WorldWideScience

Sample records for reflectance spectrophotometry signals

  1. Surface composition of Mercury from reflectance spectrophotometry

    Science.gov (United States)

    Vilas, Faith

    1988-01-01

    The controversies surrounding the existing spectra of Mercury are discussed together with the various implications for interpretations of Mercury's surface composition. Special attention is given to the basic procedure used for reducing reflectance spectrophotometry data, the factors that must be accounted for in the reduction of these data, and the methodology for defining the portion of the surface contributing the greatest amount of light to an individual spectrum. The application of these methodologies to Mercury's spectra is presented.

  2. Effects of prolonged compression on the variations of haemoglobin oxygenation-assessment by spectral analysis of reflectance spectrophotometry signals

    International Nuclear Information System (INIS)

    Li, Zengyong; Tam, Eric W C; Mak, Arthur F T; Lau, Roy Y C

    2006-01-01

    The consequences of rhythmical flow motion for nutrition and the oxygen supply to tissue are largely unknown. In this study, the periodic variations of haemoglobin oxygenation in compressed and uncompressed skin were evaluated with a reflection spectrometer using an in vivo Sprague-Dawley rat model. Skin compression was induced over the trochanter area by a locally applied external pressure of 13.3 kPa (100 mmHg) via a specifically designed pneumatic indentor. A total of 19 rats were used in this study. The loading duration is 6 h per day for four consecutive days. Haemoglobin oxygenation variations were quantified using spectral analysis based on wavelets' transformation. The results found that in both compressed and uncompressed skin, periodic variations of the haemoglobin oxygenation were characterized by two frequencies in the range of 0.01-0.05 Hz and 0.15-0.4 Hz. These frequency ranges coincide with those of the frequency range of the endothelial-related metabolic and myogenic activities found in the flow motion respectively. Tissue compression following the above loading schedule induced a significant decrease in the spectral amplitudes of frequency interval 0.01-0.05 Hz during the pre-occlusion period on day 3 and day 4 as compared to that on day 1 (p 2 consumption rates of arteriolar walls. The modification of vessel wall oxygen consumption might substantially affect the available oxygen supply to the compressed tissue. This mechanism might be involved in the process leading to pressure ulcer formation

  3. Effects of prolonged compression on the variations of haemoglobin oxygenation-assessment by spectral analysis of reflectance spectrophotometry signals

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zengyong; Tam, Eric W C; Mak, Arthur F T; Lau, Roy Y C [Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong (China)

    2006-11-07

    The consequences of rhythmical flow motion for nutrition and the oxygen supply to tissue are largely unknown. In this study, the periodic variations of haemoglobin oxygenation in compressed and uncompressed skin were evaluated with a reflection spectrometer using an in vivo Sprague-Dawley rat model. Skin compression was induced over the trochanter area by a locally applied external pressure of 13.3 kPa (100 mmHg) via a specifically designed pneumatic indentor. A total of 19 rats were used in this study. The loading duration is 6 h per day for four consecutive days. Haemoglobin oxygenation variations were quantified using spectral analysis based on wavelets' transformation. The results found that in both compressed and uncompressed skin, periodic variations of the haemoglobin oxygenation were characterized by two frequencies in the range of 0.01-0.05 Hz and 0.15-0.4 Hz. These frequency ranges coincide with those of the frequency range of the endothelial-related metabolic and myogenic activities found in the flow motion respectively. Tissue compression following the above loading schedule induced a significant decrease in the spectral amplitudes of frequency interval 0.01-0.05 Hz during the pre-occlusion period on day 3 and day 4 as compared to that on day 1 (p < 0.05). In contrast, at a frequency range of 0.15-0.4 Hz, prolonged compression caused a significant increase in spectral amplitude during the pre-occlusion period in the compressed tissue on day 3 (p = 0.041) and day 4 (p = 0.024) compared to that in the uncompressed tissue on day 1. These suggested that the variations of the haemoglobin oxygenation were closely related to the endothelial-related metabolic and myogenic activities. Increased amplitude in the frequency interval 0.15-0.4 Hz indicated an increased workload of the vascular smooth muscle and could be attributed to the increase of O{sub 2} consumption rates of arteriolar walls. The modification of vessel wall oxygen consumption might

  4. Free radicals in irradiated unstabilized polypropylene, as seen by diffuse reflection absorption-spectrophotometry

    International Nuclear Information System (INIS)

    Zagorski, Z.P.; Rafalski, A.

    1998-01-01

    The introduction of UV-Vis absorption spectrophotometry to the study of radiation chemistry of polymers has opened the possibility to investigate even very opaque samples. The virgin powder polypropylene, as obtained from the industrial production line, shows after irradiation unstable products of radiolysis. Until now they were investigated mainly by EPR method. Optical absorption spectra (by diffuse reflection spectrophotometry) contribute to better identification and study of changes in time, temperature and diffusion of reactive gases. Studying the formation of stable compounds, which do not produce EPR signal, we are able to examine these species on the basis of their electronic spectra. The most important results concern the peroxides in irradiated polypropylene

  5. A comparison of hair colour measurement by digital image analysis with reflective spectrophotometry.

    Science.gov (United States)

    Vaughn, Michelle R; van Oorschot, Roland A H; Baindur-Hudson, Swati

    2009-01-10

    While reflective spectrophotometry is an established method for measuring macroscopic hair colour, it can be cumbersome to use on a large number of individuals and not all reflective spectrophotometry instruments are easily portable. This study investigates the use of digital photographs to measure hair colour and compares its use to reflective spectrophotometry. An understanding of the accuracy of colour determination by these methods is of relevance when undertaking specific investigations, such as those on the genetics of hair colour. Measurements of hair colour may also be of assistance in cases where a photograph is the only evidence of hair colour available (e.g. surveillance). Using the CIE L(*)a(*)b(*) colour space, the hair colour of 134 individuals of European ancestry was measured by both reflective spectrophotometry and by digital image analysis (in V++). A moderate correlation was found along all three colour axes, with Pearson correlation coefficients of 0.625, 0.593 and 0.513 for L(*), a(*) and b(*) respectively (p-values=0.000), with means being significantly overestimated by digital image analysis for all three colour components (by an average of 33.42, 3.38 and 8.00 for L(*), a(*) and b(*) respectively). When using digital image data to group individuals into clusters previously determined by reflective spectrophotometric analysis using a discriminant analysis, individuals were classified into the correct clusters 85.8% of the time when there were two clusters. The percentage of cases correctly classified decreases as the number of clusters increases. It is concluded that, although more convenient, hair colour measurement from digital images has limited use in situations requiring accurate and consistent measurements.

  6. Use of reflectance spectrophotometry to predict the response of port wine stains to pulsed dye laser.

    Science.gov (United States)

    Halachmi, Shlomit; Azaria, Ron; Inbar, Roy; Ad-El, Dean; Lapidoth, Moshe

    2014-01-01

    Reflectance spectroscopy can be used to quantitate subtle differences in color. We applied a portable reflectance spectrometer to determine its utility in the evaluation of pulsed dye laser treatment of port wine stains (PWS) and in prediction of clinical outcome, in a prospective study. Forty-eight patients with PWS underwent one to nine pulsed dye laser treatments. Patient age and skin color as well as PWS surface area, anatomic location, and color were recorded. Pretreatment spectrophotometric measurements were performed. The subjective clinical results of treatment and the quantitative spectrophotometry results were evaluated by two independent teams, and the findings were correlated. The impact of the clinical characteristics on the response to treatment was assessed as well. Patients with excellent to good clinical results of laser treatments had pretreatment spectrophotometric measurements which differed by more than 10%, whereas patients with fair to poor results had spectrophotometric measurements with a difference of of less than 10%. The correlation between the spectrophotometric results and the clinical outcome was 73% (p Spectrophotometry has a higher correlation with clinical outcome and a better predictive value than other nonmeasurable, nonquantitative, dependent variables.

  7. Colour characteristics of the blunt egg pole: cues for recognition of parasitic eggs as revealed by reflectance spectrophotometry

    Czech Academy of Sciences Publication Activity Database

    Polačiková, Lenka; Honza, Marcel; Procházka, Petr; Topercer, J.; Stokke, B. G.

    2007-01-01

    Roč. 74, č. 3 (2007), s. 419-427 ISSN 0003-3472 R&D Projects: GA ČR(CZ) GD524/05/H536; GA AV ČR IAA600930605; GA MŠk LC06073 Institutional research plan: CEZ:AV0Z60930519 Keywords : blackcap * brood parasitism * recognition cues * reflectance spectrophotometry * rejection behaviour Subject RIV: EH - Ecology, Behaviour Impact factor: 2.752, year: 2007

  8. Use of reflectance spectrophotometry and colorimetry in a general linear model for the determination of the age of bruises.

    Science.gov (United States)

    Hughes, Vanessa K; Langlois, Neil E I

    2010-12-01

    Bruises can have medicolegal significance such that the age of a bruise may be an important issue. This study sought to determine if colorimetry or reflectance spectrophotometry could be employed to objectively estimate the age of bruises. Based on a previously described method, reflectance spectrophotometric scans were obtained from bruises using a Cary 100 Bio spectrophotometer fitted with a fibre-optic reflectance probe. Measurements were taken from the bruise and a control area. Software was used to calculate the first derivative at 490 and 480 nm; the proportion of oxygenated hemoglobin was calculated using an isobestic point method and a software application converted the scan data into colorimetry data. In addition, data on factors that might be associated with the determination of the age of a bruise: subject age, subject sex, degree of trauma, bruise size, skin color, body build, and depth of bruise were recorded. From 147 subjects, 233 reflectance spectrophotometry scans were obtained for analysis. The age of the bruises ranged from 0.5 to 231.5 h. A General Linear Model analysis method was used. This revealed that colorimetric measurement of the yellowness of a bruise accounted for 13% of the bruise age. By incorporation of the other recorded data (as above), yellowness could predict up to 32% of the age of a bruise-implying that 68% of the variation was dependent on other factors. However, critical appraisal of the model revealed that the colorimetry method of determining the age of a bruise was affected by skin tone and required a measure of the proportion of oxygenated hemoglobin, which is obtained by spectrophotometric methods. Using spectrophotometry, the first derivative at 490 nm alone accounted for 18% of the bruise age estimate. When additional factors (subject sex, bruise depth and oxygenation of hemoglobin) were included in the General Linear Model this increased to 31%-implying that 69% of the variation was dependent on other factors. This

  9. Seasonal Skin Colour Changes in a Sample Teenage Population Measured by Reflection Spectrophotometry

    Science.gov (United States)

    Stringer, M. R.; Cruse-Sawyer, J. E.

    2007-01-01

    As part of a classroom-based research project, reflectance spectra from the skin of a group of teenage school students were recorded over a four-month period, from early spring to mid-summer. The relative changes in skin colour during the course of the study were quantified by integrating over the full wavelength range of the normalized…

  10. Acquiring Sediment and Element Compositional Changes Based on a Diffuse Reflectance Spectrophotometry Technology from Cores Offshore Southwestern Taiwan

    Science.gov (United States)

    Pan, H. J.; Chen, M. T.

    2014-12-01

    Heavy summer monsoon rainfall along with typhoon-induced extreme precipitation cause frequent geological hazards that often threaten the human's safety and property in Taiwan. These geological hazards can be triggered by both natural factors, and/or have become deteriorated by perturbations from more and more human activities ever since few thousand years ago. However, due to the limit of instrumental records for observing long-term environmental changes in Taiwan, few evidence exist for distinguishing the human-induced impacts from natural climate change. Here we report a study on a high quality marine sediment core (MD103264) which were retrieved from the high sedimentation rate area from offshore southwestern Taiwan and present evidence for the long-term climate and possibly human-induced environmental changes since the last glacial. We are using the VIS-NIR Diffuse Reflectance Spectrophotometry (DRS) methods to study the cores. Interpreting the VIS-NIR reflectance spectra through the VARIMAX-rotation, principle component analysis (VPCA) helps conducting rapid and inexpensive measurements for acquiring high-resolution biogenic component, clay, and iron oxide mineral compositional data from the cores. We are also using X-Ray Fluorescence (XRF) analysis, which is also useful in determining the element compositional changes in the core. Our studies aim toward understanding the sediment and element compositional changes that reflect the patterns of changes in precipitation and soil erosion on land since the last glacial to the Holocene, during which the human activities (deforestation, agriculture, and land uses change) may have increased drastically. We will report and interpret the preliminary results of the optical analyses of the core.

  11. Variable reflectivity signal mirrors and signal response measurements

    International Nuclear Information System (INIS)

    Vine, Glenn de; Shaddock, Daniel A; McClelland, David E

    2002-01-01

    Future gravitational wave detectors will include some form of signal mirror in order to alter the signal response of the device. We introduce interferometer configurations which utilize a variable reflectivity signal mirror allowing a tunable peak frequency and variable signal bandwidth. A detector configured with a Fabry-Perot cavity as the signal mirror is compared theoretically with one using a Michelson interferometer for a signal mirror. A system for the measurement of the interferometer signal responses is introduced. This technique is applied to a power-recycled Michelson interferometer with resonant sideband extraction. We present broadband measurements of the benchtop prototype's signal response for a range of signal cavity detunings. This technique is also applicable to most other gravitational wave detector configurations

  12. Variable reflectivity signal mirrors and signal response measurements

    CERN Document Server

    Vine, G D; McClelland, D E

    2002-01-01

    Future gravitational wave detectors will include some form of signal mirror in order to alter the signal response of the device. We introduce interferometer configurations which utilize a variable reflectivity signal mirror allowing a tunable peak frequency and variable signal bandwidth. A detector configured with a Fabry-Perot cavity as the signal mirror is compared theoretically with one using a Michelson interferometer for a signal mirror. A system for the measurement of the interferometer signal responses is introduced. This technique is applied to a power-recycled Michelson interferometer with resonant sideband extraction. We present broadband measurements of the benchtop prototype's signal response for a range of signal cavity detunings. This technique is also applicable to most other gravitational wave detector configurations.

  13. Spectrophotometry of white dwarfs as observed at high signal-to-noise ratio. II

    International Nuclear Information System (INIS)

    Greenstein, J.L.; Liebert, J.W.

    1990-01-01

    CCD spectrophotometry is presented of 140 white dwarfs at high SNR and is analyzed in detail. Energy distributions at 14,000 A are given at bandpasses from 3571 to 8300 A, and equivalent widths of lines of H, He I, metals, and atomic and molecular carbon are given as functions of color for DB, DQ, DZ, and DA stars. New forbidden H I transitions at 6068 A and 6632 A are found in at least the two hottest DB stars, new metallic features are found in cooler DZ stars, and the presence of Ca I in vMa 2 is confirmed. The spectrum of the hot DQAB star G227 - 5 and the pressure-shifted carbon bands seen in 0038-226 are discussed in detail. Comparison of the optical energy distribution of the latter with published IR fluxes shows that the 1-2 micron region is strongly depressed, with extensive blanketing. Equivalent widths, central depths, and width parameters are presented for H-alpha in 73 DA stars in the sample, and their dependences on color are studied. 64 refs

  14. Modification of the Fitzpatrick system of skin phototype classification for the Indian population, and its correlation with narrowband diffuse reflectance spectrophotometry.

    Science.gov (United States)

    Sharma, V K; Gupta, V; Jangid, B L; Pathak, M

    2018-04-01

    The Fitzpatrick classification for skin phototyping is widely used, but its usefulness in dark-skinned populations has been questioned by some researchers. Recently, skin colour measurement has been proposed for phototyping skin colour objectively. To modify the Fitzpatrick system of skin phototyping for the Indian population and to study its correlation with skin colour using narrowband diffuse reflectance spectrophotometry METHODS: Answer choices for three items (eye colour, hair colour, colour of unexposed skin) out of 10 in the original Fitzpatrick questionnaire were modified, followed by self-administration of the original and the modified Fitzpatrick questionnaire by 70 healthy Indian volunteers. Skin colour (melanin and erythema indices) was measured from two photoexposed and two photoprotected sites using a narrowband reflectance spectrophotometer. The mean ± SD scores for the original and modified Fitzpatrick questionnaires were 25.40 ± 4.49 and 23.89 ± 4.82, respectively (r = 0.97, P Spectrophotometry can be a useful objective tool for skin phototyping. © 2018 British Association of Dermatologists.

  15. Objective evaluation by reflectance spectrophotometry can be of clinical value for the verification of blanching/non blanching erythema in the sacral area.

    Science.gov (United States)

    Sterner, Eila; Fossum, Bjöörn; Berg, Elisabeth; Lindholm, Christina; Stark, André

    2014-08-01

    Early detection of non blanching erythema (pressure ulcer category I) is necessary to prevent any further skin damage. An objective method to discriminate between blanching/non blanching erythema is presently not available. The purpose of this investigation was to explore if a non invasive objective method could differentiate between blanching/non blanching erythema in the sacral area of patients undergoing hip fracture surgery. Seventy-eight patients were included. The sacral area of all patients was assessed using (i) conventional finger-press test and (ii) digital reading of the erythema index assessed with reflectance spectrophotometry. The patients were examined at admission and during 5 days postsurgery. Reflectance spectrophotometry measurements proved able to discriminate between blanching/non blanching erythema. The reliability, quantified by the intra-class correlation coefficient, was excellent between repeated measurements over the measurement period, varying between 0·82 and 0·96, and a significant change was recorded in the areas from day 1 to day 5 (P < 0·0001). The value from the reference point did not show any significant changes over the same period (P = 0·32). An objective method proven to identify early pressure damage to tissue can be a valuable tool in clinical practice. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  16. Solid-phase spectrophotometry

    International Nuclear Information System (INIS)

    Brykina, G.D.; Marchenko, D.Yu.; Shpigun, O.A.

    1995-01-01

    Solid-phase spectrophotometry (SPS), which is based on the direct measurement of light absorption of an ion exchanger containing a substance of interest, was reviewed. Since 1976, it has been known that aborbance of an ion exchanger is directly proportional to the concentration of a particular ion in solution. A similar dependence can also be followed for other sorbents, as well as for foams, membranes, films, etc., which do not exhibit ion exchange properties. One can use absorption, diffuse reflection, and luminescence spectra parameters as an analytical signal. Thus, SPS of ion exchangers is among the analytical techniques that combine the sorption concentration and surface determination of the substance of interest. This review summarizes the advancements in SPS over the last six years and demonstrates the prospects for its development. Special attention is paid to experimental methods for measuring solid-phase absorption and to the basic procedures of sample preparation, including new ones. These two facets are of great importance for obtaining precise results and extending the capabilities of SPS

  17. A methodological approach to study the stability of selected watercolours for painting reintegration, through reflectance spectrophotometry, Fourier transform infrared spectroscopy and hyperspectral imaging

    Science.gov (United States)

    Pelosi, Claudia; Capobianco, Giuseppe; Agresti, Giorgia; Bonifazi, Giuseppe; Morresi, Fabio; Rossi, Sara; Santamaria, Ulderico; Serranti, Silvia

    2018-06-01

    The aim of this work is to investigate the stability to simulated solar radiation of some paintings samples through a new methodological approach adopting non-invasive spectroscopic techniques. In particular, commercial watercolours and iron oxide based pigments were used, these last ones being prepared for the experimental by gum Arabic in order to propose a possible substitute for traditional reintegration materials. Reflectance spectrophotometry in the visible range and Hyperspectral Imaging in the short wave infrared were chosen as non-invasive techniques for evaluation the stability to irradiation of the chosen pigments. These were studied before and after artificial ageing procedure performed in Solar Box chamber under controlled conditions. Data were treated and elaborated in order to evaluate the sensitivity of the chosen techniques in identifying the variations on paint layers, induced by photo-degradation, before they could be observed by eye. Furthermore a supervised classification method for monitoring the painted surface changes adopting a multivariate approach was successfully applied.

  18. Signal processing issues in reflection tomography

    Science.gov (United States)

    Cadalli, Nail

    2001-12-01

    This dissertation focuses on signal modeling and processing issues of the following problems in reflection tomography: synthetic aperture radar (SAR) imaging of a runway and surroundings from an aircraft approaching for landing, acoustic imaging of objects buried in soil, and lidar imaging of underwater objects. The highly squinted geometry of runway imaging necessitates the incorporation of wavefront curvature into the signal model. We investigate the feasibility of using the wavenumber-domain (ω - k) SAR inversion algorithm, which models the actual curvature of the wavefront, for runway imaging. We demonstrate the aberrations that the algorithm can produce when the squint angle is close to 90° and show that high-quality reconstruction is still possible provided that the interpolation is performed accurately enough, which can be achieved by increasing the temporal sampling rate. We compare the performance with that of a more general inversion method (GIM) that solves the measurement equation directly. The performances of both methods are comparable in the noise- free case. Being inherently robust to noise, GIM produces superior results in the noisy case. We also present a solution to the left-right ambiguity of runway imaging using interferometric processing. In imaging of objects buried in soil, we pursue an acoustic approach primarily for detection and imaging of cultural artifacts. We have developed a mathematical model and associated computer software in order to simulate the signals acquired by the actual experimental system, and a bistatic SAR-type algorithm for reconstruction. In the reconstructions from simulated data, objects were detectable, but near-field objects suffered from shifts and smears. To account for wavefront curvature, we formulated processing of the simulated data using the 3-D version of the monostatic ω - k algorithm. In lidar imaging of underwater objects, we formulate the problem as a 3-D tomographic reconstruction problem. We have

  19. Signal-enhancement reflective pulse oximeter with Fresnel lens

    Science.gov (United States)

    Chung, Shuang-Chao; Sun, Ching-Cherng

    2016-09-01

    In this paper, a new reflective pulse oximeter is proposed and demonstrated with implanting a Fresnel lens, which enhances the reflected signal. An optical simulation model incorporated with human skin characteristics is presented to evaluate the capability of the Fresnel lens. In addition, the distance between the light emitting diode and the photodiode is optimized. Compared with the other reflective oximeters, the reflected signal light detected by the photodiode is enhanced to more than 140%.

  20. Information content in reflected global navigation satellite system signals

    DEFF Research Database (Denmark)

    Høeg, Per; Carlstrom, Anders

    2011-01-01

    The direct signals from satellites in global satellite navigation satellites systems (GNSS) as, GPS, GLONASS and GALILEO, constitute the primary source for positioning, navigation and timing from space. But also the reflected GNSS signals contain an important information content of signal travel...

  1. Information content in reflected signals during GPS Radio Occultation observations

    Science.gov (United States)

    Aparicio, Josep M.; Cardellach, Estel; Rodríguez, Hilda

    2018-04-01

    The possibility of extracting useful information about the state of the lower troposphere from the surface reflections that are often detected during GPS radio occultations (GPSRO) is explored. The clarity of the reflection is quantified, and can be related to properties of the surface and the low troposphere. The reflected signal is often clear enough to show good phase coherence, and can be tracked and processed as an extension of direct non-reflected GPSRO atmospheric profiles. A profile of bending angle vs. impact parameter can be obtained for these reflected signals, characterized by impact parameters that are below the apparent horizon, and that is a continuation at low altitude of the standard non-reflected bending angle profile. If there were no reflection, these would correspond to tangent altitudes below the local surface, and in particular below the local mean sea level. A forward operator is presented, for the evaluation of the bending angle of reflected GPSRO signals, given atmospheric properties as described by a numerical weather prediction system. The operator is an extension, at lower impact parameters, of standard bending angle operators, and reproduces both the direct and reflected sections of the measured profile. It can be applied to the assimilation of the reflected section of the profile as supplementary data to the direct section. Although the principle is also applicable over land, this paper is focused on ocean cases, where the topographic height of the reflecting surface, the sea level, is better known a priori.

  2. Analytical application of derivative spectrophotometry

    Directory of Open Access Journals (Sweden)

    VIOLETA M. STEFANOVIC

    2000-07-01

    Full Text Available 1. Introduction 2. Basic characteristics of derivative spectrophotometry 2.1. Increase of spectra resolution 2.2. Elimination of the influence of baseline shift and matrix interferences 2.3. Enhancement of the detectability of minor spectral features 2.4. Precise determination of the positions of absorption maxima 2.5. Signal-to-noise ratio (SNR 2.6. Quantitative analysis 3. Analytical applications 3.1. Inorganic analysis 3.2. Organic and pharmaceutical analysis 3.3. Analysis of food and water 3.4. Application of derivative spectrophotometry for the determination of equilibrium constants

  3. Enamel Mineral Content Changes After Bleaching With High and Low Hydrogen Peroxide Concentrations: Colorimetric Spectrophotometry and Total Reflection X-ray Fluorescence Analyses.

    Science.gov (United States)

    Pinto, Avd; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Pérez, C A; Martinez, E F; Flório, F M; Basting, R T

    The purpose of this study was to evaluate the calcium (Ca) and phosphorous (P) content in enamel bleached with high and low concentrations of hydrogen peroxide (HP) using Total Reflection X-Ray Fluorescence (TXRF) and colorimetric spectrophotometry (SPEC). Forty-eight sound human third molars were used. Their roots were embedded in polystyrene resin and immersed for seven days in an artificial saliva solution. Then they were distributed into six groups to receive the bleaching treatments. The agents of high HP concentration (for in-office use) evaluated were Whiteness HP Maxx/FGM (35% HP), Whiteness HP Blue/FGM (35% HP, 2% calcium gluconate), Pola Office+/SDI (37.5% HP, 5% potassium nitrate), and Opalescence Boost/Ultradent (38% HP, 1.1% ion fluoride, 3% potassium nitrate); these agents were applied to enamel in three sessions. The agents of low HP concentration (for home use) evaluated were Pola Day/SDI (9.5% HP) and White Class 10%/FGM (10% HP, potassium nitrate, calcium, fluoride), and these agents were applied for 14 days. Enamel microbiopsies were evaluated by TXRF and SPEC analysis before the bleaching treatment (baseline), during the treatment, and 14 days after the end of the treatment. For TXRF, the Kruskal-Wallis test showed that Ca and P were not influenced by agent (p>0.05). For SPEC, Pola Office+, Opalescence Boost, Pola Day, and White Class 10% caused a decrease of Ca over time; there was a significant decrease of P over time to Pola Office+ and White Class 10%. The Spearman test showed no correlation between the Ca (p=0.987; r 2 =-0.020) and P (p=0.728, r 2 =0.038) obtained by SPEC and TXRF. For TXRF and SPEC, changes in Ca and P during bleaching occurred independently of the HP concentration used.

  4. Meteorological information in GPS-RO reflected signals

    Directory of Open Access Journals (Sweden)

    K. Boniface

    2011-07-01

    Full Text Available Vertical profiles of the atmosphere can be obtained globally with the radio-occultation technique. However, the lowest layers of the atmosphere are less accurately extracted. A good description of these layers is important for the good performance of Numerical Weather Prediction (NWP systems, and an improvement of the observational data available for the low troposphere would thus be of great interest for data assimilation. We outline here how supplemental meteorological information close to the surface can be extracted whenever reflected signals are available. We separate the reflected signal through a radioholographic filter, and we interpret it with a ray tracing procedure, analyzing the trajectories of the electromagnetic waves over a 3-D field of refractive index. A perturbation approach is then used to perform an inversion, identifying the relevant contribution of the lowest layers of the atmosphere to the properties of the reflected signal, and extracting some supplemental information to the solution of the inversion of the direct propagation signals. It is found that there is a significant amount of useful information in the reflected signal, which is sufficient to extract a stand-alone profile of the low atmosphere, with a precision of approximately 0.1 %. The methodology is applied to one reflection case.

  5. Atomic-fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Bakhturova, N.F.; Yudelevich, I.G.

    1975-01-01

    Atomic-fluorescence spectrophotometry, a comparatively new method for the analysis of trace quantities, has developed rapidly in the past ten years. Theoretical and experimental studies by many workers have shown that atomic-fluorescence spectrophotometry (AFS) is capable of achieving a better limit than atomic absorption for a large number of elements. The present review examines briefly the principles of atomic-fluorescence spectrophotometry and the types of fluorescent transition. The excitation sources, flame and nonflame atomizers, used in AFS are described. The limits of detection achieved up to the present, using flame and nonflame methods of atomization are given

  6. Spectrophotometry of RR Telescopii

    International Nuclear Information System (INIS)

    Walker, A.R.

    1977-01-01

    The strongest emission lines in the nova-like variable RR Telescopii were measured during late 1974 using a spectrum scanner. The wavelength range 3350 to 7700 A was scanned with a resolution of 50 A. The results are compared with published spectrophotometry covering the period 1961 to 72, with the conclusion that few changes have taken place in the last 6 yr. No evidence was found that suggested the existence of a cool star, nor was there any indication of night-to-night changes in the emission line intensities. The spectrophotometry of the past 15 yr is consistent with an expanding shell, the emission from this shell being caused by high-energy radiation from an underlying star. (author)

  7. Reflectance spectrophotometry (about 0.5-1.0 micron) of oute-belt asteroids - Implications for primitive, organic solar system material

    Science.gov (United States)

    Vilas, F.; Smith, B. A.

    1985-01-01

    The surface compositions of outer-belt asteroids were used to obtain information about the origin of these asteroids. High-resolution CCD reflectance spectra of 21 asteroids, primarily P class, were examined for compositional information. Distinct slope changes are observed that suggest that these asteroids are the remnants of a compositional gradation of planetesimals in the outer solar system, which were retained selectively in location when other material was ejected from the solar system. Other data suggest that this gradation could extend through the orbits of Uranus and Neptune.

  8. Atomic absorption spectrophotometry in perspective

    International Nuclear Information System (INIS)

    Soffiantini, V.

    1981-01-01

    Atomic absorption spectrophotometry is essentially an analytical technique used for quantitative trace metal analysis in a variety of materials. The speed and specificity of the technique is its greatest advantage over other analytical techniques. What atomic absorption spectrophotometry can and cannot do and its advantages and disadvantages are discussed, a summary of operating instructions are given, as well as a summary of analytical interferences. The applications of atomic absorption spectrophotometry are also shortly discussed

  9. Automation of plutonium spectrophotometry

    International Nuclear Information System (INIS)

    Perez, J.J.; Boisde, G.; Goujon de Beauvivier, M.; Chevalier, G.; Isaac, M.

    1980-01-01

    Instrumentation was designed and constructed for automatic control of plutonium by molecular absorption spectrophotometry, on behalf of the reprocessing facilities, to meet two objectives: on-line measurement, of the valency state of plutonium, on by-pass, with the measured concentration covering the process concentration range up to a few mg.l -1 ; laboratory measurement of plutonium adjusted to valency VI, with operation carried out using a preparative system meeting the required containment specifications. For this two objectives, the photometer, optical cell connections are made by optical fibers resistant to β, γ radiation. Except this characteristic the devices are different according to the quality required for result [fr

  10. Quantitative analysis of active compounds in pharmaceutical preparations by use of attenuated total-reflection Fourier transform mid-infrared spectrophotometry and the internal standard method.

    Science.gov (United States)

    Sastre Toraño, J; van Hattum, S H

    2001-10-01

    A new method is presented for the quantitative analysis of compounds in pharmaceutical preparations Fourier transform (FT) mid-infrared (MIR) spectroscopy with an attenuated total reflection (ATR) module. Reduction of the quantity of overlapping absorption bands, by interaction of the compound of interest with an appropriate solvent, and the employment of an internal standard (IS), makes MIR suitable for quantitative analysis. Vigabatrin, as active compound in vigabatrin 100-mg capsules, was used as a model compound for the development of the method. Vigabatrin was extracted from the capsule content with water after addition of a sodium thiosulfate IS solution. The extract was concentrated by volume reduction and applied to the FTMIR-ATR module. Concentrations of unknown samples were calculated from the ratio of the vigabatrin band area (1321-1610 cm(-1)) and the IS band area (883-1215 cm(-1)) using a calibration standard. The ratio of the area of the vigabatrin peak to that of the IS was linear with the concentration in the range of interest (90-110 mg, in twofold; n=2). The accuracy of the method in this range was 99.7-100.5% (n=5) with a variability of 0.4-1.3% (n=5). The comparison of the presented method with an HPLC assay showed similar results; the analysis of five vigabatrin 100-mg capsules resulted in a mean concentration of 102 mg with a variation of 2% with both methods.

  11. Simulation of GNSS reflected signals and estimation of position accuracy in GNSS-challenged environment

    DEFF Research Database (Denmark)

    Jakobsen, Jakob; Jensen, Anna B. O.; Nielsen, Allan Aasbjerg

    2015-01-01

    non-line-of-sight satellites. The signal reflections are implemented using the extended geometric path length of the signal path caused by reflections from the surrounding buildings. Based on real GPS satellite positions, simulated Galileo satellite positions, models of atmospheric effect...... on the satellite signals, designs of representative environments e.g. urban and rural scenarios, and a method to simulate reflection of satellite signals within the environment we are able to estimate the position accuracy given several prerequisites as described in the paper. The result is a modelling...... of the signal path from satellite to receiver, the satellite availability, the extended pseudoranges caused by signal reflection, and an estimate of the position accuracy based on a least squares adjustment of the extended pseudoranges. The paper describes the models and algorithms used and a verification test...

  12. Using neurophysiological signals that reflect cognitive or affective state

    NARCIS (Netherlands)

    Brouwer, Anne-Marie; Zander, Thorsten O.; van Erp, Johannes Bernardus Fransiscus

    2015-01-01

    What can we learn from spontaneously occurring brain and other physiological signals about an individual’s cognitive and affective state and how can we make use of this information? One line of research that is actively involved with this question is Passive Brain-Computer-Interfaces (BCI). To date

  13. Separation and reconstruction of high pressure water-jet reflective sound signal based on ICA

    Science.gov (United States)

    Yang, Hongtao; Sun, Yuling; Li, Meng; Zhang, Dongsu; Wu, Tianfeng

    2011-12-01

    The impact of high pressure water-jet on the different materials target will produce different reflective mixed sound. In order to reconstruct the reflective sound signals distribution on the linear detecting line accurately and to separate the environment noise effectively, the mixed sound signals acquired by linear mike array were processed by ICA. The basic principle of ICA and algorithm of FASTICA were described in detail. The emulation experiment was designed. The environment noise signal was simulated by using band-limited white noise and the reflective sound signal was simulated by using pulse signal. The reflective sound signal attenuation produced by the different distance transmission was simulated by weighting the sound signal with different contingencies. The mixed sound signals acquired by linear mike array were synthesized by using the above simulated signals and were whitened and separated by ICA. The final results verified that the environment noise separation and the reconstruction of the detecting-line sound distribution can be realized effectively.

  14. Derivative spectrophotometry of cobalt alloys

    International Nuclear Information System (INIS)

    Spitsyn, P.K.

    1985-01-01

    The method of derivative spectrophotometry is briefly described, and derivative absorption spectra are presented for samarium, cobalt, and commercial Sm-Co alloys. It is shown that the use of derivative spectrophotometry not only improves the accuracy and selectivity of element determinations but also simplifies the analysis of alloys. Results of a statistical evaluation of the metrological characteristics of the analytical procedure described here are presented. 8 references

  15. A METHOD USING GNSS LH-REFLECTED SIGNALS FOR SOIL ROUGHNESS ESTIMATION

    Directory of Open Access Journals (Sweden)

    Y. Jia

    2018-04-01

    Full Text Available Global Navigation Satellite System Reflectometry (GNSS-R is based on the concept of receiving GPS signals reflected by the ground using a passive receiver. The receiver can be on the ground or installed on a small aircraft or UAV and collects the electromagnetic field scattered from the surface of the Earth. The received signals are then analyzed to determine the characteristics of the surface. Many research has been reported showing the capability of the GNSS-R technique. However, the roughness of the surface impacts the phase and amplitude of the received signals, which is still a worthwhile study. This paper presented a method can be used by GNSS-R to estimate the surface roughness. First, the data was calculated in the specular reflection with the assumption of a flat surface with different permittivity. Since the power reflectivity can be evaluated as the ratio of left-hand (LH reflected signal to the direct right-hand (RH signal. Then a semi-empirical roughness model was applied to the data for testing. The results showed the method can distinguish the water and the soil surface. The sensitivity of the parameters was also analyzed. It indicates this method for soil roughness estimation can be used by GNSS-R LH reflected signals. In the next step, several experiments need to be done for improving the model and exploring the way of the estimation.

  16. a Method Using Gnss Lh-Reflected Signals for Soil Roughness Estimation

    Science.gov (United States)

    Jia, Y.; Li, W.; Chen, Y.; Lv, H.; Pei, Y.

    2018-04-01

    Global Navigation Satellite System Reflectometry (GNSS-R) is based on the concept of receiving GPS signals reflected by the ground using a passive receiver. The receiver can be on the ground or installed on a small aircraft or UAV and collects the electromagnetic field scattered from the surface of the Earth. The received signals are then analyzed to determine the characteristics of the surface. Many research has been reported showing the capability of the GNSS-R technique. However, the roughness of the surface impacts the phase and amplitude of the received signals, which is still a worthwhile study. This paper presented a method can be used by GNSS-R to estimate the surface roughness. First, the data was calculated in the specular reflection with the assumption of a flat surface with different permittivity. Since the power reflectivity can be evaluated as the ratio of left-hand (LH) reflected signal to the direct right-hand (RH) signal. Then a semi-empirical roughness model was applied to the data for testing. The results showed the method can distinguish the water and the soil surface. The sensitivity of the parameters was also analyzed. It indicates this method for soil roughness estimation can be used by GNSS-R LH reflected signals. In the next step, several experiments need to be done for improving the model and exploring the way of the estimation.

  17. Tunable Diode Laser Heterodyne Spectrophotometry of Ozone

    Science.gov (United States)

    Fogal, P. F.; McElroy, C. T.; Goldman, A.; Murcray, D. G.

    1988-01-01

    Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (less than 0.0005/ cm) solar spectra in the 9.6 micron ozone band. Observations have shown that a signal-to-noise ratio of 95 : 1 (35% of theoretical) for an integration time of 1/8 second can be achieved at a resolution of 0.0005 wavenumbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that. measured at the nearby National Oceanographic and Atmospheric Administration (NOAA) ozone monitoring facility in Boulder, Colorado.

  18. Experimental demonstration of a variable reflectivity signal recycled Michelson interferometer for gravitational wave detection

    International Nuclear Information System (INIS)

    De Vine, G.; Shaddock, D.; McClelland, D.

    2002-01-01

    Full text: One technique of improving the sensitivity of interferometric gravitational wave detectors is to implement a signal mirror. This involves placing a mirror at the output of the Michelson interferometer. The gravitational wave signal is then 'recycled' back into the interferometer where it can coherently add with the gravitational wave signal still being produced. The frequency of the improved sensitivity is dependent on the position of the signal mirror, while the peak height and bandwidth are dependent on the reflectivity of the signal mirror. This is because the signal mirror forms a cavity with the Michelson interferometer and this cavity has a resonant frequency dependent on its length and a bandwidth dependent on its finesse, which are a function of signal mirror position and reflectivity, respectively. Due to the varying and/or unknown nature of the gravitational wave frequencies and wave-forms, it is desirable to be able to control both the peak frequency and bandwidth of the detector. The peak frequency can be easily adjusted by altering the signal mirror position. The bandwidth, however, is fixed with the signal mirror reflectivity. In a long base-line gravitational wave detector it is impractical to swap the signal mirror with one of different reflectivity for a number of reasons, for example, the detector's high vacuum would have to be broken, realignment performed and locking re-acquired. This is addressed by the proposal of two different forms of variable reflectivity signal mirror (VRSM): a Fabry-Perot cavity and a Michelson interferometer. These are analysed and the reasons for choosing to investigate the Michelson VRSM are given. The reasons include the potential for easier control and the smooth variation in reflectivity with arm length difference. The experiment is discussed and the results of the first demonstration of variable reflectivity signal recycling are presented in the form of frequency responses obtained by injecting a second

  19. Boundary Layer Ducting of Low-elevation GNSS Ocean Reflected Signals

    DEFF Research Database (Denmark)

    Høeg, Per; von Benzon, Hans-Henrik; Durgonics, Tibor

    for the data retrievals and the precision and the accuracy, are of interest for assessing the observational data content.Simulations of the low-elevation ocean reflected GNSS signal reveal a ducting of the signalwhen applying a model of the boundary layer. This effect is presented during varying conditions...... of the sea surface roughness, ocean wind and temperature, density and gradient of the water vapor profile in the boundary layer.The model for the sea surface roughness impedance, wind speed, and rms ocean wave-heightshow a stronger signal damping for a smoother ocean surfaces (sea state 0) compared...... to a rough sea (sea state 4). While the real part of the signal shows the reverse effect. At the same time the reflection zone enhances for rough sea states. Simulations, including a standard atmosphere and a boundary layer, give a significant ducting of the received signal, leading to a much larger...

  20. Spectrophotometry of nova Cygni 1975

    International Nuclear Information System (INIS)

    Panek, R.J.

    1977-01-01

    Low-resolution spectrophotometry of nova Cygni 1975 is presented for eight nights in September 1975. Representative spectrum scans from 3600 A to 4500 A (10 A bandpass) and from 6350 A to 6750 A (20 A bandpass) also are shown

  1. Introduction to using neurophysiological signals that reflect cognitive or affective state (Editorial)

    NARCIS (Netherlands)

    Erp, J.B.F. van; Brouwer, A.M.; Zander, T.O.

    2015-01-01

    The central question of this Frontiers Research Topic is: What can we learn from brain and other physiological signals about an individual's cognitive and affective state and how can we use this information? This question reflects three important issues which are addressed by the 22 articles in this

  2. Measurement of splanchnic photoplethysmographic signals using a new reflectance fiber optic sensor

    Science.gov (United States)

    Hickey, Michelle; Samuels, Neal; Randive, Nilesh; Langford, Richard M.; Kyriacou, Panayiotis A.

    2010-03-01

    Splanchnic organs are particularly vulnerable to hypoperfusion. Currently, there is no technique that allows for the continuous estimation of splanchnic blood oxygen saturation (SpO2). As a preliminary to developing a suitable splanchnic SpO2 sensor, a new reflectance fiber optic photoplethysmographic (PPG) sensor and processing system are developed. An experimental procedure to examine the effect of fiber source detector separation distance on acquired PPG signals is carried out before finalizing the sensor design. PPG signals are acquired from four volunteers for separation distances of 1 to 8 mm. The separation range of 3 to 6 mm provides the best quality PPG signals with large amplitudes and the highest signal-to-noise ratios (SNRs). Preliminary calculation of SpO2 shows that distances of 3 and 4 mm provide the most realistic values. Therefore, it is suggested that the separation distance in the design of a fiber optic reflectance pulse oximeter be in the range of 3 to 4 mm. Preliminary PPG signals from various splanchnic organs and the periphery are obtained from six anaesthetized patients. The normalized amplitudes of the splanchnic PPGs are, on average, approximately the same as those obtained simultaneously from the periphery. These observations suggest that fiber optic pulse oximetry may be a valid monitoring technique for splanchnic organs.

  3. Multi-filter spectrophotometry simulations

    Science.gov (United States)

    Callaghan, Kim A. S.; Gibson, Brad K.; Hickson, Paul

    1993-01-01

    To complement both the multi-filter observations of quasar environments described in these proceedings, as well as the proposed UBC 2.7 m Liquid Mirror Telescope (LMT) redshift survey, we have initiated a program of simulated multi-filter spectrophotometry. The goal of this work, still very much in progress, is a better quantitative assessment of the multiband technique as a viable mechanism for obtaining useful redshift and morphological class information from large scale multi-filter surveys.

  4. Temporal analysis of reflected optical signals for short pulse laser interaction with nonhomogeneous tissue phantoms

    International Nuclear Information System (INIS)

    Trivedi, Ashish; Basu, Soumyadipta; Mitra, Kunal

    2005-01-01

    The use of short pulse laser for minimally invasive detection scheme has become an indispensable tool in the technological arsenal of modern medicine and biomedical engineering. In this work, a time-resolved technique has been used to detect tumors/inhomogeneities in tissues by measuring transmitted and reflected scattered temporal optical signals when a short pulse laser source is incident on tissue phantoms. A parametric study involving different scattering and absorption coefficients of tissue phantoms and inhomogeneities, size of inhomogeneity as well as the detector position is performed. The experimental measurements are validated with a numerical solution of the transient radiative transport equation obtained by using discrete ordinates method. Thus, both simultaneous experimental and numerical studies are critical for predicting the optical properties of tissues and inhomogeneities from temporal scattered optical signal measurements

  5. Decadal changes of surface elevation over permafrost area estimated using reflected GPS signals

    Science.gov (United States)

    Liu, Lin; Larson, Kristine M.

    2018-02-01

    Conventional benchmark-based survey and Global Positioning System (GPS) have been used to measure surface elevation changes over permafrost areas, usually once or a few times a year. Here we use reflected GPS signals to measure temporal changes of ground surface elevation due to dynamics of the active layer and near-surface permafrost. Applying the GPS interferometric reflectometry technique to the multipath signal-to-noise ratio data collected by a continuously operating GPS receiver mounted deep in permafrost in Barrow, Alaska, we can retrieve the vertical distance between the antenna and reflecting surface. Using this unique kind of observables, we obtain daily changes of surface elevation during July and August from 2004 to 2015. Our results show distinct temporal variations at three timescales: regular thaw settlement within each summer, strong interannual variability that is characterized by a sub-decadal subsidence trend followed by a brief uplift trend, and a secular subsidence trend of 0.26 ± 0.02 cm year-1 during 2004 and 2015. This method provides a new way to fully utilize data from continuously operating GPS sites in cold regions for studying dynamics of the frozen ground consistently and sustainably over a long time.

  6. Ultraviolet Spectrophotometry of VV Cephei

    Directory of Open Access Journals (Sweden)

    Young Woon Kang

    1992-06-01

    Full Text Available The IUE archival spectra of VV Cephei were collected to investigate the eclipse nature in the ultraviolet. The temperature of the B star has been determined, as approximately 30000K, based on the flux distributions during egress. Light curves of VV Cephei were reduced from the spectrophotometry of the IUE archival spectra. Three light curves at the center wavelengths of 3250 Å, 2550 Å and 2850 Å have been analyzed by the modified Wilson and Devinney light curve program. The radii of the B star and M star were deduced to 0.05 and 0.22 of unit separation, respectively. The UV light curves show an evidence that the light was attenuated by the highly opaque atomsphere of the M star.

  7. Spectrophotometry of Symbiotic Stars (Abstract)

    Science.gov (United States)

    Boyd, D.

    2017-12-01

    (Abstract only) Symbiotic stars are fascinating objects - complex binary systems comprising a cool red giant star and a small hot object, often a white dwarf, both embedded in a nebula formed by a wind from the giant star. UV radiation from the hot star ionizes the nebula, producing a range of emission lines. These objects have composite spectra with contributions from both stars plus the nebula and these spectra can change on many timescales. Being moderately bright, they lend themselves well to amateur spectroscopy. This paper describes the symbiotic star phenomenon, shows how spectrophotometry can be used to extract astrophysically useful information about the nature of these systems, and gives results for three symbiotic stars based on the author's observations.

  8. Responses to olfactory signals reflect network structure of flower-visitor interactions.

    Science.gov (United States)

    Junker, Robert R; Höcherl, Nicole; Blüthgen, Nico

    2010-07-01

    1. Network analyses provide insights into the diversity and complexity of ecological interactions and have motivated conclusions about community stability and co-evolution. However, biological traits and mechanisms such as chemical signals regulating the interactions between individual species--the microstructure of a network--are poorly understood. 2. We linked the responses of receivers (flower visitors) towards signals (flower scent) to the structure of a highly diverse natural flower-insect network. For each interaction, we define link temperature--a newly developed metric--as the deviation of the observed interaction strength from neutrality, assuming that animals randomly interact with flowers. 3. Link temperature was positively correlated to the specific visitors' responses to floral scents, experimentally examined in a mobile olfactometer. Thus, communication between plants and consumers via phytochemical signals reflects a significant part of the microstructure in a complex network. Negative as well as positive responses towards floral scents contributed to these results, where individual experience was important apart from innate behaviour. 4. Our results indicate that: (1) biological mechanisms have a profound impact on the microstructure of complex networks that underlies the outcome of aggregate statistics, and (2) floral scents act as a filter, promoting the visitation of some flower visitors, but also inhibiting the visitation of others.

  9. Reflections

    Directory of Open Access Journals (Sweden)

    Joanne Embree

    2001-01-01

    Full Text Available Ideally, editorials are written one to two months before publication in the Journal. It was my turn to write this one. I had planned to write the first draft the evening after my clinic on Tuesday, September 11. It didn't get done that night or during the next week. Somehow, the topic that I had originally chosen just didn't seem that important anymore as I, along my friends and colleagues, reflected on the changes that the events of that day were likely to have on our lives.

  10. Spectrophotometry (by Barbara Sawrey and Gabriele Wienhausen)

    Science.gov (United States)

    Pringle, David L.

    1998-08-01

    Science Media: San Diego, 1997. 1-10 copies, 99 each; 11-20 copies, 69 each; 21+ copies, $49 each. (Note: CD operates with both Mac and PC.) Spectrophotometry is an interactive CD-ROM which introduces the basics of UV-visible spectrophotometry with some mention of infrared and other forms of spectrophotometry. A Macintosh System 7.5 or higher, CPU 68040 or Power PC processor, 6 megabytes of free RAM, 2.6 megabytes of free disk space, and 4X CD-ROM or faster are required.

  11. A novel algorithm to separate motion artifacts from photoplethysmographic signals obtained with a reflectance pulse oximeter.

    Science.gov (United States)

    Yao, Jianchu; Warren, Steve

    2004-01-01

    Pulse oximeters are mainstays for acquiring blood oxygen saturation in static environments such as hospital rooms. However, motion artifacts prevent their broad in wearable, ambulatory environments. To this end, we present a novel algorithm to separate the motion artifacts from plethysmographic data gathered by pulse oximeters. This algorithm, based on the Beer-Lambert law, requires photoplethysmographic data acquired at three excitation wavelengths. The algorithm can calculate venous blood oxygen saturation (SvO2) as well as arterial blood oxygen saturation (SaO2). Preliminary results indicate that the extraction of the venous signal, which is assumed to be most affected by motions, is successful with data acquired from a reflectance-mode sensor.

  12. Widespread correlation patterns of fMRI signal across visual cortex reflect eccentricity organization

    Science.gov (United States)

    Arcaro, Michael J; Honey, Christopher J; Mruczek, Ryan EB; Kastner, Sabine; Hasson, Uri

    2015-01-01

    The human visual system can be divided into over two-dozen distinct areas, each of which contains a topographic map of the visual field. A fundamental question in vision neuroscience is how the visual system integrates information from the environment across different areas. Using neuroimaging, we investigated the spatial pattern of correlated BOLD signal across eight visual areas on data collected during rest conditions and during naturalistic movie viewing. The correlation pattern between areas reflected the underlying receptive field organization with higher correlations between cortical sites containing overlapping representations of visual space. In addition, the correlation pattern reflected the underlying widespread eccentricity organization of visual cortex, in which the highest correlations were observed for cortical sites with iso-eccentricity representations including regions with non-overlapping representations of visual space. This eccentricity-based correlation pattern appears to be part of an intrinsic functional architecture that supports the integration of information across functionally specialized visual areas. DOI: http://dx.doi.org/10.7554/eLife.03952.001 PMID:25695154

  13. evaluation of atomic absorption spectrophotometry (ashing, non ...

    African Journals Online (AJOL)

    cistvr

    1Department of Agricultural and Food Science and 2Department of ... used techniques, namely atomic absorption spectrophotometry (AAS-Ashing and ..... fact that more preparation steps were involved in the Ashing procedure and thus.

  14. Spectrophotometry of transuranium elements in reprocessing

    International Nuclear Information System (INIS)

    Cauchetier, P.; Guichard, C.; Wagner, J.F.

    1985-06-01

    Quantitative determination of U, Pu and Np at different oxidation degrees by spectrophotometry and problems encountered for industrial applications and automation are reviewed. Work in progress includes memorization of reference spectra, simplification of preliminary treatments of solutions [fr

  15. Absolute spectrophotometry of Nova Cygni 1975

    International Nuclear Information System (INIS)

    Kontizas, E.; Kontizas, M.; Smyth, M.J.

    1976-01-01

    Radiometric photoelectric spectrophotometry of Nova Cygni 1975 was carried out on 1975 August 31, September 2, 3. α Lyr was used as reference star and its absolute spectral energy distribution was used to reduce the spectrophotometry of the nova to absolute units. Emission strengths of Hα, Hβ, Hγ (in W cm -2 ) were derived. The Balmer decrement Hα:Hβ:Hγ was compared with theory, and found to deviate less than had been reported for an earlier nova. (author)

  16. Spectrophotometry of VV Cephei-type systems

    International Nuclear Information System (INIS)

    Piccirillo, J.

    1974-01-01

    Photoelectric spectrophotometry of four VV Cephei-type systems and two related objects is analyzed to derive the visual magnitude differences of the binary components. The results are in good agreement with previous photometric determinations. An extension of the present technique to other types of binary systems is briefly discussed. (U.S.)

  17. Process for neptunium analysis by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Wagner, J.F.

    1987-01-01

    An aqueous solution of a neptunium compounds is treated by a reagent, preferentially a vanadyl sulfate oxidized by cerium IV ions, to obtain neptunium V by oxidation of neptunium IV and reduction of neptunium VI. The reagent is chosen for a negligible absorption at the wavelength used for neptunium V absorption spectrophotometry for instance 981 nm [fr

  18. Evaluation of atomic absorption Spectrophotometry (ashing, non ...

    African Journals Online (AJOL)

    Three commonly used techniques, namely atomic absorption spectrophotometry (AAS-Ashing and AAS-Non Ashing) and titrimetry (potassium permanganate titration) have been evaluated in this study to determine the calcium content in six food samples whose calcium levels ranged from 0 to more than 250mg/100g ...

  19. Spectrophotometry of the Ceres surface

    Science.gov (United States)

    Schröder, Stefan; Mottola, Stefano; Carsenty, Uri; Jaumann, Ralf; Keller, Uwe; Krohn, Katrin; Li, Jian-Yang; Matz, Klaus-Dieter; McFadden, Lucy; Otto, Katharina; Preusker, Frank; Roatsch, Thomas; Scholten, Frank; Stephan, Katrin; Wagner, Roland; Raymond, Carol; Russell, Chris

    2015-11-01

    The Dawn spacecraft is in orbit around dwarf planet Ceres. The onboard Framing Camera (FC) is mapping the surface through a clear filter and 7 narrow-band filters at various observational geometries and image resolutions. Generally, Ceres' appearance in these images is affected by shadows and shading, effects which obscure the intrinsic reflective properties of the surface. By means of photometric modeling we remove these effects and reconstruct the surface reflectance for each of the FC filters, creating albedo and color maps in the process. Considering these maps in unison provides clues to the physical nature and composition of the surface and the dominant geologic processes that shape the surface. We assess the nature of color variations in the visible wavelength range for Ceres globally. We identify which terrains express the dominant colors and investigate why some areas are exceptions to the rule. By correlating the color over the surface with geologic units we find an relatively strong enhancement of the reflectance towards the blue end of the visible spectrum for recent impacts and their ejecta.

  20. Reply to 'Comment on 'The evidence for a pentaquark signal and kinematic reflections''

    International Nuclear Information System (INIS)

    Dzierba, A.R.; Krop, D.; Swat, M.; Teige, S.; Szczepaniak, A.P.

    2005-01-01

    The quantitative aspects of the model used, together with kinematic reflections to explain the K + n spectrum in K + K - photoproduction on deuterium, were recently criticized. Here we respond to these criticisms

  1. Calculating the reduced scattering coefficient of turbid media from a single optical reflectance signal

    Science.gov (United States)

    Johns, Maureen; Liu, Hanli

    2003-07-01

    When light interacts with tissue, it can be absorbed, scattered or reflected. Such quantitative information can be used to characterize the optical properties of tissue, differentiate tissue types in vivo, and identify normal versus diseased tissue. The purpose of this research is to develop an algorithm that determines the reduced scattering coefficient (μs") of tissues from a single optical reflectance spectrum with a small source-detector separation. The basic relationship between μs" and optical reflectance was developed using Monte Carlo simulations. This produced an analytical equation containing μs" as a function of reflectance. To experimentally validate this relationship, a 1.3-mm diameter fiber optic probe containing two 400-micron diameter fibers was used to deliver light to and collect light from Intralipid solutions of various concentrations. Simultaneous measurements from optical reflectance and an ISS oximeter were performed to validate the calculated μs" values determined by the reflectance measurement against the 'gold standard" ISS readings. The calculated μs" values deviate from the expected values by approximately -/+ 5% with Intralipid concentrations between 0.5 - 2.5%. The scattering properties within this concentration range are similar to those of in vivo tissues. Additional calculations are performed to determine the scattering properties of rat brain tissues and to discuss accuracy of the algorithm for measured samples with a broad range of the absorption coefficient (μa).

  2. Classification of reflected signals from cavitated tooth surfaces using an artificial intelligence technique incorporating a fiber optic displacement sensor

    Science.gov (United States)

    Rahman, Husna Abdul; Harun, Sulaiman Wadi; Arof, Hamzah; Irawati, Ninik; Musirin, Ismail; Ibrahim, Fatimah; Ahmad, Harith

    2014-05-01

    An enhanced dental cavity diameter measurement mechanism using an intensity-modulated fiber optic displacement sensor (FODS) scanning and imaging system, fuzzy logic as well as a single-layer perceptron (SLP) neural network, is presented. The SLP network was employed for the classification of the reflected signals, which were obtained from the surfaces of teeth samples and captured using FODS. Two features were used for the classification of the reflected signals with one of them being the output of a fuzzy logic. The test results showed that the combined fuzzy logic and SLP network methodology contributed to a 100% classification accuracy of the network. The high-classification accuracy significantly demonstrates the suitability of the proposed features and classification using SLP networks for classifying the reflected signals from teeth surfaces, enabling the sensor to accurately measure small diameters of tooth cavity of up to 0.6 mm. The method remains simple enough to allow its easy integration in existing dental restoration support systems.

