WorldWideScience

Sample records for regulatory agencies dosimetry

  1. Regulatory agencies and regulatory risk

    OpenAIRE

    Knieps, Günter; Weiß, Hans-Jörg

    2008-01-01

    The aim of this paper is to show that regulatory risk is due to the discretionary behaviour of regulatory agencies, caused by a too extensive regulatory mandate provided by the legislator. The normative point of reference and a behavioural model of regulatory agencies based on the positive theory of regulation are presented. Regulatory risk with regard to the future behaviour of regulatory agencies is modelled as the consequence of the ex ante uncertainty about the relative influence of inter...

  2. Survey of international personnel radiation dosimetry programs

    International Nuclear Information System (INIS)

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables

  3. Quality audit service of the IAEA for radiation processing dosimetry

    International Nuclear Information System (INIS)

    Mehta, K.; Girzikowsky, R.

    1996-01-01

    The mandate of the International Atomic Energy Agency includes assistance to Member States to establish nuclear technologies safely and effectively. In pursuit of this, a quality audit service for dosimetry relevant to radiation processing was initiated as a key element of the High-Dose Standardization Programme of the IAEA. The standardization of dosimetry for radiation processing provides a justification for the regulatory approval of irradiated products and their unrestricted international trade. In recent times, the Agency's Dosimetry Laboratory has placed concentrated effort towards establishing a quality assurance programme based on the ISO 9000 series documents. The need for reliable and accurate dosimetry for radiation processing is increasing in Member States and we can envisage a definite role for the SSDLs in such a programme. (author). 10 refs, 3 figs

  4. Regulatory Powers in Public Procurement Law of Peruvian Administrative Agencies

    Directory of Open Access Journals (Sweden)

    Juan Carlos Morón Urbina

    2017-12-01

    Full Text Available Peruvian law has explicitly recognized regulatory powers to administrative agencies, which allows them to have a preponderant role in the production of rules in public procurement. Although these delegations of legislative authority are positively defined, distortions in the system of legal sources arise when agencies exceed delegated powers or when measures issued by administrative entities are mistaken for regulations. This paper aims to identify regulatory powers of Peruvian administrative agencies, as well as the regulatory measures they issue, and their relation with other sources of law.

  5. Performance testing of dosimetry processors, status of NRC rulemaking for improved personnel dosimetry processing, and some beta dosimetry and instrumentation problems observed by NRC regional inspectors

    International Nuclear Information System (INIS)

    Dennis, N.A.; Kinneman, J.D.; Costello, F.M.; White, J.R.; Nimitz, R.L.

    1983-01-01

    Early dosimetry processor performance studies conducted between 1967 and 1979 by several different investigators indicated that a significant percentage of personnel dosimetry processors may not be performing with a reasonable degree of accuracy. Results of voluntary performance testing of US personnel dosimetry processors against the final Health Physics Society Standard, Criteria for Testing Personnel Dosimetry Performance by the University of Michigan for the Nuclear Regulatory Commission (NRC) will be summarized with emphasis on processor performance in radiation categories involving beta particles and beta particles and photon mixtures. The current status of the NRC's regulatory program for improved personnel dosimetry processing will be reviewed. The NRC is proposing amendments to its regulations, 10 CFR Part 20, that would require its licensees to utilize specified personnel dosimetry services from processors accredited by the National Voluntary Laboratory Accreditation Program of the National Bureau of Standards. Details of the development and schedule for implementation of the program will be highlighted. Finally, selected beta dosimetry and beta instrumentation problems observed by NRC Regional Staff during inspections of NRC licensed facilities will be discussed

  6. In Vitro Exposure Systems and Dosimetry Assessment Tools ...

    Science.gov (United States)

    In 2009, the passing of The Family Smoking Prevention and Tobacco Control Act facilitated the establishment of the FDA Center for Tobacco Products (CTP) and gave it regulatory authority over the marketing, manufacture and distribution of tobacco products, including those termed “modified risk”. On 4-6 April 2016, the Institute for In Vitro Sciences, Inc. (IIVS) convened a workshop conference titled “In Vitro Exposure Systems and Dosimetry Assessment Tools for Inhaled Tobacco Products” to bring together stakeholders representing regulatory agencies, academia, and industry to address the research priorities articulated by the FDA CTP. Specific topics were covered to assess the status of current in vitro smoke and aerosol/vapor exposure systems, as well as the various approaches and challenges to quantifying the complex exposures, in in vitro pulmonary models developed for evaluating adverse pulmonary events resulting from tobacco product exposures. The four core topics covered were, 1) Tobacco Smoke And E-Cigarette Aerosols, 2) Air-Liquid Interface-In Vitro Exposure Systems, 3) Dosimetry Approaches For Particles And Vapors; In Vitro Dosimetry Determinations and 4) Exposure Microenvironment/Physiology Of Cells. The two and a half day workshop included presentations from 20 expert speakers, poster sessions, networking discussions, and breakout sessions which identified key findings and provided recommendations to advance these technologies. Here, we will re

  7. Participation of the regional reference center for dosimetry of Argentina in the personnel dosimetry intercomparison for Latin America

    International Nuclear Information System (INIS)

    Alvarez, P.; Lindner, C.; Montano, R.G.; Saravi, M.

    1998-01-01

    Full text: A Regional Personnel Dosimetry Intercomparison was organized in the Regional Reference Center for Dosimetry (CRRD), in agreement with the International Atomic Energy Agency (IAEA) and the Nuclear Regulatory Authority (ARN), with the participation of 9 countries of Latin America. For dosimeter irradiations, X-ray, 60 Co γ-ray and 137 Cs γ-ray beams were used during the intercomparison. The air kerma rate was measured with the Secondary Standard NE 2560 and NE 2561 ionisation chamber. In compliance with ISO 4037 guideline, the wide spectrum series W60, W110 and W200 for the X-ray irradiations were chosen, determining their quality by the HVL method. Prior to the intercomparison, these beams were checked by the Physikalish Technische Bundesanstalt (PTB) using thermoluminescence dosimeters 'pill box', which were irradiated in air and in ICRU phantom. As result of this check, only one 'X ray beam got a deviation of 7%, while the rest of them were less than 3%. Periodic checks of the beams by a Primary Standard Dosimetry Laboratory such as PTB give reliability to the irradiations performed by this CRRD. (author) [es

  8. Information resources in state regulatory agencies-a California perspective

    Energy Technology Data Exchange (ETDEWEB)

    DiZio, S.M. [California Environmental Protection Agency, Sacramento (United States)

    1990-12-31

    Various state regulatory agencies have expressed a need for networking with information gatherers/researchers to produce a concise compilation of primary information so that the basis for regulatory standards can be scientifically referenced. California has instituted several programs to retrieve primary information, generate primary information through research, and generate unique regulatory standards by integrating the primary literature and the products of research. This paper describes these programs.

  9. Results of the ninth exercise of intercomparison in services of personal dosimetry in Argentina Republic in the year of 2011

    International Nuclear Information System (INIS)

    Ferrufino, G.A.; Discacciatti, P.A.; Lopez, F.O.

    2013-01-01

    In this paper we present the results of the ninth intercomparison exercise personal dosimetry services, conducted by the Nuclear Regulatory Authority in 2011. The exercise was designed to evaluate the performance of laboratories providing personal dosimetry services in Argentina , for X-rays and gamma radiation fields . This exercise was organized by the Nuclear Regulatory Authority with the Ministry of Health of the Nation and the Regional Reference Laboratory Centre for Dosimetry of the National Atomic Energy Commission . The irradiations were carried out in full accordance with ISO 4037-3 . Participates all private companies in Argentina serving all personal dosimetry laboratories and agencies, provincial and national. Furthermore, the Laboratories from Cuba, Brazil and Uruguay also participate. The performance of a laboratory is considered acceptable if it meets the criteria established in the IRAM- ISO 14146 , which states: 'It is recognized that at most, one-tenth of dosimeters irradiated to exceed the limits'. Of all of the laboratories that participated , 68% reported their results within the acceptance criteria above. The primary objective of this intercomparison exercise is to provide an objective tool to evaluate the ability of personnel dosimetry services. (author)

  10. Report of a consultants meeting on dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Pernicka, F.

    1999-01-01

    During its biennial meeting in 1996, the Standing Advisory Committee 'SSDL Scientific Committee', recommended extending the long experience of the Agency in the field of standardization and monitoring dosimetry calibrations at radiotherapy and radiation protection level for the Secondary Standard Dosimetry Laboratory (SSDL) Network, to the field of diagnostic x-ray dosimetry. It was emphasized that 'Measurements on diagnostic x-ray machines have become increasingly important and some SSDLs are involved in such measurements. The Agency's dosimetry laboratory should, therefore, have proper radiation sources available to provide traceable calibrations to the SSDLs'. The purpose of the consultants' meeting was to advise the Agency on dosimetry in diagnostic radiology. They were specifically requested to overview scientific achievements in the field and to give advice to the Agency on the need for further developments. The purpose of the consultants' meeting was to advise the Agency on dosimetry in diagnostic radiology. They were specifically requested to overview scientific achievements in the field and to give advice to the Agency on the need for further developments

  11. Perofrmance testing of personnel dosimetry services. Final report of a two-year pilot study, October 1977-September 1979

    International Nuclear Information System (INIS)

    Plato, P.; Hudson, G.

    1980-01-01

    A two-year pilot study was conducted of the Health Physics Society Standards Committee (HPSSC) Standard titled, Criteria for Testing Personnel Dosimetry Performance. The objectives of the pilot study were: to give processors an opportunity to correct any problems that are uncovered; to develop operational and administrative prodedures to be used later by a permanent testing laboratory; and to determine whether the proposed HPSSC Standard provides an adequate and practical test of dosimetry performance. Fifty-nine dosimetry processors volunteered to submit dosimeters for test irradiations according to the requirements of the HPSSC Standard. The feasibility of using the HPSSC Standard for a future mandatory testing program for personnel dosimetry processors is discussed. This report shows the results of the pilot study and contains recommendations for revisions in the Standard that will make a mandatory testing program useful to regulatory agencies, dosimetry processors, and radiation workers that use personnel dosimeters

  12. Decisions by regulatory agencies: are they evidence-based?

    Directory of Open Access Journals (Sweden)

    Furberg Curt D

    2007-04-01

    Full Text Available Abstract Contradictory statements about the non-steroidal anti-inflammatory drugs from the European Medicines Agency and the United States Food and Drug Administration have raised questions about whether regulatory decisions are evidence-based. For the selective COX-2 inhibitors, there are clear contraindications and warnings in Europe, but only a vaguely worded Black Box warning in the United States. All the non-selective agents are given an almost "clean bill of health" in Europe, while all of them are judged to have a similar risk-benefit ratio as celecoxib in the United States. The regulatory agencies have failed to recognize the clinical trial evidence that the risk of cardiovascular events varies substantially among the non-selective agents, with diclofenac carrying the highest risk of harm.

  13. International cooperative effort to establish dosimetry standardization for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV.

    1989-01-01

    Radiation processing is a rapidly developing technology with numerous applications in food treatment, sterilization, and polymer modification. The effectiveness of the process depends, however, on the proper application of dose and its measurement. These aspects are being considered by a wide group of experts from around the world who have joined together to write a comprehensive set of standards for dosimetry for radiation processing. Originally formed in 1984 to develop standards for food processing dosimetry, the group has now expanded into a full subcommittee of the American Society for Testing and Materials (ASTM), with 97 members from 19 countries. The scope of the standards now includes dosimetry for all forms of radiation processing. The group has now completed and published four standards, and is working on an additional seven. Three are specifically for food applications and the others are for all radiation applications, including food processing. Together, this set of standards will specify acceptable guidelines and methods for accomplishing the required irradiation treatment, and will be available for adoption by national regulatory agencies in their procedures and protocols. 1 tab

  14. Survey of extreme load design regulatory agency licensing requirements for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Stevenson, J D

    1976-04-01

    Since 1965, when extreme load requirements began to be considered explicitly in nuclear power plant design, there has been a gradual divergence in requirements imposed by national regulatory agencies. However, nuclear plant safety is an international problem because of the potential international effects of any postulated plant failure. For this reason this paper has been prepared in an attempt to highlight the differences in national criteria currently used in the extreme load design of nuclear plant facilities. No attempt has been made to evaluate the relative merit of the criteria established by the various national regulatory agencies. This paper presents the results of a recent survey made of national atomic energy regulatory agencies and major nuclear steam supply design agencies, which requested a summary of current licensing criteria associated with earthquake, extreme wind (tornado), flood, airplane crash and accident (pipe break) loads applicable within the various national jurisdictions. Also presented are a number of comparisons which are meant to illustrate the differences in national regulatory criteria.

  15. Survey of extreme load design regulatory agency licensing requirements for nuclear power plants

    International Nuclear Information System (INIS)

    Stevenson, J.D.

    1976-01-01

    Since 1965, when extreme load requirements began to be considered explicitly in nuclear power plant design, there has been a gradual divergence in requirements imposed by national regulatory agencies. However, nuclear plant safety is an international problem because of the potential international effects of any postulated plant failure. For this reason this paper has been prepared in an attempt to highlight the differences in national criteria currently used in the extreme load design of nuclear plant facilities. No attempt has been made to evaluate the relative merit of the criteria established by the various national regulatory agencies. This paper presents the results of a recent survey made of national atomic energy regulatory agencies and major nuclear steam supply design agencies, which requested a summary of current licensing criteria associated with earthquake, extreme wind (tornado), flood, airplane crash and accident (pipe break) loads applicable within the various national jurisdictions. Also presented are a number of comparisons which are meant to illustrate the differences in national regulatory criteria. (Auth.)

  16. 75 FR 54917 - Criteria for Nominating Materials Licensees for the U.S. Nuclear Regulatory Commission's Agency...

    Science.gov (United States)

    2010-09-09

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0294] Criteria for Nominating Materials Licensees for the U.S. Nuclear Regulatory Commission's Agency Action Review Meeting AGENCY: Nuclear Regulatory Commission. ACTION: Request for comment. SUMMARY: It is the policy of the U.S. Nuclear Regulatory Commission...

  17. Bioremediation, regulatory agencies and public acceptance of this technology

    International Nuclear Information System (INIS)

    Westlake, D. W. S.

    1997-01-01

    The technology of bioremediation, i.e. the utilization of microorganisms to degrade environmental pollutants, the dangers and consequences inherent in the large-scale use of microbial organisms in such processes, and the role of regulatory agencies in the utilization and exploitation of bioremediation technologies, were discussed. Factors influencing public acceptance of bioremediation as a satisfactory tool for cleaning up the environment vis-a-vis other existing and potential rehabilitation techniques were also reviewed. The ambiguity of regulatory agencies in the matter of bioremediation was noted. For example, there are many regulatory hurdles relative to the testing, use and approval of transgenic microorganisms for use in bioremediation. On the other hand, the use and release of engineered plants is considered merely another form of hybrid and their endorsement is proceeding rapidly. With regard to public acceptance, the author considered bioremediation technology as too recent, with not enough successful applications to attract public attention. Although the evidence suggests that bioremediation is environmentally safe, the efficacy, reliability and predictability of the various technologies have yet to be demonstrated. 25 refs

  18. High-dosage dosimetry programme of the IAEA

    International Nuclear Information System (INIS)

    Mehta, K.

    1999-01-01

    The high-dose dosimetry programme was initiated by the International Atomic Energy Agency in 1977. Like any other Agency programme, this one has various activities. These cover: research contracts and research agreements, co-ordinated research projects (CRP), training courses, and laboratory-based activities. The Agency's dose quality audit service (International Dose Assurance Service, IDAS), initiated in 1985, is one of the key elements of the programme. At earlier times, the technical part was operated through a laboratory in Germany. However, after purchasing the Bruker ESR spectrometer, the entire service has been operated from the Agency since 1992. This audit service has served well the needs of various institutes around the world involved with radiation processing. We have had two Co-ordinated Research Projects (the second one is in its last year) over the last several years. Both were/are aimed at standardization of dosimetry for radiation processing. Nine or ten participants of each CRP were about evenly distributed between the developed and developing Member States. In collaboration with the Food and Environmental Protection Section and the Industrial Applications and Chemistry Section, the Dosimetry and Medical Radiation Physics Section has participated in several training courses; these have been mainly regional courses. This collaboration has worked well since such courses combine specific radiation processing applications with the needs of good dosimetry and process control. Also, the Agency has organised several dose intercomparisons in recent time. The activities of the high-dose dosimetry programme since the last symposium (November 1990) are reviewed here. (author)

  19. International cooperative effort to establish dosimetry standardization for radiation processing

    International Nuclear Information System (INIS)

    Farrar, Harry IV

    1990-01-01

    Radiation processing is a rapidly developing technology with numerous applications in food treatment, sterilization, and polymer modification. The effectiveness of the process depends, however, on the proper application of dose and its measurement. These aspects are being considered by a wide group of experts from around the world who have joined together to write a comprehensive set of standards for dosimetry for radiation processing. Originally formed in 1984 to develop standards for food processing dosimetry, the group has now expanded into a full subcommittee of the American Society for Testing and Materials (ASTM), with 97 members from 19 countries. The scope of the standards now includes dosimetry for all forms and applications of radiation processing. To date, the group has completed and published four standards, and is working on an additional seven. Three are specifically for food applications and the others are for all radiation applications, including food processing. Together, this set of standards will specify acceptable guidelines and methods for accomplishing the required irradiation treatment. This set will be available for adoption by national regulatory agencies or other standards-setting organizations for their procedures and protocols. (author)

  20. Strategy for communicating benefit-risk decisions: a comparison of regulatory agencies' publicly available documents.

    Science.gov (United States)

    Leong Wai Yeen, James; Salek, Sam; Walker, Stuart

    2014-01-01

    The assessment report formats of four major regulatory reference agencies, US Food and Drug Administration, European Medicines Agency, Health Canada, and Australia's Therapeutic Goods Administration were compared to a benefit-risk (BR) documentation template developed by the Centre for Innovation in Regulatory Science and a four-member Consortium on Benefit-Risk Assessment. A case study was also conducted using a US FDA Medical Review, the European Public Assessment Report and Australia's Public Assessment Report for the same product. Compared with the BR Template, existing regulatory report formats are inadequate regarding the listing of benefits and risks, the assigning of relative importance and values, visualization and the utilization of a detailed, systematic, standardized structure. The BR Template is based on the principles of BR assessment common to major regulatory agencies. Given that there are minimal differences among the existing regulatory report formats, it is timely to consider the feasibility of a universal template.

  1. Court-agency interaction in environmental policymaking: the cases of the Nuclear Regulatory Commission and the Environmental Protection Agency

    International Nuclear Information System (INIS)

    Thomas, L.W.

    1981-01-01

    This study examines the increasingly active participation of courts in the administrative process as well as agency responses to court-imposed policy shifts. More specifically, it is an investigation of the interaction between the federal courts, primarily the Supreme Court and the District of Columbia Court of Appeals, and two federal regulatory agencies, the Nuclar Regulatory Commission and the Environmental Protection Agency. There are five objectives to the study. The first is to examine the natura of court-agency interaction and to determine the extent to which patterns of judicial review of administrative actions can be discerned. The second is to examine the effect of court orders on agency programs and policies. The third is to assess the anticipatory dimension of court-agency relations. The fourth is to inquire into the recurring dimension of court-agency interaction and to determine its effect on subsequent court decisions. The last is to assess the institutional capacity of courts to deal with scientific and technological issues. This study indicates that judicial review has a substantial effect on the NRC's and the EPA's decision-making activities. Few, if any, recent major policy decisions of the two agencies have not been scrutinized closely by federal appellate courts. During the past decade, the courts have blocked policy initiative on numerous occasions and have been the primary source of change in others. In addition, the mere anticipation of judicial review was found to be a factor motivating the two agencies to make reasoned decisions

  2. Safety Culture Implementation in Indonesian Nuclear Energy Regulatory Agency (BAPETEN)

    International Nuclear Information System (INIS)

    Nurwidi Astuti, Y.H.; Dewanto, P.

    2016-01-01

    The Indonesia Nuclear Energy Act no. 10 of 1997 clearly stated that Nuclear Energy Regulatory Agency (BAPETEN) is the Nuclear Regulatory Body. This is the legal basis of BAPETEN to perform regulatory functions on the use of nuclear energy in Indonesia, including regulation, authorisation, inspection and enforcement. The Independent regulatory functions are stipulated in Article 4 and Article 14 of the Nuclear Energy Act no. 10 (1997) which require the government to establish regulatory body that is reporting directly to the president and has responsibility to control of the use of nuclear energy. BAPETEN has been start fully its functioning on January 4, 1999. In it roles as a regulatory body, the main aspect that continues and always to be developed is the safety culture. One of the objectives of regulatory functions is “to increase legal awareness of nuclear energy of the user to develop safety culture” (Article 15, point d), while in the elucidation of article 15 it is stipulated that “safety culture is that of characteristics and attitudes in organizations and individual that emphasise the importance of safety”.

  3. 77 FR 12896 - Self-Regulatory Organizations; Midwest Clearing Corporation; Order Cancelling Clearing Agency...

    Science.gov (United States)

    2012-03-02

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-66458; File No. 600-9] Self-Regulatory Organizations; Midwest Clearing Corporation; Order Cancelling Clearing Agency Registration February 24, 2012. I... Act provides that in the event any self- regulatory organization is no longer in existence or has...

  4. Canadian space agency discipline working group for space dosimetry and radiation science

    International Nuclear Information System (INIS)

    Waker, Anthony; Waller, Edward; Lewis, Brent; Bennett, Leslie; Conroy, Thomas

    2008-01-01

    Full text: One of the great technical challenges in the human and robotic exploration of space is the deleterious effect of radiation on humans and physical systems. The magnitude of this challenge is broadly understood in terms of the sources of radiation, however, a great deal remains to be done in the development of instrumentation, suitable for the space environment, which can provide real-time monitoring of the complex radiation fields encountered in space and a quantitative measure of potential biological risk. In order to meet these research requirements collaboration is needed between experimental nuclear instrumentation scientists, theoretical scientists working on numerical modeling techniques and radiation biologists. Under the auspices of the Canadian Space Agency such a collaborative body has been established as one of a number of Discipline Working Groups. Members of the Space Dosimetry and Radiation Science working group form a collaborative network across Canada including universities, government laboratories and the industrial sector. Three central activities form the core of the Space Dosimetry and Radiation Science DWG. An instrument sub-group is engaged in the development of instruments capable of gamma ray, energetic charged particle and neutron dosimetry including the ability to provide dosimetric information in real-time. A second sub-group is focused on computer modeling of space radiation fields in order to assess the performance of conceptual designs of detectors and dosimeters or the impact of radiation on cellular and sub-cellular biological targets and a third sub-group is engaged in the study of the biological effects of space radiation and the potential of biomarkers as a method of assessing radiation impact on humans. Many working group members are active in more than one sub-group facilitating communication throughout the whole network. A summary progress-report will be given of the activities of the Discipline Working Group and the

  5. Interest of numerical dosimetry in radiation protection: mean of substitution or measurements consolidation?; Interet de la dosimetrie numerique en radioprotection: moyen de substitution ou de consolidation des mesures?

    Energy Technology Data Exchange (ETDEWEB)

    Lahaye, T.; Chau, Q. [Institut de Radioprotection et de Surete Nucleaire (IRSN/DPHD/SDOS), Service Dosimetrie, 92 - Fontenay-aux-Roses (France); Ferragut, A.; Gillot, J.Y. [SAPHYMO, 91 - Massy (France)

    2003-07-01

    The use of calculation codes allows to reduce the costs and the time limits. These codes brings to operators elements to reinforce their projected dosimetry. In the cases of accidental overexposure, the numerical dosimetry comes in complement of clinical and biological investigations to give an estimation as precise as possible of the received dose. For particular situations where it does not exist an adapted instrumentation, the numerical dosimetry can substitute to conventional techniques used by regulatory dosimetry (project for aviation personnel). (N.C.)

  6. Guide for dosimetry in radiation research on food and agricultural products

    International Nuclear Information System (INIS)

    2002-01-01

    This guide covers the minimum requirements for dosimetry and absorbed-dose validation needed to conduct research on the irradiation of food and agricultural products. Such research includes establishment of the quantitative relationship between the absorbed dose and the relevant effects in these products. This guide also describes the overall need for dosimetry in such research, and in reporting of the results. This guide is intended for use by research scientists in the food and agricultural communities, and not just scientists conducting irradiation research. It, therefore, includes more tutorial information than most other ASTM and ISO/ASTM dosimetry standards for radiation processing. This guide is in no way intended to limit the flexibility of the experimenter in the experimental design. However, the radiation source and experimental set up should be chosen such that the results of the experiment will be beneficial and understandable to other scientists, regulatory agencies, and the food and agricultural communities. The effects produced by ionizing radiation in biological systems depend on a large number of factors which may be physical, physiological, or chemical. Although not treated in detail in this guide, quantitative data of environmental factors that may affect the absorbed-dose response of dosimeters, such as temperature and moisture content in the food or agricultural products should be reported. The overall uncertainty in the absorbed-dose measurement and the inherent absorbed-dose range within the specimen should be taken into account in the design of an experiment. The guide covers research conducted using the following types of ionizing radiation: gamma rays, bremsstrahlung X-rays, and electron beams. This guide does not include other aspects of radiation processing research, such as planning of the experimental design. Dosimetry must be considered as an integral part of the experimental design. The guide does not include dosimetry for irradiator

  7. 77 FR 12898 - Self-Regulatory Organizations; Midwest Securities Trust Company; Order Cancelling Clearing Agency...

    Science.gov (United States)

    2012-03-02

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-66461; File No. 600-7] Self-Regulatory Organizations; Midwest Securities Trust Company; Order Cancelling Clearing Agency Registration February 24, 2012... the event any self-regulatory organization is no longer in existence or has ceased to do business in...

  8. Independent regulatory agencies and rules harmonization for the electricity sector and renewables in the Mediterranean region

    International Nuclear Information System (INIS)

    Cambini, Carlo; Franzi, Donata

    2013-01-01

    The paper analyses the existing regulatory framework for the electricity and renewables sectors, and the role of regulatory agencies in Northern Africa and Middle East countries, under the promotion by the European Union. Using data collected through an original survey directed at regulators, ministry departments and energy companies of the southern Mediterranean, the study is aimed at assessing the extent of agencies' independence looking at three main dimensions of independence: regulatory instruments available to regulators and decision making autonomy; regulators' organizational autonomy; and regulators accountability. Results show that those countries having established an independent regulator have a more credible regulatory framework than those countries in which such a body does not exist. In particular, the analysis shows that Turkey, Croatia and Jordan have defined a regulatory framework that limits administrative expropriation and, consequently, creates an environment more suitable for attracting investments in the electricity and renewables sector. On the institutional ground, this is probably related with the harmonization of regulatory standards promoted by the European Union through the neighboring policy, for the Jordan case, and the membership perspective, in the Turkish and Croatian cases. - Highlights: • We analyze the existing regulatory framework in Northern Africa and Middle East countries. • We construct an original dataset through a survey directed to national regulators. • The extent of agencies' independence has been assessed in different dimensions. • These dimensions are decision making autonomy; organizational autonomy; and accountability. • Few countries have defined a regulatory framework limiting administrative expropriation

  9. Results of the ninth exercise of intercomparison in services of personal dosimetry in Argentina Republic in the year of 2011; Resultados del noveno ejercicio de intercomparacion de servicios de dosimetria personal realizado en la Republica Argentina en el ano 2011

    Energy Technology Data Exchange (ETDEWEB)

    Ferrufino, G.A.; Discacciatti, P.A.; Lopez, F.O., E-mail: gferrufino@am.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aies (Argentina)

    2013-10-01

    In this paper we present the results of the ninth intercomparison exercise personal dosimetry services, conducted by the Nuclear Regulatory Authority in 2011. The exercise was designed to evaluate the performance of laboratories providing personal dosimetry services in Argentina , for X-rays and gamma radiation fields . This exercise was organized by the Nuclear Regulatory Authority with the Ministry of Health of the Nation and the Regional Reference Laboratory Centre for Dosimetry of the National Atomic Energy Commission . The irradiations were carried out in full accordance with ISO 4037-3 . Participates all private companies in Argentina serving all personal dosimetry laboratories and agencies, provincial and national. Furthermore, the Laboratories from Cuba, Brazil and Uruguay also participate. The performance of a laboratory is considered acceptable if it meets the criteria established in the IRAM- ISO 14146 , which states: 'It is recognized that at most, one-tenth of dosimeters irradiated to exceed the limits'. Of all of the laboratories that participated , 68% reported their results within the acceptance criteria above. The primary objective of this intercomparison exercise is to provide an objective tool to evaluate the ability of personnel dosimetry services. (author)

  10. Regulatory activities

    International Nuclear Information System (INIS)

    2001-01-01

    This publication, compiled in 8 chapters, presents the regulatory system developed by the Nuclear Regulatory Authority (NRA) of the Argentine Republic. The following activities and developed topics in this document describe: the evolution of the nuclear regulatory activity in Argentina; the Argentine regulatory system; the nuclear regulatory laws and standards; the inspection and safeguards of nuclear facilities; the emergency systems; the environmental systems; the environmental monitoring; the analysis laboratories on physical and biological dosimetry, prenatal irradiation, internal irradiation, radiation measurements, detection techniques on nuclear testing, medical program on radiation protection; the institutional relations with national and international organization; the training courses and meeting; the technical information

  11. The Australian radiation protection and nuclear safety agency megavoltage photon thermoluminescence dosimetry postal audit service 2007–2010

    International Nuclear Information System (INIS)

    Oliver, C.P.; Butler, D.J.; Webb, D.V.

    2012-01-01

    The Australian radiation protection and nuclear safety agency (ARPANSA) has continuously provided a level 1 mailed thermoluminescence dosimetry audit service for megavoltage photons since 2007. The purpose of the audit is to provide an independent verification of the reference dose output of a radiotherapy linear accelerator in a clinical environment. Photon beam quality measurements can also be made as part of the audit in addition to the output measurements. The results of all audits performed between 2007 and 2010 are presented. The average of all reference beam output measurements calculated as a clinically stated dose divided by an ARPANSA measured dose is 0.9993. The results of all beam quality measurements calculated as a clinically stated quality divided by an ARPANSA measured quality is 1.0087. Since 2011 the provision of all auditing services has been transferred from the Ionizing Radiation Standards section to the Australian Clinical Dosimetry Service (ACDS) which is currently housed within ARPANSA.

  12. Interest of numerical dosimetry in radiation protection: mean of substitution or measurements consolidation?

    International Nuclear Information System (INIS)

    Lahaye, T.; Chau, Q.; Ferragut, A.; Gillot, J.Y.

    2003-01-01

    The use of calculation codes allows to reduce the costs and the time limits. These codes brings to operators elements to reinforce their projected dosimetry. In the cases of accidental overexposure, the numerical dosimetry comes in complement of clinical and biological investigations to give an estimation as precise as possible of the received dose. For particular situations where it does not exist an adapted instrumentation, the numerical dosimetry can substitute to conventional techniques used by regulatory dosimetry (project for aviation personnel). (N.C.)

  13. Driven by Expertise and Insulation? The Autonomy of European Regulatory Agencies

    Directory of Open Access Journals (Sweden)

    Christoph Ossege

    2015-03-01

    Full Text Available Expertise and autonomy are cornerstones to the effective operation and legitimacy of European Regulatory Agencies (ERAs. Yet, we know little about ERAs’ actual autonomy, nor about factors shaping it. This article studies ERAs’ actual autonomy from public and private actors, emphasising two crucial explanatory factors: expertise and rulemaking competences. The lack of insights on expertise is particularly striking, as expertise—the “raison d’être” and main resource of expert bodies—provides ERAs with a potentially powerful means to increase autonomy. Relying on a rational institutionalist framework within which ERAs enjoy substantive discretion to pursue their goals, the study empirically compares three powerful ERAs—the European Medicines Agency, the European Chemicals Agency, and the European Food Safety Authority. Based on the analysis of 39 semi-structured expert interviews, findings show that expertise is a crucial explanation for ERAs’ substantive autonomy from the Commission. Towards research intensive private stakeholders, the role of expertise becomes less pronounced. Instead, ERAs are more successful in protecting their autonomy by engaging in the risk-averse interpretation of the regulatory framework and by adapting rules over time to adapt their needs: they engage in “procedural insulation”. Political salience provides a scope condition for ERAs to use expert knowledge and rulemaking competences more strategically—potentially undermining scientific quality.

  14. RCT: Module 2.04, Dosimetry, Course 8769

    Energy Technology Data Exchange (ETDEWEB)

    Hillmer, Kurt T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-11

    This course will introduce the types of instruments used to measure external and internal radiation to people. Dosimetry is the quantitative assessment of radiation received by the human body. Several types of dosimeters are used worldwide. This information is valuable to all radiological control personnel because dosimeters are the only direct method to measure and document personnel radiation exposure and ensure regulatory compliance with applicable limits. This course will cover dosimetry terms, Department of Energy (DOE) limits, Los Alamos National Laboratory (LANL) administrative guidelines, thermoluminescent dosimeters (TLDs), LANL dosimetry, and bioassay assessment methods. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and providing in-thefield skills.

  15. Politically Induced Regulatory Risk and Independent Regulatory Agencies

    OpenAIRE

    Strausz, Roland

    2015-01-01

    Uncertainty in election outcomes generates politically induced regulatory risk. Political parties' risk attitudes towards such risk depend on a fluctuation effect that hurts both parties and an output--expansion effect that benefits at least one party. Notwithstanding the parties' risk attitudes, political parties have incentives to negotiate away all regulatory risk by pre-electoral bargaining. Efficient pre-electoral bargaining outcomes fully eliminate politically induced regulatory risk. P...

  16. Guideline for regulatory agencies in evaluating contents of root cause analysis by operators

    International Nuclear Information System (INIS)

    Hata, Takaya; Makino, Maomi; Kosaka, Atsuhiko

    2008-01-01

    'Guideline for Regulatory Agencies in Evaluating Contents of Root cause Analysis by Operators' was enacted as the policy for new inspection system in Japan. The objective is to indicate the view point to verify the appropriateness of the corrective actions and preventive actions implemented by operators based on root cause analysis and its analysis results. This guideline is leading to take four points into special consideration for adequate application. They are encouragement of further activities of the operators, flexible interpretation of the intention, versatility of the analysis methods and concepts and consideration of no blame culture. Moreover, as view point for regulatory agencies, it indicates with special emphasis that neutrality of the analyzing party, objectivity of analysis result, and logicality of the analysis method are ensured. This guideline shall be continuously reviewed through integration of lessons learned from active use in future. (author)

  17. Neutron personnel dosimetry considerations for fusion reactors

    International Nuclear Information System (INIS)

    Barton, T.P.; Easterly, C.E.

    1979-07-01

    The increasing development of fusion reactor technology warrants an evaluation of personnel neutron dosimetry systems to aid in the concurrent development of a radiation protection program. For this reason, current state of knowledge neutron dosimeters have been reviewed with emphasis placed on practical utilization and the problems inherent in each type of dosimetry system. Evaluations of salient parameters such as energy response, latent image instability, and minimum detectable dose equivalent are presented for nuclear emulsion films, track etch techniques, albedo and other thermoluminescent dosimetry techniques, electrical conductivity damage effects, lyoluminescence, thermocurrent, and thermally stimulated exoelectron emission. Brief summaries of dosimetry regulatory requirements and intercomparison study results help to establish compliance and recent trends, respectively. Spectrum modeling data generated by the Neutron Physics Division of Oak Ridge National Laboratory for the Princeton Tokamak Fusion Test Reactor (TFTR) Facility have been analyzed by both International Commission on Radiological Protection fluence to dose conversion factors and an adjoint technique of radiation dosimetry, in an attempt to determine the applicability of current neutron dosimetry systems to deuterium and tritium fusion reactor leakage spectra. Based on the modeling data, a wide range of neutron energies will probably be present in the leakage spectra of the TFTR facility, and no appreciable risk of somatic injury to occupationally exposed workers is expected. The relative dose contributions due to high energy and thermal neutrons indicate that neutron dosimetry will probably not be a serious limitation in the development of fusion power

  18. Third conference on radiation protection and dosimetry

    International Nuclear Information System (INIS)

    1991-01-01

    This conference has been designed with the objectives of promoting communication among applied, research, regulatory, and standards personnel involved in radiation protection and providing them with sufficient information to evaluate their programs. To partly fulfill these objectives, a technical program consisting of more than 75 invited and contributed oral presentations encompassing all aspects of radiation protection has been prepared. General topics include external dosimetry, internal dosimetry, instruments, regulations and standards, accreditation and test programs, research advances, and applied program experience. This publication provides a summary of the technical program and a collection of abstracts of the oral presentations

  19. Dosimetry; La dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  20. The Environmental Protection Agency in the Early Trump Administration: Prelude to Regulatory Capture.

    Science.gov (United States)

    Dillon, Lindsey; Sellers, Christopher; Underhill, Vivian; Shapiro, Nicholas; Ohayon, Jennifer Liss; Sullivan, Marianne; Brown, Phil; Harrison, Jill; Wylie, Sara

    2018-04-01

    We explore and contextualize changes at the Environmental Protection Agency (EPA) over the first 6 months of the Trump administration, arguing that its pro-business direction is enabling a form of regulatory capture. We draw on news articles, public documents, and a rapid response, multisited interview study of current and retired EPA employees to (1) document changes associated with the new administration, (2) contextualize and compare the current pro-business makeover with previous ones, and (3) publicly convey findings in a timely manner. The lengthy, combined experience of interviewees with previous Republican and Democratic administrations made them valuable analysts for assessing recent shifts at the Scott Pruitt-led EPA and the extent to which these shifts steer the EPA away from its stated mission to "protect human and environmental health." Considering the extent of its pro-business leanings in the absence of mitigating power from the legislative branch, we conclude that its regulatory capture has become likely-more so than at similar moments in the agency's 47-year history. The public and environmental health consequences of regulatory capture of the EPA will probably be severe and far-reaching.

  1. Design of an internal dosimetry program

    International Nuclear Information System (INIS)

    Wu, C.F.; Goff, T.E.

    2004-01-01

    Measurement of radiation dose is an essential element of radiation protection programs at nuclear facilities. To protect workers and demonstrate compliance with regulatory requirements, dosimetry programs must be established based on sound technical basis. Historically, external exposure was controlled by occupational dose limits. Internal exposure to radionuclides was limited by maximum permissible body burden and maximum permissible concentration. With the issuance of ICRP 26, ICRP 30, DOE Order 5480.11, DOE/EH-0256T, and the new 10 CFR 20, it has become a requirement that internal dose be assessed and the sum of internal and external doses be maintained below regulatory limits. Nuclear facilities are required to have internal dose evaluation programs adequate to demonstrate compliance with radiation protection standards (RPSs). The Waste Isolation Pilot Plant is a DOE facility designed to demonstrate safe disposal of transuranic (TRU) wastes in an ancient salt bed 2,150 feet underground. Internal dose measurement is required to support waste handling activities. This paper describes the technical basis for the WIPP Internal Dosimetry Program. (author)

  2. Regulatory activities; Actividades regulatorias

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This publication, compiled in 8 chapters, presents the regulatory system developed by the Nuclear Regulatory Authority (NRA) of the Argentine Republic. The following activities and developed topics in this document describe: the evolution of the nuclear regulatory activity in Argentina; the Argentine regulatory system; the nuclear regulatory laws and standards; the inspection and safeguards of nuclear facilities; the emergency systems; the environmental systems; the environmental monitoring; the analysis laboratories on physical and biological dosimetry, prenatal irradiation, internal irradiation, radiation measurements, detection techniques on nuclear testing, medical program on radiation protection; the institutional relations with national and international organization; the training courses and meeting; the technical information.

  3. The International Reactor Dosimetry File (IRDF-85)

    International Nuclear Information System (INIS)

    Cullen, D.E.; McLaughlin, P.K.

    1985-04-01

    This document describes the contents of the second version of the International Reactor Dosimetry File (IRDF-85), distributed by the Nuclear Data Section of the International Atomic Energy Agency. This library superseded IRDF-82. (author)

  4. Arrangement between the International Atomic Energy Agency and the World Health Organization concerning the establishment and operation of a network of Secondary Standard Dosimetry Laboratories

    International Nuclear Information System (INIS)

    1986-01-01

    The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO), recognizing that they have been co-operating in the operation of a network of Secondary Standard Dosimetry Laboratories (the Network), established pursuant to a Working Arrangement, dated 5 April 1976; and desiring to continue this co-operation in accordance with Article V of the relationship agreement concluded by IAEA and WHO in 1959; hereby enter a new arrangement to guide their work in operating the Network and providing assistance, when needed, to individual Secondary Standard Dosimetry Laboratories (SSDLs). The purpose of this Arrangement is to set forth responsibilities of IAEA and WHO in the operation and support of the Network and to establish criteria for SSDLs

  5. Proceedings of the third conference on radiation protection and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Swaja, R.E.; Sims, C.S.; Casson, W.H. [eds.

    1991-10-01

    The Third Conference on Radiation Protection and Dosimetry was held during October 21--24, 1991, at the Sheraton Plaza Hotel in Orlando, Florida. This meeting was designed with the objectives of promoting communication among applied, research, regulatory, and standards personnel involved in radiation protection, and providing them with sufficient information to evaluate their programs. To meet these objectives, a technical program consisting of more than 75 invited and contributed oral presentations encompassing all aspects of radiation protection was prepared. General topics considered in the technical session included external dosimetry, internal dosimetry, instruments, accident dosimetry, regulations and standards, research advances, and applied program experience. In addition, special sessions were held to afford attendees the opportunity to make short presentations of recent work or to discuss topics of general interest. Individual reports are processed separately on the database.

  6. Proceedings of the third conference on radiation protection and dosimetry

    International Nuclear Information System (INIS)

    Swaja, R.E.; Sims, C.S.; Casson, W.H.

    1991-10-01

    The Third Conference on Radiation Protection and Dosimetry was held during October 21--24, 1991, at the Sheraton Plaza Hotel in Orlando, Florida. This meeting was designed with the objectives of promoting communication among applied, research, regulatory, and standards personnel involved in radiation protection, and providing them with sufficient information to evaluate their programs. To meet these objectives, a technical program consisting of more than 75 invited and contributed oral presentations encompassing all aspects of radiation protection was prepared. General topics considered in the technical session included external dosimetry, internal dosimetry, instruments, accident dosimetry, regulations and standards, research advances, and applied program experience. In addition, special sessions were held to afford attendees the opportunity to make short presentations of recent work or to discuss topics of general interest. Individual reports are processed separately on the database

  7. Technical basis for external dosimetry at the Waste Isolation Pilot Plant (WIPP)

    International Nuclear Information System (INIS)

    Bradley, E.W.; Wu, C.F.; Goff, T.E.

    1993-01-01

    The WIPP External Dosimetry Program, administered by Westinghouse Electric Corporation, Waste Isolation Division, for the US Department of Energy (DOE), provides external dosimetry support services for operations at the Waste Isolation Pilot Plant (WIPP) Site. These operations include the receipt, experimentation with, storage, and disposal of transuranic (TRU) wastes. This document describes the technical basis for the WIPP External Radiation Dosimetry Program. The purposes of this document are to: (1) provide assurance that the WIPP External Radiation Dosimetry Program is in compliance with all regulatory requirements, (2) provide assurance that the WIPP External Radiation Dosimetry Program is derived from a sound technical base, (3) serve as a technical reference for radiation protection personnel, and (4) aid in identifying and planning for future needs. The external radiation exposure fields are those that are documented in the WIPP Final Safety Analysis Report

  8. Driven by expertise and insulation?: the autonomy of European regulatory agencies

    OpenAIRE

    Ossege, Christoph

    2015-01-01

    Expertise and autonomy are cornerstones to the effective operation and legitimacy of European Regulatory Agencies (ERAs). Yet, we know little about ERAs' actual autonomy, nor about factors shaping it. This article studies ERAs' actual autonomy from public and private actors, emphasising two crucial explanatory factors: expertise and rulemaking competences. The lack of insights on expertise is particularly striking, as expertise -the "raison d'être" and main resource of expert bodies- provides...

  9. Review of the correlation between results of cytogenetic dosimetry from blood lymphocytes and EPR dosimetry from tooth enamel for victims of radiation accidents

    International Nuclear Information System (INIS)

    Khvostunov, I.K.; Ivannikov, A.I.; Skvortsov, V.G.; Golub, E.V.; Nugis, V. Yu.

    2015-01-01

    The goal of this study was to compare dose estimates from electron paramagnetic resonance (EPR) dosimetry with teeth and cytogenetic dosimetry with blood lymphocytes for 30 victims of radiation accidents. The whole-body exposures estimated by tooth enamel EPR dosimetry were ranging from 0.01 to 9.3 Gy. Study group comprised victims exposed to acute and prolonged irradiation at high and low dose rate in different accidents. Blood samples were taken from each of them for cytogenetic analysis. Aberrations were scored and analysed according to International Atomic Energy Agency (IAEA) guidelines for conventional and FISH analysis. Tooth samples were collected in dental clinics after they had been extracted during ordinary practice. EPR dosimetry was performed according to the IAEA protocol. EPR dosimetry showed good correlation with dosimetry based on chromosomal analysis. All estimations of cytogenetic dose below detection limit coincide with EPR dose estimates within the ranges of uncertainty. The differences between cytogenetic and EPR assays may occur in a case of previous unaccounted exposure, non-homogeneous irradiation and due to contribution to absorbed dose from neutron irradiation. (authors)

  10. Dosimetry in Interventional Radiology - Effective Dose Estimation

    International Nuclear Information System (INIS)

    Miljanic, S.; Buls, N.; Clerinx, P.; Jarvinen, H.; Nikodemova, D.; Ranogajec-Komor, M; D'Errico, F.

