filtered and adjusted to generate a final data set used to classify different gait modes. Five healthy male subjects walked with the PPAFO on the right leg for two test scenarios (walking over level ground and up and down stairs or a ramp; three trials per scenario). Success rate was quantified by the number of correctly classified steps with respect to the total number of steps. The results indicated that the proposed algorithm's success rate was high (99.3%, 100%, and 98.3% for level, ascent, and descent modes in the stairs scenario, respectively; 98.9%, 97.8%, and 100% in the ramp scenario). The proposed algorithm continuously detected each step's gait mode with faster timing and higher accuracy compared to a previous algorithm that used a decision tree based on maximizing the reliability of the mode recognition. PMID:28070188

  11. The Relationship of Static Anthropometric Measurements to Lower Leg, Ankle, and Foot Injuries in Air Force Academy Cadets: A Prospective Longitudinal Study

    National Research Council Canada - National Science Library

    McMahon, Thomas

    2001-01-01

    The purpose of this prospective cohort study was to investigate the relationship between static anthropometric measures or demographical information and overuse injuries in the lower leg, ankle and foot...

  12. Ankle Fractures Often Not Diagnosed

    Science.gov (United States)

    ... top of the talus is dome-shaped and... Softball Injuries to the Foot and Ankle Your feet ... ankles take a beating when you are playing softball. Softball players should be aware of the following ...

  13. Restoration of ankle movements with the ActiGait implantable drop foot stimulator: a safe and reliable treatment option for permanent central leg palsy.

    Science.gov (United States)

    Martin, Klaus Daniel; Polanski, Witold Henryk; Schulz, Anne-Kathrin; Jöbges, Michael; Hoff, Hansjoerg; Schackert, Gabriele; Pinzer, Thomas; Sobottka, Stephan B

    2016-01-01

    OBJECT The ActiGait drop foot stimulator is a promising technique for restoration of lost ankle function by an implantable hybrid stimulation system. It allows ankle dorsiflexion by active peroneal nerve stimulation during the swing phase of gait. In this paper the authors report the outcome of the first prospective study on a large number of patients with stroke-related drop foot. METHODS Twenty-seven patients who experienced a stroke and with persisting spastic leg paresis received an implantable ActiGait drop foot stimulator for restoration of ankle movement after successful surface test stimulation. After 3 to 5 weeks, the stimulator was activated, and gait speed, gait endurance, and activation time of the system were evaluated and compared with preoperative gait tests. In addition, patient satisfaction was assessed using a questionnaire. RESULTS Postoperative gait speed significantly improved from 33.9 seconds per 20 meters to 17.9 seconds per 20 meters (p < 0.0001), gait endurance from 196 meters in 6 minutes to 401 meters in 6 minutes (p < 0.0001), and activation time from 20.5 seconds to 10.6 seconds on average (p < 0.0001). In 2 patients with nerve injury, surgical repositioning of the electrode cuff became necessary. One patient showed a delayed wound healing, and in another patient the system had to be removed because of a wound infection. Marked improvement in mobility, social participation, and quality of life was confirmed by 89% to 96% of patients. CONCLUSIONS The ActiGait implantable drop foot stimulator improves gait speed, endurance, and quality of life in patients with stroke-related drop foot. Regarding gait speed, the ActiGait system appears to be advantageous compared with foot orthosis or surface stimulation devices. Randomized trials with more patients and longer observation periods are needed to prove the long-term benefit of this device.

  14. Development of Ankle Foot Orthosis (AFO Using Pneumatic Artificial Muscle for Disabled Children

    Directory of Open Access Journals (Sweden)

    Ishak N.Z.

    2017-01-01

    Full Text Available Ankle foot orthosis (AFO are commonly used to correct the instabilities and joint weakness of lower limb. In this research, AFO was developed by using pneumatic artificial muscle (PAM to prevent plantarflexion to occur and also to correct the foot from the inversion syndrome. The research started with designing the AFO by using SolidWorks software based on anthropometry measurement data (n=5, age=12 years old. The mechanical simulation was conducted by using Autodesk Inventor software to obtain a safety factor before the fabrication process was conducted. The AFO was fabricated using 3D printer and the thermoplastic elastomer (TPE rubber was selected as the material. PAM was tested by using test bed machine to generate the force and contraction by muscle. The result shows that the PAM was suitable for low speed as the displacement was greater. The AFO could be valuable for the gait rehabilitation.

  15. Is ankle contracture after stroke due to abnormal intermuscular force transmission?

    Science.gov (United States)

    Diong, Joanna; Herbert, Robert D

    2015-02-01

    Contracture after stroke could be due to abnormal mechanical interactions between muscles. This study examined if ankle plantarflexor muscle contracture after stroke is due to abnormal force transmission between the gastrocnemius and soleus muscles. Muscle fascicle lengths were measured from ultrasound images of soleus muscles in five subjects with stroke and ankle contracture and six able-bodied subjects. Changes in soleus fascicle length or pennation during passive knee extension at fixed ankle angle were assumed to indicate intermuscular force transmission. Changes in soleus fascicle length or pennation were adjusted for changes in ankle motion. Subjects with stroke had significant ankle contracture. After adjustment for ankle motion, 9 of 11 subjects demonstrated small changes in soleus fascicle length with knee extension, suggestive of intermuscular force transmission. However, the small changes in fascicle length may have been artifacts caused by movement of the ultrasound transducers. There were no systematic differences in change in fascicle length (median between-group difference adjusting for ankle motion = -0.01, 95% CI -0.26-0.08 mm/degree of knee extension) or pennation (-0.05, 95% CI -0.15-0.07 degree/ degree of knee extension). This suggests ankle contractures after stroke were not due to abnormal (systematically increased or decreased) intermuscular force transmission between the gastrocnemius and soleus.

  16. Telemark skiing injuries: an 11-year study.

    Science.gov (United States)

    Made, C; Borg, H; Thelander, D; Elmqvist, L G

    2001-11-01

    This study evaluated telemark injuries in a Swedish ski area in terms of injury ratio, location, and causes over time. During the seasons of 1989-2000 all injured telemark skiers ( n=94) who attended the medical center in Tärnaby, Sweden, within 48 h after the accident were registered and asked to fill in an injury form. A control group of noninjured telemark skiers were interviewed in the season of 1999-2000. The most common cause of injury was fall (70%) and the injury ratio was 1.2. There was a higher proportion of beginners in the injured population, and they had a fall/run ratio of 0.7, compared with 0.3 for average and advanced skiers. Ankle/foot injuries were most common (28% of injuries) followed by knee (20%) and head/neck (17%). The ankle/foot injuries decreased from 35% to 22% in the seasons 1989-1995 to 1995-2000. Beginners had more ankle/foot injuries than skilled participants. The severity of ankle/foot injuries classified as the Abbreviated Injury Scale group 2 or higher decreased from 33% to 21% during the study period. Twenty-seven percent used plastic and 73% leather boots. We found no association between boot material and ankle/foot injuries. The proportion of high boots with two or more buckles was 51%. High boots appeared to be protective against ankle/foot injuries. The proportion of high boots increased from 24% to 67% during the study period. Thus ankle/foot injuries were the most common injury location, but have decreased over time. The severity of these injuries has also decreased. A possible explanation could be the increased use of high boots.

  17. Rendezvous technique for recanalization of long-segmental chronic total occlusion above the knee following unsuccessful standard angioplasty.

    Science.gov (United States)

    Cao, Jun; Lu, Hai-Tao; Wei, Li-Ming; Zhao, Jun-Gong; Zhu, Yue-Qi

    2016-04-01

    To assess the technical feasibility and efficacy of the rendezvous technique, a type of subintimal retrograde wiring, for the treatment of long-segmental chronic total occlusions above the knee following unsuccessful standard angioplasty. The rendezvous technique was attempted in eight limbs of eight patients with chronic total occlusions above the knee after standard angioplasty failed. The clinical symptoms and ankle-brachial index were compared before and after the procedure. At follow-up, pain relief, wound healing, limb salvage, and the presence of restenosis of the target vessels were evaluated. The rendezvous technique was performed successfully in seven patients (87.5%) and failed in one patient (12.5%). Foot pain improved in all seven patients who underwent successful treatment, with ankle-brachial indexes improving from 0.23 ± 0.13 before to 0.71 ± 0.09 after the procedure (P rendezvous technique is a feasible and effective treatment for chronic total occlusions above the knee when standard angioplasty fails. © The Author(s) 2015.

  18. The deformity correction and fixator-assisted treatment using Ilizarov versus Taylor spatial frame in the foot and ankle

    Directory of Open Access Journals (Sweden)

    Yudha Manggala

    2018-02-01

    Full Text Available This study was to report the comparison of outcomes between Ilizarov ring fixator (IRF and Taylor Spatial Frame® (Smith & Nephew, Memphis, Tenn.; TSF in terms of the effectiveness of ankle-foot deformities correction, follow-up results, and complications. Fourteen patients with ankle-foot deformities were corrected using circular external fixation (IRF group = 7 patients; TSF group = 7 patients and related procedures. Baseline data and treatment variables were recorded. The patients’ mean age was 42.9 years. Mean follow-up time was 6.5 months. Most common cause of deformity/traumatic condition was posttraumatic equinus. There were successful results in 8 patients (57.1%, partial successful results in 5 patients (35.7%, and revision-needed in 1 patient (7.1%. TSF group demonstrated significantly higher rate of successful results than IRF group (P=0.033. A trend of lower complication rate was found in TSF group (P=0.286. Deformity corrections using TSF provided significantly better clinical scores and higher rate of successful outcome than conventional IRF.

  19. Coralline hydroxyapatite: a bone graft alternative in foot and ankle surgery.

    Science.gov (United States)

    Rahimi, F; Maurer, B T; Enzweiler, M G

    1997-01-01

    The use of coralline hydroxyapatite has become a viable bone grafting alternative. Its efficacy has been well established through multiple human and animal studies. Coralline hydroxyapatite enhances osteogenesis by providing a biocompatible lattice for the passage and assembly of vascular, fibroblastic, and osteoblastic tissues. It also provides support for surrounding osseous structures. The uses of this material are expanding into the realm of foot and ankle surgery. Its consideration as an appropriate bone graft substitute as well as multiple case studies demonstrating its surgical applicability are discussed. The implants utilized at Thorek Hospital and Medical Center over the past eight years, with an average follow-up of three and one-half years, have proven to be a valuable resource for augmentation where an osseous defect has occurred.

  20. Ankle foot orthoses for people with Charcot Marie Tooth disease--views of users and orthotists on important aspects of use.

    Science.gov (United States)

    Phillips, Margaret; Radford, Kathryn; Wills, Adrian

    2011-01-01

    To explore important aspects of the benefits, important characteristics, barriers to use and disadvantages of using ankle foot orthoses (AFOs) as seen by people with Charcot Marie Tooth disease (CMT) and the orthotists who will fit and supply them. This qualitative study used the nominal group technique and individual semi-structured interviews, according to participant preference and ability to travel. Propositions were put to 15 participants (eight females) with CMT regarding benefits, disadvantages, barriers to use and important characteristics of ankle foot orthoses AFOs and regarding benefits and disadvantages to seven orthotists. Priorities in these areas were ranked and a thematic analysis of the free text was made separately by two observers and a joint decision made of final themes. Fifteen people (eight females) with CMT and seven orthotists participated. Users' themes concerned functional mobility walking, pain/discomfort, choice of AFOs and associated footwear, custom made design, use in practical situations and support for foot and ankle. They noted that AFOs improved walking, but practical aspects of use and provision, as well as consideration of cosmetic aspects, were frequently problematic. Orthotists had similar themes, but with a difference in emphasis, that included prevention of future complications, education regarding device limitations and craftsmanship as a further theme. Users understood the potential benefits of AFOs and could identify disadvantages which might be remedied, but were frustrated by the difficulties in translating this into practice. Further refinement of current orthoses and delivery of orthotic services may assist in addressing these issues. © 2011 Informa UK, Ltd.

  1. Primary ankle arthrodesis for neglected open Weber B ankle fracture dislocation.

    Science.gov (United States)

    Thomason, Katherine; Ramesh, Ashwanth; McGoldrick, Niall; Cove, Richard; Walsh, James C; Stephens, Michael M

    2014-01-01

    Primary ankle arthrodesis used to treat a neglected open ankle fracture dislocation is a unique decision. A 63-year-old man presented to the emergency department with a 5-day-old open fracture dislocation of his right ankle. After thorough soft tissue debridement, primary arthrodesis of the tibiotalar joint was performed using initial Kirschner wire fixation and an external fixator. Definitive soft tissue coverage was later achieved using a latissimus dorsi free flap. The fusion was consolidated to salvage the limb from amputation. The use of primary arthrodesis to treat a compound ankle fracture dislocation has not been previously described. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Joint angles of the ankle, knee, and hip and loading conditions during split squats.

    Science.gov (United States)

    Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio

    2014-06-01

    The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.

  3. Fixation Strength of Polyetheretherketone Sheath-and-Bullet Device for Soft Tissue Repair in the Foot and Ankle.

    Science.gov (United States)

    Christensen, Jay; Fischer, Brian; Nute, Michael; Rizza, Robert

    Tendon transfers are often performed in the foot and ankle. Recently, interference screws have been a popular choice owing to their ease of use and fixation strength. Considering the benefits, one disadvantage of such devices is laceration of the soft tissues by the implant threads during placement that potentially weaken the structural integrity of the grafts. A shape memory polyetheretherketone bullet-in-sheath tenodesis device uses circumferential compression, eliminating potential damage from thread rotation and maintaining the soft tissue orientation of the graft. The aim of this study was to determine the pullout strength and failure mode for this device in both a synthetic bone analogue and porcine bone models. Thirteen mature bovine extensor tendons were secured into ten 4.0 × 4.0 × 4.0-cm cubes of 15-pound per cubic foot solid rigid polyurethane foam bone analogue models or 3 porcine femoral condyles using the 5 × 20-mm polyetheretherketone soft tissue anchor. The bullet-in-sheath device demonstrated a mean pullout of 280.84 N in the bone analog models and 419.47 N in the porcine bone models. (p = .001). The bullet-in-sheath design preserved the integrity of the tendon graft, and none of the implants dislodged from their original position. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Simulated impacts of ankle foot orthoses on muscle demand and recruitment in typically-developing children and children with cerebral palsy and crouch gait.

    Directory of Open Access Journals (Sweden)

    Michael Rosenberg

    Full Text Available Passive ankle foot orthoses (AFOs are often prescribed for children with cerebral palsy (CP to assist locomotion, but predicting how specific device designs will impact energetic demand during gait remains challenging. Powered AFOs have been shown to reduce energy costs of walking in unimpaired adults more than passive AFOs, but have not been tested in children with CP. The goal of this study was to investigate the potential impact of powered and passive AFOs on muscle demand and recruitment in children with CP and crouch gait. We simulated gait for nine children with crouch gait and three typically-developing children with powered and passive AFOs. For each AFO design, we computed reductions in muscle demand compared to unassisted gait. Powered AFOs reduced muscle demand 15-44% compared to unassisted walking, 1-14% more than passive AFOs. A slower walking speed was associated with smaller reductions in absolute muscle demand for all AFOs (r2 = 0.60-0.70. However, reductions in muscle demand were only moderately correlated with crouch severity (r2 = 0.40-0.43. The ankle plantarflexor muscles were most heavily impacted by the AFOs, with gastrocnemius recruitment decreasing 13-73% and correlating with increasing knee flexor moments (r2 = 0.29-0.91. These findings support the potential use of powered AFOs for children with crouch gait, and highlight how subject-specific kinematics and kinetics may influence muscle demand and recruitment to inform AFO design.

  5. The influence of knee alignment on lower extremity kinetics during squats.

    Science.gov (United States)

    Slater, Lindsay V; Hart, Joseph M

    2016-12-01

    The squat is an assessment of lower extremity alignment during movement, however there is little information regarding altered joint kinetics during poorly performed squats. The purpose of this study was to examine changes in joint kinetics and power from altered knee alignment during a squat. Thirty participants completed squats while displacing the knee medially, anteriorly, and with neutral alignment (control). Sagittal and frontal plane torques at the ankle, knee, and hip were altered in the descending and ascending phase of the squat in both the medial and anterior malaligned squat compared to the control squat. Ankle and trunk power increased and hip power decreased in the medial malaligned squat compared to the control squat. Ankle, knee, and trunk power increased and hip power decreased in the anterior malaligned squat compared to the control squat. Changes in joint torques and power during malaligned squats suggest that altered knee alignment increases ankle and trunk involvement to execute the movement. Increased anterior knee excursion during squatting may also lead to persistent altered loading of the ankle and knee. Sports medicine professionals using the squat for quadriceps strengthening must consider knee alignment to reduce ankle and trunk involvement during the movement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults.

    Science.gov (United States)

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (pisometric strength provided reliable test-retest measures in healthy older adults. Ib.

  7. Fracture detection in concrete by glass fiber cloth reinforced plastics

    Science.gov (United States)

    Shin, Soon-Gi; Lee, Sung-Riong

    2006-04-01

    Two types of carbon (carbon fiber and carbon powder) and a glass cloth were used as conductive phases and a reinforcing fiber, respectively, in polymer rods. The carbon powder was used for fabricating electrically conductive carbon powder-glass fiber reinforced plastic (CP-GFRP) rods. The carbon fiber tows and the CP-GFRP rods were adhered to mortar specimens using epoxy resin and glass fiber cloth. On bending, the electrical resistance of the carbon fiber tow attached to the mortar specimen increased greatly after crack generation, and that of the CP-GFRP rod increased after the early stages of deflection in the mortar. Therefore, the CP-GFRP rod is superior to the carbon fiber tow in detecting fractures. Also, by reinforcing with a glass fiber cloth reinforced plastic, the strength of the mortar specimens became more than twice as strong as that of the unreinforced mortar.

  8. Dynamic balance deficits in individuals with chronic ankle instability compared to ankle sprain copers 1 year after a first-time lateral ankle sprain injury.

    Science.gov (United States)

    Doherty, Cailbhe; Bleakley, Chris; Hertel, Jay; Caulfield, Brian; Ryan, John; Delahunt, Eamonn

    2016-04-01

    To quantify the dynamic balance deficits that characterise a group with chronic ankle instability compared to lateral ankle sprain copers and non-injured controls using kinematic and kinetic outcomes. Forty-two participants with chronic ankle instability and twenty-eight lateral ankle sprain copers were initially recruited within 2 weeks of sustaining a first-time, acute lateral ankle sprain and required to attend our laboratory 1 year later to complete the current study protocol. An additional group of non-injured individuals were also recruited to act as a control group. All participants completed the anterior, posterior-lateral and posterior-medial reach directions of the star excursion balance test. Sagittal plane kinematics of the lower extremity and associated fractal dimension of the centre of pressure path were also acquired. Participants with chronic ankle instability displayed poorer performance in the anterior, posterior-medial and posterior-lateral reach directions compared with controls bilaterally, and in the posterior-lateral direction compared with lateral ankle sprain copers on their 'involved' limb only. These performance deficits in the posterior-lateral and posterior-medial directions were associated with reduced flexion and dorsiflexion displacements at the hip, knee and ankle at the point of maximum reach, and coincided with reduced complexity of the centre of pressure path. In comparison with lateral ankle sprain copers and controls, participants with chronic ankle instability were characterised by dynamic balance deficits as measured using the SEBT. This was attested to reduced sagittal plane motions at the hip, knee and ankle joints, and reduced capacity of the stance limb to avail of its supporting base. III.

  9. Lower extremity joint coupling variability during gait in young adults with and without chronic ankle instability.

    Science.gov (United States)

    Lilley, Thomas; Herb, Christopher C; Hart, Joseph; Hertel, Jay

    2018-06-01

    Chronic ankle instability (CAI) is a condition resulting from a lateral ankle sprain. Shank-rearfoot joint-coupling variability differences have been found in CAI patients; however, joint-coupling variability (VCV) of the ankle and proximal joints has not been explored. Our purpose was to analyse VCV in adults with and without CAI during gait. Four joint-coupling pairs were analysed: knee sagittal-ankle sagittal, knee sagittal-ankle frontal, hip frontal-ankle sagittal and hip frontal-ankle frontal. Twenty-seven adults participated (CAI:n = 13, Control:n = 14). Lower extremity kinematics were collected during walking (4.83 km/h) and jogging (9.66 km/h). Vector-coding was used to assess the stride-to-stride variability of four coupling pairs. During walking, CAI patients exhibited higher VCV than healthy controls for knee sagittal-ankle frontal in latter parts of stance thru mid-swing. When jogging, CAI patients demonstrated lower VCV with specific differences occurring across various intervals of gait. The increased knee sagittal-ankle frontal VCV in CAI patients during walking may indicate an adaptation to deal with the previously identified decrease in variability in transverse plane shank and frontal plane rearfoot coupling during walking; while the decreased ankle-knee and ankle-hip VCV identified in CAI patients during jogging may represent a more rigid, less adaptable sensorimotor system ambulating at a faster speed.

  10. Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat

    Directory of Open Access Journals (Sweden)

    Simic Milena

    2010-11-01

    Full Text Available Abstract Background Muscle function may influence the risk of knee injury and outcomes following injury. Clinical tests, such as a single-limb mini squat, resemble conditions of daily life and are easy to administer. Fewer squats per 30 seconds indicate poorer function. However, the quality of movement, such as the medio-lateral knee motion may also be important. The aim was to validate an observational clinical test of assessing the medio-lateral knee motion, using a three-dimensional (3-D motion analysis system. In addition, the inter-rater reliability was evaluated. Methods Twenty-five (17 women non-injured participants (mean age 25.6 years, range 18-37 were included. Visual analysis of the medio-lateral knee motion, scored as knee-over-foot or knee-medial-to-foot by two raters, and 3-D kinematic data were collected simultaneously during a single-limb mini squat. Frontal plane 2-D peak tibial, thigh, and knee varus-valgus angles, and 3-D peak hip internal-external rotation, and knee varus-valgus angles were calculated. Results Ten subjects were scored as having a knee-medial-to-foot position and 15 subjects a knee-over-foot position assessed by visual inspection. In 2-D, the peak tibial angle (mean 89.0 (SE 0.7 vs mean 86.3 (SE 0.4 degrees, p = 0.001 and peak thigh angle (mean 77.4 (SE 1.0 vs mean 81.2 (SE 0.5 degrees, p = 0.001 with respect to the horizontal, indicated that the knee was more medially placed than the ankle and thigh, respectively. Thus, the knee was in more valgus (mean 11.6 (SE 1.5 vs 5.0 (SE 0.8 degrees, p 0.90 and 96 between raters. Conclusions Medio-lateral motion of the knee can reliably be assessed during a single-leg mini-squat. The test is valid in 2-D, while the actual movement, in 3-D, is mainly exhibited as increased internal hip rotation. The single-limb mini squat is feasible and easy to administer in the clinical setting and in research to address lower extremity movement quality.

  11. Structural Analysis of Basalt Fiber Reinforced Plastic Wind Turbine Blade

    Directory of Open Access Journals (Sweden)

    Mengal Ali Nawaz

    2014-07-01

    Full Text Available In this study, Basalt fiber reinforced plastic (BFRP wind turbine blade was analyzed and compared with Glass fiber reinforced plastic blade (GFRP. Finite element analysis (FEA of blade was carried out using ANSYS. Data for FEA was obtained by using rule of mixture. The shell element in ANSYS was used to simulate the wind turbine blade and to conduct its strength analysis. The structural analysis and comparison of blade deformations proved that BFRP wind turbine blade has better strength compared to GFRP wind turbine blade.