  3. Spectrophotometry of the QSO NRAO 530

    International Nuclear Information System (INIS)

    Junkkarinen, V.

    1984-01-01

    Spectrophotometry of the QSO NRAO 530 with the KPNO Cryogenic Camera is reported. A redshift of 0.902 is determined from the H-beta, H-gamma, and 3727 A forbidden O II emission lines, confirming a redshift that had been based on a single line, the 2798 A Mg II. The H-beta equivalent is smaller than in normal QSOs, which may be characteristic of optically variable QSOs. 16 references

  4. Spectrophotometry of the Seyfert galaxy NGC 4593

    International Nuclear Information System (INIS)

    MacAlpine, G.M.; Williams, G.A.; Lewis, D.W.

    1979-01-01

    Spectrophotometry of the bright class 1 Seyfert galaxy NGC 4593 is presented. The emission-line characteristics are briefly discussed and compared with those of other Seyfert galaxies. The measured hydrogen Balmer-line ratios are reasonably consistent with expected recombination values, and the emission intensities of Fe II, He I 5876, and forbidden O III 4363 relative to other lines are stronger than average in NGC 4593

  5. Absolute spectrophotometry of the β Lyr

    International Nuclear Information System (INIS)

    Burnashev, V.I.; Skul'skij, M.Yu.

    1978-01-01

    In 1974 an absolute spectrophotometry of β Lyr was performed with the scanning spectrophotometer in the 3300-7400 A range. The energy distribution in the β Lyr spectrum is obtained. The β Lyr model is proposed. It is shown, that the continuous spectrum of the β Lyr radiation can be presented by the total radiation of the B8 3 and A5 3 two stars and of the gaseous envelope with Te =20000 K

  6. Objective-prism spectrophotometry of quasars

    International Nuclear Information System (INIS)

    Clowes, R.G.

    1980-01-01

    A procedure is derived for obtaining low-resolution spectrophotometry of quasars directly from the objective-prism plates on which they were discovered. Measurements with a PDS microdensitometer of approximately 130 quasar candidates in approximately the central 19 square degrees of the UK Schmidt prism plate UJ3682P were used in the application of the procedure. The success of the objective-prism spectrophotometry is demonstrated in a comparison with 12 slit spectra. Redshifts and equivalent widths can be determined with typical discrepancies of 1% and 40% respectively. This work on objective-prism spectrophotometry leads to a quantification of the selection effects that operate in the searches for emission-line objects on objective-prism plates. The quantification successfully explains an apparent discrepancy in the detection efficiencies of the CTIO-4m and Curtis Schmidt surveys for quasars. Spectra of quasars that were observed with the Image Photon Counting System on the Anglo-Australian Telescope are presented. The observations of quasars with broad absorption troughs indicate the ejection of matter with velocities up to approximately 22000kms -1 and with velocity dispersions up to approximately 11000kms -1 . Data on the wavelength dependences of the contrast γ and the grain response function g of the Kodak emulsion IIIaJ are presented. (author)

  7. Autofluorescence Imaging With Near-Infrared Excitation:Normalization by Reflectance to Reduce Signal From Choroidal Fluorophores

    Science.gov (United States)

    Cideciyan, Artur V.; Swider, Malgorzata; Jacobson, Samuel G.

    2015-01-01

    Purpose. We previously developed reduced-illuminance autofluorescence imaging (RAFI) methods involving near-infrared (NIR) excitation to image melanin-based fluorophores and short-wavelength (SW) excitation to image lipofuscin-based flurophores. Here, we propose to normalize NIR-RAFI in order to increase the relative contribution of retinal pigment epithelium (RPE) fluorophores. Methods. Retinal imaging was performed with a standard protocol holding system parameters invariant in healthy subjects and in patients. Normalized NIR-RAFI was derived by dividing NIR-RAFI signal by NIR reflectance point-by-point after image registration. Results. Regions of RPE atrophy in Stargardt disease, AMD, retinitis pigmentosa, choroideremia, and Leber congenital amaurosis as defined by low signal on SW-RAFI could correspond to a wide range of signal on NIR-RAFI depending on the contribution from the choroidal component. Retinal pigment epithelium atrophy tended to always correspond to high signal on NIR reflectance. Normalizing NIR-RAFI reduced the choroidal component of the signal in regions of atrophy. Quantitative evaluation of RPE atrophy area showed no significant differences between SW-RAFI and normalized NIR-RAFI. Conclusions. Imaging of RPE atrophy using lipofuscin-based AF imaging has become the gold standard. However, this technique involves bright SW lights that are uncomfortable and may accelerate the rate of disease progression in vulnerable retinas. The NIR-RAFI method developed here is a melanin-based alternative that is not absorbed by opsins and bisretinoid moieties, and is comfortable to view. Further development of this method may result in a nonmydriatic and comfortable imaging method to quantify RPE atrophy extent and its expansion rate. PMID:26024124

  8. Traces of exomoons in flux and polarization signals of starlight reflected by exoplanets

    NARCIS (Netherlands)

    Berzosa Molina (student TUDelft), Javier; Stam, D.M.; Rossi, L.C.G.

    2017-01-01

    The detection of moons around extrasolar planets is one of the main focuses of current and future observatories. These silent companions contribute to the planets' observed signals but are barely detectable with current methods. Numerous gaseous exoplanets are known to orbit in the habitable zones

  9. Signal improvement in multiphoton microscopy by reflection with simple mirrors near the sample

    Science.gov (United States)

    Rehberg, Markus; Krombach, Fritz; Pohl, Ulrich; Dietzel, Steffen

    2010-03-01

    In conventional fluorescence or confocal microscopy, emitted light is generated not only in the focal plane but also above and below. The situation is different in multiphoton-induced fluorescence and multiphoton-induced higher harmonic generation. Here, restriction of signal generation to a single focal point permits that all emitted photons can contribute to image formation if collected, regardless of their path through the specimen. Often, the intensity of the emitted light is rather low in biological specimens. We present a method to significantly increase the fraction of photons collected by an epi (backward) detector by placing a simple mirror, an aluminum-coated coverslip, directly under the sample. Samples investigated include fluorescent test slides, collagen gels, and thin-layered, intact mouse skeletal muscles. Quantitative analysis revealed an intensity increase of second- and third-harmonic generated signal in skeletal muscle of nine- and sevenfold respectively, and of fluorescent signal in test slides of up to twofold. Our approach thus allows significant signal improvement also for situations were a forward detection is impossible, e.g., due to the anatomy of animals in intravital microscopy.

  10. Discrimination techniques employing both reflective and thermal multispectral signals. [for remote sensor technology

    Science.gov (United States)

    Malila, W. A.; Crane, R. B.; Richardson, W.

    1973-01-01

    Recent improvements in remote sensor technology carry implications for data processing. Multispectral line scanners now exist that can collect data simultaneously and in registration in multiple channels at both reflective and thermal (emissive) wavelengths. Progress in dealing with two resultant recognition processing problems is discussed: (1) More channels mean higher processing costs; to combat these costs, a new and faster procedure for selecting subsets of channels has been developed. (2) Differences between thermal and reflective characteristics influence recognition processing; to illustrate the magnitude of these differences, some explanatory calculations are presented. Also introduced, is a different way to process multispectral scanner data, namely, radiation balance mapping and related procedures. Techniques and potentials are discussed and examples presented.

  11. ENERGY-EFFICIENT PASSIVE ANTENNA CODE PULSE MODULATION DUE TO THE REFLECTION OF MICROWAVE SIGNAL

    Directory of Open Access Journals (Sweden)

    T. A. Ismailov

    2015-01-01

    Full Text Available The article describes an antenna in a corner reflector with a p-i-n-diodes, integrated with the housing transceiver, which allows not only to provide bidirectional communication with the base station as a result of multipath radio three times, but with minimal energy consumption to provide digitally transmit information on the reflected wave flow of any complexity, which allow to eliminate energy in the transmit path and extend the life of the device. 

  12. Racial Variations in Prostate Cancer Molecular Subtypes and Androgen Receptor Signaling Reflect Anatomic Tumor Location.

    Science.gov (United States)

    Faisal, Farzana A; Sundi, Debasish; Tosoian, Jeffrey J; Choeurng, Voleak; Alshalalfa, Mohammed; Ross, Ashley E; Klein, Eric; Den, Robert; Dicker, Adam; Erho, Nicholas; Davicioni, Elai; Lotan, Tamara L; Schaeffer, Edward M

    2016-07-01

    Prostate cancer (PCa) subtypes based on ETS gene expression have been described. Recent studies suggest there are racial differences in tumor location, with PCa located anteriorly more often among African-American (AA) compared to Caucasian-American (CA) men. In this retrospective analysis of a multi-institutional cohort treated by radical prostatectomy (179 CA, 121 AA), we evaluated associations among molecular subtype, race, anatomic tumor location, and androgen receptor (AR) signaling. Subtype (m-ERG(+), m-ETS(+), m-SPINK1(+), or triple-negative) was determined using distribution-based outlier analysis. AR signaling was investigated using gene expression profiling of canonical AR targets. m-ERG(+) was more common in CA than AA men (47% vs 22%, pprostate cancer molecular subtypes, and tumor location. Location-specific differences in androgen regulation may further underlie these relationships. Copyright © 2015. Published by Elsevier B.V.

  13. Moment-to-Moment BOLD Signal Variability Reflects Regional Changes in Neural Flexibility across the Lifespan.

    Science.gov (United States)

    Nomi, Jason S; Bolt, Taylor S; Ezie, C E Chiemeka; Uddin, Lucina Q; Heller, Aaron S

    2017-05-31

    Variability of neuronal responses is thought to underlie flexible and optimal brain function. Because previous work investigating BOLD signal variability has been conducted within task-based fMRI contexts on adults and older individuals, very little is currently known regarding regional changes in spontaneous BOLD signal variability in the human brain across the lifespan. The current study used resting-state fMRI data from a large sample of male and female human participants covering a wide age range (6-85 years) across two different fMRI acquisition parameters (TR = 0.645 and 1.4 s). Variability in brain regions including a key node of the salience network (anterior insula) increased linearly across the lifespan across datasets. In contrast, variability in most other large-scale networks decreased linearly over the lifespan. These results demonstrate unique lifespan trajectories of BOLD variability related to specific regions of the brain and add to a growing literature demonstrating the importance of identifying normative trajectories of functional brain maturation. SIGNIFICANCE STATEMENT Although brain signal variability has traditionally been considered a source of unwanted noise, recent work demonstrates that variability in brain signals during task performance is related to brain maturation in old age as well as individual differences in behavioral performance. The current results demonstrate that intrinsic fluctuations in resting-state variability exhibit unique maturation trajectories in specific brain regions and systems, particularly those supporting salience detection. These results have implications for investigations of brain development and aging, as well as interpretations of brain function underlying behavioral changes across the lifespan. Copyright © 2017 the authors 0270-6474/17/375539-10$15.00/0.

  14. Quantitative analysis of phosphoinositide 3-kinase (PI3K) signaling using live-cell total internal reflection fluorescence (TIRF) microscopy.

    Science.gov (United States)

    Johnson, Heath E; Haugh, Jason M

    2013-12-02

    This unit focuses on the use of total internal reflection fluorescence (TIRF) microscopy and image analysis methods to study the dynamics of signal transduction mediated by class I phosphoinositide 3-kinases (PI3Ks) in mammalian cells. The first four protocols cover live-cell imaging experiments, image acquisition parameters, and basic image processing and segmentation. These methods are generally applicable to live-cell TIRF experiments. The remaining protocols outline more advanced image analysis methods, which were developed in our laboratory for the purpose of characterizing the spatiotemporal dynamics of PI3K signaling. These methods may be extended to analyze other cellular processes monitored using fluorescent biosensors. Copyright © 2013 John Wiley & Sons, Inc.

  15. Exercise-intensity dependent alterations in plasma redox status do not reflect skeletal muscle redox-sensitive protein signaling.

    Science.gov (United States)

    Parker, Lewan; Trewin, Adam; Levinger, Itamar; Shaw, Christopher S; Stepto, Nigel K

    2018-04-01

    Redox homeostasis and redox-sensitive protein signaling play a role in exercise-induced adaptation. The effects of sprint-interval exercise (SIE), high-intensity interval exercise (HIIE) and continuous moderate-intensity exercise (CMIE), on post-exercise plasma redox status are unclear. Furthermore, whether post-exercise plasma redox status reflects skeletal muscle redox-sensitive protein signaling is unknown. In a randomized crossover design, eight healthy adults performed a cycling session of HIIE (5×4min at 75% W max ), SIE (4×30s Wingate's), and CMIE work-matched to HIIE (30min at 50% of W max ). Plasma hydrogen peroxide (H 2 O 2 ), thiobarbituric acid reactive substances (TBARS), superoxide dismutase (SOD) activity, and catalase activity were measured immediately post, 1h, 2h and 3h post-exercise. Plasma redox status biomarkers were correlated with phosphorylation of skeletal muscle p38-MAPK, JNK, NF-κB, and IκBα protein content immediately and 3h post-exercise. Plasma catalase activity was greater with SIE (56.6±3.8Uml -1 ) compared to CMIE (42.7±3.2, pexercise plasma TBARS and SOD activity significantly (pexercise protocol. A significant positive correlation was detected between plasma catalase activity and skeletal muscle p38-MAPK phosphorylation 3h post-exercise (r=0.40, p=0.04). No other correlations were detected (all p>0.05). Low-volume SIE elicited greater post-exercise plasma catalase activity compared to HIIE and CMIE, and greater H 2 O 2 compared to CMIE. Plasma redox status did not, however, adequately reflect skeletal muscle redox-sensitive protein signaling. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Deriving surface soil moisture from reflected GNSS signal observations from a grassland site in southwestern France

    Science.gov (United States)

    Zhang, Sibo; Calvet, Jean-Christophe; Darrozes, José; Roussel, Nicolas; Frappart, Frédéric; Bouhours, Gilles

    2018-03-01

    This work assesses the estimation of surface volumetric soil moisture (VSM) using the global navigation satellite system interferometric reflectometry (GNSS-IR) technique. Year-round observations were acquired from a grassland site in southwestern France using an antenna consecutively placed at two contrasting heights above the ground surface (3.3 and 29.4 m). The VSM retrievals are compared with two independent reference datasets: in situ observations of soil moisture, and numerical simulations of soil moisture and vegetation biomass from the ISBA (Interactions between Soil, Biosphere and Atmosphere) land surface model. Scaled VSM estimates can be retrieved throughout the year removing vegetation effects by the separation of growth and senescence periods and by the filtering of the GNSS-IR observations that are most affected by vegetation. Antenna height has no significant impact on the quality of VSM estimates. Comparisons between the VSM GNSS-IR retrievals and the in situ VSM observations at a depth of 5 cm show good agreement (R2 = 0.86 and RMSE = 0.04 m3 m-3). It is shown that the signal is sensitive to the grass litter water content and that this effect triggers differences between VSM retrievals and in situ VSM observations at depths of 1 and 5 cm, especially during light rainfall events.

  17. Deriving surface soil moisture from reflected GNSS signal observations from a grassland site in southwestern France

    Directory of Open Access Journals (Sweden)

    S. Zhang

    2018-03-01

    Full Text Available This work assesses the estimation of surface volumetric soil moisture (VSM using the global navigation satellite system interferometric reflectometry (GNSS-IR technique. Year-round observations were acquired from a grassland site in southwestern France using an antenna consecutively placed at two contrasting heights above the ground surface (3.3 and 29.4 m. The VSM retrievals are compared with two independent reference datasets: in situ observations of soil moisture, and numerical simulations of soil moisture and vegetation biomass from the ISBA (Interactions between Soil, Biosphere and Atmosphere land surface model. Scaled VSM estimates can be retrieved throughout the year removing vegetation effects by the separation of growth and senescence periods and by the filtering of the GNSS-IR observations that are most affected by vegetation. Antenna height has no significant impact on the quality of VSM estimates. Comparisons between the VSM GNSS-IR retrievals and the in situ VSM observations at a depth of 5 cm show good agreement (R2 =  0.86 and RMSE  =  0.04 m3 m−3. It is shown that the signal is sensitive to the grass litter water content and that this effect triggers differences between VSM retrievals and in situ VSM observations at depths of 1 and 5 cm, especially during light rainfall events.

  18. Micro-lightguide spectrophotometry for tissue perfusion in ischemic limbs

    DEFF Research Database (Denmark)

    Jørgensen, Lise Pyndt; Schroeder, Torben V

    2012-01-01

    To validate micro-lightguide spectrophotometry (O2C) in patients with lower limb ischemia and to compare results with those obtained from toe blood pressure.......To validate micro-lightguide spectrophotometry (O2C) in patients with lower limb ischemia and to compare results with those obtained from toe blood pressure....

  19. Monitoring of monosaccharides, oligosaccharides, ethanol and glycerol during wort fermentation by biosensors, HPLC and spectrophotometry.

    Science.gov (United States)

    Monošík, Rastislav; Magdolen, Peter; Stredanský, Miroslav; Šturdík, Ernest

    2013-05-01

    The aim of the present study was to analyze sugar levels (namely maltose, maltotriose, glucose and fructose) and alcohols (ethanol and glycerol) during the fermentation process in wort samples by amperometric enzymatic biosensors developed by our research group for industrial application, HPLC and spectrophotometry, and to compare the suitability of the presented methods for determination of individual analytes. We can conclude that for the specific monitoring of maltose or maltotriose only the HPLC method was suitable. On the other hand, biosensors and spectrophotometry reflected a decrease in total sugar concentration better and were able to detect both glucose and fructose in the later stages of fermentation, while HPLC was not. This can be attributed to the low detection limits and good sensitivity of the proposed methods. For the ethanol and glycerol analysis all methods proved to be suitable. However, concerning the cost expenses and time analysis, biosensors represented the best option. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Spectrophotometry of peculiar B and A stars

    International Nuclear Information System (INIS)

    Adelman, S.J.

    1980-01-01

    Spectrophotometry of the optical region lambda lambda 3300-7100 is presented for seven magnetic Ap stars: HD 32650, 84 Ursa Majoris, HD 149822, 19 Lyrae, 4 Cygni, HD 196178, and 108 Aquarii. The energy distributions of all seven stars show definite lambda 4200 and lambda 5200 broad, continuum features as well as other more subtle deviations from the predictions of normal stellar atmospheres. The observations of HD 32650 violate the general rule for the Ap stars that the temperature found by comparing the Balmer jump regions with the predictions of normal stalle atmospheres with log g = 4.0 are systematically greater than those found from fitting the slopes of the Paschen continua. (orig.)

  1. Optical imagery and spectrophotometry of CTB 80

    Science.gov (United States)

    Hester, J. Jeff; Kulkarni, Shrinivas R.

    1989-01-01

    Narrow-band imagery and spectrophotometry of the central region of CTB 80 are presented. The images show weak forbidden O III and ubiquitous filamentary forbidden S II and H-alpha emission from the extended radio lobes in which the core is embedded. The data indicate that the extended component is shock heated. Balmer line-dominated emission is observed around the perimeter of the core. Assuming that the volume of the radio shell is similar to the volume of the thermal shell, it is found that a magnetic field of about 600 microG and a cosmic-ray proton-to-electron ratio of about 200 are required to explain the pressure and synchrotron volume emissivity in the radio shell. It is suggested that the optical emission form the core of CTB 80 arises behind shocks which are being driven into a magnetized thermal plasma by the confined relativistic wind from PSR 1951+32.

  2. Spectrophotometry of the shell around AG Carinae

    Science.gov (United States)

    Mitra, P. Mila; Dufour, Reginald J.

    1990-01-01

    Spatially-resolved long-slit spectrophotometry are presented for two regions of the shell nebula around the P-Cygni variable star AG Carinae. The spectra cover the 3700-6800 A wavelength range. Emission-line diagnostics are used to derive extinction, electron temperatures, and densities for various positions in the nebula. The chemical abundances and ionization structure are calculated and compared with other types of planetary nebulae and shells around other luminous stars. It is found that the N/O and N/S ratios of Ag Car are high compared to solar neighborhood ISM values. The O/H depletion found for the AG Car shell approaches that found in the condensations of the Eta Car system.

  3. Early-onset sleep defects in Drosophila models of Huntington's disease reflect alterations of PKA/CREB signaling

    Science.gov (United States)

    Gonzales, Erin D.; Tanenhaus, Anne K.; Zhang, Jiabin; Chaffee, Ryan P.; Yin, Jerry C.P.

    2016-01-01

    Huntington's disease (HD) is a progressive neurological disorder whose non-motor symptoms include sleep disturbances. Whether sleep and activity abnormalities are primary molecular disruptions of mutant Huntingtin (mutHtt) expression or result from neurodegeneration is unclear. Here, we report Drosophila models of HD exhibit sleep and activity disruptions very early in adulthood, as soon as sleep patterns have developed. Pan-neuronal expression of full-length or N-terminally truncated mutHtt recapitulates sleep phenotypes of HD patients: impaired sleep initiation, fragmented and diminished sleep, and nighttime hyperactivity. Sleep deprivation of HD model flies results in exacerbated sleep deficits, indicating that homeostatic regulation of sleep is impaired. Elevated PKA/CREB activity in healthy flies produces patterns of sleep and activity similar to those in our HD models. We were curious whether aberrations in PKA/CREB signaling were responsible for our early-onset sleep/activity phenotypes. Decreasing signaling through the cAMP/PKA pathway suppresses mutHtt-induced developmental lethality. Genetically reducing PKA abolishes sleep/activity deficits in HD model flies, restores the homeostatic response and extends median lifespan. In vivo reporters, however, show dCREB2 activity is unchanged, or decreased when sleep/activity patterns are abnormal, suggesting dissociation of PKA and dCREB2 occurs early in pathogenesis. Collectively, our data suggest that sleep defects may reflect a primary pathological process in HD, and that measurements of sleep and cAMP/PKA could be prodromal indicators of disease, and serve as therapeutic targets for intervention. PMID:26604145

  4. Effective signaling of surface boundaries by L-vertices reflect the consistency of their contrast in natural images.

    Science.gov (United States)

    Vessel, Edward A; Biederman, Irving; Subramaniam, Suresh; Greene, Michelle R

    2016-07-01

    An L-vertex, the point at which two contours coterminate, provides highly reliable evidence that a surface terminates at that vertex, thus providing the strongest constraint on the extraction of shape from images (Guzman, 1968). Such vertices are pervasive in our visual world but the importance of a statistical regularity about them has been underappreciated: The contours defining the vertex are (almost) always of the same direction of contrast with respect to the background (i.e., both darker or both lighter). Here we show that when the two contours are of different directions of contrast, the capacity of the L-vertex to signal the termination of a surface, as reflected in object recognition, is markedly reduced. Although image statistics have been implicated in determining the connectivity in the earliest cortical visual stage (V1) and in grouping during visual search, this finding provides evidence that such statistics are involved in later stages where object representations are derived from two-dimensional images.

  5. On image tube spectrophotometry of weak emission lines

    International Nuclear Information System (INIS)

    Duflot, R.

    1979-01-01

    The usual precision of image tube spectrophotometry measures relative to low intensity lines can be improved by the 'method of two lines'. This operating process tested on H II galactic regions leads to a precision of 13%. (Auth.)

  6. Impurities determination of uranium metal flame spectrophotometry and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Rukihati.

    1978-01-01

    The atomic absorption flame spectrophotometry has been applied to the determination of chromium, copper, iron, lead, manganese and nickel in the metal of uranium. The first step to be done is to dissolve the uranium sample in nitric acid and then the uranium is extracted by a tributylphosphate-carbon tetrachloride solution. The aqueous phase which contains the chromium, copper, iron, lead, manganese and nickel is aspirated into an airacetylene flame. The results of this method are compared with the results of emission spectrographic method. It is found that this technique is competative to other methods in the sense that it is quite fast and accurate. (author)

  7. Ultraviolet reflecting photonic microstructures in the King Penguin beak.

    Science.gov (United States)

    Dresp, Birgitta; Jouventin, Pierre; Langley, Keith

    2005-09-22

    King and emperor penguins (Aptenodytes patagonicus and Aptenodytes forsteri) are the only species of marine birds so far known to reflect ultraviolet (UV) light from their beaks. Unlike humans, most birds perceive UV light and several species communicate using the near UV spectrum. Indeed, UV reflectance in addition to the colour of songbird feathers has been recognized as an important signal when choosing a mate. The king penguin is endowed with several highly coloured ornaments, notably its beak horn and breast and auricular plumage, but only its beak reflects UV, a property considered to influence its sexual attraction. Because no avian UV-reflecting pigments have yet been identified, the origin of such reflections is probably structural. In an attempt to identify the structures that give rise to UV reflectance, we combined reflectance spectrophotometry and morphological analysis by both light and electron microscopy, after experimental removal of surface layers of the beak horn. Here, we characterize for the first time a multilayer reflector photonic microstructure that produces the UV reflections in the king penguin beak.

  8. Acid-Base Properties of Azo Dyes in Solution Studied Using Spectrophotometry and Colorimetry

    Science.gov (United States)

    Snigur, D. V.; Chebotarev, A. N.; Bevziuk, K. V.

    2018-03-01

    Colorimetry and spectrophotometry with chemometric data processing were used to study the acid-base properties of azo dyes in aqueous solution. The capabilities of both methods were compared. Ionization constants of all the functional groups of the azo compounds studied could be determined relative to the change in the specific color difference depending on the acidity of the medium. The colorimetric functions of ion-molecular forms of azo compounds used as an analytical signal allow us to obtain complete information on the acid-base equilibrium in a wide acidity range.

  9. Technical note: comparing von Luschan skin color tiles and modern spectrophotometry for measuring human skin pigmentation.

    Science.gov (United States)

    Swiatoniowski, Anna K; Quillen, Ellen E; Shriver, Mark D; Jablonski, Nina G

    2013-06-01

    Prior to the introduction of reflectance spectrophotometry into anthropological field research during the 1950s, human skin color was most commonly classified by visual skin color matching using the von Luschan tiles, a set of 36 standardized, opaque glass tiles arranged in a chromatic scale. Our goal was to establish a conversion formula between the tile-based color matching method and modern reflectance spectrophotometry to make historical and contemporary data comparable. Skin pigmentation measurements were taken on the forehead, inner upper arms, and backs of the hands using both the tiles and a spectrophotometer on 246 participants showing a broad range of skin pigmentation. From these data, a second-order polynomial conversion formula was derived by jackknife analysis to estimate melanin index (M-index) based on tile values. This conversion formula provides a means for comparing modern data to von Luschan tile measurements recorded in historical reports. This is particularly important for populations now extinct, extirpated, or admixed for which tile-based measures of skin pigmentation are the only data available. Copyright © 2013 Wiley Periodicals, Inc.

  10. Derivative spectrophotometry applied to solutions of complex composition

    International Nuclear Information System (INIS)

    Perfil'ev, V.A.

    1986-01-01

    The authors consider not only the basic principles of derivative spectrophotometry but also survey the data on its use in research on the properties of materials, the compositions of compounds, and the structures of complex chemical systems. Recording methods by which derivative spectra can be generated include descriptions of electronic differentiation, computer spectrum differentiation, wavelength modulation, and the two-way derivative method. A section on the advantages of derivative spectrophotometry presents a discussion on features enabling one to determine various substances from their characteristic absorption spectra without performing complicated operations to isolate or separate the components. Other topics include research on the structures of substances and metal-ion complexing in solutions, derivative spectrophotometry in gas analysis, gas determination, and determining organic and compounds

  11. Near-simultaneous optical and infrared spectrophotometry of active galaxies

    International Nuclear Information System (INIS)

    Yates, M.G.; Garden, R.P.

    1989-01-01

    We present optical and infrared spectrophotometry for a sample of eight optically bright quasars, and the broad-line radio galaxy (BLRG) 3C 120. The optical and infrared spectrophotometry is separated by only five weeks, thus we have been able to minimize uncertainties due to variations in the objects. We compare our observed Paα/Hα and Hα/Hβ ratios with a large number of current photoionization models. We find that none of these models are able to reproduce our observed values of Paα/Hα in any of the active galaxies except the quasars 3C 273 and 0736+017. (author)

  12. Ion-exchanger ultraviolet spectrophotometry for uranium(VI)

    International Nuclear Information System (INIS)

    Waki, H.; Korkisch, J.

    1983-01-01

    A sensitive method based on solid-phase spectrophotometry has been developed for the microdetermination of uranium(VI) in water samples. Uranium is sorbed on the anion-exchanger QAE-Sephadex from thiocyanate solution and the absorbance of the exchanger is measured at 300 nm. This method is about 30 times more sensitive than solution spectrophotometry. Absorption spectra of various metals in the anion-exchanger phase are presented and their interferences discussed. A procedure for the cation-exchange separation of uranium from accompanying elements before spectral measurement of uranium is proposed. (author)

  13. Multi-filter spectrophotometry of quasar environments

    Science.gov (United States)

    Craven, Sally E.; Hickson, Paul; Yee, Howard K. C.

    1993-01-01

    A many-filter photometric technique for determining redshifts and morphological types, by fitting spectral templates to spectral energy distributions, has good potential for application in surveys. Despite success in studies performed on simulated data, the results have not been fully reliable when applied to real, low signal-to-noise data. We are investigating techniques to improve the fitting process.

  14. Fourier transform infrared spectrophotometry and X-ray powder ...

    African Journals Online (AJOL)

    This study aimed at demonstrating complementary roles offered by both Fourier transform infrared (FTIR) spectrophotometry and x-ray powder diffraction (XRPD) techniques in characterizing clay size fraction of kaolins. The clay size fraction of kaolin samples obtained from Kgwakgwe, Makoro, Lobatse and Serule kaolin ...

  15. An important improvement in Ferron-timed spectrophotometry

    NARCIS (Netherlands)

    Zhang, Jing; Chang, Fang; Ren, Yijin; Shi, Qiuyi

    Ferron dosage ([Ferron]) is key to ferron-timed spectrophotometry (ferron assay). In order to clarify some important questions, the following studies were conducted: (1) The effect of [Ferron] on the sensitivity of total aluminum (AlT) determination was experimentally investigated and ²⁷Al nuclear

  16. A Computer-aided Learning Exercise in Spectrophotometry.

    Science.gov (United States)

    Pamula, Frederick

    1994-01-01

    Discusses the use of a computer simulation program in teaching the concepts of spectrophotometry. Introduces several parts of the program and program usage. Presents an assessment activity to evaluate students' mastery of material. Concludes with the advantages of this approach to the student and to the assessor. (ASK)

  17. The determination of copper in biological materials by flame spectrophotometry

    Science.gov (United States)

    Newman, G. E.; Ryan, M.

    1962-01-01

    A method for the determination of the copper content of biological materials by flame spectrophotometry is described. The effects of interference by ions such as sodium and phosphate were eliminated by isolating copper as the dithizonate in CCl4. Results obtained for the urinary excretion of copper by a patient with Wilson's disease before and after treatment with penicillamine are reported. PMID:14479334

  18. Spectrophotometry of CRL 2688 from 2 to 24 microns

    International Nuclear Information System (INIS)

    Forrest, W.J.; Merrill, K.M.; Russell, R.W.; Soifer, B.T.

    1975-01-01

    Medium-resolution spectrophotometry (Δlambda/lambdaapprox. =0.01) of CRL 2688 from 2 μ to 24 μ are reported. No significant features are found from 3 μ to 24 μ, although the spectral flux distribution is broader than that of a single-temperature blackbody

  19. Spectrophotometry of four galaxies of high surface brightness

    International Nuclear Information System (INIS)

    Arakelyan, M.A.; Magtesyan, A.P.

    1982-01-01

    Spectrophotometry has been performed for the emission lines in the nuclei of Arakelyan galaxies Nos. 428, 449, 454, 532. In the first two objects, H II clouds occur roughly-equal2 kpc out from the nucleus. No. 449 may contain another cloud moving at roughly-equal1500 km/sec radial velocity. radial

  20. Zirconium determination in rocks by solid-phase spectrophotometry

    International Nuclear Information System (INIS)

    Brykina, G.D.; Lebedeva, G.G.; Agapova, G.F.; AN SSSR, Moscow

    1990-01-01

    A method was developed for determination of zirconium in rocks by solid-phase spectrophotometry using AV-17x8-Cl anion exchanger modified with xylenol orange. Relative standard deviation at the level of (2-4.9)x10 -3 % ZrO 2 was about 0.245

  1. The determination of zirconium by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Rodriguez, E.R.; Cunha, M.T.C. da

    1975-01-01

    The interference of iron in the determination of zirconium by atomic absorption spectrophotometry was studied. Attempts were made to emininate this interference by complexing the iron with EDTA, ascorbic acid and hydrazine; also by the addition of ammonium fluoride to the solution. Some experiments were carried out in order to explain the results obtained [pt

  2. Evolution of Instrumentation for UV-Visible Spectrophotometry. Part I.

    Science.gov (United States)

    Altemose, Ines R.

    1986-01-01

    Traces the development of instruments used in spectrophotometry. Discusses how spectrophotometric measurements are made. Describes the color comparator, the filter photometer, and the spectrophotometer. Outlines the evolution of optical systems, including light sources, the monochromator, the photodetector, double-beam optics, and split-beam…

  3. Photochemical reaction monitoring by ultra-violet spectrophotometry.

    Science.gov (United States)

    Roig, B; Touraud, E; Thomas, O

    2002-11-01

    Within the framework of the monitoring of the trichloroacetylchloride (TCAC) photosynthesis, ultra-violet (UV) spectrophotometry is proposed as a simple and rapid tool allowing, in real time, the control of the process efficiency. A good correlation has been obtained between the results acquired by this alternative method and the standard gas chromatography.

  4. Heterodyne spectrophotometry of ozone in the 9.6-micron band using a tunable diode laser

    Science.gov (United States)

    Mcelroy, C. T.; Goldman, A.; Fogal, P. F.; Murcray, D. G.

    1990-01-01

    Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (0.0003/cm) solar spectra in the 9.6-micron ozone band. Observations have shown that a signal-to-noise ratio of 120:1 (about 30 percent of theoretical) for an integration time of 1/8 s can be achieved at a resolution of 0.0013 wave numbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that measured at the nearby NOAA ozone monitoring facility in Boulder, Colorado. Line positions for several ozone lines in the spectral region 996-997/cm are reported. Recent improvements have produced a signal-to-noise ratio of 95:1 (about 40 percent of theoretical) at 0.0003/cm and extended the range of wavelengths which can be observed.

  5. Response of grapevine leaves to plasmopara viticola infection by means of measurement of reflectance and fluorescence signals

    Czech Academy of Sciences Publication Activity Database

    Šebela, David; Olejníčková, Julie; Župčanová, A.; Sotolář, R.

    2012-01-01

    Roč. 27, č. 8 (2012), s. 229-237 ISSN 1211-8516 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0073 Institutional support: RVO:67179843 Keywords : Plasmopara viticola * downy mildew * grapevine * leaf tissue * susceptible varieties * chlorophyll fluorescence imaging * reflectance Subject RIV: GM - Food Processing

  6. Variations in chemical sexual signals of Psammodromus algirus lizards along an elevation gradient may reflect altitudinal variation in microclimatic conditions

    Science.gov (United States)

    Martín, José; Javier Zamora-Camacho, Francisco; Reguera, Senda; López, Pilar; Moreno-Rueda, Gregorio

    2017-04-01

    Chemical signals used in intraspecific communication are expected to evolve or to show phenotipic plasticity to maximize efficacy in the climatic conditions of a given environment. Elevational environmental gradients in mountains provide a good opportunity to test this hypothesis by examining variation in characteristics of signals in species found across different elevations with different climatic conditions. We analyzed by gas chromatography-mass spectrometry (GC-MS) the lipophilic fraction of the femoral gland secretions of male lizards Psammodromus algirus (Fam. Lacertidae) from six localities located along a 2200 m elevational gradient at Sierra Nevada Mountains (SE Spain). There was elevational clinal variation in climatic variables, number of femoral pores and in the relative proportions of some classes of compounds (i.e., ethyl esters of fatty acids, waxy esters, and aldehydes) but not others. We discuss how this variation would result in different physicochemical properties of the entire femoral secretion, which might help optimize the efficacy of chemical signals under the particular microclimatic conditions at each elevation.

  7. Moderate resolution spectrophotometry of high redshift quasars

    Science.gov (United States)

    Schneider, Donald P.; Schmidt, Maarten; Gunn, James E.

    1991-01-01

    A uniform set of photometry and high signal-to-noise moderate resolution spectroscopy of 33 quasars with redshifts larger than 3.1 is presented. The sample consists of 17 newly discovered quasars (two with redshifts in excess of 4.4) and 16 sources drawn from the literature. The objects in this sample have r magnitudes between 17.4 and 21.4; their luminosities range from -28.8 to -24.9. Three of the 33 objects are broad absorption line quasars. A number of possible high redshift damped Ly-alpha systems were found.

  8. Diffusion-weighted magnetic resonance imaging reflects activation of signal transducer and activator of transcription 3 during focal cerebral ischemia/reperfusion

    Directory of Open Access Journals (Sweden)

    Wen-juan Wu

    2017-01-01

    Full Text Available Signal transducer and activator of transcription (STAT is a unique protein family that binds to DNA, coupled with tyrosine phosphorylation signaling pathways, acting as a transcriptional regulator to mediate a variety of biological effects. Cerebral ischemia and reperfusion can activate STATs signaling pathway, but no studies have confirmed whether STAT activation can be verified by diffusion-weighted magnetic resonance imaging (DWI in rats after cerebral ischemia/reperfusion. Here, we established a rat model of focal cerebral ischemia injury using the modified Longa method. DWI revealed hyperintensity in parts of the left hemisphere before reperfusion and a low apparent diffusion coefficient. STAT3 protein expression showed no significant change after reperfusion, but phosphorylated STAT3 expression began to increase after 30 minutes of reperfusion and peaked at 24 hours. Pearson correlation analysis showed that STAT3 activation was correlated positively with the relative apparent diffusion coefficient and negatively with the DWI abnormal signal area. These results indicate that DWI is a reliable representation of the infarct area and reflects STAT phosphorylation in rat brain following focal cerebral ischemia/reperfusion.

  9. PRECISION SPECTROPHOTOMETRY AT THE LEVEL OF 0.1%

    International Nuclear Information System (INIS)

    Yan Renbin

    2011-01-01

    Accurate relative spectrophotometry is critical for many science applications. Small wavelength-scale residuals in the flux calibration can significantly impact the measurements of weak emission and absorption features in the spectra. Using Sloan Digital Sky Survey data, we demonstrate that the average spectra of carefully selected red-sequence galaxies can be used as a spectroscopic standard to improve the relative spectrophotometry precision to 0.1% on small wavelength scales (from a few to hundreds of Angstroms). We achieve this precision by comparing stacked spectra across tiny redshift intervals. The redshift intervals must be small enough that any systematic stellar population evolution is minimized and is less than the spectrophotometric uncertainty. This purely empirical technique does not require any theoretical knowledge of true galaxy spectra. It can be applied to all large spectroscopic galaxy redshift surveys that sample a large number of galaxies in a uniform population.

  10. Two-dimensional spectrophotometry of planetary nebulae by CCD imaging

    International Nuclear Information System (INIS)

    Jacoby, G.H.; Africano, J.L.; Quigley, R.J.; Western Washington Univ., Bellingham, WA)

    1987-01-01

    The spatial distribution of the electron temperature and density and the ionic abundances of O(+), O(2+), N(+), and S(+) have been derived from CCD images of the planetary nebulae NGC 40 and NGC 6826 taken in the important emission lines of forbidden O II, forbidden O III, H-beta, forbidden N II, and forbidden S II. The steps required in the derivation of the absolute fluxes, line, ratios, and ionic abundances are outlined and then discussed in greater detail. The results show that the CCD imaging technique for two-dimensional spectrophotometry can effectively compete with classical spectrophotometry, providing the added benefits of complete spatial coverage at seeing-disk spatial resolution. The multiplexing in the spatial dimension, however, results in a loss of spectral information, since only one emission line is observed at any one time. 37 references

  11. Spectrophotometry of cerebrospinal fluid in subacute and chronic subdural haematomas

    Science.gov (United States)

    Kjellin, K. G.; Steiner, L.

    1974-01-01

    Spectrophotometric examinations were performed on cerebrospinal and subdural fluids in subacute (five patients) and chronic (20 patients) subdural haematomas, with special reference to the diagnostic aid of CSF spectrophotometry. Spectrophotometric xanthochromia of haemorrhagic origin was found in all CSFs examined, while definite visible xanthochromia was observed in only 28% and the CSF was judged as colourless in 52% of those cases. Characteristic bleeding patterns were found spectrophotometrically in all the 20 CSFs examined within 24 hours after lumbar puncture, haematoma patterns being detected in 90-95% of the cases. In many cases the electrophoretically separated protein fractions of CSF and subdural fluids were spectrophotometrically examined. In conclusion, CSF spectrophotometry is a simple, fast, and extremely sensitive method, which in our opinion should be used routinely in the diagnosis of suspected subdural haematomas, if lumbar puncture is not contraindicated. PMID:4140892

  12. Uranium determination by UV-Vis spectrophotometry in organic matrix

    International Nuclear Information System (INIS)

    Iwaki, Leonardo E.O.; Silva, Ieda S.; Oliveira, Luis C.

    2013-01-01

    Concentrations of uranium in the process samples provide essential information required for nuclear process monitoring. A large number of techniques have been developed to allow uranium determination, but each technique possesses some advantages and disadvantages and cannot be applied without difficulty to all samples. The ultraviolet visible spectrophotometry (UV-Vis) is widely method used in analytical industrial processes due to its simplicity, rapidity, low costs, low generation of analytical waste, easy calibration and operation. In this study, we describe a simple and fast quantification method to determination of a high amount of uranium in organic phase (TBP/kerosene) using UV-Vis spectrophotometry. The process sample was analyzed in UV-Vis and compared with inductively coupled plasma optical emission spectrometry (ICP OES) showing similar results in both methods. The statistical tests (Student-t and Fischer) showed that the both techniques they are equivalent. (author)

  13. Dynamic range broadening for photomultipliers in kinetic spectrophotometry

    International Nuclear Information System (INIS)

    Rumas, V.K.

    1983-01-01

    The circuit of switching on a photomultiplier with prestage modulation developed for kinetic spectrophotometry purposes is described. Distinguishing features of the scheme are wide range of control pulse duration (40 nc - 2.5 mc) and direct transistor photostart by laser light pulse. In the case of PM prestage modulation for the second dynode modulation depth attains 400 while PM opening time constitutes 40 nc

  14. Determination of gadolinium by the method of derivative spectrophotometry

    International Nuclear Information System (INIS)

    Aleksandrova, N.N.; Mishchenko, V.T.; Poluehktov, N.S.; Mukomel', V.L.

    1988-01-01

    Technique for gadolinium determination at the presence of interfering rare earth elements, which is based on the derivative spectrophotometry method, is suggested. The technique is of increased selectivity and allows to determine gadolinium in the mixtures with elements, which presence in solution makes impossible to determine gadolinium directly. At binary mixtures analysis Sr relative standard deviation does not exceed 0.03, while at the analysis of more complex mixtures Sr increases up to 0.06

  15. Spectrophotometry-based detection of carbapenemase producers among Enterobacteriaceae.

    Science.gov (United States)

    Bernabeu, Sandrine; Poirel, Laurent; Nordmann, Patrice

    2012-09-01

    Carbapenem-hydrolyzing ß-lactamases are the most powerful ß-lactamases being able to hydrolyse almost all ß-lactams. They are mostly of the KPC, VIM, IMP, NDM, and OXA-48 type. A spectrophotometry technique based on analysis of the imipenem hydrolysis has been developed that differentiated carbapenemase- from noncarbapenemase producers. This inexpensive technique adapted to screening of carbapenemase producers may be implemented in any reference laboratory worldwide. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. 8-13μm spectrophotometry of galaxies

    International Nuclear Information System (INIS)

    Roche, P.F.; Aitken, D.K.; Whitmore, B.

    1983-01-01

    Spectrophotometry at 8-13 μm of Mkn 231 confirms that the 10 μm minimum is due to large columns of silicate dust in the line-of-sight to the nucleus. Fits to the detailed spectral shape demonstrate that the cool absorbing grains are at the emission (z=0.042) rather than the absorption (z approx.= 0.025) redshift and are located within the nuclear region. (author)

  17. Specific Features of the Hypothalamic Leptin Signaling Response to Cold Exposure Are Reflected in Peripheral Blood Mononuclear Cells in Rats and Ferrets

    Directory of Open Access Journals (Sweden)

    Bàrbara Reynés

    2017-08-01

    Full Text Available Objectives: Cold exposure induces hyperphagia to counteract fat loss related to lipid mobilization and thermogenic activation. The aim of this study was investigate on the molecular mechanisms involved in cold-induced compensatory hyperphagia.Methods: We analyzed the effect of cold exposure on gene expression of orexigenic and anorexigenic peptides, and of leptin signaling-related genes in the hypothalamus of rats at different ages (1, 2, 4, and 6 months, as well as in ferrets. We also evaluated the potential of peripheral blood mononuclear cells to reflect hypothalamic molecular responses.Results: As expected, cold exposure induced hypoleptinemia in rats, which could be responsible for the increased ratio of orexigenic/anorexigenic peptides gene expression in the hypothalamus, mainly due to decreased anorexigenic gene expression, especially in young animals. In ferrets, which resemble humans more closely, cold exposure induced greater changes in hypothalamic mRNA levels of orexigenic genes. Despite the key role of leptin in food intake control, the effect of cold exposure on the expression of key hypothalamic leptin signaling cascade genes is not clear. In our study, cold exposure seemed to affect leptin signaling in 4-month-old rats (increased Socs3 and Lepr expression, likely associated with the smaller-increase in food intake and decreased body weight observed at this particular age. Similarly, cold exposed ferrets showed greater hypothalamic Socs3 and Stat3 gene expression. Interestingly, peripheral blood mononuclear cells (PBMC mimicked the hypothalamic increase in Lepr and Socs3 observed in 4-month-old rats, and the increased Socs3 mRNA expression observed in ferrets in response to cold exposure.Conclusions: The most outstanding result of our study is that PBMC reflected the specific modulation of leptin signaling observed in both animal models, rats and ferrets, which points forwards PBMC as easily obtainable biological material to be

  18. Available number of multiplexed holograms based on signal-to-noise ratio analysis in reflection-type holographic memory using three-dimensional speckle-shift multiplexing.

    Science.gov (United States)

    Nishizaki, Tatsuya; Matoba, Osamu; Nitta, Kouichi

    2014-09-01

    The recording properties of three-dimensional speckle-shift multiplexing in reflection-type holographic memory are analyzed numerically. Three-dimensional recording can increase the number of multiplexed holograms by suppressing the cross-talk noise from adjacent holograms by using depth-direction multiplexing rather than in-plane multiplexing. Numerical results indicate that the number of multiplexed holograms in three-layer recording can be increased by 1.44 times as large as that of a single-layer recording when an acceptable signal-to-noise ratio is set to be 2 when NA=0.43 and the thickness of the recording medium is 0.5 mm.

  19. Computer tomography of the brain and spectrophotometry of the CSF in cerebral concussion and contusion

    International Nuclear Information System (INIS)

    Bergvall, U.; Kjellin, K.G.; Levander, B.; Svendsen, P.; Soederstroem, C.E.

    1978-01-01

    Computer tomography (CT) and spectrophotometry of CSF were performed in 30 patients with the clinical diagnosis of cerebral concussion or contusion. The patients with concussion all had normal CT-findings. Spectrophotometry of CSF was sometimes positive for cerebral contusion with normal CT-findings, but the two methods were complementary so that the extent of the lesion was determined by CT and spectrophotometry of CSF indicated the cause. (Auth.)

  20. Evaluation of light scattering properties and chromophore concentrations in skin tissue based on diffuse reflectance signals at isosbestic wavelengths of hemoglobin

    Science.gov (United States)

    Yokokawa, Takumi; Nishidate, Izumi

    2016-04-01

    We investigate a method to evaluate light-scattering properties and chromophore concentrations in human skin tissue through diffuse reflectance spectroscopy using the reflectance signals acquired at isosbestic wavelengths of hemoglobin (420, 450, 500, and 585 nm). In the proposed method, Monte Carlo simulation-based empirical formulas are used to specify the scattering parameters of skin tissue, such as the scattering amplitude a and the scattering power b, as well as the concentration of melanin C m and the total blood concentration C tb. The use of isosbestic wavelengths of hemoglobin enables the values of C m, C tb, a, and b to be estimated independently of the oxygenation of hemoglobin. The spectrum of the reduced scattering coefficient is reconstructed from the scattering parameters. Experiments using in vivo human skin tissues were performed to confirm the feasibility of the proposed method for evaluating the changes in scattering properties and chromophore concentrations in skin tissue. The experimental results revealed that light scattering is significantly reduced by the application of a glycerol solution, which indicates an optical clearing effect due to osmotic dehydration and the matching of the refractive indices of scatterers in the epidermis.

  1. Ultraviolet spectrophotometry from Gemini 11 of stars in Orion

    International Nuclear Information System (INIS)

    Morgan, T.H.; Spear, G.G.; Kondo, Y.; Henize, K.G.

    1975-01-01

    Ultraviolet spectrophotometry in the wavelength region 2600--3600 A is reported for the bright early-type stars β, eta, γ, delta, iota, epsilon, sigma, xi, and kappa Ori. The results are in good agreement with other observations, and with the possible exception of the supergiants, are in good agreement with recent line-blanketed model atmospheres. There is evidence that the supergiants possess a small ultraviolet deficiency shortward of 3000 A relative to main-sequence stars of similar spectral type. The most extreme example of this phenomenon is the star kappa Ori

  2. Method for rapidly determining a pulp kappa number using spectrophotometry

    Science.gov (United States)

    Chai, Xin-Sheng; Zhu, Jun Yong

    2002-01-01

    A system and method for rapidly determining the pulp kappa number through direct measurement of the potassium permanganate concentration in a pulp-permanganate solution using spectrophotometry. Specifically, the present invention uses strong acidification to carry out the pulp-permanganate oxidation reaction in the pulp-permanganate solution to prevent the precipitation of manganese dioxide (MnO.sub.2). Consequently, spectral interference from the precipitated MnO.sub.2 is eliminated and the oxidation reaction becomes dominant. The spectral intensity of the oxidation reaction is then analyzed to determine the pulp kappa number.

  3. Identification and spectrophotometry of faint southern radio galaxies

    International Nuclear Information System (INIS)

    Spinrad, H.; Kron, R.G.; Hunstead, R.W.

    1980-01-01

    We have observed a mixed sample of southern radio sources, identified on the Palomar sky survey or on previous direct plates taken with medium-aperture reflectors. At CIO we obtained a few deep 4m photographs and SIT spectrophotometry for redshift and continuum-color measurement. Almost all our sources were faint galaxies; the largest redshift measured was for 3C 275, with z=0.480. The ultraviolet continuum of PKS 0400--643, a ''thermal'' galaxy with z=0.476, closely resembles that of 3C 295 and shows some color evolution in U--B compared to nearby giant ellipticals

  4. On a variant of the first derivative technique in spectrophotometry

    International Nuclear Information System (INIS)

    Kvaratskheli, Yu.K.; Pchelkin, V.A.; Demin, Yu.V.; Kukushkin, G.R.

    1981-01-01

    A variant of the first derivative technique in spectrophotometry is suggested which is based on continuous sinusoidal sweep of the wavelength within a narrow spectral region. A spectrophotometer has been designed which records the first derivative (dA/dlambda). A method has been developed of determining uranium (6) with arsenazo 3 in the presence of 20 times its amounts of zirconium thorium or iron (3). The method can be used for spectrophotometric determination of some other elements with different reagents, particularly in the analysis of elements with overlapped absorption spectra [ru

  5. Spectrophotometry with optical fibers applied to nuclear product processing

    International Nuclear Information System (INIS)

    Boisde, G.; Perez, J.J.; Velluet, M.T.; Jeunhomme, L.B.

    1988-01-01

    Absorption spectrophotometry is widely used in laboratories for composition analysis and quality control of chemical processes. Using optical fibers for transmitting the light between the instrument and the process line allows to improve the safety and productivity of chemical processes, thanks to real time measurements. Such applications have been developed since 1975 in CEA for the monitoring of nuclear products. This has led to the development of fibers, measurement cells, and optical feedthrough sustaining high radiation doses, of fiber/spectrophotometer couplers, and finally of a photodiode array spectrophotometer optimized for being used together with optical fibers [fr

  6. Analysis of impurities in silver matrix by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Hussain, R.; Ishaque, M.; Mohammad, D.

    1999-01-01

    A procedure for the analysis of aluminium, chromium, copper, lead, mercury, nickel and zinc mainly using flame lens atomic absorption spectrophotometry has been described. The results depict that the presence of silver does not introduce any significant interference, when standards are prepared in matching silver matrix solutions. The calibration curves obey the straight-line equations passing through the origin. Thus the separation of silver matrix from the analyte solutions is not necessary. The method has successfully been applied for the analysis of silver foils, wires, battery grade silver oxides and silver nitrate samples containing analyte elements in the concentration range 2 to 40 ppm. (author)

  7. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  8. Reflecting reflection in supervision

    DEFF Research Database (Denmark)

    Lystbæk, Christian Tang

    associated with reflection and an exploration of alternative conceptions that view reflection within the context of settings which have a more group- and team-based orientation. Drawing on an action research project on health care supervision, the paper questions whether we should reject earlier views...... of reflection, rehabilitate them in order to capture broader connotations or move to new ways of regarding reflection that are more in keeping with not only reflective but also emotive, normative and formative views on supervision. The paper presents a critical perspective on supervision that challenge...... the current reflective paradigm I supervision and relate this to emotive, normative and formative views supervision. The paper is relevant for Nordic educational research into the supervision and guidance...

  9. Application of wavelet and Fuorier transforms as powerful alternatives for derivative spectrophotometry in analysis of binary mixtures: A comparative study

    Science.gov (United States)

    Hassan, Said A.; Abdel-Gawad, Sherif A.

    2018-02-01

    Two signal processing methods, namely, Continuous Wavelet Transform (CWT) and the second was Discrete Fourier Transform (DFT) were introduced as alternatives to the classical Derivative Spectrophotometry (DS) in analysis of binary mixtures. To show the advantages of these methods, a comparative study was performed on a binary mixture of Naltrexone (NTX) and Bupropion (BUP). The methods were compared by analyzing laboratory prepared mixtures of the two drugs. By comparing performance of the three methods, it was proved that CWT and DFT methods are more efficient and advantageous in analysis of mixtures with overlapped spectra than DS. The three signal processing methods were adopted for the quantification of NTX and BUP in pure and tablet forms. The adopted methods were validated according to the ICH guideline where accuracy, precision and specificity were found to be within appropriate limits.

  10. Spectrophotometry of comets Giacobini-Zinner and Halley

    International Nuclear Information System (INIS)

    Tegler, S.C.; O'dell, C.R.

    1987-01-01

    Optical window spectrophotometry was performed on comets Giacobini-Zinner and Halley over the interval 300-1000 nm. Band and band-sequence fluxes were obtained for the brightest features of OH, CN, NH, and C2, special care having been given to determinations of extinction, instrumental sensitivities, and corrections for Fraunhofer lines. C2 Swan band-sequence flux ratios were determined with unprecedented accuracy and compared with the predictions of the detailed equilibrium models of Krishna Swamy et al. (1977, 1979, 1981, and 1987). It is found that these band sequences do not agree with the predictions, which calls into question the assumptions made in deriving the model, namely resonance fluorescence statistical equilibrium. Suggestions are made as to how to resolve this discrepancy. 16 references

  11. Determination of micro amounts of praseodymium by analogue derivative spectrophotometry

    International Nuclear Information System (INIS)

    Ishii, Hajime; Satoh, Katsuhiko.

    1986-01-01

    Derivative spectrophotometry using the analogue differentiation circuit was applied to the determination of praseodymium at the ppm level. By the proposed method, in which the second or fourth derivative spectrum of the characteristic absorption band of praseodymium(III) at 444 nm is measured, as little as 3 ppm of praseodymium can be determined directly and easily even in the presence of large amounts of other rare earths without any prior separation. Interferences from neodymium, samarium, dysprosium, holmium and erbium ions which have characteristic absorption bands around 444 nm can easily be removed by utilizing the isosbestic point in the derivative spectra of praseodymium(III) and the interfering rare earth(III). (author)

  12. Spectrophotometry of comets Giacobini-Zinner and Halley

    Science.gov (United States)

    Tegler, Stephen C.; O'Dell, C. R.

    1987-01-01

    Optical window spectrophotometry was performed on comets Giacobini-Zinner and Halley over the interval 300-1000 nm. Band and band-sequence fluxes were obtained for the brightest features of OH, CN, NH, and C2, special care having been given to determinations of extinction, instrumental sensitivities, and corrections for Fraunhofer lines. C2 Swan band-sequence flux ratios were determined with unprecedented accuracy and compared with the predictions of the detailed equilibrium models of Krishna Swamy et al. (1977, 1979, 1981, and 1987). It is found that these band sequences do not agree with the predictions, which calls into question the assumptions made in deriving the model, namely resonance fluorescence statistical equilibrium. Suggestions are made as to how to resolve this discrepancy.

  13. Airborne spectrophotometry of Comet Halley from 5 to 9 microns

    Science.gov (United States)

    Campins, H.; Bregman, J. D.; Witteborn, F. C.; Wooden, D. H.; Rank, D. M.; Cohen, M.; Allamandola, Louis J.; Tielens, Alexander G. G. M.

    1986-01-01

    Spectrophotometry from 5 to 9 microns (resolution = 0.02) of comet Halley was obtained from the Kuiper Airborne Observatory on 1985 Dec. 12.1 and 1986 April 8.6 and 10.5 UT. Two spectral features are apparent in all the observations, one from 5.24 to 5.6 microns, and the silicate emission feature which has an onset between 7 and 8 microns. There is no evidence for the 7.5 microns feature observed by the Vega 1 spacecraft; the large difference between the areal coverage viewed from the spacecraft and the airplane may explain the discrepancy. Color temperatures significantly higher than a blackbody indicate that small particles are abundant in the coma. Significant spatial and temporal variations in the spectrum show trends similar to those observed from the ground.

