WorldWideScience

Sample records for refrigeration capacity management

  1. Refrigerator with variable capacity compressor and cycle priming action through capacity control and associated methods

    Science.gov (United States)

    Gomes, Alberto Regio; Litch, Andrew D.; Wu, Guolian

    2016-03-15

    A refrigerator appliance (and associated method) that includes a condenser, evaporator and a multi-capacity compressor. The appliance also includes a pressure reducing device arranged within an evaporator-condenser refrigerant circuit, and a valve system for directing or restricting refrigerant flow through the device. The appliance further includes a controller for operating the compressor upon the initiation of a compressor ON-cycle at a priming capacity above a nominal capacity for a predetermined or calculated duration.

  2. Nonlinear superheat and capacity control of a refrigeration plant

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Larsen, Lars F. S.

    2009-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. A new low order nonlinear model of the evaporator is developed and used in a backstepping design of a nonlinear controller. The stability of the proposed method is validated theoretically by Lyapunov...

  3. Refrigerating liquid prototype for LED's thermal management

    International Nuclear Information System (INIS)

    Faranda, Roberto; Guzzetti, Stefania; Lazaroiu, George Cristian; Leva, Sonia

    2012-01-01

    The heat management is the critical factor for high performance operation of LED. A new heat management application of refrigerating liquid integrated within a fabricated prototype is proposed and investigated. A series of experiments considering different heights of liquid level were performed to evaluate the heat dissipation performance and optical characteristics of the refrigerating liquid based prototype. The results reveal that the junction temperature decreases as the level of refrigerating liquid increases. The experimental results report that the refrigerating liquid reduces the junction temperature, and can positively influence the luminous radiation performances. An optimization investigation of the proposed solution was carried out to find an optimum thermal performance. The experiments indicated that refrigerating liquid cooling is a powerful way for heat dissipation of high power LEDs, and the fabrication of prototype was feasible and useful. - Highlights: ► New heat management application of refrigerating liquid on a fabricated LED prototype. ► Thermal models setup and comparison between the classical and the new solutions. ► The impact of refrigerating liquid level on LED thermal and luminous performances. ► The relationship between different levels of liquid with LED prototype performances.

  4. Refrigerant charge management in a heat pump water heater

    Science.gov (United States)

    Chen, Jie; Hampton, Justin W.

    2014-06-24

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

  5. Dynamic simulation of variable capacity refrigeration systems under abnormal conditions

    International Nuclear Information System (INIS)

    Liang Nan; Shao Shuangquan; Tian Changqing; Yan Yuying

    2010-01-01

    There are often abnormal working conditions at evaporator outlet of a refrigeration system, such as two-phase state in transient process, and it is essential to investigate such transient behaviours for system design and control strategy. In this paper, a dynamic lumped parameter model is developed to simulate the transient behaviours of refrigeration system with variable capacity in both normal and abnormal working conditions. The appropriate discriminant method is adopted to switch the normal and abnormal conditions smoothly and to eliminate the simulated data oscillation. In order to verify the dynamic model, we built a test system with variable frequency compressor, water-cooling condenser, evaporator and electronic expansion valve. Calculated values from the mathematical model show reasonable agreement with the experimental data. The simulation results show that the transient behaviours of the variable capacity refrigeration system in the abnormal working conditions can be calculated reliably with the dynamic model when the compressor rotary speed or the opening of electronic expansion valve changes abruptly.

  6. Monte Carlo approach to define the refrigerator capacities for JT-60SA

    International Nuclear Information System (INIS)

    Wanner, Manfred; Barabaschi, Pietro; Lamaison, Valerie; Michel, Frederic; Reynaud, Pascal; Roussel, Pascal

    2011-01-01

    The JT-60SA cryogenic system shall provide refrigeration to keep the superconducting magnets and their structures at 4.4 K, cryo-pumps at 3.7 K, thermal shields at 80-100 K, and deliver a flow of 50 K helium to the current leads. A Monte Carlo method is proposed to determine the capacity contingencies for the refrigeration system. Attributing individual contingencies and distribution probability functions to the design variables allows the different load contributions to be statistically averaged. The total refrigeration contingency is derived for each temperature level from the 95% confidence level of the integrated distribution function.

  7. Load management for refrigeration systems: Potentials and barriers

    Energy Technology Data Exchange (ETDEWEB)

    Grein, Arne, E-mail: a.grein@tu-berlin.de [University of Technology Berlin, Institute for Energy Technology, Department of Energy Systems, Einsteinufer 25 (TA8), 10587 Berlin (Germany); Pehnt, Martin [Institute for Energy and Environmental Research Heidelberg (ifeu), Wilckensstr. 3, 69120 Heidelberg (Germany)

    2011-09-15

    As a strategy to deal with the increasing intermittent input of renewable energy sources in Germany, the adaptation of power consumption is complementary to power-plant regulation, grid expansion and physical energy storage. One demand sector that promises strong returns for load management efforts is cooling and refrigeration. In these processes, thermal inertia provides a temporal buffer for shifting and adjusting the power consumption of cooling systems. We have conducted an empirical investigation to obtain a detailed and time-resolved bottom-up analysis of load management for refrigeration systems in the city of Mannheim, Germany. We have extrapolated our results to general conditions in Germany. Several barriers inhibit the rapid adoption of load management strategies for cooling systems, including informational barriers, strict compliance with legal cooling requirements, liability issues, lack of technical experience, an inadequate rate of return and organizational barriers. Small commercial applications of refrigeration in the food-retailing and cold storage in hotels and restaurants are particularly promising starting points for intelligent load management. When our results are applied to Germany, suitable sectors for load management have theoretical and achievable potential values of 4.2 and 2.8 GW, respectively, amounting to about 4-6% of the maximum power demand in Germany. - Highlights: > Potential and barriers for implementation of load shifting for refrigeration. > Empirical investigation for time-resolved bottom-up analysis in Mannheim, Germany. > Suitable sectors and further recommendations for introducing load management.> Extrapolation of results from local to national level.

  8. Magnetic hysteresis and refrigeration capacity of Ni–Mn–Ga alloys near Martensitic transformation

    International Nuclear Information System (INIS)

    Bin, Fu; Yi, Long; Jing-Fang, Duan; Chao-Lun, Wang; Yong-Qin, Chang; Rong-Chang, Ye; Guang-Heng, Wu

    2010-01-01

    This paper studies the magnetic hysteresis and refrigeration capacity of Ni-Mn-Ga alloys in detail during heating and cooling isothermal magnetisation processes. The Ni-Mn-Ga alloys show larger magnetic hysteresis when they transform from austenite to martensite, but smaller magnetic hysteresis when they transform from martensite to austenite. This behaviour is independent of either the pure Ni-Mn-Ga alloys or the alloys doped with other elements. Because of the existence of the magnetic hysteresis, the relation between the magnetic entropy change and refrigeration capacity is not simply linear. For practical consideration, magnetocaloric effect of Ni-Mn-Ga alloys should be investigated both on cooling and heating processes. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  9. Load management for refrigeration systems: Potentials and barriers

    International Nuclear Information System (INIS)

    Grein, Arne; Pehnt, Martin

    2011-01-01

    As a strategy to deal with the increasing intermittent input of renewable energy sources in Germany, the adaptation of power consumption is complementary to power-plant regulation, grid expansion and physical energy storage. One demand sector that promises strong returns for load management efforts is cooling and refrigeration. In these processes, thermal inertia provides a temporal buffer for shifting and adjusting the power consumption of cooling systems. We have conducted an empirical investigation to obtain a detailed and time-resolved bottom-up analysis of load management for refrigeration systems in the city of Mannheim, Germany. We have extrapolated our results to general conditions in Germany. Several barriers inhibit the rapid adoption of load management strategies for cooling systems, including informational barriers, strict compliance with legal cooling requirements, liability issues, lack of technical experience, an inadequate rate of return and organizational barriers. Small commercial applications of refrigeration in the food-retailing and cold storage in hotels and restaurants are particularly promising starting points for intelligent load management. When our results are applied to Germany, suitable sectors for load management have theoretical and achievable potential values of 4.2 and 2.8 GW, respectively, amounting to about 4-6% of the maximum power demand in Germany. - Highlights: → Potential and barriers for implementation of load shifting for refrigeration. → Empirical investigation for time-resolved bottom-up analysis in Mannheim, Germany. → Suitable sectors and further recommendations for introducing load management.→ Extrapolation of results from local to national level.

  10. Capacity planning and management

    OpenAIRE

    Boydell, Briony

    2011-01-01

    After reading this chapter you should be able to: • Define and measure capacity and appreciate the factors that influence it. • Assess the difficulties of matching capacity to demand. • Evaluate and apply the different strategies for matching capacity with demand in the short, medium and long term. • Analyse the impact of constraints and bottlenecks on a process and consider the Theory of Constraints. • Outline the different strategies available for both manufacturing and service operations. ...

  11. Enhanced refrigerant capacity in Gd-Al-Co microwires with a biphase nanocrystalline/amorphous structure

    Energy Technology Data Exchange (ETDEWEB)

    Shen, H. X. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Department of Physics, University of South Florida, Tampa, Florida 33620 (United States); Xing, D. W.; Liu, Y. F.; Sun, J. F. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Sánchez Llamazares, J. L. [Instituto Potosino de Investigación Científica y Tecnológica A.C., Camino a la Presa San José 2055 Col. Lomas 4a, San Luis Potosí, S.L.P. 78216 (Mexico); Sánchez-Valdés, C. F. [Centro de Nanociencias y Nanotecnología, Universidad Nacional Autónoma de México, AP 14, Ensenada 22860, Baja California (Mexico); Belliveau, H.; Srikanth, H.; Phan, M. H., E-mail: phanm@usf.edu [Department of Physics, University of South Florida, Tampa, Florida 33620 (United States); Wang, H.; Qin, F. X. [Institute for Composites Science and Innovation (InCSI), College of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China)

    2016-02-29

    A class of biphase nanocrystalline/amorphous Gd{sub (50+5x)}Al{sub (30−5x)}Co{sub 20} (x = 0, 1, 2) microwires fabricated directly by melt-extraction is reported. High resolution transmission electron microscopy and Fourier function transform based analysis indicate the presence of a volume fraction (∼20%) of ∼10 nm sized nanocrystallities uniformly embedded in an amorphous matrix. The microwires possess excellent magnetocaloric properties, with large values of the isothermal entropy change (−ΔS{sub M} ∼ 9.7 J kg{sup −1} K{sup −1}), the adiabatic temperature change (ΔT{sub ad} ∼ 5.2 K), and the refrigerant capacity (RC ∼ 654 J kg{sup −1}) for a field change of 5 T. The addition of Gd significantly alters T{sub C} while preserving large values of the ΔS{sub M} and RC. The nanocrystallites allow for enhanced RC as well as a broader operating temperature span of a magnetic bed for energy-efficient magnetic refrigeration.

  12. Modeling Supermarket Refrigeration Systems for Demand-Side Management

    Directory of Open Access Journals (Sweden)

    Jakob Stoustrup

    2013-02-01

    Full Text Available Modeling of supermarket refrigeration systems for supervisory control in the smart grid is presented in this paper. A modular modeling approach is proposed in which each module is modeled and identified separately. The focus of the work is on estimating the power consumption of the system while estimating the cold reservoir temperatures as well. The models developed for each module as well as for the overall integrated system are validated by real data collected from a supermarket in Denmark. The results show that the model is able to estimate the actual electrical power consumption with a high fidelity. Moreover a simulation benchmark is introduced based on the produced model for demand-side management in smart grid. Finally, a potential application of the proposed benchmark in direct control of the power/energy consumption is presented by a simple simulation example.

  13. Hydrophilic structures for condensation management in refrigerator appliances

    Science.gov (United States)

    Kuehl, Steven John; Vonderhaar, John J; Wu, Guolian; Wu, Mianxue

    2014-10-21

    A refrigerator appliance that includes a freezer compartment having a freezer compartment door, and a refrigeration compartment having at least one refrigeration compartment door. The appliance further includes a mullion with an exterior surface. The mullion divides the compartments and the exterior surface directs condensation toward a transfer point. The appliance may also include a cabinet that houses the compartments and has two sides, each with an exterior surface. Further, at least one exterior surface directs condensation toward a transfer point.

  14. Control Methods for Energy Management of Refrigeration Systems

    DEFF Research Database (Denmark)

    Shafiei, Seyed Ehsan

    is decreased as the method does not need an explicit model of the system and, at the same time, the desired load following performance is attained. Recent research findings indicate that the refrigeration system commonly employed in food transportation can account for 40% of the total greenhouse gas emissions...... from the corresponding vehicle engines. Finally, the problem of optimization of a hybrid transport refrigeration system is addressed here. The hybrid refrigeration system is made by the integration of conventional refrigeration technology with thermal energy storage devices....

  15. Capacity Planning and Leadtime management

    NARCIS (Netherlands)

    Zijm, Willem H.M.; Buitenhek, R.

    1996-01-01

    In this paper we discuss a framework for capacity planning and lead time management in manufacturing companies, with an emphasis on the machine shop. First we show how queueing models can be used to find approximations of the mean and the variance of manufacturing shop lead times. These quantities

  16. Capacity Building in Land Management

    DEFF Research Database (Denmark)

    Enemark, Stig; Ahene, Rexford

    2003-01-01

    There is a significant need for capacity building in the interdisciplinary area of land management especially in developing countries and countries in transition, to deal with the complex issues of building efficient land information systems and sustainable institutional infrastructures. Capacity...... building in land management is not only a question of establishing a sufficient technological level or sufficient economic resources. It is mainly a question of understanding the interdisciplinary and cross-sectoral nature of land administration systems, and understanding the need for human resource...... and professionals for implementing the new land policy. The curriculum combines the diploma and the bachelor level and it combines the key areas of land surveying, land management and physical planning....

  17. Integrated flexible capacity and inventory management under flexible capacity uncertainty

    OpenAIRE

    Paç, Mehmet Fazıl

    2006-01-01

    Cataloged from PDF version of article. In a manufacturing environment with volatile demand, inventory management can be coupled with dynamic capacity adjustments for handling the fluctuations more effectively. In this study we consider the integrated management of inventory and flexible capacity management under seasonal stochastic demand and uncertain labor supply. The capacity planning problem is investigated from the workforce planning perspective. We consider a manufactu...

  18. Research of thermal dynamic characteristics for variable load single screw refrigeration compressor with different capacity control mechanism

    International Nuclear Information System (INIS)

    Wang, Zengli; Wang, Zhenbo; Wang, Jun; Jiang, Wenchun; Feng, Quanke

    2017-01-01

    Highlights: • Theoretical models of SSRC under part-load condition have been established. • The experiment of SSRC performance under part-load condition was conducted. • Thermal dynamic characteristic of SSRC under part-load condition was gained. • Economy and reliability of SSRC under part-load condition was analyzed. - Abstract: In the single screw refrigeration compressor (SSRC), the capacity control mechanism is normally employed to meet the actual required cooling capacity under different load conditions. In this paper, theoretical calculation models describing the working process of the SSRC with the single slide valve capacity control mechanism (SVCCM) and SSRC with the frequency conversion regulating mechanism (FCRM) are established to research the thermal dynamic characteristics for variable load SSRC under part-load conditions. Experimental investigation on a SSRC under part-load conditions is also carried out to verify the theoretical calculation models. By using these validated models, the thermodynamic performances and dynamic characteristics of the SSRC with different capacity control mechanism under part-load conditions have been analyzed and compared. Through the comparison, the economical efficiency and reliability of the SSRC with different capacity control mechanism were obtained. All of these works can provide the basis for the later optimization design for the variable load single screw refrigeration compressor.

  19. Modeling Supermarket Refrigeration Systems for Demand-Side Management

    DEFF Research Database (Denmark)

    Shafiei, Seyed Ehsan; Rasmussen, Henrik; Stoustrup, Jakob

    2013-01-01

    Modeling of supermarket refrigeration systems for supervisory control in the smart grid is presented in this paper. A modular modeling approach is proposed in which each module is modeled and identified separately. The focus of the work is on estimating the power consumption of the system while...

  20. Ideal gas contribution to the isobaric heat capacity of refrigerants: Poling et al.’s polynomial correlation vs DIPPR data

    International Nuclear Information System (INIS)

    Mulero, Angel; Cachadiña, Isidro; Tian, Jianxiang

    2013-01-01

    Highlights: ► The ideal gas contribution to the isobaric heat capacity of 58 refrigerants is calculated. ► Poling et al.’s polynomial correlation on temperature is used. ► Results are compared with DIPPR data and the correlation extended to higher temperatures. ► New coefficients for the correlation are given. ► Mean average percentage deviations with these new coefficients are lower than 1% for 49 refrigerants. -- Abstract: The ideal gas contribution to the isobaric heat capacity of fluids is a temperature dependent property which is commonly modelled as a polynomial expression. In this work, the performance and accuracy of the polynomial correlation proposed by Poling et al. in their well-known book is checked. To this end, the data accepted in the DIPPR database for 58 refrigerants were used. The mean average percentage deviations (MAPDs) obtained in the temperature range considered by Poling et al., usually up to 1000 K, are greater than 1.5% only for six refrigerants. We extended our study to the temperature range in which accepted DIPPR data are available (usually up to 1500 K), finding that only for four refrigerants can the Poling et al. correlation be used in this extended range. New coefficients for the correlation are given for the 58 refrigerants studied which reproduce the accepted DIPPR data. The new MAPD values are then below 1% for 49 refrigerants

  1. Managing nuclear predominant generating capacity

    International Nuclear Information System (INIS)

    Bouget, Y.H.; Carbonnier, D.

    1999-01-01

    The most common believe, associated with nuclear power plant, leads to the conclusion that it can only operate, as a base load plant. This observation can be reversed, by just looking at large generating capacity, using an important nuclear generation mix. Nuclear plants may certainly load follow and contribute to the grid frequency control. The French example illustrates these possibilities. The reactor control of French units has been customized to accommodate the grid requests. Managing such a large nuclear plant fleet requires to take various actions, ranging from a daily basis to a multi-annual prospective standpoint. The paper describes the various contributions leading to safe, reliable, well accepted and cost competitive nuclear plants in France. The combination of all aspects related to operations, maintenance scheduling, nuclear safety management, are presented. The use of PWR units carries considerable weight in economic terms, with several hundred million francs tied in with outage scheduling every year. This necessitates a global view of the entire generating system which can be mobilized to meet demand. There is considerable interaction between units as, on the one hand, they are competing to satisfy the same need, and, on the other hand, reducing maintenance costs means sharing the necessary resources, and thus a coordinated staggering of outages. In addition, nuclear fuel is an energy reserve which remains in the reactor for 3 or 4 years, with some of the fuel renewed each year. Due to the memory effect, the fuel retains a memory of past use, so that today's choices impact upon the future. A medium-term view of fuel management is also necessary. The coordination systems implemented by EDF aim to control these parameters for the benefit of electricity consumers. (author)

  2. Enhanced glass forming ability and refrigerant capacity of a Gd55Ni22Mn3Al20 bulk metallic glass

    International Nuclear Information System (INIS)

    Xia, L.; Chan, K.C.; Tang, M.B.

    2011-01-01

    Highlights: → A new Gd 55 Ni 22 Mn 3 Al 20 bulk metallic glass (BMG) was synthesized by minor Mn addition. → The BMG has enhanced glass forming ability and excellent refrigerant capacity (RC). → The RC of the BMG reaches a high value of 825 J kg -1 under a field of 3979 kA/m. → Its excellent RC is related to its large effective magnetic moment. - Abstract: In this work, a small amount of Mn was added to a Gd 55 Ni 25 Al 20 glass forming alloy, as a replacement for Ni, and a Gd 55 Ni 22 Mn 3 Al 20 bulk metallic glass (BMG) was obtained by suction casting. Its glass forming ability (GFA) was characterized by X-ray diffraction and differential scanning calorimetry, and its magnetic properties were measured using a magnetic property measurement system. It is found that the minor Mn addition can significantly improve both the GFA and the magnetocaloric effect (MCE) of the alloy. The refrigerant capacity (RC) of the BMG can reach a high value of 825 J kg -1 under a field of 3979 kA/m, which is about 29% larger than that of a Gd 55 Ni 25 Al 20 BMG. The effect of the minor Mn addition on the GFA and MCE of the BMG was investigated in the study.

  3. Very large refrigerant capacity at room temperature with reproducible magnetocaloric effect in Fe0.975Ni0.025Rh

    International Nuclear Information System (INIS)

    Manekar, Meghmalhar; Roy, S B

    2011-01-01

    We present the results of magnetocaloric effect (MCE) measurements on Fe 0.975 Ni 0.025 Rh. The MCE is estimated using both the isothermal field-dependent magnetization and the temperature-dependent magnetization in constant magnetic fields. We find a very large effective refrigerant capacity of nearly 492.8 J kg -1 , with the hot end at about 307 K, which is reproducible over many field cycles. We compare this refrigerant capacity with those of two well known systems, namely Gd 5 Ge 1.9 Si 2 Fe 0.1 and MnFeP 0.45 As 0.55 , which show a large MCE near room temperature, and also with our earlier results on the parent Fe-Rh alloy. The large effective refrigerant capacity in our sample is one of the largest achieved yet at room temperature with a significant improvement over the parent Fe-Rh system. (fast track communication)

  4. Investigation on output capacity control strategy of variable refrigerant flow air conditioning system with multi-compressor

    International Nuclear Information System (INIS)

    Tu, Qiu; Zou, Deqiu; Deng, Chenmian; Zhang, Jie; Hou, Lifeng; Yang, Min; Nong, Guicai; Feng, Yuhai

    2016-01-01

    Highlights: • The control model of compressor output capacity has been built. • The control strategy of compressor switching has been presented. • The switching process of standard compressor has been described. • The characteristics of EER and noise have been presented. • The control strategy and model have been proved by experiments. - Abstract: A set of 14 HP variable refrigerant flow air conditioning system (VRF AC) with multi-compressor has been designed, and the output capacity control strategy of compressor(s) including the switching control model of standard compressor has been built. In the output capacity control model, a certain suction pressure is used as the pressure control target to adjust the output capacity of compressors, and a little pressure fluctuation is taken into account to amend the target pressure. Furthermore, in the compressor switching control model, the most favorable operation frequency region is determined on base of the energy efficiency characteristic and noise characteristic of the compressor. And, in order to solve the large fluctuation problem of the system running and frequent ON-OFF action of the standard compressor, the equal output capacity switching principle can be used to determine the thermo-on and thermo-off switched frequency points, and control the switching process of the compressor. Experiments demonstrate the feasibility of this control strategy to ensure the stability and reliability, improve the energy efficiency and reduce the compressor noise.

  5. An optimal power management system for a regenerative auxiliary power system for delivery refrigerator trucks

    International Nuclear Information System (INIS)

    Mohagheghi Fard, Soheil; Khajepour, Amir

    2016-01-01

    Highlights: • A new anti-idling system for refrigerator trucks is proposed. • This system enables regenerative braking. • An innovative two-level controller is proposed for the power management system. • A fast dynamic programming technique to find real-time SOC trajectory is proposed. • In addition to idling elimination, this system reduces fuel consumption. - Abstract: Engine idling of refrigerator trucks during loading and unloading contributes to greenhouse gas emissions due to their increased fuel consumption. This paper proposes a new anti-idling system that uses two sources of power, battery and engine-driven generator, to run the compressor of the refrigeration system. Therefore, idling can be eliminated because the engine is turned OFF and the battery supplies auxiliary power when the vehicle is stopped for loading or unloading. This system also takes advantage of regenerative braking for increased fuel savings. The power management of this system needs to satisfy two requirements: it must minimize fuel consumption in the whole cycle and must ensure that the battery has enough energy for powering the refrigeration system when the engine is OFF. To meet these objectives, a two-level controller is proposed. In the higher level of this controller, a fast dynamic programming technique that utilizes extracted statistical features of drive and duty cycles of a refrigerator truck is used to find suboptimal values of the initial and final SOC of any two consecutive loading/unloading stops. The lower level of the controller employs an adaptive equivalent fuel consumption minimization (A-ECMS) to determine the split ratio of auxiliary power between the generator and battery for each segment with initial and final SOC obtained by the high-level controller. The simulation results confirm that this new system can eliminate idling of refrigerator trucks and reduce their fuel consumption noticeably such that the cost of replacing components is recouped in a

  6. Performance management in the internal supply chain of an industry of equipment for refrigeration

    Directory of Open Access Journals (Sweden)

    Emílio Della Bruna Junior

    2013-05-01

    Full Text Available Supply chains are complex, conflicting and uncertain management environments, where the best alternatives are usually not previously know, they need to be built based on the managers objectives. For this reason, its decision-makers have been looking for management tools that expand their understanding in order to identify which objectives best represent their values regarding the decision context. With this in mind, this paper aims to develop a Performance Evaluation Model for the operations of the internal supply chain of an organization of the refrigeration equipment sector. The study adopts a mixture of qualitative and quantitative approaches and applies them through a case study. The data collection was conducted through unstructured interviews with the decision-maker as well as specialists appointed by him and supplemented by documentary research. The applied intervention instrument is the Multricriteria Decision Aid – Constructivist (MCDA-C due to its capacity of expanding the knowledge in the decision-maker about the consequences of his decisions on the criteria that he deems critical to the success of the company. One of the results of this research was the identification of the objectives that, according to the decision-maker perception, should drive the alternative definition process, as well as their organization, ordinal and cardinal measurement and integration. In addition, it can be highlighted the current situation diagnosis and elaboration of improvement actions, where the implementation effects of the Lean Philosophy and an Advanced Planning System are evaluated. The main contributions made by the article resides in the proposal of solutions for fulfilling gaps identified within the Supply Chain Performance Evaluation area and in the application of the MCDA-C to a real case.

  7. Inventory management with advance capacity information

    NARCIS (Netherlands)

    Jaksic, M.; Fransoo, J.C.; Tan, T.; Kok, de A.G.; Rusjan, B.

    2008-01-01

    One of the important aspects of supply chain management is dealing with demand and supply uncertainty. The uncertainty of future supply can be reduced, if a company is able to obtain advance capacity information (ACI) on future supply/production capacity availability from its supplier. We address a

  8. Inventory management with advance capacity information

    NARCIS (Netherlands)

    Jaksic, M.; Fransoo, J.C.; Tan, T.; Kok, de A.G.; Rusjan, B.

    2011-01-01

    An important aspect of supply chain management is dealing with demand and supply uncertainty. The uncertainty of future supply can be reduced if a company is able to obtain advance capacity information (ACI) about future supply/production capacity availability from its supplier. We address a

  9. Adaptive Capacity Management in Bluetooth Networks

    DEFF Research Database (Denmark)

    Son, L.T.

    , such as limited wireless bandwidth operation, routing, scheduling, network control, etc. Currently Bluetooth specification particularly does not describe in details about how to implement Quality of Service and Resource Management in Bluetooth protocol stacks. These issues become significant, when the number...... of Bluetooth devices is increasing, a larger-scale ad hoc network, scatternet, is formed, as well as the booming of Internet has demanded for large bandwidth and low delay mobile access. This dissertation is to address the capacity management issues in Bluetooth networks. The main goals of the network capacity...... capacity allocation, network traffic control, inter-piconet scheduling, and buffer management. First, after a short presentation about Bluetooth technology, and QoS issues, queueing models and a simulation-based buffer management have been constructed. Then by using analysis and simulation, it shows some...

  10. Development of large-capacity refrigeration at 1.8 K for the Large Hadron Collider at CERN

    CERN Document Server

    Lebrun, P; Claudet, G

    1996-01-01

    CERN, the European Laboratory for Particle Physics, is working towards the construction of the Large Hadron Collider (LHC), a high-energy, high-luminosity particle accelerator and collider [1] of 26.7 km circumference, due to start producing frontier physics, by bringing into collision intense proton and ion beams with centre-of-mass energies in the TeV-per-constituent range, at the beginning of the next century. The key technology for achieving this ambitious scientific goal at economically acceptable cost is the use of high-field superconducting magnets using Nb-Ti conductor operating in superfluid helium [2]. To maintain the some 25 km of bending and focusing magnets at their operating temperature of 1.9 K, the LHC cryogenic system will have to produce an unprecedented total refrigeration capacity of about 20 kW at 1.8 K, in eight cryogenic plants distributed around the machine circumference [3]. This has requested the undertaking of an industrial development programme, in the form of a collaboration betwe...

  11. WORKING MEMORY CAPACITY TEST REVEALS SUBJECTS DIFFICULTIES MANAGING LIMITED CAPACITY

    Directory of Open Access Journals (Sweden)

    R V Ershova

    2016-12-01

    Full Text Available Free recall consists of two separate stages: the emptying of working memory and reactivation [5]. The Tarnow Unchunkable Test (TUT, [7] uses double integer items to separate out only the first stage by making it difficult to reactivate items due to the lack of intra-item relationships.193 Russian college students were tested via the internet version of the TUT. The average number of items remembered in the 3 item test was 2.54 items. In the 4 item test, the average number of items decreased to 2.38. This, and a number of other qualitative distribution differences between the 3 and 4 item tests, indicate that the average capacity limit of working memory has been reached at 3 items. This provides the first direct measurement of the unchunkable capacity limit of number items.Difficulties in managing working memory occurred as most subjects remembered less as the number of items increased beyond capacity and failed to remember a single item in at least one out of three 4 item trials. The Pearson correlation between the total recall of 3 and 4 items was a small 38%.

  12. Appendix E: Supplemental Risk Management Program Guidance for Ammonia Refrigeration Facilities

    Science.gov (United States)

    Additional information for food processors, food distributors, refrigerated warehouses, and any other facility that has an ammonia refrigeration system. Includes details on exemption for farms, threshold quantity, and offsite consequence analysis.

  13. Public management, policy capacity, innovation and development

    Directory of Open Access Journals (Sweden)

    Erkki Karo

    2014-03-01

    Full Text Available In this paper we discuss the question of what factors in development policy create specific forms of policy capacity and under what circumstances developmentoriented complementarities or mismatches between the public and private sectors emerge. We argue that specific forms of policy capacity emerge from three interlinked policy choices, each fundamentally evolutionary in nature: policy choices on understanding the nature and sources of technical change and innovation; on the ways of financing economic growth, in particular technical change; and on the nature of public management to deliver and implement both previous sets of policy choices. Thus, policy capacity is not so much a continuum of abilities (from less to more, but rather a variety of modes of making policy that originate from co-evolutionary processes in capitalist development. To illustrate, we briefly reflect upon how the East Asian developmental states of the 1960s-1980s and Eastern European transition policies since the 1990s led to almost opposite institutional systems for financing, designing and managing development strategies, and how this led, through co-evolutionary processes, to different forms of policy capacity.

  14. Refrigeration and global warming

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    Some aspects of global warming in general, and the implications for refrigerants and refrigerator efficiency in particular, are briefly considered in a question and answer format. The concepts of Global Warming Potential (GWP) and Total Equivalent Warming Impact (TEWI) are explained. GWP is an index which allows a simple comparison to be make between the warming effects of different gases on a kg to kg basis relative to carbon. The GWP depends both on the lifetime of a substance in the atmosphere and its infra-red absorption capacity. The overall warming effect of operating a refrigeration system for its entire life is measured by its TEWI. Chloroflourocarbons (CFCs) which have been widely used as refrigerants are powerful greenhouse gases with high GWPs. Because of the bank of CFCs in refrigerating systems, their levels in the atmosphere are still increasing and it will be some time before refrigerant changes will be effective in reducing the warming effects of refrigerant releases. Hydrocarbons, hydroflourocarbons and ammonia all have a part to play as substitute refrigerants. Refrigerator efficiency is very important in terms of reducing CO 2 emissions. (UK)

  15. Integrated capacity and inventory management with capacity acquisition lead times

    NARCIS (Netherlands)

    Mincsovics, G.Z.; Tan, T.; Alp, O.

    2009-01-01

    We model a make-to-stock production system that utilizes permanent and contingent capacity to meet non-stationary stochastic demand, where a constant lead time is associated with the acquisition of contingent capacity. We determine the structure of the optimal solution concerning both the

  16. Low Global Warming Potential Refrigerants for Commercial Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Vishaldeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Honeywell and the Oak Ridge National Laboratory (ORNL) is to develop a Life Cycle Climate Performance (LCCP) modeling tool for optimally designing HVAC&R equipment with lower life cycle greenhouse gas emissions, and the selection of alternative working fluids that reduce the greenhouse gas emissions of HVAC&R equipment. In addition, an experimental evaluation program is used to measure the coefficient of performance (COP) and refrigerating capacity of various refrigerant candidates, which have differing GWP values, in commercial refrigeration equipment. Through a cooperative effort between industry and government, alternative working fluids will be chosen based on maximum reduction in greenhouse gases at minimal cost impact to the consumer. This project will ultimately result in advancing the goals of reducing greenhouse gas emissions through the use of low GWP working fluids and technologies for HVAC&R and appliance equipment, resulting in cost-competitive products and systems.

  17. Refrigerated Warehouse Demand Response Strategy Guide

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Doug [VaCom Technologies, San Luis Obispo, CA (United States); Castillo, Rafael [VaCom Technologies, San Luis Obispo, CA (United States); Larson, Kyle [VaCom Technologies, San Luis Obispo, CA (United States); Dobbs, Brian [VaCom Technologies, San Luis Obispo, CA (United States); Olsen, Daniel [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-11-01

    This guide summarizes demand response measures that can be implemented in refrigerated warehouses. In an appendix, it also addresses related energy efficiency opportunities. Reducing overall grid demand during peak periods and energy consumption has benefits for facility operators, grid operators, utility companies, and society. State wide demand response potential for the refrigerated warehouse sector in California is estimated to be over 22.1 Megawatts. Two categories of demand response strategies are described in this guide: load shifting and load shedding. Load shifting can be accomplished via pre-cooling, capacity limiting, and battery charger load management. Load shedding can be achieved by lighting reduction, demand defrost and defrost termination, infiltration reduction, and shutting down miscellaneous equipment. Estimation of the costs and benefits of demand response participation yields simple payback periods of 2-4 years. To improve demand response performance, it’s suggested to install air curtains and another form of infiltration barrier, such as a rollup door, for the passageways. Further modifications to increase efficiency of the refrigeration unit are also analyzed. A larger condenser can maintain the minimum saturated condensing temperature (SCT) for more hours of the day. Lowering the SCT reduces the compressor lift, which results in an overall increase in refrigeration system capacity and energy efficiency. Another way of saving energy in refrigerated warehouses is eliminating the use of under-floor resistance heaters. A more energy efficient alternative to resistance heaters is to utilize the heat that is being rejected from the condenser through a heat exchanger. These energy efficiency measures improve efficiency either by reducing the required electric energy input for the refrigeration system, by helping to curtail the refrigeration load on the system, or by reducing both the load and required energy input.

  18. Achieving a table-like magnetocaloric effect and large refrigerant capacity in in situ multiphase Gd65Mn25Si10 alloys obtained by crystallization treatment

    International Nuclear Information System (INIS)

    Shen, X Y; Zhong, X C; Huang, X W; Mo, H Y; Feng, X L; Liu, Z W; Jiao, D L

    2017-01-01

    In situ multiphase structure Gd 65 Mn 25 Si 10 alloys were fabricated by melt spinning and subsequent crystallization treatment. In the process of crystallization, the α -Gd, GdMn 2 and Gd 5 Si 3 phases precipitate in the amorphous matrix in turn. The Curie temperature ( T C ) values for the α -Gd crystallization phase and amorphous matrix can be tailored by tuning the crystallization treatment time. All three multiphase alloys obtained by crystallization treatment at 637 K for 20, 30 and 40 min, respectively, undergo multiple successive magnetic phase transitions. A table-like magnetic entropy change over a wide temperature range (∼90–120 K) and a large full width at half maximum (Δ T FWHM ) magnetic entropy change (∼230 K) were achieved in the above-mentioned crystallized alloys, resulting in large refrigerant capacities (RCs). The enhanced RCs of the three crystallized alloys for a magnetic field change of 0–5 T are in the range of 541–614 J kg −1 . Large Δ T FWHM and RC values and a table-like (−Δ S M ) max feature obtained in in situ multiphase Gd 65 Mn 25 Si 10 crystallized alloys make them suitable for potential application in efficient Ericsson-cycle magnetic refrigeration working in a temperature range from 74 to 310 K. (paper)

  19. Measurement of the cooling capacity of an RMC-Cryosystems Model LTS 4.5-025 closed-cycle helium refrigerator

    Science.gov (United States)

    De Zafra, R. L.; Mallison, W. H.; Emmons, L. K.; Koller, D.

    1991-01-01

    The cooling capacity of a recently purchased RMC-Cryosystems Model LTS 4.5-025 closed-cycle He refrigerator was measured over the range 4-35 K. It is found that the nominal cooling capacity of 250 mW is only met or exceeded over a narrow temperature range around 4.3 + or - 0.5 K, and that, above this range, there exists a considerable region of much lower cooling capacity, not exceeding about 100 mW. It is believed that this behavior results from use of a fixed-aperture Joule-Thompson expansion valve, and might be alleviated if the J-T valve could be adjusted to compensate for changing flow within the 5-20 K temperature range. Present performance may severely limit or prevent effective use in applications where an irreducible heat inflow exists which is greater than about 100 mW, yet substantially less than the quoted capacity at about 4 K.

  20. Managing the market risk in pipeline capacity positions

    International Nuclear Information System (INIS)

    Simard, T.S.

    1998-01-01

    Managing the risk involved in adding new pipeline capacity was explored in this presentation. Topics discussed included: (1) pipeline capacity positions as basis swaps, (2) physical capacity versus basis transactions, (3) managing the market price risk in a capacity position, and (4) sharing of pipeline market risk. Pipeline owners were advised to recognize that pipeline capacity carries significant market price risk, that basis markets can sometimes be more volatile than outright markets, and to treat physical capacity market risk the same way as one would treat a financial basis position. 2 figs

  1. Thermoacoustic refrigeration

    Science.gov (United States)

    Garrett, Steven L.; Hofler, Thomas J.

    1991-12-01

    A new refrigerator which uses resonant high amplitude sound in inert gases to pump heat is described and demonstrated. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). The thermoacoustic refrigerator has no sliding seals, requires no lubrication, uses only low-tolerance machine parts, and contains no expensive components. Because the compressor moving mass is typically small and the oscillation frequency is high, the small amount of vibration is very easily isolated. This low vibration and lack of sliding seals makes thermoacoustic refrigeration an excellent candidate for food refrigeration and commercial/residential air conditioning applications. The design, fabrication, and performance of the first practical, autonomous thermoacoustic refrigerator, which will be flown on the Space Shuttle (STS-42), are described, and designs for terrestrial applications are presented.

  2. 46 CFR 154.702 - Refrigerated carriage.

    Science.gov (United States)

    2010-10-01

    ... Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1) Have enough capacity to maintain the cargo vapor pressure in each cargo tank served by the system below... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...

  3. Flammable refrigerants

    NARCIS (Netherlands)

    Gerwen, R.J.M. van; Verwoerd, M.; Oostendorp, P.A.

    1999-01-01

    Hydrocarbons are promising alternatives for CFC, HCFC and HFC refrigerants. Due to their flammable nature, safety aspects have to be considered carefully. The world-wide situation concerning acceptability and practical application of flammable refrigerants is becoming more and more complex and

  4. Managing fleet capacity effectively under second-hand market redistribution.

    Science.gov (United States)

    Quillérou, Emmanuelle; Roudaut, Nolwenn; Guyader, Olivier

    2013-09-01

    Fishing capacity management policies have been traditionally implemented at national level with national targets for capacity reduction. More recently, capacity management policies have increasingly targeted specific fisheries. French fisheries spatially vary along the French coastline and are associated to specific regions. Capacity management policies, however, ignore the capital mobility associated with second-hand vessel trade between regions. This is not an issue for national policies but could limit the effectiveness of regional capacity management policies. A gravity model and a random-effect Poisson regression model are used to analyze the determinants and spatial extent of the second-hand market in France. This study is based on panel data from the French Atlantic Ocean between 1992 and 2009. The trade flows between trading partners is found to increase with their sizes and to be spatially concentrated. Despite the low trade flows between regions, a net impact analysis shows that fishing capacity is redistributed by the second-hand market to regions on the Channel and Aquitaine from central regions. National capacity management policies (constructions/destructions) have induced a net decrease in regional fleet capacity with varying magnitude across regions. Unless there is a change of policy instruments or their scale of implementation, the operation of the second-hand market decreases the effectiveness of regional capacity management policies in regions on the Channel and Aquitaine.

  5. Application genetic algorithms for load management in refrigerated warehouses with wind power penetration

    DEFF Research Database (Denmark)

    Zong, Yi; Cronin, Tom; Gehrke, Oliver

    2009-01-01

    Wind energy is produced at random times, whereas the energy consumption pattern shows distinct demand peaks during day-time and low levels during the night. The use of a refrigerated warehouse as a giant battery for wind energy is a new possibility that is being studied for wind energy integratio...

  6. Combined heat and power generation with exhaust-heated two-stage absorption refrigerator. Performance of a pilot installation with a refrigeration capacity of 350 kW; Kraft-Waerme-Kaelte-Kopplung mit Abgas-Beheizter zweistufiger Absorptionskaeltemaschine. Betriebserfahrungen einer Pilotinstallation mit 350 kW Kaelteleistung

    Energy Technology Data Exchange (ETDEWEB)

    Plura, S.; Baumeister, D.; Koeberle, T.; Radspieler, M.; Schweigler, C. [Bayerisches Zentrum fuer Angewandte Energieforschung e.V. (ZAE Bayern), Garching (Germany)

    2007-07-01

    A new system concept for higher efficiency of cogeneration systems is developed in which a cogeneration unit is combined with a two-stage absorption refrigerator, and the waste heat of the cogeneration unit is directly passed on into the regenerator of the absorption refrigerator. The higher temperature level of the waste heat makes it possible to use a two-stage absorption cycle for higher energy efficiency. For simultaneous utilisation of low-temperature heat, the two-stage cycle is combined with a one-stage cycle for additional heat supply at a lower temperature level so that the exhaust of a typical cogeneration unit will be cooled to about 120 degC. At the same time, further waste heat of the cogeneration unit will be transferred to the heat pump via a hot water circuit. This concept with a combined single-stage and two-stage absorption circuit is referred to as a double-effect/single-effect circuit. The new system is used for energy supply in a spa, where the two-stage absorption refrigerator cools the water used for swimming pool cleaning with a refrigerating capacity of 350 kW and provides low-temperature heat for swimming pool heating with a capacity of 700 kW. (orig.)

  7. Building Capacity for Protected Area Management in Lao PDR

    Science.gov (United States)

    Rao, Madhu; Johnson, Arlyne; Spence, Kelly; Sypasong, Ahnsany; Bynum, Nora; Sterling, Eleanor; Phimminith, Thavy; Praxaysombath, Bounthob

    2014-04-01

    Declining biodiversity in protected areas in Laos is attributed to unsustainable exploitation of natural resources. At a basic level, an important need is to develop capacity in academic and professional training institutions to provide relevant training to conservation professionals. The paper (a) describes the capacity building approach undertaken to achieve this goal, (b) evaluates the effectiveness of the approach in building capacity for implementing conservation and (c) reviews implementation outcomes. Strong linkages between organizations implementing field conservation, professional training institutions, and relevant Government agencies are central to enhancing effectiveness of capacity building initiatives aimed at improving the practice of conservation. Protected area management technical capacity needs will need to directly influence curriculum design to insure both relevance and effectiveness of training in improving protected area management. Sustainability of capacity building initiatives is largely dependent on the level of interest and commitment by host-country institutions within a supportive Government policy framework in addition to engagement of organizations implementing conservation.

  8. Energy efficient control of a refrigeration plant

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Larsen, Lars F. S.

    2009-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The new idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design...... and the methods are evaluated with respect to energy efficiency....

  9. Developing Capacities in Radioactive Waste Management

    International Nuclear Information System (INIS)

    Yusuf, Omar

    2014-01-01

    As the Agency’s main service-delivery mechanism, the IAEA’s technical cooperation (TC) programme plays a large part in supporting radioactive waste management around the world, helping to share information on the topic, and training personnel in the proper treatment and disposal of radioactive waste. The TC programme supports the development of policies and strategies, the assessment and upgrading (if necessary) of existing facilities, and the implementation of new management facilities, especially for near surface disposal. The programme also helps to develop competence in geological disposal for Member States operating nuclear power plants. This article presents just a few project examples to illustrate the scope of the programme

  10. Improving regulatory capacity to manage risks associated with trade agreements.

    Science.gov (United States)

    Walls, Helen L; Smith, Richard D; Drahos, Peter

    2015-03-21

    Modern trade negotiations have delivered a plethora of bilateral and regional preferential trade agreements (PTAs), which involve considerable risk to public health, thus placing demands on governments to strengthen administrative regulatory capacities in regard to the negotiation, implementation and on-going management of PTAs. In terms of risk management, the administrative regulatory capacity requisite for appropriate negotiation of PTAs is different to that for the implementation or on-going management of PTAs, but at all stages the capacity needed is expensive, skill-intensive and requires considerable infrastructure, which smaller and poorer states especially struggle to find. It is also a task generally underestimated. If states do not find ways to increase their capacities then PTAs are likely to become much greater drivers of health inequities. Developing countries especially struggle to find this capacity. In this article we set out the importance of administrative regulatory capacity and coordination to manage the risks to public health associated with PTAs, and suggest ways countries can improve their capacity.

  11. Recent investigations on refrigerants for magnetic refrigerators

    International Nuclear Information System (INIS)

    Hashimoto, T.

    1986-01-01

    In development of the magnetic refrigerator, an important problem is selection of magnetic materials as refrigerants. The main purpose of the present paper is to discuss the magnetic and thermal properties necessary for these refrigerants and to report recent investigations. Magnetic refrigerants can be expediently divided into two groups, one for the Carnottype magnetic refrigerator below 20 K and the other for the Ericsson-type refrigerator. The required physical properties of refrigerants in each type of the magnetic refrigerator are first discussed. And then, the results of recent investigations on the magnetic, thermal and magnetocaloric characters of several promising magnetic refrigerants are shown. Finally, a brief prospect of the magnetic refrigerants and refrigerators is given

  12. Role of subsidies in EU fleet capacity management

    DEFF Research Database (Denmark)

    Lindebo, Erik

    2005-01-01

    Fisheries in the European Union (EU) continue to be overexploited by an overcapitalised fishing fleet, despite the best intentions of two decades of capacity adjustment programmes. This paper considers the progress of fishing capacity under the Multi-annual Guidance Programme and examines the imp...... of vessel decommissioning. The Danish fishing fleet case serves as an empirical example in this regard. Comments on the future capacity management regime and the role of subsidies in EU fisheries are offered.......Fisheries in the European Union (EU) continue to be overexploited by an overcapitalised fishing fleet, despite the best intentions of two decades of capacity adjustment programmes. This paper considers the progress of fishing capacity under the Multi-annual Guidance Programme and examines...

  13. Optimum operating regimes of common paramagnetic refrigerants

    CERN Document Server

    Wikus, P; Figueroa-Feliciano, E

    2011-01-01

    Adiabatic Demagnetization Refrigerators (ADRs) are commonly used in cryogenic laboratories to achieve subkelvin temperatures. ADRs are also the technology of choice for several space borne instruments which make use of cryogenic microcalorimeters or bolometers {[}1-4]. For these applications, refrigerants with high ratios of cooling capacity to volume, or cooling capacity to mass are usually required. In this manuscript, two charts for the simple selection of the most suitable of several common refrigerants (CAA, CMN, CPA, DGG, FAA, GGG, GLF and MAS) are presented. These graphs are valid for single stage cycles. The selection of the refrigerants is uniquely dependent on the starting conditions of the refrigeration cycle (temperature and magnetic field density) and the desired final temperature. Only thermodynamic properties of the refrigerants have been taken into account, and other important factors such as availability and manufacturability have not been considered. (C) 2011 Elsevier Ltd. All rights reserve...

  14. Optimal design of gas adsorption refrigerators for cryogenic cooling

    Science.gov (United States)

    Chan, C. K.

    1983-01-01

    The design of gas adsorption refrigerators used for cryogenic cooling in the temperature range of 4K to 120K was examined. The functional relationships among the power requirement for the refrigerator, the system mass, the cycle time and the operating conditions were derived. It was found that the precool temperature, the temperature dependent heat capacities and thermal conductivities, and pressure and temperature variations in the compressors have important impacts on the cooling performance. Optimal designs based on a minimum power criterion were performed for four different gas adsorption refrigerators and a multistage system. It is concluded that the estimates of the power required and the system mass are within manageable limits in various spacecraft environments.

  15. Capacity Building for Institutional Development in Surveying and Land Management

    DEFF Research Database (Denmark)

    Enemark, Stig

    2006-01-01

    for developing the basic capacity in terms of educational programs and professional organizations; and 3) Global development through cooperation with other international NGO´s such as the UN agencies, the World Bank and sister organizations in surveying. FIG, this way, plays a strong role, in improving...... for institutional development within surveying and land management. Finally the paper discusses the role of FIG in this regard. Three areas are identified: 1) Professional development through providing a global forum for exchange of experiences and new developments; 2) Institutional development through support...... the capacity in surveying and land management at a global scale....

  16. Adaptive capacity and community-based natural resource management.

    Science.gov (United States)

    Armitage, Derek

    2005-06-01

    Why do some community-based natural resource management strategies perform better than others? Commons theorists have approached this question by developing institutional design principles to address collective choice situations, while other analysts have critiqued the underlying assumptions of community-based resource management. However, efforts to enhance community-based natural resource management performance also require an analysis of exogenous and endogenous variables that influence how social actors not only act collectively but do so in ways that respond to changing circumstances, foster learning, and build capacity for management adaptation. Drawing on examples from northern Canada and Southeast Asia, this article examines the relationship among adaptive capacity, community-based resource management performance, and the socio-institutional determinants of collective action, such as technical, financial, and legal constraints, and complex issues of politics, scale, knowledge, community and culture. An emphasis on adaptive capacity responds to a conceptual weakness in community-based natural resource management and highlights an emerging research and policy discourse that builds upon static design principles and the contested concepts in current management practice.

  17. Capacity Management as a Service for Enterprise Standard Software

    Directory of Open Access Journals (Sweden)

    Hendrik Müller

    2017-12-01

    Full Text Available Capacity management approaches optimize component utilization from a strong technical perspective. In fact, the quality of involved services is considered implicitly by linking it to resource capacity values. This practice hinders to evaluate design alternatives with respect to given service levels that are expressed in user-centric metrics such as the mean response time for a business transaction. We argue that utilized historical workload traces often contain a variety of performance-related information that allows for the integration of performance prediction techniques through machine learning. Since enterprise applications excessively make use of standard software that is shipped by large software vendors to a wide range of customers, standardized prediction models can be trained and provisioned as part of a capacity management service which we propose in this article. Therefore, we integrate knowledge discovery activities into well-known capacity planning steps, which we adapt to the special characteristics of enterprise applications. Using a real-world example, we demonstrate how prediction models that were trained on a large scale of monitoring data enable cost-efficient measurement-based prediction techniques to be used in early design and redesign phases of planned or running applications. Finally, based on the trained model, we demonstrate how to simulate and analyze future workload scenarios. Using a Pareto approach, we were able to identify cost-effective design alternatives for an enterprise application whose capacity is being managed.

  18. Technical and institutional capacity in local organisations to manage ...

    African Journals Online (AJOL)

    Technical and institutional capacity in local organisations to manage decentralised forest resources in Uganda. ... Southern Forests: a Journal of Forest Science ... to implement decentralised forest governance exists in local organisations through partnerships with other actors in the productive use of the available resources.

  19. Change Management and Capacity Building for Regional Banking ...

    African Journals Online (AJOL)

    From the regulatory authorities led by the Central Bank of Nigeria (CBN), to each of the 25 banks that emerged, the successful conclusion of the first phase of banking reforms demonstrates a level of change management capacity deemed vital in successful corporate transformation. However, to successfully position ...

  20. Thailand's National Nutritional Program : Lessons in Management and Capacity Development

    OpenAIRE

    Heaver, Richard; Kachondam, Yongyout

    2002-01-01

    Thailand's community nutrition program has been the most successful in Asia. This paper looks at what made it work from a management and capacity development point of view. Key lessons are identified in the following areas: Building a strong consensus at national and local levels about the importance of nutrition as an investment in the country's future, rather than as a welfare expenditur...

  1. Environmentally benign working pairs for adsorption refrigeration

    International Nuclear Information System (INIS)

    Cui Qun; Tao Gang; Chen Haijun; Guo Xinyue; Yao Huqing

    2005-01-01

    This paper begins from adsorption working pairs: water and ethanol were selected as refrigerants; 13x molecular sieve, silica gel, activated carbon, adsorbent NA and NB, proposed by authors, were selected as adsorbents, and the performance of adsorption working pairs in adsorption refrigeration cycle was studied. The adsorption isotherms of adsorbents (NA and NB) were obtained by high-vacuum gravimetric method. Desorption properties of adsorbents were analyzed and compared by thermal analysis method. The performance of adsorption refrigeration was studied on simulation device of adsorption refrigeration cycle. After presentation of adsorption isotherms, the thermodynamic performance for their use in adsorption refrigeration system was calculated. The results show: (1) the maximum adsorption capacity of water on adsorbent NA reaches 0.7 kg/kg, and the maximum adsorption capacity of ethanol on adsorbent NB is 0.68 kg/kg, which is three times that of ethanol on activated carbon, (2) the refrigeration capacity of NA-water working pair is 922 kJ/kg, the refrigeration capacity of NB-ethanol is 2.4 times that of activated carbon-methanol, (3) as environmental friendly and no public hazard adsorption working pair, NA-H 2 O and NB-ethanol can substitute activated carbon-methanol in adsorption refrigeration system using low-grade heat source

  2. The capacity building of disaster management in Bojonegoro regency

    Science.gov (United States)

    Isbandono, P.; Prastyawan, A.; Gamaputra, G.

    2018-01-01

    East Java is a disaster-prone area. Head of the National Disaster Management Agency, Syamsul Maarif (2012) states that “East Java is a disaster supermarket area. Referring to Act Number 24 Year 2007 Concerning Disaster Management, disaster prevention activities are a series of activities undertaken as an effort to eliminate and/or reduce the threat of disaster (Article 1, paragraph 6).The disaster mitigation is a series of efforts to reduce disaster risk, through physical development and awareness and capacity building in the face of disaster (Article 1, paragraph 9). In 2009, the Provincial Government of East Java has been established Regional Disaster Management Agency and complete it through Local Regulation of East Java Province Number 3 Year 2010. This research was conducted in Bojonegoro. This study described the capacity building disaster handling and used descriptive research with qualitative approach. It focused on the capacity building for community preparedness in the face of. This study showed the vulnerability of regions and populations to threats flood and drought in could be physical, social and/or economical. The aims of the capacity building for the individuals and organizations are to be used effectively and efficiently in order to achieve the goals of the individuals and organizations.

