WorldWideScience

Sample records for regular screening colonoscopy

  1. Virtual colonoscopy - changes for screening examination?

    International Nuclear Information System (INIS)

    Rust, G.F.; Reiser, M.

    2002-01-01

    In principle, virtual colonoscopy is capable to be used as method for early detection of colorectal cancer (CRC), even if the accuracy of the method and radiation exposure are matters discussion in the radiological community. Virtual colonoscopy is able to detect any pathology which is relevant for early detection of CRC especially when using multislice CT, but also with single slice CT. The diagnosis of small lesions, less than 7 mm in diameter (polyps and flat lesions) is still problematic as it is in conventional colonoscopy. The exposure to x-rays in asymptomatic patients, without any increased risk of developing cancer is highly problematic and should be reduced to a minimum. Using special post processing filters on the volume dataset it can be shown that a tube current of 20 mAs is sufficient without any loss in accuracy. Measurements on the Alderson-phantom showed, that an effective dose exposure of 1.2 mSv is obtained using these reduced mAs values. It has to be differentiated between virtual colonoscopy for early detection of polyps and CRC in individual patients or as a screening examination of a large population. Virtual colonoscopy as a screening examination necessitates reduction of radiation dose, a high degree of automatisation in 3D reconstructions as well as the assessment of the entire mucosa. High risk patients, whom refuse fibreoptic colonoscopy should undergo virtual colonoscopy. Virtual colonoscopy has a good chance to become an accepted tool for general screening, if efficient dose reduction, complete visualization of the colon mucosa and automatisation of the post processing procedures can be achieved. (orig.) [de

  2. Adenoma detection in patients undergoing a comprehensive colonoscopy screening

    International Nuclear Information System (INIS)

    Raju, Gottumukkala S; Vadyala, Vikram; Slack, Rebecca; Krishna, Somashekar G; Ross, William A; Lynch, Patrick M; Bresalier, Robert S; Hawk, Ernest; Stroehlein, John R

    2013-01-01

    Measures shown to improve the adenoma detection during colonoscopy (excellent bowel preparation, cecal intubation, cap fitted colonoscope to examine behind folds, patient position change to optimize colon distention, trained endoscopy team focusing on detection of subtle flat lesions, and incorporation of optimum endoscopic examination with adequate withdrawal time) are applicable to clinical practice and, if incorporated are projected to facilitate comprehensive colonoscopy screening program for colon cancer prevention. To determine adenoma and serrated polyp detection rate under conditions designed to optimize quality parameters for comprehensive screening colonoscopy. Retrospective analysis of data obtained from a comprehensive colon cancer screening program designed to optimize quality parameters. Academic medical center. Three hundred and forty-three patients between the ages of 50 years and 75 years who underwent first screening colonoscopy between 2009 and 2011 among 535 consecutive patients undergoing colonoscopy. Comprehensive colonoscopy screening program was utilized to screen all patients. Cecal intubation was successful in 98.8% of patients. The Boston Bowel Preparation Scale for quality of colonoscopy was 8.97 (95% confidence interval [CI]; 8.94, 9.00). The rate of adenoma detection was 60% and serrated lesion (defined as serrated adenomas or hyperplastic polyps proximal to the splenic flexure) detection was 23%. The rate of precancerous lesion detection (adenomas and serrated lesions) was 66%. The mean number of adenomas per screening procedure was 1.4 (1.2, 1.6) and the mean number of precancerous lesions (adenomas or serrated lesions) per screening procedure was 1.6 (1.4, 1.8). Retrospective study and single endoscopist experience. A comprehensive colonoscopy screening program results in high-quality screening with high detection of adenomas, advanced adenomas, serrated adenomas, and multiple adenomas

  3. Quality is the key for emerging issues of population-based colonoscopy screening

    Directory of Open Access Journals (Sweden)

    Jin Young Yoon

    2018-01-01

    Full Text Available Colonoscopy is currently regarded as the gold standard and preferred method of screening for colorectal cancer (CRC. However, the benefit of colonoscopy screening may be blunted by low participation rates in population-based screening programs. Harmful effects of population-based colonoscopy screening may include complications induced by colonoscopy itself and by sedation, psychosocial distress, potential over-diagnosis, and socioeconomic burden. In addition, harmful effects of colonoscopy may increase with age and comorbidities. As the risk of adverse events in population-based colonoscopy screening may offset the benefit, the adverse events should be managed and monitored. To adopt population-based colonoscopy screening, consensus on the risks and benefits should be developed, focusing on potential harm, patient preference, socioeconomic considerations, and quality improvement of colonoscopy, as well as efficacy for CRC prevention. As suboptimal colonoscopy quality is a major pitfall of population-based screening, adequate training and regulation of screening colonoscopists should be the first step in minimizing variations in quality. Gastroenterologists should promote quality improvement, auditing, and training for colonoscopy in a population-based screening program.

  4. Trends in quality of screening colonoscopy in Austria.

    Science.gov (United States)

    Waldmann, Elisabeth; Gessl, Irina; Sallinger, Daniela; Jeschek, Philip; Britto-Arias, Martha; Heinze, Georg; Fasching, Elisabeth; Weiss, Werner; Gschwantler, Michael; Trauner, Michael; Ferlitsch, Monika

    2016-12-01

    Background and study aim: Screening colonoscopy only effectively prevents colorectal cancer if performed with high quality. The aim of this study was to analyze the detection rates of premalignant colorectal lesions in screening colonoscopies performed within a nationwide quality control program for screening colonoscopy in Austria. Methods: Data from electronic records of the screening program from its implementation in 2007 until December 2014 were analyzed in order to calculate detection rates for adenomas, advanced adenomas, polyps, and proximal lesions, and rates of cecal intubation, sedation, complications, and adequate bowel preparation. Results were evaluated to identify trends and changes in quality parameters over the 8-year study period. Results: During the study period, 301 endoscopists provided data from 159 246 screening colonoscopies. Mean age of screened individuals was 61.1 years, and 49.1 % were women. Significant increases over time were found for age- and sex-adjusted adenoma detection rates (ADRs), which increased from a mean of 22.2 % (SD 10.7 %) in 2007/2008 to 24.2 % (SD 11.6 %) in 2013/2014. On average, each endoscopist increased their individual ADR by + 1.5 percentage points per 2-year period (95 % confidence interval [CI] 0.9 - 2.2 percentage points; P  Austria between 2007 and 2014. Although, overall ADR increased significantly during the study period, there was a decrease in the rate of advanced adenoma detection. © Georg Thieme Verlag KG Stuttgart · New York.

  5. [Colonoscopy quality control as a requirement of colorectal cancer screening].

    Science.gov (United States)

    Quintero, Enrique; Alarcón-Fernández, Onofre; Jover, Rodrigo

    2013-11-01

    The strategies used in population-based colorectal screening strategies culminate in colonoscopy and consequently the success of these programs largely depends on the quality of this diagnostic test. The main factors to consider when evaluating quality are scientific-technical quality, safety, patient satisfaction, and accessibility. Quality indicators allow variability among hospitals, endoscopy units and endoscopists to be determined and can identify those not achieving recommended standards. In Spain, the working group for colonoscopy quality of the Spanish Society of Gastroenterology and the Spanish Society of Gastrointestinal Endoscopy have recently drawn up a Clinical Practice Guideline that contains the available evidence on the quality of screening colonoscopy, as well as the basic requirements that must be met by endoscopy units and endoscopists carrying out this procedure. The implementation of training programs and screening colonoscopy quality controls are strongly recommended to guarantee the success of population-based colorectal cancer screening. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  6. Examining the Impact of Latino Nativity, Migration, and Acculturation Factors on Colonoscopy Screening.

    Science.gov (United States)

    Costas-Muñiz, Rosario; Jandorf, Lina; Philip, Errol; Cohen, Noah; Villagra, Cristina; Sriphanlop, Pathu; Schofield, Elizabeth; DuHamel, Katherine

    2016-10-01

    Latinos are a diverse population comprised of multiple countries of origin with varying cultural profiles. This study examines differences in colonoscopy completion across place of birth and migration-related factors in a sample of predominantly Dominican and Puerto Rican Latinos living in New York City after receiving a recommendation for colonoscopy screening and navigation services. The sample included 702 Latinos recruited for two cancer screening projects targeting Latinos eligible for colonoscopy who seek healthcare in New York City. Participants completed a survey that included sociodemographic, health-related questions, psychosocial assessments and cancer screening practices, in Spanish or English. Migration, acculturation, and language factors were found to predict colonoscopy completion. The results indicated that Latinos born in the Dominican Republic and Central America were more likely to complete a screening colonoscopy than their counterparts born in the US. Further, those who emigrated at an older age, who have resided in the US for less than 20 years, preferred Spanish and those with lower US acculturation levels were also more likely to complete a screening colonoscopy. The findings suggest that Latinos who are less acculturated to the US are more likely to complete a screening colonoscopy after receiving a physician recommendation for colonoscopy screening. The results provide important information that can inform clinical practice and public health interventions. Continued attention to cultural and migration influences are important areas for cancer screening intervention development.

  7. Cost Effectiveness of Screening Colonoscopy Depends on Adequate Bowel Preparation Rates - A Modeling Study.

    Directory of Open Access Journals (Sweden)

    James Kingsley

    Full Text Available Inadequate bowel preparation during screening colonoscopy necessitates repeating colonoscopy. Studies suggest inadequate bowel preparation rates of 20-60%. This increases the cost of colonoscopy for our society.The aim of this study is to determine the impact of inadequate bowel preparation rate on the cost effectiveness of colonoscopy compared to other screening strategies for colorectal cancer (CRC.A microsimulation model of CRC screening strategies for the general population at average risk for CRC. The strategies include fecal immunochemistry test (FIT every year, colonoscopy every ten years, sigmoidoscopy every five years, or stool DNA test every 3 years. The screening could be performed at private practice offices, outpatient hospitals, and ambulatory surgical centers.At the current assumed inadequate bowel preparation rate of 25%, the cost of colonoscopy as a screening strategy is above society's willingness to pay (<$50,000/QALY. Threshold analysis demonstrated that an inadequate bowel preparation rate of 13% or less is necessary before colonoscopy is considered more cost effective than FIT. At inadequate bowel preparation rates of 25%, colonoscopy is still more cost effective compared to sigmoidoscopy and stool DNA test. Sensitivity analysis of all inputs adjusted by ±10% showed incremental cost effectiveness ratio values were influenced most by the specificity, adherence, and sensitivity of FIT and colonoscopy.Screening colonoscopy is not a cost effective strategy when compared with fecal immunochemical test, as long as the inadequate bowel preparation rate is greater than 13%.

  8. Colonoscopy conversion after flexible sigmoidoscopy screening: results from the UK bowel scope screening programme.

    Science.gov (United States)

    Siau, Keith; Yew, Andrew; Ishaq, Sauid; Jewes, Sarah; Shetty, Sharan S; Brookes, Matthew; Veitch, Andrew; McKaig, Brian; Murugananthan, Aravinth

    2017-12-05

    In the UK Bowel Scope screening programme (BSSP), patients progress to colonoscopy based on high-risk features on flexible sigmoidoscopy (FS). To assess practice of colonoscopy conversion and predictors of additional adenoma detection on colonoscopy. The Bowel Cancer Screening database was interrogated and collated with endoscopic and histological findings from patients undergoing colonoscopy following FS between August 2013 and August 2016. Multivariate analysis was performed to identify predictors of new adenomas. Wolverhampton bowel cancer screening centre, covering Wolverhampton, Dudley, Cannock and Walsall, with a combined catchment population of 1 million. This is the first UK site to fully roll-out BSSP. FS was performed on 11,711 patients, with an adenoma detection rate (ADR) of 8.5%, and conversion to colonoscopy in 421 (3.6%). The additional ADR at colonoscopy was 35.2%, with one additional malignant diagnosis (0.26%). The adenoma miss rate was 3.6%. On multivariate analysis, a polyp ≥10mm was the only high-risk indication associated with additional ADR at colonoscopy (odds ratio [OR] 3.68, 95% confidence interval [CI]:1.51-3.65, p<0.001), in addition to male gender (OR 2.36, 95% CI:1.46-3.83, p<0.001). Predictors of detection of a new adenoma ≥10mm included: villous adenoma (p=0.002), polyp≥10mm (p=0.007) and male gender (p=0.039). Presence of any conversion criteria was associated with the detection of any proximal adenoma (p<0.001) and adenoma ≥10mm (p=0.031). Male gender, ≥10mm polyps and villous-preponderant histology at FS were predictors of <10mm and ≥10mm adenomas at colonoscopy. Further data are required to assess the role for gender-based stratification of conversion criteria. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Evaluating screening colonoscopy quality in an uninsured urban population following patient navigation

    Directory of Open Access Journals (Sweden)

    Keith Naylor

    2017-03-01

    Full Text Available Patient navigation (PN increases screening colonoscopy completion in minority and uninsured populations. However, colonoscopy quality is under-reported in the setting of PN and quality indicators have often failed to meet benchmark standards. This study investigated screening colonoscopy quality indicators after year-one of a PN initiative targeting the medically uninsured. This was a retrospective analysis of 296 outpatient screening colonoscopies. Patients were 45 to 75 years of age with no history of bowel cancer, inflammatory bowel disease, or colorectal surgery. The screening colonoscopy quality indicators: adenoma detection rate (ADR, cecal intubation rate (CIR, and bowel preparation quality were compared in 89 uninsured Federally Qualified Health Center (FQHC patients who received PN and 207 University Hospital patients who received usual care. The FQHC PN and University Hospital cohorts were similar in female sex (69% vs. 70%; p = 0.861 and African American race (61% vs. 61%; p = 0.920. The FQHC PN cohort was younger (57 years vs. 60 years; p < 0.001. There was no difference in ADR (33% vs. 32%; p = 0.971 or CIR (96% vs. 95%; p = 0.900 comparing the FQHC PN and University Hospital cohorts. The FQHC PN patients had a greater likelihood of an optimal bowel preparation on multivariate logistic regression (odds ratio 4.17; 95% confidence interval 1.07 to 16.20. Uninsured FQHC patients who received PN were observed to have intra-procedure quality indicators that exceeded bench-mark standards for high-quality screening colonoscopy and were equivalent to those observed in an insured University Hospital patient population.

  10. Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in asymptomatic adults

    International Nuclear Information System (INIS)

    Pickhardt, Perry J.; Choi, J Richard; Hwang, Inku and others

    2004-01-01

    We evaluated the performance characteristics of computed tomographic (CT) virtual colonospy for the detection of colorectal neoplasia in an average-risk screening population. A total of 1233 symptomatic adults (mean age, 57.8 years) underwent same-day virtual and optical colonoscopy. Radiologists used the three-dimensional endoluminal display for the initial detection of polyps on CT virtual colonoscopy. For the initial examination of each colonic segment, the colonoscopists were unaware of the findings on virtual colonoscopy, which were revealed to them before any subsequent reexamination. The sensitivity and specificity of virtual colonoscopy and the sensitivity of optical colonoscopy were calculated with the use of the findings of the final, unblinded optical colonoscopy as the reference standard. The sensitivity of virtual colonoscopy for adenomatous polyps was 93.8 percent for polyps at least 10 mm in diameter, 93.9 percent for polyps at least 8 mm in diameter, and 88.7 percent for polyps at least 6 mm in diameter. The sensitivity of optical colonoscopy for adenomatous polyps was 87.5 percent, 91.5 percent, and 92.3 percent for the three sizes of polyps, respectively. The specificity of virtual colonoscopy for adenomatous polyps was 96.0 percent for polyps at least 10 mm in diameter, 92.2 percent for polyps at least 8 mm in diameter, and 79.6 percent for polyps at least 6 mm in diameter.Two polyps were malignant; both were detected on virtual colonoscopy, and one of them was missed on optical colonoscopy before the results on virtual colonoscopy were revealed. CT virtual colonoscopy with the use of a three-dimensional approach is an accurate screening method for the detection of colorectal neoplasia in symptomatic average-risk adults and compares favorably with optical colonoscopy in terms of the detection of clinically relevant lesions

  11. Delivering colonoscopy screening for low-income populations in Suffolk County: strategies, outcomes, and benchmarks.

    Science.gov (United States)

    Lane, Dorothy S; Messina, Catherine R; Cavanagh, Mary F; Anderson, Joseph C

    2013-08-01

    Current and pending legislation provides colorectal cancer screening reimbursement for previously uninsured populations. Colonoscopy is currently the screening method most frequently recommended by physicians for insured patients. The experience of the SCOPE (Suffolk County Preventive Endoscopy) demonstration project (Project SCOPE) at Stony Brook University Medical Center provides a model for delivering colonoscopy screening to low-income populations to meet anticipated increasing demands. Project SCOPE, based in the Department of Preventive Medicine, featured internal collaboration with the academic medical center's large gastroenterology practice and external collaboration with the Suffolk County Department of Health Services' network of community health centers. Colonoscopies were performed by faculty gastroenterologists or supervised fellows. Measures of colonoscopy performance were compared with quality indicators and differences between faculty and supervised fellows were identified. During a 40-month screening period, 800 initial colonoscopies were performed. Approximately 21% of women screened were found to have adenomatous polyps compared with 36% of men. Five cancers were detected. The majority of the population screened (70%) were members of minority populations. African American individuals had a higher percentage of proximally located adenomas (78%) compared with white individuals (65%) and Hispanics (49%), based on the location of the most advanced lesion. Hispanic individuals had a 36% lower risk of adenomas compared with white individuals. Performance measures including the percentage of procedures with adequate bowel preparation, cecum reached, scope withdrawal time, and adenoma detection rate met quality benchmarks when performed by either faculty or supervised fellows. Project SCOPE's operational strategies demonstrated a feasible method for an academic medical center to provide high-quality screening colonoscopy for low-income populations.

  12. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy.

    Science.gov (United States)

    Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y

    2015-09-04

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.

  13. Colometer: a real-time quality feedback system for screening colonoscopy.

    Science.gov (United States)

    Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N

    2012-08-28

    To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3

  14. Determinants of polyp Size in patients undergoing screening colonoscopy

    Directory of Open Access Journals (Sweden)

    Maisonneuve Patrick

    2011-09-01

    Full Text Available Abstract Background Pre-existing polyps, especially large polyps, are known to be the major source for colorectal cancer, but there is limited available information about factors that are associated with polyp size and polyp growth. We aim to determine factors associated with polyp size in different age groups. Methods Colonoscopy data were prospectively collected from 67 adult gastrointestinal practice sites in the United States between 2002 and 2007 using a computer-generated endoscopic report form. Data were transmitted to and stored in a central data repository, where all asymptomatic white (n = 78352 and black (n = 4289 patients who had a polyp finding on screening colonoscopy were identified. Univariate and multivariate analysis of age, gender, performance site, race, polyp location, number of polyps, and family history as risk factors associated with the size of the largest polyp detected at colonoscopy. Results In both genders, size of the largest polyp increased progressively with age in all age groups (P P Conclusions In both genders there is a significant increase in polyp size detected during screening colonoscopy with increasing age. Important additional risk factors associated with increasing polyp size are gender, race, polyp location, and number of polyps, with polyp multiplicity being the strongest risk factor. Previous family history of bowel cancer was not a risk factor.

  15. Narrative message targets within the decision-making process to undergo screening colonoscopy among Latinos: a qualitative study.

    Science.gov (United States)

    Hennelly, Marie Oliva; Sly, Jamilia R; Villagra, Cristina; Jandorf, Lina

    2015-06-01

    Colorectal cancer (CRC) is a preventable yet leading cause of cancer mortality among Latinos in the USA. Cultural targeting and narrative messaging are two strategies to increase the low screening colonoscopy rates among Latinos. This study identifies key messages for educational interventions aiming to increase screening colonoscopy used among Latinos and proposes a model to understand the relationship between factors involved in colonoscopy decision-making. Individual in-depth interviews were conducted with 12 Latino participants primarily of Puerto Rican descent on the topics of CRC knowledge, barriers and facilitators to colonoscopy use, and the use of narrative in colorectal health messaging. Knowledge about colorectal anatomy and the anesthesia component of colonoscopy procedure is low. Fear of procedure-related pain and fear of treatment-related burden following a cancer diagnosis are significant barriers to colonoscopy. Fear of disease-related suffering and death following a cancer diagnosis and fear of regret are strong facilitators and can be augmented by cancer narratives. Storytelling is commonly used in Latino culture and is an acceptable method to educate the Latino community about CRC screening via colonoscopy. Machismo is a unique barrier to colonoscopy for Latino men via homophobia and reluctance to seek healthcare. A preliminary model to understand factors in colonoscopy decision-making among Latinos is presented. Counseling practices and educational interventions that use culturally targeted narrative health messaging to mediate fears and increase colonoscopy knowledge may increase screening colonoscopy use among Latinos.

  16. Colonoscopy screening among US adults aged 40 or older with a family history of colorectal cancer.

    Science.gov (United States)

    Tsai, Meng-Han; Xirasagar, Sudha; Li, Yi-Jhen; de Groen, Piet C

    2015-05-21

    Colonoscopy screening reduces colorectal cancer (CRC) incidence and mortality. CRC screening is recommended at age 50 for average-risk people. Screening of first-degree relatives of CRC patients is recommended to begin at age 40 or 10 years before the age at diagnosis of the youngest relative diagnosed with CRC. CRC incidence has increased recently among younger Americans while it has declined among older Americans. The objective of this study was to determine whether first-degree relatives of CRC patients are being screened according to recommended guidelines. We studied colonoscopy screening rates among the US population reporting a CRC family history using 2005 and 2010 National Health Interview Survey data. Of 26,064 study-eligible respondents, 2,470 reported a CRC family history; of those with a family history, 45.6% had a colonoscopy (25.2% in 2005 and 65.8% 2010). The colonoscopy rate among first-degree relatives aged 40 to 49 in 2010 (38.3%) was about half that of first-degree relatives aged 50 or older (69.7%). First-degree relatives were nearly twice as likely as nonfirst-degree relatives to have a colonoscopy (adjusted odds ratio [AOR], 1.7; 95% confidence interval, 1.5-1.9), but those aged 40 to 49 were less likely to have a colonoscopy than those in older age groups (AOR, 2.6 for age 50-64; AOR, 3.6 for age ≥65). Interactions with age, insurance, and race/ethnicity were not significant. Having health insurance tripled the likelihood of screening. Despite a 5-fold increase in colonoscopy screening rates since 2005, rates among first-degree relatives younger than the conventional screening age have lagged. Screening promotion targeted to this group may halt the recent rising trend of CRC among younger Americans.

  17. Association Between Socioeconomic Status and Participation in Colonoscopy Screening Program in First Degree Relatives of Colorectal Cancer Patients.

    Science.gov (United States)

    Chouhdari, Arezoo; Yavari, Parvin; Pourhoseingholi, Mohammad Amin; Sohrabi, Mohammad-Reza

    2016-04-01

    Approximately 15% to 25% of colorectal cancer (CRC) cases have positive family history for disease. Colonoscopy screening test is the best way for prevention and early diagnosis. Studies have found that first degree relatives (FDRs) with low socioeconomic status are less likely to participate in colonoscopy screening program. The aim of this study is to determine the association between socioeconomic status and participation in colonoscopy screening program in FDRs. This descriptive cross-sectional, study has been conducted on 200 FDRs who were consulted for undergoing colonoscopy screening program between 2007 and 2013 in research institute for gastroenterology and liver disease of Shahid Beheshti University of Medical Sciences, Tehran, Iran. They were interviewed via phone by a valid questionnaire about socioeconomic status. For data analysis, chi-square, exact fisher and multiple logistic regression were executed by SPSS 19. The results indicated 58.5% participants underwent colonoscopy screening test at least once to the time of the interview. There was not an association between participation in colonoscopy screening program and socioeconomic status to the time of the interview in binomial analysis. But statistical significance between intention to participate and educational and income level were found. We found, in logistic regression analysis, that high educational level (Diploma and University degree in this survey) was a predictor to participate in colonoscopy screening program in FDRs. According to this survey low socioeconomic status is an important factor to hinder participation of FDRs in colonoscopy screening program. Therefore, planned interventions for elevation knowledge and attitude in FDRs with low educational level are necessary. Also, reducing colonoscopy test costs should be a major priority for policy makers.

  18. Reiki as a pain management adjunct in screening colonoscopy.

    Science.gov (United States)

    Bourque, Alda L; Sullivan, Mary E; Winter, Michael R

    2012-09-01

    The purpose of this study was to determine whether the use of Reiki decreases the amount of meperidine administered to patients undergoing screening colonoscopy. The literature review reveals limited studies to show whether Reiki has been able to decrease the amount of opioid the patient receives during screening colonoscopy. A chart review of 300 patients was conducted to obtain baseline average doses of meperidine patients received as the control. Following the chart review, 30 patients were recruited to the Reiki study. Twenty-five of the study arm patients received Reiki in conjunction with meperidine. Five randomly chosen study arm patients received placebo Reiki in conjunction with meperidine in an attempt to blind the clinicians to the treatment received by the patients. Results showed that there were no significant differences in meperidine administration between the patients in the chart review group (control) and the Reiki group. The study revealed that 16% who received Reiki, together with intravenous administration of conscious sedation, received less than 50 mg of meperidine. All the patients in the chart review group received more than 50 mg of meperidine. Results from this pilot study suggest that there may be a decrease in meperidine needed during screening colonoscopy when patients receive Reiki treatments before the procedure. A larger study powered to detect smaller medication differences is the next step in more accurately determining the effect of Reiki on pain management.

  19. Laparoscopic Splenectomy for Traumatic Splenic Injury after Screening Colonoscopy

    Directory of Open Access Journals (Sweden)

    Salim Abunnaja

    2012-09-01

    Full Text Available Colonoscopy is a widespread diagnostic and therapeutic procedure. The most common complications include bleeding and perforation. Splenic rupture following colonoscopy is rarely encountered and is most likely secondary to traction on the splenocolic ligament. Exploratory laparotomy and splenectomy is the most commonly employed therapeutic intervention for this injury reported in the literature. We present the case of a patient with this potentially fatal complication who was treated successfully at our institution. To our knowledge it is the first report in the literature of laparoscopic splenectomy as a successful minimally invasive treatment of splenic rupture following colonoscopy. The patient was a 62-year-old female who underwent screening colonoscopy with polypectomies at the cecum, descending colon and rectum. Immediately following the procedure she developed abdominal pain and had a syncopal episode. Clinical, laboratory and imaging findings were suggestive of hemoperitoneum and a ruptured spleen. A diagnostic laparoscopy was emergently performed and revealed a grade IV splenic laceration and hemoperitoneum. Laparoscopic splenectomy was completed safely and effectively. The patient’s postoperative recovery was uneventful. We conclude that splenic rupture after colonoscopy is a rare but dangerous complication. A high index of suspicion is required to recognize it early. Awareness of this potential complication can lead to optimal patient outcome. Laparoscopic splenectomy may be a feasible treatment option.

  20. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, Division of Medicine, London (United Kingdom); Ghanouni, Alex; Von Wagner, Christian [University College London, Health Behaviour Research Centre, Department of Epidemiology and Public Health, London (United Kingdom); Rees, Colin J. [Durham University School of Medicine, Pharmacy and Health, Durham (United Kingdom); Hewitson, Paul [University of Oxford, Health Services Research Unit, Nuffield Department of Population Health, Oxford (United Kingdom); Nickerson, Claire; Wright, Suzanne [Fulwood House, NHS Cancer Screening Programmes, Sheffield (United Kingdom)

    2017-03-15

    To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as complications. CTC and colonoscopy responses were compared using multilevel logistic regression. Of 67,114 subjects identified, 52,805 (79 %) responded. Understanding of test risks was lower for CTC (1712/1970 = 86.9 %) than colonoscopy (48783/50975 = 95.7 %, p < 0.0001). Overall, a slightly greater proportion of screenees found CTC unexpectedly uncomfortable (506/1970 = 25.7 %) than colonoscopy (10,705/50,975 = 21.0 %, p < 0.0001). CTC was tolerated well as a completion procedure for failed colonoscopy (unexpected discomfort; CTC = 26.3 %: colonoscopy = 57.0 %, p < 0.001). Post-procedural pain was equally common (CTC: 288/1970,14.6 %, colonoscopy: 7544/50,975,14.8 %; p = 0.55). Adverse event rates were similar in both groups (CTC: 20/2947 = 1.2 %; colonoscopy: 683/64,312 = 1.1 %), but generally less serious with CTC. Even though CTC was reserved for individuals either unsuitable for or unable to complete colonoscopy, we found only small differences in test-related discomfort. CTC was well tolerated as a completion procedure and was extremely safe. CTC can be delivered across a national screening programme with high patient satisfaction. (orig.)

  1. A Risk Prediction Index for Advanced Colorectal Neoplasia at Screening Colonoscopy.

    Science.gov (United States)

    Schroy, Paul C; Wong, John B; O'Brien, Michael J; Chen, Clara A; Griffith, John L

    2015-07-01

    Eliciting patient preferences within the context of shared decision making has been advocated for colorectal cancer screening. Risk stratification for advanced colorectal neoplasia (ACN) might facilitate more effective shared decision making when selecting an appropriate screening option. Our objective was to develop and validate a clinical index for estimating the probability of ACN at screening colonoscopy. We conducted a cross-sectional analysis of 3,543 asymptomatic, mostly average-risk patients 50-79 years of age undergoing screening colonoscopy at two urban safety net hospitals. Predictors of ACN were identified using multiple logistic regression. Model performance was internally validated using bootstrapping methods. The final index consisted of five independent predictors of risk (age, smoking, alcohol intake, height, and a combined sex/race/ethnicity variable). Smoking was the strongest predictor (net reclassification improvement (NRI), 8.4%) and height the weakest (NRI, 1.5%). Using a simplified weighted scoring system based on 0.5 increments of the adjusted odds ratio, the risk of ACN ranged from 3.2% (95% confidence interval (CI), 2.6-3.9) for the low-risk group (score ≤2) to 8.6% (95% CI, 7.4-9.7) for the intermediate/high-risk group (score 3-11). The model had moderate to good overall discrimination (C-statistic, 0.69; 95% CI, 0.66-0.72) and good calibration (P=0.73-0.93). A simple 5-item risk index based on readily available clinical data accurately stratifies average-risk patients into low- and intermediate/high-risk categories for ACN at screening colonoscopy. Uptake into clinical practice could facilitate more effective shared decision-making for CRC screening, particularly in situations where patient and provider test preferences differ.

  2. Quality Assessment of Colonoscopy Reporting: Results from a Statewide Cancer Screening Program

    Directory of Open Access Journals (Sweden)

    Jun Li

    2010-01-01

    Full Text Available This paper aimed to assess quality of colonoscopy reports and determine if physicians in practice were already documenting recommended quality indicators, prior to the publication of a standardized Colonoscopy Reporting and Data System (CO-RADS in 2007. We examined 110 colonoscopy reports from 2005-2006 through Maryland Colorectal Cancer Screening Program. We evaluated 25 key data elements recommended by CO-RADS, including procedure indications, risk/comorbidity assessments, procedure technical descriptions, colonoscopy findings, specimen retrieval/pathology. Among 110 reports, 73% documented the bowel preparation quality and 82% documented specific cecal landmarks. For the 177 individual polyps identified, information on size and morphology was documented for 87% and 53%, respectively. Colonoscopy reporting varied considerately in the pre-CO-RADS period. The absence of key data elements may impact the ability to make recommendations for recall intervals. This paper provides baseline data to assess if CO-RADS has an impact on reporting and how best to improve the quality of reporting.

  3. A Benchmark for Endoluminal Scene Segmentation of Colonoscopy Images

    Directory of Open Access Journals (Sweden)

    David Vázquez

    2017-01-01

    Full Text Available Colorectal cancer (CRC is the third cause of cancer death worldwide. Currently, the standard approach to reduce CRC-related mortality is to perform regular screening in search for polyps and colonoscopy is the screening tool of choice. The main limitations of this screening procedure are polyp miss rate and the inability to perform visual assessment of polyp malignancy. These drawbacks can be reduced by designing decision support systems (DSS aiming to help clinicians in the different stages of the procedure by providing endoluminal scene segmentation. Thus, in this paper, we introduce an extended benchmark of colonoscopy image segmentation, with the hope of establishing a new strong benchmark for colonoscopy image analysis research. The proposed dataset consists of 4 relevant classes to inspect the endoluminal scene, targeting different clinical needs. Together with the dataset and taking advantage of advances in semantic segmentation literature, we provide new baselines by training standard fully convolutional networks (FCNs. We perform a comparative study to show that FCNs significantly outperform, without any further postprocessing, prior results in endoluminal scene segmentation, especially with respect to polyp segmentation and localization.

  4. Screening colonoscopy for the detection of neoplastic lesions in asymptomatic HIV-infected subjects.

    Science.gov (United States)

    Bini, E J; Green, B; Poles, M A

    2009-08-01

    Although non-AIDS defining malignancies are rapidly increasing as HIV-infected subjects live longer, little is know about the results of screening for colonic neoplasms (adenomatous polyps and adenocarcinomas) in this population. We conducted a screening colonoscopy study to determine the prevalence of colonic neoplasms in 136 asymptomatic HIV-infected subjects >or=50 years of age and 272 asymptomatic uninfected control subjects matched for age, sex, and family history of colorectal cancer. Advanced neoplasms were defined as adenomas >or=10 mm or any adenoma, regardless of size, with villous histology, high-grade dysplasia, or adenocarcinoma. The prevalence of neoplastic lesions was significantly higher in HIV-infected subjects than in control subjects (62.5% vs 41.2%, pscreening colonoscopy should be offered to HIV-infected subjects, but the age of initiation and the optimal frequency of screening require further study.

  5. Colonoscopy

    Science.gov (United States)

    ... regular activities the next day. Avoid driving, operating machinery, drinking alcohol, and making important decisions for at ... of colonoscopy may include any of the following: Heavy or ongoing bleeding from biopsy or removal of ...

  6. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, Andrew A.; Ghanouni, Alex; Rees, Colin J.; Hewitson, Paul; Nickerson, Claire; Wright, Suzanne; Taylor, Stuart A.; Halligan, Steve; von Wagner, Christian

    2016-01-01

    Objective To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Methods Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as compl...

  7. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, A. A.; Ghanouni, A.; Rees, C. J.; Hewitson, P.; Nickerson, C.; Wright, S.; Taylor, S. A.; Halligan, S.; von Wagner, C.

    2017-01-01

    OBJECTIVE: To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. METHODS: Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as com...

  8. Virtual colonoscopy: a new alternative for colorectal neoplasm screening?; Colonoscopia virtual: una nueva alternativa en el screening del cancer colorrectal?

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, P; Castiglioni, R; Sanchez, F; Capunay, C; Mazzuco, J; Carrascosa, J [Diagnostico Maipu, Vicente Lopez, Buenos Aires (Argentina)

    2000-07-01

    The authors presents 46 patients-series with virtual colonoscopy. The findings obtained through virtual colonoscopy were divided into 7 groups: 1) Single polypoid lesion (9 patients); 2) Associated polypoid lesions (11 patients); 3) Tumoral stenosis without synchronic lesion (3 patients); 4) Tumoral stenosis with synchronic lesion (6 patients); 5) Non-tumoral stenosis (4 patients); 6) Normal studies (2 patients); 7) Patients excluded due to wrong preparation (11 patients). We concluded that the virtual colonoscopy is a valid alternative in the screening of the colorectal pathology, showing some advantages when compared to the usual studies, since it is non-invasive, does not require sedation, and allows the staging of the neoplasm. (author)

  9. Effectiveness of screening colonoscopy in reducing the risk of death from right and left colon cancer: a large community-based study.

    Science.gov (United States)

    Doubeni, Chyke A; Corley, Douglas A; Quinn, Virginia P; Jensen, Christopher D; Zauber, Ann G; Goodman, Michael; Johnson, Jill R; Mehta, Shivan J; Becerra, Tracy A; Zhao, Wei K; Schottinger, Joanne; Doria-Rose, V Paul; Levin, Theodore R; Weiss, Noel S; Fletcher, Robert H

    2018-02-01

    Screening colonoscopy's effectiveness in reducing colorectal cancer mortality risk in community populations is unclear, particularly for right-colon cancers, leading to recommendations against its use for screening in some countries. This study aimed to determine whether, among average-risk people, receipt of screening colonoscopy reduces the risk of dying from both right-colon and left-colon/rectal cancers. We conducted a nested case-control study with incidence-density matching in screening-eligible Kaiser Permanente members. Patients who were 55-90 years old on their colorectal cancer death date during 2006-2012 were matched on diagnosis (reference) date to controls on age, sex, health plan enrolment duration and geographical region. We excluded patients at increased colorectal cancer risk, or with prior colorectal cancer diagnosis or colectomy. The association between screening colonoscopy receipt in the 10-year period before the reference date and colorectal cancer death risk was evaluated while accounting for other screening exposures. We analysed 1747 patients who died from colorectal cancer and 3460 colorectal cancer-free controls. Compared with no endoscopic screening, receipt of a screening colonoscopy was associated with a 67% reduction in the risk of death from any colorectal cancer (adjusted OR (aOR)=0.33, 95% CI 0.21 to 0.52). By cancer location, screening colonoscopy was associated with a 65% reduction in risk of death for right-colon cancers (aOR=0.35, CI 0.18 to 0.65) and a 75% reduction for left-colon/rectal cancers (aOR=0.25, CI 0.12 to 0.53). Screening colonoscopy was associated with a substantial and comparably decreased mortality risk for both right-sided and left-sided cancers within a large community-based population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Virtual colonoscopy: clinical application

    International Nuclear Information System (INIS)

    Laghi, A.

    2005-01-01

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  11. Virtual colonoscopy: clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, A. [Univ. of Rome La Sapienza, Polo Didattico Pontino, Latina (Italy)

    2005-11-15

    Virtual colonoscopy (VC), also known as computed tomography Colonography (CTC), is a non-invasive test for the examination of the colon based on volumetric, thin-collimation CT acquisition of a cleansed and air-distended colon. The technique is easy, less labour-intensive than barium enema and conventional colonoscopy, and is inherently safer. Several studies demonstrate the ability of VC in the detection of colonic neoplastic lesions, not only large carcinomas, but also polyps. Currently, the most widely accepted clinical indication is incomplete or unsuccessful colonoscopy, which may be the result of redundant colon, patient intolerance to the procedure, spasm not resolving even with the use of spasmolytics, obstructing colo-rectal cancer. VC is also used to detect cancer in frail and immobile patients to avoid sedation during colonoscopy or the turning required during barium enema. The use of VC in patients under surveillance following colo-rectal cancer surgery is under investigation. Further studies are necessary in order to assess the cost-effectiveness of this approach. For colo-rectal cancer screening, a practical approach is to consider VC as a currently credible alternative screening method and as a reasonable alternative to the other colo-rectal cancer screening tests when a patient is unable or unwilling to undergo conventional colonoscopy. (orig.)

  12. The Offer of Advanced Imaging Techniques Leads to Higher Acceptance Rates for Screening Colonoscopy - a Prospective Study.

    Science.gov (United States)

    Albrecht, Heinz; Gallitz, Julia; Hable, Robert; Vieth, Michael; Tontini, Gian Eugenio; Neurath, Markus Friedrich; Riemann, Jurgen Ferdinand; Neumann, Helmut

    2016-01-01

    Colonoscopy plays a fundamental role in early diagnosis and management of colorectal cancer and requires public and professional acceptance to ensure the ongoing success of screening programs. The aim of the study was to prospectively assess whether patient acceptance rates to undergo screening colonoscopy could be improved by the offer of advanced imaging techniques. Overall, 372 randomly selected patients were prospectively included. A standardized questionnaire was developed that inquired of the patients their knowledge regarding advanced imaging techniques. Second, several media campaigns and information events were organized reporting about advanced imaging techniques, followed by repeated evaluation. After one year the evaluation ended. At baseline, 64% of the patients declared that they had no knowledge about new endoscopic methods. After twelve months the overall grade of information increased significantly from 14% at baseline to 34%. The percentage of patients who decided to undergo colonoscopy because of the offer of new imaging methods also increased significantly from 12% at baseline to 42% after 12 months. Patients were highly interested in the offer of advanced imaging techniques. Knowledge about these techniques could relatively easy be provided using local media campaigns. The offer of advanced imaging techniques leads to higher acceptance rates for screening colonoscopies.

  13. Effectiveness of a multimedia-based educational intervention for improving colon cancer literacy in screening colonoscopy patients.

    Science.gov (United States)

    Hassinger, James P; Holubar, Stefan D; Pendlimari, Rajesh; Dozois, Eric J; Larson, David W; Cima, Robert R

    2010-09-01

    Limited data exist regarding colon cancer literacy in screening colonoscopy patients. We aimed to prospectively assess baseline colon cancer literacy and to determine whether a multimedia educational intervention was associated with improved colon cancer literacy. Colon cancer literacy was assessed in a convenience sample of colonoscopy patients before and after educational intervention. Statistically significant associations with colon cancer literacy scores were assessed by use of multivariate logistic regression analysis. Results are frequency (proportion), mean +/- SD, and odds ratio (OR (95% CI)). Seventy-three subjects participated: mean age, 57 +/- 12 years, 35 (48%) were women, 41 (57%) had a college degree, 43 (59%) had prior colonoscopy, 21 (29%) were accompanying family, and 16 (22%) were health care employees. Multivariate factors associated with a higher baseline colon cancer literacy score included health care employee status (7.9 (95% CI, 1.6-63); P = .02) and family colon cancer history (5.3 (95% CI, 1.3-25); P = .02). After multimedia education, mean scores improved from 53% +/- 23% to 88% +/- 12% (Delta = 35%; P screening colonoscopy. Multimedia-based educational intervention was an effective, satisfying strategy for addressing cancer-specific knowledge deficit in laypersons.

  14. Prevalence of colon polyps detected by colonoscopy screening in asymptomatic black and white patients

    Science.gov (United States)

    Lieberman, David; Holub, Jennifer; Moravec, Matthew; Eisen, Glenn; Peters, Dawn; Morris, Cynthia

    2013-01-01

    Context Compared to whites, Black men and women have a higher incidence and mortality from colorectal cancer and may develop cancer at a younger age. Colorectal cancer screening might be less effective in Blacks, if there are racial differences in the age-adjusted prevalence and location of cancer precursor lesions. Objectives To determine and compare the prevalence rates and location of polyp(s) >9mm in asymptomatic Blacks and whites who receive colonoscopy screening. Design, Setting, and Patients Colonoscopy data were prospectively collected from 67 practice sites in the United States using a computerized endoscopic report generator from 2004–2005. Data were transmitted to a central data repository, where all asymptomatic whites (n = 80,061) and Blacks (n = 5464) who received screening colonoscopy were identified. Main outcome measures Prevalence and location of polyp(s) >9mm, adjusted for age, gender, and family history of colorectal cancer in a multivariate analysis. Results Both Black men and women had a higher prevalence of polyp(s) >9mm (7.7 versus 6.2%; p 9mm (OR 1.133; 95% CI 0.93,1.38). However, in a sub-analysis of patients over age 60 years, proximal polyps >9mm were more likely in Black men (p = 0.026) and women (p9mm, and Black over age 60 years are more likely to proximal polyps >9mm. PMID:18812532

  15. Active Choice and Financial Incentives to Increase Rates of Screening Colonoscopy-A Randomized Controlled Trial.

    Science.gov (United States)

    Mehta, Shivan J; Feingold, Jordyn; Vandertuyn, Matthew; Niewood, Tess; Cox, Catherine; Doubeni, Chyke A; Volpp, Kevin G; Asch, David A

    2017-11-01

    Behavioral economic approaches could increase uptake for colorectal cancer screening. We performed a randomized controlled trial of 2245 employees to determine whether an email containing a phone number for scheduling (control), an email with the active choice to opt in or opt out (active choice), or the active choice email plus a $100 incentive (financial incentive) increased colonoscopy completion within 3 months. Higher proportions of participants in the financial incentive group underwent screening (3.7%) than in the control (1.6%) or active choice groups (1.5%) (P = .01 and P < .01). We found no difference in uptake of screening between the active choice and control groups (P = .88). The $100 conditional incentive modestly but significantly increased colonoscopy use. ClinicalTrials.gov no: NCT02660671. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  16. The association of colonoscopy quality indicators with the detection of screen-relevant lesions, adverse events, and postcolonoscopy cancers in an asymptomatic Canadian colorectal cancer screening population.

    Science.gov (United States)

    Hilsden, Robert J; Dube, Catherine; Heitman, Steven J; Bridges, Ronald; McGregor, S Elizabeth; Rostom, Alaa

    2015-11-01

    Although several quality indicators of colonoscopy have been defined, quality assurance activities should be directed at the measurement of quality indicators that are predictive of key screening colonoscopy outcomes. The goal of this study was to examine the association among established quality indicators and the detection of screen-relevant lesions (SRLs), adverse events, and postcolonoscopy cancers. Historical cohort study. Canadian colorectal cancer screening center. A total of 18,456 asymptomatic men and women ages 40 to 74, at either average risk or increased risk for colorectal cancer because of a family history, who underwent a screening colonoscopy from 2008 to 2010. Using univariate and multivariate analyses, we explored the association among procedural quality indicators and 3 colonoscopy outcomes: detection of SRLs, adverse events, and postcolonoscopy cancers. The crude rates of SRLs, adverse events, and postcolonoscopy cancers were 240, 6.44, and .54 per 1000 colonoscopies, respectively. Several indicators, including endoscopist withdrawal time (OR, 1.3; 95% CI, 1.2-1.4) and cecal intubation rate (OR, 13.9; 95% CI, 1.9-96.9), were associated with the detection of SRLs. No quality indicator was associated with the risk of adverse events. Endoscopist average withdrawal time over 6 minutes (OR, .12; 95% CI, .002-.85) and SRL detection rate over 20% (OR, .17; 95% CI, .03-.74) were associated with a reduced risk of postcolonoscopy cancers. Single-center study. Quality assurance programs should prioritize the measurement of endoscopist average withdrawal time and adenoma (SRL) detection rate. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  17. Combined colonoscopy and endometrial biopsy cancer screening results in women with Lynch syndrome.

    Science.gov (United States)

    Nebgen, Denise R; Lu, Karen H; Rimes, Sue; Keeler, Elizabeth; Broaddus, Russell; Munsell, Mark F; Lynch, Patrick M

    2014-10-01

    Endometrial biopsy (EMBx) and colonoscopy performed under the same sedation is termed combined screening and has been shown to be feasible and to provide a less painful and more satisfactory experience for women with Lynch syndrome (LS). However, clinical results of these screening efforts have not been reported. The purpose of this study was to evaluate the long-term clinical outcomes and patient compliance with serial screenings over the last 10.5 years. We retrospectively analyzed the data for 55 women with LS who underwent combined screening every 1-2 years between 2002 and 2013. Colonoscopy and endometrial biopsy were performed by a gastroenterologist and a gynecologist, with the patient under conscious sedation. Out of 111 screening visits in these 55 patients, endometrial biopsies detected one simple hyperplasia, three complex hyperplasia, and one endometrioid adenocarcinoma (FIGO Stage 1A). Seventy-one colorectal polyps were removed in 29 patients, of which 29 were tubular adenomas. EMBx in our study detected endometrial cancer in 0.9% (1/111) of surveillance visits, and premalignant hyperplasia in 3.6% (4/111) of screening visits. No interval endometrial or colorectal cancers were detected. Combined screening under sedation is feasible and less painful than EMBx alone. Our endometrial pathology detection rates were comparable to yearly screening studies. Our results indicate that screening of asymptomatic LS women with EMBx every 1-2 years, rather than annually, is effective in the early detection of (pre)cancerous lesions, leading to their prompt definitive management, and potential reduction in endometrial cancer. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Use, appropriateness, and diagnostic yield of screening colonoscopy: an international observational study (EPAGE)

    DEFF Research Database (Denmark)

    Burnand, B; JK, Harris; Wietlisbach, V

    2006-01-01

    was asked of all centers, it is possible that not all consecutive patients were included. Participating centers were a convenience sample and thus may not be representative. CONCLUSIONS: About 1 of 10 colonoscopies were performed for screening, preferentially in middle-aged individuals. A higher diagnostic...

  19. [Acceptance and willingness-to-pay for colorectal colonoscopy screening among high-risk populations for colorectal cancer in urban China].

    Science.gov (United States)

    Shi, Jufang; Huang, Huiyao; Guo, Lanwei; Ren, Jiansong; Ren, Ying; Lan, Li; Zhou, Qi; Mao, Ayan; Qi, Xiao; Liao, Xianzhen; Liu, Guoxiang; Bai, Yana; Cao, Rong; Liu, Yuqin; Wang, Yuanzheng; Gong, Jiyong; Li, Ni; Zhang, Kai; He, Jie; Dai, Min

    2015-05-01

    To survey the acceptance and willingness-to-pay for colorectal cancer colonoscopy screening among high risk populations in urban China. From 2012 to 2013, a Cancer Screening Program in Urban China (CanSPUC) was initiated in 9 provinces, the current survey was conducted among those participants who were evaluated as "high risk for colorectal cancer" by a risk-factor-evaluation-model (community-based) and then went through a colonoscopy screening procedure (hospital-based). All the data were obtained through a questionnaire-based interview (face-to-face or self-completed), mainly focusing on the acceptance and willingness-to-pay of the participants for colorectal colonoscopy screening. The current analysis included a total of 1 624 participants, with an median age of 55.0 years (P25 = 49.0, P75 = 61.0 years) and an annual income per capita of 17 thousand (range: 10-25 thousand) Chinese Yuan (CNY), 42.8% (695/1 624) of whom were males. Of all the participants, 87.0% (1 414/1 624) could totally or substantially accept the colonoscopy screening, particularly in those at higher education level (junior high school: OR = 0.34, 95% CI: 0.22-0.52; high school OR = 0.41, 95% CI: 0.26-0.66; college or over OR = 0.35, 95% CI: 0.20-0.59). Of all the participants, 13.0% (210/1 624) could not or hardly accept it, particularly in those with older age (60-69 years) (OR = 1.48, 95% CI: 1.06-2.07), not in marriage (OR = 2.15, 95% CI: 1.25-3.70) or with family member(s) to raise (OR = 1.60, 95% CI: 1.17-2.20). 1 388 (85.5%) of all the participants had willingness-to-pay for a long-term colonoscopy screening service, particularly in those working in public (OR = 0.61, 95% CI: 0.44-0.84) or enterprise sectors (OR = 0.60, 95% CI: 0.38-0.94), but 82.3% (1 141/1 386) of whom would only pay less than 100 CNY; 14.5% (236/1 624) of total had no willingness-to-pay, particularly in those living in areas with moderate (OR = 4.08, 95% CI: 2.75-6.33) or high GDP per capita (OR = 3.26, 95% CI: 2

  20. The big picture: does colonoscopy work?

    Science.gov (United States)

    Hewett, David G; Rex, Douglas K

    2015-04-01

    Colonoscopy for average-risk colorectal cancer screening has transformed the practice of gastrointestinal medicine in the United States. However, although the dominant screening strategy, its use is not supported by randomized controlled trials. Observational data do support a protective effect of colonoscopy and polypectomy on colorectal cancer incidence and mortality, but the level of protection in the proximal colon is variable and operator-dependent. Colonoscopy by high-level detectors remains highly effective, and ongoing quality improvement initiatives should consider regulatory factors that motivate changes in physician behavior. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Modestly increased use of colonoscopy when copayments are waived.

    Science.gov (United States)

    Khatami, Shabnam; Xuan, Lei; Roman, Rolando; Zhang, Song; McConnel, Charles; Halm, Ethan A; Gupta, Samir

    2012-07-01

    Colorectal cancer (CRC) screening with colonoscopy often requires expensive copayments from patients. The 2010 Patient Protection and Affordable Care Act mandated elimination of copayments for CRC screening, including colonoscopy, but little is known about the effects of copayment elimination on use. The University of Texas employee, retiree, and dependent health plan instituted and promoted a waiver of copayments for screening colonoscopies in fiscal year (FY) 2009; we examined the effects of removing cost sharing on colonoscopy use. We conducted a retrospective cohort study of 59,855 beneficiaries of the University of Texas employee, retiree, and dependent health plan, associated with 16 University of Texas health and nonhealth campuses, ages 50-64 years at any point in FYs 2002-2009 (267,191 person-years of follow-up evaluation). The primary outcome was colonoscopy incidence among individuals with no prior colonoscopy. We compared the age- and sex-standardized incidence ratios for colonoscopy in FY 2009 (after the copayment waiver) with the expected incidence for FY 2009, based on secular trends from years before the waiver. The annual incidence of colonoscopy increased to 9.5% after the copayment was waived, compared with an expected incidence of 8.0% (standardized incidence ratio, 1.18; 95% confidence interval, 1.14-1.23; P screening results in a statistically significant, but modest (1.5%), increase in use. Additional strategies beyond removing financial disincentives are needed to increase use of CRC screening. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

  2. Cecal intubation rate during colonoscopy at a tertiary hospital in ...

    African Journals Online (AJOL)

    Background: Colonoscopy is useful in the diagnosis, treatment of colorectal diseases, and for colorectal cancer screening program. Complete colonoscopy is therefore crucial for the success of any screening program. One important measure of the quality of colonoscopy is the cecal intubation rate (CIR). Aim: This was to ...

  3. What to Expect During a Colonoscopy

    Medline Plus

    Full Text Available ... for Clinical Research and Education, underscores the lifesaving importance of colorectal screening by colonoscopy. The video instills confidence in patients about the effectiveness, safety and importance of colonoscopy. Featuring the experience of a female ...

  4. Racial/Ethnic Minorities Ineligible for Direct Access Colonoscopy (DAC): Identifying Patients Who Fall Through the Cracks.

    Science.gov (United States)

    Miller, Sarah J; Sly, Jamilia R; Itzkowitz, Steven H; Jandorf, Lina

    2015-03-01

    Patients ineligible for direct access colonoscopy (DAC) are typically referred for a pre-colonoscopy consultation with gastroenterology (GI). However, the referral from primary care to GI creates the potential for patients to drop out of treatment. The primary objective of the current study was to examine the proportion of participants deemed ineligible for DAC that (1) attended an appointment with GI and (2) completed a screening colonoscopy. The second aim of the study was to examine predictors of screening colonoscopy adherence. Participants (N = 144) were average-risk patients who received a primary care referral for a screening colonoscopy and were deemed ineligible for DAC between 2008 and 2012. Following the primary care visit, participants completed a questionnaire that assessed demographics and psychological factors. Medical chart review determined whether participants completed the screening colonoscopy via the GI referral. Of the 144 participants, only 19 (13 %) completed the screening colonoscopy via the GI referral. Multiple regression analyses revealed that decisional balance was the only unique predictor of screening colonoscopy adherence. Patients deemed ineligible for DAC are highly unlikely to complete a screening colonoscopy. Interventions are needed to increase screening colonoscopy adherence in this vulnerable population.

  5. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    Science.gov (United States)

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P 90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  6. High Definition Colonoscopy Combined with i-SCAN Imaging Technology Is Superior in the Detection of Adenomas and Advanced Lesions Compared to High Definition Colonoscopy Alone.

    Science.gov (United States)

    Bowman, Erik A; Pfau, Patrick R; Mitra, Arnab; Reichelderfer, Mark; Gopal, Deepak V; Hall, Benjamin S; Benson, Mark E

    2015-01-01

    Background. Improved detection of adenomatous polyps using i-SCAN has mixed results in small studies. Utility of i-SCAN as a primary surveillance modality for colorectal cancer screening during colonoscopy is uncertain. Aim. Comparing high definition white light endoscopy (HDWLE) to i-SCAN in their ability to detect adenomas during colonoscopy. Methods. Prospective cohort study of 1936 average risk patients who had a screening colonoscopy at an ambulatory procedure center. Patients underwent colonoscopy with high definition white light endoscopy withdrawal versus i-SCAN withdrawal during endoscopic screening exam. Primary outcome measurement was adenoma detection rate for i-SCAN versus high definition white light endoscopy. Secondary measurements included polyp size, pathology, and morphology. Results. 1007 patients underwent colonoscopy with i-SCAN and 929 with HDWLE. 618 adenomas were detected in the i-SCAN group compared to 402 in the HDWLE group (p definition white light endoscopy.

  7. Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels.

    Science.gov (United States)

    Tapia-Siles, Silvia C; Coleman, Stuart; Cuschieri, Alfred

    2016-02-01

    Previous reports have described several candidates, which have the potential to replace colonoscopy, but to date, there is still no device capable of fully replacing flexible colonoscopy in the management of colonic disorders and for mass adult population screening for asymptomatic colorectal cancer. NASA developed the TRL methodology to describe and define the stages of development before use and marketing of any device. The definitions of the TRLS used in the present review are those formulated by "The US Department of Defense Technology Readiness Assessment Guidance" but adapted to micro-robots for colonoscopy. All the devices included are reported in scientific literature. They were identified by a systematic search in Web of Science, PubMed and IEEE Xplore amongst other sources. Devices that clearly lack the potential for full replacement of flexible colonoscopy were excluded. The technological salient features of all the devices included for assessment are described briefly, with particular focus on device propulsion. The devices are classified according to the TRL criteria based on the reported information. An analysis is next undertaken of the characteristics and salient features of the devices included in the review: wireless/tethered devices, data storage-transmission and navigation, additional functionality, residual technology challenges and clinical and socio-economical needs. Few devices currently possess the required functionality and performance to replace the conventional colonoscopy. The requirements, including functionalities which favour the development of a micro-robot platform to replace colonoscopy, are highlighted.

  8. Cultural, economic, and psychological predictors of colonoscopy in a national sample.

    Science.gov (United States)

    Halbert, Chanita Hughes; Barg, Frances K; Guerra, Carmen E; Shea, Judy A; Armstrong, Katrina; Ferguson, Monica; Weathers, Benita; Coyne, James; Troxel, Andrea B

    2011-11-01

    Although colorectal cancer (CRC) is the second leading cause of cancer death among adults in the US and colonoscopy is efficacious in reducing morbidity and mortality from CRC, screening rates are sub-optimal. Understanding the socioeconomic, cultural, and health care context within which decisions about colonoscopy are made allows physicians to address patients' most salient beliefs and values and other constraints when making screening recommendations. To evaluate the direct and interactive effects of socioeconomics, health care variables, psychological characteristics, and cultural values on colonoscopy use. National survey completed between January-August 2009 in a random sample of African American, white, and Hispanic adults ages 50-75 without cancer (n = 582). Self-reported colonoscopy use. Only 59% of respondents reported having a colonoscopy. The likelihood of colonoscopy increased with having health insurance (OR = 2.82, 95% CI = 1.24, 6.43, p = 0.004), and increasing age (OR = 1.40, 95% CI = 1.11, 1.77, p = 0.001). In addition, respondents with greater self-efficacy were more likely to have a colonoscopy (OR = 2.41, 95% CI = 1.35, 4.29, p = 0.003). Programs that help patients to overcome access and psychological barriers to screening are needed.

  9. The discriminatory capability of existing scores to predict advanced colorectal neoplasia: a prospective colonoscopy study of 5,899 screening participants.

    Science.gov (United States)

    Wong, Martin C S; Ching, Jessica Y L; Ng, Simpson; Lam, Thomas Y T; Luk, Arthur K C; Wong, Sunny H; Ng, Siew C; Ng, Simon S M; Wu, Justin C Y; Chan, Francis K L; Sung, Joseph J Y

    2016-02-03

    We evaluated the performance of seven existing risk scoring systems in predicting advanced colorectal neoplasia in an asymptomatic Chinese cohort. We prospectively recruited 5,899 Chinese subjects aged 50-70 years in a colonoscopy screening programme(2008-2014). Scoring systems under evaluation included two scoring tools from the US; one each from Spain, Germany, and Poland; the Korean Colorectal Screening(KCS) scores; and the modified Asia Pacific Colorectal Screening(APCS) scores. The c-statistics, sensitivity, specificity, positive predictive values(PPVs), and negative predictive values(NPVs) of these systems were evaluated. The resources required were estimated based on the Number Needed to Screen(NNS) and the Number Needed to Refer for colonoscopy(NNR). Advanced neoplasia was detected in 364 (6.2%) subjects. The German system referred the least proportion of subjects (11.2%) for colonoscopy, whilst the KCS scoring system referred the highest (27.4%). The c-statistics of all systems ranged from 0.56-0.65, with sensitivities ranging from 0.04-0.44 and specificities from 0.74-0.99. The modified APCS scoring system had the highest c-statistics (0.65, 95% C.I. 0.58-0.72). The NNS (12-19) and NNR (5-10) were similar among the scoring systems. The existing scoring systems have variable capability to predict advanced neoplasia among asymptomatic Chinese subjects, and further external validation should be performed.

  10. Cecal Intubation Rate During Colonoscopy at a Tertiary Hospital in ...

    African Journals Online (AJOL)

    2016-06-14

    Jun 14, 2016 ... diseases, and for colorectal cancer screening program. Complete colonoscopy is therefore crucial for the success of any screening program. One important measure of the quality of colonoscopy is the cecal intubation rate (CIR). Aim: This was to assess the CIR at our endoscopy unit and evaluate the factors ...

  11. Colonoscopy training for nurse endoscopists : A feasibility study

    NARCIS (Netherlands)

    Koornstra, Jan J.; Corporaal, Sietske; Giezen-Beintema, Wiesje M.; de Vries, Sietske E.; van Dullemen, Hendrik M.

    Background: Screening by using colonoscopy is recommended in many countries to reduce the risk of death from colorectal cancer. Given the limited supply of medical endoscopists, nurse endoscopists may represent an economic alternative. Objective: To develop a colonoscopy training program for nurse

  12. STUDY ON VIRTUAL COLONOSCOPY

    Directory of Open Access Journals (Sweden)

    Aithagani Rama Chandraiah

    2016-10-01

    Full Text Available BACKGROUND Current options available in the investigations of colorectal carcinoma include screening using digital rectal examination, sigmoidoscopy, barium enema and fiberoptic colonoscopy, virtual colonoscopy. The aim of the study was to prospectively evaluate patient acceptance of virtual colonoscopy compared with that of conventional colonoscopy when performed in patients with or suspected of having colorectal disease. MATERIALS AND METHODS The study had been conducted on patients attending Department of Radiology for a period of 1 year. Patients with primary or secondary complaints of pain abdomen, lump in abdomen, bleeding per rectum, loose motions/constipation, altered bowel habits, loss of appetite and weight and anaemia, so total number of cases were 51. RESULTS In our study, the patients were in age groups of 21-70 years. Both sexes were represented in our study. Male preponderance was noted in 51 patients. Cases of adenoma were more commonly found 37 (72.78%. The sensitivity of the CT colonography for the polyps more than 10 mm is 100%, polyps 6-9 mm is 90%, less than 6 mm is 80%. Our study consists of 51 patients; among them, 30 patients showed acceptance for CT colonography, 10 patients for optical colonoscopy. Our study consists of 51 patients, the polyps (more than 10 mm detected in 2D viewing were 24, 2D and 3D viewing of 24, the polyps (less than 10 mm detected in 2D viewing were 15, 2D and 3D viewing were 17. 3D viewing resulted in increased sensitivity for identification of patients with larger polyps more than 1 cm, (70-85% sensitivity and patients with smaller polyps less than 1 cm (increased sensitivity 75-88%. CONCLUSIONS Multislice CT (64 colonography is a good alternative to other colorectal screening tests because it has high sensitivity for polyps 10 mm or more in diameter is relatively safe, clinical effective, minimally invasive, cost effective and filter for therapeutic optical colonoscopy.

  13. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  14. Screening colonoscopy participation in Turkish colorectal cancer patients and their first degree relatives.

    Science.gov (United States)

    Kilickap, Saadettin; Arslan, Cagatay; Rama, Dorina; Yalcin, Suayib

    2012-01-01

    This study aimed to research the awareness of screening colonoscopy (SC) among patients with colorectal cancer (CRC) and their relatives. A questionnaire form including information and behavior about colonoscopic screening for CRCs of patients and their first-degree relatives (FDRs) was prepared. A total of 406 CRC patients were enrolled into the study, with 1534 FDRs (siblings n: 1381 and parents n: 153) . Positive family history for CRC was found in 12% of the study population. Previous SC was performed in 11% of patients with CRC. Mean age of the patients whose FDRs underwent SC was lower than the patients whose FDRs did not (52 vs 57 years; peducational level and income had SC more frequently. When screening for CRC is planned, elderly subjects, those with family history for CRC, and those with low educational and lower income should be given especial attention in order that they be convinced to undergo screening for CRC.

  15. Comparison between different colon cleansing products for screening colonoscopy. A noninferiority trial in population-based screening programs in Italy.

    Science.gov (United States)

    Zorzi, Manuel; Valiante, Flavio; Germanà, Bastianello; Baldassarre, Gianluca; Coria, Bartolomea; Rinaldi, Michela; Heras Salvat, Helena; Carta, Alessandra; Bortoluzzi, Francesco; Cervellin, Erica; Polo, Maria Luisa; Bulighin, Gianmarco; Azzurro, Maurizio; Di Piramo, Daniele; Turrin, Anna; Monica, Fabio

    2016-03-01

    The high volume and poor palatability of 4 L of polyethylene glycol (PEG)-based bowel cleansing preparation required before a colonoscopy represent a major obstacle for patients. The aim of this study was to compare two low volume PEG-based preparations with standard 4 L PEG in individuals with a positive fecal immunochemical test (FIT) within organized screening programs in Italy. A total of 3660 patients with a positive FIT result were randomized to receive, in a split-dose regimen, 4 L PEG or 2 L PEG plus ascorbate (PEG-A) or 2 L PEG with citrate and simethicone plus bisacodyl (PEG-CS). The noninferiority of the low volume preparations vs. 4 L PEG was tested through the difference in proportions of adequate cleansing. A total of 2802 patients were included in the study. Adequate bowel cleansing was achieved in 868 of 926 cases (93.7 %) in the 4 L PEG group, in 872 out of 911 cases in the PEG-A group (95.7 %, difference in proportions  + 1.9 %, 95 % confidence interval [CI]  - 0.1 to 3.9), and in 862 out of 921 cases in the PEG-CS group (93.6 %, difference in proportions  - 0.2 %, 95 %CI  - 2.4 to 2.0). Bowel cleansing was adequate in 95.5 % of cases when the preparation-to-colonoscopy interval was between 120 and 239 minutes, whereas it dropped to 83.3 % with longer intervals. Better cleansing was observed in patients with regular bowel movements (95.6 %) compared with those with diarrhea (92.4 %) or constipation (90.8 %). Low volume PEG-based preparations administered in a split-dose regimen guarantee noninferior bowel cleansing compared with 4 L PEG. Constipated patients require a personalized preparation. EudraCT 2012 - 003958 - 82. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Variation in use of surveillance colonoscopy among colorectal cancer survivors in the United States

    Directory of Open Access Journals (Sweden)

    Salz Talya

    2010-09-01

    Full Text Available Abstract Background Clinical practice guidelines recommend colonoscopies at regular intervals for colorectal cancer (CRC survivors. Using data from a large, multi-regional, population-based cohort, we describe the rate of surveillance colonoscopy and its association with geographic, sociodemographic, clinical, and health services characteristics. Methods We studied CRC survivors enrolled in the Cancer Care Outcomes Research and Surveillance (CanCORS study. Eligible survivors were diagnosed between 2003 and 2005, had curative surgery for CRC, and were alive without recurrences 14 months after surgery with curative intent. Data came from patient interviews and medical record abstraction. We used a multivariate logit model to identify predictors of colonoscopy use. Results Despite guidelines recommending surveillance, only 49% of the 1423 eligible survivors received a colonoscopy within 14 months after surgery. We observed large regional differences (38% to 57% across regions. Survivors who received screening colonoscopy were more likely to: have colon cancer than rectal cancer (OR = 1.41, 95% CI: 1.05-1.90; have visited a primary care physician (OR = 1.44, 95% CI: 1.14-1.82; and received adjuvant chemotherapy (OR = 1.75, 95% CI: 1.27-2.41. Compared to survivors with no comorbidities, survivors with moderate or severe comorbidities were less likely to receive surveillance colonoscopy (OR = 0.69, 95% CI: 0.49-0.98 and OR = 0.44, 95% CI: 0.29-0.66, respectively. Conclusions Despite guidelines, more than half of CRC survivors did not receive surveillance colonoscopy within 14 months of surgery, with substantial variation by site of care. The association of primary care visits and adjuvant chemotherapy use suggests that access to care following surgery affects cancer surveillance.

  17. CT colonoscopy: sensibility in 2D/4D CT colonoscopy versus virtual endoscopy. Correlation to conventional colonoscopy

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Capunay, Carlos; Sanchez, Flavio; Castiglioni, Roberto; Carrascosa, Jorge

    2001-01-01

    Colorectal carcinoma is the second leading cause of death from malignant tumors. Most large bowel malignancies arise from pre-existing adenomas. In individual older than 50 years the prevalence of polyps and cancer increases. Therefore screening is recommended for average risk individuals in this group. Recently a new technique called 'Virtual Colonoscopy' has appeared. The purpose of this study was to compare the diagnosis accuracy of two dimensional CT Colonoscopy (2D CTC) and Virtual Colonoscopy (VC) individually with Conventional Colonoscopy (CC) and to determine improvement of the Sensitivity (S) and Specificity (E) combining both types of evaluation. Ninety patients were studied (47 women and 43 men). CT studies were obtained on a helical CT scanner. The lesions were studied in supine and prone position. All patients had CC done within 10 hours before CTC. The lesions were divided in 3 groups: 1) 9 mm. Each group was divided into 3 subgroups: a) findings in 2D; b) findings in VC; and c) findings combined. Ninety-two lesions were identified on CC and 101 on CTC. There were 9 false positive in all groups. The statistical analysis showed a high S and E in both 2D and VC. The combination of both methods does not increase significantly the diagnosis of CTC but the S reached 100% because the false negative rate was reduced to 0. (author)

  18. Quality of colonoscopy in an organised colorectal cancer screening programme with immunochemical faecal occult blood test: the EQuIPE study (Evaluating Quality Indicators of the Performance of Endoscopy).

    Science.gov (United States)

    Zorzi, Manuel; Senore, Carlo; Da Re, Filippo; Barca, Alessandra; Bonelli, Luigina Ada; Cannizzaro, Renato; Fasoli, Renato; Di Furia, Lucia; Di Giulio, Emilio; Mantellini, Paola; Naldoni, Carlo; Sassatelli, Romano; Rex, Douglas; Hassan, Cesare; Zappa, Marco

    2015-09-01

    To assess variation in the main colonoscopy quality indicators in organised colorectal cancer (CRC) screening programmes based on faecal immunochemical test (FIT). Data from a case-series of colonoscopies of FIT-positive subjects were provided by 44 Italian CRC screening programmes. Data on screening history, endoscopic procedure and histology results, and additional information on the endoscopy centre and the endoscopists were collected. The adenoma detection rate (ADR) and caecal intubation rate (CIR) were assessed for the whole population and the individual endoscopists. To explore variation in the quality indicators, multilevel analyses were performed according to patient/centre/endoscopist characteristics. We analysed 75 569 (mean age: 61.3 years; men: 57%) colonoscopies for positive FIT performed by 479 endoscopists in 79 centres. ADR ranged from 13.5% to 75% among endoscopists (mean: 44.8%). ADR was associated with gastroenterology specialty (OR: 0.87 for others, 95% CI 0.76 to 0.96) and, at the endoscopy centre level, with the routine use of sedation (OR: 0.80 if occasional (600 colonoscopies; 95% CI 1.11 to 2.04) and, at the endoscopy centre level, screening-dedicated sessions (OR: 2.18; 95% CI 1.24 to 3.83) and higher rates of sedation (OR: 0.47 if occasional; 95% CI 0.24 to 0.92). The quality of colonoscopy was affected by patient-related, endoscopist-related and centre-related characteristics. Policies addressing organisational issues should improve the quality of colonoscopy in our programme and similar programmes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Value of Virtual Colonoscopy with 64 Row CT in Evaluation of Colorectal Cancer

    International Nuclear Information System (INIS)

    Zaleska-Dorobisz, Urszula; Łasecki, Mateusz; Nienartowicz, Ewa; Pelak, Joanna; Słonina, Joanna; Olchowy, Cyprian; Ścieżka, Marek; Sąsiadek, Marek

    2014-01-01

    Virtual colonoscopy (VC) enables three-dimensional view of walls and internal lumen of the colon as a result of reconstruction of multislice CT images. The role of VC in diagnosis of the colon abnormalities systematically increases, and in many medical centers all over the world is carried out as a screening test of patients with high risk of colorectal cancer. We analyzed results of virtual colonoscopy of 360 patients with clinical suspicion of colorectal cancer. Sensitivity and specificity of CT colonoscopy for detection of colon cancers and polyps were assessed. Results of our research have shown high diagnostic efficiency of CT colonoscopy in detection of focal lesions in large intestine of 10 mm or more diameter. Sensitivity was 85.7%, specificity 89.2%. Virtual colonoscopy is noninvasive and well tolerated by patients imaging method, which permits for early detection of the large intestine lesions with specificity and sensitivity similar to classical colonoscopy in screening exams in patients suspected for colorectal cancer. Good preparation of the patients for the examination is very important for proper diagnosis and interpretation of this imaginge procedure

  20. Results of a Community-based, Randomized Study Comparing a Clear Liquid Diet With a Low-residue Diet Using a Magnesium Citrate Preparation for Screening and Surveillance Colonoscopies.

    Science.gov (United States)

    Thukral, Chandrashekhar; Tewani, Sumeet K; Lake, Adam J; Shiels, Aaron J; Geissler, Kathy; Popejoy, Sara; Stafford, Megan; Vicari, Joseph J

    2017-11-03

    Current bowel preparations for colonoscopy include a clear liquid diet (CLD) along with consumption of a laxative. This dietary restriction along with large volume bowel preparations are barriers to compliance and willingness among patients in scheduling screening examinations. The aim of our study was to compare the efficacy and tolerability of a low-volume split dose magnesium citrate bowel preparation in patients on a low-residue diet (LRD) with those on a CLD. In this single center, single blinded, randomized controlled trial, patients scheduled for outpatient colonoscopies were assigned to either a CLD or a LRD 1 day before the examination. Both groups received a split dose magnesium citrate preparation. The quality of the preparation was rated using the Boston Bowel Preparation Scale (BBPS). Patient satisfaction and side effects were evaluated using a questionnaire. We were unable to detect a significant difference in the BBPS scores between the LRD and CLD groups (P=0.581). A significantly higher percentage of patients in the LRD group rated the diet as easy compared with the CLD group (PCLD group (PCLD in patients using a magnesium citrate bowel preparation for screening and surveillance colonoscopies. Patient satisfaction scores were higher with a LRD compared with a CLD. We believe the LRD should be the recommended diet in patients using a standard bowel preparation for screening and surveillance colonoscopy.

  1. Optimism and barriers to colonoscopy in low-income Latinos at average risk for colorectal cancer.

    Science.gov (United States)

    Efuni, Elizaveta; DuHamel, Katherine N; Winkel, Gary; Starr, Tatiana; Jandorf, Lina

    2015-09-01

    Colorectal cancer (CRC) screening continues to be underused, particularly by Latinos. CRC and colonoscopy fear, worry, and fatalism have been identified as screening barriers in Latinos. The study purpose was to examine the relationship of optimism, fatalism, worry, and fear in the context of Latinos referred for CRC screening. Our sample included 251 Latinos between the ages of 50 and 83 years who had no personal or immediate family history of CRC, no personal history of gastrointestinal disorder, no colonoscopy in the past 5 years, and received a referral for a colonoscopy. Face-to-face interviews were performed, and data were analyzed using regression models. Greater optimism (β = -1.72, p optimism (β = -0.09, p < 0.05), higher fatalism (β = 0.28, p < 0.01), and female gender (β = 0.9, p < 0.05) were associated with greater worry. Interventions that address fatalism and promote optimistic beliefs may reduce worry among Latinos referred for colonoscopy. Interventions that alleviate colonoscopy fear because of family history of cancer particularly among Latino women may help improve distress about CRC screening. Copyright © 2014 John Wiley & Sons, Ltd.

  2. Comparison of Colonoscopy Quality Measures Across Various Practice Settings and the Impact of Performance Scorecards.

    Science.gov (United States)

    Inra, Jennifer A; Nayor, Jennifer; Rosenblatt, Margery; Mutinga, Muthoka; Reddy, Sarathchandra I; Syngal, Sapna; Kastrinos, Fay

    2017-04-01

    Quality performance measures for screening colonoscopy vary among endoscopists. The impact of practice setting is unknown. We aimed to (1) compare screening colonoscopy performance measures among three different US practice settings; (2) evaluate factors associated with adenoma detection; and (3) assess a scorecard intervention on performance metrics. This multi-center prospective study compared patient, endoscopist, and colonoscopy characteristics performed at a tertiary care hospital (TCH), community-based hospital (CBH), and private practice group (PPG). Withdrawal times (WT), cecal intubation, and adenoma detection rates (ADR) were compared by site at baseline and 12 weeks following scorecard distribution. Generalized linear mixed models identified factors associated with adenoma detection. Twenty-eight endoscopists performed colonoscopies on 1987 asymptomatic, average-risk individuals ≥50 years. Endoscopist and patient characteristics were similar across sites. The PPG screened more men (TCH: 42.8%, CBH: 45.0%, PPG: 54.2%; p scorecard distribution. Adenoma detection was associated with increasing patient age, male gender, WT, adequate preparation, but not practice setting. Each practice performed high-quality screening colonoscopy. Scorecards did not improve performance metrics. Preparation quality varies among practice settings and can be modified to improve adenoma detection.

  3. Acceptance of Colonoscopy Requires more than Test Tolerance

    Directory of Open Access Journals (Sweden)

    Amanda Condon

    2008-01-01

    Full Text Available BACKGROUND: Colon cancer screening, including colonoscopy, lags behind other forms of cancer screening for participation rates. The intrinsic nature of the endoscopic procedure may be an important barrier that limits patients from finding this test acceptable and affects willingness to undergo screening. With colon cancer screening programs emerging in Canada, test characteristics and their impact on acceptance warrant consideration.

  4. Quality audit of colonoscopy reports amongst patients screened or surveilled for colorectal neoplasia.

    Science.gov (United States)

    Beaulieu, Daphnée; Barkun, Alan; Martel, Myriam

    2012-07-21

    To complete a quality audit using recently published criteria from the Quality Assurance Task Group of the National Colorectal Cancer Roundtable. Consecutive colonoscopy reports of patients at average/high risk screening, or with a prior colorectal neoplasia (CRN) by endoscopists who perform 11 000 procedures yearly, using a commercial computerized endoscopic report generator. A separate institutional database providing pathological results. Required documentation included patient demographics, history, procedure indications, technical descriptions, colonoscopy findings, interventions, unplanned events, follow-up plans, and pathology results. Reports abstraction employed a standardized glossary with 10% independent data validation. Sample size calculations determined the number of reports needed. Two hundreds and fifty patients (63.2 ± 10.5 years, female: 42.8%, average risk: 38.5%, personal/family history of CRN: 43.3%/20.2%) were scoped in June 2009 by 8 gastroenterologists and 3 surgeons (mean practice: 17.1 ± 8.5 years). Procedural indication and informed consent were always documented. 14% provided a previous colonoscopy date (past polyp removal information in 25%, but insufficient in most to determine surveillance intervals appropriateness). Most procedural indicators were recorded (exam date: 98.4%, medications: 99.2%, difficulty level: 98.8%, prep quality: 99.6%). All reports noted extent of visualization (cecum: 94.4%, with landmarks noted in 78.8% - photodocumentation: 67.2%). No procedural times were recorded. One hundred and eleven had polyps (44.4%) with anatomic location noted in 99.1%, size in 65.8%, morphology in 62.2%; removal was by cold biopsy in 25.2% (cold snare: 18%, snare cautery: 31.5%, unrecorded: 20.7%), 84.7% were retrieved. Adenomas were noted in 24.8% (advanced adenomas: 7.6%, cancer: 0.4%) in this population with varying previous colonic investigations. This audit reveals lacking reported items, justifying additional research to

  5. Charity colonoscopy event to commemorate the 185th anniversary of Singapore General Hospital.

    Science.gov (United States)

    Ng, Kheng Hong; Lim, Jit Fong; Ho, Kok Sun; Ooi, Boon Swee; Tang, Choong Leong; Eu, Kong Weng

    2008-03-01

    Colorectal cancer is now the cancer with the highest incidence in Singapore. However, the overall mortality rate is still about 50% because the majority of the patients present at a late stage of disease. A charity event of screening colonoscopy was offered to the public in conjunction with the 185th anniversary of Singapore General Hospital. The aim of this event was to raise awareness about early detection of colorectal cancer and the safety of colonoscopy. We conducted a one-off free screening event for colorectal cancer using colonoscopy. Four hundred and ninety individuals responded to a multimedia advertisement for the event. Of these, 220 individuals were selected for the screening based on National Guidelines for colorectal cancer screening and financial status. One hundred and fifty-two individuals turned up for the colonoscopy. The median age was 55 years (range, 22 to 82), with 84 males. Significant pathology was found in 33% of the individuals (n = 51). Colorectal polyps were detected in 34 individuals (22%). A total of 45 polyps were removed, with 20 hyperplastic polyps and 25 adenomas. Eight out of 25 adenomas were located proximal to the splenic flexure. Rectal cancer was diagnosed in 1 individual (0.6%). One individual had a large dysplastic rectosigmoid ulcer and refused further intervention. There were no significant complications from any of the colonoscopies. Colonoscopy is an invaluable screening modality as it has a high pick-up rate for colorectal polyp and cancer in an asymptomatic population. It is also proven to be safe in our study. It has the added advantage over flexible sigmoidoscopy of detecting a significant number of proximal lesions. Also, therapeutic polypectomy can be performed in the same setting.

  6. Is Travel Time to Colonoscopy Associated With Late-Stage Colorectal Cancer Among Medicare Beneficiaries in Iowa?

    Science.gov (United States)

    Charlton, Mary E; Matthews, Kevin A; Gaglioti, Anne; Bay, Camden; McDowell, Bradley D; Ward, Marcia M; Levy, Barcey T

    2016-09-01

    Colorectal cancer (CRC) screening has been shown to decrease the incidence of late-stage colorectal cancer, yet a substantial proportion of Americans do not receive screening. Those in rural areas may face barriers to colonoscopy services based on travel time, and previous studies have demonstrated lower screening among rural residents. Our purpose was to assess factors associated with late-stage CRC, and specifically to determine if longer travel time to colonoscopy was associated with late-stage CRC among an insured population in Iowa. SEER-Medicare data were used to identify individuals ages 65 to 84 years old diagnosed with CRC in Iowa from 2002 to 2009. The distance between the centroid of the ZIP code of residence and the ZIP code of colonoscopy was computed for each individual who had continuous Medicare fee-for-service coverage for a 3- to 4-month period prior to diagnosis, and a professional claim for colonoscopy within that time frame. Demographic characteristics and travel times were compared between those diagnosed with early- versus late-stage CRC. Also, demographic differences between those who had colonoscopy claims identified within 3-4 months prior to diagnosis (81%) were compared to patients with no colonoscopy claims identified (19%). A total of 5,792 subjects met inclusion criteria; 31% were diagnosed with early-stage versus 69% with late-stage CRC. Those divorced or widowed (vs married) were more likely to be diagnosed with late-stage CRC (OR: 1.20, 95% CI: 1.06-1.37). Travel time was not associated with diagnosis of late-stage CRC. Among a Medicare-insured population, there was no relationship between travel time to colonoscopy and disease stage at diagnosis. It is likely that factors other than distance to colonoscopy present more pertinent barriers to screening in this insured population. Additional research should be done to determine reasons for nonadherence to screening among those with access to CRC screening services, given that over

  7. Observational methods to assess the effectiveness of screening colonoscopy in reducing right colon cancer mortality risk: SCOLAR.