  14. Emission flame spectrophotometry of chromium, cobalt, nickel trace amounts

    International Nuclear Information System (INIS)

    Prudnikov, Y.D.; Shapkina, Y.S.

    1976-01-01

    Chromium, cobalt, and nickel were determined in a flame spectrophotometer with a dual diffraction monochromator, DFS-12, in a high-temperature nitrogen-acetylene flame. The effect of ionization and the elements in the oxidizing flame was small. The lower limit of detection for the three elements is 1x10 -2 to 1 x10 -3 μg/ml, and the high selectivity of the analysis permits determining down to 10 -4 % Cr and Ni and to 10 -3 % Co. These elements may be determined in rocks and minerals from solutions prepared for analysis for alkali and alkali-earth elements. The possibilities of emission flame spectrophotometry are as great as those of atomic-absorption analysis, and it may be used for determining Cr, Co, and Ni in rocks and minerals, especially pure substances, metals, and other materials

  15. Determination of Lead in Blood by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramér, Kim

    1968-01-01

    Lead in blood was determined by atomic absorption spectrophotometry, using a wet ashing procedure and a procedure in which the proteins were precipitated with trichloroacetic acid. In both methods the lead was extracted into isobutylmethylketone before measurement, using ammonium pyrrolidine dithiocarbamate as chelator. The simpler precipitation procedure was shown to give results identical with those obtained with the ashing technique. In addition, blood specimens were examined by the precipitation method and by spectral analysis, which method includes wet ashing of the samples, with good agreement. All analyses were done on blood samples from `normal' persons or from lead-exposed workers, and no additions of inorganic lead were made. The relatively simple protein precipitation technique gave accurate results and is suitable for the large-scale control of lead-exposed workers. PMID:5663425

  16. Study of Biological Pigments by Single Specimen Derivative Spectrophotometry

    Science.gov (United States)

    Goldstein, Jack M.

    1970-01-01

    The single specimen derivative (SSD) method provides an absolute absorption spectrum of a substance in the absence of a suitable reference. Both a reference and a measuring monochromatic beam pass through a single sample, and the specimen itself acts as its own reference. The two monochromatic beams maintain a fixed wavelength difference upon scanning, and the difference in absorbance of the two beams is determined. Thus, the resulting spectrum represents the first derivative of the conventional type absorption spectrum. Tissues and cell fractions have been examined at room and liquid N2 temperature and chromophoric molecules such as the mitochondrial cytochromes and blood pigments have been detectable in low concentrations. In the case of isolated cellular components, the observed effects of substrates and inhibitors confirm similar studies by conventional spectrophotometry. The extension of the SSD concept to the microscopic level has permitted the study of the tissue compartmentalization and function of cytochromes and other pigments within layered tissue. PMID:4392452

  17. Quantitation of heparosan with heparin lyase III and spectrophotometry.

    Science.gov (United States)

    Huang, Haichan; Zhao, Yingying; Lv, Shencong; Zhong, Weihong; Zhang, Fuming; Linhardt, Robert J

    2014-02-15

    Heparosan is Escherichia coli K5 capsule polysaccharide, which is the key precursor for preparing bioengineered heparin. A rapid and effective quantitative method for detecting heparosan is important in the large-scale production of heparosan. Heparin lyase III (Hep III) effectively catalyzes the heparosan depolymerization, forming unsaturated disaccharides that are measurable using a spectrophotometer at 232 nm. We report a new method for the quantitative detection of heparosan with heparin lyase III and spectrophotometry that is safer and more specific than the traditional carbazole assay. In an optimized detection system, heparosan at a minimum concentration of 0.60 g/L in fermentation broth can be detected. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Direct imaging and spectrophotometry of Comet P/Tempel 2

    International Nuclear Information System (INIS)

    Boehnhardt, H.; Beisser, K.; Vanysek, V.; Mueller, B.E.A.; Weiss, M.

    1990-01-01

    Both direct imaging and spectrophotometry of Comet P/Tempel 2 during May-November 1988 have led to a nuclear diameter determination of the order of about 10 km. Sekanina's (1987) spin-vector model for this comet is judged capable of qualitatively accounting for both the visual light curve of the comet during this period, which exhibited a steep increase perihelion despite the normal, moderate-decrease perihelion, and an asymmetric extension of the fanlike coma in the solar direction. The late activity onset, the possible constant visual brightness immediately afterward, and the deviation of the fan axis orientation from the predicted value in May 1988, may all furnish additional constraints for P/Tempel 2 nucleus modeling. 24 refs

  19. Determination of serum albumin with tribromoarsenazo by spectrophotometry

    Directory of Open Access Journals (Sweden)

    Qing-Zhou Zhai

    2007-08-01

    Full Text Available The reaction of tribromoarsenazo(TB-ASA with serum albumin in the presence of emulgent OP was studied by spectrophotometry. In a Britton-Robinson buffer solution at pH 2.9, tribromoarsenazo and bovine serum albumin can immediately form a red compound in the presence of emulgent OP with a maximum absorption wavelength at 354 nm. The presence of emulgent OP can increase the reaction sensitivity and the compound stability. The molar absorptivity of the compound is ε354 nm = 6.13 x 105 M-1•cm-1. Beer's law is obeyed over the range of 5.0-75.0 mg•L-1 for bovine serum albumin. The present method was applied to the determination of the total proteins in human serums with satisfactory results.

  20. On-line photolithography modeling using spectrophotometry and Prolith/2

    Science.gov (United States)

    Engstrom, Herbert L.; Beacham, Jeanne E.

    1994-05-01

    Spectrophotometry has been applied to optimizing photolithography processes in semiconductor manufacturing. For many years thin film measurement systems have been used in manufacturing for controlling film deposition processes. The combination of film thickness mapping with photolithography modeling has expanded the applications of this technology. Experimental measurements of dose-to-clear, the minimum light exposure dose required to fully develop a photoresist, are described. It is shown how dose-to-clear and photoresist contrast may be determined rapidly and conveniently from measurements of a dose exposure matrix on a monitor wafer. Such experimental measurements may underestimate the dose-to- clear because of thickness variations of the photoresist and underlying layers on the product wafer. Online modeling of the photolithographic process together with film thickness maps of the entire wafer can overcome this problem. Such modeling also provides maps of dose-to- clear and resist linewidth that can be used to estimate and optimize yield.

  1. Discovery and spectrophotometry of high-redshift quasars

    International Nuclear Information System (INIS)

    MacAlpine, G.M.; Feldman, F.R.

    1982-01-01

    We report on the discovery and spectrophotometry of 30 new high-redshift quasars, which were detected using the Curtis Schmidt technique. We also discuss new follow-up spectrophotometry for 23 quasar candidates from University of Michigan Lists I--IV. Our program sample contains eight quasars with z>3, at least five objects exhibiting broad absorption troughs, and a pair of quasars which are 1' apart on the sky and nearly identical in redshift, at z near 2.13. The redshift distribution for the majority of quasars in UM List IV suggests that most of the single-line quasar candidates in the UM List have low to moderate redshifts, with the reported line often being Mg II lambda2798 or C III] lambda1909. For 17 high-redshift quasars where lambda912 at the emission-line redshift could be examined, we did not find any definite Lyman limit cutoffs. Although three objects show a decline of the continuum within 100 A of lambda912, we do not believe them to be unambiguous examples for emission-line clouds situated in the line of sight. When our O I lambda1304 measurements are combined with the data of others to yield a composite spectrum, we obtain O I lambda1304/lambda8446 = 1.35. This suggests reddening with E/sub B/-Vroughly-equal0.23. Finally, our data exhibit a correlation between Lyα emission line velocity widths and redshift. The higher z quasars in the sample tend to have narrower lines, due, at least in part, to bias in the detection technique

  2. Spectrophotometry of Artemisia tridentata to quantitatively determine subspecies

    Science.gov (United States)

    Richardson, Bryce; Boyd, Alicia; Tobiasson, Tanner; Germino, Matthew

    2018-01-01

    Ecological restoration is predicated on our abilities to discern plant taxa. Taxonomic identification is a first step in ensuring that plants are appropriately adapted to the site. An example of the need to identify taxonomic differences comes from big sagebrush (Artemisia tridentata). This species is composed of three predominant subspecies occupying distinct environmental niches, but overlap and hybridization are common in ecotones. Restoration of A. tridentata largely occurs using wildland collected seed, but there is uncertainty in the identification of subspecies or mix of subspecies from seed collections. Laboratory techniques that can determine subspecies composition would be desirable to ensure that subspecies match the restoration site environment. In this study, we use spectrophotometry to quantify chemical differences in the water-soluble compound, coumarin. Ultraviolet (UV) absorbance of A. tridentata subsp. vaseyana showed distinct differences among A.t. tridentata and wyomingensis. No UV absorbance differences were detected between A.t. tridentata and wyomingensis. Analyses of samples from > 600 plants growing in two common gardens showed that UV absorbance was unaffected by environment. Moreover, plant tissues (leaves and seed chaff) explained only a small amount of the variance. UV fluorescence of water-eluted plant tissue has been used for many years to indicate A.t. vaseyana; however, interpretation has been subjective. Use of spectrophotometry to acquire UV absorbance provides empirical results that can be used in seed testing laboratories using the seed chaff present with the seed to certify A. tridentata subspecies composition. On the basis of our methods, UV absorbance values 3.1 would indicate either A.t. tridentata or wyomingensis. UV absorbance values between 2.7 and 3.1 would indicate a mixture of A.t. vaseyana and the other two subspecies.

  3. Simple and rapid quantification of total carotenoids in lyophilized apricots (prunus armeniaca L.) by means of reflectance colorimetry and photoacoustic spectrometry spectroscopy

    NARCIS (Netherlands)

    Doka, O.; Ficzek, G.; Luterotti, S.; Bicanic, D.D.; Spruijt, R.B.; Buijnsters, J.; Vegvari, G.

    2013-01-01

    Photoacoustic spectroscopy (PAS) and reflectance colorimetry are suggested as new tools for the analysis of total carotenoids in lyophilized apricot powders. The data obtained by these two techniques from seven apricot cultivars were compared to those acquired by spectrophotometry and

  4. Determination of piroxicam in pharmaceutical preparations by ultraviolet direct spectrophotometry, ultraviolet difference spectrophotometry and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hackmann, E.R.M.; Santos Gianotto, E.A. dos; Miritello Santoro, M.I.R. (Universidade de Sao Paulo (Brazil))

    1993-02-01

    Piroxicam in pharmaceutical preparations (capsules (C), tablets (T), oral drops (OD), suppositories (S) and simulated sample (SS)) was determined by UV direct spectrophotometry (UVS) at 333 nm, by UV difference spectrophotometry (UVDS) at 327 nm, and in C and T, by high performance liquid chromatography (HPLC). For UVS, Beer's law was obeyed in the range 3.0-8.5 [mu]g/mL. The coefficient of correlation (CC), absolute precision (AP) and relative precision (RP) were 0.9999, 0.02 and 0.33%, respectively. The coefficient of variation (CV) for C, T, OD, S and SS were 0.48%, 0.35%, 0.48% and 0.19%, respectively. The recovery average (RA) was 100.22%. For UVDS, Beer's law was obeyed in the range 5.0-15.0 [mu]g/mL. The CC, AP and RP were respectively 0.9999, 0.05 and 0.47%. The CV for C, T, OD, S and SS were 0.64%, 0.84%, 0.62%, 0.54% and 0.15%, respectively. The RA was 99.02%. In HPLC determination, a LiChrospher[reg sign] 100 RP-18 (5 [mu]m) in LiChroCART[reg sign] 125-4 column at ambient temperature with a mobile phase consisting of methanol: (buffer solution citric acid-dibasic sodium phosphate pH 3.0) (55:45) and UV detection at 254 nm enabled the determination of piroxicam in C and T. The response peak area versus concentration presented linearity in the range 10.0-100.0 [mu]g/mL. The CC, AP and RP were 0.9997, 0.45 and 0.90%, respectively. The CV was 0.51%-0.82% and the RA, 97.13%. 14 refs., 1 fig., 5 tabs.

  5. Partitioning of organophosphorus pesticides into phosphatidylcholine small unilamellar vesicles studied by second-derivative spectrophotometry.

    Science.gov (United States)

    Takegami, Shigehiko; Kitamura, Keisuke; Ohsugi, Mayuko; Ito, Aya; Kitade, Tatsuya

    2015-06-15

    In order to quantitatively examine the lipophilicity of the widely used organophosphorus pesticides (OPs) chlorfenvinphos (CFVP), chlorpyrifos-methyl (CPFM), diazinon (DZN), fenitrothion (FNT), fenthion (FT), isofenphos (IFP), profenofos (PFF) and pyraclofos (PCF), their partition coefficient (Kp) values between phosphatidylcholine (PC) small unilamellar vesicles (SUVs) and water (liposome-water system) were determined by second-derivative spectrophotometry. The second-derivative spectra of these OPs in the presence of PC SUV showed a bathochromic shift according to the increase in PC concentration and distinct derivative isosbestic points, demonstrating the complete elimination of the residual background signal effects that were observed in the absorption spectra. The Kp values were calculated from the second-derivative intensity change induced by addition of PC SUV and obtained with a good precision of R.S.D. below 10%. The Kp values were in the order of CPFM>FT>PFF>PCF>IFP>CFVP>FNT⩾DZN and did not show a linear correlation relationship with the reported partition coefficients obtained using an n-octanol-water system (R(2)=0.530). Also, the results quantitatively clarified the effect of chemical-group substitution in OPs on their lipophilicity. Since the partition coefficient for the liposome-water system is more effective for modeling the quantitative structure-activity relationship than that for the n-octanol-water system, the obtained results are toxicologically important for estimating the accumulation of these OPs in human cell membranes. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Feasibility of spectro-photometry in X-rays (SPHINX) from the moon

    Science.gov (United States)

    Sarkar, Ritabrata; Chakrabarti, Sandip Kumar

    2010-08-01

    Doing space Astronomy on lunar surface has several advantages. We present here feasibility of an All Sky Monitoring Payload for Spectro-photometry in X-rays (SPHINX) which can be placed on a lander on the moon or in a space craft orbiting around the moon. The Si-PIN photo-diodes and CdTe crystals are used to detect solar flares, bright gamma bursts, soft gamma-ray repeaters from space and also X-ray fluorescence (XRF) from lunar surface. We present the complete Geant4 simulation to study the feasibility of such an instrument in presence of Cosmic Diffused X-Ray Background (CDXRB). We find that the signal to noise ratio is sufficient for moderate to bright GRBs (above 5 keV), for the quiet sun (up to 100 keV), solar flares, soft gamma-ray repeaters, X-ray Fluorescence (XRF) of lunar surface etc. This is a low-cost system which is capable of performing multiple tasks while stationed at the natural satellite of our planet.

  7. Improving the submicro determination of vanadium in natural water using primary-secondary wavelength spectrophotometry

    International Nuclear Information System (INIS)

    Khongven Gao

    1999-01-01

    In acidic solution and in the presence of ammonium persulfate, the conventional reaction of vanadium(5) with gallic acid to form an orange complex has been used for the improvement of the determination of trace amounts of vanadium in water by the updated method named primary-secondary wavelength spectrophotometry. The results show that the analytical precision and accuracy were improved and gave higher determination sensitivity than ordinary spectrophotometry. The relative standard deviations were less than 5.6 % [ru

  8. H II region in NGC 6744: Spectrophotometry and chemical abundances

    International Nuclear Information System (INIS)

    Talent, D.L.

    1982-01-01

    Spectrophotometry of emission lines in the lambdalambda3700--6800 spectral range is presented for An H II region in an outer arm of NGC6744, a southern hemisphere galaxy of type SAB(r)bc II. The electron temperature, derived from the [O III] lines and assuming N/sub e/ = 100 cm -3 , was found to be 9,630 +- 450 K. Ionic abundances, derived in the usual fashion from the measured line strengths, were corrected to total relative number abundances by application of the standard ionization correction factor (ICF) scheme and by comparison to models. The derived abundances, relative to log Hequivalent12.00, are log He = 10.96 +- 0.06, log N = 7.34 +- 0.26, log O log O = 8.44 +- 0.10, log Ne = 7.80 +- 0.16, and log S = 6.75 +- 0.28. The NGC 6744 H II region abundances, and various ratios, are compared to similar data for H II regions in the SMC, LMC, and the Perseus arm of the Galaxy,. From the comparison it is suggested that the histories of nucleosynthesis in the outer regions of NGC 6744 and the Galaxy could have been quite similar

  9. The role of spectrophotometry in the diagnosis of melanoma

    Science.gov (United States)

    2010-01-01

    Background Spectrophotometry (SPT) could represent a promising technique for the diagnosis of cutaneous melanoma (CM) at earlier stages of the disease. Starting from our experience, we further assessed the role of SPT in CM early detection. Methods During a health campaign for malignant melanoma at National Cancer Institute of Naples, we identified a subset of 54 lesions to be addressed to surgical excision and histological examination. Before surgery, all patients were investigated by clinical and epiluminescence microscopy (ELM) screenings; selected lesions underwent spectrophotometer analysis. For SPT, we used a video spectrophotometer imaging system (Spectroshade® MHT S.p.A., Verona, Italy). Results Among the 54 patients harbouring cutaneous pigmented lesions, we performed comparison between results from the SPT screening and the histological diagnoses as well as evaluation of both sensitivity and specificity in detecting CM using either SPT or conventional approaches. For all pigmented lesions, agreement between histology and SPT classification was 57.4%. The sensitivity and specificity of SPT in detecting melanoma were 66.6% and 76.2%, respectively. Conclusions Although SPT is still considered as a valuable diagnostic tool for CM, its low accuracy, sensitivity, and specificity represent the main hamper for the introduction of such a methodology in clinical practice. Dermoscopy remains the best diagnostic tool for the preoperative diagnosis of pigmented skin lesions. PMID:20707921

  10. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  11. [Wavelength Selection in Hemolytic Evaluation Systems with Spectrophotometry Detection].

    Science.gov (United States)

    Zhang, Hong; Su, Baochang; Ye, Xunda; Luo, Man

    2016-04-01

    Spectrophotometry is a simple hemolytic evaluation method commonly used in new drugs,biomedical materials and blood products.It is for the quantitative analysis of the characteristic absorption peaks of hemoglobin.Therefore,it is essential to select the correct detection wavelength when the evaluation system has influences on the conformation of hemoglobin.Based on the study of changes in the characteristic peaks over time of the hemolysis supernatant in four systems,namely,cell culture medium,phosphate buffered saline(PBS),physiological saline and banked blood preservation solution,using continuous wavelength scanning,the selections of detection wavelength were proposed as follows.In the cell culture medium system,the wavelength of 415 nm should be selected within 4h;,near 408 nm should be selected within 4~72h.In PBS system,within 4h,541 nm,577nm or 415 nm should be selected;4~72h,541 nm,577nm or near 406 nm should be selected.In physiological saline system,within 4h,414 nm should be selected;4~72h,near 405 nm should be selected;within 12 h,541nm or 577 nm could also be selected.In banked blood preservation solution system,within 72 h,415nm,540 nm or 576 nm should be selected.

  12. Diagnosis of Smith-Lemli-Opitz syndrome by ultraviolet spectrophotometry

    Directory of Open Access Journals (Sweden)

    F.B. Scalco

    2003-10-01

    Full Text Available Smith-Lemli-Opitz syndrome (SLOS is an autosomal recessive disorder due to an inborn error of cholesterol metabolism, characterized by congenital malformations, dysmorphism of multiple organs, mental retardation and delayed neuropsychomotor development resulting from cholesterol biosynthesis deficiency. A defect in 3ß-hydroxysteroid-delta7-reductase (delta7-sterol-reductase, responsible for the conversion of 7-dehydrocholesterol (7-DHC to cholesterol, causes an increase in 7-DHC and frequently reduces plasma cholesterol levels. The clinical diagnosis of SLOS cannot always be conclusive because of the remarkable variability of clinical expression of the disorder. Thus, confirmation by the measurement of plasma 7-DHC levels is needed. In the present study, we used a simple, fast, and selective method based on ultraviolet spectrophotometry to measure 7-DHC in order to diagnose SLOS. 7-DHC was extracted serially from 200 µl plasma with ethanol and n-hexane and the absorbance at 234 and 282 nm was determined. The method was applied to negative control plasma samples from 23 normal individuals and from 6 cases of suspected SLOS. The method was adequate and reliable and 2 SLOS cases were diagnosed.

  13. Determination of molybdenum in flotation concentrates by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Ise, Kazuo

    1978-01-01

    Molybdenum was determined by atomic absorption spectrophotometry in 0.05 N ammoniacal solution after the decomposition of the concentrate with aqua regia. Negros ore from Philippines was used as a flotation feed, which contained chalcopyrites and calcium-magnesium minerals. Among the metals tested copper, iron and the alkaline earths interfered. Less than 50 ppm of copper yielded lower results for molybdenum. Higher results came out with more than 50 ppm of copper. In the presence of iron and citric acid (0.4 g/100 ml) which is a suppressor for hydroxide formation, a lower estimation resulted for molybdenum. Calcium interfered, lower results by 2 and >10% being obtained with respective 2.5 and 20 ppm of calcium. More than 20 ppm of magnesium behaved similarly. Sodium sulfate (0.5 g/100 ml) served as the suppressor for copper, iron and citric acid; 100 ppm each of copper and iron did not interfere in this way. Interferences due to calcium and magnesium (less than 60 ppm) was able to be masked by the addition of sodium silicate (200 ppm as silica). The analysis of flotation products and synthetic samples consisting of molybdenite, chalcopyrite, calcium chloride and magnesium sulfate revealed that the atomic absorption method can be applied to the analysis of the concentrates for molybdenum with an error of about 2%. (auth.)

  14. Spectrophotometry of the double QSO, 0957+561

    International Nuclear Information System (INIS)

    Wills, B.J.; Wills, D.

    1980-01-01

    We report new spectrophotometry of the double QSO, 0957+561, and show that the absorption line region in each light path is very similar in redshift (Δv +- 14 km s -1 rms), in column density of Fe + (approx.3 x 10 14 cm -2 ), and in velocity dispersion (approx.40 km s -1 ). The simplest interpretation of these results is a very massive object deflecting the light from a more distant QSO. Based on this hypothesis we find that the differences between the emission line and continuum spectra may be explained by differential reddening, implying a reddening-corrected flux ratio B/Aapprox. =2--4. This ratio is different from that found at radio wavelengths (0.7 at 6 cm), but can be explained, based on the gravitational lens hypothesis, by different flux variability at radio and optical wavelengths; however, we have found no evidence for optical variability. Another difficulty may be that a point-mass gravitational lens would need to have a mass-to-light ratio greater than 1000, if it is closer than z=0.4; at larger distances its mass would be very large (approx.10 14 M/sub sun/ at z=1.2). Observations obtained so far might be explained if two massive QSOs are actually closer together than appear to be, as a result of mutual gravitational deflection of the light. 1

  15. Direct DOC and nitrate determination in water using dual pathlength and second derivative UV spectrophotometry.

    Science.gov (United States)

    Causse, Jean; Thomas, Olivier; Jung, Aude-Valérie; Thomas, Marie-Florence

    2017-01-01

    UV spectrophotometry is largely used for water and wastewater quality monitoring. The measurement/estimation of specific and aggregate parameters such as nitrate and dissolved organic carbon (DOC) is possible with UV spectra exploitation, from 2 to multi wavelengths calibration. However, if nitrate determination from UV absorbance is known, major optical interferences linked to the presence of suspended solids, colloids or dissolved organic matter limit the relevance of UV measurement for DOC assessment. A new method based on UV spectrophotometric measurement of raw samples (without filtration) coupling a dual pathlength for spectra acquisition and the second derivative exploitation of the signal is proposed in this work. The determination of nitrate concentration is carried out from the second derivative of the absorbance at 226 nm corresponding at the inflexion point of nitrate signal decrease. A short optical pathlength can be used considering the strong absorption of nitrate ion around 210 nm. For DOC concentration determination the second derivative absorbance at 295 nm is proposed after nitrate correction. Organic matter absorbing slightly in the 270-330 nm window, a long optical pathlength must be selected in order to increase the sensitivity. The method was tested on several hundred of samples from small rivers of two agricultural watersheds located in Brittany, France, taken during dry and wet periods. The comparison between the proposed method and the standardised procedures for nitrate and DOC measurement gave a good adjustment for both parameters for ranges of 2-100 mg/L NO3 and 1-30 mg/L DOC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Serum paraquat concentration detected by spectrophotometry in patients with paraquat poisoning

    Science.gov (United States)

    Li, Chang-bin; Li, Xin-hua; Wang, Zhen; Jiang, Cheng-hua; Peng, Ai

    2011-01-01

    BACKGROUND: Paraquat (PQ) is a world-wide used herbicide and also a type of common poison for suicide and accidental poisoning. Numerous studies have proved that the concentration of serum PQ plays an important role in prognosis. Spectrophotometry, including common spectrophotometry and second-derivative spectrophotometry, is commonly used for PQ detection in primary hospitals. So far, lack of systematic research on the reliability of the method and the correlation between clinical features of patients with PQ poisoning and the test results has restricted the clinical use of spectrophotometry. This study aimed to evaluate the reliability and value of spectrophotometry in detecting the concentration of serum PQ. METHODS: The wavelengths for detecting the concentration of serum PQ by common and second-derivative spectrophotometry were determined. Second-derivative spectrophotometry was applied to detect the concentration of serum PQ. The linear range and precision for detection of PQ concentration by this method were confirmed. The concentration of serum PQ shown by second-derivative spectrophotometry and HPLC were compared in 8 patients with PQ poisoning. Altogether 21 patients with acute poisoning 4 hours after PQ ingestion treated in the period of October 2008 to September 2010 were retrospectively reviewed. The patients were divided into higher and lower than 1.8 μg/mL groups based on their concentrations of serum PQ measured by second-derivative spectrophotometry on admission. The severity of clinical manifestations between the two groups were analyzed with Student's t test or Fisher's exact test. RESULTS: The absorption peak of 257 nm could not be found when common spectrophotometry was used to detect the PQ concentration in serum. The calibration curve in the 0.4–8.0 μg/mL range for PQ concentration shown by second-derivative spectrophotometry obeyed Beer's law with r=0.996. The average recovery rates of PQ were within a range of 95.0% to 99.5%, relative

  17. Application of spectrophotometry for determination of analytes in high percentage levels

    International Nuclear Information System (INIS)

    Koteswara Rao, M.; Ram Mohan, Vijaya; Yadav, R.B.

    2009-01-01

    This paper describes the application of differential Spectrophotometry for the determination of analytes in high concentration levels unlike the conventional photometric methods that are useful for measuring concentration at trace levels. Differential spectrophotometry is based on measuring the absorbance of the test solution against a standard of accurately known concentration instead of a reagent blank or pure solvent. In this way, the error in measurement is confined to the difference in the two concentrations and is minimized. Thus the error is much smaller than in conventional Spectrophotometry, which therefore allows its application for determining analytes in major concentration. This method was applied for the assay of Niobium and Titanium used as strategic materials in various field. (author)

  18. Modulation of Cartilage Degradation Biomarkers Reflect the Activation and Inhibition of Pro-Inflammatory Cytokine Signaling in an Ex Vivo Model of Bovine Cartilage

    DEFF Research Database (Denmark)

    Kjelgaard-Petersen, Cecilie Freja; Sharma, Neha; Kayed, Ashref

    2017-01-01

    -inflammatory treatments for inflammatory arthritis. The aim of this study was to investigate the effect of small molecule inhibitors targeting 4 main pro-inflammatory signaling pathways (p38, Syk, IκBα, and STAT) on Oncostatin M (OSM) and Tumor Necrosis Factor α (TNFα) stimulated cartilage....

  19. Determination of micro amounts of samarium and europium by analogue derivative spectrophotometry

    International Nuclear Information System (INIS)

    Ishii, H.; Satoh, K.

    1982-01-01

    Derivative spectrophotometry using the analogue differentiation circuit was applied to the determination of samarium and europium at ppm levels. By measuring the second or the fourth derivative spectra of the characteristic absorption bands of both the rare earth ions around 400 nm, they can be determined directly and selectively in the presence of large amounts of most other rare earths without any prior separation. Further, aptly selecting conditions for the measurement of the derivative spectra, the simultaneous determination of both the rare earth elements was feasible. The principle and the characteristics of analogue derivative spectrophotometry are also described. (orig.) [de

  20. Estimation of nitrate and nitrogen forms of vegetables by UV-spectrophotometry after photo-oxydation.

    Science.gov (United States)

    Ribeiro, T; Depres, S; Couteau, G; Pauss, A

    2003-01-01

    An alternative method for the estimation of nitrate and nitrogen forms in vegetables is proposed. Nitrate can be directly estimated by UV-spectrophotometry after an extraction step with water. The other nitrogen compounds are photo-oxidized into nitrate, and then estimated by UV-spectrophotometry. An oxidative solution of sodium persulfate and a Hg-UV lamp is used. Preliminary assays were realized with vegetables like salade, spinachs, artichokes, small peas, broccolis, carrots, watercress; acceptable correlations between expected and experimental values of nitrate amounts were obtained, while the detection limit needs to be lowered. The optimization of the method is underway.

  1. The Reflective Learning Continuum: Reflecting on Reflection

    Science.gov (United States)

    Peltier, James W.; Hay, Amanda; Drago, William

    2005-01-01

    The importance of reflection to marketing educators is increasingly recognized. However, there is a lack of empirical research that considers reflection within the context of both the marketing and general business education literature. This article describes the use of an instrument that can be used to measure four identified levels of a…

  2. Magnetic resonance cell-tracking studies: spectrophotometry-based method for the quantification of cellular iron content after loading with superparamagnetic iron oxide nanoparticles.

    Science.gov (United States)

    Böhm, Ingrid

    2011-08-01

    The purpose of this article is to present a user-friendly tool for quantifying the iron content of superparamagnetic labeled cells before cell tracking by magnetic resonance imaging (MRI). Iron quantification was evaluated by using Prussian blue staining and spectrophotometry. White blood cells were labeled with superparamagnetic iron oxide (SPIO) nanoparticles. Labeling was confirmed by light microscopy. Subsequently, the cells were embedded in a phantom and scanned on a 3 T magnetic resonance tomography (MRT) whole-body system. Mean peak wavelengths λ(peak) was determined at A(720 nm) (range 719-722 nm). Linearity was proven for the measuring range 0.5 to 10 μg Fe/mL (r  =  .9958; p  =  2.2 × 10(-12)). The limit of detection was 0.01 μg Fe/mL (0.1785 mM), and the limit of quantification was 0.04 μg Fe/mL (0.714 mM). Accuracy was demonstrated by comparison with atomic absorption spectrometry. Precision and robustness were also proven. On T(2)-weighted images, signal intensity varied according to the iron concentration of SPIO-labeled cells. Absorption spectrophotometry is both a highly sensitive and user-friendly technique that is feasible for quantifying the iron content of magnetically labeled cells. The presented data suggest that spectrophotometry is a promising tool for promoting the implementation of magnetic resonance-based cell tracking in routine clinical applications (from bench to bedside).

  3. Magnetic Resonance Cell-Tracking Studies: Spectrophotometry-Based Method for the Quantification of Cellular Iron Content after Loading with Superparamagnetic Iron Oxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Ingrid Böhm

    2011-07-01

    Full Text Available The purpose of this article is to present a user-friendly tool for quantifying the iron content of superparamagnetic labeled cells before cell tracking by magnetic resonance imaging (MRI. Iron quantification was evaluated by using Prussian blue staining and spectrophotometry. White blood cells were labeled with superparamagnetic iron oxide (SPIO nanoparticles. Labeling was confirmed by light microscopy. Subsequently, the cells were embedded in a phantom and scanned on a 3 T magnetic resonance tomography (MRT whole-body system. Mean peak wavelengths Λpeak was determined at A720nm (range 719–722 nm. Linearity was proven for the measuring range 0.5 to 10 μg Fe/mL (r = .9958; p = 2.2 × 10−12. The limit of detection was 0.01 μg Fe/mL (0.1785 mM, and the limit of quantification was 0.04 μg Fe/mL (0.714 mM. Accuracy was demonstrated by comparison with atomic absorption spectrometry. Precision and robustness were also proven. On T2-weighted images, signal intensity varied according to the iron concentration of SPIO-labeled cells. Absorption spectrophotometry is both a highly sensitive and user-friendly technique that is feasible for quantifying the iron content of magnetically labeled cells. The presented data suggest that spectrophotometry is a promising tool for promoting the implementation of magnetic resonance-based cell tracking in routine clinical applications (from bench to bedside.

  4. Teaching Beer's Law and Absorption Spectrophotometry with a Smart Phone: A Substantially Simplified Protocol

    Science.gov (United States)

    Kuntzleman, Thomas S.; Jacobson, Erik C.

    2016-01-01

    A very simple protocol for teaching Beer's Law and absorption spectrophotometry using a smart phone is described. Materials commonly found in high school chemistry laboratories or even around the house may be used. Data collection and analysis is quick and easy. Despite the simple nature of the experiment, excellent results can be achieved.

  5. Kombineret laser Doppler flowmetri og spectrophotometri som metode til vurdering af mikrocirculation

    DEFF Research Database (Denmark)

    Berggren Olsen, Mette; Sørensen, Hanne Birke; Houlind, Kim Christian

    Kombineret laser Doppler flowmetri og spectrophotometri som metode til vurdering af mikrocirculation Berggren, MB, reservelæge, Karkirurgisk Afdeling, Kolding, mette.marie.berggren.olsen@slb.regionsyddanmark.dk; Houlind, K, lektor, afdelingslæge, Ph.d., Karkirurgisk afdeling, Kolding, kim...

  6. Practical application of solid phase spectrophotometry in analysis of materials and goods of mining and metallurgy

    International Nuclear Information System (INIS)

    Duan Qunzhang

    1999-01-01

    The author reviewed recent development and practical application of solid phase spectrophotometry in analysis of materials and goods of mining-metallurgy. Separation and preconcentration and conditions of coloring determination, sensitivity and range of detection, as well as interference of corresponding method are discussed

  7. Water contentwater of determination of cationic polystyrene sulfonate resins by infrared spectrophotometry

    International Nuclear Information System (INIS)

    Noki, V.

    1987-01-01

    A method of the determination of water content in polystyrene sulfonate ion-exchange resins in the presence of alkaline earth counter-ions by I.R. spectrophotometry is proposed. This method does not hold in the case of transition metal due to the formation of coordinated complexes with water molecules.

  8. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  9. An application of micelle solubilization spectrophotometry in the determination of thorium

    International Nuclear Information System (INIS)

    Peng Changhai; Zeng Xiaoming

    1988-01-01

    In this review article the characteristics of the analytical method of Th by means of micelle solubilization spectrophotometry are described and the mechanism of the solubilization and chemical reactions involved is discussed. Also the various color-developing reagents that have been used for this determination are described and compared

  10. Determination of astaxanthin in Haematococcus pluvialis by first-order derivative spectrophotometry.

    Science.gov (United States)

    Liu, Xiao Juan; Juan, Liu Xiao; Wu, Ying Hua; Hua, Wu Ying; Zhao, Li Chao; Chao, Zhao Li; Xiao, Su Yao; Yao, Xiao Su; Zhou, Ai Mei; Mei, Zhou Ai; Liu, Xin; Xin, Liu

    2011-01-01

    A highly selective, convenient, and precise method, first-order derivative spectrophotometry, was applied for the determination of astaxanthin in Haematococcus pluvialis. Ethyl acetate and ethanol (1:1, v/v) were found to be the best extraction solvent tested due to their high efficiency and low toxicity compared with nine other organic solvents. Astaxanthin coexisting with chlorophyll and beta-carotene was analyzed by first-order derivative spectrophotometry in order to optimize the conditions for the determination of astaxanthin. The results show that when detected at 432 nm, the interfering substances could be eliminated. The dynamic linear range was 2.0-8.0 microg/mL, with a correlation coefficient of 0.9916. The detection threshold was 0.41 microg/mL. The RSD for the determination of astaxanthin was in the range of 0.01-0.06%; the results of recovery test were 98.1-108.0%. The statistical analysis between first-order derivative spectrophotometry and HPLC by T-testing did not exceed their critical values, revealing no significant differences between these two methods. It was proved that first-order derivative spectrophotometry is a rapid and convenient method for the determination of astaxanthin in H. pluvialis that can eliminate the negative effect resulting from the coexistence of astaxanthin with chlorophyll and beta-carotene.

  11. Selenium determination in biological material by atomic absorption spectrophotometry in graphite furnace and using vapor generation

    International Nuclear Information System (INIS)

    Carvalho Vidal, M. de F. de.

    1984-01-01

    The applicability of the atomic absorption spectrophotometry to the determination of selenium in biological material using vapor generation and electrothermal atomization in the graphite furnace was investigated. Instrumental parameters and the analytical conditions of the methods were studied. Decomposition methods for the samples were tested, and the combustion in the Wickbold apparatus was chosen. (author) [pt

  12. Measurement of uranium concentration by molecular absorption spectrophotometry by means optical fibers

    International Nuclear Information System (INIS)

    Gauna, Alberto C.; Pascale, Ariel A.

    1996-01-01

    An on-line method for measuring the concentration of uranium in uranyl nitrate-nitric acid aqueous solutions is described. The method is based on molecular absorption spectrophotometry with transmission of light by means of optical fibers. It is ideally suited for control and processes development applications. (author)

  13. A laboratory manual for the determination of metals in water and wastewater by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Smith, R.

    1983-01-01

    This guide presents, in addition to a brief discussion of the basic principles and practical aspects of atomic absorption spectrophotometry, a scheme of analysis for the determination of 19 metals in water and wastewater, 16 by flame atomic absorption and 3 by vapour generation techniques. Simplicity, speed and accuracy were the main criteria considered in the selection of the various methods

  14. Optical fiber couplers for spectrophotometry. Perspectives for in-situ on-line and remote measurements

    International Nuclear Information System (INIS)

    Boisde, G.; Linger, C.; Chevalier, G.; Perez, J.J.

    1983-01-01

    Optical fiber couplers have been developed specially for nuclear chemical spectrophotometric applications. Coupling devices are described for TELEPHOT industrial photometers and some commercial spectrophotometer, together with the probes and measurement cells employed. The value of optical multiplexing is mentioned. Non nuclear applications in medical analysis are also mentioned, together with the possibilities offered by these devices for uses other than spectrophotometry [fr

  15. Reflective photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Lentine, Anthony L.; Nielson, Gregory N.; Cruz-Campa, Jose Luis; Okandan, Murat; Goeke, Ronald S.

    2018-03-06

    A photovoltaic module includes colorized reflective photovoltaic cells that act as pixels. The colorized reflective photovoltaic cells are arranged so that reflections from the photovoltaic cells or pixels visually combine into an image on the photovoltaic module. The colorized photovoltaic cell or pixel is composed of a set of 100 to 256 base color sub-pixel reflective segments or sub-pixels. The color of each pixel is determined by the combination of base color sub-pixels forming the pixel. As a result, each pixel can have a wide variety of colors using a set of base colors, which are created, from sub-pixel reflective segments having standard film thicknesses.

  16. Spectrophotometry or visual inspection to most reliably detect xanthochromia in subarachnoid hemorrhage: systematic review.

    Science.gov (United States)

    Chu, Kevin; Hann, Angus; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2014-09-01

    We assess the sensitivity and specificity of xanthochromia as adjudicated by visual inspection and spectrophotometry at predicting the presence of cerebral aneurysm in patients with suspected subarachnoid hemorrhage who have a normal computed tomography (CT) head scan result. A systematic review was performed. MEDLINE and EMBASE databases were searched. Relevant studies with clinical data on the diagnostic accuracy of visual inspection or spectrophotometry were considered. Patients who had a normal CT head scan result followed by a lumbar puncture were included in this review. Sensitivities, specificities, and heterogeneity (I(2)) were calculated. Subgroup analyses were performed to explore reasons for the heterogeneity. There were major methodological limitations in the studies found. Twenty-two relevant articles were heterogeneous in regard to time to lumbar puncture, spectrophotometry methods, and follow-up of patients not undergoing cerebral angiography. Twelve of the 22 studies selected patients on the basis of a cerebral aneurysm or subarachnoid hemorrhage on imaging, or a positive lumbar puncture result. These studies were excluded from our initial analysis, which included only patients with clinically suspected subarachnoid hemorrhage. In this initial analysis, pooled estimates of sensitivity and specificity for spectrophotometry were 87% (95% confidence interval [CI] 71% to 96%; I(2)=26%) and 86% (95% CI 84% to 88%; I(2)=96%), respectively. For visual inspection, pooled sensitivity and specificity were 83% (95% CI 59% to 96%; I(2)=52%) and 96% (95% CI 93% to 97%; I(2)=76%), respectively. Sensitivity estimates are difficult to interpret without knowing time to lumbar puncture. The heterogeneity in the underlying studies, combined with significant overlap in pooled confidence limits, makes it impossible to provide a definite conclusion about the diagnostic accuracy of spectrophotometry versus visual inspection. Copyright © 2014 American College of Emergency

  17. Redox effects in ordinary chondrites and implications for asteroid spectrophotometry

    Science.gov (United States)

    Mcsween, Harry Y., Jr.

    1992-01-01

    The sensitivity of reflectance spectra to mean ferrous iron content and olivine and pyroxene proportion enhancements in the course of metamorphic oxidation is presently used to examine whether metamorphically-induced ranges in mineralogy, and corresponding spectral parameters, may explain the observed variations in S-asteroid rotational spectra. The predicted spectral variations within any one chondrite class are, however, insufficient to account for S-asteroid rotational spectra, and predicted spectral-range slopes have a sign opposite to the rotational measurements. Metamorphic oxidation is found unable to account for S-asteroid rotational spectra.

  18. Symbiotic binaries. Part 1. Spectrophotometry of AX Persei

    International Nuclear Information System (INIS)

    Mikolajewska, J.; Iijima, T.

    1987-01-01

    Secular and eclipse variations of optical emission lines during almost three orbital cycles of the symbiotic star AX Per are presented. The permitted lines show pronounced but nontotal eclipse effects while forbidden lines (i.e. [O3], [Ne3], [Fe7]) do not show such effects. The data are discussed in terms of physical conditions and geometry of the line formation region. The possible presence of the reflection of a hot star light from a red-giant companion is considered. 37 refs., 2 figs., 1 tab. (author)

  19. Nutrient dynamics and oceanographic features in the central Namibian upwelling region as reflected in δ15N-signals of suspended matter and surface sediments

    Directory of Open Access Journals (Sweden)

    S. Meisel

    2011-08-01

    Full Text Available The study deals with the modern situation of the northern Benguela Upwelling, directing particular attention to the shelf region off central Namibia (21 to 24° S. At the centre of the investigation is the comparison of δ15N-records in surface sediments (δ15Nsediment with suspended particulate matter (δ15NSPM from the surface ocean. In addition to that, water column profiles (including hydrographic data provide an insight into changes of δ15NSPM with depth and elucidate potential offsets between δ15NSPM and δ15Nsediment. The parallel spatial trend of δ15Nsediment and surface ocean δ15NSPM shows that secondary processes are not so pronounced as to obliterate the signal generated in the surface waters. Highest δ15N-signatures are found right off the coast where water temperatures are lowest. Concomitantly high productivity rates and low bottom oxygen suggest the upwelling of denitrified source waters. With increasing distance offshore, δ15N declines unexpectedly, reaching a minimum above the shelf break. Beyond that, the trend reverses to "normal" with δ15N-signals continuously increasing towards the mesopelagic ocean. The decrease in δ15Nsediment and surface ocean δ15NSPM with increasing distance to the coast disagrees with the concept of Rayleigh fractionation kinetics, viz. the progressive 15N-enrichment of the nitrate pool as it is gradually used up by phytoplankton growth. On the basis of the available evidence, the downward trend of δ15N results from decreased relative nitrate consumption, resting on a combination of reduced primary production and the existence of an ulterior source of nutrients. Nutrient replenishment seems to occur via an additional upwelling front at the edge of the shelf as well as tapping of subsurface nitrate through sufficiently deep penetration of wind- and wave-induced mixing over large areas of the shelf. Both mechanisms are considered capable of working against the expected nutrient drawdown (i.e. 15

  20. Personal Reflections

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education. Personal Reflections. Articles in Resonance – Journal of Science Education. Volume 6 Issue 3 March 2001 pp 90-93 Personal Reflections. Why did I opt for Career in Science? Jayant V Narlikar · More Details Fulltext PDF. Volume 9 Issue 8 August 2004 pp 89-89 ...

  1. Reflection groups

    International Nuclear Information System (INIS)

    Eggermont, G.

    2006-01-01

    In 2005, PISA organised proactive meetings of reflection groups on involvement in decision making, expert culture and ethical aspects of radiation protection.All reflection group meetings address particular targeted audiences while the output publication in book form is put forward

  2. Reflection ciphers

    DEFF Research Database (Denmark)

    Boura, Christina; Canteaut, Anne; Knudsen, Lars Ramkilde

    2017-01-01

    study the necessary properties for this coupling permutation. Special care has to be taken of some related-key distinguishers since, in the context of reflection ciphers, they may provide attacks in the single-key setting.We then derive some criteria for constructing secure reflection ciphers...

  3. Quantifying Reflection

    DEFF Research Database (Denmark)

    Alcock, Gordon Lindsay

    2013-01-01

    ´ These are all based on Blooms taxonomy and levels of competence and form a major part of individual student and group learning portfolios. Key Words :Project-Based learning, Reflective Portfolios, Self assessment, Defining learning gains, Developing learning strategies , Reflections on and for learning....... It contrasts the students’ self-assessment in a range of ‘product’ skills such as Revit, Structural Design, Mathematics of construction, Technical Installations; as well as ‘process’ competencies such as ‘Working in a team’, Sharing knowledge, Maintaining a portfolio and Reflecting ON learning and FOR learning......This paper documents 1st semester student reflections on “learning to learn” in a team-based PBL environment with quantitative and qualitative student reflective feedback on the learning gains of 60 Architectural Technology and Construction Management students at VIA University College, Denmark...

  4. The Uranian satellites and Hyperion - New spectrophotometry and compositional implications

    Science.gov (United States)

    Brown, R. H.

    1983-12-01

    New reflectance spectra at 3.5 percent resolution have been obtained for Ariel, Titania, Oberon, and Hyperion in the 0.8 to 1.6-micron spectrum region. The new spectra show no absorptions other than the 1.5 micron water-ice feature (within the precision of the data), and demonstrate extension into the 0.8- to 1.6 micron region of the 1.5- to 2.5 micron spectral similarity ofo Ariel to Hyperion (Brown and Cruikshank, 1983). The new data confirm the presence of a dark, spectrally bland component on/in the water-ice surfaces of the Uranian satellites, which, with some reservations, has spectral similarities to the dark substance on the leading side of lapetus and the dark material on/in the surface of Hyperion, as well as other dark, spectrally neutral substances such as charcoal. Attempts were made to match the spectra of Ariel, Titania, and Oberon with additive reflectance mixes (aeral coverage) of fine-grained water frost and various dark components such as charcoal, lampblack, and charcoal-water-ice mixtures. The results were broad limits on the amounts of possible areal coverage of a charcoal-like spectral component on the surfaces of the Uranian satellites, but the data are not of sufficient precision to conclusively determine whether the dominant mode of contaminant dispersal is areal or voluminal. The effect of highly variegated albedos on the diameters derived by Brown, Cruikshank, and Morrison (1982) is found to be small.

  5. Using UV-VIS spectrophotometry for determining ecotoxicity of selected non-steroidal anti-inflammatory drugs

    Czech Academy of Sciences Publication Activity Database

    Čapka, Lukáš; Zlámalová Gargošová, H.; Vávrová, M.

    2015-01-01

    Roč. 24, 12C (2015), s. 4758-4762 ISSN 1018-4619 Institutional support: RVO:68081715 Keywords : ecotoxicity * NSAIDs * UV-VIS spectrophotometry Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.372, year: 2015

  6. Indirect determination of uranium by atomic-absorption spectrophotometry using an air-acetylene flame

    International Nuclear Information System (INIS)

    Alder, J.F.; Das, B.C.

    1977-01-01

    An indirect method has been developed for the determination of uranium by atomic-absorption spectrophotometry using an air-acetylene flame. Use is made of the reduction of copper(II) by uranium(IV) followed by complex formation of the copper(I) ions so produced with neocuproine (2,9-dimethyl-1,10-phenanthroline) and finally the determination of copper in this complex by atomic-absorption spectrophotometry. The results show that the method can be recommended, provided that care is taken to ensure the complete reduction of uranium(VI) to uranium(IV). The sensitivity of the method is 4.9 μg of uranium and the upper limit 500 μg without dilution. (author)

  7. Neutron dosimetry by UV and IR spectrophotometry of the newly developed dyed ECE tracks

    International Nuclear Information System (INIS)

    Sohrabi, M.; Sadeghi Bajd, S.

    1990-01-01

    New, large and high-contrasted dyed ECE recoil tracks have been successfully developed. The chief reason for this development has been the provision of large photon-absorbing sites on a non-absorbing unaffected polymer surface for UV and IR spectrophotometry. In this approach, ECE recoil tracks in polycarbonate were dyed using our optimised conditions; sensitisation in 20% by weight acrylic acid at 75 0 C for 3.5 h and dyeing in 3% by weight eosin at 95 0 C for 4 h. Spectrophotometry by UV and IR, track counting and optical densitometry were applied to the samples. These preliminary studies showed some promise for UV absorbance measurements for routine large-scale applications. the results of which are presented and discussed. (author)

  8. Determination of macro nickel, vanadium and iron in crude oil and residues by derivative spectrophotometry

    International Nuclear Information System (INIS)

    Liu, W.; Wang, L.; Li, X.

    1992-01-01

    In this paper, a new method with derivative spectrophotometry and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol as the chromogenic reagent in buffer solution of different pH developed for determining micro amounts of nickel. Vanadium and iron in crude oil and residues is reported. Forth-, Second- and Third-, Fourth-order derivative spectrophotometry were applied to determine nickel, nickel and vanadium, nickel and iron in crude oil and residues, respectively. The derivative maximums chosen for the measurement were at 556 nm for nickel, 540 nm and 643 nm for nickel and vanadium, 524 nm and 604 nm for nickel and iron. Beer's law is valid for the range 1.0 x 10 -6 to 2.5 x 10 -5 M

  9. Combined spectrophotometry and tensile measurements of human connective tissues: potentials and limitations.

    Science.gov (United States)

    Ernstberger, Markus; Sichting, Freddy; Baselt, Tobias; Hartmann, Peter; Aust, Gabriela; Hammer, Niels

    2013-06-01

    Strain-dependent transmission data of nine iliotibial tract specimens are determined using a custom-built optical setup with a halogen light source and an industrial norm material testing machine. Polarized light microscopy and hematoxylin-eosin staining indicated that lateral contraction of collagen structures is responsible for total intensity variations during a 20-cycle preconditioning and a 5-cycle tensile test. Tensile force progress is opposite to total transmission progress. Due to dehydration, wavelength-specific radiation intensity shifting is determined during the test, primarily noticeable in a water absorption band between 1400 and 1500 nm. The results show the capability of integrating spectrophotometry technology into biomechanics for determining structural alterations of human collagen due to applied strain. Being more sensitive to drying, spectrophotometry may likely serve as a quality control in stress-strain testing of biological structures.

  10. [Noninvasive total hemoglobin monitoring based on multiwave spectrophotometry in obstetrics and gynecology].

    Science.gov (United States)

    Pyregov, A V; Ovechkin, A Iu; Petrov, S V

    2012-01-01

    Results of prospective randomized comparative research of 2 total hemoglobin estimation methods are presented. There were laboratory tests and continuous noninvasive technique with multiwave spectrophotometry on the Masimo Rainbow SET. Research was carried out in two stages. At the 1st stage (gynecology)--67 patients were included and in second stage (obstetrics)--44 patients during and after Cesarean section. The standard deviation of noninvasive total hemoglobin estimation from absolute values (invasive) was 7.2 and 4.1%, an standard deviation in a sample--5.2 and 2.7 % in gynecologic operations and surgical delivery respectively, that confirms lack of reliable indicators differences. The method of continuous noninvasive total hemoglobin estimation with multiwave spectrophotometry on the Masimo Rainbow SET technology can be recommended for use in obstetrics and gynecology.

  11. Determination of rare earth element content in yttrium aluminium garnet crystals by absorption spectrophotometry method

    International Nuclear Information System (INIS)

    Mejl'man, M.L.; Kolomijtsev, A.I.; Baskakova, Z.M.; Bagdasarov, Kh.S.; Kevorkov, A.M.

    1985-01-01

    Possibility of determination of relative and absolute contents of impurity trivalent REE ions in yttrium aluminium garnet of (YAG) monocrystals has been studied by the absorption spectrophotometry method. Absorption spectra in UV and visible regions YAG monocrystals doped by REE are studied. For each admixture the characteristic lines or absorption bands not overlapping with lines of other admixtures are defined and investigated. The extinction coefficients of characteristic lines are determined which allow one to measure absolute REE admixture concentrations in garnet crystals. A conclusion is drawn that the absorption spectrophotometry method permits to measure REE admixture content in YAG monocrystals within the concentration range of approximately 1x10sup(-3)-5 mas. % with an accuracy not less than 20% (with sample thickness of approximately 1 cm)

  12. Determination of tantalum in standard steels by INAA and absorption spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Obrusnik, I; Posta, S [Ustav Jaderneho Vyzkumu, Rez (Czechoslovakia)

    1978-02-14

    Two analytical methods, instrumental neutron activation analysis (INAA) and absorption spectrophotometry with malachite green, have been used for the determination of tantalum in standard steels produced by the Research Institute of CKD Prague - steels No. 167 and No. 169 with expected concentrations of Ta 0.01% and 0.03%, respectively. INAA method consisted of irradiation of steel samples (chips) in a nuclear reactor and Ge(Li) ..gamma..-ray spectrometry after a cooling period of one month. A spectrophotometric determination is based on the extraction of ionic associate of TaF/sub 6//sup -/ with malachite green into Oenzene from a solution of diluted sulphuric acid and hydrofluoric acid. The results obtained by the two methods are in a good agreement. However, INAA method is more sensitive and precise then spectrophotometry for the determination of tantalum in steels in the above-mentioned concentration ranges.

  13. Determination of tantalum in standard steels by INAA and absorption spectrophotometry

    International Nuclear Information System (INIS)

    Obrusnik, I.; Posta, S.

    1978-01-01

    Two analytical methods, instrumental neutron activation analysis (INAA) and absorption spectrophotometry with malachite green, have been used for the determination of tantalum in standard steels produced by the Research Institute of CKD Prague - steels No. 167 and No. 169 with expected concentrations of Ta 0.01% and 0.03%, respectively. INAA method consisted of irradiation of steel samples (chips) in a nuclear reactor and Ge(Li) γ-ray spectrometry after a cooling period of one month. A spectrophotometric determination is based on the extraction of ionic associate of TaF 6 - with malachite green into Oenzene from a solution of diluted sulphuric acid and hydrofluoric acid. The results obtained by the two methods are in a good agreement. However, INAA method is more sensitive and precise then spectrophotometry for the determination of tantalum in steels in the above-mentioned concentration ranges. (author)

  14. Rapid and Sensitive Determination of Lipid Oxidation Using the Reagent Kit Based on Spectrophotometry (FOODLABfat System

    Directory of Open Access Journals (Sweden)

    Chang Woo Kwon

    2016-01-01

    Full Text Available The reliability and availability of FOODLABfat system for determining acid value (AV and peroxide value (POV were assessed during the hydrolytic rancidification and lipid oxidation of edible oils. This reagent kit based on spectrophotometry was compared to the official methods (ISO 660 and 3960 protocols based on manual titration employing the standard mixture for the simulated oxidation models and edible oils during the thermally induced oxidation at 180°C. The linear regression line of standard mixture and the significant difference of thermally oxidized time course study determined between them showed high correlations (R2=0.998 and p<0.05 in both AVs and POVs. Considering ISO protocols with a probability of human error in manual titration, the rapidness and simplicity of the reagent kit based on spectrophotometry make it a promising alternative to monitor the lipid oxidation of edible oils and lipid-containing foods.

  15. A new hydride generator for the determination of volatile elements by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Kersabiec, A.M. de

    1979-01-01

    The production of hydrides in order to use them for analysis by atomic absorption spectrophotometry depends on many parameters. A new apparatus has been designed for this specific operation. It is characterized by a reaction chamber with variable size and by appliances for regulation and control of the physical conditions of operation. Properties are both methodological studies and utilization in large scale analysis. The entire description of the apparatus is completed by an analytical study [fr

  16. The Use of Self-scanned Silicon Photodiode Arrays for Astronomical Spectrophotometry

    Science.gov (United States)

    Cochran, A. L.

    1984-01-01

    The use of a Reticon self scanned silicon photodiode array for precision spectrophotometry is discussed. It is shown that internal errors are + or - 0.003 mag. Observations obtained with a photodiode array are compared with observations obtained with other types of detectors with agreement, from 3500 A to 10500 A, of 1%. The photometric properties of self scanned photodiode arrays are discussed. Potential pitfalls are given.

  17. Improvement of precision method of spectrophotometry with inner standardization and its use in plutonium solutions analysis

    International Nuclear Information System (INIS)

    Stepanov, A.V.; Stepanov, D.A.; Nikitina, S.A.; Gogoleva, T.D.; Grigor'eva, M.G.; Bulyanitsa, L.S.; Panteleev, Yu.A.; Pevtsova, E.V.; Domkin, V.D.; Pen'kin, M.V.

