WorldWideScience

Sample records for registration electronic resource

  1. 77 FR 66920 - Registration of Claims to Copyright: Group Registration of Serial Issues Filed Electronically

    Science.gov (United States)

    2012-11-08

    ... registered on a single application and for a single fee. The group registration privilege is contingent upon... was limited to basic registrations, i.e., claims in single works, while the capacity to process online... of related serials. Revisions to the electronic registration system will upgrade the capacity of the...

  2. Family Registration Card as electronic medical carrier in Bosnia and Herzegovina.

    Science.gov (United States)

    Novo, Ahmed; Masic, Izet; Toromanovic, Selim; Loncarevic, Nedim; Junuzovic, Dzelaludin; Dizdarevic, Jadranka

    2004-01-01

    Medical documentation is a very important part of the medical documentalistics and is occupies a large part of daily work of medical staff working in Primary Health Care. Paper documentation is going to be replaced by electronic cards in Bosnia and Herzegovina and a new Health Care System is under development, based on an Electronic Family Registration Card. Developed countries proceeded from the manual and semiautomatic method of medical data processing to the new method of entering, storage, transferring, searching and protecting data, using electronic equipment. Currently, many European countries have developed a Medical Card Based Electronic Information System. Three types of electronic card are currently in use: a Hybrid Card, a Smart Card and a Laser Card. The dilemma is which card should be used as a data carrier. The Electronic Family Registration Cared is a question of strategic interest for B&H, but also a great investment. We should avoid the errors of other countries that have been developing card-based system. In this article we present all mentioned cards and compare advantages and disadvantages of different technologies.

  3. An Effort to Increase Organ Donor Registration Through Intergroup Competition and Electronic Word of Mouth.

    Science.gov (United States)

    Smith, Sandi W; Hitt, Rose; Park, Hee Sun; Walther, Joseph; Liang, Yuhua Jake; Hsieh, Gary

    2016-01-01

    The effort to increase Web organ donation registrations in Michigan by enhancing 2 types of university campaigns with social media strategies informed by social identity theory is the focus of this research. The two campaigns focused on either ingroup or rivalry outgroup social identification, and each was enhanced with individually focused social media in the first year of the campaign and with electronic word of mouth in Year 2 of the campaign. Results indicated that individually focused social media such as Facebook ads worked well in rivalry campaigns (in which registrations increased two times over baseline) but not in ingroup identification campaigns (in which registrations decreased significantly over baseline when ads were introduced in the first year of each type of campaign). Electronic word-of-mouth strategies worked well in both ingroup identification campaigns (in which registrations increased two times over baseline) and rivalry campaigns (in which registrations rose almost eight times over baseline, when strategies were introduced in the second year of each type of campaign).

  4. The electronic system for mechanical oscillation parameters registration

    Directory of Open Access Journals (Sweden)

    Bulavin L. A.

    2008-08-01

    Full Text Available On the basis of the 8-bit microcontroller Microchip PIC16F630 the digital electronic device for harmonic oscillation parameters registration was developed. The device features are simple electric circuit and high operating speed (response time is less than 10 microseconds. The relevant software for the computer-controlled recording of harmonic oscillation parameters was designed. The device can be used as a part of the experimental setup for consistent fluids rheological parameters measurements.

  5. Tenure Security Reformand Electronic Registration: Exploring ...

    African Journals Online (AJOL)

    This paper examines the potential significance of updating registration practices in resolving some of the issues about tenure security in a transformative context. It deals with the importance of good governance in the context of land administration and considers its impact on intended reforms. Land registration practice as an ...

  6. Electronic Resource Management and Design

    Science.gov (United States)

    Abrams, Kimberly R.

    2015-01-01

    We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…

  7. Electronic Resource Management Systems

    Directory of Open Access Journals (Sweden)

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  8. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-11-05

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration is to consolidate all electronic resources into a single and centralized location. This would allow for better information sharing among library staff.

  9. PRINCIPLES OF CONTENT FORMATION EDUCATIONAL ELECTRONIC RESOURCE

    Directory of Open Access Journals (Sweden)

    О Ю Заславская

    2017-12-01

    Full Text Available The article considers modern possibilities of information and communication technologies for the design of electronic educational resources. The conceptual basis of the open educational multimedia system is based on the modular architecture of the electronic educational resource. The content of the electronic training module can be implemented in several versions of the modules: obtaining information, practical exercises, control. The regularities in the teaching process in modern pedagogical theory are considered: general and specific, and the principles for the formation of the content of instruction at different levels are defined, based on the formulated regularities. On the basis of the analysis, the principles of the formation of the electronic educational resource are determined, taking into account the general and didactic patterns of teaching.As principles of the formation of educational material for obtaining information for the electronic educational resource, the article considers: the principle of methodological orientation, the principle of general scientific orientation, the principle of systemic nature, the principle of fundamentalization, the principle of accounting intersubject communications, the principle of minimization. The principles of the formation of the electronic training module of practical studies in the article include: the principle of systematic and dose based consistency, the principle of rational use of study time, the principle of accessibility. The principles of the formation of the module for monitoring the electronic educational resource can be: the principle of the operationalization of goals, the principle of unified identification diagnosis.

  10. Implementing CORAL: An Electronic Resource Management System

    Science.gov (United States)

    Whitfield, Sharon

    2011-01-01

    A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…

  11. Information System of Resolution of Procedural Incidents and Management of the Modifications Made to the Electronic Court Registration

    Directory of Open Access Journals (Sweden)

    Ştefan Gheorghe PENTIUC

    2011-01-01

    Full Text Available This information system was made for its use by the staff responsible for random distribution of cases to the courts. The Information System of Resolution of Procedural Incidents and Management of the Modifications Made to the Electronic Court Registration consists of three new developed modules: the management module is a Web application which chronicles the modifications made in the electronic court registration, regarding the random assignment of cases,the resolution of procedural incidents, which is a Web service whose logic implements a logic Semantic Web application and the module of confirming judges which is a windows service running on the judges’ workstations. The Web service implements a Semantic Web application which processes the knowledgebase achieved through OWL ontology (Ontology Web Language by applying inferences leading to the correct solution. If this does not solve the problem, a set of associated Jena rules are used to infer and generate new knowledge. It also uses the SPARQL(SPARQL Protocol and RDF Query Language language that allows queries on the knowledge,similar to the classic query languages of databases. The novelty of the new conceived, designed and implemented system consists in accessing the domain knowledge as a web service to solve the procedural incidents occurred in electronic court registration.

  12. Managing electronic resources a LITA guide

    CERN Document Server

    Weir, Ryan O

    2012-01-01

    Informative, useful, current, Managing Electronic Resources: A LITA Guide shows how to successfully manage time, resources, and relationships with vendors and staff to ensure personal, professional, and institutional success.

  13. Gender Analysis Of Electronic Information Resource Use: The Case ...

    African Journals Online (AJOL)

    Based on the findings the study concluded that access and use of electronic information resources creates a “social digital divide” along gender lines. The study ... Finally, the library needs to change its marketing strategies on the availability of electronic information resources to increase awareness of these resources.

  14. Users satisfaction with electronic information resources and services ...

    African Journals Online (AJOL)

    This study investigated users satisfaction on the use of electronic information resources and services in MTN Net libraries in ABU & UNIBEN. Two objectives and one null hypotheses were formulated and tested with respect to the users' satisfaction on electronic information resources and services in MTN Net libraries in ...

  15. Organizational matters of competition in electronic educational resources

    Directory of Open Access Journals (Sweden)

    Ирина Карловна Войтович

    2015-12-01

    Full Text Available The article examines the experience of the Udmurt State University in conducting competitions of educational publications and electronic resources. The purpose of such competitions is to provide methodological support to educational process. The main focus is on competition of electronic educational resources. The technology of such contests is discussed through detailed analysis of the main stages of the contest. It is noted that the main task of the preparatory stage of the competition is related to the development of regulations on competition and the definition of criteria for selection of the submitted works. The paper also proposes a system of evaluation criteria of electronic educational resources developed by members of the contest organizing committee and jury members. The article emphasizes the importance of not only the preparatory stages of the competition, but also measures for its completion, aimed at training teachers create quality e-learning resources.

  16. CHALLENGES OF ELECTRONIC INFORMATION RESOURCES IN ...

    African Journals Online (AJOL)

    This paper discusses the role of policy for proper and efficient library services in the electronic era. It points out some of the possible dangers of embarking in electronic resources without a proper focus at hand. Thus, it calls for today's librarians and policy makers to brainstorm and come up with working policies suitable to ...

  17. Use of Electronic Resources in a Private University in Nigeria ...

    African Journals Online (AJOL)

    The study examined awareness and constraints in the use of electronic resources by lecturers and students of Ajayi Crowther University, Oyo, Nigeria. It aimed at justifying the resources expended in the provision of electronic resources in terms of awareness, patronage and factors that may be affecting awareness and use ...

  18. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  19. Spline-based image-to-volume registration for three-dimensional electron microscopy

    International Nuclear Information System (INIS)

    Jonic, S.; Sorzano, C.O.S.; Thevenaz, P.; El-Bez, C.; De Carlo, S.; Unser, M.

    2005-01-01

    This paper presents an algorithm based on a continuous framework for a posteriori angular and translational assignment in three-dimensional electron microscopy (3DEM) of single particles. Our algorithm can be used advantageously to refine the assignment of standard quantized-parameter methods by registering the images to a reference 3D particle model. We achieve the registration by employing a gradient-based iterative minimization of a least-squares measure of dissimilarity between an image and a projection of the volume in the Fourier transform (FT) domain. We compute the FT of the projection using the central-slice theorem (CST). To compute the gradient accurately, we take advantage of a cubic B-spline model of the data in the frequency domain. To improve the robustness of the algorithm, we weight the cost function in the FT domain and apply a 'mixed' strategy for the assignment based on the minimum value of the cost function at registration for several different initializations. We validate our algorithm in a fully controlled simulation environment. We show that the mixed strategy improves the assignment accuracy; on our data, the quality of the angular and translational assignment was better than 2 voxel (i.e., 6.54 A). We also test the performance of our algorithm on real EM data. We conclude that our algorithm outperforms a standard projection-matching refinement in terms of both consistency of 3D reconstructions and speed

  20. use of electronic resources by graduate students of the department

    African Journals Online (AJOL)

    respondent's access electronic resources from the internet via Cybercafé .There is a high ... KEY WORDS: Use, Electronic Resources, Graduate Students, Cybercafé. INTRODUCTION ... Faculty of Education, University of Uyo, Uyo. Olu Olat ...

  1. Electronic resource management practical perspectives in a new technical services model

    CERN Document Server

    Elguindi, Anne

    2012-01-01

    A significant shift is taking place in libraries, with the purchase of e-resources accounting for the bulk of materials spending. Electronic Resource Management makes the case that technical services workflows need to make a corresponding shift toward e-centric models and highlights the increasing variety of e-formats that are forcing new developments in the field.Six chapters cover key topics, including: technical services models, both past and emerging; staffing and workflow in electronic resource management; implementation and transformation of electronic resource management systems; the ro

  2. Utilization of electronic information resources by academic staff at ...

    African Journals Online (AJOL)

    The study investigated the utilization of Electronic Information resources by the academic staff of Makerere University in Uganda. It examined the academic staff awareness of the resources available, the types of resources provided by the Makerere University Library, the factors affecting resource utilization. The study was ...

  3. Electronic Submission of Labels

    Science.gov (United States)

    Pesticide registrants can provide draft and final labels to EPA electronically for our review as part of the pesticide registration process. The electronic submission of labels by registrants is voluntary but strongly encouraged.

  4. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-01-01

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration

  5. Practical guide to electronic resources in the humanities

    CERN Document Server

    Dubnjakovic, Ana

    2010-01-01

    From full-text article databases to digitized collections of primary source materials, newly emerging electronic resources have radically impacted how research in the humanities is conducted and discovered. This book, covering high-quality, up-to-date electronic resources for the humanities, is an easy-to-use annotated guide for the librarian, student, and scholar alike. It covers online databases, indexes, archives, and many other critical tools in key humanities disciplines including philosophy, religion, languages and literature, and performing and visual arts. Succinct overviews of key eme

  6. Registration of Laser Scanning Point Clouds: A Review

    Science.gov (United States)

    Cheng, Liang; Chen, Song; Xu, Hao; Wu, Yang; Li, Manchun

    2018-01-01

    The integration of multi-platform, multi-angle, and multi-temporal LiDAR data has become important for geospatial data applications. This paper presents a comprehensive review of LiDAR data registration in the fields of photogrammetry and remote sensing. At present, a coarse-to-fine registration strategy is commonly used for LiDAR point clouds registration. The coarse registration method is first used to achieve a good initial position, based on which registration is then refined utilizing the fine registration method. According to the coarse-to-fine framework, this paper reviews current registration methods and their methodologies, and identifies important differences between them. The lack of standard data and unified evaluation systems is identified as a factor limiting objective comparison of different methods. The paper also describes the most commonly-used point cloud registration error analysis methods. Finally, avenues for future work on LiDAR data registration in terms of applications, data, and technology are discussed. In particular, there is a need to address registration of multi-angle and multi-scale data from various newly available types of LiDAR hardware, which will play an important role in diverse applications such as forest resource surveys, urban energy use, cultural heritage protection, and unmanned vehicles.

  7. Utilisation of Electronic Information Resources By Lecturers in ...

    African Journals Online (AJOL)

    This study assesses the use of information resources, specifically, electronic databases by lecturers/teachers in Universities and Colleges of Education in South Western Nigeria. Information resources are central to teachers' education. It provides lecturers/teachers access to information that enhances research and ...

  8. Discipline, availability of electronic resources and the use of Finnish National Electronic Library - FinELib

    Directory of Open Access Journals (Sweden)

    Sanna Torma

    2004-01-01

    Full Text Available This study elaborated relations between digital library use by university faculty, users' discipline and the availability of key resources in the Finnish National Electronic Library (FinELib, Finnish national digital library, by using nationwide representative survey data. The results show that the perceived availability of key electronic resources by researchers in FinELib was a stronger predictor of the frequency and purpose of use of its services than users' discipline. Regardless of discipline a good perceived provision of central resources led to a more frequent use of FinELib. The satisfaction with the services did not vary with the discipline, but with the perceived availability of resources.

  9. The Role of the Acquisitions Librarian in Electronic Resources Management

    Science.gov (United States)

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  10. Analysis of Pedagogic Potential of Electronic Educational Resources with Elements of Autodidactics

    Directory of Open Access Journals (Sweden)

    Igor A.

    2018-03-01

    Full Text Available Introduction: in recent years didactic properties of electronic educational resources undergo considerable changes, nevertheless, the question of studying of such complete phenomenon as “an electronic educational resource with autodidactics elements” remains open, despite sufficient scientific base of researches of the terms making this concept. Article purpose – determination of essence of electronic educational resources with autodidactics elements. Materials and Methods: the main method of research was the theoretical analysis of the pedagogical and psychological literature on the problem under study. We used the theoretical (analysis, synthesis, comparison and generalization methods, the method of interpretation, pedagogical modeling, and empirical methods (observation, testing, conversation, interview, analysis of students’ performance, pedagogical experiment, peer review. Results: we detected the advantages of electronic educational resources in comparison with traditional ones. The concept of autodidactics as applied to the subject of research is considered. Properties of electronic educational resources with a linear and nonlinear principle of construction are studied.The influence of the principle of construction on the development of the learners’ qualities is shown. We formulated an integral definition of electronic educational resources with elements of autodidactics, namely, the variability, adaptivity and cyclicity of training. A model of the teaching-learning process with electronic educational resources is developed. Discussion and Conclusions: further development of a problem will allow to define whether electronic educational resources with autodidactics elements pedagogical potential for realization of educational and self-educational activity of teachers have, to modify technological procedures taking into account age features of students, their specialties and features of the organization of process of training of

  11. Preservation and conservation of electronic information resources of ...

    African Journals Online (AJOL)

    The major holdings of the broadcast libraries of the Nigerian Television Authority (NTA) are electronic information resources; therefore, providing safe places for general management of these resources have aroused interest in the industry in Nigeria for sometimes. The need to study the preservation and conservation of ...

  12. Building an electronic resource collection a practical guide

    CERN Document Server

    Lee, Stuart D

    2004-01-01

    This practical book guides information professionals step-by-step through building and managing an electronic resource collection. It outlines the range of electronic products currently available in abstracting and indexing, bibliographic, and other services and then describes how to effectively select, evaluate and purchase them.

  13. Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises

    Science.gov (United States)

    Shao, Fang

    The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.

  14. Using XML Technologies to Organize Electronic Reference Resources

    OpenAIRE

    Huser, Vojtech; Del Fiol, Guilherme; Rocha, Roberto A.

    2005-01-01

    Provision of access to reference electronic resources to clinicians is becoming increasingly important. We have created a framework for librarians to manage access to these resources at an enterprise level, rather than at the individual hospital libraries. We describe initial project requirements, implementation details, and some preliminary results.

  15. Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century

    Science.gov (United States)

    Stachokas, George

    2009-01-01

    The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…

  16. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  17. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    Science.gov (United States)

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half

  18. The Insight ToolKit Image Registration Framework

    Directory of Open Access Journals (Sweden)

    Brian eAvants

    2014-04-01

    Full Text Available Publicly available scientific resources help establish evaluation standards, provide a platform for teaching and improve reproducibility. Version 4 of the Insight ToolKit ( ITK4 seeks to es- tablish new standards in publicly available image registration methodology. ITK4 makes severaladvances in comparison to previous versions of ITK. ITK4 supports both multivariate images and objective functions; it also unifies high-dimensional (deformation field and low-dimensional (affine transformations with metrics that are reusable across transform types and with com- posite transforms that allow arbitrary series of geometric mappings to be chained together seamlessly. Metrics and optimizers take advantage of multi-core resources, when available.Furthermore, ITK4 reduces the parameter optimization burden via principled heuristics that automatically set scaling across disparate parameter types (rotations versus translations. A related approach also constrains steps sizes for gradient-based optimizers. The result is that tuning for different metrics and/or image pairs is rarely necessary allowing the researcher tomore easily focus on design/comparison of registration strategies. In total, the ITK4 contribu- tion is intended as a structure to support reproducible research practices, will provide a more extensive foundation against which to evaluate new work in image registration and also enable application level programmers a broad suite of tools on which to build. Finally, we contextu- alize this work with a reference registration evaluation study with application to pediatric brainlabeling.

  19. Socioeconomic determinants of accessibility to birth registration in Lao PDR.

    Science.gov (United States)

    Nomura, Marika; Xangsayarath, Phonepadith; Takahashi, Kenzo; Kamiya, Yusuke; Siengsounthone, Latsamy; Ogino, Hina; Kobayashi, Jun

    2018-01-08

    The global coverage rate of birth registration is only around 65% for the population of children under five although birth registration secures protection and access to health services that are fundamental rights for all babies. This study aimed to perform a basic analysis of the accessibility to birth registration to better understand how to improve the birth registration system in the Lao PDR. For the analysis of birth registration and related socioeconomic factors, 9576 mother-child pairs were chosen from the data set of The Lao Social Indicator Survey 2011-12. After bivariate analysis with statistical tests including the chi-square test were conducted, logistic regression was performed to determine the variables that statistically influence accessibility to birth registration. Ethno-geographic factors and place of delivery were observed to be the factors associated with birth registration in this analysis. Many mothers in the Lao PDR deliver in their local communities. Therefore, capacity development of various human resources, such as Skilled Birth Attendant, to support the local administrative procedure of birth registration in their communities could be one option to overcoming the bottlenecks in the birth registration process in the Lao PDR.

  20. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  1. Elektronik Bilgi Kaynaklarının Seçimi / Selection of Electronic Information Resources

    Directory of Open Access Journals (Sweden)

    Pınar Al

    2003-04-01

    Full Text Available For many years, library users have used only from the printed media in order to get the information that they have needed. Today with the widespread use of the Web and the addition of electronic information resources to library collections, the use of information in the electronic environment as well as in printed media is started to be used. In time, such types of information resources as, electronic journals, electronic books, electronic encyclopedias, electronic dictionaries and electronic theses have been added to library collections. In this study, selection criteria that can be used for electronic information resources are discussed and suggestions are provided for libraries that try to select electronic information resources for their collections.

  2. Access to electronic resources by visually impaired people

    Directory of Open Access Journals (Sweden)

    Jenny Craven

    2003-01-01

    Full Text Available Research into access to electronic resources by visually impaired people undertaken by the Centre for Research in Library and Information Management has not only explored the accessibility of websites and levels of awareness in providing websites that adhere to design for all principles, but has sought to enhance understanding of information seeking behaviour of blind and visually impaired people when using digital resources.

  3. 78 FR 71629 - Technical Resource for Incident Prevention (TRIPwire) User Registration

    Science.gov (United States)

    2013-11-29

    ... Presidential Directive 19 (HSPD-19), which calls for a unified national policy for the prevention and detection.... Memberships are re-verified annually based on the information users provide upon registration or communication...

  4. Library training to promote electronic resource usage

    DEFF Research Database (Denmark)

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...

  5. Why and How to Measure the Use of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Jean Bernon

    2008-11-01

    Full Text Available A complete overview of library activity implies a complete and reliable measurement of the use of both electronic resources and printed materials. This measurement is based on three sets of definitions: document types, use types and user types. There is a common model of definitions for printed materials, but a lot of questions and technical issues remain for electronic resources. In 2006 a French national working group studied these questions. It relied on the COUNTER standard, but found it insufficient and pointed out the need for local tools such as web markers and deep analysis of proxy logs. Within the French national consortium COUPERIN, a new working group is testing ERMS, SUSHI standards, Shibboleth authentication, along with COUNTER standards, to improve the counting of the electronic resources use. At this stage this counting is insufficient and its improvement will be a European challenge for the future.

  6. Euler European Libraries and Electronic Resources in Mathematical Sciences

    CERN Document Server

    The Euler Project. Karlsruhe

    The European Libraries and Electronic Resources (EULER) Project in Mathematical Sciences provides the EulerService site for searching out "mathematical resources such as books, pre-prints, web-pages, abstracts, proceedings, serials, technical reports preprints) and NetLab (for Internet resources), this outstanding engine is capable of simple, full, and refined searches. It also offers a browse option, which responds to entries in the author, keyword, and title fields. Further information about the Project is provided at the EULER homepage.

  7. Effects of Electronic Information Resources Skills Training for Lecturers on Pedagogical Practices and Research Productivity

    Science.gov (United States)

    Bhukuvhani, Crispen; Chiparausha, Blessing; Zuvalinyenga, Dorcas

    2012-01-01

    Lecturers use various electronic resources at different frequencies. The university library's information literacy skills workshops and seminars are the main sources of knowledge of accessing electronic resources. The use of electronic resources can be said to have positively affected lecturers' pedagogical practices and their work in general. The…

  8. Optimized imaging using non-rigid registration

    International Nuclear Information System (INIS)

    Berkels, Benjamin; Binev, Peter; Blom, Douglas A.; Dahmen, Wolfgang; Sharpley, Robert C.; Vogt, Thomas

    2014-01-01

    The extraordinary improvements of modern imaging devices offer access to data with unprecedented information content. However, widely used image processing methodologies fall far short of exploiting the full breadth of information offered by numerous types of scanning probe, optical, and electron microscopies. In many applications, it is necessary to keep measurement intensities below a desired threshold. We propose a methodology for extracting an increased level of information by processing a series of data sets suffering, in particular, from high degree of spatial uncertainty caused by complex multiscale motion during the acquisition process. An important role is played by a non-rigid pixel-wise registration method that can cope with low signal-to-noise ratios. This is accompanied by formulating objective quality measures which replace human intervention and visual inspection in the processing chain. Scanning transmission electron microscopy of siliceous zeolite material exhibits the above-mentioned obstructions and therefore serves as orientation and a test of our procedures. - Highlights: • Developed a new process for extracting more information from a series of STEM images. • An objective non-rigid registration process copes with distortions. • Images of zeolite Y show retrieval of all information available from the data set. • Quantitative measures of registration quality were implemented. • Applicable to any serially acquired data, e.g. STM, AFM, STXM, etc

  9. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Science.gov (United States)

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  10. Characterization of Foliage Mutants for Plant Variety Registration

    International Nuclear Information System (INIS)

    Affrida Abu Hassan; Shuhaimi Shamsuddin; Zaiton Ahmad

    2011-01-01

    Breeding for new plant varieties requires a substantial investment in terms of skill, labour, material resources and financing. Thus, registration of new plant variety is important to ensure return of revenue and protection of the breeder's right. Before a new variety is registered, it has to comply certain requirements under Plant Variety Protection Act. One of the most important requirements is, the new species/variety must be morphologically distinguishable from existing plant varieties. This paper discusses detailed leaf characteristics of 4 foliage mutants produced by Malaysian Nuclear Agency as part of the requirement for new variety registration. (author)

  11. USE OF ELECTRONIC EDUCATIONAL RESOURCES WHEN TRAINING IN WORK WITH SPREADSHEETS

    Directory of Open Access Journals (Sweden)

    Х А Гербеков

    2017-12-01

    Full Text Available Today the tools for maintaining training courses based on opportunities of information and communication technologies are developed. Practically in all directions of preparation and on all subject matters electronic textbook and self-instruction manuals are created. Nevertheless the industry of computer educational and methodical materials actively develops and gets more and more areas of development and introduction. In this regard more and more urgent is a problem of development of the electronic educational resources adequate to modern educational requirements. Creation and the organization of training courses with use of electronic educational resources in particular on the basis of Internet technologies remains a difficult methodical task.In article the questions connected with development of electronic educational resources for use when studying the substantial line “Information technologies” of a school course of informatics in particular for studying of spreadsheets are considered. Also the analysis of maintenance of a school course and the unified state examination from the point of view of representation of task in him corresponding to the substantial line of studying “Information technologies” on mastering technology of information processing in spreadsheets and the methods of visualization given by means of charts and schedules is carried out.

  12. Carrier for registration of optical images and holographic information

    International Nuclear Information System (INIS)

    Andries, A.; Bivol, V.; Iovu, M.

    2000-01-01

    The invention relates to the field of registration of optical information including the holographic one and may be used in the holography, cinematography, micro- and optical electronics, computer engineering. Summary of the invention consists in, that in the carrier containing a dielectric substrate on which there are placed in sequence the first electrode, photoinjection substrate, registration substrate of the chalcogenide vitreous semiconductor and the second electrode, the photoinjection substrate is fabricated of the monocrystalline germanium of the n-type conductivity and the relation of the registration substrate conductivity, during illumination to the photoinjection substrate conductivity in darkness is 0,001. The technical result consists in increasing the carrier photosensibility and in diffraction effectiveness of the information registered on the carrier

  13. Registration Service

    CERN Multimedia

    GS Department

    2010-01-01

    Following a reorganization in Building 55, please note that the Registration Service is now organised as follows :  Ground floor: access cards (76903). 1st floor : registration of external firms’ personnel (76611 / 76622); car access stickers (76633); biometric registration (79710). Opening hours: 07-30 to 16-00 non-stop. GS-SEM Group General Infrastructure Services Department

  14. Analytical Study of Usage of Electronic Information Resources at Pharmacopoeial Libraries in India

    Directory of Open Access Journals (Sweden)

    Sunil Tyagi

    2014-02-01

    Full Text Available The objective of this study is to know the rate and purpose of the use of e-resource by the scientists at pharmacopoeial libraries in India. Among other things, this study examined the preferences of the scientists toward printed books and journals, electronic information resources, and pattern of using e-resources. Non-probability sampling specially accidental and purposive technique was applied in the collection of primary data through administration of user questionnaire. The sample respondents chosen for the study consists of principle scientific officer, senior scientific officer, scientific officer, and scientific assistant of different division of the laboratories, namely, research and development, pharmaceutical chemistry, pharmacovigilance, pharmacology, pharmacogonosy, and microbiology. The findings of the study reveal the personal experiences and perceptions they have had on practice and research activity using e-resource. The major findings indicate that of the total anticipated participants, 78% indicated that they perceived the ability to use computer for electronic information resources. The data analysis shows that all the scientists belonging to the pharmacopoeial libraries used electronic information resources to address issues relating to drug indexes and compendia, monographs, drugs obtained through online databases, e-journals, and the Internet sources—especially polices by regulatory agencies, contacts, drug promotional literature, and standards.

  15. [Accurate 3D free-form registration between fan-beam CT and cone-beam CT].

    Science.gov (United States)

    Liang, Yueqiang; Xu, Hongbing; Li, Baosheng; Li, Hongsheng; Yang, Fujun

    2012-06-01

    Because the X-ray scatters, the CT numbers in cone-beam CT cannot exactly correspond to the electron densities. This, therefore, results in registration error when the intensity-based registration algorithm is used to register planning fan-beam CT and cone-beam CT. In order to reduce the registration error, we have developed an accurate gradient-based registration algorithm. The gradient-based deformable registration problem is described as a minimization of energy functional. Through the calculus of variations and Gauss-Seidel finite difference method, we derived the iterative formula of the deformable registration. The algorithm was implemented by GPU through OpenCL framework, with which the registration time was greatly reduced. Our experimental results showed that the proposed gradient-based registration algorithm could register more accurately the clinical cone-beam CT and fan-beam CT images compared with the intensity-based algorithm. The GPU-accelerated algorithm meets the real-time requirement in the online adaptive radiotherapy.

  16. Page 170 Use of Electronic Resources by Undergraduates in Two ...

    African Journals Online (AJOL)

    undergraduate students use electronic resources such as NUC virtual library, HINARI, ... web pages articles from magazines, encyclopedias, pamphlets and other .... of Nigerian university libraries have Internet connectivity, some of the system.

  17. Entropy-Based Block Processing for Satellite Image Registration

    Directory of Open Access Journals (Sweden)

    Ikhyun Lee

    2012-11-01

    Full Text Available Image registration is an important task in many computer vision applications such as fusion systems, 3D shape recovery and earth observation. Particularly, registering satellite images is challenging and time-consuming due to limited resources and large image size. In such scenario, state-of-the-art image registration methods such as scale-invariant feature transform (SIFT may not be suitable due to high processing time. In this paper, we propose an algorithm based on block processing via entropy to register satellite images. The performance of the proposed method is evaluated using different real images. The comparative analysis shows that it not only reduces the processing time but also enhances the accuracy.

  18. Model of e-learning with electronic educational resources of new generation

    Directory of Open Access Journals (Sweden)

    A. V. Loban

    2017-01-01

    Full Text Available Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with electronic educational resource of new generation is developed, conditionally decomposed into three basic components: the formalization model of the course in the form of the thesaurusclassifier (“Author of e-resource”, the model of learning as management (“Coordination. Consultation. Control”, the learning model with the thesaurus-classifier (“Student”. Model “Author of e-resource” allows the student to achieve completeness, high degree of didactic elaboration and structuring of the studied material in triples of variants: modules of education information, practical task and control tasks; the result of the student’s (author’s of e-resource activity is the thesaurus-classifier. Model of learning as management is based on the principle of personal orientation of learning in computer environment and determines the logic of interaction between the lecturer and the student when determining the triple of variants individually for each student; organization of a dialogue between the lecturer and the student for consulting purposes; personal control of the student’s success (report generation and iterative search for the concept of the class assignment in the thesaurus-classifier before acquiring the required level of training. Model “Student” makes it possible to concretize the learning tasks in relation to the personality of the student and to the training level achieved; the assumption of the lecturer about the level of training of a

  19. A survey of the use of electronic scientific information resources among medical and dental students

    Directory of Open Access Journals (Sweden)

    Aarnio Matti

    2006-05-01

    Full Text Available Abstract Background To evaluate medical and dental students' utilization of electronic information resources. Methods A web survey sent to 837 students (49.9% responded. Results Twenty-four per cent of medical students and ninteen per cent of dental students searched MEDLINE 2+ times/month for study purposes, and thiry-two per cent and twenty-four per cent respectively for research. Full-text articles were used 2+ times/month by thirty-three per cent of medical and ten per cent of dental students. Twelve per cent of respondents never utilized either MEDLINE or full-text articles. In multivariate models, the information-searching skills among students were significantly associated with use of MEDLINE and full-text articles. Conclusion Use of electronic resources differs among students. Forty percent were non-users of full-text articles. Information-searching skills are correlated with the use of electronic resources, but the level of basic PC skills plays not a major role in using these resources. The student data shows that adequate training in information-searching skills will increase the use of electronic information resources.

  20. Access to electronic information resources by students of federal ...

    African Journals Online (AJOL)

    The paper discusses access to electronic information resources by students of Federal Colleges of Education in Eha-Amufu and Umunze. Descriptive survey design was used to investigate sample of 526 students. Sampling technique used was a Multi sampling technique. Data for the study were generated using ...

  1. Adoption and use of electronic information resources by medical ...

    African Journals Online (AJOL)

    This study investigated the adoption and use of electronic information resources by medical science students of the University of Benin. The descriptive survey research design was adopted for the study and 390 students provided the data. Data collected were analysed with descriptive Statistics(Simple percentage and ...

  2. 21 CFR 710.6 - Notification of registrant; cosmetic product establishment registration number.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Notification of registrant; cosmetic product... OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS VOLUNTARY REGISTRATION OF COSMETIC PRODUCT ESTABLISHMENTS § 710.6 Notification of registrant; cosmetic product establishment registration number. The...

  3. TU-AB-BRA-03: Atlas-Based Algorithms with Local Registration-Goodness Weighting for MRI-Driven Electron Density Mapping

    International Nuclear Information System (INIS)

    Farjam, R; Tyagi, N; Veeraraghavan, H; Apte, A; Zakian, K; Deasy, J; Hunt, M

    2016-01-01

    Purpose: To develop image-analysis algorithms to synthesize CT with accurate electron densities for MR-only radiotherapy of head & neck (H&N) and pelvis anatomies. Methods: CT and 3T-MRI (Philips, mDixon sequence) scans were randomly selected from a pool of H&N (n=11) and pelvis (n=12) anatomies to form an atlas. All MRIs were pre-processed to eliminate scanner and patient-induced intensity inhomogeneities and standardize their intensity histograms. CT and MRI for each patient were then co-registered to construct CT-MRI atlases. For more accurate CT-MR fusion, bone intensities in CT were suppressed to improve the similarity between CT and MRI. For a new patient, all CT-MRI atlases are deformed onto the new patients’ MRI initially. A newly-developed generalized registration error (GRE) metric was then calculated as a measure of local registration accuracy. The synthetic CT value at each point is a 1/GRE-weighted average of CTs from all CT-MR atlases. For evaluation, the mean absolute error (MAE) between the original and synthetic CT (generated in a leave-one-out scheme) was computed. The planning dose from the original and synthetic CT was also compared. Results: For H&N patients, MAE was 67±9, 114±22, and 116±9 HU over the entire-CT, air and bone regions, respectively. For pelvis anatomy, MAE was 47±5 and 146±14 for the entire and bone regions. In comparison with MIRADA medical, an FDA-approved registration tool, we found that our proposed registration strategy reduces MAE by ∼30% and ∼50% over the entire and bone regions, respectively. GRE-weighted strategy further lowers MAE by ∼15% to ∼40%. Our primary dose calculation also showed highly consistent results between the original and synthetic CT. Conclusion: We’ve developed a novel image-analysis technique to synthesize CT for H&N and pelvis anatomies. Our proposed image fusion strategy and GRE metric help generate more accurate synthetic CT using locally more similar atlases (Support: Philips

  4. TU-AB-BRA-03: Atlas-Based Algorithms with Local Registration-Goodness Weighting for MRI-Driven Electron Density Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Farjam, R; Tyagi, N [Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Veeraraghavan, H; Apte, A; Zakian, K; Deasy, J [Memorial Sloan Kettering Cancer Center, New York, NY (United States); Hunt, M [Mem Sloan-Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: To develop image-analysis algorithms to synthesize CT with accurate electron densities for MR-only radiotherapy of head & neck (H&N) and pelvis anatomies. Methods: CT and 3T-MRI (Philips, mDixon sequence) scans were randomly selected from a pool of H&N (n=11) and pelvis (n=12) anatomies to form an atlas. All MRIs were pre-processed to eliminate scanner and patient-induced intensity inhomogeneities and standardize their intensity histograms. CT and MRI for each patient were then co-registered to construct CT-MRI atlases. For more accurate CT-MR fusion, bone intensities in CT were suppressed to improve the similarity between CT and MRI. For a new patient, all CT-MRI atlases are deformed onto the new patients’ MRI initially. A newly-developed generalized registration error (GRE) metric was then calculated as a measure of local registration accuracy. The synthetic CT value at each point is a 1/GRE-weighted average of CTs from all CT-MR atlases. For evaluation, the mean absolute error (MAE) between the original and synthetic CT (generated in a leave-one-out scheme) was computed. The planning dose from the original and synthetic CT was also compared. Results: For H&N patients, MAE was 67±9, 114±22, and 116±9 HU over the entire-CT, air and bone regions, respectively. For pelvis anatomy, MAE was 47±5 and 146±14 for the entire and bone regions. In comparison with MIRADA medical, an FDA-approved registration tool, we found that our proposed registration strategy reduces MAE by ∼30% and ∼50% over the entire and bone regions, respectively. GRE-weighted strategy further lowers MAE by ∼15% to ∼40%. Our primary dose calculation also showed highly consistent results between the original and synthetic CT. Conclusion: We’ve developed a novel image-analysis technique to synthesize CT for H&N and pelvis anatomies. Our proposed image fusion strategy and GRE metric help generate more accurate synthetic CT using locally more similar atlases (Support: Philips

  5. Where Do Electronic Books Fit in the College Research Arsenal of Resources?

    Science.gov (United States)

    Barbier, Patricia

    2007-01-01

    Student use of electronic books has become an accepted supplement to traditional resources. Student use and satisfaction was monitored through an online course discussion board. Increased use of electronic books indicate this service is an accepted supplement to the print book collection.

  6. 16 CFR 1130.8 - Requirements for Web site registration or alternative e-mail registration.

    Science.gov (United States)

    2010-01-01

    ... registration. (a) Link to registration page. The manufacturer's Web site, or other Web site established for the... web page that goes directly to “Product Registration.” (b) Purpose statement. The registration page... registration page. The Web site registration page shall request only the consumer's name, address, telephone...

  7. Overlay improvement by exposure map based mask registration optimization

    Science.gov (United States)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density

  8. Clinical trial registration and reporting: a survey of academic organizations in the United States.

    Science.gov (United States)

    Mayo-Wilson, Evan; Heyward, James; Keyes, Anthony; Reynolds, Jesse; White, Sarah; Atri, Nidhi; Alexander, G Caleb; Omar, Audrey; Ford, Daniel E

    2018-05-02

    Many clinical trials conducted by academic organizations are not published, or are not published completely. Following the US Food and Drug Administration Amendments Act of 2007, "The Final Rule" (compliance date April 18, 2017) and a National Institutes of Health policy clarified and expanded trial registration and results reporting requirements. We sought to identify policies, procedures, and resources to support trial registration and reporting at academic organizations. We conducted an online survey from November 21, 2016 to March 1, 2017, before organizations were expected to comply with The Final Rule. We included active Protocol Registration and Results System (PRS) accounts classified by ClinicalTrials.gov as a "University/Organization" in the USA. PRS administrators manage information on ClinicalTrials.gov. We invited one PRS administrator to complete the survey for each organization account, which was the unit of analysis. Eligible organization accounts (N = 783) included 47,701 records (e.g., studies) in August 2016. Participating organizations (366/783; 47%) included 40,351/47,701 (85%) records. Compared with other organizations, Clinical and Translational Science Award (CTSA) holders, cancer centers, and large organizations were more likely to participate. A minority of accounts have a registration (156/366; 43%) or results reporting policy (129/366; 35%). Of those with policies, 15/156 (11%) and 49/156 (35%) reported that trials must be registered before institutional review board approval is granted or before beginning enrollment, respectively. Few organizations use computer software to monitor compliance (68/366; 19%). One organization had penalized an investigator for non-compliance. Among the 287/366 (78%) accounts reporting that they allocate staff to fulfill ClinicalTrials.gov registration and reporting requirements, the median number of full-time equivalent staff is 0.08 (interquartile range = 0.02-0.25). Because of non-response and

  9. Constrained non-rigid registration for whole body image registration: method and validation

    Science.gov (United States)

    Li, Xia; Yankeelov, Thomas E.; Peterson, Todd E.; Gore, John C.; Dawant, Benoit M.

    2007-03-01

    3D intra- and inter-subject registration of image volumes is important for tasks that include measurements and quantification of temporal/longitudinal changes, atlas-based segmentation, deriving population averages, or voxel and tensor-based morphometry. A number of methods have been proposed to tackle this problem but few of them have focused on the problem of registering whole body image volumes acquired either from humans or small animals. These image volumes typically contain a large number of articulated structures, which makes registration more difficult than the registration of head images, to which the vast majority of registration algorithms have been applied. To solve this problem, we have previously proposed an approach, which initializes an intensity-based non-rigid registration algorithm with a point based registration technique [1, 2]. In this paper, we introduce new constraints into our non-rigid registration algorithm to prevent the bones from being deformed inaccurately. Results we have obtained show that the new constrained algorithm leads to better registration results than the previous one.

  10. Mass preserving image registration

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2010-01-01

    The paper presents results the mass preserving image registration method in the Evaluation of Methods for Pulmonary Image Registration 2010 (EMPIRE10) Challenge. The mass preserving image registration algorithm was applied to the 20 image pairs. Registration was evaluated using four different...

  11. Registration of Space Objects

    Science.gov (United States)

    Schmidt-Tedd, Bernhard

    2017-07-01

    Space objects are subject to registration in order to allocate "jurisdiction and control" over those objects in the sovereign-free environment of outer space. This approach is similar to the registration of ships in view of the high sea and for aircrafts with respect to the international airspace. Registration is one of the basic principles of space law, starting with UN General Assembly Resolution 1721 B (XVI) of December 20, 1961, followed by Resolution 1962 (XVIII) of December 13, 1963, then formulated in Article VIII of the Outer Space Treaty of 1967 and as specified in the Registration Convention of 1975. Registration of space objects can be seen today as a principle of customary international law, relevant for each spacefaring state. Registration is divided into a national and an international level. The State Party establishes a national registry for its space objects, and those registrations have to be communicated via diplomatic channel to the UN Register of space objects. This UN Register is handled by the UN Office for Outer Space Affairs (UNOOSA) and is an open source of information for space objects worldwide. Registration is linked to the so-called launching state of the relevant space object. There might be more than one launching state for the specific launch event, but only one state actor can register a specific space object. The state of registry gains "jurisdiction and control" over the space object and therefore no double registration is permissible. Based on the established UN Space Law, registration practice was subject to some adaptions due to technical developments and legal challenges. After the privatization of the major international satellite organizations, a number of non-registrations had to be faced. The state actors reacted with the UN Registration Practice Resolution of 2007 as elaborated in the Legal Subcommittee of UNCOPUOS, the Committee for the Peaceful Use of Outer Space. In this context an UNOOSA Registration Information

  12. Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College

    Science.gov (United States)

    Hulseberg, Anna; Monson, Sarah

    2009-01-01

    Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…

  13. REVIEW OF MOODLE PLUGINS FOR DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES FROM LANGUAGE DISCIPLINES

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2015-09-01

    Full Text Available Today the problem of designing multimedia electronic educational resources from language disciplines in Moodle is very important. This system has a lot of different, powerful resources, plugins to facilitate the learning of students with language disciplines. This article presents an overview and comparative analysis of the five Moodle plugins for designing multimedia electronic educational resources from language disciplines. There have been considered their key features and functionality in order to choose the best for studying language disciplines in the Moodle. Plugins are compared by a group of experts according to the criteria: efficiency, functionality and easy use. For a comparative analysis of the plugins it is used the analytic hierarchy process.

  14. 21 CFR 1301.36 - Suspension or revocation of registration; suspension of registration pending final order...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Suspension or revocation of registration; suspension of registration pending final order; extension of registration pending final order. 1301.36... registration pending final order; extension of registration pending final order. (a) For any registration...

  15. 21 CFR 710.8 - Misbranding by reference to registration or to registration number.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) COSMETICS VOLUNTARY REGISTRATION OF COSMETIC PRODUCT ESTABLISHMENTS § 710.8 Misbranding by reference to registration or to registration number. Registration of a cosmetic product... products by the Food and Drug Administration. Any representation in labeling or advertising that creates an...

  16. Modern ICT Tools: Online Electronic Resources Sharing Using Web ...

    African Journals Online (AJOL)

    Modern ICT Tools: Online Electronic Resources Sharing Using Web 2.0 and Its Implications For Library And Information Practice In Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more ...

  17. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2017-10-01

    Full Text Available The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system should be assessed. Developed a model for the development of the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system, which is based on the main scientific approaches, used in adult education, and consists of five blocks: target, informative, technological, diagnostic and effective.

  18. Developing Humanities Collections in the Digital Age: Exploring Humanities Faculty Engagement with Electronic and Print Resources

    Science.gov (United States)

    Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica

    2014-01-01

    This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…

  19. 32 CFR 1615.1 - Registration.

    Science.gov (United States)

    2010-07-01

    ... registration card or other method of registration prescribed by the Director of Selective Service by a person... the records (master computer file) of the Selective Service System. Registration is completed when... Director include completing a Selective Service Registration Card at a classified Post Office, registration...

  20. 37 CFR 202.20 - Deposit of copies and phonorecords for copyright registration.

    Science.gov (United States)

    2010-07-01

    ... published in both hard copy, i.e., in a physically tangible format, and also in an electronic format, the current Library of Congress Best Edition Statement requirements pertaining to the hard copy format apply... registration in digital formats. A ‘complete’ electronically filed work is one which is embodied in a digital...

  1. Registration performance on EUV masks using high-resolution registration metrology

    Science.gov (United States)

    Steinert, Steffen; Solowan, Hans-Michael; Park, Jinback; Han, Hakseung; Beyer, Dirk; Scherübl, Thomas

    2016-10-01

    Next-generation lithography based on EUV continues to move forward to high-volume manufacturing. Given the technical challenges and the throughput concerns a hybrid approach with 193 nm immersion lithography is expected, at least in the initial state. Due to the increasing complexity at smaller nodes a multitude of different masks, both DUV (193 nm) and EUV (13.5 nm) reticles, will then be required in the lithography process-flow. The individual registration of each mask and the resulting overlay error are of crucial importance in order to ensure proper functionality of the chips. While registration and overlay metrology on DUV masks has been the standard for decades, this has yet to be demonstrated on EUV masks. Past generations of mask registration tools were not necessarily limited in their tool stability, but in their resolution capabilities. The scope of this work is an image placement investigation of high-end EUV masks together with a registration and resolution performance qualification. For this we employ a new generation registration metrology system embedded in a production environment for full-spec EUV masks. This paper presents excellent registration performance not only on standard overlay markers but also on more sophisticated e-beam calibration patterns.

  2. 75 FR 70973 - Registration of Foreign Boards of Trade

    Science.gov (United States)

    2010-11-19

    ... prospectively to facilitate direct access to the electronic trading system of a foreign board of trade by its U... Trade; Proposed Rule #0;#0;Federal Register / Vol. 75 , No. 223 / Friday, November 19, 2010 / Proposed... Registration of Foreign Boards of Trade AGENCY: Commodity Futures Trading Commission. ACTION: Notice of...

  3. Information from the Registration Service

    CERN Multimedia

    GS Department

    2011-01-01

    Please note that the Registration Service (Bldg 55-1st floor) will be exceptionally open during the annual end of year closure from 10:00 to 12:00 on the following days: 22, 23, 26, 27,28, 29 et 30 December 2011 and 2,3, et 4 January 2012. All the activities related to the Registration Service will be operational: registration for contractors’ personnel; registrations for professional visits; access cards; car stickers; biometric registration. The Registration Service

  4. Electronic resource management systems a workflow approach

    CERN Document Server

    Anderson, Elsa K

    2014-01-01

    To get to the bottom of a successful approach to Electronic Resource Management (ERM), Anderson interviewed staff at 11 institutions about their ERM implementations. Among her conclusions, presented in this issue of Library Technology Reports, is that grasping the intricacies of your workflow-analyzing each step to reveal the gaps and problems-at the beginning is crucial to selecting and implementing an ERM. Whether the system will be used to fill a gap, aggregate critical data, or replace a tedious manual process, the best solution for your library depends on factors such as your current soft

  5. Electronic Resource Management System. Vernetzung von Lizenzinformationen

    Directory of Open Access Journals (Sweden)

    Michaela Selbach

    2014-12-01

    Full Text Available In den letzten zehn Jahren spielen elektronische Ressourcen im Bereich der Erwerbung eine zunehmend wichtige Rolle: Eindeutig lässt sich hier ein Wandel in den Bibliotheken (fort vom reinen Printbestand zu immer größeren E-Only-Beständen feststellen. Die stetig wachsende Menge an E-Ressourcen und deren Heterogenität stellt Bibliotheken vor die Herausforderung, die E-Ressourcen effizient zu verwalten. Nicht nur Bibliotheken, sondern auch verhandlungsführende Institutionen von Konsortial- und Allianzlizenzen benötigen ein geeignetes Instrument zur Verwaltung von Lizenzinformationen, welches den komplexen Anforderungen moderner E-Ressourcen gerecht wird. Die Deutsche Forschungsgemeinschaft (DFG unterstützt ein Projekt des Hochschulbibliothekszentrums des Landes Nordrhein-Westfalen (hbz, der Universitätsbibliothek Freiburg, der Verbundzentrale des Gemeinsamen Bibliotheksverbundes (GBV und der Universitätsbibliothek Frankfurt, in dem ein bundesweit verfügbares Electronic Ressource Managementsystem (ERMS aufgebaut werden soll. Ein solches ERMS soll auf Basis einer zentralen Knowledge Base eine einheitliche Nutzung von Daten zur Lizenzverwaltung elektronischer Ressourcen auf lokaler, regionaler und nationaler Ebene ermöglichen. Statistische Auswertungen, Rechteverwaltung für alle angeschlossenen Bibliotheken, kooperative Datenpflege sowie ein über standardisierte Schnittstellen geführter Datenaustausch stehen bei der Erarbeitung der Anforderungen ebenso im Fokus wie die Entwicklung eines Daten- und Funktionsmodells. In the last few years the importance of electronic resources in library acquisitions has increased significantly. There has been a shift from mere print holdings to both e- and print combinations and even e-only subscriptions. This shift poses a double challenge for libraries: On the one hand they have to provide their e-resource collections to library users in an appealing way, on the other hand they have to manage these

  6. The Electron Microscopy Outreach Program: A Web-based resource for research and education.

    Science.gov (United States)

    Sosinsky, G E; Baker, T S; Hand, G; Ellisman, M H

    1999-01-01

    We have developed a centralized World Wide Web (WWW)-based environment that serves as a resource of software tools and expertise for biological electron microscopy. A major focus is molecular electron microscopy, but the site also includes information and links on structural biology at all levels of resolution. This site serves to help integrate or link structural biology techniques in accordance with user needs. The WWW site, called the Electron Microscopy (EM) Outreach Program (URL: http://emoutreach.sdsc.edu), provides scientists with computational and educational tools for their research and edification. In particular, we have set up a centralized resource containing course notes, references, and links to image analysis and three-dimensional reconstruction software for investigators wanting to learn about EM techniques either within or outside of their fields of expertise. Copyright 1999 Academic Press.