    Science.gov (United States)

    Goodman, Michael; Fletcher, Robert H; Doria-Rose, V Paul; Jensen, Christopher D; Zebrowski, Alexis M; Becerra, Tracy A; Quinn, Virginia P; Zauber, Ann G; Corley, Douglas A; Doubeni, Chyke A

    2015-11-01

    Screening colonoscopy's effectiveness in reducing risk of death from right colon cancers remains unclear. Methodological challenges of existing observational studies addressing this issue motivated the design of 'Effectiveness of Screening for Colorectal Cancer in Average-Risk Adults (SCOLAR)'. SCOLAR is a nested case-control study based on two large integrated health systems. This affords access to a large, well-defined historical cohort linked to integrated data on cancer outcomes, patient eligibility, test indications and important confounders. We found electronic data adequate for excluding ineligible patients (except family history), but not the detailed information needed for test indication assignment. The lessons of SCOLAR's design and implementation may be useful for future studies seeking to evaluate the effectiveness of screening tests in community settings.

  8. Relating Stool Microbial Metabolite Levels, Inflammatory Markers and Dietary Behaviors to Screening Colonoscopy Findings in a Racially/Ethnically Diverse Patient Population

    Directory of Open Access Journals (Sweden)

    Kristina M. Bridges

    2018-02-01

    Full Text Available Colorectal cancer (CRC is the third leading cause of cancer death for both men and women in the United States, yet it is treatable and preventable. African Americans have higher incidence of CRC than other racial/ethnic groups, however, it is unclear whether this disparity is primarily due to environmental or biological factors. Short chain fatty acids (SCFAs are metabolites produced by bacteria in the colon and are known to be inversely related to CRC progression. The aim of this study is to investigate how stool SCFA levels, markers of inflammation in stool and dietary intake relate to colonoscopy findings in a diverse patient population. Stool samples from forty-eight participants were analyzed for SCFA levels and inflammatory markers (lysozyme, secretory IgA, lactoferrin. Additionally, participants completed the National Cancer Institute’s Diet History Questionnaire II (DHQ II to report dietary intake over the past year. Subsequently, the majority of participants underwent screening colonoscopy. Our results showed that African Americans had higher total levels of SCFAs in stool than other racial/ethnic groups, significantly lower intake of non-starchy vegetables and similar inflammatory marker expression and colonoscopy outcomes, compared to others. This work is an initial exploration into the biological and clinical factors that may ultimately inform personalized screening approaches and clinical decision-making to improve colorectal cancer disparities for African Americans.

  9. Relating Stool Microbial Metabolite Levels, Inflammatory Markers and Dietary Behaviors to Screening Colonoscopy Findings in a Racially/Ethnically Diverse Patient Population

    Science.gov (United States)

    Bridges, Kristina M.; Diaz, Francisco J.; Wang, Zhiwen; Ahmed, Ishfaq; Sullivan, Debra K.; Umar, Shahid; Buckles, Daniel C.; Greiner, K. Allen; Hester, Christina M.

    2018-01-01

    Colorectal cancer (CRC) is the third leading cause of cancer death for both men and women in the United States, yet it is treatable and preventable. African Americans have higher incidence of CRC than other racial/ethnic groups, however, it is unclear whether this disparity is primarily due to environmental or biological factors. Short chain fatty acids (SCFAs) are metabolites produced by bacteria in the colon and are known to be inversely related to CRC progression. The aim of this study is to investigate how stool SCFA levels, markers of inflammation in stool and dietary intake relate to colonoscopy findings in a diverse patient population. Stool samples from forty-eight participants were analyzed for SCFA levels and inflammatory markers (lysozyme, secretory IgA, lactoferrin). Additionally, participants completed the National Cancer Institute’s Diet History Questionnaire II (DHQ II) to report dietary intake over the past year. Subsequently, the majority of participants underwent screening colonoscopy. Our results showed that African Americans had higher total levels of SCFAs in stool than other racial/ethnic groups, significantly lower intake of non-starchy vegetables and similar inflammatory marker expression and colonoscopy outcomes, compared to others. This work is an initial exploration into the biological and clinical factors that may ultimately inform personalized screening approaches and clinical decision-making to improve colorectal cancer disparities for African Americans. PMID:29495356

  10. Colonoscopy resource availability and colonoscopy utilization in Ontario, Canada

    Directory of Open Access Journals (Sweden)

    Colleen Webber

    2017-04-01

    The availability of colonoscopy resources improved in Ontario between 2007 and 2013. However, the geographic variation in resource availability and findings that higher colonoscopy resource availability is associated with higher colonoscopy utilization suggest that certain areas of the province may be under-resourced. These areas may be appropriate targets for efforts to improve colonoscopy capacity in Ontario.

  11. Preliminary development of the Active Colonoscopy Training Model

    Directory of Open Access Journals (Sweden)

    Choi J

    2011-06-01

    Full Text Available JungHun Choi1, Kale Ravindra1, Randolph Robert1, David Drozek21Mechanical Engineering, Ohio University, Athens, OH, USA; 2College of Osteopathic Medicine, Ohio University, Athens, OH, USAAbstract: Formal colonoscopy training requires a significant amount of time and effort. In particular, it requires actual patients for a realistic learning experience. The quality of colonoscopy training varies, and includes didactic courses and procedures proctored by skilled surgeons. A colonoscopy training model is occasionally used as part of the training method, but the effects are minute due to both the simple and tedious training procedures. To enhance the educational effect of the colonoscopy training model, the Active Colonoscopy Training Model (ACTM has been developed. ACTM is an interactive colonoscopy training device which can create the environment of a real colonoscopy procedure as closely as possible. It comprises a configurable rubber colon, a human torso, sensors, a display, and the control part. The ACTM provides audio and visual interaction to the trainee by monitoring important factors, such as forces caused by the distal tip and the shaft of the colonoscope and the pressure to open up the lumen and the localization of the distal tip. On the computer screen, the trainee can easily monitor the status of the colonoscopy, which includes the localization of the distal tip, maximum forces, pressure inside the colon, and surgery time. The forces between the rubber colon and the constraints inside the ACTM are measured and the real time display shows the results to the trainee. The pressure sensors will check the pressure at different parts of the colon. The real-time localized distal tip gives the colonoscopy trainee easier and more confident operation without introducing an additional device in the colonoscope. With the current need for colonoscopists and physicians, the ACTM can play an essential role resolving the problems of the current

  12. Leadership training to improve adenoma detection rate in screening colonoscopy: A randomised trial

    NARCIS (Netherlands)

    M.F. Kaminski (Michal); J. Anderson (John); R.M. Valori (Roland ); E. Kraszewska (Ewa); M. Rupinski (Maciej); J. Pachlewski (Jacek); E. Wronska (Ewa); M. Bretthauer (Michael); S. Thomas-Gibson (Siwan); E.J. Kuipers (Ernst); J. Regula (J.)

    2016-01-01

    textabstractObjective Suboptimal adenoma detection rate (ADR) at colonoscopy is associated with increased risk of interval colorectal cancer. It is uncertain how ADR might be improved. We compared the effect of leadership training versus feedback only on colonoscopy quality in a countrywide

  13. Virtual Colonoscopy Screening With Ultra Low-Dose CT and Less-Stressful Bowel Preparation: A Computer Simulation Study

    Science.gov (United States)

    Wang, Jing; Wang, Su; Li, Lihong; Fan, Yi; Lu, Hongbing; Liang, Zhengrong

    2008-10-01

    Computed tomography colonography (CTC) or CT-based virtual colonoscopy (VC) is an emerging tool for detection of colonic polyps. Compared to the conventional fiber-optic colonoscopy, VC has demonstrated the potential to become a mass screening modality in terms of safety, cost, and patient compliance. However, current CTC delivers excessive X-ray radiation to the patient during data acquisition. The radiation is a major concern for screening application of CTC. In this work, we performed a simulation study to demonstrate a possible ultra low-dose CT technique for VC. The ultra low-dose abdominal CT images were simulated by adding noise to the sinograms of the patient CTC images acquired with normal dose scans at 100 mA s levels. The simulated noisy sinogram or projection data were first processed by a Karhunen-Loeve domain penalized weighted least-squares (KL-PWLS) restoration method and then reconstructed by a filtered backprojection algorithm for the ultra low-dose CT images. The patient-specific virtual colon lumen was constructed and navigated by a VC system after electronic colon cleansing of the orally-tagged residue stool and fluid. By the KL-PWLS noise reduction, the colon lumen can successfully be constructed and the colonic polyp can be detected in an ultra low-dose level below 50 mA s. Polyp detection can be found more easily by the KL-PWLS noise reduction compared to the results using the conventional noise filters, such as Hanning filter. These promising results indicate the feasibility of an ultra low-dose CTC pipeline for colon screening with less-stressful bowel preparation by fecal tagging with oral contrast.

  14. Automatic polyp detection in colonoscopy videos

    Science.gov (United States)

    Yuan, Zijie; IzadyYazdanabadi, Mohammadhassan; Mokkapati, Divya; Panvalkar, Rujuta; Shin, Jae Y.; Tajbakhsh, Nima; Gurudu, Suryakanth; Liang, Jianming

    2017-02-01

    Colon cancer is the second cancer killer in the US [1]. Colonoscopy is the primary method for screening and prevention of colon cancer, but during colonoscopy, a significant number (25% [2]) of polyps (precancerous abnormal growths inside of the colon) are missed; therefore, the goal of our research is to reduce the polyp miss-rate of colonoscopy. This paper presents a method to detect polyp automatically in a colonoscopy video. Our system has two stages: Candidate generation and candidate classification. In candidate generation (stage 1), we chose 3,463 frames (including 1,718 with-polyp frames) from real-time colonoscopy video database. We first applied processing procedures, namely intensity adjustment, edge detection and morphology operations, as pre-preparation. We extracted each connected component (edge contour) as one candidate patch from the pre-processed image. With the help of ground truth (GT) images, 2 constraints were implemented on each candidate patch, dividing and saving them into polyp group and non-polyp group. In candidate classification (stage 2), we trained and tested convolutional neural networks (CNNs) with AlexNet architecture [3] to classify each candidate into with-polyp or non-polyp class. Each with-polyp patch was processed by rotation, translation and scaling for invariant to get a much robust CNNs system. We applied leave-2-patients-out cross-validation on this model (4 of 6 cases were chosen as training set and the rest 2 were as testing set). The system accuracy and sensitivity are 91.47% and 91.76%, respectively.

  15. Do patients undergo prostate examination while having a colonoscopy?

    Science.gov (United States)

    Hammett, Tess; Hookey, Lawrence C; Kawakami, Jun

    2009-01-01

    To determine the rate at which physicians report performing a digital rectal examination and comment on the prostate gland before performing colonoscopy in men 50 to 70 years of age. A retrospective chart review of all men 50 to 70 years of age who had a colonoscopy in Kingston, Ontario, in 2005 was completed. It was noted whether each physician described performing a digital rectal examination before the colonoscopy, and if so, whether he or she commented on the prostate. In 2005, 846 eligible colonoscopies were performed by 17 physicians in Kingston, Ontario. In 29.2% of cases, the physician made no comment about having performed a digital rectal examination; in 55.8% of cases, the physician commented on having completed a digital rectal examination but said nothing about the prostate; and in 15.0% of cases, the physician made a comment regarding the prostate. No physician consistently commented on the prostate for all patients, and in no circumstances was direct referral to another physician or follow-up suggested. A colonoscopy presents an ideal opportunity for physicians to use a digital rectal examination to assess for prostate cancer. Physicians performing colonoscopies in men 50 to 70 years of age should pay special attention to the prostate while performing a digital rectal examination before colonoscopy. This novel concept may help maximize resources for cancer screening and could potentially increase the detection rate of clinically palpable prostate cancer.

  16. Diagnostic value of CT-colonography as compared to colonoscopy in an asymptomatic screening population: a meta-analysis

    International Nuclear Information System (INIS)

    Haan, Margriet C. de; Gelder, Rogier E. van; Bipat, Shandra; Stoker, Jaap; Graser, Anno

    2011-01-01

    Previous meta-analyses on CT-colonography included both average and high risk individuals, which may overestimate the diagnostic value in screening. A meta-analysis was performed to obtain the value of CT-colonography for screening. A search was performed using PubMed, Embase and Cochrane. Article selection and critical appraisal was done by two reviewers. Inclusion criteria: prospective, randomized trials or cohort studies comparing CT-colonography with colonoscopy (≥50 participants), ≥95% average risk participants ≥50 years. Study characteristics and 2 x 2 contingency Tables were recorded. Sensitivity and specificity estimates were calculated per patient and per polyp (≥6 mm, ≥10 mm), using univariate and bivariate analyses. Five of 1,021 studies identified were included, including 4,086 participants ( 2 -values showed substantial heterogeneity, especially for 6-9 mm polyps and adenomas: 68.1% vs. 78.6% (sensitivity per patient). Estimated sensitivities for patients with polyps or adenomas ≥ 6 mm were 75.9% and 82.9%, corresponding specificities 94.6% and 91.4%. Estimated sensitivities for patients with polyps or adenomas ≥ 10 mm were 83.3% and 87.9%, corresponding specificities 98.7% and 97.6%. Estimated sensitivities per polyp for advanced adenomas ≥ 6 mm and ≥ 10 mm were 83.9% and 83.8%. Compared to colonoscopy, CT-colonography has a high sensitivity for adenomas ≥ 10 mm. For (advanced) adenomas ≥ 6 mm sensitivity is somewhat lower. (orig.)

  17. Intrinsic motivation factors based on the self-determinant theory for regular breast cancer screening.

    Science.gov (United States)

    Jung, Su Mi; Jo, Heui-Sug

    2014-01-01

    The purpose of this study was to identify factors of intrinsic motivation that affect regular breast cancer screening and contribute to development of a program for strategies to improve effective breast cancer screening. Subjects were residing in South Korea Gangwon-Province and were female over 40 and under 69 years of age. For the investigation, the Intrinsic Motivation Inventory (IMI) was modified to the situation of cancer screening and was used to survey 905 inhabitants. Multinominal logistic regression analyses were conducted for regular breast cancer screening (RS), one-time breast cancer screening (OS) and non-breast cancer screening (NS). For statistical analysis, IBM SPSS 20.0 was utilized. The determinant factors between RS and NS were "perceived effort and choice" and "stress and strain" - internal motivations related to regular breast cancer screening. Also, determinant factors between RS and OS are "age" and "perceived effort and choice" for internal motivation related to cancer screening. To increase regular screening, strategies that address individual perceived effort and choice are recommended.

  18. Audit of colonoscopy practice in Lagos University Teaching Hospital

    Directory of Open Access Journals (Sweden)

    Adedapo Osinowo

    2016-01-01

    Full Text Available Introduction: Recent procurement of new endoscopies and accessories led to the reactivation of diagnostic and therapeutic colonoscopy services at our center. A preliminary audit is deemed necessary after a 2-year period of open access colonoscopy. Objective: To assess the pattern of indications, diagnostic yield, and selected key performance indicators in the practice of colonoscopy at our tertiary hospital. Patients and Methods: The endoscopy reports of all patients that underwent colonoscopy from January 2012 to April 2014 were reviewed. The demographic data, indications, and endoscopic findings were recorded. Information on cecal intubation, colonoscopy withdrawal time, polyp detection, adverse events, and bowel preparation quality were also extracted and analyzed. Results: Colonoscopy was performed in 149 patients. They were 81 males and 68 females, aged between 18 and 101 years with a mean of 46.9 ± 22.7 years. 126 (84.5% patients had a colonoscopy for symptomatic conditions while 5 (4% were for screening. Bowel preparation was assessed to be excellent in 81 (54.4%, adequate in 42 (28.2%, and inadequate in 26 (17.4% patients, respectively. The cecal intubation rate (CIR was 80.2%, polyp detection rate 7.4%, average colonoscopy withdrawal time was 6 min 53 s, overall diagnostic yield 55.9% and there were no adverse events. Tumors were seen in 19 patients (10.1%; 13 were located in the rectum, three in the sigmoid and three in the descending colon. Conclusion: The audit revealed that our CIR could be improved by a more effective bowel preparation, increased expertise, and procedure volume of endoscopists. Tumors of the colorectum were detected in 10.1% of patients.

  19. Colonoscopy: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish Virtual colonoscopy (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Colonoscopy updates by ... Colonoscopy Colonoscopy discharge Sigmoidoscopy Virtual colonoscopy Related Health Topics Colonic Diseases Colonic Polyps Colorectal Cancer National Institutes ...

  20. Virtual colonoscopy

    Science.gov (United States)

    Colonoscopy - virtual; CT colonography; Computed tomographic colonography; Colography - virtual ... Differences between virtual and conventional colonoscopy include: VC can view the colon from many different angles. This is not as easy ...

  1. Developing a tool to preserve eye contact with patients undergoing colonoscopy for pain monitoring

    Directory of Open Access Journals (Sweden)

    Niv Y

    2012-08-01

    Full Text Available Yaron Niv, Yossi TalDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, IsraelAbstract: Colonoscopy has become the leading procedure for early detection and prevention of colorectal cancer. Patients’ experience of colonic endoscopic procedures is scarcely reported, even though it is considered a major factor in colorectal cancer screening participation. Pain due to air inflation or stretching the colon with an endoscope is not rare during examination and may be the main obstacle to cooperation and participation in a screening program. We propose a four-stage study for developing a tool dedicated to pain monitoring during colonoscopy, as follows: (1 comparison of patient, nurse, and endoscopist questionnaire responses about patient pain and technical details of the procedure using the PAINAD tool during colonoscopy; (2 observation of the correlation between patients’ facial expressions and other parameters (using the short PAINAD; (3 development of a device for continuous monitoring of the patient’s facial expression during the procedure; (4 assessment of the usability of such a tool and its contribution to the outcomes of colonoscopy procedures. Early intervention by the staff performing the procedure, in reaction to alerts encoded by this tool, may prevent adverse events during the procedure.Keywords: pain scoring, colonoscopy, pain monitoring, facial expression

  2. Changes in screening behaviors and attitudes toward screening from pre-test genetic counseling to post-disclosure in Lynch syndrome families

    Science.gov (United States)

    Burton-Chase, Allison M.; Hovick, Shelly R.; Peterson, Susan K.; Marani, Salma K.; Vernon, Sally W.; Amos, Christopher I.; Frazier, Marsha L.; Lynch, Patrick M.; Gritz, Ellen R.

    2013-01-01

    Purpose This study examined colonoscopy adherence and attitudes towards colorectal cancer (CRC) screening in individuals who underwent Lynch syndrome genetic counseling and testing. Methods We evaluated changes in colonoscopy adherence and CRC screening attitudes in 78 cancer-unaffected relatives of Lynch syndrome mutation carriers before pre-test genetic counseling (baseline) and at 6 and 12 months post-disclosure of test results (52 mutation-negative, 26 mutation-positive). Results While both groups were similar at baseline, at 12 months post-disclosure, a greater number of mutation-positive individuals had had a colonoscopy compared with mutation-negative individuals. From baseline to 12 months post-disclosure, the mutation-positive group demonstrated an increase in mean scores on measures of colonoscopy commitment, self-efficacy, and perceived benefits of CRC screening, and a decrease in mean scores for perceived barriers to CRC screening. Mean scores on colonoscopy commitment decreased from baseline to 6 months in the mutation-negative group. Conclusion Adherence to risk-appropriate guidelines for CRC surveillance improved after genetic counseling and testing for Lynch syndrome. Mutation-positive individuals reported increasingly positive attitudes toward CRC screening after receiving genetic test results, potentially reinforcing longer term colonoscopy adherence. PMID:23414081

  3. Risk Factors for Hemorrhoids on Screening Colonoscopy.

    Directory of Open Access Journals (Sweden)

    Anne F Peery

    Full Text Available Constipation, a low fiber diet, sedentary lifestyle and gravidity are commonly assumed to increase the risk of hemorrhoids. However, evidence regarding these factors is limited. We examined the association between commonly cited risk factors and the prevalence of hemorrhoids.We performed a cross sectional study of participants who underwent a colonoscopy in a colorectal adenoma prevention trial and who had a detailed assessment of bowel habits, diet and activity. The presence of hemorrhoids was extracted from the subjects' colonoscopy reports. We used logistic regression to estimate odds ratios and 95% confidence intervals while adjusting for age and sex.The study included 2,813 participants. Of these, 1,074 had hemorrhoids recorded. Constipation was associated with an increased prevalence of hemorrhoids (OR 1.43, 95% CI 1.11, 1.86. Of the fiber subtypes, high grain fiber intake was associated with a reduced risk (OR for quartile 4 versus quartile 1 = 0.78, 95% CI 0.62, 0.98. We found no association when comparing gravid and nulligravida women (OR 0.93, 95% CI 0.62-1.40. Sedentary behavior was associated with a reduced risk (OR 0.80, 95% CI 0.65-0.98, but not physical activity (OR 0.83, 95% CI 0.66-1.03. Neither being overweight nor obese was associated with the presence of hemorrhoids (OR 0.89, 95% CI 0.72-1.09 and OR 0.86, 95% CI 0.70-1.06.Constipation is associated with an increased risk of hemorrhoids. Gravidity and physical activity do not appear to be associated. High grain fiber intake and sedentary behavior are associated with a decreased risk of hemorrhoids.

  4. Risk Factors for Hemorrhoids on Screening Colonoscopy.

    Science.gov (United States)

    Peery, Anne F; Sandler, Robert S; Galanko, Joseph A; Bresalier, Robert S; Figueiredo, Jane C; Ahnen, Dennis J; Barry, Elizabeth L; Baron, John A

    2015-01-01

    Constipation, a low fiber diet, sedentary lifestyle and gravidity are commonly assumed to increase the risk of hemorrhoids. However, evidence regarding these factors is limited. We examined the association between commonly cited risk factors and the prevalence of hemorrhoids. We performed a cross sectional study of participants who underwent a colonoscopy in a colorectal adenoma prevention trial and who had a detailed assessment of bowel habits, diet and activity. The presence of hemorrhoids was extracted from the subjects' colonoscopy reports. We used logistic regression to estimate odds ratios and 95% confidence intervals while adjusting for age and sex. The study included 2,813 participants. Of these, 1,074 had hemorrhoids recorded. Constipation was associated with an increased prevalence of hemorrhoids (OR 1.43, 95% CI 1.11, 1.86). Of the fiber subtypes, high grain fiber intake was associated with a reduced risk (OR for quartile 4 versus quartile 1 = 0.78, 95% CI 0.62, 0.98). We found no association when comparing gravid and nulligravida women (OR 0.93, 95% CI 0.62-1.40). Sedentary behavior was associated with a reduced risk (OR 0.80, 95% CI 0.65-0.98), but not physical activity (OR 0.83, 95% CI 0.66-1.03). Neither being overweight nor obese was associated with the presence of hemorrhoids (OR 0.89, 95% CI 0.72-1.09 and OR 0.86, 95% CI 0.70-1.06). Constipation is associated with an increased risk of hemorrhoids. Gravidity and physical activity do not appear to be associated. High grain fiber intake and sedentary behavior are associated with a decreased risk of hemorrhoids.

  5. Bibliographic review, indication guidelines of colonoscopy and its application in Costa Rica

    International Nuclear Information System (INIS)

    Vargas Perez, Carmen

    2013-01-01

    A review of the available evidence is realized at around the appropriate indications and quality criteria in colonoscopy. This review has served as instrument to programs of early detection, diagnostic and treatment of colonic diseases in endoscopy units and endoscopists that have effected colonoscopy. Colorectal cancer (CRC) has been a preventable disease based on the effects of manipulable risk factors and screening for early detection of the same. Family history, older age, male sex, the number of size of adenomas, the presence of a villous component, high grade dysplasia and proximal location are associated with a significantly increased of the risk for CRC. Inappropriate/unnecessary indication of the procedure and lack of criteria uniformity, ignoring the international clinical guidelines of colonoscopy indication, has caused a collapse of endoscopy units in the world to the prejudice of the quality. Applicable quality indicators are defined to establish locally based on the available evidence, the minimum requirements that must meet endoscopy units and endoscopists that have participated in CRC screening programs. A preferred strategy or protocol of indication and monitoring is proposed to contemplate the evaluable quality criteria. Quality indicators of colonoscopy have allowed to optimize resources and determine the variability of the compliance between hospitals, endoscopy units or endoscopists and to identify deficiencies to plan improvement strategies. The medical criteria adequately base and individualized has prevailed in the diagnostic strategy decision. A constant evaluation of the performance in endoscopy units should be developed according to criteria of international quality. The protocolization and uniformity of criteria and concepts of the reference system for colonoscopy and post realization report, have been the key to adequate communication between health professionals and the patient. Alternative and complementary studies have been part of

  6. Virtual CT-colonoscopy. Examination technique, limitations, and prospects

    International Nuclear Information System (INIS)

    Springer, P.; Dessl, A.; Giacomuzzi, S.M.; Stoehr, B.; Stoeger, A.; Bodner, G.; Buchberger, W.

    1997-01-01

    Virtual CT-colonoscopy is a post-processing method which allows for reconstruction of inner bowel surface structures from helical CT datasets. The reconstructed images simulate the views which are known from fiberoptic endoscopy. Since colorectal cancer is the second main cause of death in USA and Europe today and since recent screening recommendations are often ignored by the public, a non-invasive or minimal-invasive procedure for colonic evaluation would offer some benefits. Virtual CT-colonoscopy generally involves three essential steps: patient preparation with cleansing of the bowel and administration of an air enema, helical CT-examination by using appropriate scan parameters, and interactive 3D rendering of the volume dataset. Although recent studies have demonstrated that polypoid lesions of about 5 mm size are well detectable and although virtual colonoscopy offers many advantages over fiberoptic endoscopy, some technical and clinical limitations must still be noted. Thus, the current inability of virtual colonoscopy to provide texture and color leads to problems in identifying flat lesions; the presence of retained or adherent fecal matter may result to false positive diagnosis and collapsed segments of bowel may cause problems as they cannot subsequently be evaluated during image reconstruction. Virtual endoscopy is still in its infancy and further technical and clinical development are necessary. (orig./AJ) [de

  7. Cross-sectional survey on awareness of colorectal cancer and a screening programme for primary health care professionals in Catalonia, Spain.

    Science.gov (United States)

    Benito, L; García, M; Binefa, G; Mila, N; Vidal, C; Lluch, M T; Puig, M

    2016-11-01

    This study aimed to assess whether primary health care professionals have accurate information regarding colorectal cancer (CRC) screening procedures, surveillance recommendations and referral strategies. This cross-sectional descriptive study was based on a survey conducted among primary health care professionals in Barcelona, Spain. The questionnaire was used to gather information regarding CRC screening procedures as well as demographic and professional characteristics of the study subjects. A CRC and screening awareness score (ranging from 0 to 12) was created based on the survey questions. The response rate was 58.9% (206/305). The estimated mean score (standard deviation) was 8.43 (SD: 1.30). For four questions, more than 60% of the answers were incorrect: one related to risk factors, two concerning follow-up colonoscopy, and one related to surveillance. Only 30.8% of the participants believed that they were responsible for determining the appropriate surveillance intervals and for scheduling colonoscopies. Although the professionals had sufficient knowledge of CRC screening, professional knowledge of some aspects related to the major non-modifiable risk factors for the disease and surveillance colonoscopy procedures could be improved. Frequent communication with professionals is necessary to maintain updated screening-related information. Possible methods for facilitating communication could include continuous briefings, regular message reminders or educational websites. © 2016 John Wiley & Sons Ltd.

  8. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Min Jung; Chung, Jae Joon; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1998-01-01

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  9. Quality of Colonoscopy Performed in Rural Practice: Experience From the Clinical Outcomes Research Initiative and the Oregon Rural Practice-Based Research Network.

    Science.gov (United States)

    Holub, Jennifer L; Morris, Cynthia; Fagnan, Lyle J; Logan, Judith R; Michaels, LeAnn C; Lieberman, David A

    2018-02-01

    Colon cancer screening is effective. To complete screening in 80% of individuals over age 50 years by 2018 will require adequate colonoscopy capacity throughout the country, including rural areas, where colonoscopy providers may have less specialized training. Our aim was to study the quality of colonoscopy in rural settings. The Clinical Outcomes Research Initiative (CORI) and the Oregon Rural Practice-based Research Network (ORPRN) collaborated to recruit Oregon rural practices to submit colonoscopy reports to CORI's National Endoscopic Database (NED). Ten ORPRN sites were compared to non-ORPRN rural (n = 11) and nonrural (n = 43) sites between January 2009 and October 2011. Established colonoscopy quality measures were calculated for all sites. No ORPRN physicians were gastroenterologists compared with 82% of nonrural physicians. ORPRN practices reached the cecum in 87.4% of exams compared with 89.3% of rural sites (P = .0002) and 90.9% of nonrural sites (P 9mm 16.6% vs 18.7% (P = .106). ORPRN sites performed well on most colonoscopy quality measures, suggesting that high-quality colonoscopy can be performed in rural settings. © 2016 National Rural Health Association.

  10. Risk of metachronous neoplasia on surveillance colonoscopy in young patients with colorectal neoplasia.

    Science.gov (United States)

    Kim, Hyun Gun; Cho, Young-Seok; Cha, Jae Myung; Shin, Jeong Eun; Kim, Kyeong Ok; Yang, Hyo-Joon; Koo, Hoon Sup; Joo, Young-Eun; Boo, Sun-Jin

    2018-03-01

    Few prior reports exist that address the appropriate colonoscopy surveillance interval for individuals  .1). In the baseline low-risk adenoma group (n = 1869), the 5-year risk of metachronous advanced neoplasia was 4.9% in the younger patients on screening colonoscopy and 5.1% in the older patients (P > .1). Similarly, in the baseline no neoplasia group (n = 7013), the 5-year risk of metachronous advanced neoplasia was 4.1% in the younger patients on screening colonoscopy and 5.6% in the older patients (P > .1). Considering the similar risk of metachronous advanced neoplasia in younger and older individuals, we suggest a 3-year surveillance interval for high-risk adenoma and a 5-year surveillance interval for low-risk adenoma in young individuals without a strong family history. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Colonoscopy uptake for high-risk individuals with a family history of colorectal neoplasia: A multicenter, randomized trial of tailored counseling versus standard information.

    Science.gov (United States)

    Ingrand, Isabelle; Defossez, Gautier; Richer, Jean-Pierre; Tougeron, David; Palierne, Nicolas; Letard, Jean-Christophe; Beauchant, Michel; Ingrand, Pierre

    2016-08-01

    Colonoscopic screening is recommended for first-degree relatives of patients diagnosed with colorectal cancer (CRC) or colorectal adenomatous polyps (CAP) before the age of 60 years. This has the potential to reduce CRC-related morbidity and mortality, but uptake is currently inadequate. The aim of the study was to compare the effectiveness of standard information versus a nurse-led tailored intervention designed to promote uptake of colonoscopy screening by siblings of CRC or CAP patients. A randomized controlled trial was conducted. Digestive surgeons and gastroenterologists recruited index patients who developed CRC or CAP before the age of 60 years. All index patients received standard screening information for their siblings, in keeping with current guidelines. Centrally computerized randomization of index patients resulted in allocating all their siblings to the same group, intervention or control. The tailored intervention targeted the index patient first, to help them convey information to their siblings. The nurse then provided the siblings with tailored information based on their answers to a self-questionnaire which explored health behaviors, derived from psychosocial models of prevention. Then the siblings were given a personalized information leaflet to hand to their regular physician. The primary endpoint was the rate of documented colonoscopy performed in siblings within 1 year after diagnosis of the index patient. The intent-to-treat analysis included siblings who refused to participate in the study. Statistical analysis was adjusted for intrafamilial correlation. A total of 304 siblings of 125 index patients were included: 160 in the intervention group and 144 in the control group. The rate of colonoscopy uptake among siblings was 56.3% in the intervention group and 35.4% in the control group (P = 0.0027). The respective rates after exclusion of refusals were 69.2% and 37.0% (P group (1 invasive cancer and 11 advanced adenomas vs 5 advanced

  12. Quality of colonoscopy and spectrum of lower gastrointestinal disease as determined by colonoscopy

    International Nuclear Information System (INIS)

    Rehman, K.U.; Qureshi, M.O.; Salih, M.

    2015-01-01

    To document the quality of colonoscopy practice and the pattern of colonic disease including polyp detection rate at Shifa International Hospital, Islamabad, Pakistan. Study Design: An observational study. Place and Duration of Study: Shifa International Hospital, Islamabad, Pakistan, from May 2013 to June 2014. Methodology: This retrospective study recorded demographics of patients, indications and quality indices of 505 colonoscopies performed during the study period. Preparation was done with low residue diet and polyethylene glycol. Conscious sedation was generally used. Quality indices studied were compared with guideline standard. Results:Out of 505 colonoscopy patients, 305 were males and 200 were females. The indications for colonoscopic examination were lower gastrointestinal bleeding (26.5%, n=134), screening for colorectal cancer (14.1%, n=71), chronic diarrhea (12.9%, n=65), abdominal pain (10.9%, n=55), anemia (9.1%, n=46), constipation (7.3%, n=37), hematochezia and diarrhea (6.3%, n=32), altered bowel habits (5.1%, n=26), weight loss (3.6%, n=18), colonic thickening on CT scan (3.0%, n=15) and others (1.2%, n=6). Bowel preparation was adequate (in 92%, n=465) cases. Cecal intubation rate was 88.71% (n=448). Endoscopic diagnoses were hemorrhoids (36.2%, n=183), normal (22%, n=111), polyps (11.3%, n=57), ulcerative colitis (8.7%, n=44), cancer (4%, n=20), diverticulosis (3.4%, n=17), infective colitis (2.6%, n=13), intestinal TB (2.6%, n=13), non-specific colitis (2.2%, n=11), proctitis (1.8%, n=9) and others (5.3%, n=27). Conclusion: There is room for improvement in quality of colonoscopy, cecal intubation rate is slightly below the recommended standard and polyp detection rate is quite low however, it is not clear if the low rate of polyp detection is due to missed lesions or low population incidence. Time to reach caecum and withdrawal time should clearly be documented in the notes which can help to evaluate quality of the procedure in a better way

  13. Projected national impact of colorectal cancer screening on clinical and economic outcomes and health services demand.

    Science.gov (United States)

    Ladabaum, Uri; Song, Kenneth

    2005-10-01

    Colorectal cancer (CRC) screening is effective and cost-effective, but the potential national impact of widespread screening is uncertain. It is controversial whether screening colonoscopy can be offered widely and how emerging tests may impact health services demand. Our aim was to produce integrated, comprehensive estimates of the impact of widespread screening on national clinical and economic outcomes and health services demand. We used a Markov model and census data to estimate the national consequences of screening 75% of the US population with conventional and emerging strategies. Screening decreased CRC incidence by 17%-54% to as few as 66,000 cases per year and CRC mortality by 28%-60% to as few as 23,000 deaths per year. With no screening, total annual national CRC-related expenditures were 8.4 US billion dollars. With screening, expenditures for CRC care decreased by 1.5-4.4 US billion dollars but total expenditures increased to 9.2-15.4 US billion dollars. Screening colonoscopy every 10 years required 8.1 million colonoscopies per year including surveillance, with other strategies requiring 17%-58% as many colonoscopies. With improved screening uptake, total colonoscopy demand increased in general, even assuming substantial use of virtual colonoscopy. Despite savings in CRC care, widespread screening is unlikely to be cost saving and may increase national expenditures by 0.8-2.8 US billion dollars per year with conventional tests. The current national endoscopic capacity, as recently estimated, may be adequate to support widespread use of screening colonoscopy in the steady state. The impact of emerging tests on colonoscopy demand will depend on the extent to which they replace screening colonoscopy or increase screening uptake in the population.

  14. Achieving a complete colonic evaluation in patients with incomplete colonoscopy is worth the effort.

    Science.gov (United States)

    Ridolfi, Timothy J; Valente, Michael A; Church, James M

    2014-03-01

    Patients with an incomplete colonoscopy are potentially at risk for missed lesions. The purpose of this work was to identify the percentage of patients completing colonic evaluation after incomplete colonoscopy, the manner in which the evaluation was completed, and the incidence of significant pathology. This was a retrospective analysis of prospectively collected data. The study was conducted in an outpatient colonoscopy clinic in the colorectal surgery department of a tertiary referral center. Patients included those undergoing incomplete colonoscopy from a database of 25,645 colonoscopies performed from 1982 to 2009. Procedures aimed at completing colorectal evaluation were included in the study. Reason for incompletion, secondary study, its success, and findings were measured. A total of 242 patients with incomplete colonoscopies were identified; 166 (69%) were women. The average age of patients was 59 years. Most frequent causes for incomplete colonoscopy were inadequate preparation (34%), pain (30%), and tortuosity (20%). The scope could not pass the splenic flexure in 165 patients (71%). A total of 218 patients (90%) were offered completion studies, and 179 patients (82%) complied. Seventy-three of 82 patients who had a surveillance colonoscopy had a follow-up (89%), compared with 72 (87%) of 83 with symptoms and 40 (74%) of 54 who had a screening. Barium enema (BE) was performed in 74 (41%), repeat colonoscopy in 71 (40%), CT colonography in 17 (9%), and colonoscopy under general anesthesia in 9 patients (5%). Resection with intraoperative/perioperative colonoscopy was required in 8 patients (4%). Repeat colonoscopy found 32 lesions (24 tubular adenomas, 4 tubulovillous adenomas, and 4 sessile serrated polyps) in 17 patients (24%). Radiology demonstrated new abnormalities in 11 (12%) of 91 patients, prompting 7 colonoscopies. In 3 patients, colonoscopy showed an inverted appendix, a tubulovillous adenoma, and a sigmoid stricture. Overall, clinically

  15. Repeat Colonoscopy within 6 Months after Initial Outpatient Colonoscopy in Ontario: A Population-Based Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Lawrence Paszat

    2017-01-01

    Full Text Available Background. The goal of this study is to examine utilization of early repeat colonoscopy ≤ 6 months after an index procedure. Methods. We identified persons having repeat colonoscopy ≤ 6 months following outpatient colonoscopy without prior colonoscopy ≤ 5 years or prior diagnosis of colorectal cancer (CRC. We modeled repeat colonoscopy using a generalized estimating equation with an exchangeable correlation structure to account for clustering of patients by endoscopist. Results. The population included 334,663 persons, 7,892 (2.36% of whom had an early repeat colonoscopy within 6 months. Overall, endoscopist prior year colonoscopy volume was inversely related to repeat ≤ 6 months. Repeat colonoscopy ≤ 6 months varied by the clinical setting of the index colonoscopy (adjusted OR = 1.41 (95% CI 1.29–1.55 at nonhospital facilities compared to teaching or community hospitals. Among those who had polypectomy or biopsy, the adjusted OR for early repeat ≤ 6 months was elevated among those whose index colonoscopy was at a nonhospital facility (OR 1.44, 95% CI 1.30–1.60, compared to those at a teaching hospital or community hospital. Conclusions. Repeat colonoscopy ≤ 6 months after an index procedure is associated with the clinical setting of the index colonoscopy.

  16. Prevalence of any size adenomas and advanced adenomas in 40- to 49-year-old individuals undergoing screening colonoscopy because of a family history of colorectal carcinoma in a first-degree relative.

    Science.gov (United States)

    Gupta, Akshay K; Samadder, Jewel; Elliott, Eric; Sethi, Saurabh; Schoenfeld, Philip

    2011-07-01

    Per current guidelines, patients with a first-degree relative (FDR) with colorectal cancer (CRC) should get screened at least at age 40. Data about the prevalence of adenomas and advanced adenomas (AAs) in these patients are lacking. To examine the prevalence of adenomas and AAs in 40- to 49-year-old individuals undergoing screening colonoscopy for family history of CRC. Retrospective chart review. Asymptomatic patients 40 to 49 years of age undergoing their first screening colonoscopy at the University of Michigan during the period 1999 to 2009 because of an FDR with CRC. Prevalence of adenomas (any size), AAs, and risk factors associated with adenomas. Among 640 study patients, the prevalence of adenomas (any size) was 15.4% and 3.3% for AAs. Adenoma prevalence was lower if the FDR with CRC was younger than 60 years of age versus an FDR with CRC older than 60 years of age (12.4% vs 19%, P = .034). Male sex (odds ratio 2.6; 95% CI, 1.06-4.4) and advancing age (odds ratio 1.16; 95% CI, 1.03-1.31) were associated with adenomas. Limited data on risk factor exposure and insufficient sample size to assess risk factors for AAs. Among 40- to 49-year-old patients undergoing screening colonoscopy because of an FDR with CRC, the prevalence of adenomas and AAs is low. Further research should determine whether these individuals have a higher prevalence of adenomas compared with average-risk individuals. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. User's perspectives of barriers and facilitators to implementing quality colonoscopy services in Canada: a study protocol.

    Science.gov (United States)

    Jobin, Gilles; Gagnon, Marie Pierre; Candas, Bernard; Dubé, Catherine; Ben Abdeljelil, Anis; Grenier, Sonya

    2010-11-02

    Colorectal cancer (CRC) represents a serious and growing health problem in Canada. Colonoscopy is used for screening and diagnosis of symptomatic or high CRC risk individuals. Although a number of countries are now implementing quality colonoscopy services, knowledge synthesis of barriers and facilitators perceived by healthcare professionals and patients during implementation has not been carried out. In addition, the perspectives of various stakeholders towards the implementation of quality colonoscopy services and the need of an efficient organisation of such services have been reported in the literature but have not been synthesised yet. The present study aims to produce a comprehensive synthesis of actual knowledge on the barriers and facilitators perceived by all stakeholders to the implementation of quality colonoscopy services in Canada. First, we will conduct a comprehensive review of the scientific literature and other published documentation on the barriers and facilitators to implementing quality colonoscopy services. Standardised literature searches and data extraction methods will be used. The quality of the studies and their relevance to informing decisions on colonoscopy services implementation will be assessed. For each group of users identified, barriers and facilitators will be categorised and compiled using narrative synthesis and meta-analytical techniques. The principle factors identified for each group of users will then be validated for its applicability to various Canadian contexts using the Delphi study method. Following this study, a set of strategies will be identified to inform decision makers involved in the implementation of quality colonoscopy services across Canadian jurisdictions. This study will be the first to systematically summarise the barriers and facilitators to implementation of quality colonoscopy services perceived by different groups and to consider the local contexts in order to ensure the applicability of this

  18. Understanding intention to undergo colonoscopy among intermediate-risk siblings of colorectal cancer patients: a test of a mediational model.

    Science.gov (United States)

    Manne, Sharon; Markowitz, Arnold; Winawer, Sidney; Guillem, Jose; Meropol, Neal J; Haller, Daniel; Jandorf, Lina; Rakowski, William; Babb, James; Duncan, Terry

    2003-01-01

    There is a need for research to identify factors influencing intentions to undergo colorectal cancer (CRC) screening among family members at risk for CRC. This study tested a mediational model primarily guided by Ronis' elaboration of the Health Belief Model in predicting intention to have colorectal cancer screening among siblings of individuals diagnosed with colorectal cancer prior to age 56 years. Data were collected from 534 siblings of individuals diagnosed with CRC. A baseline survey was administered by telephone. Measures included perceived susceptibility, CRC severity, physician and family support for CRC screening, cancer-specific distress, the closeness of the relationship with the affected sibling, and future intention to have a colonoscopy. Participant age, gender, and number of prior colonoscopies, as well as the stage of the affected patient's cancer and time from the patient's diagnosis to the interview, were controlled for in the analyses. The proposed model was not a good fit to the data. A respecified model was fit to the data. In this model, physician support, family support, and sibling closeness were significantly associated with both perceived benefits and barriers. Perceived severity was associated with barriers. Benefits and barriers, as well as cancer-specific distress, were directly associated with colonoscopy intentions. Results were consistent with a mediational role for benefits and barriers in the associations of sibling closeness and with a mediational role for barriers in the association between perceived severity and colonoscopy intentions. Family and physician support impacted intentions both directly and indirectly through effects on benefits and barriers. Perceived risk was not associated with benefits, barriers, or colonoscopy intentions. Intervention efforts to increase colonoscopy intentions may benefit from targeting family influences, particularly the affected proband in the family, as well as physician influence, cancer

  19. Educational Colonoscopy Video Enhances Bowel Preparation Quality and Comprehension in an Inner City Population.

    Science.gov (United States)

    Pillai, Ajish; Menon, Radha; Oustecky, David; Ahmad, Asyia

    2017-07-24

    Quality of bowel preparation and patient knowledge remains a major barrier for completing colorectal cancer screening. Few studies have tested unique ways to impact patient understanding centering on interactive computer programs, pictures, and brochures. Two studies explored instructional videos but focused on patient compliance and anxiety as endpoints. Furthermore, excessive video length and content may limit their impact on a broad patient population. No study so far has studied a video's impact on preparation quality and patient understanding of the colonoscopy procedure. We conducted a single blinded prospective study of inner city patients presenting for a first time screening colonoscopy. During their initial visit patients were randomized to watch an instructional colonoscopy video or a video discussing gastroesophageal reflux disease (GERD). All patients watched a 6 minutes long video with the same spokesperson, completed a demographic questionnaire (Supplemental Digital Content 1, http://links.lww.com/JCG/A352) and were enrolled only if screened within 30 days of their visit. On the day of the colonoscopy, patients completed a 14 question quiz of their knowledge. Blinded endoscopist graded patient preparations based on the Ottawa scale. All authors had access to the study data and reviewed and approved the final manuscript. Among the 104 subjects enrolled in the study, 56 were in the colonoscopy video group, 48 were in GERD video group, and 12 were excluded. Overall, 48% were male and 52% female; 90% of patients had less than a high school education, 76% were African American, and 67% used a 4 L split-dose preparation. There were no differences between either video group with regard to any of the above categories. Comparisons between the 2 groups revealed that the colonoscopy video group had significantly better Ottawa bowel preparation score (4.77 vs. 6.85; P=0.01) than the GERD video group. The colonoscopy video group also had less-inadequate repeat

  20. Colonoscopic screening for colorectal cancer improves quality of life measures: a population-based screening study

    Directory of Open Access Journals (Sweden)

    Shadbolt Bruce

    2006-10-01

    Full Text Available Abstract Background Screening asymptomatic individuals for neoplasia can have adverse consequences on quality of life. Colon cancer screening is widespread but the quality of life (QOL consequences are unknown. This study determined the impact of screening colonoscopy on QOL measures in asymptomatic average-risk participants. Methods Asymptomatic male and female participants aged 55–74 years were randomly selected from the Australian Electoral Roll or six primary care physicians' databases. Participants completed the Short-Form (SF-36 Quality of Life Assessment at baseline and at a mean of 39 days after colonoscopy. Outcome measures were (i significant changes in raw scores in any of the eight SF-36 domains assessed following colonoscopic screening and (ii improvements or declines in previously validated categories, representing clinically significant changes, within any of the eight SF-36 domains. Results Baseline QOL measures were similar to those of a matched general population sample. Role Limitations due to Emotions, Mental Health and Vitality raw scores significantly improved following colonoscopy (P Conclusion Average-risk persons benefit significantly from colon cancer screening with colonoscopy, improving in Mental Health and Vitality domains of Quality of Life. This improvement is not offset by declines in other domains.

  1. The corner of the gastroenterologist: What colonoscopy can do, what to ask to radiologist

    International Nuclear Information System (INIS)

    Bennato, Raffaele; Balzano, Antonio

    2007-01-01

    Colonoscopy is the diagnostic technique of choice for most colonic diseases and allows to explore the entire colonic mucosal surface and to visualize the mucosa of terminal ileum. When it is done with appropriate indications, significantly more clinically relevant diagnoses are made. Moreover, colonoscopy keeps an operative role in the treatment of some acute and chronic colonic diseases and it is the most effective colorectal cancer screening modality. The endoscopic exploration of colon is not infallible and presents rare complications. Programs of endoscopic training and practice, monitoring of quality indicators and continuous technological development are improving endoscopic diagnostic and therapeutic role. Appropriate indications for colonoscopy, its limits and complications and questions for the radiologist are discussed

  2. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals

    DEFF Research Database (Denmark)

    Kobaek-Larsen, Morten; Kroijer, Rasmus; Dyrvig, Anne-Kirstine

    2018-01-01

    mm polyps in colon capsule endoscopy (97%; 95% CI: 94-100) was superior to colonoscopy (89%; 95% CI: 84-94). A complete capsule endoscopy examination (N=134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity...... and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp >10 mm or more than two polyps. CONCLUSION: Colon capsule endoscopy is superior to colonoscopy in polyp detection rate and per-patient sensitivity to >9 mm polyps, but only in complete CCE examinations. The rate...

  3. Unsedation colonoscopy can be not that painful: Evaluation of the effect of "Lamaze method of colonoscopy".

    Science.gov (United States)

    Yu, Shao-Ping; Lin, Xiao-Dong; Wu, Guang-Yao; Li, Song-Hu; Wen, Zong-Quan; Cen, Xiao-Hong; Huang, Xian-Guang; Huang, Mei-Ting

    2015-10-25

    To evaluate the pain relieving effect of intervention with "Lamaze method of colonoscopy" in the process of colonoscopy. Five hundred and eighty-five patients underwent colonoscopy were randomly divided into three groups, Lamaze group, anesthetic group and control group. Two hundred and twenty-four patients of Lamaze group, the "Lamaze method of colonoscopy" were practiced in the process of colonoscopy. The Lamaze method of colonoscopy is modified from the Lamaze method of childbirth, which helped patients to relieve pain through effective breathing control. One hundred and seventy-eight patients in anesthetic group accepted sedation colonoscopy. For 183 patients in control group, colonoscopy was performed without any intervention. The satisfactory of colon cleaning, intestinal lesions, intubation time, success ratio, pain grading and complications were recorded. All data were statistically analyzed. There were no significant differences at base line of the three groups (P > 0.05). Anesthetic group shows advantage in intubation time than the other two groups (P advantage in intubation time than that in control group (P > 0.05). The anesthetic group showed an apparent advantage in relieving pain (P promotion in clinical practice.

  4. Technological advances for improving adenoma detection rates: The changing face of colonoscopy.

    Science.gov (United States)

    Ishaq, Sauid; Siau, Keith; Harrison, Elizabeth; Tontini, Gian Eugenio; Hoffman, Arthur; Gross, Seth; Kiesslich, Ralf; Neumann, Helmut

    2017-07-01

    Worldwide, colorectal cancer is the third commonest cancer. Over 90% follow an adenoma-to-cancer sequence over many years. Colonoscopy is the gold standard method for cancer screening and early adenoma detection. However, considerable variation exists between endoscopists' detection rates. This review considers the effects of different endoscopic techniques on adenoma detection. Two areas of technological interest were considered: (1) optical technologies and (2) mechanical technologies. Optical solutions, including FICE, NBI, i-SCAN and high definition colonoscopy showed mixed results. In contrast, mechanical advances, such as cap-assisted colonoscopy, FUSE, EndoCuff and G-EYE™, showed promise, with reported detections rates of up to 69%. However, before definitive recommendations can be made for their incorporation into daily practice, further studies and comparison trials are required. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  5. Expert opinions and scientific evidence for colonoscopy key performance indicators.

    Science.gov (United States)

    Rees, Colin J; Bevan, Roisin; Zimmermann-Fraedrich, Katharina; Rutter, Matthew D; Rex, Douglas; Dekker, Evelien; Ponchon, Thierry; Bretthauer, Michael; Regula, Jaroslaw; Saunders, Brian; Hassan, Cesare; Bourke, Michael J; Rösch, Thomas

    2016-12-01

    Colonoscopy is a widely performed procedure with procedural volumes increasing annually throughout the world. Many procedures are now performed as part of colorectal cancer screening programmes. Colonoscopy should be of high quality and measures of this quality should be evidence based. New UK key performance indicators and quality assurance standards have been developed by a working group with consensus agreement on each standard reached. This paper reviews the scientific basis for each of the quality measures published in the UK standards. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. High Efficacy of Repeating Colonoscopy by an Advanced Endoscopist after an Incomplete Colonoscopy

    OpenAIRE

    Ana Ponte; Rolando Pinho; Adélia Rodrigues; Luísa Proença; Joana Silva; Jaime P. Rodrigues; Mafalda Sousa; João Carlos Silva; João Carvalho

    2018-01-01

    Background and Aims: This study aims to evaluate the role of an advanced endoscopist to study the entire colon after an incomplete colonoscopy. Methods: All patients with an elective incomplete colonoscopy performed under deep sedation in our department between January 2010 and October 2016 were included. Patients with a colonic stenosis, an inadequate bowel preparation, or a colonoscopy performed without deep sedation were excluded. Included patients were followed up to evaluate if and what ...

  7. A centrally generated primary care physician audit report does not improve colonoscopy uptake after a positive result on a fecal occult blood test in Ontario's ColonCancerCheck program.

    Science.gov (United States)

    Stock, D; Rabeneck, L; Baxter, N N; Paszat, L F; Sutradhar, R; Yun, L; Tinmouth, J

    2017-02-01

    Timely follow-up of fecal occult blood screening with colonoscopy is essential for achieving colorectal cancer mortality reduction. In the present study, we evaluated the effectiveness of centrally generated, physician-targeted audit and feedback to improve colonoscopy uptake after a positive fecal occult blood test (fobt) result within Ontario's population-wide ColonCancerCheck Program. This prospective cohort study used data sets from Ontario's ColonCancerCheck Program (2008-2011) that were linked to provincial administrative health databases. Cox proportional hazards regression was used to estimate the effect of centralized, physician-targeted audit and feedback on colonoscopy uptake in an Ontario-wide fobt-positive cohort. A mailed physician audit and feedback report identifying individuals outstanding for colonoscopy for 3 or more months after a positive fobt result did not increase the likelihood of colonoscopy uptake (hazard ratio: 0.95; 95% confidence interval: 0.79 to 1.13). Duration of positive fobt status was strongly inversely associated with the hazard of follow-up colonoscopy ( p for linear trend: audit and feedback reports does not improve colonoscopy uptake for screening participants with a positive fobt result outstanding for 3 or more months. Mailed physician-targeted screening audit and feedback reports alone are unlikely to improve compliance with follow-up colonoscopy in Ontario. Other interventions such as physician audits or automatic referrals, demonstrated to be effective in other jurisdictions, might be warranted.

  8. Post-colonoscopy colorectal cancer rate in the era of high-definition colonoscopy.

    Science.gov (United States)

    Iwatate, Mineo; Kitagawa, Tomoyuki; Katayama, Yasumi; Tokutomi, Naohiko; Ban, Shinichi; Hattori, Santa; Hasuike, Noriaki; Sano, Wataru; Sano, Yasushi; Tamano, Masaya

    2017-11-14

    To investigate the post-colonoscopy colorectal cancer (PCCRC) rate for high-definition (HD) colonoscopy compared with that for standard-definition colonoscopy reported previously. Using medical records at Sano Hospital (SH) and Dokkyo Medical University Koshigaya Hospital (DMUKH), we retrospectively obtained data on consecutive patients diagnosed as having CRC between January 2010 and December 2015. The definition of PCCRC was diagnosis of CRC between 7 and 36 mo after initial high-definition colonoscopy that had detected no cancer, and patients were divided into a PCCRC group and a non-PCCRC group. The primary outcome was the rate of PCCRC for HD colonoscopy. The secondary outcomes were factors associated with PCCRC and possible reason for occurrence of early and advanced PCCRC. Among 892 CRC patients, 11 were diagnosed as having PCCRC and 881 had non-PCCRC. The PCCRC rate was 1.7% (8/471) at SH and 0.7% (3/421) at DMUKH. In comparison with the non-PCCRC group, the PCCRC group had a significantly higher preponderance of smaller tumors (39 mm vs 19 mm, P = 0.002), a shallower invasion depth (T1 rate, 25.4% vs 63.6%, P = 0.01), a non-polypoid macroscopic appearance (39.0% vs 85.7%, P = 0.02) and an earlier stage (59.7% vs 90.9%, P = 0.03). Possible reasons for PCCRC were "missed or new" in 9 patients (82%), "incomplete resection" in 1 (9%), and "inadequate examination'" in 1 (9%). Among 9 "missed or new" PCCRC, the leading cause was non-polypoid shape for early PCCRC and blinded location for advanced PCCRC. The PCCRC rate for HD colonoscopy was 0.7%-1.7%, being lower than that for standard-definition colonoscopy (1.8%-9.0%) reported previously employing the same methodology.

  9. Development and Testing of an Automated 4-Day Text Messaging Guidance as an Aid for Improving Colonoscopy Preparation.

    Science.gov (United States)

    Walter, Benjamin Michael; Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan

    2016-06-21

    In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective of this study was to assess the function of an automated text messaging (short message service, SMS)-supported colonoscopy preparation starting 4 days before colonoscopy appointment. After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging-provided information assessed by a questionnaire. Web-based SMS text messaging-supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging-based information was high. Using SMS for colonoscopy preparation with 4 days' guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy

  10. Stability of negative ionization fronts: Regularization by electric screening?

    International Nuclear Information System (INIS)

    Arrayas, Manuel; Ebert, Ute

    2004-01-01

    We recently have proposed that a reduced interfacial model for streamer propagation is able to explain spontaneous branching. Such models require regularization. In the present paper we investigate how transversal Fourier modes of a planar ionization front are regularized by the electric screening length. For a fixed value of the electric field ahead of the front we calculate the dispersion relation numerically. These results guide the derivation of analytical asymptotes for arbitrary fields: for small wave-vector k, the growth rate s(k) grows linearly with k, for large k, it saturates at some positive plateau value. We give a physical interpretation of these results

  11. Screening for colorectal cancer.

    Science.gov (United States)

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  12. The Polyp Manager: a new tool for optimal polyp documentation during colonoscopy. A pilot study.

    Science.gov (United States)

    van de Meeberg, Maartje M.; Ouwendijk, Rob J. Th.; ter Borg, Pieter C. J.; van den Hazel, Sven J.; van de Meeberg, Paul C.

    2016-01-01

    Background and study aims: Conventional reporting of polyps is often incomplete. We tested the Polyp Manager (PM), a new software application permitting the endoscopist to document polyps in real time during colonoscopy. We studied completeness of polyp descriptions, user-friendliness and the potential time benefit. Patients and methods: In two Dutch hospitals colonoscopies were performed with PM (as a touchscreen endoscopist-operated device or nurse-operated desktop application). Completeness of polyp descriptions was compared to a historical group with conventional reporting (CRH). Prospectively, we compared user-friendliness (VAS-scores) and time benefit of the endoscopist-operated PM to conventional reporting (CR) in one hospital. Duration of colonoscopy and time needed to report polyps and provide a pathology request were measured. Provided that using PM does not prolong colonoscopy, the sum of the latter two was considered as a potential time-benefit if the PM were fully integrated into a digital reporting system. Results: A total of 144 regular colonoscopies were included in the study. Both groups were comparable with regard to patient characteristics, duration of colonoscopy and number of polyps. Using the PM did reduce incomplete documentation of the following items in CRH-reports: location (96 % vs 82 %, P = 0.01), size (95 % vs 89 %, P = 0.03), aspect (71 % vs 36 %, P < 0.001) and completeness of removal (61 % vs 37 %, P < 0.001). In the prospective study 23 PM-colonoscopies where compared to 28 CR-colonoscopies. VAS-scores were significantly higher in the endoscopist-operated PM group. Time to report was 01:27 ± 01:43 minutes (median + interquartile range) in the entire group (PM as CR), reflecting potential time benefit per colonoscopy. Conclusions: The PM is a user-friendly tool that seems to improve completeness of polyp reporting. Once integrated with digital reporting systems, it is probably time saving as

  13. Prospective Study of Combined Colon and Endometrial Cancer Screening in Women With Lynch Syndrome: A Patient-Centered Approach

    Science.gov (United States)

    Huang, Marilyn; Sun, Charlotte; Boyd-Rogers, Stephanie; Burzawa, Jennifer; Milbourne, Andrea; Keeler, Elizabeth; Yzquierdo, Rebecca; Lynch, Patrick; Peterson, Susan K.; Lu, Karen

    2011-01-01

    Background: Endometrial and colorectal cancers are the most common cancers in Lynch syndrome. Consensus guidelines recommend annual endometrial biopsy (EMB) and regular colonoscopies. We assessed the feasibility of concurrently performing EMB and colonoscopy and evaluated women's perception of pain, satisfaction, and acceptability. Methods: From July 2002 to December 2009, women who had a gene mutation for Lynch syndrome, met the Amsterdam II criteria, or had a high-risk situation that required screening were prospectively enrolled. After conscious sedation, the procedures were sequentially performed. Patients completed pre- and postprocedure questionnaires assessing pain, level of satisfaction, and acceptability. The Wilcoxon rank test and Mann-Whitney test were used to compare pain scores. Results: Forty-two women completed the study. Median age was 37 years (range, 25 to 73). Nineteen had previously had an EMB in the office setting. Women reported significantly lower median levels of pain in the combined procedure compared with previous office setting biopsies (P Lynch syndrome screening recommendations. PMID:21532810

  14. Colorectal Cancer Screening (PDQ®)—Patient Version

    Science.gov (United States)

    There are five types of tests that are used to screen for colorectal cancer: fecal occult blood test, sigmoidoscopy, colonoscopy, virtual colonoscopy, and DNA stool test. Learn more about these and other tests in this expert-reviewed summary.

  15. The effect of auricular acupuncture on pain during colonoscopy with midazolam and pethidine

    Science.gov (United States)

    Kusumastuti, R.; Srilestari, A.; Abdurrohim, K.; Abdullah, M.

    2017-08-01

    Colonoscopy is the standard procedure for colorectal cancer screening. One of its common complications is abdominal pain. Analgesia has not provided favorable outcomes so various complementary practices have been developed, including auricular acupuncture. In this study, a randomized controlled trial of 56 patients who underwent colonoscopy was conducted to determine the effect of acupuncture on the pain experienced during colonoscopy. Subjects were divided into two groups: The first received acupuncture combined with midazolam and pethidine, while the second were administered placebo puncture in addition to midazolam and pethidine. The median Critical Care Pain Observation Tool (CPOT) score was lower in the auricular acupuncture group than in the placebo puncture group(0.7 [0-4.83] vs. 1.9 [0-6.20] p = 0.010), while there were no significant differences to median Visual Analog Scale (VAS) scores (29 [0-100] vs. 44.5 [0-100] p = 0.147), heart rate changes (-2.58 [14.31] vs.-2.43 [12.28]; p = 0.970), or the mean time to the cecum (16 [8-51] vs. 22 [5-63] p = 0.206). Auricular acupuncture combined with midazolam and pethidine was found to be effective at reducing pain during colonoscopy.

  16. COLONOSCOPY AND CARCINOEMBRYONIC ANTIGEN VARIATIONS

    Directory of Open Access Journals (Sweden)

    Rita G SOUSA

    2014-03-01

    Full Text Available Context Colonoscopy is essential for synchronous and metachronous cancer detection. Carcinoembryonic antigen is a colorectal cancer tumor marker, important as a follow-up tool in patients with previous colorectal cancer. False-positive carcinoembryonic antigen elevation results in multiples exams and in patient anxiety. In literature, there is reference to transient carcinoembryonic antigen increase with colonoscopy. Objective To evaluate the influence of bowel preparation and colonoscopy in carcinoembryonic antigen blood levels. Methods We prospectively studied subjects that underwent routine colonoscopy in our institution. Blood samples were collected (1 before bowel cleaning, (2 before colonoscopy and (3 immediately after colonoscopy. Blood carcinoembryonic antigen levels were determined by “Sandwich” immunoassay. The statistical methods used were the paired t-test and ANOVA. Results Thirty-seven patients (22M/15F were included; age range 28-84 (mean 56 years. Mean carcinoembryonic antigen values were 1.9, 2 and 1.8 for (1, (2 and (3, respectively. An increase in value (2 compared with (1 was observed in 20/37 patients (P = 0.018, mainly in younger patients and in patients requiring more endoluminal interventions. In 29/37 patients, the CEA value decreased from (2 to (3 (P = 1.3x10-7. Conclusions A trend for carcinoembryonic antigen increase after bowel cleaning was observed, especially in younger patients and in patients with more endoluminal interventions, but without clinical meaning.

  17. Colonoscopy results are not enhanced by use of magnet endoguide in specialist practice

    DEFF Research Database (Denmark)

    Bak-Christensen, Anders; Knudsen, Elisabeth; Hendel, Jakob

    2013-01-01

    screening. UPD has been proposed as a tool for optimization of results and reduction of patient discomfort. In this study, we aimed to qualify the debate by examining the success rate and patient discomfort in an unselected colonoscopy population referred to specialist clinics with experienced investigators...

  18. Patients with History of Colonoscopy Are Less Likely to Achieve High Quality Preparation After Implementing Split-Dose Bowel Preparation.

    Science.gov (United States)

    Madhoun, M F; Bitar, H; Parava, P; Bashir, M H; Zia, H

    2017-01-01

    Anecdotally, we observed that patients who had previous colonoscopies were less likely to follow newly implemented split-dose bowel preparation (SDBP) instructions. We investigated whether the indication for colonoscopy is an independent factor for achieving high quality bowel preparation among patients asked to follow SDBP. We performed a retrospective study of data from 1478 patients who received outpatient colonoscopies in 2014 (the year of SDBP implementation) at our Veterans Affairs Medical Center. We collected information related to demographics and factors known to affect bowel preparations. Reasons for colonoscopy were dichotomized into surveillance (previous colonoscopy) vs. non-surveillance (positive occult blood test or screening). Bowel preparation quality was scored using the Boston Bowel Preparation Scale (BBPS), and was categorized as either excellent vs. not excellent (BBPS≥7 vs. BBPSquality was excellent in 60% of colonoscopies and adequate in 84% of colonoscopies. Thirty-six percent (535) were surveillance colonoscopies. In multivariate logistic regression analysis, more patients in the non-surveillance group achieved excellent (OR 0.8 ; 95% CI [0.7-0.8], P <0.0001) and adequate (OR 0.8 ; 95% CI [0.7-0.9], P <0.006) bowel preparation than did patients in the surveillance group. Patients with a prior colonoscopy might not follow the split-dose bowel preparation instructions. Educational interventions emphasizing the benefits of SDBP in this group of patients may help ensure compliance and prevent the habitual use of day-before preparations. © Acta Gastro-Enterologica Belgica.

  19. Colonoscopy and computerised tomography scan are not sufficient to localise right sided colonic lesions accurately.

    LENUS (Irish Health Repository)

    Solon, Jacqueline Gemma

    2009-11-23

    : Aim: accurate pre-operative localisation of colonic lesions is critical especially in laparoscopic colectomy where tactile localisation is absent particularly in screen-detected tumours. The study aimed to evaluate the accuracy of colonoscopy and double-contrast computerised tomography (CT) to localise lesions treated by right hemicolectomy. Method: a retrospective chart review was performed of patients treated by right hemicolectomy under the colorectal service between July 2003 and October 2006. Pre-operative tumour location determined by CT scan and colonoscopy were compared with the intra-operative and histopathologic findings. Results: of 101 patients, 73 (73%) were for adenoma or cancer, with a final diagnosis of adenocarcinoma in 59 (59%). Pre-operative localisation was inaccurate in 29% of lesions using both CT and colonoscopy. In the transverse colon colonoscopy alone was only 37.5% accurate, increasing to 62.5% when information from the CT scan was added. Conclusion: pre-operative localisation of right-sided colon cancers using colonoscopy and CT scanning is unreliable in at least 29% of cases. Inaccurate localisation of transverse colon tumours risks inadequate lymphadenectomy with an adverse cancer outcome. Pre-operative abdominal CT scan improves accuracy but endoscopic tattoo localisation should be employed routinely especially in patients undergoing laparoscopic resection.

  20. A randomized controlled trial of an educational video to improve quality of bowel preparation for colonoscopy.

    Science.gov (United States)

    Park, Jin-Seok; Kim, Min Su; Kim, HyungKil; Kim, Shin Il; Shin, Chun Ho; Lee, Hyun Jung; Lee, Won Seop; Moon, Soyoung

    2016-06-17

    High-quality bowel preparation is necessary for colonoscopy. A few studies have been conducted to investigate improvement in bowel preparation quality through patient education. However, the effect of patient education on bowel preparation has not been well studied. A randomized and prospective study was conducted. All patients received regular instruction for bowel preparation during a pre-colonoscopy visit. Those scheduled for colonoscopy were randomly assigned to view an educational video instruction (video group) on the day before the colonoscopy, or to a non-video (control) group. Qualities of bowel preparation using the Ottawa Bowel Preparation Quality scale (Ottawa score) were compared between the video and non-video groups. In addition, factors associated with poor bowel preparation were investigated. A total of 502 patients were randomized, 250 to the video group and 252 to the non-video group. The video group exhibited better bowel preparation (mean Ottawa total score: 3.03 ± 1.9) than the non-video group (4.21 ± 1.9; P educational video could improve the quality of bowel preparation in comparison with standard preparation method. Clinical Research Information Service KCT0001836 . The date of registration: March, 08(th), 2016, Retrospectively registered.

  1. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    NARCIS (Netherlands)

    Turenhout, S.T. van; Oort, F.A.; Terhaar sive Droste, J.S.; Coupe, V.M.; Hulst, R.W. van der; Loffeld, R.J.; Scholten, P.; Depla, A.C.; Bouman, A.A.; Meijer, G.A.; Mulder, C.J.; Rossum, L.G.M. van

    2012-01-01

    BACKGROUND: Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. OBJECTIVE: To determine the contribution of

  2. Risk perception among Brazilian individuals with high risk for colorectal cancer and colonoscopy

    Directory of Open Access Journals (Sweden)

    Santos Erika M

    2011-07-01

    Full Text Available Abstract Background Risk perception is considered a motivating factor for adopting preventive behaviors. This study aimed to verify the demographic characteristics and cancer family history that are predictors of risk perception and to verify if risk perception is a predictor of colonoscopy adherence. Methods Individuals with a family colorectal cancer history as indicated by a proband with cancer were interviewed by telephone. They responded to a questionnaire covering demographic characteristics, colonoscopy history and four questions on risk perception. Tests of multiple linear regression and logistic regression were used to identify associations between dependent and independent variables. Results The 117 participants belonged to 62 families and had a mean age of 45.2 years. The majority of these individuals were female (74.4% and from families who met the Amsterdam Criteria (54.7%. The average risk perception was 47.6%, with a median of 50%. The average population perception of individual risk was 55.4%, with a median of 50%. Variables associated with a higher risk perception were age, gender, religion, school level, income, and death of a family member. The variable predicting colonoscopy was receiving medical information regarding risk (odds ratio OR 8.40. Conclusions We found that family cancer history characteristics (number of relatives with cancer, risk classification are associated with adequate risk perception. Risk perception does not predict colonoscopy in this sample. The only variable that predicted colonoscopy was receiving medical information recommending screening.

  3. Quality in colonoscopy: European perspectives and practice

    NARCIS (Netherlands)

    Rees, Colin J.; Rajasekhar, Praveen T.; Rutter, Matthew D.; Dekker, Evelein

    2014-01-01

    Colonoscopy is the 'gold standard' investigation of the colon. High quality colonoscopy is essential to diagnose early cancer and reduce its incidence through the detection and removal of pre-malignant adenomas. In this review, we discuss the key components of a high quality colonoscopy, review

  4. MiraLAX is not as effective as GoLytely in bowel cleansing before screening colonoscopies.

    Science.gov (United States)

    Hjelkrem, Michael; Stengel, Joel; Liu, Mark; Jones, David P; Harrison, Stephen A

    2011-04-01

    Successful colonoscopies require good bowel preparations-poor bowel preparations can increase medical costs, rates of missed lesions, and procedure duration. The combination of polyethylene glycol (PEG) 3350 without electrolytes (MiraLAX; Schering-Plough Healthcare Products, Inc, Kenilworth, NJ) and 64 oz of Gatorade (PepsiCo, Inc, Purchase, NY) has gained popularity as a bowel preparation regimen. However, the efficacy and tolerability of this approach has not been compared with standard bowel preparations in clinical trials. We compared split-dose (PEG) 3350 with electrolytes (GoLytely; Braintree Laboratories, Inc, Braintree, MA) with split-dose MiraLAX alone and in combination with pretreatment medications (bisacodyl or lubiprostone) to determine the efficacy and patient tolerability of MiraLAX as an agent for bowel preparation. We performed a prospective, randomized, blinded, controlled trial at a tertiary care center. Patients (n=403) were randomly assigned to groups given GoLytely, MiraLAX, MiraLAX with bisacodyl (10 mg), or MiraLAX with lubiprostone (24 μg). MiraLAX was combined with 64 oz of Gatorade. All patients were surveyed regarding preparation satisfaction and tolerability. The Ottawa bowel preparation scale was used to grade colon cleanliness. GoLytely was more effective at bowel cleansing (average Ottawa score, 5.1) than MiraLAX alone (average Ottawa score, 6.9) or in combination with lubiprostone (average Ottawa score, 6.8), or bisacodyl (average Ottawa score, 6.3) (P<.001). MiraLAX was associated with a trend toward longer procedure duration (P=.096). Groups given MiraLAX rated the overall experience as more satisfactory than those given GoLytely (P<.001). There were no differences between polyp detection rates (P=.346) or adverse events (P=.823). Split-dose MiraLAX in 64 oz of Gatorade is not as effective as 4 L split-dose GoLytely in bowel cleansing for screening colonoscopies. Copyright © 2011 AGA Institute. Published by Elsevier Inc. All

  5. The Impact of Patient Education with a Smartphone Application on the Quality of Bowel Preparation for Screening Colonoscopy.

    Science.gov (United States)

    Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub

    2017-09-01

    Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p =0.007 by t -test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group.

  6. Cost-Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.

    Science.gov (United States)

    Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris

    2017-12-27

    Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared to the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon microsimulation model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess whether optimal screening strategies would change. Colonoscopy every 5 years, starting at age 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in population is not clear. Using a Microsimulation Screening Analysis-Colon microsimulation model, we found screening of patients with cystic fibrosis for CRC to be cost-effective. Due to the higher risk in these patients for CRC, screening should start at an earlier age with a shorter screening interval. The findings of this study

  7. Image-based path planning for automated virtual colonoscopy navigation

    Science.gov (United States)

    Hong, Wei

    2008-03-01

    Virtual colonoscopy (VC) is a noninvasive method for colonic polyp screening, by reconstructing three-dimensional models of the colon using computerized tomography (CT). In virtual colonoscopy fly-through navigation, it is crucial to generate an optimal camera path for efficient clinical examination. In conventional methods, the centerline of the colon lumen is usually used as the camera path. In order to extract colon centerline, some time consuming pre-processing algorithms must be performed before the fly-through navigation, such as colon segmentation, distance transformation, or topological thinning. In this paper, we present an efficient image-based path planning algorithm for automated virtual colonoscopy fly-through navigation without the requirement of any pre-processing. Our algorithm only needs the physician to provide a seed point as the starting camera position using 2D axial CT images. A wide angle fisheye camera model is used to generate a depth image from the current camera position. Two types of navigational landmarks, safe regions and target regions are extracted from the depth images. Camera position and its corresponding view direction are then determined using these landmarks. The experimental results show that the generated paths are accurate and increase the user comfort during the fly-through navigation. Moreover, because of the efficiency of our path planning algorithm and rendering algorithm, our VC fly-through navigation system can still guarantee 30 FPS.

  8. Tumor‐associated DNA mutation detection in individuals undergoing colonoscopy

    OpenAIRE

    Fleshner, Phillip; Braunstein, Glenn D.; Ovsepyan, Gayane; Tonozzi, Theresa R.; Kammesheidt, Anja

    2017-01-01

    Abstract The majority of colorectal cancers (CRC) harbor somatic mutations and epigenetic modifications in the tumor tissue, and some of these mutations can be detected in plasma as circulating tumor DNA (ctDNA). Precancerous colorectal lesions also contain many of these same mutations. This study examined plasma for ctDNA from patients undergoing a screening or diagnostic colonoscopy to determine the sensitivity and specificity of the ctDNA panel for detecting CRC and precancerous lesions. T...

  9. Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients

    International Nuclear Information System (INIS)

    Regge, D.; Martincich, L.; Gallo, T.; Pollone, M.; Galatola, G.; Secreto, P.; Pera, A.; Rivolta, A.

    2000-01-01

    Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps ≥ 1 cm. Virtual colonoscopy is an imaging modality with good diagnostic yield, well tolerated by patients and with great potentials for further development. It was suggested that the examination be performed in symptomatic patients who cannot undergo total colonoscopy or refuse the other imaging modalities. Further studies are waranted in larger series of patients, possibly introducing it in screening programs [it

  10. Computed tomography colonography versus colonoscopy for the diagnosis of colorectal cancer: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Duarte RB

    2018-02-01

    Full Text Available Ralph B Duarte, Wanderley M Bernardo, Christiano M Sakai, Gustavo LR Silva, Hugo G Guedes, Rogerio Kuga, Edson Ide, Robson K Ishida, Paulo Sakai, Eduardo GH de Moura Gastrointestinal Endoscopy Unit of Hospital das Clínicas of São Paulo University Medical School, São Paulo, SP, Brazil Abstract: Colorectal cancer (CRC is a significant cause of morbidity and mortality. Optical colonoscopy (OC is the first choice of investigation for assessing the state of the colon and it is excellent for CRC screening. Newer technologies such as computed tomography colonography (CTC may also be useful in CRC screening. This systematic review compares the benefits of CTC and OC for CRC screening. This review includes all the available randomized clinical trials comparing CTC and OC for CRC screening in asymptomatic patients. Three studies were included in the systematic review and were submitted for meta-analysis. In the analysis of participation rates, only 2,333 of 8,104 (29% patients who were invited for screening underwent the CTC, and only 1,486 of the 7,310 (20% patients who were invited for screening underwent OC. The absolute risk difference in participation rate in the two procedures was 0.1 (95% CI, 0.05–0.14 in favor of CTC. In the analysis of advanced colorectal neoplasia (ACN detection rates, 2,357 patients undergoing CTC and 1,524 patients undergoing OC were included. Of these, 135 patients (5.7% who underwent a CTC and 130 patients (8.5% who underwent an OC were diagnosed with ACN. The absolute risk difference in ACN detection rate in the two procedure types was -0.02 (with a 95% CI between -0.04 and -0.00 in favor of OC. CTC is an option for CRC screening in asymptomatic patients. However, as CTC was inferior in detecting ACN, it should not replace OC, which remains the gold standard. Keywords: computed tomography colonography, colonography, CT colonography, virtual colonoscopy, colonoscopy, colorectal neoplasm, colorectal cancer, colorectal

  11. Sending family history questionnaires to patients before a colonoscopy improves genetic counseling for hereditary colorectal cancer.

    Science.gov (United States)

    Kessels, Koen; Eisinger, Joey D; Letteboer, Tom G; Offerhaus, G Johan A; Siersema, Peter D; Moons, Leon M G

    2017-06-01

    To investigate whether sending a family history questionnaire to patients prior to undergoing colonoscopy results in an increased availability of family history and better genetic counseling. A questionnaire was mailed to patients before they underwent outpatient colonoscopy at a university hospital in 2013. These patients' additional characteristics and referral for genetic evaluation were retrieved from the electronic medical records. Patients undergoing inpatient coloboscopy, with confirmed hereditary colorectal cancer (CRC) or inflammatory bowel disease were excluded. All study patients from 2010 to 2013 were matched with the database of the genetics department to determine who consulted a geneticist. A total of 6163 patients underwent colonoscopy from 2010 to 2013. Of 1421 who underwent colonoscopy in 2013, 53 (3.7%) consulted a geneticist, while 75 (1.6%) of 4742 patients undergoing colonoscopy between 2010 and 2012 did so (P history was not recorded in the electronic medical records of 393 (40.3%). In 129 (32.8%), family history was obtained from the completed questionnaire. In 2013, 49 (60.5%) out of 81 patients referred for genetic counseling were referred based on their family history. Eight (9.9%) patients were referred based on the completed questionnaire. Screening for hereditary CRC in a population undergoing outpatient colonoscopy with a questionnaire sent by mail resulted in an increased availability of family histories and genetic counseling. © 2017 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  12. Virtual colonoscopy in paediatric patients

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Lopez, Elba Martin; Capunay, Carlos; Vallejos, Javier; Carrascosa, Jorge

    2010-01-01

    Objective: To determine the usefulness of perspective-filet view for polypoid lesions in paediatric patients in comparison with conventional virtual colonoscopy (VC) analysis and optical colonoscopy. Methods: Sixty-one patients (mean age 5 years old) with a previous episode of rectal bleeding were studied using a 16 slices CT scanner. All patients underwent a colonic preparation. Two acquisitions were done in supine and prone positions with slices of 2 mm thickness; increment 1 mm, 30-50 mA; 90-120 kV. In a workstation an experienced radiologist reviewed images twice. The first read was done using the conventional virtual colonoscopy technique with the evaluation of two-dimensional (2D), three-dimensional (3D) and endoscopical images. Later, in a second session, perspective-filet view was used. It shows a 360 deg. unrolled visualization of the inner colon. The presence, size and location of the lesions were determined. A record of the reading time was made. Results: At per patient evaluation the conventional virtual colonoscopy analysis obtained a sensitivity of 86% and a specificity of 98%. The perspective-filet view obtained a sensitivity of 91% and a specificity of 99%. In the evaluation on a per lesion basis the conventional analysis had a sensitivity of 81% and a specificity of 88%. Perspective-filet view, had a sensitivity of 82% and specificity of 90%. The average total reading time using conventional colonoscopy technique was 18 ± 3 min, versus 4 ± 1 min using the perspective-filet view. Conclusion: Virtual colon dissection with perspective-filet view is more time-efficient than conventional virtual colonoscopy evaluation with correct correlation in results.

