WorldWideScience

Sample records for reinforced concrete strengthening

  1. Shear Strengthening of Reinforced Concrete Beams Using GFRP Wraps

    Directory of Open Access Journals (Sweden)

    M. A. A. Saafan

    2006-01-01

    Full Text Available The objective of the experimental work described in this paper was to investigate the efficiency of GFRP composites in strengthening simply supported reinforced concrete beams designed with insufficient shear capacity. Using the hand lay-up technique, successive layers of a woven fiberglass fabric were bonded along the shear span to increase the shear capacity and to avoid catastrophic premature failure modes. The strengthened beams were fabricated with no web reinforcement to explore the efficiency of the proposed strengthening technique using the results of control beams with closed stirrups as a  web reinforcement. The test results of 18 beams are reported, addressing the influence of different shear strengthening schemes and variable longitudinal reinforcement ratios on the structural behavior. The results indicated that significant increases in the shear strength and improvements in the overall structural behavior of beams with insufficient shear capacity could be achieved by proper application of GFRP wraps.

  2. Acrylic Rubber Latex in Ferrocement for Strengthening Reinforced Concrete Beams

    Directory of Open Access Journals (Sweden)

    D. R. Kumar

    2010-01-01

    Full Text Available Problem statement: In India, the early deterioration of reinforced concrete structures has become a big social problem in recent years. An essential research is needed for the development of effective repair materials and their execution systems comes to an important issue from the viewpoint of the longevity of infrastructures at present. Ferrocement laminates are introduced to enhance the overall performance of Reinforced Concrete (RC structures and these days the use of it is a promising technology for increasing the flexural strength of deficient reinforced concrete members. Approach: The repair system aims to provide quantitative repair enhancement as well as extending the life of deteriorated concrete members. This research in particular inspired the initiation of the present work which aimed to develop a material with unique properties and a very wide range of practical applications. The mechanical properties of mortar through difference in polymer content with Acrilic Latex by ferrocement among three different volume fractions of mesh reinforcement were studied. Following the encouraging progress made in the formulation and evaluation of the polymer modified repair mortar, tests were carried out involving the application of the reinforced repair material to the soffit of the reinforced concrete beams of 3 m length. Results: The levels of damage of the original beams prior to repair did not affect the ultimate load of the strengthened beams tested. The performance of the strengthened beams was compared to the control beams with respect to cracking, deflection and ultimate strength which confirm preeminent results. Conclusion: This accomplished the fact that acrylic rubber latex modified ferrocement is a doable alternative strengthening component for the rehabilitation of reinforced concrete structures. Further developments in these systems will create dramatic improvement into the field of rehabilitation of old privileged structures.

  3. Engineered cementitious composites for strengthening masonry infilled reinforced concrete frames

    DEFF Research Database (Denmark)

    Dehghani, Ayoub; Nateghi-Alahi, Fariborz; Fischer, Gregor

    2015-01-01

    The results of the second part of a comprehensive experimental program, aimed at investigating the behavior of masonry infilled reinforced concrete (RC) frames strengthened with fiber reinforced engineered cementitious composites (ECC) used as an overlay on the masonry wall, are presented in this...... and energy absorption capacity of the infilled frame, prevent brittle failure modes in the infill wall, and provide a reasonable system overstrength....

  4. COMPOSITE STRENGTHENING SOLUTIONS FOR REINFORCED CONCRETE LOAD BEARING ELEMENTS

    Directory of Open Access Journals (Sweden)

    Nicolae ȚĂRANU

    2015-11-01

    Full Text Available The results of a complex research and development program relating to the use of fiber reinforced polymeric composite strengthening solutions carried out at the Faculty of Civil Engineering and Building Services Iasi, are presented in this paper. The program has included the conceiving of the structural rehabilitation systems, the detailing and experimental testing of some solutions applied to reinforced concrete beams, slabs and columns (with circular and square cross-section. An efficient use of the component materials to improve the structural performance of the studied reinforced concrete element has been the main target of the research program. The main benefits resulted from the research program refer to the increase of the load capacities, the improvement of the structural response of all strengthened elements and a better control of the failure modes.

  5. Experimental analysis of reinforced concrete beams strengthened in bending with carbon fiber reinforced polymer

    Directory of Open Access Journals (Sweden)

    M. M. VIEIRA

    Full Text Available The use of carbon fiber reinforced polymer (CFRP has been widely used for the reinforcement of concrete structures due to its practicality and versatility in application, low weight, high tensile strength and corrosion resistance. Some construction companies use CFRP in flexural strengthening of reinforced concrete beams, but without anchor systems. Therefore, the aim of this study is analyze, through an experimental program, the structural behavior of reinforced concrete beams flexural strengthened by CFRP without anchor fibers, varying steel reinforcement and the amount of carbon fibers reinforcement layers. Thus, two groups of reinforced concrete beams were produced with the same geometric feature but with different steel reinforcement. Each group had five beams: one that is not reinforced with CFRP (reference and other reinforced with two, three, four and five layers of carbon fibers. Beams were designed using a computational routine developed in MAPLE software and subsequently tested in 4-point points flexural test up to collapse. Experimental tests have confirmed the effectiveness of the reinforcement, ratifying that beams collapse at higher loads and lower deformation as the amount of fibers in the reinforcing layers increased. However, the increase in the number of layers did not provide a significant increase in the performance of strengthened beams, indicating that it was not possible to take full advantage of strengthening applied due to the occurrence of premature failure mode in the strengthened beams for pullout of the cover that could have been avoided through the use of a suitable anchoring system for CFRP.

  6. REPAIR AND STRENGTHENING OF REINFORCED CONCRETE BEAMS USING FIBRE REINFORCED POLIMER (FRP MATERIALS

    Directory of Open Access Journals (Sweden)

    Nihat ÇETİNKAYA

    2004-03-01

    Full Text Available The use of Fibre Reinforced Polimer (FRP materials for the repair and strengthening of Reinforced Concrete structures has become widespread recently. FRP materials are being prefered because they have very high tensile strength, resistance to corrosion and they do not affect the use of the building during the repair and strengthening process. Four reinfoced concrete beams repaired and strengthened with FRP materials have been used in this study which were performed at Pamukkale University-Faculty of Engineering- Civil Engineering Department- Structural Engineering Laboratuary. The behaviour of the beams before and after repair and strengthening was compared by obtaining the load- displacement curves under static loading. In this study, it was observed that the repair and strengthening of reinforced concrete beams by using FRP materials had increased the load carrying capacity significantly.

  7. Flexural strengthening of Reinforced Concrete (RC) Beams Retrofitted with Corrugated Glass Fiber Reinforced Polymer (GFRP) Laminates

    Science.gov (United States)

    Aravind, N.; Samanta, Amiya K.; Roy, Dilip Kr. Singha; Thanikal, Joseph V.

    2015-01-01

    Strengthening the structural members of old buildings using advanced materials is a contemporary research in the field of repairs and rehabilitation. Many researchers used plain Glass Fiber Reinforced Polymer (GFRP) sheets for strengthening Reinforced Concrete (RC) beams. In this research work, rectangular corrugated GFRP laminates were used for strengthening RC beams to achieve higher flexural strength and load carrying capacity. Type and dimensions of corrugated profile were selected based on preliminary study using ANSYS software. A total of twenty one beams were tested to study the load carrying capacity of control specimens and beams strengthened with plain sheets and corrugated laminates using epoxy resin. This paper presents the experimental and theoretical study on flexural strengthening of Reinforced Concrete (RC) beams using corrugated GFRP laminates and the results are compared. Mathematical models were developed based on the experimental data and then the models were validated.

  8. Strengthening Reinforced Concrete Beams with CFRP and GFRP

    Directory of Open Access Journals (Sweden)

    Mehmet Mustafa Önal

    2014-01-01

    Full Text Available Concrete beams were strengthened by wrapping the shear edges of the beams twice at 45° in opposite directions by either carbon fiber reinforced polymer (CFRP or glass fiber reinforced polymer (GFRP. The study included 3 CFRP wrapped beams, 3 GFRP wrapped beams, and 3 control beams, all of which were 150 × 250 × 2200 mm and manufactured with C20 concrete and S420a structural steel at the Gazi University Technical Education Faculty labs, Turkey. Samples in molds were cured by watering in the open air for 21 days. Four-point bending tests were made on the beam test specimens and the data were collected. Data were evaluated in terms of load displacement, bearing strength, ductility, and energy consumption. In the CFRP and GFRP reinforced beams, compared to controls, 38% and 42%, respectively, strength increase was observed. In all beams, failure-flexural stress occurred in the center as expected. Most cracking was observed in the flexural region 4. A comparison of CFRP and GFRP materials reveals that GFRP enforced parts absorb more energy. Both materials yielded successful results. Thicker epoxy application in both CFRP and GFRP beams was considered to be effective in preventing break-ups.

  9. Shear strengthening of reinforced concrete beams by means of vertical prestressed reinforcement

    OpenAIRE

    Santos Ferreira, Denise Carina; Bairán García, Jesús Miguel; Marí Bernat, Antonio Ricardo

    2016-01-01

    Strengthening reinforced concrete (RC) elements critical to shear with prestressed transversal reinforcement can be an efficient method to increase the shear resistance of structures, allowing the development of the full flexural capacity. However, research on the performance of this technique is very limited, and methods for designing the optimum amount of prestressed transversal reinforcement and assessing the retrofitted structure have not been produced yet. Nonlinear finite element models...

  10. Experimental analysis of reinforced concrete columns strengthened with Self-Compacting concrete

    Directory of Open Access Journals (Sweden)

    M. Y. M. Omar

    Full Text Available This paper presents the results of reinforced concrete columns strengthened by addition of a self-compacting concrete overlay at the compressed and at the tensioned face of the member, with and without addition of longitudinal steel bars. Eight columns were submit- ted to loading with an initial eccentricity of 60 mm . These columns had 120 mm x 250 mm of rectangular cross section, 2000 mm in length and four longitudinal reinforcement steel bars with 10 mm in diameter. Reference columns P1 and P2 were tested to failure without any type of rehabilitation. Columns P3 to P8 were loaded to a predefined load (close to the initial yield point of tension reinforce- ment, then unloaded and strengthened for a subsequent test until failure. Results showed that the method of rehabilitation used was effective, increasing the loading capacity of the strengthened pieces by 2 to 5 times the ultimate load of the reference column.

  11. Moment redistribution in continuous reinforced concrete beams strengthened with carbon-fiber-reinforced polymer laminates

    Science.gov (United States)

    Aiello, M. A.; Valente, L.; Rizzo, A.

    2007-09-01

    The results of tests on continuous steel-fiber-reinforced concrete (RC) beams, with and without an external strengthening, are presented. The internal flexural steel reinforcement was designed so that to allow steel yielding before the collapse of the beams. To prevent the shear failure, steel stirrups were used. The tests also included two nonstrengthened control beams; the other specimens were strengthened with different configurations of externally bonded carbon-fiber-reinforced polymer (CFRP) laminates. In order to prevent the premature failure from delamination of the CFRP strengthening, a wrapping was also applied. The experimental results obtained show that it is possible to achieve a sufficient degree of moment redistribution if the strengthening configuration is chosen properly, confirming the results provided by two simple numerical models.

  12. Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer-Part Ⅰ: Experimental study

    Institute of Scientific and Technical Information of China (English)

    HUANG Yue-lin; WU Jong-hwei; YEN Tsong; HUNG Chien-hsing; LIN Yiching

    2005-01-01

    This work is aimed at studying the strengthening of reinforced concrete (R. C.) beams using prestressed glass fiber-reinforced polymer (PGFRP). Carbon fiber-reinforced polymer (CFRP) has recently become popular for use as repair or rehabilitation material for deteriorated R. C. structures, but because CFRP material is very stiff, the difference in CFRP sheet and concrete material properties is not favorable for transferring the prestress from CFRP sheets to R. C. members. Glass fiber-reinforced polymer (GFRP) sheets with Modulus of Elasticity quite close to that of concrete was chosen in this study. The load-carrying capacities (ultimate loads) and the deflections of strengthened R. C. beams using GFRP and PGFRP sheets were tested and compared. T- and ⊥-shaped beams were used as the under-strengthened and over-strengthened beams. The GFRP sheets were prestressed to one-half their tensile capacities before being bonded to the T- and l-shaped R. C. beams. The prestressed tension in the PGFRP sheets caused cambers in the R. C. beams without cracks on the tensile faces. The PGFRP sheets also enhanced the load-carrying capacity. The test results indicated that T-shaped beams with GFRP sheets increased in load-carrying capacity by 55% while the same beams with PGFRP sheets could increase load-carrying capacity by 100%. The ⊥-shaped beams with GFRP sheets could increase load-carrying capacity by 97% while the same beams with PGFRP sheets could increase the loading-carrying capacity by 117%. Under the same external loads, beams with GFRP sheets underwent larger deflections than beams with PGFRP sheets. While GFRP sheets strengthen R. C. beams, PGFRP sheets decrease the beams' ductility, especially for the over-strengthened beams (⊥-shaped beams).

  13. Strengthening reinforced concrete beams using prestressed glass fiber-reinforced polymer-Part Ⅱ: Analytical study

    Institute of Scientific and Technical Information of China (English)

    HUANG Yue-lin; HUNG Chien-hsing; YEN Tsong; WU Jong-hwei; LIN Yiching

    2005-01-01

    Strengthening reinforced concrete (R. C.) beams using prestressed glass fiber-reinforced polymer (PGFRP) was studied experimentally as described in Part Ⅰ of this paper (Huang et al., 2005). In that paper, R. C. beams, R. C. beams with GFRP(glass fiber-reinforced polymer) sheets, and R. C. beams with PGFRP sheets were tested in both under-strengthened and over-strengthened cases. The test results showed that the load-carrying capacities (ultimate loads) of the beams with GFRP sheets were greater than those of the beams without polymer sheets. The load-carrying capacities of beams with PGFRP sheets were greater than those of beams with GFRP sheets. The objective of this work is to develop an analytical method to compute all of these load-carrying capacities. This analytical method is independent of the experiments and based only on the traditional R. C.and P. C. (prestressed concrete) theory. The analytical results accorded with the test results. It is suggested that this analytical method be used for analyzing and designing R. C. beams strengthened using GFRP or PGFRP sheets.

  14. Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer

    Institute of Scientific and Technical Information of China (English)

    HU Kexu; HE Guisheng; LU Fan

    2007-01-01

    In this paper,two reinforced concrete (RC) beams strengthened with carbon fiber reinforced polymer (CFRP)and attached with thick-painted fire resistant coating were tested for fire resistance following the standard fire testing procedures.The experimental results show that the specimen pasted with the insulated layer of 50 mm in thickness could resist fire for 2.5 h.It is also demonstrated that the steel wire mesh embedded in the insulated layer can effectively prevent it from cracking and eroding under firing.

  15. Strengthening of reinforced concrete circular columns using glass fibre reinforced polymers

    Directory of Open Access Journals (Sweden)

    Manish kumar Tiwari

    2014-04-01

    Full Text Available Seismic retrofitting of reinforced concrete members vulnerable to strong earthquakes is a great problem. It has long been recognized that confinement to concrete compression members not only increase the strength but improve ductility significantly. The present study focuses on the behavior of reinforced concrete specimens strengthened using glass fiber reinforced polymer (GFRP subjected to axial compressive loading. In this study specimen of circular cross section having length to diameter ratio of 2.0 and 0.96% longitudinal reinforcement were prepared and tested for 28 days compressive strength. The specimens were wrapped with 0,2,4,6 and 8 layers of GFRP outside the surface of the specimens as confinement. The test results showed that there is a significant increase in the strength of specimen with the increase of confinement layers on the specimen. The 28 days compressive strength of specimen wrapped with 8 layers of GRRP was increased by 47% as compared to the strength of specimen without any confinement.

  16. Shear strengthening of pre-damaged reinforced concrete beams with carbon fiber reinforced polymer sheet strips

    Institute of Scientific and Technical Information of China (English)

    Feras ALZOUBI; ZHANG Qi; LI Zheng-liang

    2007-01-01

    This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with side-bonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in ACI-440 and fib European code were compared with the experimental results.

  17. Strut Deformation in CFRP-Strengthened Reinforced Concrete Deep Beams

    Directory of Open Access Journals (Sweden)

    Mohammad Panjehpour

    2014-01-01

    Full Text Available Strut-and-tie model (STM method evolved as one of the most useful designs for shear critical structures and discontinuity regions (D-regions. It provides widespread applications in the design of deep beams as recommended by many codes. The estimation of bottle-shaped strut dimensions, as a main constituent of STM, is essential in design calculations. The application of carbon fibre reinforced polymer (CFRP as lightweight material with high tensile strength for strengthening D-regions is currently on the increase. However, the CFRP-strengthening of deep beam complicates the dimensions estimation of bottle-shaped strut. Therefore, this research aimed to investigate the effect of CFRP-strengthening on the deformation of RC strut in the design of deep beams. Two groups of specimens comprising six unstrengthened and six CFRP-strengthened RC deep beams with the shear span to the effective depth ratios (a/d of 0.75, 1.00, 1.25, 1.50, 1.75, and 2.00 were constructed in this research. These beams were tested under four-point bending configuration. The deformation of struts was experimentally evaluated using the values of strain along and perpendicular to the strut centreline. The evaluation was made by the comparisons between unstrengthened and CFRP-strengthened struts regarding the widening and shortening. The key variables were a/d ratio and applied load level.

  18. Strengthening of Corrosion-Damaged Reinforced Concrete Beams with Glass Fiber Reinforced Polymer Laminates

    Directory of Open Access Journals (Sweden)

    A. L. Rose

    2009-01-01

    Full Text Available Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as a reference. Two beams were corroded to serve as a corroded control. A reinforcement mass loss of approximately 10 and 25% were used to define medium and severe degrees of corrosion. The remaining two beams corroded and strengthened with GFRP. Results: The test parameters included first crack load, first crack deflection, yield load, yield deflection, service load, service deflection, ultimate load and ultimate deflection. Based on the results it was found that GFRP Laminates had beneficial effects even at the corrosion-damaged stage. Conclusion/Recommendations: The UDCGFRP laminated beams showed distinct enhancement in ultimate strength and ductility by 72.37 and 49.49% respectively.

  19. Strengthening of concrete structures using carbon fibre reinforced polymers and cement-based adhesives

    OpenAIRE

    Hashemi, Siavash

    2017-01-01

    The research project conducted in this study concerns the investigation of the application of cement-based adhesives in CFRP strengthening of reinforced concrete members. The results demonstrate that mineral-based adhesives can provide the desired matrices for CFRP reinforcement. The literature review covers the background of CFRP application with conventional techniques. The bond characteristics of CFRP to concrete substrate, the flexural performance of retrofitted RC beams, and the fa...

  20. Energy Dissipation Capacity of Reinforced Concrete Beams Strengthened with CFRP Strips

    Science.gov (United States)

    Hong, Sungnam; Park, Sun-Kyu

    2016-05-01

    Cyclic loading tests were performed to investigate the energy dissipation capacities of reinforced concrete (RC) beams strengthened with carbon-fiber-reinforced polymer (CFRP) strips. Four RC beams were manufactured and three-point loaded. Responses of the strengthened beams to the cyclic loadings were measured, including deflections at the center of their span and strains of the CFRP strips and reinforcing steel rebars. Based on test results, the energy dissipation capacity of the strengthened beams were evaluated in comparison with that of an unstrengthened control beam.

  1. Numerical Study Of The Effects Of Preloading, Axial Loading And Concrete Shrinkage On Reinforced Concrete Elements Strengthened By Concrete Layers And Jackets

    Science.gov (United States)

    Lampropoulos, A. P.; Dritsos, S. E.

    2008-07-01

    In this study, the technique of seismic strengthening existing reinforced concrete columns and beams using additional concrete layers and jackets is examined. The finite element method and the finite element program ATENA is used in this investigation. When a reinforced jacket or layer is being constructed around a column it is already preloaded due to existing service loads. This effect has been examined for different values of the axial load normalized to the strengthened column. The techniques of strengthening with a concrete jacket or a reinforced concrete layer on the compressive side of the column are examined. Another phenomenon that is examined in this study is the shrinkage of the new concrete of an additional layer used to strengthen an existing member. For this investigation, a simply supported beam with an additional reinforced concrete layer on the tensile side is examined. The results demonstrate that the effect of preloading is important when a reinforced concrete layer is being used with shear connectors between the old and the new reinforcement. It was also found that the shrinkage of the new concrete reduces the strength of the strengthened beam and induces an initial sliding between the old and the new concrete.

  2. DUCTILITY BEHAVIOR FIBER REINFORCED CONCRETE BEAMS STRENGTHENED WITH EXTERNALLY BONDED GLASS FIBER REINFORCED POLYMER LAMINATES

    Directory of Open Access Journals (Sweden)

    Mariappan Mahalingam

    2013-01-01

    Full Text Available The study presents the results of an experimental investigation conducted on Steel Fiber Reinforced Concrete (SFRC beams with externally bonded Glass Fiber Reinforced Polymer (GFRP laminates with a view to study their strength and ductility. A total of ten beams, 150×250 mm in cross-section were tested in the laboratory over an effective span of 2800 mm. Three fiber reinforced concrete beams were used as reference beams. Six fiber reinforced concrete beams were provided with externally bonded GFRP laminates. One concrete beam was left virgin without any fiber reinforcement and external GFRP laminates. All the beams were tested until failure. The variables considered included volume fraction of fiber reinforcement and stiffness of GFRP laminates. The static responses of all the beams were evaluated in terms of strength, stiffness and ductility. The test results show that the beams provided with externally bonded GFRP laminates exhibit improved performance over the beams with internal fiber reinforcement.

  3. Study of a reinforced concrete beam strengthened using a combination of SMA wire and CFRP plate

    Science.gov (United States)

    Liu, Zhi-qiang; Li, Hui

    2006-03-01

    Traditional methods used for strengthening of reinforced concrete (RC) structures, such as bonding of steel plates, suffer from inherent disadvantages. In recent years, strengthening of RC structures using carbon fiber reinforced polymer (CFRP) plates has attracted considerable attentions around the world. Most existing research on CFRP plate bonding for flexural strengthening of RC beams has been carried out for the strength enhancement. However, little research is focused on effect of residual deformations on the strengthening. The residual deformations have an important effect on the strengthening by CFRP plates. There exists a very significant challenge how the residual deformations are reduced. Shape memory alloy (SMA) has showed outstanding functional properties as an actuator. It is a possibility that SMA can be used to reduce the residual deformation and make cracks of concrete close by imposing the recovery forces on the concrete in the tensile zone. It is only an emergency damage repair since the SMA wires need to be heated continuously. So, an innovative method of a RC beam strengthened by CFRP plates in combination with SMA wires was first investigated experimentally in this paper. In addition, the nonlinear finite element software of ABAQUS was employed to further simulate the behavior of RC beams strengthened through the new strengthening method. It can be found that this is an excellent and effective strengthening method.

  4. Strengthening an in-service reinforcement concrete bridge with prestressed CFRP bars

    Institute of Scientific and Technical Information of China (English)

    Hai-long WANG; Wei-liang JIN; David J.CLELAND; Ai-hui ZHANG

    2009-01-01

    Carbon fiber reinforced polymer(CFRP)bars were prestressed for the structural strengthening of 8 T-shaped rein-forced concrete (RC)beams of a 21-year-old bridge in China.The ultimate bearing capacity of the existing bridge after retrofit was discussed on the basis of concrete structures theory.The flexural strengths of RC beams strengthened with CFRP bars were controlled by the failure of concrete in compression and a prestressing method was applied in the retrofit.The field construction processes of strengthening with CFRP bars-including grouting cracks,cutting groove,grouting epoxy and embedding CFRP bars,surface treating,banding with the U-type CFRP sheets,releasing external prestressed steel tendons-were introduced in detail.In order to evaluate the effectiveness of this strengthening method,field tests using vehicles as live load were applied before and after the retrofit.The test results of deflection and concrete strain of the T-shaped beams with and without strengthening show that the capacity of the repaired bridge,including the bending strength and stiffness,is enhanced.The measurements of crack width also indicate that this strengthening method can enhance the durability of bridges.Therefore,the proposed strengthening technology is feasible and effective.

  5. Numerical Determination of Shear Strength of Steel Reinforced Concrete Column Strengthened by CFRP Sheets

    Institute of Scientific and Technical Information of China (English)

    王铁成; 余流; 王立军

    2003-01-01

    The earthquake-resistant property of reinforced concrete members depends on the interaction between reinforcing bars and surrounding concrete through bond to a large degree. In this paper a general system aimed at dealing with the failure analysis of reinforced concrete columns strengthened with carbon-fiber-reinforced plastic (CFRP) sheets including bond-slip of the anchored reinforcing bars at the foot of the columns is presented. It is based on the yield design theory with a mixed modeling of the structure, according to which the concrete material is treated as a classical two-dimensional continuum, whereas the longitudinal reinforcing bars are regarded as one-dimensional rods including bond-slip at the foot of the columns. In shear reinforced zones both the shear CFRP sheets and transverse reinforcing bars are incorporated in the analysis through a homogenization procedure and they are only in tension. The approach is then implemented numerically by means of the finite-element formulation. The numerical procedure produces accurate estimates for the loading-carrying capacity of the shear members taken as an illustrative application by correlation with the experimental results, so the proposed approach is valid.

  6. Behavior of reinforced concrete columns strengthened by steel jacket

    Directory of Open Access Journals (Sweden)

    Mahmoud F. Belal

    2015-08-01

    Full Text Available RC columns often need strengthening to increase their capacity to sustain the applied load. This research investigates the behavior of RC columns strengthened using steel jacket technique. Three variables were considered; shape of main strengthening system (using angles, C-sections and plates, size and number of batten plates. Behavior and failure load of the strengthened columns were experimentally investigated on seven specimens divided into two un-strengthened specimen and five strengthened ones. A finite element model was developed to study the behavior of these columns. The model was verified and tuned using the experimental results. The research demonstrated that the different strengthening schemes have a major impact on the column capacity. The size of the batten plates had significant effect on the failure load for specimens strengthened with angles, whereas the number of batten plates was more effective for specimens strengthened with C-channels. Then, by using finite element (F.E package ANSYS 12.0 [1] their behavior was investigated, analyzed and verified. Test result showed a good match between both experimental tests and F.E models.

  7. Finite Element Simulation of GFRP Reinforced Concrete Beam Externally Strengthened With CFRP Plates

    Directory of Open Access Journals (Sweden)

    Salleh Norhafizah

    2017-01-01

    Full Text Available The construction technology now has become more and more advanced allowing the development of new technologies or material to replace the previous one and also solved some of the troubles confronted by construction experts. The Glass Fibre Reinforced Polymer (GFRP composite is an alternative to replace the current usage of steel as it is rust proof and stronger in terms of stiffness compared to steel. Furthermore, GFRP bars have a high strength-to-weight ratio, making them attractive as reinforcement for concrete structures. However, the tensile behavior of GFRP bars is characterized by a linear elastic stress–strain relationship up to failure and, therefore, concrete elements reinforced with GFRP reinforcement exhibit brittle failure without warning. Design codes encourage over-reinforced GFRP design since it is more progressive and leads to a less catastrophic failure with a higher degree of deformability. Moreover, because of GFRP low modulus of elasticity, GFRP reinforced concrete members exhibit larger deflections and wider cracks width than steel reinforced concrete. This aims of this paper is to developed 2D Finite Element (FE models that can accurately simulate the respond on an improvement in the deflection of GFRP reinforced concrete beam externally strengthened with CFRP plates on the tension part of beam. The prediction of flexural response according to RCCSA software was also discussed. It was observed that the predicted FE results are given similar result with the experimental measured test data. Base on this good agreement, a parametric study was the performed using the validation FE model to investigate the effect of flexural reinforcement ratio and arrangement of the beams strengthened with different regions of CFRP plates.

  8. An experimentally based analytical model for the shear capacity of FRP-strengthened reinforced concrete beams

    Science.gov (United States)

    Pellegrino, C.; Modena, C.

    2008-05-01

    This paper deals with the shear strengthening of Reinforced Concrete (RC) flexural members with externally bonded Fiber-Reinforced Polymers (FRPs). The interaction between an external FRP and an internal transverse steel reinforcement is not considered in actual code recommendations, but it strongly influences the efficiency of the shear strengthening rehabilitation technique and, as a consequence, the computation of interacting contributions to the nominal shear strength of beams. This circumstance is also discussed on the basis of the results of an experimental investigation of rectangular RC beams strengthened in shear with "U-jacketed" carbon FRP sheets. Based on experimental results of the present and other investigations, a new analytical model for describing the shear capacity of RC beams strengthened according to the most common schemes (side-bonded and "U-jacketed"), taking into account the interaction between steel and FRP shear strength contributions, is proposed.

  9. Deflection analysis of reinforced concrete beams strengthened with carbon fibre reinforced polymer under long-term load action

    Institute of Scientific and Technical Information of China (English)

    Mykolas DAUGEVI(C)IUS; Juozas VALIVONIS; Gediminas MAR(C)IUKAITIS

    2012-01-01

    This paper presents the results of an experimental research on reinforced concrete beams strengthened with an external carbon fibre reinforced polymer (CFRP) layer under long-term load action that lasted for 330 d.We describe the characteristics of deflection development of the beams strengthened with different additional anchorages of the external carbon fibre composite layer during the period of interest.The conducted experiments showed that the additional anchorage influences the slip of the extemal layer with respect to the strengthened element.Thus,concrete and carbon fibre composite interface stiffness decreases with a long-term load action.Therefore,the proposed method of analysis based on the built-up-bars theory can be used to estimate concrete and carbon fibre composite interface stiffness in the case of long-term load.

  10. Near Surface Mounted Composites for Flexural Strengthening of Reinforced Concrete Beams

    Directory of Open Access Journals (Sweden)

    Md. Akter Hosen

    2016-03-01

    Full Text Available Existing structural components require strengthening after a certain period of time due to increases in service loads, errors in design, mechanical damage, and the need to extend the service period. Externally-bonded reinforcement (EBR and near-surface mounted (NSM reinforcement are two preferred strengthening approach. This paper presents a NSM technique incorporating NSM composites, namely steel and carbon fiber-reinforced polymer (CFRP bars, as reinforcement. Experimental and analytical studies carried out to explore the performance of reinforced concrete (RC members strengthened with the NSM composites. Analytical models were developed in predicting the maximum crack spacing and width, concrete cover separation failure loads, and deflection. A four-point bending test was applied on beams strengthened with different types and ratios of NSM reinforcement. The failure characteristics, yield, and ultimate capacities, deflection, strain, and cracking behavior of the beams were evaluated based on the experimental output. The test results indicate an increase in the cracking load of 69% and an increase in the ultimate load of 92% compared with the control beam. The predicted result from the analytical model shows good agreement with the experimental result, which ensures the competent implementation of the present NSM-steel and CFRP technique.

  11. Strengthening of steel–concrete composite girders using carbon fibre reinforced polymer (CFRP) plates

    Indian Academy of Sciences (India)

    S M Mosavi; A Sadeghi Nik

    2015-02-01

    Applying composites in order to strengthen and renew the infrastructures has globally been accepted. Traditional methods to strengthen the out-of-standard structures are costly, time consuming and requires a lot of labour. Today, new techniques are hired using light and strong substances which also resist against corrosion, known as Carbon Fibre Reinforced Polymer (CFRP) plates. Regarding the high tensile strength and proper module of elasticity, CFRP plates are considered as a suitable alternative to strengthen girders. The behaviour of steel–concrete composite girders being statically loaded and strengthened by CFRP plates in this study. The CFRP plates used in this study have been stuck, with epoxy adhesive, under the tensile sections of three steel girders. The results accompanied with analytical study of moment–curvature and numerical analysis done with ANSYS, show that CFRP plates with epoxy adhesive increases the ultimate loading capacity of steel–concrete composite girder. Plastic stiffness of the girders was also increased.

  12. Experimental and analytical behavior of strengthened reinforced concrete columns with steel angles and strips

    Science.gov (United States)

    Khalifa, Essam S.; Al-Tersawy, Sherif H.

    2014-06-01

    The need of strengthening reinforced concrete columns, due to loss of strength and/or stiffness, is an essential requirement due to variation of the loads and environmental conditions applied on these columns. Steel jackets around the reinforced concrete (RC) columns are usually made by means of steel plates covering all over the column surface area. For the value of engineering purposes, another technique was developed using steel angles at the corners of the RC columns connected with discrete steel strips. In this paper, an experimental program is designed to evaluate the improvement in load-carrying capacity, stiffness and ductility of strengthened RC columns, concomitant with steel angles and strips. Despite of prevailing a substantially increased loading capacity and strength a pronounced enhancement in ductility and stiffness has been reported. A need for experimental test results with low value of concrete strength to mimic the local old-age structures condition that required strengthening in local countries. Seven columns specimens are tested to evaluate the strength improvement provided by steel strengthening of columns. The method of strengthened steel angles with strips is compared with another strengthening technique. This technique includes connected and unconnected steel-casing specimens. The observed experimental results describe load-shortening curves, horizontal strains in stirrups and steel strips, as well as description of failure mode. The extra-confinement pressure, due to existence of steel cage, of the strengthened RC column can be also observed from experimental results. The code provisions that predict the load-carrying capacity of the strengthened RC composite column has a discrepancy in the results. For this reason, an analytical model is developed in this paper to compare the code limit with experimental observed results. The proposed model accounts for the composite action for concrete confinement and enhancement of the local buckling

  13. Repairing and Strengthening of an Existing Reinforced Concrete Building: A North Cyprus Perspective

    Directory of Open Access Journals (Sweden)

    Hakan Yalciner

    2010-01-01

    Full Text Available Problem statement: Inadequate attention during design and construction of some of Reinforced Concrete (RC buildings in North Cyprus has raised questions about the performance level of these existing buildings under future earthquakes. Approach: Column jacketing, adding steel braces and new shear walls to an existing building are common strengthening methods used by practical engineers in North Cyprus to increase the performance level of an existing building. Results: The aim of this study was to determine the most effective strengthening method among these three mentioned techniques. As a case study, a four stories RC existing building was selected and assessed using finite element method. To remodel of the existing building, the survey works done included three main steps, detecting the reinforcement bars for beams and columns, actual used concrete strength and soil type. The beams and columns reinforcement bars were determined using Ferro scan method and the soil was sampled in Girne city to determine the soil type. The actual concrete strength was determined using core test. Three common strengthening techniques mentioned above, were applied to the existing building. Then the efficiency of each strengthening method was investigated on the basis of removing of weak columns, not-safe beam-column joints in shear and performance levels based on the FEMA356 and Turkish earthquake code. Conclusion/Recommendations: Results showed that column jacketing is the most effective method to remove the weak columns and not-safe column-beam joints in shear. Nonlinear static pushover results showed that despite that adding shear walls caused an increase in the structural base shear and a reduction in the maximum roof displacement and the number of collapsed elements at FEMA356 performance point, but it caused a remarkable reduction in the building ductility ratio. Finally, results showed that the column jacketing is the most effective and the most economic

  14. An Experimental Study on Strengthening of Reinforced Concrete Flexural Members using Steel Wire Mesh

    Directory of Open Access Journals (Sweden)

    Al Saadi Hamza Salim Mohammed

    2017-01-01

    Full Text Available One of the major challenges and contemporary research in the field of structural engineering is strengthening of existing structural elements using readily available materials in the market. Several investigations were conducted on strengthening of various structural components using traditional and advanced materials. Many researchers tried to enhance the reinforced concrete (RC beams strength using steel plate, Glass and Carbon Fibre Reinforced Polymers (GFRP & CFRP. For the reason that high weight to the strength ratio and compatibility in strength between FRP composites and steel bars, steel plates and GFRP and CFRP composites are not used for strengthening works practically. Hence, in this present work the suitability of using wire mesh for the purpose of strengthening the RC flexural members is studied by conducting experimental works. New technique of strengthening system using wire mesh with a view to improve sectional properties and subsequently flexural strength of RC beams is adopted in this work. The results for experimental and theoretical analysis were compared and found that good correlation exists between them. The experimental results indicate that RC beams strengthened with steel wire mesh are easy technique for strengthening of existing flexural members.

  15. Design aid for shear strengthening of reinforced concrete T-joints using carbon fiber reinforced plastic composites

    Science.gov (United States)

    Gergely, Ioan

    The research presented in the present work focuses on the shear strengthening of beam column joints using carbon fiber composites, a material considered in seismic retrofit in recent years more than any other new material. These composites, or fiber reinforced polymers, offer huge advantages over structural steel reinforced concrete or timber. A few of these advantages are the superior resistance to corrosion, high stiffness to weight and strength to weight ratios, and the ability to control the material's behavior by selecting the orientation of the fibers. The design and field application research on reinforced concrete cap beam-column joints includes analytical investigations using pushover analysis; design of carbon fiber layout, experimental tests and field applications. Several beam column joints have been tested recently with design variables as the type of composite system, fiber orientation and the width of carbon fiber sheets. The surface preparation has been found to be critical for the bond between concrete and composite material, which is the most important factor in joint shear strengthening. The final goal of this thesis is to develop design aids for retrofitting reinforced concrete beam column joints. Two bridge bents were tested on the Interstate-15 corridor. One bent was tested in the as-is condition. Carbon fiber reinforced plastic composite sheets were used to externally reinforce the second bridge bent. By applying the composite, the displacement ductility has been doubled, and the bent overall lateral load capacity has been increased as well. The finite element model (using DRAIN-2DX) was calibrated to model the actual stiffness of the supports. The results were similar to the experimental findings.

  16. Strengthening of non-seismically detailed reinforced concrete beam–column joints using SIFCON blocks

    Indian Academy of Sciences (India)

    I S Misir; S Kahraman

    2013-02-01

    This article aims to propose a novel seismic strengthening technique for non-seismically detailed beam–column joints of existing reinforced concrete buildings, typical of the pre-1975 construction practice in Turkey. The technique is based on mounting pre-fabricated SIFCON composite corner and plate blocks on joints with anchorage rods. For the experimental part three 2/3 scale exterior beam–column joint specimens were tested under quasi-static cyclic loading. One of them was a control specimen with non-seismic details, and the remaining two with the same design properties were strengthened with composite blocks with different thickness and anchorage details. Results showed that the control specimen showed brittle shear failure at low drift levels, whereas in the strengthened specimens, plastic hinge formation moved away from column face allowing specimens to fail in flexure. The proposed technique greatly improved lateral strength, stiffness, energy dissipation, and ductility.

  17. THEORETICAL MODEL ON INTERFACE FAILURE MECHANISM OF REINFORCED CONCRETE CONTINUOUS BEAM STRENGTHENED BY FRP

    Institute of Scientific and Technical Information of China (English)

    Hong Yuan; Zifeng Lin

    2009-01-01

    Fiber reinforced polymer (FRP) composites are increasingly being used for the re-pair and strengthening of deteriorated concrete structural components through adhesive bonding of prefabricated strips/plates and the wet lay-up of fabric. Interracial bond failure modes have at-tracted the attention of researchers because of the importance. The objective of the present study is to analyse the interface failure mechanism of reinforced concrete continuous beam strength-ened by FRP. An analytical solution has been firstly presented to predict the entire debonding process of the model. The realistic bi-linear bond-slip interfacial law was adopted to study this problem. The crack propagation process of the loaded model was divided into four stages (elastic, elastic-softening, elastic-softening-debonded and softening-debonded stage). Among them, elastic-softening-debonded stage has four sub-stages. The equations are solved by adding suitable stress and displacement boundary conditions. Finally, critical value of bond length is determined to make the failure mechanism in the paper effective by solving the simultaneously linear algebraic equations. The interaction between the upper and lower FRP plates can be neglected if axial stiffness ratio of the concrete-to-plate prism is large enough.

  18. Consumption of carbon fiber plates in the reinforced concrete beams strengthened with CFPs

    Institute of Scientific and Technical Information of China (English)

    BU Liangtao; SONG Li; SHI Chuxian

    2007-01-01

    Four-point bending flexural tests were conducted to one full-size reinforced concrete (RC) beam and three full-size RC beams strengthened with carbon fiber plates (CFPs).The experimental results showed that the consumption of CFP had significant effects on failure modes and the flexural capacity.An analytical procedure,based on the limit failure ode and ductility,was presented to predict the applied area of CFP.An analytical program,based on Smith-Teng model and Cheng-Teng model,was provided to calculate the bonding length of CFP.The test results are used to validate the proposed procedure.The results are also applied to the design and construction of RC beam strengthened with CFP.

  19. Modification of strut effectiveness factor for reinforced concrete deep beams strengthened with CFRP laminates

    Directory of Open Access Journals (Sweden)

    Panjehpour, M.

    2014-05-01

    Full Text Available This paper proposes a method to modify the strut effectiveness factor in the strut-and-tie model for CFRP-strengthened reinforced concrete deep beams. Two groups of deep beams comprising six ordinary reinforced concrete deep beams and six CFRP-strengthened reinforced concrete deep beams were experimentally tested under the four-point bending configuration. The shear span-to-effective depth ratio of the beams in each group was 0.75, 1.00, 1.25, 1.50, 1.75, and 2.00. The theoretical principal tensile strain in CFRP-strengthened struts was modified based on a proposed empirical relationship, based on two ratios: the experimental to the theoretical value of principal tensile strain and the shear span-to-effective depth of deep beams.En este trabajo se propone un método en el que se modifica el factor de eficacia que se aplica a las bielas en el modelo de bielas y tirantes para vigas de canto de hormigón reforzadas con laminados CFRP (polímero reforzado con fibras de carbono. Mediante el ensayo a cuatro puntos se determina la resistencia a flexotracción de doce vigas de canto divididas en dos grupos de seis, las del primer grupo de hormigón armado normal y las del segundo de hormigón reforzado con laminados de CFRP. En ambos grupos cada una de las seis vigas se caracteriza por una relación luz de cortante-canto útil distinta, con valores utilizados de: 0.75, 1.00, 1.25, 1.50, 1.75, y 2.00. El valor teórico de la deformación principal por tracción de la biela reforzada con CFRP se modifica de acuerdo con la relación empírica propuesta en este trabajo. Esta se establece a partir de otras dos: la relación entre los valores experimental y teórico de la deformación por tracción principal y la relación luz de cortante-canto útil de las vigas de canto.

  20. Flexural rigidity evolvement laws of reinforced concrete beams strengthened with carbon fiber laminates

    Institute of Scientific and Technical Information of China (English)

    NIU Peng-zhi; HUANG Pei-yan; DENG Jun; HAN Qiang

    2007-01-01

    Extensive research has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suitable for improving the fatigue behavior of reinforced concrete (RC) beams. This paper presents the research on flexural rigidity evolvement laws by testing 14 simple-supported RC beams strengthened with carbon fiber laminates (CFL) under cyclic load, and 2 under monotone load as a reference. The cyclic load tests revealed the peak load applied onto the surface of a supported RC beam strengthened with CFL is linear to the logarithm of its fatigue life, and the flexural rigidity evolvement undergoes three distinct phases: a rapid decrease from the start to about 5% of the fatigue life; an even development from 5% to about 99% of the fatigue life; and a succedent rapid decrease to failure. When the ratio of fatigue cycles to the fatigue life is within 0.05 to 0.99, the flexural rigidity varies linearly with the ratio. The peak load does not affect the flexural rigidity evolvement if it is not high enough to make the main reinforcements yield. The dependences of the flexural rigidity of specimens formed in the same group upon their fatigue cycles normalized by fatigue life are almost coincident. This implies the flexural rigidity may be a material parameter independent of the stress level. These relationships of flexural rigidity to fatigue cycles, and fatigue life may be able to provide some hints for fatigue design and fatigue life evaluation of RC member strengthened with CFL; nevertheless the findings still need verifying by more experiments.

  1. Average Frequency – RA Value for Reinforced Concrete Beam Strengthened with Carbon Fibre Sheet

    Directory of Open Access Journals (Sweden)

    Mohamad M. Z.

    2016-01-01

    Full Text Available Acoustic Emission (AE is one of the tools that can be used to detect the crack and to classify the type of the crack of reinforced concrete (RC structure. Dislocation or movement of the material inside the RC may release the transient elastic wave. In this situation, AE plays important role whereby it can be used to capture the transient elastic wave and convert it into AE parameters such as amplitude, count, rise time and duration. Certain parameter can be used directly to evaluate the crack behavior. But in certain cases, the AE parameter needs to add and calculate by using related formula in order to observe the behavior of the crack. Using analysis of average frequency and RA value, the crack can be classified into tensile or shear cracks. In this study, seven phases of increasing static load were used to observe the crack behavior. The beams were tested in two conditions. For the first condition, the beams were tested in original stated without strengthened with carbon fibre sheet (CFS at the bottom of the beam or called as tension part of the beam. For the second condition, the beams were strengthened with CFS at the tension part of the beam. It was found that, beam wrapped with CFS enhanced the strength of the beams in term of maximum ultimate load. Based on the relationship between average frequency (AF and RA value, the cracks of the beams can be classified.

  2. Semiempirical Methodology for Estimating the Service Life of Concrete Deck Panels Strengthened with Fiber-Reinforced Polymer

    Directory of Open Access Journals (Sweden)

    Eon-Kyoung Kim

    2014-01-01

    Full Text Available Deterioration of concrete bridge decks affects their durability, safety, and function. It is therefore necessary to conduct structural rehabilitation of damaged concrete decks by strengthening them with fiber-reinforced polymer. Of the recent studies on the strengthened structures, most have focused on static behavior; only a few studies have investigated fatigue behavior. Accurate analysis of fatigue in concrete deck performance requires a more realistic simulated moving load. This study developed a theoretical live-load model to reflect the effect of moving vehicle loads, based on a statistical approach to the measurement of real traffic loads over various time periods in Korea. It assessed the fatigue life and strengthening effect of bridge decks strengthened with either carbon fiber sheets or grid carbon fiber polymer plastic using probabilistic and reliability analyses. It used extrapolations and simulations to derive maximum load effects for time periods ranging from 1 day to 75 years. Limited fatigue tests were conducted and probabilistic and reliability analyses were carried out on the strengthened concrete bridge deck specimens to predict the extended fatigue life. Analysis results indicated that strengthened concrete decks provide sufficient resistance against increasing truck loads during the service life of a bridge.

  3. Static and dynamic experimental study of strengthened reinforced short concrete corbel by using carbon fabrics, crack path in shear zone

    Directory of Open Access Journals (Sweden)

    I. Ivanova

    2015-10-01

    Full Text Available The paper presents an experimental analysis of tracking the path of the cracks and crack growth in strengthened or repair reinforced concrete short corbels bonded by carbon fiber fabrics under static and dynamic loads. The reinforced short concrete corbel is a used precast element, for industrial buildings and structures. In fact, their functioning interestingly unconventional is compared to classical beam type elements. Then the effects of bending and shearing are combined in this case. The horizontal reinforced steel is localized to resist to tensile strength induced in bending top and a transversal strength-absorbing contribution. The introduction of carbon fiber composite in the field of Civil Engineering allows to strengthen or repair reinforced concrete structures using adhesive. So the carbon fiber material has many advantages as its low weight, flexibility, easier handling and also interesting physicochemical properties. However maintenance of civil engineering works is to protect them by ensuring better sealing or limiting corrosion. Then strengthening is to repair structures by using bonding technique to compensate their rigidity loss and limit the cracking. This allows to improve their performance and durability. Bonding of composite material in tensile zone of corbel retrieves most tensile stress and allows the structure to extend their load-bearing capacity. The local behavior of the structure is measured by means of the extensometer technique based on electrical strain gauges. This technique allowed to measure strains of steel, carbon fiber fabrics and concrete. The results of this investigation showed that strengthened reinforced concrete corbel bonded by carbon fiber fabrics can improve the ultimate load to twice and stiffens less than a third. The ultimate load, strain and displacement of the specimen are compared to reference experimental model of monotonic and cyclic applied loads. The success of strengthening depends strongly

  4. Pretreatment of Woven Jute FRP Composite and Its Use in Strengthening of Reinforced Concrete Beams in Flexure

    Directory of Open Access Journals (Sweden)

    Tara Sen

    2013-01-01

    Full Text Available Environmental awareness motivates researchers worldwide to perform studies of natural fibre reinforced polymer composites, as they come with many advantages and are primarily sustainable. The present study aims at evaluating the mechanical characteristics of natural woven jute fibre reinforced polymer (FRP composite subjected to three different pretreatments, alkali, benzyl chloride, and lastly heat treatment. It was concluded that heat treatment is one of the most suitable treatment methods for enhancing mechanical properties of jute FRP. Durability studies on Jute FRP pertaining to some common environmental conditions were also carried out such as effect of normal water and thermal aging on the tensile strength of jute FRP followed by fire flow test. The heat treated woven jute FRP composites were subsequently used for flexural strengthening of reinforced concrete beams in full and strip wrapping configurations. The study includes the effect of flexural strengthening provided by woven jute FRP, study of different failure modes, load deflection behavior, effect on the first crack load, and ultimate flexural strength of concrete beams strengthened using woven jute FRP subjected to bending loads. The study concludes that woven jute FRP is a suitable material which can be used for flexural upgradation of reinforced concrete beams.

  5. Effects of the Amount and Shape of Carbon Fiber-Reinforced Polymer Strengthening Elements on the Ductile Behavior of Reinforced Concrete Beams

    Science.gov (United States)

    Hong, Sungnam

    2014-09-01

    A series of beam tests were performed to evaluate the ductility of reinforced concrete (RC) beams strengthened with carbon-fiber-reinforced polymer (CFRP) elements. A total of nine RC beams were produced and loaded up to failure in three-point bending under deflection control. In addition, the amount and shape of the CFRP elements (plates/sheets) were considered as the key test variables. Test results revealed that the strengthening with CFRP elements in the width direction was more effective than the strengthening across their height. The energy method used in an analysis showed that the energy ratio of the beams strengthened with CFRP plates were half or less than half of the energy ratio of the beams strengthened with CFRP sheets. In addition, the ductility of the beams decreased as the strengthening ratio of the CFRP elements increased.

  6. Strengthening of reinforced concrete beams with basalt-based FRP sheets: An analytical assessment

    Science.gov (United States)

    Nerilli, Francesca; Vairo, Giuseppe

    2016-06-01

    In this paper the effectiveness of the flexural strengthening of RC beams through basalt fiber-reinforced sheets is investigated. The non-linear flexural response of RC beams strengthened with FRP composites applied at the traction side is described via an analytical formulation. Validation results and some comparative analyses confirm soundness and consistency of the proposed approach, and highlight the good mechanical performances (in terms of strength and ductility enhancement of the beam) produced by basalt-based reinforcements in comparison with traditional glass or carbon FRPs.

  7. Experimental research on refractory performance of reinforced concrete beams strengthened with CFRP sheets bonded with an inorganic adhesive

    Institute of Scientific and Technical Information of China (English)

    ZHENG Wen-zhong; WAN Fu-xiong; LI Shi-guang

    2010-01-01

    To meet the requirement of fire endurance for concrete structures strengthened with CFRP sheets,this study develops an inorganic adhesive whose strength at 600℃ is not lower than that at normal room temper ature.The inorganic adhesive is then used to bond CFRP sheets on reinforced concrete beams in order to strengthen them.The fire protection of the CFRP sheets is done using the thick-type fireproofing coatings for tunnel(TFCT)and steel structure(TFCSS)respectively.Four specimens are tested in the furnace together.Specimens are exposed to fire for 1.5 h in according to the ISO834 standard fire curve,and then naturally cooled for 1 h.In the tests,the largest displacements at the mid-span positions of specimens are only from1/1400 to 1/318 of actual span corresponding to the highest temperatures from 300 ℃ to 470 ℃.After the specimens are naturally cooled to the normal temperature and the fireproofing coatings are then removed,it can be seen that the CFRP sheets keep in a good state,which indicates that CFRP sheets can be tightly bonded on the concrete and work well together with the concrete beams during and after fire.Besides,the tests also verify that the fire performance of TFCT is superior to TFCSS for the strengthened beams.

  8. Post-strengthening of reinforced concrete beams with prestressed CFRP strips: part 2: analysis under cyclic loading

    Directory of Open Access Journals (Sweden)

    M. R. Garcez

    Full Text Available Different FPR post-strengthening techniques have been developed and applied in existing structures aiming to increase their load capacity. Most of the FRP systems used nowadays consist of carbon fibers embedded in epoxy matrices (CFRP. Regardless of the advantages and the good results shown by the CFRP post-strengthen technique, experimental studies show that, in most cases, the failure of post-strengthened structures is premature. Aiming to better use the tensile strength of the carbon fiber strips used as post-strengthening material, the application of prestressed CFRP strips started to be investigated. The main purpose of this paper is to analyze the effects of the composite prestressing in the performance of the CFRP post strengthening technique. The experimental program was based on flexural tests on post-strengthened reinforced concrete beams subjected to static - part 1 and cyclic - part 2 loading. Experimental results allowed the analysis of the quality and shortcomings of post-strengthen system studied, which resulted in valuable considerations about the analyzed post-strengthened beams.

  9. Long-term Test Arrangement for Externally Strengthened Reinforced Concrete Elements

    Directory of Open Access Journals (Sweden)

    T. Vaňura

    2003-01-01

    Full Text Available Methods for external strengthening of concrete use elements of very high tensional strength glued on to its tensioned surface. These elements may be of metal, carbon fibers (CFRP, glass fibers or others, usually having very good mechanical properties. However, these high-strength elements are normally attached to concrete by epoxy resins. Epoxy resins have a low Young`s modulus and therefore a higher rate of creep may have an influence on the long-term behavior of such external strengthening. In order to verify this idea experimentally a special space-saving arrangement of tests is described in this paper. Panels act as loaded beams but simultaneously as a load for the other panels in a stand. The different load magnitude acting on a different layer of panels should make it possible to study the long-term influence of the degree of shear force on the glue creep. Certainly, the glue creep may be dependent on the type of epoxy resin; therefore several epoxy resin types are included in the tests.

  10. Numerical simulation of tests for the evaluation of the performance of the reinforced concrete slabs strengthening by FRCM

    Directory of Open Access Journals (Sweden)

    Anania Laura

    2016-01-01

    Full Text Available In this work the attention is focused to the numerical simulation of the experimental bending tests carried out on a total of six reinforced concrete r.c. plates the latter aimed to provide a basic understanding of the its performance when strengthened by Fiber Reinforced Cementitius Matrix (FRCM Composites. Three of those were used as control specimens. The numerical simulation was carried out by LUSAS software. A good correlation between the FE results and data obtained from the test, both in the load–deformation behavior and the failure load was highlighted. This permits to prove that applied strengthening system gives back an enhancement 2.5 times greater in respect of the unreinforced case. A greater energy dissipation ability and a residual load-bearing capacity makes the proposed system very useful in the retrofitting as well as in the case of strengthening of bridge structures. Based on the validation of the FE results in bending, the numerical analysis was also extended to characterize the behavior of this strengthening system in tensile.