  3. Intermediate Collaborative Adaptive Management Strategies Build Stakeholder Capacity

    Directory of Open Access Journals (Sweden)

    Martha C. Monroe

    2013-06-01

    Full Text Available Efforts to implement collaborative adaptive management (CAM often suffer from challenges, such as an unwillingness of managers to share power, unresolved conflicts between stakeholders, and lack of capacity among stakeholders. Some aspects considered essential to CAM, e.g., trust and stakeholder capacity, may be more usefully viewed as goals for intermediate strategies rather than a set of initial conditions. From this perspective, intermediate steps that focus on social learning and building experience could overcome commonly cited barriers to CAM. An exploration of Springs Basin Working Groups, organized around major clusters of freshwater springs in north Florida, provides a case study of how these intermediate steps enable participants to become more reasonable and engaged. This strategy may be easily implemented by agencies beginning a CAM process.

  4. It Systems Supporting the Management of Production Capacity

    Science.gov (United States)

    Milewska, Elżbieta

    2017-03-01

    The paper presents the problem of manufacturing process flexibility in view of a company's material and information flow stream management. The author of the article has described the functions of a production process control system and presented the characteristics of production capacity intensive and extensive reserves. The MRP II/ERP, MES and APS class IT tools supporting the process of production planning, organization and control have also been discussed.

  5. IT SYSTEMS SUPPORTING THE MANAGEMENT OF PRODUCTION CAPACITY

    Directory of Open Access Journals (Sweden)

    Elżbieta MILEWSKA

    2017-01-01

    Full Text Available The paper presents the problem of manufacturing process flexibility in view of a company’s material and information flow stream management. The author of the article has described the functions of a production process control system and presented the characteristics of production capacity intensive and extensive reserves. The MRP II/ERP, MES and APS class IT tools supporting the process of production planning, organization and control have also been discussed.

  6. IT SYSTEMS SUPPORTING THE MANAGEMENT OF PRODUCTION CAPACITY

    OpenAIRE

    Elżbieta MILEWSKA

    2017-01-01

    The paper presents the problem of manufacturing process flexibility in view of a company’s material and information flow stream management. The author of the article has described the functions of a production process control system and presented the characteristics of production capacity intensive and extensive reserves. The MRP II/ERP, MES and APS class IT tools supporting the process of production planning, organization and control have also been discussed.

  7. APPLICATION OF QUALITY ECONOMY METHODS IN MANAGING INNOVATION CAPACITY DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    V. V. Okrepilov

    2017-01-01

    Full Text Available Purpose: to reveal the possibilities of applying the methods of the quality economy to improve the management efficiency of the development of the region's innovative potential.Results: in the article topical questions of development of innovative potential of the region are considered - one of the important factors providing improvement of quality of life of the population and sustainable development of the territory. The content of the concept of "innovation potential of the region" is disclosed and its components are described. The purposes of development of innovative potential are considered. A comparative analysis of the methods of managing the development of potential in the market and planned economy is carried out. Particular attention is paid to the application of quality management methods to improve management effectiveness. In conclusion, the advantages and disadvantages of the economy of the macro-region "North-West" from the point of view of transition to an innovative development path, as well as scenarios for the development of the economy, are discussed.Conclusions and relevance: the use of quality economy tools to manage the development of innovative capacity will help to avoid mistakes and choose the right directions for development. In the era of globalization, improving quality is a prerequisite for successful competition in world markets. Therefore, the issues of innovation capacity assessment should be taken into account in the development of regional plans and programs, as well as socio-economic policy.

  8. Office of Civilian Radioactive Waste Management: Annual capacity report

    International Nuclear Information System (INIS)

    1987-06-01

    The system configuration used as the basis for this report is defined in the Mission Plan Amendment. It includes a Monitored Retrievable Storage (MRS) facility as an integral system component. During the first 10 years of WMS operation, the total quantity of spent fuel that could be accepted is 18,600 metric tons uranium (MTU). By starting WMS operations in 1998, the MRS facility could accept 6000 MTU of spent fuel by the time repository operations are projected to begin in 2003. The allocation of acceptance right is currently based on the projected annual capacity of the waste management system to receive SNF and the age of permanently discharged spent fuel. The allocations are based on the oldest fuel having the highest priority. Section 1.0 provides a discussion of the requirement for the (ACR) and the role the ACR will play in DOE's interaction with the Purchasers in implementing the provisions of the Standard Disposal Contract. The currently projected annual acceptance capacity to be allocated is discussed and presented in Section 2.0. Section 3.0 discusses the procedure and basis for allocation of this capacity (acceptance rights). Allocation will be based on the chronological listing of spent fuel assemblies and equivalent MTU. Some of the contingencies which may have an impact on Contract implementation and system operation considerations which could affect the projected annual capacity and its allocation are identified in Section 4.0. 4 refs., 11 tabs

  9. Análisis del comportamiento de la capacidad frigorífica en compresores herméticos en Cuba. // Behaviour of the refrigeration capacity in hermetic compressors.

    Directory of Open Access Journals (Sweden)

    K. Arencibia Avila

    2004-09-01

    Full Text Available El índice de roturas de los compresores herméticos en Cuba (4 % se encuentra muy por encima de los estándaresinternacionales de calidad (0, 04 %. El objetivo del trabajo que se presenta fue la determinación de la capacidad frigoríficaa tres tipos de compresores herméticos diferentes en condiciones ambientales como las existentes en el país. Las pruebasexperimentales se realizaron en laboratorios certificados por las normas ISO 9002 e ISO 14 000.El análisis muestra que se pierde más del 10 % de la capacidad frigorífica del compresor. De ello se deduce que la simpletransferencia de tecnología no puede ser una solución para las necesidades crecientes de equipos de refrigeración en el país.Los equipos y sistemas de este tipo tienen que ser diseñados especialmente para las condiciones cubanas con el objetivo delograr eficiencias aceptables, equivalentes a la media mundial y acorde a la situación energética que afronta el mundoactualmente.Palabras claves: Compresores herméticos, refrigeración.___________________________________________________________________________Abstract.The break rate of hermetic compressors in Cuba (4% is well over the international standards of quality (0. 04 %. Thepurpose of this word was to determine the refrigeration capacity to three kinds of hermetic compressors in environmentalconditions like the ones existing in the country. The experimental test were carried out in laboratories certified by ISO 9002and ISO 14 000.The analysis shows that more than 10 % of the refrigeration capacity of the compressors is lost. We can say that a simpletransference of technology cannot be a solution to the increasing needs of refrigeration equipment. The systems andequipment of this kind have to be specially designed to meet our conditions, with the aim of achieving acceptableefficiencies, similar to those of the world average, and according to the energy situation that the world is facing nowadays.Key Words: Hermetic

  10. Research Data Management - Building Service Infrastructure and Capacity

    KAUST Repository

    Baessa, Mohamed A.

    2018-03-07

    Research libraries support the missions of their institutions by facilitating the flow of scholarly information to and from the institutions’ researchers. As research in many disciplines becomes more data and software intensive, libraries are finding that services and infrastructure developed to preserve and provide access to textual documents are insufficient to meet their institutions’ needs. In response, libraries around the world have begun assessing the data management needs of their researchers, and expanding their capacity to meet the needs that they find. This discussion panel will discuss approaches to building research data management services and infrastructure in academic libraries. Panelists will discuss international efforts to support research data management, while highlighting the different models that universities have adopted to provide a mix of services and infrastructure tailored to their local needs.

  11. Stirling Refrigerator

    Science.gov (United States)

    Kagawa, Noboru

    A Stirling cooler (refrigerator) was proposed in 1862 and the first Stirling cooler was put on market in 1955. Since then, many Stirling coolers have been developed and marketed as cryocoolers. Recently, Stirling cycle machines for heating and cooling at near-ambient temperatures between 173 and 400K, are recognized as promising candidates for alternative system which are more compatible with people and the Earth. The ideal cycles of Stirling cycle machine offer the highest thermal efficiencies and the working fluids do not cause serious environmental problems of ozone depletion and global warming. In this review, the basic thermodynamics of Stirling cycle are briefly described to quantify the attractive cycle performance. The fundamentals to realize actual Stirling coolers and heat pumps are introduced in detail. The current status of the Stirling cycle machine technologies is reviewed. Some machines have almost achieved the target performance. Also, duplex-Stirling-cycle and Vuilleumier-cycle machines and their performance are introduced.

  12. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1998-03-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to thermophysical properties, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air conditioning and refrigeration equipment. It also references documents addressing compatibility of refrigerants and lubricants with other materials.

  13. Modeling and calculation of open carbon dioxide refrigeration system

    International Nuclear Information System (INIS)

    Cai, Yufei; Zhu, Chunling; Jiang, Yanlong; Shi, Hong

    2015-01-01

    Highlights: • A model of open refrigeration system is developed. • The state of CO 2 has great effect on Refrigeration capacity loss by heat transfer. • Refrigeration capacity loss by remaining CO 2 has little relation to the state of CO 2 . • Calculation results are in agreement with the test results. - Abstract: Based on the analysis of the properties of carbon dioxide, an open carbon dioxide refrigeration system is proposed, which is responsible for the situation without external electricity unit. A model of open refrigeration system is developed, and the relationship between the storage environment of carbon dioxide and refrigeration capacity is conducted. Meanwhile, a test platform is developed to simulation the performance of the open carbon dioxide refrigeration system. By comparing the theoretical calculations and the experimental results, several conclusions are obtained as follows: refrigeration capacity loss by heat transfer in supercritical state is much more than that in two-phase region and the refrigeration capacity loss by remaining carbon dioxide has little relation to the state of carbon dioxide. The results will be helpful to the use of open carbon dioxide refrigeration

  14. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1999-01-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  15. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-07-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  16. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-11-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  17. Optimization Model for Capacity Management and Bed Scheduling for Hospital

    Science.gov (United States)

    Sitepu, Suryati; Mawengkang, Herman; Husein, Ismail

    2018-01-01

    Hospital is a very important institution to provide health care for people. It is not surprising that nowadays the people’s demands for hospital is increasing.. However, due to the rising cost of healthcare services, hospitals need to consider efficiencies in order to overcome these two problems. This paper deals with an integrated strategy of staff capacity management and bed allocation planning to tackle these problems. Mathematically, the strategy can be modeled as an integer linear programming problem. We solve the model using a direct neighborhood search approach, based on the notion of superbasic variables.

  18. Capacity management of nursing staff as a vehicle for organizational improvement

    NARCIS (Netherlands)

    Elkhuizen, Sylvia G.; Bor, Gert; Smeenk, Marjolein; Klazinga, Niek S.; Bakker, Piet J. M.

    2007-01-01

    Background: Capacity management systems create insight into required resources like staff and equipment. For inpatient hospital care, capacity management requires information on beds and nursing staff capacity, on a daily as well as annual basis. This paper presents a comprehensive capacity model

  19. Increasing capacity to deliver diabetes self-management education

    DEFF Research Database (Denmark)

    Carey, M. E.; Mandalia, P. K.; Daly, H.

    2014-01-01

    Aim: To develop and test a format of delivery of diabetes self-management education by paired professional and lay educators. Methods: We conducted an equivalence trial with non-randomized participant allocation to a Diabetes Education and Self Management for Ongoing and Newly Diagnosed Type 2 di...... educator role can provide equivalent patient benefits. This could provide a method that increases capacity, maintains quality and is cost-effective, while increasing access to self-management education.......Aim: To develop and test a format of delivery of diabetes self-management education by paired professional and lay educators. Methods: We conducted an equivalence trial with non-randomized participant allocation to a Diabetes Education and Self Management for Ongoing and Newly Diagnosed Type 2...... diabetes (DESMOND) course, delivered in the standard format by two trained healthcare professional educators (to the control group) or by one trained lay educator and one professional educator (to the intervention group). A total of 260 people with Type 2 diabetes diagnosed within the previous 12 months...

  20. Office of Civilian Radioactive Waste Management annual capacity report

    International Nuclear Information System (INIS)

    1990-12-01

    The Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (10 CRF 961) requires the Department of Energy (DOE) to issue and Annual Capacity Report (ACR) for planning purposes. This report is currently scheduled to be the last in the series of ACRs to be published by DOE. The Standard Disposal Contract states that beginning in April 1991, DOE will publish the first annual Acceptance Priority Ranking report which will formally set forth the acceptance queue in which Purchasers will receive priority for allocation of the Waste Management System (WMS) acceptance capacity. This 1990 issue of the ACR utilizes two projected WMS waste acceptance schedules as the bases for allocation of acceptance capacity to the Purchasers for a 10-year period following the projected commencement of facility operations. The acceptance schedules were selected to be representative of upper and lower boundaries for a WMS which includes a Monitored Retrievable Storage (MRS) facility capable of receiving and storing SNF starting in 1998. 6 refs., 4 tabs

  1. Economic analysis of gradual "social exhaustion" of waste management capacity.

    Science.gov (United States)

    Koide, Hideo; Nakayama, Hirofumi

    2013-12-01

    This article proposes to analyze the quantitative effects of a gradual physical and "social" exhaustion of a landfill site on an equilibrium waste management service. A gradual social exhaustion of a landfill is defined here as an upward shift of a "subjective factor" associated with the amount of waste, based on the plausible hypothesis that an individual will not accept excessive presence of landfilled waste. Physical exhaustion occurs when the absolute capacity of a landfill site decreases. The paper shows some numerical examples using specific functions and parameters, and proposes appropriate directions for three policy objectives: to decrease the equilibrium waste disposal, to increase the economic surplus of the individual and/or the waste management firm, and to lower the equilibrium collection fee. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  2. Energy consumption of small refrigerators - Information leaflet; Merkblatt Kleinkuehlschrank

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    In this leaflet published by the Swiss Federal Office of Energy (SFOE), the energy consumption of small refrigerators with a capacity of less than 100 litres is reported on. Such small refrigerators are often used in hotel rooms or in campers. It is noted that, in comparison, a typical, 150 litre class A++ domestic refrigerator uses only a fraction of the amount of energy used by such small refrigerators. The results of measurements made according to EN 153 and ISO 15502 norms are discussed. Recommendations are made on the purchase and operation of these small refrigerators.

  3. Nonlinear Superheat Control of a Refrigeration Plant using Backstepping

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2008-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The main idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design...... of a nonlinear controller. The proposed method is validated by experimental results....

  4. Refrigeration generation using expander-generator units

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Koryagin, A. V.; Baidakova, Yu. O.

    2016-05-01

    The problems of using the expander-generator unit (EGU) to generate refrigeration, along with electricity were considered. It is shown that, on the level of the temperatures of refrigeration flows using the EGU, one can provide the refrigeration supply of the different consumers: ventilation and air conditioning plants and industrial refrigerators and freezers. The analysis of influence of process parameters on the cooling power of the EGU, which depends on the parameters of the gas expansion process in the expander and temperatures of cooled environment, was carried out. The schematic diagram of refrigeration generation plant based on EGU is presented. The features and advantages of EGU to generate refrigeration compared with thermotransformer of steam compressive and absorption types were shown, namely: there is no need to use the energy generated by burning fuel to operate the EGU; beneficial use of the heat delivered to gas from the flow being cooled in equipment operating on gas; energy production along with refrigeration generation, which makes it possible to create, using EGU, the trigeneration plants without using the energy power equipment. It is shown that the level of the temperatures of refrigeration flows, which can be obtained by using the EGU on existing technological decompression stations of the transported gas, allows providing the refrigeration supply of various consumers. The information that the refrigeration capacity of an expander-generator unit not only depends on the parameters of the process of expansion of gas flowing in the expander (flow rate, temperatures and pressures at the inlet and outlet) but it is also determined by the temperature needed for a consumer and the initial temperature of the flow of the refrigeration-carrier being cooled. The conclusion was made that the expander-generator units can be used to create trigeneration plants both at major power plants and at small energy.

  5. Principles of capacity management, applied in the mental health context.

    Science.gov (United States)

    Zeitz, Kathryn; Watson, Darryl

    2017-06-22

    Objective The aim of the paper was to describe a suite of capacity management principles that have been applied in the mental health setting that resulted in a significant reduction in time spent in two emergency departments (ED) and improved throughput. Methods The project consisted of a multifocal change approach over three phases that included: (1) the implementation of a suite of fundamental capacity management activities led by the service and clinical director; (2) a targeted Winter Demand Plan supported by McKinsey and Co.; and (3) a sustainability of change phase. Descriptive statistics was used to analyse the performance data that was collected through-out the project. Results This capacity management project has resulted in sustained patient flow improvement. There was a reduction in the average length of stay (LOS) in the ED for consumers with mental health presentations to the ED. At the commencement of the project, in July 2014, the average LOS was 20.5h compared with 8.5h in December 2015 post the sustainability phase. In July 2014, the percentage of consumers staying longer than 24h was 26% (n=112); in November and December 2015, this had reduced to 6% and 7 5% respectively (less than one consumer per day). Conclusion Improving patient flow is multifactorial. Increased attendances in public EDs by people with mental health problems and the lengthening boarding in the ED affect the overall ED throughput. Key strategies to improve mental health consumer flow need to focus on engagement, leadership, embedding fundamentals, managing and target setting. What is known about the topic? Improving patient flow in the acute sector is an emerging topic in the health literature in response to increasing pressures of access block in EDs. What does this paper add? This paper describes the application of a suite of patient flow improvement principles that were applied in the mental health setting that significantly reduced the waiting time for consumers in two EDs

  6. Analysis of cooldown performance for Isabelle helium refrigerator

    International Nuclear Information System (INIS)

    Wu, K.C.; Brown, D.P.; Moore, R.W.

    1982-01-01

    The cooldown performance for the ISABELLE Helium refrigerator is analyzed in terms of the relationship between refrigerator and its load. The flow diagram for ISABELLE with its redundant turbines and heat exchangers is given. Cycle description and procedure for cooldown is described with the relationship between a refrigerator and its load illustrated. Pressure vs. temperature for ISABELLE load and the efficiency for a turbine are illustrated. The procedure for modeling the refrigerator and the concepts of maximizing the cooldown capacity are described. The results and discussion are accompanied with T-S diagrams for initial stage of cooldown and refrigerator characteristic at various return temperatures. The ISABELLE refrigerator with its reduncant expanders properly used achieves cooldown capacity well beyond its steady-state capacity. The cooldown rate at this stage relies on the design safety margin, which for the ISABELLE is 50%

  7. Method and refrigerants for replacing existing refrigerants in centrifugal compressors

    International Nuclear Information System (INIS)

    Kopko, W.L.

    1991-01-01

    This patent describes a method for replacing an existing refrigerant in a centrifugal compressor. It comprises selecting a desired impeller Mach number for the centrifugal compressor; selecting a base refrigerant constituent; combining at least one additive refrigerant constituent with the base refrigerant constituent to form a replacement refrigerant having at least one physical or chemical property different from the existing refrigerant and substantially providing the desired impeller Mach number in the centrifugal compressor; and replacing the existing refrigerant with the replacement refrigerant

  8. Refrigeration system having standing wave compressor

    Science.gov (United States)

    Lucas, Timothy S.

    1992-01-01

    A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

  9. ESO2 Optimization of Supermarket Refrigeration Systems

    DEFF Research Database (Denmark)

    Petersen, Lars Norbert; Madsen, Henrik; Heerup, Christian

    Supermarket refrigeration systems consists of a number of display cases, cooling cabinets and cold rooms connected to a central compressor pack. This configuration saves energy compared to placing a compressor at each cooling site. The classical control setup of a supermarket refrigeration system...... in the supermarket. The first approach to solve this problem is to design an overall control system which coordinates the compressor capacity and the current refrigeration load. The drawback of this approach is the complexity of the single controller. The solution is investigated in the first part of the report...

  10. Croatian Capacity for Management of the NPP Krsko Radioactive Waste

    International Nuclear Information System (INIS)

    Levanat, Ivica; Lokner, Vladimir

    2014-01-01

    Together with Slovenia, Croatia is responsible for management of the NPP Krsko radioactive waste and spent fuel. So far, no firm agreement on specific solutions has been reached between the two countries. On the contrary, all activities related to revision and development of the joint Program of the NPP decommissioning and spent fuel and radioactive waste management were discontinued several years ago. Unless Slovenia and Croatia definitely agree on joint solutions in the meantime, Croatia will have to begin transfer of one half of the NPP Krsko spent fuel and radioactive waste into its territory in about nine years. Presently, however, Croatian capacities for such an undertaking are seriously inadequate in several respects, and they are not developing in any promising way. For no rational reason, this state of the Croatian capacities has been maintained (recently even deteriorating in some respects) for at least a decade, disregarding also for at least two years the explicit requirements of the EU Directive 2011/70/EURATOM aimed at establishing a Community framework for the responsible and safe management of spent fuel and radioactive waste. In fall of 2012, Fund for financing the NPP Krsko decommissioning and spent fuel and radioactive waste disposal was appointed as the Croatian expert organization for revision and development of the program of these same activities it had originally been supposed only to finance. In 2013 the Fund expanded its activities to a low-profile attempt at revitalization of the Croatian radioactive waste repository project, although the Fund is not yet properly capacitated for either of these tasks. The above is hardly in compliance with the Directive requirements, such as to establish 'a national legislative, regulatory and organisational framework' 'that allocates responsibility... between relevant competent bodies'. The lack of competent experts in the field appears to affect the quality of Croatian legislative

  11. [Office of Civilian Radioactive Waste Management] 1992 annual capacity report

    International Nuclear Information System (INIS)

    1993-03-01

    The Standard Contract for Disposal of Spent Nuclear Radioactive Waste (10 CFR Part 961) requires the Department of Energy (DOE) to issue an Annual Capacity Report (ACR) for planning purposes. This report is the fifth in the series published by DOE. In March 1993, DOE published the 1992 Acceptance Priority Ranking (APR) that established the order in which DOE will allocate projected acceptance capacity. As required by the Standard Contract, the acceptance priority ranking is based on the date the spent nuclear fuel (SNF) was permanently discharged, with the owners of the oldest SNF, on an industry-wide basis, given thehighest priority. The 1992 ACR applies the projected waste acceptance rates in Table 2.1 to the 1992 APR, resulting in individual allocations for the owners and generators of the SNF. These allocations art, listed in detail in the Appendix, and summarized in Table 3.1. The projected waste acceptance rates for SNF presented in Table 2.1 assume a site for a Monitored Retrievable Storage (MRS) facility will tic obtained; the facility will initiate operations in 1998; and the statutory linkages between the MRS facility and the repository set forth in the Nuclear Waste Policy Act of 1982, as amended (NWPA), will be modified. During the first ten years following projected commencement of Civilian Radioactive Waste Management System (CRWMS) operation, the total quantity of SNF that could be accepted is projected to be 8200 metric tons of uranium (MTU). This is consistent with the storage capacity licensing conditions imposed on an MRS facility by the NWPA. The annual acceptance rates provide an approximation of the system throughput and are subject to change as the program progresses

  12. Transition to New Refrigerants

    Science.gov (United States)

    Overview page provides information on the refrigerants that motor vehicle air conditioners have used over time, with information on environmental impacts, refrigerant fitting sizes, label colors, and alternatives to ozone-depleting substances.

  13. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1994-05-27

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  14. Cryogen-free dilution refrigerators

    International Nuclear Information System (INIS)

    Uhlig, K

    2012-01-01

    We review briefly our first cryogen-free dilution refrigerator (CF-DR) which was precooled by a GM cryocooler. We then show how today's dry DRs with pulse tube precooling have developed. A few examples of commercial DRs are explained and noteworthy features pointed out. Thereby we describe the general advantages of cryogen-free DRs, but also show where improvements are still desirable. At present, our dry DR has a base temperature of 10 mK and a cooling capacity of 700 μW at a mixing chamber temperature of 100 mK. In our cryostat, in most recent work, an additional refrigeration loop was added to the dilution circuit. This 4 He circuit has a lowest temperature of about 1 K and a refrigeration capacity of up to 100 mW at temperatures slightly above 1 K; the dilution circuit and the 4 He circuit can be run separately or together. The purpose of this additional loop is to increase the cooling capacity for experiments where the cooling power of the still of the DR is not sufficient to cool cold amplifiers and cables, e.g. in studies on superconducting quantum circuits or astrophysical applications.

  15. Cryogen-free dilution refrigerators

    Science.gov (United States)

    Uhlig, K.

    2012-12-01

    We review briefly our first cryogen-free dilution refrigerator (CF-DR) which was precooled by a GM cryocooler. We then show how today's dry DRs with pulse tube precooling have developed. A few examples of commercial DRs are explained and noteworthy features pointed out. Thereby we describe the general advantages of cryogen-free DRs, but also show where improvements are still desirable. At present, our dry DR has a base temperature of 10 mK and a cooling capacity of 700 μW at a mixing chamber temperature of 100 mK. In our cryostat, in most recent work, an additional refrigeration loop was added to the dilution circuit. This 4He circuit has a lowest temperature of about 1 K and a refrigeration capacity of up to 100 mW at temperatures slightly above 1 K; the dilution circuit and the 4He circuit can be run separately or together. The purpose of this additional loop is to increase the cooling capacity for experiments where the cooling power of the still of the DR is not sufficient to cool cold amplifiers and cables, e.g. in studies on superconducting quantum circuits or astrophysical applications.

  16. Theoretical study on a novel dual-nozzle ejector enhanced refrigeration cycle for household refrigerator-freezers

    International Nuclear Information System (INIS)

    Zhou, Mengliu; Wang, Xiao; Yu, Jianlin

    2013-01-01

    Highlights: • A novel dual-nozzle ejector enhanced refrigeration cycle is proposed. • The novel cycle is evaluated by using the developed mathematical model. • The results show the performances of the novel cycle could be significantly improved. • The novel cycle shows its promise in household refrigerator-freezers applications. - Abstract: In this study, a novel dual-nozzle ejector enhanced refrigeration cycle is presented for dual evaporator household refrigerator-freezers. The proposed ejector equipped with two nozzles can efficiently recover the expansion work from cycle throttling processes and enhance cycle performances. The performances of the novel cycle are evaluated by using the developed mathematical model, and then compared with that of the conventional ejector enhanced refrigeration cycle and basic vapor-compression refrigeration cycle. The simulation results show that for the given operating conditions, the coefficient of performance (COP) of the novel cycle using refrigerant R134a is improved by 22.9–50.8% compared with that of the basic vapor-compression refrigeration cycle, and the COP improvement is 10.5–30.8% larger than that of the conventional ejector enhanced refrigeration cycle. The further simulation results of the novel cycle using refrigerant R600a indicate that the cycle COP and volumetric refrigeration capacity could be significantly improved

  17. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1996-04-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates. Citations in this report are divided into the following topics: thermophysical properties; materials compatibility; lubricants and tribology; application data; safety; test and analysis methods; impacts; regulatory actions; substitute refrigerants; identification; absorption and adsorption; research programs; and miscellaneous documents. Information is also presented on ordering instructions for the computerized version.

  18. Managing Transboundary Crises : The Emergence of European Union Capacity

    NARCIS (Netherlands)

    Boin, Arjen; Rhinard, Mark; Ekengren, Magnus

    The European Union (EU) has modest but promising capacities to assist member states overwhelmed by disaster through its Civil Protection Mechanism. The EU also routinely sends civil and military missions to hotspots outside EU territory. But these capacities do not suffice in the face of

  19. Developments in magnetocaloric refrigeration

    International Nuclear Information System (INIS)

    Brueck, Ekkes

    2005-01-01

    Modern society relies on readily available refrigeration. Magnetic refrigeration has three prominent advantages compared with compressor-based refrigeration. First, there are no harmful gases involved; second, it may be built more compactly as the working material is a solid; and third, magnetic refrigerators generate much less noise. Recently a new class of magnetic refrigerant-materials for room-temperature applications was discovered. These new materials have important advantages over existing magnetic coolants: they exhibit a large magnetocaloric effect (MCE) in conjunction with a magnetic phase-transition of first order. This MCE is larger than that of Gd metal, which is used in the demonstration refrigerators built to explore the potential of this evolving technology. In the present review we compare the different materials considering both scientific aspects and industrial applicability. Because fundamental aspects of MCE are not so widely discussed, we also give some theoretical considerations. (topical review)

  20. The EPA-Wide Plan to Provide Solid Waste Management Capacity Assistance to Tribes

    Science.gov (United States)

    This Plan is a strategy for building tribal capacity to manage solid waste. The Plan promotes the development and implementation of integrated waste management plans and describes how EPA will prioritize its resources to maximize environmental benefits.

  1. Managing the Newsvendor Modeled Product System with Random Capacity and Capacity-Dependent Price

    Directory of Open Access Journals (Sweden)

    Qingying Li

    2015-01-01

    Full Text Available We consider a newsvendor modeled product system, where the firm provides products to the market. The supply capacity of the product is random, so the firm receives either the amount of order quantity or the realized capacity, whichever is smaller. The market price is capacity dependent. We consider two types of production cost structures: the procurement case and the in-house production case. The firm pays for the received quantity in the former case and for the ordered quantity in the latter case. We obtain the optimal order quantities for both cases. Comparing with the traditional newsvendor model, we find that the optimal order quantity in both the procurement case and the in-house production case are no greater than that in the traditional newsvendor model with a fixed selling price. We also find that the optimal order quantity for the procurement case is greater than that for the in-house production case. Numerical study is conducted to investigate the sensitivity of the optimal solution versus the distribution of the random capacity/demand.

  2. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1998-08-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  3. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1997-02-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  4. Exergy analysis of refrigerators for large scale cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Loehlein, K [Sulzer Cryogenics, Winterthur (Switzerland); Fukano, T [Nippon Sanso Corp., Kawasaki (Japan)

    1993-01-01

    Facilities with superconducting magnets require cooling capacity at different temperature levels and of different types (refrigeration or liquefaction). The bigger the demand for refrigeration, the more investment for improved efficiency of the refrigeration plant is justified and desired. Refrigeration cycles are built with discrete components like expansion turbines, cold compressors, etc. Therefore the exergetic efficiency for producing refrigeration on a distinct temperature level is significantly dependent on the 'thermodynamic arrangement' of these components. Among a variety of possibilities, limited by the range of applicability of the components, one has to choose the best design for higher efficiency on every level. Some influences are being quantified and aspects are given for a optimal integration of the refrigerator into the whole cooling system. (orig.).

  5. Integrated workforce capacity and inventory management under temporary labor supply uncertainty

    NARCIS (Netherlands)

    Pac, M.F.; Alp, O.; Tan, T.

    2007-01-01

    In a manufacturing environment with volatile demand, inventory management can be coupled with dynamic capacity adjustments for handling the fluctuations more effectively. In this study, we consider the problem of integrated capacity and inventory management under non-stationary stochastic demand and

  6. Integrated workforce capacity and inventory management under temporary labor supply uncertainty

    NARCIS (Netherlands)

    Pac, M.F.; Alp, O.; Tan, T.

    2009-01-01

    In a manufacturing environment with volatile demand, inventory management can be coupled with dynamic capacity adjustments for handling the fluctuations more effectively. In this study, we consider the problem of integrated capacity and inventory management under non-stationary stochastic demand and

  7. Cryogenic mixed refrigerant processes

    CERN Document Server

    Venkatarathnam, Gadhiraju

    2010-01-01

    Teaches the need for refrigerant mixtures, the type of mixtures that can be used for different refrigeration and liquefaction applications, the different processes that can be used and the methods to be adopted for choosing the components of a mixture and their concentration for different applications.

  8. Improvement of two-stage GM refrigerator performance using a hybrid regenerator

    International Nuclear Information System (INIS)

    Ke, G.; Makuuchi, H.; Hashimoto, T.; Onishi, A.; Li, R.; Satoh, T.; Kanazawa, Y.

    1994-01-01

    To improve the performance of two-stage GM refrigerators, a hybrid regenerator with magnetic materials of Er 3 Ni and ErNi 0.9 Co 0.1 was used in the 2nd stage regenerator because of its large heat exchange capacity. The largest refrigeration capacity achieved with the hybrid regenerator was 0.95W at helium liquefied temperature of 4.2K. This capacity is 15.9% greater than the 0.82W refrigerator with only Er 3 Ni as the 2nd regenerator material. Use of the hybrid regenerator not only increases the refrigeration capacity at 4.2K, but also allows the 4K GM refrigerator to be used with large 1st stage refrigeration capacity, thus making it more practical

  9. Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Vineyard, Edward Allan [ORNL

    2012-01-01

    Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; system performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.

  10. Refrigerants and environment

    Science.gov (United States)

    Tsvetkov, O. B.; Laptev, Yu A.

    2017-11-01

    The refrigeration and air-conditioning industries are important sectors of the economy and represents about 15 % of global electricity consumptions. The chlorofluorocarbons also called CFCs are a class of refrigerants containing the halogens chlorine and/or fluorine on a carbon skeleton. Because of their environmental impact the Montreal Protocol was negotiated in 1987 to limit the production of certain CFCs and hydrochlirofluorocarbons (HCFCs) in developed and developing countries. The halogenated refrigerants are depleting the ozone layer also major contribution to the greenhouse effect. To be acceptable as a refrigerant a fluid must satisfy a variety of thermodynamic criteria and should be environment friendly with zero Ozone Depletion Potential and low Global Warming Potential. The perspective of a future phase down of HFCs is considered in this report taking into account a strategy for the phase out of HCFCs and perspective of choosing of various refrigerant followed by safety issues.

  11. Applicability of ASST-A helium refrigeration system for JLab End Station Refrigerator

    Science.gov (United States)

    Hasan, N.; Knudsen, P.; Ganni, V.

    2017-12-01

    The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab’s four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab’s Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.

  12. Moroccan Coastal Management : Building Capacity to Adapt to ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Impacts from rising sea levels, coastal flooding and storm surges are becoming a challenging policy issue for planners, local authorities and stakeholders in areas such as Morocco's northeastern coast. This project will support capacity building and the development of tools and methods to underpin preparation for and ...

  13. Human resource capacity for information management in selected ...

    African Journals Online (AJOL)

    Results: it was established that capacity building was usually undertaken through on-job trainings i.e. 85.1% (103) health workers had on-job training on filling of data collection tools and only 10% (13) had received formal classroom training on the same. Further, only 9.1% (11) health workers had received information ...

  14. Expanding Integrated Pest Management Capacity: Rwanda Case Study

    Science.gov (United States)

    Baributsa, Dieudonne; Flores, Luis; Rukazambuga, Daniel; Wise, John C.

    2014-01-01

    Purpose: Rwanda is developing its agricultural capacity to meet the needs of national food security while addressing food demands and requirements of regional and international markets. The Rwanda Horticultural Export Standards Initiative was developed by the Ministry of Agriculture and Natural Resources in collaboration with Michigan State…

  15. Organizational collaborative capacity in fighting pandemic crises: a literature review from the public management perspective.

    Science.gov (United States)

    Lai, Allen Y

    2012-01-01

    Collaborative capacity serves for organizations as the capacity to collaborate with other network players. Organizational capacity matters as collaboration outcomes usually go beyond single-shot implementation efforts or a single-minded focus on either the vertical dimension of program or the horizontal component. This review article explores organizational collaborative capacities from the perspective of public management, in particular, network theory. By applying the 5 attributes of network theory-interdependence, membership, resources, information, and learning-to the explanation of collaborative capacity in fighting pandemic crises, I argue in some ways organizational collaborative capacity is very much like an organization in its own right. Studying collaborative capacity in the battle against pandemics facilitate our understanding of multisectoral collaboration in technical, political, and institutional dimensions, and greatly advances the richness of capacity vocabulary in pandemic response and preparedness.

  16. The Capacity Building in the Natural Disaster Management of Thailand

    OpenAIRE

    Eakarat Boonreang

    2015-01-01

    The past two decades, Thailand faced the natural disasters, for instance, Gay typhoon in 1989, tsunami in 2004, and huge flood in 2011. The disaster management in Thailand was improved both structure and mechanism for cope with the natural disaster since 2007. However, the natural disaster management in Thailand has various problems, for examples, cooperation between related an organizations have not unity, inadequate resources, the natural disaster management of public s...

  17. Office of Civilian Radioactive Waste Management: Annual capacity report

    International Nuclear Information System (INIS)

    1988-06-01

    The system configuration used as the basis for this year's report is the authorized system defined in the Mission Plan Amendment. It includes a Monitored Retrievable Storage (MRS) facility as an integral system component. The illustrative waste acceptance schedule for this WMS configuration reflects the amended first repository schedule and a proposed schedule for the MRS facility. This schedule provides only an approximation of when and how the system may operate and is subject to changes as recognized in the draft Mission Plan Amendment. During the first 10 years of WMS operation, the total quantity of spent fuel that could be accepted is projected to be 24,100 metric tons uranium (MTU). The allocation of acceptance rights is currently based on the projected annual capacity of the WMS to receive SNF and the age of permanently discharged spent fuel as determined from 1986 data provided by the Purchasers of waste disposal services on the 1987 Nuclear Fuel Data Form, RW-859. The allocations are based on assigning the highest priority to the oldest fuel on an industry-wide basis. The Annual Capacity Report (ACR) provides a discussion of the requirement for the ACR and the role it plays in DOE's interaction with the Purchasers in implementing the provisions of the Standard Disposal Contract. The currently projected annual acceptance capacity to be allocated and a discussion of some of the impacts the Nuclear Waste Policy Amendments Act of 1987 may have on the Purchasers, DOE, and the Contract are presented. The basis and procedure for allocating this capacity (acceptance rights) are discussed. The status of the ACR Issue Resolution Process and DOE responses to comments on the 1987 ACR are discussed. 7 refs

  18. Office of Civilian Radioactive Waste Management annual capacity report

    International Nuclear Information System (INIS)

    1991-12-01

    The Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (10 CFR Part 961) requires the Department of Energy (DOE) to issue an Annual Capacity Report (ACR) for planning purposes. This report is the fourth in the series published by DOE. In December 1991, the Department published the 1991 Acceptance Priority Ranking (APR) that established the order in which the Department will allocate acceptance capacity. As required by the Standard Contract, the priority ranking for acceptance capacity is based on the date the spent nuclear fuel (SNF) was permanently discharged, with the owners of the oldest SNF, on an industry-wide basis, given the highest priority. The 1991 ACR applies the waste acceptance rates in the 1991 APR, resulting in individual Purchaser allocations. These allocations are listed and summarized. The projected waste acceptance rates for SNF presented assume: a site for a Monitored Retrievable Storage (MRS) facility will be obtained and the facility will be obtained and the facility will initiate operations in 1998; and the statutory schedule linkages between the MRS facility and the repository set forth in the Nuclear Waste Policy of 1982, as amended (NWPA) will be modified

  19. Non-linear and adaptive control of a refrigeration system

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Larsen, Lars F. S.

    2011-01-01

    are capable of adapting to variety of systems. This paper proposes a novel method for superheat and capacity control of refrigeration systems; namely by controlling the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed......In a refrigeration process heat is absorbed in an evaporator by evaporating a flow of liquid refrigerant at low pressure and temperature. Controlling the evaporator inlet valve and the compressor in such a way that a high degree of liquid filling in the evaporator is obtained at all compressor...... capacities ensures a high energy efficiency. The level of liquid filling is indirectly measured by the superheat. Introduction of variable speed compressors and electronic expansion valves enables the use of more sophisticated control algorithms, giving a higher degree of performance and just as important...

  20. Building Perinatal Case Manager Capacity Using Quality Improvement

    OpenAIRE

    Fitzgerald, Elaine

    2015-01-01

    Improving breastfeeding rates among Black women is a potential strategy to address disparities in health outcomes that disproportionately impact Black women and children. This quality improvement (QI) initiative aimed to improve perinatal case manager knowledge and self-efficacy to promote breastfeeding among Black, low-income women who use services through Boston Healthy Start Initiative. QI methodology was used to develop and test a two-part strategy for perinatal case managers to promote a...

  1. Management model of productive capacity: integrating theory of constraints and the global operational efficiency index (IROG

    Directory of Open Access Journals (Sweden)

    Diego Augusto Pacheco

    2012-08-01

    Full Text Available This paper presents a model of management capacity in productive systems integrating the concepts of the Theory of Constraints and Total Productive Maintenance (TPM. The main objective of this study is to discuss and propose a model of management capacity, able to answer the following key questions: i capacity indicators which should be considered and how to measure them to measure the productive capacity of manufacturing systems? ii what is the real productive capacity of the system analyzed under a determined relationship between capacity and demand? The discussion of the proposed model is relevant because the definition of productive capacity system enables better management of resources and capabilities, improve production scheduling on the factory floor and meeting the demands imposed by the market. This paper presents the proposition of using the Operating Income Index Global (IROG with a different approach from traditional literature dealing with the theme, presented by Nakajima (1988. The results of this paper enable to develop a model to determine the capacity of the production system and the impact on the productive capacity of the entire system, not to consider the quality conformances that occur after the bottleneck resource of the production flow.

  2. Modelling refrigerant distribution in microchannel evaporators

    DEFF Research Database (Denmark)

    Brix, Wiebke; Kærn, Martin Ryhl; Elmegaard, Brian

    2009-01-01

    of the refrigerant distribution is carried out for two channels in parallel and for two different cases. In the first case maldistribution of the inlet quality into the channels is considered, and in the second case a non-uniform airflow on the secondary side is considered. In both cases the total mixed superheat...... out of the evaporator is kept constant. It is shown that the cooling capacity of the evaporator is reduced significantly, both in the case of unevenly distributed inlet quality and for the case of non-uniform airflow on the outside of the channels.......The effects of refrigerant maldistribution in parallel evaporator channels on the heat exchanger performance are investigated numerically. For this purpose a 1D steady state model of refrigerant R134a evaporating in a microchannel tube is built and validated against other evaporator models. A study...

  3. Designing a magnet for magnetic refrigeration

    DEFF Research Database (Denmark)

    Bjørk, Rasmus

    This thesis investigates the design and optimization of a permanent magnet assembly for use in a magnetic refrigeration device. The heart of magnetic refrigeration is the adiabatic temperature change in the magnetocaloric material which is caused by the magnetic field. In order to design an ideal...... magnet assembly the magnetocaloric materials and the refrigeration process itself and their properties and performance as a function of magnetic field are investigated. For the magnetocaloric materials it is the magnetization, specific heat capacity and adiabatic temperature that are investigated...... as a function of the magnetic field in order to learn the properties of the optimal magnet assembly. The performance of the AMR as a function of the synchronization and width of the magnetic field with respect to the AMR cycle, the ramp rate and maximum value of the magnetic field are investigated. Other...

  4. Comparing nurse managers and nurses' perceptions of nurses' self-leadership during capacity building.

    Science.gov (United States)

    Jooste, Karien; Cairns, Lindi

    2014-05-01

    This paper compares the perceptions of nurse managers and nurses about self-leadership of professional nurses while taking ownership of capacity building during unit management. The Nursing Strategy for South Africa states that the competency of nurses is dependent upon factors that lead to capacity building. A quantitative design was followed by conducting a survey. The target population included nurse managers and professional nurses working at an academic public hospital in the Gauteng Province of South Africa. The findings indicate shortcomings in relation to advising professional nurses about self-direction while taking ownership of their daily pressures and stresses associated with unit management. Professional nurses should develop their confidence by focusing on their self-leadership strengths when managing a unit. Recommendations are made to promote self-leadership while taking ownership of nurses during capacity building of unit management. © 2014 John Wiley & Sons Ltd.

  5. Report: EPA Needs an Agency-Wide Plan to Provide Tribal Solid Waste Management Capacity Assistance

    Science.gov (United States)

    Report #11-P-0171, March 21, 2011. EPA cannot determine whether its efforts are assisting tribal governments in developing the capacity to manage solid waste or reduce the risks of open dumps in Indian country.

  6. A participatory action research approach to strengthening health managers' capacity at district level in Eastern Uganda.

    Science.gov (United States)

    Tetui, Moses; Coe, Anna-Britt; Hurtig, Anna-Karin; Bennett, Sara; Kiwanuka, Suzanne N; George, Asha; Kiracho, Elizabeth Ekirapa

    2017-12-28

    Many approaches to improving health managers' capacity in poor countries, particularly those pursued by external agencies, employ non-participatory approaches and often seek to circumvent (rather than strengthen) weak public management structures. This limits opportunities for strengthening local health managers' capacity, improving resource utilisation and enhancing service delivery. This study explored the contribution of a participatory action research approach to strengthening health managers' capacity in Eastern Uganda. This was a qualitative study that used open-ended key informant interviews, combined with review of meeting minutes and observations to collect data. Both inductive and deductive thematic analysis was undertaken. The Competing Values Framework of organisational management functions guided the deductive process of analysis and the interpretation of the findings. The framework builds on four earlier models of management and regards them as complementary rather than conflicting, and identifies four managers' capacities (collaborate, create, compete and control) by categorising them along two axes, one contrasting flexibility versus control and the other internal versus external organisational focus. The findings indicate that the participatory action research approach enhanced health managers' capacity to collaborate with others, be creative, attain goals and review progress. The enablers included expanded interaction spaces, encouragement of flexibility, empowerment of local managers, and the promotion of reflection and accountability. Tension and conflict across different management functions was apparent; for example, while there was a need to collaborate, maintaining control over processes was also needed. These tensions meant that managers needed to learn to simultaneously draw upon and use different capacities as reflected by the Competing Values Framework in order to maximise their effectiveness. Improved health manager capacity is

  7. Quantum heat engines and refrigerators: continuous devices.

    Science.gov (United States)

    Kosloff, Ronnie; Levy, Amikam

    2014-01-01

    Quantum thermodynamics supplies a consistent description of quantum heat engines and refrigerators up to a single few-level system coupled to the environment. Once the environment is split into three (a hot, cold, and work reservoir), a heat engine can operate. The device converts the positive gain into power, with the gain obtained from population inversion between the components of the device. Reversing the operation transforms the device into a quantum refrigerator. The quantum tricycle, a device connected by three external leads to three heat reservoirs, is used as a template for engines and refrigerators. The equation of motion for the heat currents and power can be derived from first principles. Only a global description of the coupling of the device to the reservoirs is consistent with the first and second laws of thermodynamics. Optimization of the devices leads to a balanced set of parameters in which the couplings to the three reservoirs are of the same order and the external driving field is in resonance. When analyzing refrigerators, one needs to devote special attention to a dynamical version of the third law of thermodynamics. Bounds on the rate of cooling when Tc→0 are obtained by optimizing the cooling current. All refrigerators as Tc→0 show universal behavior. The dynamical version of the third law imposes restrictions on the scaling as Tc→0 of the relaxation rate γc and heat capacity cV of the cold bath.

  8. Assessing the components of adaptive capacity to improve conservation and management efforts under global change.

    Science.gov (United States)

    Nicotra, Adrienne B; Beever, Erik A; Robertson, Amanda L; Hofmann, Gretchen E; O'Leary, John

    2015-10-01

    Natural-resource managers and other conservation practitioners are under unprecedented pressure to categorize and quantify the vulnerability of natural systems based on assessment of the exposure, sensitivity, and adaptive capacity of species to climate change. Despite the urgent need for these assessments, neither the theoretical basis of adaptive capacity nor the practical issues underlying its quantification has been articulated in a manner that is directly applicable to natural-resource management. Both are critical for researchers, managers, and other conservation practitioners to develop reliable strategies for assessing adaptive capacity. Drawing from principles of classical and contemporary research and examples from terrestrial, marine, plant, and animal systems, we examined broadly the theory behind the concept of adaptive capacity. We then considered how interdisciplinary, trait- and triage-based approaches encompassing the oft-overlooked interactions among components of adaptive capacity can be used to identify species and populations likely to have higher (or lower) adaptive capacity. We identified the challenges and value of such endeavors and argue for a concerted interdisciplinary research approach that combines ecology, ecological genetics, and eco-physiology to reflect the interacting components of adaptive capacity. We aimed to provide a basis for constructive discussion between natural-resource managers and researchers, discussions urgently needed to identify research directions that will deliver answers to real-world questions facing resource managers, other conservation practitioners, and policy makers. Directing research to both seek general patterns and identify ways to facilitate adaptive capacity of key species and populations within species, will enable conservation ecologists and resource managers to maximize returns on research and management investment and arrive at novel and dynamic management and policy decisions. © 2015 Society for

  9. Assessing the components of adaptive capacity to improve conservation and management efforts under global change

    Science.gov (United States)

    Nicotra, Adrienne; Beever, Erik; Robertson, Amanda; Hofmann, Gretchen; O’Leary, John

    2015-01-01

    Natural-resource managers and other conservation practitioners are under unprecedented pressure to categorize and quantify the vulnerability of natural systems based on assessment of the exposure, sensitivity, and adaptive capacity of species to climate change. Despite the urgent need for these assessments, neither the theoretical basis of adaptive capacity nor the practical issues underlying its quantification has been articulated in a manner that is directly applicable to natural-resource management. Both are critical for researchers, managers, and other conservation practitioners to develop reliable strategies for assessing adaptive capacity. Drawing from principles of classical and contemporary research and examples from terrestrial, marine, plant, and animal systems, we examined broadly the theory behind the concept of adaptive capacity. We then considered how interdisciplinary, trait- and triage-based approaches encompassing the oft-overlooked interactions among components of adaptive capacity can be used to identify species and populations likely to have higher (or lower) adaptive capacity. We identified the challenges and value of such endeavors and argue for a concerted interdisciplinary research approach that combines ecology, ecological genetics, and eco-physiology to reflect the interacting components of adaptive capacity. We aimed to provide a basis for constructive discussion between natural-resource managers and researchers, discussions urgently needed to identify research directions that will deliver answers to real-world questions facing resource managers, other conservation practitioners, and policy makers. Directing research to both seek general patterns and identify ways to facilitate adaptive capacity of key species and populations within species, will enable conservation ecologists and resource managers to maximize returns on research and management investment and arrive at novel and dynamic management and policy decisions.

  10. OPTIMAL SYSNTHESIS PROCESSES OF LOW-TEMPERATURE CONDENSATION ASSOCIATED OIL GAS PLANT REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    O. Ostapenko

    2015-10-01

    Full Text Available Design of modern high-efficient systems is a key priority for the Energy Sector of Ukraine. The cooling technological streams of gas and oil refineries, including air coolers, water cooling and refrigeration systems for specific refrigerants are the objectives of the present study. Improvement of the refrigeration unit with refrigerant separation into fractions is mandatory in order to increase cooling capacity, lowering the boiling point of coolant and increasing the coefficient of target hydrocarbons extraction from the associated gas flow. In this paper it is shown that cooling temperature plays significant role in low-temperature condensation process. Two operation modes for refrigeration unit were proposed: permanent, in which the concentration of the refrigerant mixture does not change and dynamic, in which the concentration of refrigerant mixtures depends on the ambient temperature. Based on the analysis of exergy losses the optimal concentration of refrigerant mixtures propane/ethane for both modes of operation of the refrigeration unit has been determined. On the basis of the conducted pinch-analysis the modification of refrigeration unit with refrigerant separation into fractions was developed. Additional recuperative heat exchangers for utilization heat were added to the scheme. Several important measures to increase the mass flow rate of refrigerant through the second section of the refrigeration centrifugal compressor from 22.5 to 25 kg/s without violating the agreed operational mode of the compressor sections were implemented.

  11. Load Management of Data Centers as Regulation Capacity in Denmark

    DEFF Research Database (Denmark)

    Clausen, Anders; Ghatikar, Girish; Jørgensen, Bo Nørregaard

    2014-01-01

    are of special interest as they account for 500 GWh of consumption in Denmark or nearly 2% of the total electricity consumption. This paper performs an analysis on load management capabilities of data centers in Denmark based on the experiences in the U.S. We characterize the load management capabilities...... for transmission system operators and distribution system operators and balance errors in forecasts made by balance responsible parties. By enabling the demand-side to adapt consumption to match power generation, we can address this in a cost-effective and environmental sound way. In this context, data centers...... of the data centers based on their types, technology, and their application as grid management resources. Further, we identify demand-side entry barriers towards market participation. Our findings suggest that groups of data centers can offer dynamic load flexibility as virtual power plants, and thereby...

  12. Public Refrigerated Warehouses

    Data.gov (United States)

    Department of Homeland Security — The International Association of Refrigerated Warehouses (IARW) came into existence in 1891 when a number of conventional warehousemen took on the demands of storing...

  13. Thermoacoustic engines and refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.

    1996-12-31

    This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

  14. Refrigerated display cabinets; Butikskyla

    Energy Technology Data Exchange (ETDEWEB)

    Fahlen, Per

    2000-07-01

    This report summarizes experience from SP research and assignments regarding refrigerated transport and storage of food, mainly in the retail sector. It presents the fundamentals of heat and mass transfer in display cabinets with special focus on indirect systems and secondary refrigerants. Moreover, the report includes a brief account of basic food hygiene and the related regulations. The material has been compiled for educational purposes in the Masters program at Chalmers Technical University.

  15. High temperature refrigerator

    International Nuclear Information System (INIS)

    Steyert, W.A. Jr.

    1978-01-01

    A high temperature magnetic refrigerator is described which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle the working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot

  16. Refrigeration systems and applications

    CERN Document Server

    Dincer, Ibrahim

    2010-01-01

    Refrigeration Systems and Applications, 2nd edition offers a comprehensive treatise that addresses real-life technical and operational problems, enabling the reader to gain an understanding of the fundamental principles and the practical applications of refrigeration technology. New and unique analysis techniques (including exergy as a potential tool), models, correlations, procedures and applications are covered, and recent developments in the field are included - many of which are taken from the author's own research activities in this area. The book also includes so

  17. Optimised battery capacity utilisation within battery management systems

    NARCIS (Netherlands)

    Wilkins, S.; Rosca, B. (Bogdan); Jacob, J.; Hoedmaekers, E.

    2015-01-01

    Battery Management Systems (BMSs) play a key role in the performance of both hybrid and fully electric vehicles. Typically, the role of the BMS is to help maintain safety, performance, and overall efficiency of the battery pack. One important aspect of its operation is the estimation of the state of

  18. Building a Sustainable Project Management Capacity in Cyprus

    Science.gov (United States)

    Kelly, Steven J.; Esque, Timm J.; Novak, M. Mari; Cermakova, Anna

    2012-01-01

    The performance-driven project management program examined in this article was funded to support a variety of technical assistance efforts designed to strengthen the performance of small and medium enterprises in the Turkish Cypriot community in Cyprus. The customized program combined progressive workshops with hands-on and distance coaching by…

  19. Management capacity to promote nurse workplace health and safety.

    Science.gov (United States)

    Fang, Yaxuan; McDonald, Tracey

    2018-04-01

    To investigate regarding workplace health and safety factors, and to identify strategies to preserve and promote a healthy nursing workplace. Data collected using the Delphi technique with input from 41 key informants across four participant categories drawn from a Chinese university and four hospitals were thematically analysed. Most respondents agreed on the importance of nurses' health and safety, and that nurse managers should act to protect nurses, but not enough on workplace safety. Hospital policies, staff disempowerment, workload and workplace conflicts are major obstacles. The reality of Chinese nurses' workplaces is that health and safety risks abound and relate to socio-cultural expectations of women. Self-management of risks is neccessary, gaps exist in understanding of workplace risks among different nursing groups and their perceptions of the professional status, and the value of nurses' contribution to ongoing risks in the hospital workplace. The Chinese hospital system must make these changes to produce a safer working environment for nurses. This research, based in China, presents an instructive tale for all countries that need support on the types and amounts of management for nurses working at the clinical interface, and on the consequences of management neglect of relevant policies and procedures. © 2017 John Wiley & Sons Ltd.

