WorldWideScience

Sample records for refuse fired energy

  1. Marketing of fuels - energy from refuse

    Energy Technology Data Exchange (ETDEWEB)

    Tweedale, A W

    1986-03-01

    Ways of utilising low grade materials, achieving market acceptance and proving their technical and financial viability are discussed. Alternative ways in which wastes can be used to produce energy are outlined covering the incineration process whereby heat normally lost in the waste gases after the combustion of waste materials is recovered to produce heat and sometimes electricity, waste shredding and use in fluidised bed boilers, and combustion of waste pellets. Employment of utilities company and innovative and energetic approach to marketing are considered.

  2. Energy from refuse by bioconversion, fermentation and residue disposal processes

    Energy Technology Data Exchange (ETDEWEB)

    Pfeffer, J T; Liebman, J C

    1976-01-01

    Bioconversion of organic refuse to CH/sub 4/ by anaerobic fermentation is 1 mechanism by which the energy in urban waste can be reclaimed. Laboratory studies were made to determine the rate and amount of gas production at various operating temperatures. The dewatering characteristics of the spent fermentation slurry were evaluated. The spent solids can be dewatered to a sufficiently low moisture content such that incineration is self-sustaining. The incineration system was evaluated to determine the possible energy recovery from the spent cake. A process for treating the liquid blowdown from the system was developed. A mathematical simulation of the total system was constructed to evaluate performance under various operating conditions. A plant processing 908 tons of refuse/day will produce 3905 m/sup 3/ CH/sub 4//hr. Recovery of just CH/sub 4/ provides a 32.6% efficiency of energy recovery. This efficiency can be increased to 63.4% if steam from the incinerator can be sold.

  3. System for manufacturing ash products and energy from refuse waste

    Energy Technology Data Exchange (ETDEWEB)

    Sutin, G.L.; Mahoney, P.F.

    1996-01-04

    The present invention provides a system of manufacturing energy and ash products from solid waste. The system includes apparatus for receiving solid waste for processing, apparatus for shredding the received solid waste, apparatus for removing ferrous material from the shredded solid waste to create processed refuse fuel (PRF) and apparatus for efficiently combusting the PRF. A conveyor transfers the PRF to the combusting apparatus such that the density of the PRF is always controlled for continuous non-problematic flow. Apparatus for recovering residual combustion particulate from the combustion residual gases and for recovering solid ash residue provides the system with the ability to generate steam and electrical energy, and to recover for reuse and recycling valuable materials from the solid ash residue. (author) figs.

  4. Research report. Environmentally friendly energy community research business for Fujieda district (Refuse energy utilization); Fujieda chiku kankyo chowagata energy community chosa jigyo (haikibutsu energy riyo shisetsu) chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    An environmentally friendly refuse energy utilizing business, for which RDF (refuse derived fuel) produced out of wastes discharged by industries belonging to a Fujieda city environmental protection council will provide the heat source, is proposed by the said council. The proposal is subjected to a study, a basic plan is drafted, and a decision is made on its profitability. In the study, surveys are conducted on the actualities of wastes and of demand for heat, and specifications are worked out relating to transportation and storage of RDF, production of steam by an RDF-fired boiler, routing of pipes for transmitting the steam to the industries in the district, facility costs, operating costs, etc. It is found that the amount of RDF produced out of the wastes discharged by the council member industries is so small that it can meet the demand of only one industry and that, even if more wastes are collected from a wider area, the increased amount will but meet the demand of two industries and a hot water pool. It is found that the system will be economically feasible, however, if the shortage of RDF-generated energy is covered by an oil-fired boiler and thereby impartiality is established in steam distribution and steam production unit price is reduced. In view of the intensification of control over dioxin, etc., the business will be gaining profit in 2002 and after. (NEDO)

  5. Environment-friendly type energy and coordinated community development project. Feasibility study for industrialization of high efficiency waste-fired power generation system (industrial refuse derived fuel and gas turbine combined type); Kankyo chowagata energy community keisei sokushin. Kokoritsu haikibutsu hatsuden (sangyo RDF GT fukugogata) jigyoka FS chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    High efficiency power generation, which is useful for promoting the environment-friendly type energy and coordinated community, is investigated by combining a steam turbine power generation system using the PS-RDF (paper sludge-refuse derived fuel) and a gas turbine (GT) combined cycle. Industrialization plan for processing PS in low cost has been made to ensure the profitability by participating the wholesale power supply under the law of electric power industry. This combined system is similar to the so-called super power generation using municipal garbage, but the lower temperature of steam from GT waste heat boilers (WHB) is super-heated by the flue gas from RDF boiler, which is called advanced power generation system (A.S.S.). The total power generation capacity is 149,000 kW, which consists of three 35,000 kW units of GT and one 44,000 kW unit of steam turbine. When comparing the combined system (A.S.S.) and usual one with the independent installation of the RDF steam power generation system and a GT combined cycle, the A.S.S. provides the repowering efficiency of 7,600 kW output with exactly the same quantity of fuel input as usual one. 71 figs., 31 tabs.

  6. Energy efficacy used to score organic refuse pretreatment processes for hydrogen anaerobic production.

    Science.gov (United States)

    Ruggeri, Bernardo; Luongo Malave, Andrea C; Bernardi, Milena; Fino, Debora

    2013-11-01

    The production of hydrogen through Anaerobic Digestion (AD) has been investigated to verify the efficacy of several pretreatment processes. Three types of waste with different carbon structures have been tested to obtain an extensive representation of the behavior of the materials present in Organic Waste (OW). The following types of waste were selected: Sweet Product Residue (SPR), i.e., confectionary residue removed from the market after the expiration date, Organic Waste Market (OWM) refuse from a local fruit and vegetable market, and Coffee Seed Skin (CSS) waste from a coffee production plant. Several pretreatment processes have been applied, including physical, chemical, thermal, and ultrasonic processes and a combination of these processes. Two methods have been used for the SPR to remove the packaging, manual (SPR) and mechanical (SPRex). A pilot plant that is able to extrude the refuse to 200atm was utilized. Two parameters have been used to score the different pretreatment processes: efficiency (ξ), which takes into account the amount of energy produced in the form of hydrogen compared with the available energy embedded in the refuse, and efficacy (η), which compares the efficiency obtained using the pretreated refuse with that obtained using the untreated refuse. The best result obtained for the SPR was the basic pretreatment, with η=6.4, whereas the thermal basic pretreatment gave the highest value, η=17.0 for SPRex. The best result for the OWM was obtained through a combination of basic/thermal pretreatments with η=9.9; lastly, the CSS residue with ultrasonic pretreatment produced the highest quantity of hydrogen, η=5.2. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. The European investment bank and financing the installation of urban refuse treatment plants with energy recovery

    International Nuclear Information System (INIS)

    Marty-Gauquie, H.

    1992-01-01

    The European Investment Bank (BEI), the world's leading international financing institution, with an annual loans total of 15.3 billion Ecus in 1991, every year finances a number of projects for the treatment of refuse, with energy recovery from waste and heat distribution. This article describes the missions of the BEI and the parameters taken into account for authorizing investment. (author). 2 figs., 2 tabs

  8. Fire hazard analysis for fusion energy experiments

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1979-01-01

    The 2XIIB mirror fusion facility at Lawrence Livermore Laboratory (LLL) was used to evaluate the fire safety of state-of-the-art fusion energy experiments. The primary objective of this evaluation was to ensure the parallel development of fire safety and fusion energy technology. Through fault-tree analysis, we obtained a detailed engineering description of the 2XIIB fire protection system. This information helped us establish an optimum level of fire protection for experimental fusion energy facilities as well as evaluate the level of protection provided by various systems. Concurrently, we analyzed the fire hazard inherent to the facility using techniques that relate the probability of ignition to the flame spread and heat-release potential of construction materials, electrical and thermal insulations, and dielectric fluids. A comparison of the results of both analyses revealed that the existing fire protection system should be modified to accommodate the range of fire hazards inherent to the 2XIIB facility

  9. Moderate Image Spectrometer (MODIS) Fire Radiative Energy: Physics and Applications

    Science.gov (United States)

    Kaufman, Y.

    2004-01-01

    MODIS fire channel does not saturate in the presence of fires. The fire channel therefore is used to estimate the fire radiative energy, a measure of the rate of biomass consumption in the fire. We found correlation between the fire radiative energy, the rate of formation of burn scars and the rate of emission of aerosol from the fires. Others found correlations between the fire radiative energy and the rate of biomass consumption. This relationships can be used to estimates the emissions from the fires and to estimate the fire hazards.

  10. Refuse-derived fuel as a secondary energy in Taiwan - Using Hotelling space allocation model

    International Nuclear Information System (INIS)

    Kwodong Wey; Sheueching Hong

    2006-01-01

    Most Taiwanese farmers usually blend rice straws into the soil after harvest. However, rice straws possess great thermal energy, which can be used to produce refuse-derived fuel (RDF-5). As Taiwan faces energy shortage, the development benefits of the RDF-5 industry are tempting. This study employs the Hotelling model to design the locations and the optimal numbers of RDF-5 plants. From the technology and material supply point of view, turning waste rice straws into RDF-5 is feasible in Taiwan. Nevertheless, from the business operation perspective, even if the RDF-5 plant is willing to lower its profit rate, its selling price is still hard to compete with imported RDF-5. If the Taiwanese government decides to pursue RDF-5 as an alternative energy, they might need to take a step further to subsidize entrepreneurs or provide appropriate tax benefits. Otherwise, the RDF-5 industry is hard to survive in Taiwan. (Author)

  11. Energy recovery from municipal solid waste by refuse derived fuel production in Malaysia

    International Nuclear Information System (INIS)

    Sanaz Saheri; Noorezlin Ahmad Baseri; Masoud Aghajani Mir; Malmasi Saeed

    2010-01-01

    Energy recovery from municipal solid waste (MSW) is so beneficial both for the energy and for the positive environmental implications. Mainly related to the saving of primary energy derived from fossil fuel. Malaysia as a fast growing population country has the average amount of municipal solid waste (MSW) generated around 0.5-0.8 kg/person/day and it has been increased to 1.7 kg/person/day in major cities. Regarding characterization exercise, the main parts of the Malaysian MSW were found to be food, paper and plastic, which made up almost 80 % of the waste by weight. Furthermore, the average moisture content of the MSW was about 55 %, making incineration a challenging mission. In addition waste sectors in Malaysia contributes to 1.3 million ton of CH 4 compare to total CH 4 emission which is 2.2 MT. In order to overcome waste problem considering other technical, environmental and economical methods seems to be necessarily. Resource recovery centers recovers the maximum proportion of recyclable and recoverable resources from the mixed municipal solid waste .The resource recovery process itself is one of the step-by-step segregation and elimination of all non-combustibles , and separation of the combustibles in the desired form of fuel for good combustion. Then, a further mechanical separation process converts combustible materials to refuse derived fuel (RDF) with moisture content between 20 and 30 % and an average calorific fuel value of about 3450 kcal/kg. So, the aim of this paper is taking into account resource recovery from waste using refuse derived fuel as a secondary resource with regarding advantages and disadvantages of this kind of energy production in Malaysia as a developing country. (author)

  12. New fire diurnal cycle characterizations to improve fire radiative energy assessments made from MODIS observations

    NARCIS (Netherlands)

    Andela, N.; Kaiser, J.; van der Werf, G.R.

    2015-01-01

    Accurate near real time fire emissions estimates are required for air quality forecasts. To date, most approaches are based on satellite-derived estimates of fire radiative power (FRP), which can be converted to fire radiative energy (FRE) which is directly related to fire emissions. Uncertainties

  13. Health and environmental effects of refuse derived fuel (RDF) production and RDF/coal co-firing technologies

    Energy Technology Data Exchange (ETDEWEB)

    O' Toole, J.J.; Wessels, T.E.; Lynch, J.F.; Fassel, V.A.; Lembke, L.L.; Kniseley, R.N.; Norton, G.A.; Junk, G.A.; Richard, J.J.; Dekalb, E.L.; Dobosy, R.J.

    1981-10-01

    Six facilities, representing the scope of different co-firing techniques with their associated RDF production systems were reviewed in detail for combustion equipment, firing modes, emission control systems, residue handling/disposal, and effluent wastewater treatment. These facilities encompass all currently operational or soon to be operational co-firing plants and associated RDF production systems. Occupational health and safety risks for these plants were evaluated on the basis of fatal and nonfatal accidents and disease arising from the respective fuel cycles, coal and RDF. Occupational risks include exposure to pathogenic organisms in the workplace. Unusual events that are life threatening in the RDF processing industry (e.g., explosions) are also discussed and remedial and safety measures reviewed. 80 refs., 4 figs., 30 tabs.

  14. Fire analog: a comparison between fire plumes and energy center cooling tower plumes

    Energy Technology Data Exchange (ETDEWEB)

    Orgill, M.M.

    1977-10-01

    Thermal plumes or convection columns associated with large fires are compared to thermal plumes from cooling towers and proposed energy centers to evaluate the fire analog concept. Energy release rates of mass fires are generally larger than for single or small groups of cooling towers but are comparable to proposed large energy centers. However, significant physical differences exist between cooling tower plumes and fire plumes. Cooling tower plumes are generally dominated by ambient wind, stability and turbulence conditions. Fire plumes, depending on burning rates and other factors, can transform into convective columns which may cause the fire behavior to become more violent. This transformation can cause strong inflow winds and updrafts, turbulence and concentrated vortices. Intense convective columns may interact with ambient winds to create significant downwind effects such as wakes and Karman vortex streets. These characteristics have not been observed with cooling tower plumes to date. The differences in physical characteristics between cooling tower and fire plumes makes the fire analog concept very questionable even though the approximate energy requirements appear to be satisfied in case of large energy centers. Additional research is suggested in studying the upper-level plume characteristics of small experimental fires so this information can be correlated with similar data from cooling towers. Numerical simulation of fires and proposed multiple cooling tower systems could also provide comparative data.

  15. School Refusal

    Science.gov (United States)

    Wimmer, Mary

    2008-01-01

    School attendance is an ongoing concern for administrators, particularly in middle level and high school. Frequent absences affect student learning, test scores, and social development. Absenteeism is often the result of emotional disorders, such as anxiety or depression. Administrators who understand the causes of school refusal behavior and are…

  16. Energy poverty, shack fires and childhood burns

    African Journals Online (AJOL)

    sufficient choice in accessing adequate, affordable, reliable, high- quality, safe and ... The impact of informal settlement shack fires on individuals and communities has ... often the loss of lives. Fires kill thousands of people every year, with many more disabled .... self-extinguishing mechanism, which ensures that the flame is ...

  17. Early forest fire detection using low-energy hydrogen sensors

    Directory of Open Access Journals (Sweden)

    K. Nörthemann

    2013-11-01

    Full Text Available Most huge forest fires start in partial combustion. In the beginning of a smouldering fire, emission of hydrogen in low concentration occurs. Therefore, hydrogen can be used to detect forest fires before open flames are visible and high temperatures are generated. We have developed a hydrogen sensor comprising of a metal/solid electrolyte/insulator/semiconductor (MEIS structure which allows an economical production. Due to the low energy consumption, an autarkic working unit in the forest was established. In this contribution, first experiments are shown demonstrating the possibility to detect forest fires at a very early stage using the hydrogen sensor.

  18. Co-firing a pressurized fluidized-bed combustion system with coal and refuse derived fuels and/or sludges. Task 16

    Energy Technology Data Exchange (ETDEWEB)

    DeLallo, M.; Zaharchuk, R.

    1994-01-01

    The co-firing of waste materials with coal in utility scale power plants has emerged as an effective approach to produce energy and manage municipal waste. Leading this approach, the atmospheric fluidized-bed combustor (AFBC) has demonstrated its commercial acceptance in the utility market as a reliable source of power burning a variety of waste and alternative fuels. The fluidized bed, with its stability of combustion, reduces the amount of thermochemical transients and provides for easier process control. The application of pressurized fluidized-bed combustor (PFBC) technology, although relatively new, can provide significant enhancements to the efficient production of electricity while maintaining the waste management benefits of AFBC. A study was undertaken to investigate the technical and economic feasibility of co-firing a PFBC with coal and municipal and industrial wastes. Focus was placed on the production of electricity and the efficient disposal of wastes for application in central power station and distributed locations. Wastes considered for co-firing include municipal solid waste (MSW), tire-derived fuel (TDF), sewage sludge, and industrial de-inking sludge. Issues concerning waste material preparation and feed, PFBC operation, plant emissions, and regulations are addressed. This paper describes the results of this investigation, presents conclusions on the key issues, and provides recommendations for further evaluation.

  19. Measurements relating fire radiative energy density and surface fuel consumption - RxCADRE 2011 and 2012

    Science.gov (United States)

    Andrew T. Hudak; Matthew B. Dickinson; Benjamin C. Bright; Robert L. Kremens; E. Louise Loudermilk; Joseph J. O' Brien; Benjamin S. Hornsby; Roger D. Ottmar

    2016-01-01

    Small-scale experiments have demonstrated that fire radiative energy is linearly related to fuel combusted but such a relationship has not been shown at the landscape level of prescribed fires. This paper presents field and remotely sensed measures of pre-fire fuel loads, consumption, fire radiative energy density (FRED) and fire radiative power flux density (FRFD),...

  20. Combustion tests in a solid fuel boiler to clarify the emissions when co-firing refuse; Proveldning i fastbraenslepanna foer att kartlaegga emissioner vid inblandning av olika avfallsfraktioner

    Energy Technology Data Exchange (ETDEWEB)

    Blom, Elisabet; Lundborg, Rickard; Wrangensten, Lars

    2002-04-01

    In this Vaermeforsk-project tests have been performed in a 60 MW moving grate steam boiler at Tekniska Verken in Linkoeping. The boiler plant has an electrostatic filter for dust reduction and also a flue gas condensing plant with heat recovery. Vaermeforsk has financed the project. During the tests the following fuel fractions have been injected into the reference fuel, a mix of recovered wood chips (70 %) and bark (30 %): Paper/plastic/wood fuel (10 % and 25 % injection on an energy basis); Meat powder (10 % and 25 % injection on an energy basis); Napkin waste (10 % injection on an energy basis); Leather waste (10 % injection on an energy basis). The highest lower heating value was noted for meat powder, approx. 24 MJ/kg with a moisture content of 3,4 %. The heating values for the other fuel fractions were on the same level or just beneath the corresponding heating value for the reference fuel. The highest chlorine content was found in the paper/plastic/wood fraction respectively the leather waste fraction with 1,2 and 1,4 % (weight) of chlorine. The meat powder had the highest nitrogen content but all the fuel mixes had a quite high content of nitrogen with values over 1 % (weight). Analyses of sulphur in the fuels showed that leather waste had the lowest content just over 0, 1 %, considered as a low sulphur level for fuels in general. However, there are problems to get balance between in- and output for sulphur and chlorine based on fuel analysis. Difficulties to take representative fuel samples, especially when it comes to chlorine, can be an explanation. Video camera recordings and flue gas analysis in the furnace showed that the injection of refuse fractions seems to improve the combustion conditions with better local combustion of CO and hydrocarbons. The results from the emission measurements in the chimney can be summarised as follows (emission values at 11 % O{sub 2}): the lowest CO emission was noted with 25 % meat powder injection (<50 mg/nm{sup 3

  1. Assessment of fire hazards in buildings housing fusion energy experiments

    International Nuclear Information System (INIS)

    Alvares, N.; Lipska, A.

    1978-01-01

    A number of materials in and within the proximity of buildings housing fusion energy experiments (FEE) were analyzed for their potential fire hazard. The materials used in this study were mostly: electrical and thermal insulations. The fire hazard of these materials was assessed in terms of their ease of ignition, heat release rate, generation of smoke, and the effect of thermal environment on the combustion behavior. Several fire protection measures for buildings housing the (FEE) projects are analyzed and as a result of this study are found to be adequate for the near term

  2. Results of combustion and emissions testing when co-firing blends of binder-enhanced densified refuse-derived fuel (b-dRDF) pellets and coal in a 440 MW{sub e} cyclone fired combustor. Volume 3: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Ohlsson, O.

    1994-07-01

    This report contains the data resulting from the co-firing of b-dRDF pellets and coal in a 440-MW{sub e} cyclone-fired combustor. These tests were conducted under a Collaborative Research and Development Agreement (CRADA). The CRADA partners included the U.S. Department of Energy (DOE), National Renewable Energy Laboratory (NREL), Argonne National Laboratory (ANL), Otter Tail Power Company, Green Isle Environmental, Inc., XL Recycling Corporation, and Marblehead Lime Company. The report is made up of three volumes. This volume contains other supporting information, along with quality assurance documentation and safety and test plans. With this multi-volume approach, readers can find information at the desired level of detail, depending on individual interest or need.

  3. Gas-Fired Distributed Energy Resource Technology Characterizations

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, L.; Hedman, B.; Knowles, D.; Freedman, S. I.; Woods, R.; Schweizer, T.

    2003-11-01

    The U. S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) is directing substantial programs in the development and encouragement of new energy technologies. Among them are renewable energy and distributed energy resource technologies. As part of its ongoing effort to document the status and potential of these technologies, DOE EERE directed the National Renewable Energy Laboratory to lead an effort to develop and publish Distributed Energy Technology Characterizations (TCs) that would provide both the department and energy community with a consistent and objective set of cost and performance data in prospective electric-power generation applications in the United States. Toward that goal, DOE/EERE - joined by the Electric Power Research Institute (EPRI) - published the Renewable Energy Technology Characterizations in December 1997.As a follow-up, DOE EERE - joined by the Gas Research Institute - is now publishing this document, Gas-Fired Distributed Energy Resource Technology Characterizations.

  4. Laboratory investigation of fire radiative energy and smoke aerosol emissions

    Science.gov (United States)

    Charles Ichoku; J. Vanderlei Martins; Yoram J. Kaufman; Martin J. Wooster; Patrick H. Freeborn; Wei Min Hao; Stephen Baker; Cecily A. Ryan; Bryce L. Nordgren

    2008-01-01

    Fuel biomass samples from southern Africa and the United States were burned in a laboratory combustion chamber while measuring the biomass consumption rate, the fire radiative energy (FRE) release rate (Rfre), and the smoke concentrations of carbon monoxide (CO), carbon dioxide (CO2), and particulate matter (PM). The PM mass emission rate (RPM) was quantified from...

  5. Energy requirement for firing porcelain | M. de O. Madivate | Bulletin ...

    African Journals Online (AJOL)

    Results from studies on the ternary system Ribaué kaolin–Carapira feldspar– Marracuene quartz sands were used to test a procedure that we developed for calculation of the energy requirement for firing porcelain. Results obtained vary between 1300 and 1800 kJ/kg porcelain. These results differ largely from the ones ...

  6. Energy poverty, shack fires and childhood burns

    Directory of Open Access Journals (Sweden)

    D K Kimemia

    2017-04-01

    Full Text Available Burn injuries are a persisting challenge in South Africa. Energy poverty, prevalent in under-resourced communities, is a key contributor to the problem. The energy-poor rely on solid fuels and flammable hydrocarbons, such as paraffin, for energy services. The fuels are burnt in inefficient, leaky and unstable appliances, leading to health losses from pollutant emissions, burns, and conflagrations. Within cramped informal home settings, using flammable fuels and risky combustion technologies, the situation can become devastating, especially for young children. Those who survive fiery incidents have to contend with trauma and property losses that may lead to further impoverishment. Proactive intervention strategies are required and should include the broadening of access to safe and sustainable energy. We advocate greater enforcement of home appliance standards and targeted support for the distribution of proven alternative energy technologies, such as liquefied petroleum gas and solar power. Support and advocacy from professional and citizen groups would be necessary to ensure that government prioritises the safe energy requirements of poor citizens.

  7. Effect of fuel type and deposition surface temperature on the growth and structure of ash deposit collected during co-firing of coal with sewage-sludge, saw-dust and refuse derived fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kupka, Tomasz; Zajac, Krzysztof; Weber, Roman [Clausthal Univ. of Technology, Clausthal-Zellerfeld (Germany). Inst. of Energy Process Engineering and Fuel Technology

    2008-07-01

    Blends of a South African bituminous ''Middleburg'' coal and three alternative fuels (a municipal sewage-sludge, a saw-dust and a refuse derived fuel) have been fired in the slagging reactor to examine the effect of the added fuel on slagging propensity of the mixtures. Two kinds of deposition probes have been used, un-cooled ceramic probes and air-cooled steal probes. Distinct differences in physical and chemical structures of the deposits collected using the un-cooled ceramic probes and air-cooled metal probes have been observed. Glassy, easily molten deposits collected on un-cooled ceramic deposition probes were characteristic for co-firing of municipal sewage-sludge with coal. Porous, sintered (not molten) but easily removable deposits of the same fuel blend have been collected on the air-cooled metal deposition probes. Loose, easy removable deposits have been sampled on air-cooled metal deposition probe during co-firing of coal/saw-dust blends. The mass of the deposit sampled at lower surface temperatures (550-700 C) was always larger than the mass sampled at higher temperatures (1100-1300 C) since the higher temperature ash agglomerated and sintered much faster than the low temperature deposit. (orig.)

  8. Energy economics of nuclear and coal fired power plant

    International Nuclear Information System (INIS)

    Lee, Kee Won; Cho, Joo Hyun; Kim, Sung Rae; Choi, Hae Yoon

    1995-01-01

    The upturn of Korean nuclear power program can be considered to have started in early 70's while future plants for the construction of new nuclear power plants virtually came to a halt in United States. It is projected that power plant systems from combination of nuclear and coal fired types might shift to all coal fired type, considering the current trend of construction on the new plants in the United States. However, with the depletion of natural resources, it is desirable to understand the utilization of two competitive utility technologies in terms of of invested energy. Presented in this paper is a comparison between two systems, nuclear power plant and coal fired steam power plant in terms of energy investment. The method of comparison is Net Energy Analysis (NEA). In doing so, Input-Output Analysis (IOA) among industries and commodities is done. Using these information, net energy ratios are calculated and compared. NEA is conducted for power plants in U.S. because the availability of necessary data are limited in Korea. Although NEA does not offer conclusive solution, this method can work as a screening process in decision making. When considering energy systems, results from such analysis can be used as a general guideline. 2 figs., 12 tabs., 5 refs. (Author)

  9. Use of ordinary kriging and Gaussian conditional simulation to interpolate airborne fire radiative energy density estimates

    Science.gov (United States)

    C. Klauberg; A. T. Hudak; B. C. Bright; L. Boschetti; M. B. Dickinson; R. L. Kremens; C. A. Silva

    2018-01-01

    Fire radiative energy density (FRED, J m-2) integrated from fire radiative power density (FRPD, W m-2) observations of landscape-level fires can present an undersampling problem when collected from fixed-wing aircraft. In the present study, the aircraft made multiple passes over the fire at ~3 min intervals, thus failing to observe most of the FRPD emitted as the flame...

  10. Early Forest Fire Detection Using Low Energy Hydrogen Sensors

    Directory of Open Access Journals (Sweden)

    Jürgen Müller

    2016-08-01

    Full Text Available The North-east German Lowlands is a region with one of the highest forest fire risks in Europe. In order to keep damage levels as low as possible, it is important to have an effective early warning system. Such a system is being developed on the basis of a hydrogen sensor, which makes it possible to detect a smouldering forest fire before the development of open flames. The prototype hydrogen sensor produced at the Humboldt University Berlin has a metal/ solid electrolyte/insulator/ semiconductor (MEIS structure, which allows cost-effective production. Due to the low energy consumption, an autarchic working unit could be installed in the forest. Field trials have shown that it is possible to identify a forest fire in its early stages when hydrogen concentrations are still low. A significant change in the signal due to a fire was measured at a distance of about 100m. In view of the potential impacts of climate change, the innovative pre-ignition warning system is an important early diagnosis and monitoring module for the protection of the forests.

  11. FIRE

    International Nuclear Information System (INIS)

    Brtis, J.S.; Hausheer, T.G.

    1990-01-01

    FIRE, a microcomputer based program to assist engineers in reviewing and documenting the fire protection impact of design changes has been developed. Acting as an electronic consultant, FIRE is designed to work with an experienced nuclear system engineer, who may not have any detailed fire protection expertise. FIRE helps the engineer to decide if a modification might adversely affect the fire protection design of the station. Since its first development, FIRE has been customized to reflect the fire protection philosophy of the Commonwealth Edison Company. That program is in early production use. This paper discusses the FIRE program in light of its being a useful application of expert system technologies in the power industry

  12. Process for producing a fuel suitable for degassing from refuse

    Energy Technology Data Exchange (ETDEWEB)

    Sulzberger, J

    1975-11-20

    Utilization of the heat energy of refuse in waste incineration plants is time-consuming and expensive due to high investment and operation costs. The inventor recommends to process the refuse to a sterile, handy and storable fuel. For this propose the refuse should be crushed, kneaded and pressed. The briquettes produced in this way should be dried.

  13. 20000G shock energy harvesters for gun-fired munition

    International Nuclear Information System (INIS)

    Willemin, J.; Boisseau, S.; Olmos, L.; Gallardo, M.; Despesse, G.; Robert, T.

    2016-01-01

    This paper presents a 20000G shock energy harvester dedicated to gun-fired munitions and based on a mass-spring resonant structure coupled to a coil-magnet electromagnetic converter. The 20000G shock energy is firstly stored in the spring as elastic potential energy, released as mass-spring mechanical oscillations right after the shock and finally converted into electricity thanks to the coil-magnet transducer. The device has been modeled, sized to generate 200mJ in 150ms, manufactured and tested in a gun-fired munition. The prototype sizes 117cm 3 and weighs 370g. 210mJ have been generated in a test bench and 140mJ in real conditions; this corresponds to a mean output power of 0.93W (7.9mW/cm 3 ) and a maximum output power of 4.83W (41.3mW/cm 3 ) right after the shock. (paper)

  14. 20000G shock energy harvesters for gun-fired munition

    Science.gov (United States)

    Willemin, J.; Boisseau, S.; Olmos, L.; Gallardo, M.; Despesse, G.; Robert, T.

    2016-11-01

    This paper presents a 20000G shock energy harvester dedicated to gun-fired munitions and based on a mass-spring resonant structure coupled to a coil-magnet electromagnetic converter. The 20000G shock energy is firstly stored in the spring as elastic potential energy, released as mass-spring mechanical oscillations right after the shock and finally converted into electricity thanks to the coil-magnet transducer. The device has been modeled, sized to generate 200mJ in 150ms, manufactured and tested in a gun-fired munition. The prototype sizes 117cm3 and weighs 370g. 210mJ have been generated in a test bench and 140mJ in real conditions; this corresponds to a mean output power of 0.93W (7.9mW/cm3) and a maximum output power of 4.83W (41.3mW/cm3) right after the shock.

  15. Groundwater controls on post-fire permafrost thaw: Water and energy balance effects

    OpenAIRE

    Rocha, Adrian; Mckenzie, Jeffrey; Lamontagne-Halle, Pierrick; Zipper, Samuel

    2018-01-01

    Fire frequency and severity is increasing in high latitude regions, with large impacts on the water and energy balances. However, the degree to which groundwater flow impacts the permafrost response to fire remains poorly understood and understudied. Here, we use the Anaktuvuk River Fire (Alaska, USA) as an archetypal example to investigate groundwater-permafrost interactions following fire. We identify key thermal and hydrologic parameters controlling permafrost and active layer response to ...

  16. Fire-Protection Research for Energy-Technology Projects: FY 1981 year-end report

    International Nuclear Information System (INIS)

    Hasegawa, H.K.; Alvares, N.J.; Lipska-Quinn, A.E.; Beason, D.G.; Foote, K.L.; Priante, S.J.

    1982-01-01

    This report summarizes research conducted in fiscal year 1981 for the DOE-supported project, Fire Protection Research for Energy Technology Projects. Initiated in 1977, this ongoing research program was conceived to advance fire protection strategies for Energy Technology Projects to keep abreast of the unique fire problems that are developing with the complexity of energy technology research. We are developing an analytical methodology through detailed study of fusion energy experiments at Lawrence Livermore National Laboratory (LLNL). Employing these facilities as models for methodology development, we are simultaneously advancing three major task areas: (1) determination of unique fire hazards of current fusion energy facilities; (2) evaluation of the ability of accepted fire management measures to meet and negate hazards; and (3) performance of unique research into problem areas we have identified to provide input into analytical fire-growth and damage-assessment models

  17. Fire-Protection Research for Energy-Technology Projects: FY 1981 year-end report

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, H.K.; Alvares, N.J.; Lipska-Quinn, A.E.; Beason, D.G.; Foote, K.L.; Priante, S.J.

    1982-07-20

    This report summarizes research conducted in fiscal year 1981 for the DOE-supported project, Fire Protection Research for Energy Technology Projects. Initiated in 1977, this ongoing research program was conceived to advance fire protection strategies for Energy Technology Projects to keep abreast of the unique fire problems that are developing with the complexity of energy technology research. We are developing an analytical methodology through detailed study of fusion energy experiments at Lawrence Livermore National Laboratory (LLNL). Employing these facilities as models for methodology development, we are simultaneously advancing three major task areas: (1) determination of unique fire hazards of current fusion energy facilities; (2) evaluation of the ability of accepted fire management measures to meet and negate hazards; and (3) performance of unique research into problem areas we have identified to provide input into analytical fire-growth and damage-assessment models.

  18. Keynote address: Reinventing fire: Physics + markets = energy solutions

    Energy Technology Data Exchange (ETDEWEB)

    Lovins, Amory B., E-mail: ablovins@rmi.org [Cofounder and Chief Scientist, Rocky Mountain Institute, 2317 Snowmass Creek Road, Snowmass CO 81654 (United States)

    2015-03-30

    Rocky Mountain Institute's multi-year, 61-author, peer-reviewed Reinventing Fire synthesis showed how the U.S. can realistically run a 2.6× bigger U.S. economy in 2050 with no oil, coal, or nuclear energy, one-third less natural gas, tripled efficiency, and 74% renewable supplies (80% for electricity). This transition, at historically reasonable rates, could be led by business for profit, applying normal rates of return, with some innovative subnational and administrative policies but no Acts of Congress. Excluding carbon emissions and all other externalities, the net present value would be $5 trillion more favorable than business-as-usual, averaging a 14% Internal Rate of Return.

  19. Keynote address: Reinventing fire: Physics + markets = energy solutions

    International Nuclear Information System (INIS)

    Lovins, Amory B.

    2015-01-01

    Rocky Mountain Institute's multi-year, 61-author, peer-reviewed Reinventing Fire synthesis showed how the U.S. can realistically run a 2.6× bigger U.S. economy in 2050 with no oil, coal, or nuclear energy, one-third less natural gas, tripled efficiency, and 74% renewable supplies (80% for electricity). This transition, at historically reasonable rates, could be led by business for profit, applying normal rates of return, with some innovative subnational and administrative policies but no Acts of Congress. Excluding carbon emissions and all other externalities, the net present value would be $5 trillion more favorable than business-as-usual, averaging a 14% Internal Rate of Return

  20. Coal refuse reclamation project

    Energy Technology Data Exchange (ETDEWEB)

    Zellmer, S.D.

    1979-04-06

    A 13.8 ha abandoned coal refuse site in southwestern Illinois was reclaimed by recontouring the refuse material and covering it with a minimum 30 cm of soil. The reclamation procedure included determination of the site's final land use, collection of preconstruction environmental data, and development and implementation of engineering plans. The project is demonstrating methods that can be used to reclaim abandoned coal refuse sites, and a multidisciplinary approach is being used to evaluate postconstruction environmental and economic effects of the reclamation effort. Surface water quality has shown significant improvement and plant cover is becoming established on the site. Soil microbial populations are developing and wildlife habitats are forming. The economic value of the site and adjacent properties has increased substantially and the area's aesthetic value has been enhanced. This project is providing valuable design data for future reclamation efforts of this type.

  1. Fire protection research for energy technology projects; FY 79 year-end report

    International Nuclear Information System (INIS)

    Hasegawa, H.K.; Alvares, N.J.; Lipska, A.E.; Ford, H.; Beason, D.G.

    1981-01-01

    This report describes work performed in fiscal year 1979, on a DOE funded study entitled Fire Protection Research for Energy Technology Projects. The primary goal of this program is to ensure that fire protection measures for Fusion Energy Experiments (FEE) evolve concurrently with the complexity of FEE. Ultimately, it is planned that the detailed study of fusion experiments will provide an analytical methodology which can be applied to the full range of energy technology projects. We attempt to achieve this objective by coordinately advancing 3 (three) major task areas; (a) determine the fire hazards of current FEE facilities (b) assess the ability of accepted fire management strategies to meet and negate the hazard, (c) perform unique research into problem areas we have identified to provide input into analytical fire growth and damage assessment models

  2. Fire-protection research for energy technology: Fy 80 year end report

    Science.gov (United States)

    Hasegawa, H. K.; Alvares, N. J.; Lipska, A. E.; Ford, H.; Priante, S.; Beason, D. G.

    1981-05-01

    This continuing research program was initiated in order to advance fire protection strategies for Fusion Energy Experiments (FEE). The program expanded to encompass other forms of energy research. Accomplishments for fiscal year 1980 were: finalization of the fault-free analysis of the Shiva fire management system; development of a second-generation, fire-growth analysis using an alternate model and new LLNL combustion dynamics data; improvements of techniques for chemical smoke aerosol analysis; development and test of a simple method to assess the corrosive potential of smoke aerosols; development of an initial aerosol dilution system; completion of primary small-scale tests for measurements of the dynamics of cable fires; finalization of primary survey format for non-LLNL energy technology facilities; and studies of fire dynamics and aerosol production from electrical insulation and computer tape cassettes.

  3. Fire-protection research for energy technology: FY 80 year-end report

    International Nuclear Information System (INIS)

    Hasegawa, H.K.; Alvares, N.J.; Lipska, A.E.; Ford, H.; Priante, S.; Beason, D.G.

    1981-01-01

    This continuing research program was initiated in 1977 in order to advance fire protection strategies for Fusion Energy Experiments (FEE). The program has since been expanded to encompass other forms of energy research. Accomplishments for fiscal year 1980 were: finalization of the fault-tree analysis of the Shiva fire management system; development of a second-generation, fire-growth analysis using an alternate moel and new LLNL combustion dynamics data; improvements of techniques for chemical smoke aerosol analysis; development and test of a simple method to assess the corrosive potential of smoke aerosols; development of an initial aerosol dilution system; completion of primary small-scale tests for measurements of the dynamics of cable fires; finalization of primary survey format for non-LLNL energy technology facilities; and studies of fire dynamics and aerosol production from electrical insulation and computer tape cassettes

  4. Description of different techniques and their potentials of development for the reduction of nitrous oxides in the exhaust gases of waste incinerators and refuse-derived fuel-fired power plants in terms of performance, cost and power consumption; Beschreibung unterschiedlicher Techniken und deren Entwicklungspotentiale zur Minderung von Stickstoffoxiden im Abgas von Abfallverbrennungsanlagen und Ersatzbrennstoff-Kraftwerken hinsichtlich Leistungsfaehigkeit, Kosten und Energieverbrauch

    Energy Technology Data Exchange (ETDEWEB)

    Beckmann, Michael [Technische Univ. Dresden (Germany)

    2011-11-15

    On 22nd July, 2002 the European Parliament passes the sixth Environmental Action Programme of the European Community. According to this Programme, the environmental pollution can be reduced to a level at which adverse effects on human health have to be reduced. Under this aspect, the author of the contribution under consideration describes various techniques and their development potential for the reduction of nitrogen oxides in the exhaust of waste incinerators and refuse-derived fuel-fired power plants in terms of performance, cost and power consumption. Primary measures (air staging, flue gas recirculation) and secondary measures (SNCR, SCR process, combined procedure) were used as techniques.

  5. Refusal to medical interventions.

    Science.gov (United States)

    Palacios, G; Herreros, B; Pacho, E

    2014-10-01

    Refusal to medical interventions is the not acceptance, voluntary and free, of an indicated medical intervention. What the physician should do in case of refusal? It is understandable that the rejection of a validated medical intervention is difficult to accept by the responsible physician when raises the conflict protection of life versus freedom of choice. Therefore it is important to follow some steps to incorporate the most relevant aspects of the conflict. These steps include: 1) Give complete information to patients, informing on possible alternatives, 2) determine whether the patient can decide (age, competency and level of capacity), 3) to ascertain whether the decision is free, 4) analyze the decision with the patient, 5) to persuade, 6) if the patient kept in the rejection decision, consider conscientious objection, 7) take the decision based on the named criteria, 8) finally, if the rejection is accepted, offer available alternatives. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  6. Children with pervasive refusal.

    OpenAIRE

    Lask, B; Britten, C; Kroll, L; Magagna, J; Tranter, M

    1991-01-01

    Four children are described with a potentially life threatening condition manifested by profound and pervasive refusal to eat, drink, walk, talk, or care for themselves in any way over a period of several months. The multiplicity and severity of the symptoms in these children do not fit comfortably into any existing diagnostic category. Long term and highly skilled nursing and psychiatric care is required to help these children to recover. The possible causes of this syndrome are discussed.

  7. Construction products performances and basic requirements for fire safety of facades in energy rehabilitation of buildings

    Directory of Open Access Journals (Sweden)

    Laban Mirjana Đ.

    2015-01-01

    Full Text Available Construction product means any product or kit which is produced and placed on the market for incorporation in a permanent manner in construction works, or parts thereof, and the performance of which has an effect on the performance of the construction works with respect to the basic requirements for construction works. Safety in case of fire and Energy economy and heat retention represent two among seven basic requirements which building has to meet according to contemporary technical rules on planning and construction. Performances of external walls building materials (particularly reaction to fire could significantly affect to fire spread on the façade and other building parts. Therefore, façade shaping and materialization in building renewal process, has to meet the fire safety requirement, as well as the energy requirement. Brief survey of fire protection regulations development in Serbia is presented in the paper. Preventive measures for fire risk reduction in building façade energy renewal are proposed according to contemporary fire safety requirements.

  8. Review of fire protection in the nuclear facilities of the Atomic Energy Commission, 1947--1975

    International Nuclear Information System (INIS)

    Maybee, W.W.

    1979-01-01

    In the 28 years in which it grew from a temporary wartime bomb development program to a federal agency with over $30 billion worth of facilities housing much of the nation's advanced research efforts, the Atomic Energy Commission set many records for safety. Among the best was a cumulative fire loss ratio of 12 cents per $100 of value. A 1969 fire--one of four in its history that exceeded $1 million in loss--incurred damages totaling $26 million and prompted major additions to its fire protection programs. The added programs, encompassing additional fire protection engineers, new protection systems, independent inspection programs, and new performance-based goals, resulted in an order-of-magnitude improvement. The cumulative fire loss ratio after 1969 was 0.06 cents per $100 of value, a record few industries have ever achieved

  9. Feedlot biomass co-firing: a renewable energy alternative for coal-fired utilities. Paper no. IGEC-1-128

    International Nuclear Information System (INIS)

    Arumugam, S.; Thien, B.; Annamalai, K.; Sweeten, J.

    2005-01-01

    The swiftly growing feedlot industry in the United States upshots in the production of manure from one or more animal species in excess of what can safely be applied to farmland in accordance with nutrient management plans. Disposal of the vast quantity of manure produced as a by-product of the cattle feeding industry is one of the major operating tasks of the industry. Aside from the traditional means of disposal as fertilizer, an alternative and attractive way of overcoming this threat is to develop processes that make use of manure as an energy resource. In the present study, the feasibility of using of manure as a fuel in existing coal fired power plants is considered and appropriately termed Feedlot Biomass (FB). The technology of co-firing coal: feedlot biomass facilitates an environment friendly utilization of animal waste for the production of valuable power/steam concurrently addressing the renewable energy, groundwater contamination, and greenhouse gas concerns. Co-firing tests were performed at the Texas AandM University 30 kW t (100,000 Btu/h) laboratory-scale facility. The trials revealed the enhanced combustion of the blends. The NO emissions were less for the blend even with higher nitrogen content of FB as compared to coal. (author)

  10. Reliability estimation for multiunit nuclear and fossil-fired industrial energy systems

    International Nuclear Information System (INIS)

    Sullivan, W.G.; Wilson, J.V.; Klepper, O.H.

    1977-01-01

    As petroleum-based fuels grow increasingly scarce and costly, nuclear energy may become an important alternative source of industrial energy. Initial applications would most likely include a mix of fossil-fired and nuclear sources of process energy. A means for determining the overall reliability of these mixed systems is a fundamental aspect of demonstrating their feasibility to potential industrial users. Reliability data from nuclear and fossil-fired plants are presented, and several methods of applying these data for calculating the reliability of reasonably complex industrial energy supply systems are given. Reliability estimates made under a number of simplifying assumptions indicate that multiple nuclear units or a combination of nuclear and fossil-fired plants could provide adequate reliability to meet industrial requirements for continuity of service

  11. Compressive behavior of energy-saving fired facing brick composite wall

    Science.gov (United States)

    Guo, Kai; Wu, Cai

    2018-03-01

    The energy-saving fired facing brick composite wall has a broad development prospects due to its merits of thermal insulation, energy conservation, beautiful, and natural. The construction and characteristics of this wall are introduced and analyzed in this paper. Experimental studies of samples are also conducted to investigate its compressive performance. The results show that the energy-saving fired facing brick composite wall has high compressive capacity. It has considerable application prospect, the study in this paper provides foundation to further studies.

  12. Effective technology of wood and gaseous fuel co-firing for clean energy production

    International Nuclear Information System (INIS)

    Zake, M.; Barmina, I.; Gedrovics, M.; Desnickis, A.

    2007-01-01

    The main aim of the study was to develop and optimise a small-scale experimental co-firing technique for the effective and clean heat energy production by replacing a proportion of fossil fuel (propane) with renewable one (wood biomass). Technical solutions of propane co-fire presenting two different ways of additional heat supply to the wood biomass are proposed and analysed. The experiments have shown that a better result can be obtained for the direct propane co-fire of the wood biomass, when the rate of wood gasification and the ignition of volatiles are controlled by additional heat energy supply to the upper portion of wood biomass. A less effective though cleaner way of heat energy production is the direct propane co-fire of volatiles when low-temperature self-sustaining burnout of the wood biomass controls the rate of the volatile formation, while additional heat energy supply to the flow of volatiles controls their burnout. The effect of propane co-fire on the heat production rate and the composition of polluting emissions is studied and analysed for different rates of the additional heat supply to the wood biomass and of the swirling air supply as well as for different charge of wood biomass above the inlet of the propane flame flow. (Authors)

  13. Energy and water conservation at lignite-fired power plants using drying and water recovery technologies

    International Nuclear Information System (INIS)

    Liu, Ming; Qin, Yuanzhi; Yan, Hui; Han, Xiaoqu; Chong, Daotong

    2015-01-01

    Highlights: • Pre-drying and water recovery technologies were used to conserve energy and water. • The energy and water conservation potential were analyzed with reference cases. • The air-cooling unit produces water when the water content of lignite is high enough. • Influences of main parameters on energy and water conservation were analyzed. - Abstract: Lignite is considered as a competitive energy raw material with high security of supply viewed from a global angle. However, lignite-fired power plants have many shortcomings, including high investment, low energy efficiency and high water use. To address these issues, the drying and water recovery technologies are integrated within lignite-fired power plants. Both air-cooling and wet-cooling units with three kinds of lignite as feeding fuel were analyzed quantitatively. Results showed that energy conservation and water conservation are obtained simultaneously. The power plant firing high moisture lignite becomes more environmental friendly with higher power generation efficiency and a lower water makeup rate than the one firing low moisture lignite. And further calculation revealed that the air-cooling unit needs no makeup water and even produces some water as it generates power, when the water carrying coefficient is higher than 40 g/MJ.

  14. Ignition processes in the refuse bed of a refuse incineration plant. Gomi shokyakuro ni okeru gomi sonai no chakka katei

    Energy Technology Data Exchange (ETDEWEB)

    Goromaru, T; Onishi, K; Iwakawa, N; Yoshikuni, N [Fukuoka Univ., Fukuoka, (Japan)

    1990-03-01

    The ignition process was studied in this paper, which was particularly connected with the drying process of refuse in the statical characteristics of refuse incinerators. Because of variety in refuse forms to be supplied to the incinerators, a physical model was composed, assuming that refuse was the layers of piled up refuse elements with uniform forms, and the ignition curves of the layers were drawn on the basis of the above model after a mathematical model was formed. The upper part of the curves was altered so that it suits to actual endothermic and heat velocity distribution on the assumption of temperature distribution in the incinerators at their inlet side. No particular alteration was made in their middle part, then the ignition curves were changed to almost straight lines inclined downward. Unburnt and refuse under firing were wrapped by ash and uncombustibles, so the lower part of the curves was only studied as a imaginary solid model by the two methods of finite element method and simple analytical one, and conversion was made into equivalent reduction in combustion temperature. 15 refs., 7 figs., 2 tabs.

  15. Identifying and quantifying energy savings on fired plant using low cost modelling techniques

    International Nuclear Information System (INIS)

    Tucker, Robert; Ward, John

    2012-01-01

    Research highlights: → Furnace models based on the zone method for radiation calculation are described. → Validated steady-state and transient models have been developed. → We show how these simple models can identify the best options for saving energy. → High emissivity coatings predicted to give performance enhancement on a fired heater. → Optimal heat recovery strategies on a steel reheating furnace are predicted. -- Abstract: Combustion in fired heaters, boilers and furnaces often accounts for the major energy consumption on industrial processes. Small improvements in efficiency can result in large reductions in energy consumption, CO 2 emissions, and operating costs. This paper will describe some useful low cost modelling techniques based on the zone method to help identify energy saving opportunities on high temperature fuel-fired process plant. The zone method has for many decades, been successfully applied to small batch furnaces through to large steel-reheating furnaces, glass tanks, boilers and fired heaters on petrochemical plant. Zone models can simulate both steady-state furnace operation and more complex transient operation typical of a production environment. These models can be used to predict thermal efficiency and performance, and more importantly, to assist in identifying and predicting energy saving opportunities from such measures as: ·Improving air/fuel ratio and temperature controls. ·Improved insulation. ·Use of oxygen or oxygen enrichment. ·Air preheating via flue gas heat recovery. ·Modification to furnace geometry and hearth loading. There is also increasing interest in the application of refractory coatings for increasing surface radiation in fired plant. All of the techniques can yield savings ranging from a few percent upwards and can deliver rapid financial payback, but their evaluation often requires robust and reliable models in order to increase confidence in making financial investment decisions. This paper gives

  16. National policies. Cease-fire in the energy war

    Energy Technology Data Exchange (ETDEWEB)

    Beckman, K.

    2008-05-15

    In the energy war between producers and consumers that has been heating up in recent years, the ministerial gathering at the International Energy Forum (IEF) in Rome, Italy, April 2008 marked a ceasefire. But whether this leads to a permanent peace remains to be seen.

  17. Fire Danger of Interaction Processes of Local Sources with a Limited Energy Capacity and Condensed Substances

    OpenAIRE

    Glushkov, Dmitry Olegovich; Strizhak, Pavel Alexandrovich; Vershinina, Kseniya Yurievna

    2015-01-01

    Numerical investigation of flammable interaction processes of local energy sources with liquid condensed substances has been carried out. Basic integrated characteristic values of process have been defined – ignition delay time at different energy sources parameters. Recommendations have been formulated to ensure fire safety of technological processes, characterized by possible local heat sources formation (cutting, welding, friction, metal grinding etc.) in the vicinity of storage areas, tra...

  18. Fire Danger of Interaction Processes of Local Sources with a Limited Energy Capacity and Condensed Substances

    Directory of Open Access Journals (Sweden)

    Glushkov Dmitrii O.

    2015-01-01

    Full Text Available Numerical investigation of flammable interaction processes of local energy sources with liquid condensed substances has been carried out. Basic integrated characteristic values of process have been defined – ignition delay time at different energy sources parameters. Recommendations have been formulated to ensure fire safety of technological processes, characterized by possible local heat sources formation (cutting, welding, friction, metal grinding etc. in the vicinity of storage areas, transportation, transfer and processing of flammable liquids (gasoline, kerosene, diesel fuel.

  19. ANALISA KEHILANGAN ENERGI PADA FIRE TUBE BOILER KAPASITAS 10 TON

    Directory of Open Access Journals (Sweden)

    Aditio Primayudi Aji Nugroho

    2015-06-01

    Full Text Available Tujuan dari penulisan ini adalah menghitung kinerja boiler dengan mengetahui kerugian energi pada saat produksi steam. Analisa teknis pada boiler sangat diperlukan, sebagai upaya peningkatan efisiensi dan mengetahui banyaknya energi yang terbuang sebagai kerugian. Faktorfaktor penyebab kehilangan panas/heat loss terbesar pada boiler antara lain : “kehilangan panas akibat gas buang kering, kandungan steam dalam gas buang, kandungan air dalam bahan bakar, kandungan air dalam suplai udara dan lain-lain”.Kehilangan panas/heat loss atau juga bisa disebut kehilangan energi merupakan salah satu faktor penting yang sangat berpengaruh dalam mengidentifikasi efisiensi pada boiler.Untuk itu dilakukan studi analisa dengan perhitungan kehilangan panas dengan tujuan untuk mengetahui besarnya penurunan performance dan penyebab dari penurunan performance. Berdasarkan data dan analisa metode direct diketahui penurunan sebesar 21% pada kondisi normal (operasi 79% dan dari hasil perhitungan kehilangan panas indirect sebesar 16.68% efisiensi boiler sebesar 83.32% maka dari itu adanya kehilangan panas, perlu adanya perbaikan dalam control pengaturan bahan bakar dan udara yang masuk secara optimum dengan cara menggunakan Oxygen Trim Control yang berfungsi untuk mengukur konsentrasi oksigen pada cerobong dan secara otomatis mengatur oksigen pada udara yang masuk burner sehingga dihasilkan pembakaran dengan efisiensi yang optimal.dan dengan menggunakan economizer pada pemanasan awal suhu air umpan dapat menaikan efisiensi boiler.