    2006-01-01

    Precision method of spectrophotometry with inner standardization is used for analysis of pure Pu solutions. Improvement of the spectrophotometer and spectrophotometric method of analysis is done to decrease accidental constituent of relative error of the method. Influence of U, Np impurities and corrosion products on systematic constituent of error of the method, and effect of fluoride-ion on completeness of Pu oxidation in sample preparation are studied [ru

  18. Spectrophotometry of the nucleus of the Sy 2 galaxy Markarian 308

    International Nuclear Information System (INIS)

    Popov, V.N.; Khachikyan, Eh.E.

    1980-01-01

    The results of spectrophotometry of the Sy2 galaxy Markarian 308 are presented. The profiles of the emission lines [N II] lambda lambda 6583, 6548 A, Hsub(α), [O III] lambda lambda 5007, 4959 A and Hsub(β) are drawn. The electron density, electron temperature, mass and effective volume of the emitting gas are estimated. Markarian 308 shows now less activity compared with other Sy2 galaxies

  19. The analysis of coal-and coke ashes by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Coutinho, C.A.; Prates, H.T.; Pereira, C.P.

    1977-01-01

    In order to provide better conditions for the control of the chemical composition of the load in the USIMINAS blast furnaces, a method of analysis for sodium, potassium, iron, aluminium, calcium, magnesium and maganese in coal-and coke ash by atomic absorption spectrophotometry was developed. The precision of the calibration curves and the reproducibility of the results are given, together with an estimate of the speed compared with conventional methods of chemical analysis [pt

  20. Optical properties of orthodontic aligners?spectrophotometry analysis of three types before and after aging

    OpenAIRE

    Lombardo, Luca; Arreghini, Angela; Maccarrone, Roberta; Bianchi, Anna; Scalia, Santo; Siciliani, Giuseppe

    2015-01-01

    Background The aim was to assess and compare absorbance and transmittance values of three types of clear orthodontic aligners before and after two cycles of in vitro aging. Methods Nine samples of orthodontic aligners from three different manufacturers (Invisalign, Align Technology, Santa Clara, CA, USA; All-In, Micerium, Avegno, GE, Italy; F22 Aligner, Sweden & Martina, Due Carrare, PD, Italy) were selected, and each sample was subjected to spectrophotometry analysis of both its transmittanc...

  1. Analysis of nifedipine content in transdermal drug delivery system using non-destructive visible spectrophotometry technique

    International Nuclear Information System (INIS)

    Normaizira Hamidi; Normaizira Hamidi; Normaizira Hamidi; Mohd Nasir Taib; Mohd Nasir Taib; Wui, Wong Tin; Wui, Wong Tin

    2008-01-01

    The applicability of visible spectrophotometry technique as a tool to determine the drug content of polymeric film for use as a transdermal drug delivery system was investigated. Hydroxypropylmethycellulose (HPMC) was selected as the matrix polymer and nifedipine as the model drug. Blank and nifedipine-loaded HPMC films were prepared using the solvent evaporation method. The absorbance spectra of these films under the visible wavelengths between 400 and 800 nm were assessed and compared against the drug content values obtained by means of the conventional destructive UV- spectrophotometry technique. The latter required the use of a solvent system which contained methanol, a harmful organic component in pharmaceutical applications. The results indicated that the absorbance values, attributed to nifedipine, at the wavelengths of 545, 585, 638 and 755nm were significantly correlated to the drug content values obtained using the chemical assay method (Pearson correlation value: r = 0.990 and p < 0.01). The visible spectrophotometry technique is potentially suitable for use to determine the nifedipine content of films owing to its nature of characterization of transdermal drug delivery system which does not require sample destruction during the process of measurement. The samples are recoverable from test and analysis of the entire batch of samples is possible without the need of solvents and chemical reagents. (author)

  2. Studies of selected transuranium and lanthanide tri-iodides under pressure using absorption spectrophotometry

    International Nuclear Information System (INIS)

    Haire, R.G.; Young, J.P.; Peterson, J.R.; Tennessee Univ., Knoxville; Benedict, U.

    1987-01-01

    The anhydrous tri-iodides of plutonium, americium and curium under pressure have been investigated using absorption spectrophotometry. These initial studies on plutonium and curium tri-iodides together with the published data for americium tri-iodide show that the rhombohedral form of these compounds (BiI 3 -type structure) can be converted to the orthorhombic form (PuBr 3 -type structure) by applying pressure at room temperature. Absorption spectrophotometry can often differentiate between two crystallographic forms of a material and has been used in the present high-pressure studies to monitor the effects of pressure on the tri-iodides. A complication in these studies of the tri-iodides is a significant shift of their absorption edges with pressure from the near UV to the visible spectral region. With curium tri-iodide this shift causes interference with the major f-f absorption peaks and precludes identification by absorption spectrophotometry of the high pressure phase of CmI 3 . (orig.)

  3. Comparison of gas chromotography, spectrophotometry and near infrared spectroscopy to quantify prussic acid potential in forages.

    Science.gov (United States)

    Goff, Ben M; Moore, Kenneth J; Fales, Steven L; Pedersen, Jeffery F

    2011-06-01

    Sorghum [Sorghum bicolor (L.) Moench] has been shown to contain the cyanogenic glycoside dhurrin, which is responsible for the disorder known as prussic acid poisoning in livestock. The current standard method for estimating hydrogen cyanide (HCN) uses spectrophotometry to measure the aglycone, p-hydroxybenzaldehyde (p-HB), after hydrolysis. Errors may occur due to the inability of this method to solely estimate the absorbance of p-HB at a given wavelength. The objective of this study was to compare the use of gas chromatography (GC) and near infrared spectroscopy (NIRS) methods, along with a spectrophotometry method to estimate the potential for prussic acid (HCNp) of sorghum and sudangrasses over three stages maturities. It was shown that the GC produced higher HCNp estimates than the spectrophotometer for the grain sorghums, but lower concentrations for the sudangrass. Based on what is known about the analytical process of each method, the GC data is likely closer to the true HCNp concentrations of the forages. Both the GC and spectrophotometry methods yielded robust equations with the NIRS method; however, using GC as the calibration method resulted in more accurate and repeatable estimates. The HCNp values obtained from using the GC quantification method are believed to be closer to the actual values of the forage, and that use of this method will provide a more accurate and easily automated means of quantifying prussic acid. Copyright © 2011 Society of Chemical Industry.

  4. Reflectance Modeling

    Science.gov (United States)

    Smith, J. A.; Cooper, K.; Randolph, M.

    1984-01-01

    A classical description of the one dimensional radiative transfer treatment of vegetation canopies was completed and the results were tested against measured prairie (blue grama) and agricultural canopies (soybean). Phase functions are calculated in terms of directly measurable biophysical characteristics of the canopy medium. While the phase functions tend to exhibit backscattering anisotropy, their exact behavior is somewhat more complex and wavelength dependent. A Monte Carlo model was developed that treats soil surfaces with large periodic variations in three dimensions. A photon-ray tracing technology is used. Currently, the rough soil surface is described by analytic functions and appropriate geometric calculations performed. A bidirectional reflectance distribution function is calculated and, hence, available for other atmospheric or canopy reflectance models as a lower boundary condition. This technique is used together with an adding model to calculate several cases where Lambertian leaves possessing anisotropic leaf angle distributions yield non-Lambertian reflectance; similar behavior is exhibited for simulated soil surfaces.

  5. Reflective optics

    CERN Document Server

    Korsch, Dietrich

    1991-01-01

    This is the first book dedicated exclusively to all-reflective imaging systems. It is a teaching tool as well as a practical design tool for anyone who specializes in optics, particularly for those interested in telescopes, infrared, and grazing-incidence systems. The first part of the book describes a unified geometric optical theory of all-reflective imaging systems (from near-normal to grazing incidence) developed from basic principles. The second part discusses correction methods and a multitude of closed-form solutions of well-corrected systems, supplemented with many conventional and unc

  6. Comparative study of analytical methods by direct and first-derivative UV spectrophotometry for evaluation of losartan potassium in capsules

    Directory of Open Access Journals (Sweden)

    Rudy Bonfilio

    2010-03-01

    Full Text Available Losartan potassium is an antihypertensive non-peptide agent, which exerts its action by specific blockade of angiotensin II receptors. The aim of the present study was the validation and application of analytical methods for the quality control of losartan potassium 50 mg in pharmaceutical capsules, using direct and first-derivative UV spectrophotometry. Based on losartan potassium spectrophotometric characteristics, a signal at 205 nm of the zero-order spectrum and a signal at 234 nm of the first-derivative spectrum, were found adequate for quantification. The results were used to compare these instrumental techniques. The linearity between the signals and concentrations of losartan potassium in the ranges of 3.0-7.0 mg L-1 and 6.0-14.0 mg L-1 for direct and first-derivative spectrophotometry in aqueous solutions, respectively, presented a correlation coefficient (r of 0.9999 in both cases. The methods were applied for losartan potassium in capsule dosage obtained from local pharmacies, and were shown to be efficient, easy to apply and low cost. These methods do not use polluting reagents and require relatively inexpensive equipment.O losartano potássico é um agente anti-hipertensivo não peptídico, que exerce sua ação por bloqueio específico dos receptores da angiotensina II. Este trabalho propôs a validação e aplicação de métodos analíticos orientados ao controle de qualidade de losartano potássico 50 mg na forma farmacêutica cápsula, utilizando a espectrofotometria direta e derivada de primeira ordem na região do UV. Baseado nas características espectrofotométricas de losartano potássico, um sinal a 205 nm do espectro de ordem zero e um sinal a 234 nm do espectro de primeira derivada foram adequados para a quantificação. Os resultados foram usados para comparar essas duas técnicas instrumentais. O coeficiente de correlação entre as respostas e as concentrações de losartano potássico na faixa de 3,0-7,0 mg L-1 e 6

  7. Polarizer reflectivity variations

    International Nuclear Information System (INIS)

    Ozarski, R.G.; Prior, J.

    1980-01-01

    On Shiva the beam energy along the chain is monitored using available reflections and/or transmission through beam steering, splitting, and polarizing optics without the intrusion of any additional glass for diagnostics. On the preamp table the diagnostic signal is obtained from the signal transmitted through turning mirrors. At the input of each chain the signal is obtained from the transmission through one of the mirrors used for the chain input alignment sensor (CHIP). At the chain output the transmission through the final turning mirror is used. These diagnostics have proved stable and reliable. However, one of the prime diagnostic locations is at the output of the beta rod. The energy at this location is measured by collecting small reflections from the last polarizer surface of the beta Pockels cell polarizer package. Unfortunately, calibration of this diagnostic has varied randomly, seldom remaining stable for a week or more. The cause of this fluctuation has been investigated for the past year and'it has been discovered that polarizer reflectivity varies with humidity. This report will deal with the possible causes that were investigated, the evidence that humidity is causing the variation, and the associated mechanism

  8. Reflective Efficacy

    Directory of Open Access Journals (Sweden)

    Carla Bagnoli

    2018-04-01

    Full Text Available The purpose of this paper is to highlight some difficulties of Neil Sinhababu’s Humean theory of agency, which depend on his radically reductivist approach, rather than to his Humean sympathies. The argument is that Sinhababu’s theory builds upon a critique of reflective agency which is based on equivocation and misunderstandings of the Kantian approach. Ultimately, the objection is that his reductivist view is unequipped to address the rclassical problems of rational deliberation and agential authority.

  9. The quantification of spermatozoa by real-time quantitative PCR, spectrophotometry, and spermatophore cap size.

    Science.gov (United States)

    Doyle, Jacqueline M; McCormick, Cory R; DeWoody, J Andrew

    2011-01-01

    Many animals, such as crustaceans, insects, and salamanders, package their sperm into spermatophores, and the number of spermatozoa contained in a spermatophore is relevant to studies of sexual selection and sperm competition. We used two molecular methods, real-time quantitative polymerase chain reaction (RT-qPCR) and spectrophotometry, to estimate sperm numbers from spermatophores. First, we designed gene-specific primers that produced a single amplicon in four species of ambystomatid salamanders. A standard curve generated from cloned amplicons revealed a strong positive relationship between template DNA quantity and cycle threshold, suggesting that RT-qPCR could be used to quantify sperm in a given sample. We then extracted DNA from multiple Ambystoma maculatum spermatophores, performed RT-qPCR on each sample, and estimated template copy numbers (i.e. sperm number) using the standard curve. Second, we used spectrophotometry to determine the number of sperm per spermatophore by measuring DNA concentration relative to the genome size. We documented a significant positive relationship between the estimates of sperm number based on RT-qPCR and those based on spectrophotometry. When these molecular estimates were compared to spermatophore cap size, which in principle could predict the number of sperm contained in the spermatophore, we also found a significant positive relationship between sperm number and spermatophore cap size. This linear model allows estimates of sperm number strictly from cap size, an approach which could greatly simplify the estimation of sperm number in future studies. These methods may help explain variation in fertilization success where sperm competition is mediated by sperm quantity. © 2010 Blackwell Publishing Ltd.

  10. Infrared reflection nebulae in Orion Molecular Cloud

    International Nuclear Information System (INIS)

    Pendleton, Y.; Werner, M.W.; Capps, R.; Lester, D.; Hawaii Univ., Honolulu; Texas Univ., Austin)

    1986-01-01

    New observations of Orion Molecular Cloud 2 have been made from 1 to 100 microns using the NASA Infrared Telescope Facility and the Kuiper Airborne Observatory. An extensive program of polarimetry, photometry, and spectrophotometry has shown that the extended emission regions associated with two of the previously known near-infrared sources, IRS 1 and IRS 4, are infrared reflection nebulae, and that the compact sources IRS 1 and IRS 4 are the main luminosity sources in the cloud. The constraints from the far-infrared observations and an analysis of the scattered light from the IRS 1 nebula show that OMC-2/IRS 1 can be characterized by L of 500 solar luminosities or less and T of roughly 1000 K. The near-infrared albedo of the grains in the IRS 1 nebula is greater than 0.08. 27 references

  11. 8- to 13-micron spectrophotometry of Comet IRAS-Araki-Alcock

    Science.gov (United States)

    Feierberg, M. A.; Witteborn, F. C.; Johnson, J. R.; Campins, H.

    1984-01-01

    Spectrophotometry between 8.0 and 13.0 microns at 2 percent spectral resolution is presented for areas in and near the nuclear condensation of Comet IRAS-Araki-Alcock (1983d) on May 11 and 12, 1983. All the spectra can be fit very well by blackbody curves, and no 10-micron silicate emissions are seen. The temperature structure of the coma suggests the presence of small (radii less than 5 microns) dust particles within 150 km of the nucleus and larger ones further out. The change in the spatial distribution of the infrared flux between the two nights suggests that an outburst may have occurred sometime on May 11.

  12. CVF spectrophotometry of Pluto - Correlation of composition with albedo. [circularly variable filter

    Science.gov (United States)

    Marcialis, Robert L.; Lebofsky, Larry A.

    1991-01-01

    The present time-resolved, 0.96-2.65-micron spectrophotometry for the Pluto-Charon system indicates night-to-night variations in the depths of the methane absorptions such that the bands' equivalent width is near minimum light. The interpretation of these data in terms of a depletion of methane in dark regions of the planet, relative to bright ones, is consistent with the Buie and Fink (1987) observations. The near-IR spectrum of Pluto seems to be dominated by surface frost. It is suggested that the dark equatorial regions of Pluto are redder than those of moderate albedo.

  13. The nature of C-class asteroids from 3-micron spectrophotometry

    Science.gov (United States)

    Feierberg, M. A.; Lebofsky, L. A.; Tholen, D. J.

    1985-01-01

    Narrowband spectrophotometry between 2.3 and 3.5 micrometers is presented for 14 main-belt C asteroids greater than 100 km in diameter. Absorption features at 3 micrometers due to water of hydration are present in the spectra of nine of the asteroids, with intensities ranging from 6 to 23 percent. The other five asteroids have no such absorption greater than 2 percent in intensity. The present C-asteroid population may be fragments of larger parent bodies with anhydrous C3-like cores and hydrated C1I- or C2M-like mantles.

  14. Determination of uranium and plutonium in high active solutions by extractive spectrophotometry

    International Nuclear Information System (INIS)

    Subba Rao, R.V.; Damodaran, K.; Santosh Kumar, G.; Ravi, T.N.

    2000-01-01

    Plutonium and uranium was extracted from nitric acid into trioctyl phosphine oxide in xylene. The TOPO layer was analysed by spectrophotometry. Thoron was used as the chromogenic agent for plutonium. Pyridyl azoresorcinol was used as chromogenic agent for uranium. The molar absorption coefficient for uranium and plutonium was found to be 19000 and 19264 liter/mole-cm, respectively. The correlation coefficient for plutonium and uranium was found to be 0.9994. The relative standard deviation for the determination of plutonium and uranium was found to be 0.96% and 1.4%, respectively. (author)

  15. The spectrophotometry and chemical composition of the oxygen-poor bipolar nebula NGC 6164-5

    Science.gov (United States)

    Dufour, Reginald J.; Parker, Robert A. R.; Henize, Karl G.

    1988-01-01

    The paper presents new ground-based and IUE spectrophotometry of several positions in NGC 6164-5 surrounding the Population I Of star HD 148937. Electron temperatures, densities, and abundances are derived for the various positions in the nebula using spectral line information. For all of the regions observed, Ne/H is depleted by an amount comparable to O/H, while S/H and Ar/H have normal values. The results suggest that the nebula consists partly of material ejected from inner shell-burning regions of the Of star. In effect, HD 148937 is older and more advanced than what was previously thought.

  16. Thin film thickness measurement error reduction by wavelength selection in spectrophotometry

    International Nuclear Information System (INIS)

    Tsepulin, Vladimir G; Perchik, Alexey V; Tolstoguzov, Victor L; Karasik, Valeriy E

    2015-01-01

    Fast and accurate volumetric profilometry of thin film structures is an important problem in the electronic visual display industry. We propose to use spectrophotometry with a limited number of working wavelengths to achieve high-speed control and an approach to selecting the optimal working wavelengths to reduce the thickness measurement error. A simple expression for error estimation is presented and tested using a Monte Carlo simulation. The experimental setup is designed to confirm the stability of film thickness determination using a limited number of wavelengths

  17. Spectrophotometry and chemical composition of the oxygen-poor bipolar nebula NGC 6164-5

    International Nuclear Information System (INIS)

    Dufour, R.J.; Parker, R.A.R.; Henize, K.G.

    1988-01-01

    The paper presents new ground-based and IUE spectrophotometry of several positions in NGC 6164-5 surrounding the Population I Of star HD 148937. Electron temperatures, densities, and abundances are derived for the various positions in the nebula using spectral line information. For all of the regions observed, Ne/H is depleted by an amount comparable to O/H, while S/H and Ar/H have normal values. The results suggest that the nebula consists partly of material ejected from inner shell-burning regions of the Of star. In effect, HD 148937 is older and more advanced than what was previously thought. 34 references

  18. Determination of traces of silver in waters by anion exchange and atomic absorption spectrophotometry

    Science.gov (United States)

    Chao, T.T.; Fishman, M. J.; Ball, J.W.

    1969-01-01

    A method has been developed for the accurate determination of 0.1-1 ??g of silver per liter of water. The method permits stabilization of silver in water without loss to container walls. Optimum conditions have been established for the complete recovery of silver from water with an anion-exchange column, for quantitative elution of silver from the resin, and for measurement of silver by atomic absorption spectrophotometry after chelation with ammonium pyrrolidine dithiocarbamate and extraction of the chelate with MIBK. Silver in the 1-10 ??g 1 range can be determined by extraction without pre-concentration on an ion-exchange resin. ?? 1969.

  19. Determination of Ca, Cu, Fe and Pb in sugarcane raw spirits by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Lorenzo, Magdalena; Reyes, Arlyn; Blanco, Idania; Vasallo, Maria C

    2010-01-01

    The determination of Ca, Cu, Fe and Pb in sugarcane raw spirits by atomic absorption spectrophotometry was carried out. For 20 μL injected sample, calibration within the 0,5-25,0 mg. L -1 Ca; 0,25-5,0 mg. L -1 Cu, Pb and Cu intervals were established using the ratios Cu, Ca, Fe and Pb absorbance versus analyte concentration, respectively. Typical linear correlations of r = 0,999 were obtained. The proposed method was applied for the direct determination of Ca, Cu, Fe and Pb in sugar cane spirits, and in samples. The results obtained were in accordance to those obtained at 95% confidence level

  20. Determination of silica in silicates by differential spectrophotometry as α-molybdosilicic acid

    International Nuclear Information System (INIS)

    Ohlweiler, O.A.; Meditsch, J.O.; Silva, S.

    1980-01-01

    A method for determining silica in silicates by differential spectrophotometry, using β-molybdosilic acid, is described. The sample is attacked by a mixture of boron trioxide and lithium carbonate (10:1). α-molydbosilicic acid is developed in a buffered solution (pH approximatelly 3.9) containing acetic acid and sodium acetate. The analytical procedure involves a series of preliminary steps which were previously elaborated for the gravimetric determination of silica as oxine molybdosilicate and which account for the removal of phosphorus, titanium and zirconium through ion exchange resins. (C.L.B.) [pt

  1. Symbiotic stars: spectrophotometry at 3-4 and 8-13 μm

    International Nuclear Information System (INIS)

    Roche, P.F.; Aitken, D.K.

    1983-01-01

    Infrared spectrophotometry of 20 symbiotic stars, mostly of dust-rich variety, is presented. HDE 330036 is unique in showing an emission feature at 11.3 μm. The remainder combine a hot grey component and/or optically thin silicate emission. A model in which the grey component is due to optically thick silicate dust is not consistent with the spectra. It is proposed instead that iron-based grains, expected to form in the ejecta of cool stars, are heated by the ultraviolet radiation field of the hot companion. (author)

  2. REVIEW ARTICLE: Spectrophotometric applications of digital signal processing

    Science.gov (United States)

    Morawski, Roman Z.

    2006-09-01

    Spectrophotometry is more and more often the method of choice not only in analysis of (bio)chemical substances, but also in the identification of physical properties of various objects and their classification. The applications of spectrophotometry include such diversified tasks as monitoring of optical telecommunications links, assessment of eating quality of food, forensic classification of papers, biometric identification of individuals, detection of insect infestation of seeds and classification of textiles. In all those applications, large numbers of data, generated by spectrophotometers, are processed by various digital means in order to extract measurement information. The main objective of this paper is to review the state-of-the-art methodology for digital signal processing (DSP) when applied to data provided by spectrophotometric transducers and spectrophotometers. First, a general methodology of DSP applications in spectrophotometry, based on DSP-oriented models of spectrophotometric data, is outlined. Then, the most important classes of DSP methods for processing spectrophotometric data—the methods for DSP-aided calibration of spectrophotometric instrumentation, the methods for the estimation of spectra on the basis of spectrophotometric data, the methods for the estimation of spectrum-related measurands on the basis of spectrophotometric data—are presented. Finally, the methods for preprocessing and postprocessing of spectrophotometric data are overviewed. Throughout the review, the applications of DSP are illustrated with numerous examples related to broadly understood spectrophotometry.

  3. On Reflection

    DEFF Research Database (Denmark)

    Blasco, Maribel

    2012-01-01

    produces: that the self is accessible and transcendable, that reflexivity is universal across space and time, and that the self can act as its own remedial change agent or ‘inner consultant.’ I argue that because reflexivity is understood in many different ways, attention to definition is crucial, both...... on the concepts of selfhood that prevail and how notions of difference are constructed. First, I discuss how the dominant usages of reflexivity in intercultural education reflect and reproduce a Cartesian view of the self that shapes how ICC is conceptualized and taught. I discuss three assumptions that this view...

  4. Inspiring Reflections

    DEFF Research Database (Denmark)

    Muchie, Mammo

    2011-01-01

    A numberof Chris Freeman's colleagues were asked to reflect on what they thought describes his life and work in a few words. Some of the colleagues replied including former SPRU students that were taught or supervised by Chris Freeman. Their views on what they thought were Chris Freeman's defining...... life is not free from fluctuations, cycles, disruptions, crises and destructions both human and ecological. Innovation research ought to position itself to address environmental, financial and economic crises. The third is innovation research for development by addressing not only poverty erdaication...

  5. Reflective Writing

    DEFF Research Database (Denmark)

    Ahrenkiel Jørgensen, Andriette

    2016-01-01

    In Breve fra min Have (Letters from my Garden), the Swedish landscape architect, Sven-Ingvar Andersson, produces dialogues about his garden to a wide circle of friends, colleagues, deceased and still living acquaintances such as Karen Blixen, Gertrude Stein, C. Th. Sørensen, Albrecht Dürer, Peter...... Høeg etetera. The dialogues work as a tool of reflection in terms of providing opportunity to examine his own beliefs, to explore the possible reasons for engaging in a particular activity. On the basis of Sven-Ingvar Andersson’s book a teaching program at the Aarhus School of Architecture provides...

  6. Reflective Packaging

    Science.gov (United States)

    1994-01-01

    The aluminized polymer film used in spacecraft as a radiation barrier to protect both astronauts and delicate instruments has led to a number of spinoff applications. Among them are aluminized shipping bags, food cart covers and medical bags. Radiant Technologies purchases component materials and assembles a barrier made of layers of aluminized foil. The packaging reflects outside heat away from the product inside the container. The company is developing new aluminized lines, express mailers, large shipping bags, gel packs and insulated panels for the building industry.

  7. Spectrophotometric and potentiometric study of uranyl hydrolysis in perchlorate medium. Is derivative spectrophotometry suitable for search of the chemical model?

    International Nuclear Information System (INIS)

    Lubal, P.; Havel, J.

    1997-01-01

    Uranyl hydrolysis (I = 3.00 mol dm -3 NaClO 4 , T = 298.15 K) was studied by potentiometry and spectrophotometry. Numerical analysis of experimental data yielded the logarithmic values of hydrolytic constants for (UO 2 ) p (OH) q (2p-q) species with (p, q) indices: (2, 2) - 6.24 ± 0.02, (3, 5) - 16.80 ± 0.04, and (3, 4) - 12.8 ± 0.1 (potentiometry) and (2, 2) - 6.13 ± 0.02, (3, 5) - 16.81 ± 0.02, and (32, 4) - 12.57 ± 0.02 (average values obtained by derivative spectrophotometry from the first to the fourth order). The spectra of hydrolytic species were deconvoluted and the use of derivative spectrophotometry in equilibria studies has been discussed. (authors)

  8. Neutron reflectivity

    Directory of Open Access Journals (Sweden)

    Cousin Fabrice

    2015-01-01

    Full Text Available The specular neutron reflectivity is a technique enabling the measurement of neutron scattering length density profile perpendicular to the plane of a surface or an interface, and thereby the profile of chemical composition. The characteristic sizes that are probed range from around 5 Å up 5000 Å. It is a scattering technique that averages information on the entire surface and it is therefore not possible to obtain information within the plane of the interface. The specific properties of neutrons (possibility of tuning the contrast by isotopic substitution, sensitivity to magnetism, negligible absorption, low energy of the incident neutrons makes it particularly interesting in the fields of soft matter, biophysics and magnetic thin films. This course is a basic introduction to the technique and does not address the magnetic reflectivity. It is composed of three parts describing respectively its principle and its formalism, the experimental aspects of the method (spectrometers, samples and two examples related to the materials for energy.

  9. Infrared spectrophotometry and radiative transfer in optically thick circumstellar dust envelopes

    International Nuclear Information System (INIS)

    Merrill, K.M.

    1976-01-01

    The Two-Micron Sky Survey of Neugebauer and Leighton and, more recently, the AFCRL Infrared Sky Survey of Walker and Price have detected numerous compact, isolated, bright infrared sources which are not identified with previously cataloged stars. Observations of many such objects suggest that extensive circumstellar dust envelopes modify the flux from a central source. The present investigations employ broad bandpass photometry at lambda lambda 1.65 μm to 12.5 μm and narrow bandpass spectrophotometry (Δ lambda/lambda approximately 0.015) at lambda lambda 2-4 μm and lambda lambda 8-13 μm to determine the properties of a large sample of such infrared sources. Infrared spectrophotometry can clearly differentiate between normal stars of spectral types M(''oxygen-rich'') and C (''carbon-rich'') on the basis of characteristic absorption bands arising in cool stellar atmospheres. Most of the 2 μ Sky Survey and many of the AFCRL Sky Survey sources appear to be stars of spectral types M and C which are differentiated from normal cool comparison stars only by the presence of extensive circumstellar dust envelopes. Due to the large optical depth of the envelopes, the flux from the star and from the dust cannot be simply separated. Hence solutions of radiative transfer through spherically symmetric envelopes of arbitrary optical depth were generated by a generalized computer code which employed opacities of real dust

  10. Chemometrics-assisted spectrophotometry method for the determination of chemical oxygen demand in pulping effluent.

    Science.gov (United States)

    Chen, Honglei; Chen, Yuancai; Zhan, Huaiyu; Fu, Shiyu

    2011-04-01

    A new method has been developed for the determination of chemical oxygen demand (COD) in pulping effluent using chemometrics-assisted spectrophotometry. Two calibration models were established by inducing UV-visible spectroscopy (model 1) and derivative spectroscopy (model 2), combined with the chemometrics software Smica-P. Correlation coefficients of the two models are 0.9954 (model 1) and 0.9963 (model 2) when COD of samples is in the range of 0 to 405 mg/L. Sensitivities of the two models are 0.0061 (model 1) and 0.0056 (model 2) and method detection limits are 2.02-2.45 mg/L (model 1) and 2.13-2.51 mg/L (model 2). Validation experiment showed that the average standard deviation of model 2 was 1.11 and that of model 1 was 1.54. Similarly, average relative error of model 2 (4.25%) was lower than model 1 (5.00%), which indicated that the predictability of model 2 was better than that of model 1. Chemometrics-assisted spectrophotometry method did not need chemical reagents and digestion which were required in the conventional methods, and the testing time of the new method was significantly shorter than the conventional ones. The proposed method can be used to measure COD in pulping effluent as an environmentally friendly approach with satisfactory results.

  11. The Assessment of Liver Reserve Function by Spectrophotometry based on Determination of Phenacetin and Paracetamol.

    Science.gov (United States)

    Ren, Rui; Ma, Yongmei; Ma, Wanshan; Lu, Sumei

    2015-01-01

    To establish a technical system for assessing liver reserve function based on spectrophotometry by detection of phenacetin and paracetamol in blood samples. Taking detected contents of phenacetin and paracetamol by high performance liquid chromatography (HPLC) as standard, which was proved to be able to detect drug concentrations with high resolution and accuracy, we established a technical system based on the spectrophotometric technique to assay phenacetin and paracetamol, including the color system, the maximum absorption wavelength, the influence factors of color system, and the optimal conditions for hydrolysis. Then we verified our established system compared with that under HPLC by recovery test. This study established a technical system to detect phenacetin and paracetamol in blood samples using spectrophotometry. Mainly, 3 mol/L hydrochloric acid (HCl) was added to samples for hydrolysis for 30 minutes, then, adding 0.02% 1,2-naphthoquinone-4-sulfonate (NQS), 1% cetyltrimethyl ammonium bromide (CTA) and 2% sodium hydroxide (or 3% sodium carbonate) (ratio of 1:6:1:2 or 3), and the absorbance was measured at 500 nm and 570 nm to calculate their concentrations. Using an established spectrophotometric system to detect phenacetin and paracetamol in blood samples could assess liver reserve function, which was proved comparable with HPLC in resolution and repeatability.

  12. Optical properties of orthodontic aligners--spectrophotometry analysis of three types before and after aging.

    Science.gov (United States)

    Lombardo, Luca; Arreghini, Angela; Maccarrone, Roberta; Bianchi, Anna; Scalia, Santo; Siciliani, Giuseppe

    2015-01-01

    The aim was to assess and compare absorbance and transmittance values of three types of clear orthodontic aligners before and after two cycles of in vitro aging. Nine samples of orthodontic aligners from three different manufacturers (Invisalign, Align Technology, Santa Clara, CA, USA; All-In, Micerium, Avegno, GE, Italy; F22 Aligner, Sweden & Martina, Due Carrare, PD, Italy) were selected, and each sample was subjected to spectrophotometry analysis of both its transmittance and absorbance a total of 27 times. Samples were subsequently aged in vitro at a constant temperature in artificial saliva supplemented with food colouring for two cycles of 14 days each. The spectrophotometry protocol was then repeated, and the resulting data were analysed and compared by means of ANOVA (p < 0.05). All types of aligners tested yielded lower transmittance and higher absorbance values after aging, but the difference was not significant in any case. That being said, the F22 aligners were found to be most transparent, both before and after aging, followed by Invisalign and All-In, and these differences were statistically significant. Commercial aligners possess significantly different optical, and therefore aesthetic, properties, both as delivered and following aging.

  13. Reflected Glory

    Science.gov (United States)

    2011-02-01

    The nebula Messier 78 takes centre stage in this image taken with the Wide Field Imager on the MPG/ESO 2.2-metre telescope at the La Silla Observatory in Chile, while the stars powering the bright display take a backseat. The brilliant starlight ricochets off dust particles in the nebula, illuminating it with scattered blue light. Igor Chekalin was the overall winner of ESO's Hidden Treasures 2010 astrophotography competition with his image of this stunning object. Messier 78 is a fine example of a reflection nebula. The ultraviolet radiation from the stars that illuminate it is not intense enough to ionise the gas to make it glow - its dust particles simply reflect the starlight that falls on them. Despite this, Messier 78 can easily be observed with a small telescope, being one of the brightest reflection nebulae in the sky. It lies about 1350 light-years away in the constellation of Orion (The Hunter) and can be found northeast of the easternmost star of Orion's belt. This new image of Messier 78 from the MPG/ESO 2.2-metre telescope at the La Silla Observatory is based on data selected by Igor Chekalin in his winning entry to the Hidden Treasures competition [1]. The pale blue tint seen in the nebula in this picture is an accurate representation of its dominant colour. Blue hues are commonly seen in reflection nebulae because of the way the starlight is scattered by the tiny dust particles that they contain: the shorter wavelength of blue light is scattered more efficiently than the longer wavelength red light. This image contains many other striking features apart from the glowing nebula. A thick band of obscuring dust stretches across the image from the upper left to the lower right, blocking the light from background stars. In the bottom right corner, many curious pink structures are also visible, which are created by jets of material being ejected from stars that have recently formed and are still buried deep in dust clouds. Two bright stars, HD 38563A and

  14. The dynamics of color signals in male threespine sticklebacks Gasterosteus aculeatus.

    Science.gov (United States)

    Hiermes, Meike; Rick, Ingolf P; Mehlis, Marion; Bakker, Theo C M

    2016-02-01

    Body coloration and color patterns are ubiquitous throughout the animal kingdom and vary between and within species. Recent studies have dealt with individual dynamics of various aspects of coloration, as it is in many cases a flexible trait and changes in color expression may be context-dependent. During the reproductive phase, temporal changes of coloration in the visible spectral range (400-700 nm) have been shown for many animals but corresponding changes in the ultraviolet (UV) waveband (300-400 nm) have rarely been studied. Threespine stickleback Gasterosteus aculeatus males develop conspicuous orange-red breeding coloration combined with UV reflectance in the cheek region. We investigated dynamics of color patterns including UV throughout a male breeding cycle, as well as short-term changes in coloration in response to a computer-animated rival using reflectance spectrophotometry and visual modeling, to estimate how colors would be perceived by conspecifics. We found the orange-red component of coloration to vary during the breeding cycle with respect to hue ( theta /R50) and intensity (achieved chroma/red chroma). Furthermore, color intensity in the orange-red spectral part (achieved chroma) tended to be increased after the presentation of an artificial rival. Dynamic changes in specific measures of hue and intensity in the UV waveband were not found. In general, the orange-red component of the signal seems to be dynamic with respect to color intensity and hue. This accounts in particular for color changes during the breeding cycle, presumably to signal reproductive status, and with limitations as well in the intrasexual context, most likely to signal dominance or inferiority.

  15. Determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations using derivative spectrophotometry and chromatographic-densitometric method.

    Science.gov (United States)

    Stolarczyk, Mariusz; Maślanka, Anna; Apola, Anna; Krzek, Jan

    2013-01-01

    Two methods, spectrophotometric and chromatographic-densitometric ones, were developed for determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations. Spectrophotometric method involved derivative spectrophotometry and zero order spectrophotometry. The measurements were carried out at lambda = 224.0 nm for quinapril, lambda = 261.0 nm for hydrochlorothiazide and lambda = 270.0 nm for losartan when the derivative spectrophotometry was applied and lambda = 317.0 nm when zero order spectrophotometry was applied for the determination of hydrochlorothiazide. In chromatographic-densitometric studies high performance thin layer chromatography (HPTLC) plates were used as stationary phase and a mixture of solvents n-butanol : acetic acid : water (15 : 5 : 1, v/v/v) as mobile phase. Under the established conditions good resolution of examined constituents was obtained. Retardation factor for quinapril hydrochloride was R(f) - 0.70, for losartan potassium R(f) - 0.85 and for hydrochlorothiazide R(f) - 0.78. The developed methods are characterized by high sensitivity and accuracy. For quantitative analysis, densitometric measurements were carried out at lambda = 218.0 nm for quinapril, lambda = 275.0 nm for hydrochlorothiazide and = 232.0 nm for losartan.

  16. On line spectrophotometry with optical fibers. Application to uranium-plutonium separation in a spent fuel reprocessing plant

    International Nuclear Information System (INIS)

    Boisde, G.; Mus, G.; Tachon, M.

    1985-06-01

    Optimization of mixer-settler operation for uranium-plutonium separation in the Purex process can be obtained by remote spectrophotometry with optical fibers. Data acquisition on uranium VI, uranium IV and plutonium III is examined in function of acidity and nitrate content of the solution. Principles for on line multicomponent monitoring and mathematical modelization of the measurements are described [fr

  17. Ultraviolet reflectance by the cere of raptors

    Science.gov (United States)

    Mougeot, François; Arroyo, Beatriz E

    2006-01-01

    Ultraviolet (UV) signals have been shown to play key roles in social and sexual signalling in birds. Using a spectrophotometer, we analysed the colour of the cere (skin above the beak) of a diurnal raptor, the Montagu's harrier (Circus pygargus), and show that it reflects in the UV part of the spectrum. The cere is a well-known sexual signal in raptors, with carotenoid based pigmentation being indicative of quality. We thus hypothesized that UV reflectance also signals quality. Accordingly, we found that in our sample of wild males, the location of the UV peak was related to the orangeness of cere and correlated with male body mass and condition (mass corrected for size). Also, males with brighter UV were mated to females that laid earlier, as expected if UV reflectance relates to a male's quality and attractiveness. Future studies should investigate the relationships between UV reflectance and carotenoid pigmentation of cere, and test how UV reflectance influences mate choice. PMID:17148356

  18. Spectrophotometry of Wolf-Rayet stars - Intrinsic colors and absolute magnitudes

    Science.gov (United States)

    Torres-Dodgen, Ana V.; Massey, Philip

    1988-01-01

    Absolute spectrophotometry of about 10-A resolution in the range 3400-7300 A have been obtained for southern Wolf-Rayet stars, and line-free magnitudes and colors have been constructed. The emission-line contamination in the narrow-band ubvr systems of Westerlund (1966) and Smith (1968) is shown to be small for most WN stars, but to be quite significant for WC stars. It is suggested that the more severe differences in intrinsic color from star to star of the same spectral subtype noted at shorter wavelengths are due to differences in atmospheric extent. True continuum absolute visual magnitudes and intrinsic colors are obtained for the LMC WR stars. The most visually luminous WN6-WN7 stars are found to be located in the core of the 30 Doradus region.

  19. Far-ultraviolet and optical spectrophotometry of X-ray selected Seyfert galaxies

    International Nuclear Information System (INIS)

    Clarke, J.T.; Bowyer, S.; Grewing, M.; California Univ., Berkeley; Tuebingen Universitaet, West Germany)

    1986-01-01

    Five X-ray selected Seyfert galaxies were examined via near-simultaneous far-ultraviolet and optical spectrophotometry in an effort to test models for excitation of emission lines by X-ray and ultraviolet continuum photoionization. The observed Ly-alpha/H-beta ratio in the present sample averages 22, with an increase found toward the high-velocity wings of the H lines in the spectrum of at least one of the Seyfert I nuclei. It is suggested that Seyfert galaxies with the most high-velocity gas exhibit the highest Ly-alpha/H-beta ratios at all velocities in the line profiles, and that sometimes this ratio may be highest for the highest velocity material in the broad-line clouds. Since broad-lined objects are least affected by Ly-alpha trapping effects, they have Ly-alpha/H-beta ratios much closer to those predicted by early photoionization calculations. 21 references

  20. Ultraviolet spectrophotometry of comet Giacobini-Zinner during the ICE encounter. [International Cometary Explorer (ICE)

    Science.gov (United States)

    Ahearn, Michael F.; Mcfadden, Lucy A.; Feldman, Paul D.; Boehnhardt, Hermann; Rahe, Juergen; Festou, Michael; Brandt, John C.; Maran, Stephen P.; Niedner, Malcom B.; Smith, Andrew M.

    1986-01-01

    The IUE spectrophotometry of Comet P/Giacobini-Zinner was acquired in support of the International Cometary Explorer (ICE) mission. The abundances (or upper limits) of UV-active species were calculated. During the ICE encounter the H2O production rate was 3 times 10 to the 28th power/sec, + or - 50%, consistent with values derived from the ICE experiments. Comparison of the abundance of CO2(+) ions with the total electron density measured by the plasma electron experiment on ICE indicates a deficiency of ions relative to electrons indicating a population of ions not detected by remote sensing. The absence of detectable Mg(+) rules out this species as a possible ion of M/Q = 24 detected by the Ion Composition Instrument, part of the ICE complement of instruments.

  1. Neutron activation analysis and atomic absorption spectrophotometry for the analysis of fresh, pasteurised and powder milk

    International Nuclear Information System (INIS)

    Wasim, M.; Rehman, S.; Arif, M.; Fatima, I.; Zaidi, J.H.

    2012-01-01

    This study shows the application of semi-absolute k 0 instrumental neutron activation analysis (k 0 -INAA), epithermal neutron activation analysis (ENAA) and atomic absorption spectrophotometry (AAS) for the determination of 21 elements (Br, Ca, Cl, Co, Cr, Cs, Cu, Fe, Hf, I, K, Mg, Mn, Na, Ni, P, Pb, Rb, Sc Sr, and Zn) in different types of milk samples. The ENAA was required for the determination of iodine, AAS for Cu, Ni and Pb and the rest of the elements were measured by k 0 -INAA. Thirteen elements (Br, Ca, Cl, Cs, Cu, Fe, K, Mg, Na, P, Rb, Sr and Zn) were identified in all milk samples. Ni was detected in eleven and Pb in two samples. Concentrations of most of the elements were within the ranges of the world reported data. The data was further explored by principal component analysis to find relationships between samples and elements. (orig.)

  2. Determination of radial peculiar velocities of galaxy clusters by means of the submillimeter spectrophotometry

    International Nuclear Information System (INIS)

    Sholomitskij, G.B.

    1984-01-01

    The possibility is considered to obtain from the extraatmospheric submillimeter spectrophotometry of galaxy clusters the ratios vsub(r)/Tsub(e) for clusters intergalactic gas that permits, together with the X-ray measurements of electronic temperature Tsub(e) in the case of hot scattering gas to determine absolute radial peculiar velocities vsub(r) of galaxy clusters relative to the relic radiation. By simulating such peculiar velocities as an example for the system of bandpass filters in the wavelength range 300 μm - 2 mm the accuracy of vsub(r) estimates is proved to be about 300 km/s (not taking into account the errors in Tsub(e)) the sensitivity of deeply cooled submillimeter bolometers being 1x10 -15 W/Hzsup(1/2)

  3. Spatially Multiplexed Micro-Spectrophotometry in Bright Field Mode for Thin Film Characterization

    Directory of Open Access Journals (Sweden)

    Valerio Pini

    2016-06-01

    Full Text Available Thickness characterization of thin films is of primary importance in a variety of nanotechnology applications, either in the semiconductor industry, quality control in nanofabrication processes or engineering of nanoelectromechanical systems (NEMS because small thickness variability can strongly compromise the device performance. Here, we present an alternative optical method in bright field mode called Spatially Multiplexed Micro-Spectrophotometry that allows rapid and non-destructive characterization of thin films over areas of mm2 and with 1 μm of lateral resolution. We demonstrate an accuracy of 0.1% in the thickness characterization through measurements performed on four microcantilevers that expand an area of 1.8 mm2 in one minute of analysis time. The measured thickness variation in the range of few tens of nm translates into a mechanical variability that produces an error of up to 2% in the response of the studied devices when they are used to measure surface stress variations.

  4. A Research on Determination of Lecithin in Eggs by Applying Microwave Digestion Techniques and Spectrophotometry

    International Nuclear Information System (INIS)

    Wu, M.; Ge, Q.L.; Gao, Y. Sh.; Chen, K. W.

    2012-01-01

    A method to quick detect concentration of lecithin in eggs, namely microwave digestion spectrophotometry, was established in this research. The homogenate of eggs was treated with absolute ethanol to eliminate phosphate protein in eggs which could possibly affect concentration of lecithin examined. A sample then received a new way of pre-treatment, called microwave digestion, before UV-Vis spectrometry was applied to examine the concentration of phosphate at 400 nm. The linear equation was A = 0.08628X (μg), the corresponding coefficient of correlation was 0.9998, the detection limit of phosphorous was 0.2μg (n=11). The content of lecithin in eggs was then obtained. According to the result, the recovery of 90% was secured; therefore the conclusion of high degree of accuracy was reached.

  5. Removal of iron interferences by solvent extraction for geochemical analysis by atomic-absorption spectrophotometry

    Science.gov (United States)

    Zhou, L.; Chao, T.T.; Sanzolone, R.F.

    1985-01-01

    Iron is a common interferent in the determination of many elements in geochemical samples. Two approaches for its removal have been taken. The first involves removal of iron by extraction with methyl isobutyl ketone (MIBK) from hydrochloric acid medium, leaving the analytes in the aqueous phase. The second consists of reduction of iron(III) to iron(II) by ascorbic acid to minimize its extraction into MIBK, so that the analytes may be isolated by extraction. Elements of interest can then be determined using the aqueous solution or the organic extract, as appropriate. Operating factors such as the concentration of hydrochloric acid, amounts of iron present, number of extractions, the presence or absence of a salting-out agent, and the optimum ratio of ascorbic acid to iron have been determined. These factors have general applications in geochemical analysis by atomic-absorption spectrophotometry. ?? 1985.

  6. Alternative set of conditions for molybdenum determination by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Edgar, R.M.

    1975-01-01

    In comparing a newly developed procedure with that recommended by Perkin--Elmer, et al., (Analytical Methods for Atomic Absorption Spectrophotometry, Perkin--Elmer Corp., Norwalk, Conn. 1973) two areas were found in which the new procedure appeared more suitable for Mo determination. If Cr is present in concentrations greater than 100 ppM, the recommended procedure results in an enhancement effect on Mo absorption. This erroneously high result is eliminated when the new procedure is followed. In the recommended procedure, when the sample has to be dissolved in hydrofluoric acid and Al is added to help eliminate interferences, the acid combines with the Al to form insoluble aluminum fluoride. The part that Al plays in eliminating interferences is lessened, because it is no longer in solution

  7. Can the Assessment of Spontaneous Oscillations by Near Infrared Spectrophotometry Predict Neurological Outcome of Preterm Infants?

    Science.gov (United States)

    Stammwitz, André; von Siebenthal, Kurt; Bucher, Hans U; Wolf, Martin

    2016-01-01

    The aim was to assess the correlation between cerebral autoregulation and outcome. Included were 31 preterm infants, gestational age 26 1/7 to 32 2/7 and <24 h life. Coherence between cerebral total haemoglobin (tHb) or oxygenation index (OI) measured by near-infrared spectrophotometry (NIRS) and systemic heart rate (HR) or arterial blood pressure (MAP) was calculated as a measure of autoregulation. In contrast to previous studies, low coherences in the first 24 h were significantly associated with intraventricular haemorrhage, death or abnormal neurodevelopmental outcome at 18 months or later. We suggest that our results can be explained by the concept of a multi-oscillatory-functions-order.

  8. A high-throughput screening strategy for nitrile-hydrolyzing enzymes based on ferric hydroxamate spectrophotometry.

    Science.gov (United States)

    He, Yu-Cai; Ma, Cui-Luan; Xu, Jian-He; Zhou, Li

    2011-02-01

    Nitrile-hydrolyzing enzymes (nitrilase or nitrile hydratase/amidase) have been widely used in the pharmaceutical industry for the production of carboxylic acids and their derivatives, and it is important to build a method for screening for nitrile-hydrolyzing enzymes. In this paper, a simple, rapid, and high-throughput screening method based on the ferric hydroxamate spectrophotometry has been proposed. To validate the accuracy of this screening strategy, the nitrilases from Rhodococcus erythropolis CGMCC 1.2362 and Alcaligenes sp. ECU0401 were used for evaluating the method. As a result, the accuracy for assaying aliphatic and aromatic carboxylic acids was as high as the HPLC-based method. Therefore, the method may be potentially used in the selection of microorganisms or engineered proteins with nitrile-hydrolyzing enzymes.

  9. Determination of glucosinolates in 19 Chinese medicinal plants with spectrophotometry and high-pressure liquid chromatography.

    Science.gov (United States)

    Hu, Ye; Liang, Hao; Yuan, Qipeng; Hong, Yuancheng

    2010-08-01

    Glucosinolates were evaluated in 19 traditional Chinese medicinal plants involved in seven different families: Brassicaceae, Capparaceae, Euphorbiaceae, Phytolaccaceae, Tropaeolaceae, Caricaceae and Rubiaceae. The total glucosinolate contents were determined by spectrophotometry. Results showed that the high contents of total glucosinolates were found in some herbs of Brassicaceae, Capparaceae and Euphorbiaceae families, while low total glucosinolate contents were observed in two Rubiaceae herbs. In addition, eight glucosinolates (glucoraphanin, glucoraphenin, sinalbin, sinigrin, progoitrin, 4-hydroglucobrassicin, glucoiberin and glucoibervirin) in these herbs were measured using HPLC, and the data showed that individual glucosinolates and their contents varied at different degrees among the distinct species. The highest contents of cancer-protective compounds were found in the seeds of Raphanus sativus L. (glucoraphenin), Sinapis alba (sinalbin) and Phyllanthus emblica L. (sinigrin).

  10. Application of infrared spectrophotometry to the identification of inorganic substances in dosage forms of Antacida group.

    Science.gov (United States)

    Umbreit, M H; Jedrasiewicz, A

    2000-01-01

    Powdered tablets from the Antacida group: Alusal, Milk of Magnesia, Alumag, Maalox, Magnosil, Alugastrin, Malugastrin, Rennie, and components deciding about their antiacidity like Al(OH)3, Mg(OH)2, Mg2Si3O8, NaAl(OH)2CO3, MgAl(OH)(SO4)2, CaCO3, MgCO3, were subjected to infrared spectrophotometric investigations. It was found that infrared spectra of each pharmaceutical compound are different and show a series of characteristic maxima, by which they can be identified with in the spectral range of 4000 cm-1-200 cm-1. Comparison of infrared spectra of finished products with spectra of their components it was showed that the application of infrared spectrophotometry methods enabled us to prove the presence of particular compounds used in formulations. Tablet mass and odorizing agents do not cause significant changes in spectra of the tablets studied, preparations from the Antacida group.

  11. Simultaneous Determination of Cobalt (II and Nickel (II By First Order Derivative Spectrophotometry in Micellar Media

    Directory of Open Access Journals (Sweden)

    Rajni Rohilla

    2012-01-01

    Full Text Available A first-derivative spectrophotometry method for the simultaneous determination of Co (II and Ni (II with Alizarin Red S in presence of Triton X-100 is described. Measurements were made at the zero-crossing wavelengths at 549.0 nm for Co (II and 546.0 nm for Ni (II. The linearity is obtained in the range of 0.291- 4.676 μg/ml of Ni (II and 0.293- 4.124 μg/ml of Co (II in the presence of each other by using first derivative spectrophotometric method. The possible interfering effects of various ions were studied. The validity of the method was examined by using synthetic mixtures of Co (II and Ni (II. The developed derivative procedure, using the zero crossing technique, has been successfully applied for the simultaneous analysis of Co (II and Ni (II in spiked water samples.

  12. Sensitivity and accuracy of atomic absorption spectrophotometry for trace elements in marine biological samples

    International Nuclear Information System (INIS)

    Fukai, R.; Oregioni, B.

    1976-01-01

    During the course of 1974-75 atomic absorption spectrophotometry (AAS) has been used extensively in our laboratory for measuring various trace elements in marine biological materials in order to conduct homogeneity tests on the intercalibration samples for trace metal analysis as well as to obtain baseline data for trace elements in various kinds of marine organisms collected from different locations in the Mediterranean Sea. Several series of test experiments have been conducted on the current methodology in use in our laboratory to ensure satisfactory analytical performance in measuring a number of trace elements for which analytical problems have not completely been solved. Sensitivities of the techniques used were repeatedly checked for various elements and the accuracy of the analyses were always critically evaluated by analyzing standard reference materials. The results of these test experiments have uncovered critical points relevant to the application of the AAS to routine analysis

  13. Net Analyte Signal Standard Additions Method for Simultaneous Determination of Sulfamethoxazole and Trimethoprim in Pharmaceutical Formulations and Biological Fluids

    OpenAIRE

    Givianrad, M. H.; Mohagheghian, M.

    2012-01-01

    The applicability of a novel net analyte signal standard addition method (NASSAM) to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim was verified by UV-visible spectrophotometry. The results confirmed that the net analyte signal standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. Moreover, applying the net analyte signal standard a...

  14. Spectrophotometry of peculiar B and A stars. I. On the detection of the lambda4200 and lambda5200 broad, continuum features of peculiar A stars

    International Nuclear Information System (INIS)

    Adelman, S.J.

    1979-01-01

    Photometric indices are used to study the broad, continuum features that are present in the energy distributions of many peculiar A stars and that may be indicators of the atmospheric structure. Values of Maitzen's Δa index, which is a measure of the lambda5200 feature, are synthesized from spectrophotometric data to examine the properties of this photometric system as well as to establish a preliminary criterion of presence for the feature. Many Ap stars definitely exhibit this feature, which normal main sequence stars lack. Two indices Δiota and Δiota* are calculated from spectrophotometry to measure the strength of the lambda4200 feature. About 90% of the Ap stars are found to have definite positive results based on the preliminary criterion of presence of the latter index. For the Ap stars there is a general tendency for Δa to increase with Δiota and Δiota*. This most likely reflects the tendency for most abundances to increase together in the Ap stars. The HgMn stars have systematically larger Δiota* and Δa values than the normal stars. This does not necessarily mean that they have the lambda4200 and lambda5200 features of the peculiar A stars. To study this question requires careful comparison of the energy distributions of the HgMn stars with those of other stars and with the predictions of model atmospheres

  15. Collection/concentration of trace uranium for spectrophotometric detection using activated carbon and first-derivative spectrophotometry

    International Nuclear Information System (INIS)

    El-Sayed, A.A.; Hamed, M.M.; El-Reefy, S.; Hmmad, H.A.

    2007-01-01

    The need exists for preconcentration of trace and ultratrace amounts of uranium from environmental, geological and biological samples. The adsorption of uranium on various solids is important from the purification, environmental, and radioactivity waste disposal points of view. A method is described for the determination of traces of uranium using first-derivative spectrophotometry after adsorptive preconcentration of uranium on activated carbon. Various parameters that influence the adsorptive preconcentration of uranium on activated carbon, viz., pH, amounts of activated carbon and time of stirring and interference of metals have been studied. First-derivative spectrophotometry in conjunction with adsorptive preconcentration of uranium on activated carbon is used for determining uranium at concentration levels down to 20 ppb (w/v). (orig.)

  16. Detection of silver nanoparticles in seawater at ppb levels using UV-visible spectrophotometry with long path cells.

    Science.gov (United States)

    Lodeiro, Pablo; Achterberg, Eric P; El-Shahawi, Mohammad S

    2017-03-01

    Silver nanoparticles (AgNPs) are emerging contaminants that are difficult to detect in natural waters. UV-visible spectrophotometry is a simple technique that allows detection of AgNPs through analysis of their characteristic surface plasmon resonance band. The detection limit for nanoparticles using up to 10cm path length cuvettes with UV-visible spectrophotometry is in the 0.1-10ppm range. This detection limit is insufficiently low to observe AgNPs in natural environments. Here we show how the use of capillary cells with an optical path length up to 200cm, forms an excellent technique for rapid detection and quantification of non-aggregated AgNPs at ppb concentrations in complex natural matrices such as seawater. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. 8-13 μm spectrophotometry of V1016 Cyg and the shape of the 'silicate' feature

    International Nuclear Information System (INIS)

    Aitken, D.K.; Roche, P.F.; Spenser, P.M.

    1980-01-01

    8 to 13μm spectrophotometry of V1016 Cyg shows a broad emission feature attributed to radiation from silicate grains. This emission feature more closely resembles that of the circumstellar shells of oxygen-rich supergiants than the more dilute feature, typical of the interstellar medium, which is observed from the Trapezium source in the Orion nebula. It appears to be possible to distinguish the evolutionary status of an object from the form of its silicate excess. (author)

  18. Europium determination in oxide and oxysulfide luminophors and their wastes by the method of direct and derivative spectrophotometry

    International Nuclear Information System (INIS)

    Mishchenko, V.T.; Aleksandrova, N.N.