  11. Nonlinear micromechanics-based finite element analysis of the interfacial behaviour of FRP-strengthened reinforced concrete beams

    Science.gov (United States)

    Abd El Baky, Hussien

    --slip relation is developed considering the interaction between the interfacial normal and shear stress components along the bonded length. A new approach is proposed to describe the entire tau-s relationship based on three separate models. The first model captures the shear response of an orthotropic FRP laminate. The second model simulates the shear characteristics of an adhesive layer, while the third model represents the shear nonlinearity of a thin layer inside the concrete, referred to as the interfacial layer. The proposed bond--slip model reflects the geometrical and material characteristics of the FRP, concrete, and adhesive layers. Two-dimensional and three-dimensional nonlinear displacement-controlled finite element (FE) models are then developed to investigate the flexural and FRP/concrete interfacial responses of FRP-strengthened reinforced concrete beams. The three-dimensional finite element model is created to accommodate cases of beams having FRP anchorage systems. Discrete interface elements are proposed and used to simulate the FRP/concrete interfacial behaviour before and after cracking. The FE models are capable of simulating the various failure modes, including debonding of the FRP either at the plate end or at intermediate cracks. Particular attention is focused on the effect of crack initiation and propagation on the interfacial behaviour. This study leads to an accurate and refined interpretation of the plate-end and intermediate crack debonding failure mechanisms for FRP-strengthened beams with and without FRP anchorage systems. Finally, the FE models are used to conduct a parametric study to generalize the findings of the FE analysis. The variables under investigation include two material characteristics; namely, the concrete compressive strength and axial stiffness of the FRP laminates as well as three geometric properties; namely, the steel reinforcement ratio, the beam span length and the beam depth. The parametric study is followed by a statistical

  12. Flexural strengthening of reinforced concrete beams with carbon fibers reinforced polymer (CFRP sheet bonded to a transition layer of high performance cement-based composite

    Directory of Open Access Journals (Sweden)

    V. J. Ferrari

    Full Text Available Resistance to corrosion, high tensile strength, low weight, easiness and rapidity of application, are characteristics that have contributed to the spread of the strengthening technique characterized by bonding of carbon fibers reinforced polymer (CFRP. This research aimed to develop an innovate strengthening method for RC beams, based on a high performance cement-based composite of steel fibers (macro + microfibers to be applied as a transition layer. The purpose of this transition layer is better control the cracking of concrete and detain or even avoid premature debonding of strengthening. A preliminary study in short beams molded with steel fibers and strengthened with CFRP sheet, was carried out where was verified that the conception of the transition layer is valid. Tests were developed to get a cement-based composite with adequate characteristics to constitute the layer transition. Results showed the possibility to develop a high performance material with a pseudo strain-hardening behavior, high strength and fracture toughness. The application of the strengthening on the transition layer surface had significantly to improve the performance levels of the strengthened beam. It summary, it was proven the efficiency of the new strengthening technique, and much information can be used as criteria of projects for repaired and strengthened structures.

  13. Strain coordination of quasi-plane-hypothesis for reinforced concrete beam strengthened by epoxy-bonded glass fiber reinforced plastic plate

    Institute of Scientific and Technical Information of China (English)

    ZENG Xian-tao; DING Ya-hong; WANG Xing-guo

    2006-01-01

    The testing of thirteen reinforced concrete (RC) beams strengthened by epoxy-bonded glass fiber reinforced plastic plate (GFRP) shows that the RC beam and the GFRP plate with epoxy bonding on it can work fairly well in coordination to each other. But there is relative slipping between RC beam and GFRP plate. And the strain of GFRP and steel rebar of RC beam satisfies the quasi-plane-hypothesis, that is, the strain of longitudinal fiber that parallels to the neutral axis of plated beam within the scope of effective height (h0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. The strain of GFRP and steel rebar satisfies the equation: εCFRP = Kεsteel.

  14. flexural improvement of plain concrete beams strengthened with ...

    African Journals Online (AJOL)

    Muhammad Nura Isa

    strengthened with High Performance Fibre Reinforced Concrete (HPFRC) layer using three different jacketing ... to strengthen existing reinforced concrete (RC) structures ... cylinders in accordance with ASTM C39/C39M-16 and .... the beams based on material test results as input data .... The results show good agreement.

  15. Crack-induced debonding failure in fiber reinforced plastics (FRP) strengthened concrete beams: Experimental and theoretical analysis

    Science.gov (United States)

    Pan, Jinlong

    External bonding of FRP plates to the tension substrate of RC beams has been accepted as an efficient and effective technique for flexural strengthening. In this thesis, different problems related to crack-induced debonding of the FRP plate in the flexural strengthened concrete beams have been investigated. FRP strengthened RC beam may fail by FRP debonding from the bottom of a major flexural crack in the span. This kind of failure is studied with the direct shear test in the present research work. Our experimental investigation focuses on the effect of concrete composition on the bond behavior between FRP and concrete. Based on the test results, the bond capacity of the specimen is found to be governed by the concrete surface tensile strength, aggregate size and aggregate content. Then, the neural network is employed to derive an empirical expression for the interfacial fracture energy in terms of concrete surface tensile strength and aggregate content. Using the empirical equation, simulated bond capacity is in good agreement with experimental results. In the FRP strengthened RC beams, debonding of the FRP plate often occurs under the presence of multiple cracks along the span. In the present thesis, experimental and theoretical investigations are performed to study the effect of multiple secondary cracks on the debonding behavior and ultimate load capacity. A new analytical model for FRP debonding under multiple cracks has been developed. The effect of the multiple secondary cracks on the shear softening in the debonded zone is explicitly considered in the model. Using the new model, the simulated values of ultimate load when debonding occurs are in good agreement with measured values. In the FRP strengthened RC beams, concrete cover separation or plate end debonding can be avoided by applying tapers at the FRP plate end. In this situation, it is easier for FRP debonding to be induced by a major flexural crack close to the support. To study the effect of the

  16. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...

  17. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...... at the limit state of serviceability is in some simple cases determined by setting up the statical and the compatibility conditions.With these moment distributions, the maximum deflection and the reinforcement stresses at the span middle and at a support are calculated.The results are compared with results...

  18. Modeling and characterization of strengthened concrete tension members

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Stang, Henrik

    2011-01-01

    The structural potential for cracking of externally strengthened concrete tension members, can be predicted with three parameters, describing the structural cracking potential based on fracture mechanical properties of the of concrete and interface between concrete and strengthening medium....... With these parameters, it is possible to design reinforcement and obtain a required cracking behavior of a given structure. Design recommendations for single and multiple cracking of the tension specimen are given in terms of fracture mechanical parameters, and a structural stiffness parameter....

  19. Corrosion Inhibitors for Reinforced Concrete

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Steel corrosion in reinforced concrete structures has been a major problem across the U.S. Steel-reinforced concrete structures are continually subject to attack by corrosion brought on by naturally occurring environmental conditions. FerroGard, a corrosion inhibitor, developed by Sika Corporation, penetrates hardened concrete to dramatically reduce corrosion by 65% and extend the structure's service life.

  20. Cellular fiber–reinforced concrete

    OpenAIRE

    Isachenko S.; Kodzoev M.

    2016-01-01

    Methods disperse reinforcement of concrete matrix using polypropylene, glass, basalt and metal fibers allows to make the construction of complex configuration, solve the problem of frost products. Dispersed reinforcement reduces the overall weight of the structures. The fiber replaces the secondary reinforcement, reducing the volume of use of structural steel reinforcement. Cellular Fiber concretes are characterized by high-performance properties, especially increased bending strength and...

  1. Short and long term behaviour of externally bonded fibre reinforced polymer laminates with bio-based resins for flexural strengthening of concrete beams

    Science.gov (United States)

    McSwiggan, Ciaran

    The use of bio-based resins in composites for construction is emerging as a way to reduce of embodied energy produced by a structural system. In this study, two types of bio-based resins were explored: an epoxidized pine oil resin blend (EP) and a furfuryl alcohol resin (FA) derived from corn cobs and sugar cane. Nine large-scale reinforced concrete beams strengthened using externally bonded carbon and glass fibre reinforced bio-based polymer (CFRP and GFRP) sheets were tested. The EP resin resulted in a comparable bond strength to conventional epoxy (E) when used in wet layup, with a 7% higher strength for CFRP. The FA resin, on the other hand, resulted in a very weak bond, likely due to concrete alkalinity affecting curing. However, when FA resin was used to produce prefabricated cured CFRP plates which were then bonded to concrete using conventional epoxy paste, it showed an excellent bond strength. The beams achieved an increase in peak load ranging from 18-54% and a 9-46% increase in yielding load, depending on the number of FRP layers and type of fibres and resin. Additionally, 137 concrete prisms with a mid-span half-depth saw cut were used to test CFRP bond durability, and 195 CFRP coupons were used to examine tensile strength durability. Specimens were conditioned in a 3.5% saline solution at 23, 40 or 50°C, for up to 240 days. Reductions in bond strength did not exceed 15%. Bond failure of EP was adhesive with traces of cement paste on CFRP, whereas that of FA was cohesive with a thicker layer of concrete on CFRP, suggesting that the bond between FA and epoxy paste is excellent. EP tension coupons had similar strength and modulus to E resin, whereas FA coupons had a 9% lower strength and 14% higher modulus. After 240 days of exposure, maximum reductions in tensile strength were 8, 19 and 10% for EP, FA and E resins, respectively. Analysis of Variance (ANOVA) was also performed to assess the significance of the reductions observed. High degrees of

  2. CFRP strengthened openings in two-way concrete slabs

    DEFF Research Database (Denmark)

    Enochsson, O.; Lundqvist, J.; Täljsten, Björn

    2006-01-01

    Rehabilitation and strengthening of concrete structures with externally bonded fibre reinforced polymers (FRPs) has been a viable technique for at least a decade. An interesting and useful application is strengthening of slabs or walls where openings are introduced. In these situations, FRP sheet...

  3. Modelling reinforcement corrosion in concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Geiker, Mette Rica; Stang, Henrik

    2012-01-01

    A physio-chemical model for the simulation of reinforcement corrosion in concrete struc-tures was developed. The model allows for simulation of initiation and subsequent propaga-tion of reinforcement corrosion. Corrosion is assumed to be initiated once a defined critical chloride threshold...... is reached causing the formation of anodic and cathodic regions along the reinforcement. Critical chloride thresholds, randomly distributed along the reinforcement sur-face, link the initiation and propagation phase of reinforcement corrosion. To demonstrate the potential use of the developed model......, a numerical example is pre-sented, that illustrates the formation of corrosion cells as well as propagation of corrosion in a reinforced concrete structure....

  4. Optimization of reinforced concrete slabs

    Science.gov (United States)

    Ferritto, J. M.

    1979-01-01

    Reinforced concrete cells composed of concrete slabs and used to limit the effects of accidental explosions during hazardous explosives operations are analyzed. An automated design procedure which considers the dynamic nonlinear behavior of the reinforced concrete of arbitrary geometrical and structural configuration subjected to dynamic pressure loading is discussed. The optimum design of the slab is examined using an interior penalty function. The optimization procedure is presented and the results are discussed and compared with finite element analysis.

  5. Optimization of reinforced concrete slabs

    Science.gov (United States)

    Ferritto, J. M.

    1979-01-01

    Reinforced concrete cells composed of concrete slabs and used to limit the effects of accidental explosions during hazardous explosives operations are analyzed. An automated design procedure which considers the dynamic nonlinear behavior of the reinforced concrete of arbitrary geometrical and structural configuration subjected to dynamic pressure loading is discussed. The optimum design of the slab is examined using an interior penalty function. The optimization procedure is presented and the results are discussed and compared with finite element analysis.

  6. Seismic Strengthening Effects Based on Pseudodynamic Testing of a Reinforced Concrete Building Retrofitted with a Wire-Woven Bulk Kagome Truss Damper

    Directory of Open Access Journals (Sweden)

    Jae-Sung Hwang

    2016-01-01

    Full Text Available A passive damper with a wire-woven bulk Kagome truss design was recently developed; its applicability as a passive damper to improve the seismic performance of building systems, including shear hysteresis behavior, energy dissipation capacity, and fatigue, was confirmed by material tests. The Kagome truss, a periodic cellular metal type, is composed of evenly distributed helical wires with a constant pitch and helical radius in six directions. The purpose of this study was to develop a new passive damper system for seismic strengthening of existing reinforced concrete (RC frames. The proposed external connection methodology uses a wire-woven bulk Kagome truss (i.e., a Kagome damper external connection (KDEC system, to dissipate earthquake energy using the dynamic interaction among an existing building, a support structure, and the Kagome damper installed between them. Four test specimens were designed and then strengthened with the KDEC system. Cyclic loading and pseudodynamic tests were conducted; lateral load-carrying capacity, deformation, and hysteresis characteristics were investigated, as well as the maximum response strength, response ductility, and earthquake damage degree, and compared to a control sample. Test results revealed that the KDEC system effectively dissipated the earthquake energy, showing considerable resilience under large-scale earthquake conditions.

  7. External reinforcing of fiber concrete constructions by carbon fiber tapes

    OpenAIRE

    S.V. Klyuyev; Yu.V. Guryanov

    2013-01-01

    Strengthening the concrete and reinforced concrete structures with carbon fiber tapes is very actively applied in Europe nowadays. In Russia composites based on carbon fiber have also widely spread recently. The main advantages of these materials for strengthening structures are its high specific strength (strength-weight ratio) and strength-to-density ratio.Experimental studies on strengthening and restoration of the constructions were held. Flexible fiber concrete constructions based on man...

  8. Retrofit Strengthening of a Seismically Inadequate Reinforced Concrete Frame Using Pre-Stressed Cable Bracing Systems and Beam Alteration

    Science.gov (United States)

    1991-01-01

    unbraced subassemblage is shown in Fig. 4.6. In scheme 1 the top layer of negative reinforcement is cut (two #6 bars). The beam moment capacity is reduced...if all primary positive and negative reinforcement is severed. As a result, it is possible to weaken the beams sufficiently to ensure that plastic...at a drift of about 0.3%. The brittleness of the column is improved as well from q - 0.56 to 0.60. In scheme 2 the first layer of negative

  9. CFRP strengthened openings in two-way concrete slabs

    DEFF Research Database (Denmark)

    Enochsson, O.; Lundqvist, J.; Täljsten, Björn

    2006-01-01

    Rehabilitation and strengthening of concrete structures with externally bonded fibre reinforced polymers (FRPs) has been a viable technique for at least a decade. An interesting and useful application is strengthening of slabs or walls where openings are introduced. In these situations, FRP sheets....... In this paper, laboratory tests on I I slabs with openings, loaded with a distributed load are presented together with analytical and numerical evaluations. Six slabs with openings have been strengthened with carbon fibre reinforced polymers (CFRPs) sheets. These slabs are compared with traditionally steel...

  10. Fracture mechanical analysis of strengthened concrete tension members with one crack

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Stang, Henrik

    2012-01-01

    A concrete tension member strengthened 2 with fiber reinforced polymer plates on two sides 3 is analyzed with non-linear fracture mechanics. The 4 analysis of the strengthened tension member incorpo5 rates cohesive properties for both concrete and inter6 face between concrete and strengthening...... the structural classification parameters, is inves13 tigated in a non-dimensional analysis, and found to 14 depend strongly on the ratio between interfacial and 15 concrete fracture energies....

  11. Experimental Study on Seismic Behavior ofSeismic-damaged Lateral Joints in CompositeFrame Consisting of CFSST Columns and SteelBeams Strengthened with Enclosed ReinforcedConcrete

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concrete (RC) at the ends of columns andwelding steel plates at the ends of beams was presented. Based on the current design specifications, one half scaled models of 4lateral joints in composite frame consisting of CFSST columns and steel beams were designed and manufactured. One model wasoriginal control specimen, one was strengthened by enclosed RC, and the others were strengthened after pre-damage. The destructiontests under lateral cyclic load on the models were carried. The effectiveness of seismic-damaged joints strengthened with enclosedRC and the reinforcement effect on different levels of seismic damage were studied. The test results show that seismic- damagedjoints in composite frame consisting of CFSST columns and steel beams strengthened with enclosed RC meets the strongcolumn-weak beam joints requirement of seismic design, and the failure modes are of all joints are the bending failure of steel beam.The reinforcement with enclosed RC has a significant on increasing the ultimate capacity and the seismic behaviors of joints. Thestudy indicated the rehabilitated joints recover the level of their original seismic performances before seismic damage in a certainextent damage level. Based on the test data, namely the ultimate capacity, limit displacement, ductility, the energy consumptioncoefficient, limit displacementthe strengthening method of seismic-damaged joints by strengthened with enclosed RC is an effectivemethod for seismic strengthening.

  12. Retrofitting of Reinforced Concrete Beams using Reactive Powder Concrete (RPC)

    Science.gov (United States)

    Karthik, S.; Sundaravadivelu, Karthik

    2017-07-01

    Strengthening of existing damaged structures is one of the leading studies in civil engineering. The purpose of retrofitting is to structurally treat the member with an aim to restore the structure to its original strength. The focus of this project is to study the behaviour of damaged Reinforced Concrete beam retrofitted with Reactive Powder Concrete (RPC) Overlay. Reinforced concrete beams of length 1200 mm, width 100 mm and depth 200 mm were casted with M30 grade of concrete in the laboratory and cured for 28 days. One beam is taken as control and are tested under two point loading to find out ultimate load. Remaining beams are subjected to 90 % ultimate load of control beams. The partially damaged beams are retrofitted with Reactive Powder Concrete Overlay at the full tension face of the beam and side overlay depends upon the respectable retrofitting techniques with 10 mm and 20 mm thick layer to find optimum. Materials like steel fibres are added to enhance the ductility by eliminating coarse particle for homogeneity of the structure. Finally, the modes of failure for retrofitted beams are analysed experimentally under two point loading & compared the results with Control beam.

  13. Topology optimization of reinforced concrete structures

    DEFF Research Database (Denmark)

    Amir, Oded

    Recent advances regarding topology optimization procedures of reinforced concrete structures are presented. We discuss several approaches to the challenging problem of optimizing the distribution of concrete and steel reinforcement. In particular, the consideration of complex nonlinear constitutive...

  14. 碳纤维布加固混凝土结构的研究现状及展望%Current Study and Development of CFRP-Strengthened Reinforced Concrete Structure

    Institute of Scientific and Technical Information of China (English)

    熊雷; 杨炳; 龚玉云

    2015-01-01

    carbon fiber reinforced polymer ( CFRP ) rein-forcement is a new type of method of reinforcement, which be-longs to the method of fibrous composite. In recent years, CFRP with light weight, high strength and anti-corrosion had been widely used in strengthening the reinforced concrete struc-ture, as a result, the method have achieved good effect. This paper introduces the relevant provisions about CFRP from specifi-cations and the strengthening process about CFRP. In the end, this paper introduces the reinforced concrete structure, joint and column strengthened by CFRP, and make a summing up of the previous research, to provide some suggestions for further re-search.%碳纤维布加固属于纤维复合材料加固法, 是一种新兴的加固方式. 碳纤维布因其轻质、 高强、 耐腐蚀等优点已被广泛应用于钢筋混凝土结构的抗震加固中, 并取得了良好的加固效果. 本文介绍了规范关于碳纤维布的相关规定, 并简述了碳纤维布加固流程, 最后从碳纤维布加固钢筋混凝土框架、 节点、 柱这三个方面进行论述, 对前人的研究进行总结, 以期能为将来的研究提供一些建议.

  15. 内嵌预应力碳纤维筋加固混凝土梁受力性能试验研究%Experimental research on flexural behavior of reinforced concrete beams strengthened with prestressed near surface mounted tendons

    Institute of Scientific and Technical Information of China (English)

    丁亚红; 马艳洁

    2012-01-01

    A technique for increasing the flexural properties of concrete beams strengthened with prestressed carbon fiber in sawed grooves in the concrete cover is studied. Ten beams under monotonic loads were tested. The stressing process, failure capacity, flexural capacity, displacement ductility and deformation were studied. The test shows that the strengthening technique using carbon fiber bonding in the concrete cover can enhance the first-crack load and steel- yielding load of beams compared with the ordinary beam. It is worth noticing that the prestressed carbon fiber can limit the crack width all the way up to failure and improve the service performance of the strengthened beams. It also reduces the deformation of reinforcement and increases yield loads. The high-strength performance of carbon fiber reinforcement can be fully used. With the reinforcement amount and the initial prestressing level increased, ductility will be reduced to some extent. The embedded strengthening method with prestressing carbon fiber reinforcement can effectively solve the problems of existing strengthening method, such as the inadequate use of materials and debonding failure. It is an effective strengthening method.%通过对内嵌预应力碳纤维加固混凝土梁的静力加载试验,对其受力过程、破坏形态、承载力、延性和变形情况进行了分析。试验结果表明:内嵌预应力碳纤维筋加固混凝土梁能大幅度提高被加固梁的开裂荷载和极限荷载,延迟裂缝开展,改善梁的正常使用状态;有效减小加固构件的变形,延缓筋材屈服,充分利用碳纤维筋的高强性能;且随着加固量及初始预应力水平的提高,被加固试件的延性有所降低。内嵌预应力碳纤维筋加固法能有效解决现有加固方法在材料利用不充分,粘结剥离破坏等方面的缺点,是一种行之有效的加固方法。

  16. Timber floors strengthened with concrete

    NARCIS (Netherlands)

    Blass, H.J.; Linden, M.L.R. van der; Schlager, M.

    1998-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are not new (Pokulka, 1997) and form a simple and practical solution, they are not widely adopted. One of the reasons for this is the Jack of uniform design rules. In this research progr

  17. Timber floors strengthened with concrete

    NARCIS (Netherlands)

    Blass, H.J.; Linden, M.L.R. van der; Schlager, M.

    1998-01-01

    Timber-concrete composite (tcc) beams may be used for the renovation of old timber floors. Although these systems are not new (Pokulka, 1997) and form a simple and practical solution, they are not widely adopted. One of the reasons for this is the Jack of uniform design rules. In this research

  18. Research on Seismic Behavior of Corroded and Strengthened Reinforced Concrete Specimens%受腐蚀钢筋混凝土构件抗震加固性能研究

    Institute of Scientific and Technical Information of China (English)

    贡金鑫; 张艳青; 李金波

    2011-01-01

    受腐蚀及加固后钢筋混凝土结构的抗震性能是工程中非常关心的问题.本文介绍了课题组在这方面的研究成果.研究表明,受腐蚀钢筋混凝土构件的承载力、延性和耗能能力均有降低,降低程度与钢筋的锈蚀量有关.对于只用碳纤维布包裹的腐蚀构件,承载力提高不多,但延性和耗能能力有较大提高.对于用碳纤维布和角钢复合加固及碳纤维布和加大截面复合加固的腐蚀构件,承载力、延性和耗能能力均有所提高.%It is important to understanding the seismic behavior of corroded and strengthened reinforced concrete specimens. The experimental results indicate that the bearing capacity, ductility and energy consumption of the corroded reinforced concrete specimens decreased to some content depending on percentage of reinforcement corrosion. There is no essential increase for bearing capacity of the corroded specimen wrap with CFRP except for ductility and energy consumption. However for corroded reinforced concrete strengthened with steel jacket and wrap with CFRP or section enlargement and wrap with CFRP,the bearing capacity, ductility and energy consumption enhance considerably.

  19. Modelling localised fracture of reinforced concrete structures

    OpenAIRE

    Liao, F; Huang, Z.

    2015-01-01

    This paper presents a robust finite element procedure for simulating the localised fracture of reinforced concrete members. In this new model the concrete member is modelled as an assembly of plain concrete, reinforcing steel bar and bond-link elements. The 4-node quadrilateral elements are used for 2D modelling of plain concrete elements, in which the extended finite element method is adopted to simulate the formation and growth of individual cracks. The reinforcing steel bars are modelled b...

  20. Mechanical characterization of fiber reinforced Polymer Concrete

    Directory of Open Access Journals (Sweden)

    João Marciano Laredo dos Reis

    2005-09-01

    Full Text Available A comparative study between epoxy Polymer Concrete plain, reinforced with carbon and glass fibers and commercial concrete mixes was made. The fibers are 6 mm long and the fiber content was 2% and 1%, respectively, in mass. Compressive tests were performed at room temperature and load vs. displacement curves were plotted up to failure. The carbon and glass fibers reinforcement were randomly dispersed into the matrix of polymer concrete. An increase in compressive properties was observed as function of reinforcement. The comparison also showed that Polymer Concrete, plain and reinforced, has a better performance than regular market concrete, suggesting that PC is a reliable alternative for construction industry.

  1. TESTS ON STRUCTURALLY DEFICIENT RC SLABS STRENGTHENED WITH FIBRE REINFORCED POLYMER (FRP) COMPOSITES

    Institute of Scientific and Technical Information of China (English)

    S.T. Smith; S.J. Kim

    2004-01-01

    This paper reports the results of a series of tests on fibre reinforced polymer (FRP) strengthened reinforced concrete (RC) slabs, which were recently undertaken at the University of Technology,Sydney. The slabs were reinforced with high-strength low-ductile steel reinforcement and strengthened with either carbon FRP (CFRP) or glass FRP (GFRP) composites. The unstrengthened control slabs failed by fracture of the steel tension reinforcement while the FRP strengthened slabs failed by debonding of the FRP followed by rupture of the tension steel. The FRP-strengthened slabs were stronger than their unstrengthened counterparts and displayed considerable ductility.

  2. Corrosion of reinforcement bars in steel ibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe

    Steel fibres have been known as an alternative to traditional reinforcement bars for special applications of structural concrete for decades and the use of steel fibre reinforced concrete (SFRC) has gradually increased in recent years. Steel fibres lead to reduced crack widths in concrete formed......, among other reasons, due to shrinkage and/or mechanical loading. Steel fibres are nowadays also used in combination with traditional reinforcement for structural concrete, where the role of the fibres is to minimize the crack widths whereas the traditional reinforcement bars are used for structural....... The aim of the work presented in this Ph.D. thesis was to quantify the influence of steel fibres on corrosion of traditional reinforcement bars embedded in uncracked concrete as well as cracked concrete. Focus of the work was set on the impact of steel fibres on corrosion propagation in uncracked concrete...

  3. Behavior of reinforced concrete beams reinforced with GFRP bars

    Directory of Open Access Journals (Sweden)

    D. H. Tavares

    Full Text Available The use of fiber reinforced polymer (FRP bars is one of the alternatives presented in recent studies to prevent the drawbacks related to the steel reinforcement in specific reinforced concrete members. In this work, six reinforced concrete beams were submitted to four point bending tests. One beam was reinforced with CA-50 steel bars and five with glass fiber reinforced polymer (GFRP bars. The tests were carried out in the Department of Structural Engineering in São Carlos Engineering School, São Paulo University. The objective of the test program was to compare strength, reinforcement deformation, displacement, and some anchorage aspects between the GFRP-reinforced concrete beams and the steel-reinforced concrete beam. The results show that, even though four GFRP-reinforced concrete beams were designed with the same internal tension force as that with steel reinforcement, their capacity was lower than that of the steel-reinforced beam. The results also show that similar flexural capacity can be achieved for the steel- and for the GFRP-reinforced concrete beams by controlling the stiffness (reinforcement modulus of elasticity multiplied by the bar cross-sectional area - EA and the tension force of the GFRP bars.

  4. Delamination of carbon-fiber strengthening layer from concrete beam during deformation (infrared thermography

    Directory of Open Access Journals (Sweden)

    I. N. Shardakov

    2016-10-01

    Full Text Available Technology of strengthening reinforced concrete structures with composite materials has found wide application. The effectiveness of strengthening of concrete structures with externally bonded reinforcement is supported by a great deal of experimental evidence. However, the problem of serviceability of such structures has not been adequately explored. The present work describes the results of experimental studies on the loadcarrying capacity of concrete beams strengthened with carbon fiber reinforced plastic (CFRP. Special emphasis is placed on studying the debonding of the strengthening layer from the concrete surface and analyzing its influence on the load-carrying capacity of beams. Infrared thermography is used to detect the first signs of debonding and to assess the debond growth rate

  5. Behavior of reinforced concrete columns strenghtened by partial jacketing

    Directory of Open Access Journals (Sweden)

    D. B. FERREIRA

    Full Text Available This article presents the study of reinforced concrete columns strengthened using a partial jacket consisting of a 35mm self-compacting concrete layer added to its most compressed face and tested in combined compression and uniaxial bending until rupture. Wedge bolt connectors were used to increase bond at the interface between the two concrete layers of different ages. Seven 2000 mm long columns were tested. Two columns were cast monolithically and named PO (original column e PR (reference column. The other five columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and other columns had a 155 mm by 250mm cross section after the strengthening procedure. Results show that the ultimate resistance of the strengthened columns was more than three times the ultimate resistance of the original column PO, indicating the effectiveness of the strengthening procedure. Detachment of the new concrete layer with concrete crushing and steel yielding occurred in the strengthened columns.

  6. Degradation of Waterfront Reinforced Concrete Structures

    African Journals Online (AJOL)

    Key words: Degradation, reinforced concrete, Dar es Salaam port. Abstract—One of the .... Plate 2. Typical cracks on concrete piers found on berth. 4 through 8. Plate 3. Exposed .... Rubaratuka, I. A. and Mulungu, D., 1999: Defects in reinforced ...

  7. STRUCTURAL PERFORMANCE OF DEGRADED REINFORCED CONCRETE MEMBERS.

    Energy Technology Data Exchange (ETDEWEB)

    Braverman, J.I.; Miller, C.A.; Ellingwood, B.R.; Naus, D.J.; Hofmayer, C.H.; Bezler, P.; Chang, T.Y.

    2001-03-22

    This paper describes the results of a study to evaluate, in probabilistic terms, the effects of age-related degradation on the structural performance of reinforced concrete members at nuclear power plants. The paper focuses on degradation of reinforced concrete flexural members and shear walls due to the loss of steel reinforcing area and loss of concrete area (cracking/spalling). Loss of steel area is typically caused by corrosion while cracking and spalling can be caused by corrosion of reinforcing steel, freeze-thaw, or aggressive chemical attack. Structural performance in the presence of uncertainties is depicted by a fragility (or conditional probability of failure). The effects of degradation on the fragility of reinforced concrete members are calculated to assess the potential significance of various levels of degradation. The fragility modeling procedures applied to degraded concrete members can be used to assess the effects of degradation on plant risk and can lead to the development of probability-based degradation acceptance limits.

  8. Passive Control Reinforced Concrete Frame Mechanism with High Strength Reinforcements and Its Potential Benefits Against Earthquakes

    Institute of Scientific and Technical Information of China (English)

    Asad Ullah Qazi; YE Lieping; LU Xinzheng

    2006-01-01

    Severe earthquakes continue to cause major catastrophes. Many devices in active, hybrid, and semi-active structural control systems which are used as controllable force devices are costly to build and maintain. The passive control reinforced concrete frame (PCRCF) reinforced with high strength steel only in the columns presented here provides structural systems more resistance to lateral earthquake loadings at comparatively lower cost. The effectiveness is demonstrated by a nonlinear static analysis using fiber model for a single story single bay frame. The study shows that the use of high performance steel in columns prevents formation of plastic hinges at the critical column base sections and failures are always initiated by reinforcement yielding at the beam ends. Furthermore, after experiencing severe lateral drift, the passive control design has small residual displacements compared to ordinary reinforced concrete frames. PCRCF rehabilitation and strengthening can be achieved more easily as compared with ordinary reinforced concrete frame.

  9. Lagged strain of laminates in RC beams strengthened with fiber-reinforced polymer

    Institute of Scientific and Technical Information of China (English)

    HE Xue-jun; ZHOU Chao-yang; LI Yi-hui; XU Ling

    2007-01-01

    Based on the theory of concrete structure, a new expression was derived for lagged strain of fiber-reinforced polymer(FRP) laminates in reinforced concrete (RC) beams strengthened with FRP. The influence of different preloaded states and nonlinear stress-strain relationship of compressed concrete were both taken into account in this approach. Then a simplified expression was given by ignoring tensile resistance of concrete. Comparison of analytical predictions with experimental results indicates satisfactory accuracy of the procedures. The errors are less than 8% and 10% respectively when the tensile resistance of concrete is or not considered. While the maximum error of existing procedures is up to 60%.

  10. Computation of reinforcement for solid concrete

    NARCIS (Netherlands)

    Hoogenboom, P.C.J.; De Boer, A.

    2008-01-01

    Reinforcement in a concrete structure is often determined based on linear elastic stresses. This paper considers computation of the required reinforcement when these stresses have been determined by the finite element method with volume elements. Included are both tension reinforcement and compressi

  11. Finite element model of reinforcement corrosion in concrete

    Institute of Scientific and Technical Information of China (English)

    Jin-xia XU; Lin-hua JIANG; Qi WANG

    2009-01-01

    A nonlinear finite element model (FEM) of the corrosion of steel reinforcement in concrete has been successfully developed on the basis of mathematical analysis of the electrochemical process of steel corrosion in concrete. The influences of the area ratio and the Tafel constants of the anode and cathode on the potential and corrosion current density have been examined with the model. It has been found that the finite element calculation is more suitable for assessing the corrosion condition of steel reinforcement than ordinary electrochemical techniques due to the fact that FEM can obtain the distributions of potential and corrosion current density on the steel surface. In addition, the local corrosion of steel reinforcement in concrete is strengthened with the decrease of both the area ratio and the Tafel constants. These results provide valuable information to the researchers who investigate steel corrosion.

  12. Fatigue Performance of Fiber Reinforced Concrete

    DEFF Research Database (Denmark)

    Jun, Zhang; Stang, Henrik

    1996-01-01

    The objective of the present study is to obtain basic data of fibre reinforced concrete under fatigue load and to set up a theoretical model based on micromechanics. In this study, the bridging stress in fiber reinforced concrete under cyclic tensile load was investigted in details. The damage...... mechanism of the interface between fiber and matrix was proposed and a rational model given. Finally, the response of a steel fiber reinforced concrete beam under fatigue loading was predicted based on this model and compared with experimental results....

  13. FRP Composites Strengthening of Concrete Columns under Various Loading Conditions

    Directory of Open Access Journals (Sweden)

    Azadeh Parvin

    2014-04-01

    Full Text Available This paper provides a review of some of the progress in the area of fiber reinforced polymers (FRP-strengthening of columns for several loading scenarios including impact load. The addition of FRP materials to upgrade deficiencies or to strengthen structural components can save lives by preventing collapse, reduce the damage to infrastructure, and the need for their costly replacement. The retrofit with FRP materials with desirable properties provides an excellent replacement for traditional materials, such as steel jacket, to strengthen the reinforced concrete structural members. Existing studies have shown that the use of FRP materials restore or improve the column original design strength for possible axial, shear, or flexure and in some cases allow the structure to carry more load than it was designed for. The paper further concludes that there is a need for additional research for the columns under impact loading senarios. The compiled information prepares the ground work for further evaluation of FRP-strengthening of columns that are deficient in design or are in serious need for repair due to additional load or deterioration.

  14. Applications and Properties of Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Amit Rai1 ,

    2014-05-01

    Full Text Available In conventional concrete, micro-cracks develop before structure is loaded because of drying shrinkage and other causes of volume change. When the structure is loaded, the micro cracks open up and propagate because of development of such micro-cracks, results in inelastic deformation in concrete. Fibre reinforced concrete (FRC is cementing concrete reinforced mixture with more or less randomly distributed small fibres. In the FRC, a numbers of small fibres are dispersed and distributed randomly in the concrete at the time of mixing, and thus improve concrete properties in all directions. The fibers help to transfer load to the internal micro cracks. FRC is cement based composite material that has been developed in recent years. It has been successfully used in construction with its excellent flexural-tensile strength, resistance to spitting, impact resistance and excellent permeability and frost resistance. It is an effective way to increase toughness, shock resistance and resistance to plastic shrinkage cracking of the mortar. These fibers have many benefits. Steel fibers can improve the structural strength to reduce in the heavy steel reinforcement requirement. Freeze thaw resistance of the concrete is improved. Durability of the concrete is improved to reduce in the crack widths. Polypropylene and Nylon fibers are used to improve the impact resistance. Many developments have been made in the fiber reinforced concrete.

  15. Durability of cracked fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1998-01-01

    Durability studies are carried out at BKM as part of the research project "Design Methods for Fibre Reinforced Concrete" (FRC) involving BKM, The Concrete Research Center at DTI, Building Technology at Aalborg University, Rambøll, 4K-Beton and Rasmussen & Schiøtz. Concrete beams with or without...... structure are made on specimens drilled or sawed from beams after unloading (mechanical load). The pore structure of the concretes will be studied by microscopy, sorption and suction curves. The test programme involves three different concrete qualities (water-cement ratios). Both steel fibres (ZP...

  16. Design Methods for Fibre Reinforced Concrete

    DEFF Research Database (Denmark)

    Stang, Henrik

    1996-01-01

    The present paper describes the outline of a research project on Fibre Reinforced Concrete (FRC) currently being carried out in Denmark under the supervision of Danish Council of Technology, Danish Technical Research Council and Danish Natural Science Research Counsil....

  17. Fiber-reinforced polymer concrete: Property improvement by gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Martinez B, G. [Laboratorio de Investigacion y Desarrollo de Materiales Avanzados, Facultad de Quimica, Universidad Autonoma del Estado de Mexico, Km. 12 Carretera Toluca-Atlacomulco, San Cayetano 50200, Estado de Mexico (Mexico); Brostow, W. [Laboratory of Advanced Polymers and Optimized Materials, Department of Materials Science and Engineering, University of North Texas, Denton TX 76203-5310 (United States)], e-mail: gonzomartinez02@yahoo.com.mx

    2009-07-01

    Polymer concrete (PC) is a particulate composite in which a thermoset resin forms a polymeric matrix and binds inorganic aggregates (dispersed particles of strengthening phases). This in contrast to Portland cement concrete (PCC) in which the binding is a result of interaction of cement with water. Adding polymeric materials to the concrete one can obtain high compressive and flexural strength, high impact and abrasion resistance, lower weight and lower costs. Moreover, PC is a very good repair material for structure elements damaged by trapping water inside the structure and by acid attacks which take place in the PCC. In the present chapter we discuss uses of polymer concrete and the importance of using gamma radiation as a novel technology for manufacturing fiber-reinforced polymer concrete. Our technology is different from the costly and time consuming current procedures such as chemical attack or thermal treatment. (Author)

  18. Ductility Performance of Hybrid Fibre Reinforced Concrete

    OpenAIRE

    S. Eswari; P.N. Raghunath; Suguna, K

    2008-01-01

    This study presents a study on the ductility performance of hybrid fibre reinforced concrete. The influence of fibre content on the ductility performance of hybrid fibre reinforced concrete specimens having different fibre volume fractions was investigated. The parameters of investigation included modulus of rupture, ultimate load, service load, ultimate and service load deflection, crack width, energy ductility and deflection ductility. A total of 27 specimens, 100×100×500 mm, were tested to...

  19. Shaking Table Tests of Reinforced Concrete Frames

    DEFF Research Database (Denmark)

    Skjærbæk, P. S.; Kirkegaard, Poul Henning; Nielsen, Søren R.K.

    -varying systems and to verify various methods for damage assessment of reinforced concrete structures from soft motion measurements. In this study the maximum softening concept will be evaluated. In the paper the assessment obtained by this method is compared to visual damage assessment. The structures considered...... vector ARMA model is suitable for modal identification of degrading reinforced concrete structures and the maximum softening damage index calculated from the obtained identification provides a valuable tool for assessment of the damage state of the structure....

  20. Self-compacting fibre-reinforced concrete

    NARCIS (Netherlands)

    Grunewald, S.; Walraven, J.C.

    2001-01-01

    The project 'self-compacting fibre-reinforced concrete (SCFRC)' is part of the Dutch STW/PPM program - 'cement-bonded materials' - DCT.4010. Subproject III to which the project ,SCFRC' belongs deals with the development of new high performance concretes. The project 'SCFRC' aims at investigating the

  1. Strength of Cracked Reinforced Concrete Disks

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1999-01-01

    The paper deals with models, based on the theory of plasticity, to be used in strength assessments of reinforced concrete disks suffering from different kinds of cracking. Based on the assumption that the sliding strength of concrete is reduced in sections where cracks are located, solutions...

  2. Influence of Additives on Reinforced Concrete Durability

    OpenAIRE

    2014-01-01

    The article presents the results of the research on carbonation and chloride induced corrosion mechanisms in reinforced concrete structures, based on three commercially available concrete admixtures: Xypex Admix C-1000, Penetron Admix and Elkem Microsilica. Carbonation takes place due to carbon dioxide diffusion, which in the required amount is present in the air. Chlorides penetrate concrete in case of the use of deicing salt or structure exploitation in marine atmosphere. Based on the imple...

  3. 预应力与非预应力AFRP加固腐蚀钢筋混凝土梁疲劳性能研究%Experimental study on fatigue performance corroded reinforced concrete beams strengthened with prestressed AFRP sheets

    Institute of Scientific and Technical Information of China (English)

    邓宗才; 李凯

    2009-01-01

    to estimate an equivalent fatigue notch factor for the main reinforcement bars of the tested specimens. Pitting corrosion resulted in an increase in the fatigue notch factor, which in turn resulted in a significant reduction of fatigue life. Based on the experimental results of moderate corroded concrete beams strengthened with AFRP sheets, the fatigue equation was obtained, and this equation can be used in strengthened design for damaged bridge.

  4. Modelling the Loss of Steel-Concrete Bonds in Corroded Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    2007-01-01

    The existing stochastic models for deterioration of reinforced concrete structures is extended by adding modelling of "loss of bond" due to corrosion between the reinforcement bars and the surrounding concrete.......The existing stochastic models for deterioration of reinforced concrete structures is extended by adding modelling of "loss of bond" due to corrosion between the reinforcement bars and the surrounding concrete....

  5. Modeling of crack propagation in strengthened concrete disks

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Stang, Henrik

    2013-01-01

    Crack propagation in strengthened concrete disks is a problem that has not yet been addressed properly. To investigate it, a cracked half-infinite disk of concrete is strengthened with a linear elastic material bonded to the surface, and analyzed using two different finite element modeling approa...

  6. Limit analysis of solid reinforced concrete structures

    DEFF Research Database (Denmark)

    Larsen, Kasper Paaske

    2009-01-01

    element for lower bound analysis of reinforced concrete structures is presented. The method defines the stress state at a point within the solid as a combination of concrete- and reinforcement stresses and yield criterions are applied to the stress components separately. This method allows for orthotropic......Recent studies have shown that Semidefinite Programming (SDP) can be used effectively for limit analysis of isotropic cohesive-frictional continuums using the classical Mohr-Coulomb yield criterion. In this paper we expand on this previous research by adding reinforcement to the model and a solid...... reinforcement and it is therefore possible to analyze structures with complex reinforcement layouts. Tests are conducted to validate the method against well-known analytical solutions....

  7. A state of the art review on reinforced concrete beams with openings retrofitted with FRP

    Science.gov (United States)

    Osman, Bashir H.; Wu, Erjun; Ji, Bohai; S Abdelgader, Abdeldime M.

    2016-09-01

    The use of externally bonded fiber reinforced polymer (FRP) sheets, strips or steel plates is a modern and convenient way for strengthening of reinforced concrete (RC) beams. Several researches have been carried out on reinforced concrete beams with web openings that strengthened using fiber reinforced polymer composite. Majority of researches focused on shear strengthening compared with flexural strengthening, while others studied the effect of openings on shear and flexural separately with various loading. This paper investigates the impact of more than sixty articles on opening reinforced concrete beams with and without strengthening by fiber reinforcement polymers FRP. Moreover, important practical issues, which are contributed in shear strengthening of beams with different strengthening techniques, such as steel plate and FRP laminate, and detailed with various design approaches are discussed. Furthermore, a simple technique of applying fiber reinforced polymer contributed with steel plate for strengthening the RC beams with openings under different load application is concluded. Directions for future research based on the existing gaps of the present works are presented.

  8. Flexural retrofitting of reinforced concrete structures using Green Natural Fiber Reinforced Polymer plates

    Science.gov (United States)

    Cervantes, Ignacio

    An experimental study will be carried out to determine the suitability of Green Natural Fiber Reinforced Polymer plates (GNFRP) manufactured with hemp fibers, with the purpose of using them as structural materials for the flexural strengthening of reinforced concrete (RC) beams. Four identical RC beams, 96 inches long, are tested for the investigation, three control beams and one test beam. The first three beams are used as references; one unreinforced, one with one layer of Carbon Fiber Reinforced Polymer (CFRP), one with two layers of CFRP, and one with n layers of the proposed, environmental-friendly, GNFRP plates. The goal is to determine the number of GNFRP layers needed to match the strength reached with one layer of CFRP and once matched, assess if the system is less expensive than CFRP strengthening, if this is the case, this strengthening system could be an alternative to the currently used, expensive CFRP systems.

  9. Design procedures for the use of composites in strengthening of reinforced concrete structures state-of-the-art report of the RILEM Technical Committee 234-DUC

    CERN Document Server

    Sena-Cruz, José

    2016-01-01

    This book analyses the current knowledge on structural behaviour of RC elements and structures strengthened with composite materials (experimental, analytical and numerical approaches for EBR and NSM), particularly in relation to the above topics, and the comparison of the predictions of the current available codes/recommendations/guidelines with selected experimental results. The book shows possible critical issues (discrepancies, lacunae, relevant parameters, test procedures, etc.) related to current code predictions or to evaluate their reliability, in order to develop more uniform methods and basic rules for design and control of FRP strengthened RC structures. General problems/critical issues are clarified on the basis of the actual experiences, detect discrepancies in existing codes, lacunae in knowledge and, concerning these identified subjects, provide proposals for improvements. The book will help to contribute to promote and consolidate a more qualified and conscious approach towards rehabilitation...

  10. Behavior of Concrete Cylinders Strengthened with a Basalt-FRP and Subjected to Mechanical Loads and Elevated Temperatures

    Science.gov (United States)

    Tulendinov, T.; Zesers, A.; Tamužs, V.

    2017-09-01

    Concrete samples were manufactured and strengthened with a basalt FRP (BFRP) using two kinds of winding patterns (spiral and tight). The efficiency of common and temperature-resistant epoxy binders were studied. Some of the samples were encased in an external concrete shell for an additional protection of the FRP reinforcement during heating. Both plain and polypropylene-microfiber-reinforced concretes were used for the external casing. Stress-strain relations of the samples before and after heating were obtained. The effects of high temperatures on the integrity of concrete samples with a BFRP reinforcement was investigated.

  11. Estudio Experimental de Piezas Lineales de Hormigón Reforzadas con Fibras de Carbono Experimental Study of Reinforced Concrete Beams Strengthened with Carbon Fibers

    Directory of Open Access Journals (Sweden)

    M. Valcuende

    2004-01-01

    Full Text Available Se ha estudiado el comportamiento de seis vigas reforzadas simultáneamente con láminas y tejidos de fibra de carbono. Se analiza, para este tipo de refuerzos, la validez de dos de los métodos de cálculo posiblemente más utilizados. En ambos métodos se plantean las ecuaciones de equilibrio de fuerzas y momentos, pero se introducen suposiciones diferentes: i el acero tiene suficiente capacidad plástica para no romperse y ii el agotamiento se produce siempre por rotura de la lámina. Los resultados obtenidos ponen de manifiesto que refuerzos de láminas y tejidos de fibra de carbono influyen notablemente sobre las piezas, mejorando su capacidad portante y modificando su comportamiento estructural en cuanto a rigidez y ductilidadA study on the behaviour of six beams reinforced with carbon fiber laminates and fabrics was done. The validity of the two most commonly used methods of evaluating the effects of these reinforcements was analyzed. Both methods propose equilibrium equations based on forces and moments, although introducing two different suppositions: i that the steel posesses enough elasticity to avoid breakage, and ii failure is always produced by the breakage of the laminate. The results obtained demonstrate that carbon fiber laminates and fabric reinforcements have notable influence on the pieces, improving their loading capacities and modifying their structural behavior regarding stiffness and ductility

  12. Modelling Tension Stiffening in Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Christiansen, Morten Bo; Nielsen, Mogens Peter

    1997-01-01

    flexure.In the first model, the yield zone model, it is assumed that the mean crack distance is a descending function of the reinforcement stress in a crack. Furthermore it is assumed that in certain zones between the cracks the concrete is carrying its full effective tensile strength, i.e. the concrete...... with deformations in reinforced concrete disks subjected to pure shear.A physical model for the shear stress-shear strain behaviour of disks, including tension stiffening, is proposed.In the disk model it is assumed that the tensile principal stress in the concrete decreases linearly from the initiation of cracking...... until a certain load level. At any load level the model can predict the shear strains of the disk and the inclination of the crack system. When regarding tension stiffening this latter parameter will be a function of the load level.The model is compared with experimental data, and in the light...

  13. FOAM CONCRETE REINFORCEMENT BY BASALT FIBRES

    Directory of Open Access Journals (Sweden)

    Zhukov Aleksey Dmitrievich

    2012-10-01

    Full Text Available The authors demonstrate that the foam concrete performance can be improved by dispersed reinforcement, including methods that involve basalt fibres. They address the results of the foam concrete modeling technology and assess the importance of technology-related parameters. Reinforcement efficiency criteria are also provided in the article. Dispersed reinforcement improves the plasticity of the concrete mix and reduces the settlement crack formation rate. Conventional reinforcement that involves metal laths and rods demonstrates its limited application in the production of concrete used for thermal insulation and structural purposes. Dispersed reinforcement is preferable. This technology contemplates the infusion of fibres into porous mixes. Metal, polymeric, basalt and glass fibres are used as reinforcing components. It has been identified that products reinforced by polypropylene fibres demonstrate substantial abradability and deformability rates even under the influence of minor tensile stresses due to the low adhesion strength of polypropylene in the cement matrix. The objective of the research was to develop the type of polypropylene of D500 grade that would demonstrate the operating properties similar to those of Hebel and Ytong polypropylenes. Dispersed reinforcement was performed by the basalt fibre. This project contemplates an autoclave-free technology to optimize the consumption of electricity. Dispersed reinforcement is aimed at the reduction of the block settlement in the course of hardening at early stages of their operation, the improvement of their strength and other operating properties. Reduction in the humidity rate of the mix is based on the plasticizing properties of fibres, as well as the application of the dry mineralization method. Selection of optimal parameters of the process-related technology was performed with the help of G-BAT-2011 Software, developed at Moscow State University of Civil Engineering. The authors also

  14. Retrofitting Of Reinforced Concrete Column by Steel Jacketing

    Directory of Open Access Journals (Sweden)

    Abhishek Jodawat

    2016-07-01

    Full Text Available Reinforced concrete structures often require strengthening to increase their capacity to sustain additional loads, due to change in use that resulted in additional live loads, deterioration of the load carrying elements, design errors, construction problems during erection, aging of structure itself or upgrading to confirm to current code requirements. These situations may require additional concrete elements or the entire concrete structure to be strengthened, repaired or retrofitted. Common methods for strengthening columns include concrete jacketing, fiber reinforced polymer (FRP jacketing and steel jacketing. All these methods have been shown to effectively increase the axial load capacity of columns. The experimental study was carried out on RC column on designed and detailed using IS 456:2000 provisions. The concrete mix design being performed after conducting numerous material test and cube test to validate expected strength as per specified grade of concrete. The trial testing conducted to estimate load at 1st crack and failure load for normal RC column with capturing displacement using dial gauges at regular load increment in UTM. The loading conditions are decided based on failure load to induce cracks in column under 85% loading of the failure one. In all fifteen specimen casted and tested with three samples for failure load estimation, three samples each for plate jacketing & angle battening system and three samples each for plate jacketing & angle battening with column preloaded to 85% of its failure load. The angle batten system proves to be better compared to full plate retrofitting in terms of load carrying capacity and enhancing confinement effect.

  15. Behavior of Partially Restrained Reinforced Concrete Slabs.

    Science.gov (United States)

    1986-09-01

    Takehira, Derecho , and Iqbal [34] followed a similar approach to arrive at recommended design criteria for 1 the Naval Facilities Engineering Command...Datta, T. K., "Ultimate Strength of Reinforced Concrete Slab-Beam Systems: A New Approach," r Indian Concrete Journal, Bombay, India , Vol. 47, 1973, pp...Journal of Solids and Structures, Vol. 1, 1965, pp. 97-111. 34. Takehira, T., Derecho , A.T., and Iqbal, M., "Design Criteria for Deflection Capacity

  16. 碳纤维布约束下钢纤维混凝土与腐蚀钢筋黏结性能的试验研究%Bond behavior of corroded reinforcement in steel fibrous concrete strengthened with CFRP

    Institute of Scientific and Technical Information of China (English)

    邓宗才; 万操

    2012-01-01

    A total of 96 test specimens with embedded reinforcing bars were strengthened by two layer of transverse CFRP (carbon fiber sheets) after accelerated corrosion. Pullout tests on the specimens were conducted to study the effect of CFRP confinement on the bond behavior between corroded reinforcement and steel fibrous concrete, considering the contributions of different elements, including reinforcing bar types, cover depths, corrosion rates, CFRP confinements, and steel fiber. The failure mechanisms were studied. The test results show that CFRP confinements can make the failure mode of deformed reinforcing bar specimens change from steel fibrous concrete splitting to bar pull-out. The main influencing factors of the ultimate bond strength are reinforcement bar types and cover depths, the ultimate bond strength of deformed reinforcement bar specimens is twice as large as that of plain reinforcement bar specimens, and the ultimate bond strength increases when the cover depth changes from 40mm to 60mm. CFRP is effective on slowing down the bond stress reduction rate and maintaining the bond strength. When the corrosion rate is less than 5% , the ultimate bond strength of corroded steel fibrous concrete specimens increases gradually along with the rise of corrosion rate, and decreases when the corrosion rate is higher than 5 %. The steel fiber can increase the bond strength of reinforcement and steel fibrous concrete effectively, and make the descending branch of bond-slip curves much smoother.%为研究碳纤维布加固对腐蚀钢筋与钢纤维混凝土黏结性能的效用,采用外加电流法对96个预埋钢筋-钢纤维混凝土试件进行加速腐蚀,腐蚀完成后横向包裹两层单向碳纤维布;通过拉拔试验研究纤维布约束对腐蚀钢筋与钢纤维混凝土黏结性能的影响规律,并与普通混凝土试验结果进行对比分析,探讨钢筋种类、保护层厚度、腐蚀率、纤维布约束及钢纤维等对

  17. Influence of Additives on Reinforced Concrete Durability

    Directory of Open Access Journals (Sweden)

    Neverkovica Darja

    2014-12-01

    Full Text Available The article presents the results of the research on carbonation and chloride induced corrosion mechanisms in reinforced concrete structures, based on three commercially available concrete admixtures: Xypex Admix C-1000, Penetron Admix and Elkem Microsilica. Carbonation takes place due to carbon dioxide diffusion, which in the required amount is present in the air. Chlorides penetrate concrete in case of the use of deicing salt or structure exploitation in marine atmosphere. Based on the implemented research, Elkem Microsilica is the recommended additive for the use in aggressive environmental conditions. Use of Xypex Admix C-1000 and Penetron Admix have only average resistance to the aggressive environmental impact.

  18. Frost resistance of fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1999-01-01

    Frost resistance of fibre reinforced concrete with 2.5-4.2% air and 6-9% air (% by volume in fresh concrete) casted in the laboratory and in-situ is compared. Steel fibres with hooked ends (ZP, length 30 mm) and polypropylene fibres (PP, CS, length 12 mm) are applied. It is shown that· addition...... of 0.4-1% by volume of fibres cannot replace air entrainment in order to secure a frost resistant concrete; the minimum amount of air needed to make the concrete frost resistant is not changed when adding fibres· the amount of air entrainment must be increased when fibres are added to establish...... the same amount of air pores as in the corresponding concrete without fibres...

  19. Process of cracking in reinforced concrete beams (simulation and experiment

    Directory of Open Access Journals (Sweden)

    I. N. Shardakov

    2016-10-01

    Full Text Available The paper presents the results of experimental and theoretical investigations of the mechanisms of crack formation in reinforced concrete beams subjected to quasi-static bending. The boundary-value problem has been formulated in the framework of brittle fracture mechanics and solved using the finite-element method. Numerical simulation of the vibrations of an uncracked beam and a beam with cracks of different size serves to determine the pattern of changes in the spectrum of eigenfrequencies observed during crack evolution. A series of sequential quasi-static 4-point bend tests leading to the formation of cracks in a reinforced concrete beam were performed. At each loading step, the beam was subjected to an impulse load to induce vibrations. Two stages of cracking were detected. During the first stage the nonconservative process of deformation begins to develope, but has not visible signs. The second stage is an active cracking, which is marked by a sharp change in eingenfrequencies. The boundary of a transition from one stage to another is well registered. The vibration behavior was examined for the ordinary concrete beams and the beams strengthened with a carbon-fiber polymer. The obtained results show that the vibrodiagnostic approach is an effective tool for monitoring crack formation and assessing the quality of measures aimed at strengthening concrete structures

  20. Ultra thin continuously reinforced concrete pavement research in south Africa

    CSIR Research Space (South Africa)

    Perrie, BD

    2007-08-01

    Full Text Available Ultra thin continuously reinforced concrete pavements (UTCRCP), in literature also referred to as Ultra Thin Reinforced High Performance Concrete (UTHRHPC), have been used in Europe successfully as a rehabilitation measure on steel bridge decks...