  20. Elemental composition of suspended particles released in refuse incineration

    International Nuclear Information System (INIS)

    Mamuro, Tetsuo; Mizohata, Akira

    1979-01-01

    Suspended particles released in refuse incineration were subjected to multielement analysis by means of instrumental neutron activation method and energy dispersive X-ray fluorescence spectrometry. The analytical results were compared with the elemental concentrations observed in the urban atmosphere, and the contribution of the refuse incineration to the urban atmosphere was roughly estimated. Greenberg et al. pointed out on the basis of their analyses that the refuse incineration can account for major portions of the Zn, Cd and Sb observed on urban aerosols. According to our results, the contribution of the refuse incineration for Zn, Cd and Sb is not negligible, but not so serious as in U.S.A. big cities. In Japan big cities there must be other more important sources of these elements. (author)

  1. Assessment of musculoskeletal load in refuse collectors

    Directory of Open Access Journals (Sweden)

    Zbigniew W. Jóźwiak

    2013-08-01

    Full Text Available Background: The aim of this work was to assess the load on the musculoskeletal system and its effects in the collectors of solid refuse. The rationale behind this study was to formulate proposals how to reduce excessive musculoskeletal load in this group of workers. Material and Methods: The study group comprised 15 refuse collectors aged 25 to 50 years. Data about the workplace characteristics and subjective complaints of workers were collected by the free interview and questionnaire. During the survey the photorecording of the workpostures, the distance and velocity by GPS recorders, measurements of forces necessary to move containers, energy expenditure (lung ventilation method, workload estimation using the Firstbeat system and REBA method and stadiometry were done. Results: The distance walked daily by the collectors operating in terms of 2 to 3 in urban areas was about 15 km, and in rural areas about 18 km. The most frequent musculoskeletal complaints concerned the feet (60% subjects, knees, wrists and shoulders (over 40% subjects. After work-shift all examined workers had vertebral column shorter by 10 to 14 mm (11.4 mm mean. Conclusions: The results of our study show that the refuse collectors are subjected to a very high physical load because of the work organization and the way it is performed. To avoid adverse health effects and overload it is necessary to undertake ergonomic interventions, involving training of workers to improve the way of their job performance, active and passive leisure, technical control of the equipment and refuse containers, as well as the renegotiation of contracts with clients, especially those concerning non-standard containers. Med Pr 2013;64(4:507–519

  2. Solid waste as an energy source for the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Meier, P.M.; McCoy, T.H.

    1976-06-01

    This report, one of a series prepared for the BNL study of the Energy Future of the Northeastern United States, presents an assessment of the potential contribution of energy recovery from municipal refuse to energy supply in the region. A brief review of the present and likely future quantity and composition of municipal refuse and the technologies available for energy recovery (Chapters II and III) is followed by a comparison of the potential contributions to energy supply of the various recovery options including direct firing in utility boilers, pyrolysis to oil or gas, and steam generation for industrial process heat or district space heating (Chapter IV). The relationship of refuse energy recovery to market conditions for alternative energy sources is considered in Chapter V, which also includes an analysis of the impact of haul costs, interest rates, and delivered prices of the major fuels. Institutional barriers to implementation of energy recovery are reviewed in Chapter VI, and the environmental implications of the concept are addressed in Chapter VII. In the concluding chapters, scenarios of energy recovery are developed for 1985 and 2000, and the sensitivity of overall energy yield to projections and assumptions is examined. Although even under the most optimistic assumptions, refuse energy recovery is found to contribute only some 5 percent of total regional consumption, the economic and environmental benefits, coupled with the increasing difficulty of finding other refuse disposal alternatives, make energy recovery a very attractive policy choice for helping to relieve future energy supply difficulties in the Northeast. (auth)

  3. Study into the status of co-combustion of sewage sludge, biomass and household refuse in coal-fired power stations. Final report; Untersuchungen zum Stand der Mitverbrennung von Klaerschlamm, Hausmuell und Biomasse in Kohlekraftwerken. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hein, K.R.G.; Spliethoff, H.; Scheurer, W. [Stuttgart Univ. (Germany). Inst. fuer Verfahrenstechnik und Dampfkesselwesen; Seifert, H.; Richers, U. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer technische Chemie - Thermische Abfallbehandlung

    2000-03-01

    The co-combustion of wastes in power stations is an additional option for the thermal treatment of certain waste materials and thus for complying with the specifications of the German TA-Siedlungsabfall (technical directive on disposal of municipal solid waste). The present investigation compiles the status of knowledge about co-combustion of sewage sludge, biomass and selected waste materials in coal-fired power stations. The results are meant to provide extensive assistance to evaluate the processes and thus to contribute to sort out uncertainties, both on the part of power plant operators and of the authorities. Based on the information acquired, the report shall point out the gaps in knowledge, the further need for research and development and the need for action conerning the authorities. By enquiries at disposal enterprises, power station operators as well as authorities, the literature work was completed and a comprehensive view of the current situation in Germany elaborated. The report points out the legal conditions of co-combustion and supplementary fuel potentials, presents the process engineering of co-combustion, and examines the obstacles encountered during the technical conversion, the environmental questions, and the potential for co-combustion of the above materials in existing power stations. The electrical power sector is subject to strong changes due to the liberalisation of the energy market. The pressure on costs has increased and the periods available for planning are shorter. On the one hand, this arouses an increased interest in co-combustion of waste materials because of possible additional payments for the wastes. On the other hand, however, initiatives in this respect are counteracted by high investments costs necessary for the introduction of co-combustion with the existing high environmental standards. What is more, the competitive situation reduces the exchange of experience between the power station operators. Co-combustion of sewage

  4. Identification and characteristics of vaccine refusers

    OpenAIRE

    Wei, Feifei; Mullooly, John P; Goodman, Mike; McCarty, Maribet C; Hanson, Ann M; Crane, Bradley; Nordin, James D

    2009-01-01

    Abstract Background This study evaluated the utility of immunization registries in identifying vaccine refusals among children. Among refusers, we studied their socioeconomic characteristics and health care utilization patterns. Methods Medical records were reviewed to validate refusal status in the immunization registries of two health plans. Racial, education, and income characteristics of children claiming refusal were collected based on the census tract of each child. Health care utilizat...

  5. FireProt: Energy- and Evolution-Based Computational Design of Thermostable Multiple-Point Mutants.

    Science.gov (United States)

    Bednar, David; Beerens, Koen; Sebestova, Eva; Bendl, Jaroslav; Khare, Sagar; Chaloupkova, Radka; Prokop, Zbynek; Brezovsky, Jan; Baker, David; Damborsky, Jiri

    2015-11-01

    There is great interest in increasing proteins' stability to enhance their utility as biocatalysts, therapeutics, diagnostics and nanomaterials. Directed evolution is a powerful, but experimentally strenuous approach. Computational methods offer attractive alternatives. However, due to the limited reliability of predictions and potentially antagonistic effects of substitutions, only single-point mutations are usually predicted in silico, experimentally verified and then recombined in multiple-point mutants. Thus, substantial screening is still required. Here we present FireProt, a robust computational strategy for predicting highly stable multiple-point mutants that combines energy- and evolution-based approaches with smart filtering to identify additive stabilizing mutations. FireProt's reliability and applicability was demonstrated by validating its predictions against 656 mutations from the ProTherm database. We demonstrate that thermostability of the model enzymes haloalkane dehalogenase DhaA and γ-hexachlorocyclohexane dehydrochlorinase LinA can be substantially increased (ΔTm = 24°C and 21°C) by constructing and characterizing only a handful of multiple-point mutants. FireProt can be applied to any protein for which a tertiary structure and homologous sequences are available, and will facilitate the rapid development of robust proteins for biomedical and biotechnological applications.

  6. FireProt: Energy- and Evolution-Based Computational Design of Thermostable Multiple-Point Mutants.

    Directory of Open Access Journals (Sweden)

    David Bednar

    2015-11-01

    Full Text Available There is great interest in increasing proteins' stability to enhance their utility as biocatalysts, therapeutics, diagnostics and nanomaterials. Directed evolution is a powerful, but experimentally strenuous approach. Computational methods offer attractive alternatives. However, due to the limited reliability of predictions and potentially antagonistic effects of substitutions, only single-point mutations are usually predicted in silico, experimentally verified and then recombined in multiple-point mutants. Thus, substantial screening is still required. Here we present FireProt, a robust computational strategy for predicting highly stable multiple-point mutants that combines energy- and evolution-based approaches with smart filtering to identify additive stabilizing mutations. FireProt's reliability and applicability was demonstrated by validating its predictions against 656 mutations from the ProTherm database. We demonstrate that thermostability of the model enzymes haloalkane dehalogenase DhaA and γ-hexachlorocyclohexane dehydrochlorinase LinA can be substantially increased (ΔTm = 24°C and 21°C by constructing and characterizing only a handful of multiple-point mutants. FireProt can be applied to any protein for which a tertiary structure and homologous sequences are available, and will facilitate the rapid development of robust proteins for biomedical and biotechnological applications.

  7. Impending sources of energy to replace fire wood in semi arid climatic zones: A case study in Ethiopia

    Directory of Open Access Journals (Sweden)

    Mihret Dananto Ulsido

    2013-06-01

    Full Text Available The present study paper shows an alternative source of energy that can decrease the extensive use of fire wood in Ethiopia. The country’s entire rural area and significant part of urban population is completely dependent on fire wood as a source of energy. This practice takes its own toll, the forest is on the verge of being wiped out and as a result a clear change of climate and loss of natural biodiversity resources is visible. Fire wood is not the only source of energy available in the country. In this paper, based on their low cost, construction material availability and the required unskilled labor it is shown that biogas and solar energy are potentially feasible source of energy to replace firewood for cooking.

  8. 33 CFR 401.89 - Transit refused.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Transit refused. 401.89 Section... TRANSPORTATION SEAWAY REGULATIONS AND RULES Regulations General § 401.89 Transit refused. (a) An officer may refuse to allow a vessel to transit when, (1) The vessel is not equipped in accordance with §§ 401.5 to...

  9. The Research of Utilization Hours of Coal-Fired Power Generation Units Based on Electric Energy Balance

    Science.gov (United States)

    Liu, Junhui; Yang, Jianlian; Wang, Jiangbo; Yang, Meng; Tian, Chunzheng; He, Xinhui

    2018-01-01

    With grid-connected scale of clean energy such as wind power and photovoltaic power expanding rapidly and cross-province transmission scale being bigger, utilization hours of coal-fired power generation units become lower and lower in the context of the current slowdown in electricity demand. This paper analyzes the influencing factors from the three aspects of demand, supply and supply and demand balance, and the mathematical model has been constructed based on the electric energy balance. The utilization hours of coal-fired power generation units have been solved considering the relationship among proportion of various types of power installed capacity, the output rate and utilization hours. By carrying out empirical research in Henan Province, the utilization hours of coal-fired units of Henan Province in 2020 has been achieved. The example validates the practicability and the rationality of the model, which can provide a basis for the decision-making for coal-fired power generation enterprises.

  10. CO-COMBUSTION OF REFUSE DERIVED FUEL WITH COAL IN A FLUIDISED BED COMBUSTOR

    Directory of Open Access Journals (Sweden)

    W. A. WAN AB KARIM GHANI

    2009-03-01

    Full Text Available Power generation from biomass is an attractive technology which utilizes municipal solid waste-based refused derived fuel. In order to explain the behavior of biomass-fired fluidized bed incinerator, biomass sources from refuse derived fuel was co-fired with coal in a 0.15 m diameter and 2.3 m high fluidized bed combustor. The combustion efficiency and carbon monoxide emissions were studied and compared with those from pure coal combustion. This study proved that the blending effect had increased the carbon combustion efficiency up to 12% as compared to single MSW-based RDF. Carbon monoxide levels fluctuated between 200-1600 ppm were observed when coal is added. It is evident from this research that efficient co-firing of biomass with coal can be achieved with minimum modification of existing coal-fired boilers.

  11. Impact of Land Cover Change Induced by a Fire Event on the Surface Energy Fluxes Derived from Remote Sensing

    Directory of Open Access Journals (Sweden)

    Juan M. Sánchez

    2015-11-01

    Full Text Available Forest fires affect the natural cycle of the vegetation, and the structure and functioning of ecosystems. As a consequence of defoliation and vegetation mortality, surface energy flux patterns can suffer variations. Remote sensing techniques together with surface energy balance modeling offer the opportunity to explore these changes. In this paper we focus on a Mediterranean forest ecosystem. A fire event occurred in 2001 in Almodóvar del Pinar (Spain affecting a pine and shrub area. A two-source energy balance approach was applied to a set of Landsat 5-TM and Landsat 7-EMT+ images to estimate the surface fluxes in the area. Three post-fire periods were analyzed, six, seven, nine, and 11 years after the fire event. Results showed the regeneration of the shrub area in 6–7 years, in contrast to the pine area, where an important decrease in evapotranspiration, around 1 mm·day−1, remained. Differences in evapotranspiration were mitigated nine and 11 years after the fire in the pine area, whereas significant deviations in the rest of the terms of the energy balance equation were still observed. The combined effect of changes in the vegetation structure and surface variables, such as land surface temperature, albedo, or vegetation coverage, is responsible for these variations in the surface energy flux patterns.

  12. Feasibility study on energy conservation and reduction of CO2 emissions using RDF (refused derived fuel) at a Chinese cement plant

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The feasibility study was conducted on a project in China for energy saving and greenhouse gas emission reduction by introducing the energy-saving and alternative energy technologies in cement plants. The cement plant selected for the feasibility study is Shanghai Plant of Shanghai Allied Cement Co., Ltd. (SAC), for RDF receive and supply facility, chlorine bypass facility, exhaust heat power generation facility and RDF production facility. The study results indicate that the exhaust power generation can save energy of 4,700 tons/y as crude, or energy saving rate of 25.5%, and that replacing part of coal by RDF and exhaust power generation can reduce CO2 emissions by 25,500 and 18,500 tons/y, respectively. For the investment recovery, it is estimated that the investment can be recovered in 9 years, and the project value is 81.399 million Yuan with the initial investment and project profit in each year discounted to the present value. These results fail to satisfy the SAC's investment standards. (NEDO)

  13. Feasibility study on energy conservation and reduction of CO2 emissions using RDF (refused derived fuel) at a Chinese cement plant

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The feasibility study was conducted on a project in China for energy saving and greenhouse gas emission reduction by introducing the energy-saving and alternative energy technologies in cement plants. The cement plant selected for the feasibility study is Shanghai Plant of Shanghai Allied Cement Co., Ltd. (SAC), for RDF receive and supply facility, chlorine bypass facility, exhaust heat power generation facility and RDF production facility. The study results indicate that the exhaust power generation can save energy of 4,700 tons/y as crude, or energy saving rate of 25.5%, and that replacing part of coal by RDF and exhaust power generation can reduce CO2 emissions by 25,500 and 18,500 tons/y, respectively. For the investment recovery, it is estimated that the investment can be recovered in 9 years, and the project value is 81.399 million Yuan with the initial investment and project profit in each year discounted to the present value. These results fail to satisfy the SAC's investment standards. (NEDO)

  14. Separation of harmful impurities from refuse derived fuels (RDF) by a fluidized bed.

    Science.gov (United States)

    Krüger, B; Mrotzek, A; Wirtz, S

    2014-02-01

    In firing systems of cement production plants and coal-fired power plants, regular fossil fuels are increasingly substituted by alternative fuels. Rising energy prices and ambitious CO2-reduction goals promote the use of alternative fuels as a significant contribution to efficient energy recovery. One possibility to protect energy resources are refuse-derived fuels (RDF), which are produced during the treatment of municipal solid, commercial and industrial waste. The waste fractions suitable for RDF have a high calorific value and are often not suitable for material recycling. With current treatment processes, RDF still contains components which impede the utilization in firing systems or limit the degree of substitution. The content of these undesired components may amount to 4 wt%. These, in most cases incombustible particles which consist of mineral, ceramic and metallic materials can cause damages in the conveying systems (e. g. rotary feeder) or result in contaminations of the products (e. g. cement, chalk). Up-to-date separation processes (sieve machine, magnet separator or air classifier) have individual weaknesses that could hamper a secure separation of these particles. This article describes a new technology for the separation of impurities from refuse derived fuels based on a rotating fluidized bed. In this concept a rotating motion of the particle bed is obtained by the tangential injection of the fluidization gas in a static geometry. The RDF-particles experience a centrifugal force which fluidized the bed radially. The technical principle allows tearing up of particle clusters to single particles. Radially inwards the vertical velocity is much lower thus particles of every description can fall down there. For the subsequent separation of the particles by form and density an additionally cone shaped plate was installed in the centre. Impurities have a higher density and a compact form compared to combustible particles and can be separated with a high

  15. Water-Energy-Food Nexus in Asia-Pacific Ring of Fire

    Science.gov (United States)

    Taniguchi, M.; Endo, A.; Gurdak, J. J.; Allen, D. M.; Siringan, F.; Delinom, R.; Shoji, J.; Fujii, M.; Baba, K.

    2013-12-01

    Climate change and economic development are causing increased pressure on water, energy and food resources, presenting communities with increased levels of tradeoffs and potential conflicts among these resources. Therefore, the water-energy-food nexus is one of the most important and fundamental global environmental issues facing the world. For the purposes of this research project, we define human-environmental security as the joint optimization between human and environmental security as well as the water-energy-food nexus. To optimize the governance and management within these inter-connected needs, it is desirable to increase human-environmental security by improving social managements for the water-energy-food nexus. In this research project, we intend to establish a method to manage and optimize the human-environmental security of the water-energy-food nexus by using integrated models, indices, and maps as well as social and natural investigations with stakeholder analyses. We base our approach on the viewpoint that it is important for a sustainable society to increase human-environmental security with decreasing risk and increasing resilience by optimizing the connections within the critical water-energy and water-food clusters. We will take a regional perspective to address these global environmental problems. The geological and geomorphological conditions in our proposed study area are heavily influenced by the so-called 'Ring of Fire,' around the Pacific Ocean. Within these areas including Japan and Southeast Asia, the hydro-meteorological conditions are dominated by the Asia monsoon. The populations that live under these natural conditions face elevated risk and potential disaster as negative impacts, while also benefitting from positive ecological goods and services. There are therefore tradeoffs and conflicts within the water-energy-food nexus, as well as among various stakeholders in the region. The objective of this project is to maximize human

  16. Status quo of energy recovery from waste in special industrial facilities and evaluation of the environmental impacts of using refuse derived fuel (RDF) in cement kilns in Germany; Untersuchung der Umweltauswirkungen des Einsatzes von Abfaellen ausserhalb thermischer Abfallbehandlungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Alwast, H.; Marton, C.; Koepp, M.

    2001-10-01

    Within the study presented here the use of energy recovery from waste was analysed for several industrial facilities, focussing on cement plants, kilns in the lime and gypsum industry, steel works and plants for the production of non ferrous metals. 44 German cement plants dispose of an own clinker production. Presently 31 plants have a permit for recovering energy from waste. The total permitted capacity for energy recovery in German cement kilns amounts to nearly 2,6 Mio. t/a. Mainly waste oil, old tyres, fuel derived from processed production-specific and municipal waste, plastics, scrap wood and waste paper are co-incinerated. In 1998/99 a total amount of roughly 945.000 t refuse was processed in 30 units of the studied facilities. In five furnaces at three steel works waste can be used for energy or material recovery. The approved total capacity of high calorific waste for energy recovery comes to nearly 350,000 t/a. Especially industrial plastics and packaging waste from DSD, plastics processed in scrap mills and shreddered waste and granulated paint sludge are used. In 1998 the facilities processed only old plastic, representing a total amount of nearly 109.000 t. At present seven facilities in the non ferrous metal industry have a permit for energy recovery from waste. The maximum capacity amounts on national level to nearly 140.000 t/a. Especially waste oil, packaging waste, plastics and scrap wood can be processed. The analysis of respective applications of the 17th BImSchV shows an inconsistency within the amending permitting procedures. For the time to come a conformity between the respective regional permitting authorities would be recommendable. Moreover, the effects on air emission caused by using waste for energy recovery were analysed for cement kilns with own clinker production. Due to the amendment of the 17th BImSchV more stringent requirements regarding waste composition must be established. This is especially valid for the highly volatile

  17. School Refusal: Clinical Features, Diagnosis and Treatment

    Directory of Open Access Journals (Sweden)

    Kayhan Bahali

    2010-12-01

    Full Text Available Children regularly and voluntarily go to school in order to fulfill the expectations of society from them to continue their education or schooling. School continuation has been made compulsory by laws. Nonetheless, contrary to popular belief, for some children it is distressing to go to school. These children have difficulty continuing school and/or refuse to go to school. Today school refusal is defined as a child’s inability to continue school for reasons, such as anxiety and depression. The prevalence of school refusal has been reported to be approximately 1% in school-age children and 5% in child psychiatry samples. The prevalence of school refusal is similar among boys and girls. School refusal can occur at any time throughout the child’s academic life and at all socio-economic levels. School refusal is considered a symptom rather than a clinical diagnosis and can manifest itself as a sign of many psychiatric disorders, with anxiety disorders predominant. Separation anxiety disorder, generalized anxiety disorder, social phobia, specific phobia, and adjustment disorder with anxiety symptoms are the most common disorders co-occurring with school refusal. While separation anxiety disorder is associated with school refusal in younger children, other anxiety disorders, especially phobias, are associated with school refusal in adolescents. Children who have parents with psychiatric disorders have a higher incidence of school refusal, and psychiatric disorders are more frequently seen in adult relatives of children with school refusal, which supports a significant role of genetic and environmental factors in th etiology of school refusal. School refusal is a emergency state for child mental health. As it leads to detrimental effects in the short term and the long term, it should be regarded as a serious problem. The long-lasting follow-up studies of school refusing children have revealed that these children have a higher incidence of

  18. The Legal Ethical Backbone of Conscientious Refusal

    DEFF Research Database (Denmark)

    Munthe, Christian; Nielsen, Morten Ebbe Juul

    2017-01-01

    This article analyzes the idea of a legal right to conscientious refusal for healthcare professionals from a basic legal ethical standpoint, using refusal to perform tasks related to legal abortion (in cases of voluntary employment) as a case in point. The idea of a legal right to conscientious...... refusal is distinguished from ideas regarding moral rights or reasons related to conscientious refusal, and none of the latter are found to support the notion of a legal right. Reasons for allowing some sort of room for conscientious refusal for healthcare professionals based on the importance of cultural...... identity and the fostering of a critical atmosphere might provide some support, if no countervailing factors apply. One such factor is that a legal right to healthcare professionals’ conscientious refusal must comply with basic legal ethical tenets regarding the rule of law and equal treatment...

  19. High energy arcing fault fires in switchgear equipment : a literature review.

    Energy Technology Data Exchange (ETDEWEB)

    Nowlen, Steven Patrick; Brown, Jason W.; Wyant, Francis John

    2008-10-01

    In power generating plants, switchgear provide a means to isolate and de-energize specific electrical components and buses in order to clear downstream faults, perform routine maintenance, and replace necessary electrical equipment. These protective devices may be categorized by the insulating medium, such as air or oil, and are typically specified by voltage classes, i.e. low, medium, and high voltage. Given their high energy content, catastrophic failure of switchgear by means of a high energy arcing fault (HEAF) may occur. An incident such as this may lead to an explosion and fire within the switchgear, directly impact adjacent components, and possibly render dependent electrical equipment inoperable. Historically, HEAF events have been poorly documented and discussed in little detail. Recent incidents involving switchgear components at nuclear power plants, however, were scrupulously investigated. The phenomena itself is only understood on a very elementary level from preliminary experiments and theories; though many have argued that these early experiments were inaccurate due to primitive instrumentation or poorly justified methodologies and thus require re-evaluation. Within the past two decades, however, there has been a resurgence of research that analyzes previous work and modern technology. Developing a greater understanding of the HEAF phenomena, in particular the affects on switchgear equipment and other associated switching components, would allow power generating industries to minimize and possibly prevent future occurrences, thereby reducing costs associated with repair and downtime. This report presents the findings of a literature review focused on arc fault studies for electrical switching equipment. The specific objective of this review was to assess the availability of the types of information needed to support development of improved treatment methods in fire Probabilistic Risk Assessment (PRA) for nuclear power plant applications.

  20. Effect of air ingress on the energy performance of coal fired thermal power plants

    International Nuclear Information System (INIS)

    Siddhartha Bhatt, M.

    2007-01-01

    Ingress of air in boilers leads to drops in energy efficiency. This paper presents the effects of air ingress in the combustion zone, post-combustion zone and air pre-heater (APH) on the energy efficiency and loading capacity of a coal fired thermal power plant operating on fuel with high ash (35-45%). The optimal O 2 in the flue gas for a pulverized coal fired system is 3.5% (corresponding to 20% excess air). The operating values are in the range of 4.2-6.0% in membrane type boilers and up to 10% in refractory type boilers (after sustained periods of operation). The leakage rate of boilers (up to the entrance of the APH) is designed at 0.2% while the average operating values are 7.25% for membrane type enclosures and 33.61% for refractory enclosures. The leakage rate of the APH is designed at 5.0% while the operating values range from 13.66% to 20.13% for rotary and tubular APHs. When the O 2 in the combustion zone varies from 3.5% to 8.0%, efficiency drops of 2.0% points are experienced in the boiler and turbine separately, and the gross overall efficiency drop is ∼3.0% points. The units do not experience any capacity drop up to an O 2 in the flue gas of 6.0% before the APH. At an O 2 in the flue gas (before APH) of 7.2%, a mild limitation on the unit capacity of around 2-3% is experienced. When O 2 in the flue gas (before APH) reaches a level of 9.0%, 20% capacity drop of the unit is experienced due to which the plant load cannot be raised higher than 80%. Beyond the level of 9.0% (rare occurrence), the unit is quite difficult to operate and has to be taken off for overhaul

  1. An overview of the political, technical and economical aspects of gas-fired distributed energy system in China

    International Nuclear Information System (INIS)

    Chen, Qiaohui; Wang, Weilong; Lu, Jianfeng; Ding, Jing

    2013-01-01

    The interest in distributed energy system has been increasing in China in recent years due to the environmental and energy policy concerns. The distributed energy system generates power, heating and cooling to residential, commercial and industrial facilities. Due to cascade utilization of energy, it can make good use of energy to improve energy efficiency and to increase energy savings. Furthermore, it consumes less energy and reduces carbon emissions. This paper reviews existing and newly-built gas-fired distributed energy projects in China. The techno-economic assessment of the selected projects has also been discussed and reported. The results show that in Xiamen Jimei DE project, the primary energy ratio of the DES can be as high as 92.9%, and energy-saving rate is 35.5%. Moreover, exergy efficiency reaches 54.3%, and the system can reduce 0.52 million tons of CO 2 annually. -- Highlights: ► The political, technical and economical aspects of gas-fired DES are analyzed. ► The techno-economic assessment of two selected projects is conducted. ► Primary energy ratio can be as high as 92.9% and energy-saving rate is 35.5%. ► Exergy efficiency is 54.3% and the system can reduce a large amount of CO 2 emissions

  2. Effects of invasive insects and fire on energy exchange and evapotranspiration in the New Jersey pine lands

    Science.gov (United States)

    Kenneth L. Clark; Nicholas Skowronski; Michael Gallagher; Hedi Renninger; Karina. Schafer

    2012-01-01

    We used eddy covariance and meteorological measurements to quantify energy exchange and evapotranspiration (Et) in three representative upland forest stands in the New Jersey Pinelands that were either defoliated by gypsy moth (Lymantria dispar L.) or burned in prescribed fires during the study period. Latent (λE) and sensible heat (H)...

  3. 30 CFR 816.83 - Coal mine waste: Refuse piles.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal mine waste: Refuse piles. 816.83 Section... ACTIVITIES § 816.83 Coal mine waste: Refuse piles. Refuse piles shall meet the requirements of § 816.81, the... drainage may not be diverted over the outslope of the refuse piles. Runoff from the areas above the refuse...

  4. 30 CFR 817.83 - Coal mine waste: Refuse piles.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal mine waste: Refuse piles. 817.83 Section... ACTIVITIES § 817.83 Coal mine waste: Refuse piles. Refuse piles shall meet the requirements of § 817.81, the... drainage may not be diverted over the outslope of the refuse pile. Runoff from areas above the refuse pile...

  5. Gas fired combined cycle plant in Singapore: energy use, GWP and cost-a life cycle approach

    International Nuclear Information System (INIS)

    Kannan, R.; Leong, K.C.; Osman, Ramli; Ho, H.K.; Tso, C.P.

    2005-01-01

    A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle power plant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle power plant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established

  6. Effect of water side deposits on the energy performance of coal fired thermal power plants

    International Nuclear Information System (INIS)

    Bhatt, M. Siddhartha

    2006-01-01

    This paper presents the effects of water side deposits in the 210 MW coal fired thermal power plant components (viz., boiler, turbine, feed water heaters, condensers and lube oil coolers) on the energy efficiency of these components and that of the overall system at 100% maximum continuous rating (MCR). The origin, composition and rate of build up of deposits on the water side are presented. A linear growth rate of deposits is assumed for simplicity. The effects of the reduction in heat transfer, increased pressure drop and increased pumping power/reduced power output in the components are quantified in the form of curve fits as functions of the deposit thickness (μm). The reduction in heat transfer in the boiler components is in the range of 0.2-2.0% under normal scaling. The increased pumping power is of the order of 0.6-7.6% in the boiler components, 29% in the BFP circuit, 26% in the LPH circuit, 21% in the HPH circuit and 18% in the lube oil cooler circuits. The effects on the overall coal fired plant is quantified through functional relations between the efficiencies and the notional deposit thickness. The sensitivity indices to the notional deposit thickness are: boiler efficiency: -0.0021% points/μm, turbine circuit efficiency: -0.0037% points/μm, auxiliary power efficiency: -0.00129% points/μm, gross overall efficiency: -0.0039% points/μm and net overall efficiency: -0.0040% points/μm. The overall effect of scale build up is either increased power input of ∼68 kW/μm (at a constant power output) or decreased power output ∼25 kW/μm (at a constant power input). Successful contaminant control techniques are highlighted. Capacity reduction effects due to water side deposits are negligible

  7. Feasibility of a medium-size central cogenerated energy facility, energy management memorandum

    Science.gov (United States)

    Porter, R. W.

    1982-09-01

    The thermal-economic feasibility was studied of a medium-size central cogenerated energy facility designed to serve five varied industries. Generation options included one dual-fuel diesel and one gas turbine, both with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired-boiler cases, also low-sulphur coal and municipal refuse. The fired-boiler cogeneration systems employed back-pressure steam turbines. For coal and refuse, the option of steam only without cogeneration was also assessed. The refuse-fired cases utilized modular incinerators. The options provided for a wide range of steam and electrical capacities. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which could be displaced was assumed sold to Commonwealth Edison Company under PURPA (Public Utility Regulator Policies Act). The facility was assumed operated by a mutually owned corporation formed by the cogenerated power users. The economic analysis was predicted on currently applicable energy-investment tax credits and accelerated depreciation for a January 1985 startup date. Based on 100% equity financing, the results indicated that the best alternative was the modular-incinerator cogeneration system.

  8. Personal values and cancer treatment refusal

    NARCIS (Netherlands)

    Evert van Leeuwen; Marli Huijer

    2000-01-01

    This pilot study explores the reasons patients have for refusing chemotherapy, and the ways oncologists respond to them. Our hypothesis, generated from interviews with patients and oncologists, is that an ethical approach that views a refusal as an autonomous choice, in which patients are informed

  9. [Refusal of nursing care, the legal perspective].

    Science.gov (United States)

    Fisman, Jérôme

    2016-10-01

    The refusal of nursing care forms part of the freedom offered to anyone wanting to refuse, consciously and knowingly, any form of nursing care such as washing, the taking of medication or hospitalisation. However, limits are fixed by law as well as by case law. Are we totally free in the expression of our will? Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Energy Analysis and Environmental Impacts of Hybrid Giant Napier (Pennisetum Hydridum) Direct-fired Power Generation in South China

    Science.gov (United States)

    Liao, Yanfen; Fang, Hailin; Zhang, Hengjin; Yu, Zhaosheng; Liu, Zhichao; Ma, Xiaoqian

    2017-05-01

    To meet with the demand of energy conservation and emission reduction policies, the method of life cycle assessment (LCA) was used to assess the feasibility of Hybrid Giant Napier (HGN) direct-fired power generation in this study. The entire life cycle is consisted of five stages (cultivation and harvesting, transportation, drying and comminuting, direct-fired power generation, constructing and decommissioning of biomass power plant). Analytical results revealed that to generate 10000kWh electricity, 10.925 t of customized HGN fuel (moisture content: 30 wt%) and 6659.430 MJ of energy were required. The total environmental impact potential was 0.927 PET2010 (person equivalents, targeted, in 2010) and the global warming (GW), acidification (AC), and nutrient (NE) emissions were 339.235 kg CO2-eq, 22.033 kg SO2-eq, and 25.486 kg NOx-eq respectively. The effect of AC was the most serious among all calculated category impacts. The energy requirements and environmental impacts were found to be sensitive to single yield, average transport distance, cutting frequency, and moisture content. The results indicated that HGN direct-fired power generation accorded well with Chinese energy planning; in addition, HGN proved to be a promising contribution to reducing non-renewable energy consumption and had encouraging prospects as a renewable energy plant.

  11. The importance of fossil-fired power plants for the future energy supply

    International Nuclear Information System (INIS)

    Czychon, K.H.

    2013-01-01

    In response to the nuclear disaster in Fukushima and the phasing out of nuclear energy in Germany which is planned up to the year 2022, in addition to the already decommissioned nuclear power plants, a further outage capacity of approximately 13 MW will result. Against the background of the unresolved storage problem, regardless of further expansion of the use of renewable energy sources, the need arises for additional fossil-fueled power plants, i.e. gas and coal power plants. The development of gas prices shows that a further expansion of the gas turbine power plants is limited for economic reasons. This leads to the consequence that the future coal-fired power plants are needed to produce electricity. To meet the requirements for a reduction of CO 2 emissions laws, new power plants must be built with increased efficiency compared to previous systems. In order to meet the challenges of future fossil fuel power plant generations, the Grosskraftwerk Mannheim (Large-scale Power Plant Mannheim) is involved in numerous research projects to increase efficiency, reduce harmful emissions and economic implementation of ambitious technologies.

  12. Caregivers who refuse preventive care for their children: the relationship between immunization and topical fluoride refusal.

    Science.gov (United States)

    Chi, Donald L

    2014-07-01

    The aim of this study was to examine caregivers' refusal of preventive medical and dental care for children. Prevalence rates of topical fluoride refusal based on dental records and caregiver self-reports were estimated for children treated in 3 dental clinics in Washington State. A 60-item survey was administered to 1024 caregivers to evaluate the association between immunization and topical fluoride refusal. Modified Poisson regression models were used to estimate prevalence rate ratios (PRRs). The prevalence of topical fluoride refusal was 4.9% according to dental records and 12.7% according to caregiver self-reports. The rate of immunization refusal was 27.4%. In the regression models, immunization refusal was significantly associated with topical fluoride refusal (dental record PRR = 1.61; 95% confidence interval [CI] = 1.32, 1.96; P refuse both immunizations and topical fluoride (P refusal of immunizations is associated with topical fluoride refusal. Future research should identify the behavioral and social factors related to caregiver refusal of preventive care with the goal of developing multidisciplinary strategies to help caregivers make optimal preventive care decisions for children.

  13. Refuse derived fuel potential in DKI Jakarta

    Science.gov (United States)

    Widyatmoko, H.

    2018-01-01

    Combustible waste fractions of municipal solid waste (MSW) which can not be easily separated or sorted, reused or recycled, may have a high calorifiv value (CV) that can be used in a fuel for energy recovery. The objective of this study was to explore the Refuse Derived Fuel (RDF) potential of municipal solid waste from DKI Jakarta to produce electricity and to promote it to be socially and politically acceptable. For this purpose, 24 sampels of RDF were taken from Bantargebang, cabonized, molded and pressed to be briquette. All samples were analized for moisture, ash, and calorific value in the physical and chemistry Laboratory of ITB Bandung. The analysis of calorific value (CV) shows the CV difference of 1815.8 cal/g between the briquettes (8051.25 cal/g) and the RDF (9867.12 cal/g. The total waste DKI which can be used as briquettes 5253 ton / day or equivalent with 49154115 kWh / day. If the efficiency of electricity production from RDF was 25%, then Jakarta is able to generate electricity from RDF of 12288529 kWh / day or as much as energy needed by 573,480 middle-class households with energy needs of 642.84 kWh/month.

  14. Project Startup: Evaluating the Performance of Hydraulic Hybrid Refuse Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    The Fleet Test and Evaluation Team at the National Renewable Energy Laboratory (NREL) is evaluating the in-service performance of 10 next-generation hydraulic hybrid refuse vehicles (HHVs), 8 previous-generation HHVs, and 8 comparable conventional diesel vehicles operated by Miami-Dade County's Public Works and Waste Management Department in southern Florida. The HHVs under study - Autocar E3 refuse trucks equipped with Parker Hannifin's RunWise Advanced Series Hybrid Drive systems - can recover as much as 70 percent of the energy typically lost during braking and reuse it to power the vehicle. NREL's evaluation will assess the performance of this technology in commercial operation and help Miami-Dade County determine the ideal routes for maximizing the fuel-saving potential of its HHVs.

  15. Nuclear energy cost data base: A reference data base for nuclear and coal-fired powerplant power generation cost analysis

    International Nuclear Information System (INIS)

    1988-09-01

    A reference data base and standard methodology are needed for performing comparative nuclear and fossil power generation cost analyses for the Department of Energy, Office of Nuclear Energy. This report contains such a methodology together with reference assumptions and data to be used with the methodology. It is intended to provide basic guidelines or a starting point for analyses and to serve as a focal point in establishing parameters and methods to be used in economic comparisons of nuclear systems with alternatives. The data base is applicable for economic comparisons of new base load light-water reactors on a once-through cycle, and high- and low-sulfur coal-fired plants, and oil- and natural gas-fired electric generating plants coming on line around the turn of the century. In addition to current generation light-water reactors and fossil fuel-fired plants, preliminary cost information is also presented on improved and advanced light-water reactors, liquid metal reactor plants and fuel cycle facilities. This report includes an updated data base containing proposed technical and economic assumptions to be used in analyses, discussions of a recommended methodology to be used in calculating power generation costs, a sample calculation for illustrative and benchmark purposes and projected power generation costs for fission and coal-fired alternatives. Effects of the 1986 Tax Reform Act are included. 126 refs., 17 figs., 47 tabs

  16. The Legal Ethical Backbone of Conscientious Refusal.

    Science.gov (United States)

    Munthe, Christian; Nielsen, Morten Ebbe Juul

    2017-01-01

    This article analyzes the idea of a legal right to conscientious refusal for healthcare professionals from a basic legal ethical standpoint, using refusal to perform tasks related to legal abortion (in cases of voluntary employment) as a case in point. The idea of a legal right to conscientious refusal is distinguished from ideas regarding moral rights or reasons related to conscientious refusal, and none of the latter are found to support the notion of a legal right. Reasons for allowing some sort of room for conscientious refusal for healthcare professionals based on the importance of cultural identity and the fostering of a critical atmosphere might provide some support, if no countervailing factors apply. One such factor is that a legal right to healthcare professionals' conscientious refusal must comply with basic legal ethical tenets regarding the rule of law and equal treatment, and this requirement is found to create serious problems for those wishing to defend the idea under consideration. We conclude that the notion of a legal right to conscientious refusal for any profession is either fundamentally incompatible with elementary legal ethical requirements, or implausible because it undermines the functioning of a related professional sector (healthcare) or even of society as a whole.

  17. Legal briefing: conscience clauses and conscientious refusal.

    Science.gov (United States)

    Pope, Thaddeus Mason

    2010-01-01

    This issue's "Legal Briefing" column covers legal developments pertaining to conscience clauses and conscientious refusal. Not only has this topic been the subject of recent articles in this journal, but it has also been the subject of numerous public and professional discussions. Over the past several months, conscientious refusal disputes have had an unusually high profile not only in courthouses, but also in legislative and regulatory halls across the United States. Healthcare providers' own moral beliefs have been obstructing and are expected to increasingly obstruct patients' access to medical services. For example, some providers, on ethical or moral grounds, have denied: (1) sterilization procedures to pregnant patients, (2) pain medications in end-of-life situations, and (3) information about emergency contraception to rape victims. On the other hand, many healthcare providers have been forced to provide medical treatment that is inconsistent with their moral beliefs. There are two fundamental types of conscientious objection laws. First, there are laws that permit healthcare workers to refuse providing - on ethical, moral, or religious grounds healthcare services that they might otherwise have a legal or employer-mandated obligation to provide. Second, there are laws directed at forcing healthcare workers to provide services to which they might have ethical, moral, or religious objections. Both types of laws are rarely comprehensive, but instead target: (1) certain types of healthcare providers, (2) specific categories of healthcare services, (3) specific patient circumstances, and (4) certain conditions under which a right or obligation is triggered. For the sake of clarity, I have grouped recent legal developments concerning conscientious refusal into eight categories: 1. Abortion: right to refuse 2. Abortion: duty to provide 3. Contraception: right to refuse 4. Contraception: duty to provide 5. Sterilization: right to refuse 6. Fertility, HIV, vaccines

  18. Equipment sizing in a coal-fired municipal heating plant modernisation project with support for renewable energy and cogeneration technologies

    International Nuclear Information System (INIS)

    Kalina, Jacek

    2014-01-01

    Highlights: • Sizing of biomass fired cogeneration block is performed for existing heating plant. • Mathematical model for cogeneration block optimisation is presented. • Impact of financial support mechanisms on optimal solution is discussed. • Influence of short term variations of prices and support intensity is presented. • Different design parameters are suggested by economic and technical quality indices. - Abstract: The paper presents results of design parameters optimisation of a wood chips fired steam boiler based heat and power block in a sample project of coal fired municipal heating plant modernisation. The project assumes the conversion of the heating plant into a dual fuel heat and power plant. The problem that is presented is selection of cogeneration block structure and thermodynamic parameters taking into account financial support mechanisms for cogeneration and renewable energy technologies. There are examined energy conversion and financial performances of the project. The results show that without the financial support the project is not profitable although it generates savings of primary energy of fossil fuels. If an administrative incentives are applied the optimal technical solution is different than suggested by energy conversion efficiency or fossil fuel savings. Financial calculations were performed for Polish marked conditions in the years 2011 and 2014 showing the impact of relatively short term variations of prices and support intensity on optimal plant design parameters

  19. Direct energy balance based active disturbance rejection control for coal-fired power plant.

    Science.gov (United States)

    Sun, Li; Hua, Qingsong; Li, Donghai; Pan, Lei; Xue, Yali; Lee, Kwang Y

    2017-09-01

    The conventional direct energy balance (DEB) based PI control can fulfill the fundamental tracking requirements of the coal-fired power plant. However, it is challenging to deal with the cases when the coal quality variation is present. To this end, this paper introduces the active disturbance rejection control (ADRC) to the DEB structure, where the coal quality variation is deemed as a kind of unknown disturbance that can be estimated and mitigated promptly. Firstly, the nonlinearity of a recent power plant model is analyzed based on the gap metric, which provides guidance on how to set the pressure set-point in line with the power demand. Secondly, the approximate decoupling effect of the DEB structure is analyzed based on the relative gain analysis in frequency domain. Finally, the synthesis of the DEB based ADRC control system is carried out based on multi-objective optimization. The optimized ADRC results show that the integrated absolute error (IAE) indices of the tracking performances in both loops can be simultaneously improved, in comparison with the DEB based PI control and H ∞ control system. The regulation performance in the presence of the coal quality variation is significantly improved under the ADRC control scheme. Moreover, the robustness of the proposed strategy is shown comparable with the H ∞ control. Copyright © 2017. Published by Elsevier Ltd.

  20. Computerized information system on the impacts of coal-fired energy development in the Southwest

    International Nuclear Information System (INIS)

    Layton, D.W.

    1975-01-01

    An important part of the process of assessing the environmental impacts of coal-fired energy development in the Southwest is the transfer of information between electric utilities, federal agencies, and the interested public. There are, however, several problems associated with the transfer of information among the different groups. The acquisition of factual material on power projects by the interested public, for example, is adversely affected by the sufficiency, convenience, and credibility of present sources. Efforts of electric utilities and federal agencies to effectively communicate impact information are hindered by the inability of existing sources to selectively transfer information and to rapidly transmit information on the cumulative impacts of many combinations of power plants. This research concerns the development and evaluation of a computerized information system designed to selectively transfer information on both the cumulative and individual impacts of several electric generating facilities located in the southwestern United States. The information system incorporates features of management information systems, environmental information systems, and an issue-oriented system developed at The University of Illinois, making it a hybrid system capable of communicating impact information derived from a variety of sources

  1. Resource potential for renewable energy generation from co-firing of woody biomass with coal in the Northern U.S.

    Science.gov (United States)

    Michael E. Goerndt; Francisco X. Aguilar; Kenneth Skog

    2013-01-01

    Past studies have established measures of co-firing potential at varying spatial scales to assess opportunities for renewable energy generation from woody biomass. This study estimated physical availability, within ecological and public policy constraints, and associated harvesting and delivery costs of woody biomass for co-firing in selected power plants of the...

  2. A data envelopment analysis for energy efficiency of coal-fired power units in China

    International Nuclear Information System (INIS)

    Song, Chenxi; Li, Mingjia; Zhang, Fan; He, Ya-Ling; Tao, Wen-Quan

    2015-01-01

    Highlights: • Two kinds of energy efficiency (EE) indices are analyzed and compared. • The influence degrees of different uncontrollable factors on EE are compared. • The influence of load factor on special EE is 82.6% larger than capacity factor. • The influence of cooling method on special EE is 90.32% larger than steam pressure. • The generalized EE indicator is more recommended by the authors. - Abstract: In this article, the non-parametric data envelopment analysis method (DEA) is employed to evaluate energy efficiency (EE) of 34 coal-fired power units in China. Input-oriented CCR (Charnes, Cooper and Rhodes) model is used for EE analysis. Two efficiency indices, generalized EE and special EE are defined and analyzed. The generalized EE is calculated based on four input parameters: coal consumption, oil consumption, water consumption and auxiliary power consumption by power units. The special EE is only based on two input parameters: coal consumption and auxiliary power consumption. Relations between these two EE indices and non-comparable factors including quality of coal, load factor, capacity factor, parameters of main steam and cooling method are studied. Comparison between EE evaluation results of the two indices is conducted. Results show that these two kinds of EE are more sensitive to the load factor than the capacity factor. The influence of the cooling method on EE is larger than that of main steam parameter. The influence of non-comparable factors on the special EE is stronger than that on the generalized EE

  3. The use of remotely-sensed wildland fire radiation to infer the fates of carbon during biomass combustion - the need to understand and quantify a fire's mass and energy budget

    Science.gov (United States)

    Dickinson, M. B.; Dietenberger, M.; Ellicott, E. A.; Hardy, C.; Hudak, A. T.; Kremens, R.; Mathews, W.; Schroeder, W.; Smith, A. M.; Strand, E. K.

    2016-12-01

    Few measurement techniques offer broad-scale insight on the extent and characteristics of biomass combustion during wildland fires. Remotely-sensed radiation is one of these techniques but its measurement suffers from several limitations and, when quantified, its use to derive variables of real interest depends on an understanding of the fire's mass and energy budget. In this talk, we will review certain assumptions of wildland fire radiation measurement and explore the use of those measurements to infer the fates of biomass and the dissipation of combustion energy. Recent measurements show that the perspective of the sensor (nadir vs oblique) matters relative to estimates of fire radiated power. Other considerations for producing accurate estimates of fire radiation from remote sensing include obscuration by an intervening forest canopy and to what extent measurements that are based on the assumption of graybody/blackbody behavior underestimate fire radiation. Fire radiation measurements are generally a means of quantifying other variables and are often not of interest in and of themselves. Use of fire radiation measurements as a means of inference currently relies on correlations with variables of interest such as biomass consumption and sensible and latent heat and emissions fluxes. Radiation is an imperfect basis for these correlations in that it accounts for a minority of combustion energy ( 15-30%) and is not a constant as is often assumed. Measurements suggest that fire convective energy accounts for the majority of combustion energy and (after radiation) is followed by latent energy, soil heating, and pyrolysis energy, more or less in that order. Combustion energy in and of itself is not its potential maximum, but is reduced to an effective heat of combustion by combustion inefficiency and by work done to pyrolyze fuel (important in char production) and in moisture vaporization. The effective heat of combustion is often on the order of 65% of its potential

  4. Summary of fire protection programs of the United States Department of Energy

    International Nuclear Information System (INIS)

    1991-10-01

    This edition of the Annual Summary of DOE Fire Protection Programs continues the series started in 1972. Since May 1950, an annual report has been required from each field organization. The content has varied through the years and most of the accident data reporting requirements have been superseded by the Computerized Accident/Incident Reporting System administered by EG ampersand G, Idaho. However, this report is the sole source of information relating to fire protection programs, and to the actions of the field offices and to headquarters that are of general fire protection interest

  5. Fire-induced albedo change and surface radiative forcing in sub-Saharan Africa savanna ecosystems: Implications for the energy balance

    Science.gov (United States)

    Dintwe, Kebonye; Okin, Gregory S.; Xue, Yongkang

    2017-06-01

    Surface albedo is a critical parameter that controls surface energy balance. In dryland ecosystems, fires play a significant role in decreasing surface albedo, resulting in positive radiative forcing. Here we investigate the long-term effect of fire on surface albedo. We devised a method to calculate short-, medium-, and long-term effect of fire-induced radiative forcing and their relative effects on energy balance. We used Moderate Resolution Imaging Spectroradiometer (MODIS) data in our analysis, covering different vegetation classes in sub-Saharan Africa (SSA). Our analysis indicated that mean short-term fire-induced albedo change in SSA was -0.022, -0.035, and -0.041 for savannas, shrubland, and grasslands, respectively. At regional scale, mean fire-induced albedo change in savannas was -0.018 and -0.024 for northern sub-Saharan of Africa and the southern hemisphere Africa, respectively. The short-term mean fire-induced radiative forcing in burned areas in sub-Saharan Africa (SSA) was 5.41 W m-2, which contributed continental and global radiative forcings of 0.25 and 0.058 W m-2, respectively. The impact of fire in surface albedo has long-lasting effects that varies with vegetation type. The long-term energetic effects of fire-induced albedo change and associated radiative forcing were, on average, more than 19 times greater across SSA than the short-term effects, suggesting that fires exerted far more radiative forcing than previously thought. Taking into account the actual duration of fire's effect on surface albedo, we conclude that the contribution of SSA fires, globally and throughout the year, is 0.12 W m-2. These findings provide crucial information on possible impact of fire on regional climate variability.

  6. Chemical reagent and process for refuse disposal

    International Nuclear Information System (INIS)

    Somerville, R.B.; Fan, L.T.

    1989-01-01

    A process for treating refuse by mixing them with a reactive chemical and a puzzolana-type material. Said chemical includes a retarding agent which modifies the viscosity and an accelerating agent. (author)

  7. Using a Nonaversive Procedure to Decrease Refusals.

    Science.gov (United States)

    Spooner, Fred; And Others

    1990-01-01

    A nonaversive technique was used to teach a severely handicapped woman to decrease her refusals. The technique employed precision teaching via precise daily measurement strategies, environmental analysis, and a focus on building appropriate behavior. (JDD)

  8. When does food refusal require professional intervention?

    OpenAIRE

    Dovey, Terence M.; Farrow, Claire V.; Martin, Clarissa I.; Isherwood, Elaine; Halford, Jason C.G.

    2009-01-01

    Food refusal can have the potential to lead to nutritional deficiencies, which increases the risk of a variety of communicable and non-communicable diseases. Deciding when food refusal requires professional intervention is complicated by the fact that there is a natural and appropriate stage in a child's development that is characterised by increased levels of rejection of both previously accepted and novel food items. Therefore, choosing to intervene is difficult, which if handled badly can ...

  9. 30 CFR 77.215-4 - Refuse piles; abandonment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Refuse piles; abandonment. 77.215-4 Section 77... MINES Surface Installations § 77.215-4 Refuse piles; abandonment. When a refuse pile is to be abandoned... refuse pile shall be abandoned in accordance with a plan submitted by the operator and approved by the...

  10. Power generation from refuse derived fuel

    International Nuclear Information System (INIS)

    Surroop, Dinesh; Mohee, Romeela

    2010-01-01

    Full text: The beginning of the third millennium has been characterized by a progressive increase in the demand for fossil fuels, which has caused a steep rise in oil price. At the same time, several environmental disasters have increased the sensitivity of world-wide public opinion towards the effect that environmental pollution has on human health and climate change. These conditions have fostered a renewed interest in renewable energy like solar energy, wind energy, biomass and solid wastes. In addition, the disposal of municipal solid waste (MSW) has become a critical and costly problem. The traditional landfill method requires large amounts of land and contaminates air, water and soil. The increase in socio-economic condition during the past ten years has also significantly increased the amount of solid waste generated. There are around 1200 tons of municipal solid waste (MSW) generated daily, of which the combustibles namely plastics, paper and textile waste represent 28%, and with the present generation rate, the landfill will be filled by 2012. The study was, therefore, initiated to assess the potential of power generation from refused derived fuels (RDF) from municipal solid waste (MSW) in order to reduce the dependency on fossil fuels. There are 336 tons which is equivalent to 12 tons/ h of RDF that can be generated daily from the MSW and this would generate 19.2 MW power. There will be 312 kg/ h of ash that would be generated and the NO x and SO 2 concentration were found to be 395.5 and 43.3 mg/ Nm 3 respectively. It was also found that the amount of non-biogenic CO 2 produced was 471 g/ kWhe. (author)

  11. Nuclear Energy Cost Data Base: A reference data base for nuclear and coal-fired powerplant power generation cost analysis

    International Nuclear Information System (INIS)

    Delene, J.G.; Bowers, H.I.

    1986-12-01

    A reference data base and standard methodology are needed for performing comparative nuclear and fossil power generation cost analyses for the Department of Energy, Office of Nuclear Energy. This report contains such a methodology together with reference assumptions and data to be used with the methodology. It is intended to provide basic guidelines or a starting point for analyses and to serve as a focal point in establishing parameters and methods to be used in economic comparisons of nuclear systems with alternatives. The data base is applicable for economic comparisons of new base load light-water reactors on either the current once-through cycle or self-generated recycle, high- and low-sulfur coal-fired plants, and oil- and natural gas-fired electric generating plants coming on line around the turn of the century. In additions to light-water reactors and fossil fuel-fired plants, preliminary cost information is also presented on liquid metal reactor plants. This report includes a data base containing proposed technical and economic assumptions to be used in analyses, discussions of recommended methodology to be used in calculating power generation costs, and a sample calculation for illustrative benchmark purposes

  12. Nuclear Energy Cost Data Base: a reference data base for nuclear and coal-fired powerplant power generation cost analysis

    International Nuclear Information System (INIS)

    1985-06-01

    A reference data base and standard methodology are needed for performing comparative nuclear and fossil power generation cost analyses for the Department of Energy, Office of Nuclear Energy. This report contains such a methodology together with reference assumptions and data to be used with the methodology. It is intended to provide basic guidelines or a starting point for analyses and to serve as a focal point in establishing parameters and methods to be used in economic comparisons of nuclear systems with alternatives. The data base is applicable for economic comparisons of new base load light-water reactors on either the current once-through cycle or self-generated recycle, high- and low-sulfur coal-fired plants, and oil- and natural gas-fired electric generating plants coming on line in the last decade of this century. In addition to light-water reactors and fossil fuel-fired plants, preliminary cost information is also presented on liquid metal reactor plants. This report includes a data base containing proposed technical and economic assumptions to be used in analyses, discussions of a recommended methodology to be used in calculating power generation costs, and a sample calculation for illustrative and benchmark purposes

  13. Electronic firing systems and methods for firing a device

    Science.gov (United States)

    Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID

    2012-04-24

    An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.

  14. Medication Refusal: Resident Rights, Administration Dilemma.

    Science.gov (United States)

    Haskins, Danielle R; Wick, Jeannette Y

    2017-12-01

    Occasionally, residents actively or passively refuse to take medications. Residents may refuse medication for a number of reasons, including religious beliefs, dietary restrictions, misunderstandings, cognitive impairment, desire to self-harm, or simple inconvenience. This action creates a unique situation for pharmacists and long-term facility staff, especially if patients have dementia. Residents have the legal right to refuse medications, and long-term care facilities need to employ a process to resolve disagreement between the health care team that recommends the medication and the resident who refuses it. In some cases, simple interventions like selecting a different medication or scheduling medications in a different time can address and resolve the resident's objection. If the medical team and the resident cannot resolve their disagreement, often an ethics consultation is helpful. Documenting the resident's refusal to take any or all medications, the health care team's actions and any other outcomes are important. Residents' beliefs may change over time, and the health care team needs to be prepared to revisit the issue as necessary.