    1989-01-01

    Spectrophotometric methods for europium determination in luminophors are proposed. Application of standard and derivative spectrophotometry allows one to determine europium in oxide and oxysulfide luminophors, their wastes and raffinates produced during waste reprocessing quite accurately and reliably. When determining Eu 2 O 3 (Eu 2 O 2 S) mass shares within 4-8 % limits absolute deviation from the mean result makes up to more than ± 0.2 %, relative standard deviation does not exceed 0.02

  19. Estratégias para aumento de sensibilidade em espectrofotometria UV-VIS Strategies to increase sensitivity in UV-VIS spectrophotometry

    Directory of Open Access Journals (Sweden)

    Fábio R. P. Rocha

    2004-10-01

    Full Text Available Spectrophotometry is one of the most widespread analytical techniques due to its simplicity, reliability, and low-cost instrumentation for both direct measurements and coupled to other techniques or processes such as chromatography, electrophoresis and flow analysis. However, the application is often limited by sensitivity. This article describes some advances that greatly improve the performance of spectrophotometric measurements, especially in order to increase sensitivity, including the employment of liquid-core waveguides and solid-phase spectrophotometry.

  20. A fiberoptic reflection oximeter.

    Science.gov (United States)

    Landsman, M L; Knop, N; Kwant, G; Mook, G A; Zijlstra, W G

    1978-03-20

    A catheter tip oximeter is described consisting of a cardiac catheter containing optical fibers, and incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the backscattered (reflected) light to the detection unit. The detection unit contains a dichroic mirror, transmitting most of the light with lambda less than 800 nm and reflecting most of the light with lambda greater than 900 nm, thus splitting the light into two beams. These pass through interference filters with nominal wavelengths of 640 and 920 nm respectively, and are focused on silicium barrier layer photocells. The photocell signals are amplified and fed into a divider giving the ratio of measuring (R640) and compensating (R920) photocell output. The relationship between log R640/R920 and oxygen saturation is represented by a slightly curved line. The relation may be linearized by subtracting a constant voltage from the divided output before taking the logarithm. The slope of the calibration line is dependent on the total haemoglobin concentration. Nonetheless an average calibration line can be used between 70 and 100% oxygen saturation. For 78 measurements of pig blood samples in this range (haemoglobin concentration between 96 and 161 g.1(-1)), the standard deviation of the difference between the fiberoptic oximeter and a Radiometer OSM1 oxygen saturation meter was 1.9% saturation, for 152 samples over the entire saturation range the standard deviation of the difference was 3.1% saturation. The influence of the flow velocity of blood on the light reflection depends on wavelength as well as on oxygen saturation. Therefore, complete compensation for the flow effect is not possible by simple means.

  1. Determination of mercury, lead and cadmium in water by the CRA-atomic absorption spectrophotometry with solvent extraction

    International Nuclear Information System (INIS)

    Shim, Y.B.; Won, M.S.; Kim, C.J.

    1980-01-01

    The method of CRA-atomic absorption spectrophotometer with solvent extraction for the determination of mercury, lead and cadmium in water was studied. The optimum extracting conditions for CRA-atomic absorption spectrophotometry were the following: the complexes of mercury, lead and cadmium with dithizone were separated from the aqueous solution and concentrated into the 10 ml chloroform solution. Back extraction was performed; the concentrated mercury, lead and cadmium was extracted from the chloroform solution into the 10 ml 6-normal aqueous hydrochloric acid solution. In this case, recovery ratios were the following: mercury was 94.7%, lead 97.7% and cadmium 103.6%. The optimum operating conditions for the determination of mercury, lead and cadmium by the CRA-atomic absorption spectrophotometry also were investigated to test the dry step, ash step and atomization step for each metal. The experimental results of standard addition method were the following: the determination limit of each metal within 6% relative deviation was that lead was 0.04 ppb, and cadmium 0.01 ppb. Especially, mercury has been known impossible to determine by CRA-atomic absorption spectrophotometry until now. But in this study, mercury can be determined with CRA-atomic absorption spectrophotometer. Its determination limit was 4 ppb within 8% relative deviation. (author)

  2. Comparative studies of method for determining total mercury in fish. Dithizone and flameless atomic absorption spectrophotometry techniques

    International Nuclear Information System (INIS)

    Protasowicki, M.; Ociepa, A.; Chodyniecki, A.

    1977-01-01

    Two methods for determining total mercury in fish were compared: the dithizone and flameless atomic absorption spectrophotometry techniques. The studies involved determination of recovery when 1μg of mercury as solutions of HgCl 2 or CH 3 HgC were added to each sample of herring flesh. Mean recoveries in the dithizone method were found to be 91.4+-7.47% and 90.25+-4.73% for the two solutions respectively, while the recoveries obtained with the flameless atomic absorption spectrophotometry were 95.00+-9.13% and 98.70+-7.14%, respectively. Both techniques were used to determine the mercury content in the same herring flesh sample. The first technique showed the content of 0.050+-0.018μg Hg g -1 while the result obtained with the other one was 0.062+-0.013μg Hg g -1 . The statistical treatment of the results obtained showed no difference between the two techniques, the significance level being α=0.05. Therefore, the results obtained with the dithizone method are comparable with those obtained with the flameless atomic absorption spectrophotometry for mercury contents of the magnitude order of 0.050 ug.g -1 . (author)

  3. The UV-VIS spectrophotometry applied to color and stability study in colored mortars

    Directory of Open Access Journals (Sweden)

    Alejandre, F. J.

    1999-06-01

    Full Text Available In the field of methodologies for color studying, a research of it has been done on colored mortars by applying uv-vis spectrophotometry, instrumental technique which can be used for solid materials works, and previously applied to building materials study. Results obtained show that the mentioned technique permits to evaluate quantitatively and qualitatively colors in an easy and objective way, besides nowadays advantages of the instrumental analysis: digital color register, computerized data processing, and precision and exactness increment in chromatic comparisons.

    Dentro de las metodologías existentes para el estudio del color, se ha realizado una investigación del mismo en morteros coloreados por medio de la espectrofotometría UV-VIS, técnica instrumental que es adaptable al trabajo con materiales sólidos, y que ha sido aplicada anteriormente en el estudio de diversos materiales de construcción. Los resultados obtenidos muestran cómo la citada técnica permite además de evaluar cualitativamente y cuantitativamente los colores de forma sencilla y objetiva, el disponer de las ventajas que conlleva actualmente el análisis instrumental: registro digital del color, tratamiento informatizado de datos y aumento de precisión y exactitud en las comparaciones cromáticas.

  4. Spectrophotometry of peculiar B and A stars. II. Eleven mercury-manganese stars

    International Nuclear Information System (INIS)

    Adelman, S.J.; Pyper, D.M.

    1979-01-01

    Spectrophotometry of eleven HgMn stars is presented for the optical region. As found in Paper I, the HgMn stars have systematically larger Δiota* and Δa values than the normal main sequence stars due to differences with respect to the mean continuum particularly of the lambda4464 values and the lambda5200 region, respectively. The HgMn stars exhibit a continuous range in the behavior of both the lambda4200 and lambda5200 regions between those stars that have index values larger than the appropriate criterion of presence and present definite evidence for the features to those stars with only a slight possibility of such features. The strengths of the lambda4200 and lambda5200 features appear not to be correlated. In the HgMn stars, both features may be due to differential line blocking. In the energy distribution of all eleven stars, the Balmer jump regions best fit the predictions of slightly hotter solar composition, log g=4.0, fully line blanketed model atmospheres than do the corresponding Paschen continua

  5. Quality control of test iodine in urine by spectrophotometry UV-Vis

    Science.gov (United States)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  6. A NEW CONCEPT FOR SPECTROPHOTOMETRY OF EXOPLANETS WITH SPACE-BORNE TELESCOPES

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Taro; Itoh, Satoshi; Shibai, Hiroshi; Sumi, Takahiro [Department of Earth and Space Science, Graduate School of Science, Osaka University, 1-1, Machikaneyamacho, Toyonaka, Osaka 560-0043 (Japan); Yamamuro, Tomoyasu [Optocraft, 3-16-8-101, Higashi Hashimoto, Midori-ku, Sagamihara, Kanagawa 252-0144 (Japan)

    2016-06-01

    We propose a new concept for the spectral characterization of transiting exoplanets with future space-based telescopes. This concept, called densified pupil spectroscopy, allows us to perform high, stable spectrophotometry against telescope pointing jitter and deformation of the primary mirror. This densified pupil spectrometer comprises the following three roles: division of a pupil into a number of sub-pupils, densification of each sub-pupil, and acquisition of the spectrum of each sub-pupil with a conventional spectrometer. Focusing on the fact that the divided and densified sub-pupil can be treated as a point source, we discovered that a simplified spectrometer allows us to acquire the spectra of the densified sub-pupils on the detector plane−an optical conjugate with the primary mirror−by putting the divided and densified sub-pupils on the entrance slit of the spectrometer. The acquired multiple spectra are not principally moved on the detector against low-order aberrations such as the telescope pointing jitter and any deformation of the primary mirror. The reliability of the observation result is also increased by statistically treating them. Our numerical calculations show that because this method suppresses the instrumental systematic errors down to 10 ppm under telescopes with modest pointing accuracy, next generation space telescopes with more than 2.5 m diameter potentially provide opportunities to characterize temperate super-Earths around nearby late-type stars through the transmission spectroscopy and secondary eclipse.

  7. Antioxidant study of quercetin and their metal complex and determination of stability constant by spectrophotometry method.

    Science.gov (United States)

    Ravichandran, R; Rajendran, M; Devapiriam, D

    2014-03-01

    Quercetin found chelate cadmium ions, scavenge free radicals produced by cadmium. Hence new complex, quercetin with cadmium was synthesised, and the synthesised complex structures were determined by UV-vis spectrophotometry, infrared spectroscopy, thermogravimetry and differential thermal analysis techniques (UV-vis, IR, TGA and DTA). The equilibrium stability constants of quercetin-cadmium complex were determined by Job's method. The determined stability constant value of quercetin-cadminum complex at pH 4.4 is 2.27×10(6) and at pH 7.4 is 7.80×10(6). It was found that the quercetin and cadmium ion form 1:1 complex in both pH 4.4 and pH 7.4. The structure of the compounds was elucidated on the basis of obtained results. Furthermore, the antioxidant activity of the free quercetin and quercetin-cadmium complexes were determined by DPPH and ABTS assays. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Comments on a Method to Measure Sucralose Using UV Photodegradation Followed by UV Spectrophotometry.

    Science.gov (United States)

    Fang, Te; Andrews, Susan A; Hofmann, Ron

    2017-05-01

    A simple and quick method to measure sucralose in aqueous solution at concentrations in the order of 0.1-1.2 g·L-1 proposed by Idris et al. uses UV irradiation prior to UV spectrophotometry. The photolysis of sucralose forms a photoactive compound characterized by maximum absorbance at approximately 270 nm. The conditions required for sucralose photolysis, however, had not been completely reported. In this work, the procedure described by Idris et al. was replicated using a low-pressure UV lamp to irradiate sucralose samples with a wider range of initial concentrations (0.04-10 g·L-1) with known fluences. It was determined that care must be taken to ensure that the same fluence is applied for both calibration and measurement steps because the absorbance of the sucralose photolysis product is a function of the applied fluence. The way the samples are irradiated also has an impact on the results in that the method exhibits a greater linear range if an apparatus is used that maximizes the fluence rate (e.g., by placing samples closer to the UV source or using a higher-intensity lamp).

  9. [Mutual Effect on Determination of Gibberellins and Glyphosate in Groundwater by Spectrophotometry].

    Science.gov (United States)

    Zhang, Li; Chen, Liang; Liu, Fei

    2015-04-01

    In the present study, a spectrophotometry method for the simultaneous determination of gibberellins (GA3) and glyphosate in groundwater was established and optimized. In addition, the mutual effect on simultaneous determination of GA3 and glyphosate was studied. Based on the experiment, good linearity (R2 > 0.99) was obtained for GA3 in the range of 0-20 and 0-100 µg and for glyphosate in the range of 0-8 and 5-15 µg. The method's detection limit (MDL) of GA3 and glyphosate was 0.48 and 0.82 µg, respectively; and the recovery rates of 15 to 150 µg GA3 and 3 to 10 µg glyphosate in all samples at a spiked level were 71.3% ± 1.9% and 98.4% ± 8.1%, respectively. No obvious influence of glyphosate (0-100 mg · L(-1)) on the recovery rates of GA3 was observed, but the presence of glyphosate could cause slight determination precision decrease of GA3. Meanwhile, adding 2 mg · L(-1) GA3 can increase the recovery rate of glyphosate.

  10. Simultaneous determination of sulphaquinoxaline and amprolium in veterinary mixture by HPLC and first derivative ultraviolet spectrophotometry

    International Nuclear Information System (INIS)

    El-Sattar, Osama Abd

    2002-01-01

    Two simple and reliable methods are described for the determination of sulphaquinoxaline (SQX) and amprolium (AMP) combined in veterinary powder. The first method depends on high performance liquid chromatography on a reversed phase column (Bondapak-C18) using mobile phase consisting of acetonitrile-methanol-water-phosphoric acid (30: 5: 55: 0.7, by volumes) at a flow rate of 1 ml min with UV detection at 254 nm. The detection limits were 0.2 ug ml and 0.35 ug ml and linearity ranges were 2-20 ug ml and 4-40ug ml for SQX and AMP, respectively. The second one deals with the first derivative (D) spectrophotometry with zero-crossing measurement at 253 nm and 226 nm for SQX and AMP respectively. The detection limits were 0.3 ug ml and linearity ranges were 1-18 ug ml and 4-32 ug-ml for SQX and AMP respectively. The proposed procedures were successfully applied to the determination of these drugs in laboratory prepared mixtures with mean percentage recovery ranged from 98.50 to 99.75 and in commercial preparation ranged from 103.85 to 104.85. (author)

  11. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method.

    Science.gov (United States)

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-10

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME)) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100μL of chloroform, 1.3mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0mgmL(-1) of MR in initial solution with R(2)=0.995 (n=5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015mgmL(-1), respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n=5). Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Analysis of trace metals in sodium by flameless atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Mahalingam, T.R.; Geetha, R.; Thiruvengadasamy, A.; Mathews, C.K.

    1981-01-01

    The estimation of trace metallic impurities in sodium is normally carried out by distilling off the sodium in vacuuum and analysing the residue by atomic absorption spectrophotometry (AAS). This paper describes the direct determination of the following impurities (viz.) Fe, Co, Ni, Cr, Mn, Ca, and Cu in sodium without going through the distillation step. Here sodium is simply dissolved and the solution is subjected to analysis by AAS using flameless atomisation in a graphite furnace. The method of standard additions is employed. Preliminary experiments were carried out to study the matrix effect of sodium on the atomic absorption of cobalt. It has been found that if pyrolysis is done at 1250 0 C for 20 seconds prior to atomisation, the bulk of the sodium nitrate matrix could be successfully removed. The use of the optimum pyrolysis temperatures for the various elements listed above and the matrix interference on the absorbances of these analytes are discussed in this paper. The precision and accuracy of our analytical procedure is also presented. (orig.)

  13. Environmental samples analysis by Atomic Absorption Spectrophotometry and Inductively Coupled Plasma-Optical Emission Spectroscopy

    International Nuclear Information System (INIS)

    Popescu, I.V.; Iordan, M.; Stihi, C.; Bancuta, A.; Busuioc, G.; Dima, G.; Ciupina, V.; Belc, M.; Vlaicu, Gh.; Marian, R.

    2002-01-01

    Biological samples are interesting from many aspects of environmental monitoring. By analyzing tree leaves conclusions can be drown regarding the metal loading in the growth medium. So that, starting from assumption that the pollution factors from environmental medium can modify the normal concentration of elements, we decided to control the presence of toxic elements and the deviation from normal state of elements in leaves of different trees from areas situated at different distances of pollution source. The aim of this work is to determine the elemental composition of tree leaves using Atomic Absorption Spectrophotometry (AAS) method and Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) method. Using AAS spectrophotometer SHIMADZU we identified and determined the concentration of: Cd, Co, Cu, Zn, Mn, Cr, Fe, Se, Pb with an instrumental error less than 1% for most of the elements analyzed. The same samples were analyzed by ICP-OES spectrometer, BAIRD ICP2070-Sequential Plasma spectrometer. We identified and determined in leaves of different trees the concentration of Mg, Ca, and Sr with a precision less than 6%. (authors)

  14. Determination of myoglobin based on its enzymatic activity by stopped-flow spectrophotometry

    Science.gov (United States)

    Zheng, Qi; Liu, Zhihong; Cai, Ruxiu

    2005-04-01

    A new method has been developed for the determination of myoglobin (Mb) based on its enzymatic activity for the oxidation of o-phenylenediamine (OPDA) with hydrogen peroxide. Stopped-flow spectrophotometry was used to study the kinetic behavior of the oxidation reaction. The catalytic activity of Mb was compared to other three kinds of catalyst. The time dependent absorbance of the reaction product, 2,3-diamimophenazine (DAPN), at a wavelength of 426 nm was recorded. The initial reaction rate obtained at 40 °C was found to be proportional to the concentration of Mb in the range of 1.0 × 10 -6 to 4.0 × 10 -9 mol L -1. The detection limit of Mb was found to be 9.93 × 10 -10 mol L -1. The relative standard deviations were within 5% for the determination of different concentrations of Mb. Excess of bovine serum albumin (BSA), Ca(II), Mg(II), Cu(II), glucose, caffeine, lactose and uric acid did not interfere.

  15. Quantitative analysis of trivalent uranium and lanthanides in a molten chloride by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Toshiyuki Fujii; Akihiro Uehara; Hajimu Yamana

    2013-01-01

    As an analytical application for pyrochemical reprocessing using molten salts, quantitative analysis of uranium and lanthanides by UV/Vis/NIR absorption spectrophotometry was performed. Electronic absorption spectra of LiCl-KCl eutectic at 773 K including trivalent uranium and eight rare earth elements (Y, La, Ce, Pr, Nd, Sm, Eu, and Gd as fission product elements) were measured in the wavenumber region of 4,500-33,000 cm -1 . The composition of the solutes was simulated for a reductive extraction condition in a pyroreprocessing process for spent nuclear fuels, that is, about 2 wt% U and 0.1-2 wt% rare earth elements. Since U(III) possesses strong absorption bands due to f-d transitions, an optical quartz cell with short light path length of 1 mm was adopted in the analysis. The quantitative analysis of trivalent U, Nd, Pr, and Sm was possible with their f-f transition intensities in the NIR region. The analytical results agree with the prepared concentrations within 2σ experimental uncertainties. (author)

  16. Atomic absorption spectrophotometry for the determination of metallic impurities in coal

    International Nuclear Information System (INIS)

    Silva, M.J.S.F. da.

    1983-06-01

    The Brazilian Energetic Alternative Program expects the reduction of our dependence on foreign energy sources, through replacing fuel oil by mineral coal. Its gasification by means of nuclear energy must be also considered. However, the intensive burning of coal leads to serious environmental problems. During its combustion the release, to atmosphere, of toxic elements such as As, Hg, Pb, Sb, Se, Cd, Zn and others is of great concern. Increase in atmospheric pollution will take place by burning increased amounts of coal. In addition, some of those elements are concentrated in fly ashes. The determination of impurities in coal is also important for the Figueiras Project in the Nuclebras Mineral Prospection Program. Hence, it is important to have reliable analytical methods which can monitor inorganic constituents at various stages of coal production and utilization. The atomic absorption spectrophotometry is a suitable analytical technique to determine pollutants in coal because it is sensitive, simple, economic and cover a large range of concentrations. The need of a previous treatment of the sample is overcome by using an acid attack (HNO 3 + HClO 4 + HF) which has proved to be rapid and efficient. (Author) [pt

  17. The analysis, by atomic-absorption spectrophotometry, of matte-leach residues

    International Nuclear Information System (INIS)

    Mallett, R.C.; Ring, E.J.; Middleton, H.R.; Dubois, M.

    1973-01-01

    Alternative methods for the analysis of matte-leach residues by atomic-absorption spectrophotometry were investigated. For the determination of the platinum-group metals, gold, and certain of the base metals, a fusion with sodium peroxide, followed by the separation of gold by reverse-phase chromatography and of the platinum-group metals by ion-exchange, is proposed. The noble metals are then determined in a solution that is free of most base metals including the sodium present as a result of the fusion. Copper, nickel, iron, calcium, magnesium, and aluminium can be determined after they have been removed from the ion-exchange column. Arsenic, selenium, tellurium, bismuth, tin, silver, lead, manganese, zinc, and cobalt can be determined in a separate sample after dissolution by a sealed-tube method. This is also an alternative method for the determination of copper, nickel, and iron. Chromium is determined separately after fusion with sodium peroxide, and silver can also be determined in this way. The laboratory method for these procedures is given as an appendix [af

  18. Determination of Oxytetracycline from Salmon Muscle and Skin by Derivative Spectrophotometry.

    Science.gov (United States)

    Toral, M Inés; Sabay, Tamara; Orellana, Sandra L; Richter, Pablo

    2015-01-01

    A method was developed for the identification and quantification of oxytetracycline residues present in salmon muscle and skin using UV-Vis derivative spectrophotometry. With this method, it was possible to reduce the number of steps in the procedure typically required for instrumental analysis of a sample. The spectral variables, order of the derivative, scale factor, smoothing factor, and analytical wavelength were optimized using standard solutions of oxytetracycline dissolved in 900 mg/L oxalic acid in methanol. The matrix effect was significant; therefore, quantification for oxytetracycline residues was carried out using drug-free salmon muscle and skin samples fortified with oxytetracycline. The LOD and LOQ were found to be 271 and 903 μg/kg, respectively. The precision and accuracy of the method were validated using drug-free salmon muscle and skin tissues fortified at three different concentrations (8, 16, and 32 mg/kg) on 3 different days. The recoveries at all fortified concentrations were between 90 and 105%, and RSDs in all cases were less than 6.5%. This method can be used to screen out compliant samples and thereby reduce the number of suspect positive samples that will require further confirmatory analysis.

  19. A new method for rapid determination of carbohydrate and total carbon concentrations using UV spectrophotometry.

    Science.gov (United States)

    Albalasmeh, Ammar A; Berhe, Asmeret Asefaw; Ghezzehei, Teamrat A

    2013-09-12

    A new UV spectrophotometry based method for determining the concentration and carbon content of carbohydrate solution was developed. This method depends on the inherent UV absorption potential of hydrolysis byproducts of carbohydrates formed by reaction with concentrated sulfuric acid (furfural derivatives). The proposed method is a major improvement over the widely used Phenol-Sulfuric Acid method developed by DuBois, Gilles, Hamilton, Rebers, and Smith (1956). In the old method, furfural is allowed to develop color by reaction with phenol and its concentration is detected by visible light absorption. Here we present a method that eliminates the coloration step and avoids the health and environmental hazards associated with phenol use. In addition, avoidance of this step was shown to improve measurement accuracy while significantly reducing waiting time prior to light absorption reading. The carbohydrates for which concentrations and carbon content can be reliably estimated with this new rapid Sulfuric Acid-UV technique include: monosaccharides, disaccharides and polysaccharides with very high molecular weight. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. The determination, by atomic-absorption spectrophotometry, of impurities in manganese dioxide

    International Nuclear Information System (INIS)

    Balaes, G.E.E.; Robert, R.V.D.

    1981-01-01

    This report describes various methods for the determination of impurities in electrolytic manganese dioxide by atomic-absorption spectrophotometry (AAS). The sample is dissolved in a mixture of acids, any residue being ignited and retreated with acid. Several AAS methods were applied so that the analysis required to meet the specifications could be attained. These involved conventional flame AAS, AAS with electrothermal atomization (ETA), hydride generation coupled with AAS, and cold-vapour AAS. Of the elements examined, copper, iron, zinc, and lead can be determined direct with confidence with or without corrections based on recoveries obtained from spiked solutions. Nickel can be determined direct by use of the method of standard additions, and copper, nickel, and lead by ETA with the method of standard additions. Arsenic and antimony are determined by hydride generation coupled with AAS, and mercury by cold-vapour AAS. The precision of analysis (relative standard deviation) is generally less than 0,050. Values were obtained for aluminium, molybdenum, magnesium, sodium, copper, chromium, and cadmium, but the accuracy of these determinations has not been fully established

  1. Headspace single-drop microextraction coupled to microvolume UV-vis spectrophotometry for iodine determination

    International Nuclear Information System (INIS)

    Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2009-01-01

    Headspace single-drop microextraction has been combined with microvolume UV-vis spectrophotometry for iodine determination. Matrix separation and preconcentration of iodide following in situ volatile iodine generation and extraction into a microdrop of N,N'-dimethylformamide is performed. An exhaustive characterization of the microextraction system and the experimental variables affecting iodine generation from iodide was carried out. The procedure employed consisted of exposing 2.5 μL of N,N'-dimethylformamide to the headspace of a 10 mL acidic (H 2 SO 4 2 mol L -1 ) aqueous solution containing 1.7 mol L -1 Na 2 SO 4 for 7 min. Addition of 1 mL of H 2 O 2 1 mol L -1 for in situ iodine generation was performed. The limit of detection was determined as 0.69 μg L -1 . The repeatability, expressed as relative standard deviation, was 4.7% (n = 6). The calibration working range was from 5 to 200 μg L -1 (r 2 = 0.9991). The large preconcentration factor obtained, ca. 623 in only 7 min, compensate for the 10-fold loss in sensitivity caused by the decreased optical path, which results in improved detection limits as compared to spectrophotometric measurements carried out with conventional sample cells. The method was successfully applied to the determination of iodine in water, pharmaceutical and food samples

  2. Determination of calcium and magnesium in hydroethanolic extracts of propolis by atomic absorption flame spectrophotometry

    Directory of Open Access Journals (Sweden)

    E. Q. SANTANA

    2009-01-01

    Full Text Available

    Propolis is a natural product collected by honeybees and has a large range of pharmacological activity, including antimicrobial, antitumoral, antioxidant and anti-inflammatory. Its use as a popular medicine is increasing all over the world, creating a need for quality control of the commercial products. In this study the levels of calcium and magnesium in commercial hydroalcoholic propolis extracts from varios states of Brazil were determined by atomic absorption flame spectrophotometry and different values were obtained for northern and southern states. This study can be extended to the analysis of metals that are harmful to health. The results showed that the calibration curves were linear over a wide concentration range (0.5-4.0 µg.mL-1 for calcium and 0.05-0.4 µg.mL-1 for magnesium with good correlation coefficients (0.999 and 0.988, respectively. Good analytical recovery (94% was obtained. The proposed method showed adequate precision and relative standard deviation lower than 2 %. The method is accurate and precise as well as having advantages such as simplicity and speed. Keywords: hydroalcoholic propolis extract; mineralization; analysis; calcium; magnesium.

  3. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method

    Science.gov (United States)

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-01

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100 μL of chloroform, 1.3 mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0 mg mL-1 of MR in initial solution with R2 = 0.995 (n = 5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015 mg mL-1, respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n = 5).

  4. Review of recent applications of flow injection spectrophotometry to pharmaceutical analysis

    International Nuclear Information System (INIS)

    Tzanavaras, Paraskevas D.; Themelis, Demetrius G.

    2007-01-01

    Pharmaceutical analysis is one of the most important fields in analytical chemistry. The discovery of new drugs and the on-going update of international regulations for the safety and efficacy of pharmaceutical formulations demand the continuous development of new analytical methods. Inevitably, automation plays an important role, especially when a lot of samples have to be analyzed in the minimum of time. The present study reviews the applications of flow injection (FI) spectrophotometry to the determination of active pharmaceutical ingredients (APIs) in their respective formulations. However, the topic covered in this study is important not only to pharmaceutical analytical scientists. The principles, figures of merit and 'chemistry' of the presented methods can be of interest to bio-analytical and clinical chemists as well for the analysis of biological samples, to environmental analysts that study the up-to-date demand of the determination of the fate of pharmaceuticals in the environment and even to toxicologists and forensic scientists. This review covers scientific contributions published later than 2000. A variety of FI procedures based on homogeneous (direct UV measurements, colour-forming reactions, metal-drug interactions) and heterogeneous (optical sensors and solid-phase reactors) systems are discussed. A third section covers on-line sample pretreatment (solid-phase extraction, liquid-liquid extraction, on-line digestion, etc.)

  5. Evaluation of Biologically Active Compounds from Calendula officinalis Flowers using Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Butnariu Monica

    2012-04-01

    Full Text Available Abstract Background This study aimed to quantify the active biological compounds in C. officinalis flowers. Based on the active principles and biological properties of marigolds flowers reported in the literature, we sought to obtain and characterize the molecular composition of extracts prepared using different solvents. The antioxidant capacities of extracts were assessed by using spectrophotometry to measure both absorbance of the colorimetric free radical scavenger 2,2-diphenyl-1-picrylhydrazyl (DPPH as well as the total antioxidant potential, using the ferric reducing power (FRAP assay. Results Spectrophotometric assays in the ultraviolet-visible (UV-VIS region enabled identification and characterization of the full range of phenolic and flavonoids acids, and high-performance liquid chromatography (HPLC was used to identify and quantify phenolic compounds (depending on the method of extraction. Methanol ensured more efficient extraction of flavonoids than the other solvents tested. Antioxidant activity in methanolic extracts was correlated with the polyphenol content. Conclusions The UV-VIS spectra of assimilator pigments (e.g. chlorophylls, polyphenols and flavonoids extracted from the C. officinalis flowers consisted in quantitative evaluation of compounds which absorb to wavelengths broader than 360 nm.

  6. Challenging Narcissus, or Reflecting on Reflecting.

    Science.gov (United States)

    Achilles, C. M.

    The concept of reflective practice and teaching people to be reflective practitioners is examined. The document begins with a look at professional knowledge according to three prominent professionals in the educational administration field: Schon, Schein, and Achilles. "Reflective" strategies that could be incorporated into courses and…

  7. Signal Words

    Science.gov (United States)

    SIGNAL WORDS TOPIC FACT SHEET NPIC fact sheets are designed to answer questions that are commonly asked by the ... making decisions about pesticide use. What are Signal Words? Signal words are found on pesticide product labels, ...

  8. UV SPECTROPHOTOMETRY APPLICATION FOR QUANTITATIVE DETERMINATION OF VINPOCETINE IN DRUG FORMULATIONS

    Directory of Open Access Journals (Sweden)

    J. V. Monaykina

    2014-12-01

    Full Text Available Introduction. In this paper simple, rapid and sensitive assay methods for quantitative determination of vinpocetine in two new drug formulations (suppositories and nasal cream are proposed. Analysis has been performed directly by using zero-order UV spectrophotometry. It is known from the special literature that the chromatographic techniques used for vinpocetine assay require expensive equipment and are rather time consuming. Therefore UV spectrophotometry is preferable due to its accuracy and simplicity. The object of this study was to develop new, simple, rapid, precise and accurate UV spectrophotometric procedure for the quantitative determination of vinpocetine in suppositories and nasal cream and evaluation of some validation characteristics of the methods. Materials and methods. The objects of the study were the new drug formulations of vinpocetine, namely 0,01 suppositories and 0,5% nasal cream developed by the scientists of The Chair of Technology of Drugs of Zaporizhzhia State Medical University. Distilled water and 0.05M HCl were used as the solvents, working standard sample of vinpocetine was used as a reference standard. Analytical equipment: spectrophotometer Specord 200, electronic balance ABT-120-5DM, measuring glassware of class A. Assay procedure: An accurately weighed sample of cream (1,200 – 2,000 g or one suppository was dissolved in 0.05M HCl and filtered into a 50,00 ml volumetric flask. Then the solution was brought to the mark with the same solvent and stirred. 3,00 ml or 4,00 ml of the resulting solutions (for suppositories or cream respectively were transferred into a 25,00 ml volumetric flask and brought to the mark with distilled water. Absorbance was measured at a wavelength of 272 nm on the blank of distilled water. The parallel measurement with 1,00 ml of 0,064% vinpocetine standard solution was carried out. The content of active substance was calculated according to standard formulas. Results. The suggested

  9. APPLICATION OF UV-SPECTROPHOTOMETRY FOR THE QUANTITATIVE DETERMINATION OF CAPTOPRIL IN DRUG

    Directory of Open Access Journals (Sweden)

    Yu. V. Monaykina

    2015-04-01

    Full Text Available Introduction. In this paper the simple, rapid and sensitive assay method for the quantitative determination of captopril in two new pharmaceutical formulations (suppositories and nasal gel is proposed. Analysis was performed directly by using zero-order UV spectrophotometry. It is known from the special literature that the chromatographic techniques used for captopril assay require the expensive equipment and are rather time consuming. Therefore UV spectrophotometry is preferable due to its accuracy, sensitivity and simplicity. The aim of this study was to develop and validate a new, simple, rapid, precise and accurate UV spectrophotometric method for the quantitative determination of captopril in suppositories and nasal gel. Materials and methods. The objects of the study were the new drug formulations of captopril, namely 0,05 suppositories and 2,5% nasal gel developed by the scientists of The Chair of Technology of Drugs ofZaporozhye State Medical University. Distilled water was used as the solvent, working standard sample of captopril was used as a reference standard. Analytical equipment: spectrophotometer Specord 200, electronic balance ABT-120-5DM, measuring glassware of class A. Assay procedure: An accurately weighed sample of gel (0,4000 –0,8000 g or one suppository was dissolved in distilled water and filtered into a volumetric flask (50,00 ml for gel and 250,0 ml for suppository . Then the solution was brought to the mark with the same solvent and stirred. 1,00 ml of the resulting solution was transferred into a 25,00 ml volumetric flask and brought to the mark with distilled water. Absorbance was measured at a wavelength of 203 nm on the blank of a solvent. The parallel measurement with 1,00 ml of 0,03% captopril standard solution was carried out. The content of active substance was calculated according to standard formulas. Results. The suggested procedure was successfully applied for the analysis of two new pharmaceutical

  10. Simultaneous determination of selenium and tellurium in native sulfur by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Arikawa, Yoshiko; Hirai, Shoji; Ozawa, Takejiro.

    1979-01-01

    A method for the determination of selenium and tellurium in native sulfur has been investigated by means of atomic absorption spectrophotometry. Native sulfur collected from around fumarole or volcanic crater is ground down into powder, a portion of which weighing 1 g is subjected to analysis. A 2.6% (w/v) sodium hydroxide solution is added by 10 ml to the sample in a teflon beaker, and the mixture is then heated on a hot plate. Sulfur is decomposed and dissolved in the form of disulfide and thiosulfate. A 30% hydrogenperoxide solution is added by 10 ml to oxidize them to sulfate. At the same time selenium and tellurium contained in the sulfur sample are also thought to be oxidized to Se(VI) and Te(VI) states. The solution is neutralized with hydrochloric acid and diluted with distilled water to 100 ml. The sample solution thus prepared is sprayed into the air-acetylene flame of the atomic absorption spectrophotometer. The absorbance is measured at 195.9 nm for selenium and 214.2 nm for tellurium. Calibration curve is prepared by measuring the absorbances of the solutions prepared as follows. One gram portions of pure sulfur (99.9999%) are decomposed as for the samples. After neutralization, standard solutions containing each same amount of selenium and tellurium (0 -- 1000 μg) are added to the sulfur solution and then diluted with water to 100 ml. The standard deviations were estimated to be 50.4 ppm for selenium at 756 ppm and 16.6 ppm for tellurium at 587 ppm. For the check of the reliability of the method, results were compared with those obtained by neutron activation analysis. Results obtained by both methods showed good agreement. (author)

  11. Evaluating optimal superficial limb perfusion at different angles using non-invasive micro-lightguide spectrophotometry.

    Science.gov (United States)

    Darmanin, Geraldine; Jaggard, Matthew; Hettiaratchy, Shehan; Nanchahal, Jagdeep; Jain, Abhilash

    2013-06-01

    It is common practice to elevate the limbs postoperatively to reduce oedema and hence optimise perfusion and facilitate rehabilitation. However, elevation may be counterproductive as it reduces the mean perfusion pressure. There are no clear data on the optimal position of the limbs even in normal subjects. The optimal position of limbs was investigated in 25 healthy subjects using a non-invasive micro-lightguide spectrophotometry system "O2C", which indirectly measures skin and superficial tissue perfusion through blood flow, oxygen saturation and relative haemoglobin concentration. We found a reduction in skin and superficial tissue blood flow of 17% (p=0.0001) on arm elevation (180° shoulder flexion) as compared to heart level and an increase in skin and superficial tissue blood flow of 25% (p=0.02) on forearm elevation of 45°. Lower limb skin and superficial tissue blood flow decreased by 15% (p=0.004) on elevation to 47 cm and by 70% on dependency (p=0.0001) compared to heart level. However, on elevation of the lower limb there was also a 28% reduction in superficial venous pooling (p=0.0001) compared to heart level. In the normal limb, the position for optimal superficial perfusion of the upper limb is with the arm placed at heart level and forearm at 45°. In the lower limb the optimal position for superficial perfusion would be at heart level. However, some degree of elevation may be useful if there is an element of venous congestion. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Noninvasive Measurement of Hemoglobin Using Spectrophotometry: Is it Useful for the Critically Ill Child?

    Science.gov (United States)

    Akyildiz, Basak

    2018-01-01

    This study compared the accuracy of noninvasively measuring hemoglobin using spectrophotometry (SpHb) with a pulse CO-oximeter and laboratory hemoglobin (Hb) measurements. A total of 345 critically ill children were included prospectively. Age, sex, and factors influencing the reliabilityof SpHb such as SpO2, heart rate, perfusion index (PI), and vasoactive inotropic score were recorded. SpHb measurements were recorded during the blood draw and compared with the Hb measurement. Thirteen patients (low PI in 9 patients and no available Hb in 4 patients) were excluded and 332 children were eligible for final analysis. The mean Hb was 8.71±1.49 g/dL (range, 5.9 to 12 g/dL) and the mean SpHb level was 9.55±1.53 g/dL (range, 6 to 14.2 g/dL). The SpHb bias was 0.84±0.86,with the limits of agreement ranging from -2.5 to 0.9 g/dL. The difference between Hb and SpHb was >1.5 g/dL for only 47 patients. Of these, 24 patients had laboratory Hb levels <7 g/dL. There was a weak positive correlation between differences and PI (r=0.349; P= 0.032). The pulse CO-oximeter is a promising tool for measuring SpHb and monitoring critically ill children. However, PI may affect these results. Additional studies investigating the reliability of the trend of continuous SpHb values compared with simultaneously measured laboratory Hb values in the same patient are warranted.

  13. Lead Quantification in Urine Samples of Athletes by Coupling DLLME with UV-Vis Spectrophotometry.

    Science.gov (United States)

    Faraji, Hakim; Helalizadeh, Masoumeh

    2017-04-01

    Urine lead level is one of the most employed measures of lead exposure and risk. The urine samples used in this study were obtained from ten healthy male cyclists. Dispersive liquid-liquid microextraction combined with ultraviolet and visible spectrophotometry was utilized for preconcentration, extraction, and determination of lead in urine samples. Optimization of the independent variables was carried out based on chemometric methods in three steps. According to the screening and optimization study, 133 μL of CCl 4 (extracting solvent), 1.34 mL ethanol (dispersing solvent), pH 2.0, 0.00 % of salt, and 0.1 % O,O-diethyl dithiophosphoric (chelating agent) were used as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R 2 was 0.9991, and linearity range was 0.01-100 μg L -1 . Precision was evaluated in terms of repeatability and intermediate precision, with relative standard deviations being <9.1 and <15.3 %, respectively. The accuracy was estimated using urine samples of cyclists as real samples and it was confirmed. The relative error of ≤5 % was considered significant in the method specificity study. The lead concentration mean for the cyclists was 3.79 μg L -1 in urine samples. As a result, the proposed method is a robust technique to quantify lead concentrations higher than 11.6 ng L -1 in urine samples.

  14. Estimation of nitrite in source-separated nitrified urine with UV spectrophotometry.

    Science.gov (United States)

    Mašić, Alma; Santos, Ana T L; Etter, Bastian; Udert, Kai M; Villez, Kris

    2015-11-15

    Monitoring of nitrite is essential for an immediate response and prevention of irreversible failure of decentralized biological urine nitrification reactors. Although a few sensors are available for nitrite measurement, none of them are suitable for applications in which both nitrite and nitrate are present in very high concentrations. Such is the case in collected source-separated urine, stabilized by nitrification for long-term storage. Ultraviolet (UV) spectrophotometry in combination with chemometrics is a promising option for monitoring of nitrite. In this study, an immersible in situ UV sensor is investigated for the first time so to establish a relationship between UV absorbance spectra and nitrite concentrations in nitrified urine. The study focuses on the effects of suspended particles and saturation on the absorbance spectra and the chemometric model performance. Detailed analysis indicates that suspended particles in nitrified urine have a negligible effect on nitrite estimation, concluding that sample filtration is not necessary as pretreatment. In contrast, saturation due to very high concentrations affects the model performance severely, suggesting dilution as an essential sample preparation step. However, this can also be mitigated by simple removal of the saturated, lower end of the UV absorbance spectra, and extraction of information from the secondary, weaker nitrite absorbance peak. This approach allows for estimation of nitrite with a simple chemometric model and without sample dilution. These results are promising for a practical application of the UV sensor as an in situ nitrite measurement in a urine nitrification reactor given the exceptional quality of the nitrite estimates in comparison to previous studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Determination of tin in biological reference materials by atomic absorption spectrophotometry and neutron activation analysis

    International Nuclear Information System (INIS)

    Chiba, M.; Iyengar, V.; Gills, T.

    1991-01-01

    Because of a lack of reliable analytical techniques for the determination of tin in biological materials, there have been no reference materials certified for this element. However, the authors' experience has shown that it is feasible to use both atomic absorption and nuclear activation techniques at least for selected matrices. Therefore, an investigation was undertaken to determine tin in several biological materials such as non-fat milk powder (NBS-SRM-1549), citrus leaves (NBS-SRM-1572), total diet (NIST-SRM-1548), mixed diet (NBS-RM-8431), and USDIET-I by atomic absorption spectrophotometry (AAS) and neutron activation analysis (NAA). AAS-ashed samples were extracted with MIBK and assayed using a Perkin Elmer model 5000 apparatus. NAA was carried out by irradiating the samples at the NIST reactor in the RT-4 facility and counting with the help of a Ge(Li) detector connected to a multichannel analyzer. The concentration of tin measured by both AAS and NAA agree well for USDIET-I, total diet, citrus leaves and non-fat milk powder (the concentration ranges for tin in these matrices were from 0.0025 to 3.8 micro g/g). However, in the case of mixed diet (RM-8431), the mean values found were 47 ± 5.6 (n = 19) by AAS and 55.5 ± 2.5 (n = 6) by INAA. Since RM-8431 is not certified it is difficult to draw conclusions. For apple and peach leaves, a distillation step was required. The results were apple leaves 0.085 ± 0.015 (n = 10) by AAS and < 0.2 (n = 3) by RNAA; for peach leaves 0.077 ± 0.02 (n = 9) by AAS and < 0.1 (n = 3) by RNAA. All concentrations are expressed in micro g/g dry weight

  16. Comparison of Ho and Y complexation data obtained by electromigration methods, potentiometry and spectrophotometry

    International Nuclear Information System (INIS)

    Vinsova, H.; Koudelkova, M.; Ernestova, M.; Jedinakova-Krizova, V.

    2003-01-01

    Many of holmium and yttrium complex compounds of both organic and inorganic origin have been studied recently from the point of view of their radiopharmaceutical behavior. Complexes with Ho-166 and Y-90 can be either directly used as pharmaceutical preparations or they can be applied in a conjugate form with selected monoclonal antibody. Appropriate bifunctional chelation agents are necessary in the latter case for indirect binding of monoclonal antibody and selected radionuclide. Our present study has been focused on the characterization of radionuclide (metal) - ligand interaction using various analytical methods. Electromigration methods (capillary electrophoresis, capillary isotachophoresis), potentiometric titration and spectrophotometry have been tested from the point of view of their potential to determine conditional stability constants of holmium and yttrium complexes. A principle of an isotachophoretic determination of stability constants is based on the linear relation between logarithms of stability constant and a reduction of a zone of complex. For the calculation of thermodynamic constants using potentiometry it was necessary at first to determine the protonation constants of acid. Those were calculated using the computer program LETAGROP Etitr from data obtained by potentiometric acid-base titration. Consequently, the titration curves of holmium and yttrium with studied ligands and protonation constants of corresponding acid were applied for the calculation of metal-ligand stability constants. Spectrophotometric determination of stability constants of selected systems was based on the titration of holmium and yttrium nitrate solutions by Arsenazo III following by the titration of metal-Arsenazo III complex by selected ligand. Data obtained have been evaluated using the computation program OPIUM. Results obtained by all analytical methods tested in this study have been compared. It was found that direct potentiometric titration technique could not be

  17. Comparative study between optical densitometry and spectrophotometry for evaluation of PMMA dosimeters

    International Nuclear Information System (INIS)

    Louback, Luana Trevenzoli; Meira-Belo, Luiz C.

    2011-01-01

    The use of dosimetric systems based on color changes in PMMA is standardized by ISO/ASTM 51276:2002(E). In a general way, the evaluation of doses in these materials is done correlating the optical absorbance of the material and the absorbed dose. Usually, the absorbance is measured using a spectrophotometer at a wavelength suitably chosen. In the present work, it was performed a comparative study between the techniques of spectrophotometry and optical densitometry in dyed PMMA dosimeters type Harwell RED 4034 and PMMA samples commercially available in Brazil. The main results of this study were the determination of the radiochromic response for different samples of PMMA and the determination of the calibration conditions using a 60 Co beam. The studied materials are suitable for use as routine dosimeters, covering the range of the 500Gy to 100kGy. A direct comparison between the red dyed PMMA and the Harwell RED 4034 Perspex showed that the stabilization time and the fading of the radiochromic information in red dyed PMMA samples is higher than in RED 4034. However, both effects occur on period of weeks, which does not preclude its routine use. Furthermore, the increase in absorbance due to exposure to radiation, determined by the difference between specific absorbance of the irradiated sample and a non-irradiated one, is significantly higher in PMMA with red dyed that the RED 4034. In fact, the amplitude of absorbance peak of a sample irradiated with red dyed PMMA 2kGy and read at 602nm has the same order of magnitude from a peak of RED 4034 irradiated with 10 kGy and read at 640nm. A direct consequence of this fact is the real possibility of using simpler equipment (optical densitometer in this case) to measure the optical absorbance and evaluates the absorbed dose. (author)

  18. Liquid-phase microextraction and fibre-optics-based cuvetteless CCD-array micro-spectrophotometry for trace analysis

    International Nuclear Information System (INIS)

    Sharma, Nisha; Pillai, Aradhana K.K.V.; Pathak, Neeraj; Jain, Archana; Verma, Krishna K.

    2009-01-01

    Liquid-phase microextraction (LPME) has been investigated for trace analysis in the present work in conjunction with fibre-optic-based micro-spectrophotometry which accommodates sample volume of 1 μL placed between the two ends of optical fibres. Methods have been evolved for the determination of (i) 1-100 μM and 0.5-20 μM of thiols by single drop microextraction (SDME) and LPME in 25 μL of the organic solvent, respectively, involving their reaction with the Ellman reagent and ion pair microextraction of thiolate ion formed; (ii) 70 μg to 7 mg L -1 of chlorine/chlorine dioxide by headspace in-drop reaction with alternative reagents, viz., mixed phenylhydrazine-4-sulphonic acid and N-(1-naphthyl)ethylenediamine dihydrochloride, o-dianisidine, o-tolidine, and N,N-diethyl-p-phenylenediamine; (iii) 0.2-4 mg L -1 of ammonia by reaction with 2,4-dinitro-1-fluorobenzene to give 2,4-dinitroaniline which was diazotized and coupled with 1-naphthylamine, the resulting dye was subjected to preconcentration by solid-phase extraction and LPME; and (iv) 25-750 μg L -1 of iodide/total iodine by oxidation of iodide by 2-iodosobenzoate, microextraction of iodine in organic solvent, and re-extraction into aqueous starch-iodide reagent drop held in the organic phase. LPME using 25-30 μL of organic solvent was found to produce more sensitive results than SDME. The cuvetteless spectrophotometry as used in combination with sample handling techniques produced limits of detection of analytes which were better than obtained by previously reported spectrophotometry.

  19. HPLC determination of flavonoid glycosides in Mongolian Dianthus versicolor Fisch. (Caryophyllaceae) compared with quantification by UV spectrophotometry.

    Science.gov (United States)

    Obmann, Astrid; Purevsuren, Sodnomtseren; Zehl, Martin; Kletter, Christa; Reznicek, Gottfried; Narantuya, Samdan; Glasl, Sabine

    2012-01-01

    Dianthus versicolor is used in traditional Mongolian medicine against liver impairment. Fractions enriched in flavone-di- and triglycosides were shown to enhance bile secretion. Therefore, reliable and accurate analytical methods are needed for the determination of these flavonoids in the crude drug and extracts thereof. To provide a validated HPLC-DAD (diode array detector) method especially developed for the separation of polar flavonoids and to compare the data obtained with those evaluated by UV spectrophotometry. Separations were carried out on an Aquasil® C₁₈-column (4.6 mm × 250.0 mm, 5 µm) with a linear gradient of acetonitrile and water (adjusted to pH 2.8 with trifluoroacetic acid) as mobile phase. Rutoside was employed as internal standard with linear behavior in a concentration range of 0.007-3.5 mg/mL. Accuracy was determined by spiking the crude drug with saponarin resulting in recoveries between 92% and 102%. The method allows the quantification of highly polar flavonoid glycosides and the determination of their total content. For saponarin a linear response was evaluated within the range 0.007-3.5 mg/mL (R²  > 0.9999). It was proven that threefold sonication represents a time-saving, effective and cheap method for the extraction of the polar flavonoid glycosides. The contents determined by HPLC were shown to be in agreement with those obtained employing UV spectrophotometry. The study has indicated that the newly developed HPLC method represents a powerful technique for the quality control of D. versicolor. Ultraviolet spectrophotometry may be used alternatively provided that the less polar flavonoids are removed by purification. Copyright © 2011 John Wiley & Sons, Ltd.

  20. SECTIONING METHOD APPLICATION AT ELLIPSOMETRY OF INHOMOGENEOUS REFLECTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. N. Gorlyak

    2014-05-01

    Full Text Available The paper deals with investigation of application peculiarities of ellipsometry methods and UF spectrophotometry at mechanical and chemical processing of optical engineering surface elements made of quartz glass. Ellipsometer LEF–3M–1, spectrophotometer SF–26 and interferometer MII–4 are used as experiment tools; they obtain widely known technical characteristics. Polarization characteristics of reflected light beam were measured by ellipsometry method; spectrophotometry method was used for measuring radiation transmission factor in UF spectrum area; by interference method surface layer thickness at quartz glass etching was measured. A method for HF–sectioning of inhomogeneous surface layer of polished quartz glass is developed based on ellipsometry equation for reflection system «inhomogeneous layer – inhomogeneous padding». The method makes it possible to carry out the measuring and analysis of optical characteristics for inhomogeneous layers system on inhomogeneous padding and to reconstruct optical profile of surface layers at quartz glass chemical processing. For definition of refractive index change along the layer depth, approximation of experimental values for polarization characteristics of homogeneous layers system is used. Inhomogeneous surface layer of polished quartz glass consists of an area (with thickness up to 20 nm and layer refractive index less than refractive index for quartz glass and an area (with thickness up to 0,1 μm and layer refractive index larger than refractive index for quartz glass. Ellipsometry and photometry methods are used for definition of technological conditions and optical characteristics of inhomogeneous layers at quartz glass chemical processing for optical elements with minimum radiation losses in UF spectrum area.

  1. A thin alanine-polyethylene film dosimetry system with diffuse reflection spectrophotometric evaluation

    International Nuclear Information System (INIS)

    Zagorski, Z.P.; Rafalski, A.

    1995-01-01

    Characteristics of a new alanine dosimeter in the shape of a thin film, with the measurement of optical absorption of the CH 3 CHCOO - radical is described. That type of dosimeter, ALA/DRS (for diffuse reflection spectrophotometry) is compared, to an alanine dosimeter with EPR evaluation (ALA/EPR for short). In many respects the simple ALA/DRS version, as the alanine-polyethylene composite is superior. The paper shows the importance of the new experimental approach to free radical research in solid state radiation chemistry. (author). 7 refs., 3 figs

  2. Spectroscopic studies of Wolf-Rayet stars. V - Optical spectrophotometry of the emission lines in Small Magellanic Cloud stars

    International Nuclear Information System (INIS)

    Conti, P.S.; Garmany, C.D.; Massey, P.

    1989-01-01

    Spectrophotometry of the strongest emission-line features for the eight known WR stars in the SMC is presented. Seven are relatively early WN types; and one is a WO. These are compared to stars of similar spectral types in the Galaxy and the LMC. The hydrogen-burning CNO cycle equilibrium nitrogen abundance with respect to helium appears to be similar to that in WN stars of the Galaxy and LMC even though the SMC objects presumably began their lives with appreciably smaller CNO content. 28 refs

  3. Spectrophotometry of the Hα region in the spectrum of HR 1099 during the February 1978 radio flare

    International Nuclear Information System (INIS)

    Fraquelli, D.A.

    1978-01-01

    Spectrophotometry of the Hα emission line in the spectrum of HR 1099 (=HD 22468=V711 Tauri) was obtained during the radio flare of February 1978. The profiles observed during the flare have higher peak intensities and larger equivalent widths than profiles obtained outside of the flare at approximately the same orbital phases. Both the general shapes of the profiles and the equivalent widths appear to correlate with the radio flux. A preflare profile exhibits a flare-type profile, suggesting that radio outbursts in RS CVn systems may be preceded by Hα enhancement

  4. Determination of silver in soils, sediments, and rocks by organic-chelate extraction and atomic absorption spectrophotometry

    Science.gov (United States)

    Chao, T.T.; Ball, J.W.; Nakagawa, H.M.

    1971-01-01

    A useful method for the determination of silver in soil, sediment, and rock samples in geochemical exploration has been developed. The sample is digested with concentrated nitric acid, and the silver extracted with triisooctyl thiophosphate (TOTP) in methyl isobutyl ketone (MIBK) after dilution of the acid digest to approximately 6 M. The extraction of silver into the organic extractant is quantitative and not affected by the nitric acid concentration from 4 M to 8 M, or by different volumes of TOTP-MIBK. The extracted silver is stable and remains in the organic phase up to several days. The silver concentration is determined by atomic absorption spectrophotometry. ?? 1971.

  5. Spectrophotometry of Pluto-Charon mutual events - Individual spectra of Pluto and Charon

    Science.gov (United States)

    Sawyer, S. R.; Barker, E. S.; Cochran, A. L.; Cochran, W. D.

    1987-01-01

    Time-resolved spectra of the March 3 and April 4, 1987 mutual events of Pluto and Charon, obtained with spectral coverage from 5500 to 10,000 A with 25-A spectral resolution, are discussed. Charon has a featureless reflectance spectrum, with no evidence of methane absorption. Charon's reflectance appears neutral in color and corresponds to a geometric albedo of about 0.37 at 6000 A. The Pluto reflectance spectrum displays methane absorption bands at 7300, 7900, 8400, 8600, and 8900 A and is red in color, with a geometric albedo of about 0.56 at 6000 A.

  6. The cuticle modulates ultraviolet reflectance of avian eggshells

    Directory of Open Access Journals (Sweden)

    Daphne C. Fecheyr-Lippens

    2015-07-01

    Full Text Available Avian eggshells are variedly coloured, yet only two pigments, biliverdin and protoporphyrin IX, are known to contribute to the dramatic diversity of their colours. By contrast, the contributions of structural or other chemical components of the eggshell are poorly understood. For example, unpigmented eggshells, which appear white to the human eye, vary in their ultraviolet (UV reflectance, which may be detectable by birds. We investigated the proximate mechanisms for the variation in UV-reflectance of unpigmented bird eggshells using spectrophotometry, electron microscopy, chemical analyses, and experimental manipulations. We specifically tested how UV-reflectance is affected by the eggshell cuticle, the outermost layer of most avian eggshells. The chemical dissolution of the outer eggshell layers, including the cuticle, increased UV-reflectance for only eggshells that contained a cuticle. Our findings demonstrate that the outer eggshell layers, including the cuticle, absorb UV-light, probably because they contain higher levels of organic components and other chemicals, such as calcium phosphates, compared to the predominantly calcite-based eggshell matrix. These data highlight the need to examine factors other than the known pigments in studies of avian eggshell colour.

  7. Sensitive determination of total particulate phosphorus and particulate inorganic phosphorus in seawater using liquid waveguide spectrophotometry.

    Science.gov (United States)

    Ehama, Makoto; Hashihama, Fuminori; Kinouchi, Shinko; Kanda, Jota; Saito, Hiroaki

    2016-06-01

    Determining the total particulate phosphorus (TPP) and particulate inorganic phosphorus (PIP) in oligotrophic oceanic water generally requires the filtration of a large amount of water sample. This paper describes methods that require small filtration volumes for determining the TPP and PIP concentrations. The methods were devised by validating or improving conventional sample processing and by applying highly sensitive liquid waveguide spectrophotometry to the measurements of oxidized or acid-extracted phosphate from TPP and PIP, respectively. The oxidation of TPP was performed by a chemical wet oxidation method using 3% potassium persulfate. The acid extraction of PIP was initially carried out based on the conventional extraction methodology, which requires 1M HCl, followed by the procedure for decreasing acidity. While the conventional procedure for acid removal requires a ten-fold dilution of the 1M HCl extract with purified water, the improved procedure proposed in this study uses 8M NaOH solution for neutralizing 1M HCl extract in order to reduce the dilution effect. An experiment for comparing the absorbances of the phosphate standard dissolved in 0.1M HCl and of that dissolved in a neutralized solution [1M HCl: 8M NaOH=8:1 (v:v)] exhibited a higher absorbance in the neutralized solution. This indicated that the improved procedure completely removed the acid effect, which reduces the sensitivity of the phosphate measurement. Application to an ultraoligotrophic water sample showed that the TPP concentration in a 1075mL-filtered sample was 8.4nM with a coefficient of variation (CV) of 4.3% and the PIP concentration in a 2300mL-filtered sample was 1.3nM with a CV of 6.1%. Based on the detection limit (3nM) of the sensitive phosphate measurement and the ambient TPP and PIP concentrations of the ultraoligotrophic water, the minimum filtration volumes required for the detection of TPP and PIP were estimated to be 15 and 52mL, respectively. Copyright © 2016

  8. Detecting estrogenic activity in water samples withestrogen-sensitive yeast cells using spectrophotometry and fluorescencemicroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wozei, E.; Holman, H-Y.N.; Hermanowicz, S.W.; Borglin S.