  7. Technical Communicator: A New Model for the Electronic Resources Librarian?

    Science.gov (United States)

    Hulseberg, Anna

    2016-01-01

    This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…

  8. Effect of UK policy on medical migration: a time series analysis of physician registration data.

    Science.gov (United States)

    Blacklock, Claire; Heneghan, Carl; Mant, David; Ward, Alison M

    2012-09-25

    Economically developed countries have recruited large numbers of overseas health workers to fill domestic shortages. Recognition of the negative impact this can have on health care in developing countries led the United Kingdom Department of Health to issue a Code of Practice for National Health Service (NHS) employers in 1999 providing ethical guidance on international recruitment. Case reports suggest this guidance had limited influence in the context of other NHS policy priorities. The temporal association between trends in new professional registrations from doctors qualifying overseas and relevant United Kingdom government policy is reported. Government policy documents were identified by a literature review; further information was obtained, when appropriate, through requests made under the Freedom of Information Act. Data on new professional registration of doctors were obtained from the General Medical Council (GMC). New United Kingdom professional registrations by doctors trained in Africa and south Asia more than doubled from 3105 in 2001 to 7343 in 2003, as NHS Trusts sought to achieve recruitment targets specified in the 2000 NHS Plan; this occurred despite ethical guidance to avoid active recruitment of doctors from resource-poor countries. Registration of such doctors declined subsequently, but in response to other government policy initiatives. A fall in registration of South African-trained doctors from 3206 in 2003 to 4 in 2004 followed a Memorandum of Understanding with South Africa signed in 2003. Registrations from India and Pakistan fell from a peak of 4626 in 2004 to 1169 in 2007 following changes in United Kingdom immigration law in 2005 and 2006. Since 2007, registration of new doctors trained outside the European Economic Area has remained relatively stable, but in 2010 the United Kingdom still registered 722 new doctors trained in Africa and 1207 trained in India and Pakistan. Ethical guidance was ineffective in preventing mass

  9. Study time within pre-registration nurse education: A critical review of the literature.

    Science.gov (United States)

    Barker, Caroline; King, Nigel; Snowden, Michael; Ousey, Karen

    2016-06-01

    Pre-registration nursing students throughout the United Kingdom (UK) are required to complete a minimum number of theory hours within the course. Anecdotal evidence suggests that students are required to attend campus for approximately fifty percent of the theory hours. The remaining theory hours are often labelled as 'study time' in which students are not required to attend campus. There is a general assumption amongst many academics that all students are prepared and motivated to direct their learning and therefore use this time to study. However some students chose to work during this time and many have dependents. Considering the increasing cost of nurse education combined with the government cuts to student bursaries in England it is timely to review the literature to determine how study time is used within pre-registration nurse education. To present a critical review of the literature pertaining to study time in pre-registration nurse education. An integrative review of the literature. A search of electronic databases: Cumulative Index to Nursing and Allied Health (CINAHL); Cochrane; Medline; Science Direct; Blackwell Synergy; Electronic Journals Service (EJS); Scopus; Taylor & Francis, Eric and Routledge Wiley was undertaken. The inclusion criteria consisted of peer reviewed primary research, discussion papers, unpublished doctoral theses' and editorial papers directly related to the key words and nurse education published in English. Twelve papers were included in the review. Analysis of the papers led to the development of two themes: orientation to self-directed learning (SDL) and preparation for SDL. The literature demonstrates that pre-registration nursing students lack the necessary skills for SDL. There is a lack of research on how study time is used within pre-registration nurse education. This calls for empirical research to fully explore how nursing students and lecturers perceive study time within pre-registration nursing curricula. Crown

  10. Assessment of rigid multi-modality image registration consistency using the multiple sub-volume registration (MSR) method

    International Nuclear Information System (INIS)

    Ceylan, C; Heide, U A van der; Bol, G H; Lagendijk, J J W; Kotte, A N T J

    2005-01-01

    Registration of different imaging modalities such as CT, MRI, functional MRI (fMRI), positron (PET) and single photon (SPECT) emission tomography is used in many clinical applications. Determining the quality of any automatic registration procedure has been a challenging part because no gold standard is available to evaluate the registration. In this note we present a method, called the 'multiple sub-volume registration' (MSR) method, for assessing the consistency of a rigid registration. This is done by registering sub-images of one data set on the other data set, performing a crude non-rigid registration. By analysing the deviations (local deformations) of the sub-volume registrations from the full registration we get a measure of the consistency of the rigid registration. Registration of 15 data sets which include CT, MR and PET images for brain, head and neck, cervix, prostate and lung was performed utilizing a rigid body registration with normalized mutual information as the similarity measure. The resulting registrations were classified as good or bad by visual inspection. The resulting registrations were also classified using our MSR method. The results of our MSR method agree with the classification obtained from visual inspection for all cases (p < 0.02 based on ANOVA of the good and bad groups). The proposed method is independent of the registration algorithm and similarity measure. It can be used for multi-modality image data sets and different anatomic sites of the patient. (note)

  11. 21 CFR 1301.52 - Termination of registration; transfer of registration; distribution upon discontinuance of business.

    Science.gov (United States)

    2010-04-01

    ... discontinues business or professional practice. Any registrant who ceases legal existence or discontinues... registration; distribution upon discontinuance of business. 1301.52 Section 1301.52 Food and Drugs DRUG... of registration; transfer of registration; distribution upon discontinuance of business. (a) Except...

  12. Electronic Submissions of Pesticide Applications

    Science.gov (United States)

    Applications for pesticide registration can be submitted electronically, including forms, studies, and draft product labeling. Applicants need not submit multiple electronic copies of any pieces of their applications.

  13. End of paper registration forms for new computer users

    CERN Multimedia

    2007-01-01

    As of 3rd December 2007 it will be possible for new users to sign the Computer Centre User Registration Form electronically. As before, new users will still need to go to their computing group administrator, who will make the electronic request for account creation using CRA and give the new user his or her initial password. The difference is that the requested accounts will be created and usable almost immediately. Users will then have 3 days within which they must go to the web page http://cern.ch/cernaccount and click on ‘New User’. They will be required to follow a short computer security awareness training course, read the CERN Computing Rules and then confirm that they accept the rules. If this is not completed within 3 days all their computer accounts will be blocked and they will have to contact the Helpdesk to unblock their accounts and get a second chance to complete the registration. During the introductory phase the existing paper forms will also be accepted ...

  14. MODEL OF AN ELECTRONIC EDUCATIONAL RESOURCE OF NEW GENERATION

    Directory of Open Access Journals (Sweden)

    Anatoliy V. Loban

    2016-01-01

    Full Text Available The mathematical structure of the modular architecture of an electronic educational resource (EER of new generation, which allows to decompose the process of studying the subjects of the course at a hierarchically ordered set of data (knowledge and procedures for manipulating them, to determine the roles of participants of process of training of and technology the development and use of EOR in the study procrate.

  15. 17 CFR 275.203-1 - Application for investment adviser registration.

    Science.gov (United States)

    2010-04-01

    ... must file electronically with the Investment Adviser Registration Depository (IARD), unless you have... you have paid the filing fee. [65 FR 57448, Sept. 22, 2000; 65 FR 81737, Dec. 27, 2000; 68 FR 42248... EXCHANGE COMMISSION (CONTINUED) RULES AND REGULATIONS, INVESTMENT ADVISERS ACT OF 1940 § 275.203-1...

  16. Performance evaluation of 2D image registration algorithms with the numeric image registration and comparison platform

    International Nuclear Information System (INIS)

    Gerganov, G.; Kuvandjiev, V.; Dimitrova, I.; Mitev, K.; Kawrakow, I.

    2012-01-01

    The objective of this work is to present the capabilities of the NUMERICS web platform for evaluation of the performance of image registration algorithms. The NUMERICS platform is a web accessible tool which provides access to dedicated numerical algorithms for registration and comparison of medical images (http://numerics.phys.uni-sofia.bg). The platform allows comparison of noisy medical images by means of different types of image comparison algorithms, which are based on statistical tests for outliers. The platform also allows 2D image registration with different techniques like Elastic Thin-Plate Spline registration, registration based on rigid transformations, affine transformations, as well as non-rigid image registration based on Mobius transformations. In this work we demonstrate how the platform can be used as a tool for evaluation of the quality of the image registration process. We demonstrate performance evaluation of a deformable image registration technique based on Mobius transformations. The transformations are applied with appropriate cost functions like: Mutual information, Correlation coefficient, Sum of Squared Differences. The accent is on the results provided by the platform to the user and their interpretation in the context of the performance evaluation of 2D image registration. The NUMERICS image registration and image comparison platform provides detailed statistical information about submitted image registration jobs and can be used to perform quantitative evaluation of the performance of different image registration techniques. (authors)

  17. How precise is manual CT-MRI registration for cranial radiotherapy planning?

    International Nuclear Information System (INIS)

    Mosleh-Shirazi, M. A.; South, P. C.

    2005-01-01

    Manual fusion is a readily available image registration technique that does not require matching algorithms. The operator performs rigid-body transformations interactively. The precision of Manual fusion (as implemented on the Philips Pinnacle treatment planning system) was required for cranial CT-MR images used in radiotherapy planning for typical centrally located planning target volumes . Materials and Methods: A multi-stage Manual fusion procedure was developed which 11 observers followed to match the head contour, bones, soft tissues and contoured structures for 5 patient image-sets. Registration parameters were calculated by solving the transformation matrix following a consistent order of translations (T) and rotations (R). The mean position of centre of each planning target volumes averaged over all observers was used as the reference. The effect of mis registration on the planning target volumes co-ordinates and the volume increase resulting from application of a margin for registration uncertainty were calculated. Results: Mean intra- and inter-observer T/R SDs were 0.5 mm/ 0.4 d ig a nd 1.1 mm/ 1.0 d ig , respectively. Mean intra- and inter-observer registration error (3D distance of each planning target volumes centre from the mean position for all observers) was 0.7 ±0.3 mm (1 SD) and 1.6±0.7 mm respectively, the latter reducing to 1.4±0.6 mm excluding the 3 least experienced operators. A subsequent 2 mm margin for mis registration on average increased the planning target volume by 27%. Conclusion: Moderately trained operators produced clinically acceptable results while experienced operators improved the precision. Manual fusion still has an important role in the registration of cranial CT and MR images for radiotherapy planning especially for under-resourced centers

  18. Image registration with uncertainty analysis

    Science.gov (United States)

    Simonson, Katherine M [Cedar Crest, NM

    2011-03-22

    In an image registration method, edges are detected in a first image and a second image. A percentage of edge pixels in a subset of the second image that are also edges in the first image shifted by a translation is calculated. A best registration point is calculated based on a maximum percentage of edges matched. In a predefined search region, all registration points other than the best registration point are identified that are not significantly worse than the best registration point according to a predetermined statistical criterion.

  19. The plant virus microscope image registration method based on mismatches removing.

    Science.gov (United States)

    Wei, Lifang; Zhou, Shucheng; Dong, Heng; Mao, Qianzhuo; Lin, Jiaxiang; Chen, Riqing

    2016-01-01

    The electron microscopy is one of the major means to observe the virus. The view of virus microscope images is limited by making specimen and the size of the camera's view field. To solve this problem, the virus sample is produced into multi-slice for information fusion and image registration techniques are applied to obtain large field and whole sections. Image registration techniques have been developed in the past decades for increasing the camera's field of view. Nevertheless, these approaches typically work in batch mode and rely on motorized microscopes. Alternatively, the methods are conceived just to provide visually pleasant registration for high overlap ratio image sequence. This work presents a method for virus microscope image registration acquired with detailed visual information and subpixel accuracy, even when overlap ratio of image sequence is 10% or less. The method proposed focus on the correspondence set and interimage transformation. A mismatch removal strategy is proposed by the spatial consistency and the components of keypoint to enrich the correspondence set. And the translation model parameter as well as tonal inhomogeneities is corrected by the hierarchical estimation and model select. In the experiments performed, we tested different registration approaches and virus images, confirming that the translation model is not always stationary, despite the fact that the images of the sample come from the same sequence. The mismatch removal strategy makes building registration of virus microscope images at subpixel accuracy easier and optional parameters for building registration according to the hierarchical estimation and model select strategies make the proposed method high precision and reliable for low overlap ratio image sequence. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. A Remote Registration Based on MIDAS

    Science.gov (United States)

    JIN, Xin

    2017-04-01

    We often need for software registration to protect the interests of the software developers. This article narrated one kind of software long-distance registration technology. The registration method is: place the registration information in a database table, after the procedure starts in check table registration information, if it has registered then the procedure may the normal operation; Otherwise, the customer must input the sequence number and registers through the network on the long-distance server. If it registers successfully, then records the registration information in the database table. This remote registration method can protect the rights of software developers.

  1. Image Registration: A Necessary Evil

    Science.gov (United States)

    Bell, James; McLachlan, Blair; Hermstad, Dexter; Trosin, Jeff; George, Michael W. (Technical Monitor)

    1995-01-01

    Registration of test and reference images is a key component of nearly all PSP data reduction techniques. This is done to ensure that a test image pixel viewing a particular point on the model is ratioed by the reference image pixel which views the same point. Typically registration is needed to account for model motion due to differing airloads when the wind-off and wind-on images are taken. Registration is also necessary when two cameras are used for simultaneous acquisition of data from a dual-frequency paint. This presentation will discuss the advantages and disadvantages of several different image registration techniques. In order to do so, it is necessary to propose both an accuracy requirement for image registration and a means for measuring the accuracy of a particular technique. High contrast regions in the unregistered images are most sensitive to registration errors, and it is proposed that these regions be used to establish the error limits for registration. Once this is done, the actual registration error can be determined by locating corresponding points on the test and reference images, and determining how well a particular registration technique matches them. An example of this procedure is shown for three transforms used to register images of a semispan model. Thirty control points were located on the model. A subset of the points were used to determine the coefficients of each registration transform, and the error with which each transform aligned the remaining points was determined. The results indicate the general superiority of a third-order polynomial over other candidate transforms, as well as showing how registration accuracy varies with number of control points. Finally, it is proposed that image registration may eventually be done away with completely. As more accurate image resection techniques and more detailed model surface grids become available, it will be possible to map raw image data onto the model surface accurately. Intensity

  2. TU-B-19A-01: Image Registration II: TG132-Quality Assurance for Image Registration

    International Nuclear Information System (INIS)

    Brock, K; Mutic, S

    2014-01-01

    AAPM Task Group 132 was charged with a review of the current approaches and solutions for image registration in radiotherapy and to provide recommendations for quality assurance and quality control of these clinical processes. As the results of image registration are always used as the input of another process for planning or delivery, it is important for the user to understand and document the uncertainty associate with the algorithm in general and the Result of a specific registration. The recommendations of this task group, which at the time of abstract submission are currently being reviewed by the AAPM, include the following components. The user should understand the basic image registration techniques and methods of visualizing image fusion. The disclosure of basic components of the image registration by commercial vendors is critical in this respect. The physicists should perform end-to-end tests of imaging, registration, and planning/treatment systems if image registration is performed on a stand-alone system. A comprehensive commissioning process should be performed and documented by the physicist prior to clinical use of the system. As documentation is important to the safe implementation of this process, a request and report system should be integrated into the clinical workflow. Finally, a patient specific QA practice should be established for efficient evaluation of image registration results. The implementation of these recommendations will be described and illustrated during this educational session. Learning Objectives: Highlight the importance of understanding the image registration techniques used in their clinic. Describe the end-to-end tests needed for stand-alone registration systems. Illustrate a comprehensive commissioning program using both phantom data and clinical images. Describe a request and report system to ensure communication and documentation. Demonstrate an clinically-efficient patient QA practice for efficient evaluation of image

  3. Accelerated gradient-based free form deformable registration for online adaptive radiotherapy

    International Nuclear Information System (INIS)

    Yu, Gang; Yang, Guanyu; Shu, Huazhong; Li, Baosheng; Liang, Yueqiang; Yin, Yong; Li, Dengwang

    2015-01-01

    The registration of planning fan-beam computed tomography (FBCT) and daily cone-beam CT (CBCT) is a crucial step in adaptive radiation therapy. The current intensity-based registration algorithms, such as Demons, may fail when they are used to register FBCT and CBCT, because the CT numbers in CBCT cannot exactly correspond to the electron densities. In this paper, we investigated the effects of CBCT intensity inaccuracy on the registration accuracy and developed an accurate gradient-based free form deformation algorithm (GFFD). GFFD distinguishes itself from other free form deformable registration algorithms by (a) measuring the similarity using the 3D gradient vector fields to avoid the effect of inconsistent intensities between the two modalities; (b) accommodating image sampling anisotropy using the local polynomial approximation-intersection of confidence intervals (LPA-ICI) algorithm to ensure a smooth and continuous displacement field; and (c) introducing a ‘bi-directional’ force along with an adaptive force strength adjustment to accelerate the convergence process. It is expected that such a strategy can decrease the effect of the inconsistent intensities between the two modalities, thus improving the registration accuracy and robustness. Moreover, for clinical application, the algorithm was implemented by graphics processing units (GPU) through OpenCL framework. The registration time of the GFFD algorithm for each set of CT data ranges from 8 to 13 s. The applications of on-line adaptive image-guided radiation therapy, including auto-propagation of contours, aperture-optimization and dose volume histogram (DVH) in the course of radiation therapy were also studied by in-house-developed software. (paper)

  4. Registration factors that limit international mobility of people holding physiotherapy qualifications: A systematic review.

    Science.gov (United States)

    Foo, Jonathan S; Storr, Michael; Maloney, Stephen

    2016-06-01

    There is no enforced international standardisation of the physiotherapy profession. Thus, registration is used in many countries to maintain standards of care and to protect the public. However, registration may also limit international workforce mobility. What is known about the professional registration factors that may limit the international mobility of people holding physiotherapy qualifications? Systematic review using an electronic database search and hand searching of the World Confederation for Physical Therapy and International Network of Physiotherapy Regulatory Authorities websites. Analysis was conducted using thematic analysis. 10 articles and eight websites were included from the search strategy. Data is representative of high-income English speaking countries. Four themes emerged regarding limitations to professional mobility: practice context, qualification recognition, verification of fitness to practice, and incidental limitations arising from the registration process. Professional mobility is limited by differences in physiotherapy education programmes, resulting in varying standards of competency. Thus, it is often necessary to verify clinical competencies through assessments, as well as determining professional attributes and ability to apply competencies in a different practice context, as part of the registration process. There has been little evaluation of registration practices, and at present, there is a need to re-evaluate current registration processes to ensure they are efficient and effective, thereby enhancing workforce mobility. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. GUIDELINES FOR EVALUATION OF PSYCHOLOGICAL AND PEDAGOGICAL QUALITY CHARACTERISTICS OF ELECTRONIC EDUCATIONAL RESOURCES

    Directory of Open Access Journals (Sweden)

    Galina P. Lavrentieva

    2014-05-01

    Full Text Available The article highlights the causes of insufficient effective use of electronic learning resources and sets out the guidelines on ways to solve the aforementioned problems. The set of didactic, methodical, psychological, pedagogical, design and ergonomic quality requirements is considered for evaluation, selection and application of information and communication technologies in the educational process. The most appropriate mechanisms for the ICT introduction into the learning process are disclosed as it should meet the specific learning needs of the student and the objectives of the educational process. The guidance for psycho-educational assessment of quality of electronic educational resources is provided. It is argued that the effectiveness of the ICT use is to be improved by means of quality evaluation mechanisms involved into the educational process.

  6. Availability, Use and Constraints to Use of Electronic Information Resources by Postgraduates Students at the University of Ibadan

    Directory of Open Access Journals (Sweden)

    Dare Samuel Adeleke

    2017-12-01

    Full Text Available Availability, awareness and use of electronic resources provide access to authoritative, reliable, accurate and timely access to information. The use of electronic information resources (EIRs can enable innovation in teaching and increase timeliness in research of postgraduate students which will eventual result into encouragement of the expected research-led enquiry in this digital age. The study adopted a descriptive survey design. Samples of 300 of postgraduate students within seven out 13 Faculties were randomly selected. Data were collected using questionnaire designed to elicit response from respondents and data were analyzed using descriptive statistics methods percentages, mean, and standard deviation. Results indicated that internet was ranked most available and used in the university. Low level of usage of electronic resources, in particular, full texts data bases is linked to a number of constraints: Interrupted power supply was ranked highest among other factors as speed and capacity of computers, retrieval of records with high recall and low precision, retrieving records relevant to information need, lack of knowledge of search techniques to retrieve information effectively, non possession of requisite IT skills and problems accessing the internet. The study recommended that usage of electronic resources be made compulsory, intensifying awareness campaigns concerning the availability, training on use of electronic resources and the problem of power outage be addressed.

  7. Registration of clinical volumes to beams-eye-view images for real-time tracking

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Jonathan H.; Rottmann, Joerg; Lewis, John H.; Mishra, Pankaj; Berbeco, Ross I., E-mail: rberbeco@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Keall, Paul J. [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney, New South Wales 2006 (Australia)

    2014-12-15

    Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

  8. A Study on Developing Evaluation Criteria for Electronic Resources in Evaluation Indicators of Libraries

    Science.gov (United States)

    Noh, Younghee

    2010-01-01

    This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…

  9. Challenging an immediate suspension of a DEA registration: is it time for a new tact?

    Science.gov (United States)

    Behr, Douglas J

    2014-01-01

    A Drug Enforcement Administration ("DEA") registration is not only a necessity, but also an invaluable commodity for doctors, pharmacists, hospitals and drug wholesalers who prescribe, stock, and distribute controlled substances. While the DEA may only suspend a registration by issuing an immediate suspension order ("ISO) after an ex parte finding of "imminent danger to the public health or safety," the law fails to explicitly protect the registrant by way of a post-suspension hearing on the ISO, despite the registrant's constitutionally protected property interest in the registration. A registrant has only two procedural options--which are often unsuccessful--to challenge the ISO: endure a long and arduous administrative review proceeding or petition the court for a "not-so-easily proven" injunction, all the while the suspension remains in effect and the controlled substance business operations cease. Accordingly, a suspension of the registration may be certain death to doctors and pharmacists without the financial means to operate the business in the absence of the registration. Because the DEA registration is a constitutionally-protected interest, there is a better way to challenge the suspension. The Supreme Court has held that once a license is issued, the continued possession of it is essential to the registrant's livelihood. Therefore suspension or revocation of such a protected interest requires due process. Due-process hearings, while varied, will provide the necessary avenues of review to provide a fair review of the justification of the suspension and its continuance, i.e., whether there truly is imminent danger to public health or safety and whether the suspension is overbroad and should be limited. To date, this thesis remains to be tested and awaits a petitioner with a justiciable claim and the financial resources to challenge the DEA in court. But in the field of DEA ISO challenges, it is time for a new tact!

  10. The hidden KPI registration accuracy.

    Science.gov (United States)

    Shorrosh, Paul

    2011-09-01

    Determining the registration accuracy rate is fundamental to improving revenue cycle key performance indicators. A registration quality assurance (QA) process allows errors to be corrected before bills are sent and helps registrars learn from their mistakes. Tools are available to help patient access staff who perform registration QA manually.

  11. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    OpenAIRE

    Anton M. Avramchuk

    2017-01-01

    The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing ...

  12. 12 CFR 583.18 - Registrant.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Registrant. 583.18 Section 583.18 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY DEFINITIONS FOR REGULATIONS AFFECTING SAVINGS AND LOAN HOLDING COMPANIES § 583.18 Registrant. The term registrant means a savings and loan...

  13. Determining the level of awareness of the physicians in using the variety of electronic information resources and the effecting factors.

    Science.gov (United States)

    Papi, Ahmad; Ghazavi, Roghayeh; Moradi, Salimeh

    2015-01-01

    Understanding of the medical society's from the types of information resources for quick and easy access to information is an imperative task in medical researches and management of the treatment. The present study was aimed to determine the level of awareness of the physicians in using various electronic information resources and the factors affecting it. This study was a descriptive survey. The data collection tool was a researcher-made questionnaire. The study population included all the physicians and specialty physicians of the teaching hospitals affiliated to Isfahan University of Medical Sciences and numbered 350. The sample size based on Morgan's formula was set at 180. The content validity of the tool was confirmed by the library and information professionals and the reliability was 95%. Descriptive statistics were used including the SPSS software version 19. On reviewing the need of the physicians to obtain the information on several occasions, the need for information in conducting the researches was reported by the maximum number of physicians (91.9%) and the usage of information resources, especially the electronic resources, formed 65.4% as the highest rate with regard to meeting the information needs of the physicians. Among the electronic information databases, the maximum awareness was related to Medline with 86.5%. Among the various electronic information resources, the highest awareness (43.3%) was related to the E-journals. The highest usage (36%) was also from the same source. The studied physicians considered the most effective deterrent in the use of electronic information resources as being too busy and lack of time. Despite the importance of electronic information resources for the physician's community, there was no comprehensive knowledge of these resources. This can lead to less usage of these resources. Therefore, careful planning is necessary in the hospital libraries in order to introduce the facilities and full capabilities of the

  14. Managing Selection for Electronic Resources: Kent State University Develops a New System to Automate Selection

    Science.gov (United States)

    Downey, Kay

    2012-01-01

    Kent State University has developed a centralized system that manages the communication and work related to the review and selection of commercially available electronic resources. It is an automated system that tracks the review process, provides selectors with price and trial information, and compiles reviewers' feedback about the resource. It…

  15. End-of-life resource recovery from emerging electronic products

    DEFF Research Database (Denmark)

    Parajuly, Keshav; Habib, Komal; Cimpan, Ciprian

    2016-01-01

    Integrating product design with appropriate end-of-life (EoL) processing is widely recognized to have huge potentials in improving resource recovery from electronic products. In this study, we investigate both the product characteristics and EoL processing of robotic vacuum cleaner (RVC), as a case...... of emerging electronic product, in order to understand the recovery fate of different materials and its linkage to product design. Ten different brands of RVC were dismantled and their material composition and design profiles were studied. Another 125 RVCs (349 kg) were used for an experimental trial...... at a conventional ‘shred-and-separate’ type preprocessing plant in Denmark. A detailed material flow analysis was performed throughout the recycling chain. The results show a mismatch between product design and EoL processing, and the lack of practical implementation of ‘Design for EoL’ thinking. In the best...

  16. Automatic registration using implicit shape representations: applications in intraoperative 3D rotational angiography to preoperative CTA registration

    International Nuclear Information System (INIS)

    Subramanian, Navneeth; Pichon, Eric; Solomon, Stephen B.

    2009-01-01

    A solution for automatic registration of 3D rotational angiography (XA) to CT/MR of the liver. Targeted for use in treatment planning of liver interventions. A shape-based approach to registration is proposed that does not require specification of landmarks nor is it prone to local minima like purely intensity-based registration methods. Through the use of vessel characteristics, accurate registration is possible even in the presence of deformations induced by catheters and respiratory motion. Registration was performed on eight pairs of multiphase CT angiography and 3D rotational digital angiography datasets. Quantitative validation of the registration accuracy using vessel landmarks was performed on these datasets. The validation study showed that the method has a registration error of 9.41±4.13 mm. In addition, the computation time is well below 60 s making it attractive for clinical application. A new method for fully automatic 3DXA to CT/MR image registration was developed and found to be efficient and accurate using clinically realistic datasets. (orig.)

  17. 75 FR 38521 - Registration Review; Biopesticide Dockets Opened for Review and Comment

    Science.gov (United States)

    2010-07-02

    ... in hard copy form. Publicly available docket materials are available either in the electronic docket at http://www.regulations.gov , or, if only available in hard copy, at the OPP Regulatory Public.... Section 3(g) of FIFRA provides, among other things, that the registrations of pesticides are to be...

  18. Use of electronic sales data to tailor nutrition education resources for an ethnically diverse population.

    Science.gov (United States)

    Eyles, H; Rodgers, A; Ni Mhurchu, C

    2010-02-01

    Nutrition education may be most effective when personally tailored. Individualised electronic supermarket sales data offer opportunities to tailor nutrition education using shopper's usual food purchases. The present study aimed to use individualised electronic supermarket sales data to tailor nutrition resources for an ethnically diverse population in a large supermarket intervention trial in New Zealand. Culturally appropriate nutrition education resources (i.e. messages and shopping lists) were developed with the target population (through two sets of focus groups) and ethnic researchers. A nutrient database of supermarket products was developed using retrospective sales data and linked to participant sales to allow tailoring by usual food purchases. Modified Heart Foundation Tick criteria were used to identify 'healthier' products in the database suitable for promotion in the resources. Rules were developed to create a monthly report listing the tailored and culturally targeted messages to be sent to each participant, and to produce automated, tailored shopping lists. Culturally targeted nutrition messages (n = 864) and shopping lists (n = 3 formats) were developed. The food and nutrient database (n = 3000 top-selling products) was created using 12 months of retrospective sales data, and comprised 60%'healthier' products. Three months of baseline sales data were used to determine usual food purchases. Tailored resources were successfully mailed to 123 Māori, 52 Pacific and 346 non-Māori non-Pacific participants over the 6-month trial intervention period. Electronic supermarket sales data can be used to tailor nutrition education resources for a large number of ethnically diverse supermarket shoppers.

  19. Availability, Level of Use and Constraints to Use of Electronic Resources by Law Lecturers in Public Universities in Nigeria

    Science.gov (United States)

    Amusa, Oyintola Isiaka; Atinmo, Morayo

    2016-01-01

    (Purpose) This study surveyed the level of availability, use and constraints to use of electronic resources among law lecturers in Nigeria. (Methodology) Five hundred and fifty-two law lecturers were surveyed and four hundred and forty-two responded. (Results) Data analysis revealed that the level of availability of electronic resources for the…

  20. Efficient nonrigid registration using ranked order statistics

    DEFF Research Database (Denmark)

    Tennakoon, Ruwan B.; Bab-Hadiashar, Alireza; de Bruijne, Marleen

    2013-01-01

    of research. In this paper we propose a fast and accurate non-rigid registration method for intra-modality volumetric images. Our approach exploits the information provided by an order statistics based segmentation method, to find the important regions for registration and use an appropriate sampling scheme......Non-rigid image registration techniques are widely used in medical imaging applications. Due to high computational complexities of these techniques, finding appropriate registration method to both reduce the computation burden and increase the registration accuracy has become an intense area...... to target those areas and reduce the registration computation time. A unique advantage of the proposed method is its ability to identify the point of diminishing returns and stop the registration process. Our experiments on registration of real lung CT images, with expert annotated landmarks, show...

  1. Beating-heart registration for organ-mounted robots.

    Science.gov (United States)

    Wood, Nathan A; Schwartzman, David; Passineau, Michael J; Moraca, Robert J; Zenati, Marco A; Riviere, Cameron N

    2018-03-06

    Organ-mounted robots address the problem of beating-heart surgery by adhering to the heart, passively providing a platform that approaches zero relative motion. Because of the quasi-periodic deformation of the heart due to heartbeat and respiration, registration must address not only spatial registration but also temporal registration. Motion data were collected in the porcine model in vivo (N = 6). Fourier series models of heart motion were developed. By comparing registrations generated using an iterative closest-point approach at different phases of respiration, the phase corresponding to minimum registration distance is identified. The spatiotemporal registration technique presented here reduces registration error by an average of 4.2 mm over the 6 trials, in comparison with a more simplistic static registration that merely averages out the physiological motion. An empirical metric for spatiotemporal registration of organ-mounted robots is defined and demonstrated using data from animal models in vivo. Copyright © 2018 John Wiley & Sons, Ltd.

  2. A systematic review of portable electronic technology for health education in resource-limited settings.

    Science.gov (United States)

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  3. 75 FR 60117 - Registration Review; Biopesticides Dockets Opened for Review and Comment

    Science.gov (United States)

    2010-09-29

    ... publicly available only in hard copy form. Publicly available docket materials are available either in the electronic docket at http://www.regulations.gov , or, if only available in hard copy, at the OPP Regulatory.... Section 3(g) of FIFRA provides, among other things, that the registrations of pesticides are to be...

  4. SAGES: a suite of freely-available software tools for electronic disease surveillance in resource-limited settings.

    Directory of Open Access Journals (Sweden)

    Sheri L Lewis

    Full Text Available Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.

  5. Use and Cost of Electronic Resources in Central Library of Ferdowsi University Based on E-metrics

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Davarpanah

    2012-07-01

    Full Text Available The purpose of this study was to investigate the usage of electronic journals in Ferdowsi University, Iran based on e-metrics. The paper also aimed to emphasize the analysis of cost-benefit and the correlation between the journal impact factors and the usage data. In this study experiences of Ferdowsi University library on licensing and usage of electronic resources was evaluated by providing a cost-benefit analysis based on the cost and usage statistics of electronic resources. Vendor-provided data were also compared with local usage data. The usage data were collected by tracking web-based access locally, and by collecting vender-provided usage data. The data sources were one-year of vendor-supplied e-resource usage data such as Ebsco, Elsevier, Proquest, Emerald, Oxford and Springer and local usage data collected from the Ferdowsi university web server. The study found that actual usage values differ for vendor-provided data and local usage data. Elsevier has got the highest usage degree in searches, sessions and downloads. Statistics also showed that a small number of journals satisfy significant amount of use while the majority of journals were used less frequent and some were never used at all. The users preferred the PDF rather than HTML format. The data in subject profile suggested that the provided e-resources were best suited to certain subjects. There was no correlation between IF and electronic journal use. Monitoring the usage of e-resources gained increasing importance for acquisition policy and budget decisions. The article provided information about local metrics for the six surveyed vendors/publishers, e.g. usage trends, requests per package, cost per use as related to the scientific specialty of the university.

  6. Clinical trial registration in oral health journals.

    Science.gov (United States)

    Smaïl-Faugeron, V; Fron-Chabouis, H; Durieux, P

    2015-03-01

    Prospective registration of randomized controlled trials (RCTs) represents the best solution to reporting bias. The extent to which oral health journals have endorsed and complied with RCT registration is unknown. We identified journals publishing RCTs in dentistry, oral surgery, and medicine in the Journal Citation Reports. We classified journals into 3 groups: journals requiring or recommending trial registration, journals referring indirectly to registration, and journals providing no reference to registration. For the 5 journals with the highest 2012 impact factors in each group, we assessed whether RCTs with results published in 2013 had been registered. Of 78 journals examined, 32 (41%) required or recommended trial registration, 19 (24%) referred indirectly to registration, and 27 (35%) provided no reference to registration. We identified 317 RCTs with results published in the 15 selected journals in 2013. Overall, 73 (23%) were registered in a trial registry. Among those, 91% were registered retrospectively and 32% did not report trial registration in the published article. The proportion of trials registered was not significantly associated with editorial policies: 29% with results in journals that required or recommended registration, 15% in those that referred indirectly to registration, and 21% in those providing no reference to registration (P = 0.05). Less than one-quarter of RCTs with results published in a sample of oral health journals were registered with a public registry. Improvements are needed with respect to how journals inform and require their authors to register their trials. © International & American Associations for Dental Research.

  7. 40 CFR 164.21 - Contents of a denial of registration, notice of intent to cancel a registration, or notice of...

    Science.gov (United States)

    2010-07-01

    ..., notice of intent to cancel a registration, or notice of intent to change a classification. 164.21 Section... denial of registration, notice of intent to cancel a registration, or notice of intent to change a classification. (a) Contents. The denial of registration or a notice of intent to cancel a registration or to...

  8. Building and Managing Electronic Resources in Digital Era in India with Special Reference to IUCAA and NIV, Pune: A Comparative Case Study

    Science.gov (United States)

    Sahu, H. K.; Singh, S. N.

    2015-04-01

    This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.

  9. Image registration with auto-mapped control volumes

    International Nuclear Information System (INIS)

    Schreibmann, Eduard; Xing Lei

    2006-01-01

    Many image registration algorithms rely on the use of homologous control points on the two input image sets to be registered. In reality, the interactive identification of the control points on both images is tedious, difficult, and often a source of error. We propose a two-step algorithm to automatically identify homologous regions that are used as a priori information during the image registration procedure. First, a number of small control volumes having distinct anatomical features are identified on the model image in a somewhat arbitrary fashion. Instead of attempting to find their correspondences in the reference image through user interaction, in the proposed method, each of the control regions is mapped to the corresponding part of the reference image by using an automated image registration algorithm. A normalized cross-correlation (NCC) function or mutual information was used as the auto-mapping metric and a limited memory Broyden-Fletcher-Goldfarb-Shanno algorithm (L-BFGS) was employed to optimize the function to find the optimal mapping. For rigid registration, the transformation parameters of the system are obtained by averaging that derived from the individual control volumes. In our deformable calculation, the mapped control volumes are treated as the nodes or control points with known positions on the two images. If the number of control volumes is not enough to cover the whole image to be registered, additional nodes are placed on the model image and then located on the reference image in a manner similar to the conventional BSpline deformable calculation. For deformable registration, the established correspondence by the auto-mapped control volumes provides valuable guidance for the registration calculation and greatly reduces the dimensionality of the problem. The performance of the two-step registrations was applied to three rigid registration cases (two PET-CT registrations and a brain MRI-CT registration) and one deformable registration of

  10. 76 FR 10291 - Amendment to the International Traffic in Arms Regulations: Electronic Payment of Registration...

    Science.gov (United States)

    2011-02-24

    ..., Bureau of Political Military Affairs, U.S. Department of State, Washington, DC 20522-0112. Persons with... DS-2032, Statement of Registration, submission) certifying criminal history, eligibility, and foreign... Office: Bureau of Political-Military Affairs, Directorate of Defense Trade Controls, PM/DDTC. Form Number...

  11. 75 FR 60119 - Registration Review; Antimicrobial Pesticide Dockets Opened for Review and Comment

    Science.gov (United States)

    2010-09-29

    ... and will be publicly available only in hard copy form. Publicly available docket materials are available either in the electronic docket at http://www.regulations.gov , or, if only available in hard copy... 155, subpart C. Section 3(g) of FIFRA provides, among other things, that the registrations of...

  12. 46 CFR 402.220 - Registration of pilots.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Registration of pilots. 402.220 Section 402.220 Shipping... ORDERS Registration of Pilots § 402.220 Registration of pilots. (a) Each applicant pilot must complete the number of round trips specified in this section prior to registration as a U.S. registered pilot...

  13. A novel 3D volumetric voxel registration technique for volume-view-guided image registration of multiple imaging modalities

    International Nuclear Information System (INIS)

    Li Guang; Xie Huchen; Ning, Holly; Capala, Jacek; Arora, Barbara C.; Coleman, C. Norman; Camphausen, Kevin; Miller, Robert W.

    2005-01-01

    Purpose: To provide more clinically useful image registration with improved accuracy and reduced time, a novel technique of three-dimensional (3D) volumetric voxel registration of multimodality images is developed. Methods and Materials: This technique can register up to four concurrent images from multimodalities with volume view guidance. Various visualization effects can be applied, facilitating global and internal voxel registration. Fourteen computed tomography/magnetic resonance (CT/MR) image sets and two computed tomography/positron emission tomography (CT/PET) image sets are used. For comparison, an automatic registration technique using maximization of mutual information (MMI) and a three-orthogonal-planar (3P) registration technique are used. Results: Visually sensitive registration criteria for CT/MR and CT/PET have been established, including the homogeneity of color distribution. Based on the registration results of 14 CT/MR images, the 3D voxel technique is in excellent agreement with the automatic MMI technique and is indicatory of a global positioning error (defined as the means and standard deviations of the error distribution) using the 3P pixel technique: 1.8 deg ± 1.2 deg in rotation and 2.0 ± 1.3 (voxel unit) in translation. To the best of our knowledge, this is the first time that such positioning error has been addressed. Conclusion: This novel 3D voxel technique establishes volume-view-guided image registration of up to four modalities. It improves registration accuracy with reduced time, compared with the 3P pixel technique. This article suggests that any interactive and automatic registration should be safeguarded using the 3D voxel technique

  14. Spherical Demons: Fast Surface Registration

    Science.gov (United States)

    Yeo, B.T. Thomas; Sabuncu, Mert; Vercauteren, Tom; Ayache, Nicholas; Fischl, Bruce; Golland, Polina

    2009-01-01

    We present the fast Spherical Demons algorithm for registering two spherical images. By exploiting spherical vector spline interpolation theory, we show that a large class of regularizers for the modified demons objective function can be efficiently implemented on the sphere using convolution. Based on the one parameter subgroups of diffeomorphisms, the resulting registration is diffeomorphic and fast – registration of two cortical mesh models with more than 100k nodes takes less than 5 minutes, comparable to the fastest surface registration algorithms. Moreover, the accuracy of our method compares favorably to the popular FreeSurfer registration algorithm. We validate the technique in two different settings: (1) parcellation in a set of in-vivo cortical surfaces and (2) Brodmann area localization in ex-vivo cortical surfaces. PMID:18979813

  15. 32 CFR 634.19 - Registration policy.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Registration policy. 634.19 Section 634.19 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Motor Vehicle Registration § 634.19 Registration policy. (a) Motor vehicles will be...

  16. 5 CFR 1201.14 - Electronic filing procedures.

    Science.gov (United States)

    2010-01-01

    ... form. (b) Matters subject to electronic filing. Subject to the registration requirement of paragraph (e) of this section, parties and representatives may use electronic filing (e-filing) to do any of the...). (d) Internet is sole venue for electronic filing. Following the instructions at e-Appeal Online, the...

  17. The First 500 Registrations to the Research Registry®: Advancing Registration of Under-registered Study Types

    Directory of Open Access Journals (Sweden)

    Riaz Agha

    2016-09-01

    Full Text Available The Declaration of Helsinki 2013 encourages the registration of all research studies involving human participants. However, emphasis has been placed on prospective clinical trials, and it is estimated that only 10% of observational studies are registered. In response, Research Registry® was launched in February 2015; a retrospectively curated registry that is free and easy to use. Research Registry® enables prospective or retrospective registration of studies, including those study types that cannot be registered on existing registries. In this study, we describe the first 500 registrations on Research Registry®.Since the launch of Research Registry® in February 2015, data of registrations have been collected, including type of studies registered, country of origin and data curation activity. Inappropriate registrations, such as duplicates, were identified by the data curation process. These were removed from the database or modified as required. A quality score was assigned for each registration, based on Bradford-Hill’s criteria on what research studies should convey. Changes in quality scores over time were assessed. 500 studies were registered on Research Registry® from February 2015 to October 2015, with a total of 1.7 million patients enrolled. The most common study types were retrospective cohort studies (37.2%, case series (14.8% and first-in-man case reports (10.4%. Registrations were received from 57 different countries; the most submissions were received from Turkey, followed by China and the United Kingdom. Retrospective data curation identified 80 studies that were initially registered as the incorrect study type, and were subsequently correct. The Kruskal-Wallis test identified a significant improvement in quality scores for registrations from February 2015 to October 2015 (p < 0.0001.Since its conception in February 2015, Research Registry® has established itself as a new registry that is free, easy to use and enables the

  18. The First 500 Registrations to the Research Registry®: Advancing Registration of Under-Registered Study Types.

    Science.gov (United States)

    Agha, Riaz; Fowler, Alexander J; Limb, Christopher; Al Omran, Yasser; Sagoo, Harkiran; Koshy, Kiron; Jafree, Daniyal J; Anwar, Mohammed Omer; McCullogh, Peter; Orgill, Dennis Paul

    2016-01-01

    The Declaration of Helsinki 2013 encourages the registration of all research studies involving human participants. However, emphasis has been placed on prospective clinical trials, and it is estimated that only 10% of observational studies are registered. In response, Research Registry ® was launched in February 2015; a retrospectively curated registry that is free and easy to use. Research Registry ® enables prospective or retrospective registration of studies, including those study types that cannot be registered on existing registries. In this study, we describe the first 500 registrations on Research Registry ® . Since the launch of Research Registry ® in February 2015, data of registrations have been collected, including type of studies registered, country of origin, and data curation activity. Inappropriate registrations, such as duplicates, were identified by the data curation process. These were removed from the database or modified as required. A quality score was assigned for each registration, based on Sir Austin Bradford Hill's criteria on what research studies should convey. Changes in quality scores over time were assessed. A total of 500 studies were registered on Research Registry ® from February 2015 to October 2015, with a total of 1.7 million patients enrolled. The most common study types were retrospective cohort studies (37.2%), case series (14.8%), and first-in-man case reports (10.4%). Registrations were received from 57 different countries; the most submissions were received from Turkey, followed by China and the United Kingdom. Retrospective data curation identified 80 studies that were initially registered as the incorrect study type, and were subsequently correct. The Kruskal-Wallis test identified a significant improvement in quality scores for registrations from February 2015 to October 2015 ( p  < 0.0001). Since its conception in February 2015, Research Registry ® has established itself as a new registry that is free, easy to

  19. [Use of internet and electronic resources among Spanish intensivist physicians. First national survey].

    Science.gov (United States)

    Gómez-Tello, V; Latour-Pérez, J; Añón Elizalde, J M; Palencia-Herrejón, E; Díaz-Alersi, R; De Lucas-García, N

    2006-01-01

    Estimate knowledge and use habits of different electronic resources in a sample of Spanish intensivists: Internet, E-mail, distribution lists, and use of portable electronic devices. Self-applied questionnaire. A 50-question questionnaire was distributed among Spanish intensivists through the hospital marketing delegates of a pharmaceutical company and of electronic forums. A total of 682 questionnaires were analyzed (participation: 74%). Ninety six percent of those surveyed used Internet individually: 67% admitted training gap. Internet was the second source of clinical consultations most used (61%), slightly behind consultation to colleagues (65%). The pages consulted most were bibliographic databases (65%) and electronic professional journals (63%), with limited use of Evidence Based Medicine pages (19%). Ninety percent of those surveyed used e-mail regularly in the practice of their profession, although 25% admitted that were not aware of its possibilities. The use of E-mail decreased significantly with increase in age. A total of 62% of the intensivists used distribution lists. Of the rest, 42% were not aware of its existence and 32% admitted they had insufficient training to handle them. Twenty percent of those surveyed had portable electronic devices and 64% considered it useful, basically due to its rapid consultation at bedside. Female gender was a negative predictive factor of its use (OR 0.35; 95% CI 0.2-0.63; p=0.0002). A large majority of the Spanish intensivists use Internet and E-mail. E-mail lists and use of portable devices are still underused resources. There are important gaps in training and infrequent use of essential pages. There are specific groups that require directed educational policies.

  20. Model of e-learning with electronic educational resources of new generation

    OpenAIRE

    A. V. Loban; D. A. Lovtsov

    2017-01-01

    Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with elec...

  1. Victoria's review of registration for health practitioners.

    Science.gov (United States)

    Scotts, H; Carter, M

    1988-01-01

    This article discusses some of the issues raised in the Interim Report of the current Review of Registration of Health Practitioners being conducted for the Victorian Health Department. The Report attempts to develop the framework in which the registration Boards will operate as part of a cohesive registration system. It proposed a mechanism and criteria for the registration of new groups as well as principles which can be applied to the ongoing review of each existing Board. The Review takes the perspective that registration of health practitioners carries with it both advantages and disadvantages for the general community. Under the proposed new system the controls exercised over health care providers by Registration Boards would be evaluated on the basis of to what extent the benefits to the public outweighed the potential costs. It is in this context that the Report addresses issues such as consumer complaints handling, registration of individual practitioners and controls over professional advertising and other business practices.

  2. Impact of Knowledge Resources Linked to an Electronic Health Record on Frequency of Unnecessary Tests and Treatments

    Science.gov (United States)

    Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John

    2012-01-01

    Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…

  3. Electronic Document Management: A Human Resource Management Case Study

    Directory of Open Access Journals (Sweden)

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  4. Locally orderless registration code

    DEFF Research Database (Denmark)

    2012-01-01

    This is code for the TPAMI paper "Locally Orderless Registration". The code requires intel threadding building blocks installed and is provided for 64 bit on mac, linux and windows.......This is code for the TPAMI paper "Locally Orderless Registration". The code requires intel threadding building blocks installed and is provided for 64 bit on mac, linux and windows....

  5. Deformable Registration for Longitudinal Breast MRI Screening.

    Science.gov (United States)

    Mehrabian, Hatef; Richmond, Lara; Lu, Yingli; Martel, Anne L

    2018-04-13

    MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T 1 -weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that

  6. 78 FR 33419 - Announcement of Requirements and Registration for “Blue Button Co-Design Challenge”

    Science.gov (United States)

    2013-06-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Announcement of Requirements and Registration for ``Blue Button Co-Design Challenge'' AGENCY: Office of the National Coordinator for Health Information Technology... Electronic Health Record into another product or holding place of their choice. This is an enormous...

  7. "MedTRIS" (Medical Triage and Registration Informatics System): A Web-based Client Server System for the Registration of Patients Being Treated in First Aid Posts at Public Events and Mass Gatherings.

    Science.gov (United States)

    Gogaert, Stefan; Vande Veegaete, Axel; Scholliers, Annelies; Vandekerckhove, Philippe

    2016-10-01

    First aid (FA) services are provisioned on-site as a preventive measure at most public events. In Flanders, Belgium, the Belgian Red Cross-Flanders (BRCF) is the major provider of these FA services with volunteers being deployed at approximately 10,000 public events annually. The BRCF has systematically registered information on the patients being treated in FA posts at major events and mass gatherings during the last 10 years. This information has been collected in a web-based client server system called "MedTRIS" (Medical Triage and Registration Informatics System). MedTRIS contains data on more than 200,000 patients at 335 mass events. This report describes the MedTRIS architecture, the data collected, and how the system operates in the field. This database consolidates different types of information with regards to FA interventions in a standardized way for a variety of public events. MedTRIS allows close monitoring in "real time" of the situation at mass gatherings and immediate intervention, when necessary; allows more accurate prediction of resources needed; allows to validate conceptual and predictive models for medical resources at (mass) public events; and can contribute to the definition of a standardized minimum data set (MDS) for mass-gathering health research and evaluation. Gogaert S , Vande veegaete A , Scholliers A , Vandekerckhove P . "MedTRIS" (Medical Triage and Registration Informatics System): a web-based client server system for the registration of patients being treated in first aid posts at public events and mass gatherings. Prehosp Disaster Med. 2016;31(5):557-562.

  8. A sequential decision framework for increasing college students' support for organ donation and organ donor registration.

    Science.gov (United States)

    Peltier, James W; D'Alessandro, Anthony M; Dahl, Andrew J; Feeley, Thomas Hugh

    2012-09-01

    Despite the fact that college students support social causes, this age group has underparticipated in organ donor registration. Little research attention has been given to understanding deeper, higher-order relationships between the antecedent attitudes toward and perceptions of organ donation and registration behavior. To test a process model useful for understanding the sequential ordering of information necessary for moving college students along a hierarchical decision-making continuum from awareness to support to organ donor registration. The University of Wisconsin organ procurement organization collaborated with the Collegiate American Marketing Association on a 2-year grant funded by the US Health Resources and Services Administration. A total of 981 association members responded to an online questionnaire. The 5 antecedent measures were awareness of organ donation, need acknowledgment, benefits of organ donation, social support, and concerns about organ donation. The 2 consequence variables were support for organ donation and organ donation registration. Structural equation modeling indicated that 5 of 10 direct antecedent pathways led significantly into organ donation support and registration. The impact of the nonsignificant variables was captured via indirect effects through other decision variables. Model fit statistics were good: the goodness of fit index was .998, the adjusted goodness of fit index was .992, and the root mean square error of approximation was .001. This sequential decision-making model provides insight into the need to enhance the acceptance of organ donation and organ donor registration through a series of communications to move people from awareness to behavior.