  12. Cross-cultural adaptation and validation of Spanish version of The Foot and Ankle Ability Measures (FAAM-Sp).

    Science.gov (United States)

    Cervera-Garvi, Pablo; Ortega-Avila, Ana Belen; Morales-Asencio, Jose Miguel; Cervera-Marin, Jose Antonio; Martin, Rob Roy; Gijon-Nogueron, Gabriel

    2017-01-01

    The Foot and Ankle Ability Measure (FAAM) is a Patient Reported Outcome (PRO) commonly used to determine the effectiveness of therapeutic interventions for patients with foot and ankle pathologies and associated impairments of body function and structure, activity limitations, and participation restrictions. The aim of this study was to cross-culturally adapt the FAAM into Spanish. Cross-cultural adaptation was performed according to the international guidelines of the International Society for Pharmacoeconomics and Outcomes Research. Cronbach's alpha, test re-test reliability, and item-total and inter-item correlations were analyzed. Confirmatory factor analysis (CFA) was carried out to test construct validity. Pearson correlations were calculated to assess the convergent validity between FAAM and EuroQol-5. Spanish data set comprised 194 patients, with a mean age of 38.45 (16.04) and 130 (67.1%) were female, seeing a podiatrist with a wide variety of foot and ankle related disorders. CFA was carried out to test structure matrix (which has three factors). The test-retest reliability was high with global ICC of 0.95 (95% CI: 0.93 to 0.98). A 15 items version of the FAAM-Sp Activities of Daily Living (ADL) obtained the best fit: relative chi-square ( x 2 /df) of 2.46, GFI 0.90 CFI 0.95, NFI 0.93, and RMSEA 0.08 (90% CI 0.04 to 0.09). For exploratory factor analysis for the FAAM-Sp Sport, a one factor solution was obtained, which explained 76.70% of total variance. CFA corroborated this model with an excellent goodness of fit:: relative chi-square ( x 2 /df) of 0.80, GFI 0.99 CFI 1.00, NFI 0.99, and RMSEA 0.00 (90% CI 0.00 to 0.75). This study validated a new 15-item FAAM-Sp ADL and FAAM-Sp Sport subscales, which can be used as a self-reported outcome measure in clinical practice and research for patients resident in Spain whose main language is Spanish.

  13. Measurement properties of the most commonly used Foot- and Ankle-Specific Questionnaires: the FFI, FAOS and FAAM. A systematic review

    NARCIS (Netherlands)

    Sierevelt, I. N.; Zwiers, R.; Schats, W.; Haverkamp, D.; Terwee, C. B.; Nolte, P. A.; Kerkhoffs, G. M. M. J.

    2017-01-01

    In the foot and ankle literature, a wide range of patient-reported outcome measures (PROMs) is used, however, consensus as to which PROMs are preferred is lacking. Selection of a PROM is among other reasons, often based on measurement properties without considering the methodological quality of the

  14. Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking

    Science.gov (United States)

    Caputo, Joshua M.; Collins, Steven H.

    2014-12-01

    Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementally varied in isolation from one-half to two-times normal levels while subjects with simulated amputation walked on a treadmill at 1.25 m.s-1. Increased prosthesis push-off significantly reduced metabolic energy expenditure, with a 14% reduction at maximum prosthesis work. In contrast to model predictions, however, collision losses were unchanged, while hip work during swing initiation was decreased. This suggests that powered ankle push-off reduces walking effort primarily through other mechanisms, such as assisting leg swing, which would be better understood using more complete neuromuscular models.

  15. Reconstruction of bilateral tibial aplasia and split hand-foot syndrome in a father and daughter.

    Science.gov (United States)

    Al Kaissi, Ali; Ganger, Rudolf; Klaushofer, Klaus; Grill, Franz

    2014-01-01

    Tibial aplasia is of heterogeneous aetiology, the majority of reports are sporadic. We describe the reconstruction procedures in two subjects - a daughter and father manifested autosomal dominant (AD) inheritance of the bilateral tibial aplasia and split hand-foot syndrome. Reconstruction of these patients required multiple surgical procedures and orthoprosthesis was mandatory. The main goal of treatment was to achieve walking. Stabilization of the ankle joint by fibular-talar-chondrodesis on both sides, followed by bilateral Brown-procedure at the knee joint level has been applied accordingly. The outcome was with improved function of the deformed limbs and walking was achieved with simultaneous designation of orthotic fitting. This is the first study encompassing the diagnosis and management of a father and daughter with bilateral tibial aplasia associated with variable split hand/foot deformity without foot ablation. Our patients showed the typical AD pattern of inheritance of split-hand/foot and tibial aplasia.

  16. Locomotor adaptation to a powered ankle-foot orthosis depends on control method

    Directory of Open Access Journals (Sweden)

    Gordon Keith E

    2007-12-01

    Full Text Available Abstract Background We studied human locomotor adaptation to powered ankle-foot orthoses with the intent of identifying differences between two different orthosis control methods. The first orthosis control method used a footswitch to provide bang-bang control (a kinematic control and the second orthosis control method used a proportional myoelectric signal from the soleus (a physiological control. Both controllers activated an artificial pneumatic muscle providing plantar flexion torque. Methods Subjects walked on a treadmill for two thirty-minute sessions spaced three days apart under either footswitch control (n = 6 or myoelectric control (n = 6. We recorded lower limb electromyography (EMG, joint kinematics, and orthosis kinetics. We compared stance phase EMG amplitudes, correlation of joint angle patterns, and mechanical work performed by the powered orthosis between the two controllers over time. Results During steady state at the end of the second session, subjects using proportional myoelectric control had much lower soleus and gastrocnemius activation than the subjects using footswitch control. The substantial decrease in triceps surae recruitment allowed the proportional myoelectric control subjects to walk with ankle kinematics close to normal and reduce negative work performed by the orthosis. The footswitch control subjects walked with substantially perturbed ankle kinematics and performed more negative work with the orthosis. Conclusion These results provide evidence that the choice of orthosis control method can greatly alter how humans adapt to powered orthosis assistance during walking. Specifically, proportional myoelectric control results in larger reductions in muscle activation and gait kinematics more similar to normal compared to footswitch control.

  17. Aqueous immersion technique for the irradiation with photons Kaposi's sarcoma multiple foot and ankle

    International Nuclear Information System (INIS)

    Velazquez Miranda, S.; Munoz Carmona, D. M.; Ortyiz Seidel, M.; Gomez-Millan Barrachina, J.; Delgado Gil, M. M.; Ortega Rodriguez, M. J.; Dominguez Rodriguez, M.; Marquez Garcia Salazar, M.; Bayo Lozano, E.

    2011-01-01

    Classic Kaposi sarcoma presents as asymptomatic red-violaceus plaques, usually on the legs below the knees, ankles and soles preferentially. When the disease is spread on the skin preferential treatment is radiation therapy at low doses. Homogeneous irradiation of the various lesions could be very complex due to the irregular geometry of the feet, interdigital lesions on different planes. To overcome this problem, and in the case of disseminated disease and low doses, we propose the technique of dipping the tip in Cuba expanded polystyrene filled with saline with a methacrylate plate 2 cm in depth and irradiation with parallel opposed fields.

  18. PROMIS Pain Interference and Physical Function Scores Correlate With the Foot and Ankle Ability Measure (FAAM) in Patients With Hallux Valgus.

    Science.gov (United States)

    Nixon, Devon C; McCormick, Jeremy J; Johnson, Jeffrey E; Klein, Sandra E

    2017-11-01

    Traditional patient-reported outcome instruments like the Foot and Ankle Ability Measure (FAAM) quantify patient disability but often are limited by responder burden and incomplete questionnaires. The Patient-Reported Outcome Measurement Information System (PROMIS) overcomes such obstacles through computer-adaptive technology and can capture outcome data from various domains including physical and psychosocial function. Prior work has compared the FAAM with PROMIS physical function; however, there is little evidence comparing the association between foot and ankle-specific tools like the FAAM with more general outcomes measures of PROMIS pain interference and depression in foot and ankle conditions. (1) We asked whether there was a relationship between FAAM Activities of Daily Living (ADL) scores with PROMIS physical function, pain interference, and depression in patients with hallux valgus. (2) Additionally, we asked if we could identify specific factors that are associated with variance in FAAM and PROMIS physical function scores in patients with hallux valgus. Eighty-five new patients with either a primary or secondary diagnosis of hallux valgus based on clinic billing codes from July 2015 to February 2016 were retrospectively identified. Patients completed FAAM ADL paper-based surveys and electronic PROMIS questionnaires for physical function, pain interference, and depression from new patient visits at a single time. Spearman rho correlations were performed between FAAM ADL and PROMIS scores. Analyses then were used to identify differences in FAAM ADL and PROMIS physical function measures based on demographic variables. Stepwise linear regressions then determined which demographic and/or outcome variable(s) accounted for the variance in FAAM ADL and PROMIS physical function scores. FAAM scores correlated strongly with PROMIS physical function (r = 0.70, p hallux valgus. PROMIS tools allow for more-efficient data collection across multiple domains and, moving

  19. Effects of foot and ankle devices on balance, gait and falls in adults with sensory perception loss: a systematic review.

    Science.gov (United States)

    Paton, Joanne; Hatton, Anna L; Rome, Keith; Kent, Bridie

    2016-12-01

    Foot and ankle devices are being developed as a method of preventing people with sensory perception loss sustaining a fall. Such devices are believed to work by reducing the likelihood of a fall by improving the balance and gait of the user. The objective of the review was to evaluate the effectiveness of foot and ankle devices for the prevention of falls and the improvement of balance and gait in adults with sensory perception loss. Participants were community-dwelling adults with bilateral pathological sensory perception loss. The current review evaluated any foot or ankle device, including but not restricted to, all types of footwear (therapeutic and retail), insoles (customized and prefabricated) and ankle-foot orthoses (AFOs). In the absence of randomized controlled trials (RCT), the review considered experimental and epidemiological study designs, except case series, individual case reports and descriptive cross-sectional studies. The primary outcome was number of falls. Secondary outcome measures were clinical or laboratory measures of balance or gait. A search for published and unpublished literature from inception to March 2015 written in the English language was conducted across a number of major electronic databases. A three-step search strategy was developed using MeSH terminology and keywords to ensure all that relevant materials are captured. Methodological quality of included studies was assessed by two reviewers, who appraised each study independently, using standardized Joanna Briggs Institute (JBI) critical appraisal tools. Quantitative data were extracted from the studies that were identified as meeting the criteria for methodological quality using the standardized JBI data extraction tools. Due to the heterogeneity of populations, interventions and outcome measures, meta-analyses were not possible and results are presented in narrative form. Nine trials (from 10 papers) involving 238 participants, (14 with multiple sclerosis and 16 with

  20. Ottawa ankle rules and subjective surgeon perception to evaluate ...

    African Journals Online (AJOL)

    Background: Foot and ankle injuries are frequent in emergency departments. Although only a few patients with foot and ankle sprain present fractures and the fracture patterns are almost always simple, lack of fracture diagnosis can lead to poor functional outcomes. Aim: The present study aims to evaluate the reliability of ...

  1. Ottawa Ankle Rules and Subjective Surgeon Perception to Evaluate ...

    African Journals Online (AJOL)

    Abstract. Background: Foot and ankle injuries are frequent in emergency departments. Although only a few patients with foot and ankle sprain present fractures and the fracture patterns are almost always simple, lack of fracture diagnosis can lead to poor functional outcomes. Aim: The present study aims to evaluate the ...

  2. The Cumberland Ankle Instability Tool (CAIT) in the Dutch population with and without complaints of ankle instability.

    Science.gov (United States)

    Vuurberg, Gwendolyn; Kluit, Lana; van Dijk, C Niek

    2018-03-01

    To develop a translated Dutch version of the Cumberland Ankle Instability Tool (CAIT) and test its psychometric properties in a Dutch population with foot and ankle complaints. The CAIT was translated into the Dutch language using a forward-backward translation design. Of the 130 subsequent patients visiting the outpatient clinic for foot and ankle complaints who were asked to fill out a questionnaire containing the CAIT, the Foot and Ankle Outcome Score (FAOS), and the numeric rating scale (NRS) pain, 98 completed the questionnaire. After a 1-week period, patients were asked to fill out a second questionnaire online containing the CAIT and NRS pain. This second questionnaire was completed by 70 patients. With these data, the construct validity, test-retest reliability, internal consistency, measurement error, and ceiling and floor effects were assessed. Additionally, a cut-off value to discriminate between stable and unstable ankles, in patients with ankle complaints, was calculated. Construct validity showed moderate correlations between the CAIT and FAOS subscales (Spearman's correlation coefficient (SCC) = 0.36-0.43), and the NRS pain (SCC = -0.55). The cut-off value was found at 11.5 points of the total CAIT score (range 0-30). Test-retest reliability showed to be excellent with an intraclass correlation coefficient of 0.94. Internal consistency was high (Cronbach's α = 0.86). No ceiling or floor effects were detected. Based on the results, the Dutch version of the CAIT is a valid and reliable questionnaire to assess ankle instability in the Dutch population and is able to differentiate between a functionally unstable and stable ankle. The tool is the first suitable tool to objectify the severity of ankle instability specific complaints and assess change in the Dutch population. Level of evidence II.

  3. Effect of Acute Alterations in Foot Strike Patterns during Running on Sagittal Plane Lower Limb Kinematics and Kinetics

    Directory of Open Access Journals (Sweden)

    Kevin A. Valenzuela, Scott K. Lynn, Lisa R. Mikelson, Guillermo J. Noffal, Daniel A. Judelson

    2015-03-01

    Full Text Available subjects were identified through slow motion video playback (n = 21, age = 22.8±2.2 years, mass = 73.1±14.5 kg, height 1.75 ± 0.10 m. On day two, subjects performed five overground run trials in both their natural and unnatural strike patterns while motion and force data were collected. Data were collected over two days so that foot strike videos could be analyzed for group placement purposes. Several 2 (Foot Strike Pattern –forefoot strike [FFS], rearfoot strike [RFS] x 2 (Group – PFFG, PRFG mixed model ANOVAs (p < 0.05 were run on speed, active peak vertical ground reaction force (VGRF, peak early stance and mid stance sagittal ankle moments, sagittal plane hip and knee moments, ankle dorsiflexion ROM, and sagittal plane hip and knee ROM. There were no significant interactions or between group differences for any of the measured variables. Within subject effects demonstrated that the RFS condition had significantly lower (VGRF (RFS = 2.58 ± .21 BW, FFS = 2.71 ± 0.23 BW, dorsiflexion moment (RFS = -2.6 1± 0.61 Nm·kg-1, FFS = -3.09 ± 0.32 Nm·kg-1, and dorsiflexion range of motion (RFS = 17.63 ± 3.76°, FFS = 22.10 ± 5.08°. There was also a significantly higher peak plantarflexion moment (RFS = 0.23 ± 0.11 Nm·kg-1, FFS = 0.01 ± 0.01 Nm·kg-1, peak knee moment (RFS = 2.61 ± 0.54 Nm·kg-1, FFS = 2.39 ± 0.61 Nm·kg-1, knee ROM (RFS = 31.72 ± 2.79°, FFS = 29.58 ± 2.97°, and hip ROM (RFS = 42.72 ± 4.03°, FFS = 41.38 ± 3.32° as compared with the FFS condition. This research suggests that acute changes in foot strike patterns during shod running can create alterations in certain lower limb kinematic and kinetic measures that are not dependent on the preferred foot strike pattern of the individual. This research also challenges the contention that the impact transient spike in the vertical ground reaction force curve is only present during a rear foot strike type of running gait.

  4. Clinical examination results in individuals with functional ankle instability and ankle-sprain copers.

    Science.gov (United States)

    Wright, Cynthia J; Arnold, Brent L; Ross, Scott E; Ketchum, Jessica; Ericksen, Jeffrey; Pidcoe, Peter

    2013-01-01

    Why some individuals with ankle sprains develop functional ankle instability and others do not (ie, copers) is unknown. Current understanding of the clinical profile of copers is limited. To contrast individuals with functional ankle instability (FAI), copers, and uninjured individuals on both self-reported variables and clinical examination findings. Cross-sectional study. Sports medicine research laboratory. Participants consisted of 23 individuals with a history of 1 or more ankle sprains and at least 2 episodes of giving way in the past year (FAI: Cumberland Ankle Instability Tool [CAIT] score = 20.52 ± 2.94, episodes of giving way = 5.8 ± 8.4 per month), 23 individuals with a history of a single ankle sprain and no subsequent episodes of instability (copers: CAIT score = 27.74 ± 1.69), and 23 individuals with no history of ankle sprain and no instability (uninjured: CAIT score = 28.78 ± 1.78). Self-reported disability was recorded using the CAIT and Foot and Ankle Ability Measure for Activities of Daily Living and for Sports. On clinical examination, ligamentous laxity and tenderness, range of motion (ROM), and pain at end ROM were recorded. Questionnaire scores for the CAIT, Foot and Ankle Ability Measure for Activities of Daily Living and for Sports, ankle inversion and anterior drawer laxity scores, pain with palpation of the lateral ligaments, ankle ROM, and pain at end ROM. Individuals with FAI had greater self-reported disability for all measures (P < .05). On clinical examination, individuals with FAI were more likely to have greater talar tilt laxity, pain with inversion, and limited sagittal-plane ROM than copers (P < .05). Differences in both self-reported disability and clinical examination variables distinguished individuals with FAI from copers at least 1 year after injury. Whether the deficits could be detected immediately postinjury to prospectively identify potential copers is unknown.

  5. Association between knee alignment and knee pain in patients surgically treated for medial knee osteoarthritis by high tibial osteotomy. A one year follow-up study

    DEFF Research Database (Denmark)

    W-Dahl, Annette; Toksvig-Larsen, Sören; Roos, Ewa

    2009-01-01

    on for knee OA by high tibial osteotomy. METHODS: 182 patients (68% men) mean age 53 years (34 - 69) with varus alignment having tibial osteotomy by the hemicallotasis technique for medial knee OA were consecutively included. Knee alignment was assessed by the Hip-Knee-Ankle (HKA) angle from radiographs...... including the hip and ankle joints. Knee pain was measured by the subscale pain (0 - 100, worst to best scale) of the Knee injury and Osteoarthritis Outcome Score (KOOS) preoperatively and at one year follow-up. To estimate the association between knee alignment and knee pain multivariate regression...... with every degree of HKA angle, adjusted analysis 0.3 points (95% CI -1.3 - 0.6).The mean postoperative knee alignment was 184 degrees (171 - 185). The mean change in knee alignment was 13 degrees (0 - 30). The mean change in KOOS pain was 32 (-16 - 83). There was neither any association between change...

  6. The origin of the ankle

    International Nuclear Information System (INIS)

    Codino, Antonio; Plouin, Francois

    2007-01-01

    The differential intensity of cosmic radiation shows a sequence of depressions referred to as knees in a large energy band above 10 15 eV. The global depression entailed in the complete spectrum with respect to the extrapolated intensity based on low energy data, amounts to a maximum factor of 8, occurring at 5x10 18 eV, where flux measurements exhibit a relative minimum, referred to as the ankle. It is demonstrated by a full simulation of cosmic ray trajectories in the Galaxy that the intensity minimum around the ankle energy is primarily due to the nuclear interactions of the cosmic ions with the interstellar matter and to the galactic magnetic field. Ankles signal the onset energies of the rectilinear propagation in the Milky Way at Earth, being for example, 4x10 18 eV for helium and 6x10 19 eV for iron. The ankle, in spite of its notable importance at Earth, is a local perturbation of the universal spectrum which, between the knee and the ankle, decreases by a round factor 10 9 regaining its unperturbed status above 10 19 eV

  7. Neural Network Optimization of Ligament Stiffnesses for the Enhanced Predictive Ability of a Patient-Specific, Computational Foot/Ankle Model.

    Science.gov (United States)

    Chande, Ruchi D; Wayne, Jennifer S

    2017-09-01

    Computational models of diarthrodial joints serve to inform the biomechanical function of these structures, and as such, must be supplied appropriate inputs for performance that is representative of actual joint function. Inputs for these models are sourced from both imaging modalities as well as literature. The latter is often the source of mechanical properties for soft tissues, like ligament stiffnesses; however, such data are not always available for all the soft tissues nor is it known for patient-specific work. In the current research, a method to improve the ligament stiffness definition for a computational foot/ankle model was sought with the greater goal of improving the predictive ability of the computational model. Specifically, the stiffness values were optimized using artificial neural networks (ANNs); both feedforward and radial basis function networks (RBFNs) were considered. Optimal networks of each type were determined and subsequently used to predict stiffnesses for the foot/ankle model. Ultimately, the predicted stiffnesses were considered reasonable and resulted in enhanced performance of the computational model, suggesting that artificial neural networks can be used to optimize stiffness inputs.

  8. Effect of Providing Ankle-Foot Orthoses in Patients with Acute and Subacute Stroke: a Randomized Controlled Trial : A randomized controlled trial

    NARCIS (Netherlands)

    Nikamp-Simons, Corien D.M.; Buurke, Jaap H.; Van Der Palen, Job; Hermens, Hermie J.; Rietman, Johan S.; Ibánez, Jaime; Azorín, José María; Akay, Metin; Pons, José Luis

    2017-01-01

    Despite frequent application of ankle-foot orthoses (AFOs), little scientific evidence is available to guide AFO-provision early after stroke. A randomized controlled trial was conducted to study the effects of AFO-provision in (sub-) acute stroke patients. Primary aim: to study effects of the

  9. Displacement of popliteal sciatic nerve catheters after major foot and ankle surgery: a randomized controlled double-blinded magnetic resonance imaging study

    DEFF Research Database (Denmark)

    Hauritz, R W; Pedersen, E M; Linde, F S

    2016-01-01

    Popliteal sciatic nerve catheters (PSNCs) are associated with a high frequency of displacement. We aimed to estimate the frequency of catheter displacement after 48 h with magnetic resonance imaging (MRI) in patients with PSNCs after major foot and ankle surgery randomized to catheter insertion e...

  10. Effect of ski mountaineering track on foot sole loading pattern.

    Science.gov (United States)

    Haselbacher, Matthias; Mader, Katharina; Werner, Maximiliane; Nogler, Michael

    2014-09-01

    Ski mountaineering is becoming a popular sport. The ascending techniques (tracks) can be divided into 3 different groups: flat field, direct ascent, and traversing. This study examines the relationship between different mechanical loads on the foot and the 4 different mountaineering ascending techniques. All subjects used the same pair of ski boots and the same skis while performing the 4 different ascending techniques. An in-shoe dynamic pressure measuring system was used to measure the mechanical load on the foot soles of each ski mountaineer. The foot sole was divided into 6 anatomic sections to measure the different loads in each section. Thirteen men with an average age of 29 years were enrolled in the study. The results showed small, not significant differences in the mechanical foot load in the flat field or in the direct ascent. The average mechanical foot load was highest on the valley side foot while traversing (179 kPa to 117 kPa). The higher load forces were in the medial ball of the foot and the longitudinal aspect of the foot side closer to the hill. The higher impact placed on the valley side foot and the concentration of force placed on the medial ball of the valley side foot suggested the influence of the track on the load pattern of the foot sole. This higher impact may result in upward forces that affect the force distribution in the ankle and knee joints. Copyright © 2014. Published by Elsevier Inc.

  11. Footwear interventions for foot pain, function, impairment and disability for people with foot and ankle arthritis: A literature review.

    Science.gov (United States)

    Frecklington, Mike; Dalbeth, Nicola; McNair, Peter; Gow, Peter; Williams, Anita; Carroll, Matthew; Rome, Keith

    2017-11-03

    To conduct a literature review on the effectiveness of footwear on foot pain, function, impairment and disability for people with foot and ankle arthritis. A search of the electronic databases Scopus, Medline, CINAHL, SportDiscus and the Cochrane Library was undertaken in September 2017. The key inclusion criteria were studies reporting on findings of footwear interventions for people with arthritis with foot pain, function, impairment and/or disability. The Quality Index Tool was used to assess the methodological quality of studies included in the qualitative synthesis. The methodological variation of the included studies was assessed to determine the suitability of meta-analysis and the grading of recommendations, assessment, development and evaluation (GRADE) system. Between and within group effect sizes were calculated using Cohen's d. 1440 studies were identified for screening with 11 studies included in the review. Mean (range) quality scores were 67% (39-96%). The majority of studies investigated rheumatoid arthritis (n = 7), but also included gout (n = 2), and 1st metatarsophalangeal joint osteoarthritis (n = 2). Meta-analysis and GRADE assessment were not deemed appropriated based on methodological variation. Footwear interventions included off-the-shelf footwear, therapeutic footwear and therapeutic footwear with foot orthoses. Key footwear characteristics included cushioning and a wide toe box for rheumatoid arthritis; cushioning, midsole stability and a rocker-sole for gout; and a rocker-sole for 1st metatarsophalangeal joint osteoarthritis. Between group effect sizes for outcomes ranged from 0.01 to 1.26. Footwear interventions were associated with reductions in foot pain, impairment and disability for people with rheumatoid arthritis. Between group differences were more likely to be observed in studies with shorter follow-up periods in people with rheumatoid arthritis (12 weeks). Footwear interventions improved foot pain, function and disability in

  12. A bio-based fibre-reinforced plastic pedestrian bridge for Schiphol

    NARCIS (Netherlands)

    Smits, J.E.P.; Gkaidatzis, R.