    2006-03-15

    Environmental estrogens are environmental contaminants that can mimic the biological activities of the female hormone estrogen in the endocrine system, i.e. they act as endocrine disrupters. Several substances are reported to have estrogen-like activity or estrogenic activity. These include steroid hormones, synthetic estrogens (xenoestrogens), environmental pollutants and phytoestrogens (plant estrogens). Using the chromogenic substrate ortho-nitrophenyl-{beta}-D-galactopyranoside (ONPG) we show that an estrogen-sensitive yeast strain RMY/ER-ERE, with human estrogen receptor (hER{alpha}) gene and the lacZ gene which encodes the enzyme {beta}-galactosidase, is able to detect estrogenic activity in water samples over a wide range of spiked concentrations of the hormonal estrogen 17{beta}-estradiol (E2). Ortho-nitrophenol (ONP), the yellow product of this assay can be detected using spectrophotometry but requires cell lysis to release the enzyme and allow product formation. We improved this aspect in a fluorogenic assay by using fluorescein di-{beta}-D-galactopyranoside (FDG) as a substrate. The product was visualized using fluorescence microscopy without the need to kill, fix or lyse the cells. We show that in live yeast cells, the uptake of E2 and the subsequent production of {beta}-galactosidase enzyme occur quite rapidly, with maximum enzyme-catalyzed fluorescent product formation evident after about 30 minutes of exposure to E2. The fluorogenic assay was applied to a selection of estrogenic compounds and the Synchrotron-based Fourier transform infrared (SR-FTIR) spectra of the cells obtained to better understand the yeast whole cell response to the compounds. The fluorogenic assay is most sensitive to E2, but the SR-FTIR spectra suggest that the cells respond to all the estrogenic compounds tested even when no fluorescent response was detected. These findings are promising and may shorten the duration of environmental water screening and monitoring regimes using

  9. Atomic absorption spectrophotometry of europium using an enhancing effect of ammonium perchlorate

    International Nuclear Information System (INIS)

    Oguro, Hiroshi

    1976-01-01

    In the atomic absorption spectrophotometry of europium in air-acetylene flame, ammonium perchlorate (NH 4 ClO 4 ) increases the absorption of europium. In the case of 0.5 M NH 4 ClO 4 , the increase is by about 1.5 times. In this paper, a method for eliminating the interferences of many coexisting compounds using an enhancing effect and a method for determining Eu 2 O 3 in La 2 O 3 were investigated. The working conditions using Nippon Jarrell-Ash model AA-1 atomic absorption/flame emission spectrophotometer were as follows; wavelength 4594 A, lamp current 15 mA, burner height 10 mm, air flow-rate 6.51/min, acetylene flow-rate 1.81/min. Though the enhancing or depressing effects of HCl, HNO 3 , HBr and HClO 4 in concentrations below 0.1 M were eliminated by 0.5 M NH 4 ClO 4 , the remarkable depressing effects of H 2 SO 4 and H 3 PO 4 on europium could not be eliminated. The interferences of Na + , K + , Cs + and Al 3+ in the concentration of 200 ppm were not eliminated, but those of other cations including rare earth elements were completely eliminated. Lanthanum in the range of (2000--10000) ppm increased the absorption of europium by about 1.4 times. But the effect of lanthanum in the range of (0--9000) ppm was also eliminated by NH 4 ClO 4 . The calibration curve for europium in the presence of NH 4 ClO 4 was linear in the range of (0--400) ppm with a sensitivity larger by about 1.5 times than that for europium alone. The analytical procedure is as follows. A sample is dissolved in HCl and NH 4 ClO 4 is added. Europium in the sample solution is determined by atomic absorption method using air-acetylene flame. For practical samples, the values obtained were in fair agreement with those by the flame emission method using a nitrous oxide-acetylene flame. The coefficients of variation by the present method were (3.7--2.4)% (Eu 2 O 3 content (1--3)%). (auth.)

  10. Relative bioavailability studies on a locally manufactured aspirin tablets using UV spectrophotometry and HPLC

    International Nuclear Information System (INIS)

    Kwadzo, Ameko David

    2005-11-01

    Modern trends in drug analysis require use of less time consuming, efficient, cost effective, fast, reproducible, simple and convenient methods. Two analytical methods were employed for the determination, the UV spectrophotometry and the HPLC. Aspirin, which is rapidly deacetylated to salicylic acid after absorption into the plasma, is excreted in the urine. In determining the salicylic acid concentration in the urine, the absorbance was quantitated by a spectrometer at a wavelength of 540nm. Aspirin formed an amber coloured complex with ferric ions (Trinder’s reagent). The complex, which formed instantaneously at room temperature, was stable. The solution of the complex obeyed Beer’s law at 540nm, the wavelength of maximum absorption of radiation (λmax). Phenol—induced absorbance is quenched by acidifying the reaction mixture with phosphoric acid. An HPLC analytical method was used in determining the free salicylate excreted in the urine. The mobile phase employed is a validated method from the USP- XXII (1990) which consists of water, methanol and glacial acetic acid in the ratio 69: 28: 3 respectively. The chromatographic conditions involved a flow rate of 1.0ml/rnin, wavelength of maximum absorption of 236nrn, stationary phase Spherisorb S5 ODS 1 phase sep column with standard dimensions of 25.0 cm length and 4.6cm diameter and chart recorder speed of 5mm/min. The quality of the reference and the test tablets were assessed by a number of standard tests, which include uniformity of weight, friability, hardness and dissolution that fall within the BP 2000 specification. The observation from the study reveals that the relative bioavailability of aspirin (w.r.t. salicylic acid) were 103.39% and 94.93% for HPLC and UV respectively. The mean cumulative percentage of the drug excreted in both cases were ii .05% and 10.69% for test and reference respectively for HPLC and 76.45% and 80.53% for test and reference respectively for UV analysis. The cumulative amount

  11. Solid methane on Triton and Pluto - 3- to 4-micron spectrophotometry

    Science.gov (United States)

    Spencer, John R.; Buie, Marc W.; Bjoraker, Gordon L.

    1990-01-01

    Methane has been identified in the Pluto/Charon system on the basis of absorption features in the reflectance spectrum at 1.5 and 2.3 microns; attention is presently given to observations of a 3.25 micron-centered deep absorption feature in Triton and Pluto/Charon system reflectance spectra. This absorption may indicate the presence of solid methane, constituting either the dominant surface species or a mixture with a highly transparent substance, such as N2 frost.

  12. Fully-differential spectrophotometry determination of trace thorium in uranium-containing waste water separated by CL-TBP levextrel resin

    International Nuclear Information System (INIS)

    You Jiannan

    2000-01-01

    A method for separation by CL-TBP levextrel resin and determination of trace thorium in uranium-containing waste water by fully-differential spectrophotometry is developed. In 4 mol/L HNO 3 medium, in presence of tartaric acid, CL-TBP levextrel resin is used for adsorption of thorium and separating from other elements. The thorium on the resin is stripped by 4 mol/L HCl, with oxalic acid and urea as screening agent, thorium forms red complex with arsenazo III. The maximum absorption of the complex is at 668 nm, and the molar absorptivity is 1.27 x 10 5 L/(mol·cm) . The complex can be steady for 2.5 h. By regulating micro-current of differential spectrophotometry, the method can realize determination with high precision. Sensitivity of this method increase 10 times than usual spectrophotometry. The relative standard deviation is better than +- 5% and recovery of thorium is 99%-107%

  13. ATP signals

    DEFF Research Database (Denmark)

    Novak, Ivana

    2016-01-01

    The Department of Biology at the University of Copenhagen explains the function of ATP signalling in the pancreas......The Department of Biology at the University of Copenhagen explains the function of ATP signalling in the pancreas...

  14. Zero crossing and ratio spectra derivative spectrophotometry for the dissolution tests of amlodipine and perindopril in their fixed dose formulations

    Directory of Open Access Journals (Sweden)

    Maczka Paulina

    2014-06-01

    Full Text Available Dissolution tests of amlodipine and perindopril from their fixed dose formulations were performed in 900 mL of phosphate buffer of pH 5.5 at 37°C using the paddle apparatus. Then, two simple and rapid derivative spectrophotometric methods were used for the quantitative measurements of amlodipine and perindopril. The first method was zero crossing first derivative spectrophotometry in which measuring of amplitudes at 253 nm for amlodipine and 229 nm for perindopril were used. The second method was ratio derivative spectrophotometry in which spectra of amlodipine over the linearity range were divided by one selected standard spectrum of perindopril and then amplitudes at 242 nm were measured. Similarly, spectra of perindopril were divided by one selected standard spectrum of amlodipine and then amplitudes at 298 nm were measured. Both of the methods were validated to meet official requirements and were demonstrated to be selective, precise and accurate. Since there is no official monograph for these drugs in binary formulations, the dissolution tests and quantification procedure presented here can be used as a quality control test for amlodipine and perindopril in respective dosage forms.

  15. A simple and cost-effective method, as an appropriate alternative for visible spectrophotometry: development of a dopamine biosensor.

    Science.gov (United States)

    Abbaspour, Abdolkarim; Khajehzadeh, Abdolreza; Ghaffarinejad, Ali

    2009-08-01

    In this study, a new, simple, fast and inexpensive method as an alternative to visible spectrophotometry is developed. In this method the cells containing the sample solution were scanned with a scanner, then the color of each cell was analyzed with software written in visual basic (VB 6) media to red, green and blue values. The cells were built by creating holes in the Plexiglas sheet. The dimensions of identical cells were examined by Cr (III) solution with known concentrations. The validity of this new method was studied by determination of dopamine (DA) without using any other reagent. The parameters which affect the system were optimized. The comparison between the current and traditional UV-Vis spectrophotometry methods was studied and the results revealed similar trends in both methods. The developed method was successfully applied to the determination of dopamine in serum and urine without using any pretreatment. Finally comparing the results obtained in the developed method showed that microwave irradiation of the solution can decrease the experimental time, increase sensitivity and improve the limit of detection.

  16. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    Science.gov (United States)

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  17. Derivative spectrophotometry for the determination of faropenem in the presence of degradation products: an application for kinetic studies.

    Science.gov (United States)

    Cielecka-Piontek, Judyta

    2013-07-01

    A simple and selective derivative spectrophotometric method was developed for the quantitative determination of faropenem in pure form and in pharmaceutical dosage. The method is based on the zero-crossing effect of first-derivative spectrophotometry (λ = 324 nm), which eliminates the overlapping effect caused by the excipients present in the pharmaceutical preparation, as well as degradation products, formed during hydrolysis, oxidation, photolysis, and thermolysis. The method was linear in the concentration range 2.5-300 μg/mL (r = 0.9989) at λ = 341 nm; the limits of detection and quantitation were 0.16 and 0.46 μg/mL, respectively. The method had good precision (relative standard deviation from 0.68 to 2.13%). Recovery of faropenem ranged from 97.9 to 101.3%. The first-order rate constants of the degradation of faropenem in pure form and in pharmaceutical dosage were determined by using first-derivative spectrophotometry. A statistical comparison of the validation results and the observed rate constants for faropenem degradation with these obtained with the high-performance liquid chromatography method demonstrated that both were compatible.

  18. Intraoperative Vascular Neuromonitoring in Patients with Subarachnoid Hemorrhage: A Pilot Study Using Combined Laser-Doppler Spectrophotometry.

    Science.gov (United States)

    Schmitz, Emilija; Bischoff, Barbara; Wolf, Dennis; Schmitt, Hubert J; Eyupoglu, Ilker Y; Roessler, Karl; Buchfelder, Michael; Sommer, Björn

    2017-11-01

    Intraoperative monitoring of cerebral microcirculation in patients with subarachnoid hemorrhage (SAH) may predict the postoperative neurologic outcome. In this pilot study, we examined the value of a novel noninvasive real-time measurement technique for detecting changes in local microcirculation. We used the O2C (Oxygen to see) laser-Doppler spectrophotometry system in 14 patients with Hunt & Hess grade 2-5 SAH who underwent microsurgical cerebral aneurysm clipping. A subdural probe recorded capillary venous oxygenation (SO 2 ), relative hemoglobin concentration, blood cell velocity, and blood flow at a tissue depth of 7 mm. Data were recorded immediately before dural closure. We also recorded somatosensory evoked potentials (SEPs) with median and tibial nerve stimulation. Results were compared with neurologic performance, as measured on the modified Rankin Scale, at the day of discharge from the hospital and 12 months thereafter. Patient functional outcomes after discharge and 12 months were correlated with pathological decreased flow and increased SO 2 values. In 6 of 8 patients, microcirculatory monitoring parameters indicated ischemia during surgery, as shown by electrophysiological SEP changes and infarction detected on the postoperative computed tomography (CT) scan. Pathological SEP results correlated closely with infarct demarcation as seen on CT. Our results indicate the potential benefit of intraoperative combined laser-Doppler flowmetry and spectrophotometry for predicting postoperative clinical outcomes in this small patient sample. Larger-cohort testing is needed to verify our findings and show the possible merits of this novel method. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Temperature-reflection I

    DEFF Research Database (Denmark)

    McGady, David A.

    2017-01-01

    -temperature path integrals for quantum field theories (QFTs) should be T-reflection invariant. Because multi-particle partition functions are equal to Euclidean path integrals for QFTs, we expect them to be T-reflection invariant. Single-particle partition functions though are often not invariant under T......In this paper, we revisit the claim that many partition functions are invariant under reflecting temperatures to negative values (T-reflection). The goal of this paper is to demarcate which partition functions should be invariant under T-reflection, and why. Our main claim is that finite...... that T-reflection is unrelated to time-reversal. Finally, we study the interplay between T-reflection and perturbation theory in the anharmonic harmonic oscillator in quantum mechanics and in Yang-Mills in four-dimensions. This is the first in a series of papers on temperature-reflections....

  20. Radar reflection off extensive air showers

    CERN Document Server

    Stasielak, J; Bertaina, M; Blümer, J; Chiavassa, A; Engel, R; Haungs, A; Huege, T; Kampert, K -H; Klages, H; Kleifges, M; Krömer, O; Ludwig, M; Mathys, S; Neunteufel, P; Pekala, J; Rautenberg, J; Riegel, M; Roth, M; Salamida, F; Schieler, H; Šmída, R; Unger, M; Weber, M; Werner, F; Wilczyński, H; Wochele, J

    2012-01-01

    We investigate the possibility of detecting extensive air showers by the radar technique. Considering a bistatic radar system and different shower geometries, we simulate reflection of radio waves off the static plasma produced by the shower in the air. Using the Thomson cross-section for radio wave reflection, we obtain the time evolution of the signal received by the antennas. The frequency upshift of the radar echo and the power received are studied to verify the feasibility of the radar detection technique.

  1. Simulation Tool for GNSS Ocean Surface Reflections

    DEFF Research Database (Denmark)

    Høeg, Per; von Benzon, Hans-Henrik; Durgonics, Tibor

    2015-01-01

    GNSS coherent and incoherent reflected signals have the potential of deriving large scale parameters of ocean surfaces, as barotropic variability, eddy currents and fronts, Rossby waves, coastal upwelling, mean ocean surfaceheights, and patterns of the general ocean circulation. In the reflection...... zone the measurements may deriveparameters as sea surface roughness, winds, waves, heights and tilts from the spectral measurements. Previous measurements from the top of mountains and airplanes have shown such results leading.The coming satellite missions, CYGNSS, COSMIC-2, and GEROS...

  2. Near-infrared reflectance analysis by Gauss-Jordan linear algebra

    International Nuclear Information System (INIS)

    Honigs, D.E.; Freelin, J.M.; Hieftje, G.M.; Hirschfeld, T.B.

    1983-01-01

    Near-infrared reflectance analysis is an analytical technique that uses the near-infrared diffuse reflectance of a sample at several discrete wavelengths to predict the concentration of one or more of the chemical species in that sample. However, because near-infrared bands from solid samples are both abundant and broad, the reflectance at a given wavelength usually contains contributions from several sample components, requiring extensive calculations on overlapped bands. In the present study, these calculations have been performed using an approach similar to that employed in multi-component spectrophotometry, but with Gauss-Jordan linear algebra serving as the computational vehicle. Using this approach, correlations for percent protein in wheat flour and percent benzene in hydrocarbons have been obtained and are evaluated. The advantages of a linear-algebra approach over the common one employing stepwise regression are explored

  3. Liberating Moral Reflection

    Science.gov (United States)

    Horell, Harold D.

    2013-01-01

    The author argues that if we are to foster life-giving and liberating moral reflection, we must first liberate moral reflection from distortions; specifically, from the distorting effects of moral insensitivity, destructive moral relativism, and confusions resulting from a failure to understand the dynamics of moral reflection. The author proposes…

  4. Simple spectrophotometry method for the determination of sulfur dioxide in an alcohol-thionyl chloride reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jinjian, E-mail: jinjian.zheng@merck.com; Tan, Feng; Hartman, Robert

    2015-09-03

    Thionyl chloride is often used to convert alcohols into more reactive alkyl chloride, which can be easily converted to many compounds that are not possible from alcohols directly. One important reaction of alkyl chloride is nucleophilic substitution, which is typically conducted under basic conditions. Sulfur dioxide, the by-product from alcohol-thionyl chloride reactions, often reacts with alkyl chloride to form a sulfonyl acid impurity, resulting in yield loss. Therefore, the alkyl chloride is typically isolated to remove the by-products including sulfur dioxide. However, in our laboratory, the alkyl chloride formed from alcohol and thionyl chloride was found to be a potential mutagenic impurity, and isolation of this compound would require extensive safety measures. As a result, a flow-through process was developed, and the sulfur dioxide was purged using a combination of vacuum degassing and nitrogen gas sweeping. An analytical method that can quickly and accurately quantitate residual levels of sulfur dioxide in the reaction mixture is desired for in-process monitoring. We report here a simple ultraviolet (UV) spectrophotometry method for this measurement. This method takes advantage of the dramatic change in the UV absorbance of sulfur dioxide with respect to pH, which allows for accurate quantitation of sulfur dioxide in the presence of the strong UV-absorbing matrix. Each sample solution was prepared using 2 different diluents: 1) 50 mM ammonium acetate in methanol +1% v/v hydrochloric acid, pH 1.3, and 2) 50 mM ammonium acetate in methanol +1% glacial acetic acid, pH 4.0. The buffer solutions were carefully selected so that the UV absorbance of the sample matrix (excluding sulfur dioxide) at 276 nm remains constant. In the pH 1.3 buffer system, sulfur dioxide shows strong UV absorbance at 276 nm. Therefore, the UV absorbance of sample solution is the sum of sulfur dioxide and sample matrix. While in the pH 4.0 buffer system, sulfur dioxide has

  5. Signaling aggression.

    Science.gov (United States)

    van Staaden, Moira J; Searcy, William A; Hanlon, Roger T

    2011-01-01

    From psychological and sociological standpoints, aggression is regarded as intentional behavior aimed at inflicting pain and manifested by hostility and attacking behaviors. In contrast, biologists define aggression as behavior associated with attack or escalation toward attack, omitting any stipulation about intentions and goals. Certain animal signals are strongly associated with escalation toward attack and have the same function as physical attack in intimidating opponents and winning contests, and ethologists therefore consider them an integral part of aggressive behavior. Aggressive signals have been molded by evolution to make them ever more effective in mediating interactions between the contestants. Early theoretical analyses of aggressive signaling suggested that signals could never be honest about fighting ability or aggressive intentions because weak individuals would exaggerate such signals whenever they were effective in influencing the behavior of opponents. More recent game theory models, however, demonstrate that given the right costs and constraints, aggressive signals are both reliable about strength and intentions and effective in influencing contest outcomes. Here, we review the role of signaling in lieu of physical violence, considering threat displays from an ethological perspective as an adaptive outcome of evolutionary selection pressures. Fighting prowess is conveyed by performance signals whose production is constrained by physical ability and thus limited to just some individuals, whereas aggressive intent is encoded in strategic signals that all signalers are able to produce. We illustrate recent advances in the study of aggressive signaling with case studies of charismatic taxa that employ a range of sensory modalities, viz. visual and chemical signaling in cephalopod behavior, and indicators of aggressive intent in the territorial calls of songbirds. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. 40 CFR 156.64 - Signal word.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Signal word. 156.64 Section 156.64... REQUIREMENTS FOR PESTICIDES AND DEVICES Human Hazard and Precautionary Statements § 156.64 Signal word. (a... signal word, reflecting the highest Toxicity Category (Category I is the highest toxicity category) to...

  7. Media for Reflection

    DEFF Research Database (Denmark)

    Knudsen, Morten

    2016-01-01

    This article develops the concept media for reflection in the interest of conceptualizing the interpretative frames that enable and limit reflection in management and leadership education. The concept ‘media for reflection’ allows us to conceptualize the social and cultural mediation of reflection...... without reducing reflection to an effect of the social structures and cultural norms in which it is embedded. Based on the developed theoretical framework, this article analyses how a renaissance ‘mirror for princes’ and contemporary research-based management education mediate reflection. The content...... of the mediations is analysed as well as the societal and organizational background. Furthermore, the means by which the two media enable and limit reflection in different ways is compared. Finally, the article discusses possible implications of the analysis in terms of management and leadership education....

  8. THE DETERMINATION OF BUPROPION HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS BY ORIGINAL UV- AND SECOND DERIVATIVE UV SPECTROPHOTOMETRY, POTENTIOMETRIC AND CONDUCTOMETRIC METHODS

    Directory of Open Access Journals (Sweden)

    Duygu YENİCELİ

    2010-08-01

    Full Text Available Spectrophotometric, potentiometric and conductometric methods are developed for the determination of bupropion hydrochloride (BLIP in pharmaceutical tablets. For the first method, original UV-spectrophotometry, 252 nm was determined as the optimum wavelength and used for the determinations. For the other method, second derivative UV spectrophotometry, the absorbances were measured at 217.4 and 221.8 nm and the distance between these extremum values was determined according to peak to peak method. Two spectrophotometric methods were validated over the concentration range of 5.72 - 20.03 ug/mL. The limit of detection and limit of quantitation values of original UV-spectrophotometry were 0.75 ug/mL and 2.28 jug/mL. Also, these parameters were determined as 0.23 ug/mL and 0.68 ug/mL respectively, for the second derivative UV spectrophotometry. Developed methods were fully validated and the applicability of the methods for the determination of BUP in pharmaceuticals were demonstrated. Also, simple potentiometric and conductometric methods were developed and the applicability of these methods were demonstrated. The results of four analytical methods were compared with ANOVA test and no significant difference was found statistically. As a result, the developed methods could be proposed to the rutin content analysis to be simple, cheap, accurate, and precise

  9. Quantitative determination of praesodymium(III)-neodymium(III)-holmium(III)-erbium(III) four-component systems by matrix-fourth derivative spectrophotometry

    International Nuclear Information System (INIS)

    Wu Yang; Jinzhang Gao; Jingwan Kang; Guangbi Bai; Cunxiong Li

    1994-01-01

    A new approach is developed through a combination of matrix representation and higher derivative spectrophotometry and can be used to analyse seven four-component mixtures of lanthanide ions, simultaneously, with a recovery of between 92.0 and 107.1%. The method is rapid, sensitive and accurate and is suitable for a large number of samples. (Author)

  10. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    Science.gov (United States)

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Measurement of uranium concentration by molecular absorption spectrophotometry by means optical fibers; Medicion continua de concentracion de uranio por espectrofotometria de absorcion molecular mediante fibras opticas

    Energy Technology Data Exchange (ETDEWEB)

    Gauna, Alberto C.; Pascale, Ariel A. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro Atomico Ezeiza. Agencia Minipost

    1996-07-01

    An on-line method for measuring the concentration of uranium in uranyl nitrate-nitric acid aqueous solutions is described. The method is based on molecular absorption spectrophotometry with transmission of light by means of optical fibers. It is ideally suited for control and processes development applications. (author)

  12. Uranium determination by spectrophotometry, in chloride solutions, using titanium (III) as reducer; Determinacao de uranio por espectrofotometria, em solucoes cloridricas, utilizando titanio (III) como redutor

    Energy Technology Data Exchange (ETDEWEB)

    Bastos, E T.R.; Bastos, M B.R.

    1986-08-01

    A simple method for determining uranium in uranium (VI) solutions with the presence of uranium (IV), iron (II), and titanium (IV) in chloridic solution is described. The method comprises in uranium (VI) reduction with titanium (III), acidity adjustment and uranium (IV) spectrophotometry in hydrochloric acid 2 M. (C.G.C.).

  13. Principles of neutron reflection

    International Nuclear Information System (INIS)

    Felcher, G.P.

    1988-08-01

    Neutron reflection is perhaps the most developed branch of slow neutrons optics, which in itself is a direct consequence of the undulatory nature of the neutron. After reviewing the basic types of interactions (nuclear and magnetic) between neutrons and matter, the formalism is introduced to calculate the reflectivity from a sample composed of stacked flat layers and, inversely, to calculate the stacking from reflectivity measurements. Finally, a brief survey of the applications of neutron reflection is given, both in technology and in fundamental research. 32 refs., 6 figs

  14. Storage array reflection considerations

    International Nuclear Information System (INIS)

    Haire, M.J.; Jordan, W.C.; Taylor, R.G.

    1997-01-01

    The assumptions used for reflection conditions of single containers are fairly well established and consistently applied throughout the industry in nuclear criticality safety evaluations. Containers are usually considered to be either fully water-reflected (i.e. surrounded by 6 to 12 in. of water) for safety calculations or reflected by 1 in. of water for nominal (structural material and air) conditions. Tables and figures are usually available for performing comparative evaluations of containers under various loading conditions. Reflection considerations used for evaluating the safety of storage arrays of fissile material are not as well established

  15. Simultaneous determination of dysprosium, holmium and erbium in high purity rare earth oxides by second order derivative spectrophotometry

    International Nuclear Information System (INIS)

    Anbu, M.; Prasada Rao, T.; Iyer, C. S. P.; Damodaran, A. D.

    1996-01-01

    High purity individual rare earth oxides are increasingly used as major components in lasers (Y 2 O 3 ), phosphors (YVO 3 , Eu 2 O 3 ), magnetic bubble memory films (Gd 2 O 3 ) and refractive-index lenses and fibre optics (La 2 O 3 ). The determination of individual lanthanides in high purity rare earth oxides is a more important and difficult task. This paper reports the utilization of higher order derivative spectrophotometry for the simultaneous determination of dysprosium, holmium and erbium in high purity rare earth oxides. The developed procedure is simple, reliable and allows the determination of 0.001 to 0.2% of dysprosium, holmium and erbium in several rare earth. (author). 9 refs, 2 figs, 2 tabs

  16. Use of Dispersive Liquid-Liquid Microextraction and UV-Vis Spectrophotometry for the Determination of Cadmium in Water Samples

    Directory of Open Access Journals (Sweden)

    J. Pérez-Outeiral

    2014-01-01

    Full Text Available A simple and inexpensive method for cadmium determination in water using dispersive liquid-liquid microextraction and ultraviolet-visible spectrophotometry was developed. In order to obtain the best experimental conditions, experimental design was applied. Calibration was made in the range of 10–100 μg/L, obtaining good linearity (R2 = 0.9947. The obtained limit of detection based on calibration curve was 8.5 μg/L. Intra- and interday repeatability were checked at two levels, obtaining relative standard deviation values from 9.0 to 13.3%. The enrichment factor had a value of 73. Metal interferences were also checked and tolerable limits were evaluated. Finally, the method was applied to cadmium determination in real spiked water samples. Therefore, the method showed potential applicability for cadmium determination in highly contaminated liquid samples.

  17. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    Science.gov (United States)

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  18. Evaluation of clinoptilolite for removal of ammoniacal nitrogen produced in aquaculture by Neutron activation analysis and UV-VIS spectrophotometry

    International Nuclear Information System (INIS)

    Bibiano C, L.; Iturbe G, J.L.; Lopez M, B.E.; Martinez M, V.

    1997-01-01

    In fish culture system, ammonia is excreted in the water as a metabolic by-product. In this work, sorption properties of clinoptilolite were determined and it was applied in culture of the rainbow trout Oncorhynchus mykiss for the removal of the ammoniacal nitrogen. The original clinoptilolite was treated with 1N NaCl solution from 24 to 192 h, for exchange NH 4 ions produced in fish culture. The content of Na in the clinoptilolite was determined by neutron activation analysis. The ammonium ion content in the exchange was analysed by UV-VIS spectrophotometry. Maximum uptake of sodium was reached between 24 and 48 hours at neutral pH with granules of the clinoptilolite from 14 to 24 mesh size. The adsorption capacity was from 3.28 to 6.8 mg of ammonium per gram of clinoptilolite. (Author)

  19. UV spectrophotometry for monitoring the performance of a yeast-based deoxygenation process to treat ships' ballast water.

    Science.gov (United States)

    Veilleux, Éloïse; de Lafontaine, Yves; Thomas, Olivier

    2016-04-01

    This study assessed the usefulness of UV spectrophotometry for the monitoring of a yeast-based deoxygenation process proposed for ships' ballast water treatment to prevent the transfer of aquatic invasive species. Ten-day laboratory experiments using three treatment concentrations and different water types were conducted and resulted in complete oxygen depletion of treated waters. The treatment performance and quality of treated waters were determined by measuring the UV-visible absorbance spectra of water samples taken over time. Samples were also used for laboratory analysis of water quality properties. The UV absorbance spectra values were strongly correlated (r = 0.96) to yeast cell density in treated waters. The second-order derivative (D (2)) of the spectra varied greatly over time, and the spectrum profiles could be divided into two groups corresponding to the oxygenated and anoxic phases of the treatment. The D (2) value at 215 nm was strongly correlated (r = 0.94) to ammonia levels, which increased over time. The D (2) value at 225 nm was strongly correlated (r > 0.97) to DO concentration. Our results showed that UV spectrophotometry may provide a rapid assessment of the behavior and performance of the yeast bioreactor over time by quantifying (1) the density of yeast cells, (2) the time at which anoxic conditions were reached, and (3) a water quality index of the treated water related to the production of ammonia. We conclude that the rapidity of the technique confers a solid advantage over standard methods used for water quality analysis in laboratory and would permit the direct monitoring of the treatment performance on-board ships.

  20. Benefit of cerebrospinal fluid spectrophotometry in the assessment of CT scan negative suspected subarachnoid haemorrhage: a diagnostic accuracy study.

    Science.gov (United States)

    Hann, Angus; Chu, Kevin; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2015-01-01

    This study aimed to determine if performing cerebrospinal fluid spectrophotometry in addition to visual inspection detects more ruptured cerebral aneurysms than performing cerebrospinal fluid visual inspection alone in patients with a normal head CT scan but suspected of suffering an aneurysmal subarachnoid haemorrhage (SAH). We performed a single-centre retrospective study of patients presenting to the emergency department of a tertiary hospital who underwent both head CT scan and lumbar puncture to exclude SAH. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of an approach utilising both spectrophotometry and visual inspection (combined approach) was compared to visual inspection alone. A total of 409 patients (mean age 37.8 years, 56.2% female) were recruited and six (1.5%) had a cerebral aneurysm on angiography. The sensitivity of visual inspection was 50% (95% confidence interval [CI]: 12.4-82.6%), specificity was 99% (95% CI: 97.5-99.7%), PPV was 42.9% (95% CI: 10.4-81.3%) and NPV was 99.2% (95% CI: 97.8-99.8%). The combined approach had a sensitivity of 100% (95% CI: 54.1-100%), specificity of 79.7% (95% CI: 75.4-83.5%), PPV of 6.8% (95% CI: 2.6-14.3%) and a NPV of 100% (95% CI: 98.8-100%). The sensitivity of the combined approach was not significantly different to that of visual inspection alone (p=0.25). Visual inspection had a significantly higher specificity than the combined approach (p<0.01). The combined approach detected more cases of aneurysmal SAH than visual inspection alone, however the difference in sensitivity was not statistically significant. Visual xanthochromia should prompt angiography because of a superior specificity and PPV. Due to its reduced sensitivity, caution should be applied when using only visual inspection of the supernatant. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  1. Determination of Uranium In UO2 And U3O8 Powder Using UV-VIS Spectrophotometry

    International Nuclear Information System (INIS)

    Natalia Adventini; Diah Dwiana Lestiani; Muhayatun; Endah Damastuti

    2009-01-01

    Lab. TAR PTNBR BATAN - Bandung has been accredited by National Accreditation Committee on May 2 nd , 2006 as a test laboratory with number LP-311-ID, has to maintain its laboratory performance by participating in a proficiency test. In this activity, the determination of uranium in 2 samples of UO 2 with A1 and A2 codes and other 2 samples of U 3 O 8 with B1 and B2 codes using UV-Vis spectrophotometry was carried out. Colouring method was used by reacting thiocyanate ion with the uranyl ion in acidic solution to develop a stable yellow colour of uranyl thiocyanate complex solution and measured at wavelength of 380 nm. The result gave that concentration of uranium in A1, A2, B1 and B2 samples were 77.95; 75.29; 64.58 and 63.69% respectively. The Z-score value for A samples was - 1.99, meanwhile for B samples the Z score value of between laboratory was −1.29 with intra laboratory was -1,09. It meant that Z-score values for both samples were in good category. From this result, it showed that UV-Vis spectrophotometry is one of the several methods that can be used to determine uranium in UO 2 and U 3 O 8 powder. The Lab. TAR’s proficiency test for determination of uranium in UO 2 and U 3 O 8 gave a good result and it was hoped to support BATAN's program in the nuclear fuel field. (author)

  2. Validation of quantitative analysis method for triamcinolone in ternary complexes by UV-Vis spectrophotometry

    Directory of Open Access Journals (Sweden)

    GEORGE DARLOS A. AQUINO

    2011-06-01

    Full Text Available Triamcinolone (TRI, a drug widely used in the treatment of ocular inflammatory diseases, is practically insoluble in water, which limits its use in eye drops. Cyclodextrins (CDs have been used to increase the solubility or dissolution rate of drugs. The purpose of the present study was to validate a UV-Vis spectrophotometric method for quantitative analysis of TRI in inclusion complexes with beta-cyclodextrin (B-CD associated with triethanolamine (TEA (ternary complex. The proposed analytical method was validated with respect to the parameters established by the Brazilian regulatory National Agency of Sanitary Monitoring (ANVISA. The analytical measurements of absorbance were made at 242nm, at room temperature, in a 1-cm path-length cuvette. The precision and accuracy studies were performed at five concentration levels (4, 8, 12, 18 and 20μg.mL-1. The B-CD associated with TEA did not provoke any alteration in the photochemical behavior of TRI. The results for the measured analytical parameters showed the success of the method. The standard curve was linear (r2 > 0.999 in the concentration range from 2 to 24 μg.mL-1. The method achieved good precision levels in the inter-day (relative standard deviation-RSD <3.4% and reproducibility (RSD <3.8% tests. The accuracy was about 80% and the pH changes introduced in the robustness study did not reveal any relevant interference at any of the studied concentrations. The experimental results demonstrate a simple, rapid and affordable UV-Vis spectrophotometric method that could be applied to the quantitation of TRI in this ternary complex. Keywords: Validation. Triamcinolone. Beta-cyclodextrin. UV- Vis spectrophotometry. Ternary complexes. RESUMO Validação de método de análise quantitativa para a triancinolona a partir de complexo ternário por espectrofotometria de UV-Vis A triancinolona (TRI é um fármaco amplamente utilizado no tratamento de doenças inflamatórias do globo ocular e

  3. Signal detection

    International Nuclear Information System (INIS)

    Tholomier, M.

    1985-01-01

    In a scanning electron microscope, whatever is the measured signal, the same set is found: incident beam, sample, signal detection, signal amplification. The resulting signal is used to control the spot luminosity with the observer cathodoscope. This is synchronized with the beam scanning on the sample; on the cathodoscope, the image in secondary electrons, backscattered electrons,... of the sample surface is reconstituted. The best compromise must be found between a register time low enough to remove eventual variations (under the incident beam) of the nature of the observed phenomenon, and a good spatial resolution of the image and a signal-to-noise ratio high enough. The noise is one of the basic limitations of the scanning electron microscope performance. The whose measurement line must be optimized to reduce it [fr

  4. Rapid measurement of indocyanine green retention by pulse spectrophotometry: a validation study in 70 patients with Child-Pugh A cirrhosis before hepatectomy for hepatocellular carcinoma.

    Science.gov (United States)

    Cheung, Tan To; Chan, See Ching; Chok, Kenneth S H; Chan, Albert C Y; Yu, Wan Ching; Poon, Ronnie T P; Lo, Chung Mau; Fan, Sheung Tat

    2012-06-01

    The indocyanine green (ICG) retention test is the most popular liver function test for selecting patients for major hepatectomy. Traditionally, it is done using spectrophotometry with serial blood sampling. The newly-developed pulse spectrophotometry is a faster alternative, but its accuracy on Child-Pugh A cirrhotic patients undergoing hepatectomy for hepatocellular carcinoma has not been well documented. This study aimed to assess the accuracy of the LiMON(®), one of the pulse spectrophotometry systems, in measuring preoperative ICG retention in these patients and to devise an easy formula for conversion of the results so that they can be compared with classical literature records where ICG retention was measured by the traditional method. We measured the liver function of 70 Child-Pugh A cirrhotic patients before hepatectomy for hepatocellular carcinoma from September 2008 to January 2009. ICG retention at 15 minutes measured by traditional spectrophotometry (ICGR15) was compared with ICG retention at 15 minutes measured by the LiMON (ICGR15(L)). The median ICGR15 was 14.7% (5.6%-32%) and the median ICGR15(L) was 10.4% (1.2%-28%). The mean difference between them was -4.3606. There was a strong correlation between ICGR15 and ICGR15(L) (correlation coefficient, 0.844; 95% confidence interval, 0.762-0.899). The following formula was devised: ICGR15=1.16XICGR15(L)+2.73. The LiMON provides a fast and repeatable way to measure ICG retention at 15 minutes, but with constant underestimation of the real value. Therefore, when comparing results obtained by traditional spectrophotometry and the LiMON, adjustment of results from the latter is necessary, and this can be done with a simple mathematical calculation using the above formula.

  5. Sub-parts-per-quadrillion-level graphite furnace atomic absorption spectrophotometry based on laser wave mixing.

    Science.gov (United States)

    Mickadeit, Fritz K; Berniolles, Sandrine; Kemp, Helen R; Tong, William G

    2004-03-15

    Nonlinear laser wave mixing in a common graphite furnace atomizer is presented as a zeptomole-level, sub-Doppler, high-resolution atomic absorption spectrophotometric method. A nonplanar three-dimensional wave-mixing optical setup is used to generate the signal beam in its own space. Signal collection is efficient and convenient using a template-based optical alignment. The graphite furnace atomizer offers advantages including fast and convenient introduction of solid, liquid, or gas analytes, clean atomization environment, and minimum background noise. Taking advantage of the unique features of the wave-mixing optical method and those of the graphite furnace atomizer, one can obtain both excellent spectral resolution and detection sensitivity. A preliminary concentration detection limit of 0.07 parts-per-quadrillion and a preliminary mass detection limit of 0.7 ag or 8 zmol are determined for rubidium using a compact laser diode as the excitation source.

  6. Dissenting in Reflective Conversations

    DEFF Research Database (Denmark)

    Bjørn, Pernille; Boulus, Nina

    2011-01-01

    Reflective monitoring of research practices is essential. However, we often lack formal training in the practices of doing action research, and descriptions of actual inquiry practice are seldom included in publications. Our aim is to provide a glimpse of self-reflective practices based on our...

  7. Self-Reflection

    DEFF Research Database (Denmark)

    Fausing, Bent

    2016-01-01

    will take a look at the establishing of the modern self and possibilities of self-reflection, too. My examples will be from the so-called dark-selfies and from a new selfie form, which merge the present with the previous progressing into the future. I will discuss the media reflections as loos and/or gain...

  8. Reflection: A Socratic approach.

    Science.gov (United States)

    Van Seggelen-Damen, Inge C M; Van Hezewijk, René; Helsdingen, Anne S; Wopereis, Iwan G J H

    2017-12-01

    Reflection is a fuzzy concept. In this article we reveal the paradoxes involved in studying the nature of reflection. Whereas some scholars emphasize its discursive nature, we go further and underline its resemblance to the self-biased dialogue Socrates had with the slave in Plato's Meno . The individual and internal nature of the reflection process creates difficulty for studying it validly and reliably. We focus on methodological issues and use Hans Linschoten's view of coupled systems to identify, analyze, and interpret empirical research on reflection. We argue that researchers and research participants can take on roles in several possible system couplings. Depending on who controls the manipulation of the stimulus, who controls the measuring instrument, who interprets the measurement and the response, different types of research questions can be answered. We conclude that reflection may be validly studied by combining different couplings of experimenter, manipulation, stimulus, participant, measurement, and response.

  9. Storage array reflection considerations

    International Nuclear Information System (INIS)

    Haire, M.J.; Jordan, W.C.; Taylor, R.G.

    1997-01-01

    The assumptions used for reflection conditions of single containers are fairly well established and consistently applied throughout the industry in nuclear criticality safety evaluations. Containers are usually considered to be either fully water reflected (i.e., surrounded by 6 to 12 in. of water) for safety calculations or reflected by 1 in. of water for nominal (structural material and air) conditions. Tables and figures are usually available for performing comparative evaluations of containers under various loading conditions. Reflection considerations used for evaluating the safety of storage arrays of fissile material are not as well established. When evaluating arrays, it has become more common for analysts to use calculations to demonstrate the safety of the array configuration. In performing these calculations, the analyst has considerable freedom concerning the assumptions made for modeling the reflection of the array. Considerations are given for the physical layout of the array with little or no discussion (or demonstration) of what conditions are bounded by the assumed reflection conditions. For example, an array may be generically evaluated by placing it in a corner of a room in which the opposing walls are far away. Typically, it is believed that complete flooding of the room is incredible, so the array is evaluated for various levels of water mist interspersed among array containers. This paper discusses some assumptions that are made regarding storage array reflection

  10. The Reflective Foundation

    DEFF Research Database (Denmark)

    Lunde Jørgensen, Ida

    Private foundations and cultural philanthropy by élites is viewed with increasing skepticism in recent years, begging the question of the extent to which foundations reflect on their role vis a vis wider societal norms. Through the prism of the New Carlsberg Foundation, financed by the brewery...... Carlsberg A/S, the paper seeks to elucidate the way in which one culturally significant foundation from Denmark has reflected on - and legitimated - its work and investments at critical moments in the past decades. The paper indicates a foundation with a high degree of reflection on the wider societal...

  11. Reproducibility and signal response linearity of Alanine gel dosimeter

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo Silva; Campos, Leticia Lucente

    2008-01-01

    Gel Dosimetry has been studied mainly for medical applications, because it presents signal response in the dose range used in radiotherapy treatments and it can be applied for three dimensional dosimetry. Alanine gel dosimeter is a new gel material developed at IPEN that presents significant improvement on previous alanine systems developed by Costa (1994). The DL-Alanine (C 3 H 7 NO 2 ) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. These ferric ions concentration can be measured by spectrophotometry technique. This work aims to study the reproducibility of the alanine gel solutions and the signal response as a function of gamma radiation dose, considering that these two properties are very important for characterizing and standardizing any dosimeter. (author)

  12. Seasonal soybean crop reflectance

    Science.gov (United States)

    Lemaster, E. W. (Principal Investigator); Chance, J. E.

    1983-01-01

    Data are presented from field measurements of 1980 including 5 acquisitions of handheld radiometer reflectance measurements, 7 complete sets of parameters for implementing the Suits mode, and other biophysical parameters to characterize the soybean canopy. LANDSAT calculations on the simulated Brazilian soybean reflectance are included along with data collected during the summer and fall on 1981 on soybean single leaf optical parameters for three irrigation treatments. Tests of the Suits vegetative canopy reflectance model for the full hemisphere of observer directions as well as the nadir direction show moderate agreement for the visible channels of the MSS and poor agreement in the near infrared channel. Temporal changes in the spectral characteristics of the single leaves were seen to occur as a function of maturity which demonstrates that the absorptance of a soybean single leaf is more a function of thetransmittancee characteristics than the seasonally consistent single leaf reflectance.

  13. Standard test method for color and color difference of whitewares by abriged spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method describes the instrumental measurement of the reflection properties and color of ceramic glazes and other whitewares by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most specimens having an exterior flat surface large enough to cover the spectrophotometer sample port. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. The first experience in estimation of basal cell carcinoma cryoresistence using noninvasive spectrophotometry

    Science.gov (United States)

    Andrukhina, V. V.; Litvinova, K. S.; Nikitin, A. A.; Spiridonova, N. Z.; Rogatkin, D. A.

    2010-02-01

    The urgency of BCC study affecting maxillofacial area and neck is not only caused by high prevalence of this disease, but also insufficient efficiency of existing treatment methods which lead to full or partial recovery only in 60-80% of cases. We analyzed the results of 198 BCC cases cryosurgical treatment. 33 (16,6%) patients showed continued tumor growth. It has been hypothesized that the behavior and character of microcirculation changes during patient's testing have to correlate with damaging rate of tumors that will allow to develop indications for surgical treatment with local destruction - cryosurgery or cryolaser treatment. We have tested the new group of 33 patients with primary and recurrence types of basal cell carcinoma (BCC) by means of Laser Doppler Flowmetry, Tissues Reflectance Oximetry, Laser Fluorescence Diagnostics before operation. It was shown that the microcirculatory data indicates the presence of cryoresistance.

  15. Wave reflections from breakwaters

    OpenAIRE

    Dickson, William S.

    1994-01-01

    A new method is presented for estimating the reflection of a random, multi-directional sea from a coastal structure. The technique is applicable to an array of wave gauges of arbitrary geometry deployed seaward of the reflector. An expansion for small oblique wave incidence angles is used to derive an approximate relationship between measured array cross-spectra and a small number of parameters that describe the incident wave properties and the reflectivity of the structure. Model tests with ...

  16. Selectively reflective transparent sheets

    Science.gov (United States)

    Waché, Rémi; Florescu, Marian; Sweeney, Stephen J.; Clowes, Steven K.

    2015-08-01

    We investigate the possibility to selectively reflect certain wavelengths while maintaining the optical properties on other spectral ranges. This is of particular interest for transparent materials, which for specific applications may require high reflectivity at pre-determined frequencies. Although there exist currently techniques such as coatings to produce selective reflection, this work focuses on new approaches for mass production of polyethylene sheets which incorporate either additives or surface patterning for selective reflection between 8 to 13 μ m. Typical additives used to produce a greenhouse effect in plastics include particles such as clays, silica or hydroxide materials. However, the absorption of thermal radiation is less efficient than the decrease of emissivity as it can be compared with the inclusion of Lambertian materials. Photonic band gap engineering by the periodic structuring of metamaterials is known in nature for producing the vivid bright colors in certain organisms via strong wavelength-selective reflection. Research to artificially engineer such structures has mainly focused on wavelengths in the visible and near infrared. However few studies to date have been carried out to investigate the properties of metastructures in the mid infrared range even though the patterning of microstructure is easier to achieve. We present preliminary results on the diffuse reflectivity using FDTD simulations and analyze the technical feasibility of these approaches.

  17. Thoughts on Reflection (Editorial

    Directory of Open Access Journals (Sweden)

    Denise Koufogiannakis

    2010-06-01

    Full Text Available There has been some acknowledgement in the published literature that reflection is a crucial element of the evidence based library and information practice (EBLIP model we have adopted (Booth 2004, 2006; Grant 2007; Helliwell 2007. As we work through a problem and try to incorporate the best available evidence into our decision making, reflection is required at several stages, including the very identification of the problem through to our assessment of the process itself and what we have learned in order to inform future practice. However, reflection and reflective writing have not fully been integrated into the process we espouse, and very little has been done to look more closely at this element of the model and how it can be integrated into professional learning.In a recently published research article, Sen (2010 confirms the relationship between reflection and several aspects of professional practice. These include critical review and decision making, two aspects that are tied closely to the evidence based process. Sen notes: Students were more likely to show evidence of learning, self‐development, the ability to review issues crucially, awareness of their own mental functions, ability to make decision [sic] and being empowered when they had mastered the art of reflective practice and the more deeply analytical reflective writing. (p.84 EBLIP (the journal tries to incorporate elements of reflection within the articles we publish. While we clearly believe in the need for our profession to do quality research and publish that research so that it can be accessible to practitioners, we also know that research cannot be looked at in isolation. Our evidence summaries are one way of reflecting critically on previously published research, and in the same vein, our classics bring older research studies back to the foreground. This work needs to continue to be discussed and looked at for its impact on our profession.More directly, the Using

  18. A study of the anti-reflection efficiency of natural nano-arrays of varying sizes

    International Nuclear Information System (INIS)

    Sun Mingxia; Liang Aiping; Zheng Yongmei; Watson, Gregory S; Watson, Jolanta A

    2011-01-01

    The dependence of optical reflectivity and wettability on the surface topography of 32 species of cicada wing membranes has been investigated using UV-visible spectrophotometry, contact angle measurements and environmental scanning electron microscopy. The nanoscale hexagonally close packed protrusions have been shown to exhibit an anti-reflection and in some cases an anti-wetting function. The parameters of the structures were measured to be 77-148 nm in diameter, 44-117 nm in spacing and 159-481 nm in height. The transmittance spectrum and static contact angles were measured. At a wavelength range of 500-2500 nm, only minor differences in the anti-reflection performance were observed for each cicada species ascribed to the mechanism of impedance matching between cuticle and air. The transmittance properties of cicada wings were altered successfully through the scanning probe microscope-based manipulation by reducing the protrusion height via the contact mode. A near linear dependence was found between a decrease in protuberance height and a resulting increase in reflectance intensity. A diversity of wettability was observed with contact angles varying from 56.5 0 to 146.0 0 . Both effects of anti-reflection and wettability are dependent on the height of protrusions. The anti-reflection is insensitive when the wavelength is larger than the lateral feature size of the nanostructure. The stronger hydrophobic properties are generally associated with a larger diameter, closer spacing and greater height of protrusions when the wing membrane is intact.

  19. Respiratory Information Extraction from Electrocardiogram Signals

    KAUST Repository

    Amin, Gamal El Din Fathy

    2010-01-01

    The Electrocardiogram (ECG) is a tool measuring the electrical activity of the heart, and it is extensively used for diagnosis and monitoring of heart diseases. The ECG signal reflects not only the heart activity but also many other physiological

  20. Radar reflection off extensive air showers

    Directory of Open Access Journals (Sweden)

    Werner F.

    2013-06-01

    Full Text Available We investigate the possibility of detecting extensive air showers by the radar technique. Considering a bistatic radar system and different shower geometries, we simulate reflection of radio waves off the static plasma produced by the shower in the air. Using the Thomson cross-section for radio wave reflection, we obtain the time evolution of the signal received by the antennas. The frequency upshift of the radar echo and the power received are studied to verify the feasibility of the radar detection technique.

  1. Temporal processes involved in simultaneous reflection masking

    DEFF Research Database (Denmark)

    Buchholz, Jörg

    2006-01-01

    reflection delays and enhances the test reflection for large delays. Employing a 200-ms-long broadband noise burst as input signal, the critical delay separating these two binaural phenomena was found to be 7–10 ms. It was suggested that the critical delay refers to a temporal window that is employed......, resulting in a critical delay of about 2–3 ms for 20-ms-long stimuli. Hence, for very short stimuli the temporal window or critical delay exhibits values similar to the auditory temporal resolution as, for instance, observed in gap-detection tasks. It is suggested that the larger critical delay observed...

  2. Creation, Identity and Reflection

    Directory of Open Access Journals (Sweden)

    Alina Beatrice Cheşcă

    2015-05-01

    Full Text Available The paper “Creation, Identity and Reflection” approaches the identification in the “mirror” of reality with creation, in other words seeking the authors’ identity in the reflected images. Reflection means attempting to find oneself, the mirror being the main principle of creation. Many characters become interesting only when they step into the world beyond the mirror, when their faces are doubled by the other self or when their selves are returned by other characters. The narcissistic concept of the mirror, i.e. the reflection in the mirror and the representation of the mirror itself, is a recurrent one in literature, but the reflection of the self which is not the self (as it is a reflection does not necessarily appear in a mirror or in a photograph or portrait. Sometimes, the not-self is returned to the self by another person or character. As far as Oscar Wilde’s theories are concerned, the main idea is that people are interesting for their masks, not for their inner nature. What Wilde calls “inner nature” is the characters’ un-reflected self and the mask is the reflection, the self in the mirror. Some characters’ relationships develop within a fiction that they dramatically try to preserve and protect with the risk of suffering. They refuse to take off the masks which define them in the others’ minds and hearts; the narcissistic individuals (both artists and characters seek and love their own image which they project upon facts, thus creating a fictive realm.

  3. Ultraviolet signals in birds are special.

    OpenAIRE

    Hausmann, Franziska; Arnold, Kathryn E; Marshall, N Justin; Owens, Ian P F

    2003-01-01

    Recent behavioural experiments have shown that birds use ultraviolet (UV)-reflective and fluorescent plumage as cues in mate choice. It remains controversial, however, whether such UV signals play a special role in sexual communication, or whether they are part of general plumage coloration. We use a comparative approach to test for a general association between sexual signalling and either UV-reflective or fluorescent plumage. Among the species surveyed, 72% have UV colours and there is a si...

  4. Phobos - Spectrophotometry between 0.3 and 0.6 micron and IR-radiometry

    Science.gov (United States)

    Ksanfomality, L.; Murchie, S.; Britt, D.; Fisher, P.; Duxbury, T.

    1991-01-01

    A 0.3 - 0.6 micron UV-visible spectrophotometer and a 5 - 50 micron radiometer in the KRFM experiment on Phobos 2 measured two groundtracks in the equatorial region of Phobos. Preliminary results indicate that three surface units can be recognized on the basis of differing UV-visible spectral reflectance properties. One of the units is most comparable spectrally to optically darkened mafic material, and a second is comparable either to anhydrous carbonaceous chondrite or to blackened mafic material. Spectral properties of the third unit do not resemble those of known meteorite types. Brightness temperatures measured by the radiometer are consistent with a typical surface thermal inertia of 1 - 3 x 10 to the -3 cal/(sq cm deg s exp 1/2), as suggested by previous investigations, implying a lunar-like regolith texture. At least one area of possibly higher thermal inertia has been tentatively identified, where a large degraded crater is crossed by several grooves. These results indicate significant lateral heterogeneity in the optical and textural properties of Phobos' surface.

  5. Prediction of the oversulphated chondroitin sulphate contamination of unfractionated heparin by ATR-IR spectrophotometry.

    Science.gov (United States)

    Norwig, J; Beyer, T; Brinz, D; Holzgrabe, U; Diller, M; Manns, D

    2009-03-01

    The detection of a contamination of heparin with oversulphated chondroitin sulphate (OSCS) was first analysed in an unfractionated heparin batch supplied to the US API-market in April 2006. OSCS is a semi-synthetic derivative of the natural occuring glycosaminoglycan chondroitin sulphate. Moreover some spectroscopic characteristics of the substance overlap with those of heparin, so that the infrared (IR) spectra are visually difficult to distinguish whereas (1)H-NMR (Nuclear Magnetic Resonance) spectroscopy or capillary electrophoresis (CE) provides identification by a simple visual inspection of either the spectrum or the electropherogram respectively. However, applying special tools of Multivariate Data Analysis (MVA) to the IR spectra an identification of the contaminated samples is possible. In detail a rapid Attenuation Total Reflectance-Infrared (ATR-IR) measurement was selected, which does not require any sample preparation. The result (contaminated or not contaminated) is predicted within a few minutes. A method transfer to mobile ATR-IR spectrometers seems to be possible. The analysis is based on the fact that the fingerprint of the OSCS IR spectrum (1st derivative) complies with a theoretically calculated principal component in the MVA.

  6. Single-laboratory evaluation of SW-846 Methods 7090/7091 determination of beryllium by flame and furnace atomic absorption spectrophotometry. Summary report January-August 1987

    International Nuclear Information System (INIS)

    Hodge, V.F.; Darby, D.A.; Thompson, W.E.; Jones, C.L.