  9. Medical Image Registration and Surgery Simulation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten

    1996-01-01

    This thesis explores the application of physical models in medical image registration and surgery simulation. The continuum models of elasticity and viscous fluids are described in detail, and this knowledge is used as a basis for most of the methods described here. Real-time deformable models......, and the use of selective matrix vector multiplication. Fluid medical image registration A new and faster algorithm for non-rigid registration using viscous fluid models is presented. This algorithm replaces the core part of the original algorithm with multi-resolution convolution using a new filter, which...... growth is also presented. Using medical knowledge about the growth processes of the mandibular bone, a registration algorithm for time sequence images of the mandible is developed. Since this registration algorithm models the actual development of the mandible, it is possible to simulate the development...

  10. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  11. Closing the loop of the medication use process using electronic medication administration registration.

    Science.gov (United States)

    Lenderink, Bertil W; Egberts, Toine C G

    2004-08-01

    Recent reports and studies of errors in the medication process have raised the awareness of the threat to public health. An essential step in this multi-stage process is the actual administration of a medicine to the patient. The closed loop system is thought to be a way of preventing medication errors. Current information technology can facilitate this process. This article describes the way barcode technology is being used to facilitate medication administration registration on several wards in our hospital and nursing home.

  12. Medical image registration for analysis

    International Nuclear Information System (INIS)

    Petrovic, V.

    2006-01-01

    Full text: Image registration techniques represent a rich family of image processing and analysis tools that aim to provide spatial correspondences across sets of medical images of similar and disparate anatomies and modalities. Image registration is a fundamental and usually the first step in medical image analysis and this paper presents a number of advanced techniques as well as demonstrates some of the advanced medical image analysis techniques they make possible. A number of both rigid and non-rigid medical image alignment algorithms of equivalent and merely consistent anatomical structures respectively are presented. The algorithms are compared in terms of their practical aims, inputs, computational complexity and level of operator (e.g. diagnostician) interaction. In particular, the focus of the methods discussion is placed on the applications and practical benefits of medical image registration. Results of medical image registration on a number of different imaging modalities and anatomies are presented demonstrating the accuracy and robustness of their application. Medical image registration is quickly becoming ubiquitous in medical imaging departments with the results of such algorithms increasingly used in complex medical image analysis and diagnostics. This paper aims to demonstrate at least part of the reason why

  13. Surface-based prostate registration with biomechanical regularization

    Science.gov (United States)

    van de Ven, Wendy J. M.; Hu, Yipeng; Barentsz, Jelle O.; Karssemeijer, Nico; Barratt, Dean; Huisman, Henkjan J.

    2013-03-01

    Adding MR-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound by using MRUS registration. A common approach is to use surface-based registration. We hypothesize that biomechanical modeling will better control deformation inside the prostate than a regular surface-based registration method. We developed a novel method by extending a surface-based registration with finite element (FE) simulation to better predict internal deformation of the prostate. For each of six patients, a tetrahedral mesh was constructed from the manual prostate segmentation. Next, the internal prostate deformation was simulated using the derived radial surface displacement as boundary condition. The deformation field within the gland was calculated using the predicted FE node displacements and thin-plate spline interpolation. We tested our method on MR guided MR biopsy imaging data, as landmarks can easily be identified on MR images. For evaluation of the registration accuracy we used 45 anatomical landmarks located in all regions of the prostate. Our results show that the median target registration error of a surface-based registration with biomechanical regularization is 1.88 mm, which is significantly different from 2.61 mm without biomechanical regularization. We can conclude that biomechanical FE modeling has the potential to improve the accuracy of multimodal prostate registration when comparing it to regular surface-based registration.

  14. 40 CFR 68.160 - Registration.

    Science.gov (United States)

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Risk Management Plan § 68.160 Registration. (a) The owner or operator shall... substances handled in covered processes. (b) The registration shall include the following data: (1...

  15. Optical registration of spaceborne low light remote sensing camera

    Science.gov (United States)

    Li, Chong-yang; Hao, Yan-hui; Xu, Peng-mei; Wang, Dong-jie; Ma, Li-na; Zhao, Ying-long

    2018-02-01

    For the high precision requirement of spaceborne low light remote sensing camera optical registration, optical registration of dual channel for CCD and EMCCD is achieved by the high magnification optical registration system. System integration optical registration and accuracy of optical registration scheme for spaceborne low light remote sensing camera with short focal depth and wide field of view is proposed in this paper. It also includes analysis of parallel misalignment of CCD and accuracy of optical registration. Actual registration results show that imaging clearly, MTF and accuracy of optical registration meet requirements, it provide important guarantee to get high quality image data in orbit.

  16. Skull registration for prone patient position using tracked ultrasound

    Science.gov (United States)

    Underwood, Grace; Ungi, Tamas; Baum, Zachary; Lasso, Andras; Kronreif, Gernot; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Tracked navigation has become prevalent in neurosurgery. Problems with registration of a patient and a preoperative image arise when the patient is in a prone position. Surfaces accessible to optical tracking on the back of the head are unreliable for registration. We investigated the accuracy of surface-based registration using points accessible through tracked ultrasound. Using ultrasound allows access to bone surfaces that are not available through optical tracking. Tracked ultrasound could eliminate the need to work (i) under the table for registration and (ii) adjust the tracker between surgery and registration. In addition, tracked ultrasound could provide a non-invasive method in comparison to an alternative method of registration involving screw implantation. METHODS: A phantom study was performed to test the feasibility of tracked ultrasound for registration. An initial registration was performed to partially align the pre-operative computer tomography data and skull phantom. The initial registration was performed by an anatomical landmark registration. Surface points accessible by tracked ultrasound were collected and used to perform an Iterative Closest Point Algorithm. RESULTS: When the surface registration was compared to a ground truth landmark registration, the average TRE was found to be 1.6+/-0.1mm and the average distance of points off the skull surface was 0.6+/-0.1mm. CONCLUSION: The use of tracked ultrasound is feasible for registration of patients in prone position and eliminates the need to perform registration under the table. The translational component of error found was minimal. Therefore, the amount of TRE in registration is due to a rotational component of error.

  17. Considering Point-of-Care Electronic Medical Resources in Lieu of Traditional Textbooks for Medical Education.

    Science.gov (United States)

    Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L

    2015-09-01

    Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.

  18. Solid Mesh Registration for Radiotherapy Treatment Planning

    DEFF Research Database (Denmark)

    Noe, Karsten Østergaard; Sørensen, Thomas Sangild

    2010-01-01

    We present an algorithm for solid organ registration of pre-segmented data represented as tetrahedral meshes. Registration of the organ surface is driven by force terms based on a distance field representation of the source and reference shapes. Registration of internal morphology is achieved usi...

  19. [Ideas about registration for sodium hyaluronate facial derma fillers].

    Science.gov (United States)

    Zhao, Peng; Shi, Xinli; Liu, Wenbo; Lu, Hong

    2012-09-01

    To review the registration and technical data for sodium hyaluronate facial derma fillers. Recent literature concerning registration for sodium hyaluronate facial derma fillers was reviewed and analyzed. The aspects on registration for sodium hyaluronate facial derma fillers include nominating the product, dividing registration unit, filling in a registration application form, preparing the technical data, developing the standard, and developing a registration specification. The main difficulty in registration is how to prepare the research data of that product, so the manufacturers need to enhance their basic research ability and work out a scientific technique routing which could ensure the safety and effectiveness of the product, also help to set up the supportive documents to medical device registration.

  20. Pro Forma Registration of Companies

    DEFF Research Database (Denmark)

    Werlauff, Erik

    2010-01-01

    The article analyses the view taken by Community law on companies' pro forma registration in another EU or EEA country. Community law recognises pro forma registration under company law, i.e. a brass plate is sufficient, whereas it does not recognise pro forma registration under tax law, i.......e. a brass plate is not sufficient. The article provides reasons for the differential treatment of the two contexts and clarifies the difference on the basis of the Hubbard criterion, in which it was ruled that the effectiveness of Community law cannot vary according to the various branches of national law....

  1. Fiducial-based registration with a touchable region model.

    Science.gov (United States)

    Kim, Sungmin; Kazanzides, Peter

    2017-02-01

    Image-guided surgery requires registration between an image coordinate system and an intraoperative coordinate system that is typically referenced to a tracking device. In fiducial-based registration methods, this is achieved by localizing points (fiducials) in each coordinate system. Often, both localizations are performed manually, first by picking a fiducial point in the image and then by using a hand-held tracked pointer to physically touch the corresponding fiducial on the patient. These manual procedures introduce localization error that is user-dependent and can significantly decrease registration accuracy. Thus, there is a need for a registration method that is tolerant of imprecise fiducial localization in the preoperative and intraoperative phases. We propose the iterative closest touchable point (ICTP) registration framework, which uses model-based localization and a touchable region model. This method consists of three stages: (1) fiducial marker localization in image space, using a fiducial marker model, (2) initial registration with paired-point registration, and (3) fine registration based on the iterative closest point method. We perform phantom experiments with a fiducial marker design that is commonly used in neurosurgery. The results demonstrate that ICTP can provide accuracy improvements compared to the standard paired-point registration method that is widely used for surgical navigation and surgical robot systems, especially in cases where the surgeon introduces large localization errors. The results demonstrate that the proposed method can reduce the effect of the surgeon's localization performance on the accuracy of registration, thereby producing more consistent and less user-dependent registration outcomes.

  2. Resource conservation approached with an appropriate collection and upgrade-remanufacturing for used electronic products.

    Science.gov (United States)

    Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui

    2018-03-01

    This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.

  3. 40 CFR 152.115 - Conditions of registration.

    Science.gov (United States)

    2010-07-01

    ... specify any provisions for sale and distribution of existing stocks of the pesticide product. (3) The... PESTICIDE REGISTRATION AND CLASSIFICATION PROCEDURES Agency Review of Applications § 152.115 Conditions of registration. (a) Substantially similar products and new uses. Each registration issued under § 152.113 shall...

  4. Effects of the Use of Electronic Human Resource Management (EHRM Within Human Resource Management (HRM Functions at Universities

    Directory of Open Access Journals (Sweden)

    Chux Gervase Iwu

    2016-09-01

    Full Text Available This study set out to examine the effect of e-hrm systems in assisting human resource practitioners to execute their duties and responsibilities. In comparison to developed economies of the world, information technology adoption in sub-Saharan Africa has not been without certain glitches. Some of the factors that are responsible for these include poor need identification, sustainable funding, and insufficient skills. Besides these factors, there is also the issue of change management and users sticking to what they already know. Although, the above factors seem negative, there is strong evidence that information systems such as electronic human resource management present benefits to an organization. To achieve this, a dual research approach was utilized. Literature assisted immensely in both the development of the conceptual framework upon which the study hinged as well as in the development of the questionnaire items. The study also made use of an interview checklist to guide the participants. The findings reveal a mix of responses that indicate that while there are gains in adopting e-hrm systems, it is wiser to consider supporting resources as well as articulate the needs of the university better before any investment is made.

  5. Electronic human resource management: Enhancing or entrancing?

    Directory of Open Access Journals (Sweden)

    Paul Poisat

    2017-07-01

    Full Text Available Orientation: This article provides an investigation into the current level of development of the body of knowledge related to electronic human resource management (e-HRM by means of a qualitative content analysis. Several aspects of e-HRM, namely definitions of e-HRM, the theoretical perspectives around e-HRM, the role of e-HRM, the various types of e-HRM and the requirements for successful e-HRM, are examined. Research purpose: The purpose of the article was to determine the status of e-HRM and examine the studies that report on the link between e-HRM and organisational productivity. Motivation for the study: e-HRM has the capacity to improve organisational efficiency and leverage the role of human resources (HR as a strategic business partner. Main findings: The notion that the implementation of e-HRM will lead to improved organisational productivity is commonly assumed; however, empirical evidence in this regard was found to be limited. Practical/managerial implications: From the results of this investigation it is evident that more research is required to gain a greater understanding of the influence of e-HRM on organisational productivity, as well as to develop measures for assessing this influence. Contribution: This article proposes additional areas to research and measure when investigating the effectiveness of e-HRM. It provides a different lens from which to view e-HRM assessment whilst keeping it within recognised HR measurement parameters (the HR value chain. In addition, it not only provides areas for measuring e-HRM’s influence but also provides important clues as to how the measurements may be approached.

  6. 32 CFR 635.27 - Vehicle Registration System.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Vehicle Registration System. 635.27 Section 635.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS LAW ENFORCEMENT REPORTING Offense Reporting § 635.27 Vehicle Registration System. The Vehicle Registration System (VR...

  7. 37 CFR 1.293 - Statutory invention registration.

    Science.gov (United States)

    2010-07-01

    ... the date of publication of the statutory invention registration; (2) The required fee for filing a request for publication of a statutory invention registration as provided for in § 1.17 (n) or (o); (3) A... application. (b) Any request for publication of a statutory invention registration must include the following...

  8. Registration of the cancer

    International Nuclear Information System (INIS)

    Morales, F.; Campos, X.

    2002-01-01

    A database for the registration of the cancer was designed in ambient access, of the Microsoft Office, to take the registrations at national level. With this database the statistics will be obtained about the incidence of the cancer in the population, evaluation of the sanitary services of prevention, diagnose and treatment of the illness, etc. The used codes are according to the listings of code of the Ministry of Health (MINSA) and OPS

  9. Promoting learning transfer in post registration education: a collaborative approach.

    Science.gov (United States)

    Finn, Frances L; Fensom, Sue A; Chesser-Smyth, Patricia

    2010-01-01

    Pre-registration nurse education in Ireland became a four year undergraduate honors degree programme in 2002 (Government of Ireland, 2000. The Nursing Education Forum Report. Dublin, Dublin Stationary Office.). Consequently, the Irish Government invested significant resources in post registration nursing education in order to align certificate and diploma trained nurses with the qualification levels of new graduates. However, a general concern amongst academic and clinical staff in the South East of Ireland was that there was limited impact of this initiative on practice. These concerns were addressed through a collaborative approach to the development and implementation of a new part-time post registration degree that incorporated an enquiry and practice based learning philosophy. The principles of learning transfer (Ford, K., 1994. Defining transfer of learning the meaning is in the answers. Adult Learning 5 (4), p. 2214.) underpinned the curriculum development and implementation process with the goal of reducing the theory practice gap. This paper reports on all four stages of the curriculum development process: exploration, design, implementation and evaluation (Quinn, F.M., 2002. Principles and Practices of Nurse Education, fourth ed. Nelson Thornes, Cheltenham), and the subsequent impact of learning transfer on practice development. Eclectic approaches of quantitative and qualitative data collection techniques were utilised in the evaluation. The evaluation of this project to date supports our view that this practice based enquiry curriculum promotes the transfer of learning in the application of knowledge to practice, impacting both student and service development.

  10. 46 CFR 401.220 - Registration of pilots.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Registration of pilots. 401.220 Section 401.220 Shipping... Registration of Pilots § 401.220 Registration of pilots. (a) The Director shall determine the number of pilots... waters of the Great Lakes and to provide for equitable participation of United States Registered Pilots...

  11. Identifying and evaluating electronic learning resources for use in adult-gerontology nurse practitioner education.

    Science.gov (United States)

    Thompson, Hilaire J; Belza, Basia; Baker, Margaret; Christianson, Phyllis; Doorenbos, Ardith; Nguyen, Huong

    2014-01-01

    Enhancing existing curricula to meet newly published adult-gerontology advanced practice registered nurse (APRN) competencies in an efficient manner presents a challenge to nurse educators. Incorporating shared, published electronic learning resources (ELRs) in existing or new courses may be appropriate in order to assist students in achieving competencies. The purposes of this project were to (a) identify relevant available ELR for use in enhancing geriatric APRN education and (b) to evaluate the educational utility of identified ELRs based on established criteria. A multilevel search strategy was used. Two independent team members reviewed identified ELR against established criteria to ensure utility. Only resources meeting all criteria were retained. Resources were found for each of the competency areas and included formats such as podcasts, Web casts, case studies, and teaching videos. In many cases, resources were identified using supplemental strategies and not through traditional search or search of existing geriatric repositories. Resources identified have been useful to advanced practice educators in improving lecture and seminar content in a particular topic area and providing students and preceptors with additional self-learning resources. Addressing sustainability within geriatric APRN education is critical for sharing of best practices among educators and for sustainability of teaching and related resources. © 2014.

  12. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. Customizable Electronic Laboratory Online (CELO): A Web-based Data Management System Builder for Biomedical Research Laboratories

    Science.gov (United States)

    Fong, Christine; Brinkley, James F.

    2006-01-01

    A common challenge among today’s biomedical research labs is managing growing amounts of research data. In order to reduce the time and resource costs of building data management tools, we designed the Customizable Electronic Laboratory Online (CELO) system. CELO automatically creates a generic database and web interface for laboratories that submit a simple web registration form. Laboratories can then use a collection of predefined XML templates to assist with the design of a database schema. Users can immediately utilize the web-based system to query data, manage multimedia files, and securely share data remotely over the internet. PMID:17238541

  14. [New electronic data carriers in Bosnia-Herzegovina].

    Science.gov (United States)

    Masić, I; Pandza, H; Knezević, Z; Toromanović, S

    1999-01-01

    Bosnia and Herzegovina has been developing new Health Care System based on Electronic Registration Card. Developing countries proceeded from the manual and semiautomatic method of medical data processing to the new method of entering, storage, transfer, searching and protection of data using electronic equipment. Currently, many European countries have developed a Medical Card Based Electronic Information System. Both technologies offer the advantages and disadvantages. Three types of electronic card are currently in use: Hybrid Card, Smart Card and Laser Card. Hybrid Card offers characteristics of both Smart Card and Laser Card. The differences among these cards, such as a capacity, total price, price per byte, security system are discussed here. The dilemma is, which card should be used as a data carrier. The Electronic Family Registration Card is a question of strategic interest for B&H, but also a big investment. We should avoid the errors of other countries that have been developing card-based system. In this article we present all mentioned cards and compare advantages and disadvantages of different technologies.

  15. Registration of 3-dimensional facial photographs for clinical use.

    Science.gov (United States)

    Maal, Thomas J J; van Loon, Bram; Plooij, Joanneke M; Rangel, Frits; Ettema, Anke M; Borstlap, Wilfred A; Bergé, Stefaan J

    2010-10-01

    To objectively evaluate treatment outcomes in oral and maxillofacial surgery, pre- and post-treatment 3-dimensional (3D) photographs of the patient's face can be registered. For clinical use, it is of great importance that this registration process is accurate (photographs were captured at 3 different times: baseline (T(0)), after 1 minute (T(1)), and 3 weeks later (T(2)). Furthermore, a 3D photograph of the volunteer laughing (T(L)) was acquired to investigate the effect of facial expression. Two different registration methods were used to register the photographs acquired at all different times: surface-based registration and reference-based registration. Within the surface-based registration, 2 different software packages (Maxilim [Medicim NV, Mechelen, Belgium] and 3dMD Patient [3dMD LLC, Atlanta, GA]) were used to register the 3D photographs acquired at the various times. The surface-based registration process was repeated with the preprocessed photographs. Reference-based registration (Maxilim) was performed twice by 2 observers investigating the inter- and intraobserver error. The mean registration errors are small for the 3D photographs at rest (0.39 mm for T(0)-T(1) and 0.52 mm for T(0)-T(2)). The mean registration error increased to 1.2 mm for the registration between the 3D photographs acquired at T(0) and T(L). The mean registration error for the reference-based method was 1.0 mm for T(0)-T(1), 1.1 mm for T(0)-T(2), and 1.5 mm for T(0) and T(L). The mean registration errors for the preprocessed photographs were even smaller (0.30 mm for T(0)-T(1), 0.42 mm for T(0)-T(2), and 1.2 mm for T(0) and T(L)). Furthermore, a strong correlation between the results of both software packages used for surface-based registration was found. The intra- and interobserver error for the reference-based registration method was found to be 1.2 and 1.0 mm, respectively. Surface-based registration is an accurate method to compare 3D photographs of the same individual at

  16. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables

  17. Central research registration at Technical University of Denmark (DTU)

    DEFF Research Database (Denmark)

    Sand, Ane Ahrenkiel

    Some five years ago, DTU switched from decentralized research registration, where researchers entered their publications into the DTU research repository themselves to centralized research registration, whereby library staff upload academic publications to the repository on behalf...... up the registration team, the configuration of the repository platform (Pure), the registration workflow and last but not least the results since DTU switched to centralized research registration....

  18. Central Research Registration at Technical University of Denmark (DTU)

    DEFF Research Database (Denmark)

    Sand, Ane Ahrenkiel

    Some five years ago, DTU switched from decentralized research registration, where researchers entered their publications into the DTU research repository themselves to centralized research registration, whereby library staff upload academic publications to the repository on behalf...... up the registration team, the configuration of the repository platform (Pure), the registration workflow and last but not least the results since DTU switched to centralized research registration....

  19. Electronics Department. Progress Report 1984

    DEFF Research Database (Denmark)

    Risø National Laboratory, Roskilde

    This report summarizes the activities in the Electronics Department in 1984. These include work under the headings of informatics, applied laser physics, nuclear geophysics, instrumentation and measuring techniques, and instrumentation consulting, registration and maintenance for the Danish...

  20. Fuels Registration, Reporting, and Compliance Help

    Science.gov (United States)

    Information about the requirements for registration and health effects testing of new fuels or fuel additives and mandatory registration for fuels reporting and about mandatory reporting forms for parties regulated under EPA fuel programs.

  1. The cadastral registration of the property right

    Directory of Open Access Journals (Sweden)

    D.-G. IONAȘ

    2017-12-01

    Full Text Available Real rights are subjective patrimonial rights which provide the holder with the right to directly exercise certain prerogatives over a determined good. Real rights over immobile goods, registered in the cadastral register are called tabular rights. Cadastral registration is that certain form of registration by which a real right over an immobile good is acquired, changed or ended, from the time de registration request is filed. At this time, registration in the cadastral register provides the opposability effect, as the constitutive effect is suspended until the cadastral works are finalized and new cadastral registers are created for each administrative unit.

  2. Three dimensional image alignment, registration and fusion

    International Nuclear Information System (INIS)

    Treves, S.T.; Mitchell, K.D.; Habboush, I.H.

    1998-01-01

    Combined assessment of three dimensional anatomical and functional images (SPECT, PET, MRI, CT) is useful to determine the nature and extent of lesions in many parts of the body. Physicians principally rely on their spatial sense of mentally re-orient and overlap images obtained with different imaging modalities. Objective methods that enable easy and intuitive image registration can help the physician arrive at more optimal diagnoses and better treatment decisions. This review describes a simple, intuitive and robust image registration approach developed in our laboratory. It differs from most other registration techniques in that it allows the user to incorporate all of the available information within the images in the registration process. This method takes full advantage of the ability of knowledgeable operators to achieve image registration and fusion using an intuitive interactive visual approach. It can register images accurately and quickly without the use of elaborate mathematical modeling or optimization techniques. The method provides the operator with tools to manipulate images in three dimensions, including visual feedback techniques to assess the accuracy of registration (grids, overlays, masks, and fusion of images in different colors). Its application is not limited to brain imaging and can be applied to images from any region in the body. The overall effect is a registration algorithm that is easy to implement and can achieve accuracy on the order of one pixel

  3. Sulcal set optimization for cortical surface registration.

    Science.gov (United States)

    Joshi, Anand A; Pantazis, Dimitrios; Li, Quanzheng; Damasio, Hanna; Shattuck, David W; Toga, Arthur W; Leahy, Richard M

    2010-04-15

    Flat mapping based cortical surface registration constrained by manually traced sulcal curves has been widely used for inter subject comparisons of neuroanatomical data. Even for an experienced neuroanatomist, manual sulcal tracing can be quite time consuming, with the cost increasing with the number of sulcal curves used for registration. We present a method for estimation of an optimal subset of size N(C) from N possible candidate sulcal curves that minimizes a mean squared error metric over all combinations of N(C) curves. The resulting procedure allows us to estimate a subset with a reduced number of curves to be traced as part of the registration procedure leading to optimal use of manual labeling effort for registration. To minimize the error metric we analyze the correlation structure of the errors in the sulcal curves by modeling them as a multivariate Gaussian distribution. For a given subset of sulci used as constraints in surface registration, the proposed model estimates registration error based on the correlation structure of the sulcal errors. The optimal subset of constraint curves consists of the N(C) sulci that jointly minimize the estimated error variance for the subset of unconstrained curves conditioned on the N(C) constraint curves. The optimal subsets of sulci are presented and the estimated and actual registration errors for these subsets are computed. Copyright 2009 Elsevier Inc. All rights reserved.

  4. Open-Source Electronic Health Record Systems for Low-Resource Settings: Systematic Review.

    Science.gov (United States)

    Syzdykova, Assel; Malta, André; Zolfo, Maria; Diro, Ermias; Oliveira, José Luis

    2017-11-13

    Despite the great impact of information and communication technologies on clinical practice and on the quality of health services, this trend has been almost exclusive to developed countries, whereas countries with poor resources suffer from many economic and social issues that have hindered the real benefits of electronic health (eHealth) tools. As a component of eHealth systems, electronic health records (EHRs) play a fundamental role in patient management and effective medical care services. Thus, the adoption of EHRs in regions with a lack of infrastructure, untrained staff, and ill-equipped health care providers is an important task. However, the main barrier to adopting EHR software in low- and middle-income countries is the cost of its purchase and maintenance, which highlights the open-source approach as a good solution for these underserved areas. The aim of this study was to conduct a systematic review of open-source EHR systems based on the requirements and limitations of low-resource settings. First, we reviewed existing literature on the comparison of available open-source solutions. In close collaboration with the University of Gondar Hospital, Ethiopia, we identified common limitations in poor resource environments and also the main requirements that EHRs should support. Then, we extensively evaluated the current open-source EHR solutions, discussing their strengths and weaknesses, and their appropriateness to fulfill a predefined set of features relevant for low-resource settings. The evaluation methodology allowed assessment of several key aspects of available solutions that are as follows: (1) integrated applications, (2) configurable reports, (3) custom reports, (4) custom forms, (5) interoperability, (6) coding systems, (7) authentication methods, (8) patient portal, (9) access control model, (10) cryptographic features, (11) flexible data model, (12) offline support, (13) native client, (14) Web client,(15) other clients, (16) code

  5. A semi-automated 2D/3D marker-based registration algorithm modelling prostate shrinkage during radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Budiharto, Tom; Slagmolen, Pieter; Hermans, Jeroen; Maes, Frederik; Verstraete, Jan; Heuvel, Frank Van den; Depuydt, Tom; Oyen, Raymond; Haustermans, Karin

    2009-01-01

    Background and purpose: Currently, most available patient alignment tools based on implanted markers use manual marker matching and rigid registration transformations to measure the needed translational shifts. To quantify the particular effect of prostate gland shrinkage, implanted gold markers were tracked during a course of radiotherapy including an isotropic scaling factor to model prostate shrinkage. Materials and methods: Eight patients with prostate cancer had gold markers implanted transrectally and seven were treated with (neo) adjuvant androgen deprivation therapy. After patient alignment to skin tattoos, orthogonal electronic portal images (EPIs) were taken. A semi-automated 2D/3D marker-based registration was performed to calculate the necessary couch shifts. The registration consists of a rigid transformation combined with an isotropic scaling to model prostate shrinkage. Results: The inclusion of an isotropic shrinkage model in the registration algorithm cancelled the corresponding increase in registration error. The mean scaling factor was 0.89 ± 0.09. For all but two patients, a decrease of the isotropic scaling factor during treatment was observed. However, there was almost no difference in the translation offset between the manual matching of the EPIs to the digitally reconstructed radiographs and the semi-automated 2D/3D registration. A decrease in the intermarker distance was found correlating with prostate shrinkage rather than with random marker migration. Conclusions: Inclusion of shrinkage in the registration process reduces registration errors during a course of radiotherapy. Nevertheless, this did not lead to a clinically significant change in the proposed table translations when compared to translations obtained with manual marker matching without a scaling correction

  6. Subspace-Based Holistic Registration for Low-Resolution Facial Images

    Directory of Open Access Journals (Sweden)

    Boom BJ

    2010-01-01

    Full Text Available Subspace-based holistic registration is introduced as an alternative to landmark-based face registration, which has a poor performance on low-resolution images, as obtained in camera surveillance applications. The proposed registration method finds the alignment by maximizing the similarity score between a probe and a gallery image. We use a novel probabilistic framework for both user-independent as well as user-specific face registration. The similarity is calculated using the probability that the face image is correctly aligned in a face subspace, but additionally we take the probability into account that the face is misaligned based on the residual error in the dimensions perpendicular to the face subspace. We perform extensive experiments on the FRGCv2 database to evaluate the impact that the face registration methods have on face recognition. Subspace-based holistic registration on low-resolution images can improve face recognition in comparison with landmark-based registration on high-resolution images. The performance of the tested face recognition methods after subspace-based holistic registration on a low-resolution version of the FRGC database is similar to that after manual registration.

  7. 75 FR 80496 - Registration Review; Pesticide Dockets Opened for Review and Comment and Other Docket Actions

    Science.gov (United States)

    2010-12-22

    ... in hard copy form. Publicly available docket materials are available either in the electronic docket at http://www.regulations.gov , or, if only available in hard copy, at the OPP Regulatory Public... 155, subpart C. Section 3(g) of FIFRA provides, among other things, that the registrations of...

  8. 76 FR 38166 - Registration Review; Pesticide Dockets Opened for Review and Comment and Other Docket Actions

    Science.gov (United States)

    2011-06-29

    ... in hard copy form. Publicly available docket materials are available either in the electronic docket at http://www.regulations.gov , or, if only available in hard copy, at the OPP Regulatory Public.... Section 3(g) of FIFRA provides, among other things, that the registrations of pesticides are to be...

  9. Language proficiency and nursing registration.

    Science.gov (United States)

    Müller, Amanda

    2016-02-01

    This discussion paper focuses on English proficiency standards for nursing registration in Australia, how Australia has dealt with the issue of language proficiency, and the factors which have led to the establishment of the current language standards. Also, this paper will provide a comparison of the two language tests that are currently accepted in Australia (OET and IELTS), including the appropriateness of these tests and the minimum standards used. The paper will also examine the use of educational background as an indicator of language proficiency. Finally, communication-based complaints in the post-registration environment will be explored, and some discussion will be provided about why pre-registration measures might have failed to prevent such problematic situations from occurring. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. 48 CFR 52.204-7 - Central Contractor Registration.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Central Contractor....204-7 Central Contractor Registration. As prescribed in 4.1105, use the following clause: Central Contractor Registration (APR 2008) (a) Definitions. As used in this clause— Central Contractor Registration...

  11. Surface-to-surface registration using level sets

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Erbou, Søren G.; Vester-Christensen, Martin

    2007-01-01

    This paper presents a general approach for surface-to-surface registration (S2SR) with the Euclidean metric using signed distance maps. In addition, the method is symmetric such that the registration of a shape A to a shape B is identical to the registration of the shape B to the shape A. The S2SR...... problem can be approximated by the image registration (IR) problem of the signed distance maps (SDMs) of the surfaces confined to some narrow band. By shrinking the narrow bands around the zero level sets the solution to the IR problem converges towards the S2SR problem. It is our hypothesis...... that this approach is more robust and less prone to fall into local minima than ordinary surface-to-surface registration. The IR problem is solved using the inverse compositional algorithm. In this paper, a set of 40 pelvic bones of Duroc pigs are registered to each other w.r.t. the Euclidean transformation...

  12. Contacts in the Office of Pesticide Programs, Registration Division

    Science.gov (United States)

    The Registration Division (RD) is responsible product registrations, amendments, registrations, tolerances, experimental use permits, and emergency exemptions for conventional chemical pesticides. Find contacts in this division.

  13. Automatic intra-modality brain image registration method

    International Nuclear Information System (INIS)

    Whitaker, J.M.; Ardekani, B.A.; Braun, M.

    1996-01-01

    Full text: Registration of 3D images of brain of the same or different subjects has potential importance in clinical diagnosis, treatment planning and neurological research. The broad aim of our work is to produce an automatic and robust intra-modality, brain image registration algorithm for intra-subject and inter-subject studies. Our algorithm is composed of two stages. Initial alignment is achieved by finding the values of nine transformation parameters (representing translation, rotation and scale) that minimise the nonoverlapping regions of the head. This is achieved by minimisation of the sum of the exclusive OR of two binary head images, produced using the head extraction procedure described by Ardekani et al. (J Comput Assist Tomogr, 19:613-623, 1995). The initial alignment successfully determines the scale parameters and gross translation and rotation parameters. Fine alignment uses an objective function described for inter-modality registration in Ardekani et al. (ibid.). The algorithm segments one of the images to be aligned into a set of connected components using K-means clustering. Registration is achieved by minimising the K-means variance of the segmentation induced in the other image. Similarity of images of the same modality makes the method attractive for intra-modality registration. A 3D MR image, with voxel dimensions, 2x2x6 mm, was misaligned. The registered image shows visually accurate registration. The average displacement of a pixel from its correct location was measured to be 3.3 mm. The algorithm was tested on intra-subject MR images and was found to produce good qualitative results. Using the data available, the algorithm produced promising qualitative results in intra-subject registration. Further work is necessary in its application to intersubject registration, due to large variability in brain structure between subjects. Clinical evaluation of the algorithm for selected applications is required

  14. A prospective comparison between auto-registration and manual registration of real-time ultrasound with MR images for percutaneous ablation or biopsy of hepatic lesions.

    Science.gov (United States)

    Cha, Dong Ik; Lee, Min Woo; Song, Kyoung Doo; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga

    2017-06-01

    To compare the accuracy and required time for image fusion of real-time ultrasound (US) with pre-procedural magnetic resonance (MR) images between positioning auto-registration and manual registration for percutaneous radiofrequency ablation or biopsy of hepatic lesions. This prospective study was approved by the institutional review board, and all patients gave written informed consent. Twenty-two patients (male/female, n = 18/n = 4; age, 61.0 ± 7.7 years) who were referred for planning US to assess the feasibility of radiofrequency ablation (n = 21) or biopsy (n = 1) for focal hepatic lesions were included. One experienced radiologist performed the two types of image fusion methods in each patient. The performance of auto-registration and manual registration was evaluated. The accuracy of the two methods, based on measuring registration error, and the time required for image fusion for both methods were recorded using in-house software and respectively compared using the Wilcoxon signed rank test. Image fusion was successful in all patients. The registration error was not significantly different between the two methods (auto-registration: median, 3.75 mm; range, 1.0-15.8 mm vs. manual registration: median, 2.95 mm; range, 1.2-12.5 mm, p = 0.242). The time required for image fusion was significantly shorter with auto-registration than with manual registration (median, 28.5 s; range, 18-47 s, vs. median, 36.5 s; range, 14-105 s, p = 0.026). Positioning auto-registration showed promising results compared with manual registration, with similar accuracy and even shorter registration time.

  15. High performance deformable image registration algorithms for manycore processors

    CERN Document Server

    Shackleford, James; Sharp, Gregory

    2013-01-01

    High Performance Deformable Image Registration Algorithms for Manycore Processors develops highly data-parallel image registration algorithms suitable for use on modern multi-core architectures, including graphics processing units (GPUs). Focusing on deformable registration, we show how to develop data-parallel versions of the registration algorithm suitable for execution on the GPU. Image registration is the process of aligning two or more images into a common coordinate frame and is a fundamental step to be able to compare or fuse data obtained from different sensor measurements. E

  16. Visitor Registration System

    Data.gov (United States)

    US Agency for International Development — Visitor Registration System (VRS) streamlines visitor check-in and check-out process for expediting visitors into USAID. The system captures visitor information...

  17. 77 FR 18810 - Registration Review; Pesticide Dockets Opened for Review and Comment and Other Docket Act

    Science.gov (United States)

    2012-03-28

    ... and will be publicly available only in hard copy form. Publicly available docket materials are available either in the electronic docket at http://www.regulations.gov , or, if only available in hard copy.... Section 3(g) of FIFRA provides, among other things, that the registrations of pesticides are to be...

  18. 12 CFR 998.2 - Registration and periodic disclosures.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Registration and periodic disclosures. 998.2 Section 998.2 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOME LOAN BANK DISCLOSURES REGISTRATION OF FEDERAL HOME LOAN BANK EQUITY SECURITIES § 998.2 Registration and periodic disclosures. (a...

  19. 17 CFR 31.6 - Registration of leverage commodities.

    Science.gov (United States)

    2010-04-01

    ... taking delivery to buy or sell the leverage commodity; (2) Explain the effect of such changes upon the... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Registration of leverage... LEVERAGE TRANSACTIONS § 31.6 Registration of leverage commodities. (a) Registration of leverage commodities...

  20. A completely CAD/CAM individual transmission device for electronic mandible movement registration.

    Science.gov (United States)

    Krey, Karl-Friedrich; Kordaß, Bernd; Ruge, Sebastian

    The connection of a device for the registration of mandibular movements depends on the coupling of the teeth with a paraocclusal adapter. This is normally done by individualizing a prefabricated metal support, either directly on the patient or in the dental laboratory. The goal was to create an individual paraocclusal adapter by means of additive computer-assisted design/computer-assisted manufacturing (CAD/CAM) procedures, and to test it clinically. Starting from intraoral scans of the maxillary and mandibular teeth, an individual paraocclusal adapter was constructed by combining an adapter piece adapted to the tooth and jaw shape with a prefabricated standard part. This article describes step by step the design using the 3D CAD software, up until production by means of 3D printing. Initial clinical experience is also discussed.

  1. Evaluation of three electronic report processing systems for preparing hydrologic reports of the U.S Geological Survey, Water Resources Division

    Science.gov (United States)

    Stiltner, G.J.

    1990-01-01

    In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25

  2. 40 CFR 152.99 - Petitions to cancel registration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Petitions to cancel registration. 152... Submitters' Rights § 152.99 Petitions to cancel registration. An original data submitter may petition the Agency to deny or cancel the registration of a product in accordance with this section if he has...

  3. 49 CFR 107.503 - Registration statement.

    Science.gov (United States)

    2010-10-01

    ... tank motor vehicles which the registrant intends to manufacture, assemble, repair, inspect, test or... this section, each person who repairs a cargo tank or cargo tank motor vehicle must submit a copy of... PROGRAM PROCEDURES Registration of Cargo Tank and Cargo Tank Motor Vehicle Manufacturers, Assemblers...

  4. Use and User Perception of Electronic Information Resources: A Case Study of Siva Institute of Frontier Technology, India

    Directory of Open Access Journals (Sweden)

    Velmurugan Chandran

    2013-12-01

    Full Text Available The present study aims to explore the use and user perception of electronic resources in Siva Institute of Frontier Technology, India. A total number of 123 users were taken into account for the study through a questionnaire-based survey method. A well-structured questionnaire was designed and distributed to the selected 200 students and staff members. 123 copies of the questionnaires were returned dully filled in and the overall response rate was 61.50 percent. The questionnaire contained both open- and close-ended questions. The collected data were classified, analyzed, and tabulated by using simple statistical methods. This study covers the impact of electronic resources on students and faculty in their academic pursuit.

  5. A preliminary categorization of end-of-life electrical and electronic equipment as secondary metal resources

    International Nuclear Information System (INIS)

    Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi

    2011-01-01

    Highlights: → End-of-life electrical and electronic equipment (EEE) as secondary metal resources. → The content and the total amount of metals in specific equipment are both important. → We categorized 21 EEE types from contents and total amounts of various metals. → Important equipment types as secondary resources were listed for each metal kind. → Collectability and possible collection systems of various EEE types were discussed. - Abstract: End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection

  6. 32 CFR 636.9 - Registration requirement.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Registration requirement. 636.9 Section 636.9 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION (SPECIFIC INSTALLATIONS) Fort Stewart, Georgia § 636.9 Registration requirement. In...

  7. Fast fluid registration of medical images

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Gramkow, Claus

    1996-01-01

    This paper offers a new fast algorithm for non-rigid viscous fluid registration of medical images that is at least an order of magnitude faster than the previous method by (Christensen et al., 1994). The core algorithm in the fluid registration method is based on a linear elastic deformation...

  8. Geometric registration of remotely sensed data with SAMIR

    Science.gov (United States)

    Gianinetto, Marco; Barazzetti, Luigi; Dini, Luigi; Fusiello, Andrea; Toldo, Roberto

    2015-06-01

    The commercial market offers several software packages for the registration of remotely sensed data through standard one-to-one image matching. Although very rapid and simple, this strategy does not take into consideration all the interconnections among the images of a multi-temporal data set. This paper presents a new scientific software, called Satellite Automatic Multi-Image Registration (SAMIR), able to extend the traditional registration approach towards multi-image global processing. Tests carried out with high-resolution optical (IKONOS) and high-resolution radar (COSMO-SkyMed) data showed that SAMIR can improve the registration phase with a more rigorous and robust workflow without initial approximations, user's interaction or limitation in spatial/spectral data size. The validation highlighted a sub-pixel accuracy in image co-registration for the considered imaging technologies, including optical and radar imagery.

  9. Principles of formation of the content of an educational electronic resource on the basis of general and didactic patterns of learning

    Directory of Open Access Journals (Sweden)

    Ольга Юрьевна Заславская

    2018-12-01

    Full Text Available The article considers the influence of the development of technical means of teaching on the effectiveness of educational and methodical resources. Modern opportunities of information and communication technologies allow creating electronic educational resources that represent educational information that automates the learning process, provide information assistance, if necessary, collect and process statistical information on the degree of development of the content of the school material by schoolchildren, set an individual trajectory of learning, and so on. The main principle of data organization is the division of the training course into separate sections on the thematic elements and components of the learning process. General regularities include laws that encompass the entire didactic system, and in specific (particular cases, those whose actions extend to a separate component (aspect of the system. From the standpoint of the existence of three types of electronic training modules in the aggregate content of the electronic learning resource - information, control and module of practical classes - the principles of the formation of the electronic learning resource, in our opinion, should regulate all these components. Each of the certain principles is considered in the groups: scientific orientation, methodological orientation, systemic nature, accounting of interdisciplinary connections, fundamentalization, systematic and dosage sequence, rational use of study time, accessibility, minimization, operationalization of goals, unified identification diagnosis.

  10. Electronics Department progress report 1984

    International Nuclear Information System (INIS)

    1985-11-01

    This report summarizes the activities in the Electronics Department in 1984. These include work under the headings of informatics, applied laser physics, nuclear geophysics, instrumentation and measuring techniques, and instrumentation consulting, registration and maintenance for the Danish Research Council and Risoe National Laboratory. (author)

  11. Registration in the Danish Regional Nonmelanoma Skin Cancer Dermatology Database: completeness of registration and accuracy of key variables

    Directory of Open Access Journals (Sweden)

    Anna L Lamberg

    2010-05-01

    Full Text Available Anna L Lamberg1, Deirdre Cronin-Fenton2, Anne B Olesen11Department of Dermatology, 2Department of Clinical Epidemiology, Aarhus University Hospital, Aarhus, C, DenmarkObjective: To validate a clinical database for nonmelanoma skin cancer (NMSC with the aim of monitoring and predicting the prognosis of NMSC treated by dermatologists in clinics in the central and north Denmark regions.Methods: We assessed the completeness of registration of patients and follow-up visits, and positive predictive value (PPV, negative predictive value (NPV, sensitivity, and specificity of registrations in the database. We used the Danish Pathology Registry (DPR (n = 288 and a review of randomly selected medical records (n = 67 from two clinics as gold standards.Results: The completeness of registration of patients was 62% and 76% with DPR and medical record review as gold standards, respectively. The completeness of registration of 1st and 2nd follow up visits was 85% and 69%, respectively. The PPV and NPV ranged from 85% to 99%, and the sensitivity and specificity from 67% to 100%.Conclusion: Overall, the accuracy of variables registered in the NMSC database was satisfactory but completeness of patient registration and follow-up visits were modest. The NMSC database is a potentially valuable tool for monitoring and facilitating improvement of NMSC treatment in dermatology clinics. However, there is still room for improvement of registration of both patients and their follow-up visits.Keywords: nonmelanoma skin cancer, validation, database, positive predictive value, completeness

  12. 27 CFR 25.112 - Dealer registration.

    Science.gov (United States)

    2010-04-01

    .... Every brewer who sells, or offers for sale, any alcohol product (distilled spirits, wines, or beer) fit... registration. Registration covers all sales from the same location, including sales of wine, spirits, or other... for making sales of wine or beer at the customer's place of business. Otherwise, a brewer who conducts...

  13. 19 CFR 360.102 - Online registration.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Online registration. 360.102 Section 360.102... ANALYSIS SYSTEM § 360.102 Online registration. (a) In general. (1) Any importer, importing company, customs.... boxes will not be accepted. A user identification number will be issued within two business days...

  14. Survey of Non-Rigid Registration Tools in Medicine.

    Science.gov (United States)

    Keszei, András P; Berkels, Benjamin; Deserno, Thomas M

    2017-02-01

    We catalogue available software solutions for non-rigid image registration to support scientists in selecting suitable tools for specific medical registration purposes. Registration tools were identified using non-systematic search in Pubmed, Web of Science, IEEE Xplore® Digital Library, Google Scholar, and through references in identified sources (n = 22). Exclusions are due to unavailability or inappropriateness. The remaining (n = 18) tools were classified by (i) access and technology, (ii) interfaces and application, (iii) living community, (iv) supported file formats, and (v) types of registration methodologies emphasizing the similarity measures implemented. Out of the 18 tools, (i) 12 are open source, 8 are released under a permissive free license, which imposes the least restrictions on the use and further development of the tool, 8 provide graphical processing unit (GPU) support; (ii) 7 are built on software platforms, 5 were developed for brain image registration; (iii) 6 are under active development but only 3 have had their last update in 2015 or 2016; (iv) 16 support the Analyze format, while 7 file formats can be read with only one of the tools; and (v) 6 provide multiple registration methods and 6 provide landmark-based registration methods. Based on open source, licensing, GPU support, active community, several file formats, algorithms, and similarity measures, the tools Elastics and Plastimatch are chosen for the platform ITK and without platform requirements, respectively. Researchers in medical image analysis already have a large choice of registration tools freely available. However, the most recently published algorithms may not be included in the tools, yet.

  15. Wavelet based free-form deformations for nonrigid registration

    Science.gov (United States)

    Sun, Wei; Niessen, Wiro J.; Klein, Stefan

    2014-03-01

    In nonrigid registration, deformations may take place on the coarse and fine scales. For the conventional B-splines based free-form deformation (FFD) registration, these coarse- and fine-scale deformations are all represented by basis functions of a single scale. Meanwhile, wavelets have been proposed as a signal representation suitable for multi-scale problems. Wavelet analysis leads to a unique decomposition of a signal into its coarse- and fine-scale components. Potentially, this could therefore be useful for image registration. In this work, we investigate whether a wavelet-based FFD model has advantages for nonrigid image registration. We use a B-splines based wavelet, as defined by Cai and Wang.1 This wavelet is expressed as a linear combination of B-spline basis functions. Derived from the original B-spline function, this wavelet is smooth, differentiable, and compactly supported. The basis functions of this wavelet are orthogonal across scales in Sobolev space. This wavelet was previously used for registration in computer vision, in 2D optical flow problems,2 but it was not compared with the conventional B-spline FFD in medical image registration problems. An advantage of choosing this B-splines based wavelet model is that the space of allowable deformation is exactly equivalent to that of the traditional B-spline. The wavelet transformation is essentially a (linear) reparameterization of the B-spline transformation model. Experiments on 10 CT lung and 18 T1-weighted MRI brain datasets show that wavelet based registration leads to smoother deformation fields than traditional B-splines based registration, while achieving better accuracy.

  16. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-05-17

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables and challenges as well as lessons learnt by the Project Team.

  17. Efficient Variational Approaches for Deformable Registration of Images

    Directory of Open Access Journals (Sweden)

    Mehmet Ali Akinlar

    2012-01-01

    Full Text Available Dirichlet, anisotropic, and Huber regularization terms are presented for efficient registration of deformable images. Image registration, an ill-posed optimization problem, is solved using a gradient-descent-based method and some fundamental theorems in calculus of variations. Euler-Lagrange equations with homogeneous Neumann boundary conditions are obtained. These equations are discretized by multigrid and finite difference numerical techniques. The method is applied to the registration of brain MR images of size 65×65. Computational results indicate that the presented method is quite fast and efficient in the registration of deformable medical images.

  18. 21 CFR 1309.45 - Extension of registration pending final order.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Extension of registration pending final order. 1309.45 Section 1309.45 Food and Drugs DRUG ENFORCEMENT ADMINISTRATION, DEPARTMENT OF JUSTICE... for Registration: Revocation Or Suspension of Registration § 1309.45 Extension of registration pending...

  19. 32 CFR 636.8 - Registration policy.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Registration policy. 636.8 Section 636.8 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION (SPECIFIC INSTALLATIONS) Fort Stewart, Georgia § 636.8 Registration policy. In addition to th...

  20. Real-time CT-video registration for continuous endoscopic guidance

    Science.gov (United States)

    Merritt, Scott A.; Rai, Lav; Higgins, William E.

    2006-03-01

    Previous research has shown that CT-image-based guidance could be useful for the bronchoscopic assessment of lung cancer. This research drew upon the registration of bronchoscopic video images to CT-based endoluminal renderings of the airway tree. The proposed methods either were restricted to discrete single-frame registration, which took several seconds to complete, or required non-real-time buffering and processing of video sequences. We have devised a fast 2D/3D image registration method that performs single-frame CT-Video registration in under 1/15th of a second. This allows the method to be used for real-time registration at full video frame rates without significantly altering the physician's behavior. The method achieves its speed through a gradient-based optimization method that allows most of the computation to be performed off-line. During live registration, the optimization iteratively steps toward the locally optimal viewpoint at which a CT-based endoluminal view is most similar to a current bronchoscopic video frame. After an initial registration to begin the process (generally done in the trachea for bronchoscopy), subsequent registrations are performed in real-time on each incoming video frame. As each new bronchoscopic video frame becomes available, the current optimization is initialized using the previous frame's optimization result, allowing continuous guidance to proceed without manual re-initialization. Tests were performed using both synthetic and pre-recorded bronchoscopic video. The results show that the method is robust to initialization errors, that registration accuracy is high, and that continuous registration can proceed on real-time video at >15 frames per sec. with minimal user-intervention.

  1. elastix: a toolbox for intensity-based medical image registration.

    Science.gov (United States)

    Klein, Stefan; Staring, Marius; Murphy, Keelin; Viergever, Max A; Pluim, Josien P W

    2010-01-01

    Medical image registration is an important task in medical image processing. It refers to the process of aligning data sets, possibly from different modalities (e.g., magnetic resonance and computed tomography), different time points (e.g., follow-up scans), and/or different subjects (in case of population studies). A large number of methods for image registration are described in the literature. Unfortunately, there is not one method that works for all applications. We have therefore developed elastix, a publicly available computer program for intensity-based medical image registration. The software consists of a collection of algorithms that are commonly used to solve medical image registration problems. The modular design of elastix allows the user to quickly configure, test, and compare different registration methods for a specific application. The command-line interface enables automated processing of large numbers of data sets, by means of scripting. The usage of elastix for comparing different registration methods is illustrated with three example experiments, in which individual components of the registration method are varied.