    2008-01-01

    Interventional radiological procedures can lead to significant radiation doses to patients and to staff members. In order to evaluate the personal doses with respect to the regulatory dose limits, doses measured by dosimeters have to be converted to effective doses (E). Measurement of personal dose equivalent Hp(10) using a single unshielded dosimeter above the lead apron can lead to significant overestimation of the effective dose, while the measurement with dosimeter under the apron can lead to underestimation. To improve the accuracy, measurements with two dosimeters, one above and the other under the apron have been suggested ( d ouble dosimetry ) . The ICRP has recommended that interventional radiology departments develop a policy that staff should wear two dosimeters. The aim of this study was to review the double dosimetry algorithms for the calculation of effective dose in high dose interventional radiology procedures. The results will be used to develop general guidelines for personal dosimetry in interventional radiology procedures. This work has been carried out by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its 6th Framework Program.(author)

  11. Standards in radiation protection at the IAEA Dosimetry Laboratory

    International Nuclear Information System (INIS)

    Czap, L.; Pernicka, F.; Matscheko, G.; Andreo, P.

    1999-01-01

    Approximately 90% of the Secondary Standard Dosimetry Laboratories (SSDLs) provide users with calibrations of radiation protection instruments, and the Agency is making every necessary effort to insure that SSDLs measurements in radiation protection are traceable to Primary Standards. The IAEA provides traceable calibrations of ionization chambers in terms of air kerma at radiation protection levels and ambient dose equivalent calibrations. SSDLs are encouraged to use the calibrations available from the Agency to provide traceability for their radiation protection measurements. Measurements on diagnostic X ray generators have become increasingly important in radiation protection and some SSDLs are involved in such measurements. The IAEA has proper radiation sources available to provide traceable calibrations to the SSDLs in this field, including an X ray unit specifically for mammography dedicated to standardization procedures. The different photon beam qualities and calibration procedures available in the Agency's Dosimetry Laboratory will be described. (author)

  12. Topics in radiation dosimetry radiation dosimetry

    CERN Document Server

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  13. Diagnostic radiology dosimetry: status and trends

    International Nuclear Information System (INIS)

    Rivera M, T.

    2015-10-01

    Full text: Medical radiation is by far the largest man-made source of public exposure to ionizing radiation. Since 1970 the expression of protection standards shifted from a dose- to a risk-based approach, with dose limits established to yield risks to radiation workers comparable with those for workers in other safe industries. Another hand, worldwide interest in patient dose measurement was stimulated by the publication of Patient Dose Reduction in Diagnostic Radiology by the UK National Radiological Protection Board (NRPB). In response to heightened awareness of the importance of patient dose contributed by radiology procedures, there has been a general trend to effect control of patient doses by applying the principles of optimization coupled with an increase in regulatory enforcement. In this sense, thermoluminescent dosimetry (TLD) has been actively proposed in the last 3 decades thanks to their successful applications in diagnostic radiology. At the same time, it is emerged as the best radiation dosimetry method. The present work presents advantages of thermoluminescent dosimetry for X-ray beams measurements and its optimization. (Author)

  14. Diagnostic radiology dosimetry: status and trends

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    Full text: Medical radiation is by far the largest man-made source of public exposure to ionizing radiation. Since 1970 the expression of protection standards shifted from a dose- to a risk-based approach, with dose limits established to yield risks to radiation workers comparable with those for workers in other safe industries. Another hand, worldwide interest in patient dose measurement was stimulated by the publication of Patient Dose Reduction in Diagnostic Radiology by the UK National Radiological Protection Board (NRPB). In response to heightened awareness of the importance of patient dose contributed by radiology procedures, there has been a general trend to effect control of patient doses by applying the principles of optimization coupled with an increase in regulatory enforcement. In this sense, thermoluminescent dosimetry (TLD) has been actively proposed in the last 3 decades thanks to their successful applications in diagnostic radiology. At the same time, it is emerged as the best radiation dosimetry method. The present work presents advantages of thermoluminescent dosimetry for X-ray beams measurements and its optimization. (Author)

  15. Organizational behavior of regulatory agencies: a case study of the Bureau of Consumer Services in the Pennsylvania Public Utility Commission

    Energy Technology Data Exchange (ETDEWEB)

    Silver, J.H.

    1981-01-01

    Regulatory agencies operate in a complex field of organizations and interest groups. The variety of behaviors that occur in the regulatory field are not satisfactorily explained by current interpretative frameworks. Regulatory agencies are at once criticized and praised. They flourish as organizational entities, yet they exhibit behavior that is often inexplicable. Notions like clientele capture, the politics of regulation, exchange theory, and institutionalized organizations do not singly explain the vagaries of regulatory behavior. A merger of these viewpoints, however, provides a foundation for a comprehensive interpretative framework. A bureau of consumer services within a state public utility commission is viewed as an institutionalized organization. From this perspective, a variety of ritual behaviors, based upon symbolic and tangible interorganizational exchanges are observed and characterized. The outcome of these exchanges is the establishment of the Bureau of Consumer Services as a legitimate regulatory agent with significant impact upon the formulation of regulatory policy in the formal proceedings of the Pennsylvania Public Utility Commission.

  16. US Department of Energy Laboratory Accredition Program (DOELAP) for personnel dosimetry systems

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, F.M.; Carlson, R.D.; Loesch, R.M.

    1993-12-31

    Accreditation of personnel dosimetry systems is required for laboratories that conduct personnel dosimetry for the U.S. Department of Energy (DOE). Accreditation is a two-step process which requires the participant to pass a proficiency test and an onsite assessment. The DOE Laboratory Accreditation Program (DOELAP) is a measurement quality assurance program for DOE laboratories. Currently, the DOELAP addresses only dosimetry systems used to assess the whole body dose to personnel. A pilot extremity DOELAP has been completed and routine testing is expected to begin in January 1994. It is expected that participation in the extremity program will be a regulatory requirement by January 1996.

  17. The Independence of the Media and Its Regulatory Agencies: Shedding new light on formal and actual independence against the national context

    NARCIS (Netherlands)

    Schultz, W.; Valcke, P.; Irion, K.

    2014-01-01

    Media independence is vital for democracies, and so is the independence of the regulatory bodies governing it. The Independence of the Media and its Regulatory Agencies explores the complex relationship between media governance and independence of media regulatory authorities within Europe, which

  18. Importance of dosimetry of irradiators for pre-clinical radiobiological experiments

    International Nuclear Information System (INIS)

    Vikram, Bhadrasain

    2014-01-01

    Importance of radiation dose in radiation biology has been increasingly recognized due to translational use of beyond 2Gy dose is in current practice. Hence, accurate dosimetry of biological irradiators is warranted. To address these problems and propose recommendations, the National Cancer Institute (NCI) along with the National Institute of Allergy and Infectious Diseases (NIAID) as well as the National Institute of Standards and Technology (NIST) highlighted a number of recommendations that will be presented in this talk that includes creating dosimetry standard operating procedures (SOPs) for both in-vitro as well as in-vivo experiments. Other recommendations include for journals (as well as to funding agencies) mandating the reporting of dosimetry of biological irradiators. (author)

  19. Quality control through dosimetry at a contract radiation processing facility

    International Nuclear Information System (INIS)

    Du Plessis, T.A.; Roediger, A.H.A.

    1985-01-01

    Reliable dosimetry procedures constitute a very important part of process control and quality assurance at a contract gamma radiation processing facility that caters for a large variety of different radiation applications. The choice, calibration and routine intercalibration of the dosimetry systems employed form the basis of a sound dosimetry policy in radiation processing. With the dosimetric procedures established, detailed dosimetric mapping of the irradiator upon commissioning (and whenever source modifications take place) is carried out to determine the radiation processing characteristics and peformance of the plant. Having established the irradiator parameters, routine dosimetry procedures, being part of the overall quality control measures, are employed. In addition to routine dosimetry, independent monitoring of routine dosimetry is performed on a bi-monthly basis and the results indicate a variation of better than 3%. On an annaul basis the dosimetry systems are intercalibrated through at least one primary standard dosimetry laboratory and to date a variation of better than 5% has been experienced. The company also participates in the Pilot Dose Assurance Service of the International Atomic Energy Agency, using the alanine/ESR dosimetry system. Routine calibration of the instrumentation employed is carried out on a regular basis. Detailed permanent records are compiled on all dosimetric and instrumentation calibrations, and the routine dosimetry employed at the plant. Certificates indicating the measured absorbed radiation doses are issued on request and in many cases are used for the dosimetric release of sterilized medical and pharmaceutical products. These procedures, used by Iso-Ster at its industrial gamma radiation facility, as well as the experience built up over a number of years using radiation dosimetry for process control and quality assurance are discussed. (author)

  20. The role of the IAEA Dosimetry Laboratory in the dissemination of standards for radiation protection

    International Nuclear Information System (INIS)

    Czap, L.; Andreo, P.; Matscheko, G.

    1998-01-01

    Approximately 90% of the Secondary Standard Dosimetry Laboratories (SSDLs) provide users with calibrations of radiation protection instruments, and the IAEA is taking every necessary effort to insure that SSDLs measurements are traceable to Primary Standards. The Agency has proper radiation sources available to provide traceable calibrations to the SSDLs involved in measurements on diagnostic x-ray generators, including an x-ray unit specifically for mammography dedicated to standardization procedures. The different photon beam qualities and calibration procedures available in the Agency's Dosimetry Laboratory are described

  1. Status report of the ESR/alanine project of the IAEA Dosimetry Laboratory

    International Nuclear Information System (INIS)

    Girzikowsky, R.

    1990-01-01

    The main tasks of the Dosimetry Laboratory of the IAEA are in the field of therapy-level dosimetry. Other dose ranges, i.e. protection-level standardization and calibration, are partly covered, too. On high-dose level the laboratory has been offering a Fricke-dosimetry service to Member States on request since 1965. In 1985 the Dosimetry Section has initiated an International Dose Assurance Service (IDAS). This service is an important part of the Agency's high-dose standardization programme and is based on Electron-Spin-Resonance (ESR) analysis of radiation-induced free radicals in alanine. This ESR/alanine dosimetry system was initially developed for high-dose application by GSF/Munich as the Agency's outside contractor. Although efforts were undertaken to equip the Agency Laboratory with an ESR analyzer since 1984, the purchase of an adequate unit was postponed until the end of 1988. From the date of establishment of the IDAS programme until today, the handling of all technical aspects, i.e. dosimeter production and evaluation was and is carried out by GSP/Munich under IAEA contract. As mentioned above, the IAEA Dosimetry Laboratory is in possession of its own ESR analyzer since December 1988. It was then installed in May 1989. Only one staff member of the laboratory was assigned to this project. He made himself acquainted with the analyzer, the measuring technique, and the application of alanine as dosimeter material. The ESR spectrometric analyzer is a CW ESR type ESP 300 manufactured by Bruker GmbH/FRG. It consists of a 9''/2,7 kW magnet, an X-band microwave bridge, a field regulator unit, a signal channel unit and a data system ESP 1620 based on the 68020 CPU. The probe material selected for measurement of concentration of radiation-induced free radicals is L-Alanine. This amino acid is a suitable material for transfer dosimeters due to its properties, i.e. wide sensitivity range (10 Gy to 100 kGy), energy independence for high-energy photons and electron

  2. Technical Memory 2008. Nuclear Regulatory Authority

    International Nuclear Information System (INIS)

    2011-01-01

    The technical memory 2008 of the Nuclear Regulatory Authority of Argentine Republic, compile the papers published in the subject on radiation protection and nuclear safety, and presented in journals, technical reports, congress or meetings of these specialties by personnel of the mentioned institution during 2008. In this edition the documents are presented on: environmental protection; transport of radioactive materials; regulations; research reactors and nuclear power plants; biological radiation effects; therapeutic uses of ionizing radiation and radioprotection of patients; internal dosimetry; physical dosimetry; knowledge management; radioactive waste management. [es

  3. Experiences and performance of the Harshaw dosimetry system at two major processing centres

    International Nuclear Information System (INIS)

    Tawil, R.A.; Olhalber, T.; Rathbone, B.

    1996-01-01

    The installations, operating practice, dose algorithms and results and maintenance experience at two major dosimetry processing centres are described. System selection considerations and a comprehensive quality programme are described in the light of the publication of testing requirements by various dosimetry regulatory organisations. Reported information from Siemens Dosimetry Services comprises their selection of dosemeters and processing equipment including service history, a description of their dose computation algorithm, and detailed results of their testing against DOELAP standards. Battelle Pacific Northwest Laboratories (PNL) provides a description of their dosemeters and equipment with service history; in addition, a discussion of their new neural network approach to a dose computation algorithm and test results from that algorithm are presented. (Author)

  4. Chemical dosimetry principles in high dose dosimetry

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  5. Assistance to Oil and Gas State Agencies and Industry through Continuation of Environmental and Production Data Management and a Water Regulatory Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Grunewald, Ben; Arthur, Dan; Langhus, Bruce; Gillespie, Tom; Binder, Ben; Warner, Don; Roberts, Jim; Cox, D.O.

    2002-05-31

    This grant project was a major step toward completion of the Risk Based Data Management System (RBDMS) project. Additionally the project addresses the needs identified during the projects initial phases. By implementing this project, the following outcomes were sought: (1) State regulatory agencies implemented more formalized environmental risk management practices as they pertain to the production of oil and gas, and injection via Class II wells. (2) Enhancement of oil and gas production by implementing a management system supporting the saving of abandoned or idle wells located in areas with a relatively low environmental risk of endangering underground sources of drinking water (USDWs) in a particular state. (3) Verification that protection of USDWs is adequate and additional restrictions of requirements are not necessary in areas with a relatively low environmental risk. (4) Standardization of data and information maintained by state regulatory agencies and decrease the regulatory cost burden on producers operating in multiple states, and (5) Development of a system for electronic data transfer among operators and state regulatory agencies and reduction of overall operator reporting burdens.

  6. Relationship between Saskatchewan government regulatory agencies and the oil and gas industry

    International Nuclear Information System (INIS)

    Lechner, L.J.; Mathieson, B.

    1998-01-01

    The roles and responsibilities of various government agencies as they interact with the oil and gas industry in Saskatchewan were described. The regulatory agencies featured in this paper were Saskatchewan Energy and Mines (SEM), Saskatchewan Environment and Resource Management (SERM), and Saskatchewan Agriculture and Food (SAF). The management of land sales, seismic activities, exploration and oil and gas production activities were reviewed. While each of the agencies has a different mandate, they have a common goal regarding petroleum resources, and that is to ensure that the oil and gas industry carries out its activities in a sustainable manner while protecting and conserving the environment. The mandate of SEM is to facilitate the discovery, development and use of Saskatchewan's energy and mineral resources. SERM's mandate is to manage, enhance and protect Saskatchewan's natural and environmental resources such as fish, wildlife, lands, forests, parks, air, water and soil, for conservation, recreation, social and economic purposes. The mandate of SAF is to manage crown land in the province and to control surface access to these lands

  7. 100 years of solid state dosimetry and radiation protection dosimetry

    International Nuclear Information System (INIS)

    Bartlett, David T.

    2008-01-01

    The use of solid state detectors in radiation dosimetry has passed its 100th anniversary. The major applications of these detectors in radiation dosimetry have been in personal dosimetry, retrospective dosimetry, dating, medical dosimetry, the characterization of radiation fields, and also in microdosimetry and radiobiology research. In this introductory paper for the 15th International Conference, I shall speak of the history of solid state dosimetry and of the radiation measurement quantities that developed at the same time, mention some landmark developments in detectors and applications, speak a bit more about dosimetry and measurement quantities, and briefly look at the past and future

  8. An Assessment of the Efficiency of Government Regulatory Agencies in Nigeria. Case of the National Agency for Food and Drugs Administration and Control

    Directory of Open Access Journals (Sweden)

    Aiwanehi Barbara Ofuani

    2015-09-01

    Full Text Available This study examines Business, Government and Society interrelationships. It eventually narrowed down to assessing the efficiency of government regulatory agencies, in fulfilling the role of government in protecting consumers from unscrupulous practices of businesses. The National Agency for Food and Drugs Administration and Control (NAFDAC was chosen for the study. Since the expectations of the consumers are paramount here, the stakeholder approach method was used for assessing the efficiency of NAFDAC. Literature and previous empirical studies on the topic were examined. For representativeness, data was collected utilizing the survey research design through Questionnaire distributed to 200 respondents in some areas of Lagos Mainland in Lagos state, using the convenience sampling method. 187 copies of the questionnaire representing 93.5% were returned and usable. Descriptive statistics was used to analyze the responses to questions regarding the efficiency of NAFDAC and a hypothesis tested using a one-sample T-test. The findings ran contrary to results from some previous studies. Instead, consumer awareness of the existence of NAFDAC as a regulatory agency and its functions were established, along with a high rate of consumer education. The assessment of its efficiency also showed a high rating. Recommendations were made that the study be replicated in other states of Nigeria and further studies carried out to evaluate its efficiency under previous and current directors for improvement purposes.

  9. Comparison of Different Internal Dosimetry Systems for Selected Radionuclides Important to Nuclear Power Production

    Energy Technology Data Exchange (ETDEWEB)

    Leggett, Richard Wayne [ORNL; Eckerman, Keith F [ORNL; Manger, Ryan P [ORNL

    2013-08-01

    This report compares three different radiation dosimetry systems currently applied by various U.S. Federal agencies and dose estimates based on these three dosimetry systems for a set of radionuclides often identified in power reactor effluents. These dosimetry systems were developed and applied by the International Commission on Radiological Protection at different times over the past six decades. Two primary modes of intake of radionuclides are addressed: ingestion in drinking water and inhalation. Estimated doses to individual organs and to the whole body based on each dosimetry system are compared for each of four age groups: infant, child, teenager, and adult. Substantial differences between dosimetry systems in estimated dose per unit intake are found for some individual radionuclides, but differences in estimated dose per unit intake generally are modest for mixtures of radionuclides typically found in nuclear power plant effluents.

  10. Characterization of the thermoluminescent detectors LiF:Mg,Cu,P. Environmental dosimetry applications

    International Nuclear Information System (INIS)

    Ciocci Brazzano, Ligia; Gregori, Beatriz N.; Papadopulos, Susana B.; Carelli, Jorge L.

    2005-01-01

    Studies on thermal-luminescent properties of the LiF:Mg detectors, Cu, P enrichment with Li-7 (99.93% of Li-7 and 0.07% of Li-6): optimization of the heating profile, loss of information, detection limit and doses and energy responses are presented in this work. Their performance is compared with LiF:Mg detectors, Mg, Ti enriched with Li-7 (99.93% of Li-7 and 0.07% Li-6), which are at present used for environmental dosimetry at the Physics Dosimetry Laboratory of the Nuclear Regulatory Authority [es

  11. Clinical dosimetry in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Jovanovska, A.

    2012-01-01

    Full text: Introduction: Diagnostic and interventional procedures involving x-rays are the most significant contributor to total population dose form man made sources of ionizing radiation. Purpose and aim: X-ray imaging generally covers a diverse range of examination types, many of which are increasing in frequency and technical complexity. Materials and methods: The European Directives 96/29 and 97/43 EURATOM stress the importance of accurate dosimetry and require calibration of all measuring equipment related to application of ionizing radiation in medicine. Results: The paper gives and overview of current system of dosimetry of ionizing radiations that is relevant for metrology and clinical applications. It also reflects recently achieved international harmonization in the field promoted by International Atomic Energy Agency (IAEA). Discussion: Objectives of clinical dose measurements in diagnostic and interventional radiology are multiple, as assessment of equipment performance, or assessment of risk emerging from use of ionizing radiation Conclusion: Therefore, from the clinical point of view, the requirements for dosimeters and procedures to assess dose to standard dosimetry phantoms and patients in clinical diverse modalities, as computed tomography are presented

  12. Dosimetry

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The purpose of ionizing radiation dosimetry is the measurement of the physical and biological consequences of exposure to radiation. As these consequences are proportional to the local absorption of energy, the dosimetry of ionizing radiation is based on the measurement of this quantity. Owing to the size of the effects of ionizing radiation on materials in all of these area, dosimetry plays an essential role in the prevention and the control of radiation exposure. Its use is of great importance in two areas in particular where the employment of ionizing radiation relates to human health: radiation protection, and medical applications. Dosimetry is different for various reasons: owing to the diversity of the physical characteristics produced by different kinds of radiation according to their nature (X- and γ-photons, electrons, neutrons,...), their energy (from several keV to several MeV), the orders of magnitude of the doses being estimated (a factor of about 10 5 between diagnostic and therapeutic applications); and the temporal and spatial variation of the biological parameters entering into the calculations. On the practical level, dosimetry poses two distinct yet closely related problems: the determination of the absorbed dose received by a subject exposed to radiation from a source external to his body (external dosimetry); and the determination of the absorbed dose received by a subject owing to the presence within his body of some radioactive substance (internal dosimetry)

  13. Dosimetry Service

    CERN Multimedia

    2006-01-01

    Cern Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry Dosimetry Service is open every morning from 8.30 - 12.00. Closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after the use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel. 7 2155 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  14. Knowledge Management Implementation In Indonesia Nuclear Energy Regulatory Agency (BAPETEN)

    International Nuclear Information System (INIS)

    Nurwidi Astuti, Y.H.

    2016-01-01

    Full text: Indonesian Nuclear Energy Regulatory Agency (BAPETEN) acquires the task and function to control the safety, security and safeguards in the field of nuclear energy through the development of legislation, licensing services, inspection and enforcement. Which is supported by review and assessment, emergency preparedness. Knowledge Management (KM) is importance for BAPETEN to achieve the Regulatory body effectiveness and product innovation. The Chairman of BAPETEN has set policies statement for KM implementation. To implement a knowledge management program, BAPETEN creates KM guidelines that includes blueprint and roadmap KM programme based on a KM readiness survey. The KM readiness survey involves 20% of staff who represent each unit and discussions with the senior manager of BAPETEN, and the result of readiness survey produce 13 KM BAPETEN initiatives strategic. After the initiative strategic has been obtained, BAPETEN creates the Roadmap of BAPETEN Knowledge Management for 2015–2019 programme for KM People with the activity sozialization of KM Guidebook, workshop SMART knowledge worker, nurture Community of practices (COP) and develop social network analysis (SNE). KM Process with activity focus group discussion, KM Readyness survey, KM Statement, KM Bapeten Guidebook, knowledge mapping, knowledge harvesting. KM Technology with activity develop knowledge system or portal, e-learning. (author

  15. Dosimetry system 1986

    International Nuclear Information System (INIS)

    Woolson, William A.; Egbert, Stephen D.; Gritzner, Michael L.

    1987-01-01

    In May 1983, the authors proposed a dosimetry system for use by the Radiation Effects Research Foundation (RERF) that would incorporate the new findings and calculations of the joint United States - Japan working groups on the reassessment of A-bomb dosimetry. The proposed dosimetry system evolved from extensive discussions with RERF personnel, numerous meetings of the scientists from Japan and the United States involved in the dosimetry reassessment research, and requirements expressed by epidemiologists and radiobiologists on the various review panels. The dosimetry system proposed was based on considerations of the dosimetry requirements for the normal work of RERF and for future research in radiobiology, the computerized input data on A-bomb survivors available in the RERF data base, the level of detail, precision, and accuracy of various components of the dosimetric estimates, and the computer resources available at RERF in Hiroshima. These discussions and our own experience indicated that, in light of the expansion of computer and radiation technologies and the desire for more detail in the dosimetry, an entirely new approach to the dosimetry system was appropriate. This resulted in a complete replacement of the T65D system as distinguished from a simpler approach involving a renormalization of T65D parameters to reflect the new dosimetry. The proposed dosimetry system for RERF and the plan for implementation was accepted by the Department of Energy (DOE) Working Group on A-bomb Dosimetry chaired by Dr. R.F. Christy. The dosimetry system plan was also presented to the binational A-bomb dosimetry review groups for critical comment and was discussed at joint US-Japan workshop. A prototype dosimetry system incorporating preliminary dosimetry estimates and applicable to only a limited set of A-bomb survivors was installed on the RERF computer system in the fall of 1984. This system was successfully operated at RERF and provided an initial look at the impact of

  16. Nuclear regulatory decision making

    International Nuclear Information System (INIS)

    Wieland, Patricia; Almeida, Ivan Pedro Salati de

    2011-01-01

    The scientific considerations upon which the nuclear regulations are based provide objective criteria for decisions on nuclear safety matters. However, the decisions that a regulatory agency takes go far beyond granting or not an operating license based on assessment of compliance. It may involve decisions about hiring experts or research, appeals, responses to other government agencies, international agreements, etc.. In all cases, top management of the regulatory agency should hear and decide the best balance between the benefits of regulatory action and undue risks and other associated impacts that may arise, including issues of credibility and reputation. The establishment of a decision framework based on well established principles and criteria ensures performance stability and consistency, preventing individual subjectivity. This article analyzes the challenges to the decision-making by regulatory agencies to ensure coherence and consistency in decisions, even in situations where there is uncertainty, lack of reliable information and even divergence of opinions among experts. The article explores the basic elements for a framework for regulatory decision-making. (author)

  17. Argentine intercomparison programme for personal dosimetry

    International Nuclear Information System (INIS)

    Gregori, B.N.; Papadopulos, S.B.; Cruzate, J.; Kunst, J.J.; Saravi, M.

    2005-01-01

    Full text: In 1997 began in Argentine, sponsored by Nuclear Regulatory Authority (ARN) the intercomparison program for personal dosimetry laboratories, on a voluntary basis. Up to know 6 exercises have been done. The program began with a workshop to present the quantities, personal dose equivalent, Hp(10) and extremities dose equivalent, Hs(d). The first aim of this program was to know the true sate of personal dosimetry laboratories in the country, and then introduce the personal dose equivalent, Hp(10) into the dose measurements. The Regional Reference Center for Dosimetry (CCR), belonging to CNEA and the Physical Dosimetry Laboratory of ARN performed the irradiation. Those were done air free and on ICRU phantom, using x-ray, quality ISO: W60, W110 and W200; and 137 Cs and 60 Co gamma rays. The irradiation was made following ISO 4037 (2) recommendations. There are studied the dose, energy and angular response of the different measuring system. The range of the dose analyzed was from 0.2 mSv up to 80 mSv. The beam incidence was normal and also 20 o and 60 o . The dosimeters irradiation's were performed kerma in free in air and in phantom in order to study the availability of the service to evaluate the behavior as a function of kerma free in air or Hp(10). At the same time several items have been asked to each participant referring to the action range, the detectors characteristics, the laboratory procedures, the existence of an algorithm and its use for the dosimeter evaluation and the wish to participate in a quality assurance program. The program worked in writing a standard of personal dosimetry laboratories, that was published in 2001. In this work the results of each laboratory and its performance based on the ICRP-60 and ICRP-35 acceptance criteria are shown. Also the laboratory evolution and inquiry analyses have been included. (author)

  18. Regulatory difficulties in a developing country

    International Nuclear Information System (INIS)

    Jacobs, W.R. Jr.

    1978-01-01

    The regulatory agency assigned the task of regulating the initial entry into the field of nuclear power generation by a developing country has a very difficult job. Based on the authors' experience during the start-up and initial operation of Ko-Ri Unit I, the first power reactor in the Republic of Korea, observations on regulatory difficulties and recommendations for improved regulatory effectiveness are offered. The problem areas can be loosely grouped into three general categories: (1) Lack of adequate technical knowledge which is the basis for all effective regulation; (2) Difficulties with understanding and utilization of the required regulatory documentation; (3) Failure to establish the proper regulatory environment. Examples are cited from actual experience during the Ko-Ri Unit I start-up to demonstrate the impact that regulatory activities can have on a plant construction and testing programme. The problems encountered are not unique to developing countries but also exist in the United States of America. Recommendations are offered which should be beneficial to either newly formed regulatory agencies or agencies wishing to improve their abilities and effectiveness. These include: (1) Additional training of regulatory inspectors in plant operations; (2) Additional experience gained by participation in regulatory activities in other countries; (3) Increased attention given to regulatory documents, especially plant technical specifications; (4) Establishment of formal lines of communication between the utility and the regulatory agency; (5) Clear definition of regulatory responsibilities to avoid areas of overlapping jurisdiction; (6) Active participation by the regulatory staff very early in the project. It is hoped that these and other recommendations offered will greatly improve regulatory effectiveness and at the same time demonstrate that when the decision is made to 'go nuclear', a strong commitment must be made to develop and support a technically

  19. Radiation Dosimetry Management: Quality Assurance and Investigations

    International Nuclear Information System (INIS)

    Perle, S.

    2001-01-01

    Full text: In a litigation-prone society, it is prudent for any business to evaluate its potential exposure to legal action, initiated by either an employee or a member of the general public. This potential is exacerbated when the phobia of radiation exposure and radioactive materials is interjected into the equation. This phobia is fuelled by the perceived risks of radiation exposure, be they fact or fantasy. With the current cancer incidence rate being approximately 1 in every 2.5 individuals (for all types of cancer), it is imperative that all facilities take a proactive look at their business vulnerability. When radiation exposure is the issue, records documentation is a critical factor, and a significant amount of effort should be expended to implement a comprehensive records management system. A comprehensive Radiation Dosimetry Management Program is essential if a business is going to mitigate any regulatory or legal intervention. This lecture will address appropriate Records Quality Assurance, and, the appropriate requirements for investigations of dosimetry results. (author)

  20. Regulatory authority information system RAIS

    International Nuclear Information System (INIS)

    Ortiz, P.; Mrabit, K.; Miaw, S.

    2000-01-01

    In this lecture the principles of the regulatory authority information system (RAIS) are presented. RAIS is a tool currently being developed by the IAEA for the Regulatory Authorities. It is a part of a set of supporting actions designed to assist member states in achieving the objectives of the Model project on radiation and waste safety infrastructure. RAIS is a tool that provides the management of the Regulatory Authority with the key information needed for the planning and implementation of activities and to ensure confidence that resources are optimally used. The RAIS contains five modules: Inventory of installations and radiation sources; Authorization process; Inspection and follow-up actions; Information on personal dosimetry; Assessment of effectiveness by means of performance indicators

  1. 77 FR 8082 - Regulatory Flexibility Agenda

    Science.gov (United States)

    2012-02-13

    ... Required: Yes. Agency Contact: Alicia Goldin, Division of Trading and Markets, Securities and Exchange.../01/11 Regulatory Flexibility Analysis Required: Yes. Agency Contact: Alicia Goldin, Division of... Withdrawn 10/01/11 Regulatory Flexibility Analysis Required: Yes. Agency Contact: Alicia Goldin, Division of...

  2. Improvement of JCDS, a computational dosimetry system in JAEA for neutron capture therapy

    International Nuclear Information System (INIS)

    Kumada, Hiroaki; Yamamoto, Kazuyoshi; Matsumura, Akira; Yamamoto, Tetsuya; Nakagawa, Yoshinobu; Kageji, Teruyoshi

    2006-01-01

    JCDS, a computational dosimetry system for neutron capture therapy, was developed by Japan Atomic Energy Agency. The system has been sophisticated to facilitate dose planning so far. In dosimetry with JCDS for BNCT clinical trials at JRR-4, several absorbed doses and the dose distributions are determined by a voxel model consisted of 2x2x2mm 3 voxel cells. By using the detailed voxel model, accuracy of the dosimetry can be improved. Clinical trials for melanoma and head-and-neck cancer as well as brain tumor were started using hot version of JCDS in 2005. JCDS is also being of improved so as to enable a JCDS application to dosimetry by PHITS as well as dosimetry by MCNP. By using PHITS, total doses of a patient by a combined modality therapy, for example a combination of BNCT and proton therapy, can be estimated consistently. Moreover, PET images can be adopted in combination with CT and MRI images as a farsighted approach. JCDS became able to identify target regions by using the PET values. (author)

  3. Proceedings of the second conference on radiation protection and dosimetry

    International Nuclear Information System (INIS)

    Swaja, R.E.; Sims, C.S.

    1988-11-01

    The Second Conference on Radiation Protection and Dosimetry was held during October 31--November 3, 1988, at the Holiday Inn, Crowne Plaza Hotel in Orlando, Florida. This meeting was designed with the objectives of promoting communication among applied, research, regulatory, and standards personnel involved in radiation protection and providing them with sufficient information to evaluate their programs. To facilitate meeting these objectives, a technical program consisting of more than 75 invited and contributed oral presentations encompassing all aspects of radiation protection was prepared. General topics considered in the technical sessions included external dosimetry, internal dosimetry, calibration, standards and regulations, instrumentation, accreditation and test programs, research advances, and applied program experience. In addition, special sessions were held to afford attendees the opportunity to make short presentations of recent work or to discuss topics of general interest. This document provides a summary of the conference technical program and a partial collection of full papers for the oral presentations in order of delivery. Individual papers were processed separately for the data base

  4. Proceedings of the second conference on radiation protection and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Swaja, R. E.; Sims, C. S. [eds.

    1988-11-01

    The Second Conference on Radiation Protection and Dosimetry was held during October 31--November 3, 1988, at the Holiday Inn, Crowne Plaza Hotel in Orlando, Florida. This meeting was designed with the objectives of promoting communication among applied, research, regulatory, and standards personnel involved in radiation protection and providing them with sufficient information to evaluate their programs. To facilitate meeting these objectives, a technical program consisting of more than 75 invited and contributed oral presentations encompassing all aspects of radiation protection was prepared. General topics considered in the technical sessions included external dosimetry, internal dosimetry, calibration, standards and regulations, instrumentation, accreditation and test programs, research advances, and applied program experience. In addition, special sessions were held to afford attendees the opportunity to make short presentations of recent work or to discuss topics of general interest. This document provides a summary of the conference technical program and a partial collection of full papers for the oral presentations in order of delivery. Individual papers were processed separately for the data base.

  5. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  6. Harmonization of internal dosimetry procedures in Latin America - ARCAL/IAEA project

    Energy Technology Data Exchange (ETDEWEB)

    Melo, D.; Dantas, B.M.; Juliao, L. [Instituto de Radioprotecao e Dosimetria - Av. Salvador Allende S/N, Recreio dos Bandeirantes, RJ 22780-160 (Brazil); Cruz Suarez, R. [International Atomic Energy Agency, Vienna (Austria); Rojo, A.; Serdero, N. [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); Videla, R. [Comision Chilena de Energia Nuclear, Santiago (Chile); Puerta, J.A. [Universidad Nacional de Colombia, Medellin (Colombia); Lopez, G. [Centro de Proteccion e Higiene de las Radiaciones, Ciudad de la Habana (Cuba); Alfaro, M.M. [Instituto nacional de Investigaciones Nucleares (Mexico); Gonzales, S. [Instituto Peruano de Energia Nuclear, Lima (Peru); Hermida, J.C. [Hospital de Clinicas, Montevideo (Uruguay); Navarro, T. [Centro de Investigaciones Energeticas, Mediciones Ambientales y Tecnologicas - CIEMAT, Madrid (Spain)

    2007-07-01

    Under the auspices of the Regional Coordination Agreement for Latin America, representatives of the eight member states have participated in a project to improve radiological protection for workers exposed to unsealed sources of radiation. The design of the project was based on information obtained from a questionnaire circulated among the participants, from which the initial status of internal dosimetry services in each country was characterised. The objective of the project is to harmonize internal dosimetry procedures, with reference to International Atomic Energy Agency recommendations. After the implementation of new procedures and personnel training, four intercomparison exercises were carried out: measurement of iodine in thyroid phantoms, measurement of gamma emitters in urine samples, measurement of beta emitters in urine samples and internal dose assessments. This project has resulted in important improvements in internal dosimetry services in the region. (authors)

  7. Dosimetry

    International Nuclear Information System (INIS)

    Rezende, D.A.O. de

    1976-01-01

    The fundamental units of dosimetry are defined, such as exposure rate, absorbed dose and equivalent dose. A table is given of relative biological effectiveness values for the different types of radiation. The relation between the roentgen and rad units is calculated and the concepts of physical half-life, biological half-life and effective half-life are discussed. Referring to internal dosimetry, a mathematical treatment is given to β particle-and γ radiation dosimetry. The absorbed dose is calculated and a practical example is given of the calculation of the exposure and of the dose rate for a gama source [pt

  8. The next decade in external dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1986-10-01

    As the radiation protection community moves through the last half of the '80s and into the next decade, we can expect the requirements for external dosimetry to become increasingly more restrictive and demanding. As in other health protection fields, growing regulatory and legal pressures, together with a natural evolution in philosophy, require the health physicist to display an increasing degree of accountability, rigor, and professionalism. The good news is that, for the most part, the technology necessary to solve many of the problems will be available or not far behind. This paper describes anticipated technology. 66 refs., 10 figs

  9. In vivo dosimetry in external beam radiotherapy

    International Nuclear Information System (INIS)

    Mijnheer, Ben; Beddar, Sam; Izewska, Joanna; Reft, Chester

    2013-01-01

    In vivo dosimetry (IVD) is in use in external beam radiotherapy (EBRT) to detect major errors, to assess clinically relevant differences between planned and delivered dose, to record dose received by individual patients, and to fulfill legal requirements. After discussing briefly the main characteristics of the most commonly applied IVD systems, the clinical experience of IVD during EBRT will be summarized. Advancement of the traditional aspects of in vivo dosimetry as well as the development of currently available and newly emerging noninterventional technologies are required for large-scale implementation of IVD in EBRT. These new technologies include the development of electronic portal imaging devices for 2D and 3D patient dosimetry during advanced treatment techniques, such as IMRT and VMAT, and the use of IVD in proton and ion radiotherapy by measuring the decay of radiation-induced radionuclides. In the final analysis, we will show in this Vision 20/20 paper that in addition to regulatory compliance and reimbursement issues, the rationale for in vivo measurements is to provide an accurate and independent verification of the overall treatment procedure. It will enable the identification of potential errors in dose calculation, data transfer, dose delivery, patient setup, and changes in patient anatomy. It is the authors’ opinion that all treatments with curative intent should be verified through in vivo dose measurements in combination with pretreatment checks

  10. In vivo dosimetry in external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mijnheer, Ben [Department of Radiation Oncology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam 1066 CX (Netherlands); Beddar, Sam [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Izewska, Joanna [Division of Human Health, International Atomic Energy Agency, Vienna 1400 (Austria); Reft, Chester [Department of Radiation and Cellular Oncology, University of Chicago Medical Center, Chicago, Illinois 60637 (United States)

    2013-07-15

    In vivo dosimetry (IVD) is in use in external beam radiotherapy (EBRT) to detect major errors, to assess clinically relevant differences between planned and delivered dose, to record dose received by individual patients, and to fulfill legal requirements. After discussing briefly the main characteristics of the most commonly applied IVD systems, the clinical experience of IVD during EBRT will be summarized. Advancement of the traditional aspects of in vivo dosimetry as well as the development of currently available and newly emerging noninterventional technologies are required for large-scale implementation of IVD in EBRT. These new technologies include the development of electronic portal imaging devices for 2D and 3D patient dosimetry during advanced treatment techniques, such as IMRT and VMAT, and the use of IVD in proton and ion radiotherapy by measuring the decay of radiation-induced radionuclides. In the final analysis, we will show in this Vision 20/20 paper that in addition to regulatory compliance and reimbursement issues, the rationale for in vivo measurements is to provide an accurate and independent verification of the overall treatment procedure. It will enable the identification of potential errors in dose calculation, data transfer, dose delivery, patient setup, and changes in patient anatomy. It is the authors' opinion that all treatments with curative intent should be verified through in vivo dose measurements in combination with pretreatment checks.

  11. Providing Value to New Health Technology: The Early Contribution of Entrepreneurs, Investors, and Regulatory Agencies

    Science.gov (United States)

    Lehoux, Pascale; Miller, Fiona A.; Daudelin, Geneviève; Denis, Jean-Louis

    2017-01-01

    Background: New technologies constitute an important cost-driver in healthcare, but the dynamics that lead to their emergence remains poorly understood from a health policy standpoint. The goal of this paper is to clarify how entrepreneurs, investors, and regulatory agencies influence the value of emerging health technologies. Methods: Our 5-year qualitative research program examined the processes through which new health technologies were envisioned, financed, developed and commercialized by entrepreneurial clinical teams operating in Quebec’s (Canada) publicly funded healthcare system. Results: Entrepreneurs have a direct influence over a new technology’s value proposition, but investors actively transform this value. Investors support a technology that can find a market, no matter its intrinsic value for clinical practice or healthcare systems. Regulatory agencies reinforce the "double" value of a new technology—as a health intervention and as an economic commodity—and provide economic worth to the venture that is bringing the technology to market. Conclusion: Policy-oriented initiatives such as early health technology assessment (HTA) and coverage with evidence may provide technology developers with useful input regarding the decisions they make at an early stage. But to foster technologies that bring more value to healthcare systems, policy-makers must actively support the consideration of health policy issues in innovation policy. PMID:28949463

  12. Radiation processing dosimetry - past, present and future

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1999-01-01

    Since the two United Nations Conferences were held in Geneva in 1955 and 1958 on the Peaceful Uses of Atomic Energy and the concurrent foundation of the International Atomic Energy Agency in 1957, the IAEA has fostered high-dose dosimetry and its applications. This field is represented in industrial radiation processing, agricultural programmes, and therapeutic and preventative medicine. Such dosimetry is needed specifically for pest and quarantine control and in the processing of medical products, pharmaceuticals, blood products, foodstuffs, solid, liquid and gaseous wastes, and a variety of useful commodities, e.g. polymers, composites, natural rubber and elastomers, packaging, electronic, and automotive components, as well as in radiotherapy. Improvements and innovations of dosimetry materials and analytical systems and software continue to be important goals for these applications. Some of the recent advances in high-dose dosimetry include tetrazolium salts and substituted polydiacetylene as radiochromic media, on-line real-time as well as integrating semiconductor and diamond-detector monitors, quantitative label dosimeters, photofluorescent sensors for broad dose range applications, and improved and simplified parametric and computational codes for imaging and simulating 3D radiation dose distributions in model products. The use of certain solid-state devices, e.g. optical quality LiF, at low (down to 4K) and high (up to 500 K) temperatures, is of interest for materials testing. There have also been notable developments in experimental dose mapping procedures, e.g. 2D and 3D dose distribution analyses by flat-bed optical scanners and software applied to radiochromic and photofluorescent images. In addition, less expensive EPR spectrometers and new EPR dosimetry materials and high-resolution semiconductor diode arrays, charge injection devices, and photostimulated storage phosphors have been introduced. (author)

  13. Establishing working standards of chromosome aberrations analysis for biological dosimetry

    International Nuclear Information System (INIS)

    Bui Thi Kim Luyen; Tran Que; Pham Ngoc Duy; Nguyen Thi Kim Anh; Ha Thi Ngoc Lien

    2015-01-01

    Biological dosimetry is an dose assessment method using specify bio markers of radiation. IAEA (International Atomic Energy Agency) and ISO (International Organization for Standardization) defined that dicentric chromosome is specify for radiation, it is a gold standard for biodosimetry. Along with the documents published by IAEA, WHO, ISO and OECD, our results of study on the chromosome aberrations induced by radiation were organized systematically in nine standards that dealing with chromosome aberration test and micronucleus test in human peripheral blood lymphocytes in vitro. This standard addresses: the reference dose-effect for dose estimation, the minimum detection levels, cell culture, slide preparation, scoring procedure for chromosome aberrations use for biodosimetry, the criteria for converting aberration frequency into absorbed dose, reporting of results. Following these standards, the automatic analysis devices were calibrated for improving biological dosimetry method. This standard will be used to acquire and maintain accreditation of the Biological Dosimetry laboratory in Nuclear Research Institute. (author)

  14. The Vinca dosimetry experiment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1962-03-15

    On 15 October 1958 there occurred a very brief uncontrolled run of the zero-power reactor at the Boris Kidric Institute of Nuclear Science, Vinca, near Belgrade, Yugoslavia. During this run six persons received various doses of radiation. They were subsequently given medical treatment of a novel kind at the Curie Hospital, Paris. In atomic energy operations to date, very few accidents involving excessive radiation exposure to human beings have occurred. In fact, the cases of acute radiation injury are limited to about 30 known high exposures, few of which were in the lethal or near-lethal range. Since direct experiment to determine the effects of ionizing radiation on man is unacceptable, information on these effects has to be based on a consideration of data relating to accidental exposures, viewed in the light of the much more extensive data obtained from experiments on animals. Therefore, any direct information on the effects of radiation on humans is very valuable. The international dosimetry project described in this report was carried out at Vinca, Yugoslavia, under the auspices of the International Atomic Energy Agency to determine the precise amount of radiation to which the persons had been exposed during the accident. These dosimetry data, together with the record of the carefully observed clinical effects, are of importance both for the scientific study of radiation effects on man and for the development of methods of therapy. The experiment and measurements were carried out at the end of April 1960. The project formed part of the Agency's research programme in the field of health and safety. The results of the experiment are made available through this report to all Member States.