    1988-02-01

    The results of a single-laboratory study of the Determination of Beryllium by Flame and Furnace Atomic Absorption Spectrophotometry, are described. The study examined the application of these two powerful beryllium detection methods to the analysis of selected liquid and solid samples after digestion by appropriate SW-846 methods. Method performance data including detection limits, optimum concentration ranges (linearity), spike recoveries, interferences, precision, accuracy, and optimum operating parameters are presented and discussed

  7. KAJIAN ADSORPSI ION LOGAM Cr(VI OLEH ADSORBEN KOMBINASI ARANG AKTIF SEKAM PADI DAN ZEOLIT MENGGUNAKAN METODE SOLID-PHASE SPECTROPHOTOMETRY (SPS

    Directory of Open Access Journals (Sweden)

    Sulistyo Saputro

    2016-10-01

      This study aims to study the use of activated rice husk charcoal and zeolite as combination adsorbents to adsorb Cr(VI metal ions; the effect of the combination adsorbents of activated rice husk charcoal and zeolite’s compositions to adsorb Cr(VI metal ions; and the sensitivity of solid-phase spectrophotometry (SPS as a method to determine the reduced levels of Cr(VI metal ions in the level of 15μ"> g/L. The activated rice husk charcoal used were obtained through the activation process by soaking in a solution of ZnCl2 10% while the zeolite with a solution of H2SO4 10%. The contacting process of the adsorbents with Cr(VI metal ions was done by varying the compositions of the activated rice husk charcoal and zeolite adsorbent, 1:1, 1:2, 1:3, and 2:1. The data analysis of the Cr(VI level used solid-phase spectrophotometry (SPS method. Characterization of activated rice husk charcoal and zeolite used FTIR. The results showed that: (1 a combination of activated rice husk charcoal and zeolite can be used as adsorbent to adsorb Cr(VI metal ions with the adsorption capacity was 0,28 15μ"> g/g; (2 the optimum composition of adsorbents was 1:2 with the percentage of absorption was 40,99%; (3 solid-phase spectrophotometry (SPS is a sensitive method to determine the reduced levels of Cr(VI in the level of 15μ"> g/L with the limit of detection (LOD was 0,021 15μ"> g/L.   Keywords: adsorption, Cr(VI,  activated  rice husk charcoal,  zeolite, solid-phase spectrophotometry

  8. Signal Processing

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Signal processing techniques, extensively used nowadays to maximize the performance of audio and video equipment, have been a key part in the design of hardware and software for high energy physics detectors since pioneering applications in the UA1 experiment at CERN in 1979

  9. PHASES: Opto-mechanical solutions to perform absolute spectrophotometry from space

    Directory of Open Access Journals (Sweden)

    Vather Dinesh

    2013-04-01

    Full Text Available This work provides an update of the current status of PHASES, which is a project aimed at developing a space-borne telescope to perform absolute flux calibrated spectroscopy of bright stars. PHASES will make it possible to measure micromagnitude photometric variations due to, e.g., exo-planet/moon transits. It is designed to obtain 1% RMS flux calibrated low resolution spectra in the wavelength range 370–960 nm with signal-to-noise ratios >100 for stars with V<10 in short integration times of ∼1 minute. The strategy to calibrate the system using A-type stars is outlined. PHASES will make possible a complete characterization of stars, some of them hosting planets. From the comparison of observed spectra with accurate model atmospheres stellar angular diameters will be determined with precisions of ∼0.5%. The light curves of transiting systems will be then used to extract the radius of the planet with similar precision. The demanding scientific requirements to be achieved under extreme observing conditions have shaped the optomechanical design. A computational model and a high-precision interferometric system have been developed to test the performance of the instrument.

  10. Biology Reflective Assessment Curriculum

    Science.gov (United States)

    Bayley, Cheryl Ann

    Often students and educators view assessments as an obligation and finality for a unit. In the current climate of high-stakes testing and accountability, the balance of time, resources and emphasis on students' scores related to assessment have been slanted considerably toward the summative side. This tension between assessment for accountability and assessment to inform teaching strains instruction and educators' ability to use that information to design learning opportunities that help students develop deeper conceptual understanding. A substantive body of research indicates that formative and reflective assessment can significantly improve student learning. Biology Reflective Assessment Curriculum (BRAC) examines support provided for high school science students through assessment practices. This investigation incorporates the usage of reflective assessments as a guiding practice for differentiated instruction and student choice. Reflective assessment is a metacognitive strategy that promotes self-monitoring and evaluation. The goals of the curriculum are to promote self-efficacy and conceptual understanding in students learning biology through developing their metacognitive awareness. BRAC was implemented in a high school biology classroom. Data from assessments, metacognitive surveys, self-efficacy surveys, reflective journals, student work, a culminating task and field notes were used to evaluate the effectiveness of the curriculum. The results suggest that students who develop their metacognitive skills developed a deeper conceptual understanding and improved feelings of self-efficacy when they were engaged in a reflective assessment unit embedded with student choice. BRAC is a tool for teachers to use assessments to assist students in becoming metacognitive and to guide student choice in learning opportunities.

  11. Inter-laboratory verification of European pharmacopoeia monograph on derivative spectrophotometry method and its application for chitosan hydrochloride.

    Science.gov (United States)

    Marković, Bojan; Ignjatović, Janko; Vujadinović, Mirjana; Savić, Vedrana; Vladimirov, Sote; Karljiković-Rajić, Katarina

    2015-01-01

    Inter-laboratory verification of European pharmacopoeia (EP) monograph on derivative spectrophotometry (DS) method and its application for chitosan hydrochloride was carried out on two generation of instruments (earlier GBC Cintra 20 and current technology TS Evolution 300). Instruments operate with different versions of Savitzky-Golay algorithm and modes of generating digital derivative spectra. For resolution power parameter, defined as the amplitude ratio A/B in DS method EP monograph, comparable results were obtained only with algorithm's parameters smoothing points (SP) 7 and the 2nd degree polynomial and those provided corresponding data with other two modes on TS Evolution 300 Medium digital indirect and Medium digital direct. Using quoted algorithm's parameters, the differences in percentages between the amplitude ratio A/B averages, were within accepted criteria (±3%) for assay of drug product for method transfer. The deviation of 1.76% for the degree of deacetylation assessment of chitosan hydrochloride, determined on two instruments, (amplitude (1)D202; the 2nd degree polynomial and SP 9 in Savitzky-Golay algorithm), was acceptable, since it was within allowed criteria (±2%) for assay deviation of drug substance, for method transfer in pharmaceutical analyses. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Can tissue spectrophotometry and laser Doppler flowmetry help to identify patients at risk for wound healing disorders after neck dissection?

    Science.gov (United States)

    Rohleder, Nils H; Flensberg, Sandra; Bauer, Florian; Wagenpfeil, Stefan; Wales, Craig J; Koerdt, Steffen; Wolff, Klaus D; Hölzle, Frank; Steiner, Timm; Kesting, Marco R

    2014-03-01

    Microcirculation and oxygen supply in cervical skin were measured with an optical, noninvasive method in patients with or without radiotherapy before neck dissection. The course of wound healing was monitored after the surgical procedure to identify predictive factors for postoperative wound healing disorders. Tissue spectrophotometry and laser Doppler flowmetry were used to determine capillary oxygen saturation, hemoglobin concentration, blood flow, and blood velocity at 2-mm and 8-mm depths in the cervical skin of 91 patients before neck dissection in a maxillofacial unit of a university hospital in Munich, Germany. Parameters were evaluated for differences between patients with irradiation (24) and without (67) and patients with wound healing disorders (25) and without (66) (univariate or multivariate statistical analyses). Velocity at 2 mm was lower in irradiated skin (P = .016). Flow at 2 mm was higher in patients with wound healing disorders (P = .018). High flow values could help to identify patients at risk for cervical wound healing disorders. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry.

    Science.gov (United States)

    Amin, Alaa S; El-Sharjawy, Abdel-Azeem M; Kassem, Mohammed A

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L(-1) of Tl(III) with relative standard deviation (RSD) of 1.40% (n=10). The detection and quantification limits are 150 and 495 ng L(-1) using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31×10(7) L mol(-1)cm(-1) and 0.00156 ng cm(-2), respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. An optical investigation of dentinal discoloration due to commonly endodontic sealers, using the transmitted light polarizing microscopy and spectrophotometry.

    Science.gov (United States)

    Suciu, Ioana; Ionescu, Ecaterina; Dimitriu, Bogdan Alexandru; Bartok, Ruxandra Ioana; Moldoveanu, Georgiana Florentina; Gheorghiu, Irina Maria; Suciu, Ileana; Ciocîrdel, Mihai

    2016-01-01

    The aim of this study was to establish the degree of tooth crown staining by commonly used endodontic sealers. Crown discolorations by tooth canal sealers [AH Plus (Dentsply DeTrey Gmbh, Konstanz, Germany); Endofill (Produits Dentaires SA, Vevey, Switzerland); Apexit (Dentsply DeTrey Gmbh, Konstanz, Germany); and MTA Fillapex (Angelus, Londrina, Brazil)] were tested on extracted human premolars. The samples were divided into five groups of five samples each, after root canal sealing. Five teeth were used as control groups. The spectrophotometric method was performed in order to quantify in terms of color change of the coronal part (it was also recorded a track on how the color changes over time). For the microscopic study of the extracted dental specimens subjected to this study, polarized transmitted light microscopy was used. This method involves the development of special microscopic preparations, called "thin sections". In our case, the thin section was performed on 20 prepared and obturated recently extracted teeth. The degree of discoloration was determined after one week and three months using spectrophotometry and polarized light microscopy. All sealers usually cause some degree of discoloration on the cervical aspect of the crowns that increases in time. AH Plus and Endofill caused the greatest discoloration, followed by Apexit and MTA Fillapex.

  15. Determination of carcinogenic herbicides in milk samples using green non-ionic silicone surfactant of cloud point extraction and spectrophotometry.

    Science.gov (United States)

    Mohd, N I; Zain, N N M; Raoov, M; Mohamad, S

    2018-04-01

    A new cloud point methodology was successfully used for the extraction of carcinogenic pesticides in milk samples as a prior step to their determination by spectrophotometry. In this work, non-ionic silicone surfactant, also known as 3-(3-hydroxypropyl-heptatrimethylxyloxane), was chosen as a green extraction solvent because of its structure and properties. The effect of different parameters, such as the type of surfactant, concentration and volume of surfactant, pH, salt, temperature, incubation time and water content on the cloud point extraction of carcinogenic pesticides such as atrazine and propazine, was studied in detail and a set of optimum conditions was established. A good correlation coefficient ( R 2 ) in the range of 0.991-0.997 for all calibration curves was obtained. The limit of detection was 1.06 µg l -1 (atrazine) and 1.22 µg l -1 (propazine), and the limit of quantitation was 3.54 µg l -1 (atrazine) and 4.07 µg l -1 (propazine). Satisfactory recoveries in the range of 81-108% were determined in milk samples at 5 and 1000 µg l -1 , respectively, with low relative standard deviation, n  = 3 of 0.301-7.45% in milk matrices. The proposed method is very convenient, rapid, cost-effective and environmentally friendly for food analysis.

  16. Formaldehyde in Alcoholic Beverages: Large Chemical Survey Using Purpald Screening Followed by Chromotropic Acid Spectrophotometry with Multivariate Curve Resolution

    Directory of Open Access Journals (Sweden)

    Julien A. Jendral

    2011-01-01

    Full Text Available A strategy for analyzing formaldehyde in beer, wine, spirits, and unrecorded alcohol was developed, and 508 samples from worldwide origin were analyzed. In the first step, samples are qualitatively screened using a simple colorimetric test with the purpald reagent, which is extremely sensitive for formaldehyde (detection limit 0.1 mg/L. 210 samples (41% gave a positive purpald reaction. In the second step, formaldehyde in positive samples is confirmed by quantitative spectrophotometry of the chromotropic acid-formaldehyde derivative combined with Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS. Calculation of UV-VIS and 13C NMR spectra confirmed the monocationic dibenzoxanthylium structure as the product of the reaction and disproved the widely cited para,para-quinoidal structure. Method validation for the spectrophotometric procedure showed a detection limit of 0.09 mg/L and a precision of 4.2–8.2% CV. In total, 132 samples (26% contained formaldehyde with an average of 0.27 mg/L (range 0–14.4 mg/L. The highest incidence occurred in tequila (83%, Asian spirits (59%, grape marc (54%, and brandy (50%. Our survey showed that only 9 samples (1.8% had formaldehyde levels above the WHO IPCS tolerable concentration of 2.6 mg/L.

  17. UV-visible scanning spectrophotometry and chemometric analysis as tools for carotenoids analysis in cassava genotypes (Manihot esculenta Crantz).

    Science.gov (United States)

    Moresco, Rodolfo; Uarrota, Virgílio G; Pereira, Aline; Tomazzoli, Maíra; Nunes, Eduardo da C; Martins Peruch, Luiz Augusto; Gazzola, Jussara; Costa, Christopher; Rocha, Miguel; Maraschin, Marcelo

    2015-12-01

    In this study, the metabolomics characterization focusing on the carotenoid composition of ten cassava (Manihot esculenta) genotypes cultivated in southern Brazil by UV-visible scanning spectrophotometry and reverse phase-high performance liquid chromatography was performed. Cassava roots rich in β-carotene are an important staple food for populations with risk of vitamin A deficiency. Cassava genotypes with high pro-vitamin A activity have been identified as a strategy to reduce the prevalence of deficiency of this vitamin. The data set was used for the construction of a descriptive model by chemometric analysis. The genotypes of yellow-fleshed roots were clustered by the higher concentrations of cis- β-carotene and lutein. Inversely, cream-fleshed roots genotypes were grouped precisely due to their lower concentrations of these pigments, as samples rich in lycopene (redfleshed) differed among the studied genotypes. The analytical approach (UV-Vis, HPLC, and chemometrics) used showed to be efficient for understanding the chemodiversity of cassava genotypes, allowing to classify them according to important features for human health and nutrition.

  18. The determination, by atomic-absorption spectrophotometry using electrothermal atomization, of platinum, palladium, rhodium, ruthenium, and iridium

    International Nuclear Information System (INIS)

    Haines, J.; Robert, R.V.D.

    1982-01-01

    A method that involves measurement by atomic-absorption spectrophotometry using electrothermal atomization has been developed for the determination of trace quantities of platinum, palladium, rhodium, ruthenium, and iridium in mineralogical samples. The elements are separated and concentrated by fusion, nickel sulphide being used as the collector, and the analyte elements are measured in the resulting acid solution. An organic extraction procedure was found to offer no advantages over the proposed method. Mutual interferences between the five platinum-group metals examined, as well as interferences from gold, silver, and nickel were determined. The accuracy of the measurement was established by the analysis of a platinum-ore reference material. The lower limits of determination of each of the analyte elements in a sample material are as follows: platinum 1,6μg/l, palladium 0,2μg/1, rhodium 0,5μg/l, ruthenium 3μg/l, and iridium 2,5μg/l. The relative standard deviations range from 0,05 for rhodium to 0.08 for iridium. The method, which is described in detail in the Appendix, is applicable to the determination of these elements in ores, tailings, and geological materials in which the total concentration of the noble metals is less than 1g/t

  19. Evaluation of various techniques for the pretreatment of sewage sludges prior to trace metal analysis by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Smith, R.

    1983-01-01

    Six techniques were evaluated for their suitability for the pretreatment of dried sewage sludge prior to trace metal analysis by atomic absorption spectrophotometry. The evaluation comprised analysis of two prepared samples of dried sludge for aluminium, cadmium, chromium, copper, iron, lead, manganese, nickel and zinc, after the following pretreatment: dry ashing at 500 degrees Celsius followed by extraction with dilute hydrochloric acid; dry ashing at 500 degrees Celsius followed by extraction with aqua regia; nitric acid digestion followed by extraction with hydrochloric acid; extraction with aqua regia; ashing with magnesium nitrate solution at 550 degrees Celsius followed by digestion with hydrochloric acid and extraction with nitric acid; extraction with nitric acid. Procedures involving the use of perchloric acid, hydrofluoric acid and hydrogen peroxide were not considered for reasons of safety. Except in the case of aluminium the direct mineral acid digestion and/or extraction methods generally gave higher recoveries than the procedures incorporating an ashing step. Direct extraction of the sample with aqua regia was recommended as a rapid and simple general method of sample pretreatment prior to analysis for all the metals investigated except aluminium. For this metal, more drastic sample pretreatment will be required, for example fusion or hydrofluoric acid digestion

  20. Retinopathy of prematurity and induced changes in arterial oxygen saturation with near infrared spectrophotometry: a retrospective cohort study

    Science.gov (United States)

    von Siebenthal, K.; Keel, M.; Dietz, V.; Fauchere, J. C.; Martin, X.; Wolf, Martin; Duc, G.; Bucher, H. U.

    1996-10-01

    Near-infrared spectrophotometry (NIRS) is a noninvasive method for measuring oxygenated and deoxygenated hemoglobin in the neonatal brain. Using oxygen as a tracer, it is possible to calculate cerebral blood flow (cbf) and hemoglobin concentration (cHbc), which corresponds to cerebral blood volume, by inducing small changes in arterial oxygen saturation. Variability of tcpO2 is considered to be associated with severe retinopathy of prematurity (ROP). A preliminary analysis without control found a 51 percent incidence of ROP in infants subjected to NIRS measurements whereas among infants who were not exposed to oxygen changes, only 29 percent developed ROP. A controlled study with matched pairs was performed. Thirty-nine premature newborns who had received NIRS recordings were matched with 39 out of 172 infants who had not received NIRS. Using this controlled study design there was no difference in the incidence and severity of ROP between the two groups. The conclusions are that: 1) small changes in oxygen saturation of 3 to 10 percent to measure cbf and cHbc did not increase the incidence or the degree of severity of ROP. 2) A controlled study design is important. Analyses of uncontrolled data would have led to the conclusion that oxygen changes as used with NIRS increase the risk of ROP.

  1. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry

    Science.gov (United States)

    Amin, Alaa S.; El-Sharjawy, Abdel-Azeem M.; Kassem, Mohammed A.

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L-1 of Tl(III) with relative standard deviation (RSD) of 1.40% (n = 10). The detection and quantification limits are 150 and 495 ng L-1 using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31 × 107 L mol-1 cm-1 and 0.00156 ng cm-2, respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.

  2. Formaldehyde in alcoholic beverages: large chemical survey using purpald screening followed by chromotropic Acid spectrophotometry with multivariate curve resolution.

    Science.gov (United States)

    Jendral, Julien A; Monakhova, Yulia B; Lachenmeier, Dirk W

    2011-01-01

    A strategy for analyzing formaldehyde in beer, wine, spirits, and unrecorded alcohol was developed, and 508 samples from worldwide origin were analyzed. In the first step, samples are qualitatively screened using a simple colorimetric test with the purpald reagent, which is extremely sensitive for formaldehyde (detection limit 0.1 mg/L). 210 samples (41%) gave a positive purpald reaction. In the second step, formaldehyde in positive samples is confirmed by quantitative spectrophotometry of the chromotropic acid-formaldehyde derivative combined with Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS). Calculation of UV-VIS and (13)C NMR spectra confirmed the monocationic dibenzoxanthylium structure as the product of the reaction and disproved the widely cited para,para-quinoidal structure. Method validation for the spectrophotometric procedure showed a detection limit of 0.09 mg/L and a precision of 4.2-8.2% CV. In total, 132 samples (26%) contained formaldehyde with an average of 0.27 mg/L (range 0-14.4 mg/L). The highest incidence occurred in tequila (83%), Asian spirits (59%), grape marc (54%), and brandy (50%). Our survey showed that only 9 samples (1.8%) had formaldehyde levels above the WHO IPCS tolerable concentration of 2.6 mg/L.

  3. High-performance liquid chromatography and derivative spectrophotometry for simultaneous determination of pravastatin and fenofibrate in the dosage form

    Directory of Open Access Journals (Sweden)

    Hefnawy Mohamed M.

    2014-12-01

    Full Text Available High performance liquid chromatography (HPLC and second-order derivative spectrophotometry have been used for simultaneous determination of pravastatin (PS and fenofibrate (FF in pharmaceutical formulations. HPLC separation was performed on a phenyl HYPERSIL C18 column (125 mm × 4.6 mm i.d., 5 μm particle diameter in the isocratic mode using a mobile phase acetonitrile/0.1 % diethyl amine (50:50, V/V, pH 4.5 pumped at a flow rate of 1.0 mL min-1. Measurement was made at 240 nm. Both drugs were well resolved on the stationary phase, with retention times of 2.15 and 5.79 min for PS and FF, respectively. Calibration curves were linear (R = 0.999 for PS and 0.996 for FF in the concentration range of 5-50 and 20-200 µg mL-1 for PS and FF, respectively. Pravastatin and fenofibrate were quantitated in combined preparations also using the second-order derivative response at 237.6 and 295.1 nm for PS and FF, respectively. Calibration curves were linear, with the correlation coefficient R = 0.999 for pravastatin and fenofibrate, in the concentration range of 5-20 and 3-20 µg mL-1 for PS and FF, respectively. Both methods were fully validated and compared, the results confirmed that they were highly suitable for their intended purpose.

  4. Predicting heavy metal concentrations in soils and plants using field spectrophotometry

    Science.gov (United States)

    Muradyan, V.; Tepanosyan, G.; Asmaryan, Sh.; Sahakyan, L.; Saghatelyan, A.; Warner, T. A.

    2017-09-01

    Aim of this study is to predict heavy metal (HM) concentrations in soils and plants using field remote sensing methods. The studied sites were an industrial town of Kajaran and city of Yerevan. The research also included sampling of soils and leaves of two tree species exposed to different pollution levels and determination of contents of HM in lab conditions. The obtained spectral values were then collated with contents of HM in Kajaran soils and the tree leaves sampled in Yerevan, and statistical analysis was done. Consequently, Zn and Pb have a negative correlation coefficient (p regression models and artificial neural network (ANN) for HM prediction were developed. Good results were obtained for the best stress sensitive spectral band ANN (R2 0.9, RPD 2.0), Simple Linear Regression (SLR) and Partial Least Squares Regression (PLSR) (R2 0.7, RPD 1.4) models. Multiple Linear Regression (MLR) model was not applicable to predict Pb and Zn concentrations in soils in this research. Almost all full spectrum PLS models provide good calibration and validation results (RPD>1.4). Full spectrum ANN models are characterized by excellent calibration R2, rRMSE and RPD (0.9; 0.1 and >2.5 respectively). For prediction of Pb and Ni contents in plants SLR and PLS models were used. The latter provide almost the same results. Our findings indicate that it is possible to make coarse direct estimation of HM content in soils and plants using rapid and economic reflectance spectroscopy.

  5. Self-Reflection

    DEFF Research Database (Denmark)

    Fausing, Bent

    2018-01-01

    Reflecting has a double meaning, mirroring and thinking. The seminar will investigate how these two meanings intervene in each other. As we perceive we are already in pre-refectory state, and thinking involves a lot of not only thoughts, but also of senses and sensing, wherefrom our thoughts star...

  6. Worship, Reflection, Empirical Research

    OpenAIRE

    Ding Dong,

    2012-01-01

    In my youth, I was a worshipper of Mao Zedong. From the latter stage of the Mao Era to the early years of Reform and Opening, I began to reflect on Mao and the Communist Revolution he launched. In recent years I’ve devoted myself to empirical historical research on Mao, seeking the truth about Mao and China’s modern history.

  7. Wave Reflection Model Tests

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Larsen, Brian Juul

    The investigation concerns the design of a new internal breakwater in the main port of Ibiza. The objective of the model tests was in the first hand to optimize the cross section to make the wave reflection low enough to ensure that unacceptable wave agitation will not occur in the port. Secondly...

  8. Reflections on 21 years

    International Nuclear Information System (INIS)

    Eklund, S.; Mandel, H.; Teller, E.

    1977-01-01

    Personal reflections after twenty one years of nuclear power are presented by a number of those who were international figures in the nuclear energy field during that period. Lessons learnt, achievements, prospects and predictions for the future are discussed in eleven brief surveys. (U.K.)

  9. Reflection by Porro Prisms

    Science.gov (United States)

    Greenslade, Thomas B.

    2010-04-01

    Students all know that reflection from a plane mirror produces an image that is reversed right to left and so cannot be read by anyone but Leonardo da Vinci, who kept his notes in mirror writing. A useful counter-example is the Porro prism, which produces an image that is not reversed.

  10. Value reflected health education

    DEFF Research Database (Denmark)

    Wistoft, Karen; Nordentoft, Helle Merete

    2011-01-01

    This article examines the impact of a value-reflected approach in health education by demonstrating the nature of professional competence development connected to this approach. It is based on findings from two three-year health educational development projects carried out by school health nurses...... develop pedagogical competences in health education improving school childrens’ health....

  11. Reflection on Political Representation

    DEFF Research Database (Denmark)

    Kusche, Isabel

    2017-01-01

    This article compares how Members of Parliament in the United Kingdom and Ireland reflect on constituency service as an aspect of political representation. It differs from existing research on the constituency role of MPs in two regards. First, it approaches the question from a sociological viewp...

  12. Onward: Reflections on Mentoring

    Science.gov (United States)

    Williams, Kimberley Buster

    2018-01-01

    The author has been blessed with great mentors throughout her career. When she was invited to participate in the Leadership University of Mary Washington (UMW), a mentoring program at her institution, she did not hesitate to say yes. In this article, the author shares her reflections on mentoring.

  13. Interferometric reflection moire

    Science.gov (United States)

    Sciammarella, Cesar A.; Combell, Olivier

    1995-06-01

    A new reflection moire technique is introduced in this paper. The basic equations that relate the measurement of slopes to the basic geometric and optical parameters of the system are derived. The sensitivity and accuracy of the method are discussed. Examples of application to the study of silicon wafers and electronic chips are given.

  14. Reflection on robotic intelligence

    NARCIS (Netherlands)

    Bartneck, C.

    2006-01-01

    This paper reflects on the development or robots, both their physical shape as well as their intelligence. The later strongly depends on the progress made in the artificial intelligence (AI) community which does not yet provide the models and tools necessary to create intelligent robots. It is time

  15. Reflections on "La Esperanza"

    Science.gov (United States)

    Cortez, Anita

    2007-01-01

    The author was recently asked to reflect on her "educational journey." As far as she can remember she has been hungry to learn. A friend once described her as having "hambres atrasadas," which he described as a kind of "hunger nipping at her heels." It goes back, of course, to her parents: Her father's and her early…

  16. Reflecting on Writing Autobiography

    Science.gov (United States)

    Begg, Andy

    2011-01-01

    The following reflections relate to the reasons for and an approach to an autobiographic task, the notions that underpin it, and some thoughts about the quality and value of such a project. The focus was on the ways one views curriculum change over time; and the intention was to provide an example that others may sense as either familiar or at…

  17. Reflections on the Field.

    Science.gov (United States)

    Kauffman, James M.

    2003-01-01

    Reflections on the field of special education offer six ideas: (1) the value of science; (2) the continuing value of separate and special education for some students; (3) the continuing importance of prevention; (4) the importance of academic instruction; (5) the importance of social justice for the poor; and (6) a renewed emphasis on human…

  18. Reflections, 15 Years Later

    Science.gov (United States)

    Knox, George

    2016-01-01

    George Knox reflects on his 15-year career as president of Labette Community College in Parsons, Kansas. Knox writes that, as a first-time president coming into a brand new system, he was very fortunate to have many seasoned presidents and mentors in Kansas and from the American Association of Community Colleges' (AACC) Presidents Academy. He says…

  19. Concept for phase-to-intensity conversion in SOAs by facet reflections

    DEFF Research Database (Denmark)

    Blaaberg, Søren; Mørk, Jesper

    2010-01-01

    All-optical conversion from phase-modulated signals to intensity-modulated signals is theoretically demonstrated in semiconductor optical amplifiers (SOAs). Large-signal and small-signal calculations show significant conversion responses appearing as a result of even minute reflections at the end...... mirrors of the SOA. It is discussed how reflected phase-modulated signals can lead to interference resulting in intensity fluctuations that are amplified by the gain in a SOA. The effect can be utilized for deliberate conversion between optical modulation formats.......All-optical conversion from phase-modulated signals to intensity-modulated signals is theoretically demonstrated in semiconductor optical amplifiers (SOAs). Large-signal and small-signal calculations show significant conversion responses appearing as a result of even minute reflections at the end...

  20. Being a reflective teacher——reflection on group management

    Institute of Scientific and Technical Information of China (English)

    Pan; Lehui

    2015-01-01

    <正>Introduction According to Pollard and Triggs(1997),reflective teaching is a process through which the capacity to make such professional judgments can be developed and maintained.Then what is a reflective teacher?Reflective teacher is someone who reflects systematically on her practice in a constant attempt to improve

  1. Ethical reflection and psychotherapy.

    Science.gov (United States)

    Vyskocilová, Jana; Prasko, Jan

    2013-01-01

    Theories of ethics and ethical reflection may be applied to both theory and practice in psychotherapy. There is a natural affinity between ethics and psychotherapy. Psychotherapy practice is concerned with human problems, dilemmas and emotions related to both one's own and other people's values. Ethics is also concerned with dilemmas in human thinking and with how these dilemmas reflect other individuals' values. Philosophical reflection itself is not a sufficient basis for the ethics of psychotherapy but it may aid in exploring attitudes related to psychotherapy, psychiatry and health care. PubMed, Web of Science and Scopus databases were searched for articles containing the keywords "psychotherapy", "ethics", "therapeutic relationship" and "supervision". The search was conducted by repeating the terms in various combinations without language or time restrictions. Also included were data from monographs cited in reviews. The resulting text is a review with conclusions concerning ethical aspects of psychotherapy. The ability to behave altruistically, sense for justice and reciprocity and mutual help are likely to be genetically determined as dispositions to be later developed by upbringing or to be formed or deformed by upbringing. Early experiences lead to formation of ethical attitudes which are internalized and then applied to both one's own and other people's behavior. Altruistic behavior has a strong impact on an individual's health and its acceptance may positively influence the pathophysiological mechanisms underlying numerous diseases. Ethical theory and reflection, however, may be applied to both theory and practice of psychotherapy in a conscious, targeted and thoughtful manner. In everyday practice, psychotherapists and organizations must necessarily deal with conscious conflicts between therapeutic possibilities, clients' wishes, their own as well as clients' ideas and the real world. Understanding one's own motives in therapy is one of the aims of a

  2. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Jianting; Melchiorri, Anthony J.; Ramella-Roman, Jessica C.; Mathews, Scott A.; Coburn, James C.; Sorg, Brian S.; Chen, Yu; Joshua Pfefer, T.

    2015-12-01

    The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements-including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth-were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light-tissue interactions and characterizing biophotonic system performance.

  3. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Jianting; Melchiorri, Anthony J.; Ramella-Roman, Jessica C.; Mathews, Scott A.; Coburn, James C.; Sorg, Brian S.; Chen, Yu; Joshua Pfefer, T.

    2015-01-01

    Abstract. The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements—including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth—were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light–tissue interactions and characterizing biophotonic system performance. PMID:26662064

  4. Bragg reflection program

    International Nuclear Information System (INIS)

    Lynn, J.W.

    This user's guide to the Bragg Reflection Program (BRP) is in the nature of an informal report. The general purpose of BRP is to scan a series of Bragg reflections automatically in order to obtain profiles and integrated intensities. The program is used in conjunction with the SUPERVISOR and READ packages, and the procedures for using it are similar to those for the Triple-Axis Control program. All the general features of the system, SUPERVISOR and READ packages as described in the Spectrometer Control Systems User's Guide are preserved. The presentation assumes that the reader is familiar with these. Sections are given on the READ package, execution and use, error messages, and output. A few sample problems are shown. (1 figure) (U.S.)

  5. Reflections on Active Networking

    Science.gov (United States)

    2005-01-01

    with a Software Switch for Active Networks ”. We had initially called the project “ SoftSwitch ”, but after some concerns David Farber raised that this...Reflections on Active Networking Jonathan M. Smith CIS Department, University of Pennsylvania jms@cis.upenn.edu Abstract Interactions among...telecommunications networks , computers, and other peripheral devices have been of interest since the earliest distributed computing systems. A key

  6. Clinical linguistics: conversational reflections.

    Science.gov (United States)

    Crystal, David

    2013-04-01

    This is a report of the main points I made in an informal "conversation" with Paul Fletcher and the audience at the 14th ICPLA conference in Cork. The observations arose randomly, as part of an unstructured 1-h Q&A, so they do not provide a systematic account of the subject, but simply reflect the issues which were raised by the conference participants during that time.

  7. Superradiance or total reflection?

    CERN Document Server

    László, András

    2014-01-01

    Numerical evolution of massless scalar fields on Kerr background is studied. The initial data specifications are chosen to have compact support separated from the ergoregion and to yield nearly monochromatic incident wave packets. The initial data is also tuned to maximize the effect of superradiance. Evidences are shown indicating that instead of the anticipated energy extraction from black hole the incident radiation fail to reach the ergoregion rather it suffers a nearly perfect reflection.

  8. Simple and Rapid Quantification of Total Carotenoids in Lyophilized Apricots (Prunus armeniaca L. by Means of Reflectance Colorimetry and Photoacoustic Spectroscopy

    Directory of Open Access Journals (Sweden)

    Gitta Ficzek

    2013-01-01

    Full Text Available Photoacoustic spectroscopy (PAS and reflectance colorimetry are suggested as new tools for the analysis of total carotenoids in lyophilized apricot powders. The data obtained by these two techniques from seven apricot cultivars were compared to those acquired by spectrophotometry and high-performance liquid chromatography (HPLC. Best correlations were found between the total carotenoid (TC content (obtained by VIS spectrophotometry: 1.2–3.4 mg per 100 g of fresh mass and colorimetric index a* (a* represents the redness of the investigated sample, as well as either argon-ion laser- or xenon-lamp-based PAS. In all three cases linear correlations were comparable. However, according to the sensitivity and precision data, expressed via limit of detection (LOD and measurement repeatability, the Xe-lamp-based PAS is a preferred approach, followed by colorimetric index a* and Ar-ion laser PAS. Both PAS methods exhibit practically the same Pearson's correlation coefficient (R=0.987 and R=0.991 values. Nevertheless, residual sum of squares (RSS and residual standard deviation of the linear regression (sy/x differ markedly. For Xe-lamp-based PAS these parameters were much lower than in the case of Ar-ion laser PAS. Likewise, analysis imprecision amounted to relative standard deviation (RSD of 1–3 % for Xe-lamp PAS and 2–6 % for Ar-ion laser PAS. On the other hand, as expected, the calibration sensitivity achieved for the PAS signal induced by an Ar-ion laser at 481 nm was substantially higher than that of a Xe-lamp at 470 nm. Nevertheless, according to much lower sy/x, the corresponding LOD for Xe-lamp PAS was still two times lower than that of Ar-ion-based laser PAS (0.59 vs. 1.10 mg per 100 g. Unlike this, Ar-ion laser PAS showed more favourable instrumental precision and standard error of the weighed mean when compared to the Xe-lamp PAS (0.1–0.6 and 0.1–0.3 % vs. 0.5–8.0 and 0.4–1.7 %, respectively. As far as colorimetric indices are

  9. Integrin Signalling

    OpenAIRE

    Schelfaut, Roselien

    2005-01-01

    Integrins are receptors presented on most cells. By binding ligand they can generate signalling pathways inside the cell. Those pathways are a linkage to proteins in the cytosol. It is known that tumor cells can survive and proliferate in the absence of a solid support while normal cells need to be bound to ligand. To understand why tumour cells act that way, we first have to know how ligand-binding to integrins affect the cell. This research field includes studies on activation of proteins b...

  10. The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom

    International Nuclear Information System (INIS)

    Wolf, M.

    1999-01-01

    It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid. It acts as container for a liquid solution with Intralipid, 60 μmol l -1 haemoglobin and yeast. The solution was oxygenated using oxygen and then deoxygenated by the yeast. From the instrumental (Critikon 2020) algorithm, we found that with increasing scattering (0.5%, 1%, 1.5% and 2% Intralipid concentration) the reading was increasingly offset from the expected value of 0 μmol l -1 by 55.7, 68.6, 76.5 and 80.4 μmol l -1 (oxyhaemoglobin) and 16.0, 24.4, 29.6 and 31.7 μmol l -1 (deoxyhaemoglobin). This reduced the range of the oxygen saturation reading from the expected 100% to 31.5, 21.1, 14.3 and 11.5%. Haemoglobin concentration changes were increasingly underestimated by a factor of two to four. For a second algorithm based on the diffusion approximation the offsets were smaller: oxyhaemoglobin 11.4, 17.8, 22.5 and 25.1 μmol l -1 and deoxyhaemoglobin 1.3, 3.4, 5.2 and 6.0 μmol l -1 . The range of the oxygen saturation reading was higher: 41.3, 29.2, 23.4 and 16.6%. Concentration changes were underestimated by a factor of six to ten. This study demonstrates the need to develop algorithms which take into consideration anatomical structures. (author)

  11. Assessing Pearl Quality Using Reflectance UV-Vis Spectroscopy: Does the Same Donor Produce Consistent Pearl Quality?

    Directory of Open Access Journals (Sweden)

    Paul C. Southgate

    2010-09-01

    Full Text Available Two groups of commercial quality (“acceptable” pearls produced using two donors, and a group of “acceptable” pearls from other donors were analyzed using reflectance UV-Vis spectrophotometry. Three pearls with different colors produced by the same donor showed different absorption spectra. Cream and gold colored pearls showed a wide absorption from 320 to about 460 nm, while there was just slight reflectance around 400 nm by the white pearl with a pink overtone. Cream and gold pearls reached a reflectance peak at 560 to 590 nm, while the white pearl with pink overtone showed slightly wider absorption in this region. Both cream and gold pearls showed an absorption peak after the reflectance peak, at about 700 nm for the cream pearl and 750 nm for the gold pearl. Two other pearls produced by the same donor (white with cream overtone and cream with various overtones showed similar spectra, which differed in their intensity. One of these pearls had very high lustre and its spectrum showed a much higher percentage reflectance than the second pearl with inferior lustre. This result may indicate that reflectance is a useful quantitative indicator of pearl lustre. The spectra of two white pearls resulting from different donors with the same color nacre (silver showed a reflectance at 260 nm, followed by absorption at 280 nm and another reflectance peak at 340 nm. After this peak the spectra for these pearls remained flat until a slight absorption peak around 700 nm. Throughout the visible region, all white pearls used in this study showed similar reflectance spectra although there were differences in reflectance intensity. Unlike the spectral results from white pearls, the results from yellow and gold pearls varied according to color saturation of the pearl. The results of this study show that similarities between absorption and reflectance spectra of cultured pearls resulting from the same saibo donor are negligible and could not be detected

  12. Reflection Revisited: The Class Collage

    Science.gov (United States)

    Sommers, Jeff

    2011-01-01

    Through the regular use of what Donald Schon has termed reflection-in-action and reflection-on-action, students can learn to improve their "reflection-in-presentation," in Kathleen Blake Yancey's term. Students are often asked to do this type of reflection-in-presentation as a capstone to first-year or basic writing courses. However, a number of…

  13. Reflection as Self-Assessment

    Science.gov (United States)

    Pappas, Marjorie L.

    2010-01-01

    In this article, the author discusses how reflection can be used as self-assessment. Reflection involves not only thinking about a learning experience, but also questioning parts of the experience. Reflection is thinking about what one knows from the learning experience, what one might do differently the next time. Reflection is wondering about…

  14. Low-temperature relative reflectivity measurements of reflective and scintillating foils used in rare event searches

    Science.gov (United States)

    Langenkämper, A.; Ulrich, A.; Defay, X.; Feilitzsch, F. v.; Lanfranchi, J.-C.; Mondragón, E.; Münster, A.; Oppenheimer, C.; Potzel, W.; Roth, S.; Schönert, S.; Steiger, H.; Trinh Thi, H. H.; Wawoczny, S.; Willers, M.; Zöller, A.

    2018-03-01

    In this work we investigate the reflectivity of highly reflective multilayer polymer foils used in the CRESST experiment. The CRESST experiment searches directly for dark matter via operating scintillating CaWO4 crystals as targets for elastic dark matter-nucleon scattering. In order to suppress background events, the experiment employs the so-called phonon-light technique which is based on the simultaneous measurement of the heat signal in the main CaWO4 target crystal and of the emitted scintillation light with a separate cryogenic light detector. Both detectors are surrounded by a highly reflective and scintillating multilayer polymer foil to increase the light collection efficiency and to veto surface backgrounds. While this study is motivated by the CRESST experiment, the results are also relevant for other rare event searches using scintillating cryogenic bolometers in the field of the search of dark matter and neutrinoless double beta decay (0 νββ). In this work a dedicated experiment has been set up to determine the relative reflectivity at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti") produced by the company 3M. The intensity of a light beam reflected off the foil is measured with a CCD camera. The ratio of the intensities at 300 K and 20 K corresponds to the relative reflectivity change. The measurements performed in this work show no variation of the reflectivity with temperature at a level of ∼1%.

  15. Defects in UV-vis-NIR reflectance spectra as method for forgery detections in writing documents

    Energy Technology Data Exchange (ETDEWEB)

    Somma, F; Aloe, P; Schirripa Spagnolo, G

    2010-11-01

    Documents have taken up a very important place in our society. Frauds committed in connection with documents are not at all uncommon, and, in fact, represent a very large domain of the forensic science called 'questioned documents'. In the field of forensic examination of questioned documents, the legitimacy of an ink entry is often an essential question. A common type of forgery consists in materially altering an existing writing or adding a new writing. These changes can be characterized by means of optical spectroscopy. The aim of this work is to perform the UV-vis-NIR reflectance spectrophotometry to analyze a range of blue and black commercial ballpoint pens, in order to investigate the discriminating abilities of the different inks found on the same document.

  16. Stochastic Gabor reflectivity and acoustic impedance inversion

    Science.gov (United States)

    Hariri Naghadeh, Diako; Morley, Christopher Keith; Ferguson, Angus John

    2018-02-01

    To delineate subsurface lithology to estimate petrophysical properties of a reservoir, it is possible to use acoustic impedance (AI) which is the result of seismic inversion. To change amplitude to AI, removal of wavelet effects from the seismic signal in order to get a reflection series, and subsequently transforming those reflections to AI, is vital. To carry out seismic inversion correctly it is important to not assume that the seismic signal is stationary. However, all stationary deconvolution methods are designed following that assumption. To increase temporal resolution and interpretation ability, amplitude compensation and phase correction are inevitable. Those are pitfalls of stationary reflectivity inversion. Although stationary reflectivity inversion methods are trying to estimate reflectivity series, because of incorrect assumptions their estimations will not be correct, but may be useful. Trying to convert those reflection series to AI, also merging with the low frequency initial model, can help us. The aim of this study was to apply non-stationary deconvolution to eliminate time variant wavelet effects from the signal and to convert the estimated reflection series to the absolute AI by getting bias from well logs. To carry out this aim, stochastic Gabor inversion in the time domain was used. The Gabor transform derived the signal’s time-frequency analysis and estimated wavelet properties from different windows. Dealing with different time windows gave an ability to create a time-variant kernel matrix, which was used to remove matrix effects from seismic data. The result was a reflection series that does not follow the stationary assumption. The subsequent step was to convert those reflections to AI using well information. Synthetic and real data sets were used to show the ability of the introduced method. The results highlight that the time cost to get seismic inversion is negligible related to general Gabor inversion in the frequency domain. Also

  17. Seismic reflection imaging, accounting for primary and multiple reflections

    Science.gov (United States)

    Wapenaar, Kees; van der Neut, Joost; Thorbecke, Jan; Broggini, Filippo; Slob, Evert; Snieder, Roel

    2015-04-01

    Imaging of seismic reflection data is usually based on the assumption that the seismic response consists of primary reflections only. Multiple reflections, i.e. waves that have reflected more than once, are treated as primaries and are imaged at wrong positions. There are two classes of multiple reflections, which we will call surface-related multiples and internal multiples. Surface-related multiples are those multiples that contain at least one reflection at the earth's surface, whereas internal multiples consist of waves that have reflected only at subsurface interfaces. Surface-related multiples are the strongest, but also relatively easy to deal with because the reflecting boundary (the earth's surface) is known. Internal multiples constitute a much more difficult problem for seismic imaging, because the positions and properties of the reflecting interfaces are not known. We are developing reflection imaging methodology which deals with internal multiples. Starting with the Marchenko equation for 1D inverse scattering problems, we derived 3D Marchenko-type equations, which relate reflection data at the surface to Green's functions between virtual sources anywhere in the subsurface and receivers at the surface. Based on these equations, we derived an iterative scheme by which these Green's functions can be retrieved from the reflection data at the surface. This iterative scheme requires an estimate of the direct wave of the Green's functions in a background medium. Note that this is precisely the same information that is also required by standard reflection imaging schemes. However, unlike in standard imaging, our iterative Marchenko scheme retrieves the multiple reflections of the Green's functions from the reflection data at the surface. For this, no knowledge of the positions and properties of the reflecting interfaces is required. Once the full Green's functions are retrieved, reflection imaging can be carried out by which the primaries and multiples are

  18. In-vivo studies of reflectance pulse oximeter sensor

    Science.gov (United States)

    Ling, Jian; Takatani, Setsuo; Noon, George P.; Nose, Yukihiko

    1993-08-01

    Reflectance oximetry can offer an advantage of being applicable to any portion of the body. However, the major problem of reflectance oximetry is low pulsatile signal level which prevents prolonged clinical application during extreme situations, such as hypothermia and vasoconstriction. In order to improve the pulsatile signal level of reflectance pulse oximeter and thus its accuracy, three different sensors, with the separation distances (SPD) between light emitting diode (LED) and photodiode being 3, 5, and 7 mm respectively, were studied on nine healthy volunteers. With the increase of the SPD, it was found that both the red (660 nm) and near-infrared (830 nm) pulsatile to average signal ratio (AC/DC) increased, and the standard deviations of (AC/DC)red/(AC/DC)infrared ratio decreased, in spite of the decrease of the absolute signal level. Further clinical studies of 3 mm and 7 mm SPD sensors on seven patients also showed that the (AC/DC)red/(AC/DC)infrared ratio measured by the 7 mm sensor were less disturbed than the 3 mm sensor during the surgery. A theoretical study based on the three-dimensional photon diffusion theory supports the experimental and clinical results. As a conclusion, the 7 mm sensor has the highest signal-to- noise ratio among three different sensors. A new 7 mm SPD reflectance sensor, with the increased number of LEDs around the photodiode, was designed to increase the AC/DC ratio, as well as to increase the absolute signal level.

  19. Reflections on preventive medicine.

    Science.gov (United States)

    Miettinen, Olli S

    2014-10-01

    Having thought much about medicine in my career-long effort to understand it and the research for its advancement, I have come to views rather different form the now-prevailing ones in respect to what preventive medicine is about; what epidemiology is in relation to preventive medicine; what distinguishes preventive medicine in preventive healthcare at large; the relation of preventive medicine to public health; the concept of health promotion; and also the core principles of preventive medicine. All of these views I set forth in this article, for the readers' critical reflection. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Matter reflects Antimatter

    CERN Document Server

    Bianconi, A.; Cristiano, A.; Leali, M.; Lodi Rizzini, E.; Venturelli, L.; Zurlo, N.

    2008-01-01

    It is common belief that the interaction between antimatter and ordinary solid matter is dominated by annihilation. However, non-destructive processes may play a relevant role too. One century ago E. Rutherford wrote about the "diffuse reflection" of alpha and beta particles by thin layers of different metals: "The observations ... of Geiger and Marsden on the scattering of alpha rays indicate that some of the alpha particles must suffer a deflexion of more than a right angle at a single encounter.... It will be shown that the main deductions from the theory are independent of whether the central charge is supposed to be positive or negative". Although the theory of electromagnetic scattering is in first approximation independent of the relative sign of the colliding particles, in the case where projectile antiprotons are shot against a wall of solid matter the Rutherford diffuse reflection mechanism competes with the annihilation process. So it is not obvious at all that a relevant part of an antiproton beam...

  1. Reflection, Interrogatory, Provocation

    International Nuclear Information System (INIS)

    Carnes, W.E.

    2016-01-01

    This invited paper advances a framing context for considering next steps in HOF and organizational culture in light of the presentations and discussions that occur during the conference. Many of the contributions during the conference will represent results of scholarly research, structured investigations, or formal organizational improvement efforts. This contribution is intended as informal reflection by a 40-year nuclear veteran on themes from other presentations considering questions such as: ''Where do we think we are?, Are we better off as an industry based on what we have done?, Where do we think we need to go?, What do we think we need to do?, and, Why do we think these things?'' Our coming together on this occasion marks 30 years since the publication of INSAG-l. As we reflect on the past, perhaps it is time to pose a series of questions. Are we sustainers of a mature technology that is in some places declining and being replaced by other energy sources? If we consider nuclear a mature technology, should we focus most on operational excellence with renewed attention to managing the unexpected? Or, is innovation still a vital part of our industry?

  2. Application of neutron activation analysis and spectrophotometry for the determination of copper level in sera and cerebrospinal fluids of schizophrenic patients

    International Nuclear Information System (INIS)

    Lipcsey, A.; Fekete, J.; Oerdoegh, M.; Szabo, E.

    1985-01-01

    Neutron activation analysis and spectrophotometry were used for the determination of copper content in sera and cerebrospinal fluids of schizophrenic patients against control persons. Comparison of the results of copper determination by both methods is tabulated. From the data the following conclusions can be drawn: for copper determinations in sera the results of the two methods agree excellently. At small copper concentrations in the cerebrospinal fluids the deviations are rather high. It can also be seen that the copper contents determined from cerebrospinal fluids taken at different times are nearly equal. (author)

  3. Determination of the Np(IV)-Np(III) normal potential in fused LiCl-CsCl (55-45%) by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Lysy, R.; Duyckaerts, G.

    1977-01-01

    The following reaction Np 4+ + 1/2 H 2 + Cl - reversible Np 3+ + HCl has been studied quantitatively in fused LiCl-CsCl (55-45 mol %) in the temperature range of 450-600 0 C, by visible and near IR absorption spectrophotometry. At 450 deg C, the equilibrium constant equals K = 7.4 atmsup(1/2). The mean values of ΔH and ΔS in the temperature range of 450-600 deg C are: ΔH = (35.6+-10.3) kJ mol -1 , ΔS=(65.5+-13.0)J mol -1 K -1 [fr

  4. Interaction of the carbon monoxide-releasing molecule Ru(CO)3Cl(glycinate) (CORM-3) with Salmonella enterica serovar Typhimurium: in situ measurements of carbon monoxide binding by integrating cavity dual-beam spectrophotometry.

    Science.gov (United States)

    Rana, Namrata; McLean, Samantha; Mann, Brian E; Poole, Robert K

    2014-12-01

    Carbon monoxide (CO) is a toxic gas that binds to haems, but also plays critical signalling and cytoprotective roles in mammalian systems; despite problems associated with systemic delivery by inhalation of the gas, it may be employed therapeutically. CO delivered to cells and tissues by CO-releasing molecules (CO-RMs) has beneficial and toxic effects not mimicked by CO gas; CO-RMs are also attractive candidates as novel antimicrobial agents. Salmonella enterica serovar Typhimurium is an enteropathogen causing gastroenteritis in humans. Recent studies have implicated haem oxygenase-1 (HO-1), the protein that catalyses the degradation of haem into biliverdin, free iron and CO, in the host immune response to Salmonella infection. In several studies, CO administration via CO-RMs elicited many of the protective roles of HO-1 induction and so we investigated the effects of a well-characterized water-soluble CO-RM, Ru(CO)3Cl(glycinate) (CORM-3), on Salmonella. CORM-3 exhibits toxic effects at concentrations significantly lower than those reported to cause toxicity to RAW 264.7 macrophages. We demonstrated here, through oxyhaemoglobin assays, that CORM-3 did not release CO spontaneously in phosphate buffer, buffered minimal medium or very rich medium. CORM-3 was, however, accumulated to high levels intracellularly (as shown by inductively coupled plasma MS) and released CO inside cells. Using growing Salmonella cultures without prior concentration, we showed for the first time that sensitive dual-beam integrating cavity absorption spectrophotometry can detect directly the CO released from CORM-3 binding in real-time to haems of the bacterial electron transport chain. The toxic effects of CO-RMs suggested potential applications as adjuvants to antibiotics in antimicrobial therapy. © 2014 The Authors.

  5. A simple and efficient ultrasonic-assisted extraction procedure combined with UV-Vis spectrophotometry for the pre-concentration and determination of folic acid (vitamin B9) in various sample matrices.

    Science.gov (United States)

    Gürkan, Ramazan; Altunay, Nail

    2016-07-01

    A simple and efficient ultrasonic-assisted extraction (UAE) procedure has been proposed for the pre-concentration of (2S)-2-[(4-{[(2-amino-4-hydroxypteridin-yl)methyl]amino}phenyl)formamido]pentanedioic acid (folic acid) in vegetables, pharmaceuticals and foods prior to determination at 540 nm using UV-Vis spectrophotometry. The method is based on hydrophobic ternary complex formation of folic acid with silver ions in the presence of cetyltrimethylammonium bromide (CTAB) as a sensitivity enhancer counter ion at pH 7.0, and then extraction into a micellar phase of polyethylene glycol monoalkyl ether (Genapol X-080). The impacts on the extraction efficiency and complex formation of analytical parameters such as sample pH, concentration of silver, concentration of surfactants and extraction time, ultrasonic time and sample volume, were investigated and optimised in detail. The matrix effect on the pre-concentration and determination of folic acid was investigated, and it was observed that the proposed method was highly selective against possible matrix co-extractives. Under optimised conditions, a good linear relationship between the analytical signal and folic acid concentration was obtained in the range of 0.6-180 μg l(-1) with a detection limit of 0.19 μg l(-1) and quantification limit of 0.63 μg l(-1). The applicability was evaluated using samples fortified at different concentration levels, and recoveries higher than 94.1% were obtained. The precision as the percent relative standard deviation (RSD%) was in range of 2.5-3.8% (10 and 40 μg l(-1), n = 5). The proposed method was validated by analysis of two standard reference materials (SRMs) and various real samples, and satisfactory results were obtained.

  6. Reflection and Non-Reflection of Particle Wavepackets

    Science.gov (United States)

    Cox, Timothy; Lekner, John

    2008-01-01

    Exact closed-form solutions of the time-dependent Schrodinger equation are obtained, describing the propagation of wavepackets in the neighbourhood of a potential. Examples given include zero reflection, total reflection and partial reflection of the wavepacket, for the sech[superscript 2]x/a, 1/x[superscript 2] and delta(x) potentials,…

  7. Spectrophotometry of four H II regions in the Perseus arm and a reassessment of galactic abundance gradients

    International Nuclear Information System (INIS)

    Talent, D.L.; Dufour, R.J.

    1979-01-01

    The results from deep spectrophotometry of four Perseus arm H II regions (NGC 1624, NGC 2359, NGC 7538, and NGC 7635) obtained with the KPNO IIDS are presented. The observed line strengths are used to derive electron temperatures, densities, and the relative concentrations of H, He, N, O, S, Cl, and Ar in the nebulae. These abundances are combined with similarly derived abundances for seven other well-observed galactic H II regions, and are used to estimate the magnitude of galactic abundance gradients over the 8--14 kpc region of the solar neighborhood.Significant radial gradients for oxygen and nitrogen are found: d log (O/H)/dR=-0.059 +- 0.017 kpc -1 and d log (N/H)/dR= -0.083 +- 0.018 kpc -1 , while only marginal evidence for a helium gradient is found: d log (He/H)/dR=-0.008 +- 0.008 kpc -1 . Little evidence for gradient in S/H is found. From the red [N II] and [S II] lines we found d log (N + /S + )/dR=-0.068 +- 0.024 kpc -1 , which suggests that a radial gradient in S/O exists in the Galaxy. The O/H gradient found in this study is similar to that found from planetary nebulae, while the N/H gradient is significantly smaller. These results suggest that most of the nitrogen in the interstellar medium of the Galaxy was produced by primary nucleosynthesis processes.We also find evidence that the radial O/H and N/H gradients for H II regions in a given spiral arm are 2 to 3 times steeper than the global gradients over the 8--14 kpc interval in galactocentric distance. For four H II regions in the Sagittarius arm we found d log (O/H)/dR=-0.24 kpc -1 and d log (N/H)/dR=-0.16 kpc -1 . For five H II regions in the Perseus arm we found d log (O/H)/dR=-0.18 kpc -1 and d log (N/H)/dR=-0.15 kpc -1 . The larger magnitudes of these gradients are greater than those of the global gradients by amounts which exceed reasonable errors in abundances and/or relative distances

  8. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  9. Cross-talk in abscisic acid signaling

    Science.gov (United States)

    Fedoroff, Nina V.

    2002-01-01

    "Cross-talk" in hormone signaling reflects an organism's ability to integrate different inputs and respond appropriately, a crucial function at the heart of signaling network operation. Abscisic acid (ABA) is a plant hormone involved in bud and seed dormancy, growth regulation, leaf senescence and abscission, stomatal opening, and a variety of plant stress responses. This review summarizes what is known about ABA signaling in the control of stomatal opening and seed dormancy and provides an overview of emerging knowledge about connections between ABA, ethylene, sugar, and auxin synthesis and signaling.

  10. Reflecting Contemporary Design Research

    DEFF Research Database (Denmark)

    Engholm, Ida

    2017-01-01

    In recent years, design research has been the object of growing attention in universities and academies throughout the world. The present paper addresses the heterogeneous character of design research and the current need for reflection on the various approaches and interests. For this purpose......, the paper follows two steps. First, it proposes a categorization of the field in the form of a position model. The paper’s underlying assumption is that design research as a discipline exists in many different forms that cannot necessarily be brought together under one common academic research tradition......; instead it is necessary to attempt to define the field in order to initiate discussions about what constitutes the various research bases for design. Second, the paper discusses the implication for future design research when it is an interdisciplinary field that involves many disciplines, mindsets...

  11. The Reflective Methodologists

    DEFF Research Database (Denmark)

    Kjær, Bjørg

    2013-01-01

    In recent years, a focus on inclusion and vulnerable children has reignited discussions about the quality of pedagogical work. It has also initiated processes of change that have challenged the Danish kindergarten tradition and the identity of the pedagogue in a number of different ways. In this ......In recent years, a focus on inclusion and vulnerable children has reignited discussions about the quality of pedagogical work. It has also initiated processes of change that have challenged the Danish kindergarten tradition and the identity of the pedagogue in a number of different ways...... in which the practical sense and tacit knowledge are related to questions of power and social actors’ strategies for positioning themselves within a social space. This demands a particular focus on the historical effect of the concept of ‘the reflective practitioner’ as a symbolic marker of identity...