  2. COMPARISON OF VOLUMETRIC REGISTRATION ALGORITHMS FOR TENSOR-BASED MORPHOMETRY.

    Science.gov (United States)

    Villalon, Julio; Joshi, Anand A; Toga, Arthur W; Thompson, Paul M

    2011-01-01

    Nonlinear registration of brain MRI scans is often used to quantify morphological differences associated with disease or genetic factors. Recently, surface-guided fully 3D volumetric registrations have been developed that combine intensity-guided volume registrations with cortical surface constraints. In this paper, we compare one such algorithm to two popular high-dimensional volumetric registration methods: large-deformation viscous fluid registration, formulated in a Riemannian framework, and the diffeomorphic "Demons" algorithm. We performed an objective morphometric comparison, by using a large MRI dataset from 340 young adult twin subjects to examine 3D patterns of correlations in anatomical volumes. Surface-constrained volume registration gave greater effect sizes for detecting morphometric associations near the cortex, while the other two approaches gave greater effects sizes subcortically. These findings suggest novel ways to combine the advantages of multiple methods in the future.

  3. The Synthesis of the Hierarchical Structure of Information Resources for Management of Electronic Commerce Entities

    Directory of Open Access Journals (Sweden)

    Krutova Anzhelika S.

    2017-06-01

    Full Text Available The aim of the article is to develop the theoretical bases for the classification and coding of economic information and the scientific justification of the content of information resources of an electronic commerce enterprise. The essence of information resources for management of electronic business entities is investigated. It is proved that the organization of accounting in e-commerce systems is advisable to be built on the basis of two circuits: accounting for financial flows and accounting associated with transformation of business factors in products and services as a result of production activities. There presented a sequence of accounting organization that allows to combine the both circuits in a single information system, which provides a possibility for the integrated replenishment and distributed simultaneous use of the e-commerce system by all groups of users. It is proved that the guarantee of efficient activity of the information management system of electronic commerce entities is a proper systematization of the aggregate of information resources on economic facts and operations of an enterprise in accordance with the management tasks by building the hierarchy of accounting nomenclatures. It is suggested to understand nomenclature as an objective, primary information aggregate concerning a certain fact of the economic activity of an enterprise, which is characterized by minimum requisites, is entered into the database of the information system and is to be reflected in the accounting system. It is proposed to build a database of e-commerce systems as a part of directories (constants, personnel, goods / products, suppliers, buyers and the hierarchy of accounting nomenclatures. The package of documents regulating the organization of accounting at an enterprise should include: the provision on the accounting services, the order on the accounting policy, the job descriptions, the schedules of information exchange, the report card and

  4. Study of national registration systems for health records of radiation workers. National radiation dose registration system

    International Nuclear Information System (INIS)

    Nakagawa, Haruo; Kanda, Keiji

    1999-01-01

    A national radiation dose registration system is proposed in this paper. In Japan, only one radiation dose registration system is partly effective. It is applied for workers in nuclear power plants which are under control of regulatory laws for nuclear reactors. The total system was proposed previously by the Committee for Compensation Claims of Nuclear Accidents. The reason for the delay in establishing a registration system for all radiation workers is supposedly a lack of effort to adjust differences among items in radiation protection laws and the promotion of public acceptance to atomic power. Items about dose recordings, record keeping and dose-record reporting in all of the radiation regulatory laws are compared to each other, and items were extracted for revision. (author)

  5. Evaluation of the use of registration stickers.

    Science.gov (United States)

    2011-04-01

    This research evaluated the potential costs and benefits of doing away with license plate registration stickers as part : of the registration renewal process for Pennsylvania. The research consisted of a comprehensive literature review, a : survey of...

  6. Deformable image registration using convolutional neural networks

    Science.gov (United States)

    Eppenhof, Koen A. J.; Lafarge, Maxime W.; Moeskops, Pim; Veta, Mitko; Pluim, Josien P. W.

    2018-03-01

    Deformable image registration can be time-consuming and often needs extensive parameterization to perform well on a specific application. We present a step towards a registration framework based on a three-dimensional convolutional neural network. The network directly learns transformations between pairs of three-dimensional images. The outputs of the network are three maps for the x, y, and z components of a thin plate spline transformation grid. The network is trained on synthetic random transformations, which are applied to a small set of representative images for the desired application. Training therefore does not require manually annotated ground truth deformation information. The methodology is demonstrated on public data sets of inspiration-expiration lung CT image pairs, which come with annotated corresponding landmarks for evaluation of the registration accuracy. Advantages of this methodology are its fast registration times and its minimal parameterization.

  7. Behaviors study of image registration algorithms in image guided radiation therapy

    International Nuclear Information System (INIS)

    Zou Lian; Hou Qing

    2008-01-01

    Objective: Study the behaviors of image registration algorithms, and analyze the elements which influence the performance of image registrations. Methods: Pre-known corresponding coordinates were appointed for reference image and moving image, and then the influence of region of interest (ROI) selection, transformation function initial parameters and coupled parameter spaces on registration results were studied with a software platform developed in home. Results: Region of interest selection had a manifest influence on registration performance. An improperly chosen ROI resulted in a bad registration. Transformation function initial parameters selection based on pre-known information could improve the accuracy of image registration. Coupled parameter spaces would enhance the dependence of image registration algorithm on ROI selection. Conclusions: It is necessary for clinic IGRT to obtain a ROI selection strategy (depending on specific commercial software) correlated to tumor sites. Three suggestions for image registration technique developers are automatic selection of the initial parameters of transformation function based on pre-known information, developing specific image registration algorithm for specific image feature, and assembling real-time image registration algorithms according to tumor sites selected by software user. (authors)

  8. Avoiding Stair-Step Artifacts in Image Registration for GOES-R Navigation and Registration Assessment

    Science.gov (United States)

    Grycewicz, Thomas J.; Tan, Bin; Isaacson, Peter J.; De Luccia, Frank J.; Dellomo, John

    2016-01-01

    In developing software for independent verification and validation (IVV) of the Image Navigation and Registration (INR) capability for the Geostationary Operational Environmental Satellite R Series (GOES-R) Advanced Baseline Imager (ABI), we have encountered an image registration artifact which limits the accuracy of image offset estimation at the subpixel scale using image correlation. Where the two images to be registered have the same pixel size, subpixel image registration preferentially selects registration values where the image pixel boundaries are close to lined up. Because of the shape of a curve plotting input displacement to estimated offset, we call this a stair-step artifact. When one image is at a higher resolution than the other, the stair-step artifact is minimized by correlating at the higher resolution. For validating ABI image navigation, GOES-R images are correlated with Landsat-based ground truth maps. To create the ground truth map, the Landsat image is first transformed to the perspective seen from the GOES-R satellite, and then is scaled to an appropriate pixel size. Minimizing processing time motivates choosing the map pixels to be the same size as the GOES-R pixels. At this pixel size image processing of the shift estimate is efficient, but the stair-step artifact is present. If the map pixel is very small, stair-step is not a problem, but image correlation is computation-intensive. This paper describes simulation-based selection of the scale for truth maps for registering GOES-R ABI images.

  9. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2015-06-16

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes pre-determining an association of the restricted computer resource and computer-resource-proximal environmental information. Indicia of user-proximal environmental information are received from a user requesting access to the restricted computer resource. Received indicia of user-proximal environmental information are compared to associated computer-resource-proximal environmental information. User access to the restricted computer resource is selectively granted responsive to a favorable comparison in which the user-proximal environmental information is sufficiently similar to the computer-resource proximal environmental information. In at least some embodiments, the process further includes comparing user-supplied biometric measure and comparing it with a predetermined association of at least one biometric measure of an authorized user. Access to the restricted computer resource is granted in response to a favorable comparison.

  10. Intensity-based hierarchical elastic registration using approximating splines.

    Science.gov (United States)

    Serifovic-Trbalic, Amira; Demirovic, Damir; Cattin, Philippe C

    2014-01-01

    We introduce a new hierarchical approach for elastic medical image registration using approximating splines. In order to obtain the dense deformation field, we employ Gaussian elastic body splines (GEBS) that incorporate anisotropic landmark errors and rotation information. Since the GEBS approach is based on a physical model in form of analytical solutions of the Navier equation, it can very well cope with the local as well as global deformations present in the images by varying the standard deviation of the Gaussian forces. The proposed GEBS approximating model is integrated into the elastic hierarchical image registration framework, which decomposes a nonrigid registration problem into numerous local rigid transformations. The approximating GEBS registration scheme incorporates anisotropic landmark errors as well as rotation information. The anisotropic landmark localization uncertainties can be estimated directly from the image data, and in this case, they represent the minimal stochastic localization error, i.e., the Cramér-Rao bound. The rotation information of each landmark obtained from the hierarchical procedure is transposed in an additional angular landmark, doubling the number of landmarks in the GEBS model. The modified hierarchical registration using the approximating GEBS model is applied to register 161 image pairs from a digital mammogram database. The obtained results are very encouraging, and the proposed approach significantly improved all registrations comparing the mean-square error in relation to approximating TPS with the rotation information. On artificially deformed breast images, the newly proposed method performed better than the state-of-the-art registration algorithm introduced by Rueckert et al. (IEEE Trans Med Imaging 18:712-721, 1999). The average error per breast tissue pixel was less than 2.23 pixels compared to 2.46 pixels for Rueckert's method. The proposed hierarchical elastic image registration approach incorporates the GEBS

  11. Registration accuracy and quality of real-life images.

    Directory of Open Access Journals (Sweden)

    Wei-Yen Hsu

    Full Text Available BACKGROUND: A common registration problem for the application of consumer device is to align all the acquired image sequences into a complete scene. Image alignment requires a registration algorithm that will compensate as much as possible for geometric variability among images. However, images captured views from a real scene usually produce different distortions. Some are derived from the optic characteristics of image sensors, and others are caused by the specific scenes and objects. METHODOLOGY/PRINCIPAL FINDINGS: An image registration algorithm considering the perspective projection is proposed for the application of consumer devices in this study. It exploits a multiresolution wavelet-based method to extract significant features. An analytic differential approach is then proposed to achieve fast convergence of point matching. Finally, the registration accuracy is further refined to obtain subpixel precision by a feature-based modified Levenberg-Marquardt method. Due to its feature-based and nonlinear characteristic, it converges considerably faster than most other methods. In addition, vignette compensation and color difference adjustment are also performed to further improve the quality of registration results. CONCLUSIONS/SIGNIFICANCE: The performance of the proposed method is evaluated by testing the synthetic and real images acquired by a hand-held digital still camera and in comparison with two registration techniques in terms of the squared sum of intensity differences (SSD and correlation coefficient (CC. The results indicate that the proposed method is promising in registration accuracy and quality, which are statistically significantly better than other two approaches.

  12. 78 FR 20326 - Draft Compliance Policy Guide Sec. 100.250 Food Facility Registration-Human and Animal Food...

    Science.gov (United States)

    2013-04-04

    ... before it begins work on the final version of the CPG, submit either electronic or written comments on... reasonable probability of causing serious adverse health consequences or death to humans or animals, FDA may... registration. The draft CPG also contains information that may be useful for the regulated industry and to the...

  13. Robust inverse-consistent affine CT-MR registration in MRI-assisted and MRI-alone prostate radiation therapy.

    Science.gov (United States)

    Rivest-Hénault, David; Dowson, Nicholas; Greer, Peter B; Fripp, Jurgen; Dowling, Jason A

    2015-07-01

    CT-MR registration is a critical component of many radiation oncology protocols. In prostate external beam radiation therapy, it allows the propagation of MR-derived contours to reference CT images at the planning stage, and it enables dose mapping during dosimetry studies. The use of carefully registered CT-MR atlases allows the estimation of patient specific electron density maps from MRI scans, enabling MRI-alone radiation therapy planning and treatment adaptation. In all cases, the precision and accuracy achieved by registration influences the quality of the entire process. Most current registration algorithms do not robustly generalize and lack inverse-consistency, increasing the risk of human error and acting as a source of bias in studies where information is propagated in a particular direction, e.g. CT to MR or vice versa. In MRI-based treatment planning where both CT and MR scans serve as spatial references, inverse-consistency is critical, if under-acknowledged. A robust, inverse-consistent, rigid/affine registration algorithm that is well suited to CT-MR alignment in prostate radiation therapy is presented. The presented method is based on a robust block-matching optimization process that utilises a half-way space definition to maintain inverse-consistency. Inverse-consistency substantially reduces the influence of the order of input images, simplifying analysis, and increasing robustness. An open source implementation is available online at http://aehrc.github.io/Mirorr/. Experimental results on a challenging 35 CT-MR pelvis dataset demonstrate that the proposed method is more accurate than other popular registration packages and is at least as accurate as the state of the art, while being more robust and having an order of magnitude higher inverse-consistency than competing approaches. The presented results demonstrate that the proposed registration algorithm is readily applicable to prostate radiation therapy planning. Copyright © 2015. Published by

  14. Deformable image registration using convolutional neural networks

    NARCIS (Netherlands)

    Eppenhof, Koen A.J.; Lafarge, Maxime W.; Moeskops, Pim; Veta, Mitko; Pluim, Josien P.W.

    2018-01-01

    Deformable image registration can be time-consuming and often needs extensive parameterization to perform well on a specific application. We present a step towards a registration framework based on a three-dimensional convolutional neural network. The network directly learns transformations between

  15. Electronic theses and dissertations: a review of this valuable resource for nurse scholars worldwide.

    Science.gov (United States)

    Goodfellow, L M

    2009-06-01

    A worldwide repository of electronic theses and dissertations (ETDs) could provide worldwide access to the most up-to-date research generated by masters and doctoral students. Until that international repository is established, it is possible to access some of these valuable knowledge resources. ETDs provide a technologically advanced medium with endless multimedia capabilities that far exceed the print and bound copies of theses and dissertations housed traditionally in individual university libraries. CURRENT USE: A growing trend exists for universities worldwide to require graduate students to submit theses or dissertations as electronic documents. However, nurse scholars underutilize ETDs, as evidenced by perusing bibliographic citation lists in many of the research journals. ETDs can be searched for and retrieved through several digital resources such as the Networked Digital Library of Theses and Dissertations (http://www.ndltd.org), ProQuest Dissertations and Theses (http://www.umi.com), the Australasian Digital Theses Program (http://adt.caul.edu.au/) and through individual university web sites and online catalogues. An international repository of ETDs benefits the community of nurse scholars in many ways. The ability to access recent graduate students' research electronically from anywhere in the world is advantageous. For scholars residing in developing countries, access to these ETDs may prove to be even more valuable. In some cases, ETDs are not available for worldwide access and can only be accessed through the university library from which the student graduated. Public access to university library ETD collections is not always permitted. Nurse scholars from both developing and developed countries could benefit from ETDs.

  16. Elastic Versus Rigid Image Registration in Magnetic Resonance Imaging-transrectal Ultrasound Fusion Prostate Biopsy: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Venderink, Wulphert; de Rooij, Maarten; Sedelaar, J P Michiel; Huisman, Henkjan J; Fütterer, Jurgen J

    2016-07-29

    The main difference between the available magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion platforms for prostate biopsy is the method of image registration being either rigid or elastic. As elastic registration compensates for possible deformation caused by the introduction of an ultrasound probe for example, it is expected that it would perform better than rigid registration. The aim of this meta-analysis is to compare rigid with elastic registration by calculating the detection odds ratio (OR) for both subgroups. The detection OR is defined as the ratio of the odds of detecting clinically significant prostate cancer (csPCa) by MRI-TRUS fusion biopsy compared with systematic TRUS biopsy. Secondary objectives were the OR for any PCa and the OR after pooling both registration techniques. The electronic databases PubMed, Embase, and Cochrane were systematically searched for relevant studies according to the Preferred Reporting Items for Systematic Review and Meta-analysis Statement. Studies comparing MRI-TRUS fusion and systematic TRUS-guided biopsies in the same patient were included. The quality assessment of included studies was performed using the Quality Assessment of Diagnostic Accuracy Studies version 2. Eleven papers describing elastic and 10 describing rigid registration were included. Meta-analysis showed an OR of csPCa for elastic and rigid registration of 1.45 (95% confidence interval [CI]: 1.21-1.73, pimaging-transrectal ultrasound fusion systems which vary in their method of compensating for prostate deformation. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  17. The role of image registration in brain mapping

    Science.gov (United States)

    Toga, A.W.; Thompson, P.M.

    2008-01-01

    Image registration is a key step in a great variety of biomedical imaging applications. It provides the ability to geometrically align one dataset with another, and is a prerequisite for all imaging applications that compare datasets across subjects, imaging modalities, or across time. Registration algorithms also enable the pooling and comparison of experimental findings across laboratories, the construction of population-based brain atlases, and the creation of systems to detect group patterns in structural and functional imaging data. We review the major types of registration approaches used in brain imaging today. We focus on their conceptual basis, the underlying mathematics, and their strengths and weaknesses in different contexts. We describe the major goals of registration, including data fusion, quantification of change, automated image segmentation and labeling, shape measurement, and pathology detection. We indicate that registration algorithms have great potential when used in conjunction with a digital brain atlas, which acts as a reference system in which brain images can be compared for statistical analysis. The resulting armory of registration approaches is fundamental to medical image analysis, and in a brain mapping context provides a means to elucidate clinical, demographic, or functional trends in the anatomy or physiology of the brain. PMID:19890483

  18. Library resources on the Internet

    Science.gov (United States)

    Buchanan, Nancy L.

    1995-07-01

    Library resources are prevalent on the Internet. Library catalogs, electronic books, electronic periodicals, periodical indexes, reference sources, and U.S. Government documents are available by telnet, Gopher, World Wide Web, and FTP. Comparatively few copyrighted library resources are available freely on the Internet. Internet implementations of library resources can add useful features, such as full-text searching. There are discussion lists, Gophers, and World Wide Web pages to help users keep up with new resources and changes to existing ones. The future will bring more library resources, more types of library resources, and more integrated implementations of such resources to the Internet.

  19. Multimodality image registration with software: state-of-the-art

    International Nuclear Information System (INIS)

    Slomka, Piotr J.; Baum, Richard P.

    2009-01-01

    Multimodality image integration of functional and anatomical data can be performed by means of dedicated hybrid imaging systems or by software image co-registration techniques. Hybrid positron emission tomography (PET)/computed tomography (CT) systems have found wide acceptance in oncological imaging, while software registration techniques have a significant role in patient-specific, cost-effective, and radiation dose-effective application of integrated imaging. Software techniques allow accurate (2-3 mm) rigid image registration of brain PET with CT and MRI. Nonlinear techniques are used in whole-body image registration, and recent developments allow for significantly accelerated computing times. Nonlinear software registration of PET with CT or MRI is required for multimodality radiation planning. Difficulties remain in the validation of nonlinear registration of soft tissue organs. The utilization of software-based multimodality image integration in a clinical environment is sometimes hindered by the lack of appropriate picture archiving and communication systems (PACS) infrastructure needed to efficiently and automatically integrate all available images into one common database. In cardiology applications, multimodality PET/single photon emission computed tomography and coronary CT angiography imaging is typically not required unless the results of one of the tests are equivocal. Software image registration is likely to be used in a complementary fashion with hybrid PET/CT or PET/magnetic resonance imaging systems. Software registration of stand-alone scans ''paved the way'' for the clinical application of hybrid scanners, demonstrating practical benefits of image integration before the hybrid dual-modality devices were available. (orig.)

  20. 76 FR 27898 - Registration and Recordation Program

    Science.gov (United States)

    2011-05-13

    ... to reflect a reorganization that has moved the Recordation function from the Visual Arts and... function from the Visual Arts and Recordation Division of the Registration and Recordation Program to the... Visual Arts Division of the Registration and Recordation Program, has been renamed the Recordation...

  1. On combining algorithms for deformable image registration

    NARCIS (Netherlands)

    Muenzing, S.E.A.; Ginneken, van B.; Pluim, J.P.W.; Dawant, B.M.

    2012-01-01

    We propose a meta-algorithm for registration improvement by combining deformable image registrations (MetaReg). It is inspired by a well-established method from machine learning, the combination of classifiers. MetaReg consists of two main components: (1) A strategy for composing an improved

  2. Numerical methods for image registration

    CERN Document Server

    Modersitzki, Jan

    2003-01-01

    Based on the author's lecture notes and research, this well-illustrated and comprehensive text is one of the first to provide an introduction to image registration with particular emphasis on numerical methods in medical imaging. Ideal for researchers in industry and academia, it is also a suitable study guide for graduate mathematicians, computer scientists, engineers, medical physicists, and radiologists.Image registration is utilised whenever information obtained from different viewpoints needs to be combined or compared and unwanted distortion needs to be eliminated. For example, CCTV imag

  3. Propagation of registration uncertainty during multi-fraction cervical cancer brachytherapy

    Science.gov (United States)

    Amir-Khalili, A.; Hamarneh, G.; Zakariaee, R.; Spadinger, I.; Abugharbieh, R.

    2017-10-01

    Multi-fraction cervical cancer brachytherapy is a form of image-guided radiotherapy that heavily relies on 3D imaging during treatment planning, delivery, and quality control. In this context, deformable image registration can increase the accuracy of dosimetric evaluations, provided that one can account for the uncertainties associated with the registration process. To enable such capability, we propose a mathematical framework that first estimates the registration uncertainty and subsequently propagates the effects of the computed uncertainties from the registration stage through to the visualizations, organ segmentations, and dosimetric evaluations. To ensure the practicality of our proposed framework in real world image-guided radiotherapy contexts, we implemented our technique via a computationally efficient and generalizable algorithm that is compatible with existing deformable image registration software. In our clinical context of fractionated cervical cancer brachytherapy, we perform a retrospective analysis on 37 patients and present evidence that our proposed methodology for computing and propagating registration uncertainties may be beneficial during therapy planning and quality control. Specifically, we quantify and visualize the influence of registration uncertainty on dosimetric analysis during the computation of the total accumulated radiation dose on the bladder wall. We further show how registration uncertainty may be leveraged into enhanced visualizations that depict the quality of the registration and highlight potential deviations from the treatment plan prior to the delivery of radiation treatment. Finally, we show that we can improve the transfer of delineated volumetric organ segmentation labels from one fraction to the next by encoding the computed registration uncertainties into the segmentation labels.

  4. Feature-Based Retinal Image Registration Using D-Saddle Feature

    Directory of Open Access Journals (Sweden)

    Roziana Ramli

    2017-01-01

    Full Text Available Retinal image registration is important to assist diagnosis and monitor retinal diseases, such as diabetic retinopathy and glaucoma. However, registering retinal images for various registration applications requires the detection and distribution of feature points on the low-quality region that consists of vessels of varying contrast and sizes. A recent feature detector known as Saddle detects feature points on vessels that are poorly distributed and densely positioned on strong contrast vessels. Therefore, we propose a multiresolution difference of Gaussian pyramid with Saddle detector (D-Saddle to detect feature points on the low-quality region that consists of vessels with varying contrast and sizes. D-Saddle is tested on Fundus Image Registration (FIRE Dataset that consists of 134 retinal image pairs. Experimental results show that D-Saddle successfully registered 43% of retinal image pairs with average registration accuracy of 2.329 pixels while a lower success rate is observed in other four state-of-the-art retinal image registration methods GDB-ICP (28%, Harris-PIIFD (4%, H-M (16%, and Saddle (16%. Furthermore, the registration accuracy of D-Saddle has the weakest correlation (Spearman with the intensity uniformity metric among all methods. Finally, the paired t-test shows that D-Saddle significantly improved the overall registration accuracy of the original Saddle.

  5. Co-registration of the BNCT treatment planning images for clinical practice

    International Nuclear Information System (INIS)

    Salli, Eero; Seppaelae, Tiina; Kankaanranta, Leena; Asikainen, Sami; Savolainen, Sauli; Koivunoro, Hanna

    2006-01-01

    We have co-registered MRI, CT and FBPA-PET images for BNCT in clinical practice. Co-registration improves the spatial accuracy of the treatment planning by enabling use of information from all the co-registered modalities. The multimodal co-registration has been implemented as a service product provided by the Imaging Center of Helsinki University Central Hospital to other departments. To increase the accuracy of co-registration and patient positioning in the head area BNCT, a patient-specific fixation mask suitable for PET, MRI and CT was developed. The goal of the fixation mask is to normalize the orientation of the patient's head and neck. Co-registration is performed at the image processing unit by using a rigid body model, mutual-information based algorithms and partly in-house developed software tools. The accuracy of co-registration is verified by comparing the locations of the external skin markers and anatomical landmarks in different modalities. After co-registration, the images are transformed and covered into a format required by the BNCT dose-planning software and set to the dose-planning unit of the hospital. So far co-registration has been done for 22 patients. The co-registration protocol has proved to be reliable and efficient. Some registration errors are seen on some patients in the neck area because the rigid-body model used in co-registration is not fully valid for the brain-neck entity. The registration accuracy in this area could likely be improved by implementing a co-registration procedure utilizing a partly non-rigid body model. (author)

  6. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    Directory of Open Access Journals (Sweden)

    Maria D. Tukalo

    2013-09-01

    Full Text Available This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions to enhance the creative potential of students in a modern learning environment.

  7. Selection and Evaluation of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Doğan Atılgan

    2013-11-01

    Full Text Available Publication boom and issues related to controlling and accession of printed sources have created some problems after World War II. Consequently, publishing industry has encountered the problem of finding possible solution for emerged situation. Industry of electronic publishing has started to improve with the rapid increase of the price of printed sources as well as the problem of publication boom. The first effects of electronic publishing were appeared on the academic and scholarly publications then electronic publishing became a crucial part of all types of publications. As a result of these developments, collection developments and service policies of information centers were also significantly changed. In this article, after a general introduction about selection and evaluation processes of electronic publications, the subscribed databases by a state and a privately owned university in Turkey and their usage were examined.

  8. Temadag om registrering/katalogisering til Web-katalogen

    DEFF Research Database (Denmark)

    Hansen, Hanne Hørl; Hammershøi, Lene

    2002-01-01

    Referat fra temadag om registrering/katalogisering til Web-katalogen afholdt af DFs Interessekreds for Registrering på RUC d. 13.marts 2002. Oplægsholdere fra Danmark og England gav deres bud på status og udviklingstendenser for arbejdet med at skabe og forbedre web-baserede bibliotekskataloger...

  9. 40 CFR 79.4 - Requirement of registration.

    Science.gov (United States)

    2010-07-01

    ... problem, however, a fuel manufacturer may use an additive that he has not previously reported provided... Section 79.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGISTRATION OF FUELS AND FUEL ADDITIVES General Provisions § 79.4 Requirement of registration. (a) Fuels. (1...

  10. Learning-Based Approaches to Deformable Image Registration

    NARCIS (Netherlands)

    Münzing, SEA

    2014-01-01

    Accurate registration of images is an important and often crucial step in many areas of image processing and analysis, yet it is only used in a small percentage of possible applications. Automated registration methods are not considered to be sufficiently robust to handle complex deformations and

  11. ACIR: automatic cochlea image registration

    Science.gov (United States)

    Al-Dhamari, Ibraheem; Bauer, Sabine; Paulus, Dietrich; Lissek, Friedrich; Jacob, Roland

    2017-02-01

    Efficient Cochlear Implant (CI) surgery requires prior knowledge of the cochlea's size and its characteristics. This information helps to select suitable implants for different patients. To get these measurements, a segmentation method of cochlea medical images is needed. An important pre-processing step for good cochlea segmentation involves efficient image registration. The cochlea's small size and complex structure, in addition to the different resolutions and head positions during imaging, reveals a big challenge for the automated registration of the different image modalities. In this paper, an Automatic Cochlea Image Registration (ACIR) method for multi- modal human cochlea images is proposed. This method is based on using small areas that have clear structures from both input images instead of registering the complete image. It uses the Adaptive Stochastic Gradient Descent Optimizer (ASGD) and Mattes's Mutual Information metric (MMI) to estimate 3D rigid transform parameters. The use of state of the art medical image registration optimizers published over the last two years are studied and compared quantitatively using the standard Dice Similarity Coefficient (DSC). ACIR requires only 4.86 seconds on average to align cochlea images automatically and to put all the modalities in the same spatial locations without human interference. The source code is based on the tool elastix and is provided for free as a 3D Slicer plugin. Another contribution of this work is a proposed public cochlea standard dataset which can be downloaded for free from a public XNAT server.

  12. Simple shape space for 3D face registration

    Science.gov (United States)

    Košir, Andrej; Perkon, Igor; Bracun, Drago; Tasic, Jurij; Mozina, Janez

    2009-09-01

    Three dimensional (3D) face recognition is a topic getting increasing interest in biometric applications. In our research framework we developed a laser scanner that provides 3D cloud information and texture data. In a user scenario with cooperative subjects with indoor light conditions, we address three problems of 3D face biometrics: the face registration, the formulation of a shape space together with a special designed gradient algorithm and the impact of initial approximation to the convergence of a registration algorithm. By defining the face registration as a problem of aligning a 3D data cloud with a predefined reference template, we solve the registration problem with a second order gradient algorithm working on a shape space designed for reducing the computational complexity of the method.

  13. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  14. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  15. 3-D brain image registration using optimal morphological processing

    International Nuclear Information System (INIS)

    Loncaric, S.; Dhawan, A.P.

    1994-01-01

    The three-dimensional (3-D) registration of Magnetic Resonance (MR) and Positron Emission Tomographic (PET) images of the brain is important for analysis of the human brain and its diseases. A procedure for optimization of (3-D) morphological structuring elements, based on a genetic algorithm, is presented in the paper. The registration of the MR and PET images is done by means of a registration procedure in two major phases. In the first phase, the Iterative Principal Axis Transform (IPAR) is used for initial registration. In the second phase, the optimal shape description method based on the Morphological Signature Transform (MST) is used for final registration. The morphological processing is used to improve the accuracy of the basic IPAR method. The brain ventricle is used as a landmark for MST registration. A near-optimal structuring element obtained by means of a genetic algorithm is used in MST to describe the shape of the ventricle. The method has been tested on the set of brain images demonstrating the feasibility of approach. (author). 11 refs., 3 figs

  16. Registration of Vibro-acoustography Images and X-ray Mammography.

    Science.gov (United States)

    Gholam Hosseini, H; Fatemi, M; Alizad, A

    2005-01-01

    Image registration has been widely used for generating more diagnostic and clinical values in medical imaging. On the other hand, inaccurate image registration and incorrect localization of region of interest risks a potential impact on patients. Vibro-acoustography (VA) is a new imaging modality that has been applied to both medical and industrial imaging. Combining unique diagnostic information of VA with other medical imaging is one of our research interests. In this work, we studied the VA and x-ray image pairs and adopted a flexible control-point selection technique for image registration. A modified second-order polynomial, which leads to a scale/rotation/translation invariant registration, was used. The results of registration were used to spatially transform the breast VA images to map with the x-ray mammography with a registration error of less than 1.65 mm. These two completely different modalities were combined to generate an image including a ratio of each image pixel value. Therefore, the proposed technique allows clinicians to maximize their insight by combining the information from x-ray mammogram and VA modalities into a single image.

  17. Clinical trial registration in physical therapy journals: a cross-sectional study.

    Science.gov (United States)

    Babu, Abraham Samuel; Veluswamy, Sundar Kumar; Rao, Pratiksha Tilak; Maiya, Arun G

    2014-01-01

    Clinical trial registration has become an important part of editorial policies of various biomedical journals, including a few physical therapy journals. However, the extent to which editorial boards enforce the need for trial registration varies across journals. The purpose of this study was to identify editorial policies and reporting of trial registration details in MEDLINE-indexed English-language physical therapy journals. This study was carried out using a cross-sectional design. Editorial policies on trial registration of MEDLINE-indexed member journals of the International Society of Physiotherapy Journal Editors (ISPJE) (Journal of Geriatric Physical Therapy, Journal of Hand Therapy, Journal of Neurologic Physical Therapy, Journal of Orthopaedic and Sports Physical Therapy, Journal of Physiotherapy [formerly Australian Journal of Physiotherapy], Journal of Science and Medicine in Sport, Manual Therapy, Physical Therapy, Physical Therapy in Sport, Physiotherapy, Physiotherapy Research International, Physiotherapy Theory and Practice, and Revista Brasileira de Fisioterapia) were reviewed in April 2013. Full texts of reports of clinical trials published in these journals between January 1, 2008, and December 31, 2012, were independently assessed for information on trial registration. Among the 13 journals, 8 recommended trial registration, and 6 emphasized prospective trial registration. As of April 2013, 4,618 articles were published between January 2008 and December 2012, of which 9% (417) were clinical trials and 29% (121/417) of these reported trial registration details. A positive trend in reporting of trial registration was observed from 2008 to 2012. The study was limited to MEDLINE-indexed ISPJE member journals. Editorial policies on trial registration of physical therapy journals and a rising trend toward reporting of trial registration details indicate a positive momentum toward trial registration. Physical therapy journal editors need to show

  18. 21 CFR 607.26 - Amendments to establishment registration.

    Science.gov (United States)

    2010-04-01

    ... registration. Changes in individual ownership, corporate or partnership structure, location, or blood-product...) as an amendment to registration within 5 days of such changes. Changes in the names of officers and...

  19. 77 FR 1777 - 60-Day Notice of Proposed Information Collection: DS-260, Electronic Application for Immigration...

    Science.gov (United States)

    2012-01-11

    ... DEPARTMENT OF STATE [Public Notice: 7750] 60-Day Notice of Proposed Information Collection: DS-260, Electronic Application for Immigration Visa and Alien Registration, 1405-0185 ACTION: Notice of request for... for Immigration Visa and Alien Registration. OMB Control Number: 1405-0185. Type of Request: Extension...

  20. The level of the usage of the human resource information system and electronic recruitment in Croatian companies

    Directory of Open Access Journals (Sweden)

    Snježana Pivac

    2014-12-01

    Full Text Available Performing business according to contemporary requirements influences companies for continuous usage of modern managerial tools, such as a human resource information system (HRIS and electronic recruitment (ER. Human resources have been recognised as curtail resources and the main source of a competitive advantage in creation of successful business performance. In order to attract and select the top employees, companies use quality information software for attracting internal ones, and electronic recruitment for attracting the best possible external candidates. The main aim of this paper is to research the level of the usage of HRIS and ER within medium-size and large Croatian companies. Moreover, the additional aim of this paper is to evaluate the relationship among the usage of these modern managerial tools and the overall success of human resource management within these companies. For the purpose of this paper, primary and secondary research has been conducted in order to reveal the level of the usage of HRIS and ER as well as the overall success of human resource management in Croatian companies. The companies’ classification (HRIS and ER is done by using the non-hierarchical k-means cluster method as well as the nonparametric Kruskal Wallis test. Further, the companies are ranked by the multicriteria PROMETHEE method. Relevant nonparametric tests are used for testing the overall companies’ HRM. Finally, binary logistic regression is estimated, relating binary variable HRM and HRIS development. After detailed research, it can be concluded that large Croatian companies apply HRIS in majority (with a positive relation to HRM performance, but still require certain degrees of its development.

  1. The electronic encapsulation of knowledge in hydraulics, hydrology and water resources

    Science.gov (United States)

    Abbott, Michael B.

    The rapidly developing practice of encapsulating knowledge in electronic media is shown to lead necessarily to the restructuring of the knowledge itself. The consequences of this for hydraulics, hydrology and more general water-resources management are investigated in particular relation to current process-simulation, real-time control and advice-serving systems. The generic properties of the electronic knowledge encapsulator are described, and attention is drawn to the manner in which knowledge 'goes into hiding' through encapsulation. This property is traced in the simple situations of pure mathesis and in the more complex situations of taxinomia using one example each from hydraulics and hydrology. The consequences for systems architectures are explained, pointing to the need for multi-agent architectures for ecological modelling and for more general hydroinformatics systems also. The relevance of these developments is indicated by reference to ongoing projects in which they are currently being realised. In conclusion, some more general epistemological aspects are considered within the same context. As this contribution is so much concerned with the processes of signification and communication, it has been partly shaped by the theory of semiotics, as popularised by Eco ( A Theory of Semiotics, Indiana University, Bloomington, 1977).

  2. 15 CFR 296.7 - Joint venture registration.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Joint venture registration. 296.7 Section 296.7 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade NATIONAL... PROGRAM General § 296.7 Joint venture registration. Joint ventures selected for assistance under the...

  3. Multimodality image registration with software: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    Slomka, Piotr J. [Cedars-Sinai Medical Center, AIM Program/Department of Imaging, Los Angeles, CA (United States); University of California, David Geffen School of Medicine, Los Angeles, CA (United States); Baum, Richard P. [Center for PET, Department of Nuclear Medicine, Bad Berka (Germany)

    2009-03-15

    Multimodality image integration of functional and anatomical data can be performed by means of dedicated hybrid imaging systems or by software image co-registration techniques. Hybrid positron emission tomography (PET)/computed tomography (CT) systems have found wide acceptance in oncological imaging, while software registration techniques have a significant role in patient-specific, cost-effective, and radiation dose-effective application of integrated imaging. Software techniques allow accurate (2-3 mm) rigid image registration of brain PET with CT and MRI. Nonlinear techniques are used in whole-body image registration, and recent developments allow for significantly accelerated computing times. Nonlinear software registration of PET with CT or MRI is required for multimodality radiation planning. Difficulties remain in the validation of nonlinear registration of soft tissue organs. The utilization of software-based multimodality image integration in a clinical environment is sometimes hindered by the lack of appropriate picture archiving and communication systems (PACS) infrastructure needed to efficiently and automatically integrate all available images into one common database. In cardiology applications, multimodality PET/single photon emission computed tomography and coronary CT angiography imaging is typically not required unless the results of one of the tests are equivocal. Software image registration is likely to be used in a complementary fashion with hybrid PET/CT or PET/magnetic resonance imaging systems. Software registration of stand-alone scans ''paved the way'' for the clinical application of hybrid scanners, demonstrating practical benefits of image integration before the hybrid dual-modality devices were available. (orig.)

  4. Population based ranking of frameless CT-MRI registration methods

    Energy Technology Data Exchange (ETDEWEB)

    Opposits, Gabor; Kis, Sandor A.; Tron, Lajos; Emri, Miklos [Debrecen Univ. (Hungary). Dept. of Nuclear Medicine; Berenyi, Ervin [Debrecen Univ. (Hungary). Dept. of Biomedical Laboratory and Imaging Science; Takacs, Endre [Rotating Gamma Ltd., Debrecen (Hungary); Dobai, Jozsef G.; Bognar, Laszlo [Debrecen Univ., Medical Center (Hungary). Dept. of Neurosurgery; Szuecs, Bernadett [ScanoMed Ltd., Debrecen (Hungary)

    2015-07-01

    Clinical practice often requires simultaneous information obtained by two different imaging modalities. Registration algorithms are commonly used for this purpose. Automated procedures are very helpful in cases when the same kind of registration has to be performed on images of a high number of subjects. Radiotherapists would prefer to use the best automated method to assist therapy planning, however there are not accepted procedures for ranking the different registration algorithms. We were interested in developing a method to measure the population level performance of CT-MRI registration algorithms by a parameter of values in the [0,1] interval. Pairs of CT and MRI images were collected from 1051 subjects. Results of an automated registration were corrected manually until a radiologist and a neurosurgeon expert both accepted the result as good. This way 1051 registered MRI images were produced by the same pair of experts to be used as gold standards for the evaluation of the performance of other registration algorithms. Pearson correlation coefficient, mutual information, normalized mutual information, Kullback-Leibler divergence, L{sub 1} norm and square L{sub 2} norm (dis)similarity measures were tested for sensitivity to indicate the extent of (dis)similarity of a pair of individual mismatched images. The square Hellinger distance proved suitable to grade the performance of registration algorithms at population level providing the developers with a valuable tool to rank algorithms. The developed procedure provides an objective method to find the registration algorithm performing the best on the population level out of newly constructed or available preselected ones.

  5. Laser interrogation of latent vehicle registration number

    Energy Technology Data Exchange (ETDEWEB)

    Russo, R.E. [Lawrence Berkeley Lab., CA (United States). Energy and Environment Div.]|[Lawrence Livermore National Lab., CA (United States). Forensic Science Center; Pelkey, G.E. [City of Livermore Police Dept., CA (United States); Grant, P.; Whipple, R.E.; Andresen, B.D. [Lawrence Livermore National Lab., CA (United States). Forensic Science Center

    1994-09-01

    A recent investigation involved automobile registration numbers as important evidentiary specimens. In California, as in most states, small, thin metallic decals are issued to owners of vehicles each year as the registration is renewed. The decals are applied directly to the license plate of the vehicle and typically on top of the previous year`s expired decal. To afford some degree of security, the individual registration decals have been designed to tear easily; they cannot be separated from each other, but can be carefully removed intact from the metal license plate by using a razor blade. In September 1993, the City of Livermore Police Department obtained a blue 1993 California decal that had been placed over an orange 1992 decal. The two decals were being investigated as possible evidence in a case involving vehicle registration fraud. To confirm the suspicion and implicate a suspect, the department needed to known the registration number on the bottom (completely covered) 1992 decal. The authors attempted to use intense and directed light to interrogate the colored stickers. Optical illumination using a filtered white-light source partially identified the latent number. However, the most successful technique used a tunable dye laser pumped by a pulsed Nd:YAG laser. By selectively tuning the wavelength and intensity of the dye laser, backlit illumination of the decals permitted visualization of the underlying registration number through the surface of the top sticker. With optimally-tuned wavelength and intensity, 100% accuracy was obtained in identifying the sequence of latent characters. The advantage of optical techniques is their completely nondestructive nature, thus preserving the evidence for further interrogation or courtroom presentation.

  6. Pesticide Registration Information System

    Data.gov (United States)

    U.S. Environmental Protection Agency — PRISM provides an integrated, web portal for all pesticide related data, communications, registrations and transactions for OPP and its stakeholders, partners and...

  7. A Novel Technique for Prealignment in Multimodality Medical Image Registration

    Directory of Open Access Journals (Sweden)

    Wu Zhou

    2014-01-01

    Full Text Available Image pair is often aligned initially based on a rigid or affine transformation before a deformable registration method is applied in medical image registration. Inappropriate initial registration may compromise the registration speed or impede the convergence of the optimization algorithm. In this work, a novel technique was proposed for prealignment in both monomodality and multimodality image registration based on statistical correlation of gradient information. A simple and robust algorithm was proposed to determine the rotational differences between two images based on orientation histogram matching accumulated from local orientation of each pixel without any feature extraction. Experimental results showed that it was effective to acquire the orientation angle between two unregistered images with advantages over the existed method based on edge-map in multimodalities. Applying the orientation detection into the registration of CT/MR, T1/T2 MRI, and monomadality images with respect to rigid and nonrigid deformation improved the chances of finding the global optimization of the registration and reduced the search space of optimization.

  8. RESEARCH OF INFLUENCE OF QUALITY OF ELECTRONIC EDUCATIONAL RESOURCES ON QUALITY OF TRAINING WITH USE OF DISTANCE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    H. M. Kravtsov

    2013-03-01

    Full Text Available Communication improving of educational processes requires today new approaches to the management arrangements and forming of educational policy in the field of distance learning, which is based on the use of modern information and communication technologies. An important step in this process is the continuous monitoring of the development and implementation of information technology and, in particular, the distance learning systems in higher educational establishments. The main objective of the monitoring is the impact assessment on the development of distance learning following the state educational standards, curricula, methodical and technical equipment and other factors; factors revelation that influence the implementation and outcomes of distance learning; results comparison of educational institution functioning and distance education systems in order to determine the most efficient ways of its development. The paper presents the analysis results of the dependence of the quality of educational services on the electronic educational resources. Trends in educational services development was studied by comparing the quality influence of electronic educational resources on the quality of educational services of higher pedagogical educational institutions of Ukraine as of 2009-2010 and 2012-2013. Generally, the analysis of the survey results allows evaluating quality of the modern education services as satisfactory and it can be said that almost 70% of the success of their future development depends on the quality of the used electronic educational resources and distance learning systems in particular.

  9. Interactive initialization of 2D/3D rigid registration

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Ren Hui; Güler, Özgür [The Sheikh Zayed Institute for Pediatric Surgical Innovation, Children' s National Medical Center, Washington, DC 20010 (United States); Kürklüoglu, Mustafa [Department of Cardiac Surgery, Children' s National Medical Center, Washington, DC 20010 (United States); Lovejoy, John [Department of Orthopaedic Surgery and Sports Medicine, Children' s National Medical Center, Washington, DC 20010 (United States); Yaniv, Ziv, E-mail: ZYaniv@childrensnational.org [The Sheikh Zayed Institute for Pediatric Surgical Innovation, Children' s National Medical Center, Washington, DC 20010 and Departments of Pediatrics and Radiology, George Washington University, Washington, DC 20037 (United States)

    2013-12-15

    Purpose: Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. Methods: The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. Results: In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. Conclusions: Based on

  10. Interactive initialization of 2D/3D rigid registration

    International Nuclear Information System (INIS)

    Gong, Ren Hui; Güler, Özgür; Kürklüoglu, Mustafa; Lovejoy, John; Yaniv, Ziv

    2013-01-01

    Purpose: Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. Methods: The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. Results: In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. Conclusions: Based on the

  11. Tracking the Flow of Resources in Electronic Waste - The Case of End-of-Life Computer Hard Disk Drives.

    Science.gov (United States)

    Habib, Komal; Parajuly, Keshav; Wenzel, Henrik

    2015-10-20

    Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.

  12. JALFHCC - Patient Registration Service

    Data.gov (United States)

    Department of Veterans Affairs — The Captain James A. Lovell Federal Health Care Center (JALFHCC) Patient Registration Service supports the operation of the first VA/Navy Federal Health Care Center...

  13. CT image registration in sinogram space.

    Science.gov (United States)

    Mao, Weihua; Li, Tianfang; Wink, Nicole; Xing, Lei

    2007-09-01

    Object displacement in a CT scan is generally reflected in CT projection data or sinogram. In this work, the direct relationship between object motion and the change of CT projection data (sinogram) is investigated and this knowledge is applied to create a novel algorithm for sinogram registration. Calculated and experimental results demonstrate that the registration technique works well for registering rigid 2D or 3D motion in parallel and fan beam samplings. Problem and solution for 3D sinogram-based registration of metallic fiducials are also addressed. Since the motion is registered before image reconstruction, the presented algorithm is particularly useful when registering images with metal or truncation artifacts. In addition, this algorithm is valuable for dealing with situations where only limited projection data are available, making it appealing for various applications in image guided radiation therapy.

  14. CT image registration in sinogram space

    International Nuclear Information System (INIS)

    Mao Weihua; Li Tianfang; Wink, Nicole; Xing Lei

    2007-01-01

    Object displacement in a CT scan is generally reflected in CT projection data or sinogram. In this work, the direct relationship between object motion and the change of CT projection data (sinogram) is investigated and this knowledge is applied to create a novel algorithm for sinogram registration. Calculated and experimental results demonstrate that the registration technique works well for registering rigid 2D or 3D motion in parallel and fan beam samplings. Problem and solution for 3D sinogram-based registration of metallic fiducials are also addressed. Since the motion is registered before image reconstruction, the presented algorithm is particularly useful when registering images with metal or truncation artifacts. In addition, this algorithm is valuable for dealing with situations where only limited projection data are available, making it appealing for various applications in image guided radiation therapy

  15. Automatic registration of terrestrial point cloud using panoramic reflectance images

    NARCIS (Netherlands)

    Kang, Z.

    2008-01-01

    Much attention is paid to registration of terrestrial point clouds nowadays. Research is carried out towards improved efficiency and automation of the registration process. This paper reports a new approach for point clouds registration utilizing reflectance panoramic images. The approach follows a

  16. Locally orderless registration

    DEFF Research Database (Denmark)

    Darkner, Sune; Sporring, Jon

    2013-01-01

    This paper presents a unifying approach for calculating a wide range of popular, but seemingly very different, similarity measures. Our domain is the registration of n-dimensional images sampled on a regular grid, and our approach is well suited for gradient-based optimization algorithms. Our app...

  17. Biomedical Image Registration

    DEFF Research Database (Denmark)

    This book constitutes the refereed proceedings of the 8th International Workshop on Biomedical Image Registration, WBIR 2018, held in Leiden, The Netherlands, in June 2018. The 11 full and poster papers included in this volume were carefully reviewed and selected from 17 submitted papers. The pap...

  18. 4D ultrasound and 3D MRI registration of beating heart

    International Nuclear Information System (INIS)

    Herlambang, N.; Matsumiya, K.; Masamune, K.; Dohi, T.; Liao, H.; Tsukihara, H.; Takamoto, S.

    2007-01-01

    To realize intra-cardiac surgery without cardio-pulmonary bypass, a medical imaging technique with both high image quality and data acquisition rate that is fast enough to follow heart beat movements is required. In this research, we proposed a method that utilized the image quality of MRI and the speed of ultrasound. We developed a 4D image reconstruction method using image registration of 3D MRI and 4D ultrasound images. The registration method consists of rigid registration between 3D MRI and 3D ultrasound with the same heart beat phase, and non-rigid registration between 3D ultrasound images from different heart beat phases. Non-rigid registration was performed with B-spline based registration using variable spring model. In phantom experiment using balloon phantom, registration accuracy was less than 2 mm for total heart volume variation range of 10%. We applied our registration method on 3D MRI and 4D ultrasound images of a volunteer's beating heart data and confirmed through visual observation that heart beat pattern was well reproduced. (orig.)

  19. Robust linear registration of CT images using random regression forests

    Science.gov (United States)

    Konukoglu, Ender; Criminisi, Antonio; Pathak, Sayan; Robertson, Duncan; White, Steve; Haynor, David; Siddiqui, Khan

    2011-03-01

    Global linear registration is a necessary first step for many different tasks in medical image analysis. Comparing longitudinal studies1, cross-modality fusion2, and many other applications depend heavily on the success of the automatic registration. The robustness and efficiency of this step is crucial as it affects all subsequent operations. Most common techniques cast the linear registration problem as the minimization of a global energy function based on the image intensities. Although these algorithms have proved useful, their robustness in fully automated scenarios is still an open question. In fact, the optimization step often gets caught in local minima yielding unsatisfactory results. Recent algorithms constrain the space of registration parameters by exploiting implicit or explicit organ segmentations, thus increasing robustness4,5. In this work we propose a novel robust algorithm for automatic global linear image registration. Our method uses random regression forests to estimate posterior probability distributions for the locations of anatomical structures - represented as axis aligned bounding boxes6. These posterior distributions are later integrated in a global linear registration algorithm. The biggest advantage of our algorithm is that it does not require pre-defined segmentations or regions. Yet it yields robust registration results. We compare the robustness of our algorithm with that of the state of the art Elastix toolbox7. Validation is performed via 1464 pair-wise registrations in a database of very diverse 3D CT images. We show that our method decreases the "failure" rate of the global linear registration from 12.5% (Elastix) to only 1.9%.

  20. [Multimodal medical image registration using cubic spline interpolation method].

    Science.gov (United States)

    He, Yuanlie; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2007-12-01

    Based on the characteristic of the PET-CT multimodal image series, a novel image registration and fusion method is proposed, in which the cubic spline interpolation method is applied to realize the interpolation of PET-CT image series, then registration is carried out by using mutual information algorithm and finally the improved principal component analysis method is used for the fusion of PET-CT multimodal images to enhance the visual effect of PET image, thus satisfied registration and fusion results are obtained. The cubic spline interpolation method is used for reconstruction to restore the missed information between image slices, which can compensate for the shortage of previous registration methods, improve the accuracy of the registration, and make the fused multimodal images more similar to the real image. Finally, the cubic spline interpolation method has been successfully applied in developing 3D-CRT (3D Conformal Radiation Therapy) system.

