WorldWideScience

Sample records for regional pixe facility

  1. PIXE facility at Centro Atomico Bariloche

    Energy Technology Data Exchange (ETDEWEB)

    Limandri, S.; Rodriguez, L. [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina); Olivares, C.; Bernardi, G. [Centro Atomico Bariloche, Comision Nacional de Energia Atomica, San Carlos de Bariloche, Rio Negro (Argentina); Suarez, S. [lnstituto Balseiro, Universidad Nacional de Cuyo, San Carlos de Bariloche, Rio Negro (Argentina)

    2013-07-01

    Full text: A Tandem accelerator, NEC Pelletron 5SDH, has been recently installed at Centro Atomico Bariloche, Argentina. This facility provides the local scientific community the opportunity to use nuclear techniques in different fields such as material science, environment (air, soil and food), biology, archaeology, etc.). The ion beam techniques available in our laboratory includes the ones commonly used in material analysis, i. e., PIXE (proton induced X-ray emission), RBS (Rutherford backscattering spectroscopy), PIGE (proton induced gamma ray emission), channeling and ERDA (elastic recall detection analysis). The line used for material analysis consists of a NEC-RC43 Endstation with setups and detectors for all the techniques above mentioned. This communication includes a description of the system facility and the main associated equipment, in particular that for PIXE measurements. In addition, we show some recent applications of PIXE to the study of archaeological ceramics, smokeless gun powders, and the experimental determination of the efficiency or our SDD detector. The detector efficiency was estimated for energies between 0.27 and 25 keV. The method applied is based on the comparison of X-ray characteristic intensities excited by 2-MeV protons in bulk samples with theoretical predictions. The results are compared with efficiency values obtained by the product of the window transmission and the detector quantum efficiency. Element constituents of black, white, brown and ocher pigments from Aguada Culture (600-900 before present) were studied. The results obtained are compared with measurements performed at the Laboratorio de Implantacao Ionica-UFRGS. This study is helpful to interpret the social, political economic and cultural contexts of pre-Inca societies and the interaction among different sites. Traces amounts present in seven smokeless gun powders commonly used in Argentina were determined. The powders were deposited on a carbon tape and the

  2. PIXE facility at Centro Atomico Bariloche

    International Nuclear Information System (INIS)

    Limandri, S.; Rodriguez, L.; Olivares, C.; Bernardi, G.; Suarez, S.

    2013-01-01

    Full text: A Tandem accelerator, NEC Pelletron 5SDH, has been recently installed at Centro Atomico Bariloche, Argentina. This facility provides the local scientific community the opportunity to use nuclear techniques in different fields such as material science, environment (air, soil and food), biology, archaeology, etc.). The ion beam techniques available in our laboratory includes the ones commonly used in material analysis, i. e., PIXE (proton induced X-ray emission), RBS (Rutherford backscattering spectroscopy), PIGE (proton induced gamma ray emission), channeling and ERDA (elastic recall detection analysis). The line used for material analysis consists of a NEC-RC43 Endstation with setups and detectors for all the techniques above mentioned. This communication includes a description of the system facility and the main associated equipment, in particular that for PIXE measurements. In addition, we show some recent applications of PIXE to the study of archaeological ceramics, smokeless gun powders, and the experimental determination of the efficiency or our SDD detector. The detector efficiency was estimated for energies between 0.27 and 25 keV. The method applied is based on the comparison of X-ray characteristic intensities excited by 2-MeV protons in bulk samples with theoretical predictions. The results are compared with efficiency values obtained by the product of the window transmission and the detector quantum efficiency. Element constituents of black, white, brown and ocher pigments from Aguada Culture (600-900 before present) were studied. The results obtained are compared with measurements performed at the Laboratorio de Implantacao Ionica-UFRGS. This study is helpful to interpret the social, political economic and cultural contexts of pre-Inca societies and the interaction among different sites. Traces amounts present in seven smokeless gun powders commonly used in Argentina were determined. The powders were deposited on a carbon tape and the

  3. Programs for visualization, handling and quantification of PIXE maps at the AGLAE facility

    Energy Technology Data Exchange (ETDEWEB)

    Pichon, L., E-mail: laurent.pichon@culture.fr [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France); Calligaro, T. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France); PSL Research University, Chimie ParisTech-CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Lemasson, Q.; Moignard, B.; Pacheco, C. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS, Ministère de la Culture et de la Communication, Chimie ParisTech, Palais du Louvre, 75001 Paris (France)

    2015-11-15

    The external beam setup of the AGLAE facility has been developed in order to combine PIXE with PIGE, EBS and recently IBIL for the analysis of cultural heritage artefacts. The upgraded external beam end-station integrates five large solid angle X-ray detectors either to reduce the risk of damage on sensitive artworks by decreasing the beam intensity or to routinely acquire elemental maps at various scales. While many programs are available to process PIXE maps acquired with nuclear microprobes, a software to process the major and trace elements PIXE maps point by point using GUPIX is not available. The present paper describes three programs developed for the AGLAE facility to process numerous maps obtained with multiple detectors. AGLAEMAP allows to handle maps and pixel groups within maps, TRAUPIXE to process quantitatively PIXE spectra of all pixels and DATAIMAGING to display the resulting quantitative elemental maps. The benefits of this software suite are demonstrated by processing a dataset acquired on a pellet of geostandard reference material and on a terre mêlée pottery shard sample created by the famous ceramist Bernard Palissy (1510–1589), highlighting chemical elements present in this polychrome ceramic.

  4. Programs for visualization, handling and quantification of PIXE maps at the AGLAE facility

    International Nuclear Information System (INIS)

    Pichon, L.; Calligaro, T.; Lemasson, Q.; Moignard, B.; Pacheco, C.

    2015-01-01

    The external beam setup of the AGLAE facility has been developed in order to combine PIXE with PIGE, EBS and recently IBIL for the analysis of cultural heritage artefacts. The upgraded external beam end-station integrates five large solid angle X-ray detectors either to reduce the risk of damage on sensitive artworks by decreasing the beam intensity or to routinely acquire elemental maps at various scales. While many programs are available to process PIXE maps acquired with nuclear microprobes, a software to process the major and trace elements PIXE maps point by point using GUPIX is not available. The present paper describes three programs developed for the AGLAE facility to process numerous maps obtained with multiple detectors. AGLAEMAP allows to handle maps and pixel groups within maps, TRAUPIXE to process quantitatively PIXE spectra of all pixels and DATAIMAGING to display the resulting quantitative elemental maps. The benefits of this software suite are demonstrated by processing a dataset acquired on a pellet of geostandard reference material and on a terre mêlée pottery shard sample created by the famous ceramist Bernard Palissy (1510–1589), highlighting chemical elements present in this polychrome ceramic.

  5. PIXE facility at Centro Atómico Bariloche

    Energy Technology Data Exchange (ETDEWEB)

    Limandri, S. [Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina (CONICET) (Argentina); Olivares, C. [Centro Atómico Bariloche, Comisión Nacional de Energía Atómica, Av. E. Bustillo 9500, San Carlos de Bariloche, Río Negro (Argentina); Rodriguez, L. [Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina (CONICET) (Argentina); Bernardi, G. [Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina (CONICET) (Argentina); Centro Atómico Bariloche, Comisión Nacional de Energía Atómica, Av. E. Bustillo 9500, San Carlos de Bariloche, Río Negro (Argentina); Suárez, S., E-mail: suarez@cab.cnea.gov.ar [Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina (CONICET) (Argentina); Instituto Balseiro, Universidad Nacional de Cuyo, Av. E. Bustillo 9500, San Carlos de Bariloche, Río Negro (Argentina)

    2014-01-01

    A 1.7 MeV tandem accelerator has been recently installed at Centro Atómico Bariloche, Argentina. This communication includes a brief description of the system facility with the main associated equipment, in particular that used for PIXE measurements. The X-ray detector efficiency was experimentally determined by comparing X-ray characteristic spectra with theoretical predictions. The knowledge of this parameter allows us to perform quantification without standards with good precision. We show some recent applications of PIXE in archaeology and forensic science done at our laboratory. In the archaeological field we determined elements constituent of pastes and black, white, brown and ocher pigments from Aguada Portezuelo Culture (600–900 AD). This study allowed us to infer about the presence of psilomelante mineral (a mineral with barium) as precursor of some black pigments. In the forensic field we determined trace elements that are present in seven gunpowders commonly used in Argentina. We note that any gunpowder can be distinguished by the presence of trace elements.

  6. Setting up of a PIXE facility at FOTIA at BARC

    International Nuclear Information System (INIS)

    Joseph, Daisy; Saxena, A.

    2005-01-01

    PIXE-(Proton Induced X-ray Emission) -an ideal technique for material characterization has been set up at the Folded Tandem Ion Accelerator (FOTIA) at BARC, Trombay. A separate beam line at 45 deg port in which a dedicated PIXE chamber has been installed is being used for PIXE studies. PIXE studies on gold standards were carried out using protons of energy 3.3 MeV. Caritage values of gold standards were obtained which agree well with the certified values. Single element standard solutions (100 μg/ml) for low-Z elements such as Cr, Mn, Fe, Co, Cu and Zn were analyzed by PIXE. Well resolved α and β components of the x-rays were seen with detection limits in the range of 0.8-4 μg/g. (author)

  7. Turbo Pascal Computer Code for PIXE Analysis

    International Nuclear Information System (INIS)

    Darsono

    2002-01-01

    To optimal utilization of the 150 kV ion accelerator facilities and to govern the analysis technique using ion accelerator, the research and development of low energy PIXE technology has been done. The R and D for hardware of the low energy PIXE installation in P3TM have been carried on since year 2000. To support the R and D of PIXE accelerator facilities in harmonize with the R and D of the PIXE hardware, the development of PIXE software for analysis is also needed. The development of database of PIXE software for analysis using turbo Pascal computer code is reported in this paper. This computer code computes the ionization cross-section, the fluorescence yield, and the stopping power of elements also it computes the coefficient attenuation of X- rays energy. The computer code is named PIXEDASIS and it is part of big computer code planed for PIXE analysis that will be constructed in the near future. PIXEDASIS is designed to be communicative with the user. It has the input from the keyboard. The output shows in the PC monitor, which also can be printed. The performance test of the PIXEDASIS shows that it can be operated well and it can provide data agreement with data form other literatures. (author)

  8. Network application of PIXE trace element analysis

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Hattori, T.

    2003-01-01

    Particle Induced X-ray Emission (PIXE) is a very sensitive analytical technique for determinations of trace elements. But the number of users is limited because there are not so much accelerators which can be used easily. On the other hand, PIXE is a typical machine analysis which can easily analyze automatically and make online data acquisition system. If there is useful online data handling system then PIXE analysis should be more useful for many persons. Therefore we develop to online PIXE facility at Tokyo Institute of Technology VdG laboratory and use it for environmental educations. (author)

  9. External beam PIXE analysis of painting

    International Nuclear Information System (INIS)

    Pascholati, Paulo R.; Rizzutto, Marcia A.; Barbosa, Marcel D.L.; Albuquerque, Cindy

    2005-01-01

    The preservation and conservation of mankind cultural heritage has become an important issue worldwide. Non-destructive analytical techniques are suitable, for example, to analyze precious and unique objects of art and archaeology. Among those techniques Particle Induced X-Ray Emission (PIXE) has good advantage to identify elemental composition present in these kinds of objects. The Laboratorio de Analise de Materiais por Feixes Ionicos-LAMFI of the Institute of Physics of the University of Sao Paulo has been installed an external beam facility for PIXE analysis. This new setup is being used for the analysis of archaeological pottery artifacts, paintings and biological tissues (teeth and bones), which are not compatible with the high vacuum of the regular PIXE target chamber. In addition most art and archaeological objects are too large for the evacuated analysis chamber. Applications of this facility will be presented in the analysis of one painting of the beginning of the last century. The chemical elements identified in the painting were Ca, Ti, Cr, Cu, Fe, Zn, Pb and Ba. The PIXE measurements were done non-destructively and no visible damage was observed on the irradiated object. (author)

  10. The PixFEL project: Progress towards a fine pitch X-ray imaging camera for next generation FEL facilities

    Energy Technology Data Exchange (ETDEWEB)

    Rizzo, G., E-mail: giuliana.rizzo@pi.infn.it [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Batignani, G. [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Benkechkache, M.A. [Università di Trento, Dipartimento di Ingegneria Industriale, I-38123 Trento (Italy); University Constantine 1, Department of Electronics in the Science and Technology Faculty, I-25017, Constantine (Algeria); Bettarini, S.; Casarosa, G. [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Comotti, D. [Università di Pavia, Dipartimento di Ingegneria Industriale e dell' Informazione, I-27100 Pavia (Italy); INFN Sezione di Pavia, I-27100 Pavia (Italy); Dalla Betta, G.-F. [Università di Trento, Dipartimento di Ingegneria Industriale, I-38123 Trento (Italy); TIFPA INFN, I-38123 Trento (Italy); Fabris, L. [INFN Sezione di Pavia, I-27100 Pavia (Italy); Università di Bergamo, Dipartimento di Ingegneria e Scienze Applicate, I-24044 Dalmine (Italy); Forti, F. [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Grassi, M.; Lodola, L.; Malcovati, P. [Università di Pavia, Dipartimento di Ingegneria Industriale e dell' Informazione, I-27100 Pavia (Italy); INFN Sezione di Pavia, I-27100 Pavia (Italy); Manghisoni, M. [INFN Sezione di Pavia, I-27100 Pavia (Italy); Università di Bergamo, Dipartimento di Ingegneria e Scienze Applicate, I-24044 Dalmine (Italy); and others

    2016-07-11

    The INFN PixFEL project is developing the fundamental building blocks for a large area X-ray imaging camera to be deployed at next generation free electron laser (FEL) facilities with unprecedented intensity. Improvement in performance beyond the state of art in imaging instrumentation will be explored adopting advanced technologies like active edge sensors, a 65 nm node CMOS process and vertical integration. These are the key ingredients of the PixFEL project to realize a seamless large area focal plane instrument composed by a matrix of multilayer four-side buttable tiles. In order to minimize the dead area and reduce ambiguities in image reconstruction, a fine pitch active edge thick sensor is being optimized to cope with very high intensity photon flux, up to 10{sup 4} photons per pixel, in the range from 1 to 10 keV. A low noise analog front-end channel with this wide dynamic range and a novel dynamic compression feature, together with a low power 10 bit analog to digital conversion up to 5 MHz, has been realized in a 110 μm pitch with a 65 nm CMOS process. Vertical interconnection of two CMOS tiers will be also explored in the future to build a four-side buttable readout chip with high density memories. In the long run the objective of the PixFEL project is to build a flexible X-ray imaging camera for operation both in burst mode, like at the European X-FEL, or in continuous mode with the high frame rates anticipated for future FEL facilities.

  11. The PixFEL project: Progress towards a fine pitch X-ray imaging camera for next generation FEL facilities

    International Nuclear Information System (INIS)

    Rizzo, G.; Batignani, G.; Benkechkache, M.A.; Bettarini, S.; Casarosa, G.; Comotti, D.; Dalla Betta, G.-F.; Fabris, L.; Forti, F.; Grassi, M.; Lodola, L.; Malcovati, P.; Manghisoni, M.

    2016-01-01

    The INFN PixFEL project is developing the fundamental building blocks for a large area X-ray imaging camera to be deployed at next generation free electron laser (FEL) facilities with unprecedented intensity. Improvement in performance beyond the state of art in imaging instrumentation will be explored adopting advanced technologies like active edge sensors, a 65 nm node CMOS process and vertical integration. These are the key ingredients of the PixFEL project to realize a seamless large area focal plane instrument composed by a matrix of multilayer four-side buttable tiles. In order to minimize the dead area and reduce ambiguities in image reconstruction, a fine pitch active edge thick sensor is being optimized to cope with very high intensity photon flux, up to 10"4 photons per pixel, in the range from 1 to 10 keV. A low noise analog front-end channel with this wide dynamic range and a novel dynamic compression feature, together with a low power 10 bit analog to digital conversion up to 5 MHz, has been realized in a 110 μm pitch with a 65 nm CMOS process. Vertical interconnection of two CMOS tiers will be also explored in the future to build a four-side buttable readout chip with high density memories. In the long run the objective of the PixFEL project is to build a flexible X-ray imaging camera for operation both in burst mode, like at the European X-FEL, or in continuous mode with the high frame rates anticipated for future FEL facilities.

  12. Quantitative analysis of soluble elements in environmental waters by PIXE

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Adachi, M.; Tsuji, M.; Hattori, T.

    1999-01-01

    We have started PIXE research for environmental science at Van de Graaff accelerator facility in Tokyo Institute of Technology. Quantitative measurements of soluble fractions in river waters have been carried out using the preconcentrate method developed in Tohoku University. We reveal that this PIXE target preparation can be also applied to waste water samples. (author)

  13. Characterization of regional atmospheric aerosols over Hungary by PIXE elemental analysis

    International Nuclear Information System (INIS)

    Koltay, E.; Szabo, G.; Borbely Kiss, I.; Somorjai, E.; Kiss, A.Z.

    1994-01-01

    Studying the characteristic features of atmospheric aerosols emitted by natural and anthropogenic sources is of basic importance for a detailed understanding of the physics and chemistry of the atmosphere. Environmental pollution by atmospheric aerosols and their impact can be tested in the same way, too. The separation of natural and anthropogenic components of the aerosol can be done through enrichment factors and size distribution curves deduced from analytical information. The Particle Induced X-ray Emission (PIXE) technique has been applied in aerosol studies by the authors. Results obtained on atmospheric aerosols collected over Hungary and presented in terms of concentrations, enrichment factors, regional signatures, deposition velocities, transport properties and apportionment of sources illustrate the scope and proportions of the potential contribution of PIXE to the methodology of atmospheric aerosol studies. Continued activity planned in the framework of the present CRP may widen the scope of the investigations mainly in the field of size-fractioned sampling and - possibly - in the direction of individual characterization of aerosol particles. (author). 14 refs

  14. The PixFEL project: development of advanced X-ray pixel detectors for application at future FEL facilities

    International Nuclear Information System (INIS)

    Rizzo, G.; Batignani, G.; Bettarini, S.; Casarosa, G.; Forti, F.; Paladino, A.; Paoloni, E.; Comotti, D.; Grassi, M.; Lodola, L.; Malcovati, P.; Ratti, L.; Vacchi, C.; Fabris, L.; Manghisoni, M.; Re, V.; Traversi, G.; Morsani, F.; Betta, G.-F. Dalla; Pancheri, L.

    2015-01-01

    The PixFEL project aims to develop an advanced X-ray camera for imaging suited for the demanding requirements of next generation free electron laser (FEL) facilities. New technologies can be deployed to boost the performance of imaging detectors as well as future pixel devices for tracking. In the first phase of the PixFEL project, approved by the INFN, the focus will be on the development of the microelectronic building blocks, carried out with a 65 nm CMOS technology, implementing a low noise analog front-end channel with high dynamic range and compression features, a low power ADC and high density memory. At the same time PixFEL will investigate and implement some of the enabling technologies to assembly a seamless large area X-ray camera composed by a matrix of multilayer four-side buttable tiles. A pixel matrix with active edge will be developed to minimize the dead area of the sensor layer. Vertical interconnection of two CMOS tiers will be explored to build a four-side buttable readout chip with small pixel pitch and all the on-board required functionalities. The ambitious target requirements of the new pixel device are: single photon resolution, 1 to 10 4 photons @ 1 keV to 10 keV input dynamic range, 10-bit analog to digital conversion up to 5 MHz, 1 kevent in-pixel memory and 100 μm pixel pitch. The long term goal of PixFEL will be the development of a versatile X-ray camera to be operated either in burst mode (European XFEL), or in continuous mode to cope with the high frame rates foreseen for the upgrade phase of the LCLS-II at SLAC

  15. Diagnosis of spatial resolution for microbeam scanning PIXE using STIM method and CR-39 track detector in PASTA

    International Nuclear Information System (INIS)

    Hamano, T.; Imaseki, H.; Yukawa, M.; Ishikawa, T.; Iso, H.; Matsumoto, K.

    2003-01-01

    In PIXE analysis system and Tandem Accelerator facility (PASTA) of NIRS, we are using Scanning Transmission Ion Microscopy (STIM) method and solid track detector to diagnose the spatial resolution of scanning microbeam PIXE analysis system. These methods are widely used by many microbeam facilities. (author)

  16. MAPPIX: A software package for off-line micro-pixe single particle aerosol analysis

    International Nuclear Information System (INIS)

    Ceccato, D.

    2009-01-01

    In the framework of a multiannual experiment performed at Baia Terra Nova, Antarctica, size-segregated aerosol samples were collected by using a 12-stage SDI impactor (Hillamo design). Approximately 2800 particles, belonging to the first four supermicrometric SDI stages - 8.39, 4.08, 2.68, 1.66 μm dynamic aerosol diameter cuts - were analyzed at the INFN-LNL micro-PIXE facility, a three lens Oxford Microprobe (OM) product, installed in the early nineties. Four regions on each of the 12 sub-samples were measured; 60 aerosol particles were detected on average in each of the analyzed regions. The off-line single aerosol particle (SAP) analysis of such big amount of data required software that is able to rapidly handle the acquired data, with a simple and fast area selection procedure; the subsequent automated PIXE spectra analysis with a specialized code was also needed. The MAPPIX 2.0 software was designed to make easier and faster the user jobs during the SAP analysis. The package is composed of two separate routines: the first one is devoted to data format conversion (OM-LMF file format to MAPPIX format), while the second one is devoted to micro-PIXE maps graphical presentation and aerosol particle selection procedure. The MAPPIX data format and software features will be discussed; a short report of the speed performances will be presented.

  17. Fundamentals of PIXE analysis

    International Nuclear Information System (INIS)

    Ishii, Keizo

    1997-01-01

    Elemental analysis based on the particle induced x-ray emission (PIXE) is a novel technique to analyze trace elements. It is a very simple method, its sensitivity is very high, multiple elements in a sample can be simultaneously analyzed and a few 10 μg of a sample is enough to be analyzed. Owing to these characteristics, the PIXE analysis is now used in many fields (e.g. biology, medicine, dentistry, environmental pollution, archaeology, culture assets etc.). Fundamentals of the PIXE analysis are described here: the production of characteristic x-rays and inner shell ionization by heavy charged particles, the continuous background in PIXE spectrum, quantitative formulae of the PIXE analysis, the detection limit of PIXE analysis, etc. (author)

  18. Applications of PIXE in dendrochronology

    International Nuclear Information System (INIS)

    Revesz, P.; Mayer, J.W.; Vizkelethy, G.; Kuniholm, P.I.; Griggs, C.B.; Kuniholm, H.E.; Newton, M.W.; Tarter, S.L.

    1991-01-01

    The Bard Hall Ion Beam Facility has developed external proton beams at 1-3 MeV for ion-induced x-ray emission studies of artists' pigments and metallic printers inks. The authors have extended these PIXE measurements to analysis of Athenian Tetradrachms (5th and 6th centuries BC). In both pigment and coin studies they have compared PIXE analyses with those from XRF and electron micro probe for calibration purposes. The Aegean Dendrochronology Project has developed over 5500 years of tree-ring chronologies for the Aegean, Balkans, and Eastern Mediterranean. Included are forest sites adjacent to mining and smelting operations, also sites at the upper timberline where the annual growth-rings might be expected to have picked up fallout from volcanic activity around the world. A preliminary examination of selected rings by PIXE has shown remarkable differences from year to year in the deposition of various elements, notable Zn, Fe, and Cu. The authors propose to look at a number of selected annual ring sequences to see (1) whether one can chart the progress of known metallurgical activity; (2) whether one can find evidence for volcanic effects, both for absolutely-dated volcanoes such as Krakatoa, Tambora, and Sumbawa, and for problematic volcanoes such as Santorini/Thera

  19. PIXE analysis by baby cyclotron

    International Nuclear Information System (INIS)

    Yoshida, Hyogo; Tanaka, Teruaki; Ito, Takashi; Toda, Yohjiro; Wakasa, Hideichiro

    1988-01-01

    The Japan Steel Works, Ltd. has been supplying a very small sized cyclotron (Baby Cyclotron) to hospitals and research facilities. The cyclotron is designed to produce short-lived radioisotopes for medical use. In the present study, this cyclotron is modified so that it can serve for PIXE analysis. The PIXE (particle induced X-ray emission) technique has the following features: (1) Down to 1 ng of trace material in a sample (mg - μg) can be detected, (2) An analysis run is completed in one to ten minutes, permitting economical analysis for a large number of samples, (3) Several elements can be analyzed simultaneously, with an almost constant sensitivity for a variety of elements ranging from aluminum to heavy metals, (4) Analysis can be performed nondestructively without a chemical process, and (5) The use of microbeam can provide data on the distribution of elements with a resolution of several μm. Software for analysis is developed to allow the modified equipment to perform peak search, background fitting, and identification and determination of peaks. A study is now being conducted to examine the performance of the equipment for PIXE analysis of thin samples. Satisfactory results have been obtained. The analysis time, excluding the background correction, is 5-10 min. (Nogami, K.)

  20. Pixe method as microanalytical instrument

    International Nuclear Information System (INIS)

    Tabacniks, M.H.

    1986-02-01

    The PIXE method (Particle Induced X-Ray Emission) as analytical method presenting the evolution, the theoretical fundaments, the detection limit, the optimization for operational conditions is evaluated. The applications of the method to air pollution control and aerosol studies in regions such as Antartic, Amazon and other regions are analysed. (M.C.K.) [pt

  1. PIXE and ICP-MS analysis of fenugreek medicinal plant from different regions

    International Nuclear Information System (INIS)

    Chandrasekhar Rao, J.; Naidu, B.G.; Sarita, P.; Naga Raju, G.J.

    2017-01-01

    Elemental analysis of Fenugreek medicinal plant collected from different regions was carried out by Proton Induced X-ray Emission (PIXE) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) techniques. The elements Li, Be, Al, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Ag, Cd, Ba, Pb and U were identified and their concentrations were estimated. These elements were found to be in widely varying concentrations in the analyzed Fenugreek medicinal plant collected from different regions. of the. The results of the present study provide a better understanding of the pharmacological action of Fenugreek medicinal plant and it can also be used to set new standards for prescribing the dosage of herbal drugs. (author)

  2. External-RBS, PIXE and NRA analysis for ancient swords

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Hellen C., E-mail: hellencsa@gmail.com; Added, Nemitala; Silva, Tiago F.; Rodrigues, C.L.

    2015-02-15

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi – São Paulo/Brazil, the latter being successfully implemented for the first time in this facility.

  3. External-RBS, PIXE and NRA analysis for ancient swords

    Science.gov (United States)

    Santos, Hellen C.; Added, Nemitala; Silva, Tiago F.; Rodrigues, C. L.

    2015-02-01

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi - São Paulo/Brazil, the latter being successfully implemented for the first time in this facility.

  4. External-RBS, PIXE and NRA analysis for ancient swords

    International Nuclear Information System (INIS)

    Santos, Hellen C.; Added, Nemitala; Silva, Tiago F.; Rodrigues, C.L.

    2015-01-01

    Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi – São Paulo/Brazil, the latter being successfully implemented for the first time in this facility

  5. PIXE: early NAA revisited

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    A short, comparative evaluation of the methods of neutron activation analysis (NAA), and particle induced X-ray emission (PIXE), is given based on the Proc. of the 2nd international conference on PIXE and its analytical applications. The conference took place June 9-12, 1980, Lund, Sweden. 'The PIXE people have paralleled NAA people - in work, problems and mistakes, summarises the author, but PIXE was proved and established as a standard analytical method.' The method has proved extremely valuable in microprobe applications. (Sz.J.)

  6. A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Beasley, D.G., E-mail: dgbeasley@ctn.ist.utl.pt [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Alves, L.C. [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Barberet, Ph.; Bourret, S.; Devès, G.; Gordillo, N.; Michelet, C. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Le Trequesser, Q. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Institut de Chimie de la Matière Condensée de Bordeaux (ICMCB, UPR9048) CNRS, Université de Bordeaux, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Marques, A.C. [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Seznec, H. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Silva, R.C. da [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal)

    2014-07-15

    The tomographic reconstruction of biological specimens requires robust algorithms, able to deal with low density contrast and low element concentrations. At the IST/ITN microprobe facility new GPU-accelerated reconstruction software, JPIXET, has been developed, which can significantly increase the speed of quantitative reconstruction of Proton Induced X-ray Emission Tomography (PIXE-T) data. It has a user-friendly graphical user interface for pre-processing, data analysis and reconstruction of PIXE-T and Scanning Transmission Ion Microscopy Tomography (STIM-T). The reconstruction of PIXE-T data is performed using either an algorithm based on a GPU-accelerated version of the Maximum Likelihood Expectation Maximisation (MLEM) method or a GPU-accelerated version of the Discrete Image Space Reconstruction Algorithm (DISRA) (Sakellariou (2001) [2]). The original DISRA, its accelerated version, and the MLEM algorithm, were compared for the reconstruction of a biological sample of Caenorhabditis elegans – a small worm. This sample was analysed at the microbeam line of the AIFIRA facility of CENBG, Bordeaux. A qualitative PIXE-T reconstruction was obtained using the CENBG software package TomoRebuild (Habchi et al. (2013) [6]). The effects of pre-processing and experimental conditions on the elemental concentrations are discussed.

  7. Application of PIXE to the characterization of vitreous dacites from archaeolgical sites in the Atacama region in northern Chile

    Energy Technology Data Exchange (ETDEWEB)

    Morales, J.R.; Cancino, S. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago 1 (Chile); Miranda, P. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago 1 (Chile)], E-mail: pjmirand@gmail.com; Dinator, M.I. [Departamento de Fisica, Facultad de Ciencias, Universidad de Chile, Las Palmeras 3425, Nunoa, Santiago 1 (Chile); Seelenfreund, A. [Universidad Academia de Humanismo Cristiano, Condell 343, Providencia, Santiago (Chile)

    2007-11-15

    Geochemical characterization studies using PIXE were carried out on 21 vitreous dacite artifacts from early formative archaeological sites in the Atacama region, in northern Chile, and on 13 samples taken from two potential volcanic sources located within the region. Performing statistical analyses it was possible to obtain elemental concentration patterns for the archaeological samples of this material and match some of these artifacts with the geological source samples.

  8. In-vivo elemental imaging of plants using in-air submilli-PIXE camera

    International Nuclear Information System (INIS)

    Matsuyama, Shigeo; Ishii, Keizo; Kikuchi, Yohei; Kawamura, Yu; Yamazaki, Hiromichi; Watanabe, Ryohei; Tashiro, Kumiko; Inoue, Chihiro

    2008-01-01

    We developed a PIXE analysis system which provides spatial distribution images of elements in a region of 3x3 cm 2 with a spatial resolution of ∼0.5 mm. We call this system a submilli-PIXE camera. For in-vivo imaging of plants, we combined the submilli-PIXE camera with an in-air analysis. The high-speed beam scanning and the in-air analysis also reduce the risk of damaging the plants, thus in-vivo imaging could be realized. We applied the in-air submilli-PIXE camera to phytoremediation research. Phytoremediation is a technology for cleaning metal-contaminated soils using plant physiology. To study accumulation mechanisms for heavy metals, elemental distribution in plant organ should be known as well as average concentration. Elemental images of fronds were obtained in-vivo without sample preparation. Elemental map of the fronds showed that arsenic was accumulated in the edges of Pteris vittata fronds. The in-air submilli-PIXE camera clearly shows the accumulation of arsenic in fronds. The in-air submilli-PIXE camera is an effective tool for undertaking phytoremediation research. (author)

  9. Enhanced identification of trace element fingerprint of prehistoric pigments by PIXE mapping

    Science.gov (United States)

    Lebon, M.; Pichon, L.; Beck, L.

    2018-02-01

    The elemental composition of Fe rich rocks used as pigment during prehistoric periods can provide valuable information about the type of material used and their geological origin. However, these materials present several analytical constraints since their patrimonial value involve using non-invasive techniques maintaining a high sensitivity of the detection and the quantification of trace elements. Micro-beam techniques also require to take into account the heterogeneity of these geomaterials from the macroscopic to microscopic scales. Several previous studies have demonstrated that PIXE analysis satisfies these analytical conditions. However, application of micro-PIXE analysis is still complex when thin and discontinuous layer of pigment is deposed on the surface of other materials such as rocks or bones. In such case, PIXE imaging could improve the ability to take into account the high heterogeneity of such archaeological objects. In study, we used PIXE imaging system developed at the NewAGLAE facility in order to visualize distribution of elements associated with iron-rich pigment phase. The results obtained show that PIXE maps can improve the identification of the main trace elements specific to the iron mineral phase. By grouping pixels of iron-rich areas and performing quantitative treatment, it was possible to reveal additional trace elements associated to pigment. This study highlights the contribution of PIXE imaging to the identification of elements associated with mineral phases of interest and to use them as proxies to discriminate different geological materials used in archaeological context.

  10. Internal/external mixing of aerosol particles elemental composition retrieved from microPIXE and PIXE

    International Nuclear Information System (INIS)

    Ghermandi, G.; Cecchi, R.; Lusvarghi, L.; Laj, P.; Zappoli, S.; Ceccato, D.

    2005-01-01

    A statistical evaluation of the association between different elements contained in atmospheric aerosol particles has been made using the microPIXE technique. We derived elemental maps of Al, Si, S, Ca, Cl, K, Fe, Mg spatial distribution on the surface of a Nuclepore filter sample. The microPIXE measurements are validated by comparison to conventional PIXE and SEM-EDAX. Then, the spatial coherence of the different elements is analysed using statistical methods. The elements are not homogeneously distributed and the association among specific elements can be identified. MicroPIXE and factorial analysis can be coupled to understand the state of mixing of the different elements on the filter surface

  11. PIXE analysis of historical paintings: Is the gain worth the risk?

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS – Ministère de la Culture – IRCP, Palais du Louvre, 75001 Paris (France); Gonzalez, V. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche Chimie Paris, UMR8247, 75005 Paris (France); Pichon, L. [Centre de recherche et de restauration des musées de France, C2RMF, Palais du Louvre – Porte des Lions, 14 Quai François Mitterrand, 75001 Paris (France); Fédération de recherche NewAGLAE, FR3506 CNRS – Ministère de la Culture – IRCP, Palais du Louvre, 75001 Paris (France)

    2015-11-15

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm{sup 2} or μC/cm{sup 2}. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1–300 μC/cm{sup 2}) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using

  12. PIXE analysis of historical paintings: Is the gain worth the risk?

    International Nuclear Information System (INIS)

    Calligaro, T.; Gonzalez, V.; Pichon, L.

    2015-01-01

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm"2 or μC/cm"2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1–300 μC/cm"2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory

  13. PIXE analysis of historical paintings: Is the gain worth the risk?

    Science.gov (United States)

    Calligaro, T.; Gonzalez, V.; Pichon, L.

    2015-11-01

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm2 or μC/cm2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1-300 μC/cm2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory-based scanning

  14. PIXE analysis of thin samples

    International Nuclear Information System (INIS)

    Kiss, Ildiko; Koltay, Ede; Szabo, Gyula; Laszlo, S.; Meszaros, A.

    1985-01-01

    Particle-induced X-ray emission (PIXE) multielemental analysis of thin film samples are reported. Calibration methods of K and L X-lines are discussed. Application of PIXE analysis to aerosol monitoring, multielement aerosol analysis is described. Results of PIXE analysis of samples from two locations in Hungary are compared with the results of aerosol samples from Scandinavia and the USA. (D.Gy.)

  15. Analysis of obsidians by PIXE technique

    International Nuclear Information System (INIS)

    Nuncio Q, A.E.

    1998-01-01

    This work presents the characterization of obsydian samples from different mineral sites in Mexico, undertaken by an Ion Beam Analysis: PIXE (Proton Induced X-ray Emission). As part of an intensive investigation of obsidian in Mesoamerica by anthropologists from Mexico National Institute of Anthropology and History, 818 samples were collected from different volcanic sources in central Mexico for the purpose of establishing a data bank of element concentrations of each source. Part of this collection was analyzed by Neutron activation analysis and most of the important elements concentrations reported. In this work, a non-destructive IBA technique (PIXE) are used to analyze obsydian samples. The application of this technique were carried out at laboratories of the ININ Nuclear Center facilities. The samples consisted of of obsydians from ten different volcanic sources. This pieces were mounted on a sample holder designed for the purpose of exposing each sample to the proton beam. This PIXE analysis was carried out with an ET Tandem Accelerator at the ININ. X-ray spectrometry was carried out with an external beam facility employing a Si(Li) detector set at 52.5 degrees in relation to the target normal (parallel to the beam direction) and 4.2 cm away from the target center. A filter was set in front of the detector, to determine the best attenuation conditions to obtain most of the elements, taking into account that X-ray spectra from obsydians are dominated by intense major elements lines. Thus, a 28 μ m- thick aluminium foil absorber was selected and used to reduce the intensity of the major lines as well as pile-up effects. The mean proton energy was 2.62 MeV, and the beam profile was about 4 mm in diameter. As results were founded elemental concentrations of a set of samples from ten different sources: Altotonga (Veracruz), Penjamo (Guanajuato), Otumba (Mexico), Zinapecuaro (Michoacan), Ucareo (Michoacan), Tres Cabezas (Puebla), Sierra Navajas (Hidalgo), Zaragoza

  16. Application of micro-PIXE technique to uptake study of cesium by Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Ohnuki, Toshihiko; Sakamoto, Fuminori; Kozai, Naofumi; Ozaki, Takuo; Narumi, Issei; Francis, Arokiasamy J.; Iefuji, Haruyuki; Sakai, Takuro; Kamiya, Tomihiro; Satoh, Takahiro; Oikawa, Masakazu

    2003-01-01

    We examined the accumulation and distribution of Cs, and the presence of other elements in yeast (Saccharomyces cerevisiae) cells by the micro-PIXE (particle induced X-ray emission) system developed at the TIARA facility, JAERI, and by energy dispersive spectroscopy (EDS) coupled to a scanning electron microscope. The effects of Cs on yeast growth were determined by measuring the optical density at 600 nm. Addition of 1 mM Cs did not have any effect on the growth of the yeast. Micro-PIXE analysis of cells grown in the presence of Cs showed that Cs was uniformly distributed in the cells. Using PIXE, Cs, P, K and Fe can be detected, whereas only P and S can be determined by the EDS. Cells exposed to Cs showed an increase in Cs peak intensity, and decrease in P, K and Fe with time. These results suggest that micro-PIXE is a useful technique to detect low concentration of toxic elements in microorganisms as well as to monitor their changes as function of growth

  17. Characterization of regional atmospheric aerosols over Hungary by PIXE elemental analysis. Appendix 9

    International Nuclear Information System (INIS)

    Koltay, E.; Borbely-Kiss, I.; Szabo, Gy.; Kiss, A.Z.; Rajta, I.; Somorjai, E.; Meszaros, E.; Molnar, A.; Bozo, L.

    1995-01-01

    Earlier PIXE analytical data obtained on rural aerosol samples from Hungary have been extended by the results of further analyses in the frame of the present international Co-ordinated Research Programme. Samples have been collected in three more rural, one suburban and two urban stations. A comparison of the data revealed the distribution of aerosol loading by several trace elements over the country, supported the determination of aerosol budget indicating long-range transport from industrial sources and Saharan dust intrusion. The data show that Hungarian air is moderately polluted by aerosols from regional and faraway sources. Methodological results have been obtained in setting up a new microbeam channel for individual characterization of aerosol particles. (author)

  18. Role of βPix in the kidney

    Directory of Open Access Journals (Sweden)

    Alexander eStaruschenko

    2012-05-01

    Full Text Available Small GTPases function as molecular switches in cell signaling, alternating between an inactive, GDP-bound state, and active GTP-bound state. βPix is one of guanine nucleotide exchange factors (GEFs that catalyze the exchange of bound GDP for ambient GTP. The central goal of this review article is to summarize recent findings on βPix and the role it plays in kidney pathology and physiology. Recent studies shed new light on several key questions concerning the signaling mechanisms mediated by βPix. This manuscript provides a review of the various mechanisms whereby βPix has been shown to function within the kidney through a wide range of actions. Both canonical GEF activity and non-canonical signaling pathways mediated by βPix are discussed. Distribution patterns of βPix in the kidney will be also covered. Much has yet to be discerned, but it is clear that βPix plays a significant role in the kidney.

  19. Uncertainties in thick-target PIXE analysis

    International Nuclear Information System (INIS)

    Campbell, J.L.; Cookson, J.A.; Paul, H.

    1983-01-01

    Thick-target PIXE analysis insolves uncertainties arising from the calculation of thick-target X-ray production in addition to the usual PIXE uncertainties. The calculation demands knowledge of ionization cross-sections, stopping powers and photon attenuation coefficients. Information on these is reviewed critically and a computational method is used to estimate the uncertainties transmitted from this data base into results of thick-target PIXE analyses with reference to particular specimen types using beams of 2-3 MeV protons. A detailed assessment of the accuracy of thick-target PIXE is presented. (orig.)

  20. A new mapping acquisition and processing system for simultaneous PIXE-RBS analysis with external beam

    International Nuclear Information System (INIS)

    Pichon, L.; Beck, L.; Walter, Ph.; Moignard, B.; Guillou, T.

    2010-01-01

    The combination of ion beam analysis techniques is particularly fruitful for the study of cultural heritage objects. For several years, the AGLAE facility of the Louvre laboratory has been implementing these techniques with an external beam. The recent set-up permits to carry out PIXE, PIGE and RBS simultaneously on the same analyzed spot with a particle beam of approximately 20 μm diameter. A new mapping system has been developed in order to provide elemental concentration maps from the PIXE and RBS spectra. This system combines the Genie2000 spectroscopy software with a homemade software that creates maps by handling acquisition with the object position. Each pixel of each PIXE and RBS maps contains the spectrum normalised by the dose. After analysing each pixel of the PIXE maps (low and high energy X-ray spectra) with the Gupixwin peak-fitting software, quantitative elemental concentrations are obtained for the major and trace elements. This paper presents the quantitative elemental maps extracted from the PIXE spectra and the development of RBS data processing for light element distribution and thin layer characterization. Examples on rock painting and lustrous ceramics will be presented.

  1. PIXE in cultural heritage studies: present role and new challenges

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T.; Dran, J.-C. [Centre de Recherche et de Restauration des Musées de France, Palais du Louvre, Paris (France)

    2013-07-01

    Full text: The non-destructive study of artistic and archaeological objects relies on the use of a large panel of modern analytical tools. Among them, PIXE plays a prominent role due to its almost unique combination of excellent analytical features in terms of sensitivity and accuracy combined with a non-destructive and even non-invasive character. the latter advantage stems from extensive instrumental progress - like the external beam - carried out since the advent of PIXE in the 1970s to account for the precious and unique nature of artworks and archaeological artifacts that preclude any sampling or damage. the situation has however evolved in the recent years as several competing techniques providing non-destructively the chemical composition have arisen, which more or less shake the privileged status of PIXE. On one hand, analytical techniques implemented with tabletop or movable XRF instruments have been massively developed, which allow in situ analysis and represent a progress in terms of artworks safety and flexibility of analysis. On the other hand, access to synchrotron radiation facilities is becoming easier and therefore the use of the powerful X-ray absorption techniques (XANES, EXAFS), that add chemical environment information to the elemental analysis, is progressively gaining popularity. Considering these trends, it seems important to reassess the place of PIXE in the field of art and archaeology and to underline its specific assets. the aim of this article is to pinpoint the situation where PIXE is the best analytical tool with regard to the specificity of art and archaeological items and to stress the new challenges it will have to face. Case studies carried out with the AGLAE facility of the C2RMF will illustrate the situations where PIXE exhibits specific advantages: Light element measurement. The high ionization cross section of light elements by charged particles favors the accurate measurement of sodium, magnesium, aluminum and silicon, whose

  2. PIXE in cultural heritage studies: present role and new challenges

    International Nuclear Information System (INIS)

    Calligaro, T.; Dran, J.-C.

    2013-01-01

    Full text: The non-destructive study of artistic and archaeological objects relies on the use of a large panel of modern analytical tools. Among them, PIXE plays a prominent role due to its almost unique combination of excellent analytical features in terms of sensitivity and accuracy combined with a non-destructive and even non-invasive character. the latter advantage stems from extensive instrumental progress - like the external beam - carried out since the advent of PIXE in the 1970s to account for the precious and unique nature of artworks and archaeological artifacts that preclude any sampling or damage. the situation has however evolved in the recent years as several competing techniques providing non-destructively the chemical composition have arisen, which more or less shake the privileged status of PIXE. On one hand, analytical techniques implemented with tabletop or movable XRF instruments have been massively developed, which allow in situ analysis and represent a progress in terms of artworks safety and flexibility of analysis. On the other hand, access to synchrotron radiation facilities is becoming easier and therefore the use of the powerful X-ray absorption techniques (XANES, EXAFS), that add chemical environment information to the elemental analysis, is progressively gaining popularity. Considering these trends, it seems important to reassess the place of PIXE in the field of art and archaeology and to underline its specific assets. the aim of this article is to pinpoint the situation where PIXE is the best analytical tool with regard to the specificity of art and archaeological items and to stress the new challenges it will have to face. Case studies carried out with the AGLAE facility of the C2RMF will illustrate the situations where PIXE exhibits specific advantages: Light element measurement. The high ionization cross section of light elements by charged particles favors the accurate measurement of sodium, magnesium, aluminum and silicon, whose

  3. Characterisation of candidate reference materials by PIXE analysis and nuclear microprobe PIXE imaging

    International Nuclear Information System (INIS)

    Jaksic, M.; Pastuovic, Z.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    In order to test whether some candidate reference materials show homogeneity that can satisfy quality control of the PIXE technique, six bottles of each of the two Candidate RM's - Lichen (IAEA 338) and Algae (IAEA 413) were tested. Four different tests were performed. First, two pellets from each bottle were prepared and analysed using broad beam (φ = 5 mm) PIXE. Second and third was analysis of homogeneity using scanning focussed beam at the nuclear microprobe. Scans of 50x50 μm 2 and 240x260 μm 2 were performed. Finally, individual grains with composition differing from the rest of the sample, were analysed using PIXE and RBS. (author)

  4. Micro-PIXE for single cell analysis

    International Nuclear Information System (INIS)

    Ortega, Richard

    2012-01-01

    The knowledge of the intracellular distribution of biological relevant metals is important to understand their mechanisms of action in cells, either for physiological, toxicological or pathological processes. However, the direct detection of trace metals in single cells is a challenging task that requires sophisticated analytical developments. The combination of micro-PIXE with RBS and STIM (Scanning Transmission Ion Microscopy) allows the quantitative determination of trace metal content within sub-cellular compartments. The application of STIM analysis provides high spatial resolution imaging (< 200 nm) and excellent mass sensitivity (< 0.1 ng). Application of the STIM-PIXE-RBS methodology is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. This combination of STIM-PIXE-RBS provides fully quantitative determination of trace element content, expressed in μg/g, which is a quite unique capability for micro-PIXE compared to other micro-analytical methods such as the electron and synchrotron x-ray fluorescence. Examples of micro-PIXE studies for sub-cellular imaging of trace elements in various fields of interest will be presented: in patho-physiology of trace elements involved in neurodegenerative diseases such as Parkinson's disease, and in toxicology of metals such as cobalt. (author)

  5. Pix proteins and the evolution of centrioles.

    Science.gov (United States)

    Woodland, Hugh R; Fry, Andrew M

    2008-01-01

    We have made a wide phylogenetic survey of Pix proteins, which are constituents of vertebrate centrioles in most eukaryotes. We have also surveyed the presence and structure of flagella or cilia and centrioles in these organisms, as far as is possible from published information. We find that Pix proteins are present in a vast range of eukaryotes, but not all. Where centrioles are absent so are Pix proteins. If one considers the maintenance of Pix proteins over evolutionary time scales, our analysis would suggest that their key function is to make cilia and flagella, and the same is true of centrioles. Moreover, this survey raises the possibility that Pix proteins are only maintained to make cilia and flagella that undulate, and even then only when they are constructed by transporting ciliary constituents up the cilium using the intraflagellar transport (IFT) system. We also find that Pix proteins have become generally divergent within Ecdysozoa and between this group and other taxa. This correlates with a simplification of centrioles within Ecdysozoa and a loss or divergence of cilia/flagella. Thus Pix proteins act as a weathervane to indicate changes in centriole function, whose core activity is to make cilia and flagella.

  6. Micro-ERDA, micro-RBS and micro-PIXE techniques in the investigation of fish otoliths

    International Nuclear Information System (INIS)

    Huszank, R.; Simon, A.; Szilagyi, E.; Keresztessy, K.; Kovacs, I.

    2009-01-01

    Elemental distribution in the otolith of the fresh water fish burbot (Lota lota L.) collected in Hungary was measured with Elastic Recoil Detection Analysis (ERDA), Rutherford Backscattering Spectrometry (RBS) and as a complementary technique, Particle-Induced X-ray Emission (PIXE) with a focussed ion beam of 1.5 x 1.5 μm 2 spot size. The organic- and inorganic-rich regions of the otolith are distinguished and they are presented as hydrogen and calcium maps at depth regions of 0-70, 70-140 and 140-210 nm. The textured surface of the sample and its porosity were characterized from the effect on the RBS spectra. The oxygen and carbon PIXE elemental maps can also be used to identify the organic- and inorganic-rich regions of the otolith. The calcium map was found to be more homogeneous because the otolith structure is averaged in a larger depth. The trace elements Fe, Zn and Sr were detected only in very low concentration by micro-PIXE.

  7. Micro-ERDA, micro-RBS and micro-PIXE techniques in the investigation of fish otoliths

    Energy Technology Data Exchange (ETDEWEB)

    Huszank, R. [Institute of Nuclear Research of the Hungarian Academy of Sciences, P.O. Box 51, H-4001 Debrecen (Hungary)], E-mail: huszank@atomki.hu; Simon, A. [Institute of Nuclear Research of the Hungarian Academy of Sciences, P.O. Box 51, H-4001 Debrecen (Hungary); Szilagyi, E. [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary); Keresztessy, K. [Department of Fish Culture, Institute of Environmental and Landscape Management, Szent Istvan University, Pater K.u.1, H-2103 Goedoello (Hungary); Kovacs, I. [KFKI Research Institute for Particle and Nuclear Physics, P.O. Box 49, H-1525 Budapest (Hungary)

    2009-06-15

    Elemental distribution in the otolith of the fresh water fish burbot (Lota lota L.) collected in Hungary was measured with Elastic Recoil Detection Analysis (ERDA), Rutherford Backscattering Spectrometry (RBS) and as a complementary technique, Particle-Induced X-ray Emission (PIXE) with a focussed ion beam of 1.5 x 1.5 {mu}m{sup 2} spot size. The organic- and inorganic-rich regions of the otolith are distinguished and they are presented as hydrogen and calcium maps at depth regions of 0-70, 70-140 and 140-210 nm. The textured surface of the sample and its porosity were characterized from the effect on the RBS spectra. The oxygen and carbon PIXE elemental maps can also be used to identify the organic- and inorganic-rich regions of the otolith. The calcium map was found to be more homogeneous because the otolith structure is averaged in a larger depth. The trace elements Fe, Zn and Sr were detected only in very low concentration by micro-PIXE.

  8. Elemental analysis of artefacts - establishing external beam PIXE

    International Nuclear Information System (INIS)

    Alves, A.; Johnston, P.; Short, R.; Bubb, I.

    1999-01-01

    The development of an external PIXE facility on the 1 MV Tandetron accelerator at RMIT has led to a wide range of research possibilities. A proton beam, generated inside a vacuum is brought into air via an Au coated Kapton foil exit window (thickness 8μm, diameter 0.35mm). Monitoring of the beam intensity is achieved by detecting backscattered protons from the inside Au coating on the window. Artefacts, which may be too large to be placed inside the vacuum, are positioned in the beamline opposite the exit window. An optical system consisting of a CCD camera, alignment laser and two mirrors allows viewing of a region of the target 10mm x 10mm. This technique provides quantitative analysis of elements in the pigments used in paintings and on ceramics, which is a valuable tool in art conservation and authentication. Application of the technique to a ceramic sample from the historic house 'Viewbank' is described

  9. Pix proteins and the evolution of centrioles.

    Directory of Open Access Journals (Sweden)

    Hugh R Woodland

    Full Text Available We have made a wide phylogenetic survey of Pix proteins, which are constituents of vertebrate centrioles in most eukaryotes. We have also surveyed the presence and structure of flagella or cilia and centrioles in these organisms, as far as is possible from published information. We find that Pix proteins are present in a vast range of eukaryotes, but not all. Where centrioles are absent so are Pix proteins. If one considers the maintenance of Pix proteins over evolutionary time scales, our analysis would suggest that their key function is to make cilia and flagella, and the same is true of centrioles. Moreover, this survey raises the possibility that Pix proteins are only maintained to make cilia and flagella that undulate, and even then only when they are constructed by transporting ciliary constituents up the cilium using the intraflagellar transport (IFT system. We also find that Pix proteins have become generally divergent within Ecdysozoa and between this group and other taxa. This correlates with a simplification of centrioles within Ecdysozoa and a loss or divergence of cilia/flagella. Thus Pix proteins act as a weathervane to indicate changes in centriole function, whose core activity is to make cilia and flagella.

  10. PIXE as an analytical/educational tool

    International Nuclear Information System (INIS)

    Williams, E.T.

    1991-01-01

    The advantages and disadvantages of PIXE as an analytical method will be summarized. The authors will also discuss the advantages of PIXE as a means of providing interesting and feasible research projects for undergraduate science students

  11. Analysis of iron gall inks by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Budnar, Milos [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia)]. E-mail: milos.budnar@ijs.si; Ursic, Mitja [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Simcic, Jure [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Pelicon, Primoz [Jozef Stefan Institute, Jamova 39, p.p. 3000, SI-1001 Ljubljana (Slovenia); Kolar, Jana [National University Library, Turjaska 1, SI-1000 Ljubljana (Slovenia); Selih, Vid Simon [University of Ljubljana, Faculty of Chemistry and Chemical Technology, Askerceva 5, SI-1000 Ljubljana (Slovenia); Strlic, Matija [University of Ljubljana, Faculty of Chemistry and Chemical Technology, Askerceva 5, SI-1000 Ljubljana (Slovenia)

    2006-02-15

    Micro- or non-destructive analytical approach is an imperative when analysing historical artefacts. Due to its practically non-destructive character, proton induced X-ray spectrometry (PIXE) has become a method of choice for the study of historical documents. In the present paper, use of in-air PIXE method for analysis of iron gall inks applied at handwriting of documents is evaluated. The errors arising from the non-uniform ink deposit, proton penetration depth and size of the proton beam versus width of ink lines, effects of surface roughness, as well as the importance of the PIXE set-up geometry on the accuracy of the results are discussed. It follows that the main problems can be attributed to the fact that PIXE is a surface technique and that the analysis is limited to a small amount of material, while ink deposit on the paper is usually non-uniform in depth as well as on the paper surface. Despite possible systematic uncertainties when applying the PIXE method, good correlation between determinations obtained by PIXE and atomic absorption spectroscopy (AAS) on model samples clearly demonstrate that the errors are well within a reasonable limit of a few percents.

  12. Analysis of iron gall inks by PIXE

    International Nuclear Information System (INIS)

    Budnar, Milos; Ursic, Mitja; Simcic, Jure; Pelicon, Primoz; Kolar, Jana; Selih, Vid Simon; Strlic, Matija

    2006-01-01

    Micro- or non-destructive analytical approach is an imperative when analysing historical artefacts. Due to its practically non-destructive character, proton induced X-ray spectrometry (PIXE) has become a method of choice for the study of historical documents. In the present paper, use of in-air PIXE method for analysis of iron gall inks applied at handwriting of documents is evaluated. The errors arising from the non-uniform ink deposit, proton penetration depth and size of the proton beam versus width of ink lines, effects of surface roughness, as well as the importance of the PIXE set-up geometry on the accuracy of the results are discussed. It follows that the main problems can be attributed to the fact that PIXE is a surface technique and that the analysis is limited to a small amount of material, while ink deposit on the paper is usually non-uniform in depth as well as on the paper surface. Despite possible systematic uncertainties when applying the PIXE method, good correlation between determinations obtained by PIXE and atomic absorption spectroscopy (AAS) on model samples clearly demonstrate that the errors are well within a reasonable limit of a few percents

  13. An open experiment of a submilli-PIXE camera

    International Nuclear Information System (INIS)

    Matsuyama, S.; Ishii, K.; Yamazaki, H.; Iwasaki, S.; Tokai, Y.; Sugimoto, A.; Endo, H.; Ozawa, T.

    1999-01-01

    We have annually held an open experiment of PIXE analysis since 1996 to get people's understanding on nuclear technology and radiation science. Up to the present, more than 270 participants joined and enjoyed the open experiments. This year, we demonstrated performance of a submilli-PIXE camera and had sixty-nine participants in the open experiment of PIXE. Elemental spatial distribution images gave deep impression to the participants. Half of the participants were high school students since the open experiment of PIXE was held during the period of open campus of Tohoku University. About ten percents of the participants were junior high school students. Our open experiment of PIXE was very effective to arouse public interest in radiation science and nuclear technology. (author)

  14. Characterization of human kidney stones using micro-PIXE and RBS: A comparative study between two different populations

    International Nuclear Information System (INIS)

    Pineda-Vargas, C.A.; Eisa, M.E.M.; Rodgers, A.L.

    2009-01-01

    The micro-PIXE and RBS techniques are used to investigate the matrix as well as the trace elemental composition of calcium-rich human tissues on a microscopic scale. This paper deals with the spatial distribution of trace metals in hard human tissues such as kidney stone concretions, undertaken at the nuclear microprobe (NMP) facility. Relevant information about ion beam techniques used for material characterization will be discussed. Mapping correlation between different trace metals to extract information related to micro-regions composition will be illustrated with an application using proton energies of 1.5 and 3.0 MeV and applied to a comparative study for human kidney stone concretions nucleation region analysis from two different population groups (Sudan and South Africa)

  15. External PIXE analysis of old inks and papers

    International Nuclear Information System (INIS)

    Hassanzadeh, A.; Lamehi-Rachti, M.; Oliaiy, P.; Rahighi, J.; Shokouhi, F.

    1999-01-01

    Proton Induced X-ray Emission, PIXE is a very well established analytical method. This technique of analysis can equally be applied both in vacuum, internal PIXE, and in atmosphere, external PIXE. External PIXE has been applied to material analysis in Van de Graaff laboratory at AEOI using filters and funny filters. Advantages of using these filters have been studied when analysing ancient written documents such as envelopes, inks, and newspapers. This technique clearly demonstrated the differences between new and old inks and papers. More data is needed to show other features of this technique. (author)

  16. Hair analysis using PIXE

    International Nuclear Information System (INIS)

    Li Hongkou.

    1983-10-01

    A simple new technique for examining single hair strands to obtain linear mass densities, longitudinal profiles and transverse distribution of each trace element is described. It is primarily based upon the PIXE technique, in combination with proton back- scattering. The three main components of this technique are: 1) An accurate way of using an interpolation method to evaluate the magnitude of the correction factor accounting for the proton energy loss and X-ray absorption in the bulk of the hair is formulated; 2) A simple method to qualitatively determine the transverse distribution of each trace element in a hair is in- troduced and proved to be effective; 3) Proton back-scattering is proved to be capable of providing an ideal linear measure of the geometric hair diameter, one of the most important parameters in quantifying the results of PIXE measurements in mass concentrations. Using the technique, a PIXE system designed and constructed for routine longitudinal scanning of single hair strands is also described. (Author)

  17. Elemental analysis of hair using PIXE-tomography and INAA

    International Nuclear Information System (INIS)

    Beasley, D.; Gomez-Morilla, I.; Spyrou, N.

    2008-01-01

    3D quantitative elemental maps of a section of a strand of hair were produced using a combination of PIXE-Tomography and simultaneous On/Off Axis STIM-Tomography at the University of Surrey Ion Beam Centre. The distributions of S, K, Cl, Ca, Fe and Zn were determined using the PIXE-T reconstruction package DISRA. The results were compared with conventional bulk PIXE analysis of tomographic data as determined using Dan32. The overall concentrations determined by PIXE were compared with elemental concentrations held in the University of Surrey Hair Database. All the entries currently in the database were produced using INAA. The merits and possible contributions of tomographic PIXE analysis to analysis of hair are discussed. The conclusions drawn from the PIXE-Tomography analysis can be used to argue for more stringent procedures for hair analysis at the University of Surrey. (author)

  18. Pittsburgh rainwater analysis by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K C; Cohen, B L; Frohliger, J O; Shabason, L

    1976-01-01

    Concentrations of thirteen elements in rainwater from the Pittsburgh, Pa., area were analysed by Charged Particle Induced X-ray Emission (PIXE). They were compared to rainwater in a rural area and air particulates in Pittsburgh. Local and non-local contributions are discussed. Washout ratios were calculated and found to be larger for smaller size particles, contrary to general belief. The work demonstrates the convenience of using PIXE.

  19. Application of PIXE analysis to atmospheric environmental studies

    International Nuclear Information System (INIS)

    Kasahara, Mikio

    1997-01-01

    Physical and chemical properties of the atmospheric aerosols is a fundamental to understand the behavior of aerosols in the atmosphere. The analysis of atmospheric aerosols is the most preferable fields of the PIXE. In this paper, the characteristics of atmospheric aerosols are reviewed at first, and the sampling method of atmospheric aerosols for the PIXE samples and the characterization of atmospheric aerosols using the PIXE analysis are discussed. (author)

  20. Air pollution studies using PIXE and ICP methods

    International Nuclear Information System (INIS)

    Stihi, Claudia; Bancuta, Anca; Popescu, I V; Virgolici, M; Cimpoca, V; Gugiu, M; Vlaicu, Gh

    2006-01-01

    In the present work the moss biomonitoring technique and the combination of two analytical techniques - Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma (ICP) - were applied for assessing environmental situation from the point of view of air polluting along the transect from north to south of the Dambovita County. PIXE analysis at the Tandem Accelerator FN-8 of the National Institute of Nuclear Physics - Horia Hulubei of Magurele, Bucharest, allowed determination of P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd and Pb in samples. ICP analyses were made using a Baird ICP2070 - Sequential Plasma Spectrometer in Targoviste and we determined in samples the concentration of Li, B, Na, and Mg together with Cd and Pb. The obtained results will permit to determine the regional extent of heavy metals and toxic elements atmospheric pollution and to identify specially affected areas and local sources of

  1. PIXE studies of pollutants in plants

    International Nuclear Information System (INIS)

    Szymczyk, S.; Kajfosz, J.; Hrynkiewicz, A.; Curzydlo, J.

    1980-01-01

    Both industrial and road traffic pollutions were studied by PIXE by means of determination of trace elements accumulated in different plant tissues from affected areas. The method was improved by the application of an intermediate atmosphere in the target chamber. The PIXE method was proved to be adequate and convenient for monitoring many of the pollutants. (author)

  2. New results of GridPix TPCs

    International Nuclear Information System (INIS)

    Graaf, Harry van der

    2009-01-01

    The Gossip detector, being a GridPix TPC equipped with a thin layer of gas, is a promising alternative for Si tracking detectors. In addition, GridPix would be an interesting way to read out the gaseous phase volume of bi-phase Liquid Xe cryostats of v-less double beta decay and rare event (i.e. WIMP) search experiments.

  3. New results of GridPix TPCs

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Harry van der, E-mail: vdgraaf@nikhef.n [Science Park 105 1098 XG Amsterdam (Netherlands)

    2009-07-01

    The Gossip detector, being a GridPix TPC equipped with a thin layer of gas, is a promising alternative for Si tracking detectors. In addition, GridPix would be an interesting way to read out the gaseous phase volume of bi-phase Liquid Xe cryostats of v-less double beta decay and rare event (i.e. WIMP) search experiments.

  4. PIXE and {mu}-PIXE analysis of glazes from terracotta sculptures of the della Robbia workshop

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, Alessandro E-mail: zucc@ge.infn.it; Bouquillon, Anne; Lanterna, Giancarlo; Franco, Lucarelli; Mando, Pier Andrea; Prati, Paolo; Salomon, Joseph; Vaccari, Maria Grazia

    2002-04-01

    A series of PIXE analyses has been performed on glazes from terracotta sculptures of the Italian Renaissance and on reference standards. The problems related to the investigation of such heterogeneous materials are discussed and the experimental uncertainties are evaluated, for each element, from the PIXE analysis of standard glasses. Some examples from artefacts coming from Italian collections are given. This research has been conducted in the framework of the COST-G1 European action.