  20. Building Organizational Capacity: Strategic Management in Higher Education

    Science.gov (United States)

    Toma, J. Douglas

    2010-01-01

    Every university or college president envisions bold initiatives--big projects intended to change the nature of an institution with significant implications across all sectors. How can leaders and senior managers charged with implementing reforms effectively frame their work and anticipate potential pitfalls? No organization can maximize its…

  1. Workshops capacity building for agricultural water demand management; final report

    NARCIS (Netherlands)

    Vehmeijer, P.W.; Wolters, W.

    2004-01-01

    Agricultural Water Demand Management (AWDM) is at the core of the Water for Food Programme launched as a result of a pledge by the Netherlands' Minister for Agriculture at the 2nd World Water Forum in March 2000, The Hague. One of the projects that was started after the March 2000 pledge was

  2. Capacity waste management at automotive industry in India: A Six Sigma observation

    Directory of Open Access Journals (Sweden)

    Rajeev Rathi

    2015-11-01

    Full Text Available The companies in present challenging world are trying hard to improve their productivity and capacity utilization levels without actually increasing the sale price of their products. In India, in today combative world, the majority of automotive manufacturing industries are scuffling hard with their low levels of productivity. Possibly there are different reasons for this and capacity waste or under-utilization of productive capacity in industries appears to be one of the prime reasons. As corrective action, the present study makes an effort to check the efficacy of Six Sigma approach to improve capacity waste management. With a case study, through successful execution of Define phase, the study confirms the perception of Six Sigma for capacity waste management in Indian automotive industry.

  3. Synergy of fuzzy AHP and Six Sigma for capacity waste management in Indian automotive industry

    Directory of Open Access Journals (Sweden)

    Rajeev Rathi

    2015-07-01

    Full Text Available Capacity waste management is highly essential because under utilization of capacity is often referred to as a major reason for lower productivity among industries around the world. For better estimation of capacity and its utilization and then for its improved management; newer techniques are being devised in industrial sector. The current case of capacity waste problem has been taken up as a Six Sigma project, where we try to analyze critical factors responsible for the capacity waste. Decisions on critical factor selection in analysis phase of Six Sigma are always very crucial. The paper discusses an approach for selection of capacity waste factors at an automotive industry using fuzzy logic based AHP method. The fuzzy AHP is a well recognized tool to undertake the fuzziness of the data involved in choosing the preferences of the different decision variables engaged in the process of capacity waste factors selection. In this context, we have explored six crucial parameters for selection of capacity waste factors. Final ranking is calculated through priority vector thus obtained and it is seen that conveyor malfunction is found to be the key factor for capacity waste among all alternatives at the selected site.

  4. Capacity building in solid waste management in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    McBean, E. A.; Del Rosso, E.; Schoemaker, H.

    2002-03-01

    To assist in climate change protection and to improve solid waste management practices, a project in being undertaken in Tucuman, Argentina's fifth largest city, with funding from the Climate Change Early Action Fund, the Government of Canada and from Conestoga-Rovers and Associates. The demonstration project covers the wastes for purposes of accelerating landfill gas production, thereby improving options for utilizing landfill gas as an energy source, and providing climate change protection by transforming methane to carbon dioxide, which is substantially less powerful as a global warming gas. Prior to the project, refuse was dumped directly into an uncontrolled dump or the adjacent Sali River, or burnt, releasing noxious gases to the atmosphere. The primary objective of the energy cell project involved the collection of refuse and placement in energy cells. The energy cells are operated as bioreactors to accelerate the generation of landfill gas. The project included placement of a comprehensive bottom liner system, leachate collection, preparation of the refuse, a leachate recirculation system, a gas collection system, and a flexible top membrane liner. The emphasis of the energy cell project is to demonstrate the opportunities available, which could influence the viability of energy recovery and possible greenhouse gas credits. After only a few months of direct learning from the energy cell project, solid waste management in Tucuman has been decisively reversed. There is no longer any uncontrolled dumping and implementation of a modern solid waste management system is well under way.

  5. Governance and Management of the Nexus: Structures and Institutional Capacities

    Directory of Open Access Journals (Sweden)

    Snorek Julie

    2015-01-01

    Full Text Available Sustaining the water-energy-food nexus for the future requires new governance approaches and joint management across sectors. The challenges to the implementation of the nexus are many, but not insurmountable. These include trade-offs between sectors, difficulties of communication across the science-policy interface, the emergence of new vulnerabilities resulting from implementation of policies, and the perception of high social and economic costs. In the context of the Sustainability in the W-E-F Nexus conference May 19-20, 2014, the session on ‘Governance and Management of the Nexus: Structures and Institutional Capacities’ discussed these problems as well as tools and solutions to nexus management. The session demonstrated three key findings: 1. Trade-offs in the Water-Energy-Food Nexus should be expanded to include the varied and shifting social and power relations; 2. Sharing knowledge between users and policy makers promotes collective learning and science-policy-stakeholder communication; and 3. Removing subsidies or seeking the ‘right price’ for domestic resources vis à vis international markets is not always useful; rather the first imperative is to gauge current and future costs at the national scale.

  6. Production capacity of metallurgical enterprises in modular structure of management accounting

    Directory of Open Access Journals (Sweden)

    Zambrzhitskaia E.S.

    2017-01-01

    Full Text Available This article is the result of constant research in development of management accounting at modern Russian metallurgical works. The required steps of renovation are presented for the modernization of management accounting system in the case of production capacity. The necessary factors with defined values are systematized for modern enterprises. The main ones are those which are regulate the measure of the payload of production capacity. For the purposes of effective management accounting at metallurgical enterprises it is suggested to use the system of controlling parameters which were formulated for the enterprise for production of rolls. Later in the article the necessary changes to the modular structure of management accounting business are described and expanded with new structural element – “Management of production capacity”. The suggested methodical approach will allow the company management to respond quickly to rapidly changing external environment and, as a consequence, to make effective management decisions.

  7. Hospital capacity and management preparedness for pandemic influenza in Victoria.

    Science.gov (United States)

    Dewar, Ben; Barr, Ian; Robinson, Priscilla

    2014-04-01

    This study was designed to investigate acute hospital pandemic influenza preparedness in Victoria, Australia, particularly focussing on planning and management efforts. A prospective study was conducted by questionnaire and semi-structured interview of health managers across the Victorian hospital system from July to October 2011. Participants with responsibility for emergency management, planning and operations were selected from every hospital in Victoria with an emergency department to complete a questionnaire (response rate 22/43 = 51%). Each respondent was invited to participate in a phone-based semi-structured interview (response rate 11/22 = 50%). Rural/regional hospitals demonstrated higher levels of clinical (86%) and non-clinical (86%) staff contingency planning than metropolitan hospitals (60% and 40% respectively). Pandemic plans were not being sufficiently tested in exercises or drills, which is likely to undermine their effectiveness. All respondents reported hand hygiene and standard precautions programs in place, although only one-third (33%) of metropolitan respondents and no rural/regional respondents reported being able to meet patient needs with high levels of staff absenteeism. Almost half Victoria's healthcare workers were unvaccinated against influenza. Hospitals across Victoria demonstrated different levels of influenza pandemic preparedness and planning. If a more severe influenza pandemic than that of 2009 arose, Victorian hospitals would struggle with workforce and infrastructure problems, particularly in rural/regional areas. Staff absenteeism threatens to undermine hospital pandemic responses. Various strategies, including education and communication, should be included with in-service training to provide staff with confidence in their ability to work safely during a future pandemic. © 2014 The Authors. ANZJPH © 2014 Public Health Association of Australia.

  8. Working with capacity limitations: operations management in critical care.

    Science.gov (United States)

    Terwiesch, Christian; Diwas, K C; Kahn, Jeremy M

    2011-08-16

    As your hospital's ICU director, you are approached by the hospital's administration to help solve ongoing problems with ICU bed availability. The ICU seems to be constantly full, and trauma patients in the emergency department sometimes wait up to 24 hours before receiving a bed. Additionally, the cardiac surgeons were forced to cancel several elective coronary-artery bypass graft cases because there was not a bed available for postoperative recovery. The hospital administrators ask whether you can decrease your ICU length of stay, and wonder whether they should expand the ICU to include more beds For help in understanding and optimizing your ICU's throughput, you seek out the operations management researchers at your university.

  9. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

    1993-04-30

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

  10. Cryogenic forced convection refrigerating system

    International Nuclear Information System (INIS)

    Klee, D.J.

    1988-01-01

    This patent describes the method of refrigerating products by contact with a refrigerating gas which comprises introducing product into a refrigeration zone, contacting the product with the refrigerating gas for a sufficient time to refrigerate it to the appropriate extent and removing the refrigerated product. The improvement for producing the refrigeration gas from a liquid cryogen such that essentially all of the liquid cryogen is fully vaporized before contacting the product comprises: (a) introducing the liquid cryogen, selected from the group consisting of liquid air and liquid nitrogen, at elevated pressure into an ejector as the motive fluid to accelerate a portion of a warm refrigerating gas through the ejector while mixing the cryogen and gas to effect complete vaporization of the liquid cryogen and substantial cooling of the portion of the refrigerating gas resulting in a cold discharge gas which is above the liquefaction temperature of the cryogen; (b) introducing the cold discharge gas into a forced circulation pathway of refrigerating gas and producing a cold refrigerating gas which contacts and refrigerates product and is then at least partially recirculated; (c) sensing the temperature of the refrigerating gas in the forced circulation pathway and controlling the introduction of liquid cryogen with regard to the sensed temperature to maintain the temperature of the discharge gas above the liquefacton temperature of the cryogen utilized

  11. Load leveling on industrial refrigeration systems

    Science.gov (United States)

    Bierenbaum, H. S.; Kraus, A. D.

    1982-01-01

    A computer model was constructed of a brewery with a 2000 horsepower compressor/refrigeration system. The various conservation and load management options were simulated using the validated model. The savings available for implementing the most promising options were verified by trials in the brewery. Result show that an optimized methodology for implementing load leveling and energy conservation consisted of: (1) adjusting (or tuning) refrigeration systems controller variables to minimize unnecessary compressor starts, (2) The primary refrigeration system operating parameters, compressor suction pressure, and discharge pressure are carefully controlled (modulated) to satisfy product quality constraints (as well as in-process material cooling rates and temperature levels) and energy evaluating the energy cost savings associated with reject heat recovery, and (4) a decision is made to implement the reject heat recovery system based on a cost/benefits analysis.

  12. Optimal Energy Consumption in Refrigeration Systems - Modelling and Non-Convex Optimisation

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Larsen, Lars F. S.; Skovrup, Morten J.

    2012-01-01

    Supermarket refrigeration consumes substantial amounts of energy. However, due to the thermal capacity of the refrigerated goods, parts of the cooling capacity delivered can be shifted in time without deteriorating the food quality. In this study, we develop a realistic model for the energy...... consumption in super market refrigeration systems. This model is used in a Nonlinear Model Predictive Controller (NMPC) to minimise the energy used by operation of a supermarket refrigeration system. The model is non-convex and we develop a computational efficient algorithm tailored to this problem...

  13. Indirect refrigeration systems with natural refrigerants

    DEFF Research Database (Denmark)

    Knudsen, Hans Jørgen Høgaard; Christensen, Kim Gardø; Jensen, Per Henrik

    1998-01-01

    Heat transfer for boiling and condensing carbon dioxide has been investigated.Heat transfer for carbon dioxide evaporating inside pipe has been measured and compared with Shah's correlation. The measured heat transfer coefficient is much higher than the value determined with the correlation.A shell......-and-tube heat exchanger with carbon dioxide on the shell side and flow ice inside the tubes has been used to investigate the heat transfer for condensing carbon dioxide.At leats is mentioned results obtained with a frozen food display case using carbone dioxide as refrigerant....

  14. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1992-11-09

    The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

  15. Managing Creativity for Absorptive Capacity: The NIH Syndrome and the Implementation of Open Innovation Business Model

    DEFF Research Database (Denmark)

    Cokpekin, Özge

    The benefits of the open innovation business model and the absorptive capacity necessary to acquire and utilize external knowledge have been discussed extensively. An emerging literature stream has identified certain intra-organizational antecedents of absorptive capacity. However how firms...... recognize potentially valuable external knowledge to be able to start the knowledge absorption process has not been discussed. This paper suggests creativity management and argues that stimulating meaningfully novel behavior positively influences the recognition ability and the communication it enhances...

  16. 24 CFR 570.205 - Eligible planning, urban environmental design and policy-planning-management-capacity building...

    Science.gov (United States)

    2010-04-01

    ... environmental design and policy-planning-management-capacity building activities. 570.205 Section 570.205..., urban environmental design and policy-planning-management-capacity building activities. (a) Planning... known or suspected environmental contamination. (5) [Reserved] (6) Policy—planning—management—capacity...

  17. A Tool and Process that Facilitate Community Capacity Building and Social Learning for Natural Resource Management

    Directory of Open Access Journals (Sweden)

    Christopher M. Raymond

    2013-03-01

    Full Text Available This study presents a self-assessment tool and process that facilitate community capacity building and social learning for natural resource management. The tool and process provide opportunities for rural landholders and project teams both to self-assess their capacity to plan and deliver natural resource management (NRM programs and to reflect on their capacities relative to other organizations and institutions that operate in their region. We first outline the tool and process and then present a critical review of the pilot in the South Australian Arid Lands NRM region, South Australia. Results indicate that participants representing local, organizational, and institutional tiers of government were able to arrive at a group consensus position on the strength, importance, and confidence of a variety of capacities for NRM categorized broadly as human, social, physical, and financial. During the process, participants learned a lot about their current capacity as well as capacity needs. Broad conclusions are discussed with reference to the iterative process for assessing and reflecting on community capacity.

  18. Refrigeration a history

    CERN Document Server

    Gantz, Carroll

    2015-01-01

    For thousands of years, humans coped with heat by harvesting and storing natural ice and devising natural cooling systems that utilized ventilation and evaporation. By the mid 1800s, people began developing huge refrigeration machines to manufacture ice. By the early 1900s, engineers developed electric domestic refrigerators, which by 1927 were affordable convenient household appliances. By then, an increasingly sophisticated public demanded more modern-looking appliances than engineers could produce, and a new breed of designers entered the manufacturing world to provide them. During the Depr

  19. Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator

    International Nuclear Information System (INIS)

    Wongwises, Somchai; Chimres, Nares

    2005-01-01

    This work presents an experimental study on the application of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator. The hydrocarbons investigated are propane (R290), butane (R600) and isobutane (R600a). A refrigerator designed to work with HFC-134a with a gross capacity of 239 l is used in the experiment. The consumed energy, compressor power and refrigerant temperature and pressure at the inlet and outlet of the compressor are recorded and analysed as well as the distributions of temperature at various positions in the refrigerator. The refrigerant mixtures used are divided into three groups: the mixture of three hydrocarbons, the mixture of two hydrocarbons and the mixture of two hydrocarbons and HFC-134a. The experiments are conducted with the refrigerants under the same no load condition at a surrounding temperature of 25 deg. C. The results show that propane/butane 60%/40% is the most appropriate alternative refrigerant to HFC-134a

  20. Prediction of thermophysical properties of mixed refrigerants using artificial neural network

    International Nuclear Information System (INIS)

    Sencan, Arzu; Koese, Ismail Ilke; Selbas, Resat

    2011-01-01

    The determination of thermophysical properties of the refrigerants is very important for thermodynamic analysis of vapor compression refrigeration systems. In this paper, an artificial neural network (ANN) is proposed to determine properties as heat conduction coefficient, dynamic viscosity, kinematic viscosity, thermal diffusivity, density, specific heat capacity of refrigerants. Five alternative refrigerants are considered: R413A, R417A, R422A, R422D and R423A. The training and validation were performed with good accuracy. The thermophysical properties of the refrigerants are formulated using artificial neural network (ANN) methodology. Liquid and vapor thermophysical properties of refrigerants with new formulation obtained from ANN can be easily estimated. The method proposed offers more flexibility and therefore thermodynamic analysis of vapor compression refrigeration systems is fairly simplified.

  1. 46 CFR 151.40-11 - Refrigeration systems.

    Science.gov (United States)

    2010-10-01

    ... compressors shall be such that the required cooling capacity of the system is maintained with one compressor inoperative. Portions of the system other than the compressors need not have standby capacity. ... 46 Shipping 5 2010-10-01 2010-10-01 false Refrigeration systems. 151.40-11 Section 151.40-11...

  2. Refrigeration Playbook: Natural Refrigerants; Selecting and Designing Energy-Efficient Commercial Refrigeration Systems That Use Low Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Caleb [CTA Architects Engineers, Boise, ID (United States); Reis, Chuck [CTA Architects Engineers, Boise, ID (United States); Nelson, Eric [CTA Architects Engineers, Boise, ID (United States); Armer, James [CTA Architects Engineers, Boise, ID (United States); Arthur, Rob [CTA Architects Engineers, Boise, ID (United States); Heath, Richard [CTA Architects Engineers, Boise, ID (United States); Rono, James [CTA Architects Engineers, Boise, ID (United States); Hirsch, Adam [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Doebber, Ian [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    This report provides guidance for selecting and designing energy efficient commercial refrigeration systems using low global warming potential refrigerants. Refrigeration systems are generally the largest energy end use in a supermarket type building, often accounting for more than half of a building's energy consumption.

  3. Designing a magnet for magnetic refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Bjoerk, R

    2010-03-15

    This thesis investigates the design and optimization of a permanent magnet assembly for use in a magnetic refrigeration device. The heart of magnetic refrigeration is the adiabatic temperature change in the magnetocaloric material which is caused by the magnetic field. In order to design an ideal magnet assembly the magnetocaloric materials and the refrigeration process itself and their properties and performance as a function of magnetic field are investigated. For the magnetocaloric materials it is the magnetization, specific heat capacity and adiabatic temperature that are investigated as functions of the magnetic field. Following this the process utilized by a magnetic refrigerator to provide cooling is investigated using a publicly available one dimensional numerical model. This process is called active magnetic regeneration (AMR). The aim is to determine the performance of the AMR as a function of the magnetic field in order to learn the properties of the optimal magnet assembly. The performance of the AMR as a function of the synchronization and width of the magnetic field with respect to the AMR cycle, the ramp rate and maximum value of the magnetic field are investigated. Other published magnet designs used in magnetic refrigeration devices are also evaluated, using a figure of merit based on the properties of the investigated magnetocaloric materials, to learn the properties of the best magnet designs to date. Following this investigation the Halbach cylinder, which is a hollow permanent magnet cylinder with a rotating remanent flux density, is investigated in detail as it forms the basis of many magnet designs used in magnetic refrigeration. Here the optimal dimensions of a Halbach cylinder, as well as analytical calculations of the magnetic field for a Halbach cylinder of infinite length, are presented. Once it has been determined which properties are desirable for a magnet used in magnetic refrigeration the design of a new magnet is described. This is

  4. Portable refrigerant charge meter and method for determining the actual refrigerant charge in HVAC systems

    Science.gov (United States)

    Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.

    2017-08-08

    A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.

  5. Farmers' management capacities as a success factor in agriculture: A review

    Directory of Open Access Journals (Sweden)

    Vukelić Nataša

    2014-01-01

    Full Text Available Farms operating under more or less similar environmental and socio-economic conditions often reflect significant differences in production and economic results they achieve. Such differences are most commonly attributed to: biological factors, the level of specialization, the intensity of production, the size of farms and/or implemented production practice, etc. It is considered that the differences in achieved results, that is, the success of a farm can be, to a large extent, explained by variations in farmers' management capacities. Management capacities can be defined as possession of appropriate personal characteristics and capabilities of farmers (managers to cope with specific problems and opportunities at the right time and in the right way. With the changes taking place within the modern agricultural production, it is becoming more and more difficult to maintain competitive advantages, thus the farmers are progressively confronted with the requirements for certain management capacities which will enable them to take advantage of the existing conditions in the best possible way, i.e. to choose and implement the optimal production practice. As the management capacities are rarely explicitly defined and quantified, particularly when it comes to agricultural producers, the aim of this study is to provide a review of the previous research in this field while highlighting the significance of these issues.

  6. Solar Powered Refrigeration System

    Science.gov (United States)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  7. Helium refrigerator for 'SULTAN'

    International Nuclear Information System (INIS)

    Arpagaus, M.; Erlach, H.; Quack, H.

    1984-01-01

    The authors describe the helium refrigerator designed for the SULTAN test facility. SULTAN (Supraleiter-Testanlage) is intended to serve for the developments and testing of high field superconducting magnets. These magnets are needed mainly for future applications in nuclear fusion. (Auth.)

  8. Helium dilution refrigerator

    International Nuclear Information System (INIS)

    1973-01-01

    A new system of continuous heat exchange for a helium dilution refrigerator is proposed. The 3 He effluent tube is concurrent with the affluent mixed helium tube in a vertical downward direction. Heat exchange efficiency is enhanced by placing in series a number of elements with an enlarged surface area

  9. The estimation of energy efficiency for hybrid refrigeration system

    International Nuclear Information System (INIS)

    Gazda, Wiesław; Kozioł, Joachim

    2013-01-01

    Highlights: ► We present the experimental setup and the model of the hybrid cooling system. ► We examine impact of the operating parameters of the hybrid cooling system on the energy efficiency indicators. ► A comparison of the final and the primary energy use for a combination of the cooling systems is carried out. ► We explain the relationship between the COP and PER values for the analysed cooling systems. -- Abstract: The concept of the air blast-cryogenic freezing method (ABCF) is based on an innovative hybrid refrigeration system with one common cooling space. The hybrid cooling system consists of a vapor compression refrigeration system and a cryogenic refrigeration system. The prototype experimental setup for this method on the laboratory scale is discussed. The application of the results of experimental investigations and the theoretical–empirical model makes it possible to calculate the cooling capacity as well as the final and primary energy use in the hybrid system. The energetic analysis has been carried out for the operating modes of the refrigerating systems for the required temperatures inside the cooling chamber of −5 °C, −10 °C and −15 °C. For the estimation of the energy efficiency the coefficient of performance COP and the primary energy ratio PER for the hybrid refrigeration system are proposed. A comparison of these coefficients for the vapor compression refrigeration and the cryogenic refrigeration system has also been presented.

  10. The state of human dimensions capacity for natural resource management: needs, knowledge, and resources

    Science.gov (United States)

    Sexton, Natalie R.; Leong, Kirsten M.; Milley, Brad J.; Clarke, Melinda M.; Teel, Tara L.; Chase, Mark A.; Dietsch, Alia M.

    2013-01-01

    The social sciences have become increasingly important in understanding natural resource management contexts and audiences, and are essential in design and delivery of effective and durable management strategies. Yet many agencies and organizations do not have the necessary resource management. We draw on the textbook definition of HD: how and why people value natural resources, what benefits people seek and derive from those resources, and how people affect and are affected by those resources and their management (Decker, Brown, and Seimer 2001). Clearly articulating how HD information can be used and integrated into natural resource management planning and decision-making is an important challenge faced by the HD field. To address this challenge, we formed a collaborative team to explore the issue of HD capacity-building for natural resource organizations and to advance the HD field. We define HD capacity as activities, efforts, and resources that enhance the ability of HD researchers and practitioners and natural managers and decision-makers to understand and address the social aspects of conservation.Specifically, we sought to examine current barriers to integration of HD into natural resource management, knowledge needed to improve HD capacity, and existing HD tools, resources, and training opportunities. We conducted a needs assessment of HD experts and practitioners, developed a framework for considering HD activities that can contribute both directly and indirectly throughout any phase of an adaptive management cycle, and held a workshop to review preliminary findings and gather additional input through breakout group discussions. This paper provides highlights from our collaborative initiative to help frame and inform future HD capacity-building efforts and natural resource organizations and also provides a list of existing human dimensions tools and resources.

  11. Capacity-building for health research in developing countries: a manager's approach

    Directory of Open Access Journals (Sweden)

    Franklin White

    2002-09-01

    Full Text Available Research may be viewed as rigorous inquiry to advance knowledge and improve practices. An international commission has argued that strengthening research capacity is one of the most powerful, cost-effective, and sustainable means of advancing health and development. However, the global effort to promote research in developing countries has been mostly policy driven, and largely at the initiative of donor agencies based in developed countries. This policy approach, although essential, both contrasts with and is complementary to that of research managers, who must build capacity "from the ground up" in a variety of health service settings within countries and with differing mandates, resources, and constraints. In health organizations the concept of research is broad, and practices vary widely. However, building research capacity is not altogether different from building other kinds of organizational capacity, and it involves two major dimensions: strategic and operational. In organizations in the health field, if reference to research is not in the mission statement, then developing a relevant research capacity is made vastly more difficult. Research capacities that take years to develop can be easily damaged through inadequate support, poor management, or other negative influences associated with both internal and external environments. This paper draws from key international research policy documents and observations on the behavior of research and donor agencies in relation to developing countries. It examines capacity-building primarily as a challenge for research managers, realities underlying operational effectiveness and efficiency, approaches to resource mobilization, and the need for marketing the research enterprise. Selected examples from South Asia and Latin America and the Caribbean are presented.

  12. How Employees' Perception of Information Technology Application and Their Knowledge Management Capacity Influence Organisational Performance

    Science.gov (United States)

    Kuo, Yen-Ku; Ye, Kung-Don

    2010-01-01

    This study investigates how workers' gender, work experience, designated division, and appointment affect (i) their perception of information technology (IT) within the organisation, (ii) their self-perceived capacity in knowledge management (KM), and (iii) their perception of organisational performance (OP). Furthermore, the study also examines…

  13. Constrained capacity management and cost minimisation of EV-charging in a parking garage

    NARCIS (Netherlands)

    Kamphuis, I.G.; Macdougall, P.; Veen, W. van der; Bakker, E.; Velde, J. van de

    2013-01-01

    Apart from the optimal real-time electricity price to buy the electricity, the optimal, time dependent, capacity contracted with the DSO is of crucial importance for concerted charging of electric vehicles in a parking garage. The battery management system, on its turn, imposes constraints on the

  14. RAILWAY INFRASTRUCTURE CAPACITY MANAGEMENT FOR AD-HOC TRAINS ON THE SŽDC NETWORK

    Directory of Open Access Journals (Sweden)

    Petr Nachtigall

    2016-09-01

    Full Text Available The paper describes basic principles of ad-hoc routes assignment. Each carrier has its own interface called information system KADR with SŽDC for capacity requests management. The paper describes all steps which must be done before train departure.

  15. Building Human Resources Management Capacity for University Research: The Case at Four Leading Vietnamese Universities

    Science.gov (United States)

    Nguyen, T. L.

    2016-01-01

    At research-intensive universities, building human resources management (HRM) capacity has become a key approach to enhancing a university's research performance. However, despite aspiring to become a research-intensive university, many teaching-intensive universities in developing countries may not have created effective research-promoted HRM…

  16. Elements for harnessing participatory action research to strengthen health managers' capacity: a critical interpretative synthesis.

    Science.gov (United States)

    Tetui, Moses; Zulu, Joseph Mumba; Hurtig, Anna-Karin; Ekirapa-Kiracho, Elizabeth; Kiwanuka, Suzanne N; Coe, Anna-Britt

    2018-04-19

    Health managers play a key role in ensuring that health services are responsive to the needs of the population. Participatory action research (PAR) is one of the approaches that have been used to strengthen managers' capacity. However, collated knowledge on elements for harnessing PAR to strengthen managers' capacity is missing. This paper bridges this gap by reviewing existing literature on the subject matter. A critical interpretive synthesis method was used to interrogate eight selected articles. These articles reported the use of PAR to strengthen health managers' capacity. The critical interpretive synthesis method's approach to analysis guided the synthesis. Here, the authors interpretively made connections and linkages between different elements identified in the literature. Finally, the Atun et al. (Heal Pol Plann, 25:104-111, 2010) framework on integration was used to model the elements synthesised in the literature into five main domains. Five elements with intricate bi-directional interactions were identified in the literature reviewed. These included a shared purpose, skilled facilitation and psychological safety, activity integration into organisational procedures, organisational support, and external supportive monitoring. A shared purpose of the managers' capacity strengthening initiative created commitment and motivation to learn. This purpose was built upon a set of facilitation skills that included promoting participation, self-efficacy and reflection, thereby creating a safe psychological space within which the managers interacted and learnt from each other and their actions. Additionally, an integrated intervention strengthened local capacity and harnessed organisational support for learning. Finally, supportive monitoring from external partners, such as researchers, ensured quality, building of local capacity and professional safety networks essential for continued learning. The five elements identified in this synthesis provide a basis upon

  17. Data mining techniques for thermophysical properties of refrigerants

    International Nuclear Information System (INIS)

    Kuecueksille, Ecir Ugur; Selbas, Resat; Sencan, Arzu

    2009-01-01

    This study presents ten modeling techniques within data mining process for the prediction of thermophysical properties of refrigerants (R134a, R404a, R407c and R410a). These are linear regression (LR), multi layer perception (MLP), pace regression (PR), simple linear regression (SLR), sequential minimal optimization (SMO), KStar, additive regression (AR), M5 model tree, decision table (DT), M5'Rules models. Relations depending on temperature and pressure were carried out for the determination of thermophysical properties as the specific heat capacity, viscosity, heat conduction coefficient, density of the refrigerants. Obtained model results for every refrigerant were compared and the best model was investigated. Results indicate that use of derived formulations from these techniques will facilitate design and optimize of heat exchangers which is component of especially vapor compression refrigeration system

  18. Synchronous temperature rate control for refrigeration with reduced energy consumption

    Science.gov (United States)

    Gomes, Alberto Regio; Keres, Stephen L.; Kuehl, Steven J.; Litch, Andrew D.; Richmond, Peter J.; Wu, Guolian

    2015-09-22

    Methods of operation for refrigerator appliance configurations with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper, and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The methods may include synchronizing alternating cycles of cooling each compartment to a temperature approximately equal to the compartment set point temperature by operation of the compressor, fans, damper and/or valve system. The methods may also include controlling the cooling rate in one or both compartments. Refrigeration compartment cooling may begin at an interval before or after when the freezer compartment reaches its lower threshold temperature. Freezer compartment cooling may begin at an interval before or after when the freezer compartment reaches its upper threshold temperature.

  19. Power Consumption in Refrigeration Systems - Modeling for Optimization

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Larsen, Lars F. S.; Skovrup, Morten Juel

    2011-01-01

    Refrigeration systems consume a substantial amount of energy. Taking for instance supermarket refrigeration systems as an example they can account for up to 50−80% of the total energy consumption in the supermarket. Due to the thermal capacity made up by the refrigerated goods in the system...... there is a possibility for optimizing the power consumption by utilizing load shifting strategies. This paper describes the dynamics and the modeling of a vapor compression refrigeration system needed for sufficiently realistic estimation of the power consumption and its minimization. This leads to a non-convex function...... with possibly multiple extrema. Such a function can not directly be optimized by standard methods and a qualitative analysis of the system’s constraints is presented. The description of power consumption contains nonlinear terms which are approximated by linear functions in the control variables and the error...

  20. Thermal investigations of a room temperature magnetic refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Smaili, Arezki; Chiba, Younes [Ecole Nationale Polytechnique d' Alger (Algeria)], email: arezki.smaili@enp.edu.dz

    2011-07-01

    Magnetic refrigeration is a concept based on the magnetocaloric effect that some materials exhibit when the external magnetic field changes. The aim of this paper is to assess the performance of a numerical model in predicting parameters of an active magnetic regenerator refrigerator. Numerical simulations were conducted to perform a thermal analysis on an active magnetic regenerator refrigerator operating near room temperature with and without applied cooling load. Curves of temperature span, cooling capacity and thermal efficiency as functions of the operating conditions were drawn and are presented in this paper. Results showed that at fixed frequency Ql versus mf has an optimum and COP was increased with cycle frequency values. This study demonstrated that the proposed numerical model could be used to predict parameters of an active magnetic regenerator refrigerator as it provides consistent results.

  1. Synchronous temperature rate control for refrigeration with reduced energy consumption

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Alberto Regio; Keres, Stephen L.; Kuehl, Steven J.; Litch, Andrew D.; Richmond, Peter J.; Wu, Guolian

    2017-11-07

    Methods of operation for refrigerator appliance configurations with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper, and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The methods may include synchronizing alternating cycles of cooling each compartment to a temperature approximately equal to the compartment set point temperature by operation of the compressor, fans, damper and/or valve system. The methods may also include controlling the cooling rate in one or both compartments. Refrigeration compartment cooling may begin at an interval before or after when the freezer compartment reaches its lower threshold temperature. Freezer compartment cooling may begin at an interval before or after when the freezer compartment reaches its upper threshold temperature.

  2. Helium refrigeration system for BNL colliding beam accelerator

    International Nuclear Information System (INIS)

    Brown, D.P.; Farah, Y.; Gibbs, R.J.; Schlafke, A.P.; Schneider, W.J.; Sondericker, J.H.; Wu, K.C.

    1983-01-01

    A Helium Refrigeration System which will supply the cooling required for the Colliding Beam Accelerator at Brookhaven National Laboratory is under construction. Testing of the compressor system is scheduled for late 1983 and will be followed by refrigerator acceptance tests in 1984. The refrigerator has a design capacity of 24.8 kW at a temperature level near 4K while simultaneously producing 55 kW for heat shield loads at 55K. When completed, the helium refrigerator will be the world's largest. Twenty-five oil-injected screw compressors with an installed total of 23,250 horsepower will supply the gas required. One of the unique features of the cycle is the application of three centrifugal compressors used at liquid helium temperature to produce the low temperatures (2.5K) and high flow rates (4154 g/s) required for this service

  3. Chilling Prospect: Climate Change Effects of Mismanaged Refrigerants in China.

    Science.gov (United States)

    Duan, Huabo; Miller, T Reed; Liu, Gang; Zeng, Xianlai; Yu, Keli; Huang, Qifei; Zuo, Jian; Qin, Yufei; Li, Jinhui

    2018-06-05

    The global community has responded to the dual threats of ozone depletion and climate change from refrigerant emissions (e.g., chlorofluorocarbons, CFCs, and hydrofluorocarbons, HFCs) in refrigerators and air conditioners (RACs) by agreeing to phase out the production of the most damaging chemicals and replacing them with substitutes. Since these refrigerants are "banked" in products during their service life, they will continue to impact our environment for decades to come if they are released due to mismanagement at the end of life. Addressing such long-term impacts of refrigerants requires a dynamic understanding of the RACs' life cycle, which was largely overlooked in previous studies. Based on field surveys and a dynamic model, we reveal the lingering ozone depletion potential (ODP) and significant global warming potential (GWP) of scrap refrigerants in China, the world's largest producer (62%) and consumer (46%) of RACs in 2015, which comes almost entirely from air conditioners rather than refrigerators. If the use and waste management of RACs continue with the current trend, the total GWP of scrap refrigerants in China will peak by 2025 at a level of 135.2 ± 18.9 Mt CO 2 e (equal to approximately 1.2% ± 0.2% of China's total greenhouse gas emissions or the national total of either The Netherlands and Czech Republic in 2015). Our results imply an urgent need for improving the recycling and waste management of RACs in China.

  4. Global capacity, potentials and trends of solid waste research and management.

    Science.gov (United States)

    Nwachukwu, Michael A; Ronald, Mersky; Feng, Huan

    2017-09-01

    In this study, United States, China, India, United Kingdom, Nigeria, Egypt, Brazil, Italy, Germany, Taiwan, Australia, Canada and Mexico were selected to represent the global community. This enabled an overview of solid waste management worldwide and between developed and developing countries. These are countries that feature most in the International Conference on Solid Waste Technology and Management (ICSW) over the past 20 years. A total of 1452 articles directly on solid waste management and technology were reviewed and credited to their original country of research. Results show significant solid waste research potentials globally, with the United States leading by 373 articles, followed by India with 230 articles. The rest of the countries are ranked in the order of: UK > Taiwan > Brazil > Nigeria > Italy > Japan > China > Canada > Germany >Mexico > Egypt > Australia. Global capacity in solid waste management options is in the order of: Waste characterisation-management > waste biotech/composting > waste to landfill > waste recovery/reduction > waste in construction > waste recycling > waste treatment-reuse-storage > waste to energy > waste dumping > waste education/public participation/policy. It is observed that the solid waste research potential is not a measure of solid waste management capacity. The results show more significant research impacts on solid waste management in developed countries than in developing countries where economy, technology and society factors are not strong. This article is targeted to motivate similar study in each country, using solid waste research articles from other streamed databases to measure research impacts on solid waste management.

  5. An Assessment of Institutional Capacity for Integrated Landscape Management in Eastern Cameroon.

    Science.gov (United States)

    Brown, H Carolyn Peach

    2018-07-01

    Landscape approaches have become prominent in efforts to address issues of conservation and development through bringing together different actors and sectors, to reconcile diverse land uses, and promote synergies. Some have suggested that integrated landscape management approaches are consistent with the goals of REDD+ and offer a strategy to address multiple goals of climate change mitigation, biodiversity conservation, maintenance of ecosystem services, and socio-economic development. Institutional or governance arrangements have been shown to be a critical component in influencing outcomes in landscapes. Using diverse methodologies, this study investigated the capacity of institutions to support the planning, implementation, and resource mobilization needed to integrate climate change mitigation, conservation, and livelihood goals in a forest mosaic landscape in East Cameroon. Results showed that diverse institutions are present in the landscape, including institutions of relevant government agencies, local government, local non-government, the private sector, and hybrid institutions of conservation, development and research institutions. However, the overall institutional capacity for integrated landscape planning and management in the study area is limited, although some institutions exhibit increased capacity in some areas over others. Multiple strategies can be employed to build the necessary human, financial, and leadership capacity, and facilitate the institutional planning and coordination that is foundational to multi-stakeholder landscape governance. Given the complexity of integrating climate change mitigation, conservation and livelihood goals in a landscape, building such institutional capacity is a long term endeavour that requires sustained effort and ongoing financial, technical and human resource support.

  6. Adaptive Superheat Control of a Refrigeration Plant using Backstepping

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2008-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The new idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. This gives a highly nonlinear transfer operator from compressor speed input to the superheat output....... A new low order nonlinear model of the evaporator is developed and used in a backstepping design of an adaptive nonlinear controller.  The stability of the proposed method is validated theoretically by Lyapunov analysis and experimental results shows the performance of the system for a wide range...

  7. Capacity building for tropical coastal ecosystems management using a dynamic teaching model

    DEFF Research Database (Denmark)

    Lindberg, Annika Büchert; Nielsen, Thomas; Macintosh, Donald

    2008-01-01

    This learning opportunity illustrates effective capacity building through a dynamic teaching model that involves you and gives you personal experiences. The teaching model is easy to adapt to local environments and the learning opportunity is relevant to everyone working in coastal natural resource...... in combining knowledge and methods and applying these in a real life situation. Objectives: The participants will apply the acquired knowledge of ecosystems and project management tools when describing ecosystem services and when planning a project The participants will act as different stakeholders during...... the role play and hereby gain experience from a situation mimicking real life project situation.; The participants will experience how dynamic teaching can improve capacity building....

  8. A risk management approach to double-shell tank waste volume versus storage capacity

    International Nuclear Information System (INIS)

    Coles, G.A.; Thurkow, T.J.; Fritz, R.L.; Nuhlestein, L.O.; Allen, M.R.; Stuart, R.J.

    1996-01-01

    A risk-based assessment of the overall waste volume versus double-shell tank storage capacity was conducted to develop fallback positions for projections where the waste volume was at a high risk of exceeding capacity. This study was initiated to provide that assessment. A working simulation model was the primary deliverable of this study. The model validates the approach and demonstrates that simulation analysis can provide a method of tracking uncertainties in available data, assessing probabilities, and serves as a tool to be used by management to determine the consequences of various off-normal occurrences

  9. A risk management approach to double-shell tank waste volume versus storage capacity

    Energy Technology Data Exchange (ETDEWEB)

    Coles, G.A. [Westinghouse Hanford Co., Richland, WA (United States); Thurkow, T.J.; Fritz, R.L.; Nuhlestein, L.O.; Allen, M.R.; Stuart, R.J. [ARES Corp. (United States)

    1996-01-01

    A risk-based assessment of the overall waste volume versus double-shell tank storage capacity was conducted to develop fallback positions for projections where the waste volume was at a high risk of exceeding capacity. This study was initiated to provide that assessment. A working simulation model was the primary deliverable of this study. The model validates the approach and demonstrates that simulation analysis can provide a method of tracking uncertainties in available data, assessing probabilities, and serves as a tool to be used by management to determine the consequences of various off-normal occurrences.

  10. Superfluid thermodynamic cycle refrigerator

    Science.gov (United States)

    Swift, Gregory W.; Kotsubo, Vincent Y.

    1992-01-01

    A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of .sup.3 He in a single phase .sup.3 He-.sup.4 He solution. The .sup.3 He in superfluid .sup.4 He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid .sup.3 He at an initial concentration in superfluid .sup.4 He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of .sup.4 He while restricting passage of .sup.3 He. The .sup.3 He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

  11. Flammability Indices for Refrigerants

    Science.gov (United States)

    Kataoka, Osami

    This paper introduces a new index to classify flammable refrigerants. A question on flammability indices that ASHRAE employs arose from combustion test results of R152a and ammonia. Conventional methods of not only ASHRAE but also ISO and Japanese High-pressure gas safety law to classify the flammability of refrigerants are evaluated to show why these methods conflict with the test results. The key finding of this paper is that the ratio of stoichiometric concentration to LFL concentration (R factor) represents the test results most precisely. In addition, it has excellent correlation with other flammability parameters such as flame speed and pressure rise coefficient. Classification according to this index gives reasonable flammability order of substances including ammonia, R152a and carbon monoxide. Theoretical background why this index gives good correlation is also discussed as well as the insufficient part of this method.

  12. Analysis of Refrigeration Equipment in School Nutrition Programs in the USDA/FNS Southwest Region

    Science.gov (United States)

    Webb, Virginia Susan

    2012-01-01

    Equipment to store foods at proper temperatures is critical to serving safe and nutritious meals in schools yet little is known about the amount or the adequacy of refrigerated storage in school nutrition programs. The purposes of this study were to identify the types and capacity of refrigeration equipment used in schools, determine the perceived…

  13. Preventing refrigerated foodstuffs in supermarkets from being discarded on hot days by mpc

    DEFF Research Database (Denmark)

    Cai, Junping; Stoustrup, Jakob; Jørgensen, John Bagterp

    2008-01-01

    This paper presents an optimization strategy for supermarket refrigeration systems. It deals with one special condition when the extremely high outdoor temperature causes the compressor to saturate, and work at its maximum capacity. In a traditional control, refrigerated foodstuffs inside display...

  14. Quantum-Circuit Refrigerator

    Science.gov (United States)

    MöTtöNen, Mikko; Tan, Kuan Y.; Masuda, Shumpei; Partanen, Matti; Lake, Russell E.; Govenius, Joonas; Silveri, Matti; Grabert, Hermann

    Quantum technology holds great potential in providing revolutionizing practical applications. However, fast and precise cooling of the functional quantum degrees of freedom on demand remains a major challenge in many solid-state implementations, such as superconducting circuits. We demonstrate direct cooling of a superconducting resonator mode using voltage-controllable quantum tunneling of electrons in a nanoscale refrigerator. In our first experiments on this type of a quantum-circuit refrigerator, we measure the drop in the mode temperature by electron thermometry at a resistor which is coupled to the resonator mode through ohmic losses. To eliminate unwanted dissipation, we remove the probe resistor and directly observe the power spectrum of the resonator output in agreement with the so-called P(E) theory. We also demonstrate in microwave reflection experiments that the internal quality factor of the resonator can be tuned by orders of magnitude. In the future, our refrigerator can be integrated with different quantum electric devices, potentially enhancing their performance. For example, it may prove useful in the initialization of superconducting quantum bits and in dissipation-assisted quantum annealing. We acknowledge European Research Council Grant SINGLEOUT (278117) and QUESS (681311) for funding.

  15. International cryospheric science capacity building and its role in policy and management

    Science.gov (United States)

    Wilson, A. M.; Armstrong, R. L.; Armstrong, B. R.; Barrett, A. P.; Brodzik, M. J.; Fetterer, F. M.; Fluri, J. L.; Hill, A. F.; Kayastha, R. B.; Khalsa, S. J. S.; Khan, A. L.; Miller, H. A.; Minbaeva, C.; Racoviteanu, A.; Raup, B. H.; Rittger, K.

    2017-12-01

    The USAID-funded Contribution to High Asia Runoff from Ice and Snow (CHARIS) project has operated since 2012 with dual goals of research and capacity building. The scientific goal is to quantify snowmelt and ice melt and is tackled in tandem with capacity building activities for partner institutions in eight countries across High Asia. We held project workshops covering topics such as snow and glacier melt modeling, remote sensing of snow and ice, hydrochemistry-based hydrograph separation, and data management. CHARIS also facilitated the start of the first glacier mass balance program in Afghanistan, the first water chemistry laboratory in Bhutan, and supported eight students from four countries in earning Masters of Science by Research in Glaciology degrees from Kathmandu University. Capacity building outcomes are tracked through surveys and interviews with project partners. This feedback, both quantitative and qualitative, improves our understanding of how skills fostered by CHARIS are translated into different workplace contexts and in different political settings. Through this feedback, we document how CHARIS collaborations promote analytical skill development and provide the benefit of improved communication among colleagues across borders in a region where resource management requires a trans-boundary approach. Additionally, we are gathering feedback from partners on ways their hydrology and glaciology research is translated to the policy and management realms. Partners anecdotally report a range of policy relationships, especially with respect to management strategies for water intensive developments such as hydropower and mining. Here we present findings from these surveys, which will guide future development-oriented, science-driven resource management projects. Such endeavors must be tailored to large regional differences in expertise, capacities, policy settings, and research infrastructures, and CHARIS demonstrates ways this can be done effectively.

  16. Management of marine cage aquaculture. Environmental carrying capacity method based on dry feed conversion rate.

    Science.gov (United States)

    Cai, Huiwen; Sun, Yinglan

    2007-11-01

    Marine cage aquaculture produces a large amount of waste that is released directly into the environment. To effectively manage the mariculture environment, it is important to determine the carrying capacity of an aquaculture area. In many Asian countries trash fish is dominantly used in marine cage aquaculture, which contains more water than pellet feed. The traditional nutrient loading analysis is for pellet feed not for trash fish feed. So, a more critical analysis is necessary in trash fish feed culturing areas. Corresponding to FCR (feed conversion rate), dry feed conversion rate (DFCR) was used to analyze the nutrient loadings from marine cage aquaculture where trash fish is used. Based on the hydrodynamic model and the mass transport model in Xiangshan Harbor, the relationship between the water quality and the waste discharged from cage aquaculture has been determined. The environmental carrying capacity of the aquaculture sea area was calculated by applying the models noted above. Nitrogen and phosphorus are the water quality parameters considered in this study. The simulated results show that the maximum nitrogen and phosphorus concentrations were 0.216 mg/L and 0.039 mg/L, respectively. In most of the sea area, the nutrient concentrations were higher than the water quality standard. The calculated environmental carrying capacity of nitrogen and phosphorus in Xiangshan Harbor were 1,107.37 t/yr and 134.35 t/yr, respectively. The waste generated from cage culturing in 2000 has already exceeded the environmental carrying capacity. Unconsumed feed has been identified as the most important origin of all pollutants in cage culturing systems. It suggests the importance of increasing the feed utilization and improving the feed composition on the basis of nutrient requirement. For the sustainable development of the aquaculture industry, it is an effective management measure to keep the stocking density and pollution loadings below the environmental carrying

  17. 24 CFR 1003.205 - Eligible planning, urban environmental design and policy-planning-management-capacity building...

    Science.gov (United States)

    2010-04-01

    ... environmental design and policy-planning-management-capacity building activities. 1003.205 Section 1003.205... planning, urban environmental design and policy-planning-management-capacity building activities. (a... plans, general environmental studies, and strategies and action programs to implement plans, including...

  18. 42 CFR 137.21 - How does an Indian Tribe demonstrate financial stability and financial management capacity?

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false How does an Indian Tribe demonstrate financial stability and financial management capacity? 137.21 Section 137.21 Public Health PUBLIC HEALTH SERVICE... How does an Indian Tribe demonstrate financial stability and financial management capacity? The Indian...

  19. An integrated approach to inventory and flexible capacity management subject to fixed costs and non-stationary stochastic demand

    NARCIS (Netherlands)

    Tan, T.; Alp, O.

    2009-01-01

    In a manufacturing system with flexible capacity, inventory management can be coupled with capacity management in order to handle fluctuations in demand more effectively. Typical examples include the effective use of temporary workforce and overtime production. In this paper, we discuss an

  20. Building leadership capacity in advanced nurse practitioners - the role of organisational management.

    Science.gov (United States)

    Elliott, Naomi

    2017-01-01

    To highlight the organisation-level management's role in building leadership capacity in advanced nurse practitioners and the need for appropriate supports to increase their becoming leaders. Little is published about the role of organisation-level management in building leadership capacity and in developing the next generation of nurse leaders. In times of economic constraint, organisations need to focus their efforts on targeted leadership initiatives. Advanced nurse practitioners are ideally positioned to act as leaders both within and beyond the health care organisation. From the available research evidence, several support structures and mechanisms are identified as enablers for advanced nurse practitioners to enact their leadership role. Health care organisations need to include building leadership capacity as a priority in their strategic plan and take action to build-up the level of advanced nurse practitioner leadership. Nurse executives have a vital role in influencing the organisation's strategic plan and making a business case for prioritising leadership capacity building within advanced nurse practitioners. A challenge for nurse executives faced with competing service and leadership development demands, involves strategic decision-making regarding whether the advanced nurse practitioner's role is limited to service delivery or its potential in leading health care reforms is realised. © 2016 John Wiley & Sons Ltd.

  1. Being everything to anyone: Applicability of thermoacoustic technology in the commercial refrigeration market

    Science.gov (United States)

    Poese, Matthew E.; Smith, Robert W. M.; Garrett, Steven L.

    2005-09-01

    This talk will compare electrodynamically driven thermoacoustic refrigeration technology to some common implementations of low-lift vapor-compression technology. A rudimentary explanation of vapor-compression refrigeration will be presented along with some of the implementation problems faced by refrigeration engineers using compressor-based systems. These problems include oil management, compressor slugging, refrigerant leaks and the environmental impact of refrigerants. Recently, the method of evaluating this environmental impact has been codified to include the direct effects of the refrigerants on global warming as well as the so-called ``indirect'' warming impact of the carbon dioxide released during the generation (at the power plant) of the electrical power consumed by the refrigeration equipment. It is issues like these that generate commercial interest in an alternative refrigeration technology. However, the requirements of a candidate technology for adoption in a mature and risk-averse commercial refrigeration industry are as hard to divine as they are to meet. Also mentioned will be the state of other alternative refrigeration technologies like free-piston Stirling, thermoelectric and magnetocaloric as well as progress using vapor compression technology with alternative refrigerants like hydrocarbons and carbon dioxide.

  2. Academic and research capacity development in Earth observation for environmental management

    International Nuclear Information System (INIS)

    Cassells, Gemma; Woodhouse, Iain H; Patenaude, Genevieve; Tembo, Mavuto

    2011-01-01

    Sustainable environmental management is one of the key development goals of the 21st century. The importance of Earth observation (EO) for addressing current environmental problems is well recognized. Most developing countries are highly susceptible to environmental degradation; however, the capacity to monitor these changes is predominantly located in the developed world. Decades of aid and effort have been invested in capacity development (CD) with the goal of ensuring sustainable development. Academics, given their level of freedom and their wider interest in teaching and knowledge transfer, are ideally placed to act as catalyst for capacity building. In this letter, we make a novel investigation into the extent to which the EO academic research community is engaged in capacity development. Using the Web of Knowledge publication database (http://wok.mimas.ac.uk), we examined the geographical distribution of published EO related research (a) by country as object of research and (b) by authors' country of affiliation. Our results show that, while a significant proportion of EO research (44%) has developing countries as their object of research, less than 3% of publications have authors working in, or affiliated to, a developing country (excluding China, India and Brazil, which not only are countries in transition, but also have well established EO capacity). These patterns appear consistent over the past 20 years. Despite the wide awareness of the importance of CD, we show that significant progress on this front is required. We therefore propose a number of recommendations and best practices to ease collaboration and open access.

  3. TIGER-NET – enabling an Earth Observation capacity for Integrated Water Resource Management in Africa

    DEFF Research Database (Denmark)

    Walli, A.; Tøttrup, C.; Naeimi, V.

    As part of the TIGER initiative [1] the TIGER-NET project aims to support the assessment and monitoring of water resources from watershed to transboundary basin level delivering indispensable information for Integrated Water Resource Management in Africa through: 1. Development of an open......-source Water Observation and Information Systems (WOIS) for monitoring, assessing and inventorying water resources in a cost-effective manner; 2. Capacity building and training of African water authorities and technical centers to fully exploit the increasing observation capacity offered by current...... and upcoming generations of satellites, including the Sentinel missions. Dedicated application case studies have been developed and demonstrated covering all EO products required by and developed with the participating African water authorities for their water resource management tasks, such as water reservoir...

  4. Addressing challenges for future strategic-level emergency management: reframing, networking, and capacity-building.

    Science.gov (United States)

    Bosomworth, Karyn; Owen, Christine; Curnin, Steven

    2017-04-01

    The mounting frequency and intensity of natural hazards, alongside growing interdependencies between social-technical and ecological systems, are placing increased pressure on emergency management. This is particularly true at the strategic level of emergency management, which involves planning for and managing non-routine, high-consequence events. Drawing on the literature, a survey, and interviews and workshops with Australia's senior emergency managers, this paper presents an analysis of five core challenges that these pressures are creating for strategic-level emergency management. It argues that emphasising 'emergency management' as a primary adaptation strategy is a retrograde step that ignores the importance of addressing socio-political drivers of vulnerabilities. Three key suggestions are presented that could assist the country's strategic-level emergency management in tackling these challenges: (i) reframe emergency management as a component of disaster risk reduction rather than them being one and the same; (ii) adopt a network governance approach; and (iii) further develop the capacities of strategic-level emergency managers. © 2017 The Author(s). Disasters © Overseas Development Institute, 2017.

  5. Limited options for low-global-warming-potential refrigerants

    Science.gov (United States)

    McLinden, Mark O.; Brown, J. Steven; Brignoli, Riccardo; Kazakov, Andrei F.; Domanski, Piotr A.

    2017-02-01

    Hydrofluorocarbons, currently used as refrigerants in air-conditioning systems, are potent greenhouse gases, and their contribution to climate change is projected to increase. Future use of the hydrofluorocarbons will be phased down and, thus replacement fluids must be found. Here we show that only a few pure fluids possess the combination of chemical, environmental, thermodynamic, and safety properties necessary for a refrigerant and that these fluids are at least slightly flammable. We search for replacements by applying screening criteria to a comprehensive chemical database. For the fluids passing the thermodynamic and environmental screens (critical temperature and global warming potential), we simulate performance in small air-conditioning systems, including optimization of the heat exchangers. We show that the efficiency-versus-capacity trade-off that exists in an ideal analysis disappears when a more realistic system is considered. The maximum efficiency occurs at a relatively high volumetric refrigeration capacity, but there are few fluids in this range.