  15. Cubicle Refusal in Norwegian Dairy Herds

    Directory of Open Access Journals (Sweden)

    Myren HJ

    2001-03-01

    Full Text Available In order to survey the behaviour of choosing the alley area instead of a cubicle as a lying place (cubicle refusal, a questionnaire was sent to the 273 dairy farms in Norway known to keep cows in cubicle housing systems. Sixty-six percent of the farmers contacted were included in the study. The median herd size was 18 cows (range 7–118. More than 85% of the herds had sheds providing one or more cubicles per cow. The mean herd occurrence of cubicle refusal was 6%, but showed great variation (range 0–55%. Regression analysis showed a significant association between rearing heifers in slatted floor pens and an increased cubicle refusal occurrence (p = 0.02, R2 = 0.05, while herd size, use of litter, or cubicle-to-animal ratio were not found to be associated with cubicle refusal. The practice of rearing heifers in slatted floor pens accounted for about one half of the observed cubicle refusal (etiologic fraction = 0.51.

  16. Fire protection program evaluation of Argonne National Laboratory, West for the Department of Energy

    International Nuclear Information System (INIS)

    1984-01-01

    A fire protection engineering survey was conducted of the Argonne National Laboratory, West Facility, near Idaho Falls, Idaho. This facility includes EBR-II, TREAT, ZPPR, and HFEF. The facility meets the improved risk criteria as set forth in DOE Order 5480.1, Chapter VII. Some recommendations are given

  17. Current status of research on school refusal

    Directory of Open Access Journals (Sweden)

    Cándido J. Inglés

    2015-06-01

    Full Text Available School refusal behavior refers to the avoidance of a child attending school and/or persistent difficulty staying in the classroom throughout the school day. Based on a review of the scientific literature, the aim of this study is to describe the current state of research on school refusal, differentiating between the findings and progress made in Spain from those achieved in the international field. For this purpose, the significance of this phenomenon, in addition to associated risk factors and variables, will be reviewed in the child and youth population. In turn, the commonly used assessment methods and most recommended treatment proposals, mainly based on cognitive behavioral therapy, are discussed. The results reveal several gaps and subjects for debate in some areas of knowledge about school refusal behavior, with differences being found between Spanish and international studies. In conclusion, future studies and challenges in this field are required.

  18. Refusing The Choice: Balancing Life and Work

    Science.gov (United States)

    Brooks, J.

    2012-12-01

    The Choice The intellect of man is forced to choose perfection of the life, or of the work, And if it take the second must refuse A heavenly mansion, raging in the dark. When all that story's finished, what's the news? In luck or out the toil has left its mark: That old perplexity an empty purse, Or the day's vanity, the night's remorse. William Butler Yeats William Yeats put forward The Choice that I feel too many scientists feel they must make. Too often, many choose to leave science. How do we refuse this choice and find balance between life and our careers? While I don't know the answer, I will share choices that have lead to not perfection but satisfaction in science careers and lives. The role of mentors, supportive spouses, the luck of the job, and flexibility in research directions have all contributed to being able to refuse to choose.

  19. Coal fires, fresh air and the hardy British: A historical view of domestic energy efficiency and thermal comfort in Britain

    International Nuclear Information System (INIS)

    Rudge, Janet

    2012-01-01

    Fuel poverty has been most commonly researched in the UK although it is experienced in other parts of Europe, to varying degrees. showed that energy inefficient buildings and heating systems are the most significant components of fuel poverty and highlighted the legacy of older buildings in this country that remain the majority of those now recognised as hard to treat. This paper considers the historical context for fuel poverty as a particularly British phenomenon. It examines claims that this is due to the mild climate and low indoor temperature expectations. It is concluded that there are significant differences from the European situation. The climate, particularly its characteristic changeability, has influenced building and heating methods, and the low priority given to energy efficiency by legislators. Significantly, economic priorities produced poor quality mass housing during the industrial revolution. The availability of coal encouraged the use of open fires, which demanded high ventilation rates. The British do value warmth but older buildings designed for heating with radiant open fires are difficult to adapt to convective central heating. Lessons can be drawn for newly industrialised economies similarly producing poor quality mass housing with low priorities for energy efficiency. - Highlights: ► Historical reasons for fuel poverty as a particularly UK phenomenon are considered. ► There are significant differences with the European situation. ► The changeable climate influenced building and heating methods as well as health. ► Fuel supply encouraged heating by inefficient open fires that needed draughts. ► Improving airtightness in an oldhousing stock remains challenging.

  20. Energy consumption and energy-saving potential analysis of pollutant abatement systems in a 1000MW coal-fired power plant.

    Science.gov (United States)

    Yang, Hang; Zhang, Yongxin; Zheng, Chenghang; Wu, Xuecheng; Chen, Linghong; Gao, Xiang; Fu, Joshua S

    2018-05-10

    The pollutant abatement systems are widely applied in the coal-fired power sector and the energy consumption was considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000 MW coal-fired power unit which meet the ultra-low emission limits and the factors of operating parameters including unit load and inlet concentration of pollutants on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The WFGD system consumed 67% of the rate while the SCR and ESP systems consumed 8.9% and 24.1%. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of WFGD system. Implication Statement The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.

  1. The OECD FIRE database

    International Nuclear Information System (INIS)

    Angner, A.; Berg, H.P.; Roewekamp, M.; Werner, W.; Gauvain, J.

    2007-01-01

    Realistic modelling of fire scenarios is still difficult due to the scarcity of reliable data needed for deterministic and probabilistic fire safety analysis. Therefore, it has been recognized as highly important to establish a fire event database on an international level. In consequence, several member countries of the Nuclear Energy Agency of the OECD have decided in 2000 to establish the International Fire Data Exchange Project (OECD FIRE) to encourage multilateral co-operation in the collection and analysis of data related to fire events at nuclear power plants. This paper presents the OECD FIRE project objectives, work scope and current status of the OECD FIRE database after 3 years of operation as well as first preliminary statistical insights gained from the collected data. (orig.)

  2. Energy, exergy, environmental and economic analysis of industrial fired heaters based on heat recovery and preheating techniques

    International Nuclear Information System (INIS)

    Shekarchian, M.; Zarifi, F.; Moghavvemi, M.; Motasemi, F.; Mahlia, T.M.I.

    2013-01-01

    Highlights: • 4-E analysis of a typical industrial grade fired heater unit is studied. • This analysis is accomplished for the first time in this study. • Heat recovery and air preheating lead to substantial reduction in the fuel consumption. • The company’s current costs are tremendously reduced by these methods. • The methods lead to mitigation in GHG emission and to reduction in the associated taxes. - Abstract: Fired heaters are ubiquitous in both the petroleum and petrochemical industries, due to it being vital in their day to day operations. They form major components in petroleum refineries, petrochemical facilities, and processing units. This study was commissioned in order to analyze the economic benefits of incorporating both heat recovery and air preheating methods into the existing fired heater units. Four fired heater units were analyzed from the energy and environmental point of views. Moreover, the second law efficiency and the rate of irreversibility were also analyzed via the exergy analysis. Both analyses was indicative of the fact that the heat recovery process enhances both the first and second law efficiencies while simultaneously assisting in the production of high and low pressure water steam. The implementation and usage of the process improves the thermal and exergy efficiencies from 63.4% to 71.7% and 49.4%, to 54.8%, respectively. Additionally, the heat recovery and air preheating methods leads to a substantial reduction in fuel consumption, in the realm of up to 7.4%, while also simultaneously decreasing heat loss and the irreversibility of the unit. Nevertheless, the results of the economic analysis posits that although utilizing an air preheater unit enhances the thermal performance of the system, due to the air preheater’s capital and maintenance costs, incorporating an air preheater unit to an existing fired heater is not economically justifiable. Furthermore, the results of the sensitivity analysis and payback period

  3. 8. European sewage and refuse symposium. Documentation

    International Nuclear Information System (INIS)

    1990-01-01

    The subject of the 8. European Sewage and Refuse Symposium is covered under the following headings: collection and control in sewers, industrial waste water management, pretreatment, combined treatment, special cases, industrial waste water sludges disposal and the European waste business. (orig./BBR)

  4. [Professionals' training and refusal of nursing care].

    Science.gov (United States)

    Bay, Corinne

    2016-10-01

    A patient's refusal of nursing care concerns the caregivers. Future professionals must be prepared for it and student nurses are trained to deal with such situations. It is also important to empower patients and support them in their choice. This article presents the example of the Haute École Robert Schuman in Libramont, Belgium. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Analysis of fouling in refuse waste incinerators

    NARCIS (Netherlands)

    Beek, van M.C.; Rindt, C.C.M.; Wijers, J.G.; Steenhoven, van A.A.

    2001-01-01

    Gas-side fouling of waste-heat-recovery boilers, caused mainly by the deposition of particulate matter, reduces the heat transfer in the boiler. The fouling as observed on the tube bundles in the boiler of a Dutch refuse waste incinerator varied from thin and powdery for the economizer to thick and

  6. Fire Perimeters

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2003. Some fires...

  7. Fire History

    Data.gov (United States)

    California Natural Resource Agency — The Fire Perimeters data consists of CDF fires 300 acres and greater in size and USFS fires 10 acres and greater throughout California from 1950 to 2002. Some fires...

  8. Fire Protection Program Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  9. Integrating geothermal into coal-fired power plant with carbon capture: A comparative study with solar energy

    International Nuclear Information System (INIS)

    Wang, Fu; Deng, Shuai; Zhao, Jun; Zhao, Jiapei; Yang, Guohua; Yan, Jinyue

    2017-01-01

    Highlights: • Post-combustion carbon capture integrating geothermal energy was proposed. • A 300 MWe subcritical coal-fired plant was selected as the baseline. • The geothermal assisted carbon capture system was compared with solar assisted carbon capture plant. • Two different locations were chosen for the technical and economical comparison. • Using medium temperature geothermal thermal energy to replace steam extraction performs better performance. - Abstract: A new system integrating geothermal energy into post-combustion carbon capture is proposed in this paper. Geothermal energy at medium temperatures is used to provide the required thermal heat for solvent regeneration. The performance of this system is compared with solar assisted carbon capture plant via technical and economic evaluation. A 300 MWe coal-fired power plant is selected as the reference case, and two different locations based on the local climatic conditions and geothermal resources are chosen for the comparison. The results show that the geothermal assisted post-combustion carbon capture plant has better performances than the solar assisted one in term of the net power output and annual electricity generation. The net plant average efficiency based on lower heating value can be increased by 2.75% with a thermal load fraction of about 41%. Results of economic assessment show that the proposed geothermal assisted post-combustion carbon capture system has lower levelized costs of electricity and cost of carbon dioxide avoidance compared to the solar assisted post-combustion carbon capture plant. In order to achieve comparative advantages over the reference post-combustion carbon capture plant in both locations, the price of solar collector has to be lower than 70 USD/m 2 , and the drilling depth of the geothermal well shall be less than 2.1 km.

  10. Refurbishment priorities at the Russian coal-fired power sector for cleaner energy production case studies

    Energy Technology Data Exchange (ETDEWEB)

    P. Grammelis; N. Koukouzas; G. Skodras; E. Kakaras; A. Tumanovsky; V. Kotler [Centre for Research and Technology Hellas/Institute of Solid Fuels Technology and Applications (CERTH/ISFTA), Ptolemaida (Greece)

    2006-11-15

    The paper reviews the current status of the coal-fired power sector in Russia, the prospects for renovation activities based on Clean Coal Technologies (CCT) and presents two case studies on potential refurbishment projects. Data were collected for 180 thermoelectric units with capacity higher than 100 MWe and the renovation needs of the power sector, among the retrofitting, repowering and reconstruction options, were estimated through a multi-criteria analysis. The most attractive system to renovate a power plant between the Supercritical Combustion (SC) and the Fluidized Bed Combustion (FBC) technologies was evaluated. The application of each of the aforementioned technologies at the Kashirskaya and Shaturskaya power plants was studied and their replication potential in the Russian coal-fired power plant park was examined. Nowadays, the installed capacity of coal-fired power plants in the Russian Federation is 29.3 GWe, while they account for about 19% of the total electricity generation in the area. The low efficiency and especially the advanced age are the determinant factors for renovation applications at the Russian units. Even in the more conservative modernization scenario, over 30% of the thermoelectric units have to be repowered or reconstructed. Concrete proposals about the profitable and reliable operation of two Russian thermoelectric units with minimized environmental effects were elaborated. A new unit of 315 MWe with supercritical steam parameters and reburning for NOx abatement is envisaged to upgrade Unit 1 of Kashirskaya power station, while new circulating fluidized bed (CFB) boilers of the same steam generation is the most promising renovation option for the boilers of Unit 1 in Shaturskaya power station. 11 refs., 15 figs., 7 tabs.

  11. 30 CFR 77.214 - Refuse piles; general.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Refuse piles; general. 77.214 Section 77.214... Installations § 77.214 Refuse piles; general. (a) Refuse piles constructed on or after July 1, 1971, shall be..., tipples, or other surface installations and such piles shall not be located over abandoned openings or...

  12. 30 CFR 77.215-3 - Refuse piles: certification.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Refuse piles: certification. 77.215-3 Section... COAL MINES Surface Installations § 77.215-3 Refuse piles: certification. (a) Within 180 days following written notification by the District Manager that a refuse pile can present a hazard, the person owning...

  13. 30 CFR 77.215-1 - Refuse piles; identification.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Refuse piles; identification. 77.215-1 Section... COAL MINES Surface Installations § 77.215-1 Refuse piles; identification. A permanent identification marker, at least six feet high and showing the refuse pile identification number as assigned by the...

  14. 30 CFR 77.215-2 - Refuse piles; reporting requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Refuse piles; reporting requirements. 77.215-2... COAL MINES Surface Installations § 77.215-2 Refuse piles; reporting requirements. (a) The proposed location of a new refuse pile shall be reported to and acknowledged in writing by the District Manager...

  15. 30 CFR 77.215 - Refuse piles; construction requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Refuse piles; construction requirements. 77.215... COAL MINES Surface Installations § 77.215 Refuse piles; construction requirements. (a) Refuse deposited on a pile shall be spread in layers and compacted in such a manner so as to minimize the flow of air...

  16. 25 CFR 135.6 - Refusal of water delivery.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Refusal of water delivery. 135.6 Section 135.6 Indians... INDIAN IRRIGATION PROJECT Charges Assessed Against Irrigation District Lands § 135.6 Refusal of water delivery. The right is reserved to the United States to refuse the delivery of water to each of the said...

  17. Refusal Skill Ability: An Examination of Adolescent Perceptions of Effectiveness

    Science.gov (United States)

    Nichols, Tracy R.; Birnel, Sara; Graber, Julia A.; Brooks-Gunn, Jeanne; Botvin, Gilbert J.

    2010-01-01

    This pilot study examined whether refusal assertion as defined by a proven drug prevention program was associated with adolescent perceptions of effectiveness by comparing two sets of coded responses to adolescent videotaped refusal role-plays (N = 63). The original set of codes was defined by programmatic standards of refusal assertion and the…

  18. Persian Speakers' Use of Refusal Strategies across Politeness Systems

    Science.gov (United States)

    Salmani Nodoushan, Mohammad Ali

    2016-01-01

    This study aimed at investigating the preferred refusal strategies in Persian. 3047 refusals collected by 108 field workers as well as 376 refusals collected through face to face interviews were analyzed and classified according to the descriptions proposed by Liao (1994) and Liao and Bresnahan (1996). The frequencies of the resulting direct and…

  19. Primary care pediatricians' perceptions of vaccine refusal in europe.

    Science.gov (United States)

    Grossman, Zachi; van Esso, Diego; Del Torso, Stefano; Hadjipanayis, Adamos; Drabik, Anna; Gerber, Andreas; Miron, Dan

    2011-03-01

    An electronic survey assessing primary care pediatricians' estimations and practices regarding parents' vaccination refusal was sent to 395 members of the European Academy of Pediatrics Research in Ambulatory Setting network, with a response rate of 87%. Of respondents who vaccinate in the clinic, 93% estimated the total vaccine refusal rate as refusing parents.

  20. 21 CFR 211.50 - Sewage and refuse.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sewage and refuse. 211.50 Section 211.50 Food and... CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Buildings and Facilities § 211.50 Sewage and refuse. Sewage, trash, and other refuse in and from the building and immediate premises shall be...

  1. 25 CFR 135.23 - Refusal of water delivery.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Refusal of water delivery. 135.23 Section 135.23 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR FINANCIAL ACTIVITIES CONSTRUCTION ASSESSMENTS, CROW... District § 135.23 Refusal of water delivery. The right is reserved to refuse the delivery of water to any...

  2. 19 CFR 12.114 - Release or refusal of delivery.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Release or refusal of delivery. 12.114 Section 12... delivery. If the completed Notice of Arrival directs the port director to release the shipment of... directs the port director to refuse delivery of the shipment, the shipment shall be refused delivery and...

  3. Seasonal performance and energy costs of oil or gas-fired boilers and furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Berlad, A.L.; Lin, H.C.; Batey, J.; Salzano, F.J.; Yu, W.S.; Hoppe, R.J.; Allen, T.

    1977-03-01

    The seasonal operating cost of a small oil or gas-fired boiler or furnace depends upon the intrinsic merits of the device itself, the appropriateness of its capacity and cycle characteristics to the imposed load conditions, the weather characteristics and heat loss characteristics of the building being heated, and the control philosophy employed. The current study provides the bases for comparing quantitatively the seasonal operating costs of various specific space heating and/or domestic hot water systems, as influenced by the device specifics and device interaction with the space conditioned system that it serves. The resulting formalism is applied to various space-heating systems. Quantitative cost comparisons are presented.

  4. A preliminary evaluation of a combined tire- and refuse-derived fuel (TDF-RDF)

    Energy Technology Data Exchange (ETDEWEB)

    Stessel, R.I.; Amari, T.; Themelis, N.J.; Wearnick, I.K.

    1999-07-01

    In dense urban areas of the US, it is now becoming clear that waste management is far from economically-optimum. Even with the popularity of inexpensive land disposal, hauling and recycling costs are driving up the average waste bill. An historic option has been refuse-derived fuel, or RDF. Difficulties included low energy content and difficulty obtaining uniformity. Today, many resource-recovery technologies used in RDF are finding their way into materials recovery facilities (MRFs), some of which are reviving the automated processing of waste. Any MRF, automated or not, will have residue streams. Currently, one of the most significant problems is waste tires. Local options are difficult to locate in dense urban areas. As fuels, tires typically have energy contents considerably above those for which most solid-fuel combustors are designed, leading to thermal imbalances and various forms of failure. This paper suggests a new fuel that can be either co-fired with coal, or used in its own right in a combustor primarily designed for coal: TDF-RDF. A preliminary examination is undertaken of thermal and emissions characteristics, and possible costs for a few applications of the fuel. Immediately, TDF is already cleaner-burning than many coals, even in sulfur emissions. RDF has been widely-regarded as being similarly cleanly. Posited MRF residue streams should be still cleaner, and more consistent, than RDF. Overall, there is quite a potential for developing a fuel that would allow old coal powerplants in historic urban centers to be better neighbors, while helping with a few problems in municipal waste management.

  5. Energy utilisation of biowaste - Sunflower-seed hulls for co-firing with coal

    Energy Technology Data Exchange (ETDEWEB)

    Raclavska, Helena; Juchelkova, Dagmar; Roubicek, Vaclav; Matysek, Dalibor [VSB-Technical University of Ostrava, 17. listopadu 15, CZ-70833 Ostrava (Czech Republic)

    2011-01-15

    Sunflower-seed hulls (SSH) represent a source of combustible biomass characterised by high contents of potassium and phosphorus and a low silica content. The relatively high net calorific value of 20 MJ/kg d.m. is mainly influenced by the lignin content. Potassium and phosphorus are very important elements in biomass combustion for fuel, influencing slagging and fouling problems. Mixtures with different ratios of brown coal and sunflower-seed hulls (0-22% SSH) were co-fired in the Olomouc power plant. The behaviour of elements in the fly ash and the bottom ash (SiO{sub 2}, Al{sub 2}O{sub 3}, K{sub 2}O, P{sub 2}O{sub 5}, Zn, Cu and Cd) varied in relation to the amount of SSH added to the coal. The fly ash from the co-firing of 20% SSH with coal had a high content of water-leachable sulphates and total dissolved solids. The utilisation of fly ash in civil engineering (land reclamation) should fulfil criteria established by the Council Decision 2003/33/EC for non-hazardous waste. To ensure that the required water-leachable sulphate concentrations are within regulatory limits the fuel may contain a maximum of 14% SSH. (author)

  6. Energy-saving and emission-abatement potential of Chinese coal-fired power enterprise: A non-parametric analysis

    International Nuclear Information System (INIS)

    Wei, Chu; Löschel, Andreas; Liu, Bing

    2015-01-01

    In the context of soaring demand for electricity, mitigating and controlling greenhouse gas emissions is a great challenge for China's power sector. Increasing attention has been placed on the evaluation of energy efficiency and CO 2 abatement potential in the power sector. However, studies at the micro-level are relatively rare due to serious data limitations. This study uses the 2004 and 2008 Census data of Zhejiang province to construct a non-parametric frontier in order to assess the abatement space of energy and associated CO 2 emission from China's coal-fired power enterprises. A Weighted Russell Directional Distance Function (WRDDF) is applied to construct an energy-saving potential index and a CO 2 emission-abatement potential index. Both indicators depict the inefficiency level in terms of energy utilization and CO 2 emissions of electric power plants. Our results show a substantial variation of energy-saving potential and CO 2 abatement potential among enterprises. We find that large power enterprises are less efficient in 2004, but become more efficient than smaller enterprises in 2008. State-owned enterprises (SOE) are not significantly different in 2008 from 2004, but perform better than their non-SOE counterparts in 2008. This change in performance for large enterprises and SOE might be driven by the “top-1000 Enterprise Energy Conservation Action” that was implemented in 2006. - Highlights: • Energy-saving potential and CO 2 abatement-potential for Chinese power enterprise are evaluated. • The potential to curb energy and emission shows great variation and dynamic changes. • Large enterprise is less efficient than small enterprise in 2004, but more efficient in 2008. • The state-owned enterprise performs better than non-state-owned enterprise in 2008

  7. Wind, Water, Fire, and Earth. Energy Lessons for the Physical Sciences.

    Science.gov (United States)

    Watt, Shirley L., Ed.; And Others

    The current energy situation in the United States is a web of complicated and related elements. This document attempts to address some of these variables in presenting interdisciplinary energy lessons taken from instructional packets previously developed by the Project for an Energy-Enriched Curriculum (PEEC). The 19 physical science lessons…

  8. Use for refuse of shale carbonization

    Energy Technology Data Exchange (ETDEWEB)

    1917-09-25

    A process is disclosed for using the refuse from the carbonization of bituminous shales in the preparation of light building material, characterized in that the pulverized material is mixed wet with a light filler, formed in a mold, and burned with or without the addition of clay or with the addition of binding and preserving material, preparing the mold from the pulverized material in the cold.

  9. Biomass direct-fired power generation system in China: An integrated energy, GHG emissions, and economic evaluation for Salix

    International Nuclear Information System (INIS)

    Wang, Changbo; Zhang, Lixiao; Chang, Yuan; Pang, Mingyue

    2015-01-01

    To gain a better understanding of the options of biomass power generation in China, this study presented an integrated energy, environmental, and economic evaluation for Salix in China, and a typical Salix direct-fired power generation system (SDPGS) in Inner Mongolia was selected for case study. A tiered hybrid life cycle assessment (LCA) model was developed to calculate the “planting-to-wire” (PTW) energy consumption, greenhouse gas (GHG) emissions, and economic cost and profit of the SDPGS, including feedstock cultivation, power plant construction and operation, and on-grid price with/without government subsidies. The results show that the PTW energy consumption and GHG emissions of Salix are 0.8 MJ/kWh and 114 g CO 2 -eq/kWh, respectively, indicating an energy payback time (EPBT) of 3.2 years. The SDPGS is not economically feasible without government subsidies. The PTW costs are dominated by feedstock cultivation. The energy saving and GHG mitigation benefits are still robust, even when the power plant runs at only 60% design capacity. For future development of biomass power in China, scientific planning is necessary to guarantee a sufficient feedstock supply. In addition, technology progress, mature industrial chains, and reasonable price setting policy are required to enable potential energy and environmental advantages of biomass power moving forward. -- Highlights: •A hybrid LCA model was used to evaluate overall performance of the SDPGS. •On-site processes dominate the “planting-to-wire” footprints. •The energy saving and GHG mitigation benefits of the SDPGS are robust. •The economic profit of the SDPGS is feeble without government subsidies. •Generating efficiency promotion has a comprehensive positive effect on the system

  10. Microbial ecology of coal mine refuse

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, R. E.; Miller, R. M.

    1977-01-01

    Baseline microbial and ecological studies of samples obtained from two abandoned coal mine refuse sites in the State of Illinois indicate that the unfavorable nature of refuse materials can be a very limiting factor for survival and growth of organisms. Despite the ''foothold'' obtained by some microorganisms, especially acidophilic fungi and some acidotolerant algae, the refuse materials should be amended or ameliorated to raise the pH, provide needed nutrients, especially nitrogen, and provide biodegradable organic matter, both for physical and biological purposes. Finally, the role of microbial populations, responses, and interactions in acid mine wastes must be put into larger perspective. Acid mine drainage amounts to over 4 million tons per year of acidity from active and abandoned mines. Microorganisms appear to be significantly responsible for this problem, but they also can play a beneficial and significant role in the amelioration or alleviation of this detrimental effect as abandoned mines are reclaimed and returned to useful productivity.

  11. Geomorphic reclmation of a coal refuse pile

    Science.gov (United States)

    Hopkinson, L. C.; Quaranta, J.

    2017-12-01

    Geomorphic reclamation is a technique that may offer opportunities to improve mine reclamation in Central Appalachia. The design approach is based on constructing a steady-state, mature landform condition and takes into account the long-term climatic conditions, soil types, terrain grade, and vegetation. Geomorphic reclamation has been applied successfully in semi-arid regions but has not yet been applied in Central Appalachia. This work describes a demonstration study where geomorphic landforming techniques are being applied to a coarse coal refuse pile in southern West Virginia, USA. The reclamation design includes four geomorphic watersheds that radially drain runoff from the pile. Each watershed has one central draining channel and incorporates compound slope profiles similarly to naturally eroded slopes. Planar slopes were also included to maintain the impacted area. The intent is to alter the hydrology to decrease water quality treatment costs. The excavation cut and fill volumes are comparable to those of more conventional refuse pile reclamation designs. If proven successful then this technique can be part of a cost-effective solution to improve water quality at active and future refuse facilities, abandoned mine lands, bond forfeiture sites, landfills, and major earthmoving activities within the region.

  12. A comparative study of health hazards and environmental impacts for electricity generation through nuclear energy hidroelectricity and coal fired thermoeletrical generation

    International Nuclear Information System (INIS)

    Guimaraes, C.A.

    1982-01-01

    Environmental impacts and health hazards were comparatively assessed in regard to electricity generation via nuclear energy, hidraulic dams and coal firing. The main aspects covered the nuclear reactor and its associated nuclear fuel cycle, coal fired thermoelectrical power plant its associated coal industry, and hidroelectrical power plant and its dam. Besides specific comparisons of impacts in the air, water, soil and health hazards an evaluation for the Brazilian case was made based on a forecast of electricity demand up to the year 2020. For the nuclear option the consequences were analysed based on American data since no data is yet available for Brazil. Coal firing option was also analised for based heavily on American data due to small Brazilian experience in this sector of energy generation. For hydroelectrical option Brazilian data were used mostly from CESP for comparative purposes. These alternatives for generation of electricity considered in this study are the most relevant for the next four decades for Brazil. (Author) [pt

  13. Biomass co-firing

    DEFF Research Database (Denmark)

    Yin, Chungen

    2013-01-01

    Co-firing biomass with fossil fuels in existing power plants is an attractive option for significantly increasing renewable energy resource utilization and reducing CO2 emissions. This chapter mainly discusses three direct co-firing technologies: pulverized-fuel (PF) boilers, fluidized-bed combus......Co-firing biomass with fossil fuels in existing power plants is an attractive option for significantly increasing renewable energy resource utilization and reducing CO2 emissions. This chapter mainly discusses three direct co-firing technologies: pulverized-fuel (PF) boilers, fluidized......-bed combustion (FBC) systems, and grate-firing systems, which are employed in about 50%, 40% and 10% of all the co-firing plants, respectively. Their basic principles, process technologies, advantages, and limitations are presented, followed by a brief comparison of these technologies when applied to biomass co...

  14. A novel solar energy integrated low-rank coal fired power generation using coal pre-drying and an absorption heat pump

    International Nuclear Information System (INIS)

    Xu, Cheng; Bai, Pu; Xin, Tuantuan; Hu, Yue; Xu, Gang; Yang, Yongping

    2017-01-01

    Highlights: •An improved solar energy integrated LRC fired power generation is proposed. •High efficient and economic feasible solar energy conversion is achieved. •Cold-end losses of the boiler and condenser are reduced. •The energy and exergy efficiencies of the overall system are improved. -- Abstract: A novel solar energy integrated low-rank coal (LRC) fired power generation using coal pre-drying and an absorption heat pump (AHP) was proposed. The proposed integrated system efficiently utilizes the solar energy collected from the parabolic trough to drive the AHP to absorb the low-grade waste heat of the steam cycle, achieving larger amount of heat with suitable temperature for coal’s moisture removal prior to the furnace. Through employing the proposed system, the solar energy could be partially converted into the high-grade coal’s heating value and the cold-end losses of the boiler and the steam cycle could be reduced simultaneously, leading to a high-efficient solar energy conversion together with a preferable overall thermal efficiency of the power generation. The results of the detailed thermodynamic and economic analyses showed that, using the proposed integrated concept in a typical 600 MW LRC-fired power plant could reduce the raw coal consumption by 4.6 kg/s with overall energy and exergy efficiencies improvement of 1.2 and 1.8 percentage points, respectively, as 73.0 MW th solar thermal energy was introduced. The cost of the solar generated electric power could be as low as $0.044/kW h. This work provides an improved concept to further advance the solar energy conversion and utilisation in solar-hybrid coal-fired power generation.

  15. Wildland Fire Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schwager, K. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-09-30

    The Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) is written to comply with Department of Energy (DOE) Integrated Safety Management Policy; Federal Wildland Fire Management Policy and Program Review; and Wildland and Prescribed Fire Management Policy and Implementation Procedures Reference Guide. This current plan incorporates changes resulting from new policies on the national level as well as significant changes to available resources and other emerging issues, and replaces BNL's Wildland FMP dated 2014.

  16. Jointly optimizing selection of fuel treatments and siting of forest biomass-based energy production facilities for landscape-scale fire hazard reduction.

    Science.gov (United States)

    Peter J. Daugherty; Jeremy S. Fried

    2007-01-01

    Landscape-scale fuel treatments for forest fire hazard reduction potentially produce large quantities of material suitable for biomass energy production. The analytic framework FIA BioSum addresses this situation by developing detailed data on forest conditions and production under alternative fuel treatment prescriptions, and computes haul costs to alternative sites...

  17. The effects of variable renewable electricity on energy efficiency and full load hours of fossil-fired power plants in the European Union

    NARCIS (Netherlands)

    de Groot, Mats; Crijns-Graus, Wina; Harmsen, Robert

    2017-01-01

    This study focused on the effects of variable renewable electricity (VRE) on full load hours and energy efficiency of fossil-fired power generation in the European Union from 1990-2014. Member states were aggregated into three groups based on the level of VRE penetration. Average full load hours are

  18. Fluidized bed combustion of refuse-derived fuel in presence of protective coal ash

    Energy Technology Data Exchange (ETDEWEB)

    Ferrer, Eduardo [CIRCE, Universidad de Zaragoza, Maria de Luna, 3, Zaragoza (Spain); Aho, Martti [VTT Processes, P.O. Box 1603, 40101 Jyvaeskylae (Finland); Silvennoinen, Jaani; Nurminen, Riku-Ville [Kvaerner Power, P.O.Box 109, FIN-33101 Tampere (Finland)

    2005-12-15

    Combustion of refuse-derived fuel (RDF) alone or together with other biomass leads to superheater fouling and corrosion in efficient power plants (with high steam values) due to vaporization and condensation of alkali chlorides. In this study, means were found to raise the portion of RDF to 40% enb without risk to boilers. This was done by co-firing RDF with coal and optimizing coal quality. Free aluminum silicate in coal captured alkalies from vaporized alkali chlorides preventing Cl condensation to superheaters. Strong fouling and corrosion were simultaneously averted. Results from 100 kW and 4 MW CFB reactors are reported. (author)

  19. Vaccine refusal - what we need to know.

    Science.gov (United States)

    Succi, Regina Célia de Menezes

    2018-04-12

    Opposition to vaccines is not a new event, and appeared soon after the introduction of the smallpox vaccine in the late 18th century. The purpose of this review is to educate healthcare professionals about vaccine hesitancy and refusal, its causes and consequences, and make suggestions to address this challenge. A comprehensive and non-systematic search was carried out in the PubMed, LILACS, and ScieLo databases from 1980 to the present day, using the terms "vaccine refusal," "vaccine hesitancy," and "vaccine confidence." The publications considered as the most relevant by the author were critically selected. The beliefs and arguments of the anti-vaccine movements have remained unchanged in the past two centuries, but new social media has facilitated the dissemination of information against vaccines. Studies on the subject have intensified after 2010, but the author did not retrieve any published studies to quantify this behavior in Brazil. The nomenclature on the subject (vaccine hesitancy) was standardized by the World Health Organization in 2012. Discussions have been carried out on the possible causes of vaccine hesitancy and refusal, as well as on the behavior of families and health professionals. Proposals for interventions to decrease public doubts, clarify myths, and improve confidence in vaccines have been made. Guides for the health care professional to face the problem are emerging. The healthcare professional is a key element to transmit information, resolve doubts and increase confidence in vaccines. They must be prepared to face this new challenge. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  20. Environmental co-benefits of energy efficiency improvement in coal-fired power sector: A case study of Henan Province, China

    International Nuclear Information System (INIS)

    Wang, Ke; Wang, Shanshan; Liu, Lei; Yue, Hui; Zhang, Ruiqin; Tang, Xiaoyan

    2016-01-01

    Highlights: • Pollutant surcharge is considered in Energy Conservation Supply Curve. • Intake Fraction method is incorporated into Energy Conservation Supply Curve. • Health benefits contribute 97% of co-benefits of energy efficiency improvement. - Abstract: The coal-fired power sector is one of the major contributors to environmental problems and has great potential of air pollution abatement. This study employs Energy Conservation Supply Curves (ECSCs) combined with pollutant surcharge and health benefits to evaluate the environmental co-benefits of energy efficiency improvement in the coal-fired power sector. Health benefits and the pollution surcharge are considered as the environmental co-benefits that reduce costs of conserved energy (CCEs) in ECSCs. The health benefits of energy efficiency improvement are quantified using Intake Fraction method, while the pollutant surcharge is calculated based on the regulation. Three scenarios including a Business As Usual (BAU) scenario, an Energy Efficiency Improvement (EEI) scenario, and an Upgrading Standards and Incentive (USI) scenario is considered in a case study for Henan Province of China. Our results show that costs of conserved energy (CCEs) are reduced by 0.56 and 0.29 USD/GJ under the EEI and USI scenarios due to health benefits and pollutant surcharge reductions related to energy efficient technologies, respectively. In particular, health benefits account for 97% of the reductions in CCEs, while the pollutant surcharge only contributes 3%. Under the EEI and USI scenarios, in 2020, energy efficiency improvement reduces energy consumption in Henan’s coal-fired power sector by 3.3% and 3.5% compared with the BAU scenario, respectively. The EEI and USI scenarios indicates that health benefits of 1.5 × 10"9 and 2.4 × 10"9 USD are gained and the reductions of pollutant surcharges of 197 and 226 million USD are realized in 2020, respectively.

  1. Conscientious refusals and reason-giving.

    Science.gov (United States)

    Marsh, Jason

    2014-07-01

    Some philosophers have argued for what I call the reason-giving requirement for conscientious refusal in reproductive healthcare. According to this requirement, healthcare practitioners who conscientiously object to administering standard forms of treatment must have arguments to back up their conscience, arguments that are purely public in character. I argue that such a requirement, though attractive in some ways, faces an overlooked epistemic problem: it is either too easy or too difficult to satisfy in standard cases. I close by briefly considering whether a version of the reason-giving requirement can be salvaged despite this important difficulty. © 2013 John Wiley & Sons Ltd.

  2. Utilization of washery dirt and mine refuse

    Energy Technology Data Exchange (ETDEWEB)

    Leininger, D; Schieder, T

    1975-10-02

    Washery dirt and mine refuse may be used without processing as road ballast, embankments and dykes, and for filling gravel pits and subsidence areas. The properties required in road ballast are outlined. For the top portions of embankments and for frost protection layers, washery dirt must be processed to remove particles of the wrong size. Methods of heat treatment are listed, and the chemical composition of the dirt is discussed. Because of its different chemical composition, large particles are preferable to fine dirt for some applications, even if they have to be crushed. Tree planting experiments on spoilbanks are described.

  3. The Atomic Energy Control Board criteria for identification and evaluation of fire hazards in nuclear power stations

    International Nuclear Information System (INIS)

    Morrison, Luke

    1986-03-01

    This report presents criteria for the identification and evaluation of fire hazards in nuclear power stations. The report presents criteria that are consistent with the existing regulatory approach in Canada, and outlines engineering tools and analytical techniques currently available to deterministically analyse fire. The criteria presented cover the topics which should be included in a fire hazard analysis and provide details of each topic so that the accuracy of an analysis may be evaluated

  4. The Atomic Energy Control Board criteria for identification and evaluation of fire hazards in nuclear power stations

    International Nuclear Information System (INIS)

    Morrison, L.

    1986-03-01

    This report presents information for the identification and evaluation of fire hazards in nuclear power stations. The report consists of two volumes. Volume 1 contains background material which outlines tools and analytical techniques currently available to deterministically analyse fire hazards. Volume 2 presents criteria for evaluating fire hazard reports. The criteria are consistent with the existing AECB regulatory approach in Canada and cover the topics which should be included in a fire hazard analysis. This volume also provides details of each topic so that the quality of an analysis may be evaluated

  5. Differences between "refusers" and "non-refusers" in a psychological study.

    NARCIS (Netherlands)

    Hoogstraten, J.; Vorst, H.C.M.

    1972-01-01

    Administered the ABV (Amsterdam Biographical Questionnaire) and the LOS (Leadership Concept Scale) to 98 students. The directions indicated that the Ss need not comply with the requirement to complete the LOS. 21 Ss failed to avail themselves of this permission and were labeled "refusers" (A). Their

  6. Autonomy, religious values, and refusal of lifesaving medical treatment.

    OpenAIRE

    Wreen, M J

    1991-01-01

    The principal question of this paper is: Why are religious values special in refusal of lifesaving medical treatment? This question is approached through a critical examination of a common kind of refusal of treatment case, one involving a rational adult. The central value cited in defence of honouring such a patient's refusal is autonomy. Once autonomy is isolated from other justificatory factors, however, possible cases can be imagined which cast doubt on the great valuational weight assign...

  7. Energy, environmental and operation aspects of a SRF-fired fluidized bed waste-to-energy plant.

    Science.gov (United States)

    De Gisi, Sabino; Chiarelli, Agnese; Tagliente, Luca; Notarnicola, Michele

    2018-03-01

    A methodology based on the ISO 14031:2013 guideline has been developed and applied to a full-scale fluidized bed waste to energy plant (WtE) burning solid recovered fuel (SRF). With reference to 3years of operation, the data on energy and environmental performance, on raw materials consumptions such as sand and diesel fuel, accidental reasons of plant shutdown, have been acquired and analyzed. The obtained results have allowed to quantify the energy and environmental performance of the WtE plant under investigation by varying the amount and mixings of the inlet waste, available in form of thickened and fluff (similar to coriander) SRF. In terms of the energy performance, the fluidized bed technology applied to the SRF was able to guarantee an adequate production of electricity (satisfying the market demands), showing a relative flexibility with respect to the inlet waste. In terms of net energy production efficiency, the plant showed values in the range of 13.8-14.9% in line with similar installations. In terms of the environmental performance, the adoption of a cleaning system based on SNCR (Selective Non Catalitic Reduction)+semi-dry scrubbing+Fabric filter generated emissions usually well below the limits set by the EU Directive 2000/76/EC as well as the Italian Law 46/2014 (more restrictive) with reference to all the key parameters. In terms of the plant shutdown, the majority of problems focused on the combustion chamber and boiler due to the erosion of the refractory material of the furnace as well as to the breaking of the superheaters of the boiler. In contrast, the mechanical and electrical causes, along with those related to the control and instrumentation system, were of secondary importance. The sand bed de-fluidization was also among the leading causes of a frequent plant shutdown. In particular, results showed how although the SRF presents standard characteristics, the use of different mixtures may affect the number of plant shutdowns. The full

  8. Marketization of refuse collection in Denmark

    DEFF Research Database (Denmark)

    Busck, Ole Gunni

    2006-01-01

      Danish municipalities' outsourcing and contracting of refuse collection are framed by a complex set of ideologies and objectives, besides regulation. Both at EU-level and at national level extreme demands for marketization of the public sector are counter-weighed by demands for social and envir......  Danish municipalities' outsourcing and contracting of refuse collection are framed by a complex set of ideologies and objectives, besides regulation. Both at EU-level and at national level extreme demands for marketization of the public sector are counter-weighed by demands for social...... and environmental considerations associated with the superior goal of sustainable development. In the EU regulative complex developments in normative and legal regulation of social and environmental requirements to member-states' performance have co-existed with tough requirements to ensure open competition...... in public authorities contracting. In the latest edition of the procurement directive it has been clarified that public authorities' commitment of private service-providers to social and environmental requirements by contracting is perfectly legitimate. At national level the municipalities when contracting...

  9. Refusal to pay electricity bill is illegal

    International Nuclear Information System (INIS)

    Hermann, H.P.

    1979-01-01

    Pursuant to a judgement passed by the Lower Court of Hamburg, the author discusses probable legal arguments justifying the refusal to pay one's electricity bill, the so-called electricity bill boycott. Following an analysis of the power supply contract and of the content and the limits of the fundamental right of freedom of conscience, as well as of the concept of free enterprise and of the legal effect of licenses under the nuclear law, his point of view stated in the article is to agree with the decision of the court saying that the operation of a nuclear power plant licensed under the nuclear law does not mean an infringement of the right of freedom of conscience. It can further not be accepted to let people refuse to pay their electricity bill by referring to the right of freedom of speech, by alleging conduct against public policy on the part of the public utilities, or by referring to the right of opposition. (HSCH) [de

  10. Summoning earth and fire: The energy development implications of Grameen Shakti (GS) in Bangladesh

    International Nuclear Information System (INIS)

    Sovacool, Benjamin K.; Drupady, Ira Martina

    2011-01-01

    Since its establishment in 1996, the nonprofit company Grameen Shakti (GS) has installed almost half a million solar home systems (SHS), 132,000 cookstoves, and 13,300 biogas plants among 3.1 million beneficiaries. They plan to ramp up their expansion so that by 2015, more than 1.5 million SHS are in place along with 100,000 biogas units and 5 million improved cookstoves. This article describes GS's current activities, the contours of its programs, and likely reasons for its success. It also explores the remaining challenges facing GS and distils common lessons for other energy development assistance projects and programs around the world. After detailing research methods consisting primarily of research interviews and site visits, the article briefly explores the history of GS and summarizes its three most prominent programs. The article then identifies six distinct benefits to their programs-expansion of energy access, less deforestation and fewer greenhouse gas emissions, price savings, direct employment and income generation, improved public health, and better technology-before discussing challenges related to staff retention and organizational growth, living standards, technical obstacles, affordability, tension with other energy programs, political constraints, and awareness and cultural values. -- Highlights: → Grameen Shakti (GS) has installed a large number of solar home systems (SHS), cookstoves, and biogas plants. → GS programs have brought a wide array of social and economic benefits. → GS programs face internal and external challenges if they are to remain successful.

  11. Study of the fire behavior of high-energy lithium-ion batteries with full-scale burning test

    Science.gov (United States)

    Ping, Ping; Wang, QingSong; Huang, PeiFeng; Li, Ke; Sun, JinHua; Kong, DePeng; Chen, ChunHua

    2015-07-01

    A full-scale burning test is conducted to evaluate the safety of large-size and high-energy 50 Ah lithium-iron phosphate/graphite battery pack, which is composed of five 10 Ah single cells. The complex fire hazards associated with the combustion process of the battery are presented. The battery combustion behavior can be summarized into the following stages: battery expansion, jet flame, stable combustion, a second cycle of a jet flame followed by stable combustion, a third cycle of a jet flame followed by stable combustion, abatement and extinguishment. The multiple jets of flame indicate serious consequences for the battery and pose a challenge for battery safety. The battery ignites when the battery temperature reaches approximately 175-180 °C. This critical temperature is related to an internal short circuit of the battery, which results from the melting of the separator. The maximum temperature of the flame can reach 1500 °C. The heat release rate (HRR) varies based on the oxygen generated by the battery and the Joule effect of the internal short circuit. The HRR and heat of combustion can reach 49.4 kW and 18,195.1 kJ, respectively. The state of charge of the battery has a significant effect on the maximum HRR, the overall heat generation and the mass loss of the battery.

  12. X-Ray diffraction and scanning electron microscopy-energy dispersive spectroscopic analysis of ceramõmetal interface at different firing temperatures

    Directory of Open Access Journals (Sweden)

    Monika Saini

    2010-01-01

    Full Text Available Objective: Porcelain chipping from porcelain fused to metal restoration has been Achilles heel till date. There has been advent of newer ceramics in past but but none of them has been a panacea for Porcelain fracture. An optimal firing is thus essential for the clinical success of the porcelain-fused to metal restoration. The aim of the present study was to evaluate ceramo-metal interface at different firing temperature using XRD and SEM-EDS analysis. Clinical implication of the study was to predict the optimal firing temperature at which porcelain should be fused with metal in order to possibly prevent the occasional failure of the porcelain fused to metal restorations. Materials and Methods: To meet the above-mentioned goal, porcelain was fused to metal at different firing temperatures (930-990°C in vacuum. The microstructural observations of interface between porcelain and metal were evaluated using X-ray diffraction and scanning electron microscopy with energy dispersive spectroscopy. Results: Based on the experimental investigation of the interaction zone of porcelain fused to metal samples, it was observed that as the firing temperature was increased, the pores became less in number as well as the size of the pores decreased at the porcelain/metal interface upto 975°C but increased in size at 990°C. The least number of pores with least diameter were found in samples fired at 975°C. Several oxides like Cr 2 O 3 , NiO, and Al 2 O 3 and intermetallic compounds (CrSi 2 , AlNi 3 were also formed in the interaction zone. Conclusions : It is suggested that the presence of pores may trigger the crack propagation along the interface, causing the failure of the porcelain fused to metal restoration during masticatory action.

  13. An investigation on the fuel savings potential of hybrid hydraulic refuse collection vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Frank A., E-mail: bender@isys.uni-stuttgart.de; Bosse, Thomas; Sawodny, Oliver

    2014-09-15

    Highlights: • Driving cycle acquisition in a refuse collection vehicle. • Vehicle modeling and validation for numerical simulations based on the measured driving cycle. • Fuel consumption analysis for a conventional diesel vehicle and a hybrid hydraulic vehicle. - Abstract: Refuse trucks play an important role in the waste collection process. Due to their typical driving cycle, these vehicles are characterized by large fuel consumption, which strongly affects the overall waste disposal costs. Hybrid hydraulic refuse vehicles offer an interesting alternative to conventional diesel trucks, because they are able to recuperate, store and reuse braking energy. However, the expected fuel savings can vary strongly depending on the driving cycle and the operational mode. Therefore, in order to assess the possible fuel savings, a typical driving cycle was measured in a conventional vehicle run by the waste authority of the City of Stuttgart, and a dynamical model of the considered vehicle was built up. Based on the measured driving cycle and the vehicle model including the hybrid powertrain components, simulations for both the conventional and the hybrid vehicle were performed. Fuel consumption results that indicate savings of about 20% are presented and analyzed in order to evaluate the benefit of hybrid hydraulic vehicles used for refuse collection.

  14. An investigation on the fuel savings potential of hybrid hydraulic refuse collection vehicles

    International Nuclear Information System (INIS)

    Bender, Frank A.; Bosse, Thomas; Sawodny, Oliver

    2014-01-01

    Highlights: • Driving cycle acquisition in a refuse collection vehicle. • Vehicle modeling and validation for numerical simulations based on the measured driving cycle. • Fuel consumption analysis for a conventional diesel vehicle and a hybrid hydraulic vehicle. - Abstract: Refuse trucks play an important role in the waste collection process. Due to their typical driving cycle, these vehicles are characterized by large fuel consumption, which strongly affects the overall waste disposal costs. Hybrid hydraulic refuse vehicles offer an interesting alternative to conventional diesel trucks, because they are able to recuperate, store and reuse braking energy. However, the expected fuel savings can vary strongly depending on the driving cycle and the operational mode. Therefore, in order to assess the possible fuel savings, a typical driving cycle was measured in a conventional vehicle run by the waste authority of the City of Stuttgart, and a dynamical model of the considered vehicle was built up. Based on the measured driving cycle and the vehicle model including the hybrid powertrain components, simulations for both the conventional and the hybrid vehicle were performed. Fuel consumption results that indicate savings of about 20% are presented and analyzed in order to evaluate the benefit of hybrid hydraulic vehicles used for refuse collection

  15. Hospital wastes management containing in radioactive refusals

    International Nuclear Information System (INIS)

    Campi, F.

    1999-01-01

    In large hospitals, featuring a nuclear medicine department, diagnostic examinations and metabolic therapies are performed using an amount of radio drugs per day averaging around some hundreds mCi. Part of these drugs are disposed in the conventional patient related waste and collected within the hospital itself. Before directing the wastes to the disposal, it is necessary verify that they do not contain radioactive materials. This article refers a study on the possibility to perform this verification by means of an automatic radio-metric system, in order to improve the efficiency, the speed and the safety of the control. Measures devoted to determined the minimum detectable activities for the main radionuclides used in the hospitals have been executed, and it has been designed a comprehensive device able to operate automatically, and unattended by any operator, the selection of radioactive refusals [it

  16. 14 CFR 121.586 - Authority to refuse transportation.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Authority to refuse transportation. 121.586 Section 121.586 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... transportation. (a) No certificate holder may refuse transportation to a passenger on the basis that, because the...

  17. School Refusal: Assessment and Intervention within School Settings.

    Science.gov (United States)

    Wimmer, Mary B.

    Anxiety-based school refusal occurs in 2% of school-age children. The reasons why they refuse to go school range from mental illness and learning problems to general defiance and a desire for attention. Early identification and multi-faceted assessment and interventions are critical to addressing the problem. This book offers concise, practical…

  18. 36 CFR 1002.14 - Sanitation and refuse.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Sanitation and refuse. 1002.14 Section 1002.14 Parks, Forests, and Public Property PRESIDIO TRUST RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 1002.14 Sanitation and refuse. (a) The following are prohibited: (1) Disposing of...

  19. 36 CFR 2.14 - Sanitation and refuse.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Sanitation and refuse. 2.14 Section 2.14 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 2.14 Sanitation and refuse. (a) The following are...

  20. 47 CFR 73.4005 - Advertising-refusal to sell.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Advertising-refusal to sell. 73.4005 Section 73.4005 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Rules Applicable to All Broadcast Stations § 73.4005 Advertising—refusal to sell. See 412...

  1. Fire protection

    International Nuclear Information System (INIS)

    Janetzky, E.

    1980-01-01

    Safety and fire prevention measurements have to be treated like the activities developing, planning, construction and erection. Therefore it is necessary that these measurements have to be integrated into the activities mentioned above at an early stage in order to guarantee their effectiveness. With regard to fire accidents the statistics of the insurance companies concerned show that the damage caused increased in the last years mainly due to high concentration of material. Organization of fire prevention and fire fighting, reasons of fire break out, characteristics and behaviour of fire, smoke and fire detection, smoke and heat venting, fire extinguishers (portable and stationary), construction material in presence of fire, respiratory protection etc. will be discussed. (orig./RW)

  2. Refuse derived fuel (RDF) plasma torch gasification as a feasible route to produce low environmental impact syngas for the cement industry.

    Science.gov (United States)

    López-Sabirón, Ana M; Fleiger, Kristina; Schäfer, Stefan; Antoñanzas, Javier; Irazustabarrena, Ane; Aranda-Usón, Alfonso; Ferreira, Germán A

    2015-08-01

    Plasma torch gasification (PTG) is currently researched as a technology for solid waste recovery. However, scientific studies based on evaluating its environmental implications considering the life cycle assessment (LCA) methodology are lacking. Therefore, this work is focused on comparing the environmental effect of the emissions of syngas combustion produced by refuse derived fuel (RDF) and PTG as alternative fuels, with that related to fossil fuel combustion in the cement industry. To obtain real data, a semi-industrial scale pilot plant was used to perform experimental trials on RDF-PTG.The results highlight that PTG for waste to energy recovery in the cement industry is environmentally feasible considering its current state of development. A reduction in every impact category was found when a total or partial substitution of alternative fuel for conventional fuel in the calciner firing (60 % of total thermal energy input) was performed. Furthermore, the results revealed that electrical energy consumption in PTG is also an important parameter from the LCA approach. © The Author(s) 2015.

  3. 20 CFR 401.70 - Appeals of refusals to correct records or refusals to allow access to records.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Appeals of refusals to correct records or refusals to allow access to records. 401.70 Section 401.70 Employees' Benefits SOCIAL SECURITY... also inform you that you have a right to file a statement of disagreement with the decision. Your...

  4. Highly Flexible, Fire Resistant HybridSil Foams for Next Generation Fireproofing, Insulation, and Energy Absorption NASA Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this Phase I STTR program is to adapt NanoSonic's HybridSil™ nanocomposite technology for the creation of next generation highly flexible, fire...

  5. ENVIRONMENTAL AND SUSTAINABLE TECHNOLOGY EVALUATION: BIOMASS CO-FIRING IN INDUSTRIAL BOILERS--MINNESOTA POWER'S RAPIDS ENERGY CENTER

    Science.gov (United States)

    The U.S. EPA operates the Environmental and Sustainable Technology Evaluation (ESTE) program to facilitate the deployment of innovative technologies through performance verification and information dissemination. This ESTE project involved evaluation of co-firing common woody bio...