  5. PIXE and μ-PIXE analysis of glazes from terracotta sculptures of the della Robbia workshop

    International Nuclear Information System (INIS)

    Zucchiatti, Alessandro; Bouquillon, Anne; Lanterna, Giancarlo; Franco, Lucarelli; Mando, Pier Andrea; Prati, Paolo; Salomon, Joseph; Vaccari, Maria Grazia

    2002-01-01

    A series of PIXE analyses has been performed on glazes from terracotta sculptures of the Italian Renaissance and on reference standards. The problems related to the investigation of such heterogeneous materials are discussed and the experimental uncertainties are evaluated, for each element, from the PIXE analysis of standard glasses. Some examples from artefacts coming from Italian collections are given. This research has been conducted in the framework of the COST-G1 European action

  6. PIXE analysis of hair samples from artisanal mining communities in the Acupan region, Benguet, Philippines

    International Nuclear Information System (INIS)

    Clemente, Eligia; Sera, K.; Futatsugawa, S.; Murao, S.

    2004-01-01

    The mountainous regions of Benguet Province in the Philippines is home to some 10,000 small-scale miners who make out a living by extracting gold. In these communities, the method of extraction still involves the use of mercury, via amalgamation. In the separation of gold from mercury the method involves the release of mercury vapor into the atmosphere. This is therefore expected to affect the people living in the nearby areas. This study involves the accumulation of baseline data on the extent of mercury contamination in humans through the analysis of their hair. In 1989, Hursh et al. [Arch. Environ. Health 44 (2) (1989) 120] studied human volunteers and found that uptake of mercury vapor through the skin is only about 1% of the uptake through inhalation [World Health Organization, IPCS, EHC118, Inorganic Mercury, Geneva, 1991, p. 42]. In this light, any residual mercury which might have deposited in human hair is speculated to give an indication of how much mercury vapor the subject could have actually inhaled. A high concentration of mercury in the sample can therefore be indicative of the high rate of intake of the mercury vapor through inhalation. A sampling of the community consisted of both male (83%) and female (17%) subjects who ranged in age from 8 to 66 years old. Hair analysis was done using particle induced X-ray emission at the Iwate Medical University through Dr. Sera. With Zn set as a standard element, the rest of the elements were determined using the standard-free method. In order to obtain the conversion coefficient for hair samples, many hair samples were analyzed by this method and the internal standard method which involves the preparation of the hair samples by chemical ashing. The results obtained were comparable. The PIXE results for these samples showed the analysis of 26 elements but for our purposes, however, only the mercury analysis will be considered. Results of the analysis showed the hair samples to contain 0-27 ppm, with only seven

  7. Applications of external PIXE to ancient Egyptian artefacts

    International Nuclear Information System (INIS)

    Moser, M.; Bubb, I.F.; Johnston, N.; El Bouanani, M.; Stannard, W.B.; Short, R.C.

    1998-01-01

    The external Proton Induced X-Ray Emission (PIXE) facility at Royal Melbourne Institute of Technology has been used to analyse ancient Egyptian glass samples, an Egyptian wall paint fragment and soil pigments. A 0.35 mm diameter beam of 1.6 MeV protons, extracted from the vacuum through an 8 μm gold coated Kapton foil was used. Analysis of the spectra was carried out with the analysis package PIXAN. The analysis of two Egyptian glass samples enabled the partial determination of the colouring transition metals and the manufacturing technique, indicating them to be consistent with 'New Kingdom' glasses

  8. Characterization of impact materials around Barringer Meteor Crater by micro-PIXE and micro-SRXRF techniques

    Energy Technology Data Exchange (ETDEWEB)

    Uzonyi, I. E-mail: uzonyi@atomki.hu; Szoeor, Gy.; Rozsa, P.; Vekemans, B.; Vincze, L.; Adams, F.; Drakopoulos, M.; Somogyi, A.; Kiss, A.Z

    2004-06-01

    A combined micro-PIXE and micro-SRXRF method has been tested successfully for the characterization of impact materials collected at the well-known Barringer Meteor Crater. The micro-PIXE technique proved to be sensitive in the Z{<=}28 atomic number region while the micro-SRXRF above Fe especially for the siderophile elements. Quantitative analysis has become available for about 40 elements by these complementary methods providing new perspectives for the interpretation of the formation mechanism of impact metamorphosed objects.

  9. PIXE methodology of rare earth element analysis and its applications

    International Nuclear Information System (INIS)

    Ma Xinpei

    1992-01-01

    The Proton Induced X-ray Emission (PIXE) methodology of rare earth element (REEs) analysis is discussed, including the significance of REE analysis, the principle of PIXE applied to REE, selection of characteristic X-ray for Lanthanide series elements, deconvolution of highly over lapped PIXE spectrum and minimum detection limit (MDL) of REEs. Some practical applications are presented. And the specialities of PIXE analysis to the high pure REE chemicals are discussed. (author)

  10. A new small-footprint external-beam PIXE facility for cultural heritage applications using pulsed proton beams

    Science.gov (United States)

    Vadrucci, M.; Bazzano, G.; Borgognoni, F.; Chiari, M.; Mazzinghi, A.; Picardi, L.; Ronsivalle, C.; Ruberto, C.; Taccetti, F.

    2017-09-01

    In the framework of the COBRA project, elemental analyses of cultural heritage objects based on the particle induced X-ray emission (PIXE) are planned in a collaboration between the APAM laboratory of ENEA-Frascati and the LABEC laboratory of INFN in Florence. With this aim a 3-7 MeV pulsed proton beam, driven by the injector of the protontherapy accelerator under construction for the TOP-IMPLART project, will be used to demonstrate the feasibility of the technique with a small-footprint pulsed accelerator to Italian small and medium enterprises interested in the composition analysis of ancient artifacts. The experimental set-up for PIXE analysis on the TOP-IMPLART machine consists of a modified assembly of the vertical beam line usually dedicated to radiobiology experiments: the beam produced by the injector (RFQ + DTL, a PL7 ACCSYSHITACHI model) is bent to 90° by a magnet, is collimated by a 300 μm aperture inserted in the end nozzle and extracted into ambient pressure by an exit window consisting of a Upilex foil 7.5 μm thick. The beam is pulsed with a variable pulse duration of 20-100 μs and a repetition rate variable from 10 to 100 Hz. The X-ray detection system is based on a Ketek Silicon Drift Detector (SDD) with 7 mm2 active area and 450 μm thickness, with a thin Beryllium entrance window (8 μm). The results of the calibration of this new PIXE set-up using thick target standards and of the analysis of the preliminary measurements on pigments are presented.

  11. Calibration of PIXE-SP system of elementary analysis

    International Nuclear Information System (INIS)

    Tabacniks, M.H.

    1983-04-01

    The set-up and calibration of the PIXE-SP System of Elementary Analysis located at the Institute of Physics of the University of Sao Paulo is described. The PIXE-SP, that operates with 8 MeV alpha beam, has been calibrated for elements with Z >= 11, by means of homemade evaporated standard targets of Al, Si, Bacl 2 , K 2 CrO 4 , Ti, Cr, Mn, Fe, Cu, Ge, Ag, Sn, and Au. Those targets are thin, homogeneous, and have been calbrated on a microbalance within an average precision of 6%. The overall precision of the PIXE-SP System is estimated in 10% for elements with 16 2 thick, irradiated with a 10 μC electric charge, shows a minimum of about 0,1 ng (approximated 4 ppm) for Mn. The PIXE-SP System has also been intercalibrated with the PIXE located at University of Gent, Belgium, by means of 12 atmospheric aerosol targets collected on two Batelle Cascade Impactors. The analyzed masses of elements with 16 [pt

  12. Combined micro-PIXE and NIR Raman spectroscopic plaque characterisation in a human atherosclerotic aorta sample

    International Nuclear Information System (INIS)

    Brands, P.J.M.; Poll, S.W.E. van de; Quaedackers, J.A.; Mutsaers, P.H.A.; Puppels, G.J.; Laarse, A. van der; Voigt, M.J.A. de

    2001-01-01

    Raman spectroscopy can be applied to characterise the chemical composition of an atherosclerotic plaque in vivo. In the near future this technique may become available for use in (coronary) arteries of living patients. For this moment, Raman spectroscopy is applied on artery samples in vitro, to study progression and regression of atherosclerotic plaque. Raman spectroscopy provides chemical information on a molecular basis. In this study, micro-particle induced X-ray emission (micro-PIXE) is applied to provide additional information on the elemental composition of the artery. Furthermore, the combined techniques allow for validation of the structures studied with Raman spectroscopy. This study proves that it is possible to combine and compare both techniques using the same region on the same sample if proper sample preparation is applied. Comparison shows that regions appearing in the Raman spectroscopy results can also be distinguished in micro-PIXE and backscattering spectroscopy (BS) distributions and vice versa. Combining both techniques makes it possible to separate phospholipids from triglycerides. Combined Raman spectroscopy and micro-PIXE/BS is recommended for studying progression and regression of atherosclerosis

  13. PIXAN: the Lucas Heights PIXE analysis computer package

    International Nuclear Information System (INIS)

    Clayton, E.

    1986-11-01

    To fully utilise the multielement capability and short measurement time of PIXE it is desirable to have an automated computer evaluation of the measured spectra. Because of the complex nature of PIXE spectra, a critical step in the analysis is the data reduction, in which the areas of characteristic peaks in the spectrum are evaluated. In this package the computer program BATTY is presented for such an analysis. The second step is to determine element concentrations, knowing the characteristic peak areas in the spectrum. This requires a knowledge of the expected X-ray yield for that element in the sample. The computer program THICK provides that information for both thick and thin PIXE samples. Together, these programs form the package PIXAN used at Lucas Heights for PIXE analysis

  14. PIXE application to the study of atmospheric aerosol

    International Nuclear Information System (INIS)

    Zhu Guanghua

    1998-11-01

    In order to confirm the measurement accuracy of PIXE (Particle Induced X-ray Emission), cross-check test were carried out between three laboratories. Thirty single element samples and one plural elements sample were used in the test. The agreements between three laboratories were evaluated to be better than 10% for the most of tested samples. The reproducibility test showed very good agreement and the dispersion in three times repeated PIXE measurements was within 6% on average. Using an automatic time sequence step sampler in Beijing collected atmospheric aerosol samples. Element concentrations were analyzed by PIXE technique. Then the data were analyzed by the absolute principal factor analysis (APFA) to evaluate the principal components and the percent variance explained by them. As a result, it shows that the PIXE analysis combed with statistical method can effectively resolve the aerosol components in urban area and distinguish between local and remote area aerosol components. The atmospheric aerosol samples were collected at four representative sites with an 8-stage cascade impactor sampler and analyzed for their elemental mass concentrations by PIXE analytic method. Based on some indicator elements, the characteristics of size distributions of particles from different sources were obtained

  15. Study on atmosphere pollution by PIXE analysis combining with statistical method

    International Nuclear Information System (INIS)

    Zhu Guanghua

    1994-06-01

    Atmospheric aerosol samples were collected using an 8-stage cascade impactor or an automatic time sequence step sampler at Jomo Langma, Zhangye at the edge of Gobi Desert and Beijing. Element concentration were analyzed by PIXE (proton induced X-ray emission) technique. The data were analyzed by APCA (absolute principal component analysis) to determine the principal components. The sources and contribution to the aerosol in the above three regions were discussed. The result shows that the PIXE has high sensitivity, multi-element capability, high speed and non-destruction advantages. APCA analytical method can effectively determine the aerosol components in urban area, and it also can distinguish between local components and remote components in the area far from the pollution resources

  16. GridPix application to dual phase TPC

    NARCIS (Netherlands)

    Alfonsi, M.; van Bakel, N.; Colijn, A.-P.; Decowski, M.P.; van der Graaf, H.; Schön, R.; Tiseni, A.

    2013-01-01

    GridPix is a gas-filled detector with an aluminium mesh stretched 50 μm above the Timepix CMOS pixel chip. This defines a high electric field where gas amplification occurs. A feasibility study is ongoing at Nikhef for the application of the GridPix technology as a charge sensitive device in a dual

  17. Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications)

    Energy Technology Data Exchange (ETDEWEB)

    Pinsky, Lawrence S., E-mail: pinsky@uh.edu [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Empl, Anton [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Gutierrez, Andrea [University of Montreal, 2905 Chemin des services, Montreal, Que., H3T 1J4 (Canada); Jakubek, Jan [Institute of Experimental and Applied Physics, Czech Technical University, Horska 3a/22, CZ-12800 Prague 2-Albertov (Czech Republic); Kitamura, Hisashi [National Institute for Radiological Sciences, Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Miller, Jack [Space Sciences Laboratory, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Leroy, Claude [University of Montreal, 2905 Chemin des services, Montreal, Que., H3T 1J4 (Canada); Stoffle, Nicholas [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Pospisil, Stanislav [Institute of Experimental and Applied Physics, Czech Technical University, Horska 3a/22, CZ-12800 Prague 2-Albertov (Czech Republic); Uchihori, Yukio; Yasuda, Nakahiro [National Institute for Radiological Sciences, Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Zeitlin, Cary [Southwest Research Institute, 6220 Culebra Rd., San Antonio, TX 78238-5166 (United States)

    2011-05-15

    Exposures were made with Medipix2 TimePix-based Si detectors at the HIMAC facility in Japan to explore the potential for discrimination between tracks with differing charges and energies, but with very similar dE/dx values. Data were taken at 15 deg. increments for a number of different beams including 600 and 800 MeV/A Si, 180 MeV/A Ne and 100 MeV/A O. Data were also obtained for 400 MeV/A Si and 500 MeV/A Fe along with 290 and 180 MeV/A N. The TimePix chips have been calibrated to achieve the maximum resolution. Estimates for the angular resolution for these types of tracks are also possible from these data, which are essential in the development of a TimePix-based dosimetric device for use in a space radiation environment. One of the principal objectives of these data runs was to explore the resolution of TimePix-based Si detectors to discriminate between various ions with different energies and charges, but with similar dE/dx values in Si. Analysis of the images obtained shows the clear differences in the {delta}-ray halos for particles with similar dE/dx values but for differing charges and energies. These measurements are part of an ongoing program to explore the range of capabilities of the TimePix-based detector with respect to dosimetry uses in space.

  18. PIXE characterization of Western Mediterranean and Anatolian obsidians and Neolithic provenance studies

    International Nuclear Information System (INIS)

    Le Bourdonnec, F.-X.; Delerue, S.; Dubernet, S.; Moretto, Ph.; Calligaro, Th.; Dran, J.-C.; Poupeau, G.

    2005-01-01

    The possibility of non-destructive elemental analysis makes PIXE a very attractive technique in archaeological provenance studies. This technique has been fruitfully implemented on two different facilities to address the issue of obsidian provenance in the Mediterranean and in surrounding regions. At C2RMF, we took advantage of the possibility to analyze large archaeological pieces with the external micro-beam set-up. At CENBG, we used the nuclear microprobe providing a 5 μm beam diameter in large scans (700 x 700 μm 2 ) to control the homogeneity of elemental distribution. In both cases we dosed the same set of 13 elements: Na, Al, Si, K, Ca, Ti, Mn, Fe, Zn, Ga, Rb, Sr and Zr. While at C2RMF, two Si(Li) detectors were used simultaneously to measure all elements at once with 3 MeV protons, at CENBG where only one detector was available, the light elements Na to Fe were determined with a 1.5 MeV beam, and the heavy ones, including Fe, with a beam energy of 2.7 MeV. In Western Mediterranean, it is possible with PIXE to differentiate all obsidian sources of archaeological significance. Examples are given of obsidian provenances from Neolithic sites of France and from the islands of Corsica and Sardinia. In the Near East, we can differentiate the Cappadocian and Eastern Anatolian obsidian sources used during the early Neolithic. This is illustrated by examples taken from Neolithic sites of the Middle Euphrates Valley (Syria)

  19. PIXE determination of Pb in wine

    International Nuclear Information System (INIS)

    Kocsonya, A.; Guguianu, O.; Demeter, I.; Hollos-Nagy, Katalin; Kovacs, I.; Szokefalvi-Nagy, Z.

    2002-01-01

    The permissible level of the Pb content in wine varies in the range of 200-300 μg/l in different countries. These values are below the detection limit for standard PIXE spectrometry. Initiated by an intercomparison action of The International Measurement Evaluation Programme (IMEP, Geel, Belgium), an attempt was made to lower the detection limit of PIXE without introducing any additional chemical steps. Wine samples of 5 ml were gradually condensed below an infrared lamp and 8 μl aliquots were taken from time to time and pipetted onto filter paper. The samples were analysed by standard PIXE technique, with the analyte addition method used for calibration. A detection limit of about 50 ppb was finally achieved. Comparing this value to the permissible levels, this simple and fast technique can be used for screening purposes. As an application, the lead content of three Hungarian market wines was also measured

  20. PIXE determination of Pb in wine

    Energy Technology Data Exchange (ETDEWEB)

    Kocsonya, A.; Guguianu, O.; Demeter, I.; Hollos-Nagy, Katalin; Kovacs, I.; Szokefalvi-Nagy, Z. E-mail: sznagy@rmki.kfki.hu

    2002-04-01

    The permissible level of the Pb content in wine varies in the range of 200-300 {mu}g/l in different countries. These values are below the detection limit for standard PIXE spectrometry. Initiated by an intercomparison action of The International Measurement Evaluation Programme (IMEP, Geel, Belgium), an attempt was made to lower the detection limit of PIXE without introducing any additional chemical steps. Wine samples of 5 ml were gradually condensed below an infrared lamp and 8 {mu}l aliquots were taken from time to time and pipetted onto filter paper. The samples were analysed by standard PIXE technique, with the analyte addition method used for calibration. A detection limit of about 50 ppb was finally achieved. Comparing this value to the permissible levels, this simple and fast technique can be used for screening purposes. As an application, the lead content of three Hungarian market wines was also measured.

  1. Grazing-incident PIXE Analysis Technology

    International Nuclear Information System (INIS)

    Li Hongri; Wang Guangpu; Liang Kun; Yang Ru; Han Dejun

    2009-01-01

    In the article, the grazing incidence technology is first applied to the PIXE (proton induced X-ray emission) analysis. Three pieces of samples were investigated, including the contaminated aluminium substrate, the SIMOX (separated by oxygen implantation) SOI (Silicon on Insulator) sample and the silicon wafer implanted with Fe + . The results reveal that the grazing-incident proton can improve the sensitivity of PIXE in trace analysis, especially for samples contaminated on surface. With the penetration depth of the proton bean decreased, the ratio of the peak area to the detection limit raised observably and the sensitivity near the sample surface increased. (authors)

  2. Trace-Element Analysis by Use of PIXE Technique on Agricultural Products

    Science.gov (United States)

    Takagi, A.; Yokoyama, R.; Makisaka, K.; Kisamori, K.; Kuwada, Y.; Nishimura, D.; Matsumiya, R.; Fujita, Y.; Mihara, M.; Matsuta, K.; Fukuda, M.

    2009-10-01

    In order to examine whether a trace-element analysis by PIXE (Particle Induced X-ray Emission) gives a clue to identify production area of agricultural products, we carried out a study on soy beans as an example. In the present study, a proton beam at the energy of 2.3MeV was provided by Van de Graaff accelerator at Osaka University. We used a Ge detector with Be window to measure X-ray spectra. We prepared sample soy beans from China, Thailand, Taiwan, and 7 different areas in Japan. As a result of PIXE analysis, 5 elements, potassium, iron, zinc, arsenic and rubidium, have been identified. There are clear differences in relative amount of trace-elements between samples from different international regions. Chinese beans contain much more Rb than the others, while there are significant differences in Fe and Zn between beans of Thailand and Taiwan. There are relatively smaller differences among Japanese beans. This result shows that trace-elements bring us some practical information of the region where the product grown.

  3. Intercomparison of PIXE spectrometry software packages

    International Nuclear Information System (INIS)

    2003-02-01

    During the year 2000, an exercise was organized to make a intercomparison of widely available software packages for analysis of particle induced X ray emission (PIXE) spectra. This TECDOC describes the method used in this intercomparison exercise and presents the results obtained. It also gives a general overview of the participating software packages. This includes basic information on their user interface, graphical presentation capabilities, physical phenomena taken in account, way of presenting results, etc. No recommendation for a particular software package or method for spectrum analysis is given. It is intended that the readers reach their own conclusions and make their own choices, according to their specific needs. This TECDOC will be useful to anyone involved in PIXE spectrum analysis. This TECDOC includes a companion CD with the complete set of test spectra used for intercomparison. The test spectra on this CD can be used to test any PIXE spectral analysis software package

  4. Investigation of in vivo PIXE effect within superficial tumor model of high-Z metalnanoplatform for PIXE-based proton therapy

    International Nuclear Information System (INIS)

    Kim, Jong Ki; Seo, Seung Jun; Lee, Ju Hong

    2010-04-01

    Metallic nanoparticles (MNP) are able to release localized X-ray when activated with high energy proton beam by particle induced X-ray emissions (PIXE) effect. The exploitation of this phenomenon in the therapeutic irradiation of tumors has been investigated. PIXE-based X-ray emission directed at CT-26 tumor cells in vitro, when administered with either gold (average diameter, 2 nm and 13 nm) or iron (average diameter, 14 nm) nanoparticles, increased with MNP solution concentration over the range of 0.1-2 mg/mL. With irradiation by 45-MeV proton therapy (PT) beam, higher concentrations had a decreased cell survival fraction. An in vivo study with tumor regression assay demonstrated significant tumor dose enhancement, thought to be result of the PIXE effect when compared to conventional PT without MNP using a 45 MeV proton beam (p<0.01). These effects were observed for gold and iron MNP, injected in doses of 100-300mg/kg body weight into CT-26 mouse tumor models via tail vein. A therapeutic effective MNP concentration range, in vivo,was estimated at 30-79 μg/g tissue for both gold and iron nanoparticles. The tumor dose enhancement may compensate for an increase in entrance dose associated with conventional PT when treating large, solid tumors with a spread out Bragg peak (SOBP) technique. The use of combined high energy Bragg peak PT with PIXE generated by MNP, or PIXE alone may result in new treatment options for infiltrative metastatic tumors and other diffuse inflammatory diseases

  5. Silicon Drift Detector response function for PIXE spectra fitting

    Science.gov (United States)

    Calzolai, G.; Tapinassi, S.; Chiari, M.; Giannoni, M.; Nava, S.; Pazzi, G.; Lucarelli, F.

    2018-02-01

    The correct determination of the X-ray peak areas in PIXE spectra by fitting with a computer program depends crucially on accurate parameterization of the detector peak response function. In the Guelph PIXE software package, GUPIXWin, one of the most used PIXE spectra analysis code, the response of a semiconductor detector to monochromatic X-ray radiation is described by a linear combination of several analytical functions: a Gaussian profile for the X-ray line itself, and additional tail contributions (exponential tails and step functions) on the low-energy side of the X-ray line to describe incomplete charge collection effects. The literature on the spectral response of silicon X-ray detectors for PIXE applications is rather scarce, in particular data for Silicon Drift Detectors (SDD) and for a large range of X-ray energies are missing. Using a set of analytical functions, the SDD response functions were satisfactorily reproduced for the X-ray energy range 1-15 keV. The behaviour of the parameters involved in the SDD tailing functions with X-ray energy is described by simple polynomial functions, which permit an easy implementation in PIXE spectra fitting codes.

  6. Investigation on trace and major elements in anti-asthmatic medicinal plants by PIXE and PIGE techniques

    Science.gov (United States)

    Bhanisana Devi, R. K.; Nandakumar Sarma, H.; Kumar, Sanjiv

    2015-01-01

    Five widely used anti-asthmatic medicinal plants of north-eastern region of India have been investigated by using Proton Induced X-ray Emission (PIXE) and Proton Induced Gamma ray Emission (PIGE) techniques. The elements namely K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se and Br were detected with different concentrations (in ppm level) by PIXE technique whereas light elements namely F, Na, Mg, Al, P and Cl by PIGE technique in the studied plants. No toxic heavy metals such as Hg, Pb, Cd were detected. Analysis was performed on thick targets (pellets) prepared using the powders of specimens through a series of processing steps. Thick targets of plant based Certified Reference Materials (CRMs) were served as standardization of PIXE and PIGE set up. The trace elements present in the studied plants have been correlated with their medicinal properties.

  7. Investigation on trace and major elements in anti-asthmatic medicinal plants by PIXE and PIGE techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bhanisana Devi, R.K., E-mail: bhanisanark@gmail.com [Department of Physics, Manipur University, Canchipur 795003 (India); Nandakumar Sarma, H. [Department of Physics, Manipur University, Canchipur 795003 (India); Kumar, Sanjiv [National Centre for Compositional Characterization of Materials (NCCCM), Hyderabad 500062 (India)

    2015-01-15

    Five widely used anti-asthmatic medicinal plants of north-eastern region of India have been investigated by using Proton Induced X-ray Emission (PIXE) and Proton Induced Gamma ray Emission (PIGE) techniques. The elements namely K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se and Br were detected with different concentrations (in ppm level) by PIXE technique whereas light elements namely F, Na, Mg, Al, P and Cl by PIGE technique in the studied plants. No toxic heavy metals such as Hg, Pb, Cd were detected. Analysis was performed on thick targets (pellets) prepared using the powders of specimens through a series of processing steps. Thick targets of plant based Certified Reference Materials (CRMs) were served as standardization of PIXE and PIGE set up. The trace elements present in the studied plants have been correlated with their medicinal properties.

  8. PIXE study on the provenance of Chinese ancient porcelain

    International Nuclear Information System (INIS)

    Zhu, D.; Cheng, H.S.; Lin, J.W.; Yang, F.J.

    2006-01-01

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE

  9. PIXE study on the provenance of Chinese ancient porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, D. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China); Cheng, H.S. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Lin, J.W. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, 220 Handan Road, Shanghai 200433 (China)

    2006-08-15

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.

  10. PIXE study on the provenance of Chinese ancient porcelain

    Science.gov (United States)

    Zhu, D.; Cheng, H. S.; Lin, J. W.; Yang, F. J.

    2006-08-01

    This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.

  11. A dual-PIXE tomography setup for reconstruction of Germanium in ICF target

    Science.gov (United States)

    Guo, N.; Lu, H. Y.; Wang, Q.; Meng, J.; Gao, D. Z.; Zhang, Y. J.; Liang, X. X.; Zhang, W.; Li, J.; Ma, X. J.; Shen, H.

    2017-08-01

    Inertial Confinement Fusion (ICF) is one type of fusion energy research which could initiate nuclear fusion reactions through heating and compressing thermonuclear fuel. Compared to a pure plastic target, Germanium doping into the CH ablator layer by Glow Discharge Polymer (GDP) technique can increase the ablation velocity and the standoff distance between the ablation front and laser-deposition region. During target fabrication process, quantitative doping of Ge should be accurately controlled. Particle Induced X-ray Emission Tomography (PIXE-T) can make not only quantification of the concentration, but also reconstruction of the spatial distribution of doped element. The Si (Li) detector for PIXE tomography technique had a disadvantage of low counting rate. To make up this deficiency, another detector of Si (Li) with the same configuration positioned at the opposite side with the same detective angle 135° have been implemented. Simultaneously acquired elemental maps of Ge obtained using two detectors may be different because of the X-ray absorption along the X-ray exit route in the target. In this paper, the X-ray detection efficiency is drastically improved by this dual-PIXE tomography system.

  12. PIXE macro and microprobe techniques in archaeometry

    International Nuclear Information System (INIS)

    Brissaud, I.; Lagarde, G.; Houdayer, A.

    1987-01-01

    PIXE analysis method is applied to archaeometry problems. Advantages and disadvantages are emphasized. Some examples are presented which show the difficulties: especially important heterogeneities of ceramics, old coins and metals restrain from the use of this technique. Other analysis systems, less expensive, like electron microbrobe or x-ray fluorescence spectrometry, are compared with conventional PIXE method. The importance of proton microprobe is explained. (author) 40 refs.; 7 figs.; 5 tabs

  13. PIXE analysis on Maya blue in Prehispanic and colonial mural paintings

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez del Rio, M. [Departamento de Fisica, Universidad Autonoma Metropolitana, Iztapalapa, DF 09340 (Mexico); Martinetto, P. [Laboratoire de Cristallographie, CNRS, BP 166, F-30842 Grenoble (France); Solis, C. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Mexico, DF 04510 (Mexico)]. E-mail: corina@fisica.unam.mx; Reyes-Valerio, C. [Instituto Nacional de Antropologi' a e Historia, Mexico, DF (Mexico)

    2006-08-15

    Particle induced X-ray emission (PIXE) experiments have been carried out at the AGLAE facility (Paris) on several mural samples containing Maya blue from different Prehispanic archaeological sites (Cacaxtla, El Tajin, Tamuin, Santa Cecilia Acatitlan) and from several colonial convents in the Mexican plateau (Jiutepec, Totimehuacan, Tezontepec and Cuauhtinchan). The analysis of the concentration of several elements permitted to extract some information on the technique used for painting the mural, usually fresco. Principal component analysis permitted to classify the samples into groups. This grouping is discussed in relation to geographic and historic data.

  14. Archaeological obsidian from La Sierra Gorda Mexico, by PIXE

    International Nuclear Information System (INIS)

    Juarez-Cossio, D.; Terreros, E.; Quiroz-Moreno, J.; Romero-Sanchez, S.; Calligaro, T.F.; Tenorio, D.; Jimenez-Reyes, M.; Los Rios, M. de

    2009-01-01

    The chemical compositions of 42 obsidian pre-Hispanic artifacts from Tancama and Purisima, both archaeological sites of La Sierra Gorda Valleys, Mexico, were analyzed by PIXE technique. These obsidians came from four sources: Sierra de Pachuca Hidalgo, Paraiso Queretaro, Ucareo Michoacan and mainly from Zacualtipan/Metzquititlan Hidalgo. According to archaeological evidences, La Sierra Gorda valleys participated in commercial exchange with other regional sites, from Classic to Post-classic periods (A.D. 300-1500).

  15. Present role of PIXE in atmospheric aerosol research

    Energy Technology Data Exchange (ETDEWEB)

    Maenhaut, Willy, E-mail: Willy.Maenhaut@UGent.be

    2015-11-15

    In the 1980s and 1990s nearly half of the elemental analyses of atmospheric aerosol samples were performed by PIXE. Since then, other techniques for elemental analysis became available and there has been a steady increase in studies on organic aerosol constituents and other aspects of aerosols, especially in the areas of nucleation (new particle formation), optical properties, and the role of aerosol particles in cloud formation and properties. First, a brief overview and discussion is given of the developments and trends in atmospheric aerosol analysis and research of the past three decades. Subsequently, it is indicated that there is still invaluable work to be done by PIXE in atmospheric aerosol research, especially if one teams up with other aerosol researchers and performs complementary measurements, e.g., on small aerosol samples that are taken with high-time resolution. Fine examples of such research are the work done by the Lund group in the CARIBIC aircraft studies and the analysis of circular streaker samples by the Florence PIXE group. These and other examples are presented and other possibilities of PIXE are indicated.

  16. Elemental PIXE analysis of oolong tea

    International Nuclear Information System (INIS)

    Watanabe, M.; Ishii, K.; Matsuyama, S.

    2008-01-01

    The contamination of heavy metals in food becomes a serious problem. We analyzed oolong tea from different production areas by PIXE using very simple sample preparation and examined trace elements contained in these samples. From the results of this experiment, we could know oolong tea which analyzed in this experiment contains various minerals such as K, Ca, P, S, Cl, Fe, Mn, Cu and Cr but not toxic element of As which detection limit of PIXE was lower than the standard values given by the food hygiene law in Japan. (author)

  17. PIXE analysis of vehicle exhaust particulate

    International Nuclear Information System (INIS)

    Shi Xianfeng; Yao Huiying; Liu Bo; Sun Minde; Xu Huawei; Mi Yong; Shen Hao

    2001-01-01

    PIXE technique on the analysis of vehicle exhaust particulate is introduced. The clement composition and concentration of particulate are obtained. Some elements which are related to environmental pollution such as sulfur lead, silicon and manganese, were analyzed and discussed in detail by PIXE technique Nowadays although unleaded gasoline is widely used, the lead concentration is still very high in exhaust particulate. The concentrations of silicon and manganese in exhaust particulate from different model vehicles are also quite high from measurements. It shows that an evidence for exhaust pollution control could be provided from this work

  18. The LLNL Multi-User Tandem Laboratory PIXE microprobe

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Bench, G.S.; Antolak, A.J.; Morse, D.H.; Pontau, A.E.

    1992-01-01

    We have recently completed the construction of a new ion beamline primarily for particle-induced x-ray emission (PIXE) analysis. This will supplement our current ion microtomography (IMT) material characterization capabilities using accelerator microanalysis. In this paper we describe the PIXE beamline and give some results that characterize the system. We also report the results of some initial experiments

  19. Evaluation and mapping of PM{sub 2.5} atmospheric aerosols in Arasia region using PIXE and gravimetric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Roumie, M. [Accelerator Laboratory, Lebanese Atomic Energy Commission, CNRSL, Beirut (Lebanon); Chiari, M. [INFN, Firenze and Department of Physics and Astronomy, University of Florence, Florence (Italy); Srour, A. [Accelerator Laboratory, Lebanese Atomic Energy Commission, CNRSL, Beirut (Lebanon); Sa’adeh, H. [Department of Physics, Faculty of Science, University of Jordan, Amman (Jordan); Reslan, A. [Accelerator Laboratory, Lebanese Atomic Energy Commission, CNRSL, Beirut (Lebanon); Sultan, M. [Ministry of Science and Technology MOST, Baghdad (Iraq); Ahmad, M. [Atomic Energy Commission of Syria AECS, Damascus (Syrian Arab Republic); Calzolai, G.; Nava, S. [INFN, Firenze and Department of Physics and Astronomy, University of Florence, Florence (Italy); Zubaidi, Th. [Ministry of Science and Technology MOST, Baghdad (Iraq); Rihawy, M.S. [Atomic Energy Commission of Syria AECS, Damascus (Syrian Arab Republic); Hussein, T. [Department of Physics, Faculty of Science, University of Jordan, Amman (Jordan); Department of Physics, Division of Atmospheric Sciences, University of Helsinki, Helsinki (Finland); Arafah, D.-E. [Department of Physics, Faculty of Science, University of Jordan, Amman (Jordan); Karydas, A.G.; Simon, A. [International Atomic Energy Agency IAEA, Vienna (Austria); Nsouli, B. [Accelerator Laboratory, Lebanese Atomic Energy Commission, CNRSL, Beirut (Lebanon)

    2016-03-15

    The present work is a part of a scientific study conducted among several Arab countries in west Asia, under an International Atomic Energy Agency (IAEA) regional technical cooperation project for Arasia region. The project aims at producing for the first time a database of particulate matter (PM) elemental concentrations in the region that will help in future air quality studies in order to identify commonalities and differences in the presence and contribution of fingerprint pollution sources among the Arasia Member States. The first regional campaign was launched simultaneously in Lebanon, Iraq, Jordan, Syria and United Arab Emirates, using a harmonized sampling and analysis protocol of PM{sub 10} and PM{sub 2.5} samples. Different samples, collected between October 2014 and February 2015, from the participating countries, were analyzed by PIXE technique and gravimetric measurements were also carried out. The first results of the study will be discussed in a regional perspective. Our study shows that concentrations of fine aerosol fractions are often exceeding the WHO standard values as well as showing some disparities in the obtained values between the different sampling sites. However, some trend similarities of variations with time could also be observed, suggesting a common influence by trans-boundary or external sources of air pollution.

  20. The bio-PIXE setup on the Debrecen scanning proton microprobe

    International Nuclear Information System (INIS)

    Kertesz, Zs.; Szikszai, Z.; Uzonyi, I.; Simon, A.; Kiss, A.Z.

    2004-01-01

    Complete text of publication follows. Besides the ongoing applications in archeometry, geology, material science and atmospheric aerosol study, in recent years the IBA Group in Debrecen has joined several biological and biomedical research projects. Such studies require the knowledge of accurate quantitative elemental concentrations and distributions in organic, inhomogeneous thin samples on a microscopic scale. In most cases, to carry out quantitative investigations on biomedical samples down to the cell level, the combination of proton induced X-ray emission (PIXE), Rutherford backscattering (RBS) spectrometry and scanning transmission ion microscopy (STIM) analytical methods are used simultaneously. STIM provides information on the density and structure of the sample, PIXE measures the concentration of the inorganic major and trace elements, and finally RBS serves to characterize the organic matrix, to determine the beam dose, and sometimes the sample thickness. The drawback of this combined method is that to evaluate the RBS data the hydrogen to carbon ratio in the sample must be known. The setup developed at the Debrecen microprobe facility [1] is based on the combined application of on-axis STIM and simultaneous PIXE-PIXE analytical techniques. In the PIXE-PIXE method the sample matrix is determined directly by measuring X-rays from all elements in the sample including the light elements such as carbon and oxygen, using two Si(Li) X-ray detectors. In this arrangement an ultra thin windowed Si(Li) X-ray detector serves to characterize the matrix by measuring low energy X-ray lines (0.2-9 keV) while a large area Be-windowed detector is used to detect the medium and high energy X-ray lines (>4 keV). In this way elements with atomic number higher than 5 can be detected simultaneously, reducing both radiation damage of the sample and measurement time. In addition, the knowledge of the hydrogen content of the sample is not needed, since it influences the

  1. Regional energy facility siting analysis

    International Nuclear Information System (INIS)

    Eberhart, R.C.; Eagles, T.W.

    1976-01-01

    Results of the energy facility siting analysis portion of a regional pilot study performed for the anticipated National Energy Siting and Facility Report are presented. The question of cell analysis versus site-specific analysis is explored, including an evaluation of the difference in depth between the two approaches. A discussion of the possible accomplishments of regional analysis is presented. It is concluded that regional sitting analysis could be of use in a national siting study, if its inherent limits are recognized

  2. Unriddling of ancient-medieval culture by PIXE

    International Nuclear Information System (INIS)

    Uda, M.

    1997-01-01

    Some examples are given for unriddling of ancient-medieval culture by PIXE. Effectiveness of PIXE to analyze art and archaeological objects is also explained. Objects employed here are 1) red, yellow, blue and white pigments painted on sun-dried bricks excavated in Egypt, 2) ancient glass beads used in the Near East, 3) South American mummy hair, 4) ancient slag excavated from Kansai-district, Japan 5) ink used by Galileo Galilei and 6) Renaissance style enameled gold jewelry. (author)

  3. PIXE applications to the toxicological field

    Energy Technology Data Exchange (ETDEWEB)

    Santos, C.E.I. dos; Dias, J.F.; Jobim, P.F.C.; Yoneama, M.L. [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Instituto de Fisica. Laboratorio de Implantacao Ionica; Andrade, V.M. [Universidade do Extremo Sul Catarinense, Criciuma, SC (Brazil). Laboratorio de Biologia Celular e Molecular; Amaral, L.; Silva, J. da [Universidade Luterana do Brasil, Canoas, RS (Brazil). Laboratorio de Toxicologia Generica

    2013-07-01

    Full text: Several studies have been carried out in order to investigate the toxicological properties of some chemical elements in different type of biological samples. lon beam techniques, in particular PIXE, have been successfully used to analyze the elemental composition of food, beverage, plants and animal tissues. In this context, the PIXE line of the lon Implantation Laboratory (Porto Alegre, Brazil) have been used in the last few years to study food and beverage processing and biological specimens exposed to contaminated environment. The aim of this study is to present some of our results using PIXE analysis applied to toxicological research field. For instance, a recent published research [1] investigated the genotoxic and mutagenic effects in tobacco farmers exposed to metal-based formulated pesticides. Levels of Mg, AI, CI, Zn, Cr and Br, elements associated with DNA damage, were higher in the blood samples of tobacco farmers exposed to pesticide than in the non-exposed group. The occupational genotoxicity among copper smelters was also investigated [2]. The elemental content of blood samples were analyzed by PIXE. DNA damage in the peripheral blood Iymphocytes of workers exposed to copper smelter was observed. However, no clear correlation was found between the metal content and DNA damage. [1] F. R. da Silva, J. da Silva, M. C. AlIgayer, C. F. Simon, J. F. Dias, C. E. I. dos Santos, M. Salvador, C. Branco, N. B. Schneider, V. Kahl, P. Rohr, K. Kvitko, J. Hazard. Mat., 225-226 (2012) 81-90. (author)

  4. PIXE applications to the toxicological field

    International Nuclear Information System (INIS)

    Santos, C.E.I. dos; Dias, J.F.; Jobim, P.F.C.; Yoneama, M.L.; Andrade, V.M.; Amaral, L.; Silva, J. da

    2013-01-01

    Full text: Several studies have been carried out in order to investigate the toxicological properties of some chemical elements in different type of biological samples. lon beam techniques, in particular PIXE, have been successfully used to analyze the elemental composition of food, beverage, plants and animal tissues. In this context, the PIXE line of the lon Implantation Laboratory (Porto Alegre, Brazil) have been used in the last few years to study food and beverage processing and biological specimens exposed to contaminated environment. The aim of this study is to present some of our results using PIXE analysis applied to toxicological research field. For instance, a recent published research [1] investigated the genotoxic and mutagenic effects in tobacco farmers exposed to metal-based formulated pesticides. Levels of Mg, AI, CI, Zn, Cr and Br, elements associated with DNA damage, were higher in the blood samples of tobacco farmers exposed to pesticide than in the non-exposed group. The occupational genotoxicity among copper smelters was also investigated [2]. The elemental content of blood samples were analyzed by PIXE. DNA damage in the peripheral blood Iymphocytes of workers exposed to copper smelter was observed. However, no clear correlation was found between the metal content and DNA damage. [1] F. R. da Silva, J. da Silva, M. C. AlIgayer, C. F. Simon, J. F. Dias, C. E. I. dos Santos, M. Salvador, C. Branco, N. B. Schneider, V. Kahl, P. Rohr, K. Kvitko, J. Hazard. Mat., 225-226 (2012) 81-90. (author)

  5. PIXE analysis of atmospheric particulate matter in glas fibre filters

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Orsini, C.Q.; Maenhaut, W.

    1993-01-01

    A 3-step extraction procedure was developed to allow particle-induced X-ray emission (PIXE) analysis of particulate matter in normal glass fibre filter samples. The detection limits, expressed in ng/m 3 of air, for the filter extracts were 5 to 30 times lower than those achieved by PIXE analysis or ordinary Nuclepore polycarbonate filter samples. The concentration results were compared with those obtained from routine atomic absorption spectrometry measurements and with the PIXE data from Nuclepore stacked filter unit samples taken in parallel. (orig.)

  6. PIXE analysis on Maya blue in Prehispanic and colonial mural paintings

    Science.gov (United States)

    Sánchez del Río, M.; Martinetto, P.; Solís, C.; Reyes-Valerio, C.

    2006-08-01

    Particle induced X-ray emission (PIXE) experiments have been carried out at the AGLAE facility (Paris) on several mural samples containing Maya blue from different Prehispanic archaeological sites (Cacaxtla, El Tajín, Tamuin, Santa Cecilia Acatitlán) and from several colonial convents in the Mexican plateau (Jiutepec, Totimehuacán, Tezontepec and Cuauhtinchán). The analysis of the concentration of several elements permitted to extract some information on the technique used for painting the mural, usually fresco. Principal component analysis permitted to classify the samples into groups. This grouping is discussed in relation to geographic and historic data.

  7. Non-destructive analysis and identification of jade by PIXE

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, Z.Q.; Zhang, B.; Yang, F.J.

    2004-01-01

    This paper reports the experimental results of identifying jade by proton induced X-ray emission (PIXE) technique. It is found that the jade can be classified, according to the chemical composition determined by PIXE. The experimental results can differentiate ancient Chinese jade works of art from fakes if the material is the same

  8. Determination of some heavy metals in wetlands by PIXE; Determinacion de algunos metales pesados en jales por medio de PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez O, J.; Rios M, C. [UAZ, 98160 Zacatecas (Mexico)

    2008-07-01

    In this work the results of the analysis are presented, using the PIXE technique (Proton Induced X-ray Emission), in soil samples of the El Bordo, Vetagrande, Zacatecas, before and after subjecting them to a lixiviation process for the recovering of gold, silver and mercury. This community is part of the mining region nearer to the Zacatecas city municipality, region in which the mining exploitation dates from the colonial time. During almost 350 years the 'yard benefit' method was used or amalgamation with mercury, process that besides having used big quantities of mercury, generated a great quantity of mineral waste calls 'mine wetlands', those that were accumulating, crawled by the rains, toward the streams that end in the prey 'The Pedernalillo'. The dispersion of wetlands them it has extended from the prey until the communities of Tacoaleche, Zoquite, Lampotal and El Bordo, embracing an approximate area of 16 x 2 Km{sup 2} and forming with the course of the time an accumulated of several millions of tons. In order to determining if the process of recovery of gold, silver and mercury make soluble to other contained metals in these wastes, samples were gathered in an area of 600 m{sup 2} in the community of The Border, Vetagrande, Zacatecas. Half of the samples were subjected to the lixiviation process in a local metal recovery plant and the other part was analyzed without processing. The analysis of both types of samples by means of the PIXE was carried out in the University of Arizona in Tucson. (Author)

  9. CdTe detector based PIXE mapping of geological samples

    Energy Technology Data Exchange (ETDEWEB)

    Chaves, P.C., E-mail: cchaves@ctn.ist.utl.pt [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal); Taborda, A. [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal); Oliveira, D.P.S. de [Laboratório Nacional de Energia e Geologia (LNEG), Apartado 7586, 2611-901 Alfragide (Portugal); Reis, M.A. [Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); IST/ITN, Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear, EN10, 2686-953 Sacavém (Portugal)

    2014-01-01

    A sample collected from a borehole drilled approximately 10 km ESE of Bragança, Trás-os-Montes, was analysed by standard and high energy PIXE at both CTN (previous ITN) PIXE setups. The sample is a fine-grained metapyroxenite grading to coarse-grained in the base with disseminated sulphides and fine veinlets of pyrrhotite and pyrite. Matrix composition was obtained at the standard PIXE setup using a 1.25 MeV H{sup +} beam at three different spots. Medium and high Z elemental concentrations were then determined using the DT2fit and DT2simul codes (Reis et al., 2008, 2013 [1,2]), on the spectra obtained in the High Resolution and High Energy (HRHE)-PIXE setup (Chaves et al., 2013 [3]) by irradiation of the sample with a 3.8 MeV proton beam provided by the CTN 3 MV Tandetron accelerator. In this paper we present results, discuss detection limits of the method and the added value of the use of the CdTe detector in this context.

  10. Regional spent fuel storage facility (RSFSF)

    International Nuclear Information System (INIS)

    Dyck, H.P.

    1999-01-01

    The paper gives an overview of the meetings held on the technology and safety aspects of regional spent fuel storage facilities. The questions of technique, economy and key public and political issues will be covered as well as the aspects to be considered for implementation of a regional facility. (author)

  11. Combined PIXE and XPS analysis on republican and imperial Roman coins

    International Nuclear Information System (INIS)

    Dacca, A.; Prati, P.; Zucchiatti, A.; Lucarelli, F.; Mando, P.A.; Gemme, G.; Parodi, R.; Pera, R.

    2000-01-01

    A combined PIXE and XPS analysis has been performed on a few Roman coins of the republican and imperial age. The purpose was to investigate via XPS the nature and extent of patina in order to be capable of extracting PIXE data relative to the coins bulk. The inclusion of elements from the surface layer, altered by oxidation and inclusion, is a known source of uncertainty in PIXE analyses of coins, performed to assess the composition and the provenance

  12. Application of micro-PIXE and imaging technology to life science (Joint research)

    International Nuclear Information System (INIS)

    Satoh, Takahiro; Ishii, Keizo

    2011-03-01

    The joint research on 'Application of micro-PIXE and imaging technology to life science' supported by the Inter-organizational Atomic Energy Research Program, had been performed for three years, from 2006FY to 2009FY. Aiming to apply in-air micro-PIXE analytical system to life science, the research was consisting of 7 collaborative themes related to beam engineering for micro-PIXE and applied technology of element mapping in biological/medical fields. The system, so-called micro-PIXE camera, to acquire spatial element mapping in living cells was originally developed by collaborative research between the JAEA and the department of engineering of Tohoku University. This review covers these research results. (author)

  13. PIXE analyses of polished otoliths for identification of anadromous whitefish in the Baltic Sea

    International Nuclear Information System (INIS)

    Lill, Jan-Olof; Heimbrand, Yvette; Slotte, Joakim; Himberg, Mikael; Florin, Ann-Britt; Hägerstrand, Henry

    2015-01-01

    In this work we describe an application of particle-induced X-ray emission (PIXE) to the elemental analysis of polished otoliths of whitefish. Two spots on polished otoliths were irradiated; one spot in the core region of the otolith and another one close to the edge. The irradiations were performed in air with a collimated 0.5 mm proton beam. The ratio of the strontium concentrations in the two spots was used to distinguish between different ecotypes (river, sea, lake) of whitefish. Criteria on the ratios were suggested for identification of the whitefish forms. The results were compared to results of μ-beam PIXE scans as well as multi-point scans with the 0.5 mm proton beam. The measuring set-up and the results are discussed.

  14. PIXE analyses of polished otoliths for identification of anadromous whitefish in the Baltic Sea

    Energy Technology Data Exchange (ETDEWEB)

    Lill, Jan-Olof, E-mail: jlill@abo.fi [Accelerator Laboratory, Turku PET Centre, Åbo Akademi University, Turku (Finland); Heimbrand, Yvette [Institute of Coastal Research, Department of Aquatic Resources, Swedish University of Agricultural Sciences (Sweden); Slotte, Joakim [Physics, Faculty of Science and Engineering, Åbo Akademi University, Turku (Finland); Himberg, Mikael [Laboratory of Aquatic Pathobiology, Faculty of Science and Engineering, Åbo Akademi University, Turku (Finland); Florin, Ann-Britt [Institute of Coastal Research, Department of Aquatic Resources, Swedish University of Agricultural Sciences (Sweden); Hägerstrand, Henry [Laboratory of Aquatic Pathobiology, Faculty of Science and Engineering, Åbo Akademi University, Turku (Finland)

    2015-11-15

    In this work we describe an application of particle-induced X-ray emission (PIXE) to the elemental analysis of polished otoliths of whitefish. Two spots on polished otoliths were irradiated; one spot in the core region of the otolith and another one close to the edge. The irradiations were performed in air with a collimated 0.5 mm proton beam. The ratio of the strontium concentrations in the two spots was used to distinguish between different ecotypes (river, sea, lake) of whitefish. Criteria on the ratios were suggested for identification of the whitefish forms. The results were compared to results of μ-beam PIXE scans as well as multi-point scans with the 0.5 mm proton beam. The measuring set-up and the results are discussed.

  15. Micro-PIXE for the quantitative imaging of chemical elements in single cells

    International Nuclear Information System (INIS)

    Ortega, R.

    2013-01-01

    Full text: The knowledge of the intracellular distribution of biological relevant metals is important to understand their mechanisms of action in cells, either for physiological, toxicological or pathological processes. However, the direct detection of trace metals in single cells is a challenging task that requires sophisticated analytical developments. The aim of this seminar will be to present the recent achievements in this field using micro-PIXE analysis. The combination of micro-PIXE with RBS (Rutherford Backscattering Spectrometry) and STIM (Scanning Transmission lon Microscopy) allows the quantitative determination of trace metal content within sub-cellular compartments. The application of STlM analysis will be more specifically highlighted as it provides high spatial resolution imaging (<200 nm) and excellent mass sensitivity (<0.1 ng). Application of the STIM-PIXE-RBS methodology is absolutely needed when organic mass loss appears during PIXE-RBS irradiation. This combination of STIM-PIXE-RBS provides fully quantitative determination of trace element content, expressed in μg/g, which is a quite unique capability for micro-PIXE compared to other micro-analytical methods such as the electron and synchrotron X-ray fluorescence or the techniques based on mass spectrometry. Examples of micro-PIXE studies for subcellular imaging of trace elements in the various fields of interest will be presented such as metal-based toxicology, pharmacology, and neuro degeneration [1] R. Ortega, G. Devés, A. Carmona. J. R. Soc. Interface, 6, (2009) S649-S658. (author)

  16. GIT1/βPIX signaling proteins and PAK1 kinase regulate microtubule nucleation.

    Science.gov (United States)

    Černohorská, Markéta; Sulimenko, Vadym; Hájková, Zuzana; Sulimenko, Tetyana; Sládková, Vladimíra; Vinopal, Stanislav; Dráberová, Eduarda; Dráber, Pavel

    2016-06-01

    Microtubule nucleation from γ-tubulin complexes, located at the centrosome, is an essential step in the formation of the microtubule cytoskeleton. However, the signaling mechanisms that regulate microtubule nucleation in interphase cells are largely unknown. In this study, we report that γ-tubulin is in complexes containing G protein-coupled receptor kinase-interacting protein 1 (GIT1), p21-activated kinase interacting exchange factor (βPIX), and p21 protein (Cdc42/Rac)-activated kinase 1 (PAK1) in various cell lines. Immunofluorescence microscopy revealed association of GIT1, βPIX and activated PAK1 with centrosomes. Microtubule regrowth experiments showed that depletion of βPIX stimulated microtubule nucleation, while depletion of GIT1 or PAK1 resulted in decreased nucleation in the interphase cells. These data were confirmed for GIT1 and βPIX by phenotypic rescue experiments, and counting of new microtubules emanating from centrosomes during the microtubule regrowth. The importance of PAK1 for microtubule nucleation was corroborated by the inhibition of its kinase activity with IPA-3 inhibitor. GIT1 with PAK1 thus represent positive regulators, and βPIX is a negative regulator of microtubule nucleation from the interphase centrosomes. The regulatory roles of GIT1, βPIX and PAK1 in microtubule nucleation correlated with recruitment of γ-tubulin to the centrosome. Furthermore, in vitro kinase assays showed that GIT1 and βPIX, but not γ-tubulin, serve as substrates for PAK1. Finally, direct interaction of γ-tubulin with the C-terminal domain of βPIX and the N-terminal domain of GIT1, which targets this protein to the centrosome, was determined by pull-down experiments. We propose that GIT1/βPIX signaling proteins with PAK1 kinase represent a novel regulatory mechanism of microtubule nucleation in interphase cells. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Particulate characterization by PIXE multivariate spectral analysis

    International Nuclear Information System (INIS)

    Antolak, Arlyn J.; Morse, Daniel H.; Grant, Patrick G.; Kotula, Paul G.; Doyle, Barney L.; Richardson, Charles B.

    2007-01-01

    Obtaining particulate compositional maps from scanned PIXE (proton-induced X-ray emission) measurements is extremely difficult due to the complexity of analyzing spectroscopic data collected with low signal-to-noise at each scan point (pixel). Multivariate spectral analysis has the potential to analyze such data sets by reducing the PIXE data to a limited number of physically realizable and easily interpretable components (that include both spectral and image information). We have adapted the AXSIA (automated expert spectral image analysis) program, originally developed by Sandia National Laboratories to quantify electron-excited X-ray spectroscopy data, for this purpose. Samples consisting of particulates with known compositions and sizes were loaded onto Mylar and paper filter substrates and analyzed by scanned micro-PIXE. The data sets were processed by AXSIA and the associated principal component spectral data were quantified by converting the weighting images into concentration maps. The results indicate automated, nonbiased, multivariate statistical analysis is useful for converting very large amounts of data into a smaller, more manageable number of compositional components needed for locating individual particles-of-interest on large area collection media

  18. PIXE identification of the provenance of ferruginous rocks used by Neanderthals

    International Nuclear Information System (INIS)

    Mathis, François; Bodu, Pierre; Dubreuil, Olivier; Salomon, Hélène

    2014-01-01

    Les Bossats, near Ormesson, France, is a newly discovered late Mousterian open air site dated to around 47,000 years ago by thermoluminescence. The archaeological level, fossilized by loess, revealed a rich industry based on the discoid mode, associated with numerous fragments of red and yellow iron oxide-rich rocks showing clear traces of powder production (abrasion, striation, scraping), which are exceptional remains for this remote period. Archeological material and geological samples from the close environment were studied by PIXE and by petrographical observations made on thin sections. The geological sources were identified by means of PIXE analyses on two IBA facilities: AGLAE (2 MV tandem) at the C2RMF in Paris and the cyclotron of the IPNAS (University of Liège). We paid particular attention to the comparison of results obtained on both installations by using the same set of geological standards and by a fine evaluation of the limit of detection relative to each trace elements of interest for both experimental set ups. The elemental fingerprint of one geological source of iron-rich concretions corresponds clearly with the archaeological collection. At least, this investigation demonstrates that the colouring materials were minutely selected in the close neighbouring of the site by the Neanderthals

  19. Elemental analysis with external-beam PIXE

    Science.gov (United States)

    Lin, E. K.; Wang, C. W.; Teng, P. K.; Huang, Y. M.; Chen, C. Y.

    1992-05-01

    A beamline system and experimental setup has been established for elemental analysis using PIXE with an external beam. Experiments for the study of the elemental composition of ancient Chinese potsherds (the Min and Ching ages) were performed. Continuum X-ray spectra from the samples bombarded by 3 MeV protons have been measured with a Si(Li) detector. From the analysis of PIXE data, the concentration of the main elements (Al, Si, K, and Ca) and of more than ten trace elements in the matrices and glazed surfaces were determined. Results for two different potsherds are presented, and those obtained from the glaze colorants are compared with the results of measurements on a Ching blue-and-white porcelain vase.

  20. Determination of Hg concentration in gases by PIXE

    Science.gov (United States)

    Dutkiewicz, E.; van Kuijen, W. J. P.; Munnik, F.; Mutsaers, P. H. A.; Rokita, E.; de Voigt, M. J. A.

    1992-05-01

    A method for determination of the concentration of mercury in the gaseous phase is described. In the first step of the method a stable sulphur-mercury complex is formed. For this purpose sulphur is deposited on a filter and the investigated gas flows through the filter. Millipore filters and the deposition of sulphur from Na2S2O3 * 5H2O solution were found to be most suitable. The amount of Hg absorbed on the filter was determined by PIXE or by NAA in the second step of the method. An optimization of proton energy was performed in the PIXE analysis to obtain the maximal signal-to-background ratio. The detection limit of the method, expressed as the minimal amount of Hg which has to flow through the filter equals to 30 and 2 ng for PIXE and NAA techniques, respectively. Applications of the method are also described.

  1. The potential of PIXE analytical work in water pollution

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, H.; Takahashi, Y.; Ishii, K. [Dept. of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Miyagi (JP)] [and others

    1999-07-01

    A method has been developed and tested for PIXE analysis of soluble and insoluble constituents in a variety of water samples in our surroundings. Insoluble components were filtered on a Nuclepore filter of 0.4-{mu}m pores. For soluble fractions, a target of major components was made from a 0.15-ml filtrate evaporated on a user-made polycarbonate film, and in turn heavy metals in trace amounts were preconcentrated in a PIXE-target through the use of a combination of dibenzyldithiocarbamate-chelation with subsequent condensation into dibenzylidene-D-sorbitol gels. These three kinds of targets were analyzed with a PIXE system of 3-MeV proton beams. The widespread concentrations (several tenths of ppb to a few tens of ppm) of {approx}24 elements from Na to Pb were determined simultaneously in a precision sufficient to reveal the elemental distribution between the soluble and insoluble fractions of various aqueous sample such as river water, rain water and water leaking from disposal sites of industrial wastes. Hence, the methodology for preparing three types of targets promotes the PIXE analysis to a truly effective means for monitoring a water-pollution problem in our surroundings. (author)

  2. The potential of PIXE analytical work in water pollution

    International Nuclear Information System (INIS)

    Yamazaki, H.; Takahashi, Y.; Ishii, K.

    1999-01-01

    A method has been developed and tested for PIXE analysis of soluble and insoluble constituents in a variety of water samples in our surroundings. Insoluble components were filtered on a Nuclepore filter of 0.4-μm pores. For soluble fractions, a target of major components was made from a 0.15-ml filtrate evaporated on a user-made polycarbonate film, and in turn heavy metals in trace amounts were preconcentrated in a PIXE-target through the use of a combination of dibenzyldithiocarbamate-chelation with subsequent condensation into dibenzylidene-D-sorbitol gels. These three kinds of targets were analyzed with a PIXE system of 3-MeV proton beams. The widespread concentrations (several tenths of ppb to a few tens of ppm) of ∼24 elements from Na to Pb were determined simultaneously in a precision sufficient to reveal the elemental distribution between the soluble and insoluble fractions of various aqueous sample such as river water, rain water and water leaking from disposal sites of industrial wastes. Hence, the methodology for preparing three types of targets promotes the PIXE analysis to a truly effective means for monitoring a water-pollution problem in our surroundings. (author)

  3. PIXE analysis of otoliths from several species of teleost fish

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Sakamoto, Wataru; Maeda, Kuniko.

    1994-01-01

    In-air PIXE was used to analyze trace elements in otoliths from several species of teleost fish in order to examine the correlation between the trace elements concentrations and environmental conditions. Mn, Fe, Zn and Sr were detected accurately in the order of ppm by using the in-air PIXE. It seemed that concentrations of Sr and Zn in red sea bream otoliths increased in proportion to higher seawater temperature. In addition, there were significant differences in trace element composition between that of reared red sea bream and rockfish and that of wild ones. Preliminary results indicate that the PIXE is a powerful technique to investigate fish otoliths. (author)

  4. Atmospheric environment measurement 3. Environmental pollution monitoring system using PIXE analysis

    International Nuclear Information System (INIS)

    Ishii, Keizo

    2009-01-01

    The PIXE(Proton Induced X-ray Emission) method is used in various fields owing to its high sensitivity. This method can be used to analyze multiple elements in a short time and therefore is suitable for the analysis of large quantities of environmental samples. We researched the effect of removing footwear in a room on indoor aerosol pollution. The concentration of aerosol particles in the case that footwear was not removed was 5 times larger than in the case when footwear was removed. We were able to identify a source of air pollution using both the results of PIXE analysis and information on wind direction. We applied PIXE analysis to investigate airborne yellow sand, which originals from the Gobi desert. By analyzing each yellow sand particle, hazardous yellow sand could be detected. We also applied PIXE analysis to river water pollution. River water samples were collected at a number of points along a river. The dilution of metallic elements by the river water was observed. Thus, it was shown that monitoring systems using the PIXE method are very useful for monitoring environmental pollution. (author)

  5. Exploring advantages of 4He-PIXE analysis for layered objects in cultural heritage

    International Nuclear Information System (INIS)

    Roehrs, S.; Calligaro, T.; Mathis, F.; Ortega-Feliu, I.; Salomon, J.; Walter, P.

    2006-01-01

    In the field of cultural heritage 4 He particle beams are often used to perform RBS analysis. In most cases the simultaneously produced X-rays are not considered for PIXE analysis. This paper aims to explore the potentials of 4 He induced X-ray emission (α-PIXE) using 4, 5 and 6 MeV 4 He beams and to compare its performance with that of conventional PIXE with 3 MeV protons. The α-PIXE and α-RBS spectra were collected at the same time in a vacuum chamber. The X-ray yields produced by 6 MeV 4 He beam for K-lines were found to be superior to those of protons for atomic numbers below 25. An additional advantage of α-PIXE is the lower bremsstrahlung background which leads to an improved peak to noise ratio for certain elements

  6. Trace elements in aero transported solid particles in urban and rural atmosphere using PIXE

    International Nuclear Information System (INIS)

    Salazar Matarrita, A.