  1. 配筋率影响钢筋混凝土悬臂梁碳纤维抗弯加固效果的有限元分析%Finite-element Analysis of Effect of Reinforcement Ratio on Bending Capacity of Reinforced Concrete Cantilever Beams Strengthened with CFRP

    Institute of Scientific and Technical Information of China (English)

    陈悦; 毛毳; 张前进

    2011-01-01

    Firstly, 7 reinforced concrete cantilever beams strengthened with carbon fiber cloth (Group Ⅰ ) are simulated by the ANSYS fi.nite element software. And then the fracture form, raising rate of the bending capacity and the utilization rate of steel reinforcement of the components of these beams in broken condition are analyzed. The results demonstrate that the reinforcement effect is closely bound up with the utilization rate of steel reinforcement. On the basis above, the diameter of longitudinal tensile reinforcement is changed by reducing the steel reinforcement ratio of the beams in Group Ⅰ, and another 7 reinforced concrete cantilever beams (Group Ⅱ) are established. The analysis results indicate that the more adequate the steel reinforcement utilization rate is, the more significantly the bending capacity of the bending component with small longitudinal reinforcement ratio will be improved, and the more prominent economic benefit will be obtained.%利用ANSYS有限元分析软件,对7根碳纤维布加固的钢筋混凝土悬臂梁(第Ⅰ组)进行有限元模拟,对加固后的构件破坏的形态、抗弯承栽力提高幅度以及构件破坏时钢筋的利用率进行了分析.分析发现,构件纵向受拉钢筋的利用率与加固效果密切相关.在此基础上,通过减小第1组构件纵向受拉钢筋的截面尺寸改变配筋率,重新建立了7根钢筋混凝土悬臂梁(第Ⅱ组).分析表明,纵向配筋率较小,受拉钢筋利用越充分的受弯构件,其抗弯承载力提高幅度越明显,经济价值更为突出.

  2. Fracture Toughness of Fiber Reinforced Concrete.

    Science.gov (United States)

    1983-06-01

    14, 1979, pp. 443-449. 5 Mindess , S., Lawrence, F. V., and Kesler, C. E., "The J-Integral as a Fracture Criterion for Fiber Reinforced Concrete...34 Cement and Con- crete Research, Vol. 7, 1977 , pp. 731-742. 6 Velazco, G., Visalvanich, K., and Shah, S. P., "Fracture Behavior and Analysis of Fiber

  3. Rotational Capacity of Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Ulfkjær, J. P.; Henriksen, M. S.; Brincker, Rune

    1995-01-01

    The European Structural Integrity Society-Technical Committee 9, has initiated a Round Robin on 'Scale Effects and Transitional Failure Phenomena of Reinforced Concrete Beams in Flexure'. In Denmark, Aalborg University is participating. The programme for Aalborg University involves an experimental...

  4. Corrosion and Cracking of Reinforced Concrete

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    Modelling of the deterioration of reinforced concrete has in recent years changed from being a deterministic modelling based on experience to be stochastic modelling based on sound and consistent physical, chemical and mechanical principles. In this paper is presented a brief review of modern mod...... for time to initial corrosion, time to initial cracking, and time to a given crack width may be obtained....

  5. Highly Deformable Energy-Dissipating Reinforced Concrete Elements in Seismic Design of Reinforced Concrete Structures

    Directory of Open Access Journals (Sweden)

    Momoh Emmanuel Owoichoechi

    2017-06-01

    Full Text Available Incorporating scrap tyre rubber particles as partial replacement for aggregates has been found to produce concrete with improved ductility, deformability and damping which are desired characteristics of a viable material for enhancing structural response to earthquake vibrations. An analytical study using Drain-2dX was carried out to investigate the response of 4-storey, 3-bay reinforced concrete frames on innovative rubberised concrete deformable foundation models to simulated earthquake scaled to 5 different peak ground accelerations. Stress-strain properties of 3-layers aramid fibre-reinforced polymer (FRP-confinement for concrete incorporating waste rubber from scrap vehicle tyres were used to model the elements of this foundation models. With a partial decoupling of the superstructure from the direct earthquake force, the models showed up to 70% reduction in base shear, an improved overall q-factor of 7.1, and an estimated frame acceleration of 0.11g for an earthquake peak ground acceleration of 0.44g. This implies that a non-seismically designed reinforced concrete frame on the proposed rubberised concrete deformable foundation system would provide a simple, affordable and equally efficient alternative to the conventional and usually expensive earthquake resistant concrete frames. A supplementary Arrest System (SAS was proposed to anchor the frame from the resulting soft storey at the rubberised concrete foundation. A further research is recommended for the design of concrete hinges with rubberised concrete as used in the model with the most impressive response.

  6. Shear Behavior of Concrete Beams Reinforced with GFRP Shear Reinforcement

    OpenAIRE

    Heecheul Kim; Min Sook Kim; Myung Joon Ko; Young Hak Lee

    2015-01-01

    This paper presents the shear capacities of concrete beams reinforced with glass fiber reinforced polymer (GFRP) plates as shear reinforcement. To examine the shear performance, we manufactured and tested a total of eight specimens. Test variables included the GFRP strip-width-to-spacing ratio and type of opening array. The specimen with a GFRP plate with a 3×2 opening array showed the highest shear strength. From the test results, the shear strength increased as the strip-width-to-strip-spac...

  7. What Happens with Reinforced Concrete Structures when the Reinforcement Corrodes

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    In this paper, corrosion of reinforced concrete structures is discussed from the point of view of corrosion products. The different types of corrosion products are presented and a detailed study of the important diffusion coefficient is performed. Stochastic modelling of corrosion initiated...

  8. 喷射FRP加固震损钢筋混凝土柱抗震性能试验%Test of seismic performance of earthquake damaged reinforced concrete columns strengthened with sprayed FRP

    Institute of Scientific and Technical Information of China (English)

    谷倩; 董格; GETAHUNE Bitewlgn Mekonnen; 王翔

    2016-01-01

    Based on the tensile strength tests of 12 groups of 72 pieces of sprayed fiber reinforced polymer (FRP) specimens,the effects of factors such as fiber type,resin matrix material,fibers volume fraction,hybrid ratio of fi-bers and fiber length etc.on the properties such as tensile strength,elastic modulus and elongation at break etc.of sprayed FRP were investigated.The seismic performance of earthquake damaged reinforced concrete (RC)columns specimens strengthened with sprayed basalt fiber reinforced polymer (BFRP)and hybrid basalt-carbon fiber rein-forced polymer (BF-CFRP)was investigated by the quasi-static test of 8 RC columns,and the influences of the thickness of sprayed FRP layer,hybrid ratio of fibers,pre-damage degree of columns and the axial compression ratio of column etc.on the ultimate load capacity,lateral deformation resistance,degradation characteristics of stiffness and hysteresis properties of the strengthened specimens were analyzed.The test results show that the cooperative working performance of glass fiber and vinylester matrix is the best,and basalt fiber can be used as a favorable suc-cedaneum of glass fiber because of its excellent performance of high durability,good ductility and good cooperative working performance with vinylester matrix;hybrid basalt fibers with small amount of carbon fibers used as rein-forcement for resin matrix can effectively increase the tensile strength and deformation performance of sprayed FRP;earthquake damaged RC column can almost be rehabilitated to its designed ultimate load capacity before the earth-quake damage by strengthening with sprayed FRP,and both the ductility and the ability of energy dissipation can be effectively enhanced.This strengthening technique can fast strengthen the earthquake damaged RC column in seis-mic area and effectively hinder the collapse of whole structures exposed to the aftershock and other heavy damages.%通过12组72件喷射纤维/树脂复合材料(FRP)试样的拉伸强度

  9. Frost resistance of fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1999-01-01

    of 0.4-1% by volume of fibres cannot replace air entrainment in order to secure a frost resistant concrete; the minimum amount of air needed to make the concrete frost resistant is not changed when adding fibres· the amount of air entrainment must be increased when fibres are added to establish......Frost resistance of fibre reinforced concrete with 2.5-4.2% air and 6-9% air (% by volume in fresh concrete) casted in the laboratory and in-situ is compared. Steel fibres with hooked ends (ZP, length 30 mm) and polypropylene fibres (PP, CS, length 12 mm) are applied. It is shown that· addition...

  10. Towards Rational Design Method for Strengthening of Concrete Structures by External Bonding

    Directory of Open Access Journals (Sweden)

    Furuuchi H.

    2012-01-01

    Full Text Available Many infrastructures need to be repaired or strengthened due to various reasons, such as unexpected deterioration and changes in performance requirement. This paper presents the following recent achievements by the authors’ group on design method for flexural strengthening of concrete structures by external bonding; (i fracture characteristics of interface between substrate concrete and cementitious overlay, (ii crack spacing of flexural strengthened beams, which affects debonding strength, (iii strengths of intermediate crack (IC debonding and end peeling, (iv strength of concrete cover separation, and (v effectiveness of strengthening by external bonding. A unified approach for flexural strengthening by steel plate, fiber reinforced polymer lami¬nate and cementitious overlay, for both intermediate crack (IC debonding, including end peeling, and concrete cover separation is pre¬sented with consideration of crack spacing in the streng¬thened members. Appropriate interfacial rough¬¬¬ness to achieve efficient interface bond property is clari¬fied and the concept of effectiveness of strengthen¬ing is proposed for better strengthening design.

  11. Ductility Performance of Hybrid Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    S. Eswari

    2008-01-01

    Full Text Available This study presents a study on the ductility performance of hybrid fibre reinforced concrete. The influence of fibre content on the ductility performance of hybrid fibre reinforced concrete specimens having different fibre volume fractions was investigated. The parameters of investigation included modulus of rupture, ultimate load, service load, ultimate and service load deflection, crack width, energy ductility and deflection ductility. A total of 27 specimens, 100×100×500 mm, were tested to study the above parameters. The specimens incorporated 0.0 to 2.0% volume fraction of polyolefin and steel fibres in different proportions. The ductility performance of hybrid fibre reinforced concrete specimens was compared with that of plain concrete. The test results show that addition of 2.0% by volume of hybrid fibres improves the ductility performance appreciably. An adaptive Neuro-Fuzzy based model has been proposed to predict the ductility performance characteristics. A reasonably close agreement has been obtained between the experimental and predicted results.

  12. Random Time Dependent Resistance Analysis on Reinforced Concrete Structures

    Institute of Scientific and Technical Information of China (English)

    GUAN Chang-sheng; WU Ling

    2002-01-01

    The analysis method on random time dependence of reinforced concrete material is introduced,the effect mechanism on reinforced concrete are discussed, and the random time dependence resistance of reinforced concrete is studied. Furthermore, the corrosion of steel bar in reinforced concrete structures is analyzed. A practical statistical method of evaluating the random time dependent resistance, which includes material, structural size and calculation influence, is also established. In addition, an example of predicting random time dependent resistance of reinforced concrete structural element is given.

  13. Flat slabs strengthened to punching with carbon fiber reinforced polymer (CFRP dowels

    Directory of Open Access Journals (Sweden)

    Helder Luiz da Silva Rodrigues

    2015-10-01

    Full Text Available This paper presents results of punching tests carried out in four reinforced concrete flat slabs, one of them without shear reinforcement and others strengthened with CFRP dowels. Slabs were 1000 mm square meters and 60 mm thick and were subjected to mid span loadings until failure. The strengthening arrangements were radial and cruciform, varying the number of layers of CFRP dowels. The results presented include vertical displacements, strain on steel and concrete, ultimate loads and failure mode, as well as estimation of resistance based on the Brazilian standards. It was observed significant improvement on punching resistance of the strengthened slabs when compared to the reference slab, highlighting the good performance for the strengthening system evaluated.

  14. FLEXURAL TOUGHNESS OF STEEL FIBER REINFORCED CONCRETE

    Directory of Open Access Journals (Sweden)

    Fehmi ÇİVİCİ

    2006-02-01

    Full Text Available Fiber concrete is a composite material which has mechanical and physical characteristics unlike plain concrete. One of the important mechanical characteristics of fiber concrete is its energy absorbing capability. This characteristics which is also called toughness, is defined as the total area under the load-deflection curve. A number of composite characteristics such as crack resistance, ductility and impact resistance are related to the energy absorbtion capacity. According to ASTM C 1018 and JSCE SF-4 the calculation of toughness is determined by uniaxial flexural testing. Fiber concrete is often used in plates such as bridge decks, airport pavements, parking areas, subjected to cavitation and erosion. In this paper, toughness has been determined according to ASTM C 1018 and JSCE SF-4 methods by testing beam specimens. Energy absorbing capacities of plain and steel fiber reinforced concrete has been compared by evaluating the results of two methods. Also plain and steel fiber reinforced plate specimens behaviors subjected to biaxial flexure are compared by the loaddeflection curves of each specimen.

  15. Strength of Cracked Reinforced Concrete Disks

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1999-01-01

    The paper deals with models, based on the theory of plasticity, to be used in strength assessments of reinforced concrete disks suffering from different kinds of cracking. Based on the assumption that the sliding strength of concrete is reduced in sections where cracks are located, solutions...... for the shear strength of disks with initial cracks and disks suffering from isotropic cracking are presented. Furthermore, in the case of isotropicly cracked disks subjected to arbitrary in-plane loading, a general yield condition is derived....

  16. Tensile behavior and tension stiffening of reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Choun, Young Sun; Seo, Jeong Moon

    2001-03-01

    For the ultimate behavior analysis of containment buildings under severe accident conditions, a clear understanding of tensile behaviors of plain and reinforced concrete is necessary. Nonlinear models for tensile behaviors of concrete are also needed. This report describe following items: tensile behaviors of plain concrete, test results of reinforced concrete panels in uniaxial and biaxial tension, tension stiffening. The tensile behaviors of reinforced concrete are significantly influenced by the properties of concrete and reinforcing steel. Thus, for a more reliable evaluation of tensile behavior and ultimate pressure capacity of a reinforced or prestressed concrete containment building, an advanced concrete model which can be considered rebar-concrete interaction effects should be developed. In additions, a crack behavior analysis method and tension stiffening models, which are based on fracture mechanics, should be developed. The model should be based on the various test data from specimens considering material and sectional properties of the containment building.

  17. Shear Behavior of Concrete Beams Reinforced with GFRP Shear Reinforcement

    Directory of Open Access Journals (Sweden)

    Heecheul Kim

    2015-01-01

    Full Text Available This paper presents the shear capacities of concrete beams reinforced with glass fiber reinforced polymer (GFRP plates as shear reinforcement. To examine the shear performance, we manufactured and tested a total of eight specimens. Test variables included the GFRP strip-width-to-spacing ratio and type of opening array. The specimen with a GFRP plate with a 3×2 opening array showed the highest shear strength. From the test results, the shear strength increased as the strip-width-to-strip-spacing ratio increased. Also, we used the experimental results to evaluate whether the shear strength equations of ACI 318-14 and ACI 440.1R can be applied to the design of GFRP shear reinforcement. In the results, the ACI 440 equation underestimated the experimental results more than that of ACI 318.

  18. Strength Evaluation of Steel-Nylon Hybrid Fibre Reinforced Concrete

    OpenAIRE

    Maniram Kumar; Er. Ankush Khadwal

    2014-01-01

    When fibres like steel, glass, polypropylene, nylon, carbon, aramid, polyester, jute, etc are mixed with concrete known as fibre reinforced concrete. To overcome the deficiencies of concrete; fibres are added to improve the performance of concrete. In this research hybrid reinforced concrete is made by using steel and nylon 6 fibres. The inclusion of both steel and nylon 6 fibres are used in order to combine the benefits of both fibers; structural improvements provided by stee...

  19. Ductility of Reinforced Concrete Structures in Flexure

    DEFF Research Database (Denmark)

    Hestbech, Lars

    2013-01-01

    In this thesis, a rotational capacity model for flexural reinforced concrete elements is presented. The model is based on the general assumption, that any other failure mode than bending is prevented by proper design. This includes failure due to shear, anchorage, concentrated loads etc. Likewise......, beams governed by failure described by Kani’s Valley are not covered by the presented model. Hence, the model is delimited to shear reinforced elements failing in flexure. The rotational capacity model is divided into the following calculation procedures. 1. A cross sectional analysis of the critical...... are not necessarily so. An example shows the applicability of the model and a parametric study shows the advantages of the model compared with code provisions. Finally, improvements of the compression zone modelling is performed in order to include a better performance when concrete crushing is the failure criterion...

  20. Flexural strength enhancement of confined reinforced concrete columns

    OpenAIRE

    Pam, HJ; Ho, JCM

    2001-01-01

    As part of a continuing research study, this paper proposes a new design aid to calculate the actual moment capacity of confined reinforced concrete columns. Up to now the moment capacity of a reinforced concrete column is calculated based on the code's guidelines for an unconfined section. As most reinforced concrete columns contain transverse or confining reinforcement, which will enhance the column moment capacity, the actual moment capacity will be much higher than the unconfined moment c...

  1. Concrete cover cracking due to uniform reinforcement corrosion

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe; Michel, Alexander; Geiker, Mette Rica;

    2013-01-01

    is calculated using literature data on corrosion rate and Faraday’s law. The parameters varied comprise reinforcement diameter, concrete cover thickness and concrete material properties, viz. concrete tensile strength and ductility (plain concrete and fibre reinforced concrete). Results obtained from......Service life design (SLD) is an important tool for civil engineers to ensure that the structural integrity and functionality of the structure is not compromised within a given time frame, i.e. the service life. In SLD of reinforced concrete structures, reinforcement corrosion is of major concern...... and reinforcement de-passivation is a frequently used limit state. The present paper investigates an alternative limit state: corrosion-induced cover cracking. Results from numerical simulations of concrete cover cracking due to reinforcement corrosion are presented. The potential additional service life...

  2. Performance of Strengthened Non-Uniformly Corroded Reinforced SCC-RAP Members

    Directory of Open Access Journals (Sweden)

    Ahmed Abdel-Mohti

    2016-12-01

    Full Text Available This research examines the performance of strengthened non-uniformly corroded reinforced self-consolidating concrete (SCC members. This paper focuses on three aspects of concrete including corrosion, concrete cover loss, and repair technique. Up to a 50% corrosion level is considered in this study. Corrosion was experimentally induced and was simulated in other cases. Twenty-six reinforced concrete (RC members with various corrosion levels or simulated corrosion levels were constructed and investigated. The beams with corrosion problems including those that had experimentally induced corrosion or simulated corrosion, with or without concrete cover, were repaired using carbon fiber reinforced polymer (CFRP sheets and U-wraps. Two line loads were applied to all of the non-repaired and repaired beams constructed in this study until failure. It was found that it is conservative to model the actual corrosion by simulating the equivalent area of steel reinforcing for up to a 20% level of corrosion. For corrosion levels over 20%, the simulated corrosion over predicts the load capacity of the actual corrosion cases. When the concrete cover was lost and for a corrosion level larger than 10%, the repaired beam did not reach similar performance to that of a repaired beam with a concrete cover that was still intact. It appears that using two layers of CFRP sheet did not improve the load capacity further, but rather improved the ductility of the deteriorated RC member.

  3. Flow modelling of steel fibre reinforced self-compacting concrete

    DEFF Research Database (Denmark)

    Svec, Oldrich

    Concrete is one of the most widely used materials in the world. Ordinary concrete composition makes the material strong in compression yet weak and brittle in tension. Steel reinforced concrete successfully eliminates the weak tensile properties of the ordinary concrete. Steel fibres dispersed...... in concrete can efficiently substitute or supplement conventional steel reinforcement, such as reinforcement bars. Ordinary concrete composition further makes the material stiff and non-flowable. Self-compacting concrete is an alternative material of low yield stress and plastic viscosity that does flow...... and fills the formwork with a little or no effort. Steel fibre reinforced self-compacting concrete is a logical combination of the two types of concrete. The combination nevertheless creates several challenges. It has been observed by many authors that steel fibres orient and distribute according...

  4. Long term behavior of self-compacting reinforced concrete beams

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-jie; YU Zhi-wu; JIANG Li-zhong

    2008-01-01

    Tests were carded out on 8 self-compacting reinforced concrete(SCC) beams and 4 normal reinforced concrete beams. The effects of mode of consolidation, load level, reinforcing ratio and structural type on long term behavior of SCC were investigated. Under the same environmental conditions, the shrinkage-time curve of self-compacting concrete beam is very similar to that of normal concrete beam. For both self-compacting reinforced concrete beams and normal reinforced concrete beams, the rate of shrinkage at early stages is higher, the shrinkage strain at 2 months is about 60% of the maximum value at one year. The shrinkage strain of self-compacting reinforced concrete beam after one year is about 450×10-6. Creep deflection of self-compacting reinforced concrete beam decreases as the tensile reinforcing ratio increases. The deflection creep coefficient of self-compacting reinforced concrete beam after one and a half year is about 1.6, which is very close to that of normal reinforced concrete beams cast with vibration. Extra cautions considering shrinkage and creep behavior are not needed for the use of SCC in engineering practices.

  5. Preparation and characterization of glass fibers - polymers (epoxy) bars (GFRP) reinforced concrete for structural applications

    Science.gov (United States)

    Alkjk, Saeed; Jabra, Rafee; Alkhater, Salem

    2016-06-01

    The paper presents some of the results from a large experimental program undertaken at the Department of Civil Engineering of Damascus University. The project aims to study the ability to reinforce and strengthen the concrete by bars from Epoxy polymer reinforced with glass fibers (GFRP) and compared with reinforce concrete by steel bars in terms of mechanical properties. Five diameters of GFRP bars, and steel bars (4mm, 6mm, 8mm, 10mm, 12mm) tested on tensile strength tests. The test shown that GFRP bars need tensile strength more than steel bars. The concrete beams measuring (15cm wide × 15cm deep × and 70cm long) reinforced by GFRP with 0.5 vol.% ratio, then the concrete beams reinforced by steel with 0.89 vol.% ratio. The concrete beams tested on deflection test. The test shown that beams which reinforced by GFRP has higher deflection resistance, than beams which reinforced by steel. Which give more advantage to reinforced concrete by GFRP.

  6. Preparation and characterization of glass fibers – polymers (epoxy bars (GFRP reinforced concrete for structural applications

    Directory of Open Access Journals (Sweden)

    Alkjk Saeed

    2016-06-01

    Full Text Available The paper presents some of the results from a large experimental program undertaken at the Department of Civil Engineering of Damascus University. The project aims to study the ability to reinforce and strengthen the concrete by bars from Epoxy polymer reinforced with glass fibers (GFRP and compared with reinforce concrete by steel bars in terms of mechanical properties. Five diameters of GFRP bars, and steel bars (4mm, 6mm, 8mm, 10mm, 12mm tested on tensile strength tests. The test shown that GFRP bars need tensile strength more than steel bars. The concrete beams measuring (15cm wide × 15cm deep × and 70cm long reinforced by GFRP with 0.5 vol.% ratio, then the concrete beams reinforced by steel with 0.89 vol.% ratio. The concrete beams tested on deflection test. The test shown that beams which reinforced by GFRP has higher deflection resistance, than beams which reinforced by steel. Which give more advantage to reinforced concrete by GFRP.

  7. Theoretical study for Bond between Reinforcement steel and Concrete

    Directory of Open Access Journals (Sweden)

    usama mostafa mahran

    2013-04-01

    Full Text Available The behavior and load carrying behavior of reinforced concrete structures is influence by the interaction between the concrete and reinforcement. The stress transfer between reinforcement and concrete in the longitudinal direction of the bars is called bond. An essential feature of reinforced concrete is the bond between steel and concrete. Anchorage of reinforcement depends on the bond between steel and concrete, crack width and crack spacing are mainly governed by it. So, stiffness, deformation and dynamic behavior are influenced by it, and in reverse loading damping and energy dissipation is a function of bond. This is one of the reasons why bond has been, and still is, a topic of fundamental and applied research. Bond stress is the equivalent unit shear stress acting in parallel to the reinforcing bar on the interface between reinforcing steel bar and concrete. Due to the transfer of forces through bond stress, between the reinforcing rebar and concrete, the force in the reinforcing bar changes along its length. Because bond stress is thought of as stress per unit area of bar surface, it is related to the rate of change of steel stress. Consequently, to have bond stress it is necessary to have a changing steel stress. In cases of high stress at the contact interface, near cracks or end anchorages, the bond stresses are related to relative displacements between concrete and steel. These relative displacements, which are caused by different average strains in the concrete and the steel, are usually called bond-slip (t-d.

  8. The effect of concrete strength and reinforcement on toughness of reinforced concrete beams

    OpenAIRE

    Carneiro, Joaquim A. O.; Jalali, Said; Teixeira, Vasco M. P.; Tomás, M.

    2005-01-01

    The objective pursued with this work includes the evaluating of the strength and the total energy absorption capacity (toughness) of reinforced concrete beams using different amounts of steel-bar reinforcement. The experimental campaign deals with the evaluation of the threshold load prior collapse, ultimate load and deformation, as well as the beam total energy absorption capacity, using a three point bending test. The beam half span displacement was measured using a displacement transducer,...

  9. Performance of steel-making slag concrete reinforced with fibers

    OpenAIRE

    Ortega-López Vanesa; Fuente-Alonso José Antonio; Skaf Marta; Santamaría Amaia; Aragón Ángel; Manso Juan Manuel

    2017-01-01

    In this research, the possibility of making concrete reinforced with fibers and manufactured with recycled aggregates from carbon steel production was explored. Electric arc furnace slag (EAFS) was used as coarse and medium aggregate, and part of the sand sizes. Metallic and synthetic fibers were added in different amounts. Initially, the properties of EAFS and their suitability to be used in the manufacture fiber reinforced concrete were analysed. Then, a series of fiber reinforced concrete ...

  10. ANALYSIS OF EXPOSURE OF REINFORCED CONCRETE BUILDINGS TO TEMPERATURE LOADS

    OpenAIRE

    2012-01-01

    The co-authors consider the problem of analysis of building structures in respect of combined effects of forces and temperatures. Results of fire tests of reinforced concrete walls and slabs are presented. Overview of the analysis of the fire resistance of reinforced-concrete buildings is also provided. As a result of the research, numerical solutions were obtained in respect of deflections, stresses, deformations and internal forces arising in a reinforced concrete bearing wall and plate...

  11. Durability of GFRP reinforcing bars and their bond in concrete

    OpenAIRE

    Rolland, Arnaud; Chataigner, Sylvain; Quiertant, Marc; Benzarti, Karim; Argoul, Pierre

    2015-01-01

    The use of composite reinforcing bars (rebars) for the reinforcement of concrete appears as an attractive solution to prevent corrosion, which is the main pathology encountered on concrete structures. Although such rebars are being used for more than ten years, there is a clear lack of knowledge regarding their durability, especially under alkaline environment. This paper aims at investigating the evolutions of tensile properties and bond in concrete of GFRP (Glass Fiber Reinforced Polymer...

  12. Reinforced concrete design to Eurocode 2

    CERN Document Server

    Toniolo, Giandomenico

    2017-01-01

    This textbook describes the basic mechanical features of concrete and explains the main resistant mechanisms activated in the reinforced concrete structures and foundations when subjected to centred and eccentric axial force, bending moment, shear, torsion and prestressing,. It presents a complete set of limit-state design criteria of the modern theory of RC incorporating principles and rules of the final version of the official Eurocode 2. This textbook examines methodological more than notional aspects of the presented topics, focusing on the verifications of assumptions, the rigorousness of the analysis and the consequent degree of reliability of results. Each chapter develops an organic topic, which is eventually illustrated by examples in each final paragraph containing the relative numerical applications. These practical end-of-chapter appendices and intuitive flow-charts ensure a smooth learning experience. The book stands as an ideal learning resource for students of structural design and analysis cou...

  13. Reliability of Reinforced Concrete Buildings During Construction

    Institute of Scientific and Technical Information of China (English)

    方东平; 耿川东; 张传敏; 祝宏毅; 刘西拉

    2004-01-01

    The safety analysis of reinforced concrete buildings during construction should be based on the comprehensive understanding of loads, load effects, structural resistance, and available safety index of the structure. This paper analyzes the characteristics and probabilistic models of resistance, loads, and load effects. A method was developed to calculate the probability of failure based on Monte Carlo simulation and models proposed in previous articles. Construction examples were used to analyze the influence of live load on the probability of failure. The results show that when the live load increases, the maximum probability of failure increases with acceleration. The results suggest that the construction live load should be carefully addressed during construction.

  14. Design of Reinforced Concrete Elements Under Fire

    Directory of Open Access Journals (Sweden)

    P. Mihai

    2008-01-01

    Full Text Available Fire safety regulations can have a major impact on many aspects of the overall design of a building, including layout, aesthetics, function, and cost. Rapid developments in modern building technology in the last decades often have resulted in unconventional structures and design solutions. Because the world is developed continuously, the physical size of buildings increases continually; there is a tendency to build large underground car parks, warehouses, and shopping complexes. As a result, we have a worldwide movement to replace prescriptive building codes with ones based on performance. The paper presents the basic principles for the designing process of reinforced concrete elements under fire.

  15. EXPERIMENTAL STUDY OF SEISMIC BEHAVIORS OF CORRODED REINFORCED CONCRETE COLUMNS STRENGTHENED WITH WRAPPED CFRP SHEETS%碳纤维增强材料加固锈蚀钢筋混凝土柱的抗震性能试验研究

    Institute of Scientific and Technical Information of China (English)

    蒋凤昌; 姜晔; 陈红秋; 奚友方; 居平国

    2013-01-01

    钢筋锈蚀以致局部箍筋锈断将会降低混凝土柱的抗震性能,采取碳纤维增强材料( CFRP)加固方法可对此类锈蚀钢筋混凝土柱的抗震性能进行修补。基于28根T形柱的试验研究,初步揭示了钢筋锈蚀率、轴压比、CFRP加固方式和加固层数对混凝土柱抗震性能影响规律。钢筋锈蚀会导致混凝土柱的耗能能力、刚度、承载力和延性不同程度的降低。当钢筋锈蚀率达到15%时,混凝土柱的延性系数下降约40%。经过CFRP加固后,锈蚀柱的滞回环变得较为饱满,耗能能力大大增强,其延性系数可提高约40%,耗能能力可提高约80%。%Due to corrosion or disruption of stirrups in some parts of the coloumn , could seismic behaviors of corroded reinforced concrete columns would cut down , and could be recovered by strengthening with wrapped CFRP sheets . Based on experimental study of 28 T-shaped concrete columns , the laws were revealed that seismic behaviors of concrete columns were affected by rate of reinforcement corrosion , axial compression ratio , strengthening style and layers of wrapped CFRP sheets .Reinforcement corrosion could reduce columns ’ behaviors of energy dissipation , rigidity, capacity and ductility to some degree .The ductility coefficient could be decreased by 40%when the rate of reinforcement corrosion was up to 15%.Strengthened with wrapped CFRP sheets , corroded reinforced concrete columns raised largely their behaviors of energy dissipation , with more full hysteresis loop , and their ductility coefficient could be improved 40%, behaviors of energy dissipation could be raised by 80%.

  16. A Study on Load Carrying Capacity of Fly Ash Based Polymer Concrete Columns Strengthened Using Double Layer GFRP Wrapping

    Directory of Open Access Journals (Sweden)

    S. Nagan

    2014-01-01

    Full Text Available This paper investigates the suitability of glass fiber reinforced polymer (GFRP sheets in strengthening of fly ash based polymer members under compression. Experimental results revealed that load carrying capacity of the confined columns increases with GFRP sheets wrapping. Altogether 18 specimens of M30 and G30 grade short columns were fabricated. The G30 specimens were prepared separately in 8 molarity and 12 molarity of sodium hydroxide concentration. Twelve specimens for low calcium fly ash based reinforced polymer concrete and six specimens of ordinary Portland cement reinforced concrete were cast. Three specimens from each molarity fly ash based reinforced polymer concrete and ordinary Portland cement reinforced concrete were wrapped with double layer of GFRP sheets. The load carrying capacity of fly ash based polymer concrete was tested and compared with control specimens. The results show increase in load carrying capacity and ductility index for all strengthened elements. The maximum increase in load carrying capacity was 68.53% and is observed in strengthened G30 specimens.

  17. ANALYSIS FOR BENDING CAPACITY OF REFORCED CONCRETE BEAMS MULTIPLE STRENGTHENED WITH NEAR-SURFACE MOUNTEDCARBON FIBER REINFORCED PLASTIC BAR AND PRE-STRESSED HELICAL RIB BAR%复合内嵌碳纤维筋预应力螺旋肋钢筋加固混凝土梁承载力分析

    Institute of Scientific and Technical Information of China (English)

    任振华; 曾宪桃; 周丰峻

    2012-01-01

    RC beams can be strengthened with Carbon Fiber Reinforced Plastic (CFRP) and pre-stressed Helical Rib Bar ( HRB) that are inserted into the concrete cover of tensile region in the concrete beams , which can effectively improve force performance of the beams . In order to analyze the failure form, ultimate state and normal section bearing capacity of RC beams composites strengthened with near-surface mounted carbon fiber reinforced plastic bar and pre-stressed helical rib bar , the bearing capacity equation of strengthened beams corresponding to different failure modes was supplied by analyzing force in each stage of beams in pre-stress state, bearing capacity calculating and limit state. In order to inspect and verify the rationality and the reliability of the conclusions and the veracity of the equation, the flexural experimental studies were tested on seven concrete beams strengthened with near-surface mounted carbon fiber reinforced plastic bar and pre-stressed helical rib bar. The results indicate that the failure modes and limit state of strengthened beams are reasonable, the equation can veraciously calculate the bend capacity of strengthened beams.%用碳纤维筋和预应力螺旋肋钢筋共同嵌入到混凝土梁受拉区保护层中对混凝土梁进行加固,能更有效地改善混凝土梁的受力性能.为更有效地分析复合内嵌碳纤维筋预应力螺旋肋钢筋加固混凝土梁的破坏形态、极限状态及正截面承载力,通过对预应力状态下梁各阶段受力情况分析、承载力计算及界限状态的判别,提出了加固混凝土梁对应不同破坏形态下承载力的计算公式.为验证所得分析结论的合理性和可靠性及计算公式的准确性,对7根碳纤维筋预应力螺旋肋钢筋加固的混凝土梁进行弯曲试验,结果表明,被加固梁的破坏形态、极限状态分析是合理的,所提出的计算公式能准确计算加固梁抗弯承载能力.

  18. Rockfall vulnerability assessment for reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    O. Mavrouli

    2010-10-01

    Full Text Available The vulnerability of buildings to the impact of rockfalls is a topic that has recently attracted increasing attention in the scientific literature. The quantification of the vulnerability, when based on empirical or heuristic approaches requires data recorded from historical rockfalls, which are not always available. This is the reason why appropriate alternatives are required. The use of analytical and numerical models can be one of them. In this paper, a methodology is proposed for the analytical evaluation of the vulnerability of reinforced concrete buildings. The vulnerability is included in the risk equation by incorporating the uncertainty of the impact location of the rock block and the subsequent damage level. The output is a weighted vulnerability that ranges from 0 to 1 and expresses the potential damage that a rock block causes to a building in function of its velocity and size. The vulnerability is calculated by the sum of the products of the probability of block impact on each element of the building and its associated damage state, the latter expressed in relative recovery cost terms. The probability of exceeding a specific damage state such as non-structural, local, partial, extensive or total collapse is also important for the quantification of risk and to this purpose, several sets of fragility curves for various rock diameters and increasing velocities have been prepared. An example is shown for the case of a simple reinforced concrete building and impact energies from 0 to 4075 kJ.

  19. Strain Sharing Assessment in Woven Fiber Reinforced Concrete Beams Using Fiber Bragg Grating Sensors.

    Science.gov (United States)

    Montanini, Roberto; Recupero, Antonino; De Domenico, Fabrizio; Freni, Fabrizio

    2016-09-22

    Embedded fiber Bragg grating sensors have been extensively used worldwide for health monitoring of smart structures. In civil engineering, they provide a powerful method for monitoring the performance of composite reinforcements used for concrete structure rehabilitation and retrofitting. This paper discusses the problem of investigating the strain transfer mechanism in composite strengthened concrete beams subjected to three-point bending tests. Fiber Bragg grating sensors were embedded both in the concrete tensioned surface and in the woven fiber reinforcement. It has been shown that, if interface decoupling occurs, strain in the concrete can be up to 3.8 times higher than that developed in the reinforcement. A zero friction slipping model was developed which fitted very well the experimental data.

  20. Monitoring corrosion in reinforced concrete structures

    Science.gov (United States)

    Kung, Peter; Comanici, Maria I.

    2014-06-01

    Many defects can cause deterioration and cracks in concrete; these are results of poor concrete mix, poor workmanship, inadequate design, shrinkage, chemical and environmental attack, physical or mechanical damage, and corrosion of reinforcing steel (RS). We want to develop a suite of sensors and systems that can detect that corrosion is taking place in RS and inform owners how serious the problem is. By understanding the stages of the corrosion process, we can develop special a sensor that detects each transition. First, moisture ingress can be monitored by a fiber optics humidity sensor, then ingress of Chloride, which acts as a catalyst and accelerates the corrosion process by converting iron into ferrous compounds. We need a fiber optics sensor which can quantify Chloride ingress over time. Converting ferric to ferrous causes large volume expansion and cracks. Such pressure build-up can be detected by a fiber optic pressure sensor. Finally, cracks emit acoustic waves, which can be detected by a high frequency sensor made with phase-shifted gratings. This paper will discuss the progress in our development of these special sensors and also our plan for a field test by the end of 2014. We recommend that we deploy these sensors by visually inspecting the affected area and by identifying locations of corrosion; then, work with the designers to identify spots that would compromise the integrity of the structure; finally, drill a small hole in the concrete and insert these sensors. Interrogation can be done at fixed intervals with a portable unit.

  1. RC beams shear-strengthened with fabric-reinforced-cementitious-matrix (FRCM) composite

    Science.gov (United States)

    Loreto, Giovanni; Babaeidarabad, Saman; Leardini, Lorenzo; Nanni, Antonio

    2015-12-01

    The interest in retrofit/rehabilitation of existing concrete structures has increased due to degradation and/or introduction of more stringent design requirements. Among the externally-bonded strengthening systems fiber-reinforced polymers is the most widely known technology. Despite its effectiveness as a material system, the presence of an organic binder has some drawbacks that could be addressed by using in its place a cementitious binder as in fabric-reinforced cementitious matrix (FRCM) systems. The purpose of this paper is to evaluate the behavior of reinforced concrete (RC) beams strengthened in shear with U-wraps made of FRCM. An extensive experimental program was undertaken in order to understand and characterize this composite when used as a strengthening system. The laboratory results demonstrate the technical viability of FRCM for shear strengthening of RC beams. Based on the experimental and analytical results, FRCM increases shear strength but not proportionally to the number of fabric plies installed. On the other hand, FRCM failure modes are related with a high consistency to the amount of external reinforcement applied. Design considerations based on the algorithms proposed by ACI guidelines are also provided.

  2. Shrinkage modeling of concrete reinforced by palm fibres in hot dry environments

    Science.gov (United States)

    Akchiche, Hamida; Kriker, Abdelouahed

    2017-02-01

    The cement materials, such as concrete and conventional mortar present very little resistance to traction and cracking, these hydraulic materials which induces large withdrawals on materials and cracks in structures. The hot dry environments such as: the Saharan regions of Algeria, Indeed, concrete structures in these regions are very fragile, and present high shrinkage. Strengthening of these materials by fibers can provide technical solutions for improving the mechanical performance. The aim of this study is firstly, to reduce the shrinkage of conventional concrete with its reinforcement with date palm fibers. In fact, Algeria has an extraordinary resources in natural fibers (from Palm, Abaca, Hemp) but without valorization in practical areas, especially in building materials. Secondly, to model the shrinkage behavior of concrete was reinforced by date palm fibers. In the literature, several models for still fiber concrete were founded but few are offers for natural fiber concretes. To do so, a still fiber concretes model of YOUNG - CHERN was used. According to the results, a reduction of shrinkage with reinforcement by date palm fibers was showed. A good ability of molding of shrinkage of date palm reinforced concrete with YOUNG - CHERN Modified model was obtained. In fact, a good correlation between experimental data and the model data was recorded.

  3. Subgrade strengthening of roads and railroads as planar geotextile reinforcement

    Directory of Open Access Journals (Sweden)

    Gradkowski Krzysztof

    2016-01-01

    Full Text Available The proper quality of construction of roads and railroads can be achieved by strengthening the of the foundation bed. Measurements and tests the number and order of the layers of geotextile layer of ground indicate the effectiveness of technical solutions involving the reinforcement laid horizontally. The offer technical use of the geotextile reinforcement in the ground layer substrates of roads indicates the possible effectiveness of the strengthening of the subsoil of roads and is also included in this article.

  4. Subgrade strengthening of roads and railroads as planar geotextile reinforcement

    OpenAIRE

    Gradkowski Krzysztof

    2016-01-01

    The proper quality of construction of roads and railroads can be achieved by strengthening the of the foundation bed. Measurements and tests the number and order of the layers of geotextile layer of ground indicate the effectiveness of technical solutions involving the reinforcement laid horizontally. The offer technical use of the geotextile reinforcement in the ground layer substrates of roads indicates the possible effectiveness of the strengthening of the subsoil of roads and is also incl...

  5. Anchorage of Main Reinforcement in Lightweight Aggregate Concrete Beams

    DEFF Research Database (Denmark)

    Larsen, Henning

    1999-01-01

    The paper deals with the anchorage of reinforcement bars at end supports in beam component made of lightweight aggregate concrete with open structure.......The paper deals with the anchorage of reinforcement bars at end supports in beam component made of lightweight aggregate concrete with open structure....

  6. Computational modelling of chloride ion transport in reinforced concrete

    NARCIS (Netherlands)

    Meijers, S.J.H.; Bijen, J.M.J.M.; De Borst, R.; Fraaij, A.L.A.

    2001-01-01

    Exposure to a saline environment is a major threat with respect to the durability of reinforced concrete structures. The chloride ions, which are present in seawater and de-icing salts, are able to penetrate the concrete up to the depth of the reinforcement. They can eventually trigger a pitting cor

  7. 浅埋式桩基础钢筋混凝土拱桥桥墩防撞安全性评价与加固技术研究%Pier anti-collision safety evaluation of reinforced concrete arch bridge with shallow-buried piles and its strengthening technology research

    Institute of Scientific and Technical Information of China (English)

    吴超; 李德建; 宁夏元; 胡先春

    2013-01-01

    On the background of Yuan River bridge in Wuqiangxi,a method of pier anti-cillision safety evaluation,based on "Highway Bridge Code for Design",was put forward for reinforced concrete arch bridge with shallao-buried piles.On the basis of safety evaluation of Yuan River Bridge pier,a pier strengthening project of Yuan River Bridge in Wuqiangxi was proposed.In order to simulate the interaction of new and old concrete after strengthening of foundation,three-dimensional solid elements were adopted,where two situations of the interface between new and old concrete,i.e.,fully bonded or sliding were taken into account.The feasibility of this pier reinforcement project was studied,which can also provide reference for the similar bridge strengthening engineering.%以五强溪沅水大桥为工程背景,针对浅埋式桩基础钢筋混凝土拱桥,提出基于我国公路桥涵设计规范桥墩防撞安全性评价方法.通过对该桥的桥墩防撞安全性评价提出了相应的桥墩加固方案.采用三维实体单元来模拟基础加固后新老混凝土的共同作用,同时考虑新老混凝土接触面按完全粘结与滑动2种情况建立计算模型,对桥墩防撞加固方案的可行性进行了研究,亦可供同类桥梁加固参考.

  8. Efficacy of Thermally Conditioned Sisal FRP Composite on the Shear Characteristics of Reinforced Concrete Beams

    Directory of Open Access Journals (Sweden)

    Tara Sen

    2013-01-01

    Full Text Available The development of commercially viable composites based on natural resources for a wide range of applications is on the rise. Efforts include new methods of production and the utilization of natural reinforcements to make biodegradable composites with lignocellulosic fibers, for various engineering applications. In this work, thermal conditioning of woven sisal fibre was carried out, followed by the development of woven sisal fibre reinforced polymer composite system, and its tensile and flexural behaviour was characterized. It was observed that thermal conditioning improved the tensile strength and the flexural strength of the woven sisal fibre composites, which were observed to bear superior values than those in the untreated ones. Then, the efficacy of woven sisal fibre reinforced polymer composite for shear strengthening of reinforced concrete beams was evaluated using two types of techniques: full and strip wrapping techniques. Detailed analysis of the load deflection behaviour and fracture study of reinforced concrete beams strengthened with woven sisal under shearing load were carried out, and it was concluded that woven sisal FRP strengthened beams, underwent very ductile nature of failure, without any delamination or debonding of sisal FRP, and also increased the shear strength and the first crack load of the reinforced concrete beams.

  9. Normal Strength Steel Fiber Reinforced Concrete Subjected to Explosive Loading

    Directory of Open Access Journals (Sweden)

    Mohammed Alias Yusof

    2011-07-01

    Full Text Available This paper presents the results of an experimental investigation on the behavior of plain reinforced concrete and Normal strength steel fiber reinforced concrete panels (SFRC subjected to explosive loading. The experiment were performed by the Blast Research Unit Faculty of Engineering, University Pertahanan Nasional Malaysia A total of 8 reinforced concrete panels of 600mm x 600mm x 100mm were tested. The steel fiber reinforced concrete panels incorporated three different volume fraction, 0.5%, 1.0%, and 1.5% of hooked end steel fibers. The panels were subjected to explosive loading generated by the detonation of 1kg of explosive charge located at a 0.6m standoff. This investigation indicates that the steel fiber reinforced concrete panel containing of 1.5% volume fraction gave the best performance under explosive loading.

  10. Transporting fibres as reinforcement in self-compacting concrete

    NARCIS (Netherlands)

    Grünewald, S.; Walraven, J.C.

    2009-01-01

    The development of self-compacting concrete (SCC) was an important step towards efficiency at building sites, rationally producing prefabricated concrete elements, better working conditions and improved quality and appearance of concrete structures. By adding fibres to SCC bar reinforcement can be

  11. Flexural strength and ductility of reinforced concrete beams

    OpenAIRE

    Kwan, AKH; Ho, JCM; Pam, HJ

    2002-01-01

    In the design of reinforced concrete beams, especially those made of high-strength concrete and those in earthquake-resistant structures, both the flexural strength and ductility need to be considered. From the numerical results obtained in a previous study on the post-peak behaviour and flexural ductility of reinforced concrete beams, the interrelation between the flexural strength and the flexural ductility that could be simultaneously achieved was evaluated and plotted in the form of chart...

  12. Parameters That Effect the Interfacial Stresses in Fibre Reinforced Plastic Laminates Strengthened Rc Beams

    Directory of Open Access Journals (Sweden)

    Barış Sayın

    2010-01-01

    Full Text Available The use of externally bonded fiber-reinforced plastic (FRP laminates for strengthening of reinforced concrete beams has become an effective method. This method has been used because of the advantages of FRP materials such as their high strength-to-weight ratio, good corrosion resistance, and versatility in coping with different sectional shapes and corners. Many studies on this theme have been carried out since the early 1900s. In this study, interfacial stresses of reinforced concrete beams strengthened with FRP effect the parameters will be studied as experimental and numerical. Adhesives used in the beams applied to FRP's thickness, adhesive type and the state of the concrete surface, produced experimental samples are exposed to the bending effect will be studied as a comparative. Afterwards, by using the ANSYS® WB finite element program to model and analyze RC beams by externally bonding FRP will be carried out. Adhesive thickness, adhesive type, the concrete surface will be performed by entering the parameters for analysis of stress can be obtained as a result. Thus, the analytical expressions of stress and normal stress equations will establish should be modified. Finite element analysis and experimental results will be compared, compatibility investigated, the results and recommendations presented by the study be completed.

  13. Bond tests of fiberglass-reinforced plastic bars in concrete

    Energy Technology Data Exchange (ETDEWEB)

    Larralde, J.; Silva-Rodriquez, R.; Burdette, J.; Harris, B. (Drexel Univ., Philadelphia, PA (United States). Civil and Architectural Engineering Dept.)

    1994-07-01

    Fiberglass Reinforced Plastic (FRP) bars for concrete reinforcement have been commercially available for several years. The main advantage of such bar relative to the conventional steel reinforcing bars is their resistance to corrosion. The reinforced plastic bars are slightly different from the conventional steel bars both geometrically and mechanically. Thus, research is needed to understand their behavior and to be able to use them in concrete reinforcement with adequate reliability. Bond strength of reinforced plastic bars in concrete is one of the mechanical and behavioral differences with the steel bars. This paper presents the results of pullout and beam tests conducted to determine the bond stress-slip behavior of FRP bars in concrete.

  14. Neutron imaging of water penetration into cracked steel reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, P. [Center for Durability and Sustainability Studies of Shandong Province, Qingdao Technological University, Qingdao 266033 (China); Wittmann, F.H., E-mail: wittmann@aedificat.d [Center for Durability and Sustainability Studies of Shandong Province, Qingdao Technological University, Qingdao 266033 (China); Aedificat Institute Freiburg, Schlierbergstr. 80, D-79100 Freiburg (Germany); Zhao, T. [Center for Durability and Sustainability Studies of Shandong Province, Qingdao Technological University, Qingdao 266033 (China); Lehmann, E.H. [Neutron Imaging and Activation Group (NIAG), Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland)

    2010-04-01

    Service life and durability of reinforced concrete structures have become a crucial issue because of the economical and ecological implications. Service life of reinforced concrete structures is often limited by penetration of water and chemical compounds dissolved in water into the porous cement-based material. By now it is well-known that cracks in reinforced concrete are preferential paths for ingress of aggressive substances. Neutron radiography was successfully applied to study the process of water penetration into cracked steel reinforced concrete. In addition, the effectiveness of integral water repellent concrete to prevent ingress of water and salt solutions was investigated. Results are described in detail in this contribution. It will be shown that neutron radiography is a powerful method to visualize the process of water penetration into cracked and uncracked cement-based materials. On the basis of the obtained experimental data, it is possible to quantify the time-dependent water distributions in concrete with high accuracy and spatial resolution. It is of particular interest that penetration of water and salt solutions into damaged interfaces between concrete and steel can be visualized by means of neutron radiography. Deteriorating processes in cracked reinforced concrete structures can be studied in a completely new way. This advanced technology will help and find adequate ways to improve durability and service life of reinforced concrete structures. This will mean at the same time an essential contribution to improved sustainability.

  15. Numerical Limit Analysis of Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Larsen, Kasper Paaske

    methods provide engineers with valuable tools for limit sta- te analysis, their application becomes difficult with increased structural complexity. The main challenge is to solve the optimization problem posed by the extremum principles. This thesis is a study of how numerical methods can be used to solve...... limit state analysis problems. The work focuses on determination of the load bearing capacity of reinforced concrete structures by employing the lower bound theorem and a finite element method using equilibrium elements is developed. The recent year’s development within the field of convex optimization...... is developed for improved perfor- mance. An example is given in which an inverse T-beam is analyzed and the numerical results are compared to laboratory tests. The third and final element is a plane shell element capable of modeling membrane and plate bending behavior. The element employs a layered disk...

  16. Tendons Arrangement Effects on Reinforced Concrete Frames

    Directory of Open Access Journals (Sweden)

    Ayad B. Bahnam

    2013-05-01

    Full Text Available  The tendons arrangement effects on the response of reinforced concrete frame experiencing blast loads is investigated in this paper. The structure is modeled using nonlinear finite elements employing a bilinear hysteretic model. So that elements are used so that yielding of the structures could be accurately modeled and captured. The frame is analyzed using a non-linear, elastic-plastic finite element program written in code MATLAB. Six tendon architectures were investigated. A single tendon was placed between different floors and its effects investigated. From the obtained results, the ideal case which causes a reduction in the maximum displacement and the amount of permanent deflection without increase in the maximum structural shear forces greatly is obtained.

  17. Experimental investigation of the relation between damage at the concrete-steel interface and initiation of reinforcement corrosion in plain and fibre reinforced concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Solgaard, Anders Ole Stubbe; Pease, Bradley Justin;

    2013-01-01

    Cracks in covering concrete are known to hasten initiation of steel corrosion in reinforced concrete structures. To minimise the impact of cracks on the deterioration of reinforced concrete structures, current approaches in (inter)national design codes often limit the concrete surface crack width....... Recent investigations however, indicate that the concrete-reinforcement interfacial condition is a more fundamental criterion related to reinforcement corrosion. This work investigates the relation between macroscopic damage at the concrete-steel interface and corrosion initiation of reinforcement...... embedded in plain and fibre reinforced concrete. Comparisons of experimental and numerical results indicate a strong correlation between corrosion initiation and interfacial condition....

  18. CREATION OF MUSIC WITH FIBER REINFORCED CONCRETE

    Science.gov (United States)

    Kato, Hayato; Takeuchi, Masaki; Ogura, Naoyuki; Kitahara, Yukiko; Okamoto, Takahisa

    This research focuses on the Fiber Reinforcement Concrete(FRC) and its performance on musical tones. Thepossibility of future musical instruments made of this concrete is discussed. Recently, the technical properties of FRC had been improved and the different production styles, such as unit weight of binding material and volume of fiber in the structure, hardly affects the results of the acoustics. However, the board thickness in the FRC instruments is directly related with the variety of musical tone. The FRC musical effects were compared with those produced with wood on wind instruments. The sounds were compared with those produced with woodwind instruments. The sound pressure level was affected by the material and it becomes remarkably notorious in the high frequency levels. These differences had great influence on the spectrum analysis of the tone in the wind instruments and the sensory test. The results from the sensory test show dominant performances of brightness, beauty and power in the FRC instruments compared with those made of wood.

  19. Durability of concrete structures strengthened with FRP laminates

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Based on the fast freeze-thaw cycling test, the alkaline immersion test, the water immersion test and the wet-thermal exposure test, the influence of aggressive environments on mechanical behavior of FRP was studied. CFRP specimens subjected to aggressive environments showed good durability with no significant degradation in tensile strength and modulus; however, GFRP specimens exhibited a little decrease in mechanical property after aggressive environments exposure. Based on the fast freeze-thaw cycling test and the wet-thermal exposure test, the influence of aggressive environments on the bond behavior between FRP and concrete, mechanical behavior of concrete beams and columns strengthened with FRP laminates was studied. The results showed that the bond strength had a significant decrease compared with those specimens kept at room temperature, and the specimens strengthened with FRP exhibited good durability.

  20. Mechanical Properties of Layered Hybrid Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    YUAN Hai-qing; CHEN Jing-tao; ZHU Ji-dong

    2003-01-01

    To improve the mechanical properties of concrete,Layered Hybrid Fiber Reinforced Concrete (LHFRC) was developed in this paper.Through comparative tests,the effects of layered hybrid fibers on a series of mechanical properties of concrete were discussed.The mechanical properties include compressive strength,tensile strength,flexural strength,compressive stress-strain relationship,flexural toughness and cracking resistance of concrete.The testing results and analysis demonstrate that layered hybrid fibers can significantly improve the flexural strength,toughness and cracking resistance of concrete while the cost of concrete increases slightly.

  1. Shear crack propagation in MBC strengthened concrete beams”

    DEFF Research Database (Denmark)

    Täljsten, Björn; Blanksvärd, Thomas; Carolin, Anders

    2008-01-01

    Repair and upgrading existing concrete structures using FRPs and an epoxy adhesive as the bonding agent has some disadvantages when it comes to compatibility to the base concrete. Epoxies are often restricted by regulations of use, have low permeability which may create freeze/thaw problems, poor...... thermal compatibility to the base concrete and are often sensitive to the surface nature and surrounding temperature. By using mineral based composites (MBC) some of these challenges can be overcome. MBC refers here to a cementitious bonding agent and a carbon FRP grid. This paper is a part of an ongoing...... study of MBC systems. Emphasis is placed on the cracking behavior of the MBC system used for shear strengthening of RC beams. Traditional foil strain gauges and photometric measurements have been used for monitoring of the cracking behavior. In this study it is shown that the use of mineral based shear...