  6. Feasibility of landfill gas as a liquefied natural gas fuel source for refuse trucks.

    Science.gov (United States)

    Zietsman, Josias; Bari, Muhammad Ehsanul; Rand, Aaron J; Gokhale, Bhushan; Lord, Dominique; Kumar, Sunil

    2008-05-01

    The purpose of this paper is to develop a methodology to evaluate the feasibility of using landfill gas (LFG) as a liquefied natural gas (LNG) fuel source for heavy-duty refuse trucks operating on landfills. Using LFG as a vehicle fuel can make the landfills more self-sustaining, reduce their dependence on fossil fuels, and reduce emissions and greenhouse gases. Acrion Technologies Inc. in association with Mack Trucks Inc. developed a technology to generate LNG from LFG using the CO2 WASH process. A successful application of this process was performed at the Eco Complex in Burlington County, PA. During this application two LNG refuse trucks were operated for 600 hr each using LNG produced from gases from the landfill. The methodology developed in this paper can evaluate the feasibility of three LFG options: doing nothing, electricity generation, and producing LNG to fuel refuse trucks. The methodology involved the modeling of several components: LFG generation, energy recovery processes, fleet operations, economic feasibility, and decision-making. The economic feasibility considers factors such as capital, maintenance, operational, and fuel costs, emissions and tax benefits, and the sale of products such as surplus LNG and food-grade carbon dioxide (CO2). Texas was used as a case study. The 96 landfills in Texas were prioritized and 17 landfills were identified that showed potential for converting LFG to LNG for use as a refuse truck fuel. The methodology was applied to a pilot landfill in El Paso, TX. The analysis showed that converting LFG to LNG to fuel refuse trucks proved to be the most feasible option and that the methodology can be applied for any landfill that considers this option.

  7. Report on survey for possibility of applying bio-technologies to biomass in fiscal 1999. Aiming at developing a kitchen refuse and waste water treatment and energy production system that can be installed as an ancillary facility of buildings; 1999 nendo biomass eno bio technology oyo kanosei chosa hokokusho. Biru nado no futai setsubi to shite secchi kanona, chukai, haisui nado no shori narabi ni energy seisan system no kaihatsu wo mezashite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This paper describes the survey and discussion on a system to treat microorganisms generated from organic wastes and recover bio-gas energy as an ancillary facility of buildings. The roof of a building is the most suitable location in terms of open space and odor problem, and because the waste liquid after energy recovery can be flown into the city sewage system. Suitable processes for energy recovery are the primary fermentation, followed further by second stage fermentation purposed of reducing BOD. Since rapid enhancement of the efficiency cannot be expected from the present methane fermentation technologies, it is worth discussing to convert the first step from methane fermentation to hydrogen fermentation, for which technological development is indispensable. Permission by the national or local government would be an important condition. Organic wastes treatment systems with different scales may be considered from wastes treatment in each house to treatment of wastes after collection on the whole city basis. Treating wastes with high water content, such as kitchen refuses and human waste is beneficial among organic wastes being collected and treated by local governments. It is beneficial because sorted collection for that purpose can be carried out, and existing incineration systems can be operated more efficiently. (NEDO)

  8. Fire Stations

    Data.gov (United States)

    Department of Homeland Security — Fire Stations in the United States Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their...

  9. Characteristics and Outcomes of Elderly Patients Refused to ICU

    Directory of Open Access Journals (Sweden)

    María-Consuelo Pintado

    2013-01-01

    Full Text Available Background. There are few data regarding the process of deciding which elderly patients are refused to ICU admission, their characteristics, and outcome. Methods. Prospective longitudinal observational cohort study. We included all consecutive patients older than 75 years, who were evaluated for admission to but were refused to treatment in ICU, during 18 months, with 12-month followup. We collected demographic data, ICU admission/refusal reasons, previous functional and cognitive status, comorbidity, severity of illness, and hospital and 12-month mortality. Results. 338 elderly patients were evaluated for ICU admission and 88 were refused to ICU (26%. Patients refused because they were “too ill to benefit” had more comorbidity and worse functional and mental situation than those admitted to ICU; there were no differences in illness severity. Hospital mortality rate of the whole study cohort was 36.3%, higher in patients “too ill to benefit” (55.6% versus 35.8%, P<0.01, which also have higher 1-year mortality (73.7% versus 42.5%, P<0.01. High comorbidity, low functional status, unavailable ICU beds, and age were associated with refusal decision on multivariate analysis. Conclusions. Prior functional status and comorbidity, not only the age or severity of illness, can help us more to make the right decision of admitting or refusing to ICU patients older than 75 years.

  10. An Improved Flexible Solar Thermal Energy Integration Process for Enhancing the Coal-Based Energy Efficiency and NOx Removal Effectiveness in Coal-Fired Power Plants under Different Load Conditions

    Directory of Open Access Journals (Sweden)

    Yu Han

    2017-09-01

    Full Text Available An improved flexible solar-aided power generation system (SAPG for enhancing both selective catalytic reduction (SCR de-NOx efficiency and coal-based energy efficiency of coal-fired power plants is proposed. In the proposed concept, the solar energy injection point is changed for different power plant loads, bringing about different benefits for coal-fired power generation. For partial/low load, solar energy is beneficially used to increase the flue gas temperature to guarantee the SCR de-NOx effectiveness as well as increase the boiler energy input by reheating the combustion air. For high power load, solar energy is used for saving steam bleeds from turbines by heating the feed water. A case study for a typical 1000 MW coal-fired power plant using the proposed concept has been performed and the results showed that, the SCR de-NOx efficiency of proposed SAPG could increase by 3.1% and 7.9% under medium load and low load conditions, respectively, as compared with the reference plant. The standard coal consumption rate of the proposed SAPG could decrease by 2.68 g/kWh, 4.05 g/kWh and 6.31 g/kWh for high, medium and low loads, respectively, with 0.040 USD/kWh of solar generated electricity cost. The proposed concept opens up a novel solar energy integration pattern in coal-fired power plants to improve the pollutant removal effectiveness and decrease the coal consumption of the power plant.

  11. Solid Fuel - Oxygen Fired Combustion for Production of Nodular Reduced Iron to Reduce CO2 Emissions and Improve Energy Efficiencies

    Energy Technology Data Exchange (ETDEWEB)

    Donald R. Fosnacht; Richard F. Kiesel; David W. Hendrickson; David J. Englund; Iwao Iwasaki; Rodney L. Bleifuss; Mathew A. Mlinar

    2011-12-22

    The current trend in the steel industry is an increase in iron and steel produced in electric arc furnaces (EAF) and a gradual decline in conventional steelmaking from taconite pellets in blast furnaces. In order to expand the opportunities for the existing iron ore mines beyond their blast furnace customer base, a new material is needed to satisfy the market demands of the emerging steel industry while utilizing the existing infrastructure and materials handling capabilities. This demand creates opportunity to convert iron ore or other iron bearing materials to Nodular Reduced Iron (NRI) in a recently designed Linear Hearth Furnace (LHF). NRI is a metallized iron product containing 98.5 to 96.0% iron and 2.5 to 4% C. It is essentially a scrap substitute with little impurity that can be utilized in a variety of steelmaking processes, especially the electric arc furnace. The objective of this project was to focus on reducing the greenhouse gas emissions (GHG) through reducing the energy intensity using specialized combustion systems, increasing production and the use of biomass derived carbon sources in this process. This research examined the use of a solid fuel-oxygen fired combustion system and compared the results from this system with both oxygen-fuel and air-fuel combustion systems. The solid pulverized fuels tested included various coals and a bio-coal produced from woody biomass in a specially constructed pilot scale torrefaction reactor at the Coleraine Minerals Research Laboratory (CMRL). In addition to combustion, the application of bio-coal was also tested as a means to produce a reducing atmosphere during key points in the fusion process, and as a reducing agent for ore conversion to metallic iron to capture the advantage of its inherent reduced carbon footprint. The results from this study indicate that the approaches taken can reduce both greenhouse gas emissions and the associated energy intensity with the Linear Hearth Furnace process for converting

  12. Improvement of fire protection measures for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    Improvements of fire protection measures for nuclear power plants were performed as following items: Development of fire hazard analysis method. Application of developed Fire Dynamic Tool to actual plants (FDT{sup S}), With regard to fire tests for the fire data acquisition, cable fire test and High Energy Arcing Faults (HEAF) fire test were performed. Implementation of fire hazard analysis code and simulation were performed as following items: Fire analysis codes FDS, SYLVIA, and CFAST were implemented in order to analyze the fire progression phenomena. Trial simulation of HEAF accident of Onagawa NPP in Tohoku earthquake. (author)

  13. Long-term energy and climate implications of carbon capture and storage deployment strategies in the US coal-fired electricity fleet.

    Science.gov (United States)

    Sathre, Roger; Masanet, Eric

    2012-09-04

    To understand the long-term energy and climate implications of different implementation strategies for carbon capture and storage (CCS) in the US coal-fired electricity fleet, we integrate three analytical elements: scenario projection of energy supply systems, temporally explicit life cycle modeling, and time-dependent calculation of radiative forcing. Assuming continued large-scale use of coal for electricity generation, we find that aggressive implementation of CCS could reduce cumulative greenhouse gas emissions (CO(2), CH(4), and N(2)O) from the US coal-fired power fleet through 2100 by 37-58%. Cumulative radiative forcing through 2100 would be reduced by only 24-46%, due to the front-loaded time profile of the emissions and the long atmospheric residence time of CO(2). The efficiency of energy conversion and carbon capture technologies strongly affects the amount of primary energy used but has little effect on greenhouse gas emissions or radiative forcing. Delaying implementation of CCS deployment significantly increases long-term radiative forcing. This study highlights the time-dynamic nature of potential climate benefits and energy costs of different CCS deployment pathways and identifies opportunities and constraints of successful CCS implementation.

  14. Coal-fired generation

    CERN Document Server

    Breeze, Paul

    2015-01-01

    Coal-Fired Generation is a concise, up-to-date and readable guide providing an introduction to this traditional power generation technology. It includes detailed descriptions of coal fired generation systems, demystifies the coal fired technology functions in practice as well as exploring the economic and environmental risk factors. Engineers, managers, policymakers and those involved in planning and delivering energy resources will find this reference a valuable guide, to help establish a reliable power supply address social and economic objectives. Focuses on the evolution of the traditio

  15. Adsorber fires

    International Nuclear Information System (INIS)

    Holmes, W.

    1987-01-01

    The following conclusions are offered with respect to activated charcoal filter systems in nuclear power plants: (1) The use of activated charcoal in nuclear facilities presents a potential for deep-seated fires. (2) The defense-in-depth approach to nuclear fire safety requires that if an ignition should occur, fires must be detected quickly and subsequently suppressed. (3) Deep-seated fires in charcoal beds are difficult to extinguish. (4) Automatic water sprays can be used to extinguish fires rapidly and reliably when properly introduced into the burning medium. The second part of the conclusions offered are more like challenges: (1) The problem associated with inadvertent actuations of fire protection systems is not a major one, and it can be reduced further by proper design review, installation, testing, and maintenance. Eliminating automatic fire extinguishing systems for the protection of charcoal adsorbers is not justified. (2) Removal of automatic fire protection systems due to fear of inadvertent fire protection system operation is a case of treating the effect rather than the cause. On the other hand, properly maintaining automatic fire protection systems will preserve the risk of fire loss at acceptable levels while at the same time reducing the risk of damage presented by inadvertent operation of fire protection systems

  16. Refusal of Emergency Medical Treatment: Case Studies and Ethical Foundations.

    Science.gov (United States)

    Marco, Catherine A; Brenner, Jay M; Kraus, Chadd K; McGrath, Norine A; Derse, Arthur R

    2017-11-01

    Informed consent is an important component of emergency medical treatment. Most emergency department patients can provide informed consent for treatment upon arrival. Informed consent should also be obtained for emergency medical interventions that may entail significant risk. A related concept to informed consent is informed refusal of treatment. Patients may refuse emergency medical treatment during their evaluation and treatment. This article addresses important considerations for patients who refuse treatment, including case studies and discussion of definitions, epidemiology, assessment of decisional capacity, information delivery, medicolegal considerations, and alternative care plans. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  17. Optimization of use of waste in the future energy system

    DEFF Research Database (Denmark)

    Münster, Marie; Meibom, Peter

    2011-01-01

    of mixed waste, anaerobic digestion of organic waste, and gasification of part of the potential RDF (refuse derived fuel) for CHP (combined heat and power) production, while the remaining part is co-combusted with coal. Co-combustion mainly takes place in new coal-fired power plants, allowing investments...... production in Denmark in a 2025 scenario with 48% renewable energy. Investments in a range of waste conversion technologies are facilitated, including waste incineration, co-combustion with coal, anaerobic digestion, and gasification. The most economically feasible solutions are found to be incineration...

  18. Performing coolness: smoking refusal and adolescent identities.

    Science.gov (United States)

    Plumridge, E W; Fitzgerald, L J; Abel, G M

    2002-04-01

    The implications of smoking refusal for personal identity style were studied through conversations in six small focus groups or dyads of 13- and 14-year-old non-smokers from an urban New Zealand secondary school. The approach to analyzing their talk was informed by notions of 'performativity' and 'social space' to focus on the connections between identity and social relations. Smoking emerged as a key signifier of power and status. It was salient at both top and bottom ends of the social hierarchy depending upon the competence displayed in smoking as part of a larger ensemble of personal deportment and behavior. Being a non-smoker therefore inevitably carried connotations of being 'average' or 'in the middle', presenting non-smoking adolescents with the problem of accrediting themselves against superior 'smoker cool' groups. A discourse analytic approach was used to examine the resources and strategies participants brought to bear on this 'problem', which was then seen to be solved differently by boys and girls. Boys could establish alternatives to 'smoker cool' through physical activity, girls had little recourse but to accept their inferior status. The implications of this for health education and promotion are discussed.

  19. US Fire Administration Fire Statistics

    Data.gov (United States)

    Department of Homeland Security — The U.S. Fire Administration collects data from a variety of sources to provide information and analyses on the status and scope of the fire problem in the United...

  20. Forest fires

    International Nuclear Information System (INIS)

    Fuller, M.

    1991-01-01

    This book examines the many complex and sensitive issues relating to wildland fires. Beginning with an overview of the fires of 1980s, the book discusses the implications of continued drought and considers the behavior of wildland fires, from ignition and spread to spotting and firestorms. Topics include the effects of weather, forest fuels, fire ecology, and the effects of fire on plants and animals. In addition, the book examines firefighting methods and equipment, including new minimum impact techniques and compressed air foam; prescribed burning; and steps that can be taken to protect individuals and human structures. A history of forest fire policies in the U.S. and a discussion of solutions to fire problems around the world completes the coverage. With one percent of the earth's surface burning every year in the last decade, this is a penetrating book on a subject of undeniable importance

  1. Forest fires in Pennsylvania.

    Science.gov (United States)

    Donald A. Haines; William A. Main; Eugene F. McNamara

    1978-01-01

    Describes factors that contribute to forest fires in Pennsylvania. Includes an analysis of basic statistics; distribution of fires during normal, drought, and wet years; fire cause, fire activity by day-of-week; multiple-fire day; and fire climatology.

  2. 49 CFR 219.213 - Unlawful refusals; consequences.

    Science.gov (United States)

    2010-10-01

    ... inconsistent with the employee's health, whether such refusal was made in good faith and based on medical..., as appropriate, also consider the following: (1) Whether the railroad made a good faith determination...

  3. Retrofit options to enable biomass firing at Irish peat plants: Background report 4.2 for the EU Joule 2+ project: Energy from biomass: An assessment of two promising systems for energy production

    International Nuclear Information System (INIS)

    Van den Broek, R.; Faaij, A.; Blaney, G.

    1995-05-01

    An overview is given of the most promising options for retrofitting existing Irish peat plants to accept biomass fuel. It is expected that with low investment costs the existing peat stations can be adapted to enable them to fire biomass. It will also be possible to co-fire peat and biomass, this option will become a way of using biomass in power generation with relatively low risk, both on the field of initial investments and supply security. The objectives of this report are: assessing the different technical options for retrofitting the plants to enable biomass firing; provide investment costs, efficiencies, emissions and expected lifetimes for the different retrofit options. The results from this study are used in the final integration phase of the EU-Joule project 'Energy from biomass'. Chapter 2 deals with methodological considerations which have been made in estimation of the investment costs. In chapter 3 the present situation is described. Both peat harvesting and power plant operation of both sod and milled peat plants are explained. Also some past experiences with wood chips firing in Irish peat stations are discussed. Chapter 4 gives a general view on retrofitting peat plants to enable biomass firing. Some starting points like biomass fuel feeding and emission standards that have to be met are highlighted. The rationale behind four main choices are given. Finally, a technical description is presented of the two boiler adaptations that will be considered among the different retrofit options, namely conversion of milled peat units into bubbling fluidized bed and into a whole tree energy unit. Six retrofit options are described in more detail in chapter 5. Information is given on the present status of the plants, the technical considerations of the retrofit, expected performance and an estimation of a range in which the investment costs can be expected. 4 figs., 10 tabs., 5 appendices

  4. Clean Cities Niche Market Overview: Refuse Haulers (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    Shea, S.

    2011-09-01

    Refuse haulers are ideal for the adoption of alternative fuels and advanced vehicle technologies. By using fuels like natural gas, propane, or biodiesel, and technologies like hybrid electric and hydraulic hybrid systems, the refuse-hauling sector could substantially decrease its petroleum use and greenhouse gas emissions. Fleet managers should explore the benefits of the fuels and technologies available, as well as the individual fleet needs, before adoption.

  5. Jehovah's Witnesses and autonomy: honouring the refusal of blood transfusions.

    Science.gov (United States)

    Bock, Gregory L

    2012-11-01

    This paper explores the scriptural and theological reasons given by Jehovah's Witnesses (JWs) to refuse blood transfusions. Julian Savulescu and Richard W Momeyer argue that informed consent should be based on rational beliefs and that the refusal of blood transfusions by JWs is irrational, but after examining the reasons given by JWs, I challenge the claim that JW beliefs are irrational. I also question whether we should give up the traditional notion of informed consent.

  6. [The refusal of nursing care by the families].

    Science.gov (United States)

    Curchod, Claude; Fisher, Marion

    2016-10-01

    Caregiving is complex. While it is not easy to admit that the process can be refused by the patient, it is no easier when it is refused by the patient's family. Accepting this fact is however an essential stage in the relational and care processes. The family must therefore be supported by professionals in order to be able to make an enlightened choice. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. [Refusal of treatments by an adult cancer patient].

    Science.gov (United States)

    Dauchy, Sarah; Faivre, Jean-Christophe; Block, Véronique; Metzger, Maude; Salleron, Julia; Charles, Cécile; Adam, Virginie

    2018-03-01

    Refusal of treatment questions the treatment's adequacy as well as the quality of the care relationship. A rigorous analysis of these situations is necessary in order to respect the patient's fundamental right to decide for him/herself while preventing a potential loss of chance. This paper proposes practical guidelines for assessment and management of the refusal of treatment by adult cancer patients. The French Association for Supportive Care in Cancer and the French Society for Psycho-Oncology formed a task force that applied a consensus methodology to draft guidelines. We propose five guidelines: (1) be informed of the conditions most often associated with refusal of treatment so as to reinforce adequate support measures; (2) understand the complexity of the process of refusal and accurately identify what is precisely refused; (3) apply an approach of systematic analysis to refusal, to try and increase the possibilities of finding an agreement while reinforcing the respect of the patient's position; (4) establish a legal procedure to address refusal of treatment that safeguards the stakeholders when no accord can be found; and (5) know the indications for ethical collective decision-making. A systematic assessment procedure of treatment refusal is necessary in order to ensure that all the physical, psychological and contextual aspects of it are taken into account, and to provide patients with the best treatment possible. The setting of good care relationship, the improvement of communication skills training and of comprehensive multidisciplinary care are all crucial elements in the prevention of these situations. Copyright © 2018 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  8. Arsenic burden survey among refuse incinerator workers

    Directory of Open Access Journals (Sweden)

    Chao Chung-Liang

    2005-01-01

    Full Text Available Background: Incinerator workers are not considered to have arsenic overexposure although they have the risk of overexposure to other heavy metals. Aim: To examine the relationship between arsenic burden and risk of occupational exposure in employees working at a municipal refuse incinerator by determining the concentrations of arsenic in the blood and urine. Settings and Design: The workers were divided into three groups based on their probability of contact with combustion-generated residues, namely Group 1: indirect contact, Group 2: direct contact and Group 3: no contact. Healthy age- and sex-matched residents living in the vicinity were enrolled as the control group. Materials and Methods: Heavy metal concentrations were measured by atomic absorption spectrophotometer. Downstream rivers and drinking water of the residents were examined for environmental arsenic pollution. A questionnaire survey concerning the contact history of arsenic was simultaneously conducted. Statistical analysis: Non-parametric tests, cross-tabulation and multinomial logistic regression. Results: This study recruited 122 incinerator workers. The urine and blood arsenic concentrations as well as incidences of overexposure were significantly higher in the workers than in control subjects. The workers who had indirect or no contact with combustion-generated residues had significantly higher blood arsenic level. Arsenic contact history could not explain the difference. Airborne and waterborne arsenic pollution were not detected. Conclusion: Incinerator workers run the risk of being exposed to arsenic pollution, especially those who have incomplete protection in the workplace even though they only have indirect or no contact with combustion-generated pollutants.

  9. Factors related to treatment refusal in Taiwanese cancer patients.

    Science.gov (United States)

    Chiang, Ting-Yu; Wang, Chao-Hui; Lin, Yu-Fen; Chou, Shu-Lan; Wang, Ching-Ting; Juang, Hsiao-Ting; Lin, Yung-Chang; Lin, Mei-Hsiang

    2015-01-01

    Incidence and mortality rates for cancer have increased dramatically in the recent 30 years in Taiwan. However, not all patients receive treatment. Treatment refusal might impair patient survival and life quality. In order to improve this situation, we proposed this study to evaluate factors that are related to refusal of treatment in cancer patients via a cancer case manager system. This study analysed data from a case management system during the period from 2010 to 2012 at a medical center in Northern Taiwan. We enrolled a total of 14,974 patients who were diagnosed with cancer. Using the PRECEDE Model as a framework, we conducted logistic regression analysis to identify independent variables that are significantly associated with refusal of therapy in cancer patients. A multivariate logistic regression model was also applied to estimate adjusted the odds ratios (ORs) with 95% confidence intervals (95%CI). A total of 253 patients (1.69%) refused treatment. The multivariate logistic regression result showed that the high risk factors for refusal of treatment in cancer patient included: concerns about adverse effects (prefuse treatment have poor survival. The present study provides evidence of factors that are related to refusal of therapy and might be helpful for further application and improvement of cancer care.

  10. Pervasive refusal syndrome. Three German cases provide further illustration.

    Science.gov (United States)

    Jans, Thomas; Ball, Juliane; Preiss, Maike; Haberhausen, Michael; Warnke, Andreas; Renner, Tobias J

    2011-09-01

    Pervasive refusal syndrome (PRS) has been proposed as a new diagnostic entity among child and adolescent psychiatric disorders. It is characterized by a cluster of life-threatening symptoms including refusal of hood intake, decreased or complete lack of mobilization, and lack of communication as well as retreat from normal life activities. Active refusal to accept help as well as neglect of personal care have been core features of PRS in the limited number of cases reported in the last decade. There have, however; been cases with predominantly passive resistance, indicating the possibility that there may be a continuum from active refusal to passive resistance within PRS. Postulating this continuum allows for the integration of "depressive devitalization" -- a refusal syndrome mainly characterized by passive resistance -- into the concept of PRS. Here, three case vignettes of adolescent patients with PRS are presented. The patients' symptomatology can be allocated on this continuum of PRS. PRS and dissociative disorders are compared in greater detail and contrasted within this discussion of differential diagnoses at the poles of such a continuum. PRS is a useful diagnosis for cases involving symptoms of predominating refusal and retreat which cannot satisfactorily be classified by existing diagnostic categories, and which can mostly clearly be separated from dissociative disorder.

  11. Refusal of emergency caesarean section in Ireland: a relational approach.

    Science.gov (United States)

    Wade, Katherine

    2014-01-01

    This article examines the issue of emergency caesarean section refusal. This raises complex legal and ethical issues surrounding autonomy, capacity, and the right to refuse treatment. In Ireland, the situation is complicated further by the constitutional right to life of the unborn. While cases involving caesarean section refusal have occurred in other jurisdictions, a case of this nature has yet to be reported in Ireland. This article examines possible ways in which the interaction of a woman's right to refuse treatment and the right to life of the unborn could be approached in Ireland in the context of caesarean section refusal. The central argument of the article is that the liberal individualistic approach to autonomy evident in the caesarean section cases in England and Wales is difficult to apply in the Irish context, due to the conflicting constitutional rights of the woman and foetus. Thus, alternative visions of autonomy which take the interests and rights of others into account in medical decision-making are examined. In particular, this article focuses on the concept of relational consent, as developed by Alasdair Maclean and examines how such an approach could be applied in the context of caesarean section refusal in Ireland. The article explains why this approach is particularly appropriate and identifies mechanisms through which such a theory of consent could be applied. It is argued that this approach enhances a woman's right to autonomy, while at the same time allows the right to life of the unborn to be defended.

  12. Design optimization and sensitivity analysis of a biomass-fired combined cooling, heating and power system with thermal energy storage systems

    International Nuclear Information System (INIS)

    Caliano, Martina; Bianco, Nicola; Graditi, Giorgio; Mongibello, Luigi

    2017-01-01

    Highlights: • A novel operation strategy for biomass-fired combined cooling, heating and power system is presented. • A design optimization of the system is conducted. • The effects of variation of the incentive for the electricity generation are evaluated. • The effects of the variation of the absorption chiller size and the thermal energy storage system one are evaluated. • The inclusion of a cold storage system into the combined cooling, heating and power system is also analyzed. - Abstract: In this work, an operation strategy for a biomass-fired combined cooling, heating and power system, composed of a cogeneration unit, an absorption chiller, and a thermal energy storage system, is formulated in order to satisfy time-varying energy demands of an Italian cluster of residential multi-apartment buildings. This operation strategy is adopted for performing the economical optimization of the design of two of the devices composing the combined cooling, heating and power system, namely the absorption chiller and the storage system. A sensitivity analysis is carried out in order to evaluate the impact of the incentive for the electricity generation on the optimized results, and also to evaluate, separately, the effects of the variation of the absorption chiller size, and the effects of the variation of the thermal energy storage system size on the system performance. In addition, the inclusion into the system of a cold thermal energy storage system is analyzed, as well, assuming different possible values for the cold storage system cost. The results of the sensitivity analysis indicate that the most influencing factors from the economical point of view are represented by the incentive for the electricity generation and the absorption chiller power. Results also show that the combined use of a thermal energy storage and of a cold thermal energy storage during the hot season could represent a viable solution from the economical point of view.

  13. Production, quality and quality assurance of Refuse Derived Fuels (RDFs).

    Science.gov (United States)

    Sarc, R; Lorber, K E

    2013-09-01

    This contribution describes characterization, classification, production, application and quality assurance of Refuse Derived Fuels (RDFs) that are increasingly used in a wide range of co-incineration plants. It is shown in this paper, that the fuel-parameter, i.e. net calorific value [MJ/kg(OS)], particle size d(90) or d(95) [mm], impurities [w%], chlorine content [w%], sulfur content [w%], fluorine content [w%], ash content [w%], moisture [w%] and heavy metals content [mg/kg(DM)], can be preferentially used for the classification of different types of RDF applied for co-incineration and substitution of fossil-fuel in different industial sectors. Describing the external production of RDF by processing and confectioning of wastes as well as internal processing of waste at the incineration plant, a case study is reported on the application of RDF made out of different household waste fractions in a 120,000t/yr Waste to Energy (WtE) circulating fluidized bed (CFB) incinerator. For that purpose, delivered wastes, as well as incinerator feedstock material (i.e. after internal waste processing) are extensively investigated. Starting with elaboration of sampling plan in accordance with the relevant guidelines and standards, waste from different suppliers was sampled. Moreover, manual sorting analyses and chemical analyses were carried out. Finally, results of investigations are presented and discussed in the paper. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. 46 CFR 28.820 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.820 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel must be equipped with a self-priming, power driven fire...

  15. Wildland fire limits subsequent fire occurrence

    Science.gov (United States)

    Sean A. Parks; Carol Miller; Lisa M. Holsinger; Scott Baggett; Benjamin J. Bird

    2016-01-01

    Several aspects of wildland fire are moderated by site- and landscape-level vegetation changes caused by previous fire, thereby creating a dynamic where one fire exerts a regulatory control on subsequent fire. For example, wildland fire has been shown to regulate the size and severity of subsequent fire. However, wildland fire has the potential to influence...

  16. An investigation on the fuel savings potential of hybrid hydraulic refuse collection vehicles.

    Science.gov (United States)

    Bender, Frank A; Bosse, Thomas; Sawodny, Oliver

    2014-09-01

    Refuse trucks play an important role in the waste collection process. Due to their typical driving cycle, these vehicles are characterized by large fuel consumption, which strongly affects the overall waste disposal costs. Hybrid hydraulic refuse vehicles offer an interesting alternative to conventional diesel trucks, because they are able to recuperate, store and reuse braking energy. However, the expected fuel savings can vary strongly depending on the driving cycle and the operational mode. Therefore, in order to assess the possible fuel savings, a typical driving cycle was measured in a conventional vehicle run by the waste authority of the City of Stuttgart, and a dynamical model of the considered vehicle was built up. Based on the measured driving cycle and the vehicle model including the hybrid powertrain components, simulations for both the conventional and the hybrid vehicle were performed. Fuel consumption results that indicate savings of about 20% are presented and analyzed in order to evaluate the benefit of hybrid hydraulic vehicles used for refuse collection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Situation testing: the case of health care refusal.

    Science.gov (United States)

    Després, C; Couralet, P-E

    2011-04-01

    Situation testing to assess physicians' refusal to provide healthcare is increasingly used in research studies. This paper aims to explain the relevance and limits of this method. Conducted in 2008-2009, this study was designed to assess the rate of healthcare refusal among several categories of private practitioners toward patients covered by the French public means-tested complementary health insurance (CMUc) when they requested a first appointment by phone. The other objectives were to study the determinants of healthcare refusal and assess the method. The study was conducted on a representative sample of Paris-based dentists and physicians in five categories: general practitioners, medical gynecologists, ophthalmologists, radiologists, and dentists. The method was based on two protocols. In the first scenario, an actor pretended to be a CMUc beneficiary and, in the second one, he did not give information about his health coverage but hinted at a low socioeconomic status. The two protocols were compared and procedures checking the relation between refusal and CMUc coverage were implemented in each of them. In the scenario in which the patient declared being a CMUc beneficiary, the results showed different refusal rates depending on the type of practitioner, physician, or dentist, their specialty, and whether or not, they charge more than the standard set fee. In the second scenario, refusal rates were much lower. The comparison of the two protocols seems to confirm the existence of discrimination based on CMUc affiliation rather than patients' socioeconomic status. The discussion presents the limits of situation testing, which remains an experimental instrument because it does not observe reality but reveals behaviors in situation. The findings cannot be extrapolated and are limited in time. The statistical analysis is only valid if the procedure followed is precise and applied consistently using a preset scenario. In addition, the discriminatory nature of the

  18. Coal fires in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Whitehouse, Alfred E.; Mulyana, Asep A.S. [Office of Surface Mining/Ministry of Energy and Mineral Resources Coal Fire Project, Ministry of Energy and Mineral Resources, Agency for Training and Education, Jl. Gatot Subroto, Kav. 49, Jakarta 12950 (Indonesia)

    2004-07-12

    Indonesia's fire and haze problem is increasingly being ascribed to large-scale forest conversion and land clearing activities making way for pulpwood, rubber and oil palm plantations. Fire is the cheapest tool available to small holders and plantation owners to reduce vegetation cover and prepare and fertilize extremely poor soils. Fires that escaped from agricultural burns have ravaged East Kalimantan forests on the island of Borneo during extreme drought periods in 1982-1983, 1987, 1991, 1994 and 1997-1998. Estimates based on satellite data and ground observations are that more than five million hectares were burned in East Kalimantan during the 1997/1998 dry season. Not only were the economic losses and ecological damage from these surface fires enormous, they ignited coal seams exposed at the ground surface along their outcrops.Coal fires now threaten Indonesia's shrinking ecological resources in Kutai National Park and Sungai Wain Nature Reserve. Sungai Wain has one of the last areas of unburned primary rainforest in the Balikpapan-Samarinda area with an extremely rich biodiversity. Although fires in 1997/1998 damaged nearly 50% of this Reserve and ignited 76 coal fires, it remains the most valuable water catchment area in the region and it has been used as a reintroduction site for the endangered orangutan. The Office of Surface Mining provided Indonesia with the capability to take quick action on coal fires that presented threats to public health and safety, infrastructure or the environment. The US Department of State's Southeast Asia Environmental Protection Initiative through the US Agency for International Development funded the project. Technical assistance and training transferred skills in coal fire management through the Ministry of Energy and Mineral Resource's Training Agency to the regional offices; giving the regions the long-term capability to manage coal fires. Funding was also included to extinguish coal fires as

  19. Fire intensity impacts on post-fire temperate coniferous forest net primary productivity

    Science.gov (United States)

    Sparks, Aaron M.; Kolden, Crystal A.; Smith, Alistair M. S.; Boschetti, Luigi; Johnson, Daniel M.; Cochrane, Mark A.

    2018-02-01

    Fire is a dynamic ecological process in forests and impacts the carbon (C) cycle through direct combustion emissions, tree mortality, and by impairing the ability of surviving trees to sequester carbon. While studies on young trees have demonstrated that fire intensity is a determinant of post-fire net primary productivity, wildland fires on landscape to regional scales have largely been assumed to either cause tree mortality, or conversely, cause no physiological impact, ignoring the impacted but surviving trees. Our objective was to understand how fire intensity affects post-fire net primary productivity in conifer-dominated forested ecosystems on the spatial scale of large wildland fires. We examined the relationships between fire radiative power (FRP), its temporal integral (fire radiative energy - FRE), and net primary productivity (NPP) using 16 years of data from the MOderate Resolution Imaging Spectrometer (MODIS) for 15 large fires in western United States coniferous forests. The greatest NPP post-fire loss occurred 1 year post-fire and ranged from -67 to -312 g C m-2 yr-1 (-13 to -54 %) across all fires. Forests dominated by fire-resistant species (species that typically survive low-intensity fires) experienced the lowest relative NPP reductions compared to forests with less resistant species. Post-fire NPP in forests that were dominated by fire-susceptible species were not as sensitive to FRP or FRE, indicating that NPP in these forests may be reduced to similar levels regardless of fire intensity. Conversely, post-fire NPP in forests dominated by fire-resistant and mixed species decreased with increasing FRP or FRE. In some cases, this dose-response relationship persisted for more than a decade post-fire, highlighting a legacy effect of fire intensity on post-fire C dynamics in these forests.

  20. Risk factors associated with treatment refusal in lung cancer.

    Science.gov (United States)

    Suh, Won Na; Kong, Kyoung Ae; Han, Yeji; Kim, Soo Jung; Lee, Su Hwan; Ryu, Yon Ju; Lee, Jin Hwa; Shim, Sung Shine; Kim, Yookyung; Chang, Jung Hyun

    2017-09-01

    The incidence of lung cancer is increasing with longer life expectancy. Refusal of active treatment for cancer is prone to cause patients to experience more severe symptoms and shorten survival. The purpose of this study was to define the factors related to refusal or abandonment of active therapy in lung cancer. We retrospectively reviewed the data of 617 patients from medical records from 2010 to 2014. Two groups were formed: 149 patients who refused anti-cancer treatment and allowed only palliative care were classified into the non-treatment group, while the remaining 468 who received anti-cancer treatment were classified into the treatment group. The groups differed significantly in age, employment, relationship status, number of offspring, educational status, body mass index, presence of chest and systemic symptoms, Charlson Comorbidity Index, Eastern Cooperative Oncology Group score, and tumor node metastasis stage ( P refusal of cancer treatment. Individual factors, such as old age, low educational status, low weight, and poor performance status can influence refusal of cancer treatment in patients with lung cancer, and should be considered prior to consultation with patients. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  1. On fire

    DEFF Research Database (Denmark)

    Hansen, Helle Rabøl

    The title of this paper: “On fire”, refers to two (maybe three) aspects: firstly as a metaphor of having engagement in a community of practice according to Lave & Wenger (1991), and secondly it refers to the concrete element “fire” in the work of the fire fighters – and thirdly fire as a signifier...

  2. Fire Power

    Science.gov (United States)

    Denker, Deb; West, Lee

    2009-01-01

    For education administrators, campus fires are not only a distressing loss, but also a stark reminder that a campus faces risks that require special vigilance. In many ways, campuses resemble small communities, with areas for living, working and relaxing. A residence hall fire may raise the specter of careless youth, often with the complication of…

  3. 46 CFR 28.315 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... After September 15, 1991, and That Operate With More Than 16 Individuals on Board § 28.315 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel 36 feet (11.8 meters) or more in length must...

  4. Forest-fire models

    Science.gov (United States)

    Haiganoush Preisler; Alan Ager

    2013-01-01

    For applied mathematicians forest fire models refer mainly to a non-linear dynamic system often used to simulate spread of fire. For forest managers forest fire models may pertain to any of the three phases of fire management: prefire planning (fire risk models), fire suppression (fire behavior models), and postfire evaluation (fire effects and economic models). In...

  5. Co-firing biomass and fossil fuels

    International Nuclear Information System (INIS)

    Junge, D.C.

    1991-01-01

    In June 1989, the Alaska Energy Authority and the University of Alaska Anchorage published a monograph summarizing the technology of co-firing biomass and fossil fuels. The title of the 180 page monograph is 'Use of Mixed Fuels in Direct Combustion Systems'. Highlights from the monograph are presented in this paper with emphasis on the following areas: (1) Equipment design and operational experience co-firing fuels; (2) The impact of co-firing on efficiency; (3) Environmental considerations associated with co-firing; (4) Economic considerations in co-firing; and (5) Decision making criteria for co-firing

  6. Costs and potentials of energy conservation in China's coal-fired power industry: A bottom-up approach considering price uncertainties

    International Nuclear Information System (INIS)

    Chen, Hao; Kang, Jia-Ning; Liao, Hua; Tang, Bao-Jun; Wei, Yi-Ming

    2017-01-01

    Energy conservation technologies in the coal-fired power sector are important solutions for the environmental pollution and climate change issues. However, a unified framework for estimating their costs and potentials is still needed due to the wide technology choices, especially considering their economic feasibility under fuel and carbon price uncertainties. Therefore, this study has employed a bottom-up approach to analyze the costs and potentials of 32 key technologies’ new promotions during the 13th Five-Year Plan period (2016–2020), which combines the conservation supply curve (CSC) approach and break-even analysis. Findings show that (1) these 32 technologies have a total coal conservation potential of 275.77 Mt with a cost of 238.82 billion yuan, and their break-even coal price is 866 yuan/ton. (2) steam-water circulation system has the largest energy conservation potential in the coal-fired power industry. (3) considering the co-benefits will facilitate these technologies’ promotions, because their break-even coal prices will decrease by 2.35 yuan/ton when the carbon prices increase by 1 yuan/ton. (4) discount rates have the largest impacts on the technologies’ cost-effectiveness, while the future generation level affect their energy conservation potentials most. - Highlights: • The 32 technologies can save 275.77 Mt coal with a cost of 238.82 billion yuan. • The steam-water circulation system has the largest energy conservation potential. • Considering the co-benefits will facilitate the technology promotions • Discount rates have the largest impacts on the technologies’ cost-effectiveness.

  7. A method for ensemble wildland fire simulation

    Science.gov (United States)

    Mark A. Finney; Isaac C. Grenfell; Charles W. McHugh; Robert C. Seli; Diane Trethewey; Richard D. Stratton; Stuart Brittain

    2011-01-01

    An ensemble simulation system that accounts for uncertainty in long-range weather conditions and two-dimensional wildland fire spread is described. Fuel moisture is expressed based on the energy release component, a US fire danger rating index, and its variation throughout the fire season is modeled using time series analysis of historical weather data. This analysis...

  8. Knowledge-based fault diagnosis system for refuse collection vehicle

    International Nuclear Information System (INIS)

    Tan, CheeFai; Juffrizal, K.; Khalil, S. N.; Nidzamuddin, M. Y.

    2015-01-01

    The refuse collection vehicle is manufactured by local vehicle body manufacturer. Currently; the company supplied six model of the waste compactor truck to the local authority as well as waste management company. The company is facing difficulty to acquire the knowledge from the expert when the expert is absence. To solve the problem, the knowledge from the expert can be stored in the expert system. The expert system is able to provide necessary support to the company when the expert is not available. The implementation of the process and tool is able to be standardize and more accurate. The knowledge that input to the expert system is based on design guidelines and experience from the expert. This project highlighted another application on knowledge-based system (KBS) approached in trouble shooting of the refuse collection vehicle production process. The main aim of the research is to develop a novel expert fault diagnosis system framework for the refuse collection vehicle

  9. Knowledge-based fault diagnosis system for refuse collection vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Tan, CheeFai; Juffrizal, K.; Khalil, S. N.; Nidzamuddin, M. Y. [Centre of Advanced Research on Energy, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, Durian Tunggal, Melaka (Malaysia)

    2015-05-15

    The refuse collection vehicle is manufactured by local vehicle body manufacturer. Currently; the company supplied six model of the waste compactor truck to the local authority as well as waste management company. The company is facing difficulty to acquire the knowledge from the expert when the expert is absence. To solve the problem, the knowledge from the expert can be stored in the expert system. The expert system is able to provide necessary support to the company when the expert is not available. The implementation of the process and tool is able to be standardize and more accurate. The knowledge that input to the expert system is based on design guidelines and experience from the expert. This project highlighted another application on knowledge-based system (KBS) approached in trouble shooting of the refuse collection vehicle production process. The main aim of the research is to develop a novel expert fault diagnosis system framework for the refuse collection vehicle.

  10. Responding to the refusal of care in the emergency department.

    Science.gov (United States)

    Nelson, Jennifer; Venkat, Arvind; Davenport, Moira

    2014-01-01

    The emergency department (ED) serves as the primary gateway for acute care and the source of health care of last resort. Emergency physicians are commonly expected to rapidly assess and treat patients with a variety of life-threatening conditions. However, patients do refuse recommended therapy, even when the consequences are significant morbidity and even mortality. This raises the ethical dilemma of how emergency physicians and ED staff can rapidly determine whether patient refusal of treatment recommendations is based on intact decision-making capacity and how to respond in an appropriate manner when the declining of necessary care by the patient is lacking a basis in informed judgment. This article presents a case that illustrates the ethical tensions raised by the refusal of life-sustaining care in the ED and how such situations can be approached in an ethically appropriate manner.

  11. Sodium bicarbonate effects on the anaerobic digestion of refuse

    Energy Technology Data Exchange (ETDEWEB)

    Kasali, G.B.; Senior, E.; Watson-Craik, I.A. (Strathclyde Univ., Glasgow (UK). Dept. of Applied Physics)

    1989-01-01

    Laboratory column and bottle cultures were used to examine the efficacy of NaHCO{sub 3}additions (1%, 2.5% and 5% w/v) to promote the solid-state refuse fermentation. Buffering capacity increase, by addition of 2.5% NaHCO{sub 3}, equivalent to 84 mg NaHCO{sub 3} g dry weight refuse{sup -1}, promoted both acidogenesis and methanogenesis, with the latter accelerating by a factor of six, compared with glass-distilled water controls. Increased addition, with 5% NaHCO{sub 3}, however, mediated partial suppression of methanogenesis and acidogenesis with cation toxicity the most likely cause. Promotion of the refuse fermentation by NaHCO{sub 3} addition, therefore, necessitates careful control of the concentration applied. (author).

  12. Refurbishment priorities at the Russian coal-fired power sector for cleaner energy production-Case studies

    International Nuclear Information System (INIS)

    Grammelis, P.; Koukouzas, N.; Skodras, G.; Kakaras, E.; Tumanovsky, A.; Kotler, V.

    2006-01-01

    The paper aims to present the current status of the coal-fired power sector in Russia, the prospects for renovation activities based on Clean Coal Technologies (CCT) and two case studies on potential refurbishment projects. Data were collected for 180 thermoelectric units with capacity higher than 100 MWe and the renovation needs of the power sector, among the retrofitting, repowering and reconstruction options, were estimated through a multi-criteria analysis. The most attractive system to renovate a power plant between the Supercritical Combustion (SC) and the Fluidized Bed Combustion (FBC) technologies was evaluated. The application of each of the aforementioned technologies at the Kashirskaya and Shaturskaya power plants was studied and their replication potential in the Russian coal-fired power plant park was examined. Nowadays, the installed capacity of coal-fired power plants in the Russian Federation is 29.3 GWe, while they account for about 19% of the total electricity generation in the area. The low efficiency and especially the advanced age are the determinant factors for renovation applications at the Russian units. Even in the more conservative modernization scenario, over 30% of the thermoelectric units have to be repowered or reconstructed. Concrete proposals about the profitable and reliable operation of two Russian thermoelectric units with minimized environmental effects were elaborated. A new unit of 315 MWe with supercritical steam parameters and reburning for NO x abatement is envisaged to upgrade Unit 1 of Kashirskaya power station, while new Circulating Fluidized Bed (CFB) boilers of the same steam generation is the most promising renovation option for the boilers of Unit 1 in Shaturskaya power station

  13. Refurbishment priorities at the Russian coal-fired power sector for cleaner energy production-Case studies

    Energy Technology Data Exchange (ETDEWEB)

    Grammelis, P. [Centre for Research and Technology Hellas/Institute of Solid Fuels Technology and Applications (CERTH/ISFTA), 4 km N.R. Ptolemaida-Kozani, P.O. Box 95, Ptolemaida 50200 (Greece) and Laboratory of Steam Boilers and Thermal Plants, Mechanical Engineering Department, National Technical University of Athens, Athens (Greece)]. E-mail: pgra@central.ntua.gr; Koukouzas, N. [Centre for Research and Technology Hellas/Institute of Solid Fuels Technology and Applications (CERTH/ISFTA), 4 km N.R. Ptolemaida-Kozani, P.O. Box 95, Ptolemaida 50200 (Greece); Skodras, G. [Centre for Research and Technology Hellas/Institute of Solid Fuels Technology and Applications (CERTH/ISFTA), 4 km N.R. Ptolemaida-Kozani, P.O. Box 95, Ptolemaida 50200 (Greece); Kakaras, E. [Centre for Research and Technology Hellas/Institute of Solid Fuels Technology and Applications (CERTH/ISFTA), 4 km N.R. Ptolemaida-Kozani, P.O. Box 95, Ptolemaida 50200 (Greece); Laboratory of Steam Boilers and Thermal Plants, Mechanical Engineering Department, National Technical University of Athens, Athens (Greece); Tumanovsky, A. [VTI All Russia Thermal Engineering Institute (Russian Federation); Kotler, V. [VTI All Russia Thermal Engineering Institute (Russian Federation)

    2006-11-15

    The paper aims to present the current status of the coal-fired power sector in Russia, the prospects for renovation activities based on Clean Coal Technologies (CCT) and two case studies on potential refurbishment projects. Data were collected for 180 thermoelectric units with capacity higher than 100 MWe and the renovation needs of the power sector, among the retrofitting, repowering and reconstruction options, were estimated through a multi-criteria analysis. The most attractive system to renovate a power plant between the Supercritical Combustion (SC) and the Fluidized Bed Combustion (FBC) technologies was evaluated. The application of each of the aforementioned technologies at the Kashirskaya and Shaturskaya power plants was studied and their replication potential in the Russian coal-fired power plant park was examined. Nowadays, the installed capacity of coal-fired power plants in the Russian Federation is 29.3 GWe, while they account for about 19% of the total electricity generation in the area. The low efficiency and especially the advanced age are the determinant factors for renovation applications at the Russian units. Even in the more conservative modernization scenario, over 30% of the thermoelectric units have to be repowered or reconstructed. Concrete proposals about the profitable and reliable operation of two Russian thermoelectric units with minimized environmental effects were elaborated. A new unit of 315 MWe with supercritical steam parameters and reburning for NO {sub x} abatement is envisaged to upgrade Unit 1 of Kashirskaya power station, while new Circulating Fluidized Bed (CFB) boilers of the same steam generation is the most promising renovation option for the boilers of Unit 1 in Shaturskaya power station.

  14. Technical and Energy Performance of an Advanced, Aqueous Ammonia-Based CO2 Capture Technology for a 500 MW Coal-Fired Power Station.

    Science.gov (United States)

    Li, Kangkang; Yu, Hai; Feron, Paul; Tade, Moses; Wardhaugh, Leigh

    2015-08-18

    Using a rate-based model, we assessed the technical feasibility and energy performance of an advanced aqueous-ammonia-based postcombustion capture process integrated with a coal-fired power station. The capture process consists of three identical process trains in parallel, each containing a CO2 capture unit, an NH3 recycling unit, a water separation unit, and a CO2 compressor. A sensitivity study of important parameters, such as NH3 concentration, lean CO2 loading, and stripper pressure, was performed to minimize the energy consumption involved in the CO2 capture process. Process modifications of the rich-split process and the interheating process were investigated to further reduce the solvent regeneration energy. The integrated capture system was then evaluated in terms of the mass balance and the energy consumption of each unit. The results show that our advanced ammonia process is technically feasible and energy-competitive, with a low net power-plant efficiency penalty of 7.7%.

  15. [Maternal refusal to consent to a cesarean delivery, stillbirth].

    Science.gov (United States)

    Defline, A; Obadia, M; El Djerbi, A; Plevy, P; Lepercq, J

    2014-01-01

    The doctor-lawyer perspective that we discuss is a maternal refusal to consent to a cesarean delivery for a fetal indication in June 2011. Despite repeated information of the risks during a three-week hospitalization for pre-eclampsia, after being assured of the proper understanding of the seriousness of the situation by the patient and spouse, and after consideration to transfer to another hospital, the reiterated refusal led to a late fetal extraction resulting in term stillbirth. Copyright © 2013. Published by Elsevier Masson SAS.. All rights reserved.

  16. Fire safety

    International Nuclear Information System (INIS)

    Keski-Rahkonen, O.; Bjoerkman, J.; Hostikka, S.; Mangs, J.; Huhtanen, R.; Palmen, H.; Salminen, A.; Turtola, A.

    1998-01-01

    According to experience and probabilistic risk assessments, fires present a significant hazard in a nuclear power plant. Fires may be initial events for accidents or affect safety systems planned to prevent accidents and to mitigate their consequences. The project consists of theoretical work, experiments and simulations aiming to increase the fire safety at nuclear power plants. The project has four target areas: (1) to produce validated models for numerical simulation programmes, (2) to produce new information on the behavior of equipment in case of fire, (3) to study applicability of new active fire protecting systems in nuclear power plants, and (4) to obtain quantitative knowledge of ignitions induced by important electric devices in nuclear power plants. These topics have been solved mainly experimentally, but modelling at different level is used to interpret experimental data, and to allow easy generalisation and engineering use of the obtained data. Numerical fire simulation has concentrated in comparison of CFD modelling of room fires, and fire spreading on cables on experimental data. So far the success has been good to fair. A simple analytical and numerical model has been developed for fire effluents spreading beyond the room of origin in mechanically strongly ventilated compartments. For behaviour of equipment in fire several full scale and scaled down calorimetric experiments were carried out on electronic cabinets, as well as on horizontal and vertical cable trays. These were carried out to supply material for CFD numerical simulation code validation. Several analytical models were developed and validated against obtained experimental results to allow quick calculations for PSA estimates as well as inter- and extrapolations to slightly different objects. Response times of different commercial fire detectors were determined for different types of smoke, especially emanating from smoldering and flaming cables to facilitate selection of proper detector

  17. Experimental study of fire barriers preventing vertical fire spread in ETISs

    Directory of Open Access Journals (Sweden)

    Xin Huang

    2013-11-01

    Full Text Available In recent years, the external thermal insulation system (ETIS has been applied increasingly in a large amount of buildings for energy conservation purpose. However, the increase use of combustible insulation materials in the ETIS has raised serious fire safety problems. Fires involving this type of ETIS have caused severe damage and loss. In order to improve its fire safety, fire barriers were suggested to be installed. This paper introduces fire experiments that have been done to study the effects of fire barriers on preventing vertical fire spread along the ETIS. The experiments were performed according to BS 8414-1:2002 “Fire performance of external cladding systems – Part 1: Test method for non-loadbearing external cladding systems applied to the face of the building”. The test facility consists of a 9 m high wall. The fire sources were wood cribs with a fire size of 3 ± 0.5 MW. The insulation materials were expanded polystyrene foam (EPS. The fire barrier was a horizontal strip of rockwool with a width of 300 mm. Thermocouples were used to measure temperatures outside and inside the ETIS. A series of experiments with different fire scenarios were done: no fire barrier, two fire barriers and three fire barriers at different heights. Test results were compared. The results show that the ETIS using EPS without fire barriers almost burned out, while the ETIS with fire barriers performed well in preventing fire spread. The temperatures above the fire barrier were much lower than those below the fire barrier, and most of the insulation materials above the top fire barrier stayed in place.

  18. Windscale fire

    International Nuclear Information System (INIS)

    Auxier, J.A.

    1986-01-01

    A graphite fire in the Windscale No. 1 reactor occurred during the period October 8-12, 1957. The Windscale reactors were located on a coastal plain in northwest England and were used to produce plutonium. A great wealth of information was gathered on the causes, handling, decontamination, and environmental effects of reactor accidents. Topics of discussion include: the cause of the fire; handling of the incident; radiation doses to the population; and radiation effects on the population

  19. Fire protection versus energy conservation? Smoke escape systems for elevator shafts; Brandschutz kontra EnEV? Aufzugsschachtentrauchung

    Energy Technology Data Exchange (ETDEWEB)

    Seifert, K. [BTR Brandschutz-Technik und Rauchabzug GmbH, Hamburg (Germany)

    2003-11-01

    Most casualties in case of a fire are caused by smoke inhalation. Next to other combustion products, the carbon monoxide concentration in the air available for breathing is the most important parameter for survival in a burning room. Even very low concentrations of carbon monoxide in breathing air will cause severe irritations, lasting health effects, and death. Further, there is the problem of panic in elevators. [German] ''Brandtote sind Rauchtote'', diese Aussage ist nicht erst seit dem Duesseldorfer Flughafenbrand in aller Munde. Neben anderen Verbrennungsprodukten ist der Kohlenmonoxidgehalt in der Atemluft wohl die wichtigste Kenngroesse fuer die Ueberlebensmoeglichkeit in einem Brandraum. Bereits geringe Anteile in der Atemluft fuehren zu schwersten Irritationen, bleibenden Gesundheitsschaeden oder zum Tode. Hinzu kommt fuer den Benutzer eines Aufzuges die nie auszuschliessende Panik im Brandfall. (orig.)

  20. 7 CFR 319.8-26 - Material refused entry.

    Science.gov (United States)

    2010-01-01

    ... Plant Protection Act (7 U.S.C. 7714 and 7731). Neither the Department of Agriculture nor the inspector... 7 Agriculture 5 2010-01-01 2010-01-01 false Material refused entry. 319.8-26 Section 319.8-26 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION...

  1. 9 CFR 93.806 - Animals refused entry.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Animals refused entry. 93.806 Section 93.806 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS IMPORTATION OF...

  2. Magnetometric Studies of Catalyst Refuses in Nanocarbon Materials

    Directory of Open Access Journals (Sweden)

    Eklund Peter

    2008-01-01

    Full Text Available AbstractIt is shown that magnetometry can be employed as an effective tool to control the content of a ferromagnetic constituent in nanocarbon materials. We propose a thermochemical treatment protocol to achieve extensive cleaning of the source nanocarbon materials from ferromagnetic refuses.

  3. [Refusal of personal hygiene care and nursing responsibility].