  1. Performance evaluation of grid-enabled registration algorithms using bronze-standards

    CERN Document Server

    Glatard, T; Montagnat, J

    2006-01-01

    Evaluating registration algorithms is difficult due to the lack of gold standard in most clinical procedures. The bronze standard is a real-data based statistical method providing an alternative registration reference through a computationally intensive image database registration procedure. We propose in this paper an efficient implementation of this method through a grid-interfaced workflow enactor enabling the concurrent processing of hundreds of image registrations in a couple of hours only. The performances of two different grid infrastructures were compared. We computed the accuracy of 4 different rigid registration algorithms on longitudinal MRI images of brain tumors. Results showed an average subvoxel accuracy of 0.4 mm and 0.15 degrees in rotation.

  2. Consistency of parametric registration in serial MRI studies of brain tumor progression

    International Nuclear Information System (INIS)

    Mang, Andreas; Buzug, Thorsten M.; Schnabel, Julia A.; Crum, William R.; Modat, Marc; Ourselin, Sebastien; Hawkes, David J.; Camara-Rey, Oscar; Palm, Christoph; Caseiras, Gisele Brasil; Jaeger, H.R.

    2008-01-01

    The consistency of parametric registration in multi-temporal magnetic resonance (MR) imaging studies was evaluated. Serial MRI scans of adult patients with a brain tumor (glioma) were aligned by parametric registration. The performance of low-order spatial alignment (6/9/12 degrees of freedom) of different 3D serial MR-weighted images is evaluated. A registration protocol for the alignment of all images to one reference coordinate system at baseline is presented. Registration results were evaluated for both, multimodal intra-timepoint and mono-modal multi-temporal registration. The latter case might present a challenge to automatic intensity-based registration algorithms due to ill-defined correspondences. The performance of our algorithm was assessed by testing the inverse registration consistency. Four different similarity measures were evaluated to assess consistency. Careful visual inspection suggests that images are well aligned, but their consistency may be imperfect. Sub-voxel inconsistency within the brain was found for allsimilarity measures used for parametric multi-temporal registration. T1-weighted images were most reliable for establishing spatial correspondence between different timepoints. The parametric registration algorithm is feasible for use in this application. The sub-voxel resolution mean displacement error of registration transformations demonstrates that the algorithm converges to an almost identical solution for forward and reverse registration. (orig.)

  3. Accelerating Neuroimage Registration through Parallel Computation of Similarity Metric.

    Directory of Open Access Journals (Sweden)

    Yun-Gang Luo

    Full Text Available Neuroimage registration is crucial for brain morphometric analysis and treatment efficacy evaluation. However, existing advanced registration algorithms such as FLIRT and ANTs are not efficient enough for clinical use. In this paper, a GPU implementation of FLIRT with the correlation ratio (CR as the similarity metric and a GPU accelerated correlation coefficient (CC calculation for the symmetric diffeomorphic registration of ANTs have been developed. The comparison with their corresponding original tools shows that our accelerated algorithms can greatly outperform the original algorithm in terms of computational efficiency. This paper demonstrates the great potential of applying these registration tools in clinical applications.

  4. 75 FR 52737 - Pesticide Product Registrations; Unconditional and Conditional Approvals

    Science.gov (United States)

    2010-08-27

    ...: Plasma Neem Oil Biological insecticide, EPA Registration Number 84185-4 for use on several food and non...) of the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), of registrations for pesticide... the end of the relevant registration approval summary using the instructions provided under FOR...

  5. Evaluation of whole-body MR to CT deformable image registration

    NARCIS (Netherlands)

    Akbarzadeh, A.; Gutierrez, D.; Baskin, A.; Ay, M. R.; Ahmadian, A.; Alam, N. Riahi; Loevblad, K. O.; Zaidi, H.

    2013-01-01

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based

  6. Expert Talks: Understanding civil registration and vital statistics ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2017-09-13

    Sep 13, 2017 ... What are CRVS systems and why do they matter? ... Cambodia cleared civil registration backlogs by providing free, time-bound registration. ... IDRC supports results-based research that has real impacts on the ground and ...

  7. Serial volumetric registration of pulmonary CT studies

    Science.gov (United States)

    Silva, José Silvestre; Silva, Augusto; Sousa Santos, Beatriz

    2008-03-01

    Detailed morphological analysis of pulmonary structures and tissue, provided by modern CT scanners, is of utmost importance as in the case of oncological applications both for diagnosis, treatment, and follow-up. In this case, a patient may go through several tomographic studies throughout a period of time originating volumetric sets of image data that must be appropriately registered in order to track suspicious radiological findings. The structures or regions of interest may change their position or shape in CT exams acquired at different moments, due to postural, physiologic or pathologic changes, so, the exams should be registered before any follow-up information can be extracted. Postural mismatching throughout time is practically impossible to avoid being particularly evident when imaging is performed at the limiting spatial resolution. In this paper, we propose a method for intra-patient registration of pulmonary CT studies, to assist in the management of the oncological pathology. Our method takes advantage of prior segmentation work. In the first step, the pulmonary segmentation is performed where trachea and main bronchi are identified. Then, the registration method proceeds with a longitudinal alignment based on morphological features of the lungs, such as the position of the carina, the pulmonary areas, the centers of mass and the pulmonary trans-axial principal axis. The final step corresponds to the trans-axial registration of the corresponding pulmonary masked regions. This is accomplished by a pairwise sectional registration process driven by an iterative search of the affine transformation parameters leading to optimal similarity metrics. Results with several cases of intra-patient, intra-modality registration, up to 7 time points, show that this method provides accurate registration which is needed for quantitative tracking of lesions and the development of image fusion strategies that may effectively assist the follow-up process.

  8. Groupwise registration of MR brain images with tumors

    Science.gov (United States)

    Tang, Zhenyu; Wu, Yihong; Fan, Yong

    2017-09-01

    A novel groupwise image registration framework is developed for registering MR brain images with tumors. Our method iteratively estimates a normal-appearance counterpart for each tumor image to be registered and constructs a directed graph (digraph) of normal-appearance images to guide the groupwise image registration. Particularly, our method maps each tumor image to its normal appearance counterpart by identifying and inpainting brain tumor regions with intensity information estimated using a low-rank plus sparse matrix decomposition based image representation technique. The estimated normal-appearance images are groupwisely registered to a group center image guided by a digraph of images so that the total length of ‘image registration paths’ to be the minimum, and then the original tumor images are warped to the group center image using the resulting deformation fields. We have evaluated our method based on both simulated and real MR brain tumor images. The registration results were evaluated with overlap measures of corresponding brain regions and average entropy of image intensity information, and Wilcoxon signed rank tests were adopted to compare different methods with respect to their regional overlap measures. Compared with a groupwise image registration method that is applied to normal-appearance images estimated using the traditional low-rank plus sparse matrix decomposition based image inpainting, our method achieved higher image registration accuracy with statistical significance (p  =  7.02  ×  10-9).

  9. Fast free-form deformable registration via calculus of variations

    International Nuclear Information System (INIS)

    Lu Weiguo; Chen Mingli; Olivera, Gustavo H; Ruchala, Kenneth J; Mackie, Thomas R

    2004-01-01

    In this paper, we present a fully automatic, fast and accurate deformable registration technique. This technique deals with free-form deformation. It minimizes an energy functional that combines both similarity and smoothness measures. By using calculus of variations, the minimization problem was represented as a set of nonlinear elliptic partial differential equations (PDEs). A Gauss-Seidel finite difference scheme is used to iteratively solve the PDE. The registration is refined by a multi-resolution approach. The whole process is fully automatic. It takes less than 3 min to register two three-dimensional (3D) image sets of size 256 x 256 x 61 using a single 933 MHz personal computer. Extensive experiments are presented. These experiments include simulations, phantom studies and clinical image studies. Experimental results show that our model and algorithm are suited for registration of temporal images of a deformable body. The registration of inspiration and expiration phases of the lung images shows that the method is able to deal with large deformations. When applied to the daily CT images of a prostate patient, the results show that registration based on iterative refinement of displacement field is appropriate to describe the local deformations in the prostate and the rectum. Similarity measures improved significantly after the registration. The target application of this paper is for radiotherapy treatment planning and evaluation that incorporates internal organ deformation throughout the course of radiation therapy. The registration method could also be equally applied in diagnostic radiology

  10. Feasibility of Multimodal Deformable Registration for Head and Neck Tumor Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Fortunati, Valerio, E-mail: v.fortunati@erasmusmc.nl [Biomedical Imaging Group Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC University Medical Center, Rotterdam (Netherlands); Verhaart, René F. [Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC University Medical Center Cancer Institute, Rotterdam (Netherlands); Angeloni, Francesco [Istituto di Ricovero e Cura a Carattere Scientifico Foundation SDN for Research and High Education in Nuclear Diagnostics, Naples (Italy); Lugt, Aad van der [Department of Radiology, Erasmus MC University Medical Center, Rotterdam (Netherlands); Niessen, Wiro J. [Biomedical Imaging Group Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC University Medical Center, Rotterdam (Netherlands); Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands); Veenland, Jifke F. [Biomedical Imaging Group Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC University Medical Center, Rotterdam (Netherlands); Paulides, Margarethus M. [Hyperthermia Unit, Department of Radiation Oncology, Erasmus MC University Medical Center Cancer Institute, Rotterdam (Netherlands); Walsum, Theo van [Biomedical Imaging Group Rotterdam, Department of Medical Informatics and Radiology, Erasmus MC University Medical Center, Rotterdam (Netherlands)

    2014-09-01

    Purpose: To investigate the feasibility of using deformable registration in clinical practice to fuse MR and CT images of the head and neck for treatment planning. Method and Materials: A state-of-the-art deformable registration algorithm was optimized, evaluated, and compared with rigid registration. The evaluation was based on manually annotated anatomic landmarks and regions of interest in both modalities. We also developed a multiparametric registration approach, which simultaneously aligns T1- and T2-weighted MR sequences to CT. This was evaluated and compared with single-parametric approaches. Results: Our results show that deformable registration yielded a better accuracy than rigid registration, without introducing unrealistic deformations. For deformable registration, an average landmark alignment of approximatively 1.7 mm was obtained. For all the regions of interest excluding the cerebellum and the parotids, deformable registration provided a median modified Hausdorff distance of approximatively 1 mm. Similar accuracies were obtained for the single-parameter and multiparameter approaches. Conclusions: This study demonstrates that deformable registration of head-and-neck CT and MR images is feasible, with overall a significanlty higher accuracy than for rigid registration.

  11. Feasibility of Multimodal Deformable Registration for Head and Neck Tumor Treatment Planning

    International Nuclear Information System (INIS)

    Fortunati, Valerio; Verhaart, René F.; Angeloni, Francesco; Lugt, Aad van der; Niessen, Wiro J.; Veenland, Jifke F.; Paulides, Margarethus M.; Walsum, Theo van

    2014-01-01

    Purpose: To investigate the feasibility of using deformable registration in clinical practice to fuse MR and CT images of the head and neck for treatment planning. Method and Materials: A state-of-the-art deformable registration algorithm was optimized, evaluated, and compared with rigid registration. The evaluation was based on manually annotated anatomic landmarks and regions of interest in both modalities. We also developed a multiparametric registration approach, which simultaneously aligns T1- and T2-weighted MR sequences to CT. This was evaluated and compared with single-parametric approaches. Results: Our results show that deformable registration yielded a better accuracy than rigid registration, without introducing unrealistic deformations. For deformable registration, an average landmark alignment of approximatively 1.7 mm was obtained. For all the regions of interest excluding the cerebellum and the parotids, deformable registration provided a median modified Hausdorff distance of approximatively 1 mm. Similar accuracies were obtained for the single-parameter and multiparameter approaches. Conclusions: This study demonstrates that deformable registration of head-and-neck CT and MR images is feasible, with overall a significanlty higher accuracy than for rigid registration

  12. System for Earth Sample Registration SESAR: Services for IGSN Registration and Sample Metadata Management

    Science.gov (United States)

    Chan, S.; Lehnert, K. A.; Coleman, R. J.

    2011-12-01

    SESAR, the System for Earth Sample Registration, is an online registry for physical samples collected for Earth and environmental studies. SESAR generates and administers the International Geo Sample Number IGSN, a unique identifier for samples that is dramatically advancing interoperability amongst information systems for sample-based data. SESAR was developed to provide the complete range of registry services, including definition of IGSN syntax and metadata profiles, registration and validation of name spaces requested by users, tools for users to submit and manage sample metadata, validation of submitted metadata, generation and validation of the unique identifiers, archiving of sample metadata, and public or private access to the sample metadata catalog. With the development of SESAR v3, we placed particular emphasis on creating enhanced tools that make metadata submission easier and more efficient for users, and that provide superior functionality for users to manage metadata of their samples in their private workspace MySESAR. For example, SESAR v3 includes a module where users can generate custom spreadsheet templates to enter metadata for their samples, then upload these templates online for sample registration. Once the content of the template is uploaded, it is displayed online in an editable grid format. Validation rules are executed in real-time on the grid data to ensure data integrity. Other new features of SESAR v3 include the capability to transfer ownership of samples to other SESAR users, the ability to upload and store images and other files in a sample metadata profile, and the tracking of changes to sample metadata profiles. In the next version of SESAR (v3.5), we will further improve the discovery, sharing, registration of samples. For example, we are developing a more comprehensive suite of web services that will allow discovery and registration access to SESAR from external systems. Both batch and individual registrations will be possible

  13. Registration of 3D Face Scans with Average Face Models

    NARCIS (Netherlands)

    A.A. Salah (Albert Ali); N. Alyuz; L. Akarun

    2008-01-01

    htmlabstractThe accuracy of a 3D face recognition system depends on a correct registration that aligns the facial surfaces and makes a comparison possible. The best results obtained so far use a costly one-to-all registration approach, which requires the registration of each facial surface to all

  14. Pydpiper: A Flexible Toolkit for Constructing Novel Registration Pipelines

    Directory of Open Access Journals (Sweden)

    Miriam eFriedel

    2014-07-01

    Full Text Available Using neuroimaging technologies to elucidate the relationship between genotype and phenotype and brain and behavior will be a key contribution to biomedical research in the twenty-first century. Among the many methods for analyzing neuroimaging data, image registration deserves particular attention due to its wide range of applications. Finding strategies to register together many images and analyze the differences between them can be a challenge, particularly given that different experimental designs require different registration strategies. Moreover, writing software that can handle different types of image registration pipelines in a flexible, reusable and extensible way can be challenging. In response to this challenge, we have created Pydpiper, a neuroimaging registration toolkit written in Python. Pydpiper is an open-source, freely available pipeline framework that provides multiple modules for various image registration applications. Pydpiper offers five key innovations. Specifically: (1 a robust file handling class that allows access to outputs from all stages of registration at any point in the pipeline; (2 the ability of the framework to eliminate duplicate stages; (3 reusable, easy to subclass modules; (4 a development toolkit written for non-developers; (5 four complete applications that run complex image registration pipelines ``out-of-the-box.'' In this paper, we will discuss both the general Pydpiper framework and the various ways in which component modules can be pieced together to easily create new registration pipelines. This will include a discussion of the core principles motivating code development and a comparison of Pydpiper with other available toolkits. We also provide a comprehensive, line-by-line example to orient users with limited programming knowledge and highlight some of the most useful features of Pydpiper. In addition, we will present the four current applications of the code.

  15. Pydpiper: a flexible toolkit for constructing novel registration pipelines.

    Science.gov (United States)

    Friedel, Miriam; van Eede, Matthijs C; Pipitone, Jon; Chakravarty, M Mallar; Lerch, Jason P

    2014-01-01

    Using neuroimaging technologies to elucidate the relationship between genotype and phenotype and brain and behavior will be a key contribution to biomedical research in the twenty-first century. Among the many methods for analyzing neuroimaging data, image registration deserves particular attention due to its wide range of applications. Finding strategies to register together many images and analyze the differences between them can be a challenge, particularly given that different experimental designs require different registration strategies. Moreover, writing software that can handle different types of image registration pipelines in a flexible, reusable and extensible way can be challenging. In response to this challenge, we have created Pydpiper, a neuroimaging registration toolkit written in Python. Pydpiper is an open-source, freely available software package that provides multiple modules for various image registration applications. Pydpiper offers five key innovations. Specifically: (1) a robust file handling class that allows access to outputs from all stages of registration at any point in the pipeline; (2) the ability of the framework to eliminate duplicate stages; (3) reusable, easy to subclass modules; (4) a development toolkit written for non-developers; (5) four complete applications that run complex image registration pipelines "out-of-the-box." In this paper, we will discuss both the general Pydpiper framework and the various ways in which component modules can be pieced together to easily create new registration pipelines. This will include a discussion of the core principles motivating code development and a comparison of Pydpiper with other available toolkits. We also provide a comprehensive, line-by-line example to orient users with limited programming knowledge and highlight some of the most useful features of Pydpiper. In addition, we will present the four current applications of the code.

  16. 75 FR 65293 - Draft Guidelines on Pharmacovigilance of Veterinary Medicinal Products: Electronic Standards for...

    Science.gov (United States)

    2010-10-22

    ...] Draft Guidelines on Pharmacovigilance of Veterinary Medicinal Products: Electronic Standards for... Requirements for the Registration of Veterinary Medicinal Products (VICH) has developed a draft guideline titled ``Pharmacovigilance of Veterinary Medicinal Products: Electronic Standards for Transfer of Data...

  17. Supervised local error estimation for nonlinear image registration using convolutional neural networks

    NARCIS (Netherlands)

    Eppenhof, Koen A.J.; Pluim, Josien P.W.; Styner, M.A.; Angelini, E.D.

    2017-01-01

    Error estimation in medical image registration is valuable when validating, comparing, or combining registration methods. To validate a nonlinear image registration method, ideally the registration error should be known for the entire image domain. We propose a supervised method for the estimation

  18. Mid-space-independent deformable image registration.

    Science.gov (United States)

    Aganj, Iman; Iglesias, Juan Eugenio; Reuter, Martin; Sabuncu, Mert Rory; Fischl, Bruce

    2017-05-15

    Aligning images in a mid-space is a common approach to ensuring that deformable image registration is symmetric - that it does not depend on the arbitrary ordering of the input images. The results are, however, generally dependent on the mathematical definition of the mid-space. In particular, the set of possible solutions is typically restricted by the constraints that are enforced on the transformations to prevent the mid-space from drifting too far from the native image spaces. The use of an implicit atlas has been proposed as an approach to mid-space image registration. In this work, we show that when the atlas is aligned to each image in the native image space, the data term of implicit-atlas-based deformable registration is inherently independent of the mid-space. In addition, we show that the regularization term can be reformulated independently of the mid-space as well. We derive a new symmetric cost function that only depends on the transformation morphing the images to each other, rather than to the atlas. This eliminates the need for anti-drift constraints, thereby expanding the space of allowable deformations. We provide an implementation scheme for the proposed framework, and validate it through diffeomorphic registration experiments on brain magnetic resonance images. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. 75 FR 65667 - Lincoln Pharmacy; Revocation of Registration

    Science.gov (United States)

    2010-10-26

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Lincoln Pharmacy; Revocation of Registration... Order to Show Cause and Immediate Suspension of Registration (Order) to Lincoln Pharmacy (Respondent... pharmacy located at 52 Lincoln Highway, Edison, New Jersey, which is owned and operated by Mr. Vincent Hsia...

  20. CINERGI: Community Inventory of EarthCube Resources for Geoscience Interoperability

    Science.gov (United States)

    Zaslavsky, Ilya; Bermudez, Luis; Grethe, Jeffrey; Gupta, Amarnath; Hsu, Leslie; Lehnert, Kerstin; Malik, Tanu; Richard, Stephen; Valentine, David; Whitenack, Thomas

    2014-05-01

    Organizing geoscience data resources to support cross-disciplinary data discovery, interpretation, analysis and integration is challenging because of different information models, semantic frameworks, metadata profiles, catalogs, and services used in different geoscience domains, not to mention different research paradigms and methodologies. The central goal of CINERGI, a new project supported by the US National Science Foundation through its EarthCube Building Blocks program, is to create a methodology and assemble a large inventory of high-quality information resources capable of supporting data discovery needs of researchers in a wide range of geoscience domains. The key characteristics of the inventory are: 1) collaboration with and integration of metadata resources from a number of large data facilities; 2) reliance on international metadata and catalog service standards; 3) assessment of resource "interoperability-readiness"; 4) ability to cross-link and navigate data resources, projects, models, researcher directories, publications, usage information, etc.; 5) efficient inclusion of "long-tail" data, which are not appearing in existing domain repositories; 6) data registration at feature level where appropriate, in addition to common dataset-level registration, and 7) integration with parallel EarthCube efforts, in particular focused on EarthCube governance, information brokering, service-oriented architecture design and management of semantic information. We discuss challenges associated with accomplishing CINERGI goals, including defining the inventory scope; managing different granularity levels of resource registration; interaction with search systems of domain repositories; explicating domain semantics; metadata brokering, harvesting and pruning; managing provenance of the harvested metadata; and cross-linking resources based on the linked open data (LOD) approaches. At the higher level of the inventory, we register domain-wide resources such as domain

  1. Fast and accurate registration of cranial CT images with A-mode ultrasound.

    Science.gov (United States)

    Fieten, Lorenz; Schmieder, Kirsten; Engelhardt, Martin; Pasalic, Lamija; Radermacher, Klaus; Heger, Stefan

    2009-05-01

    Within the CRANIO project, a navigation module based on preoperative computed tomography (CT) data was developed for Computer and Robot Assisted Neurosurgery. The approach followed for non-invasive user-interactive registration of cranial CT images with the physical operating space consists of surface-based registration following pre-registration based on anatomical landmarks. Surface-based registration relies on bone surface points digitized transcutaneously by means of an optically tracked A-mode ultrasound (US) probe. As probe alignment and thus bone surface point digitization may be time-consuming, we investigated how to obtain high registration accuracy despite inaccurate pre-registration and a limited number of digitized bone surface points. Furthermore, we aimed at efficient man-machine-interaction during the probe alignment process. Finally, we addressed the problem of registration plausibility estimation in our approach. We modified the Iterative Closest Point (ICP) algorithm, presented by Besl and McKay and frequently used for surface-based registration, such that it can escape from local minima of the cost function to be iteratively minimized. The random-based ICP (R-ICP) we developed is less influenced by the quality of the pre-registration as it can escape from local minima close to the starting point for iterative optimization in the 6D domain of rigid transformations. The R-ICP is also better suited to approximate the global minimum as it can escape from local minima in the vicinity of the global minimum, too. Furthermore, we developed both CT-less and CT-based probe alignment tools along with appropriate man-machine strategies for a more time-efficient palpation process. To improve registration reliability, we developed a simple plausibility test based on data readily available after registration. In a cadaver study, where we evaluated the R-ICP algorithm, the probe alignment tools, and the plausibility test, the R-ICP algorithm consistently

  2. Improving Intensity-Based Lung CT Registration Accuracy Utilizing Vascular Information

    Directory of Open Access Journals (Sweden)

    Kunlin Cao

    2012-01-01

    Full Text Available Accurate pulmonary image registration is a challenging problem when the lungs have a deformation with large distance. In this work, we present a nonrigid volumetric registration algorithm to track lung motion between a pair of intrasubject CT images acquired at different inflation levels and introduce a new vesselness similarity cost that improves intensity-only registration. Volumetric CT datasets from six human subjects were used in this study. The performance of four intensity-only registration algorithms was compared with and without adding the vesselness similarity cost function. Matching accuracy was evaluated using landmarks, vessel tree, and fissure planes. The Jacobian determinant of the transformation was used to reveal the deformation pattern of local parenchymal tissue. The average matching error for intensity-only registration methods was on the order of 1 mm at landmarks and 1.5 mm on fissure planes. After adding the vesselness preserving cost function, the landmark and fissure positioning errors decreased approximately by 25% and 30%, respectively. The vesselness cost function effectively helped improve the registration accuracy in regions near thoracic cage and near the diaphragm for all the intensity-only registration algorithms tested and also helped produce more consistent and more reliable patterns of regional tissue deformation.

  3. Diffusion Maps for Multimodal Registration

    Directory of Open Access Journals (Sweden)

    Gemma Piella

    2014-06-01

    Full Text Available Multimodal image registration is a difficult task, due to the significant intensity variations between the images. A common approach is to use sophisticated similarity measures, such as mutual information, that are robust to those intensity variations. However, these similarity measures are computationally expensive and, moreover, often fail to capture the geometry and the associated dynamics linked with the images. Another approach is the transformation of the images into a common space where modalities can be directly compared. Within this approach, we propose to register multimodal images by using diffusion maps to describe the geometric and spectral properties of the data. Through diffusion maps, the multimodal data is transformed into a new set of canonical coordinates that reflect its geometry uniformly across modalities, so that meaningful correspondences can be established between them. Images in this new representation can then be registered using a simple Euclidean distance as a similarity measure. Registration accuracy was evaluated on both real and simulated brain images with known ground-truth for both rigid and non-rigid registration. Results showed that the proposed approach achieved higher accuracy than the conventional approach using mutual information.

  4. Reforming birth registration law in England and Wales?

    Directory of Open Access Journals (Sweden)

    Julie McCandless

    2017-06-01

    Full Text Available The Law Commission of England and Wales is considering what its 13th Programme of Law Reform should address. During the consultation process, a project on birth registration law has been mooted. This is a very welcome proposal given that civil birth registration in England and Wales is a compulsory procedure that not only finds its roots in the early Victorian era, but also remains very similar, at least in terms of form and the information that is recorded. I first use two recent legal challenges to illustrate why the current system is coming under increasing pressure. I further use these examples to caution against a law reform agenda that is narrowly focused on the precise information recorded, without a preliminary and wider examination of what the role and purpose of birth registration is, and should be, in society. I argue that this needs to be addressed before the state can justify the parameters of the information recorded. I then use an outline of historical reforms relating to the registration of births outside of marriage to highlight the normative two-parent family model that underpins the birth registration system. I argue that legal reform must be cognizant of the tenacity of this normative family model, particularly in relation to reform proposals surrounding donor conception and the annotation of birth certificates. Finally, I draw attention to wider developments in family law that cast birth registration as a social policy tool for the facilitation of parent–child relationships, particularly unmarried fathers.

  5. A multicore based parallel image registration method.

    Science.gov (United States)

    Yang, Lin; Gong, Leiguang; Zhang, Hong; Nosher, John L; Foran, David J

    2009-01-01

    Image registration is a crucial step for many image-assisted clinical applications such as surgery planning and treatment evaluation. In this paper we proposed a landmark based nonlinear image registration algorithm for matching 2D image pairs. The algorithm was shown to be effective and robust under conditions of large deformations. In landmark based registration, the most important step is establishing the correspondence among the selected landmark points. This usually requires an extensive search which is often computationally expensive. We introduced a nonregular data partition algorithm using the K-means clustering algorithm to group the landmarks based on the number of available processing cores. The step optimizes the memory usage and data transfer. We have tested our method using IBM Cell Broadband Engine (Cell/B.E.) platform.

  6. WE-H-202-04: Advanced Medical Image Registration Techniques

    International Nuclear Information System (INIS)

    Christensen, G.

    2016-01-01

    Deformable image registration has now been commercially available for several years, with solid performance in a number of sites and for several applications including contour and dose mapping. However, more complex applications have arisen, such as assessing response to radiation therapy over time, registering images pre- and post-surgery, and auto-segmentation from atlases. These applications require innovative registration algorithms to achieve accurate alignment. The goal of this session is to highlight emerging registration technology and these new applications. The state of the art in image registration will be presented from an engineering perspective. Translational clinical applications will also be discussed to tie these new registration approaches together with imaging and radiation therapy applications in specific diseases such as cervical and lung cancers. Learning Objectives: To understand developing techniques and algorithms in deformable image registration that are likely to translate into clinical tools in the near future. To understand emerging imaging and radiation therapy clinical applications that require such new registration algorithms. Research supported in part by the National Institutes of Health under award numbers P01CA059827, R01CA166119, and R01CA166703. Disclosures: Phillips Medical systems (Hugo), Roger Koch (Christensen) support, Varian Medical Systems (Brock), licensing agreements from Raysearch (Brock) and Varian (Hugo).; K. Brock, Licensing Agreement - RaySearch Laboratories. Research Funding - Varian Medical Systems; G. Hugo, Research grant from National Institutes of Health, award number R01CA166119.; G. Christensen, Research support from NIH grants CA166119 and CA166703 and a gift from Roger Koch. There are no conflicts of interest.

  7. WE-H-202-04: Advanced Medical Image Registration Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, G. [University of Iowa (United States)

    2016-06-15

    Deformable image registration has now been commercially available for several years, with solid performance in a number of sites and for several applications including contour and dose mapping. However, more complex applications have arisen, such as assessing response to radiation therapy over time, registering images pre- and post-surgery, and auto-segmentation from atlases. These applications require innovative registration algorithms to achieve accurate alignment. The goal of this session is to highlight emerging registration technology and these new applications. The state of the art in image registration will be presented from an engineering perspective. Translational clinical applications will also be discussed to tie these new registration approaches together with imaging and radiation therapy applications in specific diseases such as cervical and lung cancers. Learning Objectives: To understand developing techniques and algorithms in deformable image registration that are likely to translate into clinical tools in the near future. To understand emerging imaging and radiation therapy clinical applications that require such new registration algorithms. Research supported in part by the National Institutes of Health under award numbers P01CA059827, R01CA166119, and R01CA166703. Disclosures: Phillips Medical systems (Hugo), Roger Koch (Christensen) support, Varian Medical Systems (Brock), licensing agreements from Raysearch (Brock) and Varian (Hugo).; K. Brock, Licensing Agreement - RaySearch Laboratories. Research Funding - Varian Medical Systems; G. Hugo, Research grant from National Institutes of Health, award number R01CA166119.; G. Christensen, Research support from NIH grants CA166119 and CA166703 and a gift from Roger Koch. There are no conflicts of interest.

  8. Some Registral Features of Matrimonial Advertisement in Indian English

    Science.gov (United States)

    Mehrotra, R. R.

    1975-01-01

    Examines these distinct registral features of matrimonial newspaper advertisements in English in India: incongruity, deletion of preposition, miscellaneous deletions, two-word sentence, new abbreviations, registral confusion, stylistic variation. (RM)

  9. 76 FR 4072 - Registration of Claims of Copyright

    Science.gov (United States)

    2011-01-24

    ... of published photographs should contact the Visual Arts Division for permission and guidance on... online registration has been available for basic registration claims, it has not yet been made generally... is registered is primarily photographic in nature. In fact, the Visual Arts Division has accepted...

  10. 75 FR 44655 - Registration of Mortgage Loan Originators

    Science.gov (United States)

    2010-07-28

    ... State licensing and registration must be accomplished through the same online registration system, the... noting that the exceptions should not be structured to benefit only small institutions. \\1\\ 12 U.S.C... gaming opportunities essentially unrealistic. Many commenters noted the complexity of the proposed...

  11. 76 FR 6185 - Registration of Mortgage Loan Originators

    Science.gov (United States)

    2011-02-03

    ... UNION ADMINISTRATION Registration of Mortgage Loan Originators AGENCY: Office of the Comptroller of the..., Agency-regulated institutions) who act as a residential mortgage loan originator to register with the... registration system for mortgage loan originators. Specifically, the Act requires: (1) All States to provide...

  12. A novel Gravity-FREAK feature extraction and Gravity-KLT tracking registration algorithm based on iPhone MEMS mobile sensor in mobile environment.

    Science.gov (United States)

    Hong, Zhiling; Lin, Fan; Xiao, Bin

    2017-01-01

    Based on the traditional Fast Retina Keypoint (FREAK) feature description algorithm, this paper proposed a Gravity-FREAK feature description algorithm based on Micro-electromechanical Systems (MEMS) sensor to overcome the limited computing performance and memory resources of mobile devices and further improve the reality interaction experience of clients through digital information added to the real world by augmented reality technology. The algorithm takes the gravity projection vector corresponding to the feature point as its feature orientation, which saved the time of calculating the neighborhood gray gradient of each feature point, reduced the cost of calculation and improved the accuracy of feature extraction. In the case of registration method of matching and tracking natural features, the adaptive and generic corner detection based on the Gravity-FREAK matching purification algorithm was used to eliminate abnormal matches, and Gravity Kaneda-Lucas Tracking (KLT) algorithm based on MEMS sensor can be used for the tracking registration of the targets and robustness improvement of tracking registration algorithm under mobile environment.

  13. Canny edge-based deformable image registration.

    Science.gov (United States)

    Kearney, Vasant; Huang, Yihui; Mao, Weihua; Yuan, Baohong; Tang, Liping

    2017-02-07

    This work focuses on developing a 2D Canny edge-based deformable image registration (Canny DIR) algorithm to register in vivo white light images taken at various time points. This method uses a sparse interpolation deformation algorithm to sparsely register regions of the image with strong edge information. A stability criterion is enforced which removes regions of edges that do not deform in a smooth uniform manner. Using a synthetic mouse surface ground truth model, the accuracy of the Canny DIR algorithm was evaluated under axial rotation in the presence of deformation. The accuracy was also tested using fluorescent dye injections, which were then used for gamma analysis to establish a second ground truth. The results indicate that the Canny DIR algorithm performs better than rigid registration, intensity corrected Demons, and distinctive features for all evaluation matrices and ground truth scenarios. In conclusion Canny DIR performs well in the presence of the unique lighting and shading variations associated with white-light-based image registration.

  14. Automated landmark-guided deformable image registration.

    Science.gov (United States)

    Kearney, Vasant; Chen, Susie; Gu, Xuejun; Chiu, Tsuicheng; Liu, Honghuan; Jiang, Lan; Wang, Jing; Yordy, John; Nedzi, Lucien; Mao, Weihua

    2015-01-07

    The purpose of this work is to develop an automated landmark-guided deformable image registration (LDIR) algorithm between the planning CT and daily cone-beam CT (CBCT) with low image quality. This method uses an automated landmark generation algorithm in conjunction with a local small volume gradient matching search engine to map corresponding landmarks between the CBCT and the planning CT. The landmarks act as stabilizing control points in the following Demons deformable image registration. LDIR is implemented on graphics processing units (GPUs) for parallel computation to achieve ultra fast calculation. The accuracy of the LDIR algorithm has been evaluated on a synthetic case in the presence of different noise levels and data of six head and neck cancer patients. The results indicate that LDIR performed better than rigid registration, Demons, and intensity corrected Demons for all similarity metrics used. In conclusion, LDIR achieves high accuracy in the presence of multimodality intensity mismatch and CBCT noise contamination, while simultaneously preserving high computational efficiency.

  15. Automated landmark-guided deformable image registration

    International Nuclear Information System (INIS)

    Kearney, Vasant; Chen, Susie; Gu, Xuejun; Chiu, Tsuicheng; Liu, Honghuan; Jiang, Lan; Wang, Jing; Yordy, John; Nedzi, Lucien; Mao, Weihua

    2015-01-01

    The purpose of this work is to develop an automated landmark-guided deformable image registration (LDIR) algorithm between the planning CT and daily cone-beam CT (CBCT) with low image quality. This method uses an automated landmark generation algorithm in conjunction with a local small volume gradient matching search engine to map corresponding landmarks between the CBCT and the planning CT. The landmarks act as stabilizing control points in the following Demons deformable image registration. LDIR is implemented on graphics processing units (GPUs) for parallel computation to achieve ultra fast calculation. The accuracy of the LDIR algorithm has been evaluated on a synthetic case in the presence of different noise levels and data of six head and neck cancer patients. The results indicate that LDIR performed better than rigid registration, Demons, and intensity corrected Demons for all similarity metrics used. In conclusion, LDIR achieves high accuracy in the presence of multimodality intensity mismatch and CBCT noise contamination, while simultaneously preserving high computational efficiency. (paper)

  16. 77 FR 43078 - Federal Acquisition Regulation; Information Collection; Central Contractor Registration

    Science.gov (United States)

    2012-07-23

    ...; Information Collection; Central Contractor Registration AGENCY: Department of Defense (DOD), General Services... requirement concerning the Central Contractor Registration database. Public comments are particularly invited... Information Collection 9000- 0159, Central Contractor Registration, by any of the following methods...

  17. Gaussian Process Interpolation for Uncertainty Estimation in Image Registration

    Science.gov (United States)

    Wachinger, Christian; Golland, Polina; Reuter, Martin; Wells, William

    2014-01-01

    Intensity-based image registration requires resampling images on a common grid to evaluate the similarity function. The uncertainty of interpolation varies across the image, depending on the location of resampled points relative to the base grid. We propose to perform Bayesian inference with Gaussian processes, where the covariance matrix of the Gaussian process posterior distribution estimates the uncertainty in interpolation. The Gaussian process replaces a single image with a distribution over images that we integrate into a generative model for registration. Marginalization over resampled images leads to a new similarity measure that includes the uncertainty of the interpolation. We demonstrate that our approach increases the registration accuracy and propose an efficient approximation scheme that enables seamless integration with existing registration methods. PMID:25333127

  18. 78 FR 12316 - Federal Acquisition Regulation; Information Collection; Central Contractor Registration

    Science.gov (United States)

    2013-02-22

    ...; Information Collection; Central Contractor Registration AGENCIES: Department of Defense (DOD), General... collection requirement concerning the Central Contractor Registration database. A notice was published in the... Information Collection 9000- 0159, Central Contractor Registration, by any of the following methods...

  19. Improving alignment in Tract-based spatial statistics: evaluation and optimization of image registration.

    Science.gov (United States)

    de Groot, Marius; Vernooij, Meike W; Klein, Stefan; Ikram, M Arfan; Vos, Frans M; Smith, Stephen M; Niessen, Wiro J; Andersson, Jesper L R

    2013-08-01

    Anatomical alignment in neuroimaging studies is of such importance that considerable effort is put into improving the registration used to establish spatial correspondence. Tract-based spatial statistics (TBSS) is a popular method for comparing diffusion characteristics across subjects. TBSS establishes spatial correspondence using a combination of nonlinear registration and a "skeleton projection" that may break topological consistency of the transformed brain images. We therefore investigated feasibility of replacing the two-stage registration-projection procedure in TBSS with a single, regularized, high-dimensional registration. To optimize registration parameters and to evaluate registration performance in diffusion MRI, we designed an evaluation framework that uses native space probabilistic tractography for 23 white matter tracts, and quantifies tract similarity across subjects in standard space. We optimized parameters for two registration algorithms on two diffusion datasets of different quality. We investigated reproducibility of the evaluation framework, and of the optimized registration algorithms. Next, we compared registration performance of the regularized registration methods and TBSS. Finally, feasibility and effect of incorporating the improved registration in TBSS were evaluated in an example study. The evaluation framework was highly reproducible for both algorithms (R(2) 0.993; 0.931). The optimal registration parameters depended on the quality of the dataset in a graded and predictable manner. At optimal parameters, both algorithms outperformed the registration of TBSS, showing feasibility of adopting such approaches in TBSS. This was further confirmed in the example experiment. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. 76 FR 77824 - Dicofol; Cancellation Order for Certain Pesticide Registrations

    Science.gov (United States)

    2011-12-14

    ..., sale, or use of existing stocks of the products identified in Tables 1 and 2 of Unit II in a manner..., 2011 Federal Register Notice of Receipt of Requests from the registrants listed in Table 3 of Unit II.... These registrations are listed in sequence by registration number in Table 1 and Table 2 of this unit...

  1. Unified voxel- and tensor-based morphometry (UVTBM) using registration confidence.

    Science.gov (United States)

    Khan, Ali R; Wang, Lei; Beg, Mirza Faisal

    2015-01-01

    Voxel-based morphometry (VBM) and tensor-based morphometry (TBM) both rely on spatial normalization to a template and yet have different requirements for the level of registration accuracy. VBM requires only global alignment of brain structures, with limited degrees of freedom in transformation, whereas TBM performs best when the registration is highly deformable and can achieve higher registration accuracy. In addition, the registration accuracy varies over the whole brain, with higher accuracy typically observed in subcortical areas and lower accuracy seen in cortical areas. Hence, even the determinant of Jacobian of registration maps is spatially varying in their accuracy, and combining these with VBM by direct multiplication introduces errors in VBM maps where the registration is inaccurate. We propose a unified approach to combining these 2 morphometry methods that is motivated by these differing requirements for registration and our interest in harnessing the advantages of both. Our novel method uses local estimates of registration confidence to determine how to weight the influence of VBM- and TBM-like approaches. Results are shown on healthy and mild Alzheimer's subjects (N = 150) investigating age and group differences, and potential of differential diagnosis is shown on a set of Alzheimer's disease (N = 34) and frontotemporal dementia (N = 30) patients compared against controls (N = 14). These show that the group differences detected by our proposed approach are more descriptive than those detected from VBM, Jacobian-modulated VBM, and TBM separately, hence leveraging the advantages of both approaches in a unified framework. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. 75 FR 35805 - Pesticide Product Registrations; Conditional Approvals

    Science.gov (United States)

    2010-06-23

    ... submitted by April 1, 2009. 5. Insect Resistance Management: To support sweet corn uses, baseline... support these registrations, except for material specifically protected by section 10 of FIFRA, are also... following data/information must be submitted to the Agency to support the registration of MON 89034: 1...

  3. CO-REGISTRATION AIRBORNE LIDAR POINT CLOUD DATA AND SYNCHRONOUS DIGITAL IMAGE REGISTRATION BASED ON COMBINED ADJUSTMENT

    Directory of Open Access Journals (Sweden)

    Z. H. Yang

    2016-06-01

    Full Text Available Aim at the problem of co-registration airborne laser point cloud data with the synchronous digital image, this paper proposed a registration method based on combined adjustment. By integrating tie point, point cloud data with elevation constraint pseudo observations, using the principle of least-squares adjustment to solve the corrections of exterior orientation elements of each image, high-precision registration results can be obtained. In order to ensure the reliability of the tie point, and the effectiveness of pseudo observations, this paper proposed a point cloud data constrain SIFT matching and optimizing method, can ensure that the tie points are located on flat terrain area. Experiments with the airborne laser point cloud data and its synchronous digital image, there are about 43 pixels error in image space using the original POS data. If only considering the bore-sight of POS system, there are still 1.3 pixels error in image space. The proposed method regards the corrections of the exterior orientation elements of each image as unknowns and the errors are reduced to 0.15 pixels.

  4. Registration of acute stroke

    DEFF Research Database (Denmark)

    Wildenschild, Cathrine; Mehnert, Frank; Thomsen, Reimar Wernich

    2014-01-01

    BACKGROUND: The validity of the registration of patients in stroke-specific registries has seldom been investigated, nor compared with administrative hospital discharge registries. The objective of this study was to examine the validity of the registration of patients in a stroke-specific registry...... (The Danish Stroke Registry [DSR]) and a hospital discharge registry (The Danish National Patient Registry [DNRP]). METHODS: Assuming that all patients with stroke were registered in either the DSR, DNRP or both, we first identified a sample of 75 patients registered with stroke in 2009; 25 patients...... in the DSR, 25 patients in the DNRP, and 25 patients registered in both data sources. Using the medical record as a gold standard, we then estimated the sensitivity and positive predictive value of a stroke diagnosis in the DSR and the DNRP. Secondly, we reviewed 160 medical records for all potential stroke...

  5. The development of machine technology processing for earth resource survey

    Science.gov (United States)

    Landgrebe, D. A.

    1970-01-01

    The following technologies are considered for automatic processing of earth resources data: (1) registration of multispectral and multitemporal images, (2) digital image display systems, (3) data system parameter effects on satellite remote sensing systems, and (4) data compression techniques based on spectral redundancy. The importance of proper spectral band and compression algorithm selections is pointed out.

  6. Evaluation of registration methods on thoracic CT

    DEFF Research Database (Denmark)

    Murphy, K.; van Ginneken, B.; Reinhardt, J.

    2011-01-01

    method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing......EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intra-patient thoracic CT image pairs. Evaluation of non-rigid registration techniques is a non trivial task....... This article details the organisation of the challenge, the data and evaluation methods and the outcome of the initial launch with 20 algorithms. The gain in knowledge and future work are discussed....

  7. [Nordic accident classification system used in the Danish National Hospital Registration System to register causes of severe traumatic brain injury].

    Science.gov (United States)

    Engberg, Aase Worsaa; Penninga, Elisabeth Irene; Teasdale, Thomas William

    2007-11-05

    The purpose was to illustrate the use of the accident classification system worked out by the Nordic Medico-Statistical Committee (NOMESCO). In particular, registration of causes of severe traumatic brain injury according to the system as part of the Danish National Hospital Registration System was studied. The study comprised 117 patients with very severe traumatic brain injury (TBI) admitted to the Brain Injury Unit of the University Hospital in Hvidovre, Copenhagen, from 1 October 2000 to 30 September 2002. Prospective NOMESCO coding at discharge was compared to independent retrospective coding based on hospital records, and to coding from other wards in the Danish National Hospital Registration System. Furthermore, sets of codes in the Danish National Hospital Registration System for consecutive admissions after a particular accident were compared. Identical results of prospective and independent retrospective coding were found for 65% of 588 single codes, and complete sets of codes for the same accident were identical only in 28% of cases. Sets of codes for the first admission in a hospital course corresponded to retrospective coding at the end of the course in only 17% of cases. Accident code sets from different wards, based on the same injury, were identical in only 7% of cases. Prospective coding by the NOMESCO accident classification system proved problematic, both with regard to correctness and completeness. The system--although logical--seems too complicated compared to the resources invested in the coding. The results of this investigation stress the need for better management and for better instruction to those who carry out the registration.

  8. Image Segmentation, Registration, Compression, and Matching

    Science.gov (United States)

    Yadegar, Jacob; Wei, Hai; Yadegar, Joseph; Ray, Nilanjan; Zabuawala, Sakina

    2011-01-01

    A novel computational framework was developed of a 2D affine invariant matching exploiting a parameter space. Named as affine invariant parameter space (AIPS), the technique can be applied to many image-processing and computer-vision problems, including image registration, template matching, and object tracking from image sequence. The AIPS is formed by the parameters in an affine combination of a set of feature points in the image plane. In cases where the entire image can be assumed to have undergone a single affine transformation, the new AIPS match metric and matching framework becomes very effective (compared with the state-of-the-art methods at the time of this reporting). No knowledge about scaling or any other transformation parameters need to be known a priori to apply the AIPS framework. An automated suite of software tools has been created to provide accurate image segmentation (for data cleaning) and high-quality 2D image and 3D surface registration (for fusing multi-resolution terrain, image, and map data). These tools are capable of supporting existing GIS toolkits already in the marketplace, and will also be usable in a stand-alone fashion. The toolkit applies novel algorithmic approaches for image segmentation, feature extraction, and registration of 2D imagery and 3D surface data, which supports first-pass, batched, fully automatic feature extraction (for segmentation), and registration. A hierarchical and adaptive approach is taken for achieving automatic feature extraction, segmentation, and registration. Surface registration is the process of aligning two (or more) data sets to a common coordinate system, during which the transformation between their different coordinate systems is determined. Also developed here are a novel, volumetric surface modeling and compression technique that provide both quality-guaranteed mesh surface approximations and compaction of the model sizes by efficiently coding the geometry and connectivity

  9. Using mobile electronic devices to deliver educational resources in developing countries.

    Science.gov (United States)

    Mazal, Jonathan Robert; Ludwig, Rebecca

    2015-01-01

    Developing countries have far fewer trained radiography professionals than developed countries, which exacerbates the limited access to imaging services. The lack of trained radiographers reflects, in part, limited availability of radiographer-specific educational resources. Historically, organizations that provided such resources in the developing world faced challenges related to the limited stock of current materials as well as expenses associated with shipping and delivery. Four mobile electronic devices (MEDs) were loaded with educational content (e-books, PDFs, and digital applications) spanning major radiography topics. The MEDs were distributed to 4 imaging departments in Ghana, India, Nepal, and Nigeria based on evidence of need for radiography-specific resources, as revealed by survey responses. A cost comparison of postal delivery vs digital delivery of educational content was performed. The effectiveness of delivering additional content via Wi-Fi transmission also was evaluated. Feedback was solicited on users' experience with the MEDs as a delivery tool for educational content. An initial average per e-book expense of $30.05, which included the cost of the device, was calculated for the MED delivery method compared with $15.56 for postal delivery of printed materials. The cost of the MED delivery method was reduced to an average of $10.05 for subsequent e-book deliveries. Additional content was successfully delivered via Wi-Fi transmission to all recipients during the 3-month follow-up period. Overall user feedback on the experience was positive, and ideas for enhancing the MED-based method were identified. Using MEDs to deliver radiography-specific educational content appears to be more cost effective than postal delivery of printed materials on a long-term basis. MEDs are more efficient for providing updates to educational materials. Customization of content to department needs, and using projector devices could enhance the usefulness of MEDs for

  10. Comparison of manual and automatic MR-CT registration for radiotherapy of prostate cancer.

    Science.gov (United States)

    Korsager, Anne Sofie; Carl, Jesper; Riis Østergaard, Lasse

    2016-05-08

    In image-guided radiotherapy (IGRT) of prostate cancer, delineation of the clini-cal target volume (CTV) often relies on magnetic resonance (MR) because of its good soft-tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR-CT registration of the prostate has previously been developed using a voxel property-based registration as an alternative to a manual landmark-based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni-Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration.

  11. 3D Rigid Registration by Cylindrical Phase Correlation Method

    Czech Academy of Sciences Publication Activity Database

    Bican, Jakub; Flusser, Jan

    2009-01-01

    Roč. 30, č. 10 (2009), s. 914-921 ISSN 0167-8655 R&D Projects: GA MŠk 1M0572; GA ČR GA102/08/1593 Grant - others:GAUK(CZ) 48908 Institutional research plan: CEZ:AV0Z10750506 Keywords : 3D registration * correlation methods * Image registration Subject RIV: BD - Theory of Information Impact factor: 1.303, year: 2009 http://library.utia.cas.cz/separaty/2009/ZOI/bican-3d digit registration by cylindrical phase correlation method.pdf

  12. Multimodal image registration based on binary gradient angle descriptor.

    Science.gov (United States)

    Jiang, Dongsheng; Shi, Yonghong; Yao, Demin; Fan, Yifeng; Wang, Manning; Song, Zhijian

    2017-12-01

    Multimodal image registration plays an important role in image-guided interventions/therapy and atlas building, and it is still a challenging task due to the complex intensity variations in different modalities. The paper addresses the problem and proposes a simple, compact, fast and generally applicable modality-independent binary gradient angle descriptor (BGA) based on the rationale of gradient orientation alignment. The BGA can be easily calculated at each voxel by coding the quadrant in which a local gradient vector falls, and it has an extremely low computational complexity, requiring only three convolutions, two multiplication operations and two comparison operations. Meanwhile, the binarized encoding of the gradient orientation makes the BGA more resistant to image degradations compared with conventional gradient orientation methods. The BGA can extract similar feature descriptors for different modalities and enable the use of simple similarity measures, which makes it applicable within a wide range of optimization frameworks. The results for pairwise multimodal and monomodal registrations between various images (T1, T2, PD, T1c, Flair) consistently show that the BGA significantly outperforms localized mutual information. The experimental results also confirm that the BGA can be a reliable alternative to the sum of absolute difference in monomodal image registration. The BGA can also achieve an accuracy of [Formula: see text], similar to that of the SSC, for the deformable registration of inhale and exhale CT scans. Specifically, for the highly challenging deformable registration of preoperative MRI and 3D intraoperative ultrasound images, the BGA achieves a similar registration accuracy of [Formula: see text] compared with state-of-the-art approaches, with a computation time of 18.3 s per case. The BGA improves the registration performance in terms of both accuracy and time efficiency. With further acceleration, the framework has the potential for

  13. Venue-level correlates of female sex worker registration status: A multilevel analysis of bars in Tijuana, Mexico

    Science.gov (United States)

    Gaines, Tommi L.; Rusch, Melanie L.A.; Brouwer, Kimberly C.; Goldenberg, Shira M.; Lozada, Remedios; Robertson, Angela M.; Perkins, Emily; Strathdee, Steffanie A.; Patterson, Thomas L.