  13. Cost Effectiveness of Screening Individuals With Cystic Fibrosis for Colorectal Cancer.

    Science.gov (United States)

    Gini, Andrea; Zauber, Ann G; Cenin, Dayna R; Omidvari, Amir-Houshang; Hempstead, Sarah E; Fink, Aliza K; Lowenfels, Albert B; Lansdorp-Vogelaar, Iris

    2018-02-01

    Individuals with cystic fibrosis are at increased risk of colorectal cancer (CRC) compared with the general population, and risk is higher among those who received an organ transplant. We performed a cost-effectiveness analysis to determine optimal CRC screening strategies for patients with cystic fibrosis. We adjusted the existing Microsimulation Screening Analysis-Colon model to reflect increased CRC risk and lower life expectancy in patients with cystic fibrosis. Modeling was performed separately for individuals who never received an organ transplant and patients who had received an organ transplant. We modeled 76 colonoscopy screening strategies that varied the age range and screening interval. The optimal screening strategy was determined based on a willingness to pay threshold of $100,000 per life-year gained. Sensitivity and supplementary analyses were performed, including fecal immunochemical test (FIT) as an alternative test, earlier ages of transplantation, and increased rates of colonoscopy complications, to assess if optimal screening strategies would change. Colonoscopy every 5 years, starting at an age of 40 years, was the optimal colonoscopy strategy for patients with cystic fibrosis who never received an organ transplant; this strategy prevented 79% of deaths from CRC. Among patients with cystic fibrosis who had received an organ transplant, optimal colonoscopy screening should start at an age of 30 or 35 years, depending on the patient's age at time of transplantation. Annual FIT screening was predicted to be cost-effective for patients with cystic fibrosis. However, the level of accuracy of the FIT in this population is not clear. Using a Microsimulation Screening Analysis-Colon model, we found screening of patients with cystic fibrosis for CRC to be cost effective. Because of the higher risk of CRC in these patients, screening should start at an earlier age with a shorter screening interval. The findings of this study (especially those on FIT

  14. Fecal occult blood test for colorectal cancer screening: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    ,800 people were diagnosed with CRC in Ontario and 3,250 died from the disease, making the province's incidence and mortality rate of CRC amongst the highest in the world. THERE ARE TWO GENERAL TYPES OF FOBT THAT ARE CATEGORIZED ACCORDING TO THE ANALYTE DETECTED: guaiac FOBT (gFOBT) and immunochemical FOBT (iFOBT). Blood in the stool is a nonspecific finding but may originate from CRC or larger (>1 cm) polyps (small adenomatous polyps do not tend to bleed). Bleeding from cancers and larger polyps may be intermittent and not always detectable in a single sample. The FOBT thus requires regular testing that consists of collecting specimens from consecutive bowel movements. A positive gFOBT or iFOBT involves a diagnostic workup with colonoscopy to examine the entire colon in order to rule out the presence of cancer or advanced neoplasia. METHODS OF EVIDENCE-BASED ANALYSIS: A literature search was conducted from January 2003 to June 2008 that included OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), The Cochrane Library, and the International Agency for Health Technology Assessment/Centre for Review and Dissemination. Patients at average risk for CRCAll patients must be at least 50 years of ageBiennial FOBT as a screening modality and use of colonoscopy as the reference standardSystematic reviews and randomized controlled trials (RCTs) CRC mortality, overall mortality, sensitivity, specificity, adverse effects Studies involving fewer than 100 patientsStudies that do not report sufficient data for analysis COMPARISONS OF INTEREST: Evidence exists for these comparisons of interest: gFOBT compared with the reference "gold standard" colonoscopy (or double-contrast barium enema where colonoscopy is incomplete or contraindicated)iFOBT compared with the reference gold standard colonoscopy (or DCBE where colonoscopy is incomplete or contraindicated)gFOBT compared with iFOBTThe quality of the

  15. Colorectal Cancer Screening

    OpenAIRE

    Quintero, Enrique; Saito, Yutaka; Hassan, Cessare; Senore, Carlo

    2012-01-01

    Colorectal cancer, which is the leading cancer in Singapore, can be prevented by increased use of screening and polypectomy. A range of screening strategies such as stool-based tests, flexible sigmoidoscopy, colonoscopy and computed tomography colonography are available, each with different strengths and limitations. Primary care physicians should discuss appropriate screening modalities with their patients, tailored to their individual needs. Physicians, patients and the government should wo...

  16. Polyp prevalence at colonoscopy among Nigerians: A prospective ...

    African Journals Online (AJOL)

    Polyp prevalence at colonoscopy among Nigerians: A prospective observational study. ... Materials and Methods: This is a prospective study of all colonoscopy examinations performed at the endoscopy unit of our hospital from January, 2007 to December 2013. The patient demographics, indications for colonoscopy, ...

  17. A novel colonoscopy reporting system enabling quality assurance

    NARCIS (Netherlands)

    van Doorn, Sascha C.; van Vliet, Joost; Fockens, Paul; Dekker, Evelien

    2014-01-01

    The quality of colonoscopy can only be measured if colonoscopy reports include all key quality indicators. In daily practice, reporting is often incomplete and not standardized. This study describes a novel, structured colonoscopy reporting system, which aims to generate standardized and complete

  18. Persistent demographic differences in colorectal cancer screening utilization despite Medicare reimbursement

    Directory of Open Access Journals (Sweden)

    Kreuter William

    2005-03-01

    Full Text Available Abstract Background Colorectal cancer screening is widely recommended, but often under-utilized. In addition, significant demographic differences in screening utilization exist. Insurance coverage may be one factor influencing utilization of colorectal cancer screening tests. Methods We conducted a retrospective analysis of claims for outpatient services for Washington state Medicare beneficiaries in calendar year 2000. We determined the proportion of beneficiaries utilizing screening fecal occult blood tests, flexible sigmoidoscopy, colonoscopy, or double contrast barium enema in the overall population and various demographic subgroups. Multiple logistic regression analysis was used to determine the relative odds of screening in different demographic groups. Results Approximately 9.2% of beneficiaries had fecal occult blood tests, 7.2% had any colonoscopy, flexible sigmoidoscopy, or barium enema (invasive colon tests, and 3.5% had invasive tests for screening indications. Colonoscopy accounted for 41% of all invasive tests for screening indications. Women were more likely to receive fecal occult blood test screening (OR 1.18; 95%CI 1.15, 1.21 and less likely to receive invasive tests for screening indications than men (OR 0.80, 95%CI 0.77, 0.83. Whites were more likely than other racial groups to receive any type of screening. Rural residents were more likely than urban residents to have fecal occult blood tests (OR 1.20, 95%CI 1.17, 1.23 but less likely to receive invasive tests for screening indications (OR 0.89; 95%CI 0.85, 0.93. Conclusion Reported use of fecal occult blood testing remains modest. Overall use of the more invasive tests for screening indications remains essentially unchanged, but there has been a shift toward increased use of screening colonoscopy. Significant demographic differences in screening utilization persist despite consistent insurance coverage.

  19. Screenee perception and health-related quality of life in colorectal cancer screening: a review.

    Science.gov (United States)

    Pizzo, Elena; Pezzoli, Alessandro; Stockbrugger, Reinhold; Bracci, Enrico; Vagnoni, Emidia; Gullini, Sergio

    2011-01-01

    Screening for colorectal cancer (CRC) has become established to varying degrees in several Western countries for the past 30 years. Because of its effectiveness, screening has been adopted or is planned in a number of other countries. In most countries, the screening method (e.g., fecal occult blood test [FOBT], sigmoidoscopy) is followed by colonoscopy, for verification. In other countries (e.g., United States, Germany), colonoscopy is the preferred first-line investigation method. However, because colonoscopy is considered to be invasive, might be poorly tolerated, and can be associated with complications, the idea of adopting colonoscopy as the primary screening method suffers. Negative effects of screening methods can reduce participation in programs and thereby negate the desired effect on individual and societal health. At present, there is no generally accepted method either to assess the perception and satisfaction of patients screened or the outcome of the screening procedures in CRC. In this review, we discuss the past development and present availability of instruments to measure health-related quality of life (HRQoL), the scarce studies in which such instruments have been used in screening campaigns, and the findings. We suggest the creation of a specific instrument for the assessment of HRQoL in CRC screening. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  20. Cancer risk awareness and screening uptake in individuals at higher risk for colon cancer: a cross-sectional study.

    Science.gov (United States)

    Salimzadeh, Hamideh; Bishehsari, Faraz; Delavari, Alireza; Barzin, Gilda; Amani, Mohammad; Majidi, Azam; Sadjadi, Alireza; Malekzadeh, Reza

    2016-12-20

    We aimed to measure cancer knowledge and feasibility of a screening colonoscopy among a cohort of individuals at higher risk of colon cancer. This study was conducted as part of an ongoing screening cohort, in which first degree relatives (FDRs) of patients with colon cancer are invited to participate in a free of charge screening colonoscopy. We enrolled 1017 FDRs in the study between 2013 and 2014 measuring their data on demographics, cancer knowledge and colonoscopy uptake. A p value of aware of their increased risk for cancer, near 35.0% had ever heard about colonoscopy with 22% aware of the correct age to start screening. Comparing cancer knowledge of FDRs at high risk versus those at moderate risk, we recorded non-significant differences (p>0.05). Almost two-thirds of FDRs expressed willingness to undergo a colonoscopy and 49.2% completed the procedure, of which 12.8% had advanced neoplasm. Our data indicated that remarkable numbers of FDRs were not still informed of their cancer risk or never received a physician recommendation for screening. The desirable uptake at first invitation, which would be higher over successive invitations, supports the feasibility of a family-based recruitment approach for early screening. This has promising implications to introduce targeted screening colonoscopy into the healthcare system in Iran and other developing nations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Small bowel obstruction complicating colonoscopy: a case report

    Directory of Open Access Journals (Sweden)

    Hunter Iain A

    2008-05-01

    Full Text Available Abstract Introduction This report describes a rare complication of colonoscopy and reviews the literature with regard to other rare causes of acute abdominal presentations following colonoscopy. Case presentation After a therapeutic colonoscopy a 60-year-old woman developed an acute abdomen. At laparotomy she was discovered to have small bowel obstruction secondary to incarceration through a congenital band adhesion. Conclusion Although there is no practical way in which such rare complications can be predicted, this case report emphasises the wide array of pathologies that can result in acute abdominal symptoms following colonoscopy.

  2. Transmural Colonic Infarction after Routine Colonoscopy in a Young Patient without Risk Factors

    Directory of Open Access Journals (Sweden)

    Maurizio Zizzo

    2016-09-01

    Full Text Available Colonoscopy is one of the most widely used procedures in medical practice for the diagnosis and treatment of many benign and malignant diseases of the colorectal tract. Colonscopy has become the reference procedure for screening and surveillance of colorectal cancer. The overall rate of adverse events is estimated to be about 2.8 per 1,000 procedures, while complications requiring hospitalization are about 1.9 per 1,000 colonoscopies. Mortality from all causes and colonoscopy-specific mortality are estimated to be 0.07 and 0.007%, respectively. An exceptional fearsome postcolonoscopy complication is colon ischemia (CI; only few cases have been reported worldwide. We present the case of a 43-year-old woman who presented to the emergency department complaining of abdominal pain; fever and rectal bleeding appeared 12 h after a voluntary ‘screening’ colonoscopy. She had no risk factors for CI. Her laboratory tests showed alterations in inflammatory markers and a computed tomography scan showed a circumferential thickening in the left colon and free fluid in the abdomen. After 12 h of observation and conservative therapy, the clinical state of the patient worsened with the rising of signs of peritonitis. Laparoscopy showed that colon infarction extended from the distal third of the transverse colon to the proximal rectum. Laparotomy, resection of the pathological colon and terminal colostomy were performed. The specimen examined confirmed an extended ischemic colitis and transmural infarction on the antimesocolic side, in the absence of a vasculitis. The patient underwent recanalization after 8 months. CI after colonoscopy is a rare and alarming complication that must be known and taken into account in the differential diagnosis of symptomatic cases after colonoscopy, particularly in patients with known risk factors. The diagnosis is mainly based on clinical data, imaging and especially endoscopy. Treatment is almost always conservative but, in

  3. Colonoscopy and Colorectal Cancer Screening in Adults with Intellectual and Developmental Disabilities: Review of a Series of Cases and Recommendations for Examination

    Science.gov (United States)

    Fischer, Leonard S.; Becker, Andrew; Paraguya, Maria; Chukwu, Cecilia

    2012-01-01

    Adults with intellectual and developmental disabilities (IDD) frequently have comorbidities that might interfere with colonoscopy preparation and examination. In this article, the authors review their experience with colonoscopies performed from 2002 through 2010 on adults with IDD at a state institution to evaluate quality and safety of…

  4. Colorectal Cancer Screening (PDQ®)—Health Professional Version

    Science.gov (United States)

    Colorectal cancer (CRC) screening reduces CRC mortality; some screening modalities also reduce CRC incidence. Get detailed information about CRC screening tests (e.g., fecal occult blood test, sigmoidoscopy, colonoscopy, stool DNA) including potential benefits and harms in this clinician summary.

  5. Colorectal cancer screening

    OpenAIRE

    Plumb, A. A.; Halligan, S.

    2015-01-01

    Colorectal cancer is a major public health burden worldwide. There is clear-cut evidence that screening will reduce colorectal cancer mortality and the only contentious issue is which screening tool to use. Most evidence points towards screening with fecal occult blood testing. The immunochemical fecal occult blood tests have a higher sensitivity than the guaiac-based tests. In addition, their automation and haemoglobin quantification allows a threshold for colonoscopy to be selected that can...

  6. Accuracy of colonoscopy in localizing colonic cancer.

    Science.gov (United States)

    Stanciu, C; Trifan, Anca; Khder, Saad Alla

    2007-01-01

    It is important to establish the precise localization of colonic cancer preoperatively; while colonoscopy is regarded as the diagnostic gold standard for colorectal cancer, its ability to localize the tumor is less reliable. To define the accuracy of colonoscopy in identifying the location of colonic cancer. All of the patients who had a colorectal cancer diagnosed by colonoscopy at the Institute of Gastroenterology and Hepatology, Iaşi and subsequently received a surgical intervention at three teaching hospitals in Iaşi, between January 2001 and December 2005, were included in this study. Endoscopic records and operative notes were carefully reviewed, and tumor localization was recorded. There were 161 patients (89 men, 72 women, aged 61.3 +/- 12.8 years) who underwent conventional surgery for colon cancer detected by colonoscopy during the study period. Twenty-two patients (13.66%) had erroneous colonoscopic localization of the tumors. The overall accuracy of preoperative colonoscopic localization was 87.58%. Colonoscopy is an accurate, reliable method for locating colon cancer, although additional techniques (i.e., endoscopic tattooing) should be performed at least for small lesions.

  7. Virtual CT-colonoscopy resources in large intestine neoplasia

    Directory of Open Access Journals (Sweden)

    Chalyk Yu.V.

    2011-12-01

    Full Text Available The research goal is to state possibility of virtual colonoscopy and to determine the localization and nature of neoplasms in the large intestine. Materials and methods: 38 patients have been examined by the method of virtual colonoscopy. The preceding stage of diagnosis by total fibrocolonoscopy has not been a success. Results: Virtual colonoscopy has been performed in 94.7% of patients. The same tumors have been identified in the proximal colon, direct examination of which has not been possible. Conclusion: Virtual colonoscopy is the method of choice for topical diagnosis of tumors of the colon

  8. Colonic gas explosion during therapeutic colonoscopy with electrocautery

    Science.gov (United States)

    Ladas, Spiros D; Karamanolis, George; Ben-Soussan, Emmanuel

    2007-01-01

    Therapeutic colonoscopy with electrocautery is widely used around the world. Adequate colonic cleansing is considered a crucial factor for the safety of this procedure. Colonic gas explosion, although rare, is one of the most frightening iatrogenic complications during colonoscopy with electrocautery. This complication is the result of an accumulation of colonic gases to explosive concentrations, but may be prevented by meticulous bowel preparation. The purpose of this review is to discuss the indications and the types of bowel preparations for therapeutic colonoscopy, and to contribute recommendations for the adequate bowel preparation for colonoscopy with electrocautery. PMID:17879396

  9. The utility of Google Trends data to examine interest in cancer screening.

    Science.gov (United States)

    Schootman, M; Toor, A; Cavazos-Rehg, P; Jeffe, D B; McQueen, A; Eberth, J; Davidson, N O

    2015-06-08

    We examined the utility of January 2004 to April 2014 Google Trends data from information searches for cancer screenings and preparations as a complement to population screening data, which are traditionally estimated through costly population-level surveys. State-level data across the USA. Persons who searched for terms related to cancer screening using Google, and persons who participated in the Behavioral Risk Factor Surveillance System (BRFSS). (1) State-level Google Trends data, providing relative search volume (RSV) data scaled to the highest search proportion per week (RSV100) for search terms over time since 2004 and across different geographical locations. (2) RSV of new screening tests, free/low-cost screening for breast and colorectal cancer, and new preparations for colonoscopy (Prepopik). (3) State-level breast, cervical, colorectal and prostate cancer screening rates. Correlations between Google Trends and BRFSS data ranged from 0.55 for ever having had a colonoscopy to 0.14 for having a Pap smear within the past 3 years. Free/low-cost mammography and colonoscopy showed higher RSV during their respective cancer awareness months. RSV for Miralax remained stable, while interest in Prepopik increased over time. RSV for lung cancer screening, virtual colonoscopy and three-dimensional mammography was low. Google Trends data provides enormous scientific possibilities, but are not a suitable substitute for, but may complement, traditional data collection and analysis about cancer screening and related interests. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Impact of cap-assisted colonoscopy on the learning curve and quality in colonoscopy: a randomized controlled trial.

    Science.gov (United States)

    Tang, Zhouwen; Zhang, Daniel S; Thrift, Aaron P; Patel, Kalpesh K

    2018-03-01

    Colonoscopy competency assessment in trainees traditionally has been informal. Comprehensive metrics such as the Assessment of Competency in Endoscopy (ACE) tool suggest that competency thresholds are higher than assumed. Cap-assisted colonoscopy (CAC) may improve competency, but data regarding novice trainees are lacking. We compared CAC versus standard colonoscopy (SC) performed by novice trainees in a randomized controlled trial. All colonoscopies performed by 3 gastroenterology fellows without prior experience were eligible for the study. Exclusion criteria included patient age 90 years, pregnancy, prior colon resection, diverticulitis, colon obstruction, severe hematochezia, referral for EMR, or a procedure done without patient sedation. Patients were randomized to either CAC or SC in a 1:1 fashion. The primary outcome was the independent cecal intubation rate (ICIR). Secondary outcomes were cecal intubation time, polyp detection rate, polyp miss rate, adenoma detection rate, ACE tool scores, and cumulative summation learning curves. A total of 203 colonoscopies were analyzed, 101 in CAC and 102 in SC. CAC resulted in a significantly higher cecal intubation rate, at 79.2% in CAC compared with 66.7% in SC (P = .04). Overall cecal intubation time was significantly shorter at 13.7 minutes for CAC versus 16.5 minutes for SC (P =.02). Cecal intubation time in the case of successful independent fellow intubation was not significantly different between CAC and SC (11.6 minutes vs 12.7 minutes; P = .29). Overall ACE tool motor and cognitive scores were higher with CAC. Learning curves for ICIR approached the competency threshold earlier with cap use but reached competency for only 1 fellow. The polyp detection rate, polyp miss rate, and adenoma detection rate were not significantly different between groups. CAC resulted in significant improvement in ICIR, overall ACE tool scores, and trend toward competency on learning curves when compared with SC in colonoscopy

  11. Celebrity endorsements of cancer screening.

    Science.gov (United States)

    Larson, Robin J; Woloshin, Steven; Schwartz, Lisa M; Welch, H Gilbert

    2005-05-04

    Celebrities often promote cancer screening by relating personal anecdotes about their own diagnosis or that of a loved one. We used data obtained from a random-digit dialing survey conducted in the United States from December 2001 through July 2002 to examine the extent to which adults of screening age without a history of cancer had seen or heard or been influenced by celebrity endorsements of screening mammography, prostate-specific antigen (PSA) testing, or sigmoidoscopy or colonoscopy. The survey response rate was 72% among those known to be eligible and 51% among potentially eligible people accounting for those who could not be contacted. A total of 360 women aged 40 years or older and 140 men aged 50 years or older participated in the survey. Most respondents reported they "had seen or heard a celebrity talk about" mammography (73% of women aged 40 years or older), PSA testing (63% of men aged 50 years or older), or sigmoidoscopy or colonoscopy (52% of adults aged 50 years or older). At least one-fourth of respondents who had seen or heard a celebrity endorsement said that the endorsement made them more likely to undergo mammography (25%), PSA testing (31%), or sigmoidoscopy or colonoscopy (37%).

  12. Advances in CRC Prevention: Screening and Surveillance.

    Science.gov (United States)

    Dekker, Evelien; Rex, Douglas K

    2018-05-01

    Colorectal cancer (CRC) is among the most commonly diagnosed cancers and causes of death from cancer across the world. CRC can, however, be detected in asymptomatic patients at a curable stage, and several studies have shown lower mortality among patients who undergo screening compared with those who do not. Using colonoscopy in CRC screening also results in the detection of precancerous polyps that can be directly removed during the procedure, thereby reducing the incidence of cancer. In the past decade, convincing evidence has appeared that the effectiveness of colonoscopy as CRC prevention tool is associated with the quality of the procedure. This review aims to provide an up-to-date overview of recent efforts to improve colonoscopy effectiveness by enhancing detection and improving the completeness and safety of resection of colorectal lesions. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  13. Differences between husbands and wives in colonoscopy use: Results from a national sample of married couples.

    Science.gov (United States)

    Kotwal, Ashwin A; Lauderdale, Diane S; Waite, Linda J; Dale, William

    2016-07-01

    Marriage is linked to improved colorectal cancer-related health, likely in part through preventive health behaviors, but it is unclear what role spouses play in colorectal cancer screening. We therefore determine whether self-reported colonoscopy rates are correlated within married couples and the characteristics of spouses associated with colonoscopy use in each partner. We use US nationally-representative 2010 data which includes 804 male-female married couples drawn from a total sample of 3137 community-dwelling adults aged 55-90years old. Using a logistic regression model in the full sample (N=3137), we first find married men have higher adjusted colonoscopy rates than unmarried men (61% versus 52%, p=0.023), but women's rates do not differ by marital status. In the couples' sample (N=804 couples), we use a bivariate probit regression model to estimate multiple regression equations for the two spouses simultaneously as a function of individual and spousal covariates, as well as the adjusted correlation within couples. We find that individuals are nearly twice as likely to receive a colonoscopy if their spouse recently has had one (OR=1.94, 95% CI: 1.39, 2.67, pvs 51%, p=0.020); 2) more highly educated (72% vs 51%, p=0.020), and 3) viewed as more supportive (65% vs 52%, p=0.020). Recognizing the role of marital status, relationship quality, and spousal characteristics on colonoscopy uptake, particularly in men, could help physicians increase guideline adherence. Copyright © 2016. Published by Elsevier Inc.

  14. Motion-Computerized Tomographic Colography is a Better Method for Screening for Polyps: Arguments for the Motion

    Directory of Open Access Journals (Sweden)

    Benoit C Pineau

    2003-01-01

    Full Text Available Colorectal cancer is an important public health problem that is amenable to prevention and early treatment. Traditional screening techniques - fecal occult blood testing, flexible sigmoidoscopy, barium enema and colonoscopy - each have limitations in terms of diagnostic accuracy, cost and/or patient acceptability. Compliance with recommendations for screening has been poor, in part, because of negative perceptions about the available modalities. Virtual colonoscopy, or computerized tomographic colography, is a minimally invasive technique that safely evaluates the entire colon and does not require sedation. Thorough cleansing as well as immobilization and air insufflation of the colon is crucial to a successful examination. Sensitivity and specificity rates are reasonable, compared with conventional colonoscopy, and it has been shown that the latter technique can be averted in over two-thirds of cases, with few false-negative examinations. Most patients find virtual colonoscopy more acceptable than the conventional technique, and would prefer it if a repeat procedure were warranted. An economic analysis that found that computerized tomographic colography was less cost effective than conventional colonoscopy did not consider the indirect costs of the latter, which is an important limitation. Virtual colonoscopy is a novel radiological technique that may revolutionize screening for colorectal cancer.

  15. Acculturation and cancer screening among Asian Americans: role of health insurance and having a regular physician.

    Science.gov (United States)

    Lee, Sunmin; Chen, Lu; Jung, Mary Y; Baezconde-Garbanati, Lourdes; Juon, Hee-Soon

    2014-04-01

    Cancer is the leading cause of death among Asian Americans, but screening rates are significantly lower in Asians than in non-Hispanic Whites. This study examined associations between acculturation and three types of cancer screening (colorectal, cervical, and breast), focusing on the role of health insurance and having a regular physician. A cross-sectional study of 851 Chinese, Korean, and Vietnamese Americans was conducted in Maryland. Acculturation was measured using an abridged version of the Suinn-Lew Asian Self-Identity Acculturation Scale, acculturation clusters, language preference, length of residency in the US, and age at arrival. Age, health insurance, regular physician, gender, ethnicity, income, marital status, and health status were adjusted in the multivariate analysis. Logistic regression analysis showed that various measures of acculturation were positively associated with the odds of having all cancer screenings. Those lived for more than 20 years in the US were about 2-4 times [odds ratio (OR) and 95 % confidence interval (CI) colorectal: 2.41 (1.52-3.82); cervical: 1.79 (1.07-3.01); and breast: 2.11 (1.25-3.57)] more likely than those who lived for less than 10 years to have had cancer screening. When health insurance and having a regular physician were adjusted, the associations between length of residency and colorectal cancer [OR 1.72 (1.05-2.81)] was reduced and the association between length of residency and cervical and breast cancer became no longer significant. Findings from this study provide a robust and comprehensive picture of AA cancer screening behavior. They will provide helpful information on future target groups for promoting cancer screening.

  16. Improving the Yield of Histological Sampling in Patients With Suspected Colorectal Cancer During Colonoscopy by Introducing a Colonoscopy Quality Assurance Program.

    Science.gov (United States)

    Gado, Ahmed; Ebeid, Basel; Abdelmohsen, Aida; Axon, Anthony

    2011-08-01

    Masses discovered by clinical examination, imaging or endoscopic studies that are suspicious for malignancy typically require biopsy confirmation before treatment is initiated. Biopsy specimens may fail to yield a definitive diagnosis if the lesion is extensively ulcerated or otherwise necrotic and viable tumor tissue is not obtained on sampling. The diagnostic yield is improved when multiple biopsy samples (BSs) are taken. A colonoscopy quality-assurance program (CQAP) was instituted in 2003 in our institution. The aim of this study was to determine the effect of instituting a CQAP on the yield of histological sampling in patients with suspected colorectal cancer (CRC) during colonoscopy. Initial assessment of colonoscopy practice was performed in 2003. A total of five patients with suspected CRC during colonoscopy were documented in 2003. BSs confirmed CRC in three (60%) patients and were nondiagnostic in two (40%). A quality-improvement process was instituted which required a minimum six BSs with adequate size of the samples from any suspected CRC during colonoscopy. A total of 37 patients for the period 2004-2010 were prospectively assessed. The diagnosis of CRC was confirmed with histological examination of BSs obtained during colonoscopy in 63% of patients in 2004, 60% in 2005, 50% in 2006, 67% in 2007, 100% in 2008, 67% in 2009 and 100% in 2010. The yield of histological sampling increased significantly ( p quality assurance and improvement program increased the yield of histological sampling in patients with suspected CRC during colonoscopy.

  17. The comparison of CT virtual colonoscopy with video colonoscopy (the detection of simulated polyps in pig colon)

    International Nuclear Information System (INIS)

    Tang Wen; Gong Jianping; Gao Zhixin; Lu Zhian

    2000-01-01

    Objective: To assess the value of CT virtual colonoscopy for the detection of simulated polyps in pig colon. Methods: Injecting the smelted wax under the mucosa to simulate the polyps in pig colon, then detected by video colonoscopy and scanned by helical CT. The images were obtained with collimation 3 mm, 5 mm, 10 mm and with the table pitch 1 and 2. All images were reconstructed at 1 mm intervals. Results: The shapes were depicted as follows: those greater than 10 mm in diameter polyps were clearly depicted. 5-9 mm in diameter polyps were faintly depicted. Those smaller than 5 mm in diameter were depicted difficulty. The details depicted: polyps larger than 10 mm in diameter and 5-9 mm in diameter were clearly depicted and that smaller than 5 mm in diameter were depicted difficulty. The images quality lowered with the increasing collimation and pitch. Conclusion: CT virtual colonoscopy is a non-invasive diagnostic technique. It can show the inner wall of colon as same as video colonoscopy does, and is a good alternative in clinical application

  18. Factors affecting successful colonoscopy procedures: Single-center experience.

    Science.gov (United States)

    Kozan, Ramazan; Yılmaz, Tonguç Utku; Baştuğral, Uygar; Kerimoğlu, Umut; Yavuz, Yücel

    2018-01-01

    Colonoscopy is a gold standard procedure for several colon pathologies. Successful colonoscopy means demonstration of the ileocecal valve and determination of colon polyps. Here we aimed to evaluate our colonoscopy success and results. This retrospective descriptive study was performed in İstanbul Eren hospital endoscopy unit between 2012 and 2015. Colonoscopy results and patient demographics were obtained from the hospital database. All colonoscopy procedures were performed under general anesthesia and after full bowel preparation. In all, 870 patients were included to the study. We reached to the cecum in 850 (97.8%) patients. We were unable to reach the cecum in patients who were old and obese and those with previous lower abdominal operations. Angulation, inability to move forward, and tortuous colon were the reasons for inability to reach the cecum. Total 203 polyp samplings were performed in 139 patients. We performed 1, 2, and 3 polypectomies in 97, 28, and 10 patients, respectively. There were 29 (3.3%) colorectal cancers in our series. There was no mortality or morbidity in our study. General anesthesia and full bowel preparation may be the reason for increased success of colonoscopy. Increased experience and patient-endoscopist cooperation increased the rate of cecum access and polyp resection and decreased the complication rate.

  19. Characteristics of right-sided colonic neoplasia and colonoscopy barriers limiting their early detection and prognosis: a review of the literature.

    Science.gov (United States)

    Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat

    2018-06-05

    Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.

  20. Organized colorectal cancer screening in Serbia - the first round within 2013-2014.

    Science.gov (United States)

    Banković Lazarević, Dušica; Krivokapić, Zoran; Barišić, Goran; Jovanović, Verica; Ilić, Dragan; Veljković, Marko

    2016-04-01

    The National Organized Colorectal Cancer Screening Program was conducted in the Republic of Serbia during 2013-2014 covering the population of both genders, aged 50 to 74 years, in 28 municipalities out of 180, with the target population of 651,445 people. This organized colorectal cancer screening aims to reduce mortality from colorectal cancer in the target population. The aim of this study was to show the results of organized screening for colorectal cancer during the first biannual round in Serbia. General practitioners from the primary health centers, invited target population by letters and by phone to perform immunochemical fecal occult blood test. Persons with a positive test results were referred to the colonoscopy. The database of health insurance and other citizens of the target population was used for invitation for screening in primary health centers. Descriptive statistical analysis of the results in organized colorectal cancer screening in the first round was performed for the key screening indicators. In the first round, a total of 99,592 persons were invited. The participation rate was 62.5%. Colonoscopy was performed in 1,554 persons. Adenomas were found in 586 persons (0.9% of all the tested), e.g. 37.7 % of all colonoscopied. In 129 persons colorectal cancer was diagnosed (0.2% of all the tested), e.g. 8.3% of all the colonoscopied. In the left half of the colon (rectum, sigmoid and descending colon) there were 70.4% diagnosed polyps and 77.3% carcinomas, while 29.6% of polyps and 22.7% carcinomas were found in the proximal parts of the colon. In the first round of the organized colorectal cancer screening in Serbia the participation rate of the targeted population was high and gave encouraging result. It was expected that in the forthcoming rounds even higher coverage of the target population would be accomplished. A positive predictive value of the completed colonoscopies showed that further work on observing the stages of diagnosed adenomas

  1. Quality assurance as an integrated part of the electronic medical record - a prototype applied for colonoscopy.

    Science.gov (United States)

    Hoff, Geir; Ottestad, Per Marcus; Skafløtten, Stein Roger; Bretthauer, Michael; Moritz, Volker

    2009-01-01

    Electronic medical records (EMRs) have not developed much beyond the days of typewritten journals when it comes to facilitating extraction of data for quality assurance (QA) and improvement of health-care performance. Based on 5 years' experience from the Norwegian Gastronet QA programme, we have developed a highly QA-profiled EMR for colonoscopy. We used a three-tier solution (client, server and database) written in the Java programming language using a number of open-source libraries. QA principles from the Norwegian paper-based Gastronet QA programme formed the basis for development of the ColoReg software. ColoReg is developed primarily for colonoscopy reporting in a screening trial, but may be used in routine clinical work. The QA module in ColoReg is well suited for intervention towards suboptimal performance in both settings. We have developed user-friendly software dominated by clickable boxes and curtain menus reducing free text to a minimum. The software gives warnings when illogical registrations are entered and reasons have to be given for divergence from software recommendations for work-up and surveillance. At any time, defined performance quality parameters are readily accessible in tabular form with the named, logged-in endoscopist being compared with all other anonymized endoscopists in the database. The ColoReg software is developed for use in an international, multicentre trial on colonoscopy screening. It is user-friendly and secures continuous QA of the endoscopist's performance. The principles used are applicable to development of EMRs in general.

  2. Does gender discrimination impact regular mammography screening? Findings from the race differences in screening mammography study.

    Science.gov (United States)

    Dailey, Amy B; Kasl, Stanislav V; Jones, Beth A

    2008-03-01

    ABSTRACT Objective: To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. African American and white women (1451) aged 40-79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of > or =$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women.

  3. The Impact of a Population-Based Screening Program on Income- and Immigration-Related Disparities in Colorectal Cancer Screening.

    Science.gov (United States)

    Kiran, Tara; Glazier, Richard H; Moineddin, Rahim; Gu, Sumei; Wilton, Andrew S; Paszat, Lawrence

    2017-09-01

    Background: A population-based program promoting the Fecal Occult Blood Test (FOBT) for colorectal cancer screening was introduced in 2008 in Ontario, Canada, where opportunistic screening with colonoscopy had been increasing in frequency. We evaluated the impact of the program on income and immigration-related disparities in screening. Methods: We used linked administrative data to calculate colorectal cancer screening rates for eligible Ontarians in each year between 2001/02 ( n = 2,852,619) and 2013/14 ( n = 4,139,304). We quantified disparities using an "inequality ratio" of screening rates in the most disadvantaged group relative to the most advantaged group. We performed segmented logistic regression analyses stratified by screening modality and adjusted for age, sex, rurality, comorbidity, and morbidity. Results: Between 2001/02 and 2013/14, the income and immigration inequality ratios narrowed from 0.74 to 0.80 and 0.55 to 0.69, respectively. Before the screening program, the income inequality ratio was widening by 1% per year (95% CI 1% to 1%); in the year it was introduced, it narrowed by 4% (95% CI 2% to 7%) and in the years following, it remained stable [0% decrease (95% CI 1% decrease to 0% decrease) per year]. Results were similar for immigration-related disparities. After program introduction, disparities in receiving FOBT were narrowing at a faster rate while disparities in receiving colonoscopy were widening at a slower rate. Conclusions: Introduction of a population-based screening program promoting FOBT for colorectal cancer was associated with only modest improvements in immigration and income-related disparities. Impact: Reducing immigration and income-related disparities should be a focus for future research and policy work. Disparities in Ontario seem to be driven by a higher uptake of colonoscopy among more advantaged groups. Cancer Epidemiol Biomarkers Prev; 26(9); 1401-10. ©2017 AACR . ©2017 American Association for Cancer Research.

  4. Difference in F-18 FDG uptake after esophago gastroduodenoscopy and colonoscopy in healthy sedated subjects

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong Ryool; Chang, Woo Jin; Bae, Seung Il; Song, In Wook; Bong, Jin Gu; Jeong, Hye Yeon; Park, So Young; Bae, Jeong Yup; Yoon, Hyun Dae [Raphael Hospital, Daegu (Korea, Republic of); Seo, Ji Hyoung [Dept. of Nuclear MedicineFatima Hospital, Daegu (Korea, Republic of)

    2017-09-15

    We aimed to evaluate the difference in fluorodeoxyglucose (FDG) uptake in sedated healthy subjects after they underwent esophagogastroduodenoscopy (EGD) and colonoscopy procedures. The endoscopy group (n = 29) included healthy subjects who underwent screening via F-18 FDG positron emission tomography/computed tomography (PET/CT) after an EGD and/or colonoscopy under sedation on the same day. The control group (n = 35) included healthy subjects who underwent screening via PET/CT only. FDG uptake in the tongue, uvula, epiglottis, vocal cords, esophagus, stomach, duodenum, liver, cecum, colon, anus, and muscle were compared between the two groups. Maximum standardized uptake value (SUVmax) in the tongue, pharynx, larynx, and esophagus did not significantly differ between the endoscopy and control groups. In contrast, mean SUVmax in the whole stomach was 18 % higher in the endoscopy group than in the control group (SUVmax: 2.96 vs. 2.51, P = 0.010). In the lower gastrointestinal track, SUVmax from the cecum to the rectum was not significantly different between the two groups, whereas SUVmax in the anus was 20 % higher in the endoscopy group than in the control group (SUVmax: 4.21 vs. 3.50, P = 0.002). SUVmax in the liver and muscle was not significantly different between the two groups. Mean volume of the stomach and mean cross section of the colon was significantly higher in the endoscopy group than in the control group (stomach: 313.28 cm{sup 3} vs. 209.93 cm{sup 3}, P < 0.001, colon: 8.82 cm{sup 2} vs. 5.98 cm{sup 2}, P = 0.001). EGD and colonoscopy under sedation does not lead to significant differences in SUVmax in most parts of the body. Only gastric FDG uptake in the EGD subjects and anal FDG uptake in the colonoscopy subjects was higher than uptake in those regions in the control subjects.

  5. A novel summary report of colonoscopy: timeline visualization providing meaningful colonoscopy video information.

    Science.gov (United States)

    Cho, Minwoo; Kim, Jee Hyun; Kong, Hyoun Joong; Hong, Kyoung Sup; Kim, Sungwan

    2018-05-01

    The colonoscopy adenoma detection rate depends largely on physician experience and skill, and overlooked colorectal adenomas could develop into cancer. This study assessed a system that detects polyps and summarizes meaningful information from colonoscopy videos. One hundred thirteen consecutive patients had colonoscopy videos prospectively recorded at the Seoul National University Hospital. Informative video frames were extracted using a MATLAB support vector machine (SVM) model and classified as bleeding, polypectomy, tool, residue, thin wrinkle, folded wrinkle, or common. Thin wrinkle, folded wrinkle, and common frames were reanalyzed using SVM for polyp detection. The SVM model was applied hierarchically for effective classification and optimization of the SVM. The mean classification accuracy according to type was over 93%; sensitivity was over 87%. The mean sensitivity for polyp detection was 82.1%, and the positive predicted value (PPV) was 39.3%. Polyps detected using the system were larger (6.3 ± 6.4 vs. 4.9 ± 2.5 mm; P = 0.003) with a more pedunculated morphology (Yamada type III, 10.2 vs. 0%; P < 0.001; Yamada type IV, 2.8 vs. 0%; P < 0.001) than polyps missed by the system. There were no statistically significant differences in polyp distribution or histology between the groups. Informative frames and suspected polyps were presented on a timeline. This summary was evaluated using the system usability scale questionnaire; 89.3% of participants expressed positive opinions. We developed and verified a system to extract meaningful information from colonoscopy videos. Although further improvement and validation of the system is needed, the proposed system is useful for physicians and patients.

  6. Evaluation of Colonoscopy Skills – How Well Are We Doing?

    Directory of Open Access Journals (Sweden)

    Rachid Mohamed

    2011-01-01

    Full Text Available Colonoscopy is a complex task that requires the interplay of motor and cognitive skill sets. Traditional teaching of colonoscopy involves observation in an apprenticeship model. Individual trainees vary in their rate of their skill acquisition, and this trial-and-error method often results in frustration and anxiety for both the educator and the learner. Currently, there are no guidelines to determine the competence or proficiency of an individual for colonoscopy. Furthermore, there is a paucity of information regarding formal training curricula for colonoscopy skills acquisition. The present study investigated a formal and validated educational framework for colonoscopy teaching and compared it with the traditional apprenticeship model in first-year trainees.

  7. Prospective comparison of double contrast barium enema plus flexible sigmoidoscopy v colonoscopy in rectal bleeding: barium enema v colonoscopy in rectal bleeding.

    OpenAIRE

    Irvine, E J; O'Connor, J; Frost, R A; Shorvon, P; Somers, S; Stevenson, G W; Hunt, R H

    1988-01-01

    Rectal bleeding often heralds serious colonic disease. The literature suggests that colonoscopy is superior to barium enema plus sigmoidoscopy, although no good comparative studies exist. Seventy one patients with overt rectal bleeding had prospectively flexible sigmoidoscopy, double contrast barium enema and colonoscopy completed independently. Against the gold standard, the sensitivity and specificity of colonoscopy were 0.69 and 0.78 respectively for a spectrum of colonic lesions, while fo...

  8. Colorectal cancer screening: results of a 5-year program in asymptomatic subjects at increased risk.

    Science.gov (United States)

    Pezzoli, A; Matarese, V; Rubini, M; Simoni, M; Caravelli, G C; Stockbrugger, R; Cifalà, V; Boccia, S; Feo, C; Simone, L; Trevisani, L; Liboni, A; Gullini, S

    2007-01-01

    The province of Ferrara has one of the highest incidences of colorectal cancer (CRC) in Italy. In January 2000, we set up a colonoscopy screening program focussing on first-degree relatives of CRC patients. We now report the results 5 years after the beginning of the project. SCREENEES AND METHODS: In October 1999, we started a campaign stressing the usefulness of colonoscopy for the first-degree relatives of CRC patients. Subjects included in the screening program were aged between 45 and 75 years with at least one first-degree relative affected by CRC. They were invited to an interview where a physician suggested colonoscopy as a screening option. In 5 years, 776 subjects were interviewed and 733 (94.4%) agreed to an endoscopic examination (M/F:375/401; mean age 55 years): 562 colonoscopies were performed. Adenomas and cancers were found in 122 (21.7%) and 12 (2.1%) subjects, respectively. Histological examination in 181 persons with lesions (32.8%) showed (most serious lesion quoted) 47 hyperplastic polyps (26% of all lesions), 2 serrated adenomas (1.1%), 68 tubular adenomas (48%), 24 tubulovillous adenomas (13.3%), 9 adenomas with high grade dysplasia (5%) and 12 adenocarcinomas (6.6%). The majority of the cancers were at an early stage (8 Dukes A and 3 Dukes B). Sedation was used in only 42 colonoscopies (7.5%). A colonoscopy-based screening in this selected high-risk population is feasible. Even without sedation subjects readily agreed to the endoscopic procedure. We identified a significant number of advanced neoplasms and cancers at an early stage suggesting that this could be a useful tool in early identification of CRC.

  9. Automatic and unbiased assessment of competence in colonoscopy

    DEFF Research Database (Denmark)

    Preisler, Louise; Svendsen, Morten Bo Søndergaard; Søndergaard, Bo

    2016-01-01

    is the first clinical descriptive report of a novel colonoscopy assessment tool based on Magnetic Endoscopic Imaging (MEI) data and the aim was to gather validity evidence based on the data collected using the "Colonoscopy Progression Score" (CoPS). Methods: We recorded 137 colonoscopy procedures performed...... sources of validity evidence were explored: response process (data collection), internal structure (reliability), relationship to other variables (i. e. operator experience), and consequences of testing (pass/fail). Results: Identical set-ups at all three locations ensured uniform data collection...

  10. Peri-colonic haematoma following routine colonoscopy

    OpenAIRE

    Felicity Page; Olfunso Adedeji

    2016-01-01

    Introduction: We present a case of an extra-luminal haematoma following routine colonoscopy. This case highlights an uncommon but potentially life threatening complication in which there is little published literature to date. Presentation of case: A 73 year old male presented with abdominal pain and a reduction in haemoglobin following an uneventful colonoscopy. The imaging had been required as part of colorectal cancer follow up. Initial differential diagnosis included colonic perforatio...

  11. Tamizaje del cáncer colorrectal Screening for colorectal cancer

    Directory of Open Access Journals (Sweden)

    2002-10-01

    Full Text Available This piece summarizes new recommendations from the Preventive Services Task Force of the United States of America concerning screening for colorectal cancer (CRC. These recommendations update and replace ones that were issued in 1996. The Task Force strongly recommends that physicians carry out CRC screening tests for both men and women who are 50 years of age or older. The Task Force found fair or good evidence that: 1 several screening methods are effective in reducing mortality from CRC, 2 the benefits of screening outweigh its risks, although the quality of the tests, the magnitude of the benefits, and the potential harms vary according to the method, and 3 periodic fecal occult blood testing (FOBT reduces mortality from CRC. In addition, there is fair evidence that sigmoidoscopy, either alone or in combination with FOBT, reduces CRC mortality. There is no direct evidence that screening colonoscopy is effective in reducing CRC mortality, nor is it clear if the greater accuracy of colonoscopy in comparison to other tests compensates for its additional complications, inconvenience, and costs. Double-contrast barium enema is less sensitive than colonoscopy, and there is no direct evidence that it is effective in lowering mortality rates. There are insufficient data to determine which screening strategy is best in terms of the balance of benefits, potential harms, and cost-effectiveness. Regardless of the strategy chosen, CRC screening is likely to be cost-effective (less than US$ 30 000 per year of life gained.

  12. Effectiveness of a primary care practice intervention for increasing colorectal cancer screening in Appalachian Kentucky.

    Science.gov (United States)

    Dignan, Mark; Shelton, Brent; Slone, Stacey A; Tolle, Cheri; Mohammad, Sohail; Schoenberg, Nancy; Pearce, Kevin; Van Meter, Emily; Ely, Gretchen

    2014-01-01

    This report describes findings from a randomized controlled trial of an intervention to increase colorectal cancer (CRC) screening in primary care practices in Appalachian Kentucky. Sixty-six primary care practices were randomized to early or delayed intervention groups. The intervention was provided at practices using academic detailing, a method of education where providers receive information on a specific topic through personal contact. Data were collected in cross-sectional surveys of medical records at baseline and six months post-intervention. A total of 3844 medical records were reviewed at baseline and 3751 at the six-month follow-up. At baselines, colonoscopy was recommended more frequently (43.4%) than any other screening modality, followed by fecal occult blood testing (18.0%), flexible sigmoidoscopy (0.4%), and double-contrast barium enema (0.3%). Rates of documented screening results were higher for all practices at the six-month follow-up for colonoscopy (31.8% vs 29.6%) and fecal occult blood testing (12.2% vs 11.2%). For early intervention practices that recommended screening, colonoscopy rates increased by 15.7% at six months compared to an increase of 2.4% in the delayed intervention practices (p=.01). Using academic detailing to reach rural primary care providers with a CRC screening intervention was associated with an increase in colonoscopy. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Factors associated with adenoma detection rate and diagnosis of polyps and colorectal cancer during colonoscopy in France: results of a prospective, nationwide survey.

    Directory of Open Access Journals (Sweden)

    Maximilien Barret

    Full Text Available INTRODUCTION: Colonoscopy can prevent deaths due to colorectal cancer (CRC through early diagnosis or resection of colonic adenomas. We conducted a prospective, nationwide study on colonoscopy practice in France. METHODS: An online questionnaire was administered to 2,600 French gastroenterologists. Data from all consecutive colonoscopies performed during one week were collected. A statistical extrapolation of the results to a whole year was performed, and factors potentially associated with the adenoma detection rate (ADR or the diagnosis of polyps or cancer were assessed. RESULTS: A total of 342 gastroenterologists, representative of the overall population of French gastroenterologists, provided data on 3,266 colonoscopies, corresponding to 1,200,529 (95% CI: 1,125,936-1,275,122 procedures for the year 2011. The indication for colonoscopy was CRC screening and digestive symptoms in 49.6% and 38.9% of cases, respectively. Polypectomy was performed in 35.5% of cases. The ADR and prevalence of CRC were 17.7% and 2.9%, respectively. The main factors associated with a high ADR were male gender (p=0.0001, age over 50 (p=0.0001, personal or family history of CRC or colorectal polyps (p<0.0001 and p<0.0001, respectively, and positive fecal occult blood test (p=0.0005. The prevalence of CRC was three times higher in patients with their first colonoscopy (4.2% vs. 1.4%; p<0.0001. CONCLUSIONS: For the first time in France, we report nationwide prospective data on colonoscopy practice, including histological results. We found an average ADR of 17.7%, and observed reduced CRC incidence in patients with previous colonoscopy.

  14. Adenoma detection rate varies greatly during colonoscopy training

    NARCIS (Netherlands)

    van Doorn, Sascha C.; Klanderman, Robert B.; Hazewinkel, Yark; Fockens, Paul; Dekker, Evelien

    2015-01-01

    The adenoma detection rate (ADR) is considered the most important quality indicator for colonoscopy and varies widely among colonoscopists. It is unknown whether the ADR of gastroenterology consultants can already be predicted during their colonoscopy training. To evaluate the ADR of fellows in

  15. Location of colorectal cancer: colonoscopy versus surgery. Yield of colonoscopy in predicting actual location.

    Science.gov (United States)

    Blum-Guzman, Juan Pablo; Wanderley de Melo, Silvio

    2017-07-01

     Recent studies suggest that differences in biological characteristics and risk factors across cancer site within the colon and rectum may translate to differences in survival. It can be challenging at times to determine the precise anatomical location of a lesion with a luminal view during colonoscopy. The aim of this study is to determine if there is a significant difference between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative and pathology reports after colon surgery.  A single-center retrospective analysis of colonoscopies of patient with reported colonic masses from January 2005 to April 2014 (n = 380) was carried. Assessed data included demography, operative and pathology reports. Findings were compared: between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative reports or pathology samples.  We identified 380 colonic masses, 158 were confirmed adenocarcinomas. Of these 123 underwent surgical resection, 27 had to be excluded since no specific location was reported on their operative or pathology report. An absolute difference between endoscopic and surgical location was found in 32 cases (33 %). Of these, 22 (23 %) differed by 1 colonic segment, 8 (8 %) differed by 2 colonic segments and 2 (2 %) differed by 3 colonic segments.  There is a significant difference between the location of colorectal cancers reported by gastroenterologists during endoscopy and the actual anatomical location noted on operative or pathology reports after colon surgery. Endoscopic tattooing should be used when faced with any luminal lesions of interest.

  16. Organized colorectal cancer screening in Serbia - the first round within 2013-2014

    Directory of Open Access Journals (Sweden)

    Banković-Lazarević Dušica

    2016-01-01

    Full Text Available Background/Aim. The National Organized Colorectal Cancer Screening Program was conducted in the Republic of Serbia during 2013-2014 covering the population of both genders, aged 50 to 74 years, in 28 municipalities out of 180, with the target population of 651,445 people. This organized colorectal cancer screening aims to reduce mortality from colorectal cancer in the target population. The aim of this study was to show the results of organized screening for colorectal cancer during the first biannual round in Serbia. Methods. General practitioners from the primary health centers, invited target population by letters and by phone to perform immunochemical fecal occult blood test. Persons with a positive test results were referred to the colonoscopy. The database of health insurance and other citizens of the target population was used for invitation for screening in primary health centers. Descriptive statistical analysis of the results in organized colorectal cancer screening in the first round was performed for the key screening indicators. Results. In the first round, a total of 99,592 persons were invited. The participation rate was 62.5%. Colonoscopy was performed in 1,554 persons. Adenomas were found in 586 persons (0.9% of all the tested, e.g. 37.7 % of all colonoscopied. In 129 persons colorectal cancer was diagnosed (0.2% of all the tested, e.g. 8.3% of all the colonoscopied. In the left half of the colon (rectum, sigmoid and descending colon there were 70.4% diagnosed polyps and 77.3% carcinomas, while 29.6% of polyps and 22.7% carcinomas were found in the proximal parts of the colon. Conclusion. In the first round of the organized colorectal cancer screening in Serbia the participation rate of the targeted population was high and gave encouraging result. It was expected that in the forthcoming rounds even higher coverage of the target population would be accomplished. A positive predictive value of the completed colonoscopies showed

  17. Clinical and Molecular Characteristics of Post-Colonoscopy Colorectal Cancer: A Population-based Study.

    Science.gov (United States)

    Stoffel, Elena M; Erichsen, Rune; Frøslev, Trine; Pedersen, Lars; Vyberg, Mogens; Koeppe, Erika; Crockett, Seth D; Hamilton, Stanley R; Sørensen, Henrik T; Baron, John A

    2016-11-01

    Colonoscopy provides incomplete protection from colorectal cancer (CRC), but determinants of post-colonoscopy CRC are not well understood. We compared clinical features and molecular characteristics of CRCs diagnosed at different time intervals after a previous colonoscopy. We performed a population-based, cross-sectional study of incident CRC cases in Denmark (2007-2011), categorized as post-colonoscopy or detected during diagnostic colonoscopy (in patients with no prior colonoscopy). We compared prevalence of proximal location and DNA mismatch repair deficiency (dMMR) in CRC tumors, relative to time since previous colonoscopy, using logistic regression and cubic splines to assess temporal variation. Of 10,365 incident CRCs, 725 occurred after colonoscopy examinations (7.0%). These were more often located in the proximal colon (odds ratio [OR], 2.34; 95% confidence interval [CI], 1.90-2.89) and were more likely to have dMMR (OR, 1.26; 95% CI, 1.00-1.59), but were less likely to be metastatic at presentation (OR, 0.65; 95% CI, 0.48-0.89) compared with CRCs diagnosed in patients with no prior colonoscopy. The highest proportions of proximal and/or dMMR tumors were observed in CRCs diagnosed 3-6 years after colonoscopy, but these features were still more frequent among cancers diagnosed up to 10 years after colonoscopy. The relative excess of dMMR tumors was most pronounced in distal cancers. In an analysis of 85 cases detected after colonoscopy, we found BRAF mutations in 23% of tumors and that 7% of cases had features of Lynch syndrome. Colonoscopy exams were incomplete in a higher proportion of cases diagnosed within <1 year (in 38%) than in those diagnosed within 1-10 years after colonoscopy (16%). In a study of incident CRC cases in Denmark, we observed that tumors found in patients who have undergone colonoscopy are more often proximal and have dMMR compared to CRCs detected in patients without previous colonoscopies. The excess of right-sided tumors and

  18. An international review of the main cost-effectiveness drivers of virtual colonography versus conventional colonoscopy for colorectal cancer screening: is the tide changing due to adherence?

    Science.gov (United States)

    Kriza, Christine; Emmert, Martin; Wahlster, Philip; Niederländer, Charlotte; Kolominsky-Rabas, Peter

    2013-11-01

    The majority of recent cost-effectiveness reviews concluded that computerised tomographic colonography (CTC) is not a cost-effective colorectal cancer (CRC) screening strategy yet. The objective of this review is to examine cost-effectiveness of CTC versus optical colonoscopy (COL) for CRC screening and identify the main drivers influencing cost-effectiveness due to the emergence of new research. A systematic review was conducted for cost-effectiveness studies comparing CTC and COL as a screening tool and providing outcomes in life-years saved, published between January 2006 and November 2012. Nine studies were included in the review. There was considerable heterogeneity in modelling complexity and methodology. Different model assumptions and inputs had large effects on resulting cost-effectiveness of CTC and COL. CTC was found to be dominant or cost-effective in three studies, assuming the most favourable scenario. COL was found to be not cost effective in one study. CTC has the potential to be a cost-effective CRC screening strategy when compared to COL. The most important assumptions that influenced the cost-effectiveness of CTC and COL were related to CTC threshold-based reporting of polyps, CTC cost, CTC sensitivity for large polyps, natural history of adenoma transition to cancer, AAA parameters and importantly, adherence. There is a strong need for a differential consideration of patient adherence and compliance to CTC and COL. Recent research shows that laxative-free CTC screening has the potential to become a good alternative screening method for CRC as it can improve patient uptake of screening. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. An international review of the main cost-effectiveness drivers of virtual colonography versus conventional colonoscopy for colorectal cancer screening: Is the tide changing due to adherence?

    Energy Technology Data Exchange (ETDEWEB)

    Kriza, Christine, E-mail: Christine.kriza@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany); Emmert, Martin, E-mail: Martin.Emmert@fau.de [School of Business and Economics, Institute of Management, University of Erlangen-Nuremberg, Lange Gasse 20, 90403 Nuremberg (Germany); Wahlster, Philip, E-mail: Philip.wahlster@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany); Niederländer, Charlotte, E-mail: Charlotte.niederlaender@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany); Kolominsky-Rabas, Peter, E-mail: Peter.kolominsky@uk-erlangen.de [Interdisciplinary Centre for Health Technology Assessment and Public Health, University of Erlangen-Nuremberg, National BMBF-Cluster of Excellence, “Medical Technologies - Medical Valley EMN”, Schwabachanlage 6, 91054 Erlangen (Germany)

    2013-11-01

    Objectives: The majority of recent cost-effectiveness reviews concluded that computerised tomographic colonography (CTC) is not a cost-effective colorectal cancer (CRC) screening strategy yet. The objective of this review is to examine cost-effectiveness of CTC versus optical colonoscopy (COL) for CRC screening and identify the main drivers influencing cost-effectiveness due to the emergence of new research. Methods: A systematic review was conducted for cost-effectiveness studies comparing CTC and COL as a screening tool and providing outcomes in life-years saved, published between January 2006 and November 2012. Results: Nine studies were included in the review. There was considerable heterogeneity in modelling complexity and methodology. Different model assumptions and inputs had large effects on resulting cost-effectiveness of CTC and COL. CTC was found to be dominant or cost-effective in three studies, assuming the most favourable scenario. COL was found to be not cost effective in one study. Conclusions: CTC has the potential to be a cost-effective CRC screening strategy when compared to COL. The most important assumptions that influenced the cost-effectiveness of CTC and COL were related to CTC threshold-based reporting of polyps, CTC cost, CTC sensitivity for large polyps, natural history of adenoma transition to cancer, AAA parameters and importantly, adherence. There is a strong need for a differential consideration of patient adherence and compliance to CTC and COL. Recent research shows that laxative-free CTC screening has the potential to become a good alternative screening method for CRC as it can improve patient uptake of screening.

  20. An international review of the main cost-effectiveness drivers of virtual colonography versus conventional colonoscopy for colorectal cancer screening: Is the tide changing due to adherence?

    International Nuclear Information System (INIS)

    Kriza, Christine; Emmert, Martin; Wahlster, Philip; Niederländer, Charlotte; Kolominsky-Rabas, Peter

    2013-01-01

    Objectives: The majority of recent cost-effectiveness reviews concluded that computerised tomographic colonography (CTC) is not a cost-effective colorectal cancer (CRC) screening strategy yet. The objective of this review is to examine cost-effectiveness of CTC versus optical colonoscopy (COL) for CRC screening and identify the main drivers influencing cost-effectiveness due to the emergence of new research. Methods: A systematic review was conducted for cost-effectiveness studies comparing CTC and COL as a screening tool and providing outcomes in life-years saved, published between January 2006 and November 2012. Results: Nine studies were included in the review. There was considerable heterogeneity in modelling complexity and methodology. Different model assumptions and inputs had large effects on resulting cost-effectiveness of CTC and COL. CTC was found to be dominant or cost-effective in three studies, assuming the most favourable scenario. COL was found to be not cost effective in one study. Conclusions: CTC has the potential to be a cost-effective CRC screening strategy when compared to COL. The most important assumptions that influenced the cost-effectiveness of CTC and COL were related to CTC threshold-based reporting of polyps, CTC cost, CTC sensitivity for large polyps, natural history of adenoma transition to cancer, AAA parameters and importantly, adherence. There is a strong need for a differential consideration of patient adherence and compliance to CTC and COL. Recent research shows that laxative-free CTC screening has the potential to become a good alternative screening method for CRC as it can improve patient uptake of screening

  1. Eliciting population preferences for mass colorectal cancer screening organization.

    Science.gov (United States)

    Nayaradou, Maximilien; Berchi, Célia; Dejardin, Olivier; Launoy, Guy

    2010-01-01

    The implementation of mass colorectal cancer (CRC) screening is a public health priority. Population participation is fundamental for the success of CRC screening as for any cancer screening program. The preferences of the population may influence their likelihood of participation. The authors sought to elicit population preferences for CRC screening test characteristics to improve the design of CRC screening campaigns. A discrete choice experiment was used. Questionnaires were compiled with a set of pairs of hypothetical CRC screening scenarios. The survey was conducted by mail from June 2006 to October 2006 on a representative sample of 2000 inhabitants, aged 50 to 74 years from the northwest of France, who were randomly selected from electoral lists. Questionnaires were sent to 2000 individuals, each of whom made 3 or 4 discrete choices between hypothetical tests that differed in 7 attributes: how screening is offered, process, sensitivity, rate of unnecessary colonoscopy, expected mortality reduction, method of screening test result transmission, and cost. Complete responses were received from 656 individuals (32.8%). The attributes that influenced population preferences included expected mortality reduction, sensitivity, cost, and process. Participants from high social classes were particularly influenced by sensitivity. The results demonstrate that the discrete choice experiment provides information on patient preferences for CRC screening: improving screening program effectiveness, for instance, by improving test sensitivity (the most valued attribute) would increase satisfaction among the general population with regard to CRC screening programs. Additional studies are required to study how patient preferences actually affect adherence to regular screening programs.

  2. Effect Supermint oil (Peppermint oil on children's pain during Colonoscopy

    Directory of Open Access Journals (Sweden)

    M Najafi

    2014-04-01

    Full Text Available Introduction: Pain during colonoscopy, especially in children, including the challenges faced by the medical team. The aim of study was investigation the analgesic effect Supermint oil (peppermint oil on pain in children during colonoscopy. Methods and Materials: In this clinical trial study, 101 children (7-14 years old candidate colonoscopy were randomly divided into two groups, respectively. About half an hour before the colonoscopy case group (n=51 was administrated oral drops Supermint oil (peppermint oil. Patients were filled a pediatric pain questionnaire. In control group (n=50 filled a questionnaire without any administration. Data were analyzed using SPSS version 11.5 and (T-test and Paired sample t-test, Corraletion,Man withney. Results: Mean value of pain, duration of colonoscopy in control group was 5/60+1/85 and in case group was 4/20+1/70 and this diference was significant (P

  3. The Quebec Association of Gastroenterology Position Paper on Colorectal Cancer Screening - 2003

    Directory of Open Access Journals (Sweden)

    AN Barkun

    2004-01-01

    Full Text Available Colorectal cancer is a leading cause of death and the third most common cancer in Canada. Evidence suggests that screening can reduce mortality rates and the cost effectiveness of a program compares favourably with initiatives for breast and cervical cancer. The objectives of the Association des gastro-entérologues du Québec Task Force were to determine the need for a policy on screening for colorectal cancer in Quebec, to evaluate the testing methods available and to propose one or more of these alternatives as part of a formal screening program, if indicated. Fecal occult blood testing (FOBT, endoscopy (including sigmoidoscopy and colonoscopy, barium enema and virtual colonoscopy were considered. Although most clinical efficacy data are available for FOBT and sigmoidoscopy, there are limitations to programs based on these strategies. FOBT has a high false positive rate and a low detection yield, and even a combination of these strategies will miss 24% of cancers. Colonoscopy is the best strategy to both detect and remove polyps and to diagnose colorectal cancer, with double contrast barium enema also being a sensitive detection method. The Task Force recommended the establishment, in Quebec, of a screening program with five- to 10-yearly double contrast barium enema or 10-yearly colonoscopy for individuals aged 50 years or older at low risk. The program should include outcome monitoring, public and professional education to increase awareness and promote compliance, and central coordination with other provincial programs. The program should be evaluated; specific billing codes for screening for colorectal cancer would help facilitate this. Formal feasibility, effectiveness and cost-effectiveness studies in Quebec are now warranted.

  4. Acculturation and Cancer Screening among Asian Americans: Role of Health Insurance and Having a Regular Physician

    OpenAIRE

    Lee, Sunmin; Chen, Lu; Jung, Mary Y.; Baezconde-Garbanati, Lourdes; Juon, Hee-Soon

    2014-01-01

    Cancer is the leading cause of death among Asian Americans, but screening rates are significantly lower in Asians than in non-Hispanic Whites. This study examined associations between acculturation and three types of cancer screening (colorectal, cervical, and breast), focusing on the role of health insurance and having a regular physician. A cross-sectional study of 851 Chinese, Korean, and Vietnamese Americans was conducted in Maryland. Acculturation was measured using an abridged version o...

  5. Glaucoma screening during regular optician visits : can the population at risk of developing glaucoma be reached?

    NARCIS (Netherlands)

    Stoutenbeek, R.; Jansonius, N. M.

    2006-01-01

    Aim: To determine the percentage of the population at risk of developing glaucoma, which can potentially be reached by conducting glaucoma screening during regular optician visits. Methods: 1200 inhabitants aged > 40 years were randomly selected from Dutch community population databases. A

  6. RHYTHM DISTURBANCES DURING COLONOSCOPY

    Directory of Open Access Journals (Sweden)

    D. Jordanov

    2012-08-01

    Full Text Available Purpose: The purpose of this study is to assess the risk of inducing rhythm disturbances of the heart during colonoscopy.Patients and methods used: 80 patients had undergone colonoscopyper formed by two experienced specialists of endoscopy for the period from March to December 2011. The endoscopies were performed without premedication and sedation. Holter was placed on each patient one hour before the endoscopic examination, and the record continued one hour after the manipulation. The blood pressure was measured before, during and after the procedure.Results: During colonoscopy 25 patients (31,25% manifested rhythm disorders. In 15 patients (18,75% sinus tachycardia occurred. In 7 patients (8,75% suptraventricular extra systoles were observed and in 3 patients (3,75% - ventricular extra systoles. No ST-T changes were found. Highest values of the blood pressure were measured before and during the endoscopy, but the values did not exceed 160/105 mmHg. In 10 patients (12,5% a hypotensive reaction was observed, bur the values were not lower than 80/ 50. In 2 patients there was a short bradycardia with a heart frequency 50-55 /min.Conclusions: Our results showed that the rhythm disorders during lower colonoscopy occur in approximately 1/3 of the examined patients, there is an increase or decrease of the blood pressure in some patients, but that doesn’t require physician’s aid and the examination can be carried out safely without monitoring.

  7. Costs of Finding an Advanced Adenoma in Colorectal Screening

    Directory of Open Access Journals (Sweden)

    Jerome B Simon

    2004-01-01

    Full Text Available The authors used computerized decision analysis to estimate the costs of finding and removing an advanced colonic adenoma in patients referred because of a positive fecal occult blood test. An advanced adenoma was defined as a villous adenoma, a tubular adenoma 10 mm or more in size, or a lesion that harboured highgrade dysplasia or cancer. Four strategies were compared: flexible sigmoidoscopy, flexible sigmoidoscopy plus air contrast barium enema, virtual colonoscopy (CT colography and colonoscopy. Colonoscopy with polypectomy was undertaken if any of the methods detected a polyp. Probabilities and test characteristics were determined from the literature, and costs were estimated from the provincial fee schedule (Ontario and local hospital sources. With an assumed 17% probability of an advanced adenoma being present, sigmoidoscopy was the most cost effective strategy at $1930 to find and clear an advanced lesion, but the procredure missed between one-third and almost one-half of the lesions, depending on the depth of insertion. At $2290, colonoscopy was slightly more expensive than sigmoidoscopy and more cost effective than either sigmoidoscopy plus barium enema ($2840 or virtual colonoscopy ($3681, neither of which detected as many advanced adenomas. The authors concluded that colonoscopy is the preferred investigative strategy and that improved access to colonoscopy is an important goal for occult blood screening programs.

  8. Impact of bowel preparation type on the quality of colonoscopy: a multicenter community-based study

    Directory of Open Access Journals (Sweden)

    Daniel Martin

    2016-04-01

    Full Text Available Background: High-quality bowel preparation is crucial for achieving the goals of colonoscopy. However, choosing a bowel preparation in clinical practice can be challenging because of the many formulations. This study aims to assess the impact the type of bowel preparation on the quality of colonoscopy in a community hospital setting. Methods: A retrospective, observational study was conducted utilizing a colonoscopy screening/surveillance database in central Illinois during the period of January 1, 2010, to March 31, 2014. Patients without bowel preparation assessment were excluded from this study. Controlling for the confounders, generalized linear models were used to estimate the adjusted impact [odds ratio (OR] of bowel preparation type on the quality of preparation (excellent, good, fair, and poor, and on the detection of advanced adenoma. The association between the time of withdrawal after insertion and the quality of preparation was also examined using a linear model. Results: A total of 28,368 colonoscopies; half the patients were male, and the average age was 61±9 years. Polyethylene glycol (PEG was used in the majority (70.2% of bowel preparations, followed by sodium sulfate (21.4%, sodium phosphate (2.5%, magnesium sulfate (0.4%, and others. Compared with PEG, magnesium sulfate had a poorer quality of bowel preparations (OR=0.6, 95% CI 0.4–0.9; p<0.05, whereas the quality of bowel preparation was significantly improved by using sodium sulfate (OR=5.7, 95% CI 5.4–6.1; p<0.001 and sodium phosphate (OR=2.1, 95% CI 1.8–2.5; p<0.001. For those who had adequate bowel preparation, the better quality of preparation significantly increased the detection rate of advanced adenoma (5.0, 3.6, and 2.9% for excellent, good, and fair, respectively. Conclusion: When possible, sodium sulfate–based preparations should be recommended in the community setting for colonoscopy because of their high quality of bowel preparation.

  9. Splenic Trauma during Colonoscopy: The Role of Intra-Abdominal Adhesions

    OpenAIRE

    Chime, Chukwunonso; Ishak, Charbel; Kumar, Kishore; Kella, Venkata; Chilimuri, Sridhar

    2018-01-01

    Splenic rupture following colonoscopy is rare, first reported in 1974, with incidence of 1–21/100,000. It is critical to anticipate splenic trauma during colonoscopy as one of the causes of abdominal pain after colonoscopy especially when located in the left upper quadrant or left shoulder. Postoperative adhesions is a predisposing factor for splenic injury, and management is either operative or nonoperative, based on hemodynamic stability and/or extravasation which can be seen on contrast-en...

  10. Detection rate of serrated polyps and serrated polyposis syndrome in colorectal cancer screening cohorts: a European overview.

    Science.gov (United States)

    IJspeert, J E G; Bevan, R; Senore, C; Kaminski, M F; Kuipers, E J; Mroz, A; Bessa, X; Cassoni, P; Hassan, C; Repici, A; Balaguer, F; Rees, C J; Dekker, E

    2017-07-01

    The role of serrated polyps (SPs) as colorectal cancer precursor is increasingly recognised. However, the true prevalence SPs is largely unknown. We aimed to evaluate the detection rate of SPs subtypes as well as serrated polyposis syndrome (SPS) among European screening cohorts. Prospectively collected screening cohorts of ≥1000 individuals were eligible for inclusion. Colonoscopies performed before 2009 and/or in individuals aged below 50 were excluded. Rate of SPs was assessed, categorised for histology, location and size. Age-sex-standardised number needed to screen (NNS) to detect SPs were calculated. Rate of SPS was assessed in cohorts with known colonoscopy follow-up data. Clinically relevant SPs (regarded as a separate entity) were defined as SPs ≥10 mm and/or SPs >5 mm in the proximal colon. Three faecal occult blood test (FOBT) screening cohorts and two primary colonoscopy screening cohorts (range 1.426-205.949 individuals) were included. Rate of SPs ranged between 15.1% and 27.2% (median 19.5%), of sessile serrated polyps between 2.2% and 4.8% (median 3.3%) and of clinically relevant SPs between 2.1% and 7.8% (median 4.6%). Rate of SPs was similar in FOBT-based cohorts as in colonoscopy screening cohorts. No apparent association between the rate of SP and gender or age was shown. Rate of SPS ranged from 0% to 0.5%, which increased to 0.4% to 0.8% after follow-up colonoscopy. The detection rate of SPs is variable among screening cohorts, and standards for reporting, detection and histopathological assessment should be established. The median rate, as found in this study, may contribute to define uniform minimum standards for males and females between 50 and 75 years of age. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Expressions of machismo in colorectal cancer screening among New Mexico Hispanic subpopulations.

    Science.gov (United States)

    Getrich, Christina M; Sussman, Andrew L; Helitzer, Deborah L; Hoffman, Richard M; Warner, Teddy D; Sánchez, Victoria; Solares, Angélica; Rhyne, Robert L

    2012-04-01

    Although national colorectal cancer (CRC) incidence rates have steadily decreased, the rate for New Mexico Hispanics has been increasing, and screening rates are low. We conducted an exploratory qualitative study to determine barriers to CRC screening for New Mexico Hispanics. We found that machismo served as a dynamic influence on men's health-seeking behaviors; however, it was conceptualized differently by two distinct Hispanic subpopulations, and therefore appeared to play a different role in shaping their screening attitudes and behaviors. Machismo emerged as more of an influence for Mexican men, who expressed concern over colonoscopies being potentially transformative and/or stigmatizing, but was not as salient for Hispanos, who viewed the colonoscopy as "strictly medical," and were more concerned with discomfort and pain. Findings from the study highlight the importance of identifying varying characteristics among subpopulations to better understand screening barriers and provide optimal CRC screening counseling in primary care settings.

  12. Clinicians' perceptions of the benefits and harms of prostate and colorectal cancer screening.

    Science.gov (United States)

    Elstad, Emily A; Sutkowi-Hemstreet, Anne; Sheridan, Stacey L; Vu, Maihan; Harris, Russell; Reyna, Valerie F; Rini, Christine; Earp, Jo Anne; Brewer, Noel T

    2015-05-01

    Clinicians' perceptions of screening benefits and harms influence their recommendations, which in turn shape patients' screening decisions. We sought to understand clinicians' perceptions of the benefits and harms of cancer screening by comparing 2 screening tests that differ in their balance of potential benefits to harms: colonoscopy, which results in net benefit for many adults, and prostate-specific antigen (PSA) testing, which may do more harm than good. In this cross-sectional study, 126 clinicians at 24 family/internal medicine practices completed surveys in which they listed and rated the magnitude of colonoscopy and PSA testing benefits and harms for a hypothetical 70-year-old male patient and then estimated the likelihood that these tests would cause harm and lengthen the life of 100 similar men in the next 10 years. We tested the hypothesis that the availability heuristic would explain the association of screening test to perceived likelihood of benefit/harm and a competing hypothesis that clinicians' gist of screening tests as good or bad would mediate this association. Clinicians perceived PSA testing to have a greater likelihood of harm and a lower likelihood of lengthening life relative to colonoscopy. Consistent with our gist hypothesis, these associations were mediated by clinicians' gist of screening (balance of perceived benefits to perceived harms). Generalizability beyond academic clinicians remains to be established. Targeting clinicians' gist of screening, for example through graphical displays that allow clinicians to make gist-based relative magnitude comparisons, may influence their risk perception and possibly reduce overrecommendation of screening. © The Author(s) 2015.

  13. An updated Asia Pacific Consensus Recommendations on colorectal cancer screening.

    Science.gov (United States)

    Sung, J J Y; Ng, S C; Chan, F K L; Chiu, H M; Kim, H S; Matsuda, T; Ng, S S M; Lau, J Y W; Zheng, S; Adler, S; Reddy, N; Yeoh, K G; Tsoi, K K F; Ching, J Y L; Kuipers, E J; Rabeneck, L; Young, G P; Steele, R J; Lieberman, D; Goh, K L

    2015-01-01

    Since the publication of the first Asia Pacific Consensus on Colorectal Cancer (CRC) in 2008, there are substantial advancements in the science and experience of implementing CRC screening. The Asia Pacific Working Group aimed to provide an updated set of consensus recommendations. Members from 14 Asian regions gathered to seek consensus using other national and international guidelines, and recent relevant literature published from 2008 to 2013. A modified Delphi process was adopted to develop the statements. Age range for CRC screening is defined as 50-75 years. Advancing age, male, family history of CRC, smoking and obesity are confirmed risk factors for CRC and advanced neoplasia. A risk-stratified scoring system is recommended for selecting high-risk patients for colonoscopy. Quantitative faecal immunochemical test (FIT) instead of guaiac-based faecal occult blood test (gFOBT) is preferred for average-risk subjects. Ancillary methods in colonoscopy, with the exception of chromoendoscopy, have not proven to be superior to high-definition white light endoscopy in identifying adenoma. Quality of colonoscopy should be upheld and quality assurance programme should be in place to audit every aspects of CRC screening. Serrated adenoma is recognised as a risk for interval cancer. There is no consensus on the recruitment of trained endoscopy nurses for CRC screening. Based on recent data on CRC screening, an updated list of recommendations on CRC screening is prepared. These consensus statements will further enhance the implementation of CRC screening in the Asia Pacific region. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Clinical outcomes of surveillance colonoscopy for patients with sessile serrated adenoma

    Directory of Open Access Journals (Sweden)

    Sung Jae Park

    2018-01-01

    Full Text Available Background/Aims: Sessile serrated adenomas (SSAs are known to be precursors of colorectal cancer (CRC. The proper interval of follow-up colonoscopy for SSAs is still being debated. We sought to determine the proper interval of colonoscopy surveillance in patients diagnosed with SSAs in South Korea. Methods: We retrospectively reviewed the medical records of patients diagnosed with SSAs who received 1 or more follow-up colonoscopies. The information reviewed included patient baseline characteristics, SSA characteristics, and colonoscopy information. Results: From January 2007 to December 2011, 152 SSAs and 8 synchronous adenocarcinomas were identified in 138 patients. The mean age of the patients was 62.2 years and 60.1% patients were men. SSAs were located in the right colon (i.e., from the cecum to the hepatic flexure in 68.4% patients. At the first follow-up, 27 SSAs were identified in 138 patients (right colon, 66.7%. At the second follow-up, 6 SSAs were identified in 65 patients (right colon, 66.7%. At the 3rd and 4th follow-up, 21 and 11 patients underwent colonoscopy, respectively, and no SSAs were detected. The total mean follow-up duration was 33.9 months. The mean size of SSAs was 8.1±5.0 mm. SSAs were most commonly found in the right colon (126/185, 68.1%. During annual follow-up colonoscopy surveillance, no cancer was detected. Conclusions: Annual colonoscopy surveillance is not necessary for identifying new CRCs in all patients diagnosed with SSAs. In addition, the right colon should be examined more carefully because SSAs occur more frequently in the right colon during initial and follow-up colonoscopies.

  15. Colonoscopy: Evaluating indications and diagnostic yield

    International Nuclear Information System (INIS)

    Al-Shamali, Mohammed A.; Hasan, F.; Siddiqe, I.; Al-Nakeeb, B.; Kalaoui, M.; Khajah, A.

    2001-01-01

    Colonoscopic procedure is an accepted modality for the evaluation ofcolonic disease. Open-access versus restricted-access colonoscopy has beenargued over in the recent literature. The aim of this retrospective analysisis to identify the yield of the major indications for the procedure, and thepattern of colon pathology in our community. We retrospectively analyzed ourexperience in 3000 colonoscopies over a five-year period. The patientscomprised 1145 females (38%) and 1855 males (62%) and their ages ranged from9 months to 95 years (mean 39.2). There were 2283 patients (76%) who wereaged less than 55 years. Complete examination to the cecum was possible in2850 cases (95%). Pathological findings were identified in 640 patients(21%). The diagnostic yield of patients referred for lower abdominal pain andsurveillance was low, at 7% and 17%, respectively. The yield was high forthose with lower gastrointestinal bleeding (47%), non-bloody diarrhea (35%),iron deficiency anemia (30%), mass lesions identified by radiology (53%) andpolyps identified by radiology (70%). Inflammatory bowel disease wasdiagnosed in 220 patients, carcinoma in 64 patients and colonic polyps in 139patients. Colonic diseases are not uncommon in our part of the world.Colonoscopy is a rewarding procedure in those patients referred with lowergastrointestinal bleeding, mass lesions, polyps and diarrhea. The procedureis less rewarding in patients with lower abdominal pain and in thoseundergoing surveillance colonoscopy. Patient selection on the basis of thepresenting complaint may help to utilize the limited resource available togastroenterologists. About 63% of the procedures were done for indicationsfound to have a low yield. Inflammatory bowel disease is seen with increasingfrequency in our population. (author)

  16. Indications for colonoscopy

    African Journals Online (AJOL)

    symptoms,I endoscopic examination of the colon in patients with suspected colonic disease is not as univer- sally accepted. It remains current practice for many of these patients to be ... disease.2 In addition colonoscopy can act as both a diag- nostic and a ... tic method in cases of suspected colonic disease.' While this may ...

  17. Improved haptic interface for colonoscopy simulation.

    Science.gov (United States)

    Woo, Hyun Soo; Kim, Woo Seok; Ahn, Woojin; Lee, Doo Yong; Yi, Sun Young

    2007-01-01

    This paper presents an improved haptic interface of the KAIST-Ewha colonoscopy simulator II. The haptic interface enables the distal portion of the colonoscope to be freely bent while guaranteeing enough workspace and reflective forces for colonoscopy simulation. Its force-torque sensor measures profiles of the user. Manipulation of the colonoscope tip is monitored by four deflection sensors, and triggers computation to render accurate graphic images corresponding to the angle knob rotation. Tack switches are attached on the valve-actuation buttons of the colonoscope to simulate air-injection or suction, and the corresponding deformation of the colon.

  18. Splenic injury after colonoscopy

    DEFF Research Database (Denmark)

    Petersen, C.R.; Adamsen, S.; Gocht-Jensen, P.

    2008-01-01

    the colonoscopy, ranging from 4 hours to 7 days, before presenting with signs of splenic injury. In all cases the spleen was torn, and the amount of blood in the peritoneal cavity ranged from 1500 mL to 5000 mL. Two patients died postoperatively. The number of cases reported after 2000 indicates......Splenic injury is a rare and serious complication of colonoscopy. The most likely mechanism is tension on the splenocolic ligament and adhesions. Eight cases were identified among claims for compensation submitted to the Danish Patient Insurance Association during the period 1992-2006, seven...... that this potentially lethal complication might be more common than was previously assumed, and it is possibly under-reported. Preventive measures include good colonoscopic technique to avoid loop formation and the use of excessive force; and it is possible that emerging endoscopic technologies will lead to a reduced...

  19. ORIGINAL ARTICLE: Will An Additional Observer Enhance Adenoma Detection During Colonoscopy?

    Directory of Open Access Journals (Sweden)

    Kevin D Mullen

    2012-07-01

    Full Text Available Background: Due to varied level of experience, the detection rate of adenoma on colonoscopy is different. In presence of both fellows and attending the incidence rates of adenoma are shown to increase in a small study reported by Rogart et al [4]. Based on similar hypothesis, a study was undertaken with much larger sample size to improve the power of the study. Aims and objective: To know if presence of additional observer will enhance adenoma detection during colonoscopy. Material and Methods: 2236 consecutive colonoscopies performed at Metro Health Medical Centre, Cleveland, Ohio were included in the study from July 2005 to August 2006. Cases with history of colorectal, surgical resection of colon, inflammatory bowel diseases and hereditary polyposis syndrome were excluded. Inpatient colonoscopies were also excluded. With all usual precautions for colonoscopy and after giving polyethylene glycol electrolyte (PEGEL colonoscopies were performed by one of the nine experienced staff attending using an Olympus colonoscope and Evis Exera processors. All colonoscopies performed by fellows were supervised by an attending throughout the procedure. Advanced adenomas were defined as adenomas greater than 1 cm size. Statistical analysis was done using Tall hassee, FL software; Fisher’s exact test, unpaired t test and multiple logistic regression analysis were performed. p-value of <0.05 is considered as statistically significant. Results: Of the total 2236 colonoscopies included in the study, 1527 were performed by fellows under supervision of attending and 709 by the attending. There was no significant difference in patient demographics, caecal intubation or poor preparation colonoscopies. The mean age of the group was 55 years in both of the groups. There was no statistically significant different in the polyp detection rate (35% Vs 36.8% as well as overall adenoma detection rate (28.4% Vs 27.7% between these two groups of performers. However

  20. Adherence to colonoscopy recommendations for first-degree relatives of young patients diagnosed with colorectal cancer

    Directory of Open Access Journals (Sweden)

    Guilherme H. Garcia

    2015-10-01

    Full Text Available OBJECTIVES:Colorectal cancer is the third leading cause of cancer death in the United States. The American College of Gastroenterology recommends screening for first-degree relatives of patients diagnosed with colorectal cancer before the age of 50. A colonoscopy is one of the most commonly recommended exams due to its specificity and the possibility to resect pre-malignant lesions. Nevertheless, the rate of physician adherence to this recommendation is unknown.METHODS:This transversal study was performed at a major cancer center in Brazil with 62 patients, aged 18 to 50, who completed a questionnaire on information received from their physicians regarding screening their first-degree relatives. We used the answers from patients who provided explicit consent.RESULTS:Two hundred and three patients were eligible to participate and 93 (45.8% agreed to complete the questionnaire. Twenty-three questionnaires (24.73% were returned and 39 were completed by telephone. Of the patients who answered the questionnaire, 39 (62.9% had received a colonoscopy recommendation for their first-degree relatives and 23 (37.1% were not informed of the recommendation. Among the patients who received the recommendations, 20.51% affirmed that all relatives completed the exam and 51.28% stated that no relatives completed the exam.DISCUSSION:The adherence rate of our physicians to the ACG guideline recommendations was 62.9%. Considering that our study was performed at a leading center for cancer treatment in Latin America, we had expected better adherence. The results show that adherence to the colorectal cancer screening recommendations for high-risk patients must be improved.