  15. The Vinca dosimetry experiment

    International Nuclear Information System (INIS)

    1962-03-01

    On 15 October 1958 there occurred a very brief uncontrolled run of the zero-power reactor at the Boris Kidric Institute of Nuclear Science, Vinca, near Belgrade, Yugoslavia. During this run six persons received various doses of radiation. They were subsequently given medical treatment of a novel kind at the Curie Hospital, Paris. In atomic energy operations to date, very few accidents involving excessive radiation exposure to human beings have occurred. In fact, the cases of acute radiation injury are limited to about 30 known high exposures, few of which were in the lethal or near-lethal range. Since direct experiment to determine the effects of ionizing radiation on man is unacceptable, information on these effects has to be based on a consideration of data relating to accidental exposures, viewed in the light of the much more extensive data obtained from experiments on animals. Therefore, any direct information on the effects of radiation on humans is very valuable. The international dosimetry project described in this report was carried out at Vinca, Yugoslavia, under the auspices of the International Atomic Energy Agency to determine the precise amount of radiation to which the persons had been exposed during the accident. These dosimetry data, together with the record of the carefully observed clinical effects, are of importance both for the scientific study of radiation effects on man and for the development of methods of therapy. The experiment and measurements were carried out at the end of April 1960. The project formed part of the Agency's research programme in the field of health and safety. The results of the experiment are made available through this report to all Member States

  16. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  17. Reconstructive dosimetry for cutaneous radiation syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lima, C.M.A.; Lima, A.R.; Degenhardt, Ä.L.; Da Silva, F.C.A., E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Valverde, N.J. [Fundacao Eletronuclear de Assistencia Medica, Rio de Janeiro, RJ (Brazil)

    2015-10-15

    According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry. (author)

  18. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  19. As agências reguladoras e o modelo constitucional brasileiro / Regulatory Agencies and the Constitutional Brazilian System

    Directory of Open Access Journals (Sweden)

    Ana Carolina Borges de Oliveira

    2018-05-01

    Full Text Available Purpose – This article tackles the role of the regulatory agencies and, therefore, verifies the separation of powers model adopted by the Brazilian Constitution, focused on how the constitutional Brazilian system adopted the liberal principle of the separation of powers. Methodology/approach/design – This research analyzes Montesquieu’s theory of separation of powers and its influence on the constitutional Brazilian system. It studies the model proposed by Jürgen Habermas, who proposes a discursive theory of law. Finally, it examines the regulatory phenomenon in Brazil, as well as the structure and the roles played by regulatory agencies in acts. Findings – It is concluded that the role of regulatory agencies in the constitutional Brazilian system can be framed as the new actor in the policy formation process that culminates in decisions about laws and policies. Resumo Propósito – O presente estudo pretende investigar o papel normativo das agências reguladoras e, por conseguinte, verificar se o modelo de separação de poderes adotado pela atual Constituição Federal estaria superado, ou seja, busca-se analisar se há uma incompatibilidade entre o modelo constitucional brasileiro e a atividade normativa desenvolvida pelas agências reguladoras no Brasil. Metodologia/abordagem/design – A presente pesquisa terá como pressupostos teóricos a teoria da separação de poderes desenvolvida por Montesquieu e sua influência nas ordens política e jurídica brasileiras. Adotará, também, como base teórica, o modelo proposto por Jürgen Habermas. Por fim, analisará o fenômeno regulatório no Brasil, bem como a estrutura e os papéis desempenhados pelas agências reguladoras no atual sistema; a fim de verificar se é possível defender que a teoria da separação dos poderes proposta pela Constituição Federal de 1988 está superada Resultados – Conclui-se que o papel desempenhado pelas agências reguladoras no contexto jur

  20. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    International Nuclear Information System (INIS)

    2002-01-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in 60 Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and satisfies

  1. International symposium on standards and codes of practice in medical radiation dosimetry. Book of extended synopses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    The development of radiation measurement standards by National Metrology Institutes (NMIs) and their dissemination to Secondary Standard Dosimetry Laboratories (SSDLs), cancer therapy centres and hospitals represent essential aspects of the radiation dosimetry measurement chain. Although the demands for accuracy in radiotherapy initiated the establishment of such measurement chains, similar traceable dosimetry procedures have been implemented, or are being developed, in other areas of radiation medicine (e.g. diagnostic radiology and nuclear medicine), in radiation protection and in industrial applications of radiation. In the past few years the development of primary standards of absorbed dose to water in {sup 60}Co for radiotherapy dosimetry has made direct calibrations in terms of absorbed dose to water available in many countries for the first time. Some laboratories have extended the development of these standards to high energy photon and electron beams and to low and medium energy x-ray beams. Other countries, however, still base their dosimetry for radiotherapy on air kerma standards. Dosimetry for conventional external beam radiotherapy was probably the field where standardized procedures adopted by medical physicists at hospitals were developed first. Those were related to exposure and air kerma standards. The recent development of Codes of Practice (or protocols) based on the concept of absorbed dose to water has led to changes in calibration procedures at hospitals. The International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water (TRS 398) was sponsored by the International Atomic Energy Agency (IAEA), World Health Organization (WHO), Pan-American Health Organization (PAHO) and the European Society for Therapeutic Radiology and Oncology (ESTRO) and is expected to be adopted in many countries worldwide. It provides recommendations for the dosimetry of all types of beams (except neutrons) used in external radiotherapy and

  2. A New Dual-purpose Quality Control Dosimetry Protocol for Diagnostic Reference-level Determination in Computed Tomography.

    Science.gov (United States)

    Sohrabi, Mehdi; Parsi, Masoumeh; Sina, Sedigheh

    2018-05-17

    A diagnostic reference level is an advisory dose level set by a regulatory authority in a country as an efficient criterion for protection of patients from unwanted medical exposure. In computed tomography, the direct dose measurement and data collection methods are commonly applied for determination of diagnostic reference levels. Recently, a new quality-control-based dose survey method was proposed by the authors to simplify the diagnostic reference-level determination using a retrospective quality control database usually available at a regulatory authority in a country. In line with such a development, a prospective dual-purpose quality control dosimetry protocol is proposed for determination of diagnostic reference levels in a country, which can be simply applied by quality control service providers. This new proposed method was applied to five computed tomography scanners in Shiraz, Iran, and diagnostic reference levels for head, abdomen/pelvis, sinus, chest, and lumbar spine examinations were determined. The results were compared to those obtained by the data collection and quality-control-based dose survey methods, carried out in parallel in this study, and were found to agree well within approximately 6%. This is highly acceptable for quality-control-based methods according to International Atomic Energy Agency tolerance levels (±20%).

  3. The internal dosimetry code PLEIADES.

    Science.gov (United States)

    Fell, T P; Phipps, A W; Smith, T J

    2007-01-01

    The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts-the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included.

  4. The internal dosimetry code PLEIADES

    International Nuclear Information System (INIS)

    Fell, T. P.; Phipps, A. W.; Smith, T. J.

    2007-01-01

    The International Commission on Radiological Protection (ICRP) has published dose coefficients for the ingestion or inhalation of radionuclides in a series of reports covering intakes by workers and members of the public, including children and pregnant or lactating women. The calculation of these coefficients divides naturally into two distinct parts - the biokinetic and dosimetric. This paper describes in detail the methods used to solve the biokinetic problem in the generation of dose coefficients on behalf of the ICRP, as implemented in the Health Protection Agency's internal dosimetry code PLEIADES. A summary of the dosimetric treatment is included. (authors)

  5. Internal sources dosimetry

    International Nuclear Information System (INIS)

    Savio, Eduardo

    1994-01-01

    The absorbed dose, need of estimation in risk evaluation in the application of radiopharmaceuticals in Nuclear Medicine practice,internal dosimetry,internal and external sources. Calculation methodology,Marinelli model,MIRD system for absorbed dose calculation based on biological parameters of radiopharmaceutical in human body or individual,energy of emitted radiations by administered radionuclide, fraction of emitted energy that is absorbed by target body.Limitation of the MIRD calculation model. A explanation of Marinelli method of dosimetry calculation,β dosimetry. Y dosimetry, effective dose, calculation in organs and tissues, examples. Bibliography .

  6. Fabrication data package for HEDL dosimetry in the ORNL Poolside Facility: LWR Pressure Vessel Mock-up irradiation

    International Nuclear Information System (INIS)

    Lippincott, E.P.; McElroy, W.N.; Kellogg, L.S.; Gold, R.; Guthrie, G.L.; Ruddy, F.H.; Ulseth, J.A.

    1981-09-01

    This document provides a complete description of the HEDL dosimetry inserted in the metallurgical specimen irradiation in the LWR Pressure Vessel Mock-up at the Oak Ridge Reactor Poolside Facility (PSF). This experiment is being conducted under the Nuclear Regulatory Commission sponsored program on Surveillance Dosimetry Improvement. The irradiation started April 1980 with recovery of the 2 x 10 19 (nominal fluence with E > 1 MeV) capsule in September 1980, the 4 x 10 19 surveillance capsule in November 1981 and the pressure vessel and void box capaules about August 1982

  7. IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry

    International Nuclear Information System (INIS)

    Izewska, J.; Bera, P.; Vatnitsky, S.

    2002-01-01

    Since 1969 the International Atomic Energy Agency, together with the World Health Organization, has performed postal TLD audits to verify calibration of radiotherapy beams in developing countries. The TLD programme also monitors activities of Secondary Standard Dosimetry Laboratories (SSDLs). The programme has checked approximately 4000 clinical beams in over 1100 hospitals, and in many instances significant errors have been detected in the beam calibration. Subsequent follow-up actions help to resolve the discrepancies, thus preventing further mistreatment of patients. The audits for SSDLs check the implementation of the dosimetry protocol in order to assure proper dissemination of dosimetry standards to the end-users. The TLD audit results for SSDLs show good consistency in the basic dosimetry worldwide. New TLD procedures and equipment have recently been introduced by the IAEA that include a modified TLD calibration methodology and computerised tools for automation of dose calculation from TLD readings. (author)

  8. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2008-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11. Now in it's fourth edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Laboratory Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by U.S. Nuclear Regulatory Commission (NRC) regulations. The U.S. Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). One of the goals of this current revision was the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to U.S. personal dosemeter performance testing. The testing philosophy of ANSI/HPS N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. In this paper, the history of performance testing in the U.S. is briefly reviewed. Also described is the revision that produced the fourth edition of this standard, which has taken place over the last three years (2005-2008) by a working group representing national standards laboratories, government laboratories, the military, dosimetry vendors, universities and the nuclear power industry. (author)

  9. 76 FR 59066 - Notice of Regulatory Review Plan

    Science.gov (United States)

    2011-09-23

    ... [No. 2011-N-10] Notice of Regulatory Review Plan AGENCY: Federal Housing Finance Agency. ACTION... of and requesting comments on the FHFA interim regulatory review plan for review of existing... comments on all aspects of the interim regulatory review plan, including legal and policy considerations...

  10. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  11. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  12. Applications of gel dosimetry

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S

    2004-01-01

    Gel dosimetry has been examined as a clinical dosimeter since the 1950s. During the last two decades, however, a rapid increase in the number of investigators has been seen, and the body of knowledge regarding gel dosimetry has expanded considerably. Gel dosimetry is still considered a research project, and the introduction of this tool into clinical use is proceeding slowly. This paper will review the characteristics of gel dosimetry that make it desirable for clinical use, the postulated and demonstrated applications of gel dosimetry, and some complications, set-backs, and failures that have contributed to the slow introduction into routine clinical use

  13. Synthetic diamond devices for medical dosimetry applied to radiotherapy

    International Nuclear Information System (INIS)

    Descamps, C.

    2007-06-01

    The aim of this thesis, lead in the framework of an integrated European project entitled M.A.E.S.T.R.O. for ' Methods and Advanced Equipment for Simulation and Treatment in Radio Oncology', was to develop and test synthetic diamond detector in clinical environment for new modalities used in radiotherapy. Diamond is a good candidate for the detection of high energy beams in medical fields. It can be used for passive dosimetry, as thermoluminescent dosimeters or for active dosimetry as ionisation chambers. These two applications are presented here. Concerning the thermoluminescence, several impurities or dopants (boron, phosphorus, and nitrogen) have been incorporated in the diamond films during growth, in order to modify the material dosimetric properties and a detailed study of nitrogen-containing films is proposed. The second part presents the results obtained in active dosimetry. Two guide lines were followed: the measurement set-up optimisation and the material modification. The first dosimetric studies under radiotherapy beams concerning nitrogen-containing polycrystalline diamond as well as high purity single crystal diamond are conclusive. The detectors behaviours are in agreement with the recommendations of the International Atomic Energy Agency (IAEA). (author)

  14. Management of individual and collective dosimetry at Fessenheim nuclear plant. Evaluation after refueling shutdown

    International Nuclear Information System (INIS)

    Lamarre, D.; Waller, A.

    1980-01-01

    The principle of dosimetry management chosen by Fessenheim nuclear power station was originally consisted of two phases: - an automatic acquisition of individual doses realized by stylodosimeter readers; - a deferred data processing by computer. The whole system has not been used during the shutdown for the first refuelling of unit number one in view of encountered difficulties with perfecting of automatic readers prototype, this last phase has been replaced by a manual acquisition of doses. The dosimetry data processing has two main objects: - supervision of individual dosimetry for people who work in the nuclear power station; - knowledge of doses assigned for each working and equipment. Moreover, a first dosimetric result of the shutdown for refuelling of unit number one, enables to notice the workings which doses are the most important and written in percentage of total doses: regulatory controls: about 19%; - steam generators working: 16%; - working decontamination and making health physics screen (lock chamber) 10% [fr

  15. MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  16. Preclinical acute toxicity, biodistribution, pharmacokinetics, radiation dosimetry and microPET imaging studies of ["1"8F]fluorocholine in mice

    International Nuclear Information System (INIS)

    Silveira, Marina B.; Ferreira, Soraya M.Z.M.D.; Nascimento, Leonardo T.C.; Costa, Flávia M.; Mendes, Bruno M.; Ferreira, Andrea V.; Malamut, Carlos; Silva, Juliana B.; Mamede, Marcelo

    2016-01-01

    ["1"8F]Fluorocholine (["1"8F]FCH) has been proven to be effective in prostate cancer. Since ["1"8F]FCH is classified as a new radiopharmaceutical in Brazil, preclinical safety and efficacy data are required to support clinical trials and to obtain its approval. The aim of this work was to perform acute toxicity, biodistribution, pharmacokinetics, radiation dosimetry and microPET imaging studies of ["1"8F]FCH. The results could support its use in nuclear medicine as an important piece of work for regulatory in Brazil. - Highlights: • Data demonstrated the high quality, safety and effectiveness of ["1"8F]FCH. • ["1"8F]FCH preclinical profile is in accordance with previously published. • Toxicity, distribution, kinetics and radiation dosimetry were well characterized. • The results are important for regulatory issues in Brazil and other countries.

  17. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 72155 http://cern.ch/rp-dosimetry

  18. Thermoluminescence in medical dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  19. Neutron dosimetry - A review

    Energy Technology Data Exchange (ETDEWEB)

    Baum, J W

    1955-03-29

    This review summarizes information on the following subjects: (1) physical processes of importance in neutron dosimetry; (2) biological effects of neutrons; (3) neutron sources; and (4) instruments and methods used in neutron dosimetry. Also, possible improvements in dosimetry instrumentation are outlined and discussed. (author)

  20. JENDL Dosimetry File

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu; Iguchi, Tetsuo; Kobayashi, Katsuhei; Iwasaki, Shin; Sakurai, Kiyoshi; Ikeda, Yujiro; Nakagawa, Tsuneo.

    1992-03-01

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d, n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form. (author) 76 refs

  1. JENDL Dosimetry File

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Masaharu; Iguchi, Tetsuo [Tokyo Univ. (Japan). Faculty of Engineering; Kobayashi, Katsuhei [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Iwasaki, Shin [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sakurai, Kiyoshi; Ikeda, Yujior; Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1992-03-15

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d,n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form.

  2. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 7 2155 http://cern.ch/rp-dosimetry

  3. Dosimetry Service

    CERN Multimedia

    Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service Tel. 7 2155 http://cern.ch/rp-dosimetry

  4. Hazardous waste management system--Environmental Protection Agency. Notice of regulatory reform actions; request for comments.

    Science.gov (United States)

    1982-12-13

    In response to Executive Order 12291 and the President's Task Force on Regulatory Relief, the Environmental Protection Agency is reviewing and reassessing the hazardous waste regulations developed under the Resource Conservation and Recovery Act (RCRA). A variety of activities are underway that will simplify procedures and reduce paperwork, modify existing regulations to make them more workable and cost effective, and control new wastes and new processes. The purpose of this notice is to inform the public of these activities and invite comments on the general approaches being taken.

  5. The U.S. food and drug administration's dosimetry program

    International Nuclear Information System (INIS)

    Baratta, E.

    2005-01-01

    Full text: The U. S. Public Health Service's (PHS) Food and Drug Administration (FDA) (part of the PHS) has had a Dosimetry Program at the Winchester Engineering and Analytical Center (WEAC) (formerly the Northeastern Radiological Health Laboratory). This Dosimetry Program has been in place since 1961. In 1967 it was augmented by the construction of a Whole Body Counter at WEAC for measuring internal dose. The FDA's Center for Medical Devices and Radiological Health had been handling these dosimeters since 1961 and in 2000 the WEAC took over total responsibility for this program for the FDA's Office of Regulatory affairs. This program was originally setup for the radiation workers (analysts and support personnel) and later included investigators personnel working in the medical and dental x-ray field. The field laboratories began using radionuclides in 1972 and were also issued radiation dosimeters. Investigators station at border import station alter 2003 were issued as well as radiation pages as a precaution when checking imported food and other FDA regulated products. This paper will discuss the results of radiation exposure received by analyst (including whole body measurements) at WEAC and field laboratories. Also discussed will be exposures to investigators in the medical and dental field. The exposure to the investigators at the import border stations will be included even though they have not been carrying dosimeters for slightly more than a year. In general, the exposures have been well below the Nuclear Regulatory Commission regulations for radiation workers. (author)

  6. Regulatory philosophy and requirements for radiation control in Canadian uranium mine-mill facilities

    International Nuclear Information System (INIS)

    Dory, A.B.

    1981-10-01

    With the point made that radiation exposure is one of the health hazards of uranium mining and accordingly has to be controlled, the Canadian regulatory philosophy is outlined as it pertains to the uranium mining industry. Two extremes in regulatory approach are examined, and the joint regulatory process is explained. Two examples of poor management performance are given, and the role of mine unions in the regulatory process is touched upon. The development of new regulations to cover ventilation and employee training is sketched briefly. The author concludes with a general expression of objectives for the eighties which include improved personal dosimetry

  7. Dosimetry for radiation processing

    DEFF Research Database (Denmark)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both...... and sterilization dosimetry, optichromic dosimeters in the shape of small tubes for food processing, and ESR spectroscopy of alanine for reference dosimetry. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading...

  8. Synthetic diamond devices for medical dosimetry applied to radiotherapy; Etude et developpement de dispositifs en diamant synthetique pour la dosimetrie medicale: applications en radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Descamps, C

    2007-06-15

    The aim of this thesis, lead in the framework of an integrated European project entitled M.A.E.S.T.R.O. for ' Methods and Advanced Equipment for Simulation and Treatment in Radio Oncology', was to develop and test synthetic diamond detector in clinical environment for new modalities used in radiotherapy. Diamond is a good candidate for the detection of high energy beams in medical fields. It can be used for passive dosimetry, as thermoluminescent dosimeters or for active dosimetry as ionisation chambers. These two applications are presented here. Concerning the thermoluminescence, several impurities or dopants (boron, phosphorus, and nitrogen) have been incorporated in the diamond films during growth, in order to modify the material dosimetric properties and a detailed study of nitrogen-containing films is proposed. The second part presents the results obtained in active dosimetry. Two guide lines were followed: the measurement set-up optimisation and the material modification. The first dosimetric studies under radiotherapy beams concerning nitrogen-containing polycrystalline diamond as well as high purity single crystal diamond are conclusive. The detectors behaviours are in agreement with the recommendations of the International Atomic Energy Agency (IAEA). (author)

  9. Synthetic diamond devices for medical dosimetry applied to radiotherapy; Etude et developpement de dispositifs en diamant synthetique pour la dosimetrie medicale: applications en radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Descamps, C

    2007-06-15

    The aim of this thesis, lead in the framework of an integrated European project entitled M.A.E.S.T.R.O. for ' Methods and Advanced Equipment for Simulation and Treatment in Radio Oncology', was to develop and test synthetic diamond detector in clinical environment for new modalities used in radiotherapy. Diamond is a good candidate for the detection of high energy beams in medical fields. It can be used for passive dosimetry, as thermoluminescent dosimeters or for active dosimetry as ionisation chambers. These two applications are presented here. Concerning the thermoluminescence, several impurities or dopants (boron, phosphorus, and nitrogen) have been incorporated in the diamond films during growth, in order to modify the material dosimetric properties and a detailed study of nitrogen-containing films is proposed. The second part presents the results obtained in active dosimetry. Two guide lines were followed: the measurement set-up optimisation and the material modification. The first dosimetric studies under radiotherapy beams concerning nitrogen-containing polycrystalline diamond as well as high purity single crystal diamond are conclusive. The detectors behaviours are in agreement with the recommendations of the International Atomic Energy Agency (IAEA). (author)

  10. Alanine dosimetry for clinical applications. Proceedings

    International Nuclear Information System (INIS)

    Anton, M.

    2006-05-01

    The following topics are dealt with: Therapy level alanine dosimetry at the UK Nationational Physical Laboratory, alanine as a precision validation tool for reference dosimetry, composition of alanine pellet dosimeters, the angular dependence of the alanine ESR spectrum, the CIAE alanine dosimeter for radiotherapy level, a correction for temporal evolution effects in alanine dosimetry, next-generation services foe e-traceability to ionization radiation national standards, establishing e-traceability to HIST high-dose measurement standards, alanine dosimetry of dose delivery from clinical accelerators, the e-scan alanine dosimeter reader, alanine dosimetry at ISS, verification of the integral delivered dose for IMRT treatment in the head and neck region with ESR/alanine dosimetry, alanine dosimetry in helical tomotherapy beams, ESR dosimetry research and development at the University of Palermo, lithium formate as a low-dose EPR radiation dosimeter, sensitivity enhancement of alanine/EPR dosimetry. (HSI)

  11. Developments in physical dosimetry and radiation protection; Entwicklungen in der physikalischen Dosimetrie im Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Fiebich, Martin [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-07-01

    In the frame of physical dosimetry new dose units have been defined: the depth personal dose (equivalent dose in 10 mm depth) and the surface personal dose (equivalent dose in 0.07 mm depth). Physical dosimetry is applied for the determination of occupational radiation exposure, the radiation protected area control, the estimation of radiation exposure of patients during radiotherapy, for quality assurance and in research projects and optimization challenges. Developments have appeared with respect to punctual measuring chambers, eye lens dosimetry, OSL (optically stimulated luminescence) dosimetry, real-time dosimetry and Monte Carlo methods. New detection limits of about 1 micro Gy were reached.

  12. Textbook of dosimetry. 4. ed.

    International Nuclear Information System (INIS)

    Ivanov, V.I.

    1999-01-01

    This textbook of dosimetry is devoted to the students in physics and technical physics of high education institutions, confronted with different application of atomic energy as well as with protection of population and environment against ionizing radiations. Atomic energy is highly beneficial for man but unfortunately incorporates potential dangers which manifest in accidents, the source of which is either insufficient training of the personnel, a criminal negligence or insufficient reliability of the nuclear facilities. The majority of the incident and accident events have had as origin the personnel errors. This was the case with both the 'Three Miles Island' (1979) and Chernobyl (1986) NPP accidents. The dosimetry science acquires a vital significance in accident situations since the data obtained by its procedures are essential in choosing the correct immediate actions, behaviour tactics, orientation of liquidation of accident consequences as well as in ensuring the health of population. An important accent is placed in this manual on clarification of the nature of physical processes taken place in dosimetric detectors, in establishing the relation between radiation field characteristics and the detector response as well as in defining different dosimetric quantities. The terminology and the units of physical quantities is based on the international system of units. The book contains the following 15 chapters: 1. Ionizing radiation field; 2. Radiation doses; 3. Physical bases of gamma radiation dosimetry; 4. Ionization dosimetric detectors; 5. Semiconductor dosimetric detectors; 6. Scintillation detection in the gamma radiation dosimetry; 7. Luminescent methods in dosimetry; 8. The photographic and chemical methods of gamma radiation dosimetry; 9. Neutron dosimetry; 10. Dosimetry of high intensity radiation; 11. Dosimetry of high energy Bremsstrahlung; 12. Measurement of the linear energy transfer; 13. Microdosimetry; 14. Dosimetry of incorporated

  13. 75 FR 7526 - Withdrawal of Regulatory Guide

    Science.gov (United States)

    2010-02-19

    ...'s Electronic Reading Room at http://www.nrc.gov/reading-rm/doc-collections . Regulatory guides are... NUCLEAR REGULATORY COMMISSION [NRC-2010-0052] Withdrawal of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Withdrawal of Regulatory Guide 1.56, ``Maintenance of Water Purity in Boiling...

  14. Personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  15. Skin dosimetry - radiological protection aspects of skin dosimetry

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1991-01-01

    Following a Workshop in Skin Dosimetry, a summary of the radiological protection aspects is given. Aspects discussed include routine skin monitoring and dose limits, the need for careful skin dosimetry in high accidental exposures, techniques for assessing skin dose at all relevant depths and the specification of dose quantities to be measured by personal dosemeters and the appropriate methods to be used in their calibration. (UK)

  16. ESR Dosimetry

    International Nuclear Information System (INIS)

    Baffa, Oswaldo; Rossi, Bruno; Graeff, Carlos; Kinoshita, Angela; Chen Abrego, Felipe; Santos, Adevailton Bernardo dos

    2004-01-01

    ESR dosimetry is widely used for several applications such as dose assessment in accidents, medical applications and sterilization of food and other materials. In this work the dosimetric properties of natural and synthetic Hydroxyapatite, Alanine, and 2-Methylalanine are presented. Recent results on the use of a K-Band (24 GHz) ESR spectrometer in dosimetry are also presented

  17. Revisiting photodynamic therapy dosimetry: reductionist & surrogate approaches to facilitate clinical success

    Science.gov (United States)

    Pogue, Brian W.; Elliott, Jonathan T.; Kanick, Stephen C.; Davis, Scott C.; Samkoe, Kimberley S.; Maytin, Edward V.; Pereira, Stephen P.; Hasan, Tayyaba

    2016-04-01

    Photodynamic therapy (PDT) can be a highly complex treatment, with many parameters influencing treatment efficacy. The extent to which dosimetry is used to monitor and standardize treatment delivery varies widely, ranging from measurement of a single surrogate marker to comprehensive approaches that aim to measure or estimate as many relevant parameters as possible. Today, most clinical PDT treatments are still administered with little more than application of a prescribed drug dose and timed light delivery, and thus the role of patient-specific dosimetry has not reached widespread clinical adoption. This disconnect is at least partly due to the inherent conflict between the need to measure and understand multiple parameters in vivo in order to optimize treatment, and the need for expedience in the clinic and in the regulatory and commercialization process. Thus, a methodical approach to selecting primary dosimetry metrics is required at each stage of translation of a treatment procedure, moving from complex measurements to understand PDT mechanisms in pre-clinical and early phase I trials, towards the identification and application of essential dose-limiting and/or surrogate measurements in phase II/III trials. If successful, identifying the essential and/or reliable surrogate dosimetry measurements should help facilitate increased adoption of clinical PDT. In this paper, examples of essential dosimetry points and surrogate dosimetry tools that may be implemented in phase II/III trials are discussed. For example, the treatment efficacy as limited by light penetration in interstitial PDT may be predicted by the amount of contrast uptake in CT, and so this could be utilized as a surrogate dosimetry measurement to prescribe light doses based upon pre-treatment contrast. Success of clinical ALA-based skin lesion treatment is predicted almost uniquely by the explicit or implicit measurements of photosensitizer and photobleaching, yet the individualization of treatment

  18. Results of the Argentinian intercomparison on internal dosimetry – 2014. Interpretation of monitoring data for effective dose assessment due to internal exposure

    International Nuclear Information System (INIS)

    Rojo, A.M.; Puerta, N.; Gossio, S.; Gómez Parada, I.

    2015-01-01

    Internal dosimetry intercomparisons are essential for the verification of the models applied and the results consistency. To that aim, in 2014 the National Intercomparison Exercise was organized and coordinated by the Internal Dosimetry Laboratory of the Nuclear Regulatory Authority (ARN) of Argentina. Four simulated cases covering intakes of “1”3”1I, “1”3”7Cs and tritium were proposed. The exercise counted with the participation of four internal dosimetry services from the nuclear power plants (NA-SA CNA and NA-SA CNE) and the CNEA Atomic Centres: Bariloche (CAB) and Ezeiza (CAE). This report shows a complete analysis of the participant’s results in this exercise. (authors) [es

  19. Survey of regulatory agency review of generating unit performance

    International Nuclear Information System (INIS)

    Roach, E.M. Jr.; Tarletz, D.B.

    1985-01-01

    Regulatory agencies across the country are being called upon increasingly to monitor the management of electric utilities. Such activity, which once was relatively rare, is now common. Most frequently this oversight centers around the operating performance of generating units, both nuclear and fossil. There are, perhaps, several reasons for this increased interest in the efficient operation of generating units: increased fuel costs and fuel cost differentials, increased lead times and costs for construction of new generating units, and increased dependence on existing units because of construction programs being revised to meet decreased load growth. The monitoring of generating units has taken the form of after the fact evaluation of performance on a case-by-case basis and the implementation of productivity incentive programs. Performance standards are used in these contexts both to measure the adequacy of unit performance and to implement incentives in the form of rewards or penalties. The standard used may be a subjective test of prudent performance or some numerical index of plant performance, e.g., equivalent availability, capacity factor or heat rate. Some of the activity by regulators is reviewed in applying subjective and numerical standards and the considerations involved in applying such standards are discussed

  20. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  1. Clinical dosimetry

    International Nuclear Information System (INIS)

    Rassow, J.

    1973-01-01

    The main point of this paper on clinical dosimetry which is to be understood here as application of physical dosimetry on accelerators in medical practice, is based on dosimetric methodics. Following an explanation of the dose parameters and description of the dose distribution important for clinical practice as well as geometric irradiation parameters, the significance of a series of physical parameters such as accelerator energy, surface energy of average stopping power etc. is dealt with in detail. Following a section on field homogenization with bremsstrahlung and electron radiation, details on dosimetry in clinical practice are given. Finally, a few problems of dosemeter or monitor calibration on accelerators are described. The explanations are supplemented by a series of diagrams and tables. (ORU/LH) [de

  2. Fast neutron spectrometry and dosimetry; Spectrometrie et dosimetrie des neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Blaize, S; Ailloud, J; Mariani, J; Millot, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author)Fren. [French] Nous avons etudie la spectrometrie et la dosimetrie des neutrons rapides en utilisant les protons de recul qu'ils produisent dans une matiere hydrogenee. En spectrometrie, nous avons employe des emulsions nucleaires, en dosimetrie, du polyethylene recouvert de sulfure de zinc place devant un photomultiplicateur. (auteur)

  3. Dosimetry Control: Technic and methods. Proceedings of the international workshop 'Actual problems of dosimetry'

    International Nuclear Information System (INIS)

    Lyutsko, A.M.; Nesterenko, V.B.; Chudakov, V.A.; Konoplya, E.F.; Milyutin, A.A.

    1997-10-01

    There is a number of unsolved problems of both dosimetric and radiometric control, questions of the biological dosimetry, reconstruction of dozes of irradiation of the population at radiation incidents, which require coordination of efforts of scientists in various areas of a science. The submitted materials are grouped on five units: dosimetry engineering, biological dosimetry and markers of radiation impact, dosimetry of a medical irradiation, normative and measurement assurance of the dosimetric control, monitoring and reconstruction of dozes at radiation incidents

  4. 76 FR 24539 - Final Regulatory Guide: Issuance, Availability

    Science.gov (United States)

    2011-05-02

    ... site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . Electronic copies... NUCLEAR REGULATORY COMMISSION [NRC-2010-0181] Final Regulatory Guide: Issuance, Availability AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide...

  5. Non-conventional personal dosimetry techniques

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1984-01-01

    Established dosimetry has achieved a high standard in personnel monitoring. This applies particularly to photon dosimetry. Nevertheless, even in photon dosimetry, improvements and changes are being made. The reason may be technological progress, or the introduction of new tasks on the basis of the recommendations of international bodies (e.g. the new ICRU measurement unit) of national legislation. Since we are restricting ourselves here to technical trends the author would like to draw attention to various activities of current interest, e.g. the computation of receptor-related conversion coefficients from personal dose to organ or body doses, taking into account the conditions of exposure with respect to differential energy and angular distribution of the radiation field. Realistic data on exposure geometry are taken from work place analyses. Furthermore, the data banks of central personal dosimetry services are subject to statistical evaluation and radiation protection trend analysis. Technological progress and developments are considered from the point of view of personal dosimetry, partial body or extremity dosimetry and accidental dosimetry

  6. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1999-01-01

    The Dosimetry and Calibration Section fulfils two tasks within CERN's Radiation Protection Group: the Individual Dosimetry Service monitors more than 5000 persons potentially exposed to ionizing radiation on the CERN sites, and the Calibration Laboratory verifies throughout the year, at regular intervals, over 1000 instruments, monitors, and electronic dosimeters used by RP Group. The establishment of a Quality Assurance System for the Individual Dosimetry Service, a requirement of the new Swiss Ordinance for personal dosimetry, put a considerable workload on the section. Together with an external consultant it was decided to identify and then describe the different 'processes' of the routine work performed in the dosimetry service. The resulting Quality Manual was submitted to the Federal Office for Public Health in Bern in autumn. The CERN Individual Dosimetry Service will eventually be officially endorsed after a successful technical test in March 1999. On the technical side, the introduction of an automatic development machine for gamma films was very successful. It processes the dosimetric films without an operator being present, and its built-in regeneration mechanism keeps the concentration of the processing chemicals at a constant level

  7. 75 FR 42170 - Final Regulatory Guide: Issuance, Availability

    Science.gov (United States)

    2010-07-20

    ... NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2009-0425] Final Regulatory Guide: Issuance, Availability AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide...

  8. 75 FR 48381 - Final Regulatory Guide: Issuance, Availability

    Science.gov (United States)

    2010-08-10

    ... NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2010-0274] Final Regulatory Guide: Issuance, Availability AGENCY: Nuclear Regulatory Commission. ACTION: Notice of issuance and availability of Regulatory Guide...

  9. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Boyd, A.W.; Chadwick, K.H.; McDonald, J.C.; Miller, A.

    1989-01-01

    Radiation processing is a relatively young industry with broad applications and considerable commercial success. Dosimetry provides an independent and effective way of developing and controlling many industrial processes. In the sterilization of medical devices and in food irradiation, where the radiation treatment impacts directly on public health, the measurements of dose provide the official means of regulating and approving its use. In this respect, dosimetry provides the operator with a means of characterizing the facility, of proving that products are treated within acceptable dose limits and of controlling the routine operation. This book presents an up-to-date review of the theory, data and measurement techniques for radiation processing dosimetry in a practical and useful way. It is hoped that this book will lead to improved measurement procedures, more accurate and precise dosimetry and a greater appreciation of the necessity of dosimetry for radiation processing. (author)

  10. Thin film tritium dosimetry

    Science.gov (United States)

    Moran, Paul R.

    1976-01-01

    The present invention provides a method for tritium dosimetry. A dosimeter comprising a thin film of a material having relatively sensitive RITAC-RITAP dosimetry properties is exposed to radiation from tritium, and after the dosimeter has been removed from the source of the radiation, the low energy electron dose deposited in the thin film is determined by radiation-induced, thermally-activated polarization dosimetry techniques.

  11. 75 FR 22868 - Withdrawal of Regulatory Guide

    Science.gov (United States)

    2010-04-30

    ...'s public Web site under ``Regulatory Guides'' in the NRC's Electronic Reading Room at http://www.nrc.gov/reading-rm/doc-collections . Regulatory guides are also available for inspection at the NRC's... NUCLEAR REGULATORY COMMISSION [NRC-2010-0167] Withdrawal of Regulatory Guide AGENCY: Nuclear...

  12. Technical basis for nuclear accident dosimetry at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Kerr, G.D.; Mei, G.T.

    1993-08-01

    The Oak Ridge National Laboratory (ORNL) Environmental, Safety, and Health Emergency Response Organization has the responsibility of providing analyses of personnel exposures to neutrons and gamma rays from a nuclear accident. This report presents the technical and philosophical basis for the dose assessment aspects of the nuclear accident dosimetry (NAD) system at ORNL. The issues addressed are regulatory guidelines, ORNL NAD system components and performance, and the interpretation of dosimetric information that would be gathered following a nuclear accident

  13. Technical Memory 2010. Nuclear Regulatory Authority

    International Nuclear Information System (INIS)

    2010-01-01

    The technical memory 2010 of the Nuclear Regulatory Authority of Argentine Republic, compile the papers published in the subject on radiation protection and nuclear safety presented in journals, technical reports, congress or meetings of these subjects by the ARN personnel during 2010. In this edition the documents are presented on: environmental protection; safety transport of radioactive materials; regulations; licensing of medical installations; biological radiation effects; therapeutic uses of ionizing radiation and radioprotection of patients; internal dosimetry; radioactive waste management [es

  14. Technical Memory 2011. Nuclear Regulatory Authority

    International Nuclear Information System (INIS)

    2011-01-01

    The technical memory 2011 of the Nuclear Regulatory Authority of Argentine Republic, compile the papers published in the subject on radiation protection and nuclear safety presented in journals, technical reports, congress or meetings of these subjects by the ARN personnel during 2011. In this edition the documents are presented on: environmental protection; safety transport of radioactive materials; regulations; licensing of medical installations; biological radiation effects; therapeutic uses of ionizing radiation and radioprotection of patients; internal dosimetry; radioactive waste management [es

  15. Revisiting photodynamic therapy dosimetry: reductionist and surrogate approaches to facilitate clinical success

    International Nuclear Information System (INIS)

    Pogue, Brian W; Elliott, Jonathan T; Kanick, Stephen C; Davis, Scott C; Samkoe, Kimberley S; Maytin, Edward V; Pereira, Stephen P; Hasan, Tayyaba

    2016-01-01

    Photodynamic therapy (PDT) can be a highly complex treatment, with many parameters influencing treatment efficacy. The extent to which dosimetry is used to monitor and standardize treatment delivery varies widely, ranging from measurement of a single surrogate marker to comprehensive approaches that aim to measure or estimate as many relevant parameters as possible. Today, most clinical PDT treatments are still administered with little more than application of a prescribed drug dose and timed light delivery, and thus the role of patient-specific dosimetry has not reached widespread clinical adoption. This disconnect is at least partly due to the inherent conflict between the need to measure and understand multiple parameters in vivo in order to optimize treatment, and the need for expedience in the clinic and in the regulatory and commercialization process. Thus, a methodical approach to selecting primary dosimetry metrics is required at each stage of translation of a treatment procedure, moving from complex measurements to understand PDT mechanisms in pre-clinical and early phase I trials, towards the identification and application of essential dose-limiting and/or surrogate measurements in phase II/III trials. If successful, identifying the essential and/or reliable surrogate dosimetry measurements should help facilitate increased adoption of clinical PDT. In this paper, examples of essential dosimetry points and surrogate dosimetry tools that may be implemented in phase II/III trials are discussed. For example, the treatment efficacy as limited by light penetration in interstitial PDT may be predicted by the amount of contrast uptake in CT, and so this could be utilized as a surrogate dosimetry measurement to prescribe light doses based upon pre-treatment contrast. Success of clinical ALA-based skin lesion treatment is predicted almost uniquely by the explicit or implicit measurements of photosensitizer and photobleaching, yet the individualization of treatment

  16. Fundamentals of x-ray dosimetry

    International Nuclear Information System (INIS)

    Roesch, W.C.

    1976-01-01

    Fundamental information about x-ray dosimetry is presented. Definitions are given and expanded on for dose, absorbed dose including microdosimetry, radiation physics (properties of the radiation that are important to dosimetry), and dosimetry (how the properties are dealt with in determining dose). 5 figs, 12 refs

  17. Thermoluminescent dosimetry in veterinary diagnostic radiology

    International Nuclear Information System (INIS)

    Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.

    2012-01-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.

  18. 2014 White Paper on recent issues in bioanalysis: a full immersion in bioanalysis (Part 2 - hybrid LBA/LCMS, ELN & regulatory agencies' input).

    Science.gov (United States)

    Dufield, Dawn; Neubert, Hendrik; Garofolo, Fabio; Kirkovsky, Leo; Stevenson, Lauren; Dumont, Isabelle; Kaur, Surinder; Xu, Keyang; Alley, Stephen C; Szapacs, Matthew; Arnold, Mark; Bansal, Surendra; Haidar, Sam; Welink, Jan; Le Blaye, Olivier; Wakelin-Smith, Jason; Whale, Emma; Ishii-Watabe, Akiko; Bustard, Mark; Katori, Noriko; Amaravadi, Lakshmi; Aubry, Anne-Françoise; Beaver, Chris; Bergeron, Annik; Cai, Xiao-Yan; Cojocaru, Laura; DeSilva, Binodh; Duggan, Jeff; Fluhler, Eric; Gorovits, Boris; Gupta, Swati; Hayes, Roger; Ho, Stacy; Ingelse, Benno; King, Lindsay; Lévesque, Ann; Lowes, Steve; Ma, Mark; Musuku, Adrien; Myler, Heather; Olah, Timothy; Patel, Shefali; Rose, Mark; Schultz, Gary; Smeraglia, John; Swanson, Steven; Torri, Albert; Vazvaei, Faye; Wilson, Amanda; Woolf, Eric; Xue, Li; Yang, Tong-Yuan

    2014-01-01

    The 2014 8th Workshop on Recent Issues in Bioanalysis (8th WRIB), a 5-day full immersion in the evolving field of bioanalysis, took place in Universal City, California, USA. Close to 500 professionals from pharmaceutical and biopharmaceutical companies, contract research organizations and regulatory agencies worldwide convened to share, review, discuss and agree on approaches to address current issues of interest in bioanalysis. The topics covered included both small and large molecules, and involved LCMS, hybrid LBA/LCMS, LBA approaches and immunogenicity. From the prolific discussions held during the workshop, specific recommendations are presented in this 2014 White Paper. As with the previous years' editions, this paper acts as a practical tool to help the bioanalytical community continue advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2014 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 2) covers the recommendations for Hybrid LBA/LCMS, Electronic Laboratory Notebook and Regulatory Agencies' Input. Part 1 (Small molecules bioanalysis using LCMS) was published in the Bioanalysis issue 6(22) and Part 3 (Large molecules bioanalysis using LBA and Immunogenicity) will be published in the Bioanalysis issue 6(24).

  19. Sixth symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    1987-01-01

    This booklet contains all abstracts of papers presented in 13 sessions. Main topics: Cross sections and Kerma factors; analytical radiobiology; detectors for personnel monitoring; secondary charged particles and microdosimetric basis of q-value for neutrons; personnel dosimetry; concepts for radiation protection; ambient monitoring; TEPC and ion chambers in radiation protection; beam dosimetry; track detectors (CR-39); dosimetry at biomedical irradiation facilities; health physics at therapy facilities; calibration for radiation protection; devices for beam dosimetry (TLD and miscellaneous); therapy and biomedical irradiation facilities; treatment planning. (HP)

  20. Environmental dosimetry

    International Nuclear Information System (INIS)

    Gold, R.

    1977-01-01

    For more than 60 years, natural radiation has offered broad opportunities for basic research as evidenced by many fundamental discoveries. Within the last decade, however, dramatic changes have occurred in the motivation and direction of this research. The urgent need for economical energy sources entailing acceptably low levels of environmental impact has compelled the applied aspects of our radiation environment to become overriding considerations. It is within this general framework that state-of-the-art environmental dosimetry techniques are reviewed. Although applied motivation and relevance underscores the current milieu for both reactor and environmental dosimetry, a perhaps even more unifying force is the broad similarity of reactor and environmental radiation fields. In this review, a comparison of these two mixed radiation fields is presented stressing the underlying similarities that exist. On this basis, the evolution of a strong inner bond between dosimetry methods for both reactor and environmental radiation fields is described. The existence of this bond will be illustrated using representative examples of observed spectra. Dosimetry methods of particularly high applicability for both of these fields are described. Special emphasis is placed on techniques of high sensitivity and absolute accuracy which are capable of resolving the components of these mixed radiation fields

  1. 75 FR 79049 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-12-17

    ... site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . The regulatory... NUCLEAR REGULATORY COMMISSION [NRC-2008-0427] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 3.12...

  2. 75 FR 45173 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-08-02

    ... ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . In addition, regulatory guides are... NUCLEAR REGULATORY COMMISSION [NRC-2008-0638] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.151...