    2015-01-01

    The present paper investigates Bio-based fibre-reinforced plastics, used as a load-bearing element of a bridge. We aim to increase the renewable content and decreasing the embodied energy of FRP. To achieve that, the consisting raw materials of these plastics which are based on non-renewable

  13. Obese older adults suffer foot pain and foot-related functional limitation.

    Science.gov (United States)

    Mickle, Karen J; Steele, Julie R

    2015-10-01

    There is evidence to suggest being overweight or obese places adults at greater risk of developing foot complications such as osteoarthritis, tendonitis and plantar fasciitis. However, no research has comprehensively examined the effects of overweight or obesity on the feet of individuals older than 60 years of age. Therefore we investigated whether foot pain, foot structure, and/or foot function is affected by obesity in older adults. Three hundred and twelve Australian men and women, aged over 60 years, completed validated questionnaires to establish the presence of foot pain and health related quality of life. Foot structure (anthropometrics and soft tissue thickness) and foot function (ankle dorsiflexion strength and flexibility, toe flexor strength, plantar pressures and spatiotemporal gait parameters) were also measured. Obese participants (BMI >30) were compared to those who were overweight (BMI=25-30) and not overweight (BMI foot pain and scored significantly lower on the SF-36. Obesity was also associated with foot-related functional limitation whereby ankle dorsiflexion strength, hallux and lesser toe strength, stride/step length and walking speed were significantly reduced in obese participants compared to their leaner counterparts. Therefore, disabling foot pain and altered foot structure and foot function are consequences of obesity for older adults, and impact upon their quality of life. Interventions designed to reduce excess fat mass may relieve loading of the foot structures and, in turn, improve foot pain and quality of life for older obese individuals. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. A Novel Approach For Ankle Foot Orthosis Developed By Three Dimensional Technologies

    Science.gov (United States)

    Belokar, R. M.; Banga, H. K.; Kumar, R.

    2017-12-01

    This study presents a novel approach for testing mechanical properties of medical orthosis developed by three dimensional (3D) technologies. A hand-held type 3D laser scanner is used for generating 3D mesh geometry directly from patient’s limb. Subsequently 3D printable orthotic design is produced from crude input model by means of Computer Aided Design (CAD) software. Fused Deposition Modelling (FDM) method in Additive Manufacturing (AM) technologies is used to fabricate the 3D printable Ankle Foot Orthosis (AFO) prototype in order to test the mechanical properties on printout. According to test results, printed Acrylonitrile Butadiene Styrene (ABS) AFO prototype has sufficient elasticity modulus and durability for patient-specific medical device manufactured by the 3D technologies.

  15. Total ankle joint replacement.

    Science.gov (United States)

    2016-02-01

    Ankle arthritis results in a stiff and painful ankle and can be a major cause of disability. For people with end-stage ankle arthritis, arthrodesis (ankle fusion) is effective at reducing pain in the shorter term, but results in a fixed joint, and over time the loss of mobility places stress on other joints in the foot that may lead to arthritis, pain and dysfunction. Another option is to perform a total ankle joint replacement, with the aim of giving the patient a mobile and pain-free ankle. In this article we review the efficacy of this procedure, including how it compares to ankle arthrodesis, and consider the indications and complications. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Rigid-plastic seismic design of reinforced concrete structures

    DEFF Research Database (Denmark)

    Costa, Joao Domingues; Bento, R.; Levtchitch, V.

    2007-01-01

    structural strength with respect to a pre-defined performance parameter using a rigid-plastic response spectrum, which is characteristic of the ground motion alone. The maximum strength demand at any point is solely dependent on the intensity of the ground motion, which facilitates the task of distributing......In this paper a new seismic design procedure for Reinforced Concrete (R/C) structures is proposed-the Rigid-Plastic Seismic Design (RPSD) method. This is a design procedure based on Non-Linear Time-History Analysis (NLTHA) for systems expected to perform in the non-linear range during a lifetime...... earthquake event. The theoretical background is the Theory of Plasticity (Rigid-Plastic Structures). Firstly, a collapse mechanism is chosen and the corresponding stress field is made safe outside the regions where plastic behaviour takes place. It is shown that this allows the determination of the required...

  17. Assessment of effect of reinforcement on plastic limit load of branch junction

    International Nuclear Information System (INIS)

    Myung, Man Sik; Kim, Yun Jae; Yoon, Ki Bong

    2009-01-01

    The present work provides effects of reinforcement shape and area on plastic limit loads of branch junctions, based on detailed three-dimensional finite element limit analysis and small strain FE limit analyses assuming elastic-perfectly plastic material behavior. Three types of loading are considered; internal pressure, in-plane bending on the branch pipe and in-plane bending on the run pipe. It is found that reinforcement is the most effective in the case when (in-plane/out-of-plane) bending is applied to the branch pipe. When bending is applied to the run pipe, reinforcement is less effective, compared to the case when bending is applied to the branch pipe. The reinforcement effect is the least effective for internal pressure.

  18. Reconstruction of bilateral tibial aplasia and split hand-foot syndrome in a father and daughter

    Directory of Open Access Journals (Sweden)

    Ali Al Kaissi

    2014-01-01

    Full Text Available Background: Tibial aplasia is of heterogeneous aetiology, the majority of reports are sporadic. We describe the reconstruction procedures in two subjects - a daughter and father manifested autosomal dominant (AD inheritance of the bilateral tibial aplasia and split hand-foot syndrome. Materials and Methods: Reconstruction of these patients required multiple surgical procedures and orthoprosthesis was mandatory. The main goal of treatment was to achieve walking. Stabilization of the ankle joint by fibular-talar-chondrodesis on both sides, followed by bilateral Brown-procedure at the knee joint level has been applied accordingly. Results: The outcome was with improved function of the deformed limbs and walking was achieved with simultaneous designation of orthotic fitting. Conclusion: This is the first study encompassing the diagnosis and management of a father and daughter with bilateral tibial aplasia associated with variable split hand/foot deformity without foot ablation. Our patients showed the typical AD pattern of inheritance of split-hand/foot and tibial aplasia.

  19. Mechanical and energetic consequences of reduced ankle plantar-flexion in human walking.

    Science.gov (United States)

    Huang, Tzu-wei P; Shorter, Kenneth A; Adamczyk, Peter G; Kuo, Arthur D

    2015-11-01

    The human ankle produces a large burst of 'push-off' mechanical power late in the stance phase of walking, reduction of which leads to considerably poorer energy economy. It is, however, uncertain whether the energetic penalty results from poorer efficiency when the other leg joints substitute for the ankle's push-off work, or from a higher overall demand for work due to some fundamental feature of push-off. Here, we show that greater metabolic energy expenditure is indeed explained by a greater demand for work. This is predicted by a simple model of walking on pendulum-like legs, because proper push-off reduces collision losses from the leading leg. We tested this by experimentally restricting ankle push-off bilaterally in healthy adults (N=8) walking on a treadmill at 1.4 m s(-1), using ankle-foot orthoses with steel cables limiting motion. These produced up to ∼50% reduction in ankle push-off power and work, resulting in up to ∼50% greater net metabolic power expenditure to walk at the same speed. For each 1 J reduction in ankle work, we observed 0.6 J more dissipative collision work by the other leg, 1.3 J more positive work from the leg joints overall, and 3.94 J more metabolic energy expended. Loss of ankle push-off required more positive work elsewhere to maintain walking speed; this additional work was performed by the knee, apparently at reasonably high efficiency. Ankle push-off may contribute to walking economy by reducing dissipative collision losses and thus overall work demand. © 2015. Published by The Company of Biologists Ltd.

  20. Research on carbon fiber–reinforced plastic bumper beam subjected to low-velocity frontal impact

    Directory of Open Access Journals (Sweden)

    Yefa Hu

    2015-06-01

    Full Text Available Lightweight and safety performance of automobiles are two important factors for automobile designs. In this article, a research on lightweight and crashworthiness of automotive bumper has been conducted. The carbon fiber–reinforced plastic bumper beam is considered to replace the traditional high-strength steel one. The low-velocity impact finite element simulations for the above two bumper beams are performed via LS-DYNA. Furthermore, the energy absorption capabilities and dynamic response characteristics of the carbon fiber–reinforced plastic bumper beam are investigated and compared with the steel one. The results show that the carbon fiber–reinforced plastic bumper beam is of the better energy absorption capabilities and dynamic response characteristics than those of the steel one; the weight has decreased remarkably close to 50%. Meanwhile, the effect of lay-up and wall thickness on the crashworthiness of the carbon fiber–reinforced plastic bumper beam under low-velocity impact is also studied in this article to select appropriate design schemes.

  1. The effectiveness of foot orthotics in improving postural control in individuals with chronic ankle instability: a critically appraised topic.

    Science.gov (United States)

    Gabriner, Michael L; Braun, Brittany A; Houston, Megan N; Hoch, Matthew C

    2015-02-01

    Chronic ankle instability (CAI) is a condition commonly experienced by physically active individuals. It has been suggested that foot orthotics may increase a CAI patient's postural control. For patients with CAI, is there evidence to suggest that an orthotic intervention will help improve postural control? The literature was searched for studies of level 2 evidence or higher that investigated the effects of foot orthotics on postural control in patients with CAI. The search of the literature produced 5 possible studies for inclusion; 2 studies met the inclusion criteria and were included. One randomized controlled trial and 1 outcomes study were included. Foot orthotics appear to be effective at improving postural control in patients with CAI. There is moderate evidence to support the use of foot orthotics in the treatment of CAI to help improve postural control. There is grade B evidence that foot orthotics help improve postural control in people with CAI. The Centre of Evidence Based Medicine recommends a grade of B for level 2 evidence with consistent findings.

  2. Bilateral Arthrodesis of the Ankle Joint: Self-Reported Outcomes in 35 Patients From the Swedish Ankle Registry.

    Science.gov (United States)

    Henricson, Anders; Kamrad, Ilka; Rosengren, Björn; Carlsson, Åke

    Bilateral ankle arthrodesis is seldom performed, and results concerning the outcome and satisfaction can only sparsely be found in published studies. We analyzed the data from 35 patients who had undergone bilateral ankle arthrodesis in the Swedish Ankle Registry using patient-reported generic and region-specific outcome measures. Of 36 talocrural arthrodeses and 34 tibio-talar-calcaneal arthrodeses, 6 ankles (9%) had undergone repeat arthrodesis because of nonunion. After a mean follow-up period of 47 ± 5 (range 12 to 194) months, the mean scores were as follows: self-reported foot and ankle score, 33 ± 10 (range 4 to 48); the EuroQol Group's EQ-5D ™ score, 0.67 ± 0.28 (range -0.11 to 1), the EuroQol Group's visual analog scale score, 70 ± 19 (range 20 to 95), 36-item Short Form Health Survey (SF-36) physical domain, 39 ± 11 (range 16 to 58); and SF-36 mental domain, 54 ± 14 (range 17 to 71). Patients with rheumatoid arthritis seemed to have similar self-reported foot and ankle scores but possibly lower EQ-5D ™ and SF-36 scores. Those with talocrural arthrodeses scored higher than did those with tibio-talar-calcaneal arthrodeses on the EQ5D ™ and SF-36 questionnaires (p = .03 and p = .04). In 64 of 70 ankles (91%), the patients were satisfied or very satisfied with the outcome. In conclusion, we consider bilateral ankle arthrodesis to be a reasonable treatment for symptomatic hindfoot arthritis, with high postoperative mid-term satisfaction and satisfactory scores on the patient-reported generic and region-specific outcome measures, when no other treatment option is available. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Differentiation between solid-ankle cushioned heel and energy storage and return prosthetic foot based on step-to-step transition cost.

    Science.gov (United States)

    Wezenberg, Daphne; Cutti, Andrea G; Bruno, Antonino; Houdijk, Han

    2014-01-01

    Decreased push-off power by the prosthetic foot and inadequate roll-over shape of the foot have been shown to increase the energy dissipated during the step-to-step transition in human walking. The aim of this study was to determine whether energy storage and return (ESAR) feet are able to reduce the mechanical energy dissipated during the step-to-step transition. Fifteen males with a unilateral lower-limb amputation walked with their prescribed ESAR foot (Vari-Flex, Ossur; Reykjavik, Iceland) and with a solid-ankle cushioned heel foot (SACH) (1D10, Ottobock; Duderstadt, Germany), while ground reaction forces and kinematics were recorded. The positive mechanical work on the center of mass performed by the trailing prosthetic limb was larger (33%, p = 0.01) and the negative work performed by the leading intact limb was lower (13%, p = 0.04) when walking with the ESAR foot compared with the SACH foot. The reduced step-to-step transition cost coincided with a higher mechanical push-off power generated by the ESAR foot and an extended forward progression of the center of pressure under the prosthetic ESAR foot. Results can explain the proposed improvement in walking economy with this kind of energy storing and return prosthetic foot.

  4. Leonardo da Vinci's foot: historical evidence of concept.

    Science.gov (United States)

    Jastifer, James R; Toledo-Pereyra, Luis H

    2012-10-01

    Leonardo da Vinci (1452-1519), world-renowned Italian renaissance master, is known for his contributions to, and broad interests in science and art. The objective of this work is to demonstrate the extent of his science by applying the use of his concepts to current models of foot and ankle mechanics. The art and science of Leonardo Da Vinci were extensively analyzed by reviewing his original drawings and hand written notebooks as well as their English translation. Current medical journals including the topics of foot, ankle, and biomechanics were reviewed for modern evidence and application of his concepts. The library of Michigan State University and the electronic library of the Royal Library at Windsor Castle were extensively utilized. From the depths of Santa Maria Nuova Hospital in Florence and Santo Spirito Hospital in Rome, through his commentary and anatomical drawings of around 30 cadaver dissections he performed, Leonardo da Vinci expressed his concept of foot and ankle anatomy and mechanics. He laid forth concepts, which vary little from current theories including those of proportion, statics and joint stability, sesamoid biomechanics, and structural support of the foot. Leonardo da Vinci, by combining an interest in anatomy and a gift of genius and artistic ability laid a foundation of foot and ankle anatomy and mechanics that have been applied in modern clinical sciences. Leonardo in this way made important contributions to the practice of foot and ankle orthopedics.

  5. Clinically assessed mediolateral knee motion: impact on gait

    DEFF Research Database (Denmark)

    Thorlund, Jonas Bloch; Creaby, Mark W; Simic, Milena

    2011-01-01

    Mediolateral knee movement can be assessed visually with clinical tests. A knee-medial-to-foot position is associated with an increased risk of knee injuries and pathologies. However, the implications of such findings on daily tasks are not well understood. The aim of this study was to investigat...... if a knee-medial-to-foot position assessed during a clinical test was associated with altered hip and knee joint kinematics and knee joint kinetics during gait compared with those with a knee-over-foot position....

  6. The Relationship between Isokinetic Relative Torque of Hip, Knee and Ankle Joints and the Height of Guide Leg Jump in Young Men

    Directory of Open Access Journals (Sweden)

    Saeed Nikoukheslat

    2016-06-01

    Full Text Available Objective: The aim of this study was to investigate the relationship between isokinetic relative torques of hip, knee and ankle joints and the height of guide leg jump in young men. Methods: 27 college male athletes with mean age of 25±3.5 years, height 178.5±7.8 cm and weight of 75.7±10.7 kg voluntarily participated in this study. Isokinetic torque of hip, knee and ankle joints and the height of vertical jump were measured using BIODEX SYSTEM PRO 4 and digital vertical jumping tester systems respectively. Pearson correlation test at p<0.05 was used for statistical analysis. Results: Results showed that there were significant correlations between height of jump and hip joint flexion (p= 0.047 & r= 0.39 and extension (p= 0.003 & r= 0.55 torques of guide leg, hip joint extension torque of support leg (p= 0.020 & r=0.45 and knee joint flexion (p= 0.019 & r=0.45 and extension torques of support leg (p=0.006 & r=0.52. Conclusion: The results of this study show that flexion and extension torques of hip joint in guide leg and knee joint in support leg and also extension torque of hip joint in support leg have main effect on height of guide leg jump. Thus, in designing a specific training program for athletes in whom the nature of jump in their sports is guide leg jump, particular attention should be given to hip and knee joints strength.

  7. 40 CFR Table 2 to Subpart Wwww of... - Compliance Dates for New and Existing Reinforced Plastic Composites Facilities

    Science.gov (United States)

    2010-07-01

    ... Reinforced Plastic Composites Facilities 2 Table 2 to Subpart WWWW of Part 63 Protection of Environment...: Reinforced Plastic Composites Production Pt. 63, Subpt. WWWW, Table 2 Table 2 to Subpart WWWW of Part 63—Compliance Dates for New and Existing Reinforced Plastic Composites Facilities As required in §§ 63.5800 and...

  8. What Causes Ankle Swelling During Pregnancy - And What Can I do About it?

    Science.gov (United States)

    ... the ankles or calves. Some research suggests that foot massage and reflexology, which involves applying pressure to certain areas of the feet, hands and ears, might help decrease foot and ankle swelling during pregnancy. Also, swelling doesn' ...

  9. Ankle-foot orthoses in stroke: Effects on functional balance, weight-bearing asymmetry and the contribution of each lower limb to balance control

    NARCIS (Netherlands)

    Nikamp-Simons, Corien Diana Maria; van Asseldonk, Edwin H.F.; van der Kooij, Herman; Geurts, Alexander C.H.; Buurke, Jaap

    2009-01-01

    Background Ankle-foot orthoses are often provided to improve walking in stroke patients, although the evidence of effects on walking and balance control is still inconsistent. This could be caused by a lack of insight into the influence of orthoses on the underlying impairments. These impairments

  10. High Variability of Observed Weight Bearing During Standing Foot and Ankle Radiographs.

    Science.gov (United States)

    Miller, Christopher P; Ghorbanhoseini, Mohammad; Ehrlichman, Lauren K; Walley, Kempland C; Ghaheri, Azadeh; Kwon, John Y

    2017-06-01

    Weight-bearing radiographs are a critical component of evaluating foot and ankle pathology. An underlying assumption is that patients are placing 50% of their body weight on the affected foot during image acquisition. The accuracy of weight bearing during radiographs is unknown and, presumably, variable, which may result in uncertain ability of the resultant radiographs to appropriately portray the pathology of interest. Fifty subjects were tested. The percentage body weight through the foot of interest was measured at the moment of radiographic image acquisition. The subject was then instructed to bear "half [their] weight" prior to the next radiograph. The percentage body weight was calculated and compared to ideal 50% weight bearing. The mean percentage body weight in trial 1 and 2 was 45.7% ± 3.2% ( P = .012 compared to the 50% mark) and 49.2% ± 2.4%, respectively ( P = .428 compared to 50%). The mean absolute difference in percentage weight bearing compared to 50% in trials 1 and 2 was 9.3% ± 2.3% and 5.8% ± 1.8%, respectively ( P = .005). For trial 1, 18/50 subjects were within the "ideal" (45%-55%) range for weight bearing compared to 32/50 on trial 2 ( P = .005). In trial 1, 24/50 subjects had "appropriate" (>45%) weight bearing compared to 39/50 on trial 2 ( P = .002). There was substantial variability in the weight applied during radiograph acquisition. This study raises questions regarding the assumptions, reliability, and interpretation when evaluating weight-bearing radiographs. Level III, comparative study.

  11. Ankle and Midfoot Power During Walking and Stair Ascent in Healthy Adults.

    Science.gov (United States)

    DiLiberto, Frank E; Nawoczenski, Deborah A; Houck, Jeff

    2018-02-27

    Ankle power dominates forward propulsion of gait, but midfoot power generation is also important for successful push off. However, it is unclear if midfoot power generation increases or stays the same in response to propulsive activities that induce larger external loads and require greater ankle power. The purpose of this study was to examine ankle and midfoot power in healthy adults during progressively more demanding functional tasks. Multi-segment foot motion (tibia, calcaneus, forefoot) and ground reaction forces were recorded as participants (N=12) walked, ascended a standard step, and ascended a high step. Ankle and midfoot positive peak power and total power, and the proportion of midfoot to ankle total power were calculated. One-way repeated measures ANOVAs were conducted to evaluate differences across tasks. Main effects were found for ankle and midfoot peak and total powers (all p power (p = .331). Ankle and midfoot power significantly increased across each task. Midfoot power increased in proportion to ankle power and in congruence to the external load of a task. Study findings may serve to inform multi-segment foot modeling applications and internal mechanistic theories of normal and pathological foot function.

  12. Three-dimensional kinematics of the knee and ankle joints for three consecutive push-offs during ice hockey skating starts.

    Science.gov (United States)

    Lafontaine, Dany

    2007-09-01

    Little biomechanical research has been conducted recently on hockey skating despite the sport's worldwide appeal. One reason for this lack of biomechanical knowledge stems from the difficulty of collecting data. The lack of accuracy, the disputable realism of treadmills, and the large field of view required are some of the technical challenges that have to be overcome. The main objective of the current study was to improve our knowledge of the joint kinematics during the skating stroke. A second objective was to improve the data collection system we developed and the third was to establish if a kinematic progression exists in the hockey skating stroke similar to that in speed skating. Relative motions at the knee and ankle joints were computed using a joint coordinate system approach. The differences at the knee joints in push-offs indicated that the skating skill was progressively changing with each push-off. The relative stability of the ankle angles can be attributed to the design of the skate boots, which have recently become very rigid. Further research on ice hockey skating is warranted and should include more skaters and investigate the effect various starting strategies and variations in equipment have on skaters' performance.

  13. The ankle-foot orthosis improves balance and reduces fall risk of chronic spastic hemiparetic patients.

    Science.gov (United States)

    Cakar, E; Durmus, O; Tekin, L; Dincer, U; Kiralp, M Z

    2010-09-01

    Ankle foot orthoses (AFO) are commonly used orthotic device in order to restore the ankle foot function and to improve the balance and gait in post-stroke hemiparetic patients. However, there remain some discussions about their effectiveness on long term hemiparetic patients who had mild to moderate spasticity. To investigate the relative effect of prefabricated thermoplastic posterior leaf spring AFO (PLS-AFO) on balance and fall risk. A cross-over interventional study The Department of PMR of a tertiary hospital. Twenty-five chronic post-stroke long duration hemiparetic patients who had Ashworth grade 1-2 spasticity at affected calf muscles and lower limb Brunnstrom stage 2-3 and also able to walk independently without an assistive device. Berg Balance Scale (BERG), and the postural stability test (PST) and the fall risk test (FRT) of Biodex balance systems were used for the assessments. All of the patients were assessed with AFO and without AFO. All assessments were made with footwear. The mean post-stroke duration was 20,32±7,46 months. The BERG scores were 42,12±9,05 without AFO and 47,52±7,77 with AFO; the overall stability scores of FRT were 3,35±1,97 without AFO and 2,69±1,65 with AFO (Pbalance and provide fall risk reduction in chronic post-stroke ambulatory hemiparetic patients who had mild to moderate spasticity on their affected lower limb. These results encourage the usage of AFO on long duration hemiparetic patients in order to provide better balance and lesser fall risk.

  14. Electromagnetic configurable architectures for assessment of Carbon Fiber Reinforced Plastics

    Directory of Open Access Journals (Sweden)

    Steigmann Rozina

    2017-01-01

    Full Text Available Carbon Fiber Reinforced Plastics are used in most wide domains due their low density, lack of mechanical fatigue phenomena and high strength–to weight ratio. From electromagnetic point of view, Carbon Fiber Reinforced Plastics structure represents an inhomogeneous structure of electric conductive fibers embedded into a dielectric material, thus an electromagnetic configurable architecture can be used to evaluate above mentioned defects. The paper proposes a special sensor, send receiver type and the obtaining of electromagnetic image by post-processing each coil signals in each point of scanning, using a sub-encoding image reconstruction algorithm and super-resolution procedures. The layout of fibers can be detected interrogating only diagonal reception coils.