  6. Water infiltration capacity under different land uses and agricultural management practices

    OpenAIRE

    Lizandra Poeta Teixeira; Vander Kaufmann; Adilson Pinheiro

    2009-01-01

    Knowledge of physical and hydraulic properties of soil is important for the appropriate use and management of soil, and for the understanding of dynamic movement process of water and solutes. This study aims to determine the soil infiltration capacity of the Concordia Experimental Basin, located in the municipality of Lontras in Santa Catarina state. The infiltration tests were performed with the concentric ring infiltrometer, with a diameter of 25 and 50 cm on twenty sampling points showing ...

  7. THERMODYNAMIC PROPERTIES OF SELECTED HFC REFRIGERANTS

    Science.gov (United States)

    Hydrofluorocarbon (HFC) refrigerants are possible alternatives to replace ozone-depleting chlorofluorocarbon and hydrochlorofluorocarbon (HCFC) refrigerants. The flammability of a proposed new refrigerant is a major consideration in assessing its utility for a particular applicat...

  8. Thermodynamic analysis of hydrocarbon refrigerants in a sub-cooling refrigeration system

    Directory of Open Access Journals (Sweden)

    BUKOLA O. BOLAJI

    2013-06-01

    Full Text Available In this study, the performance simulation of some hydrocarbon refrigerants (R290, R600 and R600a as alternatives to R134a in refrigeration system with sub-cooling is conducted by thermodynamic calculation of performance parameters using the REFPROP software. The results obtained showed that the saturated vapour pressure and temperature characteristic profiles for R600 and R600a are very close to that of R134a. The three hydrocarbon refrigerants exhibited very high refrigerating effect and condenser duty than R134a. The best of these parameters was obtained using R600. The discharge temperatures obtained using R600 and R600a were low, while that of R290 was very much higher. The highest coefficient of performance (COP and relative capacity index were obtained using R600. Average COPs of R600 and R600a are 4.6 and 2.2% higher than that of R134a, respectively. The performances of R600 and R600a in system were better than those of R134a and R290. The best performance was obtained using R600 in the system.

  9. ‘Prevention is better than cure’: Assessing Ghana’s preparedness (capacity for disaster management

    Directory of Open Access Journals (Sweden)

    Martin Oteng-Ababio

    2013-04-01

    Full Text Available This article examines and contributes to the debate on Ghana’s capacity and preparedness to respond to disasters and build safer communities. Having witnessed a series of catastrophic events in recent times, many have questioned the capacity of the National Disaster Management Organisation, an institution mandated to manage disasters in Ghana and whose operations have historically been shaped by external pressures, particularly the populist tendencies of the Provisional National Defense Council government in the 1980s. Analysing the results from the fieldwork and placing them in the context of contemporary disaster management strategies, this article gives an overview of Ghana’s preparedness for emergencies in the face of increasing urbanisation. It finds that the organisation is fixated on a top-down approach with low cooperation, collaboration and coordination with stakeholders, leading to situations where devastation and destruction occur before action is taken. Today, the consensus is that practitioners wean themselves from managing disasters and take to managing risk. Such a redirection of attention calls for the adoption of an appropriate institutional framework: an approach that unites the putative nation beyond competing loyalties to ethnicity, tribe and political entity.

  10. Fermilab tevatron five refrigerator system tests

    International Nuclear Information System (INIS)

    Rode, C.; Ferry, R.; Leiniger, M.; Makara, J.; Misek, J.; Mizicko, D.; Richied, D.; Theilacker, J.

    1982-01-01

    The Fermilab Tevatron refrigeration system is described with the layout illustrated. The compressor control loops, the refrigerator control loops, and magnet control loops (two per refrigerator) are described and each illustrated. The mobile purifier is described. A five refrigerator test is presented, using two compressor buildings, satellite refrigerator concept test and the test current to the writing. The configuration of the five refrigerator test is diagramed

  11. A review and synthesis of recreation ecology research supporting carrying capacity and visitor use management decisionmaking

    Science.gov (United States)

    Marion, Jeff

    2016-01-01

    Resource and experiential impacts associated with visitation to wilderness and other similar backcountry settings have long been addressed by land managers under the context of “carrying capacity” decisionmaking. Determining a maximum level of allowable use, below which high-quality resource and experiential conditions would be sustained, was an early focus in the 1960s and 1970s. However, decades of recreation ecology research have shown that the severity and areal extent of visitor impact problems are influenced by an interrelated array of use-related, environmental, and managerial factors. This complexity, with similar findings from social science research, prompted scientists and managers to develop more comprehensive carrying capacity frameworks, including a new Visitor Use Management framework. These frameworks rely on a diverse array of management strategies and actions, often termed a “management toolbox,” for resolving visitor impact problems. This article reviews the most recent and relevant recreation ecology studies that have been applied in wildland settings to avoid or minimize resource impacts. The key findings and their management implications are highlighted to support the professional management of common trail, recreation site, and wildlife impact problems. These studies illustrate the need to select from a more diverse array of impact management strategies and actions based on an evaluation of problems to identify the most influential factors that can be manipulated.

  12. Building capacity in health facility management: guiding principles for skills transfer in Liberia.

    Science.gov (United States)

    Rowe, Laura A; Brillant, Sister Barbara; Cleveland, Emily; Dahn, Bernice T; Ramanadhan, Shoba; Podesta, Mae; Bradley, Elizabeth H

    2010-03-18

    Management training is fundamental to developing human resources for health. Particularly as Liberia revives its health delivery system, facility and county health team managers are central to progress. Nevertheless, such management skills are rarely prioritized in health training, and sustained capacity building in this area is limited. We describe a health management delivery program in which a north and south institution collaborated to integrate classroom and field-based training in health management and to transfer the capacity for sustained management development in Liberia. We developed and implemented a 6-month training program in health management skills (i.e. strategic problem solving, financial management, human resource management and leadership) delivered by Yale University and Mother Patern College from Liberia, with support from the Clinton HIV/AIDS Initiative. Over three 6-month cycles, responsibility for course instruction was transferred from the north institution to the south institution. A self-administered survey was conducted of all participants completing the course to measure changes in self-rated management skills, the degree to which the course was helpful and met its stated objectives, and faculty members' responsiveness to participant needs as the transfer process occurred. Respondents (n=93, response rate 95.9%) reported substantial improvement in self-reported management skills, and rated the helpfulness of the course and the degree to which the course met its objectives highly. Levels of improvement and course ratings were similar over the three cohorts as the course was transferred to the south institution. We suggest a framework of five elements for implementing successful management training programs that can be transferred and sustained in resource-limited settings, including: 1) use a short-course format focusing on four key skill areas with practical tools; 2) include didactic training, on-site projects, and on-site mentoring; 3

  13. Building capacity in health facility management: guiding principles for skills transfer in Liberia

    Directory of Open Access Journals (Sweden)

    Dahn Bernice T

    2010-03-01

    Full Text Available Abstract Background Management training is fundamental to developing human resources for health. Particularly as Liberia revives its health delivery system, facility and county health team managers are central to progress. Nevertheless, such management skills are rarely prioritized in health training, and sustained capacity building in this area is limited. We describe a health management delivery program in which a north and south institution collaborated to integrate classroom and field-based training in health management and to transfer the capacity for sustained management development in Liberia. Methods We developed and implemented a 6-month training program in health management skills (i.e. strategic problem solving, financial management, human resource management and leadership delivered by Yale University and Mother Patern College from Liberia, with support from the Clinton HIV/AIDS Initiative. Over three 6-month cycles, responsibility for course instruction was transferred from the north institution to the south institution. A self-administered survey was conducted of all participants completing the course to measure changes in self-rated management skills, the degree to which the course was helpful and met its stated objectives, and faculty members' responsiveness to participant needs as the transfer process occurred. Results Respondents (n = 93, response rate 95.9% reported substantial improvement in self-reported management skills, and rated the helpfulness of the course and the degree to which the course met its objectives highly. Levels of improvement and course ratings were similar over the three cohorts as the course was transferred to the south institution. We suggest a framework of five elements for implementing successful management training programs that can be transferred and sustained in resource-limited settings, including: 1 use a short-course format focusing on four key skill areas with practical tools; 2 include

  14. Evaluation of capacity-building program of district health managers in India: a contextualized theoretical framework.

    Science.gov (United States)

    Prashanth, N S; Marchal, Bruno; Kegels, Guy; Criel, Bart

    2014-01-01

    Performance of local health services managers at district level is crucial to ensure that health services are of good quality and cater to the health needs of the population in the area. In many low- and middle-income countries, health services managers are poorly equipped with public health management capacities needed for planning and managing their local health system. In the south Indian Tumkur district, a consortium of five non-governmental organizations partnered with the state government to organize a capacity-building program for health managers. The program consisted of a mix of periodic contact classes, mentoring and assignments and was spread over 30 months. In this paper, we develop a theoretical framework in the form of a refined program theory to understand how such a capacity-building program could bring about organizational change. A well-formulated program theory enables an understanding of how interventions could bring about improvements and an evaluation of the intervention. In the refined program theory of the intervention, we identified various factors at individual, institutional, and environmental levels that could interact with the hypothesized mechanisms of organizational change, such as staff's perceived self-efficacy and commitment to their organizations. Based on this program theory, we formulated context-mechanism-outcome configurations that can be used to evaluate the intervention and, more specifically, to understand what worked, for whom and under what conditions. We discuss the application of program theory development in conducting a realist evaluation. Realist evaluation embraces principles of systems thinking by providing a method for understanding how elements of the system interact with one another in producing a given outcome.

  15. Helium refrigeration system for hydrogen liquefaction applications

    Science.gov (United States)

    Nair, J. Kumar, Sr.; Menon, RS; Goyal, M.; Ansari, NA; Chakravarty, A.; Joemon, V.

    2017-02-01

    Liquid hydrogen around 20 K is used as cold moderator for generating “cold neutron beam” in nuclear research reactors. A cryogenic helium refrigeration system is the core upon which such hydrogen liquefaction applications are built. A thermodynamic process based on reversed Brayton cycle with two stage expansion using high speed cryogenic turboexpanders (TEX) along with a pair of compact high effectiveness process heat exchangers (HX), is well suited for such applications. An existing helium refrigeration system, which had earlier demonstrated a refrigeration capacity of 470 W at around 20 K, is modified based on past operational experiences and newer application requirements. Modifications include addition of a new heat exchanger to simulate cryogenic process load and two other heat exchangers for controlling the temperatures of helium streams leading out to the application system. To incorporate these changes, cryogenic piping inside the cold box is suitably modified. This paper presents process simulation, sizing of new heat exchangers as well as fabrication aspects of the modified cryogenic process piping.

  16. Letting the managers manage: analyzing capacity to conserve biodiversity in a cross-border protected area network

    Directory of Open Access Journals (Sweden)

    Sarah Clement

    2016-09-01

    Full Text Available Biodiversity loss is one of the most significant drivers of ecosystem change and is projected to continue at a rapid rate. While protected areas, such as national parks, are seen as important refuges for biodiversity, their effectiveness in stemming biodiversity decline has been questioned. Public agencies have a critical role in the governance of many such areas, but there are tensions between the need for these agencies to be more "adaptive" and their current operating environment. Our aim is to analyze how institutions enable or constrain capacity to conserve biodiversity in a globally significant cross-border network of protected areas, the Australian Alps. Using a novel conceptual framework for diagnosing biodiversity institutions, our research examined institutional adaptive capacity and more general capacity for conserving biodiversity. Several intertwined issues limit public agencies' capacity to fulfill their conservation responsibilities. Narrowly defined accountability measures constrain adaptive capacity and divert attention away from addressing key biodiversity outcomes. Implications for learning were also evident, with protected area agencies demonstrating successful learning for on-ground issues but less success in applying this learning to deeper policy change. Poor capacity to buffer political and community influences in managing significant cross-border drivers of biodiversity decline signals poor fit with the institutional context and has implications for functional fit. While cooperative federalism provides potential benefits for buffering through diversity, it also means protected area agencies have restricted authority to address cross-border threats. Restrictions on staff authority and discretion, as public servants, have further implications for deploying capacity. This analysis, particularly the possibility of fostering "ambidexterity" - creatively responding to political pressures in a way that also achieves a desirable

  17. Commissioning and operation of the CEBAF end station refrigeration system

    International Nuclear Information System (INIS)

    Arenius, D.; Bevins, B.; Chronis, W.C.; Ganni, V.

    1996-01-01

    The CEBAF End Station Helium Refrigerator (ESR) System provides refrigeration at 80 K, 20 K and 4.5 K to three End Station experimental halls. The facility consists of a two stage helium screw compressor system, 4.5 K refrigerator, cryogen distribution valve box, and transfer lines to the individual experimental halls. The 4.5 K cold box and compressors were originally part of the ESCAR 1500 W, 4 K refrigeration system at Lawrence Berkeley Laboratory which was first commissioned in 1977. The compressors, 4.5 K cold box, and control system design were modified to adapt the plant for the requirements of the CEBAF experimental halls. Additional subsystems of cryogen distribution, transfer lines, warm gas management, and computer control interface were added. This paper describes the major plant subsystems, modifications, operational experiences and performance

  18. Energy optimisation of domestic refrigerators

    DEFF Research Database (Denmark)

    Jakobsen, Arne; Rasmussen, Bjarne D.

    1998-01-01

    This paper describes the main results of a research project with the objective of reducing the energy consumption of domestic refrigerators by increasing the efficiency of the refrigeration system. The improvement of the system efficiency was to be obtained by:1) Introducing continuous operation ...

  19. Cryo-refrigerators for CNS applications

    International Nuclear Information System (INIS)

    Clausen, J.; Lesser, J.; Sebastianutto, R.

    2001-01-01

    Cryo-refrigeration plants for cold neutron sources belong to the field of auxiliary plants or utility facilities of the reactor. In general, they are classified as non-nuclear and serve to dissipate the heat generated in the liquid hydrogen or deuterium from moderating the neutrons of the cold neutron source. Cryo-refrigeration plants for the temperature range of 20 K supply either refrigeration at constant temperature by means of evaporating the cryogenic coolant (usually hydrogen) or, as usual with cold sources, in a specific temperature range by means of warming-up the cryogenic coolant (usually helium) in the moderator or heat exchanger (condensation or subcooling of the deuterium). The operator's requirements to a refrigeration plant are, first of all, that the plant adjusts itself - at low-maintenance or maintenance-free - to the various operation modes at best thermodynamic efficiencies and that it offers as much operating convenience and operating safety as possible. Additional requirements are short times for cool-down, capacity adjustment, stand-by operation in order to avoid poisoning of the cold source and further operational requirements. However, these requirements are limited by mechanics, thermodynamics and financial means. For this reason, for each application a technical solution must be found which is optimally adapted to the competing requirements and which is based on a standard product of the manufacturer, if possible. The operator's different requirements have to be taken in account with regard to the design of the plant and choice of the components; economic aspects in addition also have to be considered. Wherever possible, proven standard components should be used. (orig.)

  20. Regulating Power from Supermarket Refrigeration

    DEFF Research Database (Denmark)

    O'Connell, Niamh; Madsen, Henrik; Pinson, Pierre

    2014-01-01

    the Danfoss refrigeration test centre. The complexities of modelling demand response are demonstrated through simulation. Simulations are conducted by placing the identified model in a direct-control demand response architecture, with power reference tracking using model predictive control. The energylimited......This paper presents an analysis of the demand response capabilities of a supermarket refrigeration system, with a particular focus on the suitability for participation in the regulating power market. An ARMAX model of a supermarket refrigeration system is identified using experimental data from...... nature of demand response from refrigeration is identified as the key consideration when considering participation in the regulating power market. It is demonstrated that by restricting the operating regions of the supermarket refrigeration system, a simple relationship can be found between the available...

  1. Universities in capacity building in sustainable development: focus on solid waste management and technology.

    Science.gov (United States)

    Agamuthu, P; Hansen, Jens Aage

    2007-06-01

    This paper analyses some of the higher education and research capacity building experiences gained from 1998-2006 by Danish and Malaysian universities. The focus is on waste management, directly relating to both the environmental and socio-economic dimensions of sustainable development. Primary benefits, available as an educational legacy to universities, were obtained in terms of new and enhanced study curricula established on Problem-oriented Project-based Learning (POPBL) pedagogy, which strengthened academic environmental programmes at Malaysian and Danish universities. It involved more direct and mutually beneficial cooperation between academia and businesses in both countries. This kind of university reach-out is considered vital to development in all countries actively striving for global and sustainable development. Supplementary benefits were accrued for those involved directly in activities such as the 4 months of field studies, workshops, field courses and joint research projects. For students and academics, the gains have been new international dimensions in university curricula, enhanced career development and research collaboration based on realworld cases. It is suggested that the area of solid waste management offers opportunities for much needed capacity building in higher education and research, contributing to sustainable waste management on a global scale. Universities should be more actively involved in such educational, research and innovation programmes to make the necessary progress. ISWA can support capacity building activities by utilizing its resources--providing a lively platform for debate, securing dissemination of new knowledge, and furthering international networking beyond that which universities already do by themselves. A special challenge to ISWA may be to improve national and international professional networks between academia and business, thereby making education, research and innovation the key driving mechanisms in

  2. Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

    Directory of Open Access Journals (Sweden)

    Mishra Shubham

    2016-12-01

    Full Text Available Performance assessment of ejector-expansion vapor compression refrigeration system with eco-friendly R134a alternative refrigerants (R152a, R1234yf, R600a, R600, R290, R161, R32, and propylene is presented for air-conditioning application. Ejector has been modeled by considering experimental data based correlations of component efficiencies to take care of all irreversibilities. Ejector area ratio has been optimized based on maximum coefficient of performance (COP for typical air-conditioner operating temperatures. Selected refrigerants have been compared based on area ratio, pressure lift ratio, entrainment ratio, COP, COP improvement and volumetric cooling capacity. Effects of normal boiling point and critical point on the performances have been studied as well. Using ejector as an expansion device, maximum improvement in COP is noted in R1234yf (10.1%, which reduces the COP deviation with R134a (4.5% less in basic cycle and 2.5% less in ejector cycle. Hence, R1234yf seems to be best alternative for ejector expansion system due to its mild flammability and comparable volumetric capacity and cooling COP. refrigerant R161 is superior to R134a in terms of both COP and volumetric cooling capacity, although may be restricted for low capacity application due to its flammability.

  3. Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

    Science.gov (United States)

    Mishra, Shubham; Sarkar, Jahar

    2016-12-01

    Performance assessment of ejector-expansion vapor compression refrigeration system with eco-friendly R134a alternative refrigerants (R152a, R1234yf, R600a, R600, R290, R161, R32, and propylene) is presented for air-conditioning application. Ejector has been modeled by considering experimental data based correlations of component efficiencies to take care of all irreversibilities. Ejector area ratio has been optimized based on maximum coefficient of performance (COP) for typical air-conditioner operating temperatures. Selected refrigerants have been compared based on area ratio, pressure lift ratio, entrainment ratio, COP, COP improvement and volumetric cooling capacity. Effects of normal boiling point and critical point on the performances have been studied as well. Using ejector as an expansion device, maximum improvement in COP is noted in R1234yf (10.1%), which reduces the COP deviation with R134a (4.5% less in basic cycle and 2.5% less in ejector cycle). Hence, R1234yf seems to be best alternative for ejector expansion system due to its mild flammability and comparable volumetric capacity and cooling COP. refrigerant R161 is superior to R134a in terms of both COP and volumetric cooling capacity, although may be restricted for low capacity application due to its flammability.

  4. Developing additional capacity for wilderness management: An international exchange program between South Africa and United States wilderness rangers

    Science.gov (United States)

    Pierre van den Berg; Ralph Swain

    2007-01-01

    Wilderness managers have limited time to initiate international exchanges. Additionally, the benefits to developing capacity for wilderness management around the globe are not significant enough to make the effort cost-effective. International assistance, including wilderness management exchange programs, is critical to protecting wild areas around the globe. Former...

  5. Food Safety Practices Linked with Proper Refrigerator Temperatures in Retail Delis.

    Science.gov (United States)

    Brown, Laura G; Hoover, Edward Rickamer; Faw, Brenda V; Hedeen, Nicole K; Nicholas, David; Wong, Melissa R; Shepherd, Craig; Gallagher, Daniel L; Kause, Janell R

    2018-05-01

    Listeria monocytogenes (L. monocytogenes) causes the third highest number of foodborne illness deaths annually. L. monocytogenes contamination of sliced deli meats at the retail level is a significant contributing factor to L. monocytogenes illness. The Centers for Disease Control and Prevention's Environmental Health Specialists Network (EHS-Net) conducted a study to learn more about retail delis' practices concerning L. monocytogenes growth and cross-contamination prevention. This article presents data from this study on the frequency with which retail deli refrigerator temperatures exceed 41°F, the Food and Drug Administration (FDA)-recommended maximum temperature for ready-to-eat food requiring time and temperature control for safety (TCS) (such as retail deli meat). This provision was designed to control bacterial growth in TCS foods. This article also presents data on deli and staff characteristics related to the frequency with which retail delis refrigerator temperatures exceed 41°F. Data from observations of 445 refrigerators in 245 delis showed that in 17.1% of delis, at least one refrigerator was >41°F. We also found that refrigeration temperatures reported in this study were lower than those reported in a related 2007 study. Delis with more than one refrigerator, that lacked refrigerator temperature recording, and had a manager who had never been food safety certified had greater odds of having a refrigerator temperature >41°F. The data from this study suggest that retail temperature control is improving over time. They also identify a food safety gap: some delis have refrigerator temperatures that exceed 41°F. We also found that two food safety interventions were related to better refrigerated storage practices: kitchen manager certification and recording refrigerated storage temperatures. Regulatory food safety programs and the retail industry may wish to consider encouraging or requiring kitchen manager certification and recording refrigerated

  6. Component-wise exergy and energy analysis of vapor compression refrigeration system using mixture of R134a and LPG as refrigerant

    Science.gov (United States)

    Gill, Jatinder; Singh, Jagdev

    2017-11-01

    In this work, the experimental examination was carried out using a mixture of R134a and LPG refrigerant (consisting of R134a and LPG in a proportion of 28:72 by weight) as a replacement for R134a in a vapor compression refrigeration system. Exergy and energy tests were carried out at different evaporator and condenser temperatures with controlled environmental conditions. The results showed that the exergy destruction in the compressor, condenser, evaporator, and a capillary tube of the R134a / LPG refrigeration system was found lower by approximately 11.13-3.41%, 2.24-3.43%, 12.02-13.47% and 1.54-5.61% respectively. The compressor exhibits the highest level of destruction, accompanied by a condenser, an evaporator and a capillary tube in refrigeration systems. The refrigeration capacity, COP and power consumption of the compressor of the R134a /LPG refrigeration system were detected higher and lower compared to the R134a refrigeration system by about 7.04-11.41%, 15.1-17.82%, and 3.83-8.08% respectively. Also, the miscibility of R134a and LPG blend with mineral oil discovered good. The R134a and LPG refrigerant mixture proposed in this study perform superior to R134a from component-wise exergy and energy analyses under similar experimental conditions.

  7. Component-wise exergy and energy analysis of vapor compression refrigeration system using mixture of R134a and LPG as refrigerant

    Science.gov (United States)

    Gill, Jatinder; Singh, Jagdev

    2018-05-01

    In this work, the experimental examination was carried out using a mixture of R134a and LPG refrigerant (consisting of R134a and LPG in a proportion of 28:72 by weight) as a replacement for R134a in a vapor compression refrigeration system. Exergy and energy tests were carried out at different evaporator and condenser temperatures with controlled environmental conditions. The results showed that the exergy destruction in the compressor, condenser, evaporator, and a capillary tube of the R134a / LPG refrigeration system was found lower by approximately 11.13-3.41%, 2.24-3.43%, 12.02-13.47% and 1.54-5.61% respectively. The compressor exhibits the highest level of destruction, accompanied by a condenser, an evaporator and a capillary tube in refrigeration systems. The refrigeration capacity, COP and power consumption of the compressor of the R134a /LPG refrigeration system were detected higher and lower compared to the R134a refrigeration system by about 7.04-11.41%, 15.1-17.82%, and 3.83-8.08% respectively. Also, the miscibility of R134a and LPG blend with mineral oil discovered good. The R134a and LPG refrigerant mixture proposed in this study perform superior to R134a from component-wise exergy and energy analyses under similar experimental conditions.

  8. Building Critical Infrastructure resilience capacities into the Emergency Management set-up: a reference framework

    DEFF Research Database (Denmark)

    Trucco, P.; Petrenj, B.; Kozine, Igor

    proposes a comprehensive framework to identify, build and enhance specific capabilities, both intra- and inter-organisational, needed to manage (prepare, cope and recover from) CI disruptions. This allows emergency services to assess and explicitly address resilience improvement measures while planning......, resources and processes specifically arranged to accomplish a critical task and assure a key objective. Each capability contributes to one or more resilience capacities (preventive, absorptive, adaptive and restorative). An overall resilience capability building cycle completes the framework, enabling...... a systematic implementation of relevant capabilities and making gap analysis with regard to resilience deficits. The planning of training exercises to enhance CI resilience can also benefit from the approach....

  9. Performance of an auto refrigerant cascade refrigerator operating in gas refrigerant supply (GRS) mode with nitrogen-hydrocarbon and argon-hydrocarbon refrigerants

    Science.gov (United States)

    Gurudath Nayak, H.; Venkatarathnam, G.

    2009-07-01

    There is a worldwide interest in the development of auto refrigerant cascade (ARC) refrigerators operating with refrigerant mixtures. Both flammable and non-flammable refrigerant mixtures can be used in these systems. The performance of an ARC system with optimum nitrogen-hydrocarbon and argon-hydrocarbon mixtures between 90 and 160 K is presented in this paper.

  10. Experimental and Numerical Study of Effect of Thermal Management on Storage Capacity of the Adsorbed Natural Gas Vessel

    KAUST Repository

    Ybyraiymkul, Doskhan; Ng, Kim Choon; Кaltayev, Aidarkhan

    2017-01-01

    One of the main challenges in the adsorbed natural gas (ANG) storage system is the thermal effect of adsorption, which significantly lowers storage capacity. These challenges can be solved by efficient thermal management system. In this paper

  11. Conditions for the management of carrying capacity in the parks of Parks&Benefits

    DEFF Research Database (Denmark)

    Brandt, Jesper; Holmes, Esbern

    2011-01-01

    Growth in the number of visitors is an upcoming problem in nature parks. Nature parks are at the same time facing increasing demand, falling public appropriations and receding focus on their conservation functions. To ensure a balancing of nature protection and economic utilization the concept...... stakeholders, balancing use and protection preferably based on scientific and/or experiential cognition. The conditions for the management of carrying capacity for the 8 nature parks in the EC Baltic Project Parks&Benefits are analysed in the report. 1. Part focus on the methodology, concentrated...... on the comparison of the common conditions related to the international nature protection obligations in the parks, primarily expressed through the management under the EU Natura2000-program. In part 2, a comparison of the 8 parks concerning extent, land use composition, population in and around the park...

  12. Rules for congestion management. Evaluation of available of capacity and possibilities for increased counter trade

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-08-01

    In the Nordic electricity market, congestion is currently managed using two methods: a combination of price areas (market splitting) and counter-trade. In the planning phase (one day ahead) the main method employed is market splitting, although moving internal bottlenecks to the country border and domestic counter-trade are also used to some degree. Congestion is solved through counter- trade in the operating phase (during the day). In spring 2002, Nordel published a report with proposals for possible changes in Nordic congestion management. The main proposal was to introduce new price areas in the spot market and let the borders of price areas coincide with the physical borders of congestion in the transmission network to a greater degree. It was also proposed to increase the use of counter-trade. Based on feedback from Nordic market players, Nordel decided to carry on the work with congestion management in a new ad hoc group. The group's mandate was a Nordic harmonization of rules and practices for congestion management and a socio-economically efficient utilisation of the transmission grid capacity. Furthermore, the group was asked to investigate how to ensure optimal availability of capacity and to look into the possibilities of increasing usage of counter-trade. The ad hoc working group results are presented in this report. Among the conclusions drawn from the investigations are: 1) A limited increase of counter-trade in the planning phase is feasible for temporary congestion in order to reduce the area price risks for the market players, 2) Market participants should be consulted to get their views on whether and to what extent counter-trade should be increased taking benefits and costs into account. The extent of counter-trade could e.g. be decided as a percentage of NCT with intact grid, 3) Nordel should consider a practice where counter-trading is used to prevent reductions in cross-border capacity due to maintenance, 4) The use of counter-trade in

  13. Rules for congestion management. Evaluation of availability of capacity and possibilities for increased counter trade

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-08-01

    In the Nordic electricity market, congestion is currently managed using two methods: a combination of price areas (market splitting) and counter-trade. In the planning phase (one day ahead) the main method employed is market splitting, although moving internal bottlenecks to the country border and domestic counter-trade are also used to some degree. Congestion is solved through counter- trade in the operating phase (during the day). In spring 2002, Nordel published a report with proposals for possible changes in Nordic congestion management. The main proposal was to introduce new price areas in the spot market and let the borders of price areas coincide with the physical borders of congestion in the transmission network to a greater degree. It was also proposed to increase the use of counter-trade. Based on feedback from Nordic market players, Nordel decided to carry on the work with congestion management in a new ad hoc group. The group's mandate was a Nordic harmonization of rules and practices for congestion management and a socio-economically efficient utilisation of the transmission grid capacity. Furthermore, the group was asked to investigate how to ensure optimal availability of capacity and to look into the possibilities of increasing usage of counter-trade. The ad hoc working group results are presented in this report. Among the conclusions drawn from the investigations are: 1) A limited increase of counter-trade in the planning phase is feasible for temporary congestion in order to reduce the area price risks for the market players, 2) Market participants should be consulted to get their views on whether and to what extent counter-trade should be increased taking benefits and costs into account. The extent of counter-trade could e.g. be decided as a percentage of NCT with intact grid, 3) Nordel should consider a practice where counter-trading is used to prevent reductions in cross-border capacity due to maintenance, 4) The use of counter-trade in

  14. Rules for congestion management. Evaluation of availability of capacity and possibilities for increased counter trade

    International Nuclear Information System (INIS)

    2004-08-01

    In the Nordic electricity market, congestion is currently managed using two methods: a combination of price areas (market splitting) and counter-trade. In the planning phase (one day ahead) the main method employed is market splitting, although moving internal bottlenecks to the country border and domestic counter-trade are also used to some degree. Congestion is solved through counter- trade in the operating phase (during the day). In spring 2002, Nordel published a report with proposals for possible changes in Nordic congestion management. The main proposal was to introduce new price areas in the spot market and let the borders of price areas coincide with the physical borders of congestion in the transmission network to a greater degree. It was also proposed to increase the use of counter-trade. Based on feedback from Nordic market players, Nordel decided to carry on the work with congestion management in a new ad hoc group. The group's mandate was a Nordic harmonization of rules and practices for congestion management and a socio-economically efficient utilisation of the transmission grid capacity. Furthermore, the group was asked to investigate how to ensure optimal availability of capacity and to look into the possibilities of increasing usage of counter-trade. The ad hoc working group results are presented in this report. Among the conclusions drawn from the investigations are: 1) A limited increase of counter-trade in the planning phase is feasible for temporary congestion in order to reduce the area price risks for the market players, 2) Market participants should be consulted to get their views on whether and to what extent counter-trade should be increased taking benefits and costs into account. The extent of counter-trade could e.g. be decided as a percentage of NCT with intact grid, 3) Nordel should consider a practice where counter-trading is used to prevent reductions in cross-border capacity due to maintenance, 4) The use of counter-trade in the

  15. Water infiltration capacity under different land uses and agricultural management practices

    Directory of Open Access Journals (Sweden)

    Lizandra Poeta Teixeira

    2009-08-01

    Full Text Available Knowledge of physical and hydraulic properties of soil is important for the appropriate use and management of soil, and for the understanding of dynamic movement process of water and solutes. This study aims to determine the soil infiltration capacity of the Concordia Experimental Basin, located in the municipality of Lontras in Santa Catarina state. The infiltration tests were performed with the concentric ring infiltrometer, with a diameter of 25 and 50 cm on twenty sampling points showing different uses of land and agricultural management practices. The initial capacity of infiltration, calculated by Horton's equation, ranged from 0.8 (pasture to 5.0 cm min-1 (pine forest and cassava planting. In pasture areas, the initial infiltration ranged from 0.8 to 0.9 cm min-1. Regarding the minimum value, they ranged from 0.01 (perennial pasture to 0.3 cm min-1 (minimum tillage for corn. In forest areas, the minimum infiltration varied between 0.05 and 0.15 cm min-1 and in the areas of pasture, it was equal to 0.01 cm min-1.

  16. Experimental investigation of integrated refrigeration system (IRS) with gas engine, compression chiller and absorption chiller

    International Nuclear Information System (INIS)

    Sun, Z.G.

    2008-01-01

    An integrated refrigeration system (IRS) with a gas engine, a vapor-compression chiller and an absorption chiller is set up and tested. The vapor-compression refrigeration cycle is operated directly by the gas engine. The waste heat from the gas engine operates the absorption refrigeration cycle, which provides additional cooling. The performance of the IRS is described. The cooling capacity of the IRS is about 596 kW, and primary energy ratio (PER) reaches 1.84 at air-conditioning rated conditions. The refrigerating capacity of the prototype increased and PER of prototype decreased with the increase of the gas engine speed. The gas engine speed was preferably regulated at part load condition in order to operate the prototype at high-energy efficiency. The refrigerating capacity and PER of the prototype increased with the increase of the outlet temperature of chilled water or the decrease of the inlet temperature of cooling water. The integrated refrigeration chiller in this work saves running costs as compared to the conventional refrigeration system by using the waste heat

  17. Modelling refrigerant distribution in minichannel evaporators

    DEFF Research Database (Denmark)

    Brix, Wiebke

    of the liquid and vapour in the inlet manifold. Combining non-uniform airflow and non-uniform liquid and vapour distribution shows that a non-uniform airflow distribution to some degree can be compensated by a suitable liquid and vapour distribution. Controlling the superheat out of the individual channels...... to be equal, results in a cooling capacity very close to the optimum. A sensitivity study considering parameter changes shows that the course of the pressure gradient in the channel is significant, considering the magnitude of the capacity reductions due to non-uniform liquid and vapour distribution and non......This thesis is concerned with numerical modelling of flow distribution in a minichannel evaporator for air-conditioning. The study investigates the impact of non-uniform airflow and non-uniform distribution of the liquid and vapour phases in the inlet manifold on the refrigerant mass flow...

  18. Construction, commissioning and initial operation of 2400W refrigerator and cold test stand for CDM testing

    International Nuclear Information System (INIS)

    Dubbs, J.D.; Kreinbrink, K.

    1994-01-01

    Air Products and CVI collaborated to design, construct and commission a refrigerator, test stands and integrated control system for the General Dynamics Collider Dipole Magnet Cold Test Facility (CTF) in Hammond, LA. The original project schedule required the cold test facility to be operational within 17 months of the notice to proceed. Midway through the project, changes in General Dynamics magnet testing requirements necessitated doubling the plant capacity, but the on stream date for the initial capacity increment could not be relaxed. The Air Products/CVI team had to adapt the project execution strategy to mitigate the schedule impact of the expansion in a cost effective manner without impacting system functionality, quality or safety. An equally challenging aspect of the job was that the (CTF) was being designed while several major systems that would interface with the CTF were being engineered. General Dynamics, Air Products and CVI had to work very closely to manage the interface issues. The teams efforts were very successful. The Hammond refrigerator/liquifier was started up on schedule. The first two test stands are currently being commissioned and will be on stream just six weeks later than the pre-expansion schedule target and all four test stands will be operational in time to support General Dynamics magnet testing requirements

  19. Thermoacoustic refrigerator for space applications

    Science.gov (United States)

    Garrett, Steven L.; Adeff, Jay A.; Hofler, Thomas J.

    1993-10-01

    A new spacecraft cryocooler which uses resonant high-amplitude sound waves in inert gases to pump heat is described. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). A space-qualified thermoacoustic refrigerator was flown on the Space Shuttle Discovery (STS-42) in January, 1992. It was entirely autonomous, had no sliding seals, required no lubrication, used mostly low-tolerance machined parts, and contained no expensive components. Thermoacoustics is shown to be a competitive candidate for food refrigerator/freezers and commercial/residential air conditioners. The design and performance of the Space Thermo/Acoustic Refrigerator (STAR) is described.

  20. Magnetic refrigeration apparatus and method

    Science.gov (United States)

    Barclay, John A.; Overton, Jr., William C.; Stewart, Walter F.

    1984-01-01

    The disclosure relates to refrigeration through magnetizing and demagnitizing a body by rotating it within a magnetic field. Internal and external heat exchange fluids and in one embodiment, a regenerator, are used.

  1. ENERGY STAR Certified Residential Refrigerators

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Residential Refrigerators and Freezers that are...

  2. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A; Jurkowski, R [CIAT, 01 - Culoz (France)

    1998-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  3. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A.; Jurkowski, R. [CIAT, 01 - Culoz (France)

    1997-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  4. Influence of special attributes of zeotropic refrigerant mixtures on design and operation of vapour compression refrigeration and heat pump systems

    International Nuclear Information System (INIS)

    Rajapaksha, Leelananda

    2007-01-01

    The use of zeotropic refrigerant mixtures introduces a number of novel issues that affect the established design and operational practices of vapour compression systems used in refrigeration, air conditioning and heat pump applications. Two attributes; composition shift and temperature glide, associated with the phase changing process of zeotropic mixtures are the primary phenomena that bring in these issues. However, relevant researches are uncovering ways how careful system designs and selection of operational parameters allow improving the energy efficiency and the capacity of vapour compression refrigeration systems. Most of these concepts exploit the presence of composition shift and temperature glide. This paper qualitatively discusses how the mixture attributes influence the established heat exchanger design practices, performance and operation of conventional vapour compression systems. How the temperature glide and composition shift can be incorporated to improve the system performance and the efficiency are also discussed

  5. A review of health leadership and management capacity in the Solomon Islands.

    Science.gov (United States)

    Asante, Augustine; Roberts, Graham; Hall, John

    2012-04-01

    and to Ministry of Finance and Public Service Division regulations. The delineation of central and provincial health authorities' responsibilities requires guidelines in a changing system, where both population-based and targeted vertical programs are implemented at local levels. NUMBER AND DISTRIBUTION OF MANAGERS: Nine of the 10 positions of Provincial Health Director have experienced high turnover, which reportedly occurs without adequate handover to incoming appointees, most of whom are recent clinical graduates. Health services in the Honiara urban area are provided through the Honiara City Council. Church health services are staffed by government employees. COMPETENCE OF DISTRICT HEALTH MANAGERS: Management skills are reportedly weak at the provincial level. The Regional Assistance Mission to Solomon Islands provides governance training inputs to provincial government staff. Provincial health departments have limited financial and human resource management capacity. They also have clinical backgrounds and no training in public health planning or health services management, other than that provided by donors, the Regional Assistance Mission itself and the MHMS. MANAGEMENT WORKING ENVIRONMENT: Provincial health directors have limited control over health staff. Little supportive supervision in management is provided to new provincial health directors. No performance management systems are in place to ensure that staff are properly assessed and supported to do their best Large numbers of non-government organisations working at the provincial level in youth and women's programs require coordination by Provincial health directors to avoid duplication or implementation of programs that will require ongoing funding, but this is not done. FUNCTIONING OF MANAGEMENT SUPPORT SYSTEMS: Management support systems for budgeting and finance, management information and procurement and supply do not function adequately to support provincial health directors to manage effectively

  6. Refrigeration plants for the SSCL

    International Nuclear Information System (INIS)

    McAshan, M.; Ganni, V.; Than, R.; Niehaus, T.

    1991-03-01

    The basic requirements and operating features of the collider cryogenic system have already been described in other publications. The general arrangement of the refrigeration plant and its subsystems is presented, and the issue of how to provide redundancy in the cryogenic system is addressed, and some of the basic features of the refrigeration plants are described. The collider cryogenic system design is not final yet, and this report only reflects the direction and current status of the cryogenic system design

  7. Building capacity for HIV/AIDS program leadership and management in Uganda through mentored Fellowships.

    Science.gov (United States)

    Matovu, Joseph K B; Wanyenze, Rhoda K; Mawemuko, Susan; Wamuyu-Maina, Gakenia; Bazeyo, William; Olico-Okui; Serwadda, David

    2011-02-24

    Around the world, health professionals and program managers are leading and managing public and private health organizations with little or no formal management and leadership training and experience. To describe an innovative 2-year, long-term apprenticeship Fellowship training program implemented by Makerere University School of Public Health (MakSPH) to strengthen capacity for leadership and management of HIV/AIDS programs in Uganda. IMPLEMENTATION PROCESS: The program, which began in 2002, is a 2-year, full-time, non-degree Fellowship. It is open to Ugandan nationals with postgraduate training in health-related disciplines. Enrolled Fellows are attached to host institutions implementing HIV/AIDS programs and placed under the supervision of host institution and academic mentors. Fellows spend 75% of their apprenticeship at the host institutions while the remaining 25% is dedicated to didactic short courses conducted at MakSPH to enhance their knowledge base. Overall, 77 Fellows have been enrolled since 2002. Of the 57 Fellows who were admitted between 2002 and 2008, 94.7% (54) completed the Fellowship successfully and 50 (92.3%) are employed in senior leadership and management positions in Uganda and internationally. Eighty-eight percent of those employed (44/54) work in institutions registered in Uganda, indicating a high level of in-country retention. Nineteen of the 20 Fellows who were admitted between 2009 and 2010 are still undergoing training. A total of 67 institutions have hosted Fellows since 2002. The host institutions have benefited through staff training and technical expertise from the Fellows as well as through grant support to Fellows to develop and implement innovative pilot projects. The success of the program hinges on support from mentors, stakeholder involvement, and the hands-on approach employed in training. The Fellowship Program offers a unique opportunity for hands-on training in HIV/AIDS program leadership and management for both

  8. Building capacity for HIV/AIDS program leadership and management in Uganda through mentored Fellowships

    Directory of Open Access Journals (Sweden)

    Joseph K.B. Matovu

    2011-02-01

    Full Text Available Background: Around the world, health professionals and program managers are leading and managing public and private health organizations with little or no formal management and leadership training and experience. Objective: To describe an innovative 2-year, long-term apprenticeship Fellowship training program implemented by Makerere University School of Public Health (MakSPH to strengthen capacity for leadership and management of HIV/AIDS programs in Uganda. Implementation process: The program, which began in 2002, is a 2-year, full-time, non-degree Fellowship. It is open to Ugandan nationals with postgraduate training in health-related disciplines. Enrolled Fellows are attached to host institutions implementing HIV/AIDS programs and placed under the supervision of host institution and academic mentors. Fellows spend 75% of their apprenticeship at the host institutions while the remaining 25% is dedicated to didactic short courses conducted at MakSPH to enhance their knowledge base. Achievements: Overall, 77 Fellows have been enrolled since 2002. Of the 57 Fellows who were admitted between 2002 and 2008, 94.7% (54 completed the Fellowship successfully and 50 (92.3% are employed in senior leadership and management positions in Uganda and internationally. Eighty-eight percent of those employed (44/54 work in institutions registered in Uganda, indicating a high level of in-country retention. Nineteen of the 20 Fellows who were admitted between 2009 and 2010 are still undergoing training. A total of 67 institutions have hosted Fellows since 2002. The host institutions have benefited through staff training and technical expertise from the Fellows as well as through grant support to Fellows to develop and implement innovative pilot projects. The success of the program hinges on support from mentors, stakeholder involvement, and the hands-on approach employed in training. Conclusion: The Fellowship Program offers a unique opportunity for hands

  9. Capacity building in water demand management as a key component for attaining millennium development goals

    Science.gov (United States)

    Gumbo, Bekithemba; Forster, Laura; Arntzen, Jaap

    Successful water demand management (WDM) implementation as a component of integrated water resource management (IWRM) can play a significant role in the alleviation of poverty through more efficient use of available water resources. The urban population in Southern African cities is characterised by so-called ‘water poor’ communities who typically expend a high percentage of their household income on poor quality water. Usually they have no access to an affordable alternative source. Although WDM as a component of IWRM is not a panacea for poverty, it can help alleviate poverty by facilitating water services management by municipal water supply agencies (MWSAs) in the region. WDM is a key strategy for achieving the millennium development goals (MDGs) and, as such, should be given due attention in the preparation of national IWRM and water efficiency plans. Various studies in the Southern African region have indicated that capacity building is necessary for nations to develop IWRM and water-use efficiency plans to meet the targets set out in the MDGs. WDM education and training of water professionals and end-users is particularly important in developing countries, which are resource and information-access poor. In response to these findings, The World Conservation Union (IUCN) and its consulting partners, the Training and Instructional Design Academy of South Africa (TIDASA), and Centre for Applied Research (CAR) designed, developed and presented a pilot WDM Guideline Training Module for MWSAs as part of Phase II of IUCN’s Southern Africa regional WDM project. Pilot training was conducted in July 2004 in Lusaka, Zambia for a group of 36 participants involved in municipal water supply from nine Southern African countries. This paper looks at the links between building the capacity of professionals, operational staff and other role-players in the municipal water supply chain to implement WDM as part of broader IWRM strategies, and the subsequent potential for

  10. Optimization of Multi-layer Active Magnetic Regenerator towards Compact and Efficient Refrigeration

    DEFF Research Database (Denmark)

    Lei, Tian; Engelbrecht, Kurt; Nielsen, Kaspar Kirstein

    2016-01-01

    Magnetic refrigerators can theoretically be more efficient than current vapor compression systems and use no vapor refrigerants with global warming potential. The core component, the active magnetic regenerator (AMR) operates based on the magnetocaloric effect of magnetic materials and the heat r....... In addition, simulations are carried out to investigate the potential of applying nanofluid in future magnetic refrigerators.......Magnetic refrigerators can theoretically be more efficient than current vapor compression systems and use no vapor refrigerants with global warming potential. The core component, the active magnetic regenerator (AMR) operates based on the magnetocaloric effect of magnetic materials and the heat...... their Curie temperature. Simulations are implemented to investigate how to layer the FOPT materials for obtaining higher cooling capacity. Moreover, based on entropy generation minimization, optimization of the regenerator geometry and related operating parameters is presented for improving the AMR efficiency...

  11. Refrigeration Performance and Entropy Generation Analysis for Reciprocating Magnetic Refrigerator with Gd Plates

    Directory of Open Access Journals (Sweden)

    Yonghua You

    2018-06-01

    Full Text Available In the current work, a novel 2D numerical model of stationary grids was developed for reciprocating magnetic refrigerators, with Gd plates, in which the magneto-caloric properties, derived from the Weiss molecular field theory, were adopted for the built-in energy source of the magneto-caloric effect. The numerical simulation was conducted under the conditions of different structural and operational parameters, and the effects of the relative fluid displacement (φ on the specific refrigeration capacity (qref and the Coefficient of Performance (COP were obtained. Besides the variations of entropy, the generation rate and number were studied and the contours of the local entropy generation rate are presented for discussion. From the current work, it is found that with an increase in φ, both the qref and COP followed the convex variation trend, while the entropy generation number (Ns varied concavely. As for the current cases, the maximal qref and COP were equal to 151.2 kW/m3 and 9.11, respectively, while the lowest Ns was the value of 2.4 × 10−4 K−1. However, the optimal φ for the largest qref and COP, and for the lowest Ns, were inconsistent, thus, some compromises need be made in the optimization of magnetic refrigerators.

  12. The African Capacity Building Initiative: Toward Improved Policy Analysis and Development Management in Sub-Saharan Africa.

    Science.gov (United States)

    World Bank, Washington, DC.

    The objective of the African Capacity Building Initiative is to build and strengthen local capabilities for policy analysis and development management in Sub-Saharan Africa. This report examines the nature and magnitude of the problem, which basically consists of a shortage of development management skills combined with weakness in the area of…

  13. Refrigeration waste heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    1983-03-01

    UK Super A Stores was built in 1972 and is part of a small indoor shopping complex linked together by a heated mall. The store has a public floor area of approximately 1,232 m{sup 2} (13,261 ft.{sup 2}) and sells the usual variety of food produce including a large selection of frozen foods. There are five lengths of refrigerated display cabinets with a total area of approximately 78 m{sup 2}. There are also some frozen food storage rooms at the back of the store. This report provides a description of a waste heat recovery system within a medium sized food store. It details how the waste heat that is produced by the conventional frozen food display cabinets, can be reused by the store's space heating system. Recommended uses for this waste heat include: diverting to the loading bays which would make the reheat coil unnecessary, diverting to the front of the shop, and heating the adjacent shopping mall. The CREDA (Conservation and Renewable Energy Demonstration Assistance) program contributed $17,444 towards the total project cost of $30,444. The project was initiated by the store owner, who is now realizing a lower annual fuel consumption, with the resulting financial savings. 11 figs., 1 tab.

  14. Salt pill design and fabrication for adiabatic demagnetization refrigerators

    Science.gov (United States)

    Shirron, Peter J.; McCammon, Dan

    2014-07-01

    The performance of an adiabatic demagnetization refrigerator (ADR) is critically dependent on the design and construction of the salt pills that produce cooling. In most cases, the primary goal is to obtain the largest cooling capacity at the low temperature end of the operating range. The realizable cooling capacity depends on a number of factors, including refrigerant mass, and how efficiently it absorbs heat from the various instrument loads. The design and optimization of “salt pills” for ADR systems depend not only on the mechanical, chemical and thermal properties of the refrigerant, but also on the range of heat fluxes that the salt pill must accommodate. Despite the fairly wide variety of refrigerants available, those used at very low temperature tend to be hydrated salts that require a dedicated thermal bus and must be hermetically sealed, while those used at higher temperature - greater than about 0.5 K - tend to be single- or poly-crystals that have much simpler requirements for thermal and mechanical packaging. This paper presents a summary of strategies and techniques for designing, optimizing and fabricating salt pills for both low- and mid-temperature applications.

  15. Salt Pill Design and Fabrication for Adiabatic Demagnetization Refrigerators

    Science.gov (United States)

    Shirron, Peter J.; Mccammon, Dan

    2014-01-01

    The performance of an adiabatic demagnetization refrigerator (ADR) is critically dependent on the design and construction of the salt pills that produce cooling. In most cases, the primary goal is to obtain the largest cooling capacity at the low temperature end of the operating range. The realizable cooling capacity depends on a number of factors, including refrigerant mass, and how efficiently it absorbs heat from the various instrument loads. The design and optimization of "salt pills" for ADR systems depend not only on the mechanical, chemical and thermal properties of the refrigerant, but also on the range of heat fluxes that the salt pill must accommodate. Despite the fairly wide variety of refrigerants available, those used at very low temperature tend to be hydrated salts that require a dedicated thermal bus and must be hermetically sealed, while those used at higher temperature - greater than about 0.5 K - tend to be single-­- or poly-­-crystals that have much simpler requirements for thermal and mechanical packaging. This paper presents a summary of strategies and techniques for designing, optimizing and fabricating salt pills for both low-­- and mid-­-temperature applications.

  16. Building leadership capacity to drive sustainable water management: the evaluation of a customised program.

    Science.gov (United States)

    Taylor, A C

    2010-01-01

    This paper describes a customised, six-month, leadership development program (LDP) that was designed for emerging leaders in the Australian water industry who were promoting sustainable urban water management (SUWM). It also presents results from an evaluation of the program's benefits, costs and overall 'return on investment' (ROI). The program was designed to help build emergent leadership capacity in the water industry, given strong evidence that this form of leadership plays an important role in advancing SUWM. It involved '360-degree feedback' processes, training, individual leadership development plans, and coaching sessions. Its design was informed by a review of the literature, and its content was informed by local empirical research involving effective SUWM leaders. The evaluation used a seven-tier assessment framework that examined different dimensions of the program's performance using source and methodological triangulation. The results indicate that such LDPs can produce a range of positive outcomes, such as promoting desired leadership behaviours and generating a positive ROI estimate. Specifically, the program's estimated ROI was approximately 190% after only one year. The primary conclusion is that evidence-based LDPs which are highly customised for specific types of leaders in the water industry represent a promising type of intervention to build forms of leadership capacity which are needed to successfully promote SUWM.

  17. Flow-synchronous field motion refrigeration

    Science.gov (United States)

    Hassen, Charles N.

    2017-08-22

    An improved method to manage the flow of heat in an active regenerator in a magnetocaloric or an electrocaloric heat-pump refrigeration system, in which heat exchange fluid moves synchronously with the motion of a magnetic or electric field. Only a portion of the length of the active regenerator bed is introduced to or removed from the field at one time, and the heat exchange fluid flows from the cold side toward the hot side while the magnetic or electric field moves along the active regenerator bed.

  18. Capacity building in rural Guatemala by implementing a solid waste management program

    International Nuclear Information System (INIS)

    Zarate, M.A.; Slotnick, J.; Ramos, M.

    2008-01-01

    The development and implementation of a solid waste management program served to build local capacity in San Mateo Ixtatan between 2002 and 2003 as part of a public health action plan. The program was developed and implemented in two phases: (1) the identification and education of a working team from the community; and (2) the completion of a solid waste classification and quantification study. Social capital and the water cycle were two public health approaches utilized to build a sustainable program. The activities accomplished gained support from the community and municipal authorities. A description of the tasks completed and findings of the solid waste classification and quantification performed by a local working group are presented in this paper

  19. A flexible numerical model to study an active magnetic refrigerator for near room temperature applications

    Energy Technology Data Exchange (ETDEWEB)

    Aprea, Ciro; Maiorino, Angelo [Department of Mechanical Engineering, University of Salerno, Via Ponte Don Melillo 1, 84084 Fisciano (Salerno) (Italy)

    2010-08-15

    Magnetic refrigeration is an emerging technology based on the magnetocaloric effect in solid-state refrigerants. This technology offers a smaller global environmental impact than the refrigeration obtained by means of the classical vapor compression machines operating with fluids such as HFCs. The Active Magnetic Regenerative Refrigeration (AMRR) is currently the most studied ant tested magnetic cycle. It combines the regenerative properties of a high specific heat solid porous matrix with the ability of performing thermo-magnetic cycles thanks to the magnetocaloric property of the refrigerant; while a fluid pulsing through the regenerator works as a heat transfer medium. An active magnetic regenerator can provide larger temperature spans making up for the local small temperature variation of the refrigerant. In the present paper, a practical model for predicting the performance and efficiency of an AMRR cycle has been developed. The model evaluates both the refrigerant properties and the entire cycle of an AMR operating in conformity with a Brayton regenerative cycle. The magnetocaloric material of choice is gadolinium, while the heat transfer medium is liquid water. With this model can be predicted the refrigeration capacity, the power consumption and consequently the Coefficient of Performance. The results show a greater COP when compared to a classical vapor compression plant working between the same temperature levels. (author)

  20. A flexible numerical model to study an active magnetic refrigerator for near room temperature applications

    International Nuclear Information System (INIS)

    Aprea, Ciro; Maiorino, Angelo

    2010-01-01

    Magnetic refrigeration is an emerging technology based on the magnetocaloric effect in solid-state refrigerants. This technology offers a smaller global environmental impact than the refrigeration obtained by means of the classical vapor compression machines operating with fluids such as HFCs. The Active Magnetic Regenerative Refrigeration (AMRR) is currently the most studied ant tested magnetic cycle. It combines the regenerative properties of a high specific heat solid porous matrix with the ability of performing thermo-magnetic cycles thanks to the magnetocaloric property of the refrigerant; while a fluid pulsing through the regenerator works as a heat transfer medium. An active magnetic regenerator can provide larger temperature spans making up for the local small temperature variation of the refrigerant. In the present paper, a practical model for predicting the performance and efficiency of an AMRR cycle has been developed. The model evaluates both the refrigerant properties and the entire cycle of an AMR operating in conformity with a Brayton regenerative cycle. The magnetocaloric material of choice is gadolinium, while the heat transfer medium is liquid water. With this model can be predicted the refrigeration capacity, the power consumption and consequently the Coefficient of Performance. The results show a greater COP when compared to a classical vapor compression plant working between the same temperature levels.