  1. Efficacy of prokinetic agents in improving bowel preparation for colonoscopy.

    Science.gov (United States)

    Mishima, Yuko; Amano, Yuji; Okita, Koichi; Takahashi, Yoshiko; Moriyama, Nobuyuki; Ishimura, Norihisa; Furuta, Kenji; Ishihara, Shunji; Adachi, Kyoichi; Kinoshita, Yoshikazu

    2008-01-01

    Colonoscopy plays an important role in the diagnosis and treatment of gastrointestinal illness in both Western countries and Japan. However, preparative bowel cleansing for colonoscopy is frequently troublesome for elderly and/or constipated patients, since they must drink larger volumes of lavage solution for adequate cleansing. We investigated the use of prokinetic agents for improving the efficacy and tolerability of bowel cleansing prior to colonoscopy. 613 patients were divided into two groups according to oral lavage solution used (polyethylene glycol or magnesium citrate), and were further randomized to receive either vehicle (100 ml water) alone, vehicle with 5 mg mosapride citrate, or vehicle with 50 mg itopride hydrochloride 30 min before administration of lavage solution. Experimental parameters included bowel cleansing quality, times to first defecation and completion of bowel cleansing, and incidence of uncomfortable abdominal symptoms during colonoscopy preparation. Administration of mosapride citrate or itopride hydrochloride prior to oral lavage solution did not significantly improve bowel cleansing quality. However, statistically significantly fewer uncomfortable abdominal symptoms were found in patients who received mosapride citrate or itopride hydrochloride versus vehicle alone. Prokinetic agents effectively decreased the incidence of uncomfortable abdominal symptoms experienced during colonoscopy preparation. Copyright 2008 S. Karger AG, Basel.

  2. Colonoscopy can miss diverticula of the left colon identified by barium enema.

    Science.gov (United States)

    Niikura, Ryota; Nagata, Naoyoshi; Shimbo, Takuro; Akiyama, Junichi; Uemura, Naomi

    2013-04-21

    To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema. A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon.

  3. Methods for certification in colonoscopy - a systematic review

    DEFF Research Database (Denmark)

    Preisler, Louise; Svendsen, Morten Bo Søndergaard; Svendsen, Lars Bo

    2018-01-01

    INTRODUCTION: Reliable, valid, and feasible assessment tools are essential to ensure competence in colonoscopy. This study aims to provide an overview of the existing assessment methods and the validity evidence that supports them. METHODS: A systematic search was conducted in October 2016. Pubmed......, EMBASE, and PsycINFO were searched for studies evaluating assessment methods to ensure competency in colonoscopy. Outcome variables were described and evidence of validity was explored using a contemporary framework. RESULTS: Twenty-five observational studies were included in the systematic review. Most...... studies were based on small sample sizes. The studies were categorized after outcome measures into five groups: Clinical process related outcome metrics (n = 2), direct observational colonoscopy assessment (n = 8), simulator based metrics (n = 11), automatic computerized metrics (n = 2), and self...

  4. The role of colonoscopy in managing diverticular disease of the colon.

    Science.gov (United States)

    Tursi, Antonio

    2015-03-01

    Diverticulosis of the colon is frequently found on routine colonoscopy, and the incidence of diverticular disease and its complications appears to be increasing. The role of colonoscopy in managing this disease is still controversial. Colonoscopy plays a key role in managing diverticular bleeding. Several techniques have been effectively used in this field, but band ligation seems to be the best in preventing rebleeding. Colonoscopy is also effective in posing a correct differential diagnosis with other forms of chronic colitis involving colon harbouring diverticula (in particular with Crohn's disease or Segmental Colitis Associated with Diverticulosis). The role of colonoscopy to confirm diagnosis of uncomplicated diverticulitis is still under debate, since the risk of advanced colonic neoplasia in patients admitted for acute uncomplicated diverticulitis is not increased as compared to the average-risk population. On the contrary, colonoscopy is mandatory if patients complain of persistent symptoms or after resolution of an episode of complicated diverticulitis. Finally, a recent endoscopic classification, called Diverticular Inflammation and Complications Assessment (DICA), has been developed and validated. This classification seems to be a promising tool for predicting the outcome of the colon harboring diverticula, but further, prospective studies have to confirm its predictive role on the outcome of the disease.

  5. Usefulness of colonoscopy in ischemic colitis.

    Science.gov (United States)

    Lozano-Maya, M; Ponferrada-Díaz, A; González-Asanza, C; Nogales-Rincón, O; Senent-Sánchez, C; Pérez-de-Ayala, V; Jiménez-Aleixandre, P; Cos-Arregui, E; Menchén-Fernández-Pacheco, P

    2010-07-01

    the ischemic colitis is intestinal the most frequent cause of ischemia. With this work we determine the demographic and clinical characteristics, and the usefulness of the colonoscopy in the patients with ischemic colitis diagnosed in our centre in relation to a change of therapeutic attitude. retrospective study in which were selected 112 patients diagnosed with ischemic colitis by colonoscopy and biopsy, in a period of five years. It was analyzed: age, sex, reason for examination, factors of cardiovascular risk, endoscopic degree of ischemia, change in the therapeutic attitude, treatment and outcome. the average age was of 73.64 + or - 12.10 years with an equal incidence in women (50.9%) and the men (49.1%). The associated factors were the HTA (61.1%), tobacco (37.2%) and antecedents of cardiovascular episode (52.2%). The most frequent reason for colonoscopy was rectorrhagia (53.6%) followed of the abdominal pain (30.4%), being urgent the 65.3%. Colonoscopy allowed a change in the therapeutic attitude in the 50 increasing in the urgent one to the 65.75%. Global mortality was of 27.67%. The serious ischemic colitis (25%) was more frequent in men (64.3%) in urgent indication (85.71%) and attends with high mortality (53.57%). Surgical treatment in the 57.14% was made with a good evolution in the 50%, whereas the patients with mild or moderate ischemic colitis had a better prognosis (favourable evolution in 80.95%) with smaller requirement of the surgical treatment (4.76%), p change of attitude according to the result of the same one. The evidence of a serious colitis supposed an increase of the necessity of surgery and worse prognosis.

  6. The first 2 years of colorectal cancer screening in Ferrara, Italy.

    Science.gov (United States)

    Matarese, Vincenzo G; Feo, Carlo Vittorio; Lanza, Giovanni; Fusetti, Nadia; Carpanelli, Maria Cristina; Cataldo, Serena; Cifalà, Viviana; Ferretti, Stefano; Gafà, Roberta; Marzola, Marina; Montanari, Enrica; Palmonari, Caterina; Simone, Loredana; Trevisani, Lucio; Stockbrugger, Reinhold; Gullini, Sergio

    2011-05-01

    We report on the first screening round in the District of Ferrara, a region of Emilia-Romagna, carried out between March 2005 and March 2007 to illustrate the effort of colorectal cancer (CRC) screening from administration and information to therapy and follow-up. After invitation of 38 344 persons aged 50-69 years (28.5%), 19 480 (50.8%) accepted the immunological faecal occult blood test, with 1 149 (6%) resulting positive. One thousand and one individuals (88.2%) who tested positive for immunological faecal occult blood test accepted examination by either colonoscopy (99.5%) or barium enema (0.5%). Out of 996 screenees having a colonoscopy, 231 had low-risk adenomas (23.2%) and 239 had high-risk adenomas (24%), and were treated endoscopically (96%) or surgically (4%). Ninety-one cancers were diagnosed in 9.1% of colonoscopies (Dukes stadia: A, 58.2%; B, 19.8%; C, 18.7%; D, 3.3%). Fourteen cancers (all in polyps) were treated endoscopically, and the remaining 77 were treated by surgery. One Dukes B patient and 13 of 17 Dukes C patients received adjuvant chemotherapy. Three Dukes D patients had chemotherapy only. During the 2-year study period, 87 screenees had a follow-up colonoscopy: no neoplasia was found in 35 patients initially diagnosed with cancer; low-risk adenomas were found in 31 of 52 patients with initial high-risk adenomas. In conclusion, the first CRC screening round in Ferrara was easy to organize, had a high acceptance, and detected 91 cancers (78% of which were in Dukes stages A and B, compared with only 40% in sporadic CRC in the same background population). Chemotherapy was necessary in 17 cases. This report may motivate other health authorities to initiate CRC screening campaigns.

  7. The bubbling neck: A rare complication from colonoscopy.

    Science.gov (United States)

    Andrejevic, P; Gatt, D

    2012-04-01

    A 70 year old lady presented to the emergency department complaining of "bubbling neck'' and abdominal discomfort. She underwent diagnostic colonoscopy six hours before admission. Clinical examination showed a haemodynamically stable patient and imaging revealed free air in all body compartments. We report a rare case of micro perforation during diagnostic colonoscopy with massive distribution of air in all body compartments, which was successfully treated conservatively. © JSCR.

  8. Identification of factors associated with sedation tolerance in 5000 patients undergoing outpatient colonoscopy: Canadian tertiary center experience.

    Science.gov (United States)

    Shingina, Alexandra; Ou, George; Takach, Oliver; Svarta, Sigrid; Kwok, Ricky; Tong, Jessica; Donaldson, Kieran; Lam, Eric; Enns, Robert

    2016-12-16

    To develop a prediction model aimed at identifying patients that may require higher than usual sedation doses during colonoscopy. A retrospective chart review on 5000 patients who underwent an outpatient colonoscopy at St. Paul's Hospital from 2009 to 2010 was conducted in order to develop a model for identifying patients who will require increased doses of sedatives. Potential predictor variables including age, gender, endoscopy indication, high sedation requirements during previous endoscopies, difficulty of the procedure, bowel preparation quality, interventions, findings as well as current use of benzodiazepines, opioids and alcohol were analyzed. The outcome of study was the use of high dose of sedation agents for the procedure. In particular, the high dose of sedation was defined as fentanyl greater than 50 mcg and midazolam greater than 3 mg. Analysis of 5282 patients (mean age 57 ± 12, 49% female) was performed. Most common indication for the procedure was screening colonoscopy (57%). Almost half of our patients received doses exceeding Fentanyl 50 mcg and Midazolam 3 mg. Logistic regression models identified the following variables associated with high sedation: Younger age (OR = 0.95 95%CI: 0.94-0.95; P value of high sedation requirements. Our prediction model using the following pre-procedural variables including age, gender, indication for the procedure, medication/substance use, previous surgeries, previous high sedation requirements for colonoscopy yielded an area under the curve of 0.76 for Fentanyl ≥ 100 mcg and Midazolam ≥ 3 mg. Pre-procedural planning is the key in conducting successful, efficient colonoscopy. Logistic regression analysis of 5000 patients who underwent out-patient colonoscopy revealed the following factors associated with increased sedation requirement: Younger age, female gender, difficult endoscopy, specific indications as well as cardiopulmonary complications and current use of opioids/benzodiazepines. Age and gender

  9. Outpatient provider concentration and commercial colonoscopy prices.

    Science.gov (United States)

    Pozen, Alexis

    2015-01-01

    The objective was to evaluate the magnitude of various contributors to outpatient commercial colonoscopy prices, including market- and provider-level factors, especially market share. We used adjudicated fee-for-service facility claims from a large commercial insurer for colonoscopies occurring in hospital outpatient department or ambulatory surgery center from October 2005 to December 2012. Claims were matched to provider- and market-level data. Linear fixed effects regressions of negotiated colonoscopy price were run on provider, system, and market characteristics. Markets were defined as counties. There were 178,433 claims from 169 providers (104 systems). The mean system market share was 76% (SD = 0.34) and the mean real (deflated) price was US$1363 (SD = 374), ranging from US$169 to US$2748. For every percentage point increase in a system or individual facility's bed share, relative price increased by 2 to 4 percentage points; this result was stable across a number of specifications. Market population and price were also consistently positively related, though this relation was small in magnitude. No other factor explained price as strongly as market share. Price variation for colonoscopy was driven primarily by market share, of particular concern as the number of mergers increases in wake of the recession and the Affordable Care Act. Whether variation is justified by better quality care requires further research to determine whether quality is subsumed in prices. © The Author(s) 2015.

  10. Procedural Skills Education – Colonoscopy as a Model

    Directory of Open Access Journals (Sweden)

    Maitreyi Raman

    2008-01-01

    Full Text Available Traditionally, surgical and procedural apprenticeship has been an assumed activity of students, without a formal educational context. With increasing barriers to patient and operating room access such as shorter work week hours for residents, and operating room and endoscopy time at a premium, alternate strategies to maximizing procedural skill development are being considered. Recently, the traditional surgical apprenticeship model has been challenged, with greater emphasis on the need for surgical and procedural skills training to be more transparent and for alternatives to patient-based training to be considered. Colonoscopy performance is a complex psychomotor skill requiring practioners to integrate multiple sensory inputs, and involves higher cortical centres for optimal performance. Colonoscopy skills involve mastery in the cognitive, technical and process domains. In the present review, we propose a model for teaching colonoscopy to the novice trainee based on educational theory.

  11. Water exchange method for colonoscopy: learning curve of an experienced colonoscopist in a U.S. community practice setting.

    Science.gov (United States)

    Fischer, Leonard S; Lumsden, Antoinette; Leung, Felix W

    2012-07-01

    Water exchange colonoscopy has been reported to reduce examination discomfort and to provide salvage cleansing in unsedated or minimally sedated patients. The prolonged insertion time and perceived difficulty of insertion associated with water exchange have been cited as a barrier to its widespread use. To assess the feasibility of learning and using the water exchange method of colonoscopy in a U.S. community practice setting. Quality improvement program in nonacademic community endoscopy centers. Patients undergoing sedated diagnostic, surveillance, or screening colonoscopy. After direct coaching by a knowledgeable trainer, an experienced colonoscopist initiated colonoscopy using the water method. Whenever >5 min elapsed without advancing the colonoscope, conversion to air insufflation was made to ensure timely completion of the examination. Water Method Intention-to-treat (ITT) cecal intubation rate (CIR). Female patients had a significantly higher rate of past abdominal surgery and a significantly lower ITTCIR. The ITTCIR showed a progressive increase over time in both males and females to 85-90%. Mean insertion time was maintained at 9 to 10 min. The overall CIR was 99%. Use of water exchange did not preclude cecal intubation upon conversion to usual air insufflation in sedated patients examined by an experienced colonoscopist. With practice ITTCIR increased over time in both male and female patients. Larger volumes of water exchanged were associated with higher ITTCIR and better quality scores of bowel preparation. The data suggest that learning water exchange by a busy colonoscopist in a community practice setting is feasible and outcomes conform to accepted quality standards.

  12. Focal Colonic FDG Activity with PET/CT: Guidelines for Recommendation of Colonoscopy

    International Nuclear Information System (INIS)

    Liu, Tianye; Behr, Spencer; Khan, Sana; Osterhoff, Robert; Aparici, Carina Mari

    2015-01-01

    Focal 18 F-fluorodeoxyglucose (FDG) colonic activity can be incidentally seen in positron emission tomography/computed tomography (PET/CT) scans. Its clinical significance is still unclear. The purpose of this study was to assess the significance of focal FDG activity in PET/CT scans by correlating the imaging findings to colonoscopy results, and come up with some guidelines for recommendation of follow-up colonoscopy. A total of 133 patients who underwent both 18 F-FDG PET/CT for different oncological indications and colonoscopy within 3 months were retrospectively studied. Imaging, colonoscopy and pathology results were analyzed. Of the 133 FDG-PET/CT scans, 109/133 (82%) did not show focal colonic FDG activity, and 24/133 (18%) did. Of the 109/133 PET/CTs without focal colonic FDG activity, 109/109 (100%) did not have evidence of colon cancer after colonoscopy and histology. Of the 24/133 PET/CTs with focal colonic FDG activity, 10/24 (42%) had pathologic confirmation of colon cancer and 14/24 (58%) did not have evidence of colon cancer after colonoscopy and histological analysis. Sensitivity was 10/10 (100%), specificity 109/123 (89%), positive predictive value (PPV) 10/24 (42%) and negative predictive value (NPV) 109/109 (100%). Incidental focal 18 FDG activity in PET/CT imaging shows a high sensitivity, specificity and NPV for malignancy, with a not so high PPV of 42%. Although some people would argue that a 42% chance of malignancy justifies colonoscopy, this maybe is not possible in all cases. However, the high sensitivity of the test does not allow these studies to be overlooked. We provide our recommendations as per when to send patients with focal FDG colonic activity to have further characterization with colonoscopy

  13. Prospective Audit of Colonoscopy Practice in a Lebanese University Hospital

    Directory of Open Access Journals (Sweden)

    Rita Slim

    2008-01-01

    Full Text Available Background Colonoscopy has a great impact on diagnosis and management of the diseases of the colon. In general it's a safe and accurate procedure. No evaluation has been done of any endoscopic practices in a country where the practice of medicine is totally private. Objectives Prospective audit of technical success and complication rates of both therapeutic and diagnostic colonoscopy. Setting One endoscopy unit of a Lebanese university hospital. Patients and design 407 consecutive colonoscopies were evaluated over a 6-month period. Data were recorded for age and sex of the patients, indication of the colonoscopy, presence of comorbidities, patients risk stratification, administrated dose of anesthetic drugs. Data concerning the procedure itself were also monitored. Intervention Completion rate as well as complications reported during or post colonoscopy. All patients were called back by phone 48 hours and 1 month later to identify any related post-procedural complication. Results 407 patients underwent colonoscopy. All patients were sedated with midazolam, propofol and fentanyl. The overall caecal intubation rate was 99.99%. 70 snare polypectomies and 29 cold forceps excision were performed as well as 5 coagulations with Argon Plasma Coagulation. The most important post-procedural complication was chemical colitis in 2 cases. Limitations Patients and endoscopists satisfaction was not evaluated. It's an audit of a single tertiary French affiliated hospital. It does not necessarily reflect what's really happening on a national level. Conclusion This audit enabled us to change some of our practices; i.e. rinsing method of endoscopes. It stimulated the team to keep a high performance level without neglecting the risk of potential complications.

  14. Knowledge and attitudes of primary healthcare patients regarding population-based screening for colorectal cancer.

    Science.gov (United States)

    Ramos, Maria; Llagostera, Maria; Esteva, Magdalena; Cabeza, Elena; Cantero, Xavier; Segarra, Manel; Martín-Rabadán, Maria; Artigues, Guillem; Torrent, Maties; Taltavull, Joana Maria; Vanrell, Joana Maria; Marzo, Mercè; Llobera, Joan

    2011-09-25

    ABSTRACT: BACKGROUND: The aim of this study was to assess the extent of knowledge of primary health care (PHC) patients about colorectal cancer (CRC), their attitudes toward population-based screening for this disease and gender differences in these respects. METHODS: A questionnaire-based survey of PHC patients in the Balearic Islands and some districts of the metropolitan area of Barcelona was conducted. Individuals between 50 and 69 years of age with no history of CRC were interviewed at their PHC centers. RESULTS: We analyzed the results of 625 questionnaires, 58% of which were completed by women. Most patients believed that cancer diagnosis before symptom onset improved the chance of survival. More women than men knew the main symptoms of CRC. A total of 88.8% of patients reported that they would perform the fecal occult blood test (FOBT) for CRC screening if so requested by PHC doctors or nurses. If the FOBT was positive and a colonoscopy was offered, 84.9% of participants indicated that they would undergo the procedure, and no significant difference by gender was apparent. Fear of having cancer was the main reason for performance of an FOBT, and also for not performing the FOBT, especially in women. Fear of pain was the main reason for not wishing to undergo colonoscopy. Factors associated with reluctance to perform the FOBT were: (i) the idea that that many forms of cancer can be prevented by exercise and, (ii) a reluctance to undergo colonoscopy if an FOBT was positive. Factors associated with reluctance to undergo colonoscopy were: (i) residence in Barcelona, (ii) ignorance of the fact that early diagnosis of CRC is associated with better prognosis, (iii) no previous history of colonoscopy, and (iv) no intention to perform the FOBT for CRC screening. CONCLUSION: We identified gaps in knowledge about CRC and prevention thereof in PHC patients from the Balearic Islands and the Barcelona region of Spain. If fears about CRC screening, and CRC per se, are

  15. Knowledge and attitudes of primary healthcare patients regarding population-based screening for colorectal cancer

    Directory of Open Access Journals (Sweden)

    Torrent Maties

    2011-09-01

    Full Text Available Abstract Background The aim of this study was to assess the extent of knowledge of primary health care (PHC patients about colorectal cancer (CRC, their attitudes toward population-based screening for this disease and gender differences in these respects. Methods A questionnaire-based survey of PHC patients in the Balearic Islands and some districts of the metropolitan area of Barcelona was conducted. Individuals between 50 and 69 years of age with no history of CRC were interviewed at their PHC centers. Results We analyzed the results of 625 questionnaires, 58% of which were completed by women. Most patients believed that cancer diagnosis before symptom onset improved the chance of survival. More women than men knew the main symptoms of CRC. A total of 88.8% of patients reported that they would perform the fecal occult blood test (FOBT for CRC screening if so requested by PHC doctors or nurses. If the FOBT was positive and a colonoscopy was offered, 84.9% of participants indicated that they would undergo the procedure, and no significant difference by gender was apparent. Fear of having cancer was the main reason for performance of an FOBT, and also for not performing the FOBT, especially in women. Fear of pain was the main reason for not wishing to undergo colonoscopy. Factors associated with reluctance to perform the FOBT were: (i the idea that that many forms of cancer can be prevented by exercise and, (ii a reluctance to undergo colonoscopy if an FOBT was positive. Factors associated with reluctance to undergo colonoscopy were: (i residence in Barcelona, (ii ignorance of the fact that early diagnosis of CRC is associated with better prognosis, (iii no previous history of colonoscopy, and (iv no intention to perform the FOBT for CRC screening. Conclusion We identified gaps in knowledge about CRC and prevention thereof in PHC patients from the Balearic Islands and the Barcelona region of Spain. If fears about CRC screening, and CRC per se

  16. Mechanical analysis of insertion problems and pain during colonoscopy: why highly skill-dependent colonoscopy routines are necessary in the first place... and how they may be avoided

    NARCIS (Netherlands)

    Loeve, Arjo J.; Fockens, Paul; Breedveld, Paul

    2013-01-01

    Colonoscopy requires highly skill-dependent manoeuvres that demand a significant amount of training, and can cause considerable discomfort to patients, which increases the use of sedatives. Understanding the underlying fundamental mechanics behind insertion difficulties and pain during colonoscopy

  17. Haptic interface of the KAIST-Ewha colonoscopy simulator II.

    Science.gov (United States)

    Woo, Hyun Soo; Kim, Woo Seok; Ahn, Woojin; Lee, Doo Yong; Yi, Sun Young

    2008-11-01

    This paper presents an improved haptic interface for the Korea Advanced Institute of Science and Technology Ewha Colonoscopy Simulator II. The haptic interface enables the distal portion of the colonoscope to be freely bent while guaranteeing sufficient workspace and reflective forces for colonoscopy simulation. Its force-torque sensor measures the profiles of the user. Manipulation of the colonoscope tip is monitored by four deflection sensors and triggers computations to render accurate graphic images corresponding to the rotation of the angle knob. Tack sensors are attached to the valve-actuation buttons of the colonoscope to simulate air injection or suction as well as the corresponding deformation of the colon. A survey study for face validation was conducted, and the result shows that the developed haptic interface provides realistic haptic feedback for colonoscopy simulations.

  18. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn's Disease.

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-04-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn's disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-valuewomen with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease.

  19. Product of the SNPP VIIRS SD Screen Transmittance and the SD BRDF (RSB) From Both Yaw Maneuver and Regular On-Orbit Data

    Science.gov (United States)

    Lei, Ning; Xiong, Xiaoxiong

    2016-01-01

    To assure data quality, the Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) regularly performs on-orbit radiometric calibrations of its 22 spectral bands. The primary calibration radiance source for the reflective solar bands (RSBs) is a sunlit solar diffuser (SD). During the calibration process, sunlight goes through a perforated plate (the SD screen) and then strikes the SD. The SD scattered sunlight is used for the calibration, with the spectral radiance proportional to the product of the SD screen transmittance and the SD bidirectional reflectance distribution function (BRDF). The BRDF is decomposed to the product of its value at launch and a numerical factor quantifying its change since launch. Therefore, the RSB calibration requires accurate knowledge of the product of the SD screen transmittance and the BRDF (RSB; launch time). Previously, we calculated the product with yaw maneuver data and found that the product had improved accuracy over the prelaunch one. With both yaw maneuver and regular on orbit data, we were able to improve the accuracy of the SDSM screen transmittance and the product for the solar diffuser stability monitor SD view. In this study, we use both yaw maneuver and a small portion of regular on-orbit data to determine the product for the RSB SD view.

  20. Effects of Promotional Materials on Attitudes and Fear towards Colorectal Cancer Screening among Chinese Older Adults: An Experimental Study.

    Science.gov (United States)

    Leung, Doris Y P; Chen, Joanne M T; Lou, Vivian W Q; Wong, Eliza M L; Chan, Aileen W K; So, Winnie K W; Chan, Carmen W H

    2017-07-13

    Colorectal cancer (CRC) screening is a cost-effective prevention and control strategy. However, the promotion of CRC screening for older adults may be difficult because reading CRC prevention information may evoke embarrassment, fear, and anxiety towards the screening procedure and cancer diagnosis. This study aims to (1) examine the effects of three promotional materials for CRC screening on the attitudes toward CRC screening tests (screening interest, screening effectiveness, and trust in the screening results) and cancer fear, and (2) to explore the interaction effect of cancer fear with screening effectiveness and trust in the screening results on screening interest of the three screening tests (fecal occult blood test (FOBT), flexible sigmoidoscopy, and colonoscopy) among Chinese older adults. A total of 114 community-dwelling older adults were asked to look at the corresponding promotional materials (pamphlet, cartoon, and video) of one of the three study groups. The pamphlet and video represent convention strategies and the cartoon represents an innovative strategy. No significant difference was observed in the screening interest and cancer fear across groups. FOBT was the most preferred screening modality. The video group has a large proportion agreed screening effectiveness of flexible sigmoidoscopy than pamphlet and cartoon groups and trusted in the screening results for FOBT and flexible sigmoidoscopy than the pamphlet group. Logistic regression results showed that the effect of trust in the screening results on screening interest for colonoscopy was greater among participants with higher cancer fear than those with lower cancer fear level. In conclusion, the three promotional groups had produced similar results in their attitudes toward CRC screening and cancer fear. The use of cartoons may be a comparable approach with conventional methods in the promotion of CRC screening. Additional components that can arouse fear and boost response efficacy

  1. Pneumoperitoneum after virtual colonoscopy: causes, risk factors, and management.

    Science.gov (United States)

    Baccaro, Leopoldo M; Markelov, Alexey; Wilhelm, Jakub; Bloch, Robert

    2014-06-01

    Computed tomographic virtual colonoscopy (CTVC) is a safe and minimally invasive modality when compared with fiberoptic colonoscopy for evaluating the colon and rectum. We have reviewed the risks for colonic perforation by investigating the relevant literature. The objectives of this study were to assess the risk of colonic perforation during CTVC, describe risk factors, evaluate ways to reduce the incidence complications, and to review management and treatment options. A formal search of indexed publications was performed through PubMed. Search queries using keywords "CT colonography," "CT virtual colonoscopy," "virtual colonoscopy," and "perforation" yielded a total of 133 articles. A total of eight case reports and four review articles were selected. Combining case reports and review articles, a total of 25 cases of colonic perforation after CTVC have been reported. Causes include, but are not limited to, diverticular disease, irritable bowel diseases, obstructive processes, malignancies, and iatrogenic injury. Both operative and nonoperative management has been described. Nonoperative management has been proven safe and successful in minimally symptomatic and stable patients. Colonic perforation after CTVC is a rare complication and very few cases have been reported. Several risk factors are recurrent in the literature and must be acknowledged at the time of the study. Management options vary and should be tailored to each individual patient.

  2. Impact of patient education on quality of bowel preparation in outpatient colonoscopies.

    Science.gov (United States)

    Modi, Chintan; Depasquale, Joseph R; Digiacomo, W Scott; Malinowski, Judith E; Engelhardt, Kristen; Shaikh, Sohail N; Kothari, Shivangi T; Kottam, Raghu; Shakov, Rada; Maksoud, Charbel; Baddoura, Walid J; Spira, Robert S

    2009-01-01

    High-quality bowel preparation is essential for successful outpatient colonoscopy. Currently, the rate of adequate bowel preparation for outpatient colonoscopy in the USA is low. Patients often fail to adhere to recommended preparation instructions. Limited literature exists on evaluating educational intervention as a means of improving the quality of bowel preparation prior to outpatient colonoscopy. Our objective was to determine the effect of an educational intervention on the quality of outpatient colonoscopy preparation. The secondary objective was to determine whether the quality of bowel preparation improves overall colonoscopy outcomes as measured by rate of polyp detection and caecal intubation time. A single-blinded, prospective, randomised, controlled trial was conducted in two inner-city gastroenterology clinics in the USA. One hundred and sixty-four subjects were enrolled and randomly assigned to one of two groups. The control group subjects received verbal and written instructions for colonoscopy. The intervention group subjects received the same instructions and were then asked to answer a questionnaire. The subjects' responses were reviewed and an additional explanation of the preparation process provided. An attending gastroenterologist determined the quality of each bowel preparation at the time of colonoscopy using the Universal Preparation Assessment Scale. The educational intervention had no impact on the overall quality of bowel preparation (P=0.12). However, the type of food (liquid vs solid) consumed during the 24 hours prior to the procedure (P=0.04) and the time since the last solid meal (P=0.03) did have an impact on preparation quality. Other significant factors included elapsed time to first bowel movement from the initiation of bowel preparation (P=0.05) and age younger than 55 (P=0.02). Adequate bowel preparation was associated with shorter total procedure (P=0.001) and caecal intubation (P=0.01) times. Our study failed to demonstrate

  3. Assessment of colonoscopy by use of magnetic endoscopic imaging

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Preisler, Louise; Svendsen, Morten Bo Søndergaard

    2015-01-01

    and a difficult case. SETTING: Center for Clinical Education, Capital Region of Denmark. MAIN OUTCOME MEASUREMENTS: By using magnetic endoscopic imaging, we developed a colonoscopy progression score (CoPS). A pass/fail score was established by using the contrast-group method. RESULTS: We found significant...... differences in performance between the 2 groups using the CoPS in both case scenarios (easy: P heterogeneity of the experienced group resulted in a high passing score for the difficult case, which led to the failing of the less experienced...... in the group. The CoPS does not consider polyp detection rate, tissue damage, or patient discomfort. CONCLUSIONS: We developed a score of progression in colonoscopy, based on magnetic endoscopic imaging. With the same tool, a map of progression in colonoscopy can be provided. The CoPS and map of progression...

  4. Do Physician Recommendations for Colorectal Cancer Screening Differ by Patient Age?

    Directory of Open Access Journals (Sweden)

    Maida J Sewitch

    2007-01-01

    Full Text Available Colorectal cancer screening is underutilized, resulting in preventable morbidity and mortality. In the present study, age-related and other disparities associated with physicians’ delivery of colorectal cancer screening recommendations were examined. The present cross-sectional study included 43 physicians and 618 of their patients, aged 50 to 80 years, without past or present colorectal cancer. Of the 285 screen-eligible patients, 45% received a recommendation. Multivariate analyses revealed that, compared with younger nonde-pressed patients, older depressed patients were less likely to receive fecal occult blood test recommendations, compared with no recommendation (OR=0.31, 95% CI 0.09 to 1.02, as well as less likely to receive colonoscopy recommendations, compared with no recommendation (OR=0.14; 95% CI 0.03 to 0.66. Comorbidity and marital status were associated with delivery of fecal occult blood test and colonoscopy recommendations, respectively, compared with no recommendation. In summary, patient age and other characteristics appeared to influence physicians’ delivery of colorectal cancer screening and choice of modality.

  5. The effect of offering different numbers of colorectal cancer screening test options in a decision aid: a pilot randomized trial

    Directory of Open Access Journals (Sweden)

    Brenner Alison RT

    2008-01-01

    Full Text Available Abstract Background Decision aids can improve decision making processes, but the amount and type of information that they should attempt to communicate is controversial. We sought to compare, in a pilot randomized trial, two colorectal cancer (CRC screening decision aids that differed in the number of screening options presented. Methods Adults ages 48–75 not currently up to date with screening were recruited from the community and randomized to view one of two versions of our previously tested CRC screening decision aid. The first version included five screening options: fecal occult blood test (FOBT, sigmoidoscopy, a combination of FOBT and sigmoidoscopy, colonoscopy, and barium enema. The second discussed only the two most frequently selected screening options, FOBT and colonoscopy. Main outcomes were differences in screening interest and test preferences between groups after decision aid viewing. Patient test preference was elicited first without any associated out-of-pocket costs (OPC, and then with the following costs: FOBT-$10, sigmoidoscopy-$50, barium enema-$50, and colonoscopy-$200. Results 62 adults participated: 25 viewed the 5-option decision aid, and 37 viewed the 2-option version. Mean age was 54 (range 48–72, 58% were women, 71% were White, 24% African-American; 58% had completed at least a 4-year college degree. Comparing participants that viewed the 5-option version with participants who viewed the 2-option version, there were no differences in screening interest after viewing (1.8 vs. 1.9, t-test p = 0.76. Those viewing the 2-option version were somewhat more likely to choose colonoscopy than those viewing the 5-option version when no out of pocket costs were assumed (68% vs. 46%, p = 0.11, but not when such costs were imposed (41% vs. 42%, p = 1.00. Conclusion The number of screening options available does not appear to have a large effect on interest in colorectal cancer screening. The effect of offering differing

  6. Diverticular disease at colonoscopy in Lagos State, Nigeria.

    Science.gov (United States)

    Oluyemi, Aderemi; Odeghe, Emuobor

    2016-01-01

    The upsurge in the reported cases of diverticular disease (DD) has led to a re-appraisal of the earlier held views that it was a rare entity in Nigeria. The advent of colonoscopy has contributed in no small way to this change. We sought to determine the clinical characteristics, indications for colonoscopy, and intra-procedural findings among these patients. A retrospective cross-sectional study was carried out on the colonoscopy records from four private endoscopy units based in Lagos State, Nigeria. The records were drawn from a 5-year period (August 2010 to July 2015). The endoscopy logs and reports were reviewed, and the bio data, indications, and colonoscopy findings were gleaned. A total of 265 colonoscopies were carried out in the stated period. Of these, 28 (10.6%) had DD. Of the patients with DD, 5 (17.9%) were females while 23 (82.1%) were males. Their ages ranged from 46 to 94 years (mean = 68.2 ± 11 years). Fifteen patients had been referred for the procedure on account of hematochezia alone (15 = 53.6%). Other reasons for referral included abdominal pain alone (2 = 7%), hematochezia plus abdominal pain (5 = 17.9%), and change in bowel habits (3 = 10.8%). Ten (35%) patients had pan-colonic involvement. Regional disease involved the right side alone in only one case (3.5%) while the other combinations of sites are as follows; 6 (21.4%) in the sigmoid colon alone, 2 (7%) in the descending colon alone, 5 (17.9%) in the sigmoid-descending colon, 4 (14.3%) in the sigmoid-descending-transverse colon, thus the sigmoid colon was involved in 25 (89.3%) cases. Five cases (17.9%) had endoscopic features suggestive of diverticulitis. DD should no longer be regarded as a rare problem in the Nigerian patient. The study findings support the notion of higher prevalence among the elderly, in males, and of sigmoid colon involvement.

  7. Factors Associated with Anxiety About Colonoscopy: The Preparation, the Procedure, and the Anticipated Findings.

    Science.gov (United States)

    Shafer, L A; Walker, J R; Waldman, C; Yang, C; Michaud, V; Bernstein, C N; Hathout, L; Park, J; Sisler, J; Restall, G; Wittmeier, K; Singh, H

    2018-03-01

    Previous research has assessed anxiety around colonoscopy procedures, but has not considered anxiety related to different aspects related to the colonoscopy process. Before colonoscopy, we assessed anxiety about: bowel preparation, the procedure, and the anticipated results. We evaluated associations between patient characteristics and anxiety in each area. An anonymous survey was distributed to patients immediately prior to their outpatient colonoscopy in six hospitals and two ambulatory care centers in Winnipeg, Canada. Anxiety was assessed using a visual analog scale. For each aspect, logistic regression models were used to explore associations between patient characteristics and high anxiety. A total of 1316 respondents completed the questions about anxiety (52% female, median age 56 years). Anxiety scores > 70 (high anxiety) were reported by 18% about bowel preparation, 29% about the procedure, and 28% about the procedure results. High anxiety about bowel preparation was associated with female sex, perceived unclear instructions, unfinished laxative, and no previous colonoscopies. High anxiety about the procedure was associated with female sex, no previous colonoscopies, and confusing instructions. High anxiety about the results was associated with symptoms as an indication for colonoscopy and instructions perceived as confusing. Fewer people had high anxiety about preparation than about the procedure and findings of the procedure. There are unique predictors of anxiety about each colonoscopy aspect. Understanding the nuanced differences in aspects of anxiety may help to design strategies to reduce anxiety, leading to improved acceptance of the procedure, compliance with preparation instructions, and less discomfort with the procedure.

  8. What to Expect During a Colonoscopy

    Medline Plus

    Full Text Available ... Earn your CME from the convenience of your home or office by accessing ACG's web-based educational ... ACG Blog Follow ACG on Twitter Patients ACG Home / Media / What to Expect During a Colonoscopy What ...

  9. Socioeconomic and other predictors of colonoscopy preparation quality.

    Science.gov (United States)

    Lebwohl, Benjamin; Wang, Timothy C; Neugut, Alfred I

    2010-07-01

    Suboptimal bowel preparation prior to colonoscopy is a common occurrence, with a deleterious impact on colonoscopy effectiveness. Established risk factors for suboptimal bowel preparation have been proposed, but social factors, such as socioeconomic status and marital status, have not been investigated. The aim of this study was to evaluate sociodemographic factors, including insurance status and marital status, as predictive of suboptimal preparation. We analyzed a database of 12,430 consecutive colonoscopies during a 28-month period at Columbia University Medical Center. We collected the following variables: age, gender, indication for colonoscopy, location (inpatient vs. outpatient), race, marital status, and Medicaid status. Preparation quality was recorded and dichotomized as optimal or suboptimal. We employed multivariate regression to determine independent risk factors for suboptimal bowel preparation. Among the 10,921 examinations in which bowel preparation was recorded, suboptimal preparation occurred in 34% of Medicaid patients versus 18% of non-Medicaid patients (P Married patients had decreased rates of suboptimal preparation (OR 0.89, 95% CI 0.80-0.98). Other variables associated with suboptimal preparation included increased age (OR per 10 years 1.09, 95% CI 1.05-1.14), male gender (OR 1.44, 95% CI 1.31-1.59), inpatient status (OR 1.51, 95% CI 1.26-1.80), and later time of day (OR 1.89, 95% CI 1.71-2.09). Unmarried status and Medicaid status are predictive of suboptimal bowel preparation. Future studies are warranted to identify how these social conditions predict bowel preparation quality and to implement interventions to optimize bowel preparation in vulnerable populations.

  10. Stress perception among patients in pre-colonoscopy period and those undergoing chemotherapy treatment

    Directory of Open Access Journals (Sweden)

    Graziela de Souza Alves da Silva

    2015-05-01

    Full Text Available Objective: comparing the perception of stress among patients with colorectal cancer undergoing chemotherapy with those in pre-colonoscopy period. Methods: a comparative descriptive study developed with 144 people receiving chemotherapy and 100 patients in the pre-colonoscopy period, using biosocial and clinical data, Stress Assessment Tool and Perceived Stress Scale. Results: a predominance of females (73%, aged over 65 (50% were predominant for the pre-colonoscopy period patients. In patients receiving chemotherapy, gender parity with ages ranging from 40-64 years (68.1% was observed. Pre-colonoscopy patients showed higher perceived stress compared to those receiving chemotherapy (p <0.001. Conclusion: the phase of diagnostic definition represents greater stress to patients in comparison to period of treatment, even despite the characteristic manifestations of chemotherapy.

  11. Benefits of Barium Enema in Patients with Incomplete Colonoscopy. Prospective Study of 45 Cases

    International Nuclear Information System (INIS)

    Gispert, S.; Mayolas, N.; Hidalgo, A.

    2003-01-01

    To evaluate the usefulness of barium enema in patients with incomplete colonoscopy. There was carried out a prospective 10-month study of 45 patients with incomplete colonoscopy (27 men and 18 women), who were later examined by means of barium enema (33 conventional, 12 double-contrast) in order to check for additional pathology in portions of the colon not visualized by colonoscopy. Barium enema diagnosed six possible additional lesions (13.3%) in portions of the colon not visualized by incomplete colonoscopy (four neoplasia and two non-neoplasia). Regarding the neoplasia two were true positives and two false positives. Both true positives were adenocarcinomas (one synchronous caecum, and another in splenic angle). The two false positives corresponded to fecal matter stuck to the intestinal wall. Regarding the non-neoplasia, multiple stenosis was detected in a patient with Crohn's disease and an enterocolic fistula was found in a patient with sigmoid colon neoplasia. The diagnostic yield of barium enema in the detection of additional pathology in colon portions not visualized by colonoscopy was of 9%. Barium enema following incomplete colonoscopy permits a complete colon evaluation in most cases, and it offers additional diagnostic information. (Author) 21 refs

  12. Using Social Media to Characterize Public Sentiment Toward Medical Interventions Commonly Used for Cancer Screening: An Observational Study.

    Science.gov (United States)

    Metwally, Omar; Blumberg, Seth; Ladabaum, Uri; Sinha, Sidhartha R

    2017-06-07

    Although cancer screening reduces morbidity and mortality, millions of people worldwide remain unscreened. Social media provide a unique platform to understand public sentiment toward tools that are commonly used for cancer screening. The objective of our study was to examine public sentiment toward colonoscopy, mammography, and Pap smear and how this sentiment spreads by analyzing discourse on Twitter. In this observational study, we classified 32,847 tweets (online postings on Twitter) related to colonoscopy, mammography, or Pap smears using a naive Bayes algorithm as containing positive, negative, or neutral sentiment. Additionally, we characterized the spread of sentiment on Twitter using an established model to study contagion. Colonoscopy-related tweets were more likely to express negative than positive sentiment (negative to positive ratio 1.65, 95% CI 1.51-1.80, Psocial media data provides a unique, quantitative framework to better understand the public's perception of medical interventions that are commonly used for cancer screening. Given the growing use of social media, public health interventions to improve cancer screening should use the health perceptions of the population as expressed in social network postings about tests that are frequently used for cancer screening, as well as other people they may influence with such postings. ©Omar Metwally, Seth Blumberg, Uri Ladabaum, Sidhartha R. Sinha. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 07.06.2017.

  13. Current sedation and monitoring practice for colonoscopy: an International Observational Study (EPAGE)

    DEFF Research Database (Denmark)

    Froehlich, F; Harris, JK; Wietlisbach, V

    2006-01-01

    centers. Oxygen desaturation (LT /= 85 %) occurred in 5 % of patients, of whom 80 % were moderately sedated. On average, three staff members were involved in procedures. An anesthesiologist was present during 27 % of colonoscopies, and during 85 % of colonoscopies using deep sedation. CONCLUSIONS...

  14. Assessment of colonic disease by multi-slice CT pneumocolon after incomplete colonoscopy

    International Nuclear Information System (INIS)

    Zhao Zehua; Liu Wenjin; Xu Songsen; Wang Kang; Wang Weizhong

    2004-01-01

    Objective: To evaluate the use of preoperative MSCT in patients with clinically suspected colorectal disease after incomplete colonoscopy. Methods: After incomplete colonoscopy, 31 patients underwent MSCT before and after intravenous injection of iodinated contrast agent. CT virtual colonography (CTVC), multiplanar reformation (MPR), shaded surface display (SSD), and Raysum images were obtained by using 4 different software in workstation. The results of MSCT were compared with the findings of colonoscopy, intraoperative colon palpation, and postoperative pathology. Results: After incomplete colonoscopy, MSCT was successfully performed in all 31 cases. Postoperative pathology revealed 22 colorectal cancers (one synchronous cancers, two with polyps) and 9 benign disease. 22 colonic carcinomas were all correctly diagnosed by MSCT (including synchronous disease), 2 benign diseases were misdiagnosed as malignancy, and one polyp was missed. Conclusion: MSCT is a feasible and useful method for evaluating the entire colon before surgery in patients with occlusive disease. (author)

  15. Assessment of Jordanian Patient's Colorectal Cancer Awareness and Preferences towards CRC Screening: Are Jordanians Ready to Embrace CRC Screening?

    Science.gov (United States)

    Omran, Suha; Barakat, Husam; Muliira, Joshua Kanaabi; Bashaireh, Ibrahim; Batiha, Abdul-Moni'm

    2015-01-01

    Colorectal cancer (CRC is increasingly becoming a major cause of cancer morbidity and mortality in Jordan. However the population's level of awareness about CRC, CRC screening test preferences and willingness to embrace screening are not known. The aim of this study was to assess the level of CRC awareness and screening preferences among Jordanian patients. A survey assessing the CRC knowledge levels was distributed among patients attending outpatient gastroenterology clinics in public hospitals throughout Jordan. A total of 800 surveys were distributed and of these 713 (89.1%) were returned. Only 22% of the participants correctly judged CRC among the choices provided as the commonest cause of cancer related deaths. The majority of participants (68.3%) underestimated their risk for CRC. Only 26.8% correctly judged their life time risk while 5% overestimated their risk. Two thirds of participants (66%) were willing to pay 500 Jordanian Dinars (equivalent to 706 US$) in order to get a prompt colonoscopy if recommended by their physician, while 25.5% reported that they would rather wait for 6 months in order to get a free colonoscopy. Although the participants tended to underestimate their risk for CRC, they were mostly aware of CRC as a major cause of mortality and were willing to embrace the concept of CRC screening and bear the related financial costs. These findings about CRC awareness and propensity for screening provide a good foundation as the Jordanian health system moves forward with initiatives to promote CRC screening and prevention.

  16. Colorectal Cancer Surveillance after Index Colonoscopy: Guidance from the Canadian Association of Gastroenterology

    Directory of Open Access Journals (Sweden)

    Desmond Leddin

    2013-01-01

    Full Text Available BACKGROUND: Differences between American (United States [US] and European guidelines for colonoscopy surveillance may create confusion for the practicing clinician. Under- or overutilization of surveillance colonoscopy can impact patient care.

  17. The impact of diet liberalization on bowel preparation for colonoscopy

    OpenAIRE

    Walter, James; Francis, Gloria; Matro, Rebecca; Kedika, Ramalinga; Grosso, Rachael; Keith, Scott W.; Kastenberg, David

    2017-01-01

    Background and study aims?Dietary restrictions are integral to colonoscopy preparation and impact patient satisfaction. Utilizing split-dose, lower-volume polyethylene glycol 3350-electrolyte solution (PEG-ELS), this study compared colon preparation adequacy of a low-residue diet to clear liquids using a validated grading scale. Patients and methods?This was a prospective, randomized, single-blinded, single-center non-inferiority study evaluating diet the day prior to outpatient colonoscopy. ...

  18. Elimination of waste: creation of a successful Lean colonoscopy program at an academic medical center.

    Science.gov (United States)

    Damle, Aneel; Andrew, Nathan; Kaur, Shubjeet; Orquiola, Alan; Alavi, Karim; Steele, Scott R; Maykel, Justin

    2016-07-01

    Lean processes involve streamlining methods and maximizing efficiency. Well established in the manufacturing industry, they are increasingly being applied to health care. The objective of this study was to determine feasibility and effectiveness of applying Lean principles to an academic medical center colonoscopy unit. Lean process improvement involved training endoscopy personnel, observing patients, mapping the value stream, analyzing patient flow, designing and implementing new processes, and finally re-observing the process. Our primary endpoint was total colonoscopy time (minutes from check-in to discharge) with secondary endpoints of individual segment times and unit colonoscopy capacity. A total of 217 patients were included (November 2013-May 2014), with 107 pre-Lean and 110 post-Lean intervention. Pre-Lean total colonoscopy time was 134 min. After implementation of the Lean process, mean colonoscopy time decreased by 10 % to 121 min (p = 0.01). The three steps of the process affected by the Lean intervention (time to achieve adequate sedation, time to recovery, and time to discharge) decreased from 3.7 to 2.4 min (p Lean patient satisfaction surveys demonstrated an average score of 4.5/5.0 (n = 73) regarding waiting time, 4.9/5.0 (n = 60) regarding how favorably this experienced compared to prior colonoscopy experiences, and 4.9/5.0 (n = 74) regarding professionalism of staff. One hundred percentage of respondents (n = 69) stated they would recommend our institution to a friend for colonoscopy. With no additional utilization of resources, a single Lean process improvement cycle increased productivity and capacity of our colonoscopy unit. We expect this to result in increased patient access and revenue while maintaining patient satisfaction. We believe these results are widely generalizable to other colonoscopy units as well as other process-based interventions in health care.

  19. The Effect of Music on Pain, Anxiety and Vital Signs of Children during Colonoscopy

    Directory of Open Access Journals (Sweden)

    M Najafi

    2014-04-01

    Full Text Available Introduction: This study aimed to investigate the effect of music on pain, anxiety and vital signs in children undergoing colonoscopy.   Method and Materials: This randomized study was carried out on 101 children (7 to 14 years old requiring colonoscopy. Children were randomly allocated to a control or case group. The case group was played relaxing music (by Clayderman during the procedure. Spiegelberger and pain questionaires were administered immediately after the colonoscopy. Pulse rate, blood pressure and percent blood oxygen saturation were recorded for each subject. The control group was treated in an identical manner, but was not played music during the procedure. Data were analyzed using SPSS software.   Results: Satisfaction, anxiety, pain, and blood pressure were significantly different between the groups                (P0.05.   Conclusion: Music can reduce anxiety and pain during colonoscopy.   Key words: Anxiety, Music,Vital signs, Colonoscopy

  20. Evaluation of a fecal immunochemistry test prior to colonoscopy for outpatients with various indications

    Directory of Open Access Journals (Sweden)

    Szilagyi A

    2017-11-01

    Full Text Available Andrew Szilagyi,1 Xiaoqing Xue2 1Division of Gastroenterology, 2Division of Emergency Medicine, Jewish General Hospital, McGill University School of Medicine, Montreal, Quebec, Canada Background: Stool tests can predict advanced neoplasms prior to colonoscopy. Results of immunochemical stool tests to predict findings at colonoscopy for various indications are less often reported. We compared pre-colonoscopy stool tests with findings in patients undergoing colonoscopy for different indications. Patients and methods: Charts of patients undergoing elective or semi-urgent colonoscopy were reviewed. Comparison of adenoma detection rates and pathological findings was made between prescreened and non-prescreened, and between stool-positive and stool-negative cases. Demographics, quality of colonoscopy, and pathological findings were recorded. Odds ratios (ORs and 95% confidence intervals (CIs were assessed. Statistical significance was accepted at p≤0.05.Results: Charts of 325 patients were reviewed. Among them, stool tests were done on 144 patients: 114 were negative and 30 were positive. Findings were similar in the pretest and non-pretest groups. Detection of advanced adenomas per patient was higher in the stool-positive group compared to the stool-negative group (23.4% vs 3.5%, p=0.0016, OR =7.6 [95% CI: 2–29.3]. Five advanced adenomas (without high-grade dysplasia or adenocarcinoma and several cases of multiple adenomas were missed in the negative group. Sensitivity and specificity for advanced polyps was 63.6% and 82.7%, respectively. The negative predictive value was 96.5%. Male gender was independently predictive of any adenoma. Conclusion: The stool immunochemical test best predicted advanced neoplasms and had a high negative predictive value in this small cohort. Whether this test can be applied to determine the need for colonoscopy in groups other than average risk would require more studies. Keywords: fecal, blood, risks, colonoscopy

  1. Validation of the second-generation Olympus colonoscopy simulator for skills assessment.

    Science.gov (United States)

    Haycock, A V; Bassett, P; Bladen, J; Thomas-Gibson, S

    2009-11-01

    Simulators have potential value in providing objective evidence of technical skill for procedures within medicine. The aim of this study was to determine face and construct validity for the Olympus colonoscopy simulator and to establish which assessment measures map to clinical benchmarks of expertise. Thirty-four participants were recruited: 10 novices with no prior colonoscopy experience, 13 intermediate (trainee) endoscopists with fewer than 1000 previous colonoscopies, and 11 experienced endoscopists with more than 1000 previous colonoscopies. All participants completed three standardized cases on the simulator and experts gave feedback regarding the realism of the simulator. Forty metrics recorded automatically by the simulator were analyzed for their ability to distinguish between the groups. The simulator discriminated participants by experience level for 22 different parameters. Completion rates were lower for novices than for trainees and experts (37 % vs. 79 % and 88 % respectively, P variable stiffness function ( P = 0.004), number of sigmoid N-loops ( P = 0.02); size of sigmoid N-loops ( P = 0.01), and time to remove alpha loops ( P = 0.004). Out of 10, experts rated the realism of movement at 6.4, force feedback at 6.6, looping at 6.6, and loop resolution at 6.8. The Olympus colonoscopy simulator has good face validity and excellent construct validity. It provides an objective assessment of colonoscopic skill on multiple measures and benchmarks have been set to allow its use as both a formative and a summative assessment tool. Georg Thieme Verlag KG Stuttgart. New York.

  2. Syncope as the Presenting Feature of Splenic Rupture after Colonoscopy

    Directory of Open Access Journals (Sweden)

    Daniel Jamorabo

    2014-01-01

    Full Text Available Splenic rupture is a rare, catastrophic complication of colonoscopy and an exceptional cause of syncope. This injury is believed to be from direct trauma or tension on the splenocolic ligament with subsequent capsule avulsion or else from direct instrument-induced splenic injury. Diagnosis requires a high index of suspicion that may be absent because presentation can be subtle, nonspecific, and delayed anywhere from hours to days and therefore not easily attributed to a recent endoscopy. We describe a case of syncope as the initial manifestation of splenic rupture after colonoscopy. Our patient’s pain was delayed; his discomfort was mild and not localized to the left upper quadrant. Clinicians should consider syncope, lightheadedness, and drop in hemoglobin in absence of rectal bleeding following a colonoscopy as possible warning signs of imminent or emergent splenic injury.

  3. CT colonography versus colonoscopy in the follow-up of patients after diverticulitis - A prospective, comparative study

    International Nuclear Information System (INIS)

    Hjern, F.; Jonas, E.; Holmstroem, B.; Josephson, T.; Mellgren, A.; Johansson, C.

    2007-01-01

    Aim: To assess whether computed tomography colonography (CTC) is a viable alternative to colonoscopy or double contrast barium enema in the follow-up of patients after diverticulitis. Material and methods: Fifty patients underwent CTC followed immediately by colonoscopy. Results were blinded to the examiners. Findings of diverticular disease and patient acceptance were evaluated. Results: Bowel preparation and distension were good in the majority of CTC and colonoscopy examinations. Diverticular disease was found in 96% of patients at CTC and in 90% at colonoscopy. The rate of agreement between CTC and colonoscopy for diverticular findings in the sigmoid colon was good (κ = 0.64). No complications were seen. Patients found colonoscopy more uncomfortable (p < 0.03), more painful (p < 0.001), and more difficult (p < 0.01) than CTC. Of the patients favouring one examination, 74% preferred CTC. Conclusion: CTC appears to have a better diagnostic potential for imaging of diverticular disease-specific findings, when compared with colonoscopy. Also, CTC was less uncomfortable and was preferred by a majority of patients. CTC seems to be a reasonable alternative in follow-up of patients with symptomatic diverticular disease

  4. Can missed breast cancer be recognized by regular peer auditing on screening mammography?

    Science.gov (United States)

    Pan, Huay-Ben; Yang, Tsung-Lung; Hsu, Giu-Cheng; Chiang, Chia-Ling; Huang, Jer-Shyung; Chou, Chen-Pin; Wang, Yen-Chi; Liang, Huei-Lung; Lee, San-Kan; Chou, Yi-Hong; Wong, Kam-Fai

    2012-09-01

    This study was conducted to investigate whether detectable missed breast cancers could be distinguished from truly false negative images in a mammographic screening by a regular peer auditing. Between 2004 and 2007, a total of 311,193 free nationwide biennial mammographic screenings were performed for 50- to 69-year-old women in Taiwan. Retrospectively comparing the records in Taiwan's Cancer registry, 1283 cancers were detected (4.1 per 1000). Of the total, 176 (0.6 per 1000) initial mammographic negative assessments were reported to have cancers (128 traditional films and 48 laser-printed digital images). We selected 186 true negative films (138 traditional films and 48 laser-printed ones) as control group. These were seeded into 4815 films of 2008 images to be audited in 2009. Thirty-four auditors interpreted all the films in a single-blind, randomized, pair-control study. The performance of 34 auditors was analyzed by chi-square test. A p value of auditing should reduce the probability of missed cancers. 2012 Published by Elsevier B.V

  5. 2017 WSES guidelines for the management of iatrogenic colonoscopy perforation

    OpenAIRE

    de’Angelis, Nicola; Di Saverio, Salomone; Chiara, Osvaldo; Sartelli, Massimo; Martínez-Pérez, Aleix; Patrizi, Franca; Weber, Dieter G.; Ansaloni, Luca; Biffl, Walter; Ben-Ishay, Offir; Bala, Miklosh; Brunetti, Francesco; Gaiani, Federica; Abdalla, Solafah; Amiot, Aurelien

    2018-01-01

    Iatrogenic colonoscopy perforation (ICP) is a severe complication that can occur during both diagnostic and therapeutic procedures. Although 45–60% of ICPs are diagnosed by the endoscopist while performing the colonoscopy, many ICPs are not immediately recognized but are instead suspected on the basis of clinical signs and symptoms that occur after the endoscopic procedure. There are three main therapeutic options for ICPs: endoscopic repair, conservative therapy, and surgery. The therapeutic...

  6. Evaluation of a fecal immunochemistry test prior to colonoscopy for outpatients with various indications.

    Science.gov (United States)

    Szilagyi, Andrew; Xue, Xiaoqing

    2017-01-01

    Stool tests can predict advanced neoplasms prior to colonoscopy. Results of immunochemical stool tests to predict findings at colonoscopy for various indications are less often reported. We compared pre-colonoscopy stool tests with findings in patients undergoing colonoscopy for different indications. Charts of patients undergoing elective or semi-urgent colonoscopy were reviewed. Comparison of adenoma detection rates and pathological findings was made between prescreened and non-prescreened, and between stool-positive and stool-negative cases. Demographics, quality of colonoscopy, and pathological findings were recorded. Odds ratios (ORs) and 95% confidence intervals (CIs) were assessed. Statistical significance was accepted at p ≤0.05. Charts of 325 patients were reviewed. Among them, stool tests were done on 144 patients: 114 were negative and 30 were positive. Findings were similar in the pretest and non-pretest groups. Detection of advanced adenomas per patient was higher in the stool-positive group compared to the stool-negative group (23.4% vs 3.5%, p =0.0016, OR =7.6 [95% CI: 2-29.3]). Five advanced adenomas (without high-grade dysplasia or adenocarcinoma) and several cases of multiple adenomas were missed in the negative group. Sensitivity and specificity for advanced polyps was 63.6% and 82.7%, respectively. The negative predictive value was 96.5%. Male gender was independently predictive of any adenoma. The stool immunochemical test best predicted advanced neoplasms and had a high negative predictive value in this small cohort. Whether this test can be applied to determine the need for colonoscopy in groups other than average risk would require more studies.

  7. Chronic methadone use, poor bowel visualization and failed colonoscopy: A preliminary study

    Science.gov (United States)

    Verma, Siddharth; Fogel, Joshua; Beyda, David J; Bernstein, Brett; Notar-Francesco, Vincent; Mohanty, Smruti R

    2012-01-01

    AIM: To examine effects of chronic methadone usage on bowel visualization, preparation, and repeat colonoscopy. METHODS: In-patient colonoscopy reports from October, 2004 to May, 2009 for methadone dependent (MD) patients were retrospectively evaluated and compared to matched opioid naive controls (C). Strict criteria were applied to exclude patients with risk factors known to cause constipation or gastric dysmotility. Colonoscopy reports of all eligible patients were analyzed for degree of bowel visualization, assessment of bowel preparation (good, fair, or poor), and whether a repeat colonoscopy was required. Bowel visualization was scored on a 4 point scale based on multiple prior studies: excellent = 1, good = 2, fair = 3, or poor = 4. Analysis of variance (ANOVA) and Pearson χ2 test were used for data analyses. Subgroup analysis included correlation between methadone dose and colonoscopy outcomes. All variables significantly differing between MD and C groups were included in both univariate and multivariate logistic regression analyses. P values were two sided, and < 0.05 were considered statistically significant. RESULTS: After applying exclusionary criteria, a total of 178 MD patients and 115 C patients underwent a colonoscopy during the designated study period. A total of 67 colonoscopy reports for MD patients and 72 for C were included for data analysis. Age and gender matched controls were randomly selected from this population to serve as controls in a numerically comparable group. The average age for MD patients was 52.2 ± 9.2 years (range: 32-72 years) years compared to 54.6 ± 15.5 years (range: 20-81 years) for C (P = 0.27). Sixty nine percent of patients in MD and 65% in C group were males (P = 0.67). When evaluating colonoscopy reports for bowel visualization, MD patients had significantly greater percentage of solid stool (i.e., poor visualization) compared to C (40.3% vs 6.9%, P < 0.001). Poor bowel preparation (35.8% vs 9.7%, P < 0.001) and

  8. Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience

    International Nuclear Information System (INIS)

    Karcaaltincaba, M.; Karaosmanoglu, D.; Akata, D.; Sentuerk, S.; Oezmen, M.; Alibek, S.

    2009-01-01

    Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the absence of enhancement when compared to prone CT images. The major advantage of DE colonoscopy was the lack of misregistration. Conclusion: DE MDCT colonoscopy is technically feasible and may obviate the need for unenhanced prone images. It may be possible to perform noncathartic DECT colonoscopy. The major limitation is the limited FOV of tube B. The dose should be optimized to reduce streak artifacts in the pelvic region. (orig.)

  9. Medical image of the week: Boerhaave's syndrome during colonoscopy

    Directory of Open Access Journals (Sweden)

    Meenakshisundaram C

    2015-07-01

    Full Text Available No abstract available. Article truncated at 150 words. A 76-year-old woman with no significant past medical history underwent outpatient screening colonoscopy. The procedure was difficult due to a tortuous colon and only multiple diverticula were visualized. She vomited once during the procedure. In the immediate postoperative period, she complained of neck swelling. Her vital signs were stable. On examination, right sided neck and facial swelling with palpable crepitations were noticed as well as coarse breath sounds heard on auscultation of both lung fields. Immediate chest X-ray (Figure 1 was obtained which showed bilateral subcutaneous emphysema extending from the supraclavicular area and above to the neck. Subsequent thoracic CT scan showed extensive subcutaneous air within the soft tissues of the neck bilaterally, extending into the mediastinum and along the anterior chest wall (Figure 2. An esophagram (Figure 3 revealed a focus of oral contrast actively extravasating approximately at 2.5 cm above the gastro-esophageal junction consistent with a small perforation ...

  10. Risk Stratification and Shared Decision Making for Colorectal Cancer Screening: A Randomized Controlled Trial.

    Science.gov (United States)

    Schroy, Paul C; Duhovic, Emir; Chen, Clara A; Heeren, Timothy C; Lopez, William; Apodaca, Danielle L; Wong, John B

    2016-05-01

    Eliciting patient preferences within the context of shared decision making has been advocated for colorectal cancer (CRC) screening, yet providers often fail to comply with patient preferences that differ from their own. To determine whether risk stratification for advanced colorectal neoplasia (ACN) influences provider willingness to comply with patient preferences when selecting a desired CRC screening option. Randomized controlled trial. Asymptomatic, average-risk patients due for CRC screening in an urban safety net health care setting. Patients were randomized 1:1 to a decision aid alone (n= 168) or decision aid plus risk assessment (n= 173) arm between September 2012 and September 2014. The primary outcome was concordance between patient preference and test ordered; secondary outcomes included patient satisfaction with the decision-making process, screening intentions, test completion rates, and provider satisfaction. Although providers perceived risk stratification to be useful in selecting an appropriate screening test for their average-risk patients, no significant differences in concordance were observed between the decision aid alone and decision aid plus risk assessment groups (88.1% v. 85.0%,P= 0.40) or high- and low-risk groups (84.5% v. 87.1%,P= 0.51). Concordance was highest for colonoscopy and relatively low for tests other than colonoscopy, regardless of study arm or risk group. Failure to comply with patient preferences was negatively associated with satisfaction with the decision-making process, screening intentions, and test completion rates. Single-institution setting; lack of provider education about the utility of risk stratification into their decision making. Providers perceived risk stratification to be useful in their decision making but often failed to comply with patient preferences for tests other than colonoscopy, even among those deemed to be at low risk of ACN. © The Author(s) 2016.

  11. What is the diagnostic yield of colonoscopy in patients with a referral ...

    African Journals Online (AJOL)

    Eighty seven (60.4%) patients had a normal colonoscopy, 20 (13.9%) diverticular disease, 14 (9.7%) polyps of which 6 (4.2%) were neoplastic, and 9 (6.3%) had colorectal cancer. Conclusions: Constipation is associated with CRC. The presence of constipation should be a criterion for colonoscopy regardless of age or any ...

  12. Helicobacter pylori infection is an independent risk factor of early and advanced colorectal neoplasm.

    Science.gov (United States)

    Kim, Tae Jun; Kim, Eun Ran; Chang, Dong Kyung; Kim, Young-Ho; Baek, Sun-Young; Kim, Kyunga; Hong, Sung Noh

    2017-06-01

    The role of Helicobacter pylori (H. pylori) in the development of colorectal neoplasm remains controversial. We examined the association between H. pylori infection and colorectal neoplasm in a large sample of healthy participants who underwent screening colonoscopy. A cross-sectional study of 8916 men, who participated in a regular health-screening examination that included an H. pylori-specific immunoglobulin G antibody test and colonoscopy, was conducted to evaluate the association between H. pylori and colorectal neoplasm. Multivariable analyses adjusted for age, body mass index, smoking status, alcohol intake, regular exercise, regular aspirin use, and family history of colorectal cancer showed that the odds ratio (OR) (95% confidence interval [CI]) for any adenoma and advanced neoplasm was 1.32 (1.07-1.61) and 1.90 (1.05-3.56) in participants with H. pylori infection and without H. pylori infection, respectively. The association persisted after further adjustment for inflammatory markers or metabolic variables including fasting blood glucose, triglycerides, high-density lipoprotein-cholesterol, and low-density lipoprotein-cholesterol. Regarding the location, a positive association was confined to cases with proximal adenomas and was observed similarly in all the evaluated subgroups. In a large-scale study, carefully controlled for confounding factors, involving asymptomatic participants without a history of colonoscopy, H. pylori infection was significantly associated with the risk of any colorectal adenoma and advanced colorectal neoplasm. Prospective studies are necessary to determine whether H. pylori eradication can reduce this risk. © 2017 John Wiley & Sons Ltd.

  13. A Case of Taenia asiatica Infection Diagnosed by Colonoscopy.

    Science.gov (United States)

    Kim, Heung Up; Chung, Young-Bae

    2017-02-01

    A case of Taenia asiatica infection detected by small bowel series and colonoscopy is described. The patient was a 42-year-old Korean man accompanied by discharge of movable proglottids via anus. He used to eat raw pig liver but seldom ate beef. Small bowel series radiologic examinations showed flat tape-like filling defects on the ileum. By colonoscopy, a moving flat tapeworm was observed from the terminal ileum to the ascending colon. The tapeworm was identified as T. asiatica by mitochondrial DNA sequencing. The patient was prescribed with a single oral dose (16 mg/kg) of praziquantel.

  14. Cost analysis of colorectal cancer screening with CT colonography in Italy.

    Science.gov (United States)

    Mantellini, Paola; Lippi, Giuseppe; Sali, Lapo; Grazzini, Grazia; Delsanto, Silvia; Mallardi, Beatrice; Falchini, Massimo; Castiglione, Guido; Carozzi, Francesca Maria; Mascalchi, Mario; Milani, Stefano; Ventura, Leonardo; Zappa, Marco

    2018-06-01

    Unit costs of screening CT colonography (CTC) can be useful for cost-effectiveness analyses and for health care decision-making. We evaluated the unit costs of CTC as a primary screening test for colorectal cancer in the setting of a randomized trial in Italy. Data were collected within the randomized SAVE trial. Subjects were invited to screening CTC by mail and requested to have a pre-examination consultation. CTCs were performed with 64- and 128-slice CT scanners after reduced or full bowel preparation. Activity-based costing was used to determine unit costs per-process, per-participant to screening CTC, and per-subject with advanced neoplasia. Among 5242 subjects invited to undergo screening CTC, 1312 had pre-examination consultation and 1286 ultimately underwent CTC. Among 129 subjects with a positive CTC, 126 underwent assessment colonoscopy and 67 were ultimately diagnosed with advanced neoplasia (i.e., cancer or advanced adenoma). Cost per-participant of the entire screening CTC pathway was €196.80. Average cost per-participant for the screening invitation process was €17.04 and €9.45 for the pre-examination consultation process. Average cost per-participant of the CTC execution and reading process was €146.08 and of the diagnostic assessment colonoscopy process was €24.23. Average cost per-subject with advanced neoplasia was €3777.30. Cost of screening CTC was €196.80 per-participant. Our data suggest that the more relevant cost of screening CTC, amenable of intervention, is related to CTC execution and reading process.

  15. ACR Appropriateness Criteria® Colorectal Cancer Screening.

    Science.gov (United States)

    Moreno, Courtney; Kim, David H; Bartel, Twyla B; Cash, Brooks D; Chang, Kevin J; Feig, Barry W; Fowler, Kathryn J; Garcia, Evelyn M; Kambadakone, Avinash R; Lambert, Drew L; Levy, Angela D; Marin, Daniele; Peterson, Christine M; Scheirey, Christopher D; Smith, Martin P; Weinstein, Stefanie; Carucci, Laura R

    2018-05-01

    This review summarizes the relevant literature regarding colorectal screening with imaging. For individuals at average or moderate risk for colorectal cancer, CT colonography is usually appropriate for colorectal cancer screening. After positive results on a fecal occult blood test or immunohistochemical test, CT colonography is usually appropriate for colorectal cancer detection. For individuals at high risk for colorectal cancer (eg, hereditary nonpolyposis colorectal cancer, ulcerative colitis, or Crohn colitis), optical colonoscopy is preferred because of its ability to obtain biopsies to detect dysplasia. After incomplete colonoscopy, CT colonography is usually appropriate for colorectal cancer screening for individuals at average, moderate, or high risk. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Bowel preparations for colonoscopy: an RCT.

    Science.gov (United States)

    Di Nardo, Giovanni; Aloi, Marina; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Civitelli, Fortunata; Nuti, Federica; Ziparo, Chiara; Pession, Andrea; Lima, Mario; La Torre, Giuseppe; Oliva, Salvatore

    2014-08-01

    The ideal preparation regimen for pediatric colonoscopy remains elusive, and available preparations continue to represent a challenge for children. The aim of this study was to compare the efficacy, safety, tolerability, and acceptance of 4 methods of bowel cleansing before colonoscopy in children. This randomized, investigator-blinded, noninferiority trial enrolled all children aged 2 to 18 years undergoing elective colonoscopy in a referral center for pediatric gastroenterology. Patients were randomly assigned to receive polyethylene glycol (PEG) 4000 with simethicon (PEG-ELS group) or PEG-4000 with citrates and simethicone plus bisacodyl (PEG-CS+Bisacodyl group), or PEG 3350 with ascorbic acid (PEG-Asc group), or sodium picosulfate plus magnesium oxide and citric acid (NaPico+MgCit group). Bowel cleansing was evaluated according to the Boston Bowel Preparation Scale. The primary end point was overall colon cleansing. Tolerability, acceptability, and compliance were also evaluated. Two hundred ninety-nine patients were randomly allocated to the 4 groups. In the per-protocol analysis, PEG-CS+Bisacodyl, PEG-Asc, and NaPico+MgCit were noninferior to PEG-ELS in bowel-cleansing efficacy of both the whole colon (P = .910) and colonic segments. No serious adverse events occurred in any group. Rates of tolerability, acceptability, and compliance were significantly higher in the NaPico+MgCit group. Low-volume PEG preparations (PEG-CS+Bisacodyl, PEG-Asc) and NaPico+MgCit are noninferior to PEG-ELS in children, representing an attractive alternative to high-volume regimens in clinical practice. Because of the higher tolerability and acceptability profile, NaPico+MgCit would appear as the most suitable regimen for bowel preparation in children. Copyright © 2014 by the American Academy of Pediatrics.

  17. CMOST: an open-source framework for the microsimulation of colorectal cancer screening strategies.

    Science.gov (United States)

    Prakash, Meher K; Lang, Brian; Heinrich, Henriette; Valli, Piero V; Bauerfeind, Peter; Sonnenberg, Amnon; Beerenwinkel, Niko; Misselwitz, Benjamin

    2017-06-05

    Colorectal cancer (CRC) is a leading cause of cancer-related mortality. CRC incidence and mortality can be reduced by several screening strategies, including colonoscopy, but randomized CRC prevention trials face significant obstacles such as the need for large study populations with long follow-up. Therefore, CRC screening strategies will likely be designed and optimized based on computer simulations. Several computational microsimulation tools have been reported for estimating efficiency and cost-effectiveness of CRC prevention. However, none of these tools is publicly available. There is a need for an open source framework to answer practical questions including testing of new screening interventions and adapting findings to local conditions. We developed and implemented a new microsimulation model, Colon Modeling Open Source Tool (CMOST), for modeling the natural history of CRC, simulating the effects of CRC screening interventions, and calculating the resulting costs. CMOST facilitates automated parameter calibration against epidemiological adenoma prevalence and CRC incidence data. Predictions of CMOST were highly similar compared to a large endoscopic CRC prevention study as well as predictions of existing microsimulation models. We applied CMOST to calculate the optimal timing of a screening colonoscopy. CRC incidence and mortality are reduced most efficiently by a colonoscopy between the ages of 56 and 59; while discounted life years gained (LYG) is maximal at 49-50 years. With a dwell time of 13 years, the most cost-effective screening is at 59 years, at $17,211 discounted USD per LYG. While cost-efficiency varied according to dwell time it did not influence the optimal time point of screening interventions within the tested range. Predictions of CMOST are highly similar compared to a randomized CRC prevention trial as well as those of other microsimulation tools. This open source tool will enable health-economics analyses in for various countries

  18. Barriers to Colorectal Cancer Screening in Primary Care Settings: Attitudes and Knowledge of Nurses and Physicians

    Directory of Open Access Journals (Sweden)

    Joshua Kanaabi Muliira

    2016-01-01

    Full Text Available Objective: Healthcare providers (HCPs play a critical role in reducing colorectal cancer (CRC related morbidity and mortality. This study aimed at exploring the attitudes and knowledge of nurses and physicians working in primary care settings regarding CRC screening. Methods: A total of 142 HCPs (57.7% nurses and 42.3% physicians participated in a cross-sectional survey. Data were collected using a Self-administered Questionnaire. The participants were clinically experienced (mean = 9.39 years; standard deviation [SD] = 6.13, regularly taking care of adults eligible for CRC screening (62% and had positive attitudes toward CRC screening (83.1%. Most participants (57% had low levels of knowledge about CRC screening (mean = 3.23; SD = 1.50. The participants were most knowledgeable about the recommended age for initiating screening (62.7% and the procedures not recommended for screening (90.8%. Results: More than 55% did not know the frequency of performing specific screening procedures, the upper age limit at which screening is not recommended, and the patients at high-risk for CRC. There were no significant differences between nurses′ and physicians′ attitudes and knowledge. The participants′ perceptions about professional training (odds ratio [OR] = 2.17, P = 0.003, colonoscopy (OR = 2.60, P = 0.014, and double-contrast barium enema (OR = 0.53, P = 0.041, were significantly associated with knowledge about CRC screening. Conclusions: The inadequate knowledge levels among nurses and physicians may be one of the barriers affecting CRC screening. Enhancing HCPs knowledge about CRC screening should be considered a primary intervention in the efforts to promote CRC screening and prevention.

  19. Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy.

    Science.gov (United States)

    Valdastri, P; Ciuti, G; Verbeni, A; Menciassi, A; Dario, P; Arezzo, A; Morino, M

    2012-05-01

    Despite being considered the most effective method for colorectal cancer diagnosis, colonoscopy take-up as a mass-screening procedure is limited mainly due to invasiveness, patient discomfort, fear of pain, and the need for sedation. In an effort to mitigate some of the disadvantages associated with colonoscopy, this work provides a preliminary assessment of a novel endoscopic device consisting in a softly tethered capsule for painless colonoscopy under robotic magnetic steering. The proposed platform consists of the endoscopic device, a robotic unit, and a control box. In contrast to the traditional insertion method (i.e., pushing from behind), a "front-wheel" propulsion approach is proposed. A compliant tether connecting the device to an external box is used to provide insufflation, passing a flexible operative tool, enabling lens cleaning, and operating the vision module. To assess the diagnostic and treatment ability of the platform, 12 users were asked to find and remove artificially implanted beads as polyp surrogates in an ex vivo model. In vivo testing consisted of a qualitative study of the platform in pigs, focusing on active locomotion, diagnostic and therapeutic capabilities, safety, and usability. The mean percentage of beads identified by each user during ex vivo trials was 85 ± 11%. All the identified beads were removed successfully using the polypectomy loop. The mean completion time for accomplishing the entire procedure was 678 ± 179 s. No immediate mucosal damage, acute complications such as perforation, or delayed adverse consequences were observed following application of the proposed method in vivo. Use of the proposed platform in ex vivo and preliminary animal studies indicates that it is safe and operates effectively in a manner similar to a standard colonoscope. These studies served to demonstrate the platform's added advantages of reduced size, front-wheel drive strategy, and robotic control over locomotion and orientation.

  20. Predictors of advanced colorectal neoplasia for colorectal cancer screening.

    Science.gov (United States)

    Wong, Martin C S; Lam, Thomas Y T; Tsoi, Kelvin K F; Chan, Victor C W; Hirai, Hoyee W; Ching, Jessica Y L; Sung, Joseph J Y

    2014-05-01

    The Asia-Pacific Colorectal Screening (APCS) score based on age, gender, family history, and smoking is useful to predict advanced colorectal neoplasia (ACN) in asymptomatic Asian subjects. To evaluate the factors in addition to those of APCS associated with ACN colonoscopic findings. Data from 5,220 asymptomatic subjects aged between 50 and 70 years who underwent screening colonoscopy in a community center between 2008 and 2012 were analyzed. One binary logistic regression analysis was conducted in 2013 with the presence of ACN or cancer as the outcome, controlling for APCS score, alcohol consumption, BMI, hypertension, and other chronic diseases as independent variables. The average participant age was 57.7 years (SD=4.9) and 47.5% were men. Advanced neoplasms or cancers were identified at colonoscopy in 5.6% of all screening participants. From multivariate regression analysis, APCS score≥4 (adjusted OR [AOR]=1.74, 95% CI=1.34, 2.25, pstatistic of APCS score alone was 0.560 (95% CI=0.524, 0.595, p=0.001) and that of APCS score plus BMI, hypertension, and alcohol consumption was 0.613 (95% CI=0.578, 0.648, p<0.001). Alcohol consumption, hypertension, and BMI are independent predictors of ACN, which could be incorporated into the APCS for prioritizing Asian asymptomatic subjects for colorectal cancer screening. Copyright © 2014. Published by Elsevier Inc.

  1. The association between recreational physical activity, sedentary time, and colorectal polyps in a population screened for colorectal cancer.

    Science.gov (United States)

    Brenner, Darren R; Shaw, Eileen; Yannitsos, Demetra H; Warkentin, Matthew T; Brockton, Nigel T; McGregor, S Elizabeth; Town, Susanna; Hilsden, Robert J

    2018-04-01

    Regular recreational moderate to vigorous physical activity (rMVPA) has been previously associated with a reduced risk of colorectal cancer (CRC), however, few studies have examined the association of rMVPA with colorectal polyps, the pre-malignant precursor lesions. The objective of this study was to examine the associations between physical activity and sitting time and polyps at the time of screening. We conducted a cross-sectional study of 2496 individuals undergoing screening-related colonoscopy in Calgary, Alberta, Canada. Physical activity and sitting time were characterized using hours of rMVPA, meeting physical activity recommendations and hours of sitting time using self-reported data obtained from the International Physical Activity Questionnaire. Logistic regression models were used to estimate the crude and adjusted odds ratios (OR) for presence of polyps associated with rMVPA and sitting time. Meeting physical activity guidelines of ≥150 min/week was non-significantly associated with a modest decrease in odds of having ≥1 polyp at screening (OR adj  = 0.95, 95% CI: 0.80-1.14). In males, threshold effects for sitting time were observed for up to 20 h/week (OR adj per hour sitting = 1.07, 95% CI: 1.01-1.13). In stratified analysis, larger inverse associations were observed between physical activity and the presence of polyps in females, obese individuals, and ever smokers, compared to pooled findings. In this large CRC screening population, there was a suggestive association between increased rMVPA and reduced prevalence of polyps at screening, particularly among females. Even low amounts of regular sitting time (0-20 h/day) were associated with the presence of polyps, particularly among males. Further research on rMVPA and sitting time is necessary to better inform strategies to reduce the frequency of pre-malignant colorectal lesions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Evaluation of a patient navigation program to promote colorectal cancer screening in rural Georgia, USA.

    Science.gov (United States)

    Honeycutt, Sally; Green, Rhonda; Ballard, Denise; Hermstad, April; Brueder, Alex; Haardörfer, Regine; Yam, Jennifer; Arriola, Kimberly J

    2013-08-15

    Colorectal cancer (CRC) is a leading cause of cancer death in the United States. Early detection through recommended screening has been shown to have favorable treatment outcomes, yet screening rates among the medically underserved and uninsured are low, particularly for rural and minority populations. This study evaluated the effectiveness of a patient navigation program that addresses individual and systemic barriers to CRC screening for patients at rural, federally qualified community health centers. This quasi-experimental evaluation compared low-income patients at average risk for CRC (n = 809) from 4 intervention clinics and 9 comparison clinics. We abstracted medical chart data on patient demographics, CRC history and risk factors, and CRC screening referrals and examinations. Outcomes of interest were colonoscopy referral and examination during the study period and being compliant with recommended screening guidelines at the end of the study period. We conducted multilevel logistic analyses to evaluate the program's effectiveness. Patients at intervention clinics were significantly more likely than patients at comparison clinics to undergo colonoscopy screening (35% versus 7%, odds ratio = 7.9, P screening test (43% versus 11%, odds ratio = 5.9, P Screening Program, can be an effective approach to ensure that lifesaving, preventive health screenings are provided to low-income adults in a rural setting. Copyright © 2013 American Cancer Society.

  3. A comparison of different strategies used to invite subjects with a positive faecal occult blood test to a colonoscopy assessment. A randomised controlled trial in population-based screening programmes.