  15. Efficient foot motor control by Neymar’s brain

    Directory of Open Access Journals (Sweden)

    Eiichi eNaito

    2014-08-01

    Full Text Available How very long-term (over many years motor skill training shapes internal motor representation remains poorly understood. We provide valuable evidence that the football brain of Neymar da Silva Santos Júnior (the Brasilian footballer recruits very limited neural resources in the motor-cortical foot regions during foot movements. We scanned his brain activity with a 3-tesla functional magnetic resonance imaging (fMRI while he rotated his right ankle at 1Hz. We also scanned brain activity when three other age-controlled professional footballers, two top-athlete swimmers and one amateur footballer performed the identical task. A comparison was made between Neymar’s brain activity with that obtained from the others. We found activations in the left medial-wall foot motor regions during the foot movements consistently across all participants. However, the size and intensity of medial-wall activity was smaller in the four professional footballers than in the three other participants, despite no difference in amount of foot movement. Surprisingly, the reduced recruitment of medial-wall foot motor regions became apparent in Neymar. His medial-wall activity was smallest among all participants with absolutely no difference in amount of foot movement. Neymar may efficiently control given foot movements probably by largely conserving motor-cortical neural resources. We discuss this possibility in terms of over-years motor skill training effect, use-dependent plasticity, and efficient motor control.

  16. The Motor and the Brake of the Trailing Leg in Human Walking: Leg Force Control Through Ankle Modulation and Knee Covariance

    Science.gov (United States)

    Toney, Megan E.; Chang, Young-Hui

    2016-01-01

    Human walking is a complex task, and we lack a complete understanding of how the neuromuscular system organizes its numerous muscles and joints to achieve consistent and efficient walking mechanics. Focused control of select influential task-level variables may simplify the higher-level control of steady state walking and reduce demand on the neuromuscular system. As trailing leg power generation and force application can affect the mechanical efficiency of step-to-step transitions, we investigated how joint torques are organized to control leg force and leg power during human walking. We tested whether timing of trailing leg force control corresponded with timing of peak leg power generation. We also applied a modified uncontrolled manifold analysis to test whether individual or coordinated joint torque strategies most contributed to leg force control. We found that leg force magnitude was adjusted from step-to-step to maintain consistent leg power generation. Leg force modulation was primarily determined by adjustments in the timing of peak ankle plantar-flexion torque, while knee torque was simultaneously covaried to dampen the effect of ankle torque on leg force. We propose a coordinated joint torque control strategy in which the trailing leg ankle acts as a motor to drive leg power production while trailing leg knee torque acts as a brake to refine leg power production. PMID:27334888

  17. Strain gradient plasticity effects in whisker-reinforced metals

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof

    2003-01-01

    A metal reinforced by fibers in the micron range is studied using the strain gradient plasticity theory of Fleck and Hutchinson (J. Mech. Phys. Solids 49 (2001) 2245). Cell-model analyses are used to study the influence of the material length parameters numerically, for both a single parameter...

  18. 99mTc-HDP SPECT-CT Aids Localization of Joint Injections in Degenerative Joint Disease of the Foot and Ankle.

    Science.gov (United States)

    Parthipun, Arum; Moser, Joanna; Mok, Wing; Paramithas, Anton; Hamilton, Paul; Sott, Andrea Helene

    2015-08-01

    Pain relating to degenerative joint disease within the foot and ankle can be difficult to localize with clinical examination alone due to the complex anatomy of the joints. The aim of this study was to determine whether single-photon emission computed tomography combined with conventional computed tomography (SPECT-CT) could be used to localize the site of degenerative joint disease for intra-articular injection and thereby improve the clinical success of the procedure. A prospective study was performed involving 203 patients who had undergone triple-phase (99m)Tc-hydroxymethylene diphosphonate bone scans with SPECT-CT of the foot and ankle for degenerative joint disease. Fifty-two patients went on to have joint injections for degenerative joint disease, with clinical follow-up. Correlation with the clinical diagnosis and the outcome of intra-articular injections with 0.5% bupivacaine and 80 mg of Depo-Medrone was performed. A successful outcome was determined by an improvement in the visual analog pain score of at least 50%. In 19 (37%) patients, the site of degenerative joint disease determined by SPECT-CT differed from the initial clinical assessment and resulted in a change in management. Overall, 46 (88%) patients showed an improvement in symptoms. The study demonstrated a high clinical success rate for SPECT-CT-guided joint injections. The technique was useful in localizing degenerative joint disease of the ankle, hindfoot, and midfoot as an adjunct to clinical examination. Level IV, case series. © The Author(s) 2015.

  19. Comparison of SPECT/CT and MRI in diagnosing symptomatic lesions in ankle and foot pain patients: diagnostic performance and relation to lesion type.

    Science.gov (United States)

    Ha, Seunggyun; Hong, Sung Hwan; Paeng, Jin Chul; Lee, Dong Yeon; Cheon, Gi Jeong; Arya, Amitabh; Chung, June-Key; Lee, Dong Soo; Kang, Keon Wook

    2015-01-01

    The purpose of this study was to compare the diagnostic performance of SPECT/CT and MRI in patients with ankle and foot pain, with regard to the lesion types. Fifty consecutive patients with ankle and foot pain, who underwent 99mTc-MDP SPECT/CT and MRI, were retrospectively enrolled in this study. Symptomatic lesions were determined based on clinical examination and response to treatment. On MRI and SPECT/CT, detected lesions were classified as bone, ligament/tendon, and joint lesions. Uptake on SPECT/CT was assessed using a 4-grade system. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SPECT/CT and MRI were evaluated in all detected lesions and each lesion type. Diagnostic value of uptake grade was analyzed using receiver-operating characteristics (ROC) curve analysis, and diagnostic performance was compared using Chi-square or McNemar tests. In overall lesions, the sensitivity, PPV and NPV of SPECT/CT for symptomatic lesions were 93%, 56%, 91%, and they were 98%, 48%, 95% for MRI. There was no significant difference between SPECT/CT and MRI. However, the specificity of SPECT/CT was significantly higher than that of MRI (48% versus 24%, P = 0.016). Uptake grade on SPECT/CT was significantly higher in symptomatic lesions (P diagnostic performance for symptomatic lesions in ankle and foot pain patients. SPECT/CT and MRI exhibit different diagnostic specificity in different lesion types. SPECT/CT may be used as a complementary imaging method to MRI for enhancing diagnostic specificity.

  20. Publication rates of poster presentations at the American College of Foot and Ankle Surgeons annual scientific conference between 1999 and 2008.

    Science.gov (United States)

    Abicht, Bradley P; Donnenwerth, Michael P; Borkosky, Sara L; Plovanich, Elizabeth J; Roukis, Thomas S

    2012-01-01

    Publication is the desired end point of scientific research. Ultimately, it is desired that research presented in poster format at a scientific conference will be developed into a report and become published in a peer-reviewed scientific journal. Moreover, poster presentations of research studies are often referenced and, as a result, influence treatment care plans. No data exist for the actual publication rate of podiatric foot and ankle surgery poster presentations. Therefore, the objective of the present study was to determine the actual publication rates of poster presentations at the American College of Foot and Ankle Surgeons (ACFAS) annual scientific conference (ASC) during a 10-year period. Print or electronic media for the ACFAS ASC official program from 1999 to 2008 were obtained. Each year's official program was manually searched for any poster presentation and, when identified, the authors and title were individually searched using Internet-based search engines to determine whether a poster presentation had been followed by publication. Of the 825 posters, 198 (24%) poster presentations were ultimately published in 1 of 32 medical journals within a weighted mean of 17.6 months. Of the 32 journals, 25 (78.1%) represented peer-reviewed journals. The publication rate of poster presentations at the ACFAS ASC was less than that of oral manuscripts presented at the same meeting during the same period and was also less than the orthopedic subspecialty poster presentation publication rates. Therefore, attendees of the ACFAS ASC should be aware that only a few of the posters presented at the ACFAS ASC will be valid because they will not survive the rigors of publication 76% of the time. Additionally, more stringent selection criteria should be used so that the selected poster presentations can ultimately withstand the publication process. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Initial foot contact and related kinematics affect impact loading rate in running.

    Science.gov (United States)

    Breine, Bastiaan; Malcolm, Philippe; Van Caekenberghe, Ine; Fiers, Pieter; Frederick, Edward C; De Clercq, Dirk

    2017-08-01

    This study assessed kinematic differences between different foot strike patterns and their relationship with peak vertical instantaneous loading rate (VILR) of the ground reaction force (GRF). Fifty-two runners ran at 3.2 m · s -1 while we recorded GRF and lower limb kinematics and determined foot strike pattern: Typical or Atypical rearfoot strike (RFS), midfoot strike (MFS) of forefoot strike (FFS). Typical RFS had longer contact times and a lower leg stiffness than Atypical RFS and MFS. Typical RFS showed a dorsiflexed ankle (7.2 ± 3.5°) and positive foot angle (20.4 ± 4.8°) at initial contact while MFS showed a plantar flexed ankle (-10.4 ± 6.3°) and more horizontal foot (1.6 ± 3.1°). Atypical RFS showed a plantar flexed ankle (-3.1 ± 4.4°) and a small foot angle (7.0 ± 5.1°) at initial contact and had the highest VILR. For the RFS (Typical and Atypical RFS), foot angle at initial contact showed the highest correlation with VILR (r = -0.68). The observed higher VILR in Atypical RFS could be related to both ankle and foot kinematics and global running style that indicate a limited use of known kinematic impact absorbing "strategies" such as initial ankle dorsiflexion in MFS or initial ankle plantar flexion in Typical RFS.

  2. Effect of Acute Alterations in Foot Strike Patterns during Running on Sagittal Plane Lower Limb Kinematics and Kinetics.

    Science.gov (United States)

    Valenzuela, Kevin A; Lynn, Scott K; Mikelson, Lisa R; Noffal, Guillermo J; Judelson, Daniel A

    2015-03-01

    The purpose of this study was to determine the effect of foot strike patterns and converted foot strike patterns on lower limb kinematics and kinetics at the hip, knee, and ankle during a shod condition. Subjects were videotaped with a high speed camera while running a 5km at self-selected pace on a treadmill to determine natural foot strike pattern on day one. Preferred forefoot group (PFFG, n = 10) and preferred rear foot group (PRFG, n = 11) subjects were identified through slow motion video playback (n = 21, age = 22.8±2.2 years, mass = 73.1±14.5 kg, height 1.75 ± 0.10 m). On day two, subjects performed five overground run trials in both their natural and unnatural strike patterns while motion and force data were collected. Data were collected over two days so that foot strike videos could be analyzed for group placement purposes. Several 2 (Foot Strike Pattern -forefoot strike [FFS], rearfoot strike [RFS]) x 2 (Group - PFFG, PRFG) mixed model ANOVAs (p strike patterns during shod running can create alterations in certain lower limb kinematic and kinetic measures that are not dependent on the preferred foot strike pattern of the individual. This research also challenges the contention that the impact transient spike in the vertical ground reaction force curve is only present during a rear foot strike type of running gait. Key pointsFootstrike pattern changes should be individually considered and implemented based on individual histories/abilitiesForefoot strike patterns increase external dorsiflexion momentsRearfoot strike patterns increase external knee flexion momentsRecreational shod runners are able to mimic habitual mechanics of different foot strike patterns.

  3. The V sign in lateral talar process fractures: an experimental study using a foot and ankle model.

    Science.gov (United States)

    Jentzsch, Thorsten; Hasler, Anita; Renner, Niklas; Peterhans, Manuel; Sutter, Reto; Espinosa, Norman; Wirth, Stephan H

    2017-07-03

    Lateral talar process fractures (LTPF) are often missed on conventional radiographs. A positive V sign is an interruption of the contour of the LTP. It has been suggested, but not proven to be pathognomonic for LTPF. The objective was to study whether the V sign is pathognomonic for LTPF and if it can be properly assessed in different ankle positions and varying fracture types. An experimental study was conducted. Two investigators assessed lateral radiographs (n = 108) of a foot and ankle model. The exposure variables were different ankle positions and fracture types. The primary outcome was the correct detection of a V sign. The secondary outcomes were the detection of the V sign depending on ankle position and fracture type as well as the uncertainty. The interobserver agreement on the V sign and type of fracture were fair (κ = 0.35, 95% CI 0.18-0.53, p ankle position and fracture type showed significant better results with increasing inversion (p = 0.035 and p = 0.011) and type B fractures (p = 0.001 and p = 0.013). The V sign may not be pathognomonic and is not recommended as the only modality for the detection of LTPF. It is better visualized with inversion, but does not depend on plantar flexion or internal rotation. It is also better seen in type B fractures. It is difficult to detect and investigator-dependent. It may be helpful in a clinical setting to point into a direction, but a CT scan may be used if in doubt about a LTPF.

  4. Influence of a Viscoelastic Insole on Foot, Knee and Back Pain among Members of the United States Army Band

    Science.gov (United States)

    2010-07-13

    Attenuation of spinal transients at heel strike using viscoelastic heel insoles: an in vivo study. Preventive Medicine. 2004;39:351-354. 30...2009 – March 2010 A-4 35. Bender JA, Pierson JK, Kaplan HM, Johnson AJ. Factors affecting the occurrence of knee injuries . Journal of the...EPIDEMIOLOGICAL REPORT NO. 12-HF-97G010-09 INFLUENCE OF A VISCOELASTIC INSOLE ON FOOT, KNEE AND BACK PAIN AMONG MEMBERS

  5. Muscular activity and torque of the foot dorsiflexor muscles during decremental isometric test: A cross-sectional study.

    Science.gov (United States)

    Ruiz-Muñoz, Maria; González-Sánchez, Manuel; Martín-Martín, Jaime; Cuesta-Vargas, Antonio I

    2017-06-01

    To analyse the torque variation level that could be explained by the muscle activation (EMG) amplitude of the three major foot dorsiflexor muscles (tibialis anterior (TA), extensor digitorum longus (EDL), extensor hallucis longus (EHL)) during isometric foot dorsiflexion at different intensities. In a cross-sectional study, forty-one subjects performed foot dorsiflexion at 100%, 75%, 50% and 25% of maximal voluntary contractions (MVC) with the hip and knee flexed 90° and the ankle in neutral position (90° between leg and foot). Three foot dorsiflexions were performed for each intensity. Outcome variables were: maximum (100% MVC) and relative torque (75%, 50%, 25% MVC), maximum and relative EMG amplitude. A linear regression analysis was calculated for each intensity of the isometric foot dorsiflexion. The degree of torque variation (dependent variable) from the independent variables explain (EMG amplitude of the three major foot dorsiflexor muscles) the increases when the foot dorsiflexion intensity is increased, with values of R 2 that range from 0.194 (during 25% MVC) to 0.753 (during 100% MVC). The reliability of the outcome variables was excellent. The EMG amplitude of the three main foot dorsiflexors exhibited more variance in the dependent variable (torque) when foot dorsiflexion intensity increases. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. The health economics of ankle and foot sprains and fractures: A systematic review of English-language published papers. Part 1: Overview and critical appraisal.

    Science.gov (United States)

    Bielska, Iwona A; Wang, Xiang; Lee, Raymond; Johnson, Ana P

    2017-07-01

    Ankle and foot sprains and fractures are common injuries affecting many individuals, often requiring considerable and costly medical interventions. The objectives of this systematic review are to collect, assess, and critically appraise the published literature on the health economics of ankle and foot injury (sprain and fracture) treatment. A systematic literature review of Ovid MEDLINE, EMBASE, Cochrane DSR, ACP Journal Club, AMED, Ovid Healthstar, and CINAHL was conducted for English-language studies on the costs of treating ankle and foot sprains and fractures published from January 1980 to December 2014. Two reviewers assessed the articles for study quality and abstracted data. The literature search identified 2047 studies of which 32 were analyzed. A majority of the studies were published in the last decade. A number of the studies did not report full economic information, including the sources of the direct and indirect costs, as suggested in the guidelines. The perspective used in the analysis was missing in numerous studies, as was the follow-up time period of participants. Only five of the studies undertook a sensitivity analysis which is required whenever there are uncertainties regarding cost data. This systematic review found that publications do not consistently report on the components of health economics methodology, which in turn limits the quality of information. Future studies undertaking economic evaluations should ensure that their methods are transparent and understandable so as to yield accurate interpretation for assistance in forthcoming economic evaluations and policy decision-making. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Effects of joint alignment and type on mechanical properties of thermoplastic articulated ankle-foot orthosis.

    Science.gov (United States)

    Gao, Fan; Carlton, William; Kapp, Susan

    2011-06-01

    Articulated or hinged ankle-foot orthosis (AFO) allow more range of motion. However, quantitative investigation on articulated AFO is still sparse. The objective of the study was to quantitatively investigate effects of alignment and joint types on mechanical properties of the thermoplastic articulated AFO. Tamarack dorsiflexion assist flexure joints with three durometers (75, 85 and 95) and free motion joint were tested. The AFO joint was aligned with the center of the motor shaft (surrogate ankle joint), 10 mm superior, inferior, anterior and posterior with respect to the motor shaft center. The AFO was passively moved from 20° plantar flexion to 15° dorsiflexion at a speed of 10°/s using a motorized device. Mechanical properties including index of hysteresis, passive resistance torque and quasi-static stiffness (at neutral, 5°, 10° and 15° in plantar flexion) were quantified. Significant effects of joint types and joint alignment on the mechanical properties of an articulated thermoplastic AFO were revealed. Specifically, center alignment showed minimum resistance and stiffness while anterior and posterior alignment showed significantly higher resistance and stiffness. The dorsiflexion assist torques at neutral position ranged from 0.69 ± 0.09 to 1.88 ± 0.10 Nm. Anterior and posterior alignment should be avoided as much as possible. The current study suggested that anterior and posterior alignment be avoided as much as possible in clinical practice due to potential skin irritation and increase in stress around the ankle joint.

  8. An Overview of Internal and External Fixation Methods for the Diabetic Charcot Foot and Ankle.

    Science.gov (United States)

    Ramanujam, Crystal L; Zgonis, Thomas

    2017-01-01

    Diabetic Charcot neuroarthropathy (DCN) of the foot and ankle is a challenging disease with regard to clinical presentation, pathogenesis, and prognosis. Its surgical management is equally difficult to interpret based on the wide array of options available. In the presence of an ulceration or concomitant osteomyelitis, internal fixation by means of screws, plates, or intramedullary nailing needs to be avoided when feasible. External fixation becomes a great surgical tool when managing DCN with concomitant osteomyelitis. This article describes internal and external fixation methods along with available literature to enlighten surgeons faced with treating this complex condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Validation of the translated Oxford ankle foot questionnaire in 82 Danish children aged between five and 16 years.

    Science.gov (United States)

    Martinkevich, P; Møller-Madsen, B; Gottliebsen, M; Kjeldgaard Pedersen, L; Rahbek, O

    2015-03-01

    We present the validation of a translation into Danish of the Oxford ankle foot questionnaire (OxAFQ). We followed the Isis Pros guidelines for translation and pilot-tested the questionnaire on ten children and their parents. Following modifications we tested the validity of the final questionnaire on 82 children (36 boys and 45 girls) with a mean age of 11.7 years (5.5 to 16.0) and their parents. We tested the reliability (repeatability (test-retest), child-parent agreement, internal consistency), feasibility (response rate, time to completion, floor and ceiling effects) and construct validity. The generic child health questionnaire was used for comparison. We found good internal consistency for the physical and the school and play domains, but lower internal consistency for the emotional domain. Overall, good repeatability was found within children and parents as well as agreement between children and parents. The OxAFQ was fast and easy to complete, but we observed a tendency towards ceiling effects in the school and play and emotional domains. To our knowledge this is the first independent validation of the OxAFQ in any language. We found it valid and feasible for use in the clinic to assess the impact on children's lives of foot and/or ankle disorders. It is a valuable research tool. ©2015 The British Editorial Society of Bone & Joint Surgery.

  10. Driving a modified car: a simple but unexploited adjunct in the management of patients with chronic right sided foot and ankle pain.

    Science.gov (United States)

    Jones, Carl; Abbassian, Ali; Trompeter, Alex; Solan, Matthew

    2010-12-01

    Driving is important in maintaining independence. Limb pain can significantly limit this ability. Automatic vehicles can restore independence to people with left lower or upper limb disability but those with right-sided pathology are disadvantaged in this respect. This is despite the fact that numerous centers across the UK specialize in modifying automatic cars such that they can be driven solely with the use of the left foot. The knowledge of this amongst patients and health professionals is lacking. In this study we aim to confirm this fact and discuss the legal and practical aspects of driving a modified car. We used patients who had undergone right-sided ankle and hind foot fusions or ankle replacements, as we believed they would have had a long period of right-sided leg pain that may have affected their driving ability. A consecutive series was identified from operative records over a 2 year period and patients contacted by telephone. We identified 33 patients, of these 22 were available for telephonic interview. The average duration of right leg disability was 7.5 years. All responders had seen at least two healthcare professionals but car modification had never been discussed at any stage. Only 3 were aware of such modifications and of these all had been informed by sources outside the health service. The availability of right to left modification of automatic cars is not widely known by patients and healthcare professionals alike with potential benefits of this simple adjunct not being exploited. More needs to be done to generate awareness of its existence as it may have a significant impact on patient independence. Copyright © 2009 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  11. Durability Characteristics Analysis of Plastic Worm Wheel with Glass Fiber Reinforced Polyamide

    OpenAIRE

    Kim, Gun-Hee; Lee, Jeong-Won; Seo, Tae-Il

    2013-01-01

    Plastic worm wheel is widely used in the vehicle manufacturing field because it is favorable for weight lightening, vibration and noise reduction, as well as corrosion resistance. However, it is very difficult for general plastics to secure the mechanical properties that are required for vehicle gears. If the plastic resin is reinforced by glass fiber in the fabrication process of plastic worm wheel, it is possible to achieve the mechanical properties of metallic material levels. In this stud...

  12. The Effect of Backpack Load Carriage on the Kinetics and Kinematics of Ankle and Knee Joints During Uphill Walking.

    Science.gov (United States)

    Lee, Jinkyu; Yoon, Yong-Jin; Shin, Choongsoo S

    2017-12-01

    The purpose of this study was to investigate the effect of load carriage on the kinematics and kinetics of the ankle and knee joints during uphill walking, including joint work, range of motion (ROM), and stance time. Fourteen males walked at a self-selected speed on an uphill (15°) slope wearing military boots and carrying a rifle in hand without a backpack (control condition) and with a backpack. The results showed that the stance time significantly decreased with backpack carriage (p < .05). The mediolateral impulse significantly increased with backpack carriage (p < .05). In the ankle joints, the inversion-eversion, and dorsi-plantar flexion ROM in the ankle joints increased with backpack carriage (p < .05). The greater dorsi-plantar flexion ROM with backpack carriage suggested 1 strategy for obtaining high plantar flexor power during uphill walking. The result of the increased mediolateral impulse and inversion-eversion ROM in the ankle joints indicated an increase in body instability caused by an elevated center of mass with backpack carriage during uphill walking. The decreased stance time indicated that an increase in walking speed could be a compensatory mechanism for reducing the instability of the body during uphill walking while carrying a heavy backpack.

  13. The influence of push-off timing in a robotic ankle-foot prosthesis on the energetics and mechanics of walking

    OpenAIRE

    Malcolm, Philippe; Quesada, Roberto E; Caputo, Joshua M; Collins, Steven H

    2015-01-01

    Background Robotic ankle-foot prostheses that provide net positive push-off work can reduce the metabolic rate of walking for individuals with amputation, but benefits might be sensitive to push-off timing. Simple walking models suggest that preemptive push-off reduces center-of-mass work, possibly reducing metabolic rate. Studies with bilateral exoskeletons have found that push-off beginning before leading leg contact minimizes metabolic rate, but timing was not varied independently from pus...

  14. Mechanical characterization and validation of poly (methyl methacrylate)/multi walled carbon nanotube composite for the polycentric knee joint.