  1. Physicians' perceptions of capacity building for managing chronic disease in seniors using integrated interprofessional care models.

    Science.gov (United States)

    Lee, Linda; Heckman, George; McKelvie, Robert; Jong, Philip; D'Elia, Teresa; Hillier, Loretta M

    2015-03-01

    To explore the barriers to and facilitators of adapting and expanding a primary care memory clinic model to integrate care of additional complex chronic geriatric conditions (heart failure, falls, chronic obstructive pulmonary disease, and frailty) into care processes with the goal of improving outcomes for seniors. Mixed-methods study using quantitative (questionnaires) and qualitative (interviews) methods. Ontario. Family physicians currently working in primary care memory clinic teams and supporting geriatric specialists. Family physicians currently working in memory clinic teams (n = 29) and supporting geriatric specialists(n = 9) were recruited as survey participants. Interviews were conducted with memory clinic lead physicians (n = 16).Statistical analysis was done to assess differences between family physician ratings and geriatric specialist ratings related to the capacity for managing complex chronic geriatric conditions, the role of interprofessional collaboration within primary care, and funding and staffing to support geriatric care. Results from both study methods were compared to identify common findings. Results indicate overall support for expanding the memory clinic model to integrate care for other complex conditions. However, the current primary care structure is challenged to support optimal management of patients with multiple comorbidities, particularly as related to limited funding and staffing resources. Structured training, interprofessional teams, and an active role of geriatric specialists within primary care were identified as important facilitators. The memory clinic model, as applied to other complex chronic geriatric conditions, has the potential to build capacity for high-quality primary care, improve health outcomes,promote efficient use of health care resources, and reduce healthcare costs.

  2. Physicians’ perceptions of capacity building for managing chronic disease in seniors using integrated interprofessional care models

    Science.gov (United States)

    Lee, Linda; Heckman, George; McKelvie, Robert; Jong, Philip; D’Elia, Teresa; Hillier, Loretta M.

    2015-01-01

    Abstract Objective To explore the barriers to and facilitators of adapting and expanding a primary care memory clinic model to integrate care of additional complex chronic geriatric conditions (heart failure, falls, chronic obstructive pulmonary disease, and frailty) into care processes with the goal of improving outcomes for seniors. Design Mixed-methods study using quantitative (questionnaires) and qualitative (interviews) methods. Setting Ontario. Participants Family physicians currently working in primary care memory clinic teams and supporting geriatric specialists. Methods Family physicians currently working in memory clinic teams (n = 29) and supporting geriatric specialists (n = 9) were recruited as survey participants. Interviews were conducted with memory clinic lead physicians (n = 16). Statistical analysis was done to assess differences between family physician ratings and geriatric specialist ratings related to the capacity for managing complex chronic geriatric conditions, the role of interprofessional collaboration within primary care, and funding and staffing to support geriatric care. Results from both study methods were compared to identify common findings. Main findings Results indicate overall support for expanding the memory clinic model to integrate care for other complex conditions. However, the current primary care structure is challenged to support optimal management of patients with multiple comorbidities, particularly as related to limited funding and staffing resources. Structured training, interprofessional teams, and an active role of geriatric specialists within primary care were identified as important facilitators. Conclusion The memory clinic model, as applied to other complex chronic geriatric conditions, has the potential to build capacity for high-quality primary care, improve health outcomes, promote efficient use of health care resources, and reduce health care costs. PMID:25932482

  3. Tradeoffs between battery energy capacity and stochastic optimal power management in plug-in hybrid electric vehicles

    International Nuclear Information System (INIS)

    Moura, Scott J.; Fathy, Hosam K.; Stein, Jeffrey L.; Callaway, Duncan S.

    2010-01-01

    Recent results in plug-in hybrid electric vehicle (PHEV) power management research suggest that battery energy capacity requirements may be reduced through proper power management algorithm design. Specifically, algorithms which blend fuel and electricity during the charge depletion phase using smaller batteries may perform equally to algorithms that apply electric-only operation during charge depletion using larger batteries. The implication of this result is that ''blended'' power management algorithms may reduce battery energy capacity requirements, thereby lowering the acquisition costs of PHEVs. This article seeks to quantify the tradeoffs between power management algorithm design and battery energy capacity, in a systematic and rigorous manner. Namely, we (1) construct dynamic PHEV models with scalable battery energy capacities, (2) optimize power management using stochastic control theory, and (3) develop simulation methods to statistically quantify the performance tradeoffs. The degree to which blending enables smaller battery energy capacities is evaluated as a function of both daily driving distance and energy (fuel and electricity) pricing. (author)

  4. Connecting Hydrologic Research and Management in American Samoa through Collaboration and Capacity Building

    Science.gov (United States)

    Shuler, C. K.; El-Kadi, A. I.; Dulai, H.; Glenn, C. R.; Mariner, M. K. E.; DeWees, R.; Schmaedick, M.; Gurr, I.; Comeros, M.; Bodell, T.

    2017-12-01

    In small-island developing communities, effective communication and collaboration with local stakeholders is imperative for successful implementation of hydrologic or other socially pertinent research. American Samoa's isolated location highlights the need for water resource sustainability, and effective scientific research is a key component to addressing critical challenges in water storage and management. Currently, aquifer degradation from salt-water-intrusion or surface-water contaminated groundwater adversely affects much of the islands' municipal water supply, necessitating an almost decade long Boil-Water-Advisory. This presentation will share the approach our research group, based at the University of Hawaii Water Resources Research Center, has taken for successfully implementing a collaboration-focused water research program in American Samoa. Instead of viewing research as a one-sided activity, our program seeks opportunities to build local capacity, develop relationships with key on-island stakeholders, and involve local community through forward-looking projects. This presentation will highlight three applications of collaborative research with water policy and management, water supply and sustainability, and science education stakeholders. Projects include: 1) working with the island's water utility to establish a long-term hydrological monitoring network, motivated by a need for data to parameterize numerical groundwater models, 2) collaboration with the American Samoa Environmental Protection Agency to better understand groundwater discharge and watershed scale land-use impacts for management of nearshore coral reef ecosystems, and 3) participation of local community college and high school students as research interns to increase involvement in, and exposure to socially pertinent water focused research. Through these innovative collaborative approaches we have utilized resources more effectively, and focused research efforts on more pertinent

  5. Analytical computation of thermodynamic performance parameters of actual vapour compression refrigeration system with R22, R32, R134a, R152a, R290 and R1270

    Directory of Open Access Journals (Sweden)

    Vali Shaik Sharmas

    2018-01-01

    Full Text Available The present work focuses on analytical computation of thermodynamic performance of actual vapour compression refrigeration system by using six pure refrigerants. The refrigerants are namely R22, R32, R134a, R152a, R290 and R1270 respectively. A MATLAB code is developed to compute the thermodynamic performance parameters of actual vapour compression system such as refrigeration effect, compressor work, COP, power per ton of refrigeration, compressor discharge temperature and volumetric refrigeration capacity at condensing and evaporating temperatures of 54.4oC and 7.2oC respectively. Analytical results exhibited that COP of both R32 and R134a are 15.95% and 11.71% higher among the six investigated refrigerants. However R32 and R134a cannot be replaced directly into R22 system. This is due to their higher compressor discharge temperature and poor volumetric capacity respectively. The discharge temperature of both R1270 and R290 are lower than R22 by 20-26oC. Volumetric refrigeration capacity of R1270 (3197 kJ/m3 is very close to that of volumetric capacity of R22 (3251 kJ/m3. Both R1270 and R290 shows good miscibility with R22 mineral oil. Overall R1270 would be a suitable ecofriendly refrigerant to replace R22 from the stand point of ODP, GWP, volumetric capacity, discharge temperature and miscibility with mineral oil although its COP is lower.

  6. Synchronous temperature rate control and apparatus for refrigeration with reduced energy consumption

    Science.gov (United States)

    Gomes, Alberto Regio; Keres, Stephen L.; Kuehl, Steven J.; Litch, Andrew D.; Richmond, Peter J.; Wu, Guolian

    2015-09-22

    A refrigerator appliance configuration, and associated methods of operation, for an appliance with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper, and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The controller, by operation of the compressor, fans, damper and/or valve system, depending on the appliance configuration, synchronizes alternating cycles of cooling each compartment to a temperature approximately equal to the compartment set point temperature.

  7. The cost of solar refrigeration: The rococo project; Was solare Kuehlung kostet - das Rococo-Projekt

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, J.P.

    2008-01-21

    The cost of modern solar refrigerators is between 1,300 and 8,000 Euros per kW of refrigeration capacity. The biggest potential for savings is in the peripheral components, as well as in the operating cost and especially in servicing. Cost reduction must have priority if solar refrigeration is to be successful in the market. In the context of the European research project ''Reduction of costs of Solar Cooling systems'' (Rococo), a team of scientists from France, Spain and Austria investigated existing systems. (orig.)

  8. Performance Characteristics of a Refrigerator-Freezer with Parallel Evaporators using a Linear Compressor

    OpenAIRE

    Min, Byungchae; Song, Sangjin; Noh, Kiyoul; Kim, Geonwoo; Yoon, Teaseung; Na, Sangkyung; Song, Sanghoon; Yang, Jangsik; Choi, Gyungmin; Kim, Duckjool

    2016-01-01

    A linear compressor for a domestic refrigerator-freezer has energy saving potential compared with a reciprocating compressor because of a low friction loss and free piston system. A linear compressor can control the piston stroke since it does not have mechanical restriction of piston movement. Therefore, the energy consumption of a domestic refrigerator-freezer using a linear compressor can be reduced by changing the cooling capacity of the compressor. In order to investigate the performance...

  9. Measured Performance of Four New 18 kW@4.5 K Helium Refrigerators for the LHC Cryogenic System

    CERN Document Server

    Gruehagen, Henning

    2005-01-01

    The cryogenic system for the Large Hadron Collider (LHC) under construction at CERN will include four new 4.5 K-helium refrigerators, to cover part of the cooling needs of the LHC at the 4.5-20 K and 50-75 K levels. Two refrigerators are delivered by Air Liquide, France, and two by Linde Kryotechnik, Switzerland. During the last three years, all four refrigerators have been installed and commissioned at four different points along the LHC. The specified requirements of the refrigerators are presented, with special focus on the capacities at the various temperature levels. The capacities of the refrigerators were measured using a dedicated test cryostat, and the measured performance for all four installations is presented, and compared to the guaranteed performance in the original proposal of the suppliers. Finally, the process design of the two supplies is compared, and their differences and similarities briefly analysed.

  10. Krypton based adsorption type cryogenic refrigerator

    Science.gov (United States)

    Jones, Jack A. (Inventor); Schember, Helene R. (Inventor)

    1989-01-01

    Krypton and a monolithic porous carbon such as Saran carbon are used respectively as the sorbate and sorbent of an adsorption type refrigerator to improve refrigeration efficiency and operational longevity.

  11. REDUCING REFRIGERANT EMISSIONS FROM SUPERMARKET SYSTEMS

    Science.gov (United States)

    Large refrigeration systems are found in several applications including supermarkets, cold storage warehouses, and industrial processes. The sizes of these systems are a contributing factor to their problems of high refrigerant leak rates because of the thousands of connections, ...

  12. Thermoelectric refrigerator having improved temperature stabilization means

    International Nuclear Information System (INIS)

    Falco, C.M.

    1982-01-01

    A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized

  13. Load forecasting for supermarket refrigeration

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Aalborg Nielsen, Henrik

    This report presents a study of models for forecasting the load for supermarket refrigeration. The data used for building the forecasting models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. The load for refrigeration is the sum of all cabinets in the supermarket, both low and medium temperature cabinets, and spans a period of one year. As input to the forecasting models the ambient temperature observed near the supermarket together with weather forecasts are used. Every hour...

  14. The influence of capacity management on the unit cost of production: a case study in a flexible plastic packaging company

    Directory of Open Access Journals (Sweden)

    Tálita Floriano Goulart Silva

    2013-08-01

    Full Text Available This article presents the relationship between capacity management and cost management in determining the unit cost. The objective was to show how the use of effective capacity decreases the unit cost of manufacturing. For this, follow these steps: 1 Knowledge and analysis of production process and PPPC; 2 Data Collection; 3 Application of the Method Cost Center; 4Verification of the relationship between the Capacity Management and Cost Management. Through the company’s accounting reports, observations and interviews, the following results was possible: knowledge of the production process and functioning of PPCP, measuring the cost of each step of the production process and the unit cost of each product. Subsequently, we compared the unit cost using the effective capacity and normal capacity. The results showed that the unit costs decrease with the use of effective capacity, while increasing the margin for each product, even with the lower sale price, thus establishing a virtuous circle: effective capacity utilization, reduced unit cost, most competitive prices and increase in the number of requests.

  15. A passive solar heater-refrigerator

    International Nuclear Information System (INIS)

    D'Isep, F.; Sertorio, L.

    1983-01-01

    In this paper it is studied the nonequilibrium thermodynamic steady-state behaviour of a model system representing a core surrounded by an envelope in which the envelope interacts with the solar radiation and with an external bath having a given temperature profile. The heat flow between core and envelope can be controlled by varying the thermal conductivity of their interface. It is shown that this system acts as a passive heat pump raising the core average temperature with respect to the average equilibrium value corresponding to a fixed value of the interface conductivity, at the same time flattening its oscillation in time. By changing the time dependence of the conductivity the system vice versa acts as a refrigerator. It is shown how the limits of this performance depend on the passive parameters such as surfaces, conductivities, heat capacities. The periodicity considered in this study is the daily cycle

  16. Coefficient of performance of Stirling refrigerators

    Science.gov (United States)

    E Mungan, Carl

    2017-09-01

    Stirling coolers transfer heat in or out of the working fluid during all four stages of their operation, and their coefficient of performance depends on whether the non-isothermal heat exchanges are performed reversibly or irreversibly. Both of these possibilities can in principle be arranged. Notably, if the working fluid is an ideal gas, the input of energy in the form of heat during one isochoric step is equal in magnitude to the output during the other isochoric step in the cycle. The theoretical performance of the fridge can then attain the reversible Carnot limit if a regenerator is used, which is a high heat capacity material through which the gas flows. Various Stirling refrigerator configurations are analysed in this article at a level of presentation suitable for an introductory undergraduate thermodynamics course.

  17. Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

    Science.gov (United States)

    Rasta, IM; Susila, IDM; Subagia, IWA

    2018-01-01

    The application of refrigeration technology to postharvest fishery products is an very important. Moreover, Indonesia is a tropical region with relatively high temperatures. Fish storage age can be prolonged with a decrease in temperature. Frozen fish can even be stored for several months. Fish freezing means preparing fish for storage in low-temperature cold storage. The working fluid used in cold storage to cool low-temperature chambers and throw heat into high-temperature environments is refrigerant. So far refrigerant used in cold storage is Hydrochloroflourocarbons (HCFC) that is R-22. Chlor is a gas that causes ODP (Ozone Depleting Potential), while Flour is a gas that causes GWP (Global Warming Potential). Government policy began in 2015 to implement Hydrochloroflourocarbons Phase-Out Management Plan. Hydrocarbon (HC) is an alternative substitute for R-22. HC-22 (propane ≥ 99.5%) has several advantages, among others: environmentally friendly, indicated by a zero ODP value, and GWP = 3 (negligible), thermophysical property and good heat transfer characteristics, vapor phase density Which is low, and good solubility with mineral lubricants. The use of HC-22 in cold storage is less than R-22. From the analysis results obtained, cold storage system using HC-22 has better performance and energy consumption is more efficient than the R-22.

  18. Refrigeration Cycle Design for Refrigerant Mixtures by Molecular Simulation

    Czech Academy of Sciences Publication Activity Database

    Smith, W.R.; Francová, Magda; Kowalski, M.; Nezbeda, Ivo

    2010-01-01

    Roč. 75, č. 4 (2010), s. 383-391 ISSN 0010-0765 R&D Projects: GA AV ČR IAA400720710 Grant - others:NSERC(CA) OGP1041 Institutional research plan: CEZ:AV0Z40720504 Keywords : refrigerants * molecular simulation s * vapor–liquid equilibrium Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.853, year: 2010

  19. Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU

    International Nuclear Information System (INIS)

    Ganni, V.; Knudsen, P.; Arenius, D.; Casagrande, F.

    2014-01-01

    The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab’s suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system

  20. 49 CFR 173.174 - Refrigerating machines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Refrigerating machines. 173.174 Section 173.174 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Refrigerating machines. A refrigerating machine assembled for shipment and containing 7 kg (15 pounds) or less...

  1. Solar Refrigerators Store Life-Saving Vaccines

    Science.gov (United States)

    2014-01-01

    Former Johnson Space Center engineer David Bergeron used his experience on the Advanced Refrigeration Technology Team to found SunDanzer Refrigeration Inc., a company specializing in solar-powered refrigerators. The company has created a battery-free unit that provides safe storage for vaccines in rural and remote areas around the world.

  2. Land-based approach to evaluate sustainable land management and adaptive capacity of ecosystems/lands

    Science.gov (United States)

    Kust, German; Andreeva, Olga

    2015-04-01

    A number of new concepts and paradigms appeared during last decades, such as sustainable land management (SLM), climate change (CC) adaptation, environmental services, ecosystem health, and others. All of these initiatives still not having the common scientific platform although some agreements in terminology were reached, schemes of links and feedback loops created, and some models developed. Nevertheless, in spite of all these scientific achievements, the land related issues are still not in the focus of CC adaptation and mitigation. The last did not grow much beyond the "greenhouse gases" (GHG) concept, which makes land degradation as the "forgotten side of climate change" The possible decision to integrate concepts of climate and desertification/land degradation could be consideration of the "GHG" approach providing global solution, and "land" approach providing local solution covering other "locally manifesting" issues of global importance (biodiversity conservation, food security, disasters and risks, etc.) to serve as a central concept among those. SLM concept is a land-based approach, which includes the concepts of both ecosystem-based approach (EbA) and community-based approach (CbA). SLM can serve as in integral CC adaptation strategy, being based on the statement "the more healthy and resilient the system is, the less vulnerable and more adaptive it will be to any external changes and forces, including climate" The biggest scientific issue is the methods to evaluate the SLM and results of the SLM investments. We suggest using the approach based on the understanding of the balance or equilibrium of the land and nature components as the major sign of the sustainable system. Prom this point of view it is easier to understand the state of the ecosystem stress, size of the "health", range of adaptive capacity, drivers of degradation and SLM nature, as well as the extended land use, and the concept of environmental land management as the improved SLM approach

  3. Multiple Carrying Capacities from a management-oriented perspective to operationalize sustainable tourism in protected areas.

    Science.gov (United States)

    Salerno, Franco; Viviano, Gaetano; Manfredi, Emanuela C; Caroli, Paolo; Thakuri, Sudeep; Tartari, Gianni

    2013-10-15

    This article describes how the concept of Tourism Carrying Capacity (TCC) has shifted from a uni-dimensional approach to incorporating environmental, social and political aspects. This shift is demonstrated by a study of a large, internationally popular protected area used by trekkers, the Mt. Everest Region, where qualitative data collected from visitors was combined with environmental modeling using a participatory framework. Tourist satisfaction showed positive margins for further tourist industry expansion, but current environmental conditions limit growth and further development. Space and time dimensions were also considered. We observed that the limits on growth and further development can be manipulated, with a certain degree of flexibility, through investments and regulatory measures. We hypothesized that TCC can play an important role in the management of protected areas only if it is viewed as a systematic, strategic policy tool within a planning process rather than as a unique, intrinsic number that is not modifiable. We conclude that to translate the strategy into action using standard measures, further investigation is needed to balance the various TCC components as a part of a decision-making framework that includes the integration of different cultural approaches and policy needs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. High Efficiency, Low Emission Refrigeration System

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

    2016-08-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for

  5. Solar-Powered Refrigeration System

    Science.gov (United States)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  6. Magnetic refrigerator for hydrogen liquefaction

    Energy Technology Data Exchange (ETDEWEB)

    Numazawa, T [National Institute for Materials Science, Tsukuba (Japan); Kamlya, K. [Japan Atomic Energy Agency, Naka (Japan); Utaki, T. [Osaka University, Osaka (Japan); Matsumoto, K. [Kanazawa University, Kanazawa (Japan)

    2013-06-15

    This paper reviews the development status of magnetic refrigeration system for hydrogen liquefaction. There is no doubt that hydrogen is one of most important energy sources in the near future. In particular, liquid hydrogen can be utilized for infrastructure construction consisting of storage and transportation. Liquid hydrogen is in cryogenic temperatures and therefore high efficient liquefaction method must be studied. Magnetic refrigeration which uses the magneto-caloric effect has potential to realize not only the higher liquefaction efficiency > 50 %, but also to be environmentally friendly and cost effective. Our hydrogen magnetic refrigeration system consists of Carnot cycle for liquefaction stage and AMR (active magnetic regenerator) cycle for precooling stages. For the Carnot cycle, we develop the high efficient system > 80 % liquefaction efficiency by using the heat pipe. For the AMR cycle, we studied two kinds of displacer systems, which transferred the working fluid. We confirmed the AMR effect with the cooling temperature span of 12 K for 1.8 T of the magnetic field and 6 second of the cycle. By using the simulation, we estimate the total efficiency of the hydrogen liquefaction plant for 10 kg/day. A FOM of 0.47 is obtained in the magnetic refrigeration system operation temperature between 20 K and 77 K including LN2 work input.

  7. Stability of split Stirling refrigerators

    NARCIS (Netherlands)

    Waele, de A.T.A.M.; Liang, W.

    2009-01-01

    In many thermal systems spontaneous mechanical oscillations are generated under the influence of large temperature gradients. Well-known examples are Taconis oscillations in liquid-helium cryostats and oscillations in thermoacoustic systems. In split Stirling refrigerators the compressor and the

  8. Communication between Participants and Non-Participants in Analytical Capacity Building Projects: Management Advice to Family Farms in Benin

    Science.gov (United States)

    Rouchouse, Marine; Faysse, Nicolas; De Romemont, Aurelle; Moumouni, Ismail; Faure, Guy

    2015-01-01

    Purpose: Approaches to build farmers' analytical capacities are said to trigger wide-ranging changes. This article reports on the communication process between participants and non-participants in one such approach, related to the technical and management skills learned by participants and the changes these participants subsequently made, and the…

  9. Control of the Tevatron Satellite Refrigeration system

    International Nuclear Information System (INIS)

    Theilacker, J.; Chapman, L.; Gannon, J.; Hentges, M.; Martin, M.; Rode, C.H.; Zagel, J.

    1984-01-01

    This chapter describes a computerized control system for 24 satellite refrigerators which cool a six kilometer ring of superconducting magnets. The control system consists of 31 independent microprocessors operating over 400 servo loops, and a central computer system which provides monitoring, alarms, logging and changing of parameters. Topics considered include pressure measurement, flow measurement, temperature measurement, gas analysis, control valves, expansion engine controllers, and control loops. Each refrigerator has 12 active microprocessor based control loops which tune the refrigerator to one of its four operating modes: satellite, liquefier, refrigerator, and stand-by. It is suggested that optimizing the refrigerator control loops and quench recovery scheme will minimize the accelerator down time

  10. Efficiency improvement of commercial refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Denecke, Julius [NTNU, Trondheim (Norway); Hafner, Armin [SINTEF Energy Research, Trondheim (Norway)

    2011-07-01

    This work presents a historical review of carbon dioxide refrigeration systems. Further a literature survey is carried out to get a status of existing refrigeration technology related to supermarkets. In the next step various energy saving options are stated. A heat recovery model, basing on a R744 booster refrigeration system is established and described. Simplified demand curves for refrigeration, air conditioning and heating will base this model to calculate different heat recovery layouts. Supermarket future trends will be considered and integrated in the calculation. Finally the calculated energy consumptions will be compared with real energy consumptions of selected supermarket refrigeration systems.

  11. Demand Response Opportunities in Industrial Refrigerated Warehouses in California

    Energy Technology Data Exchange (ETDEWEB)

    Goli, Sasank; McKane, Aimee; Olsen, Daniel

    2011-06-14

    Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

  12. Experimental investigation of a thermoacoustic-Stirling refrigerator driven by a thermoacoustic-Stirling heat engine.

    Science.gov (United States)

    Luo, E C; Dai, W; Zhang, Y; Ling, H

    2006-12-22

    In this paper, a thermally-driven thermoacoustic refrigerator system without any moving part is reported. This refrigeration system consists of a thermoacoustic-Stirling heat engine and a thermoacoustic-Stirling refrigerator; that is, the former is the driving source for the latter. Both the subsystems are designed to operate on traveling-wave mode. In the experiment, it was found that the DC-flows had significant negative effect on the heat engine and the refrigerator. To suppress these DC-flows, two flexible membranes were inserted into the two subsystems and worked very well. Then extensive experiments were made to test the influence of different parameters on refrigeration performance of the whole system. The system has so far achieved a no-load temperature of -65 degrees C, a cooling capacity of about 270 W at -20 degrees C and 405 W at 0 degrees C; in fact, the result showed a good prospect of the refrigeration system in room-temperature cooling such as food refrigeration and air-conditioning.

  13. Demonstration of the Use of Remote Temperature Monitoring Devices in Vaccine Refrigerators in Haiti.

    Science.gov (United States)

    Cavallaro, Kathleen F; Francois, Jeannot; Jacques, Roody; Mentor, Derline; Yalcouye, Idrissa; Wilkins, Karen; Mueller, Nathan; Turner, Rebecca; Wallace, Aaron; Tohme, Rania A

    After the 2010 earthquake, Haiti committed to introducing 4 new antigens into its routine immunization schedule, which required improving its cold chain (ie, temperature-controlled supply chain) and increasing vaccine storage capacity by installing new refrigerators. We tested the feasibility of using remote temperature monitoring devices (RTMDs) in Haiti in a sample of vaccine refrigerators fueled by solar panels, propane gas, or electricity. We analyzed data from 16 RTMDs monitoring 24 refrigerators in 15 sites from March through August 2014. Although 5 of the 16 RTMDs exhibited intermittent data gaps, we identified typical temperature patterns consistent with refrigerator door opening and closing, propane depletion, thermostat insufficiency, and overstocking. Actual start-up, annual maintenance, and annual electricity costs for using RTMDs were $686, $179, and $9 per refrigerator, respectively. In Haiti, RTMD use was feasible. RTMDs could be prioritized for use with existing refrigerators with high volumes of vaccines and new refrigerators to certify their functionality before use. Vaccine vial monitors could provide additional useful information about cumulative heat exposure and possible vaccine denaturation.

  14. Investigation of waste heat recovery of binary geothermal plants using single component refrigerants

    Science.gov (United States)

    Unverdi, M.

    2017-08-01

    In this study, the availability of waste heat in a power generating capacity of 47.4 MW in Germencik Geothermal Power Plant has been investigated via binary geothermal power plant. Refrigerant fluids of 7 different single components such as R-134a, R-152a, R-227ea, R-236fa, R-600, R-143m and R-161 have been selected. The binary cycle has been modeled using the waste heat equaling to mass flow rate of 100 kg/s geothermal fluid. While the inlet temperature of the geothermal fluid into the counter flow heat exchanger has been accepted as 110°C, the outlet temperature has been accepted as 70°C. The inlet conditions have been determined for the refrigerants to be used in the binary cycle. Finally, the mass flow rate of refrigerant fluid and of cooling water and pump power consumption and power generated in the turbine have been calculated for each inlet condition of the refrigerant. Additionally, in the binary cycle, energy and exergy efficiencies have been calculated for 7 refrigerants in the availability of waste heat. In the binary geothermal cycle, it has been found out that the highest exergy destruction for all refrigerants occurs in the heat exchanger. And the highest and lowest first and second law efficiencies has been obtained for R-600 and R-161 refrigerants, respectively.

  15. Thermodynamic analysis of refrigerant mixtures for possible replacements for CFCs by an algorithm compiling property data

    International Nuclear Information System (INIS)

    Arcaklioglu, Erol; Cavusoglu, Abdullah; Erisen, Ali

    2006-01-01

    In this study, we formed an algorithm to find refrigerant mixtures of equal volumetric cooling capacity (VCC) when compared to CFC based refrigerants in vapor compression refrigeration systems. To achieve this aim the point properties of the refrigerants are obtained from REFPROP where appropriate. We used replacement mixture ratios-of varying mass percentages-suggested by various authors along with our newly formed mixture ratios. In other words, we tried to see the effect of changing mass percentages of the suggested (i.e. in the literature) replacement refrigerants on the VCC of the cooling system. Secondly, we used this algorithm to calculate the coefficient of performance (COP) of the same refrigeration system. This mechanism has provided us the ability to compare the COP of the suggested refrigerant mixtures and our newly formed mixture ratios with the conventional CFC based ones. According to our results, for R12 R290/R600a (56/44) mixture, for R22 R32/R125/R134a (32.5/5/62.5) mixture, and for R502 R32/R125/R134a (43/5/52) mixture are appropriate and can be used as replacements

  16. Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

    International Nuclear Information System (INIS)

    Ardhapurkar, P. M.; Sridharan, Arunkumar; Atrey, M. D.

    2014-01-01

    A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends on the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models

  17. Effects of hysteresis and Brayton cycle constraints on magnetocaloric refrigerant performance

    Science.gov (United States)

    Brown, T. D.; Buffington, T.; Shamberger, P. J.

    2018-05-01

    Despite promising proofs of concept, system-level implementation of magnetic refrigeration has been critically limited by history-dependent refrigerant losses that interact with governing thermodynamic cycles to adversely impact refrigeration performance. Future development demands a more detailed understanding of how hysteresis limits performance, and of how different types of cycles can mitigate these limitations, but without the extreme cost of experimental realization. Here, the utility of Brayton cycles for magnetic refrigeration is investigated via direct simulation, using a combined thermodynamic-hysteresis modeling framework to compute the path-dependent magnetization and entropy of a model alloy for a variety of feasible Brayton cycles between 0-1.5 T and 0-5 T. By simultaneously varying the model alloy's hysteresis properties and applying extensions of the thermodynamic laws to non-equilibrium systems, heat transfers and efficiencies are quantified throughout the space of hystereses and Brayton cycles and then compared with a previous investigation using Ericsson cycles. It is found that (1) hysteresis losses remain a critical obstacle to magnetic refrigeration implementation, with efficiencies >80% in the model system requiring hysteresis refrigerant transformation temperatures at the relevant fields; (3) for a given hysteresis and field constraint, Brayton and Ericsson-type cycles generate similar efficiencies; for a given temperature span, Ericsson cycles lift more heat per cycle, with the difference decreasing with the refrigerant heat capacity outside the phase transformation region.

  18. Overall performance of the duplex Stirling refrigerator

    International Nuclear Information System (INIS)

    Erbay, L. Berrin; Ozturk, M. Mete; Doğan, Bahadır

    2017-01-01

    Highlights: • Overall performance coefficient of duplex Stirling refrigerator was investigated. • A definite region for the coefficient of performance of the refrigerator in duplex Stirling is identified. • A definite region for the thermal efficiency of the heat engine in duplex Stirling is identified. • Benchmark values and design bounds of the duplex Stirling refrigerator were obtained. - Abstract: The duplex Stirling refrigerator is an integrated refrigerator consists of Stirling cycle engine and Stirling cycle refrigerator used for cooling. The equality of the work generation of the heat engine to the work consumption of the refrigerator is the primary constraint of the duplex Stirling. The duplex Stirling refrigerator is investigated thermodynamically by considering the effects of constructional and operational parameters which are namely the temperature ratios for heat engine and refrigerator, and the compression ratios for both sides. The primary concern is given to the parametric effects on the overall coefficient of performance of the duplex Stirling refrigerator. The given diagrams provide a design bounds and benchmark results that allows seeing the big picture about the cooling load and heat input relation. Moreover they ease to determine the corresponding work rate to the target cooling load. As regard to the obtained results, a definite region for coefficient of performance of the refrigerator and a definite region for the thermal efficiency of the heat engine of the duplex Stirling are identified.

  19. Environment-friendly refrigeration - Switzerland moves forward

    International Nuclear Information System (INIS)

    Stohler, F.

    2003-01-01

    This article presents an interview with Silvan Schaller, president of the Swiss Refrigeration Society SVK and head of a leading Swiss industrial refrigeration company, on the subject of the implementation of new Swiss materials legislation that regulates the use of various refrigerants. In particular, the co-operation between the Society and the regulatory authorities is stressed. The reasons behind the regulations - the protection of the environment and, in particular, the ozone layer - are discussed as are the efforts required by industry to meet them. Future refrigeration technologies and the choice of refrigerants are examined. Measures that will have to be taken by the companies in the refrigeration sector, such as the additional training of personnel and the monitoring of the disposal of wastes, are examined. For the future, the goal of reducing the energy consumption of refrigeration installations is noted

  20. Magnon-driven quantum dot refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuan; Huang, Chuankun; Liao, Tianjun; Chen, Jincan, E-mail: jcchen@xmu.edu.cn

    2015-12-18

    Highlights: • A three-terminal quantum dot refrigerator is proposed. • The effects of magnetic field, applied voltage, and polarization are considered. • The region that the system can work as a refrigerator is determined. • Two different magnon-driven quantum dot refrigerators are compared. - Abstract: A new model of refrigerator consisting of a spin-splitting quantum dot coupled with two ferromagnetic reservoirs and a ferromagnetic insulator is proposed. The rate equation is used to calculate the occupation probabilities of the quantum dot. The expressions of the electron and magnon currents are obtained. The region that the system can work in as a refrigerator is determined. The cooling power and coefficient of performance (COP) of the refrigerator are derived. The influences of the magnetic field, applied voltage, and polarization of two leads on the performance are discussed. The performances of two different magnon-driven quantum dot refrigerators are compared.

  1. Miniaturized Air-to-Refrigerant Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Radermacher, Reinhard [Univ. of Maryland, College Park, MD (United States); Bacellar, Daniel [Univ. of Maryland, College Park, MD (United States); Aute, Vikrant [Univ. of Maryland, College Park, MD (United States); Huang, Zhiwei [Univ. of Maryland, College Park, MD (United States); Hwang, Yunho [Univ. of Maryland, College Park, MD (United States); Ling, Jiazhen [Univ. of Maryland, College Park, MD (United States); Muehlbauer, Jan [Univ. of Maryland, College Park, MD (United States); Tancabel, James [Univ. of Maryland, College Park, MD (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Zhang, Mingkan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-23

    which met project requirements. Attempts to prototype a 10kW have presented unique manufacturing challenges, especially regarding tube blockages and structural stability. DP III comprised optimizing two-phase HX’s for a 3.0Ton capacity in a heat pump / air-conditioning unit for cooling mode application using R410A as the working fluid. The HX’s theoretically address the project requirements. System-level analysis showed the HX’s achieved up to 15% improvement in COP while also reducing overall unit charge by 30-40%. The project methodology was capable of developing HX’s which can outperform current state-of-the-art MCHX by at least 20% reduction in volume, material volume, and approach temperature. Additionally, the capability for optimization using refrigerant charge as an objective function was developed. The five-year manufacturing feasibility of the proposed HX’s was shown to have a good outlook. Successful prototyping through both conventional manufacturing methods and next generation methods such as additive manufacturing was achieved.

  2. Cooling load and coefficient of performance optimizations for real air-refrigerators

    International Nuclear Information System (INIS)

    Tu Youming; Chen Lingen; Sun Fengrui; Wu Chih

    2006-01-01

    Based on a simple irreversible variable-temperature heat reservoir air (Brayton) refrigeration cycle model, a performance analysis and optimization of a real air refrigerator is carried out using finite-time thermodynamics. To maximize the cooling load and the coefficient of performance (COP) of the cycle, the allocation of a fixed total heat-exchanger inventory and thermal-capacity rate matching between the working fluid and heat reservoirs are optimized, respectively. The influences of pressure ratio, the total heat-exchanger inventory, the efficiencies of the compressor and expander, the thermal capacity rate of the working fluid and the ratio of the thermal-capacity rates of the heat reservoirs on the performance of the cycle are shown by numerical examples. The results obtained provide guidances for the design of practical air-refrigeration plants

  3. The 4.5K refrigerators for the LHC are all present and correct!

    CERN Document Server

    2004-01-01

    Acceptance procedures for the last of the LHC 4.5 K refrigerators have been completed at Point 6. All that now remains to be done, to have the LHC refrigeration system ready by the end of 2005, is to upgrade the refrigerators recovered from LEP and install the 1.8 K cooling system. By now you will be well aware that the LHC's superconducting magnets cannot operate unless they are cooled to 1.8 K (-271°C) (see Bulletin 13-14/2002). Eight 4.5 K refrigerators, one for each sector of the LHC, are required to achieve this. In December last year the last of these refrigerators, specially designed for the LHC, was accepted at Point 6. "It is a big step forwards for the LHC's refrigeration system, as it takes its cooling capacity at 4.5 K to 140 kW, that is to say almost 40,000 litres of liquid helium per hour, a capacity never previously attained. The progress achieved since the days of LEP is impressive, particularly if one bears in mind the extent of the infrastructure required, " (see...

  4. A system dynamic modeling approach for evaluating municipal solid waste generation, landfill capacity and related cost management issues

    International Nuclear Information System (INIS)

    Kollikkathara, Naushad; Feng Huan; Yu Danlin

    2010-01-01

    As planning for sustainable municipal solid waste management has to address several inter-connected issues such as landfill capacity, environmental impacts and financial expenditure, it becomes increasingly necessary to understand the dynamic nature of their interactions. A system dynamics approach designed here attempts to address some of these issues by fitting a model framework for Newark urban region in the US, and running a forecast simulation. The dynamic system developed in this study incorporates the complexity of the waste generation and management process to some extent which is achieved through a combination of simpler sub-processes that are linked together to form a whole. The impact of decision options on the generation of waste in the city, on the remaining landfill capacity of the state, and on the economic cost or benefit actualized by different waste processing options are explored through this approach, providing valuable insights into the urban waste-management process.

  5. U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys

    Energy Technology Data Exchange (ETDEWEB)

    Greenblatt, Jeffery B.; Young, Scott J.; Yang, Hung-Chia; Long, Timothy; Beraki, Bereket; Price, Sarah K.; Pratt, Stacy; Willem, Henry; Desroches, Louis-Benoit

    2013-11-14

    Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,981 clean survey responses were obtained from five distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 4.4(–2.7,+2.3) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated

  6. U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys

    Energy Technology Data Exchange (ETDEWEB)

    Greenblatt, Jeffery B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Young, Scott J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yang, Hung-Chia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Long, Timothy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Beraki, Bereket [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Sarah K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Pratt, Stacy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Willem, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Desroches, Louis-Benoit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,820 clean survey responses were obtained from four distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 2.9(–2.5,+4.5) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated

  7. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.

    Science.gov (United States)

    Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y

    2017-04-19

    Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published

  8. Bridging the Water Policy and Management Silos: An Opportunity for Leveraged Capacity Building

    Science.gov (United States)

    Wegner, D. L.

    2017-12-01

    The global community is challenged by increasing demand and decreasing water supplies. Historically nations have focused on local or regional water development projects that meet specific needs, often without consideration of the impact on downstream transboundary water users or the watershed itself. Often these decisions have been based on small sets of project specific data with little assessment on river basin impacts. In the United States this disjointed approach to water has resulted in 26 federal agencies having roles in water management or regulation, 50 states addressing water rights and compliance, and a multitude of tribal and local entities intersecting the water process. This approach often manifests itself in a convoluted, disjointed and time-consuming approach. The last systematic and comprehensive review of nationwide water policy was the 1973 National Water Commission Report. A need exists for capacity building collaborative and integrative leadership and dialogue. NASA's Western Water Applications Office (WWAO) provides a unique opportunity to leverage water and terrain data with water agencies and policy makers. A supported WWAO can provide bridges between federal and state water agencies; provide consistent integrated hydrologic and terrain based data set acquired from multiple earth orbiting satellites and airborne platforms; provide data sets leveraged with academic and research based entities to develop specific integrative predictive tools; and evaluate hydrology information across multiple boundaries. It is the author's conclusion that the Western Water Applications Office can provide a value-added approach that will help translate transboundary water and earth terrain information to national policy decisions through education, increased efficiency, increased connectivity, improved coordination, and increased communication. To be effective the WWAO should embrace five objectives: (1) be technically and scientifically valid; (2

  9. Control of Refrigeration Systems for Trade-off between Energy Consumption and Food Quality Loss

    DEFF Research Database (Denmark)

    Cai, Junping

    In supermarkets, control strategies determine both the energy consumption of refrigeration systems and the quality loss of refrigerated foodstuffs. The question is, what can be done to optimize the balance between quality loss and energy consumption? This thesis tries to answer this question...... by applying two main optimization strategies to traditional refrigeration systems. The first strategy is a new defrost-on-demand scheme, which based on an objective function between quality loss and energy consumption, continuously seeks an optimal time interval for defrosting in dynamic situation. The second...... strategy is through utilization of the thermal mass of the refrigerated foodstuffs, the day-night temperature variation and the capacity control of the compressor, to realize a trade-off between system energy consumption and food quality loss....

  10. eLearning for health system leadership and management capacity building: a protocol for a systematic review.

    Science.gov (United States)

    Tudor Car, Lorainne; Atun, Rifat

    2017-08-21

    Health leadership and management capacity are essential for health system strengthening and for attaining universal health coverage by optimising the existing human, technological and financial resources. However, in health systems, health leadership and management training is not widely available. The use of information technology for education (ie, eLearning) could help address this training gap by enabling flexible, efficient and scalable health leadership and management training. We present a protocol for a systematic review on the effectiveness of eLearning for health leadership and management capacity building in improving health system outcomes. We will follow the Cochrane Collaboration methodology. We will search for experimental studies focused on the use of any type of eLearning modality for health management and leadership capacity building in all types of health workforce cadres. The primary outcomes of interest will be health outcomes, financial risk protection and user satisfaction. In addition, secondary outcomes of interest include the attainment of health system objectives of improved equity, efficiency, effectiveness and responsiveness. We will search relevant databases of published and grey literature as well as clinical trials registries from 1990 onwards without language restrictions. Two review authors will screen references, extract data and perform risk of bias assessment independently. Contingent on the heterogeneity of the collated literature, we will perform either a meta-analysis or a narrative synthesis of the collated data. The systematic review will aim to inform policy makers, investors, health professionals, technologists and educators about the existing evidence, potential gaps in literature and the impact of eLearning for health leadership and management capacity building on health system outcomes. We will disseminate the review findings by publishing it as a peer-reviewed journal manuscript and conference abstracts. PROSPERO CRD

  11. Modifications to JLab 12 GeV Refrigerator and Wide Range Mix Mode Performance Testing Results

    Science.gov (United States)

    Knudsen, P.; Ganni, V.; Hasan, N.; Dixon, K.; Norton, R.; Creel, J.

    2017-02-01

    Analysis of data obtained during the spring 2013 commissioning of the new 4.5 K refrigeration system at Jefferson Lab (JLab) for the 12 GeV upgrade indicated a wide capacity range with good efficiency and minimal operator interaction. Testing also showed that the refrigerator required higher liquid nitrogen (LN) consumption for its pre-cooler than anticipated by the design. This does not affect the capacity of the refrigerator, but it does result in an increased LN utility cost. During the summer of 2015 the modifications were implemented by the cold box manufacturer, according to a design similar to the JLab 12 GeV cold box specification. Subsequently, JLab recommissioned the cold box and performed extensive performance testing, ranging from 20% to 100% of the design maximum capacity, and in various modes of operation, ranging from pure refrigeration, pure liquefaction, half-and-half mix mode and at selected design modes using the Floating Pressure - Ganni Cycle. The testing demonstrated that the refrigerator system has a good and fairly constant performance over a wide capacity range and different modes of operation. It also demonstrated the modifications resulted in a LN consumption that met the design for the pure refrigeration mode (which is the most demanding) and was lower than the design for the nominal and maximum capacity modes. In addition, a pulsed-load test, similar to what is expected for cryogenic systems supporting fusion experiments, was conducted to observe the response using the Floating Pressure - Ganni Cycle, which was stable and robust. This paper will discuss the results and analysis of this testing pertaining to the LN consumption, the system efficiency over a wide range of capacity and different modes and the behaviour of the system to a pulsed load.

  12. Design and dynamic behaviour of a cold storage system combined with a solar powered thermoacoustic refrigerator

    International Nuclear Information System (INIS)

    Perier-Muzet, Maxime; Bedecarrats, Jean-Pierre; Stouffs, Pascal; Castaing-Lasvignottes, Jean

    2014-01-01

    A heat powered thermoacoustic refrigerator consists in a thermoacoustic engine that produces acoustic work utilizing heat, coupled to a thermoacoustic cooler that converts this acoustic energy into cooling effect. These machines have already proved their capability in laboratory or in space refrigeration. Previous studies have also demonstrated the possibility of using concentrated solar energy as thermal energy sources for low power heat driven thermoacoustic refrigerators. As other solar refrigeration systems, even if the cooling demand generally increases with the intensity of the solar radiation, one of the major difficulties is to insure a frigorific power supply when there is no, or low, solar radiation. The aim of this work is to study a kW scale solar thermoacoustic refrigerator capable to reach temperatures of the industrial refrigeration domain. This refrigerator is combined with a latent cold storage in order to guarantee a sufficient cooling capacity to face to refrigeration loads in spite of the production fluctuations. A description of the studied prototype is done and the model developed to describe the transient behaviour of the main components of this machine is introduced. The results obtained with a simulation of one week with real solar radiations are presented and the behaviour and the energetic performances of the entire system are analysed. Finally the impact of the sizing of the cold storage system is discussed. With the best storage design, the system is capable to supply a cooling power of 400 W at a temperature equal or lower than −20 °C with an average Coefficient Of Performance of the solar thermoacoustic refrigerator equal to 21%

  13. Commissioning and Operational Experience with 1 kW Class Helium Refrigerator/Liquefier for SST-1

    Science.gov (United States)

    Dhard, C. P.; Sarkar, B.; Misra, Ruchi; Sahu, A. K.; Tanna, V. L.; Tank, J.; Panchal, P.; Patel, J. C.; Phadke, G. D.; Saxena, Y. C.

    2004-06-01

    The helium refrigerator/liquefier (R/L) for the Steady State Super conducting Tokamak (SST-1) has been developed with very stringent specifications for the different operational modes. The total refrigeration capacity is 650 W at 4.5 K and liquefaction capacity of 200 l/h. A cold circulation pump is used for the forced flow cooling of 300 g/s supercritical helium (SHe) for the magnet system (SCMS). The R/L has been designed also to absorb a 200 W transient heat load of the SCMS. The plant consists of a compressor station, oil removal system, on-line purifier, Main Control Dewar (MCD) with associated heat exchangers, cold circulation pump and warm gas management system. An Integrated Flow Control and Distribution System (IFDCS) has been designed, fabricated and installed for distribution of SHe in the toroidal and poloidal field coils as well as liquid helium for cooling of 10 pairs of current leads. A SCADA based control system has been designed using PLC for R/L as well as IFDCS. The R/L has been commissioned and required parameters were achieved confirming to the process. All the test results and commissioning experiences are discussed in this paper.

  14. Grey-box Modeling for System Identification of Household Refrigerators: a Step Toward Smart Appliances

    DEFF Research Database (Denmark)

    Costanzo, Giuseppe Tommaso; Sossan, Fabrizio; Marinelli, Mattia

    2013-01-01

    units, which operation can be shifted within temperature and operational constraints. Even if the refrigerators are not intended to be used as smart loads, validated models are useful in predicting units consumption. This information can increase the optimality of the management of other flexible units......This paper presents the grey-box modeling of a vapor-compression refrigeration system for residential applications based on maximum likelihood estimation of parameters in stochastic differential equations. Models obtained are useful in the view of controlling refrigerators as flexible consumption...

  15. Helium refrigerator-liquefier system for MHD generator

    International Nuclear Information System (INIS)

    Akiyama, Y.; Ishii, H.; Mori, Y.; Yamamoto, M.; Wada, R.; Ando, M.

    1974-01-01

    MHD power generators have been investigated in the Electro-Technical Laboratory as one of the National Research and Development Programmes. A helium refrigerator-liquefier system has been developed to cool the superconducting magnet for a 1000 kW class MHD power generator. The turboexpander with low temperature gas bearings and an alternator had been developed for the MHD project at the Electro-Technical Laboratory previously. The liquefaction capacity is 250 iota/h and the refrigeration power is 2.9 kW at 20 K. The superconducting magnet is 50 tons and the cryostat has a liquid helium volume of 2700 iota. The evaporation rate is 60 to 80 iota/h. It takes, in all 2 to 3 weeks to fill the cryostat with liquid helium. (author)

  16. High-entropy bulk metallic glasses as promising magnetic refrigerants

    International Nuclear Information System (INIS)

    Huo, Juntao; Huo, Lishan; Li, Jiawei; Men, He; Wang, Xinmin; Chang, Chuntao; Wang, Jun-Qiang; Li, Run-Wei; Inoue, Akihisa

    2015-01-01

    In this paper, the Ho 20 Er 20 Co 20 Al 20 RE 20 (RE = Gd, Dy, and Tm) high-entropy bulk metallic glasses (HE-BMGs) with good magnetocaloric properties are fabricated successfully. The HE-BMGs exhibit a second-order magnetic phase transition. The peak of magnetic entropy change (ΔS M pk ) and refrigerant capacity (RC) reaches 15.0 J kg −1 K −1 and 627 J kg −1 at 5 T, respectively, which is larger than most rare earth based BMGs. The heterogeneous nature of glasses also contributes to the large ΔS M pk and RC. In addition, the magnetic ordering temperature, ΔS M pk and RC can be widely tuned by alloying different rare earth elements. These results suggest that the HE-BMGs are promising magnetic refrigerant at low temperatures

  17. CO2 as a refrigerant

    CERN Document Server

    2014-01-01

    A first edition, the IIR guide “CO2 as a Refrigerant” highlights the application of carbon dioxide in supermarkets, industrial freezers, refrigerated transport, and cold stores as well as ice rinks, chillers, air conditioning systems, data centers and heat pumps. This guide is for design and development engineers needing instruction and inspiration as well as non-technical experts seeking background information on a specific topic. Written by Dr A.B. Pearson, a well-known expert in the field who has considerable experience in the use of CO2 as a refrigerant. Main topics: Thermophysical properties of CO2 – Exposure to CO2, safety precautions – CO2 Plant Design – CO2 applications – Future prospects – Standards and regulations – Bibliography.

  18. A compact rotating dilution refrigerator

    Science.gov (United States)

    Fear, M. J.; Walmsley, P. M.; Chorlton, D. A.; Zmeev, D. E.; Gillott, S. J.; Sellers, M. C.; Richardson, P. P.; Agrawal, H.; Batey, G.; Golov, A. I.

    2013-10-01

    We describe the design and performance of a new rotating dilution refrigerator that will primarily be used for investigating the dynamics of quantized vortices in superfluid 4He. All equipment required to operate the refrigerator and perform experimental measurements is mounted on two synchronously driven, but mechanically decoupled, rotating carousels. The design allows for relative simplicity of operation and maintenance and occupies a minimal amount of space in the laboratory. Only two connections between the laboratory and rotating frames are required for the transmission of electrical power and helium gas recovery. Measurements on the stability of rotation show that rotation is smooth to around 10-3 rad s-1 up to angular velocities in excess of 2.5 rad s-1. The behavior of a high-Q mechanical resonator during rapid changes in rotation has also been investigated.

  19. Comparison of a R744 cascade refrigeration system with R404A and R22 conventional systems for supermarkets

    International Nuclear Information System (INIS)

    Silva, Alessandro da; Pedone Bandarra Filho, Enio; Pontes Antunes, Arthur Heleno

    2012-01-01

    The present article focuses on the energy efficiency and climate performance of three different systems used in supermarket applications. The refrigeration systems consist of a cascade cycle (CO 2 /HFC-404A) – provide nominal refrigerating capacity – with carbon dioxide for subcritical operation and HFC-404A in the high stage temperature stage (pump circuit for normal refrigeration and direct expansion for deep-freezing), and also HFC-404A and HCFC-22 with direct expansion systems. The cascade system presented a lower refrigerant charge, 47 kg of both fluids, which represents less than a half of the refrigerant charge of the other systems. An important factor is the total GWP in case of leakage, where the impact in the atmosphere of the cascade system operating with CO 2 was much less than the two direct expansion systems.

  20. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆

    Science.gov (United States)

    Haidari, Leila A.; Brown, Shawn T.; Wedlock, Patrick; Connor, Diana L.; Spiker, Marie; Lee, Bruce Y.

    2017-01-01

    Background Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Methods Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as “electric refrigerators”) at different locations in the supply chain under various circumstances. Results At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Conclusion Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar

  1. Thermal flow regulator of refrigerant

    International Nuclear Information System (INIS)

    Dubinskij, S.I.; Savchenko, A.G.; Suplin, V.Z.

    1988-01-01

    A thermal flow regulator of refrigerant for helium flow-type temperature-controlled cryostats based on controlling the channel hydraulic resistance due to variation of the flow density and viscosity during liquid helium transformation into the gaseous state. Behind the regulator both two-phase flow and a heated gas can be produced. The regulator resolution is (7-15)x10 -4 l/mW of liquid helium

  2. Carrying capacity of Peucang Island for ecotourism management in Ujung Kulon National Park

    Science.gov (United States)

    Wiyono, K. H.; Muntasib, E. K. S. H.; Yulianda, F.