    Science.gov (United States)

    Peyé, Anne

    2013-03-01

    Situations of patients refusing personal hygiene care are frequent. Sources of difficulties and questioning for caregivers, they can lead to maltreatment. In order to avoid this pitfall, it is essential to support the teams in their approach around representations of caregiving and nursing responsibility.

  4. the development of new generation of solid waste refuse incinerators

    African Journals Online (AJOL)

    Apart from town refuse, there are wastes from agriculturally based industries especially ... depends on careful control of the 3T's (time, temperature and turbulence). ... These activities cause serious public health risks ... The modifications to the old bottle incinerators were developed by carefully assessing the failure modes.

  5. Ways to Say No: Refusal Skill Strategies among Urban Adolescents

    Science.gov (United States)

    Nichols, Tracy R.; Graber, Julia A.; Brooks-Gunn, Jeanne; Botvin, Gilbert J.

    2006-01-01

    Objectives: To examine associations among adolescents' generated verbal strategies (ie, Simple No, Declarative Statements, Excuse, Alternatives) and underlying nonverbal assertiveness in 2 refusal situations: smoking and shoplifting. Methods: Sixth-grade urban minority students (N = 454) participated in videotaped role-play assessments of peer…

  6. Autonomy, religious values, and refusal of lifesaving medical treatment.

    Science.gov (United States)

    Wreen, M J

    1991-09-01

    The principal question of this paper is: Why are religious values special in refusal of lifesaving medical treatment? This question is approached through a critical examination of a common kind of refusal of treatment case, one involving a rational adult. The central value cited in defence of honouring such a patient's refusal is autonomy. Once autonomy is isolated from other justificatory factors, however, possible cases can be imagined which cast doubt on the great valuational weight assigned it by strong anti-paternalists. This weight is sufficient, in their estimation, to justify honouring the patient's refusal. There is thus a tension between the strong anti-paternalist's commitment to the sufficiency of autonomy and our intuitions respecting such cases. Attempts can be made to relieve this tension, such as arguing that patients aren't really rational in the circumstances envisaged, or that other values, such as privacy or bodily integrity, if added to autonomy, are sufficient to justify an anti-paternalistic stance. All such attempts fail, however. But what does not fail is the addition of religious freedom, freedom respecting a patient's religious beliefs and values. Why religious freedom reduces the tension is then explained, and the specialness of religious beliefs and values examined.

  7. Problems and prospects of refuse disposal in nigerian urban centres ...

    African Journals Online (AJOL)

    Refuse disposal is one of the major environmental problems that developing ... The problem of waste management has two parts, that of collection and that of disposal. ... Disposal methods such as dumping sites, incineration, recycling, shipping ... citizenry has roles to play in adopting more suitable solutions to this problem.

  8. [Refusal of care in the intensive care: how makes decision?].

    OpenAIRE

    Borel , Marie; Veber , Benoit; Villette-Baron , Karen; Hariri , S.; Dureuil , Bertrand; Hervé , Christian

    2009-01-01

    International audience; It is not a question of going towards a systematic admission in intensive care of any patient proposed, but to make sure that so if there is a refusal, it is carried out according to a step ethically acceptable.

  9. [Refusal of care and respect of the body].

    Science.gov (United States)

    Bernard, Marie-Fleur

    Patients receive numerous care procedures which they may refuse for physical and/or psychological reasons, even if, sometimes, the consequences for them can be dramatic. Faced with this situation, caregivers are helpless. Only ethical reflection centred on their responsibility and their humanity can guide them towards the suitable attitude to adopt. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Invitation Refusals in Cameroon French and Hexagonal French

    Science.gov (United States)

    Farenkia, Bernard Mulo

    2015-01-01

    Descriptions of regional pragmatic variation in French are lacking to date the focus has been on a limited range of speech acts, including apologies, requests, compliments and responses to compliments. The present paper, a systematic analysis of invitation refusals across regional varieties of French, is designed to add to the research on…

  11. Refuse Dumps And The Environment: A Case Study Of Some ...

    African Journals Online (AJOL)

    Refuse Dumps And The Environment: A Case Study Of Some Selected Cities In Nigeria. ... International Journal of Emotional Psychology and Sport Ethics ... This study assessed the level of environmental pollution in the nation by focusing on the degree of accumulation of house – hold wastes, industrial scraps or wastes, ...

  12. Refuse derived fuel incineration: Fuel gas monitoring and analysis

    International Nuclear Information System (INIS)

    Ranaldi, E.; Coronidi, M.; De Stefanis, P.; Di Palo, C.; Zagaroli, M.

    1993-11-01

    Experience and results on refuse derived fuel (selected from municipal solid wastes) incineration are reported. The study involved the investigation of inorganic compounds (heavy metals, acids and toxic gases) emissions, and included feeding materials and incineration residues characterization and mass balance

  13. Bioethics and religious bodies: refusal of blood transfusions in Germany.

    Science.gov (United States)

    Rajtar, Małgorzata

    2013-12-01

    The refusal of medical treatment is a recurrent topic in bioethical debates and Jehovah's Witnesses often constitute an exemplary case in this regard. The refusal of a potentially life-saving blood transfusion is a controversial choice that challenges the basic medical principle of acting in patients' best interests and often leads physicians to adopt paternalistic attitudes toward patients who refuse transfusion. However, neither existing bioethical nor historical and social sciences scholarship sufficiently addresses experiences of rank-and-file Witnesses in their dealings with the health care system. This article draws on results of a nine-month (2010, 2011-2012) ethnographic research on the relationship between religious, legal, ethical, and emotional issues emerging from the refusal of blood transfusions by Jehovah's Witnesses in Germany (mainly in Berlin). It shows how bioethical challenges are solved in practice by some German physicians and what they perceive to be the main goal of biomedicine: promoting the health or broadly understood well-being of patients. I argue that two different understandings of the concept of autonomy are at work here: autonomy based on reason and autonomy based on choice. The first is privileged by German physicians in line with a Kantian philosophical tradition and constitutional law; the second, paradoxically, is utilized by Jehovah's Witnesses in their version of the Anglo-Saxon Millian approach. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Understanding Excessive School Absenteeism as School Refusal Behavior

    Science.gov (United States)

    Dube, Shanta R.; Orpinas, Pamela

    2009-01-01

    Understanding excessive absenteeism is important to ameliorating the negative outcomes associated with the behavior. The present study examined behavioral reinforcement profiles of school refusal behavior: negative reinforcement (avoidance) and positive reinforcement (gaining parental attention or receiving tangible benefits from not attending…

  15. Othermotherwork: "Testimonio" and the Refusal of Historical Trauma

    Science.gov (United States)

    Vega, Christine

    2018-01-01

    This paper is an "ofrenda" (offering), a "testimonio" (testimony) of the healing power of reconstituting severed relationships and reconstructing agentic creation stories in the pathology of soul-wounds where pictures and "cuentos" serve to mend genealogical traumas. This paper is a refusal of neglecting traumas, it…

  16. School Refusal Behavior: Classification, Assessment, and Treatment Issues.

    Science.gov (United States)

    Lee, Marcella I.; Miltenberger, Raymond G.

    1996-01-01

    Discusses diagnostic and functional classification, assessment, and treatment approaches for school refusal behavior. Diagnostic classification focuses on separation anxiety disorder, specific phobia, social phobia, depression, and truancy. Functional classification focuses on the maintaining consequences of the behavior, such as avoidance of…

  17. Combustion products of plastics as indicators for refuse burning in the atmosphere.

    Science.gov (United States)

    Simoneit, Bernd R T; Medeiros, Patricia M; Didyk, Borys M

    2005-09-15

    Despite all of the economic problems and environmental discussions on the dangers and hazards of plastic materials, plastic production worldwide is growing at a rate of about 5% per year. Increasing techniques for recycling polymeric materials have been developed during the last few years; however, a large fraction of plastics are still being discarded in landfills or subjected to intentional or incidental open-fire burning. To identify specific tracer compounds generated during such open-fire combustion, both smoke particles from burning and plastic materials from shopping bags, roadside trash, and landfill garbage were extracted for gas chromatography-mass spectrometry analyses. Samples were collected in Concón, Chile, an area frequently affected by wildfire incidents and garbage burning, and the United States for comparison. Atmospheric samples from various aerosol sampling programs are also presented as supportive data. The major components of plastic extracts were even-carbon-chain n-alkanes (C16-C40), the plasticizer di-2-ethylhexyl phthalate, and the antioxidants and lubricants/antiadhesives Irganox 1076, Irgafos 168, and its oxidation product tris(2,4-di-tertbutylphenyl) phosphate. Major compounds in smoke from burning plastics include the non-source-specific n-alkanes (mainly even predominance), terephthalic acid, phthalates, and 4-hydroxybenzoic acid, with minor amounts of polycyclic aromatic hydrocarbons (including triphenylbenzenes) and tris(2,4-di-tert-butylphenyl)phosphate. 1,3,5-Triphenylbenzene and tris(2,4-di-tert-butylphenyl)- phosphate were found in detectable amounts in atmospheric samples where plastics and refuse were burned in open fires, and thus we propose these two compounds as specific tracers for the open-burning of plastics.

  18. In-situ characterization of wildland fire behavior

    Science.gov (United States)

    Bret Butler; D. Jimenez; J. Forthofer; Paul Sopko; K. Shannon; Jim Reardon

    2010-01-01

    A system consisting of two enclosures has been developed to characterize wildand fire behavior: The first enclosure is a sensor/data logger combination that measures and records convective/radiant energy released by the fire. The second is a digital video camera housed in a fire proof enclosure that records visual images of fire behavior. Together this system provides...

  19. Impact of interventions for patients refusing emergency medical services transport.

    Science.gov (United States)

    Alicandro, J; Hollander, J E; Henry, M C; Sciammarella, J; Stapleton, E; Gentile, D

    1995-06-01

    To evaluate the effect of a documentation checklist and on-line medical control contact on ambulance transport of out-of-hospital patients refusing medical assistance. Consecutive patients served by four suburban ambulance services who initially refused emergency medical services (EMS) transport to the hospital were prospectively enrolled. In phase 1 (control phase), all patients who initially refused medical attention or transport had an identifying data card completed. In phase 2 (documentation phase), out-of-hospital providers completed a similar data card that contained a checklist of high-risk criteria for a poor outcome if not transported. In phase 3 (intervention phase), a data card similar to that used in phase 2 was completed, and on-line medical control was contacted for all patients with high-risk criteria who refused transport. The primary endpoint was the percentage of patients transported to the hospital. A total of 361 patients were enrolled. Transport rate varied by phase: control, 17 of 144 (12%); documentation, 11 of 150 (7%); and intervention, 12 of 67 (18%) (chi-square, p = 0.023). Transport of high-risk patients improved with each intervention: control, two of 60 (3%); documentation, seven of 70 (10%); and intervention, 12 of 34 (35%) (chi-square, p = 0.00003). Transport of patients without high-risk criteria decreased with each intervention: control, 15 of 84 (18%); documentation, four of 80 (5%); and intervention, 0 of 33 (0%) (p = 0.0025). Of the 28 patients for whom medical control was contacted, 12 (43%) were transported to the hospital, and only three of these 12 patients (25%) were released from the ED. Contact with on-line medical control increased the likelihood of transport of high-risk patients who initially refused medical assistance. The appropriateness of the decreased transport rate of patients not meeting high-risk criteria needs further evaluation.

  20. Refusal of dialysis amongst patients of chronic kidney disease (CKD)

    International Nuclear Information System (INIS)

    Anees, M.; Khan, J.A.

    2014-01-01

    This study was conducted to determine the refusal of dialysis amongst patients of chronic kidney disease presenting for the first time for dialysis in uremic condition. Study Design: Cross sectional Study. Place and Duration of the Study: Outpatient department of Nephrology, Mayo Hospital, Lahore from 1 st Jan 2012 to 31 st December 2012. Patients and Methods: Patients of CKD due to any cause presenting with uremia for the first time for dialysis were included in the study. History and physical examination was done and demographic data was collected in pre designed form. Patients were offered for dialysis while explaining to them the advantages of getting and disadvantages of not getting dialysis. Patient's response on the offer was recorded and the reason for the refusal were noted. Results: According to the criteria 150 patients were included in the study. Most of the patients were male 92 (61.3%) and illiterate 78 (52.0%). Major cause of CKD was diabetes mellitus 58 (38.7%) followed by hypertension 38 (25.3%). Mean age of the patients was 42.59 ± 13.72 year and income of themost of the patients 126 (84%) was less than US$100/-month. Most of the patients 126 (77.0%) were asked about the need of dialysis in less than three months, 61 (41.3%) offered for the first time and amongst them 85 (54.0%) were offered dialysis already. Majority of the patients 101 (67.3%) refused dialysis when it was offered to them for the first time. Major reason of the refusal was fear of dialysis procedure in 76 (76%) patients followed by treatment by spiritual 14 (14%) and alternative ways and others 11 (11 %). Middle age persons refused dialysis significantly. (author)

  1. Assessing the Risk of Prehospital Administration of Naloxone with Subsequent Refusal of Care.

    Science.gov (United States)

    Levine, Michael; Sanko, Stephen; Eckstein, Marc

    2016-01-01

    EMS providers frequently encounter opioid-toxic patients who receive naloxone and then refuse further medical care. Older studies revealed this practice to be safe. In light of the evolving patterns of opioid abuse, this study attempted to determine the safety of this practice. This is a retrospective review of all patient encounters by the Los Angeles Fire Department (LAFD) between July 1, 2011-December 31, 2013. All LAFD patient encounters are stored electronically. These electronic records were reviewed for subjects who received naloxone had a documented respiratory rate (RR) less than 12, and subsequently refused transport. Data abstracted included name, social security number (SSN), date of birth (DOB), date of EMS encounter, age, and treatment rendered. The names, SSN, and DOB, as available, were supplied to the coroner's office. The Coroner's records were reviewed to determine if a patient with the same or similar name (e.g., Jon vs. Jonathan) had died within 24 hours, 30 days, or 6 months of the initial EMS encounter. The abstractor was blinded to the study hypothesis. 205 subjects were identified; the median (IQR) age was 41 (29-53) years. 27 (13%) were female. One subject (0.49%) died within 24 hours of the initial EMS encounter. The cause of death (COD) was coronary artery disease and heroin use. Two additional subjects (1. %) died within 30 days. One of these subjects died 6 days later; the COD is unknown. The other subject died 20 days after the EMS encounter; the COD was cardiovascular disease and liver cirrhosis. No additional subjects were identified at the 6 month follow up. A third subject died of a heroin overdose 16 months after the initial EMS encounter, but was beyond the pre-defined follow up period. The practice of receiving pre-hospital naloxone by paramedics and subsequently refusing care is associated with an extremely low short- and intermediate-term mortality. Despite an evolving pattern of opioid abuse, the results of this study

  2. Strategies for 2nd generation biofuels in EU - Co-firing to stimulate feedstock supply development and process integration to improve energy efficiency and economic competitiveness

    International Nuclear Information System (INIS)

    Berndes, Goeran; Hansson, Julia; Egeskog, Andrea; Johnsson, Filip

    2010-01-01

    The present biofuel policies in the European Union primarily stimulate 1st generation biofuels that are produced based on conventional food crops. They may be a distraction from lignocellulose based 2nd generation biofuels - and also from biomass use for heat and electricity - by keeping farmers' attention and significant investments focusing on first generation biofuels and the cultivation of conventional food crops as feedstocks. This article presents two strategies that can contribute to the development of 2nd generation biofuels based on lignocellulosic feedstocks. The integration of gasification-based biofuel plants in district heating systems is one option for increasing the energy efficiency and improving the economic competitiveness of such biofuels. Another option, biomass co-firing with coal, generates high-efficiency biomass electricity and reduces CO 2 emissions by replacing coal. It also offers a near-term market for lignocellulosic biomass, which can stimulate development of supply systems for biomass also suitable as feedstock for 2nd generation biofuels. Regardless of the long-term priorities of biomass use for energy, the stimulation of lignocellulosic biomass production by development of near term and cost-effective markets is judged to be a no-regrets strategy for Europe. Strategies that induce a relevant development and exploit existing energy infrastructures in order to reduce risk and reach lower costs, are proposed an attractive complement the present and prospective biofuel policies. (author)

  3. Fire protection program fiscal year 1995 site support program plan, Hanford Fire Department

    International Nuclear Information System (INIS)

    Good, D.E.

    1994-09-01

    The mission of the Hanford Fire Department (HFD) is to support the safe and timely cleanup of the Hanford site by providing fire suppression, fire prevention, emergency rescue, emergency medical service, and hazardous materials response; and to be capable of dealing with and terminating emergency situations which could threaten the operations, employees, or interest of the US Department of Energy operated Hanford Site. This includes response to surrounding fire departments/districts under a mutual aid agreement and contractual fire fighting, hazardous materials, and ambulance support to Washington Public Power Supply System (Supply System). The fire department also provides site fire marshal overview authority, fire system testing and maintenance, self-contained breathing apparatus maintenance, building tours and inspections, ignitable and reactive waste site inspections, prefire planning, and employee fire prevention education. This report describes the specific responsibilities and programs that the HFD must support and the estimated cost of this support for FY1995

  4. Fire Protection Program fiscal year 1996, site support program plan Hanford Fire Department. Revision 2

    International Nuclear Information System (INIS)

    Good, D.E.

    1995-09-01

    The mission of the Hanford Fire Department (HFD) is to support the safe and timely cleanup of the Hanford site by providing fire suppression, fire prevention, emergency rescue, emergency medical service, and hazardous materials response; and to be capable of dealing with and terminating emergency situations which could threaten the operations, employees, or interest of the US Department of Energy operated Hanford Site. This includes response to surrounding fire departments/districts under a mutual aid agreement and contractual fire fighting, hazardous materials, and ambulance support to Washington Public Power Supply System (Supply System). The fire department also provides site fire marshal overview authority, fire system testing and maintenance, self-contained breathing apparatus maintenance, building tours and inspections, ignitable and reactive waste site inspections, prefire planning, and employee fire prevention education. This report gives a program overview, technical program baselines, and cost and schedule baseline

  5. 76 FR 29796 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Refuse...

    Science.gov (United States)

    2011-05-23

    ... for OMB Review; Comment Request; Refuse Piles and Impounding Structures, Recordkeeping and Reporting... Administration (MSHA) sponsored information collection request (ICR) titled, ``Refuse Piles and Impounding... to submit annual reports and certification on refuse piles and impoundments to the agency and to keep...

  6. Social Skills, Competence, and Drug Refusal Efficacy as Predictors of Adolescent Alcohol Use.

    Science.gov (United States)

    Scheier, Lawrence M.; Botvin, Gilbert J.; Diaz, Tracy; Griffin, Kenneth W.

    1999-01-01

    Examines the extent to which assertiveness and related social skills, personal competence, and refusal efficacy predict alcohol involvement in adolescents. Males were at higher risk for poor refusal skills and reported higher alcohol involvement. Youth characterized by poor social skill development reported lower refusal efficacy, lower grades,…

  7. A plea for uniform European definitions for organ donor potential and family refusal rates.

    NARCIS (Netherlands)

    Jansen, N.E.; Haase-Kromwijk, B.J.; Leiden, H.A. van; Weimar, W.; Hoitsma, A.J.

    2009-01-01

    Conversion of potential organ donors to actual donors is negatively influenced by family refusals. Refusal rates differ strongly among countries. Is it possible to compare refusal rates in order to be able to learn from countries with the best practices? We searched in the literature for reviews of

  8. Alternative Fuels Data Center: Virginia Cleans up With Natural Gas Refuse

    Science.gov (United States)

    Trucks Virginia Cleans up With Natural Gas Refuse Trucks to someone by E-mail Share Alternative Fuels Data Center: Virginia Cleans up With Natural Gas Refuse Trucks on Facebook Tweet about Alternative Fuels Data Center: Virginia Cleans up With Natural Gas Refuse Trucks on Twitter Bookmark Alternative

  9. 37 CFR 1.295 - Review of decision finally refusing to publish a statutory invention registration.

    Science.gov (United States)

    2010-07-01

    ... dissatisfied with the final refusal to publish a statutory invention registration for reasons other than... refunded if the final refusal to publish a statutory invention registration for reasons other than... refusing to publish a statutory invention registration. 1.295 Section 1.295 Patents, Trademarks, and...

  10. Academic Self-Attributions for Success and Failure in Mathematics and School Refusal

    Science.gov (United States)

    Gonzálvez, Carolina; Sanmartín, Ricardo; Vicent, María; Inglés, Cándido J.; Aparicio-Flores, M. Pilar; García-Fernández, José M.

    2018-01-01

    The aim of this research is twofold: to analyze the mean differences scores in mathematic self-attributions based on school refusal and to verify its predictive capability on high scores in school refusal. The Sydney Attribution Scale and the School Refusal Assessment Scale-Revised were administered to 1078 Spanish students (50.8% boys) aged…

  11. Active Fire Mapping Program

    Science.gov (United States)

    Active Fire Mapping Program Current Large Incidents (Home) New Large Incidents Fire Detection Maps MODIS Satellite Imagery VIIRS Satellite Imagery Fire Detection GIS Data Fire Data in Google Earth ...

  12. Fire Safety (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Fire Safety KidsHealth / For Parents / Fire Safety What's in ... event of a fire emergency in your home. Fire Prevention Of course, the best way to practice ...

  13. Fire Research Enclosure

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Simulates submarine fires, enclosed aircraft fires, and fires in enclosures at shore facilities .DESCRIPTION: FIRE I is a pressurizable, 324 cu m(11,400 cu...

  14. Fire-safety engineering and performance-based codes

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    project administrators, etc. The book deals with the following topics: • Historical presentation on the subject of fire • Legislation and building project administration • European fire standardization • Passive and active fire protection • Performance-based Codes • Fire-safety Engineering • Fundamental......Fire-safety Engineering is written as a textbook for Engineering students at universities and other institutions of higher education that teach in the area of fire. The book can also be used as a work of reference for consulting engineers, Building product manufacturers, contractors, building...... thermodynamics • Heat exchange during the fire process • Skin burns • Burning rate, energy release rate and design fires • Proposal to Risk-based design fires • Proposal to a Fire scale • Material ignition and flame spread • Fire dynamics in buildings • Combustion products and toxic gases • Smoke inhalation...

  15. Optimized Solvent for Energy-Efficient, Environmentally-Friendly Capture of CO{sub 2} at Coal-Fired Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Farthing, G. A.; Rimpf, L. M.

    2014-04-30

    The overall goal of this project, as originally proposed, was to optimize the formulation of a novel solvent as a critical enabler for the cost-effective, energy-efficient, environmentally-friendly capture of CO{sub 2} at coal-fired utility plants. Aqueous blends of concentrated piperazine (PZ) with other compounds had been shown to exhibit high rates of CO{sub 2} absorption, low regeneration energy, and other desirable performance characteristics during an earlier 5-year development program conducted by B&W. The specific objective of this project was to identify PZ-based solvent formulations that globally optimize the performance of coal-fired power plants equipped with CO{sub 2} scrubbing systems. While previous solvent development studies have tended to focus on energy consumption and absorber size, important issues to be sure, the current work seeks to explore, understand, and optimize solvent formulation across the full gamut of issues related to commercial application of the technology: capital and operating costs, operability, reliability, environmental, health and safety (EH&S), etc. Work on the project was intended to be performed under four budget periods. The objective of the work in the first budget period has been to identify several candidate formulations of a concentrated PZ-based solvent for detailed characterization and evaluation. Work in the second budget period would generate reliable and comprehensive property and performance data for the identified formulations. Work in the third budget period would quantify the expected performance of the selected formulations in a commercial CO{sub 2} scrubbing process. Finally, work in the fourth budget period would provide a final technology feasibility study and a preliminary technology EH&S assessment. Due to other business priorities, however, B&W has requested that this project be terminated at the end of the first budget period. This document therefore serves as the final report for this project. It

  16. The September 1957 Rocky Flats fire: A guide to record series of the Department of Energy and its contractors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-19

    The primary purpose of this guide is to help the DOE locate and make available information relating to the 1957 Rocky Flats fire. The records are arranged into six categories: administrative and general; facilities and equipment; production and materials handling; waste management; workplace and environmental monitoring; and employee occupational exposure and health. A brief explanation of each category follows. The administrative and general section pertains to the administration of individual contractor organizations and DOE divisions at Rocky Flats. It also contains records which encompass several different subject areas and therefore can not be placed in a single category. The facilities and equipment category relates to the routine construction and maintenance of plant buildings as well as the purchase and installation of equipment. The production and materials handling records relate primarily to the inventory and production of nuclear materials and weapons components. The waste management records series found under this heading relate to the storage, handling, treatment, and disposal of radioactive, chemical or mixed materials produced or used at Rocky Flats. The records consist mostly of waste sampling and shipment records. The workplace and environmental monitoring records series found in this section pertain to monitoring of the workplace. The section also includes records that document efforts to monitor the environment outside of buildings, either onsite or offsite. Records in this category consist of sampling data and environmental impact reports. The employee occupational exposure and health section pertains to documentation relating to the health and occupational exposures of employees and visitors at Rocky Flats. Records series consist generally of dosimeter data, radiation exposure records, and medical records. Many of the records contain personal data pertaining to individual employees and may therefore be Privacy Act systems and records.

  17. 10 CFR 36.27 - Fire protection.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Fire protection. 36.27 Section 36.27 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Design and Performance Requirements for Irradiators § 36.27 Fire protection. (a) The radiation room at a panoramic irradiator must...

  18. Leachate from market refuse and biomethanation study.

    Science.gov (United States)

    Mukherjee, S N; Kumar, Sunil

    2007-12-01

    The market place is considered to be an important centre of daily life of campus community. In India, as in Europe and the USA, other forms of shopping have emerged significantly and now predominate, for instance department stores and supermarkets. Though, it is suffered from poor waste management, but the place could be a potential source for obtaining non-conventional energy. The present study examined the quality of market waste management of the Indian Institute of Technology Campus along with the feasibility of biogas production from leachate generated in the waste. Solid wastes from different storage locations of the market place were collected and analyzed. The characteristics of solid wastes were found to be degradable in nature. The wastes, composed of 85% of vegetable origin, were placed in a container and water was added to to generate leachate. The self-purification efficiency of leachate was also studied in the Indian environment and compared with research findings in the USA under an identical moisture application rate. Leachate characterization was investigated both under saturated and submerged conditions. The treatability of leachate was studied in a laboratory-scale up-flow anaerobic filter with hollow burnt clay rings as packing media. It was observed that 4,000-6,000 mg/l would be the optimum range of inlet chemical oxygen demand (COD) concentration for leachate treatment because of the inhibitory effect of ammonia, sulphide, volatile fatty acids and toxic metals in high concentrations at higher strengths of leachate. The gas production rate was found to be at a maximum at 38 degrees C and containing 70-75% methane. From experimental data, it was revealed that 83% COD was removed with input COD concentration of 5,475 mg/l at 2 days hydraulic retention time with biogas yield coefficients of 0.61. The present study also investigated the removal efficiency of chloride, ammonia, sulphide and nitrate.

  19. Emissions from co-combustion of wood and household refuse

    International Nuclear Information System (INIS)

    Zhang, X.J.; Peterson, F.

    1996-01-01

    An investigation was carried out on the emissions produced in a 20 kW experimental boiler burning a combination of wood and household refuse. The wood content ranged form 10 to 50%. Direct sampling with Tenax adsorbent was used to cover a range of volatile organic compounds (VOCs). The measurements also included unburned hydrocarbons, carbon monoxide, carbon dioxide, oxygen and flue gas temperature. Combustion and emission parameters were recorded continuously with a multi-point data logger. VOCs were analyzed by gas chromatography and mass spectrometer (GC/MS). The main emphasis was placed on the effect of wood on VOC emissions. The results showed that as the wood content increased from 10 to 50%, there was a roughly linear increase in emissions of total VOCs. Carbon monoxide and unburned hydrocarbon emissions also increased. These results suggest that household refuse is a good substitute for wood as a boiler fuel, as it has a similar calorific value but fewer emissions. (Author)

  20. Fire Models and Design Fires

    DEFF Research Database (Denmark)

    Poulsen, Annemarie

    The aim of this project is to perform an experimental study on the influence of the thermal feedback on the burning behavior of well ventilated pre-flashover fires. For the purpose an experimental method has been developed. Here the same identical objects are tested under free burn conditions...... carried out by Carleton University and NRC-IRC performed on seven different types of fire loads representing commercial premises, comprise the tests used for the study. The results show that for some of the room test the heat release rate increased due to thermal feedback compared to free burn for a pre......-flashover fire. Two phenomena were observed, that relate well to theory was found. In an incipient phase the heat release rate rose with the temperature of the smoke layer/enclosure boundaries. This increase was also found to depend on the flammability properties of the burning object. The results also...

  1. Fiscal 2000 report on the development of high-efficiency refuse-fueled power generation technology; Kokoritsu haikibutsu hatsuden gijutsu kaihatsu 2000 nendo hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Efforts were made to develop a refuse gasification/fusion power generation technology to contribute to the effective utilization of unexploited energy and to reduction in greenhouse gas emissions. Developed in the technology of elevating steam temperature were the evaluation of high-temperature corrosion of SH materials and a high temperature dust removing system, dechlorination technology for the thermolysis process, and a ceramic-made high-temperature air heater. For the avoidance of exhaust gas reheating, development was carried out for a low-temperature denitration unit, stable refuse feeding system for reduction in the self-heat melting critical calorific value, waste plastic injection technology for reduction in the amount of external fuel injection, and so forth. The effect of the developed element technologies were evaluated and a detailed feasibility study was conducted for a refuse gas conversion power generation system using gas engine power generation for minor-scale general waste treatment facilities. In the survey of the trend of refuse-fueled power generation technologies, trend in Japan and advanced refuse-fueled power generation systems and their introduction in Europe and America were investigated. (NEDO)

  2. Research and Development of a New Silica-Alumina Based Cementitious Material Largely Using Coal Refuse for Mine Backfill, Mine Sealing and Waste Disposal Stabilization

    Energy Technology Data Exchange (ETDEWEB)

    Henghu Sun; Yuan Yao

    2012-06-29

    Coal refuse and coal combustion byproducts as industrial solid waste stockpiles have become great threats to the environment. To activate coal refuse is one practical solution to recycle this huge amount of solid waste as substitute for Ordinary Portland Cement (OPC). The central goal of this project is to investigate and develop a new silica-alumina based cementitious material largely using coal refuse as a constituent that will be ideal for durable construction, mine backfill, mine sealing and waste disposal stabilization applications. This new material is an environment-friendly alternative to Ordinary Portland Cement. The main constituents of the new material are coal refuse and other coal wastes including coal sludge and coal combustion products (CCPs). Compared with conventional cement production, successful development of this new technology could potentially save energy and reduce greenhouse gas emissions, recycle vast amount of coal wastes, and significantly reduce production cost. A systematic research has been conducted to seek for an optimal solution for enhancing pozzolanic reactivity of the relatively inert solid waste-coal refuse in order to improve the utilization efficiency and economic benefit as a construction and building material.

  3. [Anorexia and refusal to eat in the elderly].

    Science.gov (United States)

    Hazif-Thomas, Cyril; Thomas, Philippe

    2016-01-01

    The question of the links between anorexia and the refusal to eat in the elderly is often the cause of major difficulties with regard to therapeutic strategies within caregiving teams. Likewise, few studies have been carried out into the diachronic links between teenage anorexia and that of the elderly. The role of the multi-disciplinary team is essential. Copyright © 2015. Published by Elsevier Masson SAS.

  4. Lime helps establish crownvetch on coal-breaker refuse

    Science.gov (United States)

    Miroslaw M. Czapowskyj; Edward A. Sowa

    1976-01-01

    A study was begun in 1965 to determine the effect of lime fertilizer, and mulch on the establishment and growth of crownvetch crowns planted on anthracite coal-breaker refuse. After 7 years the lime application had by far the strongest effect. Both 2.5 and 5.0 tons per acre increased survival and ground cover manyfold, and both treatments were equally beneficial from...

  5. [Refusal of care in the intensive care: how makes decision?].

    Science.gov (United States)

    Borel, M; Veber, B; Villette-Baron, K; Hariri, S; Dureuil, B; Hervé, C

    2009-11-01

    Decision-making bringing to an admission or not in intensive care is complex. The aim of this study is to analyze with an ethical point of view the making decision process leading to the refusal and its consequences. It is proposed a setting in prospect through the principles of beneficence, non-maleficience, respect for autonomy, justice, and the Leonetti law. Prospective study in surgical reanimation at the University Hospital of Rouen over 9 months (November 2007-September 2008). Systematic collection for each non-admitted patient of the general characters, the methods of decision making, immediate becoming and within 48 h Constitution of two groups: patients for whom an admission in intensive care could be an unreasonable situation of obstinacy, and patients for whom an admission in reanimation would not be about unreasonable if it occurred. One hundred and fifty situations were analyzed. The potentially unreasonable character of an admission does not involve necessarily a refusal of care in intensive care. The question of the lack of place and equity in the access to the care is real but relative according to the typology of the patients. The research of the respect of the autonomy of the patient is difficult but could be facilitated. The Leonetti law does not appear to be able to be a framework with the situation of refusal of care in intensive care. It is not a question of going towards a systematic admission in intensive care of any patient proposed, but to make sure that so if there is a refusal, it is carried out according to a step ethically acceptable.

  6. Coal-fired combined plants and power stations with high-temperature reactors for the energy supply of tomorrow

    International Nuclear Information System (INIS)

    Knizia, K.; Simon, M.

    1989-01-01

    Dwindling resources as well as threatening climatic changes caused by CO 2 seem to make it necessary to increase the energy conversion processes which promise a relief with regard to both problematic situations. Promising are the development of the combined gas and steam turbine process for the electricity generation from coal, as well as that of the high-temperature reactor, which enables besides the generation of electric energy the provision of heat at a high temperature range, too. The combination of these two components in a partly modified form allows, moreover, the provision of a number of gaseous energy carriers. The authors present these two components in detail, describe their development stage, as well as their existing development potential. (orig.) [de

  7. A narrative review of studies of refusal of psychotropic medication in acute inpatient psychiatric care.

    Science.gov (United States)

    Owiti, J A; Bowers, L

    2011-09-01

    This paper offers a narrative review of the 22 studies of medication refusal in acute psychiatry. Because of varied definitions of medication refusal, diverse methodologies and few rigorous studies, it has not been possible to draw firm conclusions on the average rate of refusal of psychotropic medications in acute psychiatry. However, it is clear that medication refusal is common and leads to poor outcomes characterized by higher rates of seclusion, restraint, threats of, and actual, assaults and longer hospitalizations. There are no statistically significant differences between refusers and acceptors in gender, marital status and preadmission living arrangements. Although no firm conclusions on the influence of ethnicity, status at admission and diagnosis on refusal, the refusers are more likely to have higher number of previous hospitalizations and history of prior refusal. The review indicates that staff factors such as the use of temporary staff, lack of confidence in ward staff and ineffective ward structure are associated with higher rates of medication refusal. Comprehensive knowledge of why, and how, patients refuse medication is lacking. Research on medication refusal is still fragmented, of variable methodological quality and lacks an integrating model. © 2011 Blackwell Publishing.

  8. Environmental performance assessment of utility boiler energy conversion systems

    International Nuclear Information System (INIS)

    Li, Changchun; Gillum, Craig; Toupin, Kevin; Park, Young Ho; Donaldson, Burl

    2016-01-01

    Highlights: • Sustainability analyses of utility boilers are performed. • Natural gas fired boilers have the least CO_2 emissions in fossil fueled boilers. • Solar boilers rank last with an emergy yield ratio of 1.2. • Biomass boilers have the best emergy sustainability index. - Abstract: A significant amount of global electric power generation is produced from the combustion of fossil fuels. Steam boilers are one of the most important components for steam and electricity production. The objective of this paper is to establish a theoretical framework for the sustainability analysis of a utility boiler. These analyses can be used by decision-makers to diagnose and optimize the sustainability of a utility boiler. Seven utility boiler systems are analyzed using energy and embodied solar energy (emergy) principles in order to evaluate their environmental efficiencies. They include a subcritical coal fired boiler, a supercritical coal fired boiler, an oil fired boiler, a natural gas fired boiler, a concentrating solar power boiler utilizing a tower configuration, a biomass boiler, and a refuse derived fuel boiler. Their relative environmental impacts were compared. The results show that the natural gas boiler has significantly lower CO_2 emission than an equivalent coal or oil fired boiler. The refuse derived fuel boiler has about the same CO_2 emissions as the natural gas boiler. The emergy sustainability index of a utility boiler system is determined as the measure of its sustainability from an environmental perspective. Our analyses results indicate that the natural gas boiler has a relatively high emergy sustainability index compared to other fossil fuel boilers. Converting existing coal boilers to natural gas boilers is a feasible option to achieve better sustainability. The results also show that the biomass boiler has the best emergy sustainability index and it will remain a means to utilize the renewable energy within the Rankine steam cycle. Before

  9. Mental health consequences of abortion and refused abortion.

    Science.gov (United States)

    Watter, W W

    1980-02-01

    There is no scientific evidence to support the hypothesis put forth by Dr. Philip Ney in a recent article published in the Canadian Journal of Psychiatry that induced abortion is associated with an increase in child abuse. There are, however, numerous studies which support the contention that mandatory motherhood adversely affects the mental health of both the mother and the offspring. Studies conducted in Sweden, Scotland, and Czechoslovakia revealed that women who were refused abortions frequently experienced serious psychosocial difficulties for long periods of time following abortion refusal. Case controlled follow-up studies, conducted in Sweden and Czechoslovakia, of offspring born to women who were refused abortions demonstrated that a higher proportion of the unwanted children required psychiatric services, engaged in criminal behavior, and did less well in school than the controlled children. These studies have implications for the current Canadian law which permits a woman to obtain an abortion if pregnancy continuation will endanger her health. In view of the above statistical evidence, and the fact that mortality and morbidity are known to be lower for abortion than for childbirth, any person who denies a woman the right to have an abortion is increasing the risk that the health of the woman will be endangered. By law, therefore, all abortion requests should be honored.

  10. Consent and assessment of capacity to decide or refuse treatment.

    Science.gov (United States)

    Simpson, Owena

    Consent protects the right of patients to decide what happens to them. Before any medical intervention, adults must give valid consent, which must be voluntary, informed and given free of undue influence. When consent is being obtained, patients must be informed about the intervention, why it is being done and its risks; information they are given must be recorded. Every effort should be made to explain the issues in terms that the patient can understand and by providing support and aids to communicate. Consent can be expressed, where patients say they consent or put it in writing, or implied, where a healthcare professional infers from their behaviour that they consent. While different types of consent are valid, some are evidence of stronger proof in court that valid consent has been given. Competent adults have the right to refuse treatment, regardless of the reasons they give for refusal and even if the refusal will result in death; clinicians must respect their decision. In some circumstances-such as when an unconscious person is admitted as an emergency-healthcare professionals can make decisions on behalf of patients, and must do so in patients' best interests.

  11. Delay and refusal of human papillomavirus vaccine for girls, national immunization survey-teen, 2010.

    Science.gov (United States)

    Dorell, Christina; Yankey, David; Jeyarajah, Jenny; Stokley, Shannon; Fisher, Allison; Markowitz, Lauri; Smith, Philip J

    2014-03-01

    Human papillomavirus (HPV) vaccine coverage among girls is low. We used data reported by parents of 4103 girls, 13 to 17 years old, to assess associations with, and reasons for, delaying or refusing HPV vaccination. Sixty-nine percent of parents neither delayed nor refused vaccination, 11% delayed only, 17% refused only, and 3% both delayed and refused. Eighty-three percent of girls who delayed only, 19% who refused only, and 46% who both delayed and refused went on to initiate the vaccine series or intended to initiate it within the next 12 months. A significantly higher proportion of parents of girls who were non-Hispanic white, lived in households with higher incomes, and had mothers with higher education levels, delayed and/or refused vaccination. The most common reasons for nonvaccination were concerns about lasting health problems from the vaccine, wondering about the vaccine's effectiveness, and believing the vaccine is not needed.

  12. Permafrost thaw and fire history: implications of boreal tree cover changes on land surface properties and turbulent energy fluxes in the Taiga Plains, Canada

    Science.gov (United States)

    Sonnentag, Oliver; Helbig, Manuel; Payette, Fanny; Wischnewski, Karoline; Kljun, Natascha; Chasmer, Laura; Pappas, Christoforos; Detto, Matteo; Baltzer, Jennifer; Quinton, William; Marsh, Philip

    2016-04-01

    . The spatial heterogeneities within the eddy covariance flux footprints (forest/wetland vs. wetland) were resolved with a two-dimensional footprint model parameterized with various remote sensing data sets. Our results suggest that an increasing coverage of wetlands at the expense of forests reduces ga and thus the efficiency of the land surface to transfer heat to the atmosphere. At the same time gs is increased and thus more moisture is lost to the atmosphere from saturated wetland surfaces. The alteration of bulk transfer land surface properties lead to drastic decreases in Bowen ratios by reducing H and increasing LE with increasing coverage of wetlands. The most pronounced contrasts between forests and wetlands are observed in H during the late snow cover period in April. We used a similar set of eddy covariance flux measurements made concurrently at Havikpak Creek (68°19' N; 133°31' W) and Trail Valley Creek (68°44' N; 133°26' W), a boreal forest and a nearby tundra site in the boreal-tundra ecotone, respectively, as a first-order proxy for potentially increasing PTC under more stable permafrost conditions in contrast to Scotty Creek. Preliminary results indicate trends in ga, gs, H and LE opposite to those observed at Scotty Creek between forests and wetlands. Our study demonstrates diverging implications of boreal tree cover changes on land surface properties and turbulent energy fluxes, thus on regional climate system feedback directions and strengths, as a function of permafrost conditions and fire history.

  13. Energy Design Analysis and Evaluation of a Proposed Air Rescue and Fire Fighting Administration Building for Teterboro Airport

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.; Pless, S.; Talbert, B.; Deru, M.; Torcellini, P.

    2003-07-01

    A new/proposed building for the Teterboro Airport was selected as a case study for High Performance Building Initiative research efforts. This report documents research-level energy analysis conducted on the Teterboro Airport building during predesign and design phases of the project.

  14. International seminar on biomass and fossil fuels co-firing in power plants and heating plants in Europe; Seminaire international sur la cocombustion de biomasse et d'energies fossiles dans les centrales electriques et les chaufferies en Europe

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The aim of the European commission which has fixed to 12% the share of renewable energies in the total energy consumption up to 2010, is to develop the biomass sector. Co-firing is a solution that allows to increase significantly the use of biomass because it does not require important investments. Today, about 150 power plants in Europe use co-firing. An Altener project named 'Cofiring' has ben settled in order to bring together and analyze the European experience in this domain and to sustain and rationalize the design of future projects. The conclusions of this study, coordinated by VTT Energy and which involves CARMEN (Germany), CBE (Portugal), the Danish centre for landscape and planning, ITEBE (France), KOBA (Italy), SLU (Sweden), and EVA (Austria), were presented during this international seminar. (J.S.)

  15. Adaptive monitoring of emissions in energy boilers using self-organizing maps: An application to a biomass-fired CFB (circulating fluidized bed)

    International Nuclear Information System (INIS)

    Liukkonen, M.; Hiltunen, T.

    2014-01-01

    Improvement of energy efficiency, reduction of operating costs, and reduction of harmful emissions released into the atmosphere are issues of major concern in modern energy plants. While air emissions have to be restricted due to tightening environmental legislation, at the same time it is ever more important to be able to respond quickly to any changes in the load demand or fuel quality. As unpredictability increases with changing fuel quality and more complex operational strategies, undesired phenomena such as increased emission release rates may become more likely. Therefore, it is crucial that emission monitoring systems are able to adapt to varying conditions, and advanced methodologies are needed for monitoring and decision-support. In this paper a novel approach for advanced monitoring of emissions in CFB (circulating fluidized bed) boilers is described. In this approach a model based on SOM (self-organizing maps) is updated regularly to respond to the prevailing condition of the boiler. After creating each model a new set of measurements is input to the system, and the current state of the process is determined using vector distance calculation. Finally, the system evaluates the current condition and may alert if a preset limit defined for each emission component is exceeded. - Highlights: • An adaptive monitoring approach based on self-organizing maps is presented. • The system can monitor the current state of a combustion process and its emissions. • The system is designed to alert when the preset limits defined for emissions are exceeded. • Due to regular updating routine the system is able to adapt to changing conditions. • The application is demonstrated using data from a biomass-fired energy boiler

  16. Exploratory Studies Facility Subsurface Fire Hazards Analysis

    International Nuclear Information System (INIS)

    Logan, Richard C.

    2002-01-01

    The primary objective of this Fire Hazard Analysis (FHA) is to confirm the requirements for a comprehensive fire and related hazards protection program for the Exploratory Studies Facility (ESF) are sufficient to minimize the potential for: The occurrence of a fire or related event; A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees, the public or the environment; Vital U.S. Department of Energy (DOE) programs suffering unacceptable interruptions as a result of fire and related hazards; Property losses from a fire and related events exceeding limits established by DOE; and Critical process controls and safety class systems being damaged as a result of a fire and related events

  17. Exploratory Studies Facility Subsurface Fire Hazards Analysis

    International Nuclear Information System (INIS)

    Kubicek, J. L.

    2001-01-01

    The primary objective of this Fire Hazard Analysis (FHA) is to confirm the requirements for a comprehensive fire and related hazards protection program for the Exploratory Studies Facility (ESF) are sufficient to minimize the potential for: (1) The occurrence of a fire or related event. (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees, the public or the environment. (3) Vital US. Department of Energy (DOE) programs suffering unacceptable interruptions as a result of fire and related hazards. (4) Property losses from a fire and related events exceeding limits established by DOE. (5) Critical process controls and safety class systems being damaged as a result of a fire and related events

  18. Pigments which reflect infrared radiation from fire

    Science.gov (United States)

    Berdahl, Paul H.

    1998-01-01

    Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer (.mu.m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 .mu.m or, for cool smoky fires, about 2 .mu.m to about 16 .mu.m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 .mu.m to about 2 .mu.m and thin leafing aluminum flake pigments.

  19. Model-based energy efficiency monitoring of gas-fired furnaces; Modellgestuetztes Energieeffizienz-Monitoring an Industriefeuerungen

    Energy Technology Data Exchange (ETDEWEB)

    Gose, Sven; Schult, Stefan; Sternberg, Jost [SAACKE GmbH, Bremen (Germany)

    2011-09-15

    This paper first describes the losses and the saving potential of heat generation plants and contrasts the usual characteristic numbers for assessing the energy efficiency. As these numbers describe a discontinuous process often only insufficiently, the characteristic number ''fuel efficiency'' is introduced. This number can only be calculated through a continuous monitoring system. The benefits of such a monitoring system are demonstrated by an example. (orig.)

  20. Alternative approach for fire suppression of class A, B and C fires in gloveboxes

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberger, Mark S [Los Alamos National Laboratory; Tsiagkouris, James A [Los Alamos National Laboratory

    2011-02-10

    Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, is capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.

  1. United States Department of Energy's reactor core protection evaluation methodology for fires at RBMK and VVER nuclear power plants. Revision 1

    International Nuclear Information System (INIS)

    1997-06-01

    This document provides operators of Soviet-designed RBMK (graphite moderated light water boiling water reactor) and VVER (pressurized light water reactor) nuclear power plants with a systematic Methodology to qualitatively evaluate plant response to fires and to identify remedies to protect the reactor core from fire-initiated damage

  2. Fire Behavior (FB)

    Science.gov (United States)

    Robert E. Keane

    2006-01-01

    The Fire Behavior (FB) method is used to describe the behavior of the fire and the ambient weather and fuel conditions that influence the fire behavior. Fire behavior methods are not plot based and are collected by fire event and time-date. In general, the fire behavior data are used to interpret the fire effects documented in the plot-level sampling. Unlike the other...

  3. Fire Symfonier

    DEFF Research Database (Denmark)

    Nielsen, Svend Hvidtfelt

    2009-01-01

    sidste fire symfonier. Den er måske snarere at opfatte som et præludium til disse. At påstå, at symfonierne fra Holmboes side er planlagt til at være beslægtede, ville være at gå for vidt. Alene de 26 år, der skiller den 10. fra den 13., gør påstanden - i bedste fald - dubiøs. Når deres udformning...... udkrystallisering som i de sidste små 30 år af hans virke har afkastet disse fire variationer over en grundlæggende central holmboesk fornemmelse for form, melodi, klang og rytme. Denne oplevelse har fået mig til at udforske symfonierne, for at finde til bunds i dette holmboeske fællestræk, som jeg mener her står...

  4. A novel syngas-fired hybrid heating source for solar-thermal applications: Energy and exergy analysis

    International Nuclear Information System (INIS)

    Pramanik, Santanu; Ravikrishna, R.V.

    2016-01-01

    Highlights: • Biomass-derived syngas as a hybrid energy source for solar thermal power plants. • A novel combustor concept using rich-catalytic and MILD combustion technologies. • Hybrid energy source for a solar-driven supercritical CO 2 -based Brayton cycle. • Comprehensive energetic and exergetic analysis of the combined system. - Abstract: A hybrid heating source using biomass-derived syngas is proposed to enable continuous operation of standalone solar thermal power generation plants. A novel, two-stage, low temperature combustion system is proposed that has the potential to provide stable combustion of syngas with near-zero NO x emissions. The hybrid heating system consists of a downdraft gasifier, a two-stage combustion system, and other auxiliaries. When integrated with a solar cycle, the entire system can be referred to as the integrated gasification solar combined cycle (IGSCC). The supercritical CO 2 Brayton cycle (SCO 2 ) is selected for the solar cycle due to its high efficiency. The thermodynamic performance evaluation of the individual unit and the combined system has been conducted from both energy and exergy considerations. The effect of parameters such as gasification temperature, biomass moisture content, equivalence ratio, and pressure ratio is studied. The efficiency of the IGSCC exhibited a non-monotonic behavior. A maximum thermal efficiency of 36.5% was achieved at an overall equivalence ratio of 0.22 and pressure ratio of 2.75 when the gasifier was operating at T g = 1073 K with biomass containing 20% moisture. The efficiency increased to 40.8% when dry biomass was gasified at a temperature of 973 K. The exergy analysis revealed that the maximum exergy destruction occurred in the gasification system, followed by the combustion system, SCO 2 cycle, and regenerator. The exergy analysis also showed that 8.72% of the total exergy is lost in the exhaust; however, this can be utilized for drying of the biomass.

  5. Refusal of medical treatment in the pediatric emergency service: analysis of reasons and aspects.

    Science.gov (United States)

    Gündüz, Ramiz Coşkun; Halil, Halit; Gürsoy, Cüneyt; Çifci, Atilla; Özgün, Seher; Kodaman, Tuğba; Sönmez, Mehtap

    2014-01-01

    Refusal of treatment for acutely ill children is still an important problem in the emergency service. When families refuse medical treatment for their acutely ill children, healthcare professionals may attempt to provide information and negotiate with the family concerning treatment refusal and its possible adverse outcomes, and request consent for refusal of medical treatment. There is insufficient data about refusal of treatment in our country. The purpose of this study was to analyze the causes of treatment refusal in the pediatric emergency service. We collected data recorded on informed consent forms. During a 2-year-study period, 215 patients refused treatment recommended by acute health care professionals. The majorty of patients were in the 0-2 year age group. Hospitalization was the type of treatment most commonly refused; restrictions regarding family members staying with their children during hospitalization and admission to another hospital were the major reasons for refusal of treatment. Clarifying the reasons for treatment refusal may help us to overcome deficiencies, improve conditions, resolve problems and build confidence between healthcare providers and service users, increasing users' satisfaction in the future.

  6. Browns Ferry fire

    International Nuclear Information System (INIS)

    Harkleroad, J.R.

    1983-01-01

    A synopsis of the March 22, 1975 fire at Browns Ferry Nuclear Plant is discussed. Emphasis is placed on events prior to and during the fire. How the fire started, fire fighting activities, fire and smoke development, and restoration activities are discussed

  7. Gas fired heat pumps

    International Nuclear Information System (INIS)

    Seifert, M.

    2006-01-01

    The condensing gas boiler is now state of the art and there is no more room for improvement in performance, technically speaking. The next logical step to improve the overall efficiency is to exploit ambient heat in combination with the primary source of energy, natural gas. That means using natural-gas driven heat pumps and gas-fired heat pumps. Based on this, the Swiss Gas Industry decided to set up a practical test programme enjoying a high priority. The aim of the project 'Gas-fired heat pump practical test' is to assess by field tests the characteristics and performance of the foreign serial heat pumps currently on the market and to prepare and promote the introduction on the market place of this sustainable natural-gas technology. (author)

  8. NREL Evaluates Performance of Hydraulic Hybrid Refuse Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    This highlight describes NREL's evaluation of the in-service performance of 10 next-generation hydraulic hybrid refuse vehicles (HHVs), 8 previous-generation (model year 2013) HHVs, and 8 comparable conventional diesel vehicles operated by Miami-Dade County's Public Works and Waste Management Department in southern Florida. Launched in March 2015, the on-road portion of this 12-month evaluation focuses on collecting and analyzing vehicle performance data - fuel economy, maintenance costs, and drive cycles - from the HHVs and the conventional diesel vehicles. The fuel economy of heavy-duty vehicles, such as refuse trucks, is largely dependent on the load carried and the drive cycles on which they operate. In the right applications, HHVs offer a potential fuel-cost advantage over their conventional counterparts. This advantage is contingent, however, on driving behavior and drive cycles with high kinetic intensity that take advantage of regenerative braking. NREL's evaluation will assess the performance of this technology in commercial operation and help Miami-Dade County determine the ideal routes for maximizing the fuel-saving potential of its HHVs. Based on the field data, NREL will develop a validated vehicle model using the Future Automotive Systems Technology Simulator, also known as FASTSim, to study the impacts of route selection and other vehicle parameters. NREL is also analyzing fueling and maintenance data to support total-cost-of-ownership estimations and forecasts. The study aims to improve understanding of the overall usage and effectiveness of HHVs in refuse operation compared to similar conventional vehicles and to provide unbiased technical information to interested stakeholders.

  9. Stop on construction of fast breeder at Kalkar refused

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The application of a plaintiff was refused by the verdict of the High Court for North Rhine-Westphalia of 16.6.1978, which would have restored the delaying effect of his application against the defendant Minister of the Land (his opponent) on the first part licence of the Kalkar nuclear power station. The plaintiff had to bear the costs of the proceedings, including extra legal costs of the co-defendant nuclear power company. The value of the object of the case was set at DM 10,000. This means that construction can continue. The most important reasons for turning down the application are given. (orig./HP) [de

  10. Vaccination refusal: ethics, individual rights, and the common good.

    Science.gov (United States)

    Schwartz, Jason L; Caplan, Arthur L

    2011-12-01

    Among the obstacles to the success of vaccination programs is the apparent recent increase in hesitancy and outright resistance to the recommended vaccination schedule by some parents and patients. This article reviews the spectrum of patient or parental attitudes that may be described as vaccine refusal, explores related ethical considerations in the context of the doctor-patient relationship and public health, and evaluates the possible responses of physicians when encountering resistance to vaccination recommendations. Health care providers should view individuals hesitant about or opposed to vaccines not as frustrations or threats to public health, but as opportunities to educate and inform. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Psychotropic Medication Refusal: Reasons and Patients′ Perception at a Secure Forensic Psychiatric Treatment Centre

    Directory of Open Access Journals (Sweden)

    Olajide O Adelugba

    2016-01-01

    Full Text Available Poor adherence to prescribed medication regimens can undermine the effectiveness of medications. This study was conducted to determine the demographic profile of forensic psychiatric inpatients refusing medications and to identify the reasons for refusal. Data were collected through interviews using a questionnaire including Drug Attitude Inventory-10. Medication refusal was more common among Aboriginals (68%, n = 34 than Caucasians (32%, n = 16 and was highest among the patients 21-30 years of age (44%, n = 22. Antisocial personality disorder and substance use disorder featured prominently among patients refusing medications. The main reasons for medication refusal were inconvenience (34%, n = 17 followed by side effects (22%, n = 11, ineffective medication (20%, n = 10, illness-related (16%, n = 8, and no reasons (8%, n = 6. Antipsychotic medications topped the list of the major classes of medications refused followed by Antidepressants and Mood Stabilizers.