    Science.gov (United States)

    Arun, S; Kanagaraj, S

    2015-10-01

    Trans femoral amputation is one of the most uncomfortable surgeries in patient׳s life, where the prosthesis consisting of a socket, knee joint, pylon and foot is used to do the walking activities. The artificial prosthetic knee joint imitates the functions of human knee to achieve the flexion-extension for the above knee amputee. The objective of present work is to develop a light weight composite material for the knee joint to reduce the metabolic cost of an amputee. Hence, an attempt was made to study the mechanical properties of multi walled carbon nanotubes (MWCNT) reinforced Poly (methyl methacrylate) (PMMA) prepared through melt mixing technique and optimize the concentration of reinforcement. The PMMA nanocomposites were prepared by reinforcing 0, 0.1, 0.2, 0.25, 0.3 and 0.4 wt% of MWCNT using injection moulding machine via twin screw extruder. It is observed that the tensile and flexural strength of PMMA, which were studied as per ASTM D638 and D790, respectively, were increased by 32.9% and 26.3% till 0.25 wt% reinforcement of MWCNT. The experimental results of strength and modulus were compared with theoretical prediction, where a good correlation was noted. It is concluded that the mechanical properties of PMMA were found to be increased to maximum at 0.25 wt% reinforcement of MWCNT, where the Pukanszky model and modified Halpin-Tsai model are suggested to predict the strength and modulus, respectively, of the PMMA/MWCNT composite, which can be opted as a suitable materiel for the development of polycentric knee joint. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Diagnostic accuracy of clinical decision rules to exclude fractures in acute ankle injuries : systematic review and meta-analysis

    NARCIS (Netherlands)

    Barelds, Ingrid; Krijnen, Wim P; van de Leur, Johannes P; van der Schans, Cees P; Goddard, Robert J

    BACKGROUND: Ankle decision rules are developed to expedite patient care and reduce the number of radiographs of the ankle and foot. Currently, only three systematic reviews have been conducted on the accuracy of the Ottawa Ankle and Foot Rules (OAFR) in adults and children. However, no systematic

  16. The effect of ankle joint immobilization on lower limb venous flow.

    Science.gov (United States)

    Craik, Johnathan D; Clark, Amanda; Hendry, James; Sott, Andrea H; Hamilton, Paul D

    2015-01-01

    Below-knee cast immobilization is associated with an increased risk of developing deep vein thrombosis secondary to venous stasis. We investigated the effect of weight-bearing in a below-knee cast or pneumatic walking boot on lower limb venous blood flow. Duplex ultrasonography was used to measure venous blood flow in the popliteal vein of 10 healthy volunteers. Venous blood flow was measured while at rest, ambulating non-weight-bearing, partial weight-bearing, and full weight-bearing. Measurements were performed without ankle joint immobilization, with the ankle immobilized in a neutral cast, and with the ankle immobilized in a pneumatic walking boot in both neutral and equinus. There was no significant reduction in venous blood flow measurements between full weight-bearing without ankle joint immobilization and full weight-bearing in a neutral cast or neutral pneumatic walking boot. However, venous blood flow was reduced when partial weight-bearing (50%) and when full weight-bearing in a pneumatic walking boot in equinus. These results demonstrate that venous blood flow returned to normal levels when the subjects were permitted to fully bear weight in below-knee casts or walking boots, provided that the ankle joint was not in equinus. Weight-bearing status and ankle joint position should be appreciated during decisions for the provision of chemical thromboprophylaxis. © The Author(s) 2014.

  17. Reinforced Plastic Composites Production: National Emission Standards for Hazardous Air Pollutants

    Science.gov (United States)

    National emissions standards for hazardous air pollutants for reinforced plastic composites production facilities. Regulates production and ancillary processes used to manufacture products with thermoset resins and gel coats.

  18. Spontaneous resolution of posterior ankle joint loose bodies after total ankle replacement: A case report.

    Science.gov (United States)

    Lee, Raymond P; Cheng, Sally H S

    2017-06-01

    Late stage ankle osteoarthritis often presents with debilitating pain. It is common to find osteophytes and loose body formation around the joint. Total ankle arthroplasty can preserve joint mobility and pain relieve for such patient. However, when trying to remove the osteophytes and loose bodies at the posterior ankle joint, there is risk of damaging posterior structures such as the neurovascular bundle during the procedure. We are presenting a case where the posterior loose bodies remained untouched during the operation, and patient showed spontaneous resolution of the lesions with time. Patient enjoyed good function outcome after the surgery. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  19. Expecting ankle tilts and wearing an ankle brace influence joint control in an imitated ankle sprain mechanism during walking.

    Science.gov (United States)

    Gehring, Dominic; Wissler, Sabrina; Lohrer, Heinz; Nauck, Tanja; Gollhofer, Albert

    2014-03-01

    A thorough understanding of the functional aspects of ankle joint control is essential to developing effective injury prevention. It is of special interest to understand how neuromuscular control mechanisms and mechanical constraints stabilize the ankle joint. Therefore, the aim of the present study was to determine how expecting ankle tilts and the application of an ankle brace influence ankle joint control when imitating the ankle sprain mechanism during walking. Ankle kinematics and muscle activity were assessed in 17 healthy men. During gait rapid perturbations were applied using a trapdoor (tilting with 24° inversion and 15° plantarflexion). The subjects either knew that a perturbation would definitely occur (expected tilts) or there was only the possibility that a perturbation would occur (potential tilts). Both conditions were conducted with and without a semi-rigid ankle brace. Expecting perturbations led to an increased ankle eversion at foot contact, which was mediated by an altered muscle preactivation pattern. Moreover, the maximal inversion angle (-7%) and velocity (-4%), as well as the reactive muscle response were significantly reduced when the perturbation was expected. While wearing an ankle brace did not influence muscle preactivation nor the ankle kinematics before ground contact, it significantly reduced the maximal ankle inversion angle (-14%) and velocity (-11%) as well as reactive neuromuscular responses. The present findings reveal that expecting ankle inversion modifies neuromuscular joint control prior to landing. Although such motor control strategies are weaker in their magnitude compared with braces, they seem to assist ankle joint stabilization in a close-to-injury situation. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Recovery From a First-Time Lateral Ankle Sprain and the Predictors of Chronic Ankle Instability: A Prospective Cohort Analysis.

    Science.gov (United States)

    Doherty, Cailbhe; Bleakley, Chris; Hertel, Jay; Caulfield, Brian; Ryan, John; Delahunt, Eamonn

    2016-04-01

    Impairments in motor control may predicate the paradigm of chronic ankle instability (CAI) that can develop in the year after an acute lateral ankle sprain (LAS) injury. No prospective analysis is currently available identifying the mechanisms by which these impairments develop and contribute to long-term outcome after LAS. To identify the motor control deficits predicating CAI outcome after a first-time LAS injury. Cohort study (diagnosis); Level of evidence, 2. Eighty-two individuals were recruited after sustaining a first-time LAS injury. Several biomechanical analyses were performed for these individuals, who completed 5 movement tasks at 3 time points: (1) 2 weeks, (2) 6 months, and (3) 12 months after LAS occurrence. A logistic regression analysis of several "salient" biomechanical parameters identified from the movement tasks, in addition to scores from the Cumberland Ankle Instability Tool and the Foot and Ankle Ability Measure (FAAM) recorded at the 2-week and 6-month time points, were used as predictors of 12-month outcome. At the 2-week time point, an inability to complete 2 of the movement tasks (a single-leg drop landing and a drop vertical jump) was predictive of CAI outcome and correctly classified 67.6% of cases (sensitivity, 83%; specificity, 55%; P = .004). At the 6-month time point, several deficits exhibited by the CAI group during 1 of the movement tasks (reach distances and sagittal plane joint positions at the hip, knee and ankle during the posterior reach directions of the Star Excursion Balance Test) and their scores on the activities of daily living subscale of the FAAM were predictive of outcome and correctly classified 84.8% of cases (sensitivity, 75%; specificity, 91%; P < .001). An inability to complete jumping and landing tasks within 2 weeks of a first-time LAS and poorer dynamic postural control and lower self-reported function 6 months after a first-time LAS were predictive of eventual CAI outcome. © 2016 The Author(s).

  1. 40 CFR 63.5795 - How do I know if my reinforced plastic composites production facility is a new affected source or...

    Science.gov (United States)

    2010-07-01

    ... for Hazardous Air Pollutants: Reinforced Plastic Composites Production What This Subpart Covers § 63.5795 How do I know if my reinforced plastic composites production facility is a new affected source or an existing affected source? (a) A reinforced plastic composites production facility is a new...

  2. Influence of Elastic Bandage and Neoprene Ankle Support on Ankle Position Sense and Pain in Subjects with Ankle Sprain (Grade I & II

    Directory of Open Access Journals (Sweden)

    Basir Majdoleslami

    2004-06-01

    Full Text Available Objective: to investigate whether a neoprene ankle support and elastic bandage around the ankle joint of subjects with ankle sprain (grade I&II would , in short term (a reduce pain (b improve ankle joint position sense and comparison of their effect with each other if they have. Materials & Methods: In a semi-experimental study, 30 subjects (16men, 14 women, age between 16-52 with ankle sprain grade I&II. Subjects had to have at least 2cm from 10cm visual analogue scale (VAS of ankle pain for study entry. All patients were randomly assigned to either an elastic bandage or a neoprene ankle support. One week later they were assigned to the opposite selection. Joint position sense was assessed in the sitting position using an electrogoniometer and pain by VAS where 0cm equals no pain and 10 cm equals worst pain. ankle pain and JPS were assessed for each selection one week apart. During each visit assessment were performed at baseline and after 20 min of bandage/neoprene ankle support application. Results: the mean of scores for ankle variables JPS and VAS was taken and paired-t test and Wilcoxon signed rank test was employed to calculate the different between two trails. Neoprene ankle support had significant effect on ankle JPS (P=0.034. But elastic bandage had no effect (P=0.539. Both of them had significantly reduced ankle pain. (P=0.000  Conclusion: In subjects with both neoprene ankle support and elastic bandage reduced ankle pain with more effect of neoprene ankle support. Only the neoprene ankle support had effect on knee JPS.

  3. Ankle Fractures: The Operative Outcome

    Directory of Open Access Journals (Sweden)

    Ahmad Hafiz Z

    2011-03-01

    Full Text Available Ankle fractures are commonly seen in orthopaedic practice. This retrospective study of patients with ankle fractures who underwent surgical treatment in our institution from January 2000 to December 2003 was undertaken to analyze the common causes and patterns of ankle fractures; and the functional outcome of operative treatment for these fractures. Eighty patients were identified and reviewed. There were 65 male (81.3% and 15 female patients (18.7% with age ranging from 13 to 71 years old (mean, 32.3y. Common causes of ankle fractures were trauma (especially motor vehicle accidents, sports injuries and the osteoporotic bones in the elderly. Weber C (64.0% was the most common pattern of fracture at presentation. The most common operative treatment for ankle fractures was open reduction and internal fixation (73 patients, 91.2%. Excellent and good outcomes were achieved in 93.8% of cases when measured using the Olerud and Molander scoring system for foot and ankle. In conclusion, operative treatment for ankle fractures restores sufficient stability and allowed mobility of the ankle joint.

  4. Principles of brain plasticity in improving sensorimotor function of the knee and leg in healthy subjects

    DEFF Research Database (Denmark)

    Ageberg, Eva; Bjorkman, Anders; Rosen, Birgitta

    2009-01-01

    ABSTRACT: BACKGROUND: Principles of brain plasticity are used in the treatment of patients with functional limitations to improve sensorimotor function. Training is included in the treatment of knee injury to improve both patient-reported function and sensorimotor function. However, impairment...... in sensorimotor function often persists despite training. Therefore, it was suggested that training programs need to be more effective to improve sensorimotor function after knee injury. The aim of the current study was to investigate if principles of brain plasticity that have been successfully used on the hand...... age 26 years, range 19-34, 50% women) were randomized to temporary local cutaneous application of anesthetic (EMLA) (n=14) or placebo cream (n=14). Fifty grams of EMLA, or placebo, was applied on the leg 10 cm above and 10 cm below the center of patella, leaving the area around the knee without cream...

  5. Lateral trunk lean and medializing the knee as gait strategies for knee osteoarthritis

    NARCIS (Netherlands)

    Gerbrands, T. A.; Pisters, M. F.; Theeven, P. J R; Verschueren, S.; Vanwanseele, B.

    2017-01-01

    Objective To determine (1) if Medial Thrust or Trunk Lean reduces the knee adduction moment (EKAM) the most during gait in patients with medial knee osteoarthritis, (2) if the best overall strategy is the most effective for each patient and (3) if these strategies affect ankle and hip kinetics.

  6. Cosmetic Foot Surgery: Fashion's Pandora's Box

    Science.gov (United States)

    ... Fashion’s Pandora’s Box? A A A | Print | Share Cosmetic Foot Surgery: Fashion’s Pandora’s Box? Foot and ankle ... extreme and imprudent as it may sound, the cosmetic surgery craze is not just for faces anymore— ...

  7. Determination of Ankle and Metatarsophalangeal Stiffness During Walking and Jogging.

    Science.gov (United States)

    Mager, Fabian; Richards, Jim; Hennies, Malika; Dötzel, Eugen; Chohan, Ambreen; Mbuli, Alex; Capanni, Felix

    2018-05-29

    Forefoot stiffness has been shown to influence joint biomechanics. However, little or no data exists on metatarsophalangeal stiffness. Twenty-four healthy rearfoot strike runners were recruited from a staff and student population at the University of Central Lancashire. Five repetitions of shod, self-selected speed level walking and jogging were performed. Kinetic and kinematic data were collected using retro-reflective markers placed on the lower limb and foot, to create a three-segment foot model using the Calibrated Anatomical System Technique. Ankle and metatarsophalangeal moments and angles were calculated. Stiffness values were calculated using a linear best fit line of moment versus of angle plots. Paired t-tests were used to compare values between walking and jogging conditions. Significant differences were seen in ankle range of motion (ROM), but not in metatarsophalangeal ROM. Maximum moments were significantly greater in the ankle during jogging, but these were not significantly different at the metatarsophalangeal joint. Average ankle joint stiffness exhibited significantly lower stiffness when walking compared to jogging. However, the metatarsophalangeal joint exhibited significantly greater stiffness when walking compared to jogging. A greater understanding of forefoot stiffness may inform the development of footwear, prosthetic feet and orthotic devices, such as ankle-foot orthoses for walking and sporting activities.

  8. Assessment and management of patients with ankle injuries.

    Science.gov (United States)

    Walker, Jennie

    2014-08-19

    Foot and ankle injuries are common and can have a significant effect on an individual's daily activities. Nurses have an important role in the assessment, management, ongoing care and support of patients with ankle injuries. An understanding of the anatomy and physiology of the ankle enables nurses to identify significant injuries, which may result in serious complications, and communicate effectively with the multidisciplinary team to improve patient care and outcomes.

  9. Optimization of Recycled Glass Fibre-Reinforced Plastics Gear via Integration of the Taguchi Method and Grey Relational Analysis

    Science.gov (United States)

    Mizamzul Mehat, Nik; Syuhada Zakarria, Noor; Kamaruddin, Shahrul

    2018-03-01

    The increase in demand for industrial gears has resulted in the increase in usage of plastic-matrix composites particularly glass fibre-reinforced plastics as the gear materials. The usage of these synthetic fibers is to enhance the mechanical strength and the thermal resistance of the plastic gears. Nevertheless, the production of large quantities of these synthetic fibre-reinforced composites poses a serious threat to the ecosystem. Comprehending to this fact, the present work aimed at investigating the effects of incorporating recycled glass fibre-reinforced plastics in various compositions particularly on dimensional stability and mechanical properties of gear produced with diverse injection moulding processing parameters setting. The integration of Grey relational analysis (GRA) and Taguchi method was adopted to evaluate the influence of recycled glass fibre-reinforced plastics and variation in processing parameters on gear quality. From the experimental results, the blending ratio was found as the most influential parameter of 56.0% contribution in both improving tensile properties as well as in minimizing shrinkage, followed by mould temperature of 24.1% contribution and cooling time of 10.6% contribution. The results obtained from the aforementioned work are expected to contribute to accessing the feasibility of using recycled glass fibre-reinforced plastics especially for gear application.

  10. Foot deformities, function in the lower extremities, and plantar pressure in patients with diabetes at high risk to develop foot ulcers.

    Science.gov (United States)

    Tang, Ulla Hellstrand; Zügner, Roland; Lisovskaja, Vera; Karlsson, Jon; Hagberg, Kerstin; Tranberg, Roy

    2015-01-01

    Foot deformities, neuropathy, and dysfunction in the lower extremities are known risk factors that increase plantar peak pressure (PP) and, as a result, the risk of developing foot ulcers in patients with diabetes. However, knowledge about the prevalence of these factors is still limited. The aim of the present study was to describe the prevalence of risk factors observed in patients with diabetes without foot ulcers and to explore possible connections between the risk factors and high plantar pressure. Patients diagnosed with type 1 (n=27) or type 2 (n=47) diabetes (mean age 60.0±15.0 years) were included in this cross-sectional study. Assessments included the registration of foot deformities; test of gross function at the hip, knee, and ankle joints; a stratification of the risk of developing foot ulcers according to the Swedish National Diabetes Register; a walking test; and self-reported questionnaires including the SF-36 health survey. In-shoe PP was measured in seven regions of interests on the sole of the foot using F-Scan(®). An exploratory analysis of the association of risk factors with PP was performed. Neuropathy was present in 28 (38%), and 39 (53%) had callosities in the heel region. Low forefoot arch was present in 57 (77%). Gait-related parameters, such as the ability to walk on the forefoot or heel, were normal in all patients. Eighty percent had normal function at the hip and ankle joints. Gait velocity was 1.2±0.2 m/s. All patients were stratified to risk group 3. Hallux valgus and hallux rigidus were associated with an increase in the PP in the medial forefoot. A higher body mass index (BMI) was found to increase the PP at metatarsal heads 4 and 5. Pes planus was associated with a decrease in PP at metatarsal head 1. Neuropathy did not have a high association with PP. This study identified several potential risk factors for the onset of diabetic foot ulcers (DFU). Hallux valgus and hallux rigidus appeared to increase the PP under the medial

  11. Foot deformities, function in the lower extremities, and plantar pressure in patients with diabetes at high risk to develop foot ulcers

    Directory of Open Access Journals (Sweden)

    Ulla Hellstrand Tang

    2015-06-01

    Full Text Available Objective: Foot deformities, neuropathy, and dysfunction in the lower extremities are known risk factors that increase plantar peak pressure (PP and, as a result, the risk of developing foot ulcers in patients with diabetes. However, knowledge about the prevalence of these factors is still limited. The aim of the present study was to describe the prevalence of risk factors observed in patients with diabetes without foot ulcers and to explore possible connections between the risk factors and high plantar pressure. Patients and methods: Patients diagnosed with type 1 (n=27 or type 2 (n=47 diabetes (mean age 60.0±15.0 years were included in this cross-sectional study. Assessments included the registration of foot deformities; test of gross function at the hip, knee, and ankle joints; a stratification of the risk of developing foot ulcers according to the Swedish National Diabetes Register; a walking test; and self-reported questionnaires including the SF-36 health survey. In-shoe PP was measured in seven regions of interests on the sole of the foot using F-Scan®. An exploratory analysis of the association of risk factors with PP was performed. Results: Neuropathy was present in 28 (38%, and 39 (53% had callosities in the heel region. Low forefoot arch was present in 57 (77%. Gait-related parameters, such as the ability to walk on the forefoot or heel, were normal in all patients. Eighty percent had normal function at the hip and ankle joints. Gait velocity was 1.2±0.2 m/s. All patients were stratified to risk group 3. Hallux valgus and hallux rigidus were associated with an increase in the PP in the medial forefoot. A higher body mass index (BMI was found to increase the PP at metatarsal heads 4 and 5. Pes planus was associated with a decrease in PP at metatarsal head 1. Neuropathy did not have a high association with PP. Conclusions: This study identified several potential risk factors for the onset of diabetic foot ulcers (DFU. Hallux valgus

  12. Reliability of sagittal plane hip, knee, and ankle joint angles from a single frame of video data using the GAITRite camera system.

    Science.gov (United States)

    Ross, Sandy A; Rice, Clinton; Von Behren, Kristyn; Meyer, April; Alexander, Rachel; Murfin, Scott

    2015-01-01

    The purpose of this study was to establish intra-rater, intra-session, and inter-rater, reliability of sagittal plane hip, knee, and ankle angles with and without reflective markers using the GAITRite walkway and single video camera between student physical therapists and an experienced physical therapist. This study included thirty-two healthy participants age 20-59, stratified by age and gender. Participants performed three successful walks with and without markers applied to anatomical landmarks. GAITRite software was used to digitize sagittal hip, knee, and ankle angles at two phases of gait: (1) initial contact; and (2) mid-stance. Intra-rater reliability was more consistent for the experienced physical therapist, regardless of joint or phase of gait. Intra-session reliability was variable, the experienced physical therapist showed moderate to high reliability (intra-class correlation coefficient (ICC) = 0.50-0.89) and the student physical therapist showed very poor to high reliability (ICC = 0.07-0.85). Inter-rater reliability was highest during mid-stance at the knee with markers (ICC = 0.86) and lowest during mid-stance at the hip without markers (ICC = 0.25). Reliability of a single camera system, especially at the knee joint shows promise. Depending on the specific type of reliability, error can be attributed to the testers (e.g. lack of digitization practice and marker placement), participants (e.g. loose fitting clothing) and camera systems (e.g. frame rate and resolution). However, until the camera technology can be upgraded to a higher frame rate and resolution, and the software can be linked to the GAITRite walkway, the clinical utility for pre/post measures is limited.

  13. Ball-and-socket ankle joint

    International Nuclear Information System (INIS)

    Pistoia, F.; Ozonoff, M.B.; Wintz, P.; Hartford Hospital, CT

    1987-01-01

    The ball-and-socket ankle joint is a malformation of the ankle in which the articular surface of the talus is hemispherical in both the anteroposterior and lateral projections and has a congruent, concave tibial articular surface. Fourteen patients with this condition were identified retrospectively. Thirteen patients were thought to have the congenital type of ball-and-socket ankle joint which in many was associated with tarsal coalition, short limb, and ray fusion and deletion anomalies. One case of the acquired type, demonstrating less geometric rounding of the talar margins, was seen in a patient with myelomeningocele, probably resulting from sensory and motor deficits. Although the exact etiology of the congenital type is unknown, its association with other malformations suggests that the ball-and-socket ankle joint results from an overall maldevelopment of the ankle and foot. (orig.)

  14. Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.

    Science.gov (United States)

    Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao

    2015-11-01

    This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.

  15. Single-blind trial addressing the differential effects of two reflexology techniques versus rest, on ankle and foot oedema in late pregnancy.

    Science.gov (United States)

    Mollart, L

    2003-11-01

    This single-blind randomised controlled trial explored the differential effects of two different foot reflexology techniques with a period of rest on oedema-relieving effects and symptom relief in healthy pregnant women with foot oedema. Fifty-five women in the third trimester were randomly assigned to one of the three groups: a period of rest, 'relaxing' reflexology techniques or a specific 'lymphatic' reflexology technique for 15 min with pre- and post-therapy ankle and foot circumference measurements and participant questionnaire. There was no statistically significant difference in the circumference measurements between the three groups; however, the lymphatic technique reflexology group mean circumference measurements were all decreased. A significant reduction in the women's symptom mean measurements in all groups (preflexology techniques, relaxing reflexology techniques and a period of rest had a non-significant oedema-relieving effect. From the women's viewpoint, lymphatic reflexology was the preferred therapy with significant increase in symptom relief.