  3. 76 FR 18262 - Notice of issuance of Regulatory Guide

    Science.gov (United States)

    2011-04-01

    ... site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . The regulatory... NUCLEAR REGULATORY COMMISSION [NRC-2009-0277] Notice of issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.44...

  4. 76 FR 14107 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2011-03-15

    ... site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . The regulatory... NUCLEAR REGULATORY COMMISSION [NRC-2009-0276] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.43...

  5. 76 FR 14108 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2011-03-15

    ... site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . The regulatory... NUCLEAR REGULATORY COMMISSION [NRC-2009-0275] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.50...

  6. Nuclear accident dosimetry

    International Nuclear Information System (INIS)

    1982-01-01

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  7. Nuclear accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-12-31

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  8. 78 FR 44165 - Nuclear Regulatory Commission Enforcement Policy

    Science.gov (United States)

    2013-07-23

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0159] Nuclear Regulatory Commission Enforcement Policy AGENCY: Nuclear Regulatory Commission. ACTION: Enforcement policy; request for comment. SUMMARY: The U.S... Policy. In SRM-SECY-12-0047, ``Revisions to the Nuclear Regulatory Commission Enforcement Policy,'' dated...

  9. Quantitative imaging for clinical dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bardies, Manuel [INSERM U601, 9 Quai Moncousu, 44093 Nantes (France)]. E-mail: manu@nantes.inserm.fr; Flux, Glenn [Department of Physics, Royal Marsden NHS Trust, Sutton (United Kingdom); Lassmann, Michael [Department of Nuclear Medicine, Julis-Maximilians University, Wuerzburg (Germany); Monsieurs, Myriam [Department of Health Physics, University of Ghent, 9000 Ghent (Belgium); Savolainen, Sauli [Department of Physical Sciences, University of Helsinki and HUS, Helsinki Medical Imaging Center, Helsinki University Central Hospital (Finland); Strand, Sven-Erik [Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University (Sweden)

    2006-12-20

    Patient-specific dosimetry in nuclear medicine is now a legal requirement in many countries throughout the EU for targeted radionuclide therapy (TRT) applications. In order to achieve that goal, an increased level of accuracy in dosimetry procedures is needed. Current research in nuclear medicine dosimetry should not only aim at developing new methods to assess the delivered radiation absorbed dose at the patient level, but also to ensure that the proposed methods can be put into practice in a sufficient number of institutions. A unified dosimetry methodology is required for making clinical outcome comparisons possible.

  10. Expert views on regulatory preparedness for managing the risks of nanotechnologies.

    Directory of Open Access Journals (Sweden)

    Christian E H Beaudrie

    Full Text Available The potential and promise of nanotechnologies depends in large part on the ability for regulatory systems to assess and manage their benefits and risks. However, considerable uncertainty persists regarding the health and environmental implications of nanomaterials, hence the capacity for existing regulations to meet this challenge has been widely questioned. Here we draw from a survey (N=254 of US-based nano-scientists and engineers, environmental health and safety scientists, and regulatory scientists and decision-makers, to ask whether nano experts regard regulatory agencies as prepared for managing nanomaterial risks. We find that all three expert groups view regulatory agencies as unprepared. The effect is strongest for regulators themselves, and less so for scientists conducting basic, applied, or health and safety work on nanomaterials. Those who see nanotechnology risks as novel, uncertain, and difficult to assess are particularly likely to see agencies as unprepared. Trust in regulatory agencies, views of stakeholder responsibility regarding the management of risks, and socio-political values were also found to be small but significant drivers of perceived agency preparedness. These results underscore the need for new tools and methods to enable the assessment of nanomaterial risks, and to renew confidence in regulatory agencies' ability to oversee their growing use and application in society.

  11. Gaining competitive advantage in personal dosimetry services through ISO 9001 certification

    International Nuclear Information System (INIS)

    Noriah, M.A.

    2005-01-01

    Full text: In Malaysia, the harmonization of dose monitoring for almost 12,000 radiation workers is assigned to the Secondary Standard Dosimetry Laboratory of Malaysian Institute for Nuclear Technology Research, SSDL-MINT. Established in 1980, SSDL-MINT is responsible for improving personal and workplace safety by providing high quality personal dosimetry services. It is important to demonstrate that the performance of personal dosimetry meets recognized standards, to ensure radiation doses to individual workers are within the safe limits and to verify compliance with dose limits. Concern on the quality of personal dosimetry service began to be expressed in 2000. The concern led to the ISO certification, which brought an unprecedented effort characterized by high degree coordination, proper documentation and well trained of personal dosimetry operators. These huge efforts resulted with certification ISO 9002:1994 by the SIRIM International QAS Sdn. Bhd. in January 2002. The adoption of these requirements for the ISO 9002 standard makes routine handling of the process easier, and increases the reliability and effectiveness of the services. This helps to increase the quality and uniformity of personal dosimetry. The revision of the ISO 9002:1994 to ISO 9001:2000 necessitated SSDL-MINT revising its quality management system. The work began in middle 2002, and by May 2003, SSDL-MINT has been upgraded to ISO 9001:2000. Certification to the ISO 9001:2000 demonstrates our ability to consistency provide service that meets the requirements of the customer and the regulatory authority. These includes: improved consistency of service / product performance and therefore higher customer satisfaction levels; uniformity in work processes across organizations; simplified and more uniform structure for quality documents; improved customer perception of the organizations image, culture and performance; reduced number of product and process non-conformances; greater employee

  12. Internal Dosimetry for Nuclear Power Program

    International Nuclear Information System (INIS)

    Wo, Y.M.

    2011-01-01

    Internal dosimetry which refers to dosage estimation from internal part of an individual body is an important and compulsory component in order to ensure the safety of the personnel involved in operational of a Nuclear Power Program. Radionuclides particle may deposit in the human being through several pathways and release wave and/or particle radiation to irradiate that person and give dose to body until it been excreted or completely decayed from the body. Type of radionuclides of concerning, monitoring program, equipment's and technique used to measure the concentration level of such radionuclides and dose calculation will be discussed in this article along with the role and capability of Malaysian Nuclear Agency. (author)

  13. Dosimetry through the Secondary Laboratory of Dosimetric Calibration of Mexico

    International Nuclear Information System (INIS)

    Tovar M, V.M.; Alvarez R, J.T.; Medina O, V.P.; Vergara M, F.; Anaya M, R.; Cejudo A, J.; Salinas L, B.

    2004-01-01

    In the beginnings of the sixty years an urgent necessity is presented mainly in the developing countries, of improving in important form the accuracy in the dosimetry of external faces in therapy of radiations (radiotherapy centers), mainly in the calibration of c linical dosemeters . In 1976 the International Atomic Energy Agency, (IAEA), and the World Health Organization, (WHO), they carried out a mutual agreement with regard to the establishment and operation of a net of Secondary Patron Laboratories of Dosimetry, (LSCD). The necessity to establish measure patterns in the field of the dosimetry of the ionizing radiations, is necessary, to have an accuracy but high in the dosimetry of the radiation beams in therapy which is highly dependent of the dose given to the tumor of those patient with cancer. Similar levels of accuracy are required in protection measures to the radiation with an acceptable smaller accuracy, however, when the personal dosemeters are used to determine the doses received by the individuals under work conditions, such mensurations in therapy of radiations and radiological protection will have traceability through a chain of comparisons to primary or national patterns. The traceability is necessary to assure the accuracy and acceptability of the dosimetric measures, as well as, the legal and economic implications. The traceability is also necessary in the dosimetry of high dose like in the sterilization of different products. The main function of the LSCD is to provide a service in metrology of ionizing radiations, maintaining the secondary or national patterns, which have a traceability to the International System of measures, which is based for if same in the comparison of patterns in the Primary Laboratories of Dosimetry (LPD) under the auspice of the International Office of Weights and Measure (BIPM). The secondary and national patterns in the LSCD constitute in Mexico, the national patterns of the magnitudes in the dosimetry of the

  14. Personnel Dosimetry for Radiation Accidents. Proceedings of a Symposium on Personnel Dosimetry for Accidental High-Level Exposure to External and Internal Radiation

    International Nuclear Information System (INIS)

    1965-01-01

    Accidents involving the exposure of persons to high levels of radiation have been few in number and meticulous precautions are taken in an effort to maintain this good record. When, however, such an accident does occur, a timely estimate of the dose received can be of considerable help to the physician in deciding whether a particular person requires medical treatment, and in selecting the most appropriate treatment. Individual dosimetry provides the physical basis for relating the observed effects to those in other accident cases, to other human data, and to data from animal experiments, thus providing an important aid to rational treatment and to the accumulation of a meaningful body of knowledge on the subject. It is most important therefore that, where there is a possibility of receiving high-level exposure, methods of personnel dosimetry should be available that would provide the dosimetric information most useful to the physician. Provision of good personnel dosimetry for accidental high-level exposure is in many cases an essential part of emergency planning because the information provided may influence emergency and rescue operations, and can lead to improved accident preparedness. Accordingly, the International Atomic Energy Agency and the World Health Organization jointly organized the Symposium on Personnel Dosimetry for Accidental High-Level Exposure to External and Internal Radiation for the discussion of such methods and for a critical review of the procedures adopted in some of the radiation accidents that have already occurred. The meeting was attended by 179 participants from 34 countries and from five other international organizations. The papers presented and the ensuing discussions are published in these Proceedings. It is hoped that the Proceedings will be of help to those concerned with the organization and development of wide-range personnel monitoring systems, and with the interpretation of the results provided

  15. Alanine EPR dosimetry of therapeutic irradiators

    International Nuclear Information System (INIS)

    Bugay, O.; Bartchuk, V.; Kolesnik, S.; Mazin, M.; Gaponenko, H.

    1999-01-01

    The high-dose alanine EPR dosimetry is a very precise method in the dose range 1-100 kGy. The system is used generally as the standard high-dose transfer dosimetry in many laboratories. This is comparatively expensive technique so it is important to use it as a more universal dosimetry system also in the middle and low dose ranges. The problems of the middle-dose alanine dosimetry are discussed and the solution of several problems is proposed. The alanine EPR dosimetry has been applied to the dose measurements of medical irradiators in the Kiev City Oncology Center. (author)

  16. 75 FR 52999 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-08-30

    ... site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . In addition... NUCLEAR REGULATORY COMMISSION [NRC-2009-0556] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 8.35...

  17. 75 FR 45171 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-08-02

    ... ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ and through the NRC's Agencywide... NUCLEAR REGULATORY COMMISSION [NRC-2010-0072] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 3.13...

  18. 75 FR 37842 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-06-30

    ... site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . In addition... NUCLEAR REGULATORY COMMISSION [NRC-2009-0396] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 2.5...

  19. 75 FR 43207 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-07-23

    ... NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2009-0282] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.141...

  20. 75 FR 33361 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-06-11

    ....gov/reading-rm/doc-collections/ . In addition, regulatory guides are available for inspection at the... NUCLEAR REGULATORY COMMISSION [NRC-2009-0308] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.28...

  1. 75 FR 16525 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-04-01

    ... http://www.nrc.gov/reading-rm/doc-collections/ . In addition, regulatory guides are available for... NUCLEAR REGULATORY COMMISSION [NRC-2009-0413] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.11...

  2. 75 FR 27599 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-05-17

    ...'' at http://www.nrc.gov/reading-rm/doc-collections/ . In addition, regulatory guides are available for... NUCLEAR REGULATORY COMMISSION [NRC-2009-0492] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of issuance and availability of Regulatory Guide 6.7...

  3. Comparison of Real-Time Intraoperative Ultrasound-Based Dosimetry With Postoperative Computed Tomography-Based Dosimetry for Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Shi Peipei; Liu Bingren; Gupta, Nilendu; Bahnson, Robert R.; Wang, Jian Z.

    2008-01-01

    Purpose: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. Methods and Materials: Between December 2001 and November 2002, 82 patients underwent 103 Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. Results: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm 3 , respectively, much lower than the 159 Gy and 0.65 cm 3 obtained using CT-based dosimetry. Conclusion: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or

  4. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both by international organizations (IAEA) and national laboratories have helped to improve the reliability of dose measurements. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading to traceable and reliable dosimetry are discussed. (author)

  5. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Xu Zhiyong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  6. 11. International conference on solid radiation dosimetry

    International Nuclear Information System (INIS)

    Krylova, I.V.

    1996-01-01

    The main problems discussed during the international conference on solid radiation dosimetry which took place in June 1995 in Budapest are briefly considered. These are the basic physical processes, materials applied for dosimetry, special techniques, personnel monitoring, monitoring of environmental effects, large-dose dosimetry, clinic dosimetry, track detector used for dosimetry, dosimetry in archaeology and geology, equipment and technique for dosimetric measurements. The special attention was paid to superlinearity in the TLD-100 (LiF, Mg, Ti) response function when determining doses of gamma radiation, heavy charged particles, low-energy particle fluxes in particular. New theoretical models were considered

  7. 75 FR 16202 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-03-31

    ... Guides'' at http://www.nrc.gov/reading-rm/doc-collections/ . In addition, regulatory guides are available... NUCLEAR REGULATORY COMMISSION [NRC-2008-0644] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide (RG) 1.126...

  8. 75 FR 81675 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-12-28

    ... through the NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc... NUCLEAR REGULATORY COMMISSION [NRC-2010-0031] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 4.16...

  9. 75 FR 20399 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-04-19

    ... the NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2009-0418] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 6.9...

  10. 76 FR 31382 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2011-05-31

    ... the NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2010-0287] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 8.2...

  11. A microcomputer controlled thermoluminescence dosimetry system

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Kicken, P.J.H.

    1980-01-01

    Using a microcomputer, an automatic thermoluminescence dosimetry system for personal dosimetry and thermoluminescence detector (TLD) research was developed. Process automation, statistical computation and dose calculation are provided by this microcomputer. Recording of measurement data, as well as dose record keeping for radiological workers is carried out with floppy disk. The microcomputer also provides a human/system interface by means of a video display and a printer. The main features of this dosimetry system are its low cost, high degree of flexibility, high degree of automation and the feasibility for use in routine dosimetry as well as in TLD research. The system is in use for personal dosimetry, environmental dosimetry and for TL-research work. Because of its modular set-up several components of the system are in use for other applications, too. The system seems suited for medium sized health physics groups. (author)

  12. Comparison of absorbed dose determinations using the IAEA dosimetry protocol and the ferrous sulphate dosimeter

    International Nuclear Information System (INIS)

    Mattsson, Olof

    1988-01-01

    In 1985 a comparison of different revised protocols for the dosimetry of high-energy photon and electron beams was published (Mattsson, 1985). The conclusions were that the agreement in absorbed dose to water determined using the different protocols is very good and that the agreement between ionization chamber and ferrous sulphate dosimetry is generally good. For electron beams the differences obtained with the ionization chamber and ferrous sulphate dosimeters were up to about 2%. The influence of the energy and angular distribution of the electron beams on the ionization chamber dosimetry is not fully considered in the dosimetry protocols. The basis for the ionization chamber dosimetry has recently been changed when the Bureau International des Poids et Mesures (BIPM) in 1986 changed the air-kerma standard. The reason was the adaption of the new stopping-power values reported in the ICRU Report No. 37. To achieve consistency in the ionization chamber dosimetry the interaction coefficients and correction factors given in the dosimetry protocols should also be based on the same set of stopping-power values. This is not the case with the protocols included in the comparison made by Mattsson. However, in the international code of practice by the International Atomic Energy Agency (IAEA, 1987) the new stopping-power values have been used. The formalism is the same as in most of the previous protocols. Mattsson et al. (1989) have shown that the differences in the various steps cancel out for the protocols published by NACP (1980) and by IAEA (1987) for cobalt-60 gamma quality. However, it is also of interest to investigate the influence of the new air-kerma standard and the new values on coefficients and factors given in the IAEA protocol for other beam qualities. Therefore, the data given by Mattsson (1985) have been recalculated using the new air-kerma standard and the IAEA protocol

  13. 40 CFR 73.86 - State regulatory autonomy.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false State regulatory autonomy. 73.86 Section 73.86 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... regulatory autonomy. Nothing in this subpart shall preclude a State or State regulatory authority from...

  14. The role of radiation regulatory agencies of the Republic of the Philippines in the education and training of workers occupationally exposed to radiation

    International Nuclear Information System (INIS)

    Perio Peralta, Agnette de

    2008-01-01

    In the Republic of the Philippines, there are two national radiation regulatory agencies. One is the Philippine Nuclear Research Institute (PNRI) which has the regulatory mandate over radioactive materials. The other one is the Bureau of Health Devices and Technology (BHDT) which has the regulatory mandate over radiation devices. Since a major requirement in regulating use of radiation sources is the appropriate qualification of the workers occupationally exposed to radiation, the paper discusses the strategies and activities of these two agencies to ensure that these workers have the necessary education and training to do their work properly. Some of these are the conduct of training courses in cooperation with the relevant professional societies, conduct of distance aided training in cooperation with the IAEA, initiation and active involvement in the establishment and continued existence of the masteral degree program in medical physics which was established with IAEA technical assistance, assistance to lawmakers in drafting pertinent legislation, and creation of joint technical working groups to ensure harmonization of standards and regulations, among others. The Philippines has adopted a national policy that users of radiation and radioactive materials have the primary responsibility for radiation safety. The PNRI and the BHDT have adopted strategies which have been very useful in the effective implementation of their regulations. (author)

  15. Characterising an aluminium oxide dosimetry system.

    Science.gov (United States)

    Conheady, Clement F; Gagliardi, Frank M; Ackerly, Trevor

    2015-09-01

    In vivo dosimetry is recommended as a defence-in-depth strategy in radiotherapy treatments and is currently employed by clinics around the world. The characteristics of a new optically stimulated luminescence dosimetry system were investigated for the purpose of replacing an aging thermoluminescence dosimetry system for in vivo dosimetry. The stability of the system was not sufficient to satisfy commissioning requirements and therefore it has not been released into clinical service at this time.

  16. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C.G.

    2005-01-01

    Full text: The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2002). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to US personal dosimeter processing testing. The testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. This unique philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (author)

  17. 75 FR 12804 - Withdrawal of Regulatory Guide 8.6

    Science.gov (United States)

    2010-03-17

    ... ``Regulatory Guides'' in the NRC's Electronic Reading Room at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2010-0103] Withdrawal of Regulatory Guide 8.6 AGENCY: Nuclear Regulatory Commission. ACTION: Withdrawal of Regulatory Guide 8.6, ``Standard Test Procedure for Geiger-M...

  18. 75 FR 20868 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2010-04-21

    ... available through the NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc... NUCLEAR REGULATORY COMMISSION [NRC-2009-0351] Notice of Issuance of Regulatory Guide AGENCY: Nuclear Regulatory Commission. ACTION: Notice of Issuance and Availability of Regulatory Guide 1.68.2...

  19. Dosimetry optimization at COGEMA-La Hague

    International Nuclear Information System (INIS)

    Kalimbadjian, J.

    2000-01-01

    At the present time, the la Hague site strives to apply international recommendations together with national regulations concerning radiation protection, and especially the respect of limitation and optimization principles. The application of these principles is based on the implementation of a passive dosimetry and an active dosimetry. The monthly passive dosimetry is monitored by means of a photographic dosimetry film, completed with lithium fluorine thermoluminescent film badges. This personal dosimetry common to X, β, γ and neutron radiations is carried out in close relationship between the Radiation Protection Department, the Occupational Medical Department and the staff running the Plant. The application or ALARA's principle as well as that of radiation protection optimization implies to implement a complementary active dosimetry enabling to gain in real time, the personal dosimetry of each intervening person, either they be COGEMA's workers or external companies'. This active dosimetry provides with following information: This preventive dosimetry is based on the knowledge of doses integration in real time and is fitted with alarm thresholds according to the total amount of doses and dose rates. Thresholds on the dose rate are also set relatively to the radiological environment. This knowledge of doses and dose rates allows a stricter management of the works, while analyzing them according to the nature of the work, to the location and to the skills of the intervening people. This dosimetry allows to analyze and optimize doses integration according to the works nature for the whole intervening staff. The la Hague Site has developed an active personal dosimetry system, common to every intervening person, COGEMA or external companies. The DOSICARD was thus elaborated, shaped as an electronic dosimeter fitted with an alarm and a smart card. The access to controlled areas is conditioned to information given by the DOSICARD concerning medical aptitudes and

  20. Information system fur the management of a regulatory programme

    International Nuclear Information System (INIS)

    Ortiz, P.; Mrabit, K.; Miaw, S.

    1998-01-01

    A Regulatory Programme to monitor safety of activities involving radiation sources, implies the existence of a Regulatory Authority empowered by legislation to issue radiation protection regulations and to monitor compliance with those regulations. The core element of the programme is a system of notification and authorization (registration and licensing), inspection and enforcement. The efficiency of this system is largely dependent on the availability of reliable information on the inventory of radiation sources and installations, the administrative status of the facilities (authorization), prompt processing of inspection reports and follow up of regulatory actions, including monitoring deadlines. Essential data relevant to safety, such as personal dosimetry for occupationally exposed individuals, inspection findings and incident reports would provide, in addition, an insight on the overall safety of the country. A simple but comprehensive Regulatory Authority Information System (RAIS) linked to the authorization and inspection process will largely facilitate regulatory decisions and actions. A readily available and reliable information from the various regulatory activities will facilitate planning, optimization of resources, monitoring safety related data, disseminating safety information, making decisions and follow up regulatory actions including monitoring dead lines. The implementation of the system in more than 50 countries will contribute to experience exchange and harmonization of regulatory activities. (author)

  1. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed

  2. The dosimetry of ionizing radiation

    CERN Document Server

    1990-01-01

    A continuation of the treatise The Dosimetry of Ionizing Radiation, Volume III builds upon the foundations of Volumes I and II and the tradition of the preceeding treatise Radiation Dosimetry. Volume III contains three comprehensive chapters on the applications of radiation dosimetry in particular research and medical settings, a chapter on unique and useful detectors, and two chapters on Monte Carlo techniques and their applications.

  3. Secondary standard dosimetry laboratory (SSDL)

    International Nuclear Information System (INIS)

    Md Saion bin Salikin.

    1983-01-01

    A secondary Standard Dosimetry Laboratory has been established in the Tun Ismail Research Centre, Malaysia as a national laboratory for reference and standardization purposes in the field of radiation dosimetry. This article gives brief accounts on the general information, development of the facility, programmes to be carried out as well as other information on the relevant aspects of the secondary standard dosimetry laboratory. (author)

  4. Regulatory Science in Practice (Pharmaceuticals and Medical Devices Agency).

    Science.gov (United States)

    Hojo, Taisuke

    2017-01-01

    Review, safety, and relief services of the Pharmaceuticals and Medical Devices Agency are primarily focused on scientifically evaluating pharmaceuticals, medical devices, and cellular and tissue-based products referring to their quality, efficacy, and safety, which requires a variety of scientific knowledge and methods. Pharmaceutical regulation should be established based on the most advanced scientific expertise at all times. In order to evaluate products that use cutting-edge technology such as induced pluripotent stem cells and information and communication technology adequately, since fiscal year 2012 the Science Committee has been established as a platform to exchange opinions among members from top-ranking domestic and international academia and to enhance personnel exchanges through the Initiative to Facilitate Development of Innovative Drugs. In addition, the Regulatory Science Center will be established in 2018 to increase the integrity of our services for product reviews and safety measures. In particular, requiring electronic data submissions for clinical trial applications followed by an advanced approach to analysis should not only enhance the quality of reviews of individual products but should also support the development of pharmaceuticals and medical devices by providing pharmaceutical affairs consultations on research and development strategies with various guidelines based on new insights resulting from product-bridging data analysis. Moreover, a database including electronic health records with comprehensive medical information collected mainly from 10 cooperating medical institutions will be developed with the aim of developing safety measures in a more timely manner using methods of pharmacoepidemiological analysis.

  5. Dosimetry in nuclear power plants

    International Nuclear Information System (INIS)

    Lastra B, J. A.

    2008-12-01

    To control the occupationally exposed personnel dose working at the Laguna Verde nuclear power plant, two types of dosemeters are used, the thermoluminescent (TLD) which is processed monthly, and the direct reading dosemeter that is electronic and works as daily control of personal dose. In the case of the electronic dosemeters of direct reading conventional, the readings and dose automatic registers and the user identity to which he was assigned to each dosemeter was to carry out the restricted area exit. In activities where the ionizing radiation sources are not fully characterized, it is necessary to relocate the personal dosemeter or assigned auxiliary dosemeters (TLDs and electronics) to determine the dose received by the user to both whole body and in any specific area of it. In jobs more complicated are used a tele dosimetry system where the radiation protection technician can be monitoring the user dose to remote control, the data transmission is by radio. The dosimetry activities are documented in procedures that include dosemeter inventories realization, the equipment and dosemeters calibration, the dosimetry quality control and the discrepancies investigation between the direct reading and TLD systems. TLD dosimetry to have technical expertise in direct and indirect dosimetry and two technicians in TLD dosimetry; electronic dosimetry to have 4 calibration technicians. For the electronic dosemeters are based on a calibrator source of Cesium-137. TLD dosemeters to have an automatic radiator, an automatic reader which can read up to 100 TLD dosemeters per hour and a semiautomatic reader. To keep the equipment under a quality process was development a process of initial entry into service and carried out a periodic verification of the heating cycles. It also has a maintenance contract for the equipment directly with the manufacturer to ensure their proper functioning. The vision in perspective of the dosimetry services of Laguna Verde nuclear power plant

  6. Guidelines for Member States concerning radiation measurement standards and Secondary Standard Dosimetry Laboratories

    International Nuclear Information System (INIS)

    1986-01-01

    In the early nineteen-sixties an acute need developed for higher dosimetric accuracy in radiation therapy, particularly in developing countries. This need led to the establishment of a number of dosimetry laboratories around the world, specializing in the calibration of radiation therapy dosimeters. In order to co-ordinate the provision of guidance and assistance to such laboratories, the International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) set up a Network of Secondary Standard Dosimetry Laboratories (SSDLs) under their joint aegis, as described in the IAEA booklet 'SSDLs: Development and Trends' (1985). This publication includes detailed criteria for the establishment of these laboratories. The present guidelines deal with the functions and status of SSDLs, in particular with the need for recognition and support by the competent national authorities. (author)

  7. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  8. Final report for the 1st ex-vessel neutron dosimetry installations and evaluations for Kori unit 2 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 2 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 20 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 20.

  9. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Li, Nam Jin; Hong, Joon Wha

    2007-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  10. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  11. Final report for the 1st ex-vessel neutron dosimetry installation and evaluations for Kori unit 4 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 4 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 16 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 4 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 16.

  12. Expert Views on Regulatory Preparedness for Managing the Risks of Nanotechnologies

    Science.gov (United States)

    Beaudrie, Christian E. H.; Satterfield, Terre; Kandlikar, Milind; Harthorn, Barbara H.

    2013-01-01

    The potential and promise of nanotechnologies depends in large part on the ability for regulatory systems to assess and manage their benefits and risks. However, considerable uncertainty persists regarding the health and environmental implications of nanomaterials, hence the capacity for existing regulations to meet this challenge has been widely questioned. Here we draw from a survey (N=254) of US-based nano-scientists and engineers, environmental health and safety scientists, and regulatory scientists and decision-makers, to ask whether nano experts regard regulatory agencies as prepared for managing nanomaterial risks. We find that all three expert groups view regulatory agencies as unprepared. The effect is strongest for regulators themselves, and less so for scientists conducting basic, applied, or health and safety work on nanomaterials. Those who see nanotechnology risks as novel, uncertain, and difficult to assess are particularly likely to see agencies as unprepared. Trust in regulatory agencies, views of stakeholder responsibility regarding the management of risks, and socio-political values were also found to be small but significant drivers of perceived agency preparedness. These results underscore the need for new tools and methods to enable the assessment of nanomaterial risks, and to renew confidence in regulatory agencies’ ability to oversee their growing use and application in society. PMID:24244662

  13. Modern methods of personnel dosimetry

    International Nuclear Information System (INIS)

    Kraus, W.; Herrmann, D.; Kiesewetter, W.

    The physical properties of radiation detectors for personnel dosimetry are described and compared. The suitability of different types of dosimeters for operational and central monitoring of normal occupational exposure, for accident and catastrophe dosimetry and for background and space-flight dosimetry is discussed. The difficulties in interpreting the dosimeter reading with respect to the dose in individual body organs are discussed briefly. 430 literature citations (up to Spring 1966) are given

  14. Services of the Nuclear Regulatory Authority Library

    International Nuclear Information System (INIS)

    Carregado, M.A.; Wallingre, G.V.

    2011-01-01

    Full text; The main of this work is to present the services and activities of the ARN (Autoridad Regulatoria Nuclear) Library to potential users from the biological dosimetry area in the framework of the intercomparison Meeting of the Latin American Biological Dosimetry Network held in Buenos Aires from October 27-30 of 2008. It makes a short chronology of the library; the services offered to each type of users and the tasks related to technical and international cooperation with other organizations such as: the terminology Committee of IRAM (Instituto Argentino de Normalizacion y Certificacion); the input of national literature to the INIS Database of the IAEA; the retrospective digitalisation, indexing and bibliographic description of institutional publications to be submitted to the repository of the Ibero American Forum of Nuclear and Radiation Safety Regulatory Organizations and the participation in nuclear information networks. Finally it shown some relevant data from the internal statistics. (authors)

  15. Reduction of regulatory risk: a network economic approach

    OpenAIRE

    Knieps, Günter; Weiß, Hans-Jörg

    2007-01-01

    Several definitions of regulatory risk are known from the literature. From the perspective of regulatory reform it is important to differentiate between the impact of a given regulatory scheme on the firm's risk exposure and the risk arising from discretionary behavior of regulatory agencies. Whereas the conse-quences of effective regulation in principle are known and accepted, excessive regulatory discretion may cause a strong need for regulatory reform. Regulatory reform focussing on the re...

  16. 76 FR 6587 - Pennsylvania Regulatory Program

    Science.gov (United States)

    2011-02-07

    ... [PA-159-FOR; OSM 2010-0017] Pennsylvania Regulatory Program AGENCY: Office of Surface Mining... remove a required amendment to the Pennsylvania regulatory program (the ``Pennsylvania program'') under... program amendment codified in the Federal regulations, Pennsylvania has submitted information that it...

  17. Theoretical basis for dosimetry

    International Nuclear Information System (INIS)

    Carlsson, G.A.

    1985-01-01

    Radiation dosimetry is fundamental to all fields of science dealing with radiation effects and is concerned with problems which are often intricate as hinted above. A firm scientific basis is needed to face increasing demands on accurate dosimetry. This chapter is an attempt to review and to elucidate the elements for such a basis. Quantities suitable for radiation dosimetry have been defined in the unique work to coordinate radiation terminology and usage by the International Commission on Radiation Units and Measurements, ICRU. Basic definitions and terminology used in this chapter conform with the recent ''Radiation Quantities and Units, Report 33'' of the ICRU

  18. The role of the IAEA codes of practice in the radiation dosimetry dissemination chain

    International Nuclear Information System (INIS)

    Andreo, P.

    2002-01-01

    Full text: More than 30 years ago the International Atomic Energy Agency (IAEA) published on behalf of IAEA, WHO and PAHO its first Code of Practice (CoP) for radiotherapy dosimetry, TRS-110. Aimed at kV x-rays, 60 Co and 137 Cs therapy in developing countries, and based on roentgens and rads, 'old book' readers will still find interesting practical recommendations like QA procedures that include radiographs of the ionization chamber to check that the internal electrode construction has not moved. TRS-110 was also the first and only CoP with the distinction of including the name of the author in its cover, John B Massey, recognizing that IAEA acted solely as a publisher. For the following almost 20 years IAEA dosimetry activities have prioritized the development of a Network of Secondary Standard Dosimetry Laboratories (SSDLs). In addition to disseminating traceable radiation metrology standards, in some countries the SSDLs have played the important role of compensating the lack of qualified medical physicists. The balance between radiation metrology and medical physics has now shifted towards the first area and the IAEA recommends that SSDLs should not perform the duties of medical physicists except in dire situations. During this long period, there were no updates of TRS-110 or a new IAEA CoP published, even if different generations of national dosimetry protocols had emerged. The absence of IAEA recommendations favoured the arbitrary use of such national protocols, mostly issued in UK and USA, with the result that multiple protocols were used within a given country and there were no practical links between medical physics and SSDLs except for detector calibrations. The publication in 1987 of the TRS-277 Code of Practice established a quantum leap with regard to the Agency's role in harmonizing international radiotherapy dosimetry. A new generation of N K -based national protocols had emerged in the early eighties, and the authors of TRS-277 were chosen among

  19. Proceedings of the specialist meeting on personal dosimetry and area monitoring suitable for radon and daughter products

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    The programme of work of the OECD Nuclear Energy Agency includes topics relating to radiation and environmental protection matters in mining and milling operations. A first Specialist Meeting on Personal Dosimetry and Area Monitoring suitable for Radon and Daughter Products was organised in October 1976 at Elliot Lake, Canada. The proceedings were published by NEA some months later. Following an enquiry among interested persons, NEA decided to organise a new meeting on the same subject in Paris from 20th to 22nd November 1978. The meeting dealt with questions relating to personal dosimetry techniques, the monitoring of the atmosphere in mines and their neighbourhood, as well as in buildings

  20. 75 FR 21871 - Spring 2010 Regulatory Agenda

    Science.gov (United States)

    2010-04-26

    ... Review 10/00/10 Regulatory Flexibility Analysis Required: No Agency Contact: Tad Wysor, Environmental...: wysor.tad@epamail.epa.gov Tom Eagles, Environmental Protection Agency, Air and Radiation, 6103A...

  1. Course on internal dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    2004-01-01

    This documentation was distributed to the participants in the Course of Internal Dosimetry in Nuclear Medicine organised by the Nuclear Regulatory Authority (ARN) of Argentina and held in Buenos Aires, Argentina, August 9-13, 2004. The course was intended for people from IAEA Member States in the Latin American and Caribbean region, and for professionals and workers in medicine, related with the radiation protection. Spanish and English were the languages of the course. The following subjects were covered: radioprotection of the patient in nuclear medicine; injuries by ionizing radiations; MIRD methodology; radiation dose assessment in nuclear medicine; small scale and microdosimetry; bone and marrow dose modelling; medical internal dose calculations; SPECT and image reconstruction; principles of the gamma camera; scattering and attenuation correction in SPECT; tomography in nuclear medicine

  2. 75 FR 2894 - Withdrawal of Regulatory Guide 1.148

    Science.gov (United States)

    2010-01-19

    ... downloading through the NRC's public Web site under ``Regulatory Guides'' in the NRC's Electronic Reading Room at http://www.nrc.gov/reading-rm/doc-collections . Regulatory guides are also available for... NUCLEAR REGULATORY COMMISSION [NRC-2010-0013] Withdrawal of Regulatory Guide 1.148 AGENCY: Nuclear...

  3. 75 FR 70044 - Withdrawal of Regulatory Guide 1.39

    Science.gov (United States)

    2010-11-16

    ... downloading through the NRC's public Web site under ``Regulatory Guides'' in the NRC's Electronic Reading Room at http://www.nrc.gov/reading-rm/doollectionsc-c . Regulatory guides are also available for... NUCLEAR REGULATORY COMMISSION [NRC-2010-0354] Withdrawal of Regulatory Guide 1.39 AGENCY: Nuclear...

  4. 76 FR 35922 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2011-06-20

    .... Proposed Revision 1 of Regulatory Guide (RG) 8.4, ``Personnel Monitoring Device--Direct-Reading Pocket...'' at http://www.nrc.gov/reading-rm/doc-collections/ . In addition, regulatory guides are available for... NUCLEAR REGULATORY COMMISSION [NRC-2010-0148] Notice of Issuance of Regulatory Guide AGENCY...

  5. 76 FR 28102 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2011-05-13

    ..., Probabilistic Risk Assessment Branch, Division of Risk Analysis, Office of Nuclear Regulatory Research, U.S... results of risk analyses are used to help justify regulatory action. As such, the principles, process, and... NUCLEAR REGULATORY COMMISSION [NRC-2009-0385] Notice of Issuance of Regulatory Guide AGENCY...

  6. Hydropower Regulatory and Permitting Information Desktop (RAPID) Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Levine, Aaron L [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-19

    Hydropower Regulatory and Permitting Information Desktop (RAPID) Toolkit presentation from the WPTO FY14-FY16 Peer Review. The toolkit is aimed at regulatory agencies, consultants, project developers, the public, and any other party interested in learning more about the hydropower regulatory process.

  7. The IAEA/WHO network of Secondary Standard Dosimetry Laboratories. SSDL network charter

    International Nuclear Information System (INIS)

    1999-04-01

    In 1976, the International Atomic Energy Agency (IAEA) together with the World Health Organization (WHO) established a Network of Secondary Standard Dosimetry Laboratories (SSDLs), known as the IAEA/WHO SSDL Network. This Network, through SSDLs designated by Member States, provides a direct linkage of national dosimetry standards to the international measurement system of standards traceable to the Bureau International des Poids et Mesures (BIPM), and the dissemination of S.I. quantities and units through the proper calibration of field instruments by the SSDLs. The Network has proved to be of value in improving national capabilities for instrument calibration and the awareness of better accuracy and traceability. Fifty-eight countries have nominated SSDLs for membership in the Network. Unfortunately, some of these SSDLs do not yet function as full members, perhaps because of some uncertainty as to their obligations concerning the Network. Consequently, the Scientific Committee which advises the Network Secretariat has recommended that a Charter be drawn up explaining the privileges, rights and duties of members in the Network which would strengthen their links to the international measurement system. In addition to the duties of members in the Network and the benefits that full members can receive, the Charter also describes how the Network functions and the scope of the work of the SSDLs. In producing this Charter, the advisory group has drawn heavily on the IAEA publication 'Secondary Standard Dosimetry Laboratories: Development and Trends' (1985) which summarizes the origin, development, status and prospects of the IAEA/WHO SSDL Network. The various appendices are effectively up-dates of different parts of this earlier publication, and the original drafting and reviewing bodies are given due recognition. The revisions take into account the experience the Agency has gained in coordinating the activities of the Network for more than 20 years

  8. The IAEA/WHO network of Secondary Standard Dosimetry Laboratories. SSDL network charter

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-04-01

    In 1976, the International Atomic Energy Agency (IAEA) together with the World Health Organization (WHO) established a Network of Secondary Standard Dosimetry Laboratories (SSDLs), known as the IAEA/WHO SSDL Network. This Network, through SSDLs designated by Member States, provides a direct linkage of national dosimetry standards to the international measurement system of standards traceable to the Bureau International des Poids et Mesures (BIPM), and the dissemination of S.I. quantities and units through the proper calibration of field instruments by the SSDLs. The Network has proved to be of value in improving national capabilities for instrument calibration and the awareness of better accuracy and traceability. Fifty-eight countries have nominated SSDLs for membership in the Network. Unfortunately, some of these SSDLs do not yet function as full members, perhaps because of some uncertainty as to their obligations concerning the Network. Consequently, the Scientific Committee which advises the Network Secretariat has recommended that a Charter be drawn up explaining the privileges, rights and duties of members in the Network which would strengthen their links to the international measurement system. In addition to the duties of members in the Network and the benefits that full members can receive, the Charter also describes how the Network functions and the scope of the work of the SSDLs. In producing this Charter, the advisory group has drawn heavily on the IAEA publication 'Secondary Standard Dosimetry Laboratories: Development and Trends' (1985) which summarizes the origin, development, status and prospects of the IAEA/WHO SSDL Network. The various appendices are effectively up-dates of different parts of this earlier publication, and the original drafting and reviewing bodies are given due recognition. The revisions take into account the experience the Agency has gained in coordinating the activities of the Network for more than 20 years.

  9. GENERIC DRUG IN GLOBAL MARKET AND REGULATORY ENVIRONMENT

    OpenAIRE

    Pankaj Kumar*, Bharti Mangla2, Satbir Singh, Arapna Rana

    2017-01-01

    Different regulatory authorities regulate the drug development in various countries of the world. Various Regulatory authority for generic drug application Food and Drug Administration (FDA), European Medicines Agency (EMA), Pharmaceutical and Medical Devices Agency (PMDA), Health Product and Food Branch (HPFB) Central Drug Standard of Organization (CDSO). Generic manufacturers may file an abbreviated New Drug Application (ANDA) that incorporates the safety/effectiveness data submitted by ori...

  10. 78 FR 28244 - Agency Information Collection Activities; Proposed Collection; Comment Request

    Science.gov (United States)

    2013-05-14

    ... Licensing of Production and Utilization Facilities,'' specifies technical information and data to be... NUCLEAR REGULATORY COMMISSION [Docket No. NRC-2013-0085] Agency Information Collection Activities; Proposed Collection; Comment Request AGENCY: Nuclear Regulatory Commission. ACTION: Notice of pending NRC...

  11. Personal dosimetry in Kazakhstan

    International Nuclear Information System (INIS)

    Khvoshnyanskaya, I.R.; Vdovichenko, V.G.; Lozbin, A.Yu.

    2003-01-01

    KATEP-AE Radiation Laboratory is the first organization in Kazakhstan officially licensed by the Kazakhstan Atomic Energy Committee to provide individual dosimetry services. The Laboratory was established according to the international standards. Nowadays it is the largest company providing personal dosimetry services in the Republic of Kazakhstan. (author)

  12. History of personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C. G.

    2007-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2001). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Dept. of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Dept. of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonisation to US personal dosemeter processing testing. Since there is no type testing program in the US for personal dosemeters, the testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing. This philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (authors)

  13. Status of neutron dosimetry cross sections

    International Nuclear Information System (INIS)

    Griffin, P.J.; Kelly, J.G.

    1992-01-01

    Several new cross section libraries, such as ENDF/B-VI(release 2), IRDF-90,JEF-2.2, and JENDL-3 Dosimetry, have recently been made available to the dosimetry community. the Sandia National Laboratories (SNL) Radiation Metrology Laboratory (RML) has worked with these libraries since pre-release versions were available. this paper summarizes the results of the intercomparison and testing of dosimetry cross sections. As a result of this analysis, a compendium of the best dosimetry cross sections was assembled from the available libraries for use within the SNL RML. this library, referred to as the SNLRML Library, contains 66 general dosimetry sensors and 3 special dosimeters unique to the RML sensor inventory. The SNLRML cross sections have been put into a format compatible with commonly used spectrum determination codes

  14. Environmental Protection Agency Semiannual Regulatory Agenda

    Science.gov (United States)

    2010-12-20

    ... of the economy, productivity, competition, jobs, the environment, public health or safety, or State... Steve Fruh, Environmental Protection Agency, Air and Radiation, 1200 Pennsylvania Ave, NW, Washington, DC 20460 Phone: 919 541-2837 Fax: 919 541-4991 Email: fruh.steve@epamail.epa.gov RIN: 2060-AP69...

  15. Activities developed by the biological dosimetry laboratory of the Autoridad Regulatoria Nuclear - ARN of Argentina

    International Nuclear Information System (INIS)

    Radl, A.; Sapienza, C.E.; Taja, M.R.; Bubniak, R.; Deminge, M.; Di Giorgio, M.

    2013-01-01

    Biological dosimetry (DB) allows to estimate doses absorbed in individuals exposed to ionizing radiation through the quantification of stable and unstable chromosome aberrations (SCA and UCA). The frequency of these aberrations is referred to a calibration dose response curve (in vitro) to determine the doses of the individual to the whole body. The DB is a necessary support for programs of national radiation protection and response systems in nuclear or radiological emergencies in the event of accidental or incidental, single overexposure or large scale. In this context the Laboratory of Dosimetry Biological (LDB) of the Authority Regulatory Nuclear (ARN) Argentina develops and applies different dosimeters cytogenetic from four decades ago. These dosimeters provide a fact more within the whole of the information necessary for an accidental, complementing the physical and clinical dosimetry exposure assessment. The most widely used in the DB biodosimetric method is the quantification of SCA (dicentrics and rings Central) from a sample of venous blood. The LDB is accredited for the trial, under rules IRAM 301: 2005 (ISO / IEC 17025: 2005) and ISO 19238:2004. Test applies to the immediate dosimetry evaluation of acute exposures, all or a large part of the body in the range 0,1-5 Gy. In this context the LDB is part of the Latin American network of DB (LBDNet), BioDoseNet-who and response system in radiological emergencies and nuclear IAEA-RANET, being enabled to summon the LBDNet if necessary

  16. MO-B-BRB-00: Three Dimensional Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  17. Dosimetry and shielding

    International Nuclear Information System (INIS)

    Farinelli, U.