  2. Investigation of basalt plastic reinforcement and its Adhesion with Concrete

    Directory of Open Access Journals (Sweden)

    Kustikova Yulia Olegovna

    2014-03-01

    Full Text Available The load-bearing capacity and durability of concrete structures with metal or other reinforcement depends on their physical and mechanical properties and adhesion values with concrete. In this regard, there is an urgent need in the definition of adhesion of basalt reinforcement and concrete of various compositions and classes. One of the main problems with the use of basalt rods in concrete structures is - providing a high degree of load-carrying capacity in different conditions of stress-strain state of the structure, and the related amount of its adhesion with concrete. Meeting these requirements can be achieved with load-bearing capacity of individual rods, adhesion value, in general, of basalt reinforcement with concrete.

  3. Nonlinear Analysis of External Prestressed Reinforced Concrete Beams with BFRP and CFRP

    Directory of Open Access Journals (Sweden)

    Haleem K. Hussain

    2017-05-01

    Full Text Available The traditional strengthening methods for concrete structure (girders, beams, columns…. consuming time and could be an economical, a new modern repair methods using the Carbon Fiber Reinforced Polymers (CFRP and Basalt Fiber Reinforced Polymer (BFRP as a laminate strips or bars,and considered a competitive solution that will increase the life-cycle of repaired structures. This study investigated the strengthen reinforced concrete girder. Nonlinear analysis have been adopted to the models using FEM analysis (ANSYS to simulate the theoretical results compared with experimental results.Using finite element packages, more efficient and better analyses can be made to fully understand the response of individual structural components and their contribution to a structure as a whole.Three type of material are used in this study as an external prestressed wire (steel, CFRP and BFRP. The prestressed beam is modeled as simply supported beam with two concentrated point load. The results showed that all tested strengthening beam increased the load carryingcapacity of the beams depend on prestressing force. Obtained Result was compared for different type of beam.This study also was enlarged to include using CFRP and BFRPbarwhich are light weight and moredurable, lead to ease of handling and maintenance. The research conducted analytical work to evaluate the effectiveness of concrete beams reinforced normally by the use of CFRP and BFRP bars. The results showed a significant gain in the beam’s ultimate capacities using CFRP bars comparing with beam reinforced with BFRP bar and reference beam

  4. Flexural behavior of reinforced concrete beams: Comparative analysis between high-performance concrete and ordinary concrete

    Directory of Open Access Journals (Sweden)

    Hamrat Mostefa

    2014-04-01

    Full Text Available This paper presents an experimental study on the flexural strength of reinforced concrete beams made with high performance concrete (HPC and ordinary concrete (OC. We are carried an experimental campaign aimed comes in three points: 1- the study of the law of behavior of the two materials (OC and HPC, 2- the influence of the compressive strength of concrete and the rate of longitudinal reinforcement on the loaddeflection behavior and ductility index, 3- comparative analysis (ACI318, Eurocode 2 and BS8110 against the crack opening. Test results showed that the capacity of the beams in HPC is higher (6% to 20 % than the beams in OC. The use of HPC is more efficient than the OC to delay the first cracking. The average value of the ductility index for the beams in HPC is 1.30 times those beams in OC. The formula for calculating the crack opening derived of the Eurocode 2 gives the best prediction the crack width of beams (for both types of concrete.

  5. Discrete fiber-reinforced polyurea systems for infrastructure strengthening and blast mitigation

    Science.gov (United States)

    Carey, Natalia L.

    The research presented in this dissertation focused on evaluating the effectiveness of various blast mitigation materials and coating technologies to be used for enhancing blast resistance of structural members. Mechanical properties and blast mitigation performance of different discrete fiber-reinforced polyurea (DFRP) systems were investigated through experimental and analytical work. Four technical papers discuss the research efforts conducted within this dissertation. The first paper examined the development and characterization of different DFRP systems for infrastructure strengthening and blast retrofit. The behavior of various systems which consisted of chopped E-glass fibers discretely integrated in with the polyurea matrix was evaluated through coupon tensile testing. The addition of glass fiber to a polymer coating provided improved stiffness and strength to the composite system while the polyurea base material provided ductility. The second paper evaluated the behavior of hybrid, plain, and steel fiber-reinforced concrete panels coated with various polyurea and DFRP systems under blast loading. Hybrid panels demonstrated higher blast mitigation performance compared to plain and steel fiber-reinforced concrete panels due to sacrificial hybrid layer. The addition of plain polyurea or DFRP systems on the tension side improved panel performance by containing fragmentation during a blast event. The third paper presents an analytical investigation conducted using the explicit finite element program LS-DYNA to model panel and coating response under blast loading. Several modeling solutions were undertaken and compared for concrete formulation. Modeling results were analyzed and compared to the experimental work to validate the conclusions. The final paper describes an internal equilibrium mechanics based model developed to predict the flexural capacity of reinforced concrete beams strengthened with various DFRP systems. The developed model was validated using

  6. Transport and Corrosion Behavior of Cracked Reinforced Concrete

    DEFF Research Database (Denmark)

    Pease, Bradley Justin

    to enter the concrete. This is, among others, important in the corrosion of reinforcing steel. When cracks protrude to the depth of reinforcing steel, liquids containing aggressive ions (i.e. chlorides associated with salts and sea water) may rapidly access and initiate corrosion of the reinforcing...... structures. These models currently lack some of the scientific validity to fully represent actual field structures, i.e. structures containing cracks. Further understanding, therefore is needed on the effect cracks have on transport and corrosion in reinforced concrete. The fundamental mechanisms...... of transport and corrosion in cracked, reinforced concrete are not yet fully understood. The scope of this study therefore is to develop a link between concrete cracks and the relevant transport mechanism(s) under particular environmental conditions. It is envisioned that a finite element model...

  7. Shear reinforced beams in autoclaved aerated concrete

    DEFF Research Database (Denmark)

    Cornelius, Thomas

    2010-01-01

    Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different combinat......Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different...

  8. Surface treated polypropylene (PP) fibres for reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    López-Buendía, Angel M., E-mail: buendia@uv.es [AIDICO Technological Institute of Construction, Benjamin Franklin 17, 46380 Paterna, Valencia (Spain); Romero-Sánchez, María Dolores [AIDICO Technological Institute of Construction, Marble Technical Unit, Camí de Castella 4, 03660 Novelda. Alicante (Spain); Climent, Verónica [Lafarge Cementos, Polígono Sepes, Isaac Newton s/n, 46500 Sagunto, Valencia (Spain); Guillem, Celia [AIDICO Technological Institute of Construction, Marble Technical Unit, Camí de Castella 4, 03660 Novelda. Alicante (Spain)

    2013-12-15

    Surface treatments on a polypropylene (PP) fibre have contributed to the improvement of fibre/concrete adhesion in fibre-reinforced concrete. The treatments to the PP fibre were characterized by contact angle measurements, ATR-IR and XPS to analyse chemical alterations. The surface topography and fibre/concrete interaction were analysed by several microscopic techniques, namely optical petrographic, and scanning electron microscopy. Treatment modified the surface chemistry and topography of the fibre by introducing sodium moieties and created additional fibre surface roughness. Modifications in the fibre surface led to an increase in the adhesion properties between the treated fibres and concrete and an improvement in the mechanical properties of the fibre-reinforced concrete composite as compared to the concrete containing untreated PP fibres. Compatibility with the concrete and increased roughness and mineral surface was also improved by nucleated portlandite and ettringite mineral association anchored on the alkaline PP fibre surface, which is induced during treatment.

  9. The Mechanical Properties of Polypropylene Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    LI Bei-xing; CHEN Ming-xiang; CHENG Fang; LIU Lu-ping

    2004-01-01

    The compressive, shear strengths and abrasion-erosion resistance as well as flexural properties of two polypropylene fiber reinforced concretes and the comparison with a steel fiber reinforced concrete were reported.The exprimental results show that a low content of polypropylene fiber (0.91kg/m3 of concrete) slightly decreases the compressive and shear strengths, and appreciably increased the flexural strength, but obviously enhances the toughness index and fracture energy for the concrete with the same mix proportion, consequently it plays a role of anti-cracking and improving toughness in concrete. Moreover, the polypropylene mesh fiber is better than the polypropylene monofilament fiber in improving flexural strength and toughness of concrete, but the two types of polypropylene fibers are inferior to steel fiber. All the polypropylene and steel fibers have no great beneficial effect on the abrasion-erosion resistance of concrete.

  10. Bond Properties and Experimental Methods of Textile Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Textile reinforced concrete(TRC, for short) allows the low size production and offers a high effectiveness of the reinforcement by using continuous roving instead of short-chopped fibers. However, whether textiles can cooperate with concrete very well depends on the bond between them. In this paper, the bonding mechanism that the stress was transferred from fine concrete to textile was analyzed, and the influences of the initial bond length of textile, the surface treatment of textile, the strength and workability of concrete as well as the level of prestressing force on bond behavior were investigated on the basis of pull-out tests. The results reveal that with initial bond length increasing, the maximum pull force increases, and increasing concrete strength and improving workability of concrete matrix, epoxy resin impregnating and sand covering of textile as well as prestressing textile can obviously increase the bond strength between the textile and concrete.

  11. Compressive behaviour at High Temperatures of Fibre Reinforced Concretes

    Directory of Open Access Journals (Sweden)

    S. O. Santos

    2009-01-01

    Full Text Available This paper summarizes the research that is being carried out at the Universities of Coimbra and Rio de Janeiro, on fibre reinforced concretes at high temperatures. Several high strength concrete compositions reinforced with fibres (polypropylene, steel and glass fibres were developed. The results of compressive tests at high temperatures (300 °C, 500 °C and 600 °C and after heating and cooling down of the concrete are presented in the paper. In both research studies, the results indicated that polypropylene fibers prevent concrete spalling. 

  12. Does contingent reinforcement strengthen operant behavior?

    OpenAIRE

    Nevin, John A.; Smith, Laurence D.; Roberts, Jean

    1987-01-01

    In Experiment 1, pigeons were trained to peck keys with equal food-reinforcement schedules in components that ended with either noncontingent or contingent transitions to a third component with a five-fold richer schedule. Response rates were higher in the initial component with contingent transitions, but resistance to prefeeding or extinction was not consistently greater. Experiment 2 also included noncontingent or contingent transitions to a signaled period of nonreinforcement. There was n...

  13. Strength Modeling of Reinforced Concrete Beam with Externally Bonded FRP Reinforcement

    Directory of Open Access Journals (Sweden)

    N. Pannirselvam

    2008-01-01

    Full Text Available This research study presents the evaluation of the structural behaviour of reinforced concrete beams with externally bonded Fibre Reinforced Polymer (FRP reinforcements. Three different steel ratios with two different Glass Fibre Reinforced Polymer (GFRP types and two different thicknesses in each type of GFRP were used. Totally fifteen rectangular beams of 3 m length were cast. Three rectangular beams were used as reference beam (Control Beams and the remaining were fixed with GFRP laminates on the soffit of the rectangular beam. The variables considered for the study includes longitudinal steel ratio, type of GFRP laminates, thickness of GFRP laminates and composite ratios. Flexural test, using simple beam with third-point loading was adopted to study the performance of FRP plated beams interms flexural strength, deflection, ductility and was compared with the unplated beams. The test results show that the beams strengthened with GFRP laminates exhibit better performance. The flexural strength and ductility increase with increase in thickness of GFRP plate. The increase in first crack loads was up to 88.89% for 3 mm thick WRGFRP plates and 100.00% for 5 mm WRGFRP plated beams and increase in ductility interms of energy and deflection was found to be 56.01 and 64.69% respectively with 5 mm thick GFRP plated beam. Strength models were developed for predicting the flexural strength (ultimate load, service load and ductility of FRP beams. The strength model developed give prediction matching the measurements.

  14. Potential of Carbon Nanotube Reinforced Cement Composites as Concrete Repair Material

    Directory of Open Access Journals (Sweden)

    Tanvir Manzur

    2016-01-01

    Full Text Available Carbon nanotubes (CNTs are a virtually ideal reinforcing agent due to extremely high aspect ratios and ultra high strengths. It is evident from contemporary research that utilization of CNT in producing new cement-based composite materials has a great potential. Consequently, possible practical application of CNT reinforced cementitious composites has immense prospect in the field of applied nanotechnology within construction industry. Several repair, retrofit, and strengthening techniques are currently available to enhance the integrity and durability of concrete structures with cracks and spalling, but applicability and/or reliability is/are often limited. Therefore, there is always a need for innovative high performing concrete repair materials with good mechanical, rheological, and durability properties. Considering the mechanical properties of carbon nanotubes (CNTs and the test results of CNT reinforced cement composites, it is apparent that such composites could be used conveniently as concrete repair material. With this end in view, the applicability of multiwalled carbon nanotube (MWNT reinforced cement composites as concrete repair material has been evaluated in this study in terms of setting time, bleeding, and bonding strength (slant shear tests. It has been found that MWNT reinforced cement mortar has good prospective as concrete repair material since such composites exhibited desirable behavior in setting time, bleeding, and slant shear.

  15. Ambient Vibration Test on Reinforced Concrete Bridges

    Directory of Open Access Journals (Sweden)

    Idris Nurul Shazwin

    2016-01-01

    Full Text Available An investigation was carried out to determine dynamic characteristic of reinforced concrete (RC bridges by using ambient vibration test (AVT. The ambient vibration sources on bridges may come from traffic, wind, wave motion and seismic events. AVT describes the dynamic characteristics of the bridge and ground by measuring the natural frequencies using highly sensitive seismometer sensor. This test is beneficial due to light weight equipment and smaller number of operator required, cheap and easy to be handled. It is able to give a true picture of the bridge dynamic behavior without any artificial force excitation when vibration data is recorded. A three-span reinforced concrete bridge located in Sri Medan, Batu Pahat, Johor was measured by using microtremor equipment consist of three units of 1 Hz eigenfrequency passive sensors used in this test was performed in normal operating condition without excitation required from any active sources or short period noise perturbations. Ten measurements were conducted on the bridge deck and ten measurements on the ground surface in order to identify the natural frequencies of the bridge. Several peak frequencies were identified from three components of Fourier Amplitude Spectra (FAS in transverse (North-South, longitudinal (East-West and vertical (Up-Down direction as well as squared average Horizontal to Vertical Spectral Ratio (HVSR of ground response, computed by using Geopsy software. From the result, it was expected the bridge have five vibration modes frequencies in the range of 1.0 Hz and 7.0 Hz with the first two modes in the transverse and longitudinal direction having a frequency 1.0 Hz, the third mode is 2.2 Hz in transverse direction, fourth and fifth mode is 5.8 Hz and 7.0 Hz. For ground natural frequencies are in range 1.0 Hz to 1.3 Hz for North-South direction and 1.0 Hz to 1.6 Hz for East-West direction. Finally the results are compared with several empirical formulas for simple

  16. Stochastic modeling of reinforced concrete structures exposed to chloride attack

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Frier, Christian

    2004-01-01

    the reinforcement exceeds a critical threshold value. In the present paper a stochastic model is described by which the chloride content in a reinforced concrete structure can be estimated. The chloride ingress is modeled by a 2-dimensional diffusion process and the diffusion coefficient, surface chloride......For many reinforced concrete structures corrosion of reinforcement is an important problem since it can result in expensive maintenance and repair actions. Further, a significant reduction of the load-bearing capacity can occur. One mode of corrosion initiation is that the chloride content around...

  17. Experimental Study on Voided Reinforced Concrete Beams with Polythene Balls

    Science.gov (United States)

    Sivaneshan, P.; Harishankar, S.

    2017-07-01

    The primary component in any structure is concrete, that exist in buildings and bridges. In present situation, a serious problems faced by construction industry is exhaustive use of raw materials. Recent times, various methods are being adopted to limit the use of concrete. In structural elements like beams, polythene balls can be induced to reduce the usage of concrete. A simply supported reinforced concrete beam has two zones, one above neutral axis and other below neutral axis. The region below neutral axis is in tension and above neutral axis is in compression. As concrete is weak in tension, steel reinforcements are provided in tension zone. The concrete below the neutral axis acts as a stress transfer medium between the compression zone and tension zone. The concrete above the neutral axis takes minimum stress so that we could partially replace the concrete above neutral axis by creating air voids using recycled polythene balls. Polythene balls of varying diameters of 75 mm, 65 mm and 35 mm were partially replaced in compression zone. Hence the usage of concrete in beams and self-weight of the beams got reduced considerably. The Load carrying capacity, Deflection of beams and crack patterns were studied and compared with conventional reinforced concrete beams.

  18. Experimental Study on Electric Properties of Carbon Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    According to the phenomenon that the physical properties have a great effect on the electric capability of carbon fiber reinforced concrete, the author researched the relationship between DC resistance of carbon fiber reinforced concrete and curing age using the two-probe method. Then the effect of insulative area,location and quantity on DC resistance of carbon fiber reinforced concrete was investigated at different curing age with analysis of hydration. The results suggest that DC resistance increases greatly with its curing age, which illustrates the relationship like Gaussian curve. In every curing ages the electric capability of carbon fiber reinforced concrete weakenes with the increase of insulative area. In same curing ages, section and insulative area, the more the quantity of insulation, the stronger the conductibility. The insulative location in optimal position can only result in optimal conductibility.

  19. Verification of Properties of Concrete Reinforcement Bars: Nigeria ...

    African Journals Online (AJOL)

    Nekky Umera

    from the producing mills but purchase them as groups of single bars from the ... determining the extent to which they conform to the requirements of. International ... the most widely used bar sizes for the local concrete reinforcement needs.

  20. Bond Strength Degradation of Corrosive Reinforced Lightweight Concrete

    Institute of Scientific and Technical Information of China (English)

    CHEN Yueshun; LU Yiyan; LI Houxiang; ZENG Sanhai

    2007-01-01

    The influence of reinforced bar corrosion on the bond degradation in lightweight concrete was studied. Accelerated constant current corrosion tests were performed on lightweight reinforced concrete samples, and the influential factors, such as protective layer thickness, reinforced bar diameter and corrosive level were investigated. The constant current step method was used to measure the electric resistance of the concrete protective cover, which was used to characterize the corrosion level of the rebar. Experimental results indicated that the corrosive resistance increased with increasing the cover dimension and decreasing the reinforced bar diameter, and the rate of decrease in the specimen impedance after cracking depended on the cover dimension. A new medium was offered for the further research on the performance degradation of corrosion lightweight concrete.

  1. Impact of biofouling on corrosion resistance of reinforced concrete

    Digital Repository Service at National Institute of Oceanography (India)

    Patil, B.T.; Gajendragad, M.R.; Ranganna, G.; Wagh, A.B.; Sudhakaran, T.

    the structure from deterioration; a nonuniform deposit can lead to severe localized pitting corrosion. To study this cylindrical reinforced concrete electrodes were exposed to seawater. They were periodically removed and examined for the presence of fouling...

  2. Seismic fragility of a reinforced concrete structure

    Energy Technology Data Exchange (ETDEWEB)

    Kurmann, Davide [Axpo Power AG, Baden (Switzerland); Proske, Dirk [Axpo Power AG, Doettingen (Switzerland); Cervenka, Jan [Cervenka Consulting, Prague (Czech Republic)

    2013-05-15

    Structures can be exposed to seismic loading. For structures of major importance, extreme seismic loadings have to be considered. The proof of safety for such loadings requires sophisticated analysis. This paper introduces an analysis method which of course still includes simplifications, but yields to a far more realistic estimation of the seismic load bearing capacity of reinforced concrete structures compared to common methods. It is based on the development of pushover curves and the application of time-histories for the dynamic model to a representative harmonic oscillator. Dynamic parameters of the oscillator, such as modal mass and damping are computed using a soil-structure-interaction analysis. Based on the pushover-curve nonlinear force-deformation-capacities are applied to the oscillator including hysteresis behaviour characteristics. The oscillator is then exposed to time-histories of several earthquakes. Based on this computation the ductility is computed. The ductility can be scaled based upon the scaling of the time-histories. Since both, the uncertainty of the earthquake by using different timehistories and the uncertainty of the structure by using characteristic and mean material values, are considered, the uncertainty of the structure under seismic loading can be explicitly represented by a fragility. (orig.)

  3. Shear Strengthening of RC Beams Using Sprayed Glass Fiber Reinforced Polymer

    Directory of Open Access Journals (Sweden)

    Sayed Mohamad Soleimani

    2012-01-01

    Full Text Available The effectiveness of externally bonded sprayed glass fiber reinforced polymer (Sprayed GFRP in shear strengthening of RC beams under quasi-static loading is investigated. Different techniques were utilized to enhance the bond between concrete and Sprayed GFRP, involving the use of through bolts and nuts paired with concrete surface preparation through sandblasting and through the use of a pneumatic chisel prior to Sprayed GFRP application. It was found that roughening the concrete surface using a pneumatic chisel and using through bolts and nuts were the most effective techniques. Also, Sprayed GFRP applied on 3 sides (U-shaped was found to be more effective than 2-sided Sprayed GFRP in shear strengthening. Sprayed GFRP increased the shear load-carrying capacity and energy absorption capacities of RC beams. It was found that the load-carrying capacity of strengthened RC beams was related to an effective strain of applied Sprayed GFRP. This strain was related to Sprayed GFRP configuration and the technique used to enhance the concrete-FRP bond. Finally, an equation was proposed to calculate the contribution of Sprayed GFRP in the shear strength of an RC beam.

  4. Analysis of reinforced concrete building according to the EC 8

    OpenAIRE

    Dimec, Andrej

    2009-01-01

    In the Thesis the analysis and the software based design of the six-storey reinforced concrete wall building according to the European Standard Eurocode is presented. The structural system of the building consists of reinforced concrete walls. First the calculation of the self weight, variable actions, snow and the wind loads has been examined. The major part of the thesis deals with seismic analysis, which was performed by the modal analysis and simplified non-linear seismic a...

  5. Design of macro-synthetic fibre reinforced concrete pipes

    OpenAIRE

    Fuente, Albert de la; Escariz, Renata Campos; Figueiredo,Antonio Domingues de; Aguado, Antonio

    2013-01-01

    This paper presents an experimental campaign in which concrete pipes were manufactured using plastic fibres as the sole reinforcement material. In this regard, it has been demonstrated that the use of plastic fibres is compatible with pipe production systems, and that, when subjected to the crushing test (CT), plastic fibre reinforced pipes yield strength classes that are attractive in terms of the growth of this material in the concrete pipe industry. Moreover, the results obtained from b...

  6. Reinforcement of the concrete base slab of the ATLAS cavern

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    Photo 02: UX15 cavern, preparation for concreting of base slab first lift. Photo 05: UX15 cavern, placing of reinforcement for base slab first lift. Photo 07: UX15 cavern, preparation for concreting of base slab first lift. Photo 09: UX15 cavern, placing of reinforcement for base slab first lift. Photo 10: UX15 cavern, view into PX14 shaft above. Photo 12: UX15 cavern, temporary access platform of RB16 tunnel. Photo 15: UJ17 chamber, invert excavation.

  7. Experimental Investigation on Contribution of CFRP Attachment to Durability of Reinforced Concrete Structure Subjected to Chloride Attack

    Institute of Scientific and Technical Information of China (English)

    Chen Fengshan; Zhao Guofan; Pan Deqiang

    2006-01-01

    The function of externally-bonded carbon fiber reinforced polymer (CFRP) in preventing chloride from entering into concrete is verified by experiment. The results show that externally-bonded CFRP can be considered as a part of corrosion prevention system of strengthened concrete structures subjected to chloride ingress, and the contribution of CFRP should be considered in evaluation of durability of reinforced concrete structures with externally-bonded CFRP. With the effective shielding function of CFRP considered, an equation for residual lifetime prediction of concrete structures with externally-bonded CFRP is derived from Ficks dispersion law. CFRP has two functions for coastal concrete structures, including strengthening and increasing durability as part of corrosion prevention system.

  8. Seismic Material Properties of Reinforced Concrete and Steel Casing Composite Concrete in Elevated Pile-Group Foundation

    Directory of Open Access Journals (Sweden)

    Zhou Mi

    2015-09-01

    Full Text Available The paper focuses on the material mechanics properties of reinforced concrete and steel casing composite concrete under pseudo-static loads and their application in structure. Although elevated pile-group foundation is widely used in bridge, port and ocean engineering, the seismic performance of this type of foundation still need further study. Four scale-specimens of the elevated pile-group foundation were manufactured by these two kinds of concrete and seismic performance characteristic of each specimen were compared. Meanwhile, the special soil box was designed and built to consider soil-pile-superstructure interaction. According to the test result, the peak strength of strengthening specimens is about 1.77 times of the others and the ultimate displacement is 1.66 times of the RC specimens. Additionally, the dissipated hysteric energy capability of strengthening specimens is more than 2.15 times of the others as the equivalent viscous damping ratio is reduced by 50%. The pinching effect of first two specimens is more obvious than latter two specimens and the hysteretic loops of reinforced specimens are more plumpness. The pseudo-static tests also provided the data to quantitatively assessment the positive effect of steel casing composite concrete in aseismatic design of bridge.

  9. Stochastic Models for Chloride-Initiated Corrosion in Reinforced Concrete

    DEFF Research Database (Denmark)

    Engelund, Svend; Sørensen, John Dalsgaard

    Corrosion of the reinforcement in concrete structures can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is when the chloride content around the reinforcement exceeds a threshold value. In the present paper a statistical model is developed by which t...... the chloride content in a 1reinforced concrete structure can be predicted. The model parameters are estimated on the basis of measurements. The distribution of the time to initiation of corrosion is estimated by FORMISORM-analysis.......Corrosion of the reinforcement in concrete structures can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is when the chloride content around the reinforcement exceeds a threshold value. In the present paper a statistical model is developed by which...

  10. Reinforced concrete bridges: effects due to corrosion and concrete young modulus variation

    Directory of Open Access Journals (Sweden)

    P. T. C. Mendes

    Full Text Available Most of the Brazilian bridges of federal road network are made of reinforced concrete and are more than 30 years old, with little information about the mechanical properties of their constitutive materials. Along the service life of these bridges much modification occurred on vehicles load and geometry and in design standard. Many of them show signs of concrete and steel deterioration and their stability conditions are unknown. With the aim of contributing to the structural evaluation of reinforced concrete bridges it was decided to analyze the stresses in reinforced concrete bridge sections to verify the effects due to reinforcement corrosion and variation of the concrete Young modulus on the stress distribution regarding several load patterns and cracking effects in a representative bridge of the Brazilian road network with different longitudinal reinforcement taxes and two concrete Young modulus, Ec and 0.5Ec, and with different percentage of reinforcement corrosion. The analysis considered two finite element models: frame and shell elements as well as solid elements. The results indicate that these variation effects are more significant in reinforcement bars than in concrete.

  11. Prevention of reinforcement corrosion by hydrophobic treatment of concrete

    NARCIS (Netherlands)

    Polder, R.B.; Borsje, H.; Vries, H. de

    2001-01-01

    Corrosion of reinforcement in concrete bridge decks may occur due to penetration of de-icing salts, even in the presence of an asphalt overlay. This paper reports a laboratory study into additional protection of concrete by hydrophobic treatment. It was found that hydrophobic treatment strongly redu

  12. Corrosion protection of reinforcement by hydrophobic treatment of concrete

    NARCIS (Netherlands)

    Polder, R.B.; Vries, H. de

    1999-01-01

    Penetration of de-icing salts into concrete bridge decks may cause corrosion of reinforcement. Hydrophobic treatment of concrete was studied as additional protection. It was shown that hydrophobic treatment strongly reduces chloride ingress, during semi-permanent contact and in wetting/drying situat

  13. Cracking in reinforced concrete structures due to imposed deformations

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, A.

    1997-04-01

    This thesis is concerned with modeling of the cracking process in reinforced concrete due to imposed deformations. Cracking is investigated both at early ages, during hydration, and at mature age when the final properties of the concrete are reached. One of the most important material characteristics of the concrete at early ages, the Young`s modulus is determined by means of a dynamic method called the resonance frequency method. 40 refs

  14. Shear Reinforcement Requirements for High-Strength Concrete Bridge Girders

    OpenAIRE

    Ramirez, J. A.; Aguilar, Gerardo

    2005-01-01

    A research program was conducted on the shear strength of high-strength concrete members. The objective was to evaluate the shear behavior and strength of concrete bridge members with compressive strengths in the range of 10 000 to 15 000 psi. The goal was to determine if the current minimum amount of shear reinforcement together with maximum spacing limits in the 2004 AASHTO LRFD Specifications, and the upper limit on the nominal shear strength were applicable to concrete compressive strengt...

  15. Material and Flexural Properties of Fiber-reinforced Rubber Concrete

    Science.gov (United States)

    Helminger, Nicholas P.

    The purpose of this research is to determine the material properties of rubber concrete with the addition of fibers, and to determine optimal mixture dosages of rubber and fiber in concrete for structural applications. Fiber-reinforced concrete and rubberized concrete have been researched separately extensively, but this research intends to combine both rubber and fiber in a concrete matrix in order to create a composite material, fiber-reinforced rubber concrete (FRRC). Sustainability has long been important in engineering design, but much of the previous research performed on sustainable concrete does not result in a material that can be used for practical purposes. While still achieving a material that can be used for structural applications, economical considerations were given when choosing the proportions and types of constituents in the concrete mix. Concrete mixtures were designed, placed, and tested in accordance with common procedures and standards, with an emphasis on practicality. Properties that were investigated include compressive strength, tensile strength, modulus of elasticity, toughness, and ductility. The basis for determining the optimal concrete mixture is one that is economical, practical, and exhibits ductile properties with a significant strength. Results show that increasing percentages of rubber tend to decrease workability, unit weight, compressive strength, split tensile strength, and modulus of elasticity while the toughness is increased. The addition of steel needle fibers to rubber concrete increases unit weight, compressive strength, split tensile strength, modulus of elasticity, toughness, and ductility of the composite material.

  16. Strengthening of Corroded Reinforced SCC-RAP Members with CFRP

    Directory of Open Access Journals (Sweden)

    Ahmed Abdel-Mohti

    2016-01-01

    Full Text Available Corrosion is one of the major problems affecting the durability of reinforced concrete (RC structures. This paper investigates the effect of rebar corrosion on the performance of reinforced self-consolidating concrete (SCC members and the effectiveness of repair. A control RC member, which has no corrosion problem, was prepared to compare against corroded and repaired members. A number of reinforced concrete members having up to 50% corrosion level were constructed and tested to study the effect of corrosion on the structural performance of RC members. The beams with corrosion problem were repaired using carbon fiber reinforced polymer (CFRP sheets and U-wraps. All of the beams constructed, which are either not repaired or repaired, in this study were tested under two static line loads until failure. The effect of corrosion and effectiveness of repairing technique were assessed by evaluating the performance in terms of load carrying capacity, deflection, and ductility. Test results revealed that as the corrosion level increases, the loss in load carrying capacity increases. Repairing using CFRP improved the performance of corroded members. For example, when 50% corrosion level was achieved, the beam lost approximately 57% of its load carrying capacity, but when it was repaired, it recovered about 42% of its load carrying capacity.

  17. Behaviour of concrete beams reinforced withFRP prestressed concrete prisms

    Science.gov (United States)

    Svecova, Dagmar

    The use of fibre reinforced plastics (FRP) to reinforce concrete is gaining acceptance. However, due to the relatively low modulus of FRP, in comparison to steel, such structures may, if sufficient amount of reinforcement is not used, suffer from large deformations and wide cracks. FRP is generally more suited for prestressing. Since it is not feasible to prestress all concrete structures to eliminate the large deflections of FRP reinforced concrete flexural members, researchers are focusing on other strategies. A simple method for avoiding excessive deflections is to provide sufficiently high amount of FRP reinforcement to limit its stress (strain) to acceptable levels under service loads. This approach will not be able to take advantage of the high strength of FRP and will be generally uneconomical. The current investigation focuses on the feasibility of an alternative strategy. This thesis deals with the flexural and shear behaviour of concrete beams reinforced with FRP prestressed concrete prisms. FRP prestressed concrete prisms (PCP) are new reinforcing bars, made by pretensioning FRP and embedding it in high strength grout/concrete. The purpose of the research is to investigate the feasibility of using such pretensioned rebars, and their effect on the flexural and shear behaviour of reinforced concrete beams over the entire loading range. Due to the prestress in the prisms, deflection of concrete beams reinforced with this product is substantially reduced, and is comparable to similarly steel reinforced beams. The thesis comprises both theoretical and experimental investigations. In the experimental part, nine beams reinforced with FRP prestressed concrete prisms, and two companion beams, one steel and one FRP reinforced were tested. All the beams were designed to carry the same ultimate moment. Excellent flexural and shear behaviour of beams reinforced with higher prestressed prisms is reported. When comparing deflections of three beams designed to have the

  18. Interface Capacity of Repaired Concrete Columns Strengthened with RC Jackets

    Directory of Open Access Journals (Sweden)

    Achillopoulou Dimitra

    2014-12-01

    Full Text Available The study describes the retrofit of repaired elements by reinforced concrete (RC jacketing conducted to quantify the influence of initial construction deficiencies and of different type of anchors to the ability of the interface to transfer loads. Sixteen specimens (section scale 1:2 were designed with variables the initial deficiencies and the confinement ratio. The results indicate that: a the maximum resistance load and dissipated energy of initially damaged specimens are decreased; b surpassing a specific amount of damage, columns even suitably repaired present lower strain capacity, c welded bars lead to buckling of longitudinal bars.

  19. Strengthening of Concrete Structures with cement based bonded composites

    DEFF Research Database (Denmark)

    Täljsten, Björn; Blanksvärd, Thomas

    2008-01-01

    Polymers). The method is very efficient and has achieved world wide attention. However, there are some drawbacks with the use of epoxy, e.g. working environment, compatibility and permeability. Substituting the epoxy adherent with a cement based bonding agent will render a strengthening system...... with improved working environment and better compatibility to the base concrete structure. This study gives an overview of different cement based systems, all with very promising results for structural upgrading. Studied parameters are structural retrofit for bending, shear and confinement. It is concluded...

  20. Nonlinear analysis of concrete beams strengthened by date palm fibers

    Science.gov (United States)

    Bouzouaid, Samia; Kriker, Abdelouahed

    2017-02-01

    The behaviour of concrete beams strengthened with date palm fibers was studied by Nonlinear Finite Element Analysis using ANSYS software. Five beams that were experimentally tested in a previous research were considered. The results obtained from the ANSYS finite element analysis are compared with the experimental data for the five beams with different amounts of fibres, ranging from 0.2% to 0.5% by a step equal to 0.1% and with a fibre length of 0.04 m. The results obtained by FEA showed good agreement with those obtained by the experimental program. This research demonstrates the ability of FEA in predicting the behaviour of beams strengthened with Date Palm fibers. It will help researchers in studying beams with different configurations without the need to go through the lengthy experimental testing programs.

  1. Nondestructive inspection of corrosion and delamination at the concrete-steel reinforcement interface

    Science.gov (United States)

    Miller, Tri Huu

    The proposed study explores the feasibility of detecting and quantifying corrosion and delamination (physical separation) at the interface between reinforcing steel bars and concrete using ultrasonic guided waves. The problem of corrosion of the reinforcing steel in structures has increased significantly in recent years. The emergence of this type of concrete deterioration, which was first observed in marine structures and chemical manufacturing plants, coincided with the increased applications of deicing salts (sodium and calcium chlorides) to roads and bridges during winter months in those states where ice and snow are of major concern. Concrete is strengthened by the inclusion of the reinforcement steel such as deformed or corrugated steel bars. Bonding between the two materials plays a vital role in maximizing performance capacity of the structural members. Durability of the structure is of concern when it is exposed to aggressive environments. Corrosion of reinforcing steel has led to premature deterioration of many concrete members before their design life is attained. It is therefore, important to be able to detect and measure the level of corrosion in reinforcing steel or delamination at the interface. The development and implementation of damage detection strategies, and the continuous health assessment of concrete structures then become a matter of utmost importance. The ultimate goal of this research is to develop a nondestructive testing technique to quantify the amount of corrosion in the reinforcing steel. The guided mechanical wave approach has been explored towards the development of such methodology. The use of an embedded ultrasonic network for monitoring corrosion in real structures is feasible due to its simplicity. The ultrasonic waves, specifically cylindrical guided waves can p ropagate a long distance along the reinforcing steel bars and are found to be sensitive to the interface conditions between steel bars and concrete. Ultrasonic

  2. Reinforcement of concrete structures by fiberglass rods

    Directory of Open Access Journals (Sweden)

    Avdeeva Arina

    2016-01-01

    Full Text Available In this article we introduced conducted experiments to determine the basic characteristics of composite reinforcement fiberglass reinforcement on the example of the same diameter, but with a different number of rovings. We have established strength along the reinforcing fiber and the corresponding class of the steel reinforcement.

  3. Shear strength of non-shear reinforced concrete elements

    DEFF Research Database (Denmark)

    Hoang, Cao linh

    1997-01-01

    The report deals with the shear strength of statically indeterminate reinforced concrete beams without shear reinforcement. Solutions for a number of beams with different load and support conditions have been derived by means of the crack sliding model developed by Jin- Ping Zhang.This model...

  4. A New Type Anticorrosion Coating for Ocean Reinforced Concrete Structures

    Institute of Scientific and Technical Information of China (English)

    CHENG Qi; GENG Guisheng; LUO Feng; WU Sanyu; ZHAO Dalin

    2000-01-01

    Corrosion of reinforced concrete structures is a serious problem in ocean engineering. As an orientation of study, anticorrosion coating technique is developed and widely applied, but many problems need to be solved. LSW-2 type anticorrosion coating for maritime reinforced concrete structures is charac lerized by sea water resistance, salt fog resistance, moisture and heat resistance as well as impermeability to chlorions. The new type coating can be applied to wet concrete surface by conventional construction lechnique. It is a breakthrough in solving the above-mentioned problem. The paper mainly introduces the test results, the property indices, coating procedure, construction technique and economic benefit of the coating.

  5. Optimization Design and Application of Underground Reinforced Concrete Bifurcation Pipe

    Directory of Open Access Journals (Sweden)

    Chao Su

    2015-01-01

    Full Text Available Underground reinforced concrete bifurcation pipe is an important part of conveyance structure. During construction, the workload of excavation and concrete pouring can be significantly decreased according to optimized pipe structure, and the engineering quality can be improved. This paper presents an optimization mathematical model of underground reinforced concrete bifurcation pipe structure according to real working status of several common pipe structures from real cases. Then, an optimization design system was developed based on Particle Swarm Optimization algorithm. Furthermore, take the bifurcation pipe of one hydropower station as an example: optimization analysis was conducted, and accuracy and stability of the optimization design system were verified successfully.

  6. Design Basis for Fibre Reinforced Concrete (FRC) Pavements

    DEFF Research Database (Denmark)

    Bendixen, Søren; Stang, Henrik

    1996-01-01

    -crack opening relationship can beused to descibe the properties of fibre reinforced concrete (FRC) intension and how the stress-crack opening relationship can beapplied in a simple design scheme for pavements. The projectincludes development of design tools, experiments to determine thestress-crack opening......The paper summarises a Ph.D. project on development of a new design basis for fibre reinforced concrete ground slabs. The stress-crack openingrelationship is a well know basic material property of theso-called fictitious crack model for concrete. In the presentstudy it is shown how the stress...

  7. DAMAGE LOCATION DUE TO CORROSION IN REINFORCED CONCRETE STRUCTURES

    Institute of Scientific and Technical Information of China (English)

    WUJin; ChengJi-xin; LUMing-sheng

    2004-01-01

    An investigation on damage location due to the corrosion in reinforced concrete structures is conducted. The frequency change square ratio is used as a parameter for the damage. It is theoretically verified that the parameter is a function of the damage location. Experimental results of the corrosion in reinforced concrete structures show that the predicted damage location is in agreement with the real damage location. The modal parameters are used to detect the damages in structural concrete elements, and so they are useful for structural appraisal.

  8. Experiment and calculation of reinforced concrete at elevated temperatures

    CERN Document Server

    Guo, Zhenhai

    2011-01-01

    Concrete as a construction material goes through both physical and chemical changes under extreme elevated temperatures. As one of the most widely used building materials, it is important that both engineers and architects are able to understand and predict its behavior in under extreme heat conditions. Brief and readable, this book provides the tools and techniques to properly analysis the effects of high temperature of reinforced concrete which will lead to more stable, safer structures. Based on years of the author's research, Reinforced Concrete at Elevated Temperatures four par

  9. Diagonal Cracking and Shear Strength of Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Zhang, Jin-Ping

    1997-01-01

    found by the usual plastic theory, a physical explanation is given for this phenomenon and a way to estimate the shear capacity of reinforced concrete beams, based on the theory of plasticity, is described. The theoretical calculations are shown to be in fairly good agreement with test results from......The shear failure of non-shear-reinforced concrete beams with normal shear span ratios is observed to be governed in general by the formation of a critical diagonal crack. Under the hypothesis that the cracking of concrete introduces potential yield lines which may be more dangerous than the ones...

  10. Shear Capacity of Steel and Polymer Fibre Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Kragh-Poulsen, Jens C.; Hoang, Cao Linh; Goltermann, Per

    2011-01-01

    This paper deals with the application of a plasticity model for shear strength estimation of fibre reinforced concrete beams without stirrups. When using plastic theory to shear problems in structural concrete, the so-called effective strengths are introduced, usually determined by calibrating...... the plastic solutions with tests. This approach is, however, problematic when dealing with fibre reinforced concrete (FRC), as the effective strengths depend also on the type and the amount of fibres. In this paper, it is suggested that the effective tensile strength of FRC can be determined on the basis...

  11. Strengthening of dental adhesives via particle reinforcement.

    Science.gov (United States)

    Belli, Renan; Kreppel, Stefan; Petschelt, Anselm; Hornberger, Helga; Boccaccini, Aldo R; Lohbauer, Ulrich

    2014-09-01

    The bond between methacrylic polymer adhesives and dental restoratives is not perfect and may fail either in the short or in the long term. This study aims to evaluate the effects of particle incorporation in a self-etch model adhesive on mechanical and physical properties that are relevant during application and service. Filled adhesives containing 5, 10, 15 or 25wt% glass fillers were compared to their unfilled counterpart in terms of water sorption and solubility; viscosity and dynamic viscosity during polymerization were recorded using rheological measurements and compared to FTIR analysis of the real-time degree of cure. Elastic modulus and ultimate tensile strength measurements were performed in uniaxial tension; the energy to fracture was used to calculate the fracture toughness of the adhesives. Finally, the experimental adhesives were applied on dentin substrate to test the bond strength using the microtensile test. Results showed that the incorporation of 5-10wt% nanofiller to self-etching dental adhesives is efficient in accelerating the polymerization reaction and increasing the degree of cure without compromising the film viscosity for good wettability or water sorption and solubility. Fillers increased the elastic modulus, tensile strength and fracture toughness to a plateau between 5 and 15wt% filler concentration, and despite the tendency to form agglomerations, active crack pinning/deflection toughening mechanisms have been observed. The bond strength between resin composite and dentin was also improved when adhesives with up to 10wt% fillers were used, with no additional improvements with further packing. The use of fillers to reinforce dental adhesives may therefore be of great practical benefit by improving curing and mechanical properties. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Strength Evaluation of Steel-Nylon Hybrid Fibre Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Maniram Kumar

    2014-07-01

    Full Text Available When fibres like steel, glass, polypropylene, nylon, carbon, aramid, polyester, jute, etc are mixed with concrete known as fibre reinforced concrete. To overcome the deficiencies of concrete; fibres are added to improve the performance of concrete. In this research hybrid reinforced concrete is made by using steel and nylon 6 fibres. The inclusion of both steel and nylon 6 fibres are used in order to combine the benefits of both fibers; structural improvements provided by steel fibers and the resistance to plastic shrinkage improvements provided by nylon fibers. So the aim of this project is to investigate the mechanical properties (compressive strength, flexure strength and split tensile strength of hybrid fiber reinforced concrete under compression, flexure & tension. The total volume of fibre was taken 0.75 % of total volume of concrete. In this experimental work, four different concrete mix proportions were casted with fibres and one mix without fibres. Four different mix combinations of steel- nylon 6 fibres were 100-00%, 75-25%, 50-50% and 25-75%. Superplasticizer was used in all mixes to make concrete more workable. The results shown that compressive, split tensile and flexural strength of hybrid fibre reinforced concrete increase by increasing quantity of steel and nylon 6 fibres. The increase in compressive and tensile strength due to incorporation of steel fibre is greater than that of using nylon fibre. For the nylon 6 fibres, adding more fibres into the concrete has a limited improvement on splitting tensile strength. Inclusion of nylon 6 fibres along with steel fibres results in considerable improvement in flexural strength as compared to solo steel fibre.

  13. Inspection of reinforcement concrete structures with active infrared thermography

    Science.gov (United States)

    Szymanik, Barbara; Chady, Tomasz; Frankowski, Paweł

    2017-02-01

    In this article the reinforced concrete non-destructive evaluation using active thermography is discussed. There are several aspects of possible non-destructive testing of mentioned structures. One of them is the detection and assessment of the reinforcement itself. In case of active thermography, the external energy source has to be used to induce the thermal response of the inspected specimen. Here, authors propose two different techniques: microwave heating and induction heating. In this article authors will present several experimental results which will allow to compare mentioned two techniques of heating. suitability of each one to assess the reinforced concrete by using the active thermography will be discussed.

  14. Stochastic Models for Chloride-Initiated Corrosion in Reinforced Concrete

    DEFF Research Database (Denmark)

    Engelund, S.; Sørensen, John Dalsgaard

    1996-01-01

    Corrosion of the reinforcement in concrete structures can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is when the chloride content around the reinforcement exceeds a threshold value. In the present paper a statistical model is developed by which...... the chloride content in a reinforced concrete structure can be predicted. The model parameters are estimated on the basis of measurements. The distribution of the time to initiation of corrosion is estimated by FORM/SORM-analysis....

  15. Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Verma

    2014-01-01

    Full Text Available Corrosion of steel bars embedded in reinforced concrete (RC structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP method. This paper also presents few techniques to protect concrete from corrosion.

  16. Monitoring corrosion of steel bars in reinforced concrete structures.

    Science.gov (United States)

    Verma, Sanjeev Kumar; Bhadauria, Sudhir Singh; Akhtar, Saleem

    2014-01-01

    Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to present the importance of monitoring reinforcement corrosion and describes the different methods for evaluating the corrosion state of RC structures, especially hal-cell potential (HCP) method. This paper also presents few techniques to protect concrete from corrosion.

  17. IMPACT OF CHLORIDES ON REINFORCED CONCRETE: SIMULATION OF ITS INGRESS IN CONCRETE

    Directory of Open Access Journals (Sweden)

    S. Leonovich

    2012-01-01

    Full Text Available The paper presents a model for evaluation of environmental conditions that influence on reinforced highway structures. The models is applied for calculation of chloride ingress in concrete structures while using de-icing salt.

  18. IMPACT OF CHLORIDES ON REINFORCED CONCRETE: SIMULATION OF ITS INGRESS IN CONCRETE

    OpenAIRE

    S. Leonovich; A. Prasol

    2012-01-01

    The paper presents a model for evaluation of environmental conditions that influence on reinforced highway structures. The models is applied for calculation of chloride ingress in concrete structures while using de-icing salt.

  19. Behavior of Concrete Panels Reinforced with Synthetic Fibers, Mild Steel, and GFRP Composites Subjected to Blasts

    Energy Technology Data Exchange (ETDEWEB)

    C. P. Pantelides; T. T. Garfield; W. D. Richins; T. K. Larson; J. E. Blakeley

    2012-03-01

    The paper presents experimental data generated for calibrating finite element models to predict the performance of reinforced concrete panels with a wide range of construction details under blast loading. The specimens were 1.2 m square panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consisted of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bars; FRC panels without additional reinforcement; FRC panels with steel bars; NWC panels with glass fiber reinforced polymer (GFRP) bars; and NWC panels reinforced with steel bars and external GFRP laminates on both faces. Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. FRC panels with steel bars had the best performance for new construction. NWC panels reinforced with steel bars and external GFRP laminates on both faces had the best performance for strengthening or rehabilitation of existing structures. The performance of NWC panels with GFRP bars was strongly influenced by the bar spacing. The behavior of the panels is classified in terms of damage using immediate occupancy, life safety, and near collapse performance levels. Preliminary dynamic simulations are compared to the experimental results.

  20. Properties of Fiber Reinforced Polymer Concrete

    Directory of Open Access Journals (Sweden)

    Marinela Bărbuţă

    2008-01-01

    Full Text Available Polymer concrete is a composite material realized with resin and aggregates. In the present study the epoxy resin was used for binding the aggregates. In the composition were introduced near the fly ash, used as filler, the cellulose fibers. The mechanical characteristics such as compressive strength, flexural strength and split tensile strength of polymer concrete with fibers were investigated. The fiber percentage was constant, the epoxy resin and the filler dosages were varied. The cellulose fiber had not improved the mechanical characteristics of the polymer concrete in comparison to that of polymer concrete without cellulose fibers.

  1. STRAIN HARDENING PROPERTIES OF STEEL FIBRE REINFORCED LATEX CONCRETE COMPOSITE

    Directory of Open Access Journals (Sweden)

    V.M. Sounthararajan

    2013-04-01

    Full Text Available Steel fibre addition in concrete possesses high merits in terms of achieving homogeneity and tensile strength properties. Polymeric addition in concrete has high advantages in terms of pore fillingeffect and subsequent increase in durability index. The combined addition of steel and polymeric latex additions in concrete leads to increased strength, durability, toughness, resistance to cracking and crack propagation. Studies were conducted in the present study to analyse the properties of concrete that can be further improved with the addition of polymer styrene butadiene rubber emulsion (SBR along with steel fibres. In this research analysis, styrene-butadiene rubber (SBR latex as a polymeric admixture was used in steel fibre reinforced concrete. The effect of curing conditions on the strength gain properties of composite steel fibre latex matrix on the compressive, flexural strength, and split tensile test of polymermodified steel fibre reinforced concrete (PSFC concrete was examined. Including SBR latex at a certain % of binder in the PSFC concrete improves the bonds within the cement matrix and steel fibres (SF. This is due to the SBR films formed in the matrix. By the comparison of properties of SFC and PSFC, it can be shown that a tremendous increase in compressive strength when 4% and 8% SBR is added along with 0.75% and 1.5% SF. The increase in flexural strength was noticed and post cracking ductility is imparted to concrete.

  2. Experimental Study of the Flexural Behaviour of Damaged RC Beams Strengthened in Bending Moment Region with Basalt Fiber Reinforced Polymer (BFRP Sheets

    Directory of Open Access Journals (Sweden)

    Akshay P. Gholkar

    2014-07-01

    Full Text Available This paper presents the flexural behaviour of basalt fiber reinforced polymer (BFRP strengthened reinforced concrete (RC beams. For flexural strengthening of reinforced concrete beams, total twenty-two beams were cast and tested over an effective span of 900 mm up to failure of the beam under two-point loading. The beams were designed as under-reinforced beams. The beams were bonded with BFRP sheets in single layer and double layers in the bending moment region at the bottom face of the beam. Out of the twenty-two beams two beams were control beams and remaining beams were strengthened after being damaged for various degrees of damage (0 %, 70 %, 80 %, 90% and 100 %. The experimental results show that the beams strengthened show high load carrying capacity.

  3. Acoustic emission characteristics on microscopic damage behavior of carbon fiber sheet reinforced concrete

    Science.gov (United States)

    Lee, Jin Kyung; Lee, Joon Hyun

    2002-05-01

    In this study, a three-point bend test has been carried out to understand the damage progress and the micro-failure mechanism of carbon fiber sheet (CFS) reinforced concretes. For these purposes, four kinds of specimens were used; unreinforced concrete, steel bar reinforced concrete, CFS reinforced concrete, and concrete reinforced by both steel bar and CFS. Acoustic Emission (AE) technique was used to evaluate the characteristics of damage progress and the failure mechanism of the specimens.

  4. Corrosion inhibiting repair and rehabilitation treatment process for reinforced concrete structures

    OpenAIRE

    1994-01-01

    A repair and rehabilitation treatment process for reinforced concrete structures involves the removal of concrete from above rebar or other metal reinforcement material in the concrete structure. After removal of concrete, the metal reinforcement materials are saturated with corrosion inhibiting agents. Saturation is best achieved by multiple spray applications of the corrosion inhibitor. The cavity in the concrete structure with the treated rebar or other metal reinforcement materials is the...

  5. STUDIES OF DURABILITY ASPECTS OF FIBRE REINFORCED CONCRETE

    Directory of Open Access Journals (Sweden)

    D. MARUTHACHALAM

    2012-02-01

    Full Text Available This paper presents a detailed experimental study on sulphate attack, depth of carbonation, alkalinity measurement on fibre reinforced concrete at ages 28 days, 56 days, and 90 days. The main variable investigated in this study is variation of fibre dosage of 0.1%, 0.2%, and 0.3%. The concrete produced by the addition of fly ash and metakaolin as a partial replacement of cement. The compressive strength, weight loss and hardness of concrete were studied. Test results indicate that use of fibre in concrete has improved performance of concrete. A simple regression equation has been proposed to study the behaviour of concrete under sulphate attack, depth of carbonation.

  6. Structural Behavior of Concrete Beams Reinforced with Basalt Fiber Reinforced Polymer (BFRP) Bars

    Science.gov (United States)

    Ovitigala, Thilan

    The main challenge for civil engineers is to provide sustainable, environmentally friendly and financially feasible structures to the society. Finding new materials such as fiber reinforced polymer (FRP) material that can fulfill the above requirements is a must. FRP material was expensive and it was limited to niche markets such as space shuttles and air industry in the 1960s. Over the time, it became cheaper and spread to other industries such as sporting goods in the 1980-1990, and then towards the infrastructure industry. Design and construction guidelines are available for carbon fiber reinforced polymer (CFRP), aramid fiber reinforced polymer (AFRP) and glass fiber reinforced polymer (GFRP) and they are currently used in structural applications. Since FRP is linear elastic brittle material, design guidelines for the steel reinforcement are not valid for FRP materials. Corrosion of steel reinforcement affects the durability of the concrete structures. FRP reinforcement is identified as an alternative to steel reinforcement in corrosive environments. Although basalt fiber reinforced polymer (BFRP) has many advantages over other FRP materials, but limited studies have been done. These studies didn't include larger BFRP bar diameters that are mostly used in practice. Therefore, larger beam sizes with larger BFRP reinforcement bar diameters are needed to investigate the flexural and shear behavior of BFRP reinforced concrete beams. Also, shear behavior of BFRP reinforced concrete beams was not yet studied. Experimental testing of mechanical properties and bond strength of BFRP bars and flexural and shear behavior of BFRP reinforced concrete beams are needed to include BFRP reinforcement bars in the design codes. This study mainly focuses on the use of BFRP bars as internal reinforcement. The test results of the mechanical properties of BFRP reinforcement bars, the bond strength of BFRP reinforcement bars, and the flexural and shear behavior of concrete beams

  7. Shear Strengthening of Corbels with Carbon Fibre Reinforced Polymers (CFRP

    Directory of Open Access Journals (Sweden)

    Nawaz, A.

    2010-09-01

    Full Text Available Corbels constitute what are known as “disturbed” regions in concrete structures, where typical shear failure may be anticipated on the grounds of small shear span-to-depth ratios. The concentration of stress induced by the weight of girders on the very small loadbearing areas in corbels often causes cracking in bridges and other structures. Little experimental research can be found in the literature on the shear strengthening of corbels. In the present study, nine such members were tested. Two had no carbon fibre reinforced polymers attached, while CFRP laminates were externally bonded to the other seven, in a number of different spatial arrangements. Ultimate shear strength was found and compared for all specimens. The results showed that CFRP configuration and geometry directly affected corbel shear strength, which was higher in all the CFRPstrengthened corbels than in the controls. The highest strength values were recorded for specimens whose shear-critical area was wrapped in CFRP.