    1997-01-01

    For the present study, multi schedule collectors (type Streaker) were located, in four places selected by their relative location, to possible fountains of identifiable s particles. The cooperation among the Nuclear Laboratory PIXE of the State University of Florida, U.S.A. Permitted the irradiation of the collected samples, using the facilities of the Accelerator Van der Graaff of 4 MeV. The x-rays spectra emission,were valued in the Laboratory LAFNA and the Laboratory PIXE, using the Hex computational code. They were determined among 12 and 15 chemical elements to level of plans, quantity that depends on the place of recollection. The statistical analysis of the data recollected, was carried out applying a nalysis of factors . This statistical program of analysis, permits the regroup of the elements, depending on the systematic variation of the concentrations. A graphic analysis of distribution was carried out, besides, schedule of the hours of I continuous monitoring. This permits to observe its own singularities. Giving the opportunity to determine, possible fountains of origin of the collected particles. (author) [es

  7. Examination of quantitative accuracy of PIXE analysis for atmospheric aerosol particle samples. PIXE analysis of NIST air particulate on filter media

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Sera, Koichiro

    2005-01-01

    In order to confirm accuracy of the direct analysis of filter samples containing atmospheric aerosol particles collected on a polycarbonate membrane filter by PIXE, we carried out PIXE analysis on a National Institute of Standards and Technology (NIST, USA) air particulate on filter media (SRM 2783). For 16 elements with NIST certified values determined by PIXE analysis - Na, Mg, Al, Si, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb - quantitative values were 80-110% relative to NIST certified values except for Na, Al, Si and Ni. Quantitative values of Na, Al and Si were 140-170% relative to NIST certified values, which were all high, and Ni was 64%. One possible reason why the quantitative values of Na, Al and Si were higher than the NIST certified values could be the difference in the X-ray spectrum analysis method used. (author)

  8. Application of PIXE analysis to study urban atmospheric aerosols from downtown Havana City

    International Nuclear Information System (INIS)

    Perez Zayas, Grizel; Pinnera Hernandez, Ibrahin; Ramos Aruca, Maridelin; Guibert Gala, Rolando; Molina Esquivel, Enrique; Martinez Varona, Miriam; Fernandez Arocha, Ariadna; Aldape Ugalde, Francisca; Flores Maldonado, Javier

    2010-01-01

    The present work reports, the results of a first study of elemental composition in airborne particulate matter (in fine and coarse particle size fractions) collected at the Atmospheric Monitoring Station in the Municipality of Centro Habana, using the Particle-Induced X-ray Emission (PIXE) technique. At present, there is not information available about elements contents in airborne particulate matter from this region. For this study, we carried out a sampling campaign during five months (November 14, 2006 to April 19, 2007). The samples were collected every second day during 24 h under an air flux of 20 l/min. The air sampler used was a Gent Sampler equipped with a Stacked Filter Unit (SFU) system which allows the aerosol collection in both size fractions simultaneously. A total of 144 aerosol samples were collected (72 correspond to the fine mass particle and 72 to the coarse mass particle). For PIXE analysis, the samples were irradiated by 2.5 MeV energy protons from the 2MV Van de Graff Tandetron Accelerator from the Laboratory of PIXE analysis at ININ, Mexico. A total of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were consistently detected in both particle size fractions with minimum detection limits in the range of 1-10 ng/m3. The quantitative results obtained from PIXE elemental analysis for mass of particles in both fractions have revealed important information that has been used in a first attempt to understand and to characterize the atmospheric pollution of this area. A general discussion about these results is presented in this paper. (author)

  9. Application of PIXE analysis to study urban atmospheric aerosols from downtown Havana City

    International Nuclear Information System (INIS)

    Perez Zayas, Grizel; Pinnera Hernandez, Ibrahin; Ramos Aruca, Maridelin; Guibert Gala, Rolando; Molina Esquivel, Enrique; Martinez Varona, Miriam; Fernandez Arocha, Ariadna; Aldape Ugalde, Francisca; Flores Maldonado, Javier

    2009-01-01

    The present work reports, the results of a first study of elemental composition in airborne particulate matter (in fine and coarse particle size fractions) collected at the Atmospheric Monitoring Station in the Municipality of Centro Habana, using the Particle-Induced X-ray Emission (PIXE) technique. At present, there is not information available about elements contents in airborne particulate matter from this region. For this study, we carried out a sampling campaign during five months (November 14, 2006 to April 19, 2007). The samples were collected every second day during 24 h under an air flux of 20 l/min. The air sampler used was a Gent Sampler equipped with a Stacked Filter Unit (SFU) system which allows the aerosol collection in both size fractions simultaneously. A total of 144 aerosol samples were collected (72 correspond to the fine mass particle and 72 to the coarse mass particle). For PIXE analysis, the samples were irradiated by 2.5 MeV energy protons from the 2MV Van de Graff Tandetron Accelerator from the Laboratory of PIXE analysis at ININ, Mexico. A total of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were consistently detected in both particle size fractions with minimum detection limits in the range of 1-10 ng/m3. The quantitative results obtained from PIXE elemental analysis for mass of particles in both fractions have revealed important information that has been used in a first attempt to understand and to characterize the atmospheric pollution of this area. A general discussion about these results is presented in this paper. (author)

  10. Studies of prehistoric flint tools by PIXE

    International Nuclear Information System (INIS)

    Smit, Z.

    2002-01-01

    The trace elements preserved on sharp edges of stone tools may provide some information about the worked material, which in turn may serve for the reconstruction of users way of life. Since the amount of the deposited worked material is minute, it can only be detected by sensitive fluorescence techniques, induced by electrons in the electron microscopes, or by light ions from the particle accelerators (PIXE). The trace element deposition was studied by PIXE for a set of experimental tools used for working bone and wood, and for a set of archaeological artefacts dating from the late paleolithic till neolithic period. (author)

  11. PIXE technique use for urban aerosol characterization

    International Nuclear Information System (INIS)

    Dias da Cunha, K.; Lazarra, M.; Nazare, R.A.; D'Oliveira, D.; Barros Leite, C.V.

    1996-01-01

    A cascade impactor and PIXE technique were used to estimate the air pollution in a urban area. PIXE is a multielementar method and for all elements the detection limit is about nanograms. The particle size distribution was determined using a cascade impactor with six stage. It collects the particles in the respirable and invaluable of aerosol. The samples were collected close to Planetary in Rio de Janeiro City. The results indicate that particles containing Cu, Zn, Ni, Fe, Mn, Cr, V, Ti, Ca and K. The particle was in the respirable fraction of with MMAD,2 μm. (author)

  12. Obsidian provenance studies in archaeology: A comparison between PIXE, ICP-AES and ICP-MS

    International Nuclear Information System (INIS)

    Bellot-Gurlet, Ludovic; Poupeau, Gerard; Salomon, Joseph; Calligaro, Thomas; Moignard, Brice; Dran, Jean-Claude; Barrat, Jean-Alix; Pichon, Laurent

    2005-01-01

    Elemental composition fingerprinting by PIXE technique is very attractive for obsidian provenance studies as it may proceed in a non-destructive mode, even if a more complete elemental characterization can be obtained by ICP-MS and/or ICP-AES. Only few studies have compared results obtained by both methods for solid rock samples. In this work, elemental compositions were determined by ICP-MS/-AES for international geochemical standards and by ICP-MS/-AES and PIXE for inter-laboratory reference obsidians. In addition 49 obsidian source samples and artefacts were analysed by both ICP-MS/-AES and PIXE. Instrumental work and measurement quality control performed for obsidian chemical characterization, underline that PIXE and ICP-MS/-AES provide reproducible, accurate and comparable measurements. In some volcanic districts the limited number of elements dosed by PIXE is sufficient for the discrimination of the potential raw sources of obsidians. Therefore, PIXE can be an advantageous substitute to ICP-MS/-AES techniques for provenance studies

  13. αPIX Is a Trafficking Regulator that Balances Recycling and Degradation of the Epidermal Growth Factor Receptor.

    Directory of Open Access Journals (Sweden)

    Fanny Kortüm

    Full Text Available Endosomal sorting is an essential control mechanism for signaling through the epidermal growth factor receptor (EGFR. We report here that the guanine nucleotide exchange factor αPIX, which modulates the activity of Rho-GTPases, is a potent bimodal regulator of EGFR trafficking. αPIX interacts with the E3 ubiquitin ligase c-Cbl, an enzyme that attaches ubiquitin to EGFR, thereby labelling this tyrosine kinase receptor for lysosomal degradation. We show that EGF stimulation induces αPIX::c-Cbl complex formation. Simultaneously, αPIX and c-Cbl protein levels decrease, which depends on both αPIX binding to c-Cbl and c-Cbl ubiquitin ligase activity. Through interaction αPIX sequesters c-Cbl from EGFR and this results in reduced EGFR ubiquitination and decreased EGFR degradation upon EGF treatment. However, quantitatively more decisive for cellular EGFR distribution than impaired EGFR degradation is a strong stimulating effect of αPIX on EGFR recycling to the cell surface. This function depends on the GIT binding domain of αPIX but not on interaction with c-Cbl or αPIX exchange activity. In summary, our data demonstrate a previously unappreciated function of αPIX as a strong promoter of EGFR recycling. We suggest that the novel recycling regulator αPIX and the degradation factor c-Cbl closely cooperate in the regulation of EGFR trafficking: uncomplexed αPIX and c-Cbl mediate a positive and a negative feedback on EGFR signaling, respectively; αPIX::c-Cbl complex formation, however, results in mutual inhibition, which may reflect a stable condition in the homeostasis of EGF-induced signal flow.

  14. GridPix detectors: Production and beam test results

    International Nuclear Information System (INIS)

    Koppert, W.J.C.; Bakel, N. van; Bilevych, Y.; Colas, P.; Desch, K.; Fransen, M.; Graaf, H. van der; Hartjes, F.; Hessey, N.P.; Kaminski, J.; Schmitz, J.; Schön, R.; Zappon, F.

    2013-01-01

    The innovative GridPix detector is a Time Projection Chamber (TPC) that is read out with a Timepix-1 pixel chip. By using wafer post-processing techniques an aluminium grid is placed on top of the chip. When operated, the electric field between the grid and the chip is sufficient to create electron induced avalanches which are detected by the pixels. The time-to-digital converter (TDC) records the drift time enabling the reconstruction of high precision 3D track segments. Recently GridPixes were produced on full wafer scale, to meet the demand for more reliable and cheaper devices in large quantities. In a recent beam test the contribution of both diffusion and time walk to the spatial and angular resolutions of a GridPix detector with a 1.2 mm drift gap are studied in detail. In addition long term tests show that in a significant fraction of the chips the protection layer successfully quenches discharges, preventing harm to the chip

  15. GridPix detectors: Production and beam test results

    Science.gov (United States)

    Koppert, W. J. C.; van Bakel, N.; Bilevych, Y.; Colas, P.; Desch, K.; Fransen, M.; van der Graaf, H.; Hartjes, F.; Hessey, N. P.; Kaminski, J.; Schmitz, J.; Schön, R.; Zappon, F.

    2013-12-01

    The innovative GridPix detector is a Time Projection Chamber (TPC) that is read out with a Timepix-1 pixel chip. By using wafer post-processing techniques an aluminium grid is placed on top of the chip. When operated, the electric field between the grid and the chip is sufficient to create electron induced avalanches which are detected by the pixels. The time-to-digital converter (TDC) records the drift time enabling the reconstruction of high precision 3D track segments. Recently GridPixes were produced on full wafer scale, to meet the demand for more reliable and cheaper devices in large quantities. In a recent beam test the contribution of both diffusion and time walk to the spatial and angular resolutions of a GridPix detector with a 1.2 mm drift gap are studied in detail. In addition long term tests show that in a significant fraction of the chips the protection layer successfully quenches discharges, preventing harm to the chip.

  16. Forensic analysis of tempered sheet glass by particle induced X-ray emission (PIXE)

    Energy Technology Data Exchange (ETDEWEB)

    Jisonna, L.J. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); DeYoung, P.A., E-mail: deyoung@hope.ed [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Ferens, J.; Hall, C.; Lunderberg, J.M.; Mears, P. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Padilla, D. [Department of Physics, San Diego State University, San Diego, CA 92182-1233 (United States); Peaslee, G.F. [Department of Chemistry and Department of Physics, Hope College, Holland, MI 49422-9000 (United States); Sampson, R. [Department of Physics, Columbia University, New York, NY 10027 (United States)

    2011-05-15

    Highlights: {yields} PIXE was found to give the same results for trace elements in glass as ICP. {yields} PIXE can non-destructively determine trace element concentrations in auto glass. {yields} Measured Ca, Fe, Ti, Mn, and Sr in auto glass with PIXE. -- Abstract: The elemental concentrations of five trace elements in tempered sheet glass fragments were determined using particle-induced X-ray emission (PIXE) spectrometry. The trace element concentrations for calcium, iron, manganese, strontium, and titanium are compared to those obtained by inductively-coupled plasma-atomic emission spectrometry (ICP-AES) following complete digestion by hydrofluoric acid. For these five elements, the absolute concentrations obtained by both methods are shown to agree well over a wide range of concentrations. The limits of detection for trace elements are typically lower for the ICP-AES method. However, we show that the concentrations of these five elements can be accurately measured by the PIXE method. Since PIXE is an entirely non-destructive method, there exists a niche for this technique to be used as a complement to the more sensitive ICP-AES technique in the forensic analysis of sheet glass.

  17. Qualitative PIXE analysis of mineral elements in some dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Gugiu, M.; Moldovan, Maria

    2002-01-01

    Dental composites, made by particles of glass, ceramics and quartz embedded in an organic polymer, develop at a high rate. However, commercial composites are expensive and recently the 'Restacril' biomaterials company became prepared to offer a low-cost alternative. The durability of dental fillings depends not only on biomaterial's gross chemical composition, but also on impurities. These may influence the chemical, mechanical and surface properties of the inorganic particles and modify the composites' clinical behavior. Thus elemental analysis is necessary to improve the biomaterials' quality. Nuclear and atomic methods allow sensitive multielement detection, and we previously analyzed some commercial composites by particle-induced X-ray emission (PIXE). Here we applied PIXE in the qualitative analysis of six new Romanian biomaterials, aiming to compare their nominal and detected composition and paying attention to the impurities. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normal to the beam and connected to a multichannel analyzer and to a computer. Solid samples of composites with a flat surface were fixed at 45 angle, absorber foil of Al 30 mm thick was used, and integration of beam current was done. In all composites PIXE detected mineral elements with Z > 19 down to trace levels. All major nominal elements with Z > 20 - Ca, Sr, Zr, Ba, and Yb - were detected by PIXE. In addition, many minor and trace elements absent from the nominal formulations were seen, including K, Ti, Mn, Fe, Ni, Cu, Zn, Ga, Ag, Cd, Hf, and As/Pb. Such impurities may come from rough materials and preparative technologies. The impurities in Romanian composites are comparable to those in some commercial biomaterials but higher than in other ones. Thus PIXE analysis of mineral elements in Romanian composites, even qualitative, appears useful for quality control and improvement. (authors)

  18. Obisdian sourcing by PIXE analysis at AURA2

    International Nuclear Information System (INIS)

    Neve, S.R.; Barker, P.H.; Holroyd, S.; Sheppard, P.J.

    1994-01-01

    The technique of Proton Induced X-ray Emission is a suitable method for the elemental analysis of obsidian samples and artefacts. By comparing the elemental composition of obsidian artefacts with those of known sources of obsidian and identifying similarities, the likely origin of the sample can be discovered and information about resource procurement gained. A PIXE facility has now been established at the Auckland University Research Accelerator Laboratory, AURA2. It offers a rapid, multi-element, non-destructive method of characterisation of obsidian samples ranging from small chips to large pieces. In an extensive survey of Mayor Island obsidian, a discrimination has been made between the different locations of obsidian deposits on the island. In addition, using the database developed at AURA2, artefacts from the site of Opita, Hauraki Plains, have been sourced. (Author). 18 refs., 8 figs., 7 tabs., 1 appendix

  19. Analysis of kidney stones by PIXE and RBS techniques

    Energy Technology Data Exchange (ETDEWEB)

    Alkofai, M M [Physics Dept., Yarmouk University, Irbid, (Jordan); Hallak, A B [Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, (Saudi Arabia)

    1995-10-01

    Human kidney stones were analyzed by PIXE and RBS techniques using 2 MeV He{sup ++} beam. The stones were found to contain the elements: C, N, O, F, Na, Mg, Si, P, S, Cl, K, Ca, Fe and Br. Results obtained by PIXE agree with the results obtained by RBS within experimental errors. A Mechanism for the formation of the kidney stones is suggested. 3 figs., 1 tab.

  20. Analysis of kidney stones by PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Alkofai, M.M.; Hallak, A.B.

    1995-01-01

    Human kidney stones were analyzed by PIXE and RBS techniques using 2 MeV He ++ beam. The stones were found to contain the elements: C, N, O, F, Na, Mg, Si, P, S, Cl, K, Ca, Fe and Br. Results obtained by PIXE agree with the results obtained by RBS within experimental errors. A Mechanism for the formation of the kidney stones is suggested. 3 figs., 1 tab

  1. Theoretical detection limit of PIXE analysis using 20 MeV proton beams

    Science.gov (United States)

    Ishii, Keizo; Hitomi, Keitaro

    2018-02-01

    Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.

  2. PIXE analysis of Zn enzymes

    International Nuclear Information System (INIS)

    Solis, C.; Oliver, A.; Andrade, E.; Ruvalcaba-Sil, J.L.; Romero, I.; Celis, H.

    1999-01-01

    Zinc is a necessary component in the action and structural stability of many enzymes. Some of them are well characterized, but in others, Zn stoichiometry and its association is not known. PIXE has been proven to be a suitable technique for analyzing metallic proteins embedded in electrophoresis gels. In this study, PIXE has been used to investigate the Zn content of enzymes that are known to carry Zn atoms. These include the carbonic anhydrase, an enzyme well characterized by other methods and the cytoplasmic pyrophosphatase of Rhodospirillum rubrum that is known to require Zn to be stable but not how many metal ions are involved or how they are bound to the enzyme. Native proteins have been purified by polyacrylamide gel electrophoresis and direct identification and quantification of Zn in the gel bands was performed with an external proton beam of 3.7 MeV energy

  3. Proton-induced X-ray emission (PIXE) spectrometry - state of the art

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1986-01-01

    The development of the PIXE method for multielemental analysis is described. A brief account is given of the physical principles and the experimental arrangements. The use of PIXE is illustrated by a number of typical applications in geology, biology, medicine and environmental research. (orig.) [de

  4. System of pattern analysis of PIXE spectra

    Energy Technology Data Exchange (ETDEWEB)

    Murozono, K; Iwasaki, S; Inoue, J; Ishii, K; Kitamura, M [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sera, K; Futatsugawa, S

    1996-07-01

    We have developed an analysis system based on the pattern analysis method. By testing the system, several difficulties of the present method have been identified. We found the following solutions for them: pre-selection of candidate elements in a sample and the use of a proper absorber. The pre-selection of the candidate elements will not be a serious drawback in the industrial PIXE, because it will be easy to pre-process the spectra for a few samples in the beginning of the mass processing of samples of the same kind. On the other hand, reduction of the efficiency due to the use of funny filter is significant only in the lower energy region, where we usually do not suffer from insufficient yields of lighter elements in common samples. The selection of the most suitable filter requires PIXE user to be deeply experienced. In particular, it is not easy to choose the best filter to suppress the yield of peak of an abundant element as the absorption edge filter. It will be important task to find a set of suitable combination of representative samples and corresponding filters. Furthermore, the peak profile model should be improved from the simple Gaussian approximation to more realistic ones with exponential tail, flat component below the peak and escape peaks, etc. It is also necessary to develop a theoretical approach for the background shape of the bremsstrahlung. (J.P.N.)

  5. ePix: a class of architectures for second generation LCLS cameras

    International Nuclear Information System (INIS)

    Dragone, A; Caragiulo, P; Markovic, B; Herbst, R; Reese, B; Herrmann, S C; Hart, P A; Segal, J; Carini, G A; Kenney, C J; Haller, G

    2014-01-01

    ePix is a novel class of ASIC architectures, based on a common platform, optimized to build modular scalable detectors for LCLS. The platform architecture is composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog-to-digital converters per column. It also implements a dedicated control interface and all the required support electronics to perform configuration, calibration and readout of the matrix. Based on this platform a class of front-end ASICs and several camera modules, meeting different requirements, can be developed by designing specific pixel architectures. This approach reduces development time and expands the possibility of integration of detector modules with different size, shape or functionality in the same camera. The ePix platform is currently under development together with the first two integrating pixel architectures: ePix100 dedicated to ultra low noise applications and ePix10k for high dynamic range applications.

  6. Fish otoliths analysis by PIXE: application to stock discrimination

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Takai, Noriyuki; Sakamoto, Wataru; Yoshida, Koji; Maeda, Kuniko.

    1996-01-01

    Fish otoliths are continuously deposited from fish birth to its death along with encoding environmental information. In order to decode the information, PIXE was adopted as trace elemental analysis of the otoliths. Strontium to calcium concentration ratios of red sea bream otoliths varied among rearing stations. The Sr/Ca ratios of Lake Biwa catfishes also varied between male and female and among fishing grounds. The PIXE analysis was applied to the fish stock discrimination. (author)

  7. Radiation damage of paper samples in in-air PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T.; Orihara, H.

    1999-01-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  8. Radiation damage of paper samples in in-air PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, S.; Endo, H.; Ishii, K.; Yamazaki, H.; Tokai, Y.; Sugimoto, A.; Yamamoto, K.; Satoh, T. [Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Miyagi (Japan); Orihara, H. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center

    1999-07-01

    Degradation of paper caused by beam irradiation was investigated from a viewpoint of discoloration in PIXE analysis and its application to the paper samples of archaeology. Two types of paper (Japanese paper and fine quality paper) were tested in in-air PIXE analysis with 3 MeV protons. The degree of discoloration was quantitatively measured by the use of a colorimeter. The degree of discoloration was different for each tested paper and corresponded to the radiation dose of ions. It is resulted that even the in-air PIXE analysis should be carefully applied to archaeological treasures. Because discoloration of all tested paper decreased gradually at first but then increased after a few weeks. However, this phenomenon can be used to develop a technique of funny coloration. (author)

  9. TXRF, PIXE, SYXRF; principles, critical comparison and applications

    International Nuclear Information System (INIS)

    Knoechel, A.

    1990-01-01

    At first glance X-Ray fluorescence analysis seems to be a very sensitive and effectful method to detect element traces in the multielement mode. But in praxi the application range is restricted, if X-Ray tubes are used as excitation sources. To overcome this situation, it is necessary to improve the conditions of excitation and to reduce the background, produced by different scattering effects. TXRF, PIXE and SYXRF, which allow multielement analysis in the trace- and ultratrace region are using this strategy. In the case of TXRF a remarkable background reduction is achieved if the sample is prepared as a thin amorphous film on a planar sample holder and the excitation beam of a X-Ray tube is totally reflected on its surface. In the case of PIXE a particle beam of high intensity is used as excitation source, improving the conditions of excitation and giving the opportunity of spatial resolved analyses. In the case of SYXRF the X-Ray fraction of synchrotron radiation is used as excitation source, giving the opportunity, to improve the conditions of excitation as well as to reduce the background by using the high polarisation of the beam. In this case, too, spatial resolved analysis are possible. The principles of the three methods are described, their advantages and disadvantages are critically compared and advanced applications from different analytical fields are presented. (orig.)

  10. Determination of some heavy metals in wetlands by PIXE

    International Nuclear Information System (INIS)

    Ramirez O, J.; Rios M, C.

    2008-01-01

    In this work the results of the analysis are presented, using the PIXE technique (Proton Induced X-ray Emission), in soil samples of the El Bordo, Vetagrande, Zacatecas, before and after subjecting them to a lixiviation process for the recovering of gold, silver and mercury. This community is part of the mining region nearer to the Zacatecas city municipality, region in which the mining exploitation dates from the colonial time. During almost 350 years the 'yard benefit' method was used or amalgamation with mercury, process that besides having used big quantities of mercury, generated a great quantity of mineral waste calls 'mine wetlands', those that were accumulating, crawled by the rains, toward the streams that end in the prey 'The Pedernalillo'. The dispersion of wetlands them it has extended from the prey until the communities of Tacoaleche, Zoquite, Lampotal and El Bordo, embracing an approximate area of 16 x 2 Km 2 and forming with the course of the time an accumulated of several millions of tons. In order to determining if the process of recovery of gold, silver and mercury make soluble to other contained metals in these wastes, samples were gathered in an area of 600 m 2 in the community of The Border, Vetagrande, Zacatecas. Half of the samples were subjected to the lixiviation process in a local metal recovery plant and the other part was analyzed without processing. The analysis of both types of samples by means of the PIXE was carried out in the University of Arizona in Tucson. (Author)

  11. Quantitative elemental imaging of octopus stylets using PIXE and the nuclear microprobe

    International Nuclear Information System (INIS)

    Doubleday, Zoe; Belton, David; Pecl, Gretta; Semmens, Jayson

    2008-01-01

    By utilising targeted microprobe technology, the analysis of elements incorporated within the hard bio-mineralised structures of marine organisms has provided unique insights into the population biology of many species. As hard structures grow, elements from surrounding waters are incorporated effectively providing a natural 'tag' that is often unique to the animal's particular location or habitat. The spatial distribution of elements within octopus stylets was investigated, using the nuclear microprobe, to assess their potential for determining dispersal and population structure in octopus populations. Proton Induced X-ray Emission (PIXE) was conducted using the Dynamic Analysis method and GeoPIXE software package, which produced high resolution, quantitative elemental maps of whole stylet cross-sections. Ten elements were detected within the stylets which were heterogeneously distributed throughout the microstructure. Although Ca decreased towards the section edge, this trend was consistent between individuals and remained homogeneous in the inner region of the stylet, and thus appears a suitable internal standard for future microprobe analyses. Additional analyses used to investigate the general composition of the stylet structure suggested that they are amorphous and largely organic, however, there was some evidence of phosphatic mineralisation. In conclusion, this study indicates that stylets are suitable for targeted elemental analysis, although this is currently limited to the inner hatch region of the microstructure

  12. In-air micro-pixe analysis of tissue samples

    International Nuclear Information System (INIS)

    Tanaka, A.; Ishii, K.; Komori, Y.

    2002-01-01

    Micro-PIXE is capable of providing spatial distributions of elements in the micro-meter scale and its application to biology is useful to elucidate the cellular metabolism. Since, in this method, a sample target is usually irradiated with proton or α-particle beams in vacuum, beam heating results in evaporation of volatile elements an shrinking of the sample. In order to avoid these side effects, we previously developed a technique of in-air micro-PIXE analysis for samples of cultured cells. In addition to these, analysis of exposed tissue samples from living subjects is highly desirable in biological and medical research. Here, we describe a technique of in-air micro-PIXE analysis of such tissue samples. The target samples of exposed tissue slices from a Donryu rat, in which a tumor had been transplanted, were analyzed with proton micro-beams of 2.6 MeV. We report that the shape of cells and the distribution of volatile elements in the tissue sample remain uncharged when using a target preparation based on a freeze-drying method. (author)

  13. Instrumentation for PIXE and RBS

    International Nuclear Information System (INIS)

    2000-12-01

    The purpose of this document is to give an overview of instrumentation for PIXE and Rutherford backscattering analysis, including hardware and software needed to perform the analysis, including detectors, analyzers, data acquisition systems and data analysis software. It also provides some information on accelerators needed for these applications

  14. Expert Images for All Audiences: The AstroPix Archive

    Science.gov (United States)

    Hurt, Robert; Llamas, Jacob; Wyatt, Ryan Jason; Christensen, Lars

    2018-01-01

    The AstroPix project provides one-stop-shopping for an extensive collection of the finest astronomical imagery, sourced from some of the world’s most prominent observatories. The archive is made possible by a grassroots effort to tag publicly-released imagery using the Astronomical Visualization Metadata (AVM) standard, which captures rich contextual information for each image. While the site has been in development for many years, it is now supported under NASA’s Universe of Learning collaboration, and AstroPix has been updated and deployed to cloud services. The AVM tags provide many unique features including spectral color assignments, sky context (using AAS WorldWide Telescope APIs), and direct links to the original source material on the web. The 7,000+ assets currently include imagery provided by Chandra, ESO, GALEX, Herschel, Hubble, NuSTAR, Spitzer, and WISE. The assets are also provided for use in the planetarium community by supporting the Data2Dome (D2D) initiative. AstroPix imagery is designed to be used in a variety of unique ways that benefit formal and informal education as well as astronomers and the general public. Observatories can add their own image archives to AstroPix by tagging their assets and providing a simple XML feed, increasing the value of their data to the community at large.

  15. Late Bronze Age hoard studied by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez Neira, P.C., E-mail: carolina.gutierrez@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Zucchiatti, A., E-mail: alessandro.zucchiatti@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Montero-Ruiz, I., E-mail: ignacio.montero@cchs.csic.es [CCHS-CSIC, Albasanz 26-28, E 28037 Madrid (Spain); Vilaca, R., E-mail: rvilaca@fl.uc.pt [University of Coimbra, Largo da Porta Ferrea, 3000-447 Coimbra (Portugal); Bottaini, C., E-mail: keret18@yahoo.it [University of Coimbra, Largo da Porta Ferrea, 3000-447 Coimbra (Portugal); Gener, M., E-mail: marc.gener@cchs.csic.es [CCHS-CSIC, Albasanz 26-28, E 28037 Madrid (Spain); Climent-Font, A., E-mail: acf@uam.es [CMAM, Universidad Autonoma de Madrid, c/Farady 3, E-28049 Madrid (Spain); Department of Applied Physics, Universidad Autonoma de Madrid, Campus Cantobalanco, E-28049 Madrid (Spain)

    2011-12-15

    The hoards of metallic objects belonging to the Late European Bronze Age can be interpreted differently depending on the type, number and composition of the artefacts. PIXE analysis has been performed in nine items from the Hoard of Freixanda in Portugal comprising four socket axes, a palstave axe, a ring, a chisel, a dagger, and a casting debris. Besides the composition of the main matrix elements, that is Cu and Sn, the amount of trace elements of interest like, As, Pb, Ni, and Ag has been determined using this ion beam technique. The high tin content alloy and the high purity of the metals from the Freixanda hoard are characteristic of the Portuguese and Spanish Late Bronze Age metallurgy, supporting the idea of a regional production.

  16. Prehispanic goldwork technology study by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, Alessandro, E-mail: alessandro.zucchiatti@uam.es [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, Calle de Faraday 3, Madrid 28049 (Spain); Climent Font, Aurelio [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, Calle de Faraday 3, Madrid 28049 (Spain); Gutierrez Neira, Patricia Carolina; Perea, Alicia [Centro de Ciencias Humanas y Sociales, CSIC, Calle Albasanz 26-28, Madrid 28037 (Spain); Fernandez Esquivel, Patricia [Fundación Museos, Banco Central de Costa Rica, San José (Costa Rica); Rovira Llorens, Salvador [Museo Arqueológico Nacional, Calle Serrano 13, Madrid 28006 (Spain); Ruvalcaba Sil, José Luis [Instituto de Física, Universidad Nacional Autónoma de Mexico, Mexici DF 28006 (Mexico); Verde, Ana [Museo de América, Avda. de los Reyes Católicos 6, Madrid 28040 (Spain)

    2014-08-01

    Technological characterization of pre-Hispanic gold metallurgy has still a wide deficit of analytical data. A set of 103 pieces from the so called “Quimbaya’s treasure” (QT) and the “Costa Rica collection” (CRC) of the Museo de America of Madrid were submitted to IBA analysis (PIXE and RBS) at the CMAM in three phases and the metal composition was determined. Only in a limited number of cases, due to the dramatic erosion of the gilded layer, produced by abrasive cleaning methods applied after the discovery and before the seventies, it was possible to determine also the sequence of layers, which gives information on the manufacture technology and the type and purity of the metals. PIXE results are reported and discussed. Data show that the CRC objects have very high gold levels (>80% in weight) while the QT have a more variable composition with significant Cu levels associated to the so called Tumbaga-alloy. In the cases where polishing had a tolerable effect, PIXE (and RBS), point to depletion gilding as a standard finishing process in the Costa Rica production, resulting in a gold rich surface alloy, while the variable composition of the QT objects may well be linked to deliberate colour choice.

  17. PIXE analysis of ancient Chinese Qing dynasty porcelain

    Science.gov (United States)

    Cheng, Huansheng; He, Wenquan; Tang, Jiayong; Yang, Fujia; Wang, Jianhua

    1996-09-01

    The major and minor chemical compositions and trace element content of white glaze made in Qing dynasty at kuan kiln have been determined by PIXE. Experimental results show that trace element contents RbSrZr are useful to distinguish the place of production of ancient porcelain. In the porcelain from different kilns situated in a same province, the trace element contents can be different from each other. Determining and comparing the major and minor compositions and trace elemental concentrations in white glaze by PIXE technique, we can distinguish a precious Qing dynasty porcelain made at kuan kiln from a fake.

  18. Campania Region's Educational Quality Facilities Project

    Science.gov (United States)

    Ponti, Giorgio

    2009-01-01

    This article describes the Educational Quality Facilities project undertaken by Italy's Campania Region to provide quality facilities to all of its communities basing new spaces on the "Flexible Learning Module". The objectives of the five-year project are to: build and equip new educational spaces; improve the quality of existing…

  19. Quantitative elemental imaging of octopus stylets using PIXE and the nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Doubleday, Zoe [Marine Research Laboratories, Tasmanian Aquaculture and Fisheries Institute, University of Tasmania, Private Bag 49, Tasmania 7001 (Australia)], E-mail: zoeanned@utas.edu.au; Belton, David [CSIRO Exploration and Mining, University of Melbourne (School of Physics), Melbourne 3010 (Australia); Pecl, Gretta; Semmens, Jayson [Marine Research Laboratories, Tasmanian Aquaculture and Fisheries Institute, University of Tasmania, Private Bag 49, Tasmania 7001 (Australia)

    2008-01-15

    By utilising targeted microprobe technology, the analysis of elements incorporated within the hard bio-mineralised structures of marine organisms has provided unique insights into the population biology of many species. As hard structures grow, elements from surrounding waters are incorporated effectively providing a natural 'tag' that is often unique to the animal's particular location or habitat. The spatial distribution of elements within octopus stylets was investigated, using the nuclear microprobe, to assess their potential for determining dispersal and population structure in octopus populations. Proton Induced X-ray Emission (PIXE) was conducted using the Dynamic Analysis method and GeoPIXE software package, which produced high resolution, quantitative elemental maps of whole stylet cross-sections. Ten elements were detected within the stylets which were heterogeneously distributed throughout the microstructure. Although Ca decreased towards the section edge, this trend was consistent between individuals and remained homogeneous in the inner region of the stylet, and thus appears a suitable internal standard for future microprobe analyses. Additional analyses used to investigate the general composition of the stylet structure suggested that they are amorphous and largely organic, however, there was some evidence of phosphatic mineralisation. In conclusion, this study indicates that stylets are suitable for targeted elemental analysis, although this is currently limited to the inner hatch region of the microstructure.

  20. Elemental analysis of Uranouchi bay seabed sludge using PIXE

    International Nuclear Information System (INIS)

    Kabir, M. Hasnat; Narusawa, Tadashi; Nishiyama, Fumitaka; Sumi, Katsuhiro

    2006-01-01

    Elemental analyses were carried out for the seabed sludge collected from Uranouchi bay (Kochi, Japan) using Particle Induced X-ray Emission (PIXE). Seabed-sludge contamination with heavy metals as well as toxic elements becomes one of the most serious environmental problems. The aim of the present study is to investigate the polluted areas in the bay by heavy and toxic elements. As a results of analyses of samples collected from eleven different places in the bay, seventeen elements including toxic ones were detected. The results suggest that the center region of the bay is seriously contaminated by heavy and toxic elements in comparison with the other areas in the bay. (author)

  1. Advanced materials analysis facility at CSIRO HIAF laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kenny, M J; Wielunski, L S; Baxter, G R [CSIRO, Lindfield, NSW (Australia). Applied Physics Div.; Sie, S H; Suter, G F [CSIRO, North Ryde, NSW (Australia). Exploration and Mining Div.

    1994-12-31

    The HIAF facility at North Ryde, based on a 3 MV Tandetron accelerator has been operating for several years. Initially three ion sources were in operation:- conventional duoplasmatrons for proton and helium beams and a sputter ion source for heavy ions. An electrostatic focusing system was designed and built in-house for providing microbeams. The research emphasis has been largely on microbeam PIXE with particular reference to the mining industry. An AMS system was added in 1990 which prevented the inclusion of the charge exchange canal required for helium beams. The facility has been operated by CSIRO Division of Exploration and Mining. At the beginning of 1992, the lon Beam Technology Group of CSIRO Division of Applied Physics was relocated at Lindfield and became a major user of the HIAF facility. Because the research activities of this group involved Rutherford Backscattering and Channeling, it was necessary to add a helium ion source and a new high vacuum beam line incorporating a precision goniometer. These facilities became operational in the second quarter of 1992. Currently a PIXE system is being added to the chamber containing the goniometer, making the accelerator an extremely versatile one for a wide range of IBA techniques. 3 refs.

  2. Advanced materials analysis facility at CSIRO HIAF laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kenny, M.J.; Wielunski, L.S.; Baxter, G.R. [CSIRO, Lindfield, NSW (Australia). Applied Physics Div.; Sie, S.H.; Suter, G.F. [CSIRO, North Ryde, NSW (Australia). Exploration and Mining Div.

    1993-12-31

    The HIAF facility at North Ryde, based on a 3 MV Tandetron accelerator has been operating for several years. Initially three ion sources were in operation:- conventional duoplasmatrons for proton and helium beams and a sputter ion source for heavy ions. An electrostatic focusing system was designed and built in-house for providing microbeams. The research emphasis has been largely on microbeam PIXE with particular reference to the mining industry. An AMS system was added in 1990 which prevented the inclusion of the charge exchange canal required for helium beams. The facility has been operated by CSIRO Division of Exploration and Mining. At the beginning of 1992, the lon Beam Technology Group of CSIRO Division of Applied Physics was relocated at Lindfield and became a major user of the HIAF facility. Because the research activities of this group involved Rutherford Backscattering and Channeling, it was necessary to add a helium ion source and a new high vacuum beam line incorporating a precision goniometer. These facilities became operational in the second quarter of 1992. Currently a PIXE system is being added to the chamber containing the goniometer, making the accelerator an extremely versatile one for a wide range of IBA techniques. 3 refs.

  3. PIXE and its applications to biological samples

    International Nuclear Information System (INIS)

    Aldape, F.; Flores, M.J.

    1996-01-01

    Throughout this century, industrialized society has seriously affected the ecology by introducing huge amounts of pollutants into the atmosphere as well as marine and soil environments. On the other hand, it is known that these pollutants, in excess of certain levels of concentration, not only put at risk the life of living beings but may also cause the extinction of some species. It is therefore of basic importance to substantially increase quantitative determinations of trace element concentrations in biological specimens in order to assess the effects of pollutants. It is in this field that PIXE plays a key role in these studies, where its unique analytical properties are decisive. Moreover, since the importance of these research has been recognized in many countries, many scientists have been encouraged to continue or initiate new research programmes aimed to solve the worldwide pollution problem. This document presents an overview of those papers reporting the application of PIXE analysis to biological samples during this last decade of the 20th century and recounts the number of PIXE laboratories dedicating their efforts to find the clues of the biological effects of the presence of pollutants introduced in living beings. Sample preparation methods, different kinds of samples under study and the use of complementary analytical techniques are also illustrated. (author). 108 refs

  4. PIXE and XRF Analysis of Roman Denarii

    Science.gov (United States)

    Fasano, Cecilia; Raddell, Mark; Manukyan, Khachatur; Stech, Edward; Wiescher, Michael

    2017-09-01

    A set of Roman Denarii from the republican to the imperial period (140BC-240AD) has been studied using X-ray fluorescent (XRF) scanning and proton induced x-ray emission (PIXE) techniques. XRF and PIXE are commonly used in the study of cultural heritage objects because they are nondestructive. The combination of these two methods is also unique because of the ability to penetrate the sample with a broader spectrum of depths and energies than either could achieve on its own. The coins are from a large span of Roman history and their analysis serves to follow the economic and political change of the era using the relative silver and copper contents in each sample. In addition to analyzing the samples, the study sought to compare these two common analysis techniques and to explore the use of a standard to examine any shortcomings in either of the methods. Data sets were compared and then adjusted to a calibration curve which was created from the analysis of a number of standard solutions. The concentrations of the standard solutions were confirmed using inductively coupled plasma spectroscopy. Through this we were able to assemble results which will progress the basis of understanding of PIXE and XRF techniques as well as increase the wealth of knowledge of Ancient Roman currency.

  5. Fish gelatin thin film standards for biological application of PIXE

    Science.gov (United States)

    Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.

    2014-08-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12C(p,p)12C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.

  6. Fish gelatin thin film standards for biological application of PIXE

    International Nuclear Information System (INIS)

    Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.

    2014-01-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12 C(p,p) 12 C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition

  7. Fish gelatin thin film standards for biological application of PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Manuel, Jack E., E-mail: jaelma@gmail.com [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States); Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States); Deaton, James; Luyombya, Henry [Louisiana Accelerator Center, University of Louisiana at Lafayette, Lafayette, LA 70503 (United States); Briski, Karen P. [Department of Basic Pharmaceutical Sciences, University of Louisiana at Monroe, Monroe, LA 71209 (United States); Glass, Gary A. [Ion Beam Modification and Analysis Laboratory, University of North Texas, Denton, TX 76203 (United States)

    2014-08-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon {sup 12}C(p,p){sup 12}C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.

  8. PIXE-quantified AXSIA: Elemental mapping by multivariate spectral analysis

    International Nuclear Information System (INIS)

    Doyle, B.L.; Provencio, P.P.; Kotula, P.G.; Antolak, A.J.; Ryan, C.G.; Campbell, J.L.; Barrett, K.

    2006-01-01

    Automated, nonbiased, multivariate statistical analysis techniques are useful for converting very large amounts of data into a smaller, more manageable number of chemical components (spectra and images) that are needed to describe the measurement. We report the first use of the multivariate spectral analysis program AXSIA (Automated eXpert Spectral Image Analysis) developed at Sandia National Laboratories to quantitatively analyze micro-PIXE data maps. AXSIA implements a multivariate curve resolution technique that reduces the spectral image data sets into a limited number of physically realizable and easily interpretable components (including both spectra and images). We show that the principal component spectra can be further analyzed using conventional PIXE programs to convert the weighting images into quantitative concentration maps. A common elemental data set has been analyzed using three different PIXE analysis codes and the results compared to the cases when each of these codes is used to separately analyze the associated AXSIA principal component spectral data. We find that these comparisons are in good quantitative agreement with each other

  9. PIXE analysis of chinese chicken-blood stone

    International Nuclear Information System (INIS)

    Lin, E.K.; Wang, C.W.; Yu, Y.C.; Liu, T.Y.; Cheng, H.S.; Zhu, H.X.; Yang, H.J.

    1999-01-01

    This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al 2 O 3 and SiO 2 . The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

  10. PIXE and the mysteries of Legionnaires' disease

    International Nuclear Information System (INIS)

    Chen, J.R.

    1981-01-01

    The authors describe the use of proton-induced X-ray emission (PIXE) to analyse the nickel concentrations of the autopsy specimens from victims of Legionnaires' disease. They show that the high nickel concentrations in the lung specimens from the first recognized Legionnaires' cases in Philadelphia in 1976 were due to contamination during the autopsies. Recently the authors have used PIXE to show that the selenium concentrations in the sera of the acutely ill Legionnaires' patients are significantly lower than in their matching convalescent-phase sera. This finding may be related to the patient's response to the disease or to the specific characteristics of the Legionella pneumophila itself. Studies show that the disease is not a rare illness but a worldwide one. General criteria concerning specimen collection are described

  11. Holistic RBS-PIXE data reanalysis of SBT thin film samples

    International Nuclear Information System (INIS)

    Reis, M.A.; Barradas, N.P.; Pascual-Izarra, C.; Chaves, P.C.; Ramos, A.R.; Alves, E.; Gonzalez-Aguilar, G.; Costa, M.E.V.; Miranda Salvado, I.M.

    2007-01-01

    The growth of SrBi 2 Ta 2 O 9 (SBT) films on top of Pt electrode substrates is an important issue for the fabrication of ferroelectric based memories. In a recent publication, SBT thin films grown using seeded and unseeded procedures were studied by PIXE and RBS. Difficulties and misfits found in the comparison of results from both techniques were, at that time, overcome by physical considerations. These, although not rendering interpretation impossible, left out the possibility of understanding the exact nature of the differences between the interface behavior in each case. In the present work it is shown that the reanalysis of the same data using the recently developed RBS-PIXE simultaneous and self-consistent calculation present in NDF leads to stronger conclusions on the solid state reaction occurring during the deposition stage for both types of samples. Allowing for the occurrence of solid state reactions between the deposited film and the Pt electrode even in the case of seeded samples leads to a full explanation of IBA data, this result showing that in complex systems such as this, the PIXE data are essential and must be integrated with the RBS data in an holistic analysis, in order to properly unfold the depth profile of the samples. Contrary to what is usually supposed PIXE data is therefore shown to contain hidden depth structure information

  12. PIXE analysis of umeboshi (dried plum)

    International Nuclear Information System (INIS)

    Tsuboi, S.; Ishii, K.; Matsuyama, S.

    2008-01-01

    In recent years, the self-sufficiency ratio of food in Japan has gradually decreased and 60% of foods are now imported from abroad. Japanese people rely strongly upon imported food and should take care of their safety, but what is happening now is that soil pollution in country of origin grows into a serious problem and can affect imported food. Umeboshi is one of the traditional pickled food in Japan and very popular. In the case of umeboshi, more than 65% of it is imported. We analyzed imported umeboshi and domestic ones by using in-air PIXE system and submili-PIXE camera at Tohoku University. In this experiment, the concentrations of toxic heavy metals such as As, Cd, Hg and Pb were lower than standard values given by a food hygiene law. Concentrations of elements heavier than Ca show similar trend among each sample. On the other hand, lighter elements than Ca show large differences, which is related to food coloring or processing technique. (author)

  13. Characterization of human fingernail elements using PIXE technique

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Ajose, O.A.; Makinde, N.O.; Buoso, M.C.; Ceccato, D.; De Poli, M.; Moschini, G.

    2005-01-01

    PIXE technique was employed in the determination of the major, minor and trace elemental concentrations in finger-nails of 62 healthy young adults (30 females and 32 males), aged between 20 and 37 years. The elemental concentrations in the nails of the analyzed population provide good reference data set for further health studies. The PIXE measurements were carried out using 1.8 MeV collimated proton beam from the 2.5 MV AN-2000 Van de Graaff accelerator at INFN, LNL, Legnaro (Padova), Italy. The results show the presence of twenty elements. Their metabolic roles in humans are presented and discussed. The comparison of our results with those of other authors are also presented

  14. Differential PIXE for investigating the layer structure of paintings

    Science.gov (United States)

    Mandò, P. A.; Fedi, M. E.; Grassi, N.; Migliori, A.

    2005-09-01

    This paper reports an example of how the differential PIXE technique can be successfully applied to the investigation of wood or canvas paintings. The work analysed is a famous wood painting by Leonardo da Vinci, the "Madonna dei fusi" (ex-Reford version, 1501), chosen for a pilot study in a wide international project aimed at analysing Leonardo's works of art by means of non-destructive techniques. While illustrating the results obtained concerning the identification of pigments and the discrimination of the stratigraphy of layers, the merits and limits of differential PIXE in general are pointed out.

  15. Differential PIXE for investigating the layer structure of paintings

    International Nuclear Information System (INIS)

    Mando, P.A.; Fedi, M.E.; Grassi, N.; Migliori, A.

    2005-01-01

    This paper reports an example of how the differential PIXE technique can be successfully applied to the investigation of wood or canvas paintings. The work analysed is a famous wood painting by Leonardo da Vinci, the 'Madonna dei fusi' (ex-Reford version, 1501), chosen for a pilot study in a wide international project aimed at analysing Leonardo's works of art by means of non-destructive techniques. While illustrating the results obtained concerning the identification of pigments and the discrimination of the stratigraphy of layers, the merits and limits of differential PIXE in general are pointed out

  16. PIXE analysis of caries related trace elements in tooth enamel

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Jodaikin, A.; Cleaton-Jones, P.E.; Sellschop, J.P.F.; Madiba, C.C.P.; Bibby, D.; University of the Witwatersrand, Johannesburg

    1981-01-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis. (orig.)

  17. Development of sample preparation method for honey analysis using PIXE

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Chiba, Keiko; Sera, Koichiro

    2008-01-01

    We developed an original preparation method for honey samples (samples in paste-like state) specifically designed for PIXE analysis. The results of PIXE analysis of thin targets prepared by adding a standard containing nine elements to honey samples demonstrated that the preparation method bestowed sufficient accuracy on quantitative values. PIXE analysis of 13 kinds of honey was performed, and eight mineral components (Si, P, S, K, Ca, Mn, Cu and Zn) were detected in all honey samples. The principal mineral components were K and Ca, and the quantitative value for K accounted for the majority of the total value for mineral components. K content in honey varies greatly depending on the plant source. Chestnuts had the highest K content. In fact, it was 2-3 times that of Manuka, which is known as a high quality honey. K content of false-acacia, which is produced in the greatest abundance, was 1/20 that of chestnuts. (author)

  18. PIXE analysis of caries related trace elements in tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Annegarn, H J; Jodaikin, A; Cleaton-Jones, P E; Sellschop, J P.F.; Madiba, C C.P.; Bibby, D [University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit; University of the Witwatersrand, Johannesburg (South Africa). Dental Research Unit)

    1981-03-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis.

  19. Study of stained glass window using PIXE-PIGE

    International Nuclear Information System (INIS)

    Weber, G.; Bemden, Y. Vanden; Pirotte, M.; Gilbert, B.

    2005-01-01

    We had the opportunity to study a large panel (100x80cm) containing more than 40 stained glass pieces. Among them several come from restorations having taken place at different periods. The study of this rather complex arrangement has been processed by stages:- the elemental composition of 16 zones were determined: several differences were identified and among them the Na/K ratio which allowed to set three groups of glass type; - the measurement of the Na concentrations by the two techniques give information in bulk (PIGE) and at the near surface (PIXE); the values defined by the (C PIGE -C PIXE) )/C PIGE plotted in function of the historical estimation of the age of the stained glass pieces (original and restored) indicate a real correlation between the two variables; - the red-colored pieces were specially investigated in order to determine which coloration technique was employed (bulk coloration, superficial staining, multilayered flashing, etc.); - the corrosion was investigated by scanning two different worsened zones with a 0.5mm diameter beam spot. This study shows the possibilities of the PIGE-PIXE association, but also points out some weaknesses, which have to be solved by other techniques; unfortunately, in that case, the non-destructive aspect could be lost

  20. Region 7 Title V facilities

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web map shows the Region 7 Title V facilities (Clean Air Act major sources), any Class I areas within 300 km of R7 States, and any Tribal areas within 50 miles...

  1. Proton induced X-ray emission (PIXE) analysis at Lucas Heights

    International Nuclear Information System (INIS)

    Cohen, D.; Duerden, P.

    1979-02-01

    The state of the proton induced X-ray emission (PIXE) work at Lucas Heights is reported together with a full description of the experimental arrangement and its use for analysis of trace elements (Z >or= 14). The fundamentals of PIXE are examined in detail with a view to understanding not only the background continuum but also the X-ray production mechanisms. Quantitative predictions for the number of X-rays detected after proton bombardment of the target have been made and these compare well with experiments

  2. A forensic application of PIXE analysis

    International Nuclear Information System (INIS)

    Kravchenko, I.I.; Dunnam, F.E.; Rinsvelt, H.A. van; Warren, M.W.; Falsetti, A.B.

    2001-01-01

    PIXE measurements were performed on various calcareous materials including identified bone residues, human cremains, and samples of disputed origin. In a forensic application, the elemental analysis suggests that the origin of a sample suspectly classified as human cremains can tentatively be identified as a mixture of sandy soil and dolomitic limestone

  3. Construction of a PIXE database for supporting PIXE studies. Database of experimental conditions and elemental concentration for various samples

    International Nuclear Information System (INIS)

    Itoh, J.; Saitoh, Y.; Futatsugawa, S.; Sera, K.; Ishii, K.

    2007-01-01

    A database of PIXE data, which have been accumulated at NMCC, has been constructed. In order to fill up the database, data are newly obtained as many as possible for the kind of samples whose number is small. In addition, the data for different measuring conditions are obtained for several samples. As the number of γ-ray spectrum obtained with a HPGe detector for the purpose of analyzing light elements such as fluorine, is overwhelmingly small in comparison with that of usual PIXE spectra, γ-ray spectrum and elemental concentration of fluorine are obtained as many as possible for food, environmental and hair samples. In addition, the data taken with an in-air PIXE system have been obtained for various samples. As a result, the database involving contents over various research fields is constructed, and it is expected to be useful for researches who make use of analytical techniques. It is expected that this work will give a start to many researchers to participate in the database and to make calibration with each other in order to establish reliable analytical techniques. Moreover, the final goal of the database is to establish the control concentration values for typical samples. As the first step of establishing the control values, average elemental concentration and its standard deviations in hair samples taken from 405 healthy Japanese are obtained and tabulated according to their sex and age. (author)

  4. Limited angle STIM and PIXE tomography of single cells

    International Nuclear Information System (INIS)

    Andrea, T.; Rothermel, M.; Werner, R.; Butz, T.; Reinert, T.

    2010-01-01

    STIM (scanning transmission ion microscopy) tomography has been shown to be a valuable method for the three-dimensional characterization of microsamples. It has, however, rarely been employed for the study of single cells, since a free-standing sample is needed for an ordinary tomography experiment. This requirement places high demands on sample preparation techniques. In this study cells fixated on a substrate rather than free-standing were used for tomography. Since the substrate prevented a full rotation of the sample an algorithm for limited-angle tomography was devised. STIM projections covering only a limited angular range of ca. 120 o were supplemented with simulated projections generated from a back and forth iteration between real space and Radon space. The energy loss caused by the substrate was subtracted from each projection. The cells were reconstructed using filtered backprojection. The surface of the cells as well as some interior structures could be reconstructed. Following the STIM projections a lesser number of PIXE (particle induced X-ray emission) projections were taken in order to obtain information about the elemental distribution of the sample. From the PIXE projections the three-dimensional phosphorus distribution within the cell was reconstructed using limited-angle tomography. Superimposition of the STIM and PIXE tomograms revealed the location of intracellular structures. Whereas STIM tomography is sensitive to density contrast, which are greatest at the surface, PIXE tomography is sensitive to changes in elemental concentration. Hence, the combination of the two methods can be very fruitful, while the limited angle approach can compensate some of the difficulties associated with tomography of single cells, namely preparation difficulties and excessive sample damage.

  5. Parameter determination for quantitative PIXE analysis using genetic algorithms

    International Nuclear Information System (INIS)

    Aspiazu, J.; Belmont-Moreno, E.

    1996-01-01

    For biological and environmental samples, PIXE technique is in particular advantage for elemental analysis, but the quantitative analysis implies accomplishing complex calculations that require the knowledge of more than a dozen parameters. Using a genetic algorithm, the authors give here an account of the procedure to obtain the best values for the parameters necessary to fit the efficiency for a X-ray detector. The values for some variables involved in quantitative PIXE analysis, were manipulated in a similar way as the genetic information is treated in a biological process. The authors carried out the algorithm until they reproduce, within the confidence interval, the elemental concentrations corresponding to a reference material

  6. PIXE analysis of human stones: comparison with data from ICP-AES

    International Nuclear Information System (INIS)

    Pougnet, M.A.B.; Peisach, M.; Pineda, C.A.; Rodgers, A.L.

    1987-01-01

    25 human stone samples previously analyzed by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and the IAEA Animal Bone Standard Reference Material were used to evaluate trace element analysis by PIXE. Bombardment with 4 MeV protons was used for the determination of Mn, Fe, Cu, Pb, Br, Rb, Sr and Ca. PIXE and ICP-AES data gave correlation factors better than 0.97 for the elements Ca, Fe, Zn, Sr and Pb. (author) 9 refs.; 5 figs

  7. LibCPIXE: A PIXE simulation open-source library for multilayered samples

    International Nuclear Information System (INIS)

    Pascual-Izarra, C.; Barradas, N.P.; Reis, M.A.

    2006-01-01

    Most particle induced X-ray emission (PIXE) data analysis codes are not focused on handling multilayered samples. We have developed an open-source library called 'LibCPIXE', for PIXE data analysis. It is written in standard C and implements functions for simulating X-ray yields of PIXE spectra taken from arbitrary samples, including multilayered targets. The library is designed to be fast, portable, modular and scalable, as well as to facilitate its incorporation into any existing program. In order to demonstrate the capabilities of the library, a program called CPIXE was developed and used to analyze various real samples involving both bulk and layered samples. Just as the library, the CPIXE source code is freely available under the General Public License. We demonstrate that it runs both under GNU/Linux systems as well as under MS Windows. There is in principle no limitation to port it to other platforms

  8. The new dedicated PIXE set-up at the National Environmental Research Institute, Denmark

    International Nuclear Information System (INIS)

    Kemp, Ka ring re; Waahlin, Peter

    1999-01-01

    The Niels Bohr Institute in Copenhagen was in the beginning of the 70'es one of the early places for PIXE. Contributions were made to the theoretical interpretation of the PIXE spectra as well as the practical application. The home-made 4 MV van de Graaff accelerator at the Niels Bohr Institute was an excellent tool for PIXE. The accelerator, which was used for many years, has now found its place on a museum after more than 40 years of active service. A dedicated PIXE set-up has now been established at the National Environmental Research Institute using a new 1.7 MV Tandem Pelletron (5SDH) from NEC. The main application is elemental analysis of outdoor aerosols. The main work is unsophisticated macro analyses, which do not push the equipment to its limits. This enables automated analysis of about 10,000 samples per year using very limited manpower resources. The research focuses on the contribution from various source types to the atmosphere over Europe, the North Atlantic and Greenland. Source compositions and their temporal variations are studied

  9. A novel preconcentration technique for the PIXE analysis of water

    International Nuclear Information System (INIS)

    Savage, J.M.; Robertson, J.D.; Majidi, V.

    1994-01-01

    The potential of using dried algae as a novel preconcentration technique for the analysis of water samples by PIXE was examined. 5 mg of dried algae powder were mixed with 5 mL of single- and multi-metal solutions. The algae cells were then collected by filtration on 0.6 um polycarbonate membranes and analyzed by PIXE using a dual energy irradiation. When C. vulgatis was used on mixed metal solutions, linear responses were observed for Ag + , Ba 2+ , and Cd 2+ in the concentration range from 10 ng/g to 1 ug/g; for Cu 2+ and Pb 2+ from 10 ng/g to 5 ug/g; and for Hg 2+ from 10 ng/g to 10 ug/g. When S. bacillaris was used, linear responses were observed from 10 ng/g up to 10 ug/g for all of the metal cations investigated. The PIXE results demonstrated that metal binding at low concentrations involves replacement of sodium on the cell wall and that at high concentrations magnesium is also replaced

  10. Environmental applications of PIXE at the Institute of Physics, UNAM

    International Nuclear Information System (INIS)

    Solis, C.; Mireles, A.; Andrade, E.; Zolezzi R, H.

    2007-01-01

    The particle induced X-ray emission technique (PIXE), developed by Johansson and colleagues in Lund, Sweden, in the 70's has been used since then in a high number of studies requiring detection and quantification of trace elements at high sensitivity (better than I mg/kg). PIXE is grouped among the nuclear analytical techniques because the samples are bombarded with particles (protons generally) accelerated in an accelerator. When protons interact with matter an X-Ray spectrum is produced by the deexcitation of atoms in the sample. From this spectrum the elements contained in the sample as well as their concentrations can be determined. In this work we describe the PIXE technique and several applications in the environmental field developed at the Institute of Physics of the National Autonomous University of Mexico (IFUNAM). These practical applications include field studies for analyses of suspended particles in air using tree leaves, irrigation water quality based on heavy metal analyses, and analyses of trace elements in plants cultivated in waste water irrigated soil. (Author)

  11. PIXE studies of osteoporosis preventive treatments

    International Nuclear Information System (INIS)

    Ynsa, M.D.; Pinheiro, T.; Ager, F.J.; Alves, L.C.; Millan, J.C.; Gomez-Zubelbia, M.A.; Respaldiza, M.A.

    2002-01-01

    Particle induced X-ray emission (PIXE) and nuclear microprobe (NMP) have been used in an exploratory work to study elemental alterations in tissues of experimental animals submitted to osteoporosis preventive treatments. Osteopathologies have been associated with several factors, such as hormonal disturbances, metabolic aberrations, low dietary Ca and vitamin D intake, excess of iron, among other possible factors. Hormonal treatments seem to be beneficial to the incorporation of Ca in bone but breast and endometrial cancers constitute significant side effects that cannot be ignored. Wistar female rats were used to test the effect of estrogen therapy in osteoporosis progression. The variations of elemental concentrations in uterus and the Ca content of femoral bones of ovariectomised rats under estrogen therapy were investigated. PIXE, Rutherford backscattering spectrometry and secondary electron microscopy techniques were applied for the characterisation of biological materials, with respect to morphology and trace element distribution determination. The increase of Ca and Fe concentrations in uterus and the variations for Ca distribution patterns in bone of rats submitted to estrogen therapy were the major features observed

  12. Analytical Methods INAA and PIXE Applied to Characterization of Airborne Particulate Matter in Bandung, Indonesia

    Directory of Open Access Journals (Sweden)

    D.D. Lestiani

    2011-08-01

    Full Text Available Urbanization and industrial growth have deteriorated air quality and are major cause to air pollution. Air pollution through fine and ultra-fine particles is a serious threat to human health. The source of air pollution must be known quantitatively by elemental characterization, in order to design the appropriate air quality management. The suitable methods for analysis the airborne particulate matter such as nuclear analytical techniques are hardly needed to solve the air pollution problem. The objectives of this study are to apply the nuclear analytical techniques to airborne particulate samples collected in Bandung, to assess the accuracy and to ensure the reliable of analytical results through the comparison of instrumental neutron activation analysis (INAA and particles induced X-ray emission (PIXE. Particle samples in the PM2.5 and PM2.5-10 ranges have been collected in Bandung twice a week for 24 hours using a Gent stacked filter unit. The result showed that generally there was a systematic difference between INAA and PIXE results, which the values obtained by PIXE were lower than values determined by INAA. INAA is generally more sensitive and reliable than PIXE for Na, Al, Cl, V, Mn, Fe, Br and I, therefore INAA data are preffered, while PIXE usually gives better precision than INAA for Mg, K, Ca, Ti and Zn. Nevertheless, both techniques provide reliable results and complement to each other. INAA is still a prospective method, while PIXE with the special capabilities is a promising tool that could contribute and complement the lack of NAA in determination of lead, sulphur and silicon. The combination of INAA and PIXE can advantageously be used in air pollution studies to extend the number of important elements measured as key elements in source apportionment.

  13. Analytical Methods INAA and PIXE Applied to Characterization of Airborne Particulate Matter in Bandung, Indonesia

    International Nuclear Information System (INIS)

    Lestiani, D.D.; Santoso, M.

    2011-01-01

    Urbanization and industrial growth have deteriorated air quality and are major cause to air pollution. Air pollution through fine and ultra-fine particles is a serious threat to human health. The source of air pollution must be known quantitatively by elemental characterization, in order to design the appropriate air quality management. The suitable methods for analysis the airborne particulate matter such as nuclear analytical techniques are hardly needed to solve the air pollution problem. The objectives of this study are to apply the nuclear analytical techniques to airborne particulate samples collected in Bandung, to assess the accuracy and to ensure the reliable of analytical results through the comparison of instrumental neutron activation analysis (INAA) and particles induced X-ray emission (PIXE). Particle samples in the PM 2.5 and PM 2.5-10 ranges have been collected in Bandung twice a week for 24 hours using a Gent stacked filter unit. The result showed that generally there was a systematic difference between INAA and PIXE results, which the values obtained by PIXE were lower than values determined by INAA. INAA is generally more sensitive and reliable than PIXE for Na, Al, Cl, V, Mn, Fe, Br and I, therefore INAA data are preferred, while PIXE usually gives better precision than INAA for Mg, K, Ca, Ti and Zn. Nevertheless, both techniques provide reliable results and complement to each other. INAA is still a prospective method, while PIXE with the special capabilities is a promising tool that could contribute and complement the lack of NAA in determination of lead, sulphur and silicon. The combination of INAA and PIXE can advantageously be used in air pollution studies to extend the number of important elements measured as key elements in source apportionment. (author)

  14. PIXE analysis of exhaust gas from diesel engine

    International Nuclear Information System (INIS)

    Miyake, Hirosi; Michijima, Masami; Onishi, Masayuki; Fujitani, Tatsuya.