    Science.gov (United States)

    Zorzi, Manuel; Giorgi Rossi, Paolo; Cogo, Carla; Falcini, Fabio; Giorgi, Daniela; Grazzini, Grazia; Mariotti, Loretta; Matarese, Vincenzo; Soppelsa, Fabio; Senore, Carlo; Ferro, Antonio

    2014-08-01

    The purpose of this parallel randomised controlled trial was to compare compliance with different modalities used to invite patients with a positive immunochemical faecal occult blood test (FIT+) for a total colonoscopy (TC). FIT+ patients from nine Italian colorectal cancer screening programmes were randomised to be invited for a TC initially by mail or by phone and, for non-compliers, to be recalled by mail, for counselling with a general practitioner, or to meet with a specialist screening practitioner (nurse or healthcare assistant). In all, 3777 patients were randomised to different invitation strategies. Compliance with an initial invitation by mail and by phone was similar (86.0% vs. 84.0%, relative risk - RR: 1.02; 95%CI 0.97-1.08). Among non-responders to the initial invitation, compliance with a recall by appointment with a specialist practitioner was 50.4%, significantly higher than with a mail recall (38.1%; RR:1.33; 95%CI 1.01-1.76) or with a face-to-face counselling with the GP (30.8%; RR:1.45;95%CI 1.14-1.87). Compliance with an initial invitation for a TC by mail and by phone was similar. A personal meeting with a specialist screening practitioner was associated with the highest compliance among non-compliers with initial invitations, while the involvement of GPs in this particular activity seemed less effective. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The Diagnostic Role of Magnetic Resonance Enterography as a Complementary Test to Colonoscopy in Active Crohn’s Disease

    Science.gov (United States)

    Aryan, Arvin; Azizi, Zahra; Teimouri, Azam; Ebrahimi Daryani, Nasser; Aletaha, Najme; Jahanbakhsh, Ali; Nouritaromlou, Mohammad Kazem; Alborzi, Forough; Mami, Masoud; Basirat, Vahid; Javid Anbardan, Sanam

    2016-01-01

    BACKGROUND According to recent studies comparing magnetic resonance enterography (MRE) with ileocolonoscopy for assessing inflammation of small bowel and colonic segments in adults with active Crohn’s disease (CD), we aimed to compare the accuracy of these two diagnostic methods in Iranian population. METHODS During 2013-2014 a follow-up study was done on 30 patients with active CD in a gastroenterology clinic affiliated to Tehran University of Medical Sciences. MRE and ileocolonoscopy were performed for all the patients. All statistical analyses were performed using SPSS (version 18) and p-value<0.05 was considered as statistically significant. RESULTS Of the 30 patients with active CD, 11(36.7%) were men and 19 (63.3%) were women with mean age of 37.30±13.66 years (range: 19-67 years). MRE had sensitivity and specificity of 50% and 90% with positive predictive value (PPV) and negative predictive value (NPV) of 71.43 and 78.26, respectively for localizing sigmoid lesions and ileum had sensitivity and specificity of 84.21 and 45.45 with PPV and NPV of 72.73 and 62.50, respectively. CONCLUSION While moderate sensitivity and high specificity of MRE in localizing colonic lesions makes it an appropriate confirmatory test after colonoscopy, the reported high sensitivity and moderate specificity of MRE versus colonoscopy in detecting ileal lesions makes it a suitable screening test for ileal lesions. Finally we can conclude that MRE can be an important complementary test to colonoscopy in detecting active disease. PMID:27252815

  5. Withdrawal times and associated factors in colonoscopy: a quality assurance multicenter assessment.

    Science.gov (United States)

    Overholt, Bergein F; Brooks-Belli, Linda; Grace, Michael; Rankin, Kristin; Harrell, Royce; Turyk, Mary; Rosenberg, Fred B; Barish, Robert W; Gilinsky, Norman H

    2010-04-01

    To evaluate the use and impact of the recommended withdrawal time of at least 6 minutes from the cecum in colonoscopy in multiple gastroenterology endoscopy ambulatory surgery centers serving a wide geographical area. An observational prospective multicenter quality assurance review was conducted in 49 ambulatory surgery centers in 17 states with 315 gastroenterologists. There was no intervention with this quality assessment program as care of patients and the routine of gastroenterologists continued as standard practice. Multivariable analysis was applied to the database to examine factors affecting withdrawal time and polyp detection. There were 15,955 consecutive qualified patients receiving colonoscopies in a designated 4-week period. Gastroenterologists with average withdrawal times of 6 minutes or more in patients with no polyps were 1.8 times more likely to detect 1 or more polyps and had a significantly higher rate (Pquality assurance assessment from standard colonoscopy practices of 315 gastroenterologists in 49 endoscopic ambulatory surgery centers serving a wide geographical area provides support for the merits of a colonoscopy withdrawal time from the cecum of 6 minutes or more to improve the detection of polyps.

  6. One-day bowel preparation with polyethylene glycol 3350: an effective regimen for colonoscopy in children.

    Science.gov (United States)

    Adamiak, Tonya; Altaf, Muhammad; Jensen, Michael K; Sultan, Mutaz; Ramprasad, Jonathan; Ciecierega, Thomas; Sherry, Karen; Miranda, Adrian

    2010-03-01

    Polyethylene glycol (PEG) 3350 is commonly used and has been proven safe and effective for the treatment of chronic constipation and as a 4-day bowel preparation in children. A 1-day PEG 3350 bowel preparation regimen has been recently developed for adults; however, data regarding its use in children are lacking. To evaluate the safety and effectiveness of a 1-day PEG 3350 regimen for bowel preparation in children before colonoscopy. Retrospective review. Tertiary-care center. This study involved all children prescribed a 1-day PEG 3350 bowel preparation regimen before colonoscopy at our center in 2008. We reviewed medical records of patients (PEG 3350 preparation regimen was 13.7 years (range 1.08-17.92 years). Fifty-two percent were male; 48% were female. The most common indications for colonoscopy included abdominal pain (65%), bloody stools (29%), diarrhea (21%), and weight loss (18%). The 1-day bowel preparation regimen was effective in 253 patients (93%). The indication for colonoscopy, the age of the child, or a history of constipation did not significantly alter the success rate of colonoscopy. A retrospective study at one tertiary-care center. The 1-day PEG 3350 bowel preparation regimen is safe and effective and should be considered for use as preparation for colonoscopy in children. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  7. The relative importance of patient-reported barriers to colorectal cancer screening.

    Science.gov (United States)

    Jones, Resa M; Woolf, Steven H; Cunningham, Tina D; Johnson, Robert E; Krist, Alex H; Rothemich, Stephen F; Vernon, Sally W

    2010-05-01

    Colorectal cancer (CRC) screening rates are suboptimal. The most important barriers identified by patients are poorly understood. A comprehensive assessment of barriers to all recommended modalities is needed. In 2007, a questionnaire was mailed to 6100 patients, aged 50-75 years, from 12 family medicine practices in the Virginia Ambulatory Care Outcomes Research Network. People aged 65-75 years and African Americans were oversampled. Patients were asked to rate 19-21 barriers to each of four recommended tests. In 2008, responses were coded on a 5-point scale; higher scores reflected stronger barrier endorsement. The response rate was 55% (n=3357). Approximately 40% of respondents were aged >/=65 years, 30% were African-American, and 73% were adherent to screening. A clinician's failure to suggest screening and not knowing testing was necessary received the highest mean scores as barriers. Financial concerns and misconceptions were also cited. Barrier scores differed depending on whether respondents were never screened, overdue for screening, or adherent to guidelines. The top five barriers for each modality included test-specific barriers (e.g., handling stool, bowel preparation), which often outranked generic barriers to screening. Not knowing testing was necessary was a top barrier for all tests but colonoscopy. Although physician advice and awareness of the need for screening are important, barriers to screening are not homogenous across tests, and test-specific barriers warrant consideration in designing strategies to improve screening rates. Barrier scores differ by screening status, highlighting the need to address prior screening experience. Evidence that patients are more familiar with colonoscopy than with other modalities suggests an opportunity to improve screening rates by educating patients about alternative tests. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  8. Aromatherapy for reducing colonoscopy related procedural anxiety and physiological parameters: a randomized controlled study.

    Science.gov (United States)

    Hu, Pei-Hsin; Peng, Yen-Chun; Lin, Yu-Ting; Chang, Chi-Sen; Ou, Ming-Chiu

    2010-01-01

    Colonoscopy is generally tolerated, some patients regarding the procedure as unpleasant and painful and generally performed with the patient sedated and receiving analgesics. The effect of sedation and analgesia for colonoscopy is limited. Aromatherapy is also applied to gastrointestinal endoscopy to reduce procedural anxiety. There is lack of information about aromatherapy specific for colonoscopy. In this study, we aimed to performed a randomized controlled study to investigate the effect of aromatherapy on relieve anxiety, stress and physiological parameters of colonoscopy. A randomized controlled trail was carried out and collected in 2009 and 2010. The participants were randomized in two groups. Aromatherapy was then carried out by inhalation of Sunflower oil (control group) and Neroli oil (Experimental group). The anxiety index was evaluated by State Trait Anxiety Inventory-state (STAI-S) score before aromatherapy and after colonoscopy as well as the pain index for post-procedural by visual analogue scale (VAS). Physiological indicators, such as blood pressure (systolic and diastolic blood pressure), heart rate and respiratory rate were evaluated before and after aromatherapy. Participates in this study were 27 subjects, 13 in control group and 14 in Neroli group with average age 52.26 +/- 17.79 years. There was no significance of procedural anxiety by STAI-S score and procedural pain by VAS. The physiological parameters showed a significant lower pre- and post-procedural systolic blood pressure in Neroli group than control group. Aromatic care for colonoscopy, although with no significant effect on procedural anxiety, is an inexpensive, effective and safe pre-procedural technique that could decrease systolic blood pressure.

  9. Comorbid Illness, Bowel Preparation, and Logistical Constraints Are Key Reasons for Outpatient Colonoscopy Nonattendance

    Directory of Open Access Journals (Sweden)

    Deepti Chopra

    2016-01-01

    Full Text Available Background. Colonoscopy nonattendance is a challenge for outpatient clinics globally. Absenteeism results in a potential delay in disease diagnosis and loss of hospital resources. This study aims to determine reasons for colonoscopy nonattendance from a Canadian perspective. Design. Demographic data, reasons for nonattendance, and patient suggestions for improving compliance were elicited from 49 out of 144 eligible study participants via telephone questionnaire. The 49 nonattenders were compared to age and sex matched controls for several potential contributing factors. Results. Nonattendance rates were significantly higher in winter months; the OR of nonattendance was 5.2 (95% CI, 1.6 to 17.0, p<0.001 in winter versus other months. Being married was positively associated with attendance. There was no significant association between nonattendance and any of the other variables examined. The top 3 reasons for nonattendance were being too unwell to attend the procedure, being unable to complete bowel preparation, or experiencing logistical challenges. Conclusions. Colonoscopy attendance rates appear to vary significantly by season and it may be beneficial to book more colonoscopies in the summer or overbook in the winter. Targets for intervention include more tailored teaching sessions, reminders, taxi chits, and developing a hospital specific colonoscopy video regarding procedure and bowel preparation requirements.

  10. Computed tomographic colonography to screen for colorectal cancer, extracolonic cancer, and aortic aneurysm: model simulation with cost-effectiveness analysis.

    Science.gov (United States)

    Hassan, Cesare; Pickhardt, Perry J; Pickhardt, Perry; Laghi, Andrea; Kim, Daniel H; Kim, Daniel; Zullo, Angelo; Iafrate, Franco; Di Giulio, Lorenzo; Morini, Sergio

    2008-04-14

    In addition to detecting colorectal neoplasia, abdominal computed tomography (CT) with colonography technique (CTC) can also detect unsuspected extracolonic cancers and abdominal aortic aneurysms (AAA).The efficacy and cost-effectiveness of this combined abdominal CT screening strategy are unknown. A computerized Markov model was constructed to simulate the occurrence of colorectal neoplasia, extracolonic malignant neoplasm, and AAA in a hypothetical cohort of 100,000 subjects from the United States who were 50 years of age. Simulated screening with CTC, using a 6-mm polyp size threshold for reporting, was compared with a competing model of optical colonoscopy (OC), both without and with abdominal ultrasonography for AAA detection (OC-US strategy). In the simulated population, CTC was the dominant screening strategy, gaining an additional 1458 and 462 life-years compared with the OC and OC-US strategies and being less costly, with a savings of $266 and $449 per person, respectively. The additional gains for CTC were largely due to a decrease in AAA-related deaths, whereas the modeled benefit from extracolonic cancer downstaging was a relatively minor factor. At sensitivity analysis, OC-US became more cost-effective only when the CTC sensitivity for large polyps dropped to 61% or when broad variations of costs were simulated, such as an increase in CTC cost from $814 to $1300 or a decrease in OC cost from $1100 to $500. With the OC-US approach, suboptimal compliance had a strong negative influence on efficacy and cost-effectiveness. The estimated mortality from CT-induced cancer was less than estimated colonoscopy-related mortality (8 vs 22 deaths), both of which were minor compared with the positive benefit from screening. When detection of extracolonic findings such as AAA and extracolonic cancer are considered in addition to colorectal neoplasia in our model simulation, CT colonography is a dominant screening strategy (ie, more clinically effective and more cost

  11. Budget Impact Analysis of Against Colorectal Cancer In Our Neighborhoods (ACCION): A Successful Community-Based Colorectal Cancer Screening Program for a Medically Underserved Minority Population.

    Science.gov (United States)

    Kim, Bumyang; Lairson, David R; Chung, Tong Han; Kim, Junghyun; Shokar, Navkiran K

    2017-06-01

    Given the uncertain cost of delivering community-based cancer screening programs, we developed a Markov simulation model to project the budget impact of implementing a comprehensive colorectal cancer (CRC) prevention program compared with the status quo. The study modeled the impacts on the costs of clinical services, materials, and staff expenditures for recruitment, education, fecal immunochemical testing (FIT), colonoscopy, follow-up, navigation, and initial treatment. We used data from the Against Colorectal Cancer In Our Neighborhoods comprehensive CRC prevention program implemented in El Paso, Texas, since 2012. We projected the 3-year financial consequences of the presence and absence of the CRC prevention program for a hypothetical population cohort of 10,000 Hispanic medically underserved individuals. The intervention cohort experienced a 23.4% higher test completion rate for CRC prevention, 8 additional CRC diagnoses, and 84 adenomas. The incremental 3-year cost was $1.74 million compared with the status quo. The program cost per person was $261 compared with $86 for the status quo. The costs were sensitive to the proportion of high-risk participants and the frequency of colonoscopy screening and diagnostic procedures. The budget impact mainly derived from colonoscopy-related costs incurred for the high-risk group. The effectiveness of FIT to detect CRC was critically dependent on follow-up after positive FIT. Community cancer prevention programs need reliable estimates of the cost of CRC screening promotion and the added budget impact of screening with colonoscopy. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  12. Self-reported colorectal cancer screening of Medicare beneficiaries in family medicine vs. internal medicine practices in the United States: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Higgins Angela Y

    2012-03-01

    Full Text Available Abstract Background The benefit of screening for decreasing the risk of death from colorectal cancer (CRC has been shown, yet many patients in primary care are still not undergoing screening according to guidelines. There are known variations in delivery of preventive health care services among primary care physicians. This study compared self-reported CRC screening rates and patient awareness of the need for CRC screening of patients receiving care from family medicine (FPs vs. internal medicine (internists physicians. Methods Nationally representative sample of non-institutionalized beneficiaries who received medical care from FPs or internists in 2006 (using Medicare Current Beneficiary Survey. The main outcome was the percentage of patients screened in 2007. We also examined the percentage of patients offered screening. Results Patients of FPs, compared to those of internists, were less likely to have received an FOBT kit or undergone home FOBT, even after accounting for patients' characteristics. Compared to internists, FPs' patients were more likely to have heard of colonoscopy, but were less likely to receive a screening colonoscopy recommendation (18% vs. 27%, or undergo a colonoscopy (43% vs. 46%, adjusted odds ratios [AOR], 95% confidence interval [CI]-- 0.65, 0.51-0.81 or any CRC screening (52% vs. 60%, AOR, CI--0.80, 0.68-0.94. Among subgroups examined, higher income beneficiaries receiving care from internists had the highest screening rate (68%, while disabled beneficiaries receiving care from FPs had the lowest screening rate (34%. Conclusion Patients cared for by FPs had a lower rate of screening compared to those cared for by internists, despite equal or higher levels of awareness; a difference that remained statistically significant after accounting for socioeconomic status and access to healthcare. Both groups of patients remained below the national goal of 70 percent.

  13. Pioneering Annual Colorectal Cancer Screening and Treatment Targeting Low Income Communities in Malaysia (20102015).

    Science.gov (United States)

    Tze, Christina Ng Van; Fitzgerald, Henry; Qureshi, Akhtar; Tan, Huck Joo; Low, May Lee

    2016-01-01

    The aim of this study was to assess the rate of uptake of a customised annual Colorectal Cancer Awareness, Screening and Treatment Project (CCASTP) using faecal immunohistochemical test (FIT) kits in low income communities in Malaysia. The immediate objectives were (1) to evaluate the level of adherence of CRC screening among lowincome groups, (2) to assess the knowledge and awareness of the screened population and (3) to assess the accuracy of FIT kits. A total of 1,581 FIT kits were distributed between years 2010 to 2015 to healthy asymptomatic participants of the annual CCASTP organized by Empowered the Cancer Advocacy Society of Malaysia. Data for sociodemographic characteristics, critical health and lifestyle information of the registered subjects were collected. Findings for use of the FIT kits were collected when they were returned for stool analyses. Those testingd positive were invited to undergo a colonoscopy examination. A total of 1,436 (90.8%) of the subjects retuned the FITkits, showing high compliance. Among the 129 subjects with positive FIT results, 92 (71.3%) underwent colonoscopy. Six cases (6.5%) of CRC were found. Based on the data collected, the level of awareness of stool examination and knowledge about CRC was poor amongst the participants. Gender, age group, ethnicity and risk factors (i.e. smoking, lack of exercise and low consumption of fresh fruits) were associated with positive FITkit results. In conclusion, CRC screening can be performed in the community with a single FITkit. Although CRC knowledge and awareness is poor in lowincome communities, the average return rate of the FIT kits and rate of colonoscopy examination were 91.2% and 70.3%, respectively.

  14. An experience of qualified preventive screening: shiraz smart screening software.

    Science.gov (United States)

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  15. Interventions to increase recommendation and delivery of screening for breast, cervical, and colorectal cancers by healthcare providers systematic reviews of provider assessment and feedback and provider incentives.

    Science.gov (United States)

    Sabatino, Susan A; Habarta, Nancy; Baron, Roy C; Coates, Ralph J; Rimer, Barbara K; Kerner, Jon; Coughlin, Steven S; Kalra, Geetika P; Chattopadhyay, Sajal

    2008-07-01

    Most major medical organizations recommend routine screening for breast, cervical, and colorectal cancers. Screening can lead to early detection of these cancers, resulting in reduced mortality. Yet not all people who should be screened are screened, either regularly or, in some cases, ever. This report presents results of systematic reviews of effectiveness, applicability, economic efficiency, barriers to implementation, and other harms or benefits of two provider-directed intervention approaches to increase screening for breast, cervical, and colorectal cancers. These approaches, provider assessment and feedback, and provider incentives encourage providers to deliver screening services at appropriate intervals. Evidence in these reviews indicates that provider assessment and feedback interventions can effectively increase screening by mammography, Pap test, and fecal occult blood test. Health plans, healthcare systems, and cancer control coalitions should consider such evidence-based findings when implementing interventions to increase screening use. Evidence was insufficient to determine the effectiveness of provider incentives in increasing use of any of these tests. Specific areas for further research are suggested in this report, including the need for additional research to determine whether provider incentives are effective in increasing use of any of these screening tests, and whether assessment and feedback interventions are effective in increasing other tests for colorectal cancer (i.e., flexible sigmoidoscopy, colonoscopy, or double-contrast barium enema).

  16. Optimizing time management after perforation by colonoscopy results in better outcome for the patients.

    Science.gov (United States)

    Rumstadt, Bernhard; Schilling, Dieter

    2008-01-01

    Perforation during colonoscopy is a rare but severe complication. The aim of this study was to assess the time management and laparoscopic therapy of this complication and to evaluate patient outcomes. A retrospective analysis was done on 15 patients operated for a perforation from colonoscopy between January 2000 and December 2006. Three perforations occurred during diagnostic and 12 perforations during interventional colonoscopy. Two perforations occurred as transmural thermal injury to the colon wall. Peritonitis was found in 4 cases and significantly correlated with the mean time between perforation and operation. Twelve perforations were oversewn laparoscopically and 3 perforations were oversewn by laparotomy. After laparoscopic treatment, hospital stay was significantly shorter than after laparotomy. One patient had a postoperative wound infection, mortality was 0%. Laparoscopic oversewing is a safe and effective method in the treatment of perforation from colonoscopy. Optimizing the time range between perforation and laparoscopic therapy results in a better outcome for the patients.

  17. UK key performance indicators and quality assurance standards for colonoscopy.

    Science.gov (United States)

    Rees, Colin J; Thomas Gibson, Siwan; Rutter, Matt D; Baragwanath, Phil; Pullan, Rupert; Feeney, Mark; Haslam, Neil

    2016-12-01

    Colonoscopy should be delivered by endoscopists performing high quality procedures. The British Society of Gastroenterology, the UK Joint Advisory Group on GI Endoscopy, and the Association of Coloproctology of Great Britain and Ireland have developed quality assurance measures and key performance indicators for the delivery of colonoscopy within the UK. This document sets minimal standards for delivery of procedures along with aspirational targets that all endoscopists should aim for. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Long-Term Impact of the Dutch Colorectal Cancer Screening Program on Cancer Incidence and Mortality-Model-Based Exploration of the Serrated Pathway

    NARCIS (Netherlands)

    Greuter, Marjolein J. E.; Demirel, Erhan; Lew, Jie-Bin; Berkhof, Johannes; Xu, Xiang-Ming; Canfell, Karen; Dekker, Evelien; Meijer, Gerrit A.; Coupé, Veerle M. H.

    2016-01-01

    We aimed to predict the long-term colorectal cancer incidence, mortality, and colonoscopy demand of the recently implemented Dutch colorectal cancer screening program. The Adenoma and Serrated pathway to Colorectal Cancer model was set up to simulate the Dutch screening program consisting of

  19. Providing Hospitalized Patients With an Educational Booklet Increases the Quality of Colonoscopy Bowel Preparation.

    Science.gov (United States)

    Ergen, William F; Pasricha, Trisha; Hubbard, Francie J; Higginbotham, Tina; Givens, Tonya; Slaughter, James C; Obstein, Keith L

    2016-06-01

    Inadequate bowel preparation is a problem frequently encountered by gastroenterologists who perform colonoscopies on hospitalized patients. A method is needed to increase the quality of bowel preparation in inpatients. An educational booklet has been shown to increase the overall quality of bowel preparation for outpatients. We performed a prospective study to evaluate the effects of an educational booklet on the quality of bowel preparation in a group of hospitalized patients. We performed a randomized, single-blind, controlled trial of all inpatients at a tertiary care medical center scheduled for inpatient colonoscopy from October 2013 through March 2014. They were randomly assigned to groups that were (n = 45) or were not (controls, n = 40) given the booklet before bowel preparation the evening before their colonoscopy. All patients received a standard bowel preparation (clear liquid diet the day before the procedure, followed by split-dose GoLYTELY). At the colonoscopy, the Boston Bowel preparation scale (BBPS) was used to assess bowel preparation. The primary outcome measure was adequate bowel preparation (a total BBPS score ≥6 with all segment scores ≥2). Secondary outcomes assessed included total BBPS score, BBPS segment score, and a total BBPS score of 0. There were no differences between the groups in age, race, sex, body mass index, history of colonoscopy, history of polyps, or time of colonoscopy. Twenty-eight patients who received the booklet (62%) and 14 who did not (35%) had an adequate bowel preparation (P = .012). The number needed to treat to attain adequate bowel preparation was 4. After adjusting for age and history of prior colonoscopies, the odds of achieving an adequate bowel preparation and a higher total BBPS score after receipt of the booklet were 3.14 (95% confidence interval, 1.29-7.83) and 2.27 (95% confidence interval, 1.05-4.88), respectively. Three patients in the booklet group and 9 in the no-booklet group had a BBPS score

  20. Appropriateness of endoscopic surveillance recommendations in organised colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Senore, Carlo; Turrin, Anna; Mantellini, Paola; Visioli, Carmen Beatriz; Naldoni, Carlo; Sassoli De' Bianchi, Priscilla; Fedato, Chiara; Anghinoni, Emanuela; Zappa, Marco; Hassan, Cesare

    2016-11-01

    To assess the appropriateness of recommendations for endoscopic surveillance in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). 74 Italian CRC screening programmes provided aggregated data on the recommendations given after FIT-positive colonoscopies in 2011 and 2013. Index colonoscopies were divided into negative/no adenoma and low- risk, intermediate-risk and high-risk adenomas. Postcolonoscopy recommendations included a return to screening (FIT after 2 years or 5 years), an endoscopic surveillance after 6 months or after 1 year, 3 years or 5 years, surgery or other. We assessed the deviation from the postcolonoscopy recommendations of the European Guidelines in 2011 and 2013 and the correlation between overuse of endoscopic surveillance in 2011 and the process indicators associated with the endoscopic workload in 2013. 49 704 postcolonoscopy recommendations were analysed. High-risk, intermediate-risk and low-risk adenomas, and no adenomas were reported in 5.9%, 19.3%, 15.3% and 51.5% of the cases, respectively. Endoscopic surveillance was inappropriately recommended in 67.4% and 7%, respectively, of cases with low-risk and no adenoma. Overall, 37% of all endoscopic surveillance recommendations were inappropriate (6696/17 860). Overuse of endoscopic surveillance was positively correlated with the extension of invitations (correlation coefficient (cc) 0.29; p value 0.03) and with compliance with post-FIT+ colonoscopy (cc 0.25; p value 0.05), while it was negatively correlated with total colonoscopy waiting times longer than 60 days (cc -0.26; p value 0.05). In organised screening programmes, a high rate of inappropriate recommendations for patients with low risk or no adenomas occurs, affecting the demand for endoscopic surveillance by a third. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Difficult colonoscopy: air, carbon dioxide, or water insufflation?

    Science.gov (United States)

    Chaubal, Alisha; Pandey, Vikas; Patel, Ruchir; Poddar, Prateik; Phadke, Aniruddha; Ingle, Meghraj; Sawant, Prabha

    2018-04-01

    This study aimed to compare tolerance to air, carbon dioxide, or water insufflation in patients with anticipated difficult colonoscopy (young, thin, obese individuals, and patients with prior abdominal surgery or irradiation). Patients with body mass index (BMI) less than 18 kg/m 2 or more than 30 kg/m 2 , or who had undergone previous abdominal or pelvic surgeries were randomized to air, carbon dioxide, or water insufflation during colonoscopy. The primary endpoint was cecal intubation with mild pain (less than 5 on visual analogue scale [VAS]), without use of sedation. The primary end point was achieved in 32.7%, 43.8%, and 84.9% of cases with air, carbon dioxide and water insufflation ( P carbon dioxide, and water insufflation ( P carbon dioxide for pain tolerance. This was seen in the subgroups with BMI 30 kg/m 2 .

  2. Effect of psychological preparation on anxiety level before colonoscopy in outpatients referred to Golestan Hospital in Ahvaz

    Institute of Scientific and Technical Information of China (English)

    Hatam Boustani; Sirus Pakseresht; Mohammad-Reza Haghdoust; Saeid Qanbari; Hadis Mehregan-Nasab

    2017-01-01

    BACKGROUND:Gastrointestinal disorders are common complaints for which endoscopy and colonoscopy are the most important diagnostic procedures.Anxiety is an unpleasant,ambiguous feeling of apprehension and fear of unknown origin that occurs during stressful situations or injury.Lack of sufficient information and fear of pain can cause anxiety prior to a colonoscopy,reducing the number of patients willing to undergo the procedure and increasing colonoscopy time.The aim of this study was to evaluate the efficacy of psychological preparation on anxiety before colonoscopy in patients presenting to Golestan Hospital during the years 1994 and 1995.MATERIAL and METHODS:This study was a double-blind clinical trial of patients presenting to the colonoscopy unit in Golestan Hospital in 1994 and 1995.A total of 80 patients were divided into two groups:intervention and control.A primary assessment of anxiety was performed using Spielberger's State-Trait Anxiety Inventory.Before the colonoscopy,the State-Trait Anxiety Inventory was completed by the patients again.The effectiveness of psychological preparation before colonoscopy and its effect on anxiety were evaluated using statistical software SPSS 20.RE SULTS:The mean age of participants was 46.33 ± 12.2 years in the intervention group and 44.8 ± 12.26 years in the control group.In this study,there were 41 males (51.3%) and 39 females (48.7%);15 patients (18.7%) were single and the rest married.In terms of demographic variables,there were no significant differences between the two groups (p > 0.05).The average scores of state and trait anxiety in the intervention group showed a statistically significant difference before and after the intervention (p =0.000).CONCLUSION:Trait and state anxiety levels after psychological preparation showed a statistically significant reduction.This indicates the effectiveness of intervention programs to reduce anxiety before colonoscopy.

  3. Training mid-career internists to perform high-quality colonoscopy: a pilot training programme to meet increasing demands for colonoscopy.

    Science.gov (United States)

    Shah-Ghassemzadeh, Nicole K; Jackson, Christian S; Juma, David; Strong, Richard M

    2017-08-01

    Colorectal cancer (CRC) is the second leading cause of cancer deaths in the USA. Despite a recent rise in CRC screening there remains an increasing demand for colonoscopy, yet a limited supply of gastroenterologists who can meet this need. To determine if a mid-career general internist (GIN) could be trained to perform high-quality colonoscopes via an intensive training programme. A GIN trained 2-3 days/week, 4-5 hours/day, for 7 months with an experienced gastroenterologist. Their independent performance was then compared with that of a gastroenterology attending (GA), with and without a gastroenterology fellow (GF). The primary outcome was to compare caecal intubation rates, adenoma detection rates (ADRs), interval CRC rates and complications between the three groups. 989 patients were initially included in the study, and 818 were included in the final analysis. Caecal intubation rates were 95%, 94% and 93% for the GIN, GA+GF and GA, respectively (p=0.31). The overall polyp detection rates were 68%, 39% and 44% among the GIN, GA+GF and GA, respectively (pdemand for colonoscopists. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Use of high-flow nasal cannula in obese patients receiving colonoscopy under intravenous propofol sedation: A case series

    Directory of Open Access Journals (Sweden)

    Chi Chan Lee

    Full Text Available Intravenous sedation during colonoscopy has become the standard practice in the United States given its higher patient satisfaction and procedural quality. This practice is not free of side effects as a significant proportion of patients undergoing this procedure tend to have respiratory depression and desaturation events. Obesity, as it relates to higher levels of body mass index (BMI has a positive correlation with the incidence of hypoxemia. During colonoscopy High flow nasal cannula (HFNC may potentially improve oxygen performance in patients receiving colonoscopy under intravenous sedation. Here we present 3 cases of patients undergoing adjunctive oxygen therapy with HFNC during colonoscopy with intravenous sedation. We found patients to have lower number of desaturation events and were satisfied with their experience. Keywords: High BMI (body mass index, HFNC (high-flow nasal cannula, Colonoscopy, Intravenous sedation, Obesity

  5. Cost-effectiveness of computed tomography colonography in colorectal cancer screening: a systematic review.

    Science.gov (United States)

    Hanly, Paul; Skally, Mairead; Fenlon, Helen; Sharp, Linda

    2012-10-01

    The European Code Against Cancer recommends individuals aged ≥ 50 should participate in colorectal cancer screening. CT-colonography (CTC) is one of several screening tests available. We systematically reviewed evidence on, and identified key factors influencing, cost-effectiveness of CTC screening. PubMed, Medline, and the Cochrane library were searched for cost-effectiveness or cost-utility analyses of CTC-based screening, published in English, January 1999 to July 2010. Data was abstracted on setting, model type and horizon, screening scenario(s), comparator(s), participants, uptake, CTC performance and cost, effectiveness, ICERs, and whether extra-colonic findings and medical complications were considered. Sixteen studies were identified from the United States (n = 11), Canada (n = 2), and France, Italy, and the United Kingdom (1 each). Markov state-transition (n = 14) or microsimulation (n = 2) models were used. Eleven considered direct medical costs only; five included indirect costs. Fourteen compared CTC with no screening; fourteen compared CTC with colonoscopy-based screening; fewer compared CTC with sigmoidoscopy (8) or fecal tests (4). Outcomes assessed were life-years gained/saved (13), QALYs (2), or both (1). Three considered extra-colonic findings; seven considered complications. CTC appeared cost-effective versus no screening and, in general, flexible sigmoidoscopy and fecal occult blood testing. Results were mixed comparing CTC to colonoscopy. Parameters most influencing cost-effectiveness included: CTC costs, screening uptake, threshold for polyp referral, and extra-colonic findings. Evidence on cost-effectiveness of CTC screening is heterogeneous, due largely to between-study differences in comparators and parameter values. Future studies should: compare CTC with currently favored tests, especially fecal immunochemical tests; consider extra-colonic findings; and conduct comprehensive sensitivity analyses.

  6. Colonoscopy surveillance for dysplasia and colorectal cancer in patients with inflammatory bowel disease

    DEFF Research Database (Denmark)

    Aalykke, Claus; Jensen, Michael Dam; Fallingborg, Jan

    2015-01-01

    The risk of colorectal cancer (CRC) and dysplasia in patients with inflammatory bowel disease (IBD) has been highly debated as risk estimates from different studies vary greatly. The present national Danish guideline on colonoscopy surveillance for dysplasia and colorectal cancer in patients......, in some subgroups of patients the risk is increased. These subgroups of patients, who should be offered colonoscopy surveillance, include patients with ulcerative colitis having extensive disease and a long disease duration (10-13 years); early age at onset (less than 19 years of age) of ulcerative...... colitis; and patients with ulcerative colitis as well as Crohn´s disease with a concomitant diagnosis of primary sclerosing cholangitis. A colonoscopy surveillance program is recommended in these subgroups with intervals ranging from every 3-6 months to every 5 years, using chromoendoscopy with targeted...

  7. Prospective comparison of air-contrast barium enema and colonoscopy in patients with fecal occult blood: a pilot study.

    Science.gov (United States)

    Rockey, Don C; Koch, Johannes; Yee, Judy; McQuaid, Kenneth R; Halvorsen, Robert A

    2004-12-01

    The utility of air-contrast barium enema and colonoscopy for evaluation of the colon has been debated. Air-contrast barium enema is less expensive and invasive than colonoscopy, but it also is less sensitive and specific. Further, although air-contrast barium enema may be less painful than colonoscopy, it often is poorly tolerated by patients. Thus, this study compared the sensitivity and the specificity of air-contrast barium enema and colonoscopy for detection of colonic lesions in patients with fecal occult blood. Over a 30-month period, patients with fecal occult blood were recruited. Patients underwent standard air-contrast barium enema, followed by colonoscopy 7 to 14 days later. Colonoscopists were blinded to the results of air-contrast barium enema until the colonoscopy was completed, after which the results were disclosed. If the findings were discrepant, colonoscopy was repeated. A total of 100 patients were evaluated. Nine air-contrast barium enemas were reported to be inadequate, and the cecum was not intubated at colonoscopy in two patients. In the remaining patients, 5 cancers were identified (1 each cecum, transverse colon, descending colon, sigmoid colon, and rectum) by both studies. Sixty-six polypoid lesions were identified in 30 patients. Diverticula were identified in 42 patients by air-contrast barium enema and in 18 patients by colonoscopy. Air-contrast barium enema detected 3 of 36 polypoid lesions 5 mm or less in diameter, 5 of 15 adenomas 6 to 9 mm in size, and 4 of 15 adenomas 10 mm or greater in diameter (sensitivity 8%, 33%, and 27%, respectively). After excluding patients with diverticula, air-contrast barium enema detected 3 of 7 adenomas 10 mm or greater in size. Overall, 12 polypoid lesions or filling defects were identified by air-contrast barium enema that could not be verified by colonoscopy. The specificity of air-contrast barium enema for lesions 1.0 cm or greater in size was 100%; for those 6 mm or greater, it was 97%. Air

  8. An economic evaluation of colorectal cancer screening in primary care practice.

    Science.gov (United States)

    Meenan, Richard T; Anderson, Melissa L; Chubak, Jessica; Vernon, Sally W; Fuller, Sharon; Wang, Ching-Yun; Green, Beverly B

    2015-06-01

    Recent colorectal cancer screening studies focus on optimizing adherence. This study evaluated the cost effectiveness of interventions using electronic health records (EHRs); automated mailings; and stepped support increases to improve 2-year colorectal cancer screening adherence. Analyses were based on a parallel-design, randomized trial in which three stepped interventions (EHR-linked mailings ["automated"]; automated plus telephone assistance ["assisted"]; or automated and assisted plus nurse navigation to testing completion or refusal [navigated"]) were compared to usual care. Data were from August 2008 to November 2011, with analyses performed during 2012-2013. Implementation resources were micro-costed; research and registry development costs were excluded. Incremental cost-effectiveness ratios (ICERs) were based on number of participants current for screening per guidelines over 2 years. Bootstrapping examined robustness of results. Intervention delivery cost per participant current for screening ranged from $21 (automated) to $27 (navigated). Inclusion of induced testing costs (e.g., screening colonoscopy) lowered expenditures for automated (ICER=-$159) and assisted (ICER=-$36) relative to usual care over 2 years. Savings arose from increased fecal occult blood testing, substituting for more expensive colonoscopies in usual care. Results were broadly consistent across demographic subgroups. More intensive interventions were consistently likely to be cost effective relative to less intensive interventions, with willingness to pay values of $600-$1,200 for an additional person current for screening yielding ≥80% probability of cost effectiveness. Two-year cost effectiveness of a stepped approach to colorectal cancer screening promotion based on EHR data is indicated, but longer-term cost effectiveness requires further study. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  9. Simulation-based training for colonoscopy

    DEFF Research Database (Denmark)

    Preisler, Louise; Svendsen, Morten Bo Søndergaard; Nerup, Nikolaj

    2015-01-01

    in colonoscopy before practicing on patients. Twenty-five physicians (10 consultants with endoscopic experience and 15 fellows with very little endoscopic experience) were tested on 2 different simulator models: a virtual-reality simulator and a physical model. Tests were repeated twice on each simulator model...... on both the models (P virtual-reality and the physical model, respectively. The established pass/fail standards failed one of the consultants (virtual-reality simulator) and allowed one fellow to pass (physical model). The 2 tested...

  10. Readability, suitability, and health content assessment of web-based patient education materials on colorectal cancer screening.

    Science.gov (United States)

    Tian, Chenlu; Champlin, Sara; Mackert, Michael; Lazard, Allison; Agrawal, Deepak

    2014-08-01

    Colorectal cancer (CRC) screening rates in the Unites States are still below target level. Web-based patient education materials are used by patients and providers to provide supplemental information on CRC screening. Low literacy levels and patient perceptions are significant barriers to screening. There are little data on the quality of these online materials from a health literacy standpoint or whether they address patients' perceptions. To evaluate the readability, suitability, and health content of web-based patient education materials on colon cancer screening. Descriptive study. Web-based patient materials. Twelve reputable and popular online patient education materials were evaluated. Readability was measured by using the Flesch-Kincaid Reading Grade Level, and suitability was determined by the Suitability Assessment of Materials, a scale that considers characteristics such as content, graphics, layout/typography, and learning stimulation. Health content was evaluated within the framework of the Health Belief Model, a behavioral model that relates patients' perceptions of susceptibility to disease, severity, and benefits and barriers to their medical decisions. Each material was scored independently by 3 reviewers. Flesch-Kincaid Reading Grade Level score, Suitability Assessment of Materials score, health content score. Readability for 10 of 12 materials surpassed the maximum recommended sixth-grade reading level. Five were 10th grade level and above. Only 1 of 12 materials received a superior suitability score; 3 materials received inadequate scores. Health content analysis revealed that only 50% of the resources discussed CRC risk in the general population and <25% specifically addressed patients at high risk, such as African Americans, smokers, patients with diabetes, and obese patients. For perceived barriers to screening, only 8.3% of resources discussed embarrassment, 25% discussed pain with colonoscopy, 25% addressed cost of colonoscopy, and none

  11. An analysis of the duplicate testing strategy of an Irish immunochemical FOBT colorectal cancer screening programme.

    LENUS (Irish Health Repository)

    Kelley, Leanne

    2013-06-10

    AIM: This study examined the relevance of using a two sample quantitative immunochemical faecal occult blood test (iFOBT or FIT) at a high cut off stringency by the first population-based colorectal cancer (CRC) pilot screening programme in Ireland. METHOD: Approximately ten thousand individuals between the ages of 50-74 years were invited to perform two consecutive FITs. These were analysed in tandem using the OC-Sensor and participants with at least one positive result with a haemoglobin cut off for positivity at 100 ng\\/ml were offered colonoscopy. RESULTS: A total of 5023 (52%) (2177 (43%) male; 2846 (57%) female) individuals with a median age of 64 years participated. At least one positive FIT test was detected from 514 (10%) individuals. From the 419 (82%) patients who proceeded to colonoscopy 17 (4%) had CRC and 132(33%) had an advanced adenoma. The detection rate for these screen relevant lesions was 3% (95% CIs = 2.5% - 3.5%) and the FIT positive + colonoscopy detection rate was 36% (95% CI = 31% - 40%). The numbers needed to colonoscope to find an advanced lesion was 2.8. The two test system detected four (23.5%) additional patients with CRC and 37 (28%) with an advanced adenoma compared with a single test. CONCLUSION: The CRC miss rate estimated for a single test (23.5%) was unacceptably high when the goal was to maximize the discovery of advanced lesions in the initial screening round. We conclude that the two test protocol at a high cut off threshold is suitable to optimize FIT screening in Ireland. This article is protected by copyright. All rights reserved.

  12. Focal Colonic FDG Activity with PET/CT: Guidelines for Recommendation of Colonoscopy

    OpenAIRE

    Liu, Tianye; Behr, Spencer; Khan, Sana; Osterhoff, Robert; Aparici, Carina Mari

    2015-01-01

    Focal 18F-fluorodeoxyglucose (FDG) colonic activity can be incidentally seen in positron emission tomography/computed tomography (PET/CT) scans. Its clinical significance is still unclear. The purpose of this study was to assess the significance of focal FDG activity in PET/CT scans by correlating the imaging findings to colonoscopy results, and come up with some guidelines for recommendation of follow-up colonoscopy. A total of 133 patients who underwent both 18F-FDG PET/CT for different onc...

  13. [Screening of ovarian cancer : not for tomorrow].

    Science.gov (United States)

    Vuilleumier, Aurélie; Labidi-Galy, Intidhar

    2017-05-17

    As the worldwide incidence of cancer continuously rises, one of the measures to reduce mortality is early diagnosis while the disease is still curable. Colonoscopy screening and PAP-smears are worthwhile examples illustrating the impact of early diagnosis on mortality. Ovarian cancer is the first cause of mortality by gynecological cancers in Switzerland (incidence of 600 new cases / year), mostly diagnosed at advanced stages with a poor prognosis. Could surveillance measures improve survival ? Three large-scale randomized control trials failed to show mortality reduction from ovarian cancer with the methods currently available. A better comprehension of pathogenesis can allow the development of new strategies of screening.

  14. Magnetic resonance colonography with a limited bowel preparation and automated carbon dioxide insufflation in comparison to conventional colonoscopy: Patient burden and preferences

    Energy Technology Data Exchange (ETDEWEB)

    Paardt, M.P. van der, E-mail: m.p.vanderpaardt@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Boellaard, T.N., E-mail: t.n.boellaard@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Zijta, F.M., E-mail: fmzijta@yahoo.com [Department of Radiology, Medisch Centrum Haaglanden, Den Haag (Netherlands); Baak, L.C., E-mail: l.c.baak@olvg.nl [Department of Gastroenterology and Hepatology, Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands); Depla, A.C.T.M., E-mail: actm.depla@slz.nl [Department of Gastroenterology and Hepatology, Slotervaartziekenhuis, Amsterdam (Netherlands); Dekker, E., E-mail: e.dekker@amc.uva.nl [Department of Gastroenterology and Hepatology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Nederveen, A.J., E-mail: a.j.nederveen@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Bipat, S., E-mail: s.bipat@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Stoker, J., E-mail: j.stoker@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands)

    2015-01-15

    Highlights: • MR colonography with a limited bowel preparation and automated carbon dioxide insufflation demonstrated less burden compared to colonoscopy. • When discarding the bowel preparation, the examinations were rated equally burdensome. • The majority of patients preferred MR colonography over colonoscopy for their future examination of the bowel. - Abstract: Objectives: To evaluate patient burden and preferences for MR colonography with a limited bowel preparation and automated carbon dioxide insufflation in comparison to conventional colonoscopy. Methods: Symptomatic patients were consecutively recruited to undergo MR colonography with automated carbon dioxide insufflation and a limited bowel preparation followed within four weeks by colonoscopy with a standard bowel cleansing preparation. Four questionnaires regarding burden (on a five-point scale) and preferences (on a seven-point scale) were addressed after MR colonography and colonoscopy and five weeks after colonoscopy. Results: Ninety-nine patients (47 men, 52 women; mean age 62.3, SD 8.7) were included. None of the patients experienced severe or extreme burden from the MR colonography bowel preparation compared to 31.5% of the patients for the colonoscopy bowel preparation. Colonoscopy was rated more burdensome (25.6% severe or extreme burden) compared to MR colonography (5.2% severe or extreme burden) (P < 0.0001). When discarding the bowel preparations, the examinations were rated equally burdensome (P = 0.35). The majority of patients (61.4%) preferred MR colonography compared to colonoscopy (29.5%) immediately after the examinations and five weeks later (57.0% versus 39.5%). Conclusion: MR colonography with a limited bowel preparation and automated carbon dioxide insufflation demonstrated less burden compared to colonoscopy. The majority of patients preferred MR colonography over colonoscopy.

  15. Determination of the SNPP VIIRS SDSM Screen Relative Transmittance From Both Yaw Maneuver and Regular On-Orbit Data

    Science.gov (United States)

    Lei, Ning; Chen, Xuexia; Xiong, Xiaoxiong

    2015-01-01

    The Visible Infrared Imaging Radiometer Suiteaboard the Suomi National Polar-orbiting Partnership (SNPP) satellite performs radiometric calibration of its reflective solar bands primarily through observing a sunlit onboard solar diffuser (SD). The SD bidirectional reflectance distribution function(BRDF) degradation factor is determined by an onboard SD stability monitor (SDSM), which observes the Sun through a pinhole screen and the sunlit SD. The transmittance of the SDSM pinhole screen over a range of solar angles was determined prelaunch and used initially to determine the BRDF degradation factor.The degradation-factor-versus-time curves were found to have a number of very large unphysical undulations likely due to the inaccuracy in the prelaunch determined SDSM screen transmittance.To refine the SDSM screen transmittance, satellite yaw maneuvers were carried out. With the SDSM screen relative transmittance determined from the yaw maneuver data, the computed BRDFdegradation factor curves still have large unphysical ripples, indicating that the projected solar horizontal angular step size in the yaw maneuver data is too large to resolve the transmittance at a fine angular scale. We develop a methodology to use both the yaw maneuver and a small portion of regular on-orbit data to determine the SDSM screen relative transmittance at a fine angular scale. We determine that the error standard deviation of the calculated relative transmittance ranges from 0.00030 (672 nm) to 0.00092 (926 nm). With the newly determined SDSM screen relative transmittance, the computed BRDF degradation factor behaves much more smoothly over time.

  16. Assessing the realism of colonoscopy simulation: the development of an instrument and systematic comparison of 4 simulators.

    Science.gov (United States)

    Hill, Andrew; Horswill, Mark S; Plooy, Annaliese M; Watson, Marcus O; Karamatic, Rozemary; Basit, Tabinda A; Wallis, Guy M; Riek, Stephan; Burgess-Limerick, Robin; Hewett, David G

    2012-03-01

    No useful comparative data exist on the relative realism of commercially available devices for simulating colonoscopy. To develop an instrument for quantifying realism and provide the first wide-ranging empiric comparison. Repeated measures, observational study. Nineteen experienced colonoscopists completed cases on 4 colonoscopy simulators (AccuTouch, GI Mentor II, Koken, and Kyoto Kagaku) and evaluated each device. A medical simulation center in a large tertiary hospital. For each device, colonoscopists completed the newly developed Colonoscopy Simulator Realism Questionnaire (CSRQ), which contains 58 items grouped into 10 subscales measuring the realism of different aspects of the simulation. Subscale scores are weighted and combined into an aggregated score, and there is also a single overall realism item. Overall, current colonoscopy simulators were rated as only moderately realistic compared with real human colonoscopy (mean aggregated score, 56.28/100; range, 48.39-60.45, where 0 = "extremely unrealistic" and 100 = "extremely realistic"). On both overall realism measures, the GI Mentor II was rated significantly less realistic than the AccuTouch, Kyoto Kagaku, and Koken (P realism. There is no clear "first choice" simulator among those assessed. Each has unique strengths and weaknesses, reflected in the differing results observed across 9 subscales. These findings may facilitate the targeted selection of simulators for various aspects of colonoscopy training. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. Knowledge of colorectal cancer screening guidelines and intention to obtain screening among nonadherent Filipino, Hmong, and Korean Americans.

    Science.gov (United States)

    Tsoh, Janice Y; Tong, Elisa K; Sy, Angela U; Stewart, Susan L; Gildengorin, Ginny L; Nguyen, Tung T

    2018-04-01

    Nonadherence to colorectal cancer (CRC) screening among Asian Americans is high but not well understood. This study examined correlates of screening intention among Filipino, Hmong, and Korean Americans who were nonadherent to CRC screening. Using cross-sectional, preintervention survey data from 504 Asian Americans (115 Filipinos, 185 Hmong, and 204 Koreans) aged 50-75 years who were enrolled in a multisite cluster randomized controlled trial of lay health educator intervention, we analyzed correlates of self-reported CRC screening nonadherence, which was defined as not being up-to-date for fecal occult blood test, sigmoidoscopy, or colonoscopy. Only 26.8% of participants indicated intention to obtain screening within 6 months (Hmong: 12.4%; Korean: 30.8%; and Filipino: 42.6%; P Filipinos, which was unexplained by socio-demographics, health care factors, perceived needs for CRC screening, or knowledge of screening guidelines. CRC screening intention among nonadherent Filipino, Hmong, and Korean Americans was low. Targeting knowledge of CRC screening guidelines may be effective strategies for increasing CRC screening intention among nonadherent Asian Americans. Cancer 2018;124:1560-7. © 2018 American Cancer Society. © 2018 American Cancer Society.

  18. The median effective concentration (EC50) of propofol with different doses of fentanyl during colonoscopy in elderly patients.

    Science.gov (United States)

    Li, Shiyang; Yu, Fang; Zhu, Huichen; Yang, Yuting; Yang, Liqun; Lian, Jianfeng

    2016-04-21

    Propofol and fentanyl are the most widely administered anesthesia maintaining drugs during colonoscopy. In this study, we determined the median effective concentration (EC50) of propofol required for colonoscopy in elderly patients, and the purpose of this study was to describe the pharmacodynamic interaction between fentanyl and propofol when used in combination for colonoscopy in elderly patients. Ninety elderly patients scheduled for colonoscopy were allocated into three groups in a randomized, double-blinded manner as below, F0.5 group (0.5 μg.kg(-1) fentanyl), F1.0 group (1.0 μg.kg(-1) fentanyl) and saline control group. Anaesthesia was achieved by target-controlled infusion of propofol (Marsh model, with an initial plasma concentration of 2.0 μg.ml(-1)) and fentanyl. Colonoscopy was started 3 min after the injection of fentanyl. The EC50 of propofol for colonoscopy with different doses of fentanyl was measured by using an up-and-down sequential method with an adjacent concentration gradient at 0.5 μg.ml(-1) to inhibit purposeful movements. Anaesthesia associated adverse events and recovery characters were also recorded. The EC50 of propofol for colonoscopy in elderly patients were 2.75 μg.ml(-1) (95% CI, 2.50-3.02 μg.ml(-1)) in F0.5 group, 2.05 μg.ml(-1) (95% CI, 1.98-2.13 μg.ml(-1)) in F1.0 group and 3.08 μg.ml(-1) (95% CI, 2.78-3.42 μg.ml(-1)) in control group respectively (P fentanyl up to 1.0 μg.kg(-1) reduces the propofol EC50 required for elderly patients undergoing colonoscopy, and there was no significant difference in anaesthesia associated adverse events but prolonged awake and discharge time. Chinese Clinical Trial Registry ChiCTR15006368. Date of registration: May 3, 2015.

  19. Colonoscopic Diagnostic Findings in Patients Undergoing Colonoscopy In Qom Hazrat-e-Masoome Hospital During 2007-2008

    Directory of Open Access Journals (Sweden)

    M.R Ghadir

    2012-05-01

    Full Text Available

    Background and Objectives: In recent years there have been noticeable changes in diagnosis and treatment of colon disorders by colonoscopy and direct vision. Along with its international development, this useful equipment is being used in Iran to treat various disorders. It should be mentioned that there are no exact statistics of these disorders to date. This study was done with aim of evaluating the diagnostic findings in patients undergoing colonoscopy in Qom during 2007-2008.

     

    Methods: This descriptive-cross sectional study was done on 500 patients having referred to colonoscopy ward of Hazrate-e-Masoome Hospital in Qom. After colonoscopy, patient data were entered into a special questionnaire and then pathologic findings were added to it. The data were taken for statistical analysis.

     

    Results: Out of 500 patients undergoing colonoscopy 279 were male (55.8% and 221 female (44.2%. In all groups and both sexes the most common reason for carrying out colonoscopy was abdominal pain (46.6% rectorrhagia (41%. As regards diagnosis, a total of 199 cases (39.8% of all 500 colonoscopies had normal colonoscopy,124 cases (24.8% had hemorrhoid, 64 cases (12.8% had polyp, 55 cases (11% had inflammatory bowel diseases (IBD, 30 cases (6% had tumor, 17 cases(3.2% had diverticulosis and 12 cases (2.4% had solitary rectal ulcer. There was a significant relationship between abdominal pain and tumor, polyp and diverticulosis. (p<0.001 There was also a significant relationship between age and the aforementioned disorders. (p<0.001

     

    Conclusion: Based on the findings of this study, the prevalence of cancer and IBD is higher in men

  20. Multicenter, randomized, controlled trial of virtual-reality simulator training in acquisition of competency in colonoscopy.

    Science.gov (United States)

    Cohen, Jonathan; Cohen, Seth A; Vora, Kinjal C; Xue, Xiaonan; Burdick, J Steven; Bank, Simmy; Bini, Edmund J; Bodenheimer, Henry; Cerulli, Maurice; Gerdes, Hans; Greenwald, David; Gress, Frank; Grosman, Irwin; Hawes, Robert; Mullin, Gerard; Mullen, Gerard; Schnoll-Sussman, Felice; Starpoli, Anthony; Stevens, Peter; Tenner, Scott; Villanueva, Gerald

    2006-09-01

    The GI Mentor is a virtual reality simulator that uses force feedback technology to create a realistic training experience. To define the benefit of training on the GI Mentor on competency acquisition in colonoscopy. Randomized, controlled, blinded, multicenter trial. Academic medical centers with accredited gastroenterology training programs. First-year GI fellows. Subjects were randomized to receive 10 hours of unsupervised training on the GI Mentor or no simulator experience during the first 8 weeks of fellowship. After this period, both groups began performing real colonoscopies. The first 200 colonoscopies performed by each fellow were graded by proctors to measure technical and cognitive success, and patient comfort level during the procedure. A mixed-effects model comparison between the 2 groups of objective and subjective competency scores and patient discomfort in the performance of real colonoscopies over time. Forty-five fellows were randomized from 16 hospitals over 2 years. Fellows in the simulator group had significantly higher objective competency rates during the first 100 cases. A mixed-effects model demonstrated a higher objective competence overall in the simulator group (P < .0001), with the difference between groups being significantly greater during the first 80 cases performed. The median number of cases needed to reach 90% competency was 160 in both groups. The patient comfort level was similar. Fellows who underwent GI Mentor training performed significantly better during the early phase of real colonoscopy training.

  1. Time of day variation in polyp detection rate for colonoscopies performed on a 3-hour shift schedule.

    LENUS (Irish Health Repository)

    Munson, Gregory W

    2011-03-01

    Recent research suggests that the colonoscopy polyp detection rate (PDR) varies by time of day, possibly because of endoscopist fatigue. Mayo Clinic Rochester (MCR) schedules colonoscopies on 3-hour shifts, which should minimize fatigue.

  2. CT colonography with limited bowel preparation: prospective assessment of patient experience and preference in comparison to optical colonoscopy with cathartic bowel preparation

    International Nuclear Information System (INIS)

    Jensch, Sebastiaan; Bipat, Shandra; Vries, Ayso H. de; Heutinck, Anneke; Stoker, Jaap; Peringa, Jan; Montauban van Swijndregt, Alexander D.; Dekker, Evelien; Baak, Lubbertus C.

    2010-01-01

    The purpose of this study was to prospectively compare participant experience and preference of limited preparation computed tomography colonography (CTC) with full-preparation colonoscopy in a consecutive series of patients at increased risk of colorectal cancer. CTC preparation comprised 180 ml diatrizoate meglumine, 80 ml barium and 30 mg bisacodyl. For the colonoscopy preparation 4 l of polyethylene glycol solution was used. Participants' experience and preference were compared using the Wilcoxon signed rank test and the chi-squared test, respectively. Associations between preference and experience parameters for the 173 participants were determined by logistic regression. Diarrhoea occurred in 94% of participants during CTC preparation. This side effect was perceived as severely or extremely burdensome by 29%. Nonetheless, the total burden was significantly lower for the CTC preparation than for colonoscopy (9% rated the CTC preparation as severely or extremely burdensome compared with 59% for colonoscopy; p<0.001). Participants experienced significantly more pain, discomfort and total burden with the colonoscopy procedure than with CTC (p<0.001). After 5 weeks, 69% preferred CTC, 8% were indifferent and 23% preferred colonoscopy (p<0.001). A burdensome colonoscopy preparation and pain at colonoscopy were associated with CTC preference (p<0.04). In conclusion, participants' experience and preference were rated in favour of CTC with limited bowel preparation compared with full-preparation colonoscopy. (orig.)

  3. Natural history of diminutive colorectal polyps: long-term prospective observation by colonoscopy.

    Science.gov (United States)

    Mizuno, Ken-Ichi; Suzuki, Yutaka; Takeuchi, Manabu; Kobayashi, Masaaki; Aoyagi, Yutaka

    2014-04-01

    Endoscopic removal of colorectal adenomatous polyps effectively prevents cancer. However, the treatment strategy for diminutive polyps (diameter ≤ 5 mm) remains controversial. Understanding the natural history of diminutive polyps is a prerequisite to their effective management. We prospectively examined the natural history of diminutive polyps by long-term surveillance colonoscopy. A total of 207 polyps detected in 112 patients from December 1991 through March 2002 were studied. To avoid potential effects on size and morphological characteristics, all polyps were selected randomly and were followed without biopsy. Polyp size was estimated by comparing the lesion with the diameter of a biopsy forceps. Mean follow up was 7.8 years (SD, 4.8; range, 1.0-18.6; median, 7.5; interquartile range 3.4-11.2). Twenty-four polyps were resected endoscopically, and the histopathological diagnosis was mucosal high-grade neoplasia (Category 4) for one polyp, and mucosal low-grade neoplasia (Category 3) for 23 polyps. Mean linear size of the polyps was 3.2 mm (SD, 1.0; range, 1.3-5.0) at initial colonoscopy and 3.8 mm (SD 1.6; range 1.3-10.0) at final colonoscopy (Ppit pattern was associated with a lower growth rate than a type IIIL1 pattern. We clarified the natural history of diminutive polyps by long-term follow-up colonoscopy. The benign course of diminutive polyps should be considered in the design of treatment strategies. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  4. Barriers and facilitators associated with colonoscopy completion in individuals with multiple chronic conditions: a qualitative study

    Directory of Open Access Journals (Sweden)

    Sultan S

    2017-05-01

    Full Text Available Shahnaz Sultan,1–4 Melissa R Partin,1,2 Phalgoon Shah,5 Jennifer LeLaurin,4 Ivette Magaly Freytes,4 Chandylen L Nightingale,6 Susan F Fesperman,4 Barbara A Curbow,7 Rebecca J Beyth3,4,8 1Center for Chronic Disease Outcomes Research, Minneapolis Veterans Affairs Health Care System, 2Department of Medicine, University of Minnesota, Minneapolis, MN, 3Department of Medicine, University of Florida College of Medicine, Gainesville, FL, 4Center of Innovation on Disability and Rehabilitation Research, North Florida/South Georgia Veterans Health System, Gainesville, FL, 5Department of Medicine, Tripler Army Medical Center, Honolulu, HI, 6Department of Social Sciences and Health Policy, Wake Forest School of Medicine, Winston-Salem NC, 7Department of Community and Behavioral Health, University of Maryland, College Park, MD, 8Geriatric Research, Education and Clinical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL, USA Background: A recommendation to undergo a colonoscopy, an invasive procedure that requires commitment and motivation, planning (scheduling and finding a driver and preparation (diet restriction and laxative consumption, may be uniquely challenging for individuals with multiple chronic conditions (MCCs. This qualitative study aimed to describe the barriers and facilitators to colonoscopy experienced by such patients.Materials and methods: Semistructured focus groups were conducted with male Veterans who were scheduled for outpatient colonoscopy and either failed to complete the procedure or completed the examination. Focus group recordings were transcribed and analyzed by an inductive grounded approach using constant comparative analysis.Results: Forty-four individuals aged 51–83 years participated in this study (23 adherent and 21 nonadherent. Participants had an average of 7.4 chronic conditions (range 2–14. The five most common chronic conditions were hypertension (75%, hyperlipidemia (75

  5. Measuring cognitive load during procedural skills training with colonoscopy as an exemplar.

    Science.gov (United States)

    Sewell, Justin L; Boscardin, Christy K; Young, John Q; Ten Cate, Olle; O'Sullivan, Patricia S

    2016-06-01

    Few studies have investigated cognitive factors affecting learning of procedural skills in medical education. Cognitive load theory, which focuses on working memory, is highly relevant, but methods for measuring cognitive load during procedural training are not well understood. Using colonoscopy as an exemplar, we used cognitive load theory to develop a self-report instrument to measure three types of cognitive load (intrinsic, extraneous and germane load) and to provide evidence for instrument validity. We developed the instrument (the Cognitive Load Inventory for Colonoscopy [CLIC]) using a multi-step process. It included 19 items measuring three types of cognitive load, three global rating items and demographics. We then conducted a cross-sectional survey that was administered electronically to 1061 gastroenterology trainees in the USA. Participants completed the CLIC following a colonoscopy. The two study phases (exploratory and confirmatory) each lasted for 10 weeks during the 2014-2015 academic year. Exploratory factor analysis determined the most parsimonious factor structure; confirmatory factor analysis assessed model fit. Composite measures of intrinsic, extraneous and germane load were compared across years of training and with global rating items. A total of 477 (45.0%) invitees participated (116 in the exploratory study and 361 in the confirmatory study) in 154 (95.1%) training programmes. Demographics were similar to national data from the USA. The most parsimonious factor structure included three factors reflecting the three types of cognitive load. Confirmatory factor analysis verified that a three-factor model was the best fit. Intrinsic, extraneous and germane load items had high internal consistency (Cronbach's alpha 0.90, 0.87 and 0.96, respectively) and correlated as expected with year in training and global assessment of cognitive load. The CLIC measures three types of cognitive load during colonoscopy training. Evidence of validity is

  6. Midazolam versus diazepam for combined esophogastroduodenoscopy and colonoscopy.

    Science.gov (United States)

    Brouillette, D E; Leventhal, R; Kumar, S; Berman, D; Kajani, M; Yoo, Y K; Carra, J; Tarter, R; Van Thiel, D H

    1989-08-01

    This study compares the effects of two different benzodiazepines used for conscious sedation during combined upper gastrointestinal endoscopy (EGD) and colonoscopy. Subjects were assessed for their degree of analgesia and amnesia for the procedure, prior experience with endoscopy, and willingness to undergo another similar procedure should such be necessary. The patients were randomized single blind to receive either midazolam or diazepam for their preprocedure sedation. The amount of preprocedure sedation utilized was determined by titration of the dose to achieve slurring of speech. Prior to receiving either agent, the subjects were shown a standard card containing pictures of 10 common objects, were asked to name and remember them, and were told they would be "quizzed" (at 30 min and 24 hr) after being sedated for their recollection as to the objects pictured on the card. Each subject filled out a questionnaire addressing their perceived discomfort during the endoscopic procedure and their memory of the procedure 24 hr after the procedure. Sixty-three percent of the midazolam-sedated subjects reported total amnesia for their colonoscopy vs 20% of diazepam-sedated patients (P less than 0.001). Fifty-three percent of midazolam-sedated patients reported total amnesia of their upper gastrointestinal endoscopy vs only 23% of diazepam-sedated subjects (P less than 0.05). The midazolam-sedated subjects reported experiencing less pain with both upper gastrointestinal endoscopy (P less than 0.05) and colonoscopy (P less than 0.001) than did the diazepam-sedated group. Most importantly, the midazolam group was more willing to undergo another similar endoscopic procedure should they be asked to do so by their physician (P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Optimal preparation-to-colonoscopy interval in split-dose PEG bowel preparation determines satisfactory bowel preparation quality: an observational prospective study.

    Science.gov (United States)

    Seo, Eun Hee; Kim, Tae Oh; Park, Min Jae; Joo, Hee Rin; Heo, Nae Yun; Park, Jongha; Park, Seung Ha; Yang, Sung Yeon; Moon, Young Soo

    2012-03-01

    Several factors influence bowel preparation quality. Recent studies have indicated that the time interval between bowel preparation and the start of colonoscopy is also important in determining bowel preparation quality. To evaluate the influence of the preparation-to-colonoscopy (PC) interval (the interval of time between the last polyethylene glycol dose ingestion and the start of the colonoscopy) on bowel preparation quality in the split-dose method for colonoscopy. Prospective observational study. University medical center. A total of 366 consecutive outpatients undergoing colonoscopy. Split-dose bowel preparation and colonoscopy. The quality of bowel preparation was assessed by using the Ottawa Bowel Preparation Scale according to the PC interval, and other factors that might influence bowel preparation quality were analyzed. Colonoscopies with a PC interval of 3 to 5 hours had the best bowel preparation quality score in the whole, right, mid, and rectosigmoid colon according to the Ottawa Bowel Preparation Scale. In multivariate analysis, the PC interval (odds ratio [OR] 1.85; 95% CI, 1.18-2.86), the amount of PEG ingested (OR 4.34; 95% CI, 1.08-16.66), and compliance with diet instructions (OR 2.22l 95% CI, 1.33-3.70) were significant contributors to satisfactory bowel preparation. Nonrandomized controlled, single-center trial. The optimal time interval between the last dose of the agent and the start of colonoscopy is one of the important factors to determine satisfactory bowel preparation quality in split-dose polyethylene glycol bowel preparation. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  8. Cecal intubation time between cap-assisted water exchange and water exchange colonoscopy: a randomized-controlled trial.

    Science.gov (United States)

    Tseng, Chih-Wei; Koo, Malcolm; Hsieh, Yu-Hsi

    2017-11-01

    The water exchange (WE) method can decrease the discomfort of the patients undergoing colonoscopy. It also provides salvage cleansing and improves adenoma detection, but a longer intubation time is required. Cap-assisted colonoscopy leads to a significant reduction in cecal intubation time compared with traditional colonoscopy with air insufflation. The aim of this study was to investigate whether combined cap-assisted colonoscopy and water exchange (CWE) could decrease the cecal intubation time compared with WE. A total of 120 patients undergoing fully sedated colonoscopy at a regional hospital in southern Taiwan were randomized to colonoscopy with either CWE (n=59) or WE (n=61). The primary endpoint was cecal intubation time. The mean cecal intubation time was significantly shorter in CWE (12.0 min) compared with WE (14.8 min) (P=0.004). The volume of infused water during insertion was lower in CWE (840 ml) compared with WE (1044 ml) (P=0.003). The adenoma detection rate was 50.8 and 47.5% for CWE and WE, respectively (P=0.472). The Boston Bowel Preparation Scale scores were comparable in the two groups. Results from the multiple linear regression analysis indicated that WE with a cap, a higher degree of endoscopist's experience, a higher Boston Bowel Preparation Scale score, and a lower volume of water infused during insertion, without abdominal compression, without change of position, and without chronic laxative use, were significantly associated with a shorter cecal intubation time. In comparison with WE, CWE could shorten the cecal intubation time and required lower volume of water infusion during insertion without compromising the cleansing effect of WE.

  9. Experience with a two-tier reflex gFOBT/FIT strategy in a national bowel screening programme.

    Science.gov (United States)

    Fraser, Callum G; Digby, Jayne; McDonald, Paula J; Strachan, Judith A; Carey, Francis A; Steele, Robert J C

    2012-03-01

    To evaluate a two-tier reflex guaiac-based faecal occult blood test (gFOBT)/faecal immunochemical test (FIT) algorithm in screening for colorectal cancer. Fourth screening round in NHS Tayside (Scotland). gFOBT were sent to 50-74-year-olds. Participants with five or six windows positive were offered colonoscopy. Participants with one to four windows positive were sent a FIT and, if positive, were offered colonoscopy. Participants providing an untestable gFOBT were sent a FIT and, if positive, were offered colonoscopy. Outcomes following positive results, cancer stages and key performance indicators were assessed. Of 131,885 invited, 73,315 (55.6%) responded. There were 66,957 (91.3%) negative, 241 (0.3%) strong positive, 5230 (7.1%) weak positive and 887 (1.2%) untestable results. The 241 participants who had five or six windows positive had more cancers than those positive by other routes: only 3 of the 30 cancers (9.7%) were Dukes' A. Among the 983 positive results from the weak positive gFOBT then positive FIT route, there were fewer cancers and more normal colonoscopies, but more adenomas than in the group with a strong positive gFOBT. In those with an untestable gFOBT, 77 had a positive FIT result, with fewer true and more false positive results than in the other groups. Fewer males had cancer and stages were earlier than in females, but more had adenoma. The detection rate for cancer was 0.18% and the PPV for cancer and all adenomas was 41.3%. The algorithm and FIT following a weak positive gFOBT have advantages. FIT following an untestable gFOBT warrants review.

  10. How does genetic risk information for Lynch syndrome translate to risk management behaviours?

    Science.gov (United States)

    Steel, Emma; Robbins, Andrew; Jenkins, Mark; Flander, Louisa; Gaff, Clara; Keogh, Louise

    2017-01-01

    There is limited research on why some individuals who have undergone predictive genetic testing for Lynch syndrome do not adhere to screening recommendations. This study aimed to explore qualitatively how Lynch syndrome non-carriers and carriers translate genetic risk information and advice to decisions about risk managment behaviours in the Australian healthcare system. Participants of the Australasian Colorectal Cancer Family Registry who had undergone predictive genetic testing for Lynch syndrome were interviewed on their risk management behaviours. Transcripts were analysed thematically using a comparative coding analysis. Thirty-three people were interviewed. Of the non-carriers ( n  = 16), 2 reported having apparently unnecessary colonoscopies, and 6 were unsure about what population-based colorectal cancer screening entails. Of the carriers ( n  = 17), 2 reported they had not had regular colonoscopies, and spoke about their discomfort with the screening process and a lack of faith in the procedure's ability to reduce their risk of developing colorectal cancer. Of the female carriers ( n  = 9), 2 could not recall being informed about the associated risk of gynaecological cancers. Non-carriers and female carriers of Lynch syndrome could benefit from further clarity and advice about appropriate risk management options. For those carriers who did not adhere to colonoscopy screening, a lack of faith in both genetic test results and screening were evident. It is essential that consistent advice is offered to both carriers and non-carriers of Lynch syndrome.

  11. Findings in young adults at colonoscopy from a hospital service database audit.

    Science.gov (United States)

    Wong, Stephanie; Lidums, Ilmars; Rosty, Christophe; Ruszkiewicz, Andrew; Parry, Susan; Win, Aung Ko; Tomita, Yoko; Vatandoust, Sina; Townsend, Amanda; Patel, Dainik; Hardingham, Jennifer E; Roder, David; Smith, Eric; Drew, Paul; Marker, Julie; Uylaki, Wendy; Hewett, Peter; Worthley, Daniel L; Symonds, Erin; Young, Graeme P; Price, Timothy J; Young, Joanne P

    2017-04-19

    Colorectal cancer (CRC) diagnosed at young adults. The aim of this work was to document the prevalence and histological subtype of lesions seen in patients aged <50 years, and any associated clinical features. An audit of the colonoscopy database at The Queen Elizabeth Hospital in Adelaide, South Australia over a 12-month period was undertaken. Findings were recorded from both colonoscopy reports and corresponding histological examination of excised lesions. Data were extracted from colonoscopies in 2064 patients. Those aged <50 comprised 485 (24%) of the total. CRC precursor lesions (including sessile serrated adenoma/polyps (SSA/P), traditional serrated adenomas, tubular adenomas ≥10 mm or with high-grade dysplasia, and conventional adenomas with villous histology) were seen in 4.3% of patients aged <50 and 12.9% of patients aged ≥50 (P <0.001). Among colonoscopies yielding CRC precursor lesions in patients under 50 years, SSA/P occurred in 52% of procedures (11/21), compared with 27% (55/204) of procedures in patients aged 50 and older (P = 0.02). SSA/P were proximally located in (10/11) 90% of patients aged under 50, and 80% (43/54) of those aged 50 and older (P = 0.46). SSA/P were the most frequently observed CRC precursor lesions in patients aged <50. Most CRCs in this age group are known to arise in the distal colon and rectum suggesting that lesions other than SSA/P may serve as the precursor for the majority of early-onset CRC.

  12. Results of National Colorectal Cancer Screening Program in Croatia (2007-2011)

    Science.gov (United States)

    Katičić, Miroslava; Antoljak, Nataša; Kujundžić, Milan; Stamenić, Valerija; Skoko Poljak, Dunja; Kramarić, Danica; Štimac, Davor; Strnad Pešikan, Marija; Šamija, Mirko; Ebling, Zdravko

    2012-01-01

    AIM: To study the epidemiologic indicators of uptake and characteristic colonoscopic findings in the Croatian National Colorectal Cancer Screening Program. METHODS: Colorectal cancer (CRC) was the second leading cause of cancer mortality in men (n = 1063, 49.77/100  000), as well as women (n = 803, 34.89/100  000) in Croatia in 2009. The Croatian National CRC Screening Program was established by the Ministry of Health and Social Welfare, and its implementation started in September, 2007. The coordinators were recruited in each county institute of public health with an obligation to provide fecal occult blood testing (FOBT) to the participants, followed by colonoscopy in all positive cases. The FOBT was performed by hypersensitive guaiac-based Hemognost card test (Biognost, Zagreb). The test and short questionnaire were delivered to the home addresses of all citizens aged 50-74 years consecutively during a 3-year period. Each participant was required to complete the questionnaire and send it together with the stool specimen on three test cards back to the institute for further analysis. About 4% FOBT positive cases are expected in normal risk populations. A descriptive analysis was performed. RESULTS: A total of 1  056  694 individuals (born between 1933-1945 and 1952-1957) were invited to screening by the end of September 2011. In total, 210  239 (19.9%) persons returned the envelope with a completed questionnaire, and 181 102 of them returned it with a correctly placed stool specimen on FOBT cards. Until now, 12  477 (6.9%), FOBT-positive patients have been found, which is at the upper limit of the expected values in European Guidelines for Quality Assurance in CRC Screening and Diagnosis [European Union (EU) Guidelines]. Colonoscopy was performed in 8541 cases (uptake 66%). Screening has identified CRC in 472 patients (5.5% of colonoscopied, 3.8% of FOBT-positive, and 0.26% of all screened individuals). This is also in the expected range

  13. Results of National Colorectal Cancer Screening Program in Croatia (2007-2011).

    Science.gov (United States)

    Katičić, Miroslava; Antoljak, Nataša; Kujundžić, Milan; Stamenić, Valerija; Skoko Poljak, Dunja; Kramarić, Danica; Stimac, Davor; Strnad Pešikan, Marija; Samija, Mirko; Ebling, Zdravko

    2012-08-28

    To study the epidemiologic indicators of uptake and characteristic colonoscopic findings in the Croatian National Colorectal Cancer Screening Program. Colorectal cancer (CRC) was the second leading cause of cancer mortality in men (n = 1063, 49.77/100,000), as well as women (n = 803, 34.89/100,000) in Croatia in 2009. The Croatian National CRC Screening Program was established by the Ministry of Health and Social Welfare, and its implementation started in September, 2007. The coordinators were recruited in each county institute of public health with an obligation to provide fecal occult blood testing (FOBT) to the participants, followed by colonoscopy in all positive cases. The FOBT was performed by hypersensitive guaiac-based Hemognost card test (Biognost, Zagreb). The test and short questionnaire were delivered to the home addresses of all citizens aged 50-74 years consecutively during a 3-year period. Each participant was required to complete the questionnaire and send it together with the stool specimen on three test cards back to the institute for further analysis. About 4% FOBT positive cases are expected in normal risk populations. A descriptive analysis was performed. A total of 1,056,694 individuals (born between 1933-1945 and 1952-1957) were invited to screening by the end of September 2011. In total, 210,239 (19.9%) persons returned the envelope with a completed questionnaire, and 181,102 of them returned it with a correctly placed stool specimen on FOBT cards. Until now, 12,477 (6.9%), FOBT-positive patients have been found, which is at the upper limit of the expected values in European Guidelines for Quality Assurance in CRC Screening and Diagnosis [European Union (EU) Guidelines]. Colonoscopy was performed in 8541 cases (uptake 66%). Screening has identified CRC in 472 patients (5.5% of colonoscopied, 3.8% of FOBT-positive, and 0.26% of all screened individuals). This is also in the expected range according to EU Guidelines. Polyps were found and

  14. Evidence-based recommendations for bowel cleansing before colonoscopy in children: a report from a national working group.

    Science.gov (United States)

    Turner, D; Levine, A; Weiss, B; Hirsh, A; Shamir, R; Shaoul, R; Berkowitz, D; Bujanover, Y; Cohen, S; Eshach-Adiv, O; Jamal, Gera; Kori, M; Lerner, A; On, A; Rachman, L; Rosenbach, Y; Shamaly, H; Shteyer, E; Silbermintz, A; Yerushalmi, B

    2010-12-01

    There are no current recommendations for bowel cleansing before colonoscopy in children. The Israeli Society of Pediatric Gastroenterology and Nutrition (ISPGAN) established an iterative working group to formulate evidence-based guidelines for bowel cleansing in children prior to colonoscopy. Data were collected by systematic review of the literature and via a national-based survey of all endoscopy units in Israel. Based on the strength of evidence, the Committee reached consensus on six recommended protocols in children. Guidelines were finalized after an open audit of ISPGAN members. Data on 900 colonoscopies per year were accrued, which represents all annual pediatric colonoscopies performed in Israel. Based on the literature review, the national survey, and the open audit, several age-stratified pediatric cleansing protocols were proposed: two PEG-ELS protocols (polyethylene-glycol with electrolyte solution); Picolax-based protocol (sodium picosulphate with magnesium citrate); sodium phosphate protocol (only in children over the age of 12 years who are at low risk for renal damage); stimulant laxative-based protocol (e. g. bisacodyl); and a PEG 3350-based protocol. A population-based analysis estimated that the acute toxicity rate of oral sodium phosphate is at most 3/7320 colonoscopies (0.041 %). Recommendations on diet and enema use are provided in relation to each proposed protocol. There is no ideal bowel cleansing regimen and, thus, various protocols are in use. We propose several evidence-based protocols to optimize bowel cleansing in children prior to colonoscopy and minimize adverse events. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Information Engineering and Workflow Design in a Clinical Decision Support System for Colorectal Cancer Screening in Iran.

    Science.gov (United States)

    Maserat, Elham; Seied Farajollah, Seiede Sedigheh; Safdari, Reza; Ghazisaeedi, Marjan; Aghdaei, Hamid Asadzadeh; Zali, Mohammad Reza

    2015-01-01

    Colorectal cancer is a major cause of morbidity and mortality throughout the world. Colorectal cancer screening is an optimal way for reducing of morbidity and mortality and a clinical decision support system (CDSS) plays an important role in predicting success of screening processes. DSS is a computer-based information system that improves the delivery of preventive care services. The aim of this article was to detail engineering of information requirements and work flow design of CDSS for a colorectal cancer screening program. In the first stage a screening minimum data set was determined. Developed and developing countries were analyzed for identifying this data set. Then information deficiencies and gaps were determined by check list. The second stage was a qualitative survey with a semi-structured interview as the study tool. A total of 15 users and stakeholders' perspectives about workflow of CDSS were studied. Finally workflow of DSS of control program was designed by standard clinical practice guidelines and perspectives. Screening minimum data set of national colorectal cancer screening program was defined in five sections, including colonoscopy data set, surgery, pathology, genetics and pedigree data set. Deficiencies and information gaps were analyzed. Then we designed a work process standard of screening. Finally workflow of DSS and entry stage were determined. A CDSS facilitates complex decision making for screening and has key roles in designing optimal interactions between colonoscopy, pathology and laboratory departments. Also workflow analysis is useful to identify data reconciliation strategies to address documentation gaps. Following recommendations of CDSS should improve quality of colorectal cancer screening.

  16. A retrospective study on the use of post-operative colonoscopy following potentially curative surgery for colorectal cancer in a Canadian province

    Directory of Open Access Journals (Sweden)

    Bryant Heather E

    2004-04-01

    Full Text Available Abstract Background Surveillance colonoscopy is commonly recommended following potentially curative surgery for colorectal cancer. We determined factors associated with patients undergoing a least one colonoscopy within five years of surgery. Methods In this historical cohort study, data on 3918 patients age 30 years or older residing in Alberta, Canada, who had undergone a potentially curative surgical resection for local or regional stage colorectal cancer between 1983 and 1995 were obtained from the provincial cancer registry, ministry of health and cancer clinic charts. Kaplan-Meier estimates of the probability of undergoing a post-operative colonoscopy were calculated for patient, tumor and treatment-related variables of interest. Results A colonoscopy was performed within five years of surgery in 1979 patients. The probability of undergoing a colonoscopy for those diagnosed in the 1990s was greater than for those diagnosed earlier (0.65 vs 0.55, P Conclusions The majority of patients undergo colonoscopy following colorectal cancer surgery. However, there are important variations in surveillance practices across different patient and treatment characteristics.

  17. POPULATION BASED COLORECTAL CANCER SCREENING: COMPARISON OF TWO FAECAL OCCULT BLOOD TESTS

    Directory of Open Access Journals (Sweden)

    Miren Begoña eZubero

    2014-01-01

    Full Text Available Background: The aim of screening for colorectal cancer is to improve prognosis by the detection of cancer at its early stages. In order to inform the decision on the specific test to be used in the population-based programme in the Basque Autonomous Region (Spain, we compared two immunochemical faecal occult blood quantitative tests (I-FOBT. Methods: Residents of selected study areas, aged 50-69 years, were invited to participate in the screening. Two tests based on latex agglutination (OC-Sensor and FOB Gold were randomly assigned to different study areas. A colonoscopy was offered to patients with a positive test result. The cut-off point used to classify a result as positive, according to manufacturer’s recommendations, was 100 ng/ml for both tests. Results: The invited population included 37,999 individuals. Participation rates were 61.8% (n=11,162 for OC-Sensor and 59.1% (n=11,786 for FOB Gold, (p=0.008. Positive rate for OC-Sensor was 6.6% (n=737 and 8.5% (n=1,002 for FOB Gold, (pConclusions: OC-Sensor test appears to be superior for I-FOBT based CRC screening, given its acceptance, ease of use, associated small number of errors and its screening accuracy. FOB-Gold on the other hand, has higher rate of positive values, with more colonoscopies performed, it shows higher detection incidence rates, but involves more false positives.