    2018-05-01

    Peucang Island is one of island in Ujung Kulon National Park (UKNP), appointed as priority area and welcome area for tourism. This research aimed to calculate the carrying capacity of Peucang Island for ecotourism development (Study sites of this research are Karang Copong jungle trail and 8 sites of Peucangs beach). This research used observation method (wildlife exploration, measure the lenght of jungle track, and measure 10 parameters of beach), literature study and and interview method to collect data. The data of jungle track analyzed use Cifuentes’s formula. The result showed that Karang Copong jungle trekking had 20,000 visitors/day for Physical Carrying Capacity (PCC), 4 838 visitors/day for Real Carrying Capacity (RCC), and 6 visitors/day for Efective Carrying Capacity (ECC). Observation of biological aspect showed that there were some damages of vegetation along the track, and the changes in animal behavior. The data of beach carrying capacity analyzed use Yulianda’s formula that measured with the suitability map approach. Based on the suitability map, two beaches were classified in suitable category, while six beaches) were classified in highly suitable category for tourism activities. All of the beaches had different number of carrying capacity, specifically there are 70 visitors/day in highly suitable beach and 27 visitors/day in suitable beach. The number of visitor nowadays still not exceed from carrying capacity number of PCC, RCC of jungle trails and carrying capacity of the beach area, but the number has exceeded from the ECC numbers.

  3. Superconducting tunnel-junction refrigerator

    International Nuclear Information System (INIS)

    Melton, R.G.; Paterson, J.L.; Kaplan, S.B.

    1980-01-01

    The dc current through an S 1 -S 2 tunnel junction, with Δ 2 greater than Δ 1 , when biased with eV 1 +Δ 2 , will lower the energy in S 1 . This energy reduction will be shared by the phonons and electrons. This device is shown to be analogous to a thermoelectric refrigerator with an effective Peltier coefficient π* approx. Δ 1 /e. Tunneling calculations yield the cooling power P/sub c/, the electrical power P/sub e/ supplied by the bias supply, and the cooling efficiency eta=P/sub c//P/sub e/. The maximum cooling power is obtained for eV= +- (Δ 2 -Δ 1 ) and t 1 =T 1 /T/sub c/1 approx. 0.9. Estimates are made of the temperature difference T 2 -T 1 achievable in Al-Pb and Sn-Pb junctions with an Al 2 O 3 tunneling barrier. The performance of this device is shown to yield a maximum cooling efficiency eta approx. = Δ 1 /(Δ 2 -Δ 1 ) which can be compared with that available in an ideal Carnot refrigerator of eta=T 1 /(T 2 -T 1 ). The development of a useful tunnel-junction refrigerator requires a tunneling barrier with an effective thermal conductance per unit area several orders of magnitude less than that provided by the A1 2 O 3 barrier in the Al-Pb and Sn-Pb systems

  4. Mountain Plains Learning Experience Guide: Heating, Refrigeration, & Air Conditioning.

    Science.gov (United States)

    Carey, John

    This Heating, Refrigeration, and Air Conditioning course is comprised of eleven individualized units: (1) Refrigeration Tools, Materials, and Refrigerant; (2) Basic Heating and Air Conditioning; (3) Sealed System Repairs; (4) Basic Refrigeration Systems; (5) Compression Systems and Compressors; (6) Refrigeration Controls; (7) Electric Circuit…

  5. A knowledge management and need-capacity matching approach for community-based disaster management and recovery

    NARCIS (Netherlands)

    Palomares, I.; Galway, L.; Haran, M.; Neef, M.; Woods, C.; Wang, H.

    2015-01-01

    Post-crisis response and recovery necessitates the identification and prioritization of the needs and capacities of the affected community in order to provide efficient and wellcoordinated humanitarian assistance. The Community Based Comprehensive Recovery platform aims to facilitate enhanced

  6. Functional Dependence of Thermodynamic and Thermokinetic Parameters of Refrigerants Used in Mine Air Refrigerators. Part 1 - Refrigerant R407C

    Science.gov (United States)

    Nowak, Bernard; Życzkowski, Piotr; Łuczak, Rafał

    2017-03-01

    The authors of this article dealt with the issue of modeling the thermodynamic and thermokinetic properties (parameters) of refrigerants. The knowledge of these parameters is essential to design refrigeration equipment, to perform their energy efficiency analysis, or to compare the efficiency of air refrigerators using different refrigerants. One of the refrigerants used in mine air compression refrigerators is R407C. For this refrigerant, 23 dependencies were developed, determining its thermodynamic and thermokinetic parameters in the states of saturated liquid, dry saturated vapour, superheated vapor, subcooled liquid, and in the two-phase region. The created formulas have been presented in Tables 2, 5, 8, 10 and 12, respectively. It should be noted that the scope of application of these formulas is wider than the range of changes of that refrigerant during the normal operation of mine refrigeration equipment. The article ends with the statistical verification of the developed dependencies. For this purpose, for each model correlation coefficients and coefficients of determination were calculated, as well as absolute and relative deviations between the given values from the program REFPROP 7 (Lemmon et al., 2002) and the calculated ones. The results of these calculations have been contained in Tables 14 and 15.

  7. Optimal thermoeconomic performance of an irreversible regenerative ferromagnetic Ericsson refrigeration cycle

    International Nuclear Information System (INIS)

    Xu, Zhichao; Guo, Juncheng; Lin, Guoxing; Chen, Jincan

    2016-01-01

    On the basis of the Langevin theory of classical statistical mechanics, the magnetization, entropy, and iso-field heat capacity of ferromagnetic materials are analyzed and their mathematical expressions are derived. An irreversible regenerative Ericsson refrigeration cycle by using a ferromagnetic material as the working substance is established, in which finite heat capacity rates of low and high temperature reservoirs, non-perfect regenerative heat of the refrigeration cycle, additional regenerative heat loss, etc. are taken into account. Based on the regenerative refrigeration cycle model, a thermoeconomic function is introduced as one objective function and optimized with respect to the temperatures of the working substance in the two iso-thermal processes. By means of numerical calculation, the effects of the effective factor of the heat exchangers in high/low temperature reservoir sides, efficiency of the regenerator, heat capacity rate of the low temperature reservoir, and applied magnetic field on the optimal thermoeconomic function as well as the corresponding cooling rate and coefficient of performance are revealed. The results obtained in this paper can provide some theoretical guidance for the optimal design of actual regenerative magnetic refrigerator cycle. - Highlights: • Thermodynamic performance of ferromagnetic material is analyzed. • An irreversible regenerative ferromagnetic Ericsson refrigeration cycle is set up. • The thermoeconomic objective function is introduced and optimized. • Impacts of the thermoeconomic and other parameters are discussed.

  8. Participatory monitoring and evaluation to aid investment in natural resource manager capacity at a range of scales.

    Science.gov (United States)

    Brown, Peter R; Jacobs, Brent; Leith, Peat

    2012-12-01

    Natural resource (NR) outcomes at catchment scale rely heavily on the adoption of sustainable practices by private NR managers because they control the bulk of the NR assets. Public funds are invested in capacity building of private landholders to encourage adoption of more sustainable natural resource management (NRM) practices. However, prioritisation of NRM funding programmes has often been top-down with limited understanding of the multiple dimensions of landholder capacity leading to a failure to address the underlying capacity constraints of local communities. We argue that well-designed participatory monitoring and evaluation of landholder capacity can provide a mechanism to codify the tacit knowledge of landholders about the social-ecological systems in which they are embedded. This process enables tacit knowledge to be used by regional NRM bodies and government agencies to guide NRM investment in the Australian state of New South Wales. This paper details the collective actions to remove constraints to improved NRM that were identified by discrete groups of landholders through this process. The actions spanned geographical and temporal scales, and responsibility for them ranged across levels of governance.

  9. 10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.

    Science.gov (United States)

    2010-01-01

    ... functional characteristics that affect energy consumption. Commercial refrigerator, freezer, and refrigerator... formed by the plane of the door, when the equipment is viewed in cross-section; and (2) For equipment...

  10. HeREF-2003: Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 Cost per participant: 500.- CHF Language: Bilingual English...

  11. HeREF-2003 : Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. • Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 • Cost per participant: 500.- CHF ...

  12. Not all counterclockwise thermodynamic cycles are refrigerators

    Science.gov (United States)

    Dickerson, R. H.; Mottmann, J.

    2016-06-01

    Clockwise cycles on PV diagrams always represent heat engines. It is therefore tempting to assume that counterclockwise cycles always represent refrigerators. This common assumption is incorrect: most counterclockwise cycles cannot be refrigerators. This surprising result is explored here for quasi-static ideal gas cycles, and the necessary conditions for refrigeration cycles are clarified. Three logically self-consistent criteria can be used to determine if a counterclockwise cycle is a refrigerator. The most fundamental test compares the counterclockwise cycle with a correctly determined corresponding Carnot cycle. Other criteria we employ include a widely accepted description of the functional behavior of refrigerators, and a corollary to the second law that limits a refrigerator's coefficient of performance.

  13. Magnetocaloric refrigeration near room temperature (invited)

    International Nuclear Information System (INIS)

    Brueck, E.; Tegus, O.; Thanh, D.T.C.; Buschow, K.H.J.

    2007-01-01

    Modern society relies on readily available refrigeration. The ideal cooling machine would be a compact, solid state, silent and energy-efficient heat pump that does not require maintenance. Magnetic refrigeration has three prominent advantages compared to compressor-based refrigeration. First, there are no harmful gases involved, second it may be built more compact as the working material is a solid and third magnetic refrigerators generate much less noise. Recently, a new class of magnetic refrigerant materials for room-temperature applications was discovered. These new materials have important advantages over existing magnetic coolants: They exhibit a large magnetocaloric effect (MCE) in conjunction with a magnetic phase transition of first order. This MCE is, larger than that of Gd metal, which is used in the demonstration refrigerators built to explore the potential of this evolving technology. In the present review, we compare the different materials considering both scientific aspects and industrial applicability

  14. Know-how of refrigerating technology. 2. completely rev. ed. Fachwissen Kaeltetechnik fuer die industrielle und gewerbliche Praxis; Eine Einfuehrung mit Aufgaben und Loesungen

    Energy Technology Data Exchange (ETDEWEB)

    Reisner, K.

    1994-01-01

    This specialized book is based on causes on refrigerating technology held in preparation of apprentices and master candidates for their examinations and on training seminars for operators and users. It bebins with a generalised presentation intended to enable the constructor of a plant to develop an initial concept. The author then explains step by step from the basics of thermodynamics over to fluid mechanics the entire spectrum of subdisciplines that make up refrigerating technology: cooling circuit, compression refrigerants, heat exchange, regulators, piping, required cooling capacity. Practice-oriented calculation models for all fields of refrigerating technology also make the work a valuable reference book. (BWI)

  15. Assessment of propane/commercial butane mixtures as possible alternatives to R134a in domestic refrigerators

    International Nuclear Information System (INIS)

    Fatouh, M.; El Kafafy, M.

    2006-01-01

    The possibility of using hydrocarbon mixtures as working fluids to replace R134a in domestic refrigerators has been evaluated through a simulation analysis in the present work. The performance characteristics of domestic refrigerators were predicted over a wide range of evaporation temperatures (-35 to -10 o C) and condensation temperatures (40-60 deg. C) for various working fluids such as R134a, propane, commercial butane and propane/iso-butane/n-butane mixtures with various propane mass fractions. The performance characteristics of the considered domestic refrigerator were identified by the coefficient of performance (COP), volumetric cooling capacity, cooling capacity, condenser capacity, input power to compressor, discharge temperature, pressure ratio and refrigerant mass flow rate. The results showed that pure propane could not be used as a drop in replacement for R134a in domestic refrigerators because of its high operating pressures and low COP. Commercial butane yields many desirable characteristics but requires a compressor change. The coefficient of performance of the domestic refrigerator using a ternary hydrocarbon mixture with propane mass fractions from 0.5 to 0.7 is higher than that of R134a. Comparison among the considered working fluids confirmed that the average refrigerant mass flow rate of the propoane/commercial butane mixture is 50% lower than that of R134a. Also, the results indicated that R134a and the propoane/commercial butane mixture with 60% propane mass concentration have approximately the same values of saturation pressure, compressor discharge temperature, condenser heat load, input power, cooling capacity and volumetric cooling capacity. However, the pressure ratio of the hydrocarbon mixture with 60% propane is lower than that of R134a by about 11.1%. Finally, the reported results confirmed that the propane/iso-butane/n-butane mixture with 60% propane is the best drop in replacement for R134a in domestic refrigerators under normal

  16. Ecological optimization for generalized irreversible Carnot refrigerators

    International Nuclear Information System (INIS)

    Chen Lingen; Zhu Xiaoqin; Sun Fengrui; Wu Chih

    2005-01-01

    The optimal ecological performance of a Newton's law generalized irreversible Carnot refrigerator with the losses of heat resistance, heat leakage and internal irreversibility is derived by taking an ecological optimization criterion as the objective, which consists of maximizing a function representing the best compromise between the exergy output rate and exergy loss rate (entropy production rate) of the refrigerator. Numerical examples are given to show the effects of heat leakage and internal irreversibility on the optimal performance of generalized irreversible refrigerators

  17. Evaluation of Virtual Refrigerant Mass Flow Sensors

    OpenAIRE

    Kim, Woohyun; Braun, James E.

    2012-01-01

    Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor ma...

  18. Adsorption refrigeration technology theory and application

    CERN Document Server

    Wang, Ruzhu; Wu, Jingyi

    2014-01-01

    Gives readers a detailed understanding of adsorption refrigeration technology, with a focus on practical applications and environmental concerns Systematically covering the technology of adsorption refrigeration, this book provides readers with a technical understanding of the topic as well as detailed information on the state-of-the-art from leading researchers in the field. Introducing readers to background on the development of adsorption refrigeration, the authors also cover the development of adsorbents, various thermodynamic theories, the design of adsorption systems and adsorption refri

  19. The behaviour of a hybrid compressor and ejector refrigeration system with refrigerants 134a and 142b

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, J.I.; Best, R.; Estrada, C.A. [UNAM, Morelos (Mexico). Centro de Investigacion en Energia; Dorantes, R.J. [UAM Azcapotzalco, Reynosa Tamaulipas (Mexico). Dpto. de Energia

    2004-09-01

    A complete theoretical analysis on the thermodynamic behaviour of a HYbrid Compressor and Ejector Refrigeration System - HYCERS - is carried out. An ejector under optimum performance is employed. Two working fluids were selected: refrigerant 142b (HCFC 142b) which has shown very good characteristics in air conditioning applications of ejector systems and refrigerant 134a (HFC134a) which is widely used in refrigeration applications and readily available in most countries. The variation of the generator and condenser temperatures as well as the intercooler pressure were considered for an evaporator temperature of 10{sup o}C and a unitary cooling capacity of 1 kW. The ideal efficiency, the enthalpy-based coefficient of performance, the exergy efficiency and the supplied energy ratio are obtained. With this information, at a moderate condenser and generator temperature of 30 and 85{sup o}C, respectively, the HYCERS working with R134a had the best operation with a highest coefficient of performance of 0.48 and an exergy efficiency of 0.25. On the other hand, if a higher condenser temperature is imposed, the HYCERS with 142b had its best performance at a higher generator temperature. In selecting a working fluid the ejector subsystem behaviour is determinant in system performance. If a working fluid is badly selected, despite having high entrainment ratios, the system will not function properly. Therefore, the methodology here defined becomes an effective tool for selecting adequate working fluids and optimum system design conditions. Also, the employment of a unitary cooling load allows system scaling at any capacity as it increases linearly. (author)

  20. United States: refrigeration industry blows hot

    International Nuclear Information System (INIS)

    Crawford, J.

    1997-01-01

    In the framework of the Kyoto convention on global warming, the american refrigeration industries have undertaken several organizations and contacts with governments and agencies in order to explain the real issues concerning the effects of refrigerant utilization in refrigerating machines on the greenhouse effect, taking into consideration the commercial impact that a ban on certain refrigerants could have on the industry's business. They argue that HFC utilization in this industry is fundamentally non-emissive and that important improvements have been realized concerning tightness and energy consumption

  1. Rotary magnetic refrigerator for superfluid helium production

    International Nuclear Information System (INIS)

    Hakuraku, Y.; Ogata, H.

    1986-01-01

    A new rotary-magnetic refrigerator designed to obtain superfluid helium temperatures by executing a magnetic Carnot cycle is developed. A rotor containing 12 magnetic refrigerants (gadolinium-gallium-garnet) is immersed in liquid helium at 4.2 K and rotated at constant speed in a steady magnetic field distribution. Performance tests demonstrate that the new rotary refrigerator is capable of obtaining a temperature of 1.48 K. The maximum useful cooling power obtained at 1.8 K is 1.81 W which corresponds to a refrigeration efficiency of 34%

  2. A 300 W 18K refrigerator and distribution system for the CERN superconducting RF particle separator

    CERN Document Server

    Steel, A J; Clarke, M E

    1976-01-01

    The refrigerator employs gas lubricated expansion turbines in parallel, and has been designed for a capacity of 300 W at 1.8K and 2 kW below 80K. A low loss system distributes the refrigeration to two cryostats located 90 m apart. The plant may also be used to provide refrigeration or liquefaction at 4.4K. All expansion turbines are interchangeable and one can be switched between two temperature levels, thus giving the plant a capacity of about 150 l hr/sup -1/ when used as a liquefier with liquid nitrogen. Process optimisation has resulted in an extremely compact coldbox. The main features of plant design and control are described. (6 refs).

  3. Comparison between a 1D and a 2D numerical model of an active magnetic regenerative refrigerator

    DEFF Research Database (Denmark)

    Petersen, Thomas Frank; Engelbrecht, Kurt; Bahl, Christian Robert Haffenden

    2008-01-01

    The active magnetic regenerator (AMR) refrigeration system represents an environmentally attractive alternative to vapour-compression refrigeration. This paper compares the results of two numerical AMR models: (1) a 1D finite difference model and (2) a 2D finite element model. Both models simulate...... a reciprocating AMR and can determine the cyclical steady-state temperature profile of the system as well as performance parameters such as the refrigeration capacity, the work input and the coefficient of performance (COP). The models are used to analyse an AMR with a regenerator made of flat parallel plates...... results of overall results such as the refrigeration capacity but that a 2D model is required for a detailed analysis of the phenomena occurring inside the AMR....

  4. Analytical minimization of overall conductance and heat transfer area in refrigeration and heat pump systems and its numerical confirmation

    International Nuclear Information System (INIS)

    Sarkar, J.; Bhattacharyya, Souvik; Ram Gopal, M.

    2007-01-01

    Minimization of heat exchanger area for a specified capacity is very important in the design of refrigeration and heat pump systems, yielding space, weight and cost benefits. In this study, minimization of overall conductance and total area per unit capacity of refrigeration and heat pump systems has been performed analytically. The analysis is performed for constant temperature heat sources and sinks considering both internal and external irreversibilities. Expressions are obtained for optimum hot and cold side refrigerant temperatures, conductance and heat exchanger area ratios. The analytical results have been confirmed by those obtained from a detailed numerical simulation of actual ammonia based refrigeration and heat pump systems, and good agreement is observed. Such theoretical models can be employed as simple yet effective design guidelines for real systems as demonstrated here

  5. Performance analysis of a large-scale helium Brayton cryo-refrigerator with static gas bearing turboexpander

    International Nuclear Information System (INIS)

    Zhang, Yu; Li, Qiang; Wu, Jihao; Li, Qing; Lu, Wenhai; Xiong, Lianyou; Liu, Liqiang; Xu, Xiangdong; Sun, Lijia; Sun, Yu; Xie, Xiujuan; Wang, Bingming; Qiu, Yinan; Zhang, Peng

    2015-01-01

    Highlights: • A 2 kW at 20.0 K helium Brayton cryo-refrigerator is built in China. • A series of tests have been systematically conducted to investigate the performance of the cryo-refrigerator. • Maximum heat conductance proportion (90.7%) appears in the heat exchangers of cold box rather than those of heat reservoirs. • A model of helium Brayton cryo-refrigerator/cycle is presented according to finite-time thermodynamics. - Abstract: Large-scale helium cryo-refrigerator is widely used in superconducting systems, nuclear fusion engineering, and scientific researches, etc., however, its energy efficiency is quite low. First, a 2 kW at 20.0 K helium Brayton cryo-refrigerator is built, and a series of tests have been systematically conducted to investigate the performance of the cryo-refrigerator. It is found that maximum heat conductance proportion (90.7%) appears in the heat exchangers of cold box rather than those of heat reservoirs, which is the main characteristic of the helium Brayton cryo-refrigerator/cycle different from the air Brayton refrigerator/cycle. Other three characteristics also lie in the configuration of refrigerant helium bypass, internal purifier and non-linearity of specific heat of helium. Second, a model of helium Brayton cryo-refrigerator/cycle is presented according to finite-time thermodynamics. The assumption named internal purification temperature depth (PTD) is introduced, and the heat capacity rate of whole cycle is divided into three different regions in accordance with the PTD: room temperature region, upper internal purification temperature region and lower one. Analytical expressions of cooling capacity and COP are obtained, and we found that the expressions are piecewise functions. Further, comparison between the model and the experimental results for cooling capacity of the helium cryo-refrigerator shows that error is less than 7.6%. The PTD not only helps to achieve the analytical formulae and indicates the working

  6. Experimental evaluation of SWCNT-water nanofluid as a secondary fluid in a refrigeration system

    International Nuclear Information System (INIS)

    Vasconcelos, Adriano Akel; Cárdenas Gómez, Abdul Orlando; Bandarra Filho, Enio Pedone; Parise, José Alberto Reis

    2017-01-01

    Highlights: • SWCNT-water nanofluid was used as secondary fluid for a refrigeration system. • For a given HTFS mass flow rate and inlet temperature, nanofluid performed better than base fluid. • Total power consumption was not significantly affected by volume concentration. • Nanoparticle volume fraction ranged from 0 to 0.21%. - Abstract: SWCNT-water (single walled carbon nanotube) nanofluid was tested as a secondary fluid for a 4–9 kW indirect vapor compression refrigeration system. The evaporator, with boiling refrigerant HCFC-22 extracting heat from the nanofluid, was of the brazed plate counter-flow type. A semi-hermetic compressor, an electronic expansion valve (EEV) and an air-cooled condenser were the other main components of the refrigeration cycle. Tests were carried out with the experimental apparatus operating over a range of different volumetric fractions of nanoparticles (0–0.21%) as well as nanofluid inlet temperatures (30–40 °C) and mass flow rates (40–80 g/s). Overall, the performance of the system working with nanofluid as a secondary fluid was superior to that where just the base fluid (i.e., pure water) circulated in the secondary fluid loop, at the same mass flow rate and inlet temperature. The enhanced thermal conductivity of the nanofluid is believed to be the main reason why the refrigeration system with the nanofluid loop, if compared to that with pure water, presented a higher refrigerating capacity.

  7. Alternative test method to assess the energy performance of frost-free refrigerating appliances

    International Nuclear Information System (INIS)

    Hermes, Christian J.L.; Melo, Cláudio; Knabben, Fernando T.

    2013-01-01

    This paper outlines an alternative test method to evaluate the energy consumption of frost-free refrigerators and freezers for residential applications. While the standardized methods require the refrigerating appliance to be kept running according to its onboard control system, which usually drives the refrigerator through an on–off cycling pattern, the proposed approach assesses the refrigerator energy performance in the steady-state regime, being therefore much faster and more reliable. In this procedure, the cooling capacity is matched to the cooling loads by PID-controlled electrical heaters installed within the refrigerated compartments, so that the compartment temperatures are kept at the desired standardized levels. Comparisons between the experimental results obtained using the steady-state energy test and the standardized procedures showed that the former follows closely the trends observed for the latter. - Highlights: ► An alternative test method to assess the energy consumption of refrigerators is proposed. ► PID-controlled electrical heaters were installed within the compartments. ► Steady-state and ISO energy tests were performed and compared. ► Both proposed and standardized test procedures showed similar trends.

  8. Optimization analysis of the motor cooling method in semi-closed single screw refrigeration compressor

    Science.gov (United States)

    Wang, Z. L.; Shen, Y. F.; Wang, Z. B.; Wang, J.

    2017-08-01

    Semi-closed single screw refrigeration compressors (SSRC) are widely used in refrigeration and air conditioning systems owing to the advantages of simple structure, balanced forces on the rotor, high volumetric efficiency and so on. In semi-closed SSRCs, motor is often cooled by suction gas or injected refrigerant liquid. Motor cooling method will changes the suction gas temperature, this to a certain extent, is an important factor influencing the thermal dynamic performance of a compressor. Thus the effects of motor cooling method on the performance of the compressor must be studied. In this paper mathematical models of motor cooling process by using these two methods were established. Influences of motor cooling parameters such as suction gas temperature, suction gas quantity, temperature of the injected refrigerant liquid and quantity of the injected refrigerant liquid on the thermal dynamic performance of the compressor were analyzed. The performances of the compressor using these two kinds of motor cooling methods were compared. The motor cooling capacity of the injected refrigerant liquid is proved to be better than the suction gas. All analysis results obtained can be useful for optimum design of the motor cooling process to improve the efficiency and the energy efficiency of the compressor.

  9. Thermodynamic design of hydrogen liquefaction systems with helium or neon Brayton refrigerator

    Science.gov (United States)

    Chang, Ho-Myung; Ryu, Ki Nam; Baik, Jong Hoon

    2018-04-01

    A thermodynamic study is carried out for the design of hydrogen liquefaction systems with helium (He) or neon (Ne) Brayton refrigerator. This effort is motivated by our immediate goal to develop a small-capacity (100 L/h) liquefier for domestic use in Korea. Eight different cycles are proposed and their thermodynamic performance is investigated in comparison with the existing liquefaction systems. The proposed cycles include the standard and modified versions of He Brayton refrigerators whose lowest temperature is below 20 K. The Brayton refrigerator is in direct thermal contact with the hydrogen flow at atmospheric pressure from ambient-temperature gas to cryogenic liquid. The Linde-Hampson system pre-cooled by a Ne Brayton refrigerator is also considered. Full cycle analysis is performed with the real properties of fluids to estimate the figure of merit (FOM) under an optimized operation condition. It is concluded that He Brayton refrigerators are feasible for this small-scale liquefaction, because a reasonably high efficiency can be achieved with simple and safe (low-pressure) operation. The complete cycles with He Brayton refrigerator are presented for the development of a prototype, including the ortho-to-para conversion.

  10. The Thai-Australian Health Alliance: developing health management capacity and sustainability for primary health care services.

    Science.gov (United States)

    Briggs, D S; Tejativaddhana, P; Cruickshank, M; Fraser, J; Campbell, S

    2010-11-01

    There have been recent calls for a renewed worldwide focus on primary health care. The Thai-Australian Health Alliance addresses this call by developing health care management capability in primary health care professionals in rural Thailand. This paper describes the history and current activities of the Thai-Australian Health Alliance and its approaches to developing health care management capacity for primary care services through international collaborations in research, education and training over a sustained time period. The Alliance's approach is described herein as a distributed network of practices with access to shared knowledge through collaboration. Its research and education approaches involve action research, multi-methods projects, and evaluative studies in the context of workshops and field studies. WHO principles underpin this approach, with countries sharing practical experiences and outcomes, encouraging leadership and management resource networks, creating clearing houses/knowledge centres, and harmonising and aligning partners with their country's health systems. Various evaluations of the Alliance's activities have demonstrated that a capacity building approach that aligns researchers, educators and health practitioners in comparative and reflective activities can be effective in transferring knowledge and skills among a collaboration's partners. Project participants, including primary health care practitioners, health policy makers and academics embraced the need to acquire management skills to sustain primary care units. Participants believe that the approaches described herein were crucial to developing the management skills needed of health care professionals for rural and remote primary health care. The implementation of this initiative was challenged by pre-existing low opinions of the importance of the management role in health care, but with time the Alliance's activities highlighted for all the importance of health care management

  11. Integrating inventory control and capacity management at a maintenance service provider

    NARCIS (Netherlands)

    Buyukkaramikli, N.C.; Ooijen, van H.P.G.; Bertrand, J.W.M.

    2015-01-01

    In this paper, we study the capacity flexibility problem of a maintenance service provider, who is running a repair shop and is responsible for the availability of numerous specialized systems which contain a critical component that is prone to failure. Upon a critical component failure, the

  12. Potential role of phosphate buffering capacity of soils in fertilizer management strategies fitted to environmental goals

    NARCIS (Netherlands)

    Ehlert, P.A.I.; Morel, C.; Fotyma, M.; Destain, J.P.

    2003-01-01

    Sorption behavior and buffering of phosphorus (P) are important, both from an agricultural and an environmental point of view. The objectives of this study were to investigate: (1) the kinetics of the transfer of P from soil to soil solution and assessing P buffering capacity of soils (PBC), as a

  13. Models for QoS-Aware Capacity Management in Cable Access Networks

    NARCIS (Netherlands)

    Attema, T.; van den Berg, Hans Leo; Kempker, P.C.; Worm, D.; van der Vliet-Hameeteman, C.

    In this article, mathematical models are presented that “map‿ measured or predicted network utilisations to user throughputs for given network configurations (segment capacity, subscription speeds etc.). They provide valuable insights into the user experience in cable access networks. The models,

  14. Developing management capacity building package to district health manager in northwest of Iran: A sequential mixed method study.

    Science.gov (United States)

    Tabrizi, Jafar Sadegh; Gholipour, Kamal; Farahbakhsh, Mostafa; Jahanbin, Hasan; Karamuz, Majid

    2016-11-01

    To assess districts health managers educational needs and develop management training programmes. This mixed-method study was carried out between August 2014 and August 2015 in Tabriz, Iran. Four focus group discussion sessions and three semi-structured face-to-face interviews were conducted among district health managers and experts of a health centre. Besides, 52 questionnaires were completed to weigh and finalise management education module and courses. Interviews and focus group discussions were tape-recorded, transcribed and analysed using content analysis method. Data was analysed using SPSS17. There were 52 participants, of whom 40(78.8%) were men and 12(21.2%) were women. All of the subjects (100%) took part in the quantitative phase, while 25(48.08%) participated in the qualitative phase. In the qualitative section, 11(44%) participants were heads of unit/departments in provincial health centre and 14(56%) were district health managers. In the quantitative phase, 30(57.7%) participants were district health managers and 8(28.8%) were heads of units/departments. Moreover, 33(63.4%) participants had medical education. The job experience of 3(5.8%) participants in the current position was below five years. Districts health management training programme consisted of 10modules with 53 educational topics. The normalised score out of a total of 100 for rules and ethics was 75.51, health information management 71.19, management and leadership 69.27, district management 68.08, human resources and organisational creativity 67.58,quality improvement 66.6, health resources management 62.37, planning and evaluation 61.87, research in health system 59.15, and community participation was 53.15. Considering district health managers' qualification in health and medicine, they had not been trained in basic management. Almost all the management and leadership courses were prioritised as most necessary.

  15. Prediction of Dangerous Time in Case Hydrocarbon Refrigerant Leaks into Household Refrigerator Cabinet

    Science.gov (United States)

    Meguro, Takatoshi; Kaji, Nobufuji; Miyake, Kunihiro

    Hydrocarbon refrigerators are now on sale in European countries. However, hydrocarbons are flammable. A common claim is that concentration of hydrocarbon in the refrigerator could exceed the lower explosive limit by a sudden leak and then a spark ignites a flame causing overpressure. There is the need of the studies on potential risks originated from the use of flammable refrigerants. Thus, the flow rate of the fresh air into the refrigerator cabinet has been defined experimentally, and the spatial average concentration in the refrigerator cabinet has been analyzed theoretically to predict the dangerous time in excess of the lower explosive limit.

  16. Consolidating a Distributed Compound Management Capability into a Single Installation: The Application of Overall Equipment Effectiveness to Determine Capacity Utilization.

    Science.gov (United States)

    Green, Clive; Taylor, Daniel

    2016-12-01

    Compound management (CM) is a critical discipline enabling hit discovery through the production of assay-ready compound plates for screening. CM in pharma requires significant investments in manpower, capital equipment, repairs and maintenance, and information technology. These investments are at risk from external factors, for example, new technology rendering existing equipment obsolete and strategic site closures. At AstraZeneca, we faced the challenge of evaluating the number of CM sites required to support hit discovery in response to site closures and pressure on our operating budget. We reasoned that overall equipment effectiveness, a tool used extensively in the manufacturing sector, could determine the equipment capacity and appropriate number of sites. We identified automation downtime as the critical component governing capacity, and a connection between automation downtime and the availability of skilled staff. We demonstrated that sufficient production capacity existed in two sites to meet hit discovery demand without the requirement for an additional investment of $7 million in new facilities. In addition, we developed an automated capacity model that incorporated an extended working-day pattern as a solution for reducing automation downtime. The application of this solution enabled the transition to a single site, with an annual cost saving of $2.1 million. © 2015 Society for Laboratory Automation and Screening.

  17. Enhancement of refrigerated storage of fishery products using gamma irradiation

    International Nuclear Information System (INIS)

    Lewis, N.F.; Ghadi, S.V.; Doke, S.N.; Venugopal, V.; Alur, M.D.

    1977-01-01

    A processe combining gamma radiation treatment with refrigeration has been suggested for better utilization of sea-foods of which large quantities will be available for processing after the implementation of the expansion programme of the fishing industry in India and the present capacity of refrigeration industry may be found to be inadequate to meet the demands of the expanded fishing industry. Gamma irradiation in the range of 0.1-0.25 Mrad enhances 2-3 fold storage life of refrigerated sea-foods. Low dose radiation treatment inactivates the gram-negative bacteria, the main source of sea-food spoilage, but not C. botulinum the growth of which is inhibited by the gram-negative bacteria in unirradiated sea-foods. Care has, therefore, to be taken to use a radiation dose which does not totally eliminate these bacteria so that a small percentage which survives leads to terminal spoilage and rejection of sea-foods even before C. botulinum produces toxins thus avoiding food poisoning. (M.G.B.)

  18. TRANSPORT PROPERTIES FOR REFRIGERANT MIXTURES

    Directory of Open Access Journals (Sweden)

    V. Geller

    2014-06-01

    Full Text Available A set of models to predict viscosity and thermal conductivity of refrigerant mixtures is developed. A general model for viscosity and thermal conductivity use the three contributions sum form (the dilute-gas terms, the residual terms, and the liquid terms. The corresponding states model is recommended to predict the dense gas transport properties over a range of reduced density from 0 to 2. It is shown that the RHS model provides the most reliable results for the saturated-liquid and the compressed-liquid transport properties over a range of given temperatures from 0,5 to 0,95.

  19. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  20. Refrigeration and air-conditioning

    CERN Document Server

    Hundy, G H; Welch, T C

    2008-01-01

    Now in its fourth edition, this respected text delivers a comprehensive introduction to the principles and practice of refrigeration. Clear and straightforward, it is designed for students (NVQ/vocational level) and professional HVAC engineers, including those on short or CPD courses. Inexperienced readers are provided with a comprehensive introduction to the fundamentals of the technology. With its concise style yet broad sweep the book covers most of the applications professionals will encounter, enabling them to understand, specify, commission, use and maintain these systems. Many readers w

  1. A miniaturized plastic dilution refrigerator

    International Nuclear Information System (INIS)

    Bindilatti, V.; Oliveira, N.F.Jr.; Martin, R.V.; Frossati, G.

    1996-01-01

    We have built and tested a miniaturized dilution refrigerator, completely contained (still, heat exchanger and mixing chamber) inside a plastic (PVC) tube of 10 mm diameter and 170 mm length. With a 25 cm 2 CuNi heat exchanger, it reached temperatures below 50 mK, for circulation rates below 70 μmol/s. The cooling power at 100 mK and 63 μmol/s was 45 μW. The experimental space could accommodate samples up to 6 mm in diameter. (author)

  2. Experimental and Numerical Study of Effect of Thermal Management on Storage Capacity of the Adsorbed Natural Gas Vessel

    KAUST Repository

    Ybyraiymkul, Doskhan

    2017-07-08

    One of the main challenges in the adsorbed natural gas (ANG) storage system is the thermal effect of adsorption, which significantly lowers storage capacity. These challenges can be solved by efficient thermal management system. In this paper, influence of thermal management on storage capacity of the ANG vessel was studied experimentally and numerically. 3D numerical model was considered in order to understand heat transfer phenomena and analyze influence of thermal control comprehensively. In addition, a detailed 2D axisymmetric unit cell model of adsorbent layer with heat exchanger was developed, followed by optimization of heat exchanging device design to minimize volume occupied by fins and tubes. Heat transfer, mass transfer and adsorption kinetics, which occur in ANG vessel during charging process, are accounted for in models. Nelder-Mead method is implemented to obtain the geometrical parameters, which lead to the optimal characteristics of heat exchange. A new optimized configuration of ANG vessel was developed with compact heat exchanger. Results show that storage capacity of the ANG vessel increased significantly due to lowering of heat exchanger volume for 3 times from 13.5% to 4.3% and effective temperature control.

  3. Calculation of intercepted runoff depth based on stormwater quality and environmental capacity of receiving waters for initial stormwater pollution management.

    Science.gov (United States)

    Peng, Hai-Qin; Liu, Yan; Gao, Xue-Long; Wang, Hong-Wu; Chen, Yi; Cai, Hui-Yi

    2017-11-01

    While point source pollutions have gradually been controlled in recent years, the non-point source pollution problem has become increasingly prominent. The receiving waters are frequently polluted by the initial stormwater from the separate stormwater system and the wastewater from sewage pipes through stormwater pipes. Consequently, calculating the intercepted runoff depth has become a problem that must be resolved immediately for initial stormwater pollution management. The accurate calculation of intercepted runoff depth provides a solid foundation for selecting the appropriate size of intercepting facilities in drainage and interception projects. This study establishes a separate stormwater system for the Yishan Building watershed of Fuzhou City using the InfoWorks Integrated Catchment Management (InfoWorks ICM), which can predict the stormwater flow velocity and the flow of discharge outlet after each rainfall. The intercepted runoff depth is calculated from the stormwater quality and environmental capacity of the receiving waters. The average intercepted runoff depth from six rainfall events is calculated as 4.1 mm based on stormwater quality. The average intercepted runoff depth from six rainfall events is calculated as 4.4 mm based on the environmental capacity of the receiving waters. The intercepted runoff depth differs when calculated from various aspects. The selection of the intercepted runoff depth depends on the goal of water quality control, the self-purification capacity of the water bodies, and other factors of the region.

  4. Public Sector Reform and Governance for Adaptation: Implications of New Public Management for Adaptive Capacity in Mexico and Norway

    Science.gov (United States)

    Eakin, Hallie; Eriksen, Siri; Eikeland, Per-Ove; Øyen, Cecilie

    2011-03-01

    Although many governments are assuming the responsibility of initiating adaptation policy in relation to climate change, the compatibility of "governance-for-adaptation" with the current paradigms of public administration has generally been overlooked. Over the last several decades, countries around the globe have embraced variants of the philosophy of administration broadly called "New Public Management" (NPM) in an effort to improve administrative efficiencies and the provision of public services. Using evidence from a case study of reforms in the building sector in Norway, and a case study of water and flood risk management in central Mexico, we analyze the implications of the adoption of the tenets of NPM for adaptive capacity. Our cases illustrate that some of the key attributes associated with governance for adaptation—namely, technical and financial capacities; institutional memory, learning and knowledge; and participation and accountability—have been eroded by NPM reforms. Despite improvements in specific operational tasks of the public sector in each case, we show that the success of NPM reforms presumes the existence of core elements of governance that have often been found lacking, including solid institutional frameworks and accountability. Our analysis illustrates the importance of considering both longer-term adaptive capacities and short-term efficiency goals in public sector administration reform.

  5. Assessment of management capacity to improve the value of health-care systems: a survey

    OpenAIRE

    Rebecca L Weintraub, MD; Keri Wachter, BA; Jennifer Goldsmith, MS; Marie J Teichman, BA; Eda Algur; Julie D Rosenberg, MPH

    2017-01-01

    Background: Strong management is important for high-value health-care systems if returns on global health investments are to be delivered and the Sustainable Development Goals met by 2030. Managers are responsible for care delivery systems and strategies, making sure that health services benefit the population they intend to serve. Most managers in resource-limited settings work at the district level and below, with little training in non-clinical skills. They are often health care providers ...

  6. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  7. Thermodynamic performance of R502 alternative refrigerant mixtures for low temperature and transport applications

    International Nuclear Information System (INIS)

    Park, Ki-Jung; Jung, Dongsoo

    2007-01-01

    In this study, two pure hydrocarbon refrigerants, R1270 (propylene) and R290 (propane), and three binary mixtures composed of R1270, R290 and R152a were tested in a refrigerating bench tester with a scroll compressor in an attempt to substitute R502, which is used in most low temperature and transport refrigeration applications. The test bench provided 3-3.5 kW capacity, and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions, resulting in the average saturation temperatures of -28 and 45 o C in the evaporator and condenser, respectively. The test results showed that all refrigerants tested had 9.6-18.7% higher capacity and 17.1-27.3% higher COP than R502. The compressor discharge temperature of R1270 was similar to that of R502, while those of all the other refrigerants were 23.7-27.9 o C lower than that of R502. For all alternative refrigerants, the charge was reduced up to 60% as compared to R502. There, of course, was no problem with mineral oil, since the mixtures were mainly composed of hydrocarbons. Since some of them are mixtures, one can change their compositions a little to suit various needs in many applications without significant deterioration of the performance. Overall, these alternative refrigerants offer better system performance and reliability than R502 and can be used as long term substitutes for R502 due to their excellent environmental properties

  8. Energy and exergy analyses of a bi-evaporator compression/ejection refrigeration cycle

    International Nuclear Information System (INIS)

    Geng, Lihong; Liu, Huadong; Wei, Xinli; Hou, Zhonglan; Wang, Zhenzhen

    2016-01-01

    Highlights: • A bi-evaporator compression/ejection refrigeration cycle was studied experimentally. • Experiments were operated at the same external conditions and cooling capacities. • COP improvement was 16.94–30.59% higher than that of the conventional system. • The exergy efficiency of the R134a cycle was improved by 7.57–28.29%. - Abstract: Aiming to reduce the throttling loss in the vapor compression refrigeration cycle, a bi-evaporator compression/ejection refrigeration cycle (BCERC) using an ejector as the expansion device was experimentally investigated with R134a refrigerant. The effects of the compressor frequency and the operating conditions on the coefficient of performance (COP) and the amount of exergy destruction of each component were studied. The results were compared with that of the conventional vapor compression refrigeration cycle under the same external operating conditions and cooling capacities. Results showed that the refrigeration cycle with an ejector as the expansion device exhibited lower irreversibility for each component and total system in comparison with the conventional vapor compression refrigeration cycle. The COP and the exergy efficiency of the BCERC were higher than that of the conventional system. The COP and exergy efficiency improvements became more significant as the condenser water temperature increased, the evaporator water temperature decreased and the compressor frequency increased. In the BCERC with a constant frequency compressor, the COP and the exergy efficiency could be improved by 16.94–30.59%, 7.57–28.29%, respectively. The COP and the exergy efficiency of the BCERC with a variable frequency compressor could increase by around 32.64% and 23.32%, respectively.

  9. Overall conductance and heat transfer area minimization of refrigerators and heat pumps with finite heat reservoirs

    International Nuclear Information System (INIS)

    Sarkar, J.; Bhattacharyya, Souvik

    2007-01-01

    In the present study, the overall conductance and the overall heat transfer area per unit capacity of refrigeration and heat pump systems have been minimized analytically considering both internal and external irreversibilities with variable temperature (finite capacity) heat reservoirs. Hot and cold side refrigerant temperatures, conductance and heat transfer area ratios have been optimized to attain this goal. The results have been verified with the more elaborate numerical optimization results obtained for ammonia based vapour compression refrigeration and heat pump systems working with variable temperature reservoirs. It is observed that the analytical results for optimum refrigerant temperatures, minimum overall conductance and heat transfer area deviate marginally from the numerically optimized results (within 1%), if one assumes a constant heat rejection temperature. The deviation of minimum overall conductance and heat transfer area is more (about 20%), if one considers both the desuperheating and condensation regions separately. However, in the absence of complex and elaborate numerical models, the simple analytical results obtained here can be used as reasonably accurate preliminary guidelines for optimization of refrigeration and heat pump systems

  10. Understanding enabling capacities for managing the 'wicked problem' of nonpoint source water pollution in catchments: a conceptual framework.

    Science.gov (United States)

    Patterson, James J; Smith, Carl; Bellamy, Jennifer

    2013-10-15

    Nonpoint source (NPS) water pollution in catchments is a 'wicked' problem that threatens water quality, water security, ecosystem health and biodiversity, and thus the provision of ecosystem services that support human livelihoods and wellbeing from local to global scales. However, it is a difficult problem to manage because water catchments are linked human and natural systems that are complex, dynamic, multi-actor, and multi-scalar in nature. This in turn raises questions about understanding and influencing change across multiple levels of planning, decision-making and action. A key challenge in practice is enabling implementation of local management action, which can be influenced by a range of factors across multiple levels. This paper reviews and synthesises important 'enabling' capacities that can influence implementation of local management action, and develops a conceptual framework for understanding and analysing these in practice. Important enabling capacities identified include: history and contingency; institutional arrangements; collaboration; engagement; vision and strategy; knowledge building and brokerage; resourcing; entrepreneurship and leadership; and reflection and adaptation. Furthermore, local action is embedded within multi-scalar contexts and therefore, is highly contextual. The findings highlight the need for: (1) a systemic and integrative perspective for understanding and influencing change for managing the wicked problem of NPS water pollution; and (2) 'enabling' social and institutional arenas that support emergent and adaptive management structures, processes and innovations for addressing NPS water pollution in practice. These findings also have wider relevance to other 'wicked' natural resource management issues facing similar implementation challenges. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. 46 CFR 147.90 - Refrigerants.

    Science.gov (United States)

    2010-10-01

    .../ASHRAE 34-78 may be carried as ships' stores. (b) Refrigerants contained in a vessel's operating system... 46 Shipping 5 2010-10-01 2010-10-01 false Refrigerants. 147.90 Section 147.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other...

  12. 46 CFR 154.1720 - Indirect refrigeration.

    Science.gov (United States)

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Special Design and Operating Requirements § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene...

  13. Refrigeration: Introducing energy saving opportunities for business

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-04-15

    In some industries, most notably food and drink and chemicals, refrigeration accounts for a significant proportion of overall site energy costs. For instance, in the industrial handling of meat, poultry and fish, it often accounts for 50% of total energy costs. In ice-cream production the proportion is 70%. In a number of commercial sectors, refrigeration also represents a significant proportion of overall energy costs. For example: Cold storage 90%; Food supermarkets 50%; Small shops with refrigerated cabinets 70% or over; Pubs and clubs 30%. Against these high costs, even a small reduction in refrigeration energy use can offer significant cost savings, resulting in increased profits. Energy saving need not be expensive. Energy savings of up to 20% can be realised in many refrigeration plant through actions that require little or no investment. In addition, improving the efficiency and reducing the load on a refrigeration plant can improve reliability and reduce the likelihood of a breakdown. Most organisations can save energy and money on refrigeration by: More efficient equipment; Good maintenance; Housekeeping and control. This publication provides an understanding of the operation of refrigeration systems, identifies where savings can be realised and will enable readers to present an informed case on energy savings to key decision makers within their organisation. (GB)

  14. Investigation of adsorption performance deterioration in silica gel–water adsorption refrigeration

    International Nuclear Information System (INIS)

    Wang Dechang; Zhang Jipeng; Xia Yanzhi; Han Yanpei; Wang Shuwei

    2012-01-01

    Highlights: ► Adsorption deterioration of silica gel in refrigeration systems is verified. ► Possible factors to cause such deterioration are analyzed. ► Specific surface area, silanol content and adsorption capacity are tested. ► The pollution is the primary factor to decline the adsorption capacity. ► Deteriorated samples are partly restored after being processed by acid solution. - Abstract: Silica gel acts as a key role in adsorption refrigeration systems. The adsorption deterioration must greatly impact the performance of the silica gel–water adsorption refrigeration system. In order to investigate the adsorption deterioration of silica gel, many different silica gel samples were prepared according to the application surroundings of silica gel in adsorption refrigeration systems after the likely factors to cause such deterioration were analyzed. The specific surface area, silanol content, adsorption capacity and pore size distribution of those samples were tested and the corresponding adsorption isotherms were achieved. In terms of the experimental data comparisons, it could be found that there are many factors to affect the adsorption performance of silica gel, but the pollution was the primary one to decline the adsorption capacity. In addition, the adsorption performance of the deteriorated samples after being processed by acid solution was explored in order to find the possible methods to restore its adsorption performance.

  15. Management of Surface Drying Temperature to Increase Antioxidant Capacity of Thyme Leaf Extracts (Thymus vulgaris L.)

    OpenAIRE

    RODRIGUEZ CORTINA, JADER; Melo, E.C.; Mulet Pons, Antonio; Bon Corbín, José

    2014-01-01

    [EN] Thyme leaves are an important source of essential oils with antioxidant activity; these compounds are located in trichomes on the leaf surface. The drying conditions affect not only the drying time but also the antioxidant activity. In the literature, a drying temperature of 70 ºC appears to be the best for drying thyme leaves according to their antioxidant capacity. Considering drying periods at different temperature also could be quality beneficial. From these considerations, the goal ...

  16. Studies on capacity management for factories of nuclear fuel for research reactors

    Energy Technology Data Exchange (ETDEWEB)

    Negro, Miguel Luiz Miotto; Durazzo, Michelangelo; Mesquita, Marco Aurélio de; Carvalho, Elita Fontenele Urano de; Andrade, Delvonei Alves de, E-mail: mlnegro@ipen.br, E-mail: mdurazzo@ipen.br, E-mail: elitaucf@ipen.br, E-mail: delvonei@ipen.br, E-mail: mamesqui@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Universidade de São Paulo (USP), SP (Brazil). Escola Politécnica. Departamento de Engenharia de Produção

    2017-11-01

    The use and the power of nuclear reactors for research and materials testing is increasing worldwide. That implies the demand for nuclear fuel for this kind of reactors is rising. Thus, the production facilities of this kind of fuel need reliable guidance on how to augment their production in order to meet the increasing demand efficiently, safely and keeping good quality. Focus is given to factories that produce plate type fuel elements loaded with LEU U{sub 3}Si{sub 2}-Al fuel, which are typically used in nuclear research reactors. Of the various production routes for this kind of fuel, we chose the route which uses hydrolysis of uranium hexafluoride. Raising the capacity of this kind of plants faces several problems, especially regarding safety against nuclear criticality. Some of these problems are briefly addressed. The new issue of the paper is the application of knowledge from the area of production administration to the fabrication of nuclear fuel for research reactors. A specific method for the increase in production capacity is proposed. That method was tested by means of discrete event simulation. The data were collected from the nuclear fuel factory at IPEN. The results indicated the proposed method achieved its goal as well as ways of raising production capacity in up to 50%. (author). (author)

  17. Studies on capacity management for factories of nuclear fuel for research reactors

    International Nuclear Information System (INIS)

    Negro, Miguel Luiz Miotto; Durazzo, Michelangelo; Mesquita, Marco Aurélio de; Carvalho, Elita Fontenele Urano de; Andrade, Delvonei Alves de; Universidade de São Paulo

    2017-01-01

    The use and the power of nuclear reactors for research and materials testing is increasing worldwide. That implies the demand for nuclear fuel for this kind of reactors is rising. Thus, the production facilities of this kind of fuel need reliable guidance on how to augment their production in order to meet the increasing demand efficiently, safely and keeping good quality. Focus is given to factories that produce plate type fuel elements loaded with LEU U_3Si_2-Al fuel, which are typically used in nuclear research reactors. Of the various production routes for this kind of fuel, we chose the route which uses hydrolysis of uranium hexafluoride. Raising the capacity of this kind of plants faces several problems, especially regarding safety against nuclear criticality. Some of these problems are briefly addressed. The new issue of the paper is the application of knowledge from the area of production administration to the fabrication of nuclear fuel for research reactors. A specific method for the increase in production capacity is proposed. That method was tested by means of discrete event simulation. The data were collected from the nuclear fuel factory at IPEN. The results indicated the proposed method achieved its goal as well as ways of raising production capacity in up to 50%. (author). (author)

  18. Magnetic Refrigeration Technology for High Efficiency Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Boeder, A; Zimm, C

    2006-09-30

    Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate

  19. Sorption compressor/mechanical expander hybrid refrigeration

    Science.gov (United States)

    Jones, J. A.; Britcliffe, M.

    1987-01-01

    Experience with Deep Space Network (DSN) ground-based cryogenic refrigerators has proved the reliability of the basic two-stage Gifford-McMahon helium refrigerator. A very long life cryogenic refrigeration system appears possible by combining this expansion system or a turbo expansion system with a hydride sorption compressor in place of the usual motor driven piston compressor. To test the feasibility of this system, a commercial Gifford-McMahon refrigerator was tested using hydrogen gas as the working fluid. Although no attempt was made to optimize the system for hydrogen operation, the refrigerator developed 1.3 W at 30 K and 6.6 W at 60 K. The results of the test and of theoretical performances of the hybrid compressor coupled to these expansion systems are presented.

  20. Compatibility of refrigerants and lubricants with elastomers

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.

    1993-01-01

    The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

  1. Operating Manual of Helium Refrigerator (Rev. 2)

    Energy Technology Data Exchange (ETDEWEB)

    Song, K.M.; Son, S.H.; Kim, K.S.; Lee, S.K.; Kim, M.S. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    A helium refrigerator was installed as a supplier of 20K cold helium to the cryogenic distillation system of WTRF pilot plant. The operating procedures of the helium refrigerator, helium compressor and auxiliary apparatus are described for the safety and efficient operation in this manual. The function of the helium refrigerator is to remove the impurities from the compressed helium of about 250psig, to cool down the helium from ambient temperature to 20K through the heat exchanger and expansion engine and to transfer the cold helium to the cryogenic distillation system. For the smoothly operation of helium refrigerator, the preparation, the start-up, the cool-down and the shut-down of the helium refrigerator are described in this operating manual. (author). 3 refs., 14 tabs.

  2. Novel materials for laser refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Hehlen, Markus P [Los Alamos National Laboratory

    2009-01-01

    The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which {Dirac_h}{omega}{sub max} < E{sub p}/8, where {Dirac_h}{omega}{sub max} is the maximum phonon energy of the host material and E{sub p} is the pump energy of the rare-earth dopant. Transition-metal and OH{sup -}impurities at levels >100 ppb are believed to be the main factors for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF{sub 3}-LiF are considered as alternatives to ZBLAN. The crystalline system KPb{sub 2}CI{sub 5} :Dy{sup 3+} is identified as a prime candidate for high-efficiency laser cooling.

  3. Constraints to Senior Management's Capacity to Implement the Performance Management System in Senior Secondary Schools in Botswana

    Science.gov (United States)

    Bulawa, Philip

    2013-01-01

    The performance management system in different forms has been in existence in many countries for some years. In 1999 Botswana like other countries decided to implement a performance management system (PMS) across the entire public service including schools. At its introduction, the government explained the purpose for which this reform was being…

  4. Review of investigations in eco-friendly thermoacoustic refrigeration system

    Directory of Open Access Journals (Sweden)

    Raut Ashish S.