    1986-01-01

    The variation of elemental concentrations in exhaust gas of a Diesel engine with the outputs was studied. Particulates in high temperature gas were collected on silica fiber filters and analyzed by PIXE method. Concentrations of S and V were nearly proportional to particulate masses and fuel consumption rates per discharging rates of exhaust gas respectively. While, concentrations of Fe and Mn were markedly increased together with engine outputs, and Mn/Fe ratios were nearly equal to those of the material of piston rings and the cylinder liner. Concentrations of the elements contained in lubricant, such as Ca and Mo, were also conspicuously increased with the outputs. It was shown that PIXE analysis is a useful tool for engine diagonostics owing to its high sensitive multi-elemental availability without chemical treatments. (author)

  15. PIXE in 1980: Summary of the second international conference on particle induced x-ray emission and its analytical applications

    International Nuclear Information System (INIS)

    Akselsson, K.R.

    1981-01-01

    The Second International Conference on Particle Induced X-ray Emission (PIXE) and its analytical applications was held in Lund, Sweden, June 9-12, 1980. About a hundred papers were presented, including seven invited talks (PIXE and particle scattering, microbeam analysis, applications to aerosols and biological samples). The main impression left by the conference was that both the PIXE method and its applications are in a phase of fast development. Considerable effort has successfully been devoted to optimizing the basic PIXE technique. Also the great advantage of simultaneously getting information about lighter elements and sample mass was reported to have been successfully employed in routine analyses. PIXE, which was initially considered to be a method mainly for thin samples, has also been shown to be competitive for a variety of thick samples. Data from aerosol studies was presented. With the PIXE-method, it is feasible to perform series of measurements over a long period of time, many samples in parallel and/or samples from sites of poor accessibility. However, the advantages of PIXE may be further exploited in aerosol investigations and some promising lines of sampler development were reported. Sample preparation techniques are crucial for applications to biological samples and several laboratories are engaged in such developmental work. However, it was also evident that PIXE is already giving significant contributions to research in biology and medicine

  16. Trace element fingerprinting of jewellery rubies by external beam PIXE

    International Nuclear Information System (INIS)

    Calligaro, T.; Poirot, J.-P.; Querre, G.

    1999-01-01

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations

  17. Trace element fingerprinting of jewellery rubies by external beam PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Calligaro, T. E-mail: calli@culture.nl; Poirot, J.-P.; Querre, G

    1999-04-02

    External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies: one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional geological observations.

  18. Preliminary report on the PIXE analysis of the squid statoliths

    International Nuclear Information System (INIS)

    Ikeda, Yuzuru; Arai, Nobuaki; Sakamoto, Wataru; Murayama, Tatsuro; Maeda, Kuniko; Yoshida, Koji.

    1996-01-01

    Micro trace elements in the squid statolith, a calcareous stone which acts as a balancer and hearing, was analyzed with Particle Induced X-ray Emission (PIXE) for the Japanese common squid for the first time. Calcium is the main component of the squid statoliths, which means that squid statolith is the pure calcified structure similar to the fish otolith. Beside Ca, Sr was detected with strong dosage, and some other elements as Mn, Fe, Cu, Zn and As were also detected. Possible assumption of intake of microelements to the statoliths and the suitability of PIXE for statoliths analysis are discussed. (author)

  19. Micro-PIXE studies of char populations in northern Canada

    International Nuclear Information System (INIS)

    Campbell, J.L.; Babaluk, J.A.; Halden, N.M.; Kristofferson, A.H.; Maxwell, J.A.; Mejia, S.R.; Reist, J.D.; Teesdale, W.J.

    1999-01-01

    Micro-PIXE analysis of trace elements in otoliths has been used as the basis for several projects on char, a fish that is important for aboriginal subsistence fisheries in Arctic Canada. Life-history patterns were originally inferred from micro-PIXE line scans of Sr distribution. These were confirmed by superposition of Sr distribution patterns on optical images of otoliths of tag-recaptured fish. Char from various populations showed differentiation in otolith primordial Sr concentration; this enables us to differentiate biological stocks and, it is hoped, eventually to assign individuals from mixed-stock fisheries to their stock of origin. Zn oscillations also correlate with annular structure and provide additional temporally constrained information on fish habitat and behaviour

  20. Analysis of bone marrow stromal cell transferred bacterial {beta}-galactosidase gene by PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Kumakawa, Toshiro [Tokyo Metropolitan Geriatric Hospital, Tokyo (Japan). Dept. of Blood Transfusion and Hematology; Hibino, Hitoshi; Tani, Kenzaburo; Asano, Shigetaka; Futatugawa, Shouji; Sera, Kouichiro

    1997-12-31

    PIXE, Particle Induced X-ray Emission, is a powerful, multi-elemental analysis method which has many distinguishing features and has been used in varies research fields. Recently the method of applying baby cyclotrons for nuclear medicine to PIXE has been developed. This enables us to study biomedical phenomena from the physical point of view. Mouse bone marrow stromal cells were transferred bacterial {beta}-galactosidase gene (LacZ gene) by murine retroviral vectors. Analysis of the bone marrow stromal cells with the LacZ gene by PIXE revealed remarkable changes of intracellular trace elements compared with the normal control cells. These results indicate that gene transfer by retroviral vectors may bring about a dynamic change of intracellular circumstances of the target cell. (author)

  1. On the autarchic use of solely PIXE data in particulate matter source apportionment studies by receptor modeling

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN)-Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Nava, S., E-mail: nava@fi.infn.it [National Institute of Nuclear Physics (INFN)-Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Calzolai, G. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Chiari, M. [National Institute of Nuclear Physics (INFN)-Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Giannoni, M.; Traversi, R.; Udisti, R. [Department of Chemistry, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Italy)

    2015-11-15

    Particle Induced X-ray Emission (PIXE) analysis of aerosol samples allows simultaneous detection of several elements, including important tracers of many particulate matter sources. This capability, together with the possibility of analyzing a high number of samples in very short times, makes PIXE a very effective tool for source apportionment studies by receptor modeling. However, important aerosol components, like nitrates, OC and EC, cannot be assessed by PIXE: this limitation may strongly compromise the results of a source apportionment study if based on PIXE data alone. In this work, an experimental dataset characterised by an extended chemical speciation (elements, EC–OC, ions) is used to test the effect of reducing input species in the application of one of the most widely used receptor model, namely Positive Matrix Factorization (PMF). The main effect of using only PIXE data is that the secondary nitrate source is not identified and the contribution of biomass burning is overestimated, probably due to the similar seasonal pattern of these two sources.

  2. New Generation GridPix: Development and characterisation of pixelated gaseous detectors based on the Timepix3 chip

    CERN Document Server

    AUTHOR|(CDS)2082958; Hessey, Nigel

    Due to the increasing demands of high energy physics experiments there is a need for particle detectors which enable high precision measurements. In this regard, the GridPix detector is a novel detector concept which combines the benefits of a pixel chip with an integrated gas amplification structure. The resulting unit is a detector sensitive to single electrons with a great potential for particle tracking and energy loss measurements. This thesis is focusing on the development of a new generation of GridPix detectors based on the Timepix3 chip, which implements a high resolution Time to Digital Converter (TDC) in each pixel. After an introductory chapter describing the motivation behind GridPix, the manuscript presents the physics of gaseous detectors in chapter 2 along with the gaseous detectors used for particle tracking in chapter 3. Chapters 4 and 5 are focusing on the tracking performance of GridPix detectors. Chapter 4 presents results obtained with a GridPix detector based on a small scale prototy...

  3. External-beam PIXE analysis of small sculptures

    International Nuclear Information System (INIS)

    Gyodi, I.; Demeter, I.; Hollos-Nagy, K.; Kovacs, I.; Szokefalvi-Nagy, Z.

    1999-01-01

    Non-destructive analysis of precious art objects is an important tool to solve provenance problems or to facilitate restoration. External beam PIXE analysis is one of the most powerful and popular methods used in this respect. The paper summarises the external beam PIXE set-up at the Accelerator Laboratory in Budapest, and two selected applications are described. Different parts of a small Cambodian metal sculpture probably made in the 11th century were analysed. It was observed that the sculpture was composed of an iron core and an outer bronze shell. This sculptural technique was well known in the Middle-East but no indication has been found about its use in the Far-East, yet. Before its restoration paint traces on a wooden relief of St. Jerome made by an unknown artist in about 1600 were analysed. Different white and red paints were distinguished at selected points and the presence of titanium on a certain part of the relief was attributed to a repainting in modern times

  4. Chemical composition of a yellowish rainfall by the application of PIXE and micro-PIXE technique

    International Nuclear Information System (INIS)

    Ma, C.-J.

    2006-01-01

    Information of the chemical properties of rain fallen during the Asian dust (AD) event will help us to better understand the wet scavenging processes of dust particles. In this study, the chemical characteristics of rainwater and individual raindrops fallen during the AD storm have been investigated. The yellowish rainwater and individual raindrops were collected simultaneously in Kyoto, Japan on 7 April 2001. Particle induced X-ray emission (PIXE) was employed in the determination of chemical properties of soluble and insoluble fractions of rainwater. In addition, micro-PIXE was applied to the chemical analysis of residual materials retained in the initial individual raindrops. The pH level of yellowish rainwater was measured around 6.7. In compliance with the general expectation, major components in rainwater were of soil-origin such as Si, K, Ca, Ti and Fe. These soil-related components contributed to as much as 92% of total elemental composition in both soluble and insoluble fractions. By scanning a micro-beam, the residual particle cluster in individual raindrops was reconstructed in terms of an elemental map. This visualized elemental map in fact enabled us not only to estimate the chemical mixing state of raindrop residual particles but also to presume the wet scavenging of dust particles by rainfall

  5. Optimization of PIXE-sensitivity for detection of Ti in thin human skin sections

    International Nuclear Information System (INIS)

    Pallon, Jan; Garmer, Mats; Auzelyte, Vaida; Elfman, Mikael; Kristiansson, Per; Malmqvist, Klas; Nilsson, Christer; Shariff, Asad; Wegden, Marie

    2005-01-01

    Modern sunscreens contain particles like TiO 2 having sizes of 25-70 nm and acting as a reflecting substance. For cosmetic reasons the particle size is minimized. Questions have been raised to what degree these nano particles penetrate the skin barrier, and how they do affect the human. The EU funded project 'Quality of skin as a barrier to ultra-fine particles' - NANODERM has started with the purpose to evaluate the possible risks of TiO 2 penetration into vital skin layers. The purpose of the work presented here was to find the optimal conditions for micro-PIXE analysis of Ti in thin skin sections. In the skin region where Ti is expected to be found, the naturally occurring major elements phosphorus, chlorine, sulphur and potassium have steep gradients and thus influence the X-ray background in a non-predictable manner. Based on experimental studies of Ti-exposed human skin sections using proton energies ranging from 1.8-2.55 MeV, the corresponding PIXE detection limits for Ti were calculated. The energy that was found to be the most favourable, 1.9 MeV, was then selected for future studies

  6. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques.

    Science.gov (United States)

    Venkateswara Rao, R; Venkateswarulu, P; Kasipathi, C; Sivajyothi, S

    2013-12-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. © 2013 Elsevier Ltd. All rights reserved.

  7. PIXE analysis of Nigerian flour and bread samples

    Energy Technology Data Exchange (ETDEWEB)

    Olise, Felix S., E-mail: felix_olise@rushpost.com [Department of Physics, Obafemi Awolowo University, Ile-Ife 220005 (Nigeria); Fernandes, Adriana M.; Cristina Chaves, P. [CFA: Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal); Taborda, Ana; Reis, Miguel A. [IST/CTN: Instituto Superior Técnico, Universidade Técnica de Lisboa, Campus Tecnológico e Nuclear (CTN), EN10, 2686-953 Sacavém (Portugal); CFA: Centro de Física Atómica da Universidade de Lisboa, Av. Prof. Gama Pinto 2, 1649-003 Lisboa (Portugal)

    2014-01-01

    Highlights: • The PIXE technique has been used to determine K and Br in a major Nigerian food item. • Samples were analysed using two proton beam energies, namely 1.25 MeV and 2.15 MeV. • Mismatched Ca results reflect its nature and accuracy/precision of the procedure. • Explanations for the presence of the contaminant in the samples are presented. • Other sources originating from erroneous burning of dangerous products suspected. -- Abstract: The alleged use of potassium bromate (KBrO{sub 3}) in bread baking led a few authors to report on the chemical methods for the determination of KBrO{sub 3} levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about −16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.

  8. PIXE analysis of Nigerian flour and bread samples

    International Nuclear Information System (INIS)

    Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.

    2014-01-01

    Highlights: • The PIXE technique has been used to determine K and Br in a major Nigerian food item. • Samples were analysed using two proton beam energies, namely 1.25 MeV and 2.15 MeV. • Mismatched Ca results reflect its nature and accuracy/precision of the procedure. • Explanations for the presence of the contaminant in the samples are presented. • Other sources originating from erroneous burning of dangerous products suspected. -- Abstract: The alleged use of potassium bromate (KBrO 3 ) in bread baking led a few authors to report on the chemical methods for the determination of KBrO 3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about −16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples

  9. A βPIX-PAK2 complex confers protection against Scrib-dependent and cadherin-mediated apoptosis

    DEFF Research Database (Denmark)

    Frank, Scott R; Bell, Jennifer H; Frödin, Morten

    2012-01-01

    During epithelial morphogenesis, a complex comprising the βPIX (PAK-interacting exchange factor β) and class I PAKs (p21-activated kinases) is recruited to adherens junctions. Scrib, the mammalian ortholog of the Drosophila polarity determinant and tumor suppressor Scribble, binds βPIX directly. ...

  10. Development of a sample chamber for micro-PIXE

    International Nuclear Information System (INIS)

    Kurosawa, M.; Sueno, S.; Shima, K.; Ohshima, H.; Ishii, H.; Kamiya, H.; Kimoto, S.

    1997-01-01

    A new sample chamber for micro-PIXE analysis of geological thick samples has been successfully developed. A target in the sample chamber is normal to the beam and Si(Li) detectors are located at 135deg to the beam direction. For the sample observation, a normal viewing optics with the optical axis collinear with the beam is achieved by a combination of long working distance microscope and mirror with a central hole for the beam transmission. The normal incidence beam and normal viewing are essential to raise a spatial resolution of the thick target analysis. In addition, the sample chamber has fulfilled ten requirements as for material, driving stage, X-ray absorbers, space for another detector, etc. The information obtained by the development can give a new guide to manufacture the sample chamber for the micro-PIXE. (author)

  11. Analysis of trace elements in opal using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Ruth, E-mail: ruth.hinrichs@ufrgs.br [Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Bertol, A.P.L. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Instituto de Física, UFRGS, Porto Alegre, RS (Brazil)

    2015-11-15

    Particle induced X-ray emission (PIXE) analysis is particularly important for the analysis of trace elements of precious samples, being one of the few methods to determine elements with ppm concentration that does not affect sample integrity. A PIXE methodology for trace element analysis in opal was developed. To avoid detector count saturation due to the high number of Si-Kα X-rays generated in the sample, several filters were employed to optimize the reduction of the Si-Kα signal, while maintaining acceptable intensities of the other relevant X-ray lines. Two proton beam energies were tested, to establish the signal to noise ratio in different X-ray energies. Spectra were fitted with the software GUPIX, using a matrix composition determined with electron beam excited energy dispersive X-ray spectrometry. Above the energy of the silicon X-ray, several trace elements were quantified.

  12. Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, Z.Q.; Xia, H.N.; Jiang, J.C.; Yang, F.J.

    2002-01-01

    This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed

  13. Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE

    Science.gov (United States)

    Cheng, H. S.; Zhang, Z. Q.; Xia, H. N.; Jiang, J. C.; Yang, F. J.

    2002-05-01

    This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed.

  14. Mapping of heavy metals accumulated in plants using submilli-pixe camera

    International Nuclear Information System (INIS)

    Watanabe, R.; Hara, J.; Inoue, C.; Chida, T.; Amartaivan, TS.; Matsuyama, S.; Yamazaki, H.; Ishii, K.

    2004-01-01

    Phytoremediation is a technology for remediation of contaminated soils. In this study, we used a submilli-PIXE camera to analyze plants and soils from a shooting range. Some heavy metals were rapidly and easily detected in these samples. Element dot-maps of the plant show Cu and Pb accumulated in the epidermis of subterranean stems and the venation of leaves. From these findings, it is possible to map the distribution of heavy metals and to detail their location in the plant, using the submilli-PIXE analysis is an effective tool for undertaking phytoremediation research. (author)

  15. Qualitative analysis of a powdered diamond sample by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Mabida, C.; Annegarn, H.J.; Renan, M.J.; Sellschop, J.P.F.

    The main purpose of this analysis was to determine whether nickel is present in diamond powder as a trace element. Particle induced X-ray emission (PIXE) showed unambiguously that nickel was present. Due to the convenience of PIXE in multielemental analysis, the investigations also include a number of other trace elements in the sample

  16. PIXE analysis of tree leaves as a possible comparative integral monitor of particulates in urban areas

    International Nuclear Information System (INIS)

    Zucchiati, A.; Annegarm, H.J.; Chisci, R.

    1988-01-01

    The possibility of obtaing integral comparative data for particulate distribution in urban areas from PIXE analysis of tree leaves is discussed in relation to the leaf gross anatomy, to the diffusion of selected tree species in such areas and to the implementation of experimental techniques necessary to make PIXE analysis effective. Multielemental scans were performed on a small set samples; results are compared to PIXE analysis of typical urban aerosols. The validity of the method and the criteria for yearly relative comparisons of different areas are discissed

  17. Applications of PIXE to studies in dental and mental healths

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Melbourne Univ., Austin; Ainsworth, T.

    1981-01-01

    The elemental composition of healthy and diseased teeth from 25 South Australian children have been determined using thick target PIXE analysis. Different dental hard tissues, namely enamel, dentine, cementum and the amelodentinal junction, were analysed independently. A number of elements, Na, Mg, Al, P, S, Cl, Ca, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr and Pb have been detected, and their concentrations measured. The concentrations of some of the elements were found to very considerable between: (a) healthy and diseases teeth, (b) teeth of the same type, and (c) different parts of the same tooth. Attemps have been made to correlate the concentrations of the various elements with the health of the teeth. In a pilot study, PIXE has also been applied for Pb analysis in the teeth of a few mentally retarded children. The teeth of all the children, with the exception of one who was suffering from Downe's syndrome, were found to contain appreciable amounts of lead. It is suggested that PIXE would provide a more convenient and accurate form of analysis than destructive chemical methods, for correlation Pb in children's teeth with their mental abilities. (orig.)

  18. Particle induced x-ray emission (PIXE) measurement of the Cd content in animal tissues

    International Nuclear Information System (INIS)

    Le Huong Quynh; Demeter, I.; Hollos-Nagy, K.; Szoekefalvi-Nagy, Z.

    1989-12-01

    Particle induced x-ray emission (PIXE) measurements were performed on thin samples prepared from different rabbit tissues, using 3 MeV proton beam for inducing x-rays from the animal tissues. This method is very sensitive and very small amounts of trace elements can be detected. Cadmium, one of the most toxic elements which can be concentrated in animal and human tissues due to environmental pollution, was detected with a limit of 0.7 ppm. The trace element concentrations obtained by PIXE were compared to those measured by atomic absorption spectrometry. PIXE method is proposed for routine analysis at the Veterinary and Food Investigating Service, Budapest, Hungary. (D.Gy.) 6 refs.; 3 figs

  19. Particle Induced X-ray Emission (PIXE) Approach for the Quantification of Thin Al Films

    International Nuclear Information System (INIS)

    Younes, G; Zahraman, K; Nsouli, B; Soueidan, M; Ferro, G

    2008-01-01

    Particle Induced X-ray Emission (PIXE) has been used as a fast and non-destructive technique for sensitive characterization of ultra thin Al films deposited by evaporation onto Si substrate. In this work the PIXE technique was optimized, using proton beam at different energies and different angles of incidence, for the characterization of ultra thin Al films (few nanometers) deposited onto Si substrate. The PIXE results showed that a proton beam of 300 keV under tilting angle of 80 degree permits an accurate determination of Al with high sensitivity within few minutes of acquisition time and a LOD of less than 0.2 nm. The LOD versus energy and tilting angle will be presented and discussed. (author)

  20. Uncertainties in elemental quantitative analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Paschoa, A.S.; Barros Leite, C.V.

    1979-01-01

    The effects of the degree of non-uniformity of the particle beam, matrix composition and matrix thickness in a quantitative elemental analysis by particle induced X-ray emission (PIXE) are discussed and a criterion to evaluate the resulting degree of uncertainty in the mass determination by this method is established. (Auth.)

  1. Total CMB analysis of streaker aerosol samples by PIXE, PIGE, beta- and optical-absorption analyses

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Przybylowicz, W.J.

    1993-01-01

    Multielemental analyses of aerosol samples are widely used in air pollution receptor modelling. Specifically, the chemical mass balance (CMB) model has become a powerful tool in urban air quality studies. Input data required for the CMB includes not only the traditional X-ray fluorescence (and hence PIXE) detected elements, but also total mass, organic and inorganic carbon, and other light elements including Mg, Na and F. The circular streaker sampler, in combination with PIXE analysis, has developed into a powerful tool for obtaining time-resolved, multielemental aerosol data. However, application in CMB modelling has been limited by the absence of total mass and complementary light element data. This study reports on progress in using techniques complementary to PIXE to obtain additional data from circular streaker samples, maintaining the nondestructive, instrumental approach inherent in PIXE: Beta-gauging using a 147 Pm source for total mass; optical absorption for inorganic carbon; and PIGE to measure the lighter elements. (orig.)

  2. PIXE study on absorption of arsenate and arsenite by arsenic hyperaccumulating fern (Pteris vittata)

    International Nuclear Information System (INIS)

    Yamazaki, H.; Ishii, K.; Matsuyama, S.

    2008-01-01

    Pytoremediation using an arsenic hyperaccumulator, Petris vittata L., has generated an increasing interest worldwide due to both environmentally sound and cost effectiveness. However the mechanism of arsenic accumulation by this fern is not clear at this time. This study examined the uptake of arsenate (As(V)) and arsenite (As(III)) by a hydroponic culture of Pteris vittata using both in-air submilli-PIXE for different parts of the fern and in-air micro-PIXE for the tissue cells. These PIXE analysis systems used 3 MeV proton beams from a 4.5-MV single-ended Dynamitron accelerator at Tohoku University, Japan. The fern took up both arsenate and arsenite from hydroponic solutions which were spiked with 50 mg of arsenic per litter. Final amount of arsenic accumulation in the fern is 1,500 mg per kg (wet weight) of the plant biomass in arsenite treatment and 1,100 mg per kg in arsenate treatment. Arsenic accumulation was not observed at the root parts of the ferns. The in-vivo mapping of elements by submilli-PIXE analyses on the fern laminas showed the arsenic accumulation in the edges of a pinna. The micro-PIXE analyses revealed arsenic maps homogeneously distributed in cells of the lamina, stem and rhizome of the fern. These results indicate that arsenic, both arsenate and arsenite in a contaminated medium are translocated quickly from roots to fronds of Pteris vittata, and distributes homogeneously into tissue cells of the fern laminas. (author)

  3. Possibilities and conditions of applying PIXE analysis with external proton beam

    International Nuclear Information System (INIS)

    Potocek, V.

    1989-01-01

    The technical and methodological prerequisites are summed up for the use of the PIXE method with an external proton beam. The method is suitable for the preliminary analysis of unknown samples prior to the choice of the best suited analytical method, for the nondestructive analysis of rare samples such as unique works of art, of small amounts of materials which are difficult to access, etc., as well as for calibration and comparing analyses. As for the operators the application of the PIXE method with external proton beam assumes the availability of accelerator operating time, minimization of the length of exposure of the targets, optimization of parameters of the exciting beam and automation of the whole process. Attention is also devoted to technical provisions and organization of laboratory work. The design is described of an analytical unit using the PIXE method with external proton beam, and it is stated that the Van de Graaff accelerator at the Institute of Nuclear Physics in Rez near Prague could be used for the purpose. (Z.M.). 6 refs

  4. Homogeneity study of an Fe impurity in unalloyed Zn using PIXE

    International Nuclear Information System (INIS)

    Gamaz, Faziah; Chaves, Carlos; Waetjen, Uwe

    1999-01-01

    We have studied the distribution of an Fe impurity in unalloyed Zn material along line scans in spots of 1 mm diameter each using PIXE. In order to achieve the necessary precision (1%) in the determination of this low Fe content (about 100 mg/kg), a sufficient counting rate of Fe X-rays is needed without overloading the counting electronics with Zn X-rays at the same time. Therefore, the development of our PIXE analysis system had to take into account: (a) optimising the thickness of a Ni absorber foil in order to selectively reduce the counting rate of Zn without adding an unproportionally high Ni counting rate, (b) implementing a triggered ion beam deflection system capable of handling very high counting rates (up to 8 kcps), (c) developing the spectrum evaluation code to take account of the selective absorption by the Ni foil. The results of our PIXE measurements showed an inhomogeneity in Fe of up to 10%, considered too high to accept this zinc material as a new reference material

  5. PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael

    2013-10-01

    We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.

  6. Characterization of ceramics from the archaeological site of San Miguel Ixtapan, Mexico State, Mexico, using NAA, SEM, XRD and PIXE techniques

    International Nuclear Information System (INIS)

    Tenorio, D.; Monroy-Guzman, F.; Longoria, L.C.; Almazan-Torres, M.G.; Universidad Autonoma del Estado de Mexico, Toluca; Rodriguez-Garcia, N.L.

    2005-01-01

    Ceramic samples found in San Miguel Ixtapan, Mexico State, Mexico, were analyzed by means of NAA, PIXE, SEM and XRD. Statistical treatments such as bivariate cluster and principal-components analysis were applied to the data set. The origins of these ceramic samples were classified as local, regional and foreign. (author)

  7. Calibration of a PIXE system for analysis of environmental aerosols; Calibracion de un sistema PIXE para analisis de aerosoles ambientales

    Energy Technology Data Exchange (ETDEWEB)

    Aldape, F; Diaz, R V; Anguiano, G; Flores M, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1991-04-15

    The results of the calibration of the PIXE system for analysis of environmental aerosols in the CNM is presented. The system was calibrated in order to lead to the project study of environmental aerosols using PIXE from the qualitative dimension to the quantitative one. Part of this work it was carried out in collaboration with the expert of the IAEA Dr. D. Crumpton. The calibration of the system it was achieved bombarding thin targets of well-known composition with protons of 2.5 MeV. Using this technique it was determined the absolute elementary concentration in samples of atmospheric aerosols. As an example the calculation of the lead concentration in one of them whose result was of 662 {+-} 49 ng m{sup -3} is presented. This value agrees with the measurements made in the Crocker Nuclear Lab of the UCD. Its are also discussed the reproducibility and precision of the used technique. (Author)

  8. Qualitative PIXE analysis of mineral elements in some phytopharmaceutic drugs

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Harangus, Livia; Gugiu, M; Iordan, Andreea; Ciortea, C.

    2002-01-01

    A large number of phytopharmaceutic drugs are being developed, due to positive effects in various diseases and to high tolerance by the organism. While their medicinally active compounds have been identified, little attention has been paid to their mineral micro- and trace elements. The mineral elements in the drug may have therapeutic or toxic effects which should be properly assessed. Nuclear and atomic methods allow sensitive multielement detection and we previously performed nuclear activation analysis of some Romanian drugs made by plants. Despite this method's high sensitivity, its use is limited by the availability of a nuclear reactor. Particle-induced X-ray emission (PIXE) provides an alternative, and here we examined its potential for the analysis of mineral elements in three commercial phytopharmaceutical preparations, namely, Liv52, Mentat, and Geriforte. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normally oriented and connected to a multichannel analyzer and to a computer; the drug pills were fixed at 45 angle with respect to the beam. In all drugs PIXE detected mineral elements with Z > 16 down to trace levels. Major elements included K, Ca, Fe, Cu, and Zn, and minor/trace amounts of S, Cl, Ti, Cr, Mn, Ni, Ga, Br, Rb, Sr, Hg, and As/Pb were detected. Some differences were seen between the three drugs. Although at trace levels Ga, As, Hg and Pb are not toxic, one should consider that their accumulation might be harmful and caution seems recommendable on long-term cure. Most of the other elements are known to exert a positive biological role, and both in major and trace levels they may contribute to the therapeutic action. Thus PIXE analysis of mineral elements in phytopharmaceutic drugs, even qualitative, is useful for evaluating the benefits and risks in the therapy. (authors)

  9. Application of PIXE analysis to investigation of plants cultivated with contaminated soil of Fukushima

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, K., E-mail: keizo.ishii@qse.tohoku.ac.jp [Research Center for Remediation Engineering of Living Environments Contaminated with Radioisotopes, Department of Quantum Science and Energy Engineering, Tohoku University, 6-6 Aza-Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan); Terakawa, A.; Matsuyama, S.; Ishizaki, A.; Arai, H.; Osada, N.; Sugai, H.; Takahashi, H. [Research Center for Remediation Engineering of Living Environments Contaminated with Radioisotopes, Department of Quantum Science and Energy Engineering, Tohoku University, 6-6 Aza-Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan); Sera, K. [Cyclotron Research Center, Iwate Medical University, 348-58 Tomegamori, Takizawa, Iwate 020-0173 (Japan); Sasaki, H.; Sasaki, K.; Sawamura, T. [Sasaki Taro memorial PIXE Center, Asano-cho 5, Hakodate 040-0076 (Japan)

    2014-08-01

    We present a method to research low radioactive cesium contaminated plants by the use of PIXE analysis. Highly contaminated regions still remain in the Fukushima prefecture. We collected wild plants growing in this area, that is, Butterbur, Welsh onion, Alpine leek and White clover and measured their specific activities of {sup 137}Cs and {sup 40}K. We also measured {sup 137}Cs and {sup 40}K specific activities of soil under these plants. Soil-to-plant transfer factors of {sup 137}Cs were ∼0.02 for 4 wild plants and those of {sup 40}K were ∼0.5 except for White clover. Using PIXE analysis, we measured the concentration of mineral elements in these plants. Among mineral elements, we noted the concentrations of additional alkali metal elements such as Na, K and Rb. The experimental results showed that the concentration of Rb was proportional to the specific activities of {sup 137}Cs except for Welsh onion and other elements had no strong correlation with {sup 137}Cs. These results indicate that there may be correlations between the adsorption of Cs and Rb.

  10. Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE

    International Nuclear Information System (INIS)

    Correa, R.; Chesta, M.A.; Morales, J.R.; Dinator, M.I.; Requena, I.; Vila, I.

    2006-01-01

    An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses

  11. Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Correa, R. [Universidad Tecnologica Metropolitana, Departamento de Fisica, Av. Jose Pedro Alessandri 1242, Nunoa, Santiago (Chile)]. E-mail: rcorrea@utem.cl; Chesta, M.A. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Medina Allende s/n Ciudad Universitaria, 5000 Cordoba (Argentina)]. E-mail: chesta@famaf.unc.edu.ar; Morales, J.R. [Universidad de Chile, Facultad de Ciencias, Departamento de Fisica, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: rmorales@uchile.cl; Dinator, M.I. [Universidad de Chile, Facultad de Ciencias, Departamento de Fisica, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: mdinator@uchile.cl; Requena, I. [Universidad de Granada, Departamento de Ciencias de la Computacion e Inteligencia Artificial, Daniel Saucedo Aranda s/n, 18071 Granada (Spain)]. E-mail: requena@decsai.ugr.es; Vila, I. [Universidad de Chile, Facultad de Ciencias, Departamento de Ecologia, Las Palmeras 3425, Nunoa, Santiago (Chile)]. E-mail: limnolog@uchile.cl

    2006-08-15

    An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses.

  12. PIXE as a characterization technique in the cutting tool industry

    International Nuclear Information System (INIS)

    Freemantle, C.S.; Sacks, N.; Topic, M.; Pineda-Vargas, C.A.

    2014-01-01

    Two WC–Co powders have been analyzed using micro-PIXE to identify elemental concentration and distribution. A powder recycled primarily from used mining components and a powder produced exclusively from fresh raw materials was studied. Elemental mapping of major elements as well as impurities, within powder granule cross sections, was performed. Contaminants (e.g. Fe and Ni) from manufacturing processes, as well as trace impurities (e.g. Cr, Cl, Ca and S) from recycling were detected, quantified and compared. The extent of increased concentrations of impurities resulting from recycling were observed, demonstrating the potential for PIXE as a characterization tool for detecting trace elements in cemented carbides, allowing for future improvements in the manufacturing and recycling processes

  13. PIXE as a characterization technique in the cutting tool industry

    Energy Technology Data Exchange (ETDEWEB)

    Freemantle, C.S., E-mail: chris@freemantle.co.za [School of Chemical and Metallurgical Engineering and DST/NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, P/Bag 3, Wits 2050 (South Africa); Pilot Tools (Pty) (Ltd.), P.O. Box 27559, Benrose 2011 (South Africa); Sacks, N. [School of Chemical and Metallurgical Engineering and DST/NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, P/Bag 3, Wits 2050 (South Africa); Topic, M. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Pineda-Vargas, C.A. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Faculty of Health and Wellness Sciences, CPUT, Bellville (South Africa)

    2014-01-01

    Two WC–Co powders have been analyzed using micro-PIXE to identify elemental concentration and distribution. A powder recycled primarily from used mining components and a powder produced exclusively from fresh raw materials was studied. Elemental mapping of major elements as well as impurities, within powder granule cross sections, was performed. Contaminants (e.g. Fe and Ni) from manufacturing processes, as well as trace impurities (e.g. Cr, Cl, Ca and S) from recycling were detected, quantified and compared. The extent of increased concentrations of impurities resulting from recycling were observed, demonstrating the potential for PIXE as a characterization tool for detecting trace elements in cemented carbides, allowing for future improvements in the manufacturing and recycling processes.

  14. Examination of the regional distribution of minor and trace elements in normal human brain by PIXE and chemometric techniques

    International Nuclear Information System (INIS)

    Maenhaut, W.; Hebbrecht, G.; Reuck, J. de

    1993-01-01

    Particle-induced X-ray emission (PIXE) was used to measure two minor and six trace elements, i.e. K, Ca, Mn, Fe, Cu, Zn, Se, and Rb, in up to 50 different structures (regions) of brains from Belgian individuals without neurological disorders. The data matrix with the mean dry-weight elemental concentrations and mean wet-to-dry weight ratio (means over 18 brains) for the various structures was subjected to two chemometric techniques, i.e., VARIMAX rotated absolute principal component analysis (APCA) and hierarchical cluster analysis. Three components were identified by APCA: Components 1 and 3 represented aqueous fractions of the brain (respectively the intracellular and extracellular fluid), whereas component 2 apparently represented the solid brain fraction. The elements K, Cu, Zn, Se, and Rb were predominantly attributed to component 1, Ca to component 3, and Fe to component 2. In the hierarchical cluster analysis seven different agglomerative cluster strategies were compared. The dendrograms obtained from the furthest neighbor and Ward's error sum strategy were virtually identical, and they consisted of two large clusters with 30 and 16 structures, respectively. The first cluster included all gray matter structures, while the second comprised all white matter. Furthermore, structures involved in the same physiological function or morphologically similar regions often conglomerated in one subcluster. This strongly suggests that there is some relationship between the trace element profile of a brain structure and its function. (orig.)

  15. {mu}PIXE for a {mu}Brain: The vinegar fly's brain, antenna, sensilla hairs and eye ion concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Reinert, Anja, E-mail: areinert@ice.mpg.de [Department of Evolutionary Neuroethology, Max Planck Institute for Chemical Ecology, Hans-Knoell-Strasse 8, 07745 Jena (Germany); Barapatre, Nirav [Institute for Experimental Physics II, University of Leipzig, Linnestrasse 5, 04103 Leipzig (Germany); Sachse, Silke [Department of Evolutionary Neuroethology, Max Planck Institute for Chemical Ecology, Hans-Knoell-Strasse 8, 07745 Jena (Germany); Reinert, Tilo [Department of Physics, University of North Texas, 1155 Union Circle, 76203 Denton, TX (United States)

    2011-10-15

    The vinegar fly Drosophila melanogaster is used as model organism to study a variety of different scientific purposes. Thus, our laboratory studies the olfactory system by neurobiological experiments. These techniques are often disruptive and need to compensate or exchange the body fluid, the lymph, with an artificial Ringer's solution in defined compartments of the fly. The solution mainly contains Na, Cl, K and Ca and is to keep physiological conditions. Therefore, the knowledge about the ion concentrations in the respective Drosophila lymph is required for a correct mixture of the ions. This paper presents the spatially resolved concentrations of P, S, Cl, K, Ca, Fe, Cu and Zn in lyophilised head cryosections of Drosophila by using quantitative {mu}PIXE at the ion beam facility LIPSION in Leipzig. The PIXE maps enable a detailed analysis of particular regions of interest down to a spatial resolution of 0.5 {mu}m. We quantified the ion concentrations especially in the brain, the antenna and its sensilla hairs acting as the olfactory organ of the fly, in the compound eye and in the mouthparts. The averaged element concentrations of these main compartments are (in descending order): P: 90 mM, K: 81 mM, S: 38 mM, Cl: 18 mM, Ca: 4.9 mM, Fe: 1.4 mM, Zn: 1.2 mM, Cu: 0.06 mM. Certain structures or cavities possess a remarkably high concentration of particular elements and might reflect the different functions of the compartments. An example presented in more detail is the composition of the compound eye. Conclusively, our findings on the ion concentrations might be useful for the mixture of the Drosophila Ringer's solution to ensure physiological conditions in experiments.

  16. GridPix detectors – introduction and applications

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, J., E-mail: kaminski@physik.uni-bonn.de; Bilevych, Y.; Desch, K.; Krieger, C.; Lupberger, M.

    2017-02-11

    GridPix detectors are a new kind of detectors combining a high density pixelized readout ASIC with a Micromegas gas amplification stage. Because of the alignment of mesh holes and pixels, a high efficiency for detecting and separating single primary electrons is reached. This feature leads to excellent spatial and energy resolutions as demonstrated by several different setups.

  17. Application of the proton induced X-ray emission (PIXE) technique to the study of problems in forensic science

    International Nuclear Information System (INIS)

    Sen, S.; Varier, K.M.; Mehta, G.K.; Sen, P.; Panigrahi, N.

    1981-01-01

    The PIXE technique has been successfully applied to study crime related problems in forensic science. The experimental arrangements and various practical problems involved are discussed. Consistency and reproducibility checks are presented. The results from the gun-shot residue profiles of the associated elements about the bullet hole obtained for various firing distances showed that the sensitivity of the PIXE technique could play a vital role in forensic science in assigning the distance from the gun to the victim and identifying the type of bullet used. PIXE runs on other forensic related specimens demonstrate its usefulness in indetification and evaluation of vital parameters related to a crime. The reliability and the importance of the PIXE method in solving criminal and related problems in forensic science are discussed. (orig.)

  18. Evaluation of the applicability of the MOUDI impactor for aerosol collections with subsequent multielement analysis by PIXE

    International Nuclear Information System (INIS)

    Maenhaut, W.; Ducastel, G.; Hillamo, R.E.; Pakkanen, T.A.

    1993-01-01

    The micro-orifice uniform deposit impactor (MOUDI) is an 8-stage impactor with cut-sizes down to 0.056 μm and which allegedly provides uniform aerosol deposits for the various stages. In the present study it was examined how uniform the aerosol deposits really are for each impaction plate, and whether the uniformity is sufficient for a straightforward PIXE analysis. This was done by collecting several samples of ambient aerosol with the MOUDI and by determining the deposition pattern of various elements on the foils through a linear PIXE scan across each impaction foil. It was found that the deposits are far from uniform at the millimeter level for the stage numbers up to 6. Despite this, concentration data can easily be obtained by PIXE from such samples, provided that the analyzed area is carefully selected and appropriate correction factors for the nonuniformity are employed. Some size distribution data are presented. A comparison is also made of the size distribution data and detection limits that result from employing the MOUDI in combination with PIXE with those obtainable by PIXE analysis of some other types of cascade impactors. (orig.)

  19. Simultaneous PIXE and PIGE analyses of aerosol samples collected in urban areas

    International Nuclear Information System (INIS)

    Boni, C.; Caruso, E.; Cereda, E.; Marcazzan, G.M.; Redaelli, P.; Bacci, P.

    1988-01-01

    The paper concerns the simultaneous PIXE (Particle Induced X-ray Emission) and PIGE (Proton Induced Gamma-ray Emission) analyses of aerosol samples collected in urban areas. The results show that PIGE can detect Li, F, Na, Al, and Si in fly ashes and F, Na, Al and Si in atmospheric aerosol. The PIXE-PIGE technique has also been applied to 80 samples of atmospheric particular matter collected above Milan during the winter and summer months of 1986/7, and the average values of concentrations and enrichment factors are given for the detected elements. (U.K.)

  20. Elemental analysis of gold coins by particle induced X-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Ferreira, G.P.; Gil, F.B.

    1981-01-01

    A Van de Graaff accelerator of 2 MeV energy was used for quantitative analysis of gold coins of the eighteenth and nineteenth centuries by the PIXE method. The results reproduce well the known legal title of the coins. However, for confirmation, a small set of Au-Ag-Cu and Au-Cu standards was also analysed. Again, the known composition of the standards was reasonably reproduced. In this way the authors think that the PIXE method is quite adequate for absolutely non-destructive analysis of gold alloy artifacts with no need of standards. (author)

  1. Deep PIXE: finding diamonds with the proton microprobe

    International Nuclear Information System (INIS)

    Griffin, W.L.; Ryan, C.G.

    1991-01-01

    Since 1987 the CSIRO Div. of Exploration Geoscience has carried out a program of proton-microprobe (PIXE) analysis aimed at using trace-element data on indicator minerals to discriminate between those from diamondiferous and barren source rocks. The results have provided both important new tools for the exploration industry, and significant new information on the conditions and processes of diamond growth. Cr-pyrope garnet has been used as Ni thermometer while chromites, in partcular their Zn content, has allowed correlation of chromite composition with temperature. The two techniques described provide a significant increase in exploration efficiency, through early recognition and rejection of barren targets and concentration of resources on more promising targets. They also provide direct cost savings in evaluation of ore bodies once they are found. It is estimated that evaluation of a prospect by conventional bulk testing is expensive ($100-500K) and time-consuming; an evaluation by PIXE methods is done quickly for a tiny fraction of that cost. 1 refs., 4 figs

  2. PIXE analysis of nephrite minerals from different deposits

    Science.gov (United States)

    Zhang, Z. W.; Gan, F. X.; Cheng, H. S.

    2011-02-01

    External-beam PIXE was used to determine the major, minor and trace elements of 45 nephrite minerals from 14 different deposits, including China and other countries. Depending on the R∗ value (mole percent of Mg 2+/(Mg 2+ + Fe 2+(3+))) and content of Cr, Co and Ni, two types of nephrite minerals from dolomite and serpentinized ultramafic deposits can be more accurately distinguished. Besides, the nephrite minerals from Xiaomeiling and Wenchuan deposit can be distinguished with others from dolomite deposits, through the content of Sr and Mn/Fe value, respectively. Moreover, depending on the Sr content, clear evidence was given to prove that the raw materials of ancient nephrite artifacts from Liangzhu culture ruins are not from Xiaomeiling nephrite deposit. Furthermore, PIXE as a non-destructive method will be more used to study ancient nephrite artifacts, so these results can provide scientific basis for seeking the provenance of nephrite raw materials.

  3. PIXE-PIGE analysis of some Indian medicinal plants

    Science.gov (United States)

    Nomita Devi, K.; Nandakumar Sarma, H.

    2010-06-01

    The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton induced X-ray emission (PIXE) and proton induced γ-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in varying concentrations in the studied medicinal plants and no toxic heavy metals were detected. The concentration of the various elements in the medicinal plants and their role in treating various diseases are discussed.

  4. PIXE-PIGE analysis of some Indian medicinal plants

    Energy Technology Data Exchange (ETDEWEB)

    Nomita Devi, K., E-mail: nomita_k@rediffmail.co [Department of Physics, Manipur University, Canchipur, Imphal 795003 (India); Nandakumar Sarma, H. [Department of Physics, Manipur University, Canchipur, Imphal 795003 (India)

    2010-06-15

    The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton induced X-ray emission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in varying concentrations in the studied medicinal plants and no toxic heavy metals were detected. The concentration of the various elements in the medicinal plants and their role in treating various diseases are discussed.

  5. PIXE analysis of atmospheric aerosol and hydrometeor particles

    International Nuclear Information System (INIS)

    Groeneveld, K.O.; Hofmann, D.; Georgii, H.W.

    1993-01-01

    Atmospheric aerosol and hydrometeor particles act decisively on our weather, climate and thereby on all living conditions on Earth. Particle induced X-ray emission (PIXE) analysis has been demonstrated to be an extremely valuable tool for quantitative and qualitative elemental analysis of aerosol particles and hydrometeors. Reliability and detection limits of PIXE are determined, including comparison with other techniques. Aerosol particles are collected on a global scale in ground stations, or by ships and by planes. Correlation between wind direction and elemental composition of atmospheric aerosols, elemental particle size distributions of the tropospheric aerosol, aerosol elemental composition in particle size fractions in the case of long range transport, transport pathways of pollution aerosol, and trace element content precipitation are discussed. Hydrometeors were studied in the form of rain, snow, fog, dew and frost. The time dependence of the melting process of snow was studied in detail, in particular the washout phenomena of impurity ions. (orig.)

  6. PIXE analysis of Nigerian flour and bread samples

    Science.gov (United States)

    Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.

    2014-01-01

    The alleged use of potassium bromate (KBrO3) in bread baking led a few authors to report on the chemical methods for the determination of KBrO3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about -16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.

  7. Monitoring of exposure to selected metals in workers of a ferroalloy production plant using NAA and PIXE

    International Nuclear Information System (INIS)

    Kucera, J.; Havranek, V.; Hnatowicz, V.; Bencko, V.; Fabianova, E.; Sysalova, J.

    1998-01-01

    Advantages and pitfalls of direct and biological monitoring of occupational exposure are briefly mentioned and a project aimed at evaluating exposure to chromium (and possibly manganese) in workers of a ferro-alloy production plant using both the above approaches is outlined. Facilities for NAA and PIXE at the Nuclear Physics Institute at Rez to be used in the project are described. Results of quality assurance of INAA method for analysis of workplace air born particulate matter and blood sampling are presented. Results from previous work relating to this Co-ordinated Research Programme - studying exposure of workers of a vanadium pentoxide production plant are also briefly reviewed. (author)

  8. PIXE studies on teeth

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Ainsworth, T.

    1980-01-01

    The elemental composition of healthy and diseased teeth from 25 children has been determined using thick-target proton induced x-ray emission, (PIXE), analysis. Various dental hard tissues: enamel, dentine and cementum, and their junctions, as well as different parts of the same tissue, have been examined individually. A number of elements: Na, Mg, Al, P, S, Cl, Ca, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr and Pb, has been determined in these dental tissues. The concentrations of some of the elements tend to vary considerably from tooth to tooth and tissue to tissue. Attempts have been made to correlate the concentrations of various elements in teeth with their health

  9. pix-1 controls early elongation in parallel with mel-11 and let-502 in Caenorhabditis elegans.

    Science.gov (United States)

    Martin, Emmanuel; Harel, Sharon; Nkengfac, Bernard; Hamiche, Karim; Neault, Mathieu; Jenna, Sarah

    2014-01-01

    Cell shape changes are crucial for metazoan development. During Caenorhabditis elegans embryogenesis, epidermal cell shape changes transform ovoid embryos into vermiform larvae. This process is divided into two phases: early and late elongation. Early elongation involves the contraction of filamentous actin bundles by phosphorylated non-muscle myosin in a subset of epidermal (hypodermal) cells. The genes controlling early elongation are associated with two parallel pathways. The first one involves the rho-1/RHOA-specific effector let-502/Rho-kinase and mel-11/myosin phosphatase regulatory subunit. The second pathway involves the CDC42/RAC-specific effector pak-1. Late elongation is driven by mechanotransduction in ventral and dorsal hypodermal cells in response to body-wall muscle contractions, and involves the CDC42/RAC-specific Guanine-nucleotide Exchange Factor (GEF) pix-1, the GTPase ced-10/RAC and pak-1. In this study, pix-1 is shown to control early elongation in parallel with let-502/mel-11, as previously shown for pak-1. We show that pix-1, pak-1 and let-502 control the rate of elongation, and the antero-posterior morphology of the embryos. In particular, pix-1 and pak-1 are shown to control head, but not tail width, while let-502 controls both head and tail width. This suggests that let-502 function is required throughout the antero-posterior axis of the embryo during early elongation, while pix-1/pak-1 function may be mostly required in the anterior part of the embryo. Supporting this hypothesis we show that low pix-1 expression level in the dorsal-posterior hypodermal cells is required to ensure high elongation rate during early elongation.

  10. Comparative experimental study of PIXE and X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Vega B, L.R. De la.

    1994-01-01

    PIXE and X RF techniques are powerful analysis instruments in the determination of traces of elements. Although the physical processes characteristic X-rays production (ionization-emission) are similar in both methods, the representative background of each technique, responsible of its sensitivity, are different. This is because the interaction between exciter agents and the matter produces different effects. In PIXE, the background is caused by the radiation produced by the braking of the secondary electrons: Bremsstrahlung. In X RF, the background is due to the elastic and inelastic scattering of photons: Rayleigh and Compton effects. In this work, we have compared the results of the analysis of environmental samples using both methods, in order to know the scope of each one and develop them as complementary techniques. (Author)

  11. PIXE study on arsenic accumulation by a fern. Pteris vittata

    International Nuclear Information System (INIS)

    Yamazaki, H.; Ishii, K.; Matsuyama, S.

    2010-01-01

    Pteris vittata is a fern reported to be an arsenic hyper-accumulator. To develop the practical application of the fern to a phytoremediation technique, it is necessary to explicate the effective accumulation mechanism. In this study, the arsenic distribution and the elemental correlation in the cellular level were examined in the fronds supplied with arsenate and arsenite separately via xylem vessel using an in-air micro-PIXE system at Tohoku University. The difference in transportation rate between arsenate and arsenite as well as the translocation of elements necessary for plant metabolism was revealed in different tissues of the fronds accumulating arsenic in high concentration. Hence, the in-air micro-PIXE analysis is an effective measure for undertaking phytoremediation research of hyper-accumulator plants. (author)

  12. Improvement in the determination of elemental concentrations in PIXE analyses using artificial neural system

    International Nuclear Information System (INIS)

    Correa, R.; Dinator, M.I.; Morales, J.R.; Miranda, P.A.; Cancino, S.A.; Vila, I.; Requena, I.

    2008-01-01

    An Artificial Neural System, ANS, has been designed to operate in the analysis of spectra obtained from a PIXE (Proton Induced X-ray Emissions) application. The special designed ANS was used in the calculation of the concentrations of the major elements in the samples. Neural systems using several feed-forward ANN of similar topology working in parallel were trained with error back propagation algorithm using sets of spectra of known elemental concentrations. Following the training phase of the neural networks, other PIXE spectra were analyzed with this methodology providing unknown elemental concentrations. ANS results were compared with results obtained by traditional computer codes like AXIL and GUPIX, obtaining correlations factors close to one. The rather short time required to process each spectrum, of the order of microseconds, allows fast analysis of a large number of samples. Here we present applications of ANS in the PIXE analyses of samples of organic nature like liver, gills and muscle from fishes. ANS results were compared with elemental concentrations obtained in a previous application where a single ANN was used for each analyzed element. PIXE analyses were performed at the Nuclear Physics Laboratory of the University of Chile, using 2.2 MeV proton beams provided by a Van de Graaff accelerator. (author)

  13. Towards truly simultaneous PIXE and RBS analysis of layered objects in cultural heritage

    International Nuclear Information System (INIS)

    Pascual-Izarra, Carlos; Barradas, Nuno P.; Reis, Miguel A.; Jeynes, Chris; Menu, Michel; Lavedrine, Bertrand; Ezrati, Jean Jacques; Roehrs, Stefan

    2007-01-01

    For a long time, RBS and PIXE techniques have been used in the field of cultural heritage. Although the complementarity of both techniques has long been acknowledged, its full potential has not been yet developed due to the lack of general purpose software tools for analysing the data from both techniques in a coherent way. In this work we provide an example of how the recent addition of PIXE to the set of techniques supported by the DataFurnace code can significantly change this situation. We present a case in which a non homogeneous sample (an oxidized metal from a photographic plate - heliography - made by Niepce in 1827) is analysed using RBS and PIXE in a straightforward and powerful way that can only be performed with a code that treats both techniques simultaneously as a part of one single and coherent analysis. The optimization capabilities of DataFurnace, allowed us to obtain the composition profiles for these samples in a very simple way

  14. Detection and quantitative determination by PIXE of the mutagen Sn2+ in yeast cells

    International Nuclear Information System (INIS)

    Viau, C.M.; Yoneama, M.-L.; Dias, J.F.; Pungartnik, C.; Brendel, M.; Henriques, J.A.P.

    2006-01-01

    The main goal of this work was to determine the concentration of Sn 2+ ions in cells of the yeast Saccharomyces cerevisiae and to correlate their quantity with the genotoxicity of intracellularly accumulated metal ions. The intracellular metal content of yeast cells was determined by PIXE (particle-induced X-ray emission) after cell exposure to SnCl 2 . To that end, a thick target protocol was developed for PIXE analysis. The samples were irradiated with a 2 MeV proton beam, while the induced X-rays were detected with a high-purity germanium detector. The results of the toxicity of SnCl 2 and the PIXE analysis performed with two different yeast strains (haploid and diploid) suggest that the exposure of haploid and diploid yeast to Sn 2+ induces DNA lesions and that the absorption depends on the genetic background of each strain

  15. K, L, and M shell datasets for PIXE spectrum fitting and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, David D., E-mail: dcz@ansto.gov.au; Crawford, Jagoda; Siegele, Rainer

    2015-11-15

    Highlights: • Differences between several datasets commonly used by PIXE codes for spectrum fitting and concentration estimates have been highlighted. • A preferred option dataset was selected which includes ionisation cross sections, fluorescence yield, Coster–Kronig probabilities and X-ray line emission rates for K, L and M subshells. • For PIXE codes differences of several tens of percent can be seen for selected elements for L and M lines depending on the data sets selected. - Abstract: Routine PIXE analysis programs, like GUPIX, GEOPIXE and PIXAN generally perform at least two key functions firstly, the fitting of K, L and M characteristic lines X-ray lines to a background, including unfolding of overlapping lines and secondly, the use of a fitted primary Kα, Lα or Mα line area to determine the elemental concentration in a given matrix. To achieve these two results to better than 3–5% the data sets for fluorescence yields, emission rates, Coster–Kronig transitions and ionisation cross sections should be determined to better than 3%. There are many different theoretical and experimental K, L and M datasets for these parameters. How they are applied and used in analysis programs can vary the results obtained for both fitting and concentration determinations. Here we discuss several commonly used datasets for fluorescence yields, emission rates, Coster–Kronig transitions and ionisation cross sections for K, L and M subshells and suggests an optimum set to obtain consistent results for PIXE analyses across a range of elements with atomic numbers from 5 ⩽ Z ⩽ 100.

  16. Obsidians from the Kerkennah Islands (eastern Tunisia) and the PIXE elemental compositions of the Mediterranean peralkaline obsidians

    International Nuclear Information System (INIS)

    Le Bourdonnec, François-Xavier; Poupeau, Gérard; Boussofara, Ridha

    2015-01-01

    The provenance of 37 obsidians from the Kerkennah Islands (central Mediterranean Sea) was determined by PIXE. It is shown that they came from the two main obsidian sources, Balata dei Turchi and Lago di Venere, of the Pantelleria Island. A comparison of the PIXE elemental composition of geological vs. archaeological obsidians of central and western Mediterranean shows that their sources present elemental compositions homogeneous enough to make possible sourcing studies. However, a comparison between the distributions of geological and archaeological obsidians chemistry shows that the PIXE source qualifications do not cover yet the whole of their internal variations

  17. Obsidians from the Kerkennah Islands (eastern Tunisia) and the PIXE elemental compositions of the Mediterranean peralkaline obsidians

    Energy Technology Data Exchange (ETDEWEB)

    Le Bourdonnec, François-Xavier, E-mail: Francois-Xavier.Le-Bourdonnec@u-bordeaux-montaigne.fr [Institut de Recherche sur les Archéomatériaux (IRAMAT), Centre de Recherche en Physique Appliquée à l’Archéologie (CRP2A), UMR 5060, CNRS-Université Bordeaux Montaigne, Maison de l’Archéologie, Esplanade des Antilles, 33607 Pessac Cédex (France); Poupeau, Gérard [Institut de Recherche sur les Archéomatériaux (IRAMAT), Centre de Recherche en Physique Appliquée à l’Archéologie (CRP2A), UMR 5060, CNRS-Université Bordeaux Montaigne, Maison de l’Archéologie, Esplanade des Antilles, 33607 Pessac Cédex (France); UMR 7194 CNRS et Département de Préhistoire du Muséum National d’Histoire Naturelle, Place du Trocadéro, 75016 Paris (France); Boussofara, Ridha, E-mail: ridha57@yahoo.fr [The National Heritage Institute, 4 Place du Château, 1008 Tunis (Tunisia); and others

    2015-09-01

    The provenance of 37 obsidians from the Kerkennah Islands (central Mediterranean Sea) was determined by PIXE. It is shown that they came from the two main obsidian sources, Balata dei Turchi and Lago di Venere, of the Pantelleria Island. A comparison of the PIXE elemental composition of geological vs. archaeological obsidians of central and western Mediterranean shows that their sources present elemental compositions homogeneous enough to make possible sourcing studies. However, a comparison between the distributions of geological and archaeological obsidians chemistry shows that the PIXE source qualifications do not cover yet the whole of their internal variations.

  18. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    Energy Technology Data Exchange (ETDEWEB)

    Migliori, A. [Dipartimento di Fisica dell' Universita and Istituto Nazionale di Fisica Nucleare, Firenze, Via G. Sansone 1, 50019 Sesto Fiorentino (Firenze) (Italy)], E-mail: migliori@fi.infn.it; Grassi, N.; Mando, P.A. [Dipartimento di Fisica dell' Universita and Istituto Nazionale di Fisica Nucleare, Firenze, Via G. Sansone 1, 50019 Sesto Fiorentino (Firenze) (Italy)

    2008-05-15

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 {mu}m size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness.

  19. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    International Nuclear Information System (INIS)

    Migliori, A.; Grassi, N.; Mando, P.A.

    2008-01-01

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 μm size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness

  20. Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis

    Science.gov (United States)

    Migliori, A.; Grassi, N.; Mandò, P. A.

    2008-05-01

    In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 μm size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness.

  1. Analysis of micro matter reference materials of lichen and algae by SRXRF and PIXE

    International Nuclear Information System (INIS)

    Yin Sha Xin; Wang Jian Liu; Zhang Peiqun

    2002-01-01

    In the present work two nuclear micro analysis techniques, synchrotron radiation (SRXRF) and macro proton induced X ray emission (macro PIXE), were used in the homogeneity test of Algae IAEA-413 and Lichen IAEA-338, and the certification of their elemental contents too. Finally, the Ingamell's sampling constant Ks and the relative homogeneity factor HE of some elements in these two RMs were estimated on the base of our macro PIXE results. (author)

  2. Scanning transmission ion microscopy on Fudan SPM facility

    International Nuclear Information System (INIS)

    Li Yongqiang; Shen Hao; Zheng Yi; Li Xinyi; Liu Bo; Satoh Takahiro

    2011-01-01

    In this paper, we report a novel measurement system based on the development of Fudan Scanning Proton Microscopy (SPM) facility. By using Si-PIN diode(Hamamatsu S1223-01) detector, scanning transmission ion microscopy (STIM) measurement system has been set up. It can provide density and structural images with high probing efficiency and non-destruction by utilizing the energy loss of high energy (MeV) and focused ions penetrating through a thin sample. STIM measurement is able to map the density distribution of organic elements which mostly compose biology materials, such information can not be detected by using conventional Be-windowed Si (Li) X-ray detector in Particle Induced X-ray Emission (PIXE) technique. The spatial resolution capability of STIM is higher than PIXE technique at same accelerator status. As a result of STIM measurement, Paramecium attached on the top of Kapton tube was measured by STIM. (authors)

  3. Non linear-least-squares fitting for pixe spectra

    International Nuclear Information System (INIS)

    Benamar, M.A.; Tchantchane, A.; Benouali, N.; Azbouche, A.; Tobbeche, S.

    1992-10-01

    An interactive computer program for the analysis of Pixe spectra is described. The fitting procedure consists of computing a function which approximates the experimental data. A nonlinear least-squares fitting is used to determine the parameters of the fit. The program takes into account the low energy tail and the escape peaks

  4. Wavelength dispersive μPIXE setup for the ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Fazinić, S., E-mail: stjepko.fazinic@irb.hr [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Božičević Mihalić, I.; Tadić, T.; Cosic, D.; Jakšić, M. [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Mudronja, D. [Croatian Conservation Institute, Grškovićeva 23, 10000 Zagreb (Croatia)

    2015-11-15

    We have developed a small wavelength dispersive X-ray spectrometer to explore the possibility of performing chemical speciation on microscopic samples utilizing focused ion beams available at the Rudjer Boskovic Institute ion microprobe. Although PIXE spectra are in principle chemically invariant, small influence of chemical effects could be observed even with Si(Li) or SDD detectors. Such chemical effects can be clearly seen with high resolution crystal X-ray spectrometers having energy resolution of several eV. A dedicated vacuum chamber, housing the diffraction crystal, sample holder and CCD X-ray detector, was constructed and positioned behind the main ion microprobe vacuum chamber. Here we will briefly describe the spectrometer, and illustrate its capabilities on measured K X-ray spectra of selected sulfur compounds. We will also demonstrate its abilities to resolve K and M X-ray lines irresolvable by solid state ED detectors usually used in PIXE.

  5. Particle induced X-ray emission (PIXE) present and future. Ryushisen reiki X sen bunsekiho (PIXE) no genjo to shorai

    Energy Technology Data Exchange (ETDEWEB)

    Uda, M. (Waseda Univ., Tokyo (Japan). Science and Engineering)

    1992-07-10

    The principle of measurement of PIXE are explained. It has in comparison with SEM and EPM, the following characteristics such as; very short measurement and analysis time, developed detection sensitivity for more than 100 elements, no need of pretreatment, undestructive analysis method in the air, possibility of trace element analysis by using micro specimen and information input of chemical bonding condition. Bio-medical applications have been, the microanalysis of multi elements in light element matrix forming living body and the diagnosis of kidney cancer and other diseases. Environmental applications have been, detection of the composition of sea water and the detection of the pollutants of the rivers by elements concentration distribution. It is also applied for managing the amount of impurities in electronic materials and monitoring the emitted elements from fusion reactor. It is used for archaeological analysis such as, analysis of gold fixing in ancient Rome and earthernware analysis of ancient China. As for the chemical bonding condition, the small difference of chemical bonding has been able to be observed clearly as a difference of strength over the multiple spectra, and PIXE has prospects in multiple fields. 24 refs., 21 figs.

  6. Trace elements in human, cattle and swine teeth, measured by external beam PIXE-PIGE setup

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Rizzutto, M.A.; Added, N.; Liguori Neto, R.; Acquadro, J.C.; Vilela, M.; Oliveira, T.R.C.F.; Markarian, R.A.; Mori, M.

    2001-01-01

    The use of animal teeth to replace human teeth in dentistry school classes and to test chemicals and fillings, motivated for a better characterization of the elementary composition of their enamel, since some of the chemical properties, adhesion and chemical compatibility may depend on these parameters. Cattle, swine and human teeth were collected by dentists of the University of Sao Paulo. These teeth came primarily from Sao Paulo region and were analyzed for trace elements at the Open Nuclear Physics Laboratory, using a high energy external proton beam, PIXE-PIGE setup

  7. PIXE - Analysis for environmental and biological samples

    International Nuclear Information System (INIS)

    Baptista, G.B.