    Las ménsulas constituyen lo que conocemos como regiones de “distorsión” en las estructuras de hormigón, zonas en que pueden preverse roturas por cortante debido a las bajas relaciones luz de cortante-canto presentes en ellas. La concentración de solicitaciones producida por el peso de las vigas sobre superficies de carga muy reducidas en las ménsulas a menudo provoca el agrietamiento de puentes y otras estructuras de obra civil. En la literatura especializada sobre el refuerzo a cortante de las ménsulas existen escasos ejemplos de estudios experimentales. Para la presente investigación se han realizado ensayos con nueve elementos de este tipo. Dos de ellos no incluían polímeros reforzados con fibra de carbono (CFRP, mientras que los siete restantes llevaban láminas externas de CFRP, dispuestas siguiendo distintas configuraciones espaciales. Los resultados indican que la configuración y la disposición geométrica de los CFRP repercuten

  8. Behavior and Performance of GFRP Reinforced Concrete Columns with Various Types of Stirrups

    OpenAIRE

    Woraphot Prachasaree; Sitthichai Piriyakootorn; Athawit Sangsrijun; Suchart Limkatanyu

    2015-01-01

    Fiber reinforced polymer (FRP) composites are gaining acceptance in concrete structural applications due to their high ratio of strength/stiffness to self-weight and corrosion resistance. This study focused on the structural behavior and the performance of concrete columns internally reinforced with glass fiber reinforced plastic (GFRP) rebars. Twelve series of concrete columns with varied longitudinal reinforcement, cross section, concrete cover, and type of lateral reinforcement were tested...

  9. Evaluating plastic shrinkage and permeability of polypropylene fiber reinforced concrete

    Directory of Open Access Journals (Sweden)

    G.M. Sadiqul Islam

    2016-12-01

    Full Text Available Plastic concrete is susceptible to develop cracks due to shrinkage in dry and windy conditions. Addition of fibers could reduce propagation of this crack. On the other hand, permeability determines the durability properties of concrete. This study evaluated strength, plastic shrinkage and permeability (gas and water of concrete incorporating ‘polypropylene’ fiber (aspect ratio 300 in various proportions (viz. 0.10%, 0.15%, 0.2%, 0.25% and 0.3% by volume of concrete. Plane concrete samples were also prepared and tested for reference purpose. Inclusion of 0.1% fiber gave minor reduction (2% in compressive strength while the tensile strength increased by 39% with same fiber content compared to the plain concrete. A significant reduction in crack generation, appearance period of first crack and crack area between plane concrete and fiber reinforced concretes was found. The experimental result with inclusion of 0.1–0.3% fiber in concrete indicated that plastic shrinkage cracks were reduced by 50–99% compared to the plain concrete. For reference concrete (without fiber, test within the high temperature and controlled humidity chamber gave higher crack width than the acceptable limit (3 mm specified by the ACI 224. With the inclusion of 0.1% fiber reduced the crack width down to 1 mm and the trend was continued with the addition of more fibers. However, results showed that with the addition of polypropylene fiber both water and gas permeability coefficient was increased. Therefore, it is concluded that the fiber reinforced concrete would work better for plastic shrinkage susceptible structural elements (flat elements such as slab; however, it requires careful judgement while applying to a water retaining structures.

  10. In-plane shear test of fibre reinforced concrete panels

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe; Stang, Henrik; Goltermann, Per

    2008-01-01

    contributes to the investigation of fibers as reinforcement in panels with experimental results and a consistent approach to material characterization and modeling. The proposed model draws on elements from the classical yield line theory of rigid, perfectly plastic materials and the theory of fracture......The present paper concerns the investigation of polymer Fiber Reinforced Concrete (FRC) panels subjected to in-plane shear. The use of fibers as primary reinforcement in panels is a new application of fiber reinforcement, hence test methods, design bases and models are lacking. This paper...

  11. Application of a Reinforced Self-Compacting Concrete Jacket in Damaged Reinforced Concrete Beams under Monotonic and Repeated Loading

    Directory of Open Access Journals (Sweden)

    Constantin E. Chalioris

    2013-01-01

    Full Text Available This paper presents the findings of an experimental study on the application of a reinforced self-compacting concrete jacketing technique in damaged reinforced concrete beams. Test results of 12 specimens subjected to monotonic loading up to failure or under repeated loading steps prior to total failure are included. First, 6 beams were designed to be shear dominated, constructed by commonly used concrete, were initially tested, damaged, and failed in a brittle manner. Afterwards, the shear-damaged beams were retrofitted using a self-compacting concrete U-formed jacket that consisted of small diameter steel bars and U-formed stirrups in order to increase their shear resistance and potentially to alter their initially observed shear response to a more ductile one. The jacketed beams were retested under the same loading. Test results indicated that the application of reinforced self-compacting concrete jacketing in damaged reinforced concrete beams is a promising rehabilitation technique. All the jacketed beams showed enhanced overall structural response and 35% to 50% increased load bearing capacities. The ultimate shear load of the jacketed beams varied from 39.7 to 42.0 kN, whereas the capacity of the original beams was approximately 30% lower. Further, all the retrofitted specimens exhibited typical flexural response with high values of deflection ductility.

  12. Crack widths in concrete with fibers and main reinforcement

    DEFF Research Database (Denmark)

    Christensen, Frede; Ulfkjær, Jens Peder; Brincker, Rune

    the ductility of the fiber reinforced concrete (FRC) is set up and experimental work is conducted in order to verify the crack width model. The ductility of the FRC is taken into account by using the stress crack width relation. The constitutive model for the FRC is based on the idea that the initial part......The main object of the research work presented in this paper is to establish design tools for concrete structures where main reinforcement is combined with addition of short discrete steel fibers. The work is concerned with calculating and measuring crack widths in structural elements subjected...... to bending load. Thus, the aim of the work is to enable engineers to calculate crack widths for flexural concrete members and analyze how different combinations of amounts of fibers and amounts of main reinforcement can meet a given maximum crack width requirement. A mathematical model including...

  13. Analysis of cracking in reinforced concrete using accelerated tests

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Q.T.; Berthaud, Y. [Univ Paris 06, CNRS, ENSC, LMT, F-94235 Cachan (France); Care, S [CNRS, ENPC, LCPC, Inst Navier, LMSGC, F-77420 Champs Sur Marne (France); Millard, A. [CEA, DEN/DM2S/SEMT/LM2S, F-91191 Gif Sur Yvette (France)

    2007-02-15

    We present in this Note an experimental study-in a laboratory setup-of the mechanical effect (cracking of concrete) of corrosion on plates made of reinforced concrete. Due to the geometry it is possible to use digital image correlation to follow the evolution of strains induced by the corrosion of reinforcement. The corrosion is accelerated by the imposition of current density. Even if the representativeness of this test is still discussed, it allows one to record the entire strain history. The kinetics of cracking has been obtained and compared to a very simple model in which the increase of the corroded layer is modelled by a fictitious thermal load, the reinforcement remaining elastic and the concrete being damageable. (authors)

  14. Dynamic behavior of reinforced concrete frame structure during construction

    Institute of Scientific and Technical Information of China (English)

    TIAN Ming-ge; YI Wei-jian

    2008-01-01

    The effects of concrete's time-variant elastic modulus, casting structural components, assembling temporary shoring framework system, and shock by operating construction equipment on dynamic behavior of the reinforced concrete frame structure during construction were investigated. The dynamic tests of an eight-storey reinforced concrete frame structure during full-scaled stages of the sixth storey construction cycle were carried out by ambient vibration. Natural frequencies, corresponding mode shapes and damping ratio were determined by power spectrum processing the tested signal data in frequency domain. The changes of frequencies, mode shapes and damping ratios at different construction stages were given. The results show that natural frequencies and modal damping ratios reach the maximum at stage of casting fresh concrete, especially for higher modes. Modal damping ratios at each construction stage are less than 5% of those during usage.

  15. Flexural Strength and Behavior of Polypropylene Fiber Reinforced Concrete Beams

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The strength and deformation characteristics of polypropylene fiber reinforced concrete (PFRC) beams were investigated by four-point bending procedures in this paper.Two kinds of polypropylene fibers with different fiber contents (0.2%, 0.5%, 1.0% and 1.5%) by volume were used in the beam, which measured 100×100 mm with a span of 300 mm.It was found that the strength of the reinforced concrete beams was significantly decreased,whereas the flexural toughness was improved,compared to those unreinforced concrete beams.Geometry properties and volume contents of polypropylene fiber were considered to be important factors for improving the flexural toughness.Moreover,the composite mechanism between polypropylene fiber and concrete was analyzed and discussed.

  16. Simulation analysis of impact tests of steel plate reinforced concrete and reinforced concrete slabs against aircraft impact and its validation with experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Sadiq, Muhammad, E-mail: muhammad.sadiq@pnra.org [Center for Nuclear Safety (CNS), Pakistan Nuclear Regulatory Authority (PNRA), PO Box 1912, Islamabad (Pakistan); Xiu Yun, Zhu, E-mail: lyzhuxiuyun@163.com [Nuclear and Radiation Safety Center (NSC), Ministry of Environmental Protection (MEP), Beijing (China); Rong, Pan, E-mail: panrong@chinansc.cn [Nuclear and Radiation Safety Center (NSC), Ministry of Environmental Protection (MEP), Beijing (China)

    2014-07-01

    Highlights: • Simulation analysis is carried out with two constitutive concrete models. • Winfrith model can better simulate nonlinear response of concrete than CSCM model. • Performance of steel plate concrete is better than reinforced concrete. • Thickness of safety related structures can be reduced by adopting steel plates. • Analysis results, mainly concrete material models should be validated. - Abstract: The steel plate reinforced concrete and reinforced concrete structures are used in nuclear power plants for protection against impact of an aircraft. In order to compare the impact resistance performance of steel plate reinforced concrete and reinforced concrete slabs panels, simulation analysis of 1/7.5 scale model impact tests is carried out by using finite element code ANSYS/LS-DYNA. The damage modes of all finite element models, velocity time history curves of the aircraft engine and damage to aircraft model are compared with the impact test results of steel plate reinforced concrete and reinforced concrete slab panels. The results indicate that finite element simulation results correlate well with the experimental results especially for constitutive winfrith concrete model. Also, the impact resistance performance of steel plate reinforced concrete slab panels is better than reinforced concrete slab panels, particularly the rear face steel plate is very effective in preventing the perforation and scabbing of concrete than conventional reinforced concrete structures. In this way, the thickness of steel plate reinforced concrete structures can be reduced in important structures like nuclear power plants against impact of aircraft. It also demonstrates the methodology to validate the analysis procedure with experimental and analytical studies. It may be effectively employed to predict the precise response of safety related structures against aircraft impact.

  17. Performance and Durability Evaluation of Bamboo Reinforced Cement Concrete Beams

    Directory of Open Access Journals (Sweden)

    Ankit Singh Mehra

    2016-04-01

    Full Text Available A big part of population in India is still homeless due to raising unaffordability of housing structures. People sleeping on roadsides and living in slums is a common sight in Indian cities. To overcome this problem India today needs millions of houses for their growing population, making concrete as the most widely to be used material in the country. Concrete has found to have excellent compressive strength but poor in tensile strength, to take care of the tensile stresses steel is commonly used as reinforcing material in concrete. Production of steel is a very costly business and its use in concrete as reinforcing material increases the cost of construction by many folds. Also production of steel emits a large amount of green house gases causing considerable deterioration of the environment. The above mentioned socio-economic and environmental factors creates a necessity for finding an appropriate environment friendly and cheap material that can successfully substitute steel as reinforcement in concrete elements of a low cost dwelling for the poor and homeless people of the country. It is here that engineered bamboo can be of great value to Civil Engineers owning to its several net worthy features. Production of every tone of bamboo consumes about a tone of atmospheric CO2 in addition to releasing fresh O2. From structural point of view bamboo has been used as a structural material from the earlier times as it possesses excellent flexure and tensile strength as well as high strength to weight ratio. All this necessitates examining bamboo-reinforced cement concrete in detail for its appropriateness as a structural material for construction of a low cost dwelling unit. The study focuses on evaluating the mechanical and durability properties of cement-concrete beams both singly and doubly reinforced with bamboo splints.

  18. Evaluation of size dependent design shear strength of reinforced concrete beams without web reinforcement

    Indian Academy of Sciences (India)

    G Appa Rao; S S Injaganeri

    2011-06-01

    Analytical studies on the effect of depth of beam and several parameters on the shear strength of reinforced concrete beams are reported. A large data base available has been segregated and a nonlinear regression analysis (NLRA) has been performed for developing the refined design models for both, the cracking and the ultimate shear strengths of reinforced concrete (RC) beams without web reinforcement. The shear strength of RC beams is size dependent, which needs to be evaluated and incorporated in the appropriate size effect models. The proposed models are functions of compressive strength of concrete, percentage of flexural reinforcement and depth of beam. The structural brittleness of large size beams seems to be severe compared with highly ductile small size beams at a given quantity of flexural reinforcement. The proposed models have been validated with the existing popular models as well as with the design code provisions.

  19. Crack Identification in Reinforced Concrete Beams Using Ansys Software

    OpenAIRE

    2014-01-01

    Analytical determination of displacements and stresses in reinforced concrete material was difficult task and engineers had to rely on empirical formulas because concrete consists of heterogeneous material and creep and shrinkage influenced deformations in it. Due to these complexities engineers in past had been facing difficulties in coping such problems, but with the advancement of digital computerization and modern numerical methods for analysis such as finite element metho...

  20. An Incursion on Punching of Reinforced Concrete Flat Slabs

    OpenAIRE

    2009-01-01

    Starting from the early 60s continuous studies have been made regarding punching of concrete flat slabs. The evolution of technology and calculus systems influenced this engineering branch. Nowadays is possible to account in structural analysis all the non-linear behaviour of reinforced and prestressed concrete and to get the most close structural response in comparison with the real behaviour. As a controversy matter, several tests and theories have been developed. Nowadays researchers try t...

  1. The Experimental Study of Concrete Beams Reinforced with Different Types of Bars Carrying Capacity

    OpenAIRE

    Benin Andrey; Semenov Sergey; Ekaterina Bogdanova

    2016-01-01

    The results of experimental study on concrete beams reinforced with glass fiber reinforced plastic (GFRP) bars are presented and compared with steel reinforced concrete beams and beams reinforced with steel and GFRP bars together. Three series of reinforced beams were tested in the flexure. The experimental data are showed that possible area in which GFRP bar possesses potential to employ is secondary reinforcement in concrete structures.

  2. The Experimental Study of Concrete Beams Reinforced with Different Types of Bars Carrying Capacity

    Directory of Open Access Journals (Sweden)

    Benin Andrey

    2016-01-01

    Full Text Available The results of experimental study on concrete beams reinforced with glass fiber reinforced plastic (GFRP bars are presented and compared with steel reinforced concrete beams and beams reinforced with steel and GFRP bars together. Three series of reinforced beams were tested in the flexure. The experimental data are showed that possible area in which GFRP bar possesses potential to employ is secondary reinforcement in concrete structures.

  3. Computational Homogenization of Fresh Concrete Flow Around Reinforcing Bars

    CERN Document Server

    Kolařík, Filip; Zeman, Jan

    2016-01-01

    Motivated by casting of fresh concrete in reinforced concrete structures, we introduce a numerical model of a steady-state non-Newtonian fluid flow through a porous domain. Our approach combines homogenization techniques to represent the reinforced domain by the Darcy law with an interface coupling of the Stokes and Darcy flows through the Beavers-Joseph-Saffman conditions. The ensuing two-scale problem is solved by the Finite Element Method with consistent linearization and the results obtained from the homogenization approach are verified against fully resolved direct numerical simulations.

  4. Observations on the electrical resistivity of steel fibre reinforced concrete

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe; Geiker, Mette Rica; Edvardsen, Carola;

    2014-01-01

    Steel fibre reinforced concrete (SFRC) is in many ways a well-known construction material, and its use has gradually increased over the last decades. The mechanical properties of SFRC are well described based on the theories of fracture mechanics. However, knowledge on other material properties......, including the electrical resistivity, is sparse. Among others, the electrical resistivity of concrete has an effect on the corrosion process of possible embedded bar reinforcement and transfer of stray current. The present paper provides experimental results concerning the influence of the fibre volume...

  5. Performance based design of reinforced concrete beams under impact

    Directory of Open Access Journals (Sweden)

    S. Tachibana

    2010-06-01

    Full Text Available The purpose of this research is to collect fundamental data and to establish a performance-based design method for reinforced concrete beams under perpendicular impact load.

    Series of low speed impact experiments using reinforced concrete beams were performed varying span length, cross section and main reinforcement.

    The experimental results are evaluated focusing on the impact load characteristics and the impact behaviours of reinforced concrete beams. Various characteristic values and their relationships are investigated such as the collision energy, the impact force duration, the energy absorbed by the beams and the beam response values. Also the bending performance of the reinforced concrete beams against perpendicular impact is evaluated.

    An equation is proposed to estimate the maximum displacement of the beam based on the collision energy and the static ultimate bending strength. The validity of the proposed equation is confirmed by comparison with experimental results obtained by other researchers as well as numerical results obtained by FEM simulations. The proposed equation allows for a performance based design of the structure accounting for the actual deformation due to the expected impact action.

  6. An Incursion on Punching of Reinforced Concrete Flat Slabs

    Directory of Open Access Journals (Sweden)

    Dan-Vasile Bompa

    2009-01-01

    Full Text Available Starting from the early 60s continuous studies have been made regarding punching of concrete flat slabs. The evolution of technology and calculus systems influenced this engineering branch. Nowadays is possible to account in structural analysis all the non-linear behaviour of reinforced and prestressed concrete and to get the most close structural response in comparison with the real behaviour. As a controversy matter, several tests and theories have been developed. Nowadays researchers try to find the most accurate and economic formula for punching. This paper purpose is to make a survey on punching classical model and related nonlinear concrete behaviour regarded to this issue.

  7. Durability of cracked fibre reinforced concrete structures exposed to chlorides

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place; Ekman, Tom; Hansen, Kurt Kielsgaard

    1999-01-01

    is used as environmental load. The chloride penetration is characterized both qualitatively (UV-test) and quantitatively (chloride profile) and by microscopy. The test programme involves three different concrete qualities. Both steel fibres and polypropylene fibres are used in the concrete beams as well......Durability studies are carried out by subjecting FRC-beams to combined mechanical and environmental load. Mechanical load is obtained by exposing beams to 4-point bending until a predefined crack width is reached, using a newly developed test setup. Exposure to a concentrated chloride solution...... as main reinforcement. The effect of the cracks, the fibres and the concrete quality on the chloride penetration is studied....

  8. Concrete cover cracking with localized corrosion of reinforcing steel

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Acosta, A. A.; Sagues, A. A. [South Florida Univ., Dept of Civil and Environmental Engineering, Tampa FL (United States)

    2000-07-01

    The critical amount of steel corrosion needed for concrete cover cracking of a reinforced concrete element was measured, focusing on cases where only a fraction of the steel bar length is corroding. The amount of corrosion needed to crack the concrete cover was found to range between 49 micrometre to 137 micrometre in specimens of localized corrosion. In contrast, in cases of uniform corrosion of comparable systems the corrosion needed to crack the concrete cover varied from 15 micrometre to 75 micrometer. Based on this and previous work on this problem, an empirical equation is proposed for the critical amount of steel corrosion as a function of specimen dimensions. The model proposed for estimating the critical amount of steel corrosion showed reasonable agreement between estimates of the work of corrosion expansion and the energy required to crack the concrete. 23 refs., 3 tabs., 8 figs.

  9. Numerical modelling of reinforced concrete beams with fracture-plastic material

    Directory of Open Access Journals (Sweden)

    O. Sucharda

    2014-10-01

    Full Text Available This paper describes the use of models of fracture-plastic materials for reinforced concrete in numerical modelling of beams made from reinforced concrete. The purpose of the paper is to use of a model of concrete for modelling of a behaviour of reinforced concrete beams which have been tested at the University of Toronto within re-examination of classic concrete beam tests. The original tests were performed by Bresler- Scordelis. A stochastic modelling based on LHS (Latin Hypercube Sampling has been performed for the reinforced concrete beam. An objective of the modelling is to evaluate the total bearing capacity of the reinforced concrete beams depending on distribution of input data. The beams from the studied set have longitudinal reinforcement only. The beams do not have any shear reinforcement. The software used for the fracture-plastic model of the reinforced concrete is the ATENA.

  10. Durability of cracked fibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place; Nielsen, Laila

    1997-01-01

    (capillary water uptake) is used, involving an in-situ method and a laboratory method. Three different concrete qualities as well as steel fibres (ZP) and polypropylene fibres (PP) are used. Results of the durability tests on cracked FRC-beams are compared to results for uncracked FRC-beams and beams without...

  11. Stochastic Modeling of Reinforced Concrete Structures Exposed to Chloride Attack

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Frier, Christian

    2003-01-01

    concentration and reinforcement cover depth are modeled by stochastic fields. The paper contains a description of the parameters to be included in a stochastic model and a proposal for the information needed to obtain values for the parameters in order to be ab le to perform reliability investigations...... the reinforcement exceeds a critical threshold value. In the present paper a stochastic model is described by which the chloride content in a reinforced concrete structure can be estimated. The chloride ingress is modeled by a 2-dimensional diffusion process and the diffusion coefficient, surface chloride...

  12. Report on aging of nuclear power plant reinforced concrete structures

    Energy Technology Data Exchange (ETDEWEB)

    Naus, D.J.; Oland, C.B. [Oak Ridge National Lab., TN (United States); Ellingwood, B.R. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Civil Engineering

    1996-03-01

    The Structural Aging Program provides the US Nuclear Regulatory Commission with potential structural safety issues and acceptance criteria for use in continued service assessments of nuclear power plant safety-related concrete structures. The program was organized under four task areas: Program Management, Materials Property Data Base, Structural Component Assessment/Repair Technology, and Quantitative Methodology for Continued Service Determinations. Under these tasks, over 90 papers and reports were prepared addressing pertinent aspects associated with aging management of nuclear power plant reinforced concrete structures. Contained in this report is a summary of program results in the form of information related to longevity of nuclear power plant reinforced concrete structures, a Structural Materials Information Center presenting data and information on the time variation of concrete materials under the influence of environmental stressors and aging factors, in-service inspection and condition assessments techniques, repair materials and methods, evaluation of nuclear power plant reinforced concrete structures, and a reliability-based methodology for current and future condition assessments. Recommendations for future activities are also provided. 308 refs., 61 figs., 50 tabs.

  13. Ultimate deformation capacity of reinforced concrete slabs underblast load

    NARCIS (Netherlands)

    Doormaal, J.C.A.M. van; Weerheijm, J.

    1996-01-01

    In this paper a test method to determine the deformation capacity and the resistance-deformation curve of blast-loaded slabs is described. This method was developed at TNO-PML. The method has been used to determine the ultimate deformation capacity of some simply supported reinforced concrete slabs

  14. Comparison of two novel approaches to model fibre reinforced concrete

    NARCIS (Netherlands)

    Radtke, F.K.F.; Simone, A.; Sluys, L.J.

    2009-01-01

    We present two approaches to model fibre reinforced concrete. In both approaches, discrete fibre distributions and the behaviour of the fibre-matrix interface are explicitly considered. One approach employs the reaction forces from fibre to matrix while the other is based on the partition of unity f

  15. Service Life and Maintenance Modelling of Reinforced Concrete Bridge Decks

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    Recent research in the area of assessment and maintenance of reinforced concrete bridge decks is presented in this paper. Three definitions of service lifetime are introduced and the difficult problem of assessing the service life is discussed. A stochastic modelling of corrosion and corrosion...

  16. Limit Analysis of 3D Reinforced Concrete Beam Elements

    DEFF Research Database (Denmark)

    Larsen, Kasper P.; Nielsen, Leif Otto; Poulsen, Peter Noe

    2012-01-01

    A new finite-element framework for lower-bound limit analysis of reinforced concrete beams, subjected to loading in three dimensions, is presented. The method circumvents the need for a direct formulation of a complex section-force-based yield criterion by creating a discrete representation of th...

  17. Stress wave propagation in reinforced concrete piles during driving

    NARCIS (Netherlands)

    Zorn, N.F.

    1983-01-01

    The aim of this report is to give an insight into what happens in a reinforced concrete pile during driving, and to contribute to design requirements for the loading case pile driving. Since the behaviour of stress waves in piles is influenced by a various number of parameters, the fewest of which r

  18. Optimisation of the Crack Pattern in Continuously Reinforced Concrete Pavements

    NARCIS (Netherlands)

    Ren, D.

    2015-01-01

    Recent field investigations on several new Continuously Reinforced Concrete Pavements (CRCP) in Belgium indicate that its crack pattern is characterized by low mean crack spacing along with a high percentage of clusters of closely spaced cracks. Field surveys also indicate that it is difficult to si

  19. Stress wave propagation in reinforced concrete piles during driving

    NARCIS (Netherlands)

    Zorn, N.F.

    1983-01-01

    The aim of this report is to give an insight into what happens in a reinforced concrete pile during driving, and to contribute to design requirements for the loading case pile driving. Since the behaviour of stress waves in piles is influenced by a various number of parameters, the fewest of which

  20. Optimisation of the Crack Pattern in Continuously Reinforced Concrete Pavements

    NARCIS (Netherlands)

    Ren, D.

    2015-01-01

    Recent field investigations on several new Continuously Reinforced Concrete Pavements (CRCP) in Belgium indicate that its crack pattern is characterized by low mean crack spacing along with a high percentage of clusters of closely spaced cracks. Field surveys also indicate that it is difficult to si

  1. Bending Resistance of Steel Plate-Reinforced Concrete Beam

    Institute of Scientific and Technical Information of China (English)

    TIAN Zhimin; CHEN Jie

    2006-01-01

    The formulas for calculating bending-resistant capacity of a steel plate-reinforced concrete composite beam are derived.To validate the formulas,experiments of the composite beam under three-point bending are carried out.Calculated results based on the formulas are in good agreement with experimental results.

  2. Dynamic Elasto-Plastic Model for Reinforced Concrete Members

    NARCIS (Netherlands)

    Van der Veen, C.; Blaauwendraad. J.

    1983-01-01

    It is becoming increasingly necessary to investigate the strength of reinforced concrete structures subjected to dynamic loading. Experience and knowledge relating to the non-linear dynamic behaviour of such structures is still limited, however. Attempts to solve this type of problems with the aid o

  3. Applicability Problem in Optimum Reinforced Concrete Structures Design

    Directory of Open Access Journals (Sweden)

    Ashara Assedeq

    2016-01-01

    Full Text Available Optimum reinforced concrete structures design is very complex problem, not only considering exactness of calculus but also because of questionable applicability of existing methods in practice. This paper presents the main theoretical mathematical and physical features of the problem formulation as well as the review and analysis of existing methods and solutions considering their exactness and applicability.

  4. Performance of steel-making slag concrete reinforced with fibers

    Directory of Open Access Journals (Sweden)

    Ortega-López Vanesa

    2017-01-01

    Full Text Available In this research, the possibility of making concrete reinforced with fibers and manufactured with recycled aggregates from carbon steel production was explored. Electric arc furnace slag (EAFS was used as coarse and medium aggregate, and part of the sand sizes. Metallic and synthetic fibers were added in different amounts. Initially, the properties of EAFS and their suitability to be used in the manufacture fiber reinforced concrete were analysed. Then, a series of fiber reinforced concrete mixtures were developed incorporating EAFS, and they were compared with the reference mixtures, made with conventional components plus fibers and made with EAFS without fibers. A series of tests were performed, including concepts such as consistency, compressive strength, flexural strength, splitting tensile strength, resistance to water penetration or toughness. The results show that it is possible to make a suitable steel-slag concrete reinforced with fibers, complying with the standard requirements for it use in pavements and slab, and improving their proprieties respect to the control mixtures.

  5. Probabilistic Fatigue Model for Reinforced Concrete Onshore Wind Turbine Foundations

    DEFF Research Database (Denmark)

    Marquez-Dominguez, Sergio; Sørensen, John Dalsgaard

    2013-01-01

    Reinforced Concrete Slab Foundation (RCSF) is the most common onshore wind turbine foundation type installed by the wind industry around the world. Fatigue cracks in a RCSF are an important issue to be considered by the designers. Causes and consequences of the cracks due to fatigue damage in RCSFs...

  6. Probabilistic Fatigue Model for Reinforced Concrete Onshore Wind Turbine Foundations

    DEFF Research Database (Denmark)

    Marquez-Dominguez, Sergio; Sørensen, John Dalsgaard

    2013-01-01

    Reinforced Concrete Slab Foundation (RCSF) is the most common onshore wind turbine foundation type installed by the wind industry around the world. Fatigue cracks in a RCSF are an important issue to be considered by the designers. Causes and consequences of the cracks due to fatigue damage in RCSFs...

  7. Optimisation of the Crack Pattern in Continuously Reinforced Concrete Pavements

    NARCIS (Netherlands)

    Ren, D.

    2015-01-01

    Recent field investigations on several new Continuously Reinforced Concrete Pavements (CRCP) in Belgium indicate that its crack pattern is characterized by low mean crack spacing along with a high percentage of clusters of closely spaced cracks. Field surveys also indicate that it is difficult to

  8. Rigid-plastic seismic design of reinforced concrete structures

    DEFF Research Database (Denmark)

    Costa, Joao Domingues; Bento, R.; Levtchitch, V.

    2007-01-01

    In this paper a new seismic design procedure for Reinforced Concrete (R/C) structures is proposed-the Rigid-Plastic Seismic Design (RPSD) method. This is a design procedure based on Non-Linear Time-History Analysis (NLTHA) for systems expected to perform in the non-linear range during a lifetime...

  9. Aspects of Robust Computational Modeling for Plain and Reinforced Concrete

    NARCIS (Netherlands)

    Feenstra, F.H.; De Borst, R.

    1993-01-01

    The problems commonly encountered in the numerical analysis of reinforced structures are often related to biaxial stress states in the structure. In this study this problem is solved with the formulation of a composite plasticity model which describes both cracking and crushing of concrete within th

  10. Ultimate deformation capacity of reinforced concrete slabs underblast load

    NARCIS (Netherlands)

    Doormaal, J.C.A.M. van; Weerheijm, J.

    1996-01-01

    In this paper a test method to determine the deformation capacity and the resistance-deformation curve of blast-loaded slabs is described. This method was developed at TNO-PML. The method has been used to determine the ultimate deformation capacity of some simply supported reinforced concrete slabs

  11. Axial compression behavior of concrete masonry wallettes strengthened with cement mortar overlays

    Directory of Open Access Journals (Sweden)

    F. L. De Oliveira

    Full Text Available This paper presents the results of a series of axial compression tests on concrete block wallettes coated with cement mortar overlays. Different types of mortars and combinations with steel welded meshes and fibers were tested. The experimental results were discussed based on different theoretical approaches: analytical and Finite Element Method models. The main conclusions are: a the application of mortar overlays increases the wall strength, but not in a uniform manner; b the strengthening efficiency of wallettes loaded in axial compression is not proportional to the overlay mortar strength because it can be affected by the failure mechanisms of the wall; c steel mesh reinforced overlays in combination with high strength mortar show better efficiency, because the steel mesh mitigates the damage effects in the block wall and in the overlays themselves; d simplified theoretical methods of analysis as described in this paper can give satisfactory predictions of masonry wall behavior up to a certain level.

  12. Prediction of residual shear strength of corroded reinforced concrete beams

    Science.gov (United States)

    Imam, Ashhad; Azad, Abul Kalam

    2016-09-01

    With the aim of providing experimental data on the shear capacity and behavior of corroded reinforced concrete beams that may help in the development of strength prediction models, the test results of 13 corroded and four un-corroded beams are presented. Corrosion damage was induced by accelerated corrosion induction through impressed current. Test results show that loss of shear strength of beams is mostly attributable to two important damage factors namely, the reduction in stirrups area due to corrosion and the corrosion-induced cracking of concrete cover to stirrups. Based on the test data, a method is proposed to predict the residual shear strength of corroded reinforced concrete beams in which residual shear strength is calculated first by using corrosion-reduced steel area alone, and then it is reduced by a proposed reduction factor, which collectively represents all other applicable corrosion damage factors. The method seems to yield results that are in reasonable agreement with the available test data.

  13. 77 FR 70140 - Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, People's...

    Science.gov (United States)

    2012-11-23

    ...] Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, People's Republic of...'') initiated the second Sunset Reviews of the antidumping duty orders on steel concrete reinforcing bars from.... SUPPLEMENTARY INFORMATION: Background The antidumping duty orders on steel concrete reinforcing bars from...

  14. 77 FR 64127 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-10-18

    ... COMMISSION Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and... determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from Belarus... concrete reinforcing bar from Latvia and Moldova. The Commission found that the respondent interested party...

  15. 77 FR 18973 - Reinforced Concrete in Construction, and Preventing Backover Injuries and Fatalities

    Science.gov (United States)

    2012-03-29

    ... Reinforced Concrete in Construction, and Preventing Backover Injuries and Fatalities AGENCY: Occupational... aware of employee safety risks in two areas, reinforcing operations in concrete work (construction only... following methods (submissions relating to Reinforced Concrete in Construction to Docket No. OSHA-2010-0058...

  16. Influence of reinforcement mesh configuration for improvement of concrete durability

    Science.gov (United States)

    Pan, Chong-gen; Jin, Wei-liang; Mao, Jiang-hong; Zhang, Hua; Sun, Li-hao; Wei, Dong

    2017-08-01

    Steel bar in concrete structures under harsh environmental conditions, such as chlorine corrosion, seriously affects its service life. Bidirectional electromigration rehabilitation (BIEM) is a new method of repair technology for reinforced concrete structures in such chloride corrosion environments. By applying the BIEM, chloride ions can be removed from the concrete and the migrating corrosion inhibit can be moved to the steel surface. In conventional engineering, the concrete structure is often configured with a multi-layer steel mesh. However, the effect of the BIEM in such structures has not yet been investigated. In this paper, the relevant simulation test is carried out to study the migration law of chloride ions and the migrating corrosion inhibitor in a concrete specimen with complex steel mesh under different energizing modes. The results show that the efficiency of the BIEM increases 50% in both the monolayer steel mesh and the double-layer steel mesh. By using the single-sided BIEM, 87% of the chloride ions are removed from the steel surface. The different step modes can affect the chloride ion removal. The chloride ions within the range of the reinforcement protective cover are easier to be removed than those in the concrete between the two layers of steel mesh. However, the amount of migrating corrosion inhibitor is larger in the latter circumstances.

  17. Corrosion Effects on the Strength Properties of Steel Fibre Reinforced Concrete Containing Slag and Corrosion Inhibitor

    OpenAIRE

    Sivakumar Anandan; Sounthararajan Vallarasu Manoharan; Thirumurugan Sengottian

    2014-01-01

    Corrosion in steel can be detrimental in any steel rebar reinforced concrete as well as in the case of steel fibre reinforced concrete. The process of corrosion occurring in steel fibre incorporated concrete subjected to corrosive environment was systematically evaluated in this study. Concrete specimens were prepared with steel fibre inclusions at 1.5% Vf (volume fraction) of concrete and were added in slag based concrete (containing manufactured sand) and replaced with cement at 20%, 40%, ...

  18. Polarization Induced Deterioration of Reinforced Concrete with CFRP Anode

    Directory of Open Access Journals (Sweden)

    Ji-Hua Zhu

    2015-07-01

    Full Text Available This paper investigates the deterioration of reinforced concrete with carbon fiber reinforced polymer (CFRP anode after polarization. The steel in the concrete was first subjected to accelerated corrosion to various extents. Then, a polarization test was performed with the external attached CFRP as the anode and the steel reinforcement as the cathode. Carbon fiber reinforced mortar and conductive carbon paste as contact materials were used to adhere the CFRP anode to the concrete. Two current densities of 1244 and 2488 mA/m2, corresponding to the steel reinforcements were applied for 25 days. Electrochemical parameters were monitored during the test period. The deterioration mechanism that occurred at the CFRP/contact material interface was investigated by scanning electron microscopy (SEM and X-ray diffraction (XRD techniques. The increase of feeding voltage and the failure of bonding was observed during polarization process, which might have resulted from the deterioration of the interface between the contact material and CFRP. The formation and accumulation of NaCl crystals at the contact material/CFRP interface were inferred to be the main causes of the failure at the interface.

  19. Waste Plastic Fibre Reinforced Self Compacting Concrete

    Directory of Open Access Journals (Sweden)

    Mrs. Vijaya G.S Assistant Professor

    2016-05-01

    Full Text Available Self-compacting concrete is high performance concrete which is highly flowable, non-segregating, spread on its own weight and doesn‟t need any compaction. This paper deals with flow and strength characteristics such as compressive strength, split tensile strength, flexural strength and impact strength of Self-compacting concrete with various percentages of waste plastic fibres like 0%, 0.25%, 0.5%, 0.75%, 1.0%, 1.1%, 1.20%, 1.3% and 1.4% is added by weight of cement. The mix proportion for M40 grade of concrete was done by using Nan Su method (Cement: GGBS: Fine aggregate: Course aggregate 1: 0.705: 3.34: 2.62. Water powder (W/P ratio 0.36, cement content 280kg/m3 , GGBS 220 kg/m3 was calculated and maintained as constant throughout the experimental work for all eight mixes, only the superplastizers dosage was varied for different percentage of fibres. In this experimental investigation one control mix and eight (8 different mixes were considered. Totally 81 Cube, beam, Cylindrical specimens and square plates were casted, cured and tested as per IS specifications. For determining impact strength drop weight method was used. The results obtained indicate that fresh (workability characteristics satisfy the lower and upper limit as suggested by EFNARC. The tests on hardened properties indicate that the compressive strength, split tensile strength, flexural strength was improved proportionally with the addition of waste plastic fibers upto 1.0% by weight of cement and then decreases. The impact strength improved proportionally with addition of fibres upto 1.2% by weight of cement and then decreases.

  20. Chloride Ion Critical Content in Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Chloride ion critical content was studied under soaking and cycle of dry and wet conditions,with three electrochemical nondestructive measuring techniques, i e, half-cell potential, A C impedance, and time potential. The experimental results show that chloride ion critical content is primarily determined by the water cement ratio, while for the same concrete mixture the chloride ion critical content in soaking conditions is larger than that in a cycle of dry and wet conditions.

  1. Proposal of a new indicator to define ductility applied to corroded steel reinforcement on concrete structures

    OpenAIRE

    Cobo Escamilla, Alfonso; Moreno Fernandez, Maria Esther; Fernández Cánovas, Manuel

    2010-01-01

    The carbonation of concrete or the chlorides ingress in such quantity to reach the level of bars is triggers of reinforcement corrosion. One of the most significant effects of reinforcing steel corrosion on reinforced concrete structures is the decline in the ductility-related properties of the steel. Reinforcement ductility has a decisive effect on the overall ductility of reinforced concrete structures. Different Codes classify the type of steel depending on their ductility defined by...

  2. A Study on Steel Fiber Reinforced Normal Compacting Concrete

    Directory of Open Access Journals (Sweden)

    Dr. B. Krishna Rao,

    2016-08-01

    Full Text Available Plain concrete which is strong in compressive strength possesses a very low tensile strength, limited ductility and little resistance to cracking. Internal micro cracks are inherently present in the concrete due to drying, shrinkage and poor tensile strength, eventually leading to brittle fracture of concrete. Hence fibres are added to concrete to overcome these disadvantages. Fibre Reinforced Concrete (FRC is a concrete composite of cement, fine and coarse aggregate and fibres with different proportions. In plain concrete, micro cracks develop even before loading, particularly due to drying, shrinkage or other causes of volume change. The width of these initial cracks seldom exceeds few microns. When loaded the micro cracks propagate and open up, due to the effect of stress concentration additional cracks form in place of minor defects. Fibres enable concrete to progress from plastic state to hardened state without weakness. This is achieved by the reduction of micro crack formation, reduced segregation and decreasing the scope of capillary formation, thus reducing permeability. Generally, fibres are chosen depending upon the aspect ratio. Out of all types of fibres, steel fibres are mostly used because steel has high modulus of elasticity, high elongation, high tensile strength and the bond between steel and the fibre is enormous. The present experimental investigation was carried out to evaluate the influence of steel fibres on physical and mechanical properties of concrete, containing cold drawn carbon steel fibres of hooked end type having aspect ratio of 50 with diameter 0.6mm and length 30mm with varying percentages of 0.5%, 1%, 1.5% and 2.0% volume fraction is added to the concrete. Concrete is evaluated for compressive, split tensile and flexural strength at 7, 28 and 90 days, with the addition of 1.5% fibres, test results show the maximum compressive, split tensile and flexural strength, it becomes the optimum value. Split tensile and

  3. Experimental Investigation of the Capacity of Steel Fibers to Ensure the Structural Integrity of Reinforced Concrete Specimens Coated with CFRP Sheets

    Science.gov (United States)

    Gribniak, V.; Arnautov, A. K.; Norkus, A.; Tamulenas, V.; Gudonis, E.; Sokolov, A.

    2016-07-01

    The capacity of steel fibers to ensure the structural integrity of reinforced concrete specimens coated with CFRP sheets was investigated. Test data for four ties and eight beams reinforced with steel or glass-FRP bars are presented. Experiments showed that the fibers significantly increased the cracking resistance and altered the failure character from the splitting of concrete to the debonding of the external sheets, which noticeably increased the load-carrying capacity of the strengthened specimens.

  4. Modeling the Time-to Corrosion Cracking of the Cover Concrete in Chloride Contaminated Reinforced Concrete Structures

    OpenAIRE

    Liu, Youping

    1996-01-01

    Significant factors on steel corrosion in chloride contaminated reinforced concrete and time-to-corrosion cracking were investigated in this study. Sixty specimens were designed with seven admixed chloride contents, three concrete cover depths, two reinforcing steel bar diameters, two exposure conditions, and a typical concrete with water to cement ratio of 0.45. Corrosion current density (corrosion rate), corrosion potential, ohmic resistance of concrete and temperature were measured monthly...

  5. Effect Of Age And Concrete Cover Thickness On Steel Reinforcement Corrosion At Splash Zone In Reinforced Concrete Hydraulic Structures

    Directory of Open Access Journals (Sweden)

    Nada M. Al- Galawi

    2015-08-01

    Full Text Available Corrosion of reinforcing steel bars in reinforced concrete is considered as one of the biggest problems that face countries overlooking to the Arabian Gulf including Iraq. The research aims to study the effect of the corrosion of steel bars in concrete structures that are exposed to wetting and drying via waves. Reinforced concrete samples were exposed to marine simulated environment for 90 days using prepared system for this purpose. At the end of exposure period polarization test was implemented to measure the actual corrosion rate in each sample. After that the corrosion process was accelerated using impressed current technique by applying a constant electric current DC to the reinforcing bars. Depending on the corrosion current in natural conditions which was measured in polarization test periods of exposing samples to accelerated corrosion current so as to maintain virtual exposure ages of 5 and 25 years of exposure to natural corrosion were calculated. The results showed a remarkable increase in the corrosion current of steel bars in samples that had lower concrete cover thickness. The increase in the cover thickness from 20mm to 40 and 65 mm had a significant effect on reducing the corrosion current at the age of 90 days to about 70 of its original value in both cases. At the virtual exposure age of 5 years the reduction percentage in the corrosion current resulted from increasing cover thickness from 20mm to 40 and 65 mm were 43 and 79 respectively.

  6. Bamboo Reinforced Concrete Truss Bridge for Rural Infrastructure

    Directory of Open Access Journals (Sweden)

    D. Nuralinah

    2014-04-01

    Full Text Available Bamboo is one of a potential renewable construction material in the village. Bamboo is known to have a high mechanical strength in direction of the fibers. The weakness of bamboo in lateral direction of the fiber could be solved by constructing a composite structure with the concrete. The appropriate construction with hold the loads in axial direction is a truss structure. In a bamboo concrete truss structure, the bars are composed from the concrete column with a bamboo reinforcement. The research studies about the performance of the bridge and the effect of loading position on the strain and deformation of bamboo reinforced concrete truss bridge. The bridge whose span and width are respectively 1.5 m and 1.2 m was prepared. Load applied to the truss bridge conducted by using vehicle load changes with position. Mounting the strains gauge in bamboo reinforcement of primary truss is to observe the strain. The LVDT is used to observe the deflection of the truss bridge. The results show that the loading position influences the strain and deformation as well as a theoretical view.

  7. Influence of transverse reinforcement on perforation resistance of reinforced concrete slabs under hard missile impact

    Energy Technology Data Exchange (ETDEWEB)

    Orbovic, Nebojsa, E-mail: nebojsa.orbovic@cnsc-ccsn.gc.ca; Sagals, Genadijs; Blahoianu, Andrei

    2015-12-15

    This paper describes the work conducted by the Canadian Nuclear Safety Commission (CNSC) related to the influence of transverse reinforcement on perforation capacity of reinforced concrete (RC) slabs under “hard” missile impact (impact with negligible missile deformations). The paper presents the results of three tests on reinforced concrete slabs conducted at VTT Technical Research Centre (Finland), along with the numerical simulations as well as a discussion of the current code provisions related to impactive loading. Transverse reinforcement is widely used for improving the shear and punching strength of concrete structures. However, the effect of this reinforcement on the perforation resistance under localized missile impact is still unclear. The goal of this paper is to fill the gap in the current literature related to this topic. Based on similar tests designed by the authors with missile velocity below perforation velocity, it was expected that transverse reinforcement would improve the perforation resistance. Three slabs were tested under almost identical conditions with the only difference being the transverse reinforcement. One slab was designed without transverse reinforcement, the second one with the transverse reinforcement in form of conventional stirrups with hooks and the third one with the transverse reinforcement in form of T-headed bars. Although the transverse reinforcement reduced the overall damage of the slabs (the rear face scabbing), the conclusion from the tests is that the transverse reinforcement does not have important influence on perforation capacity of concrete slabs under rigid missile impact. The slab with T-headed bars presented a slight improvement compared to the baseline specimen without transverse reinforcement. The slab with conventional stirrups presented slightly lower perforation capacity (higher residual missile velocity) than the slab without transverse reinforcement. In conclusion, the performed tests show slightly

  8. Study of Bond Characteristics of Reinforced Waste Glass Aggregate Concrete

    Science.gov (United States)

    Rajagopalan, P.; Balaji, V.; Unnikrishnan, N.; Jainul Haq, T.; Bhuvaneshwari, P.

    2017-07-01

    The conformity of properties of waste glass aggregate with conventional aggregate was found out. Nine cubes (150mm x 150mm x 150mm) were cast out of which three were used for control concrete, three were fully replaced with waste glass as coarse aggregate, three were partially replaced(50%) with waste glass as fine aggregate. Six cylinders (150mm x 300mm) were cast out of which two for control concrete, two cylinders with coarse aggregate fully replaced with waste glass aggregate(WGA) and remaining two cylinders with partially replaced (50%) fine aggregate with waste glass aggregate. Cured specimens were subjected to compression and split-tensile test to ascertain the characteristic compressive strength and split tensile strength. Since the surface of the coarse aggregate plays a significant role in bonding of the rebar in reinforced concrete, pull-out test on both control and Waste Glass Aggregate (WGA) cube specimens (150mm x 150mm with 20mm diameter steel rods) were conducted. Scanning Electron Microscopy (SEM) analysis has been done for better understanding of bonding properties in waste glass fine aggregate(WGFA) and waste glass coarse aggregate(WGCA) concrete. Comparison of the results with that of control specimens showed that waste glass could be effectively used as aggregates in reinforced concrete construction.

  9. Nonlinear Finite Element Analysis of Reinforced Concrete Shells

    Directory of Open Access Journals (Sweden)

    Mustafa K. Ahmed

    2013-05-01

    Full Text Available This investigation is to develop a numerical model suitable for nonlinear analysis of reinforced concrete shells. A nine-node Lagrangian element Figure (1 with enhanced shear interpolation will be used in this study. Table (1 describes shape functions and their derivatives of this element.An assumed transverse shear strain is used in the formulation of this element to overcome shear locking. Degenerated quadratic thick plate elements employing a layered discrelization through the thickness will be adopted. Different numbers of layers for different thickness can be used per element. A number of layers between (6 and 10 have proved to be appropriate to represent the nonlinear material behavior in structures. In this research 8 layers will be adequate. Material nonlinearities due to cracking of concrete, plastic flow or crushing of concrete in compression and yield condition of reinforcing steel are considered. The maximum tensile strength is used as a criterion for crack initiation. Attention is given to the tension stiffening phenomenon and the degrading effect of cracking on the compressive and shear strength of concrete. Perfect bond between concrete and steel is assumed. Attention is given also to geometric nonlinearities. An example have been chosen in order to demonstrate the suitability of the models by comparing the predicted behaviour with the experimental results for shell exhibiting various modes of failure.

  10. Mechanical Properties of Fiber Reinforced Lightweight Concrete Containing Surfactant

    Directory of Open Access Journals (Sweden)

    Yoo-Jae Kim

    2010-01-01

    Full Text Available Fiber reinforced aerated lightweight concrete (FALC was developed to reduce concrete's density and to improve its fire resistance, thermal conductivity, and energy absorption. Compression tests were performed to determine basic properties of FALC. The primary independent variables were the types and volume fraction of fibers, and the amount of air in the concrete. Polypropylene and carbon fibers were investigated at 0, 1, 2, 3, and 4% volume ratios. The lightweight aggregate used was made of expanded clay. A self-compaction agent was used to reduce the water-cement ratio and keep good workability. A surfactant was also added to introduce air into the concrete. This study provides basic information regarding the mechanical properties of FALC and compares FALC with fiber reinforced lightweight concrete. The properties investigated include the unit weight, uniaxial compressive strength, modulus of elasticity, and toughness index. Based on the properties, a stress-strain prediction model was proposed. It was demonstrated that the proposed model accurately predicts the stress-strain behavior of FALC.

  11. EMBEDDED CAPACITOR SENSOR FOR MONITORING CORROSION OF REINFORCEMENT IN CONCRETE

    Directory of Open Access Journals (Sweden)

    SITI FATIMAH ABDUL RAHMAN

    2012-04-01

    Full Text Available Corrosion of reinforcement can affect durability and integrity of reinforced concrete structures. Repair cost for a badly corroded structure can be very costly and time consuming. In this paper, several capacitor sensors were developed to monitor corrosion potential of reinforcement in concrete. The impedance capacitive of sensors was tested in various acid and alkali solutions using Agilent 4284A Precision LCR meter. The other sensors were tied to reinforcements and embedded in concrete specimen contaminated with 5% chloride to measure corrosion potential. The specimens were exposed to the corrosion chamber and indoor environments. From the research, it was found that the sensor can measure the impedance capacitive at different frequencies in the aggressive solutions. Besides, it was observed that the patterns of corrosion potential shown by the embedded sensors were similar to the SRI sensor. The output values from embedded sensor are in a range of recommendation by the ASTM-C876. Eventually, the bars were found corroded from the broken specimens that confirmed the detection of corrosion activities as recorded by the sensors.

  12. Self-monitoring fiber reinforced polymer strengthening system for civil engineering infrastructures

    Science.gov (United States)

    Jiang, Guoliang; Dawood, Mina; Peters, Kara; Rizkalla, Sami

    2008-03-01

    Fiber reinforced polymer (FRP) materials are currently used for strengthening civil engineering infrastructures. The strengthening system is dependant on the bond characteristics of the FRP to the external surface of the structure to be effective in resisting the applied loads. This paper presents an innovative self-monitoring FRP strengthening system. The system consists of two components which can be embedded in FRP materials to monitor the global and local behavior of the strengthened structure respectively. The first component of the system is designed to evaluate the applied load acting on a structure based on elongation of the FRP layer along the entire span of the structure. Success of the global system has been demonstrated using a full-scale prestressed concrete bridge girder which was loaded up to failure. The test results indicate that this type of sensor can be used to accurately determine the load prior to failure within 15 percent of the measured value. The second sensor component consists of fiber Bragg grating sensors. The sensors were used to monitor the behavior of steel double-lap shear splices tested under tensile loading up to failure. The measurements were used to identify abnormal structural behavior such as epoxy cracking and FRP debonding. Test results were also compared to numerical values obtained from a three dimensional shear-lag model which was developed to predict the sensor response.

  13. Review of Carbon Fiber Reinforced Polymer Reinforced Material in Concrete Structure

    Directory of Open Access Journals (Sweden)

    Ayuddin Ayuddin

    2016-05-01

    Full Text Available Carbon Fiber Reinforced Polymer (FRP is a material that is lightweight, strong, anti-magnetic and corrosion resistant. This material can be used as an option to replace the steel material in concrete construction or as material to improve the strength of existing construction. CFRP is quite easy to be attached to the concrete structure and proved economically used as a material for repairing damaged structures and increase the resilience of structural beams, columns, bridges and other parts of the structure against earthquakes. CFRP materials can be shaped sheet to be attached to the concrete surface. Another reason is due to the use of CFRP has a higher ultimate strength and lower weight compared to steel reinforcement so that the handling is significantly easier. Through this paper suggests that CFRP materials can be applied to concrete structures, especially on concrete columns. Through the results of experiments conducted proved that the concrete columns externally wrapped with CFRP materials can increase the strength. This treatment is obtained after testing experiments on 130 mm diameter column with a height of 700 mm with concentric loading method to collapse. The experimental results indicate that a column is wrapped externally with CFRP materials can achieve a load capacity of 250 kN compared to the concrete columns externally without CFRP material which only reached 150 kN. If the column is given internally reinforcing steel and given externally CFRP materials can reach 270 kN. It shows that CFRP materials can be used for concrete structures can even replace reinforcing steel that has been widely used in building construction in Indonesia.

  14. The Effect of Externally Retrofitted Carbon Fiber Reinforced Polymer Composites on the Ductility of Reinforced Concrete Beams

    Science.gov (United States)

    2007-11-02

    Reinforcement Ratios 84 8-5 Ductility Indices 86 5 LIST OF FIGURES FIGURE PAGE 2-1 Failure Modes of Concrete Beams 17 2-2 Composite Jacket Installation...20 2-3 Composite Jacket Application 20 2-4 Four Point Bending Configuration 21 3-1 Stress-Strain Relationship for Concrete 27 3-2 Standard Rebar 28 3...researchers around the world, such as reinforcing and prestressing concrete structures, seismic retrofitting of concrete and unreinforced masonry

  15. Effect of Reinforcement on Early-Age Concrete Temperature Stress: Preliminary Experimental Investigation and Analytical Simulation

    Directory of Open Access Journals (Sweden)

    Jianda Xin

    2015-01-01

    Full Text Available For concrete under short-term loading, effect of reinforcement on concrete crack resistance capability is usually negligible; however, recent research results show that extension of this viewpoint to concrete under long-term loading (temperature variation may be unsuitable. In order to investigate this phenomenon, this paper presents the experimental and analytical results of early-age reinforced concrete temperature stress development under uniaxial restraint. The experiments were carried out on a temperature stress testing machine (TSTM. Experimental results show that the coupling of reinforcement and concrete creep behavior influenced the concrete temperature stress development, and nearly 16% of concrete stress was reduced in the current research. Moreover, the cracking time of reinforced concrete was also delayed. Finally, based on the principle of superposition, analytical simulations of effect of reinforcement on concrete temperature stress have been performed.

  16. Critical chloride content for reinforced concrete and its relationship to concrete resistivity

    NARCIS (Netherlands)

    Polder, R.B.

    2009-01-01

    The critical chloride content for initiation of reinforcement corrosion is an essential element in service life design and modelling of concrete structures.The critical content is laden with questions regarding its definition, experimental assessment and practical aspects. It should be addressed by

  17. Up-to-date technologies of producing reinforced concrete constructions in transport industry

    Directory of Open Access Journals (Sweden)

    Ю. А. Клімов

    2000-09-01

    Full Text Available Presented is the analysis of the works at XIII Congress of International Federeation of pre­reinforced concrete construction (FIP. Scientific researches and technical solutions of reinforced concrete constructions realized in the developed countries have determined the main trends in perfection of concrete constructions in the next century (perfection of data on quality of constructive solutions of reinforcement with on-metallic fibrous materials, energy saving technologies of concrete production, development and investigation of perspective technical solutions

  18. An extended finite element model for modelling localised fracture of reinforced concrete beams in fire

    OpenAIRE

    Liao, F; Huang, Z.