  12. Refusal of Curative Radiation Therapy and Surgery Among Patients With Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Aizer, Ayal A., E-mail: aaaizer@partners.org [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Chen, Ming-Hui [Department of Statistics, University of Connecticut, Storrs, Connecticut (United States); Parekh, Arti [Boston University School of Medicine, Boston, Massachusetts (United States); Choueiri, Toni K. [Lank Center for Genitourinary Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Harvard Medical School, Boston, Massachusetts (United States); Hoffman, Karen E. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kim, Simon P. [Department of Urology, Mayo Clinic, Rochester, Minnesota (United States); Martin, Neil E. [Lank Center for Genitourinary Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Harvard Medical School, Boston, Massachusetts (United States); Hu, Jim C. [Department of Urology, University of California, Los Angeles, California (United States); Trinh, Quoc-Dien [Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Quebec (Canada); Nguyen, Paul L. [Lank Center for Genitourinary Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Harvard Medical School, Boston, Massachusetts (United States)

    2014-07-15

    Purpose: Surgery and radiation therapy represent the only curative options for many patients with solid malignancies. However, despite the recommendations of their physicians, some patients refuse these therapies. This study characterized factors associated with refusal of surgical or radiation therapy as well as the impact of refusal of recommended therapy on patients with localized malignancies. Methods and Materials: We used the Surveillance, Epidemiology, and End Results program to identify a population-based sample of 925,127 patients who had diagnoses of 1 of 8 common malignancies for which surgery and/or radiation are believed to confer a survival benefit between 1995 and 2008. Refusal of oncologic therapy, as documented in the SEER database, was the primary outcome measure. Multivariable logistic regression was used to investigate factors associated with refusal. The impact of refusal of therapy on cancer-specific mortality was assessed with Fine and Gray's competing risks regression. Results: In total, 2441 of 692,938 patients (0.4%) refused surgery, and 2113 of 232,189 patients (0.9%) refused radiation, despite the recommendations of their physicians. On multivariable analysis, advancing age, decreasing annual income, nonwhite race, and unmarried status were associated with refusal of surgery, whereas advancing age, decreasing annual income, Asian American race, and unmarried status were associated with refusal of radiation (P<.001 in all cases). Refusal of surgery and radiation were associated with increased estimates of cancer-specific mortality for all malignancies evaluated (hazard ratio [HR], 2.80, 95% confidence interval [CI], 2.59-3.03; P<.001 and HR 1.97 [95% CI, 1.78-2.18]; P<.001, respectively). Conclusions: Nonwhite, less affluent, and unmarried patients are more likely to refuse curative surgical and/or radiation-based oncologic therapy, raising concern that socioeconomic factors may drive some patients to forego potentially life

  13. Refusal of Curative Radiation Therapy and Surgery Among Patients With Cancer

    International Nuclear Information System (INIS)

    Aizer, Ayal A.; Chen, Ming-Hui; Parekh, Arti; Choueiri, Toni K.; Hoffman, Karen E.; Kim, Simon P.; Martin, Neil E.; Hu, Jim C.; Trinh, Quoc-Dien; Nguyen, Paul L.

    2014-01-01

    Purpose: Surgery and radiation therapy represent the only curative options for many patients with solid malignancies. However, despite the recommendations of their physicians, some patients refuse these therapies. This study characterized factors associated with refusal of surgical or radiation therapy as well as the impact of refusal of recommended therapy on patients with localized malignancies. Methods and Materials: We used the Surveillance, Epidemiology, and End Results program to identify a population-based sample of 925,127 patients who had diagnoses of 1 of 8 common malignancies for which surgery and/or radiation are believed to confer a survival benefit between 1995 and 2008. Refusal of oncologic therapy, as documented in the SEER database, was the primary outcome measure. Multivariable logistic regression was used to investigate factors associated with refusal. The impact of refusal of therapy on cancer-specific mortality was assessed with Fine and Gray's competing risks regression. Results: In total, 2441 of 692,938 patients (0.4%) refused surgery, and 2113 of 232,189 patients (0.9%) refused radiation, despite the recommendations of their physicians. On multivariable analysis, advancing age, decreasing annual income, nonwhite race, and unmarried status were associated with refusal of surgery, whereas advancing age, decreasing annual income, Asian American race, and unmarried status were associated with refusal of radiation (P<.001 in all cases). Refusal of surgery and radiation were associated with increased estimates of cancer-specific mortality for all malignancies evaluated (hazard ratio [HR], 2.80, 95% confidence interval [CI], 2.59-3.03; P<.001 and HR 1.97 [95% CI, 1.78-2.18]; P<.001, respectively). Conclusions: Nonwhite, less affluent, and unmarried patients are more likely to refuse curative surgical and/or radiation-based oncologic therapy, raising concern that socioeconomic factors may drive some patients to forego potentially life

  14. Fire Ant Bites

    Science.gov (United States)

    ... Favorite Name: Category: Share: Yes No, Keep Private Fire Ant Bites Share | Fire ants are aggressive, venomous insects that have pinching ... across the United States, even into Puerto Rico. Fire ant stings usually occur on the feet or ...

  15. Fire safety at home

    Science.gov (United States)

    ... over the smoke alarm as needed. Using a fire extinguisher can put out a small fire to keep it from getting out of control. Tips for use include: Keep fire extinguishers in handy locations, at least one on ...

  16. Crown Fire Potential

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Crown fire potential was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The...

  17. National Fire Protection Association

    Science.gov (United States)

    ... closed NFPA Journal® NFPA Journal® Update (newsletter) Fire Technology ... die from American home fires, and another 13,000 are injured each year. This is the story of fire that the statistics won't show ...

  18. Predictors of intensive care unit refusal in French intensive care units: a multiple-center study.

    Science.gov (United States)

    Garrouste-Orgeas, Maité; Montuclard, Luc; Timsit, Jean-François; Reignier, Jean; Desmettre, Thibault; Karoubi, Philippe; Moreau, Delphine; Montesino, Laurent; Duguet, Alexandre; Boussat, Sandrine; Ede, Christophe; Monseau, Yannick; Paule, Thierry; Misset, Benoit; Carlet, Jean

    2005-04-01

    To identify factors associated with granting or refusing intensive care unit (ICU) admission, to analyze ICU characteristics and triage decisions, and to describe mortality in admitted and refused patients. Observational, prospective, multiple-center study. Four university hospitals and seven primary-care hospitals in France. None. Age, underlying diseases (McCabe score and Knaus class), dependency, hospital mortality, and ICU characteristics were recorded. The crude ICU refusal rate was 23.8% (137/574), with variations from 7.1% to 63.1%. The reasons for refusal were too well to benefit (76/137, 55.4%), too sick to benefit (51/137, 37.2%), unit too busy (9/137, 6.5%), and refusal by the family (1/137). In logistic regression analyses, two patient-related factors were associated with ICU refusal: dependency (odds ratio [OR], 14.20; 95% confidence interval [CI], 5.27-38.25; p refused patients, and 1.03 (95% CI, 0.28-1.75) for later-admitted patients. ICU refusal rates varied greatly across ICUs and were dependent on both patient and organizational factors. Efforts to define ethically optimal ICU admission policies might lead to greater homogeneity in refusal rates, although case-mix variations would be expected to leave an irreducible amount of variation across ICUs.

  19. Toilet refusal syndrome in preschool children: do different subtypes exist?

    Science.gov (United States)

    Niemczyk, Justine; Equit, Monika; El Khatib, Diana; von Gontard, Alexander

    2014-03-01

    Toilet refusal syndrome (TRS) is a common, benign disorder in toddlers defined by the use of diapers and refusal of toilet for defaecation, but has not been described systematically in preschool children yet. The aim of the study was to analyse and identify possible subgroups of TRS. Retrospective analysis of all of the consecutive children with TRS presented as outpatients in a clinic for elimination disorders. Patients had received a detailed paediatric and child psychiatric assessment, including the Child Behavior Checklist questionnaire. Three typical case vignettes are presented of TRS with constipation, oppositional defiant disorder, and sibling rivalry. Twenty-five children (10 boys) with a mean age of 5.2 (3.4-7.3) years were included-representing 2.5% of all of the children (n = 1001) presented. They had high rates of constipation (60%) and elimination disorders (24%-44%). Child psychiatric International Classification of Diseases-10th Edition disorders were common (40%) and heterogeneous, with significantly more boys affected, but no differences between children with and without constipation. This study shows that TRS occurs also in older preschool (and even school) children. At this later age, it is associated with constipation and behavioural disorders. The case vignettes show differences in therapy and may represent different subgroups of TRS. TRS is associated with constipation, elimination disorders, and psychiatric disorders. Owing to this variety of comorbid disorders, different therapeutic approaches are needed. A general screening for behavioural symptoms is recommended.

  20. Constructive and Destructive Aspects of Refusal from Communication

    Directory of Open Access Journals (Sweden)

    Marianna A. Gulyaeva

    2016-12-01

    Full Text Available The article investigates the phenomenon of refusal from communication in terms of its positive and negative impact, both on the communicative process, and interpersonal relationships in general. It has been analyzed several aspects of the failure to communicate with positive communication position. The identification of constructive or destructive potential was carried out on the basis of three parameters such as productivity/ unproductive conflict resolution with the help of avoiding communication, the choice of an optimum way of non-communication and its role in the communication process on the basis of the functions performed by them. Failure to communicate is often perceived negatively and is considered an inefficient form of communication, so it does not allow to solve interpersonal conflicts. This article discusses the circumstances where refusal from communication advocates an effective way to avoid conflict. In situations where the termination of communication is inevitable, a fundamental factor for the positive, harmonious form of communication acts interrupting the communication process. Functioning in the communicative space, failure to communicate can either destroy an interaction and relationship between the partners, and regulate the communication process by guiding in the right direction, coordinating the behavior of communication.

  1. Abandoned coal mine refuse areas: their reclamation and use

    Energy Technology Data Exchange (ETDEWEB)

    Zellmer, S. D.; Carter, R. P.

    1977-01-01

    There are over 4,000 abandoned deep coal mine refuse areas in Illinois ranging in size from a few acres to as large as 160 acres. These sites produce quantities of pollutants which affect the environment, have no real land value, and are a scar on the landscape. The Staunton 1 Site Reclamation Demonstration Project addressess these problems. It also is developing and evaluating new cost-effective methods for reclaiming refuse areas of this type. The program involved determining the final land use for the site, development of detailed engineering plans and specifications for the reclamation effort, a prereclamation environmental inventory, and implementation. Post-construction evaluation is now in process to determine the effectiveness of the reclamation effort. Detailed investigations are being conducted to determine surface water quality improvement, the amount of suitable surface cover and amendments required for revegetation, and field evaluation of candidate vegetation species for revegetation. Other research is examining soil microbial populations, soil fauna reactions, and changes in surface material characteristics at the reclamation site. Surveys are being conducted on groundwater quality, effects on the aquatic ecosystem, and wildlife use of the area. An economic evaluation is underway to determine the cost effectiveness of the total effort and of individual reclamation procedures. Preliminary results from the first year's environmental evaluation of various method tested will be described in detail. An economic assessment, including cost effectiveness, of the first year's work is given.

  2. Refusal of implant supported mandibular overdentures by elderly patients.

    Science.gov (United States)

    Ellis, Janice S; Levine, Alissa; Bedos, Christophe; Mojon, Phillippe; Rosberger, Zeer; Feine, Jocelyne; Thomason, J Mark

    2011-03-01

      The aim of this study was to gain greater in-depth understanding of why elderly patients who are currently dissatisfied with conventional dentures decline implant treatment.   There is strong evidence from high-quality randomised controlled trials to support the use of implant-supported overdentures for the restoration of the edentulous mandible. However, whilst recruiting for randomised clinical trials, researchers have found that a high proportion of potential subjects decline participation, despite the removal of financial constraints.   The study adopted a qualitative approach to provide a rich and deep understanding of people's reasons for refusal. Data were collected through focus group interviews in a two-centre study based in Montreal, Canada and Newcastle, UK. A semi-structured interview schedule was used and iteratively developed as analysis identified themes from previous focus groups. Transcripts of focus groups were coded and emergent themes determined.   Two main themes emerged; patients' fear and anxiety (relating to the pain of surgery, complications of the procedure and immediate post-surgical denture use), and the appropriateness of the procedure in an elderly person.   Fears of pain, complications and social embarrassment, exacerbated by age, are important factors that help explain refusal of implants by elderly patients. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  3. Rationality, religion and refusal of treatment in an ambulance revisited.

    Science.gov (United States)

    McMahon-Parkes, Kate

    2013-09-01

    In their recent article, Erbay et al considered whether a seriously injured patient should be able to refuse treatment if the refusal was based on a (mis)interpretation of religious doctrine. They argued that in such a case 'what is important…is whether the teaching or philosophy used as a reference point has been in fact correctly perceived' (p 653). If it has not been, they asserted that this eroded the patient's capacity to make an autonomous decision and that therefore, in such cases, it is the role of the healthcare professional (HCP) to 'assist patients to think more clearly and rationally' (p 653). There are, however, a number of problems with the reasons why Erbay et al suggest we should help patients to rationalise their decisions and how HCPs should go about this. In this article, the author explores some of their main arguments regarding consent and rationality (particularly in relation to religious beliefs), as well as Erbay et al's normative claim that HCPs have an obligation to promote autonomy by helping patients to come to a 'rational' decision. Ultimately, the author agrees that the (temporary) solution to the dilemma presented in this scenario (which was to insert an intravenous cannula into the patient in order to allow an infusion of fluids in the event that he changed his mind) seemed both pragmatic and ethically permissible. However, it is suggested that the arguments which underpin this conclusion in Erbay et al's article are largely unsound.

  4. Fire danger rating over Mediterranean Europe based on fire radiative power derived from Meteosat

    Science.gov (United States)

    Pinto, Miguel M.; DaCamara, Carlos C.; Trigo, Isabel F.; Trigo, Ricardo M.; Feridun Turkman, K.

    2018-02-01

    We present a procedure that allows the operational generation of daily forecasts of fire danger over Mediterranean Europe. The procedure combines historical information about radiative energy released by fire events with daily meteorological forecasts, as provided by the Satellite Application Facility for Land Surface Analysis (LSA SAF) and the European Centre for Medium-Range Weather Forecasts (ECMWF). Fire danger is estimated based on daily probabilities of exceedance of daily energy released by fires occurring at the pixel level. Daily probability considers meteorological factors by means of the Canadian Fire Weather Index (FWI) and is estimated using a daily model based on a generalized Pareto distribution. Five classes of fire danger are then associated with daily probability estimated by the daily model. The model is calibrated using 13 years of data (2004-2016) and validated against the period of January-September 2017. Results obtained show that about 72 % of events releasing daily energy above 10 000 GJ belong to the extreme class of fire danger, a considerably high fraction that is more than 1.5 times the values obtained when using the currently operational Fire Danger Forecast module of the European Forest Fire Information System (EFFIS) or the Fire Risk Map (FRM) product disseminated by the LSA SAF. Besides assisting in wildfire management, the procedure is expected to help in decision making on prescribed burning within the framework of agricultural and forest management practices.

  5. Fire danger rating over Mediterranean Europe based on fire radiative power derived from Meteosat

    Directory of Open Access Journals (Sweden)

    M. M. Pinto

    2018-02-01

    Full Text Available We present a procedure that allows the operational generation of daily forecasts of fire danger over Mediterranean Europe. The procedure combines historical information about radiative energy released by fire events with daily meteorological forecasts, as provided by the Satellite Application Facility for Land Surface Analysis (LSA SAF and the European Centre for Medium-Range Weather Forecasts (ECMWF. Fire danger is estimated based on daily probabilities of exceedance of daily energy released by fires occurring at the pixel level. Daily probability considers meteorological factors by means of the Canadian Fire Weather Index (FWI and is estimated using a daily model based on a generalized Pareto distribution. Five classes of fire danger are then associated with daily probability estimated by the daily model. The model is calibrated using 13 years of data (2004–2016 and validated against the period of January–September 2017. Results obtained show that about 72 % of events releasing daily energy above 10 000 GJ belong to the extreme class of fire danger, a considerably high fraction that is more than 1.5 times the values obtained when using the currently operational Fire Danger Forecast module of the European Forest Fire Information System (EFFIS or the Fire Risk Map (FRM product disseminated by the LSA SAF. Besides assisting in wildfire management, the procedure is expected to help in decision making on prescribed burning within the framework of agricultural and forest management practices.

  6. New energy vision for Ginoza village. Fiscal 2000 survey report on new energy vision formulation project for Ginoza village; Ginozason shin energy vision. 2000 nendo Ginozason shin energy vision sakutei nado jigyo chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    A new energy vision has been formulated for Ginoza village, Okinawa Prefecture, for the realization of symbiosis with nature. It is a 5,000-strong entirely farming village situated along the eastern coast at the middle of the main island of the Ryukyus, with energy consumption of 9,982 kl in terms of crude oil in fiscal 1999. The results of activities in this connection are summarized in six chapters, which are (1) the state of the village and new energy, (2) current state of energy supply/demand and outlook for the future, (3) existing amount of new energy, (4) trends of types of new energy under study, (5) feasibility of new energy introduction, and (6) Ginoza village's new energy vision. Chapter (6) is constituted of the general principles of new energy introduction into Ginoza village and a long-term vision of new energy introduction for each field, and discusses the introducible types which are photovoltaic power generation, wind power generation, small scale hybrid power source systems, fuel cells, natural gas fired cogeneration, refuse fueled power generation, and clean energy vehicles. (NEDO)

  7. FIRE CHARACTERISTICS FOR ADVANCED MODELLING OF FIRES

    OpenAIRE

    Otto Dvořák

    2016-01-01

    This paper summarizes the material and fire properties of solid flammable/combustible materials /substances /products, which are used as inputs for the computer numerical fire models. At the same time it gives the test standards for their determination.

  8. Mine-fire diagnostics applied to the Carbondale, Pennsylvania mine-fire site. Rept. of Investigations/1992

    International Nuclear Information System (INIS)

    Kim, A.G.; Justin, T.R.; Miller, J.F.

    1992-01-01

    The U.S. Bureau of Mines applied its mine fire diagnostic method to an abandoned anthracite mine fire site in Carbondale, Lackawanna County, PA. The technique to locate fires in abandoned coal mines and coal refuse piles includes the determination of hydrocarbon concentrations in mine gases, the imposition of an underground gas flow direction, and use of a surface mapping method, to define heated and cold zones in underground coal strata. The heated zones at Carbondale were characterized by elevated methane concentrations. The results of 25 communication tests were analyzed to define 2 large (approximately 100 by 250 ft) and 5 small, isolated heated zones. An approximate correlation existed between the location of the heated zones and areas of anomalous snow melt. The correlation between the results of the diagnostic test and subsurface temperatures was not significant

  9. Boreal Forest Fire Cools Climate

    Science.gov (United States)

    Randerson, J. T.; Liu, H.; Flanner, M.; Chambers, S. D.; Harden, J. W.; Hess, P. G.; Jin, Y.; Mack, M. C.; Pfister, G.; Schuur, E. A.; Treseder, K. K.; Welp, L. R.; Zender, C. S.

    2005-12-01

    We report measurements, modeling, and analysis of carbon and energy fluxes from a boreal forest fire that occurred in interior Alaska during 1999. In the first year after the fire, ozone production, atmospheric aerosol loading, greenhouse gas emissions, soot deposition, and decreases in summer albedo contributed to a positive annual radiative forcing (RF). These effects were partly offset by an increase in fall, winter, and spring albedo from reduced canopy cover and increased exposure of snow-covered surfaces. The atmospheric lifetime of aerosols and ozone and are relatively short (days to months). The radiative effects of soot on snow are also attenuated rapidly from the deposition of fresh snow. As a result, a year after the fire, only two classes of RF mechanisms remained: greenhouse gas emissions and post-fire changes in surface albedo. Summer albedo increased rapidly in subsequent years and was substantially higher than unburned control areas (by more than 0.03) after 4 years as a result of grass and shrub establishment. Satellite measurements from MODIS of other interior Alaska burn scars provided evidence that elevated levels of spring and summer albedo (relative to unburned control areas) persisted for at least 4 decades after fire. In parallel, our chamber, eddy covariance, and biomass measurements indicated that the post-fire ecosystems switch from a source to a sink within the first decade. Taken together, the extended period of increased spring and summer albedo and carbon uptake of intermediate-aged stands appears to more than offset the initial warming pulse caused by fire emissions, when compared using the RF concept. This result suggests that management of forests in northern countries to suppress fire and preserve carbon sinks may have the opposite effect on climate as that intended.

  10. Evaluation of fire probabilistic safety assessment for a PWR plant

    International Nuclear Information System (INIS)

    Wu, C.H.; Lin, T.J.; Kao, T.M.

    2001-01-01

    The internal fire analysis of the level 1 power operation probability safety assessment (PSA) for Maanshan (PWR) Nuclear Power Plant (MNPP) was updated. The fire analysis adopted a scenario-based PSA approach to systematically evaluate fire and smoke hazards and their associated risk impact to MNPP. The result shows that the core damage frequency (CDF) due to fire is about six times lower than the previous one analyzed by the Atomic Energy Council (AEC), Republic of China in 1987. The plant model was modified to reflect the impact of human events and recovery actions during fire. Many tabulated EXCEL spread-sheets were used for evaluation of the fire risk. The fire-induced CDF for MNPP is found to be 2.1 E-6 per year in this study. The relative results of the fire analysis will provide the bases for further risk-informed fire protection evaluation in the near future. (author)

  11. Fire hazards analysis for the uranium oxide (UO3) facility

    International Nuclear Information System (INIS)

    Wyatt, D.M.

    1994-01-01

    The Fire Hazards Analysis (FHA) documents the deactivation end-point status of the UO 3 complex fire hazards, fire protection and life safety systems. This FHA has been prepared for the Uranium Oxide Facility by Westinghouse Hanford Company in accordance with the criteria established in DOE 5480.7A, Fire Protection and RLID 5480.7, Fire Protection. The purpose of the Fire Hazards Analysis is to comprehensively and quantitatively assess the risk from a fire within individual fire areas in a Department of Energy facility so as to ascertain whether the objectives stated in DOE Order 5480.7, paragraph 4 are met. Particular attention has been paid to RLID 5480.7, Section 8.3, which specifies the criteria for deactivating fire protection in decommission and demolition facilities

  12. Fire and fire ecology: Concepts and principles

    Science.gov (United States)

    Mark A. Cochrane; Kevin C. Ryan

    2009-01-01

    Fire has been central to terrestrial life ever since early anaerobic microorganisms poisoned the atmosphere with oxygen and multicellular plant life moved onto land. The combination of fuels, oxygen, and heat gave birth to fire on Earth. Fire is not just another evolutionary challenge that life needed to overcome, it is, in fact, a core ecological process across much...

  13. Remote sensing fire and fuels in southern California

    Science.gov (United States)

    Philip Riggan; Lynn Wolden; Bob Tissell; David Weise; J. Coen

    2011-01-01

    Airborne remote sensing at infrared wavelengths has the potential to quantify large-fire properties related to energy release or intensity, residence time, fuel-consumption rate, rate of spread, and soil heating. Remote sensing at a high temporal rate can track fire-line outbreaks and acceleration and spotting ahead of a fire front. Yet infrared imagers and imaging...

  14. Central Nervous System Disease, Education, and Race Impact Radiation Refusal in Pediatric Cancer Patients.

    Science.gov (United States)

    Patel, Chirayu G; Stavas, Mark; Perkins, Stephanie; Shinohara, Eric T

    2017-07-01

    To investigate the determinants of radiation therapy refusal in pediatric cancer, we used the Surveillance, Epidemiology, and End Results registry to identify 24,421 patients who met the eligibility criteria, diagnosed between 1974 and 2012. Patients had any stage of cancer, were aged 0 to 19, and received radiation therapy or refused radiation therapy when it was recommended. One hundred twenty-eight patients (0.52%) refused radiation therapy when it was recommended. Thirty-two percent of patients who refused radiation therapy ultimately died from their cancer, at a median of 7 months after diagnosis (95% confidence interval, 3-11 mo), as compared with 29.0% of patients who did not refuse radiation therapy died from their cancer, at a median of 17 months after diagnosis (95% confidence interval, 17-18 mo). On multivariable analysis, central nervous system (CNS) site, education, and race were associated with radiation refusal. The odds ratio for radiation refusal for patients with CNS disease was 1.62 (P=0.009) as compared with patients without CNS disease. For patients living in a county with ≥10% residents having less than ninth grade education, the odds ratio for radiation refusal was 1.71 (P=0.008) as compared with patients living in a county with education. Asian, Pacific Islander, Alaska Native, and American Indian races had an odds ratio of 2.12 (P=0.002) for radiation refusal as compared with black or white race. Although the radiation refusal rate in the pediatric cancer population is low, we show that CNS site, education level, and race are associated with a significant difference in radiation refusal.

  15. Perceived Quality of Informed Refusal Process: A Cross-Sectional Study from Iranian Patients' Perspectives.

    Science.gov (United States)

    Farzandipour, Mehrdad; Sheikhtaheri, Abbas; Sadeqi Jabali, Monireh

    2015-12-01

    Patients have the right to refuse their treatment; however, this refusal should be informed. We evaluated the quality of the informed refusal process in Iranian hospitals from patients' viewpoints. To this end, we developed a questionnaire that covered four key aspects of the informed refusal process including; information disclosure, voluntariness, comprehension, and provider-patient relationship. A total of 284 patients who refused their treatment from 12 teaching hospitals in the Isfahan Province, Iran, were recruited and surveyed to produce a convenience sample. Patients' perceptions about the informed refusal process were scored and the mean scores of the four components were calculated. The findings showed that the practice of information disclosure (9.6 ± 6.4 out of 22 points) was perceived to be moderate, however, comprehension (2.3 ± 1.4 out of 4 points), voluntariness (8.7 ± 1.5 out of 12 points) and provider-patient relationship (10.2 ± 5.2 out of 16 points) were perceived to be relatively good. We found that patients, who refused their care before any treatment had commenced, reported a lower quality of information disclosure and voluntariness. Patients informed by nurses and those who had not had a previous related admission, reported lower scores for comprehension and relationship. In conclusion, the process of obtaining informed refusal was relatively satisfactory except for levels of information disclosure. To improve current practices, Iranian patients need to be better informed about; different treatment options, consequences of treatment refusal, costs of not continuing treatment and follow-ups after refusal. Developing more informative refusal forms is needed. © 2014 John Wiley & Sons Ltd.

  16. Biomass CFB gasifier connected to a 350 MW{sub t}h steam boiler fired with coal and natural gas - THERMIE demonstration project in Lahti in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, J. [Foster Wheeler Energia Oy, Varkaus (Finland). Varkaus Global New Products

    1997-12-31

    The successful experience in developing the advanced Foster Wheeler Energi Oy`s (former Ahlstroem Pyropower) Circulating Fluidized Bed combustion system subsequently led to the development of the CFB gasification technology in the early 1980s. The driving force for the developing work was the dramatic increase in oil price during the oil crises. The primary advantage of CFB gasification technology is that the it enables the substitution of expensive fuels e.g. oil or gas with cheap solid fuels. These cheap fuels are typically different types of waste woods, bark or other biofuels. In the CFB gasifier these solid fuels are converted to gaseous fuel which can be used instead of other expensive fuels. In some cases this also solves a waste disposal problem, providing a secondary economic and environmental benefit. Foster Wheeler Energia Oy has supplied four commercial scale atmospheric CFB gasifiers in the mid 80s to the pulp and paper industry with capacities from 17 to 35 MW based on fuel input. These applications utilize waste wood as feedstock and the units are still successfully operation today. Lahden Laempoevoima Oy is a Finnish power company producing power and district heat for the city of Lahti. The company is 50 % owned by the city of Lahti and 50 % by Imatran Voima Oy, which is the largest utility power company in Finland. Lahden Laempoevoima Oy operates the Kymijaervi power plant locating nearby the city of Lahti in Southern Finland. To keep the energy prices as low as possible, Lahden Laempoevoima is continuously looking for the most economical fuel sources, and simultaneously, trying to improve the environmental acceptability of the energy production. At the moment, about 300 GWh/a different type of biofuels and refuse fuels are available in the Lahti area. On an annual basis, the available amount of biofuels and refuse fuels is enough to substitute for about 15 % of the fuels burned in the main boiler equalling max 30 % of coal. The aim in this Lahden

  17. Biomass CFB gasifier connected to a 350 MW{sub t}h steam boiler fired with coal and natural gas - THERMIE demonstration project in Lahti in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Palonen, J [Foster Wheeler Energia Oy, Varkaus (Finland). Varkaus Global New Products

    1998-12-31

    The successful experience in developing the advanced Foster Wheeler Energi Oy`s (former Ahlstroem Pyropower) Circulating Fluidized Bed combustion system subsequently led to the development of the CFB gasification technology in the early 1980s. The driving force for the developing work was the dramatic increase in oil price during the oil crises. The primary advantage of CFB gasification technology is that the it enables the substitution of expensive fuels e.g. oil or gas with cheap solid fuels. These cheap fuels are typically different types of waste woods, bark or other biofuels. In the CFB gasifier these solid fuels are converted to gaseous fuel which can be used instead of other expensive fuels. In some cases this also solves a waste disposal problem, providing a secondary economic and environmental benefit. Foster Wheeler Energia Oy has supplied four commercial scale atmospheric CFB gasifiers in the mid 80s to the pulp and paper industry with capacities from 17 to 35 MW based on fuel input. These applications utilize waste wood as feedstock and the units are still successfully operation today. Lahden Laempoevoima Oy is a Finnish power company producing power and district heat for the city of Lahti. The company is 50 % owned by the city of Lahti and 50 % by Imatran Voima Oy, which is the largest utility power company in Finland. Lahden Laempoevoima Oy operates the Kymijaervi power plant locating nearby the city of Lahti in Southern Finland. To keep the energy prices as low as possible, Lahden Laempoevoima is continuously looking for the most economical fuel sources, and simultaneously, trying to improve the environmental acceptability of the energy production. At the moment, about 300 GWh/a different type of biofuels and refuse fuels are available in the Lahti area. On an annual basis, the available amount of biofuels and refuse fuels is enough to substitute for about 15 % of the fuels burned in the main boiler equalling max 30 % of coal. The aim in this Lahden

  18. Continental-scale simulation of burn probabilities, flame lengths, and fire size distribution for the United States

    Science.gov (United States)

    Mark A. Finney; Charles W. McHugh; Isaac Grenfell; Karin L. Riley

    2010-01-01

    Components of a quantitative risk assessment were produced by simulation of burn probabilities and fire behavior variation for 134 fire planning units (FPUs) across the continental U.S. The system uses fire growth simulation of ignitions modeled from relationships between large fire occurrence and the fire danger index Energy Release Component (ERC). Simulations of 10,...

  19. Adsorption of phenolic compound by aged-refuse

    Energy Technology Data Exchange (ETDEWEB)

    Chai Xiaoli [State Key Laboratory of Pollution Control and Resource Reuse, School of Enviromental Science and Engineering, Tongji University, Siping Road 1239, Shanghai 200092 (China)]. E-mail: xlchai@mail.tongji.edu.cn; Zhao Youcai [State Key Laboratory of Pollution Control and Resource Reuse, School of Enviromental Science and Engineering, Tongji University, Siping Road 1239, Shanghai 200092 (China)

    2006-09-01

    The adsorption of phenol, 2-chlorophenol, 4-chlorophenol and 2,4-dichlorophenol by aged-refuse has been studied. Adsorption isotherms have been determined for phenol, 2-chlorophenol, 4-chlorophenol and 2,4-dichlorophenol and the data fits well to the Freundlich equation. The chlorinated phenols are absorbed more strongly than the phenol and the adsorption capacity has an oblivious relationship with the numbers and the position of chlorine subsistent. The experiment data suggests that both the partition function and the chemical adsorption involve in the adsorption process. Pseudo-first-order and pseudo-second-order model were applied to investigate the kinetics of the adsorption and the results show that it fit the pseudo-second-order model. More than one step involves in the adsorption process and the overall rate of the adsorption process appears to be controlled by the chemical reaction. The thermodynamic analysis indicates that the adsorption is spontaneous and endothermic.

  20. Transfusion Refusal and the Shifting Limits of Multicultural Accommodation.

    Science.gov (United States)

    DeMichelis, Carey

    2017-12-01

    The refusal of blood products by Jehovah's Witness patients has provoked court proceedings, social science research, and contemporary fiction, all of which emphasize a seemingly intractable conflict between religious and secular ways of being. This article takes a different approach, focusing instead on the space that Witness patients have carved out for their accommodation in a major pediatric research hospital. Using discourse analysis and interview data, I map the way moralizing discourses surrounding Witness families have shifted over the past 70 years alongside advancements in bloodless medicine. I argue that Witnesses have helped to enable their present accommodation and recognition by marshaling particular forms of economic, human, and social capital, and consider whether their success might be attainable by other treatment-resisting patient groups. Thus, this article explores the shifting limits of multicultural accommodation and the conditions that make understanding, collaboration, and compromise possible.

  1. A case of pervasive refusal syndrome: a diagnostic conundrum.

    LENUS (Irish Health Repository)

    McNicholas, Fiona

    2013-01-01

    A case is presented of an 11-year-old girl with pervasive refusal syndrome (PRS) who ultimately recovered acutely and completely after an 18-month paediatric hospitalisation. There was an apparent absence of previously proposed important aetiological factors in PRS, such as family pathology and markedly traumatic or abusive experiences, and her recovery was sudden and complete. The authors consider the differential diagnoses of PRS paying particular attention to the possibility of a conversion disorder or catatonia, given the absence of PRS in the North American literature. Consideration of catatonia is important as it has a diagnostic test and responds rapidly to appropriate treatment, in contrast to conventional treatment for PRS and conversion disorder.

  2. Renouncement of renal replacement therapy: withdrawal and refusal

    Directory of Open Access Journals (Sweden)

    José Andrade Moura Neto

    Full Text Available Abstract Renouncement of renal replacement therapy (RRT is a medical dilemma. This review covers the concept, the magnitude, the prognosis, and discusses strategies and management approaches about this subject in patients with CKD and AKI. Evidence suggests that refusal is more frequent and carries a more guarded prognosis than withdrawal of RRT. When RRT is not expected to be beneficial in terms of survival or quality of life, conservative treatment and palliative care are alternatives. We review the historical evolution of guidelines about renouncement of RRT and palliative care, and highlight the absence of specific recommendations in Brazil. However renouncement of RRT may be ethically and legally accepted in Brazil, as the right to a dignified death. Longer life expectancy, economic pressures, and greater awareness will require a more detailed discussion about indications and sustainable use of RRT, and possibly the elaboration of national guidelines.

  3. Social and legal dimensions discussion of conscientious refusal in Turkey

    Directory of Open Access Journals (Sweden)

    Şeniz ANBARLI BOZATAY

    2011-12-01

    Full Text Available Even though the discussion of conscientious objection, the refusal of military service due to individual’s moral values or religious beliefs, is new in Turkey, the subject has become the focus of intense interest. The discussion of conscientious objection in Turkey has come the to the fore with the heated debates between the glorification of the dynamics of Turkish social structure towards military service and the critique of militarism and conscientious objection’s legal dimensions, as well. Since the reduction of discussions in this context in Turkey to the legal dimension is the ignorance of social reality constituting basis to the legal dimension, the subject is examined with reference to the social and historical outlook on this issue and the study is built on dimensions.

  4. Treatment guidelines for primary nonretentive encopresis and stool toileting refusal.

    Science.gov (United States)

    Kuhn, B R; Marcus, B A; Pitner, S L

    1999-04-15

    Nonretentive encopresis refers to inappropriate soiling without evidence of fecal constipation and retention. This form of encopresis accounts for up to 20 percent of all cases. Characteristics include soiling accompanied by daily bowel movements that are normal in size and consistency. An organic cause for nonretentive encopresis is rarely identified. The medical assessment is usually normal, and signs of constipation are noticeably absent. A full developmental and behavioral assessment should be made to establish that the child is ready for intervention to correct encopresis and to identify any barriers to success, particularly disruptive behavior problems. Successful interventions depend on the presence of soft, comfortable bowel movements and addressing toilet refusal behavior. Daily scheduled positive toilet sits are recommended. Incentives may be used to reinforce successful defecation during these sits. A plan for management of stool withholding should be agreed on by the parents/caretakers and the family physician before intervention.

  5. Adsorption of phenolic compound by aged-refuse

    International Nuclear Information System (INIS)

    Chai Xiaoli; Zhao Youcai

    2006-01-01

    The adsorption of phenol, 2-chlorophenol, 4-chlorophenol and 2,4-dichlorophenol by aged-refuse has been studied. Adsorption isotherms have been determined for phenol, 2-chlorophenol, 4-chlorophenol and 2,4-dichlorophenol and the data fits well to the Freundlich equation. The chlorinated phenols are absorbed more strongly than the phenol and the adsorption capacity has an oblivious relationship with the numbers and the position of chlorine subsistent. The experiment data suggests that both the partition function and the chemical adsorption involve in the adsorption process. Pseudo-first-order and pseudo-second-order model were applied to investigate the kinetics of the adsorption and the results show that it fit the pseudo-second-order model. More than one step involves in the adsorption process and the overall rate of the adsorption process appears to be controlled by the chemical reaction. The thermodynamic analysis indicates that the adsorption is spontaneous and endothermic

  6. Treatment for School Refusal among Children and Adolescents: A Systematic Review and Meta-Analysis

    Science.gov (United States)

    Maynard, Brandy R.; Heyne, David; Brendel, Kristen Esposito; Bulanda, Jeffery J.; Thompson, Aaron M.; Pigott, Terri D.

    2018-01-01

    Objective: School refusal is a psychosocial problem associated with adverse short- and long-term consequences for children and adolescents. The authors conducted a systematic review and meta-analysis to examine the effects of psychosocial treatments for children and adolescents with school refusal. Method: A comprehensive search process was used…

  7. 49 CFR 655.49 - Refusal to submit to a drug or alcohol test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Refusal to submit to a drug or alcohol test. 655... TRANSIT ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PREVENTION OF ALCOHOL MISUSE AND PROHIBITED DRUG USE IN TRANSIT OPERATIONS Types of Testing § 655.49 Refusal to submit to a drug or alcohol test. (a) Each...

  8. 24 CFR 3282.354 - Submittal of false information or refusal to submit information.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Submittal of false information or... ENFORCEMENT REGULATIONS Primary Inspection Agencies § 3282.354 Submittal of false information or refusal to submit information. The submittal of false information or the refusal to submit information required...

  9. Making Sense of Iconic Symbols: A Study of Preschool Children Conducting a Refuse-Sorting Task

    Science.gov (United States)

    Ljung-Djärf, Agneta; Åberg-Bengtsson, Lisbeth; Ottosson, Torgny; Beach, Dennis

    2015-01-01

    This article is part of a larger project focusing upon explanatory illustrations that children encounter in pre- and primary school education. The research questions concerned (a) how preschool children make sense of iconic symbols when placing items of refuse on illustrations of refuse bins in a sorting task and (b) what stumbling blocks they…

  10. Bacteria and Acidic Drainage from Coal Refuse: Inhibition by Sodium Lauryl Sulfate and Sodium Benzoate

    OpenAIRE

    Dugan, Patrick R.; Apel, William A.

    1983-01-01

    The application of an aqueous solution of sodium lauryl sulfate and sodium benzoate to the surface of high-sulfur coal refuse resulted in the inhibition of iron-and sulfur-oxidizing chemoautotrophic bacteria and in the decrease of acidic drainage from the refuse, suggesting that acid drainage can be abated in the field by inhibiting iron- and sulfur-oxidizing bacteria.

  11. Thinking through Moments of Sexual Refusal in "Looking for Alibrandi" and "The Rage in Placid Lake"

    Science.gov (United States)

    Clarke, Kyra

    2016-01-01

    This paper explores two scenarios in which young women refuse the sexual advances of young men in the films "Looking for Alibrandi" and "The Rage in Placid Lake." The paper highlights the heteronormative nature of education around refusing sex, which reinstates gendered stereotypes of masculine as active and feminine as…

  12. Learned Helplessness and Learning Goals: Role played in School Refusal. A Study on Italian Students.

    Directory of Open Access Journals (Sweden)

    Luana Sorrenti

    2016-08-01

    Full Text Available Literature on school refusal has shown a link between school refusal and poor school performance. However, there has been little investigation into the individual underlying factors, and specifically factors directly related to the learning process, such as the learning goals of students and their expectations of success and/or failure. The main purpose of the present study is to investigate the influence of Learned Helplessness (LH and learning goals on school refusal. We hypothesized that LH and learning goals exert a unique role in predicting school refusal above and beyond the roles of academic achievement, age, and gender. The sample consisted of 201 Italian students with an average age of 11.93, with both low (57.2 % of students and high (42.8 % academic achievement. School refusal, LH, and learning goals were measured by means of questionnaires. The results confirm the hypothesis of this study; in fact, we found that learning goals and, above all, LH play a more predictive role of school refusal than academic achievement. These results extend previous studies on school refusal and, for the first time, they provide additional knowledge about this problem, analyzing the relationship between school refusal, learning goals, and LH, still neglected in the literature. Implications on the psychological well-being of students are discussed.

  13. The Impact of Refuse Dump sites on the Physico-chemical and ...

    African Journals Online (AJOL)

    The Impact of Refuse Dump sites on the Physico-chemical and Microbial Properties of ground Water in some selected areas. ... Journal of Agricultural Research and Development. Journal Home ... The pollution effect of refuse dumps on the quality of wells at Ojota, Lagos, Apete, Ibadan and Odopetu, Akure were studied.

  14. What happens after a request for euthanasia is refused? Qualitative interviews with patients, relatives and physicians.

    Science.gov (United States)

    Pasman, H Roeline W; Willems, Dick L; Onwuteaka-Philipsen, Bregje D

    2013-09-01

    Obtaining in-depth information from both patient and physician perspectives about what happens after a request for euthanasia or physician-assisted suicide (EAS) is refused. In-depth interviews with nine patients whose EAS request was refused and seven physicians of these patients, and with three relatives of patients who had died after a request was refused and four physicians of these patients. Interviews were conducted at least 6 months after the refusal. A wish to die remained in all patients after refusal, although it sometimes diminished. In most cases patient and physician stopped discussing this wish, and none of the physicians had discussed plans for the future with the patient or evaluated the patient's situation after their refusal. Physicians were aware of patients' continued wish to die. Patients who are refused EAS may subsequently be silent about a wish to die without abandoning it. Open communication about wishes to die is important, even outside the context of EAS, because if people feel unable to talk about them, their quality of life may be further diminished. Follow up appointments after refusal could give patients the opportunity to discuss their feelings and physicians to support them. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Can children aged 12 years or more refuse life-saving treatment ...

    African Journals Online (AJOL)

    The best interests of the child are paramount, and should the child unreasonably refuse to consent to life-saving treatment, the Minister of Social Development may give consent for such treatment in terms of the Children's Act. Otherwise, should a parent, guardian, caregiver or healthcare provider believe that such a refusal ...

  16. Behavioural treatment of severe food refusal in five toddlers with developmental disabilities

    NARCIS (Netherlands)

    Moor, J.M.H. de; Didden, H.C.M.; Korzilius, H.P.L.M.

    2007-01-01

    BACKGROUND: Young children with developmental disabilities are at risk of food refusal. In case of severe food refusal, children are being fed by nasal or gastrostomy tube. Behavioural treatment may be effective in establishing oral food intake. METHODS: A behavioural treatment package was

  17. Behavioral treatment of severe food refusal in five toddlers with developmental disabilities

    NARCIS (Netherlands)

    Moor, J.M.H. de; Didden, H.C.M.; Korzilius, H.P.L.M.

    2007-01-01

    Background Young children with developmental disabilities are at risk of food refusal. In case of severe food refusal, children are being fed by nasal or gastrostomy tube. Behavioural treatment may be effective in establishing oral food intake. Methods A behavioural treatment package was

  18. Behavioural treatment of severe food refusal in five toddlers with developmental disabilities.

    NARCIS (Netherlands)

    Moor, J.M.H. de; Didden, R.; Korzilius, H.P.L.M.

    2007-01-01

    BACKGROUND: Young children with developmental disabilities are at risk of food refusal. In case of severe food refusal, children are being fed by nasal or gastrostomy tube. Behavioural treatment may be effective in establishing oral food intake. METHODS: A behavioural treatment package was

  19. What happens after a request for euthanasia is refused? Qualitative interviews with patients, relatives and physicians

    NARCIS (Netherlands)

    Pasman, H.R.W.; Willems, D.L.; Onwuteaka-Philipsen, B.D.

    2013-01-01

    Objective: Obtaining in-depth information from both patient and physician perspectives about what happens after a request for euthanasia or physician-assisted suicide (EAS) is refused. Methods: In-depth interviews with nine patients whose EAS request was refused and seven physicians of these

  20. Comparing the quality of life in insulin recipient and refusal patients with type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Mitra Khalili

    2016-01-01

    Conclusions: Results showed that insulin refusal patients had a better QOL. It seems that QOL is associated with the acceptance or refusal of insulin therapy. Therefore, enhancement of QOL could be related to all aspects of the disease, especially its treatment method and solving the therapeutic problems.

  1. Using Descriptive Assessment in the Treatment of Bite Acceptance and Food Refusal

    Science.gov (United States)

    Casey, Sean D.; Perrin, Christopher J.; Lesser, Aaron D.; Perrin, Stefanie H.; Casey, Cheryl L.; Reed, Gregory K.

    2009-01-01

    The feeding behaviors of two children who maintained failure to thrive diagnoses and displayed food refusal are assessed in their homes. Descriptive assessments are used to identify schedules of consequence provided by each child's care providers for bite acceptance and food refusal behaviors. Assessments reveal rich schedules of praise and access…

  2. A plea for uniform European definitions for organ donor potential and family refusal rates.

    Science.gov (United States)

    Jansen, Nichon E; Haase-Kromwijk, Bernadette J J M; van Leiden, Hendrik A; Weimar, Willem; Hoitsma, Andries J

    2009-11-01

    Conversion of potential organ donors to actual donors is negatively influenced by family refusals. Refusal rates differ strongly among countries. Is it possible to compare refusal rates in order to be able to learn from countries with the best practices? We searched in the literature for reviews of donor potential and refusal rates for organ donation in intensive care units. We found 14 articles pertinent to this study. There is an enormous diversity among the performed studies. The definitions of potential organ donors and family refusal differed substantially. We tried to re-calculate the refusal rates. This method failed because of the influence caused by the registered will on donation in the Donor Register. We therefore calculated the total refusal rate. This strategy was also less satisfactory considering possible influence of the legal consent system on the approach of family. Because of lack of uniform definitions, we can conclude that the refusal rates for organ donation can not be used for a sound comparison among countries. To be able to learn from well-performing countries, it is necessary to establish uniform definitions regarding organ donation and registration of all intensive care deaths.

  3. Obstetric Patients Who Select and Those Who Refuse Medical Students' Participation in Their Care.

    Science.gov (United States)

    Magrane, Diane; And Others

    1994-01-01

    A survey of 222 obstetrics patients assisted by medical clerkship students from the University of Vermont and 78 who refused student participation found privacy the primary motivation for refusal and a desire to contribute to students' education a primary reason for accepting student participation. Patients frequently erroneously anticipated the…

  4. 21 CFR 515.21 - Refusal to approve a medicated feed mill license application.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Refusal to approve a medicated feed mill license... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS MEDICATED FEED MILL LICENSE Administrative Actions on Licenses § 515.21 Refusal to approve a medicated feed mill license application. (a) The...

  5. Strategie di rifuto in Italiano: uno studio etnografico (Refusal Strategies in Italian: An Ethnographic Study).

    Science.gov (United States)

    Frescura, Marina

    1997-01-01

    After reviewing previous research on speech acts, this article describes a study that analyzed the behavior of speakers of standard Italian in refusing an offer of food. The importance of "face" is explained, and the refusal strategies are classified into four categories: explicit, tactical, decisive, and conclusive. (CFM)

  6. 13 CFR 115.18 - Refusal to issue further guarantees; suspension and termination of PSB status.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Refusal to issue further guarantees; suspension and termination of PSB status. 115.18 Section 115.18 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION SURETY BOND GUARANTEE Provisions for All Surety Bond Guarantees § 115.18 Refusal to issue further guarantees; suspension...

  7. 75 FR 4565 - Federal Acquisition Regulation; Submission for OMB Review; Right of First Refusal of Employment

    Science.gov (United States)

    2010-01-28

    .... Please cite OMB Control No. 9000-0114, Right of First Refusal of Employment, in all correspondence. Dated... ADMINISTRATION [OMB Control No. 9000-0114] Federal Acquisition Regulation; Submission for OMB Review; Right of... previously approved information collection requirement concerning right of first refusal of employment. A...

  8. 29 CFR 1977.22 - Employee refusal to comply with safety rules.

    Science.gov (United States)

    2010-07-01

    ... WILLIAMS-STEIGER OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 Some Specific Subjects § 1977.22 Employee refusal to comply with safety rules. Employees who refuse to comply with occupational safety and health... Section 1977.22 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH...

  9. 30 CFR 253.50 - How can MMS refuse or invalidate my OSFR evidence?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How can MMS refuse or invalidate my OSFR... can MMS refuse or invalidate my OSFR evidence? (a) If MMS determines that any OSFR evidence you submit... acceptable evidence without being subject to civil penalty under § 253.51. (b) MMS may immediately and...

  10. Denitrification capacity of bioreactors filled with refuse at different landfill ages

    International Nuclear Information System (INIS)

    Chen Yingxu; Wu Songwei; Wu Weixiang; Sun Hua; Ding Ying

    2009-01-01

    The denitrification capacity of refuse at different landfill ages in bioreactor landfill system was studied. Three reactors filled with 1-year-old refuse (R1), 6-year-old refuse (R6) and 11-year-old refuse (R11), respectively, were operated in the experiment. Nitrate solution (1000 mg NO 3 - -N L -1 ) was added into each reactor. The results showed that the reactors were all able to consume nitrate. However, 1-year-old refuse in R1 had both a higher nitrate reduction rate and concentration of N 2 . In addition, vertical differences in nitrate removal along the depth of R1 were observed. The bottom-layer refuse and the middle-layer refuse both showed higher efficiency in nitrate depletion than the top layer. Furthermore, N 2 O accumulation was found in R11 with the concentration up to 19.3% of the released gas. These results suggested that 1-year-old refuse, which was partly degraded, was more suitable to use as denitrification medium.

  11. Fires, ecological effects of

    Science.gov (United States)

    W. J. Bond; Robert Keane

    2017-01-01

    Fire is both a natural and anthropogenic disturbance influencing the distribution, structure, and functioning of terrestrial ecosystems around the world. Many plants and animals depend on fire for their continued existence. Others species, such as rainforest plants species, are extremely intolerant of burning and need protection from fire. The properties of a fire...

  12. Patient Experience Of Provider Refusal Of Medicaid Coverage And Its Implications.

    Science.gov (United States)

    Bhandari, Neeraj; Shi, Yunfeng; Jung, Kyoungrae

    2016-01-01

    Previous studies show that many physicians do not accept new patients with Medicaid coverage, but no study has examined Medicaid enrollees' actual experience of provider refusal of their coverage and its implications. Using the 2012 National Health Interview Survey, we estimate provider refusal of health insurance coverage reported by 23,992 adults with continuous coverage for the past 12 months. We find that among Medicaid enrollees, 6.73% reported their coverage being refused by a provider in 2012, a rate higher than that in Medicare and private insurance by 4.07 (p<.01) and 3.68 (p<.001) percentage points, respectively. Refusal of Medicaid coverage is associated with delaying needed care, using emergency room (ER) as a usual source of care, and perceiving current coverage as worse than last year. In view of the Affordable Care Act's (ACA) Medicaid expansion, future studies should continue monitoring enrollees' experience of coverage refusal.

  13. Building 431 fire tests

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Ford, H.W.; Magee, M.W.

    1977-01-01

    An extensive discussion of considerations for fire protection in the LLL mirror fusion test facility (MFTF) is presented. Because of the large volume and high bays of the building, sufficient data on fire detection is unavailable. Results of fire detection tests using controlled fire sources in the building are presented. Extensive data concerning the behavior of the building atmosphere are included. Candidate fire detection instrumentation and extinguishing systems for use in the building are briefly reviewed

  14. Fire-Walking

    Science.gov (United States)

    Willey, David

    2010-01-01

    This article gives a brief history of fire-walking and then deals with the physics behind fire-walking. The author has performed approximately 50 fire-walks, took the data for the world's hottest fire-walk and was, at one time, a world record holder for the longest fire-walk (www.dwilley.com/HDATLTW/Record_Making_Firewalks.html). He currently…

  15. Fire, safety and ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, D.

    1999-02-01

    Correct ventilation in tunnel environments is vital for the comfort and safety of the people passing through. This article gives details of products from several manufacturers of safety rescue and fire fighting equipment, fire and fume detection equipment, special fire resistant materials, fire resistant hydraulic oils and fire dampers, and ventilation systems. Company addresses and fax numbers are supplied. 4 refs., 5 tabs., 10 photos.