    1980-04-01

    The usefulness and accuracy of PIXE as an analytical tool in the study of trace elements in environmental samples of the Brazilian Cerrado are discussed. The report lists actual and forthcoming publications resulting from the study. The mechanism of exchange of elements in solution in water to aerosols has been investigated. For details of the procedure the reader is referred to an earlier report

  8. PIXE and RBS applied to cultural heritage objects: Complementarity and limitations

    International Nuclear Information System (INIS)

    Morelle, M.; El Masri, Y.; Heitz, Ch.; Prieels, R.; Van Mol, J.; Dran, J.-C.; Salomon, J.; Calligaro, T.; Dubus, M.

    2005-01-01

    This paper reports on the use of PIXE and RBS (resonant and non-resonant RBS) implemented with proton beams to simultaneously analyse light and heavy elements in materials of cultural heritage significance, as exemplified by Russian icons or in lead seals. It is shown that in spite of its poor mass resolution RBS with protons can provide useful information when combined with PIXE. In the case of Russian icons, it is possible to discriminate between an Au-Ag bilayer and an alloy of these metals in the gilds. However, when applied to lead seals RBS with protons encounters a significant limitation due to some deficiency in the available computer programs used for spectrum processing

  9. Micro-PIXE mapping of mineral distribution in mature grain of two pearl millet cultivars

    Energy Technology Data Exchange (ETDEWEB)

    Minnis-Ndimba, R., E-mail: rminnis@tlabs.ac.za [iThemba LABS, National Research Foundation (South Africa); Kruger, J.; Taylor, J.R.N. [Department of Food Science and Institute for Food, Nutrition and Well-being, University of Pretoria (South Africa); Mtshali, C. [iThemba LABS, National Research Foundation (South Africa); Pineda-Vargas, C.A. [iThemba LABS, National Research Foundation (South Africa); Faculty of Health and Wellness Sciences, CPUT, Bellville (South Africa)

    2015-11-15

    Micro-proton-induced X-ray emission (micro-PIXE) was used to map the distribution of several nutritionally important minerals found in the grain tissue of two cultivars of pearl millet (Pennisetum glaucum (L.) R. Br.). The distribution maps revealed that the predominant localisation of minerals was within the germ (consisting of the scutellum and embryo) and the outer grain layers (specifically the pericarp and aleurone); whilst the bulk of the endosperm tissue featured relatively low concentrations of the surveyed minerals. Within the germ, the scutellum was revealed as a major storage tissue for P and K, whilst Ca, Mn and Zn were more prominent within the embryo. Fe was revealed to have a distinctive distribution pattern, confined to the dorsal end of the scutellum; but was also highly concentrated in the outer grain layers. Interestingly, the hilar region was also revealed as a site of high accumulation of minerals, particularly for S, Ca, Mn, Fe and Zn, which may be part of a defensive strategy against infection or damage. Differences between the two cultivars, in terms of the bulk Fe and P content obtained via inductively coupled plasma optical emission spectrometry (ICP-OES), concurred with the average concentration data determined from the analysis of micro-PIXE spectra specifically extracted from the endosperm tissue.

  10. The Van de Graaff facility

    International Nuclear Information System (INIS)

    Le Roux, E.; Peisach, M.; Pineda, C.A.; Pougnet, M.A.B.

    1987-01-01

    In many soils of the Western Cape growing region, toxic aluminium levels occur with a negative effect on vine performance. This investigation was aimed at studying the effect of such varying growth media on plant growth and the elemental content of the main nutrient element, in the roots. PIXE analysis was used in analyzing the pelleted root samples

  11. PIXE analysis of work environment aerosols

    International Nuclear Information System (INIS)

    Akabayashi, Hideo; Fujimoto, Fuminori; Komaki, Kenichiro; Ootuka, Akio; Kobayashi, Koichi; Yamashita, Hiroshi

    1988-01-01

    In labor environment, the quantity of chemical substances in the air is more, and their kinds are more diversified than in general home environment. It has been well known that some substances contained in the aerosol in labor environment (floating dust in the atmosphere) such as asbestos and hexavalent chromium have the possibility of causing serious injuries such as cancer of respiratory organ. In order to identify the harmful substances to which laborers are exposed and to take the measures for removing them, it is necessary to investigate in detail into many factors related to the effect of aerosol on human bodies, such as the composition of elements, chemical condition, concentration, the particle size of dust and temporal and spatial distributions. For the purpose, sampling and analysis must be carried out so that information can be extracted as much as possible from a minute amount of sample. The particle induced x-ray emission (PIXE) analysis is very effective for this application. In this paper, the development of a PIXE analysis system and the knowledge obtained by the sampling and measurement of aerosol in indoor labor environment are reported. The labor environment selected is that of the workshop of Department of Liberal Arts, University of Tokyo. Sampling, the experimental apparatus, the method of data analysis and the results of analysis are described. (Kako, I.)

  12. Microprobe PIXE study of Ni–Ge interactions in lateral diffusion couples

    Energy Technology Data Exchange (ETDEWEB)

    Chilukusha, D. [Department of Physics, University of Zambia, P.O. Box 32379, Lusaka 10101 (Zambia); Pineda-Vargas, C.A. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Faculty of Health & Wellness Sciences, CPUT, Bellville (South Africa); Nemutudi, R. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Habanyama, A. [Department of Physics, Copperbelt University, P.O. Box 21692, Jambo Drive, Riverside, Kitwe 10101 (Zambia); Comrie, C.M. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa)

    2015-11-15

    Rutherford backscattering spectrometry on the nuclear microprobe (μRBS) is often used in studies of lateral diffusion couples. RBS requires that the positions of the interacting species on the periodic table are not too close in terms of atomic number and therefore do not produce excessive RBS peak overlap. In order to satisfactorily characterize systems that have atomic numbers which are close, it is necessary to find techniques which can complement μRBS. The aim of this study was to determine the extent to which particle induced X-ray emission (PIXE) could be applied in the lateral diffusion couple study of a system with relatively close atomic numbers. This was with a view that it may eventually be adopted to study systems where the atomic numbers are too close for RBS analysis. The system studied here was the Ni–Ge binary system. Since RBS is an established technique for studying lateral diffusion couples, we used it as a standard for comparison. The PIXE results showed a maximum error of 12% with reference to the RBS standard. In order to achieve the most effective use of PIXE in lateral diffusion couple studies we recommend the use of the technique in such a way as to obtain depth information and the use of relatively thick sample layers.

  13. Siting of an MRS facility: identification of a geographic region that reduces transportation requirements

    International Nuclear Information System (INIS)

    Holter, G.M.; Braitman, J.L.

    1985-04-01

    The study reported here was undertaken as part of the site screening and evaluation activities for the Monitored Retrievable Storage (MRS) Program of the Office of Civilian Radioactive Waste Management (OCRWM), Department of Energy (DOE). Its primary purpose was to determine: the location and shape of a preferred geographic region within which locating an MRS facility would minimize total shipment miles for spent fuel transported through the MRS facility to a repository, and the sensitivity of the location and shape of this region and the reduction in total shipment miles to possible variations in waste management system logistics. As a result of this analysis, a geographic region has been identified which is preferred for siting an MRS facility. This region will be referred to as the preferred region in this study. Siting an MRS facility in the preferred region will limit total shipment miles (i.e., the total miles traveled for all shipments of spent fuel) to and from the MRS facility to within 20% of the lowest achievable. The region is preferred for a mixed truck/rail system of transport from reactors to the MRS facility. It is assumed that rail will be used to ship spent fuel from the MRS facility to a geologic repository for disposal. Siting an MRS facility in the preferred region will reduce total shipment miles for all currently considered system logistics options which include an MRS facility in the system. These options include: any first repository location, the possible range of spent fuel consolidation at the MRS, use of multi-cask or single-cask train shipments, use of current or future spent fuel transport casks, servicing only the first or both the first and second repositories, and shipment of fuel from western reactors either through the MRS facility or to a western facility (a second, smaller MRS facility or the first repository)

  14. PIXE channeling for concentration and location measurements of Zn- and Cd-dopants in InP single crystals

    International Nuclear Information System (INIS)

    Vogt, J.; Krause, H.; Flagmeyer, R.; Otto, G.; Lux, M.

    1993-01-01

    We present results of the determination of Cd- and Zn-dopants in InP single crystals using the PIXE and RBS spectrometry at our 2 MeV Van de Graaff accelerator. The (100) oriented crystals were doped by thermodiffusion of Cd and Zn atoms. For concentration and localization measurements we used the ion-channeling technique and energy dispersive spectrometry of proton induced X-ray emission (PIXE). Angular scans of the K-lines of In, Cd and Zn were obtained. The strong In X-rays were attenuated by a rhodium foil in front of the low energy Ge detector. The PIXE-channeling results were compared with SIMS and Hall-effect measurements. (orig.)

  15. 3D Micro-PIXE at atmospheric pressure: A new tool for the investigation of art and archaeological objects

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit; Karydas, Andreas-Germanos; Schuetz, Roman; Sokaras, Dimosthenis; Reiche, Ina; Roehrs, Stefan; Pichon, Laurent; Salomon, Joseph

    2007-01-01

    The paper describes a novel experiment characterized by the development of a confocal geometry in an external Micro-PIXE set-up. The position of X-ray optics in front of the X-ray detector and its proper alignment with respect to the proton micro-beam focus provided the possibility of carrying out 3D Micro-PIXE analysis. As a first application, depth intensity profiles of the major elements that compose the patina layer of a quaternary bronze alloy were measured. A simulation approach of the 3D Micro-PIXE data deduced elemental concentration profiles in rather good agreement with corresponding results obtained by electron probe micro-analysis from a cross-sectioned patina sample. With its non-destructive and depth-resolving properties, as well as its feasibility in atmospheric pressure, 3D Micro-PIXE seems especially suited for investigations in the field of cultural heritage

  16. PIXE analysis of ancient Jordanian pottery

    International Nuclear Information System (INIS)

    Saleh, N.; Carlsson, L.E.

    1981-01-01

    Proton-induced X-ray emission (PIXE) has been applied for the determination of 18 elements (Si, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, Nb, Ba and Pb) in two groups of pottery from two different sites in Jordan, Biblical Bozrah (BB) and Amman Citadel (AC). The analysis showed that the elements Zn, Rb, Sr, Zr and Ba were the most useful elements to study to be able to differentiate between the two groups of pottery. (orig.)

  17. PIXE analysis of powdered milk

    International Nuclear Information System (INIS)

    Hallak, A.B.

    1983-01-01

    An accelerator-based study, using proton-induced x-ray emission (PIXE) was performed on four full-cream and four half-cream brands of powdered milk commonly consumed in Jordan. The elements detected in the samples are S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. The significance of some of these elements is discussed from the viewpoint of nutrition and also their effect on milk processing and dairy technology. The standard reference milk sample, A-11, which is distributed by IAEA was also examined, and the results for trace elements detected are compared with the values certified by IAEA. (author)

  18. The Australian millipede Dicranogonus pix Jeekel, 1982 (Diplopoda, Polydesmida, Paradoxosomatidae): a species with and without paranota

    Science.gov (United States)

    Mesibov, Robert

    2014-01-01

    Abstract Dicranogonus pix Jeekel, 1982 occurs in Victoria and Tasmania, Australia, including the islands in eastern Bass Strait between the two States. There is only slight gonopod variation across this range, but Dicranogonus pix populations with and without paranota are separated in Bass Strait by the ca 50 km-wide gap between the Kent and Furneaux Groups of islands. PMID:25493065

  19. Building a fingerprint database for modern art materials: PIXE analysis of commercial painting and drawing media

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, A., E-mail: alessandro.zucchiatti@uam.es [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Climent-Font, A. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Departamento de Física Aplicada, Universidad Autónoma de Madrid, Avda. Francisco Tomás y Valiente 7, 28049 Madrid (Spain); Gómez-Tejedor, J. García [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain); Martina, S. [Centro de Micro Análisis de Materiales, Universidad Autónoma de Madrid, C/ Faraday 3, Madrid (Spain); Universitá degli Studi di Torino, Turin (Italy); Muro García, C.; Gimeno, E.; Hernández, P.; Canelo, N. [Museo Nacional Centro de Arte Reina Sofia, Departamento de Restauración, Calle Santa Isabel, 52, 28012 Madrid (Spain)

    2015-11-15

    We have examined by PIXE (and by RBS in parallel) about 180 samples of commercial painting and drawing media including pencils, pastels, waxes, inks, paints and paper. Given the high PIXE sensitivity we produced X-ray spectra at low collected charges and currents, operating in good conservation conditions. For drawing media containing inorganic components or a unique marker element, we have defined colouring agent fingerprints which correspond, when applicable, to the composition declared by the manufacturer. For thin layers, the ratios of areal densities of elements are close to those expected given the declared composition, which is promising from the perspective of compiling the database. The quantitative PIXE and RBS analysis of part of the set of samples is provided.

  20. PIXE analysis on the absorption of strontium by plants under hydroponic culture

    International Nuclear Information System (INIS)

    Oguri, Yoshiyuki; Kondo, Kotaro

    2016-01-01

    90 Sr is one of the most toxic radioactive nuclides emitted from nuclear disasters. By experiments using the compounds of stable isotopes of Sr, the behavior of this nuclide in plants can be simulated very well (R. S. Russell and H. M. Squire: J. Exp. Bot., Vol. 9, No. 2, pp. 262-276 (1958)). In this paper, we present an application of PIXE (Particle-Induced X-ray Emission) analysis (S. A. E. Johansson, et al.: Particle-Induced X-Ray Emission Spectrometry (PIXE), Wiley-Interscience, New York, ISBN-13: 978-0471589440 (1995)) in the study of Sr absorption by a herbal plant grown in a compact hydroponic setup. (J.P.N.)

  1. Discriminative study of white porcelains by INAA and PIXE

    International Nuclear Information System (INIS)

    Feng, X.Q.; Feng, S.L.; Meng, F.F.; Wang, H.M.; Liu, S.S.

    2005-01-01

    The fine white porcelains of Xing Kiln, Ding Kiln and Jingxing Kiln are very similar or alike in many aspects, such as typology of the vessel, texture of the body, colors of the body and the glaze. It is difficult for the archaeologists to distinguish the provenance using traditional methods. Nuclear analytical techniques (INAA, PIXE, XRF, SRXRF) have been widely employed for the provenance study of cultural relics in recent years due to their unique advantage, i.e. capable of nondestructive analysis. The element contents in the body and glaze of white porcelain shards with known provenance were determined by INAA and PIXE. In the meanwhile blind samples were prepared and analyzed in the same way. The differences of the element abundance patterns were processed by multivariate statistical analysis. On the basis of the analytical data and the statistical results, the discriminating criteria for provenance identification are obtained and verified by the blind samples.

  2. Multielemental analyses of isomorphous Indian garnet gemstones by XRD and external pixe techniques.

    Science.gov (United States)

    Venkateswarulu, P; Srinivasa Rao, K; Kasipathi, C; Ramakrishna, Y

    2012-12-01

    Garnet gemstones were collected from parts of Eastern Ghats geological formations of Andhra Pradesh, India and their gemological studies were carried out. Their study of chemistry is not possible as they represent mixtures of isomorphism nature, and none of the individual specimens indicate independent chemistry. Hence, non-destructive instrumental methodology of external PIXE technique was employed to understand their chemistry and identity. A 3 MeV proton beam was employed to excite the samples. In the present study geochemical characteristics of garnet gemstones were studied by proton induced X-ray emission. Almandine variety of garnet is found to be abundant in the present study by means of their chemical contents. The crystal structure and the lattice parameters were estimated using X-Ray Diffraction studies. The trace and minor elements are estimated using PIXE technique and major compositional elements are confirmed by XRD studies. The technique is found very useful in characterizing the garnet gemstones. The present work, thus establishes usefulness and versatility of the PIXE technique with external beam for research in Geo-scientific methodology. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. arXiv The MuPix System-on-Chip for the Mu3e Experiment

    CERN Document Server

    Augustin, Heiko

    2017-02-11

    Mu3e is a novel experiment searching for charged lepton flavor violation in the rare decay $\\mu^+ \\rightarrow e^+e^-e^+$. Decay vertex position, decay time and particle momenta have to be precisely measured in order to reject both accidental and physics background. A silicon pixel tracker based on $50\\,\\mu$m thin high voltage monolithic active pixel sensors (HV-MAPS) in a 1 T solenoidal magnetic field provides precise vertex and momentum information. The MuPix chip combines pixel sensor cells with integrated analog electronics and a periphery with a complete digital readout. The MuPix7 is the first HV-MAPS prototype implementing all functionalities of the final sensor including a readout state machine and high speed serialization with 1.25 Gbit/s data output, allowing for a streaming readout in parallel to the data taking. The observed efficiency of the MuPix7 chip including the full readout system is $\\geq99\\%$ in a high rate test beam.

  4. Improved Dynamic Analysis method for quantitative PIXE and SXRF element imaging of complex materials

    International Nuclear Information System (INIS)

    Ryan, C.G.; Laird, J.S.; Fisher, L.A.; Kirkham, R.; Moorhead, G.F.

    2015-01-01

    The Dynamic Analysis (DA) method in the GeoPIXE software provides a rapid tool to project quantitative element images from PIXE and SXRF imaging event data both for off-line analysis and in real-time embedded in a data acquisition system. Initially, it assumes uniform sample composition, background shape and constant model X-ray relative intensities. A number of image correction methods can be applied in GeoPIXE to correct images to account for chemical concentration gradients, differential absorption effects, and to correct images for pileup effects. A new method, applied in a second pass, uses an end-member phase decomposition obtained from the first pass, and DA matrices determined for each end-member, to re-process the event data with each pixel treated as an admixture of end-member terms. This paper describes the new method and demonstrates through examples and Monte-Carlo simulations how it better tracks spatially complex composition and background shape while still benefitting from the speed of DA.

  5. Improved Dynamic Analysis method for quantitative PIXE and SXRF element imaging of complex materials

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C.G., E-mail: chris.ryan@csiro.au; Laird, J.S.; Fisher, L.A.; Kirkham, R.; Moorhead, G.F.

    2015-11-15

    The Dynamic Analysis (DA) method in the GeoPIXE software provides a rapid tool to project quantitative element images from PIXE and SXRF imaging event data both for off-line analysis and in real-time embedded in a data acquisition system. Initially, it assumes uniform sample composition, background shape and constant model X-ray relative intensities. A number of image correction methods can be applied in GeoPIXE to correct images to account for chemical concentration gradients, differential absorption effects, and to correct images for pileup effects. A new method, applied in a second pass, uses an end-member phase decomposition obtained from the first pass, and DA matrices determined for each end-member, to re-process the event data with each pixel treated as an admixture of end-member terms. This paper describes the new method and demonstrates through examples and Monte-Carlo simulations how it better tracks spatially complex composition and background shape while still benefitting from the speed of DA.

  6. High energy PIXE: A tool to characterize multi-layer thick samples

    Science.gov (United States)

    Subercaze, A.; Koumeir, C.; Métivier, V.; Servagent, N.; Guertin, A.; Haddad, F.

    2018-02-01

    High energy PIXE is a useful and non-destructive tool to characterize multi-layer thick samples such as cultural heritage objects. In a previous work, we demonstrated the possibility to perform quantitative analysis of simple multi-layer samples using high energy PIXE, without any assumption on their composition. In this work an in-depth study of the parameters involved in the method previously published is proposed. Its extension to more complex samples with a repeated layer is also presented. Experiments have been performed at the ARRONAX cyclotron using 68 MeV protons. The thicknesses and sequences of a multi-layer sample including two different layers of the same element have been determined. Performances and limits of this method are presented and discussed.

  7. Applicability of PIXE for multielemental analysis in a biomedical application

    International Nuclear Information System (INIS)

    Shakir, N.S.

    1987-07-01

    The applicability of PIXE for multielemental analysis is demonstrated. The method is used in a major systematic study on hair samples using one target analysis. The pathological state considered is agitated elderly people. The main elements examined are S, K, Ca, Fe, Co, Ni, Cu, Zn, Se, Br, Hg and Pb. The minimum detectable limits are 1-10 ppm using 180 μg of dry hair at 25 μe irradiations for elements between K and Br. The significance of differences between the hair elements in control populations and patients suffering from the pathological conditions are investigated. Investigations of possible linear and multiple-correlations between elements in each population are made. The work indicates that some elements do exhibit variation with pathological state, and the multielement PIXE analysis gives useful information about the subject. (author). 13 refs, 4 figs, 6 tabs

  8. Low-level radioactive waste facility siting in the Rocky Mountain compact region

    International Nuclear Information System (INIS)

    Whitman, M.

    1983-09-01

    The puprose of the Rocky Mountain Low-Level Radioactive Waste Compact is to develop a regional management system for low-level waste (LLW) generated in the six states eligible for membership: Arizona, Colorado, Nevada, New Mexico, Utah and Wyoming. Under the terms of the compact, any party state generating at least 20% of the region's waste becomes responsible for hosting a regional LLW management facility. However, the compact prescribes no system which the host state must follow to develop a facility, but rather calls on the state to fulfill its responsibility through reliance on its own laws and regulations. Few of the Rocky Mountain compact states have legislation dealing specifically with LLW facility siting. Authority for LLW facility siting is usually obtained from radiation control statutes and solid or hazardous waste statutes. A state-by-state analysis of the siting authorities of each of the Rock Mountain compact states as they pertain to LLW disposal facility siting is presented. Siting authority for LLW disposal facilities in the Rocky Mountain compact region runs from no authority, as in Wyoming, to general statutory authority for which regulations would have to be promulgated, as in Arizona and Nevada, to more detailed siting laws, as in Colorado and New Mexico. Barring an amendment to, or different interpretation of, the Utah Hazardous Waste Facility Siting Act, none of the Rocky Mountain States' LLW facility siting authorities preempt local veto authorities

  9. Comparative study between the PIXE technique and neutron activation analysis for Zinc determination

    International Nuclear Information System (INIS)

    Cruvinel, Paulo Estevao; Crestana, Silvio; Artaxo Netto, Paulo Eduardo

    1997-01-01

    This work presents a comparative study between the PIXE, proton beams and neutron activation analysis (NAA) techniques, for determination of total zinc concentration. Particularly, soil samples from the Pindorama, Instituto Agronomico de Campinas, Sao Paulo State, Brazil, experimental station have been analysed and measuring the zinc contents in μg/g. The results presented good correlation between the mentioned techniques. The PIXE and NAA analyses have been carried out by using the series S, 2.4 MeV proton beams Pelletron accelerator and the IPEN/CNEN-IEA-R1 reactor, both installed at the Sao Paulo - Brazil university

  10. External beam milli-PIXE as analytical tool for Neolithic obsidian provenance studies

    Energy Technology Data Exchange (ETDEWEB)

    Constantinescu, B.; Cristea-Stan, D. [National Institute for Nuclear Physics and Engineering Horia Hulubei, Bucharest-Magurele (Romania); Kovács, I.; Szõkefalvi-Nagy, Z. [Wigner Research Centre for Phyics, Institute for Particle and Nuclear Physics, Budapest (Hungary)

    2013-07-01

    Full text: Obsidian is the most important archaeological material used for tools and weapons before metals appearance. Its geological sources are limited and concentrated in few geographical zones: Armenia, Eastern Anatolia, Italian Lipari and Sardinia islands, Greek Melos and Yali islands, Hungarian and Slovak Tokaj Mountains. Due to this fact, in Mesolithic and Neolithic periods obsidian was the first archaeological material intensively traded even at long distances. To determine the geological provenance of obsidian and to identify the prehistoric long-range trade routes and possible population migrations elemental concentration ratios can help a 101, since each geological source has its 'fingerprints'. In this work external milli-PIXE technique was applied for elemental concentration ratio determinations in some Neolithic tools found in Transylvania and in the lron Gales region near Danube, and on few relevant geological samples (Slovak Tokaj Mountains, Lipari,Armenia). In Transylvania (the North-Western part of Romania, a region surrounded by Carpathian Mountains), Neolithic obsidian tools were discovered mainly in three regions: North-West - Oradea (near the border with Hungary, Slovakia and Ukraine), Centre -Cluj and Southwest- Banat (near the border with Serbia). A special case is lron Gales - Mesolithic and Early Neolithic sites, directly related to the appearance of agriculture replacing the Mesolithic economy based on hunting and fishing. Three long-distance trade routes could be considered: from Caucasus Mountains via North of the Black Sea, from Greek islands or Asia Minor via ex-Yugoslavia area or via Greece-Bulgaria or from Central Europe- Tokaj Mountains in the case of obsidian. As provenance 'fingerprints', we focused on Ti to Mn, and Rb-Sr-Y-Zr ratios. The measurements were performed at the external milli-PIXE beam-line of the 5MV VdG accelerator of the Wigner RCP. Proton energy of 3MeV and beam currents in the range of 1 ±1 D

  11. External beam milli-PIXE as analytical tool for Neolithic obsidian provenance studies

    International Nuclear Information System (INIS)

    Constantinescu, B.; Cristea-Stan, D.; Kovács, I.; Szõkefalvi-Nagy, Z.

    2013-01-01

    Full text: Obsidian is the most important archaeological material used for tools and weapons before metals appearance. Its geological sources are limited and concentrated in few geographical zones: Armenia, Eastern Anatolia, Italian Lipari and Sardinia islands, Greek Melos and Yali islands, Hungarian and Slovak Tokaj Mountains. Due to this fact, in Mesolithic and Neolithic periods obsidian was the first archaeological material intensively traded even at long distances. To determine the geological provenance of obsidian and to identify the prehistoric long-range trade routes and possible population migrations elemental concentration ratios can help a 101, since each geological source has its 'fingerprints'. In this work external milli-PIXE technique was applied for elemental concentration ratio determinations in some Neolithic tools found in Transylvania and in the lron Gales region near Danube, and on few relevant geological samples (Slovak Tokaj Mountains, Lipari,Armenia). In Transylvania (the North-Western part of Romania, a region surrounded by Carpathian Mountains), Neolithic obsidian tools were discovered mainly in three regions: North-West - Oradea (near the border with Hungary, Slovakia and Ukraine), Centre -Cluj and Southwest- Banat (near the border with Serbia). A special case is lron Gales - Mesolithic and Early Neolithic sites, directly related to the appearance of agriculture replacing the Mesolithic economy based on hunting and fishing. Three long-distance trade routes could be considered: from Caucasus Mountains via North of the Black Sea, from Greek islands or Asia Minor via ex-Yugoslavia area or via Greece-Bulgaria or from Central Europe- Tokaj Mountains in the case of obsidian. As provenance 'fingerprints', we focused on Ti to Mn, and Rb-Sr-Y-Zr ratios. The measurements were performed at the external milli-PIXE beam-line of the 5MV VdG accelerator of the Wigner RCP. Proton energy of 3MeV and beam currents in the range of 1 ±1 D

  12. Development of the Jyvaeskylae microbeam facility

    Energy Technology Data Exchange (ETDEWEB)

    Norarat, Rattanaporn, E-mail: rattanaporn.norarat@phys.jyu.fi [Department of Physics, University of Jyvaeskylae, P.O. Box 35 (YFL), FIN-40014 Jyvaeskylae (Finland); Sajavaara, Timo; Laitinen, Mikko; Heikkinen, Pauli; Ranttila, Kimmo; Ylikorkala, Kari; Haenninen, Vaeinoe; Rossi, Mikko; Jones, Pete [Department of Physics, University of Jyvaeskylae, P.O. Box 35 (YFL), FIN-40014 Jyvaeskylae (Finland); Marjomaeki, Varpu; Gilbert, Leona [Department of Environmental and Biological Sciences, University of Jyvaeskylae, P.O. Box 35 (YFL), FIN-40014 Jyvaeskylae (Finland); Whitlow, Harry J. [Department of Physics, University of Jyvaeskylae, P.O. Box 35 (YFL), FIN-40014 Jyvaeskylae (Finland)

    2012-02-01

    Research highlights: Black-Right-Pointing-Pointer A MeV ion microbeam for biomedical materials research is being developed. Black-Right-Pointing-Pointer High accuracy scanning using electrostatic post-focus deflection. Black-Right-Pointing-Pointer Imaging and direct lithographic image writing using time-stamping methods. Black-Right-Pointing-Pointer New scanning modes and fluorescence detectors permit low ion-fluence cell imaging. Black-Right-Pointing-Pointer Thermal compensated beam-line support design for high positional accuracy. - Abstract: A new microbeam facility is being constructed at the 1.7 MV Pelletron Accelerator in Jyvaeskylae. The facility is designed for easy upgrading and incorporates a number of innovative features. Initially, it is based on a Heidelberg doublet with a design capability of a 3 Multiplication-Sign 5 {mu}m beamspot at PIXE intensities and later upgraded to nanobeam performance. A thermal-expansion compensated rigid frame mounted on a mechanically isolated floor section is used to support the ion optical components. A compact-post focusing electrostatic deflector is used for high linearity beam scanning. This together with a novel time-stamped data collection (TDC) allows dynamic effects in IBIC, fluorescence bleaching to be studied as well as facilitating multi-resolution image support for low-fluence imaging of cells. The target chamber is fitted with a novel low-cost large working distance optical microscope, extremely compact large solid angle photon detectors as well as conventional secondary electron, PIXE and Scanning Transmission Ion Microscopy (STIM) detectors.

  13. Paintings on copper by the Flemish artist Frans Francken II: PIXE characterization by external microbeam

    International Nuclear Information System (INIS)

    Corregidor, V.; Oliveira, A.R.; Rodrigues, P.A.; Alves, L.C.

    2015-01-01

    Resorting to an external proton microbeam, PIXE analyses of three oil paintings on copper support dated from the XVII century and attributed to the Flemish artist Frans Francken II, were undertaken. The present work aims to contribute to the compositional study of the painting materials employed by XVII century artists that exploited copper as a support for oil painting, and specifically the materials used by Francken’s workshop, particularly copper plates. Because of the low thickness of the pictorial layers of this type of paintings and its non-destructive character, PIXE is the ideal technique to study the elemental composition of the paintings. Several spots in each painting were chosen for analysis in order to cover almost all the pigments used in the colour palette. Lead and calcium were detected in practically every analysed regions, probably related to the presence of lead white and chalk, usually used as ground layer on copper paintings. Small quantities of gold were also detected, which is present in many of this artist’s works to embellish some details of the representations. Also this work reports the first application of the external proton microbeam set-up available at CTN/IST in Portugal for the characterization of oil paintings

  14. PIXE analysis of trace and other mineral elements in Romanian dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Moldovan, Maria

    2002-01-01

    Dental composites made of silicates and oxides particles embedded in an organic polymer, show a dynamic evolution but are rather expensive. Recently, the Romanian biomaterial 'Restacril' offered a low-cost alternative. Because the durability of the composite dental fillings depends both on the main chemical composition and on the impurities that may influence the inorganic particles' properties and thus modifying the bio material clinical behaviour, the elemental analysis of the material is necessary for improving its quality. Particle-induced X-ray emission (PIXE), a sensitive method for multielemental trace detection widely used in biomedical applications, allowed us to evidence 21 mineral elements with Z > 14 in some commercial dental composites. Here we evaluate the performances of PIXE for the control of dental composites by carrying out qualitative analysis of three Romanian biomaterials. PIXE measurements on thick composite samples with a flat surface were done with 3 MeV protons at the NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector, 30 mm thick Al absorber foil and integration of beam current. Up to 21 elements with Z > 19 were detected: K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Ga, Sr, Zr, Nb, Ru, Ag, Ba, Yb, Nd, Hf, Au, As and Pb. The orders of magnitude of relative concentrations were evaluated using X-ray yields obtained for another light element thick composite target. The Romanian composites have specific and diverse compositions, containing a great number of minor and trace elements, many of whom are impurities. Use of higher purity raw materials is suggested to reduce the latter and improve the materials' quality. Refinement of X-ray yields by better matching matrixes calculations and use of concentration standards are proposed for quantitative PIXE analysis of the dental composites. (authors)

  15. PIXE maps of intracellular element distribution in cerebellar neurons

    Czech Academy of Sciences Publication Activity Database

    Kranda, Karel; Havránek, Vladimír; Purkrtová, Z.; Vožeh, F.; Hájková, L.

    2012-01-01

    Roč. 22, 1-2 (2012), s. 65-72 ISSN 0129-0835 R&D Projects: GA ČR GA309/09/1189 Institutional support: RVO:61389005 Keywords : MicroPIXE * 2D-mapping * cerebellum * mutant mice * Purkinje cells * cell death * metan concentration Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  16. PIXE Analysis and source identification of airborne particulate matter collected in Downtown Havana City

    International Nuclear Information System (INIS)

    Perez, G.; Pinnera, I; Ramos, M; Guibert, R; Molina, E.; Martinez, M.; Fernandez, A.; Aldape, F.; Flores, M.

    2009-01-01

    A set of samples containing airborne particulate matter (in two particle size fraction PM10 and PM2,5) collected during five months from November 2006 to April 2007 in a urban area of Havana City were analyzed by Particle-Induced X-ray Emission (PIXE) technique and the concentrations of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were determined consistently in both particle size fractions with minimum detection limits in the range of ng/m3. A Gent air sampler was used for the aerosol collection in PM10 and PM2,5 particles simultaneously and the PIXE elemental analysis were performed using a proton beam of 2.5 MeV from the 2 MV Van de Graff Tandetron Accelerator at the ININ PIXE Laboratory in Mexico. The analytical database provided by PIXE was statistically analyzed in order to determine the promising local pollution sources. The statistical techniques of Multivariate Factor Analysis in combination with the Principal Component Analysis methods were applied to this data and allowed identifying five main pollution sources of airborne particulate matter (PM10 and PM2,5) collected in this area. The main (local) identified sources were: soil dust, sea spray, industry, fossil fuel combustion from motor vehicles and burnings or incinerations of diverse materials. A general discussion about these results is presented in this work. (Author)

  17. Design and characteristics of a scattering chamber for PIXE analysis

    International Nuclear Information System (INIS)

    Oliver, A.; Miranda, J.; Lopez, K.; Mercado, F.; Flores, A.H.

    1989-01-01

    A scattering chamber for Particle Induced x-ray Emission (PIXE) analysis is described. This chamber was designed and constructed for thin film thickness measurements and depth profiling. The chamber operation characteristics and versatility in materials analysis are shown. (Author). 18 refs, 6 figs

  18. PIXE and neutron activation analysis: intercomparison in the elemental concentration of airborne particulate matter

    International Nuclear Information System (INIS)

    Cassorla, V.; Rojas, X.; Gras, N.; Chuaqui, L.; Dinator, M.I.; Morales, J.R.; Llona, F.; Romo-Kroeger, C.

    1993-01-01

    Two nuclear analytical techniques, neutron activation analysis (NAA) and proton induced X-ray emission (PIXE), were used to determine major and trace elements in airborne particulate matter collected during the first fortnight of June 1991 at the La Reina Nuclear Center. NAA detected the presence of 15 elements in the samples. PIXE, for the same samples, allowed the detection of 12 elements. The elements determined by both techniques were Al, Ca, Mn, Fe, Cu, and Zn. A good correlation between results for these elements for each of the two techniques was demonstrated. (author)

  19. PIXE and PIGE analysis of pre-colonial pottery from Patanal - MS, Brazil

    International Nuclear Information System (INIS)

    Felicissimo, M.P.; Rodrigues-Filho, U.P.; Peixoto, J.L.; Barbosa, M.S.; Demortier, G.; Pireaux, J.J.

    2006-01-01

    PIXE and PIGE were applied to investigate the pottery from two archaeological sites located near the Brazil-Bolivia border in Pantanal, an area of natural preservation. The region was inhabited by ancient Amerindian tribes long before the Latin America colonization period and a deep understanding of their environment, cultural attributes and interconnections can only be achieved based on the study of archaeological findings. Multivariate statistical procedures were used to determine similarities and correlations between the analyzed samples and to indicate possible sources of raw material provenience. The results showed that traces of Cr, Cu and Ti and Na/Si and Mg/Si counting ratios were important to distinguish sherds from the archaeological sites MS-CP-71 and MS-CP-61. (author)

  20. PIXE application for measurement of bioaccumulation of lead by marine micro-algae

    International Nuclear Information System (INIS)

    Iwata, Y.; Suzuki, M.

    2000-01-01

    Marine micro-algae (Nannochloropsis sp., and Phaeodactylum sp.,) were obtained from the Pacific Ocean of Iwate Pref., Japan and purely cultured in nutritive seawater as a culture solution. The culture size for algae was 10-250 ml and every apparatus was small and of low cost. Marine micro-algae were given in different culture solutions including Pb 2+ from 0.01 to 1.0 mg/l. The algae in 5 ml of the culture solution were collected on a polycarbonate filter (pore size: 1.0 μm) by suction filtration. The algae on the filter were subjected to PIXE analysis. Concentrations of Na, Mg, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Cu, Zn, Sr and Pb were simultaneously determined. PIXE can do multi-element analysis for a sample of below 1 mg. The quantity of lead in marine micro-algae increases in proportion to the Pb 2+ concentration in the culture solution. The concentration factor (wet weight base) for lead is given as 200±20 ml/g for Nannochloropsis sp. and 1900±400 ml/g for Phaeodactylum sp.. It is shown that PIXE is a powerful tool for the measurement of the bioaccumulation of trace elements. (author)

  1. PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains

    Science.gov (United States)

    Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael

    2014-09-01

    We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.

  2. Nigerian coal analysis by PIXE and HEBS techniques

    International Nuclear Information System (INIS)

    Olabanji, S.O.

    1989-05-01

    PIXE and HEBS techniques were employed for the measurement of the concentrations of the major, minor and trace elements in Nigerian coal samples from a major deposit. The samples were irradiated with 2.55 MeV protons from the 3 MeV tandem accelerator (NEC 3 UDH) in Lund. The PIXE results are reported and compared with an earlier work on Nigerian coal using FNAA and INAA analytical techniques while the HEBS results are compared with ASTM previous results. The results corroborate the assertion that Nigerian coals are of weak and noncoking grades with low sulphur (0.82-0.99%) and relatively high hydrogen (4.49-5.16%) contents. The motivation for this work is partly due to the projected usage of coal as metallurgical feedstocks and as fuel, and partly because of the genuine concern about the concomitant environmental effects of the increased burning of coal. The knowledge of the concentration of all elements is important for the characterization of coal and the determination and control of its products. Economic parameters such as the ash contents and calorific values are associated with the concentrations of coal's constituents. (author). 11 refs, 1 fig., 4 tabs

  3. VeloPix ASIC for the LHCb VELO Upgrade

    CERN Multimedia

    Cid Vidal, Xabier

    2015-01-01

    The LHCb Vertex Detector (VELO) will be upgraded in 2018 along with the other subsystems of LHCb in order to enable full detector readout at 40 MHz. LHCb will run without a hardware trigger and all data will be fed directly to the software triggering algorithms in the CPU farm. The upgraded VELO is a lightweight silicon hybrid pixel detector with 55 um square pixels, operating in vacuum in close proximity to the LHC beams. The readout will be provided by a dedicated front end ASIC, dubbed VeloPix, matched to the LHCb luminosity requirements. VeloPix is a binary pixel chip with a matrix of 256 x 256 pixels, covering an area of 2 cm^2. It is designed in a 130 nm CMOS technology, and is closely related to the Timepix3, from the Medipix family of ASICs. The principal challenge that the chip has to meet is a hit rate of up to 900 Mhits/s/ASIC, resulting in a data rate of more than 16 Gbit/s. Combining pixels into groups of 2x4 super-pixels enables the use of shared logic and a reduction of bandwidth due to combine...

  4. Application of micro-PIXE, MRI and light microscopy for research in wood science and dendroecology

    International Nuclear Information System (INIS)

    Merela, M.; Pelicon, P.; Vavpetic, P.; Regvar, M.; Vogel-Mikus, K.; Sersa, I.; Policnik, H.; Pokorny, B.; Levanic, T.; Oven, P.

    2009-01-01

    Beech (Fagus sylvatica L.) branches were topped and after five months the wound response was analyzed by PIXE, 3D-MRI and light microscopy. From freshly cut and deeply frozen sample 30 μm thick longitudinal-radial tissue sections were prepared for anatomical investigations and micro-PIXE analysis. Light microscopy revealed the structural response to wounding, i.e. occurrence of the reaction zone between the exposed and dehydrated dead tissue and healthy sound wood. The reaction zone was characterized by tylosis in vessels and accumulation of colored deposits in parenchyma cells, fibres and vessels. 3D MRI of a parallel sample showed that the moisture content in the reaction zone was three times higher than in normal healthy wood. Micro-PIXE mapping at margins of compromised wood in beech revealed an increased concentration of potassium in the reaction zone. The increase in the calcium concentration was associated with the dehydrated tissue adjacent to reaction zones. In addition, micro-PIXE was used to determine the elemental distribution in annual tree rings. This may be relevant for retrospective assessment of environmental pollution in wood by measuring yearly increments as a biomonitoring tool. The analysis of European larch (Larix decidua Mill.) wood revealed a high similarity between optical characteristics (i.e. late versus earlywood) and elemental (e.g. Cl, K, Ca, Mn, Zn) distribution.

  5. Evaluation of specimen preparation techniques for micro-PIXE localisation of elements in hyperaccumulating plants

    International Nuclear Information System (INIS)

    Kachenko, Anthony G.; Siegele, Rainer; Bhatia, Naveen P.; Singh, Balwant; Ionescu, Mihail

    2008-01-01

    Hybanthus floribundus subsp. floribundus, a rare Australian Ni-hyperaccumulating shrub and Pityrogramma calomelanos var. austroamericana, an Australian naturalized As-hyperaccumulating fern are promising species for use in phytoremediation of contaminated sites. Micro-proton-induced X-ray emission (μ-PIXE) spectroscopy was used to map the elemental distribution of the accumulated metal(loid)s, Ca and K in leaf or pinnule tissues of the two plant species. Samples were prepared by two contrasting specimen preparation techniques: freeze-substitution in tetrahydrofuran (THF) and freeze-drying. The specimens were analysed to compare the suitability of each technique in preserving (i) the spatial elemental distribution and (ii) the tissue structure of the specimens. Further, the μ-PIXE results were compared with concentration of elements in the bulk tissue obtained by ICP-AES analysis. In H. floribundus subsp. floribundus, μ-PIXE analysis revealed Ni, Ca and K concentrations in freeze-dried leaf tissues were at par with bulk tissue concentrations. Elemental distribution maps illustrated that Ni was preferentially localised in the adaxial epidermal tissues (1% DW) and least concentration was found in spongy mesophyll tissues (0.53% DW). Conversely, elemental distribution maps of THF freeze-substituted tissues indicated significantly lower Ni, Ca and K concentrations than freeze-dried specimens and bulk tissue concentrations. Moreover, Ni concentrations were uniform across the whole specimen and no localisation was observed. In P. calomelanos var. austroamericana freeze-dried pinnule tissues, μ-PIXE revealed statistically similar As, Ca and K concentrations as compared to bulk tissue concentrations. Elemental distribution maps showed that As localisation was relatively uniform across the whole specimen. Once again, THF freeze-substituted tissues revealed a significant loss of As compared to freeze-dried specimens and the concentrations obtained by bulk tissue analysis

  6. PIXE characterization of by-products resulting from the zinc recycling of industrial cemented carbides

    International Nuclear Information System (INIS)

    Freemantle, C.S.; Sacks, N.; Topic, M.; Pineda-Vargas, C.A.

    2015-01-01

    By-product materials of the widely used zinc recycling process of cemented carbides have been studied. Scanning electron microscopy and micro-PIXE techniques have identified elemental concentrations, distributions and purity of by-product materials from an industrial zinc recycling plant. Cobalt surface enrichment, lamellar microstructures of varying composition, including alternating tungsten carbide (WC) grains and globular cobalt, and regions of excess zinc contamination were found in materials with incomplete zinc penetration. Liquid Co–Zn formation occurred above 72 wt.% Zn at the furnace temperature of 930 °C, and was extracted towards the surface of poorly zinc infiltrated material, primarily by the vacuum used for zinc distillation. Surface enrichment was not observed in material that was zinc infiltrated to the sample center, which was more friable and exhibited more homogeneous porosity and elemental concentrations. The result of incomplete zinc infiltration was an enriched surface zone of up to 60 wt.% Co, compared to an original sample composition of ∼10–15 wt.% Co. The impact on resulting powders could be higher or inhomogeneous cobalt content, as well as unacceptably high zinc concentrations. PIXE has proven it can be a powerful technique for solving industrial problems in the cemented carbide cutting tool industry, by identifying trace elements and their locations (such as Zn to 0.1 wt.% accuracy), as well as the distribution of major elements within WC–Co materials.

  7. PIXE characterization of by-products resulting from the zinc recycling of industrial cemented carbides

    Energy Technology Data Exchange (ETDEWEB)

    Freemantle, C.S. [School of Chemical & Metallurgical Engineering and DST-NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, P/Bag 3, Wits 2050 (South Africa); Pilot Tools (Pty) (Ltd), P.O. Box 27420, Benrose 2011 (South Africa); Sacks, N. [School of Chemical & Metallurgical Engineering and DST-NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, P/Bag 3, Wits 2050 (South Africa); Topic, M. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Pineda-Vargas, C.A. [iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Faculty of Health & Wellness Sciences, CPUT, Bellville (South Africa)

    2015-11-15

    By-product materials of the widely used zinc recycling process of cemented carbides have been studied. Scanning electron microscopy and micro-PIXE techniques have identified elemental concentrations, distributions and purity of by-product materials from an industrial zinc recycling plant. Cobalt surface enrichment, lamellar microstructures of varying composition, including alternating tungsten carbide (WC) grains and globular cobalt, and regions of excess zinc contamination were found in materials with incomplete zinc penetration. Liquid Co–Zn formation occurred above 72 wt.% Zn at the furnace temperature of 930 °C, and was extracted towards the surface of poorly zinc infiltrated material, primarily by the vacuum used for zinc distillation. Surface enrichment was not observed in material that was zinc infiltrated to the sample center, which was more friable and exhibited more homogeneous porosity and elemental concentrations. The result of incomplete zinc infiltration was an enriched surface zone of up to 60 wt.% Co, compared to an original sample composition of ∼10–15 wt.% Co. The impact on resulting powders could be higher or inhomogeneous cobalt content, as well as unacceptably high zinc concentrations. PIXE has proven it can be a powerful technique for solving industrial problems in the cemented carbide cutting tool industry, by identifying trace elements and their locations (such as Zn to 0.1 wt.% accuracy), as well as the distribution of major elements within WC–Co materials.

  8. Preliminary results of Sr:Ca ratios of Coilia nasus in otoliths by micro-PIXE

    International Nuclear Information System (INIS)

    Zhong, L.; Guo, H.; Shen, H.; Li, X.; Tang, W.; Liu, J.; Jin, J.; Mi, Y.

    2007-01-01

    Coilia nasus, distributed in Changjiang River as well as northwest Pacific, has a high economic value owing to its delicacy and nutritional value. Recently, the fishing yields in Changjiang River have decreased dramatically due to excessive fishing and changes in the aquatic ecology. In order to prevent excessive fishing effectively, the life history pattern of C. nasus should be known in detail. Ootoliths contain much information about a fish's life history, because elemental concentrations remain unaltered after deposition, and can be analysed. C. nasus collected from Jing Jiang (lower reaches of the Changjiang River) and Jiu Duan Sha (the estuary of the Changjiang River) were studied by measuring Sr:Ca ratios in their otoliths using micro-PIXE. On average, the Sr:Ca ratios of estuarine C. nasus were found to be higher. The Sr:Ca ratios were higher in the core regions and lower in the outermost marginal regions, and shows fluctuations in certain regions. Possible corresponding life history patterns are discussed

  9. Trace metal content in aspirin and women's cosmetics via proton induced x-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Hichwa, B.P.; Pun, D.D.; Wang, D.

    1981-01-01

    A multielemental analysis to determine the trace metal content of generic and name-brand aspirins and name-brand lipsticks was done via proton induced x-ray (PIXE) measurements. The Hope College PIXE system is described as well as the target preparation methods. The trace metal content of twelve brands of aspirin and aspirin substitutes and fourteen brands of lipstick are reported. Detection limits for most elements are in the range of 100 parts per billion (ppb) to 10 parts per million

  10. Analysis of biological materials by RBS and PIXE methods

    International Nuclear Information System (INIS)

    Latuszynski, A.; Maczka, D.; Kobzev, A. P.

    2002-01-01

    A problem of the exact determination of the element concentration in different substances is of essential significance, especially in medical, biological, as well as environment protection investigations. For this purpose some chemical and physical methods are used such as very sensitive and precise techniques: PIXE and RBS. The main advantage of those methods is the sensitivity of ppm level and very small sample amount necessary for carrying out the investigations. In this article the investigation results obtained by PIXE and RBS methods for the metal contents in cow milk (18 various samples were studied) as well as the heavy metal admixtures in the brain of the living domestic animals (6 cows, 6 dogs and 17 rats) are presented. The samples were prepared for the analysis in a liofilization process, then they were mixed with spectral pure graphite. The PIXE and RBS investigations were performed using a proton beam of about 2 mm diameter, intensity of about 10 nA and energy of 2.5 MeV from the Van-de-Graaff generator, FLNP, JINR, Dubna. The measurements of the characteristic spectrum were carried out by means of a Si (Li) detector with the resolution of 200 eV at the energy of 6,4 keV. Generally, in all samples of milk and brain we could identify 20 elements, among them 13 (C, N, O, P, Cl, K, Ca, Fe, Cu, Zn. Br, Rb, Sr) appeared in all of the studied samples. The difference in the concentration of the most of those elements between samples was in the range of 15 - 20 %. This indicates a good accuracy of the used methods of measurement. Especially our attention was paid to the presence of Sr, Rb and Br, practically in all the milk samples. This fact requires further investigations. Such elements as Pb, As, Ni, Co, Mn, V and Ti were found in some samples, including all samples coming from regions of a high urbanization. It is characteristic that the milk samples coming from villages located considerably far-away from cities and from communication tracks, practically

  11. PIXE and ICP-MS Analysis of Andrographis Paniculata Medicinal Plant

    Science.gov (United States)

    Chandrasekhar Rao, J.; Naidu, B. G.; Sarita, P.; Srikanth, S.; Naga Raju, G. J.

    2017-08-01

    The concentrations of elements Li, Be, Al, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Ag, Cd, Ba, Pb and U in Andrographis Paniculata medicinal plant used in the treatment of Diabetes Mellitus were determined by using Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) techniques. This plant was collected from four different geographical locations in Andhra Pradesh, India in order to assess the regional variation of elemental concentrations. Appreciable levels of K, Ca, Cr, Mn, Cu and Zn determined in this plant can be correlated to the antidiabetic property of Andrographis Paniculata since these elements are known to regulate and potentiate insulin action. Presence of toxic elements As, Cd and Pb necessitates the adoption of precautionary measures while prescribing dosage of the herbal medicine prepared from this plant for the treatment diabetes mellitus.

  12. Improvements in PIXE analysis of hourly particulate matter samples

    Energy Technology Data Exchange (ETDEWEB)

    Calzolai, G., E-mail: calzolai@fi.infn.it [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Lucarelli, F. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Chiari, M.; Nava, S. [National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Giannoni, M. [National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Department of Chemistry, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Italy); Carraresi, L. [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); National Institute of Nuclear Physics (INFN), Division of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Prati, P. [Department of Physics, University of Genoa and INFN Division of Genoa, Via Dodecaneso 33, 16146 Genoa (Italy); Vecchi, R. [Department of Physics, Università degli Studi di Milano and INFN Division of Milan, Via Celoria 16, 20133 Milan (Italy)

    2015-11-15

    Most air quality studies on particulate matter (PM) are based on 24-h averaged data; however, many PM emissions as well as their atmospheric dilution processes change within a few hours. Samplings of PM with 1-h resolution can be performed by the streaker sampler (PIXE International Corporation), which is designed to separate the fine (aerodynamic diameter less than 2.5 μm) and the coarse (aerodynamic diameter between 2.5 and 10 μm) fractions of PM. These samples are efficiently analyzed by Particle Induced X-ray Emission (PIXE) at the LABEC laboratory of INFN in Florence (Italy), equipped with a 3 MV Tandetron accelerator, thanks to an optimized external-beam set-up, a convenient choice of the beam energy and suitable collecting substrates. A detailed description of the adopted set-up and results from a methodological study on the detection limits for the selection of the optimal beam energy are shown; the outcomes of the research on alternative collecting substrates, which produce a lower background during the measurements, and with lower contaminations, are also discussed.

  13. VizieR Online Data Catalog: Spectrophotometric distances of HII regions (Moises+, 2011)

    Science.gov (United States)

    Moises, A. P.; Damineli, A.; Figueredo, E.; Blum, R. D.; Conti, P. S.; Barbosa, C. L.

    2011-11-01

    The J-band (λ1.28um, δλ=0.3um), H-band (λ1.63um, δλ=0.3um) and Ks-band (λ2.19um, δλ=0.4um) images were obtained on the nights of 1999 May 1, 4 and 20, 2000 May 19 and 21 and 2001 July 10 and 12, at the Cerro Tololo Inter-American Observatory (CTIO) 4-m Blanco telescope, using the facility's infrared imager OSIRIS, which has a field of view (FOV) of 93x93arcsec2 and a pixel scale of 0.161arcsec/pixel. On the nights of 2005 Jult 3-6 and 11 and 2006 June 3-7, we obtained images using the facility's infrared imager ISPI (with a FOV of 10.25x10.25arcmin2 and a pixel scale of 0.3arcsec/pix), also at the 4-m Blanco telescope. Also, on the nights of 1998 August 28 and 29, we obtained images on the CTIO 4-m telescope using the facility's infrared imager CIRIM (with a FOV of 102x102arcsec2 and a pixel scale of 0.40arcsec/pix). (3 data files).

  14. PIXE analysis of marine environmental samples from the Pacific Ocean

    International Nuclear Information System (INIS)

    Miyake, Hiroshi; Matsuda, Yasuhiro; Shitashima, Kiminori; Tsubota, Hiroyuki.

    1990-01-01

    Aerosol samples from the western North Pacific Ocean are collected during a cruise of R/V Hakuhomaru from Japan to Hawaii and they are analyzed by PIXE (particle induced X-ray emission). Concentrations of radon daughters are measured with CR-39 track detectors mounted on the impactor to estimate the transport time of air mass from the Asian Continent. Distributions of particulate element concentrations clearly demonstrate the influence of the westerlies. Strong correlations are observed between fine sulphur concentrations and those of heavy metals such as Fe and Zn. Vertical profiles of heavy metal elements contained in marine particulates are also investigated at a trench in the Pacific Ocean and basins in the Japan Sea. Particulate element concentrations determined by PIXE agree well with those determined by chemical analysis of filtered/total water. Remarkable changes in depth profiles of particulate manganese are observed at the trench, which suggest horizontal transport of marine particulates from the trench wall. (N.K.)

  15. Calibration of a PIXE system for analysis of environmental aerosols

    International Nuclear Information System (INIS)

    Aldape, F.; Diaz, R.V.; Anguiano, G.; Flores M, J.

    1991-04-01

    The results of the calibration of the PIXE system for analysis of environmental aerosols in the CNM is presented. The system was calibrated in order to lead to the project study of environmental aerosols using PIXE from the qualitative dimension to the quantitative one. Part of this work it was carried out in collaboration with the expert of the IAEA Dr. D. Crumpton. The calibration of the system it was achieved bombarding thin targets of well-known composition with protons of 2.5 MeV. Using this technique it was determined the absolute elementary concentration in samples of atmospheric aerosols. As an example the calculation of the lead concentration in one of them whose result was of 662 ± 49 ng m -3 is presented. This value agrees with the measurements made in the Crocker Nuclear Lab of the UCD. Its are also discussed the reproducibility and precision of the used technique. (Author)

  16. Some new results of PIXE study on Chinese ancient porcelain

    Science.gov (United States)

    Cheng, H. S.; Zhang, B.; Zhu, D.; Yang, F. J.; Sun, X. M.; Guo, M. S.

    2005-10-01

    This paper reports some new results obtained by PIXE on Chinese ancient porcelain. The first results concern the provenance of blue and white porcelain made during the Tang Dynasty (AD618-907), which are the earliest products found in China. The PIXE experimental results show that they were fired in Huangye Kiln, Gongyi, Henan Province. The chemical composition of the body, white glaze and of the cobalt pigment will be reported. This paper also reports the results for early Chinese blue and white porcelain made under the Yuan dynasty (AD1206-1368) in Jingdezhen, Jiangxi Province. Experimental results show that the chemical composition of the cobalt pigment used by officers and popular are similar. These materials were imported from another country. The local asbolite was used as cobalt pigment material since the early Ming Dynasty (AD1368-1644) in Jingdezhen at folk kiln, and it was used at official kiln until the 16th century.

  17. Some new results of PIXE study on Chinese ancient porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, H.S. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Zhang, B. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Zhu, D. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Sun, X.M. [Cultural Relics and Archaeology Research Institute of Henan Province, Zheng Zhou 450000 (China); Guo, M.S. [Cultural Relics and Archaeology Research Institute of Henan Province, Zheng Zhou 450000 (China)

    2005-10-15

    This paper reports some new results obtained by PIXE on Chinese ancient porcelain. The first results concern the provenance of blue and white porcelain made during the Tang Dynasty (AD618-907), which are the earliest products found in China. The PIXE experimental results show that they were fired in Huangye Kiln, Gongyi, Henan Province. The chemical composition of the body, white glaze and of the cobalt pigment will be reported. This paper also reports the results for early Chinese blue and white porcelain made under the Yuan dynasty (AD1206-1368) in Jingdezhen, Jiangxi Province. Experimental results show that the chemical composition of the cobalt pigment used by officers and popular are similar. These materials were imported from another country. The local asbolite was used as cobalt pigment material since the early Ming Dynasty (AD1368-1644) in Jingdezhen at folk kiln, and it was used at official kiln until the 16th century.

  18. Some new results of PIXE study on Chinese ancient porcelain

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, B.; Zhu, D.; Yang, F.J.; Sun, X.M.; Guo, M.S.

    2005-01-01

    This paper reports some new results obtained by PIXE on Chinese ancient porcelain. The first results concern the provenance of blue and white porcelain made during the Tang Dynasty (AD618-907), which are the earliest products found in China. The PIXE experimental results show that they were fired in Huangye Kiln, Gongyi, Henan Province. The chemical composition of the body, white glaze and of the cobalt pigment will be reported. This paper also reports the results for early Chinese blue and white porcelain made under the Yuan dynasty (AD1206-1368) in Jingdezhen, Jiangxi Province. Experimental results show that the chemical composition of the cobalt pigment used by officers and popular are similar. These materials were imported from another country. The local asbolite was used as cobalt pigment material since the early Ming Dynasty (AD1368-1644) in Jingdezhen at folk kiln, and it was used at official kiln until the 16th century

  19. High Resolution and Differential PIXE combined with RBS, EBS and AFM analysis of magnesium titanate (MgTiO3) multilayer structures

    International Nuclear Information System (INIS)

    Reis, M.A.; Alves, L.C.; Barradas, N.P.; Chaves, P.C.; Nunes, B.; Taborda, A.; Surendran, K.P.; Wu, A.; Vilarinho, P.M.; Alves, E.

    2010-01-01

    Thorough structural characterization of deep laying thin film, including the inference of interdiffusion profiles is frequently a complex problem. The use of RBS/PIXE holistic approaches, already shown to represent a powerful method, sometimes faces difficulties if standard experimental procedures are used. In this work, following a series of 4 He Rutherford backscattering and 1 H elastic backscattering experiments, carried out to study the influence of SrTiO 3 as a possible cladding layer between Pt/TiO 2 /SiO 2 /(1 0 0)Si substrates and MgTiO 3 films, a simple holistic RBS-PIXE is shown to be not enough for the solution of such a problem. Establishing of the Sr depth profile, was only possible after AFM, High-Resolution EDS PIXE and differential PIXE analysis were carried out. Results, problems faced and conclusions obtained are presented.

  20. PixFEL: developing a fine pitch, fast 2D X-ray imager for the next generation X-FELs

    International Nuclear Information System (INIS)

    Ratti, L.; Comotti, D.; Fabris, L.; Grassi, M.; Lodola, L.; Malcovati, P.; Manghisoni, M.; Re, V.; Traversi, G.; Vacchi, C.; Bettarini, S.; Casarosa, G.; Forti, F.; Morsani, F.; Paladino, A.; Paoloni, E.; Rizzo, G.; Benkechkache, M.A.; Dalla Betta, G.-F.; Mendicino, R.

    2015-01-01

    The PixFEL project is conceived as the first stage of a long term research program aiming at the development of advanced X-ray imaging instrumentation for applications at the free electron laser (FEL) facilities. The project aims at substantially advancing the state-of-the-art in the field of 2D X-ray imaging by exploring cutting-edge solutions for sensor development, for integration processes and for readout channel architectures. The main focus is on the development of the fundamental microelectronic building blocks for detector readout and on the technologies for the assembly of a multilayer module with minimum dead area. This work serves the purpose of introducing the main features of the project, together with the simulation results leading to the first prototyping run

  1. Identification of elements in polutants of Mexico City's atmosphere, using the pixe analysis

    International Nuclear Information System (INIS)

    Diaz-Godoy, R.V.

    1990-01-01

    A review of the fundamentals and actual state in Mexico of the pixe (particle induced X- ray emission) technique are done. Elemental identification in samples of Mexico City's atmosphere taken in two sites is performed using this technique. A 3 MeV proton beam is used to irradiate the samples. Factors (Bremsstrahlung and interference) that difficult the use of the technique are discussed. The sensitivity of the method is enhanced as a main characteristic. It is shown that tje pixe technique together with an appropriate sampling system can be used to study environmental aerosols. Identified elements are bromine, lead, copper, iron, zinc, titanium, vanadium, calcium, potassium, chlorine, sulfur and silicon. Temporal variations of these elements are discussed. (Author)

  2. PIXE measurements of Renaissance silverpoint drawings at VERA

    Energy Technology Data Exchange (ETDEWEB)

    Milota, Petra [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Reiche, Ina; Duval, Alain [Centre de recherche et de restauration des musees de France (C2RMF), CNRS UMR 171, Palais du Louvre, F-75001 Paris (France); Forstner, Oliver [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Guicharnaud, Helene [Centre de recherche et de restauration des musees de France (C2RMF), CNRS UMR 171, Palais du Louvre, F-75001 Paris (France); Kutschera, Walter [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Merchel, Silke [Centre Europeen de Recherche et d' Enseignement des Geosciences de l' Environnement (CEREGE), CNRS UMR 6635, F-13545 Aix en Provence (France); Priller, Alfred [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Schreiner, Manfred [Institute of Science and Technology in Art, Academy of Fine Arts Vienna, A-1010 Vienna (Austria); Steier, Peter [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Thobois, Elisabeth [Albertina, Albertinaplatz 1, A-1010 Vienna (Austria); Wallner, Anton; Wuenschek, Barbara [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria); Golser, Robin [Faculty of Physics, Isotope Research, University of Vienna, A-1090 Vienna (Austria)], E-mail: robin.golser@univie.ac.at

    2008-05-15

    Silverpoint drawings from the Renaissance are among the most precious and rarest treasures of graphical art. Our research group is particularly interested in the analysis of silverpoint drawings by Albrecht Duerer (1471-1528). A very sensitive and non-destructive analytical method, either spatially resolved synchrotron-radiation induced X-ray fluorescence (SY-XRF) or proton-induced X-ray emission (PIXE), is needed to determine the chemical composition of the very faint silver marks on such drawings. Duerer drawings from the collection of the Albertina, Vienna, were analyzed to amend existing data on Duerer drawings. For this purpose an external-beam PIXE setup was installed at the Vienna Environmental Research Accelerator (VERA). It allows to analyze a spot of {approx}0.15 mm on the object in air with 3 MeV protons, and to detect the emitted X-rays that are characteristic for the chemical composition with very good sensitivity and without harming the precious objects. After successful measurements on artificial test samples, four original silverpoint drawings were investigated: two portraits from Albrecht Duerer's very early period (self-portrait and portrait of his father) and two drawings from Duerer's sketch book of his travel to the Netherlands 1520/21.

  3. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    International Nuclear Information System (INIS)

    Deibel, M.A.; Savage, J.M.; Robertson, J.D.; Ehmann, W.D.

    1995-01-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer's disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the μg/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 μ/g for the trabecular surface by PIXE, 1.3-45 μg/g for the cortical surface by PIXE, and 1.54-11.75 μg/g for whole bone by GFAAS. No significant difference (p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs

  4. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Deibel, M A; Savage, J M; Robertson, J D; Ehmann, W D [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Markesbery, W R [Kentucky Univ., Lexington, KY (United States)

    1995-08-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer`s disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the {mu}g/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 {mu}/g for the trabecular surface by PIXE, 1.3-45 {mu}g/g for the cortical surface by PIXE, and 1.54-11.75 {mu}g/g for whole bone by GFAAS. No significant difference p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs.