  18. The Conversion of Planned Colonoscopy to Sigmoidoscopy and the Effect of this Practice on the Measurement of Quality Indicators.

    Science.gov (United States)

    Beg, Sabina; Sansone, Stefano; Manguso, Francesco; Schembri, John; Patel, Jay; Thoufeeq, Mo; Corbett, Gareth; Ragunath, Krish

    2017-10-01

    A cecal intubation rate (CIR) of >90% is a well-accepted quality indicator of colonoscopy and is consequently monitored within endoscopy units. Endoscopists' desire to meet this target may mean that incomplete colonoscopies are recorded as flexible sigmoidoscopies. The aim of this study was to examine whether the conversion of requested colonoscopies is a clinically significant phenomenon and whether this impacts upon the measurement of quality indicators. A retrospective review of all flexible sigmoidoscopies performed between 1 January 2015 and 31 December 2015 at Nottingham University Hospitals, Sheffield Teaching Hospitals, and Cambridge University Hospitals was performed. Where a colonoscopy was requested but a flexible sigmoidoscopy performed, the patient's records and endoscopy reports were reviewed to determine whether this conversion was decided before the start of the procedure and documented. During the 12-month period, 6,839 flexible sigmoidoscopies were performed by 125 endoscopists. The original requests of 149 sigmoidoscopies could not be retrieved and were therefore excluded from this analysis. Of the 6,690 sigmoidoscopy requests reviewed, 2.8% (n=190) procedures were originally requested as a colonoscopy. On review of patient records, 85 conversions were appropriate according to pre-defined criteria. However, 105 conversions were deemed inappropriate, occurring in patients who had a valid documented indication for colonoscopy and had undergone full bowel preparation. The most common reasons cited included poor bowel preparation (n=37), technically challenging procedure (n=24), at the endoscopist's discretion based on clinical factors (n=21), and obstructing patology (n=8). A clear reason for conversion was not apparent in 11 cases. During the study period, 21,271 colonoscopies were performed and so conversions represent 0.45% of the total requests. When inappropriate conversions were included in individuals' performance data, 15 endoscopists fell

  19. Experimental study of virtual colonoscopy of simulated mass lesions in pig colon: comparison of CT and MR techniques

    International Nuclear Information System (INIS)

    Yang Xiujun; He Zhiyan; Tao Yonghao; Miao Jingtao; Chen Yuanjiong; Hu Yuansheng; Wang Linchuan

    2000-01-01

    Objective: To probe into the technique and diagnostic value of MR virtual colonoscopy (MRVC) compared with CT virtual colonoscopy (CTVC) and colonoscopy. Methods: Two approximately 25-cm-long-sections of fresh pit colon in vitro had 20 mass lesions created ranging from 3 mm to 12 mm in diameter. MR scanning, as well as CT scanning of the water- or air-insufflated colon was performed, and CT data were obtained with collimation of 3 mm at a pitch of 1.0 and reconstruction intervals of 1.5 mm. MRI data were acquired with the same matrix and reformatting slab, and with heavily T 2 -weighted fast spin-echo pulse sequences. Post processed image sets were performed by the same experienced doctor on a workstation using navigator software based on CT or MRI source imaging data. One section was also underwent electron colonoscopy. Results: MRVC and CTVC displayed colon morphology in a manner similar to colonoscopy. The sensitivity of MRVC and CTVC were all 100%, and the accuracy was 71.4% for MRVC and 100% for CTVC. With the combined analysis of the four-in-one multi-view images, they accurately demonstrated the site and size of lesions and distinguished the lesions from the artifacts such as small air bubbles, and the accuracy of MRVC was improved up to 100%. CTVC was better than MRVC (P<0.05), but both were inferior to colonoscopy in depicting mucosal details of the colon and lesions (P < 0.025). Conclusion: Virtual colonoscopy (CTVC or MRVC, the former appears better) provided noninvasive endoscope-like display of the colon, and permitted identification of colonic mass lesions as small as 3 mm in diameter, the diagnostic accuracy could be improved by combining with source images and other reformations

  20. Development of a colonoscopy add-on device for improvement of the intubation process

    Directory of Open Access Journals (Sweden)

    Litten JD

    2011-12-01

    Full Text Available Jonathan D Litten1, JungHun Choi2, David Drozek31Department of Mechanical Engineering; 2Department of Mechanical Engineering and Biomedical Engineering Program; 3College of Osteopathic Medicine, Department of Specialty Medicine, Ohio University, Athens, OH, USAAbstract: A colonoscopy add-on device has been developed to reduce intubation time without modification of the current colonoscope and peripheral devices. One of the main purposes of the system is to minimize trauma caused by the distal tip of the colonoscope. The detachable sensory fixture at the end of the distal tip measures the distance between the distal tip and the colon wall in three directions, and the actuation system attached at the base of the colonoscope controls the distal tip by rotating two dial knobs. The device controls the distal tip to minimize contact between the distal tip and the colon wall, and the distal tip ideally points out the next possible lumen. A compatibility test of the infrared sensory system was carried out, and the design of the actuation system was accomplished. The system is integrated and controlled by a microprocessor. The device was tested in a silicon colon and porcine intestine. The results showed that a colonoscopist successfully reached the cecum with the aid of the colonoscopy add-on device without significant contact between the colon wall and the distal tip. The colonoscopy aid device was very helpful for the novice colonoscopist.Keywords: colonoscope, infrared sensors, intubation, trauma, colonoscopy training model

  1. Referring Patients to Nurses: Outcomes and Evaluation of a Nurse Flexible Sigmoidoscopy Training Program for Colorectal Cancer Screening

    Directory of Open Access Journals (Sweden)

    Mark J Dobrow

    2007-01-01

    Full Text Available Colorectal cancer is a significant health burden. Several screening options exist that can detect colorectal cancer at an early stage, leading to a more favourable prognosis. However, despite years of knowledge on best practice, screening rates are still very low in Canada, particularly in Ontario. The present paper reports on efforts to increase the flexible sigmoidoscopy screening capacity in Ontario by training nurses to perform this traditionally physician-performed procedure. Drawing on American, British and local experience, a professional regulatory framework was established, and training curriculum and assessment criteria were developed. Training was initiated at Princess Margaret Hospital and Sunnybrook and Women’s College Health Sciences Centre in Toronto, Ontario. (During the study, Sunnybrook and Women’s College Health Sciences Centre was deamalgamated into two separate hospitals: Women’s College Hospital and Sunnybrook Health Sciences Centre. Six registered nurses participated in didactic, simulator and practical training. These nurses performed a total of 77 procedures in patients, 23 of whom had polyps detected and biopsied. Eight patients were advised to undergo colonoscopy because they had one or more neoplastic polyps. To date, six of these eight patients have undergone colonoscopy, one patient has moved out of the province and another patient is awaiting the procedure. Classifying the six patients according to the most advanced polyp histology, one patient had a negative colonoscopy (no polyps found, one patient’s polyps were hyperplastic, one had a tubular adenoma, two had advanced neoplasia (tubulovillous adenomas and one had adenocarcinoma. All these lesions were excised completely at colonoscopy. Overall, many difficulties were anticipated and addressed in the development of the training program; ultimately, the project was affected most directly by challenges in encouraging family physicians to refer patients to

  2. Cost-effectiveness modeling of colorectal cancer: Computed tomography colonography vs colonoscopy or fecal occult blood tests

    International Nuclear Information System (INIS)

    Lucidarme, Olivier; Cadi, Mehdi; Berger, Genevieve; Taieb, Julien; Poynard, Thierry; Grenier, Philippe; Beresniak, Ariel

    2012-01-01

    Objectives: To assess the cost-effectiveness of three colorectal-cancer (CRC) screening strategies in France: fecal-occult-blood tests (FOBT), computed-tomography-colonography (CTC) and optical-colonoscopy (OC). Methods: Ten-year simulation modeling was used to assess a virtual asymptomatic, average-risk population 50–74 years old. Negative OC was repeated 10 years later, and OC positive for advanced or non-advanced adenoma 3 or 5 years later, respectively. FOBT was repeated biennially. Negative CTC was repeated 5 years later. Positive CTC and FOBT led to triennial OC. Total cost and CRC rate after 10 years for each screening strategy and 0–100% adherence rates with 10% increments were computed. Transition probabilities were programmed using distribution ranges to account for uncertainty parameters. Direct medical costs were estimated using the French national health insurance prices. Probabilistic sensitivity analyses used 5000 Monte Carlo simulations generating model outcomes and standard deviations. Results: For a given adherence rate, CTC screening was always the most effective but not the most cost-effective. FOBT was the least effective but most cost-effective strategy. OC was of intermediate efficacy and the least cost-effective strategy. Without screening, treatment of 123 CRC per 10,000 individuals would cost €3,444,000. For 60% adherence, the respective costs of preventing and treating, respectively 49 and 74 FOBT-detected, 73 and 50 CTC-detected and 63 and 60 OC-detected CRC would be €2,810,000, €6,450,000 and €9,340,000. Conclusion: Simulation modeling helped to identify what would be the most effective (CTC) and cost-effective screening (FOBT) strategy in the setting of mass CRC screening in France.

  3. Rural Disparities in Treatment-Related Financial Hardship and Adherence to Surveillance Colonoscopy in Diverse Colorectal Cancer Survivors.

    Science.gov (United States)

    McDougall, Jean A; Banegas, Matthew P; Wiggins, Charles L; Chiu, Vi K; Rajput, Ashwani; Kinney, Anita Y

    2018-03-28

    Cancer survivors increasingly report financial hardship as a consequence of the high cost of cancer care, yet the financial experience of rural cancer survivors remains largely unstudied. The purpose of this study was to investigate potential rural disparities in the likelihood of financial hardship and nonadherence to surveillance colonoscopy. Individuals diagnosed with localized or regional colorectal cancer (CRC) between 2004-2012 were ascertained by the population-based New Mexico Tumor Registry. Participants completed a mailed questionnaire or telephone survey about their CRC survivorship experience, including treatment-related financial hardship and receipt of surveillance colonoscopy. Multivariable logistic regression was used to estimate adjusted odds ratios (OR) and 95% confidence intervals (CI). Compared to urban CRC survivors (n=168), rural CRC survivors (n=109) were slightly older, more likely to be married (65% v. 59%) and have an annual income financial hardship (OR 1.86, 95% CI 1.06-3.28) and nonadherence to surveillance colonoscopy guidelines (OR 2.28, 95% CI 1.07-4.85). In addition, financial hardship was independently associated with nonadherence to surveillance colonoscopy (OR 2.17, 95% CI 1.01-4.85). Substantial rural disparities in the likelihood of financial hardship and nonadherence to surveillance colonoscopy exist. Treatment-related financial hardship among rural CRC survivors may negatively impact adherence to guideline recommended follow-up care. Copyright ©2018, American Association for Cancer Research.

  4. An Automated Inpatient Split-dose Bowel Preparation System Improves Colonoscopy Quality and Reduces Repeat Procedures.

    Science.gov (United States)

    Yadlapati, Rena; Johnston, Elyse R; Gluskin, Adam B; Gregory, Dyanna L; Cyrus, Rachel; Werth, Lindsay; Ciolino, Jody D; Grande, David P; Keswani, Rajesh N

    2017-07-19

    Inpatient colonoscopy preparations are often inadequate, compromising patient safety and procedure quality, while resulting in greater hospital costs. The aims of this study were to: (1) design and implement an electronic inpatient split-dose bowel preparation order set; (2) assess the intervention's impact upon preparation adequacy, repeated colonoscopies, hospital days, and costs. We conducted a single center prospective pragmatic quasiexperimental study of hospitalized adults undergoing colonoscopy. The experimental intervention was designed using DMAIC (define, measure, analyze, improve, and control) methodology. Prospective data collected over 12 months were compared with data from a historical preintervention cohort. The primary outcome was bowel preparation quality and secondary outcomes included number of repeated procedures, hospital days, and costs. On the basis of a Delphi method and DMAIC process, we created an electronic inpatient bowel preparation order set inclusive of a split-dose bowel preparation algorithm, automated orders for rescue medications, and nursing bowel preparation checks. The analysis data set included 969 patients, 445 (46%) in the postintervention group. The adequacy of bowel preparation significantly increased following intervention (86% vs. 43%; P<0.01) and proportion of repeated procedures decreased (2.0% vs. 4.6%; P=0.03). Mean hospital days from bowel preparation initiation to discharge decreased from 8.0 to 6.9 days (P=0.02). The intervention resulted in an estimated 1-year cost-savings of $46,076 based on a reduction in excess hospital days associated with repeated and delayed procedures. Our interdisciplinary initiative targeting inpatient colonoscopy preparations significantly improved quality and reduced repeat procedures, and hospital days. Other institutions should consider utilizing this framework to improve inpatient colonoscopy value.

  5. [Screening for colorectal cancer in Italy, 2010 survey].

    Science.gov (United States)

    Zorzi, Manuel; Fedato, Chiara; Grazzini, Grazia; Sassoli de' Bianchi, Priscilla; Naldoni, Carlo; Pendenza, Melania; Sassatelli, Romano; Senore, Carlo; Visioli, Carmen Beatriz; Zappa, Marco

    2012-01-01

    We present the main results of the 2010 survey of the Italian screening programmes for colorectal cancer carried out by the National centre for screening monitoring (Osservatorio nazionale screening, ONS) on behalf of the Ministry of health. By the end of 2010, 105 programmes were active, 9 of which had been activated during the year, and 65% of Italians aged 50-69 years were residing in areas covered by organised screening programmes (theoretical extension). Twelve regions had their whole population covered. In the South of Italy and Islands, 5 new programmes were activated in 2010, with a theoretical extension of 29%. The majority of programmes employed the faecal occult blood test (FIT), while some adopted flexible sigmoidoscopy (FS) once in a lifetime and FIT for non-responders to FS. Overall, about 3,404,000 subjects were invited to undergo FIT, 47.2% of those to be invited within the year. The adjusted attendance rate was 48% and approximately 1,568,796 subjects were screened. Large differences in the attendance rate were observed among regions: 10% of programmes reported values lower than 24%. Positivity rate of FIT programmes was 5.5% at first screening (range: 1.6-11.3%) and 4.3% at repeat screening (range: 3.2-6.7%). The average attendance rate to total colonoscopy (TC) was 81.4% and in one region it was lower than 70%. Completion rate for total colonoscopy (TC) was 88.7%. Among the 740,281 subjects attending screening for the first time, the detection rate (DR) per 1,000 screened subjects was 2.4 for invasive cancer and 10.3 for advanced adenomas (AA - adenomas with a diameter ≥1 cm, with villous/tubulo-villous type or with high-grade dysplasia). As expected, the corresponding figures in the 843,204 subjects at repeat screening were lower (1.2‰ and 7.6‰ for invasive cancer and AA, respectively). The DR of cancer and adenomas increased with age and was higher among males. Many programmes reported some difficulties in guaranteeing TC in the

  6. Results of the FIT-based National Colorectal Cancer Screening Program in Slovenia.

    Science.gov (United States)

    Tepeš, Bojan; Bracko, Matej; Novak Mlakar, Dominika; Stefanovic, Milan; Stabuc, Borut; Frkovic Grazio, Snjezana; Maucec Zakotnik, Jozica

    2017-07-01

    Colorectal cancer (CRC) is one of the most common malignancies in the western world. We aimed to assess the first round of fecal immunochemical test (FIT)-based National CRC screening program (NCSP). In the NCSP conducted in Slovenia, a FIT and colonoscopy for those tested positive was used. The NCSP central unit sent 536,709 invitations to Slovenian residents age 50 to 69 years old between 2009 and 2011. The adherence rate was 56.9% (303,343 participants). FIT was positive in 6.2% (15,310) of the participants (men, 7.8%; women, 5.0%; P<0.01). A total of 13,919 unsedated colonoscopies were performed with the cecal intubation rate of 97.8%. The overall adenoma detection rate was 51.3% [95% confidence interval (CI), 50.5%-52.1%] of which 61.0% (95% CI, 59.9%-62.1%) was in men, and 39.1% (95% CI, 37.8%-40.3%) in women (P<0.01). The mean number of adenoma per positive colonoscopy was 1.94 (95% CI, 1.90-1.97). Adenoma, advanced adenoma, or cancer were found in 7732 (55.5%) colonoscopies. A total of 862 (6.2%) CRC cases were found. Only 161 (18.7%) carcinomas were situated in the right colon. A total of 597 (70.2%) patients with cancer were in the early clinical stages (N, negative; 194 22.8%) of all cancers were cured with only endoscopic resection. In the NCSP, CRC was found in 6.2% of those participants attending colonoscopy, with 81.3% of carcinomas found in the left colon. A localized clinical stage was found in 70.2% participants. In 22.8% of CRC patients, cancer was cured with endoscopic resection only.

  7. BOWEL PREPARATION BEFORE COLONOSCOPY FOR CHILDREN: comparison of efficacy of three different methods

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen DEHGHANI

    2015-12-01

    Full Text Available Background - Colonoscopy is an important diagnostic and therapeutic procedure. Adequate bowel preparation is mandatory. Several regimens were discussed in the literature. Among the drugs which has recently used, polyethylene glycol is one of the most popular agents. Objectives - The aim of this study was to compare efficacy of three different methods for 1 day preparation before colonoscopy. Methods - This study included children with the range of ages (2-21 who had an indication of colonoscopy. Exclusion criteria were based on the history of previous surgery, parental disagreement, and patients who did not use preparation protocol. Three methods for bowel preparation were studied: 1- Polyethylene glycol only; 2- Polyethylene glycol and bisacodyl suppositories; 3- Polyethylene glycol plus normal saline enema. Boston Bowel Preparation Score was used for evaluation of preparation. SPSS version 16.0 (Chicago, IL, USA were used for data analysis. Results - In this study 83 cases completed the bowel preparation completely. Acceptable bowel preparation was seen in 24 (85.71%, 36 (94.73%, and 14 (82.35% of cases in PEG, PEG + bisacodyl, and PEG + normal saline enema groups respectively. PEG + bisacodyl suppositories was more effective than PEG + normal saline for the preparation of the first segment ( P=0.05. For second and third segment of colon, BPPS score was higher in PEG + bisacodyl suppositories compared to other regimens, but this difference was not statistically significant. Conclusion - There was no significant difference between 1 day colonoscopy regimens in terms of bowel preparation score. Lowest score was seen in PEG + enema group compared to other group.

  8. BOWEL PREPARATION BEFORE COLONOSCOPY FOR CHILDREN: comparison of efficacy of three different methods.

    Science.gov (United States)

    Dehghani, Seyed Mohsen; Javaherizadeh, Hazhir; Haghighat, Mahmood; Imanieh, Mohammad-Hadi; Ghanbari, Saeed

    2015-12-01

    Colonoscopy is an important diagnostic and therapeutic procedure. Adequate bowel preparation is mandatory. Several regimens were discussed in the literature. Among the drugs which has recently used, polyethylene glycol is one of the most popular agents. The aim of this study was to compare efficacy of three different methods for 1 day preparation before colonoscopy. This study included children with the range of ages (2-21) who had an indication of colonoscopy. Exclusion criteria were based on the history of previous surgery, parental disagreement, and patients who did not use preparation protocol. Three methods for bowel preparation were studied: 1- Polyethylene glycol only; 2- Polyethylene glycol and bisacodyl suppositories; 3- Polyethylene glycol plus normal saline enema. Boston Bowel Preparation Score was used for evaluation of preparation. SPSS version 16.0 (Chicago, IL, USA) were used for data analysis. In this study 83 cases completed the bowel preparation completely. Acceptable bowel preparation was seen in 24 (85.71%), 36 (94.73%), and 14 (82.35%) of cases in PEG, PEG + bisacodyl, and PEG + normal saline enema groups respectively. PEG + bisacodyl suppositories was more effective than PEG + normal saline for the preparation of the first segment ( P=0.05). For second and third segment of colon, BPPS score was higher in PEG + bisacodyl suppositories compared to other regimens, but this difference was not statistically significant. There was no significant difference between 1 day colonoscopy regimens in terms of bowel preparation score. Lowest score was seen in PEG + enema group compared to other group.

  9. Factors influencing change in clinical practice: A qualitative evaluation of the implementation of the quality improvement in colonoscopy study.

    Science.gov (United States)

    Rajasekhar, Praveen T; Rees, Colin J; Nixon, Catherine; East, James E; Brown, Sally

    2016-01-01

    The quality improvement in colonoscopy study was a region wide service improvement study to improve adenoma detection rate at colonoscopy by implementing evidence into routine colonoscopy practice. Implementing evidence into clinical practice can be challenging. The purpose of this paper is to perform a qualitative interview study to evaluate factors that influenced implementation within the study. Semi-structured interviews were conducted with staff in endoscopy units taking part in the quality improvement in colonoscopy study, after study completion. Units and interviewees were purposefully sampled to ensure a range of experiences was represented. Interviews were conducted with 11 participants. Key themes influencing uptake of the quality improvement in colonoscopy evidence bundle included time, study promotion, training, engagement, positive outcomes and modifications. Areas within themes were increased awareness of quality in colonoscopy (QIC), emphasis on withdrawal time and empowerment of endoscopy nurses to encourage the use of quality measures were positive outcomes of the study. The simple, visible study posters were reported as useful in aiding study promotion. Feedback sessions improved engagement. Challenges included difficulty arranging set-up meetings and engaging certain speciality groups. This evaluation suggests that methods to implement evidence into clinical practice should include identification and empowerment of team members who can positively influence engagement, simple, visible reminders and feedback. Emphasis on timing of meetings and strategies to engage speciality groups should also be given consideration. Qualitative evaluations can provide important insights into why quality improvement initiatives are successful or not, across different sites.

  10. Temporal trends and variability of colonoscopy performance in a gastroenterology practice.

    Science.gov (United States)

    le Clercq, Chantal M C; Mooi, Rick J; Winkens, Bjorn; Salden, Bouke N H; Bakker, C Minke; van Nunen, Annick B; Keulen, Eric P T; de Ridder, Rogier J; Masclee, Ad A M; Sanduleanu, Silvia

    2016-03-01

    Quality measures for colonoscopy are operator dependent and vary. It is unclear whether quality measures change over time. In this study, time-dependent variation in colonoscopy performance was examined in a gastroenterology practice. Colonoscopy and histopathology records that were collected at three hospitals (one university and two non-university hospitals) over three time periods (2007, 2010, and 2013) were reviewed. Data from colonoscopists performing at least 100 procedures per year were analyzed. Inter-colonoscopist variation in performance (i. e. adjusted cecal intubation rate [aCIR], adenoma detection rate [ADR], advanced ADR, mean adenomas per procedure [MAP], proximal ADR, nonpolypoid ADR, and serrated polyp detection rate) were examined using coefficients of variation. Logistic regression analyses were also performed, adjusting for covariates. A total of 23 colonoscopists performing 6400 procedures were included. Overall, the mean aCIR, ADR, MAP, and proximal ADR improved significantly over time, from 91.9 %, 22.5 %, 0.37, and 10.2 % in 2007 to 95.3 %, 25.8 %, 0.45, and 13.4 %, respectively, in 2013 (P gastroenterology clinical practice. Core quality measures improved over time, mainly through improvement of the lower performers. Measurement of inter-colonoscopist variation in performance helps to identify factors that stimulate or hinder performance, and forms the basis for interventions. http://www.trialregister.nl. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Impact of Fellowship Training Level on Colonoscopy Quality and Efficiency Metrics.

    Science.gov (United States)

    Bitar, Hussein; Zia, Hassaan; Bashir, Muhammad; Parava, Pratyusha; Hanafi, Muhammad; Tierney, William; Madhoun, Mohammad

    2018-04-18

    Previous studies have described variable effects of fellow involvement on the adenoma detection rate (ADR), but few have stratified this effect by level of training. We aimed to evaluate the "fellow effect" on multiple procedural metrics including a newly defined adenoma management efficiency index, which may have a role in documenting colonoscopy proficiency for trainees. We also describe the impact of level of training on moderate sedation use. We performed a retrospective review of 2024 patients (mean age 60.9 ± 10. 94% males) who underwent outpatient colonoscopy between June 2012 and December 2014 at our Veterans Affairs Medical Center. Colonoscopies were divided into 5 groups. The first 2 groups were first year fellows in the first 6 months and last 6 months of the training year. Second and third year fellows and attending only procedures accounted for one group each. We collected data on doses of sedatives used, frequency of adjunctive agent use, procedural times as well as location, size and histology of polyps. We defined the adenoma management efficiency index as average time required per adenoma resected during withdrawal. 1675 colonoscopies involved a fellow. 349 were performed by the attending alone. There was no difference in ADR between fellows according to level of training (P=0.8), or between fellows compared with attending-only procedures (P=0.67). Procedural times decreased consistently during training, and declined further for attending only procedures. This translated into improvement in the adenoma management efficiency index (fellow groups by ascending level of training 23.5 minutes vs 18.3 minutes vs 13.7 minutes vs 13.4 minutes vs attending group 11.7 minutes; PEfficiency of detecting and resecting polyps improved throughout training without reaching attending level. Fellow involvement led to greater use of moderate sedation, which may relate to a longer procedure duration and an evolving experience in endoscopic technique. Copyright

  12. A comparative study of faecal occult blood kits in a colorectal cancer screening program in a cohort of healthy construction workers.

    LENUS (Irish Health Repository)

    Shuhaibar, M

    2012-02-01

    BACKGROUND: The incidence of colorectal cancer (CRC) has been increasing. We evaluated uptake rates and outcomes of faecal immunochemical test (FIT) and Guaiac test (gFOBT) kits as part of a two-step CRC screening. METHODS: A 3-year CRC screening program for a defined population of construction workers was conducted. Those satisfying the inclusion criteria were provided with gFOBT or FIT kits. Individuals testing positive were invited for a colonoscopy. RESULTS: A total of 909 faecal testing kits were distributed. Age range was 53-60 years. Compliance rate was higher for FIT (58.3%) as compared to gFOBT (46.7%) (p = 0.0006). FIT detected adenomatous polyps and CRC in 37.5 and 25%, respectively, whereas; gFOBT detected 23.5 and 18%. Colonoscopies were normal in 53 and 25% tested positive by gFOBT and FIT, respectively (p = 0.016). CONCLUSION: The FIT was more cost-effective when compared with gFOBT with higher return rate, sensitivity and specificity. A comparative study of faecal occult blood kits in a CRC screening program in a healthy cohort of construction workers.

  13. Two-day bowel preparation with polyethylene glycol 3350 and bisacodyl: a new, safe, and effective regimen for colonoscopy in children.

    Science.gov (United States)

    Phatak, Uma P; Johnson, Susanne; Husain, Sohail Z; Pashankar, Dinesh S

    2011-07-01

    To assess the safety, efficacy, and acceptance of a 2-day bowel preparation with polyethylene glycol (PEG) 3350 without electrolytes and bisacodyl for colonoscopy in children. In a prospective study, 111 children of mean age 11.9 years were given 2 g/kg of PEG and a 5-mg tablet of bisacodyl daily for 2 days before colonoscopy. Stool frequency, consistency, and adverse effects were monitored for the duration of the bowel preparation. Compliance and quality of colonic preparation were assessed on the day of the colonoscopy. The average daily stool frequency increased from a baseline of 2, to 4* on day 1, and 6.5* on day 2 of the bowel preparation (*P PEG and bisacodyl is safe, effective, and well accepted for colonoscopy in children without any major adverse effects.

  14. Colonoscopy

    Science.gov (United States)

    ... better chance of curing the disease. Screening for Colon and Rectal Cancer Your doctor will recommend screening for colon and rectal cancer —also called colorectal cancer—starting at age 50 ...

  15. Endovascular Treatment of Active Splenic Bleeding After Colonoscopy: A Systematic Review of the Literature

    International Nuclear Information System (INIS)

    Corcillo, Antonella; Aellen, Steve; Zingg, Tobias; Bize, Pierre; Demartines, Nicolas; Denys, Alban

    2013-01-01

    Purpose: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. Methods: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reported case of PSAE) was performed and the three types of treatment compared. Results: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8 %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74 %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44 %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. Conclusion: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic

  16. Risks and benefits of colonoscopy in patients aged 80 and older: A prospective study

    Directory of Open Access Journals (Sweden)

    Edson Jurado da Silva

    2013-04-01

    Full Text Available Objective: this study aims to compare colonoscopy results in patients aged 50-79 and those aged 80 and older. Patients and Methods: a total of 533 diagnostic colonoscopies performed from August 2011 to January 2012 were evaluated in a prospective study analyzing age, ASA classification, co- morbidities, endoscopic findings, time to reach the cecum, number of complete examina- tions, difficulties and complications. Chi-square test was used to compare categorical data whereas Student's t test to compare means. A p value 0.05, ASA > 2 difficult examination: 41 (20% versus 6 (60% p 0.05. Complete colonoscopy in 450 (94% versus 45 (83%, p 0.05 Time to reach the cecum was 39 ± 10 minutes for difficult procedures and 13 ± 9 for the easy ones. Conclusion: age 80 and older is associated with more adverse events during colonoscopy. Resumo: Objetivo: avaliar riscos em colonoscopia após 80 anos de idade. Pacientes e métodos: entre agosto de 2011 e janeiro de 2012 realizamos colonoscopias em 533 pacientes. Grupo A: idade entre 50 e 79 e Grupo B > de 80 anos. Parâmetros analisados: ASA, comorbidades, achados endoscópicos, tempo de chegada ao ceco, número de exames com- pletos, dificuldade e complicações. Usamos teste Qui-quadrado para comparar proporção e teste t de Student para média e desvio padrão. p 0,05 > ASA 2 difícil 41 (20% e 6 (60% p 0.05. Exame completo 450 (94% e 45 (83% p 0,05. Tempo em minutos 39 ± 10 para os difíceis e 13 ± 9 para os fáceis. Conclusão: a idade de 80 anos constitui um risco para a realização de colonoscopia. Keywords: Colonoscopy, Risks, Complications, Older age, Elderly, Palavras-chave: Colonoscopia, Riscos, Complicações, Idade avançada, Terceira idade

  17. Endovascular Treatment of Active Splenic Bleeding After Colonoscopy: A Systematic Review of the Literature

    Energy Technology Data Exchange (ETDEWEB)

    Corcillo, Antonella, E-mail: antonella.corcillo@chuv.ch [Centre Hospitalier Universitaire Vaudois (CHUV), Departement de Medecine Interne (Switzerland); Aellen, Steve, E-mail: steve.aellen@hopitalvs.ch; Zingg, Tobias [Centre Hospitalier Universitaire Vaudois (CHUV), Service de Chirurgie Viscerale (Switzerland); Bize, Pierre [Centre Hospitalier Universitaire Vaudois (CHUV), Departement de Radiologie Interventionnelle (Switzerland); Demartines, Nicolas [Centre Hospitalier Universitaire Vaudois (CHUV), Service de Chirurgie Viscerale (Switzerland); Denys, Alban [Centre Hospitalier Universitaire Vaudois (CHUV), Departement de Radiologie Interventionnelle (Switzerland)

    2013-10-15

    Purpose: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. Methods: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reported case of PSAE) was performed and the three types of treatment compared. Results: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8 %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74 %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44 %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. Conclusion: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic

  18. Sensitivity of 2-[18F]fluoro-2-deoxyglucose positron emission tomography for advanced colorectal neoplasms: a large-scale analysis of 7505 asymptomatic screening individuals.

    Science.gov (United States)

    Sekiguchi, Masau; Kakugawa, Yasuo; Terauchi, Takashi; Matsumoto, Minori; Saito, Hiroshi; Muramatsu, Yukio; Saito, Yutaka; Matsuda, Takahisa

    2016-12-01

    The sensitivity of 2-[ 18 F]fluoro-2-deoxyglucose positron emission tomography (FDG-PET) for advanced colorectal neoplasms among healthy subjects is not yet fully understood. The present study aimed to clarify the sensitivity by analyzing large-scale data from an asymptomatic screening population. A total of 7505 asymptomatic screenees who underwent both FDG-PET and colonoscopy at our Cancer Screening Division between February 2004 and March 2013 were analyzed. FDG-PET and colonoscopy were performed on consecutive days, and each examination was interpreted in a blinded fashion. The results of the two examinations were compared for each of the divided six colonic segments, with those from colonoscopy being set as the reference. The relationships between the sensitivity of FDG-PET and clinicopathological features of advanced neoplasms were also evaluated. Two hundred ninety-one advanced neoplasms, including 24 invasive cancers, were detected in 262 individuals. Thirteen advanced neoplasms (advanced adenomas) were excluded from the analysis because of the coexistence of lesions in the same colonic segment. The sensitivity, specificity, and positive and negative predictive values of FDG-PET for advanced neoplasms were 16.9 % [95 % confidence interval (CI) 12.7-21.8 %], 99.3 % (95 % CI 99.2-99.4 %), 13.5 % (95 % CI 10.1-17.6 %), and 99.4 % (95 % CI 99.3-99.5 %), respectively. The sensitivity was lower for lesions with less advanced histological grade, of smaller size, and flat-type morphology, and for those located in the proximal part of the colon. FDG-PET is believed to be difficult to use as a primary screening tool in population-based colorectal cancer screening because of its low sensitivity for advanced neoplasms. Even when it is used in opportunistic cancer screening, the limit of its sensitivity should be considered.

  19. Results of faecal immunochemical test for colorectal cancer screening, in average risk population, in a cohort of 1389 subjects.

    Science.gov (United States)

    Miuţescu, Bogdan; Sporea, Ioan; Popescu, Alina; Bota, Simona; Iovănescu, Dana; Burlea, Amelia; Mos, Liana; Miuţescu, Eftimie

    2013-01-01

    The aim of this study is to evaluate the usefulness of the fecal immunochemical test (FIT) in colorectal cancer screening, detection of precancerous lesions and early colorectal cancer. The study evaluated asymptomatic patients with average risk (no personal or family antecedents of polyps or colorectal cancer), aged between 50 and 74 years. The presence of the occult haemorrhage was tested with the immunochemical faecal test Hem Check 1 (Veda Lab, France). The subjects were not requested to have any dietary or drug restrictions. Colonoscopy was recommended in all subjects that tested positive. In our study, we had a total of 1389 participants who met the inclusion criteria, with a mean age of 61.2 ± 12.8 years, 565 (40.7%) men and 824 (59.3%) women. FIT was positive in 87 individuals (6.3%). In 57/87 subjects (65.5%) with positive FIT, colonoscopy was performed, while the rest of the subjects refused or delayed the investigation. A number of 5 (8.8%) patients were not able to have a complete colonoscopy, due to neoplastic stenosis. The colonoscopies revealed in 10 cases (0.7%) cancer, in 29 cases (2.1%) advanced adenomas and in 15 cases (1.1%) non advanced adenomas from the total participants in the study. The colonoscopies performed revealed a greater percentage of advanced adenomas in the left colon compared to the right colon, 74.1% vs. 28.6% (p<0.001). In our study, FIT had a positivity rate of 6.3%. The detection rate for advanced neoplasia was 2.8% (0.7% for cancer, 2.1% for advanced adenomas) in our study group. Adherence to colonoscopy for FIT-positive subjects was 65.5%.

  20. COLONOSCOPY: RANDOMIZED COMPARATIVE STUDY OF INSUFFLATION WITH CARBON DIOXIDE VERSUS AIR

    Science.gov (United States)

    DE-QUADROS, Luiz Gustavo; KAISER-JÚNIOR, Roberto Luiz; FELIX, Valter Nilton; VILLAR, Lucio; CAMPOS, Josemberg Marins; NOGUEIRA, Vinicius Quintiliano Moutinho; TEIXEIRA, André; ZOTARELLI-FILHO, Idiberto José

    2017-01-01

    ABSTRACT Background: In Brazil, an increasing number of people are submitted to colonoscopy, either for screening or for therapeutic purposes. Aim: To evaluate whether there are advantages of using carbon dioxide (CO2) over air for insufflation. Methods: Two hundred and ten of 219 patients were considered eligible for this study and were randomized into two groups according to the gas insufflation used: Air Group (n=104) and CO2 Group (n=97). The study employed a double-blind design. Results: The Air and CO2 Groups were similar in respect to bowel preparation evaluated using the Boston scale, age, gender, previous surgery, maneuvers necessary for the advancement of the device, and presence of polyps, tumors or signs of diverticulitis. However, “waking up with pain” and “pain at discharge” were more prevalent in the Air Group, albeit not statistically significant, with post-exam bloating seen only in the Air Group. The responses to a questionnaire, applied to analyze the late post-exam period, showed more comfort with the use of CO2. Conclusions: The use of CO2 is better than air as it avoids post-examination bloating, thereby providing greater comfort to patients. PMID:29019557

  1. A feasibility study of optical flow-based navigation during colonoscopy

    NARCIS (Netherlands)

    van der Stap, N.; Reilink, Rob; Misra, Sarthak; Broeders, Ivo Adriaan Maria Johannes; van der Heijden, Ferdinand

    In this study, it was shown that using the optical flow and the focus of expansion, obtained from the monocular camera at the beginning of a colonoscope, (semi-)automated steering of flexible endoscopes might become possible. This automation might help to increase colonoscopy efficiency, but is also

  2. Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Takashi; Urata, Joji [Diagnostic Imaging Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Mitsuzaki, Katsuhiko; Matsuda, Katsuhiko; Kawakami, Megumi [Medical Examination Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Utsunomiya, Daisuke; Yamamura, Sadahiro; Yamashita, Yasuyuki [Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)], e-mail: utsunomi@kumamoto-u.ac.jp

    2012-09-15

    Background: Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. Purpose: To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. Material and Methods: We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Results: Detection sensitivity for flat polyps was 31.3 %, 44.4 %, and 87.5 % for lesions measuring 2-3 mm, 4-5 mm, and {>=}6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6 %, 79.0 %, and 91.7 %. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. Conclusion: CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.

  3. Safety of a 1-Day Polyethylene Glycol 3350 Bowel Preparation for Colonoscopy in Children.

    Science.gov (United States)

    Sahn, Benjamin; Chen-Lim, Mei Lin; Ciavardone, Denise; Farace, Lisa; Jannelli, Frances; Nieberle, Megan; Ely, Elizabeth; Zhang, Xuemei; Kelsen, Judith; Puma, Anita; Mamula, Petar

    2016-07-01

    Electrolyte-free polyethylene glycol powder (PEG-3350) has been widely used for colonoscopy preparation (prep); however, limited safety data on electrolyte changes exists with 1-day prep regimens. The primary aim of this study was to determine the proportion of patients with significant serum chemistry abnormalities before and at the time of colonoscopy. Secondary aims included evaluation of prep tolerance and bowel cleansing efficacy. We performed a prospective descriptive observational study of pediatric patients scheduled for outpatient colonoscopy who received our standard 1-day, weight-based 4 g/kg PEG-3350 prep with a single stimulant laxative dose and had serum chemistry testing within 60 days before and at the time of colonoscopy. A standardized bowel cleanliness tool (Aronchick scale) was completed by the endoscopist. One hundred fifty-five patients had serum electrolytes data pre- and postprep. Comparison of each patient's chemistries demonstrated statistical equivalence with the 1 exception of blood urea nitrogen levels (P = 0.56). Hypokalemia was detected postprep in 37 subjects (24%), but none had a serum level <3.3 mmol/L, which was deemed to be of no clinical significance. Five patients were hypoglycemic post prep; 3 were 7 years or younger (P = 0.02). The colon cleanliness rating was excellent or good in 77% and suboptimal in 23% of patients. A 1-day, weight-based PEG-3350 bowel prep in children appears safe. Changes in electrolyte levels and renal function were not clinically significant. Children of 7 years or younger seem to be at a higher risk of hypoglycemia compared with older children.

  4. Intraoperative radionuclide study and colonoscopy in gastrointestinal hemorrhage

    International Nuclear Information System (INIS)

    Navab, F.; Westbrook, K.C.; Slaton, G.; Boyd, C.M.

    1985-01-01

    Tc-99m labeled red cell imaging is used in the diagnosis and localization of gastrointestinal hemorrhage. A patient in whom a preoperative scan was positive in the right paraumbilical region is discussed. Intraoperative Tc-99m labeled red cell imaging was used in conjunction with colonoscopy, and the site of active bleeding was found in the proximal transverse colon, which had been displaced downward because of adhesions

  5. Effectiveness of Sodium Picosulfate/Magnesium Citrate (PICO) for Colonoscopy Preparation

    Science.gov (United States)

    Suh, Wu Seok; Jeong, Jin Sik; Kim, Dong Sik; Kim, Sang Woo; Kwak, Dong Min; Hwang, Jong Seong; Kim, Hyun Jin; Park, Man Woo; Shim, Min Chul; Koo, Ja-Il; Kim, Jae Hwang; Shon, Dae Ho

    2014-01-01

    Purpose Bowel preparation with sodium phosphate was recently prohibited by the U.S. Food and Drug Administration. Polyethylene glycol (PEG) is safe and effective; however, it is difficult to drink. To identify an easy bowel preparation method for colonoscopy, we evaluated three different bowel preparation regimens regarding their efficacy and patient satisfaction. Methods In this randomized, comparative study, 892 patients who visited a secondary referral hospital for a colonoscopy between November 2012 and February 2013 were enrolled. Three regimens were evaluated: three packets of sodium picosulfate/magnesium citrate (PICO, group A), two packets of PICO with 1 L of PEG (PICO + PEG 1 L, group B), and two packets of PICO with 2 L of PEG (PICO + PEG 2 L, group C). A questionnaire survey regarding the patients' preference for the bowel preparation regimen and satisfaction was conducted before the colonoscopies. The quality of bowel cleansing was scored by the colonoscopists who used the Aronchick scoring scale and the Ottawa scale. Results The patients' satisfaction rate regarding the regimens were 72% in group A, 64% in group B, and 45.9% in group C. Nausea and abdominal bloating caused by the regimens were more frequent in group C than in group A or group B (P < 0.01). Group C showed the lowest preference rate compared to the other groups (P < 0.01). Group C showed better right colon cleansing efficacy than group A or group B. Conclusion Group A exhibited a better result than group B or group C in patient satisfaction and preference. In the cleansing quality, no difference was noted between groups A and C. PMID:25360429

  6. Patient anxiety before invasive diagnostic examinations: coronarography, arteriography, and colonoscopy

    International Nuclear Information System (INIS)

    Gryz, J.; Izdebski, P.

    2005-01-01

    The aim of this study was to answer such questions as: 1) Do patients show higher levels of anxiety (cognitive and/or physiological rates) before invasive examinations? 2) Does the type of invasive diagnostic examinations influence the patients' anxiety level? 3) Does the level of the patients' knowledge about coronarography, arteriography, or colonoscopy cause differences in their anxiety levels? The study was conducted at the Military Clinical Hospital in Bydgoszcz in the Departments of Gastroenteriology, Radiology, and Cardiology and in the Clinic of General Surgery, Chest and Vessels, and lasted seven months, from August 2002 to February 2003. 93 patients (29 women and 64 men) qualifying for different invasive examinations participated in the study. The participants were divided in three groups. The first consisted of patients awaiting coronarography, the second arteriography of the lower limbs, and the third colonoscopy. The participants were chosen on the basis of medical criteria. A structured interview was used to assess their levels of knowledge about the invasive examination they were to undergo. Anxiety was assessed with the Inventory of State and Trait Anxiety and by blood pressure measurement. On the basis of the obtained data we conclude that patients awaiting invasive examinations have higher physiological anxiety rates and that the type of invasive examination significantly influences patient anxiety levels. The type of examination did not differentiate patients according to their cognitive rates of anxiety: the level was average. The levels of patient knowledge about coronarography, colonoscopy, and arteriography did not cause any differences in physiological and cognitive rates of anxiety. The authors conclude that the cognitive aspects of anxiety do not influence the way patients experience physiological anxiety before invasive examinations. (author)

  7. Closed loop control of sedation for colonoscopy using the Bispectral Index

    NARCIS (Netherlands)

    Leslie, K.; Absalom, A.; Kenny, G. N. C.

    Sixteen patients undergoing colonoscopy were sedated with propofol using a closed-loop control system guided by the Bispectral Index (BIS). Propofol administration, via a target-controlled infusion, was controlled by a proportional-integral-differential control algorithm. The median (range) propofol

  8. Towards continuous improvement of endoscopy standards: Validation of a colonoscopy assessment form.

    LENUS (Irish Health Repository)

    2012-02-01

    Aim: Assessment of procedural colonoscopy skills is an important and topical. The aim of this study was to develop and validate a competency-based colonoscopy assessment form that would be easy to use, suitable for the assessment of junior and senior endoscopists and potentially be a useful instrument to detect differences in performance standards following different training interventions. Method: A standardised assessment form was developed incorporating a checklist with dichotomous yes\\/no responses and a global assessment section incorporating several different elements. This form was used prospectively to evaluate colonoscopy cases during the period of the study in several university teaching hospitals. Results were analysed using ANOVA with Bonferroni corrections for post-hoc analysis. Results: 81 procedures were assessed, performed by eight consultant and 19 trainee endoscopists. There were no serious errors. When divided into three groups based on previous experience (novice, intermediate and expert) the assessment form demonstrated statistically significant differences between all three groups (p<0.05). When separate elements were taken into account, the global assessment section was a better discriminator of skill level than the checklist. Conclusion: This form is a valid, easy to use assessment method. We intend to use it to assess the value of simulator training in trainee endoscopists. It also has the potential to be a useful training tool when feedback is given to the trainee.

  9. Polyethylene glycol powder solution versus senna for bowel preparation for colonoscopy in children.

    Science.gov (United States)

    Terry, Natalie A; Chen-Lim, Mei Lin; Ely, Elizabeth; Jatla, Muralidhar; Ciavardone, Denise; Esch, Salina; Farace, Lisa; Jannelli, Frances; Puma, Anita; Carlow, Dean; Mamula, Petar

    2013-02-01

    Safety and effectiveness of large-volume polyethylene glycol-based solution (PEG-ES) have been documented, but the taste and volume can be barriers to successful colonoscopy preparation. Efficacy and safety of small-volume electrolyte-free (PEG-P) preparation (Miralax) for colonoscopy preparation have been rarely studied, although presently used at many pediatric centers. The primary objective of the present study was to determine whether PEG-P results in a more efficacious and safe colonoscopy preparation as compared with senna. The study design was prospective, randomized, and single-blinded. Patients ages 6 to 21 years were randomized to a 2-day clean-out regimen of PEG-P at a dose of 1.5 g/kg divided twice per day for 2 days versus senna 15 mL daily (ages 6-12) or 30 mL daily (ages 12-21) for 2 days. Both preparations required 1 day of clear liquids whereas senna preparation required an additional day of full liquid diet. A blinded endoscopist graded the quality of preparation with a standardized cleanliness tool (Aronchick scale). Serum chemistry panels were obtained. Patients or parents rated symptoms and ease of preparation. The anticipated number of subjects was 166; however, the interim analysis demonstrated inferiority of senna preparation. Thirty patients were evaluated in the present study. Of the patients in the PEG-P arm, 88% (14/16) received an excellent/good score compared with 29% (4/14), with the senna preparation (P = 0.0022). Both preparations were well-tolerated by patient-graded ease of preparation. Demographics and laboratory values did not differ significantly across the 2 groups. No serious adverse events were noted. PEG-P is an effective colonoscopy preparation whereas senna preparation was insufficient. Both were well-tolerated and appear safe in a pediatric population.

  10. The cost-effectiveness of training US primary care physicians to conduct colorectal cancer screening in family medicine residency programs.

    Science.gov (United States)

    Edwardson, Nicholas; Bolin, Jane N; McClellan, David A; Nash, Philip P; Helduser, Janet W

    2016-04-01

    Demand for a wide array of colorectal cancer screening strategies continues to outpace supply. One strategy to reduce this deficit is to dramatically increase the number of primary care physicians who are trained and supportive of performing office-based colonoscopies or flexible sigmoidoscopies. This study evaluates the clinical and economic implications of training primary care physicians via family medicine residency programs to offer colorectal cancer screening services as an in-office procedure. Using previously established clinical and economic assumptions from existing literature and budget data from a local grant (2013), incremental cost-effectiveness ratios are calculated that incorporate the costs of a proposed national training program and subsequent improvements in patient compliance. Sensitivity analyses are also conducted. Baseline assumptions suggest that the intervention would produce 2394 newly trained residents who could perform 71,820 additional colonoscopies or 119,700 additional flexible sigmoidoscopies after ten years. Despite high costs associated with the national training program, incremental cost-effectiveness ratios remain well below standard willingness-to-pay thresholds under base case assumptions. Interestingly, the status quo hierarchy of preferred screening strategies is disrupted by the proposed intervention. A national overhaul of family medicine residency programs offering training for colorectal cancer screening yields satisfactory incremental cost-effectiveness ratios. However, the model places high expectations on primary care physicians to improve current compliance levels in the US. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Quality of colonoscopy performance among gastroenterology and surgical trainees: a need for common training standards for all trainees?

    Science.gov (United States)

    Leyden, J E; Doherty, G A; Hanley, A; McNamara, D A; Shields, C; Leader, M; Murray, F E; Patchett, S E; Harewood, G C

    2011-11-01

    Cecal intubation and polyp detection rates are objective measures of colonoscopy performance. Minimum cecal intubation rates greater than 90% have been endorsed by the American Society for Gastrointestinal Endoscopy (ASGE) and the Joint Advisory Group (JAG) UK. Performance data for medical and surgical trainee endoscopists are limited, and we used endoscopy quality parameters to compare these two groups. Retrospective review of all single-endoscopist colonoscopies done by gastroenterology and surgical trainees ("registrars," equivalent to fellows, postgraduate year 5) with more than two years' endoscopy experience, in 2006 and 2007 at a single academic medical center. Completion rates and polyp detection rates for endoscopists performing more than 50 colonoscopies during the study period were audited. Colonoscopy withdrawal time was prospectively observed in a representative subset of 140 patients. Among 3079 audited single-endoscopist colonoscopies, seven gastroenterology trainees performed 1998 procedures and six surgery trainees performed 1081. The crude completion rate was 82%, 84% for gastroenterology trainees and 78% for surgery trainees (P gastroenterology trainees, and 84% for surgical trainees (P gastroenterology and surgical trainees, respectively (P gastroenterology trainees 14% and surgical trainees 9% (P = 0.0065). In the prospectively audited procedures, median withdrawal time was greater in the gastroenterology trainee group and polyp detection rates correlated closely with withdrawal time (r = 0.99). The observed disparity in endoscopic performance between surgical and gastroenterology trainees suggests the need for a combined or unitary approach to endoscopy training for specialist medical and surgical trainees. © Georg Thieme Verlag KG Stuttgart · New York.

  12. [Reasearch progress in health economic evaluation of colorectal cancer screening in China].

    Science.gov (United States)

    Huang, Huiyao; Shi, Jufang; Dai, Min

    2015-08-01

    Burden of colorectal cancer is rising in China. More attention and financial input have been paid to it by central government that colorectal cancer screening program has been carried out recently in many areas in China. Diversity of screening strategies and limited health resources render selecting the best strategy in a population-wide program a challenging task that economy was also required to be considered except safety and efficacy. To provide a reference for the subsequent further economic evaluation, here we reviewed the evidence available on the economic evaluation of colorectal cancer screening in China. Meanwhile, information related to screening strategies, participation and mid-term efficacy of screening, information and results on economic evaluation were extracted and summarized. Three of the four studies finally included evaluated strategies combining immunochemical fecel occult blood test (iFOBT) with high-risk factor questionnaire as initial screening, colonoscopy as diagnostic screening. There was a consensus regarding the efficacy and effectiveness of screening compared to no screening. Whereas the lack and poor comparability between studies, multi-perspective and multi-phase economic evaluation of colorectal cancer screening is needed, relying on current population-based screening program to conduct a comprehensive cost accounting.

  13. The impact of diet liberalization on bowel preparation for colonoscopy.

    Science.gov (United States)

    Walter, James; Francis, Gloria; Matro, Rebecca; Kedika, Ramalinga; Grosso, Rachael; Keith, Scott W; Kastenberg, David

    2017-04-01

    Background and study aims  Dietary restrictions are integral to colonoscopy preparation and impact patient satisfaction. Utilizing split-dose, lower-volume polyethylene glycol 3350-electrolyte solution (PEG-ELS), this study compared colon preparation adequacy of a low-residue diet to clear liquids using a validated grading scale. Patients and methods  This was a prospective, randomized, single-blinded, single-center non-inferiority study evaluating diet the day prior to outpatient colonoscopy. Subjects were randomized to a Low-Residue diet for breakfast and lunch, or Clears only. All subjects received split dose PEG-ELS. The primary endpoint was preparation adequacy using the Boston Bowel Preparation Scale (BBPS), with adequate defined as a score > 5. Secondary endpoints included mean BBPS scores for the entire colon and individual segments, satisfaction, adverse events, polyp and adenoma detection rates, and impact on sleep and daily activities. Results  Final analysis included 140 subjects, 72 assigned to Clears and 68 to Low-Residue. The Low-Residue diet was non-inferior to Clears (risk difference = - 5.08 %, P  = 0.04) after adjusting for age. Mean colon cleansing scores were not significantly different overall and for individual colonic segments. Satisfaction with the Low-Residue diet was significantly greater ( P  = 0.01). The adenoma detection rate was not statistically significantly different between study groups, but the number of adenomas detected was significantly greater with Clears ( P  = 0.01). Adverse events and impact on sleep and activities did not differ significantly between diet arms. Conclusions  A low-residue diet for breakfast and lunch the day prior to colonoscopy was non-inferior to clear liquids alone for achieving adequate colon cleansing when using split dose PEG-ELS.

  14. Safety Incident Management Team Report for NIMLT Case 50796

    LENUS (Irish Health Repository)

    2017-01-17

    This is a report on the management of a patient safety incident involving BowelScreen and symptomatic colonoscopy services at Wexford General Hospital (WGH). The patient safety incident relates to the work of a Consultant Endoscopist (referred to as Clinician Y) employed by WGH who undertook screening colonoscopies on behalf of the BowelScreen Programme since the commencement of the screening programme in WGH in March 2013. Clinician Y also performed non-screening colonoscopies for the diagnosis of symptomatic patients as part of routine surgical service provision at WGH.\\r\

  15. Evidence-based investigation of the influence of computer-aided detection of polyps on screening of colon cancer with CT colonography

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki

    2008-01-01

    Computed tomographic colonography (CTC), also known as virtual colonoscopy, is a CT examination of the colon for colorectal neoplasms. Recent large-scale clinical trials have demonstrated that CTC yields sensitivity comparable to optical colonoscopy in the detection of clinically significant polyps in a screening population, making CTC a promising technique for screening of colon cancer. For CTC to be a clinically practical means of screening, it must reliably and consistently detect polyps with high accuracy. However, high-level expertise is required to interpret the resulting CT images to find polyps, resulting in variable diagnostic accuracy among radiologists in the detection of polyps. A key technology to overcome this problem and to bring CTC to prime time for screening of colorectal cancer is computer-aided detection (CAD) of polyps. CAD automatically detects the locations of suspicious polyps in CTC images and presents them to radiologists. CAD has the potential to increase diagnostic performance in the detection of polyps as well as to reduce variability of the diagnostic accuracy among radiologists. This paper presents an evidence-based investigation of the influence of CAD on screening of colon cancer with CTC by describing the benefits of using CAD in the diagnosis of CTC, the fundamental CAD scheme for the detection of polyps in CTC, its detection performance, the effect on the improvement of detection performance, as well as the current and future challenges in CAD. (author)

  16. Superiority of split dose midazolam as conscious sedation for outpatient colonoscopy.

    Science.gov (United States)

    Lee, Hyuk; Kim, Jeong Hwan

    2009-08-14

    To elucidate the efficacy and safety of a split dose of midazolam in combination with meperidine for colonoscopy. Eighty subjects undergoing outpatient colonoscopy were randomly assigned to group A or B. Group A (n = 40) received a split dose of midazolam in combination with meperidine. Group B (n = 40) received a single dose of midazolam in combination with meperidine. Outcome measurements were level of sedation, duration of sedation and recovery, degree of pain and satisfaction, procedure-related memory, controllability, and adverse events. Group A had a lower frequency of significant hypoxemia (P = 0.043) and a higher sedation score on withdrawal of the endoscope from the descending colon than group B (P = 0.043). Group B recovered from sedation slightly sooner than group A (P memory, except insertion-related memory, were lower in group A one week after colonoscopic examination (P = 0.018 and P sedation status during colonoscopic examination and a reduction in procedure-related pain and memory, but resulted in longer recovery time.

  17. Fecal Molecular Markers for Colorectal Cancer Screening

    Directory of Open Access Journals (Sweden)

    Rani Kanthan

    2012-01-01

    Full Text Available Despite multiple screening techniques, including colonoscopy, flexible sigmoidoscopy, radiological imaging, and fecal occult blood testing, colorectal cancer remains a leading cause of death. As these techniques improve, their sensitivity to detect malignant lesions is increasing; however, detection of precursor lesions remains problematic and has generated a lack of general acceptance for their widespread usage. Early detection by an accurate, noninvasive, cost-effective, simple-to-use screening technique is central to decreasing the incidence and mortality of this disease. Recent advances in the development of molecular markers in faecal specimens are encouraging for its use as a screening tool. Genetic mutations and epigenetic alterations that result from the carcinogenetic process can be detected by coprocytobiology in the colonocytes exfoliated from the lesion into the fecal matter. These markers have shown promising sensitivity and specificity in the detection of both malignant and premalignant lesions and are gaining popularity as a noninvasive technique that is representative of the entire colon. In this paper, we summarize the genetic and epigenetic fecal molecular markers that have been identified as potential targets in the screening of colorectal cancer.

  18. Physical model of dimensional regularization

    Energy Technology Data Exchange (ETDEWEB)

    Schonfeld, Jonathan F.

    2016-12-15

    We explicitly construct fractals of dimension 4-ε on which dimensional regularization approximates scalar-field-only quantum-field theory amplitudes. The construction does not require fractals to be Lorentz-invariant in any sense, and we argue that there probably is no Lorentz-invariant fractal of dimension greater than 2. We derive dimensional regularization's power-law screening first for fractals obtained by removing voids from 3-dimensional Euclidean space. The derivation applies techniques from elementary dielectric theory. Surprisingly, fractal geometry by itself does not guarantee the appropriate power-law behavior; boundary conditions at fractal voids also play an important role. We then extend the derivation to 4-dimensional Minkowski space. We comment on generalization to non-scalar fields, and speculate about implications for quantum gravity. (orig.)

  19. Appointment waiting times and education level influence the quality of bowel preparation in adult patients undergoing colonoscopy

    Directory of Open Access Journals (Sweden)

    Goh Khean-Lee

    2011-07-01

    Full Text Available Abstract Background Risk factors for poor bowel preparation are recognized to be independent of the type of bowel preparation method used. Patient and administrative factors influencing bowel preparation are known to vary in different healthcare systems. Methods A prospective, cross-sectional study of patients undergoing colonoscopy in an Asian tertiary centre was conducted to identify risk factors associated with poor bowel preparation, and to evaluate the impact of poor bowel preparation on technical performance and patient comfort. Results Data on 501 patients (mean age 60.1 ± 14.0 years old, 51.2% males, 60.9% with secondary education or higher was available for analysis. Poor bowel preparation was present in 151 patients (30.1%. Lower education level (OR = 2.35, 95% CI = 1.54 - 3.60, colonoscopy appointment waiting time beyond 16 weeks (OR = 1.86, 95% CI = 1.04 - 3.37 and non-adherence to bowel preparation instructions (OR = 4.76, 95% CI = 3.00 - 7.55 were identified as independent risk factors for poor bowel preparation. Poor bowel preparation was associated with a lower cecal intubation rate (78.1% versus 98.3%, p Conclusions Education levels and appointment waiting times, in addition to non-adherence to bowel preparation instructions, increase the risk of poor bowel preparation in adult patients undergoing colonoscopy. The latter has a significant impact on colonoscopy performance and patient comfort.

  20. Effect of music on level of anxiety in patients undergoing colonoscopy without sedation.

    Science.gov (United States)

    Ko, Chia-Hui; Chen, Yi-Yu; Wu, Kuan-Ta; Wang, Shu-Chi; Yang, Jeng-Fu; Lin, Yu-Yin; Lin, Chia-I; Kuo, Hsiang-Ju; Dai, Chia-Yen; Hsieh, Meng-Hsuan

    2017-03-01

    Listening to music can be a noninvasive method for reducing the anxiety level without any adverse effects. The aim of this study was to explore whether music can reduce anxiety and to compare two different styles of music, informal classical music and light music, to ascertain the more effective style of music in reducing anxiety in patients undergoing colonoscopy without sedation. This study enrolled 138 patients who underwent colonoscopy without sedation during a general health examination from February 2009 to January 2015. The patients were randomly assigned to a group that did not listen to music, a group that listened to music by David Tolley, or a group that listened to music by Kevin Kern. The State-Trait Anxiety Inventory was used to evaluate the status of anxiety. A trend test for mild anxiety was performed on the patients in the three groups, and a significant trend was noted (p=0.017 for all patients; p=0.014 for analysis by sex). Multivariate analysis for mild anxiety on the patients in each group was also performed in this study, and music by Kevin Kern was found to have the lowest odds ratio (Odds ratio=0.34, p=0.045). Listening to music, especially music by Kevin Kern, reduced the level of anxiety in patients undergoing colonoscopy examination without sedation. Copyright © 2016. Published by Elsevier Taiwan LLC.

  1. Long-term evaluation of benefits, harms, and cost-effectiveness of the National Bowel Cancer Screening Program in Australia: a modelling study.

    Science.gov (United States)

    Lew, Jie-Bin; St John, D James B; Xu, Xiang-Ming; Greuter, Marjolein J E; Caruana, Michael; Cenin, Dayna R; He, Emily; Saville, Marion; Grogan, Paul; Coupé, Veerle M H; Canfell, Karen

    2017-07-01

    No assessment of the National Bowel Screening Program (NBCSP) in Australia, which considers all downstream benefits, costs, and harms, has been done. We aimed to use a comprehensive natural history model and the most recent information about cancer treatment costs to estimate long-term benefits, costs, and harms of the NBCSP (2 yearly immunochemical faecal occult blood testing screening at age 50-74 years) and evaluate the incremental effect of improved screening participation under different scenarios. In this modelling study, a microsimulation model, Policy1-Bowel, which simulates the development of colorectal cancer via both the conventional adenoma-carcinoma and serrated pathways was used to simulate the NBCSP in 2006-40, taking into account the gradual rollout of NBCSP in 2006-20. The base-case scenario assumed 40% screening participation (currently observed behaviour) and two alternative scenarios assuming 50% and 60% participation by 2020 were modelled. Aggregate year-by-year screening, diagnosis, treatment and surveillance-related costs, resource utilisation (number of screening tests and colonoscopies), and health outcomes (incident colorectal cancer cases and colorectal cancer deaths) were estimated, as was the cost-effectiveness of the NBCSP. With current levels of participation (40%), the NBCSP is expected to prevent 92 200 cancer cases and 59 000 deaths over the period 2015-40; an additional 24 300 and 37 300 cases and 16 800 and 24 800 deaths would be prevented if participation was increased to 50% and 60%, respectively. In 2020, an estimated 101 000 programme-related colonoscopies will be done, associated with about 270 adverse events; an additional 32 500 and 49 800 colonoscopies and 88 and 134 adverse events would occur if participation was increased to 50% and 60%, respectively. The overall number needed to screen (NNS) is 647-788 per death prevented, with 52-59 colonoscopies per death prevented. The programme is cost

  2. Causes of lower gastrointestinal bleeding on colonoscopy

    International Nuclear Information System (INIS)

    Rehman, A.U.; Gul, R.; Khursheed, L.; Hadayat, R.

    2017-01-01

    Background: Bleeding from anus is usually referred as rectal bleeding but actually rectal bleeding is defined as bleeding from lower colon or rectum, which means bleeding from a place distal to ligament of Treitz. This study was conducted to determine the frequency of different causes of rectal bleeding in patients at Ayub Teaching Hospital, Abbottabad. Methods: One hundred and seventy-five patients with evidence of rectal bleed, without gender discrimination were selected by non-probability convenient sampling from the out-patient department and general medical wards. Patients with suspected upper GI source of bleeding; acute infectious bloody diarrhoea and any coagulopathy were excluded from the study. All patients were subjected to fibre optic colonoscopy after preparation of the gut and findings were recorded. Where necessary, biopsy samples were also taken. Diagnosis was based on colonoscopic findings. Results: A total of 175 patients (92 males and 83 females) with mean age 35.81±9.18 years were part of the study. Colonoscopy showed abnormal findings in 150 (85.7%) patients. The commonest diagnosis was haemorrhoids, which was found in 39 (22.3%) patients. It was followed by inflammatory bowel disease (IBD) in 30 (17.1%) patients, solitary rectal ulcer in 13 (7.4%) patients and polyps in 25 (14.3%) patients. Other less frequent findings were non-specific inflammation and fungating growths in rectum. Conclusion: Haemorrhoids was the leading cause of bleeding per rectum in this study, followed by evidence of IBD while infrequent findings of polyps and diverticuli indicate that these are uncommon in this region. (author)

  3. Simulation-Based Training of Non-Technical Skills in Colonoscopy: Protocol for a Randomized Controlled Trial.

    Science.gov (United States)

    Khan, Rishad; Scaffidi, Michael A; Walsh, Catharine M; Lin, Peter; Al-Mazroui, Ahmed; Chana, Barinder; Kalaichandran, Ruben; Lee, Woojin; Grantcharov, Teodor P; Grover, Samir C

    2017-08-04

    Non-technical skills (NTS), such as communication and professionalism, contribute to the safe and effective completion of procedures. NTS training has previously been shown to improve surgical performance. Moreover, increases in NTS have been associated with improved clinical endoscopic performance. Despite this evidence, NTS training has not been tested as an intervention in endoscopy. The aim of this study is to evaluate the effectiveness of a simulation-based training (SBT) curriculum of NTS on novice endoscopists' performance of clinical colonoscopy. Novice endoscopists were randomized to 2 groups. The control group received 4 hours of interactive didactic sessions on colonoscopy theory and 6 hours of SBT. Hours 5 and 6 of the SBT were integrated scenarios, wherein participants interacted with a standardized patient and nurse, while performing a colonoscopy on the virtual reality (VR) simulator. The NTS (intervention) group received the same teaching sessions but the last hour was focused on NTS teaching. The NTS group also reviewed a checklist of tasks relevant to NTS concepts prior to each integrated scenario case and was provided with dedicated feedback on their NTS performance during the integrated scenario practice. All participants were assessed at baseline, immediately after training, and 4 to 6 weeks post-training. The primary outcome measure is colonoscopy-specific performance in the clinical setting. In total, 42 novice endoscopists completed the study. Data collection and analysis is ongoing. We anticipate completion of all assessments by August 2017. Data analysis, manuscript writing, and subsequent submission for publication is expected to be completed by December 2017. Results from this study may inform the implementation of NTS training into postgraduate gastrointestinal curricula. NTS curricula may improve attitudes towards patient safety and self-reflection among trainees. Moreover, enhanced NTS may lead to superior clinical performance and

  4. Clinical usefulness of single-balloon endoscopy in patients with previously incomplete colonoscopy

    Science.gov (United States)

    Kobayashi, Kiyonori; Mukae, Miyuki; Ogawa, Taishi; Yokoyama, Kaoru; Sada, Miwa; Koizumi, Wasaburo

    2013-01-01

    AIM: To evaluate the clinical usefulness of single-balloon endoscopy (SBE) in patients in whom a colonoscope was technically difficult to insert previously. METHODS: The study group comprised 15 patients (8 men and 7 women) who underwent SBE for colonoscopy (30 sessions). The number of SBE sessions was 1 in 7 patients, 2 in 5 patients, 3 in 1 patient, 4 in 1 patient, and 6 in 1 patient. In all patients, total colonoscopy was previously unsuccessful. The reasons for difficulty in scope passage were an elongated colon in 6 patients, severe intestinal adhesions after open surgery in 4, an elongated colon and severe intestinal adhesions in 2, a left inguinal hernia in 2, and multiple diverticulosis of the sigmoid colon in 1. Three endoscopists were responsible for SBE. The technique for inserting SBE in the colon was basically similar to that in the small intestine. The effectiveness of SBE was assessed on the basis of the success rate of total colonoscopy and the presence or absence of complications. We also evaluated the diagnostic and treatment outcomes of colonoscopic examinations with SBE. RESULTS: Total colonoscopy was successfully accomplished in all sessions. The mean insertion time to the cecum was 22.9 ± 8.9 min (range 9 to 40). Abnormalities were found during 21 sessions of SBE. The most common abnormality was colorectal polyps (20 sessions), followed by radiation colitis (3 sessions) and diverticular disease of the colon (3 sessions). Colorectal polyps were resected endoscopically in 15 sessions. A total of 42 polyps were resected endoscopically, using snare polypectomy in 32 lesions, hot biopsy in 7 lesions, and endoscopic mucosal resection in 3 lesions. Fifty-six colorectal polyps were newly diagnosed on colonoscopic examination with SBE. Histopathologically, these lesions included 2 intramucosal cancers, 42 tubular adenomas, and 2 tubulovillous adenomas. The mean examination time was 48.2 ± 20.0 min (range 25 to 90). Colonoscopic examination or

  5. Improving the quality of colonoscopy bowel preparation using a smart phone application: a randomized trial.

    Science.gov (United States)

    Lorenzo-Zúñiga, Vicente; Moreno de Vega, Vicente; Marín, Ingrid; Barberá, Marta; Boix, Jaume

    2015-07-01

    Getting ready for a colonoscopy is difficult and involves many steps. Information given to patients is very important for adherence to treatment. We created a novel smart phone application (SPA) aimed to increase bowel preparation quality and patient satisfaction. We carried out a prospective, endoscopist-blinded, randomized, controlled trial. We enrolled 260 outpatient (58% female, age range 21-75 years) owners of a smartphone. Patients were allocated to two different protocols: instructions provided by SPA (SPA group; n = 108) or written instructions with visual aids (control group; n = 152). All procedures were carried out in the afternoon and patients received the same purgative regimen (2 L polyethylene glycol (PEG) solution plus ascorbic acid), in a full-dose same-day regimen. The study was designed to detect an improvement in quality of bowel preparation using the Harefield Cleansing Scale (HCS) scale. Effect of protocol on patient satisfaction was assessed with a specific questionnaire at the time of colonoscopy. Proportion of patients who obtained successful bowel preparation for colonoscopy (HCS A or B) was significantly higher in the SPA group than in the control group (100% vs 96.1%, respectively; P = 0.037). Mean global HCS scores were similar in both groups. Patient-reported tolerability and overall experience with the prescribed bowel preparation were significantly higher for the SPA group than for the control group. Successful cleansing and patient acceptability with the use of SPA were superior to written instructions in outpatients submitted for colonoscopy using 2 L PEG solution plus ascorbic acid. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  6. Medicare Under Age 65 and Medicaid Patients Have Poorer Bowel Preparations: Implications for Recommendations for an Early Repeat Colonoscopy.

    Directory of Open Access Journals (Sweden)

    Bryan B Brimhall

    Full Text Available Colonoscopy is performed on patients across a broad spectrum of demographic characteristics. These characteristics may aggregate by patient insurance provider and influence bowel preparation quality and the prevalence of adenomas. The purpose of this study was to evaluate the association of insurance status and suboptimal bowel preparation, recommendation for an early repeat colonoscopy due to suboptimal bowel preparation, adenoma detection rate (ADR, and advanced ADR (AADR.This is a cohort study of outpatient colonoscopies (n = 3113 at a single academic medical center. Patient insurance status was categorized into five groups: 1 Medicare < 65y; 2 Medicare ≥ 65y; 3 Tricare/VA; 4 Medicaid/Colorado Indigent Care Program (CICP; and 5 commercial insurance. We used multivariable logistic or linear regression modeling to estimate the risks for the association between patient insurance and suboptimal bowel preparation, recommendation for an early repeat colonoscopy due to suboptimal bowel preparation, ADR, and AADR. Models were adjusted for appropriate covariates.Medicare patients < 65y (OR 4.91; 95% CI: 3.25-7.43 and Medicaid/CICP patients (OR 4.23; 95% CI: 2.65-7.65 were more likely to have a suboptimal preparation compared to commercial insurance patients. Medicare patients < 65y (OR 5.58; 95% CI: 2.85-10.92 and Medicaid/CICP patients (OR 3.64; CI: 1.60-8.28 were more likely to receive a recommendation for an early repeat colonoscopy compared to commercial insurance patients. Medicare patients < 65y had a significantly higher adjusted ADR (OR 1.50; 95% CI: 1.03-2.18 and adjusted AADR (OR 1.99; 95% CI: 1.15-3.44 compared to commercial insurance patients.Understanding the reasons for the higher rate of a suboptimal bowel preparation in Medicare < 65y and Medicaid/CICP patients and reducing this rate is critical to improving colonoscopy outcomes and reducing healthcare costs in these populations.

  7. Bibliographic review, indication guidelines of colonoscopy and its application in Costa Rica; Revision bibliografica, guias de indicacion de colonoscopia y su aplicacion en Costa Rica

    Energy Technology Data Exchange (ETDEWEB)

    Vargas Perez, Carmen

    2013-07-01

    A review of the available evidence is realized at around the appropriate indications and quality criteria in colonoscopy. This review has served as instrument to programs of early detection, diagnostic and treatment of colonic diseases in endoscopy units and endoscopists that have effected colonoscopy. Colorectal cancer (CRC) has been a preventable disease based on the effects of manipulable risk factors and screening for early detection of the same. Family history, older age, male sex, the number of size of adenomas, the presence of a villous component, high grade dysplasia and proximal location are associated with a significantly increased of the risk for CRC. Inappropriate/unnecessary indication of the procedure and lack of criteria uniformity, ignoring the international clinical guidelines of colonoscopy indication, has caused a collapse of endoscopy units in the world to the prejudice of the quality. Applicable quality indicators are defined to establish locally based on the available evidence, the minimum requirements that must meet endoscopy units and endoscopists that have participated in CRC screening programs. A preferred strategy or protocol of indication and monitoring is proposed to contemplate the evaluable quality criteria. Quality indicators of colonoscopy have allowed to optimize resources and determine the variability of the compliance between hospitals, endoscopy units or endoscopists and to identify deficiencies to plan improvement strategies. The medical criteria adequately base and individualized has prevailed in the diagnostic strategy decision. A constant evaluation of the performance in endoscopy units should be developed according to criteria of international quality. The protocolization and uniformity of criteria and concepts of the reference system for colonoscopy and post realization report, have been the key to adequate communication between health professionals and the patient. Alternative and complementary studies have been part of

  8. Splenic rupture after colonoscopy: Report of a case and review of literature

    Directory of Open Access Journals (Sweden)

    Piccolo Gaetano

    2008-02-01

    Full Text Available Abstract Splenic rupture is a rare complication of colonoscopy. For this reason the diagnosis could be delayed and the outcome dismal. Fifty-four cases of splenic rupture after colonoscopy have been described in the literature. The majority of the cases required emergent or delayed splenectomy, 13 of these cases were treated conservatively. The main feature that stands out from the review of the literature is the "surprise" of this unexpected complication. This factor explains the elevated mortality (2 out of 54 cases, likely due to the delay in diagnosis. The case here described is probably among the most complex published in the literature; in fact the presence of dense intra-abdominal adhesions not only contributed to the complication itself, but also explain the confinement of the hemoperitoneum to the left supra-mesocolic space and the delayed presentation (13 days from the time of the trauma.

  9. Primary care practice organization influences colorectal cancer screening performance.

    Science.gov (United States)

    Yano, Elizabeth M; Soban, Lynn M; Parkerton, Patricia H; Etzioni, David A

    2007-06-01

    To identify primary care practice characteristics associated with colorectal cancer (CRC) screening performance, controlling for patient-level factors. Primary care director survey (1999-2000) of 155 VA primary care clinics linked with 38,818 eligible patients' sociodemographics, utilization, and CRC screening experience using centralized administrative and chart-review data (2001). Practices were characterized by degrees of centralization (e.g., authority over operations, staffing, outside-practice influence); resources (e.g., sufficiency of nonphysician staffing, space, clinical support arrangements); and complexity (e.g., facility size, academic status, managed care penetration), adjusting for patient-level covariates and contextual factors. Chart-based evidence of CRC screening through direct colonoscopy, sigmoidoscopy, or consecutive fecal occult blood tests, eliminating cases with documented histories of CRC, polyps, or inflammatory bowel disease. After adjusting for sociodemographic characteristics and health care utilization, patients were significantly more likely to be screened for CRC if their primary care practices had greater autonomy over the internal structure of care delivery (pmanagement and referral procedures are associated with significantly lower CRC screening performance. Competition with hospital resource demands may impinge on the degree of internal organization of their affiliated primary care practices.

  10. Virtual colonoscopy training and accreditation: a national survey of radiologist experience and attitudes in the UK

    International Nuclear Information System (INIS)

    Burling, D.; Moore, A.; Taylor, S.; La Porte, S.; Marshall, M.

    2007-01-01

    Aim: Expert consensus recommends directed training and possibly in the future, formal accreditation before independent virtual colonoscopy (VC) reporting. We surveyed radiologists' experience of VC training, compared with barium enema, and assessed attitudes towards accreditation. Materials and methods: A questionnaire was sent to 78 consultant radiologists from 72 centres (65 National Health Service hospitals; seven independent primary screening centres) offering a VC service. Results: Fifty-four (69%) eligible radiologists responded. They had interpreted 18,152 examinations (range 3-1500) in total versus 232,350 (13 times more) barium enemas. Twenty-two (41%) deemed their VC training as inadequate [including five (45%) of screening centre radiologists], and only 14 (26%) had attended a training workshop due to lack of availability (54%) or financial/study leave constraints (24%). Eleven (20%) radiologists routinely double-reported VC examinations versus 37 (69%) barium enemas, yet 21 (39%) considered requirements for VC training were greater than barium enema. Thirty-eight (70%) favoured accreditation beyond internal audit for VC versus 15(28%) for barium enema. Of these 38, seven (18%) favoured 'one-off,' and 18 (47%) periodic testing, with 16 (42%) favouring external audit alone or in combination with testing. Overall, 42 (78%) considered specific accreditation for reporting screening examinations appropriate and 45 (83%) respondents preferred a national radiological organization to regulate such a scheme. Conclusion: There is wide variability in reporting experience and recommendations for VC training have not been widely adopted, in part due to limited access to dedicated workshops. UK radiologists are generally in favour of VC accreditation, governed by a national radiology organization

  11. Multilevel predictors of colorectal cancer testing modality among publicly and privately insured people turning 50.

    Science.gov (United States)

    Wheeler, Stephanie B; Kuo, Tzy-Mey; Meyer, Anne Marie; Martens, Christa E; Hassmiller Lich, Kristen M; Tangka, Florence K L; Richardson, Lisa C; Hall, Ingrid J; Smith, Judith Lee; Mayorga, Maria E; Brown, Paul; Crutchfield, Trisha M; Pignone, Michael P

    2017-06-01

    Understanding multilevel predictors of colorectal cancer (CRC) screening test modality can help inform screening program design and implementation. We used North Carolina Medicare, Medicaid, and private, commercially available, health plan insurance claims data from 2003 to 2008 to ascertain CRC test modality among people who received CRC screening around their 50th birthday, when guidelines recommend that screening should commence for normal risk individuals. We ascertained receipt of colonoscopy, fecal occult blood test (FOBT) and fecal immunochemical test (FIT) from billing codes. Person-level and county-level contextual variables were included in multilevel random intercepts models to understand predictors of CRC test modality, stratified by insurance type. Of 12,570 publicly-insured persons turning 50 during the study period who received CRC testing, 57% received colonoscopy, whereas 43% received FOBT/FIT, with significant regional variation. In multivariable models, females with public insurance had lower odds of colonoscopy than males (odds ratio [OR] = 0.68; p testing, 42% received colonoscopy, whereas 58% received FOBT/FIT, with significant regional variation. In multivariable models, females with private insurance had lower odds of colonoscopy than males (OR = 0.43; p < 0.05). People living 10-15 miles away from endoscopy facilities also had lower odds of colonoscopy than those living within 5 miles (OR = 0.91; p < 0.05). Both colonoscopy and FOBT/FIT are widely used in North Carolina among insured persons newly age-eligible for screening. The high level of FOBT/FIT use among privately insured persons and women suggests that renewed emphasis on FOBT/FIT as a viable screening alternative to colonoscopy may be important.

  12. Exploring access and attitudes to regular sexually transmitted infection screening: the views of young, multi-ethnic, inner-city, female students.

    Science.gov (United States)

    Normansell, Rebecca; Drennan, Vari M; Oakeshott, Pippa

    2016-04-01

    Low uptake of sexually transmitted infection (STI) testing by young people is a major public health problem worldwide. The aims of this qualitative, community-based study were to explore access and attitudes to STI screening in high risk, young, ethnically diverse female students. Qualitative semi-structured interviews were conducted at an inner-London further education college with 17 women aged 16-25 years. The women wanted convenient, regular STI testing and perceived this as responsible behaviour. However, they doubted the maturity of their peers who were unlikely to view themselves as candidates for testing, and feared the perceived stigma associated with testing. This was reflected in their preference for confidential testing. Despite attending their general practice for non-sexual health matters, most did not consider this option for STI testing. However, the long wait in specialist clinics was an important barrier. Many younger participants would not want postal STI sample kits sent to their homes. We found dissatisfaction with sexual health education. STI screening for underserved groups such as young sexually active ethnically diverse female college students needs to be confidential, convenient, easily accessed and offered in ways that allow them to consider themselves as candidates for such screening without fear of social stigma. Family doctors should be aware that young women often do not perceive primary care to be an option for accessing STI screening, and could consider ways of advertising these services. Policymakers and commissioners should be aware that clinic waiting times and lack of education remain barriers to testing. © 2015 John Wiley & Sons Ltd.

  13. [THE FAILURE MODES AND EFFECTS ANALYSIS FACILITATES A SAFE, TIME AND MONEY SAVING OPEN ACCESS COLONOSCOPY SERVICE].

    Science.gov (United States)

    Gingold-Belfer, Rachel; Niv, Yaron; Horev, Nehama; Gross, Shuli; Sahar, Nadav; Dickman, Ram

    2017-04-01

    Failure modes and effects analysis (FMEA) is used for the identification of potential risks in health care processes. We used a specific FMEA - based form for direct referral for colonoscopy and assessed it for procedurerelated perforations. Ten experts in endoscopy evaluated and computed the entire referral process, modes of preparation for the endoscopic procedure, the endoscopic procedure itself and the discharge process. We used FMEA assessing for likelihood of occurrence, detection and severity and calculated the risk profile number (RPN) for each of the above points. According to the highest RPN results we designed a specific open access referral form and then compared the occurrence of colonic perforations (between 2010 and 2013) in patients who were referred through the open access arm (Group 1) to those who had a prior clinical consultation (non-open access, Group 2). Our experts in endoscopy (5 physicians and 5 nurses) identified 3 categories of failure modes that, on average, reached the highest RPNs. We identified 9,558 colonoscopies in group 1, and 12,567 in group 2. Perforations were identified in three patients from the open access group (1:3186, 0.03%) and in 10 from group 2 (1:1256, 0.07%) (p = 0.024). Direct referral for colonoscopy saved 9,558 pre-procedure consultations and the sum of $850,000. The FMEA tool-based specific referral form facilitates a safe, time and money saving open access colonoscopy service. Our form may be adopted by other gastroenterological clinics in Israel.