  16. Refusal of curative radiation therapy and surgery among patients with cancer.

    Science.gov (United States)

    Aizer, Ayal A; Chen, Ming-Hui; Parekh, Arti; Choueiri, Toni K; Hoffman, Karen E; Kim, Simon P; Martin, Neil E; Hu, Jim C; Trinh, Quoc-Dien; Nguyen, Paul L

    2014-07-15

    Surgery and radiation therapy represent the only curative options for many patients with solid malignancies. However, despite the recommendations of their physicians, some patients refuse these therapies. This study characterized factors associated with refusal of surgical or radiation therapy as well as the impact of refusal of recommended therapy on patients with localized malignancies. We used the Surveillance, Epidemiology, and End Results program to identify a population-based sample of 925,127 patients who had diagnoses of 1 of 8 common malignancies for which surgery and/or radiation are believed to confer a survival benefit between 1995 and 2008. Refusal of oncologic therapy, as documented in the SEER database, was the primary outcome measure. Multivariable logistic regression was used to investigate factors associated with refusal. The impact of refusal of therapy on cancer-specific mortality was assessed with Fine and Gray's competing risks regression. In total, 2441 of 692,938 patients (0.4%) refused surgery, and 2113 of 232,189 patients (0.9%) refused radiation, despite the recommendations of their physicians. On multivariable analysis, advancing age, decreasing annual income, nonwhite race, and unmarried status were associated with refusal of surgery, whereas advancing age, decreasing annual income, Asian American race, and unmarried status were associated with refusal of radiation (PRefusal of surgery and radiation were associated with increased estimates of cancer-specific mortality for all malignancies evaluated (hazard ratio [HR], 2.80, 95% confidence interval [CI], 2.59-3.03; Prefuse curative surgical and/or radiation-based oncologic therapy, raising concern that socioeconomic factors may drive some patients to forego potentially life-saving care. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Learning fire-fighting lessons after Chernobyl

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Fire protection measures in Soviet nuclear power plants were set out in November 1987, in the Nuclear Power Plant Design Fire Protection Standards (VSN 01-87, USSR Ministry of Atomic Energy). The most important of these measures are. Avoiding as far as possible the use of combustible materials in plant structures and equipment. Dividing buildings and areas into suitable fire-fighting zones. Ensuring reliable fire protection of the control and safety systems. Protecting technical personnel from the dangers of a fire while they are performing essential accident-repair work and facilitating evacuation procedures (providing at least two evacuation routes and exits, anti-smoke protection of evacuation routes and control panel areas etc). Installing automatic fire-extinguishing and fire alarm systems. Providing various stationary facilities and equipment to assist the use of mobile fire-fighting appliances. In addition, a special fire-fighting division is being set up in every nuclear power plant while the first unit is still being constructed. These divisions work in close co-operation with the technical personnel management of the plant and with the bodies responsible for monitoring nuclear safety. (author)

  18. FIRES: Fire Information Retrieval and Evaluation System - A program for fire danger rating analysis

    Science.gov (United States)

    Patricia L. Andrews; Larry S. Bradshaw

    1997-01-01

    A computer program, FIRES: Fire Information Retrieval and Evaluation System, provides methods for evaluating the performance of fire danger rating indexes. The relationship between fire danger indexes and historical fire occurrence and size is examined through logistic regression and percentiles. Historical seasonal trends of fire danger and fire occurrence can be...

  19. The Refusal of Palliative Radiation in Metastatic Non-Small Cell Lung Cancer and Its Prognostic Implications.

    Science.gov (United States)

    Stavas, Mark J; Arneson, Kyle O; Ning, Matthew S; Attia, Albert A; Phillips, Sharon E; Perkins, Stephanie M; Shinohara, Eric T

    2015-06-01

    Patients with metastatic non-small cell lung cancer (NSCLC) have limited survival. Population studies have evaluated the impact of radiation refusal in the curative setting; however, no data exist concerning the prognostic impact of radiation refusal in the palliative care setting. To investigate the patterns of radiation refusal in newly diagnosed patients with metastatic NSCLC. Patients with Stage IV NSCLC diagnosed between 1988 and 2010 were identified in the Surveillance, Epidemiology, and End Results database. Univariate and multivariate analyses were used to identify predictors for refusal of radiation and the impact of radiation and refusal on survival in the palliative setting. A total of 285,641 patients were initially included in the analysis. Palliative radiation was recommended in 42% and refused by 3.1% of patients. Refusal rates remained consistent across included years of study. On multivariate analysis, older, nonblack/nonwhite, unmarried females were more likely to refuse radiation (P refusing radiation was three months vs. five months for those receiving radiation and two months for those whom radiation was not recommended. Patients with metastatic NSCLC who refuse recommended palliative radiation have a poor survival. Radiation refusal or the recommendation against treatment can serve as a trigger for integrating palliative care services sooner and contributes greatly to prognostic awareness. Further investigation into this survival difference and the factors behind refusal are warranted. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  20. 25 CFR 171.420 - Can I dispose of sewage, trash, or other refuse on a BIA irrigation project?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Can I dispose of sewage, trash, or other refuse on a BIA... AND WATER IRRIGATION OPERATION AND MAINTENANCE Irrigation Facilities § 171.420 Can I dispose of sewage, trash, or other refuse on a BIA irrigation project? No. Sewage, trash, or other refuse are considered...

  1. In-depth investigation of high-energy arcing faults (HEAF) of electrical components with possible induced fires; Vertiefte Untersuchungen zum hochenergetischen Versagen elektrischer Komponenten (HEAF) mit moeglicher Brandfolge

    Energy Technology Data Exchange (ETDEWEB)

    Roewekamp, Marina

    2015-11-15

    Main objective of the project 3611R01301 performed on behalf of the Federal Ministry for the Environment, Nature Conservation, Building and Nuclear Safety (BMUB) is an in-depth investigation of fires at electrical components induced by high energy arcing faults (HEAF) according to their non-negligible significance to nuclear safety. This report provides an overview on the insights with respect to high energy arcing faults at electrical components mainly gained from investigations of the national as well as international operating experience from nuclear installations. Moreover, the insights from the international operating experience have resulted in an experimental program carried out in the frame of a task by the OECD Nuclear Energy Agency (NEA) in order to investigate failures of electrical components, e. g. breakers, switchgears or transformers, installed in nuclear power plants of the member countries due to HEAF and potential consequential fires. The results of the in-depth analyses and experimental investigations shall be used for identifying potential areas of damage in a suitable manner. The results based on inter-national research shall also be checked with respect to their applicability to the situation in German nuclear power plants.

  2. Corrosion and Materials Performance in biomass fired and co-fired power plants

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Larsen, OH; Biede, O

    2003-01-01

    not previously encountered in coal-fired power plants. The type of corrosion attack can be directly ascribed to the composition of the deposit and the metal surface temperature. In woodchip boilers, a similar corrosion rate and corrosion mechanism has on some occasions been observed. Co-firing of straw (10...... and 20% energy basis) with coal has shown corrosion rates lower than those in straw-fired plants. With both 10 and 20% straw, no chlorine corrosion was seen. This paper will describe the results from in situ investigations undertaken in Denmark on high temperature corrosion in biomass fired plants....... Results from 100% straw-firing, woodchip and co-firing of straw with coal will be reported. The corrosion mechanisms observed are summarized and the corrosion rates for 18-8 type stainless steels are compared....

  3. Heroin refusal self-efficacy and preference for medication-assisted treatment after inpatient detoxification.

    Science.gov (United States)

    Kenney, Shannon R; Bailey, Genie L; Anderson, Bradley J; Stein, Michael D

    2017-10-01

    An individual's self-efficacy to refuse using heroin in high-risk situations is believed to minimize the likelihood for relapse. However, among individuals completing inpatient heroin detoxification, perceived refusal self-efficacy may also reduce one's perceived need for medication-assisted treatment (MAT), an effective and recommended treatment for opioid use disorder. In the current study, we examined the relationship between heroin refusal self-efficacy and preference for MAT following inpatient detoxification. Participants (N=397) were interviewed at the start of brief inpatient opioid detoxification. Multiple logistic regression was used to estimate the adjusted association of background characteristics, depressed mood, and perceived heroin refusal self-efficacy with preference for MAT. Controlling for other covariates, depressed mood and lower perceived refusal self-efficacy were associated with a significantly greater likelihood of expressing preference for MAT (versus no MAT). Perceived ability to refuse heroin after leaving detox is inversely associated with a heroin user's desire for MAT. An effective continuum of care model may benefit from greater attention to patient's perceived refusal self-efficacy during detoxification which may impact preference for MAT and long-term recovery. Copyright © 2017. Published by Elsevier Ltd.

  4. The right to physical integrity and informed refusal: Just how far does a patient’s right to refuse medical treatment go?

    Directory of Open Access Journals (Sweden)

    Annelize Nienaber

    2016-11-01

    Full Text Available The article presents a legal analysis of the right to physical integrity as guaranteed by the South African Constitution, 1996, and the subsequent right of a competent adult person to refuse medical treatment under South African law. We consider whether the right to refuse treatment is an absolute right and very briefly reflect on the application of the constitutional limitations clause to this right. Instances in which patients’ right to physical integrity is limited by factors, which detract from (patient autonomy, are considered: these represent a limitation of their right to refuse medical treatment. We conclude that forced medical interventions, for the most part, are not desirable but, indeed, necessary in some narrowly defined circumstances. When a person makes a decision to refuse a medical intervention, which may seem unusual or may be perceived as irrational, it does not mean that person does not warrant the protection of the constitution and the courts. Provided that the patient makes an informed refusal while of sound mind, generally there is no reason to discredit his/her decision, difficult as it may be for others to accept. At all times the right to bodily integrity is pivotal in any health-related context and should not be lightly disregarded.

  5. Fire risk assessment for hydrogen at EDG/battery room

    Energy Technology Data Exchange (ETDEWEB)

    Jee, Moon Hak; Hong, Sung Yull; Choi, Kwang Hee; Jung, Hyun Jong; Park, Kyung Hyum [Korea electric Power Research Institute, Taejon (Korea, Republic of); Song, Jin Bae [KHNP, Wolsong (Korea, Republic of)

    2004-07-01

    At the design stage of Nuclear Power Plant, the fire hazard analysis for the fire zone or compartment is implemented according to the fire protection requirement and the document is required for the licensing approval. On the basis of fire hazard analysis, the evaluation for the safe shutdown capability is preceded for each fire zone that contains safety-important systems and facilities. The primary philosophy for the fire safety is to secure fire defense-in-depth at Nuclear Power Plants that represents fire prevention, fire protection, and mitigation from fire damage. One of the concerning fire zones that need quantitative fire hazard analysis as well as qualitative fire evaluation at Nuclear Power Plants is the battery room at Emergency Diesel Generator (EDG) Room. For an example, Emergency Power Supply System called as EPS at Wolsong Nuclear Power Plant generates emergency power and supply the electric power to the safety-related systems and essential facilities during the loss of on-site and off-site AC power. For the start of emergency power generator, it needs DC power from the battery units inside the EPS room. For the emergency supply of DC power, the battery at EPS room should be recharged during the standby period to compensate the reduced chemical energy that was converted to the electric energy or depleted through the natural process. During the recharge process, especially at the time of charging current becoming greater than the nominal floating current or at the time of over-charging period, the hydrogen and the oxygen are generated from the positive plate and cathodic part respectively and escaped through the vent holes or crevices. In this context, the fire hazard assessment should be done for the EPS/battery room with quantitative approach and the fire safety evaluation for the explosion of hydrogen gas must be done under the specific fire protection program at Nuclear Power Plants.

  6. Fire risk assessment for hydrogen at EDG/battery room

    International Nuclear Information System (INIS)

    Jee, Moon Hak; Hong, Sung Yull; Choi, Kwang Hee; Jung, Hyun Jong; Park, Kyung Hyum; Song, Jin Bae

    2004-01-01

    At the design stage of Nuclear Power Plant, the fire hazard analysis for the fire zone or compartment is implemented according to the fire protection requirement and the document is required for the licensing approval. On the basis of fire hazard analysis, the evaluation for the safe shutdown capability is preceded for each fire zone that contains safety-important systems and facilities. The primary philosophy for the fire safety is to secure fire defense-in-depth at Nuclear Power Plants that represents fire prevention, fire protection, and mitigation from fire damage. One of the concerning fire zones that need quantitative fire hazard analysis as well as qualitative fire evaluation at Nuclear Power Plants is the battery room at Emergency Diesel Generator (EDG) Room. For an example, Emergency Power Supply System called as EPS at Wolsong Nuclear Power Plant generates emergency power and supply the electric power to the safety-related systems and essential facilities during the loss of on-site and off-site AC power. For the start of emergency power generator, it needs DC power from the battery units inside the EPS room. For the emergency supply of DC power, the battery at EPS room should be recharged during the standby period to compensate the reduced chemical energy that was converted to the electric energy or depleted through the natural process. During the recharge process, especially at the time of charging current becoming greater than the nominal floating current or at the time of over-charging period, the hydrogen and the oxygen are generated from the positive plate and cathodic part respectively and escaped through the vent holes or crevices. In this context, the fire hazard assessment should be done for the EPS/battery room with quantitative approach and the fire safety evaluation for the explosion of hydrogen gas must be done under the specific fire protection program at Nuclear Power Plants

  7. Microbial ecology studies at two coal mine refuse sites in Illinois

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R. M.; Cameron, R. E.

    1978-01-01

    An investigation was made of the microflora associated with coal refuse at two abandoned mines in the midwestern United States. Information was gathered for both the edaphic and the biotic composition of the refuse material. Emphasis was placed on heterotrophic and autotrophic components as to numbers, kinds, and physiological groups. The presence of chemolithotrophs was also investigated. The relationship between abiotic and biotic components in regard to distribution of bacteria, fungi, and algae is discussed. Information presented in this report will be utilized in assessing trends and changes in microbial numbers and composition related to manipulations of the edaphic and biotic ecosystem components associated with reclamation of the refuse piles.

  8. [Refusal of care by a HIV-positive adolescent: role of the cross-cultural approach].

    Science.gov (United States)

    Bouaziz, Nora; Titia Rizzi, Alice

    The refusal of treatment is frequent in human immunodeficiency virus-positive adolescents. The clinical history of a teenage girl presenting severe immunodepression secondary to the virus, a depressive disorder and a refusal of treatment, illustrates the benefit of combined paediatric, child psychiatric and cross-cultural care as proposed by the Cochin-Paris Adolescent Centre. Working on the meaning of the refusal was a prerequisite for the construction of a care project forming part of a life project, as the psychopathological work could only begin once somatic care ensuring the patient's protection was in place. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. Turning refuse plastic into multi-walled carbon nanotube forest

    Science.gov (United States)

    Oh, Eugene; Lee, Jaegeun; Jung, Seung-Ho; Cho, Seungho; Kim, Hye-Jin; Lee, Sung-Hyun; Lee, Kun-Hong; Song, Kyong-Hwa; Choi, Chi-Hoon; Han, Do Suck

    2012-01-01

    A novel and effective method was devised for synthesizing a vertically aligned carbon nanotube (CNT) forest on a substrate using waste plastic obtained from commercially available water bottles. The advantages of the proposed method are the speed of processing and the use of waste as a raw material. A mechanism for the CNT growth was also proposed. The growth rate of the CNT forest was ∼2.5 μm min−1. Transmission electron microscopy images indicated that the outer diameters of the CNTs were 20–30 nm on average. The intensity ratio of the G and D Raman bands was 1.27 for the vertically aligned CNT forest. The Raman spectrum showed that the wall graphitization of the CNTs, synthesized via the proposed method was slightly higher than that of commercially available multi-walled carbon nanotubes (MWCNTs). We expect that the proposed method can be easily adapted to the disposal of other refuse materials and applied to MWCNT production industries. PMID:27877482

  10. Hygiene tests in the anaerobic digestion of household refuse

    Energy Technology Data Exchange (ETDEWEB)

    Maier, H.; Philipp, W.; Wekerle, J.; Strauch, D.

    In a pilot plant the disinfecting effect of composting the effluent of an anaerobic mesophilic digestion process of the organic fraction of household refuse was investigated. The dewatered effluent was mixed with straw as bulking material, put in not aerated windrows and aerobically composted. It was further investigated whether the influent of the digester could be disinfected with lime milk prior to the anaerobic mesophilic digestion process. For the evaluation of the disinfection salmonellas, enterococci, klebsiellas, parvo-, polio- and rotavirus were used as test agents. Temperature, total aerobic germ count, enterobacteriaceae and coliforms were also considered. The effect of lime milk in the influent on the digestion process, survival of the test bacteria and gas production was also studied. Both treatments can result in a hygienically safe product. But composting under the conditions given should not be operated during the winter period. Lime treatment of the influent results in a disinfection of the effluent which immediately can be utilized as liquid sludge in agriculture. (orig.)

  11. Turning refuse plastic into multi-walled carbon nanotube forest

    Directory of Open Access Journals (Sweden)

    Eugene Oh, Jaegeun Lee, Seung-Ho Jung, Seungho Cho, Hye-Jin Kim, Sung-Hyun Lee, Kun-Hong Lee, Kyong-Hwa Song, Chi-Hoon Choi and Do Suck Han

    2012-01-01

    Full Text Available A novel and effective method was devised for synthesizing a vertically aligned carbon nanotube (CNT forest on a substrate using waste plastic obtained from commercially available water bottles. The advantages of the proposed method are the speed of processing and the use of waste as a raw material. A mechanism for the CNT growth was also proposed. The growth rate of the CNT forest was ~2.5 μm min−1. Transmission electron microscopy images indicated that the outer diameters of the CNTs were 20–30 nm on average. The intensity ratio of the G and D Raman bands was 1.27 for the vertically aligned CNT forest. The Raman spectrum showed that the wall graphitization of the CNTs, synthesized via the proposed method was slightly higher than that of commercially available multi-walled carbon nanotubes (MWCNTs. We expect that the proposed method can be easily adapted to the disposal of other refuse materials and applied to MWCNT production industries.

  12. Negotiating refusal in primary care consultations: a qualitative study.

    Science.gov (United States)

    Walter, Alex; Chew-Graham, Carolyn; Harrison, Stephen

    2012-08-01

    How GPs negotiate patient requests is vital to their gatekeeper role but also a source of potential conflict, practitioner stress and patient dissatisfaction. Difficulties may arise when demands of shared decision-making conflict with resource allocation, which may be exacerbated by new commissioning arrangements, with GPs responsible for available services. To explore GPs' accounts of negotiating refusal of patient requests and their negotiation strategies. A qualitative design was employed with two focus groups of GPs and GP registrars followed by 20 semi-structured interviews. Participants were sampled by gender, experience, training/non-training, principal versus salaried or locum. Thematic content analysis proceeded in parallel with interviews and further sampling. The setting was GP practices within an English urban primary care trust. Sickness certification, antibiotics and benzodiazepines were cited most frequently as problematic patient requests. GP trainees reported more conflict within interactions than experienced GPs. Negotiation strategies, such as blaming distant third parties such as the primary care organization, were designed to prevent conflict and preserve the doctor-patient relationship. GPs reported patients' expectations being strongly influenced by previous encounters with other health care professionals. The findings reiterate the prominence of the doctor-patient relationship in GPs' accounts. GPs' relationships with colleagues and the wider National Health Service (NHS) are particular of relevance in light of provisions in the Health and Social Care Bill for clinical commissioning consortia. The ability of GPs to offset blame for rationing decisions to third parties will be undermined if the same GPs commission services.

  13. Wildland fire in ecosystems: effects of fire on flora

    Science.gov (United States)

    James K. Brown; Jane Kapler Smith

    2000-01-01

    VOLUME 2: This state-of-knowledge review about the effects of fire on flora and fuels can assist land managers with ecosystem and fire management planning and in their efforts to inform others about the ecological role of fire. Chapter topics include fire regime classification, autecological effects of fire, fire regime characteristics and postfire plant community...

  14. A review of fire interactions and mass fires

    Science.gov (United States)

    Mark A. Finney; Sara S. McAllister

    2011-01-01

    The character of a wildland fire can change dramatically in the presence of another nearby fire. Understanding and predicting the changes in behavior due to fire-fire interactions cannot only be life-saving to those on the ground, but also be used to better control a prescribed fire to meet objectives. In discontinuous fuel types, such interactions may elicit fire...

  15. Fires and Food Safety

    Science.gov (United States)

    ... Forms FSIS United States Department of Agriculture Food Safety and Inspection Service About FSIS District Offices Careers ... JSR 286) Actions ${title} Loading... Fires and Food Safety Fire! Few words can strike such terror. Residential ...

  16. Filosofiens historiografi: Fire genrer

    DEFF Research Database (Denmark)

    Rorty, Richard

    2007-01-01

    Oversættelse af Richard Rortys artikel "Filosofiens historiografi: Fire genrer" Udgivelsesdato: 26 Oktober......Oversættelse af Richard Rortys artikel "Filosofiens historiografi: Fire genrer" Udgivelsesdato: 26 Oktober...

  17. Tunnel fire dynamics

    CERN Document Server

    Ingason, Haukur; Lönnermark, Anders

    2015-01-01

    This book covers a wide range of issues in fire safety engineering in tunnels, describes the phenomena related to tunnel fire dynamics, presents state-of-the-art research, and gives detailed solutions to these major issues. Examples for calculations are provided. The aim is to significantly improve the understanding of fire safety engineering in tunnels. Chapters on fuel and ventilation control, combustion products, gas temperatures, heat fluxes, smoke stratification, visibility, tenability, design fire curves, heat release, fire suppression and detection, CFD modeling, and scaling techniques all equip readers to create their own fire safety plans for tunnels. This book should be purchased by any engineer or public official with responsibility for tunnels. It would also be of interest to many fire protection engineers as an application of evolving technical principles of fire safety.

  18. Fire Stations - 2007

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Station Locations in Kansas Any location where fire fighters are stationed at or based out of, or where equipment that such personnel use in carrying out their...

  19. Seerley Road Fire Site

    Science.gov (United States)

    A barn caught fire at on Seerley Road, Indianapolis. Five storage drums believed to contain metallic potassium were involved in the fire. EPA will perform additional sampling as part of removal operations and safe offsite transportation.

  20. Buildings exposed to fire

    International Nuclear Information System (INIS)

    1987-01-01

    The 24 lectures presented to the colloquium cover the following subject fields: (1) Behaviour of structural components exposed to fire; (2) Behaviour of building materials exposed to fire; (3) Thermal processes; (4) Safety related, theoretical studies. (PW) [de

  1. Interagency Wildland Fire Cooperation

    National Research Council Canada - National Science Library

    2004-01-01

    Wildlife Fire Assistance includes training personnel, forms partnerships for prescribed burns, state and regional data for fire management plans, develops agreements for DoD civilians to be reimbursed...

  2. Spacecraft Fire Safety Demonstration

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Spacecraft Fire Safety Demonstration project is to develop and conduct large-scale fire safety experiments on an International Space Station...

  3. Fire Stations - 2009

    Data.gov (United States)

    Kansas Data Access and Support Center — Fire Stations in Kansas Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their jobs is...

  4. FIRE CHARACTERISTICS FOR ADVANCED MODELLING OF FIRES

    Directory of Open Access Journals (Sweden)

    Otto Dvořák

    2016-07-01

    Full Text Available This paper summarizes the material and fire properties of solid flammable/combustible materials /substances /products, which are used as inputs for the computer numerical fire models. At the same time it gives the test standards for their determination.

  5. Loft fire protection

    International Nuclear Information System (INIS)

    White, E.R.; Jensen, J.D.

    1980-01-01

    Quantified criteria that was developed and applied to provide in-depth fire protection for the Loss of Fluid Test (LOFT) Facility are presented. The presentation describes the evolution process that elevated the facility's fire protection from minimal to that required for a highly protected risk or improved risk. Explored are some infrequently used fire protection measures that are poorly understood outside the fire protection profession

  6. A portable system for characterizing wildland fire behavior

    Science.gov (United States)

    Bret Butler; D. Jimenez; J. Forthofer; K. Shannon; Paul Sopko

    2010-01-01

    A field deployable system for quantifying energy and mass transport in wildland fires is described. The system consists of two enclosures: The first is a sensor/data logger combination package that allows characterization of convective/radiant energy transport in fires. This package contains batteries, a programmable data logger, sensors, and other electronics. The...

  7. Fire as Technology

    Science.gov (United States)

    Rudolph, Robert N.

    2011-01-01

    In this article, the author describes a project that deals with fire production as an aspect of technology. The project challenges students to be survivors in a five-day classroom activity. Students research various materials and methods to produce fire without the use of matches or other modern combustion devices, then must create "fire" to keep…

  8. Fourmile Canyon Fire Findings

    Science.gov (United States)

    Russell Graham; Mark Finney; Chuck McHugh; Jack Cohen; Dave Calkin; Rick Stratton; Larry Bradshaw; Ned Nikolov

    2012-01-01

    The Fourmile Canyon Fire burned in the fall of 2010 in the Rocky Mountain Front Range adjacent to Boulder, Colorado. The fire occurred in steep, rugged terrain, primarily on privately owned mixed ponderosa pine and Douglas-fir forests. The fire started on September 6 when the humidity of the air was very dry (¡Ö

  9. Autonomous Forest Fire Detection

    NARCIS (Netherlands)

    Breejen, E. den; Breuers, M.; Cremer, F.; Kemp, R.A.W.; Roos, M.; Schutte, K.; Vries, J.S. de

    1998-01-01

    Forest fire detection is a very important issue in the pre-suppression process. Timely detection allows the suppression units to reach the fire in its initial stages and this will reduce the suppression costs considerably. The autonomous forest fire detection principle is based on temporal contrast

  10. Fundamentals of Fire Phenomena

    DEFF Research Database (Denmark)

    Quintiere, James

    analyses. Fire phenomena encompass everything about the scientific principles behind fire behaviour. Combining the principles of chemistry, physics, heat and mass transfer, and fluid dynamics necessary to understand the fundamentals of fire phenomena, this book integrates the subject into a clear...

  11. Fire Department Emergency Response

    International Nuclear Information System (INIS)

    Blanchard, A.; Bell, K.; Kelly, J.; Hudson, J.

    1997-09-01

    In 1995 the SRS Fire Department published the initial Operations Basis Document (OBD). This document was one of the first of its kind in the DOE complex and was widely distributed and reviewed. This plan described a multi-mission Fire Department which provided fire, emergency medical, hazardous material spill, and technical rescue services

  12. Equipping tomorrow's fire manager

    Science.gov (United States)

    Christopher A. Dicus

    2008-01-01

    Fire managers are challenged with an ever-increasing array of both responsibilities and critics. As in the past, fire managers must master the elements of fire behavior and ecology using the latest technologies. In addition, today’s managers must be equipped with the skills necessary to understand and liaise with a burgeoning group of vocal stakeholders while also...

  13. Fire and forest meteorology

    Science.gov (United States)

    SA Ferguson; T.J. Brown; M. Flannigan

    2005-01-01

    The American Meteorological Society symposia series on Fire and Forest Meteorology provides biennial forums for atmospheric and fire scientists to introduce and discuss the latest and most relevant research on weather, climate and fire. This special issue highlights significant work that was presented at the Fifth Symposium in Orlando, Florida during 16-20 November...

  14. Cost of two fire

    International Nuclear Information System (INIS)

    Vasil'ev, Yu.

    2001-01-01

    The problem of the protection of nuclear sites in connection with the fires in summer of 2000 near two greatest nuclear sites: the Pacific Northwest National Laboratory located on the site of Hanford Nuclear Center, and Los Alamos National Laboratory is considered. Both fires occur beyond the Laboratories. Undertaken urgent procedures for fire fighting and recovery of the objects are characterized [ru

  15. How to justify enforcing a Ulysses contract when Ulysses is competent to refuse.

    Science.gov (United States)

    Davis, John K

    2008-03-01

    Sometimes the mentally ill have sufficient mental capacity to refuse treatment competently, and others have a moral duty to respect their refusal. However, those with episodic mental disorders may wish to precommit themselves to treatment, using Ulysses contracts known as "mental health advance directives." How can health care providers justify enforcing such contracts over an agent's current, competent refusal? I argue that providers respect an agent's autonomy not retrospectively--by reference to his or her past wishes-and not merely synchronically--so that the agent gets what he or she wants right now-but diachronically and prospectively, acting so that the agent can shape his or her circumstances as the agent wishes over time, for the agent will experience the consequences of providers' actions over time. Mental health directives accomplish this, so they are a way of respecting the agent's autonomy even when providers override the agent's current competent refusal.

  16. Biometric identification with high frequency electrocardiogram: Unregistered user refusal method and performance evaluation.

    Science.gov (United States)

    Kyoso, Masaki

    2015-08-01

    As a new modality for biometric identification, electrocardiogram-based identification technique has been developed. We proposed a technique with high frequency component of electrocardiogram (HFECG) in QRS segment. In this report, an unregistered user refusal algorithm was combined with the artificial neural network based waveform classifier. The refusal function was realized by simple thresholding technique. HFECGs from twenty collaborators were used for supervised learning. Twenty HFECGs from the same collaborators were tested and false acceptance rate (FAR) and false rejection rate (FRR) were evaluated. Ten HFECGs from other collaborators were also tested to find unregistered user refusal performance. The results show that FAR and FRR in the registrants can be kept within 1%, however, unregistered user refusal performance was not acceptable under the same condition.

  17. PATIENT’S CONSCIOUS REFUSAL OF TREATMENT AND REQUEST FOR ACTIVETREATMENT WHEN RECOVERY IS NOT POSSIBLE

    Directory of Open Access Journals (Sweden)

    Peter Černoga

    2008-01-01

    General practitioner and a specialist doctor are faced with difficult dilemma when there isa case of a competent but unwilling to consent patient refusing the timely treatment inspite of the predicted fatal consequences

  18. The right to physical integrity and informed refusal: Just how far does ...

    African Journals Online (AJOL)

    Provided that the patient makes an informed refusal while of sound mind, generally ... At all times the right to bodily integrity is pivotal in any health-related context and should ... choices regarding the body in an autonomous and independent.

  19. Right of a patient to refuse medical treatment: justification for judicial ...

    African Journals Online (AJOL)

    Nnamdi Azikiwe University Journal of International Law and Jurisprudence ... This paper discusses the right of a patient to refuse medical treatment and juxtaposes ... This is achieved by an expository review of relevant case law and scholarly ...

  20. Bacteria and Acidic Drainage from Coal Refuse: Inhibition by Sodium Lauryl Sulfate and Sodium Benzoate

    Science.gov (United States)

    Dugan, Patrick R.; Apel, William A.

    1983-01-01

    The application of an aqueous solution of sodium lauryl sulfate and sodium benzoate to the surface of high-sulfur coal refuse resulted in the inhibition of iron-and sulfur-oxidizing chemoautotrophic bacteria and in the decrease of acidic drainage from the refuse, suggesting that acid drainage can be abated in the field by inhibiting iron- and sulfur-oxidizing bacteria. PMID:16346347

  1. School refusal associated with separation anxiety disorder; an adolescent case report

    Directory of Open Access Journals (Sweden)

    Mustafa Yasin Irmak

    2016-12-01

    Full Text Available In literature, there are lots of studies about separation anxiety disorder (SAD and school refusal. Of the patients in these studies, it is generally known to child age group. In this paper, we aimed to draw attention to an adolescent patient with SAD who admitted to our clinic with complaint of school refusal and there is SAD under his unwillingness to go to school. [J Contemp Med 2016; 6(4.000: 357-360

  2. [Nursing ethics in the face of the refusal of nursing care].

    Science.gov (United States)

    Dauchy, Sarah; Charles, Cécile; Vérotte, Nelly; Block, Véronique; Adam, Virginie

    2016-10-01

    Caregivers can find themselves faced with a refusal of nursing care. A number of questions are then raised. While it is firstly important to understand the reasons for this refusal and what is at stake for the patient, there are a number of nursing strategies in place, not least of all dialogue and analysis. The role of the multi-disciplinary team is essential in such situations. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. Insulin therapy refusal among type II diabetes mellitus patients in Kubang Pasu district, Kedah, Malaysia

    Science.gov (United States)

    Tan, Wei Leong; Asahar, Siti Fairus; Harun, Noor Liani

    2015-01-01

    INTRODUCTION Diabetes mellitus is a rising non-communicable disease in Malaysia. Insulin therapy refusal is a challenge for healthcare providers, as it results in delayed insulin initiation. This study was conducted to determine the prevalence of insulin therapy refusal and its associated factors. METHODS This cross-sectional study was conducted at seven public health clinics in Kubang Pasu district of Kedah, Malaysia, from March to October 2012. A newly developed and validated questionnaire was used and participants were selected via systematic random sampling. Only patients diagnosed with type II diabetes mellitus (T2DM) and under the public health clinic care in Kubang Pasu were included in the study. Multiple logistic regression was used to study the association between insulin therapy refusal and its associated factors. RESULTS There were 461 respondents and the response rate was 100%. Among these 461 patients with T2DM, 74.2% refused insulin therapy. The most common reason given for refusal was a lack of confidence in insulin injection (85.4%). Multiple logistic regression revealed that respondents who had secondary education were 55.0% less likely to refuse insulin therapy than those who had primary education or no formal education (adjusted odds ratio [OR] 0.45, 95% confidence interval [CI] 0.25–0.82, p = 0.009). There was also a significant inverse association between glycated haemoglobin (HbA1c) level and insulin therapy refusal (adjusted OR 0.87, 95% CI 0.76–1.00, p = 0.047). CONCLUSION Insulin therapy refusal is common in Kubang Pasu. Educational status and HbA1c level should be taken into consideration when counselling patients on insulin therapy initiation. PMID:25532511

  4. Fire protection at hot laboratories: Prevention, surveillance and fire-fighting

    International Nuclear Information System (INIS)

    Chappellier, A.M.

    1976-01-01

    After pointing out that fire in a hot laboratory can be an important factor contributing to a radioactivity accident, the author briefly recalls the items to be taken into account in a fire hazard analysis. He then describes various important aspects of prevention, detection and fire-fighting which - at the French Commissariat a l'Energie Atomique - are governed by already defined rules or by guidelines which are sufficiently advanced to give a clear idea of the final conclusions to be drawn therefrom. From the point of view protection, the concept of fire sector has been evolved, at hot laboratories, becomes the fire and contamination sector, so as to ensure under all circumstances the containment of any radioactive materials dispersed in the premises on fire. Regarding fire detection, a study should be made on the constraints specific to the facility and liable to affect detector operation. These include ventilation, radiations, neutral or corrosive atmosphere, etc. As regards fire-fighting, two particular aspects are dealt with, namely the question of using water in case of fire and action to be taken concerning ventilation. A practical example - the protection of a ventilation system - is described. In conclusion the paper refers to the need for a thorough analysis specific to each hot laboratory, and to the importance of preparing an operational plan so as to avoid any dangerous improvisations in case of an accident. (author)

  5. Mid-21st-century climate changes increase predicted fire occurrence and fire season length, Northern Rocky Mountains, United States

    Science.gov (United States)

    Riley, Karin L.; Loehman, Rachel A.

    2016-01-01

    Climate changes are expected to increase fire frequency, fire season length, and cumulative area burned in the western United States. We focus on the potential impact of mid-21st-century climate changes on annual burn probability, fire season length, and large fire characteristics including number and size for a study area in the Northern Rocky Mountains. Although large fires are rare they account for most of the area burned in western North America, burn under extreme weather conditions, and exhibit behaviors that preclude methods of direct control. Allocation of resources, development of management plans, and assessment of fire effects on ecosystems all require an understanding of when and where fires are likely to burn, particularly under altered climate regimes that may increase large fire occurrence. We used the large fire simulation model FSim to model ignition, growth, and containment of wildfires under two climate scenarios: contemporary (based on instrumental weather) and mid-century (based on an ensemble average of global climate models driven by the A1B SRES emissions scenario). Modeled changes in fire patterns include increased annual burn probability, particularly in areas of the study region with relatively short contemporary fire return intervals; increased individual fire size and annual area burned; and fewer years without large fires. High fire danger days, represented by threshold values of Energy Release Component (ERC), are projected to increase in number, especially in spring and fall, lengthening the climatic fire season. For fire managers, ERC is an indicator of fire intensity potential and fire economics, with higher ERC thresholds often associated with larger, more expensive fires. Longer periods of elevated ERC may significantly increase the cost and complexity of fire management activities, requiring new strategies to maintain desired ecological conditions and limit fire risk. Increased fire activity (within the historical range of

  6. Aged refuse enhances anaerobic digestion of waste activated sludge.

    Science.gov (United States)

    Zhao, Jianwei; Gui, Lin; Wang, Qilin; Liu, Yiwen; Wang, Dongbo; Ni, Bing-Jie; Li, Xiaoming; Xu, Rui; Zeng, Guangming; Yang, Qi

    2017-10-15

    In this work, a low-cost alternative approach (i.e., adding aged refuse (AR) into waste activated sludge) to significantly enhance anaerobic digestion of sludge was reported. Experimental results showed that with the addition dosage of AR increasing from 0 to 400 mg/g dry sludge soluble chemical oxygen demand (COD) increased from 1150 to 5240 mg/L at the digestion time of 5 d, while the maximal production of volatile fatty acids (VFA) increased from 82.6 to 183.9 mg COD/g volatile suspended solids. Although further increase of AR addition decreased the concentrations of both soluble COD and VFA, their contents in these systems with AR addition at any concentration investigated were still higher than those in the blank, which resulted in higher methane yields in these systems. Mechanism studies revealed that pertinent addition of AR promoted solubilization, hydrolysis, and acidogenesis processes and did not affect methanogenesis significantly. It was found that varieties of enzymes and anaerobes in AR were primary reason for the enhancement of anaerobic digestion. Humic substances in AR benefited hydrolysis and acidogenesis but inhibited methanogenesis. The effect of heavy metals in AR on sludge anaerobic digestion was dosage dependent. Sludge anaerobic digestion was enhanced by appropriate amounts of heavy metals but inhibited by excessive amounts of heavy metals. The relative abundances of microorganisms responsible for sludge hydrolysis and acidogenesis were also observed to be improved in the system with AR addition, which was consistent with the performance of anaerobic digestion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Environment-friendly type energy and coordinated community development project. Feasibility study for industrialization of high efficiency waste-fired power generation system using general RDF; Kankyo chowagata energy community keisei sokushin. Kokoritsu haikibutsu hatsuden (ippainado RDF riyo) jigyoka FS chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The refuse-derived fuel (RDF) has been holding public attention not only as the energy resource of stable high calorific value for local energy development, but also as the effective method for waste treatment. As one of the effective utilization methods for waste treatment, this investigation was conducted to industrialize and establish the RDF power generation system, in which power generation and ash treatment are integrated in Tochigi Prefecture which is located inland. The base supply type was adopted as a way of operation from the menu of the electricity wholesale project of Tokyo Electric Power Co. and its rate of operation is 80 percent a year. Then, the fluidized bed combustion method, a dry exhaust gas treatment method, and continuous electric melting furnaces were decided as the RDF power generation system. According to this system, it is possible to obtain 26 percent gross thermal efficiency by conventional generation facilities. It was estimated that the expenses reduction for 15 years will be 17.6 billion yen compared with the ordinary combustion system. Also, the following effects can be expected; the reduction of CO2 emission, improvement of energy efficiency, and the extension of life of landfills capacity. 36 figs., 51 tabs.

  8. Informed consent for the administration of an intravenous contrast agent: importance and determinants of patient refusal

    International Nuclear Information System (INIS)

    Martel, J.; Garcia-Diaz, J. D.

    1999-01-01

    We proposed to determine the proportion of patients who refuse to undergo intravenous contrast administration and the factors that influence their refusal. Our series consisted of 442 patients who were supposed to undergo imaging studies involving the intravenous injection of an iodine contrast. In a personal interview, the patients were issued a questionnaire specifically designed for this study. The following parameters were recorded: sex, age, inpatient or outpatient status, medical history available, person who informed them about the procedure, person signing the informed consent (patient or other) , highest academic degree, attitude toward receiving the information and degree of concern after reading and signing the consent form. In our series 8.6% of the patients (95% confidence interval: 6-11.2) refused to sign the informed consent form. In addition, there were a number of patients who delayed the procedure or hindered the daily work schedule by some other means. When the relationship between each of the variables studied and refusal to sign the consent form was assessed, significant associations were observed between the latter and the academic level of the patient, his or her degree of concern and having received the information from a trained person. There was also a nearly significant trend toward the association between refusal and the patient's background. Relatively few patients refuse to sign the informed consent to receive intravenous contrast administration but this negative decision interferes with the health care practice. It is possible to identify certain correctable factors that influence the patient in this respect. (Author) 13 refs

  9. Comparing the quality of life in insulin recipient and refusal patients with type 2 diabetes.

    Science.gov (United States)

    Khalili, Mitra; Sabouhi, Fakhri; Abazari, Parvaneh; Aminorroaya, Ashraf

    2016-01-01

    Better control of blood sugar and reduction of diabetes complications through insulin therapy could convince people to choose this method. However, patients might refuse insulin therapy due to its painful injection, limitations in daily activities, and hypoglycemia. Thus, insulin therapy could have both positive and negative effects on patients' quality of life (QOL). Therefore, the aim of this study was to compare the QOL of insulin recipient and insulin refusal patients with type 2 diabetes. This study was a descriptive and comparative research conducted on 126 patients; 63 were insulin recipients and 63 had refused insulin therapy. Participants were under the care of the Endocrine and Metabolism Research Center of Isfahan, Iran. Data were gathered using the Diabetes Quality of Life (DQOL) questionnaire. In this tool, higher scores indicated lower QOL in patients. Data were analyzed using independent t-test, analysis of covariance, Mann-Whitney, Chi-square, and Pearson and Spearman's correlation. There was a significant difference (P refusal patients (mean = 1.74, SD = 0.41) in terms of mean QOL score. In addition, men and participants with higher educational levels reported a better QOL (P refusal patients had a better QOL. It seems that QOL is associated with the acceptance or refusal of insulin therapy. Therefore, enhancement of QOL could be related to all aspects of the disease, especially its treatment method and solving the therapeutic problems.

  10. Legislation and refusal of blood transfusion by a minor Jehovah-Witness in Belgium.

    Science.gov (United States)

    Deneyer, M; Matthys, D; Ramet, J; Michel, L; Holsters, D; Vandenplas, Y

    2011-01-01

    The refusal of blood transfusion by Jehovah's Witnesses in critical situations constitutes an ethical and juridical dilemma. The refusal to receive blood products by Jehovah's Witnesses is based on biblical verses. Recurring arguments to sustain this refusal regard the right to self-determination and the right to freedom of faith. If minors are involved, the problem is rendered even more difficult as the parental authority over young children needs to be taken into account. When adolescents are concerned, the situation if even more ambiguous since adolescents might be considered as mature enough to provide autonomous consent. On the basis of three cases, the most frequent bottlenecks that can come up in paediatric emergency services are highlighted: (1) the refusal of a blood transfusion by the parents of a young child; (2) the refusal by an adolescent and (3) prior refusal based on a "No Blood"-document. Regarding minors, the law on patients' rights in Belgium contains safety mechanisms concerning the preservation of physical integrity. Therefore, a key responsibility has been assigned to the physician. A step-by-step plan and a synoptic diagram are presented.

  11. Fires of sodium installations

    International Nuclear Information System (INIS)

    Hajek, L.; Tlalka, R.

    1984-01-01

    A survey is presented of the literature dealing with fires of sodium installations between 1974 and 1981. Also described are three experimental fires of ca 50 kg of sodium in an open area, monitored by UJV Rez. The experimental conditions of the experiments are described and a phenomenological description is presented of the course of the fires. The experiments showed a relationship between wind velocity in the area surrounding the fire and surface temperature of the sodium flame. Systems analysis methods were applied to sodium area, spray and tube fires. (author)

  12. Evaluating the sustainability of co-firing in the UK

    Energy Technology Data Exchange (ETDEWEB)

    Woods, Jeremy; Tipper, Richard; Brown, Gareth; Diaz-Chavez, Rocio; Lovell, Jessica; de Groot, Peter

    2006-10-09

    The objectives of the study were: Assess the overall carbon balance for co-firing; Investigate the other sustainability issues relating to co-firing; Assess the scope for incentivising the most sustainable forms of co-firing. The main questions to be addressed were: Is the overall carbon balance for co-firing positive? What is the difference in carbon balance between energy crops and other biomass? Are some kinds of energy crops better than others? How big a factor is transport in the carbon balance? Under what circumstances (fuel, transport, process, etc.) are the greatest benefits of co-firing in terms of carbon balance and sustainability? Are there any circumstances (as above) that could raise serious carbon balance or sustainability issues? How does the carbon balance compare between co-firing, dedicated biomass, and biomass heat? Is there any scope for encouraging the most sustainable forms of co-firing - perhaps through using existing or currently in development accreditation schemes? The report concludes that: Co-firing could be expanded to make a significant and low risk contribution to Government and EU renewable energy policy targets; Real environmental and social benefits could arise from the expansion of co-firing markets, both in the UK and in poor developing countries, given responsible development policy; There is no clear environmental or social case, for an arbitrary cap on the amount of co-firing; Co-firing could expand and enhance clean coal Carbon and Capture and Sequestration (CCS). This report focuses solely on the carbon (GHG) and broader sustainability impacts of co-firing in the UK. It does not include an economic evaluation. It provides an overview of the existing materials being used as feedstocks for co-firing and a summary life-cycle assessment of the GHG balances and sustainability (environmental and social) impacts of the provision and use of those feedstocks. A clear distinction is made between the use of residues and dedicated

  13. Evaluating the sustainability of co-firing in the UK

    International Nuclear Information System (INIS)

    Woods, Jeremy; Tipper, Richard; Brown, Gareth; Diaz-Chavez, Rocio; Lovell, Jessica; de Groot, Peter

    2006-01-01

    The objectives of the study were: Assess the overall carbon balance for co-firing; Investigate the other sustainability issues relating to co-firing; Assess the scope for incentivising the most sustainable forms of co-firing. The main questions to be addressed were: Is the overall carbon balance for co-firing positive? What is the difference in carbon balance between energy crops and other biomass? Are some kinds of energy crops better than others? How big a factor is transport in the carbon balance? Under what circumstances (fuel, transport, process, etc.) are the greatest benefits of co-firing in terms of carbon balance and sustainability? Are there any circumstances (as above) that could raise serious carbon balance or sustainability issues? How does the carbon balance compare between co-firing, dedicated biomass, and biomass heat? Is there any scope for encouraging the most sustainable forms of co-firing - perhaps through using existing or currently in development accreditation schemes? The report concludes that: Co-firing could be expanded to make a significant and low risk contribution to Government and EU renewable energy policy targets; Real environmental and social benefits could arise from the expansion of co-firing markets, both in the UK and in poor developing countries, given responsible development policy; There is no clear environmental or social case, for an arbitrary cap on the amount of co-firing; Co-firing could expand and enhance clean coal Carbon and Capture and Sequestration (CCS). This report focuses solely on the carbon (GHG) and broader sustainability impacts of co-firing in the UK. It does not include an economic evaluation. It provides an overview of the existing materials being used as feedstocks for co-firing and a summary life-cycle assessment of the GHG balances and sustainability (environmental and social) impacts of the provision and use of those feedstocks. A clear distinction is made between the use of residues and dedicated

  14. 76 FR 24467 - Fire Mountain Lodge; Notice of Application Accepted for Filing, Soliciting Motions To Intervene...

    Science.gov (United States)

    2011-05-02

    .... The existing Fire Mountain Lodge project consists of: (1) A 265- foot-long earth and concrete filled... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 1992-003] Fire Mountain.... Date filed: April 25, 2008. d. Applicant: Mr. Ken Willis. e. Name of Project: Fire Mountain Lodge. f...

  15. Building ways for energy supply of tomorrow. Climate-friendly coal-fired power plants by sequestration; Brueckenschlag zur Energieversorgung von morgen. Klimaschonende Kohlekraftwerke durch Sequestrierung

    Energy Technology Data Exchange (ETDEWEB)

    Dunker, Ralf

    2009-07-01

    Power plant manufacturers and electric utilities work hard for modern technologies which shall optimize climate protection and improve economic efficiency of coal fired power plants. Different ways of CCS (Carbon Capture and Storage) have to be checked to achieve the CO{sub 2}-free power plant. The best prospects in close future seems to have the Oxyfuel Method. Another project is presented, called Chilled-ammonia-process, also Carbon Dioxide separation by ammonia washing. Possibilities of different carbon dioxide storage are discussed taking always into account climate protection. (orig./GL)

  16. Fire retardant formulations

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to compositions where a substrate is liable to catch fire such as bituminous products, paints, carpets or the like. The invention relates to a composition comprising 40-95 weight % of a substrate to be rendered fire resistant such as bituminous material or paint......, carpets which substrate is mixed with 5-60 weight % of a fire retardant component. The invention relates to a fire retardant component comprising or being constituted of attapulgite, and a salt being a source of a blowing or expanding agent, where the attapulgite and the salt are electrostatically...... connected by mixing and subjecting the mixture of the two components to agitation. Also, the invention relates to compositions comprising 40-95 weight % of a substrate to be rendered fire resistant mixed with 5-60 weight % of a fire retardant according to claim 1 or 2, which fire retardant component...

  17. Fire risk in California

    Science.gov (United States)

    Peterson, Seth Howard

    Fire is an integral part of ecosystems in the western United States. Decades of fire suppression have led to (unnaturally) large accumulations of fuel in some forest communities, such as the lower elevation forests of the Sierra Nevada. Urban sprawl into fire prone chaparral vegetation in southern California has put human lives at risk and the decreased fire return intervals have put the vegetation community at risk of type conversion. This research examines the factors affecting fire risk in two of the dominant landscapes in the state of California, chaparral and inland coniferous forests. Live fuel moisture (LFM) is important for fire ignition, spread rate, and intensity in chaparral. LFM maps were generated for Los Angeles County by developing and then inverting robust cross-validated regression equations from time series field data and vegetation indices (VIs) and phenological metrics from MODIS data. Fire fuels, including understory fuels which are not visible to remote sensing instruments, were mapped in Yosemite National Park using the random forests decision tree algorithm and climatic, topographic, remotely sensed, and fire history variables. Combining the disparate data sources served to improve classification accuracies. The models were inverted to produce maps of fuel models and fuel amounts, and these showed that fire fuel amounts are highest in the low elevation forests that have been most affected by fire suppression impacting the natural fire regime. Wildland fires in chaparral commonly burn in late summer or fall when LFM is near its annual low, however, the Jesusita Fire burned in early May of 2009, when LFM was still relatively high. The HFire fire spread model was used to simulate the growth of the Jesusita Fire using LFM maps derived from imagery acquired at the time of the fire and imagery acquired in late August to determine how much different the fire would have been if it had occurred later in the year. Simulated fires were 1.5 times larger

  18. Effect of bio-column composed of aged refuse on methane abatement--a novel configuration of biological oxidation in refuse landfill.

    Science.gov (United States)

    Han, Dan; Zhao, Youcai; Xue, Binjie; Chai, Xiaoli

    2010-01-01

    An experimental bio-column composed of aged refuse was installed around the exhaust pipe as a new way to mitigate methane in refuse landfill. One of the objectives of this work was to assess the effect of aged refuse thickness in bio-column on reducing CH4 emissions. Over the study period, methane oxidation was observed at various thicknesses, 5 cm (small size), 10 cm (middle size) and 15 cm (large size), representing one to three times of pipeline diameters. The middle and large size both showed over 90% methane conversion, and the highest methane conversion rate of above 95% occurred in the middle-size column cell. Michaelis-Menten equation addressed the methanotrophs diffusion in different layers of the bio-columns. Maximum methanotrophic activity (Vmax) measured at the three thicknesses ranged from 6.4 x 10(-3) to 15.6 x 10(-3) units, and the half-saturation value (K(M)) ranged from 0.85% to 1.67%. Both the highest Vmax and K(M) were observed at the middle-size of the bio-column, as well as the largest methanotrophs population, suggesting a significant efficiency of methane mitigation happened in the optimum zone with greatest affinity and methanotrophic bacteria activities. Therefore, bio-column is a potential style for methane abatement in landfill, and the aged refuse both naturally formed and artificially placed in the column plays a critical role in CH4 emission.

  19. Nuclear energy cost data base. A reference data base for nuclear and coal-fired powerplant power-generation cost analysis

    International Nuclear Information System (INIS)

    1982-10-01

    A reference data base and standard methodology are needed for performing comparative nuclear and fossil power generation cost analyses for DOE/NE. Proposals are presented for such a methodology and for reference assumptions and data to be used with the methodology. This report is intended to provide basic guidelines or a starting point for analysis and to serve as a focal point in establishing parameters and methods to be used in economic comparisons of nuclear systems with alternatives. The data base is applicable for economic comparisons of new base-load light water reactors on either a current once-through cycle or self-generated recycle, high- and low-sulfur coal-fired plants, and oil and natural gas-fired electric generating plant coming on line in the last decade of this century. This paper includes a data base containing proposed technical and economic assumptions to be used in analyses, discussions of a recommended methodology to be used in calculating power generation costs, and a sample calculation for illustrative and benchmark purposes

  20. Fire Danger and Fire Weather Records

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The National Weather Service (formerly Weather Bureau) and Forest Service developed a program to track meteorological conditions conducive to forest fires, resulting...

  1. Nuclear Power Plant Fire Protection Research Program

    International Nuclear Information System (INIS)

    Datta, A.

    1985-07-01

    The goal is to develop test data and analytical capabilities to support the evaluation of: (1) the contribution of fires to the risk from nuclear power plants; (2) the effects of fires on control room equipment and operations; and (3) the effects of actuation of fire suppression systems on safety equipment. A range of fire sources will be characterized with respect to their energy and mass evolution, including smoke, corrosion products, and electrically conductive products of combustion. An analytical method for determining the environment resulting from fire will be developed. This method will account for the source characteristics, the suppression action following detection of the fire, and certain parameters specific to the plant enclosure in which the fire originates, such as the geometry of the enclosure and the ventilation rate. The developing local environment in the vicinity of safety-related equipment will be expressed in terms of temperatures, temperature rise rates, heat fluxes, and moisture and certain species content. The response of certain safe shutdown equipment and components to the environmental conditions will be studied. The objective will be to determine the limits of environmental conditions that a component may be exposed to without impairment of its ability to function

  2. Towards improved quantification of post-fire conifer mortality and recovery: Impacts of fire radiative flux on seedling and mature tree mortality, physiology, and growth

    Science.gov (United States)

    Sparks, A. M.; Kolden, C.; Smith, A. M.

    2016-12-01

    Fire activity, in terms of intensity, frequency, and total area burned, is expected to increase with changing climate. A challenge for landscape level assessment of fire effects, termed burn severity, is that current assessments provide very little information regarding vegetation physiological performance and recovery, limiting our understanding of fire effects on ecosystem services such as carbon storage/cycling. To address these limitations, we evaluated an alternative dose-response methodology for quantifying fire effects that attempts to bridge fire combustion dynamics and ecophysiology. Specifically, we conducted a highly controlled, laboratory assessment of seedling response to increasing doses of fire radiative energy applied through surface fires, for two western U.S. conifer species. Seedling physiology and spectral reflectance were acquired pre- and up to 1 year post-fire. Post-fire mortality, physiological performance, and spectral reflectance were strongly related with fire radiative energy density (FRED: J m-2) dose. To examine how these relationships change with tree size and age, we conducted small prescribed fires at the tree scale (35 m2) in a mature conifer stand. Radial growth and resin duct defenses were assessed on the mature conifer trees following the prescribed fires. Differences in dose-response relationships between seedlings and mature trees indicate the importance of fire behavior (e.g., flaming-dominated versus smoldering-dominated combustion) in characterizing these relationships. Ultimately, these results suggest that post-fire impacts on growth of surviving seedlings and mature trees require modes of heat transfer to impact tree canopies.

  3. All fired up

    CERN Multimedia

    CERN Bulletin

    2013-01-01

    Members of the Directorate and their support staff took part in a fire-fighting course organised by the CERN Fire Brigade just before the end-of-year break.  The Bulletin takes a look at the fire-fighting training on offer at CERN.   At CERN the risk of fire can never be under-estimated. In order to train personnel in the use of fire extinguishers, CERN's fire training centre in Prévessin acquired a fire-simulation platform in 2012. On the morning of 17 December 2012, ten members of the CERN directorate and their support staff tried out the platform, following in the footsteps of 400 other members of the CERN community who had already attended the course. The participants were welcomed to the training centre by Gilles Colin, a fire-fighter and instructor, who gave them a 30-minute introduction to general safety and the different types of fire and fire extinguishers, followed by an hour of practical instruction in the simulation facility. There they were able to pract...