  5. Application of micro-PIXE analysis to investigate trace elements in deciduous teeth enamel

    International Nuclear Information System (INIS)

    Igari, K.; Takahashi, A.; Ando, H.

    2010-01-01

    The early life environment has widespread consequences for later health and disease. To prevent the disease in later life, the assessment of fetal environment is very important. In Japan, birthweight has fallen rapidly during recent two decades. The reduction of birthweight represents reduced fetal nutrition. Deciduous tooth enamel contains pre- and postnatal enamel and its chemical composition reflects the status of metabolism of trace elements during formation period. Deciduous tooth enamel is considered to be a suitable indicator of trace elements exposure in utero. We applied micro-PIXE analysis to investigate the trace elemental content in deciduous tooth enamel. Two deciduous canines from one healthy Japanese boy were used for this study. The enamel section including pre- and postnatal enamel was prepared for micro-PIXE analysis. Five trace elements (Na, Mg, Cl, Zn, and Sr) were detected in the scanning area of tooth. The distribution profiles of 5 elements were obtained as X-ray maps. The distribution profiles of zinc and chlorine were specific, and showed higher concentration in surface enamel. No elements showed different profiles of X-ray maps between pre- and postnatal enamel in this sample. The results of this study suggested that micro-PIXE analysis would be able to estimate the trace elements in prenatal and postnatal enamel, respectively. (author)

  6. LePix-A high resistivity, fully depleted monolithic pixel detector

    CERN Document Server

    Giubilato, P; Mugnier, H; Bisello, D; Marchioro, A; Snoeys, W; Denes, P; Pantano, D; Rousset, J; Mattiazzo, S; Kloukinas, K; Potenza, A; Rivetti, A; Chalmet, P

    2013-01-01

    The LePix project explores monolithic pixel sensors fabricated in a 90 nm CMOS technology built over a lightly doped substrate. This approach keeps the advantages usually offered by Monolithic Active Pixel Sensors (MAPS), like a low input capacitance, having a single piece detector and using a standard CMOS production line, and adds the benefit of charge collection by drift from a depleted region several tens of microns deep into the substrate, therefore providing an excellent signal to noise ratio and a radiation tolerance superior to conventional un-depleted MAPS. Such sensors are expected to offer significant cost savings and reduction of power consumption for the same performance, leading to the use of much less material in the detector (less cooling and less copper), addressing one of the main limitations of present day particle tracking systems. The latest evolution of the project uses detectors thinned down to 50 mu m to obtain back illuminated sensors operated in full depletion mode. By back processin...

  7. Micro-PIXE evaluation of radioactive cesium transfer in contaminated soil samples

    International Nuclear Information System (INIS)

    Fujishiro, F.; Ishii, K.; Matsuyama, S.; Arai, H.; Ishizaki, A.; Osada, N.; Sugai, H.; Kusano, K.; Nozawa, Y.; Yamauchi, S.; Karahashi, M.; Oshikawa, S.; Kikuchi, K.; Koshio, S.; Watanabe, K.; Suzuki, Y.

    2014-01-01

    Highlights: • There are radioactively contaminated soils having a radioactive cesium transfer of 0.01. • Micro-PIXE analysis has revealed an existence of phosphorus in a contaminated soil. • Radioactive cesium captured by phosphorus compound would be due to radioactive transfer. -- Abstract: Micro-PIXE analysis has been performed on two soil samples with high cesium activity concentrations. These soil samples were contaminated by fallout from the accident at Fukushima Daiichi Nuclear Power Plant. One exhibits a radioactive cesium transfer of ∼0.01, and the other shows a radioactive cesium transfer of less than 0.001, even though both samples have high cesium activity concentrations exceeding 10,000 Bq/kg. X-ray spectra and elemental images of the soil samples revealed the presence of chlorine, which can react with cesium to produce an inorganic soluble compound, and phosphorus-containing cesium-capturable organic compounds

  8. Thick-target Pixe analysis of chromium, copper and arsenic impregnated lumber

    International Nuclear Information System (INIS)

    Saarela, K-E.; Harju, L.; Lill, J-O.; Rajander, J.; Lindroos, A.; Heselius, S-J.

    1999-01-01

    Chromium, copper and arsenic (CCA) have for decades been used for wood preservation. Of these elements especially arsenic is very toxic. As CCA impregnated wood is still today used for many construction purposes, a monitoring of these metal ions is of great environmental importance. Thick-target PIXE is a powerful method for the determination of trace metals in wood. The TTPIXE method enabled study of variations of the elemental concentrations in lumber treated with CCA impregnation solution. Distribution patterns were obtained for both naturally occurring elements and elements introduced in the treatment process. During the impregnation process a desorption of e.g. alkali metal ions takes place from the wood. The sensitivity of the method is improved by dry ashing of the samples prior to PIXE analysis. The TTPIXE method was calibrated and validated using international certified reference materials (CRM) based on wood material

  9. The non-destructive identification of early Chinese porcelain by PIXE

    International Nuclear Information System (INIS)

    Cheng, H.S.; Zhang, Z.Q.; Zhang, B.; Yang, F.J.

    2004-01-01

    PIXE is used for the non-destructive differentiation of early precious Chinese blue and white porcelain made in Yuan (AD 1206-1368), Ming (AD 1368-1644) Dynasty in Jingdezhen from imitations. Also, ancient celadon made in Song Dynasty (AD 960-1279) is identified by measuring the trace elements contained in the glazes

  10. The non-destructive identification of early Chinese porcelain by PIXE

    Science.gov (United States)

    Cheng, H. S.; Zhang, Z. Q.; Zhang, B.; Yang, F. J.

    2004-06-01

    PIXE is used for the non-destructive differentiation of early precious Chinese blue and white porcelain made in Yuan (AD 1206-1368), Ming (AD 1368-1644) Dynasty in Jingdezhen from imitations. Also, ancient celadon made in Song Dynasty (AD 960-1279) is identified by measuring the trace elements contained in the glazes.

  11. Application of the micro-PIXE technique for analyzing arsenic in biomat and lower plants of lichen and mosses around an arsenic mine site, at Gunma, Japan

    International Nuclear Information System (INIS)

    Ohnuki, T.; Sakamoto, F.; Kozai, N.; Samadfam, M.; Sakai, T.; Kamiya, T.; Satoh, T.; Oikawa, M.

    2002-01-01

    Microhabitats of bacteria (biomat) and lower plants, such as lichen and mosses, are known to accumulate hazardous elements. Since the concentration of hazardous elements in the environment is quite low, we have applied the in-air μ-PIXE (particle induced X-ray emission) system developed in the TIARA facility of JAERI, which has low concentration detection limit of ppm, to measure As, one of the hazardous elements, distributions in biomat, lichen and mosses observed around an abandoned As mine site in Gunma, Japan to elucidate the applicability of these biomat and lower plants as bio-indicators of As. Spatial distributions of As, Fe, Si and S in all biomat, lichen and moss collected within 3 m from the mine entrance indicate that As is localized, and is associated with silicate and Fe-containing compounds. In addition, the intensity ratio of peak area for As to Fe in μ-PIXE spectrum of the moss collected from the concrete wall at 3 m downstream of the mine water discharge position is different from those of the lower plants on the rock near the closed entrance, but is the same as that of biomat formed at the mine water discharge position. This indicates that As trapped by the moss on the concrete wall probably has the same origin as the biomat. It is concluded that application of μ-PIXE analysis to the measurement of As in the lower plants and biomat gives not only the distribution of the hazardous element of As, but also the information of the origin

  12. Advanced, enhanced HEX program for PIXE

    International Nuclear Information System (INIS)

    Lipworth, A.D.; Annegarn, H.J.; Kneen, M.A.

    1993-01-01

    The REX code and subsequent HEX code, originating at Florida State University, have been extensively used for PIXE spectra fitting. In 1989 we produce a renovated HEX package: WITS-HEX, enabling the original Fortran program to be more accessible to the PIXE community. We modernised the user interface by replacing the batch mode of operation with an integrated, menu-driven environment. We added the ability to edit support data files from within the program, provided detailed feedback during the fitting process and enhanced spectral plots using high resolution colour graphics. Our prototype also permitted the inclusion of many more peaks and absorption coefficients into the element library than the original HEX, permitting a more extensive element request list to be used during the fitting operation. We have now completed the second phase of the renewal of HEX. The man-machine interface has been upgraded to conform to the IBM SAA Common User Access (CUA) standard. This eliminated several of the sequential (modal) human-computer dialogues, replacing them with a single parallel system. The support utility used in WITS-HEX to convert the binary format of spectra captured using foreign data acquisition systems has been replaced by code to directly access data in ASCII format. The program is now equipped with context-sensitive help and a tutorial. The polynomial background mode has been supplemented by a digital filter model, eliminating the associated instability from the fitting process and other spectral features modelled. The program has been validated by comparing results with those obtained from the former versions: WITS-HEX and HEX. A demonstration version is available on request for evaluation purposes. (orig.)

  13. Lapis lazuli provenance study by means of micro-PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Re, Alessandro, E-mail: alessandro.re@to.infn.it [Dipartimento di Fisica Sperimentale, Universita di Torino, Via Giuria 1, 10125 Torino (Italy); INFN Sezione di Torino and Centre of Excellence ' Nanostructured Interfaces and Surfaces' , Universita di Torino, Via P. Giuria 1, 10125 Torino (Italy); Giudice, Alessandro Lo [Dipartimento di Fisica Sperimentale, Universita di Torino, Via Giuria 1, 10125 Torino (Italy); INFN Sezione di Torino and Centre of Excellence ' Nanostructured Interfaces and Surfaces' , Universita di Torino, Via P. Giuria 1, 10125 Torino (Italy); Angelici, Debora [Dipartimento di Fisica Sperimentale, Universita di Torino, Via Giuria 1, 10125 Torino (Italy); Calusi, Silvia; Giuntini, Lorenzo; Massi, Mirko [Dipartimento di Fisica, Universita and INFN Sezione di Firenze, Via Sansone 1, 50019 Sesto Fiorentino, Firenze (Italy); Pratesi, Giovanni [Dipartimento di Scienze della Terra and Museo di Storia Naturale, Universita di Firenze, Via G. La Pira 4, 50121 Firenze (Italy)

    2011-10-15

    In this paper we report about the micro-PIXE characterisation of lapis lazuli, for a provenance study of this semi-precious stone, used for glyptic as early as 7000 years ago. The final aim is to find markers permitting to identify the origin of the raw material coming from three quarries in regions of historical importance: Afghanistan, Pamir Mountains and Siberia. This may help to reconstruct trade routes, especially for ancient objects for which written testimonies are scanty or absent at all. Due to the heterogeneity of lapis lazuli we concentrate our attention on single phases instead of the whole stone; in particular we focused on two of the main phases: lazurite, responsible for the blue colour, and diopside, the most frequent accessory mineral. This study was preceded and completed by means of microanalysis with Scanning Electron Microscopy (SEM-EDX) and Cold-Cathodoluminescence (cold-CL) analysis. Despite the limited number of analysed samples, results are sufficient to exclude/suggest a few features as provenance markers, partly confirming what has been previously published in literature.

  14. Lapis lazuli provenance study by means of micro-PIXE

    International Nuclear Information System (INIS)

    Re, Alessandro; Giudice, Alessandro Lo; Angelici, Debora; Calusi, Silvia; Giuntini, Lorenzo; Massi, Mirko; Pratesi, Giovanni

    2011-01-01

    In this paper we report about the micro-PIXE characterisation of lapis lazuli, for a provenance study of this semi-precious stone, used for glyptic as early as 7000 years ago. The final aim is to find markers permitting to identify the origin of the raw material coming from three quarries in regions of historical importance: Afghanistan, Pamir Mountains and Siberia. This may help to reconstruct trade routes, especially for ancient objects for which written testimonies are scanty or absent at all. Due to the heterogeneity of lapis lazuli we concentrate our attention on single phases instead of the whole stone; in particular we focused on two of the main phases: lazurite, responsible for the blue colour, and diopside, the most frequent accessory mineral. This study was preceded and completed by means of microanalysis with Scanning Electron Microscopy (SEM-EDX) and Cold-Cathodoluminescence (cold-CL) analysis. Despite the limited number of analysed samples, results are sufficient to exclude/suggest a few features as provenance markers, partly confirming what has been previously published in literature.

  15. Trace elements in lake sediments measured by the PIXE technique

    International Nuclear Information System (INIS)

    Gatti, Luciana V.; Mozeto, Antonio A.; Artaxo, Paulo

    1999-01-01

    Lakes are ecosystems where there is a great potential of metal accumulation in sediments due to their depositional characteristics. Total concentration of trace elements was measured on a 50 cm long sediment core from the Infernao Lake, that is an oxbow lake of the Moji-Guacu River basin, in the state of Sao Paulo, Brazil. Dating of the core shows up to 180 yrs old sediment layers. The use of the PIXE technique for elemental analysis avoids the traditional acid digestion procedure common in other techniques. The multielemental characteristic of PIXE allows a simultaneous determination of about 20 elements in the sediment samples, such as, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr, Zr, Ba, and Pb. Average values for the elemental composition were found to be similar to the bulk crustal composition. The lake flooding pattern strongly influences the time series of the elemental profiles. Factor analysis of the elemental variability shows five factors. Two of the factors represent the mineralogical matrix, and others represent the organic component, a factor with lead, and another loaded with chromium. The mineralogical component consists of elements such as, Fe, Al, V, Ti, Mn, Ni, K, Zr, Sr, Cu and Zn. The variability of Si is explained by two distinct factors, because it is influenced by two different sources, aluminum-silicates and quartz, and the effect of inundation are different for each other. The organic matter is strongly associated with calcium, and also bounded with S, Zn, Cu and P. Lead and chromium appears as separated factors, although it is not clear the evidences for their anthropogenic origin. The techniques developed for sample preparation and PIXE analysis was proven as advantageous and provided very good reproducibility and accuracy

  16. Investigation of the mineral contents of some varieties of powder milk by pixe

    International Nuclear Information System (INIS)

    Ahmad, N.; Aejaz, S.M.H.; Naeem, A.; Shahnawaz, M; Saadat, S.

    2010-01-01

    Milk and milk products constitute an important ingredient of human nutrition all over the world. Macro mineral contents like sodium, potassium, calcium, phosphorus and micro mineral contents like iron, copper, zinc, manganese of some varieties of powder milk available in the local market have been investigated by Proton Induced X-Ray Emission (PIXE). These elements are essential for the optimal functioning of various chemical processes taking place in the human body. Any toxic element present in milk can also be detected simultaneously. PIXE is a powerful and universal elemental analysis technique with high detection sensitivity for elements with Z> 11 in the periodic table. The technique is non-destructive and may be applied to samples as small as a cell to a large painting. (author)

  17. Regional-interstate site-review procedure: low-level radioactive waste disposal facility

    International Nuclear Information System (INIS)

    1983-09-01

    The attributes of the Southern States Energy Board (SSEB) enable it to view federal/state interface problem areas from a perspective that can be uniquely constructive. The board is sensitive to the interests of both federal and state levels of government since it is composed of member states with common regional interests and confirmed by federal legislative action. It has been most effective when exercising a leadership role in finding procedures and practices that use the resources of both levels of government that are mutually supportive and nonduplicative. SSEB began an NRC-funded effort in that direction related to nuclear power plant siting in June 1975, entitled Regional-Interstate Nuclear Facility Siting Procedure Demonstration Project. SSEB approached the problem by working with interested states to analyze various elements of the licensing process, in particular with NEPA review procedures for interstate coordination where potential impacts extend beyond a single state and where the facility serves an interstate or regional need. SSEB also served as a catalyst in the development of a region-wide nuclear facility siting procedure that could improve the effectiveness and timeliness of the regulatory process

  18. Comparison of elemental quantity by PIXE and ICP-MS and/or ICP-AES for NIST standards

    International Nuclear Information System (INIS)

    Saitoh, K.; Sera, K.; Gotoh, T.; Nakamura, M.

    2002-01-01

    Urban particulate matter (SRM 1648), Buffalo River sediment (SRM 2704) and pine needle (SRM 1575) standard reference materials prepared by the National Institute of Standards and Technology (NIST, USA) were analyzed by three multi-element analysis methods, i.e., particle induced X-ray emission (PIXE), inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES); values determined by those analysis methods were compared with certified and/or non-certified values of NIST samples. Values determined by PIXE were 70-120% relative to certified and/or non-certified values of NIST samples except for Co in the urban particulate matter, for V and Co in Buffalo River sediment and for Ni and Br in the pine needles samples. In particular, Al, K, Ca, Cr, Mn, Fe, Cu, Zn and Pb were 85-110% in all samples. On the other hand, Na and Fe values determined by ICP-MS were very much different from the certified values in all samples, but the other elements were 70-120%. As for ICP-AES, all elements except for Na were 80-100% in all samples. Comparing the values determined by PIXE and those determined by ICP-MS and/or ICP-AES, there was a slight difference between the samples, but the range was 75-120% except for Na, V, Fe and Co determined by ICP-MS and Na determined by ICP-AES, which was generally consistent with PIXE

  19. Studies in the compartmentalization of trace elements in the blood of patients with sickle cell anaemia using PIXE technique

    International Nuclear Information System (INIS)

    Ojo, J.O.; Oluwole, A.F.; Durosinmi, M.A.; Arsed, W.; Akanle, O.A.; Spyrou, N.M.

    1993-01-01

    Concentrations of trace elements in the whole blood, plasma and erythrocytes of 77 individuals (20 carrying the HbSS genotype, 21 with HbAS and 36 with HbAA) were determined using a PIXE facility employing a 2 MeV proton beam. Up to 16 elements were detected in some or all of the samples. The skewness of elemental distribution was measured for each element in the three bloodflow compartments. Most of the essential elements, apart from selenium were distinctly packed in either the erythrocytes or the plasma. Results of the t-test employed to compare elemental values between sickle cell subjects and matched controls show similar patterns in the three compartments for some of the elements. The results are compared with previous work using INAA. (orig.)

  20. Radonclose - the system of Soviet designed regional waste management facilities

    International Nuclear Information System (INIS)

    Horak, W.C.; Reisman, A.; Purvis, E.E. III.

    1997-01-01

    The Soviet Union established a system of specialized regional facilities to dispose of radioactive waste generated by sources other than the nuclear fuel cycle. The system had 16 facilities in Russia, 5 in Ukraine, one in each of the other CIS states, and one in each of the Baltic Republics. These facilities are still being used. The major generators of radioactive waste they process these are research and industrial organizations, medical and agricultural institution and other activities not related to nuclear power. Waste handled by these facilities is mainly beta- and gamma-emitting nuclides with half lives of less than 30 years. The long-lived and alpha-emitting isotopic content is insignificant. Most of the radwaste has low and medium radioactivity levels. The facilities also handle spent radiation sources, which are highly radioactive and contain 95-98 percent of the activity of all the radwaste buried at these facilities

  1. Technical, economic and institutional aspects of regional spent fuel storage facilities

    International Nuclear Information System (INIS)

    2005-11-01

    A particular challenge facing countries with small nuclear programmes is the preparation for extended interim storage and then disposal of their spent nuclear fuel. The costs and complications of providing for away-from-reactor storage facilities and/or geological repositories for relatively small amounts of spent fuel may be prohibitively high, motivating interest in regional solutions. This publication addresses the technical, economic and institutional aspects of regional spent fuel storage facilities (RSFSF) and is based on the results of a series of meetings on this topic with participants from IAEA Member States. Topics discussed include safety criteria and standards, safeguards and physical protection, fuel acceptance criteria, long term stability of systems and stored fuel, selection of site, infrastructure aspects, storage technology, licensing, operations, transport, decommissioning, as well as research and development. Furthermore the publication comprises economic, financial and institutional considerations including organizations and legal aspects followed by political and public acceptance and ethical considerations. Approaches and processes for implementation are discussed, as well as the overall benefits and risks of implementing a regional facility. It is illustrated that implementing a RSFSF facility would involve simultaneously addressing a wide range of diverse challenges. The appendix to this report tabulates the numerous issues that have been touched upon in the study. It appears, however, from the discussions that the challenges can in principle be met; the RSFSF concept is technically feasible and potentially economically viable. The technical committees producing this report did not identify any obvious institutional deficiencies that would prevent completion of such a project. Storing spent fuel in a few safe, reliable, secure facilities could enhance safeguards, physical protection and non-proliferation benefits. The committee also

  2. PIXE analysis of western han dynasty ancient glasses unearthed in Yangzhou city

    International Nuclear Information System (INIS)

    Li Qinghui; Gu Donghong; Gan Fuxi; Zhang Bin; Ma Bo; Cheng Huansheng

    2003-01-01

    Chemical composition analysis is one of the most important research aspects to provide scientific proof for the technical origin and development of Chinese ancient glass. Proton induced X-ray emission (PIXE) technique is a kind of multi-element quantitative analysis method with high sensitivity and without destruction of samples. Chemical composition of the Western Han dynasty glass garment flakes, which were excavated from Yangzhou city, was analyzed by PIXE, quantitatively. It was found that these glass flakes were attributed to PbO-BaO-SiO 2 glass originated in China. These flakes all consist of a glass core and a corroded outer layer with different thickness. There are relatively higher PbO, P 2 O 5 and CaO, while much lower BaO and SiO 2 in the corroded layers than in the glass cores. The experimental results were discussed

  3. PIXE analysis of museum soapstone sculptures from Esie, south west Nigeria

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Olarewaju, V.O.; Onabajo, O.

    1989-05-01

    The PIXE technique was employed for the study of Esie museum stone sculptures using 2.55 MeV protons from the 3 MeV tandem accelerator (NEC 3 UDH) in Lund, coupled with the geological and archaeological findings. The aim is to elucidate and decipher the prodigious but rather enigmatic and bewildering stone sculptures. PIXE results show that the composition of the stone sculptures are 40.69% talc-tremolite schist, 30.88% talc-chlorite schist, 15.20% talc-tremolite-anthophyllite schist and 13.24% talc-amphibolite schist. Thus the composition of Esie sculptures are found to be the same with the locally available talc-schists present around Esie. The geological evidence (mineralogical results) corroborated this as there was no textural or mineralogical difference between the talc-bearing country rock (outcrop) in Esie and the museum soapstone samples studied. Consequently, there is a very high probability that the sculptures were carved using the locally available talc-schists. (author). 7 refs, 4 figs, 2 tabs

  4. External PIXE analysis of an Iranian 15th century poetry book

    Energy Technology Data Exchange (ETDEWEB)

    Kakuee, Omidreza, E-mail: okakuee@aeoi.org.ir [Nuclear Science Research School, NSTRI, P.O. Box 14395-836, Tehran (Iran, Islamic Republic of); Fathollahi, Vahid; Oliaiy, Parvin; Lamehi-Rachti, Mohammad [Nuclear Science Research School, NSTRI, P.O. Box 14395-836, Tehran (Iran, Islamic Republic of); Taheri, Raziyeh; Jafarian, Hosseinali A. [The Library, Museum and Documentation Center of the Islamic Republic of Iran Parliament, Tehran (Iran, Islamic Republic of)

    2012-02-15

    The paints of illumination, ink and paper of an Iranian poetry manuscript originally belonging to 15th century but partly restored about 300 years ago are characterized by external PIXE. The technique was employed to determine the elemental composition of different inks and paints applied in the text and illumination as well as the paper of both the original masterpiece and the restored parts in order to evaluate the quality of restoration processes. The X-ray spectra were collected by a Si(Li) X-ray detector placed at a scattering angle of 135 Degree-Sign while the beam charge was indirectly measured through the Ar K{sub {alpha}} X-ray yield originated from the irradiation of in-air Argon. By analysis of the collected PIXE spectra, concentration of different elements present in closely matched colored areas in the original and restored illuminations were compared. In the same way, the origin of colored pigments and black ink in the original and restored illuminations and texts are inferred.

  5. External PIXE analysis of an Iranian 15th century poetry book

    International Nuclear Information System (INIS)

    Kakuee, Omidreza; Fathollahi, Vahid; Oliaiy, Parvin; Lamehi-Rachti, Mohammad; Taheri, Raziyeh; Jafarian, Hosseinali A.

    2012-01-01

    The paints of illumination, ink and paper of an Iranian poetry manuscript originally belonging to 15th century but partly restored about 300 years ago are characterized by external PIXE. The technique was employed to determine the elemental composition of different inks and paints applied in the text and illumination as well as the paper of both the original masterpiece and the restored parts in order to evaluate the quality of restoration processes. The X-ray spectra were collected by a Si(Li) X-ray detector placed at a scattering angle of 135° while the beam charge was indirectly measured through the Ar K α X-ray yield originated from the irradiation of in-air Argon. By analysis of the collected PIXE spectra, concentration of different elements present in closely matched colored areas in the original and restored illuminations were compared. In the same way, the origin of colored pigments and black ink in the original and restored illuminations and texts are inferred.

  6. PIXE/RBS as a tool to study cementitious materials: Application to the dynamic leaching of concrete

    International Nuclear Information System (INIS)

    Llorente, I.; Castellote, M.; Gonzalez-Arrabal, R.; Ynsa, M.D.; Munoz-Martin, A.; Viedma, P.G. de; Castillo, A.; Martinez, I.; Andrade, C.; Zuloaga, P.; Ordonez, M.

    2009-01-01

    The suitability of the application of Ion Beam Analysis (IBA) techniques such as Particle Induced X-ray Emission spectrometry (PIXE) and Rutherford Backscattering Spectrometry (RBS) to elemental depth profiling in concrete is analysed, studying hardened samples of concrete prior to and after a dynamic leaching test. A calibration of the data has been done by comparing the results obtained by IBA techniques with those obtained by Chemical and Thermogravimetric Analysis (TG/DTA). From PIXE and RBS data relevant information about the migration of minor elements, within the concrete matrix after leaching is obtained.

  7. PIXE/RBS as a tool to study cementitious materials: Application to the dynamic leaching of concrete

    Energy Technology Data Exchange (ETDEWEB)

    Llorente, I., E-mail: irene@cenim.csic.e [Centro Nacional de Investigaciones Metalurgicas (CENIM-CSIC), Avda Gregorio del Amo, 8, 28040 Madrid (Spain); Castellote, M. [Instituto de Ciencias de la Construccion ' Eduardo Torroja' (IETcc-CSIC), Serrano Galvache, 4, 28033 Madrid (Spain); Gonzalez-Arrabal, R. [Parque Cientifico de Madrid, Campus de Cantoblanco, Einstein 13, 28049 Madrid (Spain); Ynsa, M.D.; Munoz-Martin, A. [Centro de Microanalisis de Materiales (CMAM), Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Viedma, P.G. de; Castillo, A.; Martinez, I.; Andrade, C. [Instituto de Ciencias de la Construccion ' Eduardo Torroja' (IETcc-CSIC), Serrano Galvache, 4, 28033 Madrid (Spain); Zuloaga, P.; Ordonez, M. [Empresa Nacional de Residuos Radiactivos, S.A. (ENRESA), Emilio Vargas, 7, 28043 Madrid (Spain)

    2009-12-15

    The suitability of the application of Ion Beam Analysis (IBA) techniques such as Particle Induced X-ray Emission spectrometry (PIXE) and Rutherford Backscattering Spectrometry (RBS) to elemental depth profiling in concrete is analysed, studying hardened samples of concrete prior to and after a dynamic leaching test. A calibration of the data has been done by comparing the results obtained by IBA techniques with those obtained by Chemical and Thermogravimetric Analysis (TG/DTA). From PIXE and RBS data relevant information about the migration of minor elements, within the concrete matrix after leaching is obtained.

  8. The proton induced X-ray emission (PIXE) for the quantitative analysis of elements in thin samples, in surface layers of thick samples, and in aerosol filters

    International Nuclear Information System (INIS)

    Waetjen, U.

    1983-01-01

    The PIXE analysis method for the determination of elements in thick samples was investigated. The text of the present thesis is arranged under the following headings: physical fundamentals and measuring equipment, quantitative analysis of thin samples, matrix effects at the PIXE analysis of thick samples, matrix correction methods, analysis of 'infinite thick' model substances, PIXE analysis of aerosol filters. (GSCH)

  9. Determination of trace elements in plant samples using XRF, PIXE and ICP-OES techniques

    International Nuclear Information System (INIS)

    Ahmed, Hassan Elzain Hassan

    2014-07-01

    The purpose of this study is to determine trace element concentration (Ca, Cu, Cr, K,Fe, Mn,Sr, and Za) in some sudanese wild plants namely, Ziziphus Abyssinica and Grewia Tenax. X-ray fluorescence ( X RF), particle-induced x-ray emission ( PIXE) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) techniques were used for element determination. A series of plants standard references materials were used to check the reliability of the different employed techniques as well as to estimate possible factors for correcting the concentration of some elements that deviated significantly from their actual concentration. The results showed that, X RF, PIXE and ICP-OES are equally competitive methods for measuring Ca,K, Fe, Sr and Zn elements. Unlikely to ICP-OES seems to be superior techniques tend to be appropriate methods for Cu determination in plant samples however, for Mn element PIXE and ICP-OES are advisable techniques for measuring this element rather than X RF method. On the other hand, ICP-OES seems to be the superior techniques over PIXE and X RF methods for Cr and Ni determination in plant samples. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia Tenax than collected from different location. Most of measured elements showed similarity indicating there is no significant impact of locations on the difference of element contents. In addition, two plants with different genetic families namely, Ziziphus Spina Christi and Ziziphus Abyssinica were collected from the same location and screened for their trace element content. It was found that there were no difference between the two plants for Ca, K, Cu, Fe, and Sr element. However, significant variations were observed for Mn and Zn concentrations implying the possibility of using of those two elements for plant taxonomy purposes.(Author)

  10. Improved PIXE analysis of micro- and trace elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Ciortea, C.; Fluerasu, D.; Enescu, S. E.; Preoteasa, E.

    2001-01-01

    Due to the interactions occurring at the solid-solid and solid-liquid interfaces of a tooth's filling, the mineral elements of the restorative composite may induce a complex response of the organism. To study such problems, sensitive surface trace element analysis is required. Particle-induced X-ray emission (PIXE) has a detection limit one order of magnitude lower than XRF and has been used for hard dental tissues, but not yet for dental composites. We evaluated the potential of PIXE in a study of ten types of composites used in restorative dentistry, some of them with two color shades each. The samples were prepared as described for XRF. The measurements were performed with 3 MeV protons from a van de Graaff tandem linear accelerator, using a hyper pure Ge detector and collecting the spectra for 1.5-4 hours. The spectra were processed with the program Leone. The proton route in the sample calculated with the Trim program (∼ 50-100 μm) exceeded the size of mineral particles (0.02-30 μm), thus granularity did not affect the analysis. The PIXE analysis detected Z ≥ 19 elements in all composites, and Z≥14 elements in only one low Z material. PIXE detected generally the same dominant elements, but many more trace elements than XRF. Thus both Charisma (Kulzer) and Pekafill (Bayer) contained Ba as the major element, but trace elements were Ni, Zn, In, in the first, and Fe, Cu, Zn, Sr, Ag in the second. In other glass- and ceramics-based materials we found: Ca, Zr, Ba, Yb and traces of Sr, In, and possibly Ti in Tetric Ceram and in Ariston (both from Vivadent); Ca, Zr, Ba, Hf, possibly Mn, and traces of Ni, Ho, Ti, Fe, Cr in Valux Plus (3M Dental); Sr, Ba (major), K, Fe, Mn (minor), and traces of Ni, Zn, In, in F2000 Compomer (3M Dental); Ba (major) and traces of Fe, Ni, Sr in Surefil (Dentsply). In quartz-based materials we detected: Si, Ca, Ti, Fe and traces of K, Cl, Cr, Ni, Cu, Zn in Evicrol (Spofa); low and trace levels of Ca, Ti, Cr, Mn, Fe, Cu in

  11. Improvement of detection limits of PIXE by substrate signal reduction

    International Nuclear Information System (INIS)

    Beaulieu, S.; Nejedly, Z.; Campbell, J.L.; Edwards, G.C.; Dias, G.M.

    2002-01-01

    Limits of detection (LODs) for aerosol samples collected using PIXE International cascade impactors, were improved approximately 50% after reducing the cross-sectional area of the analytical beam based on results obtained from microscope photographs of aerosol deposits. Improvements in LODs were most noticeable for selected elements collected on the smaller stages of the impactor (stages 1-3)

  12. USEPA Geospatial Metadata EPA Region 2 All Regulated Facilities GIS layer PUB.

    Data.gov (United States)

    U.S. Environmental Protection Agency — This ArcGIS 10.2 point feature class (All Regulated Facilities [R2] Public contains a unique record for every EPA Regulated Facility in EPA Region 2 (NYS, NJ, Puerto...

  13. PIXE analysis for bioaccumulation studies of trace elements

    International Nuclear Information System (INIS)

    Iwata, Y.; Satoh, A.; Sasaki, Y.; Ito, R.; Kuramachi, K.

    2005-01-01

    Bioaccumulation by micro-alga in the ocean was simulated in nutritive seawater containing known amounts of trace metals, and the concentration factors for Fe, Zn and Cd were measured by PIXE. Trace transition metals in nearshore seawater were removed by Chelex-100. Then a culture solution was prepared by adding known amounts of trace metals and nutritive salts to the purified seawater. Marine micro-algae (Nannochloropsis sp., and Phaeodactylum sp.,) were purely cultured in the culture solution. An interested metal ion was added to the culture solution (0.01-5.0 mg/l). Alga in 10 ml of the culture solution was collected on a polycarbonate filter (pore size: 1.0 ) by suction filtration and subjected to 2.9 MeV proton bombardment. Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Zn and Cd were simultaneously determined. PIXE multi-element analysis was possible using less than 1 mg of analytical sample. The quantity of the metal in the alga was increased in proportion to the concentration in the culture solution. The concentration factors for Zn, Fe and Cd were measured, e.g., 10200 ± 300 ml/g to Zn for Phaeodactylum. The trend of the affinity for the trace metals in the case of Nannochloropsis was Fe 3+ > Zn 2+ > Pb 2+ > Cd 2+ . (author)

  14. Optimized readout configuration for PIXE spectrometers based on Silicon Drift Detectors: Architecture and performance

    International Nuclear Information System (INIS)

    Alberti, R.; Grassi, N.; Guazzoni, C.; Klatka, T.

    2009-01-01

    An optimized readout configuration based on a charge preamplifier with pulsed-reset has been designed for Silicon Drift Detectors (SDDs) to be used in Particle Induced X-ray Emission (PIXE) measurements. The customized readout electronics is able to manage the large pulses originated by the protons backscattered from the target material that would otherwise cause significant degradation of X-ray spectra and marked increase in dead time. In this way, the excellent performance of SDDs can be exploited in high-quality proton-induced spectroscopy of low- and medium-energy X-rays. This paper describes the designed readout architecture and the performance characterization carried out in a PIXE setup with MeV proton beams.

  15. PIXE analysis of pre-colonial pottery from Sambaqui do Panaquatira

    International Nuclear Information System (INIS)

    Ikeoka, R.A.; Appoloni, C.R.; Rizzutto, M.A.; Silva, T.F.; Bandeira, A.M.

    2013-01-01

    Full text: The study of cultural heritage of ancient people through fossils, monuments and engines has fundamental importance in the construction of the memory of any society. Such knowledge can be acquired by researches in archaeological sites and the detailed study of the different kind of objects which can be found in these places. This work deals with objects from the Sambaqui of Panaquatira located in Sao Luis do Maranhao (Brazil). Ancient civilizations that inhabited that territory were characterized as fishing populations - catchers - hunters and ceramists. From a selection of 95 pottery fragments of surface; 5 to 10 cm; 20 to 30 cm; 40 to 50 cm; 65 to 70 cm; 80 to 90 cm; 90 to 100 cm; 130 to 140 cm and 160 to 170 cm stratigraphic levels, a representative set was analyzed using Particle Induced X-ray Emission (PIXE) methodology. PIXE measurements were performed with an external beam setup with ~2.4 MeV proton beam in the LAMFI laboratory using three X-ray detectors, two Si-PIN detectors and one HPGe with standard spectrometry electronics; each spectrum was taken for 600s. The spectra analyses were performed with the Quantitative X-Ray Analysis Software (WinQXAS), distributed by International Atomic Energy Agency (IAEA). The elements Si, P, S, CI, K, Ca, Ti, Cr, Mn, Fe and Zn were identified in the different fragments. It was analysed the kind of applied treatment on the concave and convex sides in relation to the ceramic paste of the fragments. From the determination of the elemental composition of the fragments, it was possible to identify that the elements Ti, Mn, Fe and Zn are present in the fragments with larger amounts at concave and convex sides, compared to the ceramic paste, indicating a different surface treatment that leads to an enrichment of these elements. One fragment from the 20-25cm stratigraphy has a lighter colour region which is characterized by containing the highest concentration of the elements Ti, Ca, Ti, Cr and Mn. (author)

  16. PIXE analysis of pre-colonial pottery from Sambaqui do Panaquatira

    Energy Technology Data Exchange (ETDEWEB)

    Ikeoka, R.A.; Appoloni, C.R., E-mail: renatoikeoka@yahoo.com.br [Universidade Estadual de Londrina (CCE/UEL), PR (Brazil). Departamento de Fisica; Rizzutto, M.A.; Silva, T.F. [Universidade de Sao Paulo (LAMFI/USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Laboratorio de Analise de Materiais por Feixes Ionicos; Bandeira, A.M. [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Museu de Arqueologia e Etnologia

    2013-07-01

    Full text: The study of cultural heritage of ancient people through fossils, monuments and engines has fundamental importance in the construction of the memory of any society. Such knowledge can be acquired by researches in archaeological sites and the detailed study of the different kind of objects which can be found in these places. This work deals with objects from the Sambaqui of Panaquatira located in Sao Luis do Maranhao (Brazil). Ancient civilizations that inhabited that territory were characterized as fishing populations - catchers - hunters and ceramists. From a selection of 95 pottery fragments of surface; 5 to 10 cm; 20 to 30 cm; 40 to 50 cm; 65 to 70 cm; 80 to 90 cm; 90 to 100 cm; 130 to 140 cm and 160 to 170 cm stratigraphic levels, a representative set was analyzed using Particle Induced X-ray Emission (PIXE) methodology. PIXE measurements were performed with an external beam setup with ~2.4 MeV proton beam in the LAMFI laboratory using three X-ray detectors, two Si-PIN detectors and one HPGe with standard spectrometry electronics; each spectrum was taken for 600s. The spectra analyses were performed with the Quantitative X-Ray Analysis Software (WinQXAS), distributed by International Atomic Energy Agency (IAEA). The elements Si, P, S, CI, K, Ca, Ti, Cr, Mn, Fe and Zn were identified in the different fragments. It was analysed the kind of applied treatment on the concave and convex sides in relation to the ceramic paste of the fragments. From the determination of the elemental composition of the fragments, it was possible to identify that the elements Ti, Mn, Fe and Zn are present in the fragments with larger amounts at concave and convex sides, compared to the ceramic paste, indicating a different surface treatment that leads to an enrichment of these elements. One fragment from the 20-25cm stratigraphy has a lighter colour region which is characterized by containing the highest concentration of the elements Ti, Ca, Ti, Cr and Mn. (author)

  17. Micro-SR-XRF and micro-PIXE studies for archaeological gold identification - The case of Carpathian (Transylvanian) gold and of Dacian bracelets

    International Nuclear Information System (INIS)

    Constantinescu, B.; Bugoi, R.; Cojocaru, V.; Radtke, M.; Calligaro, T.; Salomon, J.; Pichon, L.; Roehrs, S.; Ceccato, D.; Oberlaender-Tarnoveanu, E.

    2008-01-01

    Trace-elements are more significant for provenancing archaeological metallic artifacts than the main components. For gold, the most promising elements are platinum group elements (PGE), Sn, Te, Sb, Hg and Pb. Several small fragments of natural Transylvanian gold - placer and primary - were studied by using micro-PIXE technique at the Legnaro National Laboratory AN2000 microbeam facility, Italy and at the AGLAE accelerator, C2RMF, Paris, France and by using micro synchrotron radiation X-ray fluorescence (micro-SR-XRF) at BESSY synchrotron, Berlin, Germany. The goal of the study was to identify the trace-elements, especially Sn, Sb and Te. A spectacular application to five Dacian gold bracelets authentication is presented (Sn and Sb traces)

  18. Study on the proton-induced X-ray emission(PIXE) using external proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, M. Y.; Yoon, J. C.; Park, K. J. [Seoul Natioanl University, Seoul (Korea, Republic of)

    2008-04-15

    We intend to develop a system that can extract a proton beam into air for a qualitative, and quantitative PIXE analysis up to ppm(percent per million) composition. When such an R and D is accomplished, first it is possible to get equipped with a system for PIXE and PIGmE, second, it is possible to contribute to an academic progress by the study for physical properties of matter through an nuclear science methods when the comparison between the measurement and the calculated quantities, and third, it is possible to contribute to a multi-disciplinary researches by the measurements of the samples for which it is hard to get the SRM for the samples. We intend to develop methods to measure the beam current for an air-borne proton beam, and to minimize the energy and current loss of the beam. We intend to acquire a set of PIXE data for rare-earth metals and transient metals, to form a basic database for the analysis for various samples for which it is hard to get the SRM. Developed PIXE beamline can extract the beam diameter up to 5mm, and beam intensity in the range 0.5nA to 10nA variable. sustaining the vacuum better than 10{sup -6} mtorr. Necessary detection system and methodology are complete. As the application of the present research achievements, we studied the analysis of aerosol composition, the appraisal of the cultural heritages, and a feasibility study for a proton beam writing. It is expected to become possible to analyse the compositions of the gems, the elemental compositions of the food, the discrimination of the traditional ink and the modern ink on the documents, the evaluation of the documents by the analysis of the elemental composition of the stamps, The analysis of the paper with respect to the date and the quality, the analysis of the color, and the core bored samples

  19. Grain-size effects on PIXE and INAA analysis of IAEA-336 lichen reference material

    Science.gov (United States)

    Marques, A. P.; Freitas, M. C.; Wolterbeek, H. Th.; Verburg, T. G.; De Goeij, J. J. M.

    2007-02-01

    IAEA-336 lichen certified reference material was used to compare outcomes from INAA and PIXE elemental analyses, in relationship with grain size. The IAEA material (grain size lichen reference material's particle size distribution follows a bimodal distribution, which is turning more and more monomodal after further fine sieving. Replicates of each fraction were analysed by INAA and PIXE. Results for Cl, K, Mn, Fe and Zn by both techniques were compared by application of z-values tested against the criterion ∣ z∣ limited amount of lichen material as "seen" in the PIXE analysis and the grain size distribution in the lichen material were no causes of measurable differences between the results of both techniques. However, fractionation into smaller grain sizes showed to be associated with lower element content, for Na, Cl, K, Mn and Sr even up to a factor of 2. The observed increases of the proportion of algae in the smaller grain-size fractions and the possible accumulation capacity for certain elements in the fungal part of the lichen may explain the observed phenomenon. The sieving process and consequently the discarding of part of the material have lead to a change of the properties of the original sample, namely algae/fungus percentage and elemental contents.

  20. PIXE analysis of trace elements in cetacean teeth

    International Nuclear Information System (INIS)

    Mitani, Yoko; Arai, Nobuaki; Sakamoto, Wataru; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in teeth of two species of cetaceans, sperm whale (Physeter microcephalus) and pantropical spotted dolphin (Stenella attenuata). The analyses were performed along with the growth layer of the teeth, which is formed annually, suitable for age determination. Mn, Fe, Cu, Zu and Sr were detected in the teeth of sperm whale and pantropical spotted dolphin. Among these trace elements, gradual increase was observed for Zn/Ca ratio in the sperm whale's teeth. (author)

  1. The combined application of PIXE analysis and thermoluminescence (TL) dating for elucidating the origin of iron manufacturing in Japan

    International Nuclear Information System (INIS)

    Hagihara, N.; Miono, S.; Chengzhi, Z.; Nakayama, Y.; Hanamoto, K.; Manabe, S.

    1999-01-01

    For elucidating the origin of iron manufacturing in Japan, the usefulness of PIXE analysis was reconfirmed and a new technique of thermoluminescence (TL) dating was applied. Through reproducing experiments of iron manufacturing and forging, PIXE analysis was tested for classifying the iron slag produced from these two different process. The TL dating method was improved for experiments with the iron manufacturing furnace, burnt at high temperature (about 1300 K) and irradiated with relatively low dose. Utilizing PIXE analysis, the iron manufacturing furnace can be distinguished from the older forging furnace used for the imported iron plate. Adopting TL dating, the oldest iron manufacturing furnace can be found out. Some ancient samples in Japan were used as a test of this combined application, and the results were positive, thus proving the suitability of the method

  2. Analysis of tree samples from an acidic and a limed environment by means of PIXE

    International Nuclear Information System (INIS)

    Pernestaal, K.; Li, Hong-Ko; Jonsson, B.; Haellgren, J.-E.

    1991-01-01

    Three tree core samples of Norway spruce (Picea Abies) have been analysed by PIXE. The concentration profiles for 17 elements heavier than sodium have been determined by means of one PIXE measurement every 2 mm along the samples. The samples were collected at Faexboda, an experimental area north of Uppsala where artificially acidified and limed environmental experiments are made. One sample from each of an acidified, a limed and a reference area has been collected. The main interest is focused on potassium, calcium, manganese, iron, copper and zinc. All three samples have about the same concentration profile in the heartwood. Large differences are observed in the sapwood. In the sample from the limed area the calcium content is much higher and the iron and chromium contents are lower than in the sample from the reference area. In the sample from the acidified area the calcium and potassium contents are lower and the manganese, iron and chromium contents are much higher than in the sample from the reference area. The observed concentration profiles of trace elements in trees indicate that changes in the environment due to acidification can be quantified at an early stage by means of PIXE. (author)

  3. Comparison of a Commonwealth-initiated regional radiation oncology facility in Toowoomba with a Queensland Health facility

    International Nuclear Information System (INIS)

    Poulsen, M.; Ramsay, R.; Gogna, K.; Middleton, M.; Martin, J.; Khoo, E.; Wong, W.; McQuitty, S.; Walpole, E.; Fairweather, R.

    2010-01-01

    The aim was to compare a private Commonwealth-initiated regional radiation oncology facility in Toowoomba with a Queensland Health facility (QHF) in Brisbane. The comparison concentrated on staffing, case mix and operational budgets, but was not able to look at changes in access to services. Data were collected from the two facilities from January 2008 to June 2008 inclusive. A number of factors were compared, including case mix, staffing levels, delay times for treatment, research, training and treatment costs. The case mix between the two areas was similar with curative treatments making up just over half the work load in both centres and two-thirds the work being made up of cancers of breast and prostate. Staffing levels were leaner in Toowoomba, especially in the areas of nursing, administration and trial coordinators. Research activity was slightly higher in Toowoomba. The average medicare cost per treatment course was similar in both centres ($5000 per course). Total costs of an average treatment including patient, State and Commonwealth costs, showed a 30% difference in costing favouring Toowoomba. This regional radiation oncology centre has provided state-of-the-art cancer care that is close to home for patients living in the Darling Downs region. Both public and private patients have been treated with modest costs to the patient and significant savings to QH. The case mix is similar to the QHF, and there has been significant activity in clinical research. A paperless working environment is one factor that has allowed staffing levels to be reduced. Ongoing support from Governments are required if private facilities are to participate in important ongoing staff training.

  4. PIXE and ICP-AES comparison in evaluating the efficiency of metal extraction and analysis in aerosol samples

    Energy Technology Data Exchange (ETDEWEB)

    Rugi, F.; Becagli, S.; Ghedini, C.; Marconi, M.; Severi, M.; Traversi, R.; Udisti, R. [Dep. of Chemistry, University of Florence, Sesto F.no (Fl) (Italy); Calzolai, G.; Chiari, M.; Lucarelli, F.; Nava, S. [Dep. of Physics and Astronomy , University of Florence and INFN, Sesto F. no (Fl) (Italy)

    2013-07-01

    Full text: A recent EU regulation (EN 149022005) requests the quantification of selected metals in the atmospheric particulate by mineralization with H{sub 2}0{sub 2} and HN0{sub 3} in microwave oven.This method might possibly conflict with the determination of the total metal content. In fact, the more the aerosol is enriched in crustal elements the more the difference in the two methods are expected, since the H{sub 2}0{sub 2}+ HN0{sub 3}, extraction is not reliable for metals in silicate form. In order to evaluate the extracted fraction, PIXE and ICP-AES measurements were carried out on the two halves of a series of PM10 and PM2.5 samples collected on Teflon filters in an urban site in the surrounding of Florence (Italy). An ICP-AES (Inductively Coupled Plasma -Atomic Emission Spectroscopy) method was optimized by an ultrasound nebuliser (CETAC 5000 AT+), in order to improve reproducibility and detection limit. In these conditions, it was possible quantifying AI, As, Cr, Cu, Fe, Mn, Ni, Pb and Vatsub-ppb levels. PIXE analysis using the external beam set-up at LABEC and a 3 MeV proton beam was carried out in order to measure the total elemental content of the metals. By comparing the ICP-AES and the PIXE results, a preliminary evaluation of the efficiency of the H{sub 2}0{sub 2} and HN0{sub 3} extraction method was performed. The obtained results (the mean values for the ICP-AES/PIXE ratio are reported in Table 1) show that the extraction procedure following the EN 14902 directive allows quantitative recoveries (80-120%, including the analytical uncertainties)for the majority of the analysed metals, especially for those mainly emitted by anthropic sources. This result points out that anthropic metals are present in the atmosphere as relatively available species (free metals, labile complexes, carbonates, oxides). On the contrary, lower recoveries were obtained for AI (mean value around 75%), a metal that has a relevant crustal fraction. Percentage of recovery of

  5. PIXE - a new method for elemental analysis

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1983-01-01

    With elemental analysis we mean the determination of which chemical elements are present in a sample and of their concentration. This is an old and important problem in chemistry. The earliest methods were purely chemical and many such methods are still used. However, various methods based on physical principles have gradually become more and more important. One such method is neutron activation. When the sample is bombarded with neutrons it becomes radioactive and the various radioactive isotopes produced can be identified by the radiation they emit. From the measured intensity of the radiation one can calculate how much of a certain element that is present in the sample. Another possibility is to study the light emitted when the sample is excited in various ways. A spectroscopic investigation of the light can identify the chemical elements and allows also a determination of their concentration in the sample. In the same way, if a sample can be brought to emit X-rays, this radiation is also characteristic for the elements present and can be used to determine the elemental concentration. One such X-ray method which has been developed recently is PIXE. The name is an acronym for Particle Induced X-ray Emission and indicates the principle of the method. Particles in this context means heavy, charged particles such as protons and a-particles of rather high energy. Hence, in PIXE-analysis the sample is irradiated in the beam of an accelerator and the emitted X-rays are studied. (author)

  6. PIXE and X-ray diffraction studies in ceramics of the Cuitzeo basin

    International Nuclear Information System (INIS)

    Bucio, L.; Ruvalcaba, J.L.; Filini, A.

    2005-01-01

    The methodology used to carry out the characterization of the ceramic material is based on the employment of two analytical techniques. The first one, X-ray diffraction (XRD), it is used to determine the composition of the present minerals and the general composition of the pastes. The second, X-ray emission induced by protons (PIXE), it is used to determine the composition of trace elements and bigger elements. The combined use of these techniques even allows to differ among ceramic pastes of very similar compositions. Although these techniques can be used in a non destructive way, in the case of ceramic studies it is required of taking a small quantity of sample of the potsherd, this is pulverized to homogenize the material and to carry out the XRD analysis. The same powder can be used to prepare a pellet and to carry out the PIXE analysis. (Author)

  7. Characterisation by PIXE RBS of metallic contamination of tissues surrounding a metallic prosthesis on a knee

    Science.gov (United States)

    Guibert, G.; Irigaray, J. L.; Moretto, Ph.; Sauvage, T.; Kemeny, J. L.; Cazenave, A.; Jallot, E.

    2006-09-01

    Implants used as biomaterials have to fulfill conditions of functionality, compatibility and sometimes bioactivity. There are four main families of biomaterials: metals and metal alloys, polymers, bioceramics and natural materials. Because of corrosion and friction in the human body, implants generate debris. This debris may develop toxicity, inflammation and prosthetic unsealing by osseous dissolution. Nature, size, morphology and amount of debris are the parameters influencing the tissue responses. In this paper, we characterised metallic contamination produced by knee prosthesis, composed with TiAl 6V 4 or Co-Cr-Mo alloys, into surrounding capsular tissue by depth migration, in vivo behaviour, content, size and nature of debris by PIXE (Particle Induced X-ray Emission) method associated with RBS (Rutherford Backscattering Spectroscopy). Debris distribution in the whole articulation is very heterogeneous. Debris migrates several thousand micrometers in tissues, with a characteristic decrease. Solid metallic particles of about micrometer size are found in the most polluted samples, in both alloys TiAl 6V 4 and Cr-Co-Mo. In the mean volume analysed by PIXE, the concentration mass ratios [Ti]/[V] and [Co]/[Cr] confirm the chemical stability of TiAl 6V 4 debris and show the chemical evolution of Cr-Co-Mo debris. Development of a protocol to prepare thin targets permits us to correlate PIXE and histological analysis in the same zone. The fibrous tissue (collagen fibres, fibroblasts) and macrophage cells are observed with optical microscope in polluted areas. This protocol could locate other pathologies in ppm contamination range, thanks to the great sensitivity of the PIXE method.

  8. Target characterization by PIXE, alpha spectrometry and X-ray absorption

    International Nuclear Information System (INIS)

    Kheswa, N.Y.; Papka, P.; Pineda-Vargas, C.A.; Newman, R.T.

    2011-01-01

    We report on the thickness and homogeneity characterization of thin metallic targets of Zr-96 by means of alpha absorption spectrometry, Particle Induced X-ray Emission (PIXE) and X-ray absorption. The target thicknesses determined by means of the above mentioned methods are critically compared. The thicknesses were determined before and after irradiation with a 70 MeV beam of 14 N ions.

  9. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    Energy Technology Data Exchange (ETDEWEB)

    Olabanji, S.O. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Makanju, O.V. [Drug Research and Production Unit, Faculty of Pharmacy, Obafemi Awolowo University (O.A.U.), Ile-Ife (Nigeria); Haque, A.M.I. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Buoso, M.C. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Ceccato, D. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro]|[Dipartimento di Fisica, Universita di Padova, I-35131 Padova (Italy); Cherubini, R. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro; Moschini, G. [Istituto Nazionale di Fisica Nucleare (INFN), Padua (Italy). Lab. Nazionali di Legnaro]|[Dipartimento di Fisica, Universita di Padova, I-35131 Padova (Italy)

    1996-06-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the {sup 19}F(p,p`{gamma}){sup 19}F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed. (orig.).

  10. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Haque, A.M.I.; Cherubini, R.

    1996-01-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the 19 F(p,p'γ) 19 F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed. (orig.)

  11. PIGE-PIXE analysis of chewing sticks of pharmacological importance

    Science.gov (United States)

    Olabanji, S. O.; Makanju, O. V.; Haque, A. M. I.; Buoso, M. C.; Ceccato, D.; Cherubini, R.; Moschini, G.

    1996-06-01

    PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the 19F(p, p'γ) 19F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed.

  12. Correction factor for hair analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Castro Faria, L.V. de; Paschoa, A.S.

    1980-01-01

    The application of the Particle Induced X-ray Emission (PIXE) technique to analyse quantitatively the elemental composition of hair specimens brings about some difficulties in the interpretation of the data. The present paper proposes a correction factor to account for the effects of the energy loss of the incident particle with penetration depth, and X-ray self-absorption when a particular geometrical distribution of elements in hair is assumed for calculational purposes. The correction factor has been applied to the analysis of hair contents Zn, Cu and Ca as a function of the energy of the incident particle. (orig.)

  13. PIXE analysis of ancient Chinese Changsha porcelain

    International Nuclear Information System (INIS)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Liu, T.Y.; Wu, C.M.; Chen, K.M.; Lin, S.S.

    1999-01-01

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed

  14. Correction factor for hair analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Castro Faria, L.V. de; Paschoa, A.S.

    1979-06-01

    The application of the Particle Induced X-ray Emission (PIXE) technique to analyse quantitatively the elemental composition of hair specimens brings about some difficulties in the interpretation of the data. The present paper proposes a correction factor to account for the effects of energy loss of the incident particle with penetration depth, and x-ray self-absorption when a particular geometrical distribution of elements in hair is assumed for calculational purposes. The correction factor has been applied to the analysis of hair contents Zn, Cu and Ca as a function of the energy of the incident particle.(Author) [pt

  15. PIXE analysis of ancient Chinese Changsha porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Liu, T.Y.; Wu, C.M.; Chen, K.M.; Lin, S.S

    1999-04-02

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed.

  16. PIXE analysis of ancient Chinese Changsha porcelain

    Science.gov (United States)

    Lin, E. K.; Yu, Y. C.; Wang, C. W.; Liu, T. Y.; Wu, C. M.; Chen, K. M.; Lin, S. S.

    1999-04-01

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed.

  17. Study of Z > 18 elements concentration in tree rings from surroundings forests of the Mexico Valley using external beam PIXE

    International Nuclear Information System (INIS)

    Calva-Vazquez, G.; Razo-Angel, G.; Rodriguez-Fernandez, L.; Ruvalcaba-Sil, J.L.

    2006-01-01

    The concentration of elements with Z > 18 is measured in tree rings from forests at the surroundings of the Mexico Valley: El Chico National Park (ECP) and Desierto de los Leones National Park (DLP). The analysis was done by simultaneous PIXE-RBS using an external proton beam on tree rings of Pine and Sacred fir (species Pinus montezumae and Abies religiosa, respectively). This study provides information about the elemental concentration in trees of those parks during the years from 1965 to 2003. Typical elements such as K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Sr and Pb were detected using PIXE technique while the wood matrix composition (mainly C and O) was determined by RBS. In general, elemental contents present large variations but concentrations oscillate around the mean value during this period of time. Nevertheless, the measurements showed some trends for Fe and Zn in the tree-rings elemental composition that may be correlated to recent volcanic activities in the region. The low Mn contents indicate soil acidification in DLP from 1968 and the forest decline in ECP during the last 15 years

  18. Micro-PIXE study of Ag in digestive glands of a nano-Ag fed arthropod (Porcellio scaber, Isopoda, Crustacea)

    International Nuclear Information System (INIS)

    Tkalec, Ziva Pipan; Drobne, Damjana; Vogel-Mikus, Katarina; Pongrac, Paula; Regvar, Marjana; Strus, Jasna; Pelicon, Primoz; Vavpetic, Primoz; Grlj, Natasa; Remskar, Maja

    2011-01-01

    Micro-proton induced X-ray emission (micro-PIXE) method was applied to study the micro-localization of silver (Ag) in digestive glands of a terrestrial arthropod (Porcellio scaber) after feeding on silver nanoparticles (nano-Ag) dosed food. The aim of our work was to assess whether feeding on nano-Ag results in the assimilation of silver (Ag) in digestive gland cells. To study micro-localization and elemental distribution of Ag, the animals were fed on food dosed with nanoparticles for 14 days under controlled laboratory conditions. At the end of the feeding exposure, the animals were dissected and digestive glands prepared for micro-PIXE analyses and TEM investigation. The results obtained by micro-PIXE documented high amounts of Ag inside S-cells of the digestive gland epithelium; however, TEM investigation did not show particle aggregates inside digestive gland cells. Also no adverse effect on feeding behavior was recorded what is a measure of toxic effects. We explain the presence of Ag inside the cells as a result of the assimilation of dissoluted Ag ions from ingested nano-Ag particles. Assimilation of excessive amounts of ingested metal ions in S-cells is a well known metal detoxification mechanism in isopods. We discuss the advantages of using micro-PIXE for the micro-localization of elements in biological tissue in studies of interactions between nanoparticles and biological systems.

  19. Silver surface enrichment controlled by simultaneous RBS for reliable PIXE analysis of ancient coins

    International Nuclear Information System (INIS)

    Beck, L.; Alloin, E.; Berthier, C.; Reveillon, S.; Costa, V.

    2008-01-01

    Evidence of silver surface enrichment of ancient silver-copper coins has been pointed out in the past years. Surface enrichment can be fortuitous or intentional. In this paper, we have investigated the cleaning procedures usually performed after excavation or in museums. We have shown that chemicals or commercial products routinely used dissolve preferentially the copper phase and consequently contribute to the silver surface enrichment. As a result, surface analyses such as PIXE or XRF can be strongly affected by this effect. By using simultaneously RBS and PIXE, it is possible to check through the silver surface enrichment and then select the reliable measurements, characteristic of the bulk composition. Results on coins recently discovered and mechanically or chemically cleaned are presented

  20. Elemental composition of skin tissue by PIXE and INAA analyses

    International Nuclear Information System (INIS)

    Hollands, R.; Spyrou, N.M.

    1997-01-01

    Hypertrophic scars are a particular type of scar that can form after any type of dermal injury. They are unsightly, red, elevated above normal skin level, itchy and painful. At present no-one knows why these scars form. Due to the differences between scar tissue and normal skin it was decided to analyse skin tissue which at a later date would be compared to scar tissue. Spit skin graft (epidermis) samples as well as full thickness skin (epidermis to dermis) tissue were analysed using PIXE and RBS with a 2 MeV proton beam. The epidermis was compared to the dermis to see if there were any variations between the two. In all the samples P, S, Cl, K, Ca, Fe, and Cd were detected and in a majority of the samples Zn and Ba were found, using PIXE. It was found that, between the epidermis and dermis, there was an significant increase in P in the epidermis in both full thickness and split skin graft samples. Complementary elemental analysis was also performed using neutron activation, and Br, Na and Zn were detected. (author)

  1. GPU-based online track reconstruction for the MuPix-telescope

    Energy Technology Data Exchange (ETDEWEB)

    Grzesik, Carsten [JGU, Mainz (Germany); Collaboration: Mu3e-Collaboration

    2016-07-01

    The MuPix telescope is a beam telescope consisting of High Voltage Monolithic Active Pixel Sensors (HV-MAPS). This type of sensor is going to be used for the Mu3e experiment, which is aiming to measure the lepton flavor violating decay μ→ eee with an ultimate sensitivity of 10{sup -16}. This sensitivity requires a high muon decay rate in the order of 1 GHz leading to a data rate of about 1 TBit/s for the whole detector. This needs to be reduced by a factor 1000 using online event selection algorithms on Graphical Processing Units (GPUs) before passing the data to the storage. A test setup for the MuPix sensors and parts of the Mu3e tracking detector readout is realized in a four plane telescope. The telescope can also be used to show the usability of an online track reconstruction using GPUs. As a result the telescope can provide online information about efficiencies of a device under test or the alignment of the telescope itself. This talk discusses the implementation of the GPU based track reconstruction and shows some results from recent testbeam campaigns.

  2. LePIX: First results from a novel monolithic pixel sensor

    International Nuclear Information System (INIS)

    Mattiazzo, S.; Battaglia, M.; Bisello, D.; Caselle, M.; Chalmet, P.; Demaria, N.; Giubilato, P.; Ikemoto, Y.; Kloukinas, K.; Mansuy, C.; Marchioro, A.; Mugnier, H.; Pantano, D.; Potenza, A.; Rivetti, A.; Rousset, J.; Silvestrin, L.; Snoeys, W.; Wyss, J.

    2013-01-01

    We present a monolithic pixel sensor developed in the framework of the LePIX project aimed at tracking/triggering tasks where high granularity, low power consumption, material budget, radiation hardness and production costs are a concern. The detector is built in a 90 nm CMOS process on a substrate of moderate resistivity. This maintains the advantages usually offered by Monolithic Active Pixel Sensors (MAPS), like a low input capacitance, having a single piece detector and using a standard CMOS production line, but offers charge collection by drift from a depleted region and therefore an excellent signal to noise ratio and a radiation tolerance superior to conventional undepleted MAPS. Measurement results obtained with the first prototypes from laser, radioactive source and beam test experiments are described. The excellent signal-to-noise performance is demonstrated by the capability of the device to separate the peaks in the spectrum of a 55 Fe source. We will also highlight the interaction between pixel cell design and architecture which points toward a very precise direction in the development of such depleted monolithic pixel devices for high energy physics

  3. PIXE analysis of sand and soil from Ulaanbaatar and Karakurum, Mongolia

    Science.gov (United States)

    Markwitz, A.; Barry, B.; Shagjjamba, D.