    1977-01-01

    Today, reactor dosimetry and shielding have wide areas of overlap as concerns both problems and methods. Increased interchange of results and know-how would benefit both. The areas of common interest include calculational methods, sensitivity studies, theoretical and experimental benchmarks, cross sections and other nuclear data, multigroup libraries and procedures for their adjustment, experimental techniques and damage functions. This paper reviews the state-of-the-art and the latest development in each of these areas as far as shielding is concerned, and suggests a number of interactions that could be profitable for reactor dosimetry. Among them, re-evaluation of the potentialities of calculational methods (in view of the recent developments) in predicting radiation environments of interest; the application of sensitivity analysis to dosimetry problems; a common effort in the field of theoretical benchmarks; the use of the shielding one-material propagation experiments as reference spectra for detector cross sections; common standardization of the detector nuclear data used in both fields; the setting up of a common (or compatible) multigroup structure and library applicable to shielding, dosimetry and core physics; the exchange of information and experience in the fields of cross section errors, correlations and adjustment; and the intercomparison of experimental techniques

  18. The Latin American Biological Dosimetry Network (LBDNet)

    International Nuclear Information System (INIS)

    Garcia, O.; Lamadrid, A.I.; Gonzalez, J.E.; Romero, I.; Mandina, T.; Di Giorgio, M.; Radl, A.; Taja, M.R.; Sapienza, C.E.; Deminge, M.M.; Fernandez Rearte, J.; Stuck Oliveira, M.; Valdivia, P.; Guerrero-Carbajal, C.; Arceo Maldonado, C.; Cortina Ramirez, G.E.; Espinoza, M.; Martinez-Lopez, W.; Di Tomasso, M.

    2016-01-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. (authors)

  19. Internal dosimetry, past and future

    International Nuclear Information System (INIS)

    Johnson, J.R.

    1989-03-01

    This paper is a review of the progress in the dosimetry of internally deposited radionuclides (internal dosimetry) since World War II. Previous to that, only naturally occurring radionuclides were available and only a limited number of studies of biokinetics and dosimetry were done. The main radionuclides studied were 226 Ra, 228 Ra, and 224 Ra but natural uranium was also studied mainly because of its toxic effect as a heavy metal, and not because it was radioactive. The effects of 226 Ra in bone, mainly from the radium dial painters, also formed the only bases for the radiotoxicity of radionuclides in bone for many years, and it is still, along with 224 Ra, the main source of information on the effects of alpha emitters in bone. The publications of the International Commission on Radiological Protection that have an impact on internal dosimetry are used as mileposts for this review. These series of publications, more than any other, represent a broad consensus of opinion within the radiation protection community at the time of their publication, and have formed the bases for radiation protection practice throughout the world. This review is not meant to be exhaustive; it is meant to be a personnel view of the evolution of internal dosimetry, and to present the author's opinion of what the future directions in internal dosimetry will be. 39 refs., 2 tabs

  20. Individual neutron dosimetry

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  1. Environmental Regulatory Update Table, December 1989

    International Nuclear Information System (INIS)

    Houlbert, L.M.; Langston, M.E.; Nikbakht, A.; Salk, M.S.

    1990-01-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action

  2. Environmental regulatory update table, March 1989

    International Nuclear Information System (INIS)

    Houlberg, L.; Langston, M.E.; Nikbakht, A.; Salk, M.S.

    1989-04-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action

  3. Environmental Regulatory Update Table, April 1989

    International Nuclear Information System (INIS)

    Houlberg, L.; Langston, M.E.; Nikbakht, A.; Salk, M.S.

    1989-05-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action

  4. Environmental Regulatory Update Table, December 1991

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.

    1992-01-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  5. Environmental Regulatory Update Table, August 1990

    International Nuclear Information System (INIS)

    Houlberg, L.M.; Nikbakht, A.; Salk, M.S.

    1990-09-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action

  6. Environmental Regulatory Update Table, October 1991

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.

    1991-11-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  7. Environmental Regulatory Update Table, November 1991

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.

    1991-12-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  8. Environmental Regulatory Update Table, September 1991

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.

    1991-10-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  9. Standardization of the calibration of brachytherapy sources at the IAEA dosimetry laboratory

    International Nuclear Information System (INIS)

    Shanta, A.; Andreo, P.

    1996-01-01

    A new service to SSDLs has been initiated at the IAEA Dosimetry Laboratory for providing calibrations of well-type ionisation chambers, used in brachytherapy applications, which are traceable to the International Measurement System. Considering that the most common radionuclide used in the developing countries is 137 Cs, two such sources of the type used for gynaecological intracavitary applications have been purchased by the Agency and calibrated at the National Institute of Standards and Technology (NIST), USA. These 137 Cs reference sources together with a well-type ionization chamber constitute the IAEA brachytherapy dosimetry standard. Based on the recommendations by a group of experts, a method has been developed for transferring calibrations to SSDLs which is described in this paper. The method is based on the acquisition by the SSDLs of sources and equipment similar to those at the IAEA. The well-type chamber is to be calibrated at the IAEA Dosimetry Laboratory, and this will be used at the SSDL to calibrate its own reference sources. These sources can in turn by used to calibrate well-type chambers from hospital users and to calibrate other type of sources by performing measurements in air. In order to standardize the procedures for the two methods and to provide guidance to the SSDLs, measurements have been carried out at the IAEA Dosimetry Laboratory. The reproducibility of the two type of measurements has been found to be better than 0.5%, and the uncertainty of calibrations estimated to be less than 1.5% (one standard deviation). (author). 8 refs, 8 figs, 2 tabs

  10. Advantages and disadvantages of luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Olko, Pawel, E-mail: Pawel.Olko@ifj.edu.p [Institute of Nuclear Physics Polish Academy of Science (IFJ PAN), Krakow (Poland)

    2010-03-15

    Owing to their excellent dosimetric properties, luminescence detectors of ionizing radiation are now extensively applied in individual dosimetry services. The most frequently used personal dosemeters are based on Optically Stimulated Luminescence (OSL), radiophotoluminescence (RPL) or thermoluminescence (TL). Luminescence detectors have also found several applications in clinical dosimetry, especially around new radiation modalities in radiotherapy, such as Intensity Modulated Radiotherapy (IMRT) or ion beam radiotherapy. Requirements of luminescence detectors applied in individual and clinical dosimetry and some recent developments in luminescence of detectors and techniques leading to significant improvements of the functionality and accuracy of dosimetry systems are reviewed and discussed.

  11. Introduction to the Unified Agenda of Federal Regulatory and Deregulatory Actions

    Science.gov (United States)

    2010-04-26

    ... Regulatory Commission Federal Housing Finance Agency Federal Maritime Commission Federal Mediation and... that the Regulatory Flexibility Act may require a Regulatory Flexibility Analysis, actions selected for.... Regulatory Flexibility Analysis Required -- whether an analysis is required by the Regulatory Flexibility Act...

  12. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  13. 75 FR 9444 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Science.gov (United States)

    2010-03-02

    ... Utilization Facilities,'' specifies technical information and data to be provided to the NRC or maintained by... NUCLEAR REGULATORY COMMISSION [Docket No. NRC-2010-0063] Agency Information Collection Activities: Proposed Collection; Comment Request AGENCY: U.S. Nuclear Regulatory Commission (NRC). ACTION: Notice of...

  14. Advances in Canadian regulatory practice

    International Nuclear Information System (INIS)

    Waddington, J.G.

    1993-03-01

    The new General Amendments to the Regulations, new recommendations on dose limits, developments in techniques and safety thinking, and aging of plant are all contributing to the need for a significant number of new regulatory document on a wide range of topics. this paper highlights a number of initiatives taken in response to these pressures, giving a brief background to the initiative and, where possible, outlining some of the ideas in the document licensing guides on new dose limits, dosimetry, safety analysis, reliability, fault tree analysis, reporting requirements, human factors, software, the ALARA principle, backfitting and the licensing process. (Author) 29 refs., fig., 4 tabs

  15. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  16. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2009-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry. Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  17. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2008-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry . Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  18. Neutron personal dosimetry: state-of-art

    International Nuclear Information System (INIS)

    Spurný, František

    2005-03-01

    State-of-art of the personal neutron dosimetry is presented, analysed and discussed. Particular attention is devoted to the problems of this type of the dosimetry of external exposure for radiation fields at nuclear power plants. A review of general problems of neutron dosimetry is given and the active individual dosimetry methods available and/or in the stage of development are briefly reviewed. Main attention is devoted to the analysis of the methods available for passive individual neutron dosimetry. The characteristics of these dosemeters were studied and are compared: their energy response functions, detection thresholds and the highest detection limits, the linearity of response, the influence of environmental factors, etc. Particular attention is devoted to their behavior in reactor neutron fields. It is concluded that the choice of the neutron personal dosemeter depends largely on the conditions in which the instrument should be used (neutron spectrum, the level of exposure and the exposure rate, etc.). The results obtained with some of these dosemeters during international intercomparisons are also presented. Particular attention is paid to the personal neutron dosimeter developed and routinely used by National Personal Dosimetry Service Ltd. in the Czech Republic. (author)

  19. Environmental Regulatory Update Table, August 1991

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M., Hawkins, G.T.; Salk, M.S.

    1991-09-01

    This Environmental Regulatory Update Table (August 1991) provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  20. Environmental regulatory update table, July 1991

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.

    1991-08-01

    This Environmental Regulatory Update Table (July 1991) provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  1. Internal dosimetry technical basis manual

    International Nuclear Information System (INIS)

    1990-01-01

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs

  2. Internal dosimetry technical basis manual

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-20

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.

  3. Dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Desrosiers, M.F.

    1995-01-01

    Dosimetry serves important functions in radiation processing, where large absorbed doses and dose rates from photon and electron sources have to be measured with reasonable accuracy. Proven dosimetry systems are widely used to perform radiation measurements in development of new processes, validation, qualification and verification (quality control) of established processes and archival documentation of day-to-day and plant-to-plant processing uniformity. Proper calibration and traceability of routine dosimetry systems to standards are crucial to the success of many large-volume radiation processes. Recent innovations and advances in performance of systems that enhance radiation measurement assurance and process diagnostics include dose-mapping media (new radiochromic film and solutions), optical waveguide systems for food irradiation, solid-state devices for real-time and passive dosimetry over wide dose-rate and dose ranges, and improved analytical instruments and data acquisition. (author)

  4. 76 FR 64043 - Iowa Regulatory Program

    Science.gov (United States)

    2011-10-17

    ...) Requirements for permits for special categories of mining. 27--40.41(207) Permanent regulatory program--small... DEPARTMENT OF THE INTERIOR Office of Surface Mining Reclamation and Enforcement 30 CFR Part 915 [Docket No. IA-016-FOR; Docket ID: OSM-2011-0014] Iowa Regulatory Program AGENCY: Office of Surface Mining...

  5. Individual dosimetry of workers and patients: implementation and perspectives; La dosimetrie individuelle des travailleurs et de patients: mise en oeuvre et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E

    2008-07-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  6. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  7. In vivo dosimetry in radiation therapy in Sweden; In vivo-dosimetri inom straalbehandling i Sverige

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Jacob; Blomquist, Michael (Norrlands universitetssjukhus, Umeaa (Sweden))

    2010-07-15

    A prerequisite for achieving high radiation safety for patients receiving external beam radiation therapy is that the hospitals have a quality assurance program. The program should include include monitoring of the radiation dose given to the patient. Control measurements are performed both at the system level and at the individual level. Control measurement is normally performed using in vivo dosimetry, e.g. a method to measure the radiation dose at the individual level during the actual radiation treatment time. In vivo dosimetry has proven to be an important tool to detect and prevent serious errors in patient treatment. The purpose of this research project was to identify the extent to which vivo dosimetry is used and the methods available for this at Swedish radiation therapy clinics. The authority also wanted to get an overall picture of how hospitals manage results of in vivo dosimetry, and how clinics control radiation dose when using modern treatment techniques. The report reflects the situation in Swedish radiotherapy clinics 2007. The report shows that all hospitals use some form of in vivo dosimetry. The instruments used are mainly diodes and termoluminiscence dosimeters

  8. Environmental Regulatory Update Table, January/February 1995

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Bock, R.E.; Mayer, S.J.; Salk, M.S.

    1995-03-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives impacting environmental, health, and safety management responsibilities. the table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  9. Environmental Regulatory Update Table, January/February 1995

    International Nuclear Information System (INIS)

    Houlberg, L.M.; Hawkins, G.T.; Bock, R.E.; Mayer, S.J.; Salk, M.S.

    1995-03-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives impacting environmental, health, and safety management responsibilities. the table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action

  10. A broad-group cross-section library based on ENDF/B-VII.0 for fast neutron dosimetry Applications

    Energy Technology Data Exchange (ETDEWEB)

    Alpan, F.A. [Westinghouse Electric Company, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2011-07-01

    A new ENDF/B-VII.0-based coupled 44-neutron, 20-gamma-ray-group cross-section library was developed to investigate the latest evaluated nuclear data file (ENDF) ,in comparison to ENDF/B-VI.3 used in BUGLE-96, as well as to generate an objective-specific library. The objectives selected for this work consisted of dosimetry calculations for in-vessel and ex-vessel reactor locations, iron atom displacement calculations for reactor internals and pressure vessel, and {sup 58}Ni(n,{gamma}) calculation that is important for gas generation in the baffle plate. The new library was generated based on the contribution and point-wise cross-section-driven (CPXSD) methodology and was applied to one of the most widely used benchmarks, the Oak Ridge National Laboratory Pool Critical Assembly benchmark problem. In addition to the new library, BUGLE-96 and an ENDF/B-VII.0-based coupled 47-neutron, 20-gamma-ray-group cross-section library was generated and used with both SNLRML and IRDF dosimetry cross sections to compute reaction rates. All reaction rates computed by the multigroup libraries are within {+-} 20 % of measurement data and meet the U. S. Nuclear Regulatory Commission acceptance criterion for reactor vessel neutron exposure evaluations specified in Regulatory Guide 1.190. (authors)

  11. The Latin American Biological Dosimetry Network (LBDNet).

    Science.gov (United States)

    García, O; Di Giorgio, M; Radl, A; Taja, M R; Sapienza, C E; Deminge, M M; Fernández Rearte, J; Stuck Oliveira, M; Valdivia, P; Lamadrid, A I; González, J E; Romero, I; Mandina, T; Guerrero-Carbajal, C; ArceoMaldonado, C; Cortina Ramírez, G E; Espinoza, M; Martínez-López, W; Di Tomasso, M

    2016-09-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Regulatory Support of Treatment of Savannah River Site Purex Waste

    International Nuclear Information System (INIS)

    Reid, L.T.

    2009-01-01

    This paper describes the support given by federal and state regulatory agencies to Savannah River Site (SRS) during the treatment of an organic liquid mixed waste from the Plutonium Extraction (Purex) process. The support from these agencies allowed (SRS) to overcome several technical and regulatory barriers and treat the Purex waste such that it met LDR treatment standards. (authors)

  13. Research and innovation in radiation dosimetry

    International Nuclear Information System (INIS)

    Delgado, A.

    1999-01-01

    In this article some relevant lines of research in radiation dosimetry are presented. In some of them innovative approaches have been recently proposed in recent years. In others innovation is still to come as it is necessary in view of the insufficiency of the actual methods and techniques. mention is made to Thermoluminescence Dosimetry an to the improvement produced by new computational methods for the analysis of the usually complex TL signals. A solid state dosimetric technique recently proposed, Optically Stimulated Luminescence, OSL, is briefly presented. This technique promises advantages over TLD for personal and environmental dosimetry. The necessity of improving the measurement characteristics of neutron personal dosemeters is commented, making reference to some very recent developments. The situation of the dosimetry in connection with radiobiology research is overviewed, commenting the controversy on the adequacy and utility of the quality absorbed dose for these activities. Finally the special problematic of internal dosimetry is discussed. (Author) 25 refs

  14. Dosimetry control for radiation processing - basic requirements and standards

    International Nuclear Information System (INIS)

    Ivanova, M.; Tsrunchev, Ts.

    2004-01-01

    A brief review of the basic international codes and standards for dosimetry control for radiation processing (high doses dosimetry), setting up a dosimetry control for radiation processing and metrology control of the dosimetry system is made. The present state of dosimetry control for food processing and the Bulgarian long experience in food irradiation (three irradiation facilities are operational at these moment) are presented. The absence of neither national standard for high doses nor accredited laboratory for calibration and audit of radiation processing dosimetry systems is also discussed

  15. Dosimetry in dentistry.

    Science.gov (United States)

    Asha, M L; Chatterjee, Ingita; Patil, Preeti; Naveen, S

    2015-01-01

    The purpose of this paper was to review various dosimeters used in dentistry and the cumulative results of various studies done with various dosimeters. Several relevant PubMed indexed articles from 1999 to 2013 were electronically searched by typing "dosimeters", "dosimeters in dentistry", "properties of dosimeters", "thermoluminescent and optically stimulated dosimeters", "recent advancements in dosimetry in dentistry." The searches were limited to articles in English to prepare a concise review on dental dosimetry. Titles and abstracts were screened, and articles that fulfilled the criteria of use of dosimeters in dental applications were selected for a full-text reading. Article was divided into four groups: (1) Biological effects of radiation, (2) properties of dosimeters, (3) types of dosimeters and (4) results of various studies using different dosimeters. The present review on dosimetry based on various studies done with dosimeters revealed that, with the advent of radiographic technique the effective dose delivered is low. Therefore, selection of radiological technique plays an important role in dental dose delivery.

  16. Public Perceptions of Regulatory Costs, Their Uncertainty and Interindividual Distribution.

    Science.gov (United States)

    Johnson, Branden B; Finkel, Adam M

    2016-06-01

    Public perceptions of both risks and regulatory costs shape rational regulatory choices. Despite decades of risk perception studies, this article is the first on regulatory cost perceptions. A survey of 744 U.S. residents probed: (1) How knowledgeable are laypeople about regulatory costs incurred to reduce risks? (2) Do laypeople see official estimates of cost and benefit (lives saved) as accurate? (3) (How) do preferences for hypothetical regulations change when mean-preserving spreads of uncertainty replace certain cost or benefit? and (4) (How) do preferences change when unequal interindividual distributions of hypothetical regulatory costs replace equal distributions? Respondents overestimated costs of regulatory compliance, while assuming agencies underestimate costs. Most assumed agency estimates of benefits are accurate; a third believed both cost and benefit estimates are accurate. Cost and benefit estimates presented without uncertainty were slightly preferred to those surrounded by "narrow uncertainty" (a range of costs or lives entirely within a personally-calibrated zone without clear acceptance or rejection of tradeoffs). Certain estimates were more preferred than "wide uncertainty" (a range of agency estimates extending beyond these personal bounds, thus posing a gamble between favored and unacceptable tradeoffs), particularly for costs as opposed to benefits (but even for costs a quarter of respondents preferred wide uncertainty to certainty). Agency-acknowledged uncertainty in general elicited mixed judgments of honesty and trustworthiness. People preferred egalitarian distributions of regulatory costs, despite skewed actual cost distributions, and preferred progressive cost distributions (the rich pay a greater than proportional share) to regressive ones. Efficient and socially responsive regulations require disclosure of much more information about regulatory costs and risks. © 2016 Society for Risk Analysis.

  17. How are things going. Obtaining feedback in a regulatory environment

    International Nuclear Information System (INIS)

    McGuire, J.V.; Walsh, M.E.; Boegel, A.J.; Morisseau, D.S.; Persendky, J.J.

    1984-08-01

    This study tested two procedures to gather feedback for a federal agency about its regulatory actions and its licensees' practices. The procedures, a workshop and a mailed survey, targeted a data source new to the agency. Results to date find the feedback workshop useful and the new data source cooperative and valuable. Participation in the workshops is surprising, given their historical backdrop, structure, and psychological literatures. These findings suggest that agencies may be ignoring important data sources for ill-informed reasons. Also, the findings suggest a possible need to restructure existing channels of communication between a regulatory agency and its licensees

  18. Experts Complete IAEA Follow-up Review of Australia's Nuclear Regulatory Authority

    International Nuclear Information System (INIS)

    2011-01-01

    Full text: Nuclear and radiation safety experts today concluded an eight-day mission to review the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), the country's nuclear regulator. At the request of the Australian Government, the International Atomic Energy Agency (IAEA) assembled a peer-review team of five regulatory experts from as many nations and three IAEA staff members to conduct a follow-up assessment of an Integrated Regulatory Review Service (IRRS) mission conducted in 2007. This follow-up IRRS mission examined ARPANSA's progress in acting upon the recommendations and suggestions made during the 2007 IRRS mission and reviewed the areas of significant regulatory changes since that review. Both reviews covered safety regulatory aspects of all facilities and activities regulated by ARPANSA. IRRS team leader Kaare Ulbak, Chief Advisor of Denmark's National Institute of Radiation Protection, said: ''ARPANSA should be commended for the significant amount of efforts in addressing all the findings identified in the 2007 mission and for inviting this follow-up review.'' The review team found that ARPANSA has made significant progress toward improving its regulatory activities, as most of the findings identified in the 2007 report have been effectively addressed and therefore can be considered closed. Complementing the ARPANSA strengths identified during the 2007 mission, the 2011 IRRS team noted the following strengths: Response to the Tepco Fukushima Dai-ichi accident; High level of in-house technical expertise in radiation safety; Recognition of the need and willingness to re-organize ARPANSA; Timely development of the national sealed source register in good coordination with other relevant organizations; and Creation of the Australian clinical dosimetry service and the national dose reference levels database. The 2011 IRRS team also made recommendations and suggestions to further strengthen ARPANSA's regulatory system, including: Making full

  19. Results of the dosimetry intercomparison

    International Nuclear Information System (INIS)

    Dure, Elsa S.

    2000-07-01

    The appropriate way to verify the accuracy of the results of dose reported by the laboratories that offer lend personal dosimetry service is in the periodic participation of round of intercomparison dosimetry, undertaken by laboratories whose standards are trace (Secondary Laboratory). The Laboratory of External Personal Dosimetry of the CNEA-PY has participated in three rounds of intercomparison. The first two were organized in the framework of the Model Project RLA/9/030 RADIOLOGICAL WASTE SECURITY, and the irradiations were carried out in the Laboratory of Regional Calibration of the Center of Nuclear Technology Development, Belo Horizonte-Brazil (1998) and in the National Laboratory of Metrology of the ionizing radiations of the Institute of Radioprotection and Dosimetry, Rio de Janeiro-Brazil (1999). The third was organized by the IAEA and the irradiations were made in the Physikalisch-Technische Bundesanstalt PTB, Braunschweig - Federal Republic of Germany (1999-2000) [es

  20. 76 FR 20052 - Notice of Issuance of Regulatory Guide

    Science.gov (United States)

    2011-04-11

    ... the NRC's public Web site under ``Regulatory Guides'' at http://www.nrc.gov/reading-rm/doc-collections... NUCLEAR REGULATORY COMMISSION [NRC-2010-0187] Notice of Issuance of Regulatory Guide AGENCY... Guide 1.149, ``Nuclear Power Plant Simulation Facilities for Use in Operator Training, License...

  1. Dosimetry standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  2. Dosimetry in diagnostic and interventional radiology - ICRU and IAEA activities

    International Nuclear Information System (INIS)

    Zoetelief, J.; Pernicka, F.

    2002-01-01

    , the entrance surface air kerma (ESAK), the entrance air kerma, the air kerma, the entrance surface dose (ESD), the entrance skin dose (ESD) and the integral skin dose. Different names are used for the same quantity, e.g. entrance surface air kerma, air kerma and entrance air kerma. The same abbreviation ESD is used for both entrance surface dose (absorbed dose most likely expressed in air) and entrance skin dose (absorbed dose most likely expressed in skin tissue). Similar problems exist for dosimetry in mammography and CT. The present situation in dosimetry for medical x-ray imaging clearly indicates the need for dose quantities recommended for the different applications and the need for a harmonised system for names, symbols and units. This has been recognised by the International Commission on Radiation Units and Measurements (ICRU) and resulted in the establishment of an ICRU Report Committee on patient dosimetry in medical imaging. The report proposes a harmonised system of quantities and units for patient dosimetry in medical imaging using x-rays. New symbols are proposed for various quantities. General information is provided on measurement methods, including various aspects of calibration of dosemeters, and methods of determining organ and tissue doses. The International Atomic Energy Agency (IAEA) is developing an international code of practice for dosimetry in x-ray diagnostic radiology. The main objective of the code of practice is to help to achieve and maintain a high level of quality in dosimetry, to improve the implementation of traceable standards at the national level and to ensure control of radiation dose in x-ray medical imaging worldwide. Compared to the ICRU, the IAEA activities put more emphasis on the practical aspects of establishment of proper calibration facilities, e.g. at the Secondary Standard Dosimetry Laboratories, and provide more detailed recommendations for clinical dosimetry. Co-ordination between ICRU and IAEA activities is

  3. Individual dosimetry of workers and patients: implementation and perspectives

    International Nuclear Information System (INIS)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E.

    2008-01-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  4. Delegação e controle político das agências reguladoras no Brasil Delegation and political control of the regulatory agencies in Brazil

    Directory of Open Access Journals (Sweden)

    Fernanda Meirelles

    2006-08-01

    Full Text Available A partir de um esforço de sistematização dos mecanismos de controle político previstos no modelo institucional originalmente concebido para as agências reguladoras, este artigo avalia os mecanismos de controle político presentes no arcabouço institucional das agências reguladoras independentes (ARIs brasileiras e analisa as alterações relacionadas ao controle político introduzidas pelo projeto de lei encaminhado pelo governo ao Congresso em 12 de abril de 2004. Após contextualizar o debate sobre o controle político das ARIs no Brasil, o artigo discute as relações entre delegação e responsabilização. Em seguida, na busca de um parâmetro para avaliar o modelo brasileiro de agências reguladoras (ARs, identifica os instrumentos de controle político utilizados na experiência americana. Finalmente, avalia a realidade institucional atual das ARIs brasileiras e comenta as contribuições do recente projeto de lei em relação ao controle político das agências.This article systematizes the political control mechanisms provided by the institutional model originally conceived for the regulatory agencies in order to assess the political control mechanisms in the institutional framework of the Brazilian independent regulatory agencies (IRAs and analyze the political control changes introduced by the law proposed by the government to Congress in April 12, 2004. After putting into context the debate on political control over the Brazilian IRAs, the article discusses the relationship between delegation and accountability. Then, so as to find a parameter for assessing the Brazilian regulatory agency model, it identifies the political control mechanisms used by the American experience. Finally, it assesses the current institutional situation of the Brazilian IRAs and comments on the contribution of the recent law proposal in relation to agency political control.

  5. The dosimetry programme of the IAEA

    International Nuclear Information System (INIS)

    1987-01-01

    Describes the activities of the IAEA's Dosimetry Laboratory which provides calibration and comparison services for secondary standard dosimetry laboratories (SSDLs) of Member States. In addition, a joint IAEA/WHO postal dosimetry service has been established for radiotherapy centers. The International Measurement System and the calibration ''chain'' from measurement standard instruments of the International Bureau of Weights and Measurements (BIPM) through the primary and secondary standards to the dosimeters of the users are presented as well

  6. Retrospective assessment of personnel neutron dosimetry for workers at the Hanford Site

    International Nuclear Information System (INIS)

    Fix, J.J.; Wilson, R.H.; Baumgartner, W.B.

    1996-09-01

    This report was prepared to examine the specific issue of the potential for unrecorded neutron dose for Hanford workers, particularly in comparison with the recorded whole body (neutron plus photon) dose. During the past several years, historical personnel dosimetry practices at Hanford have been documented in several technical reports. This documentation provides a detailed history of the technology, radiation fields, and administrative practices used to measure and record dose for Hanford workers. Importantly, documentation has been prepared by personnel whose collective experience spans nearly the entire history of Hanford operations beginning in the mid-1940s. Evaluations of selected Hanford radiation dose records have been conducted along with statistical profiles of the recorded dose data. The history of Hanford personnel dosimetry is complex, spanning substantial evolution in radiation protection technology, concepts, and standards. Epidemiologic assessments of Hanford worker mortality and radiation dose data were initiated in the early 1960s. In recent years, Hanford data have been included in combined analyses of worker cohorts from several Department of Energy (DOE) sites and from several countries through the International Agency for Research on Cancer (IARC). Hanford data have also been included in the DOE Comprehensive Epidemiologic Data Resource (CEDR). In the analysis of Hanford, and other site data, the question of comparability of recorded dose through time and across the respective sites has arisen. DOE formed a dosimetry working group composed of dosimetrists and epidemiologists to evaluate data and documentation requirements of CEDR. This working group included in its recommendations the high priority for documentation of site-specific radiation dosimetry practices used to measure and record worker dose by the respective DOE sites

  7. Hematological dosimetry

    International Nuclear Information System (INIS)

    Fluery-Herard, A.

    1991-01-01

    The principles of hematological dosimetry after acute or protracted whole-body irradiation are reviewed. In both cases, over-exposure is never homogeneous and the clinical consequences, viz medullary aplasia, are directly associated with the mean absorbed dose and the seriousness and location of the overexposure. The main hematological data required to assess the seriousness of exposure are the following: repeated blood analysis, blood precursor cultures, as indicators of whole-body exposure; bone marrow puncture, medullary precursor cultures and medullary scintigraphy as indicators of the importance of a local over-exposure and capacity for spontaneous repair. These paraclinical investigations, which are essential for diagnosis and dosimetry, are also used for surveillance and for the main therapeutic issues [fr

  8. Through the regulatory hoop

    International Nuclear Information System (INIS)

    Kirner, N.P.

    1985-01-01

    There are many regulatory hoops through which waste generators, brokers, and disposal site operators must jump to dispose of waste safely. As the proposed exclusionary date of January 1, 1986, approaches, these regulatory hoops have the distinct possibility of multiplying or at least changing shape. The state of Washington, in its role as an Agreement State with the US Nuclear Regulatory Commission, licenses and inspects the commercial operator of the Northwest Compact's low-level radioactive waste disposal site on the Hanford Reservation. Washington has received as much as 53%, or 1.4 million cubic feet per year, of the nation's total volume of waste disposed. To control such a large volume of waste, a regulatory program involving six agencies has developed over the years in Washington

  9. Environmental Regulatory Update Table, January--February 1993

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1993-03-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  10. Environmental Regulatory Update Table, November--December 1993

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1994-01-01

    The Environmental Regulatory Update Table provides information on regulatory of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  11. Environmental regulatory update table November--December 1994

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Bock, R.E.; Mayer, S.J.; Salk, M.S.

    1995-01-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  12. Environmental Regulatory Update Table, May--June 1994

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Bock, R.E.; Salk, M.S.

    1994-07-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bimonthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  13. Environmental Regulatory Update Table, May/June 1993

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1993-07-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bimonthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  14. Environmental regulatory update table, March--April 1994

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Bock, R.E. [Oak Ridge National Lab., TN (United States). Health Sciences Research Div.; Salk, M.S. [Oak Ridge National Lab., TN (United States). Environmental Sciences Div.

    1994-03-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  15. Environmental Regulatory Update Table July/August 1993

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1993-09-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  16. Environmental Regulatory Update Table, March/April 1993

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1993-05-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bimonthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  17. Environmental Regulatory Update Table, November--December 1992

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Lewis, E.B.; Salk, M.S.

    1993-01-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly wit information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  18. Environmental Regulatory Update Table, July--August 1992

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Lewis, E.B.; Salk, M.S.

    1992-09-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  19. Environmental Regulatory Update Table, September/October 1993

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1993-11-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operation and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  20. Environmental Regulatory Update Table, January--February 1994

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1994-03-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations ad contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  1. Environmental regulatory update table, September--October 1992

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Lewis, E.B.; Salk, M.S.

    1992-11-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  2. Environmental regulatory update table, July/August 1994

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Bock, R.E.; Salk, M.S.

    1994-09-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  3. Environmental Regulatory Update Table, March/April 1992

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.

    1992-05-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  4. Environmental regulatory update table, July/August 1994

    International Nuclear Information System (INIS)

    Houlberg, L.M.; Hawkins, G.T.; Bock, R.E.; Salk, M.S.

    1994-09-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action

  5. Development and current state of dosimetry in Cuba

    International Nuclear Information System (INIS)

    Prieto Miranda, E.F.; Cuesta Fuente, G.; Chavez Ardanza, A.

    1999-01-01

    In Cuba, the application of the radiation technologies has been growing in the last years, and at present there are several dosimetry systems with different ranges of absorbed dose. Diverse researches were carried out on high dose dosimetry with the following dosimetry systems: Fricke, ceric-cerous sulfate, ethanol-chlorobenzene, cupric sulfate and Perspex (Red 4034 AE and Clear HX). In this paper the development achieved during the last 15 years in the high dose dosimetry for radiation processing in Cuba is presented, as well as, the current state of different dosimetry systems employed for standardization and for process control. The paper also reports the results of dosimetry intercomparison studies that were performed with the Ezeiza Atomic Center of Argentine and the International Dose Assurance Service (IDAS) of IAEA. (author)

  6. Probabilistic accident consequence uncertainty analysis -- Uncertainty assessment for internal dosimetry. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Goossens, L.H.J.; Kraan, B.C.P.; Cooke, R.M. [Delft Univ. of Technology (Netherlands); Harrison, J.D. [National Radiological Protection Board (United Kingdom); Harper, F.T. [Sandia National Labs., Albuquerque, NM (United States); Hora, S.C. [Univ. of Hawaii, Hilo, HI (United States)

    1998-04-01

    The development of two new probabilistic accident consequence codes, MACCS and COSYMA, was completed in 1990. These codes estimate the consequence from the accidental releases of radiological material from hypothesized accidents at nuclear installations. In 1991, the US Nuclear Regulatory Commission and the Commission of the European Communities began cosponsoring a joint uncertainty analysis of the two codes. The ultimate objective of this joint effort was to systematically develop credible and traceable uncertainty distributions for the respective code input variables. A formal expert judgment elicitation and evaluation process was identified as the best technology available for developing a library of uncertainty distributions for these consequence parameters. This report focuses on the results of the study to develop distribution for variables related to the MACCS and COSYMA internal dosimetry models. This volume contains appendices that include (1) a summary of the MACCS and COSYMA consequence codes, (2) the elicitation questionnaires and case structures, (3) the rationales and results for the panel on internal dosimetry, (4) short biographies of the experts, and (5) the aggregated results of their responses.

  7. Oak Ridge National Laboratory Embrittlement Data Base (EDB) and Dosimetry Evaluation (DE) program

    International Nuclear Information System (INIS)

    Pace, J.V. III; Remec, I.; Wang, J.A.; White, J.E.

    1996-01-01

    The objective of this program is to develop, maintain, and upgrade computerized data bases, calculational procedures, and standards relating to reactor pressure vessel fluence spectra determinations and embrittlement assessments. As part of this program, the information from radiation embrittlement research on nuclear reactor pressure vessel steels and from power reactor surveillance reports is maintained in a data base published on a periodic basis. The Embrittlement Data Base (EDB) effort consists of verifying the quality of the EDB, providing user-friendly software to access and process the data, and exploring and assessing embrittlement prediction models. The Dosimetry Evaluation effort consists of maintaining and upgrading validated neutron and gamma radiation transport procedures, maintaining cross-section libraries with the latest evaluated nuclear data, and maintaining and updating validated dosimetry procedures and data bases. The information available from this program provides data for assisting the Office of Nuclear Reactor Regulation, with support from the Office of Nuclear Regulatory Research, to effectively monitor current procedures and data bases used by vendors, utilities, and service laboratories in the pressure vessel irradiation surveillance program

  8. Consistency of external dosimetry in epidemiologic studies of nuclear workers

    International Nuclear Information System (INIS)

    Fix, J.J.; Gilbert, E.S.

    1992-01-01

    Efforts are underway to pool data from epidemiologic studies of nuclear workers to obtain more precise estimates of radiation risk than would be possible from any single study. The International Agency for Research on Cancer (IARC) is coordinating combined analyses of data from studies in the United States, Canada, and the United Kingdom. In the U.S., the Department of Energy (DOE) has established the Comprehensive Epidemiologic Data Resource (CEDR) to provide investigators an opportunity to analyze data from several DOE laboratories. IARC investigators, in collaboration with those conducting the individual studies, have developed a dosimetry protocol for the international combined analyses. (author)

  9. Consistency of external dosimetry in epidemiologic studies of nuclear workers

    International Nuclear Information System (INIS)

    Fix, J.J.; Gilbert, E.S.

    1992-05-01

    Efforts are underway to pool data from epidemiologic studies of nuclear workers to obtain more precise estimates of radiation risk than would be possible from any single study. The International Agency for Research on Cancer (IARC) is coordinating combined analyses of data from studies in the United States, Canada, and the United Kingdom. In the US, the Department of Energy (DOE) has established the Comprehensive Epidemiologic Data Resource (CEDR) to provide investigators an opportunity to analyze data from several DOE laboratories. IARC investigators, in collaboration with those conducting the individual studies, have developed a dosimetry protocol for the international combined analyses

  10. 76 FR 41585 - Regulation and Independent Regulatory Agencies

    Science.gov (United States)

    2011-07-14

    ... permitted by law, such decisions should be made only after consideration of their costs and benefits (both... concerning public participation, integration and innovation, flexible approaches, and science. To the extent... public a plan, consistent with law and reflecting its resources and regulatory priorities and processes...

  11. Scientific committee of the IAEA/WHO Network of Secondary Standard Dosimetry Laboratories. Report of the ninth meeting of the SSDL scientific committee, IAEA, Vienna, 13-17 November 2000

    International Nuclear Information System (INIS)

    2001-01-01

    The report of the eighth meeting (held in Oct. 1998) of the Scientific Committee (SSC) of the IAEA/WHO network of Secondary Standard Dosimetry Laboratories (SSDL) was published in the SSDL Newsletter No. 40, January 1999. The ninth meeting was held in Vienna at Agency Headquarters from 13 to 17 November 2000. Opening remarks were made by Mr. S. Groth, Director, Division of Human Health (NAHU), Mr. H. Oestensen (WHO), Co-Secretary of the IAEA/WHO SSDL Network, and Mr. Ahmed Meghzifene, acting Section Head, Dosimetry and Medical Radiation Physics (DMRP). The Agency's DMRP sub-programme provides traceable radiation standards to the majority of developing countries over a wide range of energies and dose levels. External-beam radiation therapy and radiation processing (high dose) have a long history and robust links to international standards. Recently the DMRP has developed projects providing robust links for calibration of mammography X-ray beams, brachytherapy sources, and personnel monitoring programmes at the participating SSDLs. Efforts by the Agency and the WHO over the past 5 years have made significant improvements in the return rate and turn-around time in the postal TLD programme, effectively increasing the availability of Agency standards. Two other high-priority items promulgated by the DMRP are: (i) follow-up of quality audit measurements which fall outside the established action levels, and (ii) transfer of postal TLD programmes to national programmes and establishing and maintaining links between these programmes and the DMRP. The SSC still considers both of these as high priority items, commends the DMRP on their efforts, and encourages them to continue to develop activities in these areas. The SSC wishes to emphasize that radiation dosimetry is a necessary adjunct to many programmes that utilize ionizing radiation at various dose levels. The SSC commends the Agency for their continued support for the programmes sponsored through the Dosimetry and

  12. Miniature semiconductor detectors for in vivo dosimetry

    International Nuclear Information System (INIS)

    Rosenfeld, A. B.; Cutajar, D.; Lerch, M. L. F.; Takacs, G.; Cornelius, I. M.; Yudelev, M.; Zaider, M.

    2006-01-01

    Silicon mini-semiconductor detectors are found in wide applications for in vivo personal dosimetry and dosimetry and Micro-dosimetry of different radiation oncology modalities. These applications are based on integral and spectroscopy modes of metal oxide semiconductor field effect transistor and silicon p-n junction detectors. The advantages and limitations of each are discussed. (authors)

  13. Quality assurance program in the External dosimetry laboratory of the CPHR

    International Nuclear Information System (INIS)

    Molina P, D.; Pernas S, R.; Martinez H, E.; Cardenas H, J.

    2006-01-01

    From 1999 the Laboratory of External Dosimetry of the Radiation Protection and Hygiene Center comes applying in its service of personal dosimetry a Program of Quality Assurance. This program was designed according to the recommendations of national and international organizations as the National Assuring Office of the Republic of Cuba (ONARC), the International Standards Organization (ISO), the International Electro technique Commission (IEC) and the International Atomic Energy Agency (IAEA). In this work it is presented in a summarized way the operation of this Program of Quality Assurance which includes the administration and conservation of the results and the documentation of the service, the controls that are carried out to the equipment, the acceptance tests that are applied to the equipment and new dosemeters, the shipment and prosecution of the dosemeters, the evaluation, storage and conservation of the doses, the report of the results, the traceability and reproducibility of the measurements, the attention to the reclamations and the clients complaints and the internal and external audits to those that it undergoes periodically the laboratory. (Author)

  14. NASA's Agency-Wide Strategy for Environmental Regulatory Risk Analysis and Communication

    Science.gov (United States)

    Scroggins, Sharon; Duda, Kristen

    2008-01-01

    This viewgraph presentation gives an overview of NASA's risk analysis communication programs associated with changing environmental policies. The topics include: 1) NASA Program Transition; 2) Principal Center for Regulatory Risk Analysis and Communication (RRAC PC); and 3) Regulatory Tracking and Communication Process.

  15. Computer-assisted planning and dosimetry for radiation treatment of head and neck cancer in Cameroon

    International Nuclear Information System (INIS)

    Yomi, J.; Ngniah, A.; Kingue, S.; Muna, W.F.T.; Durosinmi-Etti, F.A.

    1995-01-01

    This evaluation was part of a multicenter, multinational study sponsored by the International Agency for Atomic Energy (Vienna) to investigate a simple, reliable computer-assisted planning and dosimetry system for radiation treatment of head and neck cancers in developing countries. Over a 13-month period (April 1992-April 1993), 120 patients with histologically-proven head or neck cancer were included in the evaluation. In each patient, planning and dosimetry were done both manually and using the computer-assisted system. The manual and computerized systems were compared on the basis of accuracy of determination of the outer contour, target volume, and critical organs; volume inequality resolution; structure heterogeneity correction; selection of the number, angle, and size of beams; treatment time calculation; availability of dosimetry predictions; and duration and cost of the procedure. Results demonstrated that the computer-assisted procedure was superior over the manual procedure, despite less than optimal software. The accuracy provided by the completely computerized procedure is indispensable for Level II radiation therapy, which is particularly useful in tumors of the sensitive, complex structures in the head and neck. (authors). 7 refs., 3 tabs

  16. Accreditation and training on internal dosimetry in a laboratory network in Brazil: an increasing demand.

    Science.gov (United States)

    Dantas, B M; Dantas, A L A; Acar, M E D; Cardoso, J C S; Julião, L M Q C; Lima, M F; Taddei, M H T; Arine, D R; Alonso, T; Ramos, M A P; Fajgelj, A

    2011-03-01

    In recent years, Brazilian Nuclear Programme has been reviewed and updated by government authorities in face of the demand for energy supply and its associated environmental constraints. The immediate impact of new national programmes and projects in nuclear field is the increase in the number of exposed personnel and the consequent need for reliable dosimetry services in the country. Several Technical Documents related to internal dosimetry have been released by the International Atomic Energy Agency and International Commission on Radiological Protection. However, standard bioassay procedures and methodologies for bioassay data interpretation are still under discussion and, in some cases, both in routine and emergency internal monitoring, procedures can vary from one laboratory to another and responses may differ markedly among Dosimetry Laboratories. Thus, it may be difficult to interpret and use bioassay data generated from different laboratories of a network. The main goal of this work is to implement a National Network of Laboratories aimed to provide reliable internal monitoring services in Brazil. The establishment of harmonised in vivo and in vitro radioanalytical techniques, dose assessment methods and the implementation of the ISO/IEC 17025 requirements will result in the recognition of technical competence of the network.

  17. Chemical dosimetry system for criticality accidents.

    Science.gov (United States)

    Miljanić, Saveta; Ilijas, Boris

    2004-01-01

    Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values.

  18. Relative efficacy of drugs: an emerging issue between regulatory agencies and third-party payers.

    Science.gov (United States)

    Eichler, Hans-Georg; Bloechl-Daum, Brigitte; Abadie, Eric; Barnett, David; König, Franz; Pearson, Steven

    2010-04-01

    Drug regulatory agencies have traditionally assessed the quality, safety and efficacy of drugs, and the current paradigm dictates that a new drug should be licensed when the benefits outweigh the risks. By contrast, third-party payers base their reimbursement decisions predominantly on the health benefits of the drug relative to existing treatment options (termed relative efficacy; RE). Over the past decade, the role of payers has become more prominent, and time-to-market no longer means time-to-licensing but time-to-reimbursement. Companies now have to satisfy the sometimes divergent needs of both regulators and payers, and to address RE during the pre-marketing stages. This article describes the current political background to the RE debate and presents the scientific and methodological challenges as they relate to RE assessment. In addition, we explain the impact of RE on drug development, and speculate on future developments and actions that are likely to be required from key players.

  19. 78 FR 1624 - Fall 2012 Regulatory Agenda

    Science.gov (United States)

    2013-01-08

    ...), studies or analyses of the possible need for regulatory action, requests for public comment on the need... (NESHAP): Reinforced Plastic Composites Production To comment or learn more about these retrospective.... Agency Contact: Hans Scheifele, Environmental Protection Agency, Office of Chemical Safety and Pollution...