    2015-01-01

    Open Access funded by Engineering and Physical Sciences Research Council under a Creative Commons license. A robust finite element procedure for modelling the localised fracture of reinforced concrete beams at elevated temperatures is developed. In this model a reinforced concrete beam is represented as an assembly of 4-node quadrilateral plain concrete, 3-node main reinforcing steel bar, and 2-node bond-link elements. The concrete element is subdivided into layers for considering the temp...

  19. Advance study of fiber-reinforced self-compacting concrete

    Energy Technology Data Exchange (ETDEWEB)

    Mironova, M., E-mail: mirona@imbm.bas.bg; Ivanova, M., E-mail: magdalena.ivanova@imbm.bas.bg; Naidenov, V., E-mail: valna53@mail.bg [Institute of Mechanics, Bulgarian Academy of Sciences, Acad. G. Bonchev str., bl. 4, Sofia 1113 (Bulgaria); Georgiev, I., E-mail: ivan.georgiev@parallel.bas.bg [Institute of Information and Communication Technologies & Institute of Mathematics and Informatics, Bulgarian Academy of Sciences, Acad. G. Bonchev str., Sofia 1113 (Bulgaria); Stary, J., E-mail: stary@ugn.cas.cz [Institute of Geonics Czech Academy of Sciences, Studentska str., Ostrava 1768 (Czech Republic)

    2015-10-28

    Incorporation in concrete composition of steel macro- and micro – fiber reinforcement with structural function increases the degree of ductility of typically brittle cement-containing composites, which in some cases can replace completely or partially conventional steel reinforcement in the form of rods and meshes. Thus, that can reduce manufacturing, detailing and placement of conventional reinforcement, which enhances productivity and economic efficiency of the building process. In this paper, six fiber-reinforced with different amounts of steel fiber cement-containing self-compacting compositions are investigated. The results of some of their main strength-deformation characteristics are presented. Advance approach for the study of structural and material properties of these type composites is proposed by using the methods of industrial computed tomography. The obtained original tomography results about the microstructure and characteristics of individual structural components make it possible to analyze the effective macro-characteristics of the studied composites. The resulting analytical data are relevant for the purposes of multi-dimensional modeling of these systems. Multifactor structure-mechanical analysis of the obtained with different methods original scientific results is proposed. It is presented a conclusion of the capabilities and effectiveness of complex analysis in the studies to characterize the properties of self-compacting fiber-reinforced concrete.

  20. Advance study of fiber-reinforced self-compacting concrete

    Science.gov (United States)

    Mironova, M.; Ivanova, M.; Naidenov, V.; Georgiev, I.; Stary, J.

    2015-10-01

    Incorporation in concrete composition of steel macro- and micro - fiber reinforcement with structural function increases the degree of ductility of typically brittle cement-containing composites, which in some cases can replace completely or partially conventional steel reinforcement in the form of rods and meshes. Thus, that can reduce manufacturing, detailing and placement of conventional reinforcement, which enhances productivity and economic efficiency of the building process. In this paper, six fiber-reinforced with different amounts of steel fiber cement-containing self-compacting compositions are investigated. The results of some of their main strength-deformation characteristics are presented. Advance approach for the study of structural and material properties of these type composites is proposed by using the methods of industrial computed tomography. The obtained original tomography results about the microstructure and characteristics of individual structural components make it possible to analyze the effective macro-characteristics of the studied composites. The resulting analytical data are relevant for the purposes of multi-dimensional modeling of these systems. Multifactor structure-mechanical analysis of the obtained with different methods original scientific results is proposed. It is presented a conclusion of the capabilities and effectiveness of complex analysis in the studies to characterize the properties of self-compacting fiber-reinforced concrete.

  1. Effects of Reinforcement Configuration on Reserve Capacity of Concrete Slabs

    Science.gov (United States)

    1985-08-01

    Reinforced concreted Tensile membrane,, Buried shelters/ Shelters/ ..i, Civil defense, Slab capacity, 120. A34TlRACT rCcnhma in~ r aidit noe..era aad...CHAPTER 1 I XTPODLCT, CI At the- iiti it io., of this Study civil d~efense plwlgcalled for the .;evacuation of nonessenrt*I51 pezrsonnel to safe (lower...lqbal and Derecho (Reference 10). The reinforcement ratio, p , was 0.0062 in "Christianscn’s te,;tts and varied from 0.0023 to 0.0093 in Roberts’ tests

  2. 砌体结构外套预制钢筋混凝土墙板加固及隔震加层振动台试验研究%Shaking table test of masonry structures strengthened with external prefabricated reinforced concrete wall and with added story isolation

    Institute of Scientific and Technical Information of China (English)

    王曙光; 苗启松; 刘金龙; 刘伟庆; 杜东升

    2012-01-01

    为研究砌体结构外套预制钢筋混凝土墙板加固技术的加固效果,并探讨在其顶部隔震加层的可行性,进行了3个相似比为1/4模型的振动台对比试验,模型分别是加固砌体结构模型、加固后加层非隔震结构模型和加固后加层隔震结构模型。试验测试了模型结构的动力特性及其在不同地震作用下的动力响应,为了分析结构震损后的动力响应,在试验模型经历罕遇地震作用下的损伤后又继续进行不同水准地震输入试验。试验结果表明:加层非隔震结构的上部钢框架鞭稍效应非常明显;加层隔震结构有效延长了结构自振周期,增大了结构阻尼比。加层隔震结构既有效降低了下部砌体结构的地震响应又降低了上部钢框架的地震响应,其加固效果和抗震性能优越。同时,震损后加层隔震结构的隔震效果明显降低,下部砌体的加速度反应可能大于加固结构和加层非隔震结构,建议在设计时充分考虑这种不利影响。%In order to research the reinforcement effects on masonry structure strengthened with external prefabricated reinforced concrete wall and investigate the possibility of added story isolation on the top of reinforced masonry structure, the shaking table tests of three 1/4. scaled models were conducted. These three models were reinforced masonry structure model, reinforced masonry structure with added story model and reinforced masonry structure with added story isolation model. The dynamic characteristics and seismic response of models were evaluated under different levels of earthquakes. And then, the models subjected to rare seismic cases were tested again to analyze the dynamic responses of damaged structures. The results indicate that added story isolation structure can prolong the structural vibration periods efficiently and increase the damping ratio. Whiplash effect of superstructure of added story non- isolation structure is very

  3. 复材加固受损混凝土梁的干湿循环耐久性能研究∗%STUDY OF DURABILITY OF DAMAGED REINFORCED CONCRETE BEAMS STRENGTHENED WITH COMPOSITE MATERIALS SUBJECTED TO WET-DRY CYCLES

    Institute of Scientific and Technical Information of China (English)

    谢燕; 邓军; 王琪琛

    2016-01-01

    纤维复材的加固技术正越来越多地被用来修复受损钢筋混凝土( RC)桥梁。而在南方湿热环境下,胶黏剂的性能退化及氯离子对RC梁的侵蚀作用,将对被修复桥梁的耐久性产生不利影响。为此对干湿循环下碳纤维布加固受损RC梁的抗弯承载力及氯离子的扩散情况进行研究。干湿循环加速老化试验包括3个月和6个月两种工况,一次干湿循环为24 h,包括湿环境(3�5%盐水浸泡)10 h和干环境(40℃热风)14 h。试验结果表明:干湿循环略为减小了加固梁的刚度,导致了混凝土与碳纤维布黏结界面的退化;干湿循环前3个月,加固梁的承载能力有明显降低,而后逐步稳定;受损RC梁裂缝附近的氯离子含量远高于其他部分;碳纤维布加固减缓了氯离子由梁底对RC梁的侵蚀,对带裂缝工作的受损梁有较好的保护作用。%Fiber reinforced polymer materials are increasingly being used to repair the damaged reinforced concrete ( RC) bridges. The degradation of adhesive bonding in a wet⁃dry environment, however, may have an adverse effect on the long term durability of the repaired bridges. This paper presented an experimental study on the flexural capacity and diffusion of chlorions of damaged RC T⁃beams strengthened with carbon fiber sheets subjected to the wet⁃dry cycles. The specimens subjected to wet⁃dry environment were exposed to a period of 3 months or 6 months. A wet⁃dry cycle was 24 h including a wet cycle ( salt water) of 10 h and a dry cycle ( hot air at 40 ℃) of 14 h. The experimental results showed that a slight reduction in stiffness was observed for the strengthened beams due to wet⁃dry exposure. The wet⁃dry cycles induced degradation to bond at the concrete carbon fiber sheets interface. Only in the first 3 months, however, the wet⁃dry environmental exposure could obviously reduce the strength of the retrofitted beams. The content

  4. Fatigue Strain and Damage Analysis of Concrete in Reinforced Concrete Beams under Constant Amplitude Fatigue Loading

    Directory of Open Access Journals (Sweden)

    Fangping Liu

    2016-01-01

    Full Text Available Concrete fatigue strain evolution plays a very important role in the evaluation of the material properties of concrete. To study fatigue strain and fatigue damage of concrete in reinforced concrete beams under constant amplitude bending fatigue loading, constant amplitude bending fatigue experiments with reinforced concrete beams with rectangular sections were first carried out in the laboratory. Then, by analyzing the shortcomings and limitations of existing fatigue strain evolution equations, the level-S nonlinear evolution model of fatigue strain was constructed, and the physical meaning of the parameters was discussed. Finally, the evolution of fatigue strain and fatigue damage of concrete in the compression zone of the experimental beam was analyzed based on the level-S nonlinear evolution model. The results show that, initially, fatigue strain grows rapidly. In the middle stages, fatigue strain is nearly a linear change. Because the experimental data for the third stage are relatively scarce, the evolution of the strain therefore degenerated into two phases. The model has strong adaptability and high accuracy and can reflect the evolution of fatigue strain. The fatigue damage evolution expression based on fatigue strain shows that fatigue strain and fatigue damage have similar variations, and, with the same load cycles, the greater the load level, the larger the damage, in line with the general rules of damage.

  5. Producing Durable Continuously Reinforced Concrete Pavement using Glass-ceramic Coated Reinforcing Steel

    Science.gov (United States)

    2010-02-01

    Portland cement is manufactured by firing the clinker at 1400 C Enamel application produces no changes BUILDING STRONG® Treatment Average Peak...ceramic Coated Reinforcing Steel 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER... transition zone at the surface of the reinforcement steel is often the most permeable part of the concrete BUILDING STRONG® Schematic of Ceramic

  6. Optimal Material Layout - Applied on Reinforced Concrete Slabs

    DEFF Research Database (Denmark)

    Dollerup, Niels; Jepsen, Michael S.; Damkilde, Lars

    2015-01-01

    to determine the optimal material layout of a slab in the ultimate load state, based on simple inputs such as outer geometry, boundary conditions, multiple load cases and design domains. The material layout of the optimal design can either be fully orthotropic or isotropic, or a combination with a predefined......This paper introduces a general, finite-element-based optimisation tool for improving the material layout of concrete structures. The application presented is general and exemplified by material optimisation of reinforced concrete slabs. By utilising the optimisation tool, it is possible...... coupling between design domains and reinforcement directions. The implementation is a lower bound formulation, resulting in a convex optimisation problem that consists of a number of linear constraints from the equilibrium equations and a number of convex non-linear constraints from the yield criteria...

  7. Steel fiber reinforced concrete behavior, modelling and design

    CERN Document Server

    Singh, Harvinder

    2017-01-01

    This book discusses design aspects of steel fiber-reinforced concrete (SFRC) members, including the behavior of the SFRC and its modeling. It also examines the effect of various parameters governing the response of SFRC members in detail. Unlike other publications available in the form of guidelines, which mainly describe design methods based on experimental results, it describes the basic concepts and principles of designing structural members using SFRC as a structural material, predominantly subjected to flexure and shear. Although applications to special structures, such as bridges, retaining walls, tanks and silos are not specifically covered, the fundamental design concepts remain the same and can easily be extended to these elements. It introduces the principles and related theories for predicting the role of steel fibers in reinforcing concrete members concisely and logically, and presents various material models to predict the response of SFRC members in detail. These are then gradually extended to d...

  8. Mixed Consolidation Solution for a Reinforced Concrete Structure

    Science.gov (United States)

    Lute, M.

    2016-06-01

    During the last years, reinforced concrete structures become subject for rehabilitation due to two factors: their long life span and large change in norms that leaded to a large increase of seismic loads in Eastern Europe. These lead to a necessity for rehabilitation of existing building stock in order to use them during their entire life span at the maximum potential. The present paper proposes a solution for rehabilitation for three reinforced concrete building of a hospital, that consumed a half of their life span and do not correspond anymore to present norms. The chosen solution is a combination between CFRP rehabilitation and increase of structural elements cross section in order to achieve the stiffness balance in the structure nodes that is required by present norms. As a further matter, correction in stiffness of local elements diminished the lateral drifts of the structure and improved the global seismic response of the building.

  9. Quantitative approach for damage detection of reinforced concrete frames

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The objective of this paper is to provide an analytical basis for the quantitative evaluation of damage to a reinforced concrete structure based on the vibration data obtained by using the damage detection technique. A partial reinforced concrete system of a weak beam/strong column moment frame is chosen as an example. A pushover analysis is carried out in order to numerically examine both the story shear-relative displacement characteristics and the associated damage level. In the analysis, a two dimensional nonlinear finite element analysis is employed considering several constitutive models. As a result, the degradation of the stiffness at the damaged story is characterized in association with the story relative displacement. It is also pointed out that the rotation angle of the column-base is highly correlated with the story relative displacement. Based on the analytical findings, quantitative approaches for a structural health monitoring system are suggested considering both the current sensor technologies and those available in the future.

  10. Punching strength of reinforced concrete flat slabs without shear reinforcement

    Directory of Open Access Journals (Sweden)

    P. V. P. Sacramento

    Full Text Available Punching strength is a critical point in the design of flat slabs and due to the lack of a theoretical method capable of explaining this phenomenon, empirical formulations presented by codes of practice are still the most used method to check the bearing capacity of slab-column connections. This paper discusses relevant aspects of the development of flat slabs, the factors that influence the punching resistance of slabs without shear reinforcement and makes comparisons between the experimental results organized in a database with 74 slabs carefully selected with theoretical results using the recommendations of ACI 318, EUROCODE 2 and NBR 6118 and also through the Critical Shear Crack Theory, presented by Muttoni (2008 and incorporated the new fib Model Code (2010.

  11. Study of the stress-strain state of compressed concrete elements with composite reinforcement

    Directory of Open Access Journals (Sweden)

    Bondarenko Yurii

    2017-01-01

    Full Text Available The efficiency analysis of the application of glass composite reinforcement in compressed concrete elements as a load-carrying component has been performed. The results of experimental studies of the deformation-strength characteristics of this reinforcement on compression and compressed concrete cylinders reinforced by this reinforcement are presented. The results of tests and mechanisms of sample destruction have been analyzed. The numerical analysis of the stress-strain state has been performed for axial compression of concrete elements with glasscomposite reinforcement. The influence of the reinforcement percentage on the stressed state of a concrete compressed element with the noted reinforcement is estimated. On the basis of the obtained results, it is established that the glass-composite reinforcement has positive effect on the strength of the compressed concrete elements. That is, when calculating the load-bearing capacity of such structures, the function of composite reinforcement on compression should not be neglected.

  12. Collapse mechanisms and strength prediction of reinforced concrete pile caps

    DEFF Research Database (Denmark)

    Jensen, Uffe G.; Hoang, Linh Cao

    2012-01-01

    This paper describes an upper bound plasticity approach for strength prediction of reinforced concrete pile caps. A number of collapse mechanisms are identified and analysed. The procedure leads to an estimate of the load-carrying capacity and an identification of the critical collapse mechanism....... It is argued that the upper bound approach may be a useful complement to the widely used lower bound strut-and-tie method. Especially when dealing with strength assessment of existing structures....

  13. Fatigue testing of reinforced-concrete steel bars

    Science.gov (United States)

    Maropoulos, S.; Fasnakis, D.; Voulgaraki, Ch; Papanikolaou, S.; Maropoulos, A.; Antonatos, A.

    2016-11-01

    A number of low-cycle fatigue tests were conducted on reinforced-concrete steel bars of various diameters to study their behaviour under axial loading according to EN 10080 and EN 1421-3. Scanning electron microscopy was used to study the specimen fracture surfaces. The problems faced during testing are presented and a specimen preparation method is described that will aid researchers on fatigue testing to obtain accurate test results and save on material and time.

  14. Cost analysis of reinforced concrete slabs and columns

    OpenAIRE

    Spuś, Piotr

    2013-01-01

    The construction industry is increasingly looking for solutions that are both simple and effective and that provide cost savings, speed and flexibility of execution. Two-way slabs are a form of construction unique to reinforced concrete comparing with the other major structural materials. It is an efficient, economical, and widely used structural system. The present dissertation aims to analyze and compare costs between four types of slabs: waffle slab with recuperate molds, flat slabs wit...

  15. Thermal analysis of reinforced concrete beams and frames

    Directory of Open Access Journals (Sweden)

    Essam H. El-Tayeb

    2017-04-01

    The obtained results of the studied cases reveal that material modeling of reinforced concrete beams and frames plays a major role in how these structures react to temperature variation. Cracking contributes to the release of significant portion of temperature restrain and in some cases this restrain is almost eliminated. The response of beams and frames deviates significantly based on the temperature gradient, linear or nonlinear; hence, the nonlinear temperature gradient which is the realistic profile is important to implement in the analysis.

  16. Assessment of Commercial Corrosion Inhibiting Admixtures for Reinforced Concrete

    OpenAIRE

    Brown, Michael Carey

    1999-01-01

    Corrosion of reinforcing steel in concrete exposed to chloride-laden environments is a well-known and documented phenomenon. The need for cost effective systems for protection against corrosion has become increasingly clear since the first observations of severe corrosion damage to interstate bridges in the 1960's. As one potential solution to the mounting problem of corrosion deterioration of structures, corrosion-inhibiting admixtures have been researched and introduced into service. ...

  17. Interfacial chemistry of zinc anodes for reinforced concrete structures

    Energy Technology Data Exchange (ETDEWEB)

    Covino, B.S. Jr.; Bullard, S.J.; Cramer, S.D.; Holcomb, G.R. [Dept. of Energy, Albany, OR (United States). Albany Research Center; McGill, G.E.; Cryer, C.B. [Oregon Dept. of Transportation, Salem, OR (United States); Stoneman, A. [International Lead Zinc Research Organization, Research Triangle Park, NC (United States); Carter, R.R. [California Dept. of Transportation, Sacramento, CA (United States)

    1997-12-01

    Thermally-sprayed zinc anodes are used in both galvanic and impressed current cathodic protection systems for reinforced concrete structures. The Albany Research Center, in collaboration with the Oregon Department of Transportation, has been studying the effect of electrochemical aging on the bond strength of zinc anodes for bridge cathodic protection systems. Changes in anode bond strength and other anode properties can be explained by the chemistry of the zinc-concrete interface. The chemistry of the zinc-concrete interface in laboratory electrochemical aging studies is compared with that of several bridges with thermal-sprayed zinc anodes and which have been in service for 5 to 10 years using both galvanic and impressed current cathodic protection systems. The bridges are the Cape Creek Bridge on the Oregon coast and the East Camino Undercrossing near Placerville, CA. Also reported are interfacial chemistry results for galvanized steel rebar from the 48 year old Longbird Bridge in Bermuda.

  18. Advanced modelling of concrete deterioration due to reinforcement corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Isgor, O.B. [Carleton Univ., Dept. of Civil and Environmental Engineering, Ottawa, Ontario (Canada); Razaqpur, A.G. [McMaster Univ., Dept. of Civil Engineering, Hamilton, Ontario (Canada)

    2006-06-15

    A comprehensive model is presented for predicting the rate of steel corrosion in concrete structures and the consequent formation and propagation of cracks around the steel reinforcement. The corrosion model considers both the initiation and the propagation stages of corrosion. Processes commencing in the initiation stage, such as the transport of chloride ions and oxygen within the concrete and variation in temperature and moisture, are assumed to continue in the propagation stage while active corrosion is occurring contemporaneously. This allows the model to include the effects of changes in exposure conditions on the corrosion rate and the effects of the corrosion reactions on the transport properties of concrete. The corrosion rates are calculated by applying the finite-element solution of the Laplace equation for electrochemical potential, with appropriate boundary conditions. Because these boundary conditions are nonlinear, a nonlinear solution algorithm is used. The results of the analysis are compared with available test data, and the comparison is found to be satisfactory. (author)

  19. ANALYSIS OF EXPOSURE OF REINFORCED CONCRETE BUILDINGS TO TEMPERATURE LOADS

    Directory of Open Access Journals (Sweden)

    Mkrtychev Oleg Vartanovich

    2012-10-01

    Full Text Available The co-authors consider the problem of analysis of building structures in respect of combined effects of forces and temperatures. Results of fire tests of reinforced concrete walls and slabs are presented. Overview of the analysis of the fire resistance of reinforced-concrete buildings is also provided. As a result of the research, numerical solutions were obtained in respect of deflections, stresses, deformations and internal forces arising in a reinforced concrete bearing wall and plate exposed to a combination of forces and thermal loads. Comparative analysis of the experimental data and the results of the numerical solution was performed. The conclusion is that the experimental data are in good fit to the results of the numerical solution. Overall limit state of the monolithic building under consideration in terms of its fire resistance means its failure as a result of collapse. The limit state value is equal to 60; therefore, it is equal to 60 minutes. This value, if considered in respect of separate bearing elements, fits the fire resistance limit of buildings of Grade III (Fire Resistance that is equal to 45. Evidently, assurance of higher fire resistance limits of the building under consideration requires special fire safety actions to be applied.

  20. Bond behaviour of GFRP reinforced geopolymer cement concrete

    Directory of Open Access Journals (Sweden)

    Hailu Tekle Biruk

    2017-01-01

    Full Text Available Bond plays a key role in the performance of reinforced concrete structures. Glass fibre reinforced polymer (GFRP reinforcing bar and Geopolymer cement (GPC concrete are promising alternative construction materials for steel bars and Ordinary Portland Cement (OPC concrete respectively. In this study, the bond behaviour between these two materials is investigated by using beam-end specimen tests. The bond behaviour of 15.9 mm diameter sand-coated GFRP bar was investigated. An embedment length of six and nine times the bar diameter were used. The free end and the loaded end bond-slip-relationships, the bond failure mode and the average bond stress were used to analyse each of the specimens. Additionally, the distribution of tensile and bond stress along the embedment length was investigated by installing strain gauges along the embedment length in some of the specimens. Test results indicate that a significant difference exists between the free end and loaded end bond-slip curves, which is due to the lower elastic modulus of the GFRP bars. Furthermore, it was found that the tensile and bond stress distribution along the embedment length is nonlinear and the nonlinearity changes with the load.

  1. Seismic Behaviour of Reinforced Concrete Slit Shear Walls Energy Dissipators

    Directory of Open Access Journals (Sweden)

    Sergiu Băetu

    2010-01-01

    Full Text Available The types of slit walls energy dissipators, from monolith or precast reinforced concrete, proposed by researchers and the seismic behaviour of these types of walls are described. The overall ductility of the structure increases, considering the energy dissipation solutions proposed by the researchers of the reinforced concrete walls, resulting a supplementary safety for the structure. The objective of these solutions is to create an ideal structure for tall multi-storey buildings, that behaves as a rigid structure at low seismic action and turns into a flexible one in case of a high intensity earthquake action. The solutions for increasing ductility proposed in this paper are viable and easily to use in constructions practice. For the analysis of slit wall, the researchers used a series of analytical calculation methods, among the most important being the equivalent frame method and the finite element method, both presented s. 3 of the paper. The researchers concluded that by using this calculations methods, the dynamic behaviour of the reinforced concrete slit walls can be simulated very accurate and realistic.

  2. Blast impact behaviour of concrete with different fibre reinforcement

    Directory of Open Access Journals (Sweden)

    Drdlová Martina

    2015-01-01

    Full Text Available The paper summarizes the results of the development of special concrete intended for the explosion resistance applications, with the emphasis on minimal secondary fragments formation at the explosion. The fine-grained concrete matrix has been reinforced by various types of short dispersed fibers (metallic, mineral and polymer of different sizes and by their combination and the effect of the fibre reinforcement on the physico-mechanical properties and blast resistance was observed. The concrete prism specimens have been subjected to the determination of mechanical parameters (compressive and flexural strength at quasi-static load. The blast tests were conducted on the slab specimens prepared from selected mixtures. The material characteristics and explosion test data have been used for numerical investigation, which defined the optimal wall composition and dimensions of the concrete element which should resist the explosion defined by type, size, weight and placement of the blast. In the next step the test elements resistance was verified by real explosion test.

  3. Cathodic protection of reinforced concrete structures in the Netherlands - Experience and developments: Cathodic protection of concrete - 10 years experience

    NARCIS (Netherlands)

    Polder, R.B.

    1998-01-01

    Cathodic protection (CP) of reinforcing steel in concrete structures has been used successfully for over 20 years. CP is able to stop corrosion in a reliable and economical way where chloride contamination has caused reinforcement corrosion and subsequent concrete damage. To new structures where cor

  4. Cathodic protection of reinforced concrete structures in the Netherlands - Experience and developments: Cathodic protection of concrete - 10 years experience

    NARCIS (Netherlands)

    Polder, R.B.

    1998-01-01

    Cathodic protection (CP) of reinforcing steel in concrete structures has been used successfully for over 20 years. CP is able to stop corrosion in a reliable and economical way where chloride contamination has caused reinforcement corrosion and subsequent concrete damage. To new structures where

  5. Performance of Sprayed Fiber Reinforced Polymer Strengthened Timber Beams

    Directory of Open Access Journals (Sweden)

    S. Talukdar

    2010-01-01

    Full Text Available A study was carried out to investigate the use of Sprayed Fiber Reinforced Polymer (SFRP for retrofit of timber beams. A total of 10-full scale specimens were tested. Two different timber preservatives and two different bonding agents were investigated. Strengthening was characterized using load deflection diagrams. Results indicate that it is possible to enhance load-carrying capacity and energy absorption characteristics using the technique of SFRP. Of the two types of preservatives investigated, the technique appears to be more effective for the case of creosote-treated specimens, where up to a 51% improvement in load-carrying capacity and a 460% increase in the energy absorption capacity were noted. Effectiveness of the bonding agent used was dependent on the type of preservative the specimen had been treated with.

  6. Shear Strengthening of Concrete Structures with the use of mineral based composites

    DEFF Research Database (Denmark)

    Blanksvärd, Thomas; Täljsten, Björn; Carolin, Anders

    2009-01-01

    Rehabilitation and strengthening of concrete structures have become more common during the last 10-15 years, partly due to a large stock of old structures and partly due to concrete deterioration. Also factors such as lack of understanding and the consequences of chloride attack affect the need f...

  7. 77 FR 71631 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-12-03

    ... COMMISSION Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine; Scheduling of Full Five-Year Reviews Concerning the Antidumping Duty Orders on Steel Concrete...) to determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from...

  8. 78 FR 73838 - Steel Concrete Reinforcing Bar From Turkey: Postponement of Preliminary Determination in the...

    Science.gov (United States)

    2013-12-09

    ... International Trade Administration Steel Concrete Reinforcing Bar From Turkey: Postponement of Preliminary... Department of Commerce (the Department) initiated a countervailing duty investigation on steel concrete... December 16, 2013.\\3\\ \\1\\ See Steel Concrete Reinforcing Bar from Turkey: Initiation of Countervailing Duty...

  9. Bond of reinforcing bars in self-compacting steel fiber reinforced concrete

    NARCIS (Netherlands)

    Schumacher, P.; Bigaj-van Vliet, A.J.; Braam, C.R.; Uijl, J.A. den; Walraven, J.C.

    2002-01-01

    Pull-out tests were performed on 10 mm diameter ribbed bars embedded along three times the bar diameter in 200 mm cubes made of plain and steel fiber reinforced concrete (SFRC) of normal strength (B45). The fiber content was 60 and 120 kg/m3, respectively, the aspect ratio of the fibers was 45 and 8

  10. Synergistic strengthening effect of nanocrystalline copper reinforced with carbon nanotubes.

    Science.gov (United States)

    Wang, Hu; Zhang, Zhao-Hui; Hu, Zheng-Yang; Wang, Fu-Chi; Li, Sheng-Lin; Korznikov, Elena; Zhao, Xiu-Chen; Liu, Ying; Liu, Zhen-Feng; Kang, Zhe

    2016-05-17

    In this study, a novel multi-walled carbon nanotubes reinforced nanocrystalline copper matrix composite with super high strength and moderate plasticity was synthesized. We successfully overcome the agglomeration problem of the carbon nanotubes and the grain growth problem of the nanocrystalline copper matrix by combined use of the electroless deposition and spark plasma sintering methods. The yield strength of the composite reach up to 692 MPa, which is increased by 2 and 5 times comparing with those of the nanocrystalline and coarse copper, respectively. Simultaneously, the plasticity of the composite was also significantly increased in contrast with that of the nanocrystalline copper. The increase of the density of the carbon nanotubes after coating, the isolation effect caused by the copper coating, and the improvement of the compatibility between the reinforcements and matrix as well as the effective control of the grain growth of the copper matrix all contribute to improving the mechanical properties of the composite. In addition, a new strengthening mechanism, i.e., the series-connection effect of the nanocrystalline copper grains introduced by carbon nanotubes, is proposed to further explain the mechanical behavior of the nanocomposite.

  11. Numerical Study of FRP Reinforced Concrete Slabs at Elevated Temperature

    Directory of Open Access Journals (Sweden)

    Masoud Adelzadeh

    2014-02-01

    Full Text Available One-way glass fibre reinforced polymer (GFRP reinforced concrete slabs at elevated temperatures are investigated through numerical modeling. Serviceability and strength requirements of ACI-440.1R are considered for the design of the slabs. Diagrams to determine fire endurance of slabs by employing “strength domain” failure criterion are presented. Comparisons between the existing “temperature domain” method with the more representative “strength domain” method show that the “temperature domain” method is conservative. Additionally, a method to increase the fire endurance of slabs by placing FRP reinforcement in two layers is investigated numerically. The amount of fire endurance gained by placing FRP in two layers increases as the thickness of slab increases.

  12. REVERSAL CYCLIC LOADING TEST OF REINFORCED CONCRETE COLUMN WITH HIGH DENSITY LONGITUDINAL REINFORCEMENT CONFINED BY SPIRAL REINFORCEMENT

    Science.gov (United States)

    Ohba, Mitsuaki; Sato, Akiko; Ishibashi, Tadayoshi

    In case of that column diameter is restricted by the narrow construction space, Concrete filled steel tube column is used. Authors developed new arrangement of bars that the range of longitudinal reinforcement ratio is from 14.8% to 24.7% and the longitudinal reinforcements are reinforced by spiral reinforcement. For the confirmation of the damage form and the deformation performance of the column with new bar arrangement at the earthquake, static reversal cyclic loading test was carried out. The parameters are longitudinal reinforcement ratio, shear span ratio and strength ratio. As the result, the damage form showed different trends due to longitudinal reinforcement ratio, shear span ratio and flexural strength and shear strength ratio. And specimens with the new bar arrangement had a good ductility with rotation angle of the column more than 1/10 and no rapid decline of strength. And, it is possible to evaluate ultimate bending capacity by considering the damage situation at maximum load.

  13. Theoretical and numerical analysis of reinforced concrete beams with confinement reinforcement

    Directory of Open Access Journals (Sweden)

    R. G. Delalibera

    Full Text Available This paper discusses the use of confinement in over-reinforced concrete beams. This reinforcement consists of square stirrups, placed in the compression zone of the beam cross-section, in order to improve its ductility. A parametric numerical study is initially performed, using a finite element computational program that considers the material nonlinearities and the confinement effect. To investigate the influence of the transverse reinforcing ratio on the beam ductility, an experimental program was also conducted. Four over-reinforced beams were tested; three beam specimens with additional transverse reinforcement to confine the beams, and one without it. All specimens were fabricated with a concrete designed for a compressive strength of 25 MPa. The experimental results show that the post-peak ductility factor is proportional to the confining reinforcement ratio, however the same is not observed for the pre-peak ductility factor, which varied randomly with changes in the confining reinforcement ratio. It was also observed from the experiments that the confinement effect tends to be smaller close to the beam neutral axis.

  14. Marine durability of 23-year old reinforced concrete beams

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, T. U. [NEWJEC Inc., Technology Development Dept., Osaka (Japan); Otsuki, N. [Tokyo Inst. of Technology (Japan); Hisada, M. [Niigata Univ., (Japan); Hamada, H. [Ministry of Transport, Port and Harbor Research Inst., Yokosuka (Japan)

    2000-07-01

    Results of a study concerning the durability of 23-year old reinforced concrete beams exposed to marine tidal and atmospheric environments are presented. The study focused on the corrosion of steel bars with respect to orientation in concrete, carbonation and chloride ion-induced corrosion, quantitative evaluation of electrochemical data and the influence of stirrups on macrocell formation. Experimental work included half cell potential, polarization resistance, solution resistance investigations, chloride ion profile and carbonation depth measurements, microscopic observations of steel-concrete interfaces, and visual inspection of steel bars corrosion. Results showed that chloride ion-induced corrosion was significantly influenced by the orientation of the steel bars in the concrete. Macrocell corrosion was found to be the governing process of corrosion in atmospheric environment, while stirrups played an important role in macrocell formation. Assuming the use of a suitable pit concentration, polarization data was considered to provide an acceptable, although inexact, estimate of the depth of corrosion. Peak chloride ion concentration was not observed at the concrete surface but at some distance below the surface, probably due to the effect of wetting and drying cycles. 8 refs., 9 tabs., 11 figs.

  15. Seismic retrofitting of reinforced concrete frame structures using GFRP-tube-confined-concrete composite braces

    Science.gov (United States)

    Moghaddasi B., Nasim S.; Zhang, Yunfeng; Hu, Xiaobin

    2012-03-01

    This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace, termed glass-fiber-reinforced-polymer (GFRP)-tube-confined-concrete composite brace, is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation. Together with a contribution from the GFRP-tube confined concrete, the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting. An analysis model is established and implemented in a general finite element analysis program — OpenSees, for simulating the load-displacement behavior of the composite brace. Using this model, a parametric study of the hysteretic behavior (energy dissipation, stiffness, ductility and strength) of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered. To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete (RC) frame structure was retrofitted with the composite braces. Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records. The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.

  16. Development of Flexible Link Slabs using Ductile Fiber Reinforced Concrete

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi

    emphasis oncrack formation and development at the rebar-matrix interface during direct tensile loading. Utilizing a high definition DIC technique in a novel approach, detailed measurements of the crack formation and debonding process are obtained. It is found that ductile ECC, in contrast to conventional...... two adjacent bridge deck segments. The link slab element, composed of GFRP reinforced ECC,exhibited the same tension stiffening and tension strengthening behavior with limited crack widths as was observed in the reinforced prisms under monotonic and cyclic loading. The combination of ductile ECC...

  17. Interface study of fiber reinforced concrete

    Directory of Open Access Journals (Sweden)

    Pacios, A.

    1997-12-01

    Full Text Available In a composite material that uses fibers as reinforcement, the breakage of the matrix is produced jointly with the separation of the fiber from the matrix. The mechanical behavior of the interface describes how fibers can work stabilizing the cracking process. The interface is the medium that puts the fiber on load, being the mechanical behavior of the interface and the strength of the fiber two important parameters to consider to characterize the general behavior of the composite. The present work studies the effect of several parameters on the behavior of the interface. Those parameters are the type of fiber, its geometry and dimension and the modified matrix and loading rate. An experimental technique was designed to allow testing the same set-up for pull-out tests in a quasistatic machine and Charpy pendulum. Modifications of the matrix by adding a mineral admixture improve the behavior of the interface as much as a 100%. It has been observed that combining the two actions, an improved matrix with crimped fibers, the type of failure can be modified. In this new type of failure, the fiber breaks consequently toughness decreases. Other parameters, as the loading rate and inclination of the fiber also affect the behavior of the interface.

    En un material compuesto que utiliza fibras como refuerzo, la rotura de la matriz se produce conjuntamente con la separación de la fibra de la matriz, por lo que el comportamiento mecánico de la interfase describe hasta que punto las fibras pueden trabajar como estabilizadores en el proceso defisuración. La interfase es el medio que pone en carga a la fibra y, por ello, la resistencia mecánica de la interfase y de la fibra son dos parámetros importantes a considerar para caracterizar el comportamiento general del composite. Este trabajo investiga el efecto de la variación del tipo de fibra, geometría y dimensión de las mismas y las modificaciones de la matriz y la velocidad de desplazamiento

  18. Improvement in reinforcing bond strength in reinforced concrete with self-repairing chemical adhesives

    Science.gov (United States)

    Dry, Carolyn M.

    1997-05-01

    Self-healing concretes have embedded adhesives which are released from hollow fibers inside the concrete when and where cracking of the matrix and the fibers occurs. It was found that the adhesive improves the strength of the cracked portions of the concrete and increases its ability to deflect under load. Structural materials subjected to dynamic events such as earthquakes and impacts can have improved response by the noise of adhesive type which can impart improved damping, lateral stiffness, or deflection. Testing also assessed the improvement of the bond strength in structures. In laboratory tests the internal adhesive repair system improved the bond between the reinforcing steel and the concrete to prevent pullout failure or debonding at the interface.

  19. Cost and Ductility Effectiveness of Concrete Columns Strengthened with CFRP and SFRP Sheets

    Directory of Open Access Journals (Sweden)

    Khaled Abdelrahman

    2014-05-01

    Full Text Available Recently, steel fibre reinforced polymers (SFRP sheets have been introduced for the repair and rehabilitation of concrete structures. Few researchers studied the behaviour of the concrete columns wrapped with SFRP sheets; however, several critical parameters such as the cost and ductility effectiveness of the SFRP wrapped concrete columns have been lightly addressed. Thus, the main objective of this paper is to study the cost and ductility effectiveness of SFRP wrapped concrete columns and compare the results with the conventionally used carbon FRP (CFRP wrapped concrete columns. In addition, an analytical procedure to predict the cost effectiveness of SFRP wrapped concrete columns is also suggested, from which, a parametric study was conducted. The parametric study investigated the effect of the concrete strength, the number of SFRP layers, and the size and slenderness effects on the cost effectiveness of the concrete columns wrapped with SFRP sheets. The results from the cost and ductility effectiveness study indicated that the SFRP wrapped concrete columns showed enhanced performance over the CFRP wrapped concrete columns. The suggested analytical procedure proved to be a reliable and accurate method to predict the cost effectiveness parameter of SFRP wrapped concrete columns. The parametric study showed the significant impact of the investigated parameters on the cost effectiveness of concrete columns wrapped with SFRP sheets.

  20. Resistance of reinforced concrete beams in explosive charges

    Directory of Open Access Journals (Sweden)

    Roman Krzewiński

    2016-12-01

    Full Text Available The paper presents an analysis of the dynamic interaction on reinforced concrete beams, caused by the outbreak of not-direct contact with the design. Depending on the distance of the source of the outbreak, the structure may be loaded with gas stream postexplosion or air shock wave. The impact of such influence on the reinforced concrete beam of a constant cross-section and small transverse dimensions compared with their length was assessed. For the beams located in the closer zone, there were evaluated the parameters of the destructive action of explosions limit case, in which the concrete chipping occurs at a length of at least the length of the buckling of steel rods. In case of loading of beams with air shock wave, using literature data, they determined the way of evaluating equivalent static load at which the boundary elastic deflection of beams occurs. The above analysis is shown by the example calculation, which sets the minimum length of the buckling of steel bars in the beam bending.[b]Keywords:[/b] civil engineering, the dynamics of the explosion, the noncontact loads, dynamic loads, reflectance

  1. Enhancement of shear strength and ductility for reinforced concrete wide beams due to web reinforcement

    Directory of Open Access Journals (Sweden)

    M. Said

    2013-12-01

    Full Text Available The shear behavior of reinforced concrete wide beams was investigated. The experimental program consisted of nine beams of 29 MPa concrete strength tested with a shear span-depth ratio equal to 3.0. One of the tested beams had no web reinforcement as a control specimen. The flexure mode of failure was secured for all of the specimens to allow for shear mode of failure. The key parameters covered in this investigation are the effect of the existence, spacing, amount and yield stress of the vertical stirrups on the shear capacity and ductility of the tested wide beams. The study shows that the contribution of web reinforcement to the shear capacity is significant and directly proportional to the amount and spacing of the shear reinforcement. The increase in the shear capacity ranged from 32% to 132% for the range of the tested beams compared with the control beam. High grade steel was more effective in the contribution of the shear strength of wide beams. Also, test results demonstrate that the shear reinforcement significantly enhances the ductility of the wide beams. In addition, shear resistances at failure recorded in this study are compared to the analytical strengths calculated according to the current Egyptian Code and the available international codes. The current study highlights the need to include the contribution of shear reinforcement in the Egyptian Code requirements for shear capacity of wide beams.

  2. Failure mode classification of reinforced concrete column using Fisher method

    Institute of Scientific and Technical Information of China (English)

    戚永乐; 韩小雷; 季静

    2013-01-01

    In order to apply the performance-based seismic design, an engineer must first find out whether the column is expected to fail in shear before or after flexural yielding. According to column failure characteristics and failure mode of reinforced concrete column, the UW-PEER structure performance database was discussed and analyzed. In order to investigate the relevance of failure mode and factors such as longitudinal reinforcement ratio, transverse reinforcement ratio, hoop spacing to depth ratio, aspect ratio, shearing resistance demand to shear capacity ratio and axial load ratio, Fisher’s discriminant analysis(FDA) of the above factors was carried out. A discriminant function was developed to identify column failure mode. Results show that three factors, i.e., Vp /Vn, hoop spacing to depth ratio and aspect ratio have important influence on the failure mode. The failure mode has less to do with longitudinal reinforcement ratio, transverse reinforcement ratio and axial load ratio. Through using these three factors and the model proposed, over 85.6% of the original grouped cases were correctly classified. The value of coefficient of Vp /Vn is the largest, which means that discriminant equation is most sensitive to the shearing resistance demand to shear capacity ratio.

  3. Correlations Between Mechanical Properties of Steel Fiber Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Carrillo Julián

    2013-06-01

    Full Text Available Tension strength and post-cracking deformation capacities that exhibits steel fiber reinforced concrete (SFRC stimulate its use in elements governed by shear deformations. Aimed at developing design aids that promote the use of SFRC as web shear reinforcement of concrete walls for low-rise economic housing (LEH, an experimental study for describing the mechanical properties of SFRC was carried out. The experimental program included testing of 128 cylinder- and beam-type specimens. According to requirements specified by ACI-318, to thickness of walls used in LEH, and to results of previous studies, three Dramix fibers with length-diameter ratios of 55, 64 and 80 were selected. Fiber dosage was expressed in terms of the minimum fiber dosage specified by ACI-318 for replacing the minimum area of conventional shear reinforcement in beams (60 kg/m3. Therefore, five dosages were used: 0, 40, 45, 60 and 75 kg/m3. Mechanical properties of SFRC under compressive, tensile and flexural stresses were evaluated in this study. Based on trends of experimental results, numerical correlations for estimating both basic mechanical properties and properties that describe flexural performance of SFRC are proposed.

  4. Evaluation of Concrete Consolidation: DSS-35 Antenna Reinforced Concrete Pedestal, Canberra Deep Space Communications Complex, Australia

    Science.gov (United States)

    Saldua, B. P.; Dodge, E. C.; Kolf, P. R.; Olson, C. A.

    2016-02-01

    Antenna structures for the Deep Space Network track spacecraft that are millions of miles away. Therefore, these structures have tight specifications for translation, rotation, and differential settlement. This article presents several nondestructive test methods that were used to evaluate, locate, and repair imperfections in the reinforced concrete pedestal that supports the DSS-35 antenna structure. These methods include: (1) impulse response (IR), (2) ultrasonic shear-wave tomography (MIRA), and (3) ground-penetrating radar (GPR).

  5. Neural Network Model for Moment-Curvature Relationship of Reinforced Concrete Sections

    OpenAIRE

    Bağcı, Muhiddin

    2010-01-01

    The analysis of moment-curvature relationship of reinforced concrete sections is complex due to large number of variables as well as non-linear material behavior involved. Artificial Neural Networks (ANNs) are found to be a tool capable of solving such problems. This has led to increasing use of ANN for analyzing the behavior of reinforced concrete sections. This paper reports the details of a study conducted using ANN for predicting moment-curvature relationship of a reinforced concrete sect...

  6. NATURAL CORROSION INHIBITORS FOR STEEL REINFORCEMENT IN CONCRETE — A REVIEW

    OpenAIRE

    PANDIAN BOTHI RAJA; SEYEDMOJTABA GHOREISHIAMIRI; MOHAMMAD ISMAIL

    2015-01-01

    Reinforced concrete is one of the widely used construction materials for bridges, buildings, platforms and tunnels. Though reinforced concrete is capable of withstanding a large range of severe environments including marine, industrial and alpine conditions, there are still a large number of failures in concrete structures for many reasons. Either carbonation or chloride attack is the main culprit which is due to depassivation of reinforced steel and subsequently leads to rapid steel corrosio...

  7. CALCULATION ASSESSMENT OF ANCHORAGE IN CONCRETE FOR FIBERGLASS REINFORCEMENT MANUFACTURED IN THE REPUBLIC OF BELARUS

    Directory of Open Access Journals (Sweden)

    E. Ya. Sadin

    2016-01-01

    Full Text Available The paper analyzes advantages and disadvantages of composite reinforcement while reinforcing concrete structures. Results of experimental investigations on adhesion strength of fiberglass reinforcement manufactured in the Republic of Belarus with concrete have been given in the paper. The paper contains an analysis pertaining to the influence of concrete contact diameter and length of fiberglass reinforcing bars on strength and deformability of adhesion with concrete. Failure behavior of prototypes and maximum loading that does cause breakage in adhesion of fiberglass reinforcement with the concrete have been controlled in order to study the influence of diameter and length of fiberglass reinforcing bar contact with the concrete on strength and deformability of concrete adhesion for composite reinforcement produced by various manufacturers. Displacement of non-loaded (free and loaded ends of the reinforcing bars with regard to concrete exposed face on both specimen ends has been also controlled. The experiments have shown that destruction of the prototypes occurred due to initiation of one of the following three reasons: reinforcement sliding in reference to concrete, cleaving of a protective concrete layer or breakage of composite reinforcement. Start-up moments for reinforcing bar slip in relation to the concrete have been determined with the help of two methods. The paper provides proposals for calculation assessment of anchorage in the concrete for fiberglass reinforcement manufactured by the following enterprises and companies “Stroykompozit” (Gomel, Republic of Belarus, Research and Production Company (RPC “Biznes-Kontinent” (Brest, Republic of Belarus and Private Eenterprise (PE “Minplast” (Minsk, Republic of Belarus.

  8. Investigation on Reinforced Mechanism of Fiber Reinforced Asphalt Concrete Based on Micromechanical Modeling

    Directory of Open Access Journals (Sweden)

    Ying Gao

    2017-01-01

    Full Text Available Short fibers have been widely used to prepare the fiber reinforced asphalt concrete (FRAC. However, internal interactions between fiber and other phases of asphalt concrete are unclear although experimental methods have been used to design the FRAC successfully. In this paper, numerical method was used to investigate the reinforced mechanism of FRAC from microperspective. 2D micromechanical model of FRAC was established based on Monte Carlo theory. Effects of fiber length and content on stress state of asphalt mortar, effective modulus, and viscoelastic deformation of asphalt concrete were investigated. Indirect tensile stiffness modulus (ITSM test and uniaxial creep test were carried out to verify the numerical results. Results show that maximum stress of asphalt mortar is lower compared to the control concrete when the fiber length is longer than 12 mm. Fiber reduces the stress level of asphalt mortar significantly. Fiber length has no significant influence on the effective modulus of asphalt concrete. Fiber length and content both have notable impacts on the viscoelastic performance of FRAC. Fiber length should be given more attention in the future design of FRAC except the content.

  9. Green Plant Extract as a passivationpromoting Inhibitor for Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Abdulrahman A. S.

    2011-08-01

    Full Text Available The present corrosion inhibitors in market for the protection of steel reinforcement in concrete exposed to chloride attack are toxic to the environment and compromises sustainability drives. There is the needs to develop inhibitor that are eco-friendly and sustainable. In this work the ability of hydrophobic green plant extracts inhibitor (Bambusa arundinacea to repassivates the chloride induced corrosion of steel was studied. Its efficacy and effectiveness was also compared with calcium nitrite inhibitor. Concrete mix was designed to 30MPa with 0.45 W/C ratios and 1.5% weight of cement content of chloride was added to initiate corrosion.Inhibitors additions were 2%. Electrochemical impedance spectroscopy, linear polarization resistance and Field emission spectroscopy (FESEM were used to monitor corrosion behavior of steel at 180 days exposure period. Corrosion rate of the inhibitors studied showed that Bambusa Arundinacea is superior as compared to calcium nitrite as results of its high concrete resistivity, chloride binding property and polarization resistance. Bambusa Arundinacea may be considered a better substitute for nitrite based corrosion inhibiting admixtures for durable concrete structures due its versatility.

  10. The effects of steel fibre reinforced concrete on system ductility

    Directory of Open Access Journals (Sweden)

    Yilmaz, U. S.

    2007-03-01

    Full Text Available Steel fibre-reinforced concrete is being used extensively today in both field applications and experimental studies on concrete strength and ductility. The state of passive confinement generated by the fibre delays cracking and enhances ductility. The present paper reports on both experimental and analytical studies. In the former, a series of 16 steel-fibre reinforced concrete prismatic specimens were subjected to axial loads and the respective axial load-unit strain diagrams were subsequently plotted to determine the effect of steel fibres on reinforced concrete column ductility. Secondly, an analytical study was run to determine the additional ductility accruing to a frame system when steel fibres are included in the concrete. Analytical models were generated for 16 two-storey, single-span reinforced concrete frames. The columns in these frames were designed to the same characteristics as the specimens used in the experimental tests. Non-linear static (pushover analyses were performed for each frame to obtain load-displacement curves and determine the effect of steel fibres on reinforced concrete column ductility.El hormigón reforzado con fibra de acero se emplea actualmente tanto en obra como en los trabajos experimentales para estudiar la resistencia mecánica y ductilidad del hormigón. El estado de confinamiento pasivo producido por la fibra retrasa la fisuración y aumenta la ductilidad. El presente trabajo es de índole tanto experimental como analítica. En primer lugar, en la parte experimental se aplica una fuerza axial a 16 probetas prismáticas (160 x 160 x 840 mm de hormigón reforzado con fibra de acero para determinar su comportamiento, obteniéndose las curvas de fuerza axial-deformación unitaria correspondientes a partir de los resultados observados. A partir de una evaluación de dichos resultados experimentales, se determina el efecto que ejercen las fibras de acero sobre la ductilidad de las probetas de hormigón armado

  11. Flexural Strength Evaluation of Reinforced Concrete Members with Ultra High Performance Concrete

    Directory of Open Access Journals (Sweden)

    Baek-Il Bae

    2016-01-01

    Full Text Available Flexural strength evaluation models for steel fiber reinforced ultra high strength concrete were suggested and evaluated with test results. Suggested flexural strength models were composed of compression stress blocks and tension stress blocks. Rectangular stress block, triangular stress block, and real distribution shape of stress were used on compression side. Under tension, rectangular stress block distributed to whole area of tension side and partial area of tension side was used. The last model for tension side is realistic stress distribution. All these models were verified with test result which was carried out in this study. Test was conducted by four-point loading with 2,000 kN actuator for slender beam specimen. Additional verifications were carried out with previous researches on flexural strength of steel fiber reinforced concrete or ultra high strength concrete. Total of 21 test specimens were evaluated. As a result of comparison for flexural strength of section, neutral axis depth at ultimate state, models with triangular compression stress block, and strain-softening type tension stress block can be used as exact solution for ultra high performance concrete. For the conservative and convenient design of section, modified rectangular stress block model can be used with strain softening type tension stress block.

  12. Durability Studies on Confined Concrete using Fiber Reinforced Polymer

    Science.gov (United States)

    Ponmalar, V.; Gettu, R.

    2014-06-01

    In this study, 24 concrete cylinders with a notch at the centre were prepared. Among them six cylinders were wrapped using single and double layers of fiber reinforced polymer; six cylinders were coated with epoxy resin; the remaining cylinders were used as a control. The cylinders were exposed to wet and dry cycling and acid (3 % H2SO4) solution for the period of 120 days. Two different concrete strengths M30 and M50 were considered for the study. It is found that the strength, ductility and failure mode of wrapped cylinders depend on number of layers and the nature of exposure conditions. It was noticed that the damage due to wet and dry cycling and acid attack was severe in control specimen than the epoxy coated and wrapped cylinders.

  13. Fatigue Defect of Layer Steel Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    An experimental study is carried out on fatigue defect of layer steel fiber reinforced concrete (LSFRC). Based on experimental data,the various relation curves are given corresponding to different stress levels 0.9, 0.85, and 0.8. Furthermore, the fatigue defect degree is defined, and the strain-cycle ratio equations and defect-cycle ratio equations with the correlation coefficients very close to 1, are regressed in terms of the cubic polynomial,of which the fittings are preferable.In addition,the results show that the fatigue defect of LSFRC presents three-phase development regularity too.And in comparison with the plain concrete,the third phase of the fatigue defect of LSFRC is longer, therefore the fatigue failure of LSFRC is more ductile.The mechanism of the fatigue defect is discussed too.

  14. Analysis of reinforced concrete shells with transverse shear forces

    CERN Document Server

    Schulz, Mauro

    2013-01-01

    This research investigates the simultaneous effect of in-plane and transverse loads in reinforced concrete shells. The infinitesimal shell element is divided into layers (with triaxial behavior) that are analyzed according to the smeared rotating crack approach. The set of internals forces includes the derivatives of the in-plane components. The corresponding generalized strains are determined using an extension of the equivalent section method, valid for shells. The formulation yields through-the-thickness distributions of stresses and strains and the spatial orientation of the concrete struts. Although some simplifications are necessary to establish a practical first-order approximation, higher-order solutions could be developed. Despite the fact that constitutive matrices are not symmetric, because of the tension-softening formulation, the equilibrium and compatibility conditions are satisfied, the stiffness derivatives are explicitly calculated and the algorithms show good convergence. The formulation pre...

  15. Corrosion of steel reinforced concrete in the tropical coastal atmosphere of Havana City, Cuba

    Directory of Open Access Journals (Sweden)

    Abel Castañeda

    2013-01-01

    Full Text Available The influence of chloride deposition rate on concrete using an atmospheric corrosion approach is rarely studied in the literature. Seven exposure sites were selected in Havana City, Cuba, for exposure of reinforced concrete samples. Two significantly different atmospheric corrosivity levels with respect to corrosion of steel reinforced concrete were observed after two years of exposure depending on atmospheric chloride deposition and w/c ratio of the concrete. Changes in corrosion current are related to changes in chloride penetration and chloride atmospheric deposition. The influence of sulphur compound deposition could also be a parameter to consider in atmospheric corrosion of steel reinforced concrete.

  16. Micro-Mechanical Modeling of Fiber Reinforced Concrete

    DEFF Research Database (Denmark)

    Stang, Henrik

    1999-01-01

    of Fiber Reinforced Concrete (FRC) on the micro- the meso- as well as the macro-level, i.e. modeling aspects of fiber-matrix interaction, overall constitutive modeling and structural modeling. Emphasis is placed on the micro- and meso-aspects, however, some basic results on the macro-level are also......The paper is a contribution to the course Cement-Based Composites for the Building Industry, organized by POA Foundation for Postgraduate Studies in Civil Engineering in cooperation with Priority Programme Material Research (PPM) in the Netherlands. The text deals with mechanical modeling aspects...