    2008-09-01

    Twenty-one sand and soil samples were collected at the surface from 22 to 25 June 2007 at sampling sites from Ulaanbaatar to Karakurum, Mongolia. The sand samples were collected from constantly changing sand dunes which may still contain salt from prehistoric oceans. The dry sand and soil samples were processed for PIXE and PIGE analyses. A clear division between soils and sand become apparent in the silicon results. Concentrations of all bulk elements in human habitation samples and of Si, Al, K and Fe in dry lake/flood plain samples are similar to those in the soils and sands. Among elements which could be regarded as being at trace concentrations the average S concentration in the soils is 0.9 g kg-1 whereas it is not detected in the sand samples. Zinc and Cu concentrations are both higher in the soils than the sands and are strongly correlated. A surprising presence of uranium at a concentration of 350 mg kg-1 was detected in the PIXE measurement on one of the dry lake samples. Gamma spectrometry confirmed the presence of U in this sample and also at a lower level in a sample from the lake shore, but in none of the other samples. Further, the gamma spectrometry showed that 238U decay products were present only at a level corresponding to about 3 mg kg-1 U for a system in radioactive equilibrium, a figure which is typical for U in the earth's crust. Disequilibria between 238U and its decay products occur naturally but such a high degree of separation at high concentration would be unique if confirmed. PIXE and PIGE measurements of these samples highlight the difficulty in correlating trace element measurements with occurrence of indicators of sea salt in air particulate samples.

  4. PIXE analysis of trace and other mineral elements in phytopharmaceutical drugs

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Harangus, Livia; Iordan, Andreea; Gugiu, M.

    2002-01-01

    Despite of ongoing progress in the biochemistry of phytopharmaceutical drugs, their mineral micro- and trace elements have not been studied in detail. These elements may have therapeutic or toxic activity which should be assessed by sensitive investigations. The latter can be done by multielemental analysis with nuclear and atomic methods. We previously found 28 elements in some Romanian plant drugs by nuclear activation analysis. The availability of this method is, however, limited by the access to a nuclear reactor. Particle-induced X-ray emission (PIXE) is an alternative method with high performances in biomedicine and requiring no sample preparation for drugs' studies. We applied PIXE in the qualitative analysis of three plant drugs - Liv52, Mentat, and Geriforte - used as invigorators, protectors and prophylactics in oxidative stress diseases. Measurements with 3 MeV protons at the 8.5 MV NIPNE-HH (Horia Hulubei National Institute for Physics and Nuclear Engineering) tandem accelerator, using a hyper-pure Ge detector and no additional absorber foil, evidenced unusually complex elemental compositions of drugs. Up to 31 elements with Z > 15 were found: P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Zr, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Hg, and As and/or Pb, from major to trace levels. The three drugs' qualitative composition were found to be rather similar. Relative concentrations were well evaluated with X-ray yields calculated for another kind of light element thick target. Drug's toxic elements - As and/or Pb, Hg, and possibly Ga - were all at trace levels, but their accumulation might be harmful. Some essential elements like K, Ca, Cr, Fe, Cu, Zn, Br, Rb, Sr can be biologically useful. X-ray yields improvement and other ways for PIXE quantitative analysis of the phytotherapeutic drugs are outlined. (authors)

  5. Charge protection characterisation and drift time resolution improvement for GridPix

    NARCIS (Netherlands)

    Koppert, W.J.C.; Fransen, M.; van Bakel, N.; van der Graaf, H.; Hartjes, F.; Timmermans, J.; Visser, J.; Kluit, R.; Gromov, V.; Zappon, F.; Blanco Carballo, V.M.; Schmitz, Jurriaan; Bilevych, Y.; Bilevych, Y.

    2011-01-01

    A GridPix detector is a gaseous detector capable of detecting single primary electrons from ionising particles. Such a detector consists of a pixel chip as active anode covered with a thin layer of silicon rich silicon nitride (SiRN) for protection against discharges. A layer of 8 JlIl1 SiRN, and

  6. Screening criteria for siting waste management facilities: Regional Management Plan

    International Nuclear Information System (INIS)

    1986-01-01

    The Midwest Interstate Low-Level Radioactive Waste Commission (Midwest Compact) seeks to define and place into operation a system for low-level waste management that will protect the public health and safety and the environment from the time the waste leaves its point of origin. Once the system is defined it will be necessary to find suitable sites for the components of that waste management system. The procedure for siting waste management facilities that have been chosen by the compact is one in which a host state is chosen for each facility. The host state is then given the freedom to select the site. Sites will be needed of low-level waste disposal facilities. Depending on the nature of the waste management system chosen by the host state, sites may also be needed for regional waste treatment facilities, such as compactors or incinerators. This report provides example criteria for use in selecting sites for low-level radioactive waste treatment and disposal facilities. 14 refs

  7. 14th International Conference on Particle Induced X-ray Emission ("PIXE 2015")

    Science.gov (United States)

    Przybyłowicz, Wojciech Józef; Pineda-Vargas, Carlos

    2015-11-01

    This special issue of Nuclear Instruments and Methods in Physics Research B contains the proceedings of the 14th International Conference on Particle Induced X-ray Emission ("PIXE 2015") that was held in Somerset West (South Africa) from 25th February to 3rd March 2015.

  8. Environmental control of Tinto and Odiel river basins by PIXE

    International Nuclear Information System (INIS)

    Respaldiza, M.A.; Gomez-Camacho, J.; Lopez-Tarrida, A.J.

    1993-01-01

    A study of the elemental concentrations of sediments of the rivers Tinto and Odiel, in Huelva, Spain, has been performed using PIXE. Thirteen samples have been collected, seven in the Tinto and six in the Odiel. Concentrations of 19 elements have been determined in each of them. The analysis of the data illustrates the environmental impact of the mining and fertilizer plants in the area. (orig.)

  9. Cadmium localization and quantification in the plant Arabidopsis thaliana using micro-PIXE

    Science.gov (United States)

    Ager, F. J.; Ynsa, M. D.; Domínguez-Solís, J. R.; Gotor, C.; Respaldiza, M. A.; Romero, L. C.

    2002-04-01

    Remediation of metal-contaminated soils and waters poses a challenging problem due to its implications in the environment and the human health. The use of metal-accumulating plants to remove toxic metals, including Cd, from soil and aqueous streams has been proposed as a possible solution to this problem. The process of using plants for environmental restoration is termed phytoremediation. Cd is a particularly favourable target metal for this technology because it is readily transported and accumulated in the shoots of several plant species. This paper investigates the sites of metal localization within Arabidopsis thaliana leaves, when plants are grown in a cadmium-rich environment, by making use of nuclear microscopy techniques. Micro-PIXE, RBS and SEM analyses were performed on the scanning proton microprobe at the CNA in Seville (Spain), showing that cadmium is sequestered within the trichomes on the leaf surface. Additionally, regular PIXE analyses were performed on samples prepared by an acid digestion method in order to assess the metal accumulation of such plants.

  10. INAA and PIXE for the determination of the contents of extractable sediment

    International Nuclear Information System (INIS)

    Freitas, M.C.; Hipolito, C.S.

    2007-01-01

    The three-stage BCR sequential step reference extraction procedure was applied to the reference material BCR CRM 601, especially developed for fractionation studies. Extracted fractions were analyzed for Cr, Ni, Zn, Cd, and Pb, by k 0 -standardized instrumental neutron activation (k 0 INAA) and proton induced X-ray emission (PIXE), and flame atomic absorption spectrometry (FAAS). Sample preparation procedures were developed for both k 0 INAA and PIXE techniques, related to the evaporation of the solutions in order to get solid samples for neutron and proton irradiation. Quality control was assessed by intercomparison of the analytical results obtained by the applied techniques, which included results for a few certified reference materials. In the extracted fractions, chromium concentration was not determined accurately by both nuclear techniques. Concerning Cd, Ni, Pb, and Zn, the results were in general in good agreement with the certified values and FAAS. Some incomplete separation of the residue might have occurred. (author)

  11. A feasibility study of PETiPIX: an ultra high resolution small animal PET scanner

    Science.gov (United States)

    Li, K.; Safavi-Naeini, M.; Franklin, D. R.; Petasecca, M.; Guatelli, S.; Rosenfeld, A. B.; Hutton, B. F.; Lerch, M. L. F.

    2013-12-01

    PETiPIX is an ultra high spatial resolution positron emission tomography (PET) scanner designed for imaging mice brains. Four Timepix pixellated silicon detector modules are placed in an edge-on configuration to form a scanner with a field of view (FoV) 15 mm in diameter. Each detector module consists of 256 × 256 pixels with dimensions of 55 × 55 × 300 μm3. Monte Carlo simulations using GEANT4 Application for Tomographic Emission (GATE) were performed to evaluate the feasibility of the PETiPIX design, including estimation of system sensitivity, angular dependence, spatial resolution (point source, hot and cold phantom studies) and evaluation of potential detector shield designs. Initial experimental work also established that scattered photons and recoil electrons could be detected using a single edge-on Timepix detector with a positron source. Simulation results estimate a spatial resolution of 0.26 mm full width at half maximum (FWHM) at the centre of FoV and 0.29 mm FWHM overall spatial resolution with sensitivity of 0.01%, and indicate that a 1.5 mm thick tungsten shield parallel to the detectors will absorb the majority of non-coplanar annihilation photons, significantly reducing the rates of randoms. Results from the simulated phantom studies demonstrate that PETiPIX is a promising design for studies demanding high resolution images of mice brains.

  12. Characterisation by PIXE-RBS of metallic contamination of tissues surrounding a metallic prosthesis on a knee

    Energy Technology Data Exchange (ETDEWEB)

    Guibert, G. [Laboratoire de Physique Corpusculaire de Clermont-Ferrand, IN2P3/CNRS UMR 6533, Universite Blaise Pascal, 63177 Aubiere Cedex (France)]. E-mail: geoffroy.guibert@he-arc.ch; Irigaray, J.L. [Laboratoire de Physique Corpusculaire de Clermont-Ferrand, IN2P3/CNRS UMR 6533, Universite Blaise Pascal, 63177 Aubiere Cedex (France); Moretto, Ph. [Centre d' Etudes Nucleaires de Bordeaux-Gradignan, IN2P3/CNRS UMR 5797, Le Haut Vigneau, BP 120, 33175 Gradignan Cedex (France); Sauvage, T. [Centre d' Etudes et de Recherches par Irradiation, CNRS Orleans France, 3A rue de la ferollerie, 45071 Orleans Cedex 2 (France); Kemeny, J.L. [CHU, Service d' Anatomie et de Cytologie Pathologiques, Universite d' Auvergne, 63100 Clermont-Ferrand (France); Cazenave, A. [Institut Calot, 62608 Berck sur Mer Cedex (France); Jallot, E. [Laboratoire de Physique Corpusculaire de Clermont-Ferrand, IN2P3/CNRS UMR 6533, Universite Blaise Pascal, 63177 Aubiere Cedex (France)

    2006-09-15

    Implants used as biomaterials have to fulfill conditions of functionality, compatibility and sometimes bioactivity. There are four main families of biomaterials: metals and metal alloys, polymers, bioceramics and natural materials. Because of corrosion and friction in the human body, implants generate debris. This debris may develop toxicity, inflammation and prosthetic unsealing by osseous dissolution. Nature, size, morphology and amount of debris are the parameters influencing the tissue responses. In this paper, we characterised metallic contamination produced by knee prosthesis, composed with TiAl{sub 6}V{sub 4} or Co-Cr-Mo alloys, into surrounding capsular tissue by depth migration, in vivo behaviour, content, size and nature of debris by PIXE (Particle Induced X-ray Emission) method associated with RBS (Rutherford Backscattering Spectroscopy). Debris distribution in the whole articulation is very heterogeneous. Debris migrates several thousand micrometers in tissues, with a characteristic decrease. Solid metallic particles of about micrometer size are found in the most polluted samples, in both alloys TiAl{sub 6}V{sub 4} and Cr-Co-Mo. In the mean volume analysed by PIXE, the concentration mass ratios [Ti]/[V] and [Co]/[Cr] confirm the chemical stability of TiAl{sub 6}V{sub 4} debris and show the chemical evolution of Cr-Co-Mo debris. Development of a protocol to prepare thin targets permits us to correlate PIXE and histological analysis in the same zone. The fibrous tissue (collagen fibres, fibroblasts) and macrophage cells are observed with optical microscope in polluted areas. This protocol could locate other pathologies in ppm contamination range, thanks to the great sensitivity of the PIXE method.

  13. 6 MV Folded Tandem Ion Accelerator facility at BARC

    International Nuclear Information System (INIS)

    Gupta, S.K.

    2010-01-01

    The 6 MV Folded Tandem Ion Accelerator (FOTIA) facility is operational round the clock and accelerated beams of both light and heavy ions are being used extensively by various divisions of BARC, Universities, lIT Bombay and other R and D labs across the country. The FOTIA is an upgraded version of the old 5.5 MV single stage Van-de-Graaff accelerator (1962-1992). Since its commissioning in the year 2000, the poor beam transmission through the 180 deg folding magnet was a matter of concern. A systematic study for beam transmission through the accelerator was carried out and progressive modifications in folding magnet chamber, foil stripper holder and improvement in average vacuum level through the accelerator have resulted in large improvement of beam transmission leading to up to 2.0 micro-amp analyzed proton beams on target. Now the utilization of the beams from the accelerator has increased many folds for basic and applied research in the fields of atomic and nuclear physics, material science and radiation biology etc. Few new beam lines after the indigenously developed 5-port switching magnet are added and the experimental setup for PIXE, PIGE, External PIXE, 4 neutron detector, Proton Induced Positron Annihilation Spectroscopy (PIPAS) setup and the general purpose scattering chamber etc have been commissioned in the beam hall. The same team has developed a Low Energy Accelerator Facility (LEAF) which delivers negative ions of light and heavy ions for application in implantation, irradiation damage studies in semiconductor devices and testing of new beam line components being developed for Low Energy High Intensity Proton Accelerator (LEHIPA) programme at BARC. The LEAF has been developed as stand alone facility and can deliver beam quickly with minimum intervention of the operator. Few more features are being planned to deliver uniform scanned beams on large targets. (author)

  14. PIXE analysis of Chinese ancient greenish white porcelain

    International Nuclear Information System (INIS)

    Cheng Lin; Ding Xunliang; Feng Songlin; Cheng Huangsheng; Zhang WenJiang; Fan Changsheng

    2006-01-01

    This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis

  15. Trace element fingerprinting of emeralds by PIXE/PIGE

    International Nuclear Information System (INIS)

    Ma Xinpei; MacArthur, J.D.; Roeder, P.L.; Mariano, A.N.

    1993-01-01

    Gemologists consider the mineral beryl, beryllium aluminium silicate, to be the gem, emerald, when it contains sufficient chromium, >0.1%, to colour it a strong green. Emeralds usually contain other trace elements. To investigate the feasibility of distinguishing an emerald's country of origin through its trace content, the trace elements in emeralds and a few beryls from sixteen locations have been determined with a single nondestructive measurement using PIXE and PIGE. From the database established with this limited number of samples, distinguishing trace element patterns were found. (orig.)

  16. PIXE depth profiling using variation of detection angle

    International Nuclear Information System (INIS)

    Miranda, J.; Rickards, J.; Trejo-Luna, R.

    2006-01-01

    A method to apply particle induced X-ray emission (PIXE) for depth profiling, based on the variation of the X-ray detection angle, is proposed. The procedure uses X-ray yields normalized to those emitted at a particular reference angle. Application of the method to implanted samples and thin metallic films gave excellent results regarding the range of implanted ions and film thickness, respectively. However, there is no complete information about the width of the distribution of the implanted ions, emphasizing the need to develop a full mathematical algorithm to obtain the general depth profile

  17. PIXE analysis of Chinese ancient greenish white porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Lin [Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China)]. E-mail: chenglinbnu@hotmail.com; Ding Xunliang [Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing 100875 (China); Feng Songlin [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Cheng Huangsheng [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Zhang WenJiang [Jiangxi Provincial Institute of Cultural Relics and Archaeology, Nanchang 330008 (China); Fan Changsheng [Jiangxi Provincial Institute of Cultural Relics and Archaeology, Nanchang 330008 (China)

    2006-03-15

    This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis.

  18. PIXE analysis of Chinese ancient greenish white porcelain

    Science.gov (United States)

    Cheng, Lin; Ding, Xun-liang; Feng, Song-lin; Cheng, Huang-sheng; Zhang, Wen-Jiang; Fan, Chang-Sheng

    2006-03-01

    This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis.

  19. Quantitative analysis of ancient Egyptian pigments by external PIXE

    International Nuclear Information System (INIS)

    Uda, M.; Tsunokami, T.; Murai, R.; Maeda, K.; Harigai, I.; Nakayama, Y.; Yoshimura, S.; Kikuchi, T.; Sakurai, K.; Sasa, Y.

    1993-01-01

    Pigments painted on Egyptian excavations in the 18th Dynasty were analyzed successfully by external PIXE with the aid of the X-ray diffraction. A white pigment was composed on Mg 3 Ca(CO 3 ) 4 ; red: αFe 2 O 3 , αFeO.OH and AsS; pink: Mixtures of white and red pigments; yellow: αFeO.OH and As 2 S 3 ; and blue: CaO.CuO.4SiO 2 . (orig.)

  20. Trace element mapping of pyrite from Archean gold deposits – A comparison between PIXE and EPMA

    Energy Technology Data Exchange (ETDEWEB)

    Agangi, A., E-mail: aagangi@uj.ac.za [University of Johannesburg, Department of Geology, Auckland Park 2006 (South Africa); Przybyłowicz, W., E-mail: przybylowicz@tlabs.ac.za [Materials Research Department, iThemba LABS, National Research Foundation, Somerset West 7129 (South Africa); AGH University of Science and Technology, Faculty of Physics & Applied Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow (Poland); Hofmann, A., E-mail: ahofmann@uj.ac.za [University of Johannesburg, Department of Geology, Auckland Park 2006 (South Africa)

    2015-04-01

    Chemical zoning of pyrites can record the evolution of mineralising fluids at widely varying P–T conditions ranging from diagenesis to medium-grade metamorphism. If preserved, zoning can reveal growth textures, brecciation and veining, resorption and recrystallisation events, thus shedding light on the processes that contributed to ore formation. Chemical zoning of sulfides is invisible in optical microscopy, but can be studied by chemical etching, high-contrast back-scattering electron images, and elemental imaging. In this study we compared micro-PIXE and WDS-EPMA elemental maps on the chemically zoned pyrites in mineralised vein-bearing samples from the Sheba and Fairview gold mines in the Barberton Greenstone Belt, South Africa. Elemental images show complex distribution of trace elements, suggesting multiple events of pyrite crystallisation and gold deposition. EPMA maps show fine-scale variations reflecting growth and recrystallisation textures marked, in particular, by variations of As, Ni, and Co. In PIXE maps, gold occurs both as finely-distributed and discrete inclusions, suggesting incorporation in the pyrite structure as solid solution, and deposition as electrum inclusions, respectively. Micro-PIXE and EPMA provide complementary information, forming together a powerful tool to obtain information on chemical zoning of pyrites in ore deposits.

  1. Multivariate statistical treatment of PIXE analysis of some traditional Chinese medicines

    International Nuclear Information System (INIS)

    Xiaofeng Zhang; Jianguo Ma; Junfa Qin; Lun Xiao

    1991-01-01

    Elements in two kinds of 30 traditional Chinese medicines were analyzed by PIXE method, and the data were treated by multivariate statistical methods. The results show that these two kinds of traditional Chinese medicines are almost separable according to their elemental contents. The results are congruous with the traditional Chinese medicine practice. (author) 7 refs.; 2 figs.; 2 tabs

  2. A microPIXE investigation of the interaction of cells of Schizosaccharomyces pombe with the culture medium

    Energy Technology Data Exchange (ETDEWEB)

    Rombouts, P.M.M. [Ion Beam Centre, Advanced Technology Institute, School of Electronics and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom); Gomez-Morilla, I. [Ion Beam Centre, Advanced Technology Institute, School of Electronics and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom); Grime, G.W. [Ion Beam Centre, Advanced Technology Institute, School of Electronics and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom); Webb, R.P. [Ion Beam Centre, Advanced Technology Institute, School of Electronics and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom); Cuenca, L. [Fluids and Systems Research Centre, School of Engineering, University of Surrey, Guildford GU2 7XH (United Kingdom); Rodriguez, R. [Fluids and Systems Research Centre, School of Engineering, University of Surrey, Guildford GU2 7XH (United Kingdom); Browton, M. [Ion Beam Centre, Advanced Technology Institute, School of Electronics and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom); Wardell, N. [School of Biomedical and Molecular Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom); Underwood, B. [Fluids and Systems Research Centre, School of Engineering, University of Surrey, Guildford GU2 7XH (United Kingdom); Kirkby, N.F. [Fluids and Systems Research Centre, School of Engineering, University of Surrey, Guildford GU2 7XH (United Kingdom); Kirkby, K.J. [Ion Beam Centre, Advanced Technology Institute, School of Electronics and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)]. E-mail: k.kirkby@surrey.ac.uk

    2007-07-15

    Schizosaccharomyces pombe (S. pombe) is a eucaryotic cell type similar to mammalian cells but much more simple. As it also executes its cell cycle rapidly it is very useful for investigating basic processes in cells. In this paper we report a feasibility study of the applicability of microPIXE to investigate the interaction between S. pombe cells and the surrounding culture medium. Cells were cultured in various growth medium prior to preparation for analysis. 1 {mu}l drops of medium and cells were spotted onto polypropylene foils held in contact with a polished copper block previously cooled in liquid nitrogen. The samples were dehydrated by freeze-drying. Micro PIXE analysis was carried out with the IBC microbeam facility using a beam of 2.5 MeV protons focused to 1-2 {mu}m diameter. Initially no elemental contrast was observed between the cells and the medium, but by modifying the dilution of the cell suspension, the cells could be distinguished from the surrounding medium through an increased concentration of P and reduced concentration of Cl. The distribution of Na in the medium around the cells showed evidence of the action of the Na pump. Sporulation appears to be induced in the cells by adding Cu to the growth medium and the uptake of Cu by the cells could be clearly observed. This study shows that it is possible to analyse the mass transport of elements in and out of cells In the future this will enable concentration gradients to be analysed and allow the rate of production or consumption of individual cells to be calculated. By observing these patterns for individual cells (not populations) at various known points in the cell cycle, fundamental data can be derived.

  3. A microPIXE investigation of the interaction of cells of Schizosaccharomyces pombe with the culture medium

    International Nuclear Information System (INIS)

    Rombouts, P.M.M.; Gomez-Morilla, I.; Grime, G.W.; Webb, R.P.; Cuenca, L.; Rodriguez, R.; Browton, M.; Wardell, N.; Underwood, B.; Kirkby, N.F.; Kirkby, K.J.

    2007-01-01

    Schizosaccharomyces pombe (S. pombe) is a eucaryotic cell type similar to mammalian cells but much more simple. As it also executes its cell cycle rapidly it is very useful for investigating basic processes in cells. In this paper we report a feasibility study of the applicability of microPIXE to investigate the interaction between S. pombe cells and the surrounding culture medium. Cells were cultured in various growth medium prior to preparation for analysis. 1 μl drops of medium and cells were spotted onto polypropylene foils held in contact with a polished copper block previously cooled in liquid nitrogen. The samples were dehydrated by freeze-drying. Micro PIXE analysis was carried out with the IBC microbeam facility using a beam of 2.5 MeV protons focused to 1-2 μm diameter. Initially no elemental contrast was observed between the cells and the medium, but by modifying the dilution of the cell suspension, the cells could be distinguished from the surrounding medium through an increased concentration of P and reduced concentration of Cl. The distribution of Na in the medium around the cells showed evidence of the action of the Na pump. Sporulation appears to be induced in the cells by adding Cu to the growth medium and the uptake of Cu by the cells could be clearly observed. This study shows that it is possible to analyse the mass transport of elements in and out of cells In the future this will enable concentration gradients to be analysed and allow the rate of production or consumption of individual cells to be calculated. By observing these patterns for individual cells (not populations) at various known points in the cell cycle, fundamental data can be derived

  4. Characterization of arsenic-contaminated aquifer sediments from eastern Croatia by ion microbeam, PIXE and ICP-OES techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ujević Bošnjak, M., E-mail: magdalena.ujevic@hzjz.hr [Croatian National Institute of Public Health, Rockefelerova 7, 10000 Zagreb (Croatia); Fazinić, S. [Institute Ruđer Bošković, Bijenička cesta, 10000 Zagreb (Croatia); Duić, Ž. [University of Zagreb, Faculty of Mining, Geology and Petroleum Engineering, Pierottijeva 6, Zagreb (Croatia)

    2013-10-01

    Highlights: •ICP-OES and PIXE used in the characterization of As-contaminated sediments. •Observed high correlations between the results obtained by those techniques. •Discrepancies observed for Mn, and for the highest As concentrations. •Microbeam analyses showed As association with sulphides and iron. -- Abstract: Groundwater arsenic contamination has been evidenced in eastern Croatia and hydrochemical results suggest that the occurrence of arsenic in the groundwater depends on the local geology, hydrogeology, and geochemical characteristics of the aquifer. In order to perform the sediment characterization and to investigate arsenic association with the other elements in the sediments, 10 samples from two boreholes (PVc-3 and Gundinci 1) in eastern Croatia were analyzed using two techniques: PIXE (without sample pre-treatment) and ICP-OES (after digestion), as well by ion microbeam analyses. The results of the PIXE and ICP-OES techniques showed quite good agreement; however, greater discrepancies were observed at the higher arsenic and manganese mass ratios. According to both techniques, higher As mass ratios were observed in the sediments from the PVc-3 core (up to 651 mg/kg and 491 mg/kg using PIXE and ICP-OES analyses respectively) than from the Gundinci 1 core (up to 60 mg/kg using both techniques). Although arsenic association with Fe is expected, no correlation was observed. The microbeam analyses demonstrated that arsenic is associated with sulphides and iron in the most As-contaminated sample from the PVc-3 core, while this relationship was not evident in the most As-contaminated sample from the Gundinci 1 borehole.

  5. Characterization of arsenic-contaminated aquifer sediments from eastern Croatia by ion microbeam, PIXE and ICP-OES techniques

    International Nuclear Information System (INIS)

    Ujević Bošnjak, M.; Fazinić, S.; Duić, Ž.

    2013-01-01

    Highlights: •ICP-OES and PIXE used in the characterization of As-contaminated sediments. •Observed high correlations between the results obtained by those techniques. •Discrepancies observed for Mn, and for the highest As concentrations. •Microbeam analyses showed As association with sulphides and iron. -- Abstract: Groundwater arsenic contamination has been evidenced in eastern Croatia and hydrochemical results suggest that the occurrence of arsenic in the groundwater depends on the local geology, hydrogeology, and geochemical characteristics of the aquifer. In order to perform the sediment characterization and to investigate arsenic association with the other elements in the sediments, 10 samples from two boreholes (PVc-3 and Gundinci 1) in eastern Croatia were analyzed using two techniques: PIXE (without sample pre-treatment) and ICP-OES (after digestion), as well by ion microbeam analyses. The results of the PIXE and ICP-OES techniques showed quite good agreement; however, greater discrepancies were observed at the higher arsenic and manganese mass ratios. According to both techniques, higher As mass ratios were observed in the sediments from the PVc-3 core (up to 651 mg/kg and 491 mg/kg using PIXE and ICP-OES analyses respectively) than from the Gundinci 1 core (up to 60 mg/kg using both techniques). Although arsenic association with Fe is expected, no correlation was observed. The microbeam analyses demonstrated that arsenic is associated with sulphides and iron in the most As-contaminated sample from the PVc-3 core, while this relationship was not evident in the most As-contaminated sample from the Gundinci 1 borehole

  6. Application of PIXE technique to studies on global warming/cooling effect of atmospheric aerosols

    International Nuclear Information System (INIS)

    Kasahara, M.; Hoeller, R.; Tohno, S.; Onishi, Y.; Ma, C.-J.

    2002-01-01

    During the last decade, the importance of global warming has been recognized worldwide. Atmospheric aerosols play an important role in the global warming/cooling effects. The physicochemical properties of aerosol particles are fundamental to understanding such effects. In this study, the PIXE technique was applied to measure the average chemical properties of aerosols. Micro-PIXE was also applied to investigate the mixing state of the individual aerosol particle. The chemical composition data were used to estimate the optical properties of aerosols. The average values of aerosol radiative forcing were -1.53 w/m 2 in Kyoto and +3.3 w/m 2 in Nagoya, indicating cooling and warming effects respectively. The difference of radiative forcing in the two cities may be caused by the large difference in chemical composition of aerosols

  7. The role of PIXE in the AIRUSE project “testing and development of air quality mitigation measures in Southern Europe”

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, F., E-mail: lucarelli@fi.infn.it [Department of Physics and Astronomy – University of Florence (Italy); National Institute of Nuclear Physics (INFN) – Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Chiari, M. [National Institute of Nuclear Physics (INFN) – Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Calzolai, G. [Department of Physics and Astronomy – University of Florence (Italy); Giannoni, M.; Nava, S. [National Institute of Nuclear Physics (INFN) – Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Udisti, R.; Severi, M. [Department of Chemistry – University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Italy); Querol, X.; Amato, F. [Institute of Environmental Assessment and Water Research (IDAEA-CSIC), 08034 Barcelona (Spain); Alves, C. [Centre for Environmental and Marine Studies (CESAM), Department of Environment, University of Aveiro, 3810-193 Aveiro (Portugal); Eleftheriadis, K. [Environmental Radioactivity Laboratory, N.C.S.R. Demokritos Univ., 15341 Ag. Paraskevi, Attiki (Greece)

    2015-11-15

    The European AIRUSE LIFE+ project aims at testing existing and future mitigation measures and developing new strategies for the improvement of air quality in Southern European countries. The project involves public and private institutions of Spain, UK, Portugal, Italy and Greece. PM10 and PM2.5 daily samplings have been scheduled for one year (from January 2013) in four urban sites, Barcelona (Spain), Porto (Portugal), Athens (Greece), and Florence (Italy). The daily data set gives an overall representative picture of the PM composition in these urban sites. The project includes also samplings with hourly resolution for limited periods. Hourly samples give an easier identification of the different aerosol sources due to the capability of tracking rapid changes as the ones occurring in many particulate emissions as well as in atmospheric transport and dilution processes. The role of PIXE technique within the project has been described in this paper. The comparison of data obtained by different techniques (e.g. PIXE, IC and ICP) assured a quality assurance control on the huge quantity of data obtained in the project. PIXE data together with those obtained by other analytical techniques have been used to reconstruct the average aerosol chemical composition and in Positive Matrix Factorization (PMF) analysis to determine the aerosol sources and their impact on PM10 and PM2.5 mass. In particular the high sensitivity of PIXE for all the crustal elements (including Si which is not easily detected by ICP) allows the direct determination of the Saharan dust contribution. Finally, the 1-h resolution data, which can be obtained only by PIXE, confirmed and reinforced the identification of the aerosol sources obtained by the daily concentrations.

  8. Pre-Hispanic ceramics analyzed using PIXE and radiographic techniques

    International Nuclear Information System (INIS)

    Lima, S.C.; Rizzutto, M.A.; Added, N.; Barbosa, M.D.L.; Trindade, G.F.; Fleming, M.I.D.A.

    2011-01-01

    Ceramics objects are the most common artifacts found during excavation of archaeological sites and often depicts cultural habits and manufacturing technologies of the culture. The determination of macroscopic and microscopic characteristics of the ceramic objects such as the ceramic porosity, addition of tempers in the clay, main chemical components and the trace elements present in the ceramic can reveal many aspects about the manufacturing processes used by the culture, its degree of development, the provenance of the raw materials and the exchange networks. Also the radiography can help to investigate the manufactured processes, the size of the tempers used and the conservation status of the artifacts. In this present work two non-destructive techniques, radiography and PIXE (Particle Induced X-ray Emission) were used to characterize one set of thirty-six pre-Hispanic ceramic pieces from the Chimu Culture conserved in the Museu de Arqueologia e Etnologia (MAE/USP). The PIXE analyses performed in the external beam setup at LAMFI (Laboratório de Análise de Materiais por Feixes Iônicos) allowed measure the principal chemical elements such as Al, Si, K, Ti, Fe and Ca, present in this group of pieces. X-ray imagings allowed identify the manufacture processes, the granularity of the tempers used, as well as the similarity and the differences between the pieces studied.

  9. PIXE and NRA environmental studies by means of lichen indicators

    International Nuclear Information System (INIS)

    Hrynkiewicz, A.Z.; Szymczyk, S.; Kajfosz, J.; Olech, M.

    1980-01-01

    The trace element accumulating and integrating properties of epiphytic lichens were used for the study of air pollutions in Southern Poland. For the investigation of fluorine pollution by an aluminium plant the 19 F(p, p'γ) 19 F nuclear reaction, whereas for Pb and Br traffic pollution and heavy elements industrial pollution the PIXE method was used. The applicability of the lichen indicator method in environmental studies is discussed. (orig.)

  10. PIXE analysis of Moroccan architectural glazed ceramics of 14th-18th centuries

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Azzou, A.; El Amraoui, M.; Haddad, M.; Bejjit, L.; Ait Lyazidi, S.

    2009-01-01

    The PIXE analysis of glazes and ceramic bodies of a set of architectural glazed ceramics (mostly the zellige mosaics), sampled from seven Moroccan monuments from the 14th to the 18th century AD, has been performed. We have identified high lead glazes, opacified with tin-oxide, laid over a calciferous body to produce hard tiles easy to chisel as required by the zellige technique. The analysis has revealed significant differences between the monuments examined: in particular in the formulation of the base glass and in the use of stains to produce coloured glazes. We observed the peculiarity of materials used in Marrakech and we could distinguish, both in terms of glazes and ceramic bodies, the two almost contemporary Madersas dedicated to the sultan Bou Inan, one in Meknes the other in Fez. The PIXE measurements integrate a broad range of spectrometric investigations performed in the past few years. (author)

  11. PIXE investigation of in-vitro release of chloramphenicol across polyvinyl alcohol/ acrylamide hydrogel

    International Nuclear Information System (INIS)

    Rihawi, M.; Al-Zeer, A.; Allaf, A.

    2012-01-01

    Hydrogels based on polyvinyl alcohol (PVA) and different amounts of acrylamide monomer (AAm) were prepared by thermal crosslinking process in solid state. The PVA/AAm hydrogels were investigated for drug delivery system applications. Chloramphenicol was adopted as a model drug to study its release behaviour across the prepared hydrogels. Particle induced X-ray emission (PIXE) analytical technique was utilized to study the drug release behaviour across the hydrogels. A comparison study between PIXE and UV measurements was performed. FTIR measurements were carried out to perform the molecular characterization. The releasing behaviour of the drug across the hydrogels demonstrates a decrease and a subsequent increase in the drug release rate, as the AAm amount increases. The FTIR characterization of the prepared hydrogels has shown a competitive behaviour between the crosslinking of PVA with AAm monomer or oligomerized AAm, depending on the amount of AAm added to prepare the PVA/AAm hydrogels. (author)

  12. Plans for dealing with loss of access to the Midwest Compact Regional Disposal Facility: Regional Management Plan

    International Nuclear Information System (INIS)

    1986-01-01

    This report describes events that could lead to the premature closure of a disposal facility and the prospects that the closed facility could eventually be reopened. Possible courses of action leading to disposal outside the Midwest region while the Midwest Compact works to reestablish a regional disposal capability are also discussed. A likely division of responsibilities between the Compact Commission and the individual member states, with emphasis on managing low-level waste after a loss of access when disposal outside the Midwest is not possible is presented. Key elements in an agreement between compacts to accept each other's waste when one compact has experienced an unexpected interruption of its disposal operation are described

  13. Application of PIXE to the study of Renaissance style enamelled gold jewelry

    Science.gov (United States)

    Weldon, M.; Carlson, J.; Reedy, S.; Swann, C. P.

    1996-04-01

    This study examines and compares three pieces of Renaissance style gold and enamelled jewelry owned by the Walters Art Gallery, Baltimore, MD, USA. These are a 16th century Hat Badge of Adam and Eve, a 19th century Fortitude Pendant and a Diana Pendant presumed to be of the 16th century (The Walters Art Gallery, Jewelry, Ancient to Modern (Viking, New York, 1979)), Ref. [1]. PIXE spectroscopy was applied to examine the elemental composition of the gold and of the enamels. Compositional differences, including the use of post-Renaissance colorants, were found between the enamels in separate regions of each of the three pieces. The modern colorant, chromium, was, in fact, found in all of the pieces and uranium was found in only the Diana Pendant. There are some differences in the gold purity of the three objects; there are significant differences in the solders used even within one object, the Fortitude Pendant.

  14. Multielemental analysis of ferromanganese nodules from Central Indian Ocean Basin by PIXE

    International Nuclear Information System (INIS)

    Dutta, R. K.; Vijayan, V.; Ghosh, S.; Chakravortty, V.

    1997-01-01

    Ferromanganese nodules found on the Ocean bed are complex heterogeneous mixtures of several components. Two nodules from Central Indian Ocean Basin (CIOB) were analysed by proton induced X-ray emission (PIXE) technique using 3UD Tandem pelletron. The precision and the accuracy of this technique for chemical analyses has been confirmed by analysing USGS Geological Standards. Thick sample targets were bombarded by 3 MeV protons for the multielemental analysis. GUPIX-96 software was used for spectral data analysis. Quantitative estimate of K, Ca, Tl, V, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Rb, Sr, Y, Zr, Mo, Ba, Ce, Tl and Pb has been ascertained. The occurrence of Ga, Ge, Rb and Zr in nodules from this region is reported for the first time. The role of manganese and iron oxide phases in determining the uptake of various trace elements from ocean water and bottom sediment pore water has been discussed. (author)

  15. Micro-PIXE analysis of fish otoliths. Methodology and evaluation of first results for stock discrimination

    International Nuclear Information System (INIS)

    Sie, S.H.; Thresher, R.E.

    1992-01-01

    Micro-PIXE has been used to measure the trace element distribution in otoliths from several species of ocean fish, in order to investigate its possible use in stock discrimination. Trace elements detected include Sr, Fe, Mn, Ni, Zn, Cu, Se, Cd, Br, Hg and Pb. Trace elements Na, K, Cl, S and Cl were detected with the electron microprobe. The high sensitivity of PIXE demands a meticulous sample preparation procedure to avoid contamination problems. Practical problems associated with the application of the technique were investigated in detail. Preliminary results indicate that most trace elements except Sr, are present at close to the limits of detection at few ppm, but biologically significant data can be obtained for stock discrimination applications. (author)

  16. Quantitative elemental localisation in leaves and stems of nickel hyperaccumulating shrub Hybanthusfloribundus subsp. floribundus using micro-PIXE spectroscopy

    International Nuclear Information System (INIS)

    Kachenko, Anthony G; Singh, Balwant; Bhatia, Naveen P; Siegele, Rainer

    2008-01-01

    Hybanthusfloribundus (Lindl.) F.Muell. subsp. floribundus is a native Australian nickel (Ni) hyperaccumulating shrub and a promising species for rehabilitation and phytoremediation of Ni tailings. Spatial localisation and quantification of Ni in leaf and stem tissues of H.floribundus subsp. floribundus was studied using micro-proton-induced X-ray emission (micro-PIXE) spectroscopy. Young plants, grown in a potting mix under controlled glasshouse conditions were exposed to Ni concentrations of 0 and 26 mM kg -1 for 20 weeks. Leaf and stem samples were hand-sectioned and freeze-dried prior to micro-PIXE analysis. Elemental distribution maps of leaves revealed Ni concentration of 7800 mg kg -1 dry weight (DW) in whole leaf sections, which was identical to the bulk tissue analysis. Elemental maps showed that Ni was preferentially localised in the adaxial epidermis (10,000 mg kg -1 DW) and reached a maximum of up to 10,000 mg kg -1 DW in the leaf margin. Freeze-dried stem sections from the same plants contained lower Ni than leaf tissues (1800 mg kg -1 versus 7800 mg kg -1 DW, respectively), however did not resolve a clear pattern of compartmentalisation across different anatomical regions. Our results suggest localisation in epidermal cells is an important physiological mechanism involved in Ni accumulation and tolerance in leaves of H.floribundus subsp. floribundus

  17. An external proton beam at VERA to study objects of art by proton induced x-ray emission (PIXE)

    International Nuclear Information System (INIS)

    Kroepfl, P.; Forstner, O.; Kutschera, W.; Priller, A.; Steier, P.; Wallner, A.; Wuenschek, B.; Golser, R.

    2006-01-01

    Full text: PIXE is a very sensitive analytical method to determine the chemical composition of art objects, e.g. drawings, handwritings etc. A particular advantage is the possibility to analyze objects non-destructively under atmospheric pressure. Such an external beam PIXE facility is currently implemented at the Vienna Environmental Research Accelerator (VERA). The set-up allows to extract a 3 MeV proton beam of approximately 100 μm in diameter and currents in the range of a few nA's through an ultra-thin (0.1 μm) Silicon Nitride window. The characteristic x-rays emitted from the specimen are recorded with a Si(Li) and a Silicon Drift detector simultaneously to cover the widest possible Z-range of the detected elements. We have just completed an extensive period of studying beam effects on ancient paper to exclude possible damage to art objects, in particular drawings of the Renaissance that are among the most precious and rarest treasuries of graphical collections. They were created with different materials such as inks, chalks and metal points. A large collection of these fine arts objects is situated at the Albertina in Vienna. Together with scientists from the Centre de Recherche et de Restauration des Musees de France (C2RMF) in Paris, I. Reiche, A. Duval, H. Guicharnaud, from the CEREGE UMR CNRS 6635 in Aix-en-Provence, S. Merchel, from the Albertina in Vienna, E. Thobois, H. Singer, and from the Akademie der bildenden Kuenste in Vienna, M. Schreiner, we want then to analyze a few selected silverpoint drawings by Albrecht Duerer (1471-1528). (author)

  18. Mineral elements in dental composites by atomic and nuclear analytical methods. II. Improved analysis by PIXE

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Ciortea, C.; Fluerasu, D.; Enescu, S.E.; Preoteasa, Elena

    2000-01-01

    In the corrosive environment of the mouth, a diversity of interactions take place at the solid-solid and solid-liquid interfaces of a tooth's filling. Moreover, the mineral elements of the restorative material may induce a complex response of the organism. The approach of these problems requires sensitive surface elemental analysis of the composite and of the dental enamel and dentine. Particle-induced X-ray emission (PIXE) is such a method and has been applied in investigations of hard dental tissues; however, it was not used so far in the study of dental composites. We continue our study by evaluating the potential of PIXE for analysis of these materials. Three types of composites with two color shades each have been studied. The measurements were performed with 3 MeV protons, using a hyperpure Ge detector in a spectroscopic chain connected to a computer. The spectra were processed with the dedicated program Leone. PIXE without additional Al absorbent foil allowed the detection of Z > 14 elements in composites. In two glass- and ceramics-based materials we found: Ca, Zr, Ba, Yb and traces of Sr and In in Tetric Ceram (Vivadent); and Ca, Zr, Ba, Hf, possibly Mn, and traces of Ni, Ho, Ti, Fe, Cr in Valux Plus (3M Dental), after elimination of the escape peaks. In quartz-based Evicrol (Spofa), Si, Ca, Ti, Fe and traces of K, Cr, Ni, Cu, Zn were seen. Materials with different color shades showed variations of Ti, Cr, Fe, Ni and Cu in Evicrol, as contrasted to Tetric Ceram and Valux Plus whose spectra were color-invariant. By its sensitivity and low background, PIXE enables the detection of many trace elements in dental composites; it could serve also in new materials' development and forensic expertise. (authors)

  19. Prototype Web-based continuing medical education using FlashPix images.

    Science.gov (United States)

    Landman, A; Yagi, Y; Gilbertson, J; Dawson, R; Marchevsky, A; Becich, M J

    2000-01-01

    Continuing Medical Education (CME) is a requirement among practicing physicians to promote continuous enhancement of clinical knowledge to reflect new developments in medical care. Previous research has harnessed the Web to disseminate complete pathology CME case studies including history, images, diagnoses, and discussions to the medical community. Users submit real-time diagnoses and receive instantaneous feedback, eliminating the need for hard copies of case material and case evaluation forms. This project extends the Web-based CME paradigm with the incorporation of multi-resolution FlashPix images and an intuitive, interactive user interface. The FlashPix file format combines a high-resolution version of an image with a hierarchy of several lower resolution copies, providing real-time magnification via a single image file. The Web interface was designed specifically to simulate microscopic analysis, using the latest Javascript, Java and Common Gateway Interface tools. As the project progresses to the evaluation stage, it is hoped that this active learning format will provide a practical and efficacious environment for continuing medical education with additional application potential in classroom demonstrations, proficiency testing, and telepathology. Using Microsoft Internet Explorer 4.0 and above, the working prototype Web-based CME environment is accessible at http://telepathology.upmc.edu/WebInterface/NewInterface/welcome.html.

  20. PIXE analysis of proteins from a photochemical center

    Science.gov (United States)

    Solís, C.; Oliver, A.; Andrade, E.

    1998-03-01

    In oxygen evolving photosynthetic organisms, light is absorbed and its energy used for the conversion of chemical products in two photosystems: PSI and PSII. Each photosystem is composed of a protein core which binds a pigment antenna and a Reaction Center (RC). RC of PSI is considered an "Iron-Sulfur" type. There are six components that participate in the charge separation after light absorption occurs in PSI: the center chlorophyll P700, two acceptors A 0 and A 1 and three FeS centers F X, F A and F B. However, the exact number of polypeptides, their exact molecular weight, their relative abundances and the active components associated to those polypeptides remain still to be completely characterized. In particular the FeS centers have been difficult to detect in a direct way in a gel band, because the amount of centers involved is under the detection limits of the conventional techniques. This study has been under-taken to explore the capability of particle induced X-ray emission (PIXE) to detect in a qualitative way the presence of Fe in some of the protein bands obtained by Sodium Dodecyl Sulfate Polyacrylamide Gel Electrophoresis (SDS-PAGE) from the PSI complex. The complex was isolated from membranes of thermophilic cyanobacteria: Synechochoccus sp. The polyacrylamide gel electrophoresis of the complex shows eight subunits of 66, 60-65, 14, 13, 9, 8 and 7 KDa. In-air PIXE was performed at 2 MeV and proved to be an adequate tool for direct identification of the iron present in the gel bands.

  1. A new ion beam facility based on a 3 MV Tandetron™ at IFIN-HH, Romania

    Science.gov (United States)

    Burducea, I.; Straticiuc, M.; Ghiță, D. G.; Moșu, D. V.; Călinescu, C. I.; Podaru, N. C.; Mous, D. J. W.; Ursu, I.; Zamfir, N. V.

    2015-09-01

    A 3 MV Tandetron™ accelerator system has been installed and commissioned at the "Horia Hulubei" National Institute for Physics and Nuclear Engineering - IFIN-HH, Măgurele, Romania. The main purpose of this machine is to strengthen applied nuclear physics research ongoing in our institute for more than four decades. The accelerator system was developed by High Voltage Engineering Europa B.V. (HVE) and comprises three high energy beam lines. The first beam line is dedicated to ion beam analysis (IBA) techniques: Rutherford Backscattering Spectrometry - RBS, Nuclear Reaction Analysis - NRA, Particle Induced X-ray and γ-ray Emission - PIXE and PIGE and micro-beam experiments - μ-PIXE. The second beam line is dedicated to high energy ion implantation experiments and the third beam line was designed mainly for nuclear cross-sections measurements used in nuclear astrophysics. A unique feature, the first time in operation at an accelerator facility is the Na charge exchange canal (CEC), which is used to obtain high intensity beams of He- of at least 3 μA. The results of the acceptance tests demonstrate the huge potential of this new facility in various fields, from IBA to radiation hardness studies and from medical or environmental applications to astrophysics. The main features of the accelerator are presented in this paper.

  2. Heavy metal distribution in Suillus luteus mycorrhizas - as revealed by micro-PIXE analysis

    Science.gov (United States)

    Turnau, K.; Przybyłowicz, W. J.; Mesjasz-Przybyłowicz, J.

    2001-07-01

    Suillus luteus/Pinus sylvestris mycorrhizas, collected from zinc wastes in Southern Poland, were selected as potential biofilters on the basis of earlier studies carried out with energy dispersive spectrometry (EDS) microanalytical system coupled to scanning electron microscope (SEM) and transmission electron microscope (TEM). Using the National Accelerator Centre (NAC) nuclear microprobe, elemental concentrations in the ectomycorrhiza parts were for the first time estimated quantitatively. Micro-proton-induced X-ray emission (PIXE) true elemental maps from freeze-dried and chemically fixed mycorrhizas revealed strong accumulation of Ca, Fe, Zn and Pb within the fungal mantle and in the rhizomorph. Vascular tissue was enriched with P, S and K, while high concentrations of Si and Cl were present in the endodermis. Cu was the only element showing elevated concentrations in the cortex region. Elemental losses and redistributions were found in mycorrhizas prepared by chemical fixation. Some problems related to elemental imaging are discussed.

  3. Heavy metal distribution in Suillus luteus mycorrhizas - as revealed by micro-PIXE analysis

    International Nuclear Information System (INIS)

    Turnau, K.; Przybylowicz, W.J.; Mesjasz-Przybylowicz, J.

    2001-01-01

    Suillus luteus/Pinus sylvestris mycorrhizas, collected from zinc wastes in Southern Poland, were selected as potential biofilters on the basis of earlier studies carried out with energy dispersive spectrometry (EDS) microanalytical system coupled to scanning electron microscope (SEM) and transmission electron microscope (TEM). Using the National Accelerator Centre (NAC) nuclear microprobe, elemental concentrations in the ectomycorrhiza parts were for the first time estimated quantitatively. Micro-proton-induced X-ray emission (PIXE) true elemental maps from freeze-dried and chemically fixed mycorrhizas revealed strong accumulation of Ca, Fe, Zn and Pb within the fungal mantle and in the rhizomorph. Vascular tissue was enriched with P, S and K, while high concentrations of Si and Cl were present in the endodermis. Cu was the only element showing elevated concentrations in the cortex region. Elemental losses and redistributions were found in mycorrhizas prepared by chemical fixation. Some problems related to elemental imaging are discussed

  4. SR XRF and micro-PIXE studies on ancient metallurgy of thirteen Dacian gold bracelets

    Science.gov (United States)

    Constantinescu, Bogdan; Vasilescu, Angela; Radtke, Martin; Reinholz, Uwe; Pacheco, Claire; Pichon, Laurent; Oberländer-Târnoveanu, Ernest

    2012-11-01

    A thorough microscopic investigation by SR XRF and micro-PIXE brings insight into the probable techniques used in the manufacture of thirteen Dacian gold bracelets, one of the most spectacular archaeological finds ever on the territory of Romania.

  5. PIXE analysis: an option for the study of atmospheric pollutants

    International Nuclear Information System (INIS)

    Aldape, U.F.

    1989-01-01

    Several techniques have been utilized in studying atmospheric contamination samples. However, each lack some characteristics required for these studies. Spectroscopy of X-rays particularly where excitation models are produced using charged particles (Particle Induced X-ray Emission, PIXE), for its high sensitivity, is the one that best fitting itself to the scheme of analysis required. In this paper we report some qualitative results of the atmospheric aerosol samples collected in Mexico City. (Author)

  6. External beam pixe programs at the University of California, Davis

    International Nuclear Information System (INIS)

    Eldred, R.A.

    1983-01-01

    A PIXE system in which large or delicate samples are excited by a low-current external proton beam is described. This system has been used to analyze historical printed books and manuscripts, as well as a large variety of archeological artifacts. The steps used to protect the sample from unnecessary beam current are examined. A recent thorough study of the first volume of the Gutenberg 42-line Bible is described in some detail

  7. PIXE-PIGE analysis of late roman glass fragments

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Tubio, B. [Departamento de Fisica Aplicada III, Escuela de Ingenieros, Universidad de Sevilla, Camino de los Descubrimientos s/n, 41092 Sevilla (Spain)]. E-mail: tubio@us.es; Ontalba Salamanca, M.A. [Departamento de Fisica, Escuela Politecnica, Universidad de Extremadura, Avda. de la Universidad s/n, 10071 Caceres (Spain); Ortega-Feliu, I. [Centro Nacional de Aceleradores, Universidad de Sevilla, Avda. Thomas A. Edison s/n, 41092 Sevilla (Spain); Respaldiza, M.A. [Centro Nacional de Aceleradores, Universidad de Sevilla, Avda. Thomas A. Edison s/n, 41092 Sevilla (Spain); Amores Carredano, F. [Departamento de Prehistoria y Arqueologia, Universidad de Sevilla, C/Dona Maria de Padilla s/n, 41010 Sevilla (Spain); Gonzalez-Acuna, D. [Departamento de Geografia, Historia y Filosofia, Universidad Pablo de Olavide, Ctra. de Utrera Km 1, 41013 Sevilla (Spain)

    2006-08-15

    A set of Roman glass fragments, excavated at Sevilla and dated in the 5th century A.D., has been analysed by PIXE and PIGE techniques using the external beam set-up of the 3 MV tandem Pelletron accelerator of the CNA at the University of Sevilla. Using a simple quantification method, based on the indirect charge calculation on the sample by monitoring the X-ray induced by the proton beam on the exit window, the composition of the glasses has been determined. From the obtained results, the use of soda as flux has been inferred and colouring manufacture procedures have been identified.

  8. PIGE-PIXE analysis of medicinal plants and vegetables of pharmacological importance

    International Nuclear Information System (INIS)

    Olabanji, S.O.; Makanju, O.V.

    1995-08-01

    PIGE and PIXE techniques were employed to the study of elemental constituents of some traditional medicinal plants generally used in curing many diseases and ailments in South-Western Nigeria. Analysis were also carried out on commonly edible vegetables of medicinal and pharmacological importance. PIGE measurements were carried out using 3.5 MeV collimated protons from the 7 MV CN Van-de-Graaff accelerator of INFN, LNL, Legnaro (Padova), Italy, while the PIXE measurements were carried out using 1.8 MeV from the 2.5 MV AN 2000 Van-de-Graaff accelerator of the same laboratory. The results show that many of the medicinal plants contain elements of cardinal importance in man's metabolism. The results from the vegetables also show that presence of vital elements that are needed for growth and developments. In addition, some of the toxic elements which include arsenic, cadmium, mercury, etc. were not detected. However, some of the recipes contain trace amounts of lead at very low concentrations. This calls for proper control of dose rates in some samples to prevent the attendant negative cumulative effects. (author). 17 refs, 1 fig., 5 tabs

  9. Analysis of ancient Indian silver punch-marked coins by external PIXE

    International Nuclear Information System (INIS)

    Rautray, Tapash R.; Nayak, Suman S.; Tripathy, Bipin B.; Das, Saubhagyalaxmi; Das, Manas R.; Das, Satya R.; Chattopadhyay, Pranab K.

    2011-01-01

    Seven silver punch-marked coins were analysed using external particle induced X-ray emission technique. The main group of elements like Ag, Cu, Au, Pb and Fe were estimated along with a number of trace/minor elements such as K, Ca, Ti, V, Cr, Mn, Co, Ni and Rb in the analysed silver coins. Gold was found in all the coins and varied between 0.7% and 6.2% indicating the better economic condition of that civilisation. - Highlights: → The silver punch-marked coins, in the current study, were in use in India between 6th century BC to 6th century AD and have been analysed by in-air PIXE. → These sets of coins have immense archaeological importance because of their very rare availability. → These coins are distinguished from other coins because of the presence of gold as major element. → While the British period coins were fabricated using modern technologies, the punch-marked coins were shaped manually with developed metal technology. → The analysis of punch-marked coins using external PIXE beam has been done for the first time, which is unique of its kind.

  10. SR XRF and micro-PIXE studies on ancient metallurgy of thirteen Dacian gold bracelets

    International Nuclear Information System (INIS)

    Constantinescu, Bogdan; Vasilescu, Angela; Radtke, Martin; Reinholz, Uwe; Pacheco, Claire; Pichon, Laurent; Oberlaender-Tarnoveanu, Ernest

    2012-01-01

    A thorough microscopic investigation by SR XRF and micro-PIXE brings insight into the probable techniques used in the manufacture of thirteen Dacian gold bracelets, one of the most spectacular archaeological finds ever on the territory of Romania. (orig.)

  11. Status of data and data needs for XRF and PIXE based element analysis

    International Nuclear Information System (INIS)

    Kapoor, S.S.; Choudhary, R.K.

    1986-01-01

    The status of data and data needs for X-ray fluorescence (XRF) and particle induced X-ray (PIXE) are examined to determine the areas where additional and improved data are required to improve the accuracy, precision and sensitivity of quantitative element analysis by the above techniques. (author)

  12. Elemental imaging of organic matter and associated metals in ore deposits using micro PIXE and micro-EBS

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, S., E-mail: fuchs@geomin.eu [Department of Earth and Planetary Science, McGill University, 3450 University Street, Montreal H3A 0E8 (Canada); Przybylowicz, W.J., E-mail: przybylowicz@tlabs.ac.za [Materials Research Department, iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow (Poland); Williams-Jones, A.E., E-mail: anthony.williams-jones@mcgill.ca [Department of Earth and Planetary Science, McGill University, 3450 University Street, Montreal H3A 0E8 (Canada)

    2014-01-01

    Micro-PIXE and micro-EBS analyses were carried out on samples from the Au–U-bearing Carbon Leader Reef of the Witwatersrand in South Africa to investigate the role of organic matter in the formation of this deposit. Micro-PIXE and Micro-EBS shows a very complex metal distribution within the bitumen nodules and their interstitial spaces. The style of the gold distribution and its association with epigenetic minerals (REE phosphates, phyllosilicates) indicates that all observed gold migrated in aqueous solution and precipitated by reduction on the surfaces of the bitumen nodules. Uraninite occurrences are confined to the bitumen nodules, which supports the argument of a uraninite paleo-placer; however the pervasive distribution of uranium also supports the argument that uraninite is derived from organo-metallic complexes. This study shows that micro-PIXE is a powerful tool to characterize metals associated with hydrocarbons. However, the organic matrix, the complexity of the obtained spectra and the small size of the minerals have significant influence on the reliability of the quantitative data. Due to highly variable amounts of heavy metals (U, Au, Pb) the obtained micro-EBS results are of questionable quality.

  13. Long term fine aerosol analysis by XRF and PIXE techniques in the city of Rijeka, Croatia

    International Nuclear Information System (INIS)

    Ivošević, Tatjana; Orlić, Ivica; Radović, Iva Bogdanović

    2015-01-01

    Highlights: • For the first time in Croatia, long term of fine aerosol pollution is reported. - Abstract: The results of a long term, multi elemental XRF and PIXE analysis of fine aerosol pollution in the city of Rijeka, Croatia, are reported for the first time. The samples were collected during a seven months period (6th Aug 2013–28th Feb 2014) on thin stretched Teflon filters and analyzed by energy dispersive X-ray fluorescence (EDXRF) at the Laboratory for Elemental Micro-Analysis (LEMA), University of Rijeka and by Particle Induced X-ray Emission (PIXE) using 1.6 MeV protons at the Laboratory for Ion Beam Interactions (LIBI), Ruđer Bošković Institute, Zagreb. The newly developed micro-XRF system at LEMA provided results for 19 elements in the range from Si to Pb. The PIXE at the LIBI provided information for the same elements as well for the light elements such as Na, Mg and Al. Black carbon was determined with the Laser Integrated Plate Method (LIPM). The results were statistically evaluated by means of the positive matrix factorization (PMF). The seven major pollution sources were identified together with their relative contributions, these are: secondary sulfates, road traffic, smoke, road dust, sea spray, ship emissions and soil dust.

  14. Long term fine aerosol analysis by XRF and PIXE techniques in the city of Rijeka, Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Ivošević, Tatjana [Faculty of Engineering, University of Rijeka, Vukovarska 58, HR-51000 Rijeka (Croatia); Orlić, Ivica [Department of Physics, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka (Croatia); Radović, Iva Bogdanović [Laboratory for Ion Beam Interaction, Ruđer Bošković Institute, Bijenička 54, HR-10000 Zagreb (Croatia)

    2015-11-15

    Highlights: • For the first time in Croatia, long term of fine aerosol pollution is reported. - Abstract: The results of a long term, multi elemental XRF and PIXE analysis of fine aerosol pollution in the city of Rijeka, Croatia, are reported for the first time. The samples were collected during a seven months period (6th Aug 2013–28th Feb 2014) on thin stretched Teflon filters and analyzed by energy dispersive X-ray fluorescence (EDXRF) at the Laboratory for Elemental Micro-Analysis (LEMA), University of Rijeka and by Particle Induced X-ray Emission (PIXE) using 1.6 MeV protons at the Laboratory for Ion Beam Interactions (LIBI), Ruđer Bošković Institute, Zagreb. The newly developed micro-XRF system at LEMA provided results for 19 elements in the range from Si to Pb. The PIXE at the LIBI provided information for the same elements as well for the light elements such as Na, Mg and Al. Black carbon was determined with the Laser Integrated Plate Method (LIPM). The results were statistically evaluated by means of the positive matrix factorization (PMF). The seven major pollution sources were identified together with their relative contributions, these are: secondary sulfates, road traffic, smoke, road dust, sea spray, ship emissions and soil dust.

  15. Results from the nuclear microprobe PIXE analysis of selected rare earth fluor compounds

    International Nuclear Information System (INIS)

    Hollerman, William A.; Gates, Earl; Boudreaux, Philip; Glass, Gary A.

    2002-01-01

    Most previous research measures fluorescence properties over the macroscopic regime. Properties of individual microscopic grains could be significantly different than those measured over the macroscopic scale. Until recently, it was difficult to measure properties of individual fluor grains. Existing characterization techniques like scanning electron microscopy are not practical, since the resulting fluorescence masks the electron surface profile. Starting in September 2000, a research program was initiated at the Acadiana Research Laboratory to determine microscopic fluorescence properties for selected inorganic rare earth compounds. The initial phase of this program utilized microscopic proton induced X-ray emission (μPIXE) to characterize the elemental composition of individual fluor grains. Results show that both individual grains and small clusters of grains could be seen using μPIXE. Maps of this type can be used to estimate grain dimensions for the selected rare earth fluor. This technique is a new and innovative method to characterize a fluor material

  16. Speciation of uranium in minerals by Sem, Tem, μ-PIXE, XPS and XAFS

    International Nuclear Information System (INIS)

    Toshihiko Ohnuki; Hiroshi Isobe; Tomihiro Kamiya; Takuro Sakai; Takashi Murakami

    2001-01-01

    Many kinds of electromagnetic waves and particle beams are used as analytical probes for the investigation of uranium-mineralogy and speciation. The representatives of the probes are SEM, TEM, μ-PIRE, XPS and XAFS. Each of these analytical probes has its own advantages and disadvantages. We have performed studies to compare the advantages and disadvantages on the basis of the analysis of the distribution and speciation of U containing rock samples collected at the Koongarra uranium deposit, Australia. The spatial resolutions of the probes are in the order of TEM>SEM, μ-PIXE>XFAS, XPS. The lower detection limits of the probes are in the order of μ-PIXE< TEM, SEM< XFAS, XPS. Oxidation state of U was determined by XFAS and XPS. These results indicate that combination of the above probes can give us sufficient data on U speciation not only in natural rock samples but in solid samples obtained in the laboratory. (authors)

  17. Authenticity determination of Ag-Cu Lebanese coins using combined PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Roumie, M; Nsouli, B; Assafiri, Y

    2012-01-01

    A set of silver-copper coins were investigated for their stochiometry in order to check any possible counterfeit. The studied coins are 50 Lebanese Piastres and are relatively recent, minted in 1952. They are supposed to have nominal concentration of 60 wt.% Ag and 40 wt.% Cu. In this work, it is shown the utility and capability of combining PIXE (particle induced X-ray emission) and RBS (Rutherford backscattering spectrometry) techniques to determine the elemental content and check the presence, if any, of surface layer. For this aim, 3 MeV proton beam and Al funny filter, used as x-ray absorber, were used to determine the elemental composition, based on the emission and detection of the characteristic x-rays of the corresponding elements. The first PIXE results of the supposed bulky coins showed an excess of silver composition vs. copper. In addition, the experimental protocol was checked by analyzing some other coins of known composition, such as 1-euro and 2-euro coins.