    2017-01-01

    Full Text Available To reduce greenhouse gas emissions, internationally research and development is intended to improve the performance of conventional refrigeration system also growth of new-fangled refrigeration technology of potentially much lesser ecological impact. This paper gives brief review of research and development in thermoacoustic refrigeration also the existing situation of thermoacoustic refrigeration system. Thermoacoustic refrigerator is a novel sort of energy conversion equipment which converts acoustic power into heat energy by thermoacoustic effect. Thermoacoustic refrigeration is an emergent refrigeration technology in which there are no moving elements or any environmentally injurious refrigerants during its working. The concept of thermoacoustic refrigeration system is explained, the growth of thermoacoustic refrigeration, various investigations into thermoacoustic refrigeration system, various optimization techniques to improve coefficient of performance, different stacks and resonator tube designs to improve heat transfer rate, various gases, and other parameters like sound generation have been reviewed.

  5. Simulation of Water Environmental Capacity and Pollution Load Reduction Using QUAL2K for Water Environmental Management

    Science.gov (United States)

    Zhang, Ruibin; Qian, Xin; Yuan, Xingcheng; Ye, Rui; Xia, Bisheng; Wang, Yulei

    2012-01-01

    In recent years, water quality degradation associated with rapid socio-economic development in the Taihu Lake Basin, China, has attracted increasing attention from both the public and the Chinese government. The primary sources of pollution in Taihu Lake are its inflow rivers and their tributaries. Effective water environmental management strategies need to be implemented in these rivers to improve the water quality of Taihu Lake, and to ensure sustainable development in the region. The aim of this study was to provide a basis for water environmental management decision-making. In this study, the QUAL2K model for river and stream water quality was applied to predict the water quality and environmental capacity of the Hongqi River, which is a polluted tributary in the Taihu Lake Basin. The model parameters were calibrated by trial and error until the simulated results agreed well with the observed data. The calibrated QUAL2K model was used to calculate the water environmental capacity of the Hongqi River, and the water environmental capacities of CODCr NH3-N, TN, and TP were 17.51 t, 1.52 t, 2.74 t and 0.37 t, respectively. The results showed that the NH3-N, TN, and TP pollution loads of the studied river need to be reduced by 50.96%, 44.11%, and 22.92%, respectively to satisfy the water quality objectives. Thus, additional water pollution control measures are needed to control and reduce the pollution loads in the Hongqi River watershed. The method applied in this study should provide a basis for water environmental management decision-making. PMID:23222206

  6. Simulation of water environmental capacity and pollution load reduction using QUAL2K for water environmental management.

    Science.gov (United States)

    Zhang, Ruibin; Qian, Xin; Yuan, Xingcheng; Ye, Rui; Xia, Bisheng; Wang, Yulei

    2012-12-07

    In recent years, water quality degradation associated with rapid socio-economic development in the Taihu Lake Basin, China, has attracted increasing attention from both the public and the Chinese government. The primary sources of pollution in Taihu Lake are its inflow rivers and their tributaries. Effective water environmental management strategies need to be implemented in these rivers to improve the water quality of Taihu Lake, and to ensure sustainable development in the region. The aim of this study was to provide a basis for water environmental management decision-making. In this study, the QUAL2K model for river and stream water quality was applied to predict the water quality and environmental capacity of the Hongqi River, which is a polluted tributary in the Taihu Lake Basin. The model parameters were calibrated by trial and error until the simulated results agreed well with the observed data. The calibrated QUAL2K model was used to calculate the water environmental capacity of the Hongqi River, and the water environmental capacities of COD(Cr) NH(3)-N, TN, and TP were 17.51 t, 1.52 t, 2.74 t and 0.37 t, respectively. The results showed that the NH(3)-N, TN, and TP pollution loads of the studied river need to be reduced by 50.96%, 44.11%, and 22.92%, respectively to satisfy the water quality objectives. Thus, additional water pollution control measures are needed to control and reduce the pollution loads in the Hongqi River watershed. The method applied in this study should provide a basis for water environmental management decision-making.

  7. Simulation of Water Environmental Capacity and Pollution Load Reduction Using QUAL2K for Water Environmental Management

    Directory of Open Access Journals (Sweden)

    Yulei Wang

    2012-12-01

    Full Text Available In recent years, water quality degradation associated with rapid socio-economic development in the Taihu Lake Basin, China, has attracted increasing attention from both the public and the Chinese government. The primary sources of pollution in Taihu Lake are its inflow rivers and their tributaries. Effective water environmental management strategies need to be implemented in these rivers to improve the water quality of Taihu Lake, and to ensure sustainable development in the region. The aim of this study was to provide a basis for water environmental management decision-making. In this study, the QUAL2K model for river and stream water quality was applied to predict the water quality and environmental capacity of the Hongqi River, which is a polluted tributary in the Taihu Lake Basin. The model parameters were calibrated by trial and error until the simulated results agreed well with the observed data. The calibrated QUAL2K model was used to calculate the water environmental capacity of the Hongqi River, and the water environmental capacities of CODCr NH3-N, TN, and TP were 17.51 t, 1.52 t, 2.74 t and 0.37 t, respectively. The results showed that the NH3-N, TN, and TP pollution loads of the studied river need to be reduced by 50.96%, 44.11%, and 22.92%, respectively to satisfy the water quality objectives. Thus, additional water pollution control measures are needed to control and reduce the pollution loads in the Hongqi River watershed. The method applied in this study should provide a basis for water environmental management decision-making.

  8. A Multi-Tiered Approach for Building Capacity in Hydrologic Modeling for Water Resource Management in Developing Regions

    Science.gov (United States)

    Markert, K. N.; Limaye, A. S.; Rushi, B. R.; Adams, E. C.; Anderson, E.; Ellenburg, W. L.; Mithieu, F.; Griffin, R.

    2017-12-01

    Water resource management is the process by which governments, businesses and/or individuals reach and implement decisions that are intended to address the future quantity and/or quality of water for societal benefit. The implementation of water resource management typically requires the understanding of the quantity and/or timing of a variety of hydrologic variables (e.g. discharge, soil moisture and evapotranspiration). Often times these variables for management are simulated using hydrologic models particularly in data sparse regions. However, there are several large barriers to entry in learning how to use models, applying best practices during the modeling process, and selecting and understanding the most appropriate model for diverse applications. This presentation focuses on a multi-tiered approach to bring the state-of-the-art hydrologic modeling capabilities and methods to developing regions through the SERVIR program, a joint NASA and USAID initiative that builds capacity of regional partners and their end users on the use of Earth observations for environmental decision making. The first tier is a series of trainings on the use of multiple hydrologic models, including the Variable Infiltration Capacity (VIC) and Ensemble Framework For Flash Flood Forecasting (EF5), which focus on model concepts and steps to successfully implement the models. We present a case study for this in a pilot area, the Nyando Basin in Kenya. The second tier is focused on building a community of practice on applied hydrology modeling aimed at creating a support network for hydrologists in SERVIR regions and promoting best practices. The third tier is a hydrologic inter-comparison project under development in the SERVIR regions. The objective of this step is to understand model performance under specific decision-making scenarios, and to share knowledge among hydrologists in SERVIR regions. The results of these efforts include computer programs, training materials, and new

  9. Performance evaluation of an ejector subcooled vapor-compression refrigeration cycle

    International Nuclear Information System (INIS)

    Xing, Meibo; Yan, Gang; Yu, Jianlin

    2015-01-01

    Highlights: • An ejector subcooled vapor-compression refrigeration cycle is proposed. • The performance of the cycle with ejector subcooling is evaluated theoretically. • Increase in refrigeration capacity can be achieved by the ejector subcooled cycle. • The new cycle exhibits higher COP compared to the basic single-stage cycle. • Performance of the new cycle depends on the operation pressures of the ejector. - Abstract: In this study, a novel vapor-compression refrigeration cycle with mechanical subcooling using an ejector is proposed to improve the performance of a conventional single-stage vapor-compression refrigeration cycle. In the theoretical study, a mathematical model is developed to predict the performance of the cycle by using R404A and R290, and then compared with that of the conventional refrigeration cycle. The simulation results show that the performance of the ejector subcooled cycle is better than that of the conventional cycle. When the evaporator temperature ranges from −40 to −10 °C and the condenser temperature is 45 °C, the novel cycle displays volumetric refrigeration capacity improvements of 11.7% with R404A and 7.2% with R290. And the novel cycle achieves COP improvements of 9.5% with R404A and 7.0% with R290. In addition, the improvement of the COP and cooling capacity of this novel cycle largely depends on the operation pressures of the ejector. The potential practical advantages offered by the cycle may be worth further attention in future studies

  10. Building the institutional capacity for managing commercial high-level radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-05-01

    In July 1981, the Office of Nuclear Waste Management of the Department of Energy contracted with the National Academy of Public Administration for a study of institutional issues associated with the commercial radioactive waste management program. The two major sets of issues which the Academy was asked to investigate were (1) intergovernmental relationships, how federal, state, local and Indian tribal council governments relate to each other in the planning and implementation of a waste management program, and (2) interagency relationships, how the federal agencies with major responsibilities in this public policy arena interact with each other. The objective of the study was to apply the perspectives of public administration to a difficult and controversial question - how to devise and execute an effective waste management program workable within the constraints of the federal system. To carry out this task, the Academy appointed a panel composed of individuals whose background and experience would provide the several types of knowledge essential to the effort. The findings of this panel are presented along with the executive summary. The report consists of a discussion of the search for a radioactive waste management strategy, and an analysis of the two major groups of institutional issues: (1) intergovernmental, the relationship between the three major levels of government; and (2) interagency, the relationships between the major federal agencies having responsibility for the waste management program.

  11. Building the institutional capacity for managing commercial high-level radioactive waste

    International Nuclear Information System (INIS)

    1982-05-01

    In July 1981, the Office of Nuclear Waste Management of the Department of Energy contracted with the National Academy of Public Administration for a study of institutional issues associated with the commercial radioactive waste management program. The two major sets of issues which the Academy was asked to investigate were (1) intergovernmental relationships, how federal, state, local and Indian tribal council governments relate to each other in the planning and implementation of a waste management program, and (2) interagency relationships, how the federal agencies with major responsibilities in this public policy arena interact with each other. The objective of the study was to apply the perspectives of public administration to a difficult and controversial question - how to devise and execute an effective waste management program workable within the constraints of the federal system. To carry out this task, the Academy appointed a panel composed of individuals whose background and experience would provide the several types of knowledge essential to the effort. The findings of this panel are presented along with the executive summary. The report consists of a discussion of the search for a radioactive waste management strategy, and an analysis of the two major groups of institutional issues: (1) intergovernmental, the relationship between the three major levels of government; and (2) interagency, the relationships between the major federal agencies having responsibility for the waste management program

  12. Nonconvex model predictive control for commercial refrigeration

    Science.gov (United States)

    Gybel Hovgaard, Tobias; Boyd, Stephen; Larsen, Lars F. S.; Bagterp Jørgensen, John

    2013-08-01

    We consider the control of a commercial multi-zone refrigeration system, consisting of several cooling units that share a common compressor, and is used to cool multiple areas or rooms. In each time period we choose cooling capacity to each unit and a common evaporation temperature. The goal is to minimise the total energy cost, using real-time electricity prices, while obeying temperature constraints on the zones. We propose a variation on model predictive control to achieve this goal. When the right variables are used, the dynamics of the system are linear, and the constraints are convex. The cost function, however, is nonconvex due to the temperature dependence of thermodynamic efficiency. To handle this nonconvexity we propose a sequential convex optimisation method, which typically converges in fewer than 5 or so iterations. We employ a fast convex quadratic programming solver to carry out the iterations, which is more than fast enough to run in real time. We demonstrate our method on a realistic model, with a full year simulation and 15-minute time periods, using historical electricity prices and weather data, as well as random variations in thermal load. These simulations show substantial cost savings, on the order of 30%, compared to a standard thermostat-based control system. Perhaps more important, we see that the method exhibits sophisticated response to real-time variations in electricity prices. This demand response is critical to help balance real-time uncertainties in generation capacity associated with large penetration of intermittent renewable energy sources in a future smart grid.

  13. Manufacturing A Refrigerator with Heat Recovery Unit

    Directory of Open Access Journals (Sweden)

    Mustafa Mohammed Kadhim

    2018-02-01

    Full Text Available This study aims to exploite the rejected heating energy from condenser and benefit from it to reheat the foods and other materials. It can also be employed to improve the coefficient of performance of a refrigerator at the same time by using approximately the same consumption electrical energy used to operate the compressor and refrigerator in general. This idea has been implemented by manufacturing of a refrigerator with using additional part has the same metal and condenser pipe diameters but its surface area does not exceed 40% from total surface area of the condenser and its design as an insulated cabinet from all sides to prevent heat leakage through it and located between the compressor and the condenser. Small electrical fan has been added inside this cabinet to provide a suitable air circulation and a homogenous temperature distribution inside the cabinet space. It is expected that the super heating energy of refrigerant (R134a which comes out of the compressor would be removed  inside this cabinet and this insist to condensate the refrigerant (cooling fluid with a rate higher than that used in the normal refrigerator only. Three magnetic valves have been used in order to control the refrigerant flow in state of operation the refrigerator only or to gather with heating cabinet. To measure the temperatures at each process of the simple vapor compression refrigeration cycle, nine temperature sensors at input and output of each compressor, condenser and an evaporator in additional to input of cabinet and inside it and on evaporator surface have been provided. Five pressure gages have been used to measure the value of pressure and compare it for the two states of operation. The consumption of electrical energy  can be calculated by adding an ammeter and a voltmeter and compare between the consumption energy of both states. The obtained results show that there is an improvement in the coeffecient of performance in state of operation the

  14. Appendix 4. Documentation of sufficient capacity facility for spent nuclear fuel and radioactive waste management and its compliance with the decommissioning strategy and schedule

    International Nuclear Information System (INIS)

    2007-01-01

    In this chapter the documentation of sufficient capacity facility for spent nuclear fuel and radioactive waste management and its compliance with the decommissioning strategy and schedule of the NPP A-1 are presented.

  15. Energy performance of supermarket refrigeration and air conditioning integrated systems working with natural refrigerants

    International Nuclear Information System (INIS)

    Cecchinato, Luca; Corradi, Marco; Minetto, Silvia

    2012-01-01

    The current trends in commercial refrigeration aim at reducing the synthetic refrigerant charge, either by minimising the internal volume of the circuit or by utilising natural refrigerants, and at energy saving. The energy efficiency of supermarkets can be improved by optimising components design, recovering thermal and refrigerating energy, adopting innovative technology solutions, integrating the HVAC system with medium temperature and low temperature refrigeration plants and, finally, reducing thermal loads on refrigerated cases. This study aims at investigating the performance of different lay-out and technological solutions where only natural refrigerants are used and at finding the potential for improving energy efficiency over the traditional systems in different climates. In the analysis, chillers and heat pumps working with ammonia or propane, medium temperature systems working with ammonia or propane and carbon dioxide as heat transfer fluid or with carbon dioxide as the refrigerant and low temperature systems working with carbon dioxide are considered and benchmarked with a state-of-the-art HFCs based plant. The most efficient investigated solution enables an annual energy saving higher than 15% with respect to the baseline solution for all the considered climates. - Highlights: ► Different natural refrigerants supermarket HVAC and R integrated systems are analysed. ► Some of the proposed solutions offer a significant benefit over the baseline one. ► Up to 18.7% energy saving is achieved in the considered climates. ► The refrigeration unit condensation by the AC chiller offers the poorest results.

  16. Optimizing available water capacity using microwave satellite data for improving irrigation management

    Science.gov (United States)

    Gupta, Manika; Bolten, John; Lakshmi, Venkat

    2015-04-01

    This work addresses the improvement of available water capacity by developing a technique for estimating soil hydraulic parameters through the utilization of satellite-retrieved near surface soil moisture. The prototype involves the usage of Monte Carlo analysis to assimilate historical remote sensing soil moisture data available from the Advanced Microwave Scanning Radiometer (AMSR-E) within the hydrological model. The main hypothesis used in this study is that near-surface soil moisture data contain useful information that can describe the effective hydrological conditions of the basin such that when appropriately In the method followed in this study the hydraulic parameters are derived directly from information on the soil moisture state at the AMSR-E footprint scale and the available water capacity is derived for the root zone by coupling of AMSR-E soil moisture with the physically-based hydrological model. The available capacity water, which refers to difference between the field capacity and wilting point of the soil and represent the soil moisture content at 0.33 bar and 15 bar respectively is estimated from the soil hydraulic parameters using the van Genuchten equation. The initial ranges of soil hydraulic parameters are taken in correspondence with the values available from the literature based on Soil Survey Geographic (SSURGO) database within the particular AMSR-E footprint. Using the Monte Carlo simulation, the ranges are narrowed in the region where simulation shows a good match between predicted and near-surface soil moisture from AMSR-E. In this study, the uncertainties in accurately determining the parameters of the nonlinear soil water retention function for large-scale hydrological modeling is the focus of the development of the Bayesian framework. Thus, the model forecasting has been combined with the observational information to optimize the model state and the soil hydraulic parameters simultaneously. The optimization process is divided into

  17. Numerical model of sprayed air cooled condenser coupled to refrigerating system

    International Nuclear Information System (INIS)

    Youbi-Idrissi, M.; Macchi-Tejeda, H.; Fournaison, L.; Guilpart, J.

    2007-01-01

    Because of technological, economic and environmental constraints, many refrigeration and air conditioning units are equipped with a simple air cooled condenser. Spraying the condenser seems to be an original solution to improve the energetic performances of such systems. To characterise this energetic benefit, a semi-local mathematical model was developed and applied to a refrigerating machine with and without spraying its air cooled condenser. It is found that, compared to a dry air cooled condenser, both the calorific capacity and machine COP increase by 13% and 55%, respectively. Furthermore, the model shows that a spray flow rate threshold occurs. It should not be exceeded to assure an effective and rational spray use

  18. Inter-cooler in solar-assisted refrigeration system: Theory and experimental verification

    Directory of Open Access Journals (Sweden)

    Zheng Hui-Fan

    2015-01-01

    Full Text Available An inter-cooler in the solar-assisted refrigeration system was investigated experimentally and theoretically, and the theoretical prediction was fairly in good agreement with the experimental data. The influence of pipe diameter, tooth depth, and spiral angle of inter-cooler on the performance of the refrigerant system was analyzed. It was concluded that heat transfer is influenced deeply by the structure parameters of inter-cooler, and the heat transfer capacity increases with tooth depth and spiral angle increasing, and decreases with tooth apex angle increasing.

  19. Specification of Eight 2400 W @ 1.8 K Refrigeration Units for the LHC

    CERN Document Server

    Claudet, S; Jäger, B; Millet, F; Roussel, P; Tavian, L; Wagner, U

    2000-01-01

    The cooling capacity below 2 K for the superconducting magnets in the Large Hadron Collider (LHC), at CERN, will be provided by eight refrigeration units at 1.8 K, each of them coupled to a 4.5 K refrigerator. Taking into account the cryogenic architecture of the LHC and corresponding process design constraints, a reference solution based on a combination of cold centrifugal and warm volumetric compressors was established in 1997. The process and technical requirements expressed in the specification issued in 1998 and the procurement scenario based on pre-series acceptance prior to final series delivery between 2002 and 2004 are presented in this paper.

  20. Forest management under climatic and social uncertainty: trade-offs between reducing climate change impacts and fostering adaptive capacity.

    Science.gov (United States)

    Seidl, Rupert; Lexer, Manfred J

    2013-01-15

    The unabated continuation of anthropogenic greenhouse gas emissions and the lack of an international consensus on a stringent climate change mitigation policy underscore the importance of adaptation for coping with the all but inevitable changes in the climate system. Adaptation measures in forestry have particularly long lead times. A timely implementation is thus crucial for reducing the considerable climate vulnerability of forest ecosystems. However, since future environmental conditions as well as future societal demands on forests are inherently uncertain, a core requirement for adaptation is robustness to a wide variety of possible futures. Here we explicitly address the roles of climatic and social uncertainty in forest management, and tackle the question of robustness of adaptation measures in the context of multi-objective sustainable forest management (SFM). We used the Austrian Federal Forests (AFF) as a case study, and employed a comprehensive vulnerability assessment framework based on ecosystem modeling, multi-criteria decision analysis, and practitioner participation. We explicitly considered climate uncertainty by means of three climate change scenarios, and accounted for uncertainty in future social demands by means of three societal preference scenarios regarding SFM indicators. We found that the effects of climatic and social uncertainty on the projected performance of management were in the same order of magnitude, underlining the notion that climate change adaptation requires an integrated social-ecological perspective. Furthermore, our analysis of adaptation measures revealed considerable trade-offs between reducing adverse impacts of climate change and facilitating adaptive capacity. This finding implies that prioritization between these two general aims of adaptation is necessary in management planning, which we suggest can draw on uncertainty analysis: Where the variation induced by social-ecological uncertainty renders measures aiming to

  1. Building the institutional capacity for managing commercial high-level radioactive waste

    International Nuclear Information System (INIS)

    1982-05-01

    This report presents the findings and recommendations of an Academy panel formed to look into the major institutional issues associated with the commercial radioactive waste management program. The two major areas examined by the Panel were: (1) intergovernmental relationships, how federal, state, local and Indian tribal council governments relate to each other in the planning and implementation of a waste management program; and (2) interagency relationships, how the federal agencies with major responsibilities in this public policy arena interact with each other. The objective of the study was to apply the perspectives of public administration to a difficult and controversial question - how to devise and execute an effective waste management program workable within the constraints of the federal system

  2. Data-Driven Control of Refrigeration System

    DEFF Research Database (Denmark)

    Vinther, Kasper

    Refrigeration is used in a wide range of applications, e.g., for storage of food at low temperatures to prolong shelf life and in air conditioning for occupancy comfort. The main focus of this thesis is control of supermarket refrigeration systems. This market is very competitive and it is import......Refrigeration is used in a wide range of applications, e.g., for storage of food at low temperatures to prolong shelf life and in air conditioning for occupancy comfort. The main focus of this thesis is control of supermarket refrigeration systems. This market is very competitive...... traditionally are a pressure and a temperature sensor. In this thesis, a novel maximum slope-seeking (MSS) control method is developed. This has resulted in a control implementation, which successfully has been able to control the evaporator superheat in four widely different refrigeration system test...... problems. The method utilizes the qualitative nonlinearity in the system and harmonic analysis of a perturbation signal to reach an unknown, but suitable, operating point. Another important control task in refrigeration systems is to maintain the temperature of the refrigerated space or foodstuff within...

  3. Opportunities for strategic use of e-learning in scaling up disaster management capacity in Eastern Africa: a descriptive analysis.

    Science.gov (United States)

    William, Mayega Roy; Elzie, D; Sebuwufu, D; Kiguli, J; Bazeyo, W

    2013-06-01

    The growing need for disaster management skills at all levels in Eastern Africa requires innovative approaches to training planners at all levels. While information technology tools provide a viable option, few studies have assessed the capacity for training institutions to use technology for cascading disaster management skills. The design was an explorative survey. A pre-training survey was conducted among 16 faculty members (9 academic staff and 7 information technology (IT) staff) from 7 schools of public health in Eastern Africa. Key informant interviews with 4 students and 4 staff members were conducted at the school of public health in Makerere. IT staff also conducted observations on trends of use of information technology infrastructure. Current levels of use of ICT among teaching and IT staff is variable. On-site use of the internet is high, but off-site access is low. Personal computers, e-mail, discussion forums and other web-based learning management platforms and open education resources (OERs) have been variably used by faculty and students to facilitate learning. On the other hand, videos, web-conferencing, social media, web-based document management tools, and mobile telephone applications were much less frequently used. A disaster management short course produced by the Health Emergencies Management Project (HEMP) has been adapted to a web-based open education resource and an interactive CD-ROM. Challenges included low levels of awareness and skills in technology options among students and faculty and access to reliable internet. Despite the existing challenges, technology tools are a viable platform for cascading disaster management skills in Eastern Africa.

  4. 46 CFR 111.79-15 - Receptacles for refrigerated containers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Receptacles for refrigerated containers. 111.79-15... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-15 Receptacles for refrigerated containers. Receptacles for refrigerated containers must meet one of the following: (a) Each receptacle for refrigerated...

  5. Experts' Perceptions on China's Capacity to Manage Emerging and Re-emerging Zoonotic Diseases in an Era of Climate Change.

    Science.gov (United States)

    Hansen, A; Xiang, J; Liu, Q; Tong, M X; Sun, Y; Liu, X; Chen, K; Cameron, S; Hanson-Easey, S; Han, G-S; Weinstein, P; Williams, C; Bi, P

    2017-11-01

    Zoonotic diseases transmitted by arthropods and rodents are a major public health concern in China. However, interventions in recent decades have helped lower the incidence of several diseases despite the country's large, frequently mobile population and socio-economic challenges. Increasing globalization, rapid urbanization and a warming climate now add to the complexity of disease control and prevention and could challenge China's capacity to respond to threats of emerging and re-emerging zoonoses. To investigate this notion, face-to-face interviews were conducted with 30 infectious disease experts in four cities in China. The case study diseases under discussion were malaria, dengue fever and haemorrhagic fever with renal syndrome, all of which may be influenced by changing meteorological conditions. Data were analysed using standard qualitative techniques. The study participants viewed the current disease prevention and control system favourably and were optimistic about China's capacity to manage climate-sensitive diseases in the future. Several recommendations emerged from the data including the need to improve health literacy in the population regarding the transmission of infectious diseases and raising awareness of the health impacts of climate change amongst policymakers and health professionals. Participants thought that research capacity could be strengthened and human resources issues for front-line staff should be addressed. It was considered important that authorities are well prepared in advance for outbreaks such as dengue fever in populous subtropical areas, and a prompt and coordinated response is required when outbreaks occur. Furthermore, health professionals need to remain skilled in the identification of diseases for which incidence is declining, so that re-emerging or emerging trends can be rapidly identified. Recommendations such as these may be useful in formulating adaptation plans and capacity building for the future control and

  6. Governance and Capacity to Manage Resilience of Health Systems: Towards a New Conceptual Framework

    Directory of Open Access Journals (Sweden)

    Karl Blanchet

    2017-08-01

    Full Text Available The term resilience has dominated the discourse among health systems researchers since 2014 and the onset of the Ebola outbreak in West Africa. There is wide consensus that the global community has to help build more resilient health systems. But do we really know what resilience means, and do we all have the same vision of resilience? The present paper presents a new conceptual framework on governance of resilience based on systems thinking and complexity theories. In this paper, we see resilience of a health system as its capacity to absorb, adapt and transform when exposed to a shock such as a pandemic, natural disaster or armed conflict and still retain the same control over its structure and functions.

  7. Energy efficient refrigeration and flexible power consumption in a smart grid

    Energy Technology Data Exchange (ETDEWEB)

    Gybel Hovgaard, T.; Larsen, Lars F.S. (Danfoss Refrigeration and A/C Controls, Nordborg (Denmark)); Halvgaard, R.; Bagterp Joergensen, J. (Technical Univ. of Denmark (DTU). DTU Informatics, Kgs. Lyngby (Denmark))

    2011-05-15

    Refrigeration and heating systems consume substantial amounts of energy worldwide. However, due to the thermal capacity there is a potential for storing 'coldness' or heat in the system. This feature allows for implementation of different load shifting and shedding strategies in order to optimize the operation energywise, but without compromising the original cooling and indoor climate quality. In this work we investigate the potential of such a strategy and its ability to significantly lower the cost related to operating systems such as supermarket refrigeration and heat pumps for residential houses. With modern Economic Model Predictive Control (MPC) methods we make use of weather forecasts and predictions of varying electricity prices to apply more load to the system when the thermodynamic cycle is most efficient, and to consume larger shares of the electricity when the demand and thereby the prices are low. The ability to adjust power consumption according to the demands on the power grid is a highly wanted feature in a future Smart Grid. Efficient utilization of greater amounts of renewable energy calls for solutions to control the power consumption such that it increases when an energy surplus is available and decreases when there is a shortage. This should happen almost instantly to accommodate intermittent energy sources as e.g. wind turbines. We expect our power management solution to render systems with thermal storage capabilities suitable for flexible power consumption. The aggregation of several units will contribute significantly to the shedding of total electricity demand. Using small case studies we demonstrate the potential for utilizing daily variations to deliver a power efficient cooling or heating and for the implementation of Virtual Power Plants in Smart Grid scenarios. (Author)

  8. Load forecasting of supermarket refrigeration

    DEFF Research Database (Denmark)

    Rasmussen, Lisa Buth; Bacher, Peder; Madsen, Henrik

    2016-01-01

    methods for predicting the regimes are tested. The dynamic relation between the weather and the load is modeled by simple transfer functions and the non-linearities are described using spline functions. The results are thoroughly evaluated and it is shown that the spline functions are suitable...... for handling the non-linear relations and that after applying an auto-regressive noise model the one-step ahead residuals do not contain further significant information....... in Denmark. Every hour the hourly electrical load for refrigeration is forecasted for the following 42 h. The forecast models are adaptive linear time series models. The model has two regimes; one for opening hours and one for closing hours, this is modeled by a regime switching model and two different...

  9. Bearing construction for refrigeration compresssor

    Science.gov (United States)

    Middleton, Marc G.; Nelson, Richard T.

    1988-01-01

    A hermetic refrigeration compressor has a cylinder block and a crankshaft rotatable about a vertical axis to reciprocate a piston in a cylinder on the cylinder block. A separate bearing housing is secured to the central portion of the cylinder block and extends vertically along the crankshaft, where it carries a pair of roller bearings to journal the crankshaft. The crankshaft has a radially extending flange which is journaled by a thrust-type roller bearing above the bearing housing to absorb the vertical forces on the crankshaft so that all three of the roller bearings are between the crankshaft and the bearing housing to maintain and control the close tolerances required by such bearings.

  10. PIPER Continuous Adiabatic Demagnetization Refrigerator

    Science.gov (United States)

    Kimball, Mark O.; Shirron, Peter J.; Canavan, Edgar R.; James, Bryan L.; Sampson, Michael A.; Letmate, Richard V.

    2017-01-01

    We report upon the development and testing of a 4-stage adiabatic demagnetization refrigerator (ADR) capable of continuous cooling at 0.100 Kelvin. This cooler is being built to cool the detector array aboard NASA's Primordial Inflation Polarization Explorer (PIPER) observatory. The goal of this balloon mission is to measure the primordial gravitational waves that should exist if the theory of cosmological inflation is correct. At altitude, the ADR will hold the array of transition-edge sensors at 100 mK continuously while periodically rejecting heat to a 1.2 K pumped helium bath. During testing on ground, the array is held at the same temperature but heat is rejected to a 4.2 K helium bath indicating the flexibility in this coolers design.

  11. Role-Playing Games for Capacity Building in Water and Land Management: Some Brazilian Experiences

    Science.gov (United States)

    Camargo, Maria Eugenia; Jacobi, Pedro Roberto; Ducrot, Raphaele

    2007-01-01

    Role-playing games in natural resource management are currently being tested as research, training, and intervention tools all over the world. Various studies point out their potential to deal with complex issues and to contribute to training processes. The objective of this contribution is to analyze the limits and potentialities of this tool for…

  12. Using Role-Play to Enhance Foodborne Illness Crisis Management Capacity in the Produce Industry

    Science.gov (United States)

    Kreske, Audrey; Ducharme, Diane; Gunter, Chris; Phister, Trevor

    2013-01-01

    Foodborne illness outbreaks have measurable public health effects and often lead to negative produce industry impacts. Reducing loss following a crisis event requires a management plan, although many fresh produce industry members don't have one. Evidence-based workshops using a role-play simulated outbreak were delivered to impact crisis…

  13. CSIR NYENDA programme: traffic management R&D capacity building - balancing the opportunities and constraints

    CSIR Research Space (South Africa)

    Labuschagne, FJJ

    2009-07-01

    Full Text Available The CSIR's NyendaWeb programme is developed to provide support to the road safety and traffic management fraternity particularly to efforts aimed at stopping the carnage on South African roads and then also to achieve sustainability in transport...

  14. A Successful Replication of the River Visitor Inventory and Monitoring Process for Capacity Management

    Science.gov (United States)

    Kenneth Chilman; James Vogel; Greg Brown; John H. Burde

    2004-01-01

    This paper has 3 purposes: to discuss 1. case study research and its utility for recreation management decisionmaking, 2. the recreation visitor inventory and monitoring process developed from case study research, and 3. a successful replication of the process in a large-scale, multi-year application. Although case study research is discussed in research textbooks as...

  15. Capacity development for community health nurses in Pakistan: the assistant manager role.

    Science.gov (United States)

    Gulzar, S A; Mistry, R; Upvall, M J

    2011-09-01

    Community health nurses (CHNs), as leaders in developing countries, can promote successful outcomes in meeting the targets of the Millennium Development Goals. A community-based organization in Pakistan is striving to achieve the goals of maternal and child health through the development of the assistant manager role for community health nursing. The purpose of this study was to assess the perception of the role of the CHN assistant manager, with the goal of strengthening that role. This interpretive, qualitative study included 13 participants already familiar with CHNs in Pakistan. Interviewing was utilized to explore perceptions of the assistant manager role and to uncover challenges currently existing within this new role. Content analysis revealed the following themes: 'role perceptions', 'expectations of the role' and 'collaboration with other community healthcare providers'. Changes to the role are necessary including increased education of the assistant manager CHNs and preparing administration to work with the assistant mangers for effective leadership. © 2011 The Authors. International Nursing Review © 2011 International Council of Nurses.

  16. Building chronic disease management capacity in General Practice: The South Australian GP Plus Practice Nurse Initiative.

    Science.gov (United States)

    Fuller, Jeffrey; Koehne, Kristy; Verrall, Claire C; Szabo, Natalie; Bollen, Chris; Parker, Sharon

    2015-01-01

    This paper draws on the implementation experience of the South Australian GP Plus Practice Nurse Initiative in order to establish what is needed to support the development of the chronic disease management role of practice nurses. The Initiative was delivered between 2007 and 2010 to recruit, train and place 157 nurses across 147 General Practices in Adelaide. The purpose was to improve chronic disease management in General Practice, by equipping nurses to work as practice nurses who would coordinate care and establish chronic disease management systems. Secondary analysis of qualitative data contained in the Initiative evaluation report, specifically drawing on quarterly project records and four focus groups conducted with practice nurses, practice nurse coordinators and practice nurse mentors. As evidenced by the need to increase the amount of support provided during the implementation of the Initiative, nurses new to General Practice faced challenges in their new role. Nurses described a big learning curve as they dealt with role transition to a new work environment and learning a range of new skills while developing chronic disease management systems. Informants valued the skills development and support offered by the Initiative, however the ongoing difficulties in implementing the role suggested that change is also needed at the level of the Practice. While just over a half of the placement positions were retained, practice nurses expressed concern with having to negotiate the conditions of their employment. In order to advance the role of practice nurses as managers of chronic disease support is needed at two levels. At one level support is needed to assist practice nurses to build their own skills. At the level of the Practice, and in the wider health workforce system, support is also needed to ensure that Practices are organisationally ready to include the practice nurse within the practice team.

  17. Classification of refrigerants; Classification des fluides frigorigenes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This document was made from the US standard ANSI/ASHRAE 34 published in 2001 and entitled 'designation and safety classification of refrigerants'. This classification allows to clearly organize in an international way the overall refrigerants used in the world thanks to a codification of the refrigerants in correspondence with their chemical composition. This note explains this codification: prefix, suffixes (hydrocarbons and derived fluids, azeotropic and non-azeotropic mixtures, various organic compounds, non-organic compounds), safety classification (toxicity, flammability, case of mixtures). (J.S.)

  18. Two-phase flow in refrigeration systems

    CERN Document Server

    Gu, Junjie; Gan, Zhongxue

    2013-01-01

    Two-Phase Flow in Refrigeration Systems presents recent developments from the authors' extensive research programs on two-phase flow in refrigeration systems. This book covers advanced mass and heat transfer and vapor compression refrigeration systems and shows how the performance of an automotive air-conditioning system is affected through results obtained experimentally and theoretically, specifically with consideration of two-phase flow and oil concentration. The book is ideal for university postgraduate students as a textbook, researchers and professors as an academic reference book, and b

  19. Behavior of FFC refrigerants in the presence of refrigerant oils. Oelverhalten chlorfreier Kaeltemittel

    Energy Technology Data Exchange (ETDEWEB)

    Burke, M.; Kruse, H. (Hannover Univ. (Germany, F.R.). Inst. fuer Kaeltetechnik und Angewandte Waermetechnik)

    1990-01-01

    Looking for substitutes for the ozone-depleting refrigerants R12 and R22, investigations were made of the miscibility of FFC refrigerants (R23 - trifluoromethane CHF{sub 3}, R134a - tetrafluoroethane CH{sub 3}-CHF{sub 2}, and R152a - difluoroethane CH{sub 3}-CHF{sub 2}) with refrigerator oils. First experimental results reveal the refrigerants' behavior when mixed with mineral oils, alkylbenzene, PAG and ester-based oils. Mixtures of above refrigerants, especially R134a/R152a and R23/R152a as binary nonazeotropic mixtures, are considered conceivable substitutes. While addition of R23 reduces the mixture's flammability, addition of R152a improves the solubility of R134a in refrigerant oils. (orig./HW).

  20. Need for capacity building and knowledge management in nuclear applications, an IAEA perspective

    International Nuclear Information System (INIS)

    Haug, P.

    2004-01-01

    Full text: It is a great pleasure for me to welcome you to this conference on behalf of co-organisers FORATOM, the Brussels-based trade association for Europe's nuclear energy sector. My sincere thanks go to the main organisers, the IAEA and the CEA, for allowing me this opportunity to speak about the European industry perspective on what is a crucial aspect of the sector's current operation and its future. I would first like to outline FORATOM's relationship to nuclear knowledge management, and then go on to describe what motivates our members in this extremely important field. Although all the activities of FORATOM involve knowledge in one form or another, it is not involved in knowledge management in the sense that is assumed for this conference. We deal mainly with matters of policy, which means that the knowledge we manage is current and not expected to have a long shelf life. However, some of our working groups and task forces play a knowledge management role that serves company specialists in particular fields. I refer here, in particular, to: 1) our Business Excellence Working Group, previously known as the Quality Management Working Group, and 2) the R and D Working Group. Through these working groups, our members are given an opportunity to tackle the issues of knowledge preservation and expansion. It is clear that knowledge management stretches into every facet of the nuclear sector - nuclear plant control rooms, personnel training centres, research labs, company boardrooms and among regulators, national nuclear associations and nuclear societies. For the nuclear industry, both in Europe and the rest of the world, the overriding priority and preoccupation is safety. And it is in the safety field that knowledge management therefore has its most crucial role to play. Lapses in safety, due to loss of knowledge, would have severe consequences for the industry, so the importance of maintaining and updating the industry's skills base and know-how should never

  1. A thematic analysis of the role of the organisation in building allied health research capacity: a senior managers' perspective.

    Science.gov (United States)

    Golenko, Xanthe; Pager, Susan; Holden, Libby

    2012-08-27

    Evidence-based practice aims to achieve better health outcomes in the community. It relies on high quality research to inform policy and practice; however research in primary health care continues to lag behind that of other medical professions. The literature suggests that research capacity building (RCB) functions across four levels; individual, team, organisation and external environment. Many RCB interventions are aimed at an individual or team level, yet evidence indicates that many barriers to RCB occur at an organisational or external environment level. This study asks senior managers from a large healthcare organisation to identify the barriers and enablers to RCB. The paper then describes strategies for building allied health (AH) research capacity at an organisational level from a senior managers' perspective. This qualitative study is part of a larger collaborative RCB project. Semi-structured in-depth interviews were conducted with nine allied health senior managers. Recorded interviews were transcribed and NVivo was used to analyse findings and emergent themes were defined. The dominant themes indicate that the organisation plays an integral role in building AH research capacity and is the critical link in creating synergy across the four levels of RCB. The organisation can achieve this by incorporating research into its core business with a whole of organisation approach including its mission, vision and strategic planning. Critical success factors include: developing a co-ordinated and multidisciplinary approach to attain critical mass of research-active AH and enhance learning and development; support from senior managers demonstrated through structures, processes and systems designed to facilitate research; forming partnerships to increase collaboration and sharing of resources and knowledge; and establishing in internal framework to promote recognition for research and career path opportunities. This study identifies four key themes: whole of

  2. Energy shift estimation of demand response activation on domestic refrigerators – A field test study

    DEFF Research Database (Denmark)

    Lakshmanan, Venkatachalam; Gudmand-Høyer, Kristian; Marinelli, Mattia

    2014-01-01

    This paper presents a method to estimate the amount of energy that can be shifted during demand response (DR) activation on domestic refrigerator. Though there are many methods for DR activation like load reduction, load shifting and onsite generation, the method under study is load shifting....... Electric heating and cooling equipment like refrigerators, water heaters and space heaters and coolers are preferred for such DR activation because of their energy storing capacity. Accurate estimation of available regulating power and energy shift is important to understand the value of DR activation...... at any time. In this paper a novel method to estimate the available energy shift from domestic refrigerators with only two measurements, namely fridge cool chamber temperature and compressor power consumption is proposed, discussed and evaluated....

  3. Synchronous compartment temperature control and apparatus for refrigeration with reduced energy consumption

    Science.gov (United States)

    Gomes, Alberto Regio; Keres, Stephen L.; Kuehl, Stephen J.; Litch, Andrew D.; Richmond, Peter J.; Wu, Guolian

    2015-09-22

    A refrigerator appliance configuration, and associated methods of operation, for an appliance with a controller, a condenser, at least one evaporator, a compressor, and two refrigeration compartments. The configuration may be equipped with a variable-speed or variable-capacity compressor, variable speed evaporator or compartment fans, a damper and/or a dual-temperature evaporator with a valve system to control flow of refrigerant through one or more pressure reduction devices. The controller, by operation of the compressor, fans, damper and/or valve system, depending on the appliance configuration, controls the cooling rate in one or both compartments to synchronize, alternating cycles of cooling the compartments to their set point temperatures.

  4. Combined Brayton-JT cycles with refrigerants for natural gas liquefaction

    Science.gov (United States)

    Chang, Ho-Myung; Park, Jae Hoon; Lee, Sanggyu; Choe, Kun Hyung

    2012-06-01

    Thermodynamic cycles for natural gas liquefaction with single-component refrigerants are investigated under a governmental project in Korea, aiming at new processes to meet the requirements on high efficiency, large capacity, and simple equipment. Based upon the optimization theory recently published by the present authors, it is proposed to replace the methane-JT cycle in conventional cascade process with a nitrogen-Brayton cycle. A variety of systems to combine nitrogen-Brayton, ethane-JT and propane-JT cycles are simulated with Aspen HYSYS and quantitatively compared in terms of thermodynamic efficiency, flow rate of refrigerants, and estimated size of heat exchangers. A specific Brayton-JT cycle is suggested with detailed thermodynamic data for further process development. The suggested cycle is expected to be more efficient and simpler than the existing cascade process, while still taking advantage of easy and robust operation with single-component refrigerants.

  5. Numerical modelling and analysis of a room temperature magnetic refrigeration system

    DEFF Research Database (Denmark)

    Petersen, Thomas Frank

    This thesis presents a two-dimensional mathematical model of an Active Magnetic Regenerator (AMR) system which is used for magnetic refrigeration at room temperature. The purpose of the model is to simulate a laboratory-scale AMR constructed at Risø National Laboratory. The AMR model geometry....... The AMR performs a cyclic process, and to simulate the AMR refrigeration cycle the model starts from an initial temperature distribution in the regenerator and fluid channel and takes time steps forward in time until the cyclical steady-state is obtained. The model can therefore be used to study both...... transient and steady-state phenomena. The AMR performance can be evaluated in terms of the no-load temperature span as well as the refrigeration capacity and the COP. The AMR model was verified extensively and it was concluded that the model has energy conservation and that the solution is independent...

  6. Digital Repositories of Learning Material as a Support Tool for Knowledge Management and Capacity Building

    International Nuclear Information System (INIS)

    Marmonti, E.

    2016-01-01

    Full text: For some years, digital repositories are emerging as a de facto standard service for storing, preserving and disseminate knowledge: academic, scientific information and, more recently, primary research data of institutions. Some of the digital repositories host also collections of material classified as learning objects; some others are created to manage only learning objects (LO), as the Learning Objects Digital Repositories, or were built to function as learning objects aggregators. The term “learning object” itself is involving different types of structures, organization and complexity. This paper will show how digital repositories, metadata standards and semantic web technologies can be valuable tools for managing educational content, which can contribute to build a learning and knowledge driven organization. (author

  7. Cross case analysis of institutions and adaptive capacity in The Netherlands: Do institutions for spatial planning, water and nature management in The Netherlands enhance the capacity of society to adapt to climate change?

    NARCIS (Netherlands)

    Meijerink, S.; Bergsma, E.; Gupta, J.; Jong, P.; Klostermann, J.E.M.; Termeer, C.J.A.M.

    2010-01-01

    In this working document we aim to answer the following question: Do institutions for spatial planning, water and nature management in the Netherlands enhance the capacity of society to adapt to climate change? To answer this question we have first reviewed the literature on adaptive governance and

  8. New magnetic refrigeration materials for the liquefaction of hydrogen

    International Nuclear Information System (INIS)

    Gschneidner, K.A.; Takeya, H.; Moorman, J.O.; Pecharsky, V.K.; Malik, S.K.; Zimm, C.B.

    1994-01-01

    Five heavy lanthanide ferromagnetic intermetallic compounds were studied as potential magnetic refrigerants for the liquefaction of hydrogen gas. (Dy 0.5 Er 0.5 )Al 2 and TbNi 2 appear to be better refrigerants than GdPd for a Joule-Brayton cycle refrigerator, while (Gd 0.54 Er 0.46 )AlNi seems to be a suitable refrigerant for an Ericsson cycle refrigerator

  9. 2014 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2014-01-01

    The proceedings of the 2014 German refrigeration and air conditioning meeting contain contributions on the following topics: cryotechnology, fundamentals and materials for the refrigeration and heat pump technology, devices and components for the refrigeration and heat pump technology, applications of refrigeration technologies, air conditioning technology and heat pump applications, cryotechnology in biology and medicine, heat transfer and ventilation, guidelines and legal topics, refrigerant fluid - oil mixtures, control and surveillance, simulation and control, ambient air.

  10. Application of Cascade Refrigeration System with Mixing Refrigerant in Cold Air Cutting

    Science.gov (United States)

    Yang, Y.; Tong, M. W.; Yang, G.; Wang, X. P.

    In the mechanical cutting process, the replacement of traditional cutting solution with cold air can avoid the pollution of environment. In order to high efficient the refrigerating device and flexible adjust the temperature of cold air, it is necessary to use cascade refrigeration system to supply cool quantity for the compressed air. The introduction of a two-component non-azeotropic mixing refrigerant into the cryogenic part of the cascade system, can effectively solve the problems of the system working at too high pressure and the volume expanding of refrigerant in case of the cascade refrigeration sets closed down. However, the filling ratio of mixing refrigerants impact on the relationships among the closing down pressure, refrigerating output and refrigerating efficiency. On the basis of computing and experiment, the optimal mixing ratio of refrigerant R22/R13 and a low temperature of -60° were obtained in this study. A cold air injecting device possessing high efficiency in energy saving has also been designed and manufactured. The cold air, generated from this cascade system and employed in a cutting process, takes good comprehensive effects on machining and cutting.

  11. Short-term oleoyl-estrone treatment affects capacity to manage lipids in rat adipose tissue

    Directory of Open Access Journals (Sweden)

    Remesar Xavier

    2007-08-01

    Full Text Available Abstract Background Short-term OE (oleoyl-estrone treatment causes significant decreases in rat weight mainly due to adipose tissue loss. The aim of this work was to determine if OE treatment affects the expression of genes that regulate lipid metabolism in white adipose tissue. Results Gene expression in adipose tissue from female treated rats (48 hours was analysed by hybridization to cDNA arrays and levels of specific mRNAs were determined by real-time PCR. Treatment with OE decreased the expression of 232 genes and up-regulated 75 other genes in mesenteric white adipose tissue. The use of real-time PCR validate that, in mesenteric white adipose tissue, mRNA levels for Lipoprotein Lipase (LPL were decreased by 52%, those of Fatty Acid Synthase (FAS by 95%, those of Hormone Sensible Lipase (HSL by 32%, those of Acetyl CoA Carboxylase (ACC by 92%, those of Carnitine Palmitoyltransferase 1b (CPT1b by 45%, and those of Fatty Acid Transport Protein 1 (FATP1 and Adipocyte Fatty Acid Binding Protein (FABP4 by 52% and 49%, respectively. Conversely, Tumour Necrosis Factor (TNFα values showed overexpression (198%. Conclusion Short-term treatment with OE affects adipose tissue capacity to extract fatty acids from lipoproteins and to deal with fatty acid transport and metabolism.

  12. Short-term oleoyl-estrone treatment affects capacity to manage lipids in rat adipose tissue.

    Science.gov (United States)

    Salas, Anna; Noé, Véronique; Ciudad, Carlos J; Romero, M Mar; Remesar, Xavier; Esteve, Montserrat

    2007-08-28

    Short-term OE (oleoyl-estrone) treatment causes significant decreases in rat weight mainly due to adipose tissue loss. The aim of this work was to determine if OE treatment affects the expression of genes that regulate lipid metabolism in white adipose tissue. Gene expression in adipose tissue from female treated rats (48 hours) was analysed by hybridization to cDNA arrays and levels of specific mRNAs were determined by real-time PCR. Treatment with OE decreased the expression of 232 genes and up-regulated 75 other genes in mesenteric white adipose tissue. The use of real-time PCR validate that, in mesenteric white adipose tissue, mRNA levels for Lipoprotein Lipase (LPL) were decreased by 52%, those of Fatty Acid Synthase (FAS) by 95%, those of Hormone Sensible Lipase (HSL) by 32%, those of Acetyl CoA Carboxylase (ACC) by 92%, those of Carnitine Palmitoyltransferase 1b (CPT1b) by 45%, and those of Fatty Acid Transport Protein 1 (FATP1) and Adipocyte Fatty Acid Binding Protein (FABP4) by 52% and 49%, respectively. Conversely, Tumour Necrosis Factor (TNFalpha) values showed overexpression (198%). Short-term treatment with OE affects adipose tissue capacity to extract fatty acids from lipoproteins and to deal with fatty acid transport and metabolism.

  13. Management of electricity network cross border capacity: allocation procedures between France and Belgium

    International Nuclear Information System (INIS)

    Raytchev, D.

    2003-01-01

    This paper tries to identify a method of allocation of the Interconnector capacity for the transport of electricity which complies best with the (conflicting) interests of users, system operators and regulators in the context of a common European market of electricity. The first part combines a historical approach with a comparative study of existing allocation procedures to show that the new joint mechanism of auctioning and market splitting, applied to the whole northern zone of UCTE is vastly superior to the existing allocation arrangement on the Franco-Belgian border. The second part discusses some problems related to the implementation of the new allocation mechanism. Here we examine some difficulties concerning ca achy auctioning (like auction methods and organisation, profit distribution and derivative markets) as well as the market splitting method (neutrality, markets without power exchanges, etc). The main obstacle facing the new method remains however the lack of willingness to address the urgent issue of reforming the present allocation procedures- a remnant from the period of centrally planned electricity systems where neighbouring monopoly companies negotiated agreements of mutual assistance. These agreements are currently kept in place by tacit inaction despite their heterogeneity and arbitrariness which slow down the emergence of a real competition capable of contesting the positions of historic operators. (authors)

  14. Study on the coupling performance of a turboexpander compressor applied in cryogenic reverse Brayton air refrigerator

    International Nuclear Information System (INIS)

    Yang, Shanju; Chen, Shuangtao; Chen, Xingya; Zhang, Xingqun; Hou, Yu

    2016-01-01

    Highlights: • Numerical simulations on expansion and compression processes were carried out. • A coupling model was built based on analysis and simulation and verified by test. • Relations and interactions among coupling parameters were quantitatively described. • When T_0_C = 0.39 MPa, the cooling capacity of refrigerator reached 221 W at 129.6 K. - Abstract: A small cryogenic reverse Brayton air refrigerator with turboexpander compressor (TEC) is presented in this study. Because of stable process, simple matching between expander and brake blower, and easy regulation, a turboexpander with brake blower is usually used in small reverse Brayton refrigerator. However, a turboexpander with brake blower just consumes and wastes the output energy during the enthalpy drop. In contrast, the output energy of TEC is absorbed by its coupled compressor for recycling. Thus when employing a TEC, the reverse Brayton refrigerator will achieve lower refrigeration temperature, larger cooling capacity and more effective energy use. TEC overall performance, which has an important impact on the refrigerator thermal performance, is mainly determined by the coupling between expander and compressor. In a TEC, the compressor and expander should seek balance among energy, rotating speed, mass flow rate and pressure, though restricted by individual working characteristics. The coupling relations among compressor efficiency, expander efficiency, compressor pressure ratio and expander expansion ratio are quite complex. In this study, theoretical coupling analysis between expander and compressor was conducted. The aerodynamic performances of compressor and expander were calculated using CFX simulation with SST model. The performance curves of compressor and expander were obtained through simulation results, which were validated by experimental data. Based on the coupling analysis and numerical simulations, the automatic coupling model between compression process and expansion process

  15. ENERGY STAR Certified Commercial Refrigerators and Freezers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Commercial Refrigerators and Freezers that are...

  16. ENERGY STAR Laboratory Grade Refrigerators and Freezers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.0 ENERGY STAR Program Requirements for Laboratory Grade Refrigerators and Freezers that...

  17. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  18. Defrost Temperature Termination in Supermarket Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

    2011-11-01

    The objective of this project was to determine the potential energy savings associated with implementing demand defrost strategies to defrost supermarket refrigerated display case evaporators, as compared to the widely accepted current practice of controlling display case defrost cycles with a preset timer. The defrost heater energy use of several representative display case types was evaluated. In addition, demand defrost strategies for refrigerated display cases as well as those used in residential refrigerator/freezers were evaluated. Furthermore, it is anticipated that future work will include identifying a preferred defrost strategy, with input from Retail Energy Alliance members. Based on this strategy, a demand defrost system will be designed which is suitable for supermarket refrigerated display cases. Limited field testing of the preferred defrost strategy will be performed in a supermarket environment.

  19. Auto-refrigerating cascade for superconducting applications

    International Nuclear Information System (INIS)

    Forrest, S.M.; Hall, P.H.; Missimer, D.J.

    1987-01-01

    Extremely low temperatures, in the range of 230 to 90 K, are achieved in a single circuit compression refrigeration system operated by a conventional compressor. The system relies upon a series of intermediate cooling stages. The refrigerant is a mixture and the system employs fractional condensation, distillation, phase separation and intermediate heat transfer. Each stage includes the steps of withdrawing a portion of the liquid condensate from the compressed vapor-liquid refrigerant mixture which enters the stage. The withdrawn condensate is then throttled to a lower pressure and is mixed with the refrigerant being recycled to the compressor from the final evaporator. Evaporating the throttled condensate absorbs heat from and at least partially condenses the compressed uncondensed vapor in the compressed mixture

  20. ACTIVATED CARBON/REFRIGERANT COMBINATIONS FOR ...

    African Journals Online (AJOL)

    ES Obe

    2001-03-01

    Mar 1, 2001 ... to solar adsorption refrigeration machines are estimated. ... heat, activated carbon/ammonia requires the use of advanced flat-plate collectors such as those with multiple ... the thermodynamic performance of zeolite-water.