  12. Reflections on SLAP

    International Nuclear Information System (INIS)

    Cooke, Roger

    1997-01-01

    The SLAP data bases represent a major step forward in the reliability analysis of passive components. The present reflections are motivated by draft documentation for SLAP and have profited greatly from discussions with the SLAP team. We collect a number of remarks and suggestions: The use of event and failure fields to organize the data seems sensible and feasible, from a data analysis viewpoint. Influence factors, i. e. environmental influences which are affected by plant operations, are clearly important yet very difficult to accommodate in any straightforward data analysis methodology. We would welcome a serious effort to estimate the exposure in the various exposure cells. These estimates would not be based on failure records, but on knowledge of plant design and operations. Quantitative expert judgement might be a viable alternative to a massive review of all plants in the SLAP data base

  13. Reflections on Conformal Spectra

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    We use modular invariance and crossing symmetry of conformal field theory to reveal approximate reflection symmetries in the spectral decompositions of the partition function in two dimensions in the limit of large central charge and of the four-point function in any dimension in the limit of large scaling dimensions Δ0 of external operators. We use these symmetries to motivate universal upper bounds on the spectrum and the operator product expansion coefficients, which we then derive by independent techniques. Some of the bounds for four-point functions are valid for finite Δ0 as well as for large Δ0. We discuss a similar symmetry in a large spacetime dimension limit. Finally, we comment on the analogue of the Cardy formula and sparse light spectrum condition for the four-point function. (based on 1510.08772 with Kim & Ooguri). This seminar will be given via videolink

  14. Reflections on academic video

    Directory of Open Access Journals (Sweden)

    Thommy Eriksson

    2012-11-01

    Full Text Available As academics we study, research and teach audiovisual media, yet rarely disseminate and mediate through it. Today, developments in production technologies have enabled academic researchers to create videos and mediate audiovisually. In academia it is taken for granted that everyone can write a text. Is it now time to assume that everyone can make a video essay? Using the online journal of academic videos Audiovisual Thinking and the videos published in it as a case study, this article seeks to reflect on the emergence and legacy of academic audiovisual dissemination. Anchoring academic video and audiovisual dissemination of knowledge in two critical traditions, documentary theory and semiotics, we will argue that academic video is in fact already present in a variety of academic disciplines, and that academic audiovisual essays are bringing trends and developments that have long been part of academic discourse to their logical conclusion.

  15. Reflections on Student Persistence

    Directory of Open Access Journals (Sweden)

    Vincent Tinto

    2017-07-01

    Full Text Available The Feature for this issue Reflections on Student Persistence has been prepared by Professor Vincent Tinto, Distinguished University Professor Emeritus at Syracuse University, United States of America (USA and a longtime friend and supporter of STARS. Vincent explores the case for motivation to be considered as a significant aspect of the tertiary student psyche by drawing on theoretical frameworks, research and practical experiences related to the issue. He synthesises this extensive, detailed, rich but often somewhat impenetrable data into a trilogy of clear and credible key dimensions of the motivation construct student self efficacy, sense of belonging and perceived value of the curriculum. This interpretation of the literature is a personal but informed reflection and is a timely piece which highlights the breadth and profundity of the presentations at this year's conference in Adelaide, Australia where students in all their diversity are central to our focus on enhancing the student experience. In this opening article, Vincent refers directly to the STARS papers selected for this Conference issue of the Journal which also address the importance of student persistence, self-efficacy and building the sense of belonging within their own institutional communities (Fernandes, Ford, Rayner & Pretorius; Kahu, Nelson, & Picton; McFarlane, Spes-Skrbis & Taib; Naylor; Smallhorn. Echoing his position on social justice and his advocacy for underserved students, Vincent reminds us that educational equity gaps still exist, and he encourages us to see the issue of persistence through the eyes of the students to support their perseverance and completion and thereby help reduce educational disadvantage.

  16. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  17. Spectrophotometry of carbon stars

    International Nuclear Information System (INIS)

    Gow, C.E.

    1975-01-01

    Observations of over one hundred carbon stars have been made with the Indiana rapid spectral scanner in the red and, when possible, in the visual and blue regions of the spectrum. Five distinct subtypes of carbon stars (Barium, CH, R, N, and hydrogen deficient) are represented in the list of observed stars, although the emphasis was placed on the N stars when the observations were made. The rapid scanner was operated in the continuous sweep mode with the exit slit set at twenty angstroms, however, seeing fluctuations and guiding errors smear the spectrum to an effective resolution of approximately thirty angstroms. Nightly observations of Hayes standard stars yielded corrections for atmospheric extinction and instrumental response. The reduction scheme rests on two assumptions, that thin clouds are gray absorbers and the wavelength dependence of the sky transparency does not change during the course of the night. Several stars have been observed in the blue region of the spectrum with the Indiana SIT vidicon spectrometer at two angstroms resolution. It is possible to derive a color temperature for the yellow--red spectral region by fitting a black-body curve through two chosen continuum points. Photometric indices were calculated relative to the blackbody curve to measure the C 2 Swan band strength, the shape of the CN red (6,1) band to provide a measure of the 12 C/ 13 C isotope ratio, and in the hot carbon stars (Barium, CH, and R stars) the strength of an unidentified feature centered at 400 angstroms. An extensive abundance grid of model atmospheres was calculated using a modified version of the computer code ATLAS

  18. Spectrophotometry of carbon stars

    Energy Technology Data Exchange (ETDEWEB)

    Oganesyan, R.K.; Karapetyan, M.S.; Nersisyan, S.E.

    1986-01-01

    The results are given of the spectrophotometric investigation of 56 carbon stars in the spectral range from 4000 to 6800 A with resolution 3 A. The observed energy distributions of these stars are determined relative to the flux at the wavelength /sub 0/ = 5556; they are presented in the form of graphs. The energy distributions have been obtained for the first time for 35 stars. Variation in the line Ba II 4554 A has been found in the spectra of St Cam, UU Aur, and RV Mon. Large changes have taken place in the spectra of RT UMa and SS Vir. It is noted that the spectra of carbon stars have a depression, this being situated in different spectral regions for individual groups of stars.

  19. Reflective Practices for Teacher Education

    Directory of Open Access Journals (Sweden)

    Paulus Kuswandono

    2017-01-01

    Full Text Available Studies on reflective practice in teacher education are increasingly getting more attention at least in the last 2 decades. This article discusses concepts of reflection and how it is implemented in educating pre-service teachers on their early stage of professional learning. The purposes of doing the reflection for pre-service teachers are not only for illuminating their professional learning experiences, but also to critically reflect their vocation as teachers, including the values which may be dictated to them through rigid regulations. Reflection in teacher education is crucial as it connects well with learning in that learners use reflection to exercise their mind and to evaluate their learning experiences. Besides, this article also highlights some perceived difficulties to implement reflective practice, as well as ways how to promote reflection.   DOI: https://doi.org/10.24071/llt.2012.150102

  20. What Makes a Good Trader? On the Role of Intuition and Reflection on Trader Performance

    OpenAIRE

    Corgnet, Brice; Desantis, Mark; Porter, David

    2016-01-01

    Using simulations and experiments, we pinpoint two main drivers of trader performance: cognitive reflection and theory of mind. Both dimensions facilitate traders' learning about asset valuation. Cognitive reflection helps traders use market signals to update their beliefs whereas theory of mind offers traders crucial hints on the quality of those signals. We show these skills to be complementary because traders benefit from understanding the quality of market signals only if they are capable...

  1. Guided and Unguided Student Reflections

    OpenAIRE

    Matheson, Amanda; Wood, Laura; Franklin, Scott V.

    2017-01-01

    Self-reflection is important metacognitive skill, enabling students to build coherence into their learning and embed content in a broader context. While various pedagogical techniques exist to encourage student reflection, little research has examined the differences between formally guided, partially guided and unguided reflections. This study focuses on student responses to online Guided Reflection Forms (GRFs) from students in a first-semester non-physics class and, separately, a sophomore...

  2. Students’ Learning through Reflective Journaling

    OpenAIRE

    Alvyda Liuolienė; Regina Metiūnienė

    2011-01-01

    The aim of the article is to get acquainted with the types of journals used in education to help students to learn. The paper presents some ways of fostering student’s learning through reflective journaling. It also describes the key aspects of a new method ARRIVE cycle in connection with teachers preparation to use reflective journals in a classroom. The article also presents self-assessment in reflective journaling and students’ need to self-evaluate their learning process. Reflective journ...

  3. Reflection in Russian Educational Psychology.

    Science.gov (United States)

    Nelissen, Jo M. C.; Tomic, Welko

    This paper discusses the cultural-historical school founded by Vygotsky, Luria, and Leontiev as the theoretical background of Russian educational psychologists who have been studying how children learn to reflect. Two approaches to reflection are examined within the cultural-historical tradition: first, reflection--like other higher psychological…

  4. Reflective Practice: Origins and Interpretations

    Science.gov (United States)

    Reynolds, Michael

    2011-01-01

    The idea of reflection is central to the theory and practice of learning--especially learning which is grounded in past or current experience. This paper proposes a working definition of reflection and reviews its origins and recent developments. The author also provides an account of "critical reflection", including its rationale and…

  5. Total internal reflection tomography of small objects

    International Nuclear Information System (INIS)

    Chen Xudong

    2008-01-01

    The multiple signal classification (MUSIC) imaging method is applied to determine the locations of a collection of small anisotropic spherical scatterers in the framework of the total internal reflection tomography. Multiple scattering between scatterers is considered and the inverse scattering problem is nonlinear, which, however, is solved by the proposed fast analytical approach where no associated forward problem is iteratively evaluated. The paper also discusses the role of the polarization of incidence waves, the incidence angle, the separation of scatterers from the surface of the substrate, and the level of noise on the resolution of imaging.

  6. Sensing And Force-Reflecting Exoskeleton

    Science.gov (United States)

    Eberman, Brian; Fontana, Richard; Marcus, Beth

    1993-01-01

    Sensing and force-reflecting exoskeleton (SAFiRE) provides control signals to robot hand and force feedback from robot hand to human operator. Operator makes robot hand touch objects gently and manipulates them finely without exerting excessive forces. Device attaches to operator's hand; comfortable and lightweight. Includes finger exoskeleton, cable mechanical transmission, two dc servomotors, partial thumb exoskeleton, harness, amplifier box, two computer circuit boards, and software. Transduces motion of index finger and thumb. Video monitor of associated computer displays image corresponding to motion.

  7. Coherent reflectivity using white synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Panzner, Tobias; Sant, Tushar; Pietsch, Ullrich [Universitaet Siegen (Germany). Festkoerperphysik

    2008-07-01

    Using coherent white synchrotron radiation in the hard X-ray region for reflectivity experiments one have access to sample properties on a nanometer scale in principle. To extract the wanted information from the performed measurements so called phase retrieval algorithms are necessary. The authors developed a straight forward simulation program based on a spatial limited atomic flat surface to evaluate the influence of different parameters on the coherent scattered signal in the detector plane. These simulations can explain some interesting features of the measurements and shows unexpected results for the influence of the so called illumination function.

  8. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters.

    Science.gov (United States)

    Santos, Inês C; Mesquita, Raquel B R; Rangel, António O S S

    2015-09-03

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60-160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11-21 for the metal ions. A LOD of 0.23 μg L(-1) for cadmium, 2.39 μg L(-1) for zinc, and 0.11 μg L(-1) for copper and a sampling rate of 12, 13, and 15 h(-1) for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters

    International Nuclear Information System (INIS)

    Santos, Inês C.; Mesquita, Raquel B.R.; Rangel, António O.S.S.

    2015-01-01

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60–160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11–21 for the metal ions. A LOD of 0.23 μg L"−"1 for cadmium, 2.39 μg L"−"1 for zinc, and 0.11 μg L"−"1 for copper and a sampling rate of 12, 13, and 15 h"−"1 for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. - Highlights: • Multi-parametric determination of cadmium, zinc, and copper at the μg L"−"1 level. • In-line metal ions preconcentration using NTA resin. • Minimization of matrix interferences by performing solid phase spectrometry in a SI-LOV platform. • Successful application to metal ions determination in freshwaters.

  10. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    Science.gov (United States)

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Teachers’ way of reflecting

    DEFF Research Database (Denmark)

    Lund, Lea

    2016-01-01

    This paper contributes to insights on teachers’ thinking and practice by building partly on the large amount of prior research in the field of continuing professional development (in line with ISATT), and partly on examples from an empirical small-scale study executed in Denmark. The purpose of t......’ reflections on practice. Based on this model, the paper provides a proposal regarding how to work with teachers’ professional development and learning processes. Educational implications and future research directions are discussed.......This paper contributes to insights on teachers’ thinking and practice by building partly on the large amount of prior research in the field of continuing professional development (in line with ISATT), and partly on examples from an empirical small-scale study executed in Denmark. The purpose...... of the Danish study was to investigate and understand teachers’ classroom experiences using Fenstermacher’s approach to develop a practical argument, as these classroom experiences are regarded as a potential source of learning for teachers. A three-level scale model from the study describes the teach-ers...

  12. Spin analysis and new effects in reflectivity measurements

    International Nuclear Information System (INIS)

    Fermon, C.

    1996-01-01

    We present two new effects in polarized neutron reflectivity. We show that we have a non symmetric spin-flip signal in reflectivity measurements on magnetic films when the external field is not negligible. This phenomenon is due to different Larmor precessions for the two spin states and has to be taken into account in some experiments. The second effect is still not understood but we present results indicating that the specular reflection on a non magnetic surface can induce a neutron beam depolarization or rotation. (authors)

  13. A Biosensor for Urea from Succinimide-Modified Acrylic Microspheres Based on Reflectance Transduction

    Directory of Open Access Journals (Sweden)

    Musa Ahmad

    2011-08-01

    Full Text Available New acrylic microspheres were synthesised by photopolymerisation where the succinimide functional group was incorporated during the microsphere preparation. An optical biosensor for urea based on reflectance transduction with a large linear response range to urea was successfully developed using this material. The biosensor utilized succinimide-modified acrylic microspheres immobilized with a Nile blue chromoionophore (ETH 5294 for optical detection and urease enzyme was immobilized on the surface of the microspheres via the succinimide groups. No leaching of the enzyme or chromoionophore was observed. Hydrolysis of the urea by urease changes the pH and leads to a color change of the immobilized chromoionophore. When the color change was monitored by reflectance spectrophotometry, the linear response range of the biosensor to urea was from 0.01 to 1,000 mM (R2 = 0.97 with a limit of detection of 9.97 mM. The biosensor response showed good reproducibility (relative standard deviation = 1.43%, n = 5 with no interference by major cations such as Na+, K+, NH4+ and Mg2+. The use of reflectance as a transduction method led to a large linear response range that is better than that of many urea biosensors based on other optical transduction methods.

  14. High reflectivity YDH/SiO2 distributed Bragg reflector for UV-C wavelength regime

    KAUST Repository

    Alias, Mohd Sharizal

    2018-02-15

    A distributed Bragg reflector (DBR) composed of Y2O3-doped HfO2 (YDH)/SiO2 layers with high reflectivity spectrum centered at a wavelength of ~240 nm is deposited using radio-frequency magnetron sputtering. Before the DBR deposition, optical properties for a single layer of YDH, SiO2, and HfO2 thin films were studied using spectroscopic ellipsometry and spectrophotometry. To investigate the performance of YDH as a material for the high refractive index layer in the DBR, a comparison of its optical properties was made with HfO2 thin films. Due to larger optical bandgap, the YDH thin films demonstrated higher transparency, lower extinction coefficient, and lower absorption coefficient in the UV-C regime (especially for wavelengths below 250 nm) compared to the HfO2 thin films. The deposited YDH/SiO2 DBR consisting of 15 periods achieved a reflectivity higher than 99.9% at the wavelength of ~240 nm with a stopband of ~50 nm. The high reflectivity and broad stopband of YDH/SiO2 DBRs will enable further advancement of various photonic devices such as vertical-cavity surface-emitting lasers, resonant-cavity light-emitting diodes, and resonant-cavity photodetectors operating in the UV-C wavelength regime.

  15. Arterial wave reflection decreases gradually from supine to upright

    DEFF Research Database (Denmark)

    van den Bogaard, Bas; Westerhof, Berend E; Best, Hendrik

    2011-01-01

    BACKGROUND. An increase in total peripheral resistance (TPR) usually increases arterial wave reflection. During passive head-up tilt (HUT), however, arterial wave reflection decreases with increasing TPR. This study addressed whether arterial wave reflection gradually decreases during HUT. METHODS....... In 10 healthy volunteers (22-39 years, nine males), we recorded finger arterial pressures in supine position (0°), and 30°and 70°degrees HUT and active standing (90°). Aortic pressure was constructed from the finger pressure signal and hemodynamics were calculated. Arterial wave reflection...... from 0.9 dyn s/cm(5) at 0? to 1.2, 1.4 and 1.4 dyn s/cm(5) at 30°, 70° and 90° (p wave reflection...

  16. Price signals in the power market

    International Nuclear Information System (INIS)

    2000-01-01

    Which price signals should be given to the players in the power market to promote a socio-economic power supply in the short term and the long term? In a model with perfect competition, without problems involving delivery quality, and with free scalable capacity in both transmission and production, price signals that reflect marginal losses and shortage of transmission capacity are all that is needed. Stepwise investments create a need for measures that are specific to the situation. Price signals reflecting delivery reliability are probably too weak today. Market power may create a need for greater transmission capacity, but gives no reason for new price signals. Tariffs that reduce installed capacity weakens delivery quality and increases the probability of market power

  17. Speciation of inorganic antimony in polyethylene terephthalate (PET) bottled water using hydride generation atomic absorption spectrophotometry (HG-AAS)

    International Nuclear Information System (INIS)

    Markwo, Ali

    2015-07-01

    Antimony (Sb) is a regulated drinking water contaminant that has been found to leach from polyethylene terephthalate (PET) plastic containers into the waters stored in them. The common inorganic species of antimony in water are Sb(III) and Sb(V), with the former being more toxic and the latter being more soluble. In order to assess the extent to which waters stored in PET bottles are contaminated with inorganic Sb and to further examine the effect of typical storage conditions on migration rates, speciation analysis of inorganic Sb using hydride generation atomic absorption spectrophotometry (HG-AAS) was undertaken on selected PET plastic bottled waters marketed in the Greater Accra Region of Ghana. Six brands of PET plastic bottled waters were obtained at source on the day of packaging, and analyses undertaken on samples of the waters stored in the plastic containers at intervals of four weeks for twelve weeks, under three carefully chosen storage conditions distinctive of bottled water usage. Selected physicochemical properties of samples of the waters stored in the plastic containers and total Sb of samples of the plastic containers were also determined to discover the effect of some physical properties and certain major ions, and the influence of the different quality PET plastic types on Sb migration respectively. The study revealed amounts of total Sb in the PET plastic containers of the 6 brands ranging from 123.46 mg/kg to 146.45 mg/kg. The selected physicochemical properties of the waters stored in the PET plastic containers considered were pH (6.78 – 7.43), Ca2+ (1.61 – 12.39 mg/L), Mg2+ (1.00 – 4.96 mg/L), HCO3− (6.18 – 55.41 mg/L) and TDS (8.70 – 70.40 mg/L)). PET bottled waters of 5 out of the 6 brands contained Sb (initial total Sb ranging from 1.11 – 14.65 μg/L) before storage. Total Sb concentrations of the waters stored in the plastic containers were observed to increase with storage time under all the three storage conditions for

  18. Effect of reflective practice education on self-reflection, insight, and reflective thinking among experienced nurses: a pilot study.

    Science.gov (United States)

    Asselin, Marilyn E; Fain, James A

    2013-01-01

    A mixed-method study was conducted to determine whether nurses' participation in a reflective practice continuing education program using a structured reflection model makes a difference in nurses' self-reflection, insight, and reflective thinking about clinical practice situations. Findings suggested that use of structured reflection using question cues, written narratives, and peer-facilitated reflection increased nurses' engagement in self-reflection and enhanced reflective thinking in practice. Including reflective practice education in novice orientation and preceptor training may be beneficial.

  19. Demystifying the reflective clinical journal

    International Nuclear Information System (INIS)

    Milinkovic, Danielle; Field, Nikki

    2005-01-01

    Student learning on clinical placement is a complex issue and cannot be defined solely by just doing things. Reflection during clinical practice is essential if the student is going to learn from the experience. Therefore it is important for educators to include as part of clinical education programs learning strategies that encourage reflection. The reflective clinical journal is an educational tool that is employed by the School of Medical Radiation Sciences at the University of Sydney to encourage reflection of undergraduate radiation therapy students whilst on clinical placement. This discussion paper explores the key concepts of reflection and the reflective clinical journal. Due to the paucity of information about this issue in radiation therapy the literature reviewed is from across all areas of the health sciences

  20. Extreme Ultraviolet Bragg mirrors with suppressed infrared reflectivity properties

    NARCIS (Netherlands)

    Medvedev, Viacheslav; Yakshin, Andrey; Louis, Eric; van de Kruijs, Robbert Wilhelmus Elisabeth; van den Boogaard, Toine; Krivtsun, V.M.; Yakinun, A.M.; Bijkerk, Frederik

    2013-01-01

    Many optical applications demand high reflectivity in a particular wavelength range while simultaneously requiring suppression of radiation outside this range. Such parasitic radiation can for instance lead to image distortions in imaging applications or poor signal-noise ratios in spectroscopy. The

  1. Extreme Ultraviolet Bragg mirrors with suppressed infrared reflectivity properties

    NARCIS (Netherlands)

    Medvedev, Viacheslav; Yakshin, Andrey; Louis, Eric; van de Kruijs, Robbert Wilhelmus Elisabeth; van den Boogaard, Toine; Krivtsun, V.M.; Yakunin, A.M.; Bijkerk, Frederik

    2012-01-01

    Many optical applications demand high reflectivity in a particular wavelength range while simultaneously requiring suppression of radiation outside this range. Such parasitic radiation can for instance lead to image distortions in imaging applications or poor signal-noise ratios in spectroscopy. The

  2. Berlin Reflectance Spectral Library (BRSL)

    Science.gov (United States)

    Henckel, D.; Arnold, G.; Kappel, D.; Moroz, L. V.; Markus, K.

    2017-09-01

    The Berlin Reflectance Spectral Library (BRSL) provides a collection of reflectance spectra between 0.3 and 17 µm. It was originally dedicated to support space missions to small solar system bodies. Meanwhile the library includes selections of biconical reflectance spectra for spectral data analysis of other planetary bodies as well. The library provides reference spectra of well-characterized terrestrial analogue materials and meteorites for interpretation of remote sensing reflectance spectra of planetary surfaces. We introduce the BRSL, summarize the data available, and access to use them for further relevant applications.

  3. Students’ Learning through Reflective Journaling

    Directory of Open Access Journals (Sweden)

    Alvyda Liuolienė

    2011-04-01

    Full Text Available The aim of the article is to get acquainted with the types of journals used in education to help students to learn. The paper presents some ways of fostering student’s learning through reflective journaling. It also describes the key aspects of a new method ARRIVE cycle in connection with teachers preparation to use reflective journals in a classroom. The article also presents self-assessment in reflective journaling and students’ need to self-evaluate their learning process. Reflective journaling as central to students’ self-evaluation is described as a means of fostering metacognition.

  4. Studies of the Reflection, Refraction and Internal Reflection of Light

    Science.gov (United States)

    Lanchester, P. C.

    2014-01-01

    An inexpensive apparatus and associated experiments are described for studying the basic laws of reflection and refraction of light at an air-glass interface, and multiple internal reflections within a glass block. In order to motivate students and encourage their active participation, a novel technique is described for determining the refractive…

  5. Cultivating Reflective Practitioners in Technology Preparation: Constructing TPACK through Reflection

    Directory of Open Access Journals (Sweden)

    Liangyue Lu

    2013-12-01

    Full Text Available Teaching is a complex profession, which is further complicated by the integration of technology into classrooms. Reflection can help teachers unpack the complexity in their practice. Reflection can be an effective instructional strategy in helping preservice teachers develop technological pedagogical content knowledge (TPACK, the complex and dynamic knowledge necessary for effective technology integration into instruction. In this study, reflective activities were integrated into a Learning By Design (LBD environment, which was created to help preservice teachers develop TPACK. This paper investigated the participants’ TPACK development and examined how reflection helped them construct TPACK. Through content analysis of the participants’ reflective journals, the researcher found that the preservice teachers developed initial TPACK awareness. However, their reflection in technology knowledge and the content aspects of TPACK were limited and superficial. Interviews with the participants showed reflection helped the preservice teachers remember what they learned by describing and elaborating on their in-class experiences, pushed them to think about how to apply what they learned in their future classrooms, and helped them become more reflective and open-minded about using technology in classrooms. Finally, the researcher discussed this study’s implications for teacher educators and researchers.

  6. Reflection and Reflective Practice Discourses in Coaching: A Critical Analysis

    Science.gov (United States)

    Cushion, Christopher J.

    2018-01-01

    Reflection and reflective practice is seen as an established part of coaching and coach education practice. It has become a "taken-for-granted" part of coaching that is accepted enthusiastically and unquestioningly, and is assumed to be "good" for coaching and coaches. Drawing on sociological concepts, a primarily Foucauldian…

  7. Postgraduate Education to Support Organisation Change: A Reflection on Reflection

    Science.gov (United States)

    Stewart, Jim; Keegan, Anne; Stevens, Pam

    2008-01-01

    Purpose: This paper aims to explore how teaching and assessing reflective learning skills can support postgraduate practitioners studying organisational change and explores the challenges for tutors in assessing these journals. Design/methodology/approach: Assessment criteria were developed from the literature on reflective practice and…

  8. Rock Sparrow Song Reflects Male Age and Reproductive Success

    DEFF Research Database (Denmark)

    Nemeth, Erwin; Kempenaers, Bart; Matessi, Giuliano

    2012-01-01

    The evolution of mating signals is closely linked to sexual selection. Acoustic ornaments are often used as secondary sexual traits that signal the quality of the signaller. Here we show that song performance reflects age and reproductive success in the rock sparrow (Petronia petronia...... nests. Older males could be distinguished from yearlings by singing at lower rate and higher amplitudes. Our findings suggest that song rate may be used as a signal of age and together with song pitch as a signal of reproductive success in this species. Alternatively, younger and less successful males...... success. Males with higher breeding success sang at a lower rate and with a higher maximum frequency. We found also that older males gained more extra-pair young and had a higher overall breeding success, although they also differed almost significantly by having a higher loss of paternity in their own...

  9. Ultraviolet signals in birds are special.

    Science.gov (United States)

    Hausmann, Franziska; Arnold, Kathryn E; Marshall, N Justin; Owens, Ian P F

    2003-01-07

    Recent behavioural experiments have shown that birds use ultraviolet (UV)-reflective and fluorescent plumage as cues in mate choice. It remains controversial, however, whether such UV signals play a special role in sexual communication, or whether they are part of general plumage coloration. We use a comparative approach to test for a general association between sexual signalling and either UV-reflective or fluorescent plumage. Among the species surveyed, 72% have UV colours and there is a significant positive association between UV reflectance and courtship displays. Among parrots (Psittaciformes), 68% of surveyed species have fluorescent plumage, and again there is a strong positive association between courtship displays and fluorescence. These associations are not artefacts of the plumage used in courtship displays, being generally more 'colourful' because there is no association between display and colours lacking UV reflectance or fluorescence. Equally, these associations are not phylogenetic artefacts because all results remain unchanged when families or genera, rather than species, are used as independent data points. We also find that, in parrots, fluorescent plumage is usually found adjacent to UV-reflective plumage. Using a simple visual model to examine one parrot, the budgerigar Melopsittacus undulatus, we show that the juxtaposition of UV-reflective and fluorescent plumage leads to a 25-fold increase in chromatic contrast to the budgerigar's visual system. Taken together, these results suggest that signals based on UV contrast are of special importance in the context of active sexual displays. We review briefly six hypotheses on why this may be the case: suitability for short-range signalling; high contrast with backgrounds; invisibility to predators; exploitation of pre-existing sensory biases; advertisement of feather structure; and amplification of behavioural signals.

  10. Ubuntu feminism: Tentative reflections

    Directory of Open Access Journals (Sweden)

    Drucilla Cornell

    2015-06-01

    Full Text Available The starting-point for the article is to provide a brief background on the Ubuntu Project that Prof. Drucilla Cornell convened in 2003; most notably the interviews conducted in Khayamandi, the support of a sewing collective, and the continued search to launch an Ubuntu Women�s Centre. The article will reflect on some of the philosophical underpinnings of ubuntu, whereafter debates in Western feminism will be revisited. Ubuntu feminism is suggested as a possible response to these types of feminisms. The authors support an understanding of ubuntu as critique and ubuntu feminism accordingly as a critical intervention that recalls a politics of refusal. The article ends by raising the importance of thinking about spatiality through ubuntu, and vice versa. It may seem strange to title an article Ubuntu feminism when feminism itself has often been identified as a European or Western idea. But, this article will argue that ubuntu offers conceptions of transindividuality and ways of social belonging that could respond in a meaningful way to some of European feminism�s own dilemmas and contradictions. Famously, one of the most intense debates in feminism was between those who defended an ethic of care in a relational view of the self, on one side, and those feminists who held on to more traditional conceptions of justice, placing an emphasis on individuality and autonomy, on the other side. The authors will suggest that ubuntu could address this tension in feminism. Thus, in this article the focus will not simply be on ubuntu, in order to recognise that there are other intellectual heritages worthy of consideration, other than those in Europe and the United States. It will also take a next step in arguing that ubuntu may be a better standpoint entirely from which to continue thinking about what it means to be a human being, as well as how to conceive of the integral interconnection human beings all have with one another. This connection through

  11. Ocean color remote sensing using polarization properties of reflected sunlight

    Science.gov (United States)

    Frouin, R.; Pouliquen, E.; Breon, F.-M.

    1994-01-01

    The effects of the atmosphere and surface on sunlight backscattered to space by the ocean may be substantially reduced by using the unpolarized component of reflectance instead of total reflectance. At 450 nm, a wavelength of interest in ocean color remote sensing, and for typical conditions, 45% of the unpolarized reflectance may originate from the water body instead of 20% of the total reflectance, which represents a gain of a factor 2.2 in useful signal for water composition retrieval. The best viewing geometries are adjacent to the glitter region; they correspond to scattering angles around 100 deg, but they may change slightly depending on the polarization characteristics of the aerosols. As aerosol optical thickness increases, the atmosphere becomes less efficient at polarizing sunlight, and the enhancement of the water body contribution to unpolarized reflectance is reduced. Since the perturbing effects are smaller on unpolarized reflectance, at least for some viewing geometries, they may be more easily corrected, leading to a more accurate water-leaving signal and, therefore, more accurate estimates of phytoplankton pigment concentration.

  12. Thermal consequences of colour and near-infrared reflectance.

    Science.gov (United States)

    Stuart-Fox, Devi; Newton, Elizabeth; Clusella-Trullas, Susana

    2017-07-05

    The importance of colour for temperature regulation in animals remains controversial. Colour can affect an animal's temperature because all else being equal, dark surfaces absorb more solar energy than do light surfaces, and that energy is converted into heat. However, in reality, the relationship between colour and thermoregulation is complex and varied because it depends on environmental conditions and the physical properties, behaviour and physiology of the animal. Furthermore, the thermal effects of colour depend as much on absorptance of near-infrared ((NIR), 700-2500 nm) as visible (300-700 nm) wavelengths of direct sunlight; yet the NIR is very rarely considered or measured. The few available data on NIR reflectance in animals indicate that the visible reflectance is often a poor predictor of NIR reflectance. Adaptive variation in animal coloration (visible reflectance) reflects a compromise between multiple competing functions such as camouflage, signalling and thermoregulation. By contrast, adaptive variation in NIR reflectance should primarily reflect thermoregulatory requirements because animal visual systems are generally insensitive to NIR wavelengths. Here, we assess evidence and identify key research questions regarding the thermoregulatory function of animal coloration, and specifically consider evidence for adaptive variation in NIR reflectance.This article is part of the themed issue 'Animal coloration: production, perception, function and application'. © 2017 The Author(s).

  13. Spectrophotometry of peculiar B and A stars. XVII. 63 Andromedae, HD 34452, epsilon Ursae Majoris, CQ Ursae Majoris, CU Virginis, CS Virginis and Beta Coronae Borealis

    International Nuclear Information System (INIS)

    Pyper, D.M.; Adelman, S.J.

    1985-01-01

    Optical region spectrophotometry results are presented for seven Ap stars. Additional data for two silicon stars, HD 34452 and CU Vir, show that both have energy distributions that can be fit by a single global model atmosphere, except for the lambda 4200 and lambda 5200 broad absorption features. These features are strong in HD 34452 and show no evidence of variation, while they are weak in CU Vir but show clear evidence of variations. The energy distributions of the five cooler Ap stars cannot be fit by a single model atmosphere. CQ UMa, CS Vir and β CrB all show complicated variations with phase at different wavelengths. Their energy distributions show combined effects of flux redistribution and differential line blanketing. Except for epsilon UMa, none of these five stars show evidence of variations of the lambda 4200 or lambda 5200 broad absorption features

  14. Spectrophotometry of peculiar B and A stars. XVIII - The helium rich variable stars HR 1890, Sigma Orionis E, and HD 37776

    Science.gov (United States)

    Adelman, S. J.; Pyper, D. M.

    1985-01-01

    Optical region spectrophotometry at 3300-7850 A has been obtained for three helium rich stars, HR 1890, Sigma Ori E, and HD 37776, of the Orion OB1 Association. New uvby-beta photometry of HR 1890 and HD 37776 as well as published data are also used to investigate the variability of these stars. A new period of 1.53862 days was determined for HD 37776. For all three stars H-beta varies in antiphase with strong He I lines. The spectrophotometric bandpass containing the strong He I line at 4471 A varies in phase with the R index of Pedersen and Thomsen (1977). Evidence is found for weak absorption features which appear to be an extension of the 5200 A feature seen in cooler CP stars.

  15. Comparative study between derivative spectrophotometry and multivariate calibration as analytical tools applied for the simultaneous quantitation of Amlodipine, Valsartan and Hydrochlorothiazide.

    Science.gov (United States)

    Darwish, Hany W; Hassan, Said A; Salem, Maissa Y; El-Zeany, Badr A

    2013-09-01

    Four simple, accurate and specific methods were developed and validated for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in commercial tablets. The derivative spectrophotometric methods include Derivative Ratio Zero Crossing (DRZC) and Double Divisor Ratio Spectra-Derivative Spectrophotometry (DDRS-DS) methods, while the multivariate calibrations used are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods were applied successfully in the determination of the drugs in laboratory-prepared mixtures and in commercial pharmaceutical preparations. The validity of the proposed methods was assessed using the standard addition technique. The linearity of the proposed methods is investigated in the range of 2-32, 4-44 and 2-20 μg/mL for AML, VAL and HCT, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Simultaneous determination of benznidazole and itraconazole using spectrophotometry applied to the analysis of mixture: A tool for quality control in the development of formulations.

    Science.gov (United States)

    Pinho, Ludmila A G; Sá-Barreto, Lívia C L; Infante, Carlos M C; Cunha-Filho, Marcílio S S

    2016-04-15

    The aim of this work was the development of an analytical procedure using spectrophotometry for simultaneous determination of benznidazole (BNZ) and itraconazole (ITZ) in a medicine used for the treatment of Chagas disease. In order to achieve this goal, the analysis of mixtures was performed applying the Lambert-Beer law through the absorbances of BNZ and ITZ in the wavelengths 259 and 321 nm, respectively. Diverse tests were carried out for development and validation of the method, which proved to be selective, robust, linear, and precise. The lower limits of detection and quantification demonstrate its sensitivity to quantify small amounts of analytes, enabling its application for various analytical purposes, such as dissolution test and routine assays. In short, the quantification of BNZ and ITZ by analysis of mixtures had shown to be efficient and cost-effective alternative for determination of these drugs in a pharmaceutical dosage form. Copyright © 2016. Published by Elsevier B.V.

  17. Simultaneous determination of benznidazole and itraconazole using spectrophotometry applied to the analysis of mixture: A tool for quality control in the development of formulations

    Science.gov (United States)

    Pinho, Ludmila A. G.; Sá-Barreto, Lívia C. L.; Infante, Carlos M. C.; Cunha-Filho, Marcílio S. S.

    2016-04-01

    The aim of this work was the development of an analytical procedure using spectrophotometry for simultaneous determination of benznidazole (BNZ) and itraconazole (ITZ) in a medicine used for the treatment of Chagas disease. In order to achieve this goal, the analysis of mixtures was performed applying the Lambert-Beer law through the absorbances of BNZ and ITZ in the wavelengths 259 and 321 nm, respectively. Diverse tests were carried out for development and validation of the method, which proved to be selective, robust, linear, and precise. The lower limits of detection and quantification demonstrate its sensitivity to quantify small amounts of analytes, enabling its application for various analytical purposes, such as dissolution test and routine assays. In short, the quantification of BNZ and ITZ by analysis of mixtures had shown to be efficient and cost-effective alternative for determination of these drugs in a pharmaceutical dosage form.

  18. High-throughput screening assay used in pharmacognosy: Selection, optimization and validation of methods of enzymatic inhibition by UV-visible spectrophotometry

    Directory of Open Access Journals (Sweden)

    Graciela Granados-Guzmán

    2014-02-01

    Full Text Available In research laboratories of both organic synthesis and extraction of natural products, every day a lot of products that can potentially introduce some biological activity are obtained. Therefore it is necessary to have in vitro assays, which provide reliable information for further evaluation in in vivo systems. From this point of view, in recent years has intensified the use of high-throughput screening assays. Such trials should be optimized and validated for accurate and precise results, i.e. reliable. The present review addresses the steps needed to develop and validate bioanalytical methods, emphasizing UV-Visible spectrophotometry as detection system. Particularly focuses on the selection of the method, the optimization to determine the best experimental conditions, validation, implementation of optimized and validated method to real samples, and finally maintenance and possible transfer it to a new laboratory.

  19. Monitoring Pb in Aqueous Samples by Using Low Density Solvent on Air-Assisted Dispersive Liquid-Liquid Microextraction Coupled with UV-Vis Spectrophotometry.

    Science.gov (United States)

    Nejad, Mina Ghasemi; Faraji, Hakim; Moghimi, Ali

    2017-04-01

    In this study, AA-DLLME combined with UV-Vis spectrophotometry was developed for pre-concentration, microextraction and determination of lead in aqueous samples. Optimization of the independent variables was carried out according to chemometric methods in three steps. According to the screening and optimization study, 86 μL of 1-undecanol (extracting solvent), 12 times syringe pumps, pH 2.0, 0.00% of salt and 0.1% DDTP (chelating agent) were chosen as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R = 0.9994, and linearity range was 0.01-100 µg mL -1 . LOD and LOQ were 3.4 and 11.6 ng mL -1 , respectively. The method was applied for analysis of real water samples, such as tap, mineral, river and waste water.

  20. Comparative study between derivative spectrophotometry and multivariate calibration as analytical tools applied for the simultaneous quantitation of Amlodipine, Valsartan and Hydrochlorothiazide

    Science.gov (United States)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeany, Badr A.

    2013-09-01

    Four simple, accurate and specific methods were developed and validated for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in commercial tablets. The derivative spectrophotometric methods include Derivative Ratio Zero Crossing (DRZC) and Double Divisor Ratio Spectra-Derivative Spectrophotometry (DDRS-DS) methods, while the multivariate calibrations used are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods were applied successfully in the determination of the drugs in laboratory-prepared mixtures and in commercial pharmaceutical preparations. The validity of the proposed methods was assessed using the standard addition technique. The linearity of the proposed methods is investigated in the range of 2-32, 4-44 and 2-20 μg/mL for AML, VAL and HCT, respectively.

  1. Separation of Cu, In, Fe and Sn from nuclear grade thorium by tri-n-octyl amine-5 M HCI and their determination by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Moraes, S. de; Cipriani, M.; Abrao, A.

    1976-01-01

    The results of solvent extraction separation of a group of metal traces in high pure thorium with the aid of tri-n-octyl amine-benzene from ThCL 4 HCI are summarized. ThCl 4 HCI-KI solutions Cu,In,Fe and Sn are extracted together and determined by atomic absoprtion spectrophotometry, burning directly the organic phase. The behavior of Cu,In,Fe and Sn toward direct burn of the organic phase using hydrogen-air mixture was studied, and an absorption enhancement was observed. The procedure is being used ot perform the quality control of nuclear grade thorium and its compounds. The calibration curves have provided precisions in the range 1 to 10% in analysis of thorium

  2. Diagnosis of soils polluted by aromatic hydrocarbons; Diagnostic de sols pollues par des hydrocarbures aromatiques polycycliques (HAP) a l'aide de la spectrophotometrie UV

    Energy Technology Data Exchange (ETDEWEB)

    Crone, M

    2000-01-28

    Polycyclic aromatic hydrocarbons (PAHs) were produced by many pyrolytic or combustion processes. They were found in soils, often in high concentrations. Remediation of industrial sites contaminated by PAHs requires an initial diagnosis of the pollution. In this perspective, an analytical procedure based on UV spectrophotometry was developed and validated with about 80 soil samples. Different exploitation methods of the samples UV spectra enable to develop simple and rapid characterisation tools. A PAH UV index is proposed for the estimation of global PAH concentration. A more accurate exploitation of the spectra gives an indication on the presence or the absence of some individual PAH like benzo[a]pyrene. A maturity index based on a two wavelength approach constitutes an indicator of the potential evolution of soil contamination in natural conditions. Laboratory methodology was adapted to field analyses and a test kit was designed for this purpose. The test duration is 20 minutes. (author)

  3. SEM/EDX and vis spectrophotometry study of the stability of resin-bound mortars used for casting replicas and filling missing parts of historic stone fountains.

    Science.gov (United States)

    Roig-Salom, José-Luis; Doménech-Carbó, María-Teresa; de la Cruz-Cañizares, Juana; Bolívar-Galiano, Fernando; Pelufo-Carbonell, María-José; Peraza-Zurita, Yaiza

    2003-04-01

    A study by SEM/EDX and spectrophotometry in the visible region attempting to assess the stability of new resin-bound mortars used for casting replicas of marble historic fountains is presented in this paper. Different accelerating tests such as thermal ageing, UV light ageing, ageing in an SO(2) pollutant chamber, freezing cycles ageing, salt crystallisation ageing, natural ageing and biological attack have been applied to a series of test specimens prepared with polyester-, epoxy- and gel-coat-bound mortars. Examination of morphology, measurement of chemical composition and chromatic coordinates before and after ageing treatments establish the higher stability and resistance properties of these resin-bound mortars by comparison to those from the natural marbles.

  4. Study for the determination of samarium, europium,terbium, dysprosium and yttrium in gadolinium oxide matrix by means of atomic absorption spectrophotometry using a graphite furnace

    International Nuclear Information System (INIS)

    Caires, A.C.F.

    1985-01-01

    A study for determination of samarium, europium, terbium, dysprosium and yttrium in a gadolinium oxide matrix by atomic absorption spectrophotometry using a graphite furnace is presented. The best charrring and atomization conditions were estabilished for each element, the most convenient ressonance lines being selected as well. The study was carried out for the mentioned lanthanides both when pure and when in binary mixtures with gadolinium, besides those where all for them were together with gadolinium. The determination limits for pure lanthanides were found to be between 1.3 and 9.6 ng assuming a 20% relative standard deviation as acceptable. The detection limits were in the range 0.51 and 7.5 ng, assuming as positive any answer higher than twofold the standard deviation. (author) [pt

  5. Separation of Cu, In, Fe and Sn from nuclear grade thorium by tri-n-octyl amine--5 M HCI and their determination by atomic absorption spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    de Moraes, S; Cipriani, M; Abrao, A

    1976-03-01

    The results of solvent extraction separation of a group of metal traces in high pure thorium with the aid of tri-n-octyl amine-benzene from ThCl/sub 4/HCl are summarized. ThCl/sub 4/HCl-KI solutions of Cu, In, Fe and Sn are extracted together and determined by atomic absoprtion spectrophotometry and burning directly the organic phase. The behavior of Cu, In, Fe and Sn toward direct burn of the organic phase using hydrogen-air mixture was studied, and an absorption enhancement was observed. The procedure is being used to perform the quality control of nuclear grade thorium and its compounds. The calibration curves have provided precisions in the range 1 to 10% in analysis of thorium.

  6. Diagnosis of soils polluted by aromatic hydrocarbons; Diagnostic de sols pollues par des hydrocarbures aromatiques polycycliques (HAP) a l'aide de la spectrophotometrie UV

    Energy Technology Data Exchange (ETDEWEB)

    Crone, M.

    2000-01-28

    Polycyclic aromatic hydrocarbons (PAHs) were produced by many pyrolytic or combustion processes. They were found in soils, often in high concentrations. Remediation of industrial sites contaminated by PAHs requires an initial diagnosis of the pollution. In this perspective, an analytical procedure based on UV spectrophotometry was developed and validated with about 80 soil samples. Different exploitation methods of the samples UV spectra enable to develop simple and rapid characterisation tools. A PAH UV index is proposed for the estimation of global PAH concentration. A more accurate exploitation of the spectra gives an indication on the presence or the absence of some individual PAH like benzo[a]pyrene. A maturity index based on a two wavelength approach constitutes an indicator of the potential evolution of soil contamination in natural conditions. Laboratory methodology was adapted to field analyses and a test kit was designed for this purpose. The test duration is 20 minutes. (author)

  7. Evaluation of the acidity constants of the 4-hidroxy-5-6salicylideneamino9-2-7-naphthalenedisulfonic acid (Azomethine-H) using UV?vis spectrophotometry

    Science.gov (United States)

    Alarcón-Angeles, G.; Corona-Avendaño, S.; Rojas-Hernández, A.; Romero-Romo, M. A.; Ramírez-Silva, M. T.

    2005-01-01

    The time stability of the azomethine-H species was determined not to be better than 10 min in the absence of oxygen and light, however under phosphate buffered conditions the azomethine-H species remained stable for longer periods, as indicated by the spectrophotometric behaviour. Nevertheless, the analysis time still exceeded the stability allowance. Therefore, the determination of the acidity constants of the Azomethine-H species was studied by means of UV-vis spectrophotometry in buffered media by means of the point-by-point analysis and data processing with SQUAD to refine the resulting constants, which were: p Ka1=3.39, p Ka2 7.36 and p Ka3 8.73. The latter were associated to the corresponding acid-base equilibria of the amine and hydroxy groups constituting the molecule.

  8. Ethical Reflections on Becoming Teachers

    Science.gov (United States)

    Joseph, Pamela Bolotin

    2016-01-01

    This study analyzes narratives written in a culminating graduate seminar on reflective practice by 36 new secondary teachers who were asked to consider their moral beliefs, moral values and system of ethics as they reflected on their recent student teaching experiences. The findings explore how the participants depicted their constructed moral…

  9. Flexible Bistable Cholesteric Reflective Displays

    Science.gov (United States)

    Yang, Deng-Ke

    2006-03-01

    Cholesteric liquid crystals (ChLCs) exhibit two stable states at zero field condition-the reflecting planar state and the nonreflecting focal conic state. ChLCs are an excellent candidate for inexpensive and rugged electronic books and papers. This paper will review the display cell structure,materials and drive schemes for flexible bistable cholesteric (Ch) reflective displays.

  10. Basic digital signal processing

    CERN Document Server

    Lockhart, Gordon B

    1985-01-01

    Basic Digital Signal Processing describes the principles of digital signal processing and experiments with BASIC programs involving the fast Fourier theorem (FFT). The book reviews the fundamentals of the BASIC program, continuous and discrete time signals including analog signals, Fourier analysis, discrete Fourier transform, signal energy, power. The text also explains digital signal processing involving digital filters, linear time-variant systems, discrete time unit impulse, discrete-time convolution, and the alternative structure for second order infinite impulse response (IIR) sections.

  11. Reflection measurements for luminescent powders

    Science.gov (United States)

    Kroon, R. E.

    2018-04-01

    Luminescent materials are useful in applications varying from lighting and display technologies to document security features and medical research, amongst many others. Measurement of the excitation range is an important consideration, and absorption bands are often determined from a decrease in the measured diffuse reflectance of the material using a ultraviolet-visible (UV-vis) spectrophotometer with an integrating sphere. Such a system may provide questionable results when used to measure the reflectance of a luminescence material, which is demonstrated for a Tb doped silica phosphor, because the system cannot differentiate between the reflected light and luminescence. It is shown that more reliable results are achieved for this phosphor by measuring the reflectance using a synchronous zero-offset scan in a fluorescence spectrometer equipped with an integrating sphere. This method is therefore recommended instead of traditional reflectance measurements using a UV-vis spectrophotometer for luminescent powders.

  12. White LEDs as broad spectrum light sources for spectrophotometry: demonstration in the visible spectrum range in a diode-array spectrophotometric detector.

    Science.gov (United States)

    Piasecki, Tomasz; Breadmore, Michael C; Macka, Mirek

    2010-11-01

    Although traditional lamps, such as deuterium lamps, are suitable for bench-top instrumentation, their compatibility with the requirements of modern miniaturized instrumentation is limited. This study investigates the option of utilizing solid-state light source technology, namely white LEDs, as a broad band spectrum source for spectrophotometry. Several white light LEDs of both RGB and white phosphorus have been characterized in terms of their emission spectra and energy output and a white phosphorus Luxeon LED was then chosen for demonstration as a light source for visible-spectrum spectrophotometry conducted in CE. The Luxeon LED was fixed onto the base of a dismounted deuterium (D(2) ) lamp so that the light-emitting spot was geometrically positioned exactly where the light-emitting spot of the original D(2) lamp is placed. In this manner, the detector of a commercial CE instrument equipped with a DAD was not modified in any way. As the detector hardware and electronics remained the same, the change of the deuterium lamp for the Luxeon white LED allowed a direct comparison of their performances. Several anionic dyes as model analytes with absorption maxima between 450 and 600 nm were separated by CE in an electrolyte of 0.01 mol/L sodium tetraborate. The absorbance baseline noise as the key parameter was 5 × lower for the white LED lamp, showing clearly superior performance to the deuterium lamp in the available, i.e. visible part of the spectrum. Copyright © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Inês C. [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal); Mesquita, Raquel B.R. [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal); Laboratório de Hidrobiologia, Instituto de Ciências Biomédicas Abel Salazar (ICBAS), Universidade do Porto, Rua de Jorge Viterbo Ferreira no. 228, 4050-313 Porto (Portugal); Rangel, António O.S.S., E-mail: arangel@porto.ucp.pt [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal)

    2015-09-03

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60–160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11–21 for the metal ions. A LOD of 0.23 μg L{sup −1} for cadmium, 2.39 μg L{sup −1} for zinc, and 0.11 μg L{sup −1} for copper and a sampling rate of 12, 13, and 15 h{sup −1} for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. - Highlights: • Multi-parametric determination of cadmium, zinc, and copper at the μg L{sup −1} level. • In-line metal ions preconcentration using NTA resin. • Minimization of matrix interferences by performing solid phase spectrometry in a SI-LOV platform. • Successful application to metal ions determination in freshwaters.

  14. Combination of rice husk and coconut shell activated adsorbent to adsorb Pb(II) ionic metal and it’s analysis using solid-phase spectrophotometry (sps)

    Science.gov (United States)

    Rohmah, D. N.; Saputro, S.; Masykuri, M.; Mahardiani, L.

    2018-03-01

    The purpose of this research was to know the effect and determine the mass comparation which most effective combination between rice husk and coconut shell activated adsorbent to adsorb Pb (II) ion using SPS method. This research used experimental method. Technique to collecting this datas of this research is carried out by several stages, which are: (1) carbonization of rice husk and coconut shell adsorbent using muffle furnace at a temperature of 350°C for an hour; (2) activation of the rice husk and coconut shell adsorbent using NaOH 1N and ZnCl2 15% activator; (3) contacting the adsorbent of rice husk and coconut shell activated adsorbent with liquid waste simulation of Pb(II) using variation comparison of rice husk and coconut shell, 1:0; 0:1; 1:1; 2:1; 1:2; (4) analysis of Pb(II) using Solid-Phase Spectrophotometry (SPS); (5) characterization of combination rice husk and coconut shell activated adsorbent using FTIR. The result of this research show that the combined effect of combination rice husk and coconut shell activated adsorbent can increase the ability of the adsorbent to absorb Pb(II) ion then the optimum adsorbent mass ratio required for absorbing 20 mL of Pb(II) ion with a concentration of 49.99 µg/L is a ratio of 2:1 with the absorption level of 97,06%Solid-Phase Spectrophotometry (SPS) is an effective method in the level of µg/L, be marked with the Limit of Detection (LOD) of 0.03 µg/L.

  15. A novel UV-photolysis approach with acetone and isopropyl alcohol for the rapid determination of fluoride in organofluorine-containing drugs by spectrophotometry.

    Science.gov (United States)

    Mullapudi, Venkata Balarama Krishna; Dheram, Karunasagar

    2018-01-01

    A UV photolysis decomposition (UVPD) method for the determination of fluoride in fluorine containing pharmaceuticals by spectrophotometry is reported. It is based on the use of high intensity UV-irradiation in the presence of a digesting solution comprising a mixture of acetone and isopropanol. For the optimization of the UVPD procedure, three bulk drugs (levofloxacin, nebivolol and efavirenz) were chosen as representatives of three diverse compounds containing a single fluorine atom, two fluorine atoms, and trifluoromethyl groups respectively. Operational conditions of the UVPD method, such as concentration and volume of reagents (acetone and isopropyl alcohol), and UV irradiation time (1-6 minutes) were optimized. The efficiency of digestion was evaluated by the determination of fluoride in sample digests. Using the developed method, it was possible for complete conversion of the organofluoride to free fluoride ion for its subsequent determination by spectrophotometry based on bleaching of Zr-xylenol orange-color complex. Quantitative recovery (>98%) of the fluorine in the drug samples could be achieved using a mixture of 2% acetone + 2% isopropyl alcohol + 0.003% Na 2 CO 3 in just 5 minutes of UV irradiation, which can be considered an important aspect considering the difficulties involved in the cleavage of the CF bond. Accuracy was evaluated by comparison of results obtained by the UVPD method with the values estimated using formula weight of the compound and no statistical difference was observed between the results. Therefore, the proposed method is suitable for application in routine analysis of fluoride in organofluorine-containing drugs. Copyright © 2016. Published by Elsevier B.V.

  16. Net Analyte Signal Standard Additions Method for Simultaneous Determination of Sulfamethoxazole and Trimethoprim in Pharmaceutical Formulations and Biological Fluids

    Directory of Open Access Journals (Sweden)

    M. H. Givianrad

    2012-01-01

    Full Text Available The applicability of a novel net analyte signal standard addition method (NASSAM to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim was verified by UV-visible spectrophotometry. The results confirmed that the net analyte signal standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. Moreover, applying the net analyte signal standard additions method revealed that the two drugs could be determined simultaneously with the concentration ratios of sulfamethoxazole to trimethoprim varying from 1:35 to 60:1 in the mixed samples. In addition, the limits of detections were 0.26 and 0.23 μmol L-1 for sulfamethoxazole and trimethoprim, respectively. The proposed method has been effectively applied to the simultaneous determination of sulfamethoxazole and trimethoprim in some synthetic, pharmaceutical formulation and biological fluid samples.

  17. Weak signal detection: A discrete window of opportunity for ...

    African Journals Online (AJOL)

    weak signal detection' as a potential opportunity to fill this void. Method: Combining futures and complexity theory, we reflect on two pilot case studies that involved the Archetype Extraction technique and the SenseMakerw CollectorTM tool.

  18. Analysis of Satellite-Based Navigation Signal Reflectometry: Simulations and Observations

    DEFF Research Database (Denmark)

    von Benzon, Hans-Henrik; Høeg, Per; Durgonics, Tibor

    2016-01-01

    on different ocean characteristics. The spectra of the simulated surface reflections are analyzed, and the results from the simulations are compared to measured GPS surface reflections. The measurements were performed using a space-qualified GPS receiver placed on a mountain at the Haleakala observatory...... on the Hawaiian island of Maui. The GPS receiver was during the experiments running in an open-loop configuration. The analysis of both the simulated surface-reflection signals and the measured reflection signals will in general reveal spectral structures of the reflected signals that can lead to extraction...

  19. Analysis of the reflection of a micro drop fiber sensor

    Science.gov (United States)

    Sun, Weimin; Liu, Qiang; Zhao, Lei; Li, Yingjuan; Yuan, Libo

    2005-01-01

    Micro drop fiber sensors are effective tools for measuring characters of liquids. These types of sensors are wildly used in biotechnology, beverage and food markets. For a fiber micro drop sensor, the signal of the output light is wavy with two peaks, normally. Carefully analyzing the wavy process can identify the liquid components. Understanding the reason of forming this wavy signal is important to design a suitable sensing head and to choose a suitable signal-processing method. The dripping process of a type of liquids is relative to the characters of the liquid and the shape of the sensing head. The quasi-Gauss model of the light field from the input-fiber end is used to analyse the distribution of the light field in the liquid drop. In addition, considering the characters of the liquid to be measured, the dripping process of the optical signal from the output-fiber end can be expected. The reflection surface of the micro drop varies as serials of spheres with different radiuses and global centers. The intensity of the reflection light changes with the shape of the surface. The varying process of the intensity relates to the tense, refractive index, transmission et al. To support the analyse above, an experimental system is established. In the system, LED is chosen as the light source and the PIN transform the light signal to the electrical signal, which is collected by a data acquisition card. An on-line testing system is made to check the theory discussed above.

  20. Plasma density fluctuation measurements from coherent and incoherent microwave reflection

    International Nuclear Information System (INIS)

    Conway, G.D.; Schott, L.; Hirose, A.

    1996-01-01

    Using the spatial coherency present in a reflected microwave signal (Conway et al 1994 Rev. Sci. Instrum. 65 2920) it is possible to measure a coherent, Γ c , and an incoherent, Γ i , reflection coefficient (proportional to the radar cross section) from a turbulent plasma cutoff layer. Results acquired with a 17 GHz reflectometer from a STOR-M tokamak edge region (r/a ∼ 0.8) give significant Γ c and Γ i , which suggests two-dimensional structure in the reflection layer. Using a 'distorted-mirror' model for the plasma fluctuations, estimates of an effective radial width, σ, and poloidal correlation length, L p , can be derived from the reflection coefficients. STOR-M results typically give a σ of a few millimetres and an L p of a couple of centimetres. (author)