  16. Evidence of validity for the Japanese version of the foot and ankle ability measure.

    Science.gov (United States)

    Uematsu, Daisuke; Suzuki, Hidetomo; Sasaki, Shogo; Nagano, Yasuharu; Shinozuka, Nobuyuki; Sunagawa, Norihiko; Fukubayashi, Toru

    2015-01-01

    The Foot and Ankle Ability Measure (FAAM) is a valid, reliable, and self-reported outcome instrument for the foot and ankle region. To provide evidence for translation, cross-cultural adaptation, validity, and reliability of the Japanese version of the FAAM (FAAM-J). Cross-sectional study. Collegiate athletic training/sports medicine clinical setting. Eighty-three collegiate athletes. All participants completed the Activities of Daily Living and Sports subscales of the FAAM-J and the Physical Functioning and Mental Health subscales of the Japanese version of the Short Form-36v2 (SF-36). Also, 19 participants (23%) whose conditions were expected to be stable completed another FAAM-J 2 to 6 days later for test-retest reliability. We analyzed the scores of those subscales for convergent and divergent validity, internal consistency, and test-retest reliability. The Activities of Daily Living and Sports subscales of the FAAM-J had correlation coefficients of 0.86 and 0.75, respectively, with the Physical Functioning section of the SF-36 for convergent validity. For divergent validity, the correlation coefficients with Mental Health of the SF-36 were 0.29 and 0.27 for each subscale, respectively. Cronbach α for internal consistency was 0.99 for the Activities of Daily Living and 0.98 for the Sports subscale. A 95% confidence interval with a single measure was ±8.1 and ±14.0 points for each subscale. The test-retest reliability measures revealed intraclass correlation coefficient values of 0.87 for the Activities of Daily Living and 0.91 for the Sports subscales with minimal detectable changes of ±6.8 and ±13.7 for the respective subscales. The FAAM was successfully translated for a Japanese version, and the FAAM-J was adapted cross-culturally. Thus, the FAAM-J can be used as a self-reported outcome measure for Japanese-speaking individuals; however, the scores must be interpreted with caution, especially when applied to different populations and other types of

  17. Comparison of Suture-Based Anchors and Traditional Bioabsorbable Anchors in Foot and Ankle Surgery.

    Science.gov (United States)

    Hembree, W Chad; Tsai, Michael A; Parks, Brent G; Miller, Stuart D

    We compared the pullout strength of a suture-based anchor versus a bioabsorbable anchor in the distal fibula and calcaneus and evaluated the relationship between bone mineral density and peak load to failure. Eight paired cadaveric specimens underwent a modified Broström procedure and Achilles tendon reattachment. The fibula and calcaneus in the paired specimens received either a suture-based anchor or a bioabsorbable suture anchor. The fibular and calcaneal specimens were loaded to failure, defined as a substantial decrease in the applied load or pullout from the bone. In the fibula, the peak load to failure was significantly greater with the suture-based versus the bioabsorbable anchors (133.3 ± 41.8 N versus 76.8 ± 35.3 N; p = .002). No significant difference in load with 5 mm of displacement was found between the 2 groups. In the calcaneus, no difference in the peak load to failure was found between the 2 groups, and the peak load to failure with 5 mm of displacement was significantly lower with the suture-based than with the bioabsorbable anchors (52.2 ± 9.8 N versus 75.9 ± 12.4 N; p = .003). Bone mineral density and peak load to failure were significantly correlated in the fibula with the suture-based anchor. An innovative suture-based anchor had a greater peak load to failure compared with a bioabsorbable anchor in the fibula. In the calcaneus, the load at 5 mm of displacement was significantly lower in the suture-based than in the bioabsorbable group. The correlation findings might indicate the need for a cortical bone shelf with the suture-based anchor. Suture-based anchors could be a viable alternative to bioabsorbable anchors for certain foot and ankle procedures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. [Osseontegration of trial implants of carbon fiber reinforced plastics].

    Science.gov (United States)

    Schreiner, U; Schwarz, M; Scheller, G; Schroeder-Boersch, H; Jani, L

    2000-01-01

    To what extent are carbon fibre-reinforced plastics (CFRP) suitable as an osseous integration surface for implants? CFRP test implants having a plexus-structured, rhombus-structured, and plexus-structured, hydroxyapatite surface were implanted in the femura of mini-plgs. Exposure time lasted 12 weeks. The implants were subjected to a macroradiological, a histological-histomorphometrical, and a fluorescence-microscopical evaluation. One half of the uncoated, plexus-structured implants were not osteointegrated, the other half displayed an osteointegration rate of 11.8% in the spongy area and 29.8% in the cortex layer. The HA-coated test implants showed an osteointegration of 29.5% in the spongiosa and 56.8% in the cortex layer. The rhombus-structured test implants had an osteointegration of 29.2% (spongiosa) and 46.2% (cortex layer). Compared to the osteointegration of metallic, especially titanium surfaces the CFRP surfaces tested by us fared worse, especially the uncoated, plexus-structured surfaces. For this reason we view very critically the use of carbon-fibre reinforced plastics together with the surfaces tested by us as osteointegrating surfaces.

  19. Influence of fiber upon the radiation degradation of fiber-reinforced plastics

    International Nuclear Information System (INIS)

    Udagawa, Akira

    1992-01-01

    Influences of fiber upon the radiation degradation of fiber-reinforced plastics were investigated by using 2 MeV electrons. Radiation resistances were evaluated from the three-point bending strength of the fiber laminates which used bisphenol A-type epoxy resin as a matrix. Carbon fiber laminates had higher radiation resistance values than the laminates made of glass fiber. Model laminates using polyethylene as a matrix were prepared in order to examine the differences between carbon fiber and glass fiber filler, the relation between gel fraction and absorbed dose was established. When the polyethylene was filled in the carbon fiber, forming the gel was strikingly delayed. This result suggests that radiation protective action existing in carbon fiber to matrix resin is the main cause of the higher radiation resistance of carbon fiber reinforced plastics. (author)

  20. Study of the lateral raise in foot wear for the management of medial compartment degenerative joint disease of knee

    International Nuclear Information System (INIS)

    Ahmad, A.; Manawar, A.

    2014-01-01

    A wide spread disease, which may lead the patient to severe outcomes e.g. pain, loss of joint motion, inflexibility and even disability, is Knee osteoarthritis (OA). It is most common among adults of older age and should not be ignored at all. Literature does not show any clear pathogenesis for occurrence of Knee OA, but most of the indications point toward biomechanical stresses which may influence the articular cartilage and sub chondral bone. Objective: The Aim of this study is to become aware of the effects of physical therapy with and without laterally raised footwear in the management of medial knee osteoarthritis. Methodology: We have used experimental comparative study in 35 patients which were randomly selected from Department of Physiotherapy, Fatima Memorial Hospital, Shadman, Lahore. The study consisted of 2 groups, Group I (Experimental Group): In experimental group, patients were treated with laterally raised foot wear and physical therapy both. Group II (Control Group): Whereas in control group patients were treated by physical therapy alone. Kellgren and Lawrence (KL) scale was used to assess radiograph of the knee joints after an anteroposterior weight-bearing standing. The assessment of disease in patients was done by using the Western Ontario and McMaster Universities (WOMAC) Index, Muscle flexibility, Muscle strengthening and Tolerance scales. Results: In group-I the mean age of patients observed was 59.52+-13.66 years and 65+-12.87 years in Group-II. In Group-I, 9 (52.9%) patients were males and 8 (47.1%) patients were females while in Group-II, 9 patients (50%) were male and 9 (50%) were female. In Group-I 2 (11.8%) patients used flat and open shoes, 6 (35.3%) used flat and close shoe, 3 (17.6%) patients used dress shoes and 2 (11.8%) used flat shoes. In Group-I, the frequency of patients wearing laterally raised foot wear in terms of duration was; 5 (29.4%) patients for 20 days, 4 (23.5%) for 24 days, 4 (23.5%) for 25 days, whilst 2 patients

  1. Application of fibre reinforced plastic sandwich structures for automotive crashworthiness applications

    NARCIS (Netherlands)

    Lukaszewicz, D.; Blok, L.G.; Kratz, J.; Ward, C.; Kassapoglou, C.; Elmarakbi, A.; Araújo, A.L.

    2016-01-01

    In this work the application of fibre reinforced plastic (FRP) sandwich
    structures, with particular focus on aramid fibre tufted sandwiches is being studied for
    automotive crashworthiness applications using impact testing and numerical simulation.

  2. Assessment Impact of Foot Sensory Modulation on Inhibition of Hypertonicity of the Lower Limb in Children with Diplegia Spastic

    Directory of Open Access Journals (Sweden)

    Saeed Fatoureh-Chi

    2005-01-01

    Full Text Available Objective: The purpose of this study was to assess impact of foot sensory modulation on inhibition of hypertonicity of the lower limb in children with diplegia spastic cerebral palsy. Materials & Methods: 24 selected children (aged 2.5 to 4.5 years were randomly assigned to a control and experimental groups. Muscle tone was assessed using modified Ashworth scale, passive Range of motion by goniameter (Pedretti, neurodevelopmental level by Bobath scale. All children were pre-post tested in an interval of ten weeks. Results: Significant reduction was observed in hypertonicity of hip extensor (p<0/1 and ankle planter flexor (P<0/05. Significant increase was observed in passive Range of motion of hip flexion (P<0/1, knee extension (P<0/05 and ankle dorsi flexion (P<0/05. There was found no significant difference of reduction in hypertonicity of knee flexor and improvement neurodevelopmental level. Meaningful relationship was observed between reduction hypertonicity of the hip extensor (P<0/05 and improvement of neurodevelopmental level (P<0/05. Conclusion: Impact of sensory modulation on children with diplegia spastic cerebral palsy reduces spasticity of lower limb and also extends joints domain of motion.

  3. 脑性瘫痪患儿踝足矫形器配戴前后对运动功能的量化评价%Quantitative assessment of motor function on children with cerebral palsy before and after wearing ankle foot orthopedic instruments

    Institute of Scientific and Technical Information of China (English)

    李润洁

    2002-01-01

    Objective To assess motor function quantitatively on children with cerebral palsy before and after wearing ankle foot orthopedic instruments.Method Ankle foot orthopedic instruments were made by Dalian Prosthesis Factory.Children' motor function was assessed with self made quantitative assessment scale according to the forth,fifth function area of motor assessment scale of children with cerebral palsy after one week of wearing orthopedic instruments. Result In all 23 patients, orthopedic instruments proved effective in controlling leg muscular tension,correcting equines,genu recurvatum,talips valgus and talipes varus,keeping erect posture and modifying gait.Motor function assessed show significant difference before and one week after wearing orthopedic instruments (P< 0.001).Conclusion Ankle foot orthopedic instruments play a positive role in improving motor function of lower extremity in cerebral palsy patients.

  4. Warrior Transition Leader: Medical Rehabilitation Handbook

    Science.gov (United States)

    2011-01-01

    meter medley relay, swimming the anchor . After observing athletes with one leg competing in track during the 1996 Paralympics, Register was fitted with...down to the toes. Shoes, inserts, anklefoot orthotics, ankle braces, and knee braces are some of the devices commonly prescribed for various...conditions. Lower limb orthotics can be functional, accommodative, or corrective. The anklefoot orthosis fi g u r E 8-5. Wrist–hand orthosis. aSSiStivE

  5. Operative Fixation Options for Elective and Diabetic Ankle Arthrodesis.

    Science.gov (United States)

    Ramanujam, Crystal L; Stapleton, John J; Zgonis, Thomas

    2017-07-01

    Ankle arthrodesis remains one of the most definitive treatment options for end-stage arthritis, paralysis, posttraumatic and postinfectious conditions, failed total ankle arthroplasty, and severe deformities. The general aims of ankle arthrodesis are to decrease pain and instability, correct the accompanying deformity, and create a stable plantigrade foot. Several surgical approaches have been reported for ankle arthrodesis with internal fixation options. External fixation has also evolved for ankle arthrodesis in certain clinical scenarios. This article provides a comprehensive analysis of midterm to long-term outcomes for ankle arthrodesis using internal and/or external fixation each for elective and diabetic conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Normal foot and ankle

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The foot may be thought of as a bag of bones tied tightly together and functioning as a unit. The bones re expected to maintain their alignment without causing symptomatology to the patient. The author discusses a normal radiograph. The bones must have normal shape and normal alignment. The density of the soft tissues should be normal and there should be no fractures, tumors, or foreign bodies

  7. The Glasgow-Maastricht foot model, evaluation of a 26 segment kinematic model of the foot.

    Science.gov (United States)

    Oosterwaal, Michiel; Carbes, Sylvain; Telfer, Scott; Woodburn, James; Tørholm, Søren; Al-Munajjed, Amir A; van Rhijn, Lodewijk; Meijer, Kenneth

    2016-01-01

    Accurately measuring of intrinsic foot kinematics using skin mounted markers is difficult, limited in part by the physical dimensions of the foot. Existing kinematic foot models solve this problem by combining multiple bones into idealized rigid segments. This study presents a novel foot model that allows the motion of the 26 bones to be individually estimated via a combination of partial joint constraints and coupling the motion of separate joints using kinematic rhythms. Segmented CT data from one healthy subject was used to create a template Glasgow-Maastricht foot model (GM-model). Following this, the template was scaled to produce subject-specific models for five additional healthy participants using a surface scan of the foot and ankle. Forty-three skin mounted markers, mainly positioned around the foot and ankle, were used to capture the stance phase of the right foot of the six healthy participants during walking. The GM-model was then applied to calculate the intrinsic foot kinematics. Distinct motion patterns where found for all joints. The variability in outcome depended on the location of the joint, with reasonable results for sagittal plane motions and poor results for transverse plane motions. The results of the GM-model were comparable with existing literature, including bone pin studies, with respect to the range of motion, motion pattern and timing of the motion in the studied joints. This novel model is the most complete kinematic model to date. Further evaluation of the model is warranted.

  8. Gait Biomechanics in Participants, Six Months after First-time Lateral Ankle Sprain.

    Science.gov (United States)

    Doherty, C; Bleakley, C; Hertel, J; Caulfield, B; Ryan, J; Delahunt, E

    2016-06-01

    No research currently exists predicating a link between the injury-affiliated sensorimotor deficits of acute ankle sprain and those of chronic ankle instability during gait. This analysis evaluates participants with a 6-month history of ankle sprain injury to affirm this link. 69 participants with a 6-month history of acute first-time lateral ankle sprain were divided into subgroups ('chronic ankle instability' and 'coper') based on their self-reported disability and compared to 20 non-injured participants during a gait task. Lower extremity kinematic and kinetic data were collected from 200 ms pre- to 200 ms post-heel strike (period 1) and from 200 ms pre- to 200 ms post-toe off (period 2). The 'chronic ankle instability' subgroup (who reported greater disability) displayed increased knee flexion during period 1. During period 2, this subgroup exhibited greater total displacement at their ankle joint and greater extensor dominance at their knee. That many of these features are present, both in individuals with acute ankle sprain and those with chronic ankle instability may advocate a link between acute deficits and long-term outcome. Clinicians must be aware that the sensorimotor deficits of ankle sprain may persevere beyond the acute stage of injury and be cognizant of the capacity for impairments to pervade proximally. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Paratrooper's ankle fracture: posterior malleolar fracture.

    Science.gov (United States)

    Young, Ki Won; Kim, Jin-su; Cho, Jae Ho; Kim, Hyung Seuk; Cho, Hun Ki; Lee, Kyung Tai

    2015-03-01

    We assessed the frequency and types of ankle fractures that frequently occur during parachute landings of special operation unit personnel and analyzed the causes. Fifty-six members of the special force brigade of the military who had sustained ankle fractures during parachute landings between January 2005 and April 2010 were retrospectively analyzed. The injury sites and fracture sites were identified and the fracture types were categorized by the Lauge-Hansen and Weber classifications. Follow-up surveys were performed with respect to the American Orthopedic Foot and Ankle Society ankle-hindfoot score, patient satisfaction, and return to preinjury activity. The patients were all males with a mean age of 23.6 years. There were 28 right and 28 left ankle fractures. Twenty-two patients had simple fractures and 34 patients had comminuted fractures. The average number of injury and fractures sites per person was 2.07 (116 injuries including a syndesmosis injury and a deltoid injury) and 1.75 (98 fracture sites), respectively. Twenty-three cases (41.07%) were accompanied by posterior malleolar fractures. Fifty-five patients underwent surgery; of these, 30 had plate internal fixations. Weber type A, B, and C fractures were found in 4, 38, and 14 cases, respectively. Based on the Lauge-Hansen classification, supination-external rotation injuries were found in 20 cases, supination-adduction injuries in 22 cases, pronation-external rotation injuries in 11 cases, tibiofibular fractures in 2 cases, and simple medial malleolar fractures in 2 cases. The mean follow-up period was 23.8 months, and the average follow-up American Orthopedic Foot and Ankle Society ankle-hindfoot score was 85.42. Forty-five patients (80.36%) reported excellent or good satisfaction with the outcome. Posterior malleolar fractures occurred in 41.07% of ankle fractures sustained in parachute landings. Because most of the ankle fractures in parachute injuries were compound fractures, most cases had to

  10. Altered neuromuscular control and ankle joint kinematics during walking in subjects with functional instability of the ankle joint.

    Science.gov (United States)

    Delahunt, Eamonn; Monaghan, Kenneth; Caulfield, Brian

    2006-12-01

    The ankle joint requires very precise neuromuscular control during the transition from terminal swing to the early stance phase of the gait cycle. Altered ankle joint arthrokinematics and muscular activity have been cited as potential factors that may lead to an inversion sprain during the aforementioned time periods. However, to date, no study has investigated patterns of muscle activity and 3D joint kinematics simultaneously in a group of subjects with functional instability compared with a noninjured control group during these phases of the gait cycle. To compare the patterns of lower limb 3D joint kinematics and electromyographic activity during treadmill walking in a group of subjects with functional instability with those observed in a control group. Controlled laboratory study. Three-dimensional angular velocities and displacements of the hip, knee, and ankle joints, as well as surface electromyography of the rectus femoris, peroneus longus, tibialis anterior, and soleus muscles, were recorded simultaneously while subjects walked on a treadmill at a velocity of 4 km/h. Before heel strike, subjects with functional instability exhibited a decrease in vertical foot-floor clearance (12.62 vs 22.84 mm; P joint before, at, and immediately after heel strike (1.69 degrees , 2.10 degrees , and -0.09 degrees vs -1.43 degrees , -1.43 degrees , and -2.78 degrees , respectively [minus value = eversion]; P < .05) compared with controls. Subjects with functional instability were also observed to have an increase in peroneus longus integral electromyography during the post-heel strike time period (107.91%.millisecond vs 64.53%.millisecond; P < .01). The altered kinematics observed in this study could explain the reason subjects with functional instability experience repeated episodes of ankle inversion injury in situations with only slight or no external provocation. It is hypothesized that the observed increase in peroneus longus activity may be the result of a change in

  11. Gastrocnemius Recession Leads to Increased Ankle Motion and Improved Patient Satisfaction After 2 Years of Follow-Up

    DEFF Research Database (Denmark)

    Holtmann, Julia Alessandra; Südkamp, Norbert P; Schmal, Hagen

    2017-01-01

    The isolated gastrocnemius contracture present in neurologic healthy patients results in a significant limitation of ankle dorsiflexion causing pathologic gait patterns and a greater risk of further foot disorders. Gastrocnemius recession is an established procedure to increase ankle dorsiflexion....... However, little evidence is available of the use of gastrocnemius recession in these patients. Complication rates, recurrence of gastrocnemius contracture, and the prevalence of additional foot disorders needs further evaluation. A study group of 64 operated limbs undergoing gastrocnemius recession...... was evaluated to determine the prevalence of foot disorders, pre- and postoperative ankle dorsiflexion, and incidence of complications. A subgroup of 15 (23.4%) patients without additional operative procedures was examined regarding ankle dorsiflexion, strength (Janda method), sensitivity in the operated limb...

  12. Recycling of Reinforced Plastics

    Science.gov (United States)

    Adams, R. D.; Collins, Andrew; Cooper, Duncan; Wingfield-Digby, Mark; Watts-Farmer, Archibald; Laurence, Anna; Patel, Kayur; Stevens, Mark; Watkins, Rhodri

    2014-02-01

    This work has shown is that it is possible to recycle continuous and short fibre reinforced thermosetting resins while keeping almost the whole of the original material, both fibres and matrix, within the recyclate. By splitting, crushing hot or cold, and hot forming, it is possible to create a recyclable material, which we designate a Remat, which can then be used to remanufacture other shapes, examples of plates and tubes being demonstrated. Not only can remanufacturing be done, but it has been shown that over 50 % of the original mechanical properties, such as the E modulus, tensile strength, and interlaminar shear strength, can be retained. Four different forms of composite were investigated, a random mat Glass Fibre Reinforced Plastic (GFRP) bathroom component and boat hull, woven glass and carbon fibre cloth impregnated with an epoxy resin, and unidirectional carbon fibre pre-preg. One of the main factors found to affect composite recyclability was the type of resin matrix used in the composite. Thermoset resins tested were shown to have a temperature range around the Glass Transition Temperature (Tg) where they exhibit ductile behaviour, hence aiding reforming of the material. The high-grade carbon fibre prepreg was found to be less easy to recycle than the woven of random fibre laminates. One method of remanufacturing was by heating the Remat to above its glass transition temperature, bending it to shape, and then cooling it. However, unless precautions are taken, the geometric form may revert. This does not happen with the crushed material.

  13. A real-time computational model for estimating kinematics of ankle ligaments.

    Science.gov (United States)

    Zhang, Mingming; Davies, T Claire; Zhang, Yanxin; Xie, Sheng Quan

    2016-01-01

    An accurate assessment of ankle ligament kinematics is crucial in understanding the injury mechanisms and can help to improve the treatment of an injured ankle, especially when used in conjunction with robot-assisted therapy. A number of computational models have been developed and validated for assessing the kinematics of ankle ligaments. However, few of them can do real-time assessment to allow for an input into robotic rehabilitation programs. An ankle computational model was proposed and validated to quantify the kinematics of ankle ligaments as the foot moves in real-time. This model consists of three bone segments with three rotational degrees of freedom (DOFs) and 12 ankle ligaments. This model uses inputs for three position variables that can be measured from sensors in many ankle robotic devices that detect postures within the foot-ankle environment and outputs the kinematics of ankle ligaments. Validation of this model in terms of ligament length and strain was conducted by comparing it with published data on cadaver anatomy and magnetic resonance imaging. The model based on ligament lengths and strains is in concurrence with those from the published studies but is sensitive to ligament attachment positions. This ankle computational model has the potential to be used in robot-assisted therapy for real-time assessment of ligament kinematics. The results provide information regarding the quantification of kinematics associated with ankle ligaments related to the disability level and can be used for optimizing the robotic training trajectory.

  14. Machinability Study on Milling Kenaf Fiber Reinforced Plastic Composite Materials using Design of Experiments

    Science.gov (United States)

    Azmi, H.; Haron, C. H. C.; Ghani, J. A.; Suhaily, M.; Yuzairi, A. R.

    2018-04-01

    The surface roughness (Ra) and delamination factor (Fd) of a milled kenaf reinforced plastic composite materials are depending on the milling parameters (spindle speed, feed rate and depth of cut). Therefore, a study was carried out to investigate the relationship between the milling parameters and their effects on a kenaf reinforced plastic composite materials. The composite panels were fabricated using vacuum assisted resin transfer moulding (VARTM) method. A full factorial design of experiments was use as an initial step to screen the significance of the parameters on the defects using Analysis of Variance (ANOVA). If the curvature of the collected data shows significant, Response Surface Methodology (RSM) is then applied for obtaining a quadratic modelling equation that has more reliable in expressing the optimization. Thus, the objective of this research is obtaining an optimum setting of milling parameters and modelling equations to minimize the surface roughness (Ra) and delamination factor (Fd) of milled kenaf reinforced plastic composite materials. The spindle speed and feed rate contributed the most in affecting the surface roughness and the delamination factor of the kenaf composite materials.

  15. Nils Silfverskiöld (1888-1957) and gastrocnemius contracture.

    Science.gov (United States)

    Singh, Dishan

    2013-06-01

    Nils Silfverskiöld was an orthopaedic surgeon, Swedish aristocrat, bon vivant, Olympic gymnast, left wing intellectual and anti-Nazi who described that the force required to dorsiflex the ankle in spastic equinus contracture decreased with knee flexion in isolated gastrocnemius contracture. He advocated detaching the origins of the gastrocnemii from the femur and reattaching them to the tibia. The Silfverskiöld knee flexion test has now also been adapted to distinguish between isolated gastrocnemius contracture and combined shortening of the gastrocnemius-soleus complex in non-spastic contracture by measuring the range of ankle dorsiflexion with the knee flexed and the knee straight. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  16. Novel computational approaches characterizing knee physiotherapy

    Directory of Open Access Journals (Sweden)

    Wangdo Kim

    2014-01-01

    Full Text Available A knee joint’s longevity depends on the proper integration of structural components in an axial alignment. If just one of the components is abnormally off-axis, the biomechanical system fails, resulting in arthritis. The complexity of various failures in the knee joint has led orthopedic surgeons to select total knee replacement as a primary treatment. In many cases, this means sacrificing much of an otherwise normal joint. Here, we review novel computational approaches to describe knee physiotherapy by introducing a new dimension of foot loading to the knee axis alignment producing an improved functional status of the patient. New physiotherapeutic applications are then possible by aligning foot loading with the functional axis of the knee joint during the treatment of patients with osteoarthritis.