  4. Wildland Fire Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Green,T.

    2009-10-23

    This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) updates the 2003 plan incorporating changes necessary to comply with DOE Order 450.1 and DOE P 450.4, Federal Wildland Fire Management Policy and Program Review; Wildland and Prescribed Fire Management Policy and implementation Procedures Reference Guide. This current plan incorporates changes since the original draft of the FMP that result from new policies on the national level. This update also removes references and dependence on the U.S. Fish & Wildlife Service and Department of the Interior, fully transitioning Wildland Fire Management responsibilities to BNL. The Department of Energy policy for managing wildland fires requires that all areas, managed by the DOE and/or its various contractors, that can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wild fire, operational, and prescribed fires. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, 'prescribed' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of the DOE and BNL. This Fire Management Plan is presented in a format that coverers all aspects specified by DOE guidance documents which are based on the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. This FMP is to be used and implemented for the

  5. Safety study of fire protection for nuclear fuel cycle facility

    International Nuclear Information System (INIS)

    2013-01-01

    Insufficiencies in the fire protection system of the nuclear reactor facilities were pointed out when the fire occurred due to the Niigata prefecture-Chuetsu-oki Earthquake in July, 2007. This prompted the revision of the fire protection safety examination guideline for nuclear reactors as well as commercial guidelines. The commercial guidelines have been endorsed by the regulatory body. Now commercial fire protection standards for nuclear facilities such as the design guideline and the management guideline for protecting fire in the Light Water Reactors (LWRs) are available, however, those to apply to the nuclear fuel cycle facilities such as mixed oxide fuel fabrication facility (MFFF) have not been established. For the improvement of fire protection system of the nuclear fuel cycle facilities, the development of a standard for the fire protection, corresponding to the commercial standard for LWRs were required. Thus, Japan Nuclear Energy Safety Organization (JNES) formulated a fire protection guidelines for nuclear fuel cycle facilities as a standard relevant to the fire protection of the nuclear fuel cycle facilities considering functions specific to the nuclear fuel cycle facilities. In formulating the guidelines, investigation has been conduced on the commercial guidelines for nuclear reactors in Japan and the standards relevant to the fire protection of nuclear facilities in USA and other countries as well as non-nuclear industrial fire protection standards. The guideline consists of two parts; Equipments and Management, as the commercial guidances of the nuclear reactor. In addition, the acquisition of fire evaluation data for a components (an electric cabinet, cable, oil etc.) targeted for spread of fire and the evaluation model of fire source were continued for the fire hazard analysis (FHA). (author)

  6. Predictors of condom use and refusal among the population of Free State province in South Africa.

    Science.gov (United States)

    Chandran, Thoovakkunon Moorkoth; Berkvens, Dirk; Chikobvu, Perpetual; Nöstlinger, Christiana; Colebunders, Robert; Williams, Brian Gerard; Speybroeck, Niko

    2012-05-28

    This study investigated the extent and predictors of condom use and condom refusal in the Free State province in South Africa. Through a household survey conducted in the Free Sate province of South Africa, 5,837 adults were interviewed. Univariate and multivariate survey logistic regressions and classification trees (CT) were used for analysing two response variables 'ever used condom' and 'ever refused condom'. Eighty-three per cent of the respondents had ever used condoms, of which 38% always used them; 61% used them during the last sexual intercourse and 9% had ever refused to use them. The univariate logistic regression models and CT analysis indicated that a strong predictor of condom use was its perceived need. In the CT analysis, this variable was followed in importance by 'knowledge of correct use of condom', condom availability, young age, being single and higher education. 'Perceived need' for condoms did not remain significant in the multivariate analysis after controlling for other variables. The strongest predictor of condom refusal, as shown by the CT, was shame associated with condoms followed by the presence of sexual risk behaviour, knowing one's HIV status, older age and lacking knowledge of condoms (i.e., ability to prevent sexually transmitted diseases and pregnancy, availability, correct and consistent use and existence of female condoms). In the multivariate logistic regression, age was not significant for condom refusal while affordability and perceived need were additional significant variables. The use of complementary modelling techniques such as CT in addition to logistic regressions adds to a better understanding of condom use and refusal. Further improvement in correct and consistent use of condoms will require targeted interventions. In addition to existing social marketing campaigns, tailored approaches should focus on establishing the perceived need for condom-use and improving skills for correct use. They should also incorporate

  7. An audit of consent refusals in clinical research at a tertiary care center in India

    Directory of Open Access Journals (Sweden)

    S J Thaker

    2015-01-01

    Full Text Available Background and Rationale: Ensuring research participants′ autonomy is one of the core ethical obligations of researchers. This fundamental principle confers on every participant the right to refuse to take part in clinical research, and the measure of the number of consent refusals could be an important metric to evaluate the quality of the informed consent process. This audit examined consent refusals among Indian participants in clinical studies done at our center. Materials and Methods: The number of consent refusals and their reasons in 10 studies done at our center over a 5-year period were assessed. The studies were classified by the authors according to the type of participant (healthy vs patients, type of sponsor (investigator-initiated vs pharmaceutical industry, type of study (observational vs interventional, level of risk [based on the Indian Council of Medical Research (ICMR "Ethical Guidelines for Biomedical Research on Human Participants"], available knowledge of the intervention being studied, and each patient′s disease condition. Results: The overall consent refusal rate was 21%. This rate was higher among patient participants [23.8% vs. healthy people (14.9%; P = 0.002], in interventional studies [33.6% vs observational studies (7.5%; P < 0.0001], in pharmaceutical industry-sponsored studies [34.7% vs investigator-initiated studies (7.2%; P < 0.0001], and in studies with greater risk (P < 0.0001. The most common reasons for consent refusals were multiple blood collections (28%, inability to comply with the study protocol (20%, and the risks involved (20%. Conclusion: Our audit suggests the adequacy and reasonable quality of the informed consent process using consent refusals as a metric.

  8. Refusal of hemodialysis by hospitalized chronic kidney disease patients in Pakistan.

    Science.gov (United States)

    Shafi, Salman Tahir; Saleem, Mohammad; Anjum, Roshina; Abdullah, Wajid; Shafi, Tahir

    2018-01-01

    In Pakistan, patients with chronic kidney disease (CKD) are commonly diagnosed at a late stage. There is little information about the refusal of hemodialysis by hospitalized CKD patients who need hemodialysis (HD) and reasons for acceptance and refusal among these patients. All patients with Stage V CKD who had medical indications to undergo HD and were hospitalized at a tertiary care facility over a six-month period were invited to participate in this study. Patients were surveyed regarding acceptance or refusing of HD and reasons for their decisions. Demographic, socioeconomic, and clinical characteristics of patients were compared between patients who accepted or refused HD. A total of 125 patients were included in the study. The mean age of the patients was 47.9 ±12.1 years. The mean duration of diagnosis of CKD was 2.5 ± 0.6 months. Of all patients, 72 (57.6%) agreed to do HD and 53 (42.4%) refused HD. Patients with arteriovenous fistula in place (27.1 vs. 9.1%, P 0.02) and those in the middle- or higher-income group (64.4% vs. 38.6%, p = 0.03) were more willing to undergo HD. Trust in doctor's advice (86.1%) was the most common reason for acceptance of HD. Frequency of HD per week (52.8%), lifelong and permanent nature of HD (50.9%), advice by family members or friends (37.7%), perception of poor quality of life on HD (35.8%), and fear of HD needles and complications during HD (33.9%) were the most common reasons for refusal. Refusal of HD is common among hospitalized CKD patients with medical indications to undergo HD, especially in lower income group.

  9. Managing wildland fires: integrating weather models into fire projections

    Science.gov (United States)

    Anne M. Rosenthal; Francis Fujioka

    2004-01-01

    Flames from the Old Fire sweep through lands north of San Bernardino during late fall of 2003. Like many Southern California fires, the Old Fire consumed susceptible forests at the urban-wildland interface and spread to nearby city neighborhoods. By incorporating weather models into fire perimeter projections, scientist Francis Fujioka is improving fire modeling as a...

  10. Assessment of forest biomass for use as energy. GIS-based analysis of geographical availability and locations of wood-fired power plants in Portugal

    Science.gov (United States)

    H. Viana; Warren B. Cohen; D. Lopes; J. Aranha

    2010-01-01

    Following the European Union strategy concerning renewable energy (RE), Portugal established in their national policy programmes that the production of electrical energy from RE should reach 45% of the total supply by 2010. Since Portugal has large forest biomass resources, a significant part of this energy will be obtained from this source. In addition to the two...

  11. Electrical Switchgear Building No. 5010-ESF Fire Hazards Technical Report

    International Nuclear Information System (INIS)

    N.M. Ruonavaara

    2001-01-01

    The purpose of this Fire Hazards Analysis Technical Report (hereinafter referred to as Technical Report) is to assess the risk from fire within individual fire areas to ascertain whether the U.S. Department of Energy (DOE) fire safety objectives are met. The objectives, identified in DOE Order 420.1, Change 2, Fire Safety, Section 4.2, establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: (1) The occurrence of a fire or related event; (2) A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of the employees, the public, and the environment; (3) Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards; (4) Property losses from a fire and related events exceeding defined limits established by DOE; and (5) Critical process controls and safety class systems being damaged as a result of a fire and related event

  12. Biological and geophysical feedbacks with fire in the Earth system

    Science.gov (United States)

    Archibald, S.; Lehmann, C. E. R.; Belcher, C. M.; Bond, W. J.; Bradstock, R. A.; Daniau, A.-L.; Dexter, K. G.; Forrestel, E. J.; Greve, M.; He, T.; Higgins, S. I.; Hoffmann, W. A.; Lamont, B. B.; McGlinn, D. J.; Moncrieff, G. R.; Osborne, C. P.; Pausas, J. G.; Price, O.; Ripley, B. S.; Rogers, B. M.; Schwilk, D. W.; Simon, M. F.; Turetsky, M. R.; Van der Werf, G. R.; Zanne, A. E.

    2018-03-01

    Roughly 3% of the Earth’s land surface burns annually, representing a critical exchange of energy and matter between the land and atmosphere via combustion. Fires range from slow smouldering peat fires, to low-intensity surface fires, to intense crown fires, depending on vegetation structure, fuel moisture, prevailing climate, and weather conditions. While the links between biogeochemistry, climate and fire are widely studied within Earth system science, these relationships are also mediated by fuels—namely plants and their litter—that are the product of evolutionary and ecological processes. Fire is a powerful selective force and, over their evolutionary history, plants have evolved traits that both tolerate and promote fire numerous times and across diverse clades. Here we outline a conceptual framework of how plant traits determine the flammability of ecosystems and interact with climate and weather to influence fire regimes. We explore how these evolutionary and ecological processes scale to impact biogeochemical and Earth system processes. Finally, we outline several research challenges that, when resolved, will improve our understanding of the role of plant evolution in mediating the fire feedbacks driving Earth system processes. Understanding current patterns of fire and vegetation, as well as patterns of fire over geological time, requires research that incorporates evolutionary biology, ecology, biogeography, and the biogeosciences.

  13. Direct carbon emissions from Canadian forest fires, 1959-1999

    International Nuclear Information System (INIS)

    Amiro, B. D.; Todd, J. B.; Flannigan, M. D.; Hirsch, K. G.; Wotton, B. M.; Logan, K. A.; Stocks, B. J.; Mason, J. A.; Martell, D. L.

    2001-01-01

    Fire is recognised as driving most of the boreal forest carbon balance in North America, therefore fires not only impact on carbon sequestration by forests, but emit greenhouse gases that have the potential to affect the environment. In this paper direct emissions of carbon from Canadian forest fires were estimated for all of Canada and for each ecozone for the period 1959 to 1999. Estimates were based on large fires ; fuel consumption for each fire was calculated using the Canadian Forest Fire Behaviour Prediction System. There were about 11,400 forest fires, averaging 2 x 10 6 hectare per year during this period. Boreal and taiga areas experienced the greatest area burned, releasing most of the carbon. The mean area-weighted fuel consumption for all fires was 2.6 kg of dry fuel per m 2 (1.3 kg carbon per m 2 ) varying from 1.8 kg to 3.9 kg per m 2 among ecozones. The mean annual direct carbon emission was estimated at 27 + or - 6 Tg carbon per year, or about 18 per cent of current carbon dioxide emissions from the Canadian energy sector, on average. This excludes post-fire effects, which cause an additional loss of carbon; changes to the forest also affect the strength of the forest carbon sink. Fire emissions have shown an increase over the past two decades and are likely to remain high due to anticipated changes in fire weather resulting from climate warming. 48 refs., 3 tabs., 6 figs

  14. Scaling up the microwave firing of ceramics

    International Nuclear Information System (INIS)

    Wroe, F.C.R.

    1993-01-01

    EA Technology, through a comprehensive R ampersand D program, is developing new microwave furnace technology focused on the ceramics processing industries. Using a combination of computer modelling, experimentation and feasibility studies, EA Technology has developed processes and procedures for firing large ceramic components. The aim of this work is to describe the investigation of the firing of ceramic products such as bricks, pottery, refractories, and industrial ceramics, using advanced processing techniques to produce and maintain uniformity of temperature throughout the components and kiln environment. This has achieved the goal of producing uniform microstructures and low thermal stress by careful control of the firing cycle. This paper illustrates the feasibility of microwave-assisted firing and shows it to be economically viable in terms of energy costs and process control. 6 refs., 1 fig

  15. Fire safety analysis: methodology

    International Nuclear Information System (INIS)

    Kazarians, M.

    1998-01-01

    From a review of the fires that have occurred in nuclear power plants and the results of fire risk studies that have been completed over the last 17 years, we can conclude that internal fires in nuclear power plants can be an important contributor to plant risk. Methods and data are available to quantify the fire risk. These methods and data have been subjected to a series of reviews and detailed scrutiny and have been applied to a large number of plants. There is no doubt that we do not know everything about fire and its impact on a nuclear power plants. However, this lack of knowledge or uncertainty can be quantified and can be used in the decision making process. In other words, the methods entail uncertainties and limitations that are not insurmountable and there is little or no basis for the results of a fire risk analysis fail to support a decision process

  16. Little Bear Fire Summary Report

    Science.gov (United States)

    Sarah McCaffrey; Melanie Stidham; Hannah. Brenkert-Smith

    2013-01-01

    In June 2012, immediately after the Little Bear Fire burned outside Ruidoso, New Mexico, a team of researchers interviewed fire managers, local personnel, and residents to understand perceptions of the event itself, communication, evacuation, and pre-fire preparedness. The intensity of fire behavior and resulting loss of 242 homes made this a complex fire with a...

  17. Fire management in central America

    Science.gov (United States)

    Andrea L. Koonce; Armando González-Cabán

    1992-01-01

    Information on fire management operations in Central America is scant. To evaluate the known level of fire occurrence in seven countries in that area, fire management officers were asked to provide information on their fire control organizations and on any available fire statistics. The seven countries surveyed were Guatemala, Belize, Honduras, El Salvador, Nicaragua,...

  18. The human and fire connection

    Science.gov (United States)

    Theresa B. Jain

    2014-01-01

    We refer to fire as a natural disturbance, but unlike other disturbances such as forest insects and diseases, fire has had an intimate relationship with humans. Fire facilitated human evolution over two million years ago when our ancestors began to use fire to cook. Fire empowered our furbearers to adapt to cold climates, allowing humans to disperse and settle into...

  19. Designing fire safe interiors.

    Science.gov (United States)

    Belles, D W

    1992-01-01

    Any product that causes a fire to grow large is deficient in fire safety performance. A large fire in any building represents a serious hazard. Multiple-death fires almost always are linked to fires that grow quickly to a large size. Interior finishes have large, continuous surfaces over which fire can spread. They are regulated to slow initial fire growth, and must be qualified for use on the basis of fire tests. To obtain meaningful results, specimens must be representative of actual installation. Variables--such as the substrate, the adhesive, and product thickness and density--can affect product performance. The tunnel test may not adequately evaluate some products, such as foam plastics or textile wall coverings, thermoplastic materials, or materials of minimal mass. Where questions exist, products should be evaluated on a full-scale basis. Curtains and draperies are examples of products that ignite easily and spread flames readily. The present method for testing curtains and draperies evaluates one fabric at a time. Although a fabric tested alone may perform well, fabrics that meet test standards individually sometimes perform poorly when tested in combination. Contents and furnishings constitute the major fuels in many fires. Contents may involve paper products and other lightweight materials that are easily ignited and capable of fast fire growth. Similarly, a small source may ignite many items of furniture that are capable of sustained fire growth. Upholstered furniture can reach peak burning rates in less than 5 minutes. Furnishings have been associated with many multiple-death fires.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Use of wet FGD material for revegetation of an abandoned acidic coal refuse pile

    International Nuclear Information System (INIS)

    Mafi, S.; Stehouwer, R.C.

    1996-01-01

    Wet FGD material has a neutralizing potential of 15% CaCO 3 . These properties may make it a beneficial amendment for revegetation of hyper-acidic coal refuse. In greenhouse and field experiments, coal refuse (pH = 2.5) was amended with wet FGD (300, 500, and 700 tons/acre). Amendment with FGD was as effective as agricultural lime (AL) in increasing refuse pH and decreasing soluble Al and Fe. Addition of compost to the FGD further increased pH and decreased soluble Al and Fe. Downward transport of Ca was greater with FGD than AL, but FGD did not increase leachate concentrations of S. Amendment with FGD increased refuse, leachate and plant tissue concentrations of B. Other trace elements were not increased by FGD. In the greenhouse, plant growth was similar with AL and FGD except during the first three months when AL produced more growth than FGD. The initial growth suppression by FGD was likely due to high soluble salts, and possibly by high B concentrations. During the first year of the field experiment plant growth was greater with FGD than with AL. In both the field and greenhouse experiments compost increased plant growth when combined with FGD. These experiments show revegetation of toxic coal refuse and improvement in drainage water quality is possible by amendment with FGD. Revegetation success will be improved by combined amendment with FGD and compost

  1. Parental psychological symptoms and familial risk factors of children and adolescents who exhibit school refusal.

    Science.gov (United States)

    Bahali, K; Tahiroglu, A Y; Avci, A; Seydaoglu, G

    2011-12-01

    To assess the levels of psychological symptoms in the parents of children with school refusal and determine the familial risk factors in its development. This study was performed on 55 pairs of parents who had children exhibiting school refusal and were compared with a control group. A socio-demographic data form, the Beck Depression Inventory, the State-Trait Anxiety Inventory, and the Symptom Checklist-90 revised were applied to these parents. Parents of the school refusal group had higher anxiety and depression scores than the controls. Among the risk factors for school refusal, physical punishment by the parents, a history of organic disease in the parents or children, and a history of psychiatric disorders in the parents or other relatives were found to be significant. Depending on genetic and environmental factors, parents with psychiatric disorders appeared to be associated with development of psychiatric disorders in their children. Moreover, psychiatric disorders in parents negatively affected the treatment of their children and adolescents who exhibited school refusal. It is therefore vital to treat psychiatric disorders of parents with the children having psychiatric disorders, and thus increase parent participation in their children's therapeutic process.

  2. Childhood vaccine refusal and hesitancy intentions in Croatia: insights from a population-based study.

    Science.gov (United States)

    Repalust, Anja; Šević, Sandra; Rihtar, Stanko; Štulhofer, Aleksandar

    2017-10-01

    Considering that programmatic data suggest a recent rise in vaccine refusal in Croatia, this study, first of its kind in Southeast Europe, aimed to estimate the prevalence, and sociodemographic, and sociocultural determinants of childhood vaccine refusal and hesitancy (CVRH) intentions among Croatian adults. Multi-stage stratified population-based survey included 1000 individuals aged 18-88 years (M age  = 47.7, SD = 17.8), of whom 51.7% were women. The outcome, a categorical indicator, distinguished among individuals who would approve vaccinating their children (vaccine accepting), those who would approve some but not all vaccines (vaccine hesitant), and those who would refuse vaccination (vaccine refusing). A sizeable minority of participants was characterized by childhood vaccine refusal (10.6%) and hesitancy intentions (19.5%). In a multivariate assessment controlling for parenthood, the odds of vaccine hesitancy were significantly increased by a younger age (AOR = 1.96-3.03, p Croatia. Following the social contagion model, future research should move beyond individual-level approach and take into account social interaction and social network effects.

  3. Transitional paternalism: how shared normative powers give rise to the asymmetry of adolescent consent and refusal.

    Science.gov (United States)

    Manson, Neil C

    2015-02-01

    In many jurisdictions, adolescents acquire the right to consent to treatment; but in some cases their refusals - e.g. of life-saving treatment - may not be respected. This asymmetry of adolescent consent and refusal seems puzzling, even incoherent. The aim here is to offer an original explanation, and a justification, of this asymmetry. Rather than trying to explain the asymmetry in terms of a variable standard of competence - where the adolescent is competent to consent to, but not refuse, certain interventions - the account offered here focuses more closely on the normative power to render actions permissible. Where normative powers are shared they can readily give rise to an asymmetry between consent and refusal. We then turn to why it is justifiable that normative powers be shared in adolescence. Transitional paternalism holds that the acquisition of normative powers by competent adolescents should not be an instant one, achieved in a single step, but that there should be a transitional period where paternalistic protection is rolled back, but not entirely withdrawn until a later date. Transitional paternalism could be implemented without generating the asymmetry between consent and refusal but, it is argued, the asymmetric version of transitional paternalism is to be preferred insofar as it offers a greater respect for the adolescent's decisions than the symmetrical alternative. © 2014 John Wiley & Sons Ltd.

  4. Are they really refusing to travel? A qualitative study of prehospital records

    Directory of Open Access Journals (Sweden)

    Christopher Sarah

    2006-09-01

    Full Text Available Abstract Background Refusal by the patient to travel after calling an emergency ambulance may lead to a preventable waste of scarce resources if it can be shown that an alternative more appropriate response could be employed. A greater understanding is required of the reasons behind 'refusal to travel' (RTT in order to find appropriate solutions to address this issue. We sought to investigate the reasons why patients refuse to travel following emergency call-out in a rural county. Methods Written records made by ambulance crews for patients (n = 397 who were not transported to hospital following an emergency call-out during October 2004 were retrospectively analysed. Results Twelve main themes emerged for RTT which included non injury or minor injury, falls and recovery after treatment on scene; other themes included alternative supervision, follow-up and treatment arrangements or patients arranging their own transport. Importantly, only 8% of the sample was recorded by ambulance crews as truly refusing to travel against advice. Conclusion A system that facilitates standardised recording of RTT information including social reasons for non-transportation needs to be designed. 'Refused to travel' disclaimers need to reflect instances when crew and patient are satisfied that not going to hospital is the right outcome. These recommendations should be considered within the context of the plans for widening the role of ambulance services.

  5. [Refusal of care faced by case manager from elderly persons in complex situation: cross perspectives].

    Science.gov (United States)

    Corvol, A; Balard, F; Moutel, G; Somme, D

    2014-01-01

    Case management is a new professional field in France. It is addressed to elderly persons living in community whose situation is regarded as particularly complex. Case managers have to assess needs and coordinate necessary services. One common criteria of complexity is refusal of care. The objective of this study is to compare the words of users with those of case managers about refusal of care, in order to understand its meaning, professionals' attitudes and ethical challenges. Two researchers have cooperated on this qualitative research: the first one, anthropologist, interviewed 19 individuals, and 11 of their caregivers. The second one, geriatrician and researcher in medical ethics, lead four focus groups gathering a total of 18 case managers. Refusal of care often is the result of the will of preserving one's identity, compromised by illness. Individuals seek control on their life. Facing this behaviour, case managers try to secure the individual, by establishing a personal relationship that respects their choices, even if care has to be delayed. Refusal of care may sometimes disclose a desire to vanish, in front of which professionals meet their own limits. To recognise an elderly person that refuses care as a unique individual who can make choices secure his identity, and allow him to change. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  6. A comparative life cycle assessment of diesel and compressed natural gas powered refuse collection vehicles in a Canadian city

    International Nuclear Information System (INIS)

    Rose, Lars; Hussain, Mohammed; Ahmed, Syed; Malek, Kourosh; Costanzo, Robert; Kjeang, Erik

    2013-01-01

    Consumers and organizations worldwide are searching for low-carbon alternatives to conventional gasoline and diesel vehicles to reduce greenhouse gas (GHG) emissions and their impact on the environment. A comprehensive technique used to estimate overall cost and environmental impact of vehicles is known as life cycle assessment (LCA). In this article, a comparative LCA of diesel and compressed natural gas (CNG) powered heavy duty refuse collection vehicles (RCVs) is conducted. The analysis utilizes real-time operational data obtained from the City of Surrey in British Columbia, Canada. The impact of the two alternative vehicles is assessed from various points in their life. No net gain in energy use is found when a diesel powered RCV is replaced by a CNG powered RCV. However, significant reductions (approximately 24% CO 2 -equivalent) in GHG and criteria air contaminant (CAC) emissions are obtained. Moreover, fuel cost estimations based on 2011 price levels and a 5-year lifetime for both RCVs reveal that considerable cost savings may be achieved by switching to CNG vehicles. Thus, CNG RCVs are not only favorable in terms of reduced climate change impact but also cost effective compared to conventional diesel RCVs, and provide a viable and realistic near-term strategy for cities and municipalities to reduce GHG emissions. - Highlights: ► Life cycle analysis is performed on two alternative refuse collection vehicle technologies. ► Real-time operational data obtained by the City of Surrey in British Columbia are utilized. ► The life cycle energy use is similar for diesel and CNG RCVs. ► A 24% reduction of GHG emissions (CO 2 -equivalent) may be realized by switching from diesel to CNG. ► CNG RCVs are estimated to be cost effective and may lead to reduced fuel costs.

  7. WebFIRE

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Factor Information Retrieval (FIRE) Data System is a database management system containing EPA's recommended emission estimation factors for criteria and...

  8. Fire safety engineering

    International Nuclear Information System (INIS)

    Smith, D.N.

    1989-01-01

    The periodic occurrence of large-scale, potentially disastrous industrial accidents involving fire in hazardous environments such as oilwell blowouts, petrochemical explosions and nuclear installations highlights the need for an integrated approach to fire safety engineering. Risk reduction 'by design' and rapid response are of equal importance in the saving of life and property in such situations. This volume of papers covers the subject thoroughly, touching on such topics as hazard analysis, safety design and testing, fire detection and control, and includes studies of fire hazard in the context of environment protection. (author)

  9. Modeling of compartment fire

    International Nuclear Information System (INIS)

    Sathiah, P.; Siccama, A.; Visser, D.; Komen, E.

    2011-01-01

    Fire accident in a containment is a serious threat to nuclear reactors. Fire can cause substantial loss to life and property. The risk posed by fire can also exceed the risk from internal events within a nuclear reactor. Numerous research efforts have been performed to understand and analyze the phenomenon of fire in nuclear reactor and its consequences. Modeling of fire is an important subject in the field of fire safety engineering. Two approaches which are commonly used in fire modeling are zonal modeling and field modeling. The objective of this work is to compare zonal and field modeling approach against a pool fired experiment performed in a well-confined compartment. Numerical simulations were performed against experiments, which were conducted within PRISME program under the framework of OECD. In these experiments, effects of ventilation flow rate on heat release rate in a confined and mechanically ventilated compartment is investigated. Time dependent changes in gas temperature and oxygen mass fraction were measured. The trends obtained by numerical simulation performed using zonal model and field model compares well with experiments. Further validation is needed before this code can be used for fire safety analyses. (author)

  10. Outcomes of nighttime refusal of admission to the intensive care unit: The role of the intensivist in triage.

    Science.gov (United States)

    Hinds, Nicholas; Borah, Amit; Yoo, Erika J

    2017-06-01

    To compare outcomes of patients refused medical intensive care unit (MICU) admission overnight to those refused during the day and to examine the impact of the intensivist in triage. Retrospective, observational study of patients refused MICU admission at an urban university hospital. Of 294 patients, 186 (63.3%) were refused admission overnight compared to 108 (36.7%) refused during the day. Severity-of-illness by the Mortality Probability Model was similar between the two groups (P=.20). Daytime triage refusals were more likely to be staffed by an intensivist (P=.01). After risk-adjustment, daytime refusals had a lower odds of subsequent ICU admission (OR 0.46, 95% CI 0.22-0.95, P=.04) than patients triaged at night. There was no evidence for interaction between time of triage and intensivist staffing of the patient (P=.99). Patients refused MICU admission overnight are more likely to be later admitted to an ICU than patients refused during the day. However, the mechanism for this observation does not appear to depend on the intensivist's direct evaluation of the patient. Further investigation into the clinician-specific effects of ICU triage and identification of potentially modifiable hospital triage practices will help to improve both ICU utilization and patient safety. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Combustion of Refuse Derived Fuels; Foerbraenning av utsorterade avfallsfraktioner

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Magnus; Wikman, Karin [AaF-Energi och Miljoe, Stockholm (Sweden); Andersson, Christer; Myringer, Aase; Helgesson, Anna [Vattenfall Utveckling AB, Aelvkarleby (Sweden); Eskilsson, David; Ekvall, Annika [SP Swedish National Testing and Research Inst., Boraas (Sweden); Oehman, Marcus; Geyter, Sigrid de [Umeaa Univ. (Sweden). Energy Technology and Thermal Process Chemistry

    2005-03-01

    The aim of this project was to increase the understanding of opportunities and problems connected with combustion of sorted waste fractions containing paper, wood and plastics (PWP-fuel) in fluidized bed boilers. An evaluation of the effect of sulphur containing additives in a PWP-fuel fired boiler was also performed within the project since this is not previously reported in open literature. The experience from two boilers at different plants, Johannes (BFB) and Hoegdalen P6 (CFB) during the firing season 2003/2004 was documented. In the Johannes boiler the main fuel is bark while Hoegdalen P6 combusts 100 % PWP-fuel. Analysis of the fuels shows that there are large differences between the two boilers. At Johannes the PWP-fuel contained low amounts of elements (chlorine, alkali and other metals) that are expected to result in increased operational problems or emissions. A large proportion of these unwanted elements came from the wood and paper fractions. The plastic fraction in Johannes had very low levels of unwanted elements. The fuel at Hoegdalen contained large amounts of elements such as chlorine, alkali and other metals that can cause operational problems. First of all the plastic fraction contained large amounts of chlorine, most likely from PVC, which results in a more corrosive atmosphere in the boiler. The fraction of fines in the Hoegdalen fuel contained larger concentrations of potassium and sodium compared with the other fuel fractions, substances that also are related to the formation of deposits. The fraction of fines in the fuel probably also results in combustion taking place high up in the boiler and to some extent continuing in the cyclones. The characterisation of the combustion behaviour performed in Johannes identified a maldistribution in O{sub 2}, CO and gas temperature over a cross-section of the furnace. This was not depending on the fuel mixture but is more likely depending on uneven fuel feeding or air distribution. A comparison between

  12. Refusing to stay down for the short count

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Atomic Industrial Forum does not agree that nuclear power is dead because it sees that many public attitudes do not correlate with reality. The pro-nuclear Reagan administration, however, was not able to overcome many of the regulatory and economic obstacles, and many of the personnel and budget changes have not been as pro-industry as the public expected. The 78 licensed nuclear plant produced 285 billion kilowatthours of electric power during 1981, for an 8.5% increase in output that was twice the expansion of coal-fired power. There were no serious safety-related events, although operating capacity factor rose from 59.3% in 1980 to 61%. The flat growth in power consumption as a whole was more a reflection of the economy than the effects of conservation. Low-level waste management prohibitions or restrictions are in effect in 18 states, while Congress focuses on high-level wastes. The year was not productive for the anti-nuclear movement as the debate continues to shift from emotional to economic and technical issues. The report includes a state-by-state summary of nuclear plants, a status report on new projects, and a 10-year profile of installed capacity. 1 figure, 2 tables

  13. Smoking and Home Fire Safety

    Science.gov (United States)

    ... Materials Working with the Media Fire Protection Technology Smoking fire safety outreach materials As a member of ... Not reported 7% In transport 1% 195 incidents Smoking fire safety messages to share It is important ...

  14. Confusing criminal and civil law: when may a hospital refuse to release a dead body?

    Science.gov (United States)

    Gallagher, Steven B

    2014-12-01

    A United Kingdom bereavement advice group has expressed concern that hospitals in Britain may be acting "illegally" in refusing to release dead bodies to relatives unless they provide evidence that funeral arrangements have been made. In some cases, hospitals may have refused to release a body to anyone other than an undertaker. The charity argues that this behaviour constitutes the common law offence of preventing the lawful burial of a body. This article considers the confusion that may occur between this offence and interference with the right to possession of a body for lawful burial. The conclusion is that it is extremely unlikely a hospital or its employees would fall foul of the criminal law in refusing to release a dead body and may be liable in the civil courts if they release a body to someone who does not have the duty and consequent right to possession of the body for lawful burial.

  15. Review of the potential for utilizing washery refuse in N. S. W. and Queensland

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, K M

    1977-06-01

    The growing importance attached to the environment, coupled with the increasing quantities of coal refuse resulting from expanded coal production has highlighted the problem of coal refuse disposal and provided the necessary impetus to find uses for the by-product, which will eventually be regarded as a fuel and engineering material rather than a waste. Potential areas of use will be as a fuel; as a potential fuel replacement and raw material additive for brick manufacture; as a raw material for lightweight aggregate manufacture; as a construction material; for agricultural purposes, or a number of other areas of special use. The successful marketing of coal refuse will depend on an in-depth technical market analysis being carried out, followed by practical research and a comprehensive product examination and identification program being undertaken.

  16. Fundamental aspects of municipal refuse generated in Beirut and Tripoli: field studies 1994-1996

    International Nuclear Information System (INIS)

    Ayoub, G.M.; Acra, A.; Abdallah, R.; Merhebi, F.

    1996-01-01

    This study presents socio-economic survey on collection and analysis of data pertaining to the municipal refuse generated in Beirut and Tripoli, Two big cities of Lebanon.Although the collection process applied in Beirut has progressed immensely in the past two years, the unsatisfactory methods of disposal that have been employed until now has an impact on the environment:marine environment as well as the air pollution becoming problems in the city of Beirut. In this respect, solid wastes characterization and generation rates in both cities of Beirut and Tripoli are presented. Mapping of refuse collection and disposal services in the two cities is described. Sources of refuse like hospitals, industries, household,...are enumerated. Recycling potentials of plastics, paper and cardboard, glass wastes, metallic wastes, textile wastes are described

  17. Manual for best practice for emergency response procedures, part 3: a review of the department of Minerals and Energy guidelines relevant to inrushes, fires, explosions and other emergencies.

    CSIR Research Space (South Africa)

    Spencer, KC

    2000-02-01

    Full Text Available The relevant guidelines issued by the Department of Minerals and Energy were reviewed in light of the findings given in parts one and two of this report. The earlier guidelines were issued unilaterally by the Department of Minerals and Energy...

  18. Quantitative data on the fire behavior of combustible materials found in nuclear power plants: A literature review

    International Nuclear Information System (INIS)

    Nowlen, S.P.

    1987-02-01

    This report presents the findings of a task in which currently available fire research literature was reviewed for quantitative data on the burning characteristics of combustible materials that are found in nuclear power plants. The materials considered for which quantitative data were available include cable insulation materials, flammable liquids, furniture, trash and general refuse, and wood and wood products. A total of 90 figures and tables, taken primarily from the referenced works, which summarize the available quantitative fire characterization information for these materials is presented

  19. Modern tools to evaluate and optimize fire protection systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Hasegawa, H.K.

    1980-01-01

    Modern techniques, such as fault tree analysis, can be used to obtain engineering descriptions of specific fire protection systems. The analysis allows establishment of an optimum level of fire protection, and evaluates the level of protection provided by various systems. A prime example: the application to fusion energy experiments

  20. Energy

    International Nuclear Information System (INIS)

    Meister, F.; Ott, F.

    2002-01-01

    This chapter gives an overview of the current energy economy in Austria. The Austrian political aims of sustainable development and climate protection imply a reorientation of the Austrian energy policy as a whole. Energy consumption trends (1993-1998), final energy consumption by energy carrier (indexed data 1993-1999), comparative analysis of useful energy demand (1993 and 1999) and final energy consumption of renewable energy sources by sector (1996-1999) in Austria are given. The necessary measures to be taken in order to reduce the energy demand and increased the use of renewable energy are briefly mentioned. Figs. 5. (nevyjel)

  1. Improvement of environmentally relevant qualities of slags from waste-to-energy plants; Verbesserung der umweltrelevanten Qualitaeten von Schlacken aus Abfallverbrennungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Alwast, Holger [Prognos AG, Berlin (Germany); Riemann, Axel [RSP GmbH, Herne (Germany)

    2010-10-15

    This expert opinion describes options for improving slag quality (further measures for processing slag, as well as improvements of grate firing in terms of firing-technology), to ensure a slag recovery that is as sustainable as possible. In the context of this project, the term ''slag'' serves as a synonym for solid incineration residues that are generated during the incineration of wastes or of refuse derived fuels and that are separated there (e.g. from the deslagger). The term ''slags'' is also used as a synonym for grate ashes. The main focus of this expertise is on resource and climate protection issues with respect to slag processing. Resource protection refers to the saving of resources and natural raw materials, such as, for example, water and metal ores. Climate protection in this context means CO{sub 2} mitigation through a high specific net energy generation in waste incineration plants, as well as a reduced energy use due to avoided new production of metals, which can be recycled from slag processing. The main measure for improving climate and resource protection in slag processing consists therefore of separating as much metal as possible from slags. By recycling those separated slags, the energy that is needed for the extraction from ores and the raw material ore itself can be saved. This advantage in terms of energy, however, can be partially compensated by the energy use potentially needed for the improvement of slag processing. Further important aspects include the protection of water and soils, as well as the suitability of processed slag for an adequate recovery. These last criteria, however, are not central for this expertise. Currently, 69 municipal solid waste incinerators, hereinafter referred to as Waste-to-Energy (WTE) plants, and 23 refuse derived fuel (RDF) power plants with grate firing are in operation in Germany. Their total capacity amounts to more than 21 million Mg per year. Another 13 RDF

  2. The impacts of coal refuse/fly ash bulk bends on water quality and plant growth

    Energy Technology Data Exchange (ETDEWEB)

    Stewar, B.R.; Daniels, W.L. [Virginia Polytechnic Institute and State Univ., Blacksburg, VA (United States)

    1995-09-01

    There is considerable interest in the beneficial reuse of coal fly ash as a soil amendment on coal refuse piles. One method of application would be to blend the coal refuse and the fly ash before deposition in a refuse pile. A field experiment was initiated to measure the effects of bulk blending fly ash with coal refuse on water quality and plant growth parameters. Fly ash (class F) from three sources were used in the experiment. Two of the fly ashes were acidic and the third was alkaline. Trenches were excavated in a coal refuse pile to a depth of 2 m and the refuse was blended with fly ash and then returned to the trench. In other plots the ash was applied as a surface amendment. A treatment of a bulk blend of 5% (w/w) rock phosphate was also included in the experiment. Large volume lysimeters were installed in some trenches to collect the leachates. The fly ash treatments appear to improve the quality of the leachates when compared to the leachates from the untreated plots. The fly ash amended treatments have lower leachate concentrations of Fe and Al. Initially the fly ash treatments showed high levels of leachate B, however those levels have decreased with time. Millet (Setaria italica) yields from the first year of the experiment were highest n the alkaline fly ash and rock phosphate blended plots. In the second growing season, the two bulk blends with alkaline fly ash had the highest yields. In the third growing season all treatments had higher yield levels than the untreated control plots. The positive effects of the fly ash on leachate quality were attributed to the alkalinity of the ash, and the increase in yield was attributed to the increases in water holding capacity due to fly ash treatments.

  3. The Impact of Age and Sex on the Refusal Strategies Used by Iranian EFL Learners

    Directory of Open Access Journals (Sweden)

    Shohreh Shahpouri Arani

    2013-05-01

    Full Text Available One major problem for non-native speakers is using refusals and because of this, second language teachers and others who communicate in that language should have the cultural differences in mind. When the interlocutors say “no” to a request or invitation, either directly or indirectly, they use speech act of refusalRefusal is considered a face threatening act, as there exists a kind of contradiction in it and is always realized indirectly. Thus, a high level of pragmatic competence is needed to realize it. The aim of this study is to find out whether the age and sex of Iranian learners have any effect on their used refusal strategies and if the existence of such an effect was demonstrated which group is more native like in terms of content and form of used strategies. To achieve this end, graduated students (male/female of different age, sex and different fields of study were selected. Three groups of participants participated in this study. The first group includes 30 American English Speakers (A.E.S. The second group consists of participants whose ages were between 22-29 and the third group was a group of 30 participants of both sexes who speak English as a second language (sex is the only variable under study in this group. Using a Discourse Completion Test (DCT, a number of refusal situations were collected, responded by participants and analyzed. The results revealed that the age and sex of EFL learners does not have any significant effect on using refusal strategies.

  4. Why do some women refuse to allow male residents to perform pelvic exams?

    Science.gov (United States)

    Rifkin, Julie I; Shapiro, Howard; Regensteiner, Judith G; Stotler, Jeanne K; Schmidt, Betty

    2002-10-01

    Many women who receive medical care in residency training clinics refuse to allow male residents to perform their pelvic exams. This study was conducted to identify which women were most likely to refuse and to learn their reasons for refusing. From January to March 1997, a questionnaire was given to all women entering a Tri-County Health office and a Planned Parenthood clinic, both in the Denver, Colorado, metropolitan area, who consented to participate in the study. Data from the questionnaire were analyzed using a statistical software package. A total of 1,437 women entered the clinics during the study period. Of these patients, 1,078 consented to complete the questionnaire. Seven of these 1,078 women did not complete the questionnaire. Women who did not know the training level of the resident performing the pelvic exam were more likely to refuse than were women who knew the training level of the resident (p =.001), but many women preferred a female physician regardless of the physician's training level. Fifty-eight percent said they would allow a male resident to observe a female attending physician perform the exam, compared with 36% who said they would allow a male resident to observe if the attending physician was a man. Common statements from those who would refuse were: "I am just more comfortable with a female," "Women do not want men to examine their private body parts," and "Women explain things better." A woman's knowledge of the resident's training level correlates with her willingness to have a pelvic exam performed by a male resident. Women who said they would refuse a pelvic exam performed by a male resident gave specific reasons for their decision.

  5. The fire brigade renovates

    CERN Multimedia

    2002-01-01

    The new fire engine at CERN's Fire Station. A shiny brand-new fire engine is now attracting all the attention of the members of CERN's fire brigade. Since the beginning of last week this engine has taken over from an 18-year-old one, which has now been 'retired' from service. This modern vehicle, built in Brescia, Italy, is much lighter and more powerful than the old one and is equipped to allow the fire service to tackle most call-outs without the support of at least one other vehicle, as is currently necessary. The new fire engine is designed to transport six fire-fighters, 2000 litres of water, and is equipped not only for fire fighting actions but also to respond initially to any other kind of call-out, such as traffic accidents, chemical incidents, pollution, lightning, etc. It goes almost without saying that it is provided with the most modern safety measures, a low centre of gravity, as well as a special chassis and a combination pump (low and high pressure), which improve the safety and performance ...

  6. Fire exposed aluminium structures

    NARCIS (Netherlands)

    Maljaars, J.; Fellinger, J.E.J.; Soetens, F.

    2005-01-01

    Material properties and mechanical response models for fire design of steel structures are based on extensive research and experience. Contrarily, the behaviour of aluminium load bearing structures exposed to fire is relatively unexplored. This article gives an overview of physical and mechanical

  7. Advanced fire information system

    CSIR Research Space (South Africa)

    Frost, PE

    2007-01-01

    Full Text Available The South African Advanced Fire Information System (AFIS) is the first near real-time satellite-based fire monitoring system in Africa. It was originally developed for, and funded by, the electrical power utility Eskom, to reduce the impact of wild...

  8. Hot fire, cool soil

    NARCIS (Netherlands)

    Stoof, C.R.; Moore, D.; Fernandes, P.; Stoorvogel, J.J.; Fernandes, R.; Ferreira, A.J.D.; Ritsema, C.J.

    2013-01-01

    Wildfires greatly increase a landscape's vulnerability to flooding and erosion events by removing vegetation and changing soils. Fire damage to soil increases with increasing soil temperature, and, for fires where smoldering combustion is absent, the current understanding is that soil temperatures

  9. Pediatric Depression: When Does Parental Refusal for Treatment Constitute Medical Neglect?

    Science.gov (United States)

    Shapiro, Michael

    2018-06-01

    Depression is a common disorder in youth, and 10% to 15% of individuals have a lifetime prevalence by 18 years of age. Youth who receive treatment typically have a positive outcome, but many remain undiagnosed and untreated. 1 There is a dearth of literature on parental refusal to consent to treatment for pediatric depression and the circumstances under which such refusal could be considered medical neglect. In general, it appears that mental health diagnoses are rarely reported in cases of medical neglect. 2 . Copyright © 2018 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  10. [Remaining a caregiver in the face of a refusal of nursing care].

    Science.gov (United States)

    Blanchard, Karine; Ménard, Rachel; Corvol, Aline

    2016-10-01

    Caregivers working with elderly people often find themselves in a difficult position when faced with the refusal of nursing care, whether or not the patient presents cognitive disorders. The nurses from the mobile geriatrics team of Rennes university hospital are regularly asked to help the caregiving teams in such situations. Refusals may concern washing, medication, eating, moving to an armchair, the organisation of physical aids or human assistance after discharge or transfer to a nursing home. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Energy

    International Nuclear Information System (INIS)

    Meister, F.

    2001-01-01

    This chapter of the environmental control report deals with the environmental impact of energy production, energy conversion, atomic energy and renewable energy. The development of the energy consumption in Austria for the years 1993 to 1999 is given for the different energy types. The development of the use of renewable energy sources in Austria is given, different domestic heat-systems are compared, life cycles and environmental balance are outlined. (a.n.)

  12. A hydroclimatic model of global fire patterns

    Science.gov (United States)

    Boer, Matthias

    2015-04-01

    Satellite-based earth observation is providing an increasingly accurate picture of global fire patterns. The highest fire activity is observed in seasonally dry (sub-)tropical environments of South America, Africa and Australia, but fires occur with varying frequency, intensity and seasonality in almost all biomes on Earth. The particular combination of these fire characteristics, or fire regime, is known to emerge from the combined influences of climate, vegetation, terrain and land use, but has so far proven difficult to reproduce by global models. Uncertainty about the biophysical drivers and constraints that underlie current global fire patterns is propagated in model predictions of how ecosystems, fire regimes and biogeochemical cycles may respond to projected future climates. Here, I present a hydroclimatic model of global fire patterns that predicts the mean annual burned area fraction (F) of 0.25° x 0.25° grid cells as a function of the climatic water balance. Following Bradstock's four-switch model, long-term fire activity levels were assumed to be controlled by fuel productivity rates and the likelihood that the extant fuel is dry enough to burn. The frequency of ignitions and favourable fire weather were assumed to be non-limiting at long time scales. Fundamentally, fuel productivity and fuel dryness are a function of the local water and energy budgets available for the production and desiccation of plant biomass. The climatic water balance summarizes the simultaneous availability of biologically usable energy and water at a site, and may therefore be expected to explain a significant proportion of global variation in F. To capture the effect of the climatic water balance on fire activity I focused on the upper quantiles of F, i.e. the maximum level of fire activity for a given climatic water balance. Analysing GFED4 data for annual burned area together with gridded climate data, I found that nearly 80% of the global variation in the 0.99 quantile of F

  13. A Review of Fire Interactions and Mass Fires

    Directory of Open Access Journals (Sweden)

    Mark A. Finney

    2011-01-01

    Full Text Available The character of a wildland fire can change dramatically in the presence of another nearby fire. Understanding and predicting the changes in behavior due to fire-fire interactions cannot only be life-saving to those on the ground, but also be used to better control a prescribed fire to meet objectives. In discontinuous fuel types, such interactions may elicit fire spread where none otherwise existed. Fire-fire interactions occur naturally when spot fires start ahead of the main fire and when separate fire events converge in one location. Interactions can be created intentionally during prescribed fires by using spatial ignition patterns. Mass fires are among the most extreme examples of interactive behavior. This paper presents a review of the detailed effects of fire-fire interaction in terms of merging or coalescence criteria, burning rates, flame dimensions, flame temperature, indraft velocity, pulsation, and convection column dynamics. Though relevant in many situations, these changes in fire behavior have yet to be included in any operational-fire models or decision support systems.

  14. NEDO Forum 2001. Session on development of energy and environmental technologies (For promotion of comprehensive development of hydrocarbon-based energy); NEDO Forum 2001. Energy kankyo gijutsu kaihatsu session (tanka suisokei energy no sogo kaihatsu suishin no tame ni)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-20

    The presentations made at the above-named session of the NEDO (New Energy and Industrial Technology Development Organization) forum held in Tokyo on September 20, 2001, are collected in this report. Pointed out in a lecture entitled 'How technology development for hydrocarbon-based energy resources should be' was the need of technologies for clean energy production; CO2 emission reduction; NOx, SOx, soot, and dust reduction; and the expansion of exploitation of resources now left unused. Reported in a lecture entitled 'Cooperation with China on coal liquefaction' were the result of a coal liquefaction demonstration plant feasibility study conducted for coal from Inner Mongolia, and so forth. Reported in a lecture entitled 'Development of coal oil upgrading technology' were the result of the operation of a test plant, and so forth. Reported in a lecture entitled 'Research and development of HyperCoal' were the result of HyperCoal manufacturing technology research and development, designing of a HyperCoal-fired gas turbine power generation system, and so forth. In addition, development of technology for high efficiency conversion of biomass energy and development of technology for refuse gasification/melting power generation were reported. (NEDO)

  15. Surface Fire Hazards Analysis Technical Report-Constructor Facilities

    International Nuclear Information System (INIS)

    Flye, R.E.

    2000-01-01

    The purpose of this Fire Hazards Analysis Technical Report (hereinafter referred to as Technical Report) is to assess the risk from fire within individual fire areas to ascertain whether the U.S. Department of Energy (DOE) fire safety objectives are met. The objectives identified in DOE Order 420.1, Change 2, Facility Safety, Section 4.2, establish requirements for a comprehensive fire and related hazards protection program for facilities sufficient to minimize the potential for: The occurrence of a fire or related event; A fire that causes an unacceptable on-site or off-site release of hazardous or radiological material that will threaten the health and safety of employees, the public, or the environment; Vital DOE programs suffering unacceptable interruptions as a result of fire and related hazards; Property losses from a fire and related events exceeding defined limits established by DOE; and Critical process controls and safety class systems being damaged as a result of a fire and related events

  16. Fires in Chile

    Science.gov (United States)

    2002-01-01

    On February 5, 2002, the dense smoke from numerous forest fires stretched out over the Pacific Ocean about 400 miles south of Santiago, Chile. This true-color Moderate-resolution Imaging Spectroradiometer (MODIS) image shows the fires, which are located near the city of Temuco. The fires are indicated with red dots (boxes in the high-resolution imagery). The fires were burning near several national parks and nature reserves in an area of the Chilean Andes where tourism is very popular. Southeast of the fires, the vegetation along the banks of the Rio Negro in Argentina stands out in dark green. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC

  17. Sodium fire protection

    International Nuclear Information System (INIS)

    Raju, C.; Kale, R.D.

    1979-01-01

    Results of experiments carried out with sodium fires to develop extinguishment techniques are presented. Characteristics, ignition temperature, heat evolution and other aspects of sodium fires are described. Out of the powders tested for extinguishment of 10 Kg sodium fires, sodium bi-carbonate based dry chemical powder has been found to be the best extinguisher followed by large sized vermiculite and then calcium carbonate powders distributed by spray nozzles. Powders, however, do not extinguish large fires effectively due to sodium-concrete reaction. To control large scale fires in a LMFBR, collection trays with protective cover have been found to cause oxygen starvation better than flooding with inert gas. This system has an added advantage in that there is no damage to the sodium facilities as has been in the case of powders which often contain chlorine compounds and cause stress corrosion cracking. (M.G.B.)

  18. Market forces in municipal and industrial waste-to-energy

    International Nuclear Information System (INIS)

    Makansi, J.

    1991-01-01

    The market for municipal and industrial waste-to-energy can be characterized simply as currently soft with continued excellent long-term prospects. But as in all markets large and small, niche opportunities exist now which can be profitable with proper definition and strategy. Economics of several projects have proven marginal, cost overruns are common, and revenue projections are sometimes overstates. Also contributing to poorer economics of late are lower prices for the electric power produced from these plants. New environmental restrictions are adding 10-15% to the capital costs of a given project. On the industrial front, the strength of waste-fuel firing continues to be evident for independent power production. Important fuel-niche markets have sprung up over the last decade including petroleum coke, coal-mining wastes, hospital or redbag wastes, biomass, used tires, and so on. Another fuel niche is hazardous waste incineration. In the municipal arena, realism has not yet hit the recycling and source reduction enthusiasts. Only 25-35% recycling is considered practical by experts. There are also limits to how often material can be recycled. Finally, in spite of the best efforts of the population to control the amount of refuse generated and to recycle that which is, population and economic growth may overtake any new sense of environmental responsibility. And, yes, the additional refuse still has to go somewhere exclamation point The best somewhere option continues to be a waste-to-energy plant. Current market opportunities and two other market forces (international activities and the role of US utilities) are discussed

  19. Energy from waste. Vol. 2; Energie aus Abfall. Bd. 2

    Energy Technology Data Exchange (ETDEWEB)

    Thome-Kozmiensky, K.J.; Beckmann, M.

    2007-07-01

    In the book under consideration, the thermal treatment in waste incinerators, in industrial power stations and in coal-fired power stations is in the foreground. Possibilities of gasification are described. The chapter 'Developments of thermal waste treatment' consists of the following chapter: (a) Maximal size of waste incineration plants (Johannes J.E. Martin); (b) Trends and highlights of the thermal waste treatment in Europe (Martin Brunner); (c) Utilization of waste heat from Vienna waste incinerators for the operation of a district cooling grid - Effects on the primary energy efficiency of district heating and district cooling in Vienna (Franz Schindelar, Alexander Wallisch); (d) Evolutionary plant development based on experiences (Hans-Peter Buechner); (e) Effects of increased chlorine freights at the cocombustion of secondary fuels at the site of the brown coal fired power station Jaenschwalde (Frank Mielke, Andreas Sparmann, Sven Kappa); (f) Refuse-fueled power stations and waste incinerators - different plant technology? (Hendrik Seeger); (g) Generation of fuel gas from high calorific wastes (Udo Hellwig, Michael Beyer); (h) Strength testing of steam vessels with increased testing pressure (Wolfgang Rossmaier). The chapter 'Energy efficiency of waste incinerators' consists the following contributions: (a) Evaluation of energy efficiency in plants of thermal waste treatment; (b) Scientific-technical and juridical rationality - a contradiction? Comments to the judgement o the VGH Baden-Wuerttemberg according to waste incineration (Bodo A. Baars and Adolf Nottrodt); (c) Determination of the energy efficiency in plants of thermal waste incineration - To the difficulties of equivalent values and calculation of the calorific value (Michael Beckmann, Reinhard Scholz). The chapter 'Optimization of the plant technology' contains the following contributions: (a) Stay a while - Considerations according to the first tank of thermal waste

  20. USFA NFIRS 2005 Basic Fire Incident Data

    Data.gov (United States)

    Department of Homeland Security — The 2005 US Fire Administration Fire (USFA) Fire Incident & Cause Data was provided by the U.S. Fire Administration's (USFA) National Fire Data Center's (NFDC's)...