  14. An evaluation of four rare-earth film-screen combinations

    International Nuclear Information System (INIS)

    Nettle, J.R.L.; Ritchings, R.T.

    1980-01-01

    Objective and subjective assessments were made on four film-screen combinations at 140 kV for use on an EMI body scanner. The combinations used were: 3M XD film + Trimax Alpha 8 screens; Agfa Gevaert RP film + MR600 screens; Kodak Ortho G film + Lanex regular screens and Ilford type S film + rare earth rapid R screens. The objective assessment is based on the optical density of the image of a test object on a radiograph. Receiver operating characteristic techniques are used in the subjective assessment. The best results in each assessment were obtained using the Kodak Ortho G film + Lanex regular screens. (author)

  15. Colorectal Cancer Screening: What Is the Population's Opinion

    Directory of Open Access Journals (Sweden)

    Cristina Teixeira

    2017-10-01

    Full Text Available Background: Colorectal cancer (CRC is the first cause of death by cancer in Portugal and mortality has been increasing in the last 30 years. Materials and Methods: During a raising awareness campaign performed by our Gastroenterology Department, in Setúbal, Portugal, an anonymous written questionnaire was developed and presented in order to evaluate the population's knowledge and attitude regarding CRC screening. Results: The following results were reported: 140 persons; mean age 54.6 years; 61.4% women; 22.1% had a family history of colorectal cancer. The main risk factors mentioned by the respondents were family history of CRC, previous history of intestinal polyps, and intestinal infection. Screening was considered useful by all respondents. About 60% of the respondents had been counselled, at least, on one screening technique, mainly by their general practitioner: colonoscopy in 31, fecal occult blood test in 44, and flexible sigmoidoscopy in 9. Most of the respondents had had the appropriate screening test, according to their age and family history. Fourteen of the respondents had not undergone the recommended screening. Their answers showed that this was due to fear of pain/discovering a disease as well as embarrassment. Conclusion: Although the majority of the respondents were aware of the importance of CRC screening, results show that there are still several misconceptions about risk factors, fear, and reluctance concerning the screening techniques. Awareness actions are useful to clarify possible questions and inform the population in order to increase compliance with screening.

  16. Revaluation on detection of metastatic cancer of the colorectum with barium enema. Comparison with computed tomography and colonoscopy

    International Nuclear Information System (INIS)

    Watari, Jiro; Mizukami, Yusuke; Tanabe, Hirotaka

    1996-01-01

    The findings with barium enema were analyzed and compared to those with computed tomography and colonoscopy in 15 patients with metastatic cancer of the colorectum, which were from 8 gastric, 2 colonic, 2 ovarian, 1 pancreatic, 1 prostatic carcinomas and 1 unknown origin. Primary cancers of intra-abdominal cavity origin tended to make multiple colorectal metastases (91.7%). With barium enema colonic and rectal involvement was mostly expressed as the tethered type and the diffuse type by Ishikawa's classification, respectively. Computed tomography detected direct tumor invasion to the colorectum in 4 cases. Of the other 11 cases, 8 patients (72.3%) showed abnormally thickened colorectal wall. Colonoscopy detected only 3 (37.5%) out of 8 lesions seen in 4 patients who had undergone colonoscopy before barium enema. Many of the lesions missed were the tethered type involvement. Barium enema is the most sensitive method to detect metastatic cancer of the colorectum. (author)

  17. Dimensions of religiousness and cancer screening behaviors among church-going Latinas.

    Science.gov (United States)

    Allen, Jennifer D; Pérez, John E; Pischke, Claudia R; Tom, Laura S; Juarez, Alan; Ospino, Hosffman; Gonzalez-Suarez, Elizabeth

    2014-02-01

    Churches are a promising setting through which to reach Latinas with cancer control efforts. A better understanding of the dimensions of religiousness that impact health behaviors could inform efforts to tailor cancer control programs for this setting. The purpose of this study was to explore relationships between dimensions of religiousness with adherence to cancer screening recommendations among church-going Latinas. Female Spanish-speaking members, aged 18 and older from a Baptist church in Boston, Massachusetts (N = 78), were interviewed about cancer screening behaviors and dimensions of religiousness. We examined adherence to individual cancer screening tests (mammography, Pap test, and colonoscopy), as well as adherence to all screening tests for which participants were age-eligible. Dimensions of religiousness assessed included church participation, religious support, active and passive spiritual health locus of control, and positive and negative religious coping. Results showed that roughly half (46 %) of the sample had not received all of the cancer screening tests for which they were age-eligible. In multivariate analyses, positive religious coping was significantly associated with adherence to all age-appropriate screening (OR = 5.30, p religious coping could increase the impact of cancer control interventions for Latinas.

  18. The attitudes of primary care providers towards screening for colorectal cancer

    Directory of Open Access Journals (Sweden)

    Jesús López-Torres Hidalgo

    2013-06-01

    Full Text Available Background and objective: the scientific community supports the appropriateness of colorectal cancer screening, and there is consensus on the need to raise awareness about the significance of prevention among both health care professionals and the population. The goal was to record the attitude of primary care providers towards colorectal cancer screening, as well as the main barriers to both patient and provider participation. Methods: a cross-sectional, observational study was performed of 511 professionals in Albacete Health District. Variables included views on screening effectiveness and cost-effectiveness, acceptance by providers and patients, barriers to participation, frequency of prevention recommendations, and education needs. Results: most (76 % considered screening was effective; 85 % said acceptance of fecal occult blood testing was intermediate or high, and 68.2 % this is also the case for colonoscopy when needed; 71.9 % would recommend screening should a population-based program be implemented (currently only 9.7 % recommends this. Correspondence analysis revealed that recommendation is more common when assigned populations are smaller. Conclusions: most providers consider screening is both effective and acceptable for patients. In today's situation, where screening is only performed in an opportunistic manner, the proportion of professionals who commonly recommend screening for the mid-risk population is low, especially when assigned populations are huge.

  19. Effective colonoscopy training techniques: strategies to improve patient outcomes

    Directory of Open Access Journals (Sweden)

    Papanikolaou IS

    2016-03-01

    Full Text Available Ioannis S Papanikolaou,1 Pantelis S Karatzas,2 Lazaros T Varytimiadis,2 Athanasios Tsigaridas,2 Michail Galanopoulos,2 Nikos Viazis,2 Dimitrios G Karamanolis21Hepato-gastroenterology Unit, 2nd Department of Internal Medicine, Attikon University General Hospital, University of Athens, 2Gastroenterology Department, Evangelismos Hospital, Athens, GreeceAbstract: Colonoscopy has substantially evolved during the last 20 years and many different training techniques have been developed in order to improve the performance of endoscopists. The most known are mechanical simulators, virtual reality simulators, computer-simulating endoscopy, magnetic endoscopic imaging, and composite and explanted animal organ simulators. Current literature generally indicates that the use of simulators improves performance of endoscopists and enhances safety of patients, especially during the initial phase of training. Moreover, newer endoscopes and imaging techniques such as high-definition colonoscopes, chromocolonoscopy with dyes spraying, and third-eye retroscope have been incorporated in everyday practice, offering better visualization of the colon and detection of polyps. Despite the abundance of these different technological features, training devices are not widely used and no official guideline or specified training algorithm or technique for lower gastrointestinal endoscopy has been evolved. In this review, we present the most important training methods currently available and evaluate these using existing literature. We also try to propose a training algorithm for novice endoscopists.Keywords: endoscopy, colonoscopy, teaching techniques, simulator, endoscopists, colon, polyps

  20. Real-Time Monitoring of Results During First Year of Dutch Colorectal Cancer Screening Program and Optimization by Altering Fecal Immunochemical Test Cut-Off Levels.

    Science.gov (United States)

    Toes-Zoutendijk, Esther; van Leerdam, Monique E; Dekker, Evelien; van Hees, Frank; Penning, Corine; Nagtegaal, Iris; van der Meulen, Miriam P; van Vuuren, Anneke J; Kuipers, Ernst J; Bonfrer, Johannes M G; Biermann, Katharina; Thomeer, Maarten G J; van Veldhuizen, Harriët; Kroep, Sonja; van Ballegooijen, Marjolein; Meijer, Gerrit A; de Koning, Harry J; Spaander, Manon C W; Lansdorp-Vogelaar, Iris

    2017-03-01

    After careful pilot studies and planning, the national screening program for colorectal cancer (CRC), with biennial fecal immunochemical tests (FITs), was initiated in The Netherlands in 2014. A national information system for real-time monitoring was developed to allow for timely evaluation. Data were collected from the first year of this screening program to determine the importance of planning and monitoring for optimal screening program performance. The national information system of the CRC screening program kept track of the number of invitations sent in 2014, FIT kits returned, and colonoscopies performed. Age-adjusted rates of participation, the number of positive test results, and positive predictive values (PPVs) for advanced neoplasia were determined weekly, quarterly, and yearly. In 2014, there were 741,914 persons invited for FIT; of these, 529,056 (71.3%; 95% CI, 71.2%-71.4%) participated. A few months into the program, real-time monitoring showed that rates of participation and positive test results (10.6%; 95% CI, 10.5%-10.8%) were higher than predicted and the PPV was lower (42.1%; 95% CI, 41.3%-42.9%) than predicted based on pilot studies. To reduce the burden of unnecessary colonoscopies and alleviate colonoscopy capacity, the cut-off level for a positive FIT result was increased from 15 to 47 μg Hb/g feces halfway through 2014. This adjustment decreased the percentage of positive test results to 6.7% (95% CI, 6.6%-6.8%) and increased the PPV to 49.1% (95% CI, 48.3%-49.9%). In total, the first year of the Dutch screening program resulted in the detection of 2483 cancers and 12,030 advanced adenomas. Close monitoring of the implementation of the Dutch national CRC screening program allowed for instant adjustment of the FIT cut-off levels to optimize program performance. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  1. Change of characteristic curves using light emission spectrum of the intensifying screens

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Kang, Hong Seok; Lee, In Ja; Huh, Joon

    1990-01-01

    This report is study about difference of H-D curve in regular film and ortho type film, and obtained results as follows: 1. In the blue-color emission intensifying screen, ortho type films and in the green-color emission intensifying screens, regular type are decreased in their gradient. 2. When joint use of regular type film and ortho type film, the gradient difference not seen in blue color screen. 3. The gradient difference seen clearly in G4, KM screens (green color emission intensifying). Especially, in part of high film density, the gradient difference are great. So we have to right use of screen and film because not matched used of there the sensitivity and gradient are decrease

  2. UNFOLDED REGULAR AND SEMI-REGULAR POLYHEDRA

    Directory of Open Access Journals (Sweden)

    IONIŢĂ Elena

    2015-06-01

    Full Text Available This paper proposes a presentation unfolding regular and semi-regular polyhedra. Regular polyhedra are convex polyhedra whose faces are regular and equal polygons, with the same number of sides, and whose polyhedral angles are also regular and equal. Semi-regular polyhedra are convex polyhedra with regular polygon faces, several types and equal solid angles of the same type. A net of a polyhedron is a collection of edges in the plane which are the unfolded edges of the solid. Modeling and unfolding Platonic and Arhimediene polyhedra will be using 3dsMAX program. This paper is intended as an example of descriptive geometry applications.

  3. Breast ultrasound tomography with total-variation regularization

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTIT.; Duric, Neb [KARMANOS CANCER INSTIT

    2009-01-01

    Breast ultrasound tomography is a rapidly developing imaging modality that has the potential to impact breast cancer screening and diagnosis. A new ultrasound breast imaging device (CURE) with a ring array of transducers has been designed and built at Karmanos Cancer Institute, which acquires both reflection and transmission ultrasound signals. To extract the sound-speed information from the breast data acquired by CURE, we have developed an iterative sound-speed image reconstruction algorithm for breast ultrasound transmission tomography based on total-variation (TV) minimization. We investigate applicability of the TV tomography algorithm using in vivo ultrasound breast data from 61 patients, and compare the results with those obtained using the Tikhonov regularization method. We demonstrate that, compared to the Tikhonov regularization scheme, the TV regularization method significantly improves image quality, resulting in sound-speed tomography images with sharp (preserved) edges of abnormalities and few artifacts.

  4. Can we ease the financial burden of colonoscopy? Using real-time endoscopic assessment of polyp histology to predict surveillance intervals.

    Science.gov (United States)

    Chandran, S; Parker, F; Lontos, S; Vaughan, R; Efthymiou, M

    2015-12-01

    Polyps identified at colonoscopy are predominantly diminutive (1%) of high-grade dysplasia or carcinoma; however, the cost of histological assessment is substantial. The aim of this study was to determine whether prediction of colonoscopy surveillance intervals based on real-time endoscopic assessment of polyp histology is accurate and cost effective. A prospective cohort study was conducted across a tertiary care and private community hospital. Ninety-four patients underwent colonoscopy and polypectomy of diminutive (≤5 mm) polyps from October 2012 to July 2013, yielding a total of 159 polyps. Polyps were examined and classified according to the Sano-Emura classification system. The endoscopic assessment (optical diagnosis) of polyp histology was used to predict appropriate colonoscopy surveillance intervals. The main outcome measure was the accuracy of optical diagnosis of diminutive colonic polyps against the gold standard of histological assessment. Optical diagnosis was correct in 105/108 (97.2%) adenomas. This yielded a sensitivity, specificity and positive and negative predictive values (with 95%CI) of 97.2% (92.1-99.4%), 78.4% (64.7-88.7%), 90.5% (83.7-95.2%) and 93% (80.9-98.5%) respectively. Ninety-two (98%) patients were correctly triaged to their repeat surveillance colonoscopy. Based on these findings, a cut and discard approach would have resulted in a saving of $319.77 per patient. Endoscopists within a tertiary care setting can accurately predict diminutive polyp histology and confer an appropriate surveillance interval with an associated financial benefit to the healthcare system. However, limitations to its application in the community setting exist, which may improve with further training and high-definition colonoscopes. © 2015 Royal Australasian College of Physicians.

  5. Colonoscopy quality assessment Valoración de la calidad en la práctica de la colonoscopia

    Directory of Open Access Journals (Sweden)

    S. Morán Sánchez

    2009-02-01

    Full Text Available Aim: colonoscopy has become accepted as the most effective method for colon exploration. Some application problems have been detected in the setting of normal clinical care due to its wide range of uses in recent years, and therefore there is a need to measure colonoscopy quality. For that purpose valid quality indicators are necessary to be defined. The application process of some quality indicators is presented in this study. The proposed indicators in this study are: quality of bowel preparation, cecal intubation rate, withdrawal time, adenoma detection rate, and adenoma removal rate. Material and method: this is a prospective 12-month study where colonoscopies performed in the VI health area of Murcia Region were evaluated. From February 2006 to February 2007 a total of 609 subjects were eligible for colonoscopy after a positive fecal blood test in the setting of a colorectal cancer screening program. A sample of thirty patients (n: 30 was considered representative to assess the reliability of quality indicators and for a preliminary analysis of results. Results: indicators results are: quality of bowel preparation (87%, kappa 0.74 (95% CI: 0.48-0.99; cecal intubation rate (90% 0.74 (95% CI: 0.49-0.99; adenoma detection and removal rate (96%, kappa: 0.78 (95% CI: 0.53-0.99; withdrawal time: 13.36 min (95% CI: 10.48-16.11. Kappa: 0.78 (95% CI: 0.49-0.99. Conclusions: quality indicators definition and application in colonoscopy performance is possible. More studies are necessary to define the role of these indicators in the setting of clinical practice.Objetivo: la colonoscopia constituye la técnica exploratoria del colon más importante en la actualidad. Su uso, cada vez más frecuente conlleva la aparición de problemas en su aplicación. Es necesario medir la calidad en la realización de esta técnica, para ello es preciso definir indicadores válidos que permitan la realización de ciclos de evaluación de la calidad. En este estudio se

  6. Bowel Preparation for Colonoscopy with Sodium Phosphate Solution versus Polyethylene Glycol-Based Lavage: A Multicenter Trial

    Directory of Open Access Journals (Sweden)

    S. Schanz

    2008-01-01

    Full Text Available Background: Adequate bowel preparation is essential for accurate colonoscopy. Both oral sodium phosphate (NaP and polyethylene glycol-based lavage (PEG-ELS are used predominantly as bowel cleansing modalities. NaP has gained popularity due to low drinking volume and lower costs. The purpose of this randomized multicenter observer blinded study was to compare three groups of cleansing (NaP, NaP + sennosides, PEG-ELS + sennosides in reference to tolerability, acceptance, and cleanliness. Patient and Methods: 355 outpatients between 18 and 75 years were randomized into three groups (A, B, C receiving NaP = A, NaP, and sennosides = B or PEG-ELS and sennosides = C. Gastroenterologists performing colonoscopies were blinded to the type of preparation. All patients documented tolerance and adverse events. Vital signs, premedication, completeness, discomfort, and complications were recorded. A quality score (0–4 of cleanliness was generated. Results: The three groups were similar with regard to age, sex, BMI, indication for colonoscopy, and comorbidity. Drinking volumes (L (A = 4.33 + 1.2, B = 4.56 + 1.18, C = 4.93 + 1.71 were in favor of NaP (P = .005. Discomfort from ingested fluid was recorded in A = 39.8% (versus C: P = .015, B = 46.6% (versus C: P = .147, and C = 54.6%. Differences in tolerability and acceptance between the three groups were statistically not significant. No differences in adverse events and the cleanliness effects occurred in the three groups (P = .113. The cleanliness quality scores 0–2 were calculated in A: 77.7%, B: 86.7%, and C: 85.2%. Conclusions: These data fail to demonstrate significant differences in tolerability, acceptance, and preparation quality between the three types of bowel preparation for colonoscopy. Cleansing with NaP was not superior to PEG-ELS.

  7. Impact of a simulation training curriculum on technical and nontechnical skills in colonoscopy: a randomized trial.

    Science.gov (United States)

    Grover, Samir C; Garg, Ankit; Scaffidi, Michael A; Yu, Jeffrey J; Plener, Ian S; Yong, Elaine; Cino, Maria; Grantcharov, Teodor P; Walsh, Catharine M

    2015-12-01

    GI endoscopy simulation-based training augments early clinical performance; however, the optimal manner by which to deliver training is unknown. We aimed to validate a simulation-based structured comprehensive curriculum (SCC) designed to teach technical, cognitive, and integrative competencies in colonoscopy. Single-blinded, randomized, controlled trial. Endoscopic simulation course at an academic hospital. Thirty-three novice endoscopists were allocated to an SCC group or self-regulated learning (SRL) group. The SCC group received a curriculum consisting of 6 hours of didactic lectures and 8 hours of virtual reality simulation-based training with expert feedback. The SRL group was provided a list of desired objectives and was instructed to practice on the simulator for an equivalent time (8 hours). Clinical transfer was assessed during 2 patient colonoscopies using the Joint Advisory Group Direct Observation of Procedural Skills (JAG DOPS) scale. Secondary outcome measures included differences in procedural knowledge, immediate post-training simulation performance, and delayed post-training (4-6 weeks) performance during an integrated scenario test on the JAG DOPS communication and integrated scenario global rating scales. There was no significant difference in baseline or post-training performance on the simulator task. The SCC group performed superiorly during their first and second clinical colonoscopies. Additionally, the SCC group demonstrated significantly better knowledge and colonoscopy-specific performance, communication, and global performance during the integrated scenario. We were unable to measure SRL participants' effort outside of mandatory training. In addition, feedback metrics and number of available simulation cases are limited. These results support integration of endoscopy simulation into a structured curriculum incorporating instructional feedback and complementary didactic knowledge as a means to augment technical, cognitive, and

  8. Benefits of Barium Enema in Patients with Incomplete Colonoscopy. Prospective Study of 45 Cases; Valor del enema de bario en pacientes con colonoscopia incompleta. Estudio prospectivo de 45 casos

    Energy Technology Data Exchange (ETDEWEB)

    Gispert, S.; Mayolas, N.; Hidalgo, A. [Hospital General Universitario Vall de Hebron. Barcelona (Spain)

    2003-07-01

    To evaluate the usefulness of barium enema in patients with incomplete colonoscopy. There was carried out a prospective 10-month study of 45 patients with incomplete colonoscopy (27 men and 18 women), who were later examined by means of barium enema (33 conventional, 12 double-contrast) in order to check for additional pathology in portions of the colon not visualized by colonoscopy. Barium enema diagnosed six possible additional lesions (13.3%) in portions of the colon not visualized by incomplete colonoscopy (four neoplasia and two non-neoplasia). Regarding the neoplasia two were true positives and two false positives. Both true positives were adenocarcinomas (one synchronous caecum, and another in splenic angle). The two false positives corresponded to fecal matter stuck to the intestinal wall. Regarding the non-neoplasia, multiple stenosis was detected in a patient with Crohn's disease and an enterocolic fistula was found in a patient with sigmoid colon neoplasia. The diagnostic yield of barium enema in the detection of additional pathology in colon portions not visualized by colonoscopy was of 9%. Barium enema following incomplete colonoscopy permits a complete colon evaluation in most cases, and it offers additional diagnostic information. (Author) 21 refs.

  9. Patient-to-patient transmission of hepatitis C virus (HCV) during colonoscopy diagnosis.

    Science.gov (United States)

    González-Candelas, Fernando; Guiral, Silvia; Carbó, Rosa; Valero, Ana; Vanaclocha, Hermelinda; González, Francisco; Bracho, Maria Alma

    2010-09-08

    No recognized risk factors can be identified in 10-40% of hepatitis C virus (HCV)-infected patients suggesting that the modes of transmission involved could be underestimated or unidentified. Invasive diagnostic procedures, such as endoscopy, have been considered as a potential HCV transmission route; although the actual extent of transmission in endoscopy procedures remains controversial. Most reported HCV outbreaks related to nosocomial acquisition have been attributed to unsafe injection practices and use of multi-dose vials. Only a few cases of likely patient-to-patient HCV transmission via a contaminated colonoscope have been reported to date. Nosocomial HCV infection may have important medical and legal implications and, therefore, possible transmission routes should be investigated. In this study, a case of nosocomial transmission of HCV from a common source to two patients who underwent colonoscopy in an endoscopy unit is reported. A retrospective epidemiological search after detection of index cases revealed several potentially infective procedures: sample blood collection, use of a peripheral catheter, anesthesia and colonoscopy procedures. The epidemiological investigation showed breaches in colonoscope reprocessing and deficiencies in the recording of valuable tracing data. Direct sequences from the NS5B region were obtained to determine the extent of the outbreak and cloned sequences from the E1-E2 region were used to establish the relationships among intrapatient viral populations. Phylogenetic analyses of individual sequences from viral populations infecting the three patients involved in the outbreak confirmed the patient pointed out by the epidemiological search as the source of the outbreak. Furthermore, the sequential order in which the patients underwent colonoscopy correlates with viral genetic variability estimates. Patient-to-patient transmission of HCV could be demonstrated although the precise route of transmission remained unclear. Viral

  10. Correlation of double-contrast high-density barium enema, colonoscopy, and histology in children with special attention to disparities

    International Nuclear Information System (INIS)

    Stringer, D.A.; Sherman, P.M.; Jakowenko, N.

    1986-01-01

    Colonscopic and double-contrast high-density barium enema (DCBE) findings were correlated in 68 patients (39 boys and 29 girls) aged 6 months to 18 years (mean 11.6 years) evaluated over a 24-month period. There was excellent correlation in 53 patients (78.0%) and good correlation in another 3 (4.4%) who had identical diagnoses and only slightly differing extent of disease reported. In 2 of these, DCBE showed more extensive disease, confirmed histologically in 1. Distal colitis seen on colonoscopy as reddening and neovascularity was missed on DCBE in 6 patients. Colonoscopy and DEBE failed to show a polyp in 1 patient each. One patient who had a normal DCBE and colonoscopy demonstrated a histological abnormality, and 1 patient with an abnormality on histology and DCBE was normal on colonscopy. A disparity resulted from the time between procedures in 1 patient and observer error in another. This high correlation is far better than any previously reported in children, supporting the use of high-density barium sulfate and double-contrast barium enemas in pediatric patients. (orig.)

  11. Polyethylene glycol 3350 without electrolytes: a new safe, effective, and palatable bowel preparation for colonoscopy in children.

    Science.gov (United States)

    Pashankar, Dinesh S; Uc, Aliye; Bishop, Warren P

    2004-03-01

    To assess safety, efficacy, and acceptance of polyethylene glycol 3350 without electrolytes (PEG) for bowel preparation for colonoscopy in children. Study design In a prospective study, 46 children (mean age, 11.2 years; range, 2.8-17.8) were given PEG at a dose of 1.5 g/kg/day for 4 days before colonoscopy. Patients were allowed to mix PEG in the beverage of their choice. Stool frequency and adverse effects were monitored during PEG therapy. Compliance, tolerance, and quality of colonic preparation were assessed. Serum electrolytes were measured before and after PEG therapy in 29 children. Daily stool frequency increased with PEG therapy from baseline of 2.6+/-0.3 to 3.0+/-0.5 on day 1, 4.6+/-0.4 on day 2, 5.5+/-0.7 on day 3, and 6.0+/-0.6 on day 4 (days 2, 3, and 4, PPEG therapy. Compliance and tolerance were rated as excellent by 89% and 85% of patients, respectively. Electrolyte-free PEG 3350 can be used as an effective and safe bowel preparation that is well accepted by children for colonoscopy.

  12. Effectiveness of Lay Health Worker Outreach in Reducing Disparities in Colorectal Cancer Screening in Vietnamese Americans

    Science.gov (United States)

    Stewart, Susan L.; Nguyen, Tung T.; Bui-Tong, Ngoc; McPhee, Stephen J.

    2015-01-01

    Objectives. We conducted a cluster randomized controlled study of a lay health worker (LHW) intervention to increase colorectal cancer (CRC) screening rates among Vietnamese Americans, who typically have lower rates than do non-Hispanic Whites. Methods. We randomized 64 LHWs to 2 arms. Each LHW recruited 10 male or female participants who had never had CRC screening (fecal occult blood test, sigmoidoscopy, or colonoscopy). Intervention LHWs led 2 educational sessions on CRC screening. Control LHWs led 2 sessions on healthy eating and physical activity. The main outcome was self-reported receipt of any CRC screening at 6 months after the intervention. We conducted the study from 2008 to 2013 in Santa Clara County, California. Results. A greater proportion of intervention participants (56%) than control participants (19%) reported receiving CRC screening (P Vietnamese Americans. Randomized controlled trials are needed to test the effectiveness of LHW outreach for other populations and other health outcomes. PMID:26270306

  13. A comparison of two different T-grain films in rare-earth screens with a standard film-screen combination for intravenous pyelography and bone examinations

    International Nuclear Information System (INIS)

    Logan, H.; Daly, L.; Masterson, J.

    1989-01-01

    T-grain film is claimed to give significantly improved image quality, allowing use of faster screens without loss of quality, thus reducing radiation dose. We tested this claim for two systems. In each case comparison was made with our usual screen-film combination, Agfa Curix RP1 film with Kodak Xomatic Regular screens (a nominally 200 speed system). The systems tested were Kodak TMatG in Kodak Lanex Medium screens (300 speed) and Agfa STG in Kodak Lanex Regular screens (400 speed). The Agfa STG-Lanex Regular system performed less well than the standard system for intravenous pyelograms (IVPs), bones and soft-tissue detail. Its speed advantage was not apparent below 70 kV. The Kodak TMatG-Lanex Medium system was better than the standard system for IVPs but not as good for bones. It gave virtually no speed advantage below 90 kV. Kodak T-grain film in a medium-speed, rare-earth screen was found to be better than the standard system for IVPs. Agfa T-grain film in a fast rare-earth screen was unsatisfactory for IVPs. Neither combination was as good as the standard system for bones. (author)

  14. Can the localization of primary colonic tumors be improved by staging CT without specific bowel preparation compared to optical colonoscopy?

    International Nuclear Information System (INIS)

    Feuerlein, Sebastian; Grimm, Lars J.; Davenport, Matthew S.; Haystead, Clare M.; Miller, Chad M.; Neville, Amy M.; Jaffe, Tracy A.

    2012-01-01

    Objectives: To investigate the ability of staging computed tomography (CT) without bowel preparation to accurately localize colonic tumors compared to optical colonoscopy. Methods: The local institutional review board approved this retrospective and HIPAA-compliant study. Forty-six patients with colonic adenocarcinoma, preoperative colonoscopy, and staging CT within 60 days of resection were included. Patients underwent contrast enhanced CT imaging without bowel preparation or oral contrast. The colon was divided into four segments with the operative reports used as the standard. Rectal and cecal cancers were excluded. CT scans were reviewed by 5 readers in a segmental binary fashion using a 5-point confidence scale in two sessions blinded and unblinded to the colonoscopy report. Results: At surgery 49 tumors were found in 46 patients. Readers detected 86.1%, 74.3%, and 66.9% of lesions with 92.0%, 94.1%, and 95.4% accuracy for confidence scores of ≥3, ≥4, and 5. CT interobserver agreement was good (κ = 0.82) for the unblinded and moderate (κ = 0.60) for the blinded read. Colonoscopic localization was only 78.7% accurate with 2 tumors undiscovered. Colonoscopic accuracy was low in the descending colon (57.1%) and the transverse colon (55.6%). Conclusions: Preoperative staging CT is more accurate than colonoscopy in the localization of colonic tumors

  15. A new composite measure of colonoscopy: the Performance Indicator of Colonic Intubation (PICI).

    Science.gov (United States)

    Valori, Roland M; Damery, Sarah; Gavin, Daniel R; Anderson, John T; Donnelly, Mark T; Williams, J Graham; Swarbrick, Edwin T

    2018-01-01

     Cecal intubation rate (CIR) is an established performance indicator of colonoscopy. In some patients, cecal intubation with acceptable tolerance is only achieved with additional sedation. This study proposes a composite Performance Indicator of Colonic Intubation (PICI), which combines CIR, comfort, and sedation. METHODS : Data from 20 085 colonoscopies reported in the 2011 UK national audit were analyzed. PICI was defined as the percentage of procedures achieving cecal intubation with median dose (2 mg) of midazolam or less, and nurse-assessed comfort score of 1 - 3/5. Multivariate logistic regression analysis evaluated possible associations between PICI and patient, unit, colonoscopist, and diagnostic factors. RESULTS : PICI was achieved in 54.1 % of procedures. PICI identified factors affecting performance more frequently than single measures such as CIR and polyp detection, or CIR + comfort alone. Older age, male sex, adequate bowel preparation, and a positive fecal occult blood test as indication were associated with a higher PICI. Unit accreditation, the presence of magnetic imagers in the unit, greater annual volume, fewer years' experience, and higher training/trainer status were associated with higher PICI rates. Procedures in which PICI was achieved were associated with significantly higher polyp detection rates than when PICI was not achieved. CONCLUSIONS : PICI provides a simpler picture of performance of colonoscopic intubation than separate measures of CIR, comfort, and sedation. It is associated with more factors that are amenable to change that might improve performance and with higher likelihood of polyp detection. It is proposed that PICI becomes the key performance indicator for intubation of the colon in colonoscopy quality improvement initiatives. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Colorectal cancer screening in patients with spinal cord injury yields similar results to the general population with an effective bowel preparation: a retrospective chart audit.

    Science.gov (United States)

    Teng, Brandon J; Song, Shawn H; Svircev, Jelena N; Dominitz, Jason A; Burns, Stephen P

    2018-03-01

    Retrospective chart audit. To compare adequacy of colonoscopy bowel preparation and diagnostic findings between persons with SCI receiving an extended inpatient bowel preparation and the general population. Veterans Affairs Puget Sound Healthcare System, Seattle, WA, USA. We reviewed an electronic database of all colonoscopies performed at a tertiary Veterans Affairs medical center between 7/12/13 and 15/10/15. Patients with SCI received a multi-day bowel preparation with magnesium citrate, and 8-10 liters of polyethylene glycol-3350 and electrolyte colonic lavage solution (PEG-ELS) over two and one half days. The control population received a standard bowel preparation consisting of magnesium citrate and 4 liters of PEG-ELS over 1 day. Two hundred and fifty-five patients were included in the study, including 85 patients with SCI. Average risk screening was a more common colonoscopy indication in patients with SCI vs. the control population (24 vs. 13% p = 0.03). There was no difference in adequacy of bowel preparation (87 vs. 85%, p = 0.73) or adenoma detection rate (55 vs. 51%, p = 0.59) when comparing patients with SCI with the control population. No difference in polyp histopathology was detected (p = 0.748). Our study demonstrated that an extended bowel preparation for patients with SCI produces similar bowel preparation results and diagnostic yield when compared to patients without SCI undergoing colonoscopy.

  17. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... virtual colonoscopy. Virtual colonoscopy is a diagnostic imaging test that is used to screen the large intestine ...

  18. Factors influencing participation in colorectal cancer screening programs in Spain.

    Science.gov (United States)

    Vanaclocha-Espi, Mercedes; Ibáñez, Josefa; Molina-Barceló, Ana; Pérez, Elena; Nolasco, Andreu; Font, Rebeca; Pérez-Riquelme, Francisco; de la Vega, Mariola; Arana-Arri, Eunate; Oceja, MªElena; Espinàs, Josep Alfons; Portillo, Isabel; Salas, Dolores

    2017-12-01

    To analyze the sociodemographic and organizational factors influencing participation in population-based colorectal cancer screening programs (CRCSP) in Spain, a retrospective study was conducted in a cohort of people invited to participate in the first 3 screening rounds of 6 CRCSP from 2000 to 2012. Mixed logistic regression models were used to analyze the relationship between sociodemographic and organizational factors, such as the type of fecal occult blood test (FOBT) used and the FOBT delivery type. The analysis was performed separately in groups (Initial screening-first invitation, Subsequent invitation for previous never-responders, Subsequent invitation-regular, Subsequent invitation-irregular intervals). The results showed that, in the Initial screening-first invitation group, participation was higher in women than in men in all age groups (OR 1.05 in persons aged 50-59years and OR 1.12 in those aged 60-69years). Participation was also higher when no action was required to receive the FOBT kit, independently of the type of screening (Initial screening-first invitation [OR 2.24], Subsequent invitation for previous never-responders [OR 2.14], Subsequent invitation-regular [OR 2.03], Subsequent invitation-irregular intervals [OR 9.38]) and when quantitative rather than qualitative immunological FOBT (FIT) was offered (Initial screening-first invitation [OR 0.70], Subsequent invitation for previous never-responders [OR 0.12], Subsequent invitation-regular [OR 0.20]) or guaiac testing (Initial screening-first invitation [OR 0.81], Subsequent invitation for previous never-responders [OR 0.88], Subsequent invitation-regular [OR 0.73]). In conclusion, the results of this study show that screening participation could be enhanced by inclusion of the FOBT kit with the screening invitation and the use of the quantitative FIT. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Can colorectal cancer mass-screening organization be evidence-based? Lessons from failures: The experimental and pilot phases of the Lazio program

    Directory of Open Access Journals (Sweden)

    Valle Sabrina

    2008-09-01

    Full Text Available Abstract Background Screening programmes should be organized to translate theoretical efficacy into effectiveness. An evidence-based organizational model of colorectal cancer screening (CRCS should assure feasibility and high compliance. Methods A multidisciplinary Working Group (WG, reviewed literature and guidelines to define evidence-based recommendations. The WG identified the need for further local studies: physicians' CRCS attitudes, the effect of test type and provider on compliance, and individual reasons for non-compliance. A survey of digestive endoscopy services was conducted. A feasibility study on a target population of 300.000 has begun. Results Based on the results of population trials and on literature review the screening strategy adopted was Faecal Occult Blood Test (FOBT every two years for 50–74 year olds and, for positives, colonoscopy. The immunochemical test was chosen because it has 20% higher compliance than the Guaiac. GPs were chosen as the preferred provider also for higher compliance. Since we observed that distance is the major determinant of non-compliance, we choose GPs because they are the closest providers, both geographically and emotionally, to the public. The feasibility study showed several barriers: GP participation was low, there were administrative problems to involve GPs; opportunistic testing by the GPs; difficulties in access to Gastroenterology centres; difficulties in gathering colonoscopy results; little time given to screening activity by the gastroenterology centre. Conclusion The feasibility study highlighted several limits of the model. Most of the barriers that emerged were consequences of organisational choices not supported by evidence. The principal limit was a lack of accountability by the participating centres.

  20. Is "really conscious" sedation with solely an opioid an alternative to every day used sedation regimes for colonoscopies in a teaching hospital? Midazolam/fentanyl, propofol/alfentanil, or alfentanil only for colonoscopy: a randomized trial

    NARCIS (Netherlands)

    Eberl, S.; Polderman, J. A. W.; Preckel, B.; Kalkman, C. J.; Fockens, P.; Hollmann, M. W.

    2014-01-01

    We investigated the satisfaction of patients and endoscopists and concurrently safety aspects of an "alfentanil only" and two clinically routinely used sedation regimes in patients undergoing colonoscopy in a teaching hospital. One hundred and eighty patients were prospectively randomized in three

  1. Long-term follow-up reveals high incidence of colorectal cancer in Indian patients with inflammatory bowel disease.

    Science.gov (United States)

    Bopanna, Sawan; Kedia, Saurabh; Das, Prasenjit; Dattagupta, S; Sreenivas, V; Mouli, V Pratap; Dhingra, Rajan; Pradhan, Rajesh; Kumar, N Suraj; Yadav, Dawesh P; Makharia, Govind; Ahuja, Vineet

    2017-08-01

    As the magnitude of sporadic colorectal cancer (CRC) in India is low, magnitude of CRC in ulcerative colitis (UC) is also considered low. As a result, screening for CRC in UC although advocated may not be followed everywhere. We report our data of UC-related CRC from a low-incidence area of sporadic CRC. A total of 1012 patients with left-sided colitis/pancolitis having more than one full-length colonoscopy performed at least a year after the onset of symptoms were included in retrospective analysis of prospectively maintained case records. In addition, 136 patients with duration of disease >10 years underwent surveillance white-light colonoscopy prospectively during the study period. A total of 1012 individuals were finally included (6542 person-years of follow-up, 68.5% males, disease duration: 6.4 ± 6.8 years). Twenty (1.97%) patients developed CRC. Two (10%) patients developed CRC during the first decade, 10/20 (50%) during the second and 8/20 (40%) after the second decade of disease. The cumulative risk of developing CRC was 1.5%, 7.2% and 23.6% in the first, second and third decade, respectively. Of 136 high-risk UC cases, five (3.6%) had CRC on screening colonoscopy. Disease duration and increasing age of onset were associated with higher risk of CRC. Cumulative risk of CRC in Indian UC patients is as high as 23.6% at 30 years. The risk of CRC increases with increasing age of onset and increasing duration of disease. A low risk of sporadic CRC does not confer a low risk of UC-related CRC, and regular screening is warranted.

  2. Psychomotor and cognitive effects of 15-minute inhalation of methoxyflurane in healthy volunteers: implication for post-colonoscopy care.

    Science.gov (United States)

    Nguyen, Nam Q; Burgess, Jenna; Debreceni, Tamara L; Toscano, Leanne

    2016-11-01

    Background and study aims: Colonoscopy with portal inhaled methoxyflurane (Penthrox) is highly feasible with low sedation risk and allows earlier discharge. It is unclear if subjects can return to highly skilled psychomotor skill task shortly after Penthrox assisted colonoscopy. We evaluated the psychomotor and cognitive effects of 15-minute inhalation of Penthrox in adults. Patients and methods: Sixty healthy volunteers (18 to 80 years) were studied on 2 occasions with either Penthrox or placebo in a randomized, double-blind fashion. On each occasion, the subject's psychomotor function was examined before, immediately, 30, 60, 120, 180 and 240 min after a 15-minute inhalation of studied drug, using validated psychomotor tests (Digit Symbol Substitution Test (DSST), auditory reaction time (ART), eye-hand coordination (EHC) test, trail making test (TMT) and logical reasoning test (LRT). Results: Compared to placebo, a 15-minute Penthrox inhalation led to an immediate but small impairment of DSST ( P  returns to normal within 30 minutes , indicating that subjects who have colonoscopy with Penthrox can return to highly skilled psychomotor skills tasks such as driving and daily work the same day.

  3. A randomized, controlled, double-blind trial of the adjunct use of Clebopride in polyethylene glycol electrolyte (PEG) solution for colonoscopy preparation.

    Science.gov (United States)

    Abdullah, Murdani; Rani, A Aziz; Fauzi, Achmad; Syam, Ari Fahrial; Makmun, Dadang; Simadibrata, Marcellus; Manan, Chudahman; Harjodisastro, Daldiyono

    2010-01-01

    To study the benefit of Clebopride as an adjuvant in polyethylene glycol electrolyte (PEG) solution for colonoscopy preparation. Eighty one adult patients who underwent colonoscopy examination were recruited in this randomized double blind controlled study. First group received PEG and placebo, whereas second group received PEG and Clebopride. Two litres of PEG was taken at night before colonoscopy. The acceptability and tolerability of bowel preparation were assessed through interview method. The efficacy of bowel preparation was assessed using Aronchick's Criteria. In terms of acceptability, 64 patients (31 patients from placebo group vs 33 patients from Clebopride group) were able to drink two litres of PEG solution. Sixty patients (29 patients from placebo group and 31 patients from Clebopride group) were willing to accept PEG solution for their next bowel preparation. On the term of tolerability, nausea, abdominal distension, and borborygmus were more frequent in the placebo group (34.2% vs 27.9%; 44.7% vs 32.6%; 26.3% vs 4.6% respectively). However, only the difference at the incidence of borborygmus that was statistically significant (pClebopride group and 81.6% of bowel preparation in placebo group were optimal (p = 0.585). The adjunct use of Clebopride in PEG solution for colonoscopy preparations tends to increase the acceptability, tolerability, and efficacy. The presence of borborygmus was significantly lower in the Clebopride group.

  4. Screening adherence and cancer risk perceptions in colorectal cancer survivors with Lynch-like syndrome.

    Science.gov (United States)

    Katz, L H; Burton-Chase, A M; Advani, S; Fellman, B; Polivka, K M; Yuan, Y; Lynch, P M; Peterson, S K

    2016-03-01

    Cancer screening recommendations for patients with Lynch-like syndrome (LLS) are not well defined. We evaluated adherence to Lynch syndrome (LS) screening recommendations, cancer risk perceptions, and communication within the families among colorectal cancer (CRC) survivors with LLS. Thirty-four participants with LLS completed a questionnaire about risk perception, adherence to LS screening recommendations, and communication with relatives. Clinical data were obtained from medical records. Most participants (76%) believed they should undergo colonoscopy every 1-2 years. Only 41% correctly interpreted their genetic tests as uninformative negative or as variant of unknown significance for LS. Less than half had had an upper gastrointestinal endoscopy for screening purpose. Among female participants, 86% had been screened for endometrial cancer (EC) and 71% for ovarian cancer. Most participants had informed relatives about the CRC diagnosis and advised them to undergo CRC screening, but only 50% advised female relatives to be screened for EC and only one-third advised relatives to have genetic counseling. Most CRC survivors with LLS follow the same cancer screening recommended for LS patients but do not understand the meaning of LLS. Greater care must be devoted to communicating the implications of nondiagnostic germline mutation testing among patients with LLS. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Primary care characteristics and their association with health screening in a low-socioeconomic status public rental-flat population in Singapore- a mixed methods study.

    Science.gov (United States)

    Wee, Liang En; Cher, Wen Qi; Sin, David; Li, Zong Chen; Koh, Gerald Choon-Huat

    2016-02-06

    In Singapore, subsidized primary care is provided by centralized polyclinics; since 2000, policies have allowed lower-income Singaporeans to utilize subsidies at private general-practitioner (GP) clinics. We sought to determine whether proximity to primary care, subsidised primary care, or having regular primary care associated with health screening participation in a low socioeconomic-status public rental-flat community in Singapore. From 2009-2014, residents in five public rental-flat enclaves (N = 936) and neighboring owner-occupied precincts (N = 1060) were assessed for participation in cardiovascular and cancer screening. We then evaluated whether proximity to primary care, subsidised primary care, or having regular primary care associated with improved adherence to health screening. We also investigated attitudes to health screening using qualitative methodology. In the rental flat population, for cardiovascular screening, regular primary care was independently associated with regular diabetes screening (adjusted odds ratio, aOR = 1.59, CI = 1.12-2.26, p = 0.009) and hyperlipidemia screening (aOR = 1.82, CI = 1.10-3.04, p = 0.023). In the owner-occupied flats, regular primary care was independently associated with regular hypertension screening (aOR = 9.34 (1.82-47.85, p = 0.007), while subsidized primary care was associated with regular diabetes screening (aOR = 2.94, CI = 1.04-8.31, p = 0.042). For cancer screening, in the rental flat population, proximity to primary care was associated with less participation in regular colorectal cancer screening (aOR = 0.42, CI = 0.17-0.99, p = 0.049) and breast cancer screening (aOR = 0.29, CI = 0.10-0.84, p = 0.023). In the owner-occupied flat population, for gynecological cancer screening, usage of subsidized primary care and proximity to primary care was associated with higher rates of breast cancer and cervical cancer screening; however

  6. Implications of false-positive results for future cancer screenings.

    Science.gov (United States)

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both Pfalse-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; Pfalse-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  7. Multilevel predictors of colorectal cancer testing modality among publicly and privately insured people turning 50

    Directory of Open Access Journals (Sweden)

    Stephanie B. Wheeler

    2017-06-01

    Both colonoscopy and FOBT/FIT are widely used in North Carolina among insured persons newly age-eligible for screening. The high level of FOBT/FIT use among privately insured persons and women suggests that renewed emphasis on FOBT/FIT as a viable screening alternative to colonoscopy may be important.

  8. Colorectal cancer screening: strategies to select populations with moderate risk for disease Cribado del cáncer colorrectal: estrategias para seleccionar a poblaciones con un riesgo moderado para esta enfermedad

    Directory of Open Access Journals (Sweden)

    M. Navarro

    2009-12-01

    Full Text Available Objective: to analyse the association between rectal bleeding or a family history of colorectal cancer (CRC and the results obtained in two rounds of a CRC screening pilot programme performed in L'Hospitalet, Barcelona, Spain. Subjects: males and females (50-69 years were the target population. Together with the invitation letter, they received a questionnaire in which they were askaed about rectal bleeding, family history of CRC and related neoplasms. The screening test was a guaiac-based faecal occult blood test (FOBT, and colonoscopy for positive tests. Results: 25,829 FOBT were performed in 18,405 individuals. Information on rectal bleeding and a family history of CRC were obtained for 9,849 and 9,865 cases, respectively. Male sex (OR = 1.32, 60-69 years of age (OR = 1.48, rectal bleeding (OR = 1.84 and history of CRC (OR = 1.54 were independent predictors of positive FOBT. With regard to colonoscopy, a greater risk of diagnosing advanced neoplasm was observed among men (OR = 2.47 and subjects with a family history of CRC (OR = 1.98. Conclusions: CRC screening programmes must have instruments that make it possible to select the candidate population and the possibility of offering a study suited to the risk of individuals who are not susceptible to population screening by means of FOBT.

  9. Colonoscopy

    Science.gov (United States)

    ... passed up to the colon. Small amounts of air are inserted to open the colon and allow viewing of the surrounding area. The tube has a light and camera at the end and sends a picture to a TV screen. Your heart rate, breathing, and oxygen level will ...

  10. Appendiceal Abscesses Reduced in Size by Drainage of Pus from the Appendiceal Orifice during Colonoscopy: A Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Shinjiro Kobayashi

    2014-11-01

    Full Text Available Interval appendectomy (IA for appendiceal abscesses is useful for avoiding extended surgery and preventing postoperative complications. However, IA has problems in that it takes time before an abscess is reduced in size in some cases and in that elective surgery may result in a delay in treatment in patients with a malignant tumor of the appendix. In order to rule out malignancy, we performed colonoscopy on three patients with an appendiceal abscess that did not decrease in size 5 or more days after IA. After malignancy had been ruled out by examination of the area of the appendiceal orifice, the appendiceal orifice was compressed with a colonoscope, and a catheter was inserted through the orifice. Then, drainage of pus was observed from the appendiceal orifice into the cecal lumen. Computed tomography performed 3 days after colonoscopy revealed a marked reduction in abscess size in all patients. No endoscopy-related complication was noted. Colonoscopy in patients with an appendiceal abscess may not only differentiate malignant tumors, but also accelerate reduction in abscess size.

  11. Long-term performance of colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Hassan, Cesare; Capodaglio, Giulia; Fedato, Chiara; Montaguti, Adriana; Turrin, Anna; Rosano, Alberto; Monetti, Daniele; Stocco, Carmen; Baracco, Susanna; Russo, Francesca; Repici, Alessandro; Rugge, Massimo

    2017-11-03

    The long-term performance of colorectal cancer (CRC) screening programmes based on a 2-year faecal immunochemical test (FIT) is still unclear. In a sample of 50 to 69-year-olds repeatedly screened with the FIT (OC-Hemodia latex agglutination test; cut-off: 20 µg haemoglobin/g faeces), we examined: (1) the FIT positivity rate, the CRC and advanced adenoma detection rate and the FIT's positive predictive value (PPV) for advanced neoplasia, at each round of screening and (2) the cumulative CRC and advanced adenoma detection rate after five rounds of FIT. Over 12 years (2002-2014), 123 347 individuals were administered the FIT up to six times, and 781 CRCs and 4713 advanced adenomas were diagnosed. The CRC and advanced adenoma detection rates declined substantially from the first to the third (rate ratio (RR) 0.25, 95% CI 0.20 to 0.32) and second (RR 0.51, 95% CI 0.47 to 0.56) rounds, respectively, and then remained stable. The PPV for advanced neoplasia dropped by 18% in the second round (RR 0.82, 95% CI 0.77 to 0.89), with no further reduction thereafter due to a concomitant decline in the FIT positivity rate (RR first to sixth rounds: 0.56, 95% CI 0.53 to 0.60).The cumulative CRC and advanced adenoma detection rates over five consecutive rounds were 8.5‰ (95% CI 7.8 to 9.2), and 58.9‰ (95% CI 56.9 to 61.0), respectively. Repeated FIT significantly reduces the burden of colorectal disease while facilitating an efficient use of colonoscopy resources. The cumulative detection rate after five rounds of FIT is similar to primary screening with colonoscopy, supporting the need to account for the cumulative sensitivity of repeated FITs when evaluating the test's efficacy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Implementation of an optical diagnosis strategy saves costs and does not impair clinical outcomes of a fecal immunochemical test-based colorectal cancer screening program.

    Science.gov (United States)

    Vleugels, Jasper L A; Greuter, Marjolein J E; Hazewinkel, Yark; Coupé, Veerle M H; Dekker, Evelien

    2017-12-01

     In an optical diagnosis strategy, diminutive polyps that are endoscopically characterized with high confidence are removed without histopathological analysis and distal hyperplastic polyps are left in situ. We evaluated the effectiveness and costs of optical diagnosis.  Using the Adenoma and Serrated pathway to Colorectal CAncer (ASCCA) model, we simulated biennial fecal immunochemical test (FIT) screening in individuals aged 55 - 75 years. In this program, we compared an optical diagnosis strategy with current histopathology assessment of all diminutive polyps. Base-case assumptions included 76 % high-confidence predictions and sensitivities of 88 %, 91 %, and 88 % for endoscopically characterizing adenomas, sessile serrated polyps, and hyperplastic polyps, respectively. Outcomes were colorectal cancer burden, number of colonoscopies, life-years, and costs.  Both the histopathology strategy and the optical diagnosis strategy resulted in 21 life-days gained per simulated individual compared with no screening. For optical diagnosis, €6 per individual was saved compared with the current histopathology strategy. These cost savings were related to a 31 % reduction in colonoscopies in which histopathology was needed for diminutive polyps. Projecting these results onto the Netherlands (17 million inhabitants), assuming a fully implemented FIT-based screening program, resulted in an annual undiscounted cost saving of € 1.7 - 2.2 million for optical diagnosis.  Implementation of optical diagnosis in a FIT-based screening program saves costs without decreasing program effectiveness when compared with current histopathology analysis of all diminutive polyps. Further work is required to evaluate how endoscopists participating in a screening program should be trained, audited, and monitored to achieve adequate competence in optical diagnosis.

  13. Evaluation of a clinical risk index for advanced colorectal neoplasia among a North American population of screening age.

    Science.gov (United States)

    Ruco, Arlinda; Stock, David; Hilsden, Robert J; McGregor, S Elizabeth; Paszat, Lawrence F; Saskin, Refik; Rabeneck, Linda

    2015-11-19

    A clinical risk index employing age, sex, family history of colorectal cancer (CRC), smoking history and body mass index (BMI) may be useful for prioritizing screening with colonoscopy. The aim of this study was to conduct an external evaluation of a previously published risk index for advanced neoplasia (AN) in a large, well-characterized cohort. Five thousand one hundred thirty-seven asymptomatic persons aged 50 to 74 (54.9 % women) with a mean age (SD) of 58.3 (6.2) years were recruited for the study from a teaching hospital and colorectal cancer screening centre between 2003 and 2011. All participants underwent a complete screening colonoscopy and removal of all polyps. AN was defined as cancer or a tubular adenoma, traditional serrated adenoma (TSA), or sessile serrated adenoma (SSA) with villous characteristics (≥25% villous component), and/or high-grade dysplasia and/or diameter ≥10 mm. Risk scores for each participant were summed to derive an overall score (0-8). The c-statistic was used to measure discriminating ability of the risk index. The prevalence of AN in the study cohort was 6.8 %. The likelihood of detecting AN increased from 3.6 to 13.1 % for those with a risk score of 1 to 6 respectively. The c-statistic for the multivariable logistic model in our cohort was 0.64 (95 % CI = 0.61-067) indicating modest overlap between risk scores. The risk index for AN using age, sex, family history, smoking history and BMI was found to be of limited discriminating ability upon external validation. The index requires further refinement to better predict AN in average risk persons of screening age.

  14. Ameboma: A Colon Carcinoma-Like Lesion in a Colonoscopy Finding

    Directory of Open Access Journals (Sweden)

    Chung-Cheng Lin

    2013-10-01

    Full Text Available Ameboma is a rare complication of amebic colitis presenting as a mass of granulation tissue with peripheral fibrosis and a core of inflammation related to amebic chronic infection. The initial presentations are usually obstruction and low gastrointestinal bleeding. The most common sites are the ascending colon and the cecum. It may mimic colon carcinoma, Crohn's disease, carcinoma of the colon, non-Hodgkin's lymphoma, tuberculosis, fungal infection, AIDS-associated lymphoma and Kaposi's sarcoma in colonoscopy findings. The therapeutic strategy should be combined with antibiotics for invasive dysentery and eradication of luminal cysts.

  15. A comparative study of standard vs. high definition colonoscopy for adenoma and hyperplastic polyp detection with optimized withdrawal technique.

    Science.gov (United States)

    East, J E; Stavrindis, M; Thomas-Gibson, S; Guenther, T; Tekkis, P P; Saunders, B P

    2008-09-15

    Colonoscopy has a known miss rate for polyps and adenomas. High definition (HD) colonoscopes may allow detection of subtle mucosal change, potentially aiding detection of adenomas and hyperplastic polyps. To compare detection rates between HD and standard definition (SD) colonoscopy. Prospective, cohort study with optimized withdrawal technique (withdrawal time >6 min, antispasmodic, position changes, re-examining flexures and folds). One hundred and thirty patients attending for routine colonoscopy were examined with either SD (n = 72) or HD (n = 58) colonoscopes. Groups were well matched. Sixty per cent of patients had at least one adenoma detected with SD vs. 71% with HD, P = 0.20, relative risk (benefit) 1.32 (95% CI 0.85-2.04). Eighty-eight adenomas (mean +/- standard deviation 1.2 +/- 1.4) were detected using SD vs. 93 (1.6 +/- 1.5) with HD, P = 0.12; however more nonflat, diminutive (9 mm) hyperplastic polyps was 7% (0.09 +/- 0.36). High definition did not lead to a significant increase in adenoma or hyperplastic polyp detection, but may help where comprehensive lesion detection is paramount. High detection rates appear possible with either SD or HD, when using an optimized withdrawal technique.

  16. [Intestinal cleaning for colonoscopy in children: effectiveness, adherence and adverse effects of schemes differentiated by age].

    Science.gov (United States)

    Miquel, Isabel; Arancibia, María Eugenia; Alliende, Francisco; Ríos, Gloria; Rodríguez, Lorena; Lucero, Yalda; Saelzer, Eric

    2017-04-01

    Adequate intestinal cleanliness is crucial to achieve optimal colonoscopy performance. Several bowel preparation (BP) schemes have been proposed, but there is still no consensus as regards which is the most suitable in paediatric patients. To describe the effectiveness, adherence, and adverse effects of BP protocols differentiated by age group in paediatric patients subjected to colonoscopy. Prospective, study that included patients PEG 3350 without electrolytes); 4y-9y 11 m (PEG 3350 without electrolytes + bisacodyl); 10 y-18 y (PEG 3350 with electrolytes). Demographic, clinical information, adherence and adverse effects were registered. Effectiveness was determined using a validated scale (Boston modified) during colonoscopy. A total of 159 patients were included, of which 87 (55%) were males, and with a median age of 4 years (range 1 m-17 years). Seventy eight percent of patients achieved successful BP. The higher effectiveness was observed in the groups of < 6 m (96%) and 10-18 y (91%). Constipation was significantly more frequent (29%) in the 4 yo-9 yo 11 m in which lower effectiveness was observed (69%). Good adherence was observed in 87% of patients. Adverse effects were observed in a third of patients, although they were mild and did not lead to the suspension of the BP. Satisfactory results were achieved with the BP schemes used, with a successful BP being obtained in 4 out of 5 patients. Results were different between groups, which is probably related to previous bowel transit and indicated medication.

  17. Prostate Cancer Screening in Jamaica: Results of the Largest National Screening Clinic Prostate Cancer Screening in Jamaica: Results of the Largest National Screening Clinic

    International Nuclear Information System (INIS)

    Morrison, B. F.; Aiken, W.; Mayhew, R.; Gordon, Y.; Reid, M.

    2016-01-01

    Prostate cancer is highly prevalent in Jamaica and is the leading cause of cancer-related deaths. Our aim was to evaluate the patterns of screening in the largest organized screening clinic in Jamaica at the Jamaica Cancer Society. A retrospective analysis of all men presenting for screening at the Jamaica Cancer Society from 1995 to 2005 was done. All patients had digital rectal examinations (DRE) and prostate specific antigen (PSA) tests done. Results of prostate biopsies were noted. 1117 men of mean age 59.9 ± 8.2 years presented for screening. The median documented PSA was 1.6 ng/mL (maximum of 5170 ng/mL). Most patients presented for only 1 screen. There was a gradual reduction in the mean age of presentation for screening over the period. Prostate biopsies were requested on 11% of screening visits; however, only 59% of these were done. 5.6% of all persons screened were found to have cancer. Of the cancers diagnosed, Gleason 6 adenocarcinoma was the commonest grade and median PSA was 8.9 ng/mL (range 1.5-1059 ng/mL). Older men tend to screen for prostate cancer in Jamaica. However, compliance with regular maintenance visits and requests for confirmatory biopsies are poor. Screening needs intervention in the Jamaican population.

  18. Diverse Regular Employees and Non-regular Employment (Japanese)

    OpenAIRE

    MORISHIMA Motohiro

    2011-01-01

    Currently there are high expectations for the introduction of policies related to diverse regular employees. These policies are a response to the problem of disparities between regular and non-regular employees (part-time, temporary, contract and other non-regular employees) and will make it more likely that workers can balance work and their private lives while companies benefit from the advantages of regular employment. In this paper, I look at two issues that underlie this discussion. The ...

  19. Using motion capture to assess colonoscopy experience level

    DEFF Research Database (Denmark)

    Svendsen, Morten Bo Søndergaard; Preisler, Louise; Hillingsø, Jens Georg

    2014-01-01

    AIM: To study technical skills of colonoscopists using a Microsoft Kinect™ for motion analysis to develop a tool to guide colonoscopy education. RESULTS: Ten experienced endoscopists (gastroenterologists, n = 2; colorectal surgeons, n = 8) and 11 novices participated in the study. A Microsoft......) vs 12% for novice endoscopists (SD 9)], the level of the right hand below the sighting line (z-axis) (25 cm for experienced endoscopists vs 36 cm for novice endoscopists, P level of the left hand below the z-axis (6 cm for experienced endoscopists vs 15 cm for novice endoscopists, P...... experienced and novice endoscopists and to provide non-biased feedback. Whether it is possible to use this tool to train novices in a clinical setting requires further study....

  20. Surprising finding on colonoscopy.

    Science.gov (United States)

    Griglione, Nicole; Naik, Jahnavi; Christie, Jennifer

    2010-02-01

    A 48-year-old man went to his primary care physician for his annual physical. He told his physician that for the past few years, he had intermittent, painless rectal bleeding consisting of small amounts of blood on the toilet paper after defecation. He also mentioned that he often spontaneously awoke, very early in the morning. His past medical history was unremarkable. The patient was born in Cuba but had lived in the United States for more than 30 years. He was divorced, lived alone, and had no children. He had traveled to Latin America-including Mexico, Brazil, and Cuba-off and on over the past 10 years. His last trip was approximately 2 years ago. His physical exam was unremarkable. Rectal examination revealed no masses or external hemorrhoids; stool was brown and Hemoccult negative. Labs were remarkable for eosinophilia ranging from 10% to 24% over the past several years (the white blood cell count ranged from 5200 to 5900/mcL). A subsequent colonoscopy revealed many white, thin, motile organisms dispersed throughout the colon. The organisms were most densely populated in the cecum. Of note, the patient also had nonbleeding internal hemorrhoids. An aspiration of the organisms was obtained and sent to the microbiology lab for further evaluation. What is your diagnosis? How would you manage this condition?

  1. Cost-effectiveness analysis of the optimal threshold of an automated immunochemical test for colorectal cancer screening: performances of immunochemical colorectal cancer screening.

    Science.gov (United States)

    Berchi, Célia; Guittet, Lydia; Bouvier, Véronique; Launoy, Guy

    2010-01-01

    Most industrialized countries, including France, have undertaken to generalize colorectal cancer screening using guaiac fecal occult blood tests (G-FOBT). However, recent researches demonstrate that immunochemical fecal occult blood tests (I-FOBT) are more effective than G-FOBT. Moreover, new generation I-FOBT benefits from a quantitative reading technique allowing the positivity threshold to be chosen, hence offering the best balance between effectiveness and cost. We aimed at comparing the cost and the clinical performance of one round of screening using I-FOBT at different positivity thresholds to those obtained with G-FOBT to determine the optimal cut-off for I-FOBT. Data were derived from an experiment conducted from June 2004 to December 2005 in Calvados (France) where 20,322 inhabitants aged 50-74 years performed both I-FOBT and G-FOBT. Clinical performance was assessed by the number of advanced tumors screened, including large adenomas and cancers. Costs were assessed by the French Social Security Board and included only direct costs. Screening using I-FOBT resulted in better health outcomes and lower costs than screening using G-FOBT for thresholds comprised between 75 and 93 ng/ml. I-FOBT at 55 ng/ml also offers a satisfactory alternative to G-FOBT, because it is 1.8-fold more effective than G-FOBT, without increasing the number of unnecessary colonoscopies, and at an extra cost of 2,519 euros per advanced tumor screened. The use of an automated I-FOBT at 75 ng/ml would guarantee more efficient screening than currently used G-FOBT. Health authorities in industrialized countries should consider the replacement of G-FOBT by an automated I-FOBT test in the near future.

  2. Review of the Lynch syndrome: history, molecular genetics, screening, differential diagnosis, and medicolegal ramifications

    Science.gov (United States)

    Lynch, HT; Lynch, PM; Lanspa, SJ; Snyder, CL; Lynch, JF; Boland, CR

    2010-01-01

    More than one million patients will manifest colorectal cancer (CRC) this year of which, conservatively, approximately 3% (~30,700 cases) will have Lynch syndrome (LS), the most common hereditary CRC predisposing syndrome. Each case belongs to a family with clinical needs that require genetic counseling, DNA testing for mismatch repair genes (most frequently MLH1 or MSH2) and screening for CRC. Colonoscopy is mandated, given CRC’s proximal occurrence (70–80% proximal to the splenic flexure). Due to its early age of onset (average 45 years of age), colonoscopy needs to start by age 25, and because of its accelerated carcinogenesis, it should be repeated every 1 to 2 years through age 40 and then annually thereafter. Should CRC occur, subtotal colectomy may be necessary, given the marked frequency of synchronous and metachronous CRC. Because 40–60% of female patients will manifest endometrial cancer, tailored management is essential. Additional extracolonic cancers include ovary, stomach, small bowel, pancreas, hepatobiliary tract, upper uroepithelial tract, brain (Turcot variant) and sebaceous adenomas/carcinomas (Muir-Torre variant). LS explains only 10–25% of familial CRC. PMID:19659756

  3. Medicare Cancer Screening in the Context of Clinical Guidelines: 2000 to 2012.

    Science.gov (United States)

    Maroongroge, Sean; Yu, James B

    2018-04-01

    Cancer screening is a ubiquitous and controversial public health issue, particularly in the elderly population. Despite extensive evidence-based guidelines for screening, it is unclear how cancer screening has changed in the Medicare population over time. We characterize trends in cancer screening for the most common cancer types in the Medicare fee-for-service (FFS) program in the context of conflicting guidelines from 2000 to 2012. We performed a descriptive analysis of retrospective claims data from the Medicare FFS program based on billing codes. Our data include all claims for Medicare part B beneficiaries who received breast, colorectal (CRC), or prostate cancer screening from 2000 to 2012 based on billing codes. We utilize a Monte Carlo permutation method to detect changes in screening trends. In total, 231,416,732 screening tests were analyzed from 2000 to 2012, representing an average of 436.8 tests per 1000 beneficiaries per year. Mammography rates declined 7.4%, with digital mammography extensively replacing film. CRC cancer screening rates declined overall. As a percentage of all CRC screening tests, colonoscopy grew from 32% to 71%. Prostate screening rates increased 16% from 2000 to 2007, and then declined to 7% less than its 2000 rate by 2012. Both the aggressiveness of screening guidelines and screening rates for the Medicare FFS population peaked and then declined from 2000 to 2012. However, guideline publications did not consistently precede utilization trend shifts. Technology adoption, practical and financial concerns, and patient preferences may have also contributed to the observed trends. Further research should be performed on the impact of multiple, conflicting guidelines in cancer screening.

  4. Cystic Fibrosis Colorectal Cancer Screening Consensus Recommendations.

    Science.gov (United States)

    Hadjiliadis, Denis; Khoruts, Alexander; Zauber, Ann G; Hempstead, Sarah E; Maisonneuve, Patrick; Lowenfels, Albert B

    2018-02-01

    Improved therapy has substantially increased survival of persons with cystic fibrosis (CF). But the risk of colorectal cancer (CRC) in adults with CF is 5-10 times greater compared to the general population, and 25-30 times greater in CF patients after an organ transplantation. To address this risk, the CF Foundation convened a multi-stakeholder task force to develop CRC screening recommendations. The 18-member task force consisted of experts including pulmonologists, gastroenterologists, a social worker, nurse coordinator, surgeon, epidemiologist, statistician, CF adult, and a parent. The committee comprised 3 workgroups: Cancer Risk, Transplant, and Procedure and Preparation. A guidelines specialist at the CF Foundation conducted an evidence synthesis February-March 2016 based on PubMed literature searches. Task force members conducted additional independent searches. A total of 1159 articles were retrieved. After initial screening, the committee read 198 articles in full and analyzed 123 articles to develop recommendation statements. An independent decision analysis evaluating the benefits of screening relative to harms and resources required was conducted by the Department of Public Health at Erasmus Medical Center, Netherlands using the Microsimulation Screening Analysis model from the Cancer Innervation and Surveillance Modeling Network. The task force included recommendation statements in the final guideline only if they reached an 80% acceptance threshold. The task force makes 10 CRC screening recommendations that emphasize shared, individualized decision-making and familiarity with CF-specific gastrointestinal challenges. We recommend colonoscopy as the preferred screening method, initiation of screening at age 40 years, 5-year re-screening and 3-year surveillance intervals (unless shorter interval is indicated by individual findings), and a CF-specific intensive bowel preparation. Organ transplant recipients with CF should initiate CRC screening

  5. Commonly Used Preparations for Colonoscopy: Efficacy, Tolerability and Safety – A Canadian Association of Gastroenterology Position Paper

    Directory of Open Access Journals (Sweden)

    Alan Barkun

    2006-01-01

    Full Text Available INTRODUCTION: The increased demand for colonoscopy, coupled with the introduction of new bowel cleansing preparations and recent caution advisories in Canada, has prompted a review of bowel preparations by the Canadian Association of Gastroenterology.

  6. Applicable observation of butorphanol in painless colonoscopy examination

    Directory of Open Access Journals (Sweden)

    Li Xuefeng

    2017-01-01

    Full Text Available Objective:To summarize the clinical effect of butorphanol compound propofol in painless colonoscopy examination and its feasibility.Methods:100 colonoscopy examination patients (56 males and 44 females aged from 19 to 60 years old registered between August, 2016 and September, 2016 in the endoscopy center of our hospital were randomly selected. ASA classification is I or II level. Their body weight ranged from 55 kg to 75kg. They were randomly divided into two groups and each group included 50 cases. All patients went through conventional ambrosia and liquid fasting for 8 hours before the anesthesia and they drank magnesium sulfate liquid of 2500ml to clean their gastrointestinal tracts.After patients entered the operating room, their veins of upper limb were opened so as to monitor their HR, MAP and SPO2. After that, butorphanol of 20μg/kg was injected to patients of the experimental group while normal saline of the same amount of was injected to patients of the contrast group. After 60 seconds, propofol of 1~2 mg/kg was injected to both groups by the way of intravenous injection. The enteroscopy examination was started after patients had no eyelash reflection. Besides, actual application dose of propofol was adjusted according to clinical indications of patients and the adjusting frequency each time was controlled between 30 milligrams and 50 milligrams until the completion of the examination. SPSS 22.0 statistical software was used to analyze and handle research data of this group. Results:Anesthesia effect: The difference of inter-group comparison showed no statistical significance (P>0.05. The intra-group comparison and the inter-group comparison show that the difference in terms of changes of HR, MAP and SpO2 of patients in two groups before and after the anesthesia had no statistical significance (P>0.05.The awakening time, VAS score, postoperative vomiting times and the occurrence rate of respiratory depression of the observation group

  7. Screening for comorbid conditions in patients enrolled in the SODA registry: a 2-year observational analysis.

    Science.gov (United States)

    Woodmansee, Whitney W; Gordon, Murray B; Molitch, Mark E; Ioachimescu, Adriana G; Carver, Don W; Mirakhur, Beloo; Cox, David; Salvatori, Roberto

    2018-05-16

    This 2-year analysis assessed frequency of comorbidities and comorbidity screening in the Somatuline ® (lanreotide, LAN) Depot for Acromegaly (SODA) registry. Patient data collected included pituitary hormone deficiencies, sleep studies, echocardiograms, gallbladder sonographies, colonoscopies, and glycated hemoglobin (HbA1c) levels. Insulin-like growth factor-1 (IGF-1) and growth hormone levels in patients with (DM) and without (non-DM) diabetes mellitus were analyzed. There were 241 patients enrolled. Pituitary hormone deficiencies were reported more frequently at enrollment in male (56.9%) vs female patients (32.0%; p < 0.001). TSH deficiency was the most common endocrine deficiency (69.8%), followed by gonadotropin deficiency (62.3%). Screening tests reported at enrollment: sleep studies in 29.9% (79.2% had sleep apnea), echocardiogram in 46.1% (46.8% abnormal), gallbladder sonography in 18.7% (17.8% had gallstones), and colonoscopy in 48.1% (35.3% had polyps). Follow-up studies were reported less frequently at 1 and 2 years. HbA1c data were reported in 30.8% and 41.2% after 1 and 2 years. HbA1c levels were similar at 1 and 2 years of LAN therapy among DM and non-DM patients with available data. Fewer DM vs non-DM patients achieved IGF-1 below upper limit of normal at Month 24 (58.3% vs 80.6%; p = 0.033). Fewer than half of patients in SODA had screening results reported at enrollment for sleep apnea, cardiomyopathy, and colon polyps. Gallbladder imaging was reported in a minority of patients. Lower IGF-1 control rates were observed in DM vs non-DM patients at Month 24. These data suggest a need for better monitoring of comorbidities in US acromegaly patients.

  8. Colon Capsule Endoscopy: Where Are We and Where Are We Going

    Directory of Open Access Journals (Sweden)

    Yoo Min Han

    2016-09-01

    Full Text Available Colon capsule endoscopy (CCE is a noninvasive technique for diagnostic imaging of the colon. It does not require air inflation or sedation and allows minimally invasive and painless colonic evaluation. The role of CCE is rapidly evolving; for example, for colorectal screening (colorectal cancer [CRC] in average-risk patients, in patients with an incomplete colonoscopy, in patients refusing a conventional colonoscopy, and in patients with contraindications for conventional colonoscopy. In this paper, we comprehensively review the technical characteristics and procedure of CCE and compare CCE with conventional methods such as conventional colonoscopy or computed tomographic colonography. Future expansion of CCE in the area of CRC screening for the surveillance of polyps and adenomatous lesions and for assessment of inflammatory bowel disease is also discussed.

  9. Universal Versus Targeted Screening for Lynch Syndrome: Comparing Ascertainment and Costs Based on Clinical Experience.

    Science.gov (United States)

    Erten, Mujde Z; Fernandez, Luca P; Ng, Hank K; McKinnon, Wendy C; Heald, Brandie; Koliba, Christopher J; Greenblatt, Marc S

    2016-10-01

    Strategies to screen colorectal cancers (CRCs) for Lynch syndrome are evolving rapidly; the optimal strategy remains uncertain. We compared targeted versus universal screening of CRCs for Lynch syndrome. In 2010-2011, we employed targeted screening (age Lynch syndrome and estimated the 5-year costs of preventing CRC by colonoscopy screening, using a system dynamics model. Using targeted screening, 51/175 (29 %) cancers fit criteria and were tested by immunohistochemistry; 15/51 (29 %, or 8.6 % of all CRCs) showed suspicious loss of ≥1 mismatch repair protein. Germline mismatch repair gene mutations were found in 4/4 cases sequenced (11 suspected cases did not have germline testing). Using universal screening, 17/292 (5.8 %) screened cancers had abnormal immunohistochemistry suspicious for Lynch syndrome. Germline mismatch repair mutations were found in only 3/10 cases sequenced (7 suspected cases did not have germline testing). The mean cost to identify Lynch syndrome probands was ~$23,333/case for targeted screening and ~$175,916/case for universal screening at our institution. Estimated costs to identify and screen probands and relatives were: targeted, $9798/case and universal, $38,452/case. In real-world Lynch syndrome management, incomplete clinical follow-up was the major barrier to do genetic testing. Targeted screening costs 2- to 7.5-fold less than universal and rarely misses Lynch syndrome cases. Future changes in testing costs will likely change the optimal algorithm.

  10. Gender Identity Disparities in Cancer Screening Behaviors.

    Science.gov (United States)

    Tabaac, Ariella R; Sutter, Megan E; Wall, Catherine S J; Baker, Kellan E

    2018-03-01

    Transgender (trans) and gender-nonconforming adults have reported reduced access to health care because of discrimination and lack of knowledgeable care. This study aimed to contribute to the nascent cancer prevention literature among trans and gender-nonconforming individuals by ascertaining rates of breast, cervical, prostate, and colorectal cancer screening behaviors by gender identity. Publicly available de-identified data from the 2014-2016 Behavioral Risk Factor Surveillance System surveys were utilized to evaluate rates of cancer screenings by gender identity, while controlling for healthcare access, sociodemographics, and survey year. Analyses were conducted in 2017. Weighted chi-square tests identified significant differences in the proportion of cancer screening behaviors by gender identity among lifetime colorectal cancer screenings, Pap tests, prostate-specific antigen tests, discussing prostate-specific antigen test advantages/disadvantages with their healthcare provider, and up-to-date colorectal cancer screenings and Pap tests (pgender identity were fully explained by covariates, trans women had reduced odds of having up-to-date colorectal cancer screenings compared to cisgender (cis) men (AOR=0.20) and cis women (AOR=0.24), whereas trans men were more likely to ever receive a sigmoidoscopy/colonoscopy as compared to cis men (AOR=2.76) and cis women (AOR=2.65). Trans women were more likely than cis men to have up-to-date prostate-specific antigen tests (AOR=3.19). Finally, trans men and gender-nonconforming individuals had reduced odds of lifetime Pap tests versus cis women (AOR=0.14 and 0.08, respectively), and gender-nonconforming individuals had lower odds of discussing prostate-specific antigen tests than cis men (AOR=0.09; all pgender identity disparities in cancer screenings persist beyond known sociodemographic and healthcare factors. It is critical that gender identity questions are included in cancer and other health-related surveillance

  11. Colorectal cancer screening of immigrants to Italy. Figures from the 2013 National Survey.

    Science.gov (United States)

    Turrin, Anna; Zorzi, Manuel; Giorgi Rossi, Paolo; Senore, Carlo; Campari, Cinzia; Fedato, Chiara; Naldoni, Carlo; Anghinoni, Emanuela; Carrozzi, Giuliano; Sassoli De' Bianchi, Priscilla; Zappa, Marco

    2015-12-01

    Colorectal cancer screening programmes in Italy invite 50-69-year-old residents for a faecal immunochemical test every two years, regardless of their citizenship. The 2013 National Survey on Italian colorectal cancer screening programmes compared immigrants born in low- or middle-income countries with subjects who were born in Italy, by collecting aggregated data on compliance, faecal immunochemical test results, compliance with colonoscopy, detected lesions and stage at diagnosis separately for Italians and immigrants. Overall, 85 screening programmes invited 3,292,451 subjects, of whom 192,629 had been born abroad (5.9%). Compliance with invitation was lower in immigrants (34.3% vs. 51.3% in Italians), with pimmigrants but in the oldest of Italians. Immigrants showed a borderline excess of standardised faecal immunochemical test positivity rate at first screening (5.4% vs. 5.1% in Italians, p=0.05) and a significant excess at repeat screenings (4.8% vs. 4.4%, p=0.002). The detection rates for carcinoma and advanced adenomas were lower in immigrants than in Italians at first screening (respectively 1.34‰ vs. 1.62‰ and 8.41‰ vs. 9.25‰) - although the differences were not statistically significant - but not at repeat screening (respectively 1.06‰ vs. 0.98‰ and 6.90‰ vs. 6.79‰). Migrants showed a lower compliance with screening than Italians. The prevalence of neoplasia was lower at first screening and similar to the Italians' at repeat screenings. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Women patients' preference for women physicians is a barrier to colon cancer screening.

    Science.gov (United States)

    Menees, Stacy B; Inadomi, John M; Korsnes, Sheryl; Elta, Grace H

    2005-08-01

    The preference of women patients for women physicians has been shown in many specialties. Women patients awaiting a lower endoscopy have been shown to have a preference for women endoscopists. The reasons for this preference and the strength of this preference have not been studied in the primary care setting. A questionnaire was given to female patients who were waiting for primary care appointments at 4 offices. Patients reported sociodemographic characteristics, experiences with colorectal cancer (CRC), barriers to CRC screening, gender preference of their physician, the significance, and reasons for this preference. A total of 202 women patients aged 40 to 70 years (mean 53 years) completed the questionnaire. Of these patients, 43% preferred a woman endoscopist, and of these, 87% would be willing to wait >30 days for a woman endoscopist, and 14% would be willing to pay more for one. The most common reason (in 75%) for this gender preference was embarrassment. Univariate analysis revealed that gender of the primary care physician (PCP), younger patient age, current employment, and no previous history of colonoscopy were predictors of preference for a woman endoscopist. Of these variables, only female gender of the PCP (OR 2.84: 95% CI[1.49, 5.40]) and employment (OR 2.4: 95% CI[1.23, 4.67]) were positive predictors for a woman endoscopist preference by multivariable analysis; 5% stated that they would not undergo a colonoscopy unless guaranteed a woman endoscopist. The sole independent factor associated with adherence to screening was PCP recommendation (OR 2.93: 95% CI[1.63, 5.39]). Women patients frequently prefer a woman endoscopist, and this preference is reported as being strong enough to delay the procedure and to incur personal expense. It is an absolute barrier to endoscopy according to 5% in this subset of women surveyed. Interventions must be made in the primary care setting to address this issue and to increase the participation of women patients in

  13. Projected increased growth rate of anesthesia professional-delivered sedation for colonoscopy and EGD in the United States: 2009 to 2015.

    Science.gov (United States)

    Inadomi, John M; Gunnarsson, Candace L; Rizzo, John A; Fang, Hai

    2010-09-01

    Anesthesia professional-delivered sedation has become increasingly common when performing colonoscopy and EGD. To provide an estimate of anesthesia professional-participation rates in colonoscopy and EGD procedures and to examine rate changes over time and geographic variations for both procedures. Retrospective sample design. National survey data from i3 Innovus for the period 2003 to 2007 on the use rate of anesthesia professionals in both procedures. A sample of 3688 observations included 3-digit zip code-level information on anesthesia professional use rates. Data were linked to the Bureau of Health Professions' Area Resource File to control for sociodemographic factors and provider supply characteristics for anesthesia professional use rates. Multivariable regression analyses were performed to identify factors predicting the use rate of anesthesia professionals in these procedures and to forecast use rates for the years 2009 to 2015. For colonoscopy and EGD, anesthesia professional participation is projected to grow from 23.9% and 24.4% in 2007 to 53.4% and 52.9% by 2015, respectively. Average growth rates were highest in the northeast for colonoscopy (145.8%) and EGD (146.6%). Anesthesia professional use rates were significantly greater in areas having a higher percentage of older subjects (45 years and older), higher per capita income and lower unemployment rates, and higher per capita inpatient admissions and were significantly lower in areas having more per capita outpatient visits for both procedures. Nonexperimental retrospective sample study design. Database sample may not be nationally representative. Market area characteristics were used to control for socioeconomic and demographic factors. However, there may remain some important market factors that we were unable to control. Anesthesia professional-delivered sedation is projected to grow substantially for both procedures. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by

  14. Effect of Fee on Cervical Cancer Screening Attendance--ScreenFee, a Swedish Population-Based Randomised Trial.

    Science.gov (United States)

    Alfonzo, Emilia; Andersson Ellström, Agneta; Nemes, Szilard; Strander, Björn

    2016-01-01

    Attendance in the cervical cancer screening programme is one of the most important factors to lower the risk of contracting the disease. Attendance rates are often low in areas with low socioeconomic status. Charging a fee for screening might possibly decrease attendance in this population. Screening programme coverage is low in low socio-economic status areas in Gothenburg, Sweden, but has increased slightly after multiple interventions in recent years. For many years, women in the region have paid a fee for screening. We studied the effect of abolishing this fee in a trial emanating from the regular cervical cancer screening programme. Individually randomised controlled trial. All 3 124 women in three low-resource areas in Gothenburg, due for screening during the study period, were randomised to receive an offer of a free test or the standard invitation stating the regular fee of 100 SEK (≈11 €). The study was conducted during the first six months of 2013. Attendance was defined as a registered Pap smear within 90 days from the date the invitation was sent out. Attendance did not differ significantly between women who were charged and those offered free screening (RR 0.93; CI 0.85-1.02). No differences were found within the districts or as an effect of age, attendance after the most recent previous invitation or previous experience of smear taking. Abolishment of a modest screening fee in socially disadvantaged urban districts with low coverage, after previous multiple systematic interventions, does not increase attendance in the short term. Other interventions might be more important for increasing attendance in low socio-economic status areas. ClinicalTrials.gov NCT02378324.