    2013-01-01

    In Tijuana, Mexico, sex work is regulated by the municipal government, through registration cards issued to female sex workers (FSWs) for an annual fee. Registration has been associated with decreased drug use and increase condom use and HIV testing. Previously, it was demonstrated that FSWs operating in bars were more likely than street-based FSWs to be registered. This implies that certain venues may be more accessible to local authorities for the enforcement of this type of programme. Taking a novel multilevel approach, we examined whether venue characteristics of bars reflecting greater organised management and visibility affect registration status of FSWs. In an analysis of venue-level characteristics, predictors of being registered were availability of free condoms at work and distance to the main sex strip; however, these were not independently associated after inclusion of FSWs’ income, illicit drug use and history of HIV testing. Our findings suggest that sex work regulations may inadvertently exclude venues in which the more vulnerable and less visible FSWs, such as injection drug users and those with limited financial resources, are situated. Efforts to revise or reconsider sex work regulations to ensure that they best promote FSWs’ health, human and labour rights are recommended. PMID:23534477

  14. Venue-level correlates of female sex worker registration status: a multilevel analysis of bars in Tijuana, Mexico.

    Science.gov (United States)

    Gaines, Tommi L; Rusch, Melanie L A; Brouwer, Kimberly C; Goldenberg, Shira M; Lozada, Remedios; Robertson, Angela M; Perkins, Emily; Strathdee, Steffanie A; Patterson, Thomas L

    2013-01-01

    In Tijuana, Mexico, sex work is regulated by the municipal government, through registration cards issued to female sex workers (FSWs) for an annual fee. Registration has been associated with decreased drug use and increase condom use and HIV testing. Previously, it was demonstrated that FSWs operating in bars were more likely than street-based FSWs to be registered. This implies that certain venues may be more accessible to local authorities for the enforcement of this type of programme. Taking a novel multilevel approach, we examined whether venue characteristics of bars reflecting greater organised management and visibility affect registration status of FSWs. In an analysis of venue-level characteristics, predictors of being registered were availability of free condoms at work and distance to the main sex strip; however, these were not independently associated after inclusion of FSWs' income, illicit drug use and history of HIV testing. Our findings suggest that sex work regulations may inadvertently exclude venues in which the more vulnerable and less visible FSWs, such as injection drug users and those with limited financial resources, are situated. Efforts to revise or reconsider sex work regulations to ensure that they best promote FSWs' health, human and labour rights are recommended.

  15. Success criteria for electronic medical record implementations in low-resource settings: a systematic review.

    Science.gov (United States)

    Fritz, Fleur; Tilahun, Binyam; Dugas, Martin

    2015-03-01

    Electronic medical record (EMR) systems have the potential of supporting clinical work by providing the right information at the right time to the right people and thus make efficient use of resources. This is especially important in low-resource settings where reliable data are also needed to support public health and local supporting organizations. In this systematic literature review, our objectives are to identify and collect literature about success criteria of EMR implementations in low-resource settings and to summarize them into recommendations. Our search strategy relied on PubMed queries and manual bibliography reviews. Studies were included if EMR implementations in low-resource settings were described. The extracted success criteria and measurements were summarized into 7 categories: ethical, financial, functionality, organizational, political, technical, and training. We collected 381 success criteria with 229 measurements from 47 articles out of 223 articles. Most papers were evaluations or lessons learned from African countries, published from 1999 to 2013. Almost half of the EMR systems served a specific disease area like human immunodeficiency virus (HIV). The majority of criteria that were reported dealt with the functionality, followed by organizational issues, and technical infrastructures. Sufficient training and skilled personnel were mentioned in roughly 10%. Political, ethical, and financial considerations did not play a predominant role. More evaluations based on reliable frameworks are needed. Highly reliable data handling methods, human resources and effective project management, as well as technical architecture and infrastructure are all key factors for successful EMR implementation. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Event Registration System for INR Linac

    International Nuclear Information System (INIS)

    Grekhov, O.V.; Drugakov, A.N.; Kiselev, Yu.V.

    2006-01-01

    The software of the Event registration system for the linear accelerators is described. This system allows receiving of the information on changes of operating modes of the accelerator and supervising of hundreds of key parameters of various systems of the accelerator. The Event registration system consists of the source and listeners of events. The sources of events are subroutines built in existing ACS Linac. The listeners of events are software Supervisor and Client ERS. They are used for warning the operator about change controlled parameter of the accelerator

  17. Evaluation of registration methods on thoracic CT : the EMPIRE10 challenge

    NARCIS (Netherlands)

    Murphy, K.; Ginneken, van B.; Reinhardt, J.M.; Kabus, S.; Ding, K.; Deng, Xiang; Cao, K.; Du, K.; Christensen, G.E.; Garcia, V.; Vercauteren, T.; Ayache, N.; Commowick, O.; Malandain, G.; Glocker, B.; Paragios, N.; Navab, N.; Gorbunova, V.; Sporring, J.; Bruijne, de M.; Han, Xiao; Heinrich, M.P.; Schnabel, J.A.; Jenkinson, M.; Lorenz, C.; Modat, M.; McClelland, J.R.; Ourselin, S.; Muenzing, S.E.A.; Viergever, M.A.; Nigris, De D.; Collins, D.L.; Arbel, T.; Peroni, M.; Li, R.; Sharp, G.; Schmidt-Richberg, A.; Ehrhardt, J.; Werner, R.; Smeets, D.; Loeckx, D.; Song, G.; Tustison, N.; Avants, B.; Gee, J.C.; Staring, M.; Klein, S.; Stoel, B.C.; Urschler, M.; Werlberger, M.; Vandemeulebroucke, J.; Rit, S.; Sarrut, D.; Pluim, J.P.W.

    2011-01-01

    EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intrapatient thoracic CT image pairs. Evaluation of nonrigid registration techniques is a nontrivial task. This

  18. Markerless laser registration in image-guided oral and maxillofacial surgery.

    Science.gov (United States)

    Marmulla, Rüdiger; Lüth, Tim; Mühling, Joachim; Hassfeld, Stefan

    2004-07-01

    The use of registration markers in computer-assisted surgery is combined with high logistic costs and efforts. Markerless patient registration using laser scan surface registration techniques is a new challenging method. The present study was performed to evaluate the clinical accuracy in finding defined target points within the surgical site after markerless patient registration in image-guided oral and maxillofacial surgery. Twenty consecutive patients with different cranial diseases were scheduled for computer-assisted surgery. Data set alignment between the surgical site and the computed tomography (CT) data set was performed by markerless laser scan surface registration of the patient's face. Intraoral rigidly attached registration markers were used as target points, which had to be detected by an infrared pointer. The Surgical Segment Navigator SSN++ has been used for all procedures. SSN++ is an investigative product based on the SSN system that had previously been developed by the presenting authors with the support of Carl Zeiss (Oberkochen, Germany). SSN++ is connected to a Polaris infrared camera (Northern Digital, Waterloo, Ontario, Canada) and to a Minolta VI 900 3D digitizer (Tokyo, Japan) for high-resolution laser scanning. Minimal differences in shape between the laser scan surface and the surface generated from the CT data set could be detected. Nevertheless, high-resolution laser scan of the skin surface allows for a precise patient registration (mean deviation 1.1 mm, maximum deviation 1.8 mm). Radiation load, logistic costs, and efforts arising from the planning of computer-assisted surgery of the head can be reduced because native (markerless) CT data sets can be used for laser scan-based surface registration.

  19. On developing B-spline registration algorithms for multi-core processors

    International Nuclear Information System (INIS)

    Shackleford, J A; Kandasamy, N; Sharp, G C

    2010-01-01

    Spline-based deformable registration methods are quite popular within the medical-imaging community due to their flexibility and robustness. However, they require a large amount of computing time to obtain adequate results. This paper makes two contributions towards accelerating B-spline-based registration. First, we propose a grid-alignment scheme and associated data structures that greatly reduce the complexity of the registration algorithm. Based on this grid-alignment scheme, we then develop highly data parallel designs for B-spline registration within the stream-processing model, suitable for implementation on multi-core processors such as graphics processing units (GPUs). Particular attention is focused on an optimal method for performing analytic gradient computations in a data parallel fashion. CPU and GPU versions are validated for execution time and registration quality. Performance results on large images show that our GPU algorithm achieves a speedup of 15 times over the single-threaded CPU implementation whereas our multi-core CPU algorithm achieves a speedup of 8 times over the single-threaded implementation. The CPU and GPU versions achieve near-identical registration quality in terms of RMS differences between the generated vector fields.

  20. On removing interpolation and resampling artifacts in rigid image registration.

    Science.gov (United States)

    Aganj, Iman; Yeo, Boon Thye Thomas; Sabuncu, Mert R; Fischl, Bruce

    2013-02-01

    We show that image registration using conventional interpolation and summation approximations of continuous integrals can generally fail because of resampling artifacts. These artifacts negatively affect the accuracy of registration by producing local optima, altering the gradient, shifting the global optimum, and making rigid registration asymmetric. In this paper, after an extensive literature review, we demonstrate the causes of the artifacts by comparing inclusion and avoidance of resampling analytically. We show the sum-of-squared-differences cost function formulated as an integral to be more accurate compared with its traditional sum form in a simple case of image registration. We then discuss aliasing that occurs in rotation, which is due to the fact that an image represented in the Cartesian grid is sampled with different rates in different directions, and propose the use of oscillatory isotropic interpolation kernels, which allow better recovery of true global optima by overcoming this type of aliasing. Through our experiments on brain, fingerprint, and white noise images, we illustrate the superior performance of the integral registration cost function in both the Cartesian and spherical coordinates, and also validate the introduced radial interpolation kernel by demonstrating the improvement in registration.

  1. Robust non-rigid point set registration using student's-t mixture model.

    Directory of Open Access Journals (Sweden)

    Zhiyong Zhou

    Full Text Available The Student's-t mixture model, which is heavily tailed and more robust than the Gaussian mixture model, has recently received great attention on image processing. In this paper, we propose a robust non-rigid point set registration algorithm using the Student's-t mixture model. Specifically, first, we consider the alignment of two point sets as a probability density estimation problem and treat one point set as Student's-t mixture model centroids. Then, we fit the Student's-t mixture model centroids to the other point set which is treated as data. Finally, we get the closed-form solutions of registration parameters, leading to a computationally efficient registration algorithm. The proposed algorithm is especially effective for addressing the non-rigid point set registration problem when significant amounts of noise and outliers are present. Moreover, less registration parameters have to be set manually for our algorithm compared to the popular coherent points drift (CPD algorithm. We have compared our algorithm with other state-of-the-art registration algorithms on both 2D and 3D data with noise and outliers, where our non-rigid registration algorithm showed accurate results and outperformed the other algorithms.

  2. Deep Adaptive Log-Demons: Diffeomorphic Image Registration with Very Large Deformations

    Directory of Open Access Journals (Sweden)

    Liya Zhao

    2015-01-01

    Full Text Available This paper proposes a new framework for capturing large and complex deformation in image registration. Traditionally, this challenging problem relies firstly on a preregistration, usually an affine matrix containing rotation, scale, and translation and afterwards on a nonrigid transformation. According to preregistration, the directly calculated affine matrix, which is obtained by limited pixel information, may misregistrate when large biases exist, thus misleading following registration subversively. To address this problem, for two-dimensional (2D images, the two-layer deep adaptive registration framework proposed in this paper firstly accurately classifies the rotation parameter through multilayer convolutional neural networks (CNNs and then identifies scale and translation parameters separately. For three-dimensional (3D images, affine matrix is located through feature correspondences by a triplanar 2D CNNs. Then deformation removal is done iteratively through preregistration and demons registration. By comparison with the state-of-the-art registration framework, our method gains more accurate registration results on both synthetic and real datasets. Besides, principal component analysis (PCA is combined with correlation like Pearson and Spearman to form new similarity standards in 2D and 3D registration. Experiment results also show faster convergence speed.

  3. Image registration in gastric emptying studies

    International Nuclear Information System (INIS)

    Shuter, B.; Cooper, R.G.

    1998-01-01

    Full text: We have previously shown that image registration, based upon a two-dimensional cross-correlation (CC) of logarithmic Laplacian images (LLI), corrected motion in biliary studies in up to 90% of cases with minimal artifact. We have now applied the same technique to gastric emptying studies (GES). GES were acquired on an LFOV gamma camera over a two-hour period as 20-26 pairs of anterior-posterior frames (30 second duration and 64 x 64 matrix) for both solid and liquid components. All images were manually registered so that the solid contents of the stomach lay within an operator-drawn ROI. The anterior images of the solid component for 30 randomly selected patients were subjected to further image registration using CC of LLI, CC of raw images (Rl) (a common approach to image registration) and CC of Laplacian images (Ll). All images were aligned to the third image of the study, on which an ROI was drawn to outline the stomach. The number of images in which stomach counts appeared outside this ROI were tallied, in the original and all re-registered studies. Maximum displacements in X/Y position between images of studies registered by the LLI and Rl methods were also computed to directly compare positional accuracy. Stomachs partially exceeded the limits of the ROI in 27, 9, 53 and 54 frames (total of 710) in the original, LLI, Rl and Ll studies respectively. There were 4, 1, 6 and 7 studies with misregistered stomachs on more than 2 frames. Frames in seven Rl studies differed from the LLI studies in ) X/Y position by 3 pixels or more. Cross-correlation using LLI was the only method which improved upon the original manual registration. The Rl and Ll methods increased the number of misregistered frames. We conclude that in gastric emptying studies, as in biliary studies, object tracking by CC of LLI is the method of choice for image registration

  4. Robust image registration for multiple exposure high dynamic range image synthesis

    Science.gov (United States)

    Yao, Susu

    2011-03-01

    Image registration is an important preprocessing technique in high dynamic range (HDR) image synthesis. This paper proposed a robust image registration method for aligning a group of low dynamic range images (LDR) that are captured with different exposure times. Illumination change and photometric distortion between two images would result in inaccurate registration. We propose to transform intensity image data into phase congruency to eliminate the effect of the changes in image brightness and use phase cross correlation in the Fourier transform domain to perform image registration. Considering the presence of non-overlapped regions due to photometric distortion, evolutionary programming is applied to search for the accurate translation parameters so that the accuracy of registration is able to be achieved at a hundredth of a pixel level. The proposed algorithm works well for under and over-exposed image registration. It has been applied to align LDR images for synthesizing high quality HDR images..

  5. Multimodality Registration without a Dedicated Multimodality Scanner

    Directory of Open Access Journals (Sweden)

    Bradley J. Beattie

    2007-03-01

    Full Text Available Multimodality scanners that allow the acquisition of both functional and structural image sets on a single system have recently become available for animal research use. Although the resultant registered functional/structural image sets can greatly enhance the interpretability of the functional data, the cost of multimodality systems can be prohibitive, and they are often limited to two modalities, which generally do not include magnetic resonance imaging. Using a thin plastic wrap to immobilize and fix a mouse or other small animal atop a removable bed, we are able to calculate registrations between all combinations of four different small animal imaging scanners (positron emission tomography, single-photon emission computed tomography, magnetic resonance, and computed tomography [CT] at our disposal, effectively equivalent to a quadruple-modality scanner. A comparison of serially acquired CT images, with intervening acquisitions on other scanners, demonstrates the ability of the proposed procedures to maintain the rigidity of an anesthetized mouse during transport between scanners. Movement of the bony structures of the mouse was estimated to be 0.62 mm. Soft tissue movement was predominantly the result of the filling (or emptying of the urinary bladder and thus largely constrained to this region. Phantom studies estimate the registration errors for all registration types to be less than 0.5 mm. Functional images using tracers targeted to known structures verify the accuracy of the functional to structural registrations. The procedures are easy to perform and produce robust and accurate results that rival those of dedicated multimodality scanners, but with more flexible registration combinations and while avoiding the expense and redundancy of multimodality systems.

  6. Comparison of manual and automatic MR‐CT registration for radiotherapy of prostate cancer

    Science.gov (United States)

    Carl, Jesper; Østergaard, Lasse Riis

    2016-01-01

    In image‐guided radiotherapy (IGRT) of prostate cancer, delineation of the clinical target volume (CTV) often relies on magnetic resonance (MR) because of its good soft‐tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR‐CT registration of the prostate has previously been developed using a voxel property‐based registration as an alternative to a manual landmark‐based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni‐Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80 mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration. PACS number(s): 87.57.nj, 87.61.‐c, 87.57.Q‐, 87.56.J‐ PMID:27167285

  7. 48 CFR 52.232-33 - Payment by Electronic Funds Transfer-Central Contractor Registration.

    Science.gov (United States)

    2010-10-01

    ... Government under this contract shall be made by electronic funds transfer (EFT), except as provided in... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Payment by Electronic... CONTRACT CLAUSES Text of Provisions and Clauses 52.232-33 Payment by Electronic Funds Transfer—Central...

  8. PCANet-Based Structural Representation for Nonrigid Multimodal Medical Image Registration

    Directory of Open Access Journals (Sweden)

    Xingxing Zhu

    2018-05-01

    Full Text Available Nonrigid multimodal image registration remains a challenging task in medical image processing and analysis. The structural representation (SR-based registration methods have attracted much attention recently. However, the existing SR methods cannot provide satisfactory registration accuracy due to the utilization of hand-designed features for structural representation. To address this problem, the structural representation method based on the improved version of the simple deep learning network named PCANet is proposed for medical image registration. In the proposed method, PCANet is firstly trained on numerous medical images to learn convolution kernels for this network. Then, a pair of input medical images to be registered is processed by the learned PCANet. The features extracted by various layers in the PCANet are fused to produce multilevel features. The structural representation images are constructed for two input images based on nonlinear transformation of these multilevel features. The Euclidean distance between structural representation images is calculated and used as the similarity metrics. The objective function defined by the similarity metrics is optimized by L-BFGS method to obtain parameters of the free-form deformation (FFD model. Extensive experiments on simulated and real multimodal image datasets show that compared with the state-of-the-art registration methods, such as modality-independent neighborhood descriptor (MIND, normalized mutual information (NMI, Weber local descriptor (WLD, and the sum of squared differences on entropy images (ESSD, the proposed method provides better registration performance in terms of target registration error (TRE and subjective human vision.

  9. Coarse Point Cloud Registration by Egi Matching of Voxel Clusters

    Science.gov (United States)

    Wang, Jinhu; Lindenbergh, Roderik; Shen, Yueqian; Menenti, Massimo

    2016-06-01

    Laser scanning samples the surface geometry of objects efficiently and records versatile information as point clouds. However, often more scans are required to fully cover a scene. Therefore, a registration step is required that transforms the different scans into a common coordinate system. The registration of point clouds is usually conducted in two steps, i.e. coarse registration followed by fine registration. In this study an automatic marker-free coarse registration method for pair-wise scans is presented. First the two input point clouds are re-sampled as voxels and dimensionality features of the voxels are determined by principal component analysis (PCA). Then voxel cells with the same dimensionality are clustered. Next, the Extended Gaussian Image (EGI) descriptor of those voxel clusters are constructed using significant eigenvectors of each voxel in the cluster. Correspondences between clusters in source and target data are obtained according to the similarity between their EGI descriptors. The random sampling consensus (RANSAC) algorithm is employed to remove outlying correspondences until a coarse alignment is obtained. If necessary, a fine registration is performed in a final step. This new method is illustrated on scan data sampling two indoor scenarios. The results of the tests are evaluated by computing the point to point distance between the two input point clouds. The presented two tests resulted in mean distances of 7.6 mm and 9.5 mm respectively, which are adequate for fine registration.

  10. Fractional Regularization Term for Variational Image Registration

    Directory of Open Access Journals (Sweden)

    Rafael Verdú-Monedero

    2009-01-01

    Full Text Available Image registration is a widely used task of image analysis with applications in many fields. Its classical formulation and current improvements are given in the spatial domain. In this paper a regularization term based on fractional order derivatives is formulated. This term is defined and implemented in the frequency domain by translating the energy functional into the frequency domain and obtaining the Euler-Lagrange equations which minimize it. The new regularization term leads to a simple formulation and design, being applicable to higher dimensions by using the corresponding multidimensional Fourier transform. The proposed regularization term allows for a real gradual transition from a diffusion registration to a curvature registration which is best suited to some applications and it is not possible in the spatial domain. Results with 3D actual images show the validity of this approach.

  11. Registration of eye reflection and scene images using an aspherical eye model.

    Science.gov (United States)

    Nakazawa, Atsushi; Nitschke, Christian; Nishida, Toyoaki

    2016-11-01

    This paper introduces an image registration algorithm between an eye reflection and a scene image. Although there are currently a large number of image registration algorithms, this task remains difficult due to nonlinear distortions at the eye surface and large amounts of noise, such as iris texture, eyelids, eyelashes, and their shadows. To overcome this issue, we developed an image registration method combining an aspherical eye model that simulates nonlinear distortions considering eye geometry and a two-step iterative registration strategy that obtains dense correspondence of the feature points to achieve accurate image registrations for the entire image region. We obtained a database of eye reflection and scene images featuring four subjects in indoor and outdoor scenes and compared the registration performance with different asphericity conditions. Results showed that the proposed approach can perform accurate registration with an average accuracy of 1.05 deg by using the aspherical cornea model. This work is relevant for eye image analysis in general, enabling novel applications and scenarios.

  12. Characteristics, availability and uses of vital registration and other mortality data sources in post-democracy South Africa

    Science.gov (United States)

    Joubert, Jané; Rao, Chalapati; Bradshaw, Debbie; Dorrington, Rob E.; Vos, Theo; Lopez, Alan D.

    2012-01-01

    The value of good-quality mortality data for public health is widely acknowledged. While effective civil registration systems remains the ‘gold standard’ source for continuous mortality measurement, less than 25% of deaths are registered in most African countries. Alternative data collection systems can provide mortality data to complement those from civil registration, given an understanding of data source characteristics and data quality. We aim to document mortality data sources in post-democracy South Africa; to report on availability, limitations, strengths, and possible complementary uses of the data; and to make recommendations for improved data for mortality measurement. Civil registration and alternative mortality data collection systems, data availability, and complementary uses were assessed by reviewing blank questionnaires, death notification forms, death data capture sheets, and patient cards; legislation; electronic data archives and databases; and related information in scientific journals, research reports, statistical releases, government reports and books. Recent transformation has enhanced civil registration and official mortality data availability. Additionally, a range of mortality data items are available in three population censuses, three demographic surveillance systems, and a number of national surveys, mortality audits, and disease notification programmes. Child and adult mortality items were found in all national data sources, and maternal mortality items in most. Detailed cause-of-death data are available from civil registration and demographic surveillance. In a continent often reported as lacking the basic data to infer levels, patterns and trends of mortality, there is evidence of substantial improvement in South Africa in the availability of data for mortality assessment. Mortality data sources are many and varied, providing opportunity for comparing results and improved public health planning. However, more can and must be

  13. The Iraqi civil registration system and the test of political upheaval

    Directory of Open Access Journals (Sweden)

    Sulaiman Bah

    2014-04-01

    Full Text Available An in-depth situation analysis was carried out on the Iraqi civil registration system in 2011, years after the end of the military operation of 2003. The study was done using a combination of methods, including interviews with key role players in the Iraqi civil registration system, observation, study of documents, triangulation, and gap analysis. The study found the civil registration system in Iraq to be largely intact and functional, in spite of the wars experienced in Iraq over the past three decades. Given that civil registration systems generally get destroyed through wars, the paper discusses the reasons for the resilience in the Iraqi civil registration system and draws lessons from them.

  14. Technical Training: ELEC-2005 - Electronics in High Energy Physics: Summer Term (May 2005)

    CERN Multimedia

    Davide Vitè

    2005-01-01

    ELEC-2005 is a new course series on modern electronics, given by CERN physicists and engineers within the framework of the 2005 Technical Training Programme. It is designed for people who are not electronics specialists, for example physicists, engineers and technicians working at or visiting the laboratory, who use or will use electronics in their present or future activities, in particular in the context of the LHC accelerator and experiments. The next ELEC-2005 Summer Term, System electronics for physics: Issues, is now open for online registration, and will start on May 10th. Lectures will take place on Tuesdays and Thursdays, from 10h00 to 12h30. The course will be in English, with questions and answers also possible in French. Separate registration to each Term is required: attendance costs will be of 10.- CHF per lecture (Summer Term: 70.- CHF). If you are interested in attending, please discuss with your supervisor and/or your DTO, and apply electronically via EDH. Participation to all sessions in a...

  15. An atlas-based multimodal registration method for 2D images with discrepancy structures.

    Science.gov (United States)

    Lv, Wenchao; Chen, Houjin; Peng, Yahui; Li, Yanfeng; Li, Jupeng

    2018-06-04

    An atlas-based multimodal registration method for 2-dimension images with discrepancy structures was proposed in this paper. Atlas was utilized for complementing the discrepancy structure information in multimodal medical images. The scheme includes three steps: floating image to atlas registration, atlas to reference image registration, and field-based deformation. To evaluate the performance, a frame model, a brain model, and clinical images were employed in registration experiments. We measured the registration performance by the squared sum of intensity differences. Results indicate that this method is robust and performs better than the direct registration for multimodal images with discrepancy structures. We conclude that the proposed method is suitable for multimodal images with discrepancy structures. Graphical Abstract An Atlas-based multimodal registration method schematic diagram.

  16. 75 FR 55671 - Financial Assistance Use of Universal Identifier and Central Contractor Registration

    Science.gov (United States)

    2010-09-14

    ... of Universal Identifier and Central Contractor Registration AGENCY: Office of Federal Financial...) numbers and maintain current registrations in the Central Contractor Registration (CCR) database. An... CONTRACTOR REGISTRATION Sec. Subpart A--General 25.100 Purposes of this part. 25.105 Types of awards to which...

  17. Block assembly for global registration of building scans

    KAUST Repository

    Yan, Feilong; Nan, Liangliang; Wonka, Peter

    2016-01-01

    We propose a framework for global registration of building scans. The first contribution of our work is to detect and use portals (e.g., doors and windows) to improve the local registration between two scans. Our second contribution is an optimization based on a linear integer programming formulation. We abstract each scan as a block and model the blocks registration as an optimization problem that aims at maximizing the overall matching score of the entire scene. We propose an efficient solution to this optimization problem by iteratively detecting and adding local constraints. We demonstrate the effectiveness of the proposed method on buildings of various styles and that our approach is superior to the current state of the art.

  18. Block assembly for global registration of building scans

    KAUST Repository

    Yan, Feilong

    2016-11-11

    We propose a framework for global registration of building scans. The first contribution of our work is to detect and use portals (e.g., doors and windows) to improve the local registration between two scans. Our second contribution is an optimization based on a linear integer programming formulation. We abstract each scan as a block and model the blocks registration as an optimization problem that aims at maximizing the overall matching score of the entire scene. We propose an efficient solution to this optimization problem by iteratively detecting and adding local constraints. We demonstrate the effectiveness of the proposed method on buildings of various styles and that our approach is superior to the current state of the art.

  19. Error estimation of deformable image registration of pulmonary CT scans using convolutional neural networks.

    Science.gov (United States)

    Eppenhof, Koen A J; Pluim, Josien P W

    2018-04-01

    Error estimation in nonlinear medical image registration is a nontrivial problem that is important for validation of registration methods. We propose a supervised method for estimation of registration errors in nonlinear registration of three-dimensional (3-D) images. The method is based on a 3-D convolutional neural network that learns to estimate registration errors from a pair of image patches. By applying the network to patches centered around every voxel, we construct registration error maps. The network is trained using a set of representative images that have been synthetically transformed to construct a set of image pairs with known deformations. The method is evaluated on deformable registrations of inhale-exhale pairs of thoracic CT scans. Using ground truth target registration errors on manually annotated landmarks, we evaluate the method's ability to estimate local registration errors. Estimation of full domain error maps is evaluated using a gold standard approach. The two evaluation approaches show that we can train the network to robustly estimate registration errors in a predetermined range, with subvoxel accuracy. We achieved a root-mean-square deviation of 0.51 mm from gold standard registration errors and of 0.66 mm from ground truth landmark registration errors.

  20. 75 FR 8339 - Difenzoquat; Product Cancellation Order for Certain Pesticide Registrations

    Science.gov (United States)

    2010-02-24

    ... products identified in Table 1 of Unit II in a manner inconsistent with any of the Provisions for... registrant listed in Table 1 to voluntarily cancel these product registrations. These are the last products... are listed in sequence by registration number in Table 1 of this unit. Table 1. -- Difenzoquat Product...

  1. Practical and conceptual issues of clinical trial registration for Brazilian researchers

    Directory of Open Access Journals (Sweden)

    Carolina Gomes Freitas

    Full Text Available CONTEXT AND OBJECTIVE: Clinical trial registration is a prerequisite for publication in respected scientific journals. Recent Brazilian regulations also require registration of some clinical trials in the Brazilian Clinical Trials Registry (ReBEC but there is little information available about practical issues involved in the registration process. This article discusses the importance of clinical trial registration and the practical issues involved in this process. DESIGN AND SETTING: Descriptive study conducted by researchers within a postgraduate program at a public university in São Paulo, Brazil. METHODS: Information was obtained from clinical trial registry platforms, article reference lists and websites (last search: September 2014 on the following topics: definition of a clinical trial, history, purpose and importance of registry platforms, the information that should be registered and the registration process. RESULTS: Clinical trial registration aims to avoid publication bias and is required by Brazilian journals indexed in LILACS and SciELO and by journals affiliated to the International Committee of Medical Journal Editors (ICMJE. Recent Brazilian regulations require that all clinical trials (phases I to IV involving new drugs to be marketed in this country must be registered in ReBEC. The pros and cons of using different clinical trial registration platforms are discussed. CONCLUSIONS: Clinical trial registration is important and various mechanisms to enforce its implementation now exist. Researchers should take into account national regulations and publication requirements when choosing the platform on which they will register their trial.

  2. Robust feature estimation by non-rigid hierarchical image registration and its application in disparity measurement

    Science.gov (United States)

    Badshah, Amir; Choudhry, Aadil Jaleel; Ullah, Shan

    2017-03-01

    Industries are moving towards automation in order to increase productivity and ensure quality. Variety of electronic and electromagnetic systems are being employed to assist human operator in fast and accurate quality inspection of products. Majority of these systems are equipped with cameras and rely on diverse image processing algorithms. Information is lost in 2D image, therefore acquiring accurate 3D data from 2D images is an open issue. FAST, SURF and SIFT are well-known spatial domain techniques for features extraction and henceforth image registration to find correspondence between images. The efficiency of these methods is measured in terms of the number of perfect matches found. A novel fast and robust technique for stereo-image processing is proposed. It is based on non-rigid registration using modified normalized phase correlation. The proposed method registers two images in hierarchical fashion using quad-tree structure. The registration process works through global to local level resulting in robust matches even in presence of blur and noise. The computed matches can further be utilized to determine disparity and depth for industrial product inspection. The same can be used in driver assistance systems. The preliminary tests on Middlebury dataset produced satisfactory results. The execution time for a 413 x 370 stereo-pair is 500ms approximately on a low cost DSP.

  3. Optimization strategies for ultrasound volume registration

    International Nuclear Information System (INIS)

    Ijaz, Umer Zeeshan; Prager, Richard W; Gee, Andrew H; Treece, Graham M

    2010-01-01

    This paper considers registration of 3D ultrasound volumes acquired in multiple views for display in a single image volume. One way to acquire 3D data is to use a mechanically swept 3D probe. However, the usefulness of these probes is restricted by their limited field of view. This problem can be overcome by attaching a six-degree-of-freedom (DOF) position sensor to the probe, and displaying the information from multiple sweeps in their proper positions. However, an external six-DOF position sensor can be an inconvenience in a clinical setting. The objective of this paper is to propose a hybrid strategy that replaces the sensor with a combination of three-DOF image registration and an unobtrusive inertial sensor for measuring orientation. We examine a range of optimization algorithms and similarity measures for registration and compare them in in vitro and in vivo experiments. We register based on multiple reslice images rather than a whole voxel array. In this paper, we use a large number of reslices for improved reliability at the expense of computational speed. We have found that the Levenberg–Marquardt method is very fast but is not guaranteed to give the correct solution all the time. We conclude that normalized mutual information used in the Nelder–Mead simplex algorithm is potentially suitable for the registration task with an average execution time of around 5 min, in the majority of cases, with two restarts in a C++ implementation on a 3.0 GHz Intel Core 2 Duo CPU machine

  4. Edge-based correlation image registration for multispectral imaging

    Science.gov (United States)

    Nandy, Prabal [Albuquerque, NM

    2009-11-17

    Registration information for images of a common target obtained from a plurality of different spectral bands can be obtained by combining edge detection and phase correlation. The images are edge-filtered, and pairs of the edge-filtered images are then phase correlated to produce phase correlation images. The registration information can be determined based on these phase correlation images.

  5. Drug Establishments Current Registration Site

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Establishments Current Registration Site (DECRS) is a database of current information submitted by drug firms to register establishments (facilities) which...

  6. Summer Camp July 2017 - Registration

    CERN Multimedia

    EVE et École

    2017-01-01

    The CERN Staff Association’s Summer Camp will be open for children from 4 to 6 years old during four weeks, from 3 to 28 July. Registration is offered on a weekly basis for 450 CHF, lunch included. This year, the various activities will revolve around the theme of the Four Elements. Registration opened on 20 March 2017 for children currently attending the EVE and School of the Association. It will be open from 3 April for children of CERN Members of Personnel, and starting from 24 April for all other children. The general conditions are available on the website of the EVE and School of CERN Staff Association: http://nurseryschool.web.cern.ch. For further questions, please contact us by email at Summer.Camp@cern.ch.

  7. Computing homography with RANSAC algorithm: a novel method of registration

    Science.gov (United States)

    Li, Xiaowei; Liu, Yue; Wang, Yongtian; Yan, Dayuan

    2005-02-01

    An AR (Augmented Reality) system can integrate computer-generated objects with the image sequences of real world scenes in either an off-line or a real-time way. Registration, or camera pose estimation, is one of the key techniques to determine its performance. The registration methods can be classified as model-based and move-matching. The former approach can accomplish relatively accurate registration results, but it requires the precise model of the scene, which is hard to be obtained. The latter approach carries out registration by computing the ego-motion of the camera. Because it does not require the prior-knowledge of the scene, its registration results sometimes turn out to be less accurate. When the model defined is as simple as a plane, a mixed method is introduced to take advantages of the virtues of the two methods mentioned above. Although unexpected objects often occlude this plane in an AR system, one can still try to detect corresponding points with a contract-expand method, while this will import erroneous correspondences. Computing homography with RANSAC algorithm is used to overcome such shortcomings. Using the robustly estimated homography resulted from RANSAC, the camera projective matrix can be recovered and thus registration is accomplished even when the markers are lost in the scene.

  8. A systematic review of comparisons between protocols or registrations and full reports in primary biomedical research

    Directory of Open Access Journals (Sweden)

    Guowei Li

    2018-01-01

    Full Text Available Abstract Background Prospective study protocols and registrations can play a significant role in reducing incomplete or selective reporting of primary biomedical research, because they are pre-specified blueprints which are available for the evaluation of, and comparison with, full reports. However, inconsistencies between protocols or registrations and full reports have been frequently documented. In this systematic review, which forms part of our series on the state of reporting of primary biomedical, we aimed to survey the existing evidence of inconsistencies between protocols or registrations (i.e., what was planned to be done and/or what was actually done and full reports (i.e., what was reported in the literature; this was based on findings from systematic reviews and surveys in the literature. Methods Electronic databases, including CINAHL, MEDLINE, Web of Science, and EMBASE, were searched to identify eligible surveys and systematic reviews. Our primary outcome was the level of inconsistency (expressed as a percentage, with higher percentages indicating greater inconsistency between protocols or registration and full reports. We summarized the findings from the included systematic reviews and surveys qualitatively. Results There were 37 studies (33 surveys and 4 systematic reviews included in our analyses. Most studies (n = 36 compared protocols or registrations with full reports in clinical trials, while a single survey focused on primary studies of clinical trials and observational research. High inconsistency levels were found in outcome reporting (ranging from 14% to 100%, subgroup reporting (from 12% to 100%, statistical analyses (from 9% to 47%, and other measure comparisons. Some factors, such as outcomes with significant results, sponsorship, type of outcome and disease speciality were reported to be significantly related to inconsistent reporting. Conclusions We found that inconsistent reporting between protocols or

  9. Alternative face models for 3D face registration

    Science.gov (United States)

    Salah, Albert Ali; Alyüz, Neşe; Akarun, Lale

    2007-01-01

    3D has become an important modality for face biometrics. The accuracy of a 3D face recognition system depends on a correct registration that aligns the facial surfaces and makes a comparison possible. The best results obtained so far use a one-to-all registration approach, which means each new facial surface is registered to all faces in the gallery, at a great computational cost. We explore the approach of registering the new facial surface to an average face model (AFM), which automatically establishes correspondence to the pre-registered gallery faces. Going one step further, we propose that using a couple of well-selected AFMs can trade-off computation time with accuracy. Drawing on cognitive justifications, we propose to employ category-specific alternative average face models for registration, which is shown to increase the accuracy of the subsequent recognition. We inspect thin-plate spline (TPS) and iterative closest point (ICP) based registration schemes under realistic assumptions on manual or automatic landmark detection prior to registration. We evaluate several approaches for the coarse initialization of ICP. We propose a new algorithm for constructing an AFM, and show that it works better than a recent approach. Finally, we perform simulations with multiple AFMs that correspond to different clusters in the face shape space and compare these with gender and morphology based groupings. We report our results on the FRGC 3D face database.

  10. A comparison of publicly available linear MRI stereotaxic registration techniques.

    Science.gov (United States)

    Dadar, Mahsa; Fonov, Vladimir S; Collins, D Louis

    2018-07-01

    Linear registration to a standard space is one of the major steps in processing and analyzing magnetic resonance images (MRIs) of the brain. Here we present an overview of linear stereotaxic MRI registration and compare the performance of 5 publicly available and extensively used linear registration techniques in medical image analysis. A set of 9693 T1-weighted MR images were obtained for testing from 4 datasets: ADNI, PREVENT-AD, PPMI, and HCP, two of which have multi-center and multi-scanner data and three of which have longitudinal data. Each individual native image was linearly registered to the MNI ICBM152 average template using five versions of MRITOTAL from MINC tools, FLIRT from FSL, two versions of Elastix, spm_affreg from SPM, and ANTs linear registration techniques. Quality control (QC) images were generated from the registered volumes and viewed by an expert rater to assess the quality of the registrations. The QC image contained 60 sub-images (20 of each of axial, sagittal, and coronal views at different levels throughout the brain) overlaid with contours of the ICBM152 template, enabling the expert rater to label the registration as acceptable or unacceptable. The performance of the registration techniques was then compared across different datasets. In addition, the effect of image noise, intensity non-uniformity, age, head size, and atrophy on the performance of the techniques was investigated by comparing differences between age, scaling factor, ventricle volume, brain volume, and white matter hyperintensity (WMH) volumes between passed and failed cases for each method. The average registration failure rate among all datasets was 27.41%, 27.14%, 12.74%, 13.03%, 0.44% for the five versions of MRITOTAL techniques, 8.87% for ANTs, 11.11% for FSL, 12.35% for Elastix Affine, 24.40% for Elastix Similarity, and 30.66% for SPM. There were significant effects of signal to noise ratio, image intensity non-uniformity estimates, as well as age, head size, and

  11. Comparison of manual vs. automated multimodality (CT-MRI) image registration for brain tumors

    International Nuclear Information System (INIS)

    Sarkar, Abhirup; Santiago, Roberto J.; Smith, Ryan; Kassaee, Alireza

    2005-01-01

    Computed tomgoraphy-magnetic resonance imaging (CT-MRI) registrations are routinely used for target-volume delineation of brain tumors. We clinically use 2 software packages based on manual operation and 1 automated package with 2 different algorithms: chamfer matching using bony structures, and mutual information using intensity patterns. In all registration algorithms, a minimum of 3 pairs of identical anatomical and preferably noncoplanar landmarks is used on each of the 2 image sets. In manual registration, the program registers these points and links the image sets using a 3-dimensional (3D) transformation. In automated registration, the 3 landmarks are used as an initial starting point and further processing is done to complete the registration. Using our registration packages, registration of CT and MRI was performed on 10 patients. We scored the results of each registration set based on the amount of time spent, the accuracy reported by the software, and a final evaluation. We evaluated each software program by measuring the residual error between 'matched' points on the right and left globes and the posterior fossa for fused image slices. In general, manual registration showed higher misalignment between corresponding points compared to automated registration using intensity matching. This error had no directional dependence and was, most of the time, larger for a larger structure in both registration techniques. Automated algorithm based on intensity matching also gave the best results in terms of registration accuracy, irrespective of whether or not the initial landmarks were chosen carefully, when compared to that done using bone matching algorithm. Intensity-matching algorithm required the least amount of user-time and provided better accuracy

  12. S-HAMMER: hierarchical attribute-guided, symmetric diffeomorphic registration for MR brain images.

    Science.gov (United States)

    Wu, Guorong; Kim, Minjeong; Wang, Qian; Shen, Dinggang

    2014-03-01

    Deformable registration has been widely used in neuroscience studies for spatial normalization of brain images onto the standard space. Because of possible large anatomical differences across different individual brains, registration performance could be limited when trying to estimate a single directed deformation pathway, i.e., either from template to subject or from subject to template. Symmetric image registration, however, offers an effective way to simultaneously deform template and subject images toward each other until they meet at the middle point. Although some intensity-based registration algorithms have nicely incorporated this concept of symmetric deformation, the pointwise intensity matching between two images may not necessarily imply the matching of correct anatomical correspondences. Based on HAMMER registration algorithm (Shen and Davatzikos, [2002]: IEEE Trans Med Imaging 21:1421-1439), we integrate the strategies of hierarchical attribute matching and symmetric diffeomorphic deformation to build a new symmetric-diffeomorphic HAMMER registration algorithm, called as S-HAMMER. The performance of S-HAMMER has been extensively compared with 14 state-of-the-art nonrigid registration algorithms evaluated in (Klein et al., [2009]: NeuroImage 46:786-802) by using real brain images in LPBA40, IBSR18, CUMC12, and MGH10 datasets. In addition, the registration performance of S-HAMMER, by comparison with other methods, is also demonstrated on both elderly MR brain images (>70 years old) and the simulated brain images with ground-truth deformation fields. In all experiments, our proposed method achieves the best registration performance over all other registration methods, indicating the high applicability of our method in future neuroscience and clinical applications. Copyright © 2013 Wiley Periodicals, Inc.

  13. Registration of TLS and MLS Point Cloud Combining Genetic Algorithm with ICP

    Directory of Open Access Journals (Sweden)

    YAN Li

    2018-04-01

    Full Text Available Large scene point cloud can be quickly acquired by mobile laser scanning (MLS technology,which needs to be supplemented by terrestrial laser scanning (TLS point cloud because of limited field of view and occlusion.MLS and TLS point cloud are located in geodetic coordinate system and local coordinate system respectively.This paper proposes an automatic registration method combined genetic algorithm (GA and iterative closed point ICP to achieve a uniform coordinate reference frame.The local optimizer is utilized in ICP.The efficiency of ICP is higher than that of GA registration,but it depends on a initial solution.GA is a global optimizer,but it's inefficient.The combining strategy is that ICP is enabled to complete the registration when the GA tends to local search.The rough position measured by a built-in GPS of a terrestrial laser scanner is used in the GA registration to limit its optimizing search space.To improve the GA registration accuracy,a maximum registration model called normalized sum of matching scores (NSMS is presented.The results for measured data show that the NSMS model is effective,the root mean square error (RMSE of GA registration is 1~5 cm and the registration efficiency can be improved by about 50% combining GA with ICP.

  14. Automated dental implantation using image-guided robotics: registration results.

    Science.gov (United States)

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  15. 76 FR 61563 - Voluntary Surrender of Certificate of Registration

    Science.gov (United States)

    2011-10-05

    ... existence, or discontinues business or professional practice * * *.'' 21 CFR 1301.52(a) and 1309.62(a... Administration, if and when such person dies, ceases legal existence, discontinues business or professional practice, or surrenders a registration. Any registrant who ceases legal existence or discontinues business...

  16. 75 FR 32140 - Voluntary Surrender of Certificate of Registration

    Science.gov (United States)

    2010-06-07

    ... existence, or discontinues business or professional practice * * *'' 21 CFR 1301.52(a) and 1309.62(a). Under... Administration, if and when such person dies, ceases legal existence, discontinues business or professional practice, or surrenders a registration. Any registrant who ceases legal existence or discontinues business...

  17. Improving AR tracking and registration with markerless technology

    OpenAIRE

    Shi, Lei

    2017-01-01

    This study is performed with two mai n goals in mind. The first goal is to understand the Augmented Reality technology and its mainly tracking and registration technology , the second one is find a way to improve the registration and tracking accuracy . T he project is graphic digital compass designed for android devices based on these mainly technology . It can obtain t...

  18. Multi-band Image Registration Method Based on Fourier Transform

    Institute of Scientific and Technical Information of China (English)

    庹红娅; 刘允才

    2004-01-01

    This paper presented a registration method based on Fourier transform for multi-band images which is involved in translation and small rotation. Although different band images differ a lot in the intensity and features,they contain certain common information which we can exploit. A model was given that the multi-band images have linear correlations under the least-square sense. It is proved that the coefficients have no effect on the registration progress if two images have linear correlations. Finally, the steps of the registration method were proposed. The experiments show that the model is reasonable and the results are satisfying.

  19. Quantifying brain development in early childhood using segmentation and registration

    Science.gov (United States)

    Aljabar, P.; Bhatia, K. K.; Murgasova, M.; Hajnal, J. V.; Boardman, J. P.; Srinivasan, L.; Rutherford, M. A.; Dyet, L. E.; Edwards, A. D.; Rueckert, D.

    2007-03-01

    In this work we obtain estimates of tissue growth using longitudinal data comprising MR brain images of 25 preterm children scanned at one and two years. The growth estimates are obtained using segmentation and registration based methods. The segmentation approach used an expectation maximisation (EM) method to classify tissue types and the registration approach used tensor based morphometry (TBM) applied to a free form deformation (FFD) model. The two methods show very good agreement indicating that the registration and segmentation approaches can be used interchangeably. The advantage of the registration based method, however, is that it can provide more local estimates of tissue growth. This is the first longitudinal study of growth in early childhood, previous longitudinal studies have focused on later periods during childhood.

  20. Electronic Human Resources Management (e-HRM Adoption Studies: Past and Future Research

    Directory of Open Access Journals (Sweden)

    Winarto Winarto

    2018-05-01

    Full Text Available Electronic human resource management (e-HRM systems become more widely used by profit and non-profit organization. However, the field currently lacks sound theoretical frameworks that can be useful in addressing a key issue concerning the implementation of e-HRM systems, in particular to obtain a better understanding of the factors influencing the adoption of e-HRM systems. The objective of this paper is to provide a foundation towards the development of a theoretical framework for the implementation of e-HRM systems and develop a conceptual model that would reflect the nature of e-HRM systems’ adoption through systematic literature review. Adopting Crossan and Apaydin’s procedure of systematic review, this paper investigated 21 empirical papers of electronics human resources management, then categorized them into 4 characteristics which influence the adoption; System and technology characteristics; Organizational characteristics; User/individual characteristics, and Environmental and contextual characteristics. Finally, the e-HRM adoption research framework is drawn and based on the framework; avenues for future research are discussed.   Bahasa Indonesia Abstrak: Manajemen sumber daya manusia elektronik (selanjutnya disebut dengan e-HRM semakin banyak digunakan oleh organisasi profit dan nonprofit. Namun, bidang dan topik ini belum memiliki kerangka teori yang mapan, yang dapat digunakan untuk menganalisis isu-isu terkait penerapan e-HRM, terutama mengenai faktor-faktor yang mempengaruhi adopsi sistem e-HRM. Tujuan penelitian ini adalah untuk memberikan landasan bagi pengembangan kerangka teoritis untuk implementasi sistem e-HRM dan mengembangkan model konseptual yang akan menggambarkan adopsi sistem e-HRM melalui tinjauan literatur sistematis. Mengadopsi prosedur dan metode Crossan dan Apaydin untuk melakukan telaah literatur secara sistematis, paper ini menyelidiki 21 publikasi empiris manajemen sumber daya manusia elektronik dari 2

  1. Quicksilver: Fast predictive image registration - A deep learning approach.

    Science.gov (United States)

    Yang, Xiao; Kwitt, Roland; Styner, Martin; Niethammer, Marc

    2017-09-01

    This paper introduces Quicksilver, a fast deformable image registration method. Quicksilver registration for image-pairs works by patch-wise prediction of a deformation model based directly on image appearance. A deep encoder-decoder network is used as the prediction model. While the prediction strategy is general, we focus on predictions for the Large Deformation Diffeomorphic Metric Mapping (LDDMM) model. Specifically, we predict the momentum-parameterization of LDDMM, which facilitates a patch-wise prediction strategy while maintaining the theoretical properties of LDDMM, such as guaranteed diffeomorphic mappings for sufficiently strong regularization. We also provide a probabilistic version of our prediction network which can be sampled during the testing time to calculate uncertainties in the predicted deformations. Finally, we introduce a new correction network which greatly increases the prediction accuracy of an already existing prediction network. We show experimental results for uni-modal atlas-to-image as well as uni-/multi-modal image-to-image registrations. These experiments demonstrate that our method accurately predicts registrations obtained by numerical optimization, is very fast, achieves state-of-the-art registration results on four standard validation datasets, and can jointly learn an image similarity measure. Quicksilver is freely available as an open-source software. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. 76 FR 54537 - Swap Data Repositories: Registration Standards, Duties and Core Principles

    Science.gov (United States)

    2011-09-01

    ... Part 49 Swap Data Repositories: Registration Standards, Duties and Core Principles; Final Rule #0;#0...: Registration Standards, Duties and Core Principles AGENCY: Commodity Futures Trading Commission. ACTION: Final... registration requirements, statutory duties, core principles and certain compliance obligations for registered...

  3. A novel Gravity-FREAK feature extraction and Gravity-KLT tracking registration algorithm based on iPhone MEMS mobile sensor in mobile environment.

    Directory of Open Access Journals (Sweden)

    Zhiling Hong

    Full Text Available Based on the traditional Fast Retina Keypoint (FREAK feature description algorithm, this paper proposed a Gravity-FREAK feature description algorithm based on Micro-electromechanical Systems (MEMS sensor to overcome the limited computing performance and memory resources of mobile devices and further improve the reality interaction experience of clients through digital information added to the real world by augmented reality technology. The algorithm takes the gravity projection vector corresponding to the feature point as its feature orientation, which saved the time of calculating the neighborhood gray gradient of each feature point, reduced the cost of calculation and improved the accuracy of feature extraction. In the case of registration method of matching and tracking natural features, the adaptive and generic corner detection based on the Gravity-FREAK matching purification algorithm was used to eliminate abnormal matches, and Gravity Kaneda-Lucas Tracking (KLT algorithm based on MEMS sensor can be used for the tracking registration of the targets and robustness improvement of tracking registration algorithm under mobile environment.