  17. Specific adaptations of neuromuscular control and knee joint stiffness following sensorimotor training.

    Science.gov (United States)

    Gruber, M; Bruhn, S; Gollhofer, A

    2006-08-01

    The aim of this study was to examine how fixations of the ankle joint during sensorimotor training (SMT) influence adaptations in mechanical stiffness and neuromuscular control of the knee joint. Sixty-three healthy subjects were randomly assigned to three training groups that differed in their degree of ankle joint fixation, which was either barefooted, with an ankle brace or with a ski boot. Mechanical knee joint stiffness and reflex control of m. vastus medialis, m. vastus lateralis, m. biceps femoris, and m. semitendinosus were tested during force controlled anterior tibial displacements. This force was applied as both a fast and a slow stimulus. After the training period the group that trained barefooted showed an increase in mechanical stiffness of the knee joint from 79 +/- 21 (Mean +/- SD) N/mm to 110 +/- 38 N/mm (p boots was able to improve knee joint stiffness from 67 +/- 26 N/mm to 96 +/- 47 N/mm (p knee joint injuries.

  18. A 3D musculoskeletal model of the western lowland gorilla hind limb: moment arms and torque of the hip, knee and ankle

    OpenAIRE

    Goh, Colleen; Blanchard, Mary L.; Crompton, Robin H.; Gunther, Michael M.; Macaulay, Sophie; Bates, Karl T.

    2017-01-01

    Abstract Three?dimensional musculoskeletal models have become increasingly common for investigating muscle moment arms in studies of vertebrate locomotion. In this study we present the first musculoskeletal model of a western lowland gorilla hind limb. Moment arms of individual muscles around the hip, knee and ankle were compared with previously published data derived from the experimental tendon travel method. Considerable differences were found which we attribute to the different methodolog...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  20. Comparison of Knee and Ankle Dynamometry between NASA's X1 Exoskeleton and Biodex System 4

    Science.gov (United States)

    English, K. L.; Newby, N. J.; Hackney, K. J.; DeWitt, J. K.; Beck, C. E.; Rovekamp, R. N.; Rea, R. L.; Ploutz-Snyder, L. L.

    2014-01-01

    Pre- and post-flight dynamometry is performed on International Space Station crewmembers to characterize microgravity-induced strength changes. Strength is not assessed in flight due to hardware limitations and there is poor understanding of the time course of in-flight changes. PURPOSE: To assess the reliability of a prototype dynamometer, the X1 Exoskeleton (EXO) and its agreement with a Biodex System 4 (BIO). METHODS: Eight subjects (4 M/4 F) completed 2 counterbalanced testing sessions of knee extension/flexion (KE/KF), 1 with BIO and 1 with EXO, with repeated measures within each session in normal gravity. Test-retest reliability (test 1 and 2) and device agreement (BIO vs. EXO) were evaluated. Later, to assess device agreement for ankle plantarflexion (PF), 10 subjects (4 M/6 F) completed 3 test conditions (BIO, EXO, and BIOEXO); BIOEXO was a hybrid condition comprised of the Biodex dynamometer motor and the X1 footplate and ankle frame. Ankle comparisons were: BIO vs. BIOEXO (footplate differences), BIOEXO vs. EXO (motor differences), and BIO vs. EXO (all differences). Reliability for KE/KF was determined by intraclass correlation (ICC). Device agreement was assessed with: 1) repeated measures ANOVA, 2) a measure of concordance (rho), and 3) average difference. RESULTS: ICCs for KE/KF were 0.99 for BIO and 0.96 to 0.99 for EXO. Agreement was high for KE (concordance: 0.86 to 0.95; average differences: -7 to +9 Nm) and low to moderate for KF (concordance: 0.64 to 0.78; average differences: -4 to -29 Nm, Pexoskeleton to perform portable dynamometry for large muscle groups of the lower body.

  1. Processing of microencapsulated dyes for the visual inspection of fibre reinforced plastics

    Energy Technology Data Exchange (ETDEWEB)

    Hopmann, Ch., E-mail: kerschbaum@ikv.rwth-aachen.de; Kerschbaum, M., E-mail: kerschbaum@ikv.rwth-aachen.de; Küsters, K., E-mail: kerschbaum@ikv.rwth-aachen.de [Institute of Plastics Processing at RWTH Aachen University (IKV), Pontstrasse 49, 52064 Aachen (Germany)

    2014-05-15

    The evaluation of damages caused during processing, assembly or usage of fibre reinforced plastics is still a challenge. The use of inspection technology like ultrasonic scanning enables a detailed damage analysis but requires high investments and trained staff. Therefore, the visual inspection method is widely used. A drawback of this method is the difficult identification of barely visible damages, which can already be detrimental for the structural integrity. Therefore an approach is undertaken to integrate microencapsulated dyes into the laminates of fibre reinforced plastic parts to highlight damages on the surface. In case of a damage, the microcapsules rupture which leads to a release of the dye and a visible bruise on the part surface. To enable a wide application spectrum for this technology the microcapsules must be processable without rupturing with established manufacturing processes for fibre reinforced plastics. Therefore the incorporation of microcapsules in the filament winding, prepreg autoclave and resin transfer moulding (RTM) process is investigated. The results show that the use of a carrier medium is a feasible way to incorporate the microcapsules into the laminate for all investigated manufacturing processes. Impact testing of these laminates shows a bruise formation on the specimen surface which correlates with the impact energy level. This indicates a microcapsule survival during processing and shows the potential of this technology for damage detection and characterization.

  2. Processing of microencapsulated dyes for the visual inspection of fibre reinforced plastics

    International Nuclear Information System (INIS)

    Hopmann, Ch.; Kerschbaum, M.; Küsters, K.

    2014-01-01

    The evaluation of damages caused during processing, assembly or usage of fibre reinforced plastics is still a challenge. The use of inspection technology like ultrasonic scanning enables a detailed damage analysis but requires high investments and trained staff. Therefore, the visual inspection method is widely used. A drawback of this method is the difficult identification of barely visible damages, which can already be detrimental for the structural integrity. Therefore an approach is undertaken to integrate microencapsulated dyes into the laminates of fibre reinforced plastic parts to highlight damages on the surface. In case of a damage, the microcapsules rupture which leads to a release of the dye and a visible bruise on the part surface. To enable a wide application spectrum for this technology the microcapsules must be processable without rupturing with established manufacturing processes for fibre reinforced plastics. Therefore the incorporation of microcapsules in the filament winding, prepreg autoclave and resin transfer moulding (RTM) process is investigated. The results show that the use of a carrier medium is a feasible way to incorporate the microcapsules into the laminate for all investigated manufacturing processes. Impact testing of these laminates shows a bruise formation on the specimen surface which correlates with the impact energy level. This indicates a microcapsule survival during processing and shows the potential of this technology for damage detection and characterization

  3. Processing of microencapsulated dyes for the visual inspection of fibre reinforced plastics

    Science.gov (United States)

    Hopmann, Ch.; Kerschbaum, M.; Küsters, K.

    2014-05-01

    The evaluation of damages caused during processing, assembly or usage of fibre reinforced plastics is still a challenge. The use of inspection technology like ultrasonic scanning enables a detailed damage analysis but requires high investments and trained staff. Therefore, the visual inspection method is widely used. A drawback of this method is the difficult identification of barely visible damages, which can already be detrimental for the structural integrity. Therefore an approach is undertaken to integrate microencapsulated dyes into the laminates of fibre reinforced plastic parts to highlight damages on the surface. In case of a damage, the microcapsules rupture which leads to a release of the dye and a visible bruise on the part surface. To enable a wide application spectrum for this technology the microcapsules must be processable without rupturing with established manufacturing processes for fibre reinforced plastics. Therefore the incorporation of microcapsules in the filament winding, prepreg autoclave and resin transfer moulding (RTM) process is investigated. The results show that the use of a carrier medium is a feasible way to incorporate the microcapsules into the laminate for all investigated manufacturing processes. Impact testing of these laminates shows a bruise formation on the specimen surface which correlates with the impact energy level. This indicates a microcapsule survival during processing and shows the potential of this technology for damage detection and characterization.

  4. Effect of compression therapy on knee swelling and pain after total knee arthroplasty

    DEFF Research Database (Denmark)

    Munk, Stig; Jensen, Niels J. F.; Andersen, Ida Bøgh

    2013-01-01

    PURPOSE: Knee swelling after total knee arthroplasty may impair postoperative mobilisation and training, and as medical elastic compression stockings are well tolerated and effective to prevent oedema, haematoma and postoperative pain after venous surgery, we wanted to study whether this effect...... could be transferred to total knee arthroplasty surgery reducing postoperative swelling and pain and thereby facilitating mobilisation and improving patient-reported knee function. METHODS: In a randomised controlled study, 88 patients were randomised to use either a medical elastic compression stocking...... or no stocking from the first postoperative day and the following 4 weeks after total knee arthroplasty. Outcome measures were knee, calf and ankle swelling, knee flexion, pain and patient-reported knee function. RESULTS: Seventy per cent of the swelling had occurred before application of the stocking the day...

  5. Roentgenofunctional investigation of the ankle joint in a long-term period after crural bone fracture

    International Nuclear Information System (INIS)

    Ignat'ev, Yu.T.; Novikov, V.P.

    1989-01-01

    On the basis of the results of clinicoroentgenological and tensographic investigations of 119 patients after traumas of the crural bones and ankle joint (2-36 yrs. ago) the authors showed the importance of roentgenofunctional investigation of the ankle joint. A specially designed footing was proposed. Of 77 patients after intra-articular fractures of the ankle bones various disorders in articular proportions, undetectable on routine roengenography, were diagnosed in 29 by functional roentgenography. Articular changes on roentgenofunctional investigation were revealed in one patient only out of 42 patients with extra-articular fractures of the crural bones. Tensography showed disorders of foot biomechanics in all patients with subluxations in the ankle

  6. Modeling initial contact dynamics during ambulation with dynamic simulation.

    Science.gov (United States)

    Meyer, Andrew R; Wang, Mei; Smith, Peter A; Harris, Gerald F

    2007-04-01

    Ankle-foot orthoses are frequently used interventions to correct pathological gait. Their effects on the kinematics and kinetics of the proximal joints are of great interest when prescribing ankle-foot orthoses to specific patient groups. Mathematical Dynamic Model (MADYMO) is developed to simulate motor vehicle crash situations and analyze tissue injuries of the occupants based multibody dynamic theories. Joint kinetics output from an inverse model were perturbed and input to the forward model to examine the effects of changes in the internal sagittal ankle moment on knee and hip kinematics following heel strike. Increasing the internal ankle moment (augmentation, equivalent to gastroc-soleus contraction) produced less pronounced changes in kinematic results at the hip, knee and ankle than decreasing the moment (attenuation, equivalent to gastroc-soleus relaxation). Altering the internal ankle moment produced two distinctly different kinematic curve morphologies at the hip. Decreased internal ankle moments increased hip flexion, peaking at roughly 8% of the gait cycle. Increasing internal ankle moments decreased hip flexion to a lesser degree, and approached normal at the same point in the gait cycle. Increasing the internal ankle moment produced relatively small, well-behaved extension-biased kinematic results at the knee. Decreasing the internal ankle moment produced more substantial changes in knee kinematics towards flexion that increased with perturbation magnitude. Curve morphologies were similar to those at the hip. Immediately following heel strike, kinematic results at the ankle showed movement in the direction of the internal moment perturbation. Increased internal moments resulted in kinematic patterns that rapidly approach normal after initial differences. When the internal ankle moment was decreased, differences from normal were much greater and did not rapidly decrease. This study shows that MADYMO can be successfully applied to accomplish forward

  7. Modulations of Foot and Ankle Frontal Kinematics for Breaking and Propulsive Movement Characteristics during Side-Step Cutting with Varying Midsole Thicknesses

    Directory of Open Access Journals (Sweden)

    Yi-Jia Lin

    2018-01-01

    Full Text Available This study is aimed at determining the effects of midsole thickness on movement characteristic during side cutting movement. Fifteen athletes performed side-step cutting while wearing shoes with varying midsole thicknesses. Temporal-spatial and ground reaction force variables as well as foot and ankle frontal kinematics were used to describe breaking and propulsive movement characteristics and modulation strategies. Regardless of midsole thickness, temporal-spatial variables and breaking and propulsive force during side cutting were statistically unchanged. Significantly greater peaks of ankle inversion and plantarflexion with a thicker sole and greater midtarsal pronation with a thinner sole were observed. Current results demonstrated that hypotheses formed solely based on material testing were insufficient to understand the adaptations in human movement because of the redundancy of the neuromusculoskeletal system. Participants were able to maintain temporal-spatial performance during side cutting while wearing shoes with midsoles of varying thicknesses. Increased pronation for a thinner sole might help reduce the force of impact but might be associated with an increased risk of excessive stress on soft tissue. Increased peak of ankle inversion and plantarflexion for a thicker sole may be unfavorable for the stability of ankle joint. Information provided in human movement testing is crucial for understanding factors associated with movement characteristics and injury and should be considered in the future development of shoe design.

  8. Modulations of Foot and Ankle Frontal Kinematics for Breaking and Propulsive Movement Characteristics during Side-Step Cutting with Varying Midsole Thicknesses

    Science.gov (United States)

    Lin, Yi-Jia; Lee, Shih-Chi; Chang, Chao-Chin; Liu, Tsung-Han

    2018-01-01

    This study is aimed at determining the effects of midsole thickness on movement characteristic during side cutting movement. Fifteen athletes performed side-step cutting while wearing shoes with varying midsole thicknesses. Temporal-spatial and ground reaction force variables as well as foot and ankle frontal kinematics were used to describe breaking and propulsive movement characteristics and modulation strategies. Regardless of midsole thickness, temporal-spatial variables and breaking and propulsive force during side cutting were statistically unchanged. Significantly greater peaks of ankle inversion and plantarflexion with a thicker sole and greater midtarsal pronation with a thinner sole were observed. Current results demonstrated that hypotheses formed solely based on material testing were insufficient to understand the adaptations in human movement because of the redundancy of the neuromusculoskeletal system. Participants were able to maintain temporal-spatial performance during side cutting while wearing shoes with midsoles of varying thicknesses. Increased pronation for a thinner sole might help reduce the force of impact but might be associated with an increased risk of excessive stress on soft tissue. Increased peak of ankle inversion and plantarflexion for a thicker sole may be unfavorable for the stability of ankle joint. Information provided in human movement testing is crucial for understanding factors associated with movement characteristics and injury and should be considered in the future development of shoe design. PMID:29854000

  9. Investigating Knee Alignment and Foot Structure in Futsal Players with and without Hamstring Shortness

    Directory of Open Access Journals (Sweden)

    Homan Minoonejad

    2016-09-01

    Methods: In this descriptive - comparative study, 30 men athlete (18- 25 years were recruited. They were assigned into two groups of 15 subjects with and without hamstring shortness. The hamstring shortness, knee and foot alignment were respectively measured by the goniometer, the ruler and caliper. After checking the normality of the data, (with Shapiro-Wilk test independent samples t-test, were used to analyze of data at a significance level of P 0.05. Conclusion: It seems that, navicular drop is not common among athletes with hamstring shortness.

  10. Possibilities of combined surgical treatment of pyonecrotic lesions in the neuroischemic form of diabetic foot syndrome

    Directory of Open Access Journals (Sweden)

    Valeriy Afanas'evich Mitish

    2009-03-01

    Full Text Available Aim. To present results of combined surgical treatment of the ischemic form of diabetic foot syndrome complicated by pyonecrotic process. To show thatthe use of modern diagnostic tools and the choice of adequate treatment strategy permits to substantially reduce the number of above-the-knee amputations. Materials and methods. A total of 140 patients with diabetes mellitus and critical ischemia of lower extremities were under observation during 2004-2008.All of them had purulent and/or necrotic foot lesions. The patients were examined by X-ray, computed and magneto-resonance tomography of the feet,duplex scanning of lower leg vasculature, transcutaneous measurement of PO2, pelvic and lower leg arterial angiography. Results. A strategy of surgical treatment was developed to be used depending on the patients health status, clinical features and severity of pyonecroticprocesses in the foot, and the degree of involvement of the main blood vessels of lower extremities. Conclusion. Combination of endovascular surgery with various methods for plastic wound closure permits to extend the range of possibilities for the treatmentof high-risk patients, such as those with pyonecrotic lesions and neuroischemic form of diabetic foot syndrome. This approach opens up prospects fora significant decrease of percentage of above-the-knee amputations and improves the quality of life in these patients.

  11. Is transcutaneous peroneal stimulation beneficial to patients with chronic stroke using an ankle-foot orthosis? A within-subjects study of patients' satisfaction, walking speed and physical activity level.

    NARCIS (Netherlands)

    Swigchem, R. van; Vloothuis, J.; Boer, J. de; Weerdesteijn, V.G.M.; Geurts, A.C.H.

    2010-01-01

    OBJECTIVE: The aim of this study was to evaluate whether community-dwelling chronic stroke patients wearing an ankle-foot orthosis would benefit from changing to functional electrical stimulation of the peroneal nerve. METHODS: In 26 community-dwelling chronic (> 6 months post-onset) patients after

  12. A large extraskeletal osteochondroma of the foot.

    Science.gov (United States)

    Estil, Jose Carlos C; Yeo, Eui-Dong; Kim, Hak Jun; Cho, Won Tae; Lee, Jeong-Ju

    2013-01-01

    Osteochondromas are very common benign tumors composed of cartilage and bone. They are usually found at the end of the growth plate of long bones, most often at the area of the joints, and are contiguous with the medullary cavity. Extraskeletal osteochondromas, the same as their namesake, are composed of cartilage and bone. However, unlike typical osteochondromas, extraskeletal osteochondromas are not contiguous with bone, as their name implies. They usually arise from the synovial tissue and tendon sheaths. Although rare, extraskeletal osteochondromas have been reported to occur within the knee and around the hip; however, they are more commonly reported to occur in the hands and feet. When found in the hands or feet, these new growths are often very small and only occasionally symptomatic. We present the case of a 49-year-old female who had a slow-growing mass of 4 years' duration, located on the plantar aspect of her left foot. The mass was slowly becoming more palpable as it increased in size and was progressively causing pain and discomfort during ambulation. Imaging studies revealed an ossified mass bearing no connection to any other structure on the plantar aspect of her foot. An excision biopsy was performed, and the easily dissectible mass, although much larger than its usual presentation, proved to be an extraskeletal osteochondroma. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Ambulatory Function and Perception of Confidence in Persons with Stroke with a Custom-Made Hinged versus a Standard Ankle Foot Orthosis

    Directory of Open Access Journals (Sweden)

    Angélique Slijper

    2012-01-01

    Full Text Available Objective. The aim was to compare walking with an individually designed dynamic hinged ankle foot orthosis (DAFO and a standard carbon composite ankle foot orthosis (C-AFO. Methods. Twelve participants, mean age 56 years (range 26–72, with hemiparesis due to stroke were included in the study. During the six-minute walk test (6MW, walking velocity, the Physiological Cost Index (PCI, and the degree of experienced exertion were measured with a DAFO and C-AFO, respectively, followed by a Stairs Test velocity and perceived confidence was rated. Results. The mean differences in favor for the DAFO were in 6MW 24.3 m (95% confidence interval [CI] 4.90, 43.76, PCI −0.09 beats/m (95% CI −0.27, 0.95, velocity 0.04 m/s (95% CI −0.01, 0.097, and in the Stairs Test −11.8 s (95% CI −19.05, −4.48. All participants except one perceived the degree of experienced exertion lower and felt more confident when walking with the DAFO. Conclusions. Wearing a DAFO resulted in longer walking distance and faster stair climbing compared to walking with a C-AFO. Eleven of twelve participants felt more confident with the DAFO, which may be more important than speed and distance and the most important reason for prescribing an AFO.

  14. Adding Stiffness to the Foot Modulates Soleus Force-Velocity Behaviour during Human Walking

    Science.gov (United States)

    Takahashi, Kota Z.; Gross, Michael T.; van Werkhoven, Herman; Piazza, Stephen J.; Sawicki, Gregory S.

    2016-07-01

    Previous studies of human locomotion indicate that foot and ankle structures can interact in complex ways. The structure of the foot defines the input and output lever arms that influences the force-generating capacity of the ankle plantar flexors during push-off. At the same time, deformation of the foot may dissipate some of the mechanical energy generated by the plantar flexors during push-off. We investigated this foot-ankle interplay during walking by adding stiffness to the foot through shoes and insoles, and characterized the resulting changes in in vivo soleus muscle-tendon mechanics using ultrasonography. Added stiffness decreased energy dissipation at the foot (p < 0.001) and increased the gear ratio (i.e., ratio of ground reaction force and plantar flexor muscle lever arms) (p < 0.001). Added foot stiffness also altered soleus muscle behaviour, leading to greater peak force (p < 0.001) and reduced fascicle shortening speed (p < 0.001). Despite this shift in force-velocity behaviour, the whole-body metabolic cost during walking increased with added foot stiffness (p < 0.001). This increased metabolic cost is likely due to the added force demand on the plantar flexors, as walking on a more rigid foot/shoe surface compromises the plantar flexors’ mechanical advantage.

  15. Characterizing multisegment foot kinematics during gait in diabetic foot patients

    Directory of Open Access Journals (Sweden)

    Denti Paolo

    2009-10-01

    Full Text Available Abstract Background The prevalence of diabetes mellitus has reached epidemic proportions, this condition may result in multiple and chronic invalidating long term complications. Among these, the diabetic foot, is determined by the simultaneous presence of both peripheral neuropathy and vasculopathy that alter the biomechanics of the foot with the formation of callosity and ulcerations. To diagnose and treat the diabetic foot is crucial to understand the foot complex kinematics. Most of gait analysis protocols represent the entire foot as a rigid body connected to the shank. Nevertheless the existing multisegment models cannot completely decipher the impairments associated with the diabetic foot. Methods A four segment foot and ankle model for assessing the kinematics of the diabetic foot was developed. Ten normal subjects and 10 diabetics gait patterns were collected and major sources of variability were tested. Repeatability analysis was performed both on a normal and on a diabetic subject. Direct skin marker placement was chosen in correspondence of 13 anatomical landmarks and an optoelectronic system was used to collect the data. Results Joint rotation normative bands (mean plus/minus one standard deviation were generated using the data of the control group. Three representative strides per subject were selected. The repeatability analysis on normal and pathological subjects results have been compared with literature and found comparable. Normal and pathological gait have been compared and showed major statistically significant differences in the forefoot and midfoot dorsi-plantarflexion. Conclusion Even though various biomechanical models have been developed so far to study the properties and behaviour of the foot, the present study focuses on developing a methodology for the functional assessment of the foot-ankle complex and for the definition of a functional model of the diabetic neuropathic foot. It is, of course, important to evaluate

  16. Correlation between anatomic foot and ankle movement measured with MRI and with a motion analysis system.

    Science.gov (United States)

    Marquez-Barrientos, C; Liu, X C; Lyon, R; Tassone, C; Thometz, J; Tarima, S

    2012-07-01

    Several studies have attempted to measure how well external markers track internal bone movement using pins drilled into the foot, but this is too invasive for the pediatric population. This study investigated how well a six segment foot model (6SFM) using external markers was able to measure bone movement in the foot compared to MRI measurements. The foot was moved into different positions using a plastic foot jig and measurements were taken with both systems. The aims were to: (1) Look at the correlation between movement tracked with an Electronic Motion Tracking System (EMTS) and by measurements derived from MRI images, specifically the principal intercept angles (PIAs) which are the angles of intersection between principal axes of inertia of bone volumes. (2) To see how well external motion measured by the 6SFM could predict PIAs. Four bone pairs had their movement tracked: Tibia-Calcaneus, Calcaneus-Cuboid, Navicular-1st Metatarsal, and 1st Metatarsal-Hallux. The results showed moderate correlation between measured PIAs and those predicted at the Tibia-Calcaneus, Navicular-1st Metatarsal, and 1st Metatarsal-Hallux joints. Moderate to high correlation was found between the PIA and movement in a single anatomic plane for all four joints at several positions. The 6SFM using the EMTS allows reliable tracking of 3D rotations in the pediatric foot, except at the Calcaneus-Cuboid joint. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Foot Kinetics and Kinematics Profile in Type 2 Diabetes Mellitus with Peripheral Neuropathy: A Hospital Based Study from South India.