  1. Freezing and refrigerated storage in fisheries

    National Research Council Canada - National Science Library

    Johnston, W. A

    1994-01-01

    ...; the factors affecting cold storage conditions, etc. In addition, the publication describes the methods used to calculate cold storage refrigeration loads as well as the costs of freezing and cold storage...

  2. Simulation of the Energy Saver refrigeration system

    International Nuclear Information System (INIS)

    Barton, H.R. Jr.; Nicholls, J.E.; Mulholland, G.T.

    1981-10-01

    The helium refrigeration for the Energy Saver is supplied by a Central Helium Liquefier and 24 Satellite Refrigerators installed over a 1-1/4 square mile area. An interactive, software simulator has been developed to calculate the refrigeration available from the cryogenic system over a wide range of operating conditions. The refrigeration system simulator incorporates models of the components which have been developed to quantitatively describe changes in system performance. The simulator output is presented in a real-time display which has been used to search for the optimal operating conditions of the Satellite-Central system, to examine the effect of an extended range of operating parameters and to identify equipment modifications which would improve the system performance

  3. Urgency of Capacity Building in Local Finance Management on Decentralization Era (The Dynamic of Parking Taxes Management at Banguntapan District, Bantul Region DI Yogyakarta Province

    Directory of Open Access Journals (Sweden)

    Bambang Sunaryo

    2014-12-01

    Full Text Available Capacity building of local finance management becomes important on decentralizations era. Empirically this research is aim to show that the parking tax management at glance seen as an administrative- procedural policy domain cannot release from phenomena on the existence of problematic pathology for regional financial management. District of Bantul Banguntapan characteristic as its suburbs form the main attraction in the selection of research because of the general locus in sub-urban area, began to metamorphose into a parking tax revenues from regions that contribute to the area though not as big financial contribution income tax parking tax in urban areas. The Banguntapan sub district was chosen as analysis unit in this research to represent the issue of parking tax management in sub urban area of Bantul. This was due to the characteristic of Bantul area as sub urban area that can be seen from the characteristics of sub urban in Banguntapan sub district. Moreover, the Banguntapan sub district is the only area in Bantul which has a parking tax subject that the cost is self-assessment and flat thus the dynamic of local finance managing problems can be observed and in-depth analysed in Banguntapan sub district to seek the comparison of those 2 parking tax collection systems.

  4. Commercial refrigeration - An overview of current status

    OpenAIRE

    Mota Babiloni, Adrián; Navarro Esbri, Joaquin; BARRAGÁN CERVERA, ÁNGEL; Moles, Francisco; Peris, Bernardo; Verdú Martín, Gumersindo Jesús

    2015-01-01

    Commercial Refrigeration comprises food freezing and conservation in retail stores and supermarkets, so, it is one of the most relevant energy consumption sectors, and its relevance is increasing. This paper reviews the most recent developments in commercial refrigeration available in literature and presents a good amount of results provided these systems, covering some advantages and disadvantages in systems and working fluids. Latest researches are focused on energy savings to reduce CO2 in...

  5. A review of linear compressors for refrigeration

    OpenAIRE

    Liang, Kun

    2017-01-01

    Linear compressor has no crank mechanism compared with conventional reciprocating compressor. This allows higher efficiency, oil-free operation, lower cost and smaller size when linear compressors are used for vapour compression refrigeration (VCR) system. Typically, a linear compressor consists of a linear motor (connected to a piston) and suspension springs, operated at resonant frequency. This paper presents a review of linear compressors for refrigeration system. Different designs and mod...

  6. A miniature adsorption3HE refrigerator

    International Nuclear Information System (INIS)

    Duband, L.; Ravex, A.; Lange, A.

    1991-01-01

    A self-contained, recyclable laboratory 3 He refrigerator has been developed. The refrigerator is very compact, portable and is designed to be safe and reliable. The unit can easily be installed on the cold plate of a superfluid 4 He cryostat. Once bolted on the cold plate, operation of the refrigerator is controlled by a single heater. In this new design the refrigerator has a cylindrical geometry. The adsorption pump is placed above the condensation point to prevent convection during the condensation phase and to improve the pumping speed. The inhibition of convection reduces the load on the 4 He bath and increases the condensation efficiency. This refrigeration technique has great potential for space applications. The absence of moving parts makes the system reliable and vibration free. Its simplicity and the absence of external components facilitate its integration on a cryostat. In fact, a rocket-borne 3 He refrigerator has already been successfully flown and has demonstrated the feasibility of this method

  7. Optimizing the Thermoacoustic Pulse Tube Refrigerator Performances

    Directory of Open Access Journals (Sweden)

    E. V. Blagin

    2014-01-01

    Full Text Available The article deals with research and optimization of the thermoacoustic pulse tube refrigerator to reach a cryogenic temperature level. The refrigerator is considered as a thermoacoustic converter based on the modified Stirling cycle with helium working fluid. A sound pressure generator runs as a compressor. Plant model comprises an inner heat exchanger, a regenerative heat exchanger, a pulse tube, hot and cold heat exchangers at its ends, an inertial tube with the throttle, and a reservoir. A model to calculate the pulse tube thermoacoustic refrigerator using the DeltaEC software package has been developed to be a basis for calculation techniques of the pulse tube refrigerator. Momentum, continuity, and energy equations for helium refrigerant are solved according to calculation algorithm taking into account the porosity of regenerator and heat exchangers. Optimization of the main geometric parameters resulted in decreasing temperature of cold heat exchanger by 41,7 K. After optimization this value became equal to 115,01 K. The following parameters have been optimized: diameters of the feeding and pulse tube and heat exchangers, regenerator, lengths of the regenerator and pulse and inertial tubes, as well as initial pressure. Besides, global minimum of temperatures has been searched at a point of local minima corresponding to the optimal values of abovementioned parameters. A global-local minima difference is 0,1%. Optimized geometric and working parameters of the thermoacoustic pulse tube refrigerator are presented.

  8. Computer modeling of commercial refrigerated warehouse facilities

    International Nuclear Information System (INIS)

    Nicoulin, C.V.; Jacobs, P.C.; Tory, S.

    1997-01-01

    The use of computer models to simulate the energy performance of large commercial refrigeration systems typically found in food processing facilities is an area of engineering practice that has seen little development to date. Current techniques employed in predicting energy consumption by such systems have focused on temperature bin methods of analysis. Existing simulation tools such as DOE2 are designed to model commercial buildings and grocery store refrigeration systems. The HVAC and Refrigeration system performance models in these simulations tools model equipment common to commercial buildings and groceries, and respond to energy-efficiency measures likely to be applied to these building types. The applicability of traditional building energy simulation tools to model refrigerated warehouse performance and analyze energy-saving options is limited. The paper will present the results of modeling work undertaken to evaluate energy savings resulting from incentives offered by a California utility to its Refrigerated Warehouse Program participants. The TRNSYS general-purpose transient simulation model was used to predict facility performance and estimate program savings. Custom TRNSYS components were developed to address modeling issues specific to refrigerated warehouse systems, including warehouse loading door infiltration calculations, an evaporator model, single-state and multi-stage compressor models, evaporative condenser models, and defrost energy requirements. The main focus of the paper will be on the modeling approach. The results from the computer simulations, along with overall program impact evaluation results, will also be presented

  9. Water Resource Management Mechanisms for Intrastate Violent Conflict Resolution: the Capacity Gap and What To Do About It.

    Science.gov (United States)

    Workman, M.; Veilleux, J. C.

    2014-12-01

    Violent conflict and issues surrounding available water resources are both global problems and are connected. Violent conflict is increasingly intrastate in nature and coupled with increased hydrological variability as a function of climate change, there will be increased pressures on water resource use. The majority of mechanisms designed to secure water resources are often based on the presence of a governance framework or another type of institutional capacity, such as offered through a supra- or sub-national organization like the United Nations or a river basin organization. However, institutional frameworks are not present or loose functionality during violent conflict. Therefore, it will likely be extremely difficult to secure water resources for a significant proportion of populations in Fragile and Conflict Affected States. However, the capacity in Organisation for Economic Co-operation and Development nations for the appropriate interventions to address this problem is reduced by an increasing reluctance to participate in interventionist operations following a decade of expeditionary warfighting mainly in Iraq and Afghanistan, and related defence cuts. Therefore, future interventions in violent conflict and securing water resources may be more indirect in nature. This paper assesses the state of understanding key areas in the present literature and highlights the gap of securing water resources during violent conflict in the absence of institutional capacity. There is a need to close this gap as a matter of urgency by formulating frameworks to assess the lack of institutional oversight / framework for water resources in areas where violent conflict is prevalent; developing inclusive resource management platforms through transparency and reconciliation mechanisms; and developing endogenous confidence-building measures and evaluate how these may be encouraged by exogenous initiatives including those facilitated by the international community. This effort

  10. Helium Inventory Management For LHC Cryogenics

    CERN Document Server

    Pyarali, Maisam

    2017-01-01

    The LHC is a 26.7 km circumference ring lined with superconducting magnets that operate at 1.9 K. These magnets are used to control the trajectory of beams of protons traveling in opposite directions and collide them at various experimental sites across the LHC where their debris is analyzed. The focus of this paper is the cryogenic system that allows the magnets to operate in their superconducting states. It aims to highlight the operating principles of helium refrigeration and liquefaction, with and without nitrogen pre-cooling; discuss the various refrigerators and liquefiers used at CERN for both LHC and Non-LHC applications, with their liquefaction capacities and purposes; and finally to deliberate the management of the LHC inventory and how it contributes to the strategic decision CERN makes regarding the inventory management during the Year-End Technical Stop (YETS), Extended Year-End Technical Stop (EYETS) and long shutdowns.

  11. NASA's Indigenous Capacity Building Initiative: Balancing Traditional Knowledge and Existing Remote Sensing Training to Inform Management Decisions

    Science.gov (United States)

    McCullum, A. J. K.; Schmidt, C.; Palacios, S. L.; Ly, V.

    2017-12-01

    NASA's Indigenous Capacity Building Initiative is aimed to provide remote sensing training, mentoring, and research opportunities to the indigenous community. A key programmatic goal is the co-production of place-based trainings where participants have the opportunity to address specific natural resource research and management issues facing their tribal lands. Three primary strategies have been adopted to engage with our tribal partners, these include: (1) the use of existing tribal networks and conferences such as the National Tribal GIS Conference, (2) coordination with other federal agencies such as the Bureau of Indian Affairs (BIA) and tribal liaisons at regional Climate Science Centers, and (3) connecting with tribes directly. Regional partner visits with tribes, such as meetings with the Samish Indian Nation, are integral to cultivate trusting, collaborative, and sustained partnerships and an understanding of how Earth Observations can be applied to the unique set of challenges and goals each tribe faces. As the program continues to grow, we aim to increase our incorporation of Traditional Ecological Knowledge (TEK) into technical methods and to develop trainings tailored to thematic areas of interest to specific tribes. Engagement and feedback are encouraged to refine our approaches to increase capacity within the indigenous community to utilize NASA Earth Observations.

  12. Revenue Management in Make-To-Order Manufacturing: Case Study of Capacity Control at ThyssenKrupp VDM

    Directory of Open Access Journals (Sweden)

    André Hintsches

    2010-10-01

    Full Text Available While revenue management (RM is traditionally considered a tool of service operations, RM shows considerable potential for application in manufacturing operations. The typical challenges in make-to-order manufacturing are fixed manufacturing capacities and a great variety in offered products, going along with pronounced fluctuations in demand and profitability. Since Harris and Pinder in the mid-90s, numerous papers have furthered the understanding of RM theory in this environment. Nevertheless, results to be expected from applying the developed methods to a practical industry setting have yet to be reported. To this end, this paper investigates a possible application of RM at ThyssenKrupp VDM, leading to considerable improvements in several areas.

  13. Building capacity for water, sanitation, and hygiene programming: Training evaluation theory applied to CLTS management training in Kenya.

    Science.gov (United States)

    Crocker, Jonny; Shields, Katherine F; Venkataramanan, Vidya; Saywell, Darren; Bartram, Jamie

    2016-10-01

    Training and capacity building are long established critical components of global water, sanitation, and hygiene (WaSH) policies, strategies, and programs. Expanding capacity building support for WaSH in developing countries is one of the targets of the Sustainable Development Goals. There are many training evaluation methods and tools available. However, training evaluations in WaSH have been infrequent, have often not utilized these methods and tools, and have lacked rigor. We developed a conceptual framework for evaluating training in WaSH by reviewing and adapting concepts from literature. Our framework includes three target outcomes: learning, individual performance, and improved programming; and two sets of influences: trainee and context factors. We applied the framework to evaluate a seven-month community-led total sanitation (CLTS) management training program delivered to 42 government officials in Kenya from September 2013 to May 2014. Trainees were given a pre-training questionnaire and were interviewed at two weeks and seven months after initial training. We qualitatively analyzed the data using our conceptual framework. The training program resulted in trainees learning the CLTS process and new skills, and improving their individual performance through application of advocacy, partnership, and supervision soft skills. The link from trainees' performance to improved programming was constrained by resource limitations and pre-existing rigidity of trainees' organizations. Training-over-time enhanced outcomes and enabled trainees to overcome constraints in their work. Training in soft skills is relevant to managing public health programs beyond WaSH. We make recommendations on how training programs can be targeted and adapted to improve outcomes. Our conceptual framework can be used as a tool both for planning and evaluating training programs in WaSH. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Experimental study on the performance of the vapor injection refrigeration system with an economizer for intermediate pressures

    Science.gov (United States)

    Moon, Chang-Uk; Choi, Kwang-Hwan; Yoon, Jung-In; Kim, Young-Bok; Son, Chang-Hyo; Ha, Soo-Jung; Jeon, Min-Ju; An, Sang-Young; Lee, Joon-Hyuk

    2018-04-01

    In this study, to investigate the performance characteristics of vapor injection refrigeration system with an economizer at an intermediate pressure, the vapor injection refrigeration system was analyzed under various experiment conditions. As a result, the optimum design data of the vapor injection refrigeration system with an economizer were obtained. The findings from this study can be summarized as follows. The mass flow rate through the compressor increases with intermediate pressure. The compression power input showed an increasing trend under all the test conditions. The evaporation capacity increased and then decreased at the intermediate pressure, and as such, it became maximum at the given intermediate pressure. The increased mass flow rate of the by-passed refrigerant enhanced the evaporation capacity at the low medium pressure range, but the increased saturation temperature limited the subcooling degree of the liquid refrigerant after the application of the economizer when the intermediate pressure kept rising, and degenerated the evaporation capacity. The coefficient of performance (COP) increased and then decreased with respect to the intermediate pressures under all the experiment conditions. Nevertheless, there was an optimum intermediate pressure for the maximum COP under each experiment condition. Therefore, the optimum intermediate pressure in this study was found at -99.08 kPa, which is the theoretical standard medium pressure under all the test conditions.

  15. Need for capacity building and knowledge management in nuclear applications, an IAEA perspective

    International Nuclear Information System (INIS)

    Rossbach, M.

    2004-01-01

    In view of an aging workforce and an increasing lack of students interested in nuclear technology and sciences many reports have pinpointed to the crucial situation in loosing valuable expertise and urged for the initiation of capable programmes to revitalize training opportunities and public interests in nuclear subjects. Several international and national initiatives emerged to support education and training in nuclear engineering and radiochemistry but it appears that money alone is not sufficient to reverse the trend. Nuclear knowledge management concepts and strategies have been discussed at various levels but a clear picture how to attract more interest in nuclear activities in the young generation did not emerge so far. It seems that only concerted action including social, political, scientific and technical components can positively change public perception of nuclear applications and, hence, result in an increased interest of students to take up this subject and embark in a professional life as a nuclear scientist or engineer. The Department of Nuclear Sciences and Applications (NA) of the IAEA is trying to support - through many different mechanisms - training and education in the nuclear sector and enhance the dissemination of nuclear knowledge from advanced to less advanced countries. Some of the more recent activities of the Department will be described in this communication. (author)

  16. Capacity of Health Facilities to Manage Hypertension in Mukono and Buikwe Districts in Uganda: Challenges and Recommendations.

    Science.gov (United States)

    Musinguzi, Geofrey; Bastiaens, Hilde; Wanyenze, Rhoda K; Mukose, Aggrey; Van Geertruyden, Jean-Pierre; Nuwaha, Fred

    2015-01-01

    The burden of chronic diseases is increasing in both low- and middle-income countries. However, healthcare systems in low-income countries are inadequately equipped to deal with the growing disease burden, which requires chronic care for patients. The aim of this study was to assess the capacity of health facilities to manage hypertension in two districts in Uganda. In a cross-sectional study conducted between June and October 2012, we surveyed 126 health facilities (6 hospitals, 4 Health Center IV (HCIV), 23 Health Center III (HCIII), 41 Health Center II (HCII) and 52 private clinics/dispensaries) in Mukono and Buikwe districts in Uganda. We assessed records, conducted structured interviews with heads of facilities, and administered questionnaires to 271 health workers. The study assessed service provision for hypertension, availability of supplies such as medicines, guidelines and equipment, in-service training for hypertension, knowledge of hypertension management, challenges and recommendations. Of the 126 health facilities, 92.9% reported managing (diagnosing/treating) patients with hypertension, and most (80.2%) were run by non-medical doctors or non-physician health workers (NPHW). Less than half (46%) of the facilities had guidelines for managing hypertension. A 10th of the facilities lacked functioning blood pressure devices and 28% did not have stethoscopes. No facilities ever calibrated their BP devices except one. About a half of the facilities had anti-hypertensive medicines in stock; mainly thiazide diuretics (46%), beta blockers (56%) and calcium channel blockers (48.4%). Alpha blockers, mixed alpha & beta blockers and angiotensin II receptor antagonists were only stocked by private clinics/dispensaries. Most HCIIs lacked anti-hypertensive medicines, including the first line thiazide diuretics. Significant knowledge gaps in classification of patients as hypertensive were noted among respondents. All health workers (except 5, 1.9%) indicated that they

  17. Improving the energy efficiency of industrial refrigeration systems

    International Nuclear Information System (INIS)

    Oh, Jin-Sik; Binns, Michael; Park, Sangmin; Kim, Jin-Kuk

    2016-01-01

    Various retrofit design options are available for improving the energy efficiency and economics of industrial refrigeration systems. This study considers a novel retrofit option using a mixed refrigerant (MR) in refrigeration cycles designed for use with a pure refrigerant (PR). In this way energy savings can be realized by switching refrigerants without requiring extensive and expensive reconfiguration of equipment. Hence, the aim here is to test the common thinking that equipment should always be extensively reconfigured when switching from pure to mixed refrigerants. To determine the most energy-efficient operating conditions for each refrigeration design an optimization framework is utilized linking a process simulator with an external optimization method. A case study is presented to demonstrate how the proposed process modeling and optimization framework can be applied and to illustrate the economic benefits of using the retrofit design options considered here. For the case considered in this paper, savings of shaft power required for the refrigeration cycle can be achieved from 16.3% to 27.2% when the pure refrigerant is replaced with mixed refrigerants and operating conditions are re-optimized. - Highlights: • Design methods for the design of refrigeration cycles in retrofit cases. • Consideration of mixed refrigerants to the existing multi-level pure-refrigerant cycles. • Optimization of refrigeration cycles with integrated use of a process simulator with an optimizer.

  18. ENERGY EFFICIENCY, ENERGY SAVING POTENTIAL AND ENVIRONMENTAL IMPACT RESEARCH OF LPG CARRIER REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    V. О. Bedrosov

    2016-12-01

    Full Text Available Nowadays energy efficiency improvement and global warming are issues of current interest because of the natural resources depletion and extreme climate change. Thus, the problem of formation of strict regulations regarding emissions into the air arises. This paper presents the study of cascade refrigeration system for re-condensing of associated petroleum gas during sea transportation for LPG carrier. The structural optimization has been performed. LPG gas carriers with 266 000 m3 ethane capacity require 15 MW cascade refrigeration system for re-condensing if the temperature in the coastal LPG storage is -70°C, and the temperature for transported Ethan is maintained at  -75°C. For current storage conditions the required system cooling capacity is only 1,078 MW intended for the heat gain rejection from the environment during Ethane transportation. The replacement of ozone-depleting refrigerant R22 to alternative agents: R407C, R404A, R402A, R717, R290, R1270 was estimated. The results of analysis have shown that the proposed improvements can be used to optimize the LPG carrier cascade refrigeration system

  19. Exergoeconomic performance optimization for a steady-flow endoreversible refrigeration model including six typical cycles

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lingen; Kan, Xuxian; Sun, Fengrui; Wu, Feng [College of Naval Architecture and Power, Naval University of Engineering, Wuhan 430033 (China)

    2013-07-01

    The operation of a universal steady flow endoreversible refrigeration cycle model consisting of a constant thermal-capacity heating branch, two constant thermal-capacity cooling branches and two adiabatic branches is viewed as a production process with exergy as its output. The finite time exergoeconomic performance optimization of the refrigeration cycle is investigated by taking profit rate optimization criterion as the objective. The relations between the profit rate and the temperature ratio of working fluid, between the COP (coefficient of performance) and the temperature ratio of working fluid, as well as the optimal relation between profit rate and the COP of the cycle are derived. The focus of this paper is to search the compromised optimization between economics (profit rate) and the utilization factor (COP) for endoreversible refrigeration cycles, by searching the optimum COP at maximum profit, which is termed as the finite-time exergoeconomic performance bound. Moreover, performance analysis and optimization of the model are carried out in order to investigate the effect of cycle process on the performance of the cycles using numerical example. The results obtained herein include the performance characteristics of endoreversible Carnot, Diesel, Otto, Atkinson, Dual and Brayton refrigeration cycles.

  20. Relationship between composition of mixture charged and that in circulation in an auto refrigerant cascade and a J-T refrigerator operating in liquid refrigerant supply mode

    Science.gov (United States)

    Sreenivas, Bura; Nayak, H. Gurudath; Venkatarathnam, G.

    2017-01-01

    The composition of the refrigerant mixture in circulation during steady state operation of J-T and allied refrigerators is not the same as that charged due to liquid hold up in the heat exchangers and phase separators, as well as the differential solubility of different refrigerant components in the compressor lubricating oil. The performance of refrigerators/liquefiers operating on mixed refrigerant cycles is dependent on the mixture composition. It is therefore important to charge the right mixture that results in an optimum composition in circulation during steady state operation. The relationship between the charged and circulating composition has been experimentally studied in a J-T refrigerator operating in the liquid refrigerant supply (LRS) mode and an auto refrigerant cascade refrigerator (with a phase separator) operating in the gas refrigerant supply (GRS) mode. The results of the study are presented in this work. The results show that the method presented earlier for J-T refrigerators operating in GRS mode is also applicable in the case of refrigerators studied in this work.

  1. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P [ELF Atochem, Centre d` Application de Lavallois, 92 (France)

    1998-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  2. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P. [ELF Atochem, Centre d`Application de Lavallois, 92 (France)

    1997-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  3. Suitability criterion for a refrigerant for use in solar operated sorption refrigerator

    International Nuclear Information System (INIS)

    Tabassum, S.A.; Mir, M.S.

    1996-01-01

    The thermodynamics of a sorption refrigeration cycle has been discussed representing the cycle on a clapeyron digram. The minimum generation temperature required has been determined using the 'd-a' equation which represents the sorption equilibrium of the pair, and Gibbs free energy relation. The mathematical relation developed provides a totally new basis for determination of suitability of a particular refrigerant. (author)

  4. Suitability criterion for a refrigerant for use in solar operated sorption refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Tabassum, S A; Mir, M S [University of Engineering and Technology, Lahore (Pakistan). Dept. of Mechanical Engineering

    1996-06-01

    The thermodynamics of a sorption refrigeration cycle has been discussed representing the cycle on a clapeyron digram. The minimum generation temperature required has been determined using the `d-a` equation which represents the sorption equilibrium of the pair, and Gibbs free energy relation. The mathematical relation developed provides a totally new basis for determination of suitability of a particular refrigerant. (author).

  5. Review of magnetic refrigeration system as alternative to conventional refrigeration system

    Science.gov (United States)

    Mezaal, N. A.; Osintsev, K. V.; Zhirgalova, T. B.

    2017-10-01

    The refrigeration system is one of the most important systems in industry. Developers are constantly seeking for how to avoid the damage to the environment. Magnetic refrigeration is an emerging, environment-friendly technology based on a magnetic solid that acts as a refrigerant by magneto-caloric effect (MCE). In the case of ferromagnetic materials, MCE warms as the magnetic moments of the atom are aligned by the application of a magnetic field. There are two types of magnetic phase changes that may occur at the Curie point: first order magnetic transition (FOMT) and second order magnetic transition (SOMT). The reference cycle for magnetic refrigeration is AMR (Active Magnetic Regenerative cycle), where the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. Regeneration can be accomplished by blowing a heat transfer fluid in a reciprocating fashion through the regenerator made of magnetocaloric material that is alternately magnetized and demagnetized. Many magnetic refrigeration prototypes with different designs and software models have been built in different parts of the world. In this paper, the authors try to shed light on the magnetic refrigeration and show its effectiveness compared with conventional refrigeration methods.

  6. A new compressed air energy storage refrigeration system

    International Nuclear Information System (INIS)

    Wang Shenglong; Chen Guangming; Fang Ming; Wang Qin

    2006-01-01

    In this study, a new compressed air energy storage (CAES) refrigeration system is proposed for electrical power load shifting application. It is a combination of a gas refrigeration cycle and a vapor compression refrigeration cycle. Thermodynamic calculations are conducted to investigate the performance of this system. Economic analysis is performed to study the operating cost of the system, and comparison is made with a vapor compression refrigeration system and an ice storage refrigeration system. The results indicate that the CAES refrigeration system has the advantages of simple structure, high efficiency and low operating cost

  7. ARTI refrigerant database. Quarterly report, March--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1997-05-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information an older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date.

  8. Optimization of a cascade refrigeration system using refrigerant C_3H_8 in high temperature circuits (HTC) and a mixture of C_2H_6/CO_2 in low temperature circuits (LTC)

    International Nuclear Information System (INIS)

    Nasruddin; Sholahudin, S.; Giannetti, N.; Arnas

    2016-01-01

    Highlights: • Multi-objective optimization is conducted in the cascade refrigeration system. • Combination of operating temperature and refrigerant performance has been studied. • Characteristic of C_3H_8 and a mixture of C_2H_6/CO_2 have been investigated. • Determining of CO_2 fraction to optimize refrigeration system has been done. - Abstract: This paper discusses the multi-objectives optimization of a cascade refrigeration system using refrigerant C_3H_8 in high temperature circuits (HTC) and a mixture of C_2H_6/CO_2 in low temperature circuits (LTC). The evaporator temperature, condenser temperature, C_2H_6/CO_2 mixture condensation temperature, cascade temperature differences, and the CO_2 mass fraction are chosen as the decision variables. Whereas cooling capacity, cold space temperature, and ambient temperature are taken as the constraints. The purpose of this research is to design a cascade refrigeration system whose optimum performance are defined in terms of economics and thermodynamics. Accordingly, there are two objective functions that should be simultaneously optimized including the total annual cost which consists of the capital and operational cost and the total exergy destruction of the system. To this aim, the optimum operating temperature of the system and CO_2 fraction should be determined so that the system has minimum exergy destruction and annual cost. Results show that, the optimum value of the decision variables for this system can be determined by trade-off between annual cost and exergy destruction.

  9. Capacity, responsibility, and motivation: a critical qualitative evaluation of patient and practitioner views about barriers to self-management in people with multimorbidity.

    Science.gov (United States)

    Coventry, Peter A; Fisher, Louise; Kenning, Cassandra; Bee, Penny; Bower, Peter

    2014-10-31

    Primary care is increasingly focussed on the care of people with two or more long-term conditions (multimorbidity). The UK Department of Health strategy for long term conditions is to use self-management support for the majority of patients but there is evidence of limited engagement among primary care professionals and patients with multimorbidity. Furthermore, multimorbidity is more common in areas of socioeconomic deprivation but deprivation may act as a barrier to patient engagement in self-management practices. Effective self-management is considered critical to meet the needs of people living with long term conditions but achieving this is a significant challenge in patients with multimorbidity. This study aimed to explore patient and practitioner views on factors influencing engagement in self-management in the context of multimorbidity. A qualitative study using individual semi-structured interviews with 20 patients and 20 practitioners drawn from four general practices in Greater Manchester situated in areas of high and low social deprivation. Three main factors were identified as influencing patient engagement in self-management: capacity (access and availability of socio-economic resources and time; knowledge; and emotional and physical energy), responsibility (the degree to which patients and practitioners agreed about the division of labour about chronic disease management, including self-management) and motivation (willingness to take-up types of self-management practices). Socioeconomic deprivation negatively impacted on all three factors. Motivation was especially reduced in the presence of mental and physical multimorbidity. Full engagement in self-management practices in multimorbidity was only present where patients' articulated a sense of capacity, responsibility, and motivation. Patient 'know-how' or interpretive capacity to self-manage multimorbidity is potentially an important precursor to responsibility and motivation, and might be a

  10. A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius

    Science.gov (United States)

    Dreepaul, R. K.

    2017-11-01

    The most frequently used refrigerants in the refrigeration and air conditioning (RAC) sector in Mauritius are currently hydrochlorofluorocarbons (HCFC) and hydrofluorocarbons (HFC). However, because of their strong influence on global warming and the impact of HCFCs on the ozone layer, refrigerants such as ammonia (NH3), carbon dioxide (CO2) and Hydrocarbons (HC), having minimal impact on the environment, are being considered. So far, HCs have only been safely used in domestic refrigeration. Ammonia has been used mainly for industrial refrigeration whereas CO2 is still under study. In this paper, a comparative study of the various feasible alternatives is presented in a survey that was undertaken with major stake holders in the field. The retrofitting possibility of existing equipment was assessed and safety issues associated with each refrigerant were analysed. The major setback of hydrocarbons as a widely accepted refrigerant is its flammability which was considered as a major safety hazard by the majority of respondents in the survey and the main advantages are the improved equipment coefficient of performance (COP) and better TEWI factor. This resulted in a 12 % drop in energy consumption. Despite the excellent thermodynamic properties of ammonia, its use has mainly been confined to industrial refrigeration due to its toxicity. In Mauritius, the performance of ammonia in air conditioning is being evaluated on a pilot basis. The major setback of carbon dioxide as a refrigerant is the high operating pressure which is considered a safety hazard. The high initial investment cost and the lack of qualified maintenance technician is also an issue. The use of CO2 is mainly being considered in the commercial refrigeration sector.

  11. Ultimate refrigerating conditions, behavior turning and a thermodynamic analysis for absorption–compression hybrid refrigeration cycle

    International Nuclear Information System (INIS)

    Zheng Danxing; Meng Xuelin

    2012-01-01

    Highlights: ► Two novel fundamental concepts of the absorption refrigeration cycle were proposed. ► The interaction mechanism of compressor pressure increasing with other key-parameters was investigated. ► A set of optimal operating condition of hybrid refrigeration cycle was found. ► A simulation and investigation for R134a-DMF hybrid refrigeration cycle was performed. - Abstract: The absorption–compression hybrid refrigeration cycle has been considered as an effective approach to reduce the mechanical work consumption by using low-grade heat, such as solar energy. This work aims at studying the thermodynamic mechanism of the hybrid refrigeration cycle. Two fundamental concepts have been proposed, which are the ultimate refrigerating temperature (or the ultimate temperature lift) and the behavior turning. On the basis of that, the interaction mechanism of compressor pressure increasing with other key-parameters and the impact of compressor pressure increasing on the cycle performance have been investigated. The key-parameters include the concentration difference, the circulation ratio of working fluid, etc. The work points out that the hybrid refrigeration cycle performance varies with the change of compressor outlet pressure and depends on which one achieves dominance in the hybrid refrigeration cycle, the absorption sub-system or the compression sub-system. The behavior turning point during parameters changing corresponds to a maximum value of the heat powered coefficient of performance. In this case, the hybrid refrigeration cycle performance is optimal because the low-grade heat utilization is the most effective. In addition, to validate the theoretical analysis, a solar hybrid refrigeration cycle with R134a–DMF as working pair was simulated. The Peng–Robinson equation of state was adopted to calculate thermophysical properties when the reliability assessment of the prediction models on the available literature data of R134a–DMF system had been

  12. Zero boil-off methods for large-scale liquid hydrogen tanks using integrated refrigeration and storage

    Science.gov (United States)

    Notardonato, W. U.; Swanger, A. M.; E Fesmire, J.; Jumper, K. M.; Johnson, W. L.; Tomsik, T. M.

    2017-12-01

    NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multilayer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

  13. Cooling performance and energy saving of a compression-absorption refrigeration system driven by a gas engine

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z.G.; Guo, K.H. [Sun Yat-Sen University, Guangzhou (China). Engineering School

    2006-07-01

    The prototype of combined vapour compression-absorption refrigeration system was set up, where a gas engine drove directly an open screw compressor in a vapour compression refrigeration chiller and waste heat from the gas engine was used to operate absorption refrigeration cycle. The experimental procedure and results showed that the combined refrigeration system was feasible. The cooling capacity of the prototype reached about 589 kW at the Chinese rated conditions of air conditioning (the inlet and outlet temperatures of chilled water are 12 and 7{sup o}C, the inlet and outlet temperatures of cooling water are 30 and 35{sup o}C, respectively). Primary energy rate (PER) and comparative primary energy saving were used to evaluate energy utilization efficiency of the combined refrigeration system. The calculated results showed that the PER of the prototype was about 1.81 and the prototype saved more than 25% of primary energy compared to a conventional electrically driven vapour compression refrigeration unit. Error analysis showed that the total error of the combined cooling system measurement was about 4.2% in this work. (author)

  14. An experimental investigation on the substitution of HFC134a with HFO1234YF in a domestic refrigerator

    International Nuclear Information System (INIS)

    Aprea, Ciro; Greco, Adriana; Maiorino, Angelo

    2016-01-01

    Highlights: • An experimental comparison between R134A and HFO1234YF is presented. • A domestic refrigerator made to work with R134A is analysed. • The annual energy consumptions of the device are reported. • The energy saving achievable after the drop-in is evaluated. - Abstract: The latest international regulations on the reduction of greenhouse gases are strongly redesigning the scenario of use of refrigerants, gradually eliminating the possibility of employing the HFCs. Among all sectors of refrigeration, one of the most affected by these restrictions is the domestic refrigeration. Although for it have been suggested some solutions, such as the construction of household refrigerator operating with the hydrocarbons, there remains the need to find a substitute for HFC134a. In particular, the substitution may involve both existing machines and already in operation, which cannot be loaded with hydrocarbons, and new devices. With the aim of finding a simple implementation solution, in the present work, it is reported an experimental investigation carried out on a domestic refrigerator designed and built to operate with HFC134a and for which a drop-in with HFO1234yf has been realised. The experimentation has been addressed so as to highlight the behaviour of the system as a result of the drop-in, with a particular interest in the energy performance variation. A slight energy saving has been recorded with HFO1234yf, and an improving of the cooling capacity has been noticed.

  15. Building partnership capacity for the collaborative management of marine protected areas in the UK: a preliminary analysis.

    Science.gov (United States)

    Jones, Peter J S; Burgess, Jacquelin

    2005-11-01

    This paper reports the findings of a preliminary analysis of 15 case studies of inshore marine protected areas in the UK. It draws on the common-pool resource (CPR) literature and is premised on the thesis that building partnership capacity amongst relevant authorities and resource users provides a critical basis for overcoming collective action problems (CAPs), through the development of incentive structures and social capital, in order to achieve strategic objectives. Particular attention is paid to the influence of statutory marine biodiversity conservation obligations to the European Commission for marine special areas of conservation (MSACs), as these are an important external contextual factor. The risks of imposition and parochialism are outlined and the challenges of taking a balanced approach are discussed. The challenges posed by the attributes of the marine environment are considered, as are those posed by the policy framework for MSACs. The findings are discussed in relation to three questions: (i) which partnership models appear to have the potential to overcome the CAPs posed by inshore MSACs? (ii) what CAPs had to be addressed during the early phase of development of the MSAC co-management regimes? (iii) what are the likely future CAPs for the collaborative management of MSACs that each partnership will need to address? These preliminary findings will form the basis for future studies to analyse the outcomes of these 15 initiatives, in order to assess the strengths, in various contexts, of different approaches for building resilient and balanced, thereby effective, institutions for the co-management of MSACs in the UK.

  16. Capacity Building

    International Nuclear Information System (INIS)

    Molloy, Brian; Mallick, Shahid

    2014-01-01

    Outcomes & Recommendations: • Significant increase needed in the nuclear workforce both to replace soon-to-retire current generation and to staff large numbers of new units planned • Key message, was the importance of an integrated approach to workforce development. • IAEA and other International Organisations were asked to continue to work on Knowledge Management, Networks and E&T activities • IAEA requested to conduct Global Survey of HR needs – survey initiated but only 50% of operating countries (30% of capacity) took part, so results inconclusive

  17. Influence of Oil on Refrigerant Evaporator Performance

    Science.gov (United States)

    Kim, Jong-Soo; Nagata, Karsuya; Katsuta, Masafumi; Tomosugi, Hiroyuki; Kikuchi, Kouichiro; Horichi, Toshiaki

    In vapor compression refrigeration system using oil-lubricated compressors, some amount of oil is always circulated through the system. Oil circulation can have a significant influence on the evaporator performance of automotive air conditioner which is especially required to cool quickly the car interior after a period standing in the sun. An experimental investigation was carried out an electrically heated horizontal tube to measure local heat transfer coefficients for various flow rates and heat fluxes during forced convection boiling of pure refrigerant R12 and refrigerant-oil mixtures (0-11% oil concentration by weight) and the results were compared with oil free performance. Local heat transfer coefficients increased at the region of low vapor quality by the addition of oil. On the other hand, because the oil-rich liquid film was formed on the heat transfer surface, heat transfer coefficients gradually decreased as the vapor quality became higher. Average heat transfer coefficient reached a maximum at about 4% oil concentration and this trend agreed well with the results of Green and Furse. Previous correlations, using the properties of the refrigerant-oil mixture, could not predict satisfactorily the local heat transfer coefficients data. New correlation modified by oil concentration factor was developed for predicting the corresponding heat transfer coefficient for refrigerant-oil mixture convection boiling. The maximum percent deviation between predicted and measured heat transfer coefficient was within ±30%.

  18. A Comparative Cycle and Refrigerant Simulation Procedure Applied on Air-Water Heat Pumps

    DEFF Research Database (Denmark)

    Mader, Gunda; Palm, Björn; Elmegaard, Brian

    2012-01-01

    A vapor compression heat pump absorbs heat from the environment at a low temperature level and rejects heat at a high temperature level. The bigger the difference between the two temperature levels the more challenging is it to gain high energy efficiency with a basic cycle layout as found in most...... small capacity heat pump applications today. Many of the applicable refrigerants also reach their technical limits regarding low vapor pressure for very low source temperatures and high discharge temperatures for high sink temperatures. These issues are especially manifest for air-water heat pumps. Many...... alternative cycle setups and refrigerants are known to improve the energy efficiency of a vapor compression cycle and reduce discharge temperatures. However not all of them are feasible for small capacity heat pumps from a cost and complexity point of view. This paper presents a novel numerical approach...

  19. 1.8 K Refrigeration Units for the LHC: Performance Assessment of Pre-series Units

    CERN Document Server

    Claudet, S; Millet, F; Tavian, L; 20th International Cryogenic Engineering Conference (ICEC20)

    2005-01-01

    The cooling capacity below 2 K for the superconducting magnets of the Large Hadron Collider (LHC), at CERN, will be provided by eight refrigeration units of 2400 W at 1.8 K, each of them coupled to a 4.5 K refrigerator. The two selected vendors have proposed cycles based on centrifugal cold compressors combined with volumetric screw compressors with sub-atmospheric suction, as previously identified by CERN as “reference cycle”. The supply of the series units was linked to successful testing and acceptance of the pre-series temporarily installed in a dedicated test station. The global capacity, the performance of cold compressors and some process specificities have been thoroughly tested and will be presented.

  20. COP improvement of refrigerator/freezers, air-conditioners, and heat pumps using nonazeotropic refrigerant mixtures

    Science.gov (United States)

    Westra, Douglas G.

    1993-01-01

    With the February, 1992 announcement by President Bush to move the deadline for outlawing CFC (chloro-fluoro-carbon) refrigerants from the year 2000 to the year 1996, the refrigeration and air-conditioning industries have been accelerating their efforts to find alternative refrigerants. Many of the alternative refrigerants being evaluated require synthetic lubricants, are less efficient, and have toxicity problems. One option to developing new, alternative refrigerants is to combine existing non-CFC refrigerants to form a nonazeotropic mixture, with the concentration optimized for the given application so that system COP (Coefficient Of Performance) may be maintained or even improved. This paper will discuss the dilemma that industry is facing regarding CFC phase-out and the problems associated with CFC alternatives presently under development. A definition of nonazeotropic mixtures will be provided, and the characteristics and COP benefits of nonazeotropic refrigerant mixtures will be explained using thermodynamic principles. Limitations and disadvantages of nonazeotropic mixtures will be discussed, and example systems using such mixtures will be reviewed.

  1. Field measurements of supermarket refrigeration systems. Part I: Analysis of CO2 trans-critical refrigeration systems

    International Nuclear Information System (INIS)

    Sawalha, Samer; Karampour, Mazyar; Rogstam, Jörgen

    2015-01-01

    This study investigates the refrigeration performance of three CO 2 trans-critical solutions based on field measurements. The measurements are carried out in five supermarkets in Sweden. Using the field measurements, low and medium temperature level cooling capacities and COP's are calculated for ten-minute intervals, filtered and averaged to monthly values. The results indicate that the systems using trans-critical booster system with gas removal from the intermediate vessel have relatively the highest total COP. The reasons are higher evaporation temperatures, lower internal and external superheat and higher total efficiency of booster compressors. Another important factor is gas removal from the intermediate vessel which leads to higher COP of low temperature level. Comparing the older and newer installed systems, a trend in energy efficiency improvement has been seen. The study shows this improvement originates from both changes in the system design (e.g. two stage expansion) and components efficiency improvement (e.g. higher total efficiency of compressors - lower internal superheat and higher evaporation temperatures of cabinets). - Highlights: • Five Swedish supermarkets using three CO 2 refrigeration solutions are analyzed. • A trend of improvement in energy efficiency has been observed. • Parallel CO 2 system with indirect heat rejection offers the lowest energy efficiency. • CO 2 trans-critical booster with gas removal achieves up to 35% COP improvement

  2. Current fluctuations in quantum absorption refrigerators

    Science.gov (United States)

    Segal, Dvira

    2018-05-01

    Absorption refrigerators transfer thermal energy from a cold bath to a hot bath without input power by utilizing heat from an additional "work" reservoir. Particularly interesting is a three-level design for a quantum absorption refrigerator, which can be optimized to reach the maximal (Carnot) cooling efficiency. Previous studies of three-level chillers focused on the behavior of the averaged cooling current. Here, we go beyond that and study the full counting statistics of heat exchange in a three-level chiller model. We explain how to obtain the complete cumulant generating function of the refrigerator in a steady state, then derive a partial cumulant generating function, which yields closed-form expressions for both the averaged cooling current and its noise. Our analytical results and simulations are beneficial for the design of nanoscale engines and cooling systems far from equilibrium, with their performance optimized according to different criteria, efficiency, power, fluctuations, and dissipation.

  3. Model Based Control of Refrigeration Systems

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Sloth

    for automation of these procedures, that is to incorporate some "intelligence" in the control system, this project was started up. The main emphasis of this work has been on model based methods for system optimizing control in supermarket refrigeration systems. The idea of implementing a system optimizing...... control is to let an optimization procedure take over the task of operating the refrigeration system and thereby replace the role of the operator in the traditional control structure. In the context of refrigeration systems, the idea is to divide the optimizing control structure into two parts: A part...... optimizing the steady state operation "set-point optimizing control" and a part optimizing dynamic behaviour of the system "dynamical optimizing control". A novel approach for set-point optimization will be presented. The general idea is to use a prediction of the steady state, for computation of the cost...

  4. Basics of Low-temperature Refrigeration

    CERN Document Server

    Alekseev, A.

    2014-07-17

    This chapter gives an overview of the principles of low temperature refrigeration and the thermodynamics behind it. Basic cryogenic processes - Joule-Thomoson process, Brayton process as well as Claude process - are described and compared. A typical helium laboratory refrigerator based on Claude process is used as a typical example of a low-temperature refrigeration system. A description of the hardware components for helium liquefaction is an important part of this paper, because the design of the main hardware components (compressors, turbines, heat exchangers, pumps, adsorbers, etc.) provides the input for cost calculation, as well as enables to estimate the reliability of the plant and the maintenance expenses. All these numbers are necessary to calculate the economics of a low temperature application.

  5. Materials for Room Temperature Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Hansen, Britt Rosendahl

    Magnetic refrigeration is a cooling method, which holds the promise of being cleaner and more efficient than conventional vapor-compression cooling. Much research has been done during the last two decades on various magnetic materials for this purpose and today a number of materials are considered...... candidates as they fulfill many of the requirements for a magnetic refrigerant. However, no one material stands out and the field is still active with improving the known materials and in the search for a better one. Magnetic cooling is based on the magnetocaloric effect, which causes a magnetic material...... to change its temperature when a magnetic field is applied or removed. For room temperature cooling, one utilizes that the magnetocaloric effect peaks near magnetic phase transitions and so the materials of interest all have a critical temperature within the range of 250 – 310 K. A magnetic refrigerant...

  6. Basics of Low-temperature Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Alekseev, A [Linde AG, Munich (Germany)

    2014-07-01

    This chapter gives an overview of the principles of low temperature refrigeration and the thermodynamics behind it. Basic cryogenic processes - Joule-Thomoson process, Brayton process as well as Claude process - are described and compared. A typical helium laboratory refrigerator based on Claude process is used as a typical example of a low-temperature refrigeration system. A description of the hardware components for helium liquefaction is an important part of this paper, because the design of the main hardware components (compressors, turbines, heat exchangers, pumps, adsorbers, etc.) provides the input for cost calculation, as well as enables to estimate the reliability of the plant and the maintenance expenses. All these numbers are necessary to calculate the economics of a low temperature application.

  7. Performance characteristics of a quantum Diesel refrigeration cycle

    International Nuclear Information System (INIS)

    He Jizhou; Wang Hao; Liu Sanqiu

    2009-01-01

    The Diesel refrigeration cycle using an ideal quantum gas as the working substance is called quantum Diesel refrigeration cycle, which is different from Carnot, Ericsson, Brayton, Otto and Stirling refrigeration cycles. For ideal quantum gases, a corrected equation of state, which considers the quantum behavior of gas particles, is used instead of the classical one. The purpose of this paper is to investigate the effect of quantum gas as the working substance on the performance of a quantum Diesel refrigeration cycle. It is found that coefficients of performance of the cycle are not affected by the quantum degeneracy of the working substance, which is the same as that of the classical Diesel refrigeration cycle. However, the refrigeration load is different from those of the classical Diesel refrigeration cycle. Lastly, the influence of the quantum degeneracy on the performance characteristics of the quantum Diesel refrigeration cycle operated in different temperature regions is discussed

  8. Refrigerator Optimal Scheduling to Minimise the Cost of Operation

    Directory of Open Access Journals (Sweden)

    Bálint Roland

    2016-12-01

    Full Text Available The cost optimal scheduling of a household refrigerator is presented in this work. The fundamental approach is the model predictive control methodology applied to the piecewise affine model of the refrigerator.

  9. Retail Food Refrigeration and the Phaseout of HCFC-22

    Science.gov (United States)

    Provides information on the HCFC phaseout that is relevant to food retailers, including alternatives to the use of HCFC-22 in retail food refrigeration, other refrigerant regulations, and resources for more information.

  10. A Cold Cycle Dilution Refrigerator for Space Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The cold cycle dilution refrigerator is a continuous refrigerator capable of cooling to temperatures below 100 mK that makes use of a novel thermal magnetic pump....

  11. OPTIONS FOR REDUCING REFRIGERANT EMISSIONS FROM SUPERMARKET SYSTEMS

    Science.gov (United States)

    The report was prepared to assist personnel responsible for the design, construction, and maintenance of retail food refrigeration equipment in making knowledgeable decisions regarding the implementation of refrigerant-emissions-reducing practices and technologies. It characteriz...

  12. Simulation of absorption refrigeration system for automobile application

    Directory of Open Access Journals (Sweden)

    Ramanathan Anand

    2008-01-01

    Full Text Available An automotive air-conditioning system based on absorption refrigeration cycle has been simulated. This waste heat driven vapor absorption refrigeration system is one alternate to the currently used vapour compression refrigeration system for automotive air-conditioning. Performance analysis of vapor absorption refrigeration system has been done by developing a steady-state simulation model to find the limitation of the proposed system. The water-lithium bromide pair is used as a working mixture for its favorable thermodynamic and transport properties compared to the conventional refrigerants utilized in vapor compression refrigeration applications. The pump power required for the proposed vapor absorption refrigeration system was found lesser than the power required to operate the compressor used in the conventional vapor compression refrigeration system. A possible arrangement of the absorption system for automobile application is proposed.

  13. Performance of a Throttle Cycle Refrigerator with Nitrogen-Hydrocarbon and Argon-Hydrocarbon Mixtures

    Science.gov (United States)

    Venkatarathnam, G.; Senthil Kumar, P.; Srinivasa Murthy, S.

    2004-06-01

    Throttle cycle refrigerators are a class of vapor compression refrigerators that can provide refrigeration at cryogenic temperatures and operate with refrigerant mixtures. The performance of our prototype refrigerators with nitrogen-hydrocarbon, nitrogen-hydrocarbon-helium and argon-hydrocarbon refrigerant mixtures is presented in this paper.

  14. Toxicity Data to Determine Refrigerant Concentration Limits

    Energy Technology Data Exchange (ETDEWEB)

    Calm, James M.

    2000-09-30

    This report reviews toxicity data, identifies sources for them, and presents resulting exposure limits for refrigerants for consideration by qualified parties in developing safety guides, standards, codes, and regulations. It outlines a method to calculate an acute toxicity exposure limit (ATEL) and from it a recommended refrigerant concentration limit (RCL) for emergency exposures. The report focuses on acute toxicity with particular attention to lethality, cardiac sensitization, anesthetic and central nervous system effects, and other escape-impairing effects. It addresses R-11, R-12, R-22, R-23, R-113, R-114, R-116, R-123, R-124, R-125, R-134, R-134a, R-E134, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245ca, R-245fa, R-290, R-500, R-502, R-600a, R-717, and R-744. It summarizes additional data for R-14, R-115, R-170 (ethane), R-C318, R-600 (n-butane), and R-1270 (propylene) to enable calculation of limits for blends incorporating them. The report summarizes the data a nd related safety information, including classifications and flammability data. It also presents a series of tables with proposed ATEL and RCL concentrations-in dimensionless form and the latter also in both metric (SI) and inch-pound (IP) units of measure-for both the cited refrigerants and 66 zerotropic and azeotropic blends. They include common refrigerants, such as R-404A, R-407C, R-410A, and R-507A, as well as others in commercial or developmental status. Appendices provide profiles for the cited single-compound refrigerants and for R-500 and R-502 as well as narrative toxicity summaries for common refrigerants. The report includes an extensive set of references.

  15. Flow, stock, and impact assessment of refrigerants in the Japanese household air conditioner sector.

    Science.gov (United States)

    Xue, Mianqiang; Kojima, Naoya; Machimura, Takashi; Tokai, Akihiro

    2017-05-15

    Refrigerants provide society with great benefits while have the potential to cause adverse effects on the environment and human health. The present study estimated time-dependent flows and stocks and assessed the effects of refrigerants (R-22, R-410a, and R-32) in household air conditioners in Japan. It was found that stock of R-22 and R-410a peaked at 49,147t in 2000 and 55,994t in 2017, respectively. The largest flow of R-22 and R-410a to waste phase occurred at 3417t/yr. in 2005 and 4011t/yr. in 2023, respectively. The total global warming potential (GWP) due to refrigerant emissions increased from 3.6kt CO 2 eq. in 1952 to 6999kt CO 2 eq. in 2019, and then decreased to 5314kt CO 2 eq. in 2030. The ozone depletion potential (ODP) peaked at 141t CFC-11 eq. in 2002. When substituting R-410a for R-22, the ODP decreased 50% while the GDP increased 8%. When substituting R-32 for R-410a, there was no effect on the ODP while the GDP decreased 6%. The human health damage due to the global warming effect of refrigerant emission was much higher than that due to the ozone depleting effect. The refrigerant emission in use and waste management phases dominated the human health damage. The dynamic estimation not only allows us to evaluate the performance of past policies but also supports the future sustainable management associated with the health effects of refrigerants. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. THE STIRLING GAS REFRIGERATING MACHINE MECHANICAL DESIGN IMPROVING

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2016-06-01

    Full Text Available To improve the mechanical design of the piston Stirling gas refrigeration machine the structural optimization of rotary vane Stirling gas refrigeration machine is carried out. This paper presents the results of theoretical research. Analysis and prospects of rotary vane Stirling gas refrigeration machine for domestic and industrial refrigeration purpose are represented. The results of a patent search by mechanisms of transformation of rotary vane machines are discussed.

  17. THE STIRLING GAS REFRIGERATING MACHINE MECHANICAL DESIGN IMPROVING

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2016-02-01

    Full Text Available To improve the mechanical design of the piston Stirling gas refrigeration machine the structural optimization of rotary vane Stirling gas refrigeration machine is carried out. This paper presents the results of theoretical research. Analysis and prospects of rotary vane Stirling gas refrigeration machine for domestic and industrial refrigeration purpose are represented. The results of a patent search by mechanisms of transformation of rotary vane machines are discussed

  18. Boiling Heat Transfer to Halogenated Hydrocarbon Refrigerants

    Science.gov (United States)

    Yoshida, Suguru; Fujita, Yasunobu

    The current state of knowledge on heat transfer to boiling refrigerants (halogenated hydrocarbons) in a pool and flowing inside a horizontal tube is reviewed with an emphasis on information relevant to the design of refrigerant evaporators, and some recommendations are made for future research. The review covers two-phase flow pattern, heat transfer characteristics, correlation of heat transfer coefficient, influence of oil, heat transfer augmentation, boiling from tube-bundle, influence of return bend, burnout heat flux, film boiling, dryout and post-dryout heat transfer.

  19. Energy analysis of a supermarket refrigeration system

    DEFF Research Database (Denmark)

    Jensen, Jakob Munch; Jakobsen, Arne; Rasmussen, Bjarne D.

    1999-01-01

    From 1995 to 1998, an energy test method for supermarket refrigeration systems was developed in a project financed by the Danish Energy Agency. The purpose of the energy test method is to provide the means for evaluating the energy efficiency of these systems. The test method requires measurements...... of air temperatures and energy consumption to be carried out on the selected supermarket refrigeration system. In addition to the measurements required by the method, more measurements of individual energy consumptions have been carried in the case described in this paper. The purpose of the additional...

  20. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)