  4. [Medical image elastic registration smoothed by unconstrained optimized thin-plate spline].

    Science.gov (United States)

    Zhang, Yu; Li, Shuxiang; Chen, Wufan; Liu, Zhexing

    2003-12-01

    Elastic registration of medical image is an important subject in medical image processing. Previous work has concentrated on selecting the corresponding landmarks manually and then using thin-plate spline interpolating to gain the elastic transformation. However, the landmarks extraction is always prone to error, which will influence the registration results. Localizing the landmarks manually is also difficult and time-consuming. We the optimization theory to improve the thin-plate spline interpolation, and based on it, used an automatic method to extract the landmarks. Combining these two steps, we have proposed an automatic, exact and robust registration method and have gained satisfactory registration results.

  5. Why and how to make a REACH registration of combustion ash; Moejligheter vid REACH-registrering av energiaskor

    Energy Technology Data Exchange (ETDEWEB)

    Loevgren, Linnea; Wik, Ola

    2009-10-15

    The new chemical regulation, REACH (1997/2006/EC), Registration, Evaluation, Authorization and restriction of Chemicals, took effect the 1st of June 2007. The background to this report was the introduction of REACH and the difficulties to understand the implications for ash. The most important consequence of REACH is that all chemical substances that are manufactured, handled and used above one tonne per annum per legal entity shall be registered according to this regulation. The registration includes specifying the chemical, physical, toxicity and ecotoxicity properties of the substance and risk assessing the identified areas of use. The report describes the use of ash in connection to the waste legislation and its planned end-of-waste-criteria, the chemical legislation and the Construction Products Directive. The target audience of this report is companies producing ashes and having a use or seeing a use for its ash. The report describes how to make a REACH registration of ash independent if a company did or did not pre-register ash during 2008. It describes how to change from one ash registration into another if the pre-registration was done for one type of ash but the company changes opinion during the sameness check, i.e. changing SIEF (Appendix A). Taking part in REACH registration projects during 2009-2010 can be advantageous since knowledge and financing are shared. Ash can be REACH registered also in the future but it is important to know that the registration have to be done prior the production and marketing starts. If ash is consider to be a waste the handling is covered by the community and national waste legislation. In Sweden ashes are by and large being regarded as waste, and recycling is risk assessed and permits are given case by case. End-of-waste criteria for different waste material are being elaborated within the EU. Such criteria will among other details cover chemical safety. When a material fulfils the end-of-waste criteria such material

  6. FEM-based evaluation of deformable image registration for radiation therapy

    International Nuclear Information System (INIS)

    Zhong Hualiang; Peters, Terry; Siebers, Jeffrey V

    2007-01-01

    This paper presents a new concept to automatically detect the neighborhood in an image where deformable registration is mis-performing. Specifically, the displacement vector field (DVF) from a deformable image registration is substituted into a finite-element-based elastic framework to calculate unbalanced energy in each element. The value of the derived energy indicates the quality of the DVF in its neighborhood. The new voxel-based evaluation approach is compared with three other validation criteria: landmark measurement, a finite element approach and visual comparison, for deformable registrations performed with the optical-flow-based 'demons' algorithm as well as thin-plate spline interpolation. This analysis was performed on three pairs of prostate CT images. The results of the analysis show that the four criteria give mutually comparable quantitative assessments on the six registration instances. As an objective concept, the unbalanced energy presents no requirement on boundary constraints in its calculation, different from traditional mechanical modeling. This method is automatic, and at voxel level suitable to evaluate deformable registration in a clinical setting

  7. Comparison of time-series registration methods in breast dynamic infrared imaging

    Science.gov (United States)

    Riyahi-Alam, S.; Agostini, V.; Molinari, F.; Knaflitz, M.

    2015-03-01

    Automated motion reduction in dynamic infrared imaging is on demand in clinical applications, since movement disarranges time-temperature series of each pixel, thus originating thermal artifacts that might bias the clinical decision. All previously proposed registration methods are feature based algorithms requiring manual intervention. The aim of this work is to optimize the registration strategy specifically for Breast Dynamic Infrared Imaging and to make it user-independent. We implemented and evaluated 3 different 3D time-series registration methods: 1. Linear affine, 2. Non-linear Bspline, 3. Demons applied to 12 datasets of healthy breast thermal images. The results are evaluated through normalized mutual information with average values of 0.70 ±0.03, 0.74 ±0.03 and 0.81 ±0.09 (out of 1) for Affine, Bspline and Demons registration, respectively, as well as breast boundary overlap and Jacobian determinant of the deformation field. The statistical analysis of the results showed that symmetric diffeomorphic Demons' registration method outperforms also with the best breast alignment and non-negative Jacobian values which guarantee image similarity and anatomical consistency of the transformation, due to homologous forces enforcing the pixel geometric disparities to be shortened on all the frames. We propose Demons' registration as an effective technique for time-series dynamic infrared registration, to stabilize the local temperature oscillation.

  8. Validation of MRI to TRUS registration for high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Poulin, Eric; Boudam, Karim; Pinter, Csaba; Kadoury, Samuel; Lasso, Andras; Fichtinger, Gabor; Ménard, Cynthia

    The objective of this study was to develop and validate an open-source module for MRI to transrectal ultrasound (TRUS) registration to support tumor-targeted prostate brachytherapy. In this study, 15 patients with prostate cancer lesions visible on multiparametric MRI were selected for the validation. T2-weighted images with 1-mm isotropic voxel size and diffusion weighted images were acquired on a 1.5T Siemens imager. Three-dimensional (3D) TRUS images with 0.5-mm slice thickness were acquired. The investigated registration module was incorporated in the open-source 3D Slicer platform, which can compute rigid and deformable transformations. An extension of 3D Slicer, SlicerRT, allows import of and export to DICOM-RT formats. For validation, similarity indices, prostate volumes, and centroid positions were determined in addition to registration errors for common 3D points identified by an experienced radiation oncologist. The average time to compute the registration was 35 ± 3 s. For the rigid and deformable registration, respectively, Dice similarity coefficients were 0.87 ± 0.05 and 0.93 ± 0.01 while the 95% Hausdorff distances were 4.2 ± 1.0 and 2.2 ± 0.3 mm. MRI volumes obtained after the rigid and deformable registration were not statistically different (p > 0.05) from reference TRUS volumes. For the rigid and deformable registration, respectively, 3D distance errors between reference and registered centroid positions were 2.1 ± 1.0 and 0.4 ± 0.1 mm while registration errors between common points were 3.5 ± 3.2 and 2.3 ± 1.1 mm. Deformable registration was found significantly better (p < 0.05) than rigid registration for all parameters. An open-source MRI to TRUS registration platform was validated for integration in the brachytherapy workflow. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. Developing clinical strength-of-evidence approach to define HIV-associated malignancies for cancer registration in Kenya.

    Science.gov (United States)

    Korir, Anne; Mauti, Nathan; Moats, Pamela; Gurka, Matthew J; Mutuma, Geoffrey; Metheny, Christine; Mwamba, Peter M; Oyiro, Peter O; Fisher, Melanie; Ayers, Leona W; Rochford, Rosemary; Mwanda, Walter O; Remick, Scot C

    2014-01-01

    Sub-Saharan Africa cancer registries are beset by an increasing cancer burden further exacerbated by the AIDS epidemic where there are limited capabilities for cancer-AIDS match co-registration. We undertook a pilot study based on a "strength-of-evidence" approach using clinical data that is abstracted at the time of cancer registration for purposes of linking cancer diagnosis to AIDS diagnosis. The standard Nairobi Cancer Registry form was modified for registrars to abstract the following clinical data from medical records regarding HIV infection/AIDS in a hierarchal approach at time of cancer registration from highest-to-lowest strength-of-evidence: 1) documentation of positive HIV serology; 2) antiretroviral drug prescription; 3) CD4+ lymphocyte count; and 4) WHO HIV clinical stage or immune suppression syndrome (ISS), which is Kenyan terminology for AIDS. Between August 1 and October 31, 2011 a total of 1,200 cancer cases were registered. Of these, 171 cases (14.3%) met clinical strength-of-evidence criteria for association with HIV infection/AIDS; 69% (118 cases were tumor types with known HIV association - Kaposi's sarcoma, cervical cancer, non-Hodgkin's and Hodgkin's lymphoma, and conjunctiva carcinoma) and 31% (53) were consistent with non-AIDS defining cancers. Verifiable positive HIV serology was identified in 47 (27%) cases for an absolute seroprevalence rate of 4% among the cancer registered cases with an upper boundary of 14% among those meeting at least one of strength-of-evidence criteria. This pilot demonstration of a hierarchal, clinical strength-of-evidence approach for cancer-AIDS registration in Kenya establishes feasibility, is readily adaptable, pragmatic, and does not require additional resources for critically under staffed cancer registries. Cancer is an emerging public health challenge, and African nations need to develop well designed population-based studies in order to better define the impact and spectrum of malignant disease in the

  10. Individual Pesticides in Registration Review

    Science.gov (United States)

    You can used the Chemical Search database to search pesticides by chemical name and find their registration review dockets, along with Work Plans, risk assessments, interim and final decisions, tolerance rules, and cancellation actions.

  11. 27 CFR 53.140 - Registration.

    Science.gov (United States)

    2010-04-01

    ... of selling or purchasing articles tax free as provided in this section. In the case of a nonprofit....141. (e) Cross references. (1) For exceptions to the requirement for registration, see section 4222(b...

  12. A unifying probabilistic Bayesian approach to derive electron density from MRI for radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Gudur, Madhu Sudhan Reddy; Hara, Wendy; Le, Quynh-Thu; Wang, Lei; Xing, Lei; Li, Ruijiang

    2014-01-01

    MRI significantly improves the accuracy and reliability of target delineation in radiation therapy for certain tumors due to its superior soft tissue contrast compared to CT. A treatment planning process with MRI as the sole imaging modality will eliminate systematic CT/MRI co-registration errors, reduce cost and radiation exposure, and simplify clinical workflow. However, MRI lacks the key electron density information necessary for accurate dose calculation and generating reference images for patient setup. The purpose of this work is to develop a unifying method to derive electron density from standard T1-weighted MRI. We propose to combine both intensity and geometry information into a unifying probabilistic Bayesian framework for electron density mapping. For each voxel, we compute two conditional probability density functions (PDFs) of electron density given its: (1) T1-weighted MRI intensity, and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of the atlas and test patient. The two conditional PDFs containing intensity and geometry information are combined into a unifying posterior PDF, whose mean value corresponds to the optimal electron density value under the mean-square error criterion. We evaluated the algorithm’s accuracy of electron density mapping and its ability to detect bone in the head for eight patients, using an additional patient as the atlas or template. Mean absolute HU error between the estimated and true CT, as well as receiver operating characteristics for bone detection (HU > 200) were calculated. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 126, compared with 139 for deformable registration (p = 2  ×  10 −4 ), 283 for the intensity approach (p = 2  ×  10 −6 ) and 282

  13. Optic disc boundary segmentation from diffeomorphic demons registration of monocular fundus image sequences versus 3D visualization of stereo fundus image pairs for automated early stage glaucoma assessment

    Science.gov (United States)

    Gatti, Vijay; Hill, Jason; Mitra, Sunanda; Nutter, Brian

    2014-03-01

    Despite the current availability in resource-rich regions of advanced technologies in scanning and 3-D imaging in current ophthalmology practice, world-wide screening tests for early detection and progression of glaucoma still consist of a variety of simple tools, including fundus image-based parameters such as CDR (cup to disc diameter ratio) and CAR (cup to disc area ratio), especially in resource -poor regions. Reliable automated computation of the relevant parameters from fundus image sequences requires robust non-rigid registration and segmentation techniques. Recent research work demonstrated that proper non-rigid registration of multi-view monocular fundus image sequences could result in acceptable segmentation of cup boundaries for automated computation of CAR and CDR. This research work introduces a composite diffeomorphic demons registration algorithm for segmentation of cup boundaries from a sequence of monocular images and compares the resulting CAR and CDR values with those computed manually by experts and from 3-D visualization of stereo pairs. Our preliminary results show that the automated computation of CDR and CAR from composite diffeomorphic segmentation of monocular image sequences yield values comparable with those from the other two techniques and thus may provide global healthcare with a cost-effective yet accurate tool for management of glaucoma in its early stage.

  14. Analysis of the utilization of existing test data for phase-in substance registration under the Act on the Registration and Evaluation, etc. of Chemical Substances.

    Science.gov (United States)

    Choi, Bong-In; Kwak, Yeong-Don; Jung, Yu-Mi; Ryu, Byung-Taek; Kim, Chang Gyun

    2015-01-01

    Approximately 2000 phase-in substances are subject to registration according to the Act on the Registration and Evaluation, etc. of Chemical Substances (KREACH), and the expected testing cost is 2.06 trillion Korean won assuming all the test data required for registration are acquired. The extent to which these enormous test costs can be reduced depends on the availability of existing data that can be used to meet the requirements of the K-REACH we examined the current availability of test data that can be used for chemical substance registration. We analyzed the possibility of utilizing the existing test data obtained from 16 reference databases for 369 of 518 kinds of phase-in substances subject to registration that were reported in last October 2014. The physical and chemical properties were available for 57.1% of substances, whereas data regarding human hazards and environmental hazards were available at considerably lower rates, 8.5% and 11.8%, respectively. Physical and chemical properties were available for a fairly high proportion, whereas human hazards and environmental hazards were reported for considerably fewer substances.

  15. An efficient and robust algorithm for parallel groupwise registration of bone surfaces

    NARCIS (Netherlands)

    van de Giessen, Martijn; Vos, Frans M.; Grimbergen, Cornelis A.; van Vliet, Lucas J.; Streekstra, Geert J.

    2012-01-01

    In this paper a novel groupwise registration algorithm is proposed for the unbiased registration of a large number of densely sampled point clouds. The method fits an evolving mean shape to each of the example point clouds thereby minimizing the total deformation. The registration algorithm

  16. Complexity and accuracy of image registration methods in SPECT-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yin, L S; Duzenli, C; Moiseenko, V [Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1 (Canada); Tang, L; Hamarneh, G [Computing Science, Simon Fraser University, 9400 TASC1, Burnaby, BC, V5A 1S6 (Canada); Gill, B [Medical Physics, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Celler, A; Shcherbinin, S [Department of Radiology, University of British Columbia, 828 West 10th Ave, Vancouver, BC, V5Z 1L8 (Canada); Fua, T F; Thompson, A; Sheehan, F [Radiation Oncology, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Liu, M [Radiation Oncology, Fraser Valley Cancer Centre, BC Cancer Agency, 13750 9th Ave, Surrey, BC, V3V 1Z2 (Canada)], E-mail: lyin@bccancer.bc.ca

    2010-01-07

    The use of functional imaging in radiotherapy treatment (RT) planning requires accurate co-registration of functional imaging scans to CT scans. We evaluated six methods of image registration for use in SPECT-guided radiotherapy treatment planning. Methods varied in complexity from 3D affine transform based on control points to diffeomorphic demons and level set non-rigid registration. Ten lung cancer patients underwent perfusion SPECT-scans prior to their radiotherapy. CT images from a hybrid SPECT/CT scanner were registered to a planning CT, and then the same transformation was applied to the SPECT images. According to registration evaluation measures computed based on the intensity difference between the registered CT images or based on target registration error, non-rigid registrations provided a higher degree of accuracy than rigid methods. However, due to the irregularities in some of the obtained deformation fields, warping the SPECT using these fields may result in unacceptable changes to the SPECT intensity distribution that would preclude use in RT planning. Moreover, the differences between intensity histograms in the original and registered SPECT image sets were the largest for diffeomorphic demons and level set methods. In conclusion, the use of intensity-based validation measures alone is not sufficient for SPECT/CT registration for RTTP. It was also found that the proper evaluation of image registration requires the use of several accuracy metrics.

  17. 75 FR 51053 - Propetamphos; Notice of Receipt of Requests to Voluntarily Cancel Pesticide Registrations

    Science.gov (United States)

    2010-08-18

    ... of Requests to Voluntarily Cancel Pesticide Registrations AGENCY: Environmental Protection Agency... registrant, Wellmark International, to voluntarily cancel its registrations of products containing the... registrations have been canceled only if such sale, distribution, or use is consistent with the terms as...

  18. Registration of deformed multimodality medical images

    International Nuclear Information System (INIS)

    Moshfeghi, M.; Naidich, D.

    1989-01-01

    The registration and combination of images from different modalities have several potential applications, such as functional and anatomic studies, 3D radiation treatment planning, surgical planning, and retrospective studies. Image registration algorithms should correct for any local deformations caused by respiration, heart beat, imaging device distortions, and so forth. This paper reports on an elastic matching technique for registering deformed multimodality images. Correspondences between contours in the two images are used to stretch the deformed image toward its goal image. This process is repeated a number of times, with decreasing image stiffness. As the iterations continue, the stretched image better approximates its goal image

  19. An efficient similarity measure technique for medical image registration

    Indian Academy of Sciences (India)

    In this paper, an efficient similarity measure technique is proposed for medical image registration. The proposed approach is based on the Gerschgorin circles theorem. In this approach, image registration is carried out by considering Gerschgorin bounds of a covariance matrix of two compared images with normalized ...

  20. Improving Electronic Resources through Holistic Budgeting

    Science.gov (United States)

    Kusik, James P.; Vargas, Mark A.

    2009-01-01

    To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…

  1. Qualitative Improvement Methods Through Analysis of Inquiry Contents for Cancer Registration

    Science.gov (United States)

    Boo, Yoo-Kyung; Lim, Hyun-Sook; Kim, Jung-Eun; Kim, Kyoung-Beom; Won, Young-Joo

    2017-06-25

    Background: In Korea, the national cancer database was constructed after the initiation of the national cancer registration project in 1980, and the annual national cancer registration report has been published every year since 2005. Consequently, data management must begin even at the stage of data collection in order to ensure quality. Objectives: To determine the suitability of cancer registries’ inquiry tools through the inquiry analysis of the Korea Central Cancer Registry (KCCR), and identify the needs to improve the quality of cancer registration. Methods: Results of 721 inquiries to the KCCR from 2000 to 2014 were analyzed by inquiry year, question type, and medical institution characteristics. Using Stata version 14.1, descriptive analysis was performed to identify general participant characteristics, and chi-square analysis was applied to investigate significant differences in distribution characteristics by factors affecting the quality of cancer registration data. Results: The number of inquiries increased in 2005–2009. During this period, there were various changes, including the addition of cancer registration items such as brain tumors and guideline updates. Of the inquirers, 65.3% worked at hospitals in metropolitan cities and 60.89% of hospitals had 601–1000 beds. Tertiary hospitals had the highest number of inquiries (64.91%), and the highest number of questions by type were 353 (48.96%) for histological codes, 92 (12.76%) for primary sites, and 76 (10.54%) for reportable. Conclusions: A cancer registration inquiry system is an effective method when not confident about codes during cancer registration, or when confronting cancer cases in which previous clinical knowledge or information on the cancer registration guidelines are insufficient. Creative Commons Attribution License

  2. Study of different registration methods for on-line kilovoltage cone-beam CT guided lung cancer radiation

    International Nuclear Information System (INIS)

    Wang Yanyang; Fu Xiaolong; Xia Bing; Wu Zhengqin; Fan Min; Yang Huanjun; Xu Zhiyong; Jiang Guoliang

    2009-01-01

    Objective: To select the optimal registration method for on-line kilovoltage cone-beam CT (KVCBCT) guided lung cancer radiation and evaluate the reproducibility of the selected method. Methods: Sixteen patients with non-small cell lung cancer were enrolled into this study. A total of 96 pretreatment KVCBCT images from the 16 patients were available for the analysis. Image registration methods were bone-based automatic registration, gray-based automatic registration, manual registration and semi-automatic registration. All registrations were accomplished by one physician. Another physician blindly evaluated the results of each registration, then selected the optimal registration method and evaluated its reproducibility. Results: The average score of the bone-based automatic registration, gray-based automatic registration, manual registration and semi-automatic registration methods was 2.4, 2.7, 3.0 and 3.7, respectively. The score of the four different groups had statistics significant difference (F=42.20, P<0.001). Using the semi-automatic registration method, the probability of the difference between two registration results more than 3 mm in the left-right, superior-inferior, and anterior-posterior directions was 0, 3% and 6% by the same physician, 0, 14% and 0 by different physicians, and 8%, 14% and 8% by physician and radiation therapist. Conclusions: Semi-automatic registration method, possessing the highest score and accepted reproducibility, is appropriate for KVCBCT guided lung cancer radiation. (authors)

  3. Parallel Processing and Bio-inspired Computing for Biomedical Image Registration

    Directory of Open Access Journals (Sweden)

    Silviu Ioan Bejinariu

    2014-07-01

    Full Text Available Image Registration (IR is an optimization problem computing optimal parameters of a geometric transform used to overlay one or more source images to a given model by maximizing a similarity measure. In this paper the use of bio-inspired optimization algorithms in image registration is analyzed. Results obtained by means of three different algorithms are compared: Bacterial Foraging Optimization Algorithm (BFOA, Genetic Algorithm (GA and Clonal Selection Algorithm (CSA. Depending on the images type, the registration may be: area based, which is slow but more precise, and features based, which is faster. In this paper a feature based approach based on the Scale Invariant Feature Transform (SIFT is proposed. Finally, results obtained using sequential and parallel implementations on multi-core systems for area based and features based image registration are compared.

  4. Evaluation of body-wise and organ-wise registrations for abdominal organs

    Science.gov (United States)

    Xu, Zhoubing; Panjwani, Sahil A.; Lee, Christopher P.; Burke, Ryan P.; Baucom, Rebeccah B.; Poulose, Benjamin K.; Abramson, Richard G.; Landman, Bennett A.

    2016-03-01

    Identifying cross-sectional and longitudinal correspondence in the abdomen on computed tomography (CT) scans is necessary for quantitatively tracking change and understanding population characteristics, yet abdominal image registration is a challenging problem. The key difficulty in solving this problem is huge variations in organ dimensions and shapes across subjects. The current standard registration method uses the global or body-wise registration technique, which is based on the global topology for alignment. This method (although producing decent results) has substantial influence of outliers, thus leaving room for significant improvement. Here, we study a new image registration approach using local (organ-wise registration) by first creating organ-specific bounding boxes and then using these regions of interest (ROIs) for aligning references to target. Based on Dice Similarity Coefficient (DSC), Mean Surface Distance (MSD) and Hausdorff Distance (HD), the organ-wise approach is demonstrated to have significantly better results by minimizing the distorting effects of organ variations. This paper compares exclusively the two registration methods by providing novel quantitative and qualitative comparison data and is a subset of the more comprehensive problem of improving the multi-atlas segmentation by using organ normalization.

  5. 3D registration of surfaces for change detection in medical images

    Science.gov (United States)

    Fisher, Elizabeth; van der Stelt, Paul F.; Dunn, Stanley M.

    1997-04-01

    Spatial registration of data sets is essential for quantifying changes that take place over time in cases where the position of a patient with respect to the sensor has been altered. Changes within the region of interest can be problematic for automatic methods of registration. This research addresses the problem of automatic 3D registration of surfaces derived from serial, single-modality images for the purpose of quantifying changes over time. The registration algorithm utilizes motion-invariant, curvature- based geometric properties to derive an approximation to an initial rigid transformation to align two image sets. Following the initial registration, changed portions of the surface are detected and excluded before refining the transformation parameters. The performance of the algorithm was tested using simulation experiments. To quantitatively assess the registration, random noise at various levels, known rigid motion transformations, and analytically-defined volume changes were applied to the initial surface data acquired from models of teeth. These simulation experiments demonstrated that the calculated transformation parameters were accurate to within 1.2 percent of the total applied rotation and 2.9 percent of the total applied translation, even at the highest applied noise levels and simulated wear values.

  6. A coarse-to-fine scheme for groupwise registration of multisensor images

    Directory of Open Access Journals (Sweden)

    Yinghao Li

    2016-11-01

    Full Text Available Ensemble registration is concerned with a group of images that need to be registered simultaneously. It is challenging but important for many image analysis tasks such as vehicle detection and medical image fusion. To solve this problem effectively, a novel coarse-to-fine scheme for groupwise image registration is proposed. First, in the coarse registration step, unregistered images are divided into reference image set and float image set. The images of the two sets are registered based on segmented region matching. The coarse registration results are used as an initial solution for the next step. Then, in the fine registration step, a Gaussian mixture model with a local template is used to model the joint intensity of coarse-registered images. Meanwhile, a minimum message length criterion-based method is employed to determine the unknown number of mixing components. Based on this mixture model, a maximum likelihood framework is used to register a group of images. To evaluate the performance of the proposed approach, some representative groupwise registration approaches are compared on different image data sets. The experimental results show that the proposed approach has improved performance compared to conventional approaches.

  7. Continuous registration of optical absorption spectra of periodically produced solvated electrons

    International Nuclear Information System (INIS)

    Krebs, P.

    1975-01-01

    Absorption spectra of unstable intermediates, such as solvated electrons, were usually taken point by point, recording the time-dependent light absorption after their production by a flash. The experimental arrangement for continuous recording of the spectra consists of a conventional one beam spectral photometer with a stabilized white light source, a monochromator, and a light detector. By periodic production of light absorbing intermediates such as solvated electrons, e.g., by ac uv light, a small ac signal is modulated on the light detector output which after amplification can be continuously recorded as a function of wavelength. This method allows the detection of absorption spectra when disturbances from the outside provide a signal-to-noise ratio smaller than 1

  8. Improved image registration by sparse patch-based deformation estimation.

    Science.gov (United States)

    Kim, Minjeong; Wu, Guorong; Wang, Qian; Lee, Seong-Whan; Shen, Dinggang

    2015-01-15

    Despite intensive efforts for decades, deformable image registration is still a challenging problem due to the potential large anatomical differences across individual images, which limits the registration performance. Fortunately, this issue could be alleviated if a good initial deformation can be provided for the two images under registration, which are often termed as the moving subject and the fixed template, respectively. In this work, we present a novel patch-based initial deformation prediction framework for improving the performance of existing registration algorithms. Our main idea is to estimate the initial deformation between subject and template in a patch-wise fashion by using the sparse representation technique. We argue that two image patches should follow the same deformation toward the template image if their patch-wise appearance patterns are similar. To this end, our framework consists of two stages, i.e., the training stage and the application stage. In the training stage, we register all training images to the pre-selected template, such that the deformation of each training image with respect to the template is known. In the application stage, we apply the following four steps to efficiently calculate the initial deformation field for the new test subject: (1) We pick a small number of key points in the distinctive regions of the test subject; (2) for each key point, we extract a local patch and form a coupled appearance-deformation dictionary from training images where each dictionary atom consists of the image intensity patch as well as their respective local deformations; (3) a small set of training image patches in the coupled dictionary are selected to represent the image patch of each subject key point by sparse representation. Then, we can predict the initial deformation for each subject key point by propagating the pre-estimated deformations on the selected training patches with the same sparse representation coefficients; and (4) we

  9. Clinician‐selected Electronic Information Resources do not Guarantee Accuracy in Answering Primary Care Physicians’ Information Needs. A review of: McKibbon, K. Ann, and Douglas B. Fridsma. “Effectiveness of Clinician‐selected Electronic Information Resources for Answering Primary Care Physicians’ Information Needs.” Journal of the American Medical Informatics Association 13.6 (2006: 653‐9.

    Directory of Open Access Journals (Sweden)

    Martha Ingrid Preddie

    2008-03-01

    Full Text Available Objective – To determine if electronic information resources selected by primary care physicians improve their ability to answer simulated clinical questions.Design – An observational study utilizing hour‐long interviews and think‐aloud protocols.Setting – The offices and clinics of primary care physicians in Canada and the United States.Subjects – Twenty‐five primary care physicians of whom 4 were women, 17 were from Canada, 22 were family physicians,and 24 were board certified.Methods – Participants provided responses to 23 multiple‐choice questions. Each physician then chose two questions and looked for the answers utilizing information resources of their own choice. The search processes, chosen resources and search times were noted. These were analyzed along with data on the accuracy of the answers and certainties related to the answer to each clinical question prior to the search.Main results – Twenty‐three physicians sought answers to 46 simulated clinical questions. Utilizing only electronic information resources, physicians spent a mean of 13.0 (SD 5.5 minutes searching for answers to the questions, an average of 7.3(SD 4.0 minutes for the first question and 5.8 (SD 2.2 minutes to answer the second question. On average, 1.8 resources were utilized per question. Resources that summarized information, such as the Cochrane Database of Systematic Reviews, UpToDate and Clinical Evidence, were favored 39.2% of the time, MEDLINE (Ovid and PubMed 35.7%, and Internet resources including Google 22.6%. Almost 50% of the search and retrieval strategies were keyword‐based, while MeSH, subheadings and limiting were used less frequently. On average, before searching physicians answered 10 of 23 (43.5% questions accurately. For questions that were searched using clinician‐selected electronic resources, 18 (39.1% of the 46 answers were accurate before searching, while 19 (42.1% were accurate after searching. The difference of

  10. Patient-Specific Biomechanical Model as Whole-Body CT Image Registration Tool

    OpenAIRE

    Li, Mao; Miller, Karol; Joldes, Grand Roman; Doyle, Barry; Garlapati, Revanth Reddy; Kikinis, Ron; Wittek, Adam

    2015-01-01

    Whole-body computed tomography (CT) image registration is important for cancer diagnosis, therapy planning and treatment. Such registration requires accounting for large differences between source and target images caused by deformations of soft organs/tissues and articulated motion of skeletal structures. The registration algorithms relying solely on image processing methods exhibit deficiencies in accounting for such deformations and motion. We propose to predict the deformations and moveme...

  11. 21 CFR 1.240 - What other registration requirements apply?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false What other registration requirements apply? 1.240 Section 1.240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GENERAL ENFORCEMENT REGULATIONS Registration of Food Facilities Additional Provisions § 1.240 What other...

  12. 75 FR 30824 - Methidathion; Cancellation Order for Pesticide Registrations

    Science.gov (United States)

    2010-06-02

    ... distribution, sale, or use of existing stocks of the products identified in Unit II., Table 1, in a manner..., 2010, Federal Register notice of receipt of requests from the registrants listed in Unit II., Table 2... Table 1 of this unit. Table 1.--Methidathion Product Cancellations Registration Number Product Name...

  13. Supervised Quality Assessment Of Medical Image Registration: Application to intra-patient CT lung registration

    NARCIS (Netherlands)

    Muenzing, S.E.; Ginneken, B. van; Murphy, K.; Pluim, J.P.

    2012-01-01

    A novel method for automatic quality assessment of medical image registration is presented. The method is based on supervised learning of local alignment patterns, which are captured by statistical image features at distinctive landmark points. A two-stage classifier cascade, employing an optimal

  14. Supervised quality assessment of medical image registration : application to intra-patient CT lung registration

    NARCIS (Netherlands)

    Muenzing, S.E.A.; Ginneken, van B.; Murphy, K.; Pluim, J.P.W.

    2012-01-01

    A novel method for automatic quality assessment of medical image registration is presented. The method is based on supervised learning of local alignment patterns, which are captured by statistical image features at distinctive landmark points. A two-stage classifier cascade, employing an optimal

  15. Critical issues related to registration of space objects and transparency of space activities

    Science.gov (United States)

    Jakhu, Ram S.; Jasani, Bhupendra; McDowell, Jonathan C.

    2018-02-01

    The main purpose of the 1975 Registration Convention is to achieve transparency in space activities and this objective is motivated by the belief that a mandatory registration system would assist in the identification of space objects launched into outer space. This would also consequently contribute to the application and development of international law governing the exploration and use of outer space. States Parties to the Convention furnish the required information to the United Nations' Register of Space Objects. However, the furnished information is often so general that it may not be as helpful in creating transparency as had been hoped by the drafters of the Convention. While registration of civil satellites has been furnished with some general details, till today, none of the Parties have described the objects as having military functions despite the fact that a large number of such objects do perform military functions as well. In some cases, the best they have done is to indicate that the space objects are for their defense establishments. Moreover, the number of registrations of space objects is declining. This paper addresses the challenges posed by the non-registration of space objects. Particularly, the paper provides some data about the registration and non-registration of satellites and the States that have and have not complied with their legal obligations. It also analyses the specific requirements of the Convention, the reasons for non-registration, new challenges posed by the registration of small satellites and the on-orbit transfer of satellites. Finally, the paper provides some recommendations on how to enhance the registration of space objects, on the monitoring of the implementation of the Registration Convention and consequently how to achieve maximum transparency in space activities.

  16. Error estimation of deformable image registration of pulmonary CT scans using convolutional neural networks

    NARCIS (Netherlands)

    Eppenhof, K.A.J.; Pluim, J.P.W.

    2018-01-01

    Error estimation in nonlinear medical image registration is a nontrivial problem that is important for validation of registration methods. We propose a supervised method for estimation of registration errors in nonlinear registration of three-dimensional (3-D) images. The method is based on a 3-D

  17. 17 CFR 230.487 - Effectiveness of registration statements filed by certain unit investment trusts.

    Science.gov (United States)

    2010-04-01

    ... Investment Companies; Business Development Companies § 230.487 Effectiveness of registration statements filed... Company Act of 1940 that files a registration statement pursuant to the Act in connection with the..., may designate a date and time for such registration statement to become effective. If the registrant...

  18. Review of material recovery from used electric and electronic equipment-alternative options for resource conservation.

    Science.gov (United States)

    Friege, Henning

    2012-09-01

    For waste from electric and electronic equipment, the WEEE Directive stipulates the separate collection of electric and electronic waste. As to new electric and electronic devices, the Restriction of Hazardous Substances (RoHS) Directive bans the use of certain chemicals dangerous for man and environment. From the implementation of the WEEE directive, many unsolved problems have been documented: poor collection success, emission of dangerous substances during collection and recycling, irretrievable loss of valuable metals among others. As to RoHS, data from the literature show a satisfying success. The problems identified in the process can be reduced to some basic dilemmas at the borders between waste management, product policy and chemical safety. The objectives of the WEEE Directive and the specific targets for use and recycling of appliances are not consistent. There is no focus on scarce resources. Extended producer responsibility is not sufficient to guarantee sustainable waste management. Waste management reaches its limits due to problems of implementation but also due to physical laws. A holistic approach is necessary looking at all branch points and sinks in the stream of used products and waste from electric and electronic equipment. This may be done with respect to the general rules for sustainable management of material streams covering the three dimensions of sustainable policy. The relationships between the players in the field of electric and electronic devices have to be taken into account. Most of the problems identified in the implementation process will not be solved by the current amendment of the WEEE Directive.

  19. Registration of vehicles at the Gex sous-préfecture: now by appointment only

    CERN Multimedia

    2016-01-01

    The Gex sous-préfecture has informed CERN that it has taken the following steps in order to reduce waiting times at its counters for the issue of carte grise vehicle registration certificates. As of 1 February 2016, you must book an appointment via the website http://www.rdv.ain.gouv.fr/ for all services relating to the registration of vehicles, in particular the:   change of the holder of a registration certificate, issue of a certificat de situation administrative (administrative status certificate required for the sale of a vehicle), change of marital status (or company name in the case of legal entities), change of address, change in the technical specification of the vehicle, corrections to registration certificates, equests for duplicates (loss or theft of registration certificates), registration of a diplomatic vehicle (CERN), registration of a new vehicle, registration of vehicles purchased tax-free in the Pays de Gex free zone (formerly TTW series), and import of vehicles (from ...

  20. Charting a Course through CORAL: Texas A&M University Libraries' Experience Implementing an Open-Source Electronic Resources Management System

    Science.gov (United States)

    Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona

    2013-01-01

    In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…

  1. 26 CFR 41.6001-2 - Proof of payment for State registration purposes.

    Science.gov (United States)

    2010-04-01

    ... of payment if such vehicles are registered under a “suspension” registration system. Registration of a vehicle subject to tax under a suspension system must be on the condition that, (i) the State... suspension of registration, the State must not allow the vehicle to be registered until valid proof of...

  2. Automated robust registration of grossly misregistered whole-slide images with varying stains

    Science.gov (United States)

    Litjens, G.; Safferling, K.; Grabe, N.

    2016-03-01

    Cancer diagnosis and pharmaceutical research increasingly depend on the accurate quantification of cancer biomarkers. Identification of biomarkers is usually performed through immunohistochemical staining of cancer sections on glass slides. However, combination of multiple biomarkers from a wide variety of immunohistochemically stained slides is a tedious process in traditional histopathology due to the switching of glass slides and re-identification of regions of interest by pathologists. Digital pathology now allows us to apply image registration algorithms to digitized whole-slides to align the differing immunohistochemical stains automatically. However, registration algorithms need to be robust to changes in color due to differing stains and severe changes in tissue content between slides. In this work we developed a robust registration methodology to allow for fast coarse alignment of multiple immunohistochemical stains to the base hematyoxylin and eosin stained image. We applied HSD color model conversion to obtain a less stain color dependent representation of the whole-slide images. Subsequently, optical density thresholding and connected component analysis were used to identify the relevant regions for registration. Template matching using normalized mutual information was applied to provide initial translation and rotation parameters, after which a cost function-driven affine registration was performed. The algorithm was validated using 40 slides from 10 prostate cancer patients, with landmark registration error as a metric. Median landmark registration error was around 180 microns, which indicates performance is adequate for practical application. None of the registrations failed, indicating the robustness of the algorithm.

  3. Feature-based US to CT registration of the aortic root

    Science.gov (United States)

    Lang, Pencilla; Chen, Elvis C. S.; Guiraudon, Gerard M.; Jones, Doug L.; Bainbridge, Daniel; Chu, Michael W.; Drangova, Maria; Hata, Noby; Jain, Ameet; Peters, Terry M.

    2011-03-01

    A feature-based registration was developed to align biplane and tracked ultrasound images of the aortic root with a preoperative CT volume. In transcatheter aortic valve replacement, a prosthetic valve is inserted into the aortic annulus via a catheter. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to significant morbidity and mortality. Registration of pre-operative CT to transesophageal ultrasound and fluoroscopy images is a major step towards providing augmented image guidance for this procedure. The proposed registration approach uses an iterative closest point algorithm to register a surface mesh generated from CT to 3D US points reconstructed from a single biplane US acquisition, or multiple tracked US images. The use of a single simultaneous acquisition biplane image eliminates reconstruction error introduced by cardiac gating and TEE probe tracking, creating potential for real-time intra-operative registration. A simple initialization procedure is used to minimize changes to operating room workflow. The algorithm is tested on images acquired from excised porcine hearts. Results demonstrate a clinically acceptable accuracy of 2.6mm and 5mm for tracked US to CT and biplane US to CT registration respectively.

  4. Evaluating a method for automated rigid registration

    DEFF Research Database (Denmark)

    Darkner, Sune; Vester-Christensen, Martin; Larsen, Rasmus

    2007-01-01

    to point distance. T-test for common mean are used to determine the performance of the two methods (supported by a Wilcoxon signed rank test). The performance influence of sampling density, sampling quantity, and norms is analyzed using a similar method.......We evaluate a novel method for fully automated rigid registration of 2D manifolds in 3D space based on distance maps, the Gibbs sampler and Iterated Conditional Modes (ICM). The method is tested against the ICP considered as the gold standard for automated rigid registration. Furthermore...

  5. A national multicenter registration study. Omalizumb in children in Denmark

    DEFF Research Database (Denmark)

    Spangberg, Katrien; Jørgensen, Inger Merete; Agertoft, Lone

    Background: In Denmark, Omalizumab is approved to treat children with severe persistent allergic asthma older than 6 years of age. No systematic registration of the efficacy in the Danish child population according to asthma symptoms or of the efficacy on co-morbid allergic symptoms exists. Results...... from a pilot study show that a broad panel of outcome measures is necessary to evaluate the efficacy of Omalizumab treatment as no change in lung function could be demonstrated Aim: To provide a standardized systematic registration in order to create a database enrolling children with severe allergic...... asthma treated with Omalizumab. Method and study design: A national multicenter registration and follow-up study based on children with clinical persistent severe allergic asthma including both retrospective and prospective registration. Inclusion criteria: • 6-18 years of age. • Severe persistent...

  6. Computed tomography lung iodine contrast mapping by image registration and subtraction

    Science.gov (United States)

    Goatman, Keith; Plakas, Costas; Schuijf, Joanne; Beveridge, Erin; Prokop, Mathias

    2014-03-01

    Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aquilion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57mm (range 1.43-4.34 mm), and following registration the mean error was 0.54mm (range 0.44-0.64 mm). The mean surface error distance was 1.89mm before registration and 0.47mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction

  7. Image registration in the brain: a test of clinical accuracy

    International Nuclear Information System (INIS)

    Rosenman, Julian; Miller, Elizabeth P.; Rinker, Lillian; Mukherji, Suresh; Tracton, Gregg; Cullip, Tim J.; Muller, Keith E.; DeLuca, Marla C.; Major, Stacey A.; Sailer, Scott; Varia, Mahesh

    1997-01-01

    Purpose/Objective: Accurate localization of tumor and normal structures is a critical step in the radiation treatment planning processes and has direct implications for tumor control success as well as normal tissue morbidity. We conducted a study to determine the accuracy of transferring tumor information from diagnostic images to the simulation films and planning CT with conventional methods using the best clinical judgment and compared that to tumor localization using 3D registration software. Materials and Methods: We measured the accuracy with which experienced clinicians could localize tumor volume from diagnostic images to either simulation films or a planning CT, with and without 3D registration software. To obtain absolute registration truth we used the method of identical pairs wherein a CT data set was duplicated and one copy resliced along a different plane than the original while maintaining the exact mathematical transformation between them. A tumor was then added to the resliced CT which became the surrogate diagnostic image. Because we were concerned that a CT/CT pair might be too easy to register, a simulated MR made by re-colorizing the resliced CT (to become a facsimile MR or fMR) was also used as a surrogate diagnostic image. Finally we studied the registration accuracy when a CT/(real)MR pair was used. The registration in this case could not be guaranteed to be exact, but the studies were obtained under carefully controlled conditions and were registered from bony landmarks using commercial radiosurgery software. A team of experts then placed the tumor from the resliced CT, fMR, or real MR to an AP and lateral 'isocenter simulation film' (a digitally reconstructed radiograph made from the unmarked CT) and to the 'planning CT' - also the unmarked CT. A registration of the data sets (CT/CT, CT/fMR and CT/MR) was also done using our 3D registration software. A total of thirty-six tasks on four subjects were performed. Four analyses (each with

  8. Multibeam 3D Underwater SLAM with Probabilistic Registration

    Directory of Open Access Journals (Sweden)

    Albert Palomer

    2016-04-01

    Full Text Available This paper describes a pose-based underwater 3D Simultaneous Localization and Mapping (SLAM using a multibeam echosounder to produce high consistency underwater maps. The proposed algorithm compounds swath profiles of the seafloor with dead reckoning localization to build surface patches (i.e., point clouds. An Iterative Closest Point (ICP with a probabilistic implementation is then used to register the point clouds, taking into account their uncertainties. The registration process is divided in two steps: (1 point-to-point association for coarse registration and (2 point-to-plane association for fine registration. The point clouds of the surfaces to be registered are sub-sampled in order to decrease both the computation time and also the potential of falling into local minima during the registration. In addition, a heuristic is used to decrease the complexity of the association step of the ICP from O ( n 2 to O ( n . The performance of the SLAM framework is tested using two real world datasets: First, a 2.5D bathymetric dataset obtained with the usual down-looking multibeam sonar configuration, and second, a full 3D underwater dataset acquired with a multibeam sonar mounted on a pan and tilt unit.

  9. Fast time-of-flight camera based surface registration for radiotherapy patient positioning.

    Science.gov (United States)

    Placht, Simon; Stancanello, Joseph; Schaller, Christian; Balda, Michael; Angelopoulou, Elli

    2012-01-01

    This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an "ICP only" strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 ± 1.08 mm and 0.07° ± 0.05°, respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration technologies. Its main benefit is the

  10. Fast time-of-flight camera based surface registration for radiotherapy patient positioning

    International Nuclear Information System (INIS)

    Placht, Simon; Stancanello, Joseph; Schaller, Christian; Balda, Michael; Angelopoulou, Elli

    2012-01-01

    Purpose: This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. Methods: A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an ''ICP only'' strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. Results: The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 ± 1.08 mm and 0.07 deg. ± 0.05 deg., respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. Conclusions: The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration

  11. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false How and when do you cancel your facility's... for Registration of Food Facilities § 1.235 How and when do you cancel your facility's registration information? (a) Notification of registration cancellation. A facility canceling its registration must do so...

  12. 75 FR 43166 - Information Collection; Central Contractor Registration Requirements for Prime Grant Recipients

    Science.gov (United States)

    2010-07-23

    ...] Information Collection; Central Contractor Registration Requirements for Prime Grant Recipients AGENCY: Office... information collection requirement regarding Central Contractor Registration Requirements for Prime Grant... for the proper performance of functions of the Central Contractor Registration Requirements for Prime...

  13. Non-rigid registration of tomographic images with Fourier transforms

    International Nuclear Information System (INIS)

    Osorio, Ar; Isoardi, Ra; Mato, G

    2007-01-01

    Spatial image registration of deformable body parts such as thorax and abdomen has important medical applications, but at the same time, it represents an important computational challenge. In this work we propose an automatic algorithm to perform non-rigid registration of tomographic images using a non-rigid model based on Fourier transforms. As a measure of similarity, we use the correlation coefficient, finding that the optimal order of the transformation is n = 3 (36 parameters). We apply this method to a digital phantom and to 7 pairs of patient images corresponding to clinical CT scans. The preliminary results indicate a fairly good agreement according to medical experts, with an average registration error of 2 mm for the case of clinical images. For 2D images (dimensions 512x512), the average running time for the algorithm is 15 seconds using a standard personal computer. Summarizing, we find that intra-modality registration of the abdomen can be achieved with acceptable accuracy for slight deformations and can be extended to 3D with a reasonable execution time

  14. Automatic selective feature retention in patient specific elastic surface registration

    CSIR Research Space (South Africa)

    Jansen van Rensburg, GJ

    2011-01-01

    Full Text Available The accuracy with which a recent elastic surface registration algorithm deforms the complex geometry of a skull is examined. This algorithm is then coupled to a line based algorithm as is frequently used in patient specific feature registration...

  15. Comparing registration methods for mapping brain change using tensor-based morphometry.

    Science.gov (United States)

    Yanovsky, Igor; Leow, Alex D; Lee, Suh; Osher, Stanley J; Thompson, Paul M

    2009-10-01

    Measures of brain changes can be computed from sequential MRI scans, providing valuable information on disease progression for neuroscientific studies and clinical trials. Tensor-based morphometry (TBM) creates maps of these brain changes, visualizing the 3D profile and rates of tissue growth or atrophy. In this paper, we examine the power of different nonrigid registration models to detect changes in TBM, and their stability when no real changes are present. Specifically, we investigate an asymmetric version of a recently proposed Unbiased registration method, using mutual information as the matching criterion. We compare matching functionals (sum of squared differences and mutual information), as well as large-deformation registration schemes (viscous fluid and inverse-consistent linear elastic registration methods versus Symmetric and Asymmetric Unbiased registration) for detecting changes in serial MRI scans of 10 elderly normal subjects and 10 patients with Alzheimer's Disease scanned at 2-week and 1-year intervals. We also analyzed registration results when matching images corrupted with artificial noise. We demonstrated that the unbiased methods, both symmetric and asymmetric, have higher reproducibility. The unbiased methods were also less likely to detect changes in the absence of any real physiological change. Moreover, they measured biological deformations more accurately by penalizing bias in the corresponding statistical maps.

  16. Increasing the automation of a 2D-3D registration system.

    Science.gov (United States)

    Varnavas, Andreas; Carrell, Tom; Penney, Graeme

    2013-02-01

    Routine clinical use of 2D-3D registration algorithms for Image Guided Surgery remains limited. A key aspect for routine clinical use of this technology is its degree of automation, i.e., the amount of necessary knowledgeable interaction between the clinicians and the registration system. Current image-based registration approaches usually require knowledgeable manual interaction during two stages: for initial pose estimation and for verification of produced results. We propose four novel techniques, particularly suited to vertebra-based registration systems, which can significantly automate both of the above stages. Two of these techniques are based upon the intraoperative "insertion" of a virtual fiducial marker into the preoperative data. The remaining two techniques use the final registration similarity value between multiple CT vertebrae and a single fluoroscopy vertebra. The proposed methods were evaluated with data from 31 operations (31 CT scans, 419 fluoroscopy images). Results show these methods can remove the need for manual vertebra identification during initial pose estimation, and were also very effective for result verification, producing a combined true positive rate of 100% and false positive rate equal to zero. This large decrease in required knowledgeable interaction is an important contribution aiming to enable more widespread use of 2D-3D registration technology.

  17. Appraising the quality of sub-Saharan African cancer registration systems that contributed to GLOBOCAN 2008: a review of the literature and critical appraisal.

    Science.gov (United States)

    Crocker-Buque, Tim; Pollock, Allyson M

    2015-02-01

    To critically appraise the quality of sub-Saharan African cancer registration systems that submitted data to GLOBOCAN 2008 with respect to population coverage using publicly available information and to show the use of GLOBOCAN statistics in determining global health priorities. Sources of cancer registration data for twenty-six sub-Saharan African cancer registries were identified from GLOBOCAN 2008 factsheets. Additional information was extracted from International Agency for Research on Cancer publications. A literature search was conducted to identify studies that reported additional information on data collection methods and provided 27 studies. The websites of the 10 largest funders of development assistance for health were searched for GLOBOCAN citations. Twenty-six sub-Saharan African cancer registration systems submitting data to GLOBOCAN 2008 in relation to 21 countries. Information on 15 quality variables were extracted and compared with the international gold standard for cancer registration systems. Population coverage of the cancer registries ranged from from 2.3% of the population in Kenya to 100% in The Gambia, with a heavy urban bias in all countries. However, 20 countries (300 million people) had no cancer registration systems. Nineteen of the 26 registries failed to meet more than five of the 15 quality criteria and only one country met more than 10. Seven of the 10 largest funders of development assistance for health cite GLOBOCAN statistics in support of policy priorities. GLOBOCAN 2008 estimates are based on data drawn from poor quality cancer registration systems, with limited or no population registry coverage. It is essential the GLOBOCAN 2012 estimates should provide information on the quality of the data collection and explain the limitations of the estimates. Development organisations and the World Health Organization need to take a more cautious approach when using these data to determine priorities and allocating resources. © The

  18. Image/patient registration from (partial) projection data by the Fourier phase matching method

    International Nuclear Information System (INIS)

    Weiguo Lu; You, J.

    1999-01-01

    A technique for 2D or 3D image/patient registration, PFPM (projection based Fourier phase matching method), is proposed. This technique provides image/patient registration directly from sequential tomographic projection data. The method can also deal with image files by generating 2D Radon transforms slice by slice. The registration in projection space is done by calculating a Fourier invariant (FI) descriptor for each one-dimensional projection datum, and then registering the FI descriptor by the Fourier phase matching (FPM) method. The algorithm has been tested on both synthetic and experimental data. When dealing with translated, rotated and uniformly scaled 2D image registration, the performance of the PFPM method is comparable to that of the IFPM (image based Fourier phase matching) method in robustness, efficiency, insensitivity to the offset between images, and registration time. The advantages of the former are that subpixel resolution is feasible, and it is more insensitive to image noise due to the averaging effect of the projection acquisition. Furthermore, the PFPM method offers the ability to generalize to 3D image/patient registration and to register partial projection data. By applying patient registration directly from tomographic projection data, image reconstruction is not needed in the therapy set-up verification, thus reducing computational time and artefacts. In addition, real time registration is feasible. Registration from partial projection data meets the geometry and dose requirements in many application cases and makes dynamic set-up verification possible in tomotherapy. (author)

  19. 78 FR 14540 - Chlorpyrifos Registration Review; Preliminary Volatilization Assessment; Extension of Comment Period

    Science.gov (United States)

    2013-03-06

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OPP-2008-0850; FRL-9380-7] Chlorpyrifos Registration... Federal Register issue of February 6, 2013, concerning Chlorpyrifos Registration Review; Preliminary... volatilization assessment for the registration review of chlorpyrifos. EPA received requests from several...