  20. Measurement uncertainty. A practical guide for Secondary Standards Dosimetry Laboratories

    International Nuclear Information System (INIS)

    2008-05-01

    The need for international traceability for radiation dose measurements has been understood since the early nineteen-sixties. The benefits of high dosimetric accuracy were recognized, particularly in radiotherapy, where the outcome of treatments is dependent on the radiation dose delivered to patients. When considering radiation protection dosimetry, the uncertainty may be greater than for therapy, but proper traceability of the measurements is no less important. To ensure harmonization and consistency in radiation measurements, the International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) created a Network of Secondary Standards Dosimetry Laboratories (SSDLs) in 1976. An SSDL is a laboratory that has been designated by the competent national authorities to undertake the duty of providing the necessary link in the traceability chain of radiation dosimetry to the international measurement system (SI, for Systeme International) for radiation metrology users. The role of the SSDLs is crucial in providing traceable calibrations; they disseminate calibrations at specific radiation qualities appropriate for the use of radiation measuring instruments. Historically, although the first SSDLs were established mainly to provide radiotherapy level calibrations, the scope of their work has expanded over the years. Today, many SSDLs provide traceability for radiation protection measurements and diagnostic radiology in addition to radiotherapy. Some SSDLs, with the appropriate facilities and expertise, also conduct quality audits of the clinical use of the calibrated dosimeters - for example, by providing postal dosimeters for dose comparisons for medical institutions or on-site dosimetry audits with an ion chamber and other appropriate equipment. The requirements for traceable and reliable calibrations are becoming more important. For example, for international trade where radiation products are manufactured within strict quality control systems, it is

  1. Toward a functional definition of a "rare disease" for regulatory authorities and funding agencies.

    Science.gov (United States)

    Clarke, Joe T R; Coyle, Doug; Evans, Gerald; Martin, Janet; Winquist, Eric

    2014-12-01

    The designation of a disease as "rare" is associated with some substantial benefits for companies involved in new drug development, including expedited review by regulatory authorities and relaxed criteria for reimbursement. How "rare disease" is defined therefore has major financial implications, both for pharmaceutical companies and for insurers or public drug reimbursement programs. All existing definitions are based, somewhat arbitrarily, on disease incidence or prevalence. What is proposed here is a functional definition of rare based on an assessment of the feasibility of measuring the efficacy of a new treatment in conventional randomized controlled trials, to inform regulatory authorities and funding agencies charged with assessing new therapies being considered for public funding. It involves a five-step process, involving significant negotiations between patient advocacy groups, pharmaceutical companies, physicians, and public drug reimbursement programs, designed to establish the feasibility of carrying out a randomized controlled trial with sufficient statistical power to show a clinically significant treatment effect. The steps are as follows: 1) identification of a specific disease, including appropriate genetic definition; 2) identification of clinically relevant outcomes to evaluate efficacy; 3) establishment of the inherent variability of measurements of clinically relevant outcomes; 4) calculation of the sample size required to assess the efficacy of a new treatment with acceptable statistical power; and 5) estimation of the difficulty of recruiting an adequate sample size given the estimated prevalence or incidence of the disorder in the population and the inclusion criteria to be used. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  2. Dosimetry as an integral part of radiation processing

    International Nuclear Information System (INIS)

    Zagorski, Z.P.

    1999-01-01

    Different connections between high-dose dosimetry and radiation processing are discussed. Radiation processing cannot be performed without proper dosimetry. Accurate high dose and high dose rate dosimetry exhibits several aspects: first of all it is the preservation of the quality of the product, then fulfillment of legal aspects and last but not the least the safety of processing. Further, seldom discussed topics are as follow: dosimetric problems occurring with double-side EB irradiations, discussed in connection with the deposition of electric charge during electron beam irradiation. Although dosimetry for basic research and for medical purposes are treated here only shortly, some conclusions reached from these fields are considered in dosimetry for radiation processing. High-dose dosimetry of radiation has become a separate field, with many papers published every year, but applied dosimetric projects are usually initiated by a necessity of particular application. (author)

  3. 77 FR 28467 - Identifying and Reducing Regulatory Burdens

    Science.gov (United States)

    2012-05-14

    ... online wherever practicable. Sec. 3. Setting Priorities. In implementing and improving their... regulatory priorities, to promote public participation in retrospective review, to modernize our regulatory..., agencies shall give priority, consistent with law, to those initiatives that will produce significant...

  4. The work programme of EURADOS on internal and external dosimetry.

    Science.gov (United States)

    Rühm, W; Bottollier-Depois, J F; Gilvin, P; Harrison, R; Knežević, Ž; Lopez, M A; Tanner, R; Vargas, A; Woda, C

    2018-01-01

    Since the early 1980s, the European Radiation Dosimetry Group (EURADOS) has been maintaining a network of institutions interested in the dosimetry of ionising radiation. As of 2017, this network includes more than 70 institutions (research centres, dosimetry services, university institutes, etc.), and the EURADOS database lists more than 500 scientists who contribute to the EURADOS mission, which is to promote research and technical development in dosimetry and its implementation into practice, and to contribute to harmonisation of dosimetry in Europe and its conformance with international practices. The EURADOS working programme is organised into eight working groups dealing with environmental, computational, internal, and retrospective dosimetry; dosimetry in medical imaging; dosimetry in radiotherapy; dosimetry in high-energy radiation fields; and harmonisation of individual monitoring. Results are published as freely available EURADOS reports and in the peer-reviewed scientific literature. Moreover, EURADOS organises winter schools and training courses on various aspects relevant for radiation dosimetry, and formulates the strategic research needs in dosimetry important for Europe. This paper gives an overview on the most important EURADOS activities. More details can be found at www.eurados.org .

  5. Dosimetry and operation of irradiation facilities

    International Nuclear Information System (INIS)

    Vidal, P.E.

    1985-01-01

    The industrial use of ionizing radiation has required, from the very first, the measurement of delivered and absorbed doses; hence the necessity of providing dosimetric systems. Laboratories, scientists, industries and potential equipment manufacturers have all collaborated in this new field of activity. Dosimetric intercomparisons have been made by each industry at their own facilities and in collaboration with specialists, national organizations and the IAEA. Dosimetry has become a way of ensuring that treatment by irradiation has been carried out in accordance with the rules. It has become in effect assurance of quality. Routine dosimetry should determine a maximum and minimum dose. Numerous factors play a part in dosimetry. Industry is currently in possession of routine dosimetric systems that are sufficiently accurate, fairly easy to handle and reasonable in cost, thereby satisfying all the requirements of industry and the need for control. Dosimetry is important in the process of marketing irradiated products. The operator of an industrial irradiation facility bases his dosimetry on comparison with reference systems. Research aimed at simplifying the practice of routine dosimetry should be continued. New physical and chemical techniques will be incorporated into systems already in use. The introduction of microcomputers into the operation of radiation facilities has increased the value of dosimetry and made the conditions of treatment more widespread. Stress should be placed on research in several areas apart from reference systems, for example: dosimetric systems at temperatures from +8 deg. C to -45 deg. C, over the dose range 100 krad to a little more than 1 Mrad, liquids and fluidized solids carried at high speed through ducts, thin-film liquids circulating at a high flow rate, and various other problems. (author)

  6. Foundations of ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Denisenko, O.N.; Pereslegin, I.A.

    1985-01-01

    Foundations of dosimetry in application to radiotherapy are presented. General characteristics of ionizing radiations and main characteristics of ionizing radiation sources, mostly used in radiotherapy, are given. Values and units for measuring ionizing radiation (activity of a radioactive substance, absorbed dose, exposure dose, integral dose and dose equivalent are considered. Different methods and instruments for ionizing radiation dosimetry are discussed. The attention is paid to the foundations of clinical dosimetry (representation of anatomo-topographic information, choice of radiation conditions, realization of radiation methods, corrections for a configuration and inhomogeneity of a patient's body, account of biological factors of radiation effects, instruments of dose field formation, control of irradiation procedure chosen)

  7. 78 FR 1634 - Regulatory Agenda

    Science.gov (United States)

    2013-01-08

    ... amendments include updates to organizational information, use of the term ``disability'' in lieu of the term.../00/13 Regulatory Flexibility Analysis Required: No. Agency Contact: Robert W. Cosgrove, External...

  8. 78 FR 44329 - Regulatory Agenda

    Science.gov (United States)

    2013-07-23

    ... amendments include updates to organizational information, use of the term ``disability'' in lieu of the term.../00/13 Regulatory Flexibility Analysis Required: No. Agency Contact: Robert W. Cosgrove, External...

  9. 76 FR 18457 - Regulatory Review Schedule; Tribal Consultation

    Science.gov (United States)

    2011-04-04

    ... that the NIGC provide tribal gaming commissions access to licensing information via an online database... DEPARTMENT OF THE INTERIOR National Indian Gaming Commission 25 CFR Chapter III Regulatory Review Schedule; Tribal Consultation AGENCY: National Indian Gaming Commission. ACTION: Notice of Regulatory...

  10. Regulatory controls for NORM contamination: Emerging issues and strategies

    International Nuclear Information System (INIS)

    Wennerberg, Linda

    1992-01-01

    Naturally occurring and accelerator-produced radioactive material (NORM) faces the increasing likelihood of federal or state regulatory control. Public concern and limited preliminary survey data fuel the debate over the necessity, approach, and jurisdiction of a NORM regulatory strategy. This debate requires the resolution of technical controversies and potentially competing state and federal agency interests. An additional facet of the debate is the impact of regulation upon traditionally non-nuclear industries, such as oil and gas production. Regulatory response has been initiated in several states, such as Louisiana's controls on equipment used in oil and gas production, to control specific industrial activities which generate NORM. A more comprehensive, generic federal strategy to control NORM contamination is also under review by the Environmental Protection Agency. This paper will detail the emerging technical issues, federal and state regulatory strategies under consideration, and evaluate the efficacy of selected regulatory approaches. (author)

  11. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  12. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2006-01-01

    The object of this paper is to give a new user some practical information on the use of radiochromic films for medical applications. While various aspects of radiochromic film dosimetry for medical applications have been covered in some detail in several other excellent review articles which have appeared in the last few years [Niroomand-Rad, A., Blackwell, C.R., Coursey, B.M., Gall, K.P., McLaughlin, W.L., Meigooni, A.S., Nath, R., Rodgers, J.E., Soares, C.G., 1998. Radiochromic dosimetry: recommendations of the AAPM Radiation Therapy Committee Task Group 55. Med. Phys. 25, 2093-2115; Dempsey, J.F., Low, D.A., Mutic, S., Markman, J., Kirov, A.S., Nussbaum, G.H., Williamson, J.F., 2000. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions. Med. Phys. 27, 2462-2475; Butson, M.J., Yu, P.K.N., Cheung, T., Metcalfe, P., 2003. Radiochromic film for medical radiation dosimetry. Mater. Sci. Eng. R41, 61-120], it is the intent of the present author to present material from a more user-oriented and practical standpoint. That is, how the films work will be stressed much less than how to make the films work well. The strength of radiochromic films is most evident in applications where there is a very high dose gradient and relatively high absorbed dose rates. These conditions are associated with brachytherapy applications, measurement of small fields, and at the edges (penumbra regions) of larger fields

  13. 7 CFR 371.5 - Marketing and Regulatory Programs Business Services.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Marketing and Regulatory Programs Business Services... AUTHORITY § 371.5 Marketing and Regulatory Programs Business Services. (a) General statement. Marketing and Regulatory Programs Business Services (MRPBS) plans and provides for the agency's human, financial, and...

  14. 77 FR 15142 - Updated Nuclear Regulatory Commission Fiscal Years 2008-2013 Strategic Plan

    Science.gov (United States)

    2012-03-14

    ... 2008-2013 Strategic Plan AGENCY: Nuclear Regulatory Commission. ACTION: Strategic plan. SUMMARY: The U...-1614, Volume 5, ``U.S. Nuclear Regulatory Commission, Fiscal Years [FY] 2008-2013 Strategic Plan,'' dated February 2012. The updated FY 2008-2013 strategic plan describes the agency's mission and...

  15. Performing personnel dosimetry investigations and records quality assurance

    International Nuclear Information System (INIS)

    Perle, S.C.

    2002-01-01

    Radiation Safety Officers (RSOs) sometimes face situations in which personnel dosimetry estimates are required after dosimeters issued to radiation workers (film or TLD badges, extremity dosimeters, etc.) are lost or damaged before processing. This article was prepared to help those involved with personnel dosimetry investigations became aquatinted with this process. A factor that contributes to the anxiety of those unfamiliar with dosimetry investigations is the lack of published guidance available in this subject. More printed resources are needed to help radiation safety professionals familiarize themselves and understand personnel dosimetry investigations. Topics discussed in this presentation include the justification of performing dosimetry investigations, recommendations on how to perform them and the advantages of performing such investigations

  16. Dosimetry and Shielding of X and Gamma Radiation

    International Nuclear Information System (INIS)

    Oncescu, M.; Panaitescu, I.

    1992-01-01

    This book covers the following problems: 1. X and Gamma radiations, 2. Interaction of X-ray and gamma radiations with matter, 3. Interaction of electrons with matter, 4. Principles and basic concepts of dosimetry, 5. Ionization dosimetry, 6. Calorimetric chemical and photographic dosimetry, 7. Solid state dosimetry, 8. Computation of dosimetric quantities, 9. Dosimetry in radiation protection, 10. Shielding of X and gamma radiations. The authors, well-known Romanian experts in Radiation Physics and Engineering, gave an up-dated, complete and readable account of this subject matter. The analyses of physical principles and concepts, of materials and instruments and of computational methods and applications are all well balanced to meat the needs of a broad readership

  17. Radiotherapy Based On α Emitting Radionuclides: Geant4 For Dosimetry And Micro-/Nano-Dosimetry

    International Nuclear Information System (INIS)

    Guatelli, Susanna

    2013-01-01

    Possible physics approaches to evaluate the efficacy of TAT are dosimetry, microdosimetry and nanodosimetry. Dosimetry is adequate when mean absorbed dose to a macroscopic target volume is important to understand the biological effect of radiation. General purpose Monte Carlo (MC) codes, based on condensed history approach, are a very useful, cost effective tool to solve dosimetric problems. The condensed history approach is based on the use of multiple scattering theories to calculate the energy losses and angular changes in the direction of the particle. The short α particle range and high LET make the microdosimetric approach more suitable than dosimetry to study TAT from first physics principles, as this approach takes into account the stochastic nature of energy deposition at cellular level

  18. Updating the INDAC computer application of internal dosimetry

    International Nuclear Information System (INIS)

    Bravo Perez-Tinao, B.; Marchena Gonzalez, P.; Sollet Sanudo, E.; Serrano Calvo, E.

    2013-01-01

    The initial objective of this project is to expand the application INDAC currently used in internal dosimetry services of the Spanish nuclear power plants and Tecnatom for estimating the effective doses of internal dosimetry of workers in direct action. or in-vivo dosimetry. (Author)

  19. Dosimetry methods

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, A.; Kovacs, A.

    2003-01-01

    Chemical and physical radiation dosimetry methods, used for the measurement of absorbed dose mainly during the practical use of ionizing radiation, are discussed with respect to their characteristics and fields of application....

  20. Intergovernmental organisation activities: European Atomic Energy Community, International Atomic Energy Agency, OECD Nuclear Energy Agency

    International Nuclear Information System (INIS)

    Anon.

    2012-01-01

    European Atomic Energy Community: Proposed legislative instruments, Adopted legislative instruments, Non-legislative instruments, Other activities (meetings). International Atomic Energy Agency: IAEA Action Plan on Nuclear Safety. OECD Nuclear Energy Agency: The Russian Federation to join the OECD Nuclear Energy Agency; Participation by the regulatory authorities of India and the United Arab Emirates in the Multinational Design Evaluation Programme (MDEP); NEA International Workshop on Crisis Communication, 9-10 May 2012; International School of Nuclear Law: 2013; Next NEA International Nuclear Law Essentials Course

  1. Radiation dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Stabin, M.G.; Tagesson, M.; Ljungberg, M.; Strand, S.E.; Thomas, S.R.

    1999-01-01

    Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. A knowledge of the radiation dose received by different organs in the body is essential to an evaluation of the risks and benefits of any procedure. In this paper, current methods for internal dosimetry are reviewed, as they are applied in nuclear medicine. Particularly, the Medical Internal Radiation Dose (MIRD) system for dosimetry is explained, and many of its published resources discussed. Available models representing individuals of different age and gender, including those representing the pregnant woman are described; current trends in establishing models for individual patients are also evaluated. The proper design of kinetic studies for establishing radiation doses for radiopharmaceuticals is discussed. An overview of how to use information obtained in a dosimetry study, including that of the effective dose equivalent (ICRP 30) and effective dose (ICRP 60), is given. Current trends and issues in internal dosimetry, including the calculation of patient-specific doses and in the use of small scale and microdosimetry techniques, are also reviewed

  2. An IAEA Survey of Dosimetry Audit Networks for Radiotherapy

    International Nuclear Information System (INIS)

    Grochowska, Paulina; Izewska, Joanna

    2013-01-01

    A Survey: In 2010, the IAEA undertook a task to investigate and review the coverage and operations of national and international dosimetry audit programmes for radiotherapy. The aim was to organize the global database describing the activities of dosimetry audit networks in radiotherapy. A dosimetry audit questionnaire has been designed at an IAEA consultants' meeting held in 2010 for organizations conducting various levels of dosimetry audits for radiotherapy. Using this questionnaire, a survey was conducted for the first time in 2010 and repeated in 2011. Request for information on different aspects of the dosimetry audit was included, such as the audit framework and resources, its coverage and scope, the dosimetry system used and the modes of audit operation, i.e. remotely and through on-site visits. The IAEA questionnaire was sent to over 80 organizations, members of the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories (SSDLs) and other organizations known for having operated dosimetry audits for radiotherapy in their countries or internationally. Survey results and discussion: In response to the IAEA survey, 53 organizations in 45 countries confirmed that they operate dosimetry audit services for radiotherapy. Mostly, audits are conducted nationally, however there are five organizations offering audits abroad, with two of them operating in various parts of the world and three of them at the regional level, auditing radiotherapy centres in neighbouring countries. The distribution of dosimetry audit services in the world is given. (author)

  3. Personnel neutron dosimetry at Department of Energy facilities

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.; Selby, J.M.; Vallario, E.J.

    1980-08-01

    This study assesses the state of personnel neutron dosimetry at DOE facilities. A survey of the personnel dosimetry systems in use at major DOE facilities was conducted, a literature search was made to determine recent advances in neutron dosimetry, and several dosimetry experts were interviewed. It was concluded that personnel neutron dosimeters do not meet current needs and that serious problems exist now and will increase in the future if neutron quality factors are increased and/or dose limits are lowered

  4. Internal dosimetry hazard and risk assessments: methods and applications

    International Nuclear Information System (INIS)

    Roberts, G.A.

    2006-01-01

    Routine internal dose exposures are typically (in the UK nuclear industry) less than external dose exposures: however, the costs of internal dosimetry monitoring programmes can be significantly greater than those for external dosimetry. For this reason decisions on when to apply routine monitoring programmes, and the nature of these programmes, can be more critical than for external dosimetry programmes. This paper describes various methods for performing hazard and risk assessments which are being developed by RWE NUKEM Limited Approved Dosimetry Services to provide an indication when routine internal dosimetry monitoring should be considered. (author)

  5. Radiation protection dosimetry in medicine - Report of the working group n.9 of the European radiation dosimetry group (EURADOS) - coordinated network for radiation dosimetry (CONRAD - contract EC N) fp6-12684; Dosimetrie pour la radioprotection en milieu medical - rapport du groupe de travail n. 9 du European radiation dosimetry group (EURADOS) - coordinated netword for radiation dosimetry (CONRAD - contrat CE fp6-12684)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    This report present the results achieved within the frame of the work the WP 7 (Radiation Protection Dosimetry of Medical Staff) of the coordination action CONRAD (Coordinated Network for Radiation Dosimetry) funded through the 6. EU Framework Program. This action was coordinated by EURADOS (European Radiation Dosimetry Group). EURADOS is an organization founded in 1981 to advance the scientific understanding and the technical development of the dosimetry of ionising radiation in the fields of radiation protection, radiobiology, radiation therapy and medical diagnosis by promoting collaboration between European laboratories. WP7 coordinates and promotes European research for the assessment of occupational exposures to staff in therapeutic and diagnostic radiology workplaces. Research is coordinated through sub-groups covering three specific areas: 1. Extremity dosimetry in nuclear medicine and interventional radiology: this sub-group coordinates investigations in the specific fields of the hospitals and studies of doses to different parts of the hands, arms, legs and feet; 2. Practice of double dosimetry: this sub-group reviews and evaluates the different methods and algorithms for the use of dosemeters placed above and below lead aprons in large exposure during interventional radiology procedures, especially to determine effective doses to cardiologists during cardiac catheterization; and 3. Use of electronic personal dosemeters in interventional radiology: this sub-group coordinates investigations in laboratories and hospitals, and intercomparisons with passive dosemeters with the aim to enable the formulation of standards. (authors)

  6. Accuracy Requirements in Medical Radiation Dosimetry

    International Nuclear Information System (INIS)

    Andreo, P.

    2011-01-01

    The need for adopting unambiguous terminology on 'accuracy in medical radiation dosimetry' which is consistent with international recommendations for metrology is emphasized. Uncertainties attainable, or the need for improving their estimates, are analysed for the fields of radiotherapy, diagnostic radiology and nuclear medicine dosimetry. This review centres on uncertainties related to the first step of the dosimetry chain in the three fields, which in all cases involves the use of a detector calibrated by a standards laboratory to determine absorbed dose, air kerma or activity under reference conditions in a clinical environment. (author)

  7. Characterization of commercial MOSFETS electron dosimetry

    International Nuclear Information System (INIS)

    Carvajal, M. A.; Simancas, F.; Guirado, D.; Banqueri, J.; Vilches, M.; Lallena, A. M.; Palma, A. J.

    2011-01-01

    In recent years there have been commercial dosimetry devices based on transistors Metal-Oxide-Semiconductor (MOSFET) having a number of advantages over traditional systems for dosimetry in medical applications. These include the portability of the sensor element and a reading process quick and relatively simple dose, linearity, and so on. The use of electron beams is important in modern radiotherapy include its use in intra-operative radiotherapy (RIO). This paper presents an initial characterization of different business models MOSFET, not specific for radiation detection, to demonstrate their potential as sensors for electron beam dosimetry. (Author)

  8. Radiographic film orientation in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Suchowerska, N.; Davison, A.; Drew, J.; Metcalfe, P.

    1996-01-01

    Since the discovery of x-rays, film has been used as a detection medium for radiation. More recently radiographic film has become established as a practical tool for the measurement of dose distribution in radiotherapy. The accuracy and reproducibility of film dosimetry depends on photon energy, processing conditions and film plane orientation. The relationship between photon energy, processing conditions and film dosimetry accuracy has been studied. The role of film plane orientation is still controversial. The current work aims to clarify the effects film plane orientation has on film dosimetry. Poster 205. (author)

  9. Mapping knowledge investments in the aftermath of Hurricane Katrina: a new approach for assessing regulatory agency responses to environmental disaster

    International Nuclear Information System (INIS)

    Frickel, Scott; Campanella, Richard; Vincent, M. Bess

    2009-01-01

    In the aftermath of large-scale disasters, the public's dependency on federal and state agencies for information about public safety and environmental risk is acute. While formal rules and procedures are in place to guide policy decisions in environmental risk assessment of spatially concentrated hazards such as regulated waste sites or vacant city lots, standard procedures for risk assessment seem potentially less well-suited for urban-scale disaster zones where environmental hazards may be widely dispersed and widely varying. In this paper we offer a new approach for the social assessment of regulatory science in response to large-scale disaster, illustrating our methodology through a socio-spatial analysis of the U.S. Environmental Protection Agency's (EPA) hazard assessment in New Orleans, Louisiana, following Hurricane Katrina in 2005. We find that the agency's commitment of epistemic resources or 'knowledge investments' varied considerably across the flood-impacted portion of the city, concentrating in poorer and disproportionately African American neighborhoods previously known to be heavily contaminated. We address some of the study's social and policy implications, noting the multidimensionality and interactive nature of knowledge investments and the prospects for deepening and extending this approach through comparative research

  10. Environmental Regulatory Update Table, January/February 1992

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.

    1992-03-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bi-monthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action. This table is for January/February 1992.

  11. 76 FR 61402 - Draft Nuclear Regulatory Commission Fiscal Year 2012-2016 Strategic Plan

    Science.gov (United States)

    2011-10-04

    ...-2016 Strategic Plan AGENCY: Nuclear Regulatory Commission. ACTION: Draft NUREG; request for comment... comment on draft NUREG-1614, Volume 5. ``U.S. Nuclear Regulatory Commission, FY 2012-2016 Strategic Plan,'' dated September 2011. The NRC's draft FY 2012-2016 strategic plan describes the agency's mission and...

  12. Solid-state track recorder neutron dosimetry in light water reactor pressure vessel surveillance mockups

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Roberts, J.H.; Gold, R.; Preston, C.C.

    1984-09-01

    Solid-State Track Recorder (SSTR) measurements of neutron-induced fission rates have been made in several pressure vessel mockup facilities as part of the US Nuclear Regulatory Commission's (NRC) Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Program (LWR-PV-SDIP). The results of extensive physics-dosimetry measurements made at the Pool Critical Assembly (PCA) at Oak Ridge National Laboratory (ORNL) in Oak Ridge, TN are summarized. Included are 235 U, 238 U, 237 Np and 232 Th fission rates in the PCA 12/13, 8/7, and 4/12 SSC configurations. Additional low power measurements have been made in an engineering mockup at the VENUS critical assembly at CEN-SCK, Mol, Belgium. 237 Np and 238 U fission rates were made at selected locations in the VENUS mockup, which models the in-core and near-core regions of a pressurized water reactor (PWR). Absolute core power measurements were made at VENUS by exposing solid-state track recorders (SSTRs) to polished fuel pellets within in-core fuel pins. 8 references, 4 figures, 10 tables

  13. The personal dosimetry in Mexico

    International Nuclear Information System (INIS)

    Salazar, M.A.

    2006-01-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  14. Post-graduate course on radiation protection and nuclear safety. Vol. 1,2

    International Nuclear Information System (INIS)

    1998-01-01

    The course handbook on radiation protection and nuclear safety containing two parts some was prepared mainly by scientists of the Nuclear Regulatory Authority (ARN) of the Argentine Republic, under the auspices of the International Atomic Energy Agency. The contents o this handbook have the principals aspects: radiation detection, radio dosimetry, biological effects of the ionizing radiation, occupational exposure, environmental effects, contamination and decontamination, radioactive waste management, transport of radioactive materials, medical and industrial applications and the Argentine regulatory system

  15. Post-graduate course on radiation protection and nuclear safety. Vol. 1,2; Curso de post-grado en proteccion radiologica y seguridad nuclear. Tomo 1,2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-01

    The course handbook on radiation protection and nuclear safety containing two parts some was prepared mainly by scientists of the Nuclear Regulatory Authority (ARN) of the Argentine Republic, under the auspices of the International Atomic Energy Agency. The contents o this handbook have the principals aspects: radiation detection, radio dosimetry, biological effects of the ionizing radiation, occupational exposure, environmental effects, contamination and decontamination, radioactive waste management, transport of radioactive materials, medical and industrial applications and the Argentine regulatory system.

  16. US regulatory system for genetically modified [genetically modified organism (GMO), rDNA or transgenic] crop cultivars.

    Science.gov (United States)

    McHughen, Alan; Smyth, Stuart

    2008-01-01

    This paper reviews the history of the federal regulatory oversight of plant agricultural biotechnology in the USA, focusing on the scientific and political forces moulding the continually evolving regulatory structure in place today. Unlike most other jurisdictions, the USA decided to adapt pre-existing legislation to encompass products of biotechnology. In so doing, it established an overarching committee (Office of Science and Technology Policy) to study and distribute various regulatory responsibilities amongst relevant agencies: the Food and Drug Administration, Environmental Protection Agency and US Department of Agriculture. This paper reviews the history and procedures of each agency in the execution of its regulatory duties and investigates the advantages and disadvantages of the US regulatory strategy.

  17. Report on external occupational dosimetry in Canada

    International Nuclear Information System (INIS)

    1995-12-01

    In light of the new recommendations of the ICRP in Report 60 on dose quantities and dose limits, this working group was set up to examine the implications for external dosimetry in Canada. The operational quantities proposed by the ICRU are discussed in detail with regard to their applicability in Canada. The current occupational dosimetry services available in Canada are described as well as the several performance intercomparisons that have been carried out within the country as well as internationally. Recommendations are given with respect to standards for dosimetry, including accuracy and precision. More practical advice is given on the choice of dosimeter to use for external dosimetry, frequency of monitoring, and who should be monitored. Specific advice is given on the monitoring of pregnant workers and problem of non-uniform irradiation. Accident and emergency dosimetry are dealt with briefly. Suggestions are given regarding record keeping both for employers and for the national dose registry. 48 refs., 6 tabs., 1 fig

  18. ESR/tooth enamel dosimetry application to Chernobyl case: individual retrospective dosimetry of the liquidators and wild animals

    International Nuclear Information System (INIS)

    Bugai, A.; Baryakchtar, V.G.; Baran, N.

    1996-01-01

    ESR/tooth enamel dosimetry technique was used for individual retrospective dosimetry of the servicemen who had worked in 1986-1987 at the liquidation of consequences of the Chernobyl accident. For 18 investigated cases, the values varied from 0,10 (sensitivity limit) to 1,75 Gy. The same technique was used for individual dosimetry of wild animals boars, red deers, elks) hunted at contaminated 30-km area around the Chernobyl Power Plant. Measured values varied from 0,20 to 5,0 Gy/year and were compared with calculated for external and internal irradiation

  19. Dosimetry methods for fuels, cladding and structural materials

    International Nuclear Information System (INIS)

    Roettger, H.

    1980-01-01

    This volume of the proceedings of the symposium on reactor dosimetry covers the following topics: the metallurgy and dosimetry interface, radiation damage correlations of structural materials and damage analyses techniques, dosimetry for fusion materials, light water reactor pressure vessel surveillance in practice and irradiation experiments, fast reactor and reseach reactor characterization

  20. Glucinium dosimetry in beryl

    International Nuclear Information System (INIS)

    Kremer, M.

    1949-05-01

    The application of the method developed by Kolthoff and Sandell (1928) for the dosimetry of glucinium (beryllium) in beryl gives non-reproducible results with up to 20% discrepancies. This method recommends to separate beryllium and aluminium using 8 hydroxyquinoline and then to directly precipitate glucinium in the filtrate using ammonia. One possible reason of the problems generated by this method should be the formation of a volatile complex between beryllium and the oxine. This work shows that when the oxine is eliminated before the precipitation with ammonia the dosimetry of beryllium becomes accurate. The destruction of the oxine requires the dry evaporation of the filtrate, which is a long process. Thus the search for a reagent allowing the quantitative precipitation of beryllium in its solutions and in presence of oxine has been made. It has been verified also that the quantitative precipitation of the double beryllium and ammonium phosphate is not disturbed by the oxine in acetic buffer. This method, which gives good results, has also the advantage to separate beryllium from the alkaline-earth compounds still present in the filtrate. The report details the operation mode of the method: beryllium dosimetry using ammonium phosphate, aluminium-beryllium separation, application to beryl dosimetry (ore processing, insolubilization of silica, precipitation with ammonia, precipitation with oxine, precipitation of PO 4 NH 4 Gl, preciseness). (J.S.)

  1. Proceedings of the 5. symposium on neutron dosimetry. Beam dosimetry

    International Nuclear Information System (INIS)

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantitites, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  2. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    This paper summarizes the applications of ASTM standard methods, guides and practices to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and development of advanced dosimetry sets for commercial reactors is also summarized. (Auth.)

  3. Cross sections required for FMIT dosimetry

    International Nuclear Information System (INIS)

    Gold, R.; McElroy, W.N.; Lippincott, E.P.; Mann, F.M.; Oberg, D.L.; Roberts, J.H.; Ruddy, F.H.

    1980-01-01

    The Fusion Materials Irradiation Test (FMIT) facility, currently under construction, is designed to produce a high flux of high energy neutrons for irradiation effects experiments on fusion reactor materials. Characterization of the flux-fluence-spectrum in this rapidly varying neutron field requires adaptation and extension of currently available dosimetry techniques. This characterization will be carried out by a combination of active, passive, and calculational dosimetry. The goal is to provide the experimenter with accurate neutron flux-fluence-spectra at all positions in the test cell. Plans have been completed for a number of experimental dosimetry stations and provision for these facilities has been incorporated into the FMIT design. Overall needs of the FMIT irradiation damage program delineate goal accuracies for dosimetry that, in turn, create new requirements for high energy neutron cross section data. Recommendations based on these needs have been derived for required cross section data and accuracies

  4. Federal Energy Regulatory Commission (FERC) Regions

    Data.gov (United States)

    Department of Homeland Security — Federal Energy Regulatory Commission (FERC) Regions. FERC is an independent agency that regulates the interstate transmission of electricity, natural gas, and oil....

  5. Special workshop on lung dosimetry

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1983-01-01

    A Special Workshop on Lung Dosimetry was convened in Salt Lake City, Utah, on April 21-22, 1982, to stimulate the use of improved radiation dosimetry and to formulate a stronger basis for dose-response relationships for inhaled radionuclides. The two-day workshop was held in conjunction with the 30th Annual Meeting of the Radiation Research Society. Publication is planned

  6. Dosimetry of internal emitters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  7. Nuclear medicine radiation dosimetry

    CERN Document Server

    McParland, Brian J

    2010-01-01

    Complexities of the requirements for accurate radiation dosimetry evaluation in both diagnostic and therapeutic nuclear medicine (including PET) have grown over the past decade. This is due primarily to four factors: growing consideration of accurate patient-specific treatment planning for radionuclide therapy as a means of improving the therapeutic benefit, development of more realistic anthropomorphic phantoms and their use in estimating radiation transport and dosimetry in patients, design and use of advanced Monte Carlo algorithms in calculating the above-mentioned radiation transport and

  8. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: In June: Every morning from 8:30 to 12:00 In July: Mondays, Wednesdays and Fridays from 8:30 to 11:30 Closed all day on Tuesdays and Thursdays From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  9. Monte Carlo technique applications in field of radiation dosimetry at ENEA radiation protection institute: A Review

    International Nuclear Information System (INIS)

    Gualdrini, G.F.; Casalini, L.; Morelli, B.

    1994-12-01

    The present report summarizes the activities concerned with numerical dosimetry as carried out at the Radiation Protection Institute of ENEA (Italian Agency for New Technologies, Energy and the Environment) on photon dosimetric quantities. The first part is concerned with MCNP Monte Carlo calculation of field parameters and operational quantities for the ICRU sphere with reference photon beams for the design of personal dosemeters. The second part is related with studies on the ADAM anthropomorphic phantom using the SABRINA and MCNP codes. The results of other Monte Carlo studies carried out on electron conversion factors for various tissue equivalent slab phantoms are about to be published in other ENEA reports. The report has been produced in the framework of the EURADOS WG4 (numerical dosimetry) activities within a collaboration between the ENEA Environmental Department and ENEA Energy Department

  10. RCA/IAEA third external dosimetry intercomparison in East Asia

    International Nuclear Information System (INIS)

    Momose, T.; Yamamoto, H.; Cruz Suarez, R.

    2005-01-01

    Full text: Several intercomparison exercises were organized by the International Atomic Energy Agency (IAEA) on the determination of operational quantities at the regional or interregional basis. These exercises revealed significant differences in the approach, methods and assumptions, and consequently in the measurement results obtained by participating laboratories. In the East Asia region, the third phase of the Hp(10) intercomparison, organized within the frame of the Regional Cooperation Agreement (RCA) as a follow-up to previous exercises during 1990-92 and 1995-96, was completed mid-2004. The first phase grouped 25 laboratories from 16 member states, and 4 Secondary Standards Dosimetry Laboratories irradiated dosimeters in 6 different qualities for photon and beta radiations. In the second phase, 23 laboratories from 16 member states participated, and 3 Secondary Standards Dosimetry Laboratories provided irradiation in 5 different radiation qualities simulating workplace fields. The results of the second phase for the determination of operational quantities Hp(d) were satisfactory for all participating Member States, with marked improvement from the first phase; the laboratories demonstrated good performance in both quantities tested. These results underline the importance of such an intercomparison programme as a key element towards the harmonization of quantities and units on an international level. This paper presents the results of this RCA/IAEA intercomparison, and also the forthcoming RCA activities supporting intercomparison runs for the assessment of occupational exposure. Member states strongly recommend that the IAEA continue acting as a focal point for, inter alia, training in all forms, particularly in measurements and dosimetry techniques. This exercise also stressed the importance for the IAEA to take an active role in establishing a network of monitoring laboratories for radiation protection purposes, as it would provide for better information

  11. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact their dispatchers to explain their activities for the future, after LEP dismantling in order to be maintained on the regular distribution list at Individual DosimetryWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period MAY/JUNE will be available from their usual dispatchers on Tuesday 2 May.Please have your films changed before the 12 May.The colour of the dosimeter valid in is MAY/JUNE is YELLOW.Individual Dosimetry Service will be closed on Friday 28 April.

  12. Comparison between IAEA/TRS-277 and IAEA/TRS-398 protocols for electron beam dosimetry with cylindrical ionization chambers

    International Nuclear Information System (INIS)

    Souza, Roberto Salomon de

    2004-01-01

    With the purpose to guarantee an uncertainty in the dosimetry in radiation therapy, the International Atomic Energy Agency (IAEA) published in 1987 the Technical Reports Series (TRS) number 277 - Absorbed Dose Determination in Photon and Electron Beams - An International Code of Practice -, updated in 1997, when was published its second edition. In 2000 was published the TRS number 398 - Absorbed Dose Determination in External Beam Radiotherapy - An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. The TRS number 398 brings a great conceptual change in relation to the basis of the formalism, before based on calibration factor in terms of air kerma, and now based on calibration factor in terms of absorbed dose in water. Since the TRS number 398 was published, the Secondary Standard Dosimetry Laboratories are calibrating the user's ionization chambers in terms of absorbed dose to water. However, nor all the clinics in Rio de Janeiro and Brazil have its ionization chambers calibrated in terms of absorbed dose to water. The National Cancer Institute, where the measurements were taken, was the first institution in the Rio de Janeiro to have its ionization chambers calibrated in terms of a new formalism. This work describes a comparison between dosimetry done with a cylindrical ionization chamber under electron beams utilizing the TRS number 277 formalism, based on air kerma, and the TRS number 398 formalism, based on absorbed dose to water, reporting the uncertainties variation of the dosimetry associated to each protocol. (author)

  13. 77 FR 8902 - Draft Regulatory Guide: Issuance, Availability Decommissioning of Nuclear Power Reactors

    Science.gov (United States)

    2012-02-15

    ... Decommissioning of Nuclear Power Reactors AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide... draft regulatory guide (DG) DG-1271 ``Decommissioning of Nuclear Power Reactors.'' This guide describes... Regulatory Guide 1.184, ``Decommissioning of Nuclear Power Reactors,'' dated July 2000. This proposed...

  14. Dosimetry system of the RB reactor

    International Nuclear Information System (INIS)

    Lolic, B.; Vukadin, D.

    1962-01-01

    Although RB reactor is operated at very low power levels, safety and dosimetry systems have high importance. This paper shows detailed dosimetry system with fundamental typical components. Estimated radiation doses dependent on reactor power are given at some characteristic points in the rooms nearby reactor

  15. Experimental verification of internal dosimetry calculations. Annual progress report

    International Nuclear Information System (INIS)

    1980-05-01

    During the past year a dosimetry research program has been established in the School of Nuclear Engineering at the Georgia Institute of Technology. The major objective of this program has been to provide research results upon which a useful internal dosimetry system could be based. The important application of this dosimetry system will be the experimental verification of internal dosimetry calculations such as those published by the MIRD Committee

  16. Dosimetry: an ARDENT topic

    CERN Multimedia

    CERN Bulletin

    2012-01-01

    The first annual ARDENT workshop took place in Vienna from 20 to 23 November. The workshop gathered together the Early-Stage Researchers (ESR) and their supervisors, plus other people involved from all the participating institutions.   “The meeting, which was organised with the local support of the Austrian Institute of Technology, was a nice opportunity for the ESRs to get together, meet each other, and present their research plans and some preliminary results of their work,” says Marco Silari, a member of CERN Radiation Protection Group and the scientist in charge of the programme. Two full days were devoted to a training course on radiation dosimetry, delivered by renowned experts. The workshop closed with a half-day visit to the MedAustron facility in Wiener Neustadt. ARDENT (Advanced Radiation Dosimetry European Network Training) is a Marie Curie ITN project funded under EU FP7 with €4 million. The project focuses on radiation dosimetry exploiting se...

  17. Neutron dosimetry in biology

    International Nuclear Information System (INIS)

    Sigurbjoernsson, B.; Smith, H.H.; Gustafsson, A.

    1965-01-01

    To study adequately the biological effects of different energy neutrons it is necessary to have high-intensity sources which are not contaminated by other radiations, the most serious of which are gamma rays. An effective dosimetry must provide an accurate measure of the absorbed dose, in biological materials, of each type of radiation at any reactor facility involved in radiobiological research. A standardized biological dosimetry, in addition to physical and chemical methods, may be desirable. The ideal data needed to achieve a fully documented dosimetry has been compiled by H. Glubrecht: (1) Energy spectrum and intensity of neutrons; (2) Angular distribution of neutrons on the whole surface of the irradiated object; (3) Additional undesired radiation accompanying the neutrons; (4) Physical state and chemical composition of the irradiated object. It is not sufficient to note only an integral dose value (e.g. in 'rad') as the biological effect depends on the above data

  18. Regulatory Monitoring of Fortified Foods: Identifying Barriers and Good Practices

    Science.gov (United States)

    Rowe, Laura A; Vossenaar, Marieke; Garrett, Greg S

    2015-01-01

    While fortification of staple foods and condiments has gained enormous global traction, poor performance persists throughout many aspects of implementation, most notably around the critical element of regulatory monitoring, which is essential for ensuring foods meet national fortification standards. Where coverage of fortified foods is high, limited nutritional impact of fortification programs largely exists due to regulatory monitoring that insufficiently identifies and holds producers accountable for underfortified products. Based on quality assurance data from 20 national fortification programs in 12 countries, we estimate that less than half of the samples are adequately fortified against relevant national standards. In this paper, we outline key findings from a literature review, key informant interviews with 11 fortification experts, and semi-quantitative surveys with 39 individuals from regulatory agencies and the food fortification industry in 17 countries on the perceived effectiveness of regulatory monitoring systems and barriers to compliance against national fortification standards. Findings highlight that regulatory agencies and industry disagree on the value that enforcement mechanisms have in ensuring compliance against standards. Perceived political risk of enforcement and poorly resourced inspectorate capacity appear to adversely reinforce each other within an environment of unclear legislation to create a major hurdle for improving overall compliance of fortification programs against national standards. Budget constraints affect the ability of regulatory agencies to create a well-trained inspector cadre and improve the detection and enforcement of non-compliant and underfortified products. Recommendations to improve fortification compliance include improving technical capacity; ensuring sustained leadership, accountability, and funding in both the private and the public sectors; and removing political barriers to ensure consistent detection of

  19. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    International Nuclear Information System (INIS)

    Rathbone, Bruce A.

    2006-01-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL's Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL's Electronic Records & Information Capture Architecture (ERICA) database

  20. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2005-02-25

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database.

  1. Dosimetry techniques applied to thermoluminescent age estimation

    International Nuclear Information System (INIS)

    Erramli, H.

    1986-12-01

    The reliability and the ease of the field application of the measuring techniques of natural radioactivity dosimetry are studied. The natural radioactivity in minerals in composed of the internal dose deposited by alpha and beta radiations issued from the sample itself and the external dose deposited by gamma and cosmic radiations issued from the surroundings of the sample. Two technics for external dosimetry are examined in details. TL Dosimetry and field gamma dosimetry. Calibration and experimental conditions are presented. A new integrated dosimetric method for internal and external dose measure is proposed: the TL dosimeter is placed in the soil in exactly the same conditions as the sample ones, during a time long enough for the total dose evaluation [fr

  2. Report on high energy neutron dosimetry workshop

    International Nuclear Information System (INIS)

    Alvar, K.R.; Gavron, A.

    1993-01-01

    The workshop was called to assess the performance of neutron dosimetry per the responses from ten DOE accelerator facilities to an Office of Energy Research questionnaire regarding implementation of a personnel dosimetry requirement in DRAFT DOE 5480.ACC, ''Safety of Accelerator Facilities''. The goals of the workshop were to assess the state of dosimetry at high energy accelerators and if such dosimetry requires improvement, to reach consensus on how to proceed with such improvements. There were 22 attendees, from DOE Programs and contract facilities, DOE, Office of Energy Research (ER), Office of Environmental Safety and Health (EH), Office of Fusion Energy, and the DOE high energy accelerator facilities. A list of attendees and the meeting agenda are attached. Copies of the presentations are also attached

  3. Results from 2010 Caliban Criticality Dosimetry Intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K. G.

    2011-10-12

    The external dosimetry program participated in a criticality dosimetry intercomparison conducted at the Caliban facility in Valduc, France in 2010. Representatives from the dosimetry and instrumentation groups were present during testing which included irradiations of whole-body beta/gamma (HBGT) and neutron thermoluminescent dosimeters (TLDs), a fixed nuclear accident dosimeter (FNAD), electronic alarming dosimeters, and a humanoid phantom filled with reference man concentrations of sodium. This report reviews the testing procedures, preparations, irradiations, and presents results of the tests.