  17. Design of Ultra High Performance Fiber Reinforced Concrete Shells

    DEFF Research Database (Denmark)

    Jepsen, Michael S.; Lambertsen, Søren Heide; Damkilde, Lars

    2013-01-01

    Fiber Reinforced Concrete shell. The major challenge in the design phase has been securing sufficient stiffness of the structure while keeping the weight at a minimum. The weight/stiffness issue has been investigated by means of the finite element method, to optimize the structure regarding overall......The paper treats the redesign of the float structure of the Wavestar wave energy converter. Previously it was designed as a glass fiber structure, but due to cost reduction requirements a redesign has been initiated. The new float structure will be designed as a double curved Ultra High Performance...

  18. STUDIES ON STRESS TRANSFERENCE MECHANISM OF STEEL FIBRE REINFORCED CONCRETE

    Institute of Scientific and Technical Information of China (English)

    杨佑发; 许绍乾; 钟正华

    2001-01-01

    The stress transfer mechanism of steel fibre reinforced concrete is studied. The solutions for the stress and displacement were regarded as the superposition of "the elementary solutions" and "the improved solutions". The elementary solutions were found by using two-dimensional elastic theory and the improved solutions were found by using the Love displacement function method. The calculated results indicate that the solutions possess good convergence. By comparing the three-dimensional solutions with the shear-lag solutions, evident difference may be found.

  19. EXPERIMENTAL RESEARCH OF EFFICIENCY OF DISPERSE REINFORCEMENT OF STRETCHED ZONE OF FLEXURAL CONCRETE ELEMENTS

    OpenAIRE

    V. S. Izotov, R. Kh. Mukhametrakhimov, L. S. Sаbitov

    2011-01-01

    Problem statement. The method of disperse reinforcement of flexural concrete elements by fiber introduction in concrete stretched zone is described.Results and conclusions. The method provides more efficient use and economy of disperse rein-forcement, materials consumption reduction at the maintenance of specified flexural strength, high impact elasticity, and fracture strength. The comparative assessment of disperse reinforcement efficiency for two types of metal fibers is given at reinforce...

  20. Assessment of concrete damage and strength degradation caused by reinforcement corrosion

    Science.gov (United States)

    Nepal, Jaya; Chen, Hua-Peng

    2015-07-01

    Structural performance deterioration of reinforced concrete structures has been extensively investigated, but very limited studies have been carried out to investigate the effect of reinforcement corrosion on time-dependent reliability with consideration of the influence of mechanical characteristics of the bond interface due to corrosion. This paper deals with how corrosion in reinforcement creates different types of defects in concrete structure and how they are responsible for the structural capacity deterioration of corrosion affected reinforced concrete structures during their service life. Cracking in cover concrete due to reinforcement corrosion is investigated by using rebar-concrete model and realistic concrete properties. The flexural strength deterioration is analytically predicted on the basis of bond strength evolution due to reinforcement corrosion, which is examined by the experimental data available. The time-dependent reliability analysis is undertaken to calculate the life time structural reliability of corrosion damaged concrete structures by stochastic deterioration modelling of reinforced concrete. The results from the numerical example show that the proposed approach is capable of evaluating the damage caused by reinforcement corrosion and also predicting the structural reliability of concrete structures during their lifecycle.

  1. Application of Bond-Slip in the Finite Element Analyses of Reinforced Concrete Shear Walls

    Directory of Open Access Journals (Sweden)

    İlker Kazaz

    2012-03-01

    Full Text Available Transfer of tensile forces from reinforcing steel into the surrounding concrete affects the behavior of reinforced concrete members. This transfer relies on the bond action between the steel and the concrete. Under monotonic loading the part of bond strength due to chemical adhesion is easily exhausted and bearing against the lugs is the primary load-transfer mechanism at loads near the ultimate. These stresses cause internal cracking of concrete at the steel-concrete interface. This paper deals with the finite element modeling of the bond-slip and its application due to internal cracking of the first layer of concrete surrounding the bar and the bending and/ or cracking of the small concrete teeth near the bar lugs. A previously proposed constitutive steel stress-bond slip relation by Mirza and Houde (1979 was used in finite element analysis of reinforced concrete shear wall specimens and the results were presented.

  2. Topology optimization of reinforced concrete beams by a spread-over reinforcement model with fixed grid mesh

    Directory of Open Access Journals (Sweden)

    Benjapon Wethyavivorn

    2011-02-01

    Full Text Available For this investigation, topology optimization was used as a tool to determine the optimal reinforcement for reinforcedconcrete beam. The topology optimization process was based on a unit finite element cell with layers of concrete and steel.The thickness of the reinforced steel layer of this unit cell was then adjusted when the concrete layer could not carry thetensile or compressive stress. At the same time, unit cells which carried very low stress were eliminated. The process wasperformed iteratively to create a topology of reinforced concrete beam which satisfied design conditions.

  3. Nondestructive evaluation of dissipative behavior of reinforced concrete structure

    Energy Technology Data Exchange (ETDEWEB)

    Luong, M.P. [Ecole Polytechnique, LMS, CNRS, 91 - Palaiseau (France)

    2001-07-01

    Current technological developments tend toward increased exploitation of materials strengths and toward tackling extreme loads and environmental actions such as offshore structures subject to wind and wave loading, or buildings in seismic area. Concrete is widely used as a construction material because of its high strength-cost ratio in many applications. Experience of earthquakes and laboratory tests has shown that well designed and detailed reinforced concrete is suitable for earthquake resistant structures. The most severe likely earthquake can be survived if the members are sufficiently ductile to absorb and dissipate seismic energy by inelastic deformation. This requires a designer to assess realistically the acceptable levels of strength and to ensure adequate dissipation. This paper proposes the use of infrared thermography as a nondestructive, noncontact and real-time technique to examine diverse mechanisms of dissipation and to illustrate the onset of damage process, stress concentration and heat dissipation localization in loaded zone. In addition, this technique can be used as a nondestructive method for evaluating the fatigue limit of concrete structure subject to repeated loading.

  4. Temperature effects on bond between concrete and reinforcing steel

    Directory of Open Access Journals (Sweden)

    Lublóy Éva

    2014-01-01

    Full Text Available Bond behaviour between concrete and reinforcing bars was observed under elevated temperatures. Five different concrete compositions were used. Hundred five pull-out specimens (Ø120 mm, 100 mm were prepared. After removing the specimens from the formwork, they were stored in water for seven days then kept at laboratory conditions until testing. The specimens were 28 days old by testing. After heating up the specimens, they were kept for two hours at these maximum temperatures (20 °C, 150 °C, 300 °C, 400 °C, 500 °C, 800 °C. Specimens were then cooled down in laboratory conditions. Finally the specimens were tested at room temperature. In order to check the compressive strength standard cubes were cast, cured, and heat treated, then tested to compressive strength. The results showed reduction in residual compressive strength and considerable changes in steel-concrete bond under high temperatures. Based on test results, a proposal is presented for the modification of MC2010 bond-ship formula in order to consider temperature effect.

  5. Shear Strength of Reinforced Concrete Beams Under Sea Water

    Institute of Scientific and Technical Information of China (English)

    阎西康; 王铁成; 张玉敏

    2004-01-01

    The marine structures such as harbour,pier and inshore concrete terrace are exposed in adverse circumstances in a long period of time . Owing to the attack of external corrosive medium, their safety, durability and reliability decline. Especially the reinforced concrete(RC) structures in the wave splash area are more likely to be subjected to destruction and the loss is vast. Now the safety ,durability and reliability of structure have become increasingly an important subject to be studied. By way of the soaking and drying cycle test on the different mix proportions oblique section of 10 pieces of RC beams suffered artificial sea water(ASW) corrosion under 0,35,70,105,140 times of dry-wet cycles ,the compared results of exerting pressure test of these beams under simply supporting were investigated. The law about the changes of the mechanical performance for RC beams with different mix proportions under different time periods for suffering corrosion of dry-wet cycles is as follows: the resistivity to ASW corrosion of the concrete specimens with various water cement ratio( various initial strength) is different; the characters of oblique section failure for RC beams attacked by sea water are about the same as those for ordinary RC beam; along with the extension of the time for sea water attack, the bearing capacity for oblique section of RC beams varies wave upon wave. The specimens attacked by sea water for about 35 times of corrosion cycle achieve minimum bearing capacity.

  6. Earthquake Response of Reinforced Concrete Building Retrofitted with Geopolymer Concrete and X-shaped Metallic Damper

    Science.gov (United States)

    Madheswaran, C. K.; Prakash vel, J.; Sathishkumar, K.; Rao, G. V. Rama

    2017-06-01

    A three-storey half scale reinforced concrete (RC) building is fixed with X-shaped metallic damper at the ground floor level, is designed and fabricated to study its seismic response characteristics. Experimental studies are carried out using the (4 m × 4 m) tri-axial shake-table facility to evaluate the seismic response of a retrofitted RC building with open ground storey (OGS) structure using yielding type X-shaped metallic dampers (also called as Added Damping and Stiffness-ADAS elements) and repairing the damaged ground storey columns using geopolymer concrete composites. This elasto-plastic device is normally incorporated within the frame structure between adjacent floors through chevron bracing, so that they efficiently enhance the overall energy dissipation ability of the seismically deficient frame structure under earthquake loading. Free vibration tests on RC building without and with yielding type X-shaped metallic damper is carried out. The natural frequencies and mode shapes of RC building without and with yielding type X-shaped metallic damper are determined. The retrofitted reinforced concrete building is subjected to earthquake excitations and the response from the structure is recorded. This work discusses the preparation of test specimen, experimental set-up, instrumentation, method of testing of RC building and the response of the structure. The metallic damper reduces the time period of the structure and displacement demands on the OGS columns of the structure. Nonlinear time history analysis is performed using structural analysis package, SAP2000.

  7. Optimization of the Infrastructure of Reinforced Concrete Reservoirs by a Particle Swarm Algorithm

    Science.gov (United States)

    Kia, Saeed; Sebt, Mohammad Hassan; Shahhosseini, Vahid

    2015-03-01

    Optimization techniques may be effective in finding the best modeling and shapes for reinforced concrete reservoirs (RCR) to improve their durability and mechanical behavior, particularly for avoiding or reducing the bending moments in these structures. RCRs are one of the major structures applied for reserving fluids to be used in drinking water networks. Usually, these structures have fixed shapes which are designed and calculated based on input discharges, the conditions of the structure's topology, and geotechnical locations with various combinations of static and dynamic loads. In this research, the elements of reservoir walls are first typed according to the performance analyzed; then the range of the membrane based on the thickness and the minimum and maximum cross sections of the bar used are determined in each element. This is done by considering the variable constraints, which are estimated by the maximum stress capacity. In the next phase, based on the reservoir analysis and using the algorithm of the PARIS connector, the related information is combined with the code for the PSO algorithm, i.e., an algorithm for a swarming search, to determine the optimum thickness of the cross sections for the reservoir membrane's elements and the optimum cross section of the bar used. Based on very complex mathematical linear models for the correct embedding and angles related to achain of peripheral strengthening membranes, which optimize the vibration of the structure, a mutual relation is selected between the modeling software and the code for a particle swarm optimization algorithm. Finally, the comparative weight of the concrete reservoir optimized by the peripheral strengthening membrane is analyzed using common methods. This analysis shows a 19% decrease in the bar's weight, a 20% decrease in the concrete's weight, and a minimum 13% saving in construction costs according to the items of a checklist for a concrete reservoir at 10,000 m3.

  8. Shear crack propagation in MBC strengthened concrete beams”

    DEFF Research Database (Denmark)

    Täljsten, Björn; Blanksvärd, Thomas; Carolin, Anders

    2008-01-01

    study of MBC systems. Emphasis is placed on the cracking behavior of the MBC system used for shear strengthening of RC beams. Traditional foil strain gauges and photometric measurements have been used for monitoring of the cracking behavior. In this study it is shown that the use of mineral based shear...

  9. 初始荷载对RC梁碳纤维布抗弯加固效果影响的有限元分析%Finite-element Analysis of Effect of Initial Load on Bending Capacity of Reinforced Concrete Beam Strengthened with CFRP

    Institute of Scientific and Technical Information of China (English)

    武志杰; 陈悦

    2013-01-01

    利用ANSYS建立14根碳纤维布加固钢筋混凝土简支梁模型,分析在两种配筋率情况下,不同初始荷载对钢筋混凝土梁碳纤维布抗弯加固效果的影响。结果表明:碳纤维布加固可显著提高梁的屈服荷载和极限荷载,梁的屈服荷载和极限荷载的提高幅度随着初始荷载的增加而减小;配筋率越小,受拉钢筋利用越充分,梁的极限荷载提高幅度越明显。%Fourteen reinforced concrete simply supported beam models with CFRP sheets were built by using ANSYS, and the influence of different initial loads on the reinforcement and flexural strength effects of CFRP sheets in two steel rein-forcement ratios was analyzed. The results indicated that reinforced carbon fiber sheet could significantly increase the yield-ing load and ultimate load of the beam. The enhancement of yielding load and ultimate load decreased with the increase of initial load. The more adequate the steel reinforcement utilization rate was, the more significantly the ultimate load with small reinforcement ratio would be improved.

  10. Non-traditional shape GFRP rebars for concrete reinforcement

    Science.gov (United States)

    Claure, Guillermo G.

    The use of glass-fiber-reinforced-polymer (GFRP) composites as internal reinforcement (rebars) for concrete structures has proven to be an alternative to traditional steel reinforcement due to significant advantages such as magnetic transparency and, most importantly, corrosion resistance equating to durability and structural life extension. In recent years, the number of projects specifying GFRP reinforcement has increased dramatically leading the construction industry towards more sustainable practices. Typically, GFRP rebars are similar to their steel counterparts having external deformations or surface enhancements designed to develop bond to concrete, as well as having solid circular cross-sections; but lately, the worldwide composites industry has taken advantage of the pultrusion process developing GFRP rebars with non-traditional cross-sectional shapes destined to optimize their mechanical, physical, and environmental attributes. Recently, circular GFRP rebars with a hollow-core have also become available. They offer advantages such as a larger surface area for improved bond, and the use of the effective cross-sectional area that is engaged to carry load since fibers at the center of a solid cross-section are generally not fully engaged. For a complete understanding of GFRP rebar physical properties, a study on material characterization regarding a quantitative cross-sectional area analysis of different GFRP rebars was undertaken with a sample population of 190 GFRP specimens with rebar denomination ranging from #2 to #6 and with different cross-sectional shapes and surface deformations manufactured by five pultruders from around the world. The water displacement method was applied as a feasible and reliable way to conduct the investigation. In addition to developing a repeatable protocol for measuring cross-sectional area, the objectives of establishing critical statistical information related to the test methodology and recommending improvements to

  11. Mechanical Behavior of Rectangular Steel-Reinforced ECC/Concrete Composite Column under Eccentric Compression

    Institute of Scientific and Technical Information of China (English)

    潘金龙; 鲁冰; 顾大伟; 夏正昊; 夏天阳

    2015-01-01

    In order to improve the seismic performance, deformation ability and ultimate load-carrying capacity of columns with rectangular cross section, engineered cementitious composite (ECC) is introduced to partially substitute concrete in the edge zone of reinforced concrete columns and form reinforced ECC/concrete composite columns. Firstly, based on the assumption of plane remaining plane and the simplified constitutive models, the calculation method of the load-carrying capacity of reinforced ECC/concrete columns is proposed. The stress and strain distribu-tions and crack propagation of the composite columns in different states of eccentric compressive loading are ana-lyzed. Then, nonlinear finite element analysis is conducted to study the mechanical performance of reinforced ECC/concrete composite columns with rectangular cross section. It is found that the simulation results are in good agreement with the theoretical results, indicating that the proposed method for calculating the load-carrying capacity of concrete/ECC composite columns is valid. Finally, based on the proposed method, the effects of ECC thickness, com-pressive strength of concrete and longitudinal reinforcement ratio on the mechanical performance of reinforced ECC/concrete composite columns are analyzed. Calculation results indicate that increasing the thickness of ECC layer or longitudinal reinforcement ratio can effectively increase the ultimate load-carrying capacity of the composite column with both small and large eccentricity, but increasing the strength of concrete can only increase the ultimate load-carrying capacity of the composite column with small eccentricity.

  12. The Shrinkage Cracking Behavior in Reinforced Reactive Powder Concrete Walls

    Directory of Open Access Journals (Sweden)

    Samir A. Al-Mashhadi

    2017-07-01

    Full Text Available In this study, the reduced scale wall models were used (they are believed to resemble as much as possible the field conditions to study the shrinkage behavior of reactive powder concrete (RPC base restrained walls. Six base restrained RPC walls were casted in different length/height ratios of two ratios of steel fiber by volume in Summer. These walls were restrained by reinforced concrete bases to provide the continuous base restraint to the walls. The mechanical properties of reactive powder concrete investigated were; compressive strength between (75.3 – 140.1 MPa, splitting tensile strength between (5.7 – 13.9 MPa, flexural tensile strength (7.7 – 24.5 MPa, and static modulus of elasticity (32.7 – 47.1GPa. Based on the observations of this work, it was found that the cracks did not develop in the reduced scale of the reactive powder concrete (RPC walls restrained from movement at their bases for different L/H ratios (2, 5, and 10 and for two ratio of steel fiber (1% & 2% during 90 days period of drying conditions. Moreover, the shrinkage values increase toward the edges. Based on the results of this work, the increase in the maximum shrinkage values of walls with 1% steel fiber were (29%, 28%, 28% of the maximum shrinkage values of walls with 2% steel fiber of length/height ratios of (2, 5, and 10 respectively. The experimental observation in beam specimens showed that the free shrinkage, tensile strain capacity and elastic tensile strain capacity (at date of cracking of beams with 1% steel fiber were higher than the beams with 2% steel fiber by about (24%, (45% and (42% respectively

  13. Strength Behaviour Of Biomass Fiber-Reinforced Concrete Slab

    Directory of Open Access Journals (Sweden)

    Chai Teck Jung

    2012-05-01

    Full Text Available This paper investigates the compressive strength and flexural strength of biomass fibre-reinforced concrete slab. The main objective of this study is to examine the effect of biomass aggregate and fibre glass on the concrete slab strength. The biomass aggregate is used to replace the natural aggregates. A total of 36 slab samples (250 mm x 600 mm x 50mm thick and 36 numbers of 150 mm cube samples containing 0%, 30%, 60% and 100% biomass aggregate were prepared.  The E-class fibre and Supracoat SP800 were added to increase the strength and to achieve the required workability. All the samples were cured in water with room temperature of around 27oC and tested at the age of 7, 14 and 28 days respectively. The result showed that cube specimens containing 30% biomass aggregate concrete achieved minimum strength of 15 MPa at 28 days. The flexural strength for slab specimens containing 30% biomass aggregate, Supracoat SP 800 and fibre glass gained higher strength compared with control specimens. The 100% biomass aggregate slab achieved 88% of the control specimen strength. The workability was between 150 mm to 170mm slump. The density of the specimens was reduced 20% for cube and 28% for slab compared with control specimens. It can be concluded that the biomass aggregate has good potential as partial aggregate replacement in slab construction when combined with the use of glass fibre and superplasticizer. However, more research needs to be carried out to self-compacting biomass aggregate concrete for sustainable construction

  14. Connections in Precast Buildings using Ultra High-Strength Fibre Reinforced Concrete

    DEFF Research Database (Denmark)

    Hansen, Lars Pilegaard

    1995-01-01

    Ultra high-strength concrete adds new dimensions to the design of concrete structures. It is a brittle material but introducing fibres into the matrix changes the material into a highly ductile material. Furthermore, the fibre reinforcement increases the anchorage of traditional reinforcement bars...

  15. 78 FR 55755 - Steel Concrete Reinforcing Bar From Mexico and Turkey; Institution of Antidumping and...

    Science.gov (United States)

    2013-09-11

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Steel Concrete Reinforcing Bar From Mexico and Turkey; Institution of Antidumping and... from Mexico and Turkey of steel concrete reinforcing bar, primarily provided for in subheadings 7213.10...

  16. Corrosion and protection in reinforced concrete: pulse cathodic protection: an improved cost-effective alternative

    NARCIS (Netherlands)

    Koleva, D.A.

    2007-01-01

    Corrosion and protection in reinforced concrete. Pulse cathodic protection: an improved cost-effective alternative. The aim of the research project was to study the possibilities for establishing a new or improved electrochemical method for corrosion prevention/protection for reinforced concrete. Th

  17. 78 FR 68090 - Steel Concrete Reinforcing Bar from Mexico and Turkey

    Science.gov (United States)

    2013-11-13

    ... COMMISSION Steel Concrete Reinforcing Bar from Mexico and Turkey Determinations On the basis of the record \\1... injured by reason of imports from Mexico and Turkey of steel concrete reinforcing bar, provided for in... alleged to be sold in the United States at less than fair value (LTFV), and by imports of steel...

  18. Seismic response of reinforced concrete frames at different damage levels

    Science.gov (United States)

    Morales-González, Merangeli; Vidot-Vega, Aidcer L.

    2017-03-01

    Performance-based seismic engineering is focused on the definition of limit states to represent different levels of damage, which can be described by material strains, drifts, displacements or even changes in dissipating properties and stiffness of the structure. This study presents a research plan to evaluate the behavior of reinforced concrete (RC) moment resistant frames at different performance levels established by the ASCE 41-06 seismic rehabilitation code. Sixteen RC plane moment frames with different span-to-depth ratios and three 3D RC frames were analyzed to evaluate their seismic behavior at different damage levels established by the ASCE 41-06. For each span-to-depth ratio, four different beam longitudinal reinforcement steel ratios were used that varied from 0.85 to 2.5% for the 2D frames. Nonlinear time history analyses of the frames were performed using scaled ground motions. The impact of different span-to-depth and reinforcement ratios on the damage levels was evaluated. Material strains, rotations and seismic hysteretic energy changes at different damage levels were studied.

  19. EFFECT OF CORROSION ON BOND BEHAVIOR AND BENDING STRENGTH OF REINFORCED CONCRETE BEAMS

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    There is growing concern for corrosion damage in reinforced concrete structures with several decades' service. Pullout tests and beam tests were carried out to study the effect of reinforcement corrosion on the bond behavior and bending strength of reinforced concrete beams. The bond strength of plain bars and concrete initially increases with increasing corrosion, then declines. The turning point depends on the cracking of the concrete cover. The bond strength of deformed bars and concrete increases with corrosion up to a certain amount, but with progressive increase in corrosion, the bond strength decreases, and the cracking of the concrete cover seems to have no effect on the bond strength. On the basis of test data, the bond strength coefficient recommended here, which, together with the bond strength of uncorroded steel bars and concrete, can be used to easily calculate the bond strength of corroded steel bars and concrete. The bond strength coefficient proposed in this paper can be used to study the bond stress-slip relationship of corroded steel bars and concrete. The bending strength of corroded reinforced concrete beams declines with increasing reinforcement corrosion. Decreased bending strength of corroded RC beam is due to reduction in steel bar cross section, reduction of yield strength of steel bar, and reduction of bond capacity between steel bar and concrete.

  20. Efficiency of fiber reinforced concrete application in structures subjected to dynamic effects

    Directory of Open Access Journals (Sweden)

    Morozov Valeriy Ivanovich

    2014-03-01

    Full Text Available Fiber reinforced concretes possess high strength under dynamic loadings, which include impact loads, thanks to their high structural viscosity. This is the reason for using them in difficult operating conditions, where increasing the performance characteristics and the structure durability is of prime importance, and the issues of the cost become less significant. Applying methods of disperse reinforcement is most challenging in case of subtle high-porous materials on mineral binders, for example foamed concrete. At the same time, the experiments conducted in Russia and abroad show, that also in other cases the concrete strength resistance several times increases as a result of disperse reinforcement. This doesn't depend on average density of the concrete and type of fiber used. In the article the fibre reinforced concrete impact resistance is analysed. Recommendations are given in regard to fibre concrete application in manufacture of monolithic floor units for industrial buildings and precast piles.

  1. Modeling of Normal Perforation of Reinforced Concrete Slabs by a Rigid Projectile

    Institute of Scientific and Technical Information of China (English)

    CHEN Xiaowei; LI Xiaoli

    2006-01-01

    An analytical model on the normal perforation of reinforced concrete slabs is constructed.The effect of reinforcing bars is further hybridized in a general three-stage model consisting of initial cratering,tunnelling and shear plugging.Besides three dimensionless numbers,i.e.,the impact function /,the geometry function of projectile N and the dimensionless thickness of concrete target χ,which are employed to predict the ballistic performance of perforation of concrete slabs,the reinforcement ratio ρs of concrete and the tensile strength fs of reinforcing bars are considered as the other main factors influencing the perforation process.Simpler solutions of ballistic performances of normal perforation of reinforced concrete slabs are formulated.Theoretical predictions agree well with individual published experimental data.

  2. 78 FR 41079 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and Ukraine

    Science.gov (United States)

    2013-07-09

    ... COMMISSION Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and... Tariff Act of 1930 (19 U.S.C. 1675(c)), that revocation of the antidumping duty orders on steel concrete... views of the Commission are contained in USITC Publication 4409 (July 2013), entitled Steel Concrete...

  3. 78 FR 43858 - Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, the People's...

    Science.gov (United States)

    2013-07-22

    ...] Steel Concrete Reinforcing Bars From Belarus, Indonesia, Latvia, Moldova, Poland, the People's Republic... Department of Commerce (``Department'') that revocation of the antidumping duty orders \\1\\ on steel concrete... of the continuation of the antidumping duty orders. \\1\\ See Antidumping Duty Orders: Steel Concrete...

  4. Polymer concrete for precast repair of continuously reinforced concrete pavement on IH 30, near Mt. Pleasant

    Science.gov (United States)

    Meyer, A. M.; McCullough, B. F.; Fowler, D. W.

    1981-08-01

    Two punchout repairs made in a continuously reinforced concrete pavement (CRCP) using precast portland cement panels are described. The two repairs, one 1.44 sq. ft., the other 36 sq. ft., were completed and opened to traffic in one afternoon. This technique provides a rapid method of repair that produces a repair that is structurally as good or better than the surrounding pavement. With a trained crew, the repair time can be reduced and thus reducing lane closure time. Since lane closure time is a critical consideration in high volume highways, this method is cost effective in those areas.

  5. Multi-Physics and Multi-Scale Deterioration Modelling of Reinforced Concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Stang, Henrik; Lepech, M.;

    2016-01-01

    , methods and tools for modelling decades-long deterioration and maintenance are much less developed. In this paper, a multi-physics and multi-scale modelling approach for structural deterioration of reinforced concrete components due to reinforcement corrosion is presented. The multi-disciplinary modelling......Deterioration of reinforced concrete infrastructure such as bridges, tunnels, and buildings represents one of the major challenges currently facing developed countries. While engineering tools and methods for structural modelling and design of new reinforced concrete infrastructure are mature...

  6. Study of the shear behaviour of fibre reinforced concrete beams

    Directory of Open Access Journals (Sweden)

    Barragán, B.

    2008-12-01

    Full Text Available This study presents a series of tests for characterizing the structural behaviour of fibre reinforced concrete beams subjected to shear loading. The experimental program involves three types of fibres; two steel fibres and a polypropylene fibre. As a reference, plain concrete and conventionally reinforced concrete specimens have also been tested. The ultimate shear capacity of the beams is calculated and these values compared with those predicted by existing formulations. The study confirms that the toughness and shear crack resistance of the material is greatly enhanced by the fibres. However, the incorporation of 1% of fibres yielded lower shear strength than conventionally reinforced beams with the same amount of steel in the form of transversal stirrups. Existing design methods seem sufficiently robust to estimate the maximum shear load, even when using material properties (toughness, tensile strength extrapolated from code formulae.Este trabajo presenta una serie de ensayos para caracterizar el comportamiento estructural de vigas realizadas con hormigón reforzado con fibras sometidas a cortante. El programa de ensayos incluía tres tipos de fibras, dos de acero y una de polipropileno. Asimismo, se realizó una serie de ensayos con una viga confeccionada con hormigón armado convencional. La resistencia a cortante de las vigas es comparada con los valores que la formulación existente predice. El estudio confirma que la tenacidad y la resistencia a cortante son incrementadas tras la adición de fibras al hormigón. Sin embargo, la incorporación de un 1% en volumen de fibras conduce a valores de resistencia última a cortante inferiores a los obtenidos con vigas de hormigón convencional con la misma cantidad de acero dispuesta en forma de cercos de cortante. Los actuales métodos de cálculo parecen lo suficientemente precisos para evaluar la carga de cortante último, incluso cuando los parámetros mecánicos utilizados en las f

  7. Prediction of the Service Life of a Reinforced Concrete Column under Chloride Environment

    Directory of Open Access Journals (Sweden)

    Mohammad K. Alkam

    2015-01-01

    Full Text Available In the present investigation, service life of a reinforced concrete column exposed to chloride environment has been predicted. This study has been based on numerical simulation of chloride ion diffusion in a concrete column during its anticipated life span. The simulation process has included the concrete cover replacement whenever chloride ion concentration has reached the critical threshold value at the reinforcement surface. Repair scheduling of the concrete column under consideration has been discussed. Effects of the concrete cover thickness and the water cement ratio on the service life of the concrete column at hand have been presented. A new approach for arranging locations of reinforcement steel bars has been introduced. This approach is intended to prolong the service life of the concrete column under consideration against chloride induced corrosion.

  8. Utilisation of fibre reinforced polymer (FRP) composites in the confinement of concrete

    OpenAIRE

    Ciupala, Mihaela Anca; Pilakoutas, K.; Mortazavi, A.A.

    2007-01-01

    This paper presents an experimental investigation carried out on concrete cylinders\\ud confined with fibre reinforced polymers (FRP), subjected to monotonic and cyclic loading.\\ud Carbon fibres (CFRP) were used as confining material for the concrete specimens. The failure\\ud mode, reinforcement ratio based on jacket thickness and type of loading are examined. The study\\ud shows that external confinement of concrete can enhance its strength and ductility as well as result\\ud in large energy ab...

  9. Strength Design of Reinforced Concrete Hydraulic Structures; Report 3, T-Wall Design.

    Science.gov (United States)

    1982-01-01

    Concrete Reinforcing Steel Institute. 1978. CRSI Handbook, 3rd ed. Federation Internationale de la Precontrainte (FIP). 1974. "Recommen- dations for... concrete cover to the stirrups and main steel of a bridge floor beam that has been completely spalled off due to severe steel corrosion. 12. In this...Corrosion damage to a bridge floor beam C6 Tensile crack exposure tests by WES 13. Two series of reinforced concrete beams were made and exposed to

  10. Performance Assessment of Discontinuous Fibers in Fiber Reinforced Concrete: Current State-of-the-Art

    Science.gov (United States)

    2017-07-01

    strength between 190 to 240 MPa and is broadly characterized as a reactive powder concrete (RPC). RPCs have fine aggregates and powders but do not...ER D C/ G SL T R- 17 -1 9 Performance Assessment of Discontinuous Fibers in Fiber-Reinforced Concrete : Current State-of-the-Art G eo te...Discontinuous Fibers in Ultra-High Performance Fiber-Reinforced Concrete : Current State-of-the-Art Charles A. Burchfield Geotechnical and

  11. Punching shear of flat reinforced-concrete s labs under fire conditions

    OpenAIRE

    Smith, Holly Kate Mcleod

    2016-01-01

    This thesis examines punching shear response of reinforced-concrete flat slabs under fire conditions. The shear behaviour of concrete in fire is relatively poorly understood compared to its flexural response. Failures such as the Gretzenbach car park failure in Switzerland (2004) have prompted concerns over the punching shear capacity of flat slabs in fire. The shear behaviour of reinforced-concrete in fire depends on degradation of the individual material properties with te...

  12. Numerical Simulation of Monitoring Corrosion in Reinforced Concrete Based on Ultrasonic Guided Waves

    OpenAIRE

    Zheng, Zhupeng; Lei, Ying; Xue, Xin

    2014-01-01

    Numerical simulation based on finite element method is conducted to predict the location of pitting corrosion in reinforced concrete. Simulation results show that it is feasible to predict corrosion monitoring based on ultrasonic guided wave in reinforced concrete, and wavelet analysis can be used for the extremely weak signal of guided waves due to energy leaking into concrete. The characteristic of time-frequency localization of wavelet transform is adopted in the corrosion monitoring of re...

  13. Topology optimization of reinforced concrete beams by a spread-over reinforcement model with fixed grid mesh

    OpenAIRE

    Benjapon Wethyavivorn; Siradech Surit

    2011-01-01

    For this investigation, topology optimization was used as a tool to determine the optimal reinforcement for reinforcedconcrete beam. The topology optimization process was based on a unit finite element cell with layers of concrete and steel.The thickness of the reinforced steel layer of this unit cell was then adjusted when the concrete layer could not carry thetensile or compressive stress. At the same time, unit cells which carried very low stress were eliminated. The process wasperformed i...

  14. Hybrid Effect Evaluation of Steel Fiber and Carbon Fiber on the Performance of the Fiber Reinforced Concrete

    OpenAIRE

    Weimin Song; Jian Yin

    2016-01-01

    Fiber reinforcement is an important method to enhance the performance of concrete. In this study, the compressive test and impact test were conducted, and then the hybrid effect between steel fiber (SF) and carbon fiber (CF) was evaluated by employing the hybrid effect index. Compressive toughness and impact toughness of steel fiber reinforced concrete (SFRC), carbon fiber reinforced concrete (CFRC) and hybrid fiber reinforced concrete (HFRC) were explored at steel fiber volume fraction 0.5%,...

  15. Evaluating cover depth of steel fiber reinforced concrete using impact-echo testing

    Science.gov (United States)

    Lin, Yu-Feng

    2014-04-01

    The purpose of this research is to estimate of the cover depth of steel fiber reinforced concrete using the impact-echo testing. In order to evaluate the security of the construction, usually need to estimate the cover depth of the reinforced concrete. At present, the examination technique of the cover depth of the reinforced concrete without the steel fiber is mainly applied in the magnetic and electrical methods, its rapid detection and good results. But the research of the reactive powder concrete be gradually progress, with the steel fiber concrete structure will be increased, if should still operate the examination with the magnetic and electrical methods, theoretically the steel fiber will have the interference to its electromagnetism field. Therefore, this research designs four kinds of reinforced concrete plate that include different steel fiber contents, to evaluate test results of estimate of the cover depth of the reinforcing bar. The results showed that: estimate of the cover depth of steel fiber reinforced concrete reinforcing bar using the impact-echo testing, the variety of the steel fiber content does not have much influence, the test measurement error within ± 10%, and the most important source of uncertainty is the velocity of concrete.

  16. Confinement of Reinforced-Concrete Columns with Non-Code Compliant Confining Reinforcement plus Supplemental Pen-Binder

    Directory of Open Access Journals (Sweden)

    Anang Kristianto

    2012-11-01

    Full Text Available One of the important requirements for earthquake resistant building related to confinement is the use of seismic hooks in the hoop or confining reinforcement of reinforced-concrete column elements. However, installation of a confining reinforcement with a 135-degree hook is not easy. Therefore, in practice, many construction workers apply a confining reinforcement with a 90-degreehook (non-code compliant. Based on research and records of recent earthquakes in Indonesia, the use of a non-code compliant confining reinforcement for concrete columns produces structures with poor seismic performance. This paper presents a study that introduces an additional element that is expected to improve the effectiveness of concrete columns confined with a non-code compliant confining reinforcement. The additional element, named a pen-binder, is used to keep the non-code compliant confining reinforcement in place. The effectiveness of this element under pure axial concentric loading was investigatedcomprehensively.The specimens tested in this study were 18 concrete columns,with a cross-section of 170 mm x 170 mm and a height of 480 mm. The main test variables were the material type of the pen-binder, the angle of the hook, and the confining reinforcement configuration.The test results indicate that adding pen-binders can effectively improve the strength and ductility of the column specimens confined with a non-code compliant confining reinforcement

  17. Study of Reinforced Concrete Beam-Column Joint

    Directory of Open Access Journals (Sweden)

    Prakash Panjwania

    2015-06-01

    Full Text Available The beam column joint is the crucial zone in a reinforced concrete moment resisting frame. It is subjected to large forces during severe ground shaking and its behaviour has a significant influence on the response of the structure. The assumption of rigid joint fails to consider the effects of high shear forces developed within the joint. The shear failure is always brittle in nature which is not an acceptable structural performance especially in seismic conditions. This paper presents a review of the postulated theories associated with the behaviour of joints. Understanding the joint behaviour is essential in exercising proper judgments in the design of joints. The paper discusses about the seismic actions on various types of joints and highlights the critical parameters that affect joint performance with special reference to bond and shear transfer

  18. Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection

    Directory of Open Access Journals (Sweden)

    Dong Luo

    2016-12-01

    Full Text Available In this study, tapered polymer fiber sensors (TPFSs have been employed to detect the vibration of a reinforced concrete beam (RC beam. The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well with Kistler accelerometers. The experimental results found that both the accelerometer and TPFS detected the natural frequency function of a vibrated RC beam well. The mode shapes of the RC beam were also found by using the TPFSs. The proposed vibration detection method provides a cost-comparable solution for a structural health monitoring (SHM system in civil engineering.

  19. Effect of wind in the design of reinforced concrete buildings

    Directory of Open Access Journals (Sweden)

    L.S. Tapajós

    Full Text Available ABSTRACT This paper presents the results from a parametric study carried in order to quantify how far errors in the design stage related to the consideration of the wind action may put at risk the response and safety of reinforced concrete buildings. Using an architectural model as reference and varying the number of floors of the building, the structural safety was evaluated as a function of the wind action intensity. Results showed that even for low-rise buildings, with 10 floors, ignoring the wind action can significantly jeopardize their behaviour and safety. Yet, for slenderer buildings, up to 30 floors, it can lead to catastrophic results, as the ruin of the structure by progressive collapse.

  20. Behaviour of a Blast Loaded Laced Reinforced Concrete Structure

    Directory of Open Access Journals (Sweden)

    N. Anandavalli

    2012-09-01

    Full Text Available Normal 0 MicrosoftInternetExplorer4 According to existing provisions, large separation distance has to be maintained between two conventional explosive storage structures to prevent sympathetic detonation. In this paper, reduction of the separation distance with the use of earth covered laced reinforced concrete (LRC storage structure is demonstrated, which will result in saving of land cost. Details of blast resistant design of 75T (NEC storage structure based on unit risk principle are presented. Performance of the storage structure is evaluated in an actual blast trial. Strain and deflection profiles are obtained from the trial. Based on these, the storage structure is found to be re-usable after the blast trial.Defence Science Journal, 2012, 62(5, pp.284-289, DOI:http://dx.doi.org/10.14429/dsj.62.820

  1. Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection.

    Science.gov (United States)

    Luo, Dong; Ibrahim, Zainah; Ma, Jianxun; Ismail, Zubaidah; Iseley, David Thomas

    2016-12-16

    In this study, tapered polymer fiber sensors (TPFSs) have been employed to detect the vibration of a reinforced concrete beam (RC beam). The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well with Kistler accelerometers. The experimental results found that both the accelerometer and TPFS detected the natural frequency function of a vibrated RC beam well. The mode shapes of the RC beam were also found by using the TPFSs. The proposed vibration detection method provides a cost-comparable solution for a structural health monitoring (SHM) system in civil engineering.

  2. Analysis of reinforced concrete beams by the equivalent section method

    CERN Document Server

    Schulz, Mauro

    2014-01-01

    This research investigates the analysis of reinforced concrete beams subjected to combined axial load, bending moment and shear force. Cross-sections of general shape are divided, along the height, into plane elements. The biaxial behavior is represented according to the smeared rotating crack approach. Using traditionally accepted hypotheses for beams, the shear flow is determined by applying the Jouravski formula to an "equivalent section", which takes into account the nonlinear material behavior. The "Equivalent Section Method", originally proposed by Diaz (1980) and Diaz and Schulz (1981), is improved and simplified. The formulation is implemented applying the bidimensional constitutive model A, proposed by Vecchio and Collins (1993). The tension-stiffening effect is considered as adopted by Polak and Vecchio (1993). Shear slip at crack surfaces, Poisson's ratio and other secondary effects are not considered. Validation is undertaken by comparison with experimental results obtained by other researchers. T...

  3. Environmental Impact Optimization of Reinforced Concrete Slab Frame Bridges

    DEFF Research Database (Denmark)

    Yavari, Majid Solat; Du, Guangli; Pacoste, Costin

    2017-01-01

    The main objective of this research is to integrate environmental impact optimization in the structural design of reinforced concrete slab frame bridges in order to determine the most environmental-friendly design. The case study bridge used in this work was also investigated in a previous paper...... focusing on the optimization of the investment cost, while the present study focuses on environmental impact optimization and comparing the results of both of these studies. Optimization technique based on the pattern search method was implemented. Moreover, a comprehensive Life Cycle Assessment (LCA......) methodology of ReCiPe and two monetary weighting systems were used to convert environmental impacts into monetary costs. The analysis showed that both monetary weighting systems led to the same results. Furthermore, optimization based on environmental impact generated models with thinner construction elements...

  4. Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank

    Directory of Open Access Journals (Sweden)

    Bharti Tekwani

    2016-05-01

    Full Text Available This paper compares the results of Seismic Analysis of Reinforced Concrete Shaft Support Water Storage Tank carried out in accordance with IS: 1893- 1984 and IS: 1893-2002 (Part-2 draft code. The analysis is carried out for shaft supported water tank of 500,750 and 1000 Cu.m capacity, located in four seismic zones (Zone-II, Zone -III, Zone-IV, Zone-V and on three different soil types (Hard rock, Medium soil, Soft soil. Further, 1000 kl tank for conditions - tank full, tank empty are also considered in this study. The analysis was performed using MAT LAB. The parameters of comparison include base shears, base moments and time history analysis. The above models are analyzed for different time history data such as El Centro, Kobe, Ji-Ji, Erzincan. The comparison is made between the structural responses of one mass and two mass models of above capacity.

  5. 75 FR 47260 - Certain Steel Concrete Reinforcing Bars from Turkey: Notice of Amended Final Results Pursuant to...

    Science.gov (United States)

    2010-08-05

    ... International Trade Administration (A-489-807) Certain Steel Concrete Reinforcing Bars from Turkey: Notice of...) in the 2005-2006 administrative review of certain steel concrete reinforcing bars (rebar) from Turkey..., through March 31, 2006. See Certain Steel Concrete Reinforcing Bars From Turkey; Final Results of...

  6. 75 FR 22552 - Certain Steel Concrete Reinforcing Bars from Turkey; Notice of Amended Final Results Pursuant to...

    Science.gov (United States)

    2010-04-29

    ... International Trade Administration Certain Steel Concrete Reinforcing Bars from Turkey; Notice of Amended Final... Department) in the 2003-2004 administrative review of certain steel concrete of reinforcing bars (rebar) from...) of April 1, 2003, through March 31, 2004. See Certain Steel Concrete Reinforcing Bars From Turkey...

  7. 75 FR 7562 - Certain Steel Concrete Reinforcing Bars From Turkey: Notice of Court Decision Not in Harmony With...

    Science.gov (United States)

    2010-02-22

    ... International Trade Administration Certain Steel Concrete Reinforcing Bars From Turkey: Notice of Court Decision... certain steel concrete reinforcing bars (rebar) from Turkey covering the period of review (POR) of April 1, 2003, through March 31, 2004. See Certain Steel Concrete Reinforcing Bars From Turkey; Final...

  8. Performance based analysis of hidden beams in reinforced concrete structures

    Directory of Open Access Journals (Sweden)

    Helou Samir H.

    2014-01-01

    Full Text Available Local and perhaps regional vernacular reinforced concrete building construction leans heavily against designing slabs with imbedded hidden beams for flooring systems in most structures including major edifices. The practice is distinctive in both framed and in shear wall structures. Hidden beams are favoured structural elements due to their many inherent features that characterize them; they save on floor height clearance; they also save on formwork, labour and material cost. Moreover, hidden beams form an acceptable aesthetic appearance that does not hinder efficient interior space partitioning. Such beams have the added advantage of clearing the way for horizontal electromechanical ductwork. However, seismic considerations, in all likelihood, are seldom seriously addressed. The mentioned structural system of shallow beams is adopted in ribbed slabs, waffle slabs and at times with solid slabs. Ribbed slabs and waffle slabs are more prone to hidden beam inclusion due to the added effective height of the concrete section. Due to the presence of a relatively high reinforcement ratio at the joints the sections at such location tend to become less ductile with unreliable contribution to spandrel force resistance. In the following study the structural influence of hidden beams within slabs is investigated. With the primary focus on a performance based analysis of such elements within a structure. This is investigated with due attention to shear wall contribution to the overall behaviour of such structures. Numerical results point in the direction that the function of hidden beams is not as adequate as desired. Therefore it is strongly believed that they are generally superfluous and maybe eliminated altogether. Conversely, shallow beams seem to render the overall seismic capacity of the structure unreliable. Since such an argument is rarely manifested within the linear analysis domain; a pushover analysis exercise is thus mandatory for behaviour

  9. Seismic analysis of a reinforced concrete containment vessel model

    Energy Technology Data Exchange (ETDEWEB)

    RANDY,JAMES J.; CHERRY,JEFFERY L.; RASHID,YUSEF R.; CHOKSHI,NILESH

    2000-02-03

    Pre-and post-test analytical predictions of the dynamic behavior of a 1:10 scale model Reinforced Concrete Containment Vessel are presented. This model, designed and constructed by the Nuclear Power Engineering Corp., was subjected to seismic simulation tests using the high-performance shaking table at the Tadotsu Engineering Laboratory in Japan. A group of tests representing design-level and beyond-design-level ground motions were first conducted to verify design safety margins. These were followed by a series of tests in which progressively larger base motions were applied until structural failure was induced. The analysis was performed by ANATECH Corp. and Sandia National Laboratories for the US Nuclear Regulatory Commission, employing state-of-the-art finite-element software specifically developed for concrete structures. Three-dimensional time-history analyses were performed, first as pre-test blind predictions to evaluate the general capabilities of the analytical methods, and second as post-test validation of the methods and interpretation of the test result. The input data consisted of acceleration time histories for the horizontal, vertical and rotational (rocking) components, as measured by accelerometers mounted on the structure's basemat. The response data consisted of acceleration and displacement records for various points on the structure, as well as time-history records of strain gages mounted on the reinforcement. This paper reports on work in progress and presents pre-test predictions and post-test comparisons to measured data for tests simulating maximum design basis and extreme design basis earthquakes. The pre-test analyses predict the failure earthquake of the test structure to have an energy level in the range of four to five times the energy level of the safe shutdown earthquake. The post-test calculations completed so far show good agreement with measured data.

  10. Uncertainty modelling of critical column buckling for reinforced concrete buildings

    Indian Academy of Sciences (India)

    Kasim A Korkmaz; Fuat Demir; Hamide Tekeli

    2011-04-01

    Buckling is a critical issue for structural stability in structural design. In most of the buckling analyses, applied loads, structural and material properties are considered certain. However, in reality, these parameters are uncertain. Therefore, a prognostic solution is necessary and uncertainties have to be considered. Fuzzy logic algorithms can be a solution to generate more dependable results. This study investigates the material uncertainties on column design and proposes an uncertainty model for critical column buckling reinforced concrete buildings. Fuzzy logic algorithm was employed in the study. Lower and upper bounds of elastic modulus representing material properties were defined to take uncertainties into account. The results show that uncertainties play an important role in stability analyses and should be considered in the design. The proposed approach is applicable to both future numerical and experimental researches. According to the study results, it is seen that, calculated buckling load values are stayed in lower and upper bounds while the load values are different for same concrete strength values by using different code formula.

  11. Humectant use in the cathodic protection of reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, Gordon R.; Covino, Bernard S., Jr.; Russell, James H.; Bullard, Sophie J.; Cramer, Stephen D.; Collins, W.K.; Bennett, J.E. (JE Bennett Consulting); Laylor, H.M. (ODOT)

    2000-11-01

    Use of humectants to improve the thermal-sprayed zinc anode performance during the cathodic protection (CP) of reinforced concrete was examined. A humectant is a hygroscopic material. It is applied onto the surface of the zinc anode to keep the concrete-anode interface moist and a good conductor. The thermodynamics of humectants are discussed. Laboratory results are presented on the effects of using lithium bromide (LiBr) and lithium nitrate (LiNO{sub 3}) as humectants in galvanic cathodic protection (GCP) and impressed current cathodic protection (ICCP) systems, in high and low relative humidities, and on new and previously electrochemically aged CP systems. LiNO{sub 3} and LiBr promoted more effective CP performance. Both improved the performance of aged slabs, suggesting that application of humectants onto existing CP systems would be of benefit. Microscopy showed that humectant-treated slabs develop the same cement-reaction zone, zinc anode structures as untreated slabs. Microscopy of LiBr-treated slabs revealed that the highest concentration of bromide was in the reaction zone. In GCP tests, LiBr was more effective than LiNO{sub 3}. In accelerated ICCP tests, LiNO{sub 3} was more effective than LiBr. It was surmised that bromide could be oxidized in the high-voltage accelerated ICCP tests. At the lower impressed currents of most installed ICCP systems, LiBr may perform as well as or better than LiNO{sub 3}.

  12. Humectant use in the cathodic protection of reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, G.R.; Covino, B.S. Jr.; Russell, J.H.; Bullard, S.J.; Cramer, S.D.; Collins, W.K.; Bennett, J.E. (not a DOE author); H.M. Laylor (not a DOE author)

    2000-03-01

    The use of humectants to improve the thermal-sprayed zinc anode performance during the cathodic protection (CP) of reinforced concrete is examined. A humectant is a hygroscopic material. It is applied onto the surface of the zinc anode to keep the concrete-anode interface moist and a good conductor. The thermodynamics of humectants are discussed. Laboratory results are presented on the effects of using LiBr and LiNO{sub 3} as humectants in galvanic (GCP) and impressed current (ICCP) systems, in high and low relative humidities, and on new and previously electrochemically aged CP systems. LiNO{sub 3} and LiBr promoted more effective CP performance. Both improved the performance of aged slabs, suggesting that application of humectants onto existing CP systems would be of benefit. Microscopy showed that humectant-treated slabs develop the same cement-reaction zone-zinc anode structures as untreated slabs. Microscopy of LiBr-treated slabs revealed that the highest concentration of bromide was in the reaction zone. In GCP tests, LiBr was more effective than LiNO{sub 3}. In accelerated ICCP tests, LiNO{sub 3} was more effective than LiBr. It was surmised that bromide could be oxidized in the high-voltage accelerated ICCP tests. At the lower impressed currents of most installed ICCP systems, LiBr may perform as well as or better than LiNO{sub 3}.

  13. Crack Identification in Reinforced Concrete Beams Using Ansys Software

    Directory of Open Access Journals (Sweden)

    T. Subramani

    2014-06-01

    Full Text Available Analytical determination of displacements and stresses in reinforced concrete material was difficult task and engineers had to rely on empirical formulas because concrete consists of heterogeneous material and creep and shrinkage influenced deformations in it. Due to these complexities engineers in past had been facing difficulties in coping such problems, but with the advancement of digital computerization and modern numerical methods for analysis such as finite element method, these problems can be addressed in a very efficient way. There were two ways to carry out modelling in ANSYS software, one was smeared approach and the other one was discrete. In the past, Smeared approach was used to identify the cracks in RC beam using ANSYS but in this work it was extended using discrete approach of modelling and shear cracks were identified in RC beam and load deflection curve was simulated which showed good agreement with the experimental results. Beams, made of brittle materials like concrete or cement, show increasing crack development during their service life due to mechanical and environmental loadings. This local damage can be translated into a reduction of the local bending stiffness. Stiffness modifications, while assuming constant mass distribution, can be observed by monitoring the vibration behaviour of the beam. In this paper the modal parameters of an undamaged beam are monitored and compared with the vibration behaviour of the beam subjected to controlled damaging. Selected stiffness parameters in the finite element model are adjusted in such a way that the computed modal quantities match the measured quantities. FEMtools has been used to establish a damage distribution in beams associated with increasing stress patterns. State of the art scanning laser modal equipment has been used for this purpose. It has been found that modal updating is indeed a possible tool to reconstruct the damage patterns.

  14. Numerical Modelling Of The Strengthening Process Of Steel-Concrete Composite Beams

    Directory of Open Access Journals (Sweden)

    Szewczyk Piotr

    2015-12-01

    Full Text Available This paper presents the numerical modelling of strengthening a steel-concrete composite beam. The main assumption is that the strengthening is not the effect of the state of a failure of a structure, but it resulted from the need to increase the load-bearing capacity and stiffness of the structure (for example: due to a change in the use of the object. The expected solution is strengthening without the necessity to completely unload the structures (to reduce the scope of works, the cost of modernization and to shorten the time. The problem is presented on the example of a composite beam which was strengthened through welding a steel plate to the lower flange of the steel beam. The paper describes how energy parameters are used to evaluate the efficiency of structures’ strengthening and proposes an appropriate solution.

  15. Intermediate Crack Induced Debonding in Concrete Beams Strengthened with CFRP Plates - An Experimental Study

    DEFF Research Database (Denmark)

    Rusinowski, Piotr Michal; Täljsten, Björn

    2009-01-01

    , ductility and even durability. Design of structural strengthening applications using externally bonded FRP composites is usually based on conventional design approaches with improvement to account for the presence and characteristics of the FRP material. Non-conventional design issues that are specific...... of the strengthening method. End-peeling has governed a large interest and several debonding models have been presented. However, interfacial peeling at flexural cracks has not attained the same focus – even though this debonding failure is most likely more common. This paper presents laboratory tests of concrete...... beams strengthened in flexure with CFRP epoxy bonded plates. Wrapping with CFRP sheets was applied in order to try to localize the failure initiation. Concrete cracking as well as debonding initiation and propagation was possible to observe with help of advanced optical measuring system and high speed...

  16. Optimization of the Infrastructure of Reinforced Concrete Reservoirs by a Particle Swarm Algorithm

    Directory of Open Access Journals (Sweden)

    Kia Saeed

    2015-03-01

    Full Text Available Optimization techniques may be effective in finding the best modeling and shapes for reinforced concrete reservoirs (RCR to improve their durability and mechanical behavior, particularly for avoiding or reducing the bending moments in these structures. RCRs are one of the major structures applied for reserving fluids to be used in drinking water networks. Usually, these structures have fixed shapes which are designed and calculated based on input discharges, the conditions of the structure's topology, and geotechnical locations with various combinations of static and dynamic loads. In this research, the elements of reservoir walls are first typed according to the performance analyzed; then the range of the membrane based on the thickness and the minimum and maximum cross sections of the bar used are determined in each element. This is done by considering the variable constraints, which are estimated by the maximum stress capacity. In the next phase, based on the reservoir analysis and using the algorithm of the PARIS connector, the related information is combined with the code for the PSO algorithm, i.e., an algorithm for a swarming search, to determine the optimum thickness of the cross sections for the reservoir membrane’s elements and the optimum cross section of the bar used. Based on very complex mathematical linear models for the correct embedding and angles related to achain of peripheral strengthening membranes, which optimize the vibration of the structure, a mutual relation is selected between the modeling software and the code for a particle swarm optimization algorithm. Finally, the comparative weight of the concrete reservoir optimized by the peripheral strengthening membrane is analyzed using common methods. This analysis shows a 19% decrease in the bar’s weight, a 20% decrease in the concrete’s weight, and a minimum 13% saving in construction costs according to the items of a checklist for a concrete reservoir at 10,000 m3.

  17. Shear-deforming textile reinforced concrete for the construction of double-curved structures

    NARCIS (Netherlands)

    Woodington, W.; Bergsma, O.K.; Schipper, H.R.