  20. Designing a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology

    Directory of Open Access Journals (Sweden)

    Mirali Seyednaghavi

    2017-06-01

    Full Text Available : In the first phase of this study a model for electronic human resource management in government agencies based on new public services was explored by using software MAXQDA, then in the second phase, relationship between the elements of the theory were tested using software Smart PLS2. So the aim of this study is to design a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology. In this regard, according to Strauss and Corbin’s structured plan, five hypotheses were tested. Quantitative data analysis indicates that the pressures of the policies and global perspectives cause to move toward e-HRM. Among the contextual conditions macro structural mechanisms, considerations of actors, governance considerations have a significant impact on the strategy of new public services and therefore lead to the consequences of its implementation in public organizations. The findings suggest that e-HRM does not have a positive and meaningful impact on new public services, and in our country, although the recent political developments have somehow removed the gap between public policy makers, administrators, and the public, but there is still a long way to go.

  1. Emotional intelligence education in pre-registration nursing programmes: an integrative review.

    Science.gov (United States)

    Foster, Kim; McCloughen, Andrea; Delgado, Cynthia; Kefalas, Claudia; Harkness, Emily

    2015-03-01

    To investigate the state of knowledge on emotional intelligence (EI) education in pre-registration nursing programmes. Integrative literature review. CINAHL, Medline, Scopus, ERIC, and Web of Knowledge electronic databases were searched for abstracts published in English between 1992-2014. Data extraction and constant comparative analysis of 17 articles. Three categories were identified: Constructs of emotional intelligence; emotional intelligence curricula components; and strategies for emotional intelligence education. A wide range of emotional intelligence constructs were found, with a predominance of trait-based constructs. A variety of strategies to enhance students' emotional intelligence skills were identified, but limited curricula components and frameworks reported in the literature. An ability-based model for curricula and learning and teaching approaches is recommended. Copyright © 2014. Published by Elsevier Ltd.

  2. A first step toward uncovering the truth about weight tuning in deformable image registration

    Science.gov (United States)

    Pirpinia, Kleopatra; Bosman, Peter A. N.; Sonke, Jan-Jakob; van Herk, Marcel; Alderliesten, Tanja

    2016-03-01

    Deformable image registration is currently predominantly solved by optimizing a weighted linear combination of objectives. Successfully tuning the weights associated with these objectives is not trivial, leading to trial-and-error approaches. Such an approach assumes an intuitive interplay between weights, optimization objectives, and target registration errors. However, it is not known whether this always holds for existing registration methods. To investigate the interplay between weights, optimization objectives, and registration errors, we employ multi-objective optimization. Here, objectives of interest are optimized simultaneously, causing a set of multiple optimal solutions to exist, called the optimal Pareto front. Our medical application is in breast cancer and includes the challenging prone-supine registration problem. In total, we studied the interplay in three different ways. First, we ran many random linear combinations of objectives using the well-known registration software elastix. Second, since the optimization algorithms used in registration are typically of a local-search nature, final solutions may not always form a Pareto front. We therefore employed a multi-objective evolutionary algorithm that finds weights that correspond to registration outcomes that do form a Pareto front. Third, we examined how the interplay differs if a true multi-objective (i.e., weight-free) image registration method is used. Results indicate that a trial-and-error weight-adaptation approach can be successful for the easy prone to prone breast image registration case, due to the absence of many local optima. With increasing problem difficulty the use of more advanced approaches can be of value in finding and selecting the optimal registration outcomes.

  3. Frameless image registration of X-ray CT and SPECT by volume matching

    International Nuclear Information System (INIS)

    Tanaka, Yuko; Kihara, Tomohiko; Yui, Nobuharu; Kinoshita, Fujimi; Kamimura, Yoshitsugu; Yamada, Yoshifumi.

    1998-01-01

    Image registration of functional (SPECT) and morphological (X-ray CT/MRI) images is studied in order to improve the accuracy and the quantity of the image diagnosis. We have developed a new frameless registration method of X-ray CT and SPECT image using transmission CT image acquired for absorption correction of SPECT images. This is the automated registration method and calculates the transformation matrix between the two coordinate systems of image data by the optimization method. This registration method is based on the similar physical property of X-ray CT and transmission CT image. The three-dimensional overlap of the bone region is used for image matching. We verified by a phantom test that it can provide a good result of within two millimeters error. We also evaluated visually the accuracy of the registration method by the application study of SPECT, X-ray CT, and transmission CT head images. This method can be carried out accurately without any frames. We expect this registration method becomes an efficient tool to improve image diagnosis and medical treatment. (author)

  4. Registration of Plant Varieties

    African Journals Online (AJOL)

    Registration of two Sorghum Hybrids, ESH-1 and ESH-2. Sorghum (Sorghum bicolor (L) Moench) is an indigenous crop to Ethiopia and staple for many millions of people in most parts of Africa. The crop is one of the most important cereals grown in arid and semi arid areas where others often fail to survive. In Eastern Africa ...

  5. A PRIVACY-PRESERVING ENCRYPTION SCHEME FOR AN INTERNET REALNAME REGISTRATION SYSTEM

    OpenAIRE

    Xu , Fei; Yau , Ken; Zhang , Ping; Chow , Kam-Pui

    2015-01-01

    Part 2: INTERNET CRIME INVESTIGATIONS; International audience; Internet real-name registration requires a user to provide personal identification credentials including his/her real name to an online service provider when registering for an account. In China, real-name registration has been implemented since 2010 for purchasing train tickets and mobile phone SIM cards. In 2013, the Chinese government announced that real-name registration would be implemented for Internet users to protect again...

  6. Roentgenologic characteristic of 7 group contingent of dispensary registration

    International Nuclear Information System (INIS)

    Derzhavin, V.I.; Nalivajko, N.N.; Kozlova, L.N.; Petrik, R.N.

    1984-01-01

    9694 persons of 7 group contingent of dispensary registration were examined. Roentgenologic study of posttuberculous changes of 7 group contingent of dispensary registration showed that in people of 7-A subgroup prevail processes of secondary genesis (79.4%) and in people of 7-B subgroup - of primary genesis (55.8%). Consequences of secondary tuberculosis are most recurring

  7. Signal shape registration in the JINR synchrophasotron slowly extracted beam parameter control system

    International Nuclear Information System (INIS)

    Volkov, V.I.; Kulikov, I.I.; Romanov, S.V.

    1982-01-01

    Signal shape registration in the JINR synchrophasotron slowly estracted beam parameter control system on-line with the ES-1010 computer is described. 32 input signals can be connected to the registrator. The maximum measurement rate of signal shape registration is about 38 kHz. The registrator consists of 32-channel analog multiplexer, 10-bit analog-to-digital converter, 1024-word buffer memory and control circuits. For information representation the colour TV monitor is used

  8. 78 FR 18586 - Registration Review; Pesticide Dockets Opened for Review and Comment and Other Docket Acts

    Science.gov (United States)

    2013-03-27

    ...With this document, EPA is opening the public comment period for several registration reviews. Registration review is EPA's periodic review of pesticide registrations to ensure that each pesticide continues to satisfy the statutory standard for registration, that is, the pesticide can perform its intended function without unreasonable adverse effects on human health or the environment. Registration review dockets contain information that will assist the public in understanding the types of information and issues that the Agency may consider during the course of registration reviews. Through this program, EPA is ensuring that each pesticide's registration is based on current scientific and other knowledge, including its effects on human health and the environment. This document also announces the Agency's intent not to open registration review dockets for iodomethane or ethametsulfuron-methyl. Iodomethane and ethametsulfuron-methyl are undergoing phase-outs of all U.S. pesticide registrations. The cancellations of the iodomethane end use registrations became effective on December 31, 2012, and the cancellation of the sole technical product registration will become effective on December 1, 2015. The cancellations of all ethametsulfuron-methyl product registrations became effective on February 20, 2013. Therefore, iodomethane and ethametsulfuron-methyl are not scheduled for review under the registration review program. This document also announces the registration review case closures for the pesticides alkyl amine hydrochloride (case 3051) and halofenozide (case 7425), and the availability of their respective Case Closure Documents. The cancellation of all alkyl amine hydrochloride registrations became effective on October 17, 2012. The cancellation of all U.S. halofenozide registrations became effective December 21, 2012. These case closure are being announced herein with no comment period.

  9. PARALLEL AND ADAPTIVE UNIFORM-DISTRIBUTED REGISTRATION METHOD FOR CHANG’E-1 LUNAR REMOTE SENSED IMAGERY

    Directory of Open Access Journals (Sweden)

    X. Ning

    2012-08-01

    To resolve the above-mentioned registration difficulties, a parallel and adaptive uniform-distributed registration method for CE-1 lunar remote sensed imagery is proposed in this paper. Based on 6 pairs of randomly selected images, both the standard SIFT algorithm and the parallel and adaptive uniform-distributed registration method were executed, the versatility and effectiveness were assessed. The experimental results indicate that: by applying the parallel and adaptive uniform-distributed registration method, the efficiency of CE-1 lunar remote sensed imagery registration were increased dramatically. Therefore, the proposed method in the paper could acquire uniform-distributed registration results more effectively, the registration difficulties including difficult to obtain results, time-consuming, non-uniform distribution could be successfully solved.

  10. Usefulness of the classification technique of cerebral artery for 2D/3D registration

    International Nuclear Information System (INIS)

    Takemura, Akihiro; Suzuki, Masayuki; Kikuchi, Yuzo; Okumura, Yusuke; Harauchi, Hajime

    2007-01-01

    Several papers have proposed 2D/3D registration methods of the cerebral artery using magnetic resonance angiography (MRA) and digital subtraction angiography (DSA). Since differences between vessels in a DSA image and MRA volume data cause registration failure, we previously proposed a method to extract vessels from MRA volume data using a technique based on classification of the cerebral artery. In this paper, we evaluated the usefulness of this classification technique by evaluating the reliability of this 2D/3D registration method. This classification method divides the cerebral artery in MRA volume data into 12 segments. According to the results of the classification, structures corresponding to vessels on a DSA image can then be extracted. We applied the 2D/3D registration with/without classification to 16 pairs of MRA volume data and DSA images obtained from six patients. The registration results were scored into four levels (Excellent, Good, Fair and Poor). The rates of successful registration (>fair) were 37.5% for registration without classification and 81.3% for that with classification. These findings suggested that there was a low percentage of incorrectly extracted voxels and we could facilitate reliable registration. Thus, the classification technique was shown to be useful for feature-based 2D/3D registration. (author)

  11. Automated image registration for FDOPA PET studies

    International Nuclear Information System (INIS)

    Kang-Ping Lin; Sung-Cheng Huang, Dan-Chu Yu; Melega, W.; Barrio, J.R.; Phelps, M.E.

    1996-01-01

    In this study, various image registration methods are investigated for their suitability for registration of L-6-[18F]-fluoro-DOPA (FDOPA) PET images. Five different optimization criteria including sum of absolute difference (SAD), mean square difference (MSD), cross-correlation coefficient (CC), standard deviation of pixel ratio (SDPR), and stochastic sign change (SSC) were implemented and Powell's algorithm was used to optimize the criteria. The optimization criteria were calculated either unidirectionally (i.e. only evaluating the criteria for comparing the resliced image 1 with the original image 2) or bidirectionally (i.e. averaging the criteria for comparing the resliced image 1 with the original image 2 and those for the sliced image 2 with the original image 1). Monkey FDOPA images taken at various known orientations were used to evaluate the accuracy of different methods. A set of human FDOPA dynamic images was used to investigate the ability of the methods for correcting subject movement. It was found that a large improvement in performance resulted when bidirectional rather than unidirectional criteria were used. Overall, the SAD, MSD and SDPR methods were found to be comparable in performance and were suitable for registering FDOPA images. The MSD method gave more adequate results for frame-to-frame image registration for correcting subject movement during a dynamic FDOPA study. The utility of the registration method is further demonstrated by registering FDOPA images in monkeys before and after amphetamine injection to reveal more clearly the changes in spatial distribution of FDOPA due to the drug intervention. (author)

  12. Increasing feasibility of the field-programmable gate array implementation of an iterative image registration using a kernel-warping algorithm

    Science.gov (United States)

    Nguyen, An Hung; Guillemette, Thomas; Lambert, Andrew J.; Pickering, Mark R.; Garratt, Matthew A.

    2017-09-01

    Image registration is a fundamental image processing technique. It is used to spatially align two or more images that have been captured at different times, from different sensors, or from different viewpoints. There have been many algorithms proposed for this task. The most common of these being the well-known Lucas-Kanade (LK) and Horn-Schunck approaches. However, the main limitation of these approaches is the computational complexity required to implement the large number of iterations necessary for successful alignment of the images. Previously, a multi-pass image interpolation algorithm (MP-I2A) was developed to considerably reduce the number of iterations required for successful registration compared with the LK algorithm. This paper develops a kernel-warping algorithm (KWA), a modified version of the MP-I2A, which requires fewer iterations to successfully register two images and less memory space for the field-programmable gate array (FPGA) implementation than the MP-I2A. These reductions increase feasibility of the implementation of the proposed algorithm on FPGAs with very limited memory space and other hardware resources. A two-FPGA system rather than single FPGA system is successfully developed to implement the KWA in order to compensate insufficiency of hardware resources supported by one FPGA, and increase parallel processing ability and scalability of the system.

  13. The Homicide Atlas in Colombia: Contagion and Under-Registration for Small Areas

    Directory of Open Access Journals (Sweden)

    B. Piedad Urdinola

    2017-01-01

    Full Text Available The homocide atlas in Colombia is a visual representation of both expansion and aggravation of the armed internal conflict for the deadly decades of 1990 to 2009. However, mortality under-registration remains an issue in most developing countries, more remarkably when studying particular causes of death on small areas. This document proposes a Bayesian spatial method to identify mortality under-registration in municipalities. Probability maps help to identify under-registered municipalities in Colombia that coincide with the rise of violence at the turn of the century, which is not captured in vital registration systems. It also shows that women suffer of higher under-registration issues than men. Corrected homicide Atlases facilitate interpretation and the proposed methodology proves to be a good source of under-registration identification in small populations.

  14. The module of methodical support in system of electronic educational resources as the innovative element of the modern maintenance of formation

    Directory of Open Access Journals (Sweden)

    Ольга Николаевна Крылова

    2009-06-01

    Full Text Available The article introduces some results of research, which were devoted to evaluation of tearches' mobility to introduce innovations in the contents of education. The author considers innovative potential of modules of the methodical support for system of electronic educational resources.

  15. 75 FR 52340 - Fenoxycarb; Notice of Receipt of Request To Voluntarily Cancel Certain Pesticide Registrations

    Science.gov (United States)

    2010-08-25

    ... of Request To Voluntarily Cancel Certain Pesticide Registrations AGENCY: Environmental Protection... registrants to voluntarily cancel registrations of products containing the pesticide fenoxycarb. The request... listed in this notice will be permitted after the registrations have been canceled only if such sale...

  16. 75 FR 28019 - Resmethrin; Notice of Receipt of Requests to Voluntarily Cancel Certain Pesticide Registrations

    Science.gov (United States)

    2010-05-19

    ... of Requests to Voluntarily Cancel Certain Pesticide Registrations AGENCY: Environmental Protection... registrants to voluntarily cancel their registrations of certain products containing the pesticide resmethrin... after the registration has been cancelled only if such sale, distribution, or use is consistent with the...

  17. 16 CFR 1130.6 - Requirements for format of registration forms.

    Science.gov (United States)

    2010-01-01

    ... manufacturer's name and mailing address where registration information is to be collected. (c) Font size and typeface. The registration form shall use bold black typeface. The size of the type shall be at least 12... information shall be in capital and lower case type. ...

  18. 75 FR 76756 - Manufacturer of Controlled Substances; Notice of Registration

    Science.gov (United States)

    2010-12-09

    ..., 2010, (75 FR 47029), Johnson Matthey Pharma Services, 70 Flagship Drive, North Andover, Massachusetts... that the registration of Johnson Matthey Pharma Services to manufacture the listed basic classes of... Matthey Pharma Services to ensure that the company's registration is consistent with the public interest...

  19. 76 FR 51402 - Manufacturer of Controlled Substances; Notice of Registration

    Science.gov (United States)

    2011-08-18

    ..., 2011, 76 FR 25376, Johnson Matthey Pharma Services, 70 Flagship Drive, North Andover, Massachusetts... that the registration of Johnson Matthey Pharma Services to manufacture the listed basic classes of... Matthey Pharma Services to ensure that the company's registration is consistent with the public interest...

  20. Automated analysis of small animal PET studies through deformable registration to an atlas

    International Nuclear Information System (INIS)

    Gutierrez, Daniel F.; Zaidi, Habib

    2012-01-01

    This work aims to develop a methodology for automated atlas-guided analysis of small animal positron emission tomography (PET) data through deformable registration to an anatomical mouse model. A non-rigid registration technique is used to put into correspondence relevant anatomical regions of rodent CT images from combined PET/CT studies to corresponding CT images of the Digimouse anatomical mouse model. The latter provides a pre-segmented atlas consisting of 21 anatomical regions suitable for automated quantitative analysis. Image registration is performed using a package based on the Insight Toolkit allowing the implementation of various image registration algorithms. The optimal parameters obtained for deformable registration were applied to simulated and experimental mouse PET/CT studies. The accuracy of the image registration procedure was assessed by segmenting mouse CT images into seven regions: brain, lungs, heart, kidneys, bladder, skeleton and the rest of the body. This was accomplished prior to image registration using a semi-automated algorithm. Each mouse segmentation was transformed using the parameters obtained during CT to CT image registration. The resulting segmentation was compared with the original Digimouse atlas to quantify image registration accuracy using established metrics such as the Dice coefficient and Hausdorff distance. PET images were then transformed using the same technique and automated quantitative analysis of tracer uptake performed. The Dice coefficient and Hausdorff distance show fair to excellent agreement and a mean registration mismatch distance of about 6 mm. The results demonstrate good quantification accuracy in most of the regions, especially the brain, but not in the bladder, as expected. Normalized mean activity estimates were preserved between the reference and automated quantification techniques with relative errors below 10 % in most of the organs considered. The proposed automated quantification technique is

  1. Automatic Registration of Vehicle-borne Mobile Mapping Laser Point Cloud and Sequent Panoramas

    Directory of Open Access Journals (Sweden)

    CHEN Chi

    2018-02-01

    Full Text Available An automatic registration method of mobile mapping system laser point cloud and sequence panoramic image is proposed in this paper.Firstly,hierarchical object extraction method is applied on LiDAR data to extract the building façade and outline polygons are generated to construct the skyline vectors.A virtual imaging method is proposed to solve the distortion on panoramas and corners on skylines are further detected on the virtual images combining segmentation and corner detection results.Secondly,the detected skyline vectors are taken as the registration primitives.Registration graphs are built according to the extracted skyline vector and further matched under graph edit distance minimization criteria.The matched conjugate primitives are utilized to solve the 2D-3D rough registration model to obtain the initial transformation between the sequence panoramic image coordinate system and the LiDAR point cloud coordinate system.Finally,to reduce the impact of registration primitives extraction and matching error on the registration results,the optimal transformation between the multi view stereo matching dens point cloud generated from the virtual imaging of the sequent panoramas and the LiDAR point cloud are solved by a 3D-3D ICP registration algorithm variant,thus,refine the exterior orientation parameters of panoramas indirectly.Experiments are undertaken to validate the proposed method and the results show that 1.5 pixel level registration results are achieved on the experiment dataset.The registration results can be applied to point cloud and panoramas fusion applications such as true color point cloud generation.

  2. Do Tumors in the Lung Deform During Normal Respiration? An Image Registration Investigation

    International Nuclear Information System (INIS)

    Wu Jianzhou; Lei Peng; Shekhar, Raj; Li Huiling; Suntharalingam, Mohan; D'Souza, Warren D.

    2009-01-01

    Purpose: The purpose of this study was to investigate whether lung tumors may be described adequately using a rigid body assumption or whether they deform during normal respiration. Methods and Materials: Thirty patients with early stage non-small-cell lung cancer underwent four-dimensional (4D) computed tomography (CT) simulation. The gross tumor volume (GTV) was delineated on the 4D CT images. Image registration was performed in the vicinity of the GTV. The volume of interest for registration was the GTV and minimal volume of surrounding non-GTV tissue. Three types of registration were performed: translation only, translation + rotation, and deformable. The GTV contour from end-inhale was mapped to end-exhale using the registration-derived transformation field. The results were evaluated using three metrics: overlap index (OI), root-mean-squared distance (RMS), and Hausdorff distance (HD). Results: After translation only image registration, on average OI increased by 21.3%, RMS and HD reduced by 1.2 mm and 2.0 mm, respectively. The succeeding increases in OI after translation + rotation and deformable registration were 1.1% and 1.4% respectively. The succeeding reductions in RMS were 0.1 mm and 0.2 mm respectively. No reduction in HD was observed after translation + rotation and deformable image registration compared with translation only registration. The difference in the results from the three registration scenarios was independent of GTV size and motion amplitude. Conclusions: The primary effect of normal respiration on lung tumors was the translation of tumors. Rotation and deformation of lung tumors was determined to be minimal.

  3. A new robust markerless method for automatic image-to-patient registration in image-guided neurosurgery system.

    Science.gov (United States)

    Liu, Yinlong; Song, Zhijian; Wang, Manning

    2017-12-01

    Compared with the traditional point-based registration in the image-guided neurosurgery system, surface-based registration is preferable because it does not use fiducial markers before image scanning and does not require image acquisition dedicated for navigation purposes. However, most existing surface-based registration methods must include a manual step for coarse registration, which increases the registration time and elicits some inconvenience and uncertainty. A new automatic surface-based registration method is proposed, which applies 3D surface feature description and matching algorithm to obtain point correspondences for coarse registration and uses the iterative closest point (ICP) algorithm in the last step to obtain an image-to-patient registration. Both phantom and clinical data were used to execute automatic registrations and target registration error (TRE) calculated to verify the practicality and robustness of the proposed method. In phantom experiments, the registration accuracy was stable across different downsampling resolutions (18-26 mm) and different support radii (2-6 mm). In clinical experiments, the mean TREs of two patients by registering full head surfaces were 1.30 mm and 1.85 mm. This study introduced a new robust automatic surface-based registration method based on 3D feature matching. The method achieved sufficient registration accuracy with different real-world surface regions in phantom and clinical experiments.

  4. 2014 Mid-Atlantic Telehealth Resource Center Annual Summit

    Directory of Open Access Journals (Sweden)

    Katharine Hsu Wibberly

    2013-12-01

    Full Text Available The Mid-Atlantic Resource Center (MATRC; http://www.matrc.org/ advances the adoption and utilization of telehealth within the MATRC region and works collaboratively with the other federally funded Telehealth Resource Centers to accomplish the same nationally. MATRC offers technical assistance and other resources within the following mid-Atlantic states: Delaware, District of Columbia, Kentucky, Maryland, North Carolina, Pennsylvania, Virginia and West Virginia.   The 2014 MATRC Summit “Adding Value through Sustainable Telehealth” will be held March 30-April 1, 2014, at the Fredericksburg Expo & Conference Center, Fredericksburg, VA. The Summit will explore how telehealth adds value to patients, practitioners, hospitals, health systems, and other facilities. Participants will experience a highly interactive program built around the case history of “Mr. Doe” as he progresses through the primary care, inpatient hospitalization, and post-discharge environments. The Summit will conclude with a session on financial and business models for providing sustainable telehealth services.   For further information and registration, visit: http://matrc.org/component/content/article/2-uncategorised/80-mid-atlantic-telehealth-resource-summit-2014    

  5. 76 FR 36535 - Dicofol; Notice of Receipt of Request To Voluntarily Cancel Certain Pesticide Registrations

    Science.gov (United States)

    2011-06-22

    ... Request To Voluntarily Cancel Certain Pesticide Registrations AGENCY: Environmental Protection Agency (EPA... registrants to voluntarily cancel their registrations of all products containing the pesticide dicofol. The... the registrations have been cancelled only if such sale, distribution, or use is consistent with the...

  6. 75 FR 22402 - Methyl Parathion; Notice of Receipt of Request to Voluntarily Cancel Pesticide Registrations

    Science.gov (United States)

    2010-04-28

    ... Receipt of Request to Voluntarily Cancel Pesticide Registrations AGENCY: Environmental Protection Agency... registrants to voluntarily cancel their registrations of products containing the pesticide methyl parathion... will be permitted after the registration has been cancelled only if such sale, distribution, or use is...

  7. Image Registration Using Redundant Wavelet Transforms

    National Research Council Canada - National Science Library

    Brown, Richard

    2001-01-01

    .... In our research, we present a fundamentally new wavelet-based registration algorithm utilizing redundant transforms and a masking process to suppress the adverse effects of noise and improve processing efficiency...

  8. Preliminary Studies for a CBCT Imaging Protocol for Offline Organ Motion Analysis: Registration Software Validation and CTDI Measurements

    International Nuclear Information System (INIS)

    Falco, Maria Daniela; Fontanarosa, Davide; Miceli, Roberto; Carosi, Alessandra; Santoni, Riccardo; D'Andrea, Marco

    2011-01-01

    Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4 o . For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22 o ). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be

  9. Impact of Electronic Resources and Usage in Academic Libraries in Ghana: Evidence from Koforidua Polytechnic & All Nations University College, Ghana

    Science.gov (United States)

    Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary

    2015-01-01

    The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…

  10. Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

    International Nuclear Information System (INIS)

    Uemura, K.; Toyama, H.; Miyamoto, T.; Yoshikawa, K.; Mori, Y.

    2002-01-01

    Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images. Materials and Methods: Perfusion, ventilation and blood pool images with Tc 99m labeled radiopharmaceuticals and SPECT, tumor images with 11 C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11 C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively. Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was

  11. 17 CFR 240.15b6-1 - Withdrawal from registration.

    Science.gov (United States)

    2010-04-01

    ... Registration Depository (operated by the Financial Industry Regulatory Authority, Inc.) in accordance with...) to update any inaccurate information. (b) A notice of withdrawal from registration filed by a broker... public interest or for the protection of investors, or within such shorter period of time as the...

  12. What drives Users' Website Registration?

    NARCIS (Netherlands)

    T. Li (Ting); P.A. Pavlou (Paul)

    2013-01-01

    textabstractUser registration is an important prerequisite for the success of many websites by enabling users to gain access to domain information and personalized content. It is not always desirable for users, however, because they need to disclose personal information. This paper examines what

  13. Image Registration Algorithm Based on Parallax Constraint and Clustering Analysis

    Science.gov (United States)

    Wang, Zhe; Dong, Min; Mu, Xiaomin; Wang, Song

    2018-01-01

    To resolve the problem of slow computation speed and low matching accuracy in image registration, a new image registration algorithm based on parallax constraint and clustering analysis is proposed. Firstly, Harris corner detection algorithm is used to extract the feature points of two images. Secondly, use Normalized Cross Correlation (NCC) function to perform the approximate matching of feature points, and the initial feature pair is obtained. Then, according to the parallax constraint condition, the initial feature pair is preprocessed by K-means clustering algorithm, which is used to remove the feature point pairs with obvious errors in the approximate matching process. Finally, adopt Random Sample Consensus (RANSAC) algorithm to optimize the feature points to obtain the final feature point matching result, and the fast and accurate image registration is realized. The experimental results show that the image registration algorithm proposed in this paper can improve the accuracy of the image matching while ensuring the real-time performance of the algorithm.

  14. Using manual prostate contours to enhance deformable registration of endorectal MRI.

    Science.gov (United States)

    Cheung, M R; Krishnan, K

    2012-10-01

    Endorectal MRI provides detailed images of the prostate anatomy and is useful for radiation treatment planning. Here we describe a Demons field-initialized B-spline deformable registration of prostate MRI. T2-weighted endorectal MRIs of five patients were used. The prostate and the tumor of each patient were manually contoured. The planning MRIs and their segmentations were simulated by warping the corresponding endorectal MRIs using thin plate spline (TPS). Deformable registration was initialized using the deformation field generated using Demons algorithm to map the deformed prostate MRI to the non-deformed one. The solution was refined with B-Spline registration. Volume overlap similarity was used to assess the accuracy of registration and to suggest a minimum margin to account for the registration errors. Initialization using Demons algorithm took about 15 min on a computer with 2.8 GHz Intel, 1.3 GB RAM. Refinement B-spline registration (200 iterations) took less than 5 min. Using the synthetic images as the ground truth, at zero margin, the average (S.D.) 98 (±0.4)% for prostate coverage was 97 (±1)% for tumor. The average (±S.D.) treatment margin required to cover the entire prostate was 1.5 (±0.2)mm. The average (± S.D.) treatment margin required to cover the tumor was 0.7 (±0.1)mm. We also demonstrated the challenges in registering an in vivo deformed MRI to an in vivo non-deformed MRI. We here present a deformable registration scheme that can overcome large deformation. This platform is expected to be useful for prostate cancer radiation treatment planning. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. CO-REGISTRATION OF PHOTOGRAMMETRIC AND LIDAR DATA: METHODOLOGY AND CASE STUDY

    Directory of Open Access Journals (Sweden)

    Mwafag Ghanma

    2004-07-01

    Full Text Available Registration activities combine data from different sources in order to attain higher accuracy and derive more information than available from one source. The increasing availability of a wide variety of sensors capable of capturing high quality and complementary data requires parallel efforts for developing accurate and robust registration techniques. Currently, photogrammetric and LIDAR systems are being incorporated in a wide spectrum of mapping applica¬tions such as city modeling, surface reconstruction, and object recognition. Photogrammetric processing of overlapping imagery provides accurate information regarding object space break-lines in addition to an explicit semantic description of the photographed objects. On the other hand, LIDAR systems supply dense geometric surface information in the form of non-selective points. Considering the properties of photogrammetric and LIDAR data, it is clear that the two technologies provide complementary information. However, the synergic characteristics of both systems can be fully utilized only after successful registration of the photogrammetric and LIDAR data relative to a common reference frame. The registration methodology has to deal with three issues: registration primitives, transformation function, and similarity measure. This paper presents two methodologies for utilizing straight-line features derived from both datasets as the registration primitives. The first methodology directly incorporates the LIDAR lines as control information in the photogrammetric triangulation. The second methodology starts by generating a photogrammetric model relative to an arbitrary datum. Then, LIDAR features are used as control information for the absolute orientation of the photogram¬metric model. In addition to the registration methodologies, the paper presents a comparative analysis between two approaches for extracting linear features from raw and processed/interpolated LIDAR data. Also, a comparative

  16. Monitoring tumor motion by real time 2D/3D registration during radiotherapy.

    Science.gov (United States)

    Gendrin, Christelle; Furtado, Hugo; Weber, Christoph; Bloch, Christoph; Figl, Michael; Pawiro, Supriyanto Ardjo; Bergmann, Helmar; Stock, Markus; Fichtinger, Gabor; Georg, Dietmar; Birkfellner, Wolfgang

    2012-02-01

    In this paper, we investigate the possibility to use X-ray based real time 2D/3D registration for non-invasive tumor motion monitoring during radiotherapy. The 2D/3D registration scheme is implemented using general purpose computation on graphics hardware (GPGPU) programming techniques and several algorithmic refinements in the registration process. Validation is conducted off-line using a phantom and five clinical patient data sets. The registration is performed on a region of interest (ROI) centered around the planned target volume (PTV). The phantom motion is measured with an rms error of 2.56 mm. For the patient data sets, a sinusoidal movement that clearly correlates to the breathing cycle is shown. Videos show a good match between X-ray and digitally reconstructed radiographs (DRR) displacement. Mean registration time is 0.5 s. We have demonstrated that real-time organ motion monitoring using image based markerless registration is feasible. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. DESIGN OF A COUNTABLE PROCEDURE FOR THE REGISTRATION OF ENVIRONMENTAL VARIABLES

    Directory of Open Access Journals (Sweden)

    Elier Eugenio Rabanal-Arencibia

    2016-01-01

    Full Text Available Many companies present in their memoirs matters of environmental character, but they are few those that are able to count the environmental facts that definitively influence in their financial states. One of the challenges of our managerial sector in Cuba is to integrate the topic of the environment to the process of taking decisions and to the business strategies. A countable system that contemplates the environmental concept in its classifier of bills, obviously will have available information for its costs and environmental revenues, what is indispensable in the long term company development, especially if it is about companies related with the exploitation of natural resources. The purpose is to carry out the Design of a Countable Procedure for the registration of environmental variables, as a support to the continuous improvement of the Environmental Accounting. 

  18. Spatially weighted mutual information image registration for image guided radiation therapy

    International Nuclear Information System (INIS)

    Park, Samuel B.; Rhee, Frank C.; Monroe, James I.; Sohn, Jason W.

    2010-01-01

    Purpose: To develop a new metric for image registration that incorporates the (sub)pixelwise differential importance along spatial location and to demonstrate its application for image guided radiation therapy (IGRT). Methods: It is well known that rigid-body image registration with mutual information is dependent on the size and location of the image subset on which the alignment analysis is based [the designated region of interest (ROI)]. Therefore, careful review and manual adjustments of the resulting registration are frequently necessary. Although there were some investigations of weighted mutual information (WMI), these efforts could not apply the differential importance to a particular spatial location since WMI only applies the weight to the joint histogram space. The authors developed the spatially weighted mutual information (SWMI) metric by incorporating an adaptable weight function with spatial localization into mutual information. SWMI enables the user to apply the selected transform to medically ''important'' areas such as tumors and critical structures, so SWMI is neither dominated by, nor neglects the neighboring structures. Since SWMI can be utilized with any weight function form, the authors presented two examples of weight functions for IGRT application: A Gaussian-shaped weight function (GW) applied to a user-defined location and a structures-of-interest (SOI) based weight function. An image registration example using a synthesized 2D image is presented to illustrate the efficacy of SWMI. The convergence and feasibility of the registration method as applied to clinical imaging is illustrated by fusing a prostate treatment planning CT with a clinical cone beam CT (CBCT) image set acquired for patient alignment. Forty-one trials are run to test the speed of convergence. The authors also applied SWMI registration using two types of weight functions to two head and neck cases and a prostate case with clinically acquired CBCT/MVCT image sets. The

  19. Spatially weighted mutual information image registration for image guided radiation therapy.

    Science.gov (United States)

    Park, Samuel B; Rhee, Frank C; Monroe, James I; Sohn, Jason W

    2010-09-01

    To develop a new metric for image registration that incorporates the (sub)pixelwise differential importance along spatial location and to demonstrate its application for image guided radiation therapy (IGRT). It is well known that rigid-body image registration with mutual information is dependent on the size and location of the image subset on which the alignment analysis is based [the designated region of interest (ROI)]. Therefore, careful review and manual adjustments of the resulting registration are frequently necessary. Although there were some investigations of weighted mutual information (WMI), these efforts could not apply the differential importance to a particular spatial location since WMI only applies the weight to the joint histogram space. The authors developed the spatially weighted mutual information (SWMI) metric by incorporating an adaptable weight function with spatial localization into mutual information. SWMI enables the user to apply the selected transform to medically "important" areas such as tumors and critical structures, so SWMI is neither dominated by, nor neglects the neighboring structures. Since SWMI can be utilized with any weight function form, the authors presented two examples of weight functions for IGRT application: A Gaussian-shaped weight function (GW) applied to a user-defined location and a structures-of-interest (SOI) based weight function. An image registration example using a synthesized 2D image is presented to illustrate the efficacy of SWMI. The convergence and feasibility of the registration method as applied to clinical imaging is illustrated by fusing a prostate treatment planning CT with a clinical cone beam CT (CBCT) image set acquired for patient alignment. Forty-one trials are run to test the speed of convergence. The authors also applied SWMI registration using two types of weight functions to two head and neck cases and a prostate case with clinically acquired CBCT/ MVCT image sets. The SWMI registration with

  20. 76 FR 10587 - Product Cancellation Order for Certain Pesticide Registrations

    Science.gov (United States)

    2011-02-25

    ...-00160 Unicorn House and Phenothrin Carpet Spray 11. Tetramethrin 028293-00215 Unicorn IGR Phenothrin... company number. This number corresponds to the first part of the EPA registration numbers of the products listed in this unit. Table 4 --Registrants of Cancelled Products Company No. Company name and address 192...

  1. 21 CFR 1309.44 - Suspension of registration pending final order.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Suspension of registration pending final order. 1309.44 Section 1309.44 Food and Drugs DRUG ENFORCEMENT ADMINISTRATION, DEPARTMENT OF JUSTICE... pending final order. (a) The Administrator may suspend any registration simultaneously with or at any time...

  2. 37 CFR 2.181 - Term of original registrations and renewals.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Term of original registrations and renewals. 2.181 Section 2.181 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND... of original registrations and renewals. (a)(1) Subject to the provisions of section 8 of the Act...

  3. The dispense of legal reserve in the registration of property: decrease of environmental protection?

    Directory of Open Access Journals (Sweden)

    Thiago de Miranda Carneiro

    2016-12-01

    Full Text Available It is intended to analyze the rural environmental registry and exemption from the registration of the legal reserve on the basis of Law 12.651/12. They will be addressed elements of environmental protection and real estate to handle the revocation of registration of the legal reserve in real estate registry and their inclusion in the CAR, as well as property registration paper and registral advertising in order to ascertain the legal traffic safety real estate. We used exploratory method  through literature and document analysis starting at the constitutional and environmental law through the registral law.

  4. Evaluation of whole-body MR to CT deformable image registration.

    Science.gov (United States)

    Akbarzadeh, A; Gutierrez, D; Baskin, A; Ay, M R; Ahmadian, A; Riahi Alam, N; Lövblad, K O; Zaidi, H

    2013-07-08

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based on B-spline transformation was performed using optimized parameters of the elastix package based on the Insight Toolkit (ITK) framework. Twenty-eight (17 male and 11 female) clinical studies were used in this work. The registration was evaluated using anatomical landmarks and segmented organs. In addition to 16 anatomical landmarks, three key organs (brain, lungs, and kidneys) and the entire body volume were segmented for evaluation. Several parameters--such as the Euclidean distance between anatomical landmarks, target overlap, Dice and Jaccard coefficients, false positives and false negatives, volume similarity, distance error, and Hausdorff distance--were calculated to quantify the quality of the registration algorithm. Dice coefficients for the majority of patients (> 75%) were in the 0.8-1 range for the whole body, brain, and lungs, which satisfies the criteria to achieve excellent alignment. On the other hand, for kidneys, Dice coefficients for volumes of 25% of the patients meet excellent volume agreement requirement, while the majority of patients satisfy good agreement criteria (> 0.6). For all patients, the distance error was in 0-10 mm range for all segmented organs. In summary, we optimized and evaluated the accuracy of an MR to CT deformable registration algorithm. The registered images constitute a useful 3D whole-body MR-CT atlas suitable for the development and evaluation of novel MR-guided attenuation correction procedures on hybrid PET-MR systems.

  5. Optimal full motion video registration with rigorous error propagation

    Science.gov (United States)

    Dolloff, John; Hottel, Bryant; Doucette, Peter; Theiss, Henry; Jocher, Glenn

    2014-06-01

    Optimal full motion video (FMV) registration is a crucial need for the Geospatial community. It is required for subsequent and optimal geopositioning with simultaneous and reliable accuracy prediction. An overall approach being developed for such registration is presented that models relevant error sources in terms of the expected magnitude and correlation of sensor errors. The corresponding estimator is selected based on the level of accuracy of the a priori information of the sensor's trajectory and attitude (pointing) information, in order to best deal with non-linearity effects. Estimator choices include near real-time Kalman Filters and batch Weighted Least Squares. Registration solves for corrections to the sensor a priori information for each frame. It also computes and makes available a posteriori accuracy information, i.e., the expected magnitude and correlation of sensor registration errors. Both the registered sensor data and its a posteriori accuracy information are then made available to "down-stream" Multi-Image Geopositioning (MIG) processes. An object of interest is then measured on the registered frames and a multi-image optimal solution, including reliable predicted solution accuracy, is then performed for the object's 3D coordinates. This paper also describes a robust approach to registration when a priori information of sensor attitude is unavailable. It makes use of structure-from-motion principles, but does not use standard Computer Vision techniques, such as estimation of the Essential Matrix which can be very sensitive to noise. The approach used instead is a novel, robust, direct search-based technique.

  6. Utilization of Electronic Information Resources by Undergraduate Students of University of Ibadan: A Case Study of Social Sciences and Education

    Science.gov (United States)

    Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo

    2016-01-01

    The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…

  7. 31 CFR 357.21 - Registration.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Registration. 357.21 Section 357.21 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL SERVICE... other private corporation must be followed by descriptive words indicating the corporate status unless...

  8. Shaping the Electronic Library--The UW-Madison Approach.

    Science.gov (United States)

    Dean, Charles W., Ed.; Frazier, Ken; Pope, Nolan F.; Gorman, Peter C.; Dentinger, Sue; Boston, Jeanne; Phillips, Hugh; Daggett, Steven C.; Lundquist, Mitch; McClung, Mark; Riley, Curran; Allan, Craig; Waugh, David

    1998-01-01

    This special theme section describes the University of Wisconsin-Madison's experience building its Electronic Library. Highlights include integrating resources and services; the administrative framework; the public electronic library, including electronic publishing capability and access to World Wide Web-based and other electronic resources;…

  9. Significantly reducing registration time in IGRT using graphics processing units

    DEFF Research Database (Denmark)

    Noe, Karsten Østergaard; Denis de Senneville, Baudouin; Tanderup, Kari

    2008-01-01

    respiration phases in a free breathing volunteer and 41 anatomical landmark points in each image series. The registration method used is a multi-resolution GPU implementation of the 3D Horn and Schunck algorithm. It is based on the CUDA framework from Nvidia. Results On an Intel Core 2 CPU at 2.4GHz each...... registration took 30 minutes. On an Nvidia Geforce 8800GTX GPU in the same machine this registration took 37 seconds, making the GPU version 48.7 times faster. The nine image series of different respiration phases were registered to the same reference image (full inhale). Accuracy was evaluated on landmark...

  10. 46 CFR Exhibit 1 to Part 530 - Service Contract Registration [Form FMC-83

    Science.gov (United States)

    2010-10-01

    .... Registrant. This must be the full legal name of the firm or individual registering for the FMC's Service Contract Filing System and any trade names. The registrant name should match the corporate charter or business license, conference membership, etc. It should be noted that the registrant name cannot be changed...

  11. 76 FR 16415 - Product Cancellation Order for Certain Pesticide Registrations

    Science.gov (United States)

    2011-03-23

    ...-00050 1% Rotenone Garden Dust Rotenone Cube Resins other than rotenone. 028293-00042 Unicorn Ear Mite... registrants of the products in Table 1 of this unit, in sequence by EPA company number. This number.... Table 2--Registrants of Canceled Products EPA company No. Company name and address 4 Bonide Products...

  12. 9 CFR 121.7 - Registration and related security risk assessments.

    Science.gov (United States)

    2010-01-01

    ... the entity if the individual is in a managerial or executive capacity with regard to the entity's... managerial or executive capacity with regard to the entity's select agents or toxins or with regard to the...) of the registration application. (f) The issuance of a certificate of registration may be contingent...

  13. A MRI-CT prostate registration using sparse representation technique

    Science.gov (United States)

    Yang, Xiaofeng; Jani, Ashesh B.; Rossi, Peter J.; Mao, Hui; Curran, Walter J.; Liu, Tian

    2016-03-01

    Purpose: To develop a new MRI-CT prostate registration using patch-based deformation prediction framework to improve MRI-guided prostate radiotherapy by incorporating multiparametric MRI into planning CT images. Methods: The main contribution is to estimate the deformation between prostate MRI and CT images in a patch-wise fashion by using the sparse representation technique. We assume that two image patches should follow the same deformation if their patch-wise appearance patterns are similar. Specifically, there are two stages in our proposed framework, i.e., the training stage and the application stage. In the training stage, each prostate MR images are carefully registered to the corresponding CT images and all training MR and CT images are carefully registered to a selected CT template. Thus, we obtain the dense deformation field for each training MR and CT image. In the application stage, for registering a new subject MR image with the same subject CT image, we first select a small number of key points at the distinctive regions of this subject CT image. Then, for each key point in the subject CT image, we extract the image patch, centered at the underlying key point. Then, we adaptively construct the coupled dictionary for the underlying point where each atom in the dictionary consists of image patches and the respective deformations obtained from training pair-wise MRI-CT images. Next, the subject image patch can be sparsely represented by a linear combination of training image patches in the dictionary, where we apply the same sparse coefficients to the respective deformations in the dictionary to predict the deformation for the subject MR image patch. After we repeat the same procedure for each subject CT key point, we use B-splines to interpolate a dense deformation field, which is used as the initialization to allow the registration algorithm estimating the remaining small segment of deformations from MRI to CT image. Results: Our MRI-CT registration

  14. High-Throughput Printing Process for Flexible Electronics

    Science.gov (United States)

    Hyun, Woo Jin

    Printed electronics is an emerging field for manufacturing electronic devices with low cost and minimal material waste for a variety of applications including displays, distributed sensing, smart packaging, and energy management. Moreover, its compatibility with roll-to-roll production formats and flexible substrates is desirable for continuous, high-throughput production of flexible electronics. Despite the promise, however, the roll-to-roll production of printed electronics is quite challenging due to web movement hindering accurate ink registration and high-fidelity printing. In this talk, I will present a promising strategy for roll-to-roll production using a novel printing process that we term SCALE (Self-aligned Capillarity-Assisted Lithography for Electronics). By utilizing capillarity of liquid inks on nano/micro-structured substrates, the SCALE process facilitates high-resolution and self-aligned patterning of electrically functional inks with greatly improved printing tolerance. I will show the fabrication of key building blocks (e.g. transistor, resistor, capacitor) for electronic circuits using the SCALE process on plastics.

  15. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2017-08-22

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes obtaining an image from a communication device of a user. An individual and a landmark are identified within the image. Determinations are made that the individual is the user and that the landmark is a predetermined landmark. Access to a restricted computing resource is granted based on the determining that the individual is the user and that the landmark is the predetermined landmark. Other embodiments are disclosed.

  16. The use of quality benchmarking in assessing web resources for the dermatology virtual branch library of the National electronic Library for Health (NeLH).

    Science.gov (United States)

    Kamel Boulos, M N; Roudsari, A V; Gordon, C; Muir Gray, J A

    2001-01-01

    In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health. They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health. It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for

  17. Improving fluid registration through white matter segmentation in a twin study design

    Science.gov (United States)

    Chou, Yi-Yu; Lepore, Natasha; Brun, Caroline; Barysheva, Marina; McMahon, Katie; de Zubicaray, Greig I.; Wright, Margaret J.; Toga, Arthur W.; Thompson, Paul M.

    2010-03-01

    Robust and automatic non-rigid registration depends on many parameters that have not yet been systematically explored. Here we determined how tissue classification influences non-linear fluid registration of brain MRI. Twin data is ideal for studying this question, as volumetric correlations between corresponding brain regions that are under genetic control should be higher in monozygotic twins (MZ) who share 100% of their genes when compared to dizygotic twins (DZ) who share half their genes on average. When these substructure volumes are quantified using tensor-based morphometry, improved registration can be defined based on which method gives higher MZ twin correlations when compared to DZs, as registration errors tend to deplete these correlations. In a study of 92 subjects, higher effect sizes were found in cumulative distribution functions derived from statistical maps when performing tissue classification before fluid registration, versus fluidly registering the raw images. This gives empirical evidence in favor of pre-segmenting images for tensor-based morphometry.

  18. The perceived impact of the European registration system for genetic counsellors and nurses.

    Science.gov (United States)

    Paneque, Milena; Moldovan, Ramona; Cordier, Christophe; Serra-Juhé, Clara; Feroce, Irene; Pasalodos, Sara; Haquet, Emmanuelle; Lambert, Debby; Bjørnevoll, Inga; Skirton, Heather

    2017-09-01

    The aim of the European Board of Medical Genetics has been to develop and promote academic and professional standards necessary in order to provide competent genetic counselling services. The aim of this study was to explore the impact of the European registration system for genetic nurses and counsellors from the perspectives of those professionals who have registered. Registration system was launched in 2013. A cross-sectional, online survey was used to explore the motivations and experiences of those applying for, and the effect of registration on their career. Fifty-five Genetic Nurses and Counsellors are registered till now, from them, thirty-three agreed to participate on this study. The main motivations for registering were for recognition of their work value and competence (30.3%); due to the absence of a registration system in their own country (15.2%) and the possibility of obtaining a European/international certification (27.3%), while 27.3% of respondents registered to support recognition of the genetic counselling profession. Some participants valued the registration process as an educational activity in its own right, while the majority indicated the greatest impact of the registration process was on their clinical practice. The results confirm that registrants value the opportunity to both confirm their own competence and advance the genetic counselling profession in Europe.

  19. INVITED REVIEW--IMAGE REGISTRATION IN VETERINARY RADIATION ONCOLOGY: INDICATIONS, IMPLICATIONS, AND FUTURE ADVANCES.

    Science.gov (United States)

    Feng, Yang; Lawrence, Jessica; Cheng, Kun; Montgomery, Dean; Forrest, Lisa; Mclaren, Duncan B; McLaughlin, Stephen; Argyle, David J; Nailon, William H

    2016-01-01

    The field of veterinary radiation therapy (RT) has gained substantial momentum in recent decades with significant advances in conformal treatment planning, image-guided radiation therapy (IGRT), and intensity-modulated (IMRT) techniques. At the root of these advancements lie improvements in tumor imaging, image alignment (registration), target volume delineation, and identification of critical structures. Image registration has been widely used to combine information from multimodality images such as computerized tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) to improve the accuracy of radiation delivery and reliably identify tumor-bearing areas. Many different techniques have been applied in image registration. This review provides an overview of medical image registration in RT and its applications in veterinary oncology. A summary of the most commonly used approaches in human and veterinary medicine is presented along with their current use in IGRT and adaptive radiation therapy (ART). It is important to realize that registration does not guarantee that target volumes, such as the gross tumor volume (GTV), are correctly identified on the image being registered, as limitations unique to registration algorithms exist. Research involving novel registration frameworks for automatic segmentation of tumor volumes is ongoing and comparative oncology programs offer a unique opportunity to test the efficacy of proposed algorithms. © 2016 American College of Veterinary Radiology.

  20. Non-rigid image registration using bone growth model

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Gramkow, Claus; Kreiborg, Sven

    1997-01-01

    Non-rigid registration has traditionally used physical models like elasticity and fluids. These models are very seldom valid models of the difference between the registered images. This paper presents a non-rigid registration algorithm, which uses a model of bone growth as a model of the change...... between time sequence images of the human mandible. By being able to register the images, this paper at the same time contributes to the validation of the growth model, which is based on the currently available medical theories and knowledge...