  4. Reactor Dosimetry State of the Art 2008

    Science.gov (United States)

    Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan

    2009-08-01

    Oral session 1: Retrospective dosimetry. Retrospective dosimetry of VVER 440 reactor pressure vessel at the 3rd unit of Dukovany NPP / M. Marek ... [et al.]. Retrospective dosimetry study at the RPV of NPP Greifswald unit 1 / J. Konheiser ... [et al.]. Test of prototype detector for retrospective neutron dosimetry of reactor internals and vessel / K. Hayashi ... [et al.]. Neutron doses to the concrete vessel and tendons of a magnox reactor using retrospective dosimetry / D. A. Allen ... [et al.]. A retrospective dosimetry feasibility study for Atucha I / J. Wagemans ... [et al.]. Retrospective reactor dosimetry with zirconium alloy samples in a PWR / L. R. Greenwood and J. P. Foster -- Oral session 2: Experimental techniques. Characterizing the Time-dependent components of reactor n/y environments / P. J. Griffin, S. M. Luker and A. J. Suo-Anttila. Measurements of the recoil-ion response of silicon carbide detectors to fast neutrons / F. H. Ruddy, J. G. Seidel and F. Franceschini. Measurement of the neutron spectrum of the HB-4 cold source at the high flux isotope reactor at Oak Ridge National Laboratory / J. L. Robertson and E. B. Iverson. Feasibility of cavity ring-down laser spectroscopy for dose rate monitoring on nuclear reactor / H. Tomita ... [et al.]. Measuring transistor damage factors in a non-stable defect environment / D. B. King ... [et al.]. Neutron-detection based monitoring of void effects in boiling water reactors / J. Loberg ... [et al.] -- Poster session 1: Power reactor surveillance, retrospective dosimetry, benchmarks and inter-comparisons, adjustment methods, experimental techniques, transport calculations. Improved diagnostics for analysis of a reactor pulse radiation environment / S. M. Luker ... [et al.]. Simulation of the response of silicon carbide fast neutron detectors / F. Franceschini, F. H. Ruddy and B. Petrović. NSV A-3: a computer code for least-squares adjustment of neutron spectra and measured dosimeter responses / J. G

  5. 78 FR 39284 - Technical Guidance for Assessing Environmental Justice in Regulatory Analysis

    Science.gov (United States)

    2013-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OA-2013-0320; FRL-9830-1] Technical Guidance for Assessing Environmental Justice in Regulatory Analysis AGENCY: Environmental Protection Agency (EPA). ACTION: Notice... Environmental Protection Agency (EPA) issued for public comment a document entitled, ``Technical Guidance for...

  6. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    CERN Document Server

    Cooper, J R

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  7. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    International Nuclear Information System (INIS)

    COOPER, J.R.

    2000-01-01

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual

  8. Hanford internal dosimetry program manual

    International Nuclear Information System (INIS)

    Carbaugh, E.H.; Sula, M.J.; Bihl, D.E.; Aldridge, T.L.

    1989-10-01

    This document describes the Hanford Internal Dosimetry program. Program Services include administrating the bioassay monitoring program, evaluating and documenting assessments of internal exposure and dose, ensuring that analytical laboratories conform to requirements, selecting and applying appropriate models and procedures for evaluating internal radionuclide deposition and the resulting dose, and technically guiding and supporting Hanford contractors in matters regarding internal dosimetry. 13 refs., 16 figs., 42 tabs

  9. Canadian and international approaches to regulatory effectiveness

    International Nuclear Information System (INIS)

    Lojk, R.

    2014-01-01

    Regulatory effectiveness is an important attribute of any regulator, particularly nuclear regulators. As the nuclear industry has matured, and as the social landscape has changed, so have views on what constitutes regulatory effectiveness. Canada has evolved its regulatory structure and modernized its legislative framework and technical requirements and guidance over time. In addition, Canada continues to collaborate with international agencies, particularly the NEA and the IAEA, to ensure that there is a common understanding of the indicators and key attributes of regulatory effectiveness. This paper discusses Canadian and international views on the subject, including perspectives from other industries. (author)

  10. Uncertainty analysis of dosimetry spectrum unfolding

    International Nuclear Information System (INIS)

    Perey, F.G.

    1977-01-01

    The propagation of uncertainties in the input data is analyzed for the usual dosimetry unfolding solution. A new formulation of the dosimetry unfolding problem is proposed in which the most likely value of the spectrum is obtained. The relationship of this solution to the usual one is discussed

  11. GENII: The Hanford Environmental Radiation Dosimetry Software System: Volume 2, Users' manual: Hanford Environmental Dosimetry Upgrade Project

    International Nuclear Information System (INIS)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-11-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). The purpose of this coupled system of computer codes is to analyze environmental contamination of, air, water, or soil. This is accomplished by calculating radiation doses to individuals or populations. GENII is described in three volumes of documentation. This second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. The first volume describes the theoretical considerations of the system. The third volume is a Code Maintenance Manual for the user who requires knowledge of code detail. It includes logic diagrams, global dictionary, worksheets, example hand calculations, and listings of the code and its associated data libraries. 27 refs., 17 figs., 23 tabs

  12. O lugar da política na atuação das agências reguladoras independentes brasileiras: reflexões sobre a separação dos poderes no Estado moderno / The Role of Politics in the Brazilian Independent Regulatory Agencies: Reflections on the Separation of Powers in the Modern State

    Directory of Open Access Journals (Sweden)

    Milton Carvalho Gomes

    2017-04-01

    Full Text Available Purpose – The purpose of the proposed article is to investigate the practice of politics in the performance of activities of Brazilian independent regulatory agencies Methodology/approach/design – ... The approach is based on the study of theories about separation of state powers and functions, evaluating the application of these theories in the understanding of the role played by independent regulatory agencies in Brazil Findings – It was concluded that the independence granted by the National Congress to the Brazilian regulatory agencies implied in the expansion of the space of politics in its operation, placing these agencies in a unique position in the context of the separation of powers, changing the traditional institutional arrangement of submission to the executive branch. Practical implications (if applicable –The conclusions permit new reflections on the limits of the influence of the President of the Republic and of the sectoral ministries in the decisions taken by the regulatory agencies, both in the decisions of a technical nature and those of a political nature, allowing the expansion of the debate on the instruments of democratic legitimation of these decisions. Originality/value (optional – The text is original, since there are few in-depth studies in Brazil about the space for politics in the field of independent regulatory agencies, usually understood as purely technical / administrative entities.

  13. Technical Basis Document for PFP Area Monitoring Dosimetry Program

    Energy Technology Data Exchange (ETDEWEB)

    COOPER, J.R.

    2000-04-17

    This document describes the phantom dosimetry used for the PFP Area Monitoring program and establishes the basis for the Plutonium Finishing Plant's (PFP) area monitoring dosimetry program in accordance with the following requirements: Title 10, Code of Federal Regulations (CFR), part 835, ''Occupational Radiation Protection'' Part 835.403; Hanford Site Radiological Control Manual (HSRCM-1), Part 514; HNF-PRO-382, Area Dosimetry Program; and PNL-MA-842, Hanford External Dosimetry Technical Basis Manual.

  14. Introduction to radiological physics and radiation dosimetry

    CERN Document Server

    Attix, Frank Herbert

    2004-01-01

    A straightforward presentation of the broad concepts underlying radiological physics and radiation dosimetry for the graduate-level student. Covers photon and neutron attenuation, radiation and charged particle equilibrium, interactions of photons and charged particles with matter, radiotherapy dosimetry, as well as photographic, calorimetric, chemical, and thermoluminescence dosimetry. Includes many new derivations, such as Kramers X-ray spectrum, as well as topics that have not been thoroughly analyzed in other texts, such as broad-beam attenuation and geometrics, and the reciprocity theorem

  15. Sixth international radiopharmaceutical dosimetry symposium: Proceedings. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    S.-Stelson, A.T. [ed.] [comp.; Stabin, M.G.; Sparks, R.B. [eds.; Smith, F.B. [comp.

    1999-01-01

    This conference was held May 7--10 in Gatlinburg, Tennessee. The purpose of this conference was to provide a multidisciplinary forum for exchange of state-of-the-art information on radiopharmaceutical dosimetry. Attention is focused on the following: quantitative analysis and treatment planning; cellular and small-scale dosimetry; dosimetric models; radiopharmaceutical kinetics and dosimetry; and animal models, extrapolation, and uncertainty.

  16. 21 CFR 312.86 - Focused FDA regulatory research.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Focused FDA regulatory research. 312.86 Section 312.86 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Severely-debilitating Illnesses § 312.86 Focused FDA regulatory research. At the discretion of the agency...

  17. Regulatory framework for the management of radioactive wastes in Argentina

    International Nuclear Information System (INIS)

    D'Amato, E.; Siraky, G.; Petraitis, E.; Novo, R.

    2000-01-01

    The legal and regulatory framework within which the radioactive waste management is carried out in Argentina are exposed. The activities of the Nuclear Regulatory Authority (ARN) in relation to facility inspections, safety assessments and collaboration with international agencies in the matter are also presented. Further, the regulatory criteria applied to waste management are reported. (author)

  18. Effective and independent regulatory national infrastructure: Uruguay case

    International Nuclear Information System (INIS)

    Nader, A.V.

    2003-01-01

    Since inception in 1986 the National Direction of Nuclear Technology has fulfilled with the assignment known as 'Control of the ionizing radioactivity in its medical and industrial applications'. This strategic task as far as safety, was performed with significant and crucial deficiencies which they even motivated the users to question the reliability of the institution. The deficiencies were mainly as follows: 1) absence of a regulatory frame; 2) insufficient qualification of technical human resources and 3) lack of suitable equipment. From the use for Uruguay of the Model Project and the beginning of a new management of Dinaten (October 2000), a sensible and well-known increase in the quality and efficiency of the regulating function in the country, which we can summarize in the following landmarks: regulatory frame with the use of a basic norm and eight regulating norms according to the main practices that are developed in the country; intensive training of the regulatory body staff; permanent accomplished update of the inventory of sources; beginning of licensing activities; equipment of last generation; regulation of the personal dosimetry services and management of radioactive waste and establishment of a National Program of Radiological Emergencies. (author)

  19. Electricity and telecommunications regulatory institutions in small and developing countries

    Energy Technology Data Exchange (ETDEWEB)

    Stern, J. [London Business School, London (United Kingdom)

    2000-09-01

    The spread of utility liberalisation and privatisation to middle and low income developing countries raises the problem of whether and how they can establish an effective regulatory capability of whether the supply of regulatory services is likely to be insufficient. The paper presents evidence on the size of electricity regulatory agencies in 24 mainly middle and lower income countries as well as the number of high-level, specialist regulatory staff and the potential resource pool from post-school education. The paper also discusses how far the problem can be alleviated and/or avoided by the use of regulation by contract, regulation by multi-national regulatory agency or contracting-out. The paper concludes that such solutions are unlikely to be generally effective but that informal exchanges of information and pooling of resources between national regulators on a market-driven basis, as seen in Southern Africa and the EU, is a promising option. The paper concludes by pointing to the need to ascertain the minimum required regulatory capability in developing countries as perceived by Governments and potential investors. (author)

  20. Proceedings of the recent developments in radiation dosimetry

    International Nuclear Information System (INIS)

    Bhat, Nagesh; Palani Selvan, T.

    2016-01-01

    Whilst 'Dosimetry' in its original sense deals with methods for a quantitative determination of energy deposited in a given medium by directly or indirectly ionizing radiations, the term is better known as a scientific sub-specialty in the fields of health physics and medical physics, where it is the calculation and assessment of the radiation dose received by the human body. Dosimetry is used extensively for radiation protection and is routinely applied to ensure radiological safety of occupational radiation workers. Internal dosimetry due to the ingestion or inhalation of radioactive materials relies on a variety of physiological or imaging techniques. External dosimetry, due to irradiation from an external source is based on measurements with a dosimeter, or inferred from other radiological protection instruments. Radiation dosimetry is one of the important research areas of Department of Atomic Energy (DAE). This research work is centered on the facilities such as nuclear reactors, reprocessing plants, high energy accelerators (research/industry/medical), radiation standards, food processing, radiation technology development, etc. In each of these facilities, radiation field environment is different and the associated dosimetry concepts are different. Papers relevant to INIS are indexed separately

  1. Quality assurance in personal dosimetry of external radiation: present situation and future needs

    International Nuclear Information System (INIS)

    Ma, N.

    2006-01-01

    Whole body personal dosimetry is well established for the individual monitoring of radiation workers. High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The mandate has been given to the Personal Dosimetry, (secondary standard dosimetry laboratories) S.S.D.L., (Malaysian institute for nuclear energy research) M.I.N.T. to assure the individual monitoring for radiation workers in Malaysia. In 2005, the S.S.D.L;-M.I.N.T. supply, process and read out of personal dosemeters of nearly 13,000 dosimeters monthly, whereby. 12,000 are films and 1,000 are T.L.D.s. The objective of individual monitoring is not limited to the measurement of doses delivered to individuals, but it should demonstrate that limits of exposure have not been exceeded and that working conditions have not unexpectedly deteriorated. Dosimetry measurements are an important component of radiation protection programs and must be of high quality. The exposure of workers to radiation must be controlled and monitored in order to comply with regulatory requirements. S.S.D.L.-M.I.N.T; demonstrates that its performance is at an acceptable level by implementing overall system performance, as evidenced by the ISO 9001 certification of the Personal Dosimetry Service in 2002 and ISO/I.E.C. 17025 accreditation to the calibration laboratory in 2004. The certification and accreditation processes achieved the goal by formalizing the recognition of satisfactory performance, and providing evidence of this performance. Overall performances are assessed, personnel operating the system will be trained and are well qualified and all actions will be documented. The paper describes the overview of the Q.M.S. carried out at the S.S. D.L.-M.I.N.T.. During the implementation of Q.M.S. a few areas has been identified for future consideration. These include performance specification and type testing of dosemeters, which provide a

  2. Regulatory practices and safety standards for nuclear power plants

    International Nuclear Information System (INIS)

    1989-01-01

    The International Symposium on Regulatory Practices and Safety Standards for Nuclear Power Plants was jointly organized by the International Atomic Energy Agency (IAEA), for Nuclear Energy Agency of the OECD and the Government of the Federal Republic of Germany with the objective of providing an international forum for the exchange of information on regulatory practices and safety standards for nuclear power plants. The Symposium was held in Munich, Federal Republic of Germany, from 7 to 10 November 1988. It was attended by 201 experts from some 32 Member States and 4 international organizations. Fifty-one papers from 19 Member States and 2 international organizations were presented and discussed in 5 technical sessions covering the following subjects: National Regulatory Practices and Safety Standards (14 papers); Implementation of Regulatory Practices - Technical Issues (8 papers); Implementation of Regulatory Practices - Operational Aspects (8 papers); Developments and Trends in Safety Standards and Practices (11 papers); International Aspects (10 papers). A separate abstract was prepared for each of these papers. Refs, figs and tabs

  3. 76 FR 7762 - Drinking Water: Regulatory Determination on Perchlorate

    Science.gov (United States)

    2011-02-11

    ...-9262-8] RIN 2040-AF08 Drinking Water: Regulatory Determination on Perchlorate AGENCY: Environmental...'s) regulatory determination for perchlorate in accordance with the Safe Drinking Water Act (SDWA... substantial likelihood that perchlorate will occur in public water systems with a frequency and at levels of...

  4. Formal independence of regulatory agencies and Varieties of Capitalism

    DEFF Research Database (Denmark)

    Guardiancich, Igor; Guidi, Mattia

    2016-01-01

    The Varieties of Capitalism literature posits that national economic institutions reflect the mode of coordination of a country’s market actors. Despite the importance of this claim and a rich literature on the emergence of regulatory capitalism, few studies test such prediction for Independent...

  5. Glass badge dosimetry system for large scale personal monitoring

    International Nuclear Information System (INIS)

    Norimichi Juto

    2002-01-01

    Glass Badge using silver activated phosphate glass dosemeter was specially developed for large scale personal monitoring. And dosimetry systems such as an automatic leader and a dose equipment calculation algorithm were developed at once to achieve reasonable personal monitoring. In large scale personal monitoring, both of precision for dosimetry and confidence for lot of personal data handling become very important. The silver activated phosphate glass dosemeter has basically excellent characteristics for dosimetry such as homogeneous and stable sensitivity, negligible fading and so on. Glass Badge was designed to measure 10 keV - 10 MeV range of photon. 300 keV - 3 MeV range of beta, and 0.025 eV - 15 MeV range of neutron by included SSNTD. And developed Glass Badge dosimetry system has not only these basic characteristics but also lot of features to keep good precision for dosimetry and data handling. In this presentation, features of Glass Badge dosimetry systems and examples for practical personal monitoring systems will be presented. (Author)

  6. Environmental sciences division: Environmental regulatory update table July 1988

    International Nuclear Information System (INIS)

    Langston, M.E.; Nikbakht, A.; Salk, M.S.

    1988-08-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated each month with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action

  7. Environmental Regulatory Update Table, March/April 1993. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Salk, M.S.; Danford, G.S.; Lewis, E.B.

    1993-05-01

    The Environmental Regulatory Update Table provides information on regulatory initiatives of interest to DOE operations and contractor staff with environmental management responsibilities. The table is updated bimonthly with information from the Federal Register and other sources, including direct contact with regulatory agencies. Each table entry provides a chronological record of the rulemaking process for that initiative with an abstract and a projection of further action.

  8. A-bomb survivor dosimetry update

    International Nuclear Information System (INIS)

    Loewe, W.E.

    1982-06-01

    A-bomb survivor data have been generally accepted as applicable. Also, the initial radiations have tended to be accepted as the dominant radiation source for all survivors. There was general acceptance of the essential reliability of both the biological effects data and the causative radiation dose values. There are considerations casting doubt on these acceptances, but very little quantification of th implied uncertainties has been attempted. The exception was A-bomb survivor dosimetry, where free-field kerma values for initial radiations were thought to be accurate to about 30%, and doses to individual survivors were treated as effectively error-free. In 1980, a major challenge to the accepted A-bomb survivor dosimetry was announced, and was quickly followed by a succession of explanations and displays showing the soundness of that challenge. In fact, a complete replacement set of free-field kerma values was provided which was suitable for use in constructing an entire new dosimetry for Hiroshima and Nagasaki. The new values showed many changes greater than the accepted 30% uncertainty. An approximate new dosimetry was indeed constructed, and used to convert existing leukemia cause-and-effect data from the old to the new dose values, by way of assessing the impact

  9. Nuclear regulatory decision making

    International Nuclear Information System (INIS)

    2005-01-01

    The fundamental objective of all nuclear safety regulatory bodies is to ensure that nuclear utilities operate their plants at all times in an acceptably safe manner. In meeting this objective, the regulatory body should strive to ensure that its regulatory decisions are technically sound, consistent from case to case, and timely. In addition, the regulator must be aware that its decisions and the circumstances surrounding those decisions can affect how its stakeholders, such as government policy makers, the industry it regulates, and the public, view it as an effective and credible regulator. In order to maintain the confidence of those stakeholders, the regulator should make sure that its decisions are transparent, have a clear basis in law and regulations, and are seen by impartial observers to be fair to all parties. Based on the work of a Nuclear Energy Agency (NEA) expert group, this report discusses some of the basic principles and criteria that a regulatory body should consider in making decisions and describes the elements of an integrated framework for regulatory decision making. (author)

  10. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    Standardized Physics-Dosimetry procedures and data are being developed and tested for monitoring the neutron doses accumulated by reactor pressure vessels (PV) and their support structures. These procedures and data are governed by a set of 21 ASTM standard practices, guides, and methods for the prediction of neutron-induced changes in light water reactor (LWR) PVs and support structure steels throughout the service life of the PV. This paper summarizes the applications of these standards to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and deployment of advanced dosimetry sets for commercial reactors is also summarized

  11. Cellular dosimetry in nuclear medicine imaging: training

    International Nuclear Information System (INIS)

    Gardin, I.; Faraggi, M.; Stievenart, J.L.; Le Guludec, D.; Bok, B.

    1998-01-01

    The radionuclides used in nuclear medicine imaging emit not only diagnostically useful photons, but also energy electron emissions, responsible for dose heterogeneity at the cellular level. The mean dose delivered to the cell nucleus by electron emissions of 99m Tc, 123 I, 111 In, 67 Ga, and 201 Tl, has been calculated, for the cell nucleus, a cytoplasmic and a cell membrane distribution of radioactivity. This model takes into account both the self-dose which results from the radionuclide located in the target cell, and the cross-dose, which comes from the surrounding cells. The results obtained by cellular dosimetry (D cel ) have been compared with those obtained with conventional dosimetry (D conv ), by assuming the same amount of radioactivity per cell. Cellular dosimetry shows, for a cytoplasmic and a cell membrane distributions of radioactivity, that the main contribution to the dose to the cell nucleus, comes from the surrounding cells. On the other hand, for a cell nucleus distribution of radioactivity, the self-dose is not negligible and may be the main contribution. The comparison between cellular and conventional dosimetry shows that D cel /D conv ratio ranges from 0.61 and O.89, in case of a cytoplasmic and a cell membrane distributions of radioactivity, depending on the radionuclide and cell dimensions. Thus, conventional dosimetry slightly overestimates the mean dose to the cell nucleus. On the other hand, D cel /D conv ranges from 1.1 to 75, in case of a cell nucleus distribution of radioactivity. Conventional dosimetry may strongly underestimates the absorbed dose to the nucleus, when radioactivity is located in the nucleus. The study indicates that in nuclear medicine imaging, cellular dosimetry may lead to a better understanding of biological effects of radiopharmaceuticals. (authors)

  12. 78 FR 54517 - Water Quality Standards Regulatory Clarifications

    Science.gov (United States)

    2013-09-04

    ... 131 Water Quality Standards Regulatory Clarifications; Proposed Rule #0;#0;Federal Register / Vol. 78... AGENCY 40 CFR Part 131 [EPA-HQ-OW-2010-0606; FRL-9839-7] RIN 2040-AF 16 Water Quality Standards... Environmental Protection Agency (EPA) is proposing changes to the federal water quality standards (WQS...

  13. Dosimetry in life sciences

    International Nuclear Information System (INIS)

    1975-01-01

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  14. Dosimetry in life sciences

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-06-15

    The uses of radiation in medicine and biology have grown in scope and diversity to make the Radiological Sciences a significant factor in both research and medical practice. Of critical importance in the applications and development of biomedical and radiological techniques is the precision with which the dose may be determined at all points of interest in the absorbing medium. This has developed as a result of efficacy of investigations in clinical radiation therapy, concern for patient safety and diagnostic accuracy in diagnostic radiology and the advent of clinical trials and research into the use of heavily ionizing radiations in biology and medicine. Since the last IAEA Symposium on Dosimetry Techniques applied to Agriculture, Industry, Biology and Medicine, held in Vienna in 1972, it has become increasingly clear that advances in the techniques and hardware of biomedical dosimetry have been rapid. It is for these reasons that this symposium was organized in a concerted effort to focus on the problems, developments and areas of further research in dosimetry in the Life Sciences. (author)

  15. Validating dose rate calibration of radiotherapy photon beams through IAEA/WHO postal audit dosimetry service

    International Nuclear Information System (INIS)

    Jangda, A.Q.; Hussein, S.

    2012-01-01

    In external beam radiation therapy (EBRT), the quality assurance (QA) of the radiation beam is crucial to the accurate delivery of the prescribed dose to the patient. One of the dosimetric parameters that require monitoring is the beam output, specified as the dose rate on the central axis under reference conditions. The aim of this project was to validate dose rate calibration of megavoltage photon beams using the International Atomic Energy Agency (IAEA)/World Health Organisation (WHO) postal audit dosimetry service. Three photon beams were audited: a 6 MV beam from the low-energy linac and 6 and 18 MV beams from a dual high-energy linac. The agreement between our stated doses and the IAEA results was within 1% for the two 6 MV beams and within 2% for the 18 MV beam. The IAEA/WHO postal audit dosimetry service provides an independent verification of dose rate calibration protocol by an international facility. (author)

  16. Validating dose rate calibration of radiotherapy photon beams through IAEA/WHO postal audit dosimetry service.

    Science.gov (United States)

    Jangda, Abdul Qadir; Hussein, Sherali

    2012-05-01

    In external beam radiation therapy (EBRT), the quality assurance (QA) of the radiation beam is crucial to the accurate delivery of the prescribed dose to the patient. One of the dosimetric parameters that require monitoring is the beam output, specified as the dose rate on the central axis under reference conditions. The aim of this project was to validate dose rate calibration of megavoltage photon beams using the International Atomic Energy Agency (IAEA)/World Health Organisation (WHO) postal audit dosimetry service. Three photon beams were audited: a 6 MV beam from the low-energy linac and 6 and 18 MV beams from a dual high-energy linac. The agreement between our stated doses and the IAEA results was within 1% for the two 6 MV beams and within 2% for the 18 MV beam. The IAEA/WHO postal audit dosimetry service provides an independent verification of dose rate calibration protocol by an international facility.

  17. 3D dosimetry by optical-CT scanning

    Science.gov (United States)

    Oldham, Mark

    2006-12-01

    The need for an accurate, practical, low-cost 3D dosimetry system is becoming ever more critical as modern dose delivery techniques increase in complexity and sophistication. A recent report from the Radiological Physics Center (RPC) (1), revealed that 38% of institutions failed the head-and-neck IMRT phantom credentialing test at the first attempt. This was despite generous passing criteria (within 7% dose-difference or 4mm distance-to-agreement) evaluated at a half-dozen points and a single axial plane. The question that arises from this disturbing finding is - what percentage of institutions would have failed if a comprehensive 3D measurement had been feasible, rather than measurements restricted to the central film-plane and TLD points? This question can only be adequately answered by a comprehensive 3D-dosimetry system, which presents a compelling argument for its development as a clinically viable low cost dosimetry solution. Optical-CT dosimetry is perhaps the closest system to providing such a comprehensive solution. In this article, we review the origins and recent developments of optical-CT dosimetry systems. The principle focus is on first generation systems known to have highest accuracy but longer scan times.

  18. Thermoluminescent measurement in space radiation dosimetry

    International Nuclear Information System (INIS)

    Chen Mei; Qi Zhangnian; Li Xianggao; Huang Zengxin; Jia Xianghong; Wang Genliang

    1999-01-01

    The author introduced the space radiation environment and the application of thermoluminescent measurement in space radiation dosimetry. Space ionization radiation is charged particles radiation. Space radiation dosimetry was developed for protecting astronauts against space radiation. Thermoluminescent measurement is an excellent method used in the spaceship cabin. Also the authors mentioned the recent works here

  19. Fifth international radiopharmaceutical dosimetry symposium

    International Nuclear Information System (INIS)

    Watson, E.E.; Schlafke-Stelson, A.T.

    1992-05-01

    This meeting was held to exchange information on how to get better estimates of the radiation absorbed dose. There seems to be a high interest of late in patient dosimetry; discussions were held in the light of revised risk estimates for radiation. Topics included: Strategies of Dose Assessment; Dose Estimation for Radioimmunotherapy; Dose Calculation Techniques and Models; Dose Estimation for Positron Emission Tomography (PET); Kinetics for Dose Estimation; and Small Scale Dosimetry and Microdosimetry. (VC)

  20. Dosimetry on the radiological risks prevention in radiotherapy

    International Nuclear Information System (INIS)

    Fornet R, O. M.; Perez G, F.

    2014-08-01

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  1. 78 FR 70354 - Conceptual Example of a Proposed Risk Management Regulatory Framework Policy Statement

    Science.gov (United States)

    2013-11-25

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0254] Conceptual Example of a Proposed Risk Management Regulatory Framework Policy Statement AGENCY: Nuclear Regulatory Commission. ACTION: Conceptual example of a... ``openness,'' a white paper on a Conceptual Example of a Proposed Risk Management Regulatory Framework (RMRF...

  2. Dosimetry in support of wholesomeness studies

    International Nuclear Information System (INIS)

    Jarrett, R.D.; Halliday, J.W.

    1979-01-01

    Interest in dosimetry procedures in the context of a large-scale processing situation exceeds the purely documentary aspects of this report. The numerous combinations afforded by the various types, strengths and configurations of irradiation sources and the possibilities for various conveyors and other facility design factors impacting on irradiation logistics render a completely general treatment of dosimetry procedures in such instances almost impossible. While the exact combination of these various factors represented by the irradiation facilities at NARADCOM may be duplicated nowhere else, the dosimetry procedures documented in this report offer both experience and solutions that might be more generally useful. Therefore, this report complements and supplements more general discussions found in the literature and cited in the text

  3. Radiation dosimetry activities in the Netherlands

    International Nuclear Information System (INIS)

    Broerse, J.J.; Mijnheer, B.J.

    1986-07-01

    The Netherlands Commission for Radiation Dosimetry (NCS) was officially established on 3 September 1982 with the aim of promoting the appropriate use of dosimetry of ionizing radiation both for scientific research and practical applications. The present report provides a compilation of the dosimetry acitivities and expertise available in the Netherlands, based on the replies to a questionnaire mailed under the auspices of the NCS and might suffer from some incompleteness in specific details. The addresses of the Dutch groups with the names of the scientists are given. Individual scientists, not connected with a scientific group, hospital or organization have not been included in this list. Also the names of commercial firms producing dosimetric systems have been omitted. (Auth.)

  4. The Australian radiation protection and Nuclear Safety Agency

    International Nuclear Information System (INIS)

    Macnab, D.; Burn, P.; Rubendra, R.

    1998-01-01

    The author talks about the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), the new regulatory authority which will combine the existing resources of the Australian Radiation Laboratory and the Nuclear Safety Bureau. Most uses of radiation in Australia are regulated by State or Territory authorities, but there is presently no regulatory authority for Commonwealth uses of radiation. To provide for regulation of the radiation practices of the Commonwealth, the Australian Government has decided to establish the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) and a Bill has passed through the House of Representatives and will go to the Spring sitting of the Senate. The new agency will subsume the resources and functions of the Nuclear Safety Bureau and the Australian Radiation Laboratory, with additional functions including the regulation of radiation protection and nuclear safety of Commonwealth practices. Another function of ARPANSA will be the promotion of uniform regulatory requirements for radiation protection across Australia. This will be done by developing, in consultation with the States and Territories, radiation health policies and practices for adoption by the Commonwealth, States and Territories. ARPANSA will also provide research and services for radiation health, and in support of the regulatory and uniformity functions. The establishment of ARPANSA will ensure that the proposed replacement research reactor, the future low level radioactive waste repository and other Commonwealth nuclear facilities and radiation practices are subject to a regulatory regime which reflects the accumulated experience of the States and Territories and best international practice, and meets public expectations

  5. Fast neutron dosimetry and spectrometry using radioactivation (1963); Dosimetrie et spectrometrie des neutrons rapides par radioactivation (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Lamberieux, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The author first recalls rapidly a few generalities concerning induced radioactivity detectors and gives, in an appendix, tables summarizing the properties of detector elements which may be used in radioprotection. The excitation functions found in the literature and also given. The technological characteristics of the detectors used are given, together with the counting methods. The many advantages of activation dosimetry for strong or periodic neutron fluxes and for those in the presence of {gamma}-radiation are stressed. The main problem in activation dosimetry is, however, the calculation of the dose absorbed from the results of the measurements. It is shown how the dose is expressed, fairly accurately, as a function of the radioactivities induced in a series of detectors. As an example, the spectrometry and the dosimetry of the neutron flux emitted by a Po-Be source are presented. (author) [French] L'auteur fait d'abord un bref rappel des generalites sur les detecteurs a radioactivite induite, accompagne, en annexe, des tableaux resumant les proprietes d'elements detecteurs utilisables en radioprotection. Les fonctions d'excitation trouvees dans la litterature y sont egalement annexees. On donne ensuite les caracteristiques technologiques des detecteurs employes ainsi que les methodes de comptage utilisees. On souligne les nombreux avantages de la dosimetrie par activation dans les flux de neutrons intenses ou periodiques et en presence de rayonnement {gamma}. Il reste que le probleme central de la dosimetrie par activation est le calcul de la dose absorbee a partir des resultats de mesure. On montre comment la dose s'exprime, de maniere approchee, en fonction des radioactivites induites dans une serie de detecteurs. A titre d'exemple, la spectrometrie et la dosimetrie du flux de neutrons emis par une source de Po-Be sont presentees. (auteur)

  6. Radiation protection dosimetry in medicine - Report of the working group n.9 of the European radiation dosimetry group (EURADOS) - coordinated network for radiation dosimetry (CONRAD - contract EC N) fp6-12684

    International Nuclear Information System (INIS)

    2009-01-01

    This report present the results achieved within the frame of the work the WP 7 (Radiation Protection Dosimetry of Medical Staff) of the coordination action CONRAD (Coordinated Network for Radiation Dosimetry) funded through the 6. EU Framework Program. This action was coordinated by EURADOS (European Radiation Dosimetry Group). EURADOS is an organization founded in 1981 to advance the scientific understanding and the technical development of the dosimetry of ionising radiation in the fields of radiation protection, radiobiology, radiation therapy and medical diagnosis by promoting collaboration between European laboratories. WP7 coordinates and promotes European research for the assessment of occupational exposures to staff in therapeutic and diagnostic radiology workplaces. Research is coordinated through sub-groups covering three specific areas: 1. Extremity dosimetry in nuclear medicine and interventional radiology: this sub-group coordinates investigations in the specific fields of the hospitals and studies of doses to different parts of the hands, arms, legs and feet; 2. Practice of double dosimetry: this sub-group reviews and evaluates the different methods and algorithms for the use of dosemeters placed above and below lead aprons in large exposure during interventional radiology procedures, especially to determine effective doses to cardiologists during cardiac catheterization; and 3. Use of electronic personal dosemeters in interventional radiology: this sub-group coordinates investigations in laboratories and hospitals, and intercomparisons with passive dosemeters with the aim to enable the formulation of standards. (authors)

  7. Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing. 2. ed.

    International Nuclear Information System (INIS)

    2002-01-01

    This practice covers dosimetric procedures to be followed in facility characterization, process qualification, and routine processing using X rays (bremsstrahlung) to ensure that the entire product has been treated within an acceptable range of absorbed doses. Other procedures related to facility characterization, process qualification, and routine processing that may influence absorbed dose in the product are also discussed. The establishment of effective or regulatory dose and X-ray energy limits are not within the scope of this practice. In contrast to monoenergetic gamma rays, the bremsstrahlung energy spectrum extends from low values up to the maximum energy of the electrons incident on the X-ray target (see Section 5 and Annex A1). Dosimetry is only one component of a total quality assurance program for an irradiation facility. Other controls besides dosimetry may be required for specific applications such as medical device sterilization and food preservation. For the irradiation of food and the radiation sterilization of health care products, other specific ISO standards exist. For food irradiation, see ISO/ASTM Practice 51431. For the radiation sterilization of health care products, see ISO 11137:1995. In those areas covered by ISO 11137, that standard takes precedence

  8. Dosimetry of high energy radiation

    CERN Document Server

    Sahare, P D

    2018-01-01

    High energy radiation is hazardous to living beings and a threat to mankind. The correct estimation of the high energy radiation is a must and a single technique may not be very successful. The process of estimating the dose (the absorbed energy that could cause damages) is called dosimetry. This book covers the basic technical knowledge in the field of radiation dosimetry. It also makes readers aware of the dangers and hazards of high energy radiation.

  9. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2009-08-28

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document.

  10. External audit in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Thwaites, D.I.; Western General Hospital, Edinburgh

    1996-01-01

    Quality audit forms an essential part of any comprehensive quality assurance programme. This is true in radiotherapy generally and in specific areas such as radiotherapy dosimetry. Quality audit can independently test the effectiveness of the quality system and in so doing can identify problem areas and minimize their possible consequences. Some general points concerning quality audit applied to radiotherapy are followed by specific discussion of its practical role in radiotherapy dosimetry, following its evolution from dosimetric intercomparison exercises to routine measurement-based on-going audit in the various developing audit networks both in the UK and internationally. Specific examples of methods and results are given from some of these, including the Scottish+ audit group. Quality audit in radiotherapy dosimetry is now well proven and participation by individual centres is strongly recommended. Similar audit approaches are to be encouraged in other areas of the radiotherapy process. (author)

  11. The role of Polish Secondary Standard Dosimetry Laboratory in view of the requirements of the EC Directive 97/43 EURATOM

    International Nuclear Information System (INIS)

    Gwiazdowska, B.; Bulski, W.

    2004-01-01

    The aim of this paper is to present the history and experience of the Polish SSDL (Secondary Standard Dosimetry Laboratory). It also presents the propositions in the domain of quality assurance in radiotherapy in Poland, as fulfilling the requirements of the Directive 97/43 EURATOM on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure, which is obligatory for the countries of the European Union. It has been pointed out that there are, among other provisions, two concepts concerning the quality assurance in application of radiation in medicine, mentioned by the Directive, a) inspection and b) clinical audit, which should be implemented by the Member States. In the process of establishing and implementing the Directive confusion may appear as to the difference between the two concepts of external audits. The role of the SSDLs in carrying out external dosimetry audits is presented. The history of the establishment of the Polish SSDL (Secondary Standard Dosimetry Laboratory) and its inclusion into the international network of laboratories coordinated by the International Atomic Energy Agency and the World Health Organization is presented as well as the resulting advantages, obligations and perspectives for further activities. The main activities of the Polish have been presented, namely maintaining a data-base on the radiotherapy infrastructure in Poland, preparation of recommendations on dosimetry procedures and quality control, calibration of dosimeters, external postal quality audits of dosimetry, etc. These activities are illustrated with the results from the period 1991-2003. Based on the solutions and results presented in this paper, the authors conclude that the Ministry of Health should grant the Polish SSDL with a suitable legal status for carrying out external audits nationwide, especially since, according to the Directive 97/43, clinical audits in radiotherapy have to include dosimetry audits. (author)

  12. 76 FR 411 - Regulatory Guidance Concerning Electronic Signatures and Documents

    Science.gov (United States)

    2011-01-04

    ... guidance, including memoranda and letters, may no longer be relied upon to the extent they are inconsistent... Concerning Electronic Signatures and Documents AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice of regulatory guidance. SUMMARY: FMCSA issues regulatory guidance concerning the...

  13. Recent progress in application of JAERI alanine/ESR dosimetry system

    International Nuclear Information System (INIS)

    Kojima, T.

    1995-01-01

    Feasibility studies of application of JAERI alanine/ESR dosimetry system were performed on radiotherapy level dosimetry, low dose-rate dosimetry for residual life estimation of cable insulators used in nuclear power facilities, and dose monitoring for electron processing. (author)

  14. 10 CFR 835.1304 - Nuclear accident dosimetry.

    Science.gov (United States)

    2010-01-01

    ...) Methods and equipment for analysis of biological materials; (3) A system of fixed nuclear accident... Nuclear accident dosimetry. (a) Installations possessing sufficient quantities of fissile material to... 10 Energy 4 2010-01-01 2010-01-01 false Nuclear accident dosimetry. 835.1304 Section 835.1304...

  15. Mixed field dosimetry with paired ionization chambers

    International Nuclear Information System (INIS)

    Coppola, M.; Porro, F.

    1977-01-01

    This report describes the results of neutron and gamma mixed-field dosimetry obtained by the Ispra Group in the framework of the European Neutron Dosimetry intercomparison Project (ENDIP). The experimental method and the formulation employed for the derivation of Kerma results are also present

  16. Mobile Source Emissions Regulatory Compliance Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Mobile Source Emissions Regulatory Compliance Data Inventory data asset contains measured summary compliance information on light-duty, heavy-duty, and non-road...

  17. Dosimetry. Standard practice for dosimetry in gamma irradiation facilities for food and non-food processing

    International Nuclear Information System (INIS)

    2008-01-01

    This Ghana Standard outlines the installation qualification program for an irradiator and the dosimetry procedures to be followed during operational qualification, performance qualification and routine processing in facilities that process food and non-food with gamma rays. This is to ensure that the product has been treated with predetermined range of absorbed dose. It is not intended for use in X-ray and electron beam facilities and therefore dosimetry systems in such facilities are not covered

  18. Alanine-ESR dosimetry for radiotherapy IAEA experience

    International Nuclear Information System (INIS)

    Mehta, K.; Girzikowsky, R.; )

    1997-01-01

    At present, the most commonly used transfer dosimeters for radiotherapy applications are TL dosemeters. They are being used for intercomparison between SSDLs (about 70) and the IAEA dosimetry laboratory. However, there are some undesirable characteristics of this dosimetry system. We have a study in progress at the IAEA to evaluate the alanine-ESR systems as an alternative to TLDs. There are several desirable qualities which make alanine an attractive dosemeter. Preliminary data suggest that the alanine-ESR dosimetry system has the potential to replace TLDs for intercomparison amongst SSDLs in the therapy-level dose regions. (Author)

  19. Image in nuclear dosimetry using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Guinsburg, G.; Matsuoka, M.; Watanabe, S.

    1987-01-01

    A low cost methodology to produce images of internal sick organs by radioisotopic intake, is presented. Dosimetries of thermoluminescent material and Teflon (ratio:50%) in bidimensional matrix shape are used with a Pb collimator. This collimator-bidimensional matrix system was tested ''in vivo'' and in thyroid phantoms using 99m Tc. A comparative evaluation between this method and the scintigraphy one is presented. (M.A.C.) [pt

  20. The physics of small megavoltage photon beam dosimetry.

    Science.gov (United States)

    Andreo, Pedro

    2018-02-01

    The increased interest during recent years in the use of small megavoltage photon beams in advanced radiotherapy techniques has led to the development of dosimetry recommendations by different national and international organizations. Their requirement of data suitable for the different clinical options available, regarding treatment units and dosimetry equipment, has generated a considerable amount of research by the scientific community during the last decade. The multiple publications in the field have led not only to the availability of new invaluable data, but have also contributed substantially to an improved understanding of the physics of their dosimetry. This work provides an overview of the most important aspects that govern the physics of small megavoltage photon beam dosimetry. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Passive Dosimetry Of Nuclear Medicine Service Staff, Ibn Sina Hospital

    International Nuclear Information System (INIS)

    Sebihi, R.; Talsmat, K.; Cherkaoui, R.; Ben Rais, N.

    2010-01-01

    Full text: Since the implementation of Law No. 00571 of 21 Chaabane 1391 on protection against ionizing radiation and its decrees 2: 2-97-30 and 2-97-132 28 October 1997, surveillance of workers has the subject of major regulatory developments in Morocco, including individual registration delayed for dosimetry. As part of optimizing the protection of medical personnel, a dosimetric study was performed for the first time at the national level, the Nuclear Medicine Service of the Ibn Sina hospital in collaboration with the National Center for Energy Sciences and Nuclear Techniques (CNESTEN). Dosimetric monitoring was conducted for 2 weeks with the use of passive thermoluminescent dosimeters, (GR200A), covering all categories of staff. The administration of samarium (β emitter with energy substantially higher than the energies encountered in conventional nuclear medicine) has been studied, given his first service. Other cases of people concerned our study: a pregnant woman doctor, whose exposure of the unborn child must be reduced as much as possible, and a woman from a private company, working without dosimeter, handles maintenance of premises. To control the conditions imposed on all activities requiring exposure to ionizing radiation, we evaluated the dose at the extremities of operators with the use of ring dosimeters (GR200A) and the dose on the ambient environment of staff (dosimeters ALNOR). This experiment has shown exposure levels below legal limits, without been negligible for certain post. The evaluation results equivalent doses manipulators justify the wearing of dosimeter rings as a complementary dosimeter in Nuclear Medicine service and a way of controlling the normal working conditions. Finally Monitoring ambient dosimetry showed that the environment is low radiation doses. Lessons learned from this study, for the protection of personnel are as follows: from the simple awareness of staff and means of optimizing radiation can maintain a dosimetry annual

  2. Characterization of the evolution of the pharmaceutical regulatory environment.

    Science.gov (United States)

    Shafiei, Nader; Ford, James L; Morecroft, Charles W; Lisboa, Paulo J; Taylor, Mark J

    2013-01-01

    This paper is part of a research study that is intended to identify pharmaceutical quality risks induced by the ongoing transformation in the industry. This study establishes the current regulatory context by characterizing the development of the pharmaceutical regulatory environment. The regulatory environment is one of the most important external factors that affects a company's organization, processes, and technological strategy. This is especially the case with the pharmaceutical industry, where its products affect the quality of life of the consumers. The quantitative analysis of regulatory events since 1813 and review of the associated literature resulted in identification of six factors influencing the regulatory environment, namely public health protection, public health promotion, crisis management, harmonization, innovation, and modernization. From 1813 to the 1970s the focus of regulators was centered on crisis management and public health protection-a basic mission that has remained consistent over the years. Since the 1980s a gradual move in the regulatory environment towards a greater focus on public health promotion, international harmonization, innovation, and agency modernization may be seen. The pharmaceutical industry is currently going through changes that affect the way it performs its research, manufacturing, and regulatory activities. The impact of these changes on the approaches to quality risk management requires more understanding. The authors are engaged in research to identify elements of the changes that influence pharmaceutical quality. As quality requirements are an integral part of the pharmaceutical regulations, a comprehensive understanding of these regulations is seen as the first step. The results of this study show that (i) public health protection, public health promotion, crisis management, harmonization, innovation, and modernization are factors that affect regulations in the pharmaceutical industry; (ii) the regulators' main

  3. Status of neutron cross sections for reactor dosimetry

    International Nuclear Information System (INIS)

    Vlasov, M.F.; Fabry, A.; McElroy, W.N.