    Science.gov (United States)

    Hazari, Animesh; Maiya, Arun G; N, Shivashankara K

    2018-02-01

    A kinetic change in thefoot like altered plantar pressure is the most common etiological risk factor for causing foot ulcers among people with diabetes mellitus. Kinematic alterations in joint angle and spatiotemporal parameters of the gait have also been frequently observed in participants with diabetes peripheral neuropathy. Diabetes peripheral neuropathy is the most common long-term standing complication of type 2 diabetes mellitus. It leads to various micro and macrovascular related complication of the foot. There is a gap in theliteraturefor biomechanical evaluation and assessment in type 2 diabetes mellitus with peripheral neuropathy in Indian population. The aim of the study was to assess and determine the biomechanical changes including kinetics and kinematics of foot among diabetic peripheral neuropathy. The cross-sectional study was conducted at Diabetic Foot Clinic, Kasturba Hospital, Manipal University, Manipal, Karnataka, India. A total of 120 participants with type 2 diabetes mellitus and peripheral neuropathywere recruited under the purposive sampling method. Participants with any active ulceration or amputation were excluded from the study. The mean age, height, weight, body mass index, duration of diabetes was 57±14 year, 164±11cm, 61±18kg, 24± 3, 12±7 year respectively. There were significant changes in overall biomechanical profile along with clinical manifestations of diabetes peripheral neuropathy.The regression analysis showed statistical significance for dynamic maximum plantar pressure at forefoot with age, weight, height, duration of diabetes, body mass index, knee & ankle joint angle at toe-off phase of gait cycle,pinprick sensation and ankle reflex (R=.71,R =.55, F (12, 108)=521.9 kPa, p=.002) Conclusions: From the present study, we conclude that people with type 2 diabetes mellitus and peripheral neuropathy have significant changes in their foot kinetics and kinematicsparameters. Therefore, they could be at higher risk of foot

  18. MRI of injuries of the lateral ankle ligaments

    International Nuclear Information System (INIS)

    Breitenseher, Martin

    2011-01-01

    The most frequent sport injury of the ankle is located in the lateral ankle ligaments. The diagnosis of lateral collateral ankle ligament trauma is based on patient history, clinical examination, and stress radiography, allowing a fair diagnosis for the daily routine. For the direct visualization and precise diagnosis of the lateral ankle ligaments MRI provides the best answer. MRI is used with controlled positioning of the foot, correct angulation of sequenzes, and distinct analysis of MR findings. Sinus tarsi ligaments and ligaments of the distal syndesmosis should be included to the report. In selected patients MRI allows the best evaluation of the extent of the lateral ankle ligaments. MRI is the method of choice for combined osteochondral injuries and soft tissue lesions too. (orig.)

  19. Parents: Avoid Kids Foot Problems with the Right Shoes

    Science.gov (United States)

    ... Print | Share Avoid Kids Foot Problems with the Right Shoes Before you head to the store to ... College of Foot and Ankle Surgeons (ACFAS), All Rights Reserved. Privacy Statement | Disclaimer | Terms and Conditions | Site ...

  20. AN ANALYSIS OF THE MANUFACTURING POSSIBILITY OF SPECIAL ANKLE FOOT ORTHOSIS COMPONENTS BY OMPARISON BETWEEN THE REQUIRED PRECISION AND THE VAILABLE PRECISION ON A VERTICAL MACHINING CENTER PROGRAMED WITH TOPSOLID

    Directory of Open Access Journals (Sweden)

    Alexandru STANIMIR

    2010-06-01

    Full Text Available Validation of different solutions adopted to achieve new ankle foot orthosis involves among others their prototyping. In these paper we developed a representative part for two axis machining that requires the use of the main features of TopSolid Cad and Cam modules, and that assumes the use of the main manufacturing processes that usually may be met on a vertical machining center. Also, in order to determine the dimensional and geometrical deviations of the part this was done on the YMC 1050 machining center. After comparing the measured deviations with the requirements of various components of orthesis, we concluded that the available precision meets the requirements and that the machining center with TopSolid software that we have will enable us to realize special ankle foot orthosis of quality, for experimental research .

  1. Speed-related spinal excitation from ankle dorsiflexors to knee extensors during human walking

    DEFF Research Database (Denmark)

    Iglesias, Caroline; Nielsen, Jens Bo; Marchand-Pauvert, Véronique

    2008-01-01

    Automatic adjustments of muscle activity throughout the body are required for the maintenance of balance during human walking. One mechanism that is likely to contribute to this control is the heteronymous spinal excitation between human ankle dorsiflexors and knee extensors (CPQ-reflex). Here, we...... investigated the CPQ-reflex at different walking speeds (1-6 km/h) and stride frequencies (0.6-1.3 Hz) in healthy human subjects to provide further evidence of its modulation, and its role in ensuring postural stability during walking. The CPQ-reflex was small or absent at walking speeds below 2-3 km....../h, then increased with walking speeds about 3-4 km/h, and reached a plateau without any further change at walking speeds from 4 to 6 km/h. The reflex showed no modulation when the stride cycle was varied at constant speed (4 km/h; short steps versus long steps). These changes were unlikely to be only caused...

  2. Finite element modeling of a 3D coupled foot-boot model.

    Science.gov (United States)

    Qiu, Tian-Xia; Teo, Ee-Chon; Yan, Ya-Bo; Lei, Wei

    2011-12-01

    Increasingly, musculoskeletal models of the human body are used as powerful tools to study biological structures. The lower limb, and in particular the foot, is of interest because it is the primary physical interaction between the body and the environment during locomotion. The goal of this paper is to adopt the finite element (FE) modeling and analysis approaches to create a state-of-the-art 3D coupled foot-boot model for future studies on biomechanical investigation of stress injury mechanism, foot wear design and parachute landing fall simulation. In the modeling process, the foot-ankle model with lower leg was developed based on Computed Tomography (CT) images using ScanIP, Surfacer and ANSYS. Then, the boot was represented by assembling the FE models of upper, insole, midsole and outsole built based on the FE model of the foot-ankle, and finally the coupled foot-boot model was generated by putting together the models of the lower limb and boot. In this study, the FE model of foot and ankle was validated during balance standing. There was a good agreement in the overall patterns of predicted and measured plantar pressure distribution published in literature. The coupled foot-boot model will be fully validated in the subsequent works under both static and dynamic loading conditions for further studies on injuries investigation in military and sports, foot wear design and characteristics of parachute landing impact in military. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Protocol for the Foot in Juvenile Idiopathic Arthritis trial (FiJIA: a randomised controlled trial of an integrated foot care programme for foot problems in JIA

    Directory of Open Access Journals (Sweden)

    Hendry Gordon J

    2009-06-01

    Full Text Available Abstract Background Foot and ankle problems are a common but relatively neglected manifestation of juvenile idiopathic arthritis. Studies of medical and non-medical interventions have shown that clinical outcome measures can be improved. However existing data has been drawn from small non-randomised clinical studies of single interventions that appear to under-represent the adult population suffering from juvenile idiopathic arthritis. To date, no evidence of combined therapies or integrated care for juvenile idiopathic arthritis patients with foot and ankle problems exists. Methods/design An exploratory phase II non-pharmacological randomised controlled trial where patients including young children, adolescents and adults with juvenile idiopathic arthritis and associated foot/ankle problems will be randomised to receive integrated podiatric care via a new foot care programme, or to receive standard podiatry care. Sixty patients (30 in each arm including children, adolescents and adults diagnosed with juvenile idiopathic arthritis who satisfy the inclusion and exclusion criteria will be recruited from 2 outpatient centres of paediatric and adult rheumatology respectively. Participants will be randomised by process of minimisation using the Minim software package. The primary outcome measure is the foot related impairment measured by the Juvenile Arthritis Disability Index questionnaire's impairment domain at 6 and 12 months, with secondary outcomes including disease activity score, foot deformity score, active/limited foot joint counts, spatio-temporal and plantar-pressure gait parameters, health related quality of life and semi-quantitative ultrasonography score for inflammatory foot lesions. The new foot care programme will comprise rapid assessment and investigation, targeted treatment, with detailed outcome assessment and follow-up at minimum intervals of 3 months. Data will be collected at baseline, 6 months and 12 months from baseline

  4. How can push-off be preserved during use of an ankle foot orthosis in children with hemiplegia? A prospective controlled study

    OpenAIRE

    Desloovere, Kaat; Molenaers, Guy; Van Gestel, Leen; Huenaerts, Catherine; Van Campenhout, Anja; Callewaert, Barbara; Van De Walle, Patricia; Seyler, J

    2006-01-01

    Several studies indicated that walking with an ankle foot orthosis (AFO) impaired third rocker. The purpose of this study was to evaluate the effects of two types of orthoses, with similar goal settings, on gait, in a homogeneous group of children, using both barefoot and shoe walking as control conditions. Fifteen children with hemiplegia, aged between 4 and 10 years, received two types of individually tuned AFOs: common posterior leaf-spring (PLS) and Dual Carbon Fiber Spring AFO (CFO) (wit...

  5. Transfibular ankle arthrodesis: A novel method for ankle fusion - A short term retrospective study

    Directory of Open Access Journals (Sweden)

    S Muthukumar Balaji

    2017-01-01

    Full Text Available Background: Ankle arthrodesis has long been the traditional operative treatment for posttraumatic arthritis, rheumatoid arthritis, infection, neuromuscular conditions, and salvage of failed ankle arthroplasty. It remains the treatment of choice for patients in whom heavy and prolonged activity is anticipated. We present our short term followup study of functional outcome of patients who underwent transfibular ankle arthrodesis for arthritis of ankle due to various indications. Materials and Methods: 29 transfibular ankle arthrodesis in 29 patients performed between April 2009 and April 2014 were included in this study. The mean age was 50 years (range 22-75 years. The outcome analysis with a minimum of 1-year postoperative followup were included. All the patients were assessed with the American Orthopaedic Foot and Ankle Society (AOFAS Hindfoot scale. Results: All cases of ankle fusions (100% progressed to solid union in a mean postoperative duration of 3.8 months (range 3-6 months. All patients had sound arthrodesis. The mean followup period was 32.52 months (standard deviation ± 10.34. The mean AOFAS score was 74 (pain score = 32, functional score = 42. We found that twenty patients (68.96% out of 29, had excellent results, 7 (24.13% had good, and 2 (6.89% showed fair results. Conclusion: Transfibular ankle arthrodesis is a simple and effective procedure for ankle arthritis. It achieves a high rate of union and good functional outcome on midterm followup.

  6. Nonlocal plasticity effects on fibre debonding in a whisker-reinforced metal

    DEFF Research Database (Denmark)

    Niordson, Christian Frithiof; Tvergaard, Viggo

    2002-01-01

    Numerical cell-model analyses for the matrix-fibre debonding in a metal matrix composite are used to study the effect of a characteristic material length in the plasticity description of the matrix material deformations. Characteristic material lengths are already present in the model problem...... in the problem. The nonlocal plasticity effect tends to increase the stress level at a given overall strain, which clearly tends to promote the onset of debonding......., in the form of fibre sizes and the length associated with the debonding process, so the nonlocal plasticity model brings in an additional material length. The analyses for metal reinforced by aligned short fibres are used to obtain an understanding of the interaction of the different length scales...

  7. Incidence, mass and variety of plastics ingested by Laysan (Phoebastria immutabilis) and Black-footed Albatrosses (P. nigripes) recovered as by-catch in the North Pacific Ocean.

    Science.gov (United States)

    Gray, Holly; Lattin, Gwendolyn L; Moore, Charles J

    2012-10-01

    Laysan Albatrosses (Phoebastria immutabilis) and Black-footed Albatrosses (P. nigripes) ingest plastic debris, as evidenced by studies showing plastic in the digestive contents of their chicks, but there is little documentation of the frequency and amount of ingested plastics carried in foraging adults. In this study, we quantify plastics among the digestive contents of 18 Laysan Albatrosses and 29 Black-footed Albatrosses collected as by-catch in the North Pacific Ocean. We found ingested plastic in 30 of the 47 birds examined, with Laysan Albatrosses exhibiting a greater frequency of plastic ingestion (83.3% n=18) than Black-footed Albatrosses (51.7% n=29) (X(2)=4.8, df=1, P=0.03). Though the mass of ingested plastic in both species (mean±SD=0.463g±1.447) was lower than previously noted among albatross chicks, the high frequency of ingested plastic we found in this study suggests that long-term effects, e.g. absorption of contaminants from plastics, may be of concern throughout the population. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Resistance Training With Ankle Weight Cuffs Is Feasible in Patients With Acute Exacerbation of COPD

    DEFF Research Database (Denmark)

    Kofod, Linette Marie; Døssing, Martin; Steentoft, Johnna

    2017-01-01

    -extension strength training. During training, the patients were seated on the bedside and performed 3 sets of 10-repetition maximum loads, using ankle weight cuffs. The primary outcome was the change in load from the first to last training sessions. The secondary outcomes were changes in maximal isometric knee......-extension strength improved by a mean of 12% (P = .02), whereas the TUG and STS test performances improved by 11% (P = .001) and 19% (P = .03), respectively. Ninety-eight percent of the planned training sessions were completed with no side effects. CONCLUSIONS: Progressive resistance training with ankle weight cuffs...... of progressive knee-extension resistance training, using ankle weight cuffs on patients with AECOPD, based on prespecified criteria for feasibility. METHODS: Thirty-four patients (18 men, mean age 74 years, forced expiratory volume in 1 second = 33% predicted) with AECOPD participated in daily knee...

  9. Diabetic Foot Complications Despite Successful Pancreas Transplantation.

    Science.gov (United States)

    Seo, Dong-Kyo; Lee, Ho Seong; Park, Jungu; Ryu, Chang Hyun; Han, Duck Jong; Seo, Sang Gyo

    2017-06-01

    It is known that successful pancreas transplantation enables patients with diabetes to maintain a normal glucose level without insulin and reduces diabetes-related complications. However, we have little information about the foot-specific morbidity in patients who have undergone successful pancreas transplantation. The purpose of this study was to investigate the prevalence and predisposing factors for foot complications after successful pancreas transplantation. This retrospective study included 218 patients (91 males, 127 females) who had undergone pancreas transplantation for diabetes. The mean age was 40.7 (range, 15-76) years. Diabetes type, transplantation type, body mass index, and diabetes duration before transplantation were confirmed. After pancreas transplantation, the occurrence and duration of foot and ankle complications were assessed. Twenty-two patients (10.1%) had diabetic foot complications. Fifteen patients (6.9%) had diabetic foot ulcer and 7 patients (3.2%) had Charcot arthropathy. Three patients had both diabetic foot ulcer and Charcot arthropathy. Three insufficiency fractures (1.4%) were included. Mean time of complications after transplantation was 18.5 (range, 2-77) months. Creatinine level 1 year after surgery was higher in the complication group rather than the noncomplication group ( P = .02). Complications of the foot and ankle still occurred following pancreas transplantation in patients with diabetes. Level III, comparative study.

  10. An Evaluation of the Correlation between the Free Moments Applied on the Lower Extremity and the Knee Extensor Mechanism Force in Pronated Foot Subjects during the Stance Phase of Gait

    Directory of Open Access Journals (Sweden)

    Farzaneh Yazdani

    2016-12-01

    Full Text Available Background: Due to the rotatory nature of the excessive subtalar pronation and the possible impairment of the tibial rotation-knee flexion mechanism, changes of the free moment (FM and changes of the extensor mechanism force are expected in hyper-pronated foot subjects. The purpose of this study was to evaluate the correlation between the FM applied on the lower extremity and the knee extensor mechanism force in subjects with flexible pronated feet. Methods: Fifteen asymptomatic female subjects (21.32±1.66 y, 56.30±6.08 kg, 159±6.3 cm participated in the study. Excessive subtalar pronation was determined by measuring the resting calcaneal stance position (RCSP in the frontal plane during weight bearing. A neutrally aligned foot was defined as having an RCSP between 2° of inversion and 2° of eversion. On the other hand, a flat foot had an RCSP of more than or equal to 4° of eversion. Both kinetic and kinematic data were collected using a six-camera motion analysis system and a single force plate. Three successful barefoot walking trials were recorded at selfselected speeds. The extensor mechanism force and the adductory component of the free moment (ADD FM were calculated. The correlation between the ADD FM and the knee extensor mechanism force was examined using the Pearson correlation test. Results: The Pearson correlation analysis showed a high positive correlation between the ADD FM and the extensor mechanism force (r=0.917, P<0.001. Conclusion: Excessive subtalar pronation, along with a possible impairment of the tibial rotation-knee flexion mechanism, may affect the extensor mechanism force at the knee joint. From a clinical perspective, the possible biomechanical linkage between the knee and the foot complex in the physical examination and treatment of patients should be considered.

  11. Imaging of orthopedic trauma and surgery

    International Nuclear Information System (INIS)

    Berquist, T.H.

    1985-01-01

    This book presents papers on imaging techniques for diagnosis of trauma of bones. A comparative evaluation is presented for planning of proper diagnosis and treatment. Various techniques discussed are routine radiography; computerized tomography, NMR imaging, angiography, ultrasonography; and use of radioisotopes. The mechanism of injury of bone joints of upper and lower limbs and spine is discussed after discussing the anatomy of each in the beginning of each paper. Topics titled are healing of fractures; fractures of pelvis; knee; shoulder; foot and ankle; fractures of humerus; stress fractures; and orthopedic radiology. Prosthesis use and plastic surgery of joints is also discussed

  12. Fiber breakage phenomena in long fiber reinforced plastic preparation

    International Nuclear Information System (INIS)

    Huang, Chao-Tsai; Tseng, Huan-Chang; Chang, Rong-Yeu; Vlcek, Jiri

    2015-01-01

    Due to the high demand of smart green, the lightweight technologies have become the driving force for the development of automotives and other industries in recent years. Among those technologies, using short and long fiber-reinforced plastics (FRP) to replace some metal components can reduce the weight of an automotive significantly. However, the microstructures of fibers inside plastic matrix are too complicated to manage and control during the injection molding through the screw, the runner, the gate, and then into the cavity. This study focuses on the fiber breakage phenomena during the screw plastification. Results show that fiber breakage is strongly dependent on screw design and operation. When the screw geometry changes, the fiber breakage could be larger even with lower compression ratio. (paper)

  13. Ankle and subtalar synovitis in a ball-and-socket ankle joint causing posterolateral painful coarse crepitus: a case report.

    Science.gov (United States)

    Fan, Ka Yuk; Lui, Tun Hing

    2014-01-01

    A 17-year-old girl with bilateral ball-and-socket ankles reported left medial heel pain. Her left heel had gone into a varus position on tiptoeing, and a painful clunk had occurred when returning to normal standing. The clunk persisted after physiotherapy and treatment with an orthosis. Subtalar arthroscopy and peroneal tendoscopy showed mild diffuse synovitis of the ankle joint, especially over the posterior capsule, and a patch of inflamed and fibrotic synovium at the posterolateral corner of the subtalar joint. The clunk subsided immediately after arthroscopic synovectomy and had not recurred during 5 years of follow-up. We found no other reported cases of ankle and subtalar synovitis occurring in patients with a ball-and-socket ankle joint. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    Science.gov (United States)

    Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej

    2015-01-01

    The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the

  15. Immediate effects of using ankle-foot orthoses in the kinematics of gait and in the balance reactions in Charcot-Marie-Tooth disease

    OpenAIRE

    Pereira, Rouse Barbosa; Felício, Lílian Ramiro; Ferreira, Arthur de Sá; Menezes, Sara Lúcia de; Freitas, Marcos Raimundo Gomes de; Orsini, Marco

    2014-01-01

    The Charcot-Marie-Tooth (CMT) disease is a peripheral hereditary neuropathy with progressive distal muscle atrophy and weakness, mainly in lower limbs, that evolves limiting the gait and balance. The objective of the study was to analyse the immediate effects of using Ankle-Foot Orthosis (AFO) in the gait's kinematics and balance in patients with CMT. Nine individuals were evaluated by Tinetti scales and Dynamic Gait Index (DGI) and gait's kinematics parameters through the motion capturing sy...

  16. Incidence and MR imaging features of fractures of the anterior process of calcaneus in a consecutive patient population with ankle and foot symptoms

    International Nuclear Information System (INIS)

    Ouellette, H.; Salamipour, H.; Thomas, B.J.; Kassarjian, A.; Torriani, M.

    2006-01-01

    To determine the incidence, appearances and associated injuries of fractures affecting the anterior process of calcaneus from a general population with foot and ankle symptoms. A retrospective review of foot and ankle MR imaging procedures was performed for detection of cases with a fracture affecting the anterior process of calcaneus over a four year period. Radiographs, MR imaging studies, radiology reports, medical records, and operative notes were reviewed. Imaging analysis included fracture pattern, displacement, associated fractures, and presence of tendon and ligamentous injuries. The incidence of anterior process of calcaneus fracture on MR imaging was 0.5% (14/2577). Fractures were more common in female subjects (71%, 10/14). Fracture orientation was predominantly vertical (93%, 13/14). No comminuted fractures were seen and only three fractures were displaced. Three of the eight MR imaging evident fractures of anterior process of calcaneus were seen on radiographs. Associated fractures of the talus (n=5), navicular bone (n=3), cuboid (n=2), and calcaneal body (n=1) were noted. Associated injuries to the anterior talofibular ligament (n=3) and tears of the peroneus brevis (n=3) and peroneus longus (n=1) tendons were present. All fractures were treated non-operatively. Two patients had subtalar joint steroid injection for symptomatic relief

  17. Incidence and MR imaging features of fractures of the anterior process of calcaneus in a consecutive patient population with ankle and foot symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Ouellette, H.; Salamipour, H.; Thomas, B.J.; Kassarjian, A.; Torriani, M. [Division of Musculoskeletal Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2006-11-15

    To determine the incidence, appearances and associated injuries of fractures affecting the anterior process of calcaneus from a general population with foot and ankle symptoms. A retrospective review of foot and ankle MR imaging procedures was performed for detection of cases with a fracture affecting the anterior process of calcaneus over a four year period. Radiographs, MR imaging studies, radiology reports, medical records, and operative notes were reviewed. Imaging analysis included fracture pattern, displacement, associated fractures, and presence of tendon and ligamentous injuries. The incidence of anterior process of calcaneus fracture on MR imaging was 0.5% (14/2577). Fractures were more common in female subjects (71%, 10/14). Fracture orientation was predominantly vertical (93%, 13/14). No comminuted fractures were seen and only three fractures were displaced. Three of the eight MR imaging evident fractures of anterior process of calcaneus were seen on radiographs. Associated fractures of the talus (n=5), navicular bone (n=3), cuboid (n=2), and calcaneal body (n=1) were noted. Associated injuries to the anterior talofibular ligament (n=3) and tears of the peroneus brevis (n=3) and peroneus longus (n=1) tendons were present. All fractures were treated non-operatively. Two patients had subtalar joint steroid injection for symptomatic relief.

  18. Operational factors influence on service life characteristics of structural carbon fiber-reinforced plastic

    OpenAIRE

    Борозенець, Григорій; Павлов, Віктор; Семак, Інна

    2013-01-01

    The nature of strength changing of aircraft structural carbon fiber-reinforced plastic under influence of water saturation after static preloading and mode changing of structural elements forming process pressure is considered.

  19. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    Energy Technology Data Exchange (ETDEWEB)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Espinosa, Norman [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland)

    2017-08-15

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)

  20. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    International Nuclear Information System (INIS)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja; Espinosa, Norman

    2017-01-01

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)