  15. Comparison of One versus Two Fecal Immunochemical Tests in the Detection of Colorectal Neoplasia in a Population-Based Colorectal Cancer Screening Program

    Directory of Open Access Journals (Sweden)

    Sarvenaz Moosavi

    2016-01-01

    Full Text Available Objective. To determine the positive predictive value (PPV of two versus one abnormal FIT in the detection of colorectal neoplasia in a Canadian population. Methods. Three communities enrolled in a colorectal cancer (CRC screening pilot program from 01/2009 to 04/2013 using 2 FITs. Data collected included demographics, colonoscopy, pathology, and FIT results. Participants completed both FITs and had one positive FIT and colonoscopy. PPV of one versus two abnormal FITs was calculated using a weighted-generalized score statistic. A two-sided 5% significance level was used. Results. 1576 of 17,031 average-risk participants, 50–75 years old, had a positive FIT. Colonoscopy revealed 58 (3.7% cancers, 419 (31.6% high-risk polyps, and 374 (23.7% low-risk polyps as the most significant lesion. PPV of one versus two positive FITs for cancer, high-risk polyps, and any neoplasia were 1% versus 8%, 20% versus 40%, and 48% versus 67%, respectively (p value < 0.0001. When the first FIT was negative, the second positive FIT detected 7 CRCs and 98 high-risk polyps. Conclusions. PPV of two positive FITs is superior to one positive FIT for CRC and high-risk polyps. The added value of the second FIT was 12% of total CRCs and 23% of total high-risk polyps.

  16. Three-year colonoscopy surveillance after polypectomy in Korea: a Korean Association for the Study of Intestinal Diseases (KASID multicenter prospective study

    Directory of Open Access Journals (Sweden)

    Won Seok Choi

    2018-01-01

    Full Text Available Background/Aims: Colonoscopic surveillance is currently recommended after polypectomy owing to the risk of newly developed colonic neoplasia. However, few studies have investigated colonoscopy surveillance in Asia. This multicenter and prospective study was undertaken to assess the incidence of advanced adenoma based on baseline adenoma findings at 3 years after colonoscopic polypectomy. Methods: A total of 1,323 patients undergoing colonoscopic polypectomy were prospectively assigned to 3-year colonoscopy surveillance at 11 tertiary endoscopic centers. Relative risks for advanced adenoma after 3 years were calculated according to baseline adenoma characteristics. Results: Among 1,323 patients enrolled, 387 patients (29.3% were followed up, and the mean follow-up interval was 31.0±9.8 months. The percentage of patients with advanced adenoma on baseline colonoscopy was higher in the surveillance group compared to the non-surveillance group (34.4% vs. 25.7%. Advanced adenoma recurrence was observed in 17 patients (4.4% at follow-up. The risk of advanced adenoma recurrence was 2 times greater in patients with baseline advanced adenoma than in those with baseline non-advanced adenoma, though the difference was not statistically significant (6.8% [9/133] vs. 3.1% [8/254], P=0.09. Advanced adenoma recurrence was observed only in males and in subjects aged ≥50 years. In contrast, adenoma recurrence was observed in 187 patients (48.3% at follow-up. Male sex, older age (≥50 years, and multiple adenomas (≥3 at baseline were independent risk factors for adenoma recurrence. Conclusions: A colonoscopy surveillance interval of 3 years in patients with baseline advanced adenoma can be considered appropriate.

  17. A randomized, double-blind, phase 3 study of fospropofol disodium for sedation during colonoscopy.

    Science.gov (United States)

    Cohen, Lawrence B; Cattau, Edward; Goetsch, Allen; Shah, Atul; Weber, John R; Rex, Douglas K; Kline, Jacqueline M

    2010-01-01

    This double-blind, multicenter study evaluated the safety and efficacy of intravenous fospropofol (6.5 mg/kg vs. 2 mg/kg) for moderate sedation in patients undergoing colonoscopy. In all, 314 patients >or=18 years (American Society of Anesthesiologists PS1 to PS3) were randomized to receive fospropofol 2 mg/kg, fospropofol 6.5- mg/kg, or midazolam 0.02 mg/kg, after pretreatment with intravenous fentanyl 50 mcg. Supplemental doses of study medication were permitted to achieve a Modified Observer's Assessment of Alertness/Sedation scale score sedation success, recovery, memory retention, physician satisfaction, and safety. Sedation success was higher in the fospropofol 6.5 mg/kg versus 2 mg/kg group (87% vs. 26%; Pmemory retention (70% and 82% for the 6.5 mg/kg and 2 mg/kg groups, respectively) compared with 41% for the midazolam group. Mean physician satisfaction scores were higher in the fospropofol 6.5-mg/kg group (7.7) than the 2-mg/kg group (4.5), Psedation during colonoscopy and was associated with higher rates of sedation success, memory retention, and physician satisfaction than the fospropofol 2-mg/kg dose.

  18. Coordinate-invariant regularization

    International Nuclear Information System (INIS)

    Halpern, M.B.

    1987-01-01

    A general phase-space framework for coordinate-invariant regularization is given. The development is geometric, with all regularization contained in regularized DeWitt Superstructures on field deformations. Parallel development of invariant coordinate-space regularization is obtained by regularized functional integration of the momenta. As representative examples of the general formulation, the regularized general non-linear sigma model and regularized quantum gravity are discussed. copyright 1987 Academic Press, Inc

  19. An investigation of diverticular disease among black patients undergoing colonoscopy at Dr George Mukhari Academic Hospital, Pretoria, South Africa.

    Science.gov (United States)

    Vally, M; Koto, M Z; Govender, M

    2017-01-30

    Diverticular disease was previously thought to be non-existent in the black African population. Studies over the past four decades, however, have shown a steady increase in the prevalence of the disease. To report on the profile and current prevalence of diverticular disease in the black South African (SA) population at Dr George Mukhari Academic Hospital, Pretoria, SA. A retrospective descriptive study was performed in black SA patients who were diagnosed with diverticular disease by colonoscopy between 1 January and 31 December 2015. Of 348 patients who had undergone colonoscopies and who were eligible for inclusion in this study, 47 were diagnosed with diverticular disease - a prevalence of 13.50% (95% confidence interval 10.30 - 17.50). The greatest number of patients diagnosed were in their 7th and 8th decades, with an age range of 46 - 86 (mean 67) years. There was a female predominance of 57.45%. Lower gastrointestinal bleeding was the most common (65.96%) indication for colonoscopy. The left colon was most commonly involved (72.34%), followed by the right colon (55.31%). A substantial number of patients had pancolonic involvement (27.65%). This retrospective study suggests that there has been a considerable increase in the prevalence of diverticular disease among black South Africans, possibly owing to changes in dietary habits and socioeconomic status.

  20. An investigation of diverticular disease among black patients undergoing colonoscopy at Dr George Mukhari Academic Hospital, Pretoria, South Africa

    Directory of Open Access Journals (Sweden)

    M Vally

    2017-02-01

    Full Text Available Background. Diverticular disease was previously thought to be non-existent in the black African population. Studies over the past four decades, however, have shown a steady increase in the prevalence of the disease. Objective. To report on the profile and current prevalence of diverticular disease in the black South African (SA population at Dr George Mukhari Academic Hospital, Pretoria, SA. Methods. A retrospective descriptive study was performed in black SA patients who were diagnosed with diverticular disease by colonoscopy between 1 January and 31 December 2015. Results. Of 348 patients who had undergone colonoscopies and who were eligible for inclusion in this study, 47 were diagnosed with diverticular disease – a prevalence of 13.50% (95% confidence interval 10.30 - 17.50. The greatest number of patients diagnosed were in their 7th and 8th decades, with an age range of 46 - 86 (mean 67 years. There was a female predominance of 57.45%. Lower gastrointestinal bleeding was the most common (65.96% indication for colonoscopy. The left colon was most commonly involved (72.34%, followed by the right colon (55.31%. A substantial number of patients had pancolonic involvement (27.65%. Conclusion. This retrospective study suggests that there has been a considerable increase in the prevalence of diverticular disease among black South Africans, possibly owing to changes in dietary habits and socioeconomic status.

  1. [Massive trichuriasis in an adult diagnosed by colonoscopy].

    Science.gov (United States)

    Sapunar, J; Gil, L C; Gil, J G

    1999-01-01

    A case of massive trichuriasis in a 37-year-old female from a rural locality of the Metropolitan Region of Chile, with antecedents of alcoholism, chronic hepatic damage and portal cavernomatosis, is presented. Since 12 year ago she has had geophagia. In the last six months she has frequently presented liquid diarrhea, colic abdominal pains, tenesmus and sensation of abdominal distention. Clinical and laboratory tests confirmed her hepatic affection associated with a celiac disease with anemia and hypereosinophilia. Within a week diarrhea became worse and dysentery appeared. A colonoscopy revealed an impressive and massive trichuriasis. The patient was successfully treated with two cures of 200 mg tablets of mebendazole twice daily for three days with a week interval. After the first cure she evacuated a big amount of Tricuris trichiura, fecal evacuations became normal, geophagia disappeared and recovered 4 kg of body weight.

  2. Laterally Spreading Tumors of the Colon During High Resolution Colonoscopy with Narrow Band Imaging and Acetic Acid Chromoscopy

    Directory of Open Access Journals (Sweden)

    V.A. Yakovenko

    2015-02-01

    Materials and Methods. 1632 colonoscopy protocols were studied: 735 — by using video colonoscope Olympus CF-HQ190L and 897 — Olympus CF-150. Results and Discussion. In study group, adenoma detection rate was higher than in control one: 0.78 (571/735 vs. 0.47 (422/897, p < 0.00001; c2 = 157.9. Adenoma detection index was 3.6 times higher in study group than in control one: 2.9 (2,104/735 vs. 0.8 (708/897. Laterally spreading tumors were diagnosed 2.2 times more often in study group than in control one: 22 % (187/735 vs. 10 % (85/897, p < 0.00001; c2 = 53.6. Conclusions. High resolution colonoscopy with narrow band imaging and acetic acid chromoscopy has a high diagnostic value for detection of laterally spreading tumors of the colon.

  3. Performance of the colorectal cancer screening marker Sept9 is influenced by age, diabetes and arthritis: a nested case-control study

    DEFF Research Database (Denmark)

    Ørntoft, Mai-Britt Worm; Nielsen, Hans Jørgen; Ørntoft, Torben Falck

    2015-01-01

    Background Annually, colorectal cancer (CRC) is diagnosed in >1.4 million subjects worldwide and incidence is increasing. Much effort has therefore been focused on screening, which has proven to reduce cancer-related mortality. The Sept9 DNA-methylation assay is among the most well studied blood......-based screening markers. However, earlier reported performances may be misleading: the Sept9 test was recently examined in two screening based cohorts and yielded performances lower than expected. We hypothesize that comorbidities and/or demographic characteristics affect the results of the Sept9 test. Methods...... Using a retrospective nested case–control study design, we studied plasma from 150 cancer and 150 controls selected from a well-characterized cohort of 4698 subjects referred for diagnostic colonoscopy due to CRC-related symptoms. The cases and controls were matched on age and gender, and moreover cases...

  4. Radiological mass screening in The Netherlands

    International Nuclear Information System (INIS)

    Pater, J. de

    1987-01-01

    Shortly after the end of the Second World War radiological mass screening was introduced in the Netherlands to detect tuberculosis of the lungs. A secondary effect was that by the same procedure lung tumours could also be detected. However as tuberculosis became less common the need for regular X-ray screening declined. The question at this point was whether routine screening should nevertheless be continued for the early detection of lung cancer. The Health Council opposed this suggestion in 1974 as it was doubtful whether early detection would improve the prognosis

  5. [Screening for colorectal cancer: a cost benefit analysis on a health prevention programme at the Boehringer Ingelheim Company].

    Science.gov (United States)

    Schneider, M; Häck, H-J

    2011-05-01

    In Germany, approximately 70.000 people are diagnosed with colorectal cancer every year. With early diagnosis the recovery rates are over 90 % and early intervention can significantly reduce the costs of medical treatment as well as the economic losses from worker productivity. We here present the organisational procedure for bowel cancer screening and have weighed the costs against benefits to employees, the company and the healthcare system. The screening costs are compared with economic benefits. The target group for the study consisted of all 11.536 employees at the company's site in Germany. Volunteers were given a standardized questionnaire about the risk factors for colorectal cancers and an immunological fecal occult blood test (IFOBT). If risk factors for development of colorectal cancer were present or if the test result was positive, a colonoscopy was recommended in accordance with DGVS guidelines (German Society of Digestive and Metabolic diseases). A total of 4.287 employees (37.2 %) indicated an interest in undergoing screening; at the end of the period 3.958 complete datasets (2.296 men and 1.662 women, mean age 51.2 years) were available for evaluation. A colonoscopy was performed on 114 persons. Six cases of overt cancer were detected with three in the 36 - 50 age group and three in the 51 - 65 age group. Five of the six cases were stage T1 or T2. Adenomatous polyps were found and removed in 29 persons. The calculated cost benefit ratio was 1:2 for the company and 1:35 for the public health system. Using the example of colorectal screening, this study represents a cost benefit analysis of this preventative health measure in a company environment. The results show that even while taking into account the financial and personal commitment required, the cost benefit ratio is positive both for the company and for the healthcare system. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Risk assessment and clinical decision making for colorectal cancer screening.

    Science.gov (United States)

    Schroy, Paul C; Caron, Sarah E; Sherman, Bonnie J; Heeren, Timothy C; Battaglia, Tracy A

    2015-10-01

    Shared decision making (SDM) related to test preference has been advocated as a potentially effective strategy for increasing adherence to colorectal cancer (CRC) screening, yet primary care providers (PCPs) are often reluctant to comply with patient preferences if they differ from their own. Risk stratification advanced colorectal neoplasia (ACN) provides a rational strategy for reconciling these differences. To assess the importance of risk stratification in PCP decision making related to test preference for average-risk patients and receptivity to use of an electronic risk assessment tool for ACN to facilitate SDM. Mixed methods, including qualitative key informant interviews and a cross-sectional survey. PCPs at an urban, academic safety-net institution. Screening preferences, factors influencing patient recommendations and receptivity to use of a risk stratification tool. Nine PCPs participated in interviews and 57 completed the survey. Despite an overwhelming preference for colonoscopy by 95% of respondents, patient risk (67%) and patient preferences (63%) were more influential in their decision making than patient comorbidities (31%; P decision making, yet few providers considered risk factors other than age for average-risk patients. Providers were receptive to the use of a risk assessment tool for ACN when recommending an appropriate screening test for select patients. © 2013 John Wiley & Sons Ltd.

  7. Evaluation Of Cervical Cancer Screening Program At A Rural ...

    African Journals Online (AJOL)

    But the condition is preventable through regular screening of women those are 'at risk\\' for abnormal changes in the cervix and treating them who have positive results. Although screening facilities are ... Keywords: Cervical cancer, Pap smear test, knowledge, practice, programme coverage. East African Journal of Public ...

  8. Effect of Fee on Cervical Cancer Screening Attendance—ScreenFee, a Swedish Population-Based Randomised Trial

    Science.gov (United States)

    Alfonzo, Emilia; Andersson Ellström, Agneta; Nemes, Szilard; Strander, Björn

    2016-01-01

    Background Attendance in the cervical cancer screening programme is one of the most important factors to lower the risk of contracting the disease. Attendance rates are often low in areas with low socioeconomic status. Charging a fee for screening might possibly decrease attendance in this population. Screening programme coverage is low in low socio-economic status areas in Gothenburg, Sweden, but has increased slightly after multiple interventions in recent years. For many years, women in the region have paid a fee for screening. We studied the effect of abolishing this fee in a trial emanating from the regular cervical cancer screening programme. Method Individually randomised controlled trial. All 3 124 women in three low-resource areas in Gothenburg, due for screening during the study period, were randomised to receive an offer of a free test or the standard invitation stating the regular fee of 100 SEK (≈11 €). The study was conducted during the first six months of 2013. Attendance was defined as a registered Pap smear within 90 days from the date the invitation was sent out. Results Attendance did not differ significantly between women who were charged and those offered free screening (RR 0.93; CI 0.85–1.02). No differences were found within the districts or as an effect of age, attendance after the most recent previous invitation or previous experience of smear taking. Conclusion Abolishment of a modest screening fee in socially disadvantaged urban districts with low coverage, after previous multiple systematic interventions, does not increase attendance in the short term. Other interventions might be more important for increasing attendance in low socio-economic status areas. Trial Registration ClinicalTrials.gov NCT02378324 PMID:26986848

  9. Análise retrospectiva de 504 colonoscopias Retrospective analysis of 504 colonoscopies

    Directory of Open Access Journals (Sweden)

    Rodrigo Guimarães Oliveira

    2010-06-01

    , estando dentro dos padrões habituais.The authors retrospectively analyzed 504 outpatient undergoing colonoscopy, performed from June 2008 to May 2009, in the "Center for Medical Specialties" of Santa Casa de Belo Horizonte, by the Group of Coloproctology of Santa Casa de Belo Horizonte and School of Medical Sciences of Minas Gerais (CPG. The study deserve special highlights the analysis of gender, age, specialty of referring physicians, indications of colonoscopy, bowel preparation used, height achieved by colonoscopy and colonoscopic findings. Regarding gender, 67% (337 were women and 33% (167 men, and as to age, stood sixth (130 patients, 26% and seventh (113 patients, 22%. The examination was self-generated by the GCP in 79.56% (401 colonoscopies and the most common indications were low bleeding (76 cases, 13.0% and control patients undergoing surgical approach to colorectal cancer (70 cases; 12.0%. Bowel preparation was done with mannitol, lactulose and sodium picosulphate, according to the clinical status, allowing for 71% (359 cases of excellent results. Colonoscopy reached the cecum in 445 patients (88.0%, having reached the terminal ileum in 293 cases (58.0%. The main findings were polyps (163 cases, 28.0%, followed by normal findings (149 cases, 26.0% and diverticular disease of the colon (141 cases, 24.0%. Of the 151 polyps that had marked its size, 130 polyps were the largest diameter less than 10 mm (86.0%. Of 207 histopathological examinations performed, either in biopsies or in polyp resection, the polyp was the most common finding (163 cases, 78.8%, and among the 163 polyps resected the most common finding was the adenoma with low grade dysplasia (116 cases ; 71.2%. There were no complications. The data were compared with some published reports, all within the usual standards.

  10. Selection of regularization parameter for l1-regularized damage detection

    Science.gov (United States)

    Hou, Rongrong; Xia, Yong; Bao, Yuequan; Zhou, Xiaoqing

    2018-06-01

    The l1 regularization technique has been developed for structural health monitoring and damage detection through employing the sparsity condition of structural damage. The regularization parameter, which controls the trade-off between data fidelity and solution size of the regularization problem, exerts a crucial effect on the solution. However, the l1 regularization problem has no closed-form solution, and the regularization parameter is usually selected by experience. This study proposes two strategies of selecting the regularization parameter for the l1-regularized damage detection problem. The first method utilizes the residual and solution norms of the optimization problem and ensures that they are both small. The other method is based on the discrepancy principle, which requires that the variance of the discrepancy between the calculated and measured responses is close to the variance of the measurement noise. The two methods are applied to a cantilever beam and a three-story frame. A range of the regularization parameter, rather than one single value, can be determined. When the regularization parameter in this range is selected, the damage can be accurately identified even for multiple damage scenarios. This range also indicates the sensitivity degree of the damage identification problem to the regularization parameter.

  11. Willingness to take a screening test for colorectal cancer: a community-based survey in Malaysia.

    Science.gov (United States)

    Naing, Cho; Jun, Yip Kar; Yee, Wai Mun; Waqiyuddin, Syazana J D B T; Lui, Lau Chiew; Shaung, Ooi Yin; Haw, Fong Jenn

    2014-03-01

    The aims of the study were (i) to determine the knowledge and perceptions of colorectal cancer (CRC), (ii) to explore the willingness of the study population to take a screening test for CRC, and (iii) to identify factors affecting the willingness to take a screening test for CRC. A cross-sectional survey was carried out in a semiurban town in Malaysia using a pretested structured questionnaire. Descriptive statistics were determined for all important variables. A binary logistic regression model was introduced to identify independent predictors of the willingness to take a screening test. Factors influencing willingness were explored according to the constructs of the health belief model. Of the 256 respondents who had heard about CRC, the majority were aware of altered bowel habits (67.3%) or the presence of blood in stool or rectal bleeding (63.4%) as the warning symptoms. Although 38% of the respondents knew of colonoscopy as the screening test, 22% were not aware of any screening test for CRC. A majority (77.4%) showed willingness to take a screening test for CRC. In the multivariate analysis, 'having family or friends with history of CRC' and 'self-perceived risk' were the two significant variables for predicting the acceptance of CRC screening among the study population. Findings suggested that the respondents' knowledge of the CRC screening test was inadequate, albeit a high proportion expressed their intention to take screening tests. Health education on the CRC addressing available screening tests and the benefits of early screening for CRC should be scaled up.

  12. Informed consent in colonoscopy: A comparative analysis of 2 methods.

    Science.gov (United States)

    Sanguinetti, J M; Lotero Polesel, J C; Iriarte, S M; Ledesma, C; Canseco Fuentes, S E; Caro, L E

    2015-01-01

    The manner in which informed consent is obtained varies. The aim of this study is to evaluate the level of knowledge about colonoscopy and comparing 2 methods of obtaining informed consent. A comparative, cross-sectional, observational study was conducted on patients that underwent colonoscopy in a public hospital (Group A) and in a private hospital (Group B). Group A received information verbally from a physician, as well as in the form of printed material, and Group B only received printed material. A telephone survey was carried out one or 2 weeks later. The study included a total of 176 subjects (group A [n=55] and group B [n=121]). As regards education level, 69.88% (n=123) of the patients had completed university education, 23.29% (n= 41) secondary level, 5.68% (n=10) primary level, and the remaining subjects (n=2) had not completed any level of education. All (100%) of the subjects knew the characteristics of the procedure, and 99.43% were aware of its benefits. A total of 97.7% received information about complications, 93.7% named some of them, and 25% (n=44) remembered major complications. All the subjects received, read, and signed the informed consent statement before the study. There were no differences between the groups with respect to knowledge of the characteristics and benefits of the procedure, or the receipt and reading of the consent form. Group B responded better in relation to complications (P=.0027) and group A had a better recollection of the major complications (P<.0001). Group A had a higher number of affirmative answers (P<.0001). The combination of verbal and written information provides the patient with a more comprehensive level of knowledge about the procedure. Copyright © 2014 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.

  13. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme

    DEFF Research Database (Denmark)

    Enerly, Espen; Bonde, Jesper; Schee, Kristina

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance....... To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited...... alternative for increasing cervical cancer screening coverage in Norway....

  14. Five year colorectal cancer outcomes in a large negative CT colonography screening cohort

    Energy Technology Data Exchange (ETDEWEB)

    Kim, David H.; Pooler, B.D.; Pickhardt, Perry J. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Weiss, Jennifer M. [University of Wisconsin School of Medicine and Public Health, Section of Gastroenterology, Department of Internal Medicine, Madison, WI (United States)

    2012-07-15

    To assess the 5-year incidence of clinically presenting colorectal cancers following a negative CT colonography (CTC) screening examination, as few patient outcome data regarding a negative CTC screening result exist. Negative CTC screening patients (n = 1,050) in the University of Wisconsin Health system over a 14-month period were included. An electronic medical record (EMR) review was undertaken, encompassing provider, colonoscopy, imaging and histopathology reports. Incident colorectal cancers and other important GI tumours were recorded. Of the 1,050 cohort (mean [{+-}SD] age 56.9 {+-} 7.4 years), 39 (3.7%) patients were excluded owing to lack of follow-up within our system beyond the initial screening CTC. The remaining 1,011 patients were followed for an average of 4.73 {+-} 1.15 years. One incident colorectal adenocarcinoma represented a crude cancer incidence of 0.2 cancers per 1,000 patient years. EMR revealed 14 additional patients with clinically important GI tumours including: advanced adenomas (n = 11), appendiceal goblet cell carcinoid (n = 1), appendiceal mucinous adenoma (n = 1) and metastatic ileocolonic carcinoid (n = 1). All positive patients including the incident carcinoma are alive at the time of review. Clinically presenting colorectal adenocarcinoma is rare in the 5 years following negative screening CTC, suggesting that current strategies, including non-reporting of diminutive lesions, are appropriate. (orig.)

  15. Five year colorectal cancer outcomes in a large negative CT colonography screening cohort

    International Nuclear Information System (INIS)

    Kim, David H.; Pooler, B.D.; Pickhardt, Perry J.; Weiss, Jennifer M.

    2012-01-01

    To assess the 5-year incidence of clinically presenting colorectal cancers following a negative CT colonography (CTC) screening examination, as few patient outcome data regarding a negative CTC screening result exist. Negative CTC screening patients (n = 1,050) in the University of Wisconsin Health system over a 14-month period were included. An electronic medical record (EMR) review was undertaken, encompassing provider, colonoscopy, imaging and histopathology reports. Incident colorectal cancers and other important GI tumours were recorded. Of the 1,050 cohort (mean [±SD] age 56.9 ± 7.4 years), 39 (3.7%) patients were excluded owing to lack of follow-up within our system beyond the initial screening CTC. The remaining 1,011 patients were followed for an average of 4.73 ± 1.15 years. One incident colorectal adenocarcinoma represented a crude cancer incidence of 0.2 cancers per 1,000 patient years. EMR revealed 14 additional patients with clinically important GI tumours including: advanced adenomas (n = 11), appendiceal goblet cell carcinoid (n = 1), appendiceal mucinous adenoma (n = 1) and metastatic ileocolonic carcinoid (n = 1). All positive patients including the incident carcinoma are alive at the time of review. Clinically presenting colorectal adenocarcinoma is rare in the 5 years following negative screening CTC, suggesting that current strategies, including non-reporting of diminutive lesions, are appropriate. (orig.)

  16. Hallazgos colonoscópicos del estudio piloto de cribado de cáncer colorrectal realizado en Cataluña Colonoscopic findings from a pilot screening study for colorectal cancer in Catalonia

    Directory of Open Access Journals (Sweden)

    M. Navarro

    2008-06-01

    Full Text Available Objetivo: evaluar las lesiones detectadas en las dos rondas ya finalizadas del Programa Piloto de Cribado en Cáncer Colorrectal (CCR llevado a cabo en L'Hospitalet de Llobregat (Barcelona. Material y métodos: el programa de cribado de CCR se inició en el año 2000. La población, comprendida entre 50 y 69 años residentes en el área, fue invitada a participar a través de la determinación bienal de sangre oculta en heces mediante el test guaiaco y colonoscopia en los participantes con test positivo. Se realizó polipectomía de las lesiones detectadas o biopsias cuando no era posible la extirpación. Los pólipos se clasificaron según criterios de la Organización Mundial de la Salud. Resultados: se realizaron 442 colonoscopias de los 495 test positivos. En 213 individuos, se detectaron: 36 cánceres invasivos, 121 adenomas de alto riesgo, 29 adenomas de bajo riesgo y 27 pólipos hiperplásicos. En el 25,8% de los casos, el tamaño de los adenomas fue Objective: to evaluate lesions detected in two screening rounds performed in a pilot screening program for colorectal cancer in Catalonia, Spain. Material and methods: a colorectal cancer screening program was initiated in 2000. The target population included men and women aged 50-69 years. Screening consisted of biennial guaiac-based fecal occult blood testing (FOBT, and colonoscopy for participants with a positive FOBT. Any polyps found were removed, and biopsies were performed for any masses. Results: Colonoscopies were performed in 442 of 495 people with positive FOBT. In 213 (48.2%, 36 invasive cancers, 121 high-risk adenomas, 29 low-risk adenomas, and 27 hyperplastic polyps were diagnosed. Lesion size was smaller than 10 mm in 25.8% of cases. Most detected lesions (37.2% were located in the distal colon, followed by the proximal colon (5.7% and both locations (5.2%. Advanced neoplasm was significantly associated with male gender and distal location. The prevalence of advanced proximal

  17. Potential testing of reprocessing procedures by real-time polymerase chain reaction: A multicenter study of colonoscopy devices.

    Science.gov (United States)

    Valeriani, Federica; Agodi, Antonella; Casini, Beatrice; Cristina, Maria Luisa; D'Errico, Marcello Mario; Gianfranceschi, Gianluca; Liguori, Giorgio; Liguori, Renato; Mucci, Nicolina; Mura, Ida; Pasquarella, Cesira; Piana, Andrea; Sotgiu, Giovanni; Privitera, Gaetano; Protano, Carmela; Quattrocchi, Annalisa; Ripabelli, Giancarlo; Rossini, Angelo; Spagnolo, Anna Maria; Tamburro, Manuela; Tardivo, Stefano; Veronesi, Licia; Vitali, Matteo; Romano Spica, Vincenzo

    2018-02-01

    Reprocessing of endoscopes is key to preventing cross-infection after colonoscopy. Culture-based methods are recommended for monitoring, but alternative and rapid approaches are needed to improve surveillance and reduce turnover times. A molecular strategy based on detection of residual traces from gut microbiota was developed and tested using a multicenter survey. A simplified sampling and DNA extraction protocol using nylon-tipped flocked swabs was optimized. A multiplex real-time polymerase chain reaction (PCR) test was developed that targeted 6 bacteria genes that were amplified in 3 mixes. The method was validated by interlaboratory tests involving 5 reference laboratories. Colonoscopy devices (n = 111) were sampled in 10 Italian hospitals. Culture-based microbiology and metagenomic tests were performed to verify PCR data. The sampling method was easily applied in all 10 endoscopy units and the optimized DNA extraction and amplification protocol was successfully performed by all of the involved laboratories. This PCR-based method allowed identification of both contaminated (n = 59) and fully reprocessed endoscopes (n = 52) with high sensibility (98%) and specificity (98%), within 3-4 hours, in contrast to the 24-72 hours needed for a classic microbiology test. Results were confirmed by next-generation sequencing and classic microbiology. A novel approach for monitoring reprocessing of colonoscopy devices was developed and successfully applied in a multicenter survey. The general principle of tracing biological fluids through microflora DNA amplification was successfully applied and may represent a promising approach for hospital hygiene. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Lav risiko for komplikationer ved screeningskoloskopi

    DEFF Research Database (Denmark)

    Thamsborg, Lise Laurberg Holst; Andersen, Ole; Fischer, Thea Kølsen

    2013-01-01

    In 2014, screening for colorectal cancer is scheduled to be introduced in Denmark using immunochemical test for blood in faeces (iFOBT). Positive tests are followed by colonoscopy. This review evaluates the risk of perforation, haemorrhage and death associated with screening colonoscopy based...... on selected recent publications. The risk of perforation and haemorrhage was reported to be 0.01% and 0.02% respectively. No deaths were reported. The studies vary in design and demographic characteristics why the findings are relevant regarding the planned national screening programme....

  19. Urinary excretion of polyethylene glycol 3350 during colonoscopy preparation

    DEFF Research Database (Denmark)

    Rothfuss, K. S.; Bode, J.C.; Stange, E.F.

    2006-01-01

    . In patients with inflammatory bowel disease (IBD), intestinal permeability and PEG absorption were previously reported to be higher than in normal subjects. In the current study, we investigated the absorption of PEG 3350 in patients undergoing routine gut lavage. METHODS AND RESULTS: Urine specimens were...... collected for 8 hours in 24 patients undergoing bowel cleansing with PEG 3350 for colonoscopy. The urinary excretion of PEG 3350, measured by size exclusion chromatography, ranged between 0.01 and 0.51 % of the ingested amount, corresponding to 5.8 and 896 mg in absolute amounts, respectively. Mean PEG...... that intestinal absorption of PEG 3350 is higher than previously assumed and underlies a strong inter-individual variation. Inflammatory changes of the intestine do not necessarily lead to a significantly higher permeability of PEG....

  20. The association between state mandates of colorectal cancer screening coverage and colorectal cancer screening utilization among US adults aged 50 to 64 years with health insurance

    Directory of Open Access Journals (Sweden)

    Virgo Katherine

    2011-01-01

    Full Text Available Abstract Background Several states in the US have passed laws mandating coverage of colorectal cancer (CRC screening tests by health insurance plans. The impact of these state mandates on the use of colorectal cancer screening has not been evaluated among an age-eligible target population with access to care (i.e., health care insurance coverage. Methods We collected information on state mandates implemented by December 31, 2008 and used data on insured adults aged 50 and 64 years from the Behavioral Risk Factor Surveillance System between 2002 and 2008 to classify individual-level exposure to state mandates for at least 1 year. Multivariate logistic regression models (with state- and year- fixed effects, and patient demographic and socioeconomic characteristics were used to estimate the effect of state mandates on recent endoscopy screening (either flexible sigmoidoscopy or colonoscopy during the past year. Results From 1999-2008, twenty-two states in the US, including the District of Columbia passed comprehensive laws requiring health insurance coverage of CRC screening including endoscopy tests. Residence in states with CRC screening coverage mandates in place for at least 1 year was associated with a 1.4 percentage point increase in the probability of utilization of recent endoscopy (i.e., 17.5% screening rates in those with mandates versus 16.1% in those without, Adjusted OR = 1.10, 95% CI: 1.02 - 1.20, p = 0.02. Conclusions The findings suggest a positive, albeit small, impact of state mandates on the use of recent CRC screening endoscopy among the target eligible population with health insurance. However, more research is needed to evaluate potential effects of mandates across health insurance types while including controls for other system-level factors (e.g. endoscopy and primary care capacity. National health insurance reform should strive towards a system that expands access to recommended CRC screening tests.

  1. [Findings from Total Colonoscopy in Obstructive Colorectal Cancer Patients Who Underwent Stent Placement as a Bridge to Surgery(BTS)].

    Science.gov (United States)

    Maruo, Hirotoshi; Tsuyuki, Hajime; Kojima, Tadahiro; Koreyasu, Ryohei; Nakamura, Koichi; Higashi, Yukihiro; Shoji, Tsuyoshi; Yamazaki, Masanori; Nishiyama, Raisuke; Ito, Tatsuhiro; Koike, Kota; Ikeda, Takashi; Takayanagi, Yasuhiro; Kubota, Hiroyuki

    2017-11-01

    We clinically investigated 34 patients with obstructive colorectal cancer who underwent placement of a colonic stent as a bridge to surgery(BTS), focusing on endoscopic findings after stent placement.Twenty -nine patients(85.3%)underwent colonoscopy after stent placement, and the entire large intestine could be observed in 28(96.6%).Coexisting lesions were observed in 22(78.6%)of these 28 patients.The lesions comprised adenomatous polyps in 17 patients(60.7%), synchronous colon cancers in 5 patients(17.9%), and obstructive colitis in 3 patients(10.7%), with some overlapping cases.All patients with multiple cancers underwent one-stage surgery, and all lesions were excised at the same time.Colonoscopy after colonic stent placement is important for preoperative diagnosis of coexisting lesions and planning the extent of resection. These considerations support the utility of colonic stenting for BTS.

  2. Colonoscopia: morbidade negligenciada Colonoscopy: neglected morbidity

    Directory of Open Access Journals (Sweden)

    Fernanda Bellotti Formiga

    2009-09-01

    Full Text Available OBJETIVO: Avaliar fatores de risco que determinam morbidade ao exame de colonoscopia. MÉTODOS: No período de março a junho de 2009 foram analisados prospectivamente 170 pacientes submetidos a exame colonoscópico. Fatores de risco como idade, sexo, indicação, exame ambulatorial/internado, efeitos adversos e qualidade do preparo intestinal, procedimento endoscópico, diagnóstico e intercorrência peri-procedimento foram relacionados. RESULTADOS: A média de idade da amostra foi 60,16 ± 14,69 anos, com predominância do sexo feminino. A indicação mais prevalente do exame foi seguimento pós-operatório. Três exames foram inconclusivos por mau preparo. Do restante, 36,53% foram normais e a maioria dos alterados apresentou pólipos, adenomatosos predominantemente. Quanto as comorbidades, 48,82% dos pacientes possuíam alguma comorbidade, sendo Hipertensão Arterial Sistêmica a mais prevalente. Apenas 22,94% dos pacientes apresentaram algum efeito adverso ao preparo. O preparo foi limpo em 65,88% dos exames, mostrando significância quando comparado a morbidade. Outro fator de significância estatística foi a realização de procedimentos (44,7% dos exames, sendo a maioria polipectomias. A morbidade chegou a 16,47%, sendo a desidratação a mais prevalente. Não houve mortalidade. CONCLUSÃO: A qualidade do preparo intestinal e a realização de procedimento endoscópico são fatores diretamente relacionados a morbidade do exame de colonoscopia.OBJECTIVE: The objective of this study is to analyze risks factors of morbidity on colonoscopy. METHOD: From March to June of 2009, 170 patients were examined and analyzed prospectively. Risks factors as age, sex, indication of exam, ambulatory or hospital exam, adverse events and quality of intestinal preparation, endoscopic procedure, diagnoses and incident before, during or after procedure were analyzed. RESULTS: The average age was 60,16±14,69 years old, with majority of female. The prevalent

  3. Individual differences in aversion to ambiguity regarding medical tests and treatments: association with cancer screening cognitions.

    Science.gov (United States)

    Han, Paul K J; Williams, Andrew E; Haskins, Amy; Gutheil, Caitlin; Lucas, F Lee; Klein, William M P; Mazor, Kathleen M

    2014-12-01

    Aversion to "ambiguity"-uncertainty about the reliability, credibility, or adequacy of information-about medical tests and treatments is an important psychological response that varies among individuals, but little is known about its nature and extent. The purpose of this study was to examine how individual-level ambiguity aversion relates to important health cognitions related to different cancer screening tests. A survey of 1,074 adults, ages 40 to 70 years, was conducted in four integrated U.S. healthcare systems. The Ambiguity Aversion in Medicine (AA-Med) scale, a measure of individual differences in aversion to ambiguity (AA) about medical tests and treatments, was administered along with measures of several cancer screening-related cognitions: perceived benefits and harms of colonoscopy, mammography, and PSA screening, and ambivalence and future intentions regarding these tests. Multivariable analyses were conducted to assess the associations between AA-Med scores and cancer screening cognitions. Individual-level AA as assessed by the AA-Med scale was significantly associated (P ambiguity. Individual-level AA constitutes a measurable, wide-ranging cognitive bias against medical intervention, and more research is needed to elucidate its mechanisms and effects. ©2014 American Association for Cancer Research.

  4. Budget-impact model for colonoscopy cost calculation and comparison between 2 litre PEG+ASC and sodium picosulphate with magnesium citrate or sodium phosphate oral bowel cleansing agents.

    Science.gov (United States)

    Gruss, H-J; Cockett, A; Leicester, R J

    2012-01-01

    With the availability of several bowel cleansing agents, physicians and hospitals performing colonoscopies will often base their choice of cleansing agent purely on acquisition cost. Therefore, an easy to use budget impact model has been developed and established as a tool to compare total colon preparation costs between different established bowel cleansing agents. The model was programmed in Excel and designed as a questionnaire evaluating information on treatment costs for a range of established bowel cleansing products. The sum of costs is based on National Health Service reference costs for bowel cleansing products. Estimations are made for savings achievable when using a 2-litre polyethylene glycol with ascorbate components solution (PEG+ASC) in place of other bowel cleansing solutions. Test data were entered into the model to confirm validity and sensitivity. The model was then applied to a set of audit cost data from a major hospital colonoscopy unit in the UK. Descriptive analysis of the test data showed that the main cost drivers in the colonoscopy process are the procedure costs and costs for bed days rather than drug acquisition costs, irrespective of the cleansing agent. Audit data from a colonoscopy unit in the UK confirmed the finding with a saving of £107,000 per year in favour of PEG+ASC when compared to sodium picosulphate with magnesium citrate solution (NaPic+MgCit). For every patient group the model calculated overall cost savings. This was irrespective of the higher drug expenditure associated with the use of PEG+ASC for bowel preparation. Savings were mainly realized through reduced costs for repeat colonoscopy procedures and associated costs, such as inpatient length of stay. The budget impact model demonstrated that the primary cost driver was the procedure cost for colonoscopy. Savings can be realized through the use of PEG+ASC despite higher drug acquisition costs relative to the comparator products. From a global hospital funding

  5. Dreaming and recall during sedation for colonoscopy.

    Science.gov (United States)

    Stait, M L; Leslie, K; Bailey, R

    2008-09-01

    Dreaming is reported by one in five patients who are interviewed on emergence from general anaesthesia, but the incidence, predictors and consequences of dreaming during procedural sedation are not known. In this prospective observational study, 200 patients presenting for elective colonoscopy under intravenous sedation were interviewed on emergence to determine the incidences of dreaming and recall. Sedation technique was left to the discretion of the anaesthetist. The incidence of dreaming was 25.5%. Patients reporting dreaming were younger than those who did not report dreaming. Doses of midazolam and fentanyl were similar between dreamers and non-dreamers, however propofol doses were higher in patients who reported dreams than those who did not. Patients reported short, simple dreams about everyday life--no dream suggested near-miss recall of the procedure. Frank recall of the procedure was reported by 4% of the patients, which was consistent with propofol doses commensurate with light general anaesthesia. The only significant predictor of recall was lower propofol dose. Satisfaction with care was generally high, however dreamers were more satisfied with their care than non-dreamers.

  6. Near infrared reactance for the estimation of body fatness in regularly exercising individuals.

    Science.gov (United States)

    Evans, J; Lambert, M I; Micklesfield, L K; Goedecke, J H; Jennings, C L; Savides, L; Claassen, A; Lambert, E V

    2013-07-01

    Near infrared reactance (NIR) is used to measure body fat percentage (BF%), but there is little data on its use in non-obese, regularly exercising individuals. Therefore, this study aimed to examine the limits of agreement between NIR compared to dual x-ray absorptiometry (DXA) for the measurement of BF% in 2 cohorts of regularly exercising individuals. BF% was measured using DXA and NIR in a regular exercising (≥3 sessions/week), healthy active cohort (HA; n=57), and in a regularly exercising and resistance trained (≥2 sessions/week) cohort (RT; n=59). The RT cohort had lower BF% than the HA cohort (15.3±5.5% and 25.8±7.1%, Pexercising individuals. However, the rather broad LOA of NIR need to be considered when using NIR to screen for overweight and obesity, or measure and track changes in body composition. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Do health behaviours change after colonoscopy? A prospective cohort study on diet, alcohol, physical activity and smoking among patients and their partners.

    Science.gov (United States)

    Hubbard, Gill; Brown, Alistair; Campbell, Anna; Campbell, Neil; Diament, Bob; Fielding, Shona; Forbat, Liz; Masson, Lindsey F; O'Carroll, Ronan; Stein, Kevin; Morrison, David S

    2014-01-14

    To describe diet, alcohol, physical activity and tobacco use prospectively, that is, before and 10 months after colonoscopy for patients and their partners. Prospective cohort study of health behaviour change in patients and partners. Comparison groups are patients receiving a normal result notification (NRN) versus patients receiving an abnormal result notification (ARN). Patients and partners (controls) are also compared. 5 Scottish hospitals. Of 5798 colonoscopy registrations, 2577 (44%) patients met the eligibility criteria of whom 565 (22%) were recruited; 460 partners were also recruited. International Physical Activity Questionnaire, Scottish Collaborative Group Food Frequency Questionnaire (includes alcohol), smoking status, sociodemographic characteristics, body mass index, medical conditions, colonoscopy result, Multidimensional Health Locus of Control Scale, behaviour-specific self-efficacy scales. 57% of patients were men, with a mean age of 60.8 years (SE 0.5) and 43% were from more affluent areas. 72% (n=387) of patients received an ARN and 28% (n=149) received an NRN. Response rate of the second questionnaire was 68.9%. Overall, 27% of patients consumed <5 measures of fruit and vegetables/day, 20% exceeded alcohol limits, 50% had low levels of physical activity and 21% were obese. At 10-month follow-up, a 5% reduction in excessive alcohol consumption and an 8% increase in low levels of physical activity were observed among patients; no significant changes occurred in partners. Baseline high alcohol consumption and low physical activity were the strongest predictors of these behaviours at follow-up. Low alcohol self-efficacy and increasing age were associated with poorer health-related behaviours at follow-up for alcohol consumption and physical activity, respectively. Colonoscopy is associated with marginal beneficial changes in some behaviours but not others. Further work is needed to explore how services can optimise increases in beneficial

  8. Application of laser-induced autofluorescence spectra detection in human colorectal cancer screening

    Science.gov (United States)

    Fu, Sheng; Chia, Teck-Chee; Kwek, Leong Chuan; Diong, Cheong Hoong; Tang, Choong Leong; Choen, Francis S.; Krishnan, S. M.

    2003-10-01

    We investigated 48 normal patients and 25 diseased patients using our laser-induced autofluorescence spectra detection system during their regular colonoscopy. The colon and rectum mucosa autofluorescence were excited by 405 nm continue wavelength laser. We observed that cancer or diseased colorectal mucosa, their autofluorescence spectra are significantly different from normal area. The autofluorescence spectra intensity at about 500 nm was been used for our intensity ratio characteristics intensity for our diagnostic algorithm. The intensity ratios of RI-680/I-500 and RI-630/I-500 were performed to identify the detection area. From experimental result we concluded that both intensity ratios of RI-680/I-500 and RI-630/I-500 as guidelines can detect cancerous and polyps disease completely. Our investigation provided some useful insight for laser induced autofluorescence spectra as a diagnosis technique for clinical application.

  9. [Faecal occult blood test for colorectal cancer screening: high quality for a good price].

    Science.gov (United States)

    van Veldhuizen, Harriët; Bonfrer, J M G Hans; Kuipers, Ernst J

    2013-01-01

    The Dutch National Institute for Public Health and the Environment (RIVM) awarded the immunochemical faecal occult blood test (IFOBT) to FOB Gold of Sentinel following a European call for tenders. The contract-awarding procedure included the application of quality knock-out criteria, which were met by two suppliers. The decisive factor was the best price/quality ratio. A recent review indicated that, at present, no single IFOBT is better than any other. The decision to opt for a test manufactured by a different supplier than was used in the previous screening pilots made it necessary to re-determine the cut-off value. This value has now been set (88 ng/ml) and is confirmed by a laboratory test. Colonoscopy-related capacity planning, as well as its diagnostic yield, depends on numerous factors; therefore, the RIVM is currently monitoring the referral percentage and number of adenomas detected and is collaborating on quality terms. Any necessary adjustments are to be made during the introduction of the screening test.

  10. Colonic locomotion

    NARCIS (Netherlands)

    Dodou, D.

    2006-01-01

    The most effective screening method for colonic cancer is colonoscopy. However, colonoscopy cannot be easily embraced by the population because of the related pain intensity. Robotic devices that pull themselves forward through the colon are a possible alternative. The main challenge for such

  11. Computerized tests to evaluate recovery of cognitive function after deep sedation with propofol and remifentanil for colonoscopy.

    Science.gov (United States)

    Borrat, Xavier; Ubre, Marta; Risco, Raquel; Gambús, Pedro L; Pedroso, Angela; Iglesias, Aina; Fernandez-Esparrach, Gloria; Ginés, Àngels; Balust, Jaume; Martínez-Palli, Graciela

    2018-03-27

    The use of sedation for diagnostic procedures including gastrointestinal endoscopy is rapidly growing. Recovery of cognitive function after sedation is important because it would be important for most patients to resume safe, normal life soon after the procedure. Computerized tests have shown being accurate descriptors of cognitive function. The purpose of the present study was to evaluate the time course of cognitive function recovery after sedation with propofol and remifentanil. A prospective observational double blind clinical study conducted in 34 young healthy adults undergoing elective outpatient colonoscopy under sedation with the combination of propofol and remifentanil using a target controlled infusion system. Cognitive function was measured using a validated battery of computerized cognitive tests (Cogstate™, Melbourne, Australia) at different predefined times: prior to starting sedation (Tbaseline), and then 10 min (T10), 40 min (T40) and 120 min (T120) after the end of colonoscopy. Tests included the assessment of psychomotor function, attention, visual memory and working memory. All colonoscopies were completed (median time: 26 min) without significant adverse events. Patients received a median total dose of propofol and remifentanil of 149 mg and 98 µg, respectively. Psychomotor function and attention declined at T10 but were back to baseline values at T40 for all patients. The magnitude of psychomotor task reduction was large (d = 0.81) however 100% of patients were recovered at T40. Memory related tasks were not affected 10 min after ending sedation. Cognitive impairment in attention and psychomotor function after propofol and remifentanil sedation was significant and large and could be easily detected by computerized cognitive tests. Even though, patients were fully recovered 40 min after ending the procedure. From a cognitive recovery point of view, larger studies should be undertaken to propose adequate criteria for discharge

  12. Diagnosis of Acute Appendicitis by Endoscopic Retrograde Appendicitis Therapy (ERAT): Combination of Colonoscopy and Endoscopic Retrograde Appendicography.

    Science.gov (United States)

    Li, Yingchao; Mi, Chen; Li, Weizhi; She, Junjun

    2016-11-01

    Acute appendicitis is the most common abdominal emergency, but the diagnosis of appendicitis remains a challenge. Endoscopic retrograde appendicitis therapy (ERAT) is a new and minimally invasive procedure for the diagnosis and treatment of acute appendicitis. To investigate the diagnostic value of ERAT for acute appendicitis by the combination of colonoscopy and endoscopic retrograde appendicography (ERA). Twenty-one patients with the diagnosis of suspected uncomplicated acute appendicitis who underwent ERAT between November 2014 and January 2015 were included in this study. The main outcomes, imaging findings of acute appendicitis including colonoscopic direct-vision imaging and fluoroscopic ERA imaging, were retrospectively reviewed. Secondary outcomes included mean operative time, mean hospital stay, rate of complication, rate of appendectomy during follow-up period, and other clinical data. The diagnosis of acute appendicitis was established in 20 patients by positive ERA (5 patients) or colonoscopy (1 patient) alone or both (14 patients). The main colonoscopic imaging findings included mucosal inflammation (15/20, 75 %), appendicoliths (14/20, 70 %), and maturation (5/20, 25 %). The key points of ERA for diagnosing acute appendicitis included radiographic changes of appendix (17/20, 85 %), intraluminal appendicoliths (14/20, 70 %), and perforation (1/20, 5 %). Mean operative time of ERAT was 49.7 min, and mean hospital stay was 3.3 days. No patient converted to emergency appendectomy. Perforation occurred in one patient after appendicoliths removal was not severe and did not require invasive procedures. During at least 1-year follow-up period, only one patient underwent laparoscopic appendectomy. ERAT is a valuable procedure of choice providing a precise yield of diagnostic information for patients with suspected acute appendicitis by combination of colonoscopy and ERA.

  13. Detection rate and predictive factors of sessile serrated polyps in an organised colorectal cancer screening programme with immunochemical faecal occult blood test: the EQuIPE study (Evaluating Quality Indicators of the Performance of Endoscopy).

    Science.gov (United States)

    Zorzi, Manuel; Senore, Carlo; Da Re, Filippo; Barca, Alessandra; Bonelli, Luigina Ada; Cannizzaro, Renato; de Pretis, Giovanni; Di Furia, Lucia; Di Giulio, Emilio; Mantellini, Paola; Naldoni, Carlo; Sassatelli, Romano; Rex, Douglas K; Zappa, Marco; Hassan, Cesare

    2017-07-01

    To assess detection rate and predictive factors of sessile serrated polyps (SSPs) in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). Data from a case series of colonoscopies of FIT-positive subjects were provided by 44 Italian CRC screening programmes. Data on screening history, endoscopic procedure and histology results, and additional information on the endoscopy centre and the endoscopists were collected, including the age-standardised and sex-standardised adenoma detection rate (ADR) of the individual endoscopists. The SSP detection rate (SSP-DR) was assessed for the study population. To identify SSP-predictive factors, multilevel analyses were performed according to patient/centre/endoscopist characteristics. We analysed 72 021 colonoscopies, of which 1295 presented with at least one SSP (SSP-DR 1.8%; 95% CI 1.7% to 1.9%). At the per-patient level, SSP-DR was associated with males (OR 1.35; 95% CI 1.17 to 1.54) and caecal intubation (OR 3.75; 95% CI 2.22 to 6.34), but not with the FIT round. The presence of at least one advanced adenoma was more frequent among subjects with SSPs than those without (OR 2.08; 95% CI 1.86 to 2.33). At the per-endoscopist level, SSP-DR was associated with ADR (third vs first ADR quartile: OR 1.55; 95% CI 1.03 to 2.35; fourth vs first quartile: OR 1.89; 95% CI 1.24 to 2.90). The low prevalence of SSPs and the lack of association with the FIT round argue against SSP as a suitable target for FIT-based organised programmes. Strict association of SSP-DR with the key colonoscopy quality indicators, namely caecal intubation rate and high ADR further marginalises the need for SSP-specific quality indicators in FIT-based programmes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Gastric emptying evaluation by ultrasound prior colonoscopy: An easy tool following bowel preparation

    Science.gov (United States)

    Coriat, Romain; Polin, Vanessa; Oudjit, Ammar; Henri, Franck; Dhooge, Marion; Leblanc, Sarah; Delchambre, Chantal; Esch, Anouk; Tabouret, Tessa; Barret, Maximilien; Prat, Frédéric; Chaussade, Stanislas

    2014-01-01

    AIM: To investigate the gastric emptying after bowel preparation to allow general anaesthesia. METHODS: A prospective, non-comparative, and non-randomized trial was performed and registered on Eudra CT database (2011-002953-80) and on www.trial.gov (NCT01398098). All patients had a validated indication for colonoscopy and a preparation using sodium phosphate (NaP) tablets. The day of the procedure, patients took 4 tablets with 250 mL of water every 15 min, three times. The gastric volume was estimated every 15 min from computed antral surfaces and weight according to the formula of Perlas et al (Anesthesiology, 2009). Colonoscopy was performed within the 6 h following the last intake. RESULTS: Thirty patients were prospectively included in the study from November 2011 to May 2012. The maximum volume of the antrum was 212 mL, achieved 15 min after the last intake. 24%, 67% and 92% of subjects had an antral volume below 20 mL at 60, 120 and 150 min, respectively. 81% of patients had a Boston score equal to 2 or 3 in each colonic segment. No adverse events leading to treatment discontinuation were reported. CONCLUSION: Gastric volume evaluation appeared to be a simple and reliable method for the assessment of gastric emptying. Data allow considering the NaP tablets bowel preparation in the morning of the procedure and confirming that gastric emptying is achieved after two hours, allowing general anaesthesia. PMID:25309090

  15. Colonoscopy is mandatory after Streptococcus bovis endocarditis: a lesson still not learned. Case report

    Directory of Open Access Journals (Sweden)

    Cavazzi Emma

    2008-05-01

    Full Text Available Abstract Background Even though the relationship between certain bacterial infections and neoplastic lesions of the colon is well-recognized, this knowledge has not been sufficiently translated into routine practice yet. Case presentation We describe the case of a 51-year-old man who was admitted to our Surgical Department due to rectal bleeding and abdominal pain. Preoperative colonoscopy, staging exams and subsequent surgery demonstrated a stenotic adenocarcinoma of the sigmoid colon, invading the left urinary tract and the homolateral bladder wall, with regional lymph nodes involvement and massive bilobar liver metastases (T4N1M1. After Hartmann's rectosigmoidectomy and despite systemic chemotherapy, a rapid progression occurred and the patient survived for only 5 months after diagnosis. Five years before detecting this advanced colonic cancer, the patient underwent aortic valve replacement due to a severe Streptococcus bovis endocarditis. Subsequent to this infection he never underwent a colonoscopy until overt intestinal symptoms appeared. Conclusion As this case illustrates, in the unusual setting of a Streptococcus bovis infection, it is necessary to timely and carefully rule out occult colon cancer and other malignancies during hospitalization and, if a tumor is not found, to schedule endoscopic follow-up. Rigorous application of these recommendations in the case described would have likely led to an earlier diagnosis of cancer and maybe saved the patient's life.

  16. Bowel preparation for pediatric colonoscopy: report of the NASPGHAN endoscopy and procedures committee.

    Science.gov (United States)

    Pall, Harpreet; Zacur, George M; Kramer, Robert E; Lirio, Richard A; Manfredi, Michael; Shah, Manoj; Stephen, Thomas C; Tucker, Neil; Gibbons, Troy E; Sahn, Benjamin; McOmber, Mark; Friedlander, Joel; Quiros, J A; Fishman, Douglas S; Mamula, Petar

    2014-09-01

    Pediatric bowel preparation protocols used before colonoscopy vary greatly, with no identified standard practice. The present clinical report reviews the evidence for several bowel preparations in children and reports on their use among North American Society for Pediatric Gastroenterology, Hepatology, and Nutrition members. Publications in the pediatric literature for bowel preparation regimens are described, including mechanisms of action, efficacy and ease of use, and pediatric studies. A survey distributed to pediatric gastroenterology programs across the country reviews present national practice, and cleanout recommendations are provided. Finally, further areas for research are identified.

  17. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... commonly known, virtual colonoscopy. Virtual colonoscopy is a diagnostic imaging test that is used to screen the large intestine or colon for cancer and growths called polyps. This procedure uses low-dose CT or CAT scanning ... Disorders Video: The Basketball Game: An ...

  18. A feasibility study on laxative-free bowel preparation for virtual colonoscopy

    Science.gov (United States)

    Liang, Zhengrong; Chen, Dongqing; Wax, Mark; Lakare, Sarang; Li, Lihong; Anderson, Joseph; Kaufman, Arie; Harrington, Donald

    2005-04-01

    Objective: To investigate the feasibility of laxative-free bowel preparation to relieve the patient stress in colon cleansing for virtual colonoscopy. Materials and Methods: Three different bowel-preparation protocols were investigated by 60 study cases from 35 healthy male volunteers. All the protocols utilize low-residue diet for two days and differ in diet for the third day - the day just prior to image acquisition in the fourth day morning. Protocol Diet-1 utilizes fluid or liquid diet in the third day, Diet-2 utilizes a food kit, and Diet-3 remains the low-residue diet. Oral contrast of barium sulfate (2.1%, 250 ml) was added respectively to the dinner in the second day and the three meals in the third day. Two doses of MD-Gastroview (60 ml) were ingested each in the evening of the third day and in the morning before image acquisition. Images were acquired by a single-slice detector spiral CT (computed tomography) scanner with 5 mm collimation, 1 mm reconstruction, 1.5-2.0:1.0 pitch, 100-150 mA, and 120 kVp after the colons were inflated by CO2. The contrasted colonic residue materials were electronically removed from the CT images by specialized computer-segmentation algorithms. Results: By assumptions that the healthy young volunteers have no polyp and the image resolution is approximately 4 mm, a successful electronic cleansing is defined as "no more than five false positives and no removal of a colon fold part greater than 4 mm" for each study case. The successful rate is 100% for protocol Diet-1, 77% for Diet-2 and 57% for Diet-3. Conclusion: A laxative-free bowel preparation is feasible for virtual colonoscopy.

  19. Meat intake and risk of colorectal polyps: results from a large population-based screening study in Germany.

    Science.gov (United States)

    Carr, Prudence R; Holleczek, Bernd; Stegmaier, Christa; Brenner, Hermann; Hoffmeister, Michael

    2017-06-01

    Background: Red and processed meats have been shown to be associated with colorectal adenomas in many, but not all, studies, and the association according to the type of colorectal adenoma or the location in the colorectum is unclear. Objectives: We investigated the association of meat intake in relation to colorectal polyps and further investigated the association according to histologic subtypes and subsites in a large population-based screening study in Germany. Design: In this cross-sectional study, 15,950 participants aged ≥55 y underwent a screening colonoscopy. We calculated prevalence ratios (PRs) and 95% CIs for associations between meat intake and the most-advanced findings from a colonoscopy with the use of log binomial regression. Results: Overall, 3340 participants (20.4%) had nonadvanced adenomas, 1643 participants (10.0%) had advanced adenomas, and 189 participants (1.2%) had colorectal cancer. We observed no statistically significant association between red or processed meat consumption and the prevalence of any adenomas or advanced adenomas [highest compared with lowest: red meat, PR: 1.07 (95% CI: 0.83, 1.37); processed meat, PR: 1.11 (95% CI: 0.91, 1.36)]. In site-specific analyses, although no dose-response relation was observed, processed meat was positively associated with the prevalence of advanced adenomas in the rectum only (multiple times per day compared with meat intake and the prevalence of any adenomas or advanced adenomas. However, processed meat may be positively associated with the prevalence of advanced adenomas in the rectum, but prospective cohort studies are needed to further clarify this association. There is no association between poultry consumption and the prevalence of colorectal polyps in this study. © 2017 American Society for Nutrition.

  20. Body Mass Index and Cancer Screening in Older American Indian and Alaska Native Men

    Science.gov (United States)

    Muus, Kyle J.; Baker-Demaray, Twyla; McDonald, Leander R.; Ludtke, Richard L.; Allery, Alan J.; Bogart, T. Andy; Goldberg, Jack; Ramsey, Scott D.; Buchwald, Dedra S.

    2009-01-01

    Context: Regular screenings are important for reducing cancer morbidity and mortality. There are several barriers to receiving timely cancer screening, including overweight/obesity. No study has examined the relationship between overweight/obesity and cancer screening among American Indian/Alaska Natives (AI/ANs). Purpose: To describe the…

  1. Practical determination of sensitometric properties of medical film-screen combinations

    International Nuclear Information System (INIS)

    Vassileva, J.; Ibrachim, K.

    2000-01-01

    The aim of the study is to to compare different sensitometric techniques for medical film-screen systems and to chose the optimal one for practical use in a clinical environment and to compare the sensitometric properties of different film-screen combinations practically used for chest radiography. The measurement have been performed using TUR D800-3 radiographic installation with twelve-pulse generator and DRX 124/30/60 oDw tube. The following screens and cassettes have been investigated: VARIMEX (Poland) with PERLUX screens (Germany); DuPomt cassette with QFD screens; Kodak X-Omatic LW cassette with Lanex Regular screens. They have been combined with 4 types of films: Sterling Cronex4 (blue); Agfa CP-BU New (blue); Agfa CP-G Plus (ortho) and Kodak TMG-RA (ortho). All cassettes have been examined for light tightness and screen-film contact and all film types have been checked for the compatibility with the safe lights in the darkroom. To simulate a patient for a chest radiography standard LucAl chest phantom has been designed. The measurements show that: 1) Sensitivity of Kodak cassette with green emitting rare-earth Kodak Lanex Regular screens combined with ortho Kodak film is highest; 2) From two emitting screens - PERLUX and QFD. both combined with blue sensitive films, QFD is 3.6 times more sensitive. 3) Films Agfa CP-BU New and Cronex 4 are of the same sensitivity class but the first has higher contrast. 4) The use of ortho-chromatic films in combination with PERLUX or QGD blue emitting screens results in a considerable loss of sensitivity

  2. A score to estimate the likelihood of detecting advanced colorectal neoplasia at colonoscopy.

    Science.gov (United States)

    Kaminski, Michal F; Polkowski, Marcin; Kraszewska, Ewa; Rupinski, Maciej; Butruk, Eugeniusz; Regula, Jaroslaw

    2014-07-01

    This study aimed to develop and validate a model to estimate the likelihood of detecting advanced colorectal neoplasia in Caucasian patients. We performed a cross-sectional analysis of database records for 40-year-old to 66-year-old patients who entered a national primary colonoscopy-based screening programme for colorectal cancer in 73 centres in Poland in the year 2007. We used multivariate logistic regression to investigate the associations between clinical variables and the presence of advanced neoplasia in a randomly selected test set, and confirmed the associations in a validation set. We used model coefficients to develop a risk score for detection of advanced colorectal neoplasia. Advanced colorectal neoplasia was detected in 2544 of the 35,918 included participants (7.1%). In the test set, a logistic-regression model showed that independent risk factors for advanced colorectal neoplasia were: age, sex, family history of colorectal cancer, cigarette smoking (padvanced neoplasia: 1.00 (95% CI 0.95 to 1.06)) and had moderate discriminatory power (c-statistic 0.62). We developed a score that estimated the likelihood of detecting advanced neoplasia in the validation set, from 1.32% for patients scoring 0, to 19.12% for patients scoring 7-8. Developed and internally validated score consisting of simple clinical factors successfully estimates the likelihood of detecting advanced colorectal neoplasia in asymptomatic Caucasian patients. Once externally validated, it may be useful for counselling or designing primary prevention studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Short Communication: Viral Suppression Is Associated with Increased Likelihood of Colorectal Cancer Screening Among Persons Living with HIV/AIDS.

    Science.gov (United States)

    Burkholder, Greer A; Tamhane, Ashutosh R; Appell, Lauren E; Willig, James H; Saag, Michael S; Raper, James L; Westfall, Andrew O; Mugavero, Michael J

    2015-05-01

    With improved survival and aging, more persons living with HIV/AIDS (PLWHA) are at risk for colorectal cancer (CRC). This retrospective longitudinal study evaluated patient characteristics associated with CRC screening in our HIV cohort. Patients were followed beginning at age 50 years during a study period from January 1, 2003 to December 31, 2010 (n=265). During a median follow-up time of 1.7 years, only 30% of patients underwent CRC screening. The majority of screened patients received endoscopic screening (colonoscopy, 86%; sigmoidoscopy, 8%); among these patients, results were available for 68/75, and adenomatous polyps were found in 13%. No cases of CRC were reported. Among unscreened patients, only 23% had an external primary care provider, indicating an HIV provider was the expected source for CRC screening referral in the majority. Patients with time-varying suppressed HIV viral load were more likely to receive screening (HRadjusted=1.74; 95% CI: 1.05-2.87), independent of CD4 count. Our findings suggest HIV providers are more likely to address non-HIV-related healthcare maintenance when HIV is controlled. In addition, a significant number of neoplastic lesions are likely being missed in PLWHA who have not been screened for CRC. Provision of evidence-based preventive care in addition to HIV care is required for the aging population of PLWHA.

  4. Predicting inadequate bowel preparation for colonoscopy in participants receiving split-dose bowel preparation: development and validation of a prediction score

    NARCIS (Netherlands)

    Dik, V.K.; Moons, L.M.; Huyuk, M.; Schaar, P. van der; Cappel, W.H. de Vos Tot Nede; Borg, P.C. ter; Meijssen, M.A.; Ouwendijk, R.J.; Fevre, D.M. Le; Stouten, M.; Galien, O. van der; Hiemstra, T.J.; Monkelbaan, J.F.; Oijen, M.G. van; Siersema, P.D.

    2015-01-01

    BACKGROUND: Adequate bowel preparation is important for optimal colonoscopy. It is important to identify patients at risk for inadequate bowel preparation because this allows taking precautions in this specific group. OBJECTIVE: To develop a prediction score to identify patients at risk for

  5. Predicting inadequate bowel preparation for colonoscopy in participants receiving split-dose bowel preparation : Development and validation of a prediction score

    NARCIS (Netherlands)

    Dik, Vincent K.; Moons, Leon M G; Hüyük, Melek; Van Der Schaar, Peter; De Vos Tot Nederveen Cappel, Wouter H.; Ter Borg, Pieter C J; Meijssen, Maarten A C; Ouwendijk, Rob J T H; Le Fèvre, Doris M.; Stouten, Merijn; Van Der Galiën, Onno; Hiemstra, Theo J.; Monkelbaan, Jan F.; van Oijen, Martijn G. H.; Siersema, Peter D.; Tang, Thjon J.; Ter Borg, Frank; Kuipers, Ernst J.

    2015-01-01

    Background: Adequate bowel preparation is important for optimal colonoscopy. It is important to identify patients at risk for inadequate bowel preparation because this allows taking precautions in this specific group. Objective: To develop a prediction score to identify patients at risk for

  6. Developing Partnerships to Reduce Disparities in Cancer Screening

    OpenAIRE

    Breslau, Erica S.; Rochester, Phyllis W.; Saslow, Debbie; Crocoll, Caroline E.; Johnson, Lenora E.; Vinson, Cynthia A.

    2010-01-01

    Background Interventions in scientific settings to improve the well-being of women who are not regularly screened for cancer have failed. Consequently, community-based prevention and control efforts are needed. Community Context From 2003 through 2007, three federal agencies and 1 nongovernmental agency collaborated with county-level public health counterparts from 6 states to address screening disparities in cervical and breast cancer in counties with the highest prevalence. This case study ...

  7. The benefits and harms of screening for cancer with a focus on breast screening

    DEFF Research Database (Denmark)

    Brodersen, John; Juhl Jørgensen, Karsten; Gøtzsche, Peter C.

    2010-01-01

    . The effects of routine clinical breast examination are unknown, but considering the results of the breast self-examination trials, it is likely that it is harmful. The effects of screening for breast cancer with thermography, ultrasound or magnetic resonance imaging are unknown. It is not clear whether......The balance between benefits and harms is delicate for cancer screening programs. By attending screening with mammography some women will avoid dying from breast cancer or receive less aggressive treatment. But many more women will be overdiagnosed, receive needless treatment, have a false...... and will be treated unnecessarily. Furthermore, more than 200 women will experience substantial psychosocial distress for months because of false-positive findings. Regular breast self-examination does not reduce breast cancer mortality, but doubles the number of biopsies, and it therefore cannot be recommended...

  8. 99 mTc antigranulocyte monoclonal antibody imaging for the detection and assessment of inflammatory bowel disease newly diagnosed by colonoscopy in children

    International Nuclear Information System (INIS)

    Charron, M.; Hickeson, M.P.

    2001-01-01

    Objective: This prospective study evaluated a 99m Tc antigranulocyte monoclonal antibody Fab' imaging agent (Sulesomab) in children with inflammatory bowel disease (IBD) newly diagnosed by colonoscopy. Materials and methods: Ten children (4 boys, 6 girls; mean age 14 years) with newly diagnosed Crohn's disease (n = 6) or ulcerative colitis (n = 4) were studied. Colonoscopy was performed in all of these patients. Within 24 h after colonoscopy, they underwent scintigraphy with 99 m Tc-Sulesomab. Abdominal/pelvic images were acquired at 30 min (planar) and 2-4 h (planar and SPECT) after injection of Sulesomab. Eighty bowel segments were evaluated semi-quantitatively by the investigators, using these three sets of images. The Pediatric Disease Activity (PDA) was correlated with the erythrocyte sedimentation rate (ESR), white blood cell (WBC) count, albumin, Kirschner's score, the Sulesomab bowel segment with maximum uptake, and the sum of Sulesomab score in each segment. Results: The median PDA score was 26 (range 12.5-40). Three children had normal ESR and six normal WBC counts. All patients had at least one positive mucosal biopsy for IBD. While using the Kirschner's scale, the maximal severity of colonoscopy findings was graded as none (n = 2), mild (n = 4), moderate (n = 3), or severe (n = 1). Of the 59 segments evaluated with endoscopy, 35 were found to be endoscopically abnormal. The planar images identified 17 of these abnormal segments and the SPECT images 20. Nine of these ten children had abnormal bowel uptake by scintigraphy. Thus, the sensitivity of Sulesomab per patient was 90 % and per bowel segment 57 %. The correlation coefficient between the scintigraphic score for the segment with the Sulesomab maximum activity and the PDA was 0.3 (P = 0.41). Conclusion: In pediatric IBD assessment, planar imaging with Sulesomab did not prove very sensitive in detecting inflammation in each bowel segment. However, SPECT detected the presence of inflammation in the

  9. Comparison of a 4-Day versus 2-Day Low Fiber Diet Regimen in Barium Tagging CT Colonography in Incomplete Colonoscopy Patients

    Directory of Open Access Journals (Sweden)

    Kaan Meric

    2015-01-01

    Full Text Available Our aim was to compare the amount of residual feces, residual fluid, the tagging quality, and patient compliance using 4-day versus 2-day low fiber diet regimen in barium tagging CT colonography in incomplete colonoscopy patients. Methods. A total of 101 patients who underwent CT colonography were assigned to 2-day diet group (n=56 and 4-day diet group (n=45. Fecal tagging was achieved with barium sulphate while bisacodyl and sennoside B were used for bowel preparation. Residual solid stool was divided into two groups measuring 0.05. The prevalence of moderate discomfort was significantly higher in 4-day group (P<0.001. Conclusion. Our study shows that 2-day limited bowel preparation regimen for fecal tag CT colonography is a safe and reasonable technique to evaluate the entire colon, particularly in incomplete conventional colonoscopy patients.

  10. [Appendectomy for appendicitis by colonoscopy after a cecal invagination of the appendix during childhood].

    Science.gov (United States)

    Blanc, P; Delacoste, F; Chevassus, P; Espin, A; Kadam, A; Atger, J

    2007-01-01

    Appendiceal intussusception (the inside-out appendix) was often practiced in pediatric surgery when the appendectomy was performed during laparotomy. Complications are exceptional. We report the first case of appendiceal intussusception in an adult appendectomized by this procedure during childhood, reviewing the radiological aspect, pathogenesis, and treatment. This delayed complication of appendiceal intussusception should be known to the surgeon. Treatment during colonoscopy is possible. This inflammation of the vaginated appendix can be prevented by coagulating the appendicular vessels to the serous membrane before turning it inside-out.

  11. USING A MULTIFACETED APPROACH TO IMPROVE THE FOLLOW-UP OF POSITIVE FECAL OCCULT BLOOD TEST RESULTS

    Science.gov (United States)

    Singh, Hardeep; Kadiyala, Himabindu; Bhagwath, Gayathri; Shethia, Anila; El-Serag, Hashem; Walder, Annette; Velez, Maria; Petersen, Laura A.

    2010-01-01

    Background Inadequate follow-up of abnormal fecal occult blood test (FOBT) results occurs in several types of practice settings. Our institution implemented multifaceted quality improvement (QI) activities in 2004–2005 to improve follow-up of FOBT positive results. Activities addressed pre-colonoscopy referral processes and system-level factors such as electronic communication and provider education and feedback. We evaluated their effects on timeliness and appropriateness of positive FOBT follow-up and identified factors that affect colonoscopy performance. Methods Retrospective electronic medical record (EMR) review was used to determine outcomes pre- and post-QI activities in a multi-specialty ambulatory clinic of a tertiary care Veterans Affairs facility and its affiliated satellite clinics. From 1869 FOBT positive cases, 800 were randomly selected from time periods before and after QI activities. Two reviewers used a pretested standardized data collection form to determine whether colonoscopy was appropriate or indicated based on pre-determined criteria and if so, the timeliness of colonoscopy referral and performance pre- and post-QI activities. Results In cases where a colonoscopy was indicated, the proportion of patients who received a timely colonoscopy referral and performance were significantly higher post implementation (60.5% vs. 31.7%, pperformance (6 vs. 19 days pperformance of an indicated colonoscopy included performance of a non-colonoscopy procedure such as barium enema or flexible sigmoidoscopy (OR=16.9; 95% CI 1.9–145.1), patient non-adherence (OR=33.9; 95% CI 17.3–66.6), not providing an appropriate provisional diagnosis on the consultation (OR= 17.9; 95% CI 11.3–28.1) and gastroenterology service not rescheduling colonoscopies after an initial cancellation (OR= 11.0; 95% CI 5.1–23.7) Conclusions Multifaceted QI activities improved rates of timely colonoscopy referral and performance in an EMR system. However, colonoscopy was not

  12. A randomised controlled trial: can acupuncture reduce drug requirement during analgosedation with propofol and alfentanil for colonoscopy? A study protocol

    NARCIS (Netherlands)

    Eberl, Susanne; Monteiro de Olivera, Nelson; Preckel, Benedikt; Streitberger, Konrad; Fockens, Paul; Hollmann, Markus W.

    2015-01-01

    The number of colonoscopies tremendously increased in recent years and will further rise in the near future. Because of patients' growing expectation on comfort during medical procedures, it is not surprising that the demand for sedation also expands. Propofol in combination with alfentanil is known

  13. Distance-regular graphs

    NARCIS (Netherlands)

    van Dam, Edwin R.; Koolen, Jack H.; Tanaka, Hajime

    2016-01-01

    This is a survey of distance-regular graphs. We present an introduction to distance-regular graphs for the reader who is unfamiliar with the subject, and then give an overview of some developments in the area of distance-regular graphs since the monograph 'BCN'[Brouwer, A.E., Cohen, A.M., Neumaier,

  14. Quality of colonoscopy performance among gastroenterology and surgical trainees: a need for common training standards for all trainees?

    LENUS (Irish Health Repository)

    Leyden, J E

    2011-11-01

    Cecal intubation and polyp detection rates are objective measures of colonoscopy performance. Minimum cecal intubation rates greater than 90% have been endorsed by the American Society for Gastrointestinal Endoscopy (ASGE) and the Joint Advisory Group (JAG) UK. Performance data for medical and surgical trainee endoscopists are limited, and we used endoscopy quality parameters to compare these two groups.

  15. Regular expressions cookbook

    CERN Document Server

    Goyvaerts, Jan

    2009-01-01

    This cookbook provides more than 100 recipes to help you crunch data and manipulate text with regular expressions. Every programmer can find uses for regular expressions, but their power doesn't come worry-free. Even seasoned users often suffer from poor performance, false positives, false negatives, or perplexing bugs. Regular Expressions Cookbook offers step-by-step instructions for some of the most common tasks involving this tool, with recipes for C#, Java, JavaScript, Perl, PHP, Python, Ruby, and VB.NET. With this book, you will: Understand the basics of regular expressions through a

  16. A low-volume polyethylene glycol solution was associated with an increased suboptimal bowel preparation rate but had similar recommendations for an early repeat colonoscopy, procedure times, and adenoma detection rates.

    Directory of Open Access Journals (Sweden)

    Sam C Hankins

    Full Text Available Low-volume polyethylene glycol (PEG bowel preparations are better tolerated by patients than high-volume preparations and may achieve similar preparation quality. However, there is little data comparing their effects on a recommendation for an early repeat colonoscopy (because of a suboptimal preparation, procedure times, adenoma detection rate (ADR, and advanced adenoma detection rate (AADR.This is a retrospective cohort study of outpatient colonoscopies performed during a one-year period at a single academic medical center in which low-volume MoviPrep® (n = 1841 or high-volume Colyte® (n = 1337 was used. All preparations were split-dosed. Appropriate covariates were included in regression models assessing suboptimal preparation quality (fair, poor, or inadequate, procedure times, recommendation for an early repeat colonoscopy, ADR, and AADR.MoviPrep® was associated with an increase in having a suboptimal bowel preparation (OR 1.36; 95% CI: 1.06-1.76, but it was not associated with differences in insertion (p = 0.43, withdrawal (p = 0.22, or total procedure times (p = 0.10. The adjusted percentage with a suboptimal preparation was 11.7% for patients using MoviPrep® and 8.8% for patients using Colyte®. MoviPrep® was not associated with a significant difference in overall ADR (OR 0.93; 95% CI: 0.78-1.11, AADR (OR 1.18; 95% CI: 0.87-1.62, or recommendation for early repeat colonoscopy (OR 1.16; 95% CI: 0.72-1.88.MoviPrep® was associated with a small absolute increase in having a suboptimal preparation, but did not affect recommendations for an early repeat colonoscopy, procedure times, or adenoma detection rates. Mechanisms to reduce financial barriers limiting low-volume preparations should be considered because of their favorable tolerability profile.

  17. Prototype of a computer system for managing data and video colonoscopy exams

    Directory of Open Access Journals (Sweden)

    Renato Bobsin Machado

    2012-03-01

    Full Text Available OBJECTIVE: Develop a prototype using computer resources to optimize the management process of clinical information and video colonoscopy exams. MATERIALS AND METHODS: Through meetings with medical and computer experts, the following requirements were defined: management of information about medical professionals, patients and exams; video and image captured by video colonoscopes during the exam, and the availability of these videos and images on the Web for further analysis. The technologies used were Java, Flex, JBoss, Red5, JBoss SEAM, MySQL and Flamingo. RESULTS AND DISCUSSION: The prototype contributed to the area of colonocospy by providing resources to maintain the patients' history, tests and images from video colonoscopies. The web-based application allows greater flexibility to physicians and specialists. The resources for remote analysis of data and tests can help doctors and patients in the examination and diagnosis. CONCLUSION: The implemented prototype has contributed to improve colonoscopy-related processes. Future activities include the prototype deployment in the Service of Coloproctology and the utilization of this model to allow real-time monitoring of these exams and knowledge extraction from such structured database using artificial intelligence.OBJETIVO: Desenvolver um protótipo por meio de recursos computacionais para a otimização de processos de gerenciamento de informações clínicas e de exames de videocolonoscopia. MATERIAIS E MÉTODOS: Por meio de reuniões com especialistas médicos e computacionais, definiram-se os seguintes requisitos: gestão de informações sobre profissionais médicos, pacientes e exames complementares; aquisição dos vídeos e captura de imagens a partir do videocolonoscópio durante a realização desse exame, e a disponibilidade por meio da Web para análise posterior dessas imagens. As tecnologias aplicadas foram: Java, Flex, JBOSS, Red5, JBOSS SEAM, MySQL e Flamingo. RESULTADOS E

  18. LL-regular grammars

    NARCIS (Netherlands)

    Nijholt, Antinus

    1980-01-01

    Culik II and Cogen introduced the class of LR-regular grammars, an extension of the LR(k) grammars. In this paper we consider an analogous extension of the LL(k) grammars called the LL-regular grammars. The relation of this class of grammars to other classes of grammars will be shown. Any LL-regular

  19. Effective colonoscopy training techniques: strategies to improve patient outcomes.

    Science.gov (United States)

    Papanikolaou, Ioannis S; Karatzas, Pantelis S; Varytimiadis, Lazaros T; Tsigaridas, Athanasios; Galanopoulos, Michail; Viazis, Nikos; Karamanolis, Dimitrios G

    2016-01-01

    Colonoscopy has substantially evolved during the last 20 years and many different training techniques have been developed in order to improve the performance of endoscopists. The most known are mechanical simulators, virtual reality simulators, computer-simulating endoscopy, magnetic endoscopic imaging, and composite and explanted animal organ simulators. Current literature generally indicates that the use of simulators improves performance of endoscopists and enhances safety of patients, especially during the initial phase of training. Moreover, newer endoscopes and imaging techniques such as high-definition colonoscopes, chromocolonoscopy with dyes spraying, and third-eye retroscope have been incorporated in everyday practice, offering better visualization of the colon and detection of polyps. Despite the abundance of these different technological features, training devices are not widely used and no official guideline or specified training algorithm or technique for lower gastrointestinal endoscopy has been evolved. In this review, we present the most important training methods currently available and evaluate these using existing literature. We also try to propose a training algorithm for novice endoscopists.

  20. Polyethylene Glycol Electrolyte Lavage Solution versus Colonic Hydrotherapy for Bowel Preparation before Colonoscopy: A Single Center, Randomized, and Controlled Study

    Directory of Open Access Journals (Sweden)

    Yan Cao

    2014-01-01

    Full Text Available This single center, randomized, and controlled study aimed to compare the effectiveness and safety of polyethylene glycol electrolyte lavage (PEG-EL solution and colonic hydrotherapy (CHT for bowel preparation before colonoscopy. A total of 196 eligible outpatients scheduled for diagnostic colonoscopy were randomly assigned to the PEG-EL (n=102 or CHT (n=94 groups. Primary outcome measures included colonic cleanliness and adverse effects. Secondary outcome measures were patient satisfaction and preference, colonoscopic findings, ileocecal arrival rate, examiner satisfaction, and cecal intubation time. The results show that PEG-EL group was associated with significantly better colonic cleanliness than CHT group, fewer adverse effects, and increased examiner satisfaction. However, the CHT group had higher patient satisfaction and higher diverticulosis detection rates. Moreover, the results showed the same ileocecal arrival rate and patient preference between the two groups (P>0.05. These findings indicate that PEG-EL is the preferred option in patients who followed the preparation instructions completely.