    1977-03-01

    The status of current international efforts to develop standardized sets of evaluated energy-dependent (differential) neutron cross sections for reactor dosimetry is reviewed. The status and availability of differential data are considered, some recent results of the data testing of the ENDF/B-IV dosimetry file using 252 Cf and 235 U benchmark reference neutron fields are presented, and a brief review is given of the current efforts to characterize and identify dosimetry benchmark radiation fields

  4. Independence and the Irish Environmental Protection Agency: A Comparative Assessment

    OpenAIRE

    Shipan, Charles

    2006-01-01

    The Environmental Protection Agency is one of the most prominent regulatory agencies in Ireland. Created in 1992, one of the hallmarks of this agency is its independence from other parts of government. Yet little is known about the actual extent of its independence. Independence and the Irish Environmental Protection Agency: A Comparative Assessment addresses several key questions about the agency's independence. Why was independence such a primary justification for the creation of this a...

  5. Reassessment of the atomic bomb radiation dosimetry for Hiroshima and Nagasaki. Dosimetry system 2002. DS02. Volume 1

    International Nuclear Information System (INIS)

    Young, Robert W.; Kerr, George D.

    2005-01-01

    The extensive efforts to review the dosimetry of the atomic-bomb survivors and formulate the new dosimetry system DS02 have been greatly welcomed by the Radiation Effects Research Foundation (RERF). This accomplishment is a fine tribute to the importance of the epidemiological studies being conducted at RERF. No other study is so informative of the effects of radiation on human health. The gracious participation in the RERF program by the atomic-bomb survivors allows us to contribute to the well being of these individuals, and the high quality of the data obtained allows the RERF results to feature so prominently in the formulation of international guidelines for radiation protection. Such a great effort to improve and substantiate the dosimetry would not otherwise have been justified. RERF greatly appreciates the independent work of the U.S. and Japanese Working Groups on the atomic-bomb dosimetry and the review by the Joint Senior Review Group of this overall effort. We are assured that unbiased development of the new dosimetry system will reflect well in its application in the RERF epidemiology study. The documentation included in this report will serve as reference for the many deliberations concluded. The title publications are divided into 2 volumes. This is the first volume. The 8 of the reports in each chapter are indexed individually. (J.P.N.)

  6. Reassessment of the atomic bomb radiation dosimetry for Hiroshima and Nagasaki. Dosimetry system 2002. DS02. Volume 2

    International Nuclear Information System (INIS)

    Young, Robert W.; Kerr, George D.

    2005-01-01

    The extensive efforts to review the dosimetry of the atomic-bomb survivors and formulate the new dosimetry system DS02 have been greatly welcomed by the Radiation Effects Research Foundation (RERF). This accomplishment is a fine tribute to the importance of the epidemiological studies being conducted at RERF. No other study is so informative of the effects of radiation on human health. The gracious participation in the RERF program by the atomic-bomb survivors allows us to contribute to the well being of these individuals, and the high quality of the data obtained allows the RERF results to feature so prominently in the formulation of international guidelines for radiation protection. Such a great effort to improve and substantiate the dosimetry would not otherwise have been justified. RERF greatly appreciates the independent work of the U.S. and Japanese Working Groups on the atomic-bomb dosimetry and the review by the Joint Senior Review Group of this overall effort. We are assured that unbiased development of the new dosimetry system will reflect well in its application in the RERF epidemiology study. The documentation included in this report will serve as reference for the many deliberations concluded. The title publications are divided into 2 volumes. This is the second volume. The 29 of the reports in each chapter are indexed individually. (J.P.N.)

  7. Advances in biomedical dosimetry

    International Nuclear Information System (INIS)

    1981-01-01

    Full text: Radiation dosimetry, the accurate determination of the absorbed dose within an irradiated body or a piece of material, is a prerequisite for all applications of ionizing radiation. This has been known since the very first radiation applications in medicine and biology, and increasing efforts are being made by radiation researchers to develop more reliable, effective and safe instruments, and to further improve dosimetric accuracy for all types of radiation used. Development of new techniques and instrumentation was particularly fast in the field of both medical diagnostic and therapeutic radiology. Thus, in Paris in October the IAEA held the latest symposium in its continuing series on dosimetry in medicine and biology. The last one was held in Vienna in 1975. High-quality dosimetry is obviously of great importance for human health, whether the objectives lie in the prevention and control of risks associated with the nuclear industry, in medical uses of radioactive substances or X-ray beams for diagnostic purposes, or in the application of photon, electron or neutron beams in radiotherapy. The symposium dealt with the following subjects: General aspects of dosimetry; Special physical and biomedical aspects; Determination of absorbed dose; Standardization and calibration of dosimetric systems; and Development of dosimetric systems. The forty or so papers presented and the discussions that followed them brought out a certain number of dominant themes, among which three deserve particular mention. - The recent generalization of the International System of Units having prompted a fundamental reassessment of the dosimetric quantities to be considered in calibrating measuring instruments, various proposals were advanced by the representatives of national metrology laboratories to replace the quantity 'exposure' (SI unit = coulomb/kg) by 'Kerma' or 'absorbed dose' (unit joule/kg, the special name of which is 'gray'), this latter being closer to the practical

  8. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Otto, T.

    1997-01-01

    In 1996, the Dosimetry and Calibration Section was, as in previous years, mainly engaged in routine tasks: the distribution of over 6000 dosimeters (with a total of more than 10,000 films) every two months and the calibration of about 900 fixed and mobile instruments used in the radiation survey sections of RP group. These tasks were, thanks to an experienced team, well mastered. Special efforts had to be made in a number of areas to modernize the service or to keep it in line with new prescriptions. The Individual Dosimetry Service had to assure that CERN's contracting firms comply with the prescriptions in the Radiation Safety Manual (1996) that had been inspired by the Swiss Ordinance of 1994: Companies must file for authorizations with the Swiss Federal Office for Public Health requiring that in every company an 'Expert in Radiation Protection' be nominated and subsequently trained. CERN's Individual Dosimetry Service is accredited by the Swiss Federal Authorities and works closely together with other, similar services on a rigorous quality assurance programme. Within this framework, CERN was mandated to organize this year the annual Swiss 'Intercomparison of Dosimeters'. All ten accredited dosimetry services - among others those of the Paul Scherrer Institute (PSI) in Villigen and of the four Swiss nuclear power stations - sent dosimeters to CERN, where they were irradiated in CERN's calibration facility with precise photon doses. After return to their origin they were processed and evaluated. The results were communicated to CERN and were compared with the originally given doses. A report on the results was subsequently prepared and submitted to the Swiss 'Group of Experts on Personal Dosimetry'. Reference monitors for photon and neutron radiation were brought to standard laboratories to assure the traceability of CERN's calibration service to the fundamental quantities. For photon radiation, a set of ionization chambers was calibrated in the reference field

  9. 77 FR 40817 - Low-Level Radioactive Waste Regulatory Management Issues

    Science.gov (United States)

    2012-07-11

    ...-2011-0012] RIN-3150-AI92 Low-Level Radioactive Waste Regulatory Management Issues AGENCY: Nuclear... regulatory time of compliance for a low-level radioactive waste disposal facility, allowing licensees the... system, and revising the NRC's licensing requirements for land disposal of radioactive waste. DATES: The...

  10. Software for evaluation of EPR-dosimetry performance

    International Nuclear Information System (INIS)

    Shishkina, E.A.; Timofeev, Yu.S.; Ivanov, D.V.

    2014-01-01

    Electron paramagnetic resonance (EPR) with tooth enamel is a method extensively used for retrospective external dosimetry. Different research groups apply different equipment, sample preparation procedures and spectrum processing algorithms for EPR dosimetry. A uniform algorithm for description and comparison of performances was designed and implemented in a new computer code. The aim of the paper is to introduce the new software 'EPR-dosimetry performance'. The computer code is a user-friendly tool for providing a full description of method-specific capabilities of EPR tooth dosimetry, from metrological characteristics to practical limitations in applications. The software designed for scientists and engineers has several applications, including support of method calibration by evaluation of calibration parameters, evaluation of critical value and detection limit for registration of radiation-induced signal amplitude, estimation of critical value and detection limit for dose evaluation, estimation of minimal detectable value for anthropogenic dose assessment and description of method uncertainty. (authors)

  11. Dosimetry-based treatment planning for molecular radiotherapy: a summary of the 2017 report from the Internal Dosimetry Task Force

    Directory of Open Access Journals (Sweden)

    Caroline Stokke

    2017-11-01

    Full Text Available Abstract Background The European directive on basic safety standards (Council directive 2013/59 Euratom mandates dosimetry-based treatment planning for radiopharmaceutical therapies. The directive comes into operation February 2018, and the aim of a report produced by the Internal Dosimetry Task Force of the European Association of Nuclear Medicine is to address this aspect of the directive. A summary of the report is presented. Results A brief review of five of the most common therapy procedures is included in the current text, focused on the potential to perform patient-specific dosimetry. In the full report, 11 different therapeutic procedures are included, allowing additional considerations of effectiveness, references to specific literature on quantitative imaging and dosimetry, and existing evidence for absorbed dose-effect correlations for each treatment. Individualized treatment planning with tracer diagnostics and verification of the absorbed doses delivered following therapy is found to be scientifically feasible for almost all procedures investigated, using quantitative imaging and/or external monitoring. Translation of this directive into clinical practice will have significant implications for resource requirements. Conclusions Molecular radiotherapy is undergoing a significant expansion, and the groundwork for dosimetry-based treatment planning is already in place. The mandated individualization is likely to improve the effectiveness of the treatments, although must be adequately resourced.

  12. Role of secondary standard dosimetry laboratory in radiation protection program

    International Nuclear Information System (INIS)

    Rahman, Sohaila; Ali, Noriah Mohd.

    2008-01-01

    Full text: The radiation dosimetry program is an important element of operational radiation protection. Dosimetry data enable workers and radiation protection professionals to evaluate and control work practices to eliminate unnecessary exposure to ionizing radiation. The usefulness of the data produced however depends on its quality and traceability. The emphasis of the global dosimetry program is focused through the IAEA/WHO network of secondary standard dosimetry laboratories (SSDLs), which aims for the determination of SI quantities through proper traceable calibration of radiation protection equipment. The responsibility of SSDL-NUCLEAR MALAYSIA to guarantee a reliable dosimetry service, which is traceable to international standards, is elucidated. It acts as the basis for harmonized occupational radiation monitoring in Malaysia.

  13. EPR Dosimetry - Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Regulla, D.F. [GSF - National Research Centre for Environment and Health, Institute of Radiation Protection, 85764 Neuherberg (Germany)

    1999-07-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  14. Fundamentals of Dosimetry. Chapter 3

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, E. M. [Universidade de São Paulo, São Paulo (Brazil)

    2014-09-15

    Determination of the energy imparted to matter by radiation is the subject of dosimetry. The energy deposited as radiation interacts with atoms of the material, as seen in the previous chapter. The imparted energy is responsible for the effects that radiation causes in matter, for instance, a rise in temperature, or chemical or physical changes in the material properties. Several of the changes produced in matter by radiation are proportional to the absorbed dose, giving rise to the possibility of using the material as the sensitive part of a dosimeter. Also, the biological effects of radiation depend on the absorbed dose. A set of quantities related to the radiation field is also defined within the scope of dosimetry. It will be shown in this chapter that, under special conditions, there are simple relations between dosimetric and field description quantities. Thus, the framework of dosimetry is the set of physical and operational quantities that are studied in this chapter.

  15. EPR Dosimetry - Present and Future

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  16. I-124 Imaging and Dosimetry

    Directory of Open Access Journals (Sweden)

    Russ Kuker

    2017-02-01

    Full Text Available Although radioactive iodine imaging and therapy are one of the earliest applications of theranostics, there still remain a number of unresolved clinical questions as to the optimization of diagnostic techniques and dosimetry protocols. I-124 as a positron emission tomography (PET radiotracer has the potential to improve the current clinical practice in the diagnosis and treatment of differentiated thyroid cancer. The higher sensitivity and spatial resolution of PET/computed tomography (CT compared to standard gamma scintigraphy can aid in the detection of recurrent or metastatic disease and provide more accurate measurements of metabolic tumor volumes. However the complex decay schema of I-124 poses challenges to quantitative PET imaging. More prospective studies are needed to define optimal dosimetry protocols and to improve patient-specific treatment planning strategies, taking into account not only the absorbed dose to tumors but also methods to avoid toxicity to normal organs. A historical perspective of I-124 imaging and dosimetry as well as future concepts are discussed.

  17. Use of the GATE Monte Carlo package for dosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Visvikis, D. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France)]. E-mail: Visvikis.Dimitris@univ-brest.fr; Bardies, M. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Chiavassa, S. [INSERM U601, CHU Nantes, F 44093 Nantes (France); Danford, C. [Department of Medical Physics, MSKCC, New York (United States); Kirov, A. [Department of Medical Physics, MSKCC, New York (United States); Lamare, F. [INSERM U650, LaTIM, University Hospital Medical School, F 29609 Brest (France); Maigne, L. [Departement de Curietherapie-Radiotherapie, Centre Jean Perrin, F 63000 Clemont-Ferrand (France); Staelens, S. [UGent-ELIS, St-Pietersnieuwstraat, 41, B 9000 Gent (Belgium); Taschereau, R. [CRUMP Institute for Molecular Imaging, UCLA, Los Angeles (United States)

    2006-12-20

    One of the roles for Monte Carlo (MC) simulation studies is in the area of dosimetry. A number of different codes dedicated to dosimetry applications are available and widely used today, such as MCNP, EGSnrc and PTRAN. However, such codes do not easily facilitate the description of complicated 3D sources or emission tomography systems and associated data flow, which may be useful in different dosimetry application domains. Such problems can be overcome by the use of specific MC codes such as GATE (GEANT4 Application to Tomographic Emission), which is based on Geant4 libraries, providing a scripting interface with a number of advantages for the simulation of SPECT and PET systems. Despite this potential, its major disadvantage is in terms of efficiency involving long execution times for applications such as dosimetry. The strong points and disadvantages of GATE in comparison to other dosimetry specific codes are discussed and illustrated in terms of accuracy, efficiency and flexibility. A number of features, such as the use of voxelised and moving sources, as well as developments such as advanced visualization tools and the development of dose estimation maps allowing GATE to be used for dosimetry applications are presented. In addition, different examples from dosimetry applications with GATE are given. Finally, future directions with respect to the use of GATE for dosimetry applications are outlined.

  18. Database to manage personal dosimetry Hospital Universitario de La Ribera

    International Nuclear Information System (INIS)

    Melchor, M.; Martinez, D.; Asensio, M.; Candela, F.; Camara, A.

    2011-01-01

    For the management of professionally exposed personnel dosimetry, da La are required for the use and return of dosimeters. in the Department of Radio Physics and Radiation Protection have designed and implemented a database management staff dosimetry Hospital and Area Health Centers. The specific objectives were easily import data from the National Center dosimetric dosimetry, consulting records in a simple dosimetry, dosimeters allow rotary handle, and also get reports from different periods of time to know the return data for users, services, etc.

  19. Activity Of EURADOS In Environmental Solid State Dosimetry

    International Nuclear Information System (INIS)

    Ranogajec-Komor, M.; Duch, M. A.; Haninger, T.

    2015-01-01

    Working Group 3 (WG3) of the European Radiation Dosimetry Group (EURADOS) carries out research projects and coordinated activities to advance the scientific understanding of environmental dosimetry and especially to promote the technical development of new methods in environmental monitoring. In this field of dosimetry, the measurement of small additional doses caused by artificial radiation on top of the natural environmental radiation is a challenge. Further, WG3 stimulates the organisation of intercomparison programmes and the definition of standards and recommendations in the field of environmental radiation monitoring (ERM). WG3 has played a significant role in the harmonisation of early warning dosimetry network stations in Europe and has organised 6 EURADOS intercomparison exercises; in which 42 institutions from 19 countries have participated. Today, about 5000 stations provide real-time dose rate data to a database run by the European Commission. Within WG3 a subgroup (S1) on spectrometry system was formed in 2013. Since then, WG3 has been involved in the field of spectrometry systems used both for dosimetric and spectrometric monitoring in the environment. A remarkable result of the WG3 - S1 is that many members contributed to the new European Joint Research Project 'Metrology for radiological early warning networks in Europe' which started in 2014. A second subgroup WG3 - S2 on passive dosimetry in ERM was inaugurated in 2014. To gain an overview of the passive dosimetry practice in ERM, WG3 - S2 decided to collect information by means of a questionnaire which has been send to European dosimetry services. One of the results was the identification of some open questions, problems in ERM (for example terminology, protocol of routine dosimetry, uncertainty assessment) which require clarification for harmonisation of ERM using passive dosimeters. Another result was that there exists a need for intercomparisons. The first intercomparison for passive

  20. Medical reference dosimetry using EPR measurements of alanine

    DEFF Research Database (Denmark)

    Helt-Hansen, Jakob; Rosendal, F.; Kofoed, I.M.

    2009-01-01

    Background. Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low...... methods the proposed algorithm can be applied without normalisation of phase shifts caused by changes in the g-value of the cavity. The study shows that alanine dosimetry is a suitable candidate for medical reference dosimetry especially for quality control applications.......Background. Electron spin resonance (EPR) is used to determine the absorbed dose of alanine dosimeters exposed to clinical photon beams in a solid-water phantom. Alanine is potentially suitable for medical reference dosimetry, because of its near water equivalence over a wide energy spectrum, low...

  1. 75 FR 61485 - Regulatory Training Session With Air Carriers, EPA Regional Partners and Other Interested Parties...

    Science.gov (United States)

    2010-10-05

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9210-6] Regulatory Training Session With Air Carriers, EPA... Agency (EPA) will hold a two-day training session on the regulatory requirements of the Aircraft Drinking... session will be provided in early 2011. ADDRESSES: The training will be held at the Rosslyn Holiday Inn at...

  2. 78 FR 24754 - Guidance for Industry on Regulatory Classification of Pharmaceutical Co-Crystals; Availability

    Science.gov (United States)

    2013-04-26

    ...] Guidance for Industry on Regulatory Classification of Pharmaceutical Co-Crystals; Availability AGENCY: Food... announcing the availability of a guidance for industry entitled ``Regulatory Classification of Pharmaceutical... on the appropriate regulatory classification of pharmaceutical co-crystal solid-state forms. This...

  3. The IAEA/WHO thermoluminescent dosimetry intercomparison used for the improvement of clinical dosimetry

    International Nuclear Information System (INIS)

    Racoveanu, N.T.

    1981-01-01

    Results of thermoluminescent dosimetry collected over 5 years in the Eastern Mediterranean region of WHO were analyzed in an attempt to improve clinical dosimetry. Data for 16 radiotherapy departments showed considerable inconsistencies. It was found that the clinical dosemeters used by 3 of the departments were not working properly. The remainder of the departments had one or more dosemeters in perfect working order but the procedure for measuring machine output was inadequate or the correction factors (pressure, temperature) were wrongly applied due to lack of reliable instruments for such measurements. Problems encountered in the sending and returning of TLD dosemeters for assessment are discussed

  4. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2010-04-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision

  5. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2011-04-04

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision

  6. Environmental Regulatory Update Table, May/June 1992

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Lewis, E.B.; Salk, M.S.

    1992-07-01

    This report contains a bi-monthly update of environmental regulatory activity that is of interest to the Department of Energy. It is provided to DOE operations and contractor staff to assist and support environmental management programs by tracking regulatory developments. Any proposed regulation that raises significant issues for any DOE operation should be reported to the Office of Environmental Guidance (EH-23) as soon as possible so that the Department can make its concerns known to the appropriate regulatory agency. Items of particular interest to EH-23 are indicated by a shading of the RU{number sign}.

  7. Environmental Regulatory Update Table, May/June 1992

    Energy Technology Data Exchange (ETDEWEB)

    Houlberg, L.M.; Hawkins, G.T.; Lewis, E.B.; Salk, M.S.

    1992-07-01

    This report contains a bi-monthly update of environmental regulatory activity that is of interest to the Department of Energy. It is provided to DOE operations and contractor staff to assist and support environmental management programs by tracking regulatory developments. Any proposed regulation that raises significant issues for any DOE operation should be reported to the Office of Environmental Guidance (EH-23) as soon as possible so that the Department can make its concerns known to the appropriate regulatory agency. Items of particular interest to EH-23 are indicated by a shading of the RU{number_sign}.

  8. Computerized dosimetry management systems within EDF

    International Nuclear Information System (INIS)

    Daubert, G.

    1996-01-01

    EDF, using the ALARA approach, has embarked an ambitious project of optimising the doses received in its power plants. In directing its choice of actions and the effectiveness of such actions, the French operator is using a computerized personal and collective dosimetry management system. This system provides for ongoing monitoring of dosimetry at personal, site and unit level or indeed for the entire population of EDF nuclear power plants. (author)

  9. Implications of ISO 9000 for personnel dosimetry

    International Nuclear Information System (INIS)

    Yoder, R.C.

    1995-01-01

    Landauer, Inc. has gained approval to provide personnel dosimetry services in several countries. Each experiene reflects the different concerns adopted by national approval agencies. None have adopted ISO 9000 registration as evidence of a suitable quality system of management. Instead, each organization has prepared its own set of requirements with no provisions for recognizing the results of performance tests or audits conducted by other approval organizations. As ISO 9000 has become a communication symbol for commercial organizations dealing with each other, it has not been similarly viewed by radiation regulation bodies. A key reason arises from a tradition to regulate bodies. A key reason arises from a tradition to regulate, not promote, international trade, not encourage innovation, nor foster economic competition. A second reason is the inability to separate the technical requirements from quality assurance. ISO 9000 may become useful once the national technical organizations learn to trust those of other countries

  10. Compilation of documented computer codes applicable to environmental assessment of radioactivity releases

    International Nuclear Information System (INIS)

    Hoffman, F.O.; Miller, C.W.; Shaeffer, D.L.; Garten, C.T. Jr.; Shor, R.W.; Ensminger, J.T.

    1977-04-01

    The objective of this paper is to present a compilation of computer codes for the assessment of accidental or routine releases of radioactivity to the environment from nuclear power facilities. The capabilities of 83 computer codes in the areas of environmental transport and radiation dosimetry are summarized in tabular form. This preliminary analysis clearly indicates that the initial efforts in assessment methodology development have concentrated on atmospheric dispersion, external dosimetry, and internal dosimetry via inhalation. The incorporation of terrestrial and aquatic food chain pathways has been a more recent development and reflects the current requirements of environmental legislation and the needs of regulatory agencies. The characteristics of the conceptual models employed by these codes are reviewed. The appendixes include abstracts of the codes and indexes by author, key words, publication description, and title

  11. In vivo dosimetry in radiation therapy in Sweden

    International Nuclear Information System (INIS)

    Eriksson, Jacob; Blomquist, Michael

    2010-07-01

    A prerequisite for achieving high radiation safety for patients receiving external beam radiation therapy is that the hospitals have a quality assurance program. The program should include include monitoring of the radiation dose given to the patient. Control measurements are performed both at the system level and at the individual level. Control measurement is normally performed using in vivo dosimetry, e.g. a method to measure the radiation dose at the individual level during the actual radiation treatment time. In vivo dosimetry has proven to be an important tool to detect and prevent serious errors in patient treatment. The purpose of this research project was to identify the extent to which vivo dosimetry is used and the methods available for this at Swedish radiation therapy clinics. The authority also wanted to get an overall picture of how hospitals manage results of in vivo dosimetry, and how clinics control radiation dose when using modern treatment techniques. The report reflects the situation in Swedish radiotherapy clinics 2007. The report shows that all hospitals use some form of in vivo dosimetry. The instruments used are mainly diodes and termoluminiscence dosimeters

  12. Trends of personal dosimetry at atomic power plants

    International Nuclear Information System (INIS)

    Yamamura, Seini

    1998-01-01

    The individual dosimetry at the atomic power station is sorted for monthly dosimetry, daily dosimetry and special job dosimetry in high dose circumstance. Film badge (passive dosimeter) can measure gamma dose, beta dose and neutron dose respectively lower than about 0.1 mSv. While workers are in the radiation controlled area, they have to wear the dosimeters and the individual dose is accumulated for every one month. Recently the Silicon semiconductors detecting beta ray and neutron have been developed. With microcircuit technology and these new sensors, new multiple function dosimeter of the card size had been put to practical use. The result of dose measurement obtained by the electronic dosimeter is consistent well with the measurement of usual film badge and new dosimeter can determine the dose as low as 0.01 mSv. The result is stored in the non-volatile memory in the electronic personal dosimeter and held for more than one year without the power supply. The function to read data directly from the memory improves the reliability of the data protection. The realization of the unified radiation control system that uses the electronic personal dosimeter for monthly dosimetry is expected. (J.P.N.)

  13. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    CERN Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page http://cern.ch/rp-dosimetry. The Dosimetry Service is open every morning from 8.30 - 12.00, and closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats.

  14. Performance-Based (Risk-Informed) Regulation: A Regulatory Perspective

    International Nuclear Information System (INIS)

    Kadambi, N. Prasad

    2005-01-01

    Performance-based regulation (PBR) has been mandated at the national level in the United States and at the agency level, where appropriate, at the U.S. Nuclear Regulatory Commission (USNRC). Guidance has been developed that implements the USNRC's definitions of PBR and other such conceptual regulatory improvements. This paper describes why PBR is important, what constitutes PBR in the context of direction provided at the USNRC, and how PBR can be implemented using a five-step process. The process steps articulate questions to be posed by the analyst regarding various aspects of a regulatory issue so that a suitably performance-based resolution can be developed. A regulatory alternative thus developed can be included among other options to be considered as part of the regulatory decision-making process

  15. Assessment by peer review of the effectiveness of a regulatory programme for radiation safety. Interim report for comment

    International Nuclear Information System (INIS)

    2002-06-01

    This document covers assessment of those aspects of a radiation protection and safety infrastructure that are implemented by the Regulatory Authority for radiation sources and practices using such sources and necessarily includes those ancillary technical services, such as dosimetry services, which directly affect the ability of the Regulatory Authority to discharge its responsibilities. The focus of the guidance in this TECDOC is on assessment of a regulatory programme intended to implement the BSS. The BSS address transportation and waste safety mainly by reference to other IAEA documents. When conducting an assessment, the Review Team members should be aware of the latest IAEA documents (or similar national documents) concerning transportation and waste safety and, if appropriate, nuclear safety, and take them into account to the extent applicable when assessing the effectiveness of the regulatory programme governing radiation protection and safety of radiation source practices in a particular State

  16. Assessment by peer review of the effectiveness of a regulatory programme for radiation safety. Interim report for comment

    International Nuclear Information System (INIS)

    2001-05-01

    This document covers assessment of those aspects of a radiation protection and safety infrastructure that are implemented by the Regulatory Authority for radiation sources and practices using such sources and necessarily includes those ancillary technical services, such as dosimetry services, which directly affect the ability of the Regulatory Authority to discharge its responsibilities. The focus of the guidance in this TECDOC is on assessment of a regulatory programme intended to implement the BSS. The BSS address transportation and waste safety mainly by reference to other IAEA documents. When conducting an assessment, the Review Team members should be aware of the latest IAEA documents (or similar national documents) concerning transportation and waste safety and, if appropriate, nuclear safety, and take them into account to the extent applicable when assessing the effectiveness of the regulatory programme governing radiation protection and safety of radiation source practices in a particular State

  17. IAEA Mission Sees Significant Progress in Georgia’s Regulatory Framework, Challenges Ahead

    International Nuclear Information System (INIS)

    2018-01-01

    An International Atomic Energy Agency (IAEA) team of experts said Georgia has made significant progress in strengthening its regulatory framework for nuclear and radiation safety. The team also pointed to challenges ahead as Georgia seeks to achieve further progress. The Integrated Regulatory Review Service (IRRS) team concluded a 10-day mission on 28 February to assess the regulatory safety framework in Georgia. The mission was conducted at the request of the Government and hosted by the Agency of Nuclear and Radiation Safety (ANRS), which is responsible for regulatory oversight in the country. IRRS missions are designed to strengthen the effectiveness of the national safety regulatory infrastructure, while recognizing the responsibility of each State to ensure nuclear and radiation safety. Georgia uses radioactive sources in medicine and industry and operates radioactive waste management facilities. It has decommissioned its only research reactor and has no nuclear power plants. In recent years, the Government and ANRS, with assistance from the IAEA, introduced new safety regulations and increased the number of regulatory inspections.

  18. Regulatory requirements of the integrated technology demonstration program, Savannah River Site (U)

    International Nuclear Information System (INIS)

    Bergren, C.L.

    1992-01-01

    The integrated demonstration program at the Savannah River Site (SRS) involves demonstration, testing and evaluation of new characterization, monitoring, drilling and remediation technologies for soils and groundwater impacted by organic solvent contamination. The regulatory success of the demonstration program has developed as a result of open communications between the regulators and the technical teams involved. This open dialogue is an attempt to allow timely completion of applied environmental restoration demonstrations while meeting all applicable regulatory requirements. Simultaneous processing of multiple regulatory documents (satisfying RCRA, CERCLA, NEPA and various state regulations) has streamlined the overall permitting process. Public involvement is achieved as various regulatory documents are advertised for public comment consistent with the site's community relations plan. The SRS integrated demonstration has been permitted and endorsed by regulatory agencies, including the Environmental Protection Agency (EPA) and the South Carolina Department of Health and Environmental Control. EPA headquarters and regional offices are involved in DOE's integrated Demonstration Program. This relationship allows for rapid regulatory acceptance while reducing federal funding and time requirements. (author)

  19. European protocol for neutron dosimetry for external beam therapy

    International Nuclear Information System (INIS)

    Broerse, J.J.; Mijnheer, B.J.; Williams, J.R.

    1981-01-01

    The paper attempts to serve the needs of European centres participating in the High LET Therapy Project Group set up under the sponsorship of The European Organization for Research on Treatment of Cancer, to promote cooperation between physicists involved in fast neutron therapy and establish a common basis for neutron dosimetry. Differences in dosimetry procedures between European and American Groups are indicated if relevant. The subject is dealt with under the following main headings: principles of dosimetry of neutron fields, dosimetric methods, physical parameters, determination of absorbed dose at a reference point, determination of absorbed dose at any point, check of absorbed dose given to a patient, dosimetry intercomparisons between institutes. There is an ample bibliography. (U.K.)

  20. Regulatory approaches to hydrocarbon contamination from underground storage tanks

    International Nuclear Information System (INIS)

    Daugherty, S.J.

    1991-01-01

    Action or lack of action by the appropriate regulatory agency is often the most important factor in determining remedial action or closure requirements for hydrocarbon contaminated sites. This paper reports that the diversity of regulatory criteria is well known statewide and well documented nationally. In California, the diversity of approaches is due to: that very lack of a clear understanding of the true impact of hydrocarbon contamination: lack of state or federal standards for soil cleanup, and state water quality objectives that are not always achievable; vagueness in the underground storage tank law; and the number and diversity of agencies enforcing the underground storage tank regulations

  1. Corporate Social Responsibility and Labour Agency

    DEFF Research Database (Denmark)

    Lund-Thomsen, Peter; Coe, Neil M.

    2015-01-01

    to which the measures advocated in a new, emerging policy paradigm on CSR in GPNs enabled labour agency at Nike’s main football supplier factory in Pakistan. We argue that while such CSR policies can create enhanced space for labour agency, that potential agency is also shaped (i) by wider economic forces......This article examines the circumstances under which corporate social responsibility (CSR) initiatives facilitate and/or constrain labour agency in global production networks (GPNs). Using a case study of Nike’s CSR approach in the football manufacturing industry of Pakistan, we explore the extent...... within the global economy and (ii) relationships with local/national actors and regulatory frameworks. Understanding the intersection of these dimensions becomes vital to interpreting the potential for, and activation of, labour agency within CSR-influenced GPNs....

  2. Neutron beam measurement dosimetry

    International Nuclear Information System (INIS)

    Amaro, C.R.

    1995-01-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR

  3. WIPP radiation dosimetry program

    International Nuclear Information System (INIS)

    Wu, C.F.

    1991-01-01

    Radiation dosimetry is the process by which various measurement results and procedures are applied to quantify the radiation exposure of an individual. Accurate and precise determination of radiation dose is a key factor to the success of a radiation protection program. The Waste Isolation Pilot Plant (WIPP), a Department of Energy (DOE) facility designed for permanent repository of transuranic wastes in a 2000-foot-thick salt bed 2150 feet underground, has established a dosimetry program developed to meet the requirements of DOE Order 5480.11, ''Radiation Protection for Occupational Workers''; ANSI/ASME NQA-1, ''Quality Assurance Program Requirements for Nuclear Facilities''; DOE Order 5484.1, ''Environmental Protection, Safety, and Health Protection Information Reporting Requirements''; and other applicable regulations

  4. Sharing regulatory data as tools for strengthening health systems in the Region of the Americas

    Directory of Open Access Journals (Sweden)

    Varley Dias Sousa

    Full Text Available ABSTRACT Regulatory transparency is an imperative characteristic of a reliable National Regulatory Authority. In the region of the Americas, the process of building an open government is still fragile and fragmented across various Health Regulatory Agencies (HRAs and Regional Reference Authorities (RRAs. This study assessed the transparency status of RRAs, focusing on various medicine life-cycle documents (the Medicine Dossier, Clinical Trial Report, and Inspection Report as tools for strengthening health systems. Based on a narrative (nonsystematic review of RRA regulatory transparency, transparency status was classified as one of two types: public disclosure of information (intra-agency data and data- and work-sharing (inter-agency data. The risks/benefits of public disclosure of medicine-related information were assessed, taking into account 1 the involvement and roles of multiple stakeholders (health care professionals, regulators, industry, community, and academics and 2 the protection of commercial and personal confidential data. Inter-agency data- and work-sharing was evaluated in the context of harmonization and cooperation projects that focus on regulatory convergence. Technical and practical steps for establishing an openness directive for the pharmaceutical regulatory environment are proposed to improve and strengthen health systems in the Americas. Addressing these challenges requires leadership from entities such as the Pan American Health Organization to steer and support collaborative regional alliances that advance the development and establishment of a trustworthy regulatory environment and a sustainable public health system in the Americas, using international successful initiatives as reference and taking into account the domestic characteristics and experiences of each individual country.

  5. Sharing regulatory data as tools for strengthening health systems in the Region of the Americas.

    Science.gov (United States)

    Sousa, Varley Dias; Ramalho, Pedro I; Silveira, Dâmaris

    2016-05-01

    Regulatory transparency is an imperative characteristic of a reliable National Regulatory Authority. In the region of the Americas, the process of building an open government is still fragile and fragmented across various Health Regulatory Agencies (HRAs) and Regional Reference Authorities (RRAs). This study assessed the transparency status of RRAs, focusing on various medicine life-cycle documents (the Medicine Dossier, Clinical Trial Report, and Inspection Report) as tools for strengthening health systems. Based on a narrative (nonsystematic) review of RRA regulatory transparency, transparency status was classified as one of two types: public disclosure of information (intra-agency data) and data- and work-sharing (inter-agency data). The risks/benefits of public disclosure of medicine-related information were assessed, taking into account 1) the involvement and roles of multiple stakeholders (health care professionals, regulators, industry, community, and academics) and 2) the protection of commercial and personal confidential data. Inter-agency data- and work-sharing was evaluated in the context of harmonization and cooperation projects that focus on regulatory convergence. Technical and practical steps for establishing an openness directive for the pharmaceutical regulatory environment are proposed to improve and strengthen health systems in the Americas. Addressing these challenges requires leadership from entities such as the Pan American Health Organization to steer and support collaborative regional alliances that advance the development and establishment of a trustworthy regulatory environment and a sustainable public health system in the Americas, using international successful initiatives as reference and taking into account the domestic characteristics and experiences of each individual country.

  6. 76 FR 9819 - Agency Information Collection Activities: Proposed Collection; Generic Clearance for the...

    Science.gov (United States)

    2011-02-22

    ...; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery; Correction AGENCY...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Regulatory Commission, Office of Personnel Management, Small Business Administration, and U.S. Agency for...

  7. Regulatory Control of Radiation Sources. Safety Guide

    International Nuclear Information System (INIS)

    2009-01-01

    This Safety Guide is intended to assist States in implementing the requirements established in Safety Standards Series No. GS-R-1, Legal and Governmental Infrastructure for Nuclear, Radiation, Radioactive Waste and Transport Safety, for a national regulatory infrastructure to regulate any practice involving radiation sources in medicine, industry, research, agriculture and education. The Safety Guide provides advice on the legislative basis for establishing regulatory bodies, including the effective independence of the regulatory body. It also provides guidance on implementing the functions and activities of regulatory bodies: the development of regulations and guides on radiation safety; implementation of a system for notification and authorization; carrying out regulatory inspections; taking necessary enforcement actions; and investigating accidents and circumstances potentially giving rise to accidents. The various aspects relating to the regulatory control of consumer products are explained, including justification, optimization of exposure, safety assessment and authorization. Guidance is also provided on the organization and staffing of regulatory bodies. Contents: 1. Introduction; 2. Legal framework for a regulatory infrastructure; 3. Principal functions and activities of the regulatory body; 4. Regulatory control of the supply of consumer products; 5. Functions of the regulatory body shared with other governmental agencies; 6. Organization and staffing of the regulatory body; 7. Documentation of the functions and activities of the regulatory body; 8. Support services; 9. Quality management for the regulatory system.

  8. Development and implementation of own software for dosimetry multichannel film

    International Nuclear Information System (INIS)

    Jimenez Feltstrom, D.; Reyes Garcia, R.; Luis Simon, F. J.; Carrasco Herrera, M.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2013-01-01

    The objective of this work is to develop its own software for multichannel film dosimetry Radiochromic EBT2. Compare the results obtained with its use in multichannel and single-channel dosimetry. Check that the multi-channel dosimetry eliminates much of the artifacts caused by dirt, fingerprints, scratches, etc. Radiochromic in film and scanner devices. (Author)

  9. Biological dosimetry in cases gives occupational high exposition to ionizing radiations

    International Nuclear Information System (INIS)

    Ramalho, Adriana T.; Costa, Maria Lucia P.; Oliveira, Monica S.; Silva, Francisco Cesar A.

    1998-01-01

    From 1983 the cytogenetics dosimetry method it has been used as routine in the IRD laboratory in the period 1983 at 1997 but a high exposition occupational case the physical dosimeters happened in Brazil they were investigated through the cytogenetics dosimetry technique. This technique is employ when the dosimetry personal marks a high dose to 100 mSv (0,1 Gy) that is the cut-off minimum detected in the dosimetry cytogenetics

  10. EPR dosimetry - present and future

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as co-ordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as biomarkers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (ASTM), and the International Organisation of Standards (ISO) as well as those of the International Commission on Radiation Units and Measurements (ICRU) considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (author)

  11. 78 FR 44403 - Unified Agenda of Federal Regulatory and Deregulatory Actions

    Science.gov (United States)

    2013-07-23

    ... agenda (the Agenda) in accordance with Public Law 96-354, ``The Regulatory Flexibility Act,'' and... goals; (2) support for the Strategic Plan organizational excellence objectives; (3) a governmental... Flexibility Act Section 610 of the Regulatory Flexibility Act (RFA) requires agencies to conduct a review...

  12. Regulatory perspective on remaining challenges for utilization of pharmacogenomics-guided drug developments.

    Science.gov (United States)

    Otsubo, Yasuto; Ishiguro, Akihiro; Uyama, Yoshiaki

    2013-01-01

    Pharmacogenomics-guided drug development has been implemented in practice in the last decade, resulting in increased labeling of drugs with pharmacogenomic information. However, there are still many challenges remaining in utilizing this process. Here, we describe such remaining challenges from the regulatory perspective, specifically focusing on sample collection, biomarker qualification, ethnic factors, codevelopment of companion diagnostics and means to provide drugs for off-target patients. To improve the situation, it is important to strengthen international harmonization and collaboration among academia, industries and regulatory agencies, followed by the establishment of an international guideline on this topic. Communication with a regulatory agency from an early stage of drug development is also a key to success.

  13. Phantom positioning variation in the Gamma Knife® Perfexion dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Nathalia Almeida; Potiens, Maria da Penha Albuquerque [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Saraiva, Crystian [Hospital do Coracao, Sao Paulo, SP (Brazil)

    2015-07-01

    The use of small volume ionization chamber has become required for the dosimetry of equipment that use small radiation fields. A pinpoint ionization chamber is ideal for the dosimetry of a Gamma Knife® Perfexion (GKP) unit. In this work, this chamber was inserted into the phantom, and measurements were performed with the phantom in different positions, in order to verify if the change in the phantom positioning affects the dosimetry of the GKP. Three different phantom positions were performed. The variation in the result is within the range allowed for the dosimetry of a GKP equipment. (author)

  14. Cytogenetic dosimetry in suspected cases of ionizing radiation occupational exposure

    International Nuclear Information System (INIS)

    Ramalho, Adriana T.; Costa, Maria Lucia P.; Oliveira, Monica S.; Silva, Francisco Cesar A. da

    2001-01-01

    Cytogenetic dosimetry is very useful in routine as well as in serious accident situations in which exposed individuals do not wear physical dosimeters. Since 1984, the technique of cytogenetic dosimetry has been used as a routine in our laboratory at IRD/CNEN to complement the data of physical dosimetry. In the period from 1984 to 2000, 138 cases of occupational overexposure of individual dosimeters were investigated by us. In total, only in 36 of the 138 cases investigated the overexposure was confirmed by cytogenetic dosimetry. The data indicates a total confirmation index of just 26% of the suspected cases.(author)

  15. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    International Nuclear Information System (INIS)

    Rathbone, Bruce A.

    2007-01-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL's Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL's Electronic Records and Information Capture Architecture (ERICA) database. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Revision Log: Rev. 0 (2/25/2005) Major revision and expansion. Rev. 0.1 (3/12/2007) Minor

  16. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2007-03-12

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL’s Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL’s Electronic Records & Information Capture Architecture (ERICA) database. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Revision Log: Rev. 0 (2/25/2005) Major revision and expansion. Rev. 0.1 (3/12/2007) Minor

  17. 75 FR 79449 - Introduction to The Regulatory Plan and the Unified Agenda of Federal Regulatory and Deregulatory...

    Science.gov (United States)

    2010-12-20

    ... Administration 79677 Office of Personnel Management 79679 Pension Benefit Guaranty Corporation 79681 Small... National Indian Gaming Commission 79706 Postal Regulatory Commission 79708 AGENCY AGENDAS Cabinet... Register twice each year since 1983 and has been available online since 1995. To further the objective of...

  18. 77 FR 70846 - Regulatory Guide 1.182, “Assessing and Managing Risk Before Maintenance Activities at Nuclear...

    Science.gov (United States)

    2012-11-27

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0285] Regulatory Guide 1.182, ``Assessing and Managing Risk Before Maintenance Activities at Nuclear Power Plants'' AGENCY: Nuclear Regulatory Commission... withdrawing Regulatory Guide (RG)1.182, Revision (Rev.) 0, ``Assessing and Managing Risk Before Maintenance...

  19. Assessment of regulatory effectiveness. Peer discussions on regulatory practices

    International Nuclear Information System (INIS)

    1999-09-01

    This report arises from the seventh series of peer discussions on regulatory practices entitled 'Assessment of Regulatory Effectiveness'. The term 'regulatory effectiveness' covers the quality of the work and level of performance of a regulatory body. In this sense, regulatory effectiveness applies to regulatory body activities aimed at preventing safety degradation and ensuring that an acceptable level of safety is being maintained by the regulated operating organizations. In addition, regulatory effectiveness encompasses the promotion of safety improvements, the timely and cost effective performance of regulatory functions in a manner which ensures the confidence of the operating organizations, the general public and the government, and striving for continuous improvements to performance. Senior regulators from 22 Member States participated in two peer group discussions during March and May 1999. The discussions were focused on the elements of an effective regulatory body, possible indicators of regulatory effectiveness and its assessment. This report presents the outcome of these meetings and recommendations of good practices identified by senior regulators, which do not necessarily reflect those of the governments of the nominating Member States, the organizations they belong to, or the International Atomic Energy Agency. In order to protect people and the environment from hazards associated with nuclear facilities, the main objective of a nuclear regulatory body is to ensure that a high level of safety in the nuclear activities under its jurisdiction is achieved, maintained and within the control of operating organizations. Even if it is possible to directly judge objective safety levels at nuclear facilities, such safety levels would not provide an exclusive indicator of regulatory effectiveness. The way the regulatory body ensures the safety of workers and the public and the way it discharges its responsibilities also determine its effectiveness. Hence the

  20. 77 FR 12896 - Self-Regulatory Organizations; Pacific Clearing Corporation; Order Cancelling Clearing Agency...

    Science.gov (United States)

    2012-03-02

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-66459; File No. 600-11] Self-Regulatory..., 2006), 72 FR 814 (Jan. 8, 2007). Section 19(a)(3) of the Act \\14\\ provides that in the event any self-regulatory organization is no longer in existence or has ceased to do business in the capacity specified in...