    2015-01-01

    A composite textile reinforced concrete (TRC) material is developed to overcome the difficulties of constructing double-curved freeform structures. This is possible by shear-deformation of the woven reinforcement. It affects the direction of reinforcement and thickness, resulting in variable orthotr

  18. Behavior and Performance of GFRP Reinforced Concrete Columns with Various Types of Stirrups

    Directory of Open Access Journals (Sweden)

    Woraphot Prachasaree

    2015-01-01

    Full Text Available Fiber reinforced polymer (FRP composites are gaining acceptance in concrete structural applications due to their high ratio of strength/stiffness to self-weight and corrosion resistance. This study focused on the structural behavior and the performance of concrete columns internally reinforced with glass fiber reinforced plastic (GFRP rebars. Twelve series of concrete columns with varied longitudinal reinforcement, cross section, concrete cover, and type of lateral reinforcement were tested under compression loading. The results show that the amount of GFRP longitudinal and lateral reinforcement slightly affects the column strength. The lateral reinforcement affects the confining pressure and inelastic deformation, and its contribution to the confined compressive strength increases with the GFRP reinforcement ratio. In addition, the confining pressure increases both concrete strength and deformability in the inelastic range. The confinement effectiveness coefficient varied from 3.0 to 7.0 with longitudinal reinforcement. The average deformability factors were 4.2 and 2.8 with spirals and ties, respectively. Lateral reinforcement had a more pronounced effect on deformability than on column strength.

  19. Analytical Study on the Beyond Design Seismic Capacity of Reinforced Concrete Shear Walls

    Energy Technology Data Exchange (ETDEWEB)

    Nugroho, Tino Sawaldi Adi [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Chi, Ho-Seok [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    The OECD-NEA has organized an international benchmarking program to better understand this critical issue. The benchmark program provides test specimen geometry, test setup, material properties, loading conditions, recorded measures, and observations of the test specimens. The main objective of this research is to assess the beyond design seismic capacity of the reinforced concrete shear walls tested at the European Laboratory for Structural Assessment between 1997 and 1998 through participation in the OECD-NEA benchmark program. In this study, assessing the beyond design seismic capacity of reinforced concrete shear walls is performed analytically by comparing numerical results with experimental results. The seismic shear capacity of the reinforced concrete shear wall was predicted reasonably well using ABAQUS program. However, the proper calibration of the concrete material model was necessary for better prediction of the behavior of the reinforced concrete shear walls since the response was influenced significantly by the material constitutive model.

  20. Assessment of Methods for Development of Confinement Model of Low Strength Reinforced Concrete Columns: A Review

    Directory of Open Access Journals (Sweden)

    Asif Ali

    2016-10-01

    Full Text Available Reinforced Concrete is composed of concrete and steel, where compressive strength of concrete and tensile strength of steel are utilized to achieve the required member strength. The high tensile property of steel is thus used to confine and increase compressive strength and ductility of RC columns. Confined concrete is defined as concrete that is restrained laterally by any internal or external means i.e. reinforcement consisting of steel stirrups or spirals, Fiber Reinforced Polymer (FRP, Circular Concrete Filled Steel Tube, RC shell jacketing etc. An appropriate amount of confinement increases the strength, ductility and energy dissipation capacity of RC members. This paper focuses on finding out strength and ductility enhancement of low strength RC columns by reinforcement using existing confinement models. Confinement models are stress-strain curves developed for concrete compression member under uniaxial or dynamic loading, confined with transverse reinforcement. Different models along with their experimental validations are discussed in this paper to get state of the art knowledge of confinement studies possible for low strength concrete. The models recommended from this study are used to evaluate existing structures made with low strength concrete

  1. Containment performance evaluation of prestressed concrete containment vessels with fiber reinforcement

    Energy Technology Data Exchange (ETDEWEB)

    Choun, Young Sun; Park, Hyung Kui [Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    Fibers in concrete resist the growth of cracks and enhance the postcracking behavior of structures. The addition of fibers into a conventional reinforced concrete can improve the structural and functional performance of safety-related concrete structures in nuclear power plants. The influence of fibers on the ultimate internal pressure capacity of a prestressed concrete containment vessel (PCCV) was investigated through a comparison of the ultimate pressure capacities between conventional and fiber-reinforced PCCVs. Steel and polyamide fibers were used. The tension behaviors of conventional concrete and fiber-reinforced concrete specimens were investigated through uniaxial tension tests and their tension-stiffening models were obtained. For a PCCV reinforced with 1% volume hooked-end steel fiber, the ultimate pressure capacity increased by approximately 12% in comparison with that for a conventional PCCV. For a PCCV reinforced with 1.5% volume polyamide fiber, an increase of approximately 3% was estimated for the ultimate pressure capacity. The ultimate pressure capacity can be greatly improved by introducing steel and polyamide fibers in a conventional reinforced concrete. Steel fibers are more effective at enhancing the containment performance of a PCCV than polyamide fibers. The fiber reinforcement was shown to be more effective at a high pressure loading and a low prestress level.

  2. Mechanical interaction between concrete and structural reinforcement in the tension stiffening process

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2011-01-01

    investigated using an image-based deformation measurement and analysis system. This allowed for detailed view of surface deformations and the implications on the resulting response of the member in tension. In this study, conventional concrete and a ductile, strain hardening cement composite, known......The interaction between structural reinforcement and the surrounding concrete matrix in tension is a governing mechanism in the structural response of reinforced concrete members. The tension stiffening process, defined as the concrete ´s contribution to tensile response of the composite, has been...... as Engineered Cementitious Composite (ECC), have been combined with steel and glass fiber reinforced polymer (GFRP) reinforcement to contrast the effects of brittle and ductile cement matrices as well as elastic/plastic and elastic reinforcement on the tension stiffening process. Particular focus...

  3. Analysis on plastic properties of reactive powder concrete continuous beams reinforced with GFRP bars

    Institute of Scientific and Technical Information of China (English)

    LU Shan-shan; ZHENG Wen-zhong

    2010-01-01

    To study the plastic properties of reactive powder concrete continuous beams reinforced with GFRP bars,the calculation programs for moment redistribution coefficients are prepared by using nonlinear analysis methods such as moment-curvature,conjugate beam method and so on.By comparing the test results of existed FRP bars reinforced concrete continuous beams with simulation results,the accuracy of the calculation program is verified.Then 18 simulated GFRP bars reinforced reactive powder concrete continuous beams are selected whose change parameters are reinforcement ratio of mid-span and middle support.Through the nonlinear analysis of simulated beams,moment redistribution coefficients under mid-span concentrated loads,one-third point loads and uniformly distributed loads are obtained respectively.Thus the formula of moment redistribution coefficients is obtained by fitting moment redistribution coefficients and factors.The results show that the reactive powder concrete continuous beams reinforced with GFRP bars have good plastic properties.

  4. Evaluation of seismic shear capacity of prestressed concrete containment vessels with fiber reinforcement

    Energy Technology Data Exchange (ETDEWEB)

    Choun, Young Sun; Park, Jun Hee [Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Fibers have been used in cement mixture to improve its toughness, ductility, and tensile strength, and to enhance the cracking and deformation characteristics of concrete structural members. The addition of fibers into conventional reinforced concrete can enhance the structural and functional performances of safety-related concrete structures in nuclear power plants. The effects of steel and polyamide fibers on the shear resisting capacity of a prestressed concrete containment vessel (PCCV) were investigated in this study. For a comparative evaluation between the shear performances of structural walls constructed with conventional concrete, steel fiber reinforced concrete, and polyamide fiber reinforced concrete, cyclic tests for wall specimens were conducted and hysteretic models were derived. The shear resisting capacity of a PCCV constructed with fiber reinforced concrete can be improved considerably. When steel fiber reinforced concrete contains hooked steel fibers in a volume fraction of 1.0%, the maximum lateral displacement of a PCCV can be improved by > 50%, in comparison with that of a conventional PCCV. When polyamide fiber reinforced concrete contains polyamide fibers in a volume fraction of 1.5%, the maximum lateral displacement of a PCCV can be enhanced by ∼40%. In particular, the energy dissipation capacity in a fiber reinforced PCCV can be enhanced by > 200%. The addition of fibers into conventional concrete increases the ductility and energy dissipation of wall structures significantly. Fibers can be effectively used to improve the structural performance of a PCCV subjected to strong ground motions. Steel fibers are more effective in enhancing the shear performance of a PCCV than polyamide fibers.

  5. Application of Cu-Al-Mn superelastic alloy bars as reinforcement elements in concrete beams

    Science.gov (United States)

    Shrestha, Kshitij C.; Araki, Yoshikazu; Nagae, Takuya; Yano, Hayato; Koetaka, Yuji; Omori, Toshihiro; Sutou, Yuji; Kainuma, Ryosuke; Ishida, Kiyohito

    2012-04-01

    Experimental works are done to assess the seismic behavior of concrete beams reinforced with superelastic alloy (SEA) bars. Applicability of newly developed Cu-Al-Mn SEA bars, characterized by large recovery strain, low material cost, and high machinability, have been proposed as partial replacements for conventional steel bars in order to reduce residual deformations in structures during and after intense earthquakes. Four-point reverse-cyclic bending tests were done on 1/3 scale concrete beams comprising three different types of specimens - conventional steel reinforced concrete (ST-RC), SEA reinforced concrete (SEA-RC), and SEA reinforced concrete with pre-tensioning (SEA-PC). The results showed that SEA reinforced concrete beams demonstrated significant enhancement in crack recovery capacity in comparison to steel reinforced beam. Average recovery of cracks for each of the specimens was 21% for ST-RC, 84% for SEA-RC, and 86% for SEA-PC. In addition, SEA-RC and SEA-PC beams demonstrated strong capability of recentering with comparable normalized strength and ductility relative to conventional ST-RC beam specimen. ST-RC beam, on the other hand, showed large residual cracks due to progressive reduction in its re-centering capability with each cycle. Both the SEA-RC and SEA-PC specimens demonstrated superiority of Cu-Al-Mn SEA bars to conventional steel reinforcing bars as reinforcement elements.

  6. Study on improvement of durability for reinforced concrete by surface-painting migrating corrosion inhibitor and engineering application

    Science.gov (United States)

    Song, Ning; WANG, Zixiao; LIU, Zhiyong; Zhou, Jiyuan; Zheng, Duo

    2017-01-01

    The corrosion currents of steel bar in concrete with three W/B and four chloride contents after surface-painting two migrating corrosion inhibitors (PCI-2015 and MCI-A) 14d to 150d in atmospheric condition were measured. The results showed that the corrosion current density (I corr) of steel bar reduced to 0.1 μA.cm-2 from the initial highest 3.833 μA.cm-2 (W/B=0.65, NaCl-1%) after surface-painting PCI-2015 14 d, and the I corr was still lower than 0.1 μA.cm-2 until 150d. The compressive strength and chloride migration coefficient of concrete specimens were tested. The possible reasons of the mechanisms of durability improvement for reinforced concrete by applying PCI-2015 inhibitor were PCI-2015 may be reacted with calcium hydroxide in cement concrete and lots of inhibitor particles may be adsorbed on the active sites first and then a stable protective layer may be formed. The I corr of steel bars in a hydraulic aqueduct concrete structure after painting PCI-2015, MCI-A (the United States) and MCI-B (Europe) during 6 months was monitored by Gecor 8 tester. The results showed that the average values of I corr of steel bars after painting the PCI-2015 150d fulfilled the specification requirements in “Design code for concrete structure strengthening (E.3) ”(GB 50367-2013).

  7. Reinforcement layout design for concrete structures based on continuum damage and truss topology optimization

    DEFF Research Database (Denmark)

    Amir, Oded; Sigmund, Ole

    2013-01-01

    This article presents a new procedure for the layout design of reinforcement in concrete structures. Concrete is represented by a gradient-enhanced continuum damage model with strain-softening and reinforcement is modeled as elastic bars that are embedded into the concrete domain. Adjoint...... sensitivity analysis is derived in complete consistency with respect to path-dependency and the nonlocal model. Classical truss topology optimization based on the ground structure approach is applied to determine the optimal topology and cross-sections of the reinforcement bars. This approach facilitates...

  8. Analysis of time-dependent reliability of degenerated reinforced concrete structure

    Directory of Open Access Journals (Sweden)

    Zhang Hongping

    2016-07-01

    Full Text Available Durability deterioration of structure is a highly random process. The maintenance of degenerated structure involves the calculation of the reliability of time-dependent structure. This study introduced reinforced concrete structure resistance decrease model and related statistical parameters of uncertainty, analyzed resistance decrease rules of corroded bending element of reinforced concrete structure, and finally calculated timedependent reliability of the corroded bending element of reinforced concrete structure, aiming to provide a specific theoretical basis for the application of time-dependent reliability theory.

  9. Analytical Model for Fictitious Crack Propagation in Reinforced Concrete Beams without Debonding

    DEFF Research Database (Denmark)

    Ulfkjær, J. P.; Brincker, Rune

    1994-01-01

    , the crack growth is further simplified by introducing a continuous layer of springs at the midsection mainly representing a simplified material response around the fracture zone. In the reinforcement the strain condition is assumed to be equal to the strain condition in the concrete. the important question......The non-linear fracture mechanical problem of combined crack growth and reinforcement action is modelled by adopting a simplified fictitious crack model for concrete and a linear elastic-plastic action for the reinforcement. The softening relation of the concrete is assumed to be linear, however...

  10. Mineral-Based Bonding of Carbon FRP to Strengthen Concrete Structures

    DEFF Research Database (Denmark)

    Täljsten, Björn; Blanksvärd, T.

    2007-01-01

    The advantages of fiber-reinforced polymer (FRP) -strengthening have been shown time and again during the last decade. Several thousand structures retrofitted with FRPs exist worldwide. There are various reasons why the retrofit is needed, but it is not uncommon for the demands on the structure t...

  11. Experimental and finite element analysis of bond-slip in reinforced concrete

    Directory of Open Access Journals (Sweden)

    A. R. V. WOLENSKI

    Full Text Available Abstract The modeling of reinforced concrete structures has taken advantage of the increasing progress on Computational Mechanics, in such way that complex phenomena, such as cracking and crushing, creep, reinforcement yielding, steel-concrete bond loss, can be modeled in a reasonable realistic way, using the proper set of numerical and computational resources. Among several options, the ones based on the Finite Element Method (FEM allow complex analysis simulations of reinforced concrete structures, including the interaction of different nonlinear effects. This paper deals with the nonlinear finite element analysis of the bond-slip between reinforcing steel and concrete, taking into account an experimental study previously performed. The FEM analysis presented uses a combination of resources where the material behavior of concrete is described by the Microplane Constitutive Model, and an embedded reinforcement model is used to represent steel inside the concrete and take into account the effect of bond-slip. The FEM models were created using the INSANE (INteractive Structural ANalysis Environment computational system, open source software that has a set of FEM tools for nonlinear analysis of reinforced concrete structures. The correlations between numerical-experimentals results and several parameters validate the proposed combination of resources and identifies the significance of various effects on the response.

  12. Structural Engineering Properties of Fibre Reinforced Concrete Based On Recycled Glass Fibre Polymer (GFRP)

    OpenAIRE

    Adetiloye A; Ephraim M. E

    2015-01-01

    Glass fibre reinforced plastics (GFRP) based on resin recovered from recycling plastic waste has been shown to possess mechanical properties satisfying normative requirements. This paper investigates the flexural behavior of concrete beams reinforced with GFRP produced from resin recovered from recycled plastic wastes. A total of twelve of beams of sizes 150 ×150 ×900mm and 100 × 100 × 500mm reinforced with GFRP made from recycled glass fibre reinforced polymer was tested. The fle...

  13. Fracture Behavior and Properties of Functionally Graded Fiber-Reinforced Concrete

    Science.gov (United States)

    Roesler, Jeffery; Bordelon, Amanda; Gaedicke, Cristian; Park, Kyoungsoo; Paulino, Glaucio

    2008-02-01

    In concrete pavements, a single concrete mixture design is selected to resist mechanical loading without attempting to adversely affect the concrete pavement shrinkage, ride quality, or noise attenuation. An alternative approach is to design distinct layers within the concrete pavement surface which have specific functions thus achieving higher performance at a lower cost. The objective of this research was to address the structural benefits of functionally graded concrete materials (FGCM) for rigid pavements by testing and modeling the fracture behavior of different combinations of layered plain and synthetic fiber-reinforced concrete materials. Fracture parameters and the post-peak softening behavior were obtained for each FGCM beam configuration by the three point bending beam test. The peak loads and initial fracture energy between the plain, fiber-reinforced, and FGCM signified similar crack initiation. The total fracture energy indicated improvements in fracture behavior of FGCM relative to full-depth plain concrete. The fracture behavior of FGCM depended on the position of the fiber-reinforced layer relative to the starter notch. The fracture parameters of both fiber-reinforced and plain concrete were embedded into a finite element-based cohesive zone model. The model successfully captured the experimental behavior of the FGCMs and predicted the fracture behavior of proposed FGCM configurations and structures. This integrated approach (testing and modeling) demonstrates the viability of FGCM for designing layered concrete pavements system.

  14. Foundation Design for a High Bay Warehouse with a Steel Fibre Reinforced Concrete Slab

    DEFF Research Database (Denmark)

    Kasper, T.; Sørensen, Carsten Steen; Nielsen, J. B.

    2008-01-01

    concrete slabs, while a 69 x 77 m and 40 cm thick steel fibre reinforced concrete (SFRC) slab forms the inner part of the foundation. Steel fibre reinforcement has been chosen mainly due to approximately 15 % lower construction costs than a comparable solution with conventional rebar reinforcement......The high bay warehouse at the Carlsberg brewery in Fredericia, Denmark, is 40 m high and is founded with a 83 x 116 m foundation slab on clay till and sand layers. Due to the wind loads on the tall building, the edges of the foundation require 80 cm and 60 cm thick conventionally reinforced...

  15. Finite Element Reliability Analysis of Chloride Ingress into Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Frier, Christian; Sørensen, John Dalsgaard

    2007-01-01

    For many reinforced concrete structures corrosion of the reinforcement is an important problem since it can result in maintenance and repair actions. Further, a reduction of the load-bearing capacity can occur. In the present paper the Finite Element Reliability Method (FERM) is employed for obta......For many reinforced concrete structures corrosion of the reinforcement is an important problem since it can result in maintenance and repair actions. Further, a reduction of the load-bearing capacity can occur. In the present paper the Finite Element Reliability Method (FERM) is employed...

  16. A Probabilistic Model for Chloride-Ingress and Initation of Corrosion in Reinforced Concrete Structures

    DEFF Research Database (Denmark)

    Engelund, S.; Sørensen, John Dalsgaard

    1998-01-01

    value. In the present paper a statistical model by which the chloride content in a reinforced concrete structure can be predicted, is developed. The model parameters are estimated on the basis of measurements. The distribution of the time to initiation of corrosion can now be estimated by traditional......Corrosion of the reinforcement is a major problem for a large number of reinforced concrete structures because it can lead to a substantial decrease of the load-bearing capacity. One mode of corrosion initiation is that the chloride content around the reinforcement exceeds a critical threshold...

  17. Meso-mechanical Interfacial Behavior of Elbow Steel Fiber Reinforced Concrete

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yanru; JIANG Aifeng; XING Yongming; HUANG Janyong

    2012-01-01

    The strain distributions near the interface when the elbow steel fiber is pulled out from the half-mould concrete matrix are directly measured using a combined method of single fiber pull-out test and digital image correlation.Meanwhile,the real-time processes of the bonding,debonding and sliding at the interface are observed.The micro-mechanism of the strain localization in the failure process of interface when debonding occurs and the strengthening mechanism at the imbedded fiber are discussed.The experimental results show that the meso-scale strain localization gives rise to the localization of shear damage near the fiber interface.This strain localization characterized by the debonding process near the interface occurs,develops and moves gradually at an apparently regular interval.At the elbow part of the imbedded fiber,the peak value of the shearing stress occurs.But the primary debonding does not occur at this place because the strength of the shear damage is increased at the local area of the elbow part in the concrete,displaying an apparent reinforced effect at the end of the fiber.

  18. Strength Modeling of High-Strength Concrete with Hybrid Fibre Reinforcement

    Directory of Open Access Journals (Sweden)

    A. Ravichandran

    2009-01-01

    Full Text Available The low tensile strength and limited ductility, the unavoidable deficiency, of concrete can be overcome by the addition of fibres. High strength concrete (HSC of 60 MPa containing hybrid fibres, combination of steel and polyolefin fibres, at different volume fraction of 0.5, 1.0, 1.5 and 2.0% were compared in terms of compressive, splitting tensile strength and flexural properties with HSC containing no fibres. Test results showed that the fibres when used in hybrid form could result in enhanced flexural toughness compared to steel fibre reinforced concrete [HSFRC]. The compressive strength of the fibre-reinforced concrete reached maximum at 1.5% volume fractions and the splitting tensile strength and modulus of rupture improved with increasing volume fraction. Strength models were established to predict the compressive and splitting tensile strength and modulus of rupture of the fibre-reinforced concrete. The models give prediction matching the measurements.

  19. Experimental Study on Common and Steel Fiber Reinforced Concrete Under Dynamic Tensile Stress

    Institute of Scientific and Technical Information of China (English)

    董新龙; 陈江瑛; 高培正; 祁振林; 王永忠; 王永刚; 王礼立

    2004-01-01

    Split Hopkinson technique has been developed to test the strength of common concrete and steel fiber reinforced concrete under dynamic tensile stress. Two types of test methods are considered, the splitting tensile test and a modified spalling test in which a specimen is loaded under uniaxial stress. The result shows that the dynamic strength enhancement of concrete is remarkable by using the reinforcing fiber. But for the common concrete, the base of compressive strength seems to show little effect on the tensile strength under dynamic loading. The experimental results also show that the resistance to tensile fracture of the steel fiber reinforced concrete for C100-mix is higher than those of C40-mix.

  20. Potential Effects of Corrosion Damage on the Performance of Reinforced Concrete Member

    Directory of Open Access Journals (Sweden)

    Mohd Noh Hamidun

    2016-01-01

    Full Text Available Corrosion of steel in reinforced concrete is one of the most serious issues for the owners. The main consequences of this phenomenon include loss of cross section of steel area, induced the expansive pressure which caused cracking of concrete, spalling and delaminating of the concrete cover. Thus, it reduces the bond strength between steel reinforcing bar and concrete, and deteriorates the strength of whole structure. In this study, a non-linear finite element analysis was conducted to investigate the potential effects of corrosion damage. A series of corroded reinforced concrete cylinder is used in the parametric study to assess the influence of different level of corrosion to the structural performance. As a result, a clear picture of corrosive expansion was investigated and the relationship between the expansive pressure and the degree of corrosion was identified to be the important factors of the structural deterioration.

  1. Evaluation of Tensile Strength of Unresin Continuous Carbon Fiber Cables as Tensile Reinforcement for Concrete Structures

    OpenAIRE

    Ohta, Toshiaki; Djamaluddin, rudy; Seo, SungTag; Sajima, Takao; Harada, Koji

    2002-01-01

    As a tensile reinforcement of a concrete structure member, tensile strength of Unresin Continuous Carbon Fiber (UCCF) cables should be stated clearly. It has been reported that, through direct tensile test, tensile capacity of UCCF cables ranged from 30%

  2. Investigation of Corrosion and Cathodic Protection in Reinforced Concrete. II: Properties of Steel Surface Layers

    NARCIS (Netherlands)

    Koleva, D.A.; De Wit, J.H.W.; Van Breugel, K.; Lodhi, Z.F.; Ye, G.

    2007-01-01

    The present study explores the formation of corrosion products on the steel surface (using as-received low carbon construction steel) in reinforced concrete in conditions of corrosion and subsequent transformation of these layers in conditions of cathodic protection (CP).

  3. Effect of steel reinforcement with different degree of corrosion on degeneration of mechanical performance of reinforced concrete frame joints

    Directory of Open Access Journals (Sweden)

    Wu Xu

    2016-02-01

    Full Text Available Beam-column joints which shoulders high-level and vertical shearing effect that maintains balance of beam and column end is the major component influencing the performance of the whole framework. Post earthquake investigation suggests that collapse of frame structure is induced by failure of joints in most cases. Thus, beam-column joints must have strong bearing capacity and good ductility, and reinforced concrete structure just meets the above requirement. But corrosion caused by long time use of reinforced concrete framework will lead to degeneration of mechanical performance of joints. To find out the rule of effect of steel reinforcement with different corrosion rate on degeneration of bearing capacity of reinforced concrete framework joints, this study made a nonlinear numerical analysis on fifteen models without stirrup in the core area of reinforced concrete frame joints using displacement method considering axial load ratio of column end and constraint condition. This work aims to find out the key factor that influences mechanical performance of joints, thus to provide a basis for repair and reinforcement of degenerated framework joints.

  4. Rupture Directivity Effect on Seismic Vulnerability of Reinforced Concrete Bridge

    Science.gov (United States)

    Shirazian, Shadi; Nouri, Gholamreza; Ghayamghamian, Mohamadreza

    2017-04-01

    Earthquake catastrophes menace humans` lives and assets. Although earthquakes are inevitable, damage is not. To remedy this situation, significant amount of research is conducted in order to assess the performance of existent man-made structures, particularly infrastructures such as bridges which play a vital role in post earthquake services. The results can be used for assessing retrofit prioritization for structures and as a basis for economic loss estimations. The research presented here determines the vulnerability of a common typical two-span reinforced concrete bridge by generating fragility curves. Near-fault ground motions are different from ordinary ground motions, often containing strong coherent dynamic long-period pulses and permanent ground displacements. Here special attention is given to this type of ground motions, and their effects on the seismic behavior of structure are compared with ordinary motions. The results show near-fault ground motions exacerbate the seismic vulnerability of a bridge by about 68% in comparison with near-field ground motions. In other words, near-source ground motions with forward directivity effect are more dangerous.

  5. Modelling Blast Effects on a Reinforced Concrete Bridge

    Directory of Open Access Journals (Sweden)

    Markellos Andreou

    2016-01-01

    Full Text Available The detailed investigation of blast phenomena and their catastrophic effects on existing structures are the main objectives of the present paper. It is well known that blast phenomena may be characterized by significant complexity, often involving complicated wave propagation effects as well as distinguishable material behaviors. Considering the above and in an attempt to provide a simplified modelling approach for the simulation of blast effects, a novel procedure is presented herein based on well-established methodologies and common engineering practices. In the above framework, firstly, the “predominant” deformation shape of the structure is estimated based on elastic finite element simulations under blast loads and then the structural response of the system is evaluated as a result of common computational beam-element tools such as displacement-based pushover analysis. The proposed methodology provides an immediate first estimation of the structural behavior under blast loads, based on familiar engineering procedures. A two-span reinforced concrete bridge was thoroughly investigated and the results provide insightful information regarding the damage patterns and localization.

  6. Using New Coating Materials for Corrosion Prevention of Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Elshami Ahmed

    2014-04-01

    Full Text Available Deterioration of reinforcing concrete structures is a common problem among all the Mediterranean countries. To protect steel from corrosion, cobalt oxide with zinc oxide were successfully deposited on silica and alumina layer according to Core–shell theory. This theory based on depositing a surface layer of expensive efficient anticorrosive coating on a cheap extender expressing the bulk. The combination of both core and shell compounds led to the production of new coating with improved properties different from each of its individual components. These improved properties lead to change in the efficiency of protection properties of coating films containing these new coating. The objective of the present work is to prepare a new ecologically friendly natural and inorganic coating of Egyptian mix (kaolin and ceramic waste and zinc phosphate as corrosion inhibitors based on the solid–solid interaction to protect steel from corrosion in buildings construction. The results revealed that these new coating gives the best results in protecting steel substrates from corrosion especial in aggressive environment.

  7. Aftershock collapse vulnerability assessment of reinforced concrete frame structures

    Science.gov (United States)

    Raghunandan, Meera; Liel, Abbie B.; Luco, Nicolas

    2015-01-01

    In a seismically active region, structures may be subjected to multiple earthquakes, due to mainshock–aftershock phenomena or other sequences, leaving no time for repair or retrofit between the events. This study quantifies the aftershock vulnerability of four modern ductile reinforced concrete (RC) framed buildings in California by conducting incremental dynamic analysis of nonlinear MDOF analytical models. Based on the nonlinear dynamic analysis results, collapse and damage fragility curves are generated for intact and damaged buildings. If the building is not severely damaged in the mainshock, its collapse capacity is unaffected in the aftershock. However, if the building is extensively damaged in the mainshock, there is a significant reduction in its collapse capacity in the aftershock. For example, if an RC frame experiences 4% or more interstory drift in the mainshock, the median capacity to resist aftershock shaking is reduced by about 40%. The study also evaluates the effectiveness of different measures of physical damage observed in the mainshock-damaged buildings for predicting the reduction in collapse capacity of the damaged building in subsequent aftershocks. These physical damage indicators for the building are chosen such that they quantify the qualitative red tagging (unsafe for occupation) criteria employed in post-earthquake evaluation of RC frames. The results indicated that damage indicators related to the drift experienced by the damaged building best predicted the reduced aftershock collapse capacities for these ductile structures.

  8. Radiation exposure inside reinforced concrete buildings at Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Rhoades, W.A.; Childs, R.L.; Ingersoll, D.T.

    1989-05-01

    The biological effects on the residents of Hiroshima and Nagasaki due to initial-irradiation exposure during the nuclear attacks of World War II was recognized immediately as an important source of information. After the war, an extensive effort gathered data concerning the locations of individuals at the time of the attack and their subsequent medical histories. The data from personnel located in reinforced concrete buildings are particularly significant, since large groups of occupants received radiation injury without complications due to blast and thermal effects. In order to correlate the radiation dose with physiological effects, the dose to each individual must be calculated. Enough information about the construction of the buildings was available after the war to allow a radiation transport model to be constructed, but the accurate calculation of penetration into such large, thick-walled three dimensional structures was beyond the scope of computing technology until recently. Now, the availability of Cray vector computers and the development of a specially-constructed discrete ordinates transport code, TORT, have combined to allow the successful completion of such a study. This document describes the radiation transport calculations and tabulates the resulting doses by source component and individual case location. An extensive uncertainty analysis is also included. These data are to be used in another study as input to a formal statistical analysis, resulting in a new value for the LD50 dose, i.e., the dose at which the mortality risk is 50%. 55 refs., 67 figs., 70 tabs.

  9. Application of bamboo for flexural and shear reinforcement in concrete beams

    Science.gov (United States)

    Schneider, Nathan Alan

    As the developing world is industrializing and people migrate to cities, the need for infrastructure is growing quickly and concrete has become one of the most widely used construction materials. One poor construction practice observed widely across the developing world is the minimal use of reinforcement for concrete structures due to the high cost of steel. As a low-cost, high-performance material with good mechanical properties, bamboo has been investigated as an alternative to steel for reinforcing concrete. The goal of this research is to add to the knowledge base of bamboo reinforced concrete (BRC) by investigating a unique stirrup design and testing the lap-splicing of flexural bamboo reinforcement in concrete beams. Component tests on the mechanical properties of Moso bamboo (Phyllostachys edulis) were performed, including tensile tests and pull-out tests. The results of the component tests were used to design and construct 13 BRC beams which were tested under monotonic gravity loading in 3 and 4-point bending tests. Three types of beams were designed and tested, including shear controlled, flexure controlled, and lap-spliced flexure controlled beams. The test results indicated that bamboo stirrups increased unreinforced concrete beam shear capacities by up to 259%. The flexural bamboo increased beam capacities by up to 242% with an optimal reinforcement ratio of up to 3.9%, assuming sufficient shear capacity. Limitations of the bamboo reinforcement included water absorption as well as poor bonding capability to the concrete. The test results show that bamboo is a viable alternative to steel as tensile reinforcement for concrete as it increases the ultimate capacity of the concrete, allows for high deflections and cracks, and provides warning of impending structural failure.

  10. Experimental data of the static behavior of reinforced concrete beams at room and low temperature.

    Science.gov (United States)

    Mirzazadeh, M Mehdi; Noël, Martin; Green, Mark F

    2016-06-01

    This article provides data on the static behavior of reinforced concrete at room and low temperature including, strength, ductility, and crack widths of the reinforced concrete. The experimental data on the application of digital image correlation (DIC) or particle image velocimetry (PIV) in measuring crack widths and the accuracy and precision of DIC/PIV method with temperature variations when is used for measuring strains is provided as well.

  11. Bending Moment Decrease of Reinforced Concrete Beam Supported by Additional CFRP

    Directory of Open Access Journals (Sweden)

    Mykolas Daugevičius

    2011-04-01

    Full Text Available The calculation method of reinforced concrete beam with additional CFRP composite is proposed in this article. This method estimates tangential angular concrete deformations in tensioned beam layers between steel and bonded carbon fiber reinforced polymer. The horizontal slip of CFRP composite reduce beam bending moment capacity. An additional coefficient to reduce CFRP resultant force is necessary for better precision of bending moment capacity. Also, various calculation methods of bending moment capacity are considered. Article in Lithuanian

  12. Damage detection in reinforced concrete square slabs using modal analysis and artifical neural network

    OpenAIRE

    Ahmed, MS

    2016-01-01

    Reinforced concrete (RC) structures are usually subjected to various types of loadings, such as permanent, sustained and transient during their lifetime. Reinforced concrete slabs are one of the most fundamental structural elements in buildings and bridges, which might be exposed to unfavourable conditions such as, impaired quality control, lack of maintenance, adverse environmental effects, and inadequate initial design. Therefore, the resistant capacity of the affected elements would dramat...

  13. Experimental data of the static behavior of reinforced concrete beams at room and low temperature

    Directory of Open Access Journals (Sweden)

    M. Mehdi Mirzazadeh

    2016-06-01

    Full Text Available This article provides data on the static behavior of reinforced concrete at room and low temperature including, strength, ductility, and crack widths of the reinforced concrete. The experimental data on the application of digital image correlation (DIC or particle image velocimetry (PIV in measuring crack widths and the accuracy and precision of DIC/PIV method with temperature variations when is used for measuring strains is provided as well.

  14. Blast Design of Reinforced Concrete and Masonry Components Retrofitted with FRP

    Science.gov (United States)

    2010-07-01

    ultimate flexural and shear resistance of the upgraded walls. The methodology for estimating the flexural resistance of concrete and masonry components...recommended value not including any environmental effects or debonding The FRP reinforcement is typically applied to a concrete or masonry wall...have enough tensile and shear strength to transfer the force and develop the strength of the bonded FRP reinforcement . The durability of the

  15. The use of a sacrificial zinc anode for cathodic protection of steel in reinforced concrete

    Energy Technology Data Exchange (ETDEWEB)

    Hartman, R.B.; Hillier, W.H. [3M Co., St. Paul, MN (United States)

    1997-12-01

    The problem of corrosion of the reinforcing steel in concrete is recognized as a worldwide problem. In particular, these is extensive corrosion in residential and commercial balconies in tropical, coastal areas of the US, especially in Florida. A system of cathodic protection of reinforcing steel in concrete utilizing a sacrificial zinc anode and ionically conductive adhesive is described. Installation and monitoring of two condominium balconies in south Florida will be described, including instant-off and depolarization measurements over 18 months.

  16. The Reinforced Concrete Structure Reinforcement Technology%钢筋混凝土结构加固技术

    Institute of Scientific and Technical Information of China (English)

    李孝余

    2014-01-01

    This article mainly from the carbon fiber reinf-orcement technology, grouting reinforcement technology, che.-mical y-planted steel bars technology, change the stress system, etc. to discuss the reinforced concrete structure reinforcement technology and carries on the comprehensive comparison of these methods.%本文主要从碳纤维加固技术、注浆加固技术、化学植筋技术、改变受力体系等方面,论述了钢筋混凝土结构加固技术,并对这几种方法进行了全面对比。

  17. Combination Of The Non-Destructive Methods For Evaluating The Quality Of Concrete Used In Structures In Reinforced Concrete

    Directory of Open Access Journals (Sweden)

    Mr. R. OBAD

    2014-12-01

    Full Text Available The study is aboutthe use and comparison of three non-destructive methods (dynamic auscultation, sclerometric auscultation and auscultation by RADAR (Radio Detecting and Ranging to monitor and assess the quality of concrete. Samples of reinforced concrete panels, dimensions 200x100x30 cm of concrete dosed at 350 kg/m3 with diverse E/C ratio were achieved, conserved in the laboratory and subjected to various non-destructive test. The synthesis of the results obtained by auscultation RADAR shows a decrease in the propagation speed of the electromagnetic wave with an increase of the E/C ratio and a decrease in resistance of concrete values measured and confirmed by other non-destructive techniques (sclerometric and dynamic auscultations. This shows that more the dielectric constant is high, morethe concrete resistance is reduced, and conversely the opposite.

  18. Bond Strength between Hybrid Fiber-Reinforced Lightweight Aggregate Concrete Substrate and Self-Compacting Concrete as Topping Layer

    Directory of Open Access Journals (Sweden)

    Slamet Widodo

    2017-01-01

    Full Text Available Structural performance evaluation of composite concrete slabs that were constructed using partially precast concreting system which utilized Hybrid Fiber-Reinforced Lightweight Aggregate Concrete (HyFRLWAC as stay in-place formwork and self-compacting concrete (SCC as topping layer was conducted in this research. This paper focused on determining the appropriate strength limit criteria of interface between two different concrete layers. The tensile strength was tested using pull-off test, while concrete cohesion was investigated based on modified bisurface shear test, and dual L-shaped shear test was used to determine the effect of normal force on the shear strength of concrete interface. Sample variants were designed based on the substrate surface conditions, compressive strength of the topping layer, and magnitude of perpendicular normal force acting on interface area. The substrate surfaces were prepared in as-placed and grooved conditions for tensile test, cohesion, and shear strength test. Test results indicate that tensile strength, cohesion, and shear strength of the concrete interface are affected by surface condition of the substrate, compressive strength of the topping layer, and the normal force acting perpendicularly on the concrete interface area. Proposed formulation for bond strength prediction between HyFRLWAC as substrate and SCC as topping layer is also presented in this paper.

  19. 77 FR 39254 - Steel Concrete Reinforcing Bar From Belarus, China, Indonesia, Latvia, Moldova, Poland, and...

    Science.gov (United States)

    2012-07-02

    ..., Deputy Agency Ethics Official, at 202-205-3088. Limited disclosure of business proprietary information... Ukraine; Institution of Five-Year Reviews Concerning the Antidumping Duty Orders on Steel Concrete... determine whether revocation of the antidumping duty orders on steel concrete reinforcing bar from Belarus...

  20. Resistance to Corrosion of Reinforcement of High Volume Fly Ash Concrete

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, S. O.; Bae, S. H.; Lee, H. J. [Andong National University, Andong (Korea, Republic of); Lee, K. M. [Sungkyunkwan University, Suwon (Korea, Republic of); Jung, S. H. [Korea Confirmity Laboratories, Seoul (Korea, Republic of)

    2014-12-15

    Due to the increasing of interest about the eco-friendly concrete, it is increased to use concretes containing by-products of industry such as fly ash(FA), ground granulated blast furnace slag(GGBFS), silica fume(SF), and etc. Especially, these are well known for improving the resistances to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance against corrosion of reinforcement of high volume fly ash(HVFA) concrete which is replaced with high volume fly ash for cement volume. For this purpose, the concrete test specimens were made for various strength level and replacement ratio of FA, and then the compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91, and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that the compressive strength of HVFA concrete was decreased with increasing replacement ratio of FA but long-term resistances against reinforcement corrosion and chloride ion penetration of that were increased.

  1. The Relationship between Rebar-Debonding and Cracking in Reinforced Concrete

    DEFF Research Database (Denmark)

    Thybo, Anna Emilie A.; Stang, Henrik; Olesen, John Forbes

    2012-01-01

    A mechanical model has been used to evaluate the rebar-concrete debonding length and Crack Mouth Opening Displacement (CMOD) in reinforced concrete. The modelling is based on the theory of the fictitious crack. It is shown that there is a non-trival relationship between the debonding length...

  2. The role of concrete resistivity in chloride-induced macro-cell corrosion of reinforcement

    OpenAIRE

    Hornbostel, Karla

    2015-01-01

    Norwegian concrete structures are exposed to salt contamination from both sea water and de-icing salts. Chlorides penetrate the concrete cover and initiate corrosion of the reinforcement. The deterioration process can propagate at high rates and endanger serviceability and structural safety. Concrete resistivity is usually assumed to correlate closely with the corrosion process, and its measurement is in principle simple and costefficient, and widely recommended to support serv...

  3. Concrete mechanics. Part A: Theory and experiments on the mechanical behavior of cracks in plain and reinforced concrete subjected to shear loading

    Science.gov (United States)

    Walraven, J. C.; Reinhardt, H. W.

    The mechanism or transmission of forces across cracks whose faces are subjected to shear displacements are investigated. This mechanism is achieved by interaction of several components: axial and transverse stiffness (dowel action) of the reinforcement and direct transfer of force between the rough concrete crack faces, generally denoted by the term 'aggregate interlock'. Experimental research and the derivation of a theoretical model gave insight into the phenomenon. Tests were carried out on precracked shear specimens. Variables in the tests were the type of reinforcement (embedded reinforcing bars, external restraint bars), the concrete strength, the type of the concrete (sand gravel concrete, lightweight concrete), the grading of the concrete (continuous discontinuous), the scale of the concrete, and the initial crack width. Measurements were carried for determining the shear force, the crack displacements and, for the specimens with external reinforcement, the force in the restraining bars.

  4. Analysis of concrete targets with different kinds of reinforcements subjected to blast loading

    Science.gov (United States)

    Oña, M.; Morales-Alonso, G.; Gálvez, F.; Sánchez-Gálvez, V.; Cendón, D.

    2016-05-01

    In this paper we describe an experimental campaign carried out to study and analyse the behaviour of concrete slabs when subjected to blast loading. Four different types of concrete have been tested: normal strength concrete with steel rebar, normal strength concrete with steel rebar retrofitted with Kevlar coating, steel fibre reinforced concrete (SFRC) and polypropylene fibre reinforced concrete (PFRC). The major asset of the experimental setup used is that it allows to subject up to four specimens to the same blast load what, besides being cost effective, makes possible to have a measure of the experimental scatter. The results of SFRC and PFRC concretes have been analysed by using a previously developed material model for the numerical simulation of concrete elements subjected to blast. The experimental campaign and preliminary results of this numerical analysis show how the high strain rates, in spite of improving the mechanical properties of these kinds of fibre reinforced concretes, lead to an embrittlement of the material, which may be dangerous from the point of view of the structural behaviour.

  5. Bond characteristics of steel fiber and deformed reinforcing steel bar embedded in steel fiber reinforced self-compacting concrete (SFRSCC)

    Science.gov (United States)

    Aslani, Farhad; Nejadi, Shami

    2012-09-01

    Steel fiber reinforced self-compacting concrete (SFRSCC) is a relatively new composite material which congregates the benefits of the self-compacting concrete (SCC) technology with the profits derived from the fiber addition to a brittle cementitious matrix. Steel fibers improve many of the properties of SCC elements including tensile strength, ductility, toughness, energy absorption capacity, fracture toughness and cracking. Although the available research regarding the influence of steel fibers on the properties of SFRSCC is limited, this paper investigates the bond characteristics between steel fiber and SCC firstly. Based on the available experimental results, the current analytical steel fiber pullout model (Dubey 1999) is modified by considering the different SCC properties and different fiber types (smooth, hooked) and inclination. In order to take into account the effect of fiber inclination in the pullout model, apparent shear strengths (τ (app)) and slip coefficient (β) are incorporated to express the variation of pullout peak load and the augmentation of peak slip as the inclined angle increases. These variables are expressed as functions of the inclined angle (ϕ). Furthurmore, steel-concrete composite floors, reinforced concrete floors supported by columns or walls and floors on an elastic foundations belong to the category of structural elements in which the conventional steel reinforcement can be partially replaced by the use of steel fibers. When discussing deformation capacity of structural elements or civil engineering structures manufactured using SFRSCC, one must be able to describe thoroughly both the behavior of the concrete matrix reinforced with steel fibers and the interaction between this composite matrix and discrete steel reinforcement of the conventional type. However, even though the knowledge on bond behavior is essential for evaluating the overall behavior of structural components containing reinforcement and steel fibers

  6. Application of artificial neural networks to predict the deflections of reinforced concrete beams

    Science.gov (United States)

    Kaczmarek, Mateusz; Szymańska, Agnieszka

    2016-06-01

    Nonlinear structural mechanics should be taken into account in the practical design of reinforced concrete structures. Cracking is one of the major sources of nonlinearity. Description of deflection of reinforced concrete elements is a computational problem, mainly because of the difficulties in modelling the nonlinear stress-strain relationship of concrete and steel. In design practise, in accordance with technical rules (e.g., Eurocode 2), a simplified approach for reinforced concrete is used, but the results of simplified calculations differ from the results of experimental studies. Artificial neural network is a versatile modelling tool capable of making predictions of values that are difficult to obtain in numerical analysis. This paper describes the creation and operation of a neural network for making predictions of deflections of reinforced concrete beams at different load levels. In order to obtain a database of results, that is necessary for training and testing the neural network, a research on measurement of deflections in reinforced concrete beams was conducted by the authors in the Certified Research Laboratory of the Building Engineering Institute at Wrocław University of Science and Technology. The use of artificial neural networks is an innovation and an alternative to traditional methods of solving the problem of calculating the deflections of reinforced concrete elements. The results show the effectiveness of using artificial neural network for predicting the deflection of reinforced concrete beams, compared with the results of calculations conducted in accordance with Eurocode 2. The neural network model presented in this paper can acquire new data and be used for further analysis, with availability of more research results.

  7. Demonstration and Validation of a Lightweight Composite Bridge Deck Technology as an Alternative to Reinforced Concrete

    Science.gov (United States)

    2016-08-01

    78 Figure 103. Extensive missing grout revealed after steel strips removed. .......................... 79 Figure 104. Grout leaking through caulk...ERDC/CERL TR-16-16 79 Figure 103. Extensive missing grout revealed after steel strips removed. Figure 104. Grout leaking through caulk. ERDC...Abstract Cyclic loading and weathering of reinforced concrete bridge decks cause corrosion of reinforcement steel , which leads to cracking, potholes

  8. Articularities of Analysis and Behaviour of Concrete Beams Reinforced with Fibrous Polymer Composite Bars

    Directory of Open Access Journals (Sweden)

    N. Ţăranu

    2006-01-01

    Full Text Available Traditional steel based reinforcement systems for concrete elements are facing with serious problems mainly caused by corrosion due to chemically aggressive environments and salts used in deicing procedures, especially in case of bridge steel reinforced concrete girders. Also in some cases special applications require structural members with magnetic transparency. An alternative to this major problem has recently become the use of fiber reinforced polymer (FPR composite bars as internal reinforcement for concrete beams. The particularities of their mechanical properties are making the design process a difficult task for engineers, numerous research centers being involved in correcting this situation. The general aspects concerning the conceiving of FR.P reinforced concrete beams are firstly analyzed, compared to those reinforced with steel bars. Some results of a Finite Element Analysis, as part of a complex program which also implies full scale testing of FRP reinforced beams subjected to bending, are given and discussed in the paper. The low elasticity modulus presented by glass fiber reinforced polymer (GFRP bars does not justify its use from structural point of view when deflection is the limiting condition but for corrosive resistance reasons and special electromagnetic properties this system can be promoted.

  9. Assessment of cracks in reinforced concrete by means of electrical resistance and image analysis

    NARCIS (Netherlands)

    Pacheco, J.; Šavija, B.; Schlangen, E.; Polder, R.B.

    2014-01-01

    The durability of cracked reinforced concrete is a serious concern in the construction industry. Cracks represent fast routes for chloride penetration, which can result in reinforcement corrosion. Bending or tapered cracks have the characteristic of being wider at the surface and becoming narrower t

  10. Influence of Basalt FRP Mesh Reinforcement on High-Performance Concrete Thin Plates at High Temperatures

    DEFF Research Database (Denmark)

    Hulin, Thomas; Lauridsen, Dan H.; Hodicky, Kamil;

    2015-01-01

    A basalt fiber–reinforced polymer (BFRP) mesh was introduced as reinforcement in high-performance concrete (HPC) thin plates (20–30 mm) for implementation in precast sandwich panels. An experimental program studied the BFRP mesh influence on HPC exposed to high temperature. A set of standard furn...

  11. Review of Japanese recommendations on design and construction of different classes of fiber reinforced concrete and application examples

    DEFF Research Database (Denmark)

    Uchida, Yuichi; Fischer, Gregor; Hishiki, Yoshihiro

    2008-01-01

    Reinforced Cement Composites (HPFRCC) with strain hardening and multiple cracking behavior, and Ultra High-strength Fiber Reinforced concrete (UFC) with increased tensile strength. The recommendations on the design, production, and application of these classes of fiber reinforced concrete have been...

  12. An application of asymmetrical glass fibre-reinforced plastics for the manufacture of curved fibre reinforced concrete

    OpenAIRE

    Funke, Henrik; Gelbrich, Sandra; Ulke-Winter , Lars; Kroll, Lothar; Petzoldt, Carolin

    2015-01-01

    There was developed a novel technological and constructive approach for the low-cost production of curved freeform formworks, which allow the production of single and double-curved fibre reinforced concrete. The scheduled approach was based on a flexible, asymmetrical multi-layered formwork system, which consists of glass-fibre reinforced plastic (GFRP). By using of the unusual anisotropic structural behavior, these GFRP formwork elements permitted a specific adjustment of defined curvature. ...

  13. Calculating the Carrying Capacity of Flexural Prestressed Concrete Beams with Non-Metallic Reinforcement

    Directory of Open Access Journals (Sweden)

    Mantas Atutis

    2011-04-01

    Full Text Available The article reviews moment resistance design methods of prestressed concrete beams with fibre-reinforced polymer (FRP reinforcement. FRP tendons exhibit linear elastic response to rupture without yielding and thus failure is expected to be brittle. The structural behaviour of beams prestressed with FRP tendons is different from beams with traditional steel reinforcement. Depending on the reinforcement ratio, the flexural behaviour of the beam can be divided into several groups. The numerical results show that depending on the nature of the element failure, moment resistance calculation results are different by using reviewed methods. It was found, that the use of non-metallic reinforcement in prestressed concrete structures is effective: moment capacity is about 5% higher than that of the beams with conventional steel reinforcement.Article in Lithuanian

  14. Crack elongation and its width of large depth reinforced concrete beams

    Institute of Scientific and Technical Information of China (English)

    GUAN Jun-feng; ZHAO Shun-bo; HUANG Cheng-kui

    2010-01-01

    In order to meet the requirement of structural inspection,the crack spacing and crack width at various heights in the tensile zone of six large depth reinforced concrete beams were measured under several loading levels of serviceability state.The effects of the depth of normal section beams on the crack spacing and crack width were analyzed,and the modified model is proposed for calculating the average crack spacing by thinking about the depth of normal section,the reinforcement arrangement and the effective reinforcement ratio.The relationships of crack widths at any position in the tensile zone and at the reinforcement level on the side surface of beam were studied.By theoretical and statistical analysis,a method is proposed to calculate the ratios of crack widths between any position and the reinforcement level on the side surface of large depth reinforced concrete beams.

  15. Tensile properties of glass/natural jute fibre-reinforced polymer bars for concrete reinforcement

    Science.gov (United States)

    Han, J. W.; Lee, S. K.; Kim, K. W.; Park, C. G.

    2015-12-01

    The tensile performance of glass/natural jute fibre-reinforced polymer (FRP) bar, intended for concrete reinforcement was evaluated as a function of volume fraction of natural jute fibre. Natural jute fibre, mixed at a ratio of 7:3 with vinyl ester, was surface-treated with a silane coupling agent and used to replaced glass fibre in the composite in volume fractions of 0%, 30%, 50%, 70%, and 100%. The tensile load-displacement curve showed nearly linear elastic behaviour up to 50% natural jute fibre, but was partially nonlinear at a proportion of 70%. However, the glass/natural jute FRP bars prepared using 100% natural jute fibre showed linear elastic behaviour. Tensile strength decreased as the natural jute fibre volume fraction increased because the tensile strength of natural jute fibre is much lower than that of glass fibre (about 1:8.65). The degree of reduction was not proportional to the natural jute fibre volume fraction due to the low density of natural jute fibre (1/2 that of glass fibre). Thus, as the mix proportion of natural jute fibre increased, the amount (wt%) and number of fibres used also increased.

  16. Effectiveness of concrete to protect steel reinforcement from corrosion in marine structures

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    A laboratory evaluation of how variations in cover design and properties determine its effectiveness in controlling corrosion in reinforced concretes in marine structures is described. The effect of concrete type and composition on chloride ingress and corrosion rate was studied for four simulated marine environments. Contrary to expectation, significant corrosion did not take place in reinforcement placed at 30 mm cover after 30 months exposure, even in concretes of lower strengths and higher water/cement ratios than mixes employed in the North Sea. Unexpected crevice corrosion let to the exclusion of electrochemical data and restricted the opportunity of correlating the properties of the cover with the onset and rate of corrosion of reinforcement. The project did, however, provide valuable data on in situ strength, moisture content, permeability, resistivity, carbonation and rate of chloride ingress. Limited data is also available on the pore structure of the cover and its oxygen diffusion characteristics. It is emphasised that all results refer to uncracked concrete. (author).

  17. Minimum Reinforcement in Concrete Structures under Restrained Shrinkage and Thermal Actions

    DEFF Research Database (Denmark)

    Christiansen, Morten Bo; Nielsen, Mogens Peter

    1999-01-01

    The present paper deals with minimum reinforcement to ensure limitation of crack widths in concrete structures subjected to small imposed strains, such as those from restrained shrinkage or thermal actions. A theory is presented, which models the behaviour of a tensile member from zero load...... to first yielding of reinforcement. The theory takes into account the formation of each crack. However, concluding the paper, a simple design formula is given, which provides the amount of reinforcement, necessary to ensure a given crack width....

  18. Punching strengthen

    Directory of Open Access Journals (Sweden)

    Hazem M.F. Elbakry

    2015-12-01

    Full Text Available An experimental and analytical study on the punching strengthening of reinforced concrete two-way slabs using external steel plates is presented. Five reinforced concrete square slabs of 100 mm thickness were tested over simply supported four sides of 1000 mm span under central square patch load of 100 mm size up to failure. One control slab was tested without strengthening; however, four tested slabs were strengthened using four configurations of square steel plates provided with steel anchor shear studs. Such configurations considered two different plate thickness, two plate side dimensions and different arrangement and diameter of shear studs. The strengthened four slabs showed improved stiffness and punching shear capacity. The magnitude of improvement depended on the plate dimensions and the studs diameter and arrangement. An analytical approach was proposed for predicting the punching shear strength increase due to using the strengthening steel plate. The proposed approach was applied to the tested specimens with the use of the punching shear strength equations adopted by several codes of practice and proved to be in good agreement with the test results. Generally, this research presented a practical strengthening concept that can be used to increase the punching shear capacity of two-way slabs.

  19. The 2011 Earthquake in Simav, Turkey and Seismic Damage to Reinforced Concrete Buildings

    Directory of Open Access Journals (Sweden)

    Yücel Güney

    2013-02-01

    Full Text Available Reinforced concrete buildings suffered significant damage in the region affected by the 29 May 2011 earthquake in Simav (Kutahya, Turkey. Typical building damage is classified and potential causes of damage are investigated. Reinforced concrete moment resisting frames with hollow brick infill walls are the most common structural system in and around the Simav city center while masonry construction is common in rural areas. Although the Simav earthquake, with a magnitude of 5.7 to 5.9, can be classified as a moderate earthquake, many buildings experienced damage varying from frequent diagonal cracking and brittle failure of infill walls to collapse or severe damage to frames due to short columns, soft stories or other reasons including insufficient or poor detailing of reinforcement. This study investigates and presents the seismicity of the region, characteristics of the measured ground motions, seismic load demands including response spectra, and damage mechanisms, potential causes and classification of observed damage in reinforced concrete buildings.

  20. Heavy vehicle simulator (HVS) evaluation of load transfer efficiency and continuously reinforced concrete inlays on the N3 near Pietermartizburg

    CSIR Research Space (South Africa)

    Du Plessis, L

    2006-07-01

    Full Text Available The paper addresses two different heavy Vehicle Simulator (HVS) studies conducted on concrete: Load transfer through aggregate interlock and the use of dowels and the evaluation of the performance of an in-service continuously reinforced concrete...