  18. Can micro-PIXE measurements help to determine ore genesis ?

    International Nuclear Information System (INIS)

    Ahmed, M.; Al-Ohali, M.A.

    2002-01-01

    This study is an attempt to demonstrate how the nuclear micro-PIXE technique can be utilized to investigate ore genesis of geological deposits. Elemental concentrations and distribution profiles in single mineral grains and matrices in a present-day ore deposit on land were measured using the scanning proton microprobe on the 3 MV Tandetron accelerator at King Fahd University of Petroleum and Minerals. Comparing the distribution profiles of some of the trace elements detected it was possible to suggest an organic, sea origin of these deposits. (Author)

  19. Element analysis of Japanese traditional papers by PIXE method

    International Nuclear Information System (INIS)

    Suzuki, Tatsuya; Yasuda, Keisuke; Tani, Teruhiro

    2000-01-01

    The Japanese papers, 'washi', are made from the bast fibers of the plants. Since washi have the informations of the raw material plants, there is potentiality of the identification of the production place by the element analysis of the washi. Three kinds of washi made of kozo, which have different habitats, were prepared. The elements in their washi were measured by the PIXE. It was confirmed that the amount of elements included in the washi depend on the habitats of their raw material plants. (author)

  20. Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe

    International Nuclear Information System (INIS)

    Vavpetič, P.; Pelicon, P.; Vogel-Mikuš, K.; Grlj, N.; Pongrac, P.; Jeromel, L.; Ogrinc, N.; Regvar, M.

    2013-01-01

    Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological samples in frozen hydrated state using micro-PIXE/STIM/RBS. Sample load-lock system was added to our existing setup to enable us to quickly insert a sample holder with frozen hydrated tissue samples onto a cold goniometer head cooled with liquid nitrogen inside the measuring chamber. Cryotome-cut slices of frozen hydrated plant samples were mounted between two thin silicon nitride foils and then attached to the sample holder. Sufficient thermal contact between silicon nitride foils and sample holder must be achieved, as well as between the sample holder and the cold goniometer head inside the measuring chamber to prevent melting of the samples. Matrix composition of frozen hydrated tissue is consisted mostly of ice. Thinning of the sample as well as water evaporation during high vacuum and proton beam exposure was inspected by the measurements with RBS and STIM method simultaneously with micro-PIXE. For first measuring attempts a standard micro-PIXE configuration for tissue mapping was used with proton beam cross section of 1.2 × 1.2 μm 2 and a beam current of 100 pA. The temperature of the cold goniometer head was kept below 130 K throughout the entire proton beam exposure. First measurements of thin plant tissue samples in frozen hydrated state show minute sample degradation during the 10 h period of micro-PIXE measurements

  1. Analysis of some ancient glass samples unearthed in Sichuan area by PIXE

    International Nuclear Information System (INIS)

    Li Fei; Li Qinghui; Gan Fuxi

    2007-01-01

    Proton induced X-ray emission (PIXE) technique is an effective method for the chemical composition analysis of ancient glass samples without destruction. Chemical composition of the ancient glass samples dated from the Warring States Period (770-476 B.C.) to the Six Dynasties Period (220-589 A.D.), which were unearthed in Sichuan area, was quantitatively determined by the PIXE technique. The results show that the glass Bi (disc) and the glass eye beads of the Warring States Period all belong to the PbO-BaO-SiO 2 system. According to the composition and shape, we infer that these glass Bi and eye beads were made in China. Whereas, the chemical compositions of the glass ear pendants and beads of the Six Dynasties Period are varied, including K 2 O-CaO-SiO 2 , K 2 O-SiO 2 and other glass systems, Based on the obtained results and those from literatures, some questions related to the technical propagation of the ancient Chinese glass are discussed. (authors)

  2. PIXE analysis as a tool for dating of ice cores from the Greenland ice sheet

    International Nuclear Information System (INIS)

    Hansson, H.C.; Swietlicki, E.; Larsson, N.P.O.; Johnsen, S.J.

    1993-01-01

    Sections from the 2037 m long Dye 3 ice core drilled in 1979-1981 in the ice sheet of Southern Greenland were analysed with PIXE. The seven selected sections were from depths between 1778 and 1813 m, which corresponds to a time interval between about 8 500 and 10 000 years B.C. at the end of the last Ice Age. During this time period, fast climatic changes of several degrees centrigrade per century are known to have taken place. The exact time scales of these changes need yet to be verified by renewed measurements using nonconventional stratigraphic dating techniques such as PIXE. The problem is highly relevant for the prediction of climatic changes in our present age. A new sample preparation technique was developed which enables the determination of annual thicknesses of the parts of the ice core representing 10 000-40 000 years before present, where the thickness of the annual ice layers are believed to be less than 2.5 cm. More commonly used techniques of dating, such as measurements of oxygen and hydrogen isotopes δ 18 O and δD, nitrate, acidity or conductivity all have difficulties in resolving annual cycles in thicknesses of less than about 2 cm. The new technique involves sublimation of 18 cm long ice sections, after which the material contained in the ice is deposited on the thin backing. In this way, the material to be analysed is preconcentrated through the removal of the H 2 O, while still retaining the spatial distribution pattern of the various water soluble and insoluble components along the ice core. The resulting spatial resolution of the sublimation technique is estimated to be ±1 mm. A PIXE analysis was performed in contiguous millimeter steps across the sublimated ice sections. Estimations of annual ice layer thicknesses were based on the patterns of seasonal variation along the ice sections for several major and minor elements quantified with PIXE. (orig./TW)

  3. The external beam facility used to characterize corrosion products in metallic statuettes

    International Nuclear Information System (INIS)

    Rizzutto, M.A.; Tabacniks, M.H.; Added, N.; Barbosa, M.D.L.; Curado, J.F.; Santos, W.A.; Lima, S.C.; Melo, H.G.; Neiva, A.C.

    2005-01-01

    To open new possibilities in nuclear applied physics research, mainly for the analysis of art objects in air, an external beam facility was installed at LAMFI (Laboratorio de Analise de Materiais por Feixes Ionicos) of University of Sao Paulo. PIXE measurements were made using an XR-100CR (Si-PIN) X-ray detector pointed to the sample mounted after an approximate 11 mm air path, hence with effective beam energy of 0.9 MeV. This setup was used to characterize the corrosion products of two ethnological metallic statuettes from the African collection of the Museum of Archaeology and Etnology. PIXE analysis of the corrosion free base of one statuette showed that Cu and Zn are the main components of the alloy, while Pb is present in smaller amount. The analysis of some corrosion products showed a Zn:Cu relationship higher than that of the base, evidencing selective corrosion. The main components of the other statuette were Cu and Pb, while S and Zn were found in smaller amounts

  4. Using Tools of Strategic Management in Medical Facilities of Lublin Region

    Directory of Open Access Journals (Sweden)

    Jaworzynska Magdalena

    2017-06-01

    Full Text Available The purpose of this article is to evaluate the use of tools of strategic management in hospitals in Lublin region. The study was conducted among 14 medical entities from the area of Lublin Voivodeship. The survey was addressed to economic directors or chief accountants of health care facilities and sent by post. The questionnaire was also helpful in conducting an in-depth interview as it provided a required structure. As part of the interviews with managers of health care facilities, information beyond the questionnaire was acquired, e.g. about the mission. According to studies, most health care facilities develop strategic plans (71.4%. For 21.4% of the studied facilities, the strategic plan is known mainly to management. In contrast, 28.6% of entities do not have a strategic plan. The presented results of the research can increase the effectiveness of activities in each area of the health care facility, continuous process improvement and rapid response to changes in the environment.

  5. Micro-PIXE in plant sciences: Present status and perspectives

    International Nuclear Information System (INIS)

    Mesjasz-Przybylowicz, Jolanta; Przybylowicz, Wojciech J.

    2002-01-01

    Fundamental processes of plant physiology are affected or regulated by mineral nutrients. Hence understanding the mechanisms of nutrient uptake and their functions in plant metabolism is of fundamental importance in both basic and applied plant studies. The present knowledge of ion uptake mechanisms is based mostly on techniques for bulk analysis, including analysis of small (mg-sized) samples but without spatially resolved results. On the other hand, advanced studies of elemental transport at a cellular level are conducted using techniques with high and very high spatial resolution, but with low sensitivity for elemental analysis. Thus the results obtained are usually restricted to macronutrients or elements present in high quantities. There is a high demand for studies of the functions of trace elements. In addition, it is known that, depending on their concentrations, elements can play different roles in plant life. Studies related to elemental deficiency and toxicity, as well as environmental pollution, require accurate, fully quantitative methods with good spatial resolution. Ideally, these studies should be conducted on organs and tissues as far down as the cellular level. This is where micro-PIXE has been applied until present and can in the near future play a much more important role. Progress is subject to closer collaboration between plant biologists and the PIXE community in terms of addressing problems of specimen preparation, refinement of analytical protocols such as quantitative elemental mapping and the interpretation of results

  6. Micro PIXE investigations. Time sequencing studies in degenerative diseases

    International Nuclear Information System (INIS)

    Watt, F.; Minqin, R.; Patricia Thong ps

    1999-01-01

    The simultaneously applied techniques of Particle Induced X-ray Emission (PIXE), Rutherford Backscattering Spectrometry (RBS) and Scanning Transmission Ion Microscopy (STIM), have been successful in mapping and quantifying trace elements during the progression of several human diseases, in particular those degenerative diseases which have a corresponding animal model. In atherosclerosis, iron has been shown to be present in increased concentrations at the early stage of lesion formation, and when the animal model has been kept anaemic, the artery wall shows a reduced uptake of iron and a delay in lesion formation compared with controls. In Parkinson's disease, there is also an increased concentration of iron in the substantia nigra region of the brain. Although the increase in bulk iron appears to lag behind the dopaminergic cell death, we have detected an increase in localized deposits of iron at the onset of cell death. These two results infer that iron may play a role in both diseases, perhaps through the mediation of free radicals. The induction of epilepsy through the injection of kainic acid has shown that the cell death is accompanied by an increase in calcium levels as early as one day after injection. The increase in calcium is consistent with activation of phospholipase A 2 and free radical damage. (author)

  7. PIXE/PIGE characterisation of emeralds using an external micro-beam

    International Nuclear Information System (INIS)

    Calligaro, T.; Dran, J.-C.; Poirot, J.-P.; Querre, G.; Salomon, J.; Zwaan, J.C.

    2000-01-01

    A large collection of emeralds of various occurrences has been analysed by PIXE/PIGE in view to establish a compositional database. Major elements (Be, Si, Al) and trace elements (Li, F, Na, Mg, Ca, Rb, Cs and transition metals) are determined using an external 3 MeV proton micro-beam. Elemental micro-mapping permits to select the useful provenance tracers. This database was applied to infer the origin of several ancient emeralds set on historical jewels

  8. Quantitative assay of element mass inventories in single cell biological systems with micro-PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Ogrinc, Nina [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); LOTRIČ Metrology, Selca 163, SI-4227 Selca (Slovenia); Pelicon, Primož, E-mail: primoz.pelicon@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vavpetič, Primož; Kelemen, Mitja; Grlj, Nataša; Jeromel, Luka [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Tomić, Sergej [Medical Faculty of the Military Medical Academy, University of Defense, Crnotravska 17, Belgrade (Serbia); Čolić, Miodrag [Medical Faculty of the Military Medical Academy, University of Defense, Crnotravska 17, Belgrade (Serbia); Medical Faculty, University of Niš, Boulevard of Dr. Zoran Djindjić 81, 18000 Niš (Serbia); Beran, Alfred [Dipartimento di Oceanografia Biologica, Istituto Nazionale di Oceanografia e Geofisica Sperimentale, Via Auguste Piccard 54, 34151 Trieste (Italy)

    2013-07-01

    Elemental concentrations in micro-PIXE (Particle Induced X-ray Emission) maps of elements in biological tissue slices have been determined using auxiliary information on the sample matrix composition from EBS (Elastic Backscattering Spectroscopy) and STIM (Scanning Transmission Ion Microscopy). The thin sample approximation may be used for evaluating micro-PIXE data in cases, where X-ray absorption in the sample can be neglected and the mass of elements in a selected area can be estimated. The resulting sensitivity amounts to an impressive 10{sup −12} g of the selected elements. Two cases are presented as examples. In the first, we determined the total mass of gold nanoparticles internalized by human monocyte-derived dendritic cells (MDDC). In the second, an inventory of the mass of elements in the micro-particulate material adsorbed at the wall of the lorica of the microzooplankton species Tintinnopsis radix has been created.

  9. Quantitative assay of element mass inventories in single cell biological systems with micro-PIXE

    International Nuclear Information System (INIS)

    Ogrinc, Nina; Pelicon, Primož; Vavpetič, Primož; Kelemen, Mitja; Grlj, Nataša; Jeromel, Luka; Tomić, Sergej; Čolić, Miodrag; Beran, Alfred

    2013-01-01

    Elemental concentrations in micro-PIXE (Particle Induced X-ray Emission) maps of elements in biological tissue slices have been determined using auxiliary information on the sample matrix composition from EBS (Elastic Backscattering Spectroscopy) and STIM (Scanning Transmission Ion Microscopy). The thin sample approximation may be used for evaluating micro-PIXE data in cases, where X-ray absorption in the sample can be neglected and the mass of elements in a selected area can be estimated. The resulting sensitivity amounts to an impressive 10 −12 g of the selected elements. Two cases are presented as examples. In the first, we determined the total mass of gold nanoparticles internalized by human monocyte-derived dendritic cells (MDDC). In the second, an inventory of the mass of elements in the micro-particulate material adsorbed at the wall of the lorica of the microzooplankton species Tintinnopsis radix has been created

  10. The quantitative analysis of 163Ho source by PIXE

    International Nuclear Information System (INIS)

    Sera, K.; Ishii, K.; Fujioka, M.; Izawa, G.; Omori, T.

    1984-01-01

    We have been studying the electron-capture in 163 Ho as a method for determining the mass of electron neutrino. The 163 Ho sources were produced with the 164 Dy(p,2n) reaction by means of a method of internal irradiation 2 ). We applied the PIXE method to determine the total number of 163 Ho atoms in the source. Proton beams of 3 MeV and a method of ''external standard'' were employed for nondestructive analysis of the 163 Ho source as well as an additional method of ''internal standard''. (author)

  11. Analysis of desert rose using PIXE and RBS techniques

    International Nuclear Information System (INIS)

    Al-Kofahi, M.M.; Hallak, A.B.; Al-Juwair, H.A.; Saafin, A.K.

    1993-01-01

    Particle-induced x-ray emission (PIXE) and Rutherford backscattering spectrometry (RBS) were used to analyse desert rose geological samples. Samples from the rose core and from the rose peripherals were studied. All samples were found to contain C, N, O, Na, Mg, Si, S, Cl, K, Ca, Ti, Mn, Fe and Sr. Core samples were found to contain more silicon than peripheral samples. The extra silicon in the rose core may suggest a mechanism for the formation of the rose through crystal growth on a seed of silicon. (author)

  12. Application of PIXE in pollution control of the Matola River in Mozambique-analysis of fish scales

    Energy Technology Data Exchange (ETDEWEB)

    Guambe, J.F. [Freshwater Research Unit, Department of Zoology, University of Cape Town, Private Bag, Rondebosch 7701 (South Africa); Departamento de Fisica, Universidade Edouardo Mondlane, C.P. 257, Maputo (Mozambique); Materials Research Department, iThemba LABS, P.O. Box 722, Somerset West 7129 (South Africa); Mars, J.A., E-mail: marsja@cput.ac.za [Faculty of Health and Wellness Sciences, Cape Peninsula University of Technology, P.O. Box 1906, Bellville 7535 (South Africa); Day, J. [Freshwater Research Unit, Department of Zoology, University of Cape Town, Private Bag, Rondebosch 7701 (South Africa)

    2012-02-15

    Since PIXE is able to distinguish concentrations of elements at very small spatial scales, it can be used for estimating levels of metal pollution in biological material. This paper provides a preliminary report of a pilot study on the use of PIXE for the identification and quantification of elements (Al (3 wt%), Si 0.5 wt%), S (1.5 wt%), Cl (15 ppm), Mn (5 ppm), Fe (50 ppm), Ni (3 ppm), Zn (2 ppm), Rb (2 ppm), Sr (800 ppm) and Se (3 ppm)) in scales of the estuarine fish Pomadasys kaakan caught in the Matola River upstream from the Maputo estuary and, downstream of an aluminium smelter. Concentrations of both aluminium and sulphur were high (3 wt% and 1.5 wt%, respectively).

  13. Non-linearity issues and multiple ionization satellites in the PIXE portion of spectra from the Mars alpha particle X-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, John L., E-mail: icampbel@uoguelph.ca; Heirwegh, Christopher M.; Ganly, Brianna

    2016-09-15

    Spectra from the laboratory and flight versions of the Curiosity rover’s alpha particle X-ray spectrometer were fitted with an in-house version of GUPIX, revealing departures from linear behavior of the energy-channel relationships in the low X-ray energy region where alpha particle PIXE is the dominant excitation mechanism. The apparent energy shifts for the lightest elements present were attributed in part to multiple ionization satellites and in part to issues within the detector and/or the pulse processing chain. No specific issue was identified, but the second of these options was considered to be the more probable. Approximate corrections were derived and then applied within the GUAPX code which is designed specifically for quantitative evaluation of APXS spectra. The quality of fit was significantly improved. The peak areas of the light elements Na, Mg, Al and Si were changed by only a few percent in most spectra. The changes for elements with higher atomic number were generally smaller, with a few exceptions. Overall, the percentage peak area changes are much smaller than the overall uncertainties in derived concentrations, which are largely attributable to the effects of rock heterogeneity. The magnitude of the satellite contributions suggests the need to incorporate these routinely in accelerator-based PIXE using helium beams.

  14. Characterization of Ultra thin chromium layers deposited ou to SiO2 using the Le-PIXE and the RB S techniques

    International Nuclear Information System (INIS)

    Zahraman, K.; Nsouli, B.; Roumie, M.

    2007-01-01

    In this paper, we demonstrate the ability of the Le-PIXE (Low Energy PIXE) technique, using proton energies < 1 MeV, for the monitoring of the thickness and the thickness uniformity of ultra thin (0.5 nm < t < 20 nm) chromium layers deposited onto quartz substrates. Chromium is a good candidate for obtaining conductive ultra thin layers on insulator substrates such as quartz (SiO2). The resistivity of such layers is highly related to the quality of the deposited chromium film. In order to optimize the deposition process, there is a need for rapid and accurate monitoring of such films (film thickness, thickness uniformity over a big surface...). The acquisition time needed to obtain results with less than 3-4 % precision was 5 minutes for the thinnest layers. The validation for the use of the Le-PIXE technique was checked by means of conventional RB S technique.

  15. A comparison between PIXE and ICP-AES measurements of metals in aerosol particulate collected in urban and marine sites in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Traversi, R.; Becagli, S. [Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, I-50019 Sesto F.no, Florence (Italy); Calzolai, G.; Chiari, M.; Giannoni, M. [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Lucarelli, F., E-mail: lucarelli@fi.infn.it [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Nava, S. [Department of Physics and Astronomy, University of Florence and I.N.F.N., Florence, Via G. Sansone 1, I-50019 Sesto F.no, Florence (Italy); Rugi, F.; Severi, M.; Udisti, R. [Department of Chemistry “Ugo Schiff”, University of Florence, Via della Lastruccia 3, I-50019 Sesto F.no, Florence (Italy)

    2014-01-01

    PIXE and ICP-AES techniques are largely used in atmospheric aerosol studies. Since PIXE is able to provide the total elemental concentrations, while ICP-AES results depend on the extraction conditions, parallel PIXE and ICP-AES measurements of Fe, Al, Cu, Pb, Mn, Cr, Ni, V, As on PM10 and PM2.5 samples were compared. Two extraction procedures were applied to samples from 5 sites at different anthropization level in Italy: a “weak” extraction (HNO{sub 3} at pH = 1.5) and a “strong” extraction (micro-wave oven in HNO{sub 3} and H{sub 2}O{sub 2} – following EU rules). The amount of the metal extracted in the different conditions resulted to be strongly dependent on the sampling site, on the main sources of the particle (crustal or anthropic) containing the metal and on the sampled size class.

  16. Distribution of metals in vacuum residuums, asphaltenes and maltenes by PIXE

    International Nuclear Information System (INIS)

    Romero G, E.T.; Camacho M, V.; Sanchez B, A.C.; Lopez M, J.; Ramirez T, J.J.; Villasenor S, P.; Aspiazu F, J.A.

    2001-01-01

    The PIXE technique for determining directly the distribution and abundance of trace metals in vacuum residuum, asphaltenes and maltenes separated with n-alkanes (C 5 -C 8 ) is used. The metal content of petroleum derivatives revealed that the vacuum residuum contains iron, aluminium, vanadium and nickel mainly, while that the asphaltenes and maltenes maintain inside of their composition only preferably the vanadium and nickel as majority elements. (Author)

  17. Development and applications of STIM- and PIXE-tomography: A review

    International Nuclear Information System (INIS)

    Michelet, C.; Barberet, P.; Moretto, P.; Seznec, H.

    2015-01-01

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  18. Non-destructive provenance differentiation of prehistoric pigments by external PIXE

    International Nuclear Information System (INIS)

    Beck, L.; Salomon, H.; Lahlil, S.; Lebon, M.; Odin, G.P.; Coquinot, Y.; Pichon, L.

    2012-01-01

    The elemental analysis of minerals/rocks has been often used for the determination of their geological origin. When these natural rocks were exploited by prehistoric civilizations as objects, weapons, or pigments, the composition of the minerals can provide information on the mobility, the exchanges and the interaction between groups of population. In this paper, we will present results obtained from archaeological samples of prehistoric pigments, mainly iron and manganese oxides. PIXE analysis has been applied to samples of the prehistoric cave “La grotte du Renne” in Arcy-sur-Cure, France (Chatelperronian, 38,000–34,000 BP). Because most of the archaeological objects are decorated or display some use marks, it is not possible to take samples. Consequently, we have used a non-destructive technique thanks to the external beam of AGLAE (C2RMF, Paris). In order to improve the limits of detection (LOD less than 10 ppm from Cu to Sb), a metal absorber has been placed on the X-ray detector to preferentially filter the Fe–K or Mn–K lines. Based on the quantitative analysis of major and trace elements, we have obtained groups of compositions corresponding to different geological sources. We demonstrate in this study that it is possible to extend PIXE analysis to the characterization of prehistoric pigments such as iron and manganese oxides for differentiating potential sources of pigments in archaeological contexts.

  19. Development and applications of STIM- and PIXE-tomography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Michelet, C., E-mail: michelet@cenbg.in2p3.fr; Barberet, P., E-mail: barberet@cenbg.in2p3.fr; Moretto, P., E-mail: moretto@cenbg.in2p3.fr; Seznec, H., E-mail: herve.seznec@cenbg.in2p3.fr

    2015-11-15

    In combination with nuclear microprobes, STIM and PIXE tomography offer non-destructive quantitative three-dimensional characterization of microscopic samples. STIM tomography provides 3D density maps of the analyzed sample with sub-micrometer resolution and PIXE tomography is one of the only methods allowing a quantification of trace elements in three dimensions. These tomography techniques have been developed in several microbeam laboratories around the world since the 80’s. Nevertheless, despite a huge interest in mapping the inner content of a sample without destroying it, the use of ion beam tomography has been limited to a few studies up to now. This comes from the specific requirements of this kind of experiments, i.e. specific experimental set-up (rotation of the sample during analysis) and reconstruction software, making this type of experiments difficult to handle and relatively long. For a few years, efforts have been made to facilitate the implementation of these techniques and reduce the duration of data acquisition: new detectors and new algorithms were proposed. After an introduction to ion beam tomography techniques and to the first developments made in that field, the experimental and data processing specificities of this 3D imaging approach will be discussed. Finally, examples of recent applications to biology and material science are presented, as well as related techniques developed in the field of microbeam 3D imaging.

  20. Bronze analysis by k0-NAA and PIXE

    International Nuclear Information System (INIS)

    Arana, G.; Waetjen, U.; Ingelbrecht, C.; Robouch, P.

    2003-01-01

    Five copper alloys were prepared with modern powder metallurgical processes in the frame of the European project 'Improvement of Means of Measurement on Archaeological Copper-Alloys for Characterisation and Conservation (IMMACO)' and certified for As, Pb, Sn and Zn mass fractions. Similar in their composition to archaeological bronze alloys, these Certified Reference Materials (CRMs) are to be used for calibration of XRF instruments for characterization of archaeological samples either in the laboratory or in the field. Successful contribution of non-destructive analytical methods (k 0 -NAA and PIXE) to the IMMACO project and to the certification of the five reference materials is presented. (author)

  1. Comparison of PIXE and XRF analysis of airborne particulate matter samples collected on Teflon and quartz fibre filters

    Science.gov (United States)

    Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.

    2018-02-01

    Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.

  2. Characterisation of early medieval frescoes by μ-PIXE, SEM and Raman spectroscopy

    International Nuclear Information System (INIS)

    Zucchiatti, A.; Prati, P.; Bouquillon, A.; Giuntini, L.; Massi, M.; Migliori, A.; Cagnana, A.; Roascio, S.

    2004-01-01

    We have studied the VIII-IX century frescoes of the Longobard temple of Cividale del Friuli in Italy with noninvasive sampling and, for the first time in such a context, with high chemical and spatial sensitivity techniques (PIXE, SEM and Raman). Results demonstrate richness of manufacturing details and integrate in a substantial way the historic and artistic framework of this early medieval monument

  3. Characterisation of early medieval frescoes by {mu}-PIXE, SEM and Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zucchiatti, A. E-mail: zucc@ge.infn.it; Prati, P.; Bouquillon, A.; Giuntini, L.; Massi, M.; Migliori, A.; Cagnana, A.; Roascio, S

    2004-06-01

    We have studied the VIII-IX century frescoes of the Longobard temple of Cividale del Friuli in Italy with noninvasive sampling and, for the first time in such a context, with high chemical and spatial sensitivity techniques (PIXE, SEM and Raman). Results demonstrate richness of manufacturing details and integrate in a substantial way the historic and artistic framework of this early medieval monument.

  4. Pixe analysis of trace elements in tissues of rats treated with anticonvulsants

    Science.gov (United States)

    Hurd, R. W.; Van Rinsvelt, H. A.; Kinyua, A. M.; O'Neill, M. P.; Wilder, B. J.; Houdayer, A.; Hinrichsen, P. F.

    1987-04-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex.

  5. PIXE analysis of trace elements in tissues of rats treated with anticonvulsants

    Energy Technology Data Exchange (ETDEWEB)

    Hurd, R.W.; Van Rinsvelt, H.A.; Kinyua, A.M.; O' Neill, M.P.; Wilder, B.J.; Houdayer, A.; Hinrichsen, P.F.

    1987-04-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex.

  6. PIXE analysis of trace elements in tissues of rats treated with anticonvulsants

    International Nuclear Information System (INIS)

    Hurd, R.W.; Van Rinsvelt, H.A.; Kinyua, A.M.; O'Neill, M.P.; Wilder, B.J.; Florida Univ., Gainesville; Houdayer, A.; Hinrichsen, P.F.

    1987-01-01

    Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex. (orig.)

  7. The quantitative analysis of Bowen's kale by PIXE using the internal standard

    International Nuclear Information System (INIS)

    Navarrete, V.R.; Izawa, G.; Shiokawa, T.; Kamiya, M.; Morita, S.

    1978-01-01

    The internal standard method was used for non-destructive quantitative determination of trace elements by PIXE. The uniform distribution of the internal standard element in the Bowen's kale powder sample was obtained by using homogenization technique. Eleven elements are determined quantitatively for the sample prepared into self-supporting targets having lower relative standard deviations than non-self-supporting targets. (author)

  8. Characterization of Thai Amulets A PIXE Study

    International Nuclear Information System (INIS)

    Won-In, K.; Suksawang, S.; Intarasiri, S.; Thongleurm, Chom; Kamwanna, T.; Dararutana, P.

    2011-01-01

    The Thai amulets that created in an image of Lord Buddha meditation were made to explain the Dharma of Buddha and believed to bless every life in this world for good karma. Phra Somdej Wat Rakhang amulet is the top of the five most famous Thai amulets. There are many molds with various compositions. In this work, it was the first time that X-ray fluorescence spectrometry methods; scanning electron microscope cooperated with energy dispersive X-ray fluorescence spectrometer (SEM/EDS) and particle induced X-ray emission spectroscopy (PIXE) were carried out to analyze their compositions. Two samples were collected from different molds. Results revealed C, Ca and Si were main composition. The differences in their compositions have been used to identify and characterize for each molds

  9. Comparative trace elemental analysis of cancerous and non-cancerous tissues of rectal cancer patients using PIXE

    Science.gov (United States)

    Naga Raju, G. J.; Sarita, P.; Murthy, K. S. R.

    2017-08-01

    Particle Induced X-ray Emission (PIXE), an accelerator based analytical technique has been employed in this work for the analysis of trace elements in the cancerous and non-cancerous tissues of rectal cancer patients. A beam of 3 MeV protons generated from 3 MV Pelletron accelerator at the Ion Beam Laboratory of Institute of Physics, Bhubaneswar, India was used as projectile to excite the atoms present in the tissues samples. PIXE technique, with its capability to detect simultaneously several elements present at very low concentrations, offers an excellent tool for trace element analysis. The characteristic X-rays emitted by the samples were recorded by a high resolution Si (Li) detector. On the basis of the PIXE spectrum obtained for each sample, the elements Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, and Br were identified and their relative concentrations were estimated in the cancerous and non-cancerous tissues of rectum. The levels of Mn, Fe, Co, Cu, Zn, and As were higher (p < 0.005) while the levels of Ca, Cr and Ni were lower (p < 0.005) in the cancer tissues relative to the normal tissues. The alterations in the levels of the trace elements observed in the present work are discussed in this paper with respect to their potential role in the initiation, promotion and inhibition of cancer of the rectum.

  10. Trace element finger printing of emeralds by PIXE and PIGE

    International Nuclear Information System (INIS)

    Ma Xinpei; Palmer, G.R.; MacArthur, J.D.

    1990-01-01

    The concentrations of 18 major- and minor-elements in 12 Emeralds from different mines and two synthetic ones are measured with proton induced X-ray emission (PIXE) and γ-ray emission (PIGE). The concentration and distribution of 18 elements are used to establish the characteristic finger print pattern of each Emerald. With the help of cluster analysis of SYSTAT statistical package for IBMPC, these finger prints are analysed, from which a quantitative description of the dissimilarities between Emeralds can be given

  11. Assessment of metal sorption mechanisms by aquatic macrophytes using PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Módenes, A.N., E-mail: anmodenes@yahoo.com.br [Department of Chemical Engineering-Postgraduate Program, West Parana State University, Campus of Toledo, rua da Faculdade 645, Jd. La Salle, 85903-000 Toledo, PR (Brazil); Espinoza-Quiñones, F.R.; Santos, G.H.F.; Borba, C.E. [Department of Chemical Engineering-Postgraduate Program, West Parana State University, Campus of Toledo, rua da Faculdade 645, Jd. La Salle, 85903-000 Toledo, PR (Brazil); Rizzutto, M.A. [Physics Institute, University of São Paulo, Rua do Matão s/n, Travessa R 187, 05508-900 São Paulo, SP (Brazil)

    2013-10-15

    Highlights: • Divalent metal ion removals by Egeria densa biosorbent. • Multielements concentrations in biosorbent samples by PIXE analysis. • Elements mass balance in liquid and solid phase before and after metal removals. • Assessment of the mechanisms involved in Cd{sup 2+} and Zn{sup 2+} removal by biosorbent. • Confirmation of the signature of ion exchange process in metal removal. -- Abstract: In this work, a study of the metal sorption mechanism by dead biomass has been performed. All batch metal biosorption experiments were performed using the aquatic macrophyte Egeria densa as biosorbent. Divalent cadmium and zinc solutions were used to assess the sorption mechanisms involved. Using a suitable equilibrium time of 2 h and a mixture of 300 mg biosorbent and 50 mL metal solution at pH 5, monocomponent sorption experiments were performed. In order to determine the residual amounts of metals in the aqueous solutions and the concentrations of removed metals in the dry biomass, Particle Induced X-ray Emission (PIXE) measurements in thin and thick target samples were carried out. Based on the strong experimental evidence from the mass balance among the major elements participating in the sorption processes, an ion exchange process was identified as the mechanism responsible for metal removal by the dry biomass.

  12. Integrated bio-photonics to revolutionize health care enabled through PIX4life and PIXAPP

    Science.gov (United States)

    Jans, Hilde; O'Brien, Peter; Artundo, Iñigo; Porcel, Marco A. G.; Hoofman, Romano; Geuzebroek, Douwe; Dumon, Pieter; van der Vliet, Marcel; Witzens, Jeremy; Bourguignon, Eric; Van Dorpe, Pol; Lagae, Liesbet

    2018-02-01

    Photonics has become critical to life sciences. However, the field is far from benefiting fully from photonics' capabilities. Today, bulky and expensive optical systems dominate biomedical photonics, even though robust optical functionality can be realized cost-effectively on single photonic integrated circuits (PICs). Such chips are commercially available mostly for telecom applications, and at infrared wavelengths. Although proof-of-concept demonstrations for PICs in life sciences, using visible wavelengths are abundant, the gating factor for wider adoption is limited in resource capacity. Two European pilot lines, PIX4life and PIXAPP, were established to facilitate European R and D in biophotonics, by helping European companies and universities bridge the gap between research and industrial development. Through creation of an open-access model, PIX4life aims to lower barriers to entry for prototyping and validating biophotonics concepts for larger scale production. In addition, PIXAPP enables the assembly and packaging of photonic integrated circuits.

  13. Optimization of PIXE quantitative system to assist the traceability of pearl and other gemstones

    Energy Technology Data Exchange (ETDEWEB)

    Murao, S., E-mail: s.murao@aist.go.jp [National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, (Japan); Sera, K. [Cyclotron Research Center, Iwate Medical University, Takizawa, Iwate (Japan); Goto, S.; Takahashi, C. [Takizawa Laboratory, Japan Radioisotope Association, Takizawa, Iwate (Japan); Cartier, L. [Department of Environmental Science, University of Basel (Switzerland); Nakashima, K. [Yamagata University, Yamagata, (Japan)

    2013-07-01

    Full text: A recent rise of social attention towards ethical consumerism, ethical jewellery, blood diamonds and the traceability of gemstones has challenged scientists to construct analytical systems to deliver in line with such expectations by offering traceability solutions. It is important to develop traceability protocols for gemstones and pearls that are ethically traded, as this will further encourage members of the trade to engage in ethical and fair trade practices. Of various kinds of available methods, Proton/particle Induced X-ray Emission (PIXE) seems to be robust and promising in this context because of its trace element analysis capabilities without destruction. The authors conducted both vacuum and in-air experiments to optimize conditions to identify important peaks and to quantify the signals that correspond to gemstone materials from specific geographic origins. PIXE results for cultured pearls from Micronesia and commercial-quality crystals from Pakistan, both sources of fair trade gemstone materials, will be presented. (author)

  14. Optimization of PIXE quantitative system to assist the traceability of pearl and other gemstones

    International Nuclear Information System (INIS)

    Murao, S.; Sera, K.; Goto, S.; Takahashi, C.; Cartier, L.; Nakashima, K.

    2013-01-01

    Full text: A recent rise of social attention towards ethical consumerism, ethical jewellery, blood diamonds and the traceability of gemstones has challenged scientists to construct analytical systems to deliver in line with such expectations by offering traceability solutions. It is important to develop traceability protocols for gemstones and pearls that are ethically traded, as this will further encourage members of the trade to engage in ethical and fair trade practices. Of various kinds of available methods, Proton/particle Induced X-ray Emission (PIXE) seems to be robust and promising in this context because of its trace element analysis capabilities without destruction. The authors conducted both vacuum and in-air experiments to optimize conditions to identify important peaks and to quantify the signals that correspond to gemstone materials from specific geographic origins. PIXE results for cultured pearls from Micronesia and commercial-quality crystals from Pakistan, both sources of fair trade gemstone materials, will be presented. (author)

  15. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Yumoto, S.; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-01-01

    To investigate the cause of Alzheimer's disease (senile dementia of Alzheimer's disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer's disease using heavy ion (5 MeV Si 3+ ) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si 2+ ) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer's disease using 5 MeV Si 3+ microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer's disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  16. PIXE multivariate statistics and OSL investigation for the classification and dating of archaeological pottery excavated at Tell Al-Rawda site, Syria

    Energy Technology Data Exchange (ETDEWEB)

    Bakraji, E.H., E-mail: cscientificl@aec.org.sy [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic); Rihawy, M.S. [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic); Castel, C. [CNRS – Maison de l’Orient et de la Méditerranée, Laboratoire “Archéorient”, CNRS/Université Lumière-Lyon 2 (France); Abboud, R. [Archaeometry Laboratory, Chemistry Department, Atomic Energy Commission of Syria, P. O. Box 6091, Damascus (Syrian Arab Republic)

    2015-03-15

    Highlights: •PIXE and OSL methods were used to classify and date pottery from Tell Al-Rawda site. •Three groups were classified using PIXE, which suggest different sources of the clay. •OSL was used for dating the site and the date found was consistent with typology. -- Abstract: Particle Induced X-ray Emission (PIXE) technique has been utilised to study 48 Syrian ancient pottery fragments taken from excavations at Tell Al-Rawda site. Eighteen elements (Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe, Ni, Zn, As, Br, Rb, Sr, Y, and Pb) were determined. The elements concentrations have been processed using two multivariate statistical methods, to classify the pottery where one main group and other two small groups were defined. In addition, four samples from different places on the site were subjected to optically stimulated luminescence (OSL) dating. The average age obtained using a single aliquot regeneration (SAR) protocol was found to be 4350 ± 240 year.

  17. PIXE multivariate statistics and OSL investigation for the classification and dating of archaeological pottery excavated at Tell Al-Rawda site, Syria

    International Nuclear Information System (INIS)

    Bakraji, E.H.; Rihawy, M.S.; Castel, C.; Abboud, R.

    2015-01-01

    Highlights: •PIXE and OSL methods were used to classify and date pottery from Tell Al-Rawda site. •Three groups were classified using PIXE, which suggest different sources of the clay. •OSL was used for dating the site and the date found was consistent with typology. -- Abstract: Particle Induced X-ray Emission (PIXE) technique has been utilised to study 48 Syrian ancient pottery fragments taken from excavations at Tell Al-Rawda site. Eighteen elements (Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe, Ni, Zn, As, Br, Rb, Sr, Y, and Pb) were determined. The elements concentrations have been processed using two multivariate statistical methods, to classify the pottery where one main group and other two small groups were defined. In addition, four samples from different places on the site were subjected to optically stimulated luminescence (OSL) dating. The average age obtained using a single aliquot regeneration (SAR) protocol was found to be 4350 ± 240 year

  18. A minisum model with forbidden regions for locating a semi-desirable facility in the plane

    DEFF Research Database (Denmark)

    Brimberg, Jack; Juel, Henrik

    -desirable facility which accounts for the service costs by a standard minisum objective with arbitrary travel distance function. The social costs are imputed by specifying around each demand point or population center a convex forbidden region, also defined by an arbitrary distance metric, in which the new facility...... may not be located. A general solution algorithm is suggested, and the methodology applied to circular forbidden regions and special travel distance functions....

  19. Trace element analysis of the Otani Collection's Dunhuang and Turfan manuscripts by PIXE

    International Nuclear Information System (INIS)

    Kohno, M.; Yoshida, K.; Moritani, K.; Norizawa, K.; Enami, K.; Kasajima, H.; Ueyama, D.; Takada, J.; Matsushita, R.

    1999-01-01

    In order to classify the Otani Collection's Dunhuang and Turfan manuscripts, their trace elements were analyzed by PIXE. The paper samples of these manuscripts were fallen off when they were photographed for a CD-ROM catalog. These samples were very small and their size was less than several millimeters. In addition, some paper fragments dating from the late Edo-era of Japan and the late Qing Dynasty of China, and modern Japanese handmade paper were analyzed using PIXE and NAA. Quite interesting results were obtained when analyzing the trace elements - Na, Mg, Al, Si, S, Cl, K, Ca, Sc, Mn, Fe, Cu, Zn, As, Br, Sr, Ba, Pb, La, Sm. It was found that Dunhuang and Turfan papers of the Otani Collection were characterized by its highest iron and bromine content. The reason of the highest iron content probably originates in their making process and/or depends on their preservative environment. On the other hand, it became clear as for the highest bromine content that the origin is from fumigation of methyl bromide. (author)

  20. Grain-size effects on PIXE and INAA analysis of IAEA-336 lichen reference material

    International Nuclear Information System (INIS)

    Marques, A.P.; Freitas, M.C.; Wolterbeek, H.Th.; Verburg, T.G.; Goeij, J.J.M. de

    2007-01-01

    IAEA-336 lichen certified reference material was used to compare outcomes from INAA and PIXE elemental analyses, in relationship with grain size. The IAEA material (grain size <125 μm) was ground and sieved through nylon nets with 64 μm, 41 μm and 20 μm pores. Particle sizes were determined by Laser Light Scattering technique: the data indicate that, after sieving, the IAEA-336 lichen reference material's particle size distribution follows a bimodal distribution, which is turning more and more monomodal after further fine sieving. Replicates of each fraction were analysed by INAA and PIXE. Results for Cl, K, Mn, Fe and Zn by both techniques were compared by application of z-values tested against the criterion vertical bar z vertical bar < 3 for approval of results at the 99.7% confidence level. Under the conditions of this study, the limited amount of lichen material as 'seen' in the PIXE analysis and the grain size distribution in the lichen material were no causes of measurable differences between the results of both techniques. However, fractionation into smaller grain sizes showed to be associated with lower element content, for Na, Cl, K, Mn and Sr even up to a factor of 2. The observed increases of the proportion of algae in the smaller grain-size fractions and the possible accumulation capacity for certain elements in the fungal part of the lichen may explain the observed phenomenon. The sieving process and consequently the discarding of part of the material have lead to a change of the properties of the original sample, namely algae/fungus percentage and elemental contents

  1. A minisum model with forbidden regions for locating a semi-desirable facility in the plane

    DEFF Research Database (Denmark)

    Juel, Henrik; Brimberg, Jack

    1998-01-01

    -desirable facility that accounts for the service costs by a standard minisum objective with arbitrary travel distance function. The social costs are imputed by specifying around each demand point or population center a convex forbidden region, also defined by an arbitrary distance metric, in which the new facility...... may not be located. A general solution algorithm is suggested, and the methodology is applied to circular forbidden regions and special travel distance functions....

  2. Evaluation of caries progression in dentin treated by fluoride-containing materials using an in-air micro-PIGE and micro-PIXE measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, H., E-mail: yhiroko@dent.osaka-u.ac.jp [Department of Restorative Dentistry and Endodontology, Osaka University Graduate School of Dentistry, 1-8 Yamada-Oka, Suita 565-0871 (Japan); Iwami, Y.; Yagi, K.; Hayashi, M. [Department of Restorative Dentistry and Endodontology, Osaka University Graduate School of Dentistry, 1-8 Yamada-Oka, Suita 565-0871 (Japan); Komatsu, H.; Okuyama, K.; Matsuda, Y. [Graduate School of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586 (Japan); Yasuda, K. [The Wakasa Wan Energy Research Center, 64-52-1 Nagatani, Tsuruga 914-0192 (Japan)

    2015-04-01

    It is well-known that fluorine (F) is involved in the progression of caries. The evaluation of caries progression has conventionally been based on the change in mineral content using transverse microradiography (TMR). The purpose of this study was to evaluate the progression of dentinal caries by the change in calcium (Ca) content using Particle-Induced Gamma-ray Emission/Particle-Induced X-ray Emission (PIGE/PIXE) techniques at the Wakasa Wan Energy Research Center. We also assessed the relationship between caries progression rate and the concentration of F penetration into dentin from dental fluoride-containing materials (FCMs). Dentin sections of six extracted human teeth were prepared to obtain various amounts of F uptake using three types of FCMs. F and Ca distribution of specimens were obtained using PIGE/PIXE techniques. After evaluation, the specimens were immersed in 10 ml of demineralizing solution (pH 4.5) to simulate caries attack. To estimate caries progression rates, the same portions of the specimens were evaluated after caries attack treatment using PIGE/PIXE. A negative correlation between the F uptake in dentin and the rate of caries progression was observed. Therefore, caries progression in dentin was reduced by increasing the amount of F uptake from FCMs. This demonstrates that PIGE/PIXE techniques are valuable for estimating caries progression rates.

  3. Evaluation of caries progression in dentin treated by fluoride-containing materials using an in-air micro-PIGE and micro-PIXE measurement system

    International Nuclear Information System (INIS)

    Yamamoto, H.; Iwami, Y.; Yagi, K.; Hayashi, M.; Komatsu, H.; Okuyama, K.; Matsuda, Y.; Yasuda, K.

    2015-01-01

    It is well-known that fluorine (F) is involved in the progression of caries. The evaluation of caries progression has conventionally been based on the change in mineral content using transverse microradiography (TMR). The purpose of this study was to evaluate the progression of dentinal caries by the change in calcium (Ca) content using Particle-Induced Gamma-ray Emission/Particle-Induced X-ray Emission (PIGE/PIXE) techniques at the Wakasa Wan Energy Research Center. We also assessed the relationship between caries progression rate and the concentration of F penetration into dentin from dental fluoride-containing materials (FCMs). Dentin sections of six extracted human teeth were prepared to obtain various amounts of F uptake using three types of FCMs. F and Ca distribution of specimens were obtained using PIGE/PIXE techniques. After evaluation, the specimens were immersed in 10 ml of demineralizing solution (pH 4.5) to simulate caries attack. To estimate caries progression rates, the same portions of the specimens were evaluated after caries attack treatment using PIGE/PIXE. A negative correlation between the F uptake in dentin and the rate of caries progression was observed. Therefore, caries progression in dentin was reduced by increasing the amount of F uptake from FCMs. This demonstrates that PIGE/PIXE techniques are valuable for estimating caries progression rates

  4. PIXE and PGAA - Complementary methods for studies on ancient glass artefacts (from Byzantine, late medieval to modern Murano glass)

    Science.gov (United States)

    Constantinescu, Bogdan; Cristea-Stan, Daniela; Szőkefalvi-Nagy, Zoltán; Kovács, Imre; Harsányi, Ildikó; Kasztovszky, Zsolt

    2018-02-01

    Combined external milli-beam Particle Induced X-ray Emission (PIXE) and Prompt Gamma Activation Analysis (PGAA) analysis was applied to characterize the composition of paste and colorants from some fragments of Byzantine bracelets (10th-12th Centuries AD), late medieval (17th-18th Centuries AD) and modern Murano glass pieces. As fluxes, PGAA revealed the samples are soda-lime glass, except four samples - two medieval vessel white shards and two dark Byzantine fragments of bracelets - which have potash flux. Aluminium was detected in various proportions in all samples indicating different sources for the added sand. The presence of Magnesium is relevant only in one bracelet fragment suggesting the use of plant (wood?) ash and confirming that the Byzantine bracelet is manufactured from the mixture of both types of glass (natron and plant ash based). PGAA also indicated the presence of low quantities of Cadmium, high level of Arsenic and Lead (possibly lead arsenate) in one medieval sample and of ZnO in Murano glass, and of CoO traces (maximum 0.1%) in all blue-colored Byzantine, late medieval to modern Murano glass artefacts. PIXE confirmed the use of small quantities of CoO for blue color, indicated Manganese combined with Iron for dark glass, Copper for green, Lead, Tin and an Arsenic compound (orpiment?) for yellow and in the case of modern Murano glass Selenium and Cadmium to obtain a reddish color. Despite PIXE - PIGE combination is probably the best one for glass analysis, our external milli-PIXE - PGAA methods proved to be adequate complementary tools to determine many chemical elements from glass composition - Si, Na, K, Ca, Al, Mg, various metallic oxides.

  5. A novel preconcentration technique for the PIXE analysis of water

    International Nuclear Information System (INIS)

    Savage, J.M.; Fernandez, R.F.; Zhang, W.; Robertson, J.D.; Majidi, V.

    1995-01-01

    The potential of using dried algae as a novel preconcentration technique for the analysis of water samples by PIXE was examined. The algae cells were found to contain significant levels of P and S, indicative of phosphorous- and sulfur-containing groups on the cell wall or inside the algae cells which may serve as potential binding sites for metal ions. When C. vulgaris was used on mixed metal solutions, linear responses were observed for Ag + , Ba 2+ , and Cd 2+ in the concentration range from 10 ng/g to 1 μg/g; for Cu 2+ and Pb 2+ from 10 ng/g to 5 μg/g; and for Hg 2+ from 10 ng/g to 10 μg/g. When S. bacillaris was used, linear responses were observed from 10 ng/g up to 10 μg/g for all of the metal cations investigated. The PIXE results demonstrated that metal binding at low concentrations involves replacement of sodium on the cell wall and that at high concentrations magnesium was also replaced. Competitive binding studies indicate that the metal ions, Ag + , Ba 2+ , Cd 2+ , Cu 2+ , and Pb 2+ , share common binding sites with binding efficiencies varying in the sequence of Pb 2+ >Cu 2+ >Ag 2+ >Cd 2+ >Ba 2+ . The binding of Hg 2+ involved a different binding site with an increase in binding efficiency in the presence of Ag + . (orig.)

  6. Progressive results from the PIXE program for sourcing prehistoric Papuan pottery

    International Nuclear Information System (INIS)

    Allen, J.; Duerden, P.

    1982-01-01

    A study with the aim of identifying pottery from Motupore Island, Papua New Guinea, in other local and distant sites is described. PIXE, the analytical technique used, is outlined. Elements selected for sourcing studies were: major elements - Si, Al, K, Ca, Ti, Fe; trace elements - Sr, Rb. From the results so far obtained, it is apparent that the approach is providing the legitimate allocation of prehistoric sherds to source materials on the basis of their chemical composition

  7. PIXE and Moseley's law

    International Nuclear Information System (INIS)

    Huddle, James R.

    2001-01-01

    In an undergraduate atomic physics experiment, 2.8 MeV protons are used to bombard thick elemental targets. X rays emitted from the targets are detected with a Si(Li) detector, and their energies are measured with a multichannel analyzer. The Kα and Kβ x-ray energies are each plotted as functions of (Z-1) 2 , and the Rydberg energy, Rch, is extracted from the slopes of the resulting lines. The Kα plot gives Rch=14.099±0.025 eV, while the Kβ plot gives 13.557±0.027 eV. The experiment extends the Bohr Theory as discussed in class, serves to introduce PIXE as a quantitative technique for elemental analysis, gives the students experience in using modern instruments which may be used in later experiments, and experience in using uncertainty analysis to decide whether their measurements agree or disagree with other measurements or theoretical calculations. Although the experimental values differ from each other and from the accurately-known value of 13.606 eV by less than 4%, they do not agree to within the experimental uncertainties, forcing students to consider a systematic error arising from their use of the Bohr Theory to derive Moseley's Law

  8. Element analysis on Japanese ancient glass by PIXE method

    International Nuclear Information System (INIS)

    Koizumi, Y.; Kobayashi, K.

    2001-01-01

    The authors analyzed ancient glasses using PIXE (particle induced X-ray emission) method associated with the accelerator used for the trace analysis of environments and organisms. They examined whether the material properties of the glasses made by ancient technology have correlation with those of each era or each region both in and out of Japan. The alkali lime glasses excavated from Japanese ancient ruins are classified as soda lime glasses and potash lime glasses, and intermediate glasses containing both are also detected. As for the glasses between the late Yayoi period and the early Tumulus period in eastern Japan, glass beads were mostly classified as potash lime glasses. In the mid and late Tumulus periods, soda lime glasses and the glasses with an intermediate composition increased in addition to potash lime glasses. In the analysis of the glass beads excavated from the ruins of the late Yayoi period to the early Tumult period in Tsushima, potash lime glasses and soda lime glasses coexisted in the same period. Most of the coloring components of deep-blue system mostly found in eastern Japan were manganese and iron, and the coloring components such as blue, green, sky blue, etc. were copper. Yellow was the color expressed with lead or lead - iron. The coloring materials were common regardless of the classification of glasses based on main components. (A.O.)

  9. Metallic nano-particles in lustre glazed ceramics from the 15th century in Seville studied by PIXE and RBS

    International Nuclear Information System (INIS)

    Polvorinos del Rio, A.; Castaing, J.; Aucouturier, M.

    2006-01-01

    Lustre ceramics, found in a workshop located in Triana (Sevilla), have been analysed to determine the composition of glazes including the metallic particle layers giving rise to the lustre effect. PIXE and RBS were used for the elemental composition and the sub-surface concentration profiles, respectively. Copper and silver at the origin of the lustre are detected by PIXE. RBS gives access to the detailed distribution of the elements in the surface layers. The simulation of RBS spectra confirms the occurrence of thin layers (less than 300 nm) containing metallic silver and/or copper. The results are compared with those obtained on other types of lustre ceramics

  10. Use of micro-PIXE analysis for the identification of contaminants in the metal deposition on a CMS pitch adapter

    CERN Document Server

    Massi, M; Fedi, M E; Arilli, C; Grassi, N; Mando, P A; Migliori, A; Focardi, E

    2004-01-01

    In the silicon tracker for the Compact Muon Solenoid experiment at the forthcoming Large Hadron Collider of CERN, each silicon sensor is connected to the front-end electronics by a pitch adapter, the structure of which consists of a fan of very thin chromium strips coated with a few microns aluminium deposition, on a glass support. The absence of contaminants in the depositions is of crucial importance for the electrical and mechanical reliability of the micro-bonding connections. The PIXE set-up of the Florence external micro-beam facility appeared to be suitable to analyse the metal deposition of an adapter, on which the micro-bonds had shown mechanical and electrical problems. Our measurements pointed out a significant copper contamination of the metal deposition on the faulty adapter, while no copper was detected in another one, which showed a correct behaviour at bonding. This suggests a possible role of Cu impurities in the encountered problems during micro-bonding.

  11. PIXE and GC–MS investigation for the determination of the chemical composition of Syrian Cuminum cyminum L

    International Nuclear Information System (INIS)

    Rihawy, M.S.; Bakraji, E.H.; Odeh, A.

    2014-01-01

    The chemical composition and concentration of Syrian cumin (Cuminum cyminum L.) were investigated. The particle-induced X-ray emission (PIXE) analytical technique was used to analyze a wide range of elements from Mg to Sr. The advantages and disadvantages of the PIXE technique in plant material elemental analysis are discussed. A high level of iron was detected in the cumin samples, clarifying the possible contribution of cumin to maintaining the immune system. The contribution of the elements in cumin seeds to the dietary recommended intakes (DRI) of elements was evaluated. Additionally, GC–MS measurements were performed to determine the chemical composition of cumin essential oil. Twenty-one components were identified, and cuminaldehyde, γ-terpinene, o-cymene, limonene and β-pinene were determined to be the major constituents. A correlation between the chemical composition of cumin seeds and their use as a traditional remedy is proposed. - Highlights: • To our knowledge, there is no published studies focus on the Syrian cumin composition (neither elemental nor essential oil components) in spite of its valuable medicinal importance in the country. • This work is basically dedicated to investigate both elemental content and essential oil component of the Syrian cumin seeds. • The elemental analysis was performed using PIXE, a very powerful elemental analysis technique and the essential oil components were determined using GC–MS

  12. Regional waste treatment facilities with underground monolith disposal for all low-heat-generating nuclear wastes

    International Nuclear Information System (INIS)

    Forsberg, C.W.

    1982-01-01

    An alternative system for treatment and disposal of all ''low-heat-generating'' nuclear wastes from all sources is proposed. The system, Regional Waste Treatment Facilities with Underground Monolith Disposal (RWTF/UMD), integrates waste treatment and disposal operations into single facilities at regional sites. Untreated and/or pretreated wastes are transported from generation sites such as reactors, hospitals, and industries to regional facilities in bulk containers. Liquid wastes are also transported in bulk after being gelled for transport. The untreated and pretreated wastes are processed by incineration, crushing, and other processes at the RWTF. The processed wastes are mixed with cement. The wet concrete mixture is poured into large low-cost, manmade caverns or deep trenches. Monolith dimensions are from 15 to 25 m wide, and 20 to 60 m high and as long as required. This alternative waste system may provide higher safety margins in waste disposal at lower costs

  13. PIXE measurements of drinking water of Salt Lake, Calcutta, India

    International Nuclear Information System (INIS)

    Sudarshan, M.; Dutta, R.K.; Vijayan, V.; Chintalapudi, S.N.

    2000-01-01

    A study of the trace elemental concentration in drinking water from Salt Lake City, a residential locality in Calcutta, India, was carried out using the proton induced X-ray emission (PIXE) technique. Samples were collected from overhead tanks, where drinking water is stored for supply to all parts of this residential area. A chelating agent (NaDDTC) was used for the pre-concentration of the trace elements. A large number of elements, namely Ca, Ti, Mn, Fe, Co, Ni, Cu, Zn, As, Sr, Ba, Tl and Pb were detected and the results are discussed

  14. PIXE measurements of drinking water of Salt Lake, Calcutta, India

    Energy Technology Data Exchange (ETDEWEB)

    Sudarshan, M.; Dutta, R.K.; Vijayan, V.; Chintalapudi, S.N. E-mail: snc@gamma.iuc.res.in

    2000-08-01

    A study of the trace elemental concentration in drinking water from Salt Lake City, a residential locality in Calcutta, India, was carried out using the proton induced X-ray emission (PIXE) technique. Samples were collected from overhead tanks, where drinking water is stored for supply to all parts of this residential area. A chelating agent (NaDDTC) was used for the pre-concentration of the trace elements. A large number of elements, namely Ca, Ti, Mn, Fe, Co, Ni, Cu, Zn, As, Sr, Ba, Tl and Pb were detected and the results are discussed.

  15. PIXE analysis of fish otoliths. Application to fish stock discrimination

    International Nuclear Information System (INIS)

    Arai, Nobuaki; Sakamoto, Wataru; Tateno, Koji; Yoshida, Koji.

    1996-01-01

    PIXE was adopted to analyze trace elements in otoliths of Japanese flounder to discriminate among several local fish stocks. The otoliths were removed from samples caught at five different sea areas along with the coast of the Sea of Japan: Akita, Ishikawa, Kyoto (2 stations), and Fukuoka. Besides calcium as main component, strontium, manganese, and zinc were detected. Especially Sr concentrations were different among 4 areas except between 2 stations in Kyoto. It suggested that the fish in the 2 stations in Kyoto were the same stock differed to the others. (author)

  16. PIXE analysis using external proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Potocek, V; Potockova, J; Dzmuran, R; Sikora, J

    1985-03-01

    The possibilities were studied of the practical use of the analytical PIXE method. Calibration samples were analyzed of Cu, Cd, Hg and Pb in concentrations of 50 to 500 ..mu..g/l as well as natural samples of drinking water, pond water, human blood plasma, dry waste from ground vegetation, mushrooms, pine needles, aerosols, human hair, leaves and flowers, etc. The samples were processed using precipitation, mineralization or incineration and were trapped on a membrane filter (Synpor) or on a Tatrafan ON 15 foil. Some samples were freeze-dried and compressed into pellets. A proton beam with an intensity of 10 to 70 nA was used for analysis and the proton energy was selected 2.2 MeV. For most targets an exposure of 120 s was preset and the measurement lasted at least 60 s and 600 s at the most. It was found that Synpor filters browned and became more brittle during longer exposures. The other targets did not change during analysis.

  17. Proton Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrometry (AAS) applied in the environmental sample analysis

    International Nuclear Information System (INIS)

    Popescu, Ion V.; Iordan, M.; Stihi, C.; Bancuta, A.; Dima, G.; Busuioc, G.; Ciupina, V.; Belc, M.; Badica, T.

    2003-01-01

    The aim of this work is to determine the elemental composition of tree leaves using Proton-Induced X-Rays Emission (PIXE) and Atomic Absorption Spectrophotometry (AAS) methods. By PIXE Spectrometry we identified and determined the concentration of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu Zn, As, Br, Sr and by AAS method the concentration of elements: Cr, Mn, Fe, Co, Cu, Zn, Se, Cd. Pb was identified in only 2 samples from 29. For tree leave samples collected at a large distance to the polluting source the Sr concentration decreased and the Mg, Ca, Se, Zn and Fe concentrations increased. Also, we can observe a small affinity of these leaves for the environmental Pb which was detected for two samples at a small distance to polluting source. (authors)

  18. Transfer characterization of sulfur from coal-burning emission to plant leaves by PIXE and XANES

    Energy Technology Data Exchange (ETDEWEB)

    Bao, L.M.; Zhang, G.L.; Zhang, Y.X.; Li, Y.; Lin, J.; Liu, W.; Cao, Q.C.; Zhao, Y.D.; Ma, C.Y.; Han, Y. [Chinese Academy of Sciences, Shanghai (China). Shanghai Institute of Applied Physics

    2009-11-15

    The impact of coal-burning emission on sulfur in camphor leaves was investigated using Proton Induced X-ray Emission (PIXE) and synchrotron radiation technique X-ray Absorption Near-Edge Structure (XANES) spectroscopy. The PIXE results show that the sulfur concentrations in the leaves collected at the polluted site are significantly higher than those in controls. The sulfur XANES spectra show the presence of organic (disulfides, thiols, thioethers, sulfonates and sulfoxides) and inorganic sulfur (sulfates) in the leaves. The inorganic sulfur in the leaves of camphor tree polluted by coal combustion is 15% more than that of the control site. The results suggest that the long-term coal-burning pollution resulted in an enhanced content of the total sulfur and sulfate in the leaves, and the uptake of sulfur by leaves had exceeded the metabolic requirement of plants and the excess of sulfur was stored as SO{sub 4}2{sup -}. It can monitor the sulfur pollution in atmosphere.

  19. Microprobe PIXE analysis and EDX analysis on the brain of patients with Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, S. [Tokyo Univ. (Japan). Faculty of Medicine; Horino, Y.; Mokuno, Y.; Fujii, K.; Kakimi, S.; Mizutani, T.; Matsushima, H.; Ishikawa, A.

    1996-12-31

    To investigate the cause of Alzheimer`s disease (senile dementia of Alzheimer`s disease type), we examined aluminium (Al) in the brain (hippocampus) of patients with Alzheimer`s disease using heavy ion (5 MeV Si{sup 3+}) microprobe particle-induced X-ray emission (PIXE) analysis. Heavy ion microprobes (3 MeV Si{sup 2+}) have several times higher sensitivity for Al detection than 2 MeV proton microprobes. We also examined Al in the brain of these patients by energy dispersive X-ray spectroscopy (EDX). (1) Al was detected in the cell nuclei isolated from the brain of patients with Alzheimer`s disease using 5 MeV Si{sup 3+} microprobe PIXE analysis, and EDX analysis. (2) EDX analysis demonstrated high levels of Al in the nucleolus of nerve cells in frozen sections prepared from the brain of these patients. Our results support the theory that Alzheimer`s disease is caused by accumulation of Al in the nuclei of brain cells. (author)

  20. Commercial regional incinerator facility for treatment of low-level radioactive waste

    International Nuclear Information System (INIS)

    Sauer, R.E.

    1984-01-01

    In 1981, US Ecology, Inc. began studies on the feasibility of constructing and operating a regional radioactive waste incinerator facility. In December, 1982, US Ecology requested turnkey quotations from several vendors for engineering, procurement, and construction of the new facility. After technical and commercial evaluations, a contract was awarded to Associated Technologies, Inc., of Charlotte, North Carolina, in June, 1983. In June, 1984, US Ecology made a public announcement that they were studying two sites in North Carolina for location of the facility. This same month, they submitted their permit application for a radioactive material license to the North Carolina Department of Human Resources. The facility will accept wastes from power reactors, medical and research institutions and other industrial users, and will incinerate dry solid waste, pathological waste, scintillation fluids, and turbine oils. The incinerator will be a dual chamber controlled air design, rated at 600 lbs/hr, with a venturi scrubber, packed column, HEPA, and charcoal filters for pollution control. The stack will